WorldWideScience

Sample records for endovascular patch welding

  1. Modeling of endovascular patch welding using the computer program LATIS

    International Nuclear Information System (INIS)

    Glinsky, M.E.; London, R.A.; Zimmerman, G.B.; Jacques, S.L.

    1995-01-01

    A new computer program, LATIS, being developed at Lawrence Livermore National Laboratory is used to study the effect of pulsed laser irradiation on endovascular patch welding. Various physical and biophysical effects are included in these simulations: laser light scattering and absorption, tissue heating and heat conduction, vascular cooling, and tissue thermal damage. The geometry of a patch being held against the inner vessel wall (500 μm inner diameter) by a balloon is considered. The system is exposed to light pulsed from an optical fiber inside the balloon. A minimum in the depth of damage into the vessel wall is found. The minimum damage zone is about the thickness of the patch material that is heated by the laser. The more ordered the tissue the thinner the minimum zone of damage. The pulse length which minimizes the zone of damage is found to be the time for energy to diffuse across the layer. The delay time between the pulses is determined by the time for the heated layer to cool down. An optimal pulse length exists which minimizes the total time needed to weld the patch to the wall while keeping the thickness of the damaged tissue to less than 100 μm. For the case that is considered, a patch dyed with light absorbing ICG on the side next to the vessel (thickness of the dyed layer is 60 μm), the best protocol is found to be 65-200 ms pulses applied over 2 min

  2. Dye-enhanced protein solders and patches in laser-assisted tissue welding.

    Science.gov (United States)

    Small, W; Heredia, N J; Maitland, D J; Da Silva, L B; Matthews, D L

    1997-01-01

    This study examines the use of dye-enhanced protein bonding agents in 805 nm diode laser-assisted tissue welding. A comparison of an albumin liquid solder and collagen solid-matrix patches used to repair arteriotomies in an in vitro porcine model is presented. Extrinsic bonding media in the form of solders and patches have been used to enhance the practice of laser tissue welding. Preferential absorption of the laser wavelength has been achieved by the incorporation of chromophores. Both the solder and the patch included indocyanine green dye (ICG) to absorb the 805 nm continuous-wave diode laser light used to perform the welds. Solder-mediated welds were divided into two groups (high power/short exposure and low power/long exposure), and the patches were divided into three thickness groups ranging from 0.1 to 1.3 mm. The power used to activate the patches was constant, but the exposure time was increased with patch thickness. Burst pressure results indicated that solder-mediated and patched welds yielded similar average burst strengths in most cases, but the patches provided a higher success rate (i.e., more often exceeded 150 mmHg) and were more consistent (i.e., smaller standard deviation) than the solder. The strongest welds were obtained using 1.0-1.3 mm thick patches, while the high power/short exposure solder group was the weakest. Though the solder and patches yielded similar acute weld strengths, the solid-matrix patches facilitated the welding process and provided consistently strong welds. The material properties of the extrinsic agents influenced their performance.

  3. Experimental and computational laser tissue welding using a protein patch.

    Science.gov (United States)

    Small, W; Heredia, N J; Maitland, D J; Eder, D C; Celliers, P M; Da Silva, L B; London, R A; Matthews, D L

    1998-01-01

    An in vitro study of laser tissue welding mediated with a dye-enhanced protein patch was conducted. Fresh sections of porcine aorta were used for the experiments. Arteriotomies were treated using an indocyanine green dye-enhanced collagen patch activated by an 805-nm continuous-wave fiber-delivered diode laser. Temperature histories of the surface of the weld site were obtained using a hollow glass optical fiber-based two-color infrared thermometer. The experimental effort was complemented by simulations with the LATIS (LAser-TISsue) computer code, which uses coupled Monte Carlo, thermal transport, and mass transport models. Comparison of simulated and experimental thermal data indicated that evaporative cooling clamped the surface temperature of the weld site below 100 °C. For fluences of approximately 200 J/cm2, peak surface temperatures averaged 74°C and acute burst strengths consistently exceeded 0.14×106 dyn/cm (hoop tension). The combination of experimental and simulation results showed that the inclusion of water transport and evaporative losses in the computer code has a significant impact on the thermal distributions and hydration levels throughout the tissue volume. The solid-matrix protein patch provided a means of controllable energy delivery and yielded consistently strong welds. © 1998 Society of Photo-Optical Instrumentation Engineers.

  4. In vivo experimental study on laser welded ICG-loaded chitosan patches for vessel repair

    Science.gov (United States)

    Rossi, Francesca; Matteini, Paolo; Esposito, Giuseppe; Albanese, Alessio; Puca, Alfredo; Maira, Giulio; Rossi, Giacomo; Pini, Roberto

    2011-03-01

    Laser welding of microvessels provides several advantages over conventional suturing techniques: surgical times reduction, vascular healing process improvement, tissue damage reduction. We present the first application of biopolymeric patches in an in vivo laser assisted procedure for vessel repair. The study was performed in 20 New Zealand rabbits. After anesthesia, a 3-cm segment of the right common carotid artery was exposed and clamped proximally and distally. A linear lesion 3 mm in length was carried out. We used a diode laser emitting at 810 nm and equipped with a 300 μm diameter optical fiber. To close the cut, ICG-loaded chitosan films were prepared: chitosan is characterized by biodegradability, biocompatibility, antimicrobial, haemostatic and wound healing-promoting activity. ICG is an organic chromophore commonly used in the laser welding procedures to mediate the photothermal conversion at the basis of the welding effect. The membranes were used to wrap the whole length of the cut, and then they were welded in the correct position by delivering single laser spots to induce local patch/tissue adhesion. The result is an immediate closure of the wound, with no bleeding at clamps release. The animals were observed during follow-up and sacrificed after 2, 7, 30 and 90 days. All the repaired vessels were patent, no bleeding signs were documented. The carotid samples underwent histological examinations. The advantages of the proposed technique are: simplification of the surgical procedure and shortening of the operative time; good strength of the vessel repair; decreased foreign-body reaction, reduced inflammatory response and improved vascular healing process.

  5. Endovascular treatment of false-aneurysm ten years after dacron patch aortoplasty for coarctation of the aortic isthmus. Report of a case.

    Science.gov (United States)

    Illuminati, Giulio; Pacilè, Maria Antonietta; Palumbo, Piergaspare; Salvatori, Filippo Maria; Vietri, Francesco

    2013-01-01

    False aneurysm degeneration is a known complication of patch aortoplasty for coarctation of the aortic isthmus. Open surgical treatment consists of prosthetic graft repair of the involved aorta, often requires circulatory arrest to achieve a safe proximal aortic control and perform proximal anastomosis, and finally is associated with substantial perioperative morbidity. Endografting of the diseased aorta is a valuable alternative to open repair, when feasible, with good short and long term results. We now report one more case of false aneurysm ten years after Dacron patch aortoplasty for isthmic coarctation in a 26-year-old woman, successfully treated by endovascular repair via the left common iliac artery, and a complete exclusion of the aneurysm at two year follow-up.

  6. Suprarenal fixation barbs can induce renal artery occlusion in endovascular aortic aneurysm repair.

    Science.gov (United States)

    Subedi, Shree K; Lee, Andy M; Landis, Gregg S

    2010-01-01

    Renal artery occlusion following endovascular abdominal aortic aneurysm repair with suprarenal fixation is uncommon. We report one patient who was found to develop renal artery occlusion and parenchymal infarction 6 months after repair using an endovascular graft with suprarenal fixation. Our patient underwent emergent endovascular repair of a symptomatic 6 cm abdominal aortic aneurysm. The covered portion of the endograft was inadvertently deployed well below the renal artery orifices. At the completion of the procedure both renal arteries were confirmed to be patent. One month postoperatively, a computed tomographic (CT) scan showed exclusion of the aortic sac and normal enhancement of both kidneys. At 6 months, the patient was found to have elevated serum creatinine levels despite having no clinical symptoms. CT scanning revealed a nonenhancing left kidney, and angiography demonstrated an occlusion of the left renal artery. A barb welded to the bare metal stent appeared to be impinging on the renal artery. We believe that renal artery occlusion after endovascular repair can occur due to repetitive injury to the renal artery orifice from barbs welded to the bare metal stent. To our knowledge, this is the first reported case of renal artery occlusion caused by repetitive injury from transrenal fixation systems. Copyright 2010 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  7. Sutureless closure of scleral wounds in animal models by the use of laser welded biocompatible patches

    Science.gov (United States)

    Rossi, Francesca; Matteini, Paolo; Menabuoni, Luca; Lenzetti, Ivo; Pini, Roberto

    2011-03-01

    The common procedures used to seal the scleral or conjunctival injuries are based on the traditional suturing techniques, that may induce foreign body reaction during the follow up, with subsequent inflammation and distress for the patient. In this work we present an experimental study on the laser welding of biocompatible patches onto ocular tissues, for the closure of surgical or trauma wounds. The study was performed ex vivo in animal models (porcine eyes). A penetrating perforation of the ocular tissue was performed with a surgical knife. The wound walls were approximated, and a biocompatible patch was put onto the outer surface of the tissue, in order to completely cover the wound as a plaster. The patches were prepared with a biocompatible and biodegradable polymer, showing high mechanical strength, good elasticity, high permeability for vapour and gases and rather low biodegradation. During preparation, Indocyanine Green (ICG) was included in the biopolymeric matrix, so that the films presented high absorption at 810 nm. Effective adhesion of the membranes to the ocular tissues was obtained by using diode laser light emitted from an 810 nm diode laser and delivered by means of a 300 μm core diameter optical fiber, to produce spots of local film/tissue adhesion, due to the photothermal effect at the interface. The result is an immediate closure of the wound, thus reducing post-operative complications due to inflammation.

  8. The preparation of teaching simulation system of endovascular intervention

    International Nuclear Information System (INIS)

    Li Yiming; Wang Jie; Shi Haibin; Jin Xijun

    2011-01-01

    Objective: To establish a teaching simulation system of endovascular intervention and to evaluate its application in clinical teaching practice. Methods: The vascular model, which had quite similar diameter and length to that of human arteries, was prepared with glass tubes of different diameters. Stainless steel tubes were cut and welded to manufacture the brackets of an operation bed and a C-arm, and then the above parts together with flat were assembled into the operation bed module. Fixed camera, computer and footswitch were assembled into the image module. The above three modules were integrated into the teaching simulation system of endovascular intervention. With the help of this system, the principal endovascular intervention manipulations were imitatively exercised. Results: The vascular model had the same proportions as in normal human subjects. The operation bed module could be moved in two dimensions. The image module could capture multiple and differently formatted images as well as dynamic images in different sizes. Also, this system carried the image-frozen function, which was just the same as last image hold function of DSA. This simulation system could imitate the basic manipulations of many kinds of endovascular interventions, such as the hepatic artery catheterization, carotid artery catheterization, the performing of looping-technique in uterine artery, etc. Conclusion: The simulation system can imitate many principal endovascular manipulations, and can distinctly display the relationship of the vascular anatomy and interventional instruments with their imaging shadows. Therefore, this simulation system has a promising prospect of being able to be used in the clinical teaching program concerning vascular interventional manipulations. (authors)

  9. A new technique for the closure of the lens capsule by laser welding.

    Science.gov (United States)

    Pini, Roberto; Rossi, Francesca; Menabuoni, Luca; Lenzetti, Ivo; Yoo, Sonia; Parel, Jean-Marie

    2008-01-01

    A new method is presented for the closure of the lens capsule based on laser welding of suitably prepared patches of anterior capsular tissue. Experiments were performed in freshly enucleated porcine eyes. The patches were previously stained with a solution of indocyanine green in sterile water and then welded on the recipient capsule by means of diode laser radiation at 810 nm. The welded tissue revealed mechanical properties comparable to those of healthy tissue. This technique is proposed to repair capsular breaks and to provide the closure of the capsulorhexis in lens refilling procedures.

  10. In vivo laser assisted end-to-end anastomosis with ICG-infused chitosan patches

    Science.gov (United States)

    Rossi, Francesca; Matteini, Paolo; Esposito, Giuseppe; Scerrati, Alba; Albanese, Alessio; Puca, Alfredo; Maira, Giulio; Rossi, Giacomo; Pini, Roberto

    2011-07-01

    Laser assisted vascular repair is a new optimized technique based on the use of ICG-infused chitosan patch to close a vessel wound, with or even without few supporting single stitches. We present an in vivo experimental study on an innovative end-to-end laser assisted vascular anastomotic (LAVA) technique, performed with the application of ICGinfused chitosan patches. The photostability and the mechanical properties of ICG-infused chitosan films were preliminary measured. The in vivo study was performed in 10 New Zealand rabbits. After anesthesia, a 3-cm segment of the right common carotid artery was exposed, thus clamped proximally and distally. The artery was then interrupted by means of a full thickness cut. Three single microsutures were used to approximate the two vessel edges. The ICG-infused chitosan patch was rolled all over the anastomotic site and welded by the use of a diode laser emitting at 810 nm and equipped with a 300 μm diameter optical fiber. Welding was obtained by delivering single laser spots to induce local patch/tissue adhesion. The result was an immediate closure of the anastomosis, with no bleeding at clamps release. Thus animals underwent different follow-up periods, in order to evaluate the welded vessels over time. At follow-up examinations, all the anastomoses were patent and no bleeding signs were documented. Samples of welded vessels underwent histological examinations. Results showed that this technique offer several advantages over conventional suturing methods: simplification of the surgical procedure, shortening of the operative time, better re-endothelization and optimal vascular healing process.

  11. Radiation-Induced Alopecia after Endovascular Embolization under Fluoroscopy

    Directory of Open Access Journals (Sweden)

    Vipawee Ounsakul

    2016-01-01

    Full Text Available Radiation-induced alopecia after fluoroscopically guided procedures is becoming more common due to an increasing use of endovascular procedures. It is characterized by geometric shapes of nonscarring alopecia related to the area of radiation. We report a case of a 46-year-old man presenting with asymptomatic, sharply demarcated rectangular, nonscarring alopecic patch on the occipital scalp following cerebral angiography with fistula embolization under fluoroscopy. His presentations were compatible with radiation-induced alopecia. Herein, we also report a novel scalp dermoscopic finding of blue-grey dots in a target pattern around yellow dots and follicles, which we detected in the lesion of radiation-induced alopecia.

  12. Temporary patching of damaged UF{sub 6} cylinders

    Energy Technology Data Exchange (ETDEWEB)

    Cardenas, A.L. [Martin Marietta Energy Systems, Inc., OH (United States)

    1991-12-31

    Patching techniques based on application of epoxy resins have been developed for temporarily repairing UF{sub 6} cylinders which have sustained relatively minor damage and must be safely emptied. The method is considerably faster and simpler than metallurgical weld repairs. Laboratory tests, detailed operational procedures, and case histories of experience at the Portsmouth Gaseous Diffusion Plant are described.

  13. Influence of old rectangular repair patches on the burst pressure of a gas pipeline

    International Nuclear Information System (INIS)

    Fazzini, Pablo Gabriel; Otegui, Jose Luis

    2006-01-01

    Seven full scale hydrostatic burst tests were carried out on pipes extracted from an API 5LX52 gas pipeline that contained rectangular and elliptical fillet welded patches and other repairs of different geometries. All breaks took place after widespread yielding. This analysis shows that the patches that generate greater risks are those that: (1) were attached to the pipeline at very low pressure (2) were placed to repair large defects (3) are rectangular, long in the direction of the pipe, and narrow (4) the quality of the weld is doubtful. Based on data reported by In Line Inspection (ILI), of the four conditions mentioned above, only the third can be assessed in order to quantify risks and to schedule replacements

  14. Thermal and molecular investigation of laser tissue welding

    Science.gov (United States)

    Small, Ward, IV

    Despite the growing number of successful animal and human trials, the exact mechanisms of laser tissue welding remain unknown. Furthermore, the effects of laser heating on tissue on the molecular scale are not fully understood. To address these issues, a multi-front attack on both extrinsic (solder/patch mediated) and intrinsic (laser only) tissue welding was launched using two-color infrared thermometry, computer modeling, weld strength assessment, biochemical assays, and vibrational spectroscopy. The coupling of experimentally measured surface temperatures with the predictive numerical simulations provided insight into the sub surface dynamics of the laser tissue welding process. Quantification of the acute strength of the welds following the welding procedure enabled comparison among trials during an experiment, with previous experiments, and with other studies in the literature. The acute weld integrity also provided an indication of the probability of long-term success. Molecular effects induced in the tissue by laser irradiation were investigated by measuring the concentrations of specific collagen covalent crosslinks and measuring the infrared absorption spectra before and after the laser exposure. This investigation yielded results pertaining to both the methods and mechanisms of laser tissue welding. The combination of two-color infrared thermometry to obtain accurate surface temperatures free from emissivity bias and computer modeling illustrated the importance of including evaporation in the simulations, which effectively serves as an inherent cooling mechanism during laser irradiation. Moreover, the hydration state predicted by the model was useful in assessing the role of electrostatic versus covalent bonding in the fusion. These tools also helped elicit differences between dye- enhanced liquid solders and solid-matrix patches in laser-assisted tissue welding, demonstrating the significance of repeatable energy delivery. Surprisingly, covalent bonds

  15. Thermal and molecular investigation of laser tissue welding

    Energy Technology Data Exchange (ETDEWEB)

    Small, W., IV

    1998-06-01

    Despite the growing number of successful animal and human trials, the exact mechanisms of laser tissue welding remain unknown. Furthermore, the effects of laser heating on tissue on the molecular scale are not fully understood. To address these issues, a multi-front attack oil both extrinsic (solder/patch mediated) and intrinsic (laser only) tissue welding was launched using two-color infrared thermometry, computer modeling, weld strength assessment, biochemical assays, and vibrational spectroscopy. The coupling of experimentally measured surface temperatures with the predictive numerical simulations provided insight into the sub-surface dynamics of the laser tissue welding process. Quantification of the acute strength of the welds following the welding procedure enabled comparison among trials during an experiment, with previous experiments, and with other studies in the literature. The acute weld integrity also provided an indication of tile probability of long-term success. Molecular effects induced In the tissue by laser irradiation were investigated by measuring tile concentrations of specific collagen covalent crosslinks and characterizing the Fourier-Transform infrared (FTIR) spectra before and after the laser exposure.

  16. [Endovascular surgery in the war].

    Science.gov (United States)

    Reva, V A; Samokhvalov, I M

    2015-01-01

    Rapid growth of medical technologies has led to implementation of endovascular methods of diagnosis and treatment into rapidly developing battlefield surgery. This work based on analysing all available current publications generalizes the data on using endovascular surgery in combat vascular injury. During the Korean war (1950-1953) American surgeons for the first time performed endovascular balloon occlusion of the aorta - the first intravascular intervention carried out in a zone of combat operations. Half a century thereafter, with the beginning of the war in Afghanistan (2001) and in Iraq (2003) surgeons of central hospitals of the USA Armed Forces began performing delayed endovascular operations to the wounded. The development of technologies, advent of mobile angiographs made it possible to later on implement high-tech endovascular interventions in a zone of combat operations. At first, more often they performed implantation of cava filters, somewhat afterward - angioembolization of damaged accessory vessels, stenting and endovascular repair of major arteries. The first in the theatre of war endovascular prosthetic repair of the thoracic aorta for severe closed injury was performed in 2008. Russian experience of using endovascular surgery in combat injuries is limited to diagnostic angiography and regional intraarterial perfusion. Despite the advent of stationary angiographs in large hospitals of the RF Ministry of Defence in the early 1990s, endovascular operations for combat vascular injury are casuistic. Foreign experience in active implementation of endovascular technologies to treatment of war-time injuries has substantiated feasibility of using intravascular interventions in tertiary care military hospitals. Carrying out basic training courses on endovascular surgery should become an organic part of preparing multimodality general battlefield surgeons rendering care on the theatre of combat operations.

  17. 46 CFR 59.10-20 - Patches in shells and tube sheets.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Patches in shells and tube sheets. 59.10-20 Section 59.10-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING REPAIRS TO... wasted portion with a new section. The ligaments between the tube holes may be joined by means of welding...

  18. Manejo endovascular de la aorta torácica Endovascular treatment of thoracic aorta

    Directory of Open Access Journals (Sweden)

    Juan G Barrera

    2006-10-01

    Full Text Available En comparación con el tratamiento convencional, la terapia endovascular en aneurisma de aorta torácica, presenta los mejores resultados, por lo que se convierte en el tratamiento de elección para la patología de aorta torácica descendente endovascular, por su baja morbimortalidad perioperatoria. El tratamiento quirúrgico por vía retroperitoneal y/o endovascular para aneurisma de aorta abdominal infrarrenal, resulta ser especialmente seguro en pacientes octogenarios o con alta morbilidad. Esta cohorte institucional presenta resultados perioperatorios y en el seguimiento, similares a los reportados en la literatura mundial.Compared with the conventional treatment, endovascular therapy in thoracic aortic aneurysm shows the best results, being the election treatment for the pathology of the descending thoracic aorta, due to its low peri-operative morbid-mortality. Surgical treatment by retro-peritoneal route and/or endovascular for infra-renal abdominal aortic aneurysm is especially safe in octogenarian patients or in those with a high mortality rate. This institutional cohort show peri-operative and follow-up results similar to those reported in the world literature.

  19. Laser welding of chitosan-GNRs films for the closure of a capsulorhexis

    Science.gov (United States)

    Rossi, Francesca; Matteini, Paolo; Ratto, Fulvio; Menabuoni, Luca; Lenzetti, Ivo; Pini, Roberto

    2011-03-01

    In this work we present the first attempt to close the anterior lens capsule bag by the use of chitosan patches, where Gold Nanorods (GNRs) are embedded. GNRs exhibit intense localized plasmon resonances at optical frequencies in the near infrared (NIR): upon excitation with a NIR laser, a strong photothermal effect is produced, which can be exploited to develop minimally invasive therapies. Here we use the chitosan-GNRs films as a novel NIR sensitive nanocomposite for the photothermal conversion of NIR laser light during surgical interventions of tissue welding. Chitosan is an attractive biomaterial due to its biodegradability, biocompatibility, antimicrobial and wound healing-promoting activity. Colloidal GNRs were embedded in chitosan based, highly stabilized, flexible and easy-to-handle films, which were stored in water until the time of surgery. In these preliminary tests, a capsulorhexis was performed in freshly enucleated porcine eyes. The lens was aspired, then the patch was put onto the capsule bag and welded: a diode laser (810 nm) was used to deliver single spots (200 μm core diameter optical fiber) of local capsule/patch adhesion. Then the bag was refilled with silicon oil. The result is an immediate closure of the capsular tissue, with high mechanical strength. The laser welded chitosan- GNRs films are an innovative and highly stable solution to be exploited for the treatment of capsular breaks and for the implementation of a lens refilling procedure.

  20. Preoperative Evaluation and Endovascular Procedure of Intraoperative Aneurysm Rupture During Thoracic Endovascular Aortic Repair

    Energy Technology Data Exchange (ETDEWEB)

    Zha, Bin-Shan, E-mail: binszha2013@163.com; Zhu, Hua-Gang, E-mail: huagzhu@yeah.net; Ye, Yu-Sheng, E-mail: yeyusheng@aliyun.com; Li, Yong-Sheng, E-mail: 872868848@qq.com; Zhang, Zhi-Gong, E-mail: zzgedward@sina.com; Xie, Wen-Tao, E-mail: 345344347@qq.com [The First Affiliated Hospital of Anhui Medical University, Department of Vascular Surgery (China)

    2017-03-15

    Thoracic aortic aneurysms are now routinely repaired with endovascular repair if anatomically feasible because of advantages in safety and recovery. However, intraoperative aneurysm rupture is a severe complication which may have an adverse effect on the outcome of treatment. Comprehensive preoperative assessment and considerate treatment are keys to success of endovascular aneurysm repair, especially during unexpected circumstances. Few cases have reported on intraoperative aortic rupture, which were successfully managed by endovascular treatment. Here, we present a rare case of an intraoperative aneurysm rupture during endovascular repair of thoracic aortic aneurysm with narrow neck and angulated aorta arch (coarctation-associated aneurysm), which was successfully treated using double access route approach and iliac limbs of infrarenal devices.Level of EvidenceLevel 5.

  1. Endovascular Treatment of Late Thoracic Aortic Aneurysms after Surgical Repair of Congenital Aortic Coarctation in Childhood

    Science.gov (United States)

    Juszkat, Robert; Perek, Bartlomiej; Zabicki, Bartosz; Trojnarska, Olga; Jemielity, Marek; Staniszewski, Ryszard; Smoczyk, Wiesław; Pukacki, Fryderyk

    2013-01-01

    Background In some patients, local surgery-related complications are diagnosed many years after surgery for aortic coarctation. The purposes of this study were: (1) to systematically evaluate asymptomatic adults after Dacron patch repair in childhood, (2) to estimate the formation rate of secondary thoracic aortic aneurysms (TAAs) and (3) to assess outcomes after intravascular treatment for TAAs. Methods This study involved 37 asymptomatic patients (26 female and 11 male) who underwent surgical repair of aortic coarctation in the childhood. After they had reached adolescence, patients with secondary TAAs were referred to endovascular repair. Results Follow-up studies revealed TAA in seven cases (19%) (including six with the gothic type of the aortic arch) and mild recoarctation in other six (16%). Six of the TAA patients were treated with stentgrafts, but one refused to undergo an endovascular procedure. In three cases, stengrafts covered the left subclavian artery (LSA), in another the graft was implanted distally to the LSA. In two individuals, elective hybrid procedures were performed with surgical bypass to the supraaortic arteries followed by stengraft implantation. All subjects survived the secondary procedures. One patient developed type Ia endoleak after stentgraft implantation that was eventually treated with a debranching procedure. Conclusions The long-term course of clinically asymptomatic patients after coarctation patch repair is not uncommonly complicated by formation of TAAs (particularly in individuals with the gothic pattern of the aortic arch) that can be treated effectively with stentgrafts. However, in some patients hybrid procedures may be necessary. PMID:24386233

  2. High-power laser and arc welding of thorium-doped iridium alloys

    International Nuclear Information System (INIS)

    David, S.A.; Liu, C.T.

    1980-05-01

    The arc and laser weldabilities of two Ir-0.3% W alloys containing 60 and 200 wt ppM Th have been investigated. The Ir-.03% W alloy containing 200 wt ppM Th is severely prone to hot cracking during gas tungsten-arc welding. Weld metal cracking results from the combined effects of heat-affected zone liquation cracking and solidification cracking. Scanning electron microscopic analysis of the fractured surface revealed patches of low-melting eutectic. The cracking is influenced to a great extent by the fusion zone microstructure and thorium content. The alloy has been welded with a continuous-wave high-power CO 2 laser system with beam power ranging from 5 to 10 kW and welding speeds of 8 to 25 mm/s. Successful laser welds without hot cracking have been obtained in this particular alloy. This is attributable to the highly concentrated heat source available in the laser beam and the refinement in fusion zone microstructure obtained during laser welding. Efforts to refine the fusion zone structure during gas tungsten-arc welding of Ir-0.3 % W alloy containing 60 wt ppM Th were partially successful. Here transverse arc oscillation during gas tungsten-arc welding refines the fusion zone structure to a certain extent. However, microstructural analysis of this alloy's laser welds indicates further refinement in the fusion zone microstructure than in that from the gas tungsten-arc process using arc oscillations. The fusion zone structure of the laser weld is a strong function of welding speed

  3. Thoracic aortic aneurysms and dissections: endovascular treatment.

    Science.gov (United States)

    Baril, Donald T; Cho, Jae S; Chaer, Rabih A; Makaroun, Michel S

    2010-01-01

    The treatment of thoracic aortic disease has changed radically with the advances made in endovascular therapy since the concept of thoracic endovascular aortic repair was first described 15 years ago. Currently, there is a diverse array of endografts that are commercially available to treat the thoracic aorta. Multiple studies, including industry-sponsored and single-institution reports, have demonstrated excellent outcomes of thoracic endovascular aortic repair for the treatment of thoracic aortic aneurysms, with less reported perioperative morbidity and mortality in comparison with conventional open repair. Additionally, similar outcomes have been demonstrated for the treatment of type B dissections. However, the technology remains relatively novel, and larger studies with longer term outcomes are necessary to more fully evaluate the role of endovascular therapy for the treatment of thoracic aortic disease. This review examines the currently available thoracic endografts, preoperative planning for thoracic endovascular aortic repair, and outcomes of thoracic endovascular aortic repair for the treatment of both thoracic aortic aneurysms and type B aortic dissections. Mt Sinai J Med 77:256-269, 2010. (c) 2010 Mount Sinai School of Medicine.

  4. Development of maintenance technology with underwater TIG welding for spent fuel storage pool

    International Nuclear Information System (INIS)

    Obana, Takeshi; Hamada, Yasumitsu; Ooeda, Kaoru; Katou, Masahide; Ootsuka, Toshihiro; Toyoda, Seiichi; Hosogane, Atsushi

    2007-01-01

    The core technology of underwater TIG welding process has been developed and welding equipment system has been manufactured, for application to the maintenance of the spent fuel storage pool of Rokkasho reprocessing plant. Basic experiments for understanding the conditions of dry area and the range of welding conditions was performed, and mock examination for simulation of real environment by using the developed welding equipment was also carried out to judge the applicability of the system. For the purpose that can be selected water removing method for different spatial conditions of the parts to be maintained in underwater, two kinds of welding equipment systems of Chamber type and Partition type were developed and manufactured. On the basis of fundamental experiments, the conditions of dry area formation and welding parameters range for high-reliability weld were discussed. Thus the proper condition in this process was able to be established. With the welding equipment systems of the Chamber type and Partition type, the practical use examination of underwater TIG welding process was executed by mock examination for simulating the real environment. As a result, it was confirmed that the underwater TIG welding could obtain the same reliability as a usual in-air TIG welding, and the operation and the control at remote distance were also possible. And the reliability of the patch-plate fillet weld could be evaluated by remote inspection with the expansion visual test. (author)

  5. Endovascular treatment of PICA aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Mukonoweshuro, W.; Laitt, R.D.; Hughes, D.G. [Radiology Dept., Greater Manchester Neurosciences Unit, Hope Hospital, Salford, Manchester (United Kingdom)

    2003-03-01

    Endovascular treatment of aneurysms of the posterior inferior cerebellar artery (PICA) avoids manipulation of the brainstem or lower cranial nerves and should therefore carry a lower risk of neurological morbidity than surgical clipping. We reviewed our experience of 23 patients with PICA aneurysms treated by endovascular occlusion with Guglielmi detachable coils and documented their long-term outcome on follow-up. We observed a 28 day procedure-related neurological morbidity of 13% (3/23 patients). One patient suffered permanent neurological complications. There were no procedure-related deaths. None of our patients suffered a re-bleed from their treated aneurysms. Our series shows endovascular treatment of ruptured PICA aneurysms to be safe and effective. (orig.)

  6. ORIGINAL ARTICLES Endovascular treatment of cerebral ...

    African Journals Online (AJOL)

    With this in mind we looked at the costs ... of surgical or endovascular disposables. ... surgical versus endovascular treatment were 18 and 6 days .... 329: 527) gives a list of nine risk factors which explain most heart attacks: an abnormal ratio.

  7. Endovascular management of delayed post-pancreatectomy haemorrhage

    International Nuclear Information System (INIS)

    Pottier, Edwige; Ronot, Maxime; Vilgrain, Valerie; Gaujoux, Sebastien; Cesaretti, Manuela; Barbier, Louise; Sauvanet, Alain

    2016-01-01

    To assess the patient outcome after endovascular treatment of delayed post-pancreatectomy haemorrhage (PPH) as first-line treatment. Between January 2005 and November 2013, all consecutive patients referred for endovascular treatment of PPH were included. Active bleeding, pseudoaneurysms, collections and the involved artery were recorded on pretreatment CT. Endovascular procedures were classified as technical success (source of bleeding identified on angiogram and treated), technical failure (source of bleeding identified but incompletely treated) and abstention (no abnormality identified, no treatment performed). Factors associated with rebleeding were analysed. Sixty-nine patients (53 men) were included (mean 59 years old (32-75)). Pretreatment CT showed 27 (39 %) active bleeding. In 22 (32 %) cases, no involved artery was identified. Technical success, failure and abstention were observed in 48 (70 %), 9 (13 %) and 12 patients (17 %), respectively. Thirty patients (43 %) experienced rebleeding. Rebleeding rates were 29 %, 58 % and 100 % in case of success, abstention and failure (p < 0.001). Treatment failure/abstention was the only factor associated with rebleeding. Overall, 74 % of the patients were successfully treated by endovascular procedure(s) alone. After a first endovascular procedure for PPH, the rebleeding rate is high and depends upon the success of the procedure. Most patients are successfully treated by endovascular approach(es) alone. (orig.)

  8. Endovascular management of delayed post-pancreatectomy haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Pottier, Edwige [Beaujon Hospital, University Hospitals Paris Nord Val de Seine, Department of Radiology, Clichy, Hauts-de-Seine (France); Ronot, Maxime; Vilgrain, Valerie [Beaujon Hospital, University Hospitals Paris Nord Val de Seine, Department of Radiology, Clichy, Hauts-de-Seine (France); University Paris Diderot, Paris (France); INSERM U1149, centre de recherche biomedicale Bichat-Beaujon, CRB3, Paris (France); Gaujoux, Sebastien; Cesaretti, Manuela; Barbier, Louise [APHP, University Hospitals Paris Nord Val de Seine, Beaujon, Department of Surgery, Clichy, Hauts-de-Seine (France); Sauvanet, Alain [University Paris Diderot, Paris (France); APHP, University Hospitals Paris Nord Val de Seine, Beaujon, Department of Surgery, Clichy, Hauts-de-Seine (France)

    2016-10-15

    To assess the patient outcome after endovascular treatment of delayed post-pancreatectomy haemorrhage (PPH) as first-line treatment. Between January 2005 and November 2013, all consecutive patients referred for endovascular treatment of PPH were included. Active bleeding, pseudoaneurysms, collections and the involved artery were recorded on pretreatment CT. Endovascular procedures were classified as technical success (source of bleeding identified on angiogram and treated), technical failure (source of bleeding identified but incompletely treated) and abstention (no abnormality identified, no treatment performed). Factors associated with rebleeding were analysed. Sixty-nine patients (53 men) were included (mean 59 years old (32-75)). Pretreatment CT showed 27 (39 %) active bleeding. In 22 (32 %) cases, no involved artery was identified. Technical success, failure and abstention were observed in 48 (70 %), 9 (13 %) and 12 patients (17 %), respectively. Thirty patients (43 %) experienced rebleeding. Rebleeding rates were 29 %, 58 % and 100 % in case of success, abstention and failure (p < 0.001). Treatment failure/abstention was the only factor associated with rebleeding. Overall, 74 % of the patients were successfully treated by endovascular procedure(s) alone. After a first endovascular procedure for PPH, the rebleeding rate is high and depends upon the success of the procedure. Most patients are successfully treated by endovascular approach(es) alone. (orig.)

  9. Effects of electrocautery to provoke endovascular thermal injury Efeitos do eletrocautério para provocar lesão térmica endovascular

    Directory of Open Access Journals (Sweden)

    Fabio Henrique Rossi

    2011-10-01

    Full Text Available PURPOSE: To investigate the effects of a new electrocautery device to provoke endovascular venous thermal injury. METHODS: An experimental endovascular electrocautery was placed inside eight ex-vivo bovine saphenous veins models. Each one was divided in eight segments and progressive intensities of electric energy liberated. The macroscopic and microscopic effects were analyzed. RESULTS: Forty bovine saphenous veins segments were studied. The higher the electric energy applied the greater the nuclear picnosis and more intense the cytoplasmatic shrinkage and electrocoagulation effects. CONCLUSION: The experimental endovascular electrocautery device demonstrated to be both capable of inducing the destruction of the intimal layers of the studied vein model and provoke endovascular thermal injury.OBJETIVO: Investigar os efeitos de um modelo experimental de eletrocautério em provocar lesão venosa térmica endovascular. MÉTODOS: O eletrocautério endovascular foi colocado dentro de oito modelos experimentais de veia safena bovina. Cada uma foi dividida em oito segmentos e intensidades progressivas de energia elétrica liberada. Os efeitos macroscópicos e microscópicos foram analisados. RESULTADOS: Foram estudados quarenta segmentos de veia safena bovina. Quanto maior a energia elétrica aplicada pelo eletrocauterizador endovascular maiores foram as alteraçoes de picnose nuclear e mais intensa a retração citoplasmática observada. CONCLUSÃO: O eletrocautério endovascular experimental demonstrou ser capaz de induzir a destruição da camada íntima e provocar lesão térmica endovascular.

  10. Vascular training and endovascular practice in Europe

    DEFF Research Database (Denmark)

    Liapis, C.D.; Avgerinos, E.D.; Sillesen, H.

    2009-01-01

    specialties was distributed to a VS educator within 14 European countries. European Vascular and Endovascular Monitor (EVEM) data also were processed to correlate endovascular practice with training models. RESULTS: Fourteen questionnaires were gathered. Vascular training in Europe appears in 3 models: 1....... Mono-specialty (independence): 7 countries, 2. Subspecialty: 5 countries, 3. An existing specialty within general surgery: 2 countries. Independent compared to non-independent certification shortens overall training length (5.9 vs 7.9 years, p=0.006), while increasing overall training devoted......% respectively. Countries with independent vascular certification, despite their lower average endovascular index (procedures per 100,000 population), reported a higher growth rate of aortic endovascular procedures (VS independent 132% vs VS non-independent 87%), within a four-year period (2003-2007). Peripheral...

  11. Complications in Endovascular Neurosurgery: Critical Analysis and Classification.

    Science.gov (United States)

    Ravindra, Vijay M; Mazur, Marcus D; Park, Min S; Kilburg, Craig; Moran, Christopher J; Hardman, Rulon L; Couldwell, William T; Taussky, Philipp

    2016-11-01

    Precisely defining complications, which are used to measure overall quality, is necessary for critical review of delivery of care and quality improvement in endovascular neurosurgery, which lacks common definitions for complications. Furthermore, in endovascular interventions, events that may be labeled complications may not always negatively affect outcome. Our objective is to provide precise definitions for quality evaluation within endovascular neurosurgery. Thus, we propose an endovascular-specific classification system of complications based on our own patient series. This single-center review included all patients who had endovascular interventions from September 2013 to August 2015. Complication types were analyzed, and a descriptive analysis was undertaken to calculate the incidence of complications overall and in each category. Two hundred and seventy-five endovascular interventions were performed in 245 patients (65% female; mean age, 55 years). Forty complications occurred in 39 patients (15%), most commonly during treatment of intracranial aneurysms (24/40). Mechanical complications (eg, device deployment, catheter, or closure device failure) occurred in 8/40, technical complications (eg, failure to deploy flow diverter, unintended embolization, air emboli, retroperitoneal hemorrhage, dissection) in 11/40, judgment errors (eg, patient or equipment selection) in 9/40, and critical events (eg, groin hematoma, hemorrhagic or thromboembolic complications) in 12/40 patients. Only 12/40 complications (30%) resulted in new neurologic deficits, vessel injury requiring surgery, or blood transfusion. We propose an endovascular-specific classification system of complications with 4 categories: mechanical, technical, judgment errors, and critical events. This system provides a framework for future studies and quality control in endovascular neurosurgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Endovascular treatment of ruptured splenic artery aneurysm

    DEFF Research Database (Denmark)

    Bjerring, Ole Steen

    2008-01-01

    Splenic artery aneurysms (SAA) are traditionally treated surgically, but endovascular techniques are becoming increasingly popular. A 64 year-old male with chest pain and low blood pressure was admitted under suspicion of AMI. A CT scan showed a 56 mm SAA with signs of rupture. The patient...... was treated with endovascular embolisation of the SAA with coils. Blood pressure and haemoglobin levels were stabilized and the patient was discharged. In the case of rupture the treatment of choice seems to be endovascular....

  13. Endovascular Management of Acute Bleeding Arterioenteric Fistulas

    International Nuclear Information System (INIS)

    Leonhardt, Henrik; Mellander, Stefan; Snygg, Johan; Loenn, Lars

    2008-01-01

    The objective of this study was to review the outcome of endovascular transcatheter repair of emergent arterioenteric fistulas. Cases of abdominal arterioenteric fistulas (defined as a fistula between a major artery and the small intestine or colon, thus not the esophagus or stomach), diagnosed over the 3-year period between December 2002 and December 2005 at our institution, were retrospectively reviewed. Five patients with severe enteric bleeding underwent angiography and endovascular repair. Four presented primary arterioenteric fistulas, and one presented a secondary aortoenteric fistula. All had massive persistent bleeding with hypotension despite volume substitution and transfusion by the time of endovascular management. Outcome after treatment of these patients was investigated for major procedure-related complications, recurrence, reintervention, morbidity, and mortality. Mean follow-up time was 3 months (range, 1-6 months). All massive bleeding was controlled by occlusive balloon catheters. Four fistulas were successfully sealed with stent-grafts, resulting in a technical success rate of 80%. One patient was circulatory stabilized by endovascular management but needed immediate further open surgery. There were no procedure-related major complications. Mean hospital stay after the initial endovascular intervention was 19 days. Rebleeding occurred in four patients (80%) after a free interval of 2 weeks or longer. During the follow-up period three patients needed reintervention. The in-hospital mortality was 20% and the 30-day mortality was 40%. The midterm outcome was poor, due to comorbidities or rebleeding, with a mortality of 80% within 6 months. In conclusion, endovascular repair is an efficient and safe method to stabilize patients with life-threatening bleeding arterioenteric fistulas in the emergent episode. However, in this group of patients with severe comorbidities, the risk of rebleeding is high and further intervention must be considered

  14. Endovascular treatment of intracranial arteriovenous malformations

    International Nuclear Information System (INIS)

    Seruga, T.

    2002-01-01

    Background. The aim of the study was the introduction of endovascular interventional treatment of cerebral arteriovenous malformations (AVM) with superselective embolization with cyanoacrylic polymerisation agent. Case reports. Endovascular embolization was performed in five patients with cerebral AVMs. Three of these patients were presented with intracerebral haemathomas whereas in other two patients, cerebral AVM was an incidental finding. Superselective catheterisation of AVMs was performed and acrylic glue was selectively injected into the nidus. Conclusions. Control cerebral angiography after embolization of AVM showed different results. In one patient, AVM was totally occluded after three sessions and in second case AVM was occluded in a single session. The rate of occlusion in other two cases was estimated between 70% in 80%. Both of these two patients underwent surgery. One patient is still in the process of treatment. Endovascular treatment of cerebral AVMs with superselective embolization with liquid cyanoacrilyc adhesive agent is a safe and effective alternative treatment paths next to microsurgery. Endovascular treatment in combination with radiosurgery could become the method of choice in the therapy of cerebral AVMs in the future. (author)

  15. Endovascular treatment of spine and spinal cord lesions

    International Nuclear Information System (INIS)

    Berenstein, A.

    1992-01-01

    Completing this comprehensive series on endovascular interventional angiography, Volume 5 focuses on the vascular abnormalities of the spine and spinal cord. It is based on the detailed functional vascular anatomy described in Volume 3 and the principles and function of endovascular treatment described in Volumes 1-4. As in the companion volumes, the unique approach gives view of the disease itself, its anatomical features and its clinical presentation. The technical aspects of the interventional or endovascular neuroradiology are built upon the solid analysis of the disease and its angioarchitecture. The recent developments in endovascular procedures, such as aneurysm treatment, angioplasty, and vascular recanalizations, are reviewed. (orig.). 118 figs. in 442 separate illustrations

  16. Aneurisma de la aorta abdominal: Tratamiento endovascular con una endoprótesis fenestrada Abdominal aortic aneurysm: Endovascular treatment with fenestrated endoprothesis

    Directory of Open Access Journals (Sweden)

    Román Rostagno

    2008-12-01

    Full Text Available El tratamiento endovascular de los aneurismas de aorta abdominal es una alternativa a la cirugía abierta para pacientes de alto riesgo. Consiste en la exclusión del saco aneurismático mediante la interposición de una endoprótesis colocada por vía femoral. El tratamiento endovascular no puede ser utilizado en todos los pacientes. Una limitación frecuente la constituye el nacimiento de una arteria visceral desde el saco aneurismático. Para contrarrestar esta limitación recientemente se han desarrollado endoprótesis fenestradas que presentan orificios que se corresponden con el nacimiento de las arterias involucradas en el aneurisma evitando su oclusión, permitiendo de esta manera el tratamiento endovascular. En esta comunicación se presenta un caso de tratamiento endovascular de un aneurisma de aorta abdominal mediante la colocación de una endoprótesis fenestrada en un paciente cuya arteria renal izquierda nacía directamente del saco aneurismático.Endovascular treatment of the abdominal aortic aneurysm is consider an alternative to open surgery for high risk patients. Its goal is to exclude the aneurysm from the circulation by using an endoprothesis introduced from a femoral approach. Patients must be strictly selected to avoid possible complications. The most frequent limitation is related to anatomic contraindications such as visceral arteries involved in the aneurysm. Fenestrated endograft have been recently developed to allow endovascular treatment when anatomic features contraindicate classic endovascular procedures. Fenestrated endograft have holes that match with the origin of the visceral arteries maintaining its potency. In this paper we report the endovascular treatment of an abdominal aortic aneurysm by using a fenestrated endoprothesis in a patient whose left renal artery is originated from the aneurysm.

  17. Tratamento endovascular de lesões arteriais traumáticas Endovascular management of traumatic arterial injuries

    Directory of Open Access Journals (Sweden)

    Ruy Fernandes e Fernandes

    2011-03-01

    Full Text Available Introdução: As lesões arteriais traumáticas ocorrem em menos de 10% de politraumatizados e, nos países desenvolvidos, tem-se observado uma preponderância crescente de traumatismos vasculares iatrogénicos. Recentemente vários autores têm descrito a utilização de técnicas endovasculares com sucesso, pelo menor risco cirúrgico, em lesões de difícil acesso cujo tratamento convencional requer grande exposição cirúrgica, dificuldade técnica e mortalidade ou morbilidade apreciáveis. Os procedimentos endovasculares representam ainda uma alternativa terapêutica com menor mortalidade no tratamento de complicações crónicas de traumatismos vasculares, nomeadamente nos aneurismas pós-traumáticos do istmo aórtico (APTIA. Os autores apresentam uma série de doentes com lesões traumáticas arteriais diversas, em fase aguda ou crónica, tratados por via endovascular. Casos Clínicos: Sete doentes (21-77 anos, foram submetidos a tratamento endovascular de traumatismos vasculares na fase aguda ou crónica. Quatro doentes apresentavam lesões traumáticas agudas: 1 caso de rotura traumática do istmo aórtico (RTIA em politraumatismo por acidente de viação; 1 caso de rotura da artéria subclávia (RAS iatrogénica após tentativa de colocação de catéter de hemodiálise; 1 caso rotura de artéria renal (RAR durante angioplastia/stent por doença renovascular; 1 caso de fístula arterio-venosa (FAV da artéria renal intra-parenquimatosa iatrogénica após tumorectomia laparoscópica. Três doentes com complicações crónicas de traumatismos torácicos apresentavam falsos aneurismas do arco aórtico. Os doentes com roturas arteriais foram submetidos a exclusão endovascular com endoprótese e o doente com FAV renal foi submetido a embolização com coils. Os três doentes portadores de APTIA foram submetidos a: tratamento endovascular de aneurisma da aorta torácica (TEVAR-1; “debranching” com bypass carótido-subclávio e TEVAR-2

  18. Flow and wall shear stress characterization following endovascular aneurysm repair and endovascular aneurysm sealing in an infrarenal aneurysm model

    NARCIS (Netherlands)

    Boersen, Johannes T.; Groot Jebbink, Erik; Versluis, Michel; Slump, Cornelis H.; Ku, David N.; de Vries, Jean-Paul P.M.; Reijnen, Michel M.P.J.

    2017-01-01

    Background Endovascular aneurysm repair (EVAR) with a modular endograft has become the preferred treatment for abdominal aortic aneurysms. A novel concept is endovascular aneurysm sealing (EVAS), consisting of dual endoframes surrounded by polymer-filled endobags. This dual-lumen configuration is

  19. Endovascular repair of blunt popliteal arterial injuries

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Shan; Zhang, Xiquan; Chen, Zhong; Zhu, Wei; Pan, Xiaolin [Dept. of nterventional Vascular, The 148th Hospital of Chinese People' s Liberation Army, Zibo (China); Dong, Peng; Sun, Yequan [Dept. of Medical Imaging, Weifang Medical University, Weifang (China); Qi, Deming [Dept. of Medical Imaging, Qilu Medical University, Zibo (China)

    2016-09-15

    To evaluate the feasibility and effectiveness of endovascular repair for blunt popliteal arterial injuries. A retrospective analysis of seven patients with clinical suspicion of popliteal arterial injuries that were confirmed by arteriography was performed from September 2009 to July 2014. Clinical data included demographics, mechanism of injury, type of injury, location of injury, concomitant injuries, time of endovascular procedures, time interval from trauma to blood flow restoration, instrument utilized, and follow-up. All patients were male (mean age of 35.9 ± 10.3 years). The type of lesion involved intimal injury (n = 1), partial transection (n = 2), complete transection (n = 2), arteriovenous fistula (n = 1), and pseudoaneurysm (n = 1). All patients underwent endovascular repair of blunt popliteal arterial injuries. Technical success rate was 100%. Intimal injury was treated with a bare-metal stent. Pseudoaneurysm and popliteal artery transections were treated with bare-metal stents. Arteriovenous fistula was treated with bare-metal stent and coils. No perioperative death and procedure-related complication occurred. The average follow-up was 20.9 ± 2.3 months (range 18–24 months). One patient underwent intra-arterial thrombolysis due to stent thrombosis at 18 months after the procedure. All limbs were salvaged. Stent migration, deformation, or fracture was not found during the follow-up. Endovascular repair seems to be a viable approach for patients with blunt popliteal arterial injuries, especially on an emergency basis. Endovascular repair may be effective in the short-term. Further studies are required to evaluate the long-term efficacy of endovascular repair.

  20. Soldadura (Welding). Spanish Translations for Welding.

    Science.gov (United States)

    Hohhertz, Durwin

    Thirty transparency masters with Spanish subtitles for key words are provided for a welding/general mechanical repair course. The transparency masters are on such topics as oxyacetylene welding; oxyacetylene welding equipment; welding safety; different types of welds; braze welding; cutting torches; cutting with a torch; protective equipment; arc…

  1. Construct canine intracranial aneurysm model by endovascular technique

    International Nuclear Information System (INIS)

    Liang Xiaodong; Liu Yizhi; Ni Caifang; Ding Yi

    2004-01-01

    Objective: To construct canine bifurcation aneurysms suitable for evaluating the exploration of endovascular devices for interventional therapy by endovascular technique. Methods: The right common carotid artery of six dogs was expanded with a pliable balloon by means of endovascular technique, then embolization with detached balloon was taken at their originations DAS examination were performed on 1, 2, 3 d after the procedurse. Results: 6 aneurysm models were created in six dogs successfully with the mean width and height of the aneurysms decreasing in 3 days. Conclusions: This canine aneurysm model presents the virtue in the size and shape of human cerebral bifurcation saccular aneurysms on DSA image, suitable for developing the exploration of endovascular devices for aneurismal therapy. The procedure is quick, reliable and reproducible. (authors)

  2. Endovascular Management of Acute Limb Ischemia.

    LENUS (Irish Health Repository)

    Hynes, Brian G

    2011-09-14

    Despite major advances in pharmacologic and endovascular therapies, acute limb ischemia (ALI) continues to result in significant morbidity and mortality. The incidence of ALI may be as high as 13-17 cases per 100,000 people per year, with mortality rates approaching 18% in some series. This review will address the contemporary endovascular management of ALI encompassing pharmacologic and percutaneous interventional treatment strategies.

  3. Endovascular treatment of head and neck arteriovenous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Dmytriw, A.A. [University Health Network, Joint Department of Medical Imaging, Toronto, Ontario (Canada); Ter Brugge, K.G.; Krings, T.; Agid, R. [Toronto Western Hospital, Division of Neuroradiology, Department of Medical Imaging, Toronto, Ontario (Canada)

    2014-03-15

    Head and neck arteriovenous malformations (H and N AVM) are associated with considerable clinical and psychosocial burden and present a significant treatment challenge. We evaluated the presentation, response to treatment, and outcome of patients with H and N AVMs treated by endovascular means at our institution. Patients with H and N AVMs treated by endovascular means from 1984 to 2012 were evaluated retrospectively. These included AVMs involving the scalp, orbit, maxillofacial, and upper neck localizations. Patient's clinical files, radiological images, catheter angiograms, and surgical reports were reviewed. Eighty-nine patients with H and N AVMs (46 females, 43 males; 48 small, 41 large) received endovascular therapy. The goals of treatment were curative (n = 30), palliative (n = 34), or presurgical (n = 25). The total number of endovascular treatment sessions was 244 (average of 1.5 per patient). The goal of treatment was met in 92.1 % of cases. Eventual cure was achieved in 42 patients accounting for 58.4 % (52/89) of all patients who underwent treatment for any goal. Twenty-eight of these patients were cured by embolization alone (28/89, 31.4 %) of which 18 were single-hole AVFs. Twenty-four were cured by planned surgical excision after presurgical embolization (24/89, 27 %). Seven patients (7/89, 7.2 %) suffered transient and two (2/89, 2.2 %) permanent endovascular treatment complications. Endovascular treatment is effective for H and N AVMs and relatively safe. It is particularly effective for symptom palliation and presurgical aid. Embolization is curative mostly in small lesions and single-hole fistulas. In patients with large non-curable H and N AVMs, endovascular therapy is often the only palliative option. (orig.)

  4. Virtual reality simulation for the optimization of endovascular procedures: current perspectives

    Directory of Open Access Journals (Sweden)

    Rudarakanchana N

    2015-03-01

    Full Text Available Nung Rudarakanchana,1 Isabelle Van Herzeele,2 Liesbeth Desender,2 Nicholas JW Cheshire1 1Department of Surgery, Imperial College London, London, UK; 2Department of Thoracic and Vascular Surgery, Ghent University Hospital, Ghent, BelgiumOn behalf of EVEREST (European Virtual reality Endovascular RESearch TeamAbstract: Endovascular technologies are rapidly evolving, often requiring coordination and cooperation between clinicians and technicians from diverse specialties. These multidisciplinary interactions lead to challenges that are reflected in the high rate of errors occurring during endovascular procedures. Endovascular virtual reality (VR simulation has evolved from simple benchtop devices to full physic simulators with advanced haptics and dynamic imaging and physiological controls. The latest developments in this field include the use of fully immersive simulated hybrid angiosuites to train whole endovascular teams in crisis resource management and novel technologies that enable practitioners to build VR simulations based on patient-specific anatomy. As our understanding of the skills, both technical and nontechnical, required for optimal endovascular performance improves, the requisite tools for objective assessment of these skills are being developed and will further enable the use of VR simulation in the training and assessment of endovascular interventionalists and their entire teams. Simulation training that allows deliberate practice without danger to patients may be key to bridging the gap between new endovascular technology and improved patient outcomes.Keywords: virtual reality, simulation, endovascular, aneurysm

  5. Endovascular Intervention for Acute Ischemic Stroke in Light of Recent Trials

    Directory of Open Access Journals (Sweden)

    Kenan Alkhalili

    2014-01-01

    Full Text Available Three recently published trials, MR RESCUE, IMS III, and SYNTHESIS Expansion, evaluating the efficacy and safety of endovascular treatment of acute ischemic stroke have generated concerns about the future of endovascular approach. However, the tremendous evolution that imaging and endovascular treatment modalities have undergone over the past several years has raised doubts about the validity of these trials. In this paper, we review the role of endovascular treatment strategies in acute ischemic stroke and discuss the limitations and shortcomings that prevent generalization of the findings of recent trials. We also provide our experience in endovascular treatment of acute ischemic stroke.

  6. A look into the endovascular crystal ball

    DEFF Research Database (Denmark)

    Schroeder, Torben Veith

    2009-01-01

    This paper summarizes the highlights of the 15th International Workshop of Endovascular Surgery, held in Ajaccio in June 2008. This is an annual event that attracts leading endovascular therapists from both sides of the Atlantic Ocean as well as a contingency from down-under. The layout of this m...

  7. Endovascular treatment of complex traumatic lesions of the infrapopliteal segment Tratamento endovascular de lesões traumáticas complexas do segmento infrapoplíteo

    Directory of Open Access Journals (Sweden)

    Roberta C. A. Campos

    2009-06-01

    Full Text Available The occurrence of vascular trauma due to a range of causes has increased considerably. In this setting, endovascular repair has arisen as a new and less invasive approach. We report the case of three patients with lesions of below-knee vessels that were treated by endovascular procedures.A ocorrência de trauma vascular decorrente de diversas causas aumentou consideravelmente. Nesse contexto, o tratamento endovascular surge como um método novo e menos invasivo. Relatamos o caso de três pacientes com lesões abaixo do joelho que foram tratadas por procedimentos endovasculares.

  8. Virtual reality simulation for the optimization of endovascular procedures: current perspectives.

    Science.gov (United States)

    Rudarakanchana, Nung; Van Herzeele, Isabelle; Desender, Liesbeth; Cheshire, Nicholas J W

    2015-01-01

    Endovascular technologies are rapidly evolving, often requiring coordination and cooperation between clinicians and technicians from diverse specialties. These multidisciplinary interactions lead to challenges that are reflected in the high rate of errors occurring during endovascular procedures. Endovascular virtual reality (VR) simulation has evolved from simple benchtop devices to full physic simulators with advanced haptics and dynamic imaging and physiological controls. The latest developments in this field include the use of fully immersive simulated hybrid angiosuites to train whole endovascular teams in crisis resource management and novel technologies that enable practitioners to build VR simulations based on patient-specific anatomy. As our understanding of the skills, both technical and nontechnical, required for optimal endovascular performance improves, the requisite tools for objective assessment of these skills are being developed and will further enable the use of VR simulation in the training and assessment of endovascular interventionalists and their entire teams. Simulation training that allows deliberate practice without danger to patients may be key to bridging the gap between new endovascular technology and improved patient outcomes.

  9. Endovascular treatment of carotid-cavernous vascular lesions

    Directory of Open Access Journals (Sweden)

    GUILHERME BRASILEIRO DE AGUIAR

    Full Text Available ABSTRACT Objective: to evaluate the endovascular treatment of vascular lesions of the cavernous segment of the internal carotidartery (ICA performed at our institution. Methods: we conducted a descriptive, retrospective and prospective study of patients with aneurysms of the cavernous portion of the ICA or with direct carotid-cavernous fistulas (dCCF undergoing endovascular treatment. Results: we included 26 patients with intracavernous aneurysms and ten with dCCF. All aneurysms were treated with ICA occlusion. Those with dCCF were treated with occlusion in seven cases and with selective fistula occlusion in the remaining three. There was improvement of pain and ocular proptosis in all patients with dCCF. In patients with intracavernous aneurysms, the incidence of retro-orbital pain fell from 84.6% to 30.8% after treatment. The endovascular treatment decreased the dysfunction of affected cranial nerves in both groups, especially the oculomotor one. Conclusion: the endovascular treatment significantly improved the symptoms in the patients studied, especially those related to pain and oculomotor nerve dysfunction.

  10. CFRP-Strengthening and Long-Term Performance of Fatigue Critical Welds of a Steel Box Girder

    Directory of Open Access Journals (Sweden)

    Roland E. Koller

    2014-02-01

    Full Text Available Empa’s research efforts in the 1990s provided evidence that a considerable increase of the fatigue strength of welded aluminum beams can be achieved by externally bonding pultruded carbon fiber reinforced polymer (CFRP laminates using rubber-toughened epoxies over the fatigue-weak welding zone on their tensile flange. The reinforcing effect obtained is determined by the stiffness of the unidirectional CFRP laminate which has twice the elastic modulus of aluminum. One can therefore easily follow that an unstressed CFRP laminate reinforcement of welded beams made of steel will not lead to a substantial increase in fatigue strength of the steel structure. This consideration led to the idea of prestressing an external reinforcement of the welded zone. The present investigation describes experimental studies to identify the adhesive system suitable for achieving high creep and fatigue strength of the prestressed CFRP patch. Experimental results (Wöhler-fields of shear-lap-specimens and welded steel beams reinforced with prestressed CFRP laminates are presented. The paper concludes by presenting a field application, the reinforcement of a steel pendulum by adhesively bonded prestressed CFRP laminates to the tensile flanges of the welded box girder. Inspections carried out periodically on this structure revealed neither prestress losses nor crack initiation after nine years of service.

  11. Endovascular interventional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bartels, L W; Bakker, C J G

    2003-01-01

    Minimally invasive interventional radiological procedures, such as balloon angioplasty, stent placement or coiling of aneurysms, play an increasingly important role in the treatment of patients suffering from vascular disease. The non-destructive nature of magnetic resonance imaging (MRI), its ability to combine the acquisition of high quality anatomical images and functional information, such as blood flow velocities, perfusion and diffusion, together with its inherent three dimensionality and tomographic imaging capacities, have been advocated as advantages of using the MRI technique for guidance of endovascular radiological interventions. Within this light, endovascular interventional MRI has emerged as an interesting and promising new branch of interventional radiology. In this review article, the authors will give an overview of the most important issues related to this field. In this context, we will focus on the prerequisites for endovascular interventional MRI to come to maturity. In particular, the various approaches for device tracking that were proposed will be discussed and categorized. Furthermore, dedicated MRI systems, safety and compatibility issues and promising applications that could become clinical practice in the future will be discussed. (topical review)

  12. Tratamento endovascular de ruptura traumática da aorta torácica descendente Endovascular treatment of traumatic descending thoracic aortic rupture

    Directory of Open Access Journals (Sweden)

    João Roberto Breda

    2007-06-01

    Full Text Available Paciente do sexo feminino, 55 anos de idade, vítima de atropelamento, foi admitida em unidade de emergência, onde se realizou o diagnóstico clínico, radiológico e tomográfico de ruptura traumática da aorta torácica descendente. Diante do achado, a paciente foi encaminhada para tratamento endovascular com colocação de endoprótese auto-expansível (stent pela artéria femoral. O tratamento obteve sucesso, evidenciado pela exclusão da lesão localizada previamente no istmo aórtico. O tratamento endovascular tem sido indicado nas afecções de aorta torácica descendente com bons resultados iniciais. Na ruptura traumática de aorta, a terapêutica endovascular representa uma alternativa aceitável, especialmente devido aos riscos do tratamento operatório convencional.A 55-year-old, female patient who was run over by a motor vehicle was admitted at an emergency room. Clinical, radiological and tomographic diagnosis of traumatic descending aortic thoracic rupture was performed. The patient was referred for endovascular treatment with placement of a self-expandable stent through the femoral artery. Treatment was successful, with exclusion of the lesion previously located in the aortic isthmus. Endovascular treatment has been indicated in the treatment of descending thoracic aortic diseases, with good initial results. In case of traumatic aortic rupture, endovascular treatment is a feasible alternative, especially due to risks offered by the conventional surgical treatment.

  13. Simulation and augmented reality in endovascular neurosurgery: lessons from aviation.

    Science.gov (United States)

    Mitha, Alim P; Almekhlafi, Mohammed A; Janjua, Major Jameel J; Albuquerque, Felipe C; McDougall, Cameron G

    2013-01-01

    Endovascular neurosurgery is a discipline strongly dependent on imaging. Therefore, technology that improves how much useful information we can garner from a single image has the potential to dramatically assist decision making during endovascular procedures. Furthermore, education in an image-enhanced environment, especially with the incorporation of simulation, can improve the safety of the procedures and give interventionalists and trainees the opportunity to study or perform simulated procedures before the intervention, much like what is practiced in the field of aviation. Here, we examine the use of simulators in the training of fighter pilots and discuss how similar benefits can compensate for current deficiencies in endovascular training. We describe the types of simulation used for endovascular procedures, including virtual reality, and discuss the relevant data on its utility in training. Finally, the benefit of augmented reality during endovascular procedures is discussed, along with future computerized image enhancement techniques.

  14. The management of unimplantable stent during endovascular procedure:report of three cases

    International Nuclear Information System (INIS)

    Xiong Jiang; Wang Lijun; Guo Wei; Liu Xiaoping; Yin Tai; Jia Xin; Ma Xiaohui; Liu Meng; Zhang Hongpeng; Zhang Minhong

    2010-01-01

    Objective: To summarize the experience of dealing with the difficulty of the stent implantation encountered in the endovascular procedure. Methods: The causes of unimplantable stent encountered in the endovascular procedure included the delivery system entraping due to the stenosis and shrinking of peripheral self-expandable stent, the balloon expandable stent implantation and retrievement failure due to the rupture-balloon or stent edge opening, and the delivery system entraping due to aortic stent graft for aorta kinking. The balloon dilation for the stenosis and shrinking stent, the large caliber introducer sheath for removal of the rupture-balloon and edge opening, the expandable stent and balloon-assisted delivery system retrieve were used to solve the above three dilemma of unimplantable stent occurred in the endovascular procedure. Results: These three dilemma of stent unimplantable problem in the endovascular therapy were solved by endovascular method while little additional incision injury was added to the patients. Conclusion: For solving stent unimplantable problem the endovascular technique is the method of first choice, nevertherless, it is very important for the operator to be highly skilled in manipulating endovascular procedure. (authors)

  15. Image quality assessment based on inter-patch and intra-patch similarity.

    Directory of Open Access Journals (Sweden)

    Fei Zhou

    Full Text Available In this paper, we propose a full-reference (FR image quality assessment (IQA scheme, which evaluates image fidelity from two aspects: the inter-patch similarity and the intra-patch similarity. The scheme is performed in a patch-wise fashion so that a quality map can be obtained. On one hand, we investigate the disparity between one image patch and its adjacent ones. This disparity is visually described by an inter-patch feature, where the hybrid effect of luminance masking and contrast masking is taken into account. The inter-patch similarity is further measured by modifying the normalized correlation coefficient (NCC. On the other hand, we also attach importance to the impact of image contents within one patch on the IQA problem. For the intra-patch feature, we consider image curvature as an important complement of image gradient. According to local image contents, the intra-patch similarity is measured by adaptively comparing image curvature and gradient. Besides, a nonlinear integration of the inter-patch and intra-patch similarity is presented to obtain an overall score of image quality. The experiments conducted on six publicly available image databases show that our scheme achieves better performance in comparison with several state-of-the-art schemes.

  16. Endovascular treatment in pregnancy

    International Nuclear Information System (INIS)

    Ishii, Akira; Miyamoto, Susumu

    2013-01-01

    There is an increased risk of stroke during pregnancy and the puerperium. Decisions should be made immediately upon transfer to each institution, particularly with respect to when and how to treat the patient. This review highlights the feasibility of endovascular treatment in pregnancy. Most of the pharmaceutical agents and therapeutic devices used in clinical practice can be utilized in pregnant patients. Comprehensive information on the benefits and risks of treatment should be explained to the patient and her family, with particular attention to the safety of the mother and fetus. Radiation exposure to the fetus is also a concern; the hazard can be minimized with optimal protection. Several studies have demonstrated that conventional procedures do not cause serious radiation exposure exceeding the threshold of safety to the fetus. Endovascular therapy can be safely performed for the treatment of acute stroke as in non-pregnant patients with adequate attention to pharmaceutical agents and shielding from radiation. In contrast to therapy for acute stroke, preventive endovascular treatment for asymptomatic lesions remains controversial. Several conditions, such as cerebral aneurysms and arteriovenous malformations, are known to bleed more frequently in pregnancy, but whether the benefits of preventive treatment outweigh the associated risks is unknown. The decision for preventive treatment should be carefully made on a case-by-case basis after extensive discussion with the patient. (author)

  17. Endovascular management of acute bleeding arterioenteric fistulas

    DEFF Research Database (Denmark)

    Leonhardt, H.; Mellander, S.; Snygg, J.

