WorldWideScience

Sample records for endoscopically compatible fiber

  1. Technical compatibility and safety of glass fiber in battery separators

    Energy Technology Data Exchange (ETDEWEB)

    Bender, R. [Schuller International, Toledo, OH (United States); Versen, R. [Schuller International, Littleton, CO (United States)

    1995-07-01

    Nonwovens comprised of glass fibers are both compatible with the relatively harsh chemical environment in lead acid batteries, and yet are safe to handle. The health and safety of glass fibers may seem confusing from a regulatory viewpoint, but are in fact highly tested and well understood scientifically to not cause respiratory disease. Nonwoven separators made from glass fibers are well situated to withstand scientific scrutiny in these times of suspicion of negative health effects ranging from second-hand smoke to tap water. This paper examines technical compatibility of the glass fibers in the battery, the health and safety aspects of glass fibers, and governmental and regulatory interpretation of studies.

  2. Dark-field illuminated reflectance fiber bundle endoscopic microscope

    Science.gov (United States)

    Liu, Xuan; Huang, Yong; Kang, Jin U.

    2011-04-01

    We propose a reflectance fiber bundle microscope using a dark-field illumination configuration for applications in endoscopic medical imaging and diagnostics. Our experiment results show that dark-field illumination can effectively suppress strong specular reflection from the proximal end of the fiber bundle. We realized a lateral resolution of 4.4 μm using the dark-field illuminated fiber bundle configuration. To demonstrate the feasibility of using the system to study cell morphology, we obtained still and video images of two thyroid cancer cell lines. Our results clearly allow differentiation of different cancer cell types.

  3. Study on the compatibility of unbleached and bleached bamboo-fiber with LLDPE matrix

    CSIR Research Space (South Africa)

    Kumar, S

    2010-10-01

    Full Text Available of employing natural fibers is that these are biodegradable and renewable, and exhibit low cost, low density and high toughness. However, the low compatibility between fibers and polymer matrix generally leads to weak mechanical performances, limiting... of the compatibility of the fibers with the matrix. This study gives us the idea of using the bleached fiber for the preparation of the composites. Keywords LLDPE � Compatibility � Bamboo-fiber � Bleaching � Thermal characterization Introduction Polymer...

  4. All fiber based multispeckle modality endoscopic system for imaging medical cavities

    Science.gov (United States)

    Murukeshan, V. M.; Sujatha, N.

    2007-05-01

    Disease detection in body cavities, such as the detection of abnormal growths in the colon path, has been illustrated here using an image fiber guided catheter based multispeckle modality endoscopic system. An all fiber-optic approach for the illumination and imaging of the inner cavity walls is adopted here. An endoscope probe to carry the illumination fibers as well as the imaging lens-image fiber unit is designed and custom fabricated in order to operate the probe in its various direction sensitive configurations. This is facilitated by the selection of suitable optical elements such as beam combiner and biprism at the probe proximal end. Experimental investigations were carried out using the endoscope system employing phantom model of colon as the test specimen that has normal and abnormal (representing growth) regions and the obtained results indicated the system effectiveness in identifying the abnormal growths at an early stage.

  5. Ex-vivo endoscopic laryngeal cancer imaging using two forward-looking fiber optic scanning endoscope probes

    Science.gov (United States)

    Cernat, R.; Tatla, T.; Pang, J.-Y.; Tadrous, P. J.; Gelikonov, G.; Gelikonov, V.; Zhang, Y. Y.; Bradu, A.; Li, X. D.; Podoleanu, A. G.

    2012-12-01

    Larynx cancer is one of the most common primary head and neck cancers. For early-stage laryngeal cancer, both surgery and radiotherapy are effective treatment modalities, offering a high rate of local control and cure. Optical coherence tomography (OCT) is an established non-invasive optical biopsy method, capable of imaging ranges of 2- 3 mm into tissue. By using the principles of low coherence light interferometry, OCT can be used to distinguish normal from unhealthy laryngeal mucosa in patients. Two forward-looking endoscope OCT probes of different sizes in a sweeping frequency OCT (SS-OCT) configuration were compared in terms of their performances for ex-vivo laryngeal cancer imaging. The setup configuration of the first OCT probe unit was designed and constructed at the Institute of Applied Physics RAS, Russia (diameter of 1.9 mm and the rigid part at the distal end is 13 mm long). The second OCT endoscope probe was constructed at the Department of Biomedical Engineering at Johns Hopkins University, USA, using a tubular piezoelectric actuator with quartered electrodes in combination with a resonant fiber cantilever (diameter of 2.4 mm, and rigid part of 45 mm). Cross-sectional images of laryngeal lesions using the two OCT configurations were aquired and compared with OCT images obtained in a 1310 nm SS-OCT classical non-endoscopic system. The work presented here is an intermediate step in our research towards in-vivo endoscopic laryngeal cancer imaging.

  6. High-performance silica/silica fiber for endoscopic applications

    Science.gov (United States)

    McCann, Brian P.

    1993-05-01

    Silica-core/silica-clad fibers have become very popular tools for a variety of therapeutic and diagnostic applications. Two types of conventional silica/silica fibers having acrylate and polyimide coatings are reviewed. The properties of dual-waveguide silica/silica fiber are discussed; and the superior bend performance with this design is presented. Silicone/nylon and hard-fluoropolymer/TefzelTM dual-coated fibers are included as the dual-waveguide samples. Sample fibers of each of the four coating types were manufactured into 400/440 micrometers size, 0.22 NA fiber.

  7. Interferometric microstructured polymer optical fiber ultrasound sensor for optoacoustic endoscopic imaging in biomedical applications

    Science.gov (United States)

    Gallego, Daniel; Sáez-Rodríguez, David; Webb, David; Bang, Ole; Lamela, Horacio

    2014-05-01

    We report a characterization of the acoustic sensitivity of microstructured polymer optical fiber interferometric sensors at ultrasonic frequencies from 100kHz to 10MHz. The use of wide-band ultrasonic fiber optic sensors in biomedical ultrasonic and optoacoustic applications is an open alternative to conventional piezoelectric transducers. These kind of sensors, made of biocompatible polymers, are good candidates for the sensing element in an optoacoustic endoscope because of its high sensitivity, its shape and its non-brittle and non-electric nature. The acoustic sensitivity of the intrinsic fiber optic interferometric sensors depends strongly of the material which is composed of. In this work we compare experimentally the intrinsic ultrasonic sensitivities of a PMMA mPOF with other three optical fibers: a singlemode silica optical fiber, a single-mode polymer optical fiber and a multimode graded-index perfluorinated polymer optical fiber.

  8. Interferometric microstructured polymer optical fiber ultrasound sensor for optoacoustic endoscopic imaging in biomedical applications

    DEFF Research Database (Denmark)

    Gallego, Daniel; Sáez-Rodríguez, David; Webb, David

    2014-01-01

    We report a characterization of the acoustic sensitivity of microstructured polymer optical fiber interferometric sensors at ultrasonic frequencies from 100kHz to 10MHz. The use of wide-band ultrasonic fiber optic sensors in biomedical ultrasonic and optoacoustic applications is an open alternative...... to conventional piezoelectric transducers. These kind of sensors, made of biocompatible polymers, are good candidates for the sensing element in an optoacoustic endoscope because of its high sensitivity, its shape and its non-brittle and non-electric nature. The acoustic sensitivity of the intrinsic fiber optic...... interferometric sensors depends strongly of the material which is composed of. In this work we compare experimentally the intrinsic ultrasonic sensitivities of a PMMA mPOF with other three optical fibers: a singlemode silica optical fiber, a single-mode polymer optical fiber and a multimode graded...

  9. Demonstration of full 4×4 Mueller polarimetry through an optical fiber for endoscopic applications.

    Science.gov (United States)

    Manhas, Sandeep; Vizet, Jérémy; Deby, Stanislas; Vanel, Jean-Charles; Boito, Paola; Verdier, Mireille; De Martino, Antonello; Pagnoux, Dominique

    2015-02-09

    A novel technique to measure the full 4 × 4 Mueller matrix of a sample through an optical fiber is proposed, opening the way for endoscopic applications of Mueller polarimetry for biomedical diagnosis. The technique is based on two subsequent Mueller matrices measurements: one for characterizing the fiber only, and another for the assembly of fiber and sample. From this differential measurement, we proved theoretically that the polarimetric properties of the sample can be deduced. The proof of principle was experimentally validated by measuring various polarimetric parameters of known optical components. Images of manufactured and biological samples acquired by using this approach are also presented.

  10. Resilience of disposable endoscope optical fiber properties after repeat sterilization.

    Science.gov (United States)

    Johnson, Matthew T; Khemees, Tariq A; Knudsen, Bodo E

    2013-01-01

    The PolyScope(®) (Lumenis, Santa Clara, CA) is a disposable flexible ureteroscope composed of a single-use flexible catheter and a reusable fiber optic bundle. We tested the resilience of the optical properties of the reusable optical fiber after repeat sterilization. Optical properties evaluated were resolution, distortion, and light transmission. Two different optical fibers were tested, one for each sterilization method. Measurements on each fiber were obtained at baseline and were repeated after each set of 10 sterilization cycles for a total of 100 cycles. To measure resolution, the 1951 USAF Contrast Resolution Chart Target was used to subjectively identify the clearest image on the grid by two different operators. To measure distortion, three images of the distortion grid target were captured with a digital camera and analyzed within Image Pro Plus Software. Light transmission was measured using a digital light meter at 50% and 100% transmission. There was no significant difference in resolution after 100 sterilization cycles between either Steris or Sterrad NX. Distortion changed by 8.7% and 11.2% for Steris and Sterrad NX, respectively. For Steris at 100% light transmission, baseline was 59 foot-candles and this increased to 85 foot-candles after 100 cycles. For Sterrad NX at 100% light transmission, baseline was 50 foot-candles and this increased to 92 foot-candles after 100 cycles. Results were similar at 50%. There was no significant difference between groups at 50%, 100%, or between sterilization modalities. The PolyScope fiber optic bundle appears durable after 100 cycles of sterilization with either Steris or Sterrad NX.

  11. Delivery of ultrashort spatially focused pulses through a multimode fiber for two photon endoscopic imaging

    Science.gov (United States)

    Morales-Delgado, Edgar E.; Papadopoulos, Ioannis N.; Farahi, Salma; Psaltis, Demetri; Moser, Christophe

    2015-06-01

    Due to their high number of supported modes, multimode optical fibers carry large amount of spatio-temporal information. However, propagation of a light pulse through a multimode optical fiber suffers from spatial distortions due to superposition of the various exited modes and from time broadening due to modal dispersion. Here, we present a method based on digital phase conjugation to selectively excite specific optical fiber modes in a multimode fiber that follow similar optical paths as they travel through the fiber. In this way, they can be made to interfere constructively at the fiber output to generate an ultrashort spatially focused pulse. The excitation of a limited number of modes limits modal dispersion, allowing the transmission of an ultrashort pulse. We also show that the short spatially focused pulse can be scanned digitally without movable elements. We experimentally demonstrate that the pulse at the output of the multimode fiber generate a two-photon signal. We show delivery of a 1550 nm pulse with 500 fs duration, spatially focused to a spot size of 7 micrometers, through a 30 cm long, 200 micrometers core multimode step-index fiber. We show how this technique is applied to endoscopic two-photon imaging.

  12. Development of a fiber based Raman probe compatible with interventional magnetic resonance imaging

    Science.gov (United States)

    Ashok, Praveen C.; Praveen, Bavishna B.; Rube, Martin; Cox, Benjamin; Melzer, Andreas; Dholakia, Kishan

    2014-02-01

    Raman spectroscopy has proven to be a powerful tool for discriminating between normal and abnormal tissue types. Fiber based Raman probes have demonstrated its potential for in vivo disease diagnostics. Combining Raman spectroscopy with Magnetic Resonance Imaging (MRI) opens up new avenues for MR guided minimally invasive optical biopsy. Although Raman probes are commercially available, they are not compatible with a MRI environment due to the metallic components which are used to align the micro-optic components such as filters and lenses at the probe head. Additionally they are not mechanically compatible with a typical surgical environment as factors such as sterility and length of the probe are not addressed in those designs. We have developed an MRI compatible fiber Raman probe with a disposable probe head hence maintaining sterility. The probe head was specially designed to avoid any material that would cause MR imaging artefacts. The probe head that goes into patient's body had a diameter <1.5 mm so that it is compatible with biopsy needles and catheters. The probe has been tested in MR environment and has been proven to be capable of obtaining Raman signal while the probe is under real-time MR guidance.

  13. Use of an Endoscope Compatible Probe to Detect Colonic Dysplasia with Fourier Transform Infrared (FTIR) Spectroscopy

    Science.gov (United States)

    Mackanos, Mark A.; Hargrove, John T.; Du, Christine B.; Friedland, Shai; Soetikno, Roy M.; Contag, Christopher H.; Wolters, Rolf; Arroyo, May R.; Crawford, James M.; Wang, Thomas D.

    2011-01-01

    FTIR spectroscopy is sensitive to the molecular composition of tissue and has the potential to identify pre-malignant tissue (dysplasia) as an adjunct to endoscopy. We demonstrate collection of mid-infrared absorption spectra with a silver halide (AgCl0.4Br0.6) optical fiber and use spectral pre-processing to identify optimal sub-ranges that classify colonic mucosa as normal, hyperplasia, or dysplasia. We collected spectra (n = 83) in the 950 to 1800 cm−1 regime on biopsy specimens obtained from human subjects (n = 37). Subtle differences in the magnitude of the absorbance peaks at specific wavenumbers were observed. The best double binary algorithm for distinguishing normal-versus-dysplasia and hyperplasia-versus-dysplasia was determined from an exhaustive search of spectral intervals and pre-processing techniques. Partial least squares discriminant analysis was used to classify the spectra using a leave-one-subject-out cross-validation strategy. The results were compared with histology reviewed independently by two gastrointestinal pathologists. The optimal thresholds identified resulted in an overall sensitivity, specificity, accuracy, and positive predictive value of 96%, 92%, 93%, and 82%, respectively. These results indicated that mid-infrared absorption spectra collected remotely with an optical fiber can be used to identify colonic dysplasia with high accuracy, suggesting that continued development of this technique for the early detection of cancer is promising. PMID:19725718

  14. Optical Fiber-Based MR-Compatible Sensors for Medical Applications: An Overview

    Science.gov (United States)

    Taffoni, Fabrizio; Formica, Domenico; Saccomandi, Paola; Di Pino, Giovanni; Schena, Emiliano

    2013-01-01

    During last decades, Magnetic Resonance (MR)—compatible sensors based on different techniques have been developed due to growing demand for application in medicine. There are several technological solutions to design MR-compatible sensors, among them, the one based on optical fibers presents several attractive features. The high elasticity and small size allow designing miniaturized fiber optic sensors (FOS) with metrological characteristics (e.g., accuracy, sensitivity, zero drift, and frequency response) adequate for most common medical applications; the immunity from electromagnetic interference and the absence of electrical connection to the patient make FOS suitable to be used in high electromagnetic field and intrinsically safer than conventional technologies. These two features further heightened the potential role of FOS in medicine making them especially attractive for application in MRI. This paper provides an overview of MR-compatible FOS, focusing on the sensors employed for measuring physical parameters in medicine (i.e., temperature, force, torque, strain, and position). The working principles of the most promising FOS are reviewed in terms of their relevant advantages and disadvantages, together with their applications in medicine. PMID:24145918

  15. Performance Evaluation of an MRI-Compatible Pre-Clinical PET System Using Long Optical Fibers

    Science.gov (United States)

    Mackewn, Jane E.; Halsted, Philip; Charles-Edwards, Geoffrey; Page, Richard; Totman, John J.; Sunassee, Kavitha; Strul, Daniel; Hallett, William A.; Jauregui-Osoro, Maite; Liepins, Peter; Williams, Steven C. R.; Schaeffter, Tobias; Keevil, Stephen F.; Marsden, Paul K.

    2010-06-01

    We have designed and constructed an MR-compatible PET system for fully simultaneous PET/MR studies of small animals. The scanner uses long optical fibers to distance the magnetic field sensitive PET PMTs from the high magnetic field at the center of an MR scanner. It is a single slice system with an inner diameter of 7 cm. A full evaluation of the performance of the PET system and the results of an MR compatibility assessment in a Philips Achieva whole body 3 T MRI scanner are presented. The reconstructed resolution of the PET scanner is 1.5 mm at the center falling to 2.5 mm at the edge of the field of view; the system sensitivity is 0.95%; the count rate is linear up to an activity of 6 MBq ( 4 kcps) and the scatter fraction is 42% which can be reduced to 26% using MR-compatible gamma shields. Simultaneous PET/MR images of phantoms and a mouse have been acquired. The system is highly MR compatible, as demonstrated here, showing no degradation in performance of either the MR or PET system in the presence of the other modality. The system will be used to demonstrate novel pre-clinical applications of simultaneous PET/MR.

  16. Influence of coupling agent in compatibility of post-consumer HDPE in thermoplastic composites reinforced with eucalyptus fiber

    OpenAIRE

    Catto,André Luis; Stefani,Bruno Vicari; Ribeiro,Vanda Ferreira; Santana,Ruth Marlene Campomanes

    2014-01-01

    This study investigates the feasibility of using recycled high density polyethylene (HDPE) and wood fiber from species Eucalyptus grandis (EU) to manufacture experimental composite panels. The use of maleated polyethylene as coupling agent (CA) improved the compatibility between the fiber and plastic matrix. The mechanical properties of the resultant composites were compared with polymer with and without compatibilizer. The influence of the coupling agent (CA) in the polymer matrices and comp...

  17. Iterative l(1)-min algorithm for fixed pattern noise removal in fiber-bundle-based endoscopic imaging.

    Science.gov (United States)

    Liu, Xuan; Zhang, Lijun; Kirby, Mitchell; Becker, Richard; Qi, Shaohai; Zhao, Feng

    2016-04-01

    In this study, we developed a signal processing method for fixed pattern noise removal in fiber-bundle-based endoscopic imaging. We physically acquired the fixed pattern of the fiber bundle and used it as a prior image in an l1 norm minimization (l1-min) algorithm. We chose an iterative shrinkage thresholding algorithm for l1 norm minimization. In addition to fixed pattern noise removal, this method also improved image contrast while preserving spatial resolution. The effectiveness of this method was demonstrated on images obtained from a dark-field illuminated reflectance fiber-optic microscope (DRFM). The iterative l1-min algorithm presented in this paper, in combination with the DRFM system that we previously developed, enables high-resolution, high-sensitivity, intrinsic-contrast, and in situ cellular imaging which has great potential in clinical diagnosis and biomedical research.

  18. fMRI-compatible registration of jaw movements using a fiber-optic bend sensor

    Directory of Open Access Journals (Sweden)

    Peter Sörös

    2010-03-01

    Full Text Available A functional magnetic resonance imaging (fMRI-compatible fiber-optic bend sensor was investigated to assess whether the device could be used effectively to monitor opening and closing of the jaw during an fMRI experiment at 3 T. In contrast to surface electromyography, a bend sensor fixed to the chin of the participant is fast and easy to use and is not affected by strong electromagnetic fields. Bend sensor recordings are characterized by high validity (compared with concurrent video recordings of mouth opening and high reliability (comparing 2 independent measurements. The results of this study indicate that a bend sensor is able to record the opening and closing of the jaw associated with different overt speech conditions (producing the utterances /a/, /pa/, /pataka/ and the opening of the mouth without speech production. Data post-processing such as filtering was not necessary. There are several potential applications for bend sensor recordings of speech-related jaw movements. First, bend sensor recordings are a valuable tool to assess behavioral performance, such as response latencies, accuracies, and completion times, which is particularly important in children, seniors, or patients with various neurological or psychiatric conditions. Second, the timing information provided by bend sensor data may improve the predicted hemodynamic response that is used for fMRI analysis based on the general linear model (GLM. Third, bend sensor recordings may be included in GLM analyses not for statistical contrast purposes, but as a covariate of no interest, accounting for part of the data variance to model fMRI artifacts due to motion outside the field of view.

  19. Spectral and fluorescence lifetime endoscopic system using a double-clad photonic crystal fiber.

    Science.gov (United States)

    Ibrahim, A; Poulon, F; Melouki, F; Zanello, M; Varlet, P; Habert, R; Devaux, B; Kudlinski, A; Abi Haidar, D

    2016-11-15

    We present a customized small-core double-clad photonic crystal fiber for spectral and fluorescence lifetime measurements of human samples. In this Letter, the new fiber has been characterized on different fluorophores and samples of human brain tumor; a comparison to a bi-fiber homemade system and a commercial fiber probe was made.

  20. Naturally Compatible: Starch Acetate/Cellulosic Fiber Composites. I. Processing and Properties

    DEFF Research Database (Denmark)

    Nättinen, Kalle; Hyvärinen, Sari; Joffe, Roberts

    2010-01-01

    Composite compounds based on hemp and flax fibers in triethyl citrate plasticized starch acetate were prepared by melt processing. For better properties and processability, compounds with plasticizer contents in the range 20-35 wt% were screened. Composites were prepared with fiber contents up...... to 50 wt%. The composite mechanical properties were measured from injection molded test specimens. A Young's modulus of 8.3 GPa and stress at maximum load of 51 MPa were obtained with 40 wt% flax fiber in a plasticized starch acetate with 20 wt% triethyl citrate. Decreasing the plasticizer...

  1. Semi-resonant operation of a fiber-cantilever piezotube scanner for stable optical coherence tomography endoscope imaging.

    Science.gov (United States)

    Moon, Sucbei; Lee, Sang-Won; Rubinstein, Marc; Wong, Brian J F; Chen, Zhongping

    2010-09-27

    A forward-view optical coherence tomography (OCT) scanning catheter has been developed based on a fiber-cantilever piezotube scanner by using a semi-resonant scan strategy for a better scan performance. A compact endoscope catheter was fabricated by using a tubular piezoelectric actuator with quartered electrodes in combination with a resonant fiber cantilever. A cantilever weight was attached to the fiber cantilever to reduce the resonance frequency down to 63 Hz, well in the desirable range for Fourier-domain OCT. The resonant-cantilever scanner was driven at semi-resonance frequencies that were well out of the resonance peak but within a range of partial resonance. This driving strategy has been found to minimize the phase difference between the two scan axes for a better scan stability against environmental perturbations as well as for a driving simplicity. By driving the two axes at slightly different frequencies, a low-order Lissajous pattern has been obtained for a 2D area scan. 3D OCT images have been successfully acquired in an acquisition time of 1.56 seconds for a tomogram volume of 2.2 × 2.2 × 2.1 mm(3). They were reconstructed without any scan calibration by extracting the scan timing from the image data. In addition, it has been found that the Lissajous scan strategy provides a means to compensate the relative axial motion of a sample for a correct imaged morphology.

  2. [Study on interface compatibility and fracture resistance of polyglycidyl methacrylate pre-impregnated quartz fiber reinforced polymethyl methacrylate denture base resin].

    Science.gov (United States)

    Xu, Ming-ming; Yan, Xu; Deng, Xu-ling

    2015-02-18

    To explore the reinforcement of polyglycidyl methacrylate (PGMA) pre-impregnated quartz fiber mesh in denture base materials by investigation of interface compatibility and fracture resistance. 1-layer, 2-layer, 3-layer PGMA pre-impregnated quartz fiber meshes, electrolyzed cobalt-chromium alloy mesh and cobalt-chromium alloy mesh conditioned by metal primer were integrated in polymethyl methacrylate (PMMA) resin by sandwich embedding method. Block samples of 5 groups were prepared (40 mm×15 mm×2 mm). Fracture resistance was determined in a 3-point bending test at 2 mm/min. Scanning electron microscope (SEM), micrographs were taken from the fractured surfaces to analyze the bonding interface compatibility. The group of 3-layer PGMA pre-impregnated quartz fiber mesh presented the highest elastic modulus of 6 406 MPa and flexural strength of 227 MPa among the five groups, while the 1-layer and 2-layer expressed the similar elastic modulus and flexural strength to the pure PMMA group. The metal groups demonstrated better mechanical properties, while the metal surface conditioner played much better. The metal surface conditioner pre-impregnated cobalt-chromium alloy and PGMA pre-impregnated quartz fiber mesh showed compatible interface with PMMA. The mechanical properties were improved by the increasing of the fiber by adding the more meshed. Although the benign interface did help the compatibility, the quantity of the fibers played an important role in the strength.

  3. Effect of multimodal coupling in imaging micro-endoscopic fiber bundle on optical coherence tomography.

    Science.gov (United States)

    Han, Jae-Ho; Kang, Jin U

    2012-01-14

    The effect of higher order modes in fiber bundle imager-based optical coherence tomography (OCT) has been theoretically modeled using coupled fiber mode analysis ignoring the polarization and core size variation in order to visualize the pure effect of multimodal coupling of the imaging bundle. In this model, the optical imaging fiber couples several higher order modes in addition to the fundamental one due to its high numerical aperture for achieving light confinement to the single core pixel. Those modes become evident in a distance domain using A-mode (depth) OCT based on a mirror sample experiment where multiple peaks are generated by the spatial convolution and coherence function of the light source. The distance between the peaks corresponding to each mode can be estimated by considering the effective indices of coupled (guided) modes obtained from numerically solving the fiber mode characteristics equations and the fiber length. The results have been compared for various types (fiber dimensions and wavelengths) and lengths of fibers, which have mode separation of 715 μm (1404 μm) and 764 μm (1527 μm) for the measurement and analysis, respectively in a 152.5 mm (305 mm)-long imaging fiber.

  4. Penetrometer compatible, fiber-optic sensor for continuous monitoring of chlorinated hydrocarbons -- field test results

    Energy Technology Data Exchange (ETDEWEB)

    Milanovich, F.P.; Brown, S.B.; Colston, B.W. Jr.

    1993-04-01

    We have developed and field tested a fiber optic chemical sensor for use in environmental monitoring and remediation. The principle of detection is colorimetric and is based on an irreversible chemical reaction between a specific reagent and the target compound. The formation of reaction products are monitored remotely with optical fibers. Successive or on-demand measurements are made possible with a reagent reservoir and a miniature pumping system. The sensor has been evaluated against gas chromatography standards and has demonstrated accuracy and sensitivity (>5ppb w/w) sufficient for the environmental monitoring of the contaminants triceoroethlyene (TCE) and chloroform. The sensor system can be used for bench-top analyses or for in-situ measurements such as groundwater and vadose monitoring wells or in Penetrometry mediated placements.

  5. Integrated and miniaturized endoscopic devices for use during high power infrared fiber laser surgery

    Science.gov (United States)

    Wilson, Christopher Ryan

    The Thulium Fiber Laser (TFL) is currently being studied as a potential alternative to the conventional, solid-state Holmium:YAG laser (Ho:YAG) for the treatment of kidney stones. The TFL is an ideal candidate to replace the Ho:YAG for laser lithotripsy due to a higher absorption coefficient in water of the emitted wavelength, an ability to operate at high pulse rates, and a near single mode, Gaussian spatial beam profile. The higher absorption of the TFL wavelength by water translates to a decrease in ablation threshold by a factor of four. High pulse rate operation allows higher ablation rates than the Ho:YAG, thus decreasing operation time necessary to ablate the urinary stone. The Gaussian spatial beam profile allows the TFL to couple higher laser power into smaller optical fibers than those currently being used for Ho:YAG lithotripsy. This decrease in fiber diameter translates into a potential decrease in the size of ureteroscope working channel, higher saline irrigation rates for improved visibility and safety, and may also extend to a decrease in overall ureteroscope diameter. Furthermore, the improved spatial beam profile reduces the risk of damage to the input end of the fiber. Therefore, the trunk fiber, minus the distal fiber tip, may be preserved and re-used, resulting in significant cost savings. This thesis details rapid TFL lithotripsy at high pulse rates up to 500 Hz, both with and without the aid of a stone retrieval basket, in order to demonstrate the TFL's superior ablation rates over the Ho:YAG. Collateral damage testing of the TFL effect on the ureter wall and Nitinol stone baskets were conducted to ensure patient safety for future clinical use. Proximal fiber end damage testing was conducted to demonstrate fiber preservation, critical for permanent fiber integration. Optical fibers were fitted with fabricated hollow steel tips and integrated with stone retrieval baskets for testing. Ball tipped optical fibers were tested to maintain ablation

  6. An fMRI-compatible multi-configurable handheld response system using an intensity-modulated fiber-optic sensor.

    Science.gov (United States)

    Jarrahi, Behnaz; Wanek, Johann; Mehnert, Ulrich; Kollias, Spyros

    2013-01-01

    Functional magnetic resonance imaging (fMRI) data should be interpreted in combination and in the context of relevant behavioral measurements. However, the strong magnetic environment of MRI scanner and the supine position of participants in the scanner significantly limit how participants' behavioral responses are recorded. This paper presents the design of a low-cost handheld response system (HRS) with a multi-configurable optomechanical design that utilizes a reflective-type intensity modulated fiber-optic sensor (FOS) and a programmable visual interface to accurately gather participants' behavioral responses during an fMRI experiment. Considering the effects of an input unit design on the participants' performance efficiency across age groups and physical and neurological (dis)ability, the optomechanical system is designed to provide flexibility in the range of an input module with easy change-out feature. Specifically, the input unit can be configured as a binary module such as push buttons or as an analog input device including a scrolling wheel, and one-dimensional joystick (lever arm). To achieve MRI-compatibility, all parts of the unit that are used inside the scanner bore are built from nonferromagnetic and off-the-shelf plastic materials. The MRI compatibility was evaluated on a 3.0 Tesla MRI scanner running echo planar imaging (EPI) and the average time-variant signal-to-noise ratio (tSNR) loss is limited to 2%.

  7. Miniaturized fiber-optic ultrasound probes for endoscopic tissue analysis by micro-opto-mechanical technology.

    Science.gov (United States)

    Vannacci, E; Belsito, L; Mancarella, F; Ferri, M; Veronese, G P; Roncaglia, A; Biagi, E

    2014-06-01

    A new Micro-Opto-Mechanical System (MOMS) technology for the fabrication of optoacoustic probes on optical fiber is presented. The technology is based on the thermoelastic emission of ultrasonic waves from patterned carbon films for generation and on extrinsic polymer Fabry-Perot acousto-optical transducers for detection, both fabricated on miniaturized single-crystal silicon frames used to mount the ultrasonic transducers on the tip of an optical fiber. Thanks to the fabrication process adopted, high miniaturization levels are reached in the MOMS devices, demonstrating fiber-optic emitters and detectors with minimum diameter around 350 and 250 μm respectively. A thorough functional testing of the ultrasound emitters mounted on 200 and 600 μm diameter optical fibers is presented, in which the fiber-optic emitter with a diameter of 200 μm shows generated acoustic pressures with peak-to-peak value up to 2.8 MPa with rather flat emission spectra extended beyond 150 MHz. The possibility to use the presented optoacoustic sources in conjunction with the fiber-optic acousto-optical detectors within a minimally invasive probe is also demonstrated by successfully measuring the ultrasonic echo reflected from a rigid surface immersed in water with various concentration of scatterers. The resulting spectra highlight the possibility to discriminate the effects due to frequency selective attenuation in a very wide range of frequencies within a biological medium using the presented fiber-optic probes.

  8. Feedforward Neural Network for Force Coding of an MRI-Compatible Tactile Sensor Array Based on Fiber Bragg Grating

    Directory of Open Access Journals (Sweden)

    Paola Saccomandi

    2015-01-01

    Full Text Available This work shows the development and characterization of a fiber optic tactile sensor based on Fiber Bragg Grating (FBG technology. The sensor is a 3 × 3 array of FBGs encapsulated in a PDMS compliant polymer. The strain experienced by each FBG is transduced into a Bragg wavelength shift and the inverse characteristics of the sensor were computed by means of a feedforward neural network. A 21 mN RMSE error was achieved in estimating the force over the 8 N experimented load range while including all probing sites in the neural network training procedure, whereas the median force RMSE was 199 mN across the 200 instances of a Monte Carlo randomized selection of experimental sessions to evaluate the calibration under generalized probing conditions. The static metrological properties and the possibility to fabricate sensors with relatively high spatial resolution make the proposed design attractive for the sensorization of robotic hands. Furthermore, the proved MRI-compatibility of the sensor opens other application scenarios, such as the possibility to employ the array for force measurement during functional MRI-measured brain activation.

  9. PPLN-based photon-pair source compatible with solid state quantum memories and telecom optical fibers

    Science.gov (United States)

    Latypov, I. Z.; Shkalikov, A. V.; Akat'ev, D. O.; Kalachev, A. A.

    2017-06-01

    We report on the realization of a tunable source of correlated photon pairs compatible with telecommunication networks and quantum memories involving dielectric crystals doped by Nd3+ ions. The source is based on spontaneous parametric down-conversion in a 25 mm periodically poled lithium niobate crystal pumped by 532 nm cw laser. Spectral and correlation characteristics of the corresponding heralded single-photon source compatible with quantum memories are presented.

  10. Endoscopic ultrasound

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/007646.htm Endoscopic ultrasound To use the sharing features on this page, please enable JavaScript. Endoscopic ultrasound is a type of imaging test. It is ...

  11. Thulium fiber laser for the use in low-invasive endoscopic and robotic surgery of soft biological tissues

    Science.gov (United States)

    Michalska, M.; Brojek, W.; Rybak, Z.; Sznelewski, P.; Mamajek, M.; Gogler, S.; Swiderski, J.

    2016-12-01

    An all-fiber, diode-pumped, continuous-wave Tm3+-doped fiber laser operated at a wavelength of 1.94 μm was developed. 37.4 W of output power with a slope efficiency as high as 57% with respect to absorbed pump power at 790 nm was demonstrated. The laser output beam quality factor M2 was measured to be 1.2. The output beam was very stable with power fluctuations soft biological tissues.

  12. Fiber

    Science.gov (United States)

    ... fiber you get from the food. Fiber-rich foods offer health benefits when eaten raw or cooked. Alternative Names Diet - fiber; Roughage; Bulk; Constipation - fiber Patient Instructions Constipation - ...

  13. Relationship between swallow-specific quality of life and fiber-optic endoscopic evaluation of swallowing findings in patients with head and neck cancer.

    Science.gov (United States)

    Florie, Michelle; Baijens, Laura; Kremer, Bernd; Kross, Kenneth; Lacko, Martin; Verhees, Femke; Winkens, Bjorn

    2016-04-01

    The purpose of this study was to determine the relationship between swallow-specific quality of life (QOL) using the MD Anderson Dysphagia Inventory (MDADI) and the swallowing function using a standardized fiber-optic endoscopic evaluation of swallowing (FEES) protocol in patients with dysphagia with head and neck cancer. Sixty-three patients with dysphagia and head and neck cancer were enrolled in the study. Patients completed the MDADI questionnaire and underwent a standardized FEES examination. Ordinal FEES variables were measured. Descriptive statistics and 1-way analysis of variance tests were carried out. For all FEES variables, the observer agreement level was sufficient (kappa ≥0.7).These preliminary results show statistically significant mean differences of MDADI subscales between the ordinal scale levels for several FEES variables. The MDADI questionnaire can be used to assess the impact of dysphagia on the patients' health-related QOL. Despite clear trends, it remains unclear if the MDADI questionnaire can be used as an indicator for the severity of oropharyngeal dysphagia. © 2015 Wiley Periodicals, Inc. Head Neck 38: E1848-E1856, 2016. © 2015 Wiley Periodicals, Inc.

  14. Endoscopic calcaneoplasty

    NARCIS (Netherlands)

    van Dijk, C. N.; van Dyk, G. E.; Scholten, P. E.; Kort, N. P.

    2001-01-01

    Endoscopic calcaneoplasty offers access to the retrocalcaneal space, thereby making it possible to remove inflamed retrocalcaneal bursa as well as the posterosuperior part of the calcaneus in applicable cases of painful hindfoot. In this study, endoscopic calcaneoplasty was performed in 21

  15. Endoscopic tympanoplasty

    Directory of Open Access Journals (Sweden)

    Abdulvahap Akyigit

    2017-06-01

    Full Text Available Middle ear surgery is usually performed using a surgical microscope. Initially, in otorhinolaryngology practice, endoscopes were used for paranasal sinus surgeries. It was only later that they were applied in the area of otology. In otologic surgeries, endoscopes were first used to visualize the middle ear, before being used to assist with visualization of instruments during cholesteatoma surgeries, although they are still not used alone in various otologic surgeries. As in other surgical fields, there is also a trend towards minimally invasive intervention in the field of otorhinolaryngology. Smaller incisions performed under the guidance of endoscopes are preferred over conventional large incisions. Using this approach, improved outcomes can be achieved and postoperative morbidities can be reduced. In addition, the outcomes of grafts performed using the endoscopic approach are similar to that achieved by the microscopic approach. Therefore, endoscopic ear surgery implementations are becoming increasingly popular.

  16. Endoscopic retrograde cholangiopancreatography and endoscopic ...

    African Journals Online (AJOL)

    An approach to suspected gallstone pancreatitis'based on endoscopic retrograde cholangiopancreatography (ERCP) and endoscopic sphincterotomy (ES) was adopted in 1976 and was followed in 29 patients. ERCp became the routine method of early biliary tract assessment when gallstone pancreatitis was suspected on ...

  17. Endoscopic retrograde cholangiopancreatography and endoscopic ...

    African Journals Online (AJOL)

    1991-01-05

    Jan 5, 1991 ... An approach to suspected gallstone pancreatitis'based on endoscopic retrograde cholangiopancreatography (ERCP) and e'ndoscopic sphincterotomy (ES) was adopted in 1976 and was followed in 29 patients. ERCp became the routine method of early biliary tract assessment when gallstone pancreatitis.

  18. Miniaturized Fourier-plane fiber scanner for OCT endoscopy

    Science.gov (United States)

    Vilches, Sergio; Kretschmer, Simon; Ataman, Çağlar; Zappe, Hans

    2017-10-01

    A forward-looking endoscopic optical coherence tomography (OCT) probe featuring a Fourier-plane fiber scanner is designed, manufactured and characterized. In contrast to common image-plane fiber scanners, the Fourier-plane scanner is a telecentric arrangement that eliminates vignetting and spatial resolution variations across the image plane. To scan the OCT beam in a spiral pattern, a tubular piezoelectric actuator is used to resonate an optical fiber bearing a collimating GRIN lens at its tip. The free-end of the GRIN lens sits at the back focal plane of an objective lens, such that its rotation replicates the beam angles in the collimated region of a classical telecentric 4f optical system. Such an optical arrangement inherently has a low numerical aperture combined with a relatively large field-of-view, rendering it particularly useful for endoscopic OCT imaging. Furthermore, the optical train of the Fourier-plane scanner is shorter than that of a comparable image-plane scanner by one focal length of the objective lens, significantly shortening the final arrangement. As a result, enclosed within a 3D printed housing of 2.5 mm outer diameter and 15 mm total length, the developed probe is the most compact forward-looking endoscopic OCT imager to date. Due to its compact form factor and compatibility with real-time OCT imaging, the developed probe is also ideal for use in the working channel of flexible endoscopes as a potential optical biopsy tool.

  19. Fiber

    Science.gov (United States)

    ... white toast. Lunch and Dinner: Make sandwiches with whole-grain breads (rye, oat, or wheat) instead of white. Make a fiber-rich sandwich with whole-grain bread, peanut butter, and bananas. Use whole-grain spaghetti ...

  20. Endoscopic dacryocystorhinostomy

    Directory of Open Access Journals (Sweden)

    Milojević Milanko

    2010-01-01

    Full Text Available Background/Aim. Intensive epiphora (lacrimal apparatus disease can make difficult daily routine and cause ocular refraction disturbances. In most cases ethiology is unknown, rarely occurs after nose surgical procedures, face fractures, in Wegener granulomatosis, sarcoidosis and malignancies. The aim of this study was to evaluate efficacy of endonasal endoscopic surgical procedure with the conventional surgical instruments in treatment of nasolacrimal obstructions. Methods. This retrospective study included 12 female patients with endonasal endoscopic surgical procedure from Otorhinological and Ophtalmological Departments of Military Medical Academy, Belgrade from September 2007 to April 2009. Preoperative nasal endoscopy was performed in order to reveal concomitant pathological conditions and anatomic anomalies which could make surgical procedure impossible. Computerized tomography was performed only in suspect nose diseases. Surgical endonasal endoscopic procedure was performed by otorhinolaryngologist and ophtalmologist in all patients. The patients had regular controls from 2 to 20 months. Results. A total of 12 female patients, age 34-83 years, were included in our study. Epiphora was a dominant symptom in all patients. In two patients deviation of nasal septum was found, and in other one conha bulosa at the same side as chronic dacryocystitis. All patients were subjected to endonasal dacryocystorhinostomy (DCR by endoscopic surgical technique using conventional instruments. Concomitantly with DCR septoplastics in two patients and lateral lamictetomy in one patient were performed. There were no complications intraoperatively as well as in the immediate postoperative course. In two patients the need for reoperation occurred. Conclusion. Endoscopic DCR is minimally invasive and efficacious procedure for nasolacrymal obstructions performed by otorhinolaryngologist and ophtalmologist. Postoperative recovery is very fast.

  1. Evaluation of compatibility and thermal properties of PP composites incorporated with Moringa oleifera fibers; Avaliacao das propriedades termicas e compatibilidade de compositos de PP incorporados com fibras de Moringa oleifera

    Energy Technology Data Exchange (ETDEWEB)

    Sa, Daniel M.; Novack, Katia M., E-mail: danielmirandaufop@yahoo.com.br, E-mail: knovack@iceb.ufop.br [Dept. de Quimica (DEQUI) - Universidade Federal de Ouro Preto (UFOP), Ouro Preto, MG (Brazil); Botaro, Vagner R., E-mail: vagner@ufscar.br [UFSCar/Sorocaba, SP (Brazil)

    2011-07-01

    The 70s, marked by the oil crisis led to knowledge about environmental problems due to indiscriminate use of nonrenewable resources. The automobile manufacturers have sought to obtain new materials for building more efficient cars, which favored the development of high-performance polymers. One alternative was the use of agents of natural reinforcements in composites manufacturing. In this work, composites were prepared using polypropylene as matrix and as a reinforcing agent of natural seed pods of Moringa oleifera in different proportions, treated with sodium hydroxide solution 10%. These composites were characterized by TGA, DSC, XRD, MEV and water absorption. It was found that increasing the amount of fiber in the polymer matrix did not change significantly the morphology and amount of water absorption of the samples. It was also observed that the addition of larger amounts of fibers decreases the degradation temperature of the samples and their melting temperatures shifts to lower temperatures, indicative of compatibility matrix / reinforcement agents. (author)

  2. Endoscopic case

    OpenAIRE

    Pereira, Fernando

    2017-01-01

    We present the case of a ten-year-old female patient referred to Gastroenterolgy consultation for abdominal pain and cramping, usually worse after eating, recurring diarrhoea, hypochromic and microcytic anaemia with low serum iron and ferritin levels. Moderate to severe Crohn’s disease of the terminal ileum e right colon (L3) was diagnosed, based on endoscopic image and biopsy. The patient was treated with prednisone and azathioprine, but after one year of treatment she was steroids dependent...

  3. Endoscopic case

    Directory of Open Access Journals (Sweden)

    Fernando Pereira

    2017-01-01

    Full Text Available We present the case of a ten-year-old female patient referred to Gastroenterolgy consultation for abdominal pain and cramping, usually worse after eating, recurring diarrhoea, hypochromic and microcytic anaemia with low serum iron and ferritin levels. Moderate to severe Crohn’s disease of the terminal ileum e right colon (L3 was diagnosed, based on endoscopic image and biopsy. The patient was treated with prednisone and azathioprine, but after one year of treatment she was steroids dependent and treatment was switched to infliximab. One year after beginning this treatment, the patient achieved remission (clinical and laboratorial parameters. A control colonoscopy showed mucosal healing with scars and deformation with stenosis of ileocecal valve (Figures 1-2. Surgical intervention will be probably necessary in near future.

  4. Water Fibers

    CERN Document Server

    Douvidzon, Mark L; Martin, Leopoldo L; Carmon, Tal

    2016-01-01

    Fibers constitute the backbone of modern communication and are used in laser surgeries; fibers also genarate coherent X-ray, guided-sound and supercontinuum. In contrast, fibers for capillary oscillations, which are unique to liquids, were rarely considered in optofluidics. Here we fabricate fibers by water bridging an optical tapered-coupler to a microlensed coupler. Our water fibers are held in air and their length can be longer than a millimeter. These hybrid fibers co-confine two important oscillations in nature: capillary- and electromagnetic-. We optically record vibrations in the water fiber, including an audio-rate fundamental and its 3 overtones in a harmonic series, that one can hear in soundtracks attached. Transforming Micro-Electro-Mechanical-Systems [MEMS] to Micro-Electro-Capillary-Systems [MECS], boosts the device softness by a million to accordingly improve its response to minute forces. Furthermore, MECS are compatible with water, which is a most important liquid in our world.

  5. Testing "Compatibility Testing."

    Science.gov (United States)

    Robins, Elliot; Huston, Ted L.

    Most models of marital choice are attempts to explain choices within the field of available eligibles. The essence of compatibility testing is that people select their mates by evaluating the match between psychological characteristics after sorting the available field on the basis of social characteristics. A compatibility model seems to require…

  6. Hepatic applications of endoscopic ultrasound

    DEFF Research Database (Denmark)

    Srinivasan, Indu; Tang, Shou-Jiang; Vilmann, Andreas S

    2015-01-01

    The diagnosis and staging of various gastrointestinal malignancies have been made possible with the use of endoscopic ultrasound, which is a relatively safe procedure. The field of endoscopic ultrasound is fast expanding due to advancements in therapeutic endoscopic ultrasound. Though various...... of endoscopic ultrasound, thus not only providing an overview of utilization of endoscopic ultrasound in various liver conditions but also speculating its future role....

  7. Supercontinuum as a light source for miniaturized endoscopes

    OpenAIRE

    Lu, M. K.; Lin, H. Y.; Hsieh, C C; Kao, F. J.

    2016-01-01

    In this work, we have successfully implemented supercontinuum based illumination through single fiber coupling. The integration of a single fiber illumination with a miniature CMOS sensor forms a very slim and powerful camera module for endoscopic imaging. A set of tests and in vivo animal experiments are conducted accordingly to characterize the corresponding illuminance, spectral profile, intensity distribution, and image quality. The key illumination parameters of the supercontinuum, inclu...

  8. Role of Rigid Endoscopic Detorsion in the Management of Sigmoid ...

    African Journals Online (AJOL)

    mesenteric attachment secondary to chronic constipation, irregular bowel habits or a bulky, high fiber diet ... no features of bowel ischemia noted, a rectal tube was inserted and secured using a 1.0 non-absorbable ... SV, after unsuccessful endoscopic detortion, or when features suggestive of bowel ischemia (dark mucosa.

  9. Endoscopic ultrasound-guided endoscopic transmural drainage of pancreatic pseudocysts

    OpenAIRE

    César Vivian Lopes; Christian Pesenti; Erwan Bories; Fabrice Caillol; Marc Giovannini

    2008-01-01

    BACKGROUND: Surgery is the traditional treatment for symptomatic pancreatic pseudocysts, but the morbidity is still too high. Minimally invasive endoscopic approaches have been encouraged. AIMS: To evaluate the efficacy of endoscopic ultrasound-guided endoscopic transmural drainage of pancreatic pseudocysts. METHODS: From January, 2003 to August, 2006, 31 consecutive symptomatic patients submitted to 37 procedures at the same endoscopic unit were retrospectively analysed. Chronic and acute pa...

  10. Endoscopic neck surgery

    Directory of Open Access Journals (Sweden)

    Chowbey P

    2007-01-01

    Full Text Available Endoscopic surgery in the neck was attempted in 1996 for performing parathyroidectomy. A similar surgical technique was used for performing thyroidectomy the following year. Most commonly reported endoscopic neck surgery studies in literature have been on thyroid and parathyroid glands. The approaches are divided into two types i.e., the total endoscopic approach using CO2 insufflation and the video-assisted approach without CO2 insufflation. The latter approach has been reported more often. The surgical access (port placements may vary-the common sites are the neck, anterior chest wall, axilla, and periareolar region. The limiting factors are the size of the gland and malignancy. Few reports are available on endoscopic resection for early thyroid malignancy and cervical lymph node dissection. Endoscopic neck surgery has primarily evolved due to its cosmetic benefits and it has proved to be safe and feasible in suitable patients with thyroid and parathyroid pathologies. Application of this technique for approaching other cervical organs such as the submandibular gland and carotid artery are still in the early experimental phase.

  11. Sterilization of endoscopic instruments.

    Science.gov (United States)

    Sabnis, Ravindra B; Bhattu, Amit; Vijaykumar, Mohankumar

    2014-03-01

    Sterilization of endoscopic instruments is an important but often ignored topic. The purpose of this article is to review the current literature on the sterilization of endoscopic instruments and elaborate on the appropriate sterilization practices. Autoclaving is an economic and excellent method of sterilizing the instruments that are not heat sensitive. Heat sensitive instruments may get damaged with hot sterilization methods. Several new endoscopic instruments such as flexible ureteroscopes, chip on tip endoscopes, are added in urologists armamentarium. Many of these instruments are heat sensitive and hence alternative efficacious methods of sterilization are necessary. Although ethylene oxide and hydrogen peroxide are excellent methods of sterilization, they have some drawbacks. Gamma irradiation is mainly for disposable items. Various chemical agents are widely used even though they achieve high-level disinfection rather than sterilization. This article reviews various methods of endoscopic instrument sterilization with their advantages and drawbacks. If appropriate sterilization methods are adopted, then it not only will protect patients from procedure-related infections but prevent hypersensitive allergic reactions. It will also protect instruments from damage and increase its longevity.

  12. Endoscopic submucosal dissection

    DEFF Research Database (Denmark)

    Pimentel-Nunes, Pedro; Dinis-Ribeiro, Mário; Ponchon, Thierry

    2015-01-01

    UNLABELLED: This Guideline is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). The Grading of Recommendations Assessment, Development, and Evaluation (GRADE) system 1 2 was adopted to define the strength of recommendations and the quality of evidence. MAIN...... RECOMMENDATIONS: 1 ESGE recommends endoscopic en bloc resection for superficial esophageal squamous cell cancers (SCCs), excluding those with obvious submucosal involvement (strong recommendation, moderate quality evidence). Endoscopic mucosal resection (EMR) may be considered in such lesions when...... they are smaller than 10 mm if en bloc resection can be assured. However, ESGE recommends endoscopic submucosal dissection (ESD) as the first option, mainly to provide an en bloc resection with accurate pathology staging and to avoid missing important histological features (strong recommendation, moderate quality...

  13. High numerical aperture imaging by using multimode fibers with micro-fabricated optics

    KAUST Repository

    Bianchi, Silvio

    2014-01-01

    Controlling light propagation into multimode optical fibers through spatial light modulators provides highly miniaturized endoscopes and optical micromanipulation probes. We increase the numerical aperture up to nearly 1 by micro-optics fabricated on the fiber-end.

  14. Olecranon extrabursal endoscopic bursectomy.

    Science.gov (United States)

    Tu, Chen G; McGuire, Duncan T; Morse, Levi P; Bain, Gregory I

    2013-09-01

    Olecranon bursitis is a common clinical problem. It is often managed conservatively because of the high rates of wound complications with the conventional open surgical technique. Conventional olecranon bursoscopy utilizes an arthroscope and an arthroscopic shaver, removing the bursa from inside-out. We describe an extrabursal endoscopic technique where the bursa is not entered but excised in its entirety under endoscopic vision. A satisfactory view is obtained with less morbidity than the open method, while still avoiding a wound over the sensitive point of the olecranon.

  15. Electromagnetic compatibility engineering

    CERN Document Server

    Ott, Henry W

    2009-01-01

    Praise for Noise Reduction Techniques IN electronic systems ""Henry Ott has literally 'written the book' on the subject of EMC. . . . He not only knows the subject, but has the rare ability to communicate that knowledge to others.""-EE Times Electromagnetic Compatibility Engineering is a completely revised, expanded, and updated version of Henry Ott's popular book Noise Reduction Techniques in Electronic Systems. It reflects the most recent developments in the field of electromagnetic compatibility (EMC) and noise reduction¿and their practical applications t

  16. Application of wireless electrical non-fiberoptic endoscope: Potential benefit and limitation in endoscopic surgery.

    Science.gov (United States)

    Chen, Chih-Hao; Chang, Ho; Liu, Tsang-Pai; Huang, Tun-Sung; Chen, Chao-Hung

    2015-07-01

    Conventional rigid endoscope requires a bundle of optic fibers for illumination and a set of camera for viewing body cavity. The design is bulky in the hand-held part and the laterally positioned optic fibers may hinder manipulation of instruments, especially in single port surgery. We designed a simplified unit to replace conventional endoscope. We used an independent front image sensor along with six light emitting diode crystals. A wireless module working in 2.4 GHz and its antenna were integrated into the hand-help part. Two 800 mA batteries were used for power supply. The study was tested in two 35 kg pigs. Some simple thoracoscopic and laparoscopic operations were simulated to test the reliability and surgeon's acceptability. Signal Noise ratio can be controlled well in the setting of the operative room. Signal transmission was influenced significantly when covered by damped gauze or drape. The best quality of wireless transmission is through line-of-sight. Dropping frame is less than 1 frame per second in 99% time period during the test. Wireless modules in the design of rigid endoscope may be a plausible option with good acceptability. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  17. Development of a nonlinear fiber-optic spectrometer for human lung tissue exploration.

    Science.gov (United States)

    Peyrot, Donald A; Lefort, Claire; Steffenhagen, Marie; Mansuryan, Tigran; Ducourthial, Guillaume; Abi-Haidar, Darine; Sandeau, Nicolas; Vever-Bizet, Christine; Kruglik, Sergei G; Thiberville, Luc; Louradour, Frédéric; Bourg-Heckly, Geneviève

    2012-05-01

    Several major lung pathologies are characterized by early modifications of the extracellular matrix (ECM) fibrillar collagen and elastin network. We report here the development of a nonlinear fiber-optic spectrometer, compatible with an endoscopic use, primarily intended for the recording of second-harmonic generation (SHG) signal of collagen and two-photon excited fluorescence (2PEF) of both collagen and elastin. Fiber dispersion is accurately compensated by the use of a specific grism-pair stretcher, allowing laser pulse temporal width around 70 fs and excitation wavelength tunability from 790 to 900 nm. This spectrometer was used to investigate the excitation wavelength dependence (from 800 to 870 nm) of SHG and 2PEF spectra originating from ex vivo human lung tissue samples. The results were compared with spectral responses of collagen gel and elastin powder reference samples and also with data obtained using standard nonlinear microspectroscopy. The excitation-wavelength-tunable nonlinear fiber-optic spectrometer presented in this study allows performing nonlinear spectroscopy of human lung tissue ECM through the elastin 2PEF and the collagen SHG signals. This work opens the way to tunable excitation nonlinear endomicroscopy based on both distal scanning of a single optical fiber and proximal scanning of a fiber-optic bundle.

  18. Introduction to electromagnetic compatibility

    Science.gov (United States)

    Paul, Clayton R.

    A formal and extensive treatment of electromagnetic compatibility (EMC) is presented. Basic principles are reviewed in detail, including reasons for EMC in electronic design. Also discussed are: nonideal behavior of components, signal spectra, radiated emission and susceptibility, conducted emissions and susceptibility, crosstalk, shielding, electrostatic discharge, and system design for EMC.

  19. Electromagnetic compatibility overview

    Science.gov (United States)

    Davis, K. C.

    1980-01-01

    An assessment of the electromagnetic compatibility impact of the Satellite Power System is discussed. The discussion is divided into two parts: determination of the emission expected from SPS including their spatial and spectral distributions, and evaluation of the impact of such emissions on electromagnetic systems including considerations of means for mitigating effects.

  20. Technicalities of endoscopic biopsy

    NARCIS (Netherlands)

    Tytgat, G. N.; Ignacio, J. G.

    1995-01-01

    Despite the wealth of biopsy forceps currently available, it is obvious that there are sufficient drawbacks and shortcomings to reconsider the overall design of the endoscopic biopsy depth, the short lifespan of reusable forceps, damage to the working channel, excessive time consumption, cleaning

  1. Robotic flexible endoscope

    NARCIS (Netherlands)

    Ruiter, Jeroen

    2013-01-01

    In flexible endoscopy a flexible tube with a steerable camera is used to inspect the internal patient tracts and to perform small surgical interventions. In current practice the physician is faced with usability problems. Often assistance is required to manipulate the flexible endoscope and the

  2. Evolving endoscopic surgery.

    Science.gov (United States)

    Sakai, Paulo; Faintuch, Joel

    2014-06-01

    Since the days of Albukasim in medieval Spain, natural orifices have been regarded not only as a rather repugnant source of bodily odors, fluids and excreta, but also as a convenient invitation to explore and treat the inner passages of the organism. However, surgical ingenuity needed to be matched by appropriate tools and devices. Lack of technologically advanced instrumentation was a strong deterrent during almost a millennium until recent decades when a quantum jump materialized. Endoscopic surgery is currently a vibrant and growing subspecialty, which successfully handles millions of patients every year. Additional opportunities lie ahead which might benefit millions more, however, requiring even more sophisticated apparatuses, particularly in the field of robotics, artificial intelligence, and tissue repair (surgical suturing). This is a particularly exciting and worthwhile challenge, namely of larger and safer endoscopic interventions, followed by seamless and scarless recovery. In synthesis, the future is widely open for those who use together intelligence and creativity to develop new prototypes, new accessories and new techniques. Yet there are many challenges in the path of endoscopic surgery. In this new era of robotic endoscopy, one will likely need a virtual simulator to train and assess the performance of younger doctors. More evidence will be essential in multiple evolving fields, particularly to elucidate whether more ambitious and complex pathways, such as intrathoracic and intraperitoneal surgery via natural orifice transluminal endoscopic surgery (NOTES), are superior or not to conventional techniques. © 2014 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  3. TRANSNASAL ENDOSCOPIC DACRYOCYSTORHINOSTOMY

    Directory of Open Access Journals (Sweden)

    Brigita Drnovšek Olup

    2004-05-01

    Full Text Available Background. We present our experience with transnasal endoscopic dacryocystorhinostomy.Patients and methods. We treated 95 patients with lacrimal duct insufficiency from June 2000 to February 2003. The most frequent cause of nasolacrimal duct obstruction was chronic inflammation. We inserted a light probe through the inferior canalliculus to transilluminate the area of the lacrimal sac. We anaemized the region over the lacrimal sac and the attachment of the middle nasal concha and corrected nasal septum deviation were indicated. We coagulated and removed the mucosa over the transilluminated area, the bony wall and the medial portion of the lacrimal sac. After haemostasis, we placed silicone tubes through both canalliculi and fixed its ends with metallic clips. We finally introduced a Merocel tampon in the middle nasal meatus for two days. The silicone tubes remained in place for 3 to 4 months.Results. We observed no serious complications. The silicone tubes remained in place for 3 to 4 months. Follow up period ranged from 8 to 40 months. We noticed recurrence of symptoms in seven patients.Conclusions. Transnasal endoscopic DCR is a contribution to the development of endoscopic surgery technique. Its success rate is comparable to or even better than external DCR, according to other and our own study. Transnasal endoscopic DCR is a simple and successful procedure and well tolerated by the patients.

