WorldWideScience

Sample records for endoscopic ultrasound guided

  1. [Endoscopic ultrasound guided rendezvous for biliary drainage].

    Science.gov (United States)

    Knudsen, Marie Høxbro; Vilmann, Peter; Hassan, Hazem; Karstensen, John Gésdal

    2015-04-27

    Endoscopic retrograde cholangiography (ERCP) is currently standard treatment for biliary drainage. Endoscopic ultrasound guided rendezvous (EUS-RV) is a novel method to overcome an unsuccessful biliary drainage procedure. Under endoscopic ultrasound guidance a guidewire is passed via a needle from the stomach or duodenum to the common bile duct and from there on to the duodenum enabling ERCP. With a relatively high rate of success EUS-RV should be considered as an alternative to biliary drainage and surgical intervention.

  2. Endoscopic Ultrasound-Guided Biliary Drainage

    International Nuclear Information System (INIS)

    Artifon, Everson L.A.; Ferreira, Fla'vio C.; Sakai, Paulo

    2012-01-01

    To demonstrate a comprehensive review of published articles regarding endoscopic ultrasound (EUS)-guided biliary drainage. Review of studies regarding EUS-guided biliary drainage including case reports, case series and previous reviews. EUS-guided hepaticogastrostomy, coledochoduodenostomy and choledoantrostomy are advanced biliary and pancreatic endoscopy procedures, and together make up the echo-guided biliary drainage. Hepaticogastrostomy is indicated in cases of hilar obstruction, while the procedure of choice is the coledochoduodenostomy or choledochoantrostomy in distal lesions. Both procedures must be performed only after unsuccessful ERCPs. The indication of these procedures must be made under a multidisciplinary view while sharing information with the patient or legal guardian. Hepaticogastrostomy and coledochoduodenostomy or choledochoantrostomy are feasible when performed by endoscopists with expertise in biliopancreatic endoscopy. Advanced echo-endoscopy should currently be performed under a rigorous protocol in educational institutions.

  3. Endoscopic Ultrasound-Guided Biliary Drainage

    Energy Technology Data Exchange (ETDEWEB)

    Artifon, Everson L.A.; Ferreira, Fla& #x27; vio C.; Sakai, Paulo [University of Saeo Paulo, Saeo Paulo (Brazil)

    2012-02-15

    To demonstrate a comprehensive review of published articles regarding endoscopic ultrasound (EUS)-guided biliary drainage. Review of studies regarding EUS-guided biliary drainage including case reports, case series and previous reviews. EUS-guided hepaticogastrostomy, coledochoduodenostomy and choledoantrostomy are advanced biliary and pancreatic endoscopy procedures, and together make up the echo-guided biliary drainage. Hepaticogastrostomy is indicated in cases of hilar obstruction, while the procedure of choice is the coledochoduodenostomy or choledochoantrostomy in distal lesions. Both procedures must be performed only after unsuccessful ERCPs. The indication of these procedures must be made under a multidisciplinary view while sharing information with the patient or legal guardian. Hepaticogastrostomy and coledochoduodenostomy or choledochoantrostomy are feasible when performed by endoscopists with expertise in biliopancreatic endoscopy. Advanced echo-endoscopy should currently be performed under a rigorous protocol in educational institutions.

  4. Ultrasound-guided endoscopic transgastric drainage of a post ...

    African Journals Online (AJOL)

    Despite of a number of techniques in the armentarium of the paediatric surgeon, the management of pancreatic pseudocysts remains a challenge. We report on a case of a 5-year-old child with a post-traumatic pancreatic pseudocyst who was successfully treated with endoscopic ultrasound-guided transgastric approach.

  5. Practice guidelines for endoscopic ultrasound-guided celiac plexus neurolysis

    DEFF Research Database (Denmark)

    Wyse, Jonathan M; Battat, Robert; Sun, Siyu

    2017-01-01

    OBJECTIVES: The objective of guideline was to provide clear and relevant consensus statements to form a practical guideline for clinicians on the indications, optimal technique, safety and efficacy of endoscopic ultrasound guided celiac plexus neurolysis (EUS-CPN). METHODS: Six important clinical...

  6. Practice guidelines for endoscopic ultrasound-guided celiac plexus neurolysis

    NARCIS (Netherlands)

    Wyse, J.M. (Jonathan M.); Battat, R. (Robert); Sun, S. (Siyu); A. Saftoiu (Adrian); Siddiqui, A.A. (Ali A.); Leong, A.T. (Ang Tiing); Arias, B.L.A. (Brenda Lucia Arturo); Fabbri, C. (Carlo); Adler, D.G. (Douglas G.); Santo, E. (Erwin); Kalaitzakis, E. (Evangelos); Artifon, E. (Everson); Mishra, G. (Girish); Okasha, H.H. (Hussein Hassan); J.-W. Poley (Jan-Werner); Guo, J. (Jintao); Vila, J.J. (Juan J.); Lee, L.S. (Linda S.); Sharma, M. (Malay); Bhutani, M.S. (Manoop S.); M. Giovannini (Marcello); Kitano, M. (Masayuki); Eloubeidi, M.A. (Mohamad Ali); Khashab, M.A. (Mouen A.); Nguyen, N.Q. (Nam Q.); Saxena, P. (Payal); Vilmann, P. (Peter); Fusaroli, P. (Pietro); Garg, P.K. (Pramod Kumar); Ho, S. (Sammy); Mukai, S. (Shuntaro); Carrara, S. (Silvia); Sridhar, S. (Subbaramiah); S. Lakhtakia (S.); Rana, S.S. (Surinder S.); Dhir, V. (Vinay); Sahai, A.V. (Anand V.)

    2017-01-01

    textabstractObjectives: The objective of guideline was to provide clear and relevant consensus statements to form a practical guideline for clinicians on the indications, optimal technique, safety and efficacy of endoscopic ultrasound guided celiac plexus neurolysis (EUS-CPN). Methods: Six important

  7. Endoscopic ultrasound-guided transmural drainage of postoperative pancreatic collections.

    Science.gov (United States)

    Tilara, Amy; Gerdes, Hans; Allen, Peter; Jarnagin, William; Kingham, Peter; Fong, Yuman; DeMatteo, Ronald; D'Angelica, Michael; Schattner, Mark

    2014-01-01

    Pancreatic leak is a major cause of morbidity after pancreatectomy. Traditionally, peripancreatic fluid collections have been managed by percutaneous or operative drainage. Data for endoscopic ultrasound (EUS)-guided drainage of postoperative fluid collections are limited. Here we report on the safety, efficacy, and timing of EUS-guided drainage of postoperative peripancreatic collections. This is a retrospective review of 31 patients who underwent EUS-guided drainage of fluid collections after pancreatic resection. Technical success was defined as successful transgastric deployment of at least one double pigtail plastic stent. Clinical success was defined as resolution of the fluid collection on follow-up CT scan and resolution of symptoms. Early drainage was defined as initial transmural stent placement within 30 days after surgery. Endoscopic ultrasound-guided drainage was performed effectively with a technical success rate of 100%. Clinical success was achieved in 29 of 31 patients (93%). Nineteen of the 29 patients (65%) had complete resolution of their symptoms and collection with the first endoscopic procedure. Repeat drainage procedures, including some with necrosectomy, were required in the remaining 10 patients, with eventual resolution of collection and symptoms. Two patients who did not achieve durable clinical success required percutaneous drainage by interventional radiology. Seventeen (55%) of 31 patients had successful early drainage completed within 30 days of their operation. Endoscopic ultrasound-guided drainage of fluid collections after pancreatic resection is safe and effective. Early drainage (collections was not associated with increased complications in this series. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Endoscopic ultrasound-guided hepaticogastrostomy for advanced cholangiocarcinoma after failed stenting by endoscopic retrograde cholangiopancreatography

    Directory of Open Access Journals (Sweden)

    Sukij Panpimanmas

    2013-10-01

    Conclusion: Endoscopic-ultrasound-guided hepaticogastrostomy is safe and can be a good palliative option for advanced malignant biliary obstruction because it drains internally and is remote from the tumor site, promoting a long patency period of prosthesis and better quality of life.

  9. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology

    DEFF Research Database (Denmark)

    Dumonceau, J-M; Polkowski, M; Larghi, A

    2011-01-01

    This article is part of a combined publication that expresses the current view of the European Society of Gastrointestinal Endoscopy (ESGE) about endoscopic ultrasound (EUS)-guided sampling in gastroenterology, including EUS-guided fine needle aspiration (EUS-FNA) and EUS-guided trucut biopsy (EU...

  10. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology

    DEFF Research Database (Denmark)

    Dumonceau, Jean-Marc; Deprez, Pierre H; Jenssen, Christian

    2017-01-01

    For pancreatic solid lesions, ESGE recommends performing endoscopic ultrasound (EUS)-guided sampling as first-line procedure when a pathological diagnosis is required. Alternatively, percutaneous sampling may be considered in metastatic disease.Strong recommendation, moderate quality evidence.In ...

  11. Endoscopic ultrasound-guided radiofrequency ablation of the pancreas

    DEFF Research Database (Denmark)

    Silviu, Ungureanu Bogdan; Daniel, Pirici; Claudiu, Mărgăritescu

    2015-01-01

    ultrasound (EUS)-guided radiofrequency ablation (RFA) probe through a 19G needle in order to achieve a desirable necrosis area in the pancreas. Radiofrequency ablation of the head of the pancreas was performed on 10 Yorkshire pigs with a weight between 25 kg and 35 kg and a length of 40-70 cm. Using an EUS...... analysis revealed increased values of amylase, alkaline phosphatase, and gamma-glutamyl transpeptidase on the 3rd day but a decrease on the 5th day. After necropsy and isolation of the pancreas, the ablated area was easily found, describing a solid necrosis. The pathological examination revealed...

  12. Safe and successful endoscopic initial treatment and long-term eradication of gastric varices by endoscopic ultrasound-guided Histoacryl (N-butyl-2-cyanoacrylate) injection

    OpenAIRE

    Gubler, Christoph; Bauerfeind, Peter

    2014-01-01

    OBJECTIVE: Optimal endoscopic treatment of gastric varices is still not standardized nowadays. Actively bleeding varices may prohibit a successful endoscopic injection therapy of Histoacryl® (N-butyl-2-cyanoacrylate). Since 2006, we have treated gastric varices by standardized endoscopic ultrasound (EUS) guided Histoacryl injection therapy without severe adverse events. MATERIAL AND METHODS: We present a large single-center cohort over 7 years with a standardized EUS-guided sclerotherapy o...

  13. Failed common bile duct cannulation during pregnancy: Rescue with endoscopic ultrasound guided rendezvous procedure.

    Science.gov (United States)

    Singla, Vikas; Arora, Anil; Tyagi, Pankaj; Sharma, Praveen; Bansal, Naresh; Kumar, Ashish

    2016-01-01

    Common bile duct (CBD) stones can lead to serious complications and require intervention with either endoscopic retrograde cholangiopancreatography (ERCP) or laparoscopic techniques for urgent relief. On an average 10%-20% of the patients with gall bladder stones can have associated CBD stones. CBD stones during pregnancy can be associated with hazardous complications for both the mother and the fetus. Failed cannulation while performing ERCP during pregnancy is a technically demanding situation, which requires immediate rescue with special techniques. Conventional rescue techniques may not be feasible and can be associated with hazardous consequences. Endoscopic ultrasound (EUS) guided rendezvous technique has now emerged as a safe alternative, and in one of our patients, this technique was successfully attempted. To the best of our knowledge, this is the first case report in the literature on EUS-guided rendezvous procedure during pregnancy.

  14. Endoscopic Ultrasound-guided Drainage of Pancreatic Pseudocysts

    DEFF Research Database (Denmark)

    Ng, Pui Yung; Nytoft Rasmussen, Ditlev; Vilmann, Peter

    2013-01-01

    or by telephonic interview. RESULTS: A total of 61 procedures were performed. The symptoms that indicated drainage were abdominal pain (n = 43), vomiting (n = 7) and jaundice (n = 5). The procedure was technically successful in 57 of the 61 procedures (93%). The immediate complication rate was 5%. At a mean follow......-up of 45 weeks, the treatment success was 75%. The medium term complications appeared in 25% of cases, which included three cases each of stent clogging, stent migration, infection and six cases of recurrence. There was no mortality. CONCLUSION: EUS-guided drainage is an effective treatment for PPC...... with a successful outcome in most of patients. Most of the complications require minimal invasive surgical treatment or repeated EUS-guided drainage procedures....

  15. Endoscopic ultrasound-guided fine-needle tissue acquisition - A review and update of literature

    Directory of Open Access Journals (Sweden)

    Benjamin Tharian

    2015-01-01

    Full Text Available Ever since the first endoscopic ultrasound-guided fine needle aspiration (FNA was done in 1992, the procedure has evolved to become an indispensable tool for tissue acquisition in patients with gastrointestinal tumors and periluminal lesions. With the growing evidence of neoadjuvant therapy and research into intratumoral therapy, the need to obtain tissue diagnosis for tumors is quite apparent. This review provides an overall perspective to the endosonographer on various issues that are a key for best practices in FNA, in addition to being an update for practicing experienced endosonographers.