    2008-01-01

    follow-up time was 3 months (range, 1-6 months). All massive bleeding was controlled by occlusive balloon catheters. Four fistulas were successfully sealed with stent-grafts, resulting in a technical success rate of 80%. One patient was circulatory stabilized by endovascular management but needed....... All had massive persistent bleeding with hypotension despite volume substitution and transfusion by the time of endovascular management. Outcome after treatment of these patients was investigated for major procedure-related complications, recurrence, reintervention, morbidity, and mortality. Mean...... arterioenteric fistulas in the emergent episode. However, in this group of patients with severe comorbidities, the risk of rebleeding is high and further intervention must be considered. Patients with cancer may only need treatment for the acute bleeding episode, and an endovascular approach has the advantage...

  18. Endovascular treatment of a true posterior communicating artery aneurysm.

    Science.gov (United States)

    Munarriz, Pablo M; Castaño-Leon, Ana M; Cepeda, Santiago; Campollo, Jorge; Alén, Jose F; Lagares, Alfonso

    2014-01-01

    Posterior communicating artery (PCoA) aneurysms are most commonly located at the junction of the internal carotid artery and the PCoA. "True" PCoA aneurysms, which originate from the PCoA itself, are rarely encountered. Most previously reported cases were treated surgically mainly before the endovascular option became available. A 53-year-old male presented with sudden onset of right hemiparesis and aphasia. Left middle cerebral artery stroke was diagnosed. Further studies revealed a 3 mm left PCoA aneurysm arising from the PCoA itself, attached to neither the internal carotid artery nor the posterior cerebral artery. Endovascular treatment was performed and the aneurysm was coiled completely. Technical advances in endovascular interventional technology have permitted an additional approach to these lesions. The possible endovascular significance of the treatment of true PCoA aneurysms is discussed.

  19. Prediction of Weld Residual Stress of Narrow Gap Welds

    International Nuclear Information System (INIS)

    Yang, Jun Seog; Huh, Nam Su

    2010-01-01

    The conventional welding technique such as shield metal arc welding has been mostly applied to the piping system of the nuclear power plants. It is well known that this welding technique causes the overheating and welding defects due to the large groove angle of weld. On the other hand, the narrow gap welding(NGW) technique has many merits, for instance, the reduction of welding time, the shrinkage of weld and the small deformation of the weld due to the small groove angle and welding bead width comparing with the conventional welds. These characteristics of NGW affect the deformation behavior and the distribution of welding residual stress of NGW, thus it is believed that the residual stress results obtained from conventional welding procedure may not be applied to structural integrity evaluation of NGW. In this paper, the welding residual stress of NGW was predicted using the nonlinear finite element analysis to simulate the thermal and mechanical effects of the NGW. The present results can be used as the important information to perform the flaw evaluation and to improve the weld procedure of NGW

  20. Clinical applications of robotic technology in vascular and endovascular surgery.

    Science.gov (United States)

    Antoniou, George A; Riga, Celia V; Mayer, Erik K; Cheshire, Nicholas J W; Bicknell, Colin D

    2011-02-01

    Emerging robotic technologies are increasingly being used by surgical disciplines to facilitate and improve performance of minimally invasive surgery. Robot-assisted intervention has recently been introduced into the field of vascular surgery to potentially enhance laparoscopic vascular and endovascular capabilities. The objective of this study was to review the current status of clinical robotic applications in vascular surgery. A systematic literature search was performed in order to identify all published clinical studies related to robotic implementation in vascular intervention. Web-based search engines were searched using the keywords "surgical robotics," "robotic surgery," "robotics," "computer assisted surgery," and "vascular surgery" or "endovascular" for articles published between January 1990 and November 2009. An evaluation and critical overview of these studies is reported. In addition, an analysis and discussion of supporting evidence for robotic computer-enhanced telemanipulation systems in relation to their applications in laparoscopic vascular and endovascular surgery was undertaken. Seventeen articles reporting on clinical applications of robotics in laparoscopic vascular and endovascular surgery were detected. They were either case reports or retrospective patient series and prospective studies reporting laparoscopic vascular and endovascular treatments for patients using robotic technology. Minimal comparative clinical evidence to evaluate the advantages of robot-assisted vascular procedures was identified. Robot-assisted laparoscopic aortic procedures have been reported by several studies with satisfactory results. Furthermore, the use of robotic technology as a sole modality for abdominal aortic aneurysm repair and expansion of its applications to splenic and renal artery aneurysm reconstruction have been described. Robotically steerable endovascular catheter systems have potential advantages over conventional catheterization systems

  1. Endovascular treatment of thoracic aorta aneurysm and dissection

    International Nuclear Information System (INIS)

    Petrov, I.; Stankov, Z.; Stefanov, St.; Stoyanov, Hr.

    2015-01-01

    Full text: The aim is to give up to date information about modern endovascular treatment of aortic pathology Dissection and aneurysms of the aorta are life threatening condition requiring in most of the cases prompt surgical or endovascular treatment because of the poor natural evolution. Purpose: to assess the immediate and 1-year outcome of endovascular treatment in broad spectrum of acute and subacute aortic syndrome during the last 3 years (November 2012 - August 2015) in City Clinic (Sofia, Bulgaria). We performed endovascular treatment of 47 patients (43 men, 4 women) at average age 54 y. with dissection (24) and aneurysms (23) of the aortic arch and thoracic aorta (in 5 emergent treatment was performed for aortic rupture). All patients were treated with minimal surgical femoral approach. In 4 (9%) of them initial carotid to carotid bypass was performed in order to provide a sufficient landing zone for the endograft implantation.the last 9 patients (19%) were treated without general anesthesia with either deep sedation or epidural anesthesia. Results: In all patients successful endograft implantation was achieved. Additional stent-graft or open cell stent was implanted in 4 cases in order to centralize the flow in the compressed true lumen. In 5 cases additional vascular plug or large coil was delivered in the left subclavian arteryostium in order to interrupt retrograde aneurysm or false lumen filling. Complications: 30 days mortality-2.2%, neurologic disorders (4.4%). one year survival- 45 (90.5%). 3 and 6 mo control CT scan showed no migration of the graft in 100%, full false lumen isolation in 19 out of 24 dissections (80%) and aneurysm free of expansion in 20 out of 23 (86%), patent carotid bay-pass graft in 4 of 4 (100%). This one center study showed excellent immediate and 1 year clinical and device results from endovascular repair of potentially fatal disease. Endovascular treatment is a method of choice for broad spectrum of aortic pathology

  2. Investigation on mechanical properties of welded material under different types of welding filler (shielded metal arc welding)

    Science.gov (United States)

    Tahir, Abdullah Mohd; Lair, Noor Ajian Mohd; Wei, Foo Jun

    2018-05-01

    The Shielded Metal Arc Welding (SMAW) is (or the Stick welding) defined as a welding process, which melts and joins metals with an arc between a welding filler (electrode rod) and the workpieces. The main objective was to study the mechanical properties of welded metal under different types of welding fillers and current for SMAW. This project utilized the Design of Experiment (DOE) by adopting the Full Factorial Design. The independent variables were the types of welding filler and welding current, whereas the other welding parameters were fixed at the optimum value. The levels for types of welding filler were by the models of welding filler (E6013, E7016 and E7018) used and the levels for welding current were 80A and 90A. The responses were the mechanical properties of welded material, which include tensile strength and hardness. The experiment was analyzed using the two way ANOVA. The results prove that there are significant effects of welding filler types and current levels on the tensile strength and hardness of the welded metal. At the same time, the ANOVA results and interaction plot indicate that there are significant interactions between the welding filler types and the welding current on both the hardness and tensile strength of the welded metals, which has never been reported before. This project found that when the amount of heat input with increase, the mechanical properties such as tensile strength and hardness decrease. The optimum tensile strength for welded metal is produced by the welding filler E7016 and the optimum of hardness of welded metal is produced by the welding filler E7018 at welding current of 80A.

  3. Open surgery versus endovascular approach in treatment of extracranial carotid artery aneurysms.

    Science.gov (United States)

    Ni, Leng; Weng, Huiling; Pu, Zuo; Zheng, Yuehong; Liu, Bao; Ye, Wei; Zeng, Rong; Liu, Changwei

    2018-05-01

    The objective of this study was to investigate and to compare the early and long-term results of open surgery with endovascular intervention in the treatment of extracranial carotid artery aneurysms (ECCAs). A retrospective review of patients diagnosed with ECCAs who underwent open surgical or endovascular treatment from 1997 to 2017 was performed. Clinical characteristics, aneurysm profile, and treatment outcomes were recorded. Early results (open surgery; endovascular repair was performed on 16 patients (33.3%). The 30-day stroke or transient ischemic attack rate was not significantly different between the open group (6.3% [2/32]) and the endovascular group (0% [0/16]; P = .307). Cranial nerve injuries occurred in eight patients in the open group (25%) and in no patient in the endovascular group (0%; P = .029). Median length of stay was significantly longer in the open group than in the endovascular group (20 vs 14 days, respectively; P = .013). Median follow-up was 46 months (range, 0-20 years), and no aneurysm-related death occurred during this period. Overall survival rates at 5 years were 88.7% (standard error [SE], 0.08) in the open group and 91.7% (SE, 0.08) in the endovascular group (P = .319; log-rank, .992). For the same time interval, stroke-free survival rates were 85.2% (SE, 0.10) in the open group and 92.2% (SE, 0.07) in the endovascular group (P = .653; log-rank, .201). One patient (1/28 [3.6%]) in the open group and two patients (2/16 [12.5%]) in the endovascular group underwent endovascular reinterventions because of restenosis during the follow-up period. Reintervention-free survival rates were 90.9% in the open group (SE, 0.09) and 69.2% in the endovascular group (SE, 0.21; P = .082; log-rank, 3.016). In this single-institutional experience, both operative and endovascular interventions for ECCAs provided acceptable early and 5-year results. The endovascular approach had significantly less cranial nerve injury and shorter length of

  4. Emergency endovascular coiling of a ruptured giant splenic artery aneurysm

    DEFF Research Database (Denmark)

    Wernheden, Erika; Brenøe, Anne Sofie; Shahidi, Saeid

    2017-01-01

    Splenic artery aneurysms (SAAs) are the third most common abdominal aneurysm. Endovascular treatment of SAAs is preferred, and coiling is the most commonly used technique. Ruptured giant (>5 cm) SAAs are usually treated with open surgery including splenectomy. We present a rare case of a ruptured...... 15-cm giant SAA in an 84-year-old woman treated successfully with emergency endovascular coiling. To our knowledge, this is one of the few reports of emergency endovascular treatment for ruptured giant SAA....

  5. Early endovascular treatment of superior mesenteric occlusion secondary to thromboemboli.

    Science.gov (United States)

    Jia, Z; Jiang, G; Tian, F; Zhao, J; Li, S; Wang, K; Wang, Y; Jiang, L; Wang, W

    2014-02-01

    To evaluate our early experience with endovascular revascularization in patients with acute thromboembolic occlusion of the superior mesenteric artery (SMA). A retrospective review was conducted of all patients who underwent endovascular revascularization for acute thromboembolic SMA occlusion from May 2005 to May 2012. Endovascular revascularization was performed using aspiration, intra-arterial thrombolysis, and adjunctive stent-placement techniques. Laparotomy was performed if the patient developed clinical signs of advanced bowel ischemia after endovascular procedure. Twenty-one patients underwent endovascular revascularization for acute thromboembolic SMA occlusion. All presented with acute-onset abdominal pain. Three patients had rebound tenderness before the procedure. Computed tomography angiography revealed complete occlusion in seven cases and incomplete occlusion in 14 cases, with no evidence of free gas or bowel necrosis. The median duration from onset of symptoms to revascularization was 8.7 ± 4.1 hours (range, 2-18 hours). Completely successful endovascular revascularization occurred in six cases (aspiration alone, 3 cases; combined aspiration and urokinase, 3 cases); partial success was achieved in 15 cases (aspiration alone, 4 cases; combined aspiration and urokinase, 10 cases; and combined aspiration, urokinase, and stent placement, 1 case). Laparotomy was required in five patients, all of whom had SMA main trunk complete occlusion and required small bowel resection. The 30-day mortality for all patients was 9.5%. During a median follow-up of 26 months, 15 patients remained asymptomatic, three patients reported occasional abdominal pain, and one patient had temporary short-bowel syndrome. Percutaneous revascularization is a promising alternative to surgery for acute SMA occlusion in selected patients who have no signs of advanced bowel ischemia. Early diagnosis followed by prompt endovascular intervention with close postprocedural monitoring is

  6. Endovascular Treatment Strategies in Aortoiliac Occlusion

    International Nuclear Information System (INIS)

    Ozkan, Ugur; Oguzkurt, Levent; Tercan, Fahri; Gumus, Burcak

    2009-01-01

    The aim of this study was to report our experience in endovascular treatment of total aortoiliac occlusion. Five patients who underwent endovascular recanalization procedures including manual aspiration thrombectomy, balloon angioplasty, and stent placement for total aortoiliac occlusion in a 4-year period were reviewed retrospectively. The mean age of patients was 51 years (range, 43 to 58 years). All patients had abdominal aorta and bilateral common iliac artery occlusion with or without external iliac artery occlusion. All patients either had a contraindication to surgery or refused it. Initial technical success was obtained in four of five (80%) patients. Endovascular techniques were successful in four patients who had good distal runoff and short-segment aortoiliac occlusion, but failed in a patient who had the worst distal runoff and long-segment aortoiliac occlusion. We observed two major complications, one of which was bilateral rupture of the common iliac arteries treated with covered stent placement. Another patient had extension of intra-aortic thrombus into the iliac stent after primary stenting. This was successfully treated with manual aspiration thrombectomy. Aortic and iliac stents remained patent during the follow-up period (median, 18 months; range, 3 to 26 months) in four patients. Primary patency rates at 6, 12, and 24 months were all 80%. In conclusion, endovascular treatment can be an alternative for aortoiliac occlusion in selected patients. Short- to midterm follow-up so far is satisfactory. Removal of intra-aortic thrombus with manual aspiration thrombectomy before balloon angioplasty and/or stenting is possible and a good alternative to thrombolysis.

  7. Endovascular treatment of cerebral aneurysms - a cost analysis | Le ...

    African Journals Online (AJOL)

    The average cost for endovascular treatment per patient was R37 041. Surgical treatment was more expensive at R44 104, a difference of 16%. Conclusions. Despite the high cost of endovascular devices, appropriate use of this technology ultimately offers less expensive treatment than microsurgical clipping of aneurysms.

  8. Emergency endovascular coiling of a ruptured giant splenic artery aneurysm

    Directory of Open Access Journals (Sweden)

    Erika Wernheden, MD

    2017-12-01

    Full Text Available Splenic artery aneurysms (SAAs are the third most common abdominal aneurysm. Endovascular treatment of SAAs is preferred, and coiling is the most commonly used technique. Ruptured giant (>5 cm SAAs are usually treated with open surgery including splenectomy. We present a rare case of a ruptured 15-cm giant SAA in an 84-year-old woman treated successfully with emergency endovascular coiling. To our knowledge, this is one of the few reports of emergency endovascular treatment for ruptured giant SAA.

  9. Standards for Endovascular Neurosurgical Training and Certification of the Society of Korean Endovascular Neurosurgeons 2013

    Science.gov (United States)

    Shin, Dong-Seong; Park, Sukh-Que; Kang, Hyun-Seung; Yoon, Seok-Mann; Cho, Jae-Hoon; Lim, Dong-Jun; Baik, Min-Woo; Kwon, O Ki

    2014-01-01

    The need for standard endovascular neurosurgical (ENS) training programs and certification in Korea cannot be overlooked due to the increasing number of ENS specialists and the expanding ENS field. The Society of Korean Endovascular Neurosurgeons (SKEN) Certification Committee has prepared training programs and certification since 2010, and the first certificates were issued in 2013. A task force team (TFT) was organized in August 2010 to develop training programs and certification. TFT members researched programs and systems in other countries to develop a program that best suited Korea. After 2 years, a rough draft of the ENS training and certification regulations were prepared, and the standard training program title was decided. The SKEN Certification Committee made an official announcement about the certification program in March 2013. The final certification regulations comprised three major parts: certified endovascular neurosurgeons (EN), certified ENS institutions, and certified ENS training institutions. Applications have been evaluated and the results were announced in June 2013 as follows: 126 members received EN certification and 55 hospitals became ENS-certified institutions. The SKEN has established standard ENS training programs together with a certification system, and it is expected that they will advance the field of ENS to enhance public health and safety in Korea. PMID:24851145

  10. Weld Nugget Temperature Control in Thermal Stir Welding

    Science.gov (United States)

    Ding, R. Jeffrey (Inventor)

    2014-01-01

    A control system for a thermal stir welding system is provided. The control system includes a sensor and a controller. The sensor is coupled to the welding system's containment plate assembly and generates signals indicative of temperature of a region adjacent and parallel to the welding system's stir rod. The controller is coupled to the sensor and generates at least one control signal using the sensor signals indicative of temperature. The controller is also coupled to the welding system such that at least one of rotational speed of the stir rod, heat supplied by the welding system's induction heater, and feed speed of the welding system's weld material feeder are controlled based on the control signal(s).

  11. Transition welds in welding of two-ply steels

    International Nuclear Information System (INIS)

    Fartushnyj, V.G.; Evsyukov, Yu.G.

    1977-01-01

    Studied were physico-mechanical properties of welds made by various welding wires of chromium-nickel and nickel-chromium steels in submerged arc welding of double-layer steels with main layer of the VSt.3sp. carbon steel. It is shown that service-reliable structures welded of two-layer steels are obtained by providing the content from 11 to 20 % Ni in the automatically welded transition layer

  12. Coevolution of patch-type dependent emigration and patch-type dependent immigration.

    Science.gov (United States)

    Weigang, Helene C

    2017-08-07

    The three phases of dispersal - emigration, transfer and immigration - are affecting each other and the former and latter decisions may depend on patch types. Despite the inevitable fact of the complexity of the dispersal process, patch-type dependencies of dispersal decisions modelled as emigration and immigration are usually missing in theoretical dispersal models. Here, I investigate the coevolution of patch-type dependent emigration and patch-type dependent immigration in an extended Hamilton-May model. The dispersing population inhabits a landscape structured into many patches of two types and disperses during a continuous-time season. The trait under consideration is a four dimensional vector consisting of two values for emigration probability from the patches and two values for immigration probability into the patches of each type. Using the adaptive dynamics approach I show that four qualitatively different dispersal strategies may evolve in different parameter regions, including a counterintuitive strategy, where patches of one type are fully dispersed from (emigration probability is one) but individuals nevertheless always immigrate into them during the dispersal season (immigration probability is one). I present examples of evolutionary branching in a wide parameter range, when the patches with high local death rate during the dispersal season guarantee a high expected disperser output. I find that two dispersal strategies can coexist after evolutionary branching: a strategy with full immigration only into the patches with high expected disperser output coexists with a strategy that immigrates into any patch. Stochastic simulations agree with the numerical predictions. Since evolutionary branching is also found when immigration evolves alone, the present study is adding coevolutionary constraints on the emigration traits and hence finds that the coevolution of a higher dimensional trait sometimes hinders evolutionary diversification. Copyright © 2017

  13. Weld controller for automated nuclear service welding

    International Nuclear Information System (INIS)

    Barfield, K.L.; Strubhar, P.M.; Green, D.I.

    1995-01-01

    B and W Nuclear Technologies (BWNT) uses many different types of weld heads for automated welding in the commercial nuclear service industry. Some weld heads are purchased as standard items, while others are custom designed and fabricated by BWNT requiring synchronized multiaxis motion control. BWNT recently completed a development program to build a common weld controller that interfaces to all types of weld heads used by BWNT. Their goal was to construct a system that had the flexibility to add different modules to increase the capability of the controller as different application needs become necessary. The benefits from having a common controller are listed. This presentation explains the weld controller system and the types of applications to which it has been applied

  14. Perioperative complications in endovascular neurosurgery: Anesthesiologist's perspective

    Science.gov (United States)

    Sharma, Megha U.; Ganjoo, Pragati; Singh, Daljit; Tandon, Monica S.; Agarwal, Jyotsna; Sharma, Durga P.; Jagetia, Anita

    2017-01-01

    Background: Endovascular neurosurgery is known to be associated with potentially serious perioperative complications that can impact the course and outcome of anesthesia. We present here our institutional experience in the anesthetic management of various endovascular neurosurgical procedures and their related complications over a 10-year period. Methods: Data was obtained in 240 patients pertaining to their preoperative status, details of anesthesia and surgery, perioperative course and surgery-related complications. Information regarding hemodynamic alterations, temperature variability, fluid-electrolyte imbalance, coagulation abnormalities and alterations in the anesthesia course was specifically noted. Results: Among the important complications observed were aneurysm rupture (2.5%), vasospasm (6.67%), thromboembolism (4.16%), contrast reactions, hemodynamic alterations, electrolyte abnormalities, hypothermia, delayed emergence from anesthesia, groin hematomas and early postoperative mortality (5.14%). Conclusion: Awareness of the unique challenges of endovascular neurosurgery and prompt and appropriate management of the associated complications by an experienced neuroanesthesiologist is vital to the outcome of these procedures. PMID:28413524

  15. Sleep Sleeping Patch

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The Sleep Sleeping Patch is a new kind of external patch based on modern sleep medicine research achievements, which uses the internationally advanced transdermal therapeutic system (TTS). The Sleep Sleeping Patch transmits natural sleep inducers such as peppermint and liquorice extracts and melatonin through the skin to induce sleep. Clinical research proves that the Sleep Sleeping Patch can effectively improve insomnia and the quality of sleep. Highly effective: With the modern TTS therapy,

  16. Use of servo controlled weld head for end closure welding

    Energy Technology Data Exchange (ETDEWEB)

    Pathak, S.K.; Setty, D.S.; Rameswara Rao, A.; Hemantha Rao, G.V.S.; Jayaraj, R.N. [Nuclear Fuel Complex, Dept. of Atomic Energy, Hyderabad (India)

    2010-07-01

    In the PHWR fuel fabrication line resistance welding processes are used for joining various zirconium based alloy components to fuel tube of similar material. The quality requirement of these welding processes is very stringent and has to meet all the product requirements. At present these welding processes are being carried out by using standard resistance welding machines. In the resistance welding process in addition to current and time, force is one of the critical and important parameter, which influences the weld quality. At present advanced feed back type fast response medium frequency weld controllers are being used. This has upslope/down slope, constant and repetitive weld pattern selection features makes this critical welding process more reliable. Compared to weld controllers, squeeze force application devices are limited and normally standard high response pneumatic cylinders are used in the welding process. With this type of devices the force is constant during welding process and cannot be varied during welding process as per the material deformation characteristics. Similarly due to non-availability of feed back systems in the squeeze force application systems restricts the accuracy and quality of the welding process. In the present paper the influence of squeeze force pattern on the weld quality using advanced feed back type servo based force control system was studied. Different squeeze forces were used during pre and post weld heat periods along with constant force and compared with the weld quality. (author)

  17. Welding hazards

    International Nuclear Information System (INIS)

    Khan, M.A.

    1992-01-01

    Welding technology is advancing rapidly in the developed countries and has converted into a science. Welding involving the use of electricity include resistance welding. Welding shops are opened in residential area, which was causing safety hazards, particularly the teenagers and children who eagerly see the welding arc with their naked eyes. There are radiation hazards from ultra violet rays which irritate the skin, eye irritation. Welding arc light of such intensity could damage the eyes. (Orig./A.B.)

  18. Endovascular stents: a review of their use in peripheral arterial disease.

    Science.gov (United States)

    Kudagi, Vinod S; White, Christopher J

    2013-06-01

    Technological advances in the past decade have shifted revascularization strategies from traditional open surgical approaches toward lower-morbidity percutaneous endovascular treatments for patients with lower extremity peripheral arterial disease (PAD). The continuing advances in stent design, more than any other advances, have fueled the growth of catheter-based procedures by improving the safety, durability, and predictability of percutaneous revascularization. Although the 2007 TransAtlantic Inter-Society Consensus (TASC) guidelines recommend endovascular therapy for type A and B aortoiliac and femoropopliteal lesions, recent developments in stent technology and increased experience of interventionists have suggested that a strategy of endovascular therapy first is appropriate in experienced hands for TASC type D lesions. The role of endovascular interventions is also expanding in the treatment of limb-threatening ischemia.

  19. Modern radiosurgical and endovascular classification schemes for brain arteriovenous malformations.

    Science.gov (United States)

    Tayebi Meybodi, Ali; Lawton, Michael T

    2018-05-04

    Stereotactic radiosurgery (SRS) and endovascular techniques are commonly used for treating brain arteriovenous malformations (bAVMs). They are usually used as ancillary techniques to microsurgery but may also be used as solitary treatment options. Careful patient selection requires a clear estimate of the treatment efficacy and complication rates for the individual patient. As such, classification schemes are an essential part of patient selection paradigm for each treatment modality. While the Spetzler-Martin grading system and its subsequent modifications are commonly used for microsurgical outcome prediction for bAVMs, the same system(s) may not be easily applicable to SRS and endovascular therapy. Several radiosurgical- and endovascular-based grading scales have been proposed for bAVMs. However, a comprehensive review of these systems including a discussion on their relative advantages and disadvantages is missing. This paper is dedicated to modern classification schemes designed for SRS and endovascular techniques.

  20. Three-dimensional (3D) printed endovascular simulation models: a feasibility study.

    Science.gov (United States)

    Mafeld, Sebastian; Nesbitt, Craig; McCaslin, James; Bagnall, Alan; Davey, Philip; Bose, Pentop; Williams, Rob

    2017-02-01

    Three-dimensional (3D) printing is a manufacturing process in which an object is created by specialist printers designed to print in additive layers to create a 3D object. Whilst there are initial promising medical applications of 3D printing, a lack of evidence to support its use remains a barrier for larger scale adoption into clinical practice. Endovascular virtual reality (VR) simulation plays an important role in the safe training of future endovascular practitioners, but existing VR models have disadvantages including cost and accessibility which could be addressed with 3D printing. This study sought to evaluate the feasibility of 3D printing an anatomically accurate human aorta for the purposes of endovascular training. A 3D printed model was successfully designed and printed and used for endovascular simulation. The stages of development and practical applications are described. Feedback from 96 physicians who answered a series of questions using a 5 point Likert scale is presented. Initial data supports the value of 3D printed endovascular models although further educational validation is required.

  1. Advanced Welding Concepts

    Science.gov (United States)

    Ding, Robert J.

    2010-01-01

    Four advanced welding techniques and their use in NASA are briefly reviewed in this poster presentation. The welding techniques reviewed are: Solid State Welding, Friction Stir Welding (FSW), Thermal Stir Welding (TSW) and Ultrasonic Stir Welding.

  2. Resistance seam welding

    International Nuclear Information System (INIS)

    Schueler, A.W.

    1977-01-01

    The advantages and disadvantages of the resistance seam welding process are presented. Types of seam welds, types of seam welding machines, seam welding power supplies, resistance seam welding parameters and seam welding characteristics of various metals

  3. Endovascular repair of para-anastomotic aortoiliac aneurysms.

    LENUS (Irish Health Repository)

    Tsang, Julian S

    2009-11-01

    The purpose of this study is to evaluate the use of endovascular stent grafts in the treatment of para-anastomotic aneurysms (PAAs) as an alternative to high-risk open surgical repair. We identified all patients with previous open aortic aneurysm repair who underwent infrarenal endovascular aneurysm repair (EVAR) at our institution from June 1998 to April 2007. Patient demographics, previous surgery, and operative complications were recorded. One hundred forty-eight patients underwent EVAR during the study period and 11 patients had previous aortic surgery. Of these 11 redo patients, the mean age was 62 years at initial surgery and 71 years at EVAR. All patients were male. Initial open repair was for rupture in five (45%) patients. The average time between initial and subsequent reintervention was 9 years. All patients were ASA Grade III or IV. Fifty-five percent of the PAAs involved the iliac arteries, 36% the abdominal aorta, and 9% were aortoiliac. Ten patients had endovascular stent-grafts inserted electively, and one patient presented with a contained leak. Aorto-uni-iliac stent-grafts were deployed in seven patients, and bifurcated stent-grafts in four patients. A 100% successful deployment rate was achieved. Perioperative mortality was not seen and one patient needed surgical reintervention to correct an endoleak. Endovascular repair of PAAs is safe and feasible. It is a suitable alternative and has probably now become the treatment of choice in the management of PAAs.

  4. Welding method, and welding device for use therein, and method of analysis for evaluating welds

    NARCIS (Netherlands)

    Aendenroomer, A.J.; Den Ouden, G.; Xiao, Y.H.; Brabander, W.A.J.

    1995-01-01

    Described is a method of automatically welding pipes, comprising welding with a pulsation welding current and monitoring, by means of a sensor, the variations occurring in the arc voltage caused by weld pool oscillations. The occurrence of voltage variations with only frequency components below 100

  5. Comparison of Welding Residual Stresses of Hybrid Laser-Arc Welding and Submerged Arc Welding in Offshore Steel Structures

    DEFF Research Database (Denmark)

    Andreassen, Michael Joachim; Yu, Zhenzhen; Liu, Stephen

    2016-01-01

    In the offshore industry, welding-induced distortion and tensile residual stresses have become a major concern in relation to the structural integrity of a welded structure. Particularly, the continuous increase in size of welded plates and joints needs special attention concerning welding induced...... residual stresses. These stresses have a negative impact on the integrity of the welded joint as they promote distortion, reduce fatigue life, and contribute to corrosion cracking and premature failure in the weld components. This paper deals with the influence and impact of welding method on the welding...... induced residual stresses. It is also investigated whether the assumption of residual stresses up to yield strength magnitude are present in welded structures as stated in the design guidelines. The fatigue strength for welded joints is based on this assumption. The two welding methods investigated...

  6. Correção endovascular de persistência do conduto arterioso em paciente adulto Endovascular approach for persistent ductus arteriosus closure in adult patient

    Directory of Open Access Journals (Sweden)

    José Carlos Dorsa Vieira Pontes

    2010-03-01

    Full Text Available O tratamento da Persistência do Canal Arterial (PCA, em adultos, ainda é controverso. A utilização de próteses auto-expansíveis tem-se mostrado como uma alternativa eficaz ao tratamento cirúrgico. Apresentamos um caso de uma paciente de 45 anos submetida ao tratamento endovascular com o uso de stent auto-expansível.The treatment for closure of persistent ductus arteriosus (PDA in adults still controversial. The endovascular approach has been shown as an effective alternative to surgical treatment. We report a case of 45 years old pacient submitted to endovascular approach for PDA closure.

  7. Endovascular Neurosurgery: Personal Experience and Future Perspectives.

    Science.gov (United States)

    Raymond, Jean

    2016-09-01

    From Luessenhop's early clinical experience until the present day, experimental methods have been introduced to make progress in endovascular neurosurgery. A personal historical narrative, spanning the 1980s to 2010s, with a review of past opportunities, current problems, and future perspectives. Although the technology has significantly improved, our clinical culture remains a barrier to methodologically sound and safe innovative care and progress. We must learn how to safely practice endovascular neurosurgery in the presence of uncertainty and verify patient outcomes in real time. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Welding technology transfer task/laser based weld joint tracking system for compressor girth welds

    Science.gov (United States)

    Looney, Alan

    1991-01-01

    Sensors to control and monitor welding operations are currently being developed at Marshall Space Flight Center. The laser based weld bead profiler/torch rotation sensor was modified to provide a weld joint tracking system for compressor girth welds. The tracking system features a precision laser based vision sensor, automated two-axis machine motion, and an industrial PC controller. The system benefits are elimination of weld repairs caused by joint tracking errors which reduces manufacturing costs and increases production output, simplification of tooling, and free costly manufacturing floor space.

  9. Friction Stir Welding

    Science.gov (United States)

    Nunes, Arthur C., Jr.

    2008-01-01

    Friction stir welding (FSW) is a solid state welding process invented in 1991 at The Welding Institute in the United Kingdom. A weld is made in the FSW process by translating a rotating pin along a weld seam so as to stir the sides of the seam together. FSW avoids deleterious effects inherent in melting and promises to be an important welding process for any industries where welds of optimal quality are demanded. This article provides an introduction to the FSW process. The chief concern is the physical effect of the tool on the weld metal: how weld seam bonding takes place, what kind of weld structure is generated, potential problems, possible defects for example, and implications for process parameters and tool design. Weld properties are determined by structure, and the structure of friction stir welds is determined by the weld metal flow field in the vicinity of the weld tool. Metal flow in the vicinity of the weld tool is explained through a simple kinematic flow model that decomposes the flow field into three basic component flows: a uniform translation, a rotating solid cylinder, and a ring vortex encircling the tool. The flow components, superposed to construct the flow model, can be related to particular aspects of weld process parameters and tool design; they provide a bridge to an understanding of a complex-at-first-glance weld structure. Torques and forces are also discussed. Some simple mathematical models of structural aspects, torques, and forces are included.

  10. Numerical analysis of weld pool oscillation in laser welding

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jung Ho [Chungbuk National University, Cheongju (Korea, Republic of); Farson, Dave F [The Ohio State University, Columbus (United States); Hollis, Kendall; Milewski, John O. [Los Alamos National Laboratory, Los Alamos (United States)

    2015-04-15

    Volume of fluid (VOF) numerical simulation was used to investigate melt flow and volumetric oscillation of conduction-mode pulsed laser weld pools. The result is compared to high speed video stream of titanium laser spot welding experiment. The total simulation time is 10ms with the first 5 ms being heating and melting under constant laser irradiation and the remaining 5 ms corresponding to resolidification of the weld pool. During the melting process, the liquid pool did not exhibit periodic oscillation but was continually depressed by the evaporation recoil pressure. After the laser pulse, the weld pool was excited into volumetric oscillation by the release of pressure on its surface and oscillation of the weld pool surface was analyzed. The simulation model suggested adjusting thermal diffusivity to match cooling rate and puddle diameter during solidification which is distinguishable from previous weld pool simulation. The frequency continuously increased from several thousand cycles per second to tens of thousands of cycles per second as the weld pool solidified and its diameter decreased. The result is the first trial of investigation of small weld pool oscillation in laser welding although there have been several reports about arc welding.

  11. Endovascular Versus Open Surgical Intervention in Patients with Takayasu's Arteritis: A Meta-analysis.

    Science.gov (United States)

    Jung, Jae Hyun; Lee, Young Ho; Song, Gwan Gyu; Jeong, Han Saem; Kim, Jae-Hoon; Choi, Sung Jae

    2018-06-01

    Although medical treatment has advanced, surgical treatment is needed to control symptoms of Takayasu's arteritis (TA), such as angina, stroke, hypertension, or claudication. Endovascular or open surgical intervention is performed; however, there are few comparative studies on these methods. This meta-analysis and systematic review aimed to examine the outcome of surgical treatment of TA. A meta-analysis comparing outcomes of endovascular and open surgical intervention was performed using MEDLINE and Embase. This meta-analysis included only observational studies, and the evidence level was low to moderate. Data were pooled and analysed using a fixed or random effects model with the I 2 statistic. The included studies involved a total of 770 patients and 1363 lesions, with 389 patients treated endovascularly and 420 treated by surgical revascularization. Restenosis was more common with endovascular than open surgical intervention (odds ratio [OR] 5.18, 95% confidence interval [CI] 2.78-9.62; p open surgical intervention patients in the coronary artery, supra-aortic branches, and renal artery. In both the active and inactive stages, restenosis was more common in those treated endovascularly than in those treated by open surgery. However, stroke occurred less often with endovascular intervention than with open surgical intervention (OR 0.33, 95% CI 0.12-0.90; p = .003). Mortality and complications other than stroke and mortality did not differ between endovascular and open surgical intervention. This meta-analysis has shown a lower risk of restenosis with open surgical intervention than with endovascular intervention. Stroke was generally more common with open surgical intervention than with endovascular intervention. However, there were differences according to the location of the lesion, and the risk of stroke in open surgery is higher when the supra-aortic branches are involved rather than the renal arteries. Copyright © 2018 European Society for Vascular

  12. Alternate Welding Processes for In-Service Welding

    Science.gov (United States)

    2009-04-24

    Conducting weld repairs and attaching hot tap tees onto pressurized pipes has the advantage of avoiding loss of service and revenue. However, the risks involved with in-service welding need to be managed by ensuring that welding is performed in a rep...

  13. Aortic Arch Aneurysms: Treatment with Extra anatomical Bypass and Endovascular Stent-Grafting

    International Nuclear Information System (INIS)

    Kato, Noriyuki; Shimono, Takatsugu; Hirano, Tadanori; Mizumoto, Toru; Ishida, Masaki; Fujii, Hideki; Yada, Isao; Takeda, Kan

    2002-01-01

    Endovascular repair of thoracic aortic aneurysms is emerging as an attractive alternative to surgical graft replacement. However,patients with aortic arch aneurysms are often excluded from the target of endovascular repair because of lack of suitable landing zones, especially at the proximal ones. In this paper we describe our method for treating patients with aortic arch aneurysms using a combination of extra anatomical bypass surgery and endovascular stent-grafting

  14. Hybrid laser-TIG welding, laser beam welding and gas tungsten arc welding of AZ31B magnesium alloy

    International Nuclear Information System (INIS)

    Liu Liming; Wang Jifeng; Song Gang

    2004-01-01

    Welding of AZ31B magnesium alloy was carried out using hybrid laser-TIG (LATIG) welding, laser beam welding (LBW) and gas tungsten arc (TIG) welding. The weldability and microstructure of magnesium AZ31B alloy welded using LATIG, LBW and TIG were investigated by OM and EMPA. The experimental results showed that the welding speed of LATIG was higher than that of TIG, which was caught up with LBW. Besides, the penetration of LATIG doubles that of TIG, and was four times that of LBW. In addition, arc stability was improved in hybrid of laser-TIG welding compared with using the TIG welding alone, especially at high welding speed and under low TIG current. It was found that the heat affect zone of joint was only observed in TIG welding, and the size of grains in it was evidently coarse. In fusion zone, the equiaxed grains exist, whose size was the smallest welded by LBW, and was the largest by TIG welding. It was also found that Mg concentration of the fusion zone was lower than that of the base one by EPMA in three welding processes

  15. Closing the weld gap with laser/mig hybrid welding process

    DEFF Research Database (Denmark)

    Bagger, Claus; Olsen, Flemming Ove; Wiwe, Bjarne David

    2003-01-01

    In this article, laboratory tests are demonstrated that systematically accesses the critical gap distance when welding CMn 2.13 mm steel with a 2.6 kW CO2 laser, combined with a MIG energy source. In the work, the welding speed is varied at gap distances from 0 to 0.8 mm such that the limits...... for obtaining sound welds are identified. The welds are quality assessed according to ISO 13.919-1 and EN25817, transversal hardness measurements are made and the heat input to the workpiece is calculated. The results show that the critical gap is 0.1 mm for a laser weld alone. With hybrid welding, this can...... be increased to 0.6 mm, even at a welding speed of 3.5 m/min. The maximum welding speed with the hybrid process is comparable to laser welding alone, 4.5 m/min. The measured hardness is comparable to MIG welding, and this corresponds to a 33 percent reduction compared to laser welding alone. The heat input...

  16. Utility of gadolinium as a contrast medium in endovascular therapeutic procedures; Utilidad del gadolinio como medio de contraste en procedimientos terapeuticos endovasculares

    Energy Technology Data Exchange (ETDEWEB)

    Reyes, R.; Pardo, M. D.; Gorriz, E.; Gallardo, L. (Hospital de Gran Canaria Dr. Negrin); Carreira, J. M. (Universidad de Santiago de Compostela)

    2001-07-01

    To assess the utility of gadolinium associated with CO{sub 2}, as a contrast medium in angiographic studies related to endovascular therapeutic procedures in patients with suboptimal renal function. Between January 2000 and June 2001, endovascular treatments using CO{sub 2} and gadolinium as contrast medium were performed in 10 patients presenting renal function deterioration (creatinine>1.5 mg/ml). A mean dose of 42 ml of gadolinium was administered. The images acquired in diagnostic and therapeutic studied were satisfactory in every case. There was no evidence of significant increases in the previous urea and creatine levels when measured 24, 48 and 72 hours after the procedure. In combination with CO{sub 2} gadolinium is a useful contrast medium for endovascular therapeutic procedures in patients with suboptimal renal function. (Author) 21 refs.

  17. Content Validation and Evaluation of an Endovascular Teamwork Assessment Tool.

    Science.gov (United States)

    Hull, L; Bicknell, C; Patel, K; Vyas, R; Van Herzeele, I; Sevdalis, N; Rudarakanchana, N

    2016-07-01

    To modify, content validate, and evaluate a teamwork assessment tool for use in endovascular surgery. A multistage, multimethod study was conducted. Stage 1 included expert review and modification of the existing Observational Teamwork Assessment for Surgery (OTAS) tool. Stage 2 included identification of additional exemplar behaviours contributing to effective teamwork and enhanced patient safety in endovascular surgery (using real-time observation, focus groups, and semistructured interviews of multidisciplinary teams). Stage 3 included content validation of exemplar behaviours using expert consensus according to established psychometric recommendations and evaluation of structure, content, feasibility, and usability of the Endovascular Observational Teamwork Assessment Tool (Endo-OTAS) by an expert multidisciplinary panel. Stage 4 included final team expert review of exemplars. OTAS core team behaviours were maintained (communication, coordination, cooperation, leadership team monitoring). Of the 114 OTAS behavioural exemplars, 19 were modified, four removed, and 39 additional endovascular-specific behaviours identified. Content validation of these 153 exemplar behaviours showed that 113/153 (73.9%) reached the predetermined Item-Content Validity Index rating for teamwork and/or patient safety. After expert team review, 140/153 (91.5%) exemplars were deemed to warrant inclusion in the tool. More than 90% of the expert panel agreed that Endo-OTAS is an appropriate teamwork assessment tool with observable behaviours. Some concerns were noted about the time required to conduct observations and provide performance feedback. Endo-OTAS is a novel teamwork assessment tool, with evidence for content validity and relevance to endovascular teams. Endo-OTAS enables systematic objective assessment of the quality of team performance during endovascular procedures. Copyright © 2016. Published by Elsevier Ltd.

  18. Endovascular therapy options in femoro-popliteal PAD; Endovaskulaere Therapieoptionen bei femoropoplitealer pAVK

    Energy Technology Data Exchange (ETDEWEB)

    Brechtel, Klaus [Universitaetsklinikum Tuebingen (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie

    2010-09-15

    The endovascular treatment of femoro-popliteal PAD is still challenging. The number of endovascular procedures in this vessel segment has increased over the past years. Despite new technologies, the outcome of endovascular therapy in terms of durability is still weak. In the meantime, the latest developments are progressing, such as the combination of mechanical angioplasty and drug delivery. Additionally, there are former techniques, such as debulking by atherectomy, which have been technically improved and now contribute to modern concepts of endovascular treatment. This article provides an overview on treatment indications and technical options including the latest technical developments. (orig.)

  19. LASER WELDING WITH MICRO-JET COOLING FOR TRUCK FRAME WELDING

    Directory of Open Access Journals (Sweden)

    Jan PIWNIK

    2017-12-01

    Full Text Available The aim of this paper is to analyse the mechanical properties of the weld steel structure of car body truck frames after laser welding. The best welding conditions involve the use of proper materials and alloy elements in steel and filer materials, in addition to welding technology, state of stress and temperature of exploitation. We present for the first time the properties of steel track structures after laser welding with micro-jet cooling. Therefore, good selection of both welding parameters and micro-jet cooling parameters is very important to achieve a proper steel structure. In this study, the metallographic structure, tensile results and impact toughness of welded joints have been analysed in terms of welding parameters.

  20. Forming Completely Penetrated Welded T-joints when Pulsed Arc Welding

    Science.gov (United States)

    Krampit, N. Yu; Krampit, M. A.; Sapozhkov, A. S.

    2016-04-01

    The paper is focused on revealing the influence of welding parameters on weld formation when pulsed arc welding. As an experimental sample a T-joint over 10 mm was selected. Welding was carried out in flat position, which required no edge preparation but provided mono-directional guaranteed root penetration. The following parameters of welding were subjected to investigation: gap in the joint, wire feed rate and incline angles of the torch along and across the weld axis. Technological recommendations have been made with respect to pulsed arc welding; the cost price of product manufacturing can be reduced on their basis due to reduction of labor input required by machining, lowering consumption of welding materials and electric power.

  1. Resistance welding

    DEFF Research Database (Denmark)

    Bay, Niels; Zhang, Wenqi; Rasmussen, Mogens H.

    2003-01-01

    Resistance welding comprises not only the well known spot welding process but also more complex projection welding operations, where excessive plastic deformation of the weld point may occur. This enables the production of complex geometries and material combinations, which are often not possible...... to weld by traditional spot welding operations. Such joining processes are, however, not simple to develop due to the large number of parameters involved. Development has traditionally been carried out by large experimental investigations, but the development of a numerical programme system has changed...... this enabling prediction of the welding performance in details. The paper describes the programme in short and gives examples on industrial applications. Finally investigations of causes for failure in a complex industrial joint of two dissimilar metals are carried out combining numerical modelling...

  2. Cu-Fe welding techniques by electromagnetic and electron beam welding processes

    International Nuclear Information System (INIS)

    Kumar, Satendra; Saroj, P.C.; Kulkarni, M.R.; Sharma, A.; Rajawat, R.K.; Saha, T.K.

    2015-01-01

    Electromagnetic welding being a solid state welding process has been found suitable for welding Copper and Iron which are conventionally very tricky. Owing to good electrical conductivity of both copper and iron, they are best suited combination for EM welding. For the experimental conditions presented above, 1.0 mm wall thickness of Cu tube was lap welded to Fe disc. A heavy duty four disc stainless steel coil was used for electromagnetic welding of samples. MSLD of the welded samples indicated leak proof joints. Metallographic examination of the welds also revealed defect free interfaces. Electron beam welding is also a non-conventional welding process used for joining dissimilar materials. Autogenous welding of the above specimen was carried out by EBW method for the sake of comparison. A characterization analysis of the above mentioned joining processes will be discussed in the paper. (author)

  3. Deconvoluting the Friction Stir Weld Process for Optimizing Welds

    Science.gov (United States)

    Schneider, Judy; Nunes, Arthur C.

    2008-01-01

    In the friction stir welding process, the rotating surfaces of the pin and shoulder contact the weld metal and force a rotational flow within the weld metal. Heat, generated by the metal deformation as well as frictional slippage with the contact surface, softens the metal and makes it easier to deform. As in any thermo-mechanical processing of metal, the flow conditions are critical to the quality of the weld. For example, extrusion of metal from under the shoulder of an excessively hot weld may relax local pressure and result in wormhole defects. The trace of the weld joint in the wake of the weld may vary geometrically depending upon the flow streamlines around the tool with some geometry more vulnerable to loss of strength from joint contamination than others. The material flow path around the tool cannot be seen in real time during the weld. By using analytical "tools" based upon the principles of mathematics and physics, a weld model can be created to compute features that can be observed. By comparing the computed observations with actual data, the weld model can be validated or adjusted to get better agreement. Inputs to the model to predict weld structures and properties include: hot working properties ofthe metal, pin tool geometry, travel rate, rotation and plunge force. Since metals record their prior hot working history, the hot working conditions imparted during FSW can be quantified by interpreting the final microstructure. Variations in texture and grain size result from variations in the strain accommodated at a given strain rate and temperature. Microstructural data from a variety of FSWs has been correlated with prior marker studies to contribute to our understanding of the FSW process. Once this stage is reached, the weld modeling process can save significant development costs by reducing costly trial-and-error approaches to obtaining quality welds.

  4. Effects of Fusion Tack Welds on Self-Reacting Friction Stir Welds

    Science.gov (United States)

    Nunes, A. C., Jr.; Pendleton, M. L.; Brooke, S. A.; Russell, C. K.

    2012-01-01

    In order to know whether fusion tack welds would affect the strength of self-reacting friction stir seam welds in 2195-T87 aluminum alloy, the fracture stresses of 144 tensile test coupons cut from 24 welded panels containing segments of friction stir welds were measured. Each of the panels was welded under unique processing conditions. A measure of the effect of the tack welds for each panel was devised. An analysis of the measures of the tack weld effect supported the hypothesis that fusion tack welds do not affect the strength of self-reacting friction stir welds to a 5% level of confidence.

  5. Residual stress reduction in the penetration nozzle weld joint by overlay welding

    International Nuclear Information System (INIS)

    Jiang, Wenchun; Luo, Yun; Wang, B.Y.; Tu, S.T.; Gong, J.M.

    2014-01-01

    Highlights: • Residual stress reduction in penetration weld nozzle by overlay welding was studied. • The overlay weld can decrease the residual stress in the weld root. • Long overlay welding is proposed in the actual welding. • Overlay weld to decrease residual stress is more suitable for thin nozzle. - Abstract: Stress corrosion cracking (SCC) in the penetration nozzle weld joint endangers the structural reliability of pressure vessels in nuclear and chemical industries. How to decrease the residual stress is very critical to ensure the structure integrity. In this paper, a new method, which uses overlay welding on the inner surface of nozzle, is proposed to decrease the residual stresses in the penetration joint. Finite element simulation is used to study the change of weld residual stresses before and after overlay welding. It reveals that this method can mainly decrease the residual stress in the weld root. Before overlay welding, large tensile residual stresses are generated in the weld root. After overlay weld, the tensile hoop stress in weld root has been decreased about 45%, and the radial stress has been decreased to compressive stress, which is helpful to decrease the susceptibility to SCC. With the increase of overlay welding length, the residual stress in weld root has been greatly decreased, and thus the long overlay welding is proposed in the actual welding. It also finds that this method is more suitable for thin nozzle rather than thick nozzle

  6. Fault-patch stress-transfer efficiency in presence of sub-patch geometric complexity

    KAUST Repository

    Zielke, Olaf

    2015-04-01

    It is well known that faults are not planar surfaces. Instead they exhibit self-similar or self-affine properties that span a wide range of spatial (sub-micrometer to tens-of-kilometer). This geometric fault roughness has a distinct impact on amount and distribution of stresses/strains induced in the medium and on other portions of the fault. However, when numerically simulated (for example in multi-cycle EQ rupture simulations or Coulomb failure stress calculations) this roughness is largely ignored: individual fault patches --the incremental elements that build the fault surface in the respective computer models-- are planar and fault roughness at this and lower spatial scales is not considered. As a result, the fault-patch stress-transfer efficiency may be systematically too large in those numerical simulations with respect to the "actual" efficiency level. Here, we investigate the effect of sub-patch geometric complexity on fault-patch stress-transfer efficiency. For that, we sub-divide a fault patch (e.g., 1x1km) into a large number of sub-patches (e.g., 20x20m) and determine amount of induced stresses at selected positions around that patch for different levels and realizations of fault roughness. For each fault roughness level, we compute mean and standard deviation of the induced stresses, enabling us to compute the coefficient of variation. We normalize those values with stresses from the corresponding single (planar) fault patch, providing scaling factors and their variability for stress transfer efficiency. Given a certain fault roughness that is assumed for a fault, this work provides the means to implement the sub-patch fault roughness into investigations based on fault-patch interaction schemes.

  7. Welding processes handbook

    CERN Document Server

    Weman, Klas

    2011-01-01

    Offers an introduction to the range of available welding technologies. This title includes chapters on individual techniques that cover principles, equipment, consumables and key quality issues. It includes material on such topics as the basics of electricity in welding, arc physics, and distortion, and the weldability of particular metals.$bThe first edition of Welding processes handbook established itself as a standard introduction and guide to the main welding technologies and their applications. This new edition has been substantially revised and extended to reflect the latest developments. After an initial introduction, the book first reviews gas welding before discussing the fundamentals of arc welding, including arc physics and power sources. It then discusses the range of arc welding techniques including TIG, plasma, MIG/MAG, MMA and submerged arc welding. Further chapters cover a range of other important welding technologies such as resistance and laser welding, as well as the use of welding techniqu...

  8. Endovascular and surgical treatment of spinal dural arteriovenous fistulas

    International Nuclear Information System (INIS)

    Andres, Robert H.; University of Berne; Stanford University Medical Center, Department of Neurosurgery, Stanford, CA; University of Berne; Barth, Alain; Medical University of Graz, Department of Neurosurgery, Graz; University of Berne; Guzman, Raphael; Stanford University Medical Center, Department of Neurosurgery, Stanford, CA; University of Berne; Remonda, Luca; El-Koussy, Marwan; Schroth, Gerhard; University of Berne; Seiler, Rolf W.; Widmer, Hans R.; University of Berne

    2008-01-01

    The aim of this retrospective study was to evaluate the clinical outcome of patients with spinal dural arteriovenous fistulas (SDAVFs) that were treated with surgery, catheter embolization, or surgery after incomplete embolization. The study included 21 consecutive patients with SDAVFs of the thoracic, lumbar, or sacral spine who were treated in our institution from 1994 to 2007. Thirteen patients were treated with catheter embolization alone. Four patients underwent hemilaminectomy and intradural interruption of the fistula. Four patients were treated by endovascular techniques followed by surgery. The clinical outcome was assessed using the modified Aminoff-Logue scale (ALS) for myelopathy and the modified Rankin scale (MRS) for general quality of life. Patient age ranged from 44 to 77 years (mean 64.7 years). Surgical as well as endovascular treatment resulted in a significant improvement in ALS (-62.5% and -31.4%, respectively, p<0.05) and a tendency toward improved MRS (-50% and -32%, respectively) scores. Patients that underwent surgery after endovascular treatment due to incomplete occlusion of the fistula showed only a tendency for improvement in the ALS score (-16.7%), whereas the MRS score was not affected. We conclude that both endovascular and surgical treatment of SDAVFs resulted in a good and lasting clinical outcome in the majority of cases. In specific situations, when a secondary neurosurgical approach was required after endovascular treatment to achieve complete occlusion of the SDAVF, the clinical outcome was rather poor. The best first line treatment modality for each individual patient should be determined by an interdisciplinary team. (orig.)

  9. Contemporary management of carotid blowout syndrome utilizing endovascular techniques.

    Science.gov (United States)

    Manzoor, Nauman F; Rezaee, Rod P; Ray, Abhishek; Wick, Cameron C; Blackham, Kristine; Stepnick, David; Lavertu, Pierre; Zender, Chad A

    2017-02-01

    To illustrate complex interdisciplinary decision making and the utility of modern endovascular techniques in the management of patients with carotid blowout syndrome (CBS). Retrospective chart review. Patients treated with endovascular strategies and/or surgical modalities were included. Control of hemorrhage, neurological, and survival outcomes were studied. Between 2004 and 2014, 33 patients had 38 hemorrhagic events related to head and neck cancer that were managed with endovascular means. Of these, 23 were localized to the external carotid artery (ECA) branches and five localized to the ECA main trunk; nine were related to the common carotid artery (CCA) or internal carotid artery (ICA), and one event was related to the innominate artery. Seven events related to the CCA/ICA or innominate artery were managed with endovascular sacrifice, whereas three cases were managed with a flow-preserving approach (covered stent). Only one patient developed permanent hemiparesis. In two of the three cases where the flow-preserving approach was used, the covered stent eventually became exposed via the overlying soft tissue defect, and definitive management using carotid revascularization or resection was employed to prevent further hemorrhage. In cases of soft tissue necrosis, vascularized tissues were used to cover the great vessels as applicable. The use of modern endovascular approaches for management of acute CBS yields optimal results and should be employed in a coordinated manner by the head and neck surgeon and the neurointerventionalist. 4. Laryngoscope, 2016 127:383-390, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  10. Welding Curriculum.

    Science.gov (United States)

    Alaska State Dept. of Education, Juneau. Div. of Adult and Vocational Education.

    This competency-based curriculum guide is a handbook for the development of welding trade programs. Based on a survey of Alaskan welding employers, it includes all competencies a student should acquire in such a welding program. The handbook stresses the importance of understanding the principles associated with the various elements of welding.…

  11. LASER WELDING WITH MICRO-JET COOLING FOR TRUCK FRAME WELDING

    OpenAIRE

    Jan PIWNIK; Bożena SZCZUCKA-LASOTA; Tomasz WĘGRZYN; Wojciech MAJEWSKI

    2017-01-01

    The aim of this paper is to analyse the mechanical properties of the weld steel structure of car body truck frames after laser welding. The best welding conditions involve the use of proper materials and alloy elements in steel and filer materials, in addition to welding technology, state of stress and temperature of exploitation. We present for the first time the properties of steel track structures after laser welding with micro-jet cooling. Therefore, good selection of both welding paramet...

  12. Thermal Stir Welding: A New Solid State Welding Process

    Science.gov (United States)

    Ding, R. Jeffrey

    2003-01-01

    Thermal stir welding is a new welding process developed at NASA's Marshall Space Flight Center in Huntsville, AL. Thermal stir welding is similar to friction stir welding in that it joins similar or dissimilar materials without melting the parent material. However, unlike friction stir welding, the heating, stirring and forging elements of the process are all independent of each other and are separately controlled. Furthermore, the heating element of the process can be either a solid-state process (such as a thermal blanket, induction type process, etc), or, a fusion process (YG laser, plasma torch, etc.) The separation of the heating, stirring, forging elements of the process allows more degrees of freedom for greater process control. This paper introduces the mechanics of the thermal stir welding process. In addition, weld mechanical property data is presented for selected alloys as well as metallurgical analysis.

  13. Sustainability of Welding Process through Bobbin Friction Stir Welding

    Science.gov (United States)

    Sued, M. K.; Samsuri, S. S. M.; Kassim, M. K. A. M.; Nasir, S. N. N. M.

    2018-03-01

    Welding process is in high demand, which required a competitive technology to be adopted. This is important for sustaining the needs of the joining industries without ignoring the impact of the process to the environment. Friction stir welding (FSW) is stated to be benefitting the environment through low energy consumption, which cannot be achieved through traditional arc welding. However, this is not well documented, especially for bobbin friction stir welding (BFSW). Therefore, an investigation is conducted by measuring current consumption of the machine during the BFSW process. From the measurement, different phases of BFSW welding process and its electrical demand are presented. It is found that in general total energy in BFSW is about 130kW inclusive of all identified process phases. The phase that utilise for joint formation is in weld phase that used the highest total energy of 120kWs. The recorded total energy is still far below the traditional welding technology and the conventional friction stir welding (CFSW) energy demand. This indicates that BFSW technology with its vast benefit able to sustain the joining technology in near future.

  14. Enabling high speed friction stir welding of aluminum tailor welded blanks

    Science.gov (United States)

    Hovanski, Yuri

    Current welding technologies for production of aluminum tailor-welded blanks (TWBs) are utilized in low-volume and niche applications, and have yet to be scaled for the high-volume vehicle market. This study targeted further weight reduction, part reduction, and cost savings by enabling tailor-welded blank technology for aluminum alloys at high-volumes. While friction stir welding (FSW) has traditionally been applied at linear velocities less than one meter per minute, high volume production applications demand the process be extended to higher velocities more amenable to cost sensitive production environments. Unfortunately, weld parameters and performance developed and characterized at low to moderate welding velocities do not directly translate to high speed linear friction stir welding. Therefore, in order to facilitate production of high volume aluminum FSW components, parameters were developed with a minimum welding velocity of three meters per minute. With an emphasis on weld quality, welded blanks were evaluated for post-weld formability using a combination of numerical and experimental methods. Evaluation across scales was ultimately validated by stamping full-size production door inner panels made from dissimilar thickness aluminum tailor-welded blanks, which provided validation of the numerical and experimental analysis of laboratory scale tests.

  15. Perioperative nursing for patients with diabetic foot receiving endovascular interventional therapy

    International Nuclear Information System (INIS)

    Yang Yang; Wang Feng; Li Ke; Li Cheng; Ji Donghua

    2010-01-01

    Objective: To study the effect of perioperative nursing on the living quality of patients with diabetic foot who are treated with endovascular interventional therapy. Methods: Specific perioperative nursing care plan was accordingly designed for 43 patients with diabetic foot. Endovascular balloon angioplasty and stent implantation were formed in these patients to treat their diabetic foot. The clinical results were observed. Results: Perioperative nursing effectively improved patient's limb blood supply, enhanced the healing of diabetic foot ulceration and increased the possibility of limb preservation. Conclusion: Endovascular therapy combined with corresponding perioperative nursing care can benefit more patients with diabetic foot. (authors)

  16. The Influence of Friction Stir Weld Tool Form and Welding Parameters on Weld Structure and Properties: Nugget Bulge in Self-Reacting Friction Stir Welds

    Science.gov (United States)

    Schneider, Judy; Nunes, Arthur C., Jr.; Brendel, Michael S.

    2010-01-01

    Although friction stir welding (FSW) was patented in 1991, process development has been based upon trial and error and the literature still exhibits little understanding of the mechanisms determining weld structure and properties. New concepts emerging from a better understanding of these mechanisms enhance the ability of FSW engineers to think about the FSW process in new ways, inevitably leading to advances in the technology. A kinematic approach in which the FSW flow process is decomposed into several simple flow components has been found to explain the basic structural features of FSW welds and to relate them to tool geometry and process parameters. Using this modelling approach, this study reports on a correlation between the features of the weld nugget, process parameters, weld tool geometry, and weld strength. This correlation presents a way to select process parameters for a given tool geometry so as to optimize weld strength. It also provides clues that may ultimately explain why the weld strength varies within the sample population.

  17. Endovascular management of inferior vena cava filter thrombotic occlusion.

    Science.gov (United States)

    Branco, Bernardino C; Montero-Baker, Miguel F; Espinoza, Eduardo; Gamero, Maria; Zea-Vera, Rodrigo; Labropoulos, Nicos; Leon, Luis R

    2018-01-01

    Objective Inferior vena cava occlusion is a potentially life-threatening complication related to caval filters. We present our experience with filter-induced inferior vena cava occlusion in order to assess the feasibility, safety, and effectiveness of endovascular management. Methods A retrospective review of all patients undergoing inferior vena cava filter placement over a 60-month study period was performed. From this cohort, a total of 10 cases of inferior vena cava occlusion after filter placement were identified. Demographics, clinical data, procedures, and outcomes were extracted. Patients were followed to the last clinic visit or until they died. Results One-hundred eighty filters were placed by our group practice during the study period. Of those, a total of 10 patients were identified. Overall, there were 7 males; the mean age was 57.1 years (25-78 years). The median time between inferior vena cava filter placement and filter occlusion was 105 days (range 5-4745 days). All patients were clinically symptomatic at the time of their presentation. Nine out of 10 patients were successfully managed endovascularly. Trellis™-8 thrombectomy was the most common endovascular strategy performed ( n = 9). Four patients had balloon angioplasty, two of those with stent placement for chronically occluded inferior vena cava/iliac veins. No thromboembolic complications developed during a median follow-up period of 233 days (range 4-1083 days). Conclusions Endovascular management of inferior vena cava occlusion is feasible, safe, and effective in decreasing thrombus burden in the presence of an inferior vena cava filter. Further studies evaluating long-term inferior vena cava patency and optimal surveillance regimen after endovascular management of filter-related inferior vena cava occlusion are warranted.

  18. A Novel Technique for Endovascular Removal of Large Volume Right Atrial Tumor Thrombus

    Energy Technology Data Exchange (ETDEWEB)

    Nickel, Barbara, E-mail: nickel.ba@gmail.com [US Teleradiology and Quantum Medical Radiology Group (United States); McClure, Timothy, E-mail: tmcclure@gmail.com; Moriarty, John, E-mail: jmoriarty@mednet.ucla.edu [UCLA Medical Center, Department of Interventional Radiology (United States)

    2015-08-15

    Venous thromboembolic disease is a significant cause of morbidity and mortality, particularly in the setting of large volume pulmonary embolism. Thrombolytic therapy has been shown to be a successful treatment modality; however, its use somewhat limited due to the risk of hemorrhage and potential for distal embolization in the setting of large mobile thrombi. In patients where either thrombolysis is contraindicated or unsuccessful, and conventional therapies prove inadequate, surgical thrombectomy may be considered. We present a case of percutaneous endovascular extraction of a large mobile mass extending from the inferior vena cava into the right atrium using the Angiovac device, a venovenous bypass system designed for high-volume aspiration of undesired endovascular material. Standard endovascular methods for removal of cancer-associated thrombus, such as catheter-directed lysis, maceration, and exclusion, may prove inadequate in the setting of underlying tumor thrombus. Where conventional endovascular methods either fail or are unsuitable, endovascular thrombectomy with the Angiovac device may be a useful and safe minimally invasive alternative to open resection.

  19. A Novel Technique for Endovascular Removal of Large Volume Right Atrial Tumor Thrombus

    International Nuclear Information System (INIS)

    Nickel, Barbara; McClure, Timothy; Moriarty, John

    2015-01-01

    Venous thromboembolic disease is a significant cause of morbidity and mortality, particularly in the setting of large volume pulmonary embolism. Thrombolytic therapy has been shown to be a successful treatment modality; however, its use somewhat limited due to the risk of hemorrhage and potential for distal embolization in the setting of large mobile thrombi. In patients where either thrombolysis is contraindicated or unsuccessful, and conventional therapies prove inadequate, surgical thrombectomy may be considered. We present a case of percutaneous endovascular extraction of a large mobile mass extending from the inferior vena cava into the right atrium using the Angiovac device, a venovenous bypass system designed for high-volume aspiration of undesired endovascular material. Standard endovascular methods for removal of cancer-associated thrombus, such as catheter-directed lysis, maceration, and exclusion, may prove inadequate in the setting of underlying tumor thrombus. Where conventional endovascular methods either fail or are unsuitable, endovascular thrombectomy with the Angiovac device may be a useful and safe minimally invasive alternative to open resection

  20. Endovascular Treatment of Various Aortic Pathologies: Review of the Latest Data and Technologies.

    Science.gov (United States)

    Maeda, Koji; Ohki, Takao; Kanaoka, Yuji

    2018-06-01

    The technologies and innovations applicable to endovascular treatment for complex aortic pathologies have progressed rapidly over the last two decades. Although the initial outcomes of an endovascular aortic repair have been excellent, as long-term data became available, complications including endoleaks, endograft migration, and endograft infection have become apparent and are of concern. Previously, the indication for endovascular therapy was restricted to descending thoracic aortic aneurysms and abdominal aortic aneurysms. However, its indication has expanded along with the improvement of techniques and devices, and currently, it has become possible to treat pararenal aortic aneurysms and Crawford type 4 thoracoabdominal aortic aneurysm (TAAA) using the off-the-shelf devices. Additionally, custom-made devices allow for the treatment of arch or more extensive TAAAs. Endovascular treatment is applied not only to aneurysms but also to acute/chronic dissections. However, long-term outcomes are still unclear. This article provides an overview of available devices and the results of endovascular treatment for various aortic pathologies.