  4. Endoscopic treatment of obesity

    Science.gov (United States)

    Swidnicka-Siergiejko, Agnieszka; Wróblewski, Eugeniusz; Dabrowski, Andrzej

    2011-01-01

    BACKGROUND: The increasing incidence of obesity and overweight among children and adolescents will be reflected by the imminent increase in the number of obese patients who require more definitive methods of treatment. There is great interest in new, safe, simple, nonsurgical procedures for weight loss. OBJECTIVE: To provide an overview of new endoscopic methods for the treatment of obesity. METHODS: An English-language literature search on endoscopic interventions, endoscopically placed devices and patient safety was performed in the MEDLINE and Cochrane Library databases. RESULTS: The literature search yielded the following weight loss methods: space-occupying devices (widely used), gastric capacity reduction, modifying gastric motor function and malabsorptive procedures. A commercially available intragastric balloon was the most commonly used device for weight loss. In specific subgroups of patients, it improved quality of life, decreased comorbidities and served as a bridge to surgery. More evidence regarding the potential benefits and safety of other commercially available intragastric balloons is needed to clarify whether they are superior to the most commonly used one. Moreover, early experiences with transoral gastroplasty, the duodenaljejunal bypass sleeve and an adjustable, totally implantable intragastric prosthesis, indicate that they may be viable options for obesity treatment. Other agents, such as botulinum toxin and a device known as the ‘butterfly’, are currently at the experimental stage. CONCLUSION: New endoscopic methods for weight loss may be valuable in the treatment of obesity; however, more clinical experience and technical improvements are necessary before implementing their widespread use. PMID:22059171

  5. Diode laser and endoscopic laser surgery.

    Science.gov (United States)

    Sullins, Kenneth E

    2002-05-01

    Two functionally important differences exist between the diode laser and the carbon dioxide (CO2) laser (used more commonly in small animal surgery). Diode laser energy is delivered through a quartz fiber instead of being reflected through an articulated arm or waveguide. Quartz fibers are generally more flexible and resilient than waveguides and can be inserted through an endoscope for minimally invasive procedures. Laser-tissue interaction is the other significant difference. The CO2 laser is completely absorbed by water, which limits the effect to visible tissue. The diode wavelength is minimally absorbed by water and may affect tissue as deep as 10 mm below the surface in the free-beam mode. With proper respect for the tissue effect, these differences can be used to the advantage of the patient.

  6. Optical fiber smartphone spectrometer.

    Science.gov (United States)

    Hossain, Md Arafat; Canning, John; Cook, Kevin; Jamalipour, Abbas

    2016-05-15

    An optical fiber-based smartphone spectrometer incorporating an endoscopic fiber bundle is demonstrated. The endoscope allows transmission of the smartphone camera LED light to a sample, removing complications from varying background illumination. The reflected spectra collected from a surface or interface is dispersed onto the camera CMOS using a reflecting diffraction grating. A spectral resolution as low as δλ∼2.0  nm over a bandwidth of Δλ∼250  nm is obtained using a slit width, ωslit=0.7  mm. The instrument has vast potential in a number of industrial applications including agricultural produce analysis. Spectral analysis of apples shows straightforward measurement of the pigments anthocyanins, carotenoid, and chlorophyll, all of which decrease with increasing storage time.

  7. Automated endoscope reprocessors.

    Science.gov (United States)

    Desilets, David; Kaul, Vivek; Tierney, William M; Banerjee, Subhas; Diehl, David L; Farraye, Francis A; Kethu, Sripathi R; Kwon, Richard S; Mamula, Petar; Pedrosa, Marcos C; Rodriguez, Sarah A; Wong Kee Song, Louis-Michel

    2010-10-01

    The ASGE Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, with a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the "related articles" feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but in many cases data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the committee as a whole, and approved by the Governing Board of the ASGE. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through February 2010 for articles related to automated endoscope reprocessors, using the words endoscope reprocessing, endoscope cleaning, automated endoscope reprocessors, and high-level disinfection. Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment. Copyright © 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  8. Bilateral endoscopic endonasal marsupialization of nasopalatine duct cyst

    Directory of Open Access Journals (Sweden)

    Yohei Honkura

    2015-02-01

    Full Text Available Nasopalatine duct cysts are the most common non-odontogenic cysts in the maxilla, and are conventionally treated through a sublabial or palatine approach. Recently, the endoscopic approach has been used, but experience is extremely limited. We treated a 29-year-old male with nasopalatine duct cyst by endoscopic marsupialization, but paresthesia of the incisor region occurred after surgery. This paresthesia gradually remitted within 6 months. The nasopalatine nerve, which innervates the upper incisor region, enters two lateral canals separately at the nasal floor and exits the central main canal at the palate. Damage to the bilateral nasopalatine nerves might lead to paresthesia, so we recommend careful examination for nerve fibers during endoscopic surgery, especially if fenestration is performed on both sides.

  9. Indigo carmine for the selective endoscopic intervertebral nuclectomy.

    Science.gov (United States)

    Kim, Inn-Se; Kim, Kyung-Hoon; Shin, Sang-Wook; Kim, Tae-Kyun; Kim, Jeung-Il

    2005-08-01

    This study was undertaken to prove that the selectively infiltrated parts of nucleus pulposus with indigo carmine was degenerated parts of nucleus pulposus. This study was done, between August and October 2002, in 5 patients, who received endoscopic discectomy, due to intervertebral disc herniation. Discogram was done with mixture of indigo carmine and radioactive dye. Blue discolored part was removed through endoscope, and small undiscolored part was removed together for the control. The two parts were stained with hematoxylin and eosin and compared under the microscope. Undiscolored part was normal nucleus pulposus, composed of chondrocytes with a matrix of type II collagen and proteoglycan, mainly aggrecan. However, in discolored part, slits with destruction of collagen fiber array and ingrowth of vessel and nerve were observed. Using indigo carmine in endoscopic discectomy gives us selective removal of degenerated disc.

  10. Disposable sheath that facilitates endoscopic Raman spectroscopy

    Science.gov (United States)

    Wang, Wenbo; Short, Michael; Tai, Isabella T.; Zeng, Haishan

    2016-02-01

    In vivo endoscopic Raman spectroscopy of human tissue using a fiber optic probe has been previously demonstrated. However, there remain several technical challenges, such as a robust control over the laser radiation dose and measurement repeatability during endoscopy. A decrease in the signal to noise was also observed due to aging of Raman probe after repeated cycles of harsh reprocessing procedures. To address these issues, we designed and tested a disposable, biocompatible, and sterile sheath for use with a fiber optic endoscopic Raman probe. The sheath effectively controls contamination of Raman probes between procedures, greatly reduces turnaround time, and slows down the aging of the Raman probes. A small optical window fitted at the sheath cap maintained the measurement distance between Raman probe end and tissue surface. To ensure that the sheath caused a minimal amount of fluorescence and Raman interference, the optical properties of materials for the sheath, optical window, and bonding agent were studied. The easy-to-use sheath can be manufactured at a moderate cost. The sheath strictly enforced a maximum permissible exposure standard of the tissue by the laser and reduced the spectral variability by 1.5 to 8.5 times within the spectral measurement range.

  11. Aircraft electromagnetic compatibility

    Science.gov (United States)

    Clarke, Clifton A.; Larsen, William E.

    1987-06-01

    Illustrated are aircraft architecture, electromagnetic interference environments, electromagnetic compatibility protection techniques, program specifications, tasks, and verification and validation procedures. The environment of 400 Hz power, electrical transients, and radio frequency fields are portrayed and related to thresholds of avionics electronics. Five layers of protection for avionics are defined. Recognition is given to some present day electromagnetic compatibility weaknesses and issues which serve to reemphasize the importance of EMC verification of equipment and parts, and their ultimate EMC validation on the aircraft. Proven standards of grounding, bonding, shielding, wiring, and packaging are laid out to help provide a foundation for a comprehensive approach to successful future aircraft design and an understanding of cost effective EMC in an aircraft setting.

  12. Aircraft electromagnetic compatibility

    Science.gov (United States)

    Clarke, Clifton A.; Larsen, William E.

    1987-01-01

    Illustrated are aircraft architecture, electromagnetic interference environments, electromagnetic compatibility protection techniques, program specifications, tasks, and verification and validation procedures. The environment of 400 Hz power, electrical transients, and radio frequency fields are portrayed and related to thresholds of avionics electronics. Five layers of protection for avionics are defined. Recognition is given to some present day electromagnetic compatibility weaknesses and issues which serve to reemphasize the importance of EMC verification of equipment and parts, and their ultimate EMC validation on the aircraft. Proven standards of grounding, bonding, shielding, wiring, and packaging are laid out to help provide a foundation for a comprehensive approach to successful future aircraft design and an understanding of cost effective EMC in an aircraft setting.

  13. MINOP: development of a miniaturized endoscopic operation system for neurosurgery

    Science.gov (United States)

    Guber, Andreas E.; Wieneke, Paul

    1996-04-01

    Within the framework of R&D activities in the field of microsystems technology, the Institute for Microstructure Technology of Karlsruhe Research Center among others has started to improve the functionality of existing medicotechnical instruments by increased integration of microtechnical components. On the basis of microsystems fabrication techniques, completely novel medical endoscope systems have become feasible. In cooperation with clinical, technical and industrial partners, a novel endoscopic operation system based on microsystems technology is being developed by the Institute for Microstructure Technology and the Aesculap AG company, Tuttlingen within the framework of the MINOP joint project. This new system shall be applied above all in the field of neurosurgery. This newly conceived endosystem is characterized by a multitude of novelties. It can perform a number of both sensor and actor functions. Due to its extremely small outer diameter, it can be applied through minute openings. As a result of the integrated microfluidic control system, the flexible endoscope can be moved to the actual site of operation on a previously specified path. This will allow future bi- and triportal neuro-endoscopic interventions for critical operations in the brain area. The different lumina of the flexible endoscope fulfill various functions. Via the optical fibers, laser radiation may be led to the distal end of the endoscope. Using microtechnical fabrication methods, special plastic microlenses have been produced. The working channel can be applied for rinsing and removal. Furthermore, the cleaning of the optics or the taking of tissue samples are possible. If required, another laser fiber can be driven forward through the working channel for selective therapy. For the first time, high-performance microinstruments have been developed on the basis of novel materials. These instruments can be applied either through the working channel or through an additional trocar.

  14. Transaxillary Endoscopic Breast Augmentation

    Directory of Open Access Journals (Sweden)

    Hyung-Bo Sim

    2014-09-01

    Full Text Available The axillary technique is the most popular approach to breast augmentation among Korean women. Transaxillary breast augmentation is now conducted with sharp electrocautery dissection under direct endoscopic vision throughout the entire process. The aims of this method are clear: both a bloodless pocket and a sharp non-traumatic dissection. Round textured or anatomical cohesive gel implants have been used to make predictable well-defined inframammary creases because textured surface implants demonstrated a better stability attributable to tissue adherence compared with smooth surface implants. The axillary endoscopic technique has greatly evolved, and now the surgical results are comparable to those with the inframammary approach. The author feels that this technique is an excellent choice for young patients with an indistinct or absent inframammary fold, who do not want a scar in the aesthetic unit of their chest.

  15. Instrumentation: endoscopes and equipment.

    Science.gov (United States)

    Gaab, Michael R

    2013-02-01

    The technology and instrumentation for neuroendoscopy are described: endoscopes (principles, designs, applications), light sources, instruments, accessories, holders, and navigation. Procedures for cleaning, sterilizing, and storing are included. The description is based on the author's own technical development and neuroendoscopic experience, published technology and devices, and publications on endoscopic surgery. The main work horses in neuroendoscopy are rigid glass rod endoscopes (Hopkins optics) due to the optical quality, which allows full high-definition video imaging, different angles of view, and autoclavability, which is especially important in neuroendoscopy due to the risk of Creutzfeldt-Jakob disease infection. Applications are endoscopy assistance to microsurgery, stand-alone endoscopy controlled approaches such as transnasal skull base, ventriculoscopy, and cystoscopy in the cranium. Rigid glass rod optics are also applicable in spinal endoscopy and peripheral nerve decompression using special tubes and cannulas. Rigid minifiberoptics with less resolution may be used in less complex procedures (ventriculoscopy, cystoscopy, endoscopy assistance with pen-designs) and have the advantages of smaller diameters and disposable designs. Flexible fiberoptics are usually used in combination with rigid scopes and can be steered, e.g. through the ventricles, in spinal procedures for indications including syringomyelia and multicystic hydrocephalus. Upcoming flexible chip endoscopes ("chip-in-the-tip") may replace flexible fiberoptics in the future, offering higher resolution and cold LED-illumination, and may provide for stereoscopic neuroendoscopy. Various instruments (mechanical, coagulation, laser guides, ultrasonic aspirators) and holders are available. Certified methods for cleaning and sterilization, with special requirements in neuroapplications, are important. Neuroendoscopic instrumentation is now an established technique in neurosurgical practice and

  16. Endoscopic tissue diagnosis of cholangiocarcinoma.

    LENUS (Irish Health Repository)

    Harewood, Gavin C

    2008-09-01

    The extremely poor outcome in patients with cholangiocarcinoma, in large part, reflects the late presentation of these tumors and the challenging nature of establishing a tissue diagnosis. Establishing a diagnosis of cholangiocarcinoma requires obtaining evidence of malignancy from sampling of the epithelium of the biliary tract, which has proven to be challenging. Although endoscopic ultrasound-guided fine needle aspiration performs slightly better than endoscopic retrograde cholangiopancreatography in diagnosing cholangiocarcinoma, both endoscopic approaches demonstrate disappointing performance characteristics.

  17. DUPIC fuel compatibility assessment

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hang Bok; Rho, G. H.; Park, J. W. [and others

    2000-03-01

    The purpose of this study is to assess the compatibility of DUPIC(Direct Use of Spent PWR Fuel in CANDU Reactors) fuel with the current CANDU 6 reactor, which is one of the technology being developed to utilize the spent PWR fuel in CANDU reactors. The phase 1 study of this project includes the feasibility analysis on applicability of the current core design method, the feasibility analysis on operation of the DUPIC fuel core, the compatibility analysis on individual reactor system, the sensitivity analysis on the fuel composition, and the economic analysis on DUPIC fuel cycle. The results of the validation calculations have confirmed that the current core analysis system is acceptable for the feasibility study of the DUPIC fuel compatibility analysis. The results of core simulations have shown that both natural uranium and DUPIC fuel cores are almost the same from the viewpoint of the operational performance. For individual reactor system including reactively devices, the functional requirements of each system are satisfied in general. However, because of the pronounced power flattening in the DUPIC core, the radiation damage on the critical components increases, which should be investigated more in the future. The DUPIC fuel composition heterogeneity dose not to impose any serious effect on the reactor operation if the fuel composition is adjusted. The economics analysis has been performed through conceptual design studies on the DUPIC fuel fabrication, fuel handling in a plant, and spent fuel disposal, which has shown that the DUPIC fuel cycle is comparable to the once-trough fuel cycle considering uncertainties associated with unit costs of the fuel cycle components. The results of Phase 1 study have shown that it is feasible to use the DUPIC fuel in CANDU reactors without major changes in hardware. However further studies are required to confirm the safety of the reactor under accident condition.

  18. Elastomer Compatible With Oxygen

    Science.gov (United States)

    Martin, Jon W.

    1987-01-01

    Artificial rubber resists ignition on impact and seals at low temperatures. Filled fluoroelastomer called "Katiflex" developed for use in seals of vessels holding cold liquid and gaseous oxygen. New material more compatible with liquid oxygen than polytetrafluoroethylene. Provides dynamic seal at -196 degrees C with only 4 times seal stress required at room temperature. In contrast, conventional rubber seals burn or explode on impact in high-pressure oxygen, and turn hard or even brittle at liquid-oxygen temperatures, do not seal reliably, also see (MFS-28124).

  19. Nano-structured optical fiber bundles for remote SPR detection: a first step toward in vivo biomolecular analysis

    Science.gov (United States)

    Vindas, Karim; Engel, Elodie; Garrigue, Patrick; Livache, Thierry; Arbault, Stéphane; Sojic, Neso; Leroy, Loic

    2017-04-01

    This work presents the proof of concept of the detection of global and surface optical index variations by surface plasmon resonance (SPR) thanks to optical fiber bundles. This work is the first necessary step for the future design of a lab-on-fiber tool dedicated to molecular analysis for endoscopic diagnosis. Our approach is based on nanostructured optical fiber bundles comprising several thousands of individual optical fibers. These nanostructures were coated by a thin gold layer in order to gain interesting optical properties such like SPR. The sensitivity and resolution of the bundle to global optical index changes were measured in retro-reflection. We performed numerical simulations in order to optimize the fiber tip geometry, gold coating thickness and finally enhance their analytical performances. We achieved a resolution of 10-4 refractive index unit, which is fully compatible with the detection of biological interactions involving large proteins or bacteria. Finally, we proved that our sensor was sensitive to surface optical index variations and able to detect the adsorption of a thin self-assembled molecular layer.

  20. Endoscopic surveillance strategy after endoscopic resection for early gastric cancer.

    Science.gov (United States)

    Nishida, Tsutomu; Tsujii, Masahiko; Kato, Motohiko; Hayashi, Yoshito; Akasaka, Tomofumi; Iijima, Hideki; Takehara, Tetsuo

    2014-05-15

    Early detection of early gastric cancer (EGC) is important to improve the prognosis of patients with gastric cancer. Recent advances in endoscopic modalities and treatment devices, such as image-enhanced endoscopy and high-frequency generators, may make endoscopic treatment, such as endoscopic submucosal dissection, a therapeutic option for gastric intraepithelial neoplasia. Consequently, short-term outcomes of endoscopic resection (ER) for EGC have improved. Therefore, surveillance with endoscopy after ER for EGC is becoming more important, but how to perform endoscopic surveillance after ER has not been established, even though the follow-up strategy for more advanced gastric cancer has been outlined. Therefore, a surveillance strategy for patients with EGC after ER is needed.

  1. Rinsability of Orthophthalaldehyde from Endoscopes

    Directory of Open Access Journals (Sweden)

    Norman Miner

    2012-01-01

    Full Text Available Orthophthalaldehyde high level disinfectants are contraindicated for use with urological instruments such as cystoscopes due to anaphylaxis-like allergic reactions during surveillance of bladder cancer patients. Allergic reactions and mucosal injuries have also been reported following colonoscopy, laryngoscopy, and transesophageal echocardiography with devices disinfected using orthophthalaldehyde. Possibly these endoscopes were not adequately rinsed after disinfection by orthophthalaldehyde. We examined this possibility by means of a zone-of-inhibition test, and also a test to extract residues of orthophthalaldehyde with acetonitrile, from sections of endoscope insertion tube materials, to measure the presence of alkaline glutaraldehyde, or glutaraldehyde plus 20% w/w isopropanol, or ortho-phthalaldehyde that remained on the endoscope materials after exposure to these disinfectants followed by a series of rinses in water, or by aeration overnight. Zones of any size indicated the disinfectant had not been rinsed away from the endoscope material. There were no zones of inhibition surrounding endoscope materials soaked in glutaraldehyde or glutaraldehyde plus isopropanol after three serial water rinses according to manufacturers' rinsing directions. The endoscope material soaked in orthophthalaldehyde produced zones of inhibition even after fifteen serial rinses with water. Orthophthalaldehyde was extracted from the rinsed endoscope material by acetonitrile. These data, and other information, indicate that the high level disinfectant orthophthalaldehyde, also known as 1,2-benzene dialdehyde, cannot be rinsed away from flexible endoscope material with any practical number of rinses with water, or by drying overnight.

  2. Endoscopic capacity in West Africa.

    African Journals Online (AJOL)

    Abstract: Background: Levels of endoscopic demand and capacity in West Africa are unclear. Objectives: This paper aims to: 1. describe the current labor and endoscopic capacity, 2. quantify the impact of a mixed-meth- ods endoscopy course on healthcare professionals in West Africa, and 3. quantify the types of diagnoses ...

  3. Robot-assisted endoscopic surgery

    NARCIS (Netherlands)

    Ruurda, J.P.

    2003-01-01

    During the last three years, robot-assisted surgery systems are increasingly being applied in endoscopic surgery. They were introduced with the objective to overcome the challenges of standard endoscopic surgery. With the improvements in manipulation and visualisation that robotic-assistance offers,

  4. Endoscopic capacity in West Africa.

    African Journals Online (AJOL)

    edge among participants after didactics, objective data paired with subjective responses was more useful than either alone. Of 23 patients who received endoscopy, 7 required endoscopic intervention with 6 having gastric or esophageal varices. Currently the endoscopic capacity in West Africa is not sufficient. A formal GI ...

  5. Compatibility Assessment Tool

    Science.gov (United States)

    Egbert, James Allen

    2016-01-01

    In support of ground system development for the Space Launch System (SLS), engineers are tasked with building immense engineering models of extreme complexity. The various systems require rigorous analysis of pneumatics, hydraulic, cryogenic, and hypergolic systems. There are certain standards that each of these systems must meet, in the form of pressure vessel system (PVS) certification reports. These reports can be hundreds of pages long, and require many hours to compile. Traditionally, each component is analyzed individually, often utilizing hand calculations in the design process. The objective of this opportunity is to perform these analyses in an integrated fashion with the parametric CADCAE environment. This allows for systems to be analyzed on an assembly level in a semi-automated fashion, which greatly improves accuracy and efficiency. To accomplish this, component specific parameters were stored in the Windchill database to individual Creo Parametric models based on spec control drawings. These parameters were then accessed by using the Prime Analysis within Creo Parametric. MathCAD Prime spreadsheets were created that automatically extracted these parameters, performed calculations, and generated reports. The reports described component compatibility based on local conditions such as pressure, temperature, density, and flow rates. The reports also determined component pairing compatibility, such as properly sizing relief valves with regulators. The reports stored the input conditions that were used to determine compatibility to increase traceability of component selection. The desired workflow for using this tool would begin with a Creo Schematics diagram of a PVS system. This schematic would store local conditions and locations of components. The schematic would then populate an assembly within Creo Parametric, using Windchill database parts. These parts would have their attributes already assigned, and the MathCAD spreadsheets could begin running

  6. [Endoscopic vacuum-assisted closure].

    Science.gov (United States)

    Wedemeyer, J; Lankisch, T

    2013-03-01

    Anastomotic leakage in the upper and lower intestinal tract is associated with high morbidity and mortality. Within the last 10 years endoscopic treatment options have been accepted as sufficient treatment option of these surgical complications. Endoscopic vacuum assisted closure (E-VAC) is a new innovative endoscopic therapeutic option in this field. E-VAC transfers the positive effects of vacuum assisted closure (VAC) on infected cutaneous wounds to infected cavities that can only be reached endoscopically. A sponge connected to a drainage tube is endoscopically placed in the leakage and a continuous vacuum is applied. Sponge and vacuum allow removal of infected fluids and promote granulation of the leakage. This results in clean wound grounds and finally allows wound closure. Meanwhile the method was also successfully used in the treatment of necrotic pancreatitis.

  7. Soliton transmission and supercontinuum generation in holey fiber using a diode pumped ytterbium fiber source

    OpenAIRE

    Price, Jonathan H.V.; Belardi, W.; Monro, T.M.; Malinowski, A.; Piper, A.; Richardson, D.J.

    2002-01-01

    We report linear dispersion compensation, soliton pulse formation, soliton compression, and ultra-broad supercontinuum generation in a holey fiber with anomalous dispersion at wavelengths above 800nm. The holey fiber was seeded with ultrashort pulses from a diode pumped, Ytterbium (Yb)-doped fiber source operating at 1.06µm. The results highlight the compatibility of the rapidly developing holey fiber technology with short pulse Yb-doped fiber lasers for wide application.

  8. High-quality endoscope reprocessing decreases endoscope contamination.

    Science.gov (United States)

    Decristoforo, Petra; Kaltseis, Josef; Fritz, Andreas; Edlinger, Michael; Posch, Wilfried; Wilflingseder, Doris; Lass-Flörl, Cornelia; Orth-Höller, Dorothea

    2018-02-02

    Several outbreaks of severe infections due to contamination of gastrointestinal (GI) endoscopes, mainly duodenoscopes have been described previously. The rate of microbial endoscope contamination is varying dramatically in literature. Thus, the aim of this multicentre prospective study was to evaluate the hygiene quality of endoscopes and automated endoscope reprocessors (AERs) in Tyrol/Austria. In 2015 and 2016, a total of 463 GI endoscopes and 105 AERs from 29 endoscopy centres were analysed by a routine (R) and a combined routine and advanced (CRA) sampling procedure and investigated for microbial contamination by culture- and molecular-based analyses. The contamination rate of GI endoscopes was 1.3-4.6% according to national guideline, suggesting that 1.3-4.6 patients out of 100 could have had contacts with hygiene relevant microorganisms through an endoscopic intervention. Comparison of R and CRA sampling showed 1.8% of R versus 4.6% of CRA failing the acceptance criteria in phase I and 1.3% of R versus 3.0% of CRA samples in phase II. The most commonly identified indicator organism was Pseudomonas spp., mainly P. oleovorans. None of the tested viruses were detected in 40 samples. While AERs in phase I failed (n=9, 17.6%) mainly due to technical faults, phase II revealed lapses (n=6, 11.5%) only on account to microbial contamination of the last rinsing water, mainly with Pseudomonas spp. In the present study the contamination rate of endoscopes was low compared to results from other European countries, possibly due to high quality of endoscope reprocessing, drying and storage. Copyright © 2018 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  9. Polymer Optical Fibre Sensors for Endoscopic Opto-Acoustic Imaging

    DEFF Research Database (Denmark)

    Broadway, Christian; Gallego, Daniel; Woyessa, Getinet

    2015-01-01

    Opto-acoustic imaging (OAI) shows particular promise for in-vivo biomedical diagnostics. Its applications include cardiovascular, gastrointestinal and urogenital systems imaging. Opto-acoustic endoscopy (OAE) allows the imaging of body parts through cavities permitting entry. The critical parameter...... is the physical size of the device, allowing compatibility with current technology, while governing flexibility of the distal end of the endoscope based on the needs of the sensor. Polymer optical fibre (POF) presents a novel approach for endoscopic applications and has been positively discussed and compared...... in existing publications. A great advantage can be obtained for endoscopy due to a small size and array potential to provide discrete imaging speed improvements. Optical fibre exhibits numerous advantages over conventional piezo-electric transducers, such as immunity from electromagnetic interference...

  10. Endoscopic egomotion computation

    Science.gov (United States)

    Bergen, Tobias; Ruthotto, Steffen; Rupp, Stephan; Winter, Christian; Münzenmayer, Christian

    2010-03-01

    Computer assistance in Minimally Invasive Surgery is a very active field of research. Many systems designed for Computer Assisted Surgery require information about the instruments' positions and orientations. Our main focus lies on tracking a laparoscopic ultrasound probe to generate 3D ultrasound volumes. State-of-the-art tracking methods such as optical or electromagnetic tracking systems measure pose with respect to a fixed extra-body coordinate system. This causes inaccuracies of the reconstructed ultrasound volume in the case of patient motion, e.g. due to respiration. We propose attaching an endoscopic camera to the ultrasound probe and calculating the camera motion from the video sequence with respect to the organ surface. We adapt algorithms developed for solving the relative pose problem to recreate the camera path during the ultrasound sweep over the organ. By this image-based motion estimation camera motion can only be determined up to an unknown scale factor, known as the depth-speed-ambiguity. We show, how this problem can be overcome in the given scenario, exploiting the fact, that the distance of the camera to the organ surface is fixed and known. Preprocessing steps are applied to compensate for endoscopic image quality deficiencies.

  11. Non-endoscopic Mechanical Endonasal Dacryocystorhinostomy

    Directory of Open Access Journals (Sweden)

    Mohammad Etezad Razavi

    2011-01-01

    Full Text Available To circumvent the disadvantages of endoscopic dacryocystorhinostomy such as small rhinostomy size, high failure rate and expensive equipment, we hereby introduce a modified technique of non-endoscopic mechanical endonasal dacryocystorhinostomy (NE-MEDCR. Surgery is performed under general anesthesia with local decongestion of the nasal mucosa. A 20-gauge vitrectomy light probe is introduced through the upper canaliculus until it touches the bony medial wall of the lacrimal sac. While directly viewing the transilluminated target area, a nasal speculum with a fiber optic light carrier is inserted. An incision is made vertically or in a curvilinear fashion on the nasal mucosa in the lacrimal sac down to the bone using a Freer periosteum elevator. Approximately 1 to 1.5 cm of nasal mucosa is removed with Blakesley forceps. Using a lacrimal punch, the thick bone of the frontal process of the maxilla is removed and the inferior half of the sac is uncovered. The lacrimal sac is tented into the surgical site with the light probe and its medial wall is incised using a 3.2 mm keratome and then excised using the Blakesley forceps. The procedure is completed by silicone intubation. The NE-MEDCR technique does not require expensive instrumentation and is feasible in any standard ophthalmic surgical setting.

  12. Fertilization compatibility of spawning corals

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set includes experimental results of fertilization assays to characterize genetic compatibility between individual parental genotypes. Targeted species...

  13. Agave Americana Leaf Fibers

    Directory of Open Access Journals (Sweden)

    Ashish Hulle

    2015-02-01

    Full Text Available The growing environmental problems, the problem of waste disposal and the depletion of non-renewable resources have stimulated the use of green materials compatible with the environment to reduce environmental impacts. Therefore, there is a need to design products by using natural resources. Natural fibers seem to be a good alternative since they are abundantly available and there are a number of possibilities to use all the components of a fiber-yielding crop; one such fiber-yielding plant is Agave Americana. The leaves of this plant yield fibers and all the parts of this plant can be utilized in many applications. The “zero-waste” utilization of the plant would enable its production and processing to be translated into a viable and sustainable industry. Agave Americana fibers are characterized by low density, high tenacity and high moisture absorbency in comparison with other leaf fibers. These fibers are long and biodegradable. Therefore, we can look this fiber as a sustainable resource for manufacturing and technical applications. Detailed discussion is carried out on extraction, characterization and applications of Agave Americana fiber in this paper.

  14. Optical transfection using an endoscope-like system

    Science.gov (United States)

    Ma, Nan; Gunn-Moore, Frank; Dholakia, Kishan

    2011-02-01

    Optical transfection is a powerful method for targeted delivery of therapeutic agents to biological cells. A tightly focused pulsed laser beam may transiently change the permeability of a cell membrane to facilitate the delivery of foreign genetic material into cells. We report the first realization of an endoscope-like integrated system for optical transfection. An imaging fiber (coherent optical fiber bundle) with ~6000 cores (pixels) embedded in a fiber cladding of ~300 μm in diameter, produces an image circle (area) of ~270 μm diam. This imaging fiber, with an ordered axicon lens array chemically etched at its exit face, is used for the delivery of a femtosecond laser to the cell membrane for optical transfection along with subcellular resolution imaging. A microcapillary-based microfluidic system for localized drug delivery was also combined in this miniature, flexible system. Using this novel system, a plasmid transfection efficiency up to ~72% was obtained for CHO-K1 cells. This endoscope-like system opens a range of exciting applications, in particular, in the targeted in vivo optical microsurgery area.

  15. Endoscopic third ventriculostomy

    Directory of Open Access Journals (Sweden)

    Yad Ram Yadav

    2012-01-01

    Full Text Available Endoscopic third ventriculostomy (ETV is considered as a treatment of choice for obstructive hydrocephalus. It is indicated in hydrocephalus secondary to congenital aqueductal stenosis, posterior third ventricle tumor, cerebellar infarct, Dandy-Walker malformation, vein of Galen aneurism, syringomyelia with or without Chiari malformation type I, intraventricular hematoma, post infective, normal pressure hydrocephalus, myelomeningocele, multiloculated hydrocephalus, encephalocele, posterior fossa tumor and craniosynostosis. It is also indicated in block shunt or slit ventricle syndrome. Proper Pre-operative imaging for detailed assessment of the posterior communicating arteries distance from mid line, presence or absence of Liliequist membrane or other membranes, located in the prepontine cistern is useful. Measurement of lumbar elastance and resistance can predict patency of cranial subarachnoid space and complex hydrocephalus, which decides an ultimate outcome. Water jet dissection is an effective technique of ETV in thick floor. Ultrasonic contact probe can be useful in selected patients. Intra-operative ventriculo-stomography could help in confirming the adequacy of endoscopic procedure, thereby facilitating the need for shunt. Intraoperative observations of the patent aqueduct and prepontine cistern scarring are predictors of the risk of ETV failure. Such patients may be considered for shunt surgery. Magnetic resonance ventriculography and cine phase contrast magnetic resonance imaging are effective in assessing subarachnoid space and stoma patency after ETV. Proper case selection, post-operative care including monitoring of ICP and need for external ventricular drain, repeated lumbar puncture and CSF drainage, Ommaya reservoir in selected patients could help to increase success rate and reduce complications. Most of the complications develop in an early post-operative, but fatal complications can develop late which indicate an importance of

  16. Endoscopic laser scalpel for head and neck cancer surgery

    Science.gov (United States)

    Patel, Snehal; Rajadhyaksha, Milind; Kirov, Stefan; Li, Yongbiao; Toledo-Crow, Ricardo

    2012-02-01

    Minimally invasive surgical (MIS) techniques, such as laparoscopic surgery and endoscopy, provide reliable disease control with reduced impact on the function of the diseased organ. Surgical lasers can ablate, cut and excise tissue while sealing small blood vessels minimizing bleeding and risk of lymphatic metastases from tumors. Lasers with wavelengths in the IR are readily absorbed by water causing minimal thermal damage to adjacent tissue, ideal for surgery near critical anatomical structures. MIS techniques have largely been unable to adopt the use of lasers partly due to the difficulty in bringing the laser into the endoscopic cavity. Hollow waveguide fibers have been adapted to bring surgical lasers to endoscopy. However, they deliver a beam that diverges rapidly and requires careful manipulation of the fiber tip relative to the target. Thus, the principal obstacle for surgical lasers in MIS procedures has been a lack of effective control instruments to manipulate the laser in the body cavity and accurately deliver it to the targeted tissue. To overcome this limitation, we have designed and built an endoscopic laser system that incorporates a miniature dual wedge beam steering device, a video camera, and the control system for remote and /or robotic operation. The dual wedge Risley device offers the smallest profile possible for endoscopic use. Clinical specifications and design considerations will be presented together with descriptions of the device and the development of its control system.

  17. Streaming video-based 3D reconstruction method compatible with existing monoscopic and stereoscopic endoscopy systems

    Science.gov (United States)

    Bouma, Henri; van der Mark, Wannes; Eendebak, Pieter T.; Landsmeer, Sander H.; van Eekeren, Adam W. M.; ter Haar, Frank B.; Wieringa, F. Pieter; van Basten, Jean-Paul

    2012-06-01

    Compared to open surgery, minimal invasive surgery offers reduced trauma and faster recovery. However, lack of direct view limits space perception. Stereo-endoscopy improves depth perception, but is still restricted to the direct endoscopic field-of-view. We describe a novel technology that reconstructs 3D-panoramas from endoscopic video streams providing a much wider cumulative overview. The method is compatible with any endoscope. We demonstrate that it is possible to generate photorealistic 3D-environments from mono- and stereoscopic endoscopy. The resulting 3D-reconstructions can be directly applied in simulators and e-learning. Extended to real-time processing, the method looks promising for telesurgery or other remote vision-guided tasks.

  18. Endoscopic ultrasound and pancreas divisum

    DEFF Research Database (Denmark)

    Rana, Surinder S; Gonen, Can; Vilmann, Peter

    2012-01-01

    cholangiopancreatography is the gold standard for its diagnosis, but is invasive and associated with significant adverse effects. Endoscopic ultrasound (EUS) allows the detailed evaluation of the pancreaticobiliary ductal system without injecting contrast in these ducts. Moreover, it provides detailed images...

  19. Supercontinuum as a light source for miniaturized endoscopes.

    Science.gov (United States)

    Lu, M K; Lin, H Y; Hsieh, C C; Kao, F J

    2016-09-01

    In this work, we have successfully implemented supercontinuum based illumination through single fiber coupling. The integration of a single fiber illumination with a miniature CMOS sensor forms a very slim and powerful camera module for endoscopic imaging. A set of tests and in vivo animal experiments are conducted accordingly to characterize the corresponding illuminance, spectral profile, intensity distribution, and image quality. The key illumination parameters of the supercontinuum, including color rendering index (CRI: 72%~97%) and correlated color temperature (CCT: 3,100K~5,200K), are modified with external filters and compared with those from a LED light source (CRI~76% & CCT~6,500K). The very high spatial coherence of the supercontinuum allows high luminosity conduction through a single multimode fiber (core size~400μm), whose distal end tip is attached with a diffussion tip to broaden the solid angle of illumination (from less than 10° to more than 80°).

  20. Compatible quantum theory.

    Science.gov (United States)

    Friedberg, R; Hohenberg, P C

    2014-09-01

    Formulations of quantum mechanics (QM) can be characterized as realistic, operationalist, or a combination of the two. In this paper a realistic theory is defined as describing a closed system entirely by means of entities and concepts pertaining to the system. An operationalist theory, on the other hand, requires in addition entities external to the system. A realistic formulation comprises an ontology, the set of (mathematical) entities that describe the system, and assertions, the set of correct statements (predictions) the theory makes about the objects in the ontology. Classical mechanics is the prime example of a realistic physical theory. A straightforward generalization of classical mechanics to QM is hampered by the inconsistency of quantum properties with classical logic, a circumstance that was noted many years ago by Birkhoff and von Neumann. The present realistic formulation of the histories approach originally introduced by Griffiths, which we call 'compatible quantum theory (CQT)', consists of a 'microscopic' part (MIQM), which applies to a closed quantum system of any size, and a 'macroscopic' part (MAQM), which requires the participation of a large (ideally, an infinite) system. The first (MIQM) can be fully formulated based solely on the assumption of a Hilbert space ontology and the noncontextuality of probability values, relying in an essential way on Gleason's theorem and on an application to dynamics due in large part to Nistico. Thus, the present formulation, in contrast to earlier ones, derives the Born probability formulas and the consistency (decoherence) conditions for frameworks. The microscopic theory does not, however, possess a unique corpus of assertions, but rather a multiplicity of contextual truths ('c-truths'), each one associated with a different framework. This circumstance leads us to consider the microscopic theory to be physically indeterminate and therefore incomplete, though logically coherent. The completion of the theory

  1. Endoscopic decompression for intraforaminal and extraforaminal nerve root compression

    Directory of Open Access Journals (Sweden)

    Tarukado Kiyoshi

    2011-03-01

    Full Text Available Abstract Objective The purpose of this study was to evaluate the outcome of endoscopic decompression surgery for intraforaminal and extraforaminal nerve root compression in the lumbar spine. Methods The records from seventeen consecutive patients treated with endoscopic posterior decompression without fusion for intaforaminal and extraforaminal nerve root compression in the lumbar spine (7 males and 10 females, mean age: 67.9 ± 10.7 years were retrospectively reviewed. The surgical procedures consisted of lateral or translaminal decompression with or without discectomy. The following items were investigated: 1 the preoperative clinical findings; 2 the radiologic findings including MRI and computed tomography-discography; and 3 the surgical outcome as evaluated using the Japanese Orthopaedic Association scale for lower back pain (JOA score. Results All patients had neurological findings compatible with a radiculopathy, such as muscle weakness and sensory disturbance. MRI demonstrated the obliteration of the normal increased signal intensity fat in the intervertebral foramen. Ten patients out of 14 who underwent computed tomography-discography exhibited disc protrusion or herniation. Selective nerve root block was effective in all patients. During surgery, 12 patients were found to have a protruded disc or herniation that compressed the nerve root. Sixteen patients reported pain relief immediately after surgery. Conclusions Intraforaminal and extraforaminal nerve root compression is a rare but distinct pathological condition causing severe radiculopathy. Endoscopic decompression surgery is considered to be an appropriate and less invasive surgical option.

  2. Novel Optical Fiber Materials With Engineered Brillouin Gain Coefficients SSL 1: Novel Fiber Lasers

    Science.gov (United States)

    2015-12-29

    Hawkins, C. Ryan, A. D. Yablon, R. Stolen, J. Ballato. Single- and few-moded lithium aluminosilicate optical fiber for athermal Brillouin strain...invited presentations 5 invited journal papers 1 journal cover 1 paper awarded "Spotlight on Optics" by the Optical Society of America 1 paper...Derived Fiber 25 G. Strontium Aluminosilicate Fiber 28 H. Lithium Aluminosilicate Fiber 30 V. Investigations Into Other Compatible

  3. Novel developments in endoscopic mucosal imaging

    NARCIS (Netherlands)

    van der Sommen, F; Curvers, W L; Nagengast, W B

    2018-01-01

    Endoscopic techniques such as High-definition and optical-chromoendoscopy have had enormous impact on endoscopy practice. Since these techniques allow assessment of most subtle morphological mucosal abnormalities, further improvements in endoscopic practice lay in increasing the detection efficacy

  4. Endoscopic Transaxillary Near Total Thyroidectomy

    Science.gov (United States)

    Ejeh, Ijeoma Acholonu; Speights, Fredne; Rashid, Qammar N.; Ideis, Mustafa

    2006-01-01

    Background: Since first reported in 1996, endoscopic minimally invasive surgery of the cervical region has been shown to be safe and effective in the treatment of benign thyroid and parathyroid disease. The endoscopic transaxillary technique uses a remote lateral approach to the thyroid gland. Because of the perceived difficulty in accessing the contralateral anatomy of the thyroid gland, this technique has typically been reserved for patients with unilateral disease. Objectives: The present study examines the safety and feasibility of the transaxillary technique in dissecting and assessment of both thyroid lobes in performing near total thyroidectomy. Methods: Prior to this study we successfully performed endoscopic transaxillary thyroid lobectomy in 32 patients between August 2003 and August 2005. Technical feasibility in performing total thyroidectomy using this approach was accomplished first utilizing a porcine model followed by three human cadaver models prior to proceeding to human surgery. After IRB approval three female patients with histories of enlarging multinodular goiter were selected to undergo endoscopic near total thyroidectomy. Results: The average operative time for all models was 142 minutes (range 57–327 min). The three patients in this study had clinically enlarging multinodular goiters with an average size of 4 cm. The contralateral recurrent laryngeal nerve and parathyroid glands were identified in all cases. There was no post-operative bleeding, hoarseness or subcutaneous emphysema. Conclusion: Endoscopic transaxillary near total thyroidectomy is feasible and can be performed safely in human patients with bilateral thyroid disease. PMID:16882421

  5. Fiber webs

    Science.gov (United States)

    Roger M. Rowell; James S. Han; Von L. Byrd

    2005-01-01

    Wood fibers can be used to produce a wide variety of low-density three-dimensional webs, mats, and fiber-molded products. Short wood fibers blended with long fibers can be formed into flexible fiber mats, which can be made by physical entanglement, nonwoven needling, or thermoplastic fiber melt matrix technologies. The most common types of flexible mats are carded, air...

  6. Endoscopic Treatment for Early Gastric Cancer

    OpenAIRE

    Kim, Sang Gyun

    2011-01-01

    Endoscopic resection has been accepted as a curative modality for early gastric cancer (EGC). Since conventional endoscopic mucosal resection (EMR) has been introduced, many improvements in endoscopic accessories and techniques have been achieved. Recently, endoscopic submucosal dissection (ESD) using various electrosurgical knives has been performed for complete resection of EGC and enables complete resection of EGC, which is difficult to completely resect in the era of conventional EMR. Cur...

  7. Total extraperitoneal endoscopic hernioplasty (TEP).

    Science.gov (United States)

    Kuthe, A; Mainik, F; Flade-Kuthe, R

    2014-04-01

    One can no longer think about modern hernia surgery without mentioning endoscopic techniques. But due to their high technical demands the learning curve is comparatively long. And by technical mistakes and their consequences (pain, recurrence, complications) the benefits of the endoscopic techniques can easily be turned to drawbacks. The following text explains the steps of the total extraperitoneal endoscopic hernioplasty (TEP) technique in detail pointing out alternatives and risks. From preparation, indication and positioning, from trocar placement to extraperitoneal dissection and mesh placement, the principles of TEP are elucidated in respect of local anatomy and possible complications. The text as well as the accompanying video in the Mediathek are based on the authors' 20 years of experience in the TEP technique. Both of them may help in safe TEP application to minimise the complication rate as well as recurrences. Then patients can benefit from the advantages of this technique. Georg Thieme Verlag KG Stuttgart · New York.

  8. Endoscopic treatment of lumbar arachnoiditis.

    Science.gov (United States)

    Warnke, J P; Mourgela, S

    2007-02-01

    The diagnosis of lumbar arachnoiditis remains complex and often inconclusive. Using the technique of lumbar subarachnoidal endoscopy (thecaloscopy), the pathology can be identified and the patient treated with long-term effects on the symptoms. Endoscopic operations were performed on 23 patients suffering from varying symptoms with an enlarged lumbar subarachnoidal space. Having confirmed the diagnosis of lumbar arachnoiditis, a number of endoscopic operations ranging from adhesiolysis to subarachno-epidurostomy were carried out. Radicular symptoms in lumbar arachnoiditis were successfully relieved by various endoscopic dissection techniques, such as restoration of the improved CSF flow by subarachno-epidurostomy along the rootlet. This has been identified as one of the causal factors of the clinical symptoms. In cases where lumbar pain persists in spite of a previous thecaloscopy, further treatment with a lumboperitoneal shunt device has proved most successful.

  9. Endoscopic Palliation for Pancreatic Cancer

    Directory of Open Access Journals (Sweden)

    Mihir Bakhru

    2011-04-01

    Full Text Available Pancreatic cancer is devastating due to its poor prognosis. Patients require a multidisciplinary approach to guide available options, mostly palliative because of advanced disease at presentation. Palliation including relief of biliary obstruction, gastric outlet obstruction, and cancer-related pain has become the focus in patients whose cancer is determined to be unresectable. Endoscopic stenting for biliary obstruction is an option for drainage to avoid the complications including jaundice, pruritus, infection, liver dysfunction and eventually failure. Enteral stents can relieve gastric obstruction and allow patients to resume oral intake. Pain is difficult to treat in cancer patients and endoscopic procedures such as pancreatic stenting and celiac plexus neurolysis can provide relief. The objective of endoscopic palliation is to primarily address symptoms as well improve quality of life.

  10. Colorectal endoscopic mucosal resection (EMR).

    Science.gov (United States)

    Kandel, Pujan; Wallace, Michael B

    2017-08-01

    Colonoscopy has the benefit of detecting and treating precancerous adenomatous polyps and thus reduces mortality associated with CRC. Screening colonoscopy is the keystone for prevention of colorectal cancer. Over the last 20 years there has been increased in the management of large colorectal polyps from surgery to endoscopic removal techniques which is less invasive. Traditionally surgical resection was the treatment of choice for many years for larger polyps but colectomy poses significant morbidity of 14-46% and mortality of up to 7%. There are several advantages of endoscopic resection technique over surgery; it is less invasive, less expensive, has rapid recovery, and preserves the normal gut functions. In addition patient satisfaction and efficacy of EMR is higher with minor complications. Thus, this has facilitated the development of advanced resection technique for the treatment of large colorectal polyps called as endoscopic mucosal resection (EMR). Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Motion magnification for endoscopic surgery

    Science.gov (United States)

    McLeod, A. Jonathan; Baxter, John S. H.; de Ribaupierre, Sandrine; Peters, Terry M.

    2014-03-01

    Endoscopic and laparoscopic surgeries are used for many minimally invasive procedures but limit the visual and haptic feedback available to the surgeon. This can make vessel sparing procedures particularly challenging to perform. Previous approaches have focused on hardware intensive intraoperative imaging or augmented reality systems that are difficult to integrate into the operating room. This paper presents a simple approach in which motion is visually enhanced in the endoscopic video to reveal pulsating arteries. This is accomplished by amplifying subtle, periodic changes in intensity coinciding with the patient's pulse. This method is then applied to two procedures to illustrate its potential. The first, endoscopic third ventriculostomy, is a neurosurgical procedure where the floor of the third ventricle must be fenestrated without injury to the basilar artery. The second, nerve-sparing robotic prostatectomy, involves removing the prostate while limiting damage to the neurovascular bundles. In both procedures, motion magnification can enhance subtle pulsation in these structures to aid in identifying and avoiding them.

  12. High power compatible internally sensed optical phased array.

    Science.gov (United States)

    Roberts, Lyle E; Ward, Robert L; Francis, Samuel P; Sibley, Paul G; Fleddermann, Roland; Sutton, Andrew J; Smith, Craig; McClelland, David E; Shaddock, Daniel A

    2016-06-13

    The technical embodiment of the Huygens-Fresnel principle, an optical phased array (OPA) is an arrangement of optical emitters with relative phases controlled to create a desired beam profile after propagation. One important application of an OPA is coherent beam combining (CBC), which can be used to create beams of higher power than is possible with a single laser source, especially for narrow linewidth sources. Here we present an all-fiber architecture that stabilizes the relative output phase by inferring the relative path length differences between lasers using the small fraction of light that is back-reflected into the fiber at the OPA's glass-air interface, without the need for any external sampling optics. This architecture is compatible with high power continuous wave laser sources (e.g., fiber amplifiers) up to 100 W per channel. The high-power compatible internally sensed OPA was implemented experimentally using commercial 15 W fiber amplifiers, demonstrating an output RMS phase stability of λ/194, and the ability to steer the beam at up to 10 kHz.

  13. Endoscopic brow lifts uber alles.

    Science.gov (United States)

    Patel, Bhupendra C K

    2006-12-01

    Innumerable approaches to the ptotic brow and forehead have been described in the past. Over the last twenty-five years, we have used all these techniques in cosmetic and reconstructive patients. We have used the endoscopic brow lift technique since 1995. While no one technique is applicable to all patients, the endoscopic brow lift, with appropriate modifications for individual patients, can be used effectively for most patients with brow ptosis. We present the nuances of this technique and show several different fixation methods we have found useful.

  14. Comparison of laser-assisted damage in soft tissue using bi-directional and forward-firing optical fiber

    Science.gov (United States)

    Kim, Changhwan; Sohn, Ik-Bu; Park, Hoyong; Lee, Yong Joong; Lee, Ho

    2014-03-01

    Laser-assisted endoscopic surgery is made possible by employing optical devices such as fiber optics and hollow wave-guides. In some applications of laser-assisted endoscopic surgery, it is necessary to change the direction of the light emission. Our group reported a new fabrication method for bi-directional firing fibers. The conical surface of the fiber tip made the bi-directional emission of the laser light at the distal end of the fiber. In this study, we employed the bi-directional firing fiber for laser-assisted coagulation of soft tissue. The developed fiber and the normal forward-firing fiber are used for the endoscopic delivery system of a continuous IR laser into an in vitro porcine liver. The ablation and coagulation pattern were compared for two distinctive fiber systems. Regardless of the laser's parameters, the bi-directional firing fiber produced a cavity and coagulation zone with more or less a circular shape, while the forward fiber produced an elongated cavity and coagulation region. The bi-directional firing fiber produced wider and shorter coagulation and cavity zones compared to that of the forward-firing fiber. We expect the bi-directional firing fiber to be an excellent optical delivery system for endoscopic laser-hyperthermia when used against various tumors in the liver, breast and thyroid.

  15. Cross-polarization endoscopic optical coherence tomography in urology

    Science.gov (United States)

    Zagaynova, E. V.; Gladkova, N. D.; Gelikonov, V. M.; Streltsova, O. S.; Ledayev, D. S.; Atduev, V. A.; Balandina, E. V.; Snopova, L. B.

    2009-02-01

    We present results obtained using a two-channel portable device for CP OCT based on the polarization-maintaining fiber. The device is capable of acquiring OCT images of the object in direct and orthogonal polarizations simultaneously. The OCT system has an endoscopic forward-looking probe (2.7 mm in diameter). The CP OCT imaging was done in 64 postoperative specimens, for 30 patients during cystoscopy with suspicion of urothelial neoplasia, and for 11 patients with prostatectomy due to cancer. After surgery in the tissue specimen we immediately introduced surgical suture and investigated a bladder wall by CP OCT. When comparing OCT images and histology slides we can distinguish tissue layers based on position of the suture material. CP OCT images were compared with histological data. Special staining - Sirius Red for collagen types was applied. OCT -visualization of sympathetic nerve was made during open surgery. We found, that a strong signal in orthogonal polarization is produced by structures consisting of Type I collagen. We demonstrated that endoscopic benign and early malignant pathological processes that cannot be detected by standard OCT may be differentiated by CP OCT. Sympathetic nerve of neurovascular bundle gives a strong signal in both polarizations: direct and orthogonal. Based on these CP OCT features we can visualize nerve during operation (open or endoscopic surgery) and thus preserve it.

  16. Conifer fibers as reinforcing materials for polypropylene-based composites

    DEFF Research Database (Denmark)

    Plackett, David; Chengzhi, Chuai; Almdal, Kristoffer

    2001-01-01

    Conifer fibers were used to reinforce polypropylene (PP). To improve the compatibility between the conifer fibers and the PP matrix, the fibers were either grafted with maleated PP (MAPP), treated by adding MAPP, or mixed with ethylene/propylene/diene terpolymer (EPDM). The treatments resulted in...

  17. Five wavelength DFB fiber lase source

    DEFF Research Database (Denmark)

    Varming, Poul; Hübner, Jörg; Kristensen, M.

    1997-01-01

    Stable single-mode laser sources with narrow linewidth are key components in high-capacity wavelength-division multiplexed (WDM) optical communication systems. Distributed feedback (DFB) and distributed Bragg reflection (DBR) fiber lasers are compact devices, which are able to provide stable sing......-mode operation. They are inherently fiber compatible and cascadable. We present a multiwavelength laser source consisting of five fiber DFB lasers spliced together and pumped by a single 60-mW 1480-nm semiconductor laser...

  18. Endoscopic third ventriculostomy and choroid

    African Journals Online (AJOL)

    Sitwala

    Finally, gratitude goes to my supervisors Prof. Dele, Prof. Ngoma and Dr. Nkandu for guidance and Dr. Ben. Andrews for helping with the editing of the document. REFERENCES. 1. Warf BC. Hydrocephalus in Uganda: the predominance of infectious origin and primary management with endoscopic third ventriculostomy.

  19. Complications of endoscopic variceal therapy

    African Journals Online (AJOL)

    annaline

    endoscopic treatment of oesophageal and gastric varices, and consequently the incidence varies widely in reported .... and pleuritic chest pain, fever, an exudative pleural effusion and worsening encephalopathy.21,82 .... contrast, Ogle et al. found no instance of acid reflux into the oesophagus but patients who received ...

  20. Colonic perforation following endoscopic retrograde ...

    African Journals Online (AJOL)

    Case report. A 41-year-old woman with HIV infection who had not had anti- retroviral drugs presented with jaundice secondary to choledo- cholithiasis. Multiple common bile duct stones were extracted at endoscopic retrograde cholangiopancreatography (ERCP). She failed to keep appointments for laparoscopic ...

  1. Endoscopic treatment of orbital tumors.

    Science.gov (United States)

    Signorelli, Francesco; Anile, Carmelo; Rigante, Mario; Paludetti, Gaetano; Pompucci, Angelo; Mangiola, Annunziato

    2015-03-16

    Different orbital and transcranial approaches are performed in order to manage orbital tumors, depending on the location and size of the lesion within the orbit. These approaches provide a satisfactory view of the superior and lateral aspects of the orbit and the optic canal but involve risks associated with their invasiveness because they require significant displacement of orbital structures. In addition, external approaches to intraconal lesions may also require deinsertion of extraocular muscles, with subsequent impact on extraocular mobility. Recently, minimally invasive techniques have been proposed as valid alternative to external approaches for selected orbital lesions. Among them, transnasal endoscopic approaches, "pure" or combined with external approaches, have been reported, especially for intraconal lesions located inferiorly and medially to the optic nerve. The avoidance of muscle detachment and the shortness of the surgical intraorbital trajectory makes endoscopic approach less invasive, thus minimizing tissue damage. Endoscopic surgery decreases the recovery time and improves the cosmetic outcome not requiring skin incisions. The purpose of this study is to review and discuss the current surgical techniques for orbital tumors removal, focusing on endoscopic approaches to the orbit and outlining the key anatomic principles to follow for safe tumor resection.

  2. Colonic perforation following endoscopic retrograde ...

    African Journals Online (AJOL)

    We highlight a potentially lethal complication of acute severe pancreatitis that may not be suspected in severely ill patients. A 41-year-old woman developed acute severe pancreatitis following endoscopic retrograde cholangiopancreatography (ERCP) for suspected choledocholithiasis. When her condition deteriorated ...

  3. ENDOSCOPIC TRANSURETHRAL RESECTION OF BILHARZIAL

    African Journals Online (AJOL)

    1 1 10-5 704. African Journal of Urology. V0/. 9, NO. 1, 2003. 36-40. ENDOSCOPIC TRANSURETHRAL RESECTION OF BILHARZIAL. ULCERS OF THE URINARY BLADDER. SINGLE-CENTER ... ulcers (78% de novo and 22% recurrent ul- cers after previous open partial .... tion cf its tip is used for resection. However, it.

  4. ENDOSCOPIC TRANSURETHRAL RESECTION OF BILHARZIAL

    African Journals Online (AJOL)

    1 1 10-5 704. African Journal of Urology. Vol. 9, NO. 1, 2003. 36-40. ENDOSCOPIC TRANSURETHRAL RESECTION OF BILHARZIAL. ULCERS OF THE URINARY BLADDER. SINGLE-CENTER ... ulcers (78% de novo and 22% recurrent ul- cers after previous open partial .... tion of its tip is used for resection. HoWever, it.

  5. ENDOSCOPIC MACROPLASTIQUETM INJECTION FOR THE ...

    African Journals Online (AJOL)

    Objectives To evaluate the role, safety and efficacy of endoscopic MacroplastiqueTM implants in the management of female stress incontinence. Material and Methods Between 1995 and 1999, transurethral submucosal injection of MacroplastiqueTM was performed in 68 women (mean age 58 years, range 32 — 85 years) ...

  6. Design and performance of optical endoscopes for the early detection of cancer

    Science.gov (United States)

    Keenan, Maureen Molly

    Cancer is a multistage, heterogeneous disease that develops through a series of genetic mutations. Early stage cancer is most responsive to treatment but can be the hardest to detect due to its small size, lack of definitive symptoms and potential location deep in the body. Whole body imaging methods, MRI/CT/PET, lack the necessary resolution to detect cellular level abnormalities. Optical methods, which have sufficient resolution, can be miniaturized into endoscopes, which are necessary to overcome limited penetration of light into tissue. By combining optical coherence tomography (OCT) and fluorescence imaging methods it is possible to create endoscopes sensitive to molecular and structural changes. I applied a dual-modality 2mm diameter rigid endoscope to the study of the natural history of colon cancer in a mouse model, and later applied this knowledge to the design and characterization of a 0.8 mm dual-modality flexible probe for use in human fallopian tubes. By using this endoscope, which is introduced through the natural orifice and is compatible with existing hysteroscopes, high-risk women could be screened in a procedure at a similar level of invasiveness as a colonoscopy. Therefore, the endoscope fills this gap in clinical care for women at high-risk for ovarian cancer.

  7. Natural fibers

    Science.gov (United States)

    Craig M. Clemons; Daniel F. Caulfield

    2005-01-01

    The term “natural fibers” covers a broad range of vegetable, animal, and mineral fibers. However, in the composites industry, it usually refers to wood fiber and agrobased bast, leaf, seed, and stem fibers. These fibers often contribute greatly to the structural performance of the plant and, when used in plastic composites, can provide significant reinforcement. Below...

  8. Atuarfitsialak: Greenland's Cultural Compatible Reform

    Science.gov (United States)

    Wyatt, Tasha R.

    2012-01-01

    In 2002, Greenlandic reform leaders launched a comprehensive, nation-wide reform to create culturally compatible education. Greenland's reform work spans the entire educational system and includes preschool through higher education. To assist their efforts, reform leaders adopted the Standards for Effective Pedagogy developed at the Center for…

  9. Compatibility of Ohio trail users

    Science.gov (United States)

    Roger E. McCay; George H. Moeller

    1976-01-01

    Compatibility indexes show how Ohio trail users feel about meeting each other on the trail. All four of the major types of trail users-hikers, horseback riders, bicycle riders, and motorcycle riders-enjoy meeting their own kind. But they also feel antagonism toward the faster, more mechanized trail users; e.g., everyone likes hikers, but few like motorcycle riders....