  16. Endoscopic ultrasound guided biopsy performed routinely in lung cancer staging spares futile thoracotomies

    DEFF Research Database (Denmark)

    Larsen, Soeren S; Vilmann, Peter; Krasnik, Mark

    2005-01-01

    BACKGROUND: Up to 45% of operations with curative intent for non-small-cell lung cancer (NSCLC) can be regarded as futile, apparently because the stage of the disease is more advanced than expected preoperatively. During the past decade several studies have evaluated the usefulness of endoscopic...... ultrasound guided fine needle aspiration biopsy (EUS-FNA) in lung cancer staging with promising results. However, no randomised trials have been performed, in which a staging strategy with EUS-FNA performed in all patients is compared with a conventional workup. METHODS: Before surgery (i.e. mediastinoscopy...

  17. Asian EUS Cup-05: Successful management of peripancreatic tumors by endoscopic ultrasound-guided radiofrequency ablation

    OpenAIRE

    Oh, Dongwook; Seo, Dong Wan

    2017-01-01

    Background: Endoscopic ultrasound-guided radiofrequency ablation (EUS-RFA) could be used as an effective alternative treatment for peripancreatic tumor. Herein, we reported a case of adrenal adenoma which was treated by EUS-RFA. Case Report: A 38-year-old woman presented with ?moon face,? ?buffalo hump,? and weight gain of 9 kg in 12 months. Initial contrast-enhanced abdominal computed tomography showed a 2.8 cm left adrenal mass, and the patient was diagnosed with Cushing?s syndrome due to l...

  18. Endoscopic Ultrasound-Guided Perirectal Abscess Drainage without Drainage Catheter: A Case Series

    Directory of Open Access Journals (Sweden)

    Eun Kwang Choi

    2017-05-01

    Full Text Available A perirectal abscess is a relatively common disease entity that occurs as a postsurgical complication or as a result of various medical conditions. Endoscopic ultrasound (EUS-guided drainage was recently described as a promising alternative treatment. Previous reports have recommended placement of a drainage catheter through the anus for irrigation, which is inconvenient to the patient and carries a risk of accidental dislodgement. We report four cases of perirectal abscess that were successfully treated with only one or two 7 F double pigtail plastic stent placements and without a drainage catheter for irrigation.

  19. A novel lumen-apposing metal stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections

    DEFF Research Database (Denmark)

    Walter, Daisy; Will, Uwe; Sanchez-Yague, Andres

    2015-01-01

    BACKGROUND AND STUDY AIMS: A novel large-diameter, lumen-apposing, self-expanding metal stent with bilateral flanges was recently developed for endoscopic ultrasound (EUS)-guided transmural drainage of symptomatic pancreatic fluid collections (PFCs). The aim of this study was to evaluate the effi......BACKGROUND AND STUDY AIMS: A novel large-diameter, lumen-apposing, self-expanding metal stent with bilateral flanges was recently developed for endoscopic ultrasound (EUS)-guided transmural drainage of symptomatic pancreatic fluid collections (PFCs). The aim of this study was to evaluate...

  20. Endoscopic Ultrasound-guided Rendezvous Technique after Failed Endoscopic Retrograde Cholangiopancreatography: Which Approach Route Is the Best?

    Science.gov (United States)

    Okuno, Nozomi; Hara, Kazuo; Mizuno, Nobumasa; Hijioka, Susumu; Tajika, Masahiro; Tanaka, Tsutomu; Ishihara, Makoto; Hirayama, Yutaka; Onishi, Sachiyo; Niwa, Yasumasa; Yamao, Kenji

    2017-12-01

    Objective The endoscopic ultrasound-guided rendezvous technique (EUS-RV) is a salvage method for failed selective biliary cannulation. Three puncture routes have been reported, with many comparisons between the intra-hepatic and extra-hepatic biliary ducts. We used the trans-esophagus (TE) and trans-jejunum (TJ) routes. In the present study, the utility of EUS-RV for biliary access was evaluated, focusing on the approach routes. Methods and Patients In 39 patients, 42 puncture routes were evaluated in detail. EUS-RV was performed between January 2010 and December 2014. The patients were prospectively enrolled, and their clinical data were retrospectively collected. Results The patients' median age was 71 (range 29-84) years. The indications for endoscopic retrograde cholangiopancreatography (ERCP) were malignant biliary obstruction in 24 patients and benign biliary disease in 15. The technical success rate was 78.6% (33/42) and was similar among approach routes (p=0.377). The overall complication rate was 16.7% (7/42) and was similar among approach routes (p=0.489). However, mediastinal emphysema occurred in 2 TE route EUS-RV patients. No EUS-RV-related deaths occurred. Conclusion EUS-RV proved reliable after failed ERCP. The selection of the appropriate route based on the patient's condition is crucial.

  1. Clinical utility of an endoscopic ultrasound-guided rendezvous technique via various approach routes.

    Science.gov (United States)

    Kawakubo, Kazumichi; Isayama, Hiroyuki; Sasahira, Naoki; Nakai, Yousuke; Kogure, Hirofumi; Hamada, Tsuyoshi; Miyabayashi, Koji; Mizuno, Suguru; Sasaki, Takashi; Ito, Yukiko; Yamamoto, Natsuyo; Hirano, Kenji; Tada, Minoru; Koike, Kazuhiko

    2013-09-01

    The endoscopic ultrasound-guided rendezvous techniques (EUS-rendezvous) provide reliable biliary access after failed endoscopic retrograde cholangiopancreatography (ERCP) cannulation. We evaluated the clinical utility of an EUS-rendezvous technique using various approach routes. Patients undergoing EUS-rendezvous for biliary access after failed bile duct cannulation in ERCP were included. EUS-rendezvous was performed via three approach routes depending on the patient's condition: transgastric, transduodenal in a short endoscopic position, or transduodenal in a long endoscopic position. The main outcomes were the technical success rates. Secondary outcomes were procedure time and complications. Fourteen patients (median age, 77 years) underwent EUS-rendezvous for biliary access resulting from failed biliary cannulation. The reasons for biliary drainage were malignant biliary obstruction in five patients and choledocholithiasis in nine. Transgastric, transduodenal in a short position, and transduodenal in a long position EUS-rendezvous was performed in five, five, and four patients, respectively. Bile duct puncture occurred in the left intrahepatic duct in four patients, right hepatic duct in one, middle common bile duct in four, and lower common bile duct in five. The technical success rate was 100 %. In four patients, the approach route was modified from transduodenal in a short position to transduodenal in a long position or transgastric route. The median procedure time was 81 min. One case each of biliary peritonitis and pancreatitis occurred and were managed conservatively. EUS-rendezvous provided safe and reliable transpapillary bile duct access after failed ERCP cannulation. The selection of the appropriate approach routes, depending on patient condition, is critical.

  2. Alleviating Pancreatic Cancer-Associated Pain Using Endoscopic Ultrasound-Guided Neurolysis

    Science.gov (United States)

    Takenaka, Mamoru; Kamata, Ken; Yoshikawa, Tomoe; Nakai, Atsushi; Omoto, Shunsuke; Miyata, Takeshi; Yamao, Kentaro; Imai, Hajime; Sakamoto, Hiroki; Kitano, Masayuki; Kudo, Masatoshi

    2018-01-01

    The most common symptom in patients with advanced pancreatic cancer is abdominal pain. This has traditionally been treated with nonsteroidal anti-inflammatory drugs and opioid analgesics. However, these treatments result in inadequate pain control or drug-related adverse effects in some patients. An alternative pain-relief modality is celiac plexus neurolysis, in which the celiac plexus is chemically ablated. This procedure was performed percutaneously or intraoperatively until 1996, when endoscopic ultrasound (EUS)-guided celiac plexus neurolysis was first described. In this transgastric anterior approach, a neurolytic agent is injected around the celiac trunk under EUS guidance. The procedure gained popularity as a minimally invasive approach and is currently widely used to treat pancreatic cancer-associated pain. We focus on two relatively new techniques of EUS-guided neurolysis: EUS-guided celiac ganglia neurolysis and EUS-guided broad plexus neurolysis, which have been developed to improve efficacy. Although the techniques are safe and effective in general, some serious adverse events including ischemic and infectious complications have been reported as the procedure has gained widespread popularity. We summarize reported clinical outcomes of EUS-guided neurolysis in pancreatic cancer (from the PubMed and Embase databases) with a goal of providing information useful in developing strategies for pancreatic cancer-associated pain alleviation. PMID:29462851

  3. Endoscopic ultrasound-guided evaluation of the pleura and cases of pleural effusion.

    Science.gov (United States)

    Sharma, Malay; Rameshbabu, Chittapuram Srinivasan

    2017-01-01

    The most efficient and cost-effective approach for the diagnosis of pleural exudates remains uncertain and is a subject of controversy. Essential factors to be considered include the respective diagnostic yields of thoracocentesis, closed pleural biopsy, and thoracoscopy. The role of endoscopic ultrasound (EUS) of the esophagus as a modality for the evaluation of pleural exudates has not yet been evaluated. The applied anatomy of the pleura has been discussed. The techniques involved in the EUS imaging of different aspects of the pleura in normal cases and in cases with pleural effusion are elaborated. The practical application of this knowledge can be useful in EUS-guided sampling of the pleural wall, pleural nodules, and in cases of pleural effusion.

  4. Nonfluoroscopic endoscopic ultrasound-guided transmural drainage of pancreatic pseudocysts at atypical locations

    Directory of Open Access Journals (Sweden)

    Surinder Singh Rana

    2016-01-01

    Full Text Available Background: Pancreatic pseudocysts (PP at atypical locations are a therapeutic challenge and are usually managed surgically. Objective: We evaluated safety and efficacy of nonfluoroscopic endoscopic ultrasound (NF-EUS-guided transmural drainage in the management of PP at atypical locations. Patients and Methods: Retrospective analysis of 11 patients (all males; age range: 28-46 years with PP at atypical locations who were treated with NF-EUS-guided transmural drainage during the last 18 months was done. Results: Four patients had intra/peri-splenic, three patients had mediastinal, three patients had intrahepatic, and one patient had renal PP. Nine patients had chronic pancreatitis whereas two patients had acute pancreatitis. Alcohol was the etiology of pancreatitis in ten patients. The size of PP ranged from 4 to 10 cm. All patients had abdominal pain, and two patients had fever whereas one patient with mediastinal PP also had dysphagia. NF-EUS-guided transmural drainage could be done successfully in all patients. 7 Fr transmural stent (s was/were placed in six patients whereas single-time complete aspiration of PP was done in five patients. On endoscopic retrograde pancreatography, six patients had partial duct disruption whereas five patients had complete disruption. Bridging transpapillary stent (5 Fr was placed in all patients with partial disruption. All PP healed in 10/11 (91% patients within 2-4 weeks, and there has been no recurrence in 9 of these patients during a follow-up period of 4-18 months. One patient with splenic PP needed surgery for gastrointestinal bleed. Conclusion: PP at atypical locations can be effectively and safely treated with NF-EUS-guided transmural drainage.

  5. Infectious peritonitis after endoscopic ultrasound-guided biliary drainage in a patient with ascites

    Directory of Open Access Journals (Sweden)

    Nozomi Okuno

    2018-04-01

    Full Text Available Summary of Event: Bacterial, mycotic peritonitis and Candida fungemia developed in a patient with moderate ascites who had undergone endoscopic ultrasound-guided biliary drainage (EUS-BD. Antibiotics and antifungal agent were administered and ascites drainage was performed. Although the infection improved, the patient’s general condition gradually deteriorated due to aggravation of the primary cancer and he died.Teaching Point: This is the first report to describe infectious peritonitis after EUS-BD. Ascites carries the potential risk of severe complications. As such, in patients with ascites, endoscopic retrograde cholangiopancreatography (ERCP is typically preferred over EUS-BD or percutaneous drainage to prevent bile leakage. However, ERCP may not be possible in some patients with tumor invasion of the duodenum or with surgically altered anatomy. Thus, in patients with ascites who require EUS-BD, we recommend inserting the drainage tube percutaneously and draining the ascites before and after the intervention in order to prevent severe infection.

  6. Usefulness of combined percutaneous-endoscopic rendezvous techniques after failed therapeutic endoscopic retrograde cholangiography in the era of endoscopic ultrasound guided rendezvous.