  1. Endovascular Treatment of Traumatic Pseudoaneurysm Presenting as Intractable Epistaxis

    International Nuclear Information System (INIS)

    Zhang, Chang wei; Xie, Xiao dong; You, Chao; Mao, Bo yong; Wang, Chao hua; He, Min; Sun, Hong

    2010-01-01

    To investigate the clinical efficacy of individual endovascular management for the treatment of different traumatic pseudo aneurysms presenting as intractable epistaxis. For 14 consecutive patients with traumatic pseudo aneurysm presenting as refractory epistaxis, 15 endovascular procedures were performed. Digital subtraction angiography revealed that the pseudo aneurysms originated from the internal maxillary artery in eight patients; and all were treated with occlusion of the feeding artery. In six cases, they originated from the internal carotid artery (Inca); out of which, two were managed with detachable balloons, two with covered s tents, one by means of cavity embolization, and the remaining one with parent artery occlusion. All of these cases were followed up clinically from six to 18 months, with a mean follow up time of ten months; moreover, three cases were also followed with angiography. Complete cessation of bleeding was achieved in all the 15 instances (100%) immediately after the endovascular therapies. Of the six patients who suffered from Inca pseudo aneurysms, one presented with a permanent stroke and one had an episode of rebleeding requiring intervention. In patients presenting with a history of cranio cerebral trauma, traumatic pseudo aneurysm must be considered as a differential diagnosis. Individual endovascular treatment is a relatively safe, plausible, and reliable means of managing traumatic pseudo aneurysms

  2. Endovascular treatment of ruptured true posterior communicating artery aneurysms.

    Science.gov (United States)

    Yang, Yonglin; Su, Wandong; Meng, Qinghai

    2015-01-01

    Although true posterior communicating artery (PCoA) aneurysms are rare, they are of vital importance. We reviewed 9 patients with this fatal disease, who were treated with endovascular embolization, and discussed the meaning of endovascular embolization for the treatment of true PCoA aneurysms. From September 2006 to May 2012, 9 patients with digital substraction angiography (DSA) confirmed true PCoA aneurysms were treated with endovascular embolization. Patients were followed-up with a minimal duration of 17 months and assessed by Glasgow Outcome Scale (GOS) score. All the patients presented with spontaneous subarachnoid hemorrhage from the ruptured aneurysms. The ratio of males to females was 1:2, and the average age of onset was 59.9 (ranging from 52 to 72) years. The preoperative Hunt-Hess grade scores were I to III. All patients had recovered satisfactorily. No permanent neurological deficits were left. Currently, endovascular embolization can be recommended as the top choice for the treatment of most true PCoA aneurysms, due to its advanced technique, especially the application of the stent-assisted coiling technique, combined with its advantage of mininal invasiveness and quick recovery. However, the choice of treatment methods should be based on the clinical and anatomical characteristics of the aneurysm and the skillfulness of the surgeon.

  3. Endovascular Treatment of Traumatic Pseudoaneurysm Presenting as Intractable Epistaxis

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Chang wei; Xie, Xiao dong; You, Chao; Mao, Bo yong; Wang, Chao hua; He, Min; Sun, Hong [Sichuan University West China Hospital, Chengdu (China)

    2010-12-15

    To investigate the clinical efficacy of individual endovascular management for the treatment of different traumatic pseudo aneurysms presenting as intractable epistaxis. For 14 consecutive patients with traumatic pseudo aneurysm presenting as refractory epistaxis, 15 endovascular procedures were performed. Digital subtraction angiography revealed that the pseudo aneurysms originated from the internal maxillary artery in eight patients; and all were treated with occlusion of the feeding artery. In six cases, they originated from the internal carotid artery (Inca); out of which, two were managed with detachable balloons, two with covered s tents, one by means of cavity embolization, and the remaining one with parent artery occlusion. All of these cases were followed up clinically from six to 18 months, with a mean follow up time of ten months; moreover, three cases were also followed with angiography. Complete cessation of bleeding was achieved in all the 15 instances (100%) immediately after the endovascular therapies. Of the six patients who suffered from Inca pseudo aneurysms, one presented with a permanent stroke and one had an episode of rebleeding requiring intervention. In patients presenting with a history of cranio cerebral trauma, traumatic pseudo aneurysm must be considered as a differential diagnosis. Individual endovascular treatment is a relatively safe, plausible, and reliable means of managing traumatic pseudo aneurysms

  4. Endovascular Treatment of Traumatic Pseudoaneurysm Presenting as Intractable Epistaxis

    Science.gov (United States)

    Zhang, Chang wei; You, Chao; Mao, Bo yong; Wang, Chao hua; He, Min; Sun, Hong

    2010-01-01

    Objective To investigate the clinical efficacy of individual endovascular management for the treatment of different traumatic pseudoaneurysms presenting as intractable epistaxis. Materials and Methods For 14 consecutive patients with traumatic pseudoaneurysm presenting as refractory epistaxes, 15 endovascular procedures were performed. Digital subtraction angiography revealed that the pseudoaneurysms originated from the internal maxillary artery in eight patients; and all were treated with occlusion of the feeding artery. In six cases, they originated from the internal carotid artery (ICA); out of which, two were managed with detachable balloons, two with covered stents, one by means of cavity embolization, and the remaining one with parent artery occlusion. All of these cases were followed up clinically from six to 18 months, with a mean follow up time of ten months; moreover, three cases were also followed with angiography. Results Complete cessation of bleeding was achieved in all the 15 instances (100%) immediately after the endovascular therapies. Of the six patients who suffered from ICA pseudoaneurysms, one presented with a permanent stroke and one had an episode of rebleeding requiring intervention. Conclusion In patients presenting with a history of craniocerebral trauma, traumatic pseudoaneurysm must be considered as a differential diagnosis. Individual endovascular treatment is a relatively safe, plausible, and reliable means of managing traumatic pseudoaneurysms. PMID:21076585

  5. Total Endovascular Aortic Repair in a Patient with Marfan Syndrome.

    Science.gov (United States)

    Amako, Mau; Spear, Rafaëlle; Clough, Rachel E; Hertault, Adrien; Azzaoui, Richard; Martin-Gonzalez, Teresa; Sobocinski, Jonathan; Haulon, Stéphan

    2017-02-01

    The aim of this study is to describe a total endovascular aortic repair with branched and fenestrated endografts in a young patient with Marfan syndrome and a chronic aortic dissection. Open surgery is the gold standard to treat aortic dissections in patients with aortic disease and Marfan syndrome. In 2000, a 38-year-old man with Marfan syndrome underwent open ascending aorta repair for an acute type A aortic dissection. One year later, a redo sternotomy was performed for aortic valve replacement. In 2013, the patient presented with endocarditis and pulmonary infection, which necessitated tracheostomy and temporary dialysis. In 2014, the first stage of the endovascular repair was performed using an inner branched endograft to exclude a 77-mm distal arch and descending thoracic aortic aneurysm. In 2015, a 63-mm thoracoabdominal aortic aneurysm was excluded by implantation of a 4-fenestrated endograft. Follow-up after both endovascular repairs was uneventful. Total aortic endovascular repair was successfully performed to treat a patient with arch and thoraco-abdominal aortic aneurysm associated with chronic aortic dissection and Marfan syndrome. The postoperative images confirmed patency of the endograft and its branches, and complete exclusion of the aortic false lumen. Endovascular repair is a treatment option in patients with connective tissue disease who are not candidates for open surgery. Long-term follow-up is required to confirm these favorable early outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Predictive factors for cerebrovascular accidents after thoracic endovascular aortic repair.

    Science.gov (United States)

    Mariscalco, Giovanni; Piffaretti, Gabriele; Tozzi, Matteo; Bacuzzi, Alessandro; Carrafiello, Giampaolo; Sala, Andrea; Castelli, Patrizio

    2009-12-01

    Cerebrovascular accidents are devastating and worrisome complications after thoracic endovascular aortic repair. The aim of this study was to determine cerebrovascular accident predictors after thoracic endovascular aortic repair. Between January 2001 and June 2008, 76 patients treated with thoracic endovascular aortic repair were prospectively enrolled. The study cohort included 61 men; mean age was 65.4 +/- 16.8 years. All patients underwent a specific neurologic assessment on an hourly basis postoperatively to detect neurologic deficits. Cerebrovascular accidents were diagnosed on the basis of physical examination, tomography scan or magnetic resonance imaging, or autopsy. Cerebrovascular accidents occurred in 8 (10.5%) patients, including 4 transient ischemic attack and 4 major strokes. Four cases were observed within the first 24-hours. Multivariable analysis revealed that anatomic incompleteness of the Willis circle (odds ratio [OR] 17.19, 95% confidence interval [CI] 2.10 to 140.66), as well as the presence of coronary artery disease (OR 6.86, 95 CI% 1.18 to 40.05), were independently associated with postoperative cerebrovascular accident development. Overall hospital mortality was 9.2%, with no significant difference for patients hit by cerebrovascular accidents (25.0% vs 7.3%, p = 0.102). Preexisting coronary artery disease, reflecting a severe diseased aorta and anomalies of Willis circle are independent cerebrovascular accident predictors after thoracic endovascular aortic repair procedures. A careful evaluation of the arch vessels and cerebral vascularization should be mandatory for patients suitable for thoracic endovascular aortic repair.

  7. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1995-09-15

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy.

  8. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    International Nuclear Information System (INIS)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae

    1995-01-01

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy

  9. Automatic orbital GTAW welding: Highest quality welds for tomorrow's high-performance systems

    Science.gov (United States)

    Henon, B. K.

    1985-01-01

    Automatic orbital gas tungsten arc welding (GTAW) or TIG welding is certain to play an increasingly prominent role in tomorrow's technology. The welds are of the highest quality and the repeatability of automatic weldings is vastly superior to that of manual welding. Since less heat is applied to the weld during automatic welding than manual welding, there is less change in the metallurgical properties of the parent material. The possibility of accurate control and the cleanliness of the automatic GTAW welding process make it highly suitable to the welding of the more exotic and expensive materials which are now widely used in the aerospace and hydrospace industries. Titanium, stainless steel, Inconel, and Incoloy, as well as, aluminum can all be welded to the highest quality specifications automatically. Automatic orbital GTAW equipment is available for the fusion butt welding of tube-to-tube, as well as, tube to autobuttweld fittings. The same equipment can also be used for the fusion butt welding of up to 6 inch pipe with a wall thickness of up to 0.154 inches.

  10. Influence of Welding Process and Post Weld Heat Treatment on Microstructure and Pitting Corrosion Behavior of Dissimilar Aluminium Alloy Welds

    Science.gov (United States)

    Venkata Ramana, V. S. N.; Mohammed, Raffi; Madhusudhan Reddy, G.; Srinivasa Rao, K.

    2018-03-01

    Welding of dissimilar Aluminum alloy welds is becoming important in aerospace, shipbuilding and defence applications. In the present work, an attempt has been made to weld dissimilar aluminium alloys using conventional gas tungsten arc welding (GTAW) and friction stir welding (FSW) processes. An attempt was also made to study the effect of post weld heat treatment (T4 condition) on microstructure and pitting corrosion behaviour of these welds. Results of the present investigation established the differences in microstructures of the base metals in T4 condition and in annealed conditions. It is evident that the thickness of the PMZ is relatively more on AA2014 side than that of AA6061 side. In FS welds, lamellar like shear bands are well noticed on the top of the stir zone. The concentration profile of dissimilar friction stir weld in T4 condition revealed that no diffusion has taken place at the interface. Poor Hardness is observed in all regions of FS welds compared to that of GTA welds. Pitting corrosion resistance of the dissimilar FS welds in all regions was improved by post weld heat treatment.

  11. A control system for uniform bead in fillet arc welding on tack welds

    International Nuclear Information System (INIS)

    Kim, Jae Woong; Lee, Jun Young

    2008-01-01

    Positioning a workpiece accurately and preventing weld distortion, tack welding is often adopted before main welding in the construction of welded structures. However, this tack weld deteriorates the final weld bead profile, so that the grinding process is usually performed for a uniform weld bead profile. In this study, a control system for uniform weld bead is proposed for the fillet arc welding on tack welds. The system consists of GMA welding machine, torch manipulator, laser vision sensor for measuring the tack weld size and the database for optimal welding conditions. Experiments have been performed for constructing the database and for evaluating the control capability of the system. It has been shown that the system has the capability to smooth the bead at the high level of quality

  12. Torque Measurement of Welding of Endplug-Endplate using Multi-pin Remote Welding System

    Energy Technology Data Exchange (ETDEWEB)

    Koo, Dae-Seo; Kim, Soo-Sung; Park, Geun-Il; Lee, Jung-Won; Song, Kee-Chan [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2006-07-01

    As fuel bundles in PHWR irradiates, inner pressure in claddings of fuel rods increases owing to outer pressure and fission products of nuclear fissions. Because of leak possibility of welding between cladding and end plug, this welding part connects with safety of nuclear fuel rods. Because of importance of this welding part, weldability of end plug-cladding of nuclear fuel rods is continually researched. Welding method for research and commercialization is classified as melting, solid type welding or resistance welding. End plug cladding welding of nuclear fuel rods in PHWR takes advantage of resistance upset butt welding using multicycle mode. This method makes weld flash and shapes re-entrant corner owing to welding heat due to resistivity, contact resistance of cladding-end plug, and inelasticity deformation due to pressure. Welding part between cladding and end plug receives stresses and makes small cracks. In this study, remote welding system for multi-pin assembly was designed, fabricated and welding specimens of end plug-endplate were made using electrical resistance method. The torques of welding between end plug and endplate were measured. These results on welding current, pressure of main electrode and pressure of branch electrode were analyzed. Weldability between end plug and endplate was confirmed through metallographic examinations. In the future, optimal welding examinations due to welding current, welding pressure and welding time will be performed to improve weldability of end plug-endplate.

  13. Advantages of new micro-jet welding technology on weld microstructure control

    Directory of Open Access Journals (Sweden)

    Jan PIWNIK

    2013-01-01

    Full Text Available An innovative apparatus to welding process with micro-jet cooling of the weld made it possible to carry out technological tests, which have proved theoretical considerations about this problem. This project gives real opportunities for professional development in the field of welding with controlling the parameters of weld structure. These tests have proved that the new micro-jet technology has the potential for growth. It may be great achievement of welding technology in order to increase weld metal strength. The new technology with micro-jet cooling may have many practical applications in many fields, for example such as in the transport industry or to repair damaged metal elements. The advantages of the new device over the traditional system are the ability to control the structure of the weld, the weld mechanical performance increases and improve the quality of welded joints.

  14. Identifying patients with AAA with the highest risk following endovascular repair.

    Science.gov (United States)

    Cadili, Ali; Turnbull, Robert; Hervas-Malo, Marilou; Ghosh, Sunita; Chyczij, Harold

    2012-08-01

    It has been demonstrated that endovascular repair of arterial disease results in reduced perioperative morbidity and mortality compared to open surgical repair. The rates of complications and need for reinterventions, however, have been found to be higher than that in open repair. The purpose of this study was to identify the predictors of endograft complications and mortality in patients undergoing endovascular abdominal aortic aneurysm (AAA) repair; specifically, our aim was to identify a subset of patients with AAA whose risk of periprocedure mortality was so high that they should not be offered endovascular repair. We undertook a prospective review of patients with AAA receiving endovascular therapy at a single institution. Collected variables included age, gender, date of procedure, indication for procedure, size of aneurysm (where applicable), type of endograft used, presence of rupture, American Society of Anesthesiologists (ASA) class, major medical comorbidities, type of anesthesia (general, epidural, or local), length of intensive care unit (ICU) stay, and length of hospital stay. These factors were correlated with the study outcomes (overall mortality, graft complications, morbidity, and reintervention) using univariate and multivariate logistic regression. A total of 199 patients underwent endovascular AAA repair during the study period. The ICU stay, again, was significantly correlated with the primary outcomes (death and graft complications). In addition, length of hospital stay greater than 3 days, also emerged as a statistically significant predictor of graft complications in this subgroup (P = .024). Survival analysis for patients with AAA revealed that age over 85 years and ICU stay were predictive of decreased survival. Statistical analysis for other subgroups of patients (inflammatory AAA or dissection) was not performed due to the small numbers in these subgroups. Patients with AAA greater than 85 years of age are at a greater risk of mortality

  15. Emergency endovascular management of peripheral artery aneurysms and pseudoaneurysms – a review

    Directory of Open Access Journals (Sweden)

    Gillard Jonathan H

    2008-07-01

    Full Text Available Abstract Endovascular stenting has been successfully employed in the management of aortic aneurysms; however, its use in managing peripheral arterial conditions remains questionable. We review the utility of endovascular technique in the management of peripheral arterial conditions like aneurysms, pseudoaneurysms and arterio-venous fistulas in the emergency setting. Though long term data about graft patency rates is not yet available, the endovascular approach appears to be a useful minimally invasive technique in situations where open repair is either difficult or not feasible.

  16. Supra-aortic interventions for endovascular exclusion of the entire aortic arch.

    Science.gov (United States)

    Andrási, Terézia B; Grossmann, Marius; Zenker, Dieter; Danner, Bernhard C; Schöndube, Friedrich A

    2017-07-01

    Our aim was to analyze the outcomes of endovascular exclusion of the entire aortic arch (proximal landing in zone 0, distal landing in zone III or beyond, after Ishimaru) in which complete surgical debranching of the supra-aortic vessels (I), endovascular supra-aortic revascularization (chimney, fenestrated, or branched grafts) with partial surgical debranching (II), or total endovascular supra-aortic revascularization (III) was additionally performed. Publications describing endovascular repair of the aortic arch (2000-2016) were systematically searched and reviewed. From a total of 53 relevant studies including 1853 patients, only 1021 patients undergoing 35 different total aortic arch procedures were found eligible for further evaluation and included in group I, II, or III (429, 190, and 402 patients, respectively). Overall early mortality was higher in group I vs groups II and III (P = .001; 1 - β = 95.6%) but exceeded in group III (18.6%) and group II (14.0%) vs group I (8.0%; P = .044; 1 - β = 57.4%) for diseases involving zone 0. Mortality was higher in all subgroups treated for zone 0 disease compared with corresponding subgroups treated for zone I to zone III disease. The incidence of cerebral ischemic events was increased in groups I and II vs group III (7.5% and 11% vs 1.7%; P = .0001) and correlated with early mortality (R 2  = .20; P = .033). The incidence of type II endoleaks and endovascular reintervention was similar between groups and correlated with each other (R 2  = .37; P = .004). Type Ia endoleak occurred more often in groups II and III than in group I (7.1% and 12.1% vs 5.8%; P = .023) and correlated with midterm mortality (R 2  = .53; P = .005). Retrograde type A dissection was low in all groups, whereas aneurysm growth was higher in group III (2.6%, 4.2%, 10.7%; P = .002), correlating with midterm mortality (R 2  = .311; P = .009). Surgical revision slightly correlated with surgical complications (R 2  = .18; P = .044

  17. Current status of endovascular catheter robotics.

    Science.gov (United States)

    Lumsden, Alan B; Bismuth, Jean

    2018-06-01

    In this review, we will detail the evolution of endovascular therapy as the basis for the development of catheter-based robotics. In parallel, we will outline the evolution of robotics in the surgical space and how the convergence of technology and the entrepreneurs who push this evolution have led to the development of endovascular robots. The current state-of-the-art and future directions and potential are summarized for the reader. Information in this review has been drawn primarily from our personal clinical and preclinical experience in use of catheter robotics, coupled with some ground-breaking work reported from a few other major centers who have embraced the technology's capabilities and opportunities. Several case studies demonstrating the unique capabilities of a precisely controlled catheter are presented. Most of the preclinical work was performed in the advanced imaging and navigation laboratory. In this unique facility, the interface of advanced imaging techniques and robotic guidance is being explored. Although this procedure employs a very high-tech approach to navigation inside the endovascular space, we have conveyed the kind of opportunities that this technology affords to integrate 3D imaging and 3D control. Further, we present the opportunity of semi-autonomous motion of these devices to a target. For the interventionist, enhanced precision can be achieved in a nearly radiation-free environment.

  18. TECHNOLOGICAL ISSUES IN MECHANISED FEED WIG/TIG WELDING SURFACING OF WELDING

    Directory of Open Access Journals (Sweden)

    BURCA Mircea

    2016-09-01

    manual welding tests in the light of using the process for welding surfacing being known that in such applications mechanised operations are recommended whenever possible given the latter strengths i.e. increased productivity and quality deposits. The research also aims at achieving a comparative a study between wire mechanised feed based WIG manual welding and the manual rod entry based manual welding in terms of geometry deposits, deposits aesthetics, operating technique, productivity, etc . In this regard deposits were made by means of two welding procedures, and subsequently welding surfacing was made with the optimum values of the welding parameters in this case.

  19. Advances in endovascular treatment of critical limb ischemia.

    LENUS (Irish Health Repository)

    Yan, Bryan P

    2011-04-01

    Critical limb ischemia (CLI) represents the most severe clinical manifestation of peripheral arterial disease. In the absence of timely revascularization, CLI carries high risk of mortality and amputation. Over the past decade, endovascular revascularization has rapidly become the preferred primary treatment strategy for CLI, especially for the treatment of below-the-knee disease. Advances in percutaneous devices and techniques have expanded the spectrum of patients with CLI who are deemed candidates for revascularization. This review will focus on advances in endovascular options for the treatment of CLI, in particular for below-the-knee disease.

  20. Enhancing brain lesions after endovascular treatment of aneurysms

    DEFF Research Database (Denmark)

    Cruz, J P; Marotta, T; O'Kelly, C

    2014-01-01

    present 7 patients from 5 different institutions that developed MR imaging-enhancing brain lesions after endovascular therapy of aneurysms, detected after a median time of 63 days. The number of lesions ranged from 4-46 (median of 10.5), sized 2-20 mm, and were mostly in the same vascular territory used......Complications of endovascular therapy of aneurysms mainly include aneurysm rupture and thromboembolic events. The widespread use of MR imaging for follow-up of these patients revealed various nonvascular complications such as aseptic meningitis, hydrocephalus, and perianeurysmal brain edema. We...

  1. Analyzing the Safeguarding Our Communities Act: Patch for Patch Return Policy in Ontario

    Directory of Open Access Journals (Sweden)

    Soo-Min Kim

    2018-04-01

    Full Text Available Fentanyl is prescribed to patients suffering from severe chronic pain. Transdermal patches are the best mode of delivery for patients who have developed tolerance for opioids. However, used patches still contain fentanyl that can be extracted and misused, with potentially severe consequences. To address this issue, patients who are prescribed fentanyl patches in Ontario are now required to return previously dispensed patches to receive new patches under the Safeguarding Our Communities Act: Patch for Patch (P4P Return Policy. The problem is significant in Ontario because the province has the largest annual dispense rate of high-dose prescription fentanyl (112 units per 1,000 population in Canada even though the prevalence rate of chronic pain is lower than the national reported range (16.6% in Ontario versus 19.6 to 21.9% in other provinces, according to Gomes et al. 2014. The primary goal of this reform is to instill responsible use of fentanyl patches, and to improve safety for patients and the public by having a central disposal process. The reform was modeled after a community initiative that was pioneered in North Bay after receiving great support from health professional colleges and communities that voluntarily integrated the program prior to the introduction of Bill 33. Preliminary data suggest that the P4P policy is positively received by health professionals, although ongoing evaluation is needed to assess the effectiveness of the policy in reducing misuse and abuse of prescribed fentanyl patches.

  2. Outcomes of Infrainguinal Revascularizations with Endovascular First Strategy in Critical Limb Ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Jens, Sjoerd, E-mail: s.jens@amc.uva.nl [Academic Medical Center, Department of Radiology (Netherlands); Conijn, Anne P., E-mail: a.p.conijn@amc.uva.nl; Frans, Franceline A., E-mail: f.a.frans@amc.uva.nl [Academic Medical Center, Departments of Radiology and Surgery (Netherlands); Nieuwenhuis, Marieke B. B., E-mail: m.b.nieuwenhuis@amc.uva.nl; Met, Rosemarie, E-mail: rosemariemet@hotmail.com [Academic Medical Center, Department of Radiology (Netherlands); Koelemay, Mark J. W., E-mail: m.j.koelemaij@amc.uva.nl; Legemate, Dink A., E-mail: d.a.legemate@amc.uva.nl [Academic Medical Center, Department of Surgery (Netherlands); Bipat, Shandra, E-mail: s.bipat@amc.uva.nl; Reekers, Jim A., E-mail: j.a.reekers@amc.uva.nl [Academic Medical Center, Department of Radiology (Netherlands)

    2015-06-15

    PurposeThis study was designed to study the outcome of infrainguinal revascularization in patients with critical limb ischemia (CLI) in an institution with a preference towards endovascular intervention first in patients with poor condition, unfavourable anatomy for surgery, no venous material for bypass, and old age.MethodsA prospective, observational cohort study was conducted between May 2007 and May 2010 in patients presenting with CLI. At baseline, the optimal treatment was selected, i.e., endovascular or surgical treatment. In case of uncertainty about the preferred treatment, a multidisciplinary team (MDT) was consulted. Primary endpoints were quality of life and functional status 6 and 12 months after initial intervention, assessed by the VascuQol and AMC Linear Disability Score questionnaires, respectively.ResultsIn total, 113 patients were included; 86 had an endovascular intervention and 27 had surgery. During follow-up, 41 % underwent an additional ipsilateral revascularisation procedure. For the total population, and endovascular and surgery subgroups, the VascuQol sum scores improved after 6 and 12 months (p < 0.01 for all outcomes) compared with baseline. The functional status improved (p = 0.043) after 12 months compared with baseline for the total population. Functional status of the surgery subgroup improved significantly after 6 (p = 0.031) and 12 (p = 0.044) months, but not that of the endovascular subgroup.ConclusionsOverall, the strategy of performing endovascular treatment first in patients with poor condition, unfavourable anatomy for surgery, no venous material for bypass, and old age has comparable or even slightly better results compared with the BASIL trial and other cohort studies. All vascular groups should discuss whether their treatment strategy should be directed at treating CLI patients preferably endovascular first and consider implementing an MDT to optimize patient outcomes.

  3. Welding Penetration Control of Fixed Pipe in TIG Welding Using Fuzzy Inference System

    Science.gov (United States)

    Baskoro, Ario Sunar; Kabutomori, Masashi; Suga, Yasuo

    This paper presents a study on welding penetration control of fixed pipe in Tungsten Inert Gas (TIG) welding using fuzzy inference system. The welding penetration control is essential to the production quality welds with a specified geometry. For pipe welding using constant arc current and welding speed, the bead width becomes wider as the circumferential welding of small diameter pipes progresses. Having welded pipe in fixed position, obviously, the excessive arc current yields burn through of metals; in contrary, insufficient arc current produces imperfect welding. In order to avoid these errors and to obtain the uniform weld bead over the entire circumference of the pipe, the welding conditions should be controlled as the welding proceeds. This research studies the intelligent welding process of aluminum alloy pipe 6063S-T5 in fixed position using the AC welding machine. The monitoring system used a charge-coupled device (CCD) camera to monitor backside image of molten pool. The captured image was processed to recognize the edge of molten pool by image processing algorithm. Simulation of welding control using fuzzy inference system was constructed to simulate the welding control process. The simulation result shows that fuzzy controller was suitable for controlling the welding speed and appropriate to be implemented into the welding system. A series of experiments was conducted to evaluate the performance of the fuzzy controller. The experimental results show the effectiveness of the control system that is confirmed by sound welds.

  4. Stroke Neurologist's Perspective on the New Endovascular Trials.

    Science.gov (United States)

    Grotta, James C; Hacke, Werner

    2015-06-01

    Before December 2014, the only proven effective treatment for acute ischemic stroke was recombinant tissue-type plasminogen activator (r-tPA). This has now changed with the publication of the Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands (MR CLEAN), Endovascular Treatment for Small Core and Anterior Circulation Proximal Occlusion With Emphasis on Minimizing CT to Recanalization Times (ESCAPE), Extending the Time for Thrombolysis in Emergency Neurological Deficits--Intra-Arterial (EXTEND IA), Solitaire With the Intention for Thrombectomy as Primary Endovascular Treatment Trial (SWIFT PRIME), and Randomized Trial of Revascularization With the Solitaire FR Device Versus Best Medical Therapy in the Treatment of Acute Stroke Due to Anterior Circulation Large Vessel Occlusion Presenting Within Eight Hours of Symptom Onset (REVASCAT) studies. We review the main results of these studies and how they inform stroke patient management going forward. The main take home points for neurologists are (1) intra-arterial thrombectomy is a potently effective treatment and should be offered to patients who have documented occlusion in the distal internal carotid or the proximal middle cerebral artery, have a relatively normal noncontrast head computed tomographic scan, severe neurological deficit, and can have intra-arterial thrombectomy within 6 hours of last seen normal; (2) benefits are clear in patients receiving r-tPA before intra-arterial thrombectomy; r-tPA should not be withheld if the patient meets criteria, and benefit in patients who do not receive r-tPA or have r-tPA exclusions requires further study; and (3) these favorable results occur when intra-arterial thrombectomy is performed in an endovascular stroke center by a coordinated multidisciplinary team that extends from the prehospital stage to the endovascular suite, minimizes time to recanalization, uses stent-retriever devices, and avoids general

  5. Versatile Friction Stir Welding/Friction Plug Welding System

    Science.gov (United States)

    Carter, Robert

    2006-01-01

    A proposed system of tooling, machinery, and control equipment would be capable of performing any of several friction stir welding (FSW) and friction plug welding (FPW) operations. These operations would include the following: Basic FSW; FSW with automated manipulation of the length of the pin tool in real time [the so-called auto-adjustable pin-tool (APT) capability]; Self-reacting FSW (SRFSW); SR-FSW with APT capability and/or real-time adjustment of the distance between the front and back shoulders; and Friction plug welding (FPW) [more specifically, friction push plug welding] or friction pull plug welding (FPPW) to close out the keyhole of, or to repair, an FSW or SR-FSW weld. Prior FSW and FPW systems have been capable of performing one or two of these operations, but none has thus far been capable of performing all of them. The proposed system would include a common tool that would have APT capability for both basic FSW and SR-FSW. Such a tool was described in Tool for Two Types of Friction Stir Welding (MFS- 31647-1), NASA Tech Briefs, Vol. 30, No. 10 (October 2006), page 70. Going beyond what was reported in the cited previous article, the common tool could be used in conjunction with a plug welding head to perform FPW or FPPW. Alternatively, the plug welding head could be integrated, along with the common tool, into a FSW head that would be capable of all of the aforementioned FSW and FPW operations. Any FSW or FPW operation could be performed under any combination of position and/or force control.

  6. Effect of Welding Parameters on Dilution and Weld Bead Geometry in Cladding

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The effect of pulsed gas metal arc welding (GMAW) variables on the dilution and weld bead geometry in cladding X65 pipeline steel with 316L stainless steel was studied. Using a full factorial method, a series of experiments were carried out to know the effect of wire feed rate, welding speed, distance between gas nozzle and plate, and the vertical angle of welding on dilution and weld bead geometry. The findings indicate that the dilution of weld metal and its dimension i.e. width, height and depth increase with the feed rate, but the contact angle of the bead decreases first and then increases. Meantime, welding speed has an opposite effect except for dilution. There is an interaction effect between welding parameters at the contact angle. The results also show forehand welding or decreasing electrode extension decrease the angle of contact. Finally,a mathematical model is contrived to highlight the relationship between welding variables with dilution and weld bead geometry.

  7. Modeling of welded bead profile for rapid prototyping by robotic MAG welding

    Institute of Scientific and Technical Information of China (English)

    CAO Yong; ZHU Sheng; WANG Tao; WANG Wanglong

    2009-01-01

    As a deposition technology, robotic metal active gas(MAG) welding has shown new promise for rapid prototyping (RP) of metallic parts. During the process of metal forming using robotic MAG welding, sectional profile of single-pass welded bead is critical to formed accuracy and quality of metal pans. In this paper, the experiments of single-pass welded bead for rapid prototyping using robotic MAG welding were carried out. The effect of some edge detectors on the cross-sectional edge of welded bead was discussed and curve fitting was applied using leat square fitting. Consequently, the mathematical model of welded bead profile was developed. The experimental results show that good shape could be obtained under suitable welding parameters. Canny operawr is suitable to edge detection of welded bead profile, and the mathematical model of welded bead profile developed is approximately parabola.

  8. Fusion welding process

    Science.gov (United States)

    Thomas, Kenneth C.; Jones, Eric D.; McBride, Marvin A.

    1983-01-01

    A process for the fusion welding of nickel alloy steel members wherein a ferrite containing pellet is inserted into a cavity in one member and melted by a welding torch. The resulting weld nugget, a fusion of the nickel containing alloy from the members to be welded and the pellet, has a composition which is sufficiently low in nickel content such that ferrite phases occur within the weld nugget, resulting in improved weld properties. The steel alloys encompassed also include alloys containing carbon and manganese, considered nickel equivalents.

  9. A Matched Case-Control Study on Open and Endovascular Treatment of Popliteal Artery Aneurysms.

    Science.gov (United States)

    Dorigo, W; Fargion, A; Masciello, F; Piffaretti, G; Pratesi, G; Giacomelli, E; Pratesi, C

    2018-01-01

    To compare early and late results of open and endovascular management of popliteal artery aneurysm in a retrospective single-center matched case-control study Methods: From 1981 to 2015, 309 consecutive interventions for popliteal artery aneurysm were performed in our institution, in 59 cases with endovascular repair and in 250 cases with open repair. Endovascular repair was preferred in older asymptomatic patients, while open repair was offered more frequently to patients with a thrombosed popliteal artery aneurysm and a poor run-off status. A one-to-one coarsened exact matching on the basis of the baseline demographic, clinical, and anatomical covariates significantly different between the two treatment options was performed and two equivalent groups of 56 endovascular repairs and open repairs were generated. The two groups were compared in terms of perioperative results with χ 2 test and of follow-up outcomes with the Kaplan-Meier curves and log-rank test. There were no differences between the two groups in terms of perioperative outcomes. Median duration of follow-up was 38 months. Five-year survival rates were 94% in endovascular repair group and 89.5% in open repair group (p = 0.4, log-rank 0.6). Primary patency rates at 1, 3, and 5 years were 81%, 78%, and 72% in endovascular repair group and 82.5%, 80%, and 64% in open repair group (p = 0.8, log-rank 0.01). Freedom from reintervention at 5 years was 65.5% in endovascular repair group and 76% in open repair group (p = 0.2, log-rank 1.2). Secondary patency at 1, 3, and 5 years was 94%, 86%, and 74% in endovascular repair group, and 94%, 89%, and 71% in open repair group, respectively (p = 0.9, log-rank 0.01). The rates of limb preservation at 5 years were 94% in endovascular repair group and 86.4% in open repair group (p = 0.3, log-rank 0.8). Open repair and endovascular repair of popliteal artery aneurysms provided in this retrospective single-center experience similar perioperative and follow-up results in

  10. Actual review of diagnostics and endovascular therapy of intracranial arterial stenoses

    International Nuclear Information System (INIS)

    Gizewski, E.R.; Weber, R.; Forsting, M.

    2011-01-01

    Approximately 6 - 50 % of all ischemic strokes are caused by intracranial arterial stenosis (IAS). Despite medical prevention, patients with symptomatic IAS have a high annual risk for recurrent ischemic stroke of about 12 %, and up to 19 % in the case of high-grade IAS (≥ 70 %). Digital subtraction angiography remains the gold standard for the diagnosis and grading of IAS. However, noninvasive imaging techniques including CT angiography, MR angiography, or transcranial Doppler and duplex ultrasound examinations are used in the clinical routine to provide additional information about the brain structure and hemodynamic. However, for technical reasons, the grading of stenoses is sometimes difficult and inaccurate. To date, aspirin is recommended as the treatment of choice in the prevention of recurrent ischemic stroke in patients with IAS. IAS patients who suffer a recurrent ischemic stroke or transient ischemic attack while taking aspirin can be treated with endovascular stenting or angioplasty in specialized centers. The periprocedural complication rate of these endovascular techniques is about 2 - 7 % at experienced neuro-interventional centers. The rate of re-stenosis is reported between 10 and 40 % depending on patient age and stenosis location. Further randomized studies comparing medical secondary prevention and endovascular therapy are currently being performed. With regard to the improvement of endovascular methods and lower complication rates, the indication for endovascular therapy in IAS could be broadened especially for stenosis in the posterior circulation. (orig.)

  11. Endovascular Aneurysm Repair and Sealing (EVARS): A Useful Adjunct in Treating Challenging Morphology

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Gareth J., E-mail: garethjamesharrison@yahoo.co.uk; Antoniou, George A., E-mail: antoniou.ga@hotmail.com; Torella, Francesco, E-mail: francesco.torella@rlbuht.nhs.uk; McWilliams, Richard G., E-mail: richard.mcwilliams@rlbuht.nhs.uk; Fisher, Robert K., E-mail: robert.fisher@rlbuht.nhs.uk [Royal Liverpool University Hospital, Liverpool Vascular and Endovascular Service (United Kingdom)

    2016-04-15

    An 81-year-old male with previous open abdominal aortic aneurysm repair presented with asymptomatic large pseudoaneurysms at both ends of an open surgical tube graft. Endovascular aneurysm sealing (EVAS) in combination with the iliac limbs of a standard endovascular aneurysm repair (EVAR) successfully excluded both pseudoaneurysms from circulation. We describe the combination of elements of EVAS and EVAR and have termed this endovascular aneurysm repair and sealing (EVARS). EVARS has the advantage of harnessing the benefits of endobag sealing in aortic necks unsuitable for standard EVAR whilst providing the security of accurate stent placement within short common iliac arteries. In conclusion, EVAS may be combined with standard endovascular iliac limbs and is a possible treatment option for pseudoaneurysm following open aneurysm repair.

  12. Endovascular treatment of nutcracker syndrome - a case report

    International Nuclear Information System (INIS)

    Rowinski, O.; Januszewicz, M.; Wojtaszek, M.; Nawrot, I.; Szmidt, J.

    2007-01-01

    The 'nutcracker' syndrome is most commonly caused by arterial compression of the left renal vein between the superior mesenteric artery and the aorta. As a consequence venous blood pressure increases within the renal pelvis, ureter and gonadal veins. This compression syndrome may be treated by endovascular stent implantation into the left renal vein. A 20 year old female patient was referred to us, suffering from pain in her left side, gross proteinuria and the suspicion of 'nutcracker' syndrome. Symptoms were present for the last 3 years. Angio MRI was performed and confirmed compression of the left renal vein between the aorta and the superior mesenteric artery. The patient was qualified for endovascular treatment. A self expandable metallic stent, diameter 16 x 40 mm was implanted into the left renal vein. Control venography confirmed good placement of the stent and a good immediate hemodynamic effect of the procedure. The patient remains symptom free in a 14 month follow up period. At present, endovascular stenting seems to be the method of choice for the treatment of the nutcracker syndrome. (author)

  13. MAG narrow gap welding - an economic way to minimize welding expenses

    International Nuclear Information System (INIS)

    Kast, W.; Scholz, E.; Weyland, F.

    1982-01-01

    The thicker structural components are, the more important it is to take measures to reduce the volume of the weld. The welding process requiring the smallest possible weld section is the so-called narrow gap process. In submerged arc narrow gap welding as well as in MAG narrow gap welding different variants are imaginable, some of them already in practical use. With regard to efficiency and weld quality an optimum variant of the MAG narrow gap welding process is described. It constitutes a two wire system in which two wire electrodes of 1.2 mm diameter are arranged one behind the other. In order to avoid lack of fusion, the wire guides are slightly pointed towards each groove face. Thus, by inclining the two arcs burning one behind the other in the direction of weld progress, it is achieved that two separately solidifying weld pools and two beads per layer are simultaneously formed. Welding parameters are selected in such a way that a heat input of 16-20 kJ/cm and a deposition rate of 11-16 kgs/h are obtained. In spite of this comparatively high deposition rate, good impact values are found both in the weld and HAZ (largely reduced coarse-grain zone) which is due to an optimum weld build-up. With the available welding equipment the process can be applied to structural members having a thickness of 40-400 mm. The width of gap is 13 mm (root section) with a bevel angle of 1 0 . As filler metal, basic flux-cored wires are used which, depending on the base metal to be welded and the required tensile properties, can be of the Mn-, MnMo-, MnCrMo-, MnNi-, or MnNiMo-alloyed types. (orig.)

  14. Advanced Welding Applications

    Science.gov (United States)

    Ding, Robert J.

    2010-01-01

    Some of the applications of advanced welding techniques are shown in this poster presentation. Included are brief explanations of the use on the Ares I and Ares V launch vehicle and on the Space Shuttle Launch vehicle. Also included are microstructural views from four advanced welding techniques: Variable Polarity Plasma Arc (VPPA) weld (fusion), self-reacting friction stir welding (SR-FSW), conventional FSW, and Tube Socket Weld (TSW) on aluminum.

  15. WELDING METHOD

    Science.gov (United States)

    Cornell, A.A.; Dunbar, J.V.; Ruffner, J.H.

    1959-09-29

    A semi-automatic method is described for the weld joining of pipes and fittings which utilizes the inert gasshielded consumable electrode electric arc welding technique, comprising laying down the root pass at a first peripheral velocity and thereafter laying down the filler passes over the root pass necessary to complete the weld by revolving the pipes and fittings at a second peripheral velocity different from the first peripheral velocity, maintaining the welding head in a fixed position as to the specific direction of revolution, while the longitudinal axis of the welding head is disposed angularly in the direction of revolution at amounts between twenty minutas and about four degrees from the first position.

  16. Friction stir welding tool and process for welding dissimilar materials

    Science.gov (United States)

    Hovanski, Yuri; Grant, Glenn J; Jana, Saumyadeep; Mattlin, Karl F

    2013-05-07

    A friction stir welding tool and process for lap welding dissimilar materials are detailed. The invention includes a cutter scribe that penetrates and extrudes a first material of a lap weld stack to a preselected depth and further cuts a second material to provide a beneficial geometry defined by a plurality of mechanically interlocking features. The tool backfills the interlocking features generating a lap weld across the length of the interface between the dissimilar materials that enhances the shear strength of the lap weld.

  17. Influence of diabetes mellitus on the endovascular treatment of abdominal aortic aneurysms.

    NARCIS (Netherlands)

    Leurs, L.J.; Laheij, R.J.F.; Buth, J.

    2005-01-01

    PURPOSE: To investigate the influence of diabetes mellitus on outcome after endovascular abdominal aortic aneurysm (AAA) repair. METHODS: Of 6017 patients enrolled in the EUROSTAR registry after undergoing endovascular AAA repair between May 1994 and December 2003, 731 (12%) had diabetes mellitus

  18. Syllabus in Trade Welding.

    Science.gov (United States)

    New York State Education Dept., Albany. Bureau of Secondary Curriculum Development.

    The syllabus outlines material for a course two academic years in length (minimum two and one-half hours daily experience) leading to entry-level occupational ability in several welding trade areas. Fourteen units covering are welding, gas welding, oxyacetylene welding, cutting, nonfusion processes, inert gas shielded-arc welding, welding cast…

  19. Radial force measurement of endovascular stents: Influence of stent design and diameter.

    Science.gov (United States)

    Matsumoto, Takuya; Matsubara, Yutaka; Aoyagi, Yukihiko; Matsuda, Daisuke; Okadome, Jun; Morisaki, Koichi; Inoue, Kentarou; Tanaka, Shinichi; Ohkusa, Tomoko; Maehara, Yoshihiko

    2016-04-01

    Angioplasty and endovascular stent placement is used in case to rescue the coverage of main branches to supply blood to brain from aortic arch in thoracic endovascular aortic repair. This study assessed mechanical properties, especially differences in radial force, of different endovascular and thoracic stents. We analyzed the radial force of three stent models (Epic, E-Luminexx and SMART) stents using radial force-tester method in single or overlapping conditions. We also analyzed radial force in three thoracic stents using Mylar film testing method: conformable Gore-TAG, Relay, and Valiant Thoracic Stent Graft. Overlapping SMART stents had greater radial force than overlapping Epic or Luminexx stents (P stents was greater than that of all three endovascular stents (P stents, site of deployment, and layer characteristics. In clinical settings, an understanding of the mechanical characteristics, including radial force, is important in choosing a stent for each patient. © The Author(s) 2015.

  20. Endovascular aortic graft infection resulting in retroperitoneal abscess: report of a case

    Directory of Open Access Journals (Sweden)

    Salvatore Di Somma

    2010-06-01

    Full Text Available Infection is a rare complication of aortoiliac endovascular procedures, with an incidence inferior to 0.5%, and it may result in a retroperitoneal abscess potentially evolving to sepsis and gastrointestinal bleeding. In more than 50% of cases endovascular aortoiliac prosthetic grafts infection occur months or years after the procedure. The growing number of endovascular procedures, and as the actually midterm follow up in most cases, septic sequelae will no doubt continue to occur with increased frequency and may represent an emerging problem in the ED for the emergency physician. Endovascular graft infection begins with unspecific clinical manifestations. An high index of suspicion in any patient with an aortic stent graft presenting prolonged or recurrent fever and or abdominal or back pain and a low threshold for obtaining CT scan should increase the clinician’s ability to make a timely diagnosis in the ED setting.

  1. Intestinal infarction: A complication of endovascular therapy

    International Nuclear Information System (INIS)

    England, Andrew; Butterfield, John S.; Sukumar, Sathi; Thompson, David; Roulson, Jo-An; Pritchard, Susan; Ashleigh, Raymond J.

    2007-01-01

    This report presents a rare case of intestinal infarction following endovascular therapy. A female patient who had undergone an internal carotid artery stenting procedure presented suddenly with abdominal pain. Radiological and clinical examinations at the time suggested a picture of intestinal ischaemia, in view of the patient's general conditions and co-existing morbidities surgical intervention was not considered to be an option. The patient died 4 days after the carotid stenting procedure, post-mortem examination revealed infarction of the ileum and caecum. The learning outcomes are if performing endovascular therapy in a patient with diffuse atherosclerotic disease early consideration of intestinal ischaemia should be given to any patient who presents with acute post-procedural abdominal pain

  2. Intestinal infarction: A complication of endovascular therapy

    Energy Technology Data Exchange (ETDEWEB)

    England, Andrew [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom)]. E-mail: andrew.england@smtr.nhs.uk; Butterfield, John S. [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Sukumar, Sathi [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Thompson, David [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Roulson, Jo-An [Department of Histopathology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Pritchard, Susan [Department of Histopathology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Ashleigh, Raymond J. [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom)

    2007-08-15

    This report presents a rare case of intestinal infarction following endovascular therapy. A female patient who had undergone an internal carotid artery stenting procedure presented suddenly with abdominal pain. Radiological and clinical examinations at the time suggested a picture of intestinal ischaemia, in view of the patient's general conditions and co-existing morbidities surgical intervention was not considered to be an option. The patient died 4 days after the carotid stenting procedure, post-mortem examination revealed infarction of the ileum and caecum. The learning outcomes are if performing endovascular therapy in a patient with diffuse atherosclerotic disease early consideration of intestinal ischaemia should be given to any patient who presents with acute post-procedural abdominal pain.

  3. Latest MIG, TIG arc-YAG laser hybrid welding systems for various welding products

    Science.gov (United States)

    Ishide, Takashi; Tsubota, Shuho; Watanabe, Masao

    2003-03-01

    Laser welding is capable of high-efficiency low-strain welding, and so its applications are started to various products. We have also put the high-power YAG laser of up to 10 kW to practical welding use for various products. On the other hand the weakest point of this laser welding is considered to be strict in the welding gap aiming allowance. In order to solve this problem, we have developed hybrid welding of TIG, MIG arc and YAG laser, taking the most advantages of both the laser and arc welding. Since the electrode is coaxial to the optical axis of the YAG laser in this process, it can be applied to welding of various objects. In the coaxial MIG, TIG-YAG welding, in order to make irradiation positions of the YAG laser beams having been guided in a wire or an electrode focused to the same position, the beam transmitted in fibers is separated to form a space between the separated beams, in which the laser is guided. With this method the beam-irradiating area can be brought near or to the arc-generating point. This enables welding of all directions even for the member of a three-dimensional shape. This time we carried out welding for various materials and have made their welding of up to 1 mm or more in welding groove gap possible. We have realized high-speed 1-pass butt welding of 4m/min in welding speed with the laser power of 3 kW for an aluminum alloy plate of approximately 4 mm thick. For a mild steel plate also we have realized butt welding of 1m/min with 5 kW for 6 mm thick. Further, in welding of stainless steel we have shown its welding possibility, by stabilizing the arc with the YAG laser in the welding atmosphere of pure argon, and shown that this welding is effective in high-efficiency welding of various materials. Here we will report the fundamental welding performances and applications to various objects for the coaxial MIG, TIG-YAG welding we have developed.

  4. Ultrasonic testing of austenitic welds and its dependency on the welding process

    International Nuclear Information System (INIS)

    Tabatabaeipour, S.M.; Honarvar, F.

    2009-01-01

    This paper describes the ultrasonic testing of austenitic welds prepared by two different welding processes. The tests were carried out by the ultrasonic Time-of-Flight Diffraction (ToFD) technique. Shielded Metal Arc Welding (SMAW) and Gas Tungsten Arc Welding (GTAW) are the welding processes used for preparing the specimens. Identical artificial defects were implanted in both welds during the welding process. Both specimens were examined by the ToFD technique under similar conditions. Metallographic images were also obtained from the cross sectional plane of both the SMA and GTA welds. These images show that the grain orientation in the two welded specimens are different. D-scan images obtained by the ToFD technique from these welds indicates that inspecting the specimens prepared by the SMAW process is easier than the one made by the GTAW process. The results also show that the D-scan images cannot reveal the small vertical drilled holes implanted in the specimens. (author)

  5. Friction Stir Welding of Tapered Thickness Welds Using an Adjustable Pin Tool

    Science.gov (United States)

    Adams, Glynn; Venable, Richard; Lawless, Kirby

    2003-01-01

    Friction stir welding (FSW) can be used for joining weld lands that vary in thickness along the length of the weld. An adjustable pin tool mechanism can be used to accomplish this in a single-pass, full-penetration weld by providing for precise changes in the pin length relative to the shoulder face during the weld process. The difficulty with this approach is in accurately adjusting the pin length to provide a consistent penetration ligament throughout the weld. The weld technique, control system, and instrumentation must account for mechanical and thermal compliances of the tooling system to conduct tapered welds successfully. In this study, a combination of static and in-situ measurements, as well as active control, is used to locate the pin accurately and maintain the desired penetration ligament. Frictional forces at the pin/shoulder interface were a source of error that affected accurate pin position. A traditional FSW pin tool design that requires a lead angle was used to join butt weld configurations that included both constant thickness and tapered sections. The pitch axis of the tooling was fixed throughout the weld; therefore, the effective lead angle in the tapered sections was restricted to within the tolerances allowed by the pin tool design. The sensitivity of the FSW process to factors such as thickness offset, joint gap, centerline offset, and taper transition offset were also studied. The joint gap and the thickness offset demonstrated the most adverse affects on the weld quality. Two separate tooling configurations were used to conduct tapered thickness welds successfully. The weld configurations included sections in which the thickness decreased along the weld, as well as sections in which the thickness increased along the weld. The data presented here include weld metallography, strength data, and process load data.

  6. The technology and welding joint properties of hybrid laser-tig welding on thick plate

    Science.gov (United States)

    Shenghai, Zhang; Yifu, Shen; Huijuan, Qiu

    2013-06-01

    The technologies of autogenous laser welding and hybrid laser-TIG welding are used on thick plate of high strength lower alloy structural steel 10CrNiMnMoV in this article. The unique advantages of hybrid laser-TIG welding is summarized by comparing and analyzing the process parameters and welding joints of autogenous laser welding laser welding and hybrid laser-TIG welding. With the optimal process parameters of hybrid welding, the good welding joint without visible flaws can be obtained and its mechanical properties are tested according to industry standards. The results show that the hybrid welding technology has certain advantages and possibility in welding thick plates. It can reduce the demands of laser power, and it is significant for lowering the aspect ratio of weld during hybrid welding, so the gas in the molten pool can rise and escape easily while welding thick plates. Therefore, the pores forming tendency decreases. At the same time, hybrid welding enhances welding speed, and optimizes the energy input. The transition and grain size of the microstructure of hybrid welding joint is better and its hardness is higher than base material. Furthermore, its tensile strength and impact toughness is as good as base material. Consequently, the hybrid welding joint can meet the industry needs completely.

  7. Birth Control Patch

    Science.gov (United States)

    ... Health Food & Fitness Diseases & Conditions Infections Drugs & Alcohol School & Jobs Sports Expert Answers (Q&A) Staying Safe Videos for Educators Search English Español Birth Control Patch KidsHealth / For Teens / Birth Control Patch What's ...

  8. Effects of post weld heat treatment and weld overlay on the residual stress and mechanical properties in dissimilar metal weld

    International Nuclear Information System (INIS)

    Campos, Wagner R.C.; Ribeiro, Vladimir S.; Vilela, Alisson H.F.; Almeida, Camila R.O.; Rabello, Emerson G.

    2017-01-01

    The object of this work is a dissimilar metal weld (DMW) pipe joint between carbon steel (A-106 Gr B) and stainless steel (A-312 TP316L) pipes and filler metals of Nickel alloy (82/182), which find wide application in the field of chemical, oil, petroleum industries, fossil fuel and nuclear power plant. A lot of the failures that have occurred in dissimilar metal welded are affected greatly by residual stresses. Residual stress is often a cause of premature failure of critical components under normal operation of welded components. Several methods have been tested and developed for removing the tensile residual stresses. The aim of the methods is to reduce the tensile stress state or to create compressive stresses at a predefined area, such as the inner surface of a welded pipe joint. Post weld heat treatment (PWHT) and weld overlay (WOL) are two of the residual stress mitigation methods which reduce the tensile residual stress, create compressive stresses and arrest crack initiation and crack growth. The technique used to substantially minimized or eliminated this failure development in the root weld is the post weld heat treatments (stress relief heat treatment) or the weld overlay. In this work was studied the effectiveness in reducing internal residual stress in dissimilar metal welded pipe joints subjected to post weld heat treatment and weld overlay, measurement by hole-drilling strain-gage method of stress relaxation. Also held was mechanical characterization of the welded pipe joint itself. (author)

  9. Effects of post weld heat treatment and weld overlay on the residual stress and mechanical properties in dissimilar metal weld

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Wagner R.C.; Ribeiro, Vladimir S.; Vilela, Alisson H.F.; Almeida, Camila R.O.; Rabello, Emerson G., E-mail: wrcc@cdtn.br, E-mail: camilarezende.cr@gmail.com, E-mail: egr@cdtn.br, E-mail: vladimirsoler@hotmail.com, E-mail: ahfv02@outlook.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    The object of this work is a dissimilar metal weld (DMW) pipe joint between carbon steel (A-106 Gr B) and stainless steel (A-312 TP316L) pipes and filler metals of Nickel alloy (82/182), which find wide application in the field of chemical, oil, petroleum industries, fossil fuel and nuclear power plant. A lot of the failures that have occurred in dissimilar metal welded are affected greatly by residual stresses. Residual stress is often a cause of premature failure of critical components under normal operation of welded components. Several methods have been tested and developed for removing the tensile residual stresses. The aim of the methods is to reduce the tensile stress state or to create compressive stresses at a predefined area, such as the inner surface of a welded pipe joint. Post weld heat treatment (PWHT) and weld overlay (WOL) are two of the residual stress mitigation methods which reduce the tensile residual stress, create compressive stresses and arrest crack initiation and crack growth. The technique used to substantially minimized or eliminated this failure development in the root weld is the post weld heat treatments (stress relief heat treatment) or the weld overlay. In this work was studied the effectiveness in reducing internal residual stress in dissimilar metal welded pipe joints subjected to post weld heat treatment and weld overlay, measurement by hole-drilling strain-gage method of stress relaxation. Also held was mechanical characterization of the welded pipe joint itself. (author)

  10. Endovascular treatment of intracranial venous sinus thrombosis

    International Nuclear Information System (INIS)

    Xu Shubin; Liang Zhihui; Cui Jinguo; Tian Huiqin; Li Liang; Chen Feng

    2009-01-01

    Objective: To evaluate the clinical efficacy and safety of endovascular treatment for intracranial venous sinus thrombosis. Methods: Ten patients with intracranial venous sinus thrombosis, confirmed by CT, MRI, MRV and / or DSA and encountered during the period of Aug. 2005-Aug. 2007, were treated with endovascular management after they failed to respond to anticoagulant therapy. Of ten patients, intravenous thrombolysis and mechanical thrombus maceration were carried out in 6, while intravenous thrombolysis, mechanical thrombus maceration together with intra-arterial thrombolysis were employed in 4. After the treatment, the anticoagulant therapy continued for 6 months. The patients were followed up for 12-29 months (mean 21 months). Results: After the treatment, the clinical symptoms and signs were completely or partially relieved in eight patients, including disappearance of headache (n=6) and relive of headache (n=2). No obvious improvement was found in one patient and linguistic function disturbance was seen in the remaining one. Lumbar puncture showed that the cerebrospinal fluid pressure returned to normal in all patients. Neither recurrence of thrombosis nor new symptom of neuralgic dysfunction was observed. No procedure-related intracranial or systemic hemorrhagic complications occurred both during and after the operation. Conclusion: Endovascular treatment is an effective and safe procedure for the potentially catastrophic intracranial venous thrombosis. (authors)

  11. Complications of endovascular treatment of cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Orrù, Emanuele, E-mail: surgeon.ema@gmail.com [Neuroradiology Department, Padua University Hospital, Via Giustiniani 2, Padua 35128 (Italy); Roccatagliata, Luca, E-mail: lroccatagliata@neurologia.unige.it [Neuroradiology Department, IRCCS San Martino University Hospital and IST, Largo Rosanna Benzi 10, Genoa 16132 (Italy); Department of Health Sciences (DISSAL), University of Genoa (Italy); Cester, Giacomo, E-mail: giacomo.cester@sanita.padova.it [Neuroradiology Department, Padua University Hospital, Via Giustiniani 2, Padua 35128 (Italy); Causin, Francesco, E-mail: francesco.causin@sanita.padova.it [Neuroradiology Department, Padua University Hospital, Via Giustiniani 2, Padua 35128 (Italy); Castellan, Lucio, E-mail: lucio.castellan@hsanmartino.it [Neuroradiology Department, IRCCS San Martino University Hospital and IST, Largo Rosanna Benzi 10, Genoa 16132 (Italy)

    2013-10-01

    The number of neuroendovascular treatments of both ruptured and unruptured aneurysms has increased substantially in the last two decades. Complications of endovascular treatments of cerebral aneurysms are rare but can potentially lead to acute worsening of the neurological status, to new neurological deficits or death. Some of the possible complications, such as vascular access site complications or systemic side effects associated with contrast medium (e.g. contrast medium allergy, contrast induced nephropathy) can also be encountered in diagnostic angiography. The most common complications of endovascular treatment of cerebral aneurysms are related to acute thromboembolic events and perforation of the aneurysm. Overall, the reported rate of thromboembolic complications ranges between 4.7% and 12.5% while the rate of intraprocedural rupture of cerebral aneurysms is about 0.7% in patients with unruptured aneurysms and about 4.1% in patients with previously ruptured aneurysms. Thromboembolic and hemorrhagic complications may occur during different phases of endovascular procedures and are related to different technical, clinical and anatomic reasons. A thorough knowledge of the different aspects of these complications can reduce the risk of their occurrence and minimize their clinical sequelae. A deep understanding of complications and of their management is thus part of the best standard of care.

  12. Endovascular stent-graft exclusion of aortic dissection combined with renal failure

    International Nuclear Information System (INIS)

    Feng Xiang; Jing Zaiping; Yuan Weijie; Bao Junmin; Zhao Zhiqing; Zhao Jun; Lu Qingsheng

    2003-01-01

    Objective: To investigate the indications and peri-operative management of endovascular graft exclusion of aortic dissection combined with renal failure. Methods: Endovascular graft exclusion for Stanford B type thoracic aortic dissection had been preformed on 136 patients including two complicated with renal failure. Hemodialysis was preformed before operation with the fluid infusion controlled during the operation and bed-side hemodialysis after the operation for the latter. Results: All the 2 cases with renal failure complication were successfully carried out, and the peri-operative metabolism and circulation were kept on smoothly. Conclusions: Under good peri-operative management, patients having aortic dissection combined with renal failure could receive the endovascular graft exclusion of aortic dissection safely

  13. On use of weld zone temperatures for online monitoring of weld quality in friction stir welding of naturally aged aluminium alloys

    International Nuclear Information System (INIS)

    Imam, Murshid; Biswas, Kajal; Racherla, Vikranth

    2013-01-01

    Highlights: • FSWs for 6063-T4 AA are done at different process parameters and sheet thicknesses. • Weld nugget zone and heat affected zone temperatures are monitored for each case. • Microstructural and mechanical characterisation of welds is done in all cases. • Weld ductility is found to be particularly sensitive to weld zone temperatures. • Strong correlation is found between WNZ and HAZ temperatures and weld properties. - Abstract: 6063-T4 aluminium alloy sheets of 3 and 6 mm thicknesses were friction stir butt welded using a square tool pin at a wide range of tool rotational speeds. Properties of obtained welds were characterised using tensile tests, optical micrographs, X-ray diffraction, and transmission electron microscopy. Shape, size, and distribution of precipitates in weld zones, and strength and ductility of welds were seen to directly correlate with peak temperatures in weld nugget and heat affected zones, independent of sheet thickness. In addition, fluctuations in measured temperature profiles, for 3 mm sheets, were seen to correlate with an increase in scatter of weld nugget zone properties for 3 mm sheets. Optimal weld strength and ductility were obtained for peak weld nugget zone temperatures of around 450 °C and corresponding peak heat affected zone temperatures of around 360–380 °C. Results obtained suggest that, at least for naturally aged aluminium alloys, nature of temperature evolution and magnitudes of peak temperatures in weld nugget and heat affected zones provide information on uniformity of properties in weld zones, overaging of heat affected zones, and formation of tunnel defects from improper material mixing at low weld zone temperatures

  14. Measuring weld heat to evaluate weld integrity

    Energy Technology Data Exchange (ETDEWEB)

    Schauder, V., E-mail: schauder@hks-prozesstechnik.de [HKS-Prozesstechnik GmbH, Halle (Germany)

    2015-11-15

    Eddy current and ultrasonic testing are suitable for tube and pipe mills and have been used for weld seam flaw detection for decades, but a new process, thermography, is an alternative. By measuring the heat signature of the weld seam as it cools, it provides information about weld integrity at and below the surface. The thermal processes used to join metals, such as plasma, induction, laser, and gas tungsten arc welding (GTAW), have improved since they were developed, and they get better with each passing year. However, no industrial process is perfect, so companies that conduct research in flaw detection likewise continue to develop and improve the technologies used to verify weld integrity: ultrasonic testing (UT), eddy current testing (ET), hydrostatic, X-ray, magnetic particle, and liquid penetrant are among the most common. Two of these are used for verifying the integrity of the continuous welds such as those used on pipe and tube mills: UT and ET. Each uses a transmitter to send waves of ultrasonic energy or electrical current through the material and a receiver (probe) to detect disturbances in the flow. The two processes often are combined to capitalize on the strengths of each. While ET is good at detecting flaws at or near the surface, UT penetrates the material, detecting subsurface flaws. One drawback is that sound waves and electrical current waves have a specific direction of travel, or an alignment. A linear defect that runs parallel to the direction of travel of the ultrasonic sound wave or a flaw that is parallel to the coil winding direction of the ET probe can go undetected. A second drawback is that they don't detect cold welds. An alternative process, thermography, works in a different fashion: It monitors the heat of the material as the weld cools. Although it measures the heat at the surface, the heat signature provides clues about cooling activity deep in the material, resulting in a thorough assessment of the weld's integrity It

  15. The effect of post-welding conditions in friction stir welds: From weld simulation to Ductile Failure

    DEFF Research Database (Denmark)

    Hattel, Jesper Henri; Nielsen, Kim Lau; Tutum, Cem Celal

    2012-01-01

    software ANSYS, a thermo-mechanical model is employed to predict the thermally induced stresses and strains during welding, while an in-house finite element code is used to study the plastic flow localization and failure in a subsequent structural analysis. The coupling between the two models is made......The post-welding stress state, strain history and material conditions of friction stir welded joints are often strongly idealized when used in subsequent modeling analyses, typically by neglecting one or more of the features above. But, it is obvious that the conditions after welding do influence......, showed the largest influence of the post-welding conditions, even though significant relaxation of the residual stress state was predicted....

  16. Nitrogen And Oxygen Amount In Weld After Welding With Micro-Jet Cooling

    Directory of Open Access Journals (Sweden)

    Węgrzyn T.

    2015-06-01

    Full Text Available Micro-jet cooling after welding was tested only for MIG welding process with argon, helium and nitrogen as a shielded gases. A paper presents a piece of information about nitrogen and oxygen in weld after micro-jet cooling. There are put down information about gases that could be chosen both for MIG/MAG welding and for micro-jet process. There were given main information about influence of various micro-jet gases on metallographic structure of steel welds. Mechanical properties of weld was presented in terms of nitrogen and oxygen amount in WMD (weld metal deposit.

  17. A study of weld quality in ultrasonic spot welding of similar and dissimilar metals

    International Nuclear Information System (INIS)

    Al-Sarraf, Z; Lucas, M

    2012-01-01

    Several difficulties are faced in joining thinner sheets of similar and dissimilar materials from fusion welding processes such as resistance welding and laser welding. Ultrasonic metal welding overcomes many of these difficulties by using high frequency vibration and applied pressure to create a solid-state weld. Ultrasonic metal welding is an effective technique in joining small components, such as in wire bonding, but is also capable of joining thicker sheet, depending on the control of welding conditions. This study presents the design, characterisation and test of a lateral-drive ultrasonic metal welding device. The ultrasonic welding horn is modelled using finite element analysis and its vibration behaviour is characterised experimentally to ensure ultrasonic energy is delivered to the weld coupon. The welding stack and fixtures are then designed and mounted on a test machine to allow a series of experiments to be conducted for various welding and ultrasonic parameters. Weld strength is subsequently analysed using tensile-shear tests. Control of the vibration amplitude profile through the weld cycle is used to enhance weld strength and quality, providing an opportunity to reduce part marking. Optical microscopic examination and scanning electron microscopy (SEM) were employed to investigate the weld quality. The results show how the weld quality is particularly sensitive to the combination of clamping force and vibration amplitude of the welding tip.

  18. Headache and endovascular procedures.

    Science.gov (United States)

    de Biase, Stefano; Longoni, Marco; Gigli, Gian Luigi; Agostoni, Elio

    2017-05-01

    The International Classification of Headache Disorders (ICHD-3 beta) includes headache attributed to intracranial endovascular procedures (EVPs). The aim of this review is to describe the clinical and pathophysiological aspects of headache related to vascular lesions and EVPs. Current studies regarding this issue are contradictory, although generally favouring headache improvement after EVPs. Further large studies are needed to adequately assess the effect of EVPs on headache.

  19. Welding and cutting

    International Nuclear Information System (INIS)

    Drews, P.; Schulze Frielinghaus, W.

    1978-01-01

    This is a survey, with 198 literature references, of the papers published in the fields of welding and cutting within the last three years. The subjects dealt with are: weldability of the materials - Welding methods - Thermal cutting - Shaping and calculation of welded joints - Environmental protection in welding and cutting. (orig.) [de

  20. Simplified welding distortion analysis for fillet welding using composite shell elements

    Directory of Open Access Journals (Sweden)

    Mingyu Kim

    2015-05-01

    Full Text Available This paper presents the simplified welding distortion analysis method to predict the welding deformation of both plate and stiffener in fillet welds. Currently, the methods based on equivalent thermal strain like Strain as Direct Boundary (SDB has been widely used due to effective prediction of welding deformation. Regarding the fillet welding, however, those methods cannot represent deformation of both members at once since the temperature degree of freedom is shared at the intersection nodes in both members. In this paper, we propose new approach to simulate deformation of both members. The method can simulate fillet weld deformations by employing composite shell element and using different thermal expansion coefficients according to thickness direction with fixed temperature at intersection nodes. For verification purpose, we compare of result from experiments, 3D thermo elastic plastic analysis, SDB method and proposed method. Compared of experiments results, the proposed method can effectively predict welding deformation for fillet welds.

  1. Welding Technician

    Science.gov (United States)

    Smith, Ken

    2009-01-01

    About 95% of all manufactured goods in this country are welded or joined in some way. These welded products range in nature from bicycle handlebars and skyscrapers to bridges and race cars. The author discusses what students need to know about careers for welding technicians--wages, responsibilities, skills needed, career advancement…

  2. [Actual review of diagnostics and endovascular therapy of intracranial arterial stenoses].