  10. Design optimization for car compatibility

    NARCIS (Netherlands)

    Nastic, T.; Schoofs, A.J.G.; Mooi, H.G.

    1999-01-01

    Nowadays traffic safety and occupant protection get a lot of attention due to the large number of fatalities and injuries in car accidents. The occupant protection in two-vehicle crashes can be improved by car-to-car compatibility, which means well balanced crashworthiness characteristics of both

  11. Electromagnetic compatibility in power electronics

    CERN Document Server

    Costa , François; Revol , Bertrand

    2014-01-01

    Scientists largely attribute the recent deterioration of the electromagnetic environment to power electronics. This realization has spurred the study of methodical approaches to electromagnetic compatibility designs as explored in this text. The book addresses major challenges, such as handling numerous parameters vital to predicting electro magnetic effects and achieving compliance with line-harmonics norms, while proposing potential solutions.

  12. Alternative Treatment of Osteoma Using an Endoscopic Holmium-YAG Laser

    Directory of Open Access Journals (Sweden)

    Ba Leun Han

    2012-07-01

    Full Text Available Osteoma is one of the most common tumors of the cranial vault and the facial skeleton. For osteoma in the facial region, endoscopic resection is widely used to prevent surgical scarring. Tumors in a total of 14 patients were resected using an endoscopic holmium-doped yttrium aluminium garnet (Ho:YAG laser with a long flexible fiber. Aside from having the advantage of not leaving a scar due to the use of endoscopy, this procedure allowed resection at any position, was minimally invasive, and caused less postoperative pain. This method yielded excellent cosmetic results, so the endoscopic Ho:YAG laser is expected to emerge as a good treatment option for osteoma.

  13. Endoscopic prevention of post-endoscopic retrograde cholangiopancreatography pancreatitis.

    Science.gov (United States)

    Lee, Tae Hoon; Park, Do Hyun

    2014-11-28

    Post-endoscopic retrograde cholangiopancreatography (ERCP) pancreatitis (PEP) is not an uncommon adverse event but may be an avoidable complication. Although pancreatitis of severe grade is reported in 0.1%-0.5% of ERCP patients, a serious clinical course may be lethal. For prevention of severe PEP, patient risk stratification, appropriate selection of patients using noninvasive diagnostic imaging methods such as magnetic resonance cholangiopancreatography or endoscopic ultrasonography (EUS), and avoidance of unnecessary invasive procedures, are important measures to be taken before any procedure. Pharmacological prevention is also commonly attempted but is usually ineffective. No ideal agent has not yet been found and the available data conflict. Currently, rectal non-steroidal anti-inflammatory drugs are used to prevent PEP in high-risk patients, but additional studies using larger numbers of subjects are necessary to confirm any prophylactic effect. In this review, we focus on endoscopic procedures seeking to prevent or decrease the severity of PEP. Among various cannulation methods, wire-guided cannulation, precut fistulotomy, and transpancreatic septostomy are reviewed. Prophylactic pancreatic stent placement, which is the best-known prophylactic method, is reviewed with reference to the ideal stent type, adequate duration of stent placement, and stent-related complications. Finally, we comment on other treatment alternatives, and make the point that further advances in EUS-guided techniques may afford useful PEP prophylaxis.

  14. A novel imaging system of optical detection on cancers and tissues in gastrointestinal endoscope using high-color-rendering white and color tunable LEDs

    Science.gov (United States)

    Nishikawa, Jun; Taguchi, Tsunemasa; Uchida, Yuji; Kurai, Satoshi; Yanai, Hideo; Kiyotoki, Shu; Okamoto, Takeshi; Higaki, Shingo; Sakaida, Isao

    2010-02-01

    The use of white or color tunable LEDs (light-emitting diodes), which can replace a large light source apparatus and light-guiding fiber bundle, enable the miniaturization of the whole endoscope system and remove constraints on the design of its shape. We have developed a novel white LED for a new experimental prototype LED-illuminated gastrointestinal endoscope having the color rendering in the clinically important red range at around 600 nm.­

  15. Monte Carlo analysis on probe performance for endoscopic diffuse optical spectroscopy of tubular organ

    Science.gov (United States)

    Zhang, Yunyao; Zhu, Jingping; Cui, Weiwen; Nie, Wei; Li, Jie; Xu, Zhenghong

    2015-03-01

    We investigated the performance of endoscopic diffuse optical spectroscopy probes with circular or linear fiber arrangements for tubular organ cancer detection. Probe performance was measured by penetration depth. A Monte Carlo model was employed to simulate light transport in the hollow cylinder that both emits and receives light from the inner boundary of the sample. The influence of fiber configurations and tissue optical properties on penetration depth was simulated. The results show that under the same condition, probes with circular fiber arrangement penetrate deeper than probes with linear fiber arrangement, and the difference between the two probes' penetration depth decreases with an increase in the 'distance between source and detector (SD)' and the radius of the probe. Other results show that the penetration depths and their differences both decrease with an increase in the absorption coefficient and the reduced scattering coefficient but remain constant with changes in the anisotropy factor. Moreover, the penetration depth was more affected by the absorption coefficient than the reduced scattering coefficient. It turns out that in NIR band, probes with linear fiber arrangements are more appropriate for diagnosing superficial cancers, whereas probes with circular fiber arrangements should be chosen for diagnosing adenocarcinoma. But in UV-VIS band, the two probe configurations exhibit nearly the same. These results are useful in guiding endoscopic diffuse optical spectroscopy-based diagnosis for esophageal, cervical, colorectal and other cancers.

  16. Endoscopic subsurface imaging in tissues

    Energy Technology Data Exchange (ETDEWEB)

    Demos, S G; Staggs, M; Radousky, H B

    2001-02-12

    The objective of this work is to develop endoscopic subsurface optical imaging technology that will be able to image different tissue components located underneath the surface of the tissue at an imaging depth of up to 1 centimeter. This effort is based on the utilization of existing technology and components developed for medical endoscopes with the incorporation of the appropriate modifications to implement the spectral and polarization difference imaging technique. This subsurface imaging technique employs polarization and spectral light discrimination in combination with image processing to remove a large portion of the image information from the outer layers of the tissue which leads to enhancement of the contrast and image quality of subsurface tissue structures.

  17. Endoscopic approach to subepithelial lesions.

    Science.gov (United States)

    Menon, Laila; Buscaglia, Jonathan M

    2014-05-01

    Endoscopy and endoscopic ultrasound (EUS) play a critical role in the detection and management of subepithelial lesions of the gastrointestinal tract. The most common subepithelial lesions detected by endoscopists are gastrointestinal stromal tumors (GISTs), leiomyomas, lipomas, granular cell tumors (GCTs), pancreatic rests and carcinoid tumors. These lesions can be classified based on unique histochemical staining and the gastrointestinal layer of origin. While the majority of the lesions are considered benign, some tumors such as GISTs and carcinoids have a strong propensity for malignant transformation. Therefore, appropriate endoscopic versus surgical management based on size and location is crucial in the prevention of malignant transformation and metastasis. In this review, we provide a systematic approach to the diagnosis, management and treatment of commonly encountered subepithelial lesions.

  18. Endoscopic ultrasound and pancreas divisum

    DEFF Research Database (Denmark)

    Rana, Surinder S; Gonen, Can; Vilmann, Peter

    2012-01-01

    Pancreas divisum is the most common congenital anatomic variation of the pancreatic ductal anatomy and in most of the individuals it is asymptomatic. However, in minority of individuals it is presumed to cause recurrent acute pancreatitis and chronic pancreatitis. Endoscopic retrograde cholangiop......Pancreas divisum is the most common congenital anatomic variation of the pancreatic ductal anatomy and in most of the individuals it is asymptomatic. However, in minority of individuals it is presumed to cause recurrent acute pancreatitis and chronic pancreatitis. Endoscopic retrograde...... of the parenchyma also. Therefore EUS, both radial and linear, has potential for being a minimally invasive diagnostic modality for pancreas divisum. A number of EUS criteria have been suggested for the diagnosis of pancreas divisum. These criteria have varying sensitivity and specificity and hence there is a need...

  19. Multiparty Compatibility for Concurrent Objects

    Directory of Open Access Journals (Sweden)

    Roly Perera

    2016-06-01

    Full Text Available Objects and actors are communicating state machines, offering and consuming different services at different points in their lifecycle. Two complementary challenges arise when programming such systems. When objects interact, their state machines must be "compatible", so that services are requested only when they are available. Dually, when objects refine other objects, their state machines must be "compliant", so that services are honoured whenever they are promised. In this paper we show how the idea of multiparty compatibility from the session types literature can be applied to both of these problems. We present an untyped language in which concurrent objects are checked automatically for compatibility and compliance. For simple objects, checking can be exhaustive and has the feel of a type system. More complex objects can be partially validated via test cases, leading to a methodology closer to continuous testing. Our proof-of-concept implementation is limited in some important respects, but demonstrates the potential value of the approach and the relationship to existing software development practices.

  20. Endoscopic cubital tunnel recurrence rates.

    Science.gov (United States)

    Cobb, Tyson K; Sterbank, Patrick T; Lemke, Jon H

    2010-06-01

    Cubital tunnel syndrome is the second most common nerve entrapment in the upper extremity. There are no current publications concerning the recurrence rates after endoscopic cubital tunnel release. The purpose of this study is to evaluate the recurrence rate of endoscopic cubital tunnel release compared to published reports of recurrence following open cubital tunnel procedures. We reviewed 134 consecutive cases of endoscopic cubital tunnel release in 117 patients. There were 104 cases in 94 patients with greater than 3 months follow-up. The mean follow-up time was 736 days. They were grouped using Dellon's classification. Two literature control groups were used from published reports of recurrence rate following open cubital tunnel release. A recurrence was identified if the patient was symptom-free following surgery but had symptoms reappear 3 months or more after surgery as defined in the literature. Of the 104 cases, 92.31% had more than a 4-month follow-up. One case (0.96%) met the criteria for recurrence at 4 months postprocedure. Data were then compared to the literature control groups used from published reports of recurrence rates following open cubital tunnel release. Pooled, the combined controls had 22 of 180 cases (12.22%) with recurrences. The percentage of procedure recurrence varied significantly with p value equal to 0.0004. It is recognized that there is a lack of common classification and comparative analysis of these studies, but they do classify preoperative grading and recurrence similarly. We are 95% confident that our true recurrence rate is between 0.02% and 5.24% and that endoscopic cubital tunnel release has a recurrence rate, which is not higher than open cubital tunnel release literature controls.

  1. Endoscopic versus microscopic stapes surgery.

    Science.gov (United States)

    Surmelioglu, Ozgur; Ozdemir, Suleyman; Tarkan, Ozgur; Tuncer, Ulku; Dagkiran, Muhammed; Cetik, Fikret

    2017-06-01

    The aim of this study to compare the outcomes and complications of endoscopic stapes surgery versus microscopic stapes surgery. This study involved patients who underwent stapedotomy at the Department of Otorhinolaryngology, Faculty of Medicine, Cukurova University between January 2012 and July 2014. The patients were divided into two groups. Patients in group I were operated with endoscope and patients in group II were operated with microscope. Pure tone audiometry was carried out in all patients preoperatively. Peroperative surgical findings, complications, and duration of surgery were noted and compared between the two groups. Air conduction and bone conduction thresholds were measured at frequencies of 500, 1000, 2000, and 4000Hz, and the mean (±SD) air-bone gap was noted. Mean preoperative air-bone gap was 36.9±6.8dB (23.3-50dB) in group I and 35.1±6dB (26.6-50dB) in group II. Mean postoperative air-bone gap was 9.3±7.1dB (0-30dB) in group I and 13.5±9.7dB (1.6-35dB) in group II. The difference in preoperative and postoperative air-bone gap between the two groups was statistically significant (p=0.023). Patients in group I did not complain of postoperative pain but this was felt in four patients in group II. The difference was statistically significant (p=0.045). Endoscopic stapes surgery has many benefits such as good visualization, and easy accessibility to the stapes, oval window niche, and facial nerve. Removal of the scutum and manipulation of the chorda tympani nerve are less frequent with the endoscopic technique. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. Carbon fiber resin matrix interphase: effect of carbon fiber surface treatment on composite performance

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, S.; Megerdigian, C.; Papalia, R.

    1985-04-01

    Carbon fibers are supplied by various manufacturers with a predetermined level of surface treatment and matrix compatible sizings. Surface treatment of the carbon fiber increases the active oxygen content, the polarity and the total free surface energy of the fiber surface. This study is directed toward determining the effect of varying carbon fiber surface treatment on the composite performance of thermoset matrix resins. The effect of varying fiber surface treatment on performance of a promising proprietary sizing is also presented. 6 references, 11 figures.

  3. All-fiber hybrid photon-plasmon circuits: integrating nanowire plasmonics with fiber optics.

    Science.gov (United States)

    Li, Xiyuan; Li, Wei; Guo, Xin; Lou, Jingyi; Tong, Limin

    2013-07-01

    We demonstrate all-fiber hybrid photon-plasmon circuits by integrating Ag nanowires with optical fibers. Relying on near-field coupling, we realize a photon-to-plasmon conversion efficiency up to 92% in a fiber-based nanowire plasmonic probe. Around optical communication band, we assemble an all-fiber resonator and a Mach-Zehnder interferometer (MZI) with Q-factor of 6 × 10(6) and extinction ratio up to 30 dB, respectively. Using the MZI, we demonstrate fiber-compatible plasmonic sensing with high sensitivity and low optical power.

  4. Endoscopic Aspects of Gastric Syphilis

    Directory of Open Access Journals (Sweden)

    Mariana Souza Varella Frazão

    2012-01-01

    Full Text Available Introduction. Considered as a rare event, gastric syphilis (GS is reported as an organic form of involvement. Low incidence of GS emphasizes the importance of histopathological analysis. Objective. We aim to characterize GS endoscopic aspects in an immunocompetent patient. Case Report. A 23-year-old man presented with epigastric pain associated with nausea, anorexia, generalized malaise and 11 kg weight loss that started 1 month prior to his clinical consultation. Physical examination was normal except for mild abdominal tenderness in epigastrium. Endoscopy observed diminished gastric expandability and diffuse mucosal lesions, from cardia to pylorus. Gastric mucosa was thickened, friable, with nodular aspect, and associated with ulcers lesions. Gastric biopsies were performed, and histopathological analysis resulted in dense inflammatory infiltration rich in plasmocytes. Syphilis serologies were positive for VDRL and Treponema pallidum reagents. Immunohistochemical tests were positive for Treponema pallidum and CD138. The patient was treated with penicillin, leading to resolution of his clinical complaints and endoscopic findings. Conclusion. Diagnosis suspicion of GS is important in view of its nonspecific presentation. Patients with gastric symptoms that mimic neoplastic disease should be investigated thoroughly based on the fact that clinical, endoscopic, and histological findings can easily be mistaken for lymphoma or plastic linitis.

  5. Endoscopically removed giant submucosal lipoma

    Directory of Open Access Journals (Sweden)

    Jovanović Ivan

    2007-01-01

    Full Text Available Background. Although uncommon, giant submucosal colon lipomas merit attention as they are often presented with dramatic clinical features such as bleeding, acute bowel obstruction, perforation and sometimes may be mistaken for malignancy. There is a great debate in the literature as to how to treat them. Case report. A patient, 67-year old, was admitted to the Clinic due to a constipation over the last several months, increasing abdominal pain mainly localized in the left lower quadrant accompanied by nausea, vomiting and abdominal distension. Physical examination was unremarkable and the results of the detailed laboratory tests and carcinoembryonic antigen remained within normal limits. Colonoscopy revealed a large 10 cm long, and 4 to 5 cm in diameter, mobile lesion in his sigmoid colon. Conventional endoscopic ultrasound revealed 5 cm hyperechoic lesion of the colonic wall. Twenty MHz mini-probe examination showed that lesion was limited to the submucosa. Since polyp appeared too large for a single transaction, it was removed piecemeal. Once the largest portion of the polyp has been resected, it was relatively easy to place the opened snare loop around portions of the residual polyp. Endoscopic resection was carried out safely without complications. Histological examination revealed the common typical histological features of lipoma elsewhere. The patient remained stable and eventually discharged home. Four weeks later he suffered no recurrent symptoms. Conclusion. Colonic lipomas can be endoscopically removed safely eliminating unnecessary surgery.

  6. Non-equilibrium atmospheric pressure microplasma jet: An approach to endoscopic therapies

    Science.gov (United States)

    Zuo, Xiao; Wei, Yu; Wei Chen, Long; Dong Meng, Yue; Plasma Medicine Team

    2013-08-01

    Atmospheric pressure microplasma jet generated in a long hollow core optical fiber is studied to verify the potential feasibility of endoscopic therapies. Thermal damage and electric shock to the human body were suppressed by two technical methods, i.e., the high-voltage resistant flexible tube wrapped on the optical fiber and a power resistor of 100 kΩ connected between the power supply and the copper foil electrode. Optical emission spectra analysis indicated that many kinds of active radicals like excited atomic O and OH, were generated in the microplasma jet. In addition, the applications of the microplasma jet on sterilization and lung cancer cell apoptosis were presented. After 5 min of exposures to the microplasma jet, the cell viability and the bacillus subtilis replication decreased to about 3% and zero, respectively. More investigations are needed to improve the plasma-aided endoscopic therapies.

  7. Fiber biology

    Science.gov (United States)

    Cotton fiber cells arising from seed epidermis is the most important agricultural textile commodity in the world. To produce fully mature fibers, approximately two months of fiber developmental process are required. The timing of four distinctive fiber development stages consisting of initiation, ...

  8. Multimode-Optical-Fiber Imaging Probe

    Science.gov (United States)

    Jackson, Deborah

    2000-01-01

    Currently, endoscopic surgery uses single-mode fiber-bundles to obtain in vivo image information inside orifices of the body. This limits their use to the larger natural bodily orifices and to surgical procedures where there is plenty of room for manipulation. The knee joint, for example can be easily viewed with a fiber optic viewer, but joints in the finger cannot. However, there are a host of smaller orifices where fiber endoscopy would play an important role if a cost effective fiber probe were developed with small enough dimensions (endoscopy of the ventricles and spinal canal. To solve this problem, this work describes an approach for recovering images from. tightly confined spaces using multimode fibers and analytically demonstrates that the concept is sound. The proof of concept draws upon earlier works that concentrated on image recovery after two-way transmission through a multimode fiber as well as work that demonstrated the recovery of images after one-way transmission through a multimode fiber. Both relied on generating a phase conjugated wavefront which was predistorted with the characteristics of the fiber. The described approach also relies on generating a phase conjugated wavefront, but utilizes two fibers to capture the image at some intermediate point (accessible by the fibers, but which is otherwise visually unaccessible).

  9. Compatibility Determination : [Crescent Lake NWR 2003 hunting

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This Compatibility Determination states that hunting deer and upland birds at Crescent Lake National Wildlife Refuge is compatible with Refuge purposes.

  10. [Compatibility determinations Squaw Creek National Wildlife Refuge

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This document provides two compatibility determinations; one stated that the proposed agricultural practices (row crop farming) are compatible with Refuge objectives...

  11. Fiber Amplifiers

    DEFF Research Database (Denmark)

    Rottwitt, Karsten

    2017-01-01

    The chapter provides a discussion of optical fiber amplifiers and through three sections provides a detailed treatment of three types of optical fiber amplifiers, erbium doped fiber amplifiers (EDFA), Raman amplifiers, and parametric amplifiers. Each section comprises the fundamentals including...... the basic physics and relevant in-depth theoretical modeling, amplifiers characteristics and performance data as a function of specific operation parameters. Typical applications in fiber optic communication systems and the improvement achievable through the use of fiber amplifiers are illustrated....

  12. Community–groundwater compatibility assessments: An approach ...

    African Journals Online (AJOL)

    Data processing and analyses include the statistical processing of the collected data to assess the comprehensive measure of groundwater compatibility per area, and the individual indicators of the groundwater-compatibility index are given a relative score. This enables the different indicators for groundwater compatibility ...

  13. Electromagnetic compatibility principles and applications

    CERN Document Server

    Weston, David A

    2001-01-01

    This totally revised and expanded reference/text provides comprehensive, single-source coverage of the design, problem solving, and specifications of electromagnetic compatibility (EMC) into electrical equipment/systems-including new information on basic theories, applications, evaluations, prediction techniques, and practical diagnostic options for preventing EMI through cost-effective solutions. Offers the most recent guidelines, safety limits, and standards for human exposure to electromagnetic fields! Containing updated data on EMI diagnostic verification measurements, as well as over 900 drawings, photographs, tables, and equations-500 more than the previous edition

  14. Parallel Information Processing (Image Transmission Via Fiber Bundle and Multimode Fiber

    Science.gov (United States)

    Kukhtarev, Nicholai

    2003-01-01

    Growing demand for visual, user-friendly representation of information inspires search for the new methods of image transmission. Currently used in-series (sequential) methods of information processing are inherently slow and are designed mainly for transmission of one or two dimensional arrays of data. Conventional transmission of data by fibers requires many fibers with array of laser diodes and photodetectors. In practice, fiber bundles are also used for transmission of images. Image is formed on the fiber-optic bundle entrance surface and each fiber transmits the incident image to the exit surface. Since the fibers do not preserve phase, only 2D intensity distribution can be transmitted in this way. Each single mode fiber transmit only one pixel of an image. Multimode fibers may be also used, so that each mode represent different pixel element. Direct transmission of image through multimode fiber is hindered by the mode scrambling and phase randomization. To overcome these obstacles wavelength and time-division multiplexing have been used, with each pixel transmitted on a separate wavelength or time interval. Phase-conjugate techniques also was tested in, but only in the unpractical scheme when reconstructed image return back to the fiber input end. Another method of three-dimensional imaging over single mode fibers was demonstrated in, using laser light of reduced spatial coherence. Coherence encoding, needed for a transmission of images by this methods, was realized with grating interferometer or with the help of an acousto-optic deflector. We suggest simple practical holographic method of image transmission over single multimode fiber or over fiber bundle with coherent light using filtering by holographic optical elements. Originally this method was successfully tested for the single multimode fiber. In this research we have modified holographic method for transmission of laser illuminated images over commercially available fiber bundle (fiber endoscope, or

  15. Endoscopic versus external approach dacryocystorhinostomy: A ...

    African Journals Online (AJOL)

    The difference was not statistically significant (P = 0.609). Conclusion: Intranasal endoscopic DCR is a simple, minimally invasive, day care procedure and had comparable result with conventional external DCR. Keywords: Dacryocystorhinostomy, endoscopic, external. Nigerian Medical Journal | Vol. 54 | Issue 3 | May-June ...

  16. Transgastric endoscopic splenectomy: is it possible?

    Science.gov (United States)

    Kantsevoy, S V; Hu, B; Jagannath, S B; Vaughn, C A; Beitler, D M; Chung, S S C; Cotton, P B; Gostout, C J; Hawes, R H; Pasricha, P J; Magee, C A; Pipitone, L J; Talamini, M A; Kalloo, A N

    2006-03-01

    We have previously reported the feasibility of diagnostic and therapeutic peritoneoscopy including liver biopsy, gastrojejunostomy, and tubal ligation by an oral transgastric approach. We present results of per-oral transgastric splenectomy in a porcine model. The goal of this study was to determine the technical feasibility of per-oral transgastric splenectomy using a flexible endoscope. We performed acute experiments on 50-kg pigs. All animals were fed liquids for 3 days prior to procedure. The procedures were performed under general anesthesia with endotracheal intubation. The flexible endoscope was passed per orally into the stomach and puncture of the gastric wall was performed with a needle knife. The puncture was extended to create a 1.5-cm incision using a pull-type sphincterotome, and a double-channel endoscope was advanced into the peritoneal cavity. The peritoneal cavity was insufflated with air through the endoscope. The spleen was visualized. The splenic vessels were ligated with endoscopic loops and clips, and then mesentery was dissected using electrocautery. Endoscopic splenectomy was performed on six pigs. There were no complications during gastric incision and entrance into the peritoneal cavity. Visualization of the spleen and other intraperitoneal organs was very good. Ligation of the splenic vessels and mobilization of the spleen were achieved using commercially available devices and endoscopic accessories. Transgastric endoscopic splenectomy in a porcine model appears technically feasible. Additional long-term survival experiments are planned.

  17. Endoscopic cubital tunnel release: a systematic review.

    Science.gov (United States)

    Smeraglia, Francesco; Del Buono, Angelo; Maffulli, Nicola

    2015-01-01

    Theoretical advantages of endoscopic cubital tunnel release are the short incision, lower risk of nerve damage, reduced manipulation of the nerve and possible faster recovery. We systematically searched Medline (PubMed), Web of Science and Scopus databases using the following keywords: 'endoscopic ulnar nerve', 'endoscopic cubital nerve', 'endoscopic ulnar compression' and 'endoscopic ulnar neuropathy'. Twenty-one studies were included in this review. The quality of the studies was assessed using the Coleman Methodological Score. Endoscopic release is effective for cubital tunnel entrapment and allows adequate visualization of the site of entrapment. There is a negative association between the severity of the compression and reported outcomes. Injury to the medial branch of the antebrachial cutaneous nerve is less frequent thanks to the limited dissection. The most frequent complication is the development of a hematoma. It is unclear whether ulnar nerve instability is a contraindication to simple decompression. The shorter time to return to work and the cosmetic appearance of the scar can be considered advantages of the endoscopic technique. There is a need to perform randomized clinical trials with common and validated scoring system with a longer duration of follow-up. The literature pertinent to endoscopic cubital tunnel release is lacking in the evaluation of the learning curve. Further investigations are necessary to assess the role of ulnar nerve instability. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Endoscopic third ventriculostomy in idiopathic normal pressure ...

    African Journals Online (AJOL)

    Objective: To determine the efficacy of endoscopic fenestration of the third ventricle in the treatment of idiopathic normal pressure hydrocephalus. Methods: 16 patients with idiopathic normal pressure hydrocephalus were treated by endoscopic third ventriculostomy. This study lasted three years. All patients were over 50 ...

  19. ENDOSCOPIC TREATMENT OF CHYLURIA USING POVIDONE

    African Journals Online (AJOL)

    Objective:-To evaluate the safety and efficacy of povidone iodine with contrast agent as a sclerosant for the endoscopic treatment of chylurla. -. Patients and Methods: From December 1999 to October 2003, a total of 22 patients having chylurla were treated. After their baseline evaluation they were subjected to endoscopic ...

  20. Duodenal diverticular bleeding: an endoscopic challenge

    Directory of Open Access Journals (Sweden)

    Eduardo Valdivielso-Cortázar

    Full Text Available Duodenal diverticula are an uncommon cause of upper gastrointestinal bleeding. Until recently, it was primarily managed with surgery, but advances in the field of endoscopy have made management increasingly less invasive. We report a case of duodenal diverticular bleeding that was endoscopically managed, and review the literature about the various endoscopic therapies thus far described.

  1. Endoscopic third ventriculostomy in idiopathic normal pressure ...

    African Journals Online (AJOL)

    Mohammed Ahmed Eshra

    2013-12-22

    Dec 22, 2013 ... Abstract Objective: To determine the efficacy of endoscopic fenestration of the third ventricle in the treatment of idiopathic normal pressure hydrocephalus. Methods: 16 patients with idiopathic normal pressure hydrocephalus were treated by endoscopic third ventriculostomy. This study lasted three years.

  2. Studies on scintillating fiber response

    Energy Technology Data Exchange (ETDEWEB)

    Albers, D. [Bonn Univ. (Germany). Inst. fuer Strahlen- und Kernphysik; Bisplinghoff, J.; Bollmann, R.; Buesser, K.; Cloth, P.; Diehl, O.; Dohrmann, F.; Drueke, V.; Engelhardt, H.P.; Ernst, J.; Eversheim, P.D.; Filges, D.; Gasthuber, M.; Gebel, R.; Greiff, J.; Gross, A.; Gross-Hardt, R.; Heine, A.; Heider, S.; Hinterberger, F.; Igelbrink, M.; Jahn, R.; Jeske, M.; Langkau, R.; Lindlein, J.; Maier, R.; Maschuw, R.; Mayer-Kuckuk, T.; Mertler, G.; Metsch, B.; Mosel, F.; Mueller, M.; Muenstermann, M.; Paetz genannt Schieck, H.; Petry, H.R.; Prasuhn, D.; Rohdjess, H.; Rosendaal, D.; Ross, U.; Rossen, P. von; Scheid, H.; Schirm, N.; Schulz-Rojahn, M.; Schwandt, F.; Scobel, W.; Steeg, B.; Sterzenbach, G.; Trelle, H.J.; Wellinghausen, A.; Wiedmann, W.; Woller, K.; Ziegler, R. [Institut fuer Strahlen- und Kernphysik, Universitaet Bonn, Bonn (Germany)]|[1. Institut fuer Experimentalphysik, Universitaet Hamburg, Hamburg (Germany)]|[Institut fuer Kernphysik, KFA, Juelich (Germany)]|[Institut fuer Theor. Kernphysik, Universitaet Bonn, Bonn (Germany)]|[Institut fuer Kernphysik, Universitaet Koeln, Koeln (Germany)

    1995-03-11

    Scintillating fibers of type Bicron BCF-12 with 2 x 2 mm{sup 2} cross section, up to 600 mm length, and PMMA cladding have been tested, in conjunction with the multi-channel photomultiplier Hamamatsu R 4760, with minimum ionizing electrons. The impact of cladding, extramural absorbers and/or wrapping on the light attenuation and photoelectron yield is studied in detail. Fibers have been circularly bent with radii of 171 mm and arranged in two layers to bundles forming granulated scintillator rings. Their performance in the EDDA experiment at COSY for detection of high energy protons revealed typically more than 9 (6) photoelectrons per fiber from bundles with (without) mirror on the rear side, guaranteeing detection efficiencies >99% and full compatibility with corresponding solid scintillator rings. The time resolution of 3.4 ns FWHM per fiber read out is essentially due to the R 4760. (orig.).

  3. Studies on scintillating fiber response

    Science.gov (United States)

    Albers, D.; Bisplinghoff, J.; Bollmann, R.; Büßer, K.; Cloth, P.; Diehl, O.; Dohrmann, F.; Drüke, V.; Engelhardt, H. P.; Ernst, J.; Eversheim, P. D.; Filges, D.; Gasthuber, M.; Gebel, R.; Greiff, J.; Groß, A.; Groß-Hardt, R.; Heine, A.; Heider, S.; Hinterberger, F.; Igelbrink, M.; Jahn, R.; Jeske, M.; Langkau, R.; Lindlein, J.; Maier, R.; Maschuw, R.; Mayer-Kuckuk, T.; Mertler, G.; Metsch, B.; Mosel, F.; Müller, M.; Münstermann, M.; Paetz gen. Schieck, H.; Petry, H. R.; Prasuhn, D.; Rohdjeß, H.; Rosendaal, D.; Roß, U.; von Rossen, P.; Scheid, H.; Schirm, N.; Schulz-Rojahn, M.; Schwandt, F.; Scobel, W.; Steeg, B.; Sterzenbach, G.; Trelle, H. J.; Wellinghausen, A.; Wiedmann, W.; Woller, K.; Ziegler, R.

    1996-02-01

    Scintillating fibers of type Bicron BCF-12 with 2 × 2 mm 2 cross section, up to 600 mm length, and PMMA cladding have been tested, in conjunction with the multi-channel photomultiplier Hamamatsu R 4760, with minimum ionizing electrons. The impact of cladding, extramural absorbers and/or wrapping on the light attenuation and photoelectron yield is studied in detail. Fibers have been circularly bent with radii of 171 mm and arranged in two layers to bundles forming granulated scintillator rings. Their performance in the EDDA experiment at COSY for detection of high energy protons revealed typically more than 9 (6) photoelectrons per fiber from bundles with (without) mirror on the rear side, guaranteeing detection efficiencies >99% and full compatibility with corresponding solid scintillator rings. The time resolution of 3.4 ns FWHM per fiber read out is essentially due to the R 4760.

  4. Integrated biophotonics in endoscopic oncology

    Science.gov (United States)

    Muguruma, Naoki; DaCosta, Ralph S.; Wilson, Brian C.; Marcon, Norman E.

    2009-02-01

    Gastrointestinal endoscopy has made great progress during last decade. Diagnostic accuracy can be enhanced by better training, improved dye-contrast techniques method, and the development of new image processing technologies. However, diagnosis using conventional endoscopy with white-light optical imaging is essentially limited by being based on morphological changes and/or visual attribution: hue, saturation and intensity, interpretation of which depends on the endoscopist's eye and brain. In microlesions in the gastrointestinal tract, we still rely ultimately on the histopathological diagnosis from biopsy specimens. Autofluorescence imaging system has been applied for lesions which have been difficult to morphologically recognize or are indistinct with conventional endoscope, and this approach has potential application for the diagnosis of dysplastic lesions and early cancers in the gastrointestinal tract, supplementing the information from white light endoscopy. This system has an advantage that it needs no administration of a photosensitive agent, making it suitable as a screening method for the early detection of neoplastic tissues. Narrow band imaging (NBI) is a novel endoscopic technique which can distinguish neoplastic and non-neoplastic lesions without chromoendoscopy. Magnifying endoscopy in combination with NBI has an obvious advantage, namely analysis of the epithelial pit pattern and the vascular network. This new technique allows a detailed visualization in early neoplastic lesions of esophagus, stomach and colon. However, problems remain; how to combine these technologies in an optimum diagnostic strategy, how to apply them into the algorithm for therapeutic decision-making, and how to standardize several classifications surrounding them. 'Molecular imaging' is a concept representing the most novel imaging methods in medicine, although the definition of the word is still controversial. In the field of gastrointestinal endoscopy, the future of

  5. Endoscopic findings following retroperitoneal pancreas transplantation.

    Science.gov (United States)

    Pinchuk, Alexey V; Dmitriev, Ilya V; Shmarina, Nonna V; Teterin, Yury S; Balkarov, Aslan G; Storozhev, Roman V; Anisimov, Yuri A; Gasanov, Ali M

    2017-07-01

    An evaluation of the efficacy of endoscopic methods for the diagnosis and correction of surgical and immunological complications after retroperitoneal pancreas transplantation. From October 2011 to March 2015, 27 patients underwent simultaneous retroperitoneal pancreas-kidney transplantation (SPKT). Diagnostic oesophagogastroduodenoscopy (EGD) with protocol biopsy of the donor and recipient duodenal mucosa and endoscopic retrograde pancreatography (ERP) were performed to detect possible complications. Endoscopic stenting of the main pancreatic duct with plastic stents and three-stage endoscopic hemostasis were conducted to correct the identified complications. Endoscopic methods showed high efficiency in the timely diagnosis and adequate correction of complications after retroperitoneal pancreas transplantation. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Endoscopic Thyroidectomy for Differentiated Thyroid Cancer

    Directory of Open Access Journals (Sweden)

    Yi Yang

    2012-01-01

    Full Text Available Endoscopic thyroidectomy is a relatively new approach in treating differentiated thyroid cancer. Since last decades, more and more endoscopic thyroidectomies have been performed. We review the indications and contraindications, methods, and postoperational complications of this surgical procedure. Lots of surgical approaches have been developed in endoscopic thyroidectomy for differentiated thyroid cancer. Compared to conventional thyroidectomy, scarless endoscopic thyroidectomy has a superior cosmetic result. And it also reduces the incidence of hypesthesia, paresthesia, or feelings of self-consciousness. However, the outcome depends, to a large extent, on the skill of the operator and the learning curve being relatively long. With the development of surgical equipments and skills, operation time and complications will be reduced. Indications of endoscopic thyroidectomy will be widened and it will be more and more performed.

  7. Endoscopic thyroidectomy for differentiated thyroid cancer.

    Science.gov (United States)

    Yang, Yi; Gu, Xiaodong; Wang, Xiaoxiao; Xiang, Jianbin; Chen, Zongyou

    2012-01-01

    Endoscopic thyroidectomy is a relatively new approach in treating differentiated thyroid cancer. Since last decades, more and more endoscopic thyroidectomies have been performed. We review the indications and contraindications, methods, and postoperational complications of this surgical procedure. Lots of surgical approaches have been developed in endoscopic thyroidectomy for differentiated thyroid cancer. Compared to conventional thyroidectomy, scarless endoscopic thyroidectomy has a superior cosmetic result. And it also reduces the incidence of hypesthesia, paresthesia, or feelings of self-consciousness. However, the outcome depends, to a large extent, on the skill of the operator and the learning curve being relatively long. With the development of surgical equipments and skills, operation time and complications will be reduced. Indications of endoscopic thyroidectomy will be widened and it will be more and more performed.

  8. Dark-field illuminated fiber bundle endoscopy with iterative l1-min image reconstruction for honeycomb pattern removal

    Science.gov (United States)

    Liu, Xuan; Zhang, Lijun; Kirby, Mitchell; Raj, Divyaansh; Qi, Shaohai; Zhao, Feng

    2015-03-01

    In this study, we developed a dark-field illuminated reflectance fiber-optic microscope (DRFM) along with an algorithm for l1-norm minimization of fiber bundle image to provide intrinsic endoscopic imaging with cellular resolution. To suppress specular reflection from fiber bundle facets, we adopted a dark-field configuration. To remove the honeycomb pattern of fiber bundle while preserve image resolution and contrast, we chose to minimize the image l1 norm using iterative shrinkage thresholding (IST) algorithm.

  9. Settlement-Compatible Lunar Transporation

    Science.gov (United States)

    Morgenthaler, G.

    Over the past few years we have published papers in this forum identifying, characterizing and advocating settlement-compatible transportation architectures for Mars. In the present paper, we do the same for the Moon and show evolutionary potentials for growth of lunar architectures into Mars architectures of the types discussed in our previous papers. The essence of a settlement-compatible architecture is that it yields a low recurring transportation cost and that the elements of the architecture are enduring, i.e., fully reusable with lifetimes on the order of Earth-based capital investments. Our previous papers have shown that extension of human habitation to other bodies in our Solar System is probably unaffordable with any other approach. The design of a settlement-compatible architecture begins with Earth launch. In our prior papers, we simply identified the Earth launch option as a fully reusable system with roughly Shuttle (or Atlas 5 or Delta 4 or Sea Launch or Ariane 5) capability, i.e. about 20 metric t. to low Earth orbit and a payload bay of dimensions about 5 m diameter x 15 to 20 m length. This is what the commercial market needs; this is where the traffic demand is; this is approximately the design point for a next-generation (after Shuttle) reusable launch vehicle. We continue in that vein for the present paper. Human mission advocates may argue it isn't big enough; that they need 80 metric t. payload to orbit. We answer that to achieve our cost criteria, there isn't much of a choice, and that the savings in launch cost will far outweigh the added expense for on-orbit assembly. Lunar transportation is considerably less demanding than Mars transportation. The main difference is in trip time. Because lunar trips are short, the crew habitat can be small, a la the Apollo Command Module, and the propulsion system to move it is also small by comparison. We analyze and depict a lunar transportation system based on crew elements adapted from the

  10. Coating Carbon Fibers With Platinum

    Science.gov (United States)

    Effinger, Michael R.; Duncan, Peter; Coupland, Duncan; Rigali, Mark J.

    2007-01-01

    A process for coating carbon fibers with platinum has been developed. The process may also be adaptable to coating carbon fibers with other noble and refractory metals, including rhenium and iridium. The coated carbon fibers would be used as ingredients of matrix/fiber composite materials that would resist oxidation at high temperatures. The metal coats would contribute to oxidation resistance by keeping atmospheric oxygen away from fibers when cracks form in the matrices. Other processes that have been used to coat carbon fibers with metals have significant disadvantages: Metal-vapor deposition processes yield coats that are nonuniform along both the lengths and the circumferences of the fibers. The electrical resistivities of carbon fibers are too high to be compatible with electrolytic processes. Metal/organic vapor deposition entails the use of expensive starting materials, it may be necessary to use a furnace, and the starting materials and/or materials generated in the process may be hazardous. The present process does not have these disadvantages. It yields uniform, nonporous coats and is relatively inexpensive. The process can be summarized as one of pretreatment followed by electroless deposition. The process consists of the following steps: The surfaces of the fiber are activated by deposition of palladium crystallites from a solution. The surface-activated fibers are immersed in a solution that contains platinum. A reducing agent is used to supply electrons to effect a chemical reduction in situ. The chemical reduction displaces the platinum from the solution. The displaced platinum becomes deposited on the fibers. Each platinum atom that has been deposited acts as a catalytic site for the deposition of another platinum atom. Hence, the deposition process can also be characterized as autocatalytic. The thickness of the deposited metal can be tailored via the duration of immersion and the chemical activity of the solution.

  11. Electromagnetic compatibility and interference metrology

    Science.gov (United States)

    Ma, M. T.; Kanda, M.

    1986-07-01

    The material included in the report is intended for a short course on electromagnetic compatibility/interference (EMC/EM) metrology. The entire course is presented in nine chapters with the introductory part given as Chapter 1. The particular measurement topics to be covered are: (1) open sites (Chapters 2 and 6), (2) transverse electromagnetic cells (Chapter 3), (3) techniques for measuring the electromagnetic shielding of materials (Chapter 4), (4) anechoic chambers (Chapter 5), and (5) reverberating chambers (Chapter 8). In addition, since small probe antennas play an important role in some of the EMC/EMI measurements discussed, a separate chapter on various probe systems developed at NBS is given in Chapter 7. Selected contemporary EMI topics such as the characterization and measurement of a complex EM environment, interferences in the form of out-of-band receptions to an antenna, and some conducted EMI problems are also briefly discussed (Chapter 9).

  12. Novel Endoscopic Management of Obesity

    Science.gov (United States)

    Dargent, Jerome

    2016-01-01

    Endoscopic procedures have been well-documented in the obesity field, but have not yet reached a sufficient level of evidence as stand-alone methods for treating obesity. It is unclear if they should take over. Although expanding, the array of bariatric surgical techniques does not fully meet the current needs, and there are not enough resources for increasing surgery. Surgery is avoided by a majority of patients, so that less aggressive procedures are necessary. For the time being, relevant endoscopic methods include intra-gastric balloons, gastric partitioning (Endo-plication), and the metabolic field (Endo-barrier). Surgical novelties and basic research are also important contributors owing to their potential combination with endoscopy. Conditions have been listed for implementation of bariatric endoscopy, because innovation is risky, expensive, and faces ethical challenges. A scientific background is being built (e.g., hormonal studies). Some techniques require additional study, while others are not ready but should be priorities. Steps and goals include the search for conceptual similarities and the respect of an ethical frame. Minimally invasive bariatric techniques are not ready for prime time, but they are already being successful as re-do procedures. A time-frame for step-strategies can be defined, and more investments from the industry are mandatory. PMID:26855921

  13. Endoscopic diode laser therapy for chronic radiation proctitis.

    Science.gov (United States)

    Polese, Lino; Marini, Lucia; Rizzato, Roberto; Picardi, Edgardo; Merigliano, Stefano

    2018-01-01

    The purpose of this study is to determine the effectiveness of endoscopic diode laser therapy in patients presenting rectal bleeding due to chronic radiation proctitis (CRP). A retrospective analysis of CRP patients who underwent diode laser therapy in a single institution between 2010 and 2016 was carried out. The patients were treated by non-contact fibers without sedation in an outpatient setting. Fourteen patients (median age 77, range 73-87 years) diagnosed with CRP who had undergone high-dose radiotherapy for prostatic cancer and who presented with rectal bleeding were included. Six required blood transfusions. Antiplatelet (three patients) and anticoagulant (two patients) therapy was not suspended during the treatments. The patients underwent a median of two sessions; overall, a mean of 1684 J of laser energy per session was used. Bleeding was resolved in 10/14 (71%) patients, and other two patients showed improvement (93%). Only one patient, who did not complete the treatment, required blood transfusions after laser therapy; no complications were noted during or after the procedures. Study findings demonstrated that endoscopic non-contact diode laser treatment is safe and effective in CRP patients, even in those receiving antiplatelet and/or anticoagulant therapy.

  14. Digital confocal microscopy through a multimode fiber.

    Science.gov (United States)

    Loterie, Damien; Farahi, Salma; Papadopoulos, Ioannis; Goy, Alexandre; Psaltis, Demetri; Moser, Christophe

    2015-09-07

    Acquiring high-contrast optical images deep inside biological tissues is still a challenging problem. Confocal microscopy is an important tool for biomedical imaging since it improves image quality by rejecting background signals. However, it suffers from low sensitivity in deep tissues due to light scattering. Recently, multimode fibers have provided a new paradigm for minimally invasive endoscopic imaging by controlling light propagation through them. Here we introduce a combined imaging technique where confocal images are acquired through a multimode fiber. We achieve this by digitally engineering the excitation wavefront and then applying a virtual digital pinhole on the collected signal. In this way, we are able to acquire images through the fiber with significantly increased contrast. With a fiber of numerical aperture 0.22, we achieve a lateral resolution of 1.5µm, and an axial resolution of 12.7µm. The point-scanning rate is currently limited by our spatial light modulator (20Hz).

  15. Potassium methyl siliconate-treated pulp fibers and their effects on wood plastic composites: Water sorption and dimensional stability

    Science.gov (United States)

    Cheng Piao; Zhiyong Cai; Nicole M. Stark; Charles J. Monlezun

    2013-01-01

    Potassium methyl siliconate (PMS) was investigated as a new nano modifier of wood fiber and wood flour to improve the compatibility between the fiber/flour and the plastic matrix in fiber reinforced plastic composites. Before injection molding, bleached and brown pulp fibers and mixed species wood flour were pretreated in PMS solutions. The morphology of the treated...

  16. Dietary Fiber

    Science.gov (United States)

    Fiber is a substance in plants. Dietary fiber is the kind you eat. It's a type of carbohydrate. You may also see it listed on a food label as soluble ... types have important health benefits. Good sources of dietary fiber include Whole grains Nuts and seeds Fruit and ...

  17. Successes rate of endoscopic dacryocystorhinostomy at KMC.

    Science.gov (United States)

    Shrestha, S; Kafle, P K; Pokhrel, S; Maharjan, M; Toran, K C

    2010-01-01

    Nasolacrimal duct obstruction is a common problem which can be corrected by dacryocystorhinostomy (DCR). The gold standard treatment for this is DCR operation through an external approach. Development of endoscopic sinus surgery and endoscopic DCR performed through intranasal route is a major recent development in this field. The aim of this study is to find out the success rate of endoscopic dacryocystorhinostomy without silicon stent intubation within the period of six month following surgery. A prospective study was done on 26 patients with obstruction of the nasolacrimal duct referred from eye out-patient department to ENT OPD during one year period from 2008 to 2009. All the cases had undergone endoscopic DCR operation which was regularly followed up for a period of six months. Postoperative patency of ostium was checked by sac syringing and endoscopic visualisation of ostium in the nasal cavity. The success of surgery was categorised as: complete cure, partial cure and no improvement depending upon symptomatic relief and clinical examination such as sac syringing and endoscopic examination following surgery. In six months' follow-up, 22 (84.5%) out of 26 patients had achieved the complete cure and 4 patients (15.5%) continued to have persistent epiphora. Endoscopic DCR is a beneficial procedure for nasolacrimal duct obstruction with no external scar on face and less bleeding. The success rate is as good as external DCR.

  18. Endoscopic retrograde cholangiopancreatography for primary sclerosing cholangitis.

    Science.gov (United States)

    Thosani, Nirav; Banerjee, Subhas

    2014-11-01

    Although there are no randomized, controlled trials evaluating the efficacy of endoscopic retrograde cholangiography (ERC) in primary sclerosing cholangitis (PSC) patients, substantial indirect evidence supports the effectiveness of ERC in symptomatic PSC patients with a dominant stricture. Currently, cumulative evidence supports the role of ERC with endoscopic dilation with or without additional short-term stent placement for symptomatic PSC patients with a dominant stricture. Differentiating benign dominant strictures from cholangiocarcinoma (CCA) remains difficult; however, newer endoscopic techniques and advanced cytologic techniques are likely to improve sensitivity for the diagnosis of CCA over that achieved by traditional cytology brushing alone. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Direct percutaneous endoscopic jejunostomy performed with gastroscope

    Directory of Open Access Journals (Sweden)

    Ajay P Choksi

    2013-01-01

    Full Text Available While percutaneous endoscopic gastrostomy (PEG is a well-known approach for achieving enteral feeding, direct percutaneous endoscopic jejunostomy (DPEJ is a technique that allows endoscopic placement of percutaneous/transabdominal feeding tube directly into the jejunum. It offers a non-surgical alternative for postpyloric enteral feeding for long-term nutritional support when gastric feeding is not technically possible or is inappriopriate. Conventionally DPEJ is done with pediatric colonoscope or small bowel enteroscope. Here, we report a case where DPEJ was accomplished with gastroscope.

  20. Endoscopic intervention in obstructive renal papillary necrosis

    Directory of Open Access Journals (Sweden)

    V Chandrashekar Rao

    2004-01-01

    Full Text Available To evaluate the usefulness of ultrasonography, endoscopic retrieval, and the outcome of patients with diabetes mellitus presenting with ureteric obstruction caused by necrosed renal papillae. Material And Methods: Eleven seriously ill patients with diabetes mellitus, admitted into medical wards, were found to have ureteric obstruction complicated by urinary infection. The diagnosis was made by ultrasonography alone. Prompt relief followed endoscopic extraction of the offending necrosed papillae. Results: Ten patients improved dramatically. One patient died from septicemia. Conclusions: Ultrasonography appears to be a useful diagnostic method to diagnose ureteric obstruction. It is cheap, fast, and extremely reliable. Endoscopic extraction of the obstructing papilla offers the best chance for successful outcome.

  1. Vacuum Compatible Percussive Dynamic Cone Penetrometer Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Honeybee Robotics proposes to develop a vacuum compatible percussive dynamic cone penetrometer (PDCP), for establishing soil bin characteristics, with the ultimate...

  2. Clinical endoscopic management and outcome of post-endoscopic sphincterotomy bleeding.

    Directory of Open Access Journals (Sweden)

    Wei-Chen Lin

    Full Text Available Post-endoscopic sphincterotomy bleeding is a common complication of biliary sphincterotomy, and the incidence varies from 1% to 48%. It can be challenging to localize the bleeder or to administer various interventions through a side-viewing endoscope. This study aimed to evaluate the risk factors of post-endoscopic sphincterotomy bleeding and the outcome of endoscopic intervention therapies. We retrospectively reviewed the records of 513 patients who underwent biliary sphincterotomy in Mackay Memorial Hospital between 2011 and 2016. The blood biochemistry, comorbidities, indication for sphincterotomy, severity of bleeding, endoscopic features of bleeder, and type of endoscopic therapy were analyzed. Post-endoscopic sphincterotomy bleeding occurred in 65 (12.6% patients. Forty-five patients had immediate bleeding and 20 patients had delayed bleeding. The multivariate analysis of risk factors associated with post-endoscopic sphincterotomy bleeding were liver cirrhosis (P = 0.029, end-stage renal disease (P = 0.038, previous antiplatelet drug use (P<0.001, and duodenal ulcer (P = 0.023. The complications of pancreatitis and cholangitis were higher in the bleeding group, with statistical significance. Delayed bleeding occurred within 1 to 7 days (mean, 2.5 days, and 60% (12/20 of the patients received endoscopic evaluation. In the delayed bleeding group, the successful hemostasis rate was 71.4% (5/7, and 65% (13/20 of the patients had ceased bleeding without endoscopic hemostasis therapy. Comparison of different therapeutic modalities showed that cholangitis was higher in patients who received epinephrine spray (P = 0.042 and pancreatitis was higher in patients who received epinephrine injection and electrocoagulation (P = 0.041 and P = 0.039 respectively. Clinically, post-endoscopic sphincterotomy bleeding and further endoscopic hemostasis therapy increase the complication rate of pancreatitis and cholangitis. Realizing the effectiveness of each

  3. Minimal form factor digital-image sensor for endoscopic applications

    Science.gov (United States)

    Wäny, Martin; Voltz, Stephan; Gaspar, Fabio; Chen, Lei

    2009-02-01

    This paper presents a digital image sensor SOC featuring a total chip area (including dicing tolerances) of 0.34mm2 for endoscopic applications. Due to this extremely small form factor the sensor enables integration in endoscopes, guide wires and locater devices of less than 1mm outer diameter. The sensor embeds a pixel matrix of 10'000 pixels with a pitch of 3um x 3um covered with RGB filters in Bayer pattern. The sensor operates fully autonomous, controlled by an on chip ring oscillator and readout state machine, which controls integration AD conversion and data transmission, thus the sensor only requires 4 pin's for power supply and data communication. The sensor provides a frame rate of 40Frames per second over a LVDS serial data link. The endoscopic application requires that the sensor must work without any local power decoupling capacitances at the end of up to 2m cabling and be able to sustain data communication over the same wire length without deteriorating image quality. This has been achieved by implementation of a current mode successive approximation ADC and current steering LVDS data transmission. An band gap circuit with -40dB PSRR at the data frequency was implemented as on chip reference to improve robustness against power supply ringing due to the high series inductance of the long cables. The B&W versions of the sensor provides a conversion gain of 30DN/nJ/cm2 at 550nm with a read noise in dark of 1.2DN when operated at 2m cable. Using the photon transfer method according to EMVA1288 standard the full well capacity was determined to be 18ke-. According to our knowledge the presented work is the currently world smallest fully digital image sensor. The chip was designed along with a aspheric single surface lens to assemble on the chip without increasing the form factor. The extremely small form factor of the resulting camera permit's to provide visualization with much higher than state of the art spatial resolution in sub 1mm endoscopic

  4. Micro-ureteroscopy: Initial experience in the endoscopic treatment of pelvic ureteral lithiasis.

    Science.gov (United States)

    Caballero, J P; Galán, J A; Verges, A; Amorós, A; Garcia-Segui, A

    2015-06-01

    To present to report the first case of ureteral lithiasis resolved using a new endoscopic approach, which we call microureteroscopy (m-URS) and attempts to reduce the ureteral damage caused by conventional instrumentation. We selected a 53-year-old patient with a 16-mm calculus in the right distal ureter. For endoscopic access, we used a 4.8 Fr sheath from the microperc set and fragmented the stone with a 230-micron laser fiber. Complete fragmentation of the stone was achieved. We placed a JJ catheter due to significant ureteral edema. The surgical time and postsurgical stay were 156minutes and 24hours, respectively. There were no complications, the requirements for analgesia were minimal, and the patient was free of residual stones. The m-URS technique is feasible, simple and effective for the treatment of pelvic ureteral lithiasis in women and optimizes minimal invasion, with results that can be comparable to conventional endoscopic techniques in terms of ease of access and quality of endoscopic vision without affecting the resolution capacity. Larger studies and greater technological development is needed to define the definitive role of this procedure. Currently, its major limitations lie in the treatment of proximal ureter lithiasis and in the treatment of men. This technique could also be a viable alternative for pediatric patients. Copyright © 2014 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  5. How current ginning processes affect fiber length uniformity index

    Science.gov (United States)

    There is a need to develop cotton ginning methods that improve fiber characteristics that are compatible with the newer and more efficient spinning technologies. A literature search produced recent studies that described how current ginning processes affect HVI fiber length uniformity index. Resul...

  6. Tone compatibility between HDR displays

    Science.gov (United States)

    Bist, Cambodge; Cozot, Rémi; Madec, Gérard; Ducloux, Xavier

    2016-09-01

    High Dynamic Range (HDR) is the latest trend in television technology and we expect an in ux of HDR capable consumer TVs in the market. Initial HDR consumer displays will operate on a peak brightness of about 500-1000 nits while in the coming years display peak brightness is expected to go beyond 1000 nits. However, professionally graded HDR content can range from 1000 to 4000 nits. As with Standard Dynamic Range (SDR) content, we can expect HDR content to be available in variety of lighting styles such as low key, medium key and high key video. This raises concerns over tone-compatibility between HDR displays especially when adapting to various lighting styles. It is expected that dynamic range adaptation between HDR displays uses similar techniques as found with tone mapping and tone expansion operators. In this paper, we survey simple tone mapping methods of 4000 nits color-graded HDR content for 1000 nits HDR displays. We also investigate tone expansion strategies when HDR content graded in 1000 nits is displayed on 4000 nits HDR monitors. We conclude that the best tone reproduction technique between HDR displays strongly depends on the lighting style of the content.

  7. Design of a small animal MR compatible PET scanner

    Energy Technology Data Exchange (ETDEWEB)

    Slates, R.; Cherry, S.; Boutefnouchet, A.; Shao, Y.; Dahlbom, M.; Farahani, K. [Univ. of California, Los Angeles, CA (United States). School of Medicine

    1999-06-01

    Using a combination of Monte-Carlo simulations and experimental measurements, the authors have designed a small animal MR compatible PET (McPET) scanner for simultaneous PET and MR imaging of mice and rats in vivo. The scanner consists of one ring of 480 LSO crystals arranged in 3 layers with 160 crystals per layer. The crystal dimensions are 2 x 3 x 7.5 mm{sup 3}. This was based on a target resolution of 2.5 mm and simulations showing that a depth of 7.5 mm avoided significant depth of interaction effects across the desired field of view. The system diameter of 11.2 cm is large enough to accommodate the animal positioned inside a stereotactic frame. Each crystal will be coupled through 2 mm diameter optical fibers to multi-channel PMT`s which reside outside the main magnetic field. Through 50 cm of optical fiber, a photopeak is clearly seen and the measured energy resolution is 25%. Prototype optical fiber connectors have been tested to increase the flexibility of the system and result in a light loss of only 6%. The proposed system will have adequate resolution and sensitivity for a number of applications in small animals and will be the first practical device for simultaneous in vivo imaging with PET and MR.

  8. Ensuring the Safety of Your Endoscopic Procedure

    Science.gov (United States)

    ... been a major advance in the treatment of gastrointestinal diseases. For example, the use of endoscopes allows the detection of ulcers, cancers, polyps, and sites of internal bleeding. Through endoscopy, tissue ...

  9. Endoscopic appearance of irradiated gastric mucosa

    Energy Technology Data Exchange (ETDEWEB)

    De Sagher, L.I.; Van den Heule, B.; Van Houtte, P.; Engelholm, L.; Balikdjan, D.; Bleiberg, H.

    1979-09-01

    Irradiation of the epigastric area for gastric cancer may induce actinic lesions of the stomach characterized on endoscopic examination by ulcerations, haemorrhagic gastritis, fragility of the mucosa, thickening and congestion of the gastric folds.

  10. An illumination system for endoscopic applications

    DEFF Research Database (Denmark)

    2013-01-01

    The present disclosure relates to an illumination system for endoscopic applications comprising at least one substantially monochromatic light source having a predefined central wavelength between 400 and 500 nm or between 500 and 550 nm, an optical transmission path adapted to guide light...... emanating from the light source to an endoscopic region of examination, and an optical band-rejection filter, wherein the illumination system is adapted to illuminate at least a part of the region of examination by generating autofluorescence in surrounding tissue, and the band-rejection filter is adapted...... to attenuate at least said light source wavelength to a viewer and wherein said light source is the single light source in the illumination system. A further embodiment relates to an endoscope for examining a body cavity comprising tissue, the endoscope comprising a source of light consisting...

  11. Endoscopic discovery and capture of Taenia saginata.

    Science.gov (United States)

    Descombes, P; Dupas, J L; Capron, J P

    1981-01-01

    The authors report the first case of endoscopic finding and removal of a beef tapeworm (Taenia saginata). The parasite was discovered in the duodenal bulb of a 72-year-old woman, who complained of epigastric pain.

  12. Society of American Gastrointestinal and Endoscopic Surgeons

    Science.gov (United States)

    ... for Minimizing Bile Duct Injuries: Adopting a Universal Culture of Safety in Cholecystectomy https://www.youtube.com/ ... Surgeons: The New SAGES Course Endorsement System The Society of American Gastrointestinal Endoscopic Surgeons (SAGES) recognizes that ...