    Science.gov (United States)

    Yang, Min Jae; Kim, Jin Hong; Hwang, Jae Chul; Yoo, Byung Moo; Kim, Soon Sun; Lim, Sun Gyo; Won, Je Hwan

    2017-12-01

    The rendezvous approach is a salvage technique after failure of endoscopic retrograde cholangiography (ERC). In certain circumstances, percutaneous-endoscopic rendezvous (PE-RV) is preferred, and endoscopic ultrasound-guided rendezvous (EUS-RV) is difficult to perform. We aimed to evaluate PE-RV outcomes, describe the PE-RV techniques, and identify potential indications for PE-RV over EUS-RV.Retrospective analysis was conducted of a prospectively designed ERC database between January 2005 and December 2016 at a tertiary referral center including cases where PE-RV was used as a salvage procedure after ERC failure.During the study period, PE-RV was performed in 42 cases after failed therapeutic ERC; 15 had a surgically altered enteric anatomy. The technical success rate of PE-RV was 92.9% (39/42), with a therapeutic success rate of 88.1% (37/42). Potential indications for PE-RV over EUS-RV were identified in 23 cases, and either PE-RV or EUS-RV could have effectively been used in 19 cases. Endoscopic bile duct access was successfully achieved with PE-RV in 39 cases with accessible biliary orifice using one of PE-RV cannulation techniques (classic, n = 11; parallel, n = 19; and adjunctive maneuvers, n = 9).PE-RV uses a unique technology and has clinical indications that distinguish it from EUS-RV. Therefore, PE-RV can still be considered a useful salvage technique for the treatment of biliary obstruction after ERC failure.

  7. Endoscopic ultrasound-guided fine-needle aspiration cytology in the evaluation of suspected tuberculosis in patients with isolated mediastinal lymphadenopathy

    DEFF Research Database (Denmark)

    Puri, R.; Vilmann, P.; Sud, R.

    2010-01-01

    Patients with suspected tuberculosis without pulmonary lesions and with mediastinal lymphadenopathy often pose a diagnostic challenge. Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) cytology is an established modality to evaluate mediastinal and abdominal lesions. The aim...

  8. Endoscopic ultrasound-guided pancreaticobiliary intervention in patients with surgically altered anatomy and inaccessible papillae: A review of current literature

    Science.gov (United States)

    Martin, Aaron; Kistler, Charles Andrew; Wrobel, Piotr; Yang, Juliana F.; Siddiqui, Ali A.

    2016-01-01

    The management of pancreaticobiliary disease in patients with surgically altered anatomy is a growing problem for gastroenterologists today. Over the years, endoscopic ultrasound (EUS) has emerged as an important diagnostic and therapeutic modality in the treatment of pancreaticobiliary disease. Patient anatomy has become increasingly complex due to advances in surgical resection of pancreaticobiliary disease and EUS has emerged as the therapy of choice when endoscopic retrograde cholangiopancreatography failed cannulation or when the papilla is inaccessible such as in gastric obstruction or duodenal obstruction. The current article gives a comprehensive review of the current literature for EUS-guided intervention of the pancreaticobiliary tract in patients with altered surgical anatomy. PMID:27386471

  9. How to learn and to perform endoscopic ultrasound and endobronchial ultrasound for lung cancer staging

    DEFF Research Database (Denmark)

    Konge, Lars; Colella, Sara; Vilmann, Peter

    2015-01-01

    The learning of transesophageal ultrasound guided fine needle aspiration (FNA) (endoscopic ultrasound-FNA), and endobronchial ultrasound guided transbronchial needle aspiration (endosonography) should be based on the following steps: Acquiring theoretical knowledge, training on simulators, and su...

  10. Determination of optimal ultrasound planes for the initialisation of image registration during endoscopic ultrasound-guided procedures.

    Science.gov (United States)

    Bonmati, Ester; Hu, Yipeng; Gibson, Eli; Uribarri, Laura; Keane, Geri; Gurusami, Kurinchi; Davidson, Brian; Pereira, Stephen P; Clarkson, Matthew J; Barratt, Dean C

    2018-06-01

    Navigation of endoscopic ultrasound (EUS)-guided procedures of the upper gastrointestinal (GI) system can be technically challenging due to the small fields-of-view of ultrasound and optical devices, as well as the anatomical variability and limited number of orienting landmarks during navigation. Co-registration of an EUS device and a pre-procedure 3D image can enhance the ability to navigate. However, the fidelity of this contextual information depends on the accuracy of registration. The purpose of this study was to develop and test the feasibility of a simulation-based planning method for pre-selecting patient-specific EUS-visible anatomical landmark locations to maximise the accuracy and robustness of a feature-based multimodality registration method. A registration approach was adopted in which landmarks are registered to anatomical structures segmented from the pre-procedure volume. The predicted target registration errors (TREs) of EUS-CT registration were estimated using simulated visible anatomical landmarks and a Monte Carlo simulation of landmark localisation error. The optimal planes were selected based on the 90th percentile of TREs, which provide a robust and more accurate EUS-CT registration initialisation. The method was evaluated by comparing the accuracy and robustness of registrations initialised using optimised planes versus non-optimised planes using manually segmented CT images and simulated ([Formula: see text]) or retrospective clinical ([Formula: see text]) EUS landmarks. The results show a lower 90th percentile TRE when registration is initialised using the optimised planes compared with a non-optimised initialisation approach (p value [Formula: see text]). The proposed simulation-based method to find optimised EUS planes and landmarks for EUS-guided procedures may have the potential to improve registration accuracy. Further work will investigate applying the technique in a clinical setting.

  11. Endoscopic ultrasound-guided radiofrequency ablation for management of benign solid pancreatic tumors.

    Science.gov (United States)

    Choi, Jun-Ho; Seo, Dong-Wan; Song, Tae Jun; Park, Do Hyun; Lee, Sang Soo; Lee, Sung Koo; Kim, Myung-Hwan

    2018-05-04

     Radiofrequency ablation (RFA) has been increasingly employed in experimental and clinical settings for the management of pancreatic lesions. This study aimed to assess the safety and efficacy of endoscopic ultrasound (EUS)-guided RFA for benign solid pancreatic tumors.  In a single-center, prospective study, 10 patients with benign solid pancreatic tumors underwent EUS-RFA. After the RFA electrode had been inserted into the pancreatic mass, the radiofrequency generator was activated to deliver 50 W of ablation power.  Among the 10 patients, 16 sessions of EUS-RFA were successfully performed. Diagnoses included nonfunctioning neuroendocrine tumor (n = 7), solid pseudopapillary neoplasm (n = 2), and insulinoma (n = 1); the median largest diameter of the tumors was 20 mm (range 8 - 28 mm). During follow-up (median 13 months), radiologic complete response was achieved in seven patients. Two adverse events (12.4 %; 1 moderate and 1 mild) occurred.  EUS-RFA may be a safe and potentially effective treatment option in selected patients with benign solid pancreatic tumors. Multiple sessions may be required if there is a remnant tumor, and adverse events must be carefully monitored. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Endoscopic Ultrasound-Guided Biliary Drainage Using Self-Expandable Metal Stent for Malignant Biliary Obstruction

    Directory of Open Access Journals (Sweden)

    Lei Lu

    2017-01-01

    Full Text Available Purpose. Endoscopic ultrasound-guided biliary drainage (EUS-BD has been increasingly reported worldwide. However, studies concerning EUS-BD from Mainland China are sporadic. This study aims to investigate the feasibility, efficacy, and safety of EUS-BD using SEMS in a single center from Mainland China. Methods. Between November 2011 and August 2015, 24 patients underwent EUS-BD using a standardized algorithm. Results. Three patients underwent rendezvous technique (RV, 4 underwent hepaticogastrostomy (HGS, and 17 underwent choledochoduodenostomy (CDS. The technical and clinical success rates were 95.8% (23/24 and 100% (23/23, respectively. Mean procedure time for the CDS group (35.9 ± 5.0 min or HGS group (39.3 ± 5.0 min was significantly shorter than that for the RV group (64.7 ± 9.1 min (P<0.05. Complications (13% included (1 cholangitis and (2 postprocedure hemorrhage. During the follow-up periods (mean 6.4 months, 22 (91.7% patients died of tumor progression with mean stent patency of 5.8 ± 2.2 months. Stent occlusion occurred in 2 (8.7% patients. Conclusion. EUS-BD using SEMS is a feasible, effective, and safe alternative for biliary decompression after failed ERCP. EUS-RV may not be the first-line choice for EUS-BD in a medium volume center. Further evaluation and experience of this method are needed.

  13. Therapeutic aspects of endoscopic ultrasound

    Science.gov (United States)

    Woodward, Timothy A.

    1999-06-01

    Endoscopic ultrasound (EUS) is a technology that had been used primarily as a passive imaging modality. Recent advances have enabled us to move beyond the use of EUS solely as a staging tool to an interventional device. Current studies suggest that interventional applications of EUS will allow for minimally invasive assessment and therapies in a cost-effective manner. Endoscopic ultrasound with fine needle aspiration (EUS-FNA) has been demonstrated to be a technically feasible, relatively safe method of obtaining cytologic specimens. The clinical utility of EUS- FNA appears to be greatest in the diagnosis and staging of pancreatic cancer and in the nodal staging of gastrointestinal and pulmonary malignancies. In addition, EUS-FNA has demonstrated utility in the sampling pleural and ascitic fluid not generally appreciated or assessable to standard interventions. Interventional applications of EUS include EUS-guided pseudocyst drainage, EUS-guided injection of botulinum toxin in the treatment of achalasia, and EUS- guided celiac plexus neurolysis in the treatment of pancreatic cancer pain. Finally, EUS-guided fine-needle installation is being evaluated, in conjunction with recent bimolecular treatment modalities, as a delivery system in the treatment of certain gastrointestinal tumors.

  14. Safe and successful endoscopic initial treatment and long-term eradication of gastric varices by endoscopic ultrasound-guided Histoacryl (N-butyl-2-cyanoacrylate) injection.

    Science.gov (United States)

    Gubler, Christoph; Bauerfeind, Peter

    2014-09-01

    Optimal endoscopic treatment of gastric varices is still not standardized nowadays. Actively bleeding varices may prohibit a successful endoscopic injection therapy of Histoacryl® (N-butyl-2-cyanoacrylate). Since 2006, we have treated gastric varices by standardized endoscopic ultrasound (EUS) guided Histoacryl injection therapy without severe adverse events. We present a large single-center cohort over 7 years with a standardized EUS-guided sclerotherapy of all patients with gastric varices. Application was controlled by fluoroscopy to immediately detect any glue embolization. Only perforating veins located within the gastric wall were treated. In the follow up, we repeated this treatment until varices were eradicated. Utmost patients (36 of 40) were treated during or within 24 h of active bleeding. About 32.5% of patients were treated while visible bleeding. Histoacryl injection was always technically successful and only two patients suffered a minor complication. Acute bleeding was stopped in all patients. About 15% (6 of 40) of patients needed an alternative rescue treatment in the longer course. Three patients got a transjugular portosystemic shunt and another three underwent an orthotopic liver transplantation. Mean long-term survival of 60 months was excellent. Active bleeding of gastric varices can be treated successfully without the necessity of gastric rinsing with EUS-guided injection of Histoacryl.

  15. Endoscopic ultrasound guided injection of iron oxide magnetic nanoparticles for liver and pancreas

    DEFF Research Database (Denmark)

    Ungureanu, Bogdan Silviu; Pirici, Daniel; Margaritescu, Claudiu

    2016-01-01

    )-guidance, both systemically and locally in the liver and pancreas in order to study new potential therapies for liver and pancreatic tumors. MATERIAL AND METHODS: Six domestic pigs were used for our study design, and divided into three groups: two were injected in the portal vein, and other four were subjected...... to local exposure of IONs in the liver and pancreas, two each. The pigs were on a 7 days follow-up and necropsy was performed with their organs harvested. A 3T MRI scan was also performed. RESULTS: All animals underwent an endoscopic ultrasound fine needle injection (EUS-FNI) procedure without any...