    Science.gov (United States)

    Gizewski, E R; Weber, R; Forsting, M

    2011-02-01

    Approximately 6 - 50% of all ischemic strokes are caused by intracranial arterial stenosis (IAS). Despite medical prevention, patients with symptomatic IAS have a high annual risk for recurrent ischemic stroke of about 12%, and up to 19% in the case of high-grade IAS (≥ 70%). Digital subtraction angiography remains the gold standard for the diagnosis and grading of IAS. However, noninvasive imaging techniques including CT angiography, MR angiography, or transcranial Doppler and duplex ultrasound examinations are used in the clinical routine to provide additional information about the brain structure and hemodynamic. However, for technical reasons, the grading of stenoses is sometimes difficult and inaccurate. To date, aspirin is recommended as the treatment of choice in the prevention of recurrent ischemic stroke in patients with IAS. IAS patients who suffer a recurrent ischemic stroke or transient ischemic attack while taking aspirin can be treated with endovascular stenting or angioplasty in specialized centers. The periprocedural complication rate of these endovascular techniques is about 2 - 7% at experienced neuro-interventional centers. The rate of re-stenosis is reported between 10 and 40% depending on patient age and stenosis location. Further randomized studies comparing medical secondary prevention and endovascular therapy are currently being performed. With regard to the improvement of endovascular methods and lower complication rates, the indication for endovascular therapy in IAS could be broadened especially for stenosis in the posterior circulation. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Introduction to Welding.

    Science.gov (United States)

    Fortney, Clarence; Gregory, Mike

    This curriculum guide provides six units of instruction on basic welding. Addressed in the individual units of instruction are the following topics: employment opportunities for welders, welding safety and first aid, welding tools and equipment, basic metals and metallurgy, basic math and measuring, and procedures for applying for a welding job.…

  4. Orbital welding technique

    International Nuclear Information System (INIS)

    Hoeschen, W.

    2003-01-01

    The TIG (Tungsten-inert gas) orbital welding technique is applied in all areas of pipe welding. The process is mainly used for austenitic and ferritic materials but also for materials like aluminium, nickel, and titanium alloys are commonly welded according to this technique. Thin-walled as well as thick-walled pipes are welded economically. The application of orbital welding is of particular interest in the area of maintenance of thick-walled pipes that is described in this article. (orig.) [de

  5. Granisetron Transdermal Patch

    Science.gov (United States)

    Granisetron transdermal patches are used to prevent nausea and vomiting caused by chemotherapy. Granisetron is in a class of medications called 5HT3 ... Granisetron transdermal comes as a patch to apply to the skin. It is usually applied 24 to ...

  6. Non-standard patch test

    Directory of Open Access Journals (Sweden)

    Astri Adelia

    2018-06-01

    Full Text Available In managing contact dermatitis, identification of the causative agent is essential to prevent recurrent complaints. Patch test is the gold standard to identify the causative agent. Nowadays, there are many patch test standard materials available in the market, but do not include all the materials that potentially cause contact dermatitis. Patch test using patient’s own products or later we refer to as non-standard materials, is very helpful in identifying the causative agents of contact dermatitis. Guidance is needed in producing non-standard patch test materials in order to avoid test results discrepancy.

  7. Welding stresses

    International Nuclear Information System (INIS)

    Poirier, J.; Barbe, B.; Jolly, N.

    1976-01-01

    The aim is to show how internal stresses are generated and to fix the orders of magnitude. A realistic case, the vertical welding of thick plates free to move one against the other, is described and the deformations and stresses are analyzed. The mathematical model UEDA, which accounts for the elastic modulus, the yield strength and the expansion coefficient of the metal with temperature, is presented. The hypotheses and results given apply only to the instantaneous welding of a welded plate and to a plate welded by a moving electrode [fr

  8. Reduction of Biomechanical and Welding Fume Exposures in Stud Welding.

    Science.gov (United States)

    Fethke, Nathan B; Peters, Thomas M; Leonard, Stephanie; Metwali, Mahmoud; Mudunkotuwa, Imali A

    2016-04-01

    The welding of shear stud connectors to structural steel in construction requires a prolonged stooped posture that exposes ironworkers to biomechanical and welding fume hazards. In this study, biomechanical and welding fume exposures during stud welding using conventional methods were compared to exposures associated with use of a prototype system that allowed participants to weld from an upright position. The effect of base material (i.e. bare structural beam versus galvanized decking) on welding fume concentration (particle number and mass), particle size distribution, and particle composition was also explored. Thirty participants completed a series of stud welding simulations in a local apprenticeship training facility. Use of the upright system was associated with substantial reductions in trunk inclination and the activity levels of several muscle groups. Inhalable mass concentrations of welding fume (averaged over ~18 min) when using conventional methods were high (18.2 mg m(-3) for bare beam; 65.7 mg m(-3) for through deck), with estimated mass concentrations of iron (7.8 mg m(-3) for bare beam; 15.8 mg m(-3) for through deck), zinc (0.2 mg m(-3) for bare beam; 15.8 mg m(-3) for through deck), and manganese (0.9 mg m(-3) for bare beam; 1.5 mg m(-3) for through deck) often exceeding the American Conference of Governmental Industrial Hygienists Threshold Limit Values (TLVs). Number and mass concentrations were substantially reduced when using the upright system, although the total inhalable mass concentration remained above the TLV when welding through decking. The average diameters of the welding fume particles for both bare beam (31±17 nm) through deck conditions (34±34 nm) and the chemical composition of the particles indicated the presence of metallic nanoparticles. Stud welding exposes ironworkers to potentially high levels of biomechanical loading (primarily to the low back) and welding fume. The upright system used in this study improved exposure

  9. Detection of damage in welded structure using experimental modal data

    Energy Technology Data Exchange (ETDEWEB)

    Abu Husain, N [Transportation Research Alliance, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor (Malaysia); Ouyang, H, E-mail: nurul@fkm.utm.my, E-mail: h.ouyang@liv.ac.uk [Department of Engineering, Harrison-Hughes Building, University of Liverpool, Brownlow Hill, Liverpool L69 3GH (United Kingdom)

    2011-07-19

    A typical automotive structure could contain thousands of spot weld joints that contribute significantly to the vehicle's structural stiffness and dynamic characteristics. However, some of these joints may be imperfect or even absent during the manufacturing process and they are also highly susceptible to damage due to operational and environmental conditions during the vehicle lifetime. Therefore, early detection and estimation of damage are important so necessary actions can be taken to avoid further problems. Changes in physical parameters due to existence of damage in a structure often leads to alteration of vibration modes; thus demonstrating the dependency between the vibration characteristics and the physical properties of structures. A sensitivity-based model updating method, performed using a combination of MATLAB and NASTRAN, has been selected for the purpose of this work. The updating procedure is regarded as parameter identification which aims to bring the numerical prediction to be as closely as possible to the measured natural frequencies and mode shapes data of the damaged structure in order to identify the damage parameters (characterised by the reductions in the Young's modulus of the weld patches to indicate the loss of material/stiffness at the damage region).

  10. Endovascular retrieval of a CardioMEMS heart failure system

    Directory of Open Access Journals (Sweden)

    Arun Reghunathan, MD

    2018-04-01

    Full Text Available As the creation and utilization of new implantable devices increases, so does the need for interventionalists to devise unique retrieval mechanisms. This report describes the first endovascular retrieval of a CardioMEMS heart failure monitoring device. A 20-mm gooseneck snare was utilized in conjunction with a 9-French sheath and Envoy catheter for retrieval. The patient suffered no immediate postprocedural complications but died 5 days after the procedure from multiorgan failure secondary to sepsis. Keywords: CardioMEMS heart failure system, Endovascular retrieval

  11. Experiencia en el manejo endovascular para el tratamiento de la aorta torácica Experience in endovascular management for thoracic aorta treatment

    Directory of Open Access Journals (Sweden)

    Juan G Barrera

    2007-12-01

    Full Text Available Antecedentes: el tratamiento endovascular ofrece la posibilidad de cubrir el origen de la disección y evitar que progrese hasta aneurisma de la aorta, y con ello demuestra una reducción en la mortalidad hasta del 16%. Objetivo: evaluar los resultados quirúrgicos en términos de morbi-mortalidad de los pacientes sometidos a manejo endovascular de las lesiones de la aorta torácica en la Fundación Cardiovascular de Colombia desde 2003 hasta 2005. Diseño-método: estudio longitudinal tipo descriptivo retrospectivo, en el que se evaluaron las historias clínicas de todos los pacientes sometidos a manejo endovascular de patología toracoabdominal; en éste sólo se incluyeron los pacientes con procedimientos de la aorta torácica, desde 2003 hasta 2005. El análisis de los datos se realizó en Stata/SE 8,0. Resultados: se realizaron procedimientos de aorta torácica en 16 pacientes. El 75% de los pacientes eran hombres con edad promedio de 55,9 ± 12,6 años. El 87,5% (14 pacientes presentaban disección aórtica tipo A o B; un paciente transección traumática de la aorta y un paciente aneurisma de aorta torácica descendente. Las disecciones agudas se presentaron en 78,6% (11 pacientes y las crónicas en 21,4% (3 pacientes. El promedio de endoprótesis usadas fue de 2,8 ± 1. La estancia en la unidad de cuidados intensivos fue de 3 ± 2,7 días. El 81,3% de los pacientes no presentaron complicaciones mayores. La mortalidad fue del 18,7% (3 pacientes. A todos se les realizó control post-operatorio con tomografía axial computarizada, con evolución satisfactoria. Conclusión: de acuerdo con los reportes de la literatura con mayor casuística, se considera que el manejo endovascular para el tratamiento de la disección, aneurisma o trauma aórtico es un procedimiento confiable que disminuye la morbi-mortalidad.Antecedents: endovascular treatment has the possibility of covering the dissection origin and to avoid its progression to aortic

  12. High-Speed Friction-Stir Welding to Enable Aluminum Tailor-Welded Blanks

    Science.gov (United States)

    Hovanski, Yuri; Upadhyay, Piyush; Carsley, John; Luzanski, Tom; Carlson, Blair; Eisenmenger, Mark; Soulami, Ayoub; Marshall, Dustin; Landino, Brandon; Hartfield-Wunsch, Susan

    2015-05-01

    Current welding technologies for production of aluminum tailor-welded blanks (TWBs) are utilized in low-volume and niche applications, and they have yet to be scaled for the high-volume vehicle market. This study targeted further weight reduction, part reduction, and cost savings by enabling tailor-welded blank technology for aluminum alloys at high volumes. While friction-stir welding (FSW) has been traditionally applied at linear velocities less than 1 m/min, high-volume production applications demand the process be extended to higher velocities more amenable to cost-sensitive production environments. Unfortunately, weld parameters and performance developed and characterized at low-to-moderate welding velocities do not directly translate to high-speed linear FSW. Therefore, to facilitate production of high-volume aluminum FSW components, parameters were developed with a minimum welding velocity of 3 m/min. With an emphasis on weld quality, welded blanks were evaluated for postweld formability using a combination of numerical and experimental methods. An evaluation across scales was ultimately validated by stamping full-size production door inner panels made from dissimilar thickness aluminum TWBs, which provided validation of the numerical and experimental analysis of laboratory-scale tests.

  13. Estimation of weld nugget temperature by thermography method in resistance projection welding process

    International Nuclear Information System (INIS)

    Setty, D.S.; Rameswara Roa, A.; Hemantha Rao, G.V.S.; Jaya Raj, R.N.

    2008-01-01

    In the Pressurized Heavy Water Reactor (PHWR) fuel manufacturing, zirconium alloy appendages like spacer and bearing pads are welded to the thin wall zirconium alloy fuel tubes by using resistance projection welding process. Out of many joining processes available, resistance-welding process is reliable, environment friendly and best suitable for mass production applications. In the fuel assembly, spacer pads are used to get the required inter-element spacing and Bearing pads are used to get the required load-bearing surface for the fuel assembly. Performance of the fuel assembly in the reactor is greatly influenced by these weld joint's quality. Phase transformation from α to β phase is not acceptable while welding these tiny appendages. At present only destructive metallography test is available for this purpose. This can also be achieved by measuring weld nugget temperature where in the phase transformation temperature for zirconium alloy material is 853 o C. The temperature distribution during resistance welding of tiny parts cannot be measured by conventional methods due to very small space and short weld times involved in the process. Shear strength, dimensional accuracy and weld microstructures are some of the key parameters used to measure the quality of appendage weld joints. Weld parameters were optimized with the help of industrial experimentation methodology. Individual projection welding by split electrode concept, and during welding on empty tube firm support is achieved on inner side of the tube by using expandable pneumatic mandrel. In the present paper, an attempt was made to measure the weld nugget temperature by thermography technique and is correlated with standard microstructures of zirconium alloy material. The temperature profiles in the welding process are presented for different welding conditions. This technique has helped in measuring the weld nugget temperature more accurately. It was observed that in the present appendage welding

  14. Fatal late multiple emboli after endovascular treatment of abdominal aortic aneurysm. Case report

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Sandermann, Jes; Bruun-Petersen, J

    1998-01-01

    The short term experience of endovascular treatment of abdominal aortic aneurysms (AAA) seems promising but long term randomised data are lacking. Consequently, cases treated by endovascular procedures need to be closely followed for potential risks and benefits....

  15. Influence of Loading Direction and Weld Reinforcement on Fatigue Performance of TIG Weld Seam

    Directory of Open Access Journals (Sweden)

    HUI Li

    2018-02-01

    Full Text Available The influence of loading direction and weld reinforcement on fatigue performance of TC2 titanium alloy TIG weld seam was investigated via fatigue experiments and SEM fracture observation. The results show that the fatigue life of retaining weld reinforcement specimens is lower than that of removing one in the same weld direction. The fatigue life of oblique weld specimens is higher than that of straight one with the same weld reinforcement treatment. The initiation of removing weld reinforcement specimens' fatigue crack sources is in the hole defect, but the weld reinforcement specimen initiate at the weld toes. During the early stage of fatigue crack propagation, the cracks all grow inside the weld seam metal with obvious fatigue striation. And the fatigue cracks of oblique weld specimens pass through the weld seam into the base with a typical toughness fatigue striation during the last stage of fatigue crack propagation. The dimple of straight weld specimens is little and shallow in the final fracture zone. The oblique weld specimens broke in the base metal area, and the dimple is dense.

  16. Nitrogen And Oxygen Amount In Weld After Welding With Micro-Jet Cooling

    OpenAIRE

    Węgrzyn T.; Piwnik J.

    2015-01-01

    Micro-jet cooling after welding was tested only for MIG welding process with argon, helium and nitrogen as a shielded gases. A paper presents a piece of information about nitrogen and oxygen in weld after micro-jet cooling. There are put down information about gases that could be chosen both for MIG/MAG welding and for micro-jet process. There were given main information about influence of various micro-jet gases on metallographic structure of steel welds. Mechanical properties of weld was pr...

  17. Transatlantic Multispecialty Consensus on Fundamental Endovascular Skills: Results of a Delphi Consensus Study.

    Science.gov (United States)

    Maertens, H; Aggarwal, R; Macdonald, S; Vermassen, F; Van Herzeele, I

    2016-01-01

    The aim of this study was to establish a consensus on Fundamental Endovascular Skills (FES) for educational purposes and development of training curricula for endovascular procedures. The term "Fundamental Endovascular Skills" is widely used; however, the current literature does not explicitly describe what skills are included in this concept. Endovascular interventions are performed by several specialties that may have opposing perspectives on these skills. A two round Delphi questionnaire approach was used. Experts from interventional cardiology, interventional radiology, and vascular surgery from the United States and Europe were invited to participate. An electronic questionnaire was generated by endovascular therapists with an appropriate educational background but who would not participate in subsequent rounds. The questionnaire consisted of 50 statements describing knowledge, technical, and behavioral skills during endovascular procedures. Experts received the questionnaires by email. They were asked to rate the importance of each skill on a Likert scale from 1 to 5. A statement was considered fundamental when more than 90% of the experts rated it 4 or 5 out of 5. Twenty-three of 53 experts invited agreed to participate: six interventional radiologists (2 USA, 4 Europe), 10 vascular surgeons (4 USA, 6 Europe), and seven interventional cardiologists (4 USA, 3 Europe). There was a 100% response rate in the first round and 87% in the second round. Results showed excellent consensus among responders (Cronbach's alpha = .95 first round; .93 second round). Ninety percent of all proposed skills were considered fundamental. The most critical skills were determined. A transatlantic multispecialty consensus was achieved about the content of "FES" among interventional radiologists, interventional cardiologists, and vascular surgeons from Europe and the United States. These results can serve as directive principles for developing endovascular training curricula

  18. Influence of weld structure on cross-weld creep behavior in P23 steel

    Energy Technology Data Exchange (ETDEWEB)

    Allen, D.J.; Degnan, C.C. [E.ON Engineering (United Kingdom); Brett, S.J. [RWE npower (United Kingdom); Buchanan, L.W. [Doosan Babcock (United Kingdom)

    2010-07-01

    A thick section pipe weld in low alloy steel P23 has been characterised by cross-weld creep rupture testing at a range of stresses, together with all-weld-metal and parent material testing, under the auspices of the UK High Temperature Power Plant Forum. The results generally show that the weld metal can be weak when tested in the transverse (cross-weld) orientation, and can fail with limited overall ductility by cracking in the zone of refined weld metal beneath the fusion boundary of the superposed weld bead. However, one specimen showed a much superior performance, which could be understood in terms of its locally more creep resistant weld macrostructure. The implications for P23 performance and weld manufacture are discussed. (orig.)

  19. Welded joints integrity analysis and optimization for fiber laser welding of dissimilar materials

    Science.gov (United States)

    Ai, Yuewei; Shao, Xinyu; Jiang, Ping; Li, Peigen; Liu, Yang; Liu, Wei

    2016-11-01

    Dissimilar materials welded joints provide many advantages in power, automotive, chemical, and spacecraft industries. The weld bead integrity which is determined by process parameters plays a significant role in the welding quality during the fiber laser welding (FLW) of dissimilar materials. In this paper, an optimization method by taking the integrity of the weld bead and weld area into consideration is proposed for FLW of dissimilar materials, the low carbon steel and stainless steel. The relationships between the weld bead integrity and process parameters are developed by the genetic algorithm optimized back propagation neural network (GA-BPNN). The particle swarm optimization (PSO) algorithm is taken for optimizing the predicted outputs from GA-BPNN for the objective. Through the optimization process, the desired weld bead with good integrity and minimum weld area are obtained and the corresponding microstructure and microhardness are excellent. The mechanical properties of the optimized joints are greatly improved compared with that of the un-optimized welded joints. Moreover, the effects of significant factors are analyzed based on the statistical approach and the laser power (LP) is identified as the most significant factor on the weld bead integrity and weld area. The results indicate that the proposed method is effective for improving the reliability and stability of welded joints in the practical production.

  20. Endovascular repair as a sole treatment in multiple aneurysms in patient with SLE

    International Nuclear Information System (INIS)

    Dineva, S.; Al-Amin, M.; Demetriou, S.; Tsetis, D.

    2013-01-01

    Full text: Introduction: Most aneurysms are local manifestations of systemic disease. For patients over 65 years the incidence of aneurysm of the abdominal aorta (AAA) is approximately 5-6% in men and 1-2 % for women. The presence of both the AAA and aneurysms in other location is even rarer, and this percentage is likely increase further in patients with systemic lupus erythematosus (SLE). What you will learn: We present a rare clinical case of endovascular treatment of multifocal aneurysm including post catheterization pseudoaneurysm. The patient is a 73 years old woman with a history of SLE and age-related comorbidity. Originally an endovascular treatment of aneurysms of the abdominal aorta and right common iliac artery was used. Two years later a successfully endovascular treatment of aneurysm of the right renal artery was conducted, which however is complicated by the formation of a pseudoaneurysm in access through the left femoral artery. The late one is again treated endovascular by placement of a covered stent after failure of percutaneous injection of 1000 UI thrombin. Discussion: Adult patients with a long history of SLE are unsuitable candidates for surgical treatment of aneurysmal disease, especially in its multifocal form. In our case we have taken multistep successful endovascular procedures, including technically hard placing of the stent at the site of the right renal aneurysms, and post catheterization pseudoaneurysm. Conclusion: Multifocal aneurysmal vascular changes due to macroangiopathia in SLE can be treated alone by endovascular means in multi-stages procedures

  1. Endovascular Mechanical Thrombectomy in Basilar Artery Occlusion: Initial Experience

    Science.gov (United States)

    Park, Bum-Soo; Kwon, Hyon-Jo; Choi, Seung-Won; Kim, Seon-Hwan; Koh, Hyeon-Song; Youm, Jin-Young; Song, Shi-Hun

    2013-01-01

    Objective This study was conducted to assess the efficacy and safety of endovascular mechanical thrombectomy (EMT) for patients diagnosed with basilar artery (BA) occlusion. Materials and Methods We retrospectively analyzed clinical and imaging data of 16 patients diagnosed with BA occlusion who were treated with endovascular intervention from July 2012 to February 2013. Direct suction using the Penumbra system and thrombus retrieval by the Solitaire stent were the main endovascular techniques used to restore BA flow. The outcomes were evaluated based on rate of angiographic recanalization, rate of improvement of National Institutes of Health Stroke Scale (NIHSS) score, rate of modified Rankin Scale (mRS) at discharge and after 3 months, and rate of cerebral hemorrhagic complications. Successful recanalization was defined as achieving Thrombolysis In Cerebral Infarction (TICI) of II or III. Results Sixteen patients received thrombectomy. The mean age was 67.8 ± 11 years and the mean NIHSS score was 12.3 ± 8.2. Eight patients treated within 6 hours of symptom onset were grouped as A and the other 8 patients treated beyond 6 hours (range, 6-120) were grouped as B. Successful recanalization was met in six patients (75%) for group A and 7 (87.5%) for group B. Favorable outcome occurred in 4 patients (50%) for group A and 5 (62.5%) for group B. Conclusion Our study supports the effectiveness and safety of endovascular mechanical thrombectomy in treating BA occlusion even 6 hours after symptom onset. PMID:24167791

  2. Endovascular Repair of Aortic Dissection in Marfan Syndrome: Current Status and Future Perspectives

    Directory of Open Access Journals (Sweden)

    Rosario Parisi

    2015-07-01

    Full Text Available Over the last decades, improvement of medical and surgical therapy has increased life expectancy in Marfan patients. Consequently, the number of such patients requiring secondary interventions on the descending thoracic aorta due to new or residual dissections, and distal aneurysm formation has substantially enlarged. Surgical and endovascular procedures represent two valuable options of treatment, both associated with advantages and drawbacks. The aim of the present manuscript was to review endovascular outcomes in Marfan syndrome and to assess the potential role of Thoracic Endovascular Aortic Repair (TEVAR in this subset of patients.

  3. Patch Test Negative Generalized Dermatitis.

    Science.gov (United States)

    Spiker, Alison; Mowad, Christen

    2016-01-01

    Allergic contact dermatitis is a common condition in dermatology. Patch testing is the criterion standard for diagnosis. However, dermatitis is not always caused by an allergen, and patch testing does not identify a culprit in every patient. Generalized dermatitis, defined as eczematous dermatitis affecting greater than 3 body sites, is often encountered in dermatology practice, especially patch test referral centers. Management for patients with generalized dermatitis who are patch test negative is challenging. The purpose of this article is to outline an approach to this challenging scenario and summarize the paucity of existing literature on patch test negative generalized dermatitis.

  4. Laser Welding Test Results with Gas Atmospheres in Welding Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Joung, Chang-Young; Hong, Jin-Tae; Ahn, Sung-Ho; Heo, Sung-Ho; Jang, Seo-Yun; Yang, Tae-Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    The weld beads of specimens welded under identical conditions in the helium and argon gas were cleaner, more regular, and steadier than those in a vacuum. The penetration depth of the FZ in the vacuum was much deeper than those in the helium and argon gas. To measure the irradiation properties of nuclear fuel in a test reactor, a nuclear fuel test rod instrumented with various sensors must be fabricated with assembly processes. A laser welding system to assemble the nuclear fuel test rod was designed and fabricated to develop various welding technologies of the fuel test rods to joint between a cladding tube and end-caps. It is an air-cooling optical fiber type and its emission modes are a continuous (CW) mode of which the laser generates continuous emission, and pulse (QCW) mode in which the laser internally generates sequences of pulses. We considered the system welding a sample in a chamber that can weld a specimen in a vacuum and inert gas atmosphere, and the chamber was installed on the working plate of the laser welding system. In the chamber, the laser welding process should be conducted to have no defects on the sealing area between a cladding tube and an end-cap.

  5. Welding of Thin Steel Plates by Hybrid Welding Process Combined TIG Arc with YAG Laser

    Science.gov (United States)

    Kim, Taewon; Suga, Yasuo; Koike, Takashi

    TIG arc welding and laser welding are used widely in the world. However, these welding processes have some advantages and problems respectively. In order to improve problems and make use of advantages of the arc welding and the laser welding processes, hybrid welding process combined the TIG arc with the YAG laser was studied. Especially, the suitable welding conditions for thin steel plate welding were investigated to obtain sound weld with beautiful surface and back beads but without weld defects. As a result, it was confirmed that the shot position of the laser beam is very important to obtain sound welds in hybrid welding. Therefore, a new intelligent system to monitor the welding area using vision sensor is constructed. Furthermore, control system to shot the laser beam to a selected position in molten pool, which is formed by TIG arc, is constructed. As a result of welding experiments using these systems, it is confirmed that the hybrid welding process and the control system are effective on the stable welding of thin stainless steel plates.

  6. Hybrid laser-arc welding

    DEFF Research Database (Denmark)

    Hybrid laser-arc welding (HLAW) is a combination of laser welding with arc welding that overcomes many of the shortfalls of both processes. This important book gives a comprehensive account of hybrid laser-arc welding technology and applications. The first part of the book reviews...... the characteristics of the process, including the properties of joints produced by hybrid laser-arc welding and ways of assessing weld quality. Part II discusses applications of the process to such metals as magnesium alloys, aluminium and steel as well as the use of hybrid laser-arc welding in such sectors as ship...... building and the automotive industry. With its distinguished editor and international team of contributors, Hybrid laser-arc welding, will be a valuable source of reference for all those using this important welding technology. Professor Flemming Ove Olsen works in the Department of Manufacturing...

  7. [New welding processes and health effects of welding].

    Science.gov (United States)

    La Vecchia, G Marina; Maestrelli, Piero

    2011-01-01

    This paper describes some of the recent developments in the control technology to enhance capability of Pulse Gas Metal Arc Welding. Friction Stir Welding (FSW) processing has been also considered. FSW is a new solid-state joining technique. Heat generated by friction at the rotating tool softens the material being welded. FSW can be considered a green and energy-efficient technique without deleterious fumes, gas, radiation, and noise. Application of new welding processes is limited and studies on health effects in exposed workers are lacking. Acute and chronic health effects of conventional welding have been described. Metal fume fever and cross-shift decline of lung function are the main acute respiratory effects. Skin and eyes may be affected by heat, electricity and UV radiations. Chronic effects on respiratory system include chronic bronchitis, a benign pneumoconiosis (siderosis), asthma, and a possible increase in the incidence of lung cancer. Pulmonary infections are increased in terms of severity, duration, and frequency among welders.

  8. Plug-welding of ODS cladding tube for BOR-60 irradiation. Welding condition setting. Device remodeling and welding

    International Nuclear Information System (INIS)

    Seki, Masayuki; Ishibashi, Fujio; Kono, Syusaku; Hirako, Kazuhito; Tsukada, Tatsuya

    2003-04-01

    Irradiation test in BOR-60 at RIAR to judge practical use prospect of ODS cladding tube at early stage is planned as Japan-Russia a joint research. RIAR does fuel design of fuel pin used for this joint research. JNC manufactures ODS cladding tube and bar materials (two steel kind of martensite and ferrite), upper endplug production. They are welded by pressurized resistance welding, and are inspected in JNC Tokai, transported to RIAR. And RIAR manufactures vibration packing fuel pin. On the upper endplug welding by pressurized resistance welding method, we worded on the problems such as decision of welding condition by changing the size and crystallization of cladding tube and the design of endplug, and the chucking device remodeling to correspond to the long scale cladding tube welding system (included handling) and of quality assurance method. Especially, use of long scale cladding tube caused problem that bending transformation occurred in cladding tube by welding pressure. However, we solved this problem by shortening the distance of cladding tube colette chuck and pressure receiving, and by putting the sleeve in an internal space of welding machine, losing the bending of cladding tube. Moreover, welding defects were occurred by the difference of an inside state, an inside defect and recrystallization of cladding tube. We solved the problem by inside grinding for the edge of tube, angle beam method by ultrasonic wave, and ultrasonic wave form confirmation. Manufacturing process with long scale cladding tube including heat-treatment to remove combustion return and remaining stress was established besides, Afterwards, welding of ODS cladding tube and upper endplug. As the quality assurance system, we constructed [Documented procedure (referred to JOYO)] based on [Document of the QA plan] by OEC. Welding and inspection were executed by the document procedure. It is thought that the quality assurance method become references for the irradiation test in JOYO in the

  9. Weld analysis and control system

    Science.gov (United States)

    Kennedy, Larry Z. (Inventor); Rodgers, Michael H. (Inventor); Powell, Bradley W. (Inventor); Burroughs, Ivan A. (Inventor); Goode, K. Wayne (Inventor)

    1994-01-01

    The invention is a Weld Analysis and Control System developed for active weld system control through real time weld data acquisition. Closed-loop control is based on analysis of weld system parameters and weld geometry. The system is adapted for use with automated welding apparatus having a weld controller which is capable of active electronic control of all aspects of a welding operation. Enhanced graphics and data displays are provided for post-weld analysis. The system provides parameter acquisition, including seam location which is acquired for active torch cross-seam positioning. Torch stand-off is also monitored for control. Weld bead and parent surface geometrical parameters are acquired as an indication of weld quality. These parameters include mismatch, peaking, undercut, underfill, crown height, weld width, puddle diameter, and other measurable information about the weld puddle regions, such as puddle symmetry, etc. These parameters provide a basis for active control as well as post-weld quality analysis and verification. Weld system parameters, such as voltage, current and wire feed rate, are also monitored and archived for correlation with quality parameters.

  10. Physical aspects of endovascular brachytherapy

    International Nuclear Information System (INIS)

    Kirisits, C.

    2001-11-01

    Restenosis is severely limiting the outcome of vascular interventions. In several clinical trials endovascular brachytherapy has shown to reduce the restenosis rate. Local radiotherapy to the injured vessel wall is a promising new type of treatment in order to inhibit a complex wound healing process resulting in cell proliferation and re-obstruction of the treated vessel. Treatment planning has to be based on the dose distribution in the vicinity of the sources used. Source strength was determined in terms of air kerma rate for gamma nuclides (Iridium-192) and absorbed dose to water at reference distance of 2 mm for beta nuclides (Strontium-90/Yttrium-90, Phosphor-32), respectively. Radial dose profiles and the Reference Isodose Length (RIL) were determined using the EGSnrc code and GafChromic film. Good agreement was found between both methods. In order to treat the entire clinical target length, the (RIL) is an essential value during treatment planning. Examples are described for different levels of treatment planing including recommendations for optimal choice and positioning of the radioactive devices inside the artery. IVUS based treatment planning is illustrated with superposition of isodoses on cross-sectional images. A calculation model for radioactive stents is presented in order to determine dose volume histograms in a retrospective analysis. Radiation protection issues for endovascular brachytherapy are discussed in detail. Personal dose for the involved personnel is estimated based on calculations and measurements. Beta ray dosimetry is performed with suitable detectors. In order to estimate the exposure to the patient the dose to organs at risk is calculated and compared to the dose from angiography. There is an additional radiation exposure to patients and personnel caused by endovascular brachytherapy, but the values are much smaller than those caused by diagnostic angiography. (author)

  11. Fine tuning of dwelling time in friction stir welding for preventing material overheating, weld tensile strength increase and weld nugget size decrease

    Directory of Open Access Journals (Sweden)

    Mijajlović Miroslav M.

    2016-01-01

    Full Text Available After successful welding, destructive testing into test samples from Al 2024-T351 friction stir butt welds showed that tensile strength of the weld improve along the joint line, while dimensions of the weld nugget decrease. For those welds, both the base material and the welding tool constantly cool down during the welding phase. Obviously, the base material became overheated during the long dwelling phase what made conditions for creation of joints with the reduced mechanical properties. Preserving all process parameters but varying the dwelling time from 5-27 seconds a new set of welding is done to reach maximal achievable tensile strength. An analytical-numerical-experimental model is used for optimising the duration of the dwelling time while searching for the maximal tensile strength of the welds

  12. Optimum welding condition of 2017 aluminum similar alloy friction welded joints

    Energy Technology Data Exchange (ETDEWEB)

    Tsujino R.; Ochi, H. [Osaka Inst. of Tech., Osaka (Japan); Morikawa, K. [Osaka Sangyo Univ., Osaka (Japan); Yamaguchi, H.; Ogawa, K. [Osaka Prefecture Univ., Osaka (Japan); Fujishiro, Y.; Yoshida, M. [Sumitomo Metal Technology Ltd., Hyogo (Japan)

    2002-07-01

    Usefulness of the statistical analysis for judging optimization of the friction welding conditions was investigated by using 2017 aluminum similar alloy, where many samples under fixed welding conditions were friction welded and analyzed statistically. In general, selection of the optimum friction welding conditions for similar materials is easy. However, it was not always the case for 2017 aluminum alloy. For optimum friction welding conditions of this material, it is necessary to apply relatively larger upset pressure to obtain high friction heating. Joint efficiencies obtained under the optimum friction welding conditions showed large shape parameter (m value) of Weibull distribution as well as in the dissimilar materials previously reported. The m value calculated on the small number of data can be substituted for m value on the 30 data. Therefore, m value is useful for practical use in the factory for assuming the propriety of the friction welding conditions. (orig.)

  13. Dual wire welding torch and method

    Science.gov (United States)

    Diez, Fernando Martinez; Stump, Kevin S.; Ludewig, Howard W.; Kilty, Alan L.; Robinson, Matthew M.; Egland, Keith M.

    2009-04-28

    A welding torch includes a nozzle with a first welding wire guide configured to orient a first welding wire in a first welding wire orientation, and a second welding wire guide configured to orient a second welding wire in a second welding wire orientation that is non-coplanar and divergent with respect to the first welding wire orientation. A method of welding includes moving a welding torch with respect to a workpiece joint to be welded. During moving the welding torch, a first welding wire is fed through a first welding wire guide defining a first welding wire orientation and a second welding wire is fed through a second welding wire guide defining a second welding wire orientation that is divergent and non-coplanar with respect to the first welding wire orientation.

  14. TIG welding method and TIG welding device

    International Nuclear Information System (INIS)

    Yoneda, Eishi

    1998-01-01

    The present invention provides a method of TIG welding for members having different heat capacities including a cladding tube and an end plug of a fuel rod to be used, for example, in a reactor, and a device therefor. Namely, in the TIG welding method, the flow rate of a sealed gas to the side of a member having smaller heat capacity is made greater than that on the side of the member having greater heat capacity bordered on the top end of a welding electrode. Since the sealed gas is jetted being localized relative to the welding electrode, arc is restricted in a region of the member having smaller heat capacity and is increased at a region having a larger heat capacity. As a result, the arc is localized, so that the heat input amount to the region having a large heat capacity is increased, and then a plurality of members at the abutting portion are melted uniformly thereby capable of obtaining a uniform molten pool. A bead is formed at the abutting portion thereby capable of obtaining a welded portion with less unevenness and having large strength. (I.S.)

  15. Endovascular Device Testing with Particle Image Velocimetry Enhances Undergraduate Biomedical Engineering Education

    Science.gov (United States)

    Nair, Priya; Ankeny, Casey J.; Ryan, Justin; Okcay, Murat; Frakes, David H.

    2016-01-01

    We investigated the use of a new system, HemoFlow™, which utilizes state of the art technologies such as particle image velocimetry to test endovascular devices as part of an undergraduate biomedical engineering curriculum. Students deployed an endovascular stent into an anatomical model of a cerebral aneurysm and measured intra-aneurysmal flow…

  16. de novo'' aneurysms following endovascular procedures

    International Nuclear Information System (INIS)

    Briganti, F.; Cirillo, S.; Caranci, F.; Esposito, F.; Maiuri, F.

    2002-01-01

    Two personal cases of ''de novo'' aneurysms of the anterior communicating artery (ACoA) occurring 9 and 4 years, respectively, after endovascular carotid occlusion are described. A review of the 30 reported cases (including our own two) of ''de novo'' aneurysms after occlusion of the major cerebral vessels has shown some features, including a rather long time interval after the endovascular procedure of up to 20-25 years (average 9.6 years), a preferential ACoA (36.3%) and internal carotid artery-posterior communicating artery (ICA-PCoA) (33.3%) location of the ''de novo'' aneurysms, and a 10% rate of multiple aneurysms. These data are compared with those of the group of reported spontaneous ''de novo'' aneurysms after SAH or previous aneurysm clipping. We agree that the frequency of ''de novo'' aneurysms after major-vessel occlusion (two among ten procedures in our series, or 20%) is higher than commonly reported (0 to 11%). For this reason, we suggest that patients who have been submitted to endovascular major-vessel occlusion be followed up for up to 20-25 years after the procedure, using non-invasive imaging studies such as MR angiography and high-resolution CT angiography. On the other hand, periodic digital angiography has a questionable risk-benefit ratio; it may be used when a ''de novo'' aneurysm is detected or suspected on non-invasive studies. The progressive enlargement of the ACoA after carotid occlusion, as described in our case 1, must be considered a radiological finding of risk for ''de novo'' aneurysm formation. (orig.)

  17. Stent fractures in the Hemobahn/Viabahn stent graft after endovascular popliteal aneurysm repair

    NARCIS (Netherlands)

    Tielliu, Ignace F. J.; Zeebregts, Clark J.; Vourliotakis, George; Bekkema, Foppe; van den Dungen, Jan J. A. M.; Prins, Ted R.; Verhoeven, Eric L. G.

    Objective: During the last decade, endovascular repair of popliteal artery aneurysms (PAAs) has become a valid alternative to open repair. This study analyzes the incidence and origin of stein graft fractures after endovascular repair, its impact on patency, and strategies to prevent fractures.

  18. Experimental investigation on the weld pool formation process in plasma keyhole arc welding

    Science.gov (United States)

    Van Anh, Nguyen; Tashiro, Shinichi; Van Hanh, Bui; Tanaka, Manabu

    2018-01-01

    This paper seeks to clarify the weld pool formation process in plasma keyhole arc welding (PKAW). We adopted, for the first time, the measurement of the 3D convection inside the weld pool in PKAW by stereo synchronous imaging of tungsten tracer particles using two sets of x-ray transmission systems. The 2D convection on the weld pool surface was also measured using zirconia tracer particles. Through these measurements, the convection in a wide range of weld pools from the vicinity of the keyhole to the rear region was successfully visualized. In order to discuss the heat transport process in a weld pool, the 2D temperature distribution on the weld pool surface was also measured by two-color pyrometry. The results of the comprehensive experimental measurement indicate that the shear force due to plasma flow is found to be the dominant driving force in the weld pool formation process in PKAW. Thus, heat transport in a weld pool is considered to be governed by two large convective patterns near the keyhole: (1) eddy pairs on the surface (perpendicular to the torch axis), and (2) eddy pairs on the bulk of the weld pool (on the plane of the torch). They are formed with an equal velocity of approximately 0.35 m s-1 and are mainly driven by shear force. Furthermore, the flow velocity of the weld pool convection becomes considerably higher than that of other welding processes, such as TIG welding and GMA welding, due to larger plasma flow velocity.

  19. Predictors of Reintervention After Endovascular Repair of Isolated Iliac Artery Aneurysm

    International Nuclear Information System (INIS)

    Zayed, Hany A.; Attia, Rizwan; Modarai, Bijan; Clough, Rachel E.; Bell, Rachel E.; Carrell, Tom; Sabharwal, Tarun; Reidy, John; Taylor, Peter R.

    2011-01-01

    The objective of this study was to identify factors predicting the need for reintervention after endovascular repair of isolated iliac artery aneurysm (IIAA). We reviewed prospectively collected database records of all patients who underwent endovascular repair of IIAA between 1999 and 2008. Detailed assessment of the aneurysms was performed using computed tomography angiography (CTA). Follow-up protocol included CTA at 3 months. If this showed no complication, then annual duplex scan was arranged. Multivariate analysis and analysis of patient survival and freedom from reintervention were performed using Kaplan–Meier life tables. Forty IIAAs (median diameter 44 mm) in 38 patients were treated (all men; median age 75 years), and median follow-up was 27 months. Endovascular repair of IIAA was required in 14 of 40 aneurysms (35%). The rate of type I endoleak was significantly higher with proximal landing zone (PLZ) diameter >30 mm in the aorta or >24 mm in the common iliac artery or distal landing zone (DLZ) diameter >24 mm (P = 0.03, 0.03, and 0.0014, respectively). Reintervention rate (RR) increased significantly with increased diameter or decreased length of PLZ; increased DLZ diameter; and endovascular IIAA repair (P = 0.005, 0.005, 0.02, and 0.02 respectively); however, RR was not significantly affected by length of PLZ or DLZ. Freedom-from-reintervention was 97, 93, and 86% at 12, 24, and 108 months. There was no in-hospital or aneurysm-related mortality. Endovascular IIAA repair is a safe treatment option. Proper patient selection is essential to decrease the RR.

  20. Virtual reality simulation for the optimization of endovascular procedures: current perspectives

    OpenAIRE

    Rudarakanchana, Nung; Van Herzeele, Isabelle; Desender, Liesbeth; Cheshire, Nicholas JW

    2015-01-01

    Nung Rudarakanchana,1 Isabelle Van Herzeele,2 Liesbeth Desender,2 Nicholas JW Cheshire1 1Department of Surgery, Imperial College London, London, UK; 2Department of Thoracic and Vascular Surgery, Ghent University Hospital, Ghent, BelgiumOn behalf of EVEREST (European Virtual reality Endovascular RESearch Team)Abstract: Endovascular technologies are rapidly evolving, often requiring coordination and cooperation between clinicians and technicians from diverse specialties. These multidisciplinary...

  1. Automatization of welding

    International Nuclear Information System (INIS)

    Iwabuchi, Masashi; Tomita, Jinji; Nishihara, Katsunori.

    1978-01-01

    Automatization of welding is one of the effective measures for securing high degree of quality of nuclear power equipment, as well as for correspondence to the environment at the site of plant. As the latest ones of the automatic welders practically used for welding of nuclear power apparatuses in factories of Toshiba and IHI, those for pipes and lining tanks are described here. The pipe welder performs the battering welding on the inside of pipe end as the so-called IGSCC countermeasure and the succeeding butt welding through the same controller. The lining tank welder is able to perform simultaneous welding of two parallel weld lines on a large thin plate lining tank. Both types of the welders are demonstrating excellent performance at the shops as well as at the plant site. (author)

  2. Electric arc welding gun

    Science.gov (United States)

    Luttrell, Edward; Turner, Paul W.

    1978-01-01

    This invention relates to improved apparatus for arc welding an interior joint formed by intersecting tubular members. As an example, the invention is well suited for applications where many similar small-diameter vertical lines are to be welded to a long horizontal header. The improved apparatus includes an arc welding gun having a specially designed welding head which is not only very compact but also produces welds that are essentially free from rolled-over solidified metal. The welding head consists of the upper end of the barrel and a reversely extending electrode holder, or tip, which defines an acute angle with the barrel. As used in the above-mentioned example, the gun is positioned to extend upwardly through the vertical member and the joint to be welded, with its welding head disposed within the horizontal header. Depending on the design of the welding head, the barrel then is either rotated or revolved about the axis of the vertical member to cause the electrode to track the joint.

  3. EndoVascular and Hybrid Trauma Management (EVTM) for Blunt Innominate Artery Injury with Ongoing Extravasation

    International Nuclear Information System (INIS)

    Bilos, Linda; Pirouzram, Artai; Toivola, Asko; Vidlund, Mårten; Cha, Soon Ok; Hörer, Tal

    2017-01-01

    Innominate artery (IA) traumatic injuries are rare but life-threatening, with high mortality and morbidity. Open surgical repair is the treatment of choice but is technically demanding. We describe a case of blunt trauma to the IA with ongoing bleeding, treated successfully by combined (hybrid) endovascular and open surgery. The case demonstrates the immediate usage of modern endovascular and surgical tools as part of endovascular and hybrid trauma management.

  4. EndoVascular and Hybrid Trauma Management (EVTM) for Blunt Innominate Artery Injury with Ongoing Extravasation

    Energy Technology Data Exchange (ETDEWEB)

    Bilos, Linda, E-mail: linda.bilos@regionorebrolan.se; Pirouzram, Artai; Toivola, Asko; Vidlund, Mårten; Cha, Soon Ok; Hörer, Tal [Örebro University Hospital and Örebro University, Department of Cardiothoracic and Vascular Surgery, Faculty of Medicine and Health (Sweden)

    2017-01-15

    Innominate artery (IA) traumatic injuries are rare but life-threatening, with high mortality and morbidity. Open surgical repair is the treatment of choice but is technically demanding. We describe a case of blunt trauma to the IA with ongoing bleeding, treated successfully by combined (hybrid) endovascular and open surgery. The case demonstrates the immediate usage of modern endovascular and surgical tools as part of endovascular and hybrid trauma management.

  5. The 100 most cited articles in the endovascular management of intracranial aneurysms.

    Science.gov (United States)

    Maingard, Julian; Phan, Kevin; Ren, Yifan; Kok, Hong Kuan; Thijs, Vincent; Hirsch, Joshua A; Lee, Michael J; Chandra, Ronil V; Brooks, Duncan Mark; Asadi, Hamed

    2018-01-19

    Endovascular interventions for intracranial aneurysms have evolved substantially over the past several decades. A citation rank list is used to measure the scientific and/or clinical impact of an article. Our objective was to identify and analyze the characteristics of the 100 most cited articles in the field of endovascular therapy for intracranial aneurysms. We performed a retrospective bibliometric analysis between July and August 2017. Articles were searched on the Science Citation Index Expanded database using Web of Science in order to identify the most cited articles in the endovascular therapy of intracranial aneurysms since 1945. Using selected key terms ('intracranial aneurysm', 'aneurysm', 'aneurysmal subarachnoid', 'endovascular', 'coiling', 'stent-assisted', 'balloon-assisted', 'flow-diversion') yielded a total of 16 314 articles. The top 100 articles were identified and analyzed to extract relevant information, including citation count, authorship, article type, subject matter, institution, country of origin, and year of publication. Citations for the top 100 articles ranged from 133 to 1832. All articles were cited an average of 27 times per year. There were 45 prospective studies, including 7 level-II randomized controlled trials. Most articles were published in the 2000s (n=53), and the majority constituted level III or level IV evidence. Half of the top 100 articles arose from the USA. This study provides a comprehensive overview of the most cited articles in the endovascular management of intracranial aneurysms. It recognizes the contributions made by key authors and institutions, providing an important framework to an enhanced understanding of the evidence behind the endovascular treatment of aneurysms. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. A novel weld seam detection method for space weld seam of narrow butt joint in laser welding

    Science.gov (United States)

    Shao, Wen Jun; Huang, Yu; Zhang, Yong

    2018-02-01

    Structured light measurement is widely used for weld seam detection owing to its high measurement precision and robust. However, there is nearly no geometrical deformation of the stripe projected onto weld face, whose seam width is less than 0.1 mm and without misalignment. So, it's very difficult to ensure an exact retrieval of the seam feature. This issue is raised as laser welding for butt joint of thin metal plate is widely applied. Moreover, measurement for the seam width, seam center and the normal vector of the weld face at the same time during welding process is of great importance to the welding quality but rarely reported. Consequently, a seam measurement method based on vision sensor for space weld seam of narrow butt joint is proposed in this article. Three laser stripes with different wave length are project on the weldment, in which two red laser stripes are designed and used to measure the three dimensional profile of the weld face by the principle of optical triangulation, and the third green laser stripe is used as light source to measure the edge and the centerline of the seam by the principle of passive vision sensor. The corresponding image process algorithm is proposed to extract the centerline of the red laser stripes as well as the seam feature. All these three laser stripes are captured and processed in a single image so that the three dimensional position of the space weld seam can be obtained simultaneously. Finally, the result of experiment reveals that the proposed method can meet the precision demand of space narrow butt joint.

  7. Endovascular treatment of three traumatic lesions of the vertebral artery

    International Nuclear Information System (INIS)

    Galvis, Victor Raul; Medina V, Francisco Jose

    2007-01-01

    The purpose is to expose the results of the endovascular treatment of three traumatic lesions of the vertebral artery. Methods: in the period from October 2005 to May 2006, three patients with traumatic lesions in the vertebral artery were treated by endovascular therapy with an age average of 32 years. All the procedures were carried out using subtraction digital angiography under anesthesiology supervision and were started with a 5,000 IU heparin bolus, previous antiplatelet medication with clopidogrel. For the treatment of the lesions covered stents and coils were used. results: there were three documented cases of traumatic lesions of the vertebral artery treated by endovascular therapy, in two cases arteriovenous fistulas were identified (between vertebral artery and internal jugular vein) with associated pseudo aneurysms, and in one case a pseudo aneurysm without fistula was found. The first patient was treated with placement of a covered stent, in a second patient the lesion was occluded with coils and a third patient required stent and coils with satisfactory repair of the lesions. Complications were not presented as a result of the procedures. Conclusions: the endovascular treatment for traumatic lesions of the vertebral artery is an alternative with minimum morbidity and reasonable costs avoiding the open surgery and conserving the permeability of the vessel when it is possible

  8. Investigation into Variations of Welding Residual Stresses and Redistribution Behaviors for Different Repair Welding Widths

    International Nuclear Information System (INIS)

    Park, Chiyong; Lee, Hweesueng; Huh, Namsu

    2014-01-01

    In this study, we investigated the variations in welding residual stresses in dissimilar metal butt weld due to width of repair welding and re-distribution behaviors resulting from similar metal welding (SMW) and mechanical loading. To this end, detailed two-dimensional axi-symmetric finite element (FE) analyses were performed considering five different repair welding widths. Based on the FE results, we first evaluated the welding residual stress distributions in repair welding. We then investigated the re-distribution behaviors of the residual stresses due to SMW and mechanical loads. It is revealed that large tensile welding residual stresses take place in the inner surface and that its distribution is affected, provided repair welding width is larger than certain value. The welding residual stresses resulting from repair welding are remarkably reduced due to SMW and mechanical loading, regardless of the width of the repair welding

  9. Certification of a weld produced by friction stir welding

    Science.gov (United States)

    Obaditch, Chris; Grant, Glenn J

    2013-10-01

    Methods, devices, and systems for providing certification of friction stir welds are disclosed. A sensor is used to collect information related to a friction stir weld. Data from the sensor is compared to threshold values provided by an extrinsic standard setting organizations using a certification engine. The certification engine subsequently produces a report on the certification status of the weld.

  10. Laser beam welding and friction stir welding of 6013-T6 aluminium alloy sheet

    International Nuclear Information System (INIS)

    Braun, R.; Dalle Donne, C.; Staniek, G.

    2000-01-01

    Butt welds of 1.6 mm thick 6013-T6 sheet were produced using laser beam welding and friction stir welding processes. Employing the former joining technique, filler powders of the alloys Al-5%Mg and Al-12%Si were used. Microstructure, hardness profiles, tensile properties and the corrosion behaviour of the welds in the as-welded condition were investigated. The hardness in the weld zone was lower compared to that of the base material in the peak-aged temper. Hardness minima were measured in the fusion zone and in the thermomechanically affected zone for laser beam welded and friction stir welded joints, respectively. Metallographic and fractographic examinations revealed pores in the fusion zone of the laser beam welds. Porosity was higher in welds made using the filler alloy Al-5%Mg than using the filler metal Al-12%Si. Transmission electron microscopy indicated that the β '' (Mg 2 Si) hardening precipitates were dissolved in the weld zone due to the heat input of the joining processes. Joint efficiencies achieved for laser beam welds depended upon the filler powders, being about 60 and 80% using the alloys Al-5%Mg and Al-12%Si, respectively. Strength of the friction stir weld approached over 80% of the ultimate tensile strength of the 6013-T6 base material. Fracture occurred in the region of hardness minima unless defects in the weld zone led to premature failure. The heat input during welding did not cause a degradation of the corrosion behaviour of the welds, as found in continuous immersion tests in an aqueous chloride-peroxide solution. In contrast to the 6013-T6 parent material, the weld zone was not sensitive to intergranular corrosion. Alternate immersion tests in 3.5% NaCl solution indicated high stress corrosion cracking resistance of the joints. For laser beam welded sheet, the weld zone of alternately immersed specimens suffered severe degradation by pitting and intergranular corrosion, which may be associated with galvanic coupling of filler metal and

  11. Recovery of Third Nerve Palsy after Endovascular Packing of Internal Carotid-Posterior Communicating Artery Aneurysms

    Science.gov (United States)

    Mavilio, N.; Pisani, R.; Rivano, C.; Testa, V.; Spaziante, R.; Rosa, M.

    2000-01-01

    Summary Endovascular packing of intracranial aneurysm with preservation of the parent vessel has become in many cases a valid alternative to surgical clipping. Regression of oculomotor disorders after clipping of internal carotid-posterior communicating artery (ICA-PCoA) aneurysms has been well assessed. This report focuses on the reversal of third nerve palsy after endovascular packing of ICA-PCoA aneurysms. To this end, clinical appearances, neuroradiological features, and endovascular interventional procedures of six treated patient are reported and discussed in the light of the very few previous case observations found in the literature. Results indicate that endovascular packing of ICA-PCoA aneurysms may produce effective recovery of correlated third nerve dysfunction. PMID:20667199

  12. Process for quality assurance of welded joints for electrical resistance point welding

    International Nuclear Information System (INIS)

    Schaefer, R.; Singh, S.

    1977-01-01

    In order to guarantee the reproducibility of welded joints of even quality (above all in the metal working industry), it is proposed that before starting resistance point welding, a preheating current should be allowed to flow at the site of the weld. A given reduction of the total resistance at the site of the weld should effect the time when the preheating current is switched over to welding current. This value is always predetermined empirically. Further possibilities of controlling the welding process are described, where the measurement of thermal expansion of the parts is used. A standard welding time is given. The rated course of electrode movement during the process can be predicted and a running comparison of nominal and actual values can be carried out. (RW) [de

  13. Weld nugget formation in resistance spot welding of new lightweight sandwich material

    DEFF Research Database (Denmark)

    Sagüés Tanco, J.; Nielsen, Chris Valentin; Chergui, Azeddine

    2015-01-01

    Weldability of a new lightweight sandwich material, LITECOR®, by resistance spot welding is analyzed by experiments and numerical simulations. The spot welding process is accommodated by a first pulse squeezing out the non-conductive polymer core of the sandwich material locally to allow metal......–metal contact. This is facilitated by the use of a shunt tool and is followed by a second pulse for the actual spot welding and nugget formation. A weldability lobe in the time-current space of the second pulse reveals a process window of acceptable size for automotive assembly lines. Weld growth curves...... with experimental results in the range of welding parameters leading to acceptable weld nugget sizes. The validated accuracy of the commercially available software proves the tool useful for assisting the choice of welding parameters....

  14. Endovascular treatment of very small intracranial aneurysms

    DEFF Research Database (Denmark)

    Iskandar, A; Nepper-Rasmussen, J

    2011-01-01

    to large aneurysms (> 3 mm). However the data also suggest that endovascular treatment of very small aneurysms might be associated with an increased risk of procedural ruptures and mortality. At nine-month follow-up results indicate significantly less compaction in the very small aneurysms....... endovascular treatment was attempted in 956 consecutive intracranial aneurysms. Of 956 aneurysms, 111 aneurysms were very small aneurysms with a maximal diameter of 3 mm or less. We conducted a retrospective analysis of angiographic and clinical outcome following coiling of very small aneurysms...... aneurysms and less than 90% aneurysm occlusion in six aneurysms. Complications occurred in the treatment of 15 aneurysms, including eight procedural ruptures, six thromboembolic events and one case of early hemorrhage. Compared with larger aneurysms, treatment of very small aneurysms was associated...

  15. Residual stress by repair welds

    International Nuclear Information System (INIS)

    Mochizuki, Masahito; Toyoda, Masao

    2003-01-01

    Residual stress by repair welds is computed using the thermal elastic-plastic analysis with phase-transformation effect. Coupling phenomena of temperature, microstructure, and stress-strain fields are simulated in the finite-element analysis. Weld bond of a plate butt-welded joint is gouged and then deposited by weld metal in repair process. Heat source is synchronously moved with the deposition of the finite-element as the weld deposition. Microstructure is considered by using CCT diagram and the transformation behavior in the repair weld is also simulated. The effects of initial stress, heat input, and weld length on residual stress distribution are studied from the organic results of numerical analysis. Initial residual stress before repair weld has no influence on the residual stress after repair treatment near weld metal, because the initial stress near weld metal releases due to high temperature of repair weld and then stress by repair weld regenerates. Heat input has an effect for residual stress distribution, for not its magnitude but distribution zone. Weld length should be considered reducing the magnitude of residual stress in the edge of weld bead; short bead induces high tensile residual stress. (author)

  16. Handbook of Plastic Welding

    DEFF Research Database (Denmark)

    Islam, Aminul

    The purpose of this document is to summarize the information about the laser welding of plastic. Laser welding is a matured process nevertheless laser welding of micro dimensional plastic parts is still a big challenge. This report collects the latest information about the laser welding of plastic...... materials and provides an extensive knowhow on the industrial plastic welding process. The objectives of the report include: - Provide the general knowhow of laser welding for the beginners - Summarize the state-of-the-art information on the laser welding of plastics - Find the technological limits in terms...... of design, materials and process - Find the best technology, process and machines adaptive to Sonion’s components - Provide the skills to Sonion’s Design Engineers for successful design of the of the plastic components suitable for the laser welding The ultimate goal of this report is to serve...

  17. Boosting Active Contours for Weld Pool Visual Tracking in Automatic Arc Welding

    DEFF Research Database (Denmark)

    Liu, Jinchao; Fan, Zhun; Olsen, Søren Ingvor

    2015-01-01

    Detecting the shape of the non-rigid molten metal during welding, so-called weld pool visual sensing, is one of the central tasks for automating arc welding processes. It is challenging due to the strong interference of the high-intensity arc light and spatters as well as the lack of robust...... approaches to detect and represent the shape of the nonrigid weld pool. We propose a solution using active contours including an prior for the weld pool boundary composition. Also, we apply Adaboost to select a small set of features that captures the relevant information. The proposed method is applied...... to weld pool tracking and the presented results verified its feasibility....

  18. Endovascular treatment for arterial injuries of skull base

    International Nuclear Information System (INIS)

    Li Tianxiao; Bai Weixing; Zai Suiting; Wang Ziliang; Xue Jiangyu

    2008-01-01

    Objective: To explore the role of endovascular techniques in treatment for arterial injuries of skull base. Methods: A total of 53 consecutive cases suffered from skull base arterial injuries were enrolled in our hospital from Oct 2004 to May 2007, including 44 male and 9 female cases with average age of 23.3 years. Thirty-nine cases presented with pulsatile exophthalmos and intracranial vascular murmur, cerchnus and dysphagia in another 9, epistaxis in the remaining 5 cases. Diagnosis of 39 carotid cavernous fistulae (CCF)and 14 carotid pseudoaneurysm were performed by angiography (DSA). Alternative endovascular procedures were performed depending on lesions characteristics and follow-up was done by telephone and outpatient work up. Results: Procedures were performed involving 56 carotid arteries in all 53 cases including 34 CCF with embolization of detachable balloon(33 cases), 3 with balloon and coils, and 3 by stent-graft placement. 8 carotid pseudoaneurysms were cured by parent artery occlusion with balloon, 2 experienced endovascular isolation with balloon and coils, and 4 with stent-graft. Follow-up for mean 9.5 months (range from 2 to 25 months) revealed that the chief symptoms of 45 cases (85%) were relieved within 6 months after the procedure but ocular movement and visual disorder remained in 8 cases (15%)till 12 months. Six pseudoaneurysms and 3 residual leak were found in reexamination, of which 2 cases underwent intervention again 2 and 3 months later due to dural arterial-venous fistula in cavernous sinus, respectively. Conclusions: Endovascular treatment is safe and effective therapeutic option with minimal invasion for skull base arterial injuries. Detachable balloon embolization is the first choice for CCF and carotid pseudoaneurysm. Spring coil packing and stent-graft implantation should be in alternation as combination for special cases. (authors)

  19. Analysis of welding distortion due to narrow-gap welding of upper port plug

    International Nuclear Information System (INIS)

    Biswas, Pankaj; Mandal, N.R.; Vasu, Parameswaran; Padasalag, Shrishail B.

    2010-01-01

    Narrow-gap welding is a low distortion welding process. This process allows very thick plates to be joined using fewer weld passes as compared to conventional V-groove or double V-groove welding. In case of narrow-gap arc welding as the heat input and weld volume is low, it reduces thermal stress leading to reduction of both residual stress and distortion. In this present study the effect of narrow-gap welding was studied on fabrication of a scaled down port plug in the form of a trapezoidal box made of 10 mm thick mild steel (MS) plates using gas tungsten arc welding (GTAW). Inherent strain method was used for numerical prediction of resulting distortions. The numerical results compared well with that of the experimentally measured distortion. The validated numerical scheme was used for prediction of weld induced distortion due to narrow-gap welding of full scale upper port plug made of 60 mm thick SS316LN material as is proposed for use in ITER project. It was observed that it is feasible to fabricate the said port plug keeping the distortions minimum within about 7 mm using GTAW for root pass welding followed by SMAW for filler runs.

  20. Welding processes handbook

    CERN Document Server

    Weman, Klas

    2003-01-01

    Deals with the main commercially significant and commonly used welding processes. This title takes the student or novice welder through the individual steps involved in each process in an easily understood way. It covers many of the requirements referred to in European Standards including EN719, EN 729, EN 729 and EN 287.$bWelding processes handbook is a concise, explanatory guide to the main commercially significant and commonly-used welding processes. It takes the novice welder or student through the individual steps involved in each process in a clear and easily understood way. It is intended to provide an up-to-date reference to the major applications of welding as they are used in industry. The contents have been arranged so that it can be used as a textbook for European welding courses in accordance with guidelines from the European Welding Federation. Welding processes and equipment necessary for each process are described so that they can be applied to all instruction levels required by the EWF and th...

  1. Ultrasonic Stir Welding

    Science.gov (United States)

    Nabors, Sammy

    2015-01-01

    NASA Marshall Space Flight Center (MSFC) developed Ultrasonic Stir Welding (USW) to join large pieces of very high-strength metals such as titanium and Inconel. USW, a solid-state weld process, improves current thermal stir welding processes by adding high-power ultrasonic (HPU) energy at 20 kHz frequency. The addition of ultrasonic energy significantly reduces axial, frictional, and shear forces; increases travel rates; and reduces wear on the stir rod, which results in extended stir rod life. The USW process decouples the heating, stirring, and forging elements found in the friction stir welding process allowing for independent control of each process element and, ultimately, greater process control and repeatability. Because of the independent control of USW process elements, closed-loop temperature control can be integrated into the system so that a constant weld nugget temperature can be maintained during welding.

  2. The effects of welded joint characteristics on its properties in HDPE thermal fusion welding

    Science.gov (United States)

    Dai, Hongbin; Peng, Jun

    2017-05-01

    In this paper, PE100 pipes with the diameter of 200 mm and the thickness of 11.9 mm were used as material. The welded joints were obtained in different welding pressures with the optimal welding temperature of 220∘C. Reheating process on the welded joints with the temperature of 130∘C was carried out. The joints exhibited X-type, and the cause of X-type joints was discussed. The temperature field in the forming process of welded joints was measured, and tensile and bending tests on welded joints were carried out. The fracture surface of welded joints was observed by scanning electron microscopy (SEM), and crystallinity calculation was taken by X-ray diffraction (XRD). The mechanism of X-type weld profile effects on welded joints properties was analyzed. It was concluded that the mechanical properties of welded joints decrease with the reduced X distance between lines.

  3. Endovascular revascularization for aortoiliac atherosclerotic disease

    Directory of Open Access Journals (Sweden)

    Aggarwal V

    2016-03-01

    Full Text Available Vikas Aggarwal,1 Stephen W Waldo,2,3 Ehrin J Armstrong2,3 1Prairie Heart Institute, St John's Hospital, Springfield, IL, 2Section of Cardiology, Denver Veterans Affairs Medical Center, 3Section of Cardiology, University of Colorado, Aurora, CO, USA Abstract: Atherosclerotic iliac artery disease is increasingly being treated with endovascular techniques. A number of new stent technologies can be utilized with high long-term patency, including self-expanding stents, balloon-expandable stents, and covered stents, but comparative data on these stent types and in more complex lesions are lacking. This article provides a review of currently available iliac stent technologies, as well as complex procedural aspects of iliac artery interventions, including approaches to the treatment of iliac bifurcation disease, long segment occlusions, choice of stent type, and treatment of iliac artery in-stent restenosis. Keywords: peripheral artery disease, iliac artery, balloon expandable stent, self expanding stent, covered stent, claudication, endovascular

  4. Recent advances in the TIG welding process and the application of the welding of nuclear components

    International Nuclear Information System (INIS)

    Lucas, W.; Males, B.O.

    1982-01-01

    Recent advances in the field of precision arc welding techniques and infacilities for production of nuclear power plant components arc presented. Of the precision welding techniques, pulsed TIG welding, pulsed plasma arc welding, hot-wire TIG welding, and pulsed inert-gas metal-arc welding. In the field of weld cladding, GMA plasma welding is cited as an alternative to submerged-arc welding with a strip electrode. Transistors and computer-controlled welding systems get a special mention. Applications of TIG welding in the UK are cited, e.g. welding of components for the AGR nuclear power plant and construction of equipment for repair work in feedwater pipes of the MAGNOX reactor. (orig.) [de

  5. Development of stroke-induced quadriplegia after endovascular repair of blunt aortic injury pseudoaneurysm.

    Science.gov (United States)

    Amoudi, Abdullah S; Merdad, Anas A; Makhdoom, Ahmed Q; Jamjoom, Reda A

    2015-01-01

    Endovascular repair of blunt aortic injury is now a first-line approach in management. This can warrant coverage of the left subclavian artery (LSA), which could lead to posterior strokes. In this case report, we present a severe complication of endovascular repair of a traumatic aortic aneurysm. A 53-year-old man presented with blunt aortic injury, endovascular repair was carried out where the left subclavian artery was covered. The intervention had a 100% technical success. Twelve hours later, he was discovered to have quadriplegia, a CT scan showed a large left cerebellar infarction extending to the medulla oblongata and proximal spinal cord. Strokes complicate 3% of thoracic endovascular aortic repairs, 80% of those strokes occur in patients who had their LSA`s covered. Most patients however, tolerate the coverage. Although our patient had a dominant right vertebral artery, and lacked risks for these strokes, he developed an extensive stroke that left him quadriplegic.