  13. Laparoscopic-assisted percutaneous endoscopic transgastrostomy jejunostomy

    National Research Council Canada - National Science Library

    Dimofte, Mihail-Gabriel; Porumb, Vlad; Nicolescu, Simona; Ristescu, Irina; Lunca, Sorinel

    2014-01-01

    .... The typical approach involves a percutaneous endoscopic transgastrostomy jejunostomy (PEG-J), which requires a combination of procedures designed to ensure that no organ is interposed between the abdominal wall and the gastric surface...

  14. Short-pulse propagation in fiber optical parametric amplifiers

    DEFF Research Database (Denmark)

    Cristofori, Valentina

    Fiber optical parametric amplifiers (FOPAs) are attractive because they can provide large gain over a broad range of central wavelengths, depending only on the availability of a suitable pump laser. In addition, FOPAs are suitable for the realization of all-optical signal processing functionalities...... is implemented to obtain an all-fiber system. The advantages of all fiber-systems are related to their reliability, long-term stability and compactness. Fiber optical parametric chirped pulse amplification is promising for the amplification of such signals thanks to the inherent compatibility of FOPAs with fiber...

  15. Cellular compatibility of RGD-modified chitosan nanofibers with aligned or random orientation

    Energy Technology Data Exchange (ETDEWEB)

    Wang Yanyan; Lue Lanxin; Feng Zhangqi; Xiao Zhongdang; Huang Ningping, E-mail: nphuang@seu.edu.c, E-mail: zdxiao@seu.edu.c [State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096 (China)

    2010-10-01

    Aligned and randomly oriented chitosan nanofibers were prepared by electrospinning. The fibers were modified with the RGD cell-adhesive peptide through a heterobifunctional crosslinker containing a segment of poly(ethylene glycol) (PEG). PEG rendered the surface hydrophilic and provided flexible spacers, allowing the preservation of the bioactivity of further captured RGD peptides. NIH 3T3 cells were used to test the cellular compatibility of these chitosan nanofibrous scaffolds. Cell morphology and viability were investigated by SEM, fluorescent staining and cell counting. The results indicate that RGD-modified surfaces significantly improve the cellular compatibility of chitosan nanofibers and suggest a good candidate as a scaffold employed in tissue engineering.

  16. Endoscopic and Radiologic Findings in Eosinophilic Esophagitis.

    Science.gov (United States)

    Alexander, Jeffrey A

    2018-01-01

    Eosinophilic esophagitis (EoE) was first described by Landis in 1978. The disease is characterized by esophageal symptoms, primarily dysphagia in adult patients, and esophageal eosinophilic infiltration. The disease is associated with characteristic endoscopic findings, including edema, rings, furrows, exudates, and strictures. The typical radiographic findings of this disorder are rings, strictures, and small-caliber esophagus. The endoscopic and radiographic findings of EoE are the topic of this review. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Tracking camera control in endoscopic dacryocystorhinostomy surgery.

    Science.gov (United States)

    Wawrzynski, J R; Smith, P; Tang, L; Hoare, T; Caputo, S; Siddiqui, A A; Tsatsos, M; Saleh, G M

    2015-12-01

    Poor camera control during endoscopic dacryocystorhinostomy (EnDCR) surgery can cause inadequate visualisation of the anatomy and suboptimal surgical outcomes. This study investigates the feasibility of using computer vision tracking in EnDCR surgery as a potential formative feedback tool for the quality of endoscope control. A prospective cohort analysis was undertaken comparing junior versus senior surgeons performing routine EnDCR surgery. Computer vision tracking was applied to endoscopic video footage of the surgery: Total number of movements, camera path length in pixels and surgical time were determined for each procedure. A Mann-Whitney U-test was used to test for a significant difference between juniors and seniors (P theatre. Ten junior surgeons (100 completed procedures). Total number of movements of the endoscope per procedure. Path length of the endoscope per procedure. Twenty videos, 10 from junior surgeons and 10 from senior surgeons were analysed. Feasibility of our tracking system was demonstrated. Mean camera path lengths were significantly different at 119,329px (juniors) versus 43,697px (seniors), P ≪ 0.05. The mean number of movements was significantly different at 9134 (juniors) versus 3690 (seniors), P ≪ 0.05. These quantifiable differences demonstrate construct validity for computer vision endoscope tracking as a measure of surgical experience. Computer vision tracking is a potentially useful structured and objective feedback tool to assist trainees in improving endoscope control. It enables juniors to examine how their pattern of endoscope control differs from that of seniors, focusing in particular on sections where they are most divergent. © 2015 John Wiley & Sons Ltd.

  18. Endoscopic Sinus Surgery for Chronic Sinusitis

    OpenAIRE

    篠, 昭男; 吉原, 俊雄; Akio, SHINO; Toshio, YOSHIHARA

    2004-01-01

    Endoscopic sinus surgery (ESS) has became basic surgical treatment for chronic sinusitis instead of the Caldwell-Luc procedure. This technique is aimed at improvement of ventilation and excretion with endoscopic approach between nasal cavity and each sinus. The mucosa preservation of sinus is recognized to important as the surgery for inflammatory disease. The ostiomeatal complex (OMC) plays a significant role in the pathogenesis of sinusitis. Obstruction here predisposes to chronic sinusitis...

  19. Endoscopic intervention in obstructive renal papillary necrosis

    OpenAIRE

    V Chandrashekar Rao; Bhat, Soumya S; Padmanabha Vijayan; Shankar Ramamurthy

    2004-01-01

    To evaluate the usefulness of ultrasonography, endoscopic retrieval, and the outcome of patients with diabetes mellitus presenting with ureteric obstruction caused by necrosed renal papillae. Material And Methods: Eleven seriously ill patients with diabetes mellitus, admitted into medical wards, were found to have ureteric obstruction complicated by urinary infection. The diagnosis was made by ultrasonography alone. Prompt relief followed endoscopic extraction of the offending necrosed pa...

  20. 32 CFR 552.95 - Compatible use.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 3 2010-07-01 2010-07-01 true Compatible use. 552.95 Section 552.95 National... CEMETERIES REGULATIONS AFFECTING MILITARY RESERVATIONS Fort Lewis Land Use Policy § 552.95 Compatible use. (a... closed. (4) Motorized infantry operations that will use the majority of the road net in a training area...

  1. Common fixed points for weakly compatible maps

    Indian Academy of Sciences (India)

    The purpose of this paper is to prove a common fixed point theorem, from the class of compatible continuous maps to a larger class of maps having weakly compatible maps without appeal to continuity, which generalized the results of Jungck [3], Fisher [1], Kang and Kim [8], Jachymski [2], and Rhoades [9].

  2. Is Religious Education Compatible with Science Education?

    Science.gov (United States)

    Mahner, Martin; Bunge, Mario

    1996-01-01

    Addresses the problem of the compatibility of science and religion, and its bearing on science and religious education, challenges the popular view that science and religion are compatible or complementary. Discusses differences at the doctrinal, metaphysical, methodological, and attitudinal levels. Argues that religious education should be kept…

  3. Endoscopic Management of Gastrointestinal Leaks and Fistulae.

    Science.gov (United States)

    Willingham, Field F; Buscaglia, Jonathan M

    2015-10-01

    Gastrointestinal leaks and fistulae can be serious acute complications or chronic morbid conditions resulting from inflammatory, malignant, or postsurgical states. Endoscopic closure of gastrointestinal leaks and fistulae represents major progress in the treatment of patients with these complex presentations. The main goal of endoscopic therapy is the interruption of the flow of luminal contents across a gastrointestinal defect. In consideration of the proper endoscopic approach to luminal closure, several basic principles must be considered. Undrained cavities and fluid collections must often first be drained percutaneously, and the percutaneous drain provides an important measure of safety for subsequent endoscopic luminal manipulations. The size and exact location of the leak/fistula, as well as the viability of the surrounding tissue, must be defined. Almost all complex leaks and fistulae must be approached in a multidisciplinary manner, collaborating with colleagues in nutrition, radiology, and surgery. Currently, gastrointestinal leaks and fistulae may be managed endoscopically by using 1 or more of the following modalities: stent placement, clip closure (including through-the-scope clips and over-the-scope devices), endoscopic suturing, and the injection of tissue sealants. In this article, we discuss these modalities and review the published outcomes data regarding each approach as well as practical considerations for successful closure of luminal defects. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.

  4. Endoscopic solutions to challenging enteral feeding problems.

    Science.gov (United States)

    Paski, Shirley C; Dominitz, Jason A

    2012-09-01

    Enteral nutrition support is often required in patients who are unable to meet their own nutritional requirements. Endoscopists play a key role in the placement of enteral feeding catheters. This review focuses on the recently published solutions to common problems encountered during endoscopic placement of enteral feeding devices. Case reports and case series describe solutions for overcoming common problems encountered during the placement of enteral feeding devices. Transnasal techniques can simplify nasojejunal tube placement, whereas deep enteroscopy techniques provide more reliable jejunostomy placement. Endoscopic ultrasound can help when transillumination is not possible or in the setting of postsurgical anatomy like Roux-en-Y. Laparoscopic-assisted procedures are useful when endoscopic techniques have failed in adults or in select high-risk pediatric patients. The American Society for Gastrointestinal Endoscopy and the American Gastroenterology Association both published comprehensive guidelines that outline the indications, contraindications, technical aspects of feeding catheter placement, and complications. Advances in endoscopic techniques, including deep enteroscopy, endoscopic ultrasound, ultra-slim transnasal endoscopes and laparoscopic-assisted procedures, have enabled endoscopists to successfully place enteral feeding tubes in patients who previously required open procedures.

  5. Role of endoscopic ultrasound and endoscopic resection for the treatment of gastric schwannoma.

    Science.gov (United States)

    Hu, Jinlong; Liu, Xiang; Ge, Nan; Wang, Sheng; Guo, Jintao; Wang, Guoxin; Sun, Siyu

    2017-06-01

    Endoscopic ultrasound (EUS) and endoscopic resection play an important role in gastric submucosal tumor. However, there were few articles regarding EUS and endoscopic resection of gastric schwannomas. Our aim was to evaluate the role of EUS and endoscopic resection in treating gastric schwannomas.We retrospectively reviewed 14 patients between March 2012 and April 2016 with gastric schwannomas and who received EUS and endoscopic resection. EUS characteristics, endoscopic resection, tumor features, and follow-up were evaluated in all the patients.Fourteen patients were enrolled in the present study. The patients' ages ranged from 25 to 72 years (mean age, 52.6 years). On EUS, all tumors were originating from muscularis propria and hypoechoic. Ten tumors have the extraluminal growth patterns and 4 tumors have the intraluminal growth patterns. Marginal halos were observed in 7 lesions. No cystic change and calcification were found inside the lesions. Complete endoscopic resection was performed in all the patients with no complications occurring in any patients. No recurrence or metastases was found in all patients during the follow-up period.Gastric schwannoma has some characteristics on EUS, but it is difficult to differentiate gastric schwannoma from gastrointestinal stromal tumor. Endoscopic resection is an effective and safe treatment for gastric schwannoma with an excellent follow-up outcome.

  6. Towards automated visual flexible endoscope navigation.

    Science.gov (United States)

    van der Stap, Nanda; van der Heijden, Ferdinand; Broeders, Ivo A M J

    2013-10-01

    The design of flexible endoscopes has not changed significantly in the past 50 years. A trend is observed towards a wider application of flexible endoscopes with an increasing role in complex intraluminal therapeutic procedures. The nonintuitive and nonergonomical steering mechanism now forms a barrier in the extension of flexible endoscope applications. Automating the navigation of endoscopes could be a solution for this problem. This paper summarizes the current state of the art in image-based navigation algorithms. The objectives are to find the most promising navigation system(s) to date and to indicate fields for further research. A systematic literature search was performed using three general search terms in two medical-technological literature databases. Papers were included according to the inclusion criteria. A total of 135 papers were analyzed. Ultimately, 26 were included. Navigation often is based on visual information, which means steering the endoscope using the images that the endoscope produces. Two main techniques are described: lumen centralization and visual odometry. Although the research results are promising, no successful, commercially available automated flexible endoscopy system exists to date. Automated systems that employ conventional flexible endoscopes show the most promising prospects in terms of cost and applicability. To produce such a system, the research focus should lie on finding low-cost mechatronics and technologically robust steering algorithms. Additional functionality and increased efficiency can be obtained through software development. The first priority is to find real-time, robust steering algorithms. These algorithms need to handle bubbles, motion blur, and other image artifacts without disrupting the steering process.

  7. Endoscopic Management of Nonlifting Colon Polyps

    Directory of Open Access Journals (Sweden)

    Shai Friedland

    2013-01-01

    Full Text Available Background and Study Aims. The nonlifting polyp sign of invasive colon cancer is considered highly sensitive and specific for cancer extending beyond the mid-submucosa. However, prior interventions can cause adenomas to become nonlifting due to fibrosis. It is unclear whether nonlifting adenomas can be successfully treated endoscopically. The aim of this study was to evaluate outcomes in a referral practice incorporating a standardized protocol of attempted endoscopic resection of nonlifting lesions previously treated by biopsy, polypectomy, surgery, or tattoo placement. Patients and Methods. Retrospective review of patients undergoing colonoscopy by one endoscopist at two hospitals found to have nonlifting lesions from prior interventions. Lesions with biopsy proven invasive cancer or definite endoscopic features of invasive cancer were excluded. Lesions ≥ 8 mm were routinely injected with saline prior to attempted endoscopic resection. Polypectomy was performed using a stiff snare, followed by argon plasma coagulation (APC if necessary. Results. 26 patients each had a single nonlifting lesion with a history of prior intervention. Endoscopic resection was completed in 25 (96%. 22 required snare resection and APC. 1 patient had invasive cancer and was referred for surgery. The recurrence rate on follow-up colonoscopy was 26%. All of the recurrences were successfully treated endoscopically. There was 1 postprocedure bleed (4%, no perforations, and no other complications. Conclusions. The majority of adenomas that are nonlifting after prior interventions can be treated successfully and safely by a combination of piecemeal polypectomy and ablation. Although recurrence rates are high at 26%, these too can be successfully treated endoscopically.

  8. Improvement in mechanical properties of glass fiber fabric/PVC composites with chopped glass fibers and coupling agent

    Science.gov (United States)

    Lee, Jaewoong; Park, Su Bin; Lee, Joon Seok; Kim, Jong Won

    2017-07-01

    Glass fiber reinforced polyvinylchloride (PVC) composite is used widely because of its low price, chemical resistance, and dimensional stability, but most are short fiber reinforced PVC composites. Fabric reinforced composite have undulated regions, which is the only region without fiber, due to the characteristics of the weave construction, and it limits increasing the mechanical properties. Therefore, in this study, to increase the mechanical properties, the undulated regions of the glass fiber fabric/PVC composite were filled with a silane coupling agent treated chopped fiber. The physical properties, dynamic mechanical thermal properties, and mechanical properties of the prepared composite were observed. The critical fiber aspect ratio of the chopped fiber is different for each mechanical property. This shows that the fabric-reinforced composite of chopped fibers affect each of the mechanical properties differently. In addition, the silane coupling treatment increases the compatibility of the composite components, improving the mechanical properties.

  9. A 3D scanning laser endoscope architecture utilizing a circular piezoelectric membrane

    Science.gov (United States)

    Khayatzadeh, Ramin; Çivitci, Fehmi; Ferhanoğlu, Onur

    2017-12-01

    A piezo-scanning fiber endoscopic device architecture is proposed for 3D imaging or ablation. The endoscopic device consists of a piezoelectric membrane that is placed perpendicular to the optical axis, a fiber optic cable that extends out from and actuated by the piezoelectric membrane, and one or multiple lenses for beam delivery and collection. Unlike its counterparts that utilize piezoelectric cylinders for fiber actuation, the proposed architecture offers quasi-static actuation in the axial direction along with resonant actuation in the lateral directions forming a 3D scanning pattern, allowing adjustment of the focus plane. The actuation of the four-quadrant piezoelectric membrane involves driving of two orthogonal electrodes with AC signals for lateral scanning, while simultaneously driving all electrodes for axial scanning and focus adjustment. We have characterized piezoelectric membranes (5 -15mm diameter) with varying sizes to monitor axial displacement behavior with respect to applied DC voltage. We also demonstrate simultaneous lateral and axial actuation on a resolution target, and observe the change of lateral resolution on a selected plane through performing 1D cross-sectional images, as an indicator of focal shift through axial actuation. Based on experimental results, we identify the optical and geometrical parameters for optimal 3D imaging of tissue samples. Our findings reveal that a simple piezoelectric membrane, having comparable dimensions and drive voltage requirement with off-the-shelf MEMS scanner chips, offers tissue epithelial imaging with sub-cellular resolution.

  10. Sequelae of Endoscopic Inguinal Hernia Repair : Incidence, evaluation and management

    NARCIS (Netherlands)

    Burgmans, J.P.J.

    2015-01-01

    The endoscopic preperitoneal technique (TEP) is an appealing inguinal hernia repair technique, theoretically superior to other approaches. In practice some problems remain unsolved. Real incidences of chronic postoperative inguinal pain (CPIP) and other important sequelae of endoscopic hernia repair

  11. Endoscopic Radial Artery Harvest for Coronary Artery Bypass Surgery

    Directory of Open Access Journals (Sweden)

    Kuan-Ming Chiu

    2006-01-01

    Conclusion: Endoscopic harvest of the radial artery is technically demanding, but excellent results can be achieved. The endoscopic approach can provide suitable conduits in a less invasive way than the open harvest technique.

  12. Is bacteriologic surveillance in endoscope reprocessing stringent enough?

    NARCIS (Netherlands)

    Kovaleva, J.; Meessen, N. E. L.; Peters, F. T. M.; Been, M. H.; Arends, J. P.; Borgers, R. P.; Degener, J. E.

    2009-01-01

    Endoscopes, including duodenoscopes, are medical devices that are frequently associated with outbreaks of nosocomial infections. We investigated an outbreak of multidrug-resistant Pseudomonos aeruginosa sepsis affecting three patients after endoscopic retrograde cholangiopancreaticography (ERCP).

  13. Transforaminal endoscopic surgery for lumbar stenosis: a systematic review

    NARCIS (Netherlands)

    Nellensteijn, J.M.; Ostelo, R.W.J.G.; Bartels, R.; Peul, W.; van Royen, B.J.; van Tulder, M.W.

    2010-01-01

    Transforaminal endoscopic techniques have become increasingly popular in surgery of patients with lumbar stenosis. The literature has not yet been systematically reviewed. A comprehensive systematic literature review up to November 2009 to assess the effectiveness of transforaminal endoscopic

  14. Laparoscopic-assisted percutaneous endoscopic transgastrostomy jejunostomy.

    Science.gov (United States)

    Dimofte, Mihail-Gabriel; Porumb, Vlad; Nicolescu, Simona; Ristescu, Irina; Lunca, Sorinel

    2014-01-01

    New therapeutic protocols for patients with end-stage Parkinson disease include a carbidopa/levodopa combination using continuous, modulated enteral administration via a portable pump. The typical approach involves a percutaneous endoscopic transgastrostomy jejunostomy (PEG-J), which requires a combination of procedures designed to ensure that no organ is interposed between the abdominal wall and the gastric surface. Lack of transillumination in maximal endoscopic light settings is a major contraindication for PEG-J, and we decided to use a different approach to establish enteric access for long-term medication delivery via pump, using a minimally invasive procedure. In all patients, we performed a laparoscopic-assisted percutaneous transgastrostomy jejunostomy (LAPEG-J) after an unsuccessful endoscopic transillumination. Five patients with end-stage Parkinson disease were referred to our department after successful therapeutic testing with administration of levodopa/carbidopa via naso-jejunal tube. All patients failed the endoscopic transillumination during the endoscopic procedure and were considered for LAPEG-J. In all patients, the LAPEG-J procedure was uneventful. The most common reason identified for failed transillumination was a high position of the stomach, followed by interposition of the liver or colon between the stomach and anterior abdominal wall. There were no complications regarding the LAPEG-J procedure, and all patients were discharged during the second postprocedural day. LAPEG-J provides a simple and safe option for placing a jejunostomy after an unsuccessful PEG-J attempt.

  15. DOD Offshore Wind Mission Compatibility Assessments

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set represents the results of analyses conducted by the Department of Defense to assess the compatibility of offshore wind development with military assets...

  16. Morgantown People Mover Electromagnetic Compatibility Program

    Science.gov (United States)

    1980-09-01

    Electromagnetic Compatibility (EMC) of a transit system is the absence of interference between all parts of the system, and between the system and the community which it serves. This report documents the EMC experience obtained during the design and ...

  17. Advanced Microgravity Compatible, Integrated Laundry System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — An Advanced Microgravity Compatible, Integrated laundry System (AMCILS) is proposed that uses a two phase water / water vapor system to allow good agitation of...

  18. Electromagnetic theory for electromagnetic compatibility engineers

    CERN Document Server

    Toh, Tze-Chuen

    2013-01-01

    Engineers and scientists who develop and install electronic devices and circuits need to have a solid understanding of electromagnetic theory and the electromagnetic behavior of devices and circuits. In particular, they must be well-versed in electromagnetic compatibility, which minimizes and controls the side effects of interconnected electric devices. Designed to entice the practical engineer to explore some worthwhile mathematical methods, and to reorient the theoretical scientist to industrial applications, Electromagnetic Theory for Electromagnetic Compatibility Engineers is based on the

  19. Psychological compatibility of women's handball team

    Directory of Open Access Journals (Sweden)

    Shalar O.G.

    2010-02-01

    Full Text Available The results of study of psychological compatibility of womanish handball commands are presented. The psychological climate of command is investigational. Certain and adapted methods of estimation of psychological compatibility in the command playing types of sport. Psychological tests allow to expose the strong and weak sides of psychology of sportsmen. These information can be used for more effective program of psychological preparation of sportsmen development. It is necessary to improve determination of separate individual qualities of personality of sportsmen.

  20. Postoperative seizure following transforaminal percutaneous endoscopic lumbar discectomy

    OpenAIRE

    Kertmen, Hayri; G?rer, Bora; YILMAZ, Erdal Resit; Sekerci, Zeki

    2016-01-01

    Endoscopic surgery for lumbar disc herniation has been available for more than 30 years. Transforaminal percutaneous endoscopic lumbar discectomy is a well-known, safe, and effective method used for the treatment of the lumbar disc herniation. The published complications of the transforaminal percutaneous endoscopic lumbar discectomy consist of infections, thrombophlebitis, dysesthesia, dural tear, vascular injury, and death. Seizure after transforaminal percutaneous endoscopic lumbar discect...

  1. Endoscopic sleeve gastroplasty: a potential endoscopic alternative to surgical sleeve gastrectomy for treatment of obesity.

    Science.gov (United States)

    Abu Dayyeh, Barham K; Rajan, Elizabeth; Gostout, Christopher J

    2013-09-01

    Obesity and its associated conditions, including type 2 diabetes and cardiovascular disease, have reached epidemic proportions. High-efficacy, high-risk surgical approaches are unlikely to meet the increasing burden of disease. Emerging endoscopic technologies have opened the door for endoscopic approaches to reproduce many of the benefits of GI weight loss surgery and thereby contribute to the effective treatment of obesity and its associated disorders. To demonstrate the technical feasibility of transoral endoscopic gastric volume reduction with an endoscopic suturing device in a fashion similar to sleeve gastrectomy for the treatment of obesity. Single-center, pilot feasibility study. Four human subjects with obesity. Transoral sleeve gastroplasty. Technical feasibility. We successfully used an endoscopic free-hand suturing system in 4 subjects, thus demonstrating the technical feasibility of a novel technique to mimic the anatomic manipulations created by surgical sleeve gastrectomy endoscopically. Pilot feasibility study with small number of subjects. Endoscopic sleeve gastroplasty for treatment of obesity is feasible. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  2. Compatibility studies for the waste packaging program

    Energy Technology Data Exchange (ETDEWEB)

    Fullam, H.T.

    1969-03-01

    A program is now underway by Battelle-Northwest to develop the technology required for a waste packaging plant. Cesium chloride and strontium fluoride have been selected as the prime candidates for packaging. Cesium diuranate and strontium pyrophosphate have been selected as backup compounds for packaging in case either or both of the prime candidates should be rejected for any reason. No detailed studies of CsCl compatibility have been reported and long term data are needed. As in the case with CsCl, no detailed studies have been made on SrF{sub 2} compatibility. As a result of the lack of pertinent compatibility data, it is readily apparent that detailed studies are required on CsCl and SrF{sub 2} compatibility and at least scouting studies must be made on the compatibility of the backup packaging compounds. This report summarizes the compatibility studies that are underway at PNL using non-radioactive compounds. Capsule fabrication procedures and tests schedules are outlined.

  3. Suitability of locally manufactured galvanized iron (GI wire fiber as reinforcing fiber in brick chip concrete

    Directory of Open Access Journals (Sweden)

    Md. Abul Bashar Emon

    2017-12-01

    Full Text Available A case study has been conducted in order to improve concrete quality in Bangladesh, using fiber reinforcing techniques with locally available low-cost Galvanized Iron (GI wire fibers. GI wire is in fact mild steel wire with a thin coating of zinc. In order to assess the suitability of GI wire fibers as an alternative to steel fibers, various properties of GI wire fibers i.e. tensile strength, bending capacity etc. have been investigated and compared with the properties of steel fibers in light of relevant ACI and ASTM guidelines. Various tests were conducted on GI wire fibers as well as plain concrete reinforced with GI wire fibers. The experimental results show that GI wire fiber has compatible properties with steel fibers. Moreover, compressive strength, flexural strength, toughness indices and residual strength factors of GI wire fiber reinforced concrete (GFRC have shown significant improvement compared to normal concrete. A comparison with Steel Fiber Reinforced Concrete (SFRC revealed that performance of GFRC is quite similar to that of SFRC. It was observed that fiber content of 2.5-3.5% by weight produces relatively better results for the particular mix design used in the study. Furthermore, a cost analysis reveals that SFRC is about 19% more expensive than GFRC in Bangladesh; for 1 cubic meter of concrete work when fiber dosage is 2.5% by weight. Therefore, the study finds that GFRC has shown some promising results to be a low-cost alternative to steel fiber reinforced concrete from Bangladesh’s perspective.

  4. Optical Fibers

    Science.gov (United States)

    Ghatak, Ajoy; Thyagarajan, K.

    With the development of extremely low-loss optical fibers and their application to communication systems, a revolution has taken fiber glass place during the last 40 years. In 2001, using glass fibers as the transmission medium and lightwaves as carrier wave waves, information was transmitted at a rate more than 1 Tbit/s (which is roughly equivalent to transmission of about 15 million simultaneous telephone conversations) through one hair thin optical fiber. Experimental demonstration of transmission at the rate of 14 Tbit/s over a 160 km long single fiber was demonstrated in 2006, which is equivalent to sending 140 digital high definition movies in 1 s. Very recently record transmission of more than 100 Tbit/s over 165 km single mode fiber has been reported. These can be considered as extremely important technological achievements. In this chapter we will discuss the propagation characteristics of optical fibers with special applications to optical communication systems and also present some of the noncommunication applications such as sensing.

  5. Vacuum fiber-fiber coupler

    Science.gov (United States)

    Heinrici, Axel; Bjelajac, Goran; Jonkers, Jeroen; Jakobs, Stefan; Olschok, Simon; Reisgen, Uwe

    2017-02-01

    Research and development carried out by the ISF Welding and Joining Institute of RWTH Aachen University has proven that combining high power laser and low vacuum atmosphere provides a welding performance and quality, which is comparable to electron beam welding. The developed welding machines are still using a beam forming which takes place outside the vacuum and the focusing laser beam has to be introduced to the vacuum via a suitable window. This inflexible design spoils much of the flexibility of modern laser welding. With the target to bring a compact, lightweight flying optics with flexible laser transport fibers into vacuum chambers, a high power fiber-fiber coupler has been adapted by II-VI HIGHYAG that includes a reliable vacuum interface. The vacuum-fiber-fiber coupler (V-FFC) is tested with up to 16 kW sustained laser power and the design is flexible in terms of a wide variety of laser fiber plug systems and vacuum flanges. All that is needed to implement the V-FFC towards an existing or planned vacuum chamber is an aperture of at least 100 mm (4 inch) diameter with any type of vacuum or pressure flange. The V-FFC has a state-of-the-art safety interface which allows for fast fiber breakage detection for both fibers (as supported by fibers) by electric wire breakage and short circuit detection. Moreover, the System also provides connectors for cooling and electric signals for the laser beam optics inside the vacuum. The V-FFC has all necessary adjustment options for coupling the laser radiation to the receiving fiber.

  6. Air-Guiding Photonic Bandgap Fibers: Spectral Properties, Macrobending Loss, and Practical Handling

    DEFF Research Database (Denmark)

    Hansen, Theis Peter; Broeng, Jes; Jakobsen, Christian

    2004-01-01

    For development of hollow-core transmission fibers, the realizable fibers lengths, bandwidth, characterization, and compatibility with standard technology are important issues. We report record-length air-guiding fiber, spectral properties, splicing, and optical time domain reflectometer (OTDR......) measurements. Furthermore, spectral macrobending loss measurements for two different designs of air-core photonic bandgap fibers are presented. While bending loss is observed, it does not limit operation for all practical bending diameters (>tex/tex...

  7. Pose Reconstruction of Flexible Instruments from Endoscopic Images using Markers

    NARCIS (Netherlands)

    Reilink, Rob; Stramigioli, Stefano; Misra, Sarthak

    2012-01-01

    A system is developed that can reconstruct the pose of flexible endoscopic instruments that are used in ad- vanced flexible endoscopes using solely the endoscopic images. Four markers are placed on the instrument, whose positions are measured in the image. These measurements are compared to a

  8. Post-endoscopic biliary sphincterotomy bleeding: an interventional radiology approach.

    LENUS (Irish Health Repository)

    Dunne, Ruth

    2013-12-01

    Endoscopic sphincterotomy is an integral component of endoscopic retrograde cholangiopancreatography. Post-sphincterotomy hemorrhage is a recognized complication. First line treatment involves a variety of endoscopic techniques performed at the time of sphincterotomy. If these are not successful, transcatheter arterial embolization or open surgical vessel ligation are therapeutic considerations.

  9. Transanal submucosal endoscopic resection (TASER) by TEO system®.

    Science.gov (United States)

    Muñoz de Nova, José Luis; Viamontes Ugalde, Francisco Eduardo; Mendoza Jiménez-Ridruejo, Jorge

    2016-07-01

    Given the higher incidence of non-invasive colorectal tumors due to the further implementation of screening techniques, multiple endoscopic techniques have emerged for its resection. Recently described, transanal submucosal endoscopic resection (TASER) pools the concepts of endoscopic resection with the transanal surgery. We report our initial experience and reflections on this new technique.

  10. To evaluate the results of endoscopic variceal band ligation (EVBL)

    African Journals Online (AJOL)

    hi-tech

    2004-04-04

    Apr 4, 2004 ... Lay, C.S. Tsai, Y.T. Teg, C.Y. et al. Endoscopic variceal ligation in prophylaxis of first variceal bleeding in cirrhotic patients with high-risk esophageal varices. Hepatology. 1997;. 25:346-350. 24. Stiegmann, G.V. Goff, J.S. Michaletz-Onody, P.A. et al. Endoscopic sclerotherapy as compared with endoscopic.

  11. Coccidioides immitis and Mycobacterium tuberculosis diagnosed by endoscopic ultrasound.

    Science.gov (United States)

    Naidu, Veena G; Tammineni, Anil K; Biscopink, Ronald J; Davis, Terry L; Veerabagu, Manjakkollai P

    2009-02-01

    The use of endoscopic ultrasound in staging non-small cell lung cancer is well known. Its role in diagnosing non-malignant conditions that cause mediastinal adenopathy is still not well established. We diagnosed Coccidioides immitis and Mycobacterium tuberculosis in two patients using endoscopic ultrasound. To our knowledge this is the first case of Coccidioidomycosis to be diagnosed by endoscopic ultrasound.

  12. [12 years of endoscopic stone removal].

    Science.gov (United States)

    Gysi, B; Schmassmann, A; Scheurer, U; Halter, F

    1993-05-29

    All 583 attempts at endoscopic clearance of biliary calculi, performed in the Gastrointestinal Unit, Inselspital Bern, were retrospectively analyzed from 1980 until 1991. The average age of the patients was 70; 56% were female and 44% male. In 1980, 26 ERCPs for bile duct stone removal were performed, whereas in 1991 the number had increased to 90. The substantial increase in 1991 occurred after introduction of laparoscopic cholecystectomy. Over the total period of 12 years all stones were removed endoscopically after papillotomy in 82%, while the success rate in 1991 was 90%. Morbidity was 5.4% and lethality 0.2%. Total morbidity did not change markedly. However, the number of severe complications requiring surgical repair was reduced from 1.7% between 1980 and 1986 to 0% between 1987 and 1991. These results suggest that endoscopic removal of bile duct stones is increasingly performed with high success and low complication rates.

  13. Endoscopic management of pancreatic pseudocysts and necrosis.

    Science.gov (United States)

    Law, Ryan; Baron, Todd H

    2015-02-01

    Over the last several years, there have been refinements in the understanding and nomenclature regarding the natural history of acute pancreatitis. Patients with acute pancreatitis frequently develop acute pancreatic collections that, over time, may evolve into pancreatic pseudocysts or walled-off necrosis. Endoscopic management of these local complications of acute pancreatitis continues to evolve. Treatment strategies range from simple drainage of liquefied contents to repeated direct endoscopic necrosectomy of a complex necrotic collection. In patients with chronic pancreatitis, pancreatic pseudocysts may arise as a consequence of pancreatic ductal obstruction that then leads to pancreatic ductal disruption. In this review, we focus on the indications, techniques and outcomes for endoscopic therapy of pancreatic pseudocysts and walled-off necrosis.

  14. Endoscopic anatomy of the pediatric middle ear.

    Science.gov (United States)

    Isaacson, Glenn

    2014-01-01

    Traditionally, otologists have aimed to produce a clean, dry, safe ear with the best possible hearing result. More recently, "less invasively" has been added to this list of goals. The development of small-diameter, high-quality rigid endoscopes and high-definition video systems has made totally endoscopic, transcanal surgery a reality in adult otology and a possibility in pediatric otology. This article reviews the anatomy of the pediatric middle ear and its surrounding airspaces and structures based on the work of dozens of researchers over the past 50 years. It will focus on the developmental changes in ear anatomy from birth through the first decade, when structure and function change most rapidly. Understanding the limits and possibilities afforded by new endoscopic technologies, the pediatric otologist can strive for results matching or exceeding those achieved by more invasive surgical approaches.

  15. Diagnosis and management of iatrogenic endoscopic perforations

    DEFF Research Database (Denmark)

    Paspatis, Gregorios A; Dumonceau, Jean-Marc; Barthet, Marc

    2014-01-01

    perforation, ESGE recommends that the endoscopist reports: its size and location with a picture; endoscopic treatment that might have been possible; whether carbon dioxide or air was used for insufflation; and the standard report information. 3 ESGE recommends that symptoms or signs suggestive of iatrogenic......This Position Paper is an official statement of the European Society of Gastrointestinal Endoscopy (ESGE). It addresses the diagnosis and management of iatrogenic perforation occurring during diagnostic or therapeutic digestive endoscopic procedures. Main recommendations 1 ESGE recommends that each...

  16. Endoscopic management of acute peptic ulcer bleeding.

    Science.gov (United States)

    Lu, Yidan; Chen, Yen-I; Barkun, Alan

    2014-12-01

    This review discusses the indications, technical aspects, and comparative effectiveness of the endoscopic treatment of upper gastrointestinal bleeding caused by peptic ulcer. Pre-endoscopic considerations, such as the use of prokinetics and timing of endoscopy, are reviewed. In addition, this article examines aspects of postendoscopic care such as the effectiveness, dosing, and duration of postendoscopic proton-pump inhibitors, Helicobacter pylori testing, and benefits of treatment in terms of preventing rebleeding; and the use of nonsteroidal anti-inflammatory drugs, antiplatelet agents, and oral anticoagulants, including direct thrombin and Xa inhibitors, following acute peptic ulcer bleeding. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Simultaneous fingerprint and high-wavenumber fiber-optic Raman endoscopy for in vivo diagnosis of laryngeal cancer

    Science.gov (United States)

    Lin, Kan; Zheng, Wei; Wang, Jianfeng; Lim, Chwee Ming; Huang, Zhiwei

    2016-02-01

    We report a unique simultaneous fingerprint (FP) and high-wavenumber (HW) fiber-optic confocal Raman spectroscopy for in vivo diagnosis of laryngeal cancer in the head and neck under wide-field endoscopic imaging. The simultaneous FP and HW Raman endoscopy technique was performed on 21 patients and differentiated laryngeal carcinoma from normal tissues with both sensitivity and specificity of ~85%. This study shows the great potential of the FP/HW Raman endoscopic technique developed for in vivo diagnosis of laryngeal carcinoma during routine endoscopic examination.

  18. Sensitivity improvement of optical fiber acoustic probe for all-optical photoacoustic imaging system

    Science.gov (United States)

    Seki, Atsushi; Iwai, Katsumasa; Katagiri, Takashi; Matsuura, Yuji

    2017-07-01

    An acoustic probe based on a Fabry-Perot interferometer composed of a polymer film attached to the end of an optical fiber was designed and fabricated for an endoscopic, all-optical photoacoustic imaging system. The finesse of the interferometer was improved by forming a half-mirror at the end of the fiber and a partial reflection mirror on the outer surface of the polymer film. A photoacoustic imaging system was constructed by combining the fiber-optic acoustic probe with a bundle of hollow optical fibers used for the excitation of the photoacoustic wave, and an image of blood capillaries in a fish ovarian membrane was successfully obtained.

  19. [A novel miniature robotic endoscope design for intestinal inspection].

    Science.gov (United States)

    Chi, Dong-xiang; Yan, Guo-zheng; Lin, Liang-ming

    2002-03-01

    This paper makes a comparison between the traditional endoscope system and the active robotic endoscope system, discusses the human intestine-working conditions of the robotic endoscope system in detail and its design requirements. An active robotic endoscope system based on earthworn-locomotion principles is proposed here and besides, its structure and locomotion mechanism are analyzed. A new method of human intestinal intervention is brought out and it can prevent the robotic endoscope guided by a cone-shaped guide pipe from being jammed or damaged.

  20. Dehiscence following successful endoscopic closure of gastric perforation during endoscopic submucosal dissection

    Science.gov (United States)

    Sekiguchi, Masau; Suzuki, Haruhisa; Oda, Ichiro; Yoshinaga, Shigetaka; Nonaka, Satoru; Saka, Makoto; Katai, Hitoshi; Taniguchi, Hirokazu; Kushima, Ryoji; Saito, Yutaka

    2012-01-01

    Gastric perforation is one of the most serious complications that can occur during endoscopic submucosal dissection (ESD). In terms of the treatment of such perforations, we previously reported that perforations immediately observed and successfully closed with endoclips during endoscopic resection could be managed conservatively. We now report the first case in our medical facility of a gastric perforation during ESD that was ineffectively treated conservatively even after successful endoscopic closure. In December 2006, we performed ESD on a recurrent early gastric cancer in an 81-year-old man with a medical history of laparotomy for cholelithiasis. A perforation occurred during ESD that was immediately observed and successfully closed with endoclips so that ESD could be continued resulting in an en-bloc resection. Intensive conservative management was conducted following ESD, however, an endoscopic examination five days after ESD revealed dehiscence of the perforation requiring an emergency laparotomy. PMID:22919258

  1. A New Irrigation System (Endosplash) for a Rigid Endoscope in Trans-sphenoidal Endoscopic Surgery.

    Science.gov (United States)

    Kuroda, Rintarou; Nakajima, Takeshi; Yamaguchi, Takashi; Watanabe, Eiju

    2016-07-15

    Obstruction of the visual field by blood is a major hindrance during endonasal endoscopic surgery, and a rapid and effective method for cleaning the lens is needed. We developed a new lens-cleaning system that does not employ a sheath or an irrigation-suction system. It is a 20-mm long cylinder with side holes that is attached to the barrel of the endoscope and is connected to a syringe containing saline. When the syringe is pressed, saline flows down to the tip along the barrel and washes the lens without requiring a sheath. We report the use of the system in six cases of endonasal endoscopic surgery. The lens was wiped significantly less often than during similar surgery performed without the use of this system. The Endosplash is simple and enables the surgeon to clean the lens with a single press of a syringe, thereby greatly enhancing the efficacy of endoscopic surgery.

  2. Ex vivo feasibility study of endoscopic intraductal laser ablation of the breast.

    Science.gov (United States)

    de Boorder, Tjeerd; Waaijer, Laurien; van Diest, Paul J; Witkamp, Arjen J

    2017-10-09

    To determine the feasibility and safety of breast endoscopic thulium laser ablation for treatment of intraductal neoplasia. Ductoscopy is a minimally invasive endoscopic approach of the milk ducts of the breast via the nipple. Besides diagnosis in women with pathologic nipple discharge (PND), it allows non-invasive removal of intraductal lesions with a stalk like papillomas. Removal, however, is often incomplete and flat lesions cannot be targeted. We therefore developed laser ductoscopy. Dosimetry of laser ductoscopy was assessed in thirteen mastectomy specimens, applying power settings of 1-5 W with 100-1000 ms pulsed exposure to a 375-μm outer diameter thulium fiber laser. Subsequently histology was obtained from the breast tissue that was treated with the Thulium laser. Endoscopic view was maintained during ductoscopic laser ablation at 1-3 W. Increasing power to 4-5 W caused impaired vision due to shrinkage of the main duct around the ductoscope tip. Histology revealed localized ablation of the duct wall. We show for the first time that laser ductoscopy is technically feasible. The Thulium laser enables a superficial intraductal ablation and is a useful tool for intraductal interventions. An in vivo prospective study is needed to further demonstrate its potential. Lasers Surg. Med. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  3. Design and validation of a near-infrared fluorescence endoscope for detection of early esophageal malignancy

    Science.gov (United States)

    Waterhouse, Dale J.; Joseph, James; Neves, André A.; di Pietro, Massimiliano; Brindle, Kevin M.; Fitzgerald, Rebecca C.; Bohndiek, Sarah E.

    2016-08-01

    Barrett's esophagus is a known precursor lesion to esophageal adenocarcinoma. In these patients, early detection of premalignant disease, known as dysplasia, allows curative minimally invasive endoscopic therapy, but is confounded by a lack of contrast in white light endoscopy. Imaging fluorescently labeled lectins applied topically to the tissue has the potential to more accurately delineate dysplasia, but tissue autofluorescence limits both sensitivity and contrast when operating in the visible region. To overcome this challenge, we synthesized near-infrared (NIR) fluorescent wheat germ agglutinin (WGA-IR800CW) and constructed a clinically translatable bimodal NIR and white light endoscope. Images of NIR and white light with a field of view of 63 deg and an image resolution of 182 μm are coregistered and the honeycomb artifact arising from the fiber bundle is removed. A minimum detectable concentration of 110 nM was determined using a dilution series of WGA-IR800CW. We demonstrated ex vivo that this system can distinguish between gastric and squamous tissue types in mouse stomachs (p=0.0005) and accurately detect WGA-IR800CW fluorescence in human esophageal resections (compared with a gold standard imaging system, rs>0.90). Based on these findings, future work will optimize the bimodal endoscopic system for clinical trials in Barrett's surveillance.

  4. Endoscopic repair of an abdominal intercostal hernia.

    Science.gov (United States)

    Bobbio, Antonio; Ampollini, Luca; Prinzi, Gabriele; Sarli, Leopoldo

    2008-10-01

    Abdominal viscera herniation through the chest wall is a rare condition. A case is presented of an abdominal intercostal hernia of the seventh right intercostal space; its pathogenesis and clinical features are described, and also the combined endoscopic and percutaneous surgical approach employed for its repair.

  5. Successful Endoscopic Therapy of Traumatic Bile Leaks

    Directory of Open Access Journals (Sweden)

    Matthew P. Spinn

    2013-02-01

    Full Text Available Traumatic bile leaks often result in high morbidity and prolonged hospital stay that requires multimodality management. Data on endoscopic management of traumatic bile leaks are scarce. Our study objective was to evaluate the efficacy of the endoscopic management of a traumatic bile leak. We performed a retrospective case review of patients who were referred for endoscopic retrograde cholangiopancreatography (ERCP after traumatic bile duct injury secondary to blunt (motor vehicle accident or penetrating (gunshot trauma for management of bile leaks at our tertiary academic referral center. Fourteen patients underwent ERCP for the management of a traumatic bile leak over a 5-year period. The etiology included blunt trauma from motor vehicle accident in 8 patients, motorcycle accident in 3 patients and penetrating injury from a gunshot wound in 3 patients. Liver injuries were grade III in 1 patient, grade IV in 10 patients, and grade V in 3 patients. All patients were treated by biliary stent placement, and the outcome was successful in 14 of 14 cases (100%. The mean duration of follow-up was 85.6 days (range 54-175 days. There were no ERCP-related complications. In our case review, endoscopic management with endobiliary stent placement was found to be successful and resulted in resolution of the bile leak in all 14 patients. Based on our study results, ERCP should be considered as first-line therapy in the management of traumatic bile leaks.

  6. ENDOSCOPIC TREATMENT OF CHYLURIA USING POVIDONE

    African Journals Online (AJOL)

    Solapur Kidney Care and Research Center, Maharashtra, India. Objectivez-To evaluate the safety and efficacy ... Conclusion: Povidone iodine is a very safe and efficacious agent for the endoscopic treatment of chyluria by ..... ment of tilarial chyluria in Japan. J Uroi 1983,. 129:64. 10. Chang CY, Lue YB, Lapides J. Surgical ...

  7. Ethical challenges of percutaneous endoscopic gastrostomy.

    Science.gov (United States)

    Morgenstern, L; Laquer, M; Treyzon, L

    2005-03-01

    Percutaneous endoscopic gastrostomy (PEG) is a widely used procedure for patients who cannot swallow. Although it is mostly performed for valid indications, its use in terminally ill patients is questionable. In this study, more than 30% of patients died in hospital after PEG placement and 16% died less than 30 days after placement. Strict guidelines and oversight or PEG placement are recommended.

  8. Endoscopic third ventriculostomy and choroid plexus cauterization ...

    African Journals Online (AJOL)

    Background: Endoscopic third ventriculostomy (ETV) and Choroid Plexus Cauterization (CPC) have been recommended as reliable surgical options in developing countries for childhood hydrocephalus owing to reported shunt failures in shunt dependency. Objective: To evaluate outcomes of the ETV and ETV-CPC ...

  9. Oesophageal cancer and experience with endoscopic stent ...

    African Journals Online (AJOL)

    Background: Oesophageal cancer often presents in advanced stages not amenable to surgical resection. In such patients, palliation of dysphagia remains the mainstay of management. Objectives: To determine the burden of advanced oesophageal cancer and to document the experience with endoscopic metal stent ...

  10. Esophageal Stricture Post Endoscopic Injection Sclerotherapy ...

    African Journals Online (AJOL)

    Background: Post endoscopic sclerotherapy esophageal stricture is usually not fatal but may requires several sessions of esophageal dilation as an effective palliative treatment yet has its own complications. Aim: The purpose of this study is to find out the predictors of sclerotherapy esophageal stricture. Methods: This is a ...

  11. Endoscopic management of bile leaks after laparoscopic ...

    African Journals Online (AJOL)

    Endoscopic intervention is widely accepted as the treatment of choice. This study assessed ... Seven patients had one or more complications related to the ERCP: 3 acute pancreatitis, 2 cholangitis, 2 sphincterotomy bleeds, 1 duodenal perforation and 1 impacted Dormia basket, the latter 2 requiring operative intervention.

  12. Real-time endoscopic optical properties imaging

    Science.gov (United States)

    Angelo, Joseph P.; van de Giessen, Martijn; Gioux, Sylvain

    2017-01-01

    With almost 50% of all surgeries in the U.S. being performed as minimally invasive procedures, there is a need to develop quantitative endoscopic imaging techniques to aid surgical guidance. Recent developments in widefield optical imaging make endoscopic implementations of real-time measurement possible. In this work, we introduce a proof-of-concept endoscopic implementation of a functional widefield imaging technique called 3D single snapshot of optical properties (3D-SSOP) that provides quantitative maps of absorption and reduced scattering optical properties as well as surface topography with simple instrumentation added to a commercial endoscope. The system’s precision and accuracy is validated using tissue-mimicking phantoms, showing a max error of 0.004 mm−1, 0.05 mm−1, and 1.1 mm for absorption, reduced scattering, and sample topography, respectively. This study further demonstrates video acquisition of a moving phantom and an in vivo sample with a framerate of approximately 11 frames per second. PMID:29188107

  13. An observational study on oesophageal variceal endoscopic ...

    African Journals Online (AJOL)

    African Journal of Health Sciences ... The study site was the Centre for Clinical Research, Kenya Medical Research Institute (KEMRI). ... All the patients with portal hypertension and previous history of acute variceal blood who underwent endoscopic injection sclerotherapy between August 1998 and May 2001 in the ...

  14. Current considerations of direct percutaneous endoscopic jejunostomy.

    Science.gov (United States)

    Zhu, Yanfei; Shi, Liping; Tang, Hao; Tao, Guoqing

    2012-02-01

    BACKGROUOND: Direct percutaneous endoscopic jejunostomy (DPEJ) is a well-known approach to deliver postpyloric enteral nutritional support to individuals who cannot tolerate gastric feeding. However, it is technically difficult, and some case series have reported significant procedural failure rates. The present article describes current indications, successes and complications of DPEJ placement. A MEDLINE database search was performed to identify relevant articles using the key words "direct percutaneous endoscopic jejunostomy", "percutaneous endoscopic gastrostomy", and "percutaneous endoscopic gastrostomy with a jejunal extension tube". Additional articles were identified by a manual search of the references cited in the key articles obtained in the primary search. DPEJ is gradually becoming more common in the treatment of patients who cannot tolerate gastric feeding. Differences in patient selection and technique modifications may contribute to the various success rates reported. Failure is most often due to inadequate transillumination or gastroduodenal obstruction. Currently, there are limited data to evaluate the safety and effectiveness of DPEJ. The clinical use of DPEJ is increasing. With appropriate care and expertise, DPEJ may prove to be reliable and safe.

  15. Current considerations in direct percutaneous endoscopic jejunostomy

    Science.gov (United States)

    Zhu, Yanfei; Shi, Liping; Tang, Hao; Tao, Guoqing

    2012-01-01

    BACKGROUND: Direct percutaneous endoscopic jejunostomy (DPEJ) is a well-known approach to deliver postpyloric enteral nutritional support to individuals who cannot tolerate gastric feeding. However, it is technically difficult, and some case series have reported significant procedural failure rates. The present article describes current indications, successes and complications of DPEJ placement METHODS: A MEDLINE database search was performed to identify relevant articles using the key words “direct percutaneous endoscopic jejunostomy”, “percutaneous endoscopic gastrostomy”, and “percutaneous endoscopic gastrostomy with a jejunal extension tube”. Additional articles were identified by a manual search of the references cited in the key articles obtained in the primary search. RESULTS: DPEJ is gradually becoming more common in the treatment of patients who cannot tolerate gastric feeding. Differences in patient selection and technique modifications may contribute to the various success rates reported. Failure is most often due to inadequate transillumination or gastroduodenal obstruction. Currently, there are limited data to evaluate the safety and effectiveness of DPEJ. CONCLUSION: The clinical use of DPEJ is increasing. With appropriate care and expertise, DPEJ may prove to be reliable and safe. PMID:22312608

  16. Shaft-Guidance for Flexible Endoscopes

    NARCIS (Netherlands)

    Loeve, A.J.

    2012-01-01

    Flexible endoscopes (long, slender, flexible instruments with a camera and light at the distal end, having working channels to introduce flexible instruments) are used for diagnostic and therapeutic interventions inside the human digestive system and inside the abdomen. Though used for their

  17. Endoscopic management of bile leaks after laparoscopic ...

    African Journals Online (AJOL)

    2013-11-04

    Nov 4, 2013 ... abscesses, interloop and intra-abdominal sepsis and cholangitis, or the later secondary sequelae of biliary cirrhosis, portal hypertension and end-stage liver disease. There is consensus that optimal management of a bile duct injury requires multidisciplinary. Endoscopic management of bile leaks after.

  18. [Extended endoscopic endonasal approach to skull base].

    Science.gov (United States)

    López-Arbolay, Omar; González-González, Justo; Rojas-Manresa, Jorge Luis

    2012-11-01

    Different approaches to the skull base have been developed through the sphenoidal sinus. Traditional boundaries of the trans-sphenoidal approach can be extended in antero-posterior and lateral plane. We review our experience with extended endoscopic endonasal approach in 127 cases. We used the extended endoscopic endonasal approach in 127 patients with different lesions of the skull base. This study specifically focuses on: type of lesions, surgical approach, outcome and surgical complications. Extended endoscopic endonasal approach was used in 127 patients with following lesions: 61 invasive adenomas to cavernous sinus, 10 clival chordomas, 21 craniopharyngiomas, 26 meningiomas, 4 cerebrospinal fluid leakages, one meningoencephalocele, 2 malignan lesions and 2 thyroid ophthalmopathy. In tumoral lesions gross total resection was achieved in 82.5%, with better results in craniopharyngiomas 90.5%, followed by invasive adenomas with 85.2%, and meningiomas with 84.6%. The most frequent complications were the insipid (8.6%) diabetes, meningoencefalitis (3.9%) and the hydrocephalic (3.9%). Mortality was 3.9%. The extended endoscopic endonasal approach is a promising minimally invasive alternative for selective cases with skull base lesions. As techniques and technology advance this approach may become the procedure of choice for most lesions and should be considered an option in the management of the patients with these complex pathologies by skull base surgeon. Copyright © 2012 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  19. Oesophageal cancer and experience with endoscopic stent ...

    African Journals Online (AJOL)

    Background: Oesophageal cancer often presents in advanced stages not amenable to surgical resection. In such patients, palliation of dysphagia remains the mainstay of management. oBjectives: To determine the burden of advanced oesophageal cancer and to document the experience with endoscopic metal stent.

  20. ENDOSCOPIC TREATMENT OF CARPAL TUNNEL SYNDROME

    Directory of Open Access Journals (Sweden)

    Samo K. Fokter

    2001-12-01

    Full Text Available Background. Carpal tunnel syndrome (CTS is a frequent cause of hand pain, numbness and paresthesias. Clinical outcome studies have been shown that endoscopic transverse carpal ligament release is an effective operation for treating idiopathic CTS. This retrospective study was designed to determine the one- to five-year outcome of endoscopic surgery for this disease.Methods. Single portal endoscopic carpal tunnel release (ECTR was performed on 68 hands in 48 patients who had clinical signs and symptoms consistent with CTS confirmed with electrodiagnostic studies. Charts were reviewed and the following data were obtained: age, duration of symptoms, time of hospitalization and complications. 57 cases (40 patients responded to a questionnaire and follow-up nerve conduction studies were available in 44 cases (65% of the entire cohort. The data of electrodiagnostic studies before treatment and at follow-up were statistically compared.Results. In two cases symptoms persisted and open surgery was performed two months after endoscopic procedure. Majority of hands (49 out of 57; 86% were pain-free at the final follow-up. Electrodiagnostic studies confirmed significant difference in nerve conduction latencies, action potentials (p < 0.01 and sensory conduction velocities (p < 0.05.Conclusions. ECTR offers safe decompression of the median nerve. The resumption of activities of daily living is short and many patients are allowed to return to work soon.

  1. Potential capacity of endoscopic screening for gastric cancer in Japan.

    Science.gov (United States)

    Hamashima, Chisato; Goto, Rei

    2017-01-01

    In 2016, the Japanese government decided to introduce endoscopic screening for gastric cancer as a national program. To provide endoscopic screening nationwide, we estimated the proportion of increase in the number of endoscopic examinations with the introduction of endoscopic screening, based on a national survey. The total number of endoscopic examinations has increased, particularly in clinics. Based on the national survey, the total number of participants in gastric cancer screening was 3 784 967. If 30% of the participants are switched from radiographic screening to endoscopic screening, approximately 1 million additional endoscopic examinations are needed. In Japan, the participation rates in gastric cancer screening and the number of hospitals and clinics offering upper gastrointestinal endoscopy vary among the 47 prefectures. If the participation rates are high and the numbers of hospitals and clinics are small, the proportion of increase becomes larger. Based on the same assumption, 50% of big cities can provide endoscopic screening with a 5% increase in the total number of endoscopic examinations. However, 16.7% of the medical districts are available for endoscopic screening within a 5% increase in the total number of endoscopic examinations. Despite the Japanese government's decision to introduce endoscopic screening for gastric cancer nationwide, its immediate introduction remains difficult because of insufficient medical resources in rural areas. This implies that endoscopic screening will be initially introduced to big cities. To promote endoscopic screening for gastric cancer nationwide, the disparity of medical resources must first be resolved. © 2016 The Authors. Cancer Science published by John Wiley & Sons Australia, Ltd on behalf of Japanese Cancer Association.

  2. Electromagnetic Compatibility for the Space Shuttle

    Science.gov (United States)

    Scully, Robert C.

    2004-01-01

    This slide presentation reviews the Space Shuttle electromagnetic compatibility (EMC). It includes an overview of the design of the shuttle with the areas that are of concern for the electromagnetic compatibility. It includes discussion of classical electromagnetic interference (EMI) and the work performed to control the electromagnetic interference. Another area of interest is electrostatic charging and the threat of electrostatic discharge and the attempts to reduce damage to the Shuttle from these possible hazards. The issue of electrical bonding is als reviewed. Lastly the presentation reviews the work performed to protect the shuttle from lightning, both in flight and on the ground.

  3. Compatible Spatial Discretizations for Partial Differential Equations

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, Douglas, N, ed.

    2004-11-25

    From May 11--15, 2004, the Institute for Mathematics and its Applications held a hot topics workshop on Compatible Spatial Discretizations for Partial Differential Equations. The numerical solution of partial differential equations (PDE) is a fundamental task in science and engineering. The goal of the workshop was to bring together a spectrum of scientists at the forefront of the research in the numerical solution of PDEs to discuss compatible spatial discretizations. We define compatible spatial discretizations as those that inherit or mimic fundamental properties of the PDE such as topology, conservation, symmetries, and positivity structures and maximum principles. A wide variety of discretization methods applied across a wide range of scientific and engineering applications have been designed to or found to inherit or mimic intrinsic spatial structure and reproduce fundamental properties of the solution of the continuous PDE model at the finite dimensional level. A profusion of such methods and concepts relevant to understanding them have been developed and explored: mixed finite element methods, mimetic finite differences, support operator methods, control volume methods, discrete differential forms, Whitney forms, conservative differencing, discrete Hodge operators, discrete Helmholtz decomposition, finite integration techniques, staggered grid and dual grid methods, etc. This workshop seeks to foster communication among the diverse groups of researchers designing, applying, and studying such methods as well as researchers involved in practical solution of large scale problems that may benefit from advancements in such discretizations; to help elucidate the relations between the different methods and concepts; and to generally advance our understanding in the area of compatible spatial discretization methods for PDE. Particular points of emphasis included: + Identification of intrinsic properties of PDE models that are critical for the fidelity of numerical

  4. Compatibility and testing of electronic components

    CERN Document Server

    Jowett, C E

    2013-01-01

    Compatibility and Testing of Electronic Components outlines the concepts of component part life according to thresholds of failure; the advantages that result from identifying such thresholds; their identification; and the various tests used in their detection. The book covers topics such as the interconnection of miniature passive components; the integrated circuit compatibility and its components; the semiconductor joining techniques; and the thin film hybrid approach in integrated circuits. Also covered are topics such as thick film resistors, conductors, and insulators; thin inlays for el

  5. Ultrahigh-resolution endoscopic optical coherence tomography for in vivo mouse colonoscopy

    Science.gov (United States)

    Tumlinson, Alexandre Rex

    In vivo monitoring of mouse models of colon cancer promises to reduce the cost of research by improving sacrifice timing and allowing serial studies that observe the progression of disease and drug efficacy in a relatively small set of animals. Optical coherence tomography (OCT) is an optical analog of ultrasound imaging, capable of minimally-invasive mapping of light scatter intensity up to 2 mm deep in tissue. In this work, factors limiting resolution in OCT were examined and devices were created and applied to mouse colon imaging that extended the state-of-the-art in endoscopic ultrahigh-resolution OCT. First, axial chromatic aberration of the objective optics acts as a spectral filter in the sample arm limiting the effective bandwidth of the system. An achromatized endoscope design was demonstrated that achieved axial resolution of 2.3 mum in tissue and 4.4 mum lateral spot diameter with 101 dB sensitivity when interfaced with a time domain OCT system utilizing a 10-femtosecond laser (Deltalambda=150 nm FWHM, lambdac=800 nm). Second, dispersion matching between the sample and reference arms presents the practical resolution limit to endoscopic implementations including a separate, fiber-based reference arm. A second endoscope incorporated the reference arm into the tip of the endoscope using a novel custom beamsplitter prism and achieved 2.4 mum axial resolution in tissue without adjustments for pathlength or dispersion matching when interfaced with a spectrometer-based frequency domain OCT system and a similar laser. Third, non-linear dispersion of the sample media with respect to wavelength causes distortion and broadening of the axial point spread function when data are sampled uniformly in optical frequency. An experiment was performed on high dispersion glass to demonstrate that dispersion artifact free imaging can be achieved without post process corrections if the samples are acquired at equal intervals of media index of refraction divided by vacuum

  6. Endoscopic suturing versus endoscopic clip closure of the mucosotomy during a per-oral endoscopic myotomy (POEM): a case-control study.