  16. Relationship of pancreatic mass size and diagnostic yield of endoscopic ultrasound-guided fine needle aspiration.

    Science.gov (United States)

    Siddiqui, Ali A; Brown, Lauren J; Hong, Shih-Kuang S; Draganova-Tacheva, Rossitza A; Korenblit, Jason; Loren, David E; Kowalski, Thomas E; Solomides, Charalambos

    2011-11-01

    Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is central to discerning the diagnosis of solid pancreatic tumors through tissue acquisition. Test performance is affected by a number of factors including location of mass within the pancreas, presence of onsite cytology technologist, and number of passes with the needle. The influence of tumor size has not been well studied. The objective of the current study was to determine whether the size of mass affects the diagnostic accuracy for solid pancreatic lesions aspirated under EUS guidance. Data were collected retrospectively on all patients with solid pancreatic masses undergoing EUS-FNA from June 2003 to August 2010. The cytology samples were reported as positive, suspicious for malignancy, atypical, negative, or nondiagnostic. The gold standard for a cytological diagnosis was histological confirmation or clinical follow-up of more than 6 months with repeat imaging. Patients were divided into five groups based upon lesion size as follows: (a) less than 1 cm, (b) 1-2 cm, (c) 2-3 cm, (d) 3-4 cm, and (e) greater than 4 cm. Performance characteristics of EUS-FNA including sensitivity, specificity, and accuracy were compared for each group. Accuracy was defined as the ratio of the sum of true-positive and true-negative values divided by the number of lesions. We identified 583 patients with solid pancreatic lesions in which EUS-FNA was performed and adequate cellularity was obtained (47% men, mean age 65 ± 1.4 (SE) years). Overall, 486 (83%) of lesions were pancreatic adenocarcinoma, 18 (3%) were neuroendocrine tumors, 12 (2%) were lymphomas, and 67 (12%) were benign lesions. The median size of the mass was 3 cm (range, 0.5-7 cm). A mean of 4.9 passes (range, 1-9 passes) was needed to obtain adequate samples from lesions. The overall yield of obtaining adequate samples for diagnosis was 85%. When stratified by size, the EUS-FNA sensitivity for lesions with size 4 cm was 40, 75.9, 86.9, 93

  17. Endoscopic ultrasound-guided fine-needle aspiration cytology in the evaluation of suspected tuberculosis in patients with isolated mediastinal lymphadenopathy

    DEFF Research Database (Denmark)

    Puri, R.; Vilmann, P.; Sud, R.

    2010-01-01

    Patients with suspected tuberculosis without pulmonary lesions and with mediastinal lymphadenopathy often pose a diagnostic challenge. Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) cytology is an established modality to evaluate mediastinal and abdominal lesions. The aim...... of the present study was to evaluate the role of EUS-FNA in isolated mediastinal lymphadenopathy in patients suspected of having tuberculosis....

  18. Endoscopic Ultrasound-Guided Fine Needle Aspiration versus Percutaneous Ultrasound-Guided Fine Needle Aspiration in Diagnosis of Focal Pancreatic Masses.

    Science.gov (United States)

    Okasha, Hussein Hassan; Naga, Mazen Ibrahim; Esmat, Serag; Naguib, Mohamed; Hassanein, Mohamed; Hassani, Mohamed; El-Kassas, Mohamed; Mahdy, Reem Ezzat; El-Gemeie, Emad; Farag, Ali Hassan; Foda, Ayman Mohamed

    2013-10-01

    Pancreatic carcinoma is one of the leading cancer morbidity and mortality world-wide. Controversy has arisen about whether the percutaneous approach with computed tomography/ultrasonography-guidance fine needle aspiration (US-FNA) or endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the preferred method to obtain diagnostic tissue. Our purpose of this study is to compare between the diagnostic accuracy of EUS-FNA and percutaneous US-FNA in diagnosis of pancreatic cancer. A total of 197 patients with pancreatic masses were included in the study, 125 patients underwent US-FNA (Group 1) and 72 patients underwent EUS-FNA (Group 2). EUS-FNA has nearly the same accuracy (88.9%) as US-FNA (87.2%) in diagnosis of pancreatic cancer. The sensitivity, specificity, positive predictive value and negative predictive value for EUS-FNA was 84%, 100%, 100%, 73.3% respectively. It was 85.5%, 90.4%, 94.7%, 76% respectively for US-FNA. EUS-FNA had a lower complication rate (1.38%) than US-FNA (5.6%). EUS-FNA has nearly the same accuracy as US-FNA of pancreatic masses with a lower complication rate.

  19. Advances in the Management of Upper Gastrointestinal Subepithelial Tumor: Pathologic Diagnosis Using Endoscopy without Endoscopic Ultrasound-Guided Biopsy

    Directory of Open Access Journals (Sweden)

    Hang Lak Lee

    2016-05-01

    Full Text Available Until now, biopsy methods for subepithelial tumors (SETs have focused on endoscopic ultrasound (EUS-guided biopsy; however, these methods have several limitations. We devised a simple method for pathologic diagnosis of SETs. SETs are occasionally diagnosed during endoscopy, and lesions are generally small and asymptomatic. It can be challenging to decide on a management plan for large asymptomatic SETs. EUS imaging provides information regarding the size, layer, and echo pattern of the lesions. Patient management plans have traditionally been determined based on EUS images, whereby the endoscopist chooses to either monitor or remove the tumor. However, EUS alone cannot diagnose and evaluate upper gastrointestinal SETs with high accuracy. As sufficient tissue samples are required for the accurate diagnosis of SETs, EUS-guided biopsy techniques such as EUS fine-needle aspiration and trucut biopsy are currently used. However, these methods have a relatively low diagnostic accuracy and do not always provide information upon immunohistochemical staining. Endoscopists can easily detect a submucosal mass after creating an iatrogenic mucosal ulcer, after which tissue sampling is performed by using endoscopic biopsy. Furthermore, pathologic results can differentiate between benign and premalignant lesions. Here, we introduce a simple method for the pathologic diagnosis of SETs.

  20. Endoscopic Ultrasound Guided Rendezvous Drainage of Biliary Obstruction Using a New Flexible 19-Gauge Fine Needle Aspiration Needle.

    Science.gov (United States)

    Tang, Zhouwen; Igbinomwanhia, Efehi; Elhanafi, Sherif; Othman, Mohamed O

    2016-01-01

    Background and Aim. A successful endoscopic ultrasound guided rendezvous (EUS-RV) biliary drainage is dependent on accurate puncture of the bile duct and precise guide wire manipulation across the ampulla of Vater. We aim to study the feasibility of using a flexible 19-gauge fine aspiration needle in the performance of EUS-RV biliary drainage. Method. This is a retrospective case series of EUS-RV biliary drainage procedures at a single center. Patients who failed ERCP during the same session for benign or malignant biliary obstruction underwent EUS-RV using a flexible, nitinol covered, 19-gauge needle for biliary access and guide wire manipulation. Result. 24 patients underwent EUS-RV biliary drainage via extrahepatic access while 1 attempt was via intrahepatic access. The technical success rate was 80%, including 83.3% of cases via extrahepatic access. There was no significant difference in success rate of inpatient and outpatient procedures, benign or malignant indications, or type of guide wire used. Adverse events included mild pancreatitis (3 patients) and cholangitis (1 patient). Conclusion. A flexible 19-gauge needle for biliary access can be safe and effective when used to perform EUS-RV biliary drainage. Direct comparison between the nitinol needle and conventional metal needles in the performance of EUS guided biliary drainage is needed.

  1. A Comparison of Endoscopic Ultrasound Guided Biopsy and Positron Emission Tomography with Integrated Computed Tomography in Lung Cancer Staging

    DEFF Research Database (Denmark)

    Larsen, Stine Schmidt; Vilmann, P; Krasnik, K

    2009-01-01

    BACKGROUND AND STUDY AIMS: Exact staging of patients with non-small-cell lung cancer (NSCLC) is important to improve selection of resectable and curable patients for surgery. Positron emission tomography with integrated computed tomography (PET/CT) and endoscopic ultrasound guided fine needle...... aspiration biopsy (EUS-FNA) are new and promising methods, but indications in lung cancer staging are controversial. Only few studies have compared the 2 methods. The aim of this study was to assess and compare the diagnostic values of PET/CT and EUS-FNA for diagnosing advanced lung cancer in patients, who...... had both procedures performed. PATIENTS AND METHODS: 27 patients considered to be potential candidates for resection of NSCLC underwent PET/CT and EUS-FNA. Diagnoses were confirmed either by open thoracotomy, mediastinoscopy or clinical follow-up. Advanced lung cancer was defined as tumour...

  2. Endoscopic ultrasound-guided endoscopic transmural drainage of pancreatic pseudocysts Drenagem transmural de pseudocistos de pâncreas guiada por ecoendoscopia

    Directory of Open Access Journals (Sweden)

    César Vivian Lopes

    2008-03-01

    Full Text Available BACKGROUND: Surgery is the traditional treatment for symptomatic pancreatic pseudocysts, but the morbidity is still too high. Minimally invasive endoscopic approaches have been encouraged. AIMS: To evaluate the efficacy of endoscopic ultrasound-guided endoscopic transmural drainage of pancreatic pseudocysts. METHODS: From January, 2003 to August, 2006, 31 consecutive symptomatic patients submitted to 37 procedures at the same endoscopic unit were retrospectively analysed. Chronic and acute pancreatitis were found in, respectively, 17 (54.8% and 10 (32.3% cases. Bulging was present in 14 (37.8% cases. Cystogastrostomy or cystoduodenostomy were created with an interventional linear echoendoscope under endosonographic and fluoroscopic control. By protocol, only a single plastic stent, without nasocystic drain, was used. Straight or double pigtail stents were used in, respectively, 22 (59.5% and 15 (40.5% procedures. RESULTS: Endoscopic ultrasound-guided transmural drainage was successful in 29 (93.5% patients. Two cases needed surgery, both due to procedure-related complications. There was no mortality related to the procedure. Twenty-four patients were followed-up longer than 4 weeks. During a mean follow-up of 12.6 months, there were six (25% symptomatic recurrences due to stent clogging or migration, with two secondary infections. Median time for developing complications and recurrence of the collections was 3 weeks. These cases were successfully managed with new stents. Complications were more frequent in patients treated with straight stents and in those with a recent episode of acute pancreatitis. CONCLUSIONS: Endoscopic transmural drainage provides an effective approach to the management of pancreatic pseudocysts.RACIONAL: A abordagem cirúrgica é o tratamento tradicional para os pseudocistos sintomáticos de pâncreas, contudo a morbidade permanece elevada. Terapêuticas endoscópicas minimamente invasivas têm sido encorajadas. OBJETIVO

  3. A novel "hitch-and-ride" deep biliary cannulation method during rendezvous endoscopic ultrasound-guided ERCP technique.

    Science.gov (United States)

    Nakai, Yousuke; Isayama, Hiroyuki; Matsubara, Saburo; Kogure, Hirofumi; Mizuno, Suguru; Hamada, Tsuyoshi; Takahara, Naminatsu; Nakamura, Tomoka; Sato, Tatsuya; Takeda, Tsuyoshi; Hakuta, Ryunosuke; Ishigaki, Kazunaga; Saito, Kei; Tada, Minoru; Koike, Kazuhiko

    2017-10-01

    Background and study aim Endoscopic ultrasound-guided rendezvous (EUS-RV) is increasingly reported as a treatment option after failed endoscopic retrograde cholangiopancreatography. We developed a novel "hitch-and-ride" catheter for biliary cannulation to reduce the risk of guidewire loss during EUS-RV. Patients and methods We retrospectively evaluated safety and technical success of EUS-RV between June 2011 and May 2016. Biliary cannulation during EUS-RV using three methods - over-the-wire, along-the-wire, and hitch-and-ride - were compared. Results A total of 30 EUS-RVs were attempted and the technical success rate was 93.3 %, with two failures (one bile duct puncture and one guidewire insertion). After 28 cases of successful guidewire passage, cannulation was attempted by the over-the-wire (n = 13), along-the-wire (n = 4) or hitch-and-ride (n = 11) method. Only the hitch-and-ride method achieved biliary cannulation without guidewire loss or conversion to the other methods. Time to cannulation was shorter with the hitch-and-ride method (4 minutes) than with over-the-wire and along-the-wire methods (9 and 13 minutes, respectively). The adverse event rate of EUS-RV was 23.3 %. Conclusion A novel hitch-and-ride catheter was feasible for biliary cannulation after EUS-RV. © Georg Thieme Verlag KG Stuttgart · New York.

  4. INITIAL EXPERIENCE WITH ENDOSCOPIC ULTRASOUND-GUIDED FINE NEEDLE ASPIRATION OF RENAL MASSES: indications, applications and limitations

    Directory of Open Access Journals (Sweden)

    Renata Nobre MOURA

    2014-12-01

    Full Text Available Context Tissue sampling of renal masses is traditionally performed via the percutaneous approach or laparoscopicaly. The utility of endoscopic ultrasound to biopsy renal lesions it remains unclear and few cases have been reported. Objectives To evaluate the feasibility and outcome of endoscopic ultrasound fine needle aspiration of renal tumors. Methods Consecutive subjects undergoing attempted endoscopic ultrasound fine needle aspiration of a kidney mass after evaluation with computerized tomography or magnetic resonance. Results Ten procedures were performed in nine male patients (median age 54.7 years on the right (n = 4 and left kidney (n = 4 and bilaterally (n = 1. Kidney masses (median diameter 55 mm ; range 13-160 mm were located in the upper pole (n = 3, the lower pole (n = 2 and the mesorenal region (n = 3. In two cases, the mass involved more than one kidney region. Surgical resection confirmed renal cell carcinoma in six patients in whom pre-operative endoscopic ultrasound fine needle aspiration demonstrated renal cell carcinoma. No complications were reported. Conclusions Endoscopic ultrasound fine needle aspiration appears as a safe and feasible procedure with good results and minimal morbidity.