  6. Patch-augmented rotator cuff repair: influence of the patch fixation technique on primary biomechanical stability.

    Science.gov (United States)

    Jung, Christian; Spreiter, Gregor; Audigé, Laurent; Ferguson, Stephen J; Flury, Matthias

    2016-05-01

    There is an ongoing debate about the potential of patch augmentation to improve biomechanical stability and healing associated with rotator cuff repair. The biomechanical properties of three different patch-augmented rotator cuff repair techniques were assessed in vitro and compared with a standard repair. Dermal collagen patch augmentation may increase the primary stability and strength of the repaired tendon in vitro, depending on the technique used for patch application. Forty cadaveric sheep shoulders with dissected infraspinatus tendons were randomized into four groups (n = 10/group) for tendon repair using a knotless double-row suture anchor technique. A xenologous dermal extracellular matrix patch was used for augmentation in the three test groups using an "integrated", "cover", or "hybrid" technique. Tendons were preconditioned, cyclically loaded from 10 to 30 N at 1 Hz, and then loaded monotonically to failure. Biomechanical properties and the mode of failure were evaluated. Patch augmentation significantly increased the maximum load at failure by 61 % in the "cover" technique test group (225.8 N) and 51 % in the "hybrid" technique test group (211.4 N) compared with the non-augmented control group (140.2 N) (P ≤ 0.015). For the test group with "integrated" patch augmentation, the load at failure was 28 % lower (101.6 N) compared with the control group (P = 0.043). There was no significant difference in initial and linear stiffness among the four experimental groups. The most common mode of failure was tendon pullout. No anchor dislocation, patch disruption or knot breakage was observed. Additional patch augmentation with a collagen patch influences the biomechanical properties of a rotator cuff repair in a cadaveric sheep model. Primary repair stability can be significantly improved depending on the augmentation technique.

  7. WELDING TORCH

    Science.gov (United States)

    Correy, T.B.

    1961-10-01

    A welding torch into which water and inert gas are piped separately for cooling and for providing a suitable gaseous atmosphere is described. A welding electrode is clamped in the torch by a removable collet sleeve and a removable collet head. Replacement of the sleeve and head with larger or smaller sleeve and head permits a larger or smaller welding electrode to be substituted on the torch. (AEC)

  8. Welding procedure specification for arc welding of St 52-3N steel plates with covered electrodes

    International Nuclear Information System (INIS)

    Cvetkovski, S.; Slavkov, D.; Magdeski, J.

    2003-01-01

    In this paper the results of approval welding technology for arc welding of plates made of St 52-3N steel are presented. Metal arc welding with covered electrode is used welding process. Test specimens are butt welded in different welding positions P A , P F , P C and P D . Before start welding preliminary welding procedure was prepared. After welding of test specimens non destructive and destructive testing was performed. Obtained results were compared with standard DIN 17100 which concerns to chemical composition and mechanical properties of base material. It was confirmed that in all cases mechanical properties of welded joint are higher than those of base material, so preliminary welding procedure (pWTS) can be accepted as welding procedure specification WPS for metal arc welding of St52-3N steel. (Original)

  9. Variant selection of martensites in steel welded joints with low transformation temperature weld metals

    International Nuclear Information System (INIS)

    Takahashi, Masaru; Yasuda, Hiroyuki Y.

    2013-01-01

    Highlights: ► We examined the variant selection of martensites in the weld metals. ► We also measured the residual stress developed in the butt and box welded joints. ► 24 martensite variants were randomly selected in the butt welded joint. ► High tensile residual stress in the box welded joint led to the strong variant selection. ► We discussed the rule of the variant selection focusing on the residual stress. -- Abstract: Martensitic transformation behavior in steel welded joints with low transformation temperature weld (LTTW) metal was examined focusing on the variant selection of martensites. The butt and box welded joints were prepared with LTTW metals and 980 MPa grade high strength steels. The residual stress of the welded joints, which was measured by a neutron diffraction technique, was effectively reduced by the expansion of the LTTW metals by the martensitic transformation during cooling after the welding process. In the LTTW metals, the retained austenite and martensite phases have the Kurdjumov–Sachs (K–S) orientation relationship. The variant selection of the martensites in the LTTW metals depended strongly on the type of welded joints. In the butt welded joint, 24 K–S variants were almost randomly selected while a few variants were preferentially chosen in the box welded joint. This suggests that the high residual stress developed in the box welded joint accelerated the formation of specific variants during the cooling process, in contrast to the butt welded joint with low residual stress

  10. Corrosion resistance of «tube – tubesheet» weld joint obtained by friction welding

    Directory of Open Access Journals (Sweden)

    RIZVANOV Rif Garifovich

    2017-08-01

    Full Text Available Shell-and-tube heat exchangers are widely applied for implementation of various processes at ventures of fuel and energy complex. Cost of production and reliability of heat exchangers of this type is to a wide extent determined by corresponding characteristics of tube bundle, «tube – tubesheet» is its typical joint in particular when welding operations are used in order to attach tubes to tubesheet in addition to expansion. When manufacturing such equipment of heat-resistant chrome-bearing or chromium-molybdenum steels including steel 15H5M, the process of fixed joint manufacturing gets significantly more complicated and costly due to the necessity to use thermal treatment before, during and after welding (this problem is particularly applicable for manufacturing of large-size equipment. One of the options to exclude thermal treatment from manufacturing process is to use «non-arc» welding methods – laser welding, explosion welding as well as friction welding. Use of each of the welding methods mentioned above during production of heat-exchange equipment has its process challenges and peculiarities. This article gives a comparative analysis of weld structure and distribution of electrode potentials of welded joints and parent metal of the joints simulating welding of tube to tubesheet of steel 15H5M using the following welding methods: shielded manual arc welding, tungsten-arc inert-gas welding and friction welding. Comparative analysis of macro- and microstructures of specific zones of the studied welded joints showed that the joints produced by arc welding methods do not exhibit evident inhomogeneity of the structure after application of thermal treatment which is explained by the correctness of thermal treatment. Joints obtained via friction welding are characterized by structural inhomogeneity of the welded joint zone metal microstructure. The ultra-fine-grained structure obtained as a result of friction welding makes it possible to

  11. The Effect of Weld Reinforcement and Post-Welding Cooling Cycles on Fatigue Strength of Butt-Welded Joints under Cyclic Tensile Loading.

    Science.gov (United States)

    Araque, Oscar; Arzola, Nelson; Hernández, Edgar

    2018-04-12

    This research deals with the fatigue behavior of butt-welded joints, by considering the geometry and post-welding cooling cycles, as a result of cooling in quiet air and immersed in water. ASTM A-36 HR structural steel was used as the base metal for the shielded metal arc welding (SMAW) process with welding electrode E6013. The welding reinforcement was 1 mm and 3 mm, respectively; axial fatigue tests were carried out to determine the life and behavior in cracks propagation of the tested welded joints, mechanical characterization tests of properties in welded joints such as microhardness, Charpy impact test and metallographic analysis were carried out. The latter were used as input for the analysis by finite elements which influence the initiation and propagation of cracks and the evaluation of stress intensity factors (SIF). The latter led to obtaining the crack propagation rate and the geometric factor. The tested specimens were analyzed, by taking photographs of the cracks at its beginning in order to make a count of the marks at the origin of the crack. From the results obtained and the marks count, the fatigue crack growth rate and the influence of the cooling media on the life of the welded joint are validated, according to the experimental results. It can be concluded that the welded joints with a higher weld reinforcement have a shorter fatigue life. This is due to the stress concentration that occurs in the vicinity of the weld toe.

  12. Distortion Control during Welding

    NARCIS (Netherlands)

    Akbari Pazooki, A.M.

    2014-01-01

    The local material expansion and contraction involved in welding result in permanent deformations or instability i.e., welding distortion. Considerable efforts have been made in controlling welding distortion prior to, during or after welding. Thermal Tensioning (TT) describes a group of in-situ

  13. Arc-weld pool interactions

    International Nuclear Information System (INIS)

    Glickstein, S.S.

    1978-08-01

    The mechanisms involved in arc-weld pool interactions are extremely complex and no complete theory is presently available to describe much of the phenomena observed during welding. For the past several years, experimental and analytical studies have been undertaken at the Bettis Atomic Power Laboratory to increase basic understanding of the gas tungsten arc welding process. These studies have included experimental spectral analysis of the arc in order to determine arc temperature and analytical modeling of the arc and weld puddle. The investigations have been directed toward determining the cause and effects of variations in the energy distribution incident upon the weldment. In addition, the effect of weld puddle distortion on weld penetration was investigated, and experimental and analytical studies of weld process variables have been undertaken to determine the effects of the variables upon weld penetration and configuration. A review of the results and analysis of these studies are presented

  14. Early experience with transfemoral endovascular aneurysm management (TEAM) in the treatment of aortic aneurysms

    NARCIS (Netherlands)

    Balm, R.; Eikelboom, B. C.; May, J.; Bell, P. R.; Swedenborg, J.; Collin, J.

    1996-01-01

    OBJECTIVES: To evaluate the early experience with transfemoral endovascular aortic aneurysm management using the Endovascular Grafting System. DESIGN: Multi-centre prospective evaluation of the implantation procedure and early results (median follow-up 153 days). SETTING: Department of Surgery,

  15. Welding electrode for peripheral welds of A-1 reactor pressure vessel

    International Nuclear Information System (INIS)

    Lakatos, L.

    1975-01-01

    The properties are outlined of the VUZ-AC1-52 welding electrode used in welding the Bohunice A-1 reactor pressure vessel. The mechanical properties of welded joints after the final thermal treatment are summed up. (J.K.)

  16. Combination of endovascular graft exclusion and drug therapy in AAA with hypertension or hyperglycemia.

    Science.gov (United States)

    Wang, Dile; Qu, Bihui; He, Tao

    2017-08-01

    The objective of the present study was to evaluate the efficacy of combination of endovascular graft exclusion and drugs for hypertension/hyperglycemia for the treatment of abdominal aortic aneurysm (AAA). We analyzed 156 patients with AAA. Eighty-four patients were hypertensive and 72 were hyperglycemic. After endovascular graft exclusion, hypertensive patients were divided into four groups and treated with cyclopenthiazide, reserpine, propranolol, and placebo respectively. Hyperglycemic patients were divided into three groups and treated with metformin, insulin, and placebo respectively. Body temperature and peripheral blood leukocytes were measured at day 1, 2, 7, and 14 after endovascular graft exclusion. Size of AAAs, blood pressure, and blood sugar were measured again after 1 year. In hypertensive patients, the size of AAAs reduced after endovascular graft exclusion, while the combined treatments with cyclopenthiazide, reserpine, or propranolol helped to reduce blood pressure (blood pressure decrease AAA size decreased in the control group (PAAAs reduced after endovascular graft exclusion. Combined treatment with Metformin and Insulin reduced blood sugar (control, blood sugar >7.8 mmol/L (22/24), AAA size (P7.8 mmol/L (14/24), AAA size (P7.8 mmol/L (11/24), AAA size (PAAA therapy.

  17. Quantification of Microtexture at Weld Nugget of Friction Stir-Welded Carbon Steel

    Science.gov (United States)

    Husain, Md M.; Sarkar, R.; Pal, T. K.; Ghosh, M.; Prabhu, N.

    2017-05-01

    Friction stir welding of C-Mn steel was carried out under 800-1400 rpm tool rotation. Tool traversing speed of 50 mm/min remained same for all joints. Effect of thermal state and deformation on texture and microstructure at weld nugget was investigated. Weld nugget consisted of ferrite + bainite/Widmanstatten ferrite with different matrix grain sizes depending on peak temperature. A texture around ( ϕ 2 = 0°, φ = 30°, ϕ 2 = 45°) was developed at weld nugget. Grain boundary misorientation at weld nugget indicated that continuous dynamic recrystallization influenced the development of fine equiaxed grain structure. Pole figures and orientation distribution function were used to determine crystallographic texture at weld nugget and base metal. Shear texture components D1, D2 and F were present at weld nugget. D1 shear texture was more prominent among all. Large number of high-angle grain boundaries ( 60-70%) was observed at weld nugget and was the resultant of accumulation of high amount of dislocation, followed by subgrain formation.

  18. Nickel-base alloy overlay weld with improved ultrasonic flaw detection by magnetic stirring welding

    International Nuclear Information System (INIS)

    Takashi, Hirano; Kenji, Hirano; Masayuki, Watando; Takahiro, Arakawa; Minoru, Maeda

    2001-01-01

    Ultrasonic flaw detection is more difficult in Nickel-base alloy welds containing dendrites owing to the decrease ultrasonic transmissibility they cause. The present paper discusses application of magnetic stirring welding as a means for reducing dendrite growth with consequent improvement in ultrasonic transmissibility. Single pass and multi-pass welding tests were conducted to determine optimal welding conditions. By PT and macro observation subsequent to welding was carried out, optimal operation conditions were clarified. Overlay welding tests and UT clearly indicated ultrasonic beam transmissibility in overlay welds to be improved and detection capacity to be greater through application of magnetic stirring welding. Optimal operation conditions were determined based on examination of temper bead effects in the heat affected zone of low alloy steel by application of magnetic stirring welding to the butt welded joints between low alloy and stainless steel. Hardness in this zone of low alloy steel after the fourth layer was less than 350 HV. (author)

  19. Effect of weld spacing on microstructure and mechanical properties of CLAM electron beam welding joints

    Energy Technology Data Exchange (ETDEWEB)

    Zhai, Yutao; Huang, Bo, E-mail: aufa0007@163.com; Zhang, Junyu; Zhang, Baoren; Liu, Shaojun; Huang, Qunying

    2016-11-15

    Highlights: • The welded joints of CLAM steel with different weld spacings have been fabricated with electron beam welding, and a simplified model of CLAM sheet was proposed. • The microstructure and mechanical properties such as microhardness, impact and tensile were investigated at different welding spacing for both conditions of as-welded and post weld heat treatment (PWHT). • The effect of the welding thermal cycle was significantly when the weld spacings were smaller than 4 mm. • When the weld spacing was small enough, the original microstructures would be fragmented with the high heat input. - Abstract: China low activation martensitic (CLAM) steel has been chosen as the primary structural material in the designs of dual function lithium-lead (DFLL) blanket for fusion reactors, China helium cooled ceramic breeder (HCCB) test blanket module (TBM) for ITER and China fusion engineering test reactor (CFETR) blanket. The cooling components of the blankets are designed with high density cooling channels (HDCCs) to remove the high nuclear thermal effectively. Hence, the welding spacing among the channels are small. In this paper, the welded joints of CLAM steel with different weld spacings have been fabricated with electron beam welding (EBW). The weld spacing was designed to be 2 mm, 3 mm, 4 mm, 6 mm and 8 mm. The microstructure and mechanical properties such as microhardness, impact and tensile were investigated at different welding spacing for both conditions of as-welded and post weld heat treatment (PWHT). The PWHT is tempering at 740 °C for 120 min. The results showed that the grain size in the heat affected zone (HAZ) increased with the increasing weld spacing, and the joint with small weld spacing had a better performance after PWHT. This work would give useful guidance to improve the preparation of the cooling components of blanket.

  20. Capabilities of infrared weld monitor

    Energy Technology Data Exchange (ETDEWEB)

    Sanders, P.G.; Keske, J.S.; Leong, K.H.; Kornecki, G.

    1997-11-01

    A non-obtrusive pre-aligned, solid-state device has been developed to monitor the primary infrared emissions during laser welding. The weld monitor output is a 100-1000 mV signal that depends on the beam power and weld characteristics. The DC level of this signal is related to weld penetration, while AC portions of the output can be correlated with surface irregularities and part misalignment or contamination. Changes in DC behavior are also noted for both full and deep penetration welds. Full penetration welds are signified by an abrupt reduction in the weld monitor output. Bead on plate welds were made on steel, aluminum, and magnesium with both a CW CO{sub 2} laser and a pulsed Nd:YAG laser to explore the relationships between the weld characteristics and the weld monitor output.

  1. Endovascular Management of Iatrogenic Native Renal Arterial Pseudoaneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Sildiroglu, Onur; Saad, Wael E.; Hagspiel, Klaus D.; Matsumoto, Alan H.; Turba, Ulku Cenk, E-mail: Turba@me.com [University of Virginia Health System, Department of Radiology (United States)

    2012-12-15

    Purpose: Our purpose was to evaluate iatrogenic renal pseudoaneurysms, endovascular treatment, and outcomes. Methods: This retrospective study (2003-2011) reported the technical and clinical outcomes of endovascular therapy for renal pseudoaneurysms in eight patients (mean age, 46 (range 24-68) years). Renal parenchymal loss evaluation was based on digital subtraction angiography and computed tomography. Results: We identified eight iatrogenic renal pseudoaneurysm patients with symptoms of hematuria, pain, and hematoma after renal biopsy (n = 3), surgery (n = 3), percutaneous nephrolithotomy (n = 1), and endoscopic shock-wave lithotripsy (n = 1). In six patients, the pseudoaneurysms were small-sized (<20 mm) and peripherally located and were treated solely with coil embolization (n = 5). In one patient, coil embolization was preceded by embolization with 500-700 micron embospheres to control active bleeding. The remaining two patients had large-sized ({>=}50 mm), centrally located renal pseudoaneurysms treated with thrombin {+-} coils. Technical success with immediate bleeding cessation was achieved in all patients. There were no procedure-related deaths or complications (mean follow-up, 23.5 (range, 1-67) months). Conclusions: Treatment of renal pseudoaneurysms using endovascular approach is a relatively safe and viable option regardless of location (central or peripheral) and size of the lesions with minimal renal parenchymal sacrifice.

  2. Welding overlay analysis of dissimilar metal weld cracking of feedwater nozzle

    International Nuclear Information System (INIS)

    Tsai, Y.L.; Wang, Li. H.; Fan, T.W.; Ranganath, Sam; Wang, C.K.; Chou, C.P.

    2010-01-01

    Inspection of the weld between the feedwater nozzle and the safe end at one Taiwan BWR showed axial indications in the Alloy 182 weld. The indication was sufficiently deep that continued operation could not be justified considering the crack growth for one cycle. A weld overlay was decided to implement for restoring the structural margin. This study reviews the cracking cases of feedwater nozzle welds in other nuclear plants, and reports the lesson learned in the engineering project of this weld overlay repair. The overlay design, the FCG calculation and the stress analysis by FEM are presented to confirm that the Code Case structural margins are met. The evaluations of the effect of weld shrinkage on the attached feedwater piping are also included. A number of challenges encountered in the engineering and analysis period are proposed for future study.

  3. Multi-physics modeling and numerical simulation of weld pool in GTA welding

    International Nuclear Information System (INIS)

    Nguyen, Minh-Chien

    2015-01-01

    In this work, we develop a 3D physical and numerical model of the GTA (Gas Tungsten Arc) welding process in order to predict, for given welding parameters, useful quantities for the designer of welded assembly: weld bead shape, fluid flow in the weld pool as well as thermal distribution in the work piece. The model is developed in the Cast3M (http://www-cast3m.cea.fr/) finite element software and takes into account the main physical phenomena acting in the work piece and particularly in the weld pool, subject to source terms modeling the arc part of the welding process. A steady solution of this model is thought for and involves the coupling of the nonlinear thermohydraulics and electromagnetic equations together with the displacement of the deformable free surface of the weld pool. A first step in the development consisted in modeling the electromagnetic phenomena with two different numerical methods, in comparing the numerical results obtained with those of the literature and in quantifying the importance of the Lorentz force and the Joule effect compared to the other mechanical and thermal sources by computing power balances. Then, in order to assess the predictive capability of the model, simulations of various welding configurations are performed: variation in the chemical composition of the material, of the welding speed, of the prescribed arc pressure and of the welding positions, which is a focus of this work, are studied. A good agreement is obtained between the results of our model and other experimental and numerical results of the literature. Eventually, a model accounting for metal filling is proposed and its results are discussed. Thus, our complete model can be seen as a solid foundation towards future totally-coupled 3D welding models including the arc and it will be included in WPROCESS the in-house CEA software dedicated to the numerical simulation of welding. (author) [fr

  4. Detecting flaws in welds

    International Nuclear Information System (INIS)

    Woodacre, A.; Lawton, H.

    1979-01-01

    An apparatus and a method for detecting flaws in welds in a workpiece, the portion of the workpiece containing the weld is maintained at a constant temperature and the weld is scanned by an infra red detector. The weld is then scanned again with the workpiece in contact with a cooling probe to produce a steeper temperature gradient across the weld. Comparison of the signals produced by each scan reveals the existence of defects in the welds. The signals may be displayed on an oscilloscope and the display may be observed by a TV camera and recorded on videotape. (UK)

  5. Multipass autogenous electron beam welding

    International Nuclear Information System (INIS)

    Murphy, J.L.; Mustaleski, T.M. Jr.; Watson, L.C.

    1986-01-01

    A multipass, autogenous welding procedure was developed for 7.6 mm (0.3 in.) wall thickness Type 304L stainless steel cylinders. The joint geometry has a 1.5 mm (0.06 in.) root-face width and a rectangular stepped groove that is 0.762 mm (0.03 in.) wide at the top of the root face and extends 1.5 mm in height, terminating into a groove width of 1.27 mm which extends to the outside of the 1.27 mm high weld-boss. One weld pass is made on the root, three passes on the 0.762 mm wide groove and three passes to complete the weld. Multipass, autogenous, electron beam welds maintain the characteristic high depth-to-width ratios and low heat input of single-pass, electron beam welds. The increased part distortion (which is still much less than from arc processes) in multipass weldments is corrected by a preweld machined compensation. Mechanical properties of multipass welds compare well with single-pass welds. The yield strength of welds in aluminum alloy 5083 is approximately the same for single-pass or multipass electron beam and gas, metal-arc welds. The incidence and size of porosity is less in multipass electron beam welding of aluminum as compared to gas, metal-arc welds. The multipass, autogenous, electron beam welding method has proven to be a reliable way to make some difficult welds in multilayer parts or in an instance where inside part temperature or weld underbead must be controlled and weld discontinuities must be minimized

  6. Transdermal patches: history, development and pharmacology

    Science.gov (United States)

    Pastore, Michael N; Kalia, Yogeshvar N; Horstmann, Michael; Roberts, Michael S

    2015-01-01

    Transdermal patches are now widely used as cosmetic, topical and transdermal delivery systems. These patches represent a key outcome from the growth in skin science, technology and expertise developed through trial and error, clinical observation and evidence-based studies that date back to the first existing human records. This review begins with the earliest topical therapies and traces topical delivery to the present-day transdermal patches, describing along the way the initial trials, devices and drug delivery systems that underpin current transdermal patches and their actives. This is followed by consideration of the evolution in the various patch designs and their limitations as well as requirements for actives to be used for transdermal delivery. The properties of and issues associated with the use of currently marketed products, such as variability, safety and regulatory aspects, are then described. The review concludes by examining future prospects for transdermal patches and drug delivery systems, such as the combination of active delivery systems with patches, minimally invasive microneedle patches and cutaneous solutions, including metered-dose systems. PMID:25560046

  7. Method optimization of ocular patches

    Directory of Open Access Journals (Sweden)

    Kamalesh Upreti

    2012-01-01

    Full Text Available The intraocular patches were prepared using gelatin as the polymer. Ocular patch were prepared by solvent casting method. The patches were prepared for six formulations GP1, GP2, GP3, GP4, GP5 and GP6. Petri dishes were used for formulation of ocular patch. Gelatin was used as a polymer of choice. Glutaraldehyde used as cross linking agent and (DMSO dimethylsulfoxide used as solubility enhancer. The elasticity depends upon the concentration of gelatin. 400 mg amount of polymer i.e gelatin gave the required elasticity for the formulation.

  8. Influence of the arc plasma parameters on the weld pool profile in TIG welding

    Science.gov (United States)

    Toropchin, A.; Frolov, V.; Pipa, A. V.; Kozakov, R.; Uhrlandt, D.

    2014-11-01

    Magneto-hydrodynamic simulations of the arc and fluid simulations of the weld pool can be beneficial in the analysis and further development of arc welding processes and welding machines. However, the appropriate coupling of arc and weld pool simulations needs further improvement. The tungsten inert gas (TIG) welding process is investigated by simulations including the weld pool. Experiments with optical diagnostics are used for the validation. A coupled computational model of the arc and the weld pool is developed using the software ANSYS CFX. The weld pool model considers the forces acting on the motion of the melt inside and on the surface of the pool, such as Marangoni, drag, electromagnetic forces and buoyancy. The experimental work includes analysis of cross-sections of the workpieces, highspeed video images and spectroscopic measurements. Experiments and calculations have been performed for various currents, distances between electrode and workpiece and nozzle diameters. The studies show the significant impact of material properties like surface tension dependence on temperature as well as of the arc structure on the weld pool behaviour and finally the weld seam depth. The experimental weld pool profiles and plasma temperatures are in good agreement with computational results.

  9. Influence of the arc plasma parameters on the weld pool profile in TIG welding

    International Nuclear Information System (INIS)

    Toropchin, A; Frolov, V; Pipa, A V; Kozakov, R; Uhrlandt, D

    2014-01-01

    Magneto-hydrodynamic simulations of the arc and fluid simulations of the weld pool can be beneficial in the analysis and further development of arc welding processes and welding machines. However, the appropriate coupling of arc and weld pool simulations needs further improvement. The tungsten inert gas (TIG) welding process is investigated by simulations including the weld pool. Experiments with optical diagnostics are used for the validation. A coupled computational model of the arc and the weld pool is developed using the software ANSYS CFX. The weld pool model considers the forces acting on the motion of the melt inside and on the surface of the pool, such as Marangoni, drag, electromagnetic forces and buoyancy. The experimental work includes analysis of cross-sections of the workpieces, highspeed video images and spectroscopic measurements. Experiments and calculations have been performed for various currents, distances between electrode and workpiece and nozzle diameters. The studies show the significant impact of material properties like surface tension dependence on temperature as well as of the arc structure on the weld pool behaviour and finally the weld seam depth. The experimental weld pool profiles and plasma temperatures are in good agreement with computational results

  10. Numerical weld modeling - a method for calculating weld-induced residual stresses

    International Nuclear Information System (INIS)

    Fricke, S.; Keim, E.; Schmidt, J.

    2001-01-01

    In the past, weld-induced residual stresses caused damage to numerous (power) plant parts, components and systems (Erve, M., Wesseling, U., Kilian, R., Hardt, R., Bruemmer, G., Maier, V., Ilg, U., 1994. Cracking in Stabilized Austenitic Stainless Steel Piping of German Boiling Water Reactors - Characteristic Features and Root Causes. 20. MPA-Seminar 1994, vol. 2, paper 29, pp.29.1-29.21). In the case of BWR nuclear power plants, this damage can be caused by the mechanism of intergranular stress corrosion cracking in austenitic piping or the core shroud in the reactor pressure vessel and is triggered chiefly by weld-induced residual stresses. One solution of this problem that has been used in the past involves experimental measurements of residual stresses in conjunction with weld optimization testing. However, the experimental analysis of all relevant parameters is an extremely tedious process. Numerical simulation using the finite element method (FEM) not only supplements this method but, in view of modern computer capacities, is also an equally valid alternative in its own right. This paper will demonstrate that the technique developed for numerical simulation of the welding process has not only been properly verified and validated on austenitic pipe welds, but that it also permits making selective statements on improvements to the welding process. For instance, numerical simulation can provide information on the starting point of welding for every weld bead, the effect of interpass cooling as far as a possible sensitization of the heat affected zone (HAZ) is concerned, the effect of gap width on the resultant weld residual stresses, or the effect of the 'last pass heat sink welding' (welding of the final passes while simultaneously cooling the inner surface with water) producing compressive stresses in the root area of a circumferential weld in an austenitic pipe. The computer program FERESA (finite element residual stress analysis) was based on a commercially

  11. Automatic welding of fuel elements

    International Nuclear Information System (INIS)

    Briola, J.

    1958-01-01

    The welding process depends on the type of fuel element, the can material and the number of cartridges to be welded: - inert-gas welding (used for G2 and the 1. set of EL3), - inert atmosphere arc welding (used for welding uranium and zirconium), - electronic welding (used for the 2. set of EL3 and the tank of Proserpine). (author) [fr

  12. Vision-based weld pool boundary extraction and width measurement during keyhole fiber laser welding

    Science.gov (United States)

    Luo, Masiyang; Shin, Yung C.

    2015-01-01

    In keyhole fiber laser welding processes, the weld pool behavior is essential to determining welding quality. To better observe and control the welding process, the accurate extraction of the weld pool boundary as well as the width is required. This work presents a weld pool edge detection technique based on an off axial green illumination laser and a coaxial image capturing system that consists of a CMOS camera and optic filters. According to the difference of image quality, a complete developed edge detection algorithm is proposed based on the local maximum gradient of greyness searching approach and linear interpolation. The extracted weld pool geometry and the width are validated by the actual welding width measurement and predictions by a numerical multi-phase model.

  13. Automatic welding machine for piping

    International Nuclear Information System (INIS)

    Yoshida, Kazuhiro; Koyama, Takaichi; Iizuka, Tomio; Ito, Yoshitoshi; Takami, Katsumi.

    1978-01-01

    A remotely controlled automatic special welding machine for piping was developed. This machine is utilized for long distance pipe lines, chemical plants, thermal power generating plants and nuclear power plants effectively from the viewpoint of good quality control, reduction of labor and good controllability. The function of this welding machine is to inspect the shape and dimensions of edge preparation before welding work by the sense of touch, to detect the temperature of melt pool, inspect the bead form by the sense of touch, and check the welding state by ITV during welding work, and to grind the bead surface and inspect the weld metal by ultrasonic test automatically after welding work. The construction of this welding system, the main specification of the apparatus, the welding procedure in detail, the electrical source of this welding machine, the cooling system, the structure and handling of guide ring, the central control system and the operating characteristics are explained. The working procedure and the effect by using this welding machine, and the application to nuclear power plants and the other industrial field are outlined. The HIDIC 08 is used as the controlling computer. This welding machine is useful for welding SUS piping as well as carbon steel piping. (Nakai, Y.)

  14. Laser welding to expand the allowable gap in bore welding for ITER blanket hydraulic connection

    Energy Technology Data Exchange (ETDEWEB)

    Tanigawa, Hisashi, E-mail: tanigawa.hisashi@jaea.go.jp; Maruyama, Takahito; Noguchi, Yuto; Takeda, Nobukazu; Kakudate, Satoshi

    2015-10-15

    For application to bore welding of hydraulic connection in the ITER blanket module, laser welding presents the following benefits: low weld heat input is preferred for re-welding of the irradiated material. Its contactless process can intrinsically avoid a failure mode of the tool sticking on the weld. The exact requirements for pipe alignment were assessed in comparison with the assembly tolerance. The groove geometry was modified to expand the allowable initial gap. The groove was machined to be partially thick to obviate the filler wire. First, plates with partially thick grooves were welded to elucidate the preferred groove geometry and welding conditions. With the modified groove, the plates were welded for the initial gap of 1.0 mm. Then the groove geometry and welding conditions were adjusted based on results of pipe welding tests. By application of the additional 0.5-mm-thick and 2.5-mm-wide metal in the groove, pipes with an initial gap of 0.7 mm were welded successfully.

  15. Impact of Smartphone Applications on Timing of Endovascular Therapy for Ischemic Stroke: A Preliminary Study.

    Science.gov (United States)

    Alotaibi, Naif M; Sarzetto, Francesca; Guha, Daipayan; Lu, Michael; Bodo, Andre; Gupta, Shaurya; Dyer, Erin; Howard, Peter; da Costa, Leodante; Swartz, Richard H; Boyle, Karl; Nathens, Avery B; Yang, Victor X D

    2017-11-01

    The metrics of imaging-to-puncture and imaging-to-reperfusion were recently found to be associated with the clinical outcomes of endovascular thrombectomy for acute ischemic stroke. However, measures for improving workflow within hospitals to achieve better timing results are largely unexplored for endovascular therapy. The aim of this study was to examine our experience with a novel smartphone application developed in house to improve our timing metrics for endovascular treatment. We developed an encrypted smartphone application connecting all stroke team members to expedite conversations and to provide synchronized real-time updates on the time window from stroke onset to imaging and to puncture. The effects of the application on the timing of endovascular therapy were evaluated with a secondary analysis of our single-center cohort. Our primary outcome was imaging-to-puncture time. We assessed the outcomes with nonparametric tests of statistical significance. Forty-five patients met our criteria for analysis among 66 consecutive patients with acute ischemic stroke who received endovascular therapy at our institution. After the implementation of the smartphone application, imaging-to-puncture time was significantly reduced (preapplication median time, 127 minutes; postapplication time, 69 minutes; P smartphone applications may reduce treatment times for endovascular therapy in acute ischemic stroke. Further studies are needed to confirm our findings. Copyright © 2017. Published by Elsevier Inc.

  16. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    International Nuclear Information System (INIS)

    Mühlenbruch, Georg; Nikoubashman, Omid; Steffen, Björn; Dadak, Mete; Palmowski, Moritz; Wiesmann, Martin

    2013-01-01

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

  17. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    Energy Technology Data Exchange (ETDEWEB)

    Muehlenbruch, Georg, E-mail: gmuehlenbruch@ukaachen.de; Nikoubashman, Omid; Steffen, Bjoern; Dadak, Mete [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany); Palmowski, Moritz [RWTH Aachen University, Department of Nuclear Medicine, University Hospital (Germany); Wiesmann, Martin [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany)

    2013-02-15

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

  18. Determination of welding parameters for execution of weld overlayer on PWR nuclear reactor nozzles

    International Nuclear Information System (INIS)

    Ribeiro, Gabriela M.; Lima, Luciana I.; Quinan, Marco A.; Schvartzman, Monica M.

    2009-01-01

    In the PWR reactors, nickel based dissimilar welds have been presented susceptibilities the stress corrosion (S C). For the mitigation the problem a deposition of weld layers on the external surface of the nozzle is an alternative, viewing to provoke the compression of the region subjected to S C. This paper presents a preliminary study on the determination of welding parameters to obtain these welding overlayers. Welding depositions were performed on a test piece welded with nickel 182 alloy, simulating the conditions of a nozzle used in a PWR nuclear power plant. The welding process was the GTAW (Gas Tungsten Arc Welding), and a nickel 52 alloy as addition material. The overlayers were performed on the base metals, carbon steel an stainless steel, changing the welding parameters and verifying the the time of each weld filet. After that, the samples were micro structurally characterized. The macro structures and the microstructures obtained through optical microscopy and Vickers microhardness are presented. The preliminary results make evident the good weld quality. However, a small weld parameters influence used in the base material microstructure (carbon steel and stainless steel). The obtained results in this study will be used as reference in the construction of a mock up which will simulate all the conditions of a pressurizer nozzle of PWR reactor

  19. Grinding Parts For Automatic Welding

    Science.gov (United States)

    Burley, Richard K.; Hoult, William S.

    1989-01-01

    Rollers guide grinding tool along prospective welding path. Skatelike fixture holds rotary grinder or file for machining large-diameter rings or ring segments in preparation for welding. Operator grasps handles to push rolling fixture along part. Rollers maintain precise dimensional relationship so grinding wheel cuts precise depth. Fixture-mounted grinder machines surface to quality sufficient for automatic welding; manual welding with attendant variations and distortion not necessary. Developed to enable automatic welding of parts, manual welding of which resulted in weld bead permeated with microscopic fissures.

  20. Welding repair of a dissimilar weld and respective consequences for other German plants

    International Nuclear Information System (INIS)

    Brummer, G.; Dauwel, W.; Wesseling, U.; Ilg, U.; Lauer, P.; Widera, M.; Wachter, O.

    2002-01-01

    During a regular refueling outage in a German nuclear power plant in year 2000, additional non-destructive examinations have been performed on request of the Authority, to fulfill some recommendations of the independent experts with regard to the retrospective application of the Basic Safety Concept for the ferritic main coolant piping of this plant. During these inspections, indications were found in a dissimilar weld between one of the fifteen MCL (main coolant lines) nozzles and the ECC (emergency core cooling) system piping. By means of on-site metallography and laboratory investigations on three boat samples taken from this weld, it could be shown that the indications were due to hot cracking in the surface layer of the weld. In the course of these investigations, at three locations at the circumference of the weld, dis-bonding defects were found between the ferritic base metal of the nozzle and the austenitic weld butter, which has been applied to join the nozzle to the austenitic safe-end. According to the results of the extensive investigations, the dis-bonding occurred during the manufacturing process after stress-relief heat-treatment of the buttering during the welding of the austenitic safe-end to the butter material. There was no evidence for any crack growth during operation of the plant. Due to the large size of the boat-samples, a weld repair was mandatory. This repair has been performed using the so-called temper-bead technique as specified in the ASME Code, without subsequent stress relief heat treatment, using an advanced automatic orbital TIG welding process. The welding has been successfully performed without the need of further repair work. For those dissimilar welds, all other plants, except one, had used Inconel welding material for buttering the ferritic nozzle instead of stainless steel welding metal. For metallurgical reasons, dis-bonding along the fusion line for Inconel buttered dissimilar welds is unlikely to occur. Nevertheless all

  1. Patch photopatch test at Manipal

    Directory of Open Access Journals (Sweden)

    Panja Arindrajit

    1994-01-01

    Full Text Available Patch and photopatch testing was performed on 55 patients with history of photosensitivity using Scandanavian photo patch test antigens obtained from Chemotechnique Diagnostics AB Sweden. The commonest reactions were seen to perfume mix 4 (21.0%, PABA 3 (15.78%, promethazine hydrochloride 3 (15.78%, chlorpromazine hydrochloride 3 (15.78%, balsam of peru 2 (10.52%, usnic acid, hexachlorophane, musk ambrette and 6 methyl coumarin showed 1 positive reaction each (5.26% suggesting either phototoxicity or photo sensitization. Patch and photo patch test positive reaction suggesting allergic sensitisation was seen to balsam of peru 3 (23.0% perfume mix 3 (23.0% promethazine hydrochloride 2 (15.3% and PABA, 6 methyl coumarin, tribromosalicylanilide, atranorin and wood mix showed positive reaction in one case each (7.69%. We conclude that photoxic or photo allergic reaction is a problem in India and patch photo patch test should be performed in all cases of idiopathic light eruptions to rule out photo sensitisation and in cases where photo sensitivity of exogenous origin is suspected.

  2. EFFECTS OF ELECTRODE DEFORMATION OF RESISTANCE SPOT WELDING ON 304 AUSTENITIC STAINLESS STEEL WELD GEOMETRY

    Directory of Open Access Journals (Sweden)

    Nachimani Charde

    2012-12-01

    Full Text Available The resistance spot welding process is accomplished by forcing huge amounts of current flow from the upper electrode tip through the base metals to the lower electrode tip, or vice versa or in both directions. A weld joint is established between the metal sheets through fusion, resulting in a strong bond between the sheets without occupying additional space. The growth of the weld nugget (bond between sheets is therefore determined from the welding current density; sufficient time for current delivery; reasonable electrode pressing force; and the area provided for current delivery (electrode tip. The welding current and weld time control the root penetration, while the electrode pressing force and electrode tips successfully accomplish the connection during the welding process. Although the welding current and weld time cause the heat generation at the areas concerned (electrode tip area, the electrode tips’ diameter and electrode pressing forces also directly influence the welding process. In this research truncated-electrode deformation and mushrooming effects are observed, which result in the welded areas being inconsistent due to the expulsion. The copper to chromium ratio is varied from the tip to the end of the electrode whilst the welding process is repeated. The welding heat affects the electrode and the electrode itself influences the shape of the weld geometry.

  3. Research on the Effects of Technical Parameters on the Molding of the Weld by A-TIG Welding

    OpenAIRE

    Shi, Kai; Pan, Wu

    2012-01-01

    The effects of welding parameters on the molding of weld by A-TIG welding of a 4mm thickness mild steel plate is studied in the present paper. The results obtained show that: as welding current increases A-TIG welding penetration gets deeper than TIG welding; size and shape of HAZ has remarkable change; A-TIG welding has the narrower weld pool width than TIG welding.

  4. Electron beam welding

    International Nuclear Information System (INIS)

    Schwartz, M.M.

    1974-01-01

    Electron-beam equipment is considered along with fixed and mobile electron-beam guns, questions of weld environment, medium and nonvacuum welding, weld-joint designs, tooling, the economics of electron-beam job shops, aspects of safety, quality assurance, and repair. The application of the process in the case of individual materials is discussed, giving attention to aluminum, beryllium, copper, niobium, magnesium, molybdenum, tantalum, titanium, metal alloys, superalloys, and various types of steel. Mechanical-property test results are examined along with the areas of application of electron-beam welding

  5. Outcomes of Peripheral Endovascular Interventions Based on Hospital Volume: A Mini Review of Published Literature

    Directory of Open Access Journals (Sweden)

    Samir V Patel

    2016-01-01

    Full Text Available Previous literature showed hospital procedural volume is an independent predictor for outcomes of various cardiac procedures. However, very few studies shown similar results for peripheral endovascular interventions especially peripheral atherectomy. Here we are reviewing previously published articles to provide volume-outcome relationship for peripheral atherectomy and angioplasty with or without endovascular stenting. We found higher hospital volume significantly and independently lowers in-hospital mortality, amputation rates, peri-procedural complications, length and cost of hospitalization for peripheral endovascular interventions.

  6. Early experience of endovascular treatment of peripheral vascular disease

    International Nuclear Information System (INIS)

    Ashraf, T.; Yousuf, K.; Karim, M.T.

    2015-01-01

    Atherosclerotic peripheral arterial disease (PAD) is prevalent affecting up to 16% of the population aged 55 years or older. Endovascular intervention for the treatment of limb ischemia has become the first line therapy but in Pakistan it is in embryonic stage due to dearth of trained persons and dedicated centres. This study was conducted to evaluate procedural success and early outcome of endovascular treatment of peripheral vascular disease. Methods: A prospective single arm multicentre study was conducted at the National Institute of Cardiovascular Disease and National Medical Centre, Karachi, Pakistan from January 2013 to June 2014. A total of 25 patients were enrolled in the study that underwent endovascular treatment. Out of 25 patients 23 (92%) had critical limb ischemia (CLI) as per TASC II classification (A to D) and 2 (8%) had carotid lesion with history of TIA. Patients of acute limb ischemia and stroke were excluded. Ankle brachial index (ABI) was classified as normal (0.9-1.3), mild (0.7-0.9), moderate (0.4-0.69), severe (<0.4). Outcome was taken as immediate success and symptoms, amputation of limb among CLI patients and incidence of stroke in patients with carotid artery lesion at end of six months. Results: Among aortoiliac, femoropopliteal and tibioperoneal lesions, tibioperoneal lesions at six months were found to be more symptomatic 6 (86%) and amputation 4 (57%). Two carotid lesions at follow up were asymptomatic without stroke. Conclusion: Endovascular treatment of peripheral vascular lesions, i.e., aortoiliac, femoropopliteal tibioperoneal and carotid lesions were satisfactory in immediate outcome. Tibioperoneal lesions were more symptomatic and limb amputation at six months. (author)

  7. Recent developments in pipeline welding practice

    Energy Technology Data Exchange (ETDEWEB)

    1979-01-01

    Fourteen chapters are included: overview of pipeline welding systems and quality assurance, CRC automatic welding system, H.C. Price Co. automatic welding system, semi-automatic MIG-welding process, partial penetration welding of steel pipes for gas distribution, construction procedures and quality control in offshore pipeline construction, welding in repair and maintenance of gas transmission pipelines, British Gas studies of welding on pressurized gas transmission pipelines, hot tapping pipelines, underwater welding for offshore pipelines and associated equipment, radial friction welding, material composition vs weld properties, review of NDT of pipeline welds, and safety assurance in pipeline construction. A bibliography of approximately 150 references is included, arranged according to subject and year.

  8. X-ray radiography of Ti6Al4V welded by plasma tungsten arc (PTA) welding

    Energy Technology Data Exchange (ETDEWEB)

    Dikbas, Halil; Caligulu, Ugur; Taskin, Mustafa; Turkmen, Mustafa [Firat Univ., Elazig (Turkey). Metallurgy Dept.

    2013-03-01

    In this study, X-ray radiographic tests of Ti6Al4V alloys welded by plasma tungsten arc welding (PTA) were investigated. PTA welding experiments were carried out under argon shielding gas atmosphere, at 1400-1600 W and 1800 W welding powers as well as 1 m/min, 0.75 m/min, and 0.50 m/min welding speeds. After this process, radiography of the welded joints was performed by X-ray diffraction. The result of the radiographic tests indicated that by increasing welding power the widths of deep penetration increased in all specimens. On the contrary, increasing welding speeds decreases the widths deep penetration. The best properties of Ti6Al4V joints were observed for specimens welded at 1800 W welding power and at 0.50 m/min welding speed. (orig.)

  9. Effects of welding parameters on friction stir spot welding of high density polyethylene sheets

    International Nuclear Information System (INIS)

    Bilici, Mustafa Kemal; Yukler, Ahmet Irfan

    2012-01-01

    Graphical abstract: (a) Schematic illustration of the cross section of a friction stir spot weld and (b) Geometry of the weld bonded area, x: nugget thickness and y: the thickness of the upper sheet. Highlights: → Welding parameters affect the FSSW nugget formation and the strength of the joint. → Melting of polyethylene occurred in the vicinity of the tool pin. → The joint that fractures with a pull nugget failure mode has a higher strength. -- Abstract: Friction stir spot welding parameters affect the weld strength of thermoplastics, such as high density polyethylene (HDPE) sheets. The effects of the welding parameters on static strength of friction stir spot welds of high density polyethylene sheets were investigated. For maximizing the weld strength, the selection of welding parameters is very important. In lap-shear tests two fracture modes were observed; cross nugget failure and pull nugget failure. The tool rotational speed, tool plunge depth and dwell time were determined to be important in the joint formation and its strength. The joint which had a better strength fails with a pull nugget failure morphology. Weld cross section image analysis of the joints were done with a video spectral comparator. The plunge rate of the tool was determined to have a negligible effect on friction stir spot welding.

  10. Patch size has no effect on insect visitation rate per unit area in garden-scale flower patches

    Science.gov (United States)

    Garbuzov, Mihail; Madsen, Andy; Ratnieks, Francis L. W.

    2015-01-01

    Previous studies investigating the effect of flower patch size on insect flower visitation rate have compared relatively large patches (10-1000s m2) and have generally found a negative relationship per unit area or per flower. Here, we investigate the effects of patch size on insect visitation in patches of smaller area (range c. 0.1-3.1 m2), which are of particular relevance to ornamental flower beds in parks and gardens. We studied two common garden plant species in full bloom with 6 patch sizes each: borage (Borago officinalis) and lavender (Lavandula × intermedia 'Grosso'). We quantified flower visitation by insects by making repeated counts of the insects foraging at each patch. On borage, all insects were honey bees (Apis mellifera, n = 5506 counts). On lavender, insects (n = 737 counts) were bumble bees (Bombus spp., 76.9%), flies (Diptera, 22.4%), and butterflies (Lepidoptera, 0.7%). On both plant species we found positive linear effects of patch size on insect numbers. However, there was no effect of patch size on the number of insects per unit area or per flower and, on lavender, for all insects combined or only bumble bees. The results show that it is possible to make unbiased comparisons of the attractiveness of plant species or varieties to flower-visiting insects using patches of different size within the small scale range studied and make possible projects aimed at comparing ornamental plant varieties using existing garden flower patches of variable area.

  11. Highly Sensitive Reentrant Cavity-Microstrip Patch Antenna Integrated Wireless Passive Pressure Sensor for High Temperature Applications

    Directory of Open Access Journals (Sweden)

    Fei Lu

    2017-01-01

    Full Text Available A novel reentrant cavity-microstrip patch antenna integrated wireless passive pressure sensor was proposed in this paper for high temperature applications. The reentrant cavity was analyzed from aspects of distributed model and equivalent lumped circuit model, on the basis of which an optimal sensor structure integrated with a rectangular microstrip patch antenna was proposed to better transmit/receive wireless signals. In this paper, the proposed sensor was fabricated with high temperature resistant alumina ceramic and silver metalization with weld sealing, and it was measured in a hermetic metal tank with nitrogen pressure loading. It was verified that the sensor was highly sensitive, keeping stable performance up to 300 kPa with an average sensitivity of 981.8 kHz/kPa at temperature 25°C, while, for high temperature measurement, the sensor can operate properly under pressure of 60–120 kPa in the temperature range of 25–300°C with maximum pressure sensitivity of 179.2 kHz/kPa. In practical application, the proposed sensor is used in a method called table lookup with a maximum error of 5.78%.

  12. Development of a PROficiency-Based StePwise Endovascular Curricular Training (PROSPECT) Program.

    Science.gov (United States)

    Maertens, Heidi; Aggarwal, Rajesh; Desender, Liesbeth; Vermassen, Frank; Van Herzeele, Isabelle

    2016-01-01

    Focus on patient safety, work-hour limitations, and cost-effective education is putting pressure to improve curricula to acquire minimally invasive techniques during surgical training. This study aimed to design a structured training program for endovascular skills and validate its assessment methods. A PROficiency-based StePwise Endovascular Curricular Training (PROSPECT) program was developed, consisting of e-learning and hands-on simulation modules, focusing on iliac and superficial femoral artery atherosclerotic disease. Construct validity was investigated. Performances were assessed using multiple-choice questionnaires, valid simulation parameters, global rating scorings, and examiner checklists. Feasibility was assessed by passage of 2 final-year medical students through this PROSPECT program. Ghent University Hospital, a tertiary clinical care and academic center in Belgium with general surgery residency program. Senior-year medical students were recruited at Ghent University Hospital. Vascular surgeons were invited to participate during conferences and meetings if they had performed at least 100 endovascular procedures as the primary operator during the last 2 years. Overall, 29 medical students and 20 vascular surgeons participated. Vascular surgeons obtained higher multiple-choice questionnaire scores (median: 24.5-22.0 vs. 15.0-12.0; p train cognitive, technical, and nontechnical endovascular skills was developed. A structured, stepwise, proficiency-based valid endovascular program to train cognitive, technical, and human factor skills has been developed and proven to be feasible. A randomized controlled trial has been initiated to investigate its effect on performances in real life, patient outcomes, and cost-effectiveness. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  13. Welding problems in nuclear power engineering

    International Nuclear Information System (INIS)

    Zubchenko, A.S.

    1986-01-01

    The problems of welding industry in nuclear power plant engineering, mainly related to the improvement of molten bath protection, are considered. Development of new materials for welding electrodes, for cladding and welding fluxes, is pointed out. Production of the following equipment is brought to a commercial level: welding heads and welding machines for branch pipe welding, anticorrosion cladding, zonal thermal treatment, electron beam welding facilities for the welding and maintenance of turbineblades, equipment for nondestructive testing of welded joints

  14. Laser weld process monitoring and control using chromatic filtering of thermal radiation from a weld pool

    International Nuclear Information System (INIS)

    Kim, Cheol Jung; Kim, Min Suk; Baik, Sung Hoon; Chung, Chin Man

    2000-06-01

    The application of high power Nd: YAG lasers for precision welding in industry has been growing quite fast these days in diverse areas such as the automobile, the electronics and the aerospace industries. These diverse applications also require the new developments for the precise control and the reliable process monitoring. Due to the hostile environment in laser welding, a remote monitoring is required. The present development relates in general to weld process monitoring techniques, and more particularly to improved methods and apparatus for real-time monitoring of thermal radiation of a weld pool to monitor a size variation and a focus shift of the weld pool for weld process control, utilizing the chromatic aberration of focusing lens or lenses. The monitoring technique of the size variation and the focus shift of a weld pool is developed by using the chromatic filtering of the thermal radiation from a weld pool. The monitoring of weld pool size variation can also be used to monitor the weld depth in a laser welding. Furthermore, the monitoring of the size variation of a weld pool is independent of the focus shift of a weld pool and the monitoring of the focus shift of a weld pool is independent of the size variation of a weld pool

  15. Laser weld process monitoring and control using chromatic filtering of thermal radiation from a weld pool

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Cheol Jung; Kim, Min Suk; Baik, Sung Hoon; Chung, Chin Man

    2000-06-01

    The application of high power Nd: YAG lasers for precision welding in industry has been growing quite fast these days in diverse areas such as the automobile, the electronics and the aerospace industries. These diverse applications also require the new developments for the precise control and the reliable process monitoring. Due to the hostile environment in laser welding, a remote monitoring is required. The present development relates in general to weld process monitoring techniques, and more particularly to improved methods and apparatus for real-time monitoring of thermal radiation of a weld pool to monitor a size variation and a focus shift of the weld pool for weld process control, utilizing the chromatic aberration of focusing lens or lenses. The monitoring technique of the size variation and the focus shift of a weld pool is developed by using the chromatic filtering of the thermal radiation from a weld pool. The monitoring of weld pool size variation can also be used to monitor the weld depth in a laser welding. Furthermore, the monitoring of the size variation of a weld pool is independent of the focus shift of a weld pool and the monitoring of the focus shift of a weld pool is independent of the size variation of a weld pool.

  16. Analysis of weld-cracking and improvement of the weld-repair process of superplastic forming tools

    International Nuclear Information System (INIS)

    Duchosal, A.; Deschaux-Beaume, F.; Lours, P.; Haro, S.; Fras, G.

    2013-01-01

    Highlights: ► Characterisation of the microstructure of a heat-resistant austenitic cast steel. ► Failure analysis using in situ tensile tests and isothermal fatigue tests. ► Analyses of weld cracking mechanism during shielded metal arc welding process. ► Improvement of weld-repair method by re-melting of the base material surface with GTAW process. - Abstract: Superplastic forming (SPF) dies are generally made of using heat resistant cast steels, which are very sensitive to weld cracking. In order to improve the weld-repair process of such dies to prevent weld-cracking, the microstructure and the mechanical behaviour of a typical heat-resistant cast steel was first studied, using isothermal low-cycle fatigue tests and in situ tensile tests. The welding behaviour of such steel was also investigated, using a shielded metal arc welding (SMAW) process and welding conditions similar to those employed for weld repair industrial dies. The comparison of the aspect of weld-cracking with the fracture mechanisms observed at room temperature or during isothermal low-cycle fatigue tests suggests a similar brittle failure mechanism, due to the presence of large interdendritic carbides in the cast steel. The melting of the cast steel surface using a gas tungsten arc welding (GTAW) process allowed to refine the primary carbides, and then to reduce the weld-cracking sensitivity. The refining method with GTAW before welding has been successfully tested to weld-repair a sample representative of SPF dies, and is recommended for subsequent repairs of such dies

  17. Real weld geometry determining mechanical properties of high power laser welded medium plates

    Science.gov (United States)

    Liu, Sang; Mi, Gaoyang; Yan, Fei; Wang, Chunming; Li, Peigen

    2018-06-01

    Weld width is commonly used as one of main factors to assess joint performances in laser welding. However, it changes significantly through the thickness direction in conditions of medium or thick plates. In this study, high-power autogenous laser welding was conducted on 7 mm thickness 201 stainless steel to elucidate the factor of whole weld transverse shape critically affecting the mechanical properties with the aim of predicting the performance visually through the weld appearance. The results show that single variation of welding parameters could result in great changes of weld pool figures and subsequently weld transverse shapes. All the obtained welds are composed of austenite containing small amount of cellular dendritic δ-Ferrite. The 0.2% proof stresses of Nail- and Peanut-shaped joint reach 458 MPa and 454 MPa, 88.2% and 87.5% of the base material respectively, while that of Wedge-shaped joint only comes to 371 MPa, 71.5% of the base material. The deterioration effect is believed to be caused by the axial grain zone in the weld center. The fatigue strength of joint P is a bit lower than N, but much better than W. Significant deformation incompatibility through the whole thickness and microstructure resistance to crack initiation should be responsible for the poor performance of W-shaped joints.

  18. Endovascular Management of Vascular Injury during Transsphenoidal Surgery

    OpenAIRE

    Çinar, C.; Bozkaya, H.; Parildar, M.; Oran, I.

    2013-01-01

    Vascular injury is an unusual and serious complication of transsphenoidal surgery. We aimed to define the role of angiography and endovascular treatment in patients with vascular injuries occurring during transsphenoidal surgery.

  19. Tailoring weld geometry during keyhole mode laser welding using a genetic algorithm and a heat transfer model

    International Nuclear Information System (INIS)

    Rai, R; DebRoy, T

    2006-01-01

    Tailoring of weld attributes based on scientific principles remains an important goal in welding research. The current generation of unidirectional laser keyhole models cannot determine sets of welding variables that can lead to a particular weld attribute such as specific weld geometry. Here we show how a computational heat transfer model of keyhole mode laser welding can be restructured for systematic tailoring of weld attributes based on scientific principles. Furthermore, the model presented here can calculate multiple sets of laser welding variables, i.e. laser power, welding speed and beam defocus, with each set leading to the same weld pool geometry. Many sets of welding variables were obtained via a global search using a real number-based genetic algorithm, which was combined with a numerical heat transfer model of keyhole laser welding. The reliability of the numerical heat transfer calculations was significantly improved by optimizing values of the uncertain input parameters from a limited volume of experimental data. The computational procedure was applied to the keyhole mode laser welding of the 5182 Al-Mg alloy to calculate various sets of welding variables to achieve a specified weld geometry. The calculated welding parameter sets showed wide variations of the values of welding parameters, but each set resulted in a similar fusion zone geometry. The effectiveness of the computational procedure was examined by comparing the computed weld geometry for each set of welding parameters with the corresponding experimental geometry. The results provide hope that systematic tailoring of weld attributes via multiple pathways, each representing alternative welding parameter sets, is attainable based on scientific principles

  20. Weld defect identification in friction stir welding using power spectral density

    Science.gov (United States)

    Das, Bipul; Pal, Sukhomay; Bag, Swarup

    2018-04-01

    Power spectral density estimates are powerful in extraction of useful information retained in signal. In the current research work classical periodogram and Welch periodogram algorithms are used for the estimation of power spectral density for vertical force signal and transverse force signal acquired during friction stir welding process. The estimated spectral densities reveal notable insight in identification of defects in friction stir welded samples. It was observed that higher spectral density against each process signals is a key indication in identifying the presence of possible internal defects in the welded samples. The developed methodology can offer preliminary information regarding presence of internal defects in friction stir welded samples can be best accepted as first level of safeguard in monitoring the friction stir welding process.

  1. Residual stresses and their mechanisms of production at circumferential weld by heat-sink welding

    International Nuclear Information System (INIS)

    Ueda, Yukio; Nakacho, Keiji; Ohkubo, Katsumi; Shimizu, Tsubasa.

    1983-01-01

    In the previous report, the authors showed effectiveness of the heat-sink welding (water cooling) to accomplish this end by conducting theoretical analysis and an experiment on residual stresses in the 4B pipe of SUS 304 by the conventional welding and the heat-sink welding at a certain standard heat-input condition. In this research, different pipe sizes and varied heat-input are applied. The welding residual stresses by the conventional welding and the heat-sink welding are obtained by the theoretical analysis and their production mechanisms are clarified. Hence the influence of the above changes of conditions on effectiveness of the heat-sink welding is investigated. The main results are summarized as follow. (1) In case of this pipes such as 2B and 4B pipes, it is important to minimize heat-input per one pass (especially for latter half passes) in order to improve the effectiveness of the heat-sink welding. The effectiveness can be predicted either by theoretical analysis of the temperature distribution history with consideration of the characteristic of heat transfer under spray-watering or by experimental measurement. (2) In case of 24B pipes, thick pipes, it is desirable to minimize heat-input for the first half passes, by which the heat-sink welding becomes more effective. In addition, no matter whether the conventional welding or the heat-sink welding, it is important to prevent angular distorsion which produces tensile axial stresses on the inner surface of the pipe in the weld zone. Possible measures to meet these requirements are to apply restraining jigs, to minimize the section area of the groove (ex. application of the narrow gap arc welding), and to change continuous welding to skip one. (J.P.N.)

  2. Instructional Guidelines. Welding.

    Science.gov (United States)

    Fordyce, H. L.; Doshier, Dale

    Using the standards of the American Welding Society and the American Society of Mechanical Engineers, this welding instructional guidelines manual presents a course of study in accordance with the current practices in industry. Intended for use in welding programs now practiced within the Federal Prison System, the phases of the program are…

  3. Welding process

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    For the final chapter of this book, there is basic introduction on welding process. The good radiography must know somehow on welding process so that they can know what kind of welding that must rejected or not. All of the exposure technique that mention in earlier chapter almost applicable in this field because welding process is critical problem if there is no inspection will be done. So, for this chapter, all the discontinuity that usually appeared will be discussed and there is another discontinuity maybe not to important and do not give big impact if found it, do not described here. On top of that, the decision to accept or reject based on code, standard and specification that agreed by both to make sure that decision that agreed is corrected and more meaningful.

  4. Short vs prolonged dual antiplatelet treatment upon endovascular stenting of peripheral arteries

    Directory of Open Access Journals (Sweden)

    Kronlage M

    2017-10-01

    Full Text Available Mariya Kronlage,1 Maximilian Wassmann,1 Britta Vogel,1 Oliver J Müller,1 Erwin Blessing,2 Hugo Katus,1,3 Christian Erbel1 1Department of Cardiology, Angiology and Pneumology, University Hospital Heidelberg, Heidelberg, 2SRH Klinikum Karlsbad Langensteinbach, Karlsbad, 3DZHK German Center for Cardiovascular Research, Partner Site Heidelberg/Mannheim, Mannheim, Germany Introduction: Peripheral artery disease (PAD is a highly prevalent disorder with a substantial economical burden. Dual antiplatelet treatment (DAPT upon endovascular stenting to prevent acute thrombotic reocclusions is an universally accepted practice for postinterventional management of PAD patients. However, the optimal period of time for DAPT upon endovascular stenting is not known.Methods: In the current nonrandomized, retrospective monocentric study, we evaluated the duration of DAPT upon endovascular stenting. A total of 261 endovascular SFA and iliac stenting procedures were performed on 214 patients and these patients were subdivided into a short (4–6 weeks or a prolonged (8–12 weeks DAPT regime group. More than 65% of the patients included were male, approximately 35% were diabetic, and 61% had a history of smoking. Of all the patients, 90% exhibited a Rutherford stage 2–3, and approximately half of the patients had a moderate-to-severe calcified target lesion with a length of >13 cm. Major safety end points were defined as any bleeding, compartment syndrome, and ischemic events. In addition to this, patency, all-cause mortality, as well as amputation were followed up over a period of 12 months upon intervention.Results: Twelve months after endovascular stenting, primary patency in our cohort was comparable between the groups (83.94% short vs 79.8% long DAPT, P>0.05. Major bleeding occurred in 18 cases without any difference between the groups (P>0.05. In addition, during the 12-month follow-up, 6 (3.4% patients in the short and 3 (3.5% in the prolonged DAPT regime

  5. Laser bonding with ICG-infused chitosan patches: preliminary experiences in suine dura mater and vocal folds

    Science.gov (United States)

    Rossi, Francesca; Matteini, Paolo; Ratto, Fulvio; Pini, Roberto; Iacoangeli, Maurizio; Giannoni, Luca; Fortuna, Damiano; Di Cicco, Emiliano; Corbara, Sylwia; Dallari, Stefano

    2014-05-01

    Laser bonding is a promising minimally invasive approach, emerging as a valid alternative to conventional suturing techniques. It shows widely demonstrated advantages in wound treatment: immediate closuring effect, minimal inflammatory response and scar formation, reduced healing time. This laser based technique can overcome the difficulties in working through narrow surgical corridors (e.g. the modern "key-hole" surgery as well as the endoscopy setting) or in thin tissues that are impossible to treat with staples and/or stitches. We recently proposed the use of chitosan matrices, stained with conventional chromophores, to be used in laser bonding of vascular tissue. In this work we propose the same procedure to perform laser bonding of vocal folds and dura mater repair. Laser bonding of vocal folds is proposed to avoid the development of adhesions (synechiae), after conventional or CO2 laser surgery. Laser bonding application in neurosurgery is proposed for the treatment of dural defects being the Cerebro Spinal Fluid leaks still a major issue. Vocal folds and dura mater were harvested from 9-months old porks and used in the experimental sessions within 4 hours after sacrifice. In vocal folds treatment, an IdocyanineGreen-infused chitosan patch was applied onto the anterior commissure, while the dura mater was previously incised and then bonded. A diode laser emitting at 810 nm, equipped with a 600 μm diameter optical fiber was used to weld the patch onto the tissue, by delivering single laser spots to induce local patch/tissue adhesion. The result is an immediate adhesion of the patch to the tissue. Standard histology was performed, in order to study the induced photothermal effect at the bonding sites. This preliminary experimental activity shows the advantages of the proposed technique in respect to standard surgery: simplification of the procedure; decreased foreign-body reaction; reduced inflammatory response; reduced operating times and better handling in

  6. Welding quality evaluation of resistance spot welding using the time-varying inductive reactance signal

    Science.gov (United States)

    Zhang, Hongjie; Hou, Yanyan; Yang, Tao; Zhang, Qian; Zhao, Jian

    2018-05-01

    In the spot welding process, a high alternating current is applied, resulting in a time-varying electromagnetic field surrounding the welder. When measuring the welding voltage signal, the impedance of the measuring circuit consists of two parts: dynamic resistance relating to weld nugget nucleation event and inductive reactance caused by mutual inductance. The aim of this study is to develop a method to acquire the dynamic reactance signal and to discuss the possibility of using this signal to evaluate the weld quality. For this purpose, a series of experiments were carried out. The reactance signals under different welding conditions were compared and the results showed that the morphological feature of the reactance signal was closely related to the welding current and it was also significantly influenced by some abnormal welding conditions. Some features were extracted from the reactance signal and combined to construct weld nugget strength and diameter prediction models based on the radial basis function (RBF) neural network. In addition, several features were also used to monitor the expulsion in the welding process by using Fisher linear discriminant analysis. The results indicated that using the dynamic reactance signal to evaluate weld quality is possible and feasible.

  7. Large-scale binding ligand prediction by improved patch-based method Patch-Surfer2.0.

    Science.gov (United States)

    Zhu, Xiaolei; Xiong, Yi; Kihara, Daisuke

    2015-03-01

    Ligand binding is a key aspect of the function of many proteins. Thus, binding ligand prediction provides important insight in understanding the biological function of proteins. Binding ligand prediction is also useful for drug design and examining potential drug side effects. We present a computational method named Patch-Surfer2.0, which predicts binding ligands for a protein pocket. By representing and comparing pockets at the level of small local surface patches that characterize physicochemical properties of the local regions, the method can identify binding pockets of the same ligand even if they do not share globally similar shapes. Properties of local patches are represented by an efficient mathematical representation, 3D Zernike Descriptor. Patch-Surfer2.0 has significant technical improvements over our previous prototype, which includes a new feature that captures approximate patch position with a geodesic distance histogram. Moreover, we constructed a large comprehensive database of ligand binding pockets that will be searched against by a query. The benchmark shows better performance of Patch-Surfer2.0 over existing methods. http://kiharalab.org/patchsurfer2.0/ CONTACT: dkihara@purdue.edu Supplementary data are available at Bioinformatics online. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Influence of weld discontinuities on strain controlled fatigue behavior of 308 stainless steel weld metal

    International Nuclear Information System (INIS)

    Bhanu Sankara Rao, K.; Valsan, M.; Sandhya, R.; Mannan, S.L.; Rodriguez, P.