    Science.gov (United States)

    Pescarus, Radu; Shlomovitz, Eran; Sharata, Ahmed M; Cassera, Maria A; Reavis, Kevin M; Dunst, Christy M; Swanström, Lee L

    2016-05-01

    Obtaining an adequate mucosal closure is one of the crucial steps in per-oral endoscopic myotomy (POEM). Thus far, there have been no objective data comparing the various available closure techniques. This case-controlled study attempts to compare the application of endoscopic clips versus endoscopic suturing for mucosotomy closure during POEM cases. A retrospective review of our prospective POEM database was performed. All cases in which endoscopic suturing was used to close the mucosotomy were matched to cases in which standard endoclips were used. Overall complication rate, closure time and mucosal closure costs between the two groups were compared. Both techniques offer good clinical results with good mucosal closure and the absence of postoperative leak. Closure time was significantly shorter (p = 0.044) with endoscopic clips (16 ± 12 min) when compared to endoscopic suturing (33 ± 11 min). Overall, the total closure cost analysis showed a trend toward lower cost with clips (1502 ± 849 USD) versus endoscopic suturing (2521 ± 575 USD) without reaching statistical significance (p = 0.073). The use of endoscopic suturing seems to be a safe method for mucosal closure in POEM cases. Closure time is longer with suturing than conventional closure with clips, and there is a trend toward higher overall cost. Endoscopic suturing is likely most cost-effective for difficult cases where conventional closure methods fail.

  7. Total Endoscopic Approach in Glomus Tympanicum Surgery

    Directory of Open Access Journals (Sweden)

    Ahmad Daneshi

    2017-11-01

    Full Text Available Introduction: Glomus tympanicum (GT is a benign primary tumor of the middle ear. The evolution of endoscopic ear surgery has allowed for an alternative approach to managing this vascular tumor. The purpose of this study was to evaluate an endoscopic approach in GT surgery, and also to investigate its applicability and feasibility.   Materials and Methods: Prospectively, 13 class I and II patients, according to the Glasscock-Jackson glomus classification, were candidates for management via a transcanal endoscopic approach. Patients were categorized into three groups according to the location of the tumor in the middle ear. Group A consisted of patients with tumors located anteriorly while occupying the Eustachian tube. Group B were patients with tumors located on the promontory with entirely visible tumor borders. Patients in Group C had tumors that occupied the entire middle ear. Under specially designed flap elevation and hemostasis, the tumors were completely removed using an endoscopic technique.   Results: Based on the classification criteria, three patients fell into Group A (30%, six into Group B (46%, and three into Group C (23%. The principal chief complaint was pulsatile tinnitus that disappeared after surgery in most cases. Hearing status was mostly mixed hearing loss. No change was detected in bone conduction after surgery, but air conduction was improved in nine cases. No major complication or recurrence was observed over 30 months of follow up.   Conclusion: Improved exposure and access in the endoscopic transcanal approach to GT leads to safe, rapid, and reliable tumor removal, as well as allowing comfortable surgery for both the surgeon and most patients.

  8. Endoscopic sleeve gastroplasty: the learning curve.

    Science.gov (United States)

    Hill, Christine; El Zein, Mohamad; Agnihotri, Abhishek; Dunlap, Margo; Chang, Angela; Agrawal, Alison; Barola, Sindhu; Ngamruengphong, Saowanee; Chen, Yen-I; Kalloo, Anthony N; Khashab, Mouen A; Kumbhari, Vivek

    2017-09-01

    Endoscopic sleeve gastroplasty (ESG) is gaining traction as a minimally invasive bariatric treatment. Concern that the learning curve may be slow, even among those proficient in endoscopic suturing, is a barrier to widespread implementation of the procedure. Therefore, we aimed to define the learning curve for ESG in a single endoscopist experienced in endoscopic suturing who participated in a 1-day ESG training program.  Consecutive patients who underwent ESG between February 2016 and November 2016 were included. The performing endoscopist, who is proficient in endoscopic suturing for non-ESG procedures, participated in a 1-day ESG training session before offering ESG to patients. The outcome measurements were length of procedure (LOP) and number of plications per procedure. Nonlinear regression was used to determine the learning plateau and calculate the learning rate.  Twenty-one consecutive patients (8 males), with mean age 47.7 ± 11.2 years and mean body mass index 41.8 ± 8.5 kg/m 2 underwent ESG. LOP decreased significantly across consecutive procedures, with a learning plateau at 101.5 minutes and a learning rate of 7 cases ( P  = 0.04). The number of plications per procedure also decreased significantly across consecutive procedures, with a plateau at 8 sutures and a learning rate of 9 cases ( P  < 0.001). Further, the average time per plication decreased significantly with consecutive procedures, reaching a plateau at 9 procedures ( P  < 0.001).  Endoscopists experienced in endoscopic suturing are expected to achieve a reduction in LOP and number of plications per procedure in successive cases, with progress plateauing at 7 and 9 cases, respectively.

  9. Radiological findings after endoscopic incision of ureterocele

    Energy Technology Data Exchange (ETDEWEB)

    Cheon, Jung Eun; Kim, In One; Seok, Eul Hye; Cha, Joo Hee; Choi, Gook Myung; Kim, Woo Sun; Yeon, Kyung Mo; Kim, Kwang Myung; Choi, Hwang [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of); Cheon, Jung Eun [Chungmu General Hospital, Chungmu (Korea, Republic of); Seok, Eul Hye [Seran General Hospital, Seoul (Korea, Republic of); Cha, Joo Hee [Green General Hospital, Seoul(Korea, Republic of); Choi, Guk Myung [Halla General Hospital, Cheju (Korea, Republic of)

    2001-01-01

    Endoscopic incision of ureterocele is considered a simple and safe method for decompression of urinary tract obstruction above ureterocele. The purpose of this study was to evaluate the radiological findings after endoscopic incision of ureterocele. We retrospectively reviewed the radiological findings (ultrasonography (US), intravenous urography, and voiding cystourethrography(VCU)) in 16 patients with ureterocele who underwent endoscopic incision (mean age at surgery, 15 months; M:F 3:13; 18 ureteroceles). According to the postoperative results, treatment was classified as successful when medical treatment was still required, and second operation when additional surgical treatment was required. Postoperative US (n=10) showed that in all patients, urinary tract obstruction was relieved: the kidney parenchima was thicker and the ureterocele was smaller. Intravenous urography (n=8), demonstrated that in all patients, urinary tract obstruction and the excretory function of the kidney had improved. Postoperative VCU indicated that in 92% of patients (12 of 13), endoscopic incision of the ureterocele led to vesicoureteral reflux(VUR). Of these twelve, seven (58%) showed VUR of more than grade 3, while newly developed VUR was seen in five of eight patients (63%) who had preoperative VCU. Surgery was successful in four patients (25%), partially successful in three (19%), and a second operation-on account of recurrent urinary tract infection and VUR of more than grase 3 during the follow-up period-was required by nine (56%). Although endoscopic incision of a ureterocele is a useful way of relieving urinary tract obstruction, an ensuing complication may be VUR. Postoperative US and intravenous urography should be used to evaluate parenchymal change in the kidney and improvement of uronary tract obstructon, while to assess the extend of VUR during the follow-up period , postoperative VCU is required.

  10. Endoscopic Sleeve Gastroplasty: How I Do It?

    Science.gov (United States)

    Lopez-Nava, G; Galvão, M P; Bautista-Castaño, I; Jimenez-Baños, A; Fernandez-Corbelle, J P

    2015-08-01

    Primary endoscopic weight loss therapies are of interest for access, simplicity, and economy. The objective of this manuscript is to describe the endoscopic sleeve gastroplasty used in 50 patients. The goal of this procedure is to reduce the gastric lumen into a tubular configuration, with the greater curvature modified by a line of sutured plications. General anesthesia with endotracheal intubation is needed. An endoscopic suturing system requiring a specific double-channel endoscope delivers full-thickness sets of running sutures from the antrum to the fundus. Patients are admitted and observed, with discharge planned within 24 h. Post-procedure outpatient care includes diet instruction with intensive follow-up by a multidisciplinary team. Voluntary oral contrast and endoscopy studies are scheduled to assess the gastroplasty at 3, 6, and 12 months. The technique was applied in 50 patients (13 men) with an average body mass index (BMI) of 37.7 kg/m(2) (range 30-47) with 13 having reached 1 year. Procedure duration averaged 66 min during which six to eight sutures on average were placed. All patients were discharged in less than 24 h. There were no major intra-procedural, early, or delayed adverse events. Weight loss parameters were satisfactory, mean BMI changes from 37.7 ± 4.6 to 30.9 ± 5.1 kg/m(2) at 1 year, and mean %TBWL was 19.0 ± 10.8. Oral contrast studies and endoscopy revealed sleeve gastroplasty configuration at least until 1 year of follow-up. Endoscopic sleeve gastroplasty is a safe, effective, and reproducible primary weight loss technique.

  11. Electrospun fiber and cast films produced using zein blends with nylon-6

    Science.gov (United States)

    Blends of zein and nylon-6 (55k) were used to produce electrospun fibers and solution cast films. Zein was blended with nylon-6 in formic acid solution. When the amount of nylon-6 was 8% or less a compatible blend formed. The blend was determined to be compatible based on physical property measureme...

  12. 46 CFR 150.150 - Exceptions to the compatibility chart.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Exceptions to the compatibility chart. 150.150 Section... CARGOES COMPATIBILITY OF CARGOES § 150.150 Exceptions to the compatibility chart. The Commandant (G-MSO... 1, the Compatibility Chart. ...

  13. Ultrasonographic, endoscopic and histological appearances of the caecum in cats presenting with chronic clinical signs of caecocolic disease.

    Science.gov (United States)

    Hahn, Harriet; Pey, Pascaline; Baril, Aurélie; Charpentier, Julie; Desquilbet, Loic; Le Poder, Sophie; Château-Joubert, Sophie; Laloy, Eve; Freiche, Valerie

    2017-02-01

    Objectives This study aimed to describe the ultrasonographic, endoscopic and histological characteristics of the caecum and ileocaecocolic junction in cats suffering from chronic clinical signs compatible with caecocolic disease. Methods Cats presenting with clinical signs suggestive of a caecocolic disease were prospectively recruited. All cats underwent an ultrasonographic examination of the caecum, ileum, colon, ileocolic lymph nodes and local mesenteric fat, in addition to comprehensive abdominal ultrasonography. This was followed by a colonoscopy with a macroscopic assessment of the caecocolic mucosa; caecocolic tissue samples were systematically collected for histologic analysis. Results Eighteen cats were included. Eleven of 18 cats had ultrasonographic abnormalities adjacent to the ileocaecocolic junction (lymphadenopathy, local steatitis) and 13/18 cats had abnormalities directly related to the junction (wall thickening, loss of wall layering). Seventeen of 18 cats had at least one ultrasonographic abnormality. Endoscopically, hyperaemia, oedema, discoloration and/or erosions were found in all cats. Each cat was classified as having mild or moderate-to-severe lesions according to endoscopic results; no classification could be established statistically for ultrasonographic results. The accentuation of the dimpled pattern tended to be inversely related to the severity of endoscopic lesion scoring. Histologically, a large proportion of cats showed typhlitis (13/16), one had lymphoma and two were normal. All cats with typhlitis also had colitis. There was only slight agreement between endoscopic and histological caecal results regarding the severity of lesions. Loss of caecal wall layering on ultrasound was found in 7/18 cats and, surprisingly, did not appear as a reliable predictor of the severity of inflammation or of malignancy; neither did local steatitis nor lymph node size. Conclusions and relevance Ultrasonography and endoscopy should not be used as the

  14. Low-fiber diet

    Science.gov (United States)

    ... residue; Low-fiber diet; Fiber restricted diet; Crohn disease - low fiber diet; Ulcerative colitis - low fiber diet; ... pulp: Yellow squash (without seeds) Spinach Pumpkin Eggplant Potatoes, without skin Green beans Wax beans Asparagus Beets ...

  15. Soluble vs. insoluble fiber

    Science.gov (United States)

    Insoluble vs. soluble fiber; Fiber - soluble vs. insoluble ... There are 2 different types of fiber -- soluble and insoluble. Both are important for health, digestion, and preventing diseases. Soluble fiber attracts water and turns to gel during digestion. This slows ...

  16. Compatibility Between Electric Components in Wind Farms

    DEFF Research Database (Denmark)

    Holdyk, Andrzej; Holbøll, Joachim; Arana Aristi, Iván

    2011-01-01

    The paper describes a method for investigation of the compatibility between electric components in wind farms by identifying critical resonances at different points of an offshore wind farm (OWF), based on systematic variation of critical parameters. In this way, the design of future OWF can...

  17. Globalisation and international compatibility - a challenge to ...

    African Journals Online (AJOL)

    The contexts of institutions for higher education are in flux with consequent learning challenges. One of these challenges is that of globalisation and the need for international compatibility. Another challenge is that Mode 2 learning programmes, material and methods need to be relevant to the specific context in which they ...

  18. Screening for attractants compatible with entomopathogenic fungus ...

    African Journals Online (AJOL)

    Several thrips attractants were screened for compatibility with Metarhizium anisopliae (Metchnikoff) Sorokin (Hypocreales: Clavicipitaceae) and a subset of these for attraction to Megalurothrips sjostedti Trybom (Thysanoptera: Thripidae). Conidial germination and germ tube length of M. anisopliae were used as indicators of ...

  19. Electromagnetic compatibility design guideline for STADAN

    Science.gov (United States)

    Cowdell, R. B.; Hill, J. S.; Senn, J. C.; Shifman, J. C.; Skaggs, J. W.

    1971-01-01

    Procedures for achieving electromagnetic compatibility in electronic and electrical equipment for aerospace ground stations are investigated. The application of shielding theory to good design is treated and standards of good practice are outlined for bonding, grounding, wiring, and cabling. Some aspects of filter design are explained, and suggestions are given for the application of filters to electronic and electrical equipment.

  20. Plasmonic Modulator Using CMOS Compatible Material Platform

    DEFF Research Database (Denmark)

    Babicheva, Viktoriia; Kinsey, Nathaniel; Naik, Gururaj V.

    2014-01-01

    In this work, a design of ultra-compact plasmonic modulator is proposed and numerically analyzed. The device l ayout utilizes alternative plas monic materials such as tr ansparent conducting oxides and titanium nitride which potentially can be applied for CMOS compatible process. The modulation...

  1. Energetic materials standards – Chemical compatibility

    NARCIS (Netherlands)

    Tuukkanen, I.M.; Bouma, R.H.B.

    2014-01-01

    Subgroup A Energetic Materials Team, SG/A (EMT), develops and maintains standards that are relevant to all life-cycle phases of ammunition/weapon systems. STANAG 4147 is the standard regarding chemical compatibility of explosives with munition components, and is a document of prime importance.

  2. Compatibility of Motion Facilitates Visuomotor Synchronization

    Science.gov (United States)

    Hove, Michael J.; Spivey, Michael J.; Krumhansl, Carol L.

    2010-01-01

    Prior research indicates that synchronized tapping performance is very poor with flashing visual stimuli compared with auditory stimuli. Three finger-tapping experiments compared flashing visual metronomes with visual metronomes containing a spatial component, either compatible, incompatible, or orthogonal to the tapping action. In Experiment 1,…

  3. Catholic Educator Perceptions about Brain Compatible Instruction

    Science.gov (United States)

    Koenen, Amie

    2009-01-01

    This document reports the findings of a doctoral project regarding the perceptions held by administrators and teachers of comprehensive Catholic schools in one Midwestern diocese. With the recent explosion of research in the area of the brain and brain compatible instruction it is valuable to know and understand the perceptions held by current…

  4. Improvement of crash compatibility between cars

    NARCIS (Netherlands)

    Huibers, J.A.H.M.; Faerber, E.; Cesari, D.; Hobbs, A.C.; Kampen, B. van; Paez, J.; Wykes, N.J.

    1998-01-01

    This paper will provide an overview of the research work of the European Enhanced Vehicle-safety Committee (EEVC) in the field of crash compatibility between passenger cars. Since July 1997 the EC Commission is partly funding the research work of EEVC. The running period of this project will be two

  5. Improvement of crash compatibility between cars.

    NARCIS (Netherlands)

    Faerber, E. Cesari, D. Hobbs, A.C. Huibers, J. Kampen, B. van Paez, J. & Wykes, N.J.

    1999-01-01

    This paper provides an overview of the research work of the European Enhanced Vehicle-safety Committee (EEVC) in the field of crash compatibility between passenger cars. Since July 1997 the EC Commission is partly funding the research work of EEVC. The running period of this project will be two

  6. Are Naturalism and Moral Realism Compatible?

    NARCIS (Netherlands)

    Peels, H.D.

    2014-01-01

    In a recent paper, Alvin Plantinga has argued that there is good reason to think that naturalism and moral realism are incompatible. He has done so by arguing that the most important argument for the compatibility of these two theses, which has been provided by Frank Jackson, fails and that any

  7. The Construal (In)compatibility Effect

    DEFF Research Database (Denmark)

    Yang, Xiaojing; Ringberg, Torsten; Mao, Huifang

    2011-01-01

    incompatible with their mental construal, while ad claims construed at a level compatible with consumers' mental construal are more effective for those who possess a less creative mindset. We document that such differences in persuasion are driven by the fact that consumers with a creative (less creative) mind...

  8. Compatibility of Calamus deerratus and Lacosperma secundiflorum ...

    African Journals Online (AJOL)

    An investigation was conducted to determine the optimum water to cement ratio for a locally manufactured Portland cement for use in wood composites. The effects of pre-processing and calcium chloride (CaCl2) on the compatibility of two rattan canes (Calamus deerratus and Lacosperma secundiflorum) with cement were ...

  9. Design of wormlike automated robotic endoscope: dynamic interaction between endoscopic balloon and surrounding tissues.

    Science.gov (United States)

    Poon, Carmen C Y; Leung, Billy; Chan, Cecilia K W; Lau, James Y W; Chiu, Philip W Y

    2016-02-01

    The current design of capsule endoscope is limited by the inability to control the motion within gastrointestinal tract. The rising incidence of gastrointestinal cancers urged improvement in the method of screening endoscopy. This preclinical study aimed to design and develop a novel locomotive module for capsule endoscope. We investigated the feasibility and physical properties of this newly designed caterpillar-like capsule endoscope with a view to enhancing screening endoscopy. This study consisted of preclinical design and experimental testing on the feasibility of automated locomotion for a prototype caterpillar endoscope. The movement was examined first in the PVC tube and then in porcine intestine. The image captured was transmitted to handheld device to confirm the control of movement. The balloon pressure and volume as well as the contact force between the balloon and surroundings were measured when the balloon was inflated inside (1) a hard PVC tube, (2) a soft PVC tube, (3) muscular sites of porcine colons and (4) less muscular sites of porcine colons. The prototype caterpillar endoscope was able to move inward and backward within the PVC tubing and porcine intestine. Images were able to be captured from the capsule endoscope attached and being observed with a handheld device. Using the onset of a contact force as indication of the buildup of the gripping force between the balloon and the lumen walls, it is concluded from the results of this study that the rate of change in balloon pressure and volume is two good estimators to optimize the inflation of the balloon. The results of this study will facilitate further refinement in the design of caterpillar robotic endoscope to move inside the GI tract.

  10. fMRI-compatible rehabilitation hand device

    Directory of Open Access Journals (Sweden)

    Tzika Aria

    2006-10-01

    Full Text Available Abstract Background Functional magnetic resonance imaging (fMRI has been widely used in studying human brain functions and neurorehabilitation. In order to develop complex and well-controlled fMRI paradigms, interfaces that can precisely control and measure output force and kinematics of the movements in human subjects are needed. Optimized state-of-the-art fMRI methods, combined with magnetic resonance (MR compatible robotic devices for rehabilitation, can assist therapists to quantify, monitor, and improve physical rehabilitation. To achieve this goal, robotic or mechatronic devices with actuators and sensors need to be introduced into an MR environment. The common standard mechanical parts can not be used in MR environment and MR compatibility has been a tough hurdle for device developers. Methods This paper presents the design, fabrication and preliminary testing of a novel, one degree of freedom, MR compatible, computer controlled, variable resistance hand device that may be used in brain MR imaging during hand grip rehabilitation. We named the device MR_CHIROD (Magnetic Resonance Compatible Smart Hand Interfaced Rehabilitation Device. A novel feature of the device is the use of Electro-Rheological Fluids (ERFs to achieve tunable and controllable resistive force generation. ERFs are fluids that experience dramatic changes in rheological properties, such as viscosity or yield stress, in the presence of an electric field. The device consists of four major subsystems: a an ERF based resistive element; b a gearbox; c two handles and d two sensors, one optical encoder and one force sensor, to measure the patient induced motion and force. The smart hand device is designed to resist up to 50% of the maximum level of gripping force of a human hand and be controlled in real time. Results Laboratory tests of the device indicate that it was able to meet its design objective to resist up to approximately 50% of the maximum handgrip force. The detailed

  11. fMRI-compatible rehabilitation hand device.

    Science.gov (United States)

    Khanicheh, Azadeh; Muto, Andrew; Triantafyllou, Christina; Weinberg, Brian; Astrakas, Loukas; Tzika, Aria; Mavroidis, Constantinos

    2006-10-06

    Functional magnetic resonance imaging (fMRI) has been widely used in studying human brain functions and neurorehabilitation. In order to develop complex and well-controlled fMRI paradigms, interfaces that can precisely control and measure output force and kinematics of the movements in human subjects are needed. Optimized state-of-the-art fMRI methods, combined with magnetic resonance (MR) compatible robotic devices for rehabilitation, can assist therapists to quantify, monitor, and improve physical rehabilitation. To achieve this goal, robotic or mechatronic devices with actuators and sensors need to be introduced into an MR environment. The common standard mechanical parts can not be used in MR environment and MR compatibility has been a tough hurdle for device developers. This paper presents the design, fabrication and preliminary testing of a novel, one degree of freedom, MR compatible, computer controlled, variable resistance hand device that may be used in brain MR imaging during hand grip rehabilitation. We named the device MR_CHIROD (Magnetic Resonance Compatible Smart Hand Interfaced Rehabilitation Device). A novel feature of the device is the use of Electro-Rheological Fluids (ERFs) to achieve tunable and controllable resistive force generation. ERFs are fluids that experience dramatic changes in rheological properties, such as viscosity or yield stress, in the presence of an electric field. The device consists of four major subsystems: a) an ERF based resistive element; b) a gearbox; c) two handles and d) two sensors, one optical encoder and one force sensor, to measure the patient induced motion and force. The smart hand device is designed to resist up to 50% of the maximum level of gripping force of a human hand and be controlled in real time. Laboratory tests of the device indicate that it was able to meet its design objective to resist up to approximately 50% of the maximum handgrip force. The detailed compatibility tests demonstrated that there is

  12. Endoscopic management of upper urinary tract urothelial carcinoma.

    Science.gov (United States)

    Park, Bong Hee; Jeon, Seong Soo

    2013-07-01

    Upper urinary tract urothelial carcinoma (UTUC) is relatively uncommon. Radical nephroureterectomy with an ipsilateral bladder cuff excision has been the gold standard treatment for UTUC. However, recent advances in technology have made possible the increased use of endoscopic management for the treatment of UTUC. The definitive goal of endoscopic management of UTUC is cancer control while maintaining renal function and the integrity of the urinary tract. Endoscopic management includes both the retrograde ureteroscopic and antegrade percutaneous approaches. The endoscopic management of UTUC is a reasonable alternative for patients with renal insufficiency or a solitary functional kidney, bilateral disease, or a significant comorbidity that precludes radical surgery. Select patients with a functional contralateral kidney who have low-grade, low-stage tumors may also be candidates for endoscopic management. The careful selection of patients is the most important point for the successful endoscopic management of UTUC. It is crucial that patients are compliant and motivated, because a lifetime protocol of strict surveillance is necessary. Adjuvant topical therapy with Bacillus Calmette-Guerin or mitomycin C can be used after endoscopic management of UTUC in an attempt to reduce recurrence. In this article, we review current endoscopic techniques, indications for endoscopic treatment, clinical outcomes of endoscopic management, adjuvant topical therapy, and surveillance in patients with UTUC.

  13. Real-time resilient focusing through a bending multimode fiber.

    Science.gov (United States)

    Caravaca-Aguirre, Antonio M; Niv, Eyal; Conkey, Donald B; Piestun, Rafael

    2013-05-20

    Multimode optical fibers are attractive for biomedical and sensing applications because they possess a small cross section and can bend over small radii of curvature. However, mode phase-velocity dispersion and random mode coupling change with bending, temperature, and other perturbations, producing scrambling interference among propagating modes; hence preventing its use for focusing or imaging. To tackle this problem we introduce a system capable of re-focusing light through a multimode fiber in 37ms, one order of magnitude faster than demonstrated in previous reports. As a result, the focus spot can be maintained during significant bending of the fiber, opening numerous opportunities for endoscopic imaging and energy delivery applications. We measure the transmission matrix of the fiber by projecting binary-amplitude computer generated holograms using a digital micro-mirror device controlled by a field programmable gate array. The system shows two orders of magnitude enhancements of the focus spot relative to the background.

  14. Fiber resources

    Science.gov (United States)

    P. J. Ince

    2004-01-01

    In economics, primary inputs or factors of production define the term ‘resources.’ Resources include land resources (plants, animals, and minerals), labor, capital, and entrepreneurship. Almost all pulp and paper fiber resources are plant materials obtained from trees or agricultural crops. These resources encompass plant materials harvested directly from the land (...

  15. endoscope-i: an innovation in mobile endoscopic technology transforming the delivery of patient care in otolaryngology.

    Science.gov (United States)

    Mistry, N; Coulson, C; George, A

    2017-11-01

    Digital and mobile device technology in healthcare is a growing market. The introduction of the endoscope-i, the world's first endoscopic mobile imaging system, allows the acquisition of high definition images of the ear, nose and throat (ENT). The system combines the e-i Pro camera app with a bespoke engineered endoscope-i adaptor which fits securely onto the iPhone or iPod touch. Endoscopic examination forms a salient aspect of the ENT work-up. The endoscope-i therefore provides a mobile and compact alternative to the existing bulky endoscopic systems currently in use which often restrict the clinician to the clinic setting. Areas covered: This article gives a detailed overview of the endoscope-i system together with its applications. A review and comparison of alternative devices on the market offering smartphone adapted endoscopic viewing systems is also presented. Expert commentary: The endoscope-i fulfils unmet needs by providing a compact, highly portable, simple to use endoscopic viewing system which is cost-effective and which makes use of smartphone technology most clinicians have in their pocket. The system allows real-time feedback to the patient and has the potential to transform the way that healthcare is delivered in ENT as well as having applications further afield.

  16. Endoscope-assisted facelift thyroid surgery: an initial experience using a new endoscopic technique.

    Science.gov (United States)

    Park, Jun-Ook; Kim, Sang-Yeon; Chun, Byung-Joon; Joo, Young-Hoon; Cho, Kwang-Jae; Park, Young Hak; Kim, Min-Sik; Sun, Dong-Il

    2015-06-01

    A new approach to modifying facelift incision was recently developed for robotic thyroid surgery that seemed to be advantageous over other existing approaches. In this study, we aimed to investigate the feasibility and safety of the facelift approach not only for robotic thyroid surgery, but also for endoscope-assisted thyroid surgery. Endoscope-assisted facelift thyroid lobectomy was performed for 11 patients with papillary microcarcinoma. All 11 operations were successfully performed endoscopically. This approach through a modified facelift incision provided safe dissection of the laryngeal nerves and exposed an adequate working space. We identified and preserved all neighboring critical structures (parathyroid gland and superior and recurrent laryngeal nerves) during surgery. The operative duration for simple thyroid lobectomy with central lymph node dissection in 11 patients was 120-180 min (average duration: 140 min). Sensory change around the earlobe occurred in three patients and was recovered within 2 months after surgery in all patients. No patient displayed laryngeal nerve palsy or a low-pitched voice. The facelift approach seems to provide a shorter and more direct route to the thyroid, requiring minimal dissection, and an adequate workspace not only for robotic surgery but also for endoscopic surgery. It is worthwhile to develop and refine the surgical techniques of endoscopic facelift thyroid surgery.

  17. Effects of Fiber Reinforcement on Clay Aerogel Composites

    Directory of Open Access Journals (Sweden)

    Katherine A. Finlay

    2015-08-01

    Full Text Available Novel, low density structures which combine biologically-based fibers with clay aerogels are produced in an environmentally benign manner using water as solvent, and no additional processing chemicals. Three different reinforcing fibers, silk, soy silk, and hemp, are evaluated in combination with poly(vinyl alcohol matrix polymer combined with montmorillonite clay. The mechanical properties of the aerogels are demonstrated to increase with reinforcing fiber length, in each case limited by a critical fiber length, beyond which mechanical properties decline due to maldistribution of filler, and disruption of the aerogel structure. Rather than the classical model for reinforced composite properties, the chemical compatibility of reinforcing fibers with the polymer/clay matrix dominated mechanical performance, along with the tendencies of the fibers to kink under compression.

  18. Drawing optical fibers from three-dimensional printers.

    Science.gov (United States)

    Canning, John; Hossain, Md Arafat; Han, Chunyang; Chartier, Loic; Cook, Kevin; Athanaze, Tristan

    2016-12-01

    The temperature distribution within extrusion nozzles of three low-cost desktop 3D printers is characterized using fiber Bragg gratings (FBGs) to assess their compatibility as micro-furnaces for optical fiber and taper production. These profiles show remarkably consistent distributions suitable for direct drawing of optical fiber. As proof of principle, coreless optical fibers (φ=30  μm) made from fluorinated acrylonitrile butadiene styrene (ABS) and polyethylene terephthalate glycol (PETG) are drawn. Cutback measurements demonstrate propagation losses as low as α=0.26  dB/cm, which are comparable with standard optical fiber losses with some room for improvement. This work points toward direct optical fiber manufacture of any material from 3D printers.

  19. Effects of Fiber Reinforcement on Clay Aerogel Composites

    Science.gov (United States)

    Finlay, Katherine A.; Gawryla, Matthew D.; Schiraldi, David A.

    2015-01-01

    Novel, low density structures which combine biologically-based fibers with clay aerogels are produced in an environmentally benign manner using water as solvent, and no additional processing chemicals. Three different reinforcing fibers, silk, soy silk, and hemp, are evaluated in combination with poly(vinyl alcohol) matrix polymer combined with montmorillonite clay. The mechanical properties of the aerogels are demonstrated to increase with reinforcing fiber length, in each case limited by a critical fiber length, beyond which mechanical properties decline due to maldistribution of filler, and disruption of the aerogel structure. Rather than the classical model for reinforced composite properties, the chemical compatibility of reinforcing fibers with the polymer/clay matrix dominated mechanical performance, along with the tendencies of the fibers to kink under compression. PMID:28793515

  20. Fundus imaging with a nasal endoscope

    Directory of Open Access Journals (Sweden)

    P Mahesh Shanmugam

    2015-01-01

    Full Text Available Wide field fundus imaging is needed to diagnose, treat, and follow-up patients with retinal pathology. This is more applicable for pediatric patients as repeated evaluation is a challenge. The presently available imaging machines though provide high definition images, but carry the obvious disadvantages of either being costly or bulky or sometimes both, which limits its usage only to large centers. We hereby report a technique of fundus imaging using a nasal endoscope coupled with viscoelastic. A regular nasal endoscope with viscoelastic coupling was placed on the cornea to image the fundus of infants under general anesthesia. Wide angle fundus images of various fundus pathologies in infants could be obtained easily with readily available instruments and without the much financial investment for the institutes.

  1. Portal biliopathy treated with endoscopic biliary stenting

    Directory of Open Access Journals (Sweden)

    Sung Jin Jeon

    2016-03-01

    Full Text Available Portal biliopathy is defined as abnormalities in the extra- and intrahepatic ducts and gallbladder of patients with portal hypertension. This condition is associated with extrahepatic venous obstruction and dilatation of the venous plexus of the common bile duct, resulting in mural irregularities and compression of the biliary tree. Most patients with portal biliopathy remain asymptomatic, but approximately 10% of them advance to symptomatic abdominal pain, jaundice, and fever. Magnetic resonance cholangiopancreatography and endoscopic retrograde cholangiopancreatography are currently used as diagnostic tools because they are noninvasive and can be used to assess the regularity, length, and degree of bile duct narrowing. Management of portal biliopathy is aimed at biliary decompression and reducing the portal pressure. Portal biliopathy has rarely been reported in Korea. We present a symptomatic case of portal biliopathy that was complicated by cholangitis and successfully treated with biliary endoscopic procedures.

  2. Portal biliopathy treated with endoscopic biliary stenting.

    Science.gov (United States)

    Jeon, Sung Jin; Min, Jae Ki; Kwon, So Young; Kim, Jun Hyun; Moon, Sun Young; Lee, Kang Hoon; Kim, Jeong Han; Choe, Won Hyeok; Cheon, Young Koog; Kim, Tae Hyung; Park, Hee Sun

    2016-03-01

    Portal biliopathy is defined as abnormalities in the extra- and intrahepatic ducts and gallbladder of patients with portal hypertension. This condition is associated with extrahepatic venous obstruction and dilatation of the venous plexus of the common bile duct, resulting in mural irregularities and compression of the biliary tree. Most patients with portal biliopathy remain asymptomatic, but approximately 10% of them advance to symptomatic abdominal pain, jaundice, and fever. Magnetic resonance cholangiopancreatography and endoscopic retrograde cholangiopancreatography are currently used as diagnostic tools because they are noninvasive and can be used to assess the regularity, length, and degree of bile duct narrowing. Management of portal biliopathy is aimed at biliary decompression and reducing the portal pressure. Portal biliopathy has rarely been reported in Korea. We present a symptomatic case of portal biliopathy that was complicated by cholangitis and successfully treated with biliary endoscopic procedures.

  3. Endoscopic release of the cubital tunnel.

    Science.gov (United States)

    Zajonc, Horst; Momeni, Arash

    2014-02-01

    It is safe to say that in situ decompression of the ulnar nerve in cubital tunnel syndrome has been demonstrated to achieve equivalent functional results when compared with more elaborate techniques, such as decompression with nerve transposition. The evolution toward procedures associated with less patient morbidity is reflected by the introduction of endoscopic techniques for the treatment of cubital tunnel syndrome. The authors have incorporated the endoscopic approach as proposed by Hoffmann and Siemionow into their practice and have obtained favorable results. Although the skin incision can frequently be kept to a minimum (<2 cm), superior visualization associated with this approach allows for in situ decompression of the ulnar nerve along a distance of up to 30 cm. Despite the extent of decompression performed, operative morbidity is minimal, with return to full duty being the rule even in manual laborers within 10 to 14 days postoperatively. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Percutaneus Endoscopic Gastrostomy in Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Demet Tok

    2006-01-01

    Full Text Available Since its introduction in the early 1980s, percutaneous endoscopic gastrostomy (PEG technique has been used to create a reliable route for long term enteral feeding in cri0,0tically ill patients. Our goals were to determine the complications of PEG in ICU patients.We evaluated the data of 13 intensive care unit patients undergoing bedside PEG for gastric tube placement using the “pull” technique. Percutaneous endoscopic gastrostomy was completed and gastric tube was placed successfully in all patients. Tubes remained in stomach from 13 to 831 days (mean 146 days. Six patients died because of the reasons unrelated to the PEG tube and seven patients were discharged from the hospital while being fed via the PEG. Nutritional intolerance (in 4 patients and bleeding (in 3 patients were observed and could be eradicated by appropriate maintenance. Bleeding was the main PEG complication observed in critically ill patients.

  5. Comprehensive review on endonasal endoscopic sinus surgery

    Science.gov (United States)

    Weber, Rainer K.; Hosemann, Werner

    2015-01-01

    Endonasal endoscopic sinus surgery is the standard procedure for surgery of most paranasal sinus diseases. Appropriate frame conditions provided, the respective procedures are safe and successful. These prerequisites encompass appropriate technical equipment, anatomical oriented surgical technique, proper patient selection, and individually adapted extent of surgery. The range of endonasal sinus operations has dramatically increased during the last 20 years and reaches from partial uncinectomy to pansinus surgery with extended surgery of the frontal (Draf type III), maxillary (grade 3–4, medial maxillectomy, prelacrimal approach) and sphenoid sinus. In addition there are operations outside and beyond the paranasal sinuses. The development of surgical technique is still constantly evolving. This article gives a comprehensive review on the most recent state of the art in endoscopic sinus surgery according to the literature with the following aspects: principles and fundamentals, surgical techniques, indications, outcome, postoperative care, nasal packing and stents, technical equipment. PMID:26770282

  6. [Endoscopic ureterolithotripsy with the holmium laser].

    Science.gov (United States)

    Lopatkin, N A; Mazo, E B; Chepurov, A K; Dondukov, Ts V; Safarov, R M; Dreval', A A

    1997-01-01

    One of the clinical and experimental investigations performed in the urological clinic of the Moscow Medical University and Research Institute of Urology aimed at elucidation of Ho-YAG-laser potential in endoscopic lithotripsy (EL). Russian Ho-YAG laser surgical units CTH-10 and LLT-3 with wave length 2.09 mu were employed. The studies showed that the developed laser units satisfied relevant medical and technical requirements. Low depth of laser impulse penetration (0.4 mm) obtained at EL warrants safety of the adjacent tissues which is essential in crushing fixed ureteroliths in the presence of severe inflammation in the ureteral wall. The conclusion is made that Ho-YAG laser EL is an effective treatment of ureteroliths. Further tests for EL efficacy in affections of the upper urinary tracts are advocated to define a proper place of EL in endoscopic urology.

  7. Current Considerations in Direct Percutaneous Endoscopic Jejunostomy

    Directory of Open Access Journals (Sweden)

    Yanfei Zhu

    2012-01-01

    Full Text Available For patients who are unable to meet their nutritional needs orally, enteral feeding via a percutaneous approach has become the mainstay of therapy. However, traditional enteral feeding methods, such as percutaneous endoscopic gastrostomy, may not be viable options for patients with severe gastroparesis or gastric outlet obstruction. Direct percutaneous endoscopic jejunostomy (DPEJ is an enteral access method that was first described more than 20 years ago and has gained popularity among gastroenterologists. This review discusses the indications for and contraindications to DPEJ, the procedure, the application of DPEJ in specific subsets of patients with gastrointestinal disorders, and presents a brief tabular summary of complications and success rates of DPEJ in case series published since 2000.

  8. Current endoscopic approach to indeterminate biliary strictures

    Science.gov (United States)

    Victor, David W; Sherman, Stuart; Karakan, Tarkan; Khashab, Mouen A

    2012-01-01

    Biliary strictures are considered indeterminate when basic work-up, including transabdominal imaging and endoscopic retrograde cholangiopancreatography with routine cytologic brushing, are non-diagnostic. Indeterminate biliary strictures can easily be mischaracterized which may dramatically affect patient’s outcome. Early and accurate diagnosis of malignancy impacts not only a patient’s candidacy for surgery, but also potential timely targeted chemotherapies. A significant portion of patients with indeterminate biliary strictures have benign disease and accurate diagnosis is, thus, paramount to avoid unnecessary surgery. Current sampling strategies have suboptimal accuracy for the diagnosis of malignancy. Emerging data on other diagnostic modalities, such as ancillary cytology techniques, single operator cholangioscopy, and endoscopic ultrasonography-guided fine needle aspiration, revealed promising results with much improved sensitivity. PMID:23180939

  9. Endoscopic treatment of vesicoureteral reflux in pediatric patients

    Directory of Open Access Journals (Sweden)

    Jong Wook Kim

    2013-04-01

    Full Text Available Endoscopic treatment is a minimally invasive treatment for managing patients with vesicoureteral reflux (VUR. Although several bulking agents have been used for endoscopic treatment, dextranomer/hyaluronic acid is the only bulking agent currently approved by the U.S. Food and Drug Administration for treating VUR. Endoscopic treatment of VUR has gained great popularity owing to several obvious benefits, including short operative time, short hospital stay, minimal invasiveness, high efficacy, low complication rate, and reduced cost. Initially, the success rates of endoscopic treatment have been lower than that of open antireflux surgery. However, because injection techniques have been developed, a recent study showed higher success rates of endoscopic treatment than open surgery in the treatment of patients with intermediate- and high-grade VUR. Despite the controversy surrounding its effectiveness, endoscopic treatment is considered a valuable treatment option and viable alternative to long-term antibiotic prophylaxis.

  10. Endoscopic Versus Open Cubital Tunnel Release

    Science.gov (United States)

    Aldekhayel, Salah; Govshievich, Alexander; Lee, James; Tahiri, Youssef; Luc, Mario

    2016-01-01

    Background: Several surgical techniques exist for treatment of cubital tunnel syndrome. Endoscopic cubital tunnel release (ECTuR) has been recently reported as a promising minimally invasive technique. This study aims to compare outcomes and complications of open cubital tunnel release (OCTuR) and ECTuR in the treatment of idiopathic cubital tunnel syndrome. Methods: A systematic review of the literature (1980-2014) identified 118 citations. Studies including adults with idiopathic cubital tunnel treated exclusively by ECTuR or OCTuR were included. Outcomes of interest were postoperative grading, complications, number of reoperations, and the need for intraoperative conversion to another technique. Postoperative outcomes were combined into a uniform scale with 4 categories: “excellent,” “good,” “fair,” and “poor.” Results: Twenty studies met the inclusion criteria (17 observational and 3 comparative), representing 425 open and 556 endoscopic decompressions. In the open group, 79.8% experienced “good” or “excellent” results with 12% complication rate and 2.8% reoperation rate. In the endoscopic group, 81.8% experienced “good” or “excellent” results with 9% complication rate and 1.6% reoperation rate. Meta-analysis of 3 comparative studies demonstrated a significantly lower overall complication rate with ECTuR. Subgroup analysis of complications revealed a significantly higher incidence of scar tenderness and elbow pain with OCTuR. Conclusions: The current study demonstrates similar effectiveness between the endoscopic (ECTuR) and open (OCTuR) techniques for treatment of idiopathic cubital tunnel syndrome with similar outcomes, complication profiles, and reoperation rates. PMID:27418887

  11. BIODEGRADABLE NASAL TAMPONADE DURING ENDONASAL ENDOSCOPIC DACRYOCYSTORHINOSTOMY

    Directory of Open Access Journals (Sweden)

    M. I. Shlyakhtov

    2015-01-01

    Full Text Available Aim. To analyze the efficacy of novel biodegradable Nasopore® nasal dressing for bleeding prevention in postoperative period after endonasal endoscopic dacryocystorhinostomy.Patients and methods. Two cohorts of patients who underwent endonasal endoscopic dacryocystorhinostomy were analyzed. In these patients, the area of rhinostoma was plugged with biodegradable Nasopore® or non-biodegradable Merocel® nasal dressing to prevent bleeding. 37 women and 9 men (mean age 56 years underwent the surgery which was performed under anesthetic using standard technology and endoscopic instruments. Nasopore® and Merocel® were used in 20 and 26 cases, respectively. Re-bleeding rate and the presence of post-operative discomfort were assessed. Specifics of nasal mucosa regeneration, formation of granulations, synechiae, and membranes in the area of nasolacrimal anastamosis were noted.Results. Efficacy of nasal dressing was assessed in the first week after the surgery. In group 1 (Nasopore®, no nasal bleeding was observed and no re-tamponade was required. In group 2 (Merocel®, nasal bleeding occurred in 10 cases (38.4% after nasal dressing removal, and re-tamponade was performed in 8 patients (30.8%. Main disadvantage of Merocel® is the «sawing» effect due to the pore texture of its surface. This property resulted in the bleeding after nasal dressing removal. None of group 1 patients complained of severe discomfort while 19% of group 2 patients experienced significant discomfort.Conclusions. Biodegradable Nasopore® nasal dressing use in endonasal endoscopic dacryocystorhinostomy prevents recurrent post-operative nasal bleedings, decreases patient discomfort, provides better anatomical and functional outcomes and improves quality of life and medical social rehabilitation. 

  12. Outcome of Endoscopic Transsphenoidal Surgery for Acromegaly.

    Science.gov (United States)

    Kim, Jung Hee; Hur, Kyu Yeon; Lee, Jung Hyun; Lee, Ji Hyun; Se, Young-Bem; Kim, Hey In; Lee, Seung Hoon; Nam, Do-Hyun; Kim, Seong Yeon; Kim, Kwang-Won; Kong, Doo-Sik; Kim, Yong Hwy

    2017-08-01

    Endoscopic transsphenoidal surgery has recently been introduced in pituitary surgery. We investigated outcomes and complications of endoscopic surgery in 2 referral centers in Korea. We enrolled 134 patients with acromegaly (microadenomas, n = 15; macroadenomas, n = 119) who underwent endoscopic transsphenoidal surgery at Seoul National University Hospital (n = 74) and Samsung Medical Center (n = 60) between January 2009 and March 2016. Remission was defined as having a normal insulin-like growth factor-1 and a suppressed growth hormone (GH) <1 ng/mL during an oral glucose tolerance test. Remission was achieved in 73.1% of patients, including 13 of 15 microadenoma patients (86.7%) and 86 of 119 macroadenoma patients (72.3%). A multivariate analysis to determine a predictor of biochemical remission demonstrated that absence of cavernous sinus invasion and immediate postoperative GH levels <2.5 ng/dL were significant predictors of remission (adjusted odds ratio [OR], 5.14; 95% confidence interval [CI], 1.52-17.3 and OR, 9.60; 95% CI, 3.41-26.9, respectively). After surgery, normal pituitary function was maintained in 34 patients (25.4%). Sixty-four patients (47.7%) presented complete (n = 59, 44.0%) or incomplete (n = 5, 3.7%) recovery of pituitary function. Hypopituitarism persisted in 20 patients (14.9%) and worsened in 16 patients (11.9%). Postoperatively, transient diabetes insipidus was reported in 52 patients (38.8%) but only persisted in 2 patients (1.5%). Other postoperative complications were epistaxis (n = 2), cerebral fluid leakage (n = 4), infection (n = 1), and intracerebral hemorrhage (n = 1). Endoscopic transsphenoidal surgery for acromegaly presented high remission rates and a low incidence of endocrine deficits and complications. Regardless of surgical techniques, invasive pituitary tumors were associated with poor outcome. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Quantum-Non-Demolition Endoscopic Tomography

    OpenAIRE

    Fortunato, Mauro; Tombesi, Paolo; Schleich, Wolfgang P.

    1998-01-01

    We present a new indirect method to measure the quantum state of a single mode of the electromagnetic field in a cavity. Our proposal combines the idea of (endoscopic) probing and that of tomography in the sense that the signal field is coupled via a quantum-non-demolition Hamiltonian to a meter field on which then quantum state tomography is performed using balanced homodyne detection. This technique provides full information about the signal state. We also discuss the influence of the measu...

  14. Endoscopic variceal ligation-induced ulcer bleeding

    Science.gov (United States)

    Cho, Eunae; Jun, Chung Hwan; Cho, Sung Bum; Park, Chang Hwan; Kim, Hyun Soo; Choi, Sung Kyu; Rew, Jong Sun

    2017-01-01

    Abstract This study was aimed to determine the risk factors of endoscopic variceal ligation-(EVL) induced ulcer bleeding. The prevalence of EVL-induced ulcer bleeding is reported to be 3.6%. However, there are only limited reports of this serious complication, and the risk factors and the treatment methods are not well established. A total of 430 patients who had undergone EVL in Chonnam National University Hospital from January 2014 to October 2016 were studied. EVL was performed for prophylaxis or acute hemorrhage. The patients were classified into 2 groups: a bleeding group (n = 33) and a non-bleeding group (n = 397). The patients who had endoscopically confirmed EVL-induced ulcer bleeding were included in the bleeding group. EVL-induced ulcer bleeding occurred in 7.7% (n = 33) of the patients. In a multivariate analysis, model for end-stage liver disease (MELD) score >10 (odds ratio [OR]: 3.42, 95% confidence interval [CI]: 1.10–10.64), concomitant GV F3 (OR: 14.1, 95% CI: 2.84–71.43), and detachment of o-ring bands on follow-up endoscopy (OR: 8.06, 95% CI: 2.55–25.64) were independent predictive factors of EVL-induced ulcer bleeding. Various endoscopic modalities were attempted for hemostasis (EVL in 8 cases [24.2%], endoscopic variceal obturation [EVO] with cyanoacrylate in 6 cases [18.2%], argon plasma coagulation [APC] in 1 case (3%), Sengstaken–Blakemore (SB) tube in 3 cases [9.1%]), and proton pump inhibitor therapy only in 15 cases (45.5%). MELD score >10, concomitant GV F3, and detachment of o-ring bands on follow-up endoscopy are risk factors for EVL-induced ulcer bleeding. PMID:28614248

  15. Endoscopic Evaluation of the Small Intestine

    Directory of Open Access Journals (Sweden)

    Steven J Shields

    2002-01-01

    Full Text Available Technological achievements in the area of endoscope design and development have resulted in instruments capable of advancing beyond the reach of simple gastroscopes. Such instruments, known as enteroscopes, form the bases of small bowel endoscopy. Recent widespread use of enteroscopes have contributed significantly to the understanding of small intestinal pathology and improved the ability to diagnose and treat patients with intestinal bleeding sources.

  16. Endoscopic vs microscopic myringoplasty: a different perspective.

    Science.gov (United States)

    Lade, Himani; Choudhary, Santosha Ram; Vashishth, Ashish

    2014-07-01

    The objectives of this study were to ascertain the feasibility of transcanal endoscopic underlay myringoplasty using temporalis fascia and compare the results with microscopic myringoplasty. This prospective randomized trial included 60 patients with mucosal chronic otitis media with tympanic membrane perforations of all sizes and locations apart from posteriorly based small or moderate sized perforations. In the endoscopy group, 30 patients underwent exclusive transcanal myringoplasty using tympanomeatal flap elevation with underlay graft placement. In the microscopy group, 30 patients underwent myringoplasty using the postaural approach. Intra-operative variables compared were canalplasty and canal wall curettage for assessment of ossicular status. Graft uptake, hearing outcomes using pure tone audiometry and subjective cosmetic outcomes were assessed 24 weeks post-operatively and compared in the two groups. Resident feedback on the feasibility of endoscopic myringoplasty was obtained using a questionnaire. In the microscopy group, 5/30 patients required canalplasty due to canal overhangs and 4/30 required canal wall curettage for ossicular assessment, whereas none of the patients in the endoscopy group required these procedures. A graft uptake rate of 83.3% was observed in both groups post-operatively after 24 weeks. Mean air-bone gap pre- and post-operatively in the endoscopy group was 28.5 and 18.13 dB, respectively, whereas these values were 32.4 and 16.9 dB, respectively, in the microscopy group. Subjective cosmetic outcomes were better in the endoscopy group. Resident feedback on endoscopic myringoplasty was positive. Endoscopic myringoplasty appears to be an effective alternative to microscopic myringoplasty and results in excellent hearing with good cosmetic outcomes.

  17. One-Way Compatibility, Two-Way Compatibility and Entry in Network Industries

    OpenAIRE

    Fabio Maria Manenti; Ernesto Somma

    2002-01-01

    We study the strategic choice of compatibility between two initially incompatible network goods in a two-stage game played by an incumbent and an entrant firm. Compatibility may be achieved by means of a converter. We derive a number of results under different assumptions about the nature of the converter (one-way vs two-way), the existence of property rights and the possibility of side payments. With incompatibility, entry deterrence occurs for sufficiently strong network effects. In the cas...

  18. Nanocomposite fibers and film containing polyolefin and surface-modified carbon nanotubes

    Science.gov (United States)

    Chu,Benjamin; Hsiao, Benjamin S.

    2010-01-26

    Methods for modifying carbon nanotubes with organic compounds are disclosed. The modified carbon nanotubes have enhanced compatibility with polyolefins. Nanocomposites of the organo-modified carbon nanotubes and polyolefins can be used to produce both fibers and films having enhanced mechanical and electrical properties, especially the elongation-to-break ratio and the toughness of the fibers and/or films.

  19. [Endoscopic implantation of endoprostheses in incurable esophageal and cardia cancer].

    Science.gov (United States)

    Wiesenhaken, U; Rogos, R

    1990-03-01

    The palliative treatment of tumorous stenosis of the esophagus and cardio-esophageal region by intubation with an endoprosthesis leads to an improved quality of life. The used endoscopic positioning provides better results than the surgical procedure. This method is easy in handling and has only few complications. The endoscopic positioning of endoprosthesis is also a really alternative of alimentary fistula. The positioning of plastic prosthesis under endoscopic control should be given preference in the palliative treatment of obstructing cardio-esophageal malignancy.

  20. Treatment Strategy after Incomplete Endoscopic Resection of Early Gastric Cancer

    OpenAIRE

    Kim, Sang Gyun

    2016-01-01

    Endoscopic resection of early gastric cancer is defined as incomplete when tumor cells are found at the resection margin upon histopathological examination. However, a tumor-positive resection margin does not always indicate residual tumor; it can also be caused by tissue contraction during fixation, by the cautery effect during endoscopic resection, or by incorrect histopathological mapping. Cases of highly suspicious residual tumor require additional endoscopic or surgical resection. For in...

  1. Treatment of nonseptic bursitis with endoscopic surgery

    Directory of Open Access Journals (Sweden)

    Azad Yıldırım

    2015-09-01

    Full Text Available Objective: The aim of this study was to show that endoscopic surgery is a simple and acceptable method for various problems associated with wounds, range of motion and that such surgery ensures an early return to work after treatment of nonresponding nonseptic bursitis. Methods: Thirty-two patients with nonseptic bursitis caused by repeated minor trauma that did not respond to medical treatment from 2008 to 2012 were included in this study. Radiographic [anteroposterior and lateral], ultrasound, macro and microscopic analyses of drainage liquid and aerobic and anaerobic cultures were obtained from the patients for the diagnosis. Results: The mean age was 40.8 years. Fifteen patients had prepatellar bursitis, 13 had olecranon bursitis and 4 had ankle bursitis. Two patients had a history of falling on their knee. The other patients had a history of repetitive stimulation .The mean follow up period was 2.6 years [range. 2-5 years] and no medical complications occurred after the endoscopic surgery; such as scarring, loss of sensation and infection. One recurrence in response to medical treatment was observed. Conclusion: Endoscopic bursectomy is a short and acceptable procedure with excellent results in terms of returning to work early and minimal wound related problems. J Clin Exp Invest 2015; 6 (3: 220-223

  2. Peroral endoscopic myotomy (POEM) for esophageal achalasia.

    Science.gov (United States)

    Inoue, H; Minami, H; Kobayashi, Y; Sato, Y; Kaga, M; Suzuki, M; Satodate, H; Odaka, N; Itoh, H; Kudo, S

    2010-04-01

    Peroral endoscopic myotomy (POEM) was developed by our group to provide a less invasive permanent treatment for esophageal achalasia. POEM was performed in 17 consecutive patients with achalasia (10 men, 7 women; mean age 41.4 years). A long submucosal tunnel was created (mean length 12.4 cm), followed by endoscopic myotomy of circular muscle bundles of a mean total length of 8.1 cm (6.1 cm in distal esophagus and 2.0 cm in cardia). Smooth passage of an endoscope through the gastroesophageal junction was confirmed at the end of the procedure. In all cases POEM significantly reduced the dysphagia symptom score (from mean 10 to 1.3; P = 0.0003) and the resting lower esophageal sphincter (LES) pressure (from mean 52.4 mmHg to 19.9 mmHg; P = 0.0001). No serious complications related to POEM were encountered. During follow-up (mean 5 months), additional treatment or medication was necessary in only one patient (case 17) who developed reflux esophagitis (Los Angeles classification B); this was well controlled with regular intake of protein pump inhibitors (PPIs). The short-term outcome of POEM for achalasia was excellent; further studies on long-term efficacy and on comparison of POEM with other interventional therapies are awaited. Georg Thieme Verlag KG Stuttgart. New York.

  3. Esophageal Intramural Pseudodiverticulosis: A Rare Endoscopic Finding

    Directory of Open Access Journals (Sweden)

    Luciana Lopes de Oliveira

    2013-01-01

    Full Text Available A 76-year-old woman, presenting with a 4-year history of progressive dysphagia, was submitted to endoscopic examination. The upper endoscopy revealed a proximal esophageal stricture and inflammatory mucosa associated with multiples small orifices in the esophageal wall, some of them fulfilled with white spots suggestive of fungal infection. This was a typical endoscopic finding of esophageal intramural pseudodiverticulosis, a benign and rare condition, related to chronic esophagitis and others comorbid states, such as gastroesophageal reflux disease or infectious esophagitis, diabetes mellitus, alcohol consumption, and achalasia. Dysphagia is the predominant symptom and can be accompanied by esophageal stricture in 80% to 90% of patients. The pathogenesis is unknown, and as the pseudodiverticulosis is an intramural finding, endoscopy biopsies are inconclusive. The main histological finding is dilation of the submucosal glands excretory ducts, probably obstructed by inflammatory cells. The treatment consists in management of the underlying diseases and symptoms relief. In this particular case, the patient was submitted to antifungal drugs followed by endoscopic dilation with thermoplastic bougies, with satisfactory improvement of dysphagia.

  4. Frontiers of robotic endoscopic capsules: a review.

    Science.gov (United States)

    Ciuti, Gastone; Caliò, R; Camboni, D; Neri, L; Bianchi, F; Arezzo, A; Koulaouzidis, A; Schostek, S; Stoyanov, D; Oddo, C M; Magnani, B; Menciassi, A; Morino, M; Schurr, M O; Dario, P

    2016-01-01

    Digestive diseases are a major burden for society and healthcare systems, and with an aging population, the importance of their effective management will become critical. Healthcare systems worldwide already struggle to insure quality and affordability of healthcare delivery and this will be a significant challenge in the midterm future. Wireless capsule endoscopy (WCE), introduced in 2000 by Given Imaging Ltd., is an example of disruptive technology and represents an attractive alternative to traditional diagnostic techniques. WCE overcomes conventional endoscopy enabling inspection of the digestive system without discomfort or the need for sedation. Thus, it has the advantage of encouraging patients to undergo gastrointestinal (GI) tract examinations and of facilitating mass screening programmes. With the integration of further capabilities based on microrobotics, e.g. active locomotion and embedded therapeutic modules, WCE could become the key-technology for GI diagnosis and treatment. This review presents a research update on WCE and describes the state-of-the-art of current endoscopic devices with a focus on research-oriented robotic capsule endoscopes enabled by microsystem technologies. The article also presents a visionary perspective on WCE potential for screening, diagnostic and therapeutic endoscopic procedures.