  5. Pancreatic metastases from ocular malignant melanoma: the use of endoscopic ultrasound-guided fine-needle aspiration to establish a definitive cytologic diagnosis: a case report

    Directory of Open Access Journals (Sweden)

    Diogo Turiani Hourneaux De Moura

    2016-12-01

    Full Text Available Abstract Background When encountering solid pancreatic lesions, nonpancreatic primary metastases are rare and differentiating a metastasis from a primary neoplastic lesion is challenging. The clinical presentation and radiologic features can be similar and the possibility of a pancreatic metastasis should be considered when the patient refers to a history of a different primary cancer. Endoscopic ultrasound offers a key anatomical advantage in accessing the pancreas and endoscopic ultrasound-guided fine-needle aspiration has become the gold standard method for diagnosing pancreatic lesions. Case presentation A 58-year-old white Hispanic woman with a history of uveal malignant melanoma, presented with abdominal pain and jaundice. On admission, laboratory tests were performed (her total bilirubin was 6.37 mg/dL with a direct fraction of 5.30 mg/dL. Cross-sectional, abdominal computed tomography with contrast, showed a low-attenuating lesion localized in the pancreatic head (measuring 4 × 3 cm and a thinner section of the distal bile duct suspicious for compression. Our patient was scheduled for an endoscopic ultrasound-guided fine-needle aspiration to establish a diagnosis. Endoscopic ultrasound showed a solid, hypoechoic, well-defined lesion with regular contours (measuring 3.17 × 2.61 cm, localized between the head and neck of the pancreas. Endoscopic ultrasound-guided fine-needle aspiration was performed with a 22G needle and cytology confirmed the diagnosis of metastatic melanoma. Our patient subsequently underwent right orbital exenteration, followed by duodenopancreatectomy without complications. At the moment our patient is receiving adjuvant chemotherapy at an outside oncology clinic. Conclusions To the best of our knowledge, this is a very rare presentation of an ocular malignant melanoma with an isolated pancreatic metastasis causing symptomatic biliary obstruction. Endoscopic ultrasound-guided fine-needle aspiration has

  6. Endoscopic ultrasound guided radiofrequency ablation, for pancreatic cystic neoplasms and neuroendocrine tumors

    Science.gov (United States)

    Pai, Madhava; Habib, Nagy; Senturk, Hakan; Lakhtakia, Sundeep; Reddy, Nageshwar; Cicinnati, Vito R; Kaba, Iyad; Beckebaum, Susanne; Drymousis, Panagiotis; Kahaleh, Michel; Brugge, William

    2015-01-01

    AIM: To outline the feasibility, safety, adverse events and early results of endoscopic ultrasound (EUS)-radiofrequency ablation (RFA) in pancreatic neoplasms using a novel probe. METHODS: This is a multi-center, pilot safety feasibility study. The intervention described was radiofrequency ablation (RF) which was applied with an innovative monopolar RF probe (1.2 mm Habib EUS-RFA catheter) placed through a 19 or 22 gauge fine needle aspiration (FNA) needle once FNA was performed in patients with a tumor in the head of the pancreas. The Habib™ EUS-RFA is a 1 Fr wire (0.33 mm, 0.013”) with a working length of 190 cm, which can be inserted through the biopsy channel of an echoendoscope. RF power is applied to the electrode at the end of the wire to coagulate tissue in the liver and pancreas. RESULTS: Eight patients [median age of 65 (range 27-82) years; 7 female and 1 male] were recruited in a prospective multicenter trial. Six had a pancreatic cystic neoplasm (four a mucinous cyst, one had intraductal papillary mucinous neoplasm and one a microcystic adenoma) and two had a neuroendocrine tumors (NET) in the head of pancreas. The mean size of the cystic neoplasm and NET were 36.5 mm (SD ± 17.9 mm) and 27.5 mm (SD ± 17.7 mm) respectively. The EUS-RFA was successfully completed in all cases. Among the 6 patients with a cystic neoplasm, post procedure imaging in 3-6 mo showed complete resolution of the cysts in 2 cases, whilst in three more there was a 48.4% reduction [mean pre RF 38.8 mm (SD ± 21.7 mm) vs mean post RF 20 mm (SD ± 17.1 mm)] in size. In regards to the NET patients, there was a change in vascularity and central necrosis after EUS-RFA. No major complications were observed within 48 h of the procedure. Two patients had mild abdominal pain that resolved within 3 d. CONCLUSION: EUS-RFA of pancreatic neoplasms with a novel monopolar RF probe was well tolerated in all cases. Our preliminary data suggest that the procedure is straightforward and safe. The

  7. Endoscopic Ultrasound-Guided Drainage of Intra-Abdominal Abscess after Gastric Perforation in a Patient Receiving Ramucirumab and Paclitaxel for Advanced Gastric Cancer

    Directory of Open Access Journals (Sweden)

    Koichiro Mandai

    2017-01-01

    Full Text Available Gastrointestinal perforation is a serious adverse event that occurs in approximately 1% of patients receiving ramucirumab and paclitaxel. A 67-year-old man with unresectable advanced gastric cancer was admitted to our hospital and treated with ramucirumab and paclitaxel. Gastric perforation occurred during the second cycle of chemotherapy. Although the patient’s condition improved without surgery, an abscess developed in the intra-abdominal fluid collection resulting from the perforation. We performed endoscopic ultrasound-guided abscess drainage. The patient improved and was discharged in satisfactory condition. Endoscopic ultrasound-guided drainage is a treatment option for patients with intra-abdominal abscess following gastric perforation due to ramucirumab.

  8. A comparison between endoscopic ultrasound-guided rendezvous and percutaneous biliary drainage after failed ERCP for malignant distal biliary obstruction.

    Science.gov (United States)

    Bill, Jason G; Darcy, Michael; Fujii-Lau, Larissa L; Mullady, Daniel K; Gaddam, Srinivas; Murad, Faris M; Early, Dayna S; Edmundowicz, Steven A; Kushnir, Vladimir M

    2016-09-01

    Selective biliary cannulation is unsuccessful in 5 % to 10 % of patients undergoing endoscopic retrograde cholangiopancreatography (ERCP) for malignant distal biliary obstruction (MDBO). Percutaneous biliary drainage (PBD) has been the gold standard, but endoscopic ultrasound guided rendezvous (EUSr) have been increasingly used for biliary decompression in this patient population. Our aim was to compare the initial success rate, long-term efficacy, and safety of PBD and EUSr in relieving MDBO after failed ERC Patients and methods: A retrospective study involving 50 consecutive patients who had an initial failed ERCP for MDBO. Twenty-five patients undergoing EUSr between 2008 - 2014 were compared to 25 patients who underwent PBD immediately prior to the introduction of EUSr at our center (2002 - 2008). Comparisons were made between the two groups with regard to technical success, duration of hospital stay and adverse event rates after biliary decompression. The mean age at presentation was 66.5 (± 12.6 years), 28 patients (54.9 %) were female. The etiology of MDBO was pancreaticobiliary malignancy in 44 (88 %) and metastatic disease in 6 (12 %) cases. Biliary drainage was technically successful by EUSr in 19 (76 %) cases and by PBD in 25 (100 %) (P = 0.002). Median length of hospital stay after initial drainage was 1 day in the EUSr group vs 5 days in PBD group (P = 0.02). Repeat biliary intervention was required for 4 patients in the EUSr group and 15 in the PBD group (P = 0.001). Initial technical success with EUSr was significantly lower than with PBD, however when EUSr was successful, patients had a significantly shorter post-procedure hospital stay and required fewer follow-up biliary interventions. Meeting presentations: Annual Digestive Diseases Week 2015.

  9. Endoscopic Ultrasound-Guided Rendezvous Technique for Failed Biliary Cannulation in Benign and Resectable Malignant Biliary Disorders.

    Science.gov (United States)

    Shiomi, Hideyuki; Yamao, Kentaro; Hoki, Noriyuki; Hisa, Takeshi; Ogura, Takeshi; Minaga, Kosuke; Masuda, Atsuhiro; Matsumoto, Kazuya; Kato, Hironari; Kamada, Hideki; Goto, Daisuke; Imai, Hajime; Takenaka, Mamoru; Noguchi, Chishio; Nishikiori, Hidefumi; Chiba, Yasutaka; Kutsumi, Hiromu; Kitano, Masayuki

    2018-03-01

    Endoscopic ultrasound-guided rendezvous technique (EUS-RV) has emerged as an effective salvage method for unsuccessful biliary cannulation. However, its application for benign and resectable malignant biliary disorders has not been fully evaluated. To assess the efficacy and safety of EUS-RV for benign and resectable malignant biliary disorders. This was a multicenter prospective study from 12 Japanese referral centers. Patients who underwent EUS-RV after failed biliary cannulation for biliary disorder were candidates for this study. Inclusion criteria were unsuccessful biliary cannulation for therapeutic endoscopic retrograde cholangiopancreatography with benign and potentially resectable malignant biliary obstruction. Exclusion criteria included unresectable malignant biliary obstruction, inaccessible papillae due to surgically altered upper gastrointestinal anatomy or duodenal stricture, and previous sphincterotomy and/or biliary stent placement. The primary outcome was the technical success rate of biliary cannulation; procedure time, adverse events, and clinical outcomes were secondary outcomes. Twenty patients were prospectively enrolled. The overall technical success rate and median procedure time were 85% and 33 min, respectively. Guidewire manipulation using a 4-Fr tapered tip catheter contributed to the success in advancing the guidewire into the duodenum. Adverse events were identified in 15% patients, including 2 with biliary peritonitis and 1 mild pancreatitis. EUS-RV did not affect surgical maneuvers or complications associated with surgery, or postoperative course. EUS-RV may be a safe and feasible salvage method for unsuccessful biliary cannulation for benign or resectable malignant biliary disorders. Use of a 4-Fr tapered tip catheter may improve the overall EUS-RV success rate.

  10. Endoscopic ultrasound-guided coil or glue injection in post-cyanoacrylate gastric variceal re-bleed.

    Science.gov (United States)

    Mukkada, Roy J; Antony, Rajesh; Chooracken, Mathew J; Francis, Jose V; Chettupuzha, Antony P; Mathew, Pradeep G; Augustine, Philip; Koshy, Abraham

    2018-04-09

    N-butyl-cyanoacrylate injection is recommended in bleeding/recently bled gastric varices. However, cyanoacrylate injection is associated with re-bleed in 25% to 50% of patients. Endoscopic ultrasound (EUS)-guided coil application is an emerging treatment modality for bleeding gastric varices. The aim of this study was to compare EUS-guided coil application combined with or without cyanoacrylate glue injection to injection alone in post-glue gastric variceal re-bleed. A retrospective analysis of a prospectively maintained database was performed. Thirty patients who re-bled after cyanoacrylate injection and who had EUS-guided coil application to gastric varices were included. The comparison was done with data of 51 patients who had only repeat cyanoacrylate injection. Both groups had a follow up for 12 months. EUS-guided coil application was done under endosonographic guidance. A single coil was placed in 7, two coils in each of 13 patients, three in 5, four in 3, five in one, and 6 coils in one patient. In addition, cyanoacrylate glue injection was given in 15 patients. Eight patients had repeat EUS-guided coil application 1 month later. Re-bleed and mortality were assessed. Coilng: Six out of 30 (20%) patients re-bled during follow up of 9 to 365 days. Three out of 30 (10%) died. One patient died 9 days after the procedure due to acute respiratory distress syndrome, one died 4 months after the procedure due to a re-bleed and one 5 months after the procedure due to spontaneous bacterial peritonitis. Glue only: 26/51 (51%) re-bled during follow up of 45 to 365 days. EUS-guided coil application resulted in significantly less re-bleed than glue-only (Kaplan-Meir survival analysis with log-rank test, z = 5.4, p guided coil application with/without cyanoacrylate injection for the obliteration of gastric varices is effective for post-cyanoacrylate gastric variceal re-bleed.

  11. The Utility of Endoscopic Ultrasound Guided Fine Needle Aspiration in the Diagnosis of Infectious Diseases—Report of Three Cases

    Directory of Open Access Journals (Sweden)

    Mauro Ajaj Saieg

    2013-01-01

    Full Text Available Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA is a fast and minimally invasive methodology with a crucial impact on patients’ management. It has an important and established role in the diagnosis and staging of mediastinal and abdominal malignancies, but little is discussed in the literature on the usefulness of this technique in the diagnosis of infectious diseases. In the current report, we present three different cases where EUS was essential for reaching the diagnosis of tuberculosis and paracoccidiodomicosis in cases otherwise seen as malignant. In conclusion, EUS was successful not only in obtaining enough cells for morphological analysis, but also for the production of cell blocks and assessment of the presence of the microorganisms by special stains. EUS allied to fine needle biopsy was an important tool in determining diagnoses of enlarged lymph nodes, revealing the diagnosis of infectious diseases in cases otherwise seen as malignant. The wide use of this methodology in cases such as those reported here cannot only rule out malignancy, but also aid critically ill patients by installing early proper therapy without the need for aggressive interventions.