    1994-01-01

    Detailed investigations have been performed for assessing the importance of weld discontinuities in strain controlled low cycle fatigue (LCF) behavior of 308 stainless steel (SS) welds. The LCF behavior of 308 SS welds containing defects was compared with that of type 304 SS base material and 308 SS sound weld metal. Weld pads were prepared by shielded metal arc welding process. Porosity and slag inclusions were introduced deliberately into the weld metal by grossly exaggerating the conditions normally causing such defects. Total axial strain controlled LCF tests have been conducted in air at 823 K on type 304 SS base and 308 SS sound weld metal employing strain amplitudes in the range from ±0.25 to ±0.8 percent. A single strain amplitude of ±0.25 percent was used for all the tests conducted on weld samples containing defects. The results indicated that the base material undergoes cyclic hardening whereas sound and defective welds experience cyclic softening. Base metal showed higher fatigue life than sound weld metal at all strain amplitudes. The presence of porosity and slag inclusions in the weld metal led to significant reduction in life. Porosity on the specimen surface has been found to be particularly harmful and caused a reduction in life by a factor of seven relative to sound weld metal

  9. Development of resistance welding process. 6. Evaluation test of welding properties of martensitic ODS steel)

    International Nuclear Information System (INIS)

    Kono, Shusaku; Seki, Masayuki; Ishibashi, Fujio

    2003-05-01

    The welding condition and the heat-treatment condition were optimized to evaluate welding properties of the martensitic ODS steel cladding tube. The test pieces for evaluation of strength properties of the welded zone were produced by the optimized welding condition. In order to evaluate the strength of the welded zone, the internal creep rapture test, the single axis creep rapture test, the burst test and the tensile test were conducted. Following results were obtained in these tests. (1) Weld ability: An excellent welding characteristic was observed. The micro cracks, etc. were not served at the joint starting point. The joint starting points were connected uniformly with errors less than 0.05 mm. It is considered that an excellent welding characteristic was result of homogeneous micro structure of cladding material. (2) End plug material: In case of the material of end plug was martensitic ODS steel as same as that of cladding tube, the micro structure and the precipitation state carbide near the welded zone were found to be almost same as that of cladding tube. (3) Optimization of heat-treatment condition: The heat treatments of normalizing (1050degC) and tempering (780degC) were performed after welding and the micro structure near the welded zone was the isometric structure with low dislocation density, the precipitation state of carbide was uniform as same as that of cladding tube. These heat treatments can relax the residual stress accumulated when welding; it is considered that these heat treatments after welding are indispensable. (4) Strength of welded zone: The strength of the welded zone was found to be equal to that of cladding tube in all the strength tests. Therefore, it is concluded that the welding technology for the martensitic ODS steel is completed. (author)

  10. Welding method by remote handling

    International Nuclear Information System (INIS)

    Hashinokuchi, Minoru.

    1994-01-01

    Water is charged into a pit (or a water reservoir) and an article to be welded is placed on a support in the pit by remote handling. A steel plate is disposed so as to cover the article to be welded by remote handling. The welding device is positioned to the portion to be welded and fixed in a state where the article to be welded is shielded from radiation by water and the steel plate. Water in the pit is drained till the portion to be welded is exposed to the atmosphere. Then, welding is conducted. After completion of the welding, water is charged again to the pit and the welding device and fixing jigs are decomposed in a state where the article to be welded is shielded again from radiation by water and the steel plate. Subsequently, the steel plate is removed by remote handling. Then, the article to be welded is returned from the pit to a temporary placing pool by remote handling. This can reduce operator's exposure. Further, since the amount of the shielding materials can be minimized, the amount of radioactive wastes can be decreased. (I.N.)

  11. Weld pool boundary and weld bead shape reconstruction based on passive vision in P-GMAW

    Institute of Scientific and Technical Information of China (English)

    Yan Zhihong; Zhang Guangjun; Gao Hongming; Wu Lin

    2006-01-01

    A passive visual sensing system is established in this research, and clear weld pool images in pulsed gas metal arc welding ( P-GMA W) can be captured with this system. The three-dimensional weld pool geometry, especially the weld height,is not only a crucial factor in determining workpiece mechanical properties, but also an important parameter for reflecting the penetration. A new three-dimensional (3D) model is established to describe the weld pool geometry in P-GMAW. Then, a series of algorithms are developed to extract the model geometrical parameters from the weld pool images. Furthermore, the method to reconstruct the 3D shape of weld pool boundary and weld bead from the two-dimensional images is investigated.

  12. Welding Course Curriculum.

    Science.gov (United States)

    Genits, Joseph C.

    This guide is intended for use in helping students gain a fundamental background on the major aspects of the welding trade. The course emphasis is on mastery of the manipulative skills necessary to develop successful welding techniques and on acquisition of an understanding of the specialized tools and equipment used in welding. The first part…

  13. On post-weld heat treatment cracking in tig welded superalloy ATI 718Plus

    Science.gov (United States)

    Asala, G.; Ojo, O. A.

    The susceptibility of heat affected zone (HAZ) to cracking in Tungsten Inert Gas (TIG) welded Allvac 718Plus superalloy during post-weld heat treatment (PWHT) was studied. Contrary to the previously reported case of low heat input electron beam welded Allvac 718Plus, where HAZ cracking occurred during PWHT, the TIG welded alloy is crack-free after PWHT, notwithstanding the presence of similar micro-constituents that caused cracking in the low input weld. Accordingly, the formation of brittle HAZ intergranular micro-constituents may not be a sufficient factor to determine cracking propensity, the extent of heat input during welding may be another major factor that influences HAZ cracking during PWHT of the aerospace superalloy Allvac 718Plus.

  14. Welding for the CRBRP steam generators

    International Nuclear Information System (INIS)

    Spalaris, C.N.; Ring, P.J.; Durand, R.E.; Wright, E.A.

    1979-01-01

    The rationale for selecting weld design, welding procedures and inspection methods was based upon the desire to obtain the highest reliability welds for the CRBRP steam generators. To assure the highest weld reliability, heavy emphasis was placed on the control of material cleanliness and composition substantially exceeding the requirements of the ASME Code for 2-1/4Cr--1Mo. The high tube/tubesheet weld quality was achieved through close material control, an extensive weld development program and the selection of high reliability welding equipment. Shell and nozzle weld fabrication using TIG, MIG, and submerged arc procedures are also being controlled through precise specifications, including preheat and postheat programs, together with radiography and ultrasonic inspection to ascertain the weld quality desired. Details of the tube/tubesheet welding and shell welding are described and results from the weld testing program are discussed

  15. Performance of mesh seam welds in tailor welded blanks; Terado blank yo mash seam yosetsubu no tokusei

    Energy Technology Data Exchange (ETDEWEB)

    Uchihara, M; Takahashi, M; Kurita, M; Hirose, Y; Fukui, K [Sumitomo Metal Industries, Ltd., Osaka (Japan)

    1997-10-01

    Formability, fatigue properties and corrosion behavior of mash seam welded steel sheets were investigated and the results were compared with laser weld. The stretch formability of mash seam weld and laser weld were same level. Mash seam weld however, showed slightly smaller formability in hole expansion test. The fatigue strength of mash seam welds was lower than that of laser welds in case of differential thickness joints. Corrosion was apt to initiate at weld in both mash seam and laser weld with E-coat. The corrosion resistance of welds was improved by using zinc coated steel. 3 refs., 14 figs., 2 tabs.

  16. Biocide patch tests

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Veien, Niels

    1985-01-01

    Routine patch testing with a series of 6 industrial biocides containing methylene-bis-thiocyanate (Cytox 3522), benzisothiazolin-3-one (BIT), chlorocresol (Preventol CMK), 2-n-octyl-4-isothiazolin-3-one (Kathon 893), polyhydroxymethylene monobenzylether (Preventol D2) or 1,3,5-tris (hydroxy......-ethyl) hexahydrotriazine (Grotan BK) was carried out in 6 Danish out-patient clinics to evaluate guinea pig allergy test results with the same compounds. A total of 1652 consecutive patients with dermatitis were tested. The usefulness of this patch test battery was limited. There were a few positive reactions to Cytox...... of male patients and atopics, but significant differences in the frequencies of occupational cases, hand eczemas, and leg ulcers/stasis dermatitis, indicating possible variations in referral patterns, use of patch tests, and/or environmental factors....

  17. Resistance Spot Welding of dissimilar Steels

    Directory of Open Access Journals (Sweden)

    Ladislav Kolařík

    2012-01-01

    Full Text Available This paper presents an analysis of the properties of resistance spot welds between low carbon steel and austenitic CrNi stainless steel. The thickness of the welded dissimilar materials was 2 mm. A DeltaSpot welding gun with a process tape was used for welding the dissimilar steels. Resistance spot welds were produced with various welding parameters (welding currents ranging from 7 to 8 kA. Light microscopy, microhardness measurements across the welded joints, and EDX analysis were used to evaluate the quality of the resistance spot welds. The results confirm the applicability of DeltaSpot welding for this combination of materials.

  18. Nursing experience in clinical endovascular treatment for renal artery aneurysms

    International Nuclear Information System (INIS)

    Dong Yanfen; Pan Xiaoxia; Luan Shaoliang; Wei Ren

    2012-01-01

    Objective: To discuss the standardized clinical nursing measures for patients receiving endovascular treatment of renal artery aneurysms. Methods: The clinical data of 9 patients with renal artery aneurysm, who were admitted to authors' hospital during the period from Jan. 2010 to Aug. 2011 and received endovascular treatment, were retrospectively analyzed. The related nursing points as well as the received endovascular. Results: A total of 9 cases with renal artery aneurysm were treated nursing measures were summarized. Results: A total of 9 cases with renal artery aneurysm were with interventional management, including embolization (n = 6), stent implantation (n = 2) and stent implantation together with coil embolization (n = 1). The mean hospitalization time was (10±2) days. Postoperative retention of urine was observed in one patient and postoperative retroperitoneal hemorrhage occurred in another patient. Neither nursing-related nor operation-related complications occurred. Conclusion: Standardized perioperative nursing care for patients with renal artery aneurysm can surely help enhance the patient's tolerance to the surgery, and effectively prevent the complications. (authors)

  19. Using Taguchi method to optimize welding pool of dissimilar laser welded components

    OpenAIRE

    Anawa, E.; Olabi, Abdul-Ghani

    2008-01-01

    In the present work CO2 continuous laser welding process was successfully applied and optimized for joining a dissimilar AISI 316 stainless steel and AISI 1009 low carbon steel plates. Laser power, welding speed, and defocusing distance combinations were carefully selected with the objective of producing welded joint with complete penetration, minimum fusion zone size and acceptable welding profile. Fusion zone area and shape of dissimilar austenitic stainless steel with ferritic low carbon s...

  20. Welding, Bonding and Fastening, 1984

    Science.gov (United States)

    Buckley, J. D. (Editor); Stein, B. A. (Editor)

    1985-01-01

    A compilation of papers presented in a joint NASA, American Society for Metals, The George Washington University, American Welding Soceity, and Society of Manufacturing Engineers conference on Welding, Bonding, and Fastening at Langley Research Center, Hampton, VA, on October 23 to 25, 1984 is given. Papers were presented on technology developed in current research programs relevant to welding, bonding, and fastening of structural materials required in fabricating structures and mechanical systems used in the aerospace, hydrospace, and automotive industries. Topics covered in the conference included equipment, hardware and materials used when welding, brazing, and soldering, mechanical fastening, explosive welding, use of unique selected joining techniques, adhesives bonding, and nondestructive evaluation. A concept of the factory of the future was presented, followed by advanced welding techniques, automated equipment for welding, welding in a cryogenic atmosphere, blind fastening, stress corrosion resistant fasteners, fastening equipment, explosive welding of different configurations and materials, solid-state bonding, electron beam welding, new adhesives, effects of cryogenics on adhesives, and new techniques and equipment for adhesive bonding.

  1. Level of headaches after surgical aneurysm clipping decreases significantly faster compared to endovascular coiled patients

    Directory of Open Access Journals (Sweden)

    Athanasios K. Petridis

    2017-04-01

    Full Text Available In incidental aneurysms, endovascular treatment can lead to post-procedural headaches. We studied the difference of surgical clipping vs. endovascular coiling in concern to post-procedural headaches in patients with ruptured aneurysms. Sixtyseven patients with aneurysmal subarachnoidal haemorrhage were treated in our department from September 1st 2015 - September 1st 2016. 43 Patients were included in the study and the rest was excluded because of late recovery or highgrade subarachnoid bleedings. Twenty-two were surgical treated and twenty-one were interventionally treated. We compared the post-procedural headaches at the time points of 24 h, 21 days, and 3 months after treatment using the visual analog scale (VAS for pain. After surgical clipping the headache score decreased for 8.8 points in the VAS, whereas the endovascular treated population showed a decrease of headaches of 3.3 points. This difference was highly statistical significant and remained significant even after 3 weeks where the pain score for the surgically treated patients was 0.68 and for the endovascular treated 1.8. After 3 months the pain was less than 1 for both groups with surgically treated patients scoring 0.1 and endovascular treated patients 0.9 (not significant. Clipping is relieving the headaches of patients with aneurysm rupture faster and more effective than endovascular coiling. This effect stays significant for at least 3 weeks and plays a crucial role in stress relieve during the acute and subacute ICU care of such patients.

  2. Selected Welding Techniques, Part 2

    National Research Council Canada - National Science Library

    1964-01-01

    Partial contents: CONVENTIONAL WELD JOINTS VERSUS BUTT JOINTS IN 1-INCH ALUMINUM PLATE, SPECIAL WELD JOINT PREPARATION, UPSET METAL EDGES FOR INCREASED WELD JOINT STRENGTH, OUT-OF-POSITION WELDING OF HEAVY GAGE...

  3. Visuospatial and psychomotor aptitude predicts endovascular performance of inexperienced individuals on a virtual reality simulator.

    Science.gov (United States)

    Van Herzeele, Isabelle; O'Donoghue, Kevin G L; Aggarwal, Rajesh; Vermassen, Frank; Darzi, Ara; Cheshire, Nicholas J W

    2010-04-01

    This study evaluated virtual reality (VR) simulation for endovascular training of medical students to determine whether innate perceptual, visuospatial, and psychomotor aptitude (VSA) can predict initial and plateau phase of technical endovascular skills acquisition. Twenty medical students received didactic and endovascular training on a commercially available VR simulator. Each student treated a series of 10 identical noncomplex renal artery stenoses endovascularly. The simulator recorded performance data instantly and objectively. An experienced interventionalist rated the performance at the initial and final sessions using generic (out of 40) and procedure-specific (out of 30) rating scales. VSA were tested with fine motor dexterity (FMD, Perdue Pegboard), psychomotor ability (minimally invasive virtual reality surgical trainer [MIST-VR]), image recall (Rey-Osterrieth), and organizational aptitude (map-planning). VSA performance scores were correlated with the assessment parameters of endovascular skills at commencement and completion of training. Medical students exhibited statistically significant learning curves from the initial to the plateau performance for contrast usage (medians, 28 vs 17 mL, P dexterity as well as with image recall at end of the training period. In addition to current recruitment strategies, VSA may be a useful tool for predictive validity studies.

  4. Homogeneous weldings of copper

    International Nuclear Information System (INIS)

    Campurri, C.; Lopez, M.; Fernandez, R.; Osorio, V.

    1995-01-01

    This research explored the metallurgical and mechanical properties of arc welding of copper related with influence of Argon, Helium and mixtures of them. Copper plates of 6 mm thickness were welded with different mixtures of the mentioned gases. The radiography of welded specimens with 100% He and 100% Ar does not show show any porosity. On the other hand, the copper plates welded different gas mixtures presented uniform porosity in the welded zone. The metallographies show recrystallized grain in the heat affected zone, while the welding zone showed a dendritic structure. The results of the tensile strength vary between a maximum of 227 MPa for 100% He and a minimum of 174 MOa for the mixture of 60% He and 40% Ar. For the elongation after fracture the best values, about 36%, were obtained for pure gases. As a main conclusion, we can say that arc welding of copper is possible without loosing the mechanical and metallurgical properties of base metal. 6 refs

  5. Collection of analytes from microneedle patches.

    Science.gov (United States)

    Romanyuk, Andrey V; Zvezdin, Vasiliy N; Samant, Pradnya; Grenader, Mark I; Zemlyanova, Marina; Prausnitz, Mark R

    2014-11-04

    Clinical medicine and public health would benefit from simplified acquisition of biological samples from patients that can be easily obtained at point of care, in the field, and by patients themselves. Microneedle patches are designed to serve this need by collecting dermal interstitial fluid containing biomarkers without the dangers, pain, or expertise needed to collect blood. This study presents novel methods to collect biomarker analytes from microneedle patches for analysis by integration into conventional analytical laboratory microtubes and microplates. Microneedle patches were made out of cross-linked hydrogel composed of poly(methyl vinyl ether-alt-maleic acid) and poly(ethylene glycol) prepared by micromolding. Microneedle patches were shown to swell with water up to 50-fold in volume, depending on degree of polymer cross-linking, and to collect interstitial fluid from the skin of rats. To collect analytes from microneedle patches, the patches were mounted within the cap of microcentrifuge tubes or formed the top of V-bottom multiwell microplates, and fluid was collected in the bottom of the tubes under gentle centrifugation. In another method, microneedle patches were attached to form the bottom of multiwell microplates, thereby enabling in situ analysis. The simplicity of biological sample acquisition using microneedle patches coupled with the simplicity of analyte collection from microneedles patches integrated into conventional analytical equipment could broaden the reach of future screening, diagnosis, and monitoring of biomarkers in healthcare and environmental/workplace settings.

  6. Endovascular strategy for unruptured cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Mangiafico, S., E-mail: mangiax@libero.it [Interventional Neuroradiology Unit, Careggi University Hospital, Florence (Italy); Guarnieri, G., E-mail: gianluigiguarnieri@hotmail.it [Neuroradiology Service, Cardarelli Hospital, Naples (Italy); Consoli, A., E-mail: onemed21@gmail.com [Interventional Neuroradiology Unit, Careggi University Hospital, Florence (Italy); Ambrosanio, G., E-mail: gambros@libero.it [Neuroradiology Service, Cardarelli Hospital, Naples (Italy); Muto, M., E-mail: mutomar@tiscali.it [Neuroradiology Service, Cardarelli Hospital, Naples (Italy)

    2013-10-01

    The treatment of unruptured intracranial aneurysms (UIAs) remains complex and not clearly defined. While for ruptured intracranial aneurysms the management and the treatment option (surgery or endovascular treatment) are well defined by several trials, for asymptomatic UIAs the best management is still currently uncertain. The rationale to treat an UIA is to prevent the rupture and its consequent SAH and all complications derived from hemorrhage or reduce/eliminate neurological palsy. Although this statement is correct, the indication to treat an UIA should be based on a correct balance between the natural history of UIA and treatment risk. Patient's clinical history, aneurysm characteristics, and strategy management influence the natural history of UIAs and treatment outcomes. In the last 10 years and more, two important large multicenter studies were performed in order to analysis of all these factors and to evaluate the best treatment option for UIAs. The aim of this paper is to try to synthesize the possible indications to the endovascular treatment (EVT), when and how to treat an UIA.

  7. Optimization of process parameters in welding of dissimilar steels using robot TIG welding

    Science.gov (United States)

    Navaneeswar Reddy, G.; VenkataRamana, M.

    2018-03-01

    Robot TIG welding is a modern technique used for joining two work pieces with high precision. Design of Experiments is used to conduct experiments by varying weld parameters like current, wire feed and travelling speed. The welding parameters play important role in joining of dissimilar stainless steel SS 304L and SS430. In this work, influences of welding parameter on Robot TIG Welded specimens are investigated using Response Surface Methodology. The Micro Vickers hardness tests of the weldments are measured. The process parameters are optimized to maximize the hardness of the weldments.

  8. Influence of shielding gas pressure on welding characteristics in CO2 laser-MIG hybrid welding process

    Science.gov (United States)

    Chen, Yanbin; Lei, Zhenglong; Li, Liqun; Wu, Lin

    2006-01-01

    The droplet transfer behavior and weld characteristics have been investigated under different pressures of shielding gas in CO2 laser and metal inert/active gas (laser-MIG) hybrid welding process. The experimental results indicate that the inherent droplet transfer frequency and stable welding range of conventional MIG arc are changed due to the interaction between CO2 laser beam and MIG arc in laser-MIG hybrid welding process, and the shielding gas pressure has a crucial effect on welding characteristics. When the pressure of shielding gas is low in comparison with MIG welding, the frequency of droplet transfer decreases, and the droplet transfer becomes unstable in laser-MIG hybrid welding. So the penetration depth decreases, which shows the characteristic of unstable hybrid welding. However, when the pressure of shielding gas increases to a critical value, the hybrid welding characteristic is changed from unstable hybrid welding to stable hybrid welding, and the frequency of droplet transfer and the penetration depth increase significantly.

  9. Treatment of Endovascular Coil and Stent Migration Using the Merci Retriever: Report of Three Cases

    Directory of Open Access Journals (Sweden)

    David K. Kung

    2012-01-01

    Full Text Available Background. Coil and stent migration is a potentially catastrophic complication in endovascular neurosurgery, which may lead to cerebral thromboembolism. Techniques for removing migrated coil and stent are not well established. Methods and Results. We present three cases in which coil or stent migration occurred during endovascular embolization of a cerebral aneurysm. The Merci Retrievers were used successfully in all cases to remove the displaced foreign bodies. Technical details are described. Conclusion. The Merci Retriever device can be utilized successfully for removal of migrated coils and stents in endovascular neurosurgery.

  10. Welding technologies for nuclear machinery and equipment

    International Nuclear Information System (INIS)

    Kobayashi, Masahiro; Yokono, Tomomi.

    1991-01-01

    The main welding methods applied to nuclear machinery and equipment are shielded metal arc welding, submerged arc welding, MAG welding and TIG welding. But in the last 10 years, in order to improve the reliability required for the welding of nuclear machinery and equipment, the welding technologies aiming at the reduction of heat input, the decrease of the number of welding pass and the automatic control of welding factors have been applied for the main purpose of bettering the quality and excluding human errors. The merits and the technology of narrow gap, pulsed MAG welding and melt-through welding are explained. As the automation of TIG welding, image processing type narrow gap, hot wire TIG welding and remote control type automatic TIG welding are described. For the longitudinal welding of active metal sheet products, plasma key-hole welding is applied. Since the concentration of its arc is good, high speed welding with low heat input can be done. For the stainless steel cladding by welding, electroslag welding has become to be employed in place of conventional submerged arc welding. Arc is not generated in the electroslag welding, and the penetration into base metal is small. (K.I.)

  11. Ultrasonic inspection of austenitic welds

    International Nuclear Information System (INIS)

    Baikie, B.L.; Wagg, A.R.; Whittle, M.J.; Yapp, D.

    1976-01-01

    The ultrasonic examination of austenitic stainless steel weld metal has always been regarded as a difficult proposition because of the large and variable ultrasonic attenuations and back scattering obtained from apparently similar weld deposits. The work to be described shows how the existence of a fibre texture within each weld deposit (as a result of epitaxial growth through successive weld beads) produces a systematic variation in the ultrasonic attenuation coefficient and the velocity of sound, depending upon the angle between the ultrasonic beam and the fibre axis. Development work has shown that it is possible to adjust the welding parameters to ensure that the crystallographic texture within each weld is compatible with improved ultrasonic transmission. The application of the results to the inspection of a specific weld in type 316 weld metal is described

  12. Endovascular treatment of posterior cerebral artery aneurysms using detachable coils

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Hong Gee [Kangwon National University Hospital, Department of Radiology, Chuncheon, Kangwon-do (Korea); Konkuk University Hospital, Department of Radiology, Seoul (Korea); Kim, Sam Soo; Han, Heon [Kangwon National University Hospital, Department of Radiology, Chuncheon, Kangwon-do (Korea); Kang, Hyun-Seung [Konkuk University Hospital, Department of Neurosurgery, Seoul (Korea); Moon, Won-Jin [Konkuk University Hospital, Department of Radiology, Seoul (Korea); Byun, Hong Sik [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea)

    2008-03-15

    Aneurysms of the posterior cerebral artery (PCA) are rare, and most of the studies reported in the literature in which the endovascular approach was applied were carried out on a limited number of patients with PCA aneurysms. We retrospectively reviewed our cases of PCA aneurysms - at various locations and of differing shapes - that received endovascular treatment and evaluated the treatment outcome. From January 1996 to December 2006, 13 patients (eight females and five males) with 17 PCA aneurysms (nine fusiform and eight saccular) were treated using the endovascular approach. The age of the patients ranged from 20 to 67 years, with a mean age of 44 years. Of the 13 patients, ten presented with intracranial hemorrhage, and one patient, with a large P2 aneurysm, presented with trigeminal neuralgia; the aneurysms were asymptomatic in the remaining two patients. All 13 patients were successfully treated, with only one procedure-related symptomatic complication. Seven patients were treated by occlusion of the aneurysm and parent artery together; five patients, by selective embolization of the aneurysm; one patient, by partial coiling. Although infarctions were found in two patients treated with selective embolization and in three patients treated with parent artery occlusion, only one patient with a ruptured P2 aneurysm treated with parent artery occlusion developed transient amnesia as an ischemic symptom. Posterior cerebral artery aneurysms can be treated safely with either occlusion of the aneurysm together with the PCA or with a selective coil embolization. Infarctions may occur after endovascular treatment, but they are rarely the cause of a disabling symptom. (orig.)

  13. Electron beam welding of aluminium components

    International Nuclear Information System (INIS)

    Maajid, Ali; Vadali, S.K.; Maury, D.K.

    2015-01-01

    Aluminium is one of the most widely used materials in industries like transportation, shipbuilding, manufacturing, aerospace, nuclear, etc. The challenges in joining of aluminium are distortion, cleanliness and quality. Main difficulties faced during fusion welding of aluminium components are removal of surface oxide layer, weld porosity, high heat input requirement, distortion, hot cracking, etc. Physical properties of aluminium such as its high thermal conductivity, high coefficient of thermal expansion, no change in colour at high temperature, large difference in the melting points of the metal and its oxide (∼ 1400 °C) compound the difficulties faced during welding. Gas Tungsten Arc Welding (GTAW), Gas Metal Arc Welding (GMAW), Plasma Arc Welding (PAW), etc are generally used in industries for fusion welding of aluminium alloys. However in case of thicker jobs the above processes are not suitable due to requirements of elaborate edge preparation, preheating of jobs, fixturing to prevent distortion, etc. Moreover, precise control over the heat input during welding and weld bead penetration is not possible with above processes. Further, if heat sensitive parts are located near the weld joint then high energy density beam welding process like Electron Beam Welding (EBW) is the best possible choice for aluminium welding.This paper discusses EB welding of aluminium components, typical geometry of components, selection/optimization of welding parameters, problems faced during standardization of welding and process parameters and their remedies etc.

  14. Edge of polar cap patches

    Science.gov (United States)

    Hosokawa, K.; Taguchi, S.; Ogawa, Y.

    2016-04-01

    On the night of 4 December 2013, a sequence of polar cap patches was captured by an all-sky airglow imager (ASI) in Longyearbyen, Norway (78.1°N, 15.5°E). The 630.0 nm airglow images from the ASI of 4 second exposure time, oversampled the emission of natural lifetime (with quenching) of at least ˜30 sec, introduce no observational blurring effects. By using such high-quality ASI images, we succeeded in visualizing an asymmetry in the gradients between the leading/trailing edges of the patches in a 2-D fashion. The gradient in the leading edge was found to be 2-3 times steeper than that in the trailing edge. We also identified fingerlike structures, appearing only along the trailing edge of the patches, whose horizontal scale size ranged from 55 to 210 km. These fingers are considered to be manifestations of plasma structuring through the gradient-drift instability (GDI), which is known to occur only along the trailing edge of patches. That is, the current 2-D observations visualized, for the first time, how GDI stirs the patch plasma and such a mixing process makes the trailing edge more gradual. This result strongly implies a close connection between the GDI-driven plasma stirring and the asymmetry in the large-scale shape of patches and then suggests that the fingerlike structures can be used as markers to estimate the fine-scale structure in the plasma flow within patches.

  15. Waste canister closure welding using the inertia friction welding process

    International Nuclear Information System (INIS)

    Klein, R.F.; Siemens, D.H.; Kuruzar, D.L.

    1986-02-01

    Liquid radioactive waste presently stored in underground tanks is to undergo a vitrifying process which will immobilize it in a solid form. This solid waste will be contained in a stainless steel canister. The canister opening requires a positive seal weld, the properties and thickness of which are at least equal to those of the canister material. This paper describes the inertia friction welding process and a proposed equipment design concept that will provide a positive, reliable, inspectable, and full thickness seal weld while providing easily maintainable equipment, even though the weld is made in a highly contaminated hot cell. All studies and tests performed have shown the concept to be highly feasible. 2 refs., 6 figs

  16. Endovascular treatment of penetrating arterial trauma with stent grafts.

    Science.gov (United States)

    Biagioni, Rodrigo Bruno; Burihan, Marcelo Calil; Nasser, Felipe; Biagioni, Luisa Ciucci; Ingrund, José Carlos

    2018-02-01

    The endovascular management of arterial injuries has resulted in reduced operating time, blood loss, hospital mortality, lower incidence of sepsis, and decrease in mortality rates. For penetrating trauma, however, the benefits of endovascular therapy are questionable. Data were obtained by retrospective analysis of electronic medical records. All patients with vascular trauma seeking care at our institution from January 2010 to December 2015 were reviewed. A total of 223 vascular trauma patients were enrolled. Of these, 18 patients (8 %) were treated with endovascular techniques. The data related to clinical presentation, patient characteristics, technical aspects of the treatment, and follow-up were analysed. The mean patient age was 35.4 ± 17.8 years, 94 % were male. The mean injury severity score was 10.4 ± 2.5. The most commonly observed trauma mechanism was a gunshot in 10 cases (55 %), followed by lesions provoked by arterial catheter misplacement in five cases (27 %), and stab wounds in three cases (16.6 %). The main injury site was the subclavian artery, accounting for eight cases (44 %), followed by the superficial femoral artery and the tibiofibular trunk in two cases, respectively (18 %). The anterior tibial, fibular artery, axillary, common carotid, superior mesenteric, and profunda femoris were each affected once. Arteriovenous fistula was detected in nine cases (50 %), pseudoaneurysms in nine cases (50 %), and short occlusion in two cases (11 %). The mean follow-up duration was 753 days. The primary patency rate was 92.3 and 61.5 % after one and two years, respectively. The survival rate was 94.4 % after one and two years. Infection of the stents or limb amputations were not identified at follow-up. The endovascular treatment of penetrating arterial injuries with covered stents is feasible. However, the criteria used to choose the best method must be individualized.

  17. Advances in endovascular therapy for ischemic cerebrovascular diseases

    Directory of Open Access Journals (Sweden)

    Jun Lu

    2016-09-01

    Full Text Available Endovascular therapy for ischemic cerebrovascular diseases has developed rapidly in recent years. The latest clinical trials of acute ischemic stroke have shown promising results with the continued advancement of concepts, techniques, and materials. Mechanical thrombectomy is recommended in the treatment of acute ischemic stroke caused by large vessel occlusion of the anterior circulation, according to the guidelines updated in Europe, USA, and China. The long-term therapeutic efficacy of endovascular stenting for carotid artery stenosis has also been proved noninferior to that of carotid endarterectomy. However, the latest clinical trials have shown that the efficacy of stenting for intracranial artery and vertebral artery stenosis is inferior to that of medical treatment alone, which needs urgent attention through further development and studies. Keywords: Ischemic cerebrovascular diseases, Interventional surgery, Progress

  18. Spot weld arrangement effects on the fatigue behavior of multi-spot welded joints

    International Nuclear Information System (INIS)

    Hassanifard, Soran; Zehsaz, Mohammad; Esmaeili, Firooz

    2011-01-01

    In the present study, the effects of spot weld arrangements in multi-spot welded joints on the fatigue behavior of the joints are studied. Three different four-spot welded joints are considered: one-row four-spot parallel to the loading direction, one-row four-spot perpendicular to the loading direction and two-row four-spot weld specimens. The experimental fatigue test results reveal that the differences between the fatigue lives of three spot welded types in the low cycle regime are more considerable than those in the high cycle regime. However, all kinds of spot weld specimens have similar fatigue strength when approaching a million cycles. A non-linear finite element analysis is performed to obtain the relative stress gradients, effective distances and notch strength reduction factors based on the volumetric approach. The work here shows that the volumetric approach does a very good job in predicting the fatigue life of the multi-spot welded joints

  19. Safety of low-dose aspirin in endovascular treatment for intracranial atherosclerotic stenosis.

    Directory of Open Access Journals (Sweden)

    Ning Ma

    Full Text Available OBJECTIVES: To evaluate the safety of low-dose aspirin plus clopidogrel versus high-dose aspirin plus clopidogrel in prevention of vascular risk within 90 days of duration of dual antiplatelet therapy in patients treated with intracranial endovascular treatment. METHODS: From January 2012 to December 2013, this prospective and observational study enrolled 370 patients with symptomatic intracranial atherosclerotic stenosis of ≥70% with poor collateral undergoing intracranial endovascular treatment. Antiplatelet therapy consists of aspirin, at a low-dose of 100 mg or high-dose of 300 mg daily; clopidogrel, at a dose of 75 mg daily for 5 days before endovascular treatment. The dual antiplatelet therapy continued for 90 days after intervention. The study endpoints include acute thrombosis, subacute thrombosis, stroke or death within 90 days after intervention. RESULTS: Two hundred and seventy three patients received low-dose aspirin plus clopidogrel and 97 patients received high-dose aspirin plus clopidogrel before intracranial endovascular treatment. Within 90 days after intervention, there were 4 patients (1.5% with acute thrombosis, 5 patients (1.8% with subacute thrombosis, 17 patients (6.2% with stroke, and 2 death (0.7% in low-dose aspirin group, compared with no patient (0% with acute thrombosis, 2 patient (2.1% with subacute thrombosis, 6 patients (6.2% with stroke, and 2 death (2.1% in high-dose aspirin group, and there were no significant difference in all study endpoints between two groups. CONCLUSION: Low-dose aspirin plus clopidogrel is comparative in safety with high-dose aspirin plus clopidogrel within 90 days of duration of dual antiplatelet therapy in patients treated with intracranial endovascular treatment.

  20. Percutaneous Endovascular Radiofrequency Ablation for Malignant Portal Obstruction: An Initial Clinical Experience

    International Nuclear Information System (INIS)

    Wu, Tian-Tian; Li, Hu-Cheng; Zheng, Fang; Ao, Guo-Kun; Lin, Hu; Li, Wei-Min

    2016-01-01

    PurposeThe Habib™ VesOpen Catheter is a new endovascular radiofrequency ablation (RFA) device used to treat malignant portal obstruction. The purpose of this study was to evaluate the clinical feasibility and safety of RFA with this device.MethodsWe collected the clinical records and follow-up data of patients with malignant portal obstruction treated with percutaneous endovascular portal RFA using the Habib™ VesOpen Catheter. Procedure-related complications, improvement of symptoms, portal patency, survival, and postoperative biochemical tests were investigated.ResultsThe 31 patients enrolled in the study underwent 41 successful endovascular portal RFA procedures. Patients were divided into a portal-stenting (PS) group (n = 13), which underwent subsequent portal stenting with self-expandable metallic stents, and a non-stenting (NS) group (n = 18), which did not undergo stenting. No procedure-related abdominal hemorrhage or portal rupture occurred. Postablation complications included abdominal pain (n = 26), fever (n = 13), and pleural effusion (n = 15). Improvements in clinical manifestations were observed in 27 of the 31 patients. Of the 17 patients experiencing portal restenosis, 10 underwent successful repeat RFA. The rate of successful repeat RFA was significantly higher in the NS group than in the PS group. Median portal patency was shorter in the PS group than in the NS group. No mortality occurred during the 4 weeks after percutaneous endovascular portal RFA.ConclusionsPercutaneous endovascular portal RFA is a feasible and safe therapeutic option for malignant portal obstruction. Prospective investigations should be performed to evaluate clinical efficacy, in particular, the need to evaluate the necessity for subsequent portal stenting.

  1. Percutaneous Endovascular Radiofrequency Ablation for Malignant Portal Obstruction: An Initial Clinical Experience

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Tian-Tian, E-mail: matthewwu1979@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China); Li, Hu-Cheng, E-mail: hucheng-li-surgery@126.com [The 307th Hospital of PLA, General Surgery Department (China); Zheng, Fang, E-mail: fang-zheng-surgery@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China); Ao, Guo-Kun, E-mail: guokun-ao-radiology@126.com; Lin, Hu, E-mail: hu-lin-radiology@126.com [The 309th Hospital of PLA, Radiology Department (China); Li, Wei-Min, E-mail: weimin-li-surgery@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China)

    2016-07-15

    PurposeThe Habib™ VesOpen Catheter is a new endovascular radiofrequency ablation (RFA) device used to treat malignant portal obstruction. The purpose of this study was to evaluate the clinical feasibility and safety of RFA with this device.MethodsWe collected the clinical records and follow-up data of patients with malignant portal obstruction treated with percutaneous endovascular portal RFA using the Habib™ VesOpen Catheter. Procedure-related complications, improvement of symptoms, portal patency, survival, and postoperative biochemical tests were investigated.ResultsThe 31 patients enrolled in the study underwent 41 successful endovascular portal RFA procedures. Patients were divided into a portal-stenting (PS) group (n = 13), which underwent subsequent portal stenting with self-expandable metallic stents, and a non-stenting (NS) group (n = 18), which did not undergo stenting. No procedure-related abdominal hemorrhage or portal rupture occurred. Postablation complications included abdominal pain (n = 26), fever (n = 13), and pleural effusion (n = 15). Improvements in clinical manifestations were observed in 27 of the 31 patients. Of the 17 patients experiencing portal restenosis, 10 underwent successful repeat RFA. The rate of successful repeat RFA was significantly higher in the NS group than in the PS group. Median portal patency was shorter in the PS group than in the NS group. No mortality occurred during the 4 weeks after percutaneous endovascular portal RFA.ConclusionsPercutaneous endovascular portal RFA is a feasible and safe therapeutic option for malignant portal obstruction. Prospective investigations should be performed to evaluate clinical efficacy, in particular, the need to evaluate the necessity for subsequent portal stenting.

  2. Investigate The Effect Of Welding Parameters On Mechanical Properties During The Welding Of Al-6061 Alloy

    Directory of Open Access Journals (Sweden)

    Rajendra Prasad

    2017-10-01

    Full Text Available Friction welding is a solid state welding technique which is being used in recent times to weld similar as well as dissimilar metals for getting defect free weld. Many combinations like low carbon to stainless steel austenitic to ferrite stainless steel aluminium to copper and titanium to aluminium or steel have been tried out by various solid state welding processes with quite good results. In the present work the 3 level full factorial design has been employed to investigate the effect of welding parameters on tensile strength toughness and heat generation during the welding of Al-6061 alloy. Mathematical relationships between friction welding parameters and mechanical properties like heat generation tensile strength and toughness have also been developed. An attempt has also been made to examine the fracture surfaces of test specimens using SEM. It has been found that welding speed is the most significant parameter thats affect the heat generation tensile strength and toughness. it has been found that tensile strength and toughness during welding increases with increased in welding speed while tensile strength and toughness initially increased as the welding time increases after that it decreased with increase in welding time. The difference in weight of alloying elements can be clearly seen by analyzing spectrum of elements.

  3. Endovascular Treatment of an Aortobronchial Fistula

    International Nuclear Information System (INIS)

    Numan, Fueruezan; Arbatli, Harun; Yagan, Naci; Demirsoy, Ergun; Soenmez, Binguer

    2004-01-01

    A 67-year-old man operated on 8 years previously for type B aortic dissection presented with two episodes of massive hemoptysis. An aortobronchial fistula was suspected with spiral computed tomography angiography, and showed a small pseudoaneurysm corresponding to the distal anastomotic site. The patient underwent endovascular stent-graft implantation and is asymptomatic 8 months after the procedure

  4. Aneurysm growth after late conversion of thoracic endovascular aortic repair

    Directory of Open Access Journals (Sweden)

    Hirofumi Kasahara

    2015-01-01

    Full Text Available A 69-year-old man underwent thoracic endovascular aortic repair of a descending aortic aneurysm. Three years later, he developed impending rupture due to aneurysmal expansion that included the proximal landing zone. Urgent open surgery was performed via lateral thoracotomy, and a Dacron graft was sewn to the previous stent graft distally with Teflon felt reinforcement. Postoperatively, four sequential computed tomography scans demonstrated that the aneurysm was additionally increasing in size probably due to continuous hematoma production, suggesting a possibility of endoleaks. This case demonstrates the importance of careful radiologic surveillance after endovascular repair, and also after partial open conversion.

  5. Salvage of bilateral renal artery occlusion after endovascular aneurysm repair with open splenorenal bypass

    Directory of Open Access Journals (Sweden)

    Samuel Jessula, MDCM

    2017-09-01

    Full Text Available We report renal salvage maneuvers after accidental bilateral renal artery coverage during endovascular aneurysm repair of an infrarenal abdominal aortic aneurysm. A 79-year-old man with an infrarenal abdominal aortic aneurysm was treated with endovascular aneurysm repair. Completion angiography demonstrated coverage of the renal arteries. Several revascularization techniques were attempted, including endograft repositioning and endovascular stenting through the femoral and brachial approach. The patient eventually underwent open splenorenal bypass with a Y Gore-Tex graft (W. L. Gore & Associates, Flagstaff, Ariz. After 3 months, computed tomography showed no evidence of endoleak and patent renal arteries. Renal function was well maintained, and the patient did not require dialysis.

  6. Mechanical and electrochemical characteristics with welding materials in robotic MIG welding of dissimilar Al alloys

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Jong; Han, Min Su; Woo, Yong Bin [Mokpo Maritime Univ., Mokpo (Korea, Republic of)

    2013-05-15

    In this study, mechanical and electrochemical characteristics with welding material in MIG welded with ROBOT for dissimilar Al alloys were investigated using various experiment methods. The MIG welding by ROBOT with ER5183 and ER5556 for the 5456-H116 and 6061-T6 Al alloy were carried out. The hardness of welding zone was lower than that of base metal. In electrochemical experiment, ER5183 welding material presented excellent characteristics. The yield strength and maximum tensile strength in welding with welding material of ER5183 presented lower value than those of ER5556. The elongation and time-to-fracture showed the opposite results.

  7. Microstructure and toughness of ferritic weld metal of hyperbaric welded joints

    International Nuclear Information System (INIS)

    Mueller, L.

    1988-01-01

    In the present work ferritic weld metals of hyperbaric MIG/MAG welds with pressures up to 100 bar were examined. As a result of the pressure, interactions with the shielding gas, the filler metal as well as with the welding parameters had to be expected and were consequently included in the analysis. Investigation was focused on the influence of these parameters on the chemical composition of the weld metals, the microstructure and toughness behaviour, including fracture mechanics test. Using quantitative microstructural analysis as well as fractography a correlation between microstructure and toughness has been shown. (orig.) [de

  8. Update on acute endovascular and surgical stroke treatment

    DEFF Research Database (Denmark)

    Kondziella, D; Cortsen, M; Eskesen, V

    2013-01-01

    Emergency stroke care has become a natural part of the emerging discipline of neurocritical care and demands close cooperation between the neurologist and neurointerventionists, neurosurgeons, and anesthesiologists. Endovascular treatment (EVT), including intra-arterial thrombolysis, mechanical...

  9. Structural integrity and fatigue crack propagation life assessment of welded and weld-repaired structures

    Science.gov (United States)

    Alam, Mohammad Shah

    2005-11-01

    Structural integrity is the science and technology of the margin between safety and disaster. Proper evaluation of the structural integrity and fatigue life of any structure (aircraft, ship, railways, bridges, gas and oil transmission pipelines, etc.) is important to ensure the public safety, environmental protection, and economical consideration. Catastrophic failure of any structure can be avoided if structural integrity is assessed and necessary precaution is taken appropriately. Structural integrity includes tasks in many areas, such as structural analysis, failure analysis, nondestructive testing, corrosion, fatigue and creep analysis, metallurgy and materials, fracture mechanics, fatigue life assessment, welding metallurgy, development of repairing technologies, structural monitoring and instrumentation etc. In this research fatigue life assessment of welded and weld-repaired joints is studied both in numerically and experimentally. A new approach for the simulation of fatigue crack growth in two elastic materials has been developed and specifically, the concept has been applied to butt-welded joint in a straight plate and in tubular joints. In the proposed method, the formation of new surface is represented by an interface element based on the interface potential energy. This method overcomes the limitation of crack growth at an artificial rate of one element length per cycle. In this method the crack propagates only when the applied load reaches the critical bonding strength. The predicted results compares well with experimental results. The Gas Metal Arc welding processes has been simulated to predict post-weld distortion, residual stresses and development of restraining forces in a butt-welded joint. The effect of welding defects and bi-axial interaction of a circular porosity and a solidification crack on fatigue crack propagation life of butt-welded joints has also been investigated. After a weld has been repaired, the specimen was tested in a universal

  10. Analysis of the Corrosion Behavior of an A-TIG Welded SS 409 Weld Fusion Zone

    Science.gov (United States)

    Vidyarthy, R. S.; Dwivedi, D. K.

    2017-11-01

    AISI 409 (SS 409) ferritic stainless steel is generally used as the thick gauge section in freight train wagons, in ocean containers, and in sugar refinery equipment. Activating the flux tungsten inert gas (A-TIG) welding process can reduce the welding cost during fabrication of thick sections. However, corrosion behavior of the A-TIG weld fusion zone is a prime concern for this type of steel. In the present work, the effect of the A-TIG welding process parameters on the corrosion behavior of a weld fusion zone made of 8-mm-thick AISI 409 ferritic stainless-steel plate has been analyzed. Potentiodynamic polarization tests were performed to evaluate the corrosion behavior. The maximum corrosion potential ( E corr) was shown by the weld made using a welding current of 215 A, a welding speed of 95 mm/min, and a flux coating density of 0.81 mg/cm2. The minimum E corr was observed in the weld made using a welding current of 190 A, a welding speed of 120 mm/min, and a flux coating density of 1.40 mg/cm2. The current study also presents the inclusive microstructure-corrosion property relationships using the collective techniques of scanning electron microscopy, energy-dispersive x-ray spectroscopy, and x-ray diffraction.

  11. Reinforcement of a plate weakened by multiple holes with several patches for different types of plate-patch attachment

    KAUST Repository

    Zemlyanova, A.

    2014-01-24

    The most general situation of the reinforcement of a plate with multiple holes by several patches is considered. There is no restriction on the number and the location of the patches. Two types of patch attachment are considered: only along the boundary of the patch or both along the boundary of the patch and the boundaries of the holes which this patch covers. The unattached boundaries of the holes may be loaded with given in-plane stresses. The mechanical problem is reduced to a system of singular integral equations which can be further reduced to a system of Fredholm equations. A new numerical procedure for the solution of the system of singular integral equations is proposed in this paper. It is demonstrated on numerical examples that this procedure has advantages in the case of multiple patches and holes and allows achievement of better numerical convergence with less computational effort.

  12. Microstructures and electrochemical behaviors of the friction stir welding dissimilar weld.

    Science.gov (United States)

    Shen, Changbin; Zhang, Jiayan; Ge, Jiping

    2011-06-01

    By using optical microscope, the microstructures of 5083/6082 friction stir welding (FSW) weld and parent materials were analyzed. Meanwhile, at ambient temperature and in 0.2 mol/L NaHS03 and 0.6 mol/L NaCl solutionby gravimetric test, potentiodynamic polarization curve test, electrochemical impedance spectra (EIS) and scanning electron microscope (SEM) observation, the electrochemical behavior of 5083/6082 friction stir welding weld and parent materials were comparatively investigated by gravimetric test, potentiodynamic polarization curve test, electrochemical impedance spectra (EIS) and scanning electron microscope (SEM) observation. The results indicated that at given processing parameters, the anti-corrosion property of the dissimilar weld was superior to those of the 5083 and 6082 parent materials. Copyright © 2011 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.

  13. DEA deformed stretchable patch antenna

    International Nuclear Information System (INIS)

    Jiang, X-J; Jalali Mazlouman, S; Menon, C; Mahanfar, A; Vaughan, R G

    2012-01-01

    A stretchable patch antenna (SPA) whose frequency is tuned by a planar dielectric elastomer actuator (DEA) is presented in this paper. This mechanically reconfigurable antenna system has a configuration resembling a pre-stretched silicone belt. Part of the belt is embedded with a layer of conductive liquid metal to form the patch antenna. Part of the belt is sandwiched between conductive electrodes to form the DEA. Electrical activation of the DEA results in a contraction of the patch antenna, and as a result, in a variation of its resonance frequency. Design and fabrication steps of this system are presented. Measurement results for deformation, resonance frequency variation and efficiency of the patch antenna are also presented. (paper)

  14. Properties of welded joints in laser welding of aeronautic aluminum-lithium alloys

    Science.gov (United States)

    Malikov, A. G.; Orishich, A. M.

    2017-01-01

    The work presents the experimental investigation of the laser welding of the aluminum-lithium alloys (system Al-Mg-Li) and aluminum alloy (system Al-Cu-Li) doped with Sc. The influence of the nano-structuring of the surface layer welded joint by the cold plastic deformation method on the strength properties of the welded joint is determined. It is founded that, regarding the deformation degree over the thickness, the varying value of the welded joint strength is different for these aluminum alloys.

  15. Tailor-welded blanks and their production

    Science.gov (United States)

    Yan, Qi

    2005-01-01

    Tailor welded blanks had been widely used in the automobile industry. A tailor welded blank consists of several flat sheets that were laser welded together before stamping. A combination of different materials, thickness, and coatings could be welded together to form a blank for stamping car body panels. As for the material for automobile industry, this technology was one of the development trend for automobile industry because of its weight reduction, safety improvement and economical use of materials. In this paper, the characters and production of tailor welded blanks in the market were discussed in detail. There had two major methods to produce tailor welded blanks. Laser welding would replace mesh seam welding for the production of tailor welded blanks in the future. The requirements on the edge preparation of unwelded blanks for tailor welded blanks were higher than the other steel processing technology. In order to produce the laser welded blank, there had the other process before the laser welding in the factory. In the world, there had three kinds of patterns for the large volume production of tailor welded blanks. In China, steel factory played the important role in the promotion of the application of tailor welded blanks. The competition for the supply of tailor welded blanks to the automobile industry would become fierce in the near future. As a result, the demand for the quality control on the production of tailor welded blanks would be the first priority concern for the factory.

  16. Patching. Restitching business portfolios in dynamic markets.

    Science.gov (United States)

    Eisenhardt, K M; Brown, S L

    1999-01-01

    In turbulent markets, businesses and opportunities are constantly falling out of alignment. New technologies and emerging markets create fresh opportunities. Converging markets produce more. And of course, some markets fade. In this landscape of continuous flux, it's more important to build corporate-level strategic processes that enable dynamic repositioning than it is to build any particular defensible position. That's why smart corporate strategists use patching, a process of mapping and remapping business units to create a shifting mix of highly focused, tightly aligned businesses that can respond to changing market opportunities. Patching is not just another name for reorganizing; patchers have a distinctive mindset. Traditional managers see structure as stable; patching managers believe structure is inherently temporary. Traditional managers set corporate strategy first, but patching managers keep the organization focused on the right set of business opportunities and let strategy emerge from individual businesses. Although the focus of patching is flexibility, the process itself follows a pattern. Patching changes are usually small in scale and made frequently. Patching should be done quickly; the emphasis is on getting the patch about right and fixing problems later. Patches should have a test drive before they're formalized but then be tightly scripted after they've been announced. And patching won't work without the right infrastructure: modular business units, fine-grained and complete unit-level metrics, and companywide compensation parity. The authors illustrate how patching works and point out some common stumbling blocks.

  17. The Effect of Welding Energy on the Microstructural and Mechanical Properties of Ultrasonic-Welded Copper Joints

    Science.gov (United States)

    Yang, Jingwei; Cao, Biao; Lu, Qinghua

    2017-01-01

    The effects of welding energy on the mechanical and microstructural characteristics of ultrasonic-welded pure copper plates were investigated. Complex dynamic recrystallization and grain growth occurred inside the weld zone during ultrasonic welding. At a low welding energy, a thin band of straight weld interfaces was observed and had an ultra-fine grain structure. With an increase in welding energy, the weld interface progressively changed from flat to sinusoidal, and eventually turned into a convoluted wavy pattern, bearing similarities to shear instabilities, as observed in fluid dynamics. The lap shear load of the joints initially increased and then remained stable as the welding energy increased. The tensile characteristics of the joints significantly depended on the development of plastic deformation at the interface. The influence of the microstructure on the hardness was also discussed. PMID:28772553

  18. Endovascular stenting of a chronic ruptured type B thoracic aortic dissection, a second chance: a case report.

    Science.gov (United States)

    Arshad, Ali; Khan, Sumaira L; Whitaker, Simon C; Macsweeney, Shane T

    2008-02-07

    We aim to highlight the need for awareness of late complications of endovascular thoracic aortic stenting and the need for close follow-up of patients treated by this method. We report the first case in the English literature of an endovascular repair of a previously stented, ruptured chronic Stanford type B thoracic aortic dissection re-presenting with a type III endoleak of the original repair. Endovascular thoracic stenting is now a widely accepted technique for the treatment of thoracic aortic dissection and its complications. Long term follow up is necessary to ensure that late complications are identified and treated appropriately. In this case of type III endoleak, although technically challenging, endovascular repair was feasible and effective.

  19. Influence of the welding temperature and the welding speed on the mechanical properties of friction stir welds in EN AW-2219-T87

    Science.gov (United States)

    Bachmann, A.; Krutzlinger, M.; Zaeh, M. F.

    2018-06-01

    Friction Stir Welding (FSW) is an innovative joining technique, which has proven to produce high quality joints in high strength aluminum alloys. Consequently, it is commonly used to manufacture lightweight aerospace structures with stringent requirements. For these structures, it is necessary to ensure a high ultimate tensile strength (UTS). Various studies have reported that the UTS is significantly influenced by the welding parameters. Samples welded with different parameter sets showed a considerably different UTS, despite being free from detectable welding defects (e.g. tunnel defect, voids, or lack of penetration). Based on the observations in the literature, a hypothesis was posed. The welding temperature along with the welding speed determine the UTS of the weld. This study aims to prove this hypothesis experimentally by using temperature-controlled FSW to join plates of EN AW-2219-T87 in butt joint configuration. The welded samples were examined using visual inspection, metallography, X-ray imaging, and uniaxial tensile tests. Finally, a statistical analysis was conducted. Hereby, the hypothesis was confirmed.

  20. Rabbit models of cerebral vasospasm established with endovascular puncture

    International Nuclear Information System (INIS)

    Tu Jianfei; Liu Yizhi; Ji Jiansong; Zhao Zhongwei

    2008-01-01

    Objective: To investigate the method of endovascular puncture to establish rabbit models of cerebral vasospasm. Methods: New Zealand white rabbits were divided into 5 groups (12 h, 1 d, 2 d, 3 d and 7 d) randomly, and each group was separated into subarachnoid hemorrhage (SAH) subgroup (n=5) and control subgroup (n=2). cerebral vascular spasm (CVS) models were established after SAH with endovascular puncture. CT scans before and after operation were performed. The internal diameters and the wall thicknesses of posterior communicans artery (PcoA) and basilar artery (BA) were measured with HE stain after the animals were executed. Results: CVS model was successfully eastblished in 35 rabbits (SAH subgroup 25, control subgroup 10), resulting a successful rate of 48.61%. Compared with control subgroup, PcoA and BA showed shrinkage of internal diameters of 43.60% and 51.82% 12 h after SAH, respectively, and the shrinkage appeared as biphasic patterns until the 7th study day with another peaks of 29.32% and 45.19%, respectively. Conclusions: Endovascular puncture is an effective method to establish rabbit of CVS. The death rate of animals can be decreased with the asage of new interventional material and perfection for the details of operation. (authors)

  1. Emergent Endovascular Management of Acute Arterial Bleeding ...

    African Journals Online (AJOL)

    multiruka1

    little attention has been paid to the novel endovascular options available .... Fig 1b. Fig 1c. Figure 1a: Mass at gastric fundus enhanced in post contrast CT abdomen. ... 1c: Left gastric artery super selectively coiled to occlusion. Fig 2a. Fig 2b.

  2. FuncPatch: a web server for the fast Bayesian inference of conserved functional patches in protein 3D structures.

    Science.gov (United States)

    Huang, Yi-Fei; Golding, G Brian

    2015-02-15

    A number of statistical phylogenetic methods have been developed to infer conserved functional sites or regions in proteins. Many methods, e.g. Rate4Site, apply the standard phylogenetic models to infer site-specific substitution rates and totally ignore the spatial correlation of substitution rates in protein tertiary structures, which may reduce their power to identify conserved functional patches in protein tertiary structures when the sequences used in the analysis are highly similar. The 3D sliding window method has been proposed to infer conserved functional patches in protein tertiary structures, but the window size, which reflects the strength of the spatial correlation, must be predefined and is not inferred from data. We recently developed GP4Rate to solve these problems under the Bayesian framework. Unfortunately, GP4Rate is computationally slow. Here, we present an intuitive web server, FuncPatch, to perform a fast approximate Bayesian inference of conserved functional patches in protein tertiary structures. Both simulations and four case studies based on empirical data suggest that FuncPatch is a good approximation to GP4Rate. However, FuncPatch is orders of magnitudes faster than GP4Rate. In addition, simulations suggest that FuncPatch is potentially a useful tool complementary to Rate4Site, but the 3D sliding window method is less powerful than FuncPatch and Rate4Site. The functional patches predicted by FuncPatch in the four case studies are supported by experimental evidence, which corroborates the usefulness of FuncPatch. The software FuncPatch is freely available at the web site, http://info.mcmaster.ca/yifei/FuncPatch golding@mcmaster.ca Supplementary data are available at Bioinformatics online. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  3. Influence of habitat quality, population size, patch size, and connectivity on patch-occupancy dynamics of the middle spotted woodpecker.

    Science.gov (United States)

    Robles, Hugo; Ciudad, Carlos

    2012-04-01

    Despite extensive research on the effects of habitat fragmentation, the ecological mechanisms underlying colonization and extinction processes are poorly known, but knowledge of these mechanisms is essential to understanding the distribution and persistence of populations in fragmented habitats. We examined these mechanisms through multiseason occupancy models that elucidated patch-occupancy dynamics of Middle Spotted Woodpeckers (Dendrocopos medius) in northwestern Spain. The number of occupied patches was relatively stable from 2000 to 2010 (15-24% of 101 patches occupied every year) because extinction was balanced by recolonization. Larger and higher quality patches (i.e., higher density of oaks >37 cm dbh [diameter at breast height]) were more likely to be occupied. Habitat quality (i.e., density of large oaks) explained more variation in patch colonization and extinction than did patch size and connectivity, which were both weakly associated with probabilities of turnover. Patches of higher quality were more likely to be colonized than patches of lower quality. Populations in high-quality patches were less likely to become extinct. In addition, extinction in a patch was strongly associated with local population size but not with patch size, which means the latter may not be a good surrogate of population size in assessments of extinction probability. Our results suggest that habitat quality may be a primary driver of patch-occupancy dynamics and may increase the accuracy of models of population survival. We encourage comparisons of competing models that assess occupancy, colonization, and extinction probabilities in a single analytical framework (e.g., dynamic occupancy models) so as to shed light on the association of habitat quality and patch geometry with colonization and extinction processes in different settings and species. ©2012 Society for Conservation Biology.

  4. PATIENTS' KNOWLEDGE OF MEDICAL PATCHES IN HUNGARY.

    Science.gov (United States)

    Somogyi, Orsolya; Zelko, Romana

    2016-11-01

    Transdermal therapy with medical patches is a simple possibility in home medication. As the correct use of patches has a decisive impact from the point of its modulator effect.A questionnaire survey was developed to explore level of patients' knowledge of the correct use of transdermal patches. A survey was administered in thirteen Hungarian community pharmacies from October of 2012 to May of 2015. Most of the participants, men and women over 18 years of age (n = 233), used major analgesic patches (fentanyl); the remainder were given nitroglycerin, NSAID analgesics patches during the survey. For the hypothesis testing it was assumed that men were more likely to use a razor for skin depilation before patch application than women as their denser pelage hinders patch adhesion. The hypothesis testing showed no significant gender difference in razor use (X² = 0.201; p = 0.654). Pharmacists should direct patients to avoid using soap for skin cleansing before patch application because only 22 percent of the participants always avoided its use. Since only 9 tests were flawless from 233 completed questionnaires. Many patients do not understand how to correctly apply a transdermal dosage patch. Pharmacists should teach their correct application based on results.

  5. Plasma Processes of Cutting and Welding

    Science.gov (United States)

    1976-02-01

    TIG process. 2.2.2 Keyhole Welding In plasma arc welding , the term...Cutting 3 3 4 4 4 2.2 Plasma Arc Welding 5 2.2.1 Needle Arc Welding 2.2.2 Keyhole Welding 5 6 3. Applications 8 93.1 Economics 4. Environmental Aspects of...Arc Lengths III. Needle Arc Welding Conditions IV. Keyhole Welding Conditions v. Chemical Analyses of Plates Used - vii - 1. 2. 3. 4. 5. 6. 7. 8.

  6. 10,170 flawless welds

    CERN Multimedia

    Antonella Del Rosso

    2014-01-01

    The welding of tubes containing the principal current-carrying busbars in the LHC magnets was one of the main activities of the SMACC project. After a year of preparation and another of intense activity in the tunnel, the last weld was completed on Wednesday 14 May. Over 10,170 welds have been inspected and not a single fault has been found.    The welder (above) creates the weld using an orbital welding machine (below) specifically designed for CERN. Each of the eight sectors of the LHC contains around 210 interconnects between the superconducting magnets. Consolidating these interconnections was the SMACC project’s primary objective. One of the last jobs before closing the interconnects is the welding of the M lines: each has a 104 mm diameter and a radial clearance of just 45 mm. In total: 10,170 welds carried out in a single year of activities. A true challenge, which was carried out by a team of 30 highly specialised welders, working under the supervision o...

  7. Effects of Flux Precoating and Process Parameter on Welding Performance of Inconel 718 Alloy TIG Welds

    Science.gov (United States)

    Lin, Hsuan-Liang; Wu, Tong-Min; Cheng, Ching-Min

    2014-01-01

    The purpose of this study is to investigate the effect of activating flux on the depth-to-width ratio (DWR) and hot cracking susceptibility of Inconel 718 alloy tungsten inert gas (TIG) welds. The Taguchi method is employed to investigate the welding parameters that affect the DWR of weld bead and to achieve optimal conditions in the TIG welds that are coated with activating flux in TIG (A-TIG) process. There are eight single-component fluxes used in the initial experiment to evaluate the penetration capability of A-TIG welds. The experimental results show that the Inconel 718 alloy welds precoated with 50% SiO2 and 50% MoO3 flux were provided with better welding performance such as DWR and hot cracking susceptibility. The experimental procedure of TIG welding process using mixed-component flux and optimal conditions not only produces a significant increase in DWR of weld bead, but also decreases the hot cracking susceptibility of Inconel 718 alloy welds.

  8. Effect of rotation speed and welding speed on Friction Stir Welding of AA1100 Aluminium alloy

    Science.gov (United States)

    Raja, P.; Bojanampati, S.; Karthikeyan, R.; Ganithi, R.

    2018-04-01

    Aluminum AA1100 is the most widely used grade of Aluminium due to its excellent corrosion resistance, high ductility and reflective finish, the selected material was welded with Friction Stir Welding (FSW) process on a CNC machine, using a combination of different tool rotation speed (1500 rpm, 2500 rpm, 3500 rpm) and welding speed (10 mm/min, 30 mm/min, 50 mm/min) as welding parameters. The effect of FSW using this welding parameter was studied by measuring the ultimate tensile strength of the welded joints. A high-speed steel tool was prepared for welding the Aluminium AA1100 alloy having an 8mm shoulder diameter and pin dimension of 4mm diameter and 2.8 mm length. The welded joints were tested using the universal testing machine. It was found that Ultimate Tensile Strength of FSW specimen was highest with a value of 98.08 MPa when the weld was performed at rotation speed of 1500 RPM and welding speed of 50 mm/min.

  9. New process for weld metal reliability

    International Nuclear Information System (INIS)

    Hebel, A.G.

    1985-01-01

    The industry-wide nature of weld cracking alerts one to the possibility that there is a fundamental law being overlooked. And in overlooking this law, industry is unable to counteract it. That law mandates that restraint during welding causes internal stress; internal stress causes weld metal to crack. Component restraint during welding, according to the welding standard, is the major cause of weld metal failures. When the metal working industry accepts this fact and begins to counter the effects of restraint, the number of weld failures experienced fall dramatically. Bonal Technologies, inc., of Detroit, has developed the first consistently effective non-thermal process to relieve stress caused by restraint during welding. Bonal's patented Mets-Lax sub-resonant stress relief acts as a restraint neutralizer when used during welding. Meta-Lax weld conditioning produces a finer more uniform weld grain structure. A finer, more uniform grain structure is a clear metallurgical indication of improved mechanical weld properties. Other benefits like less internal stress, and less warpage are also achieved

  10. Effects of alloying element on weld characterization of laser-arc hybrid welding of pure copper

    Science.gov (United States)

    Hao, Kangda; Gong, Mengcheng; Xie, Yong; Gao, Ming; Zeng, Xiaoyan

    2018-06-01

    Effects of alloying elements of Si and Sn on weld characterizations of laser-arc hybrid welded pure copper (Cu) with thickness of 2 mm was studied in detail by using different wires. The weld microstructure was analyzed, and the mechanical properties (micro-hardness and tensile property), conductivity and corrosion resistance were tested. The results showed that the alloying elements benefit the growth of column grains within weld fusion zone (FZ), increase the ultimate tensile strength (UTS) of the FZ and weld corrosion resistance, and decrease weld conductivity. The mechanisms were discussed according to the results.

  11. Nondestructive testing: welding industry

    International Nuclear Information System (INIS)

    Raj, Baldev; Subramanian, C.V.

    1992-01-01

    This chapter highlights various conventional and advanced nondestructive testing (NDT) techniques that have been used for weld evaluation. Welding Codes and Standards of International and National organisations that have been followed in India for various weld evaluation purposes are also included. The chapter also emphasises the importance of NDT by way of a few case studies that have been carried out on important critical welded components. (author). 12 refs., 17 figs., 1 appendix

  12. Finite element simulation of the welding process and structural behaviour of welded components

    International Nuclear Information System (INIS)

    Locci, J.M.; Rouvray, A. de; Barbe, B.; Poirier, J.

    1977-01-01

    In the field of inelastic analysis of nuclear metal structures, the computation of residual stresses in welds, and their effects on the strength of welded components is of major importance. This paper presents an experimentally checked finite element simulation with the general nonlinear program PAM NEP-D, of the electron beam welding of two thick hemispherical shells, and the behaviour of the welded sphere under various additional thermomechanical sollicitations. (Auth.)

  13. Corrosion Behavior of Arc Weld and Friction Stir Weld in Al 6061-T6 Alloys

    International Nuclear Information System (INIS)

    Yoon, Byoung Hyun; Kim, Heung Ju; Chang, Woong Seong; Kweon, Young Gak

    2006-01-01

    For the evaluation of corrosion resistance of Al 6061-T6 Alloy, Tafel method and immersion test was performed with Friction Stir Weld(FSW) and Gas Metal Arc Weld(GMAW). The Tafel and immersion test results indicated that GMA weld was severely attacked compared with those of friction stir weld. It may be mainly due to the galvanic corrosion mechanism act on the GMA weld

  14. Metallurgical and fatigue assessments of welds in cast welded hydraulic turbine runners

    International Nuclear Information System (INIS)

    Trudel, A; Sabourin, M

    2014-01-01

    Decades of hydraulic turbine operation around the world have shown one undeniable fact; welded turbine runners can be prone to fatigue cracking, especially in the vicinity of welds. In this regard, three factors are essential to consider in runner fatigue assessments: (1) the runner's design, which can induce stress concentrations in the fillets, (2) the casting process, which inherently creates defects such as shrinkage cavities and (3) the welding process, which induces significant residual stresses as well as a heat affected zone in the cast pieces near the interface with the filler metal. This study focuses on the latter, the welding process, with emphasis on the influence of the heat affected zone on the runner's fatigue behavior. In a recently concluded study by a large research consortium in Montreal, the microstructure and fatigue crack propagation properties of a CA6NM runner weld heat affected zone were thoroughly investigated to find if this zone deteriorates the runner's resistance to fatigue cracking. The main results showed that this zone's intrinsic fatigue crack propagation resistance is only slightly lower than the unaffected base metal because of its somewhat finer martensitic microstructure leading to a less tortuous crack path. However, it was also confirmed that weld-induced residual stresses represent the dominant influencing factor regarding fatigue crack propagation, though post-weld heat treatments are usually very effective in reducing such residual stresses. This paper aims to further confirm, through a case study, that the weld-induced heat affected zone does not compromise the reliability of welded turbine runners when its fatigue crack propagation properties are considered in fatigue damage models

  15. Endovascular Placement of an Extraluminal Femoropopliteal Bypass Graft in Human Cadavers

    International Nuclear Information System (INIS)

    Maynar, Manuel; Llorens, Rafael; Lopez-Sanchez, Carmen; Garcia-Martinez, Virginio; Qian Zhong; Lopera, Jorge; Castaneda, Wilfrido R.