  5. Endoscopic transnasal approach for removing pituitary tumors

    Directory of Open Access Journals (Sweden)

    Mirian Cabral Moreira de Castro

    2014-05-01

    Full Text Available To describe a series of 129 consecutive patients submitted to the resection of pituitary tumors using the endoscopic transsphenoidal approach in a public medical center. Method: Retrospective analysis based on the records of patients submitted to the resection of a pituitary tumor through the endoscopic transsphenoidal approach between 2004 and 2009. Results: One hundred and twenty-nine records were analyzed. The tumor was non-secreting in 96 (74.42% and secreting in 33 patients (22.58%. Out of the secretory tumors, the most prevalent was the growth hormone producer (7.65%, followed by the prolactinoma, (6.98%. Eleven patients developed cerebral spinal fluid (CSF fistulas, and four of them developed meningitis. One patient died due to intracerebral hemorrhage in the postoperative period. Conclusion: The endoscopic transsphenoidal approach to sellar tumors proved to be safe when the majority of the tumors were non-secreting. The most frequent complication was CSF. This technique can be done even in a public hospital with financial limits, since the health professionals are integrated.

  6. Novel endoscopic management of buried bumper syndrome in percutaneous endoscopic gastrostomy: The Olympus HookKnife.

    Science.gov (United States)

    Wolpert, Laura E; Summers, Dominic M; Tsang, Andrew

    2017-09-21

    Buried bumper syndrome (BBS) is an uncommon but serious complication of percutaneous endoscopic ga-strostomy. It involves the internal fixation device, or "bumper", migrating into the gastric wall and subsequent mucosal overgrowth. We described a case series of four patients with BBS treated with a novel endoscopic technique using a HookKnife between June 2016 and February 2017. The HookKnife is a rotating L-shaped cutting wire designed for hooking tissue and pulling it away from the gastric wall towards the lumen. The technique was successful in all four cases with no complications. Each patient was discharged on the day of treatment. The HookKnife is a manoeuvrable, safe and effective device for endoscopic removal of buried bumpers and could avoid surgery in a high risk group of patients. To our knowledge this technique has not been described previously. We suggest that this technique should be added to the treatment algorithms for managing BBS.

  7. Automation of electromagnetic compatability (EMC) test facilities

    Science.gov (United States)

    Harrison, C. A.

    1986-01-01

    Efforts to automate electromagnetic compatibility (EMC) test facilities at Marshall Space Flight Center are discussed. The present facility is used to accomplish a battery of nine standard tests (with limited variations) deigned to certify EMC of Shuttle payload equipment. Prior to this project, some EMC tests were partially automated, but others were performed manually. Software was developed to integrate all testing by means of a desk-top computer-controller. Near real-time data reduction and onboard graphics capabilities permit immediate assessment of test results. Provisions for disk storage of test data permit computer production of the test engineer's certification report. Software flexibility permits variation in the tests procedure, the ability to examine more closely those frequency bands which indicate compatibility problems, and the capability to incorporate additional test procedures.

  8. Paleogeographical reconstructions compatible with Earth dilatation

    Directory of Open Access Journals (Sweden)

    G. Scalera

    1998-06-01

    Full Text Available The present research concerns the study of the possibility of an increase in the size of the Earthbecause of a still unknown process. After a previous recognition of the existence in the Pacific of shape conformities in a number of pairs of continental and oceanic boundaries (Scalera, 1991, 1993a, a search for compatibility of these results with independent data sets, paleomagnetic and geological and paleontological was undertaken. The conclusion is that the Earth's dilatation is compatible with the used data, while nothing can be affirmed with certainty about the dilatation process or its continuity or discontinuity through geological time. A tentative model of the evolution of the trench-arc-backarc systems has been provided, tuning it in agreement with a dilatational planet.

  9. Experience with endoscopic holmium laser in the pediatric population

    Science.gov (United States)

    Merguerian, Paul A.; Reddy, Pramod P.; Barrieras, Diego; Bagli, Darius J.; McLorie, Gordon A.; Khoury, Antoine E.

    1999-06-01

    Introduction: Due to the unavailability of suitable endoscopic instruments, pediatric patients have not benefited fully from the technological advances in the endoscopic management of the upper urinary tract. This limitation may be overcome with the Holmuim:Yttrium-Aluminum-Garnet(Ho:YAG) laser delivered via small instruments. To date, there is no published report on the use of this modality in children. Purpose: We evaluated the indications, efficacy, and complications of endourological Ho:YAG laser surgery in the treatment of pediatric urolithiasis, posterior urethral valves, ureterocele and ureteropelvic junction obstruction. Methods: The patient population included 10 children with renal, ureteral and bladder calculi, 2 children with posterior urethral valves, 2 children with obstructing ureteroceles, 2 children with ureteropelvic junction obstruction and 1 child with a urethral stricture. Access to the lesions was either antegrade via a percutaneous nephrostomy tract or retrograde via the urethra. A solid state Ho:YAG laser with maximum output of 30 watts (New Star lasers, Auburn, CA) was utilized as the energy source. Results: A total of 10 patients underwent laser lithotripsy. The means age of the patients was 9 yrs (5-13 yrs). The average surface area of the calculi as 425.2 mm2 (92-1645 mm2). 8 of the patients required one procedure to render them stone free, one patient had a staghorn calculus filling every calyx of a solitary kidney requiring multiple treatments and one other patient with a staghorn calculus required 2 treatments. There were no complications related to the laser lithotripsy. Two newborn underwent successful ablation of po sterious urethral valves. Two infants underwent incision of obstructing ureteroceles with decompression of the ureterocele on postoperative ultrasound. Two children underwent endypyelotomy for ureteropelvic junction obstruction. One was successful an done required an open procedure to correct the obstruction. One child

  10. Endoscopic removal of a dislocated tumour prothesis from the stomach

    Energy Technology Data Exchange (ETDEWEB)

    Rueckauer, K.; Dinkel, E.

    1985-09-01

    Endoscopic pertubation of oesophagogustric neoplasms is an established method of palliative treatment. The dislocated plastic prosthesis may be removed with difficulties from the stomach endoscopically. A simple technique for endoscopic removal of the prosthesis is described. The tube can be precisely centred within the oesophageal lumen by use of an intestinal decompression tube and additional guidance by the endoscopic retraction forceps. Thus gross damge of the exophytic tumor tissue with bleeding or perforation sequelae can be avoided. Injury to the patient does not exceed that caused by an ordinary gastroscopy.

  11. Early Gastric Cancer: Current Advances of Endoscopic Diagnosis and Treatment

    Directory of Open Access Journals (Sweden)

    Linlin Zhu

    2016-01-01

    Full Text Available Endoscopy is a major method for early gastric cancer screening because of its high detection rate, but its diagnostic accuracy depends heavily on the availability of endoscopic instruments. Many novel endoscopic techniques have been shown to increase the diagnostic yield of early gastric cancer. With the improved detection rate of EGC, the endoscopic treatment has become widespread due to advances in the instruments available and endoscopist’s experience. The aim of this review is to summarize frequently-used endoscopic diagnosis and treatment in early gastric cancer (EGC.

  12. Nefopam Reduces Dysesthesia after Percutaneous Endoscopic Lumbar Discectomy

    National Research Council Canada - National Science Library

    Ok, Young Min; Cheon, Ji Hyun; Choi, Eun Ji; Chang, Eun Jung; Lee, Ho Myung; Kim, Kyung Hoon

    2016-01-01

    Neuropathic pain, including paresthesia/dysesthesia in the lower extremities, always develops and remains for at least one month, to variable degrees, after percutaneous endoscopic lumbar discectomy (PELD...

  13. Migration and sustainability - compatible or contradictory?

    DEFF Research Database (Denmark)

    Røpke, Inge

    2006-01-01

    When the migration issue is discussed in a sustainability perspective, two questions are vital: 1) What is the relationship between migration and the global population growth? 2) What is the relationship between migration and consumption growth, and how does migration influence the distribution o...... of consumption possibilities both between and within industrialized and developing countries? Based on responses to these questions, it is argued that reasonably managed migration will be compatible with sustainable development....

  14. Group Discounts Compatible with Buyer Privacy

    OpenAIRE

    Domingo-Ferrer, Josep; Blanco-Justicia, Alberto

    2014-01-01

    We show how group discounts can be offered without forcing buyers to surrender their anonymity, as long as buyers can use their own computing devices (e.g. smartphone, tablet or computer) to perform a purchase. Specifically, we present a protocol for privacy-preserving group discounts. The protocol allows a group of buyers to prove how many they are without disclosing their identities. Coupled with an anonymous payment system, this makes group discounts compatible with buyer privacy (that is,...

  15. Oxygen Compatibility Testing of Composite Materials

    Science.gov (United States)

    Graf, Neil A.; Hudgins, Richard J.; McBain, Michael

    2000-01-01

    The development of polymer composite liquid oxygen LO2 tanks is a critical step in creating the next generation of launch vehicles. Future launch vehicles need to minimize the gross liftoff weight (GLOW), which is possible due to the 25%-40% reduction in weight that composite materials could provide over current aluminum technology. Although a composite LO2 tank makes these weight savings feasible, composite materials have not historically been viewed as "LO2 compatible." To be considered LO2 compatible, materials must be selected that will resist any type of detrimental, combustible reaction when exposed to usage environments. This is traditionally evaluated using a standard set of tests. However, materials that do not pass the standard tests can be shown to be safe for a particular application. This paper documents the approach and results of a joint NASA/Lockheed Martin program to select and verify LO2 compatible composite materials for liquid oxygen fuel tanks. The test approach developed included tests such as mechanical impact, particle impact, puncture, electrostatic discharge, friction, and pyrotechnic shock. These tests showed that composite liquid oxygen tanks are indeed feasible for future launch vehicles.

  16. An MR-compatible neonatal incubator

    Science.gov (United States)

    Paley, M N J; Hart, A R; Lait, M; Griffiths, P D

    2012-01-01

    Objectives To develop a neonatal MR-compatible incubator for transporting babies between a neonatal intensive care unit and an MRI unit that is within the same hospital but geographically separate. Methods The system was strapped to a standard MR-compatible patient trolley, which provides space for resuscitation outside the incubator. A constant-temperature exothermic heat pad was used to maintain temperature together with a logging fluoro-optic temperature monitor and alarm system. The system has been designed to accommodate standard knee-sized coils from the major MR manufacturers. The original incubator was constructed from carbon fibre, but this required modification to prevent radiofrequency shading artefacts due to the conducting properties of the carbon fibre. A high-tensile polyester material was used, which combined light weight with high impact strength. The system could be moved onto the patient bed with the coils and infant in place by one technologist. Results Studies in eight neonatal patients produced high quality 1.5 T MR images with low motion artefacts. The incubator should also be compatible with imaging in 3 T MR systems, although further work is required to establish this. Images were acquired using both rapid and high-resolution sequences, including three-dimensional volumes, proton spectra and diffusion weighting. Conclusion The incubator provides a safe, quiet environment for neonates during transport and imaging, at low cost. PMID:22167517

  17. Double Retort System for Materials Compatibility Testing

    Energy Technology Data Exchange (ETDEWEB)

    V. Munne; EV Carelli

    2006-02-23

    With Naval Reactors (NR) approval of the Naval Reactors Prime Contractor Team (NRPCT) recommendation to develop a gas cooled reactor directly coupled to a Brayton power conversion system as the Space Nuclear Power Plant (SNPP) for Project Prometheus (References a and b) there was a need to investigate compatibility between the various materials to be used throughout the SNPP. Of particular interest was the transport of interstitial impurities from the nickel-base superalloys, which were leading candidates for most of the piping and turbine components to the refractory metal alloys planned for use in the reactor core. This kind of contamination has the potential to affect the lifetime of the core materials. This letter provides technical information regarding the assembly and operation of a double retort materials compatibility testing system and initial experimental results. The use of a double retort system to test materials compatibility through the transfer of impurities from a source to a sink material is described here. The system has independent temperature control for both materials and is far less complex than closed loops. The system is described in detail and the results of three experiments are presented.

  18. Energy scaling of mode-locked fiber lasers with chirally-coupled core fiber

    Science.gov (United States)

    Lefrancois, Simon; Sosnowski, Thomas S.; Liu, Chi-Hung; Galvanauskas, Almantas; Wise, Frank W.

    2011-01-01

    We report a mode-locked dissipative soliton laser based on large-mode-area chirally-coupled-core Yb-doped fiber. This demonstrates scaling of a fiber oscillator to large mode area in a format that directly holds the lowest-order mode and that is also compatible with standard fiber integration. With an all-normal-dispersion cavity design, chirped pulse energies above 40 nJ are obtained with dechirped durations below 200 fs. Using a shorter fiber, dechirped durations close to 100 fs are achieved at pump-limited energies. The achievement of correct energy scaling is evidence of single-transverse-mode operation, which is confirmed by beam-quality and spectral-interference measurements. PMID:21369169

  19. Dual-modality smartphone endoscope for cervical pre-cancer detection (Conference Presentation)

    Science.gov (United States)

    Hong, Xiangqian; Yu, Bing

    2017-02-01

    Early detection is the key to the prevention of cervical cancer. There is an urgent need for a portable, affordable, and easy-to-use device for cervical pre-cancer detection, especially in low-resource settings. We have developed a dual-modality fiber-optic endoscope system (SmartME) that integrates high-resolution fluorescence imaging (FLI) and quantitative diffuse reflectance spectroscopy (DRS) onto a smartphone platform. The SmartME consists of a smartphone, a miniature fiber-optic endoscope, a phone attachment containing imaging optics, and a smartphone application (app). FLI is obtained by painting the tissue with a contrast agent (e.g., proflavine), illuminating the tissue and collecting its fluorescence images through an imaging bundle that is coupled to the phone camera. DRS is achieved by using a white LED, attaching additional source and detection fibers to the imaging bundle, and converting the phone camera into a spectrometer. The app collects images/spectra and transmits them to a remote server for analysis to extract the tissue parameters, including nuclear-to-cytoplasm ratio (calculated from FLI), concentrations of oxyhemoglobin (HbO2) and deoxyhemoglobin (Hb) as well as scattering (measured by DRS). These parameters can be used to detect cervical dysplasia. Our preliminary studies have demonstrated that the SmartME can clearly visualize the nuclei in living cells and in vivo biological samples, with a high spatial resolution of 3.1μm. The device can also measure tissue absorption and scattering properties with comparable accuracy to those of a benchtop DRS system. The SmartME has great potential to provide a compact, affordable, and `smart' solution for early detection of neoplastic changes in cervix.

  20. Hansen solubility parameters for a carbon fiber/epoxy composite

    DEFF Research Database (Denmark)

    Launay, Helene; Hansen, Charles M.; Almdal, Kristoffer

    2007-01-01

    In this study, the physical affinity between an epoxy matrix and oxidized, unsized carbon fibers has been evaluated using Hansen solubility (cohesion) parameters (HSP). A strong physical compatibility has been shown, since their respective HSP are close. The use of a glassy carbon substrate...

  1. Multimaterial preform coextrusion for robust chalcogenide optical fibers and tapers.

    Science.gov (United States)

    Tao, Guangming; Shabahang, Soroush; Banaei, Esmaeil-Hooman; Kaufman, Joshua J; Abouraddy, Ayman F

    2012-07-01

    The development of robust infrared fibers is crucial for harnessing the capabilities of new mid-infrared lasers. We present a novel approach to the fabrication of chalcogenide glass fiber preforms: one-step multimaterial extrusion. The preform consists of a glass core and cladding surrounded by a built-in, thermally compatible, polymer jacket for mechanical support. Using this approach we extrude several preform structures and draw them into robust composite fibers. Furthermore, the polymer cladding allows us to produce robust tapers with submicrometer core diameter.

  2. [Miscellaneous Compatibility Determinations : Rocky Mountain Arsenal NWR : 2017

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — Linked through this record are compatibility determinations from the Rocky Mountain Arsenal between the years 2005 and 2014. Included is a 2005 Compatibility...

  3. Endoscopic ultrasound, endoscopic sonoelastography, and strain ratio evaluation of lymph nodes with histology as gold standard

    DEFF Research Database (Denmark)

    Larsen, Michael Hareskov; Fristrup, Claus Wilki; Hansen, Tine Plato

    2012-01-01

    BACKGROUND AND STUDY AIMS: Accurate lymph node staging is essential for the selection of an optimal treatment in patients with upper gastrointestinal cancer. Endoscopic ultrasound (EUS) and fine-needle aspiration (FNA) are considered to be the most accurate method for locoregional staging. Endosc...

  4. 46 CFR Figure 1 to Part 150 - Compatibility Chart

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Compatibility Chart 1 Figure 1 to Part 150 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES COMPATIBILITY OF CARGOES Pt. 150, Fig. 1 Figure 1 to Part 150—Compatibility Chart EC02FE91.079 ...

  5. 47 CFR 68.4 - Hearing aid-compatible telephones.

    Science.gov (United States)

    2010-10-01

    ... if it provides internal means for effective use with hearing aids that are designed to be compatible... 47 Telecommunication 3 2010-10-01 2010-10-01 false Hearing aid-compatible telephones. 68.4 Section... (CONTINUED) CONNECTION OF TERMINAL EQUIPMENT TO THE TELEPHONE NETWORK General § 68.4 Hearing aid-compatible...

  6. The Effect of Birth Order on Roommate Compatibility

    Science.gov (United States)

    Schuh, John H.; Williams, Ondre J.

    1977-01-01

    A group of students were matched on the basis of compatible birth order; another was matched on the basis of conflicting birth order. After a month's experience in a residence hall their compatibility was examined. Students with conflicting birth order were more compatible than those with the same birth order. (Author)

  7. Design and evaluation of robotic steering of a flexible endoscope

    NARCIS (Netherlands)

    Ruiter, J.G.; Rozeboom, Esther; van der Voort, Mascha C.; Bonnema, M.; Broeders, Ivo Adriaan Maria Johannes

    2012-01-01

    In current flexible endoscopy the physician faces problems in manipulating the endoscope. A lot of experience is required to master the procedure. This paper describes the design of an add-on robotic module that improves the user interface of traditional endoscopes and allows a single physician to

  8. Is endoscopic nodular gastritis associated with premalignant lesions?

    Science.gov (United States)

    Niknam, R; Manafi, A; Maghbool, M; Kouhpayeh, A; Mahmoudi, L

    2015-06-01

    Nodularity on the gastric mucosa is occasionally seen in general practice. There is no consensus about the association of nodular gastritis and histological premalignant lesions. This study is designed to investigate the prevalence of histological premalignant lesions in dyspeptic patients with endoscopic nodular gastritis. Consecutive patients with endoscopic nodular gastritis were compared with an age- and sex-matched control group. Endoscopic nodular gastritis was defined as a miliary nodular appearance of the gastric mucosa on endoscopy. Biopsy samples of stomach tissue were examined for the presence of atrophic gastritis, intestinal metaplasia, and dysplasia. The presence of Helicobacter pylori infection was determined by histology. From 5366 evaluated patients, a total of 273 patients with endoscopic nodular gastritis and 1103 participants as control group were enrolled. H. pylori infection was detected in 87.5% of the patients with endoscopic nodular gastritis, whereas 73.8% of the control group were positive for H. pylori (p gastritis were significantly higher than in the control group. Prevalence of atrophic gastritis and complete intestinal metaplasia were also more frequent in patients with endoscopic nodular gastritis than in the control group. Dysplasia, incomplete intestinal metaplasia and H. pylori infection are significantly more frequent in patients with endoscopic nodular gastritis. Although further studies are needed before a clear conclusion can be reached, we suggest that endoscopic nodular gastritis might serve as a premalignant lesion and could be biopsied in all patients for the possibility of histological premalignancy, in addition to H. pylori infection.

  9. Correlation between Endoscopic and Histological Gastritis in South ...

    African Journals Online (AJOL)

    Background: Inflammation of the gastric mucosa is a common finding in the general population. It is also common in clinical practice for Endoscopists to make an impression of gastritis on the basis of the general endoscopic appearance of the gastric mucosa. This concept of “endoscopic gastritis” was further given credibility ...

  10. Diagnosing Helicobacter pylori infection in vivo by novel endoscopic techniques.

    Science.gov (United States)

    Ji, Rui; Li, Yan-Qing

    2014-07-28

    Infection with Helicobacter pylori (H. pylori) is a worldwide problem. Endoscopic observation of H. pylori infection in vivo would be helpful to obtain an immediate diagnosis. The aim of this review is to describe recent advances in endoscopic technology and to review the available literature pertaining to its clinical application in H. pylori infection. Endoscopic visualization of H. pylori infection is not always feasible using conventional endoscopy. Thus, advanced endoscopic techniques have been developed with the aim of providing a precise and ''real-time'' endoscopic diagnosis. Recently, new endoscopic techniques such as magnifying endoscopy, narrow band imaging, I-Scan, endocytoscopy and endomicroscopy help focus examination of the stomach to diagnose disease in a time-efficient manner, and the analysis of mucosal surface details is beginning to resemble histologic examination. The new detailed images have enabled endoscopists to observe microscopic structures, such as gastric pit patterns, microvessels and cell morphology. Accordingly, endoscopic prediction of H. pylori infection is possible by analysis of surface architecture of the mucosa, which influences the clinical management. These endoscopic techniques might lead us to easier diagnosis and treatment of H. pylori-related diseases.

  11. Endoscopic Resection of a Prominent Median Lobe During TURP: a ...

    African Journals Online (AJOL)

    Endoscopic Resection of a Prominent Median Lobe During TURP: a Simple Technique to Avoid Sub- Trigonal Resection. AA Attia, MTA Al-Hak. Abstract. No Abstract. Key Words: Benign prostatic hyperplasia, surgery, Transurethral resection of prostate, Endoscopic resection, prominent median lobe. Full Text: EMAIL FREE ...

  12. Endoscopic removal of nasal septum chondrosarcoma in paediatric patient

    Directory of Open Access Journals (Sweden)

    Muhammad Nasri Abu Bakar

    2014-07-01

    We report a boy with progressive history of nasal obstruction and epistaxis. Nasal endoscopy revealed a mass arising from nasal septum. Endoscopic excision of the tumour was successfully done followed by radiotherapy. Endoscopic excision of chondrosarcoma of the nasal septum in its early stage should be considered for better outcome.

  13. Endoscopic and histologic healing of Crohn's (ileo-) colitis with azathioprine

    NARCIS (Netherlands)

    D'Haens, G.; Geboes, K.; Rutgeerts, P.

    1999-01-01

    The correlation between disease activity and endoscopic findings in Crohn's disease is poor. Corticosteroids induce symptom relief without consistent improvement of endoscopic lesions. Our aim was to examine the effect of azathioprine therapy on healing of inflammatory lesions in patients with

  14. External versus endoscopic dacryocystorhinostomy for congenital nasolacrimal duct obstruction

    Directory of Open Access Journals (Sweden)

    Mortada A Abozaid

    2015-01-01

    Both approaches of pediatric DCR - that is, external and endoscopic - have comparable success rates, although the endoscopic approach has the advantages of avoidance of skin incision, preservation of the pump mechanism, and the ability to address other nasal pathologies at the time of surgery.

  15. Endoscopic treatment of pancreatic stones in patients with chronic pancreatitis

    NARCIS (Netherlands)

    Smits, M. E.; Rauws, E. A.; Tytgat, G. N.; Huibregtse, K.

    1996-01-01

    The aim of our study was to evaluate the long-term results of endoscopic pancreatic stone removal in patients with chronic pancreatitis. We retrospectively included 53 patients with chronic pancreatitis, in whom an attempt was made at endoscopic stone removal between 1984 and 1993. Patients

  16. Advances in colonic imaging: new endoscopic imaging methods

    NARCIS (Netherlands)

    Dekker, Evelien; Fockens, Paul

    2005-01-01

    There is a need for better endoscopic visualization in specific circumstances like detection of flat colorectal lesions and dysplasia-screening in ulcerative colitis. Chromoendoscopy is a technique with proven success, but many more, novel endoscopic techniques are currently under investigation. In

  17. Spectrum of Endoscopic Findings in Nigerians with Dyspepsia ...

    African Journals Online (AJOL)

    There are differing information on the commonest endoscopic findings in patients with dyspepsia from Nigeria. Objective: The aim of this study was to determine the spectrum of endoscopic findings in patients with dyspepsia. Patients and Methods: This is a hospital-based prospective study carried out at the Endoscopy Unit ...

  18. Responsiveness of Endoscopic Indices of Disease Activity for Crohn's Disease

    NARCIS (Netherlands)

    Khanna, Reena; Zou, Guangyong; Stitt, Larry; Feagan, Brian G.; Sandborn, William J.; Rutgeerts, Paul; McDonald, John W. D.; Dubcenco, Elena; Fogel, Ronald; Panaccione, Remo; Jairath, Vipul; Nelson, Sigrid; Shackelton, Lisa M.; Huang, Bidan; Zhou, Qian; Robinson, Anne M.; Levesque, Barrett G.; D'Haens, Geert

    2017-01-01

    The Crohn's Disease Endoscopic Index of Severity (CDEIS) and the Simple Endoscopic Score for Crohn's Disease (SES-CD) are commonly used to assess Crohn's disease (CD) activity; however neither instrument is fully validated. We evaluated the responsiveness to change of the SES-CD and CDEIS using data

  19. Sonographic and Endoscopic Findings in Cocaine-Induced Ischemic Colitis

    DEFF Research Database (Denmark)

    Leth, Thomas; Wilkens, Rune; Bonderup, Ole Kristian

    2015-01-01

    Cocaine-induced ischemic colitis is a recognized entity. The diagnosis is based on clinical and endoscopic findings. However, diagnostic imaging is helpful in the evaluation of abdominal symptoms and prior studies have suggested specific sonographic findings in ischemic colitis. We report...... sonographic and endoscopic images along with abdominal computed tomography in a case of cocaine-induced ischemic colitis....

  20. How does a biopsy of endoscopically normal terminal ileum ...

    African Journals Online (AJOL)

    Background: Terminal ileum endoscopy and biopsy are the diagnostic tools of diseases attacking the ileum. However, abnormal histological findings can be found in endoscopically normal terminal ileum. Objective: This study was performed to evaluate the histopathological results of biopsies from endoscopically normal ...

  1. Endoscopic Treatment of Chyluria Using Povidone Iodine with ...

    African Journals Online (AJOL)

    Objective: To evaluate the safety and efficacy of povidone iodine with contrast agent as a sclerosant for the endoscopic treatment of chyluria. Patients and Methods: From December 1999 to October 2003, a total of 22 patients having chyluria were treated. After their baseline evaluation they were subjected to endoscopic ...

  2. Endoscopic Treatment of a Gastric Dieulafoy's Lesion | Ranketi ...

    African Journals Online (AJOL)

    Dieulafoy's lesion, a caliber persistent artery in the submucosa, is a rare but important cause of intermittent painless massive GI bleeding. Due to its intermittent nature, it can easily be missed and often requires multiple endoscopic evaluations. We present a case of one such patient with subsequent endoscopic findings and ...

  3. Bilateral retinal hemorrhage after endoscopic third ventriculostomy : iatrogenic Terson syndrome

    NARCIS (Netherlands)

    Hoving, Eelco W.; Rahmani, Mehrnoush; Los, Leonie I.; Renardel De Lavalette, Victor W.

    A serious ophthalmological complication of an endoscopic third ventriculostomy that created an iatrogenic Terson syndrome is described. A patient with an obstructive hydrocephalus was treated endoscopically, but due to the inadvertent use of a pressure bag during rinsing, in combination with a

  4. Transverse Anderson Localization in Disordered Glass Optical Fibers: A Review.

    Science.gov (United States)

    Mafi, Arash; Karbasi, Salman; Koch, Karl W; Hawkins, Thomas; Ballato, John

    2014-07-28

    Disordered optical fibers show novel waveguiding properties that can be used for various device applications, such as beam-multiplexed optical communications and endoscopic image transport. The strong transverse scattering from the transversely disordered optical fibers results in transversely confined beams that can freely propagate in the longitudinal direction, similar to conventional optical fibers, with the advantage that any point in the cross section of the fiber can be used for beam transport. For beam multiplexing and imaging applications, it is highly desirable to make the localized beam radius as small as possible. This requires large refractive index differences between the materials that define the random features in the disordered fiber. Here, disordered glass-air fibers are briefly reviewed, where randomly placed airholes in a glass matrix provide the sufficiently large refractive index difference of 0.5 for strong random transverse scattering. The main future challenge for the fabrication of an optimally disordered glass-air fibers is to increase the fill-fraction of airholes to nearly 50% for maximum beam confinement.

  5. A low-cost MRI compatible keyboard

    DEFF Research Database (Denmark)

    Jensen, Martin Snejbjerg; Heggli, Ole Adrian; Alves da Mota, Patricia

    2017-01-01

    Neuroimaging is a powerful tool to explore how and why humans engage in music. Magnetic resonance imaging (MRI) has allowed us to identify brain networks and regions implicated in a range of cognitive tasks including music perception and performance. However, MRI-scanners are noisy and cramped......, presenting a challenging environment for playing an instrument. Here, we present an MRI-compatible polyphonic keyboard with a materials cost of 850 $, designed and tested for safe use in 3T (three Tesla) MRI-scanners. We describe design considerations, and prior work in the field. In addition, we provide...

  6. Rate-Compatible Protograph LDPC Codes

    Science.gov (United States)

    Nguyen, Thuy V. (Inventor); Nosratinia, Aria (Inventor); Divsalar, Dariush (Inventor)

    2014-01-01

    Digital communication coding methods resulting in rate-compatible low density parity-check (LDPC) codes built from protographs. Described digital coding methods start with a desired code rate and a selection of the numbers of variable nodes and check nodes to be used in the protograph. Constraints are set to satisfy a linear minimum distance growth property for the protograph. All possible edges in the graph are searched for the minimum iterative decoding threshold and the protograph with the lowest iterative decoding threshold is selected. Protographs designed in this manner are used in decode and forward relay channels.

  7. Axial-Stereo 3-D Optical Metrology for Inner Profile of Pipes Using a Scanning Laser Endoscope.

    Science.gov (United States)

    Gong, Yuanzheng; Johnston, Richard S; Melville, C David; Seibel, Eric J

    As the rapid progress in the development of optoelectronic components and computational power, 3D optical metrology becomes more and more popular in manufacturing and quality control due to its flexibility and high speed. However, most of the optical metrology methods are limited to external surfaces. This paper proposed a new approach to measure tiny internal 3D surfaces with a scanning fiber endoscope and axial-stereo vision algorithm. A dense, accurate point cloud of internally machined threads was generated to compare with its corresponding X-ray 3D data as ground truth, and the quantification was analyzed by Iterative Closest Points algorithm.

  8. Outcome of endoscopic decompression of retrocalcaneal bursitis

    Directory of Open Access Journals (Sweden)

    Vamsi Kondreddi

    2012-01-01

    Full Text Available Background: Posterior heel pain due to retrocalcaneal bursitis, is a disabling condition that responds well to the conventional methods of treatment. Patients who do not respond to conservative treatment may require surgical intervention. This study evaluates the outcome of endoscopic decompression of retrocalcaneal bursitis, with resection of posterosuperior eminence of the calcaneum. Materials and Methods: This present study included 25 heels from 23 consecutive patients with posterior heel pain, who did not respond to conservative treatment and underwent endoscopic decompression of the retrocalcaneal bursae and excision of bony spurs. The functional outcome was evaluated by comparing the pre and postoperative American Orthopedic Foot and Ankle Society (AOFAS scores. The Maryland ankle and foot score was used postoperatively to assess the patient′s satisfaction at the one-year followup. Results: The University of Maryland scores of 25 heels were categorized as the nonparametric categories, and it was observed that 16 patients had an excellent outcome, six good, three fair and there were no poor results. The AOFAS scores averaged 57.92 ± 6.224 points preoperatively and 89.08 ± 5.267 points postoperatively (P < 0.001, at an average followup of 16.4 months. The 12 heels having noninsertional tendinosis on ultrasound had low AOFAS scores compared to 13 heels having retrocalcaneal bursitis alone. At one year followup, correlation for preoperative ultrasound assessment of tendoachilles degeneration versus postoperative Maryland score (Spearman correlation had shown a strong negative correlation. Conclusion: Endoscopic calcaneal resection is highly effective in patients with mild or no degeneration and yields cosmetically better results with fewer complications. Patients with degenerative changes in Achilles tendon had poorer outcomes in terms of subjective satisfaction.

  9. Limited Approach in Endoscopic Dacryocystorhinostomy of Pediatrics.

    Science.gov (United States)

    Hashemi, Seyyed Mostafa; Eshaghian, Afrooz

    2017-01-01

    Limited spatial nasal cavity in children, make pediatric dacryocystorhinostomy (DCR) a difficult surgical procedure. We apply a limited approach to pediatric DCR and follow them for their consequences. An experimental study was done in pediatric DCR with limited approach (age consent, with general anesthesia, with nasal endoscopic surgery, lacrimal bone is exposed and extruded. In contrast with routine procedure, ascending process of maxillary sinus reserve; and marsupialization and wide exposure to lacrimal sac was done only by lacrimal bone defect; and cannulation preserve with temporary silicone tube. Between 2006 and 2012, 16 pediatric DCR was done by a unique surgeon in 2 otorhinolaryngologic centers. Before surgery 14 (87.5%) had epiphora, 3 (18.8%) had eye discharge, and 3 (18.8%) had eye sticky eye. Two (12.5%) had history of facial trauma, and 10 (62.5%) had congenital nasolacrimal duct insufficiency. Five (31.3%) had history of dacryocystitis. Patients were followed for 17 ± 9 months. Silicone tube stayed for 4 ± 2.5 months. We could follow 7 patients and minimal improvement or need to revision surgery considered as technical failure. After surgery, 3 patients had no epiphora with complete improvement; 2 had very good improvement with confidence of the patients and parents; 2 cases had unsuccessful surgery in our patients, who needs to another surgery. One of them had several probing and surgery before our endoscopic DCR. Limited approach in endoscopic DCR of pediatrics can be done in noncomplicated patients, with minimal manipulation, more confidence, and acceptable results.

  10. [Endoscopic ventriculocisternostomy complications in 108 hydrocephalic patients].

    Science.gov (United States)

    Alonso-Fernández, Luis; Leyva-Mastrapa, Tania; deJongh-Cobo, Enrique; Díaz-Alvarez, Manuel; Quintana-Pajon, Ingrid; Osuna, Irene Barrios; Morera-Pérez, Maricela

    2015-01-01

    Several reports have been published in relation to complications, sometimes fatal, associated to endoscopic ventriculocisternostomy (EVC). The objective of this study was to determine the range of complications using this surgical technique in a series of 108 patients. A retrospective and descriptive study was performed on 108 hydrocephalic patients: 76 children and 32 adults. All of them presented various forms of obstructive hydrocephalus. In a total of 108 patients, 114 EVC were performed. The follow-up period ranged between 6 months and 10 years (mean 6.8 years). Age of patients ranged from 6 days to 75 years old (mean 18 years). Aqueductal stenosis was the most common aetiology, with 62 patients (57.4%). Significant complications occurred in 10 patients (9.2%). During the course of the study, the complication rate dropped significantly. No patient died because of the procedure (mortality 0%). We applied the Endoscopic Third Ventriculostomy Success Score (ETVSS) developed by Kulkarni and collaborators to our series to know if this score could be useful in predicting ETV results. Like all minimally-invasive techniques, there is a steep learning curve for EVC. Correct patient selection and surgeon experience (which means not only familiarity with endoscopic techniques but also the performance of a minimum number of surgeries per year) are very important to avoid complications. The ETV Success Score devised closely approximates the predicted probability of ETV success. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  11. [Pull percutaneous endoscopic gastrostomy: personal experience].

    Science.gov (United States)

    Geraci, G; Sciumè, C; Pisello, F; Li Volsi, F; Facella, T; Tinaglia, D; Modica, G

    2007-04-01

    To review the indications, complications, and outcomes of percutaneous endoscopic gastrostomy (PEG), that are placed routinely in patients unable to obtain adequate nutrition from oral feeding for swallowing disorders (neurological diseases, head and neck cancer, oesophageal cancer, psychological disorders). Retrospective review of patients referred for PEG placement from 2003 to 2005. Endoscopic Surgery in Section of General and Thoracic Surgery, Faculty of Medicine and Surgery, Palermo, Italy. A total of 50 patients, 11 women and 39 men, referred our Section for PEG placement. Indications for PEG placement included various neurologic impairment (82%), oesophageal non-operable cancer (6%), cardia non-operable cancer (4%), cerebrovascular accident (2%), anorexia (2%), pharyngeal esophageal obstruction (2%), head and neck cancer (2%). All patients received preoperative antibiotics as short-term profilaxis. 51 PEGs were positioned in 50 patients. No major complications were registered; 45 patients (90%) were alive at 1 year follow-up and no mortality procedure-related was registered. Percutaneous endoscopic gastrotomy removal had been performed on 2 patients as end-point of treatment, and 43 patients continued to have PEGs in use at 2006. Outpatients PEG placement using conscious sedation is a safe and effective method for providing enteral nutrition. This technique constitutes the gold standard treatment for enteral nutrition in patients with neurologic impairment or as prophylactic in patients affected by head and neck cancer who needs demolitive surgery. Patients should be carefully assessed, and discussion with the patient and their families should be held to determine that the patient is an appropriate candidate. The Authors feel prophylactic antibiotics lessened the incidence of cutaneous perigastrostomy infection.

  12. Ophthalmic complications of endoscopic sinus surgery

    Directory of Open Access Journals (Sweden)

    Malgorzata Seredyka-Burduk

    Full Text Available Abstract Introduction: The proximity of the paranasal sinuses to the orbit and its contents allows the occurence of injuries in both primary or revision surgery. The majority of orbital complications are minor. The major complications are seen in 0.01-2.25% and some of them can be serious, leading to permanent dysfunction. Objective: The aim of this study was to determine the risk and type of ophthalmic complications among patients operated due to a chronic rhinosinusitis. Methods: This is a retrospective study of 1658 patients who underwent endoscopic sinus surgery for chronic rhinosinusitis with or without polyps or mucocele. Surgeries were performed under general anesthesia in all cases and consisted of polyps' removal, followed by middle metal antrostomy, partial or complete ethmoidectomy, frontal recess surgery and sphenoid surgery if necessary. The ophthalmic complications were classified according to type, frequency and clinical findings. Results: In our material 32.68% of the patients required revision surgery and only 10.1% had been previously operated in our Department. Overall complications occurred in 11 patients (0.66%. Minor complications were observed in 5 patients (0.3% with the most frequent being periorbital ecchymosis with or without emphysema. Major complications were observed in one patient (0.06% and were related to a lacrimal duct injury. Severe complications occurred in 5 cases (0.3%, with 2 cases and referred to a retroorbital hematoma, optic nerve injury (2 cases and one case of extraocular muscle injury. Conclusions: Orbital complications of endoscopic nasal surgery are rare. The incidence of serious complications, causing permanent disabilities is less than 0.3%. The most important parameters responsible for complications are extension of the disease, previous endoscopic surgery and coexisting anticoagulant treatment.

  13. Endoscopic Endonasal Approach to Mesencephalic Cavernous Malformations.

    Science.gov (United States)

    He, Shi-Ming; Wang, Yuan; Zhao, Tian-Zhi; Zheng, Tao; Lv, Wen-Hai; Zhao, Lan-Fu; Chen, Long; Sterling, Cole; Qu, Yan; Gao, Guo-Dong

    2016-06-01

    Symptomatic cavernous malformations involving the brainstem are difficult to access by conventional approaches, which often require dramatic brain retraction to gain adequate operative corridor. Here, we present a successful endoscopic endonasal transclival approach for resection of a hemorrhagic, symptomatic mesencephalic cavernous malformation. A 20-year-old woman presented with acute onset of headache, nausea, and vomiting. Computed tomography scan revealed a ventral midbrain hemorrhage. On day 3 of admission, the patient developed left-sided hemiparesis, restriction of medial and lateral left-eye movements, and loss of left pupillary light reflex. Subsequent magnetic resonance imaging demonstrated an increase of the midbrain lesion to 1.2 cm × 1.7 cm. Diffusion tensor imaging showed compression and lateral displacement of the right corticospinal tract near the thalamus and cerebral peduncle. Given the patient's clinical presentation and the findings on imaging, we suspected a mesencephalic cavernous malformation. The patient underwent an endoscopic endonasal transclival resection of a ventral midline mesencephalon cavernous malformation. A dark red lesion was directly visualized under the endoscope. After a small cortiectomy, the pial and perforator vessels were dissected, and dark-brown blood was drained from the cavernoma cavity. Using a biopsy forceps and with careful attention to the cavernoma borders, the lesion was removed and hemostasis was achieved. Pathologic examination confirmed cavernous malformation. One week after the operation, magnetic resonance imaging demonstrated total resection of the lesion. A 3-month follow-up revealed improved neurologic symptoms with minimal surgical morbidity. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Endoscopic Removal of Foreign Bodies in Children

    Directory of Open Access Journals (Sweden)

    Chien-Heng Lin

    2007-09-01

    Full Text Available The ingestion of foreign bodies such as coins, fish bones, plastic toy parts, batteries, and needles is common in children. Although the majority of ingested foreign bodies pass through the gastrointestinal tract unaided, some children require either nonsurgical or surgical intervention. The medical records of children who presented to the pediatric emergency department of a single tertiary referral center between December 2001 and May 2006 were reviewed. A total of 87 patients underwent an endoscopic procedure because of suspected foreign body ingestion and foreign bodies were identified by endoscopy in 74 patients (85.1%. The mean age of these 74 patients was 3.4 years (range, 6 months to 13 years. The most common site of foreign body lodgment was the esophagus (n=38,51.4%; other sites included the stomach (n=33,44.6% and duodenum (n=3, 4.0%. The types of foreign bodies included coins (n=42, 56.8%, button batteries (n = 16, 21.6%, sharp objects (n = 9, 12.2%, chicken bones (n = 2, 2.7% and others (n=5, 6.7%. Only two foreign bodies (button batteries in the duodenum could not be removed successfully by endoscopy. Instead, they were moved into the intestine and then eliminated spontaneously the following day. There were no major complications caused by foreign body ingestion or endoscopic procedures. The outcome of all patients was uneventful without morbidity or mortality. In our experience, endoscopic removal of foreign bodies under general anesthesia is an effective and safe method in children; the method also prevents erosion and perforation of the gastrointestinal tract.

  15. Endoscopic treatment of Morel-Lavallee lesion.

    Science.gov (United States)

    Kim, Sunghoon

    2016-05-01

    Morel-Lavallee lesion is a closed degloving soft tissue injury in which subcutaneous tissue is torn from the underlying muscular fascia. The tear leads to venolymphatic leak, and concomitant adipose tissue necrosis from the force of the trauma causes swelling and possible infection at the site of injury. The traditional treatment for the lesion is surgical drainage and debridement. In this report, an endoscopic method is described, which achieves the goal of an open surgical debridement but minimizes surgical morbidity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Endoscopic Treatment of Studer's Orthotopic Neobladder Lithiasis.

    Science.gov (United States)

    Gil-Sousa, Diogo; Oliveira-Reis, Daniel; Cavadas, Vitor; Oliveira, Manuel; Soares, José; Fraga, Avelino

    2015-05-01

    Studer's neobladder lithiasis is a rare but important long term complication of this orthotopic bladder substitute technique. We report a case of a 45 year-old male patient, submitted to a radical cystoprostatectomy with a Studer's orthotopic neobladder 4 years before, presenting bad compliance to recommended urinary habits, increased production of mucus and high post voiding residue. CT scan and urethrocystography showed a distended pouch with 2 major sacculations with narrow communication and a stone in each sacculation. A minimally invasive endoscopic technique was successfully used in the treatment of the 2 small calculus.

  17. Endoscopic Treatment of Studer's Orthotopic Neobladder Lithiasis

    Directory of Open Access Journals (Sweden)

    Diogo Gil-Sousa

    2015-05-01

    Full Text Available Studer's neobladder lithiasis is a rare but important long term complication of this orthotopic bladder substitute technique. We report a case of a 45 year-old male patient, submitted to a radical cystoprostatectomy with a Studer's orthotopic neobladder 4 years before, presenting bad compliance to recommended urinary habits, increased production of mucus and high post voiding residue. CT scan and urethrocystography showed a distended pouch with 2 major sacculations with narrow communication and a stone in each sacculation. A minimally invasive endoscopic technique was successfully used in the treatment of the 2 small calculus.

  18. Contrast-enhanced harmonic endoscopic ultrasound

    DEFF Research Database (Denmark)

    Săftoiu, A; Dietrich, C F; Vilmann, P

    2012-01-01

    Second-generation intravenous blood-pool ultrasound contrast agents are increasingly used in endoscopic ultrasound (EUS) for characterization of microvascularization, differential diagnosis of benign and malignant focal lesions, and improving staging and guidance of therapeutic procedures. Although...... contrast-enhanced harmonic EUS based on a very low mechanical index (0.08 - 0.12). Quantification techniques based on dynamic contrast-enhanced ultrasound have been recommended for perfusion imaging and monitoring of anti-angiogenic treatment, mainly based on time-intensity curve analysis. Most...

  19. Pseudoasbestos bodies and fibers in bronchoalveolar lavage of refractory ceramic fiber users.

    Science.gov (United States)

    Dumortier, P; Broucke, I; De Vuyst, P

    2001-08-01

    Refractory ceramic fibers (RCF) are widely used to replace asbestos in applications requiring high heat resistance. Ferruginous bodies mimicking asbestos bodies (ABs) have been detected in the lungs of RCF production workers. This raises the question about their presence in other occupational groups and whether "typical ABs" still reflect past asbestos exposures in all settings. An AB counting by phase-contrast light microscopy and a screening test by analytical electron microscopy were systematically performed on all bronchoalveolar lavage fluids (BALF) submitted to our laboratory in 1992 through 1997 (n = 1,800). When RCF were detected in electron microscopy, the structures considered as "typical ABs" were marked under light microscopy and prepared for further chemical and structural analysis. Pseudo-ABs on RCF were detected in samples from nine subjects (0.5%). All of them had worked either as foundry workers, steel workers, or welders. In these subjects, alumino-silicate fibers compatible with RCF accounted for 42% of the core fibers analyzed, other nonasbestos fibers for 28%, and asbestos fibers for 30%. ABs thus remain a valid marker of asbestos retention but attention must be paid to a possible occurrence of pseudo-asbestos bodies on RCF and other nonasbestos fibers in end-users of refractory fibers.

  20. Laparoscopic caecal wedge resection with intraoperative endoscopic assistance.

    Science.gov (United States)

    Giavarini, Luisa; Boni, Luigi; Cortellezzi, Camillo Claudio; Segato, Sergio; Cassinotti, Elisa; Rausei, Stefano; Dionigi, Gianlorenzo; Rovera, Francesca; Marzorati, Alessandro; Spampatti, Sebastiano; Sambucci, Daniele; Dionigi, Renzo

    2013-01-01

    Cancer is a potential evolution of adenomatous polyps, that is why nowadays screening programs for colorectal cancer are widely diffused. Colonoscopy is the gold standard procedure for identifying and resecting polyps; however, for some polyps resection during colonoscopy is not possible. The aim of the present study is to identify a fast and safe procedure for endoscopically resecting unresectable polyps. Patients with endoscopically unresectable polyps were scheduled for laparoscopic wedge resection under colonoscopic assistance. From November 2010 to November 2012 we treated 15 patients with endoscopically unresectable adenomatous polyps. All patients underwent a laparoscopic caecal wedge resection with intraoperative endoscopic assistance. All procedures were completed without complications and in all cases complete resection of the polyps was achieved. Laparoscopic wedge caecal resection with intraoperative colonoscopy is a fast and safe procedure that can be performed for large polyps that could not be treated endoscopically. Copyright © 2013 Elsevier Ltd and Surgical Associates Ltd. All rights reserved.

  1. Endoscopic scoring of late gastrointestinal mucosal damage after adjuvant radiochemotherapy

    Science.gov (United States)

    Dabak, Resat; Uygur-Bayramicli, Oya; Gemici, Cengiz; Yavuzer, Dilek; Sargin, Mehmet; Yildirim, Mehmet

    2006-01-01

    AIM: To evaluate late effects of chemoradiation on gastrointestinal mucosa with an endoscopic scoring system and compare it to a clinical scoring system. METHODS: Twenty-four patients going to receive chemoradiation after gastric surgery underwent endoscopy four wk after surgery and one year after the chemoradiation finished. Upper gastrointestinal findings were recorded according to a system proposed by World Organisation for Digestive Endoscopy (OMED) and clinical scoring was done with RTOG-EORTC radiation morbidity scoring systems. RESULTS: There was no significant endoscopic difference in gastric and intestinal mucosa after chemoradiation (P > 0.05) and there was no association between endoscopic scores and clinical scores. Endoscopic changes were minimal. CONCLUSION: Late effects after chemoradiation in operated patients with gastric cancers can be evaluated with an endoscopic scoring system objectively and this system is superior to clinical scoring systems. PMID:16865788

  2. Robust feature tracking for endoscopic pose estimation and structure recovery

    Science.gov (United States)

    Speidel, S.; Krappe, S.; Röhl, S.; Bodenstedt, S.; Müller-Stich, B.; Dillmann, R.

    2013-03-01

    Minimally invasive surgery is a highly complex medical discipline with several difficulties for the surgeon. To alleviate these difficulties, augmented reality can be used for intraoperative assistance. For visualization, the endoscope pose must be known which can be acquired with a SLAM (Simultaneous Localization and Mapping) approach using the endoscopic images. In this paper we focus on feature tracking for SLAM in minimally invasive surgery. Robust feature tracking and minimization of false correspondences is crucial for localizing the endoscope. As sensory input we use a stereo endoscope and evaluate different feature types in a developed SLAM framework. The accuracy of the endoscope pose estimation is validated with synthetic and ex vivo data. Furthermore we test the approach with in vivo image sequences from da Vinci interventions.

  3. Endoscopic resection of advanced and laterally spreading duodenal papillary tumors.

    Science.gov (United States)

    Klein, Amir; Tutticci, Nicholas; Bourke, Michael J

    2016-03-01

    Historically, neoplasia of the duodenal papilla has been managed surgically, which may be associated with substantial morbidity and mortality. In the absence of invasive cancer, even lesions with extensive lateral duodenal wall involvement, or limited intraductal extension may be cured endoscopically with a superior safety profile. Endoscopic papillectomy is associated with greater risks of adverse events such as bleeding than resection elsewhere in the gastrointestinal tract. Additionally site-specific complications such as pancreatitis exist. A structured approach to lesion assessment, adherence to technical aspects of resection, endoscopic management of complications and post-resection surveillance is required. Advances have been made in all facets of endoscopic papillary resection since its introduction in the 1980s; extending the boundaries of endoscopic cure, optimizing outcomes and enhancing patient safety. These will be the focus of the present review. © 2015 Japan Gastroenterological Endoscopy Society.

  4. Surgical stress response: does endoscopic surgery confer an advantage?

    DEFF Research Database (Denmark)

    Kehlet, H

    1999-01-01

    "Open" surgical procedures are followed by profound changes in endocrine metabolic function and various host defense mechanisms, impaired pulmonary function, and hypoxemia. These physiologic changes are supposed to be involved in the pathogenesis of postoperative morbidity. Endoscopic surgery...... of postoperative pulmonary function and less hypoxemia with endoscopic operation. The slight modification of surgical stress responses by endoscopic surgery is in contrast to the common, though not universal, demonstration of less pain, shorter hospital stay, and less morbidity after endoscopic surgery....... In conclusion, endoscopic surgery has so far not been demonstrated to have important modifying effects on classic endocrine metabolic responses and only a slight inhibitory effect on various inflammatory responses, but with improved pulmonary function and less hypoxemia. More data are needed from major...

  5. Endoscopic management of difficult common bile duct stones

    Science.gov (United States)

    Trikudanathan, Guru; Navaneethan, Udayakumar; Parsi, Mansour A

    2013-01-01

    Endoscopy is widely accepted as the first treatment option in the management of bile duct stones. In this review we focus on the alternative endoscopic modalities for the management of difficult common bile duct stones. Most biliary stones can be removed with an extraction balloon, extraction basket or mechanical lithotripsy after endoscopic sphincterotomy. Endoscopic papillary balloon dilation with or without endoscopic sphincterotomy or mechanical lithotripsy has been shown to be effective for management of difficult to remove bile duct stones in selected patients. Ductal clearance can be safely achieved with peroral cholangioscopy guided laser or electrohydraulic lithotripsy in most cases where other endoscopic treatment modalities have failed. Biliary stenting may be an alternative treatment option for frail and elderly patients or those with serious co morbidities. PMID:23345939

  6. [Assessment of amylase and lipase levels following puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions].

    Science.gov (United States)

    Membrillo-Romero, Alejandro; Gonzalez-Lanzagorta, Rubén; Rascón-Martínez, Dulce María

    Puncture biopsy and fine needle aspiration guided by endoscopic ultrasound has been used as an effective technique and is quickly becoming the procedure of choice for diagnosis and staging in patients suspected of having pancreatic cancer. This procedure has replaced retrograde cholangiopancreatography and brush cytology due to its higher sensitivity for diagnosis, and lower risk of complications. To assess the levels of pancreatic enzymes amylase and lipase, after the puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions and the frequency of post-puncture acute pancreatitis. A longitudinal and descriptive study of consecutive cases was performed on outpatients submitted to puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions. Levels of pancreatic enzymes such as amylase and lipase were measured before and after the pancreatic puncture. Finally we documented post-puncture pancreatitis cases. A total of 100 patients who had been diagnosed with solid and cystic lesions were included in the study. Significant elevation was found at twice the reference value for lipase in 5 cases (5%) and for amylase in 2 cases (2%), none had clinical symptoms of acute pancreatitis. Eight (8%) of patients presented with mild nonspecific pain with no enzyme elevation compatible with pancreatitis. Pancreatic biopsy needle aspiration guided by endoscopic ultrasound was associated with a low rate of elevated pancreatic enzymes and there were no cases of post-puncture pancreatitis. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  7. Polymer Matrix Composite Material Oxygen Compatibility

    Science.gov (United States)

    Owens, Tom

    2001-01-01

    Carbon fiber/polymer matrix composite materials look promising as a material to construct liquid oxygen (LOX) tanks. Based on mechanical impact tests the risk will be greater than aluminum, however, the risk can probably be managed to an acceptable level. Proper tank design and operation can minimize risk. A risk assessment (hazard analysis) will be used to determine the overall acceptability for using polymer matrix composite materials.

  8. Photonic crystal fibers -

    DEFF Research Database (Denmark)

    Libori, Stig E. Barkou

    2002-01-01

    During this ph.d. work, attention has been focused on understanding and analyzing the modal behavior of micro-structured fibers. Micro-structured fibers are fibers with a complex dielectric toplogy, and offer a number of novel possibilities, compared to standard silica based optical fibers....... The thesis focuses on understanding the basic mechanisms controlling the modal properties of micro-structured fibers. One important sub-class of micro-structured fibers are fibers that guide light by index effects similar to those index effects that ensure guidance of light in standard optical fibers....... Such micro-structured fibers are the ones most often trated in literature concerning micro-structured fibers. These micro-structured fibers offer a whole range of novel wave guiding characteristics, including the possibility of fibers that guide only one mode irrespective of the frequency of light...

  9. Development of Recycling Compatible Pressure-Sensitive Adhesives and Coatings

    Energy Technology Data Exchange (ETDEWEB)

    Steven J. Severtson

    2010-02-15

    The objective of this project was the design of new water-based pressure-sensitive adhesive (PSA) products and coatings engineered for enhanced removal during the processing of recycled fiber. Research included the formulation, characterization, and performance measurements of new screenable coatings, testing of modified paper and board substrates and the design of test methods to characterize the inhibition of adhesive and coating fragmentation and relative removal efficiencies of developed formulations. This project was operated under the requirements that included commercially viable approaches be the focus, that findings be published in the open literature and that new strategies could not require changes in the methods and equipment used to produce PSA and PS labels or in the recycling process. The industrial partners benefited through the building of expertise in their company that they would not, and likely could not, have pursued if it had not been for the partnership. Results of research on water-based PSAs clearly identifies which PSA and paper facestock properties govern the fragmentation of the adhesive and provide multiple strategies for making (pressure-sensitive) PS labels for which the PSA is removed at very high efficiencies from recycling operations. The application of these results has led to the identification of several commercial products in Franklin International’s (industrial partner) product line that are recycling compatible. Several new formulations were also designed and are currently being scaled-up. Work on recycling compatible barrier coatings for corrugated containers examined the reinforcement of coatings using a small amount of exfoliated organically modified montmorillonite (OMMT). These OMMT/paraffin wax nanocomposites demonstrated significantly improved mechanical properties. Paraffin waxes containing clay were found to have significantly higher Young’s moduli and yield stress relative to the wax matrix, but the most

  10. Evaluation of the 3-dimensional endoscope in transsphenoidal surgery.

    Science.gov (United States)

    Barkhoudarian, Garni; Del Carmen Becerra Romero, Alicia; Laws, Edward R

    2013-09-01

    Three-dimensional (3-D) endoscopy is a recent addition to augment the transsphenoidal surgical approach for anterior skull-base and parasellar lesions. We describe our experience implementing this technology into regular surgical practice. Retrospective review of clinical factors and outcomes. All patients were analyzed who had endoscopic endonasal parasellar operations since the introduction of the 3-D endoscope to our practice. Over an 18-month period, 160 operations were performed using solely endoscopic techniques. Sixty-five of these were with the Visionsense VSII 3-D endoscope and 95 utilized 2-dimensional (2-D) high-definition (HD) Storz endoscopes. Intraoperative and postoperative findings were analyzed in a retrospective fashion. Comparing both groups, there was no significant difference in total or surgical operating room times comparing the 2-D HD and 3-D endoscopes (239 minutes vs 229 minutes, P = .47). Within disease-specific comparison, pituitary adenoma resection was significantly shorter utilizing the 3-D endoscope (surgical time 174 minutes vs 147 minutes, P = .03). These findings were independent of resident or fellow experience. There was no significant difference in the rate of complication, reoperation, tumor resection, or intraoperative cerebrospinal fluid leaks. Subjectively, the 3-D endoscope offered increased agility with 3-D techniques such as exposing the sphenoid rostrum, drilling sphenoidal septations, and identifying bony landmarks and suprasellar structures. The 3-D endoscope is a useful alternative to the 2-D HD endoscope for transnasal anterior skull-base surgery. Preliminary results suggest it is more efficient surgically and has a shorter learning curve. As 3-D technology and resolution improve, it should serve to be an invaluable tool for neuroendoscopy.