  12. Eosinophilic esophageal myositis diagnosed by endoscopic ultrasound-guided fine-needle aspiration biopsy: a case report.

    Science.gov (United States)

    Igarashi, Ryo; Irisawa, Atsushi; Shibukawa, Goro; Yamabe, Akane; Fujisawa, Mariko; Sato, Ai; Maki, Takumi; Arakawa, Noriyuki; Yoshida, Yoshitsugu; Yamamoto, Shogo; Ikeda, Tsunehiko

    2016-10-01

    Eosinophilic esophagitis (EoE) is diagnosed by microscopic findings of eosinophilic infiltration into the squamous epithelium. In contrast, another disease concept termed "eosinophilic esophageal myositis (EoEM)" has been proposed, whereby there is eosinophilic infiltration into the muscularis propria instead. A 60-year-old man was referred to our hospital for chest pain, dysphagia, and several episodes of esophageal food impaction. Although EoE was suspected based on clinical features, biopsy specimens showed no mucosal eosinophilic infiltration. Endoscopic ultrasound (EUS) showed thickening of the muscularis propria layer and subsequent EUS-guided fine-needle aspiration biopsy (EUS-FNA) revealed eosinophilic infiltration into the muscularis propria. Although the patient's symptoms gradually improved after steroid administration, complete remission was not achieved after 1 year of treatment. This case may reflect a disorder distinct from typical EoE based on eosinophilic infiltration of the muscularis propria but not the squamous epithelium, and we, therefore, diagnosed it as EoEM using the EUS-FNA findings as reference.

  13. Role of endoscopic ultrasound-guided fine-needle aspiration in adrenal lesions: analysis of 32 patients

    Directory of Open Access Journals (Sweden)

    Rakesh K Gupta

    2018-01-01

    Full Text Available Objective: Endoscopic ultrasound-guided fine-needle aspiration cytology (EUS-FNAC is a precise and safe technique that provides both radiological and pathological diagnosis with a better diagnostic yield and minimal adverse events. EUS-FNAC led to the remarkable increase in the detection rate of incidentaloma found during radiologic staging or follow-up in various malignancy or unrelated conditions. Aims: We did this preliminary study with an aim to evaluate the role of EUS-FNA in diagnosing and classifying adrenal lesions, clinical impact, and compare the outcome with the previously published literature. Materials and Methods: We included 32 consecutive cases (both retrospective and prospective of EUS-guided adrenal aspirate performed over a period of 3.3 years. The indications for the aspirate in decreasing order were metastasis (most common carcinoma gall bladder > primary adrenal mass > disseminated tuberculosis > pyrexia of unknown origin. On EUS, 28 cases revealed space occupying lesion or mass (two cases bilateral and four cases revealed diffuse enlargement (two cases bilateral with a mean size of 21 mm. Results: The cytology reports were benign adrenal aspirate (43.8%, metastatic adenocarcinoma (15.6%, histoplasmosis (9.4%, tuberculosis (9.4%, round cell tumor (6.2%, adrenocortical carcinoma (3.1%, and descriptive (3.1%. Three cases (9.4% yielded inadequate sample. The TNM staging was altered in 22.23% of the cases by result of adrenal aspirate. Conclusions: EUS-FNA of the adrenal gland is a safe, quick, and sensitive and real-time diagnostic technique, which requires an integrated approach of clinician, endoscopist, and cytopathologist for high precision in diagnosis. Although the role of EUS-FNA for right adrenal is not much described, we found adequate sample yield in all the four patients that underwent the procedure.

  14. Comparison of 22G reverse-beveled versus standard needle for endoscopic ultrasound-guided sampling of solid pancreatic lesions

    Science.gov (United States)

    Alatawi, Abdullah; Beuvon, Frédéric; Grabar, Sophie; Leblanc, Sarah; Chaussade, Stanislas; Terris, Benoit; Barret, Maximilien

    2015-01-01

    Objectives Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using standard needles has a high diagnostic value in the evaluation of solid pancreatic masses. Fenestrated needles have been developed to improve the quality of EUS-guided tissue sampling by providing core biopsies (FNB). Methods Patients with solid pancreatic masses of >2 cm were prospectively included in our study and randomized to receive EUS sampling, using either a standard 22G FNA or a 22G Procore® FNB needle. The main study endpoint was the number of needle passes required to obtain a diagnosis in more than 90% of cases. Results We included 100 patients (male = 63, female = 37; mean age = 68.4 years) in our study. We found that 88% of the lesions were malignant, with a mean size of 32 mm. A sample adequate for diagnosis was obtained in more than 90% of cases after the second needle pass in the FNB group, versus the third needle pass in the FNA group. Slide cellularity and presence of tissue microfragments were significantly higher in the FNB group. Sensitivity for the diagnosis of malignancy was 88.4% versus 97.8% for the EUS-FNA and EUS-FNB group, respectively, while specificity for both techniques was 100%. No complications were recorded. Conclusions Although the accuracy of both needle types for proving malignancy was similar, a lower number of passes was required with the FNB needles to achieve the same contributive sample rate as with the FNA needles. FNB also improved the histopathological quality of specimens, suggesting an overall superiority of FNB sampling. PMID:26279842

  15. Comparison of diagnostic yield of endoscopic ultrasound-guided fine-needle aspiration cytology and cell block in solid lesions

    Directory of Open Access Journals (Sweden)

    Avinash Bhat Balekuduru

    2017-01-01

    Full Text Available Background and Aim: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA is a procedure of choice for the diagnostic evaluation of submucosal and periluminal lesions. Tissue sample can be obtained by EUS-FNA cytology (FNAC or cell block (CB. The aim of the present study is to compare diagnostic yield of EUS-FNA CB and cytology in the absence of onsite pathologist following a protocol-based EUS-FNA approach in solid lesions. Patients and Methods: Participants who underwent EUS-FNA at our center for solid submucosal or periluminal lesions (pancreas, lymph node, and liver between 2014 and 2016 were included, retrospectively. The indication for the procedure along with the clinical and other investigation details and the final etiological diagnosis were recorded on uniform structured data forms. The diagnostic yield of cytology and CB were compared using McNemar's test. The P < 0.05 was considered statistically significant. Results: EUS-FNA for solid lesion was performed in 130 lesions in 101 patients during the study period. Their mean age was 52.5 ± 12 years and 42.5% were female. Pancreatic masses were the most common lesions (37.7% followed by lymph nodes (36.9%. Submucosal lesions (17.7% and liver lesions (7.7% accounted for rest of the cases. The overall diagnostic yield for EUS-FNAC (70% and CB (74.6% was not significantly different (P = 0.3 and their combined yield was 85.3%. For the 23 patients with submucosal lesion, diagnostic yield of CB (82.6% was significantly better than cytology (47.8%, P = 0.04. Conclusions: EUS-guided CB has better yield compared to cytology in gastrointestinal submucosal lesions. The combination of CB with cytology improves the overall yield of the procedure; and hence, they should be considered complimentary rather than alternatives.

  16. Fluoroscopy-assisted vs fluoroless endoscopic ultrasound-guided transmural drainage of pancreatic fluid collections: A comparative study.

    Science.gov (United States)

    Consiglieri, Claudia F; Gornals, Joan B; Busquets, Juli; Peláez, Nuria; Secanella, Lluis; De-La-Hera, Meritxell; Sanzol, Resurrección; Fabregat, Joan; Castellote, José

    2018-01-01

    The need for fluoroscopy guidance in patients undergoing endoscopic ultrasound-guided transmural drainage (EUS-TMD) of peripancreatic fluid collections (PFCs) remains unclear. The aim of this study was to compare general outcomes of EUS-TMD of PFCs under fluoroscopy (F) vs fluoroless (FL). This is a comparative study with a retrospective analysis of a prospective and consecutive inclusion database at a tertiary centre, from 2009 to 2015. All patients were symptomatic pseudocyst (PSC) and walled-off pancreatic necrosis (WON). Two groups were assigned depending on availability of fluoroscopy. The groups were heterogeneous in terms of their demographic characteristics, PFCs and procedure. The main outcome measures included technical and clinical success, incidences, adverse events (AEs), and follow-up. Fifty EUS-TMD of PFCs from 86 EUS-guided drainages were included during the study period. Group F included 26 procedures, PSC 69.2%, WON 30.8%, metal stents 61.5% (46.1% lumen-apposing stent) and plastic stents 38.5%. Group FL included 24 procedures, PSC 37.5%, WON 62.5%, and metal stents 95.8% (lumen-apposing stents). Technical success was 100% in both groups, and clinical success was similar (F 88.5%, FL 87.5%). Technical incidences and intra-procedure AEs were only described in group F (7.6% and 11.5%, respectively) and none in group FL. Procedure time was less in group FL (8min, p=0.0341). Fluoroless in the EUS-TMD of PFCs does not involve more technical incidences or intra-procedure AEs. Technical and clinical success was similar in the two groups. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  17. Utilizing Endoscopic Ultrasound-Guided Fine Needle Aspiration in Identifying Molecular Targets for Pancreatic Cancer

    OpenAIRE

    Onyekachi Henry Ogbonna; Muhammad Wasif Saif

    2013-01-01

    Pancreatic cancer remains a devastating disease, with poor survival rates and high recurrence rates with current treatmentregimens. Over the years we have come to understand the complex biology of this cancer, involving cross-talking signalingpathways that proffers resistance to current therapy. Several molecularly targeted agents remain in development. At the2013 American Society of Clinical Oncology (ASCO) Annual Meeting, an abstract (#4051) was presented which exploredusing endoscopic ultr...

  18. Endoscopic ultrasound-guided fine-needle aspiration diagnosis of secondary tumors involving the pancreas: An institution′s experience

    Directory of Open Access Journals (Sweden)

    Ahmed K Alomari

    2016-01-01

    Full Text Available Background: Pancreatic masses may seldom represent a metastasis or secondary involvement by lymphoproliferative disorders. Recognition of this uncommon occurrence may help render an accurate diagnosis and avoid diagnostic pitfalls during endoscopic ultrasound-guided fine needle aspiration (EUS-FNA. In this study, we review our experience in diagnosing secondary tumors involving the pancreas. Materials and Methods: The electronic database of cytopathology archives was searched for cases of secondary tumors involving the pancreas at our institution and a total of 31 cases were identified. The corresponding clinical presentations, imaging study findings, cytological diagnoses, the results of ancillary studies, and surgical follow-up, if available, were reviewed. Results: Nineteen of the patients were male and 12 female, with a mean age of 66 years. Twenty-three patients (74% had a prior history of malignancy, with the latency ranging from 6 months to 19 years. The secondary tumors involving the pancreas included metastatic carcinoma (24 cases, metastatic sarcoma (3 cases, diffuse large B-cell lymphoma (2 cases, and plasma cell neoplasm (2 cases. The most common metastatic tumors were renal cell carcinoma (8 cases and lung carcinoma (7 cases. Correct diagnoses were rendered in 29 cases (94%. The remaining two cases were misclassified as primary pancreatic carcinoma. In both cases, the patients had no known history of malignancy, and no ancillary studies were performed. Conclusions: Secondary tumors involving the pancreas can be accurately diagnosed by EUS-FNA. Recognizing uncommon cytomorphologic features, knowing prior history of malignancy, and performing ancillary studies are the keys to improve diagnostic performance and avoid diagnostic pitfalls.

  19. Role of endoscopic ultrasound-guided fine needle aspiration and ultrasound-guided fine-needle aspiration in diagnosis of cystic pancreatic lesions

    Science.gov (United States)

    Okasha, Hussein Hassan; Ashry, Mahmoud; Imam, Hala M. K.; Ezzat, Reem; Naguib, Mohamed; Farag, Ali H.; Gemeie, Emad H.; Khattab, Hani M.