    2005-01-01

    Purpose. A method to create an extraluminal femoropopliteal bypass graft using endovascular techniques was evaluated in situ on cadaver extremities in an attempt to develop a minimally invasive alternative technique for the management of infrainguinal occlusive arterial disease. Methods. The endovascular placement of an extraluminal femoropopliteal bypass graft was undertaken in 5 cadaver legs. Following percutaneous access to the popliteal artery (PA) or common femoral artery (CFA), a Rosch-Uchida needle was used to perforate the vascular wall, followed by the creation of an extraluminal tract using a looped wire and catheter. Once the desired level was reached the needle was again used to perforate the vascular wall of the proximal superficial femoral artery (SFA) or PA depending on the access used. Self-expanding expanded polytetrafluoroethylene (ePTFE) stent-grafts were then deployed to establish the extraluminal femoropopliteal bypass connecting the two arterial puncture sites. Following dilatation of the stent-graft, angiography was performed to assess the endoprostheses and to look for contrast leaks. Results. Technical success was achieved in all 5 legs. Procedure time varied from 15 to 30 min. The angiographic studies performed immediately after completion of the bypass procedure showed patency of the grafts with no evidence of kinking or leakage in any of the cases. Conclusion. This study has proved that the endovascular placement of an extraluminal femoropopliteal bypass graft in human cadaver legs using endovascular techniques under fluoroscopic control is technically feasible

  16. Neonatal Intracranial Aneurysm Rupture Treated by Endovascular Management: A Case Report

    Directory of Open Access Journals (Sweden)

    Yi-Pei Tai

    2010-08-01

    Full Text Available Pediatric intracranial aneurysm rupture is rare, and is traditionally managed by surgical clipping. To the best of our knowledge, endovascular embolization of aneurysms in neonates has not previously been reported in Taiwan. We report a 9-day-old boy with intracranial aneurysms who underwent endovascular embolization, representing the youngest reported case in Taiwan. The 9-day-old boy presented with non-specific symptoms of irritable crying, seizure and respiratory distress. Computed tomography disclosed intraventricular hemorrhage, subarachnoid hemorrhage and focal intracranial hemorrhage around the right cerebellum. Subsequent computed tomographic angiography showed two sequential fusiform aneurysms, measuring 3 mm, located in the right side posterior inferior cerebellar artery (PICA. The patient underwent endovascular embolization because of the high risk of aneurysm re-rupture and the impossibility of surgical clipping due to the fusiform nature of the aneurysms. A postembolization angiogram revealed complete obliteration of the right distal PICA and proximal aneurysm. The distal PICA aneurysm was revascularized from the collateral circulation, but demonstrated a slow and delayed filling pattern. The patient's condition remained stable over the following week, and he was discharged without anticonvulsant therapy. No significant developmental delay was noted at follow-up at when he was 3 months old. This case emphasizes the need for clinical practitioners to consider a diagnosis of intracranial hemorrhage in neonates with seizure and increased intracranial pressure. Neonatal intracranial aneurysms can be treated safely by endovascular treatment.

  17. Numerical evaluation of multipass welding temperature field in API 5L X80 steel welded joints

    Directory of Open Access Journals (Sweden)

    J Nóbrega

    2016-10-01

    Full Text Available Many are the metallurgical changes suffered by materials when subjected to welding thermal cycle, promoting a considerable influence on the welded structures thermo mechanical properties. In project phase, one alternative for evaluating the welding cycle variable, would be the employment of computational methods through simulation. So, this paper presents an evaluation of the temperature field in a multipass welding of API 5L X80 steel used for oil and gas transportation, using the ABAQUS ® software, based on Finite Elements Method (FEM. During the simulation complex phenomena are considerable including: Variation in physical and mechanical properties of materials as a function of temperature, welding speed and the different mechanisms of heat exchange with the environment (convection and radiation were used. These considerations allow a more robust mathematical modeling for the welding process. An analytical heat source proposed by Goldak, to model the heat input in order to characterize the multipass welding through the GTAW (Gas Tungsten Arc Welding process on root and the SMAW (Shielded Metal Arc Welding process for the filling passes were used. So, it was possible to evaluate the effect of each welding pass on the welded joint temperature field, through the temperature peaks and cooling rates values during the welding process.

  18. Galvanic corrosion of beryllium welds

    International Nuclear Information System (INIS)

    Hill, M.A.; Butt, D.P.; Lillard, R.S.

    1997-01-01

    Beryllium is difficult to weld because it is highly susceptible to cracking. The most commonly used filler metal in beryllium welds is Al-12 wt.% Si. Beryllium has been successfully welded using Al-Si filler metal with more than 30 wt.% Al. This filler creates an aluminum-rich fusion zone with a low melting point that tends to backfill cracks. Drawbacks to adding a filler metal include a reduction in service temperature, a lowering of the tensile strength of the weld, and the possibility for galvanic corrosion to occur at the weld. To evaluate the degree of interaction between Be and Al-Si in an actual weld, sections from a mock beryllium weldment were exposed to 0.1 M Cl - solution. Results indicate that the galvanic couple between Be and the Al-Si weld material results in the cathodic protection of the weld and of the anodic dissolution of the bulk Be material. While the cathodic protection of Al is generally inefficient, the high anodic dissolution rate of the bulk Be during pitting corrosion combined with the insulating properties of the Be oxide afford some protection of the Al-Si weld material. Although dissolution of the Be precipitate in the weld material does occur, no corrosion of the Al-Si matrix was observed

  19. Automatic welding of stainless steel tubing

    Science.gov (United States)

    Clautice, W. E.

    1978-01-01

    The use of automatic welding for making girth welds in stainless steel tubing was investigated as well as the reduction in fabrication costs resulting from the elimination of radiographic inspection. Test methodology, materials, and techniques are discussed, and data sheets for individual tests are included. Process variables studied include welding amperes, revolutions per minute, and shielding gas flow. Strip chart recordings, as a definitive method of insuring weld quality, are studied. Test results, determined by both radiographic and visual inspection, are presented and indicate that once optimum welding procedures for specific sizes of tubing are established, and the welding machine operations are certified, then the automatic tube welding process produces good quality welds repeatedly, with a high degree of reliability. Revised specifications for welding tubing using the automatic process and weld visual inspection requirements at the Kennedy Space Center are enumerated.

  20. Endovascular repair of an aorto-iliac aneurysm succeeded by kidney transplantation Tratamento endovascular de aneurisma aorto-ilíaco sucedido por transplante renal

    Directory of Open Access Journals (Sweden)

    Marcelo Bellini Dalio

    2010-09-01

    Full Text Available We present the case of aorto-iliac aneurysm in a patient with chronic renal failure requiring dialysis who were treated with an endovascular stent graft and, later on, submitted to kidney transplantation. A 53-year-old male with renal failure requiring dialysis presented with an asymptomatic abdominal aorto-iliac aneurysm measuring 5.0cm of diameter. He was treated with endovascular repair technique, being used an endoprosthesis Excluder®. After four months, he was successfully submitted to kidney transplantation (dead donor, with anastomosis of the graft renal artery in the external iliac artery distal to the endoprosthesis. The magnetic resonance imaging, carried out 30 days after the procedure, showed a good positioning of the endoprosthesis and adequate perfusion of the renal graft. In the follow-up, the patient presented improvement of nitrogenous waste, good positioning of the endoprosthesis without migration or endoleak. The endovascular repair of aorto-iliac aneurysm in a patient with end-stage renal failure under hemodialysis treatment showed to be feasible, safe and efficient, as it did not prevent the success of the posterior kidney transplantation.Apresentamos o caso de aneurisma aortoilíaco em um paciente com insuficiência renal crônica dialítica tratado com uma endoprótese vascular, sendo, após, submetido a transplante renal. Um homem de 53 anos com insuficiência renal dialítica apresentava um aneurisma abdominal aortoilíaco assintomático com 5,0cm de diâmetro. Foi tratado com técnica endovascular com uma endoprótese Excluderâ. Após quatro meses, foi submetido a transplante renal (doador cadáver com sucesso, com anastomose da artéria renal do enxerto na artéria ilíaca externa distal à endoprótese. A ressonância magnética 30 dias após o procedimento mostrou a endoprótese bem posicionada e o enxerto renal bem perfundido. No seguimento, o paciente evoluiu com melhora das escórias nitrogenadas, bom

  1. Hepatic vascular injury: Clinical profile, endovascular management and outcomes

    Directory of Open Access Journals (Sweden)

    Bishav Mohan

    2013-01-01

    Conclusion: Prompt endovascular management is the modality of choice in comparison to NOM without AE in both pediatric and adult patients with hemodynamically compromised inaccessible intra hepatic vascular trauma.

  2. Carotid artery revascularization : Surgical and endovascular developments

    NARCIS (Netherlands)

    Borst, G.J. de

    2007-01-01

    Carotid artery revascularization. Surgical and endovascular developments. Stroke is among the most disabling chronic diseases and the third major cause of death in the Western world. In the Netherlands around 12 per 1000 inhabitants suffers a stroke, and in 2005 over 10.000 people died as a result

  3. Upgraded HFIR Fuel Element Welding System

    International Nuclear Information System (INIS)

    Sease, John D.

    2010-01-01

    The welding of aluminum-clad fuel plates into aluminum alloy 6061 side plate tubing is a unique design feature of the High Flux Isotope Reactor (HFIR) fuel assemblies as 101 full-penetration circumferential gas metal arc welds (GMAW) are required in the fabrication of each assembly. In a HFIR fuel assembly, 540 aluminum-clad fuel plates are assembled into two nested annular fuel elements 610 mm (24-inches) long. The welding process for the HFIR fuel elements was developed in the early 1960 s and about 450 HFIR fuel assemblies have been successfully welded using the GMAW process qualified in the 1960 s. In recent years because of the degradation of the electronic and mechanical components in the old HFIR welding system, reportable defects in plate attachment or adapter welds have been present in almost all completed fuel assemblies. In October 2008, a contract was awarded to AMET, Inc., of Rexburg, Idaho, to replace the old welding equipment with standard commercially available welding components to the maximum extent possible while maintaining the qualified HFIR welding process. The upgraded HFIR welding system represents a major improvement in the welding system used in welding HFIR fuel elements for the previous 40 years. In this upgrade, the new inner GMAW torch is a significant advancement over the original inner GMAW torch previously used. The innovative breakthrough in the new inner welding torch design is the way the direction of the cast in the 0.762 mm (0.030-inch) diameter aluminum weld wire is changed so that the weld wire emerging from the contact tip is straight in the plane perpendicular to the welding direction without creating any significant drag resistance in the feeding of the weld wire.

  4. Ultrasonic inspection of austenitic welds

    International Nuclear Information System (INIS)

    Baikie, B.L.; Wagg, A.R.; Whittle, M.J.; Yapp, D.

    1976-01-01

    Optical and X-ray metallography combined with ultrasonic testing by compression waves was used for inspection of stainless steel weld metal produced by three different welding techniques. X-ray diffraction showed that each weld possessed a characteristic fibre textured structure which was shown by optical microscopy to be parallel to columnar grain boundaries. Metallographic evidence suggested that the development of fibre texture is due to the mechanism of competitive growth. From observations made as a result of optical metallographic examination the orientation of the fibre axis could be predicted if the weld geometry and welding procedure were known. Ultrasonic velocity and attenuation measurements as a continuous function of grain orientation, made on cylinders machined from weld samples, showed that attenuation was strongly orientation dependent. It was concluded that the sensitivity of ultrasonic inspection to small defects is unlikely to be as high for austenitic welds as for ferritic even when transmission is improved by modifying the welding procedure to improve the ultrasonic transmission. (U.K.)

  5. Challenges to Resistance Welding

    DEFF Research Database (Denmark)

    Song, Quanfeng

    This report originates from the compulsory defense during my Ph.D. study at the Technical University of Denmark. Resistance welding is an old and well-proven technology. Yet the emergence of more and more new materials, new designs, invention off new joining techniques, and more stringent...... requirement in quality have imposed challenges to the resistance welding. More some research and development have to be done to adapt the old technology to the manufacturing industry of the 21st century. In the 1st part of the report, the challenging factors to the resistance welding are reviewed. Numerical...... simulation of resistance welding has been under development for many years. Yet it is no easy to make simulation results reliable and accurate because of the complexity of resistance welding process. In the 2nd part of the report numerical modeling of resistance welding is reviewed, some critical factors...

  6. Weld pool and keyhole dynamic analysis based on visual system and neural network during laser keyhole welding

    OpenAIRE

    Luo, Masiyang

    2014-01-01

    In keyhole fiber laser welding processes, the weld pool behavior and keyhole dynamics are essential to determining welding quality. To observe and control the welding process, the accurate extraction of the weld pool boundary as well as the width is required. In addition, because of the cause-and-effect relationship between the welding defects and stability of the keyhole, which is primarily determined by keyhole geometry during the welding process, the stability of keyhole needs to be consid...

  7. Endovascular Tubular Stent-Graft Placement for Isolated Iliac Artery Aneurysms

    International Nuclear Information System (INIS)

    Okada, Takuya; Yamaguchi, Masato; Kitagawa, Atsushi; Kawasaki, Ryota; Nomura, Yoshikatsu; Okita, Yutaka; Sugimura, Kazuro; Sugimoto, Koji

    2012-01-01

    Purpose: To evaluate the safety, efficacy, and mid-term outcomes of endovascular tubular stent-graft placement for repair of isolated iliac artery aneurysms (IAAs). Materials and Methods: Between January 2002 and March 2010, 20 patients (7 women and 13 men; mean age 74 years) underwent endovascular repair of 22 isolated IAAs. Two patients underwent endovascular repair for bilateral aneurysms. Ten para-anastomotic aneurysms (45%) developed after open abdominal aortic aneurysm (AAA) repair with an aorto-iliac graft, and 12 were true aneurysms (55%). Eleven straight and 11 tapered stent-grafts were placed. Contrast-enhanced computed tomography (CT) was performed to detect complications and evaluate aneurysmal shrinkage at week 1, 3, 6, and 12 months and once every year thereafter. Non–contrast-enhanced CT was performed in seven patients with chronic kidney disease. Results: All procedures were successful, without serious complications, during the mean (range) follow-up period of 746 days (47–2651). Type II endoleak not requiring treatment was noted in one patient. The mean (SD) diameters of the true and para-anastomotic aneurysms significantly (p < 0.05) decreased from 42.0 (9.3) to 36.9 (13.6) mm and from 40.1 (13.0) to 33.6 (15.8) mm, respectively; the mean (SD) shrinkage rates were 15.1% (20.2%) and 18.9% (22.4%), respectively. The primary patency rate was 100%, and no secondary interventions were required. Four patients (21%) developed transient buttock claudication, and one patient (5%) developed colorectal ischaemia, which was treated conservatively. Conclusion: Endovascular tubular stent-graft placement for the repair of isolated IAAs is safe and efficacious. Tapered stent-grafts of various sizes are required for accurate placement.

  8. IMPROVEMENT OF WELDED CONNECTIONS WITH SIDE LAP WELDS BY REDISTRIBUTION OF ALL-WELD METAL ALONG LENGTHS AND CROSS-SECTIONS THEREOF USING MECHANIZED AND ROBOTIC WELDING SYSTEMS

    Directory of Open Access Journals (Sweden)

    Pavlov Evgeniy Igorevich

    2017-05-01

    Full Text Available Experimental study of bearing capacity of samples of two series performed by semiautomatic welding in CO2 on the axis, and by robotic welding machine in mixture (CO2 + Ar, is presented. Welds of constant cross section, welds with extended leg on end sections, and welds in the form of two dowels on end sections were performed. Efficiency of pilot samples of the first series (with extended leg on end sections by way of a smooth transition defined by the ratio of weld metal volume to a crushing load reaches 28 % relative to samples with a leg constant as per length. Samples of the first series with an extended leg on end sections also showed efficiency increased to 17 %. According to the second series samples test results, the exceeding of bearing capacity of the samples performed with an extended leg on end sections by 24 % in comparison with the samples with a leg of constant cross section was determined. Samples of the second series performed in the form of two dowels on end sections demonstrated the exceeding of the relative bearing capacity by 42 % in comparison with the samples with a continuous leg of constant cross-section.

  9. Welding Current Distribution in the Work-piece and Pool in Arc Welding

    Directory of Open Access Journals (Sweden)

    A. M. Rybachuk

    2015-01-01

    Full Text Available In order to select the optimal configuration of controlling magnetic fields and build rational construction of magnetic systems, we need to know the distribution of welding current in the molten metal of the weld pool. So the objective of the work is to establish the calculated methods for determining current density in the weld pool during arc welding. The distribution of welding current in the pool depends on the field of the electrical resistance, which is determined by the deformed temperature field while arc moves with the welding speed. The previous works have shown experimentally and by simulation on the conductive paper that deformation of temperature field defines deformation of electric field. On the basis thereof, under certain boundary conditions the problem has been solved to give a general solution of differential equation, which relates the potential distribution to the temperature in the product during arc welding. This solution is obtained under the following boundary conditions: 1 metal is homogeneous; 2 input and output surfaces of heat flux and electric current coincide; 3 input and output surfaces of heat flux and electric current are insulated and equipotential; 4 other (lateral surfaces are adiabatic boundaries. Therefore, this paper pays basic attention to obtaining the analytical solution of a general differential equation, which relates distribution of potential to the temperature in the product. It considers the temperature field of the heat source, which moves at a welding speed with normal-circular distribution of the heat flow at a certain concentration factor. The distribution of current density is calculated on the assumption that the welding current is introduced through the same surface as the heat flux and the distribution of current density corresponds to the normally circular at a certain concentration factor. As a result, we get an expression that allows us to calculate the current density from the known

  10. Visualization of Spot- welding Resistance

    Directory of Open Access Journals (Sweden)

    Michal Černý

    2016-01-01

    Full Text Available This contribution devotes to monitoring of processes running during joining of steel sheets by incadescent so called point welding using non-destructive trial method – acoustic emission (AE. The joining process is detailed described within experimental measuring from the point of view of metallurgic effects runnig during weld creation (records obtained by means of AE method. It takes into consideration quality of joined steels within welding data of steel producer. Steel welding (determined by chemical composition during mechanical verification and firmness of welds consider results of measurement AE and fracture effect of point joints. The measurement also demonstrates conclusion about connection of metallurgic processes with material wave effects (AE measurement and their impact on firmness of joint at steel with guaranteed welding, difficult welding and at their potential combination.

  11. A case of acute ischemic colitis after endovascular abdominal aortic aneurysm repair

    Directory of Open Access Journals (Sweden)

    Grigorios Voulalas

    2016-01-01

    Full Text Available Colonic ischemia is a recognized complication of either open or endovascular abdominal aortic aneurysm repair. The clinical difficulty in establishing the diagnosis, the severity of this complication and the patient's poor physiological status may lead to a fatal outcome. We presented a case of ischemic colitis in a patient with patent hypogastric arteries that occurred after an endovascular abdominal aortic aneurysm repair as well as a review of the available literature. The patient's preoperative, intraoperative and postoperative data were recorded. A thorough search through the Google data and Medline to review similar cases or any analyses that referred to ischemic colitis after endovascular abdominal aneurysm repair was conducted. A 76-year-old male was admitted to our department for an elective endovascular repair of an 8 cm in diameter abdominal aortic aneurysm. A Zenith bifurcation graft was implanted. The whole procedure was uneventful and the final angiogram showed an accurate deployment of the endograft without endoleaks and patency of both hypogastric arteries. During the 1st postoperative day, the patient developed symptoms of acute abdomen in combination with metabolic acidosis and oliguria. He underwent an exploratory laparotomy, which revealed necrosis of the sigmoid. A Hartmann's procedure was performed; the patient was transferred to the intensive care unit where he deceased after 24 h. Postoperative ischemic colitis has been described after open abdominal aneurysm repair. The description of this complication has been reported since the early phase of endovascular abdominal aneurysm repair development with a current incidence of 1.5%–3.0%. Possible mechanisms that may contribute to ischemic colitis in spite of the presence of patent hypogastric arteries include atheroembolization, shock, vasopressive drugs and inferior mesenteric artery occlusion.

  12. Clinical outcome after endovascular coil embolization in elderly patients with subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Johansson, M.; Cesarini, K.G.; Ronne-Engstroem, E.; Enblad, P.; Norbaeck, O.; Gal, G.; Tovi, M.; Solander, S.; Contant, C.F.

    2004-01-01

    Subarachnoid hemorrhage (SAH) is not an unusual disease in an elderly population. The clinical outcome has improved over time. It has been suggested that elderly SAH patients would benefit from endovascular aneurysm treatment. The aim of this study was to evaluate technical results and clinical outcome in a series of elderly SAH-patients treated with endovascular coil embolization. Sixty-two patients (≥ 65 years) presenting with aneurysmal SAH underwent early endovascular coil embolization at Uppsala University Hospital between September 1996 and December 2000. In all 62 cases included in the study, endovascular coil embolization was considered the first line of treatment. Admission variables, specific information on technical success, degree of occlusion and procedural complications, and outcome figures were recorded. Clinical grade on admission was Hunt and Hess (H and H) I-II in 39%, H and H III in 27% and H and H IV-V in 34% of the patients. The proportion of posterior circulation aneurysms was 24%. Coil embolization was successfully completed in 94%. The degree of occlusion of the treated aneurysm was complete occlusion in 56%, neck remnant in 21%, residual filling in 11%, other remnant in 5% and not treated in 6%. The rate of procedural complications was 11%. Outcome after 6 months was favorable in 41%, severe disability in 36% and poor in 22%. Favorable outcome was achieved in 57% of the H and H I-II patients, 47% of the H and H III patients and 17% of the H and H IV-V patients. Endovascular aneurysm treatment can be performed in elderly patients with SAH with a high level of technical success, acceptable aneurysm occlusion results, an acceptable rate of procedural complications and fair outcome results. (orig.)

  13. Method for welding beryllium

    Science.gov (United States)

    Dixon, R.D.; Smith, F.M.; O`Leary, R.F.

    1997-04-01

    A method is provided for joining beryllium pieces which comprises: depositing aluminum alloy on at least one beryllium surface; contacting that beryllium surface with at least one other beryllium surface; and welding the aluminum alloy coated beryllium surfaces together. The aluminum alloy may be deposited on the beryllium using gas metal arc welding. The aluminum alloy coated beryllium surfaces may be subjected to elevated temperatures and pressures to reduce porosity before welding the pieces together. The aluminum alloy coated beryllium surfaces may be machined into a desired welding joint configuration before welding. The beryllium may be an alloy of beryllium or a beryllium compound. The aluminum alloy may comprise aluminum and silicon. 9 figs.

  14. Method for welding beryllium

    International Nuclear Information System (INIS)

    Dixon, R.D.; Smith, F.M.; O'Leary, R.F.

    1997-01-01

    A method is provided for joining beryllium pieces which comprises: depositing aluminum alloy on at least one beryllium surface; contacting that beryllium surface with at least one other beryllium surface; and welding the aluminum alloy coated beryllium surfaces together. The aluminum alloy may be deposited on the beryllium using gas metal arc welding. The aluminum alloy coated beryllium surfaces may be subjected to elevated temperatures and pressures to reduce porosity before welding the pieces together. The aluminum alloy coated beryllium surfaces may be machined into a desired welding joint configuration before welding. The beryllium may be an alloy of beryllium or a beryllium compound. The aluminum alloy may comprise aluminum and silicon. 9 figs

  15. Endovascular Treatment of Ruptured Abdominal Aortic Aneurysm with Aortocaval Fistula

    International Nuclear Information System (INIS)

    Guzzardi, Giuseppe; Fossaceca, Rita; Divenuto, Ignazio; Musiani, Antonello; Brustia, Piero; Carriero, Alessandro

    2010-01-01

    Aortocaval fistula (ACF) is a rare complication of abdominal aortic aneurysm (AAA). We report the endovascular repair of an AAA rupture into the inferior vena cava. A 78-year-old woman was admitted to our hospital for acute hypotension. She presented with a pulsatile abdominal mass and became rapidly anuric. Abdominal computed tomography (CT) showed an AAA rupture into the inferior vena cava. The features of the AAA made it suitable for endovascular repair. To prevent pulmonary embolism caused by the presence of sac thrombosis near the vena cava lumen, a temporary vena cava filter was deployed before the procedure. A bifurcated stent-graft was placed with the patient under local anaesthesia, and the AAA was successfully treated. A transient type II endoleak was detected on CT 3 days after endograft placement. At routine follow-up 6 and 12 months after the procedure, the patient was in good clinical condition, and the type II endoleak had sealed completely. Endovascular treatment offers an attractive therapeutic alternative to open repair in case of ACF; however, only small numbers of patients have been treated, and long-term follow-up interval is lacking.

  16. Characterization of duplex stainless steel weld metals obtained by hybrid plasma-gas metal arc welding

    Directory of Open Access Journals (Sweden)

    Koray Yurtisik

    2013-09-01

    Full Text Available Despite its high efficiency, autogenous keyhole welding is not well-accepted for duplex stainless steels because it causes excessive ferrite in as-welded duplex microstructure, which leads to a degradation in toughness and corrosion properties of the material. Combining the deep penetration characteristics of plasma arc welding in keyhole mode and metal deposition capability of gas metal arc welding, hybrid plasma - gas metal arc welding process has considered for providing a proper duplex microstructure without compromising the welding efficiency. 11.1 mm-thick standard duplex stainless steel plates were joined in a single-pass using this novel technique. Same plates were also subjected to conventional gas metal arc and plasma arc welding processes, providing benchmarks for the investigation of the weldability of the material. In the first place, the hybrid welding process enabled us to achieve less heat input compared to gas metal arc welding. Consequently, the precipitation of secondary phases, which are known to be detrimental to the toughness and corrosion resistance of duplex stainless steels, was significantly suppressed in both fusion and heat affected zones. Secondly, contrary to other keyhole techniques, proper cooling time and weld metal chemistry were achieved during the process, facilitating sufficient reconstructive transformation of austenite in the ferrite phase.

  17. Spot Welding Characterizations With Time Variable

    International Nuclear Information System (INIS)

    Abdul Hafid; Pinitoyo, A.; History; Paidjo, Andryansyah; Sagino, Sudarmin; Tamzil, M.

    2001-01-01

    For obtain spot welding used effective data, this research is made, so that time operational of machine increasing. Welding parameters are material classification, electrical current, and weld time. All of the factors are determined welding quality. If the plate more thick, the time must be longer when the current constant. Another factor as determined welding quality are surface condition of electrode, surface condition of weld material, and material classifications. In this research, the weld machine type IP32A2 VI (110 V), Rivoira trademark is characterized

  18. Endovascular management of sigmoid sinus dural arteriovenous fistula associated with sinus stenosis in an infant.

    Science.gov (United States)

    Cohen, José E; Gomori, John M; Benifla, Moni; Itshayek, Eyal; Moscovici, Samuel

    2013-01-01

    A 4-month-old female presented with a dural arteriovenous fistula (DAVF), which was successfully managed using endovascular techniques. There are very few case series reporting DAVF in infants younger than 12 months and, to our knowledge, only 60 pediatric patients with DAVF have been reported to date. Although most DAVF have a benign course, they can result in life-threatening hemorrhage. Endovascular therapies are usually indicated in the management of these neurosurgical vascular malformations. Endovascular therapy of DAVF in neonatal patients presents some major issues. Gaining arterial access may be problematic in femoral arteries too small for the introduction of a sizeable guiding catheter. The volumes of contrast and infused fluids must be carefully monitored to prevent fluid overload. Radiation exposure should be restricted as far as possible. This report contributes to the limited body of evidence on neonatal DAVF and its endovascular management. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Functional outcome after primary endovascular therapy or IV thrombolysis alone for stroke. An observational, comparative effectiveness study.

    Science.gov (United States)

    Abilleira, Sònia; Ribera, Aida; Dávalos, Antonio; Ribó, Marc; Chamorro, Angel; Cardona, Pere; Molina, Carlos A; Martínez-Yélamos, Antonio; Urra, Xabier; Dorado, Laura; Roquer, Jaume; Martí-Fàbregas, Joan; Aja, Lucía; Tomasello, Alejandro; Castaño, Carlos; Blasco, Jordi; Cánovas, David; Castellanos, Mar; Krupinski, Jerzy; Guimaraens, Leopoldo; Perendreu, Joan; Ustrell, Xavier; Purroy, Francisco; Gómez-Choco, Manuel; Baiges, Joan Josep; Cocho, Dolores; Saura, Júlia; Gallofré, Miquel

    2014-01-01

    Among the acute ischemic stroke patients with large vessel occlusions and contraindications for the use of IV thrombolysis, mainly on oral anticoagulation or presenting too late, primary endovascular therapy is often performed as an alternative to the standard therapy even though evidence supporting the use of endovascular reperfusion therapies is not yet established. Using different statistical approaches, we compared the functional independence rates at 3 months among patients undergoing primary endovascular therapy and patients treated only with IV thrombolysis. We used data from a prospective, government-mandated and externally audited registry of reperfusion therapies for ischemic stroke (January 2011 to November 2012). Patients were selected if treated with either IV thrombolysis alone (n = 1,582) or primary endovascular thrombectomy (n = 250). A series of exclusions were made to homogenize the clinical characteristics among the two groups. We then carried out multivariate logistic regression and propensity score matching analyses on the final study sample (n = 1,179) to compare functional independence at 3 months, as measured by the modified Rankin scale scores 0-2, between the two groups. The unadjusted likelihood of good outcome was poorer among the endovascular group (OR: 0.69; 95% CI: 0.47-1.0). After adjustment, no differences by treatment modality were seen (OR: 1.51; 95% CI: 0.93-2.43 for primary endovascular therapy). Patients undergoing endovascular thrombectomy within 180-270 min (OR: 2.89; 95% CI: 1.17-7.15) and patients with severe strokes (OR: 1.84; 95% CI: 1.02-3.35) did better than their intravenous thrombolysis counterparts. The propensity score-matched analyses with and without adjustment by additional covariates showed that endovascular thrombectomy was as effective as intravenous thrombolysis alone in achieving functional independence (OR for unadjusted propensity score matched: 1.35; 95% CI: 0.9-2.02, OR for adjusted propensity score

  20. Integrated sensors for robotic laser welding

    NARCIS (Netherlands)

    Iakovou, D.; Aarts, Ronald G.K.M.; Meijer, J.; Beyer, E.; Dausinger, F; Ostendorf, A; Otto, A.

    2005-01-01

    A welding head is under development with integrated sensory systems for robotic laser welding applications. Robotic laser welding requires sensory systems that are capable to accurately guide the welding head over a seam in three-dimensional space and provide information about the welding process as

  1. Characterization of duplex stainless steel weld metals obtained by hybrid plasma-gas metal arc welding

    OpenAIRE

    Yurtisik,Koray; Tirkes,Suha; Dykhno,Igor; Gur,C. Hakan; Gurbuz,Riza

    2013-01-01

    Despite its high efficiency, autogenous keyhole welding is not well-accepted for duplex stainless steels because it causes excessive ferrite in as-welded duplex microstructure, which leads to a degradation in toughness and corrosion properties of the material. Combining the deep penetration characteristics of plasma arc welding in keyhole mode and metal deposition capability of gas metal arc welding, hybrid plasma - gas metal arc welding process has considered for providing a proper duplex mi...

  2. Streamlining of plant patches in streams

    DEFF Research Database (Denmark)

    Jensen, Kaj Sand; Pedersen, Morten Lauge

    2008-01-01

    . Sediment elevation within patches (avg. 4.1 cm) increased significantly with patch length, but did not differ between unstable sand or more stable coarse sediment for the same patch length. Shape of canopy and root area did not change significantly with sediment type. 4. Pressure drag on the canopy...

  3. A Study to Increase Weld Penetration in P91 Steel During TIG Welding by using Activating Fluxes

    Science.gov (United States)

    Singh, Akhilesh Kumar; Kumar, Mayank; Dey, Vidyut; Naresh Rai, Ram

    2017-08-01

    Activated Flux TIG (ATIG) welding is a unique joining process, invented at Paton Institute of electric welding in 1960. ATIG welding process is also known as flux zoned TIG (FZTIG). In this process, a thin layer of activating flux is applied along the line on the surface of the material where the welding is to be carries out. The ATIG process aids to increase the weld penetration in thick materials. Activating fluxes used in the literature show the use of oxides like TiO2, SiO2, Cr2O3, ZnO, CaO, Fe2O3, and MnO2 during welding of steels. In the present study, ATIG was carried out on P-91 steel. Though, Tungsten Inert Gas welding gives excellent quality welds, but the penetration obtained in such welding is still demanding. P91 steel which is ferritic steel is used in high temperature applications. As this steel is, generally, used in thick sections, fabrication of such structures with TIG welding is limited, due to its low depth of penetration. To increase the depth of penetration in P91while welding with ATIG, the role of various oxides were investigated. Apart from the oxides mentioned above, in the present study the role of B2O3, V2O5 and MgO, during ATIG welding of P91 was investigated. It was seen that, compared to TIG welding, there was phenomenal increase in weld penetration during ATIG welding. Amongst all the oxides used in this study, maximum penetration was achieved in case of B2O3. The measurements of weld penetration, bead width and heat affected zone of the weldings were carried out using an image analysis technique.

  4. Residual stress improvement in multi-layer welded plates using water-shower cooling during welding process

    International Nuclear Information System (INIS)

    Yanagida, Nobuyoshi; Koide, Hiroo

    2006-01-01

    To reduce tensile residual stress in a welded region, we developed a new welding method that applies a water-shower behind the welding torch. When this method is applied to welding of austenitic stainless steel plates, cooling conditions mainly determine how much the residual stress can be reduced. To determine the conditions, we first used FEM to evaluate the effects of interpass temperature on the residual stress. And we found effective conditions for reducing tensile residual stress. To verify the validity of the conditions, specimens welded with or without water shower cooling were manufactured. Residual stresses of the specimens were experimentally measured. It was found that tensile residual stresses were generated on the surface of the welds and those were reduced in the case that the water-shower was applied. These measurement results agree well with the FEM analyses. It can therefore be concluded that the water-shower cooling during welding is appropriate for reducing tensile residual stress in austenitic stainless steel welding. (author)

  5. Constructing canine carotid artery stenosis model by endovascular technique

    International Nuclear Information System (INIS)

    Cheng Guangsen; Liu Yizhi

    2005-01-01

    Objective: To establish a carotid artery stenosis model by endovascular technique suitable for neuro-interventional therapy. Methods: Twelve dogs were anesthetized, the unilateral segments of the carotid arteries' tunica media and intima were damaged by a corneous guiding wire of home made. Twenty-four carotid artery stenosis models were thus created. DSA examination was performed on postprocedural weeks 2, 4, 8, 10 to estimate the changes of those stenotic carotid arteries. Results: Twenty-four carotid artery stenosis models were successfully created in twelve dogs. Conclusions: Canine carotid artery stenosis models can be created with the endovascular method having variation of pathologic characters and hemodynamic changes similar to human being. It is useful for further research involving the new technique and new material for interventional treatment. (authors)

  6. Outcomes of endovascular aortic repair in the modern era

    DEFF Research Database (Denmark)

    Budtz-Lilly, Jacob; Wanhainen, Anders; Mani, Kevin

    2018-01-01

    Monitoring outcomes following endovascular aortic repair (EVAR) is critical. Although evidence from randomized controlled trials has solidified the role of EVAR, the analysis of outcomes and "real-world" data has uncovered limitations, improved the selection of appropriate patients, and underscored...... the importance of instructions for use. Subsequent studies demonstrated the learning curve of EVAR and gradual improvement of outcomes over time. Outcomes analyses will continue to play an important role, particularly as technological growth of endovascular therapy has enabled treatment of more complex aneurysm...... pathologies and patients. The important analyses are herein reviewed, following the development of EVAR in the treatment of intact abdominal aortic aneurysms (AAA) to ruptured AAAs, and finally to complex aneurysms, including thoracoabdominal aortic aneurysms and mycotic aneurysms. This includes an overview...

  7. Weld metal microstructures of hardfacing deposits produced by self-shielded flux-cored arc welding

    International Nuclear Information System (INIS)

    Dumovic, M.; Monaghan, B.J.; Li, H.; Norrish, J.; Dunne, D.P.

    2015-01-01

    The molten pool weld produced during self-shielded flux-cored arc welding (SSFCAW) is protected from gas porosity arising from oxygen and nitrogen by reaction ('killing') of these gases by aluminium. However, residual Al can result in mixed micro-structures of δ-ferrite, martensite and bainite in hardfacing weld metals produced by SSFCAW and therefore, microstructural control can be an issue for hardfacing weld repair. The effect of the residual Al content on weld metal micro-structure has been examined using thermodynamic modeling and dilatometric analysis. It is concluded that the typical Al content of about 1 wt% promotes δ-ferrite formation at the expense of austenite and its martensitic/bainitic product phase(s), thereby compromising the wear resistance of the hardfacing deposit. This paper also demonstrates how the development of a Schaeffler-type diagram for predicting the weld metal micro-structure can provide guidance on weld filler metal design to produce the optimum microstructure for industrial hardfacing applications.

  8. Avanços nos materiais e no tratamento endovascular de oclusões arteriais crônicas totais: um relato de caso Advances in materials and endovascular treatment of chronic total arterial occlusions: a case report

    Directory of Open Access Journals (Sweden)

    Daniel Queiroz Neves

    2012-09-01

    Full Text Available As oclusões arteriais crônicas totais com forte componente cálcico são ainda nos dias atuais, um fator muitas vezes limitante para o tratamento endovascular devido à dificuldade em transpor estas lesões com fios-guia e cateteres habitualmente utilizados. Revisamos a literatura e descrevemos um caso de tratamento endovascular de uma oclusão total de artéria ilíaca externa, onde o uso de novos materiais desenvolvidos especificamente para o tratamento deste tipo de lesão foi determinante para o sucesso do caso.Chronic arterial occlusions with great calcium component are usually a factor of limitation to endovascular treatment to the difficulty to transpose these lesions with guidewires and catheters commonly used. We reviewed the literature and described a case of endovascular treatment of a total occlusion of external iliac artery, where the use of new materials developed specifically to the treatment of such injuries was critical to the success of the case.

  9. 49 CFR 192.225 - Welding procedures.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Welding procedures. 192.225 Section 192.225... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Welding of Steel in Pipelines § 192.225 Welding procedures. (a) Welding must be performed by a qualified welder in accordance with welding procedures...

  10. Innovations in vascular and endovascular surgery in Brazil: a data analysis study

    Directory of Open Access Journals (Sweden)

    Heriberto Brito de Oliveira

    2014-12-01

    Full Text Available Background:Innovations in vascular and endovascular surgery have important social and economic repercussions. Most endovascular devices used in Brazil are imported and, therefore, particularly expensive.Objective:To conduct a retrospective analysis of patent and regulatory approval data for newly developed vascular and endovascular devices, based on the number of patents registered at the Brazilian National Industrial Property Institute (INPI and the number of products approved by the National Health Surveillance Agency (ANVISA over recent years.Methods:This retrospective study involved electronic searches of the INPI (www.inpi.gov.br and ANVISA websites (www.anvisa.gov.br, for patents registered and products approved between January 1997 and December 2012.Results:The keywords used for the search ("catheter(s," "stent(s," "graft(s," and "wound dressing(s" returned a total of 701 new patents registered during the period studied. Thirty-four percent (n=237 of these were patents for wound dressings, while the remaining 66% (n=464 were for devices used in endovascular surgery. Only 7.8% (n=268 of the 3433 products approved by ANVISA during the period analyzed were produced in Brazil.Conclusions:The social and economic importance of innovations in health care highlights the need to monitor them, to register them and to support their production, in view of the need to develop local alternatives to imported health care technology.

  11. Fenestrated endovascular aortic aneurysm repair using physician-modified endovascular grafts versus company-manufactured devices.

    Science.gov (United States)

    Dossabhoy, Shernaz S; Simons, Jessica P; Flahive, Julie M; Aiello, Francesco A; Sheth, Parth; Arous, Edward J; Messina, Louis M; Schanzer, Andres

    2017-12-07

    Fenestrated endografts are customized, patient-specific endovascular devices with potential to reduce morbidity and mortality of complex aortic aneurysm repair. With approval from the U.S. Food and Drug Administration, our center began performing fenestrated endovascular aneurysm repair through a physician-sponsored investigational device exemption (IDE #G130210), using both physician-modified endografts (PMEGs) and company-manufactured devices (CMDs). Because these techniques are associated with specific advantages and disadvantages, we sought to investigate differences in outcomes between PMEG and CMD cases. A single-institution retrospective review of all fenestrated endovascular aneurysm repairs was performed. The cohort was analyzed by device type (PMEG or CMD) after matching of cases on the basis of (1) number of target vessels intended for treatment, (2) extent of aneurysm, (3) aneurysm diameter, (4) device configuration, and (5) date of operation. Outcomes of ruptures, common iliac artery aneurysms, and aortic arch aneurysms were excluded. Demographics, operative details, perioperative complications, length of stay, and reinterventions were compared. For patients with >1 year of follow-up time, survival, type I or type III endoleak rate, target artery patency, and reintervention rate were estimated using the Kaplan-Meier method. Between November 30, 2010, and July 30, 2016, 82 patients were identified and matched. The cohort included 41 PMEG and 41 CMD patients who underwent repair of 38 juxtarenal (PMEG, 17; CMD, 21; P = .38), 14 pararenal (PMEG, 6; CMD, 8; P = .56), and 30 thoracoabdominal type I to type IV (PMEG, 18; CMD, 12; P = .17) aneurysms. There were significant differences in presentation requiring urgent aneurysm repair (PMEG, 9; CMD, 0; P = .002), total fluoroscopy time (PMEG, 76 minutes; CMD, 61 minutes; P = .02), volume of contrast material used (PMEG, 88 mL; CMD, 70 mL; P = .02), in-operating room to out-of-operating room time

  12. Outcomes of fenestrated and branched endovascular repair of complex abdominal and thoracoabdominal aortic aneurysms.

    Science.gov (United States)

    Schanzer, Andres; Simons, Jessica P; Flahive, Julie; Durgin, Jonathan; Aiello, Francesco A; Doucet, Danielle; Steppacher, Robert; Messina, Louis M

    2017-09-01

    More than 80% of infrarenal aortic aneurysms are treated by endovascular repair. However, adoption of fenestrated and branched endovascular repair for complex aortic aneurysms has been limited, despite high morbidity and mortality associated with open repair. There are few published reports of consecutive outcomes, inclusive of all fenestrated and branched endovascular repairs, starting from the inception of a complex aortic aneurysm program. Therefore, we examined a single center's consecutive experience of fenestrated and branched endovascular repair of complex aortic aneurysms. This is a single-center, prospective, observational cohort study evaluating 30-day and 1-year outcomes in all consecutive patients who underwent fenestrated and branched endovascular repair of complex aortic aneurysms (definition: requiring one or more fenestrations or branches). Data were collected prospectively through an Institutional Review Board-approved registry and a physician-sponsored investigational device exemption clinical trial (G130210). We performed 100 consecutive complex endovascular aortic aneurysm repairs (November 2010 to March 2016) using 58 (58%) commercially manufactured custom-made devices and 42 (42%) physician-modified devices to treat 4 (4%) common iliac, 42 (42%) juxtarenal, 18 (18%) pararenal, and 36 (36%) thoracoabdominal aneurysms (type I, n = 1; type II, n = 4; type III, n = 12; type IV, n = 18; arch, n = 1). The repairs included 309 fenestrations, branches, and scallops (average of 3.1 branch arteries/case). All patients had 30-day follow-up for 30-day event rates: three (3%) deaths; six (6%) target artery occlusions; five (5%) progressions to dialysis; eight (8%) access complications; one (1%) paraparesis; one (1%) bowel ischemia; and no instances of myocardial infarction, paralysis, or stroke. Of 10 type I or type III endoleaks, 8 resolved (7 with secondary intervention, 1 without intervention). Mean follow-up time was 563 days (interquartile range

  13. Sub-Patch Roughness in Earthquake Rupture Investigations

    KAUST Repository

    Zielke, Olaf; Mai, Paul Martin

    2016-01-01

    Fault geometric complexities exhibit fractal characteristics over a wide range of spatial scales (<µm to >km) and strongly affect the rupture process at corresponding scales. Numerical rupture simulations provide a framework to quantitatively investigate the relationship between a fault's roughness and its seismic characteristics. Fault discretization however introduces an artificial lower limit to roughness. Individual fault patches are planar and sub-patch roughness –roughness at spatial scales below fault-patch size– is not incorporated. Does negligence of sub-patch roughness measurably affect the outcome of earthquake rupture simulations? We approach this question with a numerical parameter space investigation and demonstrate that sub-patch roughness significantly modifies the slip-strain relationship –a fundamental aspect of dislocation theory. Faults with sub-patch roughness induce less strain than their planar-fault equivalents at distances beyond the length of a slipping fault. We further provide regression functions that characterize the stochastic effect sub-patch roughness.

  14. Sub-Patch Roughness in Earthquake Rupture Investigations

    KAUST Repository

    Zielke, Olaf

    2016-02-13

    Fault geometric complexities exhibit fractal characteristics over a wide range of spatial scales (<µm to >km) and strongly affect the rupture process at corresponding scales. Numerical rupture simulations provide a framework to quantitatively investigate the relationship between a fault\\'s roughness and its seismic characteristics. Fault discretization however introduces an artificial lower limit to roughness. Individual fault patches are planar and sub-patch roughness –roughness at spatial scales below fault-patch size– is not incorporated. Does negligence of sub-patch roughness measurably affect the outcome of earthquake rupture simulations? We approach this question with a numerical parameter space investigation and demonstrate that sub-patch roughness significantly modifies the slip-strain relationship –a fundamental aspect of dislocation theory. Faults with sub-patch roughness induce less strain than their planar-fault equivalents at distances beyond the length of a slipping fault. We further provide regression functions that characterize the stochastic effect sub-patch roughness.

  15. GMAW (Gas Metal Arc Welding) process development for girth welding of high strength pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Rajan, Vaidyanath; Daniel, Joe; Quintana, Marie [The Lincoln Electric Company, Cleveland, OH (United States); Chen, Yaoshan [Center for Reliable Energy Systems (CRES), Dublin, OH (United States); Souza, Antonio [Lincoln Electric do Brasil, Guarulhos, SP (Brazil)

    2009-07-01

    This paper highlights some of the results and findings from the first phase of a consolidated program co-funded by US Department of Transportation Pipeline and Hazardous Materials Safety Administration (PHMSA) and Pipeline Research Council Inc (PRCI) to develop pipe weld assessment and qualification methods and optimize X 100 pipe welding technologies. One objective of the program is to establish the range of viable welding options for X 100 line pipe, and define the essential variables to provide welding process control for reliable and consistent mechanical performance of the weldments. In this first phase, a series of narrow gap girth welds were made with pulsed gas metal arc welding (GMAW), instrumented with thermocouples in the heat affected zone (HAZ) and weld metal to obtain the associated thermal profiles, and instrumented to measure true energy input as opposed to conventional heat input. Results reveal that true heat input is 16%-22% higher than conventional heat input. The thermal profile measurements correlate very well with thermal model predictions using true energy input data, which indicates the viability of treating the latter as an essential variable. Ongoing microstructural and mechanical testing work will enable validation of an integrated thermal-microstructural model being developed for these applications. Outputs from this model will be used to correlate essential welding process variables with weld microstructure and hardness. This will ultimately enable development of a list of essential variables and the ranges needed to ensure mechanical properties are achieved in practice, recommendations for controlling and monitoring these essential variables and test methods suitable for classification of welding consumables. (author)

  16. Creep deformation behavior of weld metal and heat affected zone on 316FR steel thick plate welded joint

    International Nuclear Information System (INIS)

    Hongo, Hiromichi; Yamazaki, Masayoshi; Watanabe, Takashi; Kinugawa, Junichi; Tanabe, Tatsuhiko; Monma, Yoshio; Nakazawa, Takanori

    1999-01-01

    Using hot-rolled 316FR stainless plate (50 mm thick) and 16Cr-8Ni-2Mo filler wire, a narrow-gap welded joint was prepared by GTAW (gas tungsten arc welding) process. In addition to conventional round bar specimens of base metals and weld metal, full-thickness joint specimens were prepared for creep test. Creep tests were conducted at 550degC in order to examine creep deformation and rupture behavior in the weld metal of the welded joint. Creep strain distribution on the surface of the joint specimen was measured by moire interferometry. In the welded joint, creep strength of the weld metal zone apart from the surface was larger than that in the vicinity of the surface due to repeating heat cycles during welding. Creep strain and creep rate within the HAZ adjacent to the weld metal zone were smaller than those within the base metal zone. Creep rate of the weld metal zone in the welded joint was smaller than that of the weld metal specimen due to the restraint of the hardened HAZ adjacent to the zone. The full-thickness welded joint specimens showed longer lives than weld metal specimens, though the lives of the latter was shorter than those of the base metal (undermatching). In the full-thickness welded joint specimen, crack started from the last pass layer of the weld metal zone and fracture occurred at the zone. From the results mentioned above, in order to evaluate the creep properties of the welded joint correctly, it is necessary to conduct the creep test using the full-thickness welded joint specimen which includes the weakest zones of the weld metal, the front and back sides of the plate. (author)

  17. Underwater welding of steel

    International Nuclear Information System (INIS)

    Ibarra, S.; Olson, D.L.

    1992-01-01

    A fundamental basis to understand the behavior of wet underwater welding of steel is introduced. Both the pyrometallurgical and physical metallurgy concepts are discussed. Modifications of welding consumables and practice are suggested. This chapter promotes further contributions of meatllurgical research to improve and promote wet underwater welding. (orig.)

  18. Rapid establishment of a regular distribution of adult tropical Drosophila parasitoids in a multi-patch environment by patch defence behaviour.

    Science.gov (United States)

    de Jong, Peter W; Hemerik, Lia; Gort, Gerrit; van Alphen, Jacques J M

    2011-01-01

    Females of the larval parasitoid of Drosophila, Asobara citri, from sub-Saharan Africa, defend patches with hosts by fighting and chasing conspecific females upon encounter. Females of the closely related, palearctic species Asobara tabida do not defend patches and often search simultaneously in the same patch. The effect of patch defence by A. citri females on their distribution in a multi-patch environment was investigated, and their distributions were compared with those of A. tabida. For both species 20 females were released from two release-points in replicate experiments. Females of A. citri quickly reached a regular distribution across 16 patches, with a small variance/mean ratio per patch. Conversely, A. tabida females initially showed a clumped distribution, and after gradual dispersion, a more Poisson-like distribution across patches resulted (variance/mean ratio was closer to 1 and higher than for A. citri). The dispersion of A. tabida was most probably an effect of exploitation: these parasitoids increasingly made shorter visits to already exploited patches. We briefly discuss hypotheses on the adaptive significance of patch defence behaviour or its absence in the light of differences in the natural history of both parasitoid species, notably the spatial distribution of their hosts.

  19. The investigation of typical welding defects for 5456 aluminum alloy friction stir welds

    International Nuclear Information System (INIS)

    Chen Huabin; Yan Keng; Lin Tao; Chen Shanben; Jiang Chengyu; Zhao Yong

    2006-01-01

    The external factors on the friction stir welding defects are so abundant that the experiments of friction stir welding were conducted for 5456 aluminum alloy. With the changes of the tool tilt angle and material condition, defects can be generated. These defects can be conventional ones (lack of penetration or voids), or lazy S, which are unique to friction stir welding. However, the origin of the defects remains an area of uncertainty. In this study, an attempt has been made to investigate the formation of these defects. The typical welding defects of friction stir welding joint for 5456 aluminum alloy were analyzed and discussed, respectively, by using optical microscopy (OM), energy-dispersive X-ray spectroscopy (EDS) and scanning electron microscope (SEM). The microscopic examination of the nugget zone and fracture location of the weld confirms that the tilt angle can change the plastic material flow patterns in the stir zone and accordingly control the weld properties. In addition, the oxide layer from the initial butt surface during FSW is dispersed at the grain boundary. These A1 2 O 3 particles are actually the major cause of failure of the joint

  20. Laser welding engineering

    International Nuclear Information System (INIS)

    Bhieh, N. M.; El Eesawi, M. E.; Hashkel, A. E.

    2007-01-01

    Laser welding was in its early life used mainly for unusual applications where no other welding process would be suitable that was twenty five years ago. Today, laser welding is a fully developed part of the metal working industry, routinely producing welds for common items such as cigarette lighters, which springs, motor/transformer lamination, hermetic seals, battery and pacemaker cans and hybrid circuit packages. Yet very few manufacturing engineering have seriously considers employing lasers in their own operations. Why? There are many reasons, but a main one must be not acquainted with the operation and capabilities of a laser system. Other reasons, such as a relatively high initial cost and a concern about using lasers in the manufacturing environment, also are frequently cited, and the complexity of the component and flexibility of the light delivery system. Laser welding could be used in place of many different standard processes, such as resistance (spot or seam), submerged arc, RF induction, high-frequency resistance, ultrasonic and electronic and electron-beam. while each of these techniques has established an independent function in the manufacturing world, the flexible laser welding approach will operate efficiently and economically in many different applications. Its flexibility will even permit the welding system to be used for other machining function, such as drilling, scribing, sealing and serializing. In this article, we will look at how laser welding works and what benefits it can offer to manufacturing engineers. Some industry observers state that there are already 2,000 laser machine tools being used for cutting, welding and drilling and that the number could reach 30,000 over the next 15 years as manufacturing engineers become more aware of the capabilities of lasers [1). While most laser applications are dedicated to one product or process that involves high-volume, long-run manufacturing, the flexibility of a laser to supply energy to hard

  1. Effect of welding processes on the impression creep resistance of type 316 LN stainless steel weld joints

    International Nuclear Information System (INIS)

    Vasudevan, M.; Vasantharaja, P.; Sisira, P.; Divya, K.; Ganesh Sundara Raman, S.

    2016-01-01

    Type 316 LN stainless steel is the major structural material used in the construction of fast breeder reactors. Activated Tungsten Inert Gas (A-TIG) welding , a variant of the TIG welding process has been found to enhance the depth of penetration significantly during autogenous welding and also found to enhance the creep rupture life in stainless steels. The present study aims at comparing the effect of TIG and A-TIG welding processes on the impression creep resistance of type 316 LN stainless steel base metal, fusion zone and heat affected zone (HAZ) of weld joints. Optical and TEM have been used to correlate the microstructures with the observed creep rates of various zones of the weld joints. Finer microstructure and higher ferrite content was observed in the TIG weld joint fusion zone. Coarser grain structure was observed in the HAZ of the weld joints. Impression creep rate of A-TIG weld joint fusion zone was almost equal to that of the base metal and lower than that of the TIG weld joint fusion zone. A-TIG weld joint HAZ was found to have lower creep rate compared to that of conventional TIG weld joint HAZ due to higher grain size. HAZ of the both the weld joints exhibited lower creep rate than the base metal. (author)

  2. Tensile Properties of Friction Stir Welded Joints of AA 2024-T6 Alloy at Different Welding Speeds

    Science.gov (United States)

    Avula, Dhananjayulu; Devuri, Venkateswarlu; Cheepu, Muralimohan; Dwivedi, Dheerendra Kumar

    2018-03-01

    The influence of welding speed on the friction stir welded joint properties of hardness, tensile properties, defects and microstructure characterization are studied in the present study. The friction stir welding was conducted on AA2014-T6 heat treated alloy with 5 mm thickness plate in butt joint configuration. The welding speed was varied from 8 mm/min to 120 mm/min at the fixed travel speed and load conditions. It is observed that the welding speeds at higher rate with wide range can be possible to weld this alloy at higher rates of tool revolution suggesting that the inherent capability of friction stir welding technique for aluminum 2014 alloys. The strength of the joints gradually increases with enhancing of welding speed. The micro structural observations exhibited the formation of equiaxed grains in the stir zone and slightly in the thermo-mechanically affected zone. In addition, the size of the grains decreases with increase in welding speed owing to the presence of low heat input. Hence the hardness of the joints slightly increased in the stir zones over the other zones of the weld nugget. The joint strength initially increases with the welding speed and starts to decreases after reaching to the maximum value. The relationship between the welding conditions and friction stir welded joint properties has been discussed.

  3. Metals welding by using laser

    International Nuclear Information System (INIS)

    Al-Qaisy, R.A.W.

    1991-01-01

    In the present work, same welding ''conduction limited type'' under atmospheric conditions was performed using pulsed Ng:YAG laser to weld; low carbon steel (LCS), stainless steel (304) (SUS304), stainless steel (303) (SUS303), and brass. Microstructure of welded zone, heat affected zone (HAZ), and the laser energy on penetration depth and effective diameter were studied. Tensile test, micro-hardness, and surface roughness of welded and parent metals were also dealt with. Melting efficiency was worked out and an under vacuum seam welding of low carbon steel has been accomplished. Finally spot welding of aluminium tungsten, and platinium wires were employed using different layer energies. 34 tabs.; 82 figs.; 51 refs.; 1 app

  4. Corrosion of carbon steel welds

    International Nuclear Information System (INIS)

    Daniel, B.

    1988-09-01

    This report assesses the factors which cause preferential attack to occur in carbon steel fusion welds. It was concluded that the main factors were: the inclusion content of the weld metal, the potential of the weld metal being less noble than that of the parent, and the presence of low-temperature transformation products in the heat-affected zone of the weld. These factors should be minimized or eliminated as appropriate so that the corrosion allowances determined for carbon steel waste drums is also adequate for the welds. An experimental/theoretical approach is recommended to evaluate the relative corrosion resistance of welds prepared from BS 4360 grade 43A steel to that of the parent material. (author)

  5. *New* CRITICAL Windows Security patch

    CERN Multimedia

    2003-01-01

    On 10 September 2003, Microsoft issued a new CRITICAL security patch, MS03-039. It must be URGENTLY applied on ALL WINDOWS systems, which are not centrally managed for security patches. This includes Experiment computers, Home computers and Windows Portable and Desktop systems not running NICE. Details of the security hole and patch for MS03-039 (which also includes MS03-026) are at: http://cern.ch/it-div/news/hotfix-MS03-039.asp http://www.microsoft.com/technet/security/bulletin/MS03-039.asp

  6. *New*: CRITICAL Windows Security patch

    CERN Multimedia

    2003-01-01

    On 10 September 2003, Microsoft issued a new CRITICAL security patch, MS03-039. It must be URGENTLY applied on ALL WINDOWS systems, which are not centrally managed for security patches. This includes Experiment computers, Home computers and Windows Portable and Desktop systems not running NICE. Details of the security hole and patch for MS03-039 (which also includes MS03-026) are at: http://cern.ch/it-div/news/hotfix-MS03-039.asp http://www.microsoft.com/technet/security/bulletin/MS03-039.asp

  7. Construct Validity and Reliability of Structured Assessment of endoVascular Expertise in a Simulated Setting

    DEFF Research Database (Denmark)

    Bech, B; Lönn, L; Falkenberg, M

    2011-01-01

    Objectives To study the construct validity and reliability of a novel endovascular global rating scale, Structured Assessment of endoVascular Expertise (SAVE). Design A Clinical, experimental study. Materials Twenty physicians with endovascular experiences ranging from complete novices to highly....... Validity was analysed by correlating experience with performance results. Reliability was analysed according to generalisability theory. Results The mean score on the 29 items of the SAVE scale correlated well with clinical experience (R = 0.84, P ... with clinical experience (R = -0.53, P validity and reliability of assessment with the SAVE scale was high when applied to performances in a simulation setting with advanced realism. No ceiling effect...

  8. MFDC - technological improvement in resistance welding controls

    Energy Technology Data Exchange (ETDEWEB)

    Somani, A.K.; Naga Bhaskar, V.; Chandramouli, J.; Rameshwara Rao, A. [Nuclear Fuel Complex, Dept. of Atomic Energy, Hyderabad (India)

    2008-07-01

    Among the various Resistance Welding operations carried out in the production line of a fuel bundle end plug welding is the most critical operation. Welding controllers play a very vital role in obtaining consistent weld quality by regulating and controlling the weld current. Conventional mains synchronized welding controllers are at best capable of controlling the weld current at a maximum speed of the mains frequency. In view of the very short welding durations involved in the various stages of a fuel bundle fabrication, a need was felt for superior welding controllers. Medium Frequency Welding Controllers offer a solution to these limitations in addition to offering other advantages. Medium Frequency power sources offer precise welding current control as they regulate and correct the welding current faster, typically twenty times faster when operated at 1000Hz. An MFDC was employed on one of the welding machines and its performance was studied. This paper discusses about the various advantages of MFDCs with other controllers employed at NFC to end plug welding operation. (author)

  9. Microstructural examination of Zr-2.5%Nb alloy welds made by pulsed Nd:YAG laser and TIG welding technique

    International Nuclear Information System (INIS)

    Bhatt, R.B.; Varma, P.V.S.; Panakkal, J.P.; Srivastava, D.; Dey, G.K.

    2009-01-01

    The paper describes the weld microstructure of Zr-2.5%Nb alloy material. Bead on plate welds were made using pulsed Nd:YAG laser and TIG welding technique at different parameters. These welds were characterized at macro and microstructural level. Weld pools of Pulsed Laser and TIG welds were not resolved by optical microscopy. SEM too did not reveal much. Orientation imaging microscopy could reveal the presence of fine martensite. It was observed that microstructure is very sensitive to welding parameters. Microhardness studies suggested formation of martensite in the weld pool. It was also observed that laser welds had very sharp weld pool boundary as compared to TIG welds. Variation in microhardness of the weldment is seen and is influenced by overlapping of weld spots causing thermal treatment of previously deposited spots. (author)

  10. Recent Corrosion Research Trends in Weld Joints

    International Nuclear Information System (INIS)

    Kim, Hwan Tae; Kil, Sang Cheol; Hwang, Woon Suk

    2007-01-01

    The increasing interest in the corrosion properties of weld joints in the corrosive environment is placing stringent demands on the manufacturing techniques and performance requirements, and the manufacture employs the high quality and efficiency welding process to produce welds. Welding plays an important role in the fabrication of chemical plants, nuclear power plant, ship construction, and this has led to an increasing attention to the corrosion resistant weld joints. This paper covers recent technical trends of welding technologies for corrosion resistance properties including the COMPENDEX DB analysis of welding materials, welding process, and welding fabrications

  11. Machine for welding solar cell connections

    Energy Technology Data Exchange (ETDEWEB)

    Lorans, D.Y.

    1977-08-09

    A machine for welding a connection wire over a solar cell electrode is described which comprises a base, a welding mount for the solar cell which is supported on the base, means for holding the solar cell on the welding mount, welding electrodes, means to lower the welding electrodes over the solar cell and the connection wire superimposed thereon, means for applying electric current pulses to said welding electrodes. It is characterized by the fact that it further comprises means for imparting to said mount an alternating transverse movement in relation to said base before and during the welding operation.

  12. Development of automatic laser welding system

    International Nuclear Information System (INIS)

    Ohwaki, Katsura

    2002-01-01

    Laser are a new production tool for high speed and low distortion welding and applications to automatic welding lines are increasing. IHI has long experience of laser processing for the preservation of nuclear power plants, welding of airplane engines and so on. Moreover, YAG laser oscillators and various kinds of hardware have been developed for laser welding and automation. Combining these welding technologies and laser hardware technologies produce the automatic laser welding system. In this paper, the component technologies are described, including combined optics intended to improve welding stability, laser oscillators, monitoring system, seam tracking system and so on. (author)

  13. Probing weld quality monitoring in friction stir welding through characterization of signals by fractal theory

    Energy Technology Data Exchange (ETDEWEB)

    Das, Bipul; Bag, Swarup; Pal, Sukhomay [Indian Institute of Technology Guwahati, Assam (India)

    2017-05-15

    Providing solutions towards the improvisation of welding technologies is the recent trend in the Friction stir welding (FSW) process. We present a monitoring approach for ultimate tensile strength of the friction stir welded joints based on information extracted from process signals through implementing fractal theory. Higuchi and Katz algorithms were executed on current and tool rotational speed signals acquired during friction stir welding to estimate fractal dimensions. Estimated fractal dimensions when correlated with the ultimate tensile strength of the joints deliver an increasing trend with the increase in joint strength. It is observed that dynamicity of the system strengthens the weld joint, i.e., the greater the fractal dimension, the better will be the quality of the weld. Characterization of signals by fractal theory indicates that the single-valued indicator can be an alternative for effective monitoring of the friction stir welding process.

  14. Probing weld quality monitoring in friction stir welding through characterization of signals by fractal theory

    International Nuclear Information System (INIS)

    Das, Bipul; Bag, Swarup; Pal, Sukhomay

    2017-01-01

    Providing solutions towards the improvisation of welding technologies is the recent trend in the Friction stir welding (FSW) process. We present a monitoring approach for ultimate tensile strength of the friction stir welded joints based on information extracted from process signals through implementing fractal theory. Higuchi and Katz algorithms were executed on current and tool rotational speed signals acquired during friction stir welding to estimate fractal dimensions. Estimated fractal dimensions when correlated with the ultimate tensile strength of the joints deliver an increasing trend with the increase in joint strength. It is observed that dynamicity of the system strengthens the weld joint, i.e., the greater the fractal dimension, the better will be the quality of the weld. Characterization of signals by fractal theory indicates that the single-valued indicator can be an alternative for effective monitoring of the friction stir welding process.

  15. Miniaturization of Multiple-Layer Folded Patch Antennas

    DEFF Research Database (Denmark)

    Zhang, Jiaying; Breinbjerg, Olav

    2009-01-01

    A new folded patch antenna with multiple layers was developed in this paper, by folding the patch in a proper way, and a highly miniaturized antenna can be realized. The multiple layer patch with 4-layer and 6-layer are designed and evaluated at 2.4 GHz, 915 MHz, and 415 MHz respectively. Then a 4...... layer patch is fabricated and measured to validate the design method. The theoretical analysis, design and simulations, fabrications, as well as the measurements are presented in this paper. All the results show that the folded patch antenna is a good candidate in making a highly miniaturized compact...