  11. A technical review of flexible endoscopic multitasking platforms.

    Science.gov (United States)

    Yeung, Baldwin Po Man; Gourlay, Terence

    2012-01-01

    Further development of advanced therapeutic endoscopic techniques and natural orifice translumenal endoscopic surgery (NOTES) requires a powerful flexible endoscopic multitasking platform. Medline search was performed to identify literature relating to flexible endoscopic multitasking platform from year 2004-2011 using keywords: Flexible endoscopic multitasking platform, NOTES, Instrumentation, Endoscopic robotic surgery, and specific names of various endoscopic multitasking platforms. Key articles from articles references were reviewed. Flexible multitasking platforms can be classified as either mechanical or robotic. Purely mechanical systems include the dual channel endoscope (DCE) (Olympus), R-Scope (Olympus), the EndoSamurai (Olympus), the ANUBIScope (Karl-Storz), Incisionless Operating Platform (IOP) (USGI), and DDES system (Boston Scientific). Robotic systems include the MASTER system (Nanyang University, Singapore) and the Viacath (Hansen Medical). The DCE, the R-Scope, the EndoSamurai and the ANUBIScope have integrated visual function and instrument manipulation function. The IOP and DDES systems rely on the conventional flexible endoscope for visualization, and instrument manipulation is integrated through the use of a flexible, often lockable, multichannel access device. The advantage of the access device concept is that it allows optics and instrument dissociation. Due to the anatomical constrains of the pharynx, systems are designed to have a diameter of less than 20 mm. All systems are controlled by traction cable system actuated either by hand or by robotic machinery. In a flexible system, this method of actuation inevitably leads to significant hysteresis. This problem will be accentuated with a long endoscope such as that required in performing colonic procedures. Systems often require multiple operators. To date, the DCE, the R-Scope, the IOP, and the Viacath system have data published relating to their application in human. Alternative forms of

  12. Use of industrial wireless endoscope in intrauterine artificial insemination in sheep

    Directory of Open Access Journals (Sweden)

    Gutierrez EF

    2017-08-01

    Full Text Available The aim of this study was to evaluate the use of an industrial wireless endoscope on the pregnancy rate of Hampshire Down sheep with intrauterine insemination. The work was carried out in a farm of the community Sullkataca Baja of the municipality of Laja, department of La Paz, Bolivia. The conditioning of an endoscopy equipment (Wifi Endoscope®, Teslong which had a portable and multifunctional Wi-Fi camera with fiber optic 8.5mm diameter, LED light and real-time video transmission at 720P. Also, 2 metal trocars (used in cattle were adapted to facilitate the entrance of the endoscopy and the insemination pipette. The estrus synchronization was performed in 10 nulliparas and 10 multiparas by means of intravaginal sponges with 60 mg of medroxyprogesterone acetate (Progespon®, Lab. Syntex Argentina for 14 days. A dose of 500 IU of eCG (Sergon®, Lab. Bioveta Czech Republic is applied to the removal of the sponges. At 52.31 ± 0.31 hours post removal of the sponges, artificial insemination fixed time (FTAI was performed with frozen semen in straws of 0.25cc with 40 million spermatozoa. During insemination, the values of 80% and 100% of uterine horn turgor were determined for the group of pluriparas and nulliparas respectively. The pregnancy diagnosis was performed at 50 days post insemination using ultrasound transrectal (EMP 820 vet plus®, Emperor China. Gestation rates were 60% for lambs and 70% for ewes (P≥0.05. In conclusion, the industrial wireless endoscope is an economical, versatile equipment and can be used efficiently to perform intrauterine IATF with frozen semen in sheep.

  13. Electromagnetic Compatibility of Matrix Converter System

    Directory of Open Access Journals (Sweden)

    S. Fligl

    2006-12-01

    Full Text Available The presented paper deals with matrix converters pulse width modulation strategies design with emphasis on the electromagnetic compatibility. Matrix converters provide an all-silicon solution to the problem of converting AC power from one frequency to another, offering almost all the features required of an ideal static frequency changer. They possess many advantages compared to the conventional voltage or current source inverters. A matrix converter does not require energy storage components as a bulky capacitor or an inductance in the DC-link, and enables the bi-directional power flow between the power supply and load. The most of the contemporary modulation strategies are able to provide practically sinusoidal waveforms of the input and output currents with negligible low order harmonics, and to control the input displacement factor. The perspective of matrix converters regarding EMC in comparison with other types of converters is brightly evident because it is no need to use any equipment for power factor correction and current and voltage harmonics reduction. Such converter with proper control is properly compatible both with the supply mains and with the supplied load. A special digital control system was developed for the realized experimental test bed which makes it possible to achieve greater throughput of the digital control system and its variability.

  14. Is religious education compatible with science education?

    Science.gov (United States)

    Mahner, Martin; Bunge, Mario

    1996-04-01

    This paper tackles a highly controversial issue: the problem of the compatibility of science and religion, and its bearing on science and religious education respectively. We challenge the popular view that science and religion are compatible or even complementary. In order to do so, we give a brief characterization of our conceptions of science and religion. Conspicuous differences at the doctrinal, metaphysical, methodological and attitudinal level are noted. Regarding these aspects, closer examination reveals that science and religion are not only different but in fact incompatible. Some consequences of our analysis for education as well as for education policy are explored. We submit that a religious education, particularly at an early age, is an obstacle to the development of a scientific mentality. For this and other reasons, religious education should be kept away from public schools and universities. Instead of promoting a religious world view, we should teach our children what science knows about religion, i.e., how science explains the existence of religion in historical, biological, psychological and sociological terms.

  15. Electromagnetic compatibility management for fast diagnostic design

    Science.gov (United States)

    Raimbourg, J.

    2004-10-01

    This article presents an overview of electromagnetic compatibility (EMC) management for fast diagnostic design. We will present and detail the classical approach in EMC. This approach can be successfully applied for installations where a single engineering entity has the authority to prescribe and enforce a certain compatibility level. Most of the time, strict application of generic standards is required for fast diagnostics. Nethertheless, the pulse perturbation must be synchronized to the fast diagnostic operation. Some "traditional" techniques, such as star-earthing and bonding cable screens at one end, have been shown to be inadequate for fast diagnostic design. Our laser facility, the LIL, will be able to focus up to 60 kJ into a volume of less than 1 mm3. We have to evaluate the electromagnetic pulse (EMP) where diagnostics, cables, and oscilloscopes will be installed. We performed electromagnetic measurements inside and outside the OMEGA target chamber. The electromagnetic pulse generated by the target chamber contains very high frequency components above 1 GHz. The electric field is around a few kV/m outside and goes up to 20 kV/m inside the target. We designed a specific electromagnetic probe for pulse measurement with a rise time down to 100 ps. An ultrashort rise time EMP bench test was built to test apparatus before installation around a target chamber. It produces an electric field higher than 5 kV/m with a rise time under 100 ps.

  16. Integrated environmentally compatible soldering technologies. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Hosking, F.M.; Frear, D.R.; Iman, R.L.; Keicher, D.M.; Lopez, E.P.; Peebles, H.C.; Sorensen, N.R.; Vianco, P.T.

    1994-05-01

    Chemical fluxes are typically used during conventional electronic soldering to enhance solder wettability. Most fluxes contain very reactive, hazardous constituents that require special storage and handling. Corrosive flux residues that remain on soldered parts can severely degrade product reliability. The residues are removed with chlorofluorocarbon (CFC), hydrochlorofluorocarbon (HCFC), or other hazardous solvents that contribute to ozone depletion, release volatile organic compounds into the atmosphere, or add to the solvent waste stream. Alternative materials and processes that offer the potential for the reduction or elimination of cleaning are being developed to address these environmental issues. Timing of the effort is critical, since the targeted chemicals will soon be heavily taxed or banned. DOE`s Office of Environmental Restoration and Waste Management (DOE/EM) has supported Sandia National Laboratories` Environmentally Conscious Manufacturing Integrated Demonstration (ECMID). Part of the ECM program involves the integration of several environmentally compatible soldering technologies for assembling electronics devices. Fluxless or {open_quotes}low-residue/no clean{close_quotes} soldering technologies (conventional and ablative laser processing, controlled atmospheres, ultrasonic tinning, protective coatings, and environmentally compatible fluxes) have been demonstrated at Sandia (SNL/NM), the University of California at Berkeley, and Allied Signal Aerospace-Kansas City Division (AS-KCD). The university demonstrations were directed under the guidance of Sandia staff. Results of the FY93 Soldering ID are presented in this report.

  17. Photonic Bandgap Fibers

    DEFF Research Database (Denmark)

    Barkou, Stig Eigil; Broeng, Jes; Bjarklev, Anders Overgaard

    1999-01-01

    Photonic bandgap fibers are describes using a new Kagomé cladding structure. These fibers may potentially guide light in low-index regions. Such fibers offer new dispersion properties, and large design flexibility.......Photonic bandgap fibers are describes using a new Kagomé cladding structure. These fibers may potentially guide light in low-index regions. Such fibers offer new dispersion properties, and large design flexibility....

  18. Is in vivo analysis of urinary stone composition feasible? Evaluation of an experimental setup of a Raman system coupled to commercial lithotripsy laser fibers.

    Science.gov (United States)

    Miernik, Arkadiusz; Eilers, Yvan; Nuese, Christoph; Bolwien, Carsten; Lambrecht, Armin; Hesse, Albrecht; Rassweiler, Jens J; Schlager, Daniel; Wilhelm, Konrad; Wetterauer, Ulrich; Schoenthaler, Martin

    2015-10-01

    Raman spectroscopy allows immediate analysis of stone composition. In vivo stone analysis during endoscopic treatment may offer advantages concerning surgical strategy and metaphylaxis. Urinary stone components were evaluated utilizing an experimental setup of a Raman system coupled to commercial laser fibers. Samples of paracetamol (acetaminophen) and human urinary stones with known Raman spectra were analyzed using an experimental Raman system coupled to common commercial lithotripsy laser fibers (200 and 940 µm). Two different excitation lasers were used at wavelengths of 532 and 785 nm. Numerical aperture of the fibers, proportion of reflected light reaching the CCD chip, and integration times were calculated. Mathematical signal correction was performed. Both the laser beam profile and the quality of light reflected by the specimens were impaired significantly when used with commercial fibers. Acquired spectra could no longer be assigned to a specific stone composition. Subsequent measurements revealed a strong intrinsic fluorescence of the fibers and poor light acquisition properties leading to a significant decrease in the Raman signal in comparison with a free-beam setup. This was true for both investigated fiber diameters and both wavelengths. Microscopic examination showed highly irregular fiber tip surfaces (both new and used fibers). Our results propose that laser excitation and light acquisition properties of commercial lithotripsy fibers impair detectable Raman signals significantly in a fiber-coupled setting. This study provides essential physical and technological information for the development of an advanced fiber-coupled system able to be used for immediate stone analysis during endoscopic stone therapy.

  19. The effect of modified ijuk fibers to crystallinity of polypropylene composite

    Science.gov (United States)

    Prabowo, I.; Nur Pratama, J.; Chalid, M.

    2017-07-01

    Nowadays, plastics becomes concern associated with its degradation and environmental issues. It has led studies to develop an environmental-friendly material. To minimize the impact of those problems, recently the usage of natural fibers as a filler are introduced because of biodegradability and availability. The promising natural fiber is “ijuk” fiber from Arenga pinnata plant as a filler and polypropylene (PP) polymer as a matrix. Unfortunately, the natural fibers and polymers have the different properties on which polymers are polar while natural fibers are non-polar so that reducing the compatibility and resulting the poor crystallinity. To enhance the compatibility and crystallinity, ijuk fibers were prepared by multistage treatments including alkalinization with 5 and 10% sodium hydroxide (NaOH), oxidation with 3 and 6% sodium hypochlorite (NaClO) and hydrolysis with 20% sulphuric acid (H2SO4) in sequences. The purposes of multistage treatments are to remove the components such as lignin, wax, hemicellulose, to cause an oxidative fragmentation of remaining lignin and to annihilate the amorphous parts respectively. Fourier-Transform Infrared (FTIR) confirms the compatibility meanwhile Differential Scanning Calorimetry (DSC) reveals the crystallinity and Scanning Electron Microscope (SEM) displays surface morphology of polypropylene. The experiments were revealing that the effects of “ijuk” fibers by the multistage treatments of 5 and 10% NaOH resulting the crystallinity of polypropylene around 31.2 and 27.64% respectively compared to the crystallinity before adding the “ijuk” fibers for 16.8%. It indicates that the entire treatments increasing the compatibility and crystallinity of polypropylene. In addition, the use of 5% NaOH offers the better crystallinity than non-treated polypropylene. The experiments conclude that by adding alkalinized “ijuk” fibers of multistage treatments can increase the compatibility and crystallinity of polypropylene.

  20. High Numerical Aperture Silica Core Fibers For Biosensor Applications

    Science.gov (United States)

    Skutnik, B. J.; Brucker, C. T.; Clarkin, J. P.

    1988-06-01

    The whole field of biosensing has been enhanced by the development of optical fibers(l). They provide a means of activating the sensors and of carrying the sensor's signal back to the detector. The small dimensions and flexibility of the fibers allow the development of miniaturized sensor packages capable of introduction into a patient's vascular system. Several in vitro systems are already competing in high risk operations with standard laboratory procedures to provide more timely and accurate analysis of the patient's condition. During the next decade real time sensing in vivo together with various endoscopic and developing laser surgery techniques will provide doctors and patients with many new and delicate alternative procedures to common surgery. Not only will trauma be minimized, but with better and quicker knowledge of the patient's blood gas levels and other body conditions, doctors will be able to efficiently correct for unforeseen difficulties while controlling the known problems effectively. To achieve these wonders extremely small sensing areas will be available so that the sensor systems must be highly efficient. The optical fibers must activate all or at least most of the sensor's area and must be able to gather as much of the return signal from the sensor as possible. This places some strong requirements on the optical properties of the fibers. The need for flexible, yet sturdy, devices places requirements on the mechanical properties of the fibers. For the preferred silica based fibers, the fact that body fluids are primarily water place additional demands on the fibers' mechanical properties. Obviously the sensing system being in contact or close proximity with the body or its fluids must satisfy certain biocompatibility and sterilization requirements. This paper further describes these requirements and presents details about a new optical fiber which meets these requirements and provides some additional very useful properties. This new fiber which

  1. Rare Endoscopic Manifestation of Pancreatic Adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Haritha Chelimilla

    2012-07-01

    Full Text Available Gastric ulcer secondary to direct invasion from pancreatic adenocarcinoma is rare. Metastases to the stomach have been commonly reported with melanoma and with primary tumors of the breast, lung, ovary, liver, colon and testis. We report a patient who presented with epigastric pain and in whom subsequently upper endoscopy showed a malignant gastric ulcer secondary to direct invasion from pancreatic adenocarcinoma of the body. An 81-year-old female presented to our hospital with epigastric pain and subsequently underwent endoscopy with endoscopic ultrasound for evaluation of a pancreatic body mass. She had a large gastric ulcer in the fundus which was in direct continuity with the pancreatic mass. Pathology from biopsy of the ulcer revealed invasive well-to-moderately-differentiated adenocarcinoma, and immunohistochemical stains were strongly positive for CA19-9, CK7, CK19 and carcinoembryonic antigen. These findings were consistent with a histopathological diagnosis of metastatic carcinoma of the pancreas. Patients with gastrointestinal metastases usually have advanced malignancy with poor prognosis. Endoscopic evaluation with adequate biopsies should be performed for symptomatic patients.

  2. Laser Endoscopic Microsurgery of Laryngeal Cancers

    Directory of Open Access Journals (Sweden)

    Moustapha, Sereme

    2014-01-01

    Full Text Available Introduction The aim of our study is to present our experience in treating laryngeal cancers with endoscopic CO2 laser surgery. Materials and Methods This retrospective study was conducted from January 2008 to December 2012 at Antoine Lacassagne Center of Nice. The functional and oncologic results of this surgical technique were analyzed and discussed. Results The average length of hospital stay was 2.5 days. Phonatory results were considered excellent in 75% of our patients who maintained satisfactory phone communication skills after their interventions. Chronic hoarseness was the most common reason for bilateral or extended cordectomies. On the oncologic basis, histologic exam showed 90% of our margins were normal. The clinical control showed excellent laryngeal preservation in 94.23%. In 5 years, the overall survival was estimated at 96.15%. Conclusion This study shows the benefit of the laser endoscopic microsurgery for the preservation of laryngeal functions and the local histologic control, essentially for early stage laryngeal cancers.

  3. PREOPERATIVE ENDOSCOPIC MARKING OF UNPALPABLE COLONIC TUMORS

    Directory of Open Access Journals (Sweden)

    A. L. Goncharov

    2013-01-01

    Full Text Available The identification of small colon lesions is one of the major problems in laparoscopic colonic resection.Research objective: to develop a technique of visualization of small tumors of a colon by preoperative endoscopic marking of a tumor.Materials and methods. In one day prior to operation to the patient after bowel preparation the colonoscopy is carried out. In the planned point near tumor on antimesentery edge the submucous infiltration of marking solution (Micky Sharpz blue tattoo pigment, UK is made. The volume of entered solution of 1–3 ml. In only 5 months of use of a technique preoperative marking to 14 patients with small (the size of 1–3 cm malignant tumors of the left colon is performed.Results. The tattoo mark was well visualized by during operation at 13 of 14 patients. In all cases we recorded no complications. Time of operation with preoperative marking averaged 108 min, that is significantly less in comparison with average time of operation with an intra-operative colonoscopy – 155 min (р < 0.001.Conclusions. The first experience of preoperative endoscopic marking of non palpable small tumors of a colon is encouraging. Performance of a technique wasn't accompanied by complications and allowed to reduce significantly time of operation and to simplify conditions of performance of operation.

  4. [Endoscopic treatment of vesicoureteral reflux in children].

    Science.gov (United States)

    Burkin, A G; Iatsyk, S P; Sharkov, S M; Rusakov, A A; Tin, I F

    2014-01-01

    The one of the most common defects of the ureter-vesical segment in children is the condition, leading to a disorder of obturative function of this segment. Complications of vesicoureteral reflux include continuously recurrent pyelonephritis, reflux nephropathy. In this regard, the choice of the optimal treatment strategy based on minimal invasion is considered as one of the priorities of pediatric urology. The article presents the data obtained during the treatment of VUR in children of different ages in the Clinic of Reproductive Health FSBSI SCCH. A comparative evaluation of the results of endoscopic correction of vesicoureteral reflux depending on the kind of the bulking agent was performed. It was found that the use of endocorrection of reflux is highly effective surgical procedure, with the high number of positive results against the background of use of bulking agent "vantris". The study discriminates a group of patients with vesicoureteral reflux, intractable for endoscopic correction with cystoscopically normal structure of the orifices that allows to refer this method to the initial stage of treatment of the disease.

  5. Posterior endoscopic discectomy: Results in 300 patients

    Directory of Open Access Journals (Sweden)

    Mohinder Kaushal

    2012-01-01

    Full Text Available Background: Posterior endoscopic discectomy is an established method for treatment of lumbar disc herniation. Many studies have not been reported in literature for lumbar discectomy by Destandau Endospine System. We report a series of 300 patients operated for lumbar dissectomy by Destandau Endospine system. Materials and Methods: A total of 300 patients suffering from lumbar disc herniations were operated between January 2002 and December 2008. All patients were operated as day care procedure. Technique comprised localization of symptomatic level followed by insertion of an endospine system devise through a 15 mm skin and fascial incision. Endoscopic discectomy is then carried out by conventional micro disc surgery instruments by minimal invasive route. The results were evaluated by Macnab′s criteria after a minimum followup of 12 months and maximum up to 24 months. Results: Based on modified Macnab′s criteria, 90% patients had excellent to good, 8% had fair, and 2% had poor results. The complications observed were discitis and dural tear in five patients each and nerve root injury in two patients. 90% patients were able to return to light and sedentary work with an average delay of 3 weeks and normal physical activities after 2 months. Conclusion: Edoscopic discectomy provides a safe and minimal access corridor for lumbar discectomy. The technique also allows early postoperative mobilization and faster return to work.

  6. Endoscopic Management of Primary Sclerosing Cholangitis.

    Science.gov (United States)

    Barkin, Jodie A; Levy, Cynthia; Souto, Enrico O

    Primary sclerosing cholangitis (PSC) remains a rare but potentially devastating chronic, cholestatic liver disease. PSC causes obstruction of intra- and/or extra-hepatic bile ducts by inflammation and fibrosis, leading to biliary obstruction, cirrhosis and portal hypertension with all associated sequelae. The most dreaded consequence of PSC is cholangiocarcinoma, occurring in 10-20% of patients with PSC, and with population-based estimates of a 398-fold increased risk of cholangiocarcinoma in patients with PSC compared to the general population. We use the 4-D approach to endoscopic evaluation and management of PSC based on currently available evidence. After laboratory testing with liver chemistries and high-quality cross-sectional imaging with MRCP, the first D is Dominant stricture diagnosis and evaluation. Second, Dilation of strictures found during ERCP is performed using balloon dilation to as many segments as possible. Third, Dysplasia and cholangiocarcinoma diagnosis is performed by separated brushings for conventional cytology and fluorescence in situ hybridization (FISH), and consideration for direct cholangioscopy with SpyGlass™. Fourt and finally, Dosing of antibiotics is critical to prevent peri-procedural cholangitis. The aim of this review article is to explore endoscopic tools and techniques for the diagnosis and management of PSC and provide a practical approach for clinicians.

  7. Endoscopic management of complications of chronic pancreatitis.

    Science.gov (United States)

    Dumonceau, Jean-Marc; Macias-Gomez, Carlos

    2013-11-14

    Pseudocysts and biliary obstructions will affect approximately one third of patients with chronic pancreatitis (CP). For CP-related, uncomplicated, pancreatic pseudocysts (PPC), endoscopy is the first-choice therapeutic option. Recent advances have focused on endosonography-guided PPC transmural drainage, which tends to replace the conventional, duodenoscope-based coma immediately approach. Ancillary material is being tested to facilitate the endosonography-guided procedure. In this review, the most adequate techniques depending on PPC characteristics are presented along with supporting evidence. For CP-related biliary obstructions, endoscopy and surgery are valid therapeutic options. Patient co-morbidities (e.g., portal cavernoma) and expected patient compliance to repeat endoscopic procedures are important factors when selecting the most adapted option. Malignancy should be reasonably ruled out before embarking on the endoscopic treatment of presumed CP-related biliary strictures. In endoscopy, the gold standard technique consists of placing simultaneous, multiple, side-by-side, plastic stents for a one-year period. Fully covered self-expandable metal stents are challenging this method and have provided 50% mid-term success.

  8. Endoscopic Third Ventriculostomy in Previously Shunted Children

    Directory of Open Access Journals (Sweden)

    Eva Brichtova

    2013-01-01

    Full Text Available Endoscopic third ventriculostomy (ETV is a routine and safe procedure for therapy of obstructive hydrocephalus. The aim of our study is to evaluate ETV success rate in therapy of obstructive hydrocephalus in pediatric patients formerly treated by ventriculoperitoneal (V-P shunt implantation. From 2001 till 2011, ETV was performed in 42 patients with former V-P drainage implantation. In all patients, the obstruction in aqueduct or outflow parts of the fourth ventricle was proved by MRI. During the surgery, V-P shunt was clipped and ETV was performed. In case of favourable clinical state and MRI functional stoma, the V-P shunt has been removed 3 months after ETV. These patients with V-P shunt possible removing were evaluated as successful. In our group of 42 patients we were successful in 29 patients (69%. There were two serious complications (4.7%—one patient died 2.5 years and one patient died 1 year after surgery in consequence of delayed ETV failure. ETV is the method of choice in obstructive hydrocephalus even in patients with former V-P shunt implantation. In case of acute or scheduled V-P shunt surgical revision, MRI is feasible, and if ventricular system obstruction is diagnosed, the hydrocephalus may be solved endoscopically.

  9. Endoscopic vs. tactile evaluation of subgingival calculus.

    Science.gov (United States)

    Osborn, Joy B; Lenton, Patricia A; Lunos, Scott A; Blue, Christine M

    2014-08-01

    Endoscopic technology has been developed to facilitate imagery for use during diagnostic and therapeutic phases of periodontal care. The purpose of this study was to compare the level of subgingival calculus detection using a periodontal endoscope with that of conventional tactile explorer in periodontitis subjects. A convenience sample of 26 subjects with moderate periodontitis in at least 2 quadrants was recruited from the University of Minnesota School of Dentistry to undergo quadrant scaling and root planing. One quadrant from each subject was randomized for tactile calculus detection alone and the other quadrant for tactile detection plus the Perioscope ™ (Perioscopy Inc., Oakland, Cali). A calculus index on a 0 to 3 score was performed at baseline and at 2 post-scaling and root planing visits. Sites where calculus was detected at visit 1 were retreated. T-tests were used to determine within-subject differences between Perioscope™ and tactile measures, and changes in measures between visits. Significantly more calculus was detected using the Perioscope™ vs. tactile explorer for all 3 subject visits (pcalculus detection from baseline to visit 1 were statistically significant for both the Perioscope™ and tactile quadrants (pcalculus detection from visit 1 to visit 2 was only significant for the Perioscope™ quadrant (pcalculus at this visit. It was concluded that the addition of a visual component to calculus detection via the Perioscope™ was most helpful in the re-evaluation phase of periodontal therapy. Copyright © 2014 The American Dental Hygienists’ Association.

  10. [Conversional and endoscopic procedures following bariatric surgery].

    Science.gov (United States)

    Zorron, R; Bothe, C; Junghans, T; Pratschke, J; Benzing, C; Krenzien, F

    2016-10-01

    The Roux-en-Y gastric bypass (RYGB) is the therapy of choice in bariatric surgery. Sleeve gastrectomy and gastric banding are showing higher rates of treatment failure, reducing obesity-associated morbidity and body weight insufficiently. Moreover, gastroesophageal reflux disease (GERD) can occur refractory to medication. Therefore, a laparoscopic conversion to RYGB can be reasonable as long as specific conditions are fulfilled.Endoscopic procedures are currently being applied to revise bariatric procedures. Therapy failure following RYGB occurs in up to 20 % of cases. Transoral outlet reduction is the minimally invasive method of choice to reduce gastrojejunal anastomosis of the alimentary limb. The diameter of a gastric sleeve can be unwantedly enlarged as well; that can be reduced by placement of a longitudinal full-thickness suture.Severe hypoglycemic episodes can be present in patients following RYGB. Hypoglycemic episodes have to be diagnosed first and can be treated conventionally. Alternatively, a laparoscopic approach according to Branco-Zorron can be used for non-responders. Hypoglycemic episodes can thus be prevented and body weight reduction can be assured.Conversional and endoscopic procedures can be used in patients with treatment failure following bariatric surgery. Note that non-invasive approaches should have been applied intensively before a revisional procedure is performed.

  11. Probe alignment and design issues of microelectromechanical system based optical coherence tomography endoscopic imaging.

    Science.gov (United States)

    Duan, Can; Sun, Jingjing; Samuelson, Sean; Xie, Huikai

    2013-09-10

    Endoscopic optical coherence tomography (OCT) imaging has been demonstrated using microelectromechanical system (MEMS) technology by several research groups. The focus of this work is to study how the OCT imaging performance is affected by the radius of curvature of MEMS mirrors as well as the optical alignment accuracy inside small imaging probes. The goal of this study is to provide guidance for assembly tolerance and design optimization of OCT endoscopic probes. Gaussian beam propagation is used for theoretical analysis which is confirmed by optical simulation and verified experimentally with a time-domain OCT system as well. It has been found that the OCT imaging is very sensitive to the distance from the fiber end to the gradient-index (GRIN) lens, which needs to be controlled within 0.1 mm to achieve working distance (WD) longer than 3.5 mm and lateral resolution around 25 μm. The impact on image quality of the MEMS mirror is negligible if the radius of curvature of the mirror surface is greater than 200 mm. In addition, we studied the astigmatism introduced by cylindrical plastic tubing; the maximum astigmatism ratio is 1.1 when the WD is around 2.5 mm.

  12. Wide-field flexible endoscope for simultaneous color and NIR fluorescence image acquisition during surveillance colonoscopy

    Science.gov (United States)

    García-Allende, P. Beatriz; Nagengast, Wouter B.; Glatz, Jürgen; Ntziachristos, Vasilis

    2013-03-01

    Colorectal cancer (CRC) is the third most common form of cancer and, despite recent declines in both incidence and mortality, it still remains the second leading cause of cancer-related deaths in the western world. Colonoscopy is the standard for detection and removal of premalignant lesions to prevent CRC. The major challenges that physicians face during surveillance colonoscopy are the high adenoma miss-rates and the lack of functional information to facilitate decision-making concerning which lesions to remove. Targeted imaging with NIR fluorescence would address these limitations. Tissue penetration is increased in the NIR range while the combination with targeted NIR fluorescent agents provides molecularly specific detection of cancer cells, i.e. a red-flag detection strategy that allows tumor imaging with optimal sensitivity and specificity. The development of a flexible endoscopic fluorescence imaging method that can be integrated with standard medical endoscopes and facilitates the clinical use of this potential is described in this work. A semi-disposable coherent fiber optic imaging bundle that is traditionally employed in the exploration of biliary and pancreatic ducts is proposed, since it is long and thin enough to be guided through the working channel of a traditional video colonoscope allowing visualization of proximal lesions in the colon. A custom developed zoom system magnifies the image of the proximal end of the imaging bundle to fill the dimensions of two cameras operating in parallel providing the simultaneous color and fluorescence video acquisition.

  13. Routine colonic endoscopic evaluation following resolution of acute diverticulitis: Is it necessary?

    Science.gov (United States)

    Agarwal, Amit K; Karanjawala, Burzeen E; Maykel, Justin A; Johnson, Eric K; Steele, Scott R

    2014-01-01

    Diverticular disease incidence is increasing up to 65% by age 85 in industrialized nations, low fiber diets, and in younger and obese patients. Twenty-five percent of patients with diverticulosis will develop acute diverticulitis. This imposes a significant burden on healthcare systems, resulting in greater than 300000 admissions per year with an estimated annual cost of $3 billion USD. Abdominal computed tomography (CT) is the diagnostic study of choice, with a sensitivity and specificity greater than 95%. Unfortunately, similar CT findings can be present in colonic neoplasia, especially when perforated or inflamed. This prompted professional societies such as the American Society of Colon Rectal Surgeons to recommend patients undergo routine colonoscopy after an episode of acute diverticulitis to rule out malignancy. Yet, the data supporting routine colonoscopy after acute diverticulitis is sparse and based small cohort studies utilizing outdated technology. While any patient with an indication for a colonoscopy should undergo appropriate endoscopic evaluation, in the era of widespread use of high-resolution computed tomography, routine colonic endoscopic evaluation following resolution of acute uncomplicated diverticulitis poses additional costs, comes with inherent risks, and may require further study. In this manuscript, we review the current data related to this recommendation. PMID:25253951

  14. Compact, transmissive two-dimensional spatial disperser design with application in simultaneous endoscopic imaging and laser microsurgery.

    Science.gov (United States)

    Metz, Philipp; Adam, Jost; Gerken, Martina; Jalali, Bahram

    2014-01-20

    Minimally invasive surgery procedures benefit from a reduced size of endoscopic devices. A prospective path to implement miniaturized endoscopy is single optical-fiber-based spectrally encoded imaging. While simultaneous spectrally encoded inertial-scan-free imaging and laser microsurgery have been successfully demonstrated in a large table setup, a highly miniaturized optical design would promote the development of multipurpose endoscope heads. This paper presents a highly scalable, entirely transmissive axial design for a spectral 2D spatial disperser. The proposed design employs a grating prism and a virtual imaged phased array (VIPA). Based on semi-analytical device modeling, we performed a systematic parameter analysis to assess the spectral disperser's manufacturability and to obtain an optimum application-specific design. We found that, in particular, a low grating period combined with a high optical input bandwidth and low VIPA tilt showed favorable results in terms of a high spatial resolution, a small device diameter, and a large field of view. Our calculations reveal that a reasonable imaging performance can be achieved with system diameters of below 5 mm, which renders the proposed 2D spatial disperser design highly suitable for use in future endoscope heads that combine mechanical-scan-free imaging and laser microsurgery.

  15. Effects of wood fiber surface chemistry on strength of wood-plastic composites

    Science.gov (United States)

    Migneault, Sébastien; Koubaa, Ahmed; Perré, Patrick; Riedl, Bernard

    2015-07-01

    Because wood-plastic composites (WPC) strength relies on fiber-matrix interaction at fiber surface, it is likely that fiber surface chemistry plays an important role in WPC strength development. The objective of the present study is to investigate the relationships between fiber surface chemical characteristics and WPC mechanical properties. Different fibers were selected and characterized for surface chemical characteristics using X-ray photoelectron spectroscopy (XPS) and infrared spectroscopy (FTIR). WPC samples were manufactured at 40% fiber content and with six different fibers. High density polyethylene was used as matrix and maleated polyethylene (MAPE) was used as compatibility agent. WPC samples were tested for mechanical properties and fiber-matrix interface was observed with scanning electron microscope. It was found WPC strength decreases as the amount of unoxidized carbon (assigned to lignin and extractives) measured with XPS on fiber surface increases. In the opposite case, WPC strength increases with increasing level of oxidized carbon (assigned to carbohydrates) on fiber surface. The same conclusions were found with FTIR where WPC strength decreases as lignin peaks intensity increases. Esterification reaction of fibers with MAPE occurs on polar sites of carbohydrates, such as hydroxyls (Osbnd H). Thus, fibers with carbohydrates-rich surface, such as cellulose pulp, produced stronger WPC samples. Other factors such as mechanical interlocking and fiber morphology interfered with the effects of fiber surface chemistry.

  16. A Haptic Guided Robotic System for Endoscope Positioning and Holding.

    Science.gov (United States)

    Cabuk, Burak; Ceylan, Savas; Anik, Ihsan; Tugasaygi, Mehtap; Kizir, Selcuk

    2015-01-01

    To determine the feasibility, advantages, and disadvantages of using a robot for holding and maneuvering the endoscope in transnasal transsphenoidal surgery. The system used in this study was a Stewart Platform based robotic system that was developed by Kocaeli University Department of Mechatronics Engineering for positioning and holding of endoscope. After the first use on an artificial head model, the system was used on six fresh postmortem bodies that were provided by the Morgue Specialization Department of the Forensic Medicine Institute (Istanbul, Turkey). The setup required for robotic system was easy, the time for registration procedure and setup of the robot takes 15 minutes. The resistance was felt on haptic arm in case of contact or friction with adjacent tissues. The adaptation process was shorter with the mouse to manipulate the endoscope. The endoscopic transsphenoidal approach was achieved with the robotic system. The endoscope was guided to the sphenoid ostium with the help of the robotic arm. This robotic system can be used in endoscopic transsphenoidal surgery as an endoscope positioner and holder. The robot is able to change the position easily with the help of an assistant and prevents tremor, and provides a better field of vision for work.

  17. Engine Materials Compatibility with Alternate Fuels

    Energy Technology Data Exchange (ETDEWEB)

    Thomson, Jeffery K [ORNL; Pawel, Steven J [ORNL; Wilson, Dane F [ORNL

    2013-05-01

    The compatibility of aluminum and aluminum alloys with synthetic fuel blends comprised of ethanol and reference fuel C (a 50/50 mix of toluene and iso-octane) was examined as a function of water content and temperature. Commercially pure wrought aluminum and several cast aluminum alloys were observed to be similarly susceptible to substantial corrosion in dry (< 50 ppm water) ethanol. Corrosion rates of all the aluminum materials examined were accelerated by increased temperature and ethanol content in the fuel mixture, but inhibited by increased water content. Pretreatments designed to stabilize passive films on aluminum increased the incubation time for onset of corrosion, suggesting film stability is a significant factor in the mechanism of corrosion.

  18. Engine Materials Compatability with Alternative Fuels

    Energy Technology Data Exchange (ETDEWEB)

    Pawel, Steve [Oak Ridge National Laboratory; Moore, D. [USCAR

    2013-04-05

    The compatibility of aluminum and aluminum alloys with synthetic fuel blends comprised of ethanol and reference fuel C (a 50/50 mix of toluene and iso-octane) was examined as a function of water content and temperature. Commercially pure wrought aluminum and several cast aluminum alloys were observed to be similarly susceptible to substantial corrosion in dry (< 50 ppm water) ethanol. Corrosion rates of all the aluminum materials examined were accelerated by increased temperature and ethanol content in the fuel mixture, but inhibited by increased water content. Pretreatments designed to stabilize passive films on aluminum increased the incubation time for onset of corrosion, suggesting film stability is a significant factor in the mechanism of corrosion.

  19. Toward Clinically Compatible Phase-Contrast Mammography.

    Directory of Open Access Journals (Sweden)

    Kai Scherer

    Full Text Available Phase-contrast mammography using laboratory X-ray sources is a promising approach to overcome the relatively low sensitivity and specificity of clinical, absorption-based screening. Current research is mostly centered on identifying potential diagnostic benefits arising from phase-contrast and dark-field mammography and benchmarking the latter with conventional state-of-the-art imaging methods. So far, little effort has been made to adjust this novel imaging technique to clinical needs. In this article, we address the key points for a successful implementation to a clinical routine in the near future and present the very first dose-compatible and rapid scan-time phase-contrast mammograms of both a freshly dissected, cancer-bearing mastectomy specimen and a mammographic accreditation phantom.

  20. Fuel System Compatibility Issues for Prometheus-1

    Energy Technology Data Exchange (ETDEWEB)

    DC Noe; KB Gibbard; MH Krohn

    2006-01-20

    Compatibility issues for the Prometheus-1 fuel system have been reviewed based upon the selection of UO{sub 2} as the reference fuel material. In particular, the potential for limiting effects due to fuel- or fission product-component (cladding, liner, spring, etc) chemical interactions and clad-liner interactions have been evaluated. For UO{sub 2}-based fuels, fuel-component interactions are not expected to significantly limit performance. However, based upon the selection of component materials, there is a potential for degradation due to fission products. In particular, a chemical liner may be necessary for niobium, tantalum, zirconium, or silicon carbide-based systems. Multiple choices exist for the configuration of a chemical liner within the cladding; there is no clear solution that eliminates all concerns over the mechanical performance of a clad/liner system. A series of tests to evaluate the performance of candidate materials in contact with real and simulated fission products is outlined.

  1. fMRI-Compatible Electromagnetic Haptic Interface.

    Science.gov (United States)

    Riener, R; Villgrattner, T; Kleiser, R; Nef, T; Kollias, S

    2005-01-01

    A new haptic interface device is suggested, which can be used for functional magnetic resonance imaging (fMRI) studies. The basic component of this 1 DOF haptic device are two coils that produce a Lorentz force induced by the large static magnetic field of the MR scanner. A MR-compatible optical angular encoder and a optical force sensor enable the implementation of different control architectures for haptic interactions. The challenge was to provide a large torque, and not to affect image quality by the currents applied in the device. The haptic device was tested in a 3T MR scanner. With a current of up to 1A and a distance of 1m to the focal point of the MR-scanner it was possible to generate torques of up to 4 Nm. Within these boundaries image quality was not affected.

  2. Developing 2 C-compatible investment criteria

    Energy Technology Data Exchange (ETDEWEB)

    Roeser, Frauke [NewClimate - Institute for Climate Policy and Global Sustainability gGmbH, Bonn (Germany); Weischer, Lutz [Germanwatch e.V., Koeln (Germany); Thomae, Jakob [2degrees Investing Initiative, New York, NY (United States); Hoehne, Niklas; Hagemann, Markus; El Alaoui, Alexander; Bals, Christoph; Eckstein, David; Kreft, Soenke; Rosse, Morten

    2015-11-30

    This report studies the development of criteria for assessing the compatibility of financial investments with the international goal to limit global temperature increase to below 2 C above pre-industrial levels. The findings are intended as a starting point and a key input for a longer term process to develop consensus-based 2 C investing criteria. The focus here is placed on investments in projects and physical assets, in particular of development and climate finance organisations. In order to limit global temperature increase to 2 C, global greenhouse gas (GHG) emissions will have to be reduced significantly, eventually to zero, during the course of this century. This requires shifting capital from high to low carbon investments as well as significant capital mobilisation for investments in 2 C-compatible infrastructure. Given the long lifetime of physical assets, and the urgency of decarbonisation over the coming decades, this needs to begin today. Public financial institutions can play a prominent role in contributing to aligning investment flows with the 2 C limit, as well as in closing the current infrastructure investment gap, responding to their explicit or implicit climate mandates and leadership role in the finance sector. The majority of international financial institutions integrate climate considerations into their finance decisions to some degree, and are familiar with different types of criteria, including positive and negative lists, qualitative and quantitative benchmarks, and the use of shadow carbon pricing. However, current approaches do not link to the 2 C limit. 2 C investment criteria are therefore needed to guide investors in this regard. Such criteria may also support other purposes, including an understanding of climate risks and improved reporting and accountability.

  3. CMOS-compatible spintronic devices: a review

    Science.gov (United States)

    Makarov, Alexander; Windbacher, Thomas; Sverdlov, Viktor; Selberherr, Siegfried

    2016-11-01

    For many decades CMOS devices have been successfully scaled down to achieve higher speed and increased performance of integrated circuits at lower cost. Today’s charge-based CMOS electronics encounters two major challenges: power dissipation and variability. Spintronics is a rapidly evolving research and development field, which offers a potential solution to these issues by introducing novel ‘more than Moore’ devices. Spin-based magnetoresistive random-access memory (MRAM) is already recognized as one of the most promising candidates for future universal memory. Magnetic tunnel junctions, the main elements of MRAM cells, can also be used to build logic-in-memory circuits with non-volatile storage elements on top of CMOS logic circuits, as well as versatile compact on-chip oscillators with low power consumption. We give an overview of CMOS-compatible spintronics applications. First, we present a brief introduction to the physical background considering such effects as magnetoresistance, spin-transfer torque (STT), spin Hall effect, and magnetoelectric effects. We continue with a comprehensive review of the state-of-the-art spintronic devices for memory applications (STT-MRAM, domain wall-motion MRAM, and spin-orbit torque MRAM), oscillators (spin torque oscillators and spin Hall nano-oscillators), logic (logic-in-memory, all-spin logic, and buffered magnetic logic gate grid), sensors, and random number generators. Devices with different types of resistivity switching are analyzed and compared, with their advantages highlighted and challenges revealed. CMOS-compatible spintronic devices are demonstrated beginning with predictive simulations, proceeding to their experimental confirmation and realization, and finalized by the current status of application in modern integrated systems and circuits. We conclude the review with an outlook, where we share our vision on the future applications of the prospective devices in the area.

  4. Computer-Aided Endoscopic Diagnosis Without Human-Specific Labeling.

    Science.gov (United States)

    Wang, Shuai; Cong, Yang; Fan, Huijie; Liu, Lianqing; Li, Xiaoqiu; Yang, Yunsheng; Tang, Yandong; Zhao, Huaici; Yu, Haibin

    2016-11-01

    Most state-of-the-art computer-aided endoscopic diagnosis methods require pixelwise labeled data to train various supervised machine learning models. However, it is a tedious and time-consuming work to collect sufficient precisely labeled image data. Fortunately, we can easily obtain huge endoscopic medical reports including the diagnostic text and images, which can be considered as weakly labeled data. In this paper, our motivation is to design a new computer-aided endoscopic diagnosis system without human specific labeling; in comparison with most state of the arts, ours only depends on the endoscopic images with weak labels mined from the diagnostic text. To achieve this, we first cast the endoscopic image folder and included images as bag and instances and represent each instance based on the global bag-of-words model. We then adopt a feature mapping scheme to represent each bag by mining the most suspicious lesion instance from each positive bag automatically. In order to achieve self-online updating from sequential new coming data, an online metric learning method is used to optimize the bag-level classification. Our computer-aided endoscopic diagnosis system achieves an AUC of 0.93 on a new endoscopic image dataset captured from 424 volunteers with more than 12k images. The system performance outperforms other state of the arts when we mine the most positive instances from positive bags and adopt the online phase to mine more information from the unseen bags. We present the first weakly labeled endoscopic image dataset for computer-aided endoscopic diagnosis and a novel system that is suitable for use in clinical settings.

  5. [Combined transgastric and transcolonic endoscopic salpingectomy: experiment with pigs].

    Science.gov (United States)

    Li, Wen; Sun, Gang; Wang, Xiang-Dong; Xiao, Jian-Guo; Sun, Guo-Hui; Huang, Xue-Fei; Kantsevoy, Sergey V

    2008-04-08

    To compare the feasibility and safety of combined transgastric and transcolonic dual approach and those of transgastric single approach in endoscopic salpingectomy. Two female Chinese Nongda miniature pigs underwent gastric and colonic lavage with tap water followed by disinfection of mucosa with 1:10 iodophor. An endoscope was inserted and the colonic wall was punctured with a needle knife, dilated with a balloon-dilator and a double-channel endoscope was advanced into the peritoneal cavity. Under direct observation through this endoscope, a trans-gastric entrance was made with the second double-channel endoscope. With the help of transcolonic endoscope, the left Fallopian tube was ligated and partially resected using the transgastric endoscope. With the help of transgastric endoscope, liver biopsy was performed using the transcolonic endoscope. Finally, the gastric incision was closed with 3 clips and the colonic incision was closed with a loop and a clip. Antibiotics were used for 3 days following the procedures. Seventeen days later laparotomy was performed to observe the infection, visceral damage and adhesion, healing of the incisions of gastrointestinal duct, etc. Compared with the single route, the dual routes were more convenient to perform the liver biopsy and salpingectomy. The pigs drank and ate normally soon after the resuscitation. The pigs looked well and gained weight during 2 weeks after the operation. Repeat endoscopy in 2 weeks showed a well-healed gastric incision with 2 clips still in place and a healed colonic incision with 1 clip still attached. The necropsy revealed a complete transmural healing of the gastric incision with minimal adhesion and a complete healing of the colonic incision without any adhesion. Few adhesions were found around the liver biopsy site and the salpingectomy site without any intraperitoneal infection or organ damage. Combined transgastric and transcolonic approach appears safe and feasible and facilitates

  6. Industrial Applications of Graphite Fluoride Fibers

    Science.gov (United States)

    Hung, Ching-Cheh; Kucera, Donald

    1991-01-01

    Based on fluorination technology developed during 1934 to 1959, and the fiber technology developed during the 1970s, a new process was developed to produce graphite fluoride fibers. In the process, pitch based graphitized carbon fibers are at first intercalated and deintercalated several times by bromine and iodine, followed by several cycles of nitrogen heating and fluorination at 350 to 370 C. Electrical, mechanical, and thermal properties of this fiber depend on the fluorination process and the fluorine content of the graphite fluoride product. However, these properties are between those of graphite and those of PTFE (Teflon). Therefore, it is considered to be a semiplastic. The physical properties suggest that this new material may have many new and unexplored applications. For example, it can be a thermally conductive electrical insulator. Its coefficient of thermal expansion (CTE) can be adjusted to match that of silicon, and therefore, it can be a heat sinking printed circuit board which is CTE compatible with silicon. Using these fibers in printed circuit boards may provide improved electrical performance and reliability of the electronics on the board over existing designs. Also, since it releases fluorine at 300 C or higher, it can be used as a material to store fluorine and to conduct fluorination. This application may simplify the fluorination process and reduce the risk of handling fluorine.

  7. Endoscopic hemostasis with endoscopic mucosal resection and multiple synchronous early gastric cancers: a case report

    OpenAIRE

    Fujihara Shintaro; Mori Hirohito; Nishiyama Noriko; Kobayashi Mitsuyoshi; Kobara Hideki; Masaki Tsutomu

    2012-01-01

    Abstract Introduction Endoscopic hemostasis for severe upper gastrointestinal bleeding due to tumors, such as gastrointestinal stromal tumors and malignant lymphoma, is temporarily effective. However, permanent hemostasis is difficult in many cases because of diffuse bleeding. Case presentation A 60-year-old Japanese woman was admitted to our hospital with hematemesis. Endoscopy revealed multiple gastric polyps and fresh blood in her stomach. One of the gastric polyps, which was associated wi...

  8. Peroral endoscopic myotomy (POEM) is safe and effective in the setting of prior endoscopic intervention.

    Science.gov (United States)

    Sharata, Ahmed; Kurian, Ashwin A; Dunst, Christy M; Bhayani, Neil H; Reavis, Kevin M; Swanström, Lee L

    2013-07-01

    We aimed to determine the safety and feasibility of peroral endoscopic myotomy (POEM) in the setting of prior endoscopic interventions. This study involves 40 consecutive patients undergoing POEM. POEM was performed for esophageal motility disorders, including achalasia, nutcracker with nonrelaxing lower esophageal sphincter (LES), hypertensive lower esophageal sphincter, and diffuse esophageal spasm. Outcome measures include length of procedure (LOP), intraoperative complications, and dysphagia relief. Forty patients, with a mean age of 54 ± 19 years, underwent POEM. The pre-POEM intervention group consisted of 12 patients (nine achalasia, two nutcracker with nonrelaxing LES, and one diffuse esophageal spasm) who also had previous endoscopic treatment, while the pre-POEM non-intervention group consisted of 28 patients (22 achalasia, 3 hypertensive LES, 2 nutcracker with nonrelaxing LES, and 1 diffuse esophageal spasm). Ten patients had botox injections and two patients had large caliber balloon dilations prior to POEM. The median preoperative Eckardt score was 5 in the pre-POEM intervention group vs 6 in the pre-POEM non-intervention group (p value = 0.4). There was no statistical difference in the mean LOP (134 ± 43 vs 131 ± 41, p = 0.8) or the incidence of intraoperative complications (17 vs 3 %, p = 0.2) between the two groups. There was also no difference in the 6-month postoperative median Eckardt scores between the two groups (1 vs 1, p = 0.4). POEM is safe and effective even following preoperative endoscopic large caliber balloon dilations or botox injection. These interventions do not seem to contribute to increased adverse intraoperative or postoperative clinical outcomes.

  9. Endoscopic management of bleeding gastric varices--an updated overview.

    Science.gov (United States)

    Crisan, Dana; Tantau, Marcel; Tantau, Alina

    2014-10-01

    Gastric varices (GVs) are known to bleed massively and often difficult to manage with conventional techniques. This article aims to overview the endoscopic methods for the management of acute gastric variceal bleeding, especially the advantages and limits of GV obliteration with tissue adhesives, by comparison with band ligation and other direct endoscopic techniques of approach. The results of indirect radiological and surgical techniques of GV treatment are shortly discussed. A special attention is payed to the emerging role of endoscopic ultrasound in the therapy of bleeding GV, in the confirmation of its eradication and in follow-up strategies.

  10. A Lethal Complication of Endoscopic Therapy: Duodenal Intramural Hematoma

    Directory of Open Access Journals (Sweden)

    Turan Calhan

    2015-01-01

    Full Text Available Duodenal intramural hematoma (DIH usually occurs in childhood and young adults following blunt abdominal trauma. It may also develop in the presence of coagulation disorders and may rarely be an iatrogenic outcome of endoscopic procedures. Management of DIH is usually a conservative approach. A case of intramural duodenal hematoma that developed following endoscopic epinephrine sclerotherapy and/or argon plasma coagulation and that was nonresponsive to conservative therapy in a patient with chronic renal failure who died from sepsis is being discussed in this report. Clinicians should be aware of such possible complications after endoscopic hemostasis in patients with coagulation disorders.

  11. Transoral endoscopic thyroidectomy using vestibular approach: updates and evidences.

    Science.gov (United States)

    Anuwong, Angkoon; Kim, Hoon Yub; Dionigi, Gianlorenzo

    2017-06-01

    Recently, natural orifice transluminal endoscopic surgery (NOTES) has been applied in thyroid surgery with transoral access. The benefit of transoral endoscopic thyroidectomy is the potential for scar-free surgery. However, there are many concerns over some aspects, such as infection, recurrent laryngeal nerve injury, and oncological outcome. In this paper, we have reviewed the development history and the current clinical evidence of this innovative surgery. We conclude that the transoral endoscopic thyroidectomy vestibular approach (TOETVA) is feasible and can be considered no longer an experimental operation.

  12. Photonic crystal fibers

    DEFF Research Database (Denmark)

    Lægsgaard, Jesper; Hansen, K P; Nielsen, M D

    2003-01-01

    Photonic crystal fibers having a complex microstructure in the transverse plane constitute a new and promising class of optical fibers. Such fibers can either guide light through total internal reflection or the photonic bandgap effect, In this paper, we review the different types and applications...... of photonic crystal fibers with particular emphasis on recent advances in the field....

  13. Fluorescence Endoscopy in vivo based on Fiber-bundle Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Zufiria, B.; Gomez-Garcia, P.; Stamatakis, K.; Vaquero, J.J.; Fresno, M.; Desco, M.; Ripoll, J.; Arranz, A.

    2016-07-01

    High-resolution imaging techniques have become important for the determination of the cellular organization that is coupled to organ function. In many cases the organ can be viewed without the need of ionizing radiation techniques in an easier way. This is the case of the gastrointestinal tract, an organ that can be directly accessed with endoscopy avoiding any invasive procedure. Here we describe the design, assembly and testing of a fluorescence high-resolution endoscope intended for the study of the cellular organization of the colon in an experimental mouse model of colon carcinoma. Access to the colon of the mouse took place using a fiber-optic bundle that redirects the light coming from a LED to produce fluorescence and detect it back through the fiber bundle. Results from in vivo and ex-vivo test using our fluorescence fiber bundle endoscope show altered tissue structure and destruction of the intestinal crypts in tumor-bearing areas compared with healthy tissue. (Author)

  14. Fiber optic temperature sensor

    Science.gov (United States)

    Sawatari, Takeo (Inventor); Gaubis, Philip A. (Inventor)

    2000-01-01

    A fiber optic temperature sensor uses a light source which transmits light through an optical fiber to a sensor head at the opposite end of the optical fiber from the light source. The sensor head has a housing coupled to the end of the optical fiber. A metallic reflective surface is coupled to the housing adjacent the end of the optical fiber to form a gap having a predetermined length between the reflective surface and the optical fiber. A detection system is also coupled to the optical fiber which determines the temperature at the sensor head from an interference pattern of light which is reflected from the reflective surface.

  15. A randomized trial comparing multiband mucosectomy and cap-assisted endoscopic resection for endoscopic piecemeal resection of early squamous neoplasia of the esophagus

    NARCIS (Netherlands)

    Zhang, Yue-Ming; Boerwinkel, David F.; Qin, Xiumin; He, Shun; Xue, Liyan; Weusten, Bas L. A. M.; Dawsey, Sanford M.; Fleischer, David E.; Dou, Li-Zhou; Liu, Yong; Lu, Ning; Bergman, Jacques J. G. H. M.; Wang, Gui-Qi

    2016-01-01

    Piecemeal endoscopic resection for esophageal high grade intraepithelial neoplasia (HGIN) or early squamous cell carcinoma (ESCC) is usually performed by cap-assisted endoscopic resection. This requires submucosal lifting and multiple snares. Multiband mucosectomy (MBM) uses a modified variceal band

  16. Single incision endoscopic surgery for lumbar hernia.

    Science.gov (United States)

    Kawaguchi, Masahiko; Ishikawa, Norihiko; Shimizu, Satsuki; Shin, Hisato; Matsunoki, Aika; Watanabe, Go

    2011-01-01

    Single Incision Endoscopic Surgery (SIES) has emerged as a less invasive surgery among laparoscopic surgeries, and this approach for incisional hernia was reported recently. This is the first report of SIES for an incisional lumbar hernia. A 66-year-old Japanese woman was referred to our institution because of a left flank hernia that developed after left iliac crest bone harvesting. A 20-mm incision was created on the left side of the umbilicus and all three trocars (12, 5, and 5 mm) were inserted into the incision. The hernial defect was 14 × 9 cm and was repaired with intraperitoneal onlay mesh and a prosthetic graft. The postoperative course was uneventful. SIES for lumbar hernia offers a safe and effective outcome equivalent compared to laparoscopic surgery. In addition, SIES is less invasive and has a cosmetic benefit.

  17. Acute Vision Loss Following Endoscopic Sinus Surgery

    Directory of Open Access Journals (Sweden)

    Serena Byrd

    2017-01-01

    Full Text Available A 41-year-old female with a history of uterine cancer and Celiac and Raynaud’s Disease presented to our institution with frequent migraines and nasal congestion. She underwent functional endoscopic sinus surgery (FESS and experienced acute unilateral vision loss postoperatively. Rapid recognition of the etiology and effective treatment are paramount given the permanent and irreversible vision loss that can result. Arterial vasospasm following FESS is rare. Patients with autoimmune diseases have perhaps an increased risk for vasospasm secondary to an increased vasoreactive profile. We present the first documented case of nitroglycerin sublingual therapy to successfully treat ophthalmic artery vasospasm following FESS. Nitroglycerin sublingual therapy is a promising treatment for ophthalmic vasospasm secondary to its ability to cross the blood-ocular barrier, its rapid onset of action, and its ability to promote relaxation of vascular smooth muscle.

  18. Endoscopic placement of enteral feeding tubes.

    Science.gov (United States)

    Rafferty, Gerard P; Tham, Tony Ck

    2010-05-16

    Malnutrition is common in patients with acute and chronic illness. Nutritional management of these malnourished patients is an essential part of healthcare. Enteral feeding is one component of nutritional support. It is the preferred method of nutritional support in patients that are not receiving adequate oral nutrition and have a functioning gastrointestinal tract (GIT). This method of nutritional support has undergone progression over recent times. The method of placement of enteral feeding tubes has evolved due to development of new feeding tubes and endoscopic technology. Enteral feeding can be divided into methods that provide short-term and long-term access to the GIT. This review article focuses on the current range of methods of gaining access to the GIT to provide enteral feed.

  19. Prospective analysis of endoscopic vein harvesting.

    Science.gov (United States)

    Patel, A N; Hebeler, R F; Hamman, B L; Hunnicutt, C; Williams, M; Liu, L; Wood, R E

    2001-12-01

    Utilization of bridging vein harvesting (BVH) of saphenous vein grafts (SVG) for coronary artery bypass grafting (CABG) results in large wounds with great potential for pain and infection. Endoscopic vein harvesting (EVH) may significantly reduce the morbidity associated with SVG harvesting. A prospective database of 200 matched patients receiving EVH and BVH was compared. The patients all underwent CABG done over a period of 4 months (April to August 2000). Patients were excluded if they had prior vein harvesting. The EVH and BVH group included 100 patients each with similar demographics. The patients in the EVH group had significantly fewer wound complications, mean days to ambulation, and total length of stay (P BVH in patients undergoing CABG.

  20. Automatic specular reflections removal for endoscopic images

    Science.gov (United States)

    Tan, Ke; Wang, Bin; Gao, Yuan

    2017-07-01

    Endoscopy imaging is utilized to provide a realistic view about the surfaces of organs inside the human body. Owing to the damp internal environment, these surfaces usually have a glossy appearance showing specular reflections. For many computer vision algorithms, the highlights created by specular reflections may become a significant source of error. In this paper, we present a novel method for restoration of the specular reflection regions from a single image. Specular restoration process starts with generating a substitute specular-free image with RPCA method. Then the specular removed image was obtained by taking the binary weighting template of highlight regions as the weighting for merging the original specular image and the substitute image. The modified template was furthermore discussed for the concealment of artificial effects in the edge of specular regions. Experimental results on the removal of the endoscopic image with specular reflections demonstrate the efficiency of the proposed method comparing to the existing methods.

  1. Endoscopic Optical Enhancement Technologies in IBD

    Directory of Open Access Journals (Sweden)

    Gian Eugenio Tontini

    2013-11-01

    Full Text Available Optical enhancement technologies are emerging as promising tools to improve diagnosis and clinical management of patients with inflammatory bowel diseases (IBD. The use of dye-based and dye-less chromoendoscopy may improve either characterisation of mucosal inflammation or detection of dysplastic and early neoplastic lesions. Confocal laser endomicroscopy and endocytoscopy both allow for in vivo and real-time microscopic analysis of the tissue. Moreover, the newly introduced molecular imaging has now also become feasible for in vivo diagnosis in IBD. This review focuses on the more recent progresses of advanced endoscopic imaging techniques in the setting of IBD and provides the reader with an updated overview on accepted clinical evidence and ongoing fields of research.