    2015-01-01

    Background and Objective: The addition of fine-needle aspiration (FNA) to different imaging modalities has raised the accuracy for diagnosis of cystic pancreatic lesions. We aim to differentiate benign from neoplastic pancreatic cysts by evaluating cyst fluid carcinoembryonic antigen (CEA), carbohydrate antigen (CA19-9), and amylase levels and cytopathological examination, including mucin stain. Patients and Methods: This prospective study included 77 patients with pancreatic cystic lesions. Ultrasound-FNA (US-FNA) or endoscopic ultrasound-FNA (EUS-FNA) was done according to the accessibility of the lesion. The aspirated specimens were subjected to cytopathological examination (including mucin staining), tumor markers (CEA, CA19-9), and amylase level. Results: Cyst CEA value of 279 or more showed high statistical significance in differentiating mucinous from nonmucinous lesions with sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of 73%, 60%, 50%, 80%, and 65%, respectively. Cyst amylase could differentiate between neoplastic and nonneoplastic cysts at a level of 1043 with sensitivity of 58%, specificity of 75%, PPV of 73%, NPV of 60%, and accuracy of 66%. CA19-9 could not differentiate between neoplastic and nonneoplastic cysts. Mucin examination showed a sensitivity of 85%, specificity of 95%, PPV of 92%, NPV of 91%, and accuracy of 91% in differentiating mucinous from non-mucinous lesions. Cytopathological examination showed a sensitivity of 81%, specificity of 94%, PPV of 94%, NPV of 83%, and accuracy of 88%. Conclusion: US or EUS-FNA with analysis of cyst CEA level, CA19-9, amylase, mucin stain, and cytopathological examination increases the diagnostic accuracy of cystic pancreatic lesions. PMID:26020048

  20. Endoscopic Ultrasound Elastography: Current Clinical Use in Pancreas.

    Science.gov (United States)

    Mondal, Utpal; Henkes, Nichole; Patel, Sandeep; Rosenkranz, Laura

    2016-08-01

    Elastography is a newer technique for the assessment of tissue elasticity using ultrasound. Cancerous tissue is known to be stiffer (hence, less elastic) than corresponding healthy tissue, and as a result, could be identified in an elasticity-based imaging. Ultrasound elastography has been used in the breast, thyroid, and cervix to differentiate malignant from benign neoplasms and to guide or avoid unnecessary biopsies. In the liver, elastography has enabled a noninvasive and reliable estimate of fibrosis. Endoscopic ultrasound has become a robust diagnostic and therapeutic tool for the management of pancreatic diseases. The addition of elastography to endoscopic ultrasound enabled further characterization of pancreas lesions, and several European and Asian studies have reported encouraging results. The current clinical role of endoscopic ultrasound elastography in the management of pancreas disorders and related literature are reviewed.

  1. Ultrasound guided supraclavicular block.

    LENUS (Irish Health Repository)

    Hanumanthaiah, Deepak

    2013-09-01

    Ultrasound guided regional anaesthesia is becoming increasingly popular. The supraclavicular block has been transformed by ultrasound guidance into a potentially safe superficial block. We reviewed the techniques of performing supraclavicular block with special focus on ultrasound guidance.

  2. Molecular Endoscopic Ultrasound for Diagnosis of Pancreatic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Bournet, Barbara [Department of Gastroenterology, University Hospital Center Rangueil, 1 avenue Jean Poulhès, TSA 50032, 31059 Toulouse Cedex 9 (France); INSERM U1037, University Hospital Center Rangueil, Toulouse (France); Pointreau, Adeline; Delpu, Yannick; Selves, Janick; Torrisani, Jerome [INSERM U1037, University Hospital Center Rangueil, Toulouse (France); Buscail, Louis, E-mail: buscail.l@chu-toulouse.fr [Department of Gastroenterology, University Hospital Center Rangueil, 1 avenue Jean Poulhès, TSA 50032, 31059 Toulouse Cedex 9 (France); INSERM U1037, University Hospital Center Rangueil, Toulouse (France); Cordelier, Pierre [INSERM U1037, University Hospital Center Rangueil, Toulouse (France)

    2011-02-24

    Endoscopic ultrasound-guided fine needle aspiration-biopsy is a safe and effective technique in diagnosing and staging of pancreatic ductal adenocarcinoma. However its predictive negative value does not exceed 50% to 60%. Unfortunately, the majority of pancreatic cancer patients have a metastatic and/or a locally advanced disease (i.e., not eligible for curative resection) which explains the limited access to pancreatic tissue specimens. Endoscopic ultrasound-guided fine needle aspiration-biopsy is the most widely used approach for cytological and histological material sampling in these situations used in up to two thirds of patients with pancreatic cancer. Based on this unique material, we and others developed strategies to improve the differential diagnosis between carcinoma and inflammatory pancreatic lesions by analysis of KRAS oncogene mutation, microRNA expression and methylation, as well as mRNA expression using both qRT-PCR and Low Density Array Taqman analysis. Indeed, differentiating pancreatic cancer from pseudotumoral chronic pancreatitis remains very difficult in current clinical practice, and endoscopic ultrasound-guided fine needle aspiration-biopsy analysis proved to be very helpful. In this review, we will compile the clinical and molecular advantages of using endoscopic ultrasound-guided fine needle aspiration-biopsy in managing pancreatic cancer.

  3. Molecular Endoscopic Ultrasound for Diagnosis of Pancreatic Cancer

    International Nuclear Information System (INIS)

    Bournet, Barbara; Pointreau, Adeline; Delpu, Yannick; Selves, Janick; Torrisani, Jerome; Buscail, Louis; Cordelier, Pierre

    2011-01-01

    Endoscopic ultrasound-guided fine needle aspiration-biopsy is a safe and effective technique in diagnosing and staging of pancreatic ductal adenocarcinoma. However its predictive negative value does not exceed 50% to 60%. Unfortunately, the majority of pancreatic cancer patients have a metastatic and/or a locally advanced disease (i.e., not eligible for curative resection) which explains the limited access to pancreatic tissue specimens. Endoscopic ultrasound-guided fine needle aspiration-biopsy is the most widely used approach for cytological and histological material sampling in these situations used in up to two thirds of patients with pancreatic cancer. Based on this unique material, we and others developed strategies to improve the differential diagnosis between carcinoma and inflammatory pancreatic lesions by analysis of KRAS oncogene mutation, microRNA expression and methylation, as well as mRNA expression using both qRT-PCR and Low Density Array Taqman analysis. Indeed, differentiating pancreatic cancer from pseudotumoral chronic pancreatitis remains very difficult in current clinical practice, and endoscopic ultrasound-guided fine needle aspiration-biopsy analysis proved to be very helpful. In this review, we will compile the clinical and molecular advantages of using endoscopic ultrasound-guided fine needle aspiration-biopsy in managing pancreatic cancer

  4. Clinical impact of endoscopic ultrasound-guided fine needle aspiration biopsy in patients with upper gastrointestinal tract malignancies. A prospective study

    DEFF Research Database (Denmark)

    Mortensen, M B; Pless, T; Durup, J

    2001-01-01

    BACKGROUND AND STUDY AIMS: Several studies have evaluated the accuracy of endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNAB) in the upper gastrointestinal tract, but so far no studies have specifically evaluated the clinical impact of EUS-FNAB in upper gastrointestinal tract......% in esophageal, gastric, and pancreatic cancer, respectively. The staging-related clinical impact was similar for all three types of cancer (11-12.5%), whereas the diagnosis-related impact was highest in pancreatic cancer patients (86%). EUS-FNAB was inadequate in 13% and gave false-negative results in 5......%. The overall sensitivity, specificity and accuracy for EUS-FNAB were 80%, 78% and 80%, respectively. No complications related to the biopsy procedure were seen. CONCLUSIONS: If EUS-FNAB was performed only in cases where a positive malignant result would change patient management, then approximately one out...

  5. Training in Endoscopy: Endoscopic Ultrasound

    Directory of Open Access Journals (Sweden)

    Chang Min Cho

    2017-07-01

    Full Text Available Endoscopic ultrasound (EUS has been recently established as an indispensable modality for the diagnosis and management of pancreatobiliary and gastrointestinal (GI disorders. EUS proficiency requires both cognitive and technical abilities, including an understanding of the appropriate indications, the performance of appropriate evaluations before and after the procedure, and the management of procedure-related complications. An increasing demand for skills to handle a growing range of interventional EUS procedures and a continual shortage of EUS training programs are two major obstacles for EUS training. Acquiring the skills necessary to comprehend and conduct EUS often requires training beyond the scope of a standard GI fellowship program. In addition to traditional formal EUS training and preceptorships, regular short-term intensive EUS training programs that provide training at various levels may help EUS practitioners improve and maintain EUS-related knowledges and skills. Theoretical knowledge can be acquired from lectures, textbooks, atlases, slides, videotapes, digital video discs, interactive compact discs, and websites. Informal EUS training is generally based on 1- or 2-day intensive seminars, including didactic lectures, skills demonstrated by expert practitioners through live video-streaming of procedures, and hands-on learning using animal or phantom models.

  6. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline - Updated January 2017.

    Science.gov (United States)

    Dumonceau, Jean-Marc; Deprez, Pierre H; Jenssen, Christian; Iglesias-Garcia, Julio; Larghi, Alberto; Vanbiervliet, Geoffroy; Aithal, Guruprasad P; Arcidiacono, Paolo G; Bastos, Pedro; Carrara, Silvia; Czakó, László; Fernández-Esparrach, Gloria; Fockens, Paul; Ginès, Àngels; Havre, Roald F; Hassan, Cesare; Vilmann, Peter; van Hooft, Jeanin E; Polkowski, Marcin

    2017-07-01

    For pancreatic solid lesions, ESGE recommends performing endoscopic ultrasound (EUS)-guided sampling as first-line procedure when a pathological diagnosis is required. Alternatively, percutaneous sampling may be considered in metastatic disease.Strong recommendation, moderate quality evidence.In the case of negative or inconclusive results and a high degree of suspicion of malignant disease, ESGE suggests re-evaluating the pathology slides, repeating EUS-guided sampling, or surgery.Weak recommendation, low quality evidence.In patients with chronic pancreatitis associated with a pancreatic mass, EUS-guided sampling results that do not confirm cancer should be interpreted with caution.Strong recommendation, low quality evidence.For pancreatic cystic lesions (PCLs), ESGE recommends EUS-guided sampling for biochemical analyses plus cytopathological examination if a precise diagnosis may change patient management, except for lesions ≤ 10 mm in diameter with no high risk stigmata. If the volume of PCL aspirate is small, it is recommended that carcinoembryonic antigen (CEA) level determination be done as the first analysis.Strong recommendation, low quality evidence.For esophageal cancer, ESGE suggests performing EUS-guided sampling for the assessment of regional lymph nodes (LNs) in T1 (and, depending on local treatment policy, T2) adenocarcinoma and of lesions suspicious for metastasis such as distant LNs, left liver lobe lesions, and suspected peritoneal carcinomatosis.Weak recommendation, low quality evidence.For lymphadenopathy of unknown origin, ESGE recommends performing EUS-guided (or alternatively endobronchial ultrasound [EBUS]-guided) sampling if the pathological result is likely to affect patient management and no superficial lymphadenopathy is easily accessible.Strong recommendation, moderate quality evidence.In the case of solid liver masses suspicious for metastasis, ESGE suggests performing EUS-guided sampling if the pathological result is likely

  7. Utility and Safety of Endoscopic Ultrasound With Bronchoscope-Guided Fine-Needle Aspiration in Mediastinal Lymph Node Sampling: Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Dhooria, Sahajal; Aggarwal, Ashutosh N; Gupta, Dheeraj; Behera, Digambar; Agarwal, Ritesh

    2015-07-01

    The use of endoscopic ultrasound with bronchoscope-guided fine-needle aspiration (EUS-B-FNA) has been described in the evaluation of mediastinal lymphadenopathy. Herein, we conduct a meta-analysis to estimate the overall diagnostic yield and safety of EUS-B-FNA combined with endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), in the diagnosis of mediastinal lymphadenopathy. The PubMed and EmBase databases were searched for studies reporting the outcomes of EUS-B-FNA in diagnosis of mediastinal lymphadenopathy. The study quality was assessed using the QualSyst tool. The yield of EBUS-TBNA alone and the combined procedure (EBUS-TBNA and EUS-B-FNA) were analyzed by calculating the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each study, and pooling the study results using a random effects model. Heterogeneity and publication bias were assessed for individual outcomes. The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was calculated using proportion meta-analysis. Our search yielded 10 studies (1,080 subjects with mediastinal lymphadenopathy). The sensitivity of the combined procedure was significantly higher than EBUS-TBNA alone (91% vs 80%, P = .004), in staging of lung cancer (4 studies, 465 subjects). The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was 7.6% in the diagnosis of mediastinal adenopathy. No serious complication of EUS-B-FNA procedure was reported. Clinical and statistical heterogeneity was present without any evidence of publication bias. Combining EBUS-TBNA and EUS-B-FNA is an effective and safe method, superior to EBUS-TBNA alone, in the diagnosis of mediastinal lymphadenopathy. Good quality randomized controlled trials are required to confirm the results of this systematic review. Copyright © 2015 by Daedalus Enterprises.

  8. Predictors of Malignancy and Recommended Follow-Up for Patients with Negative Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Suspected Pancreatic Lesions

    Directory of Open Access Journals (Sweden)

    Bret J Spier

    2009-01-01

    Full Text Available BACKGROUND: Endoscopic ultrasound (EUS with fine-needle aspiration (FNA can characterize and diagnose pancreatic lesions as malignant, but cannot definitively rule out the presence of malignancy. Outcome data regarding the length of follow-up in patients with negative or nondiagnostic EUS-FNA of pancreatic lesions are not well-established.