  16. Advantages of MAG-STT Welding Process for Root Pass Welding in the Oil and Gas Industry

    Directory of Open Access Journals (Sweden)

    Pandzic Adi

    2016-02-01

    Full Text Available This paper describesthe basics of modern MAG-STT welding process and its advantages for root pass welding of construction steels in oil and gas industry. MAG-STT welding process was compared with competitive arc welding processes (SMAW and TIG, which are also used for root pass welding on pipes and plates. After experimental tests, the obtained results are analyzed and presented in this paper

  17. Endovascular interventions for TASC II D femoropopliteal lesions.

    Science.gov (United States)

    Baril, Donald T; Chaer, Rabih A; Rhee, Robert Y; Makaroun, Michel S; Marone, Luke K

    2010-06-01

    Advances in endovascular techniques have provided new options in the treatment of complex infrainguinal occlusive lesions. The purpose of this study was to evaluate outcomes of endovascular interventions on TransAtlantic InterSociety (TASC) II D femoropopliteal occlusive disease. All patients undergoing endovascular interventions for femoropopliteal occlusive disease between July 2004 and July 2009 were reviewed. Patient demographics, pre- and postprocedure ankle-brachial indices (ABI) and anatomic factors were analyzed. Outcomes evaluated included primary patency, assisted-patency, secondary patency, predictors of restenosis, and wound healing. Five hundred eighty-five limbs were treated during the period reviewed. The study group included 79 TASC D limbs in 74 patients (mean age 76.5 +/- 11.9 years, male sex: 53%). Fifty-six limbs (71%) underwent treatment for critical limb ischemia, including 42 (53%) with tissue loss. Eleven patients (15%) had previous failed bypasses. Preoperative ABIs were unobtainable for 23 patients, while the remaining 56 had a mean baseline ABI of 0.54 +/- 0.28. There was one periprocedural mortality. Five patients (6.3%) had periprocedural complications. Mean increase in ABI postprocedure was 0.49 +/- 0.35. Follow-up was available for 74 limbs at a mean of 10.7 months (range, 1-35). There were 18 mortalities (24.3%) during the follow-up period. No patient required a major amputation during this follow-up period. Twenty-one limbs (26.6%) experienced restenosis and nine limbs (11.4%) experienced occlusion. Twenty-nine limbs underwent reintervention during the follow-up time, including nine which underwent multiple reinterventions. Primary, assisted-primary, and secondary patency rates at 12 and 24 months were 52.2%, 88.4%, 92.6% and 27.5%, 74.2%, and 88.9%, respectively. Predictors of restenosis/occlusion included hypercholesterolemia, the presence of a popliteal artery stent, and patients who were current or former smokers. Endovascular

  18. The fluoro-less and contrast-less peripheral endovascular intervention: Halfway there

    Energy Technology Data Exchange (ETDEWEB)

    Ephrem, Georges, E-mail: g.ephrem@gmail.com; Garikipati, Sireesha; Hanson, Ivan D.

    2016-09-15

    Introduction: Percutaneous endovascular revascularization requires the use of fluoroscopic guidance and radiopaque contrast. We present a successful intervention without the use of iodinated contrast. Case: A 92-year-old man with dry gangrene involving the second and fourth left toes had acute on chronic kidney injury. Arterial duplex showed severe stenosis in bilateral superficial femoral arteries (SFAs). Fluoroscopic and ultrasound guidance and intravascular imaging were used to avoid iodinated contrast. After right to left femoral crossover, the entire left SFA was imaged with ultrasound. The lesion was delineated with radiopaque measuring tapes then wired. Near-infrared spectroscopy and intravascular ultrasound (NIRS-IVUS) imaging were performed. Points of interest were correlated with corresponding radiopaque markings on the ruler. Stenting and post-dilation resulted in complete stent expansion and no evidence of dissection by IVUS. The total procedure time was 113 min and the total radiation dose 813 mGy. The day after the procedure, there was a palpable dorsalis pedis pulse. He was discharged to inpatient rehabilitation on dual antiplatelet therapy. Discussion: Contrast and radiation continue to limit the feasibility of endovascular angiography and intervention. Carbon dioxide (CO2) digital subtraction angiography is an alternative for these patients but has several disadvantages. Previously proposed projects demonstrated the real potential of performing endovascular peripheral intervention without fluoroscopy or contrast. Conclusion: This case is a clear demonstration of a successful use of a combination of fluoroscopy, ultrasonography and intravascular imaging to achieve a successful endovascular intervention to treat critical limb ischemia, without the use of iodinated contrast.

  19. Endovascular treatment of the subclavian artery aneurysm in high-risk patient - a single-center experience

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2016-01-01

    Full Text Available We present our first experience with endovascular treatment of 6 subclavian artery aneurysms (SAA occurring in five male and one female patient. All patients, in our studies, according to ASA classification were high risk for open repair of SAA. The etiology of the all aneurysms was atherosclerosis degeneration of the artery. Two aneurysms were of intrathoracic location, then the other were extrathoracic. Symptoms related to subclavian artery aneurysms were present in two patients, compression and chest pain in one, and hemorrhage shock in second, while the remaining patients were asymptomatic. We preferred the Viabhan endoprosthesis for endovascular repair in 5 cases. In one patient with ruptured of subclavian artery aneurysm who was high-risk for open repair we made combined endovascular procedure. First at all, we covered the origin of left subclavian artery with thoracic stent graft and after that we put two coils in proximal part of subclavian artery. There was no operative mortality, and the early patency rate was 100%. The follow-up period was from 3 months to 3 years. During this period, one patient died of heart failure and one patient required endovascular reoperation due to endoleak type I. Endovascular treatment is recommended for all patients with subclavian artery aneurysm whenever this is possible due to anatomical reasons especially in high-risk patient with intrathoracic localization of aneurysm, to prevent potential complications.

  20. Discussion on Integration of Welding Coordinator in Welding Quality System of KEPIC(Korea Electric Power Industry code)

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Hyun-Jae; Sohn, Myoung-Sung; Cho, Kyoung-Youn; Kim, Jong-Hae [Korea Electric Association, Seoul (Korea, Republic of)

    2015-05-15

    The welding quality system of KEPIC-MQW 'Welding Qualification' referencing ASME BPVC Sec.IX, Part QW requires welding procedures and performance qualification of welder or welding operator excluding welding coordinator. It means that there is potential possibility of any problem in process of welding on nuclear power plants or shop in absence of an welding coordinator who can resolve welding troubles. Therefore, the integration of welding coordinators in the welding quality system of KEPIC can improve welding quality and enhance safety of construction and management of power plants. The introduction of welding coordinator requirement would put economic problems on manufactures for new employment and subsequent management works (eg. training) and field problems making authorized nuclear inspectors to be confused on inspection work scopes. Those predictable problems are expected to be minimized or eliminated through public hearings and/or seminars with regulatory body, the owner, and manufacturers and, most significantly, cooperation with related KEPIC committees. The revision draft was reviewed and discussed with personnel in nuclear industry by holding three workshop and public hearings from 2011 to 2012 and by having a presentation in 2014 KEPIC-Week. Industrial consensus on need for integration of welding coordinators in welding quality system of KEPIC was performed by reasons that it would improve welding quality, guarantee welding reliability, advance expertise, and help export to abroad. However, economic problems on manufacturers for new employment and subsequent management works, for example training, are predicted. Therefore, introduction in stages for minimizing industrial impact regarding manufacturer's scale and permission of utilizing external welding coordinator for small scale manufacturers are required. A new draft version of KEPIC-MQW (if possible, appendices of MQW) including requirements and directives for solving these economic

  1. Report Summarizing the Effort Required to Initiate Welding of Irradiated Materials within the Welding Cubicle

    Energy Technology Data Exchange (ETDEWEB)

    Frederick, Greg [Electric Power Research Institute (EPRI), Palo Alto, CA (United States); Sutton, Benjamin J. [Electric Power Research Institute (EPRI), Palo Alto, CA (United States); Tatman, Jonathan K. [Electric Power Research Institute (EPRI), Palo Alto, CA (United States); Vance, Mark Christopher [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Smith, Allen W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Clark, Scarlett R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Feng, Zhili [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Miller, Roger G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Chen, Jian [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Tang, Wei [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hu, Xunxiang [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gibson, Brian T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-06-01

    The advanced welding facility within a hot cell at the Radiochemical Engineering Development Center of Oak Ridge National Laboratory (ORNL), which has been jointly funded by the U.S. Department of Energy (DOE), Office of Nuclear Energy, Light Water Reactor Sustainability Program and the Electric Power Research Institute, Long Term Operations Program and the Welding and Repair Technology Center, is in the final phase of development. Research and development activities in this facility will involve direct testing of advanced welding technologies on irradiated materials in order to address the primary technical challenge of helium induced cracking that can arise when conventional fusion welding techniques are utilized on neutron irradiated stainless steels and nickel-base alloys. This report details the effort that has been required since the beginning of fiscal year 2017 to initiate welding research and development activities on irradiated materials within the hot cell cubicle, which houses welding sub-systems that include laser beam welding (LBW) and friction stir welding (FSW) and provides material containment within the hot cell.

  2. Development of remote laser welding technology

    International Nuclear Information System (INIS)

    Kim, Soo-Sung; Kim, Woong-Ki; Lee, Jung-Won; Yang, Myung-Seung; Park, Hyun-Soo

    1999-01-01

    Various welding processes are now available for end cap closure of nuclear fuel element such as TIG(Tungsten Inert Gas) welding, magnetic resistance welding and laser welding. Even though the resistance and TIG welding process are widely used for manufacturing of the commercial fuel elements, it can not be recommended for the remote seal welding of fuel element at PIE facility due to its complexity of the electrode alignment, difficulty in the replacement of parts in the remote manner and its large heat input for thin sheath. Therefore, Nd:YAG laser system using the optical fiber transmission was selected for Zircaloy-4 end cap welding. Remote laser welding apparatus is developed using a pulsed Nd:YAG laser of 500 watt average power with optical fiber transmission. The laser weldability is satisfactory in respect of the microstructures and mechanical properties comparing with the TIG and resistance welding. The optimum operation processes of laser welding and the optical fiber transmission system for hot cell operation in remote manner have been developed. (author)

  3. Reinforcement of a plate weakened by multiple holes with several patches for different types of plate-patch attachment

    KAUST Repository

    Zemlyanova, A.

    2014-01-01

    the boundary of the patch or both along the boundary of the patch and the boundaries of the holes which this patch covers. The unattached boundaries of the holes may be loaded with given in-plane stresses. The mechanical problem is reduced to a system

  4. Analysis and Comparison of Friction Stir Welding and Laser Assisted Friction Stir Welding of Aluminum Alloy.

    Science.gov (United States)

    Campanelli, Sabina Luisa; Casalino, Giuseppe; Casavola, Caterina; Moramarco, Vincenzo

    2013-12-18

    Friction Stir Welding (FSW) is a solid-state joining process; i.e. , no melting occurs. The welding process is promoted by the rotation and translation of an axis-symmetric non-consumable tool along the weld centerline. Thus, the FSW process is performed at much lower temperatures than conventional fusion welding, nevertheless it has some disadvantages. Laser Assisted Friction Stir Welding (LAFSW) is a combination in which the FSW is the dominant welding process and the laser pre-heats the weld. In this work FSW and LAFSW tests were conducted on 6 mm thick 5754H111 aluminum alloy plates in butt joint configuration. LAFSW is studied firstly to demonstrate the weldability of aluminum alloy using that technique. Secondly, process parameters, such as laser power and temperature gradient are investigated in order to evaluate changes in microstructure, micro-hardness, residual stress, and tensile properties. Once the possibility to achieve sound weld using LAFSW is demonstrated, it will be possible to explore the benefits for tool wear, higher welding speeds, and lower clamping force.

  5. Databases in welding engineering - definition and starting phase of the integrated welding engineering information system

    International Nuclear Information System (INIS)

    Barthelmess, H.; Queren, W.; Stracke, M.

    1989-01-01

    The structure and function of the Information AAssociation for Welding Engineering, newly established by the Deutscher Verband fuer Schweisstechnik, are presented. Examined are: special literature for welding techniques - value and prospects; databases accessible to the public for information on welding techniques; concept for the Information Association for Welding Engineering; the four phases to establish databasis for facts and expert systems of the Information Association for Welding Engineering; the pilot project 'MVT-Data base' (hot crack data base for data of modified varestraint-transvarestraint tests). (orig./MM) [de

  6. Fracture toughness of stainless steel welds

    International Nuclear Information System (INIS)

    Mills, W.J.

    1985-11-01

    The effects of temperature, composition and weld-process variations on the fracture toughness behavior for Types 308 and 16-8-2 stainless steel (SS) welds were examined using the multiple-specimen J/sub R/-curve procedure. Fracture characteristics were found to be dependent on temperature and weld process but not on filler material. Gas-tungsten-arc (GTA) welds exhibited the highest fracture toughness, a shielded metal-arc (SMA) weld exhibited an intermediate toughness and submerged-arc (SA) welds yielded the lowest toughness. Minimum-expected fracture properties were defined from lower-bound J/sub c/ and tearing modulus values generated here and in previous studies. Fractographic examination revealed that microvoid coalescence was the operative fracture mechanism for all welds. Second phase particles of manganese silicide were found to be detrimental to the ductile fracture behavior because they separated from the matrix during the initial stages of plastic straining. In SA welds, the high density of inclusions resulting from silicon pickup from the flux promoted premature dimple rupture. The weld produced by the SMA process contained substantially less manganese silicide, while GTA welds contained no silicide inclusions. Delta ferrite particles present in all welds were substantially more resistant to local failure than the silicide phase. In welds containing little or no manganese silicide, delta ferrite particles initiated microvoid coalescence but only after extensive plastic straining

  7. STUDY AND ANALYSIS OF THE EFFECT OF WELDING PROCESS ON DISTORTION WITH 304L STAINLESS STEEL WELD JOINTS

    OpenAIRE

    Dhananjay Kumar*, Dharamvir mangal

    2017-01-01

    The effect of welding process on the distortion with 304L stainless steel 12thk weld joints made by TIG (tungsten inert gas) and SMAW (Shielded metal arc welding) welding process involving different type joint configuration have been studied. The joint configurations employed were double V-groove edge preparation for double side SMAW welding and square – butt preparation for double side TIG welding. All weld joints passed by radiographic. Distortion measurements were carried out using height ...

  8. Emergency Endovascular Treatment of Abdominal Aortic Aneurysms: Feasibility and Results

    International Nuclear Information System (INIS)

    Lagana, Domenico; Carrafiello, Gianpaolo; Mangini, Monica; Fontana, Federico; Caronno, Roberto; Castelli, Patrizio; Cuffari, Salvatore; Fugazzola, Carlo

    2006-01-01

    Purpose. To assess the feasibility and effectiveness of emergency endovascular treatment of abdominal aortic aneurysms (AAAs). Methods. During 36 months we treated, on an emergency basis, 30 AAAs with endovascular exclusion. In 21 hemodynamically stable patients preoperative CT angiography (CTA) was performed to confirm the diagnosis and to plan the treatment; 9 patients with hemorrhagic shock were evaluated with angiography performed in the operating room. Twenty-two Excluder (Gore) and 8 Zenith (Cook) stent-grafts (25 bifurcated and 5 aorto-uni-iliac) were used. The follow-up was performed by CTA at 1, 3, 6, and 12 months. Results. Technical success was achieved in 100% of cases with a 10% mortality rate. The total complication rate was 23% (5 increases in serum creatinine level and 2 wound infections). During the follow-up, performed in 27 patients (1-36 months, mean 15.2 months), 4 secondary endoleaks (15%) (3 type II, 2 spontaneously thrombosed and 1 under observation, and 1 type III treated by iliac extender insertion) and 1 iliac leg occlusion (treated with femoro-femoral bypass) occurred. We observed a shrinkage of the aneurysmal sac in 8 of 27 cases and stability in 19 of 27 cases; we did not observe any endotension. Conclusions. Endovascular repair is a good option for emergency treatment of AAAs. The team's experience allows correct planning of the procedure in emergency situations also, with technical results comparable with elective repair. In our experience the bifurcated stent-graft is the device of choice in patients with suitable anatomy because the procedure is less time-consuming than aorto-uni-iliac stent-grafting with surgical crossover, allowing faster aneurysm exclusion. However, further studies are required to demonstrate the long-term efficacy of endovascular repair compared with surgical treatment

  9. Solid state impact welding of BMG and copper by vaporizing foil actuator welding

    Energy Technology Data Exchange (ETDEWEB)

    Vivek, Anupam, E-mail: vivek.4@osu.edu [Department of Materials Science and Engineering, The Ohio State University, 2041 College Road, Columbus, OH 43210 (United States); Presley, Michael [Department of Materials Science and Engineering, The Ohio State University, 2041 College Road, Columbus, OH 43210 (United States); Flores, Katharine M. [Department of Materials Science and Engineering, The Ohio State University, 2041 College Road, Columbus, OH 43210 (United States); Department of Mechanical Engineering and Materials Science, Institute of Materials Science and Engineering, Washington University, One Brookings Drive, St. Louis, MO 63130 (United States); Hutchinson, Nicholas H.; Daehn, Glenn S. [Department of Materials Science and Engineering, The Ohio State University, 2041 College Road, Columbus, OH 43210 (United States)

    2015-05-14

    The objective of this study was to create impact welds between a Zr-based Bulk Metallic Glass (BMG) and copper at a laboratory scale and subsequently investigate the relationship between interfacial structure and mechanical properties. Vaporizing Foil Actuator (VFA) has recently been demonstrated as a versatile tool for metalworking applications: impact welding of dissimilar materials being one of them. Its implementation for welding is termed as VFA Welding or VFAW. With 8 kJ input energy into an aluminum foil actuator, a 0.5 mm thick Cu110 alloy sheet was launched toward a BMG target resulting in an impact at a velocity of nearly 600 m/s. For this experiment, the welded interface was straight with a few BMG fragments embedded in the copper sheet in some regions. Hardness tests across the interface showed increase in strength on the copper side. Instrumented peel test resulted in failure in the parent copper sheet. A slower impact velocity during a separate experiment resulted in a weld, which had wavy regions along the interface and in peel failure again happened in the parent copper sheet. Some through-thickness cracks were observed in the BMG plate and there was some spall damage in the copper flyers. TEM electron diffraction on a sample, cut out from the wavy weld interface region using a focused ion beam, showed that devitrification of the BMG was completely avoided in this welding process.

  10. Fatigue life estimation considering welding residual stress and hot-spot stress of welded components

    International Nuclear Information System (INIS)

    Han, S. H.; Lee, T. K.; Shin, B. C.

    2002-01-01

    The fatigue life of welded joints is sensitive to welding residual stress and complexity of their geometric shapes. To predict the fatigue life more reasonably, the effects of welding residual stress and its relaxation have to be considered quantitatively which are equivalent to mean stress by external loads. The hot-spot stress concept should be also adopted which can be reduce the dependence of fatigue strengths for various welding details. Considering the factors mentioned above, a fatigue life prediction model using the modified Goodman's diagram was proposed. In this model, an equivalent stress was introduced which are composed of the mean stress based on the hot-spot stress concept and the relaxed welding residual stress. From the verification of the proposed model to real welding details, it is confirmed that this model can be applied to predict reasonably their fatigue lives

  11. Method for enhanced control of welding processes

    Science.gov (United States)

    Sheaffer, Donald A.; Renzi, Ronald F.; Tung, David M.; Schroder, Kevin

    2000-01-01

    Method and system for producing high quality welds in welding processes, in general, and gas tungsten arc (GTA) welding, in particular by controlling weld penetration. Light emitted from a weld pool is collected from the backside of a workpiece by optical means during welding and transmitted to a digital video camera for further processing, after the emitted light is first passed through a short wavelength pass filter to remove infrared radiation. By filtering out the infrared component of the light emitted from the backside weld pool image, the present invention provides for the accurate determination of the weld pool boundary. Data from the digital camera is fed to an imaging board which focuses on a 100.times.100 pixel portion of the image. The board performs a thresholding operation and provides this information to a digital signal processor to compute the backside weld pool dimensions and area. This information is used by a control system, in a dynamic feedback mode, to automatically adjust appropriate parameters of a welding system, such as the welding current, to control weld penetration and thus, create a uniform weld bead and high quality weld.

  12. Welding wire pressure sensor assembly

    Science.gov (United States)

    Morris, Timothy B. (Inventor); Milly, Peter F., Sr. (Inventor); White, J. Kevin (Inventor)

    1994-01-01

    The present invention relates to a device which is used to monitor the position of a filler wire relative to a base material being welded as the filler wire is added to a welding pool. The device is applicable to automated welding systems wherein nonconsumable electrode arc welding processes are utilized in conjunction with a filler wire which is added to a weld pool created by the electrode arc. The invention senses pressure deviations from a predetermined pressure between the filler wire and the base material, and provides electrical signals responsive to the deviations for actuating control mechanisms in an automatic welding apparatus so as to minimize the pressure deviation and to prevent disengagement of the contact between the filler wire and the base material.

  13. Development of an auto-welding system for CRD nozzle repair welds using a 3D laser vision sensor

    International Nuclear Information System (INIS)

    Park, K.; Kim, Y.; Byeon, J.; Sung, K.; Yeom, C.; Rhee, S.

    2007-01-01

    A control rod device (CRD) nozzle attaches to the hemispherical surface of a reactor head with J-groove welding. Primary water stress corrosion cracking (PWSCC) causes degradation in these welds, which requires that these defect areas be repaired. To perform this repair welding automatically on a complicated weld groove shape, an auto-welding system was developed incorporating a laser vision sensor that measures the 3-dimensional (3D) shape of the groove and a weld-path creation program that calculates the weld-path parameters. Welding trials with a J-groove workpiece were performed to establish a basis for developing this auto-welding system. Because the reactor head is placed on a lay down support, the outer-most region of the CRD nozzle has restricted access. Due to this tight space, several parameters of the design, such as size, weight and movement of the auto-welding system, had to be carefully considered. The cross section of the J-groove weld is basically an oval shape where the included angle of the J-groove ranges from 0 to 57 degrees. To measure the complex shape, we used double lasers coupled to a single charge coupled device (CCD) camera. We then developed a program to generate the weld-path parameters using the measured 3D shape as a basis. The program has the ability to determine the first and final welding positions and to calculate all weld-path parameters. An optimized image-processing algorithm was applied to resolve noise interference and diffused reflection of the joint surfaces. The auto-welding system is composed of a 4-axis manipulator, gas tungsten arc welding (GTAW) power supply, an optimized designed and manufactured GTAW torch and a 3D laser vision sensor. Through welding trials with 0 and 38-degree included-angle workpieces with both J-groove and U-groove weld, the performance of this auto-welding system was qualified for field application

  14. Endovascular Treatment of an Aneurysmal Aberrant Systemic Artery Supplying a Pulmonary Sequestrum

    DEFF Research Database (Denmark)

    Kristensen, Katrine Lawaetz; Duus, Louise Aarup; Elle, Bo

    2015-01-01

    An aberrant systemic artery originating from the abdominal aorta supplying a pulmonary sequestration is a rare congenital malformation. This causes a left-to-left shunt. Symptoms include recurrent pneumonias, hemoptysis, and, in the long term, heart failure. Aneurysm of the aberrant vessel...... is rarely seen. Traditionally, treatment of pulmonary sequestrations includes ligation of the feeding vessel and lobectomy. A new promising treatment is an endovascular approach. Only a few cases describe endovascular treatment of pulmonary sequestration. This is the first published case of a giant...

  15. A comparative study of the microstructure and mechanical properties of HTLA steel welds obtained by the tungsten arc welding and resistance spot welding

    International Nuclear Information System (INIS)

    Ghazanfari, H.; Naderi, M.; Iranmanesh, M.; Seydi, M.; Poshteban, A.

    2012-01-01

    Highlights: ► Hardness mapping is a novel method to identify different phases. ► Surface hardness mapping, tabulates the hardness of a large area of weld. ► Hardness maps can be used to depict the strength map through the specimen. ► Hardness mapping is an easy way to identify the phase fractions within the specimen. - Abstract: Hardness tests are routinely employed as simple and efficient methods to investigate the microstructure and mechanical properties of steels. Each microstructural phase in steel has its own hardness level. Therefore, using surface hardness mapping data over a large area of weld zone would be a reasonable method to identify the present phases in steel. The microstructure distribution and mechanical properties variation through welded structures is inhomogeneous and not suitable for certain applications. So, studying the microstructure of weld zone has a significant importance. 4130 steel is classified in HTLA steels and it is widely used in marine industry due to its superior hardenability, good corrosion resistance and high strength. Gas tungsten arc and resistance spot welding are the most usable processes in joining of 4130 sheets. In this work a series of welds have been fabricated in 4130 steel tube by gas tungsten arc and resistance spot welding. The tube was subjected to quench-tempered heat treatment. Slices from the welds before and after heat treatment were polished and etched and the macrostructure and microstructure were observed. Hardness maps were then determined over the large area of weld zone, including the heat affected zone and base plate. Results show good relations between the various microstructures, strength and hardness values. It is also proved that this method is precise and applicable to estimate phase fraction of each phase in various regions of weld. In the current study some equations were proposed to calculate the ultimate tensile stress and yield stress from the weld. The calculated data were compared

  16. Materials participation in welded joints manufacturing

    Science.gov (United States)

    Ghenghea, L. D.

    2016-08-01

    Management of materials dilution to form a joint with higher features asked by complex metallic structures is a problem that took attention and efforts of welding processes researchers and this communication will give a little contribution presenting some scientific and experimental results of dilution processes studied by Welding Research Group from Iasi, Romania, TCM Department. Liquid state welding processes have a strong dependence related to dilution of base and filler materials, the most important are for automatic joining using welding. The paper presents a review of some scientific works already published and their contributions, results of dilution coefficient evaluation using weighing, graphics and software applied for shielded metal arc welding process. Paper results could be used for welders’ qualification, welding procedure specification and other welding processes researchers’ activities. The results of Welding Research Group from Iasi, Romania, TCM Department, show dilution coefficient values between 20-30 % of base material and 70-80 % of filler material for studied welding process.

  17. Ultrasonic inspection of austenitic welds

    Energy Technology Data Exchange (ETDEWEB)

    Tomlinson, J R; Wagg, A R; Whittle, M J [N.D.T. Applications Centre, CEGB, Manchester (United Kingdom)

    1980-11-01

    The metallurgical structure of austenitic welds is described and contrasted with that found in ferritic welds. It is shown that this structure imparts a marked elastic anisotropy in the ultrasonic propagation parameters. Measurements of variations in the apparent attenuation of sound and deviations in the beam direction are described. The measurements are interpreted in terms of the measured velocity anisotropy. Two applications of the fundamental work are described. In the first it is shown how, by using short pulse compression wave probes, and with major modification of the welding procedure, a stainless steel fillet weld in an AGR boiler can be inspected. In the second application, alternative designs of a transition butt weld have been compared for ease of ultrasonic inspection. The effects of two different welding processes on such an inspection are described. Finally, the paper examines the prospects for future development of inspection and defect-sizing techniques for austenitic welds. (author)

  18. Intensive Care Management of Thoracic Aortic Surgical Patients, Including Thoracic and Infradiaphragmatic Endovascular Repair (EVAR/TEVAR).

    Science.gov (United States)

    Cole, Sheela Pai

    2015-12-01

    The patient with thoracic aortic disease can present for open or endovascular repair. Thoracic endovascular aortic repair (TEVAR) has emerged as a minimally invasive option for a multitude of aortic pathology, including dissections, aneurysms, traumatic injuries, and ulcers. Postoperative management of these patients depends on the extent of procedure, whether it was open or endovascular, and, finally, on the preoperative comorbidities present. While procedural success has catapulted TEVAR to popularity, midterm results have been mixed. Additionally, periprocedural complications such as paraplegia and renal failure remain a significant morbidity in these patients. © The Author(s) 2015.

  19. Weld Growth Mechanisms and Failure Behavior of Three-Sheet Resistance Spot Welds Made of 5052 Aluminum Alloy

    Science.gov (United States)

    Li, Yang; Yan, Fuyu; Luo, Zhen; Chao, Y. J.; Ao, Sansan; Cui, Xuetuan

    2015-06-01

    This paper investigates the weld nugget formation in three-sheet aluminum alloy resistance spot welding. The nugget formation process in three equal thickness sheets and three unequal thickness sheets of 5052 aluminum alloy were studied. The results showed that the nugget was initially formed at the workpiece/workpiece interfaces (i.e., both upper interface and lower interface). The two small nuggets then grew along the radial direction and axial direction (welding direction) as the welding time increased. Eventually, the two nuggets fused into one large nugget. During the welding process, the Peltier effect between the Cu-Al caused the shift of the nugget in the welding direction. In addition, the mechanical strength and fracture mode of the weld nuggets at the upper and lower interfaces were also studied using tensile shear specimen configuration. Three failure modes were identified, namely interfacial, mixed, and pullout. The critical welding time and critical nugget diameter corresponding to the transitions of these modes were investigated. Finally, an empirical failure load formula for three-sheet weld similar to two-sheet spot weld was developed.

  20. Endovascular Interventions for the Morbidly Adherent Placenta

    Directory of Open Access Journals (Sweden)

    Claire Kaufman

    2018-05-01

    Full Text Available Morbidly adherent placentas are a spectrum of abnormalities ranging from placental invasion of the myometrium to invasion past the myometrium and muscular layers into adjacent structures. This entity is becoming more prevalent recently with increased number of cesarean deliveries. Given the high risk of morbidity and mortality, this was traditionally treated with pre-term planned cesarean hysterectomy. However, recently, uterine preservation techniques have been implemented for those women wishing to preserve future fertility or their uterus. Early identification is crucial as studies have shown better outcomes for women treated at tertiary care facilities by a dedicated multidisciplinary team. Interventional radiologists are frequently included in the care of these patients as there are several different endovascular techniques which can be implemented to decrease morbidity in these patients both in conjunction with cesarean hysterectomy and in the setting of uterine preservation. This article will review the spectrum of morbidly adherent placentas, imaging, as well as the surgical and endovascular interventions implemented in the care of these complex patients.

  1. Welding Over Paint Primer

    National Research Council Canada - National Science Library

    Johnson, Kevin S; Liu, Stephen; Olson, David L

    1998-01-01

    .... According to the hydrogen-oxygen and }hydrogen-fluorine equilibrium considerations, an increase in the partial pressure of oxygen or fluorine could decrease the partial pressure of hydrogen within the welding arc. Consequently, a welding consumable that contains chemical ingredients of high oxygen and fluorine potential would be capable of minimizing hydrogen pick-up in the weld pool.

  2. Identification of the Quality Spot Welding used Non Destructive Test-Ultrasonic Testing: (Effect of Welding Time)

    Science.gov (United States)

    Sifa, A.; Endramawan, T.; Badruzzaman

    2017-03-01

    Resistance Spot Welding (RSW) is frequently used as one way of welding is used in the manufacturing process, especially in the automotive industry [4][5][6][7]. Several parameters influence the process of welding points. To determine the quality of a welding job needs to be tested, either by damaging or testing without damage, in this study conducted experimental testing the quality of welding or identify quality of the nugget by using Non-Destructive Test (NDT) -Ultrasonic Testing (UT), in which the identification of the quality of the welding is done with parameter thickness of worksheet after welding using NDT-UT with use same material worksheet and have more thickness of worksheet, the thickness of the worksheet single plate 1mm, with the capability of propagation Ultrasonic Testing (UT) standard limited> 3 mm [1], welding process parameters such as the time difference between 1-10s and the welding current of 8 KV, visually Heat Affected Zone ( HAZ ) have different results due to the length of time of welding. UT uses a probe that is used with a frequency of 4 MHz, diameter 10 mm, range 100 and the couplant used is oil. Identification techniques using drop 6dB, with sound velocity 2267 m / s of Fe, with the result that the effect of the Welding time affect the size of the HAZ, identification with the lowest time 1s show results capable identified joined through NDT - UT.

  3. Gas Metal Arc Welding. Welding Module 5. Instructor's Guide.

    Science.gov (United States)

    Missouri Univ., Columbia. Instructional Materials Lab.

    This guide is intended to assist vocational educators in teaching an eight-unit module in gas metal arc welding. The module is part of a welding curriculum that has been designed to be totally integrated with Missouri's Vocational Instruction Management System. The following topics are covered in the module: safety and testing, gas metal arc…

  4. The importance of expert feedback during endovascular simulator training.

    LENUS (Irish Health Repository)

    Boyle, Emily

    2011-07-01

    Complex endovascular skills are difficult to obtain in the clinical environment. Virtual reality (VR) simulator training is a valuable addition to current training curricula, but is there a benefit in the absence of expert trainers?

  5. Endovascular Treatment for Aneurysmal Subarachnoid Hemorrhage with Neurogenic Pulmonary Edema in the Acute Stage.

    Science.gov (United States)

    Meguro, Toshinari; Tanabe, Tomoyuki; Muraoka, Kenichiro; Terada, Kinya; Hirotsune, Nobuyuki; Nishino, Shigeki

    2016-01-01

    Severe neurogenic pulmonary edema (NPE) can occur in a variety of brain insults, including subarachnoid hemorrhage (SAH), and severe case of NPE can cause devastating consequences. But the literature on the treatment strategy about aneurysmal SAH with NPE is very scant. We present that SAH patients with severe NPE, who were treated first by embolization of aneurysm followed by insertion of lumbar spinal drainage, had comparatively good outcome. We present 12 consecutive cases of aneurysmal SAH with NPE in the acute stage, which were treated by endovascular treatment between April 2002 and December 2012. We classified the patients according to the Hunt and Hess grading system as follows: grade-3 (1 patient), grade-4 (4 patients), and grade-5 (7 patients). All patients needed respiratory management, with the assistance of a ventilator, and underwent endovascular treatment for the ruptured aneurysms within 72 hours from onset. For all the patients, immediately after the endovascular treatment, we performed lumbar spinal drainage. The pulmonary edema disappeared rapidly after respiratory management and endovascular treatment. The outcomes were as follows: good recovery (GR; 3 patients), moderate disability (MD; 4 patients), severe disability (SD; 3 patients), and death (D; 2 patients). Five patients (42%) developed pneumonia, and we postponed extubation until recovery from pneumonia. The cause for severe disability and death was symptomatic vasospasm and primary brain damage. No patients had rebleeding from ruptured aneurysms. Endovascular treatment for ruptured aneurysm and placement of lumbar spinal drainage is an excellent treatment option for severe SAH with NPE.

  6. Recognition and automatic tracking of weld line in fringe welding by autonomous mobile robot with visual sensor

    International Nuclear Information System (INIS)

    Suga, Yasuo; Saito, Keishin; Ishii, Hideaki.

    1994-01-01

    An autonomous mobile robot with visual sensor and four driving axes for welding of pipe and fringe was constructed. The robot can move along a pipe, and detect the weld line to be welded by visual sensor. Moreover, in order to perform welding automatically, the tip of welding torch can track the weld line of the joint by rotating the robot head. In the case of welding of pipe and fringe, the robot can detect the contact angle between the two base metals to be welded, and the torch angle changes according to the contact angle. As the result of tracking test by the robot system, it was made clear that the recognition of geometry of the joint by the laser lighting method and automatic tracking of weld line were possible. The average tracking error was ±0.3 mm approximately and the torch angle could be always kept at the optimum angle. (author)

  7. Spot Welding of Honeycomb Structures

    Science.gov (United States)

    Cohal, V.

    2017-08-01

    Honeycomb structures are used to prepare meals water jet cutting machines for textile. These honeycomb structures are made of stainless steel sheet thickness of 0.1-0.2 mm. Corrugated sheet metal strips are between two gears with special tooth profile. Hexagonal cells for obtaining these strips are welded points between them. Spot welding device is three electrodes in the upper part, which carries three welding points across the width of the strip of corrugated sheet metal. Spot welding device filled with press and advance mechanisms. The paper presents the values of the regime for spot welding.

  8. Comparative estimation of the properties of heat resisting nickel alloy welded joints made by electron-beam and arc welding

    International Nuclear Information System (INIS)

    Morochko, V.P.; Sorokin, L.I.; Yakushin, B.F.; Moryakov, V.F.

    1977-01-01

    As compared to argon arc welding of refractory nickel alloys at 15 m/hour rate, electron beam welding decreases energy consumption per unit length (from 4300 to 2070 cal/cm), the weld area (from 108 to 24 mm 2 ), and the length of the thermal effect zone (from 0.9-1.8 to 0.4-0.8 mm). Electron beam welding also provides for better resistance to hot cracking in the weld metal and in the near-weld zone, as compared to automatic argon arc welding and manual welding with addition of the basic metal. However, this advantage is observed only at welding rates less than 45 m/hour. Electron beam welded joints of refractory nickel alloys with intermetallide reinforcement have higher strength, plasticity and impact strength, and lower scattering of these properties than arc welded joints

  9. Cell-Detection Technique for Automated Patch Clamping

    Science.gov (United States)

    McDowell, Mark; Gray, Elizabeth

    2008-01-01

    A unique and customizable machinevision and image-data-processing technique has been developed for use in automated identification of cells that are optimal for patch clamping. [Patch clamping (in which patch electrodes are pressed against cell membranes) is an electrophysiological technique widely applied for the study of ion channels, and of membrane proteins that regulate the flow of ions across the membranes. Patch clamping is used in many biological research fields such as neurobiology, pharmacology, and molecular biology.] While there exist several hardware techniques for automated patch clamping of cells, very few of those techniques incorporate machine vision for locating cells that are ideal subjects for patch clamping. In contrast, the present technique is embodied in a machine-vision algorithm that, in practical application, enables the user to identify good and bad cells for patch clamping in an image captured by a charge-coupled-device (CCD) camera attached to a microscope, within a processing time of one second. Hence, the present technique can save time, thereby increasing efficiency and reducing cost. The present technique involves the utilization of cell-feature metrics to accurately make decisions on the degree to which individual cells are "good" or "bad" candidates for patch clamping. These metrics include position coordinates (x,y) in the image plane, major-axis length, minor-axis length, area, elongation, roundness, smoothness, angle of orientation, and degree of inclusion in the field of view. The present technique does not require any special hardware beyond commercially available, off-the-shelf patch-clamping hardware: A standard patchclamping microscope system with an attached CCD camera, a personal computer with an imagedata- processing board, and some experience in utilizing imagedata- processing software are all that are needed. A cell image is first captured by the microscope CCD camera and image-data-processing board, then the image

  10. Optimal parameters determination of the orbital weld technique using microstructural and chemical properties of welded joint

    International Nuclear Information System (INIS)

    Miranda, A.; Echevarria, J.F.; Rondon, S.; Leiva, P.; Sendoya, F.A.; Amalfi, J.; Lopez, M.; Dominguez, H.

    1999-01-01

    The paper deals with the study of the main parameters of thermal cycle in Orbital Automatic Weld, as a particular process of the GTAW Weld technique. Also is concerned with the investigation of microstructural and mechanical properties of welded joints made with Orbital Technique in SA 210 Steel, a particular alloy widely use during the construction of Economizers of Power Plants. A number of PC software were used in this sense in order to anticipate the main mechanical and structural characteristics of Weld metal and the Heat Affected Zone (HAZ). The papers also might be of great value during selection of optimal Weld parameters to produce sound and high quality Welds during the construction / assembling of structural components in high requirements industrial sectors and also to make a reliable prediction of weld properties

  11. Ultrasonic Welding of Thermoplastic Composite Coupons for Mechanical Characterization of Welded Joints through Single Lap Shear Testing.

    Science.gov (United States)

    Villegas, Irene F; Palardy, Genevieve

    2016-02-11

    This paper presents a novel straightforward method for ultrasonic welding of thermoplastic-composite coupons in optimum processing conditions. The ultrasonic welding process described in this paper is based on three main pillars. Firstly, flat energy directors are used for preferential heat generation at the joining interface during the welding process. A flat energy director is a neat thermoplastic resin film that is placed between the parts to be joined prior to the welding process and heats up preferentially owing to its lower compressive stiffness relative to the composite substrates. Consequently, flat energy directors provide a simple solution that does not require molding of resin protrusions on the surfaces of the composite substrates, as opposed to ultrasonic welding of unreinforced plastics. Secondly, the process data provided by the ultrasonic welder is used to rapidly define the optimum welding parameters for any thermoplastic composite material combination. Thirdly, displacement control is used in the welding process to ensure consistent quality of the welded joints. According to this method, thermoplastic-composite flat coupons are individually welded in a single lap configuration. Mechanical testing of the welded coupons allows determining the apparent lap shear strength of the joints, which is one of the properties most commonly used to quantify the strength of thermoplastic composite welded joints.

  12. Automatic monitoring of vibration welding equipment

    Science.gov (United States)

    Spicer, John Patrick; Chakraborty, Debejyo; Wincek, Michael Anthony; Wang, Hui; Abell, Jeffrey A; Bracey, Jennifer; Cai, Wayne W

    2014-10-14

    A vibration welding system includes vibration welding equipment having a welding horn and anvil, a host device, a check station, and a robot. The robot moves the horn and anvil via an arm to the check station. Sensors, e.g., temperature sensors, are positioned with respect to the welding equipment. Additional sensors are positioned with respect to the check station, including a pressure-sensitive array. The host device, which monitors a condition of the welding equipment, measures signals via the sensors positioned with respect to the welding equipment when the horn is actively forming a weld. The robot moves the horn and anvil to the check station, activates the check station sensors at the check station, and determines a condition of the welding equipment by processing the received signals. Acoustic, force, temperature, displacement, amplitude, and/or attitude/gyroscopic sensors may be used.

  13. Welding wires for high-tensile steels

    International Nuclear Information System (INIS)

    Laz'ko, V.E.; Starova, L.L.; Koval'chuk, V.G.; Maksimovich, T.L.; Labzina, I.E.; Yadrov, V.M.

    1993-01-01

    Strength of welded joints in arc welding of high-tensile steels of mean and high thickness by welding wires is equal to approximately 1300 MPa in thermohardened state and approximately 600 MPa without heat treatment. Sv-15Kh2NMTsRA-VI (EhK44-VI) -Sv-30Kh2NMTsRA-VI (EkK47-VI) welding wires are suggested for welding of medium-carbon alloyed steels. These wires provide monotonous growth of ultimate strength of weld metal in 1250-1900 MPa range with increase of C content in heat-treated state

  14. Mechanical properties of dissimilar friction welded steel bars in relation to post weld heat treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Yu Sik; Kim, Seon Jin [Pukyong National University, Busan (Korea, Republic of)

    2006-04-15

    Dissimilar friction welding were produced using 15(mm) diameter solid bar in chrome molybedenum steel(KS SCM440) to carbon steel(KS S45C) to investigate their mechanical properties. The main friction welding parameters were selected to endure good quality welds on the basis of visual examination, tensile tests, Vickers hardness surveys of the bond of area and H.A.Z and microstructure investigations. The specimens were tested as-welded and Post-Weld Heat Treated(PWHT). The tensile strength of the friction welded steel bars was increased up to 100% of the S45C base metal under the condition of all heating time. Optimal welding conditions were n=2,000(rpm), P{sub 1}=60(MPa), P{sub 2}=100(MPa), t{sub 1}=4(s), t{sub 2}=5(s) when the total upset length is 5.4 and 5.7(mm), respectively. The peak of hardness distribution of the friction welded joints can be eliminated by PWHT. Two different kinds of materials are strongly mixed to show a well-combined structure of macro-particles without any molten material and particle growth or any defects.

  15. Characteristics comparison of weld metal zones welded to cast and forged steels for piston crown material

    Science.gov (United States)

    Moon, Kyung-Man; Kim, Yun-Hae; Lee, Myeong-Hoon; Baek, Tae-Sil

    2015-03-01

    An optimum repair welding for the piston crown which is one of the engine parts exposed to the combustion chamber is considered to be very important to prolong the engine lifetime from an economical point of view. In this study, two types of filler metals such as 1.25Cr-0.5Mo, 0.5Mo were welded with SMAW method and the other two types of filler metals such as Inconel 625 and 718 were welded with GTAW method, respectively, and the used base metals were the cast and forged steels of the piston crown material. The weld metal zones welded with Inconel 625 and 718 filler metals exhibited higher corrosion resistance compared to 1.25Cr-0.5Mo and 0.5Mo filler metals. In particular, the weld metal zone welded with Inconel 718 and 0.5Mo, filler metals indicated the best and worst corrosion resistance, respectively. Consequently, it is suggested that the corrosion resistance of the weld metal zone surely depends on the chemical components of each filler metal and welding method irrespective of the types of piston crown material.

  16. Influence of welding passes on grain orientation – The example of a multi-pass V-weld

    International Nuclear Information System (INIS)

    Ye, Jing; Moysan, Joseph; Song, Sung-Jin; Kim, Hak-Joon; Chassignole, Bertrand; Gueudré, Cécile; Dupond, Olivier

    2012-01-01

    The accurate modelling of grain orientations in a weld is important, when accurate ultrasonic test predictions of a welded assembly are needed. To achieve this objective, Electricité de France (EDF) and the Laboratoire de Caractérisation Non Destructive (LCND) have developed a dedicated code, which makes use of information recorded in the welding procedure. Among the welding parameters recorded, although the order in which the welding passes are made is of primary importance in the welding process, this information is not always well known or accurately described. In the present paper we analyse in greater detail the influence of the order of welding passes, using data obtained from the Centre for Advanced Non Destructive Evaluation (CANDE), derived from a dissimilar metal weld (DMW) with buttering. Comparisons are made using grain orientation measurements on a macrograph. - Highlights: ► Influence of welding process on grain structure is studied using the MINA model. ► For the first time the importance of a slight slope of the layers is evaluated. ► Two orders of passes are compared for the modelling approach. ► A major effect is observed due to a change in the order of passes.

  17. Prediction Analysis of Weld-Bead and Heat Affected Zone in TIG welding using Artificial Neural Networks

    Science.gov (United States)

    Saldanha, Shamith L.; Kalaichelvi, V.; Karthikeyan, R.

    2018-04-01

    TIG Welding is a high quality form of welding which is very popular in industries. It is one of the few types of welding that can be used to join dissimilar metals. Here a weld joint is formed between stainless steel and monel alloy. It is desired to have control over the weld geometry of such a joint through the adjustment of experimental parameters which are welding current, wire feed speed, arc length and the shielding gas flow rate. To facilitate the automation of the same, a model of the welding system is needed. However the underlying welding process is complex and non-linear, and analytical methods are impractical for industrial use. Therefore artificial neural networks (ANN) are explored for developing the model, as they are well-suited for modelling non-linear multi-variate data. Feed-forward neural networks with backpropagation training algorithm are used, and the data for training the ANN taken from experimental work. There are four outputs corresponding to the weld geometry. Different training and testing phases were carried out using MATLAB software and ANN approximates the given data with minimum amount of error.

  18. Resistance welding equipment manufacturing capability for exports

    Energy Technology Data Exchange (ETDEWEB)

    Sastry, V.S.; Raju, Y.S.; Somani, A.K.; Setty, D.S.; Rameswara Raw, A.; Hermantha Rao, G.V.S.; Jayaraj, R.N. [Nuclear Fuel Complex, Dept. of Atomic Energy, Hyderbad (India)

    2010-07-01

    Indian Pressurised Heavy Water Reactor (PHWR) fuel bundle is fully welded and is unique in its design. Appendage welding, end closure welding, and end plate welding is carried out using resistance welding technique. Out of many joining processes available, resistance-welding process is reliable, environment friendly and best suitable for mass production applications. Nuclear Fuel Complex (NFC), an industrial unit is established in Hyderabad, under the aegis of the Dept of Atomic Energy to manufacture fuel for Pressurised Heavy Water Reactors. From inception, NFC has given importance for self-reliance and indigenization with respect to manufacturing process and equipment. Sintering furnaces, centreless grinders, appendage-welding machines, end-closure welding equipment and end-plate welding equipments, which were initially imported, are either indigenized or designed and manufactured in house. NFC has designed, manufactured a new appendage-welding machine for manufacturing 37 element fuel bundles. Recently NFC has bagged an order from IAEA through international bidding for design, manufacture, supply, erection and commissioning of end-closure welding equipment. The paper gives in detail the salient features of these welding equipment. (author)

  19. Feasibility of correlating V-Cr-Ti alloy weld strength with weld chemistry. CRADA final report

    International Nuclear Information System (INIS)

    Grossbeck, M.L.; Odom, R.W.

    1998-06-01

    The mechanical properties of refractory metals such as vanadium are determined to a large extent by the interstitial impurities in the alloy. In the case of welding, interstitial impurities are introduced in the welding process from the atmosphere and by dissolution of existing precipitates in the alloy itself. Because of the necessity of having an ultra-pure atmosphere, a vacuum chamber or a glove box is necessary. In the V-Cr-Ti system, the titanium serves as a getter to control the concentration of oxygen and nitrogen in solid solution in the alloy. In this project the secondary ion mass spectrometry (SIMS) technique was used to detect, measure, and map the spacial distribution of impurity elements in welds in the alloy V-4Cr-4Ti. An attempt was then made to correlate the concentrations and distributions of the impurities with mechanical properties of the welds. Mechanical integrity of the welds was determined by Charpy V-notch testing. Welds were prepared by the gas-tungsten-arc (GTA) method. Charpy testing established a correlation between weld impurity concentration and the ductile to brittle transition temperature (DBTT). Higher concentrations of oxygen resulted in a higher DBTT. An exception was noted in the case of a low-oxygen weld which had a high hydrogen concentration resulting in a brittle weld. The concentrations and distributions of the impurities determined by SIMS could not be correlated with the mechanical properties of the welds. This research supports efforts to develop fusion reactor first wall and blanket structural materials

  20. Aorto-enteric Fistula 15 Years After Uncomplicated Endovascular Aortic Repair with Unforeseen Onset of Endocarditis

    DEFF Research Database (Denmark)

    Kadhim, M M K; Rasmussen, J B G; Eiberg, J P

    2016-01-01

    Introduction Aorto-enteric fistula after endovascular aortic repair is an exceedingly rare but serious condition. Report A rare case of a fistula between the excluded aortic sac and the transverse colon 15 years after endovascular aortic repair is described. Onset was endocarditis without...... such as endocarditis, which in this case probably occurred as metastatic sepsis from endograft infection....

  1. Friction welding method

    International Nuclear Information System (INIS)

    Ishida, Ryuichi; Hatanaka, Tatsuo.

    1969-01-01

    A friction welding method for forming a lattice-shaped base and tie plate supporter for fuel elements is disclosed in which a plate formed with a concavity along its edge is pressure welded to a rotating member such as a boss by longitudinally contacting the projecting surfaces remaining on either side of the concavity with the rotating member during the high speed rotation thereof in the presence of an inert gas. Since only the two projecting surfaces of the plate are fused by friction to the rotary member, heat expansion is absorbed by the concavity to prevent distortion; moreover, a two point contact surface assures a stable fitting and promotes the construction of a rigid lattice in which a number of the abovementioned plates are friction welded between rotating members to form any desired complex arrangement. The inert has serves to protect the material quality of the contacting surfaces from air during the welding step. The present invention thus provides a method in which even Zircaloy may be friction welded in place of casting stainless steel in the construction of supporting lattices to thereby enhance neutron economy. (K. J. Owens)

  2. Endovascular management of an acquired aortobronchial fistula following aortic bypass for coarctation.

    LENUS (Irish Health Repository)

    O'Sullivan, Katie E

    2013-09-20

    Aortobronchial fistula (ABF) in the setting of aortic coarctation repair is very rare but uniformly fatal if untreated. Endovascular stenting of the descending aorta is now the first-choice approach for ABF presenting with haemoptysis and offers a less-invasive technique with improved outcomes, compared with open repair. We report a case of late ABF occurring following bypass for aortic coarctation. Management focused on two key manoeuvres: use of a covered endovascular stent to occlude the aortic bypass thus controlling the fistula and dilatation and stenting of native coarctation.

  3. Some studies on weld bead geometries for laser spot welding process using finite element analysis

    International Nuclear Information System (INIS)

    Siva Shanmugam, N.; Buvanashekaran, G.; Sankaranarayanasamy, K.

    2012-01-01

    Highlights: → In this study, a 2 kW Nd:YAG laser welding system is used to conduct laser spot welding trials. → The size and shape of the laser spot weld is predicted using finite element simulation. → The heat input is assumed to be a three-dimensional conical Gaussian heat source. → The result highlights the effect of beam incident angle on laser spot welds. → The achieved results of numerical simulation are almost identical with a real weldment. -- Abstract: Nd:YAG laser beam welding is a high power density welding process which has the capability to focus the beam to a very small spot diameter of about 0.4 mm. It has favorable characteristics namely, low heat input, narrow heat affected zone and lower distortions, as compared to conventional welding processes. In this study, finite element method (FEM) is applied for predicting the weld bead geometry i.e. bead length (BL), bead width (BW) and depth of penetration (DP) in laser spot welding of AISI 304 stainless steel sheet of thickness 2.5 mm. The input parameters of laser spot welding such as beam power, incident angle of the beam and beam exposure time are varied for conducting experimental trials and numerical simulations. Temperature-dependent thermal properties of AISI 304 stainless steel, the effect of latent heat of fusion, and the convective and radiative aspects of boundary conditions are considered while developing the finite element model. The heat input to the developed model is assumed to be a three-dimensional conical Gaussian heat source. Finite-element simulations of laser spot welding were carried out by using Ansys Parametric Design Language (APDL) available in finite-element code, ANSYS. The results of the numerical analysis provide the shape of the weld beads for different ranges of laser input parameters that are subsequently compared with the results obtained through experimentation and it is found that they are in good agreement.

  4. Microstructure and Mechanical Properties of an Ultrasonic Spot Welded Aluminum Alloy: The Effect of Welding Energy

    Directory of Open Access Journals (Sweden)

    He Peng

    2017-04-01

    Full Text Available The aim of this study is to evaluate the microstructures, tensile lap shear strength, and fatigue resistance of 6022-T43 aluminum alloy joints welded via a solid-state welding technique–ultrasonic spot welding (USW–at different energy levels. An ultra-fine necklace-like equiaxed grain structure is observed along the weld line due to the occurrence of dynamic crystallization, with smaller grain sizes at lower levels of welding energy. The tensile lap shear strength, failure energy, and critical stress intensity of the welded joints first increase, reach their maximum values, and then decrease with increasing welding energy. The tensile lap shear failure mode changes from interfacial fracture at lower energy levels, to nugget pull-out at intermediate optimal energy levels, and to transverse through-thickness (TTT crack growth at higher energy levels. The fatigue life is longer for the joints welded at an energy of 1400 J than 2000 J at higher cyclic loading levels. The fatigue failure mode changes from nugget pull-out to TTT crack growth with decreasing cyclic loading for the joints welded at 1400 J, while TTT crack growth mode remains at all cyclic loading levels for the joints welded at 2000 J. Fatigue crack basically initiates from the nugget edge, and propagates with “river-flow” patterns and characteristic fatigue striations.

  5. Kinematics effectively delineate accomplished users of endovascular robotics with a physical training model.

    Science.gov (United States)

    Duran, Cassidy; Estrada, Sean; O'Malley, Marcia; Lumsden, Alan B; Bismuth, Jean

    2015-02-01

    Endovascular robotics systems, now approved for clinical use in the United States and Europe, are seeing rapid growth in interest. Determining who has sufficient expertise for safe and effective clinical use remains elusive. Our aim was to analyze performance on a robotic platform to determine what defines an expert user. During three sessions, 21 subjects with a range of endovascular expertise and endovascular robotic experience (novices 20 hours) performed four tasks on a training model. All participants completed a 2-hour training session on the robot by a certified instructor. Completion times, global rating scores, and motion metrics were collected to assess performance. Electromagnetic tracking was used to capture and to analyze catheter tip motion. Motion analysis was based on derivations of speed and position including spectral arc length and total number of submovements (inversely proportional to proficiency of motion) and duration of submovements (directly proportional to proficiency). Ninety-eight percent of competent subjects successfully completed the tasks within the given time, whereas 91% of noncompetent subjects were successful. There was no significant difference in completion times between competent and noncompetent users except for the posterior branch (151 s:105 s; P = .01). The competent users had more efficient motion as evidenced by statistically significant differences in the metrics of motion analysis. Users with >20 hours of experience performed significantly better than those newer to the system, independent of prior endovascular experience. This study demonstrates that motion-based metrics can differentiate novice from trained users of flexible robotics systems for basic endovascular tasks. Efficiency of catheter movement, consistency of performance, and learning curves may help identify users who are sufficiently trained for safe clinical use of the system. This work will help identify the learning curve and specific movements that

  6. Friction Stir Welding Process: A Green Technology

    OpenAIRE

    Esther T. Akinlabi; Stephen A. Akinlabi

    2012-01-01

    Friction Stir Welding (FSW) is a solid state welding process invented and patented by The Welding Institute (TWI) in the United Kingdom in 1991 for butt and lap welding of metals and plastics. This paper highlights the benefits of friction stir welding process as an energy efficient and a green technology process in the field of welding. Compared to the other conventional welding processes, its benefits, typical applications and its use in joining similar and dissimilar materia...

  7. Imaging appearances and endovascular management of uncommon pseudoaneurysms

    International Nuclear Information System (INIS)

    Burli, P.; Winterbottom, A.P.; Cousins, C.; Appleton, D.S.; See, T.C.

    2008-01-01

    Pseudoaneurysms are uncommon and their aetiology is varied. They occur in numerous anatomical locations and present with a multitude of clinical presentations sometimes life-threatening. This review describes the causes, sites, and presentations of uncommon pseudoaneurysms, as well as illustrating their diagnostic appearances and endovascular management

  8. Welding skate with computerized controls

    Science.gov (United States)

    Wall, W. A., Jr.

    1968-01-01

    New welding skate concept for automatic TIG welding of contoured or double-contoured parts combines lightweight welding apparatus with electrical circuitry which computes the desired torch angle and positions a torch and cold-wire guide angle manipulator.

  9. Laser penetration spike welding: a welding tool enabling novel process and design opportunities

    Science.gov (United States)

    Dijken, Durandus K.; Hoving, Willem; De Hosson, J. Th. M.

    2002-06-01

    A novel method for laser welding for sheet metal. is presented. This laser spike welding method is capable of bridging large gaps between sheet metal plates. Novel constructions can be designed and manufactured. Examples are light weight metal epoxy multi-layers and constructions having additional strength with respect to rigidity and impact resistance. Its capability to bridge large gaps allows higher dimensional tolerances in production. The required laser systems are commercially available and are easily implemented in existing production lines. The lasers are highly reliable, the resulting spike welds are quickly realized and the cost price per weld is very low.

  10. The influence of the weld toe grinding and wig remelting weld toe rehabilitation techniques, on variable stresses, in case of cross fillet welds, reinforced with additional welding rows

    Directory of Open Access Journals (Sweden)

    Babis Claudiu

    2017-01-01

    Full Text Available Variable stresses where the load value varies between a maximum and a minimum value, or varies the position in time, cause after accumulating a large number of load cycles in those structures, the emergence of drug fatigue. Fatigue is characterized by failure on values of the applied stress from the load cycles, below the material flow, values which in case of static stress would not have caused problems. Knowing that the variable stressed structures are sensitive to stress concentrators, the paper aims to highlight the influence of two techniques to reduce stress concentrator weld toe grinding and WIG remelting weld toe, on the behavior of variable tensile test of cross corner welded specimens, reinforced with additional welding rows.

  11. The effect of flux on properties of weld in submerged arc welding with filler metal

    International Nuclear Information System (INIS)

    Fattahpour, Iran.

    1984-01-01

    In the submerged-arc welding, the electrode wire is shielded by a blanket of granular fusible material called a flux. This granular material, flux, must ensure the deposition of weld metal of given chemical composition and specified mechanical properties. The flux must also ensure stable burning of the welding arc and contribute to the formation of a dense weld of required shape and size, and free from pores, cracks and slag inclusions. As the deposited molten metal solidifies, the flux must form a slag crust, easily separable from the surface of the weld. This material must be of a certain chemical composition and possess definite physical properties, such as melting point, viscosity, bulk weight. The chemical composition of the flux is chosen, depending on the composition of the welded metal and electrode wire used. (Author)

  12. Repair welding of fusion reactor components

    International Nuclear Information System (INIS)

    Chin, B.A.

    1993-01-01

    Experiments have shown that irradiated Type 316 stainless steel is susceptible to heat-affected-zone (HAZ) cracking upon cooling when welded using the gas tungsten arc (GTA) process under lateral constraint. The cracking has been hypothesized to be caused by stress-assisted helium bubble growth and rupture at grain boundaries. This study utilized an experimental welding setup which enabled different compressive stresses to be applied to the plates during welding. Autogenous GTA welds were produced in Type 316 stainless steel doped with 256 appm helium. The application of a compressive stress, 55 MPa, during welding suppressed the previously observed catastrophic cracking. Detailed examinations conducted after welding showed a dramatic change in helium bubble morphology. Grain boundary bubble growth along directions parallel to the weld was suppressed. Results suggest that stress-modified welding techniques may be used to suppress or eliminate helium-induced cracking during joining of irradiated materials

  13. Evaluation of the AISI 904L Alloy Weld Overlays Obtained by GMAW and Electro-Slag Welding Processes

    Science.gov (United States)

    Jorge, Jorge C. F.; Meira, O. G.; Madalena, F. C. A.; de Souza, L. F. G.; Araujo, L. S.; Mendes, M. C.

    2017-05-01

    The use of superaustenitic stainless steels (SASS) as an overlay replacement for nickel-based alloys can be an interesting alternative for the oil and gas industries, due to its lower cost, when compared to superalloys. Usually, the deposition is made with several welding passes by using conventional arc welding processes, such as gas tungsten arc welding (GTAW) or gas metal arc welding (GMAW) processes. In this respect, electro-slag welding (ESW), which promotes high heat inputs and low dilution of the welds, can also be attractive for this application, as it provides a higher productivity, once only one layer is needed for the deposition of the minimum thickness required. The present work evaluates the behavior of an AISI 904L SASS weld overlay deposited on a carbon steel ASTM A516 Grade 70 by ESW and GMAW processes. Both as-welded and heat-treated conditions were evaluated and compared. A multipass welding by GMAW process with three layers and 48 passes was performed on 12.5 × 200 × 250 mm steel plates with average welding energy of 1.0 kJ/mm. For ESW process, only one layer was deposited on 50 × 400 × 400 mm steel plates with average welding energy of 11.7 kJ/mm. After welding, a post-weld heat treatment (PWHT) at 620 °C for 10 h was performed in half of the steel plate, in order to allow the comparison between this condition and the as-welded one. For both processes, the austenitic microstructure of the weld deposits was characterized by optical microscopy and scanning electron microscopy with electron backscatter diffraction. A low proportion of secondary phases were observed in all conditions, and the PWHT did not promote significant changes on the hardness profile. Martensite for GMAW process and bainite for ESW process were the microstructural constituents observed at the coarse grain heat-affected zone, due to the different cooling rates. For ESW process, no evidences of partially diluted zones were found. As a consequence of the microstructural

  14. Real time computer controlled weld skate

    Science.gov (United States)

    Wall, W. A., Jr.

    1977-01-01

    A real time, adaptive control, automatic welding system was developed. This system utilizes the general case geometrical relationships between a weldment and a weld skate to precisely maintain constant weld speed and torch angle along a contoured workplace. The system is compatible with the gas tungsten arc weld process or can be adapted to other weld processes. Heli-arc cutting and machine tool routing operations are possible applications.

  15. Effect of the weld groove shape and pass number on residual stresses in butt-welded pipes

    International Nuclear Information System (INIS)

    Sattari-Far, I.; Farahani, M.R.

    2009-01-01

    This study used finite element techniques to analyze the thermo-mechanical behaviour and residual stresses in butt-welded pipes. The residual stresses were also measured in some welds by using the Hole-Drilling method. The results of the finite element analysis were compared with experimentally measured data to evaluate the accuracy of the finite element modelling. Based on this study, a finite element modelling procedure with reasonable accuracy was developed. The developed FE modelling was used to study the effects of weld groove shape and weld pass number on welding residual stresses in butt-welded pipes. The hoop and axial residual stresses in pipe joints of 6 and 10 mm thickness of different groove shapes and pass number were studied. It is shown that these two parameters may have significant effects on magnitude and distribution of residual stresses in welded pipes.

  16. Development of Weld Metal Microstructures in Pulsed Laser Welding of Duplex Stainless Steel

    Science.gov (United States)

    Mirakhorli, F.; Malek Ghaini, F.; Torkamany, M. J.

    2012-10-01

    The microstructure of the weld metal of a duplex stainless steel made with Nd:YAG pulsed laser is investigated at different travel speeds and pulse frequencies. In terms of the solidification pattern, the weld microstructure is shown to be composed of two distinct zones. The presence of two competing heat transfer channels to the relatively cooler base metal and the relatively hotter previous weld spot is proposed to develop two zones. At high overlapping factors, an array of continuous axial grains at the weld centerline is formed. At low overlapping factors, in the zone of higher cooling rate, a higher percentage of ferrite is transformed to austenite. This is shown to be because with extreme cooling rates involved in pulsed laser welding with low overlapping, the ferrite-to-austenite transformation can be limited only to the grain boundaries.

  17. Effect of post-weld aging treatment on mechanical properties of Tungsten Inert Gas welded low thickness 7075 aluminium alloy joints

    International Nuclear Information System (INIS)

    Temmar, M.; Hadji, M.; Sahraoui, T.

    2011-01-01

    Highlights: → The effects of post-weld aging treatment on the properties of joints is studied. → The post-weld aging treatment increases the tensile strength of TIG welded joints. → The strengthening is due to a balance of dissolution, reversion and precipitation. → Simple post-weld aging at 140 o C enhances the properties of the welded joints. -- Abstract: This paper reports the influence of post-weld aging treatment on the microstructure, tensile strength, hardness and Charpy impact energy of weld joints low thickness 7075 T6 aluminium alloy welded by Tungsten Inert Gas (TIG). Hot cracking occurs in aluminium welds when high levels of thermal stress and solidification shrinkage are present while the weld is undergoing various degrees of solidification. Weld fusion zones typically exhibit microstructure modifications because of the thermal conditions during weld metal solidification. This often results in low weld mechanical properties and low resistance to hot cracking. It has been observed that the mechanical properties are very sensitive to microstructure of weld metal. Simple post-weld aging treatment at 140 o C applied to the joints is found to be beneficial to enhance the mechanical properties of the welded joints. Correlations between microstructures and mechanical properties were discussed.

  18. Windows Security patch required

    CERN Multimedia

    3004-01-01

    This concerns Windows PCs (XP, 2000, NT) which are NOT centrally managed at CERN for security patches, e.g. home PCs, experiment PCs, portables,... A security hole which can give full privileges on Windows systems needs to be URGENTLY patched. Details of the security hole and hotfix are at: http://cern.ch/it-div/news/hotfix-MS03-026.asp http://www.microsoft.com/technet/security/bulletin/MS03-026.asp

  19. Advances in solar cell welding technology

    Energy Technology Data Exchange (ETDEWEB)

    Chidester, L.G.; Lott, D.R.

    1982-09-01

    In addition to developing the rigid substrate welded conventional cell panels for an earlier U.S. flight program, LMSC recently demonstrated a welded lightweight array system using both 2 x 4 and 5.9 x 5.9 cm wraparound solar cells. This weld system uses infrared sensing of weld joint temperature at the cell contact metalization interface to precisely control weld energy on each joint. Modules fabricated using this weld control system survived lowearth-orbit simulated 5-year tests (over 30,000 cycles) without joint failure. The data from these specifically configured modules, printed circuit substrate with copper interconnect and dielectric wraparound solar cells, can be used as a basis for developing weld schedules for additional cell array panel types.

  20. Welding abilities of UFG metals

    Science.gov (United States)

    Morawiński, Łukasz; Chmielewski, Tomasz; Olejnik, Lech; Buffa, Gianluca; Campanella, Davide; Fratini, Livan

    2018-05-01

    Ultrafine Grained (UFG) metals are characterized by an average grain size of welded joints with similar properties to the base of UFG material are crucial for the production of finished engineering components. Conventional welding methods based on local melting of the joined edges cannot be used due to the UFG microstructure degradation caused by the heat occurrence in the heat affected zone. Therefore, the possibility of obtaining UFG materials joints with different shearing plane (SP) positions by means of friction welded processes, which do not exceed the melting temperature during the process, should be investigated. The article focuses on the Linear Friction Welding (LFW) method, which belongs to innovative welding processes based on mixing of the friction-heated material in the solid state. LFW is a welding process used to joint bulk components. In the process, the friction forces work due to the high frequency oscillation and the pressure between the specimens is converted in thermal energy. Character and range of recrystallization can be controlled by changing LFW parameters. Experimental study on the welded UFG 1070 aluminum alloy by means of FLW method, indicates the possibility of reducing the UFG structure degradation in the obtained joint. A laboratory designed LFW machine has been used to weld the specimens with different contact pressure and oscillation frequency.