  2. MR-guided endoscopic sinus surgery.

    Science.gov (United States)

    Hsu, L; Fried, M P; Jolesz, F A

    1998-08-01

    We describe an interactive, intraoperative imaging-guided method for performing endoscopic sinus surgery (ESS) within a vertically open MR system. The procedure was performed with intraoperative imaging using a 0.5-T magnet with a 56-cm vertical gap. Interactive control of imaging planes was accomplished by optical tracking with two infrared light-emitting diodes mounted on an aspirator probe. The probe's position defined the location of the orthogonal imaging planes. Twelve patients with varying degrees of sinus disease underwent ESS with MR imaging guidance. Patients had acute and chronic sinusitis, nasal polyposis causing airway obstruction, or tumor requiring tissue biopsy. All procedures were performed with the patients under general anesthesia. The integration of endoscopy with optical tracking and intraoperative interactive imaging allowed localization of anatomic landmarks during ESS. No complications were encountered.

  3. Quality of endoscopic surveillance of Barrett's esophagus

    DEFF Research Database (Denmark)

    Vogt, Jes Sefland; Larsen, Anders Christian; Sommer, Thorbjørn

    2018-01-01

    OBJECTIVES: The aim of this study was to evaluate adherence to Barrett's esophagus (BE) surveillance guidelines in Denmark. METHODS: The Danish Pathology Registry was used to identify 3692 patients. A total of 300 patients were included by drawing a simple random sample. Description of the BE seg......OBJECTIVES: The aim of this study was to evaluate adherence to Barrett's esophagus (BE) surveillance guidelines in Denmark. METHODS: The Danish Pathology Registry was used to identify 3692 patients. A total of 300 patients were included by drawing a simple random sample. Description...... with insufficient quality of BE surveillance. Lack of endoscopic evidence of BE in the Danish Pathology Registry may have underestimated the incidence of adenocarcinoma in BE patients in previous studies....

  4. [Natural orifice transluminal endoscopic surgery: current situation].

    Science.gov (United States)

    Delgado, Salvadora; Ibarzábal, Ainitze; Fernández-Esparrach, Glòria

    2008-10-01

    Natural orifice transluminal endoscopic surgery (NOTES) is the paradigm of the evolution of minimally invasive surgery. The laparoscopic revolution> has introduced new ideas in general surgery, one of them being that modern surgery is the work of multidisciplinary teams. A clear example of this is provided by NOTES. The aim of this type of surgery is to perform conventional laparoscopic procedures without incision, using flexible endoscopic technology usually employed in the diagnosis and treatment of intraluminal lesions and reaching the inside of the abdominal cavity through natural orifices (mouth, anus, vagina and even urethra). This type of access opens a highly interesting field for certain types of patients, such as those with high surgical risk, the morbidly obese, and those with multiple prior abdominal interventions or surgical wound infections. Animal models have shown that a wide variety of interventions (cholecystectomy, appendicectomy, splenectomy, hysterectomy, tubal ligations, gastroenteroanastomosis, peritoneoscopy, liver biopsy and herniorrhaphy, among others) can be performed. However, before use in humans, this new technique must be shown to be safe and to provide real advantages for patients. To do this, a series of issues, including safe methods for closure of the gastric incision and the avoidance of infections, among others, must be solved. Another critical element for the development of this new type of surgery is the creation of appropriate instrumentation, requiring input not only from medical professionals but also from engineers and industry. The present article describes the major advances made in NOTES since this technique was first described and analyzes the risks and potential benefits associated with this novel procedure.

  5. Endoscopic Management of Idiopathic Subglottic Stenosis.

    Science.gov (United States)

    Shabani, Sepehr; Hoffman, Matthew R; Brand, William T; Dailey, Seth H

    2017-02-01

    To describe a homogeneous idiopathic subglottic stenosis (ISS) population undergoing endoscopic balloon dilation and evaluate factors affecting inter-dilation interval (IDI). Retrospective review of 37 patients. Co-morbidity prevalence versus normal population was evaluated using chi-square tests. Correlations were evaluated using Pearson product moment tests. Independent samples t tests/rank sum tests assessed differences between groups of interest. All patients were female aged 45.9 ± 15.4 years at diagnosis. Four required a tracheotomy during management. Most prevalent co-morbidity was gastroesophageal reflux disease (GERD) (64.9%; P = .036). Body mass indices (BMI) at first and most recent dilation were 29.8 and 30.8 ( P = .564). Degree of stenosis before first dilation was 53 ± 14%. Patients underwent 3.8 ± 1.8 dilations (range, 1-11). Average IDI was 635 ± 615 days (range, 49-3130 days), including 556 ± 397 days for patients receiving concomitant steroid injection and 283 ± 36 for those who did not ( P = .079). Inter-dilation interval was not correlated with BMI ( r = 0.0486; P = .802) or number of co-morbidities ( r = -0.225, P = .223). Most patients with ISS can be managed endoscopically, and IDI may be increased with steroid injection. Gastroesophageal reflux disease is a common co-morbidity. Body mass index did not change over time despite potential effects on exercise tolerance; BMI did not affect IDI. Methods to determine optimal timing for next intervention are warranted.

  6. Endoscopic ultrasound practice survey in latin america.

    Science.gov (United States)

    Drigo, Juliana Marques; Castillo, Cecilia; Wever, Wallia; Obaldía, José Ricardo Ruíz; Fillipi, Sheila; Ribeiro, Manoel C S A; Rossini, Lucio G B

    2013-10-01

    Endoscopic ultrasound (EUS) has become an important imaging modality for the diagnosis, staging and treatment of gastrointestinal disorders. However, no official data exists regarding clinical EUS practice in Latin America (LA). This study assessed current EUS practice and training. A direct mail survey questionnaire was sent to 268 Capítulo Latino Americano de Ultrasonido Endoscópico members between August 2012 and January 2013. The questionnaire was sent out in English, Spanish and Portuguese languages and was available through the following site: http://www.cleus-encuesta.com. Responses were requested only from physicians who perform EUS. A total of 70 LA physicians answered the questionnaire until January 2013. Most of the participants were under 42 years of age (53%) and 80% were men. Most participants (45.7%) perform EUS in Brazil, 53% work in a private hospital. The majority (70%) also perform endoscopic retrograde cholangiopancreatography. A total 42% had performed EUS for 2 years or less and 22.7% for 11 years or more. Only 10% performed more than 5000 EUS. The most common indication was an evaluation of pancreatic-biliary-ampullary lesions. Regarding training, 48.6% had more than 6 months of dedicated hands-on EUS and 37% think that at least 6 months of formal training is necessary to acquire competence. Furthermore, 64% think that more than 50 procedures for pancreatic-biliary lesions are necessary. This survey provides insight into the status of EUS in LA. EUS is performed mostly by young endoscopists in LA. Diagnostic upper EUS is the most common EUS procedure. Most endosonographers believe that formal training is necessary to acquire competence.

  7. Endoscopic inter laminar management of lumbar disease

    Science.gov (United States)

    Yadav, Yad Ram; Parihar, Vijay; Kher, Yatin; Bhatele, Pushp Raj

    2016-01-01

    Discectomy for lumbar disc provides faster relief in acute attack than does conservative management. Long-term results of open, microscopy-, and endoscopy-assisted discectomy are same. Early results of endoscopy-assisted surgery are better as compared to that of open surgery in terms of better visualization, smaller incision, reduced hospital stay, better education, lower cost, less pain, early return to work, and rehabilitation. Although microscopic discectomy also has comparable advantages, endoscopic-assisted technique better addresses opposite side pathology. Inter laminar technique (ILT) and trans foraminal technique (TFT) are two main endoscopic approaches for lumbar pathologies. Endoscopy-assisted ILT can be performed in recurrent, migrated, and calcified discs. All lumbar levels including L5-S1 level, intracanalicular, foraminal disc, lumbar canal and lateral recess stenosis, multiple levels, and bilateral lesions can be managed by ILT. Migrated, calcified discs, L5-S1 pathology, lumbar canal, and lateral recess stenosis can be better approached by ILT than by TFT. Most spinal surgeons are familiar with anatomy of ILT. It can be safely performed in foramen stenosis and in uncooperative and anxious patients. There is less risk of exiting nerve root damage, especially in short pedicles and in presence of facet osteophytes as compared to TFT. On the other hand, ILT is more invasive than TFT with more chances of perforations of the dura matter, pseudomeningocele formation, and cerebrospinal fluid fistula in early learning curve. Obtaining microsurgical experience, attending workshops, and suitable patient selection can help shorten the learning curve. Once adequate skill is acquired, this procedure is safe and effective. The surgeon must be prepared to convert to an open procedure, especially in early learning curve. Spinal endoscopy is likely to achieve more roles in future. Endoscopy-assisted ILT is a safer alternative to the microscopic technique. PMID

  8. Endoscopic coverage of fetal myelomeningocele in utero.

    Science.gov (United States)

    Bruner, J P; Richards, W O; Tulipan, N B; Arney, T L

    1999-01-01

    Our goal was to evaluate the safety and efficacy of minimally invasive surgery for the coverage of myelomeningocele in utero. Women in the mid-second trimester of a pregnancy complicated by fetal myelomeningocele were offered an experimental procedure designed to prevent ongoing exposure of the spinal cord to the intrauterine environment. The procedure consisted of maternal laparotomy while the patient was under both general and epidural anesthesia, with exposure of the gravid uterus. Endoscopic ports were placed for camera and operating instruments. Amniotic fluid was removed and replaced with carbon dioxide. The fetus was then positioned and a maternal split-thickness skin graft was placed over the exposed spinal cord or neural elements. The skin graft and a covering of Surgicel Absorbable Hemostat were attached with fibrin glue prepared from autologous cryoprecipitate. Four fetuses with open myelomeningocele underwent endoscopic coverage of the spinal lesion between 22 weeks 3 days and 24 weeks 3 days of gestation. One infant, delivered by planned cesarean section at 35 weeks' gestation after demonstration of fetal lung maturity, is almost 3 years old. A second infant was delivered by cesarean section at 28 weeks after preterm labor and is now almost 6 months old. Both survivors manifest only mild motor and somatosensory deficits. One fetus who was delivered 1 week after operation after development of amnionitis died in the delivery room of extreme prematurity. The final fetus died intraoperatively from abruptio placentae. Minimally invasive fetal surgery appears to constitute a feasible approach to nonlethal fetal malformations that result in progressive and disabling organ damage.

  9. Experimental Investigation and Analysis of Mercerized and Citric Acid Surface Treated Bamboo Fiber Reinforced Composite

    Science.gov (United States)

    De, Jyotiraman; Baxi, R. N., Dr.

    2017-08-01

    Mercerization or NaOH fiber surface treatment is one of the most popular surface treatment processes to make the natural fibers such as bamboo fibers compatible for use as reinforcing material in composites. But NaOH being a chemical is hazardous and polluting to the nature. This paper explores the possibility of use of naturally derived citric acid for bamboo fiber surface treatment and its comparison with NaOH treated Bamboo Fiber Composites. Untreated, 2.5 wt% NaOH treated and 5 wt% citric acid treated Bamboo Fiber Composites with 5 wt% fiber content were developed by Hand Lay process. Bamboo mats made of bamboo slivers were used as reinforcing material. Mechanical and physical characterization was done to compare the effects of NaOH and citric acid bamboo fiber surface treatment on mechanical and physical properties of Bamboo Fiber Composite. The experiment data reveals that the tensile and flexural strength was found to be highest for citric acid and NaOH treated Bamboo Fiber Composite respectively. Water absorption tendency was found more than the NaOH treated Bamboo Fiber Composites. SEM micrographs used to analyze the morphology of fracture surface of tensile test specimens confirm improvement in fiber-matrix interface bonding due to surface treatment of bamboo fibers.

  10. Optical microscope and tapered fiber coupling apparatus for a dilution refrigerator.

    Science.gov (United States)

    MacDonald, A J R; Popowich, G G; Hauer, B D; Kim, P H; Fredrick, A; Rojas, X; Doolin, P; Davis, J P

    2015-01-01

    We have developed a system for tapered fiber measurements of optomechanical resonators inside a dilution refrigerator, which is compatible with both on- and off-chip devices. Our apparatus features full three-dimensional control of the taper-resonator coupling conditions enabling critical coupling, with an overall fiber transmission efficiency of up to 70%. Notably, our design incorporates an optical microscope system consisting of a coherent bundle of 37,000 optical fibers for real-time imaging of the experiment at a resolution of ∼1 μm. We present cryogenic optical and optomechanical measurements of resonators coupled to tapered fibers at temperatures as low as 9 mK.

  11. Kagome Hollow-Core Photonic Crystal Fiber Resonator for Rotation Sensing

    CERN Document Server

    Fsaifes, Ihsan; Debord, Benoît; Gérôme, Frédéric; Baz, Assaad; Humbert, Georges; Benabid, Fetah; Schwartz, Sylvain; Bretenaker, Fabien

    2016-01-01

    We investigate the performances of a Kagome Hollow-Core Photonic Crystal Fiber resonator for rotation sensing applications. The use of a large mode field diameter Kagome fiber permits to reduce the free space fiber-to-fiber coupling losses, allowing the realization of cavities with finesses compatible with the angular random walk required for medium to high performance rotation sensing, while minimizing the Kerr effect induced non reciprocities. Experiments show encouraging results that could lead to a compact, low cost, and robust medium for high performance gyroscope.

  12. Polyurethane Organosilicate Nanocomposites as Blood Compatible Coatings

    Directory of Open Access Journals (Sweden)

    Johnson H. Y. Chung

    2012-02-01

    Full Text Available Polymer clay nanocomposites (NCs show remarkable potential in the field of drug delivery due to their enhanced barrier properties. It is hypothesised that well dispersed clay particles within the polymer matrix create a tortuous pathway for diffusing therapeutic molecules, thereby resulting in more sustained release of the drug. As coatings for medical devices, these materials can simultaneously modulate drug release and improve the mechanical performance of an existing polymer system without introducing additional materials with new chemistries that can lead to regulatory concerns. In this study, polyurethane organosilicate nanocomposites (PUNCs coated onto stainless steel wires were evaluated for their feasibility as blood compatible coatings and as drug delivery systems. Heparin was selected as the model drug to examine the impact of silicate loading and modifier chain length in modulating release. Findings revealed that better dispersion was achieved from samples with lower clay loadings and longer alkyl chains. The blood compatibility of PUNCs as assessed by thrombin generation assays showed that the addition of silicate particles did not significantly decrease the thrombin generation lag time (TGT, p = 0.659 or the peak thrombin (p = 0.999 of polyurethane (PU. PUNC coatings fabricated in this research were not cytotoxic as examined by the cell growth inhibition assay and were uniformly intact, but had slightly higher growth inhibition compared to PU possibly due to the presence of organic modifiers (OM. The addition of heparin into PUNCs prolonged the TGT, indicating that heparin was still active after the coating process. Cumulative heparin release profiles showed that the majority of heparin released was from loosely attached residues on the surface of coils. The addition of heparin further prolonged the TGT as compared to coatings without added heparin, but a slight decrease in heparin activity was observed in the NCs

  13. EVA-Compatible Microbial Swab Tool

    Science.gov (United States)

    Rucker, Michelle A.

    2016-01-01

    When we send humans to search for life on Mars, we'll need to know what we brought with us versus what may already be there. To ensure our crewed spacecraft meet planetary protection requirements—and to protect our science from human contamination—we'll need to know whether micro-organisms are leaking/venting from our ships and spacesuits. This is easily done by swabbing external vents and suit surfaces for analysis, but requires a specialized tool for the job. Engineers at the National Aeronautics and Space Administration (NASA) recently developed an Extravehicular Activity (EVA)-compatible swab tool that can be used to sample current space suits and life support systems. Data collected now will influence Mars life support and EVA hardware early in the planning process, before design changes become difficult and expensive.NASA’s EVA swab tool pairs a Space Shuttle-era tool handle with a commercially available swab tip mounted into a custom-designed end effector. A glove-compatible release mechanism allows the handle to quickly switch between swab tips, much like a shaving razor handle can snap onto a disposable blade cartridge. Swab tips are stowed inside individual sterile containers, each fitted with a microbial filter that allows the container to equalize atmospheric pressure, but prevents cabin contaminants from rushing into the container when passing from the EVA environment into a pressurized cabin. A bank of containers arrayed inside a tool caddy allows up to six individual samples to be collected during a given spacewalk.NASA plans to use the tool in 2016 to collect samples from various spacesuits during ground testing to determine what (if any) human-borne microbial contamination leaks from the suit under simulated thermal vacuum conditions. Next, the tool will be used on board the International Space Station to assess the types of microbial contaminants found on external environmental control and life support system vents. Data will support

  14. Endoscopic sensing of pH in the distal lung (Conference Presentation)

    Science.gov (United States)

    Choudhury, Debaditya; Tanner, Michael G.; McAughtrie, Sarah; Yu, Fei; Mills, Bethany; Choudhary, Tushar R.; Seth, Sohan; Craven, Thomas; Stone, James M.; Mati, Ioulia K.; Campbell, Colin J.; Bradley, Mark; Williams, Christopher K.; Dhaliwal, Kevin; Birks, Timothy A.; Thomson, Robert R.

    2017-04-01

    In healthy humans, the physiological state in the distal lung alveolar acinar units is tightly regulated by normal homeostatic mechanisms. Pulmonary abnormalities such as chronic obstructive pulmonary disease, that are characterized by recurrent cycles of inflammation and infection involving dense infiltration by myeloid derived peripheral blood cells, may result in significant perturbation of the homeostatic baselines of physiology in addition to host tissue damage. Therefore, the ability to quantify and monitor physiology (e.g. pH, glucose level, oxygen tension) within the alveolar acinar units would provide a key biomarker of distal lung innate defence. Although in vitro modeling of fundamental biological processes show remarkable sensitivity to physiological aberrations, little is known about the physiological state of the distal lung due to the inability to concurrently access the alveolar sacs and perform real-time sensing. Here we report on previously unobtainable measurements of alveolar pH using a fiber-optic optrode and surface enhanced Raman spectroscopy (SERS) and show that alveolar pH changes in response to ventilation. The endoscope-deployable optrode consisted of para-mercaptobenzoic acid functionalized 150 nm gold nanoshells located at the distal end, and an asymmetric dual-core optical fiber designed for spatially separated optical pump delivery and SERS signal collection in order to circumvent the unwanted Raman signal originating from the fiber itself. We demonstrate a 100-fold increase in SERS signal-to-fiber background ratio and pH sensing at multiple sites in the respiratory acinar units of a whole ex vivo ovine lung model with a measurement accuracy of ± 0.07 pH units.

  15. MEMS ultrasonic probe rotary scanning imaging system for medical endoscope

    Science.gov (United States)

    Chen, Xiaodong; Wen, Shijie; Yu, Daoyin

    2006-11-01

    Medical ultrasonic endoscope is the combination of electronic endoscope and ultrasonic sensor technology. Ultrasonic endoscope sends the ultrasonic probe into coelom through the biopsy channel of an electronic endoscope and rotates it by a micro motor, acquiring fault histology features of digestive organs. Compared with external ultrasonic detection, the system reduces the distance between the transducer and the organ, diminishing the effects on imaging of fats and body cavity gas. On the basis of ultrasonic imaging system, this paper implements a pulse echo imaging system. We describe the ultrasonic probe, emission circuit, receiving circuit and protective circuit in detail. With the demodulation circuit, we get the amplitude of echo which indicates the objects. And to achieve the rotary scan, we design a synchronous control circuit and a data transfer circuit basing on the USB2.0 interface. Finally we get a grey image with 256 grey levels after coordinate conversion.

  16. Diversion neovaginitis after sigmoid vaginoplasty: endoscopic and clinical characteristics

    NARCIS (Netherlands)

    Sluis, W.B. van der; Bouman, M.B.; Meijerink, W.J.H.J.; Elfering, L.; Mullender, M.G.; Boer, N.K. de; Bodegraven, A.A. van

    2016-01-01

    OBJECTIVE: To assess the endoscopic characteristics of the sigmoid-derived neovagina, which have been scarcely described. DESIGN: Prospective observational study. SETTING: University tertiary medical center. PATIENT(S): Patients that underwent sigmoid vaginoplasty. INTERVENTION(S): Patients were

  17. Endoscopic Thermal Fasciotomy for Chronic Exertional Compartment Syndrome.

    Science.gov (United States)

    Voleti, Pramod B; Lebrun, Drake G; Roth, Cameron A; Kelly, John D

    2015-10-01

    Chronic exertional compartment syndrome is an activity-induced condition that occurs when intracompartmental pressures within an osteofascial envelope increase during exercise, leading to reversible ischemic symptoms such as pain, cramping, numbness, or weakness. Nonoperative treatment options for this condition have shown limited success and are often undesirable for the patient given the requirement for activity modification. Traditional surgical treatment options involving open or subcutaneous fasciotomies have more favorable results, but these techniques are associated with significant morbidity. Endoscopically assisted fasciotomy techniques afford the advantages of being minimally invasive, providing excellent visualization, and allowing accelerated rehabilitation. The purpose of this article is to describe a technique for performing endoscopically assisted fasciotomies for chronic exertional compartment syndrome of the lower leg using an entirely endoscopic thermal ablating device. The endoscopic thermal fasciotomy technique is associated with minimal morbidity, ensures excellent hemostasis, and affords an early return to sports.

  18. Endoscopic Thermal Fasciotomy for Chronic Exertional Compartment Syndrome

    Science.gov (United States)

    Voleti, Pramod B.; Lebrun, Drake G.; Roth, Cameron A.; Kelly, John D.

    2015-01-01

    Chronic exertional compartment syndrome is an activity-induced condition that occurs when intracompartmental pressures within an osteofascial envelope increase during exercise, leading to reversible ischemic symptoms such as pain, cramping, numbness, or weakness. Nonoperative treatment options for this condition have shown limited success and are often undesirable for the patient given the requirement for activity modification. Traditional surgical treatment options involving open or subcutaneous fasciotomies have more favorable results, but these techniques are associated with significant morbidity. Endoscopically assisted fasciotomy techniques afford the advantages of being minimally invasive, providing excellent visualization, and allowing accelerated rehabilitation. The purpose of this article is to describe a technique for performing endoscopically assisted fasciotomies for chronic exertional compartment syndrome of the lower leg using an entirely endoscopic thermal ablating device. The endoscopic thermal fasciotomy technique is associated with minimal morbidity, ensures excellent hemostasis, and affords an early return to sports. PMID:26900549

  19. Pattern of Endoscopic Findings of Upper Gastrointestinal Tract in ...

    African Journals Online (AJOL)

    UGT) including gastro esophageal reflux (GERD), peptic ulcer diseases (PU), and upper gastrointestinal malignancies was not studied recently in Sudan. Objectives: The aim of this study is to know the pattern of endoscopic findings of upper ...

  20. Per-oral endoscopic myotomy (POEM) for esophageal achalasia.

    Science.gov (United States)

    Pescarus, Radu; Shlomovitz, Eran; Swanstrom, Lee L

    2014-01-01

    Per-oral endoscopic myotomy (POEM) is a new minimally invasive endoscopic treatment for achalasia. Since the first modern human cases were published in 2008, around 2,000 cases have been performed worldwide. This technique requires advanced endoscopic skills and a learning curve of at least 20 cases. POEM is highly successful with over 90 % improvement in dysphagia while offering patients the advantage of a low impact endoscopic access. The main long-term complication is gastroesophageal reflux (GER) with an estimated incidence of 35 %, similar to the incidence of GER post-laparoscopic Heller with fundoplication. Although POEM represents a paradigm shift in the treatment of achalasia, more long-term data are clearly needed to further define its role in the treatment algorithm of this rare disease.

  1. Treatment Strategy after Incomplete Endoscopic Resection of Early Gastric Cancer

    Science.gov (United States)

    Kim, Sang Gyun

    2016-01-01

    Endoscopic resection of early gastric cancer is defined as incomplete when tumor cells are found at the resection margin upon histopathological examination. However, a tumor-positive resection margin does not always indicate residual tumor; it can also be caused by tissue contraction during fixation, by the cautery effect during endoscopic resection, or by incorrect histopathological mapping. Cases of highly suspicious residual tumor require additional endoscopic or surgical resection. For inoperable patients, argon plasma coagulation can be used as an alternative endoscopic treatment. Immediately after the incomplete resection or residual tumor has been confirmed by the pathologist, clinicians should also decide upon any additional treatment to be carried out during the follow-up period. PMID:27435699

  2. [Current options for percutaneous endoscopic access to the digestive tract

    NARCIS (Netherlands)

    Romkens, T.E.H.; Jong, D.J. de; Kristinsson, J.O.; Wanten, G.J.A.

    2008-01-01

    Four patients, aged 67, 52, 56 and 64 years, respectively, undergoing percutaneous colostomy or jejunostomy are presented to illustrate current options for percutaneous endoscopic access to the digestive tract. The first patient had Parkinson's disease and required percutaneous jejunostomy for

  3. Percutaneous endoscopic lumbar discectomy: Results of first 100 cases

    National Research Council Canada - National Science Library

    Kanthila Mahesha

    2017-01-01

      Background: Lumbar disc herniation is a major cause of back pain and sciatica. The surgical management of lumbar disc prolapse has evolved from exploratory laminectomy to percutaneous endoscopic discectomy...

  4. IMPLANTATION METASTASIS OF LARYNGEAL CANCER AFTER PERCUTANEOUS ENDOSCOPIC GASTROSTOMY

    Directory of Open Access Journals (Sweden)

    A. O. Guz

    2017-01-01

    Full Text Available Squamous cell head and neck carcinoma is frequently associated with dysphagia. An adequate enteral nutrition is the key to successful treatment and rehabilitation of these patients. Percutaneous endoscopic gastrostomy is the preferred route of feeding and nutritional support in head and neck cancer patients with dysphagia. We report a rare case of implantation metastasis of laryngeal cancer following percutaneous endoscopic gastrostomy. Our experience in treating this complication has been described. Percutaneous endoscopic gastrostomy is a less-invasive procedure than open gastrostomy. Percutaneous endoscopic gastrostomy can be accompanied by severe complications such as implantation metastasis at gastrostomy site. Careful monitoring can provide early detection of this complication and early treatment. 

  5. Endoscopically assisted craniosynostosis surgery (EACS): The craniofacial team Nijmegen experience

    NARCIS (Netherlands)

    Delye, H.H.K.; Arts, S.; Borstlap, W.A.; Blok, L.M.; Driessen, J.J.; Meulstee, J.W.; Maal, T.J.J.; Lindert, E.J. van

    2016-01-01

    INTRODUCTION: An evaluation of our first 111 consecutive cases of non-syndromic endoscopically assisted craniosynostosis surgery (EACS) followed by helmet therapy. METHODS: Retrospective analysis of a prospective registration database was performed. Age, duration of surgery, length of hospital stay,

  6. Mimicking disinfection and drying of biofilms in contaminated endoscopes

    NARCIS (Netherlands)

    Kovaleva, J.; Degener, J. E.; van der Mei, H. C.

    2010-01-01

    The effects of peracetic acid-based (PAA) disinfectant with, and without, additional drying on Candida albicans, Candida parapsilosis, Pseudomonas aeruginosa and Stenotrophomonas maltophilia, isolated from contaminated flexible endoscopes, in single-and dual-species biofilms were studied. Biofilms

  7. [Experience of managing substernal goiter by totally endoscopic procedure].

    Science.gov (United States)

    Fan, Qing; Gong, Ke; Zhu, Bin; Zhang, Neng-wei

    2014-06-18

    To summarize the experience of managing substernal goiter by totally endoscopic procedure and evaluate the curative effect, we analysed eight patients diagnosed as substernal goiter type I and treated with totally endoscopic technique via central routing approach during March 2011 to June 2013 in Beijing Shijitan Hospital retrospectively. The feasibility, safety and curative effect of this surgical technique were estimated. All the cases were successfully operated with the totally endoscopic procedure, and the pathological result showed that 6 were goiter and the other 2 were minimal papillary carcinoma. None of the patients suffered from any complication, and the median follow up time was 6 months (1-28 months). The totally endoscopic technique is a feasible, safe and cosmic one for managing substernal goiter type I.

  8. Synthesis and application of PLA and PLA/GO fibers through thermo-responsive transformation of PLA particles

    OpenAIRE

    Bolakhrif, Sabah

    2016-01-01

    PLA nanofibers were successively produced by thermo-responsive transformation of PLA particles in water. The morphological structure of the nanofibers could be optimized by the heat treatment as well as the incorporation of GO to the fiber surface. PLA/GO fiber demonstrated a more stable morphology and GO provided good compatibility between PLA and starch. Both PLA and PLA/GO fibers incorporated in starch films resulted in increased thermal stability and mechanical properties. However, the mo...

  9. Electrocardiographic Changes in Elderly Patients During Endoscopic Retrograde Cholangiopancreatography

    Directory of Open Access Journals (Sweden)

    NG Kounis

    2003-01-01

    Full Text Available BACKGROUND: Cardiorespiratory complications may occur during gastrointestinal endoscopy, and elderly people seem to be more vulnerable to these complications during endoscopic procedures involving the manipulation of abdominal viscera. OBJECTIVES: To determine the incidence of cardiac arrhythmias, changes in oxygen saturation, heart rate and blood pressure during endoscopic retrograde cholangiopancreatography (ERCP via Holter monitoring in elderly patients older than 70 years of age.

  10. Evaluation of four commercial automatic endoscope washing machines.

    Science.gov (United States)

    Lynch, D A; Porter, C; Murphy, L; Axon, A T

    1992-11-01

    Four commercially available endoscope washing machines (Pyser System 83, Wolf Fiberscope Disinfector, Olympus EW20, Keymed Auto-Disinfector) were evaluated. In most cases the machines were expensive, immobile and noisy, and could only wash one endoscope per cycle. Daily use involved repetitive chores and contact with glutaraldehyde. Disinfection procedures were flawed; no machine auto-disinfected adequately. In conclusion, these machines are unsatisfactory and represent a potential source of serious infection.

  11. Surgical versus endoscopic treatment of bile duct stones

    DEFF Research Database (Denmark)

    Martin, D J; Vernon, D R; Toouli, J

    2006-01-01

    10% to 18% of patients undergoing cholecystectomy for gallstones have common bile duct (CBD) stones. Treatment options for these stones include pre- or post-operative endoscopic retrograde cholangiopancreatography (ERCP) or open or laparoscopic surgery.......10% to 18% of patients undergoing cholecystectomy for gallstones have common bile duct (CBD) stones. Treatment options for these stones include pre- or post-operative endoscopic retrograde cholangiopancreatography (ERCP) or open or laparoscopic surgery....

  12. Postoperative complications following percutaneous endoscopic gastrostomy are common in children

    DEFF Research Database (Denmark)

    Halvard Hansen, Erik Sören; Qvist, N.; Rasmussen, L.

    2017-01-01

    Aim: Inserting a feeding tube using percutaneous endoscopic gastrostomy may be necessary to ensure that children with eating problems receive sufficient enteral nutrition. The aim of this study was to investigate the perioperative and postoperative complications of percutaneous endoscopic...... were grade 3b complications. No gastrostomy-related deaths were observed, and no single preoperative risk factor was identified. Perioperative complications were experienced by 2.6% of the patients. Conclusion: Gastrostomy feeding tube placement was associated with a high rate of postoperative...

  13. ENDOSCOPIC SLEEVE GASTROPLASTY - MINIMALLY INVASIVE THERAPY FOR PRIMARY OBESITY TREATMENT

    OpenAIRE

    GALVÃO-NETO,Manoel dos Passos; GRECCO,Eduardo; de Souza, Thiago Ferreira; Luiz Gustavo de QUADROS; SILVA, Lyz Bezerra; CAMPOS, Josemberg Marins

    2016-01-01

    ABSTRACT Background: Less invasive and complex procedures have been developed to treat obesity. The successful use of Endoscopic Sleeve Gastroplasty using OverStitch(r) (Apollo Endosurgery, Austin, Texas, USA) has been reported in the literature. Aim: Present technical details of the procedure and its surgical/ endoscopic preliminary outcome. Method: The device was used to perform plications along the greater curvature of the stomach, creating a tubulization similar to a sleeve gastrect...

  14. The optimal endoscopic screening interval for detecting early gastric neoplasms.

    Science.gov (United States)

    Park, Chan Hyuk; Kim, Eun Hye; Chung, Hyunsoo; Lee, Hyuk; Park, Jun Chul; Shin, Sung Kwan; Lee, Yong Chan; An, Ji Yeong; Kim, Hyoung-Il; Cheong, Jae-Ho; Hyung, Woo Jin; Noh, Sung Hoon; Kim, Choong Bae; Lee, Sang Kil

    2014-08-01

    The optimal interval between endoscopic examinations for detecting early gastric neoplasms, including gastric adenomas, has not previously been studied. To clarify the optimal interval between endoscopic examinations for the early diagnosis of both gastric cancers and adenomas. Retrospective study. University-affiliated tertiary-care hospital, Seoul, Korea. Patients who were treated for gastric neoplasms between January 2008 and August 2013. Questionnaire survey for interval between the penultimate endoscopy and diagnosis of a gastric neoplasm. A total of 846 patients were divided into 5 groups according to the interval between endoscopic examinations. The proportion of gastric neoplasms treated with endoscopic submucosal dissection and the proportion of advanced gastric cancers according to the interval between endoscopic examinations. In total, 197, 430, and 219 patients were diagnosed with gastric adenoma, early gastric cancer, and advanced gastric cancer, respectively. In multivariate analysis, the proportion of gastric neoplasms treated with endoscopic submucosal dissection was significantly higher in the ≤12 months, 12 to 24 months, and 24 to 36 months endoscopy interval groups than in the no endoscopy within 5 years group (all P gastric cancers was significantly lower in the ≤12 months and 12 to 24 months endoscopy interval groups than in the no endoscopy within 5 years group (all P gastric neoplasms compared with biennial or triennial endoscopy. We recommend biennial endoscopic screening for gastric neoplasms in order to increase the proportion of lesions discovered while they are still endoscopically treatable and to reduce the number of lesions that progress to advanced gastric cancer. Copyright © 2014 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  15. Mortality reduction from gastric cancer by endoscopic and radiographic screening

    OpenAIRE

    Hamashima, Chisato; Shabana, Michiko; Okada, Katsuo; Okamoto, Mikizo; Osaki, Yoneatsu

    2015-01-01

    To evaluate mortality reduction from gastric cancer by endoscopic screening, we undertook a population?based cohort study in which both radiographic and endoscopic screenings for gastric cancer have been carried out. The subjects were selected from the participants of gastric cancer screening in two cities in Japan, Tottori and Yonago, from 2007 to 2008. The subjects were defined as participants aged 40?79 years who had no gastric cancer screening in the previous year. Follow?up of mortality ...

  16. Sedation Monitoring and Management during Percutaneous Endoscopic Lumbar Discectomy

    OpenAIRE

    Menekse Oksar; Tulin Gumus; Orhan Kanbak

    2016-01-01

    Percutaneous endoscopic laser discectomy (PELD) is a painful intervention that requires deep sedation and analgesia. However, sedation should be light at some point because cooperation by the patient during the procedure is required for successful surgical treatment. Light sedation poses a problem for endotracheal intubation, while patients placed in the prone position during percutaneous endoscopic discectomy pose a problem for airway management. Therefore, under these conditions, sedation s...

  17. Percutaneous endoscopic lumbar discectomy: Results of first 100 cases

    OpenAIRE

    Kanthila Mahesha

    2017-01-01

    Background: Lumbar disc herniation is a major cause of back pain and sciatica. The surgical management of lumbar disc prolapse has evolved from exploratory laminectomy to percutaneous endoscopic discectomy. Percutaneous endoscopic discectomy is the least invasive procedure for lumbar disc prolapse. The aim of this study was to analyze the clinical outcome, quality of life, neurologic function, and complications. Materials and Methods: One hundred patients with lumbar disc prolapse who wer...

  18. IMPLANTATION METASTASIS OF LARYNGEAL CANCER AFTER PERCUTANEOUS ENDOSCOPIC GASTROSTOMY

    OpenAIRE

    Guz, A. O.; A. S. Zakharov; A. V. Garev

    2017-01-01

    Squamous cell head and neck carcinoma is frequently associated with dysphagia. An adequate enteral nutrition is the key to successful treatment and rehabilitation of these patients. Percutaneous endoscopic gastrostomy is the preferred route of feeding and nutritional support in head and neck cancer patients with dysphagia. We report a rare case of implantation metastasis of laryngeal cancer following percutaneous endoscopic gastrostomy. Our experience in treating this complication has been de...

  19. Endoscopic and radiological diagnostics of esophagus diseases in dogs

    OpenAIRE

    Krstić Vanja; Krstić Nikola

    2006-01-01

    In order to expand the range of diagnostic methods for determining diseases of the esophagus and to make them more present in everyday practise, it is desirable to work out in more detail the procedure of endoscopic and radiological examinations, determine their limitations and possibilities, describe the topographic-anatomical and morphological status of the esophagus in an endoscopic and radiological picture, as well as to define which diseases of this organ are most represented. The paper ...

  20. Endoscopic digital holography for measuring flows in opaque vessels

    Science.gov (United States)

    Arévalo, Laura; Palero, Virginia; Lobera, Julia; Arroyo, M. Pilar

    2012-10-01

    In this work a new application of digital holography for the study of cardio vascular diseases is proposed. The simultaneous measurement of the blood flow velocity and the vein wall deformation can be obtained by combining digital holography and endoscopy. Endoscopes are used for the illumination and recording of digital holograms inside a vein model. Two different endoscopes have been used in different vein models in order to test the technique performance. Preliminary results of flow velocity and wall deformation are presented.

  1. Endoscopic Diagnosis of Leiomyosarcoma of the Esophagus, a Rare Neoplasm

    OpenAIRE

    Ravini, Mario; Torre, Massimo; Zanasi, Giulio; Vanini, Marco; Camozzi, Mario

    1998-01-01

    We report a case of leiomyosarcoma of the distal third of the esophagus in a 51-year-old woman presenting with a six-month history of severe epigastric pain, disphagia and weight loss. The diagnosis, suspected on endoscopic examination, was preoperatively acheived by biopsy and immunohistological stain. Surgical treatment was undertaken with good results. Differentiation between leiomyosarcoma and more common esophageal neoplasm may be difficult if based on radiographic and endoscopic appeara...

  2. Endoscopic submucosal dissection in Spain: outcomes and development possibilities

    Directory of Open Access Journals (Sweden)

    Juan J. Vila

    2013-10-01

    Full Text Available Endoscopic submucosal dissection (ESD allows endoscopic, curative, en-bloc resection of superficial malignant or premalignant lesions. This procedure was conceived over 10 years ago in Japan, but has not experienced great expansion in Western countries for different reasons. This article reviews ESD indications and outcomes, and reflects on the reasons that prevent ESD from becoming common clinical practice in Western hospitals. Finally, recommendations on ESD training in our setting are made.

  3. Endoscopic resection for gastric schwannoma with long-term outcomes.

    Science.gov (United States)

    Cai, Ming-Yan; Xu, Jia-Xin; Zhou, Ping-Hong; Xu, Mei-Dong; Chen, Shi-Yao; Hou, Jun; Zhong, Yun-Shi; Zhang, Yi-Qun; Ma, Li-Li

    2016-09-01

    Gastric schwannoma is not so recognized by clinicians as its counterparts. The efficacy of endoscopic resection has not been described yet. Our aim was to assess the efficacy and safety of endoscopic resection in the management of gastric schwannoma. Retrospective data were reviewed from January 2008 to December 2013 in our center. Fourteen patients who had endoscopic resection with the final pathology result of gastric schwannoma were included in the study. Of the 14 patients, there were 12 females and two males. The median age was 59 years (range 32-83). Thirteen tumors (92.9 %) were from the muscularis propria and one located in the submucosa. Endoscopic en bloc resection was achieved in 12 patients (12/14, 85.7 %), including seven cases of endoscopic full-thickness resection (EFTR). The mean resected tumor size was 1.73 ± 1.10 cm (range 0.3-4.0 cm). In one case, endoscopic resection was suspended due to the limited experience of EFTR during the early period of the study. In another case, due to the difficult tumor location (gastric angle) and extraluminal growth pattern, the patient was referred to laparoscopic surgery. In the 12 successful endoscopic resection cases, during the median follow-up time of 4 years (range 17-77 months, one patient lost), no tumor residue, recurrence or metastasis was found. Endoscopic resection is safe and effective in treating gastric schwannoma with excellent long-term outcomes. However, it should be performed with caution because schwannoma is mainly located in the deep muscular layer, which leads to the full-thickness resection of gastric wall.

  4. Bilateral retinal hemorrhage after endoscopic third ventriculostomy: iatrogenic Terson syndrome.

    Science.gov (United States)

    Hoving, Eelco W; Rahmani, Mehrnoush; Los, Leonie I; Renardel de Lavalette, Victor W

    2009-05-01

    A serious ophthalmological complication of an endoscopic third ventriculostomy that created an iatrogenic Terson syndrome is described. A patient with an obstructive hydrocephalus was treated endoscopically, but due to the inadvertent use of a pressure bag during rinsing, in combination with a blocked outflow channel, a steep rise in intracranial pressure occurred. Postoperatively the patient experienced disturbed vision caused by bilateral retinal hemorrhages, and an iatrogenic Terson syndrome was diagnosed. The pathogenesis of Terson syndrome is discussed based on this illustrative case.

  5. Minimally invasive (endoscopic-computer assisted) surgery: Technique and review

    OpenAIRE

    Kumar, Anand; Yadav, Nirma; Singh, Shipra; Chauhan, Neha

    2016-01-01

    Endoscopic or minimally invasive surgery popular as keyhole surgery is a medical procedure in which endoscope (a camera) is used, and it has gained broad acceptance with popularity in several surgical specialties and has heightened the standard of care. Oral and maxillofacial surgery is a modern discipline in the field of dentistry in which endoscopy has developed as well as widely used in surgeries and is rapidly gaining importance. The use of different visual as well as standard instruments...

  6. Endoscopic classification of representations of quasi-split unitary groups

    CERN Document Server

    Mok, Chung Pang

    2015-01-01

    In this paper the author establishes the endoscopic classification of tempered representations of quasi-split unitary groups over local fields, and the endoscopic classification of the discrete automorphic spectrum of quasi-split unitary groups over global number fields. The method is analogous to the work of Arthur on orthogonal and symplectic groups, based on the theory of endoscopy and the comparison of trace formulas on unitary groups and general linear groups.

  7. Electromagnetic Compatibility in Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Ewing, P.D.; Kercel, S.W.; Korsah, K.; Wood, R.T.

    1999-08-29

    Electromagnetic compatibility (EMC) has long been a key element of qualification for mission critical instrumentation and control (I&C) systems used by the U.S. military. The potential for disruption of safety-related I&C systems by electromagnetic interference (EMI), radio-frequency interference (RFI), or power surges is also an issue of concern for the nuclear industry. Experimental investigations of the potential vulnerability of advanced safety systems to EMI/RFI, coupled with studies of reported events at nuclear power plants (NPPs) that are attributed to EMI/RFI, confirm the safety significance of EMC for both analog and digital technology. As a result, Oak Ridge National Laboratory has been engaged in the development of the technical basis for guidance that addresses EMC for safety-related I&C systems in NPPs. This research has involved the identification of engineering practices to minimize the potential impact of EMI/RFI and power surges and an evaluation of the ambient electromagnetic environment at NPPs to tailor those practices for use by the nuclear industry. Recommendations for EMC guidance have been derived from these research findings and are summarized in this paper.

  8. [Safety and electromagnetic compatibility in sanitary field].

    Science.gov (United States)

    Bini, M; Feroldi, P; Ferri, C; Ignesti, A; Olmi, R; Priori, S; Riminesi, C; Tobia, L

    2012-01-01

    In sanitary field and especially in a hospital, multiple sources of non ionizing radiation are used for diagnostic and therapeutic aims. In sanitary sector both workers and users are present at the same time, and in some cases general population could need higher protection than workers in relationship to the exposition to electromagnetic fields. In order to protect health and safety of patients, general population and workers of hospitals and with the aim to identify, analyze, evaluate and study its level of significance, electrical, magnetic and electromagnetic sources Research Italian project Si.C.E.O. (Safety And Electromagnetic Compatibility In Sanitary Field) was instituted. Target of our research project was to deepen risk of exposition elements with analysis of outdoor (e.g. power lines, transmission cabinets) and indoor (e.g. equipment for physical therapy) sources, located in sanitary structures and to verify the level exposition of workers and common population end the respect of specific regulation, and finally to define technical and organizational measures really useful for protection and reduction of risk.

  9. A magnetic field compatible graphene transmon

    Science.gov (United States)

    Kroll, James G.; Uilhoorn, Willemijn; de Jong, Damaz; Borsoi, Francesco; van der Enden, Kian; Goswami, Srijit; Cassidy, Maja; Kouwenhoven, Leo. P.

    Hybrid circuit QED is a key tool for readout and scaling of both semiconductor-based spin and topological quantum computing schemes. However, traditional approaches to circuit QED are incompatible with the strong external magnetic fields required for these qubits. Here we present measurements of a hybrid graphene-based transmon operating at 1 T. The device consists of coplanar waveguide resonators where the NbTiN thin film is patterned with a dense anti-dot lattice to trap Abriskov vortices, resulting in internal quality factors Qi >10^5 up to 6 T. Furthermore, the atomically thin nature of graphene in combination with the high critical field of its superconducting contacts makes it an ideal system for tolerating strong parallel magnetic fields. We combine these circuit elements to realize a magnetic field compatible transmon qubit. An external gate allows us to change the Josephson energy, and study the corresponding change in the resonator-qubit interaction in the dispersive regime. Two tone spectroscopy reveals a gate-tunable qubit peak at 1T. These experiments open up the possibility of fast charge parity measurements in high magnetic fields for readout of Majorana qubits..

  10. MRI compatible head phantom for ultrasound surgery.

    Science.gov (United States)

    Menikou, Georgios; Dadakova, Tetiana; Pavlina, Matt; Bock, Michael; Damianou, Christakis

    2015-03-01

    Develop a magnetic resonance imaging (MRI) compatible head phantom with acoustic attenuation closely matched to the human attenuation, and suitable for testing focused ultrasound surgery protocols. Images from an adult brain CT scan were used to segment the skull bone from adjacent cerebral tissue. The segmented model was manufactured in a 3-D printer using (Acrylonitrile Butadiene Styrene) ABS plastic. The cerebral tissue was mimicked by an agar-evaporated milk-silica gel (2% w/v-25% v/v-1.2% w/v) which was molded inside a skull model. The measured attenuation of the ABS skull was 16 dB/cm MHz. The estimated attenuation coefficient of the gel replicating brain tissue was 0.6 dB/cm MHz. The estimated agar-silica gel's T1 and T2 relaxation times in a 1.5 Tesla magnetic field were 852 ms and 66 ms respectively. The effectiveness of the skull to reduce ultrasonic heating was demonstrated using MRI thermometry. Due to growing interest in using MRI guided focused ultrasound (MRgFUS) for treating brain cancer and its application in sonothrombolysis, the proposed head phantom can be utilized as a very useful tool for evaluating ultrasonic protocols, thus minimizing the need for animal models and cadavers. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Matrix compatible solid phase microextraction coating, a greener approach to sample preparation in vegetable matrices.

    Science.gov (United States)

    Naccarato, Attilio; Pawliszyn, Janusz

    2016-09-01

    This work proposes the novel PDMS/DVB/PDMS fiber as a greener strategy for analysis by direct immersion solid phase microextraction (SPME) in vegetables. SPME is an established sample preparation approach that has not yet been adequately explored for food analysis in direct immersion mode due to the limitations of the available commercial coatings. The robustness and endurance of this new coating were investigated by direct immersion extractions in raw blended vegetables without any further sample preparation steps. The PDMS/DVB/PDMS coating exhibited superior features related to the capability of the external PDMS layer to protect the commercial coating, and showed improvements in terms of extraction capability and in the cleanability of the coating surface. In addition to having contributed to the recognition of the superior features of this new fiber concept before commercialization, the outcomes of this work serve to confirm advancements in the matrix compatibility of the PDMS-modified fiber, and open new prospects for the development of greener high-throughput analytical methods in food analysis using solid phase microextraction in the near future. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Amplitude-modulated fiber-ring laser

    DEFF Research Database (Denmark)

    Caputo, J. G.; Clausen, Carl A. Balslev; Sørensen, Mads Peter

    2000-01-01

    Soliton pulses generated by a fiber-ring laser are investigated by numerical simulation and perturbation methods. The mathematical modeling is based on the nonlinear Schrödinger equation with perturbative terms. We show that active mode locking with an amplitude modulator leads to a self-starting......Soliton pulses generated by a fiber-ring laser are investigated by numerical simulation and perturbation methods. The mathematical modeling is based on the nonlinear Schrödinger equation with perturbative terms. We show that active mode locking with an amplitude modulator leads to a self......-starting of stable solitonic pulses from small random noise, provided the modulation depth is small. The perturbative analysis leads to a nonlinear coupled return map for the amplitude, phase, and position of the soliton pulses circulating in the fiber-ring laser. We established the validity of this approach...

  13. Endoscopic therapy for gastrointestinal bleeding after liver transplantation

    Directory of Open Access Journals (Sweden)

    LIU Bo

    2016-10-01

    Full Text Available Objective To investigate the clinical effect of endoscopic therapy for patients with esophagogastric variceal bleeding (EVB after liver transplantation. Methods A retrospective analysis was performed for the clinical data of 8 patients who experienced EVB after liver transplantation and underwent endoscopic therapy, especially endoscopic features. The clinical outcome was evaluated, including hemostasis rate, change in varicose veins after treatment, and short-term recurrence and bleeding rate. Results The eight patients had a mean age of 55.00(44.75-61.50 years, and the mean time from liver transplantation to bleeding was 71.50(18.75-107.25 months. As for primary diseases, 6 patients had hepatitis B cirrhosis (among whom one patient each was complicated by liver cancer, alcoholic cirrhosis, and acute liver necrosis, and three were complicated by subacute liver necrosis, one had hepatitis C cirrhosis, and one had unexplained liver cirrhosis. Of all patients, 2 underwent sclerotherapy, 6 underwent endoscopic variceal ligation, and 6 underwent tissue adhesive treatment. The endoscopic therapy achieved successful hemostasis in all patients. No patients experienced rebleeding at discharge or the 12-month follow-up visit. One patient underwent selective endoscopic therapy due to the recurrence of varices. Conclusion Gastrointestinal bleeding remains a serious complication after liver transplantation. Besides antiviral therapy, the presence of varices should be closely monitored.

  14. Outcomes following Purely Endoscopic Endonasal Resection of Pituitary adenomas

    Directory of Open Access Journals (Sweden)

    Rezaul Amin

    2013-01-01

    Full Text Available Background: The use of endoscope for the management of pituitary adenoma is not new. The better magnification and illumination provided by the endoscope gives better outcome than microscopic pituitary surgery. Objective: To find out the benefits of endoscope in relation to microscopic surgery. Materials and Methods: We performed 45 cases of pituitary adenoma surgery by endoscopic endonasal approach from July 2008 to July 2010. Results: Forty five cases underwent endoscopic transsphenoidal approach. Gross total removal was done in 35 cases and subtotal removal was done in 10 cases. Residual tumours were seen in 10 cases (22% in postoperative follow-up MRI scan. Visual improvement was satisfactory, and hormonal improvement of functional adenoma was nice. Postoperative visual acuity and visual field were improved in 75% cases. There were 37% cases of temporary diabetes insipidus and about 4.5% cases of permanent diabetes insipidus. The average duration of follow-up was 20 months. One patient required reexploration to correct visual deterioration in the immediate postoperative period. There were 4.5% cases of CSF leak and 6.6% mortality. Mortality was due to electrolyte imbalance and improper management of infection and hydrocephalus. Conclusion: Endoscopic endonasal pituitary surgery now has become a gold standard surgery for most of the pituitary adenomas because of its better advantages in relation to microscopic surgery and less complications and less hospital stay.

  15. Endoscopic Therapeutic Approach for Dysplasia in Inflammatory Bowel Disease.

    Science.gov (United States)

    Hong, Sung Noh

    2017-09-01

    Long-standing intestinal inflammation in patients with inflammatory bowel disease (IBD) induces dysplastic change in the intestinal mucosa and increases the risk of subsequent colorectal cancer. The evolving endoscopic techniques and technologies, including dye spraying methods and high-definition images, have been replacing random biopsies and have been revealed as more practical and efficient for detection of dysplasia in IBD patients. In addition, they have potential usefulness in detailed characterization of lesions and in the assessment of endoscopic resectability. Most dysplastic lesions without an unclear margin, definite ulceration, non-lifting sign, and high index of malignant change with suspicion for lymph node or distant metastases can be removed endoscopically. However, endoscopic resection of dysplasia in chronic IBD patients is usually difficult because it is often complicated by submucosal fibrosis. In patients with dysplasias that demonstrate submucosa fibrosis or a large size (≥20 mm), endoscopic submucosal dissection (ESD) or ESD with snaring (simplified or hybrid ESD) is an alternative option and may avoid a colectomy. However, a standardized endoscopic therapeutic approach for dysplasia in IBD has not been established yet, and dedicated specialized endoscopists with interest in IBD are needed to fully investigate recent emerging techniques and technologies.

  16. [Treatment of pain in chronic pancreatitis by an endoscopic method].

    Science.gov (United States)

    Seicean, Andrada; Burtin, Pascal; Boyer, Jean; Pascu, Oliviu

    2002-06-01

    The epigastric pain is the most frequent manifestation in chronic pancreatitis. It is due to intraductal pancreatic pressure, presence of compressive pseudocysts and probably to neuroinflammatory process caused by alcohol. The aim of our study was to assess the influence of endoscopic treatment on pain in chronic pancreatitis and the correlation between residual pain after endoscopic treatment and pancreatic morphology. Forty-four patients from the Gastroenterology Department of Angers (France) with chronic pancreatitis were included in our retrospective clinical study. Thirty-seven patients underwent a diagnostic ERCP and only 28 needed an endoscopic treatment. The pain was evaluated semi-quantitatively before and after the endoscopic treatment. The mean follow-up was 28.6 months. Among the 28 patients with endoscopic treatment, 18 had a complete improvement of the pain, 4 an incomplete improvement and 6 had no improvement; these last were submitted to pancreatic surgery. The pain evolution had a good correlation with the reduction of Wirsung diameter; there was no correlation with ductal stenosis, residual lithiasis and pseudocysts presence. Alcohol consumption had no influence on the pain evolution. The endoscopic treatment of intraductal lithiasis and pseudocysts is a useful method for Wirsung decompression, improving the pain in chronic pancreatitis.

  17. Postoperative seizure following transforaminal percutaneous endoscopic lumbar discectomy

    Science.gov (United States)

    Kertmen, Hayri; Gürer, Bora; Yilmaz, Erdal Resit; Sekerci, Zeki

    2016-01-01

    Endoscopic surgery for lumbar disc herniation has been available for more than 30 years. Transforaminal percutaneous endoscopic lumbar discectomy is a well-known, safe, and effective method used for the treatment of the lumbar disc herniation. The published complications of the transforaminal percutaneous endoscopic lumbar discectomy consist of infections, thrombophlebitis, dysesthesia, dural tear, vascular injury, and death. Seizure after transforaminal percutaneous endoscopic lumbar discectomy is an extremely rare complication. A 20-year-old patient applied at our department who had undergone transforaminal percutaneous endoscopic lumbar. During the procedure, while performing the discography, non-ionic contrast media was administered into the thecal sac inadvertently. Two hours after surgery, the patient developed generalized tonic-clonic seizure of 5-min duration. Diagnosis of iohexol-induced seizure was made and the patient was treated supportively without anti-epileptics. Here we present the first case of seizure after transforaminal percutaneous endoscopic lumbar discectomy, which was caused by inadvertent administration of the contrast media into the thecal sac. PMID:27695562

  18. Refractory gastric antral vascular ectasia: a new endoscopic approach.

    Science.gov (United States)

    Zulli, C; Del Prete, A; Romano, M; Esposito, F; Amato, M R; Esposito, P

    2015-11-01

    Gastric antral vascular ectasia (GAVE) is an uncommon disorder observed in patients with liver cirrhosis, causing upper gastro-intestinal haemorrhage. GAVE is diagnosed through esophagogastroduodenoscopy and is characterized by the presence of visible columns of red tortuous enlarged vessels along the longitudinal folds of the antrum (i.e., so-called watermelon stomach). Pharmacological, endoscopic and surgical approaches have been proposed for the treatment of GAVE. Endoscopy represents the gold standard for GAVE treatment. The most widely used endoscopic approach is represented by Neodymium:yttrium-aluminum-garnet (Nd:YAG) laser. Argon plasma coagulation (APC) has been proven to be more efficient in terms of costs and complication rates than and equally effective as Nd:YAG. Other endoscopic procedures proposed for this treatment are banding ligature (EBL) and sclerotherapy with Polidocanol. Refractory GAVE represents a therapeutic challenge because it may cause persistent anemia, often leading to repeated blood transfusions due to the inefficacy of pharmacological and endoscopic therapeutic approaches. Endoscopic band ligation (EBL) has been shown to be superior to APC in the treatment of refractory GAVE. Surgical antrectomy by Billroth I anastomosis can be considered in selected cases. In this study, we report a successful endoscopic treatment of refractory GAVE by using a combination of submucosal injection of 1% Polidocanol at the four antral quadrants and subsequent application of APC on the visible antral lesions in two patients.

  19. Endoscopic features of gastrointestinal tuberculosis and crohn's disease

    Directory of Open Access Journals (Sweden)

    Praneeth Moka

    2017-01-01

    Full Text Available Endoscopic examination of the gastrointestinal (GI tract plays a very important role in the diagnosis and follow-up of patients with Crohn's disease (CD and intestinal tuberculosis (TB. The clinical, morphological, and histological features of GI TB and CD are so similar that it becomes difficult to differentiate between these two entities. In geographical regions such as India where both GI TB and CD are prevalent, differential diagnosis between the two is challenging. While there is a lot of similarities between these two disorders, these two can be differentiated from each other with a combination of clinical, endoscopic, histological, radiological, and endoscopic features. The observation of the characteristic lesions at endoscopic examination and the extent of involvement in CD and intestinal TB is an important step in differentiation between these two disorders. While the most important endoscopic characteristics such as involvement of left side of the colon and presence of longitudinal ulcerations and cobblestoning support a diagnosis of CD, predominant involvement of ileocecal region and transverse ulcers support the diagnosis of intestinal TB. In this review, we have described the usefulness and limitations of endoscopic modalities in the diagnosis and differentiation of intestinal TB and CD.

  20. Endoscopical appearances of nonsteroidal anti inflammatory drug (NSAID- enteropathy

    Directory of Open Access Journals (Sweden)

    Marcellus Simadibrata

    2005-12-01

    Full Text Available Non Steroidal Anti Inflammatory Drugs (NSAID have been associated with a sudden and sustained rise in the incidence of gastrointestinal ulcer complications. The aim of the study was to reveal the endoscopical abnormalities found in the duodenum & proximal jejunum due to NSAID. Thirty eight patients taking NSAID for their arthritis or rheumatism were included in this study. Gastro-duodeno-jejunoscopy was done with Olympus PCF-10. The endoscopical appearances of NSAID entero gastropathy were evaluated with a scoring system. The NSAID-entero-gastropathy appearances were endoscopically seen as hyperemia, erosion and ulcer. From all patient recruited, 7.9% complaint of diarrhea and 71.1% complaint of dyspepsia. Endoscopically, in the duodenal bulb we found 79% cases of hyperemia, 39.5% cases of erosion and 7.9% cases of ulcer. In the second part (descending part of the duodenum we found 28.9% cases of hyperemia, 15.8% cases of erosion and 2.6% case of ulcer. In the jejunum, we found 7.9% cases of hyperemia, 2.6% case of erosion and no ulcer. It is concluded that the most frequent abnormal endoscopical appearances in NSAID- enteropathy was hyperemia. The most frequent site of NSAID-enteropathy abnormal findings was in the duodenal bulb. (Med J Indones 2005; 14: 225-9Keywords: NSAID-enteropathy, endoscopical appearances.