  9. EFSUMB Guidelines on Interventional Ultrasound (INVUS), Part IV - EUS-guided interventions

    DEFF Research Database (Denmark)

    Jenssen, C; Hocke, M; Fusaroli, P

    2016-01-01

    The fourth part of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) Guidelines on Interventional Ultrasound describes general aspects of endoscopic ultrasound-guided diagnostic and therapeutic interventions and assesses the evidence for endoscopic ultrasound-gu...

  10. Endoscopic ultrasound-guided pancreatic fluid collections' transmural drainage outcomes in 100 consecutive cases of pseudocysts and walled off necrosis: a single-centre experience from the United Kingdom.

    Science.gov (United States)

    Shekhar, Chander; Maher, Ben; Forde, Colm; Mahon, Brinder Singh

    2017-11-09

    Endoscopic ultrasound-guided drainage is a minimally invasive first-line modality for the drainage of pancreatic fluid collection (PFC) resulting in a shorter hospital stay and less morbidity compared with surgical cystogastrostomy. Our aim is to evaluate potential differences in the outcomes of endoscopic ultrasound (EUS) guided transmural drainage (EUS-TD) drainage of pancreatic pseudocyst (PP) and walled-off necrosis (WON). We retrospectively reviewed 100 consecutive EUS-guided drainages of PFC utilising EUS reports; clinical notes and imaging with follow-up (FU) to 12 months. All procedures were undertaken under conscious sedation with EUS guidance alone (without fluoroscopy) and placement of plastic double pigtail stents. In these 100 sequential cases, there were 78 cases of PP and 22 cases of WON. All 22/22(100%) cases of WON had successful EUS-guided stent placement. In 2/22(9%), there was little or no clinical improvement. These two patients required further computed tomography (CT)-guided drainage and one of these patients (1/22) (4.5%) developed recurrence within 12 months FU after removal of stents. In case of PP, overall stent placement was successful in 76/78 (97%) patients, but 6/78(8%) required 2nd EUS procedure after failure to show clinical improvement; 3/78(2.5%) required further CT-guided drainage. The overall complication rate was 9%(9/100) with 4%(4/100) requiring endoscopic or CT-guided intervention with no overall 30-day mortality. This is the largest series from a single UK centre demonstrating that EUS-guided cystogastrostomy of PFC drainage using plastic double pigtail stents is sufficient in majority of cases with PFC including that of WON, with or without infection.

  11. Endoscopic ultrasound and pancreas divisum

    DEFF Research Database (Denmark)

    Rana, Surinder S; Gonen, Can; Vilmann, Peter

    2012-01-01

    Pancreas divisum is the most common congenital anatomic variation of the pancreatic ductal anatomy and in most of the individuals it is asymptomatic. However, in minority of individuals it is presumed to cause recurrent acute pancreatitis and chronic pancreatitis. Endoscopic retrograde cholangiop......Pancreas divisum is the most common congenital anatomic variation of the pancreatic ductal anatomy and in most of the individuals it is asymptomatic. However, in minority of individuals it is presumed to cause recurrent acute pancreatitis and chronic pancreatitis. Endoscopic retrograde...... of the parenchyma also. Therefore EUS, both radial and linear, has potential for being a minimally invasive diagnostic modality for pancreas divisum. A number of EUS criteria have been suggested for the diagnosis of pancreas divisum. These criteria have varying sensitivity and specificity and hence there is a need...

  12. Endoscopic ultrasound-guided biliary drainage using a newly designed metal stent with a thin delivery system: a preclinical study in phantom and porcine models.

    Science.gov (United States)

    Minaga, Kosuke; Kitano, Masayuki; Itonaga, Masahiro; Imai, Hajime; Miyata, Takeshi; Yamao, Kentaro; Tamura, Takashi; Nuta, Junya; Warigaya, Kenji; Kudo, Masatoshi

    2017-12-08

    This study was designed to evaluate the feasibility and safety of a newly designed self-expandable metal stent for endoscopic ultrasound-guided biliary drainage (EUS-BD) when it was delivered via three different stent delivery systems: a 7.5Fr delivery catheter with a bullet-shaped tip (7.5Fr-bullet), a 7Fr catheter with a bullet-shaped tip (7Fr-bullet), or a 7Fr catheter with a tee-shaped tip (7Fr-tee). This experimental study utilized a porcine model of biliary dilatation involving ten pigs. In the animal study, technical feasibility and clinical outcomes of the stent when placed with each of the delivery systems were examined. In addition, a phantom model was used to measure the resistance of these delivery systems to advancement. Phantom experiments showed that, compared with 7Fr-bullet, 7Fr-tee had less resistance force to the advancement of the stent delivery system. EUS-BD was technically successful in all ten pigs. Fistulous tract dilation was necessary in 100% (2/2), 75% (3/4), and 0% (0/4) of the pigs that underwent EUS-BD using 7.5Fr-bullet, 7Fr-bullet, and 7Fr-tee, respectively. There were no procedure-related complications. Our newly designed metal stent may be feasible and safe for EUS-BD, particularly when delivered by 7Fr-tee, because it eliminates the need for fistulous tract dilation.

  13. Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis.

    Science.gov (United States)

    Oh, Hyoung-Chul; Kang, Hyun; Lee, Jae Young; Choi, Geun Joo; Choi, Jung Sik

    2016-11-01

    To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, -0.72; 95% CI, -1.02 to -0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.

  14. Identifying indications for percutaneous (PTC) vs. endoscopic ultrasound (EUS)- guided "rendezvous" procedure in biliary obstruction and incomplete endoscopic retrograde cholangiography (ERC).

    Science.gov (United States)

    Albert, J G; Finkelmeier, F; Friedrich-Rust, M; Kronenberger, B; Trojan, J; Zeuzem, S; Sarrazin, C

    2014-10-01

    The variety of rendezvous (RV) procedures has recently been extended by EUS- and PTCD-guided procedures as a complementary means to conventional ERCP. We have identified indication criteria and the potential of biliary PTCD-guided vs. EUS-guided RV. Consecutive patients with bile duct obstruction who underwent RV were included. In all, ERCP alone was unable to achieve treatment success. Indication, technical success, and outcome in PTCD- vs. EUS-guided RV were retrospectively compared to identify criteria that indicate preference of RV technique. Site of obstruction, clinical scenario (stenosis with abscess vs. no abscess) and reason for previous failure of ERC were evaluated. In 32 patients, three different indications for RV procedures were identified: First, a one-step access to assist in failed ERCP (type 1, intra-ductal RV); second, temporary drainage for prolonged treatment of complex biliary disease (type 2, intra-ductal RV), and drainage of cholangio-abscess with re-establishing bile outflow (type 3, intra-abscess RV). Indication of PTCD- vs. EUS-guided rendezvous was competitive in type 1, but exclusive in favor of PTCD in types 2 and 3. The site of biliary obstruction indicated the anatomic location of RV procedures. This classification may help to define inclusion criteria for prospective studies on biliary RV procedures. Choice of therapeutic strategy depends on the anatomic location of the biliary obstruction and the type of the biliary lesion. PTCD-guided RV might improve outcome in cholangio-abscess. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Contrast-enhanced harmonic endoscopic ultrasound

    DEFF Research Database (Denmark)

    Săftoiu, A; Dietrich, C F; Vilmann, P

    2012-01-01

    Second-generation intravenous blood-pool ultrasound contrast agents are increasingly used in endoscopic ultrasound (EUS) for characterization of microvascularization, differential diagnosis of benign and malignant focal lesions, and improving staging and guidance of therapeutic procedures. Although...... initially used as Doppler signal enhancers, second-generation microbubble contrast agents are now used with specific contrast harmonic imaging techniques, which benefit from the highly nonlinear behavior of the microbubbles. Contrast-specific modes based on multi-pulse technology are used to perform...... contrast-enhanced harmonic EUS based on a very low mechanical index (0.08 - 0.12). Quantification techniques based on dynamic contrast-enhanced ultrasound have been recommended for perfusion imaging and monitoring of anti-angiogenic treatment, mainly based on time-intensity curve analysis. Most...

  16. [Ultrasound guided percutaneous nephrolithotripsy].

    Science.gov (United States)

    Guliev, B G

    2014-01-01

    The study was aimed to the evaluation of the effectiveness and results of ultrasound guided percutaneous nephrolithotripsy (PNL) for the treatment of patients with large stones in renal pelvis. The results of PNL in 138 patients who underwent surgery for kidney stones from 2011 to 2013 were analyzed. Seventy patients (Group 1) underwent surgery with combined ultrasound and radiological guidance, and 68 patients (Group 2)--only with ultrasound guidance. The study included patients with large renal pelvic stones larger than 2.2 cm, requiring the formation of a single laparoscopic approach. Using the comparative analysis, the timing of surgery, the number of intra- and postoperative complications, blood loss and length of stay were evaluated. Percutaneous access was successfully performed in all patients. Postoperative complications (exacerbation of chronic pyelonephritis, gross hematuria) were observed in 14.3% of patients in Group 1 and in 14.7% of patients in Group 2. Bleeding requiring blood transfusion, and injuries of adjacent organs were not registered. Efficacy of PNL in the Group 1 was 95.7%; 3 (4.3%) patients required additional interventions. In Group 2, the effectiveness of PNL was 94.1%, 4 (5.9%) patients additionally underwent extracorporeal lithotripsy. There were no significant differences in the effectiveness of PNL, the volume of blood loss and duration of hospitalization. Ultrasound guided PNL can be performed in large pelvic stones and sufficient expansion of renal cavities, thus reducing radiation exposure of patients and medical staff.

  17. Mirizzi Syndrome with Endoscopic Ultrasound Image

    Directory of Open Access Journals (Sweden)

    K. Rayapudi

    2013-05-01

    Full Text Available We describe a 66-year-old Caucasian man with type 1 Mirizzi syndrome diagnosed on endoscopic ultrasound. He presented with acute onset of jaundice, malaise, dark urine over 3-4 days, and was found to have obstructive jaundice on lab testing. CT scan of the abdomen showed intrahepatic biliary ductal dilation, a 1.5 cm common bile duct (CBD above the pancreas, and possible stones in the CBD, but no masses. Endoscopic retrograde cholangiopancreatography (ERCP by a community gastroenterologist failed to cannulate the CBD. At the University Center, type 1 Mirizzi syndrome was noted on endoscopic ultrasound with narrowing of the CBD with extrinsic compression from cystic duct stone. During repeat ERCP, the CBD could be cannulated over the pancreatic duct wire. A mid CBD narrowing, distal CBD stones, proximal CBD and extrahepatic duct dilation were noted, and biliary sphincterotomy was performed. A small stone in the distal CBD was removed with an extraction balloon. The cystic duct stone was moved with the biliary balloon into the CBD, mechanical basket lithotripsy was performed and stone fragments were delivered out with an extraction balloon. The patient was seen 7 weeks later in the clinic. Skin and scleral icterus had cleared up and he is scheduled for an elective cholecystectomy. Mirizzi syndrome refers to biliary obstruction resulting from impacted stone in the cystic duct or neck of the gallbladder and commonly presents with obstructive jaundice. Type 1 does not have cholecystocholedochal fistulas, but they present in types 2, 3 and 4. Surgery is the mainstay of therapy. Endoscopic treatment is effective and can also be used as a temporizing measure or definitive treatment in poor surgical risk candidates.

  18. Endoscopic ultrasound features of chronic pancreatitis

    DEFF Research Database (Denmark)

    Rana, Surinder Singh; Vilmann, Peter

    2015-01-01

    As endoscopic ultrasound (EUS) is the most sensitive imaging modality for diagnosing pancreatic disorders, it can demonstrate subtle alterations in the pancreatic parenchymal and ductal structure even before traditional imaging and functional testing demonstrate any abnormality. In spite...... of this fact and abundant literature, the exact role of EUS in the diagnosis of chronic pancreatitis (CP) is still not established. The EUS features to diagnose CP have evolved over a period from a pure qualitative approach to more advanced and complicated scoring systems incorporating multiple parenchymal...... to define the exact role of these criteria. The measurement of strain ratio using quantitative EUS elastography and thus allowing quantification of pancreatic fibrosis seems to be a promising new technique....

  19. Ultrasound-assisted endoscopic partial plantar fascia release.

    Science.gov (United States)

    Ohuchi, Hiroshi; Ichikawa, Ken; Shinga, Kotaro; Hattori, Soichi; Yamada, Shin; Takahashi, Kazuhisa

    2013-01-01

    Various surgical treatment procedures for plantar fasciitis, such as open surgery, percutaneous release, and endoscopic surgery, exist. Skin trouble, nerve disturbance, infection, and persistent pain associated with prolonged recovery time are complications of open surgery. Endoscopic partial plantar fascia release offers the surgeon clear visualization of the anatomy at the surgical site. However, the primary medial portal and portal tract used for this technique have been shown to be in close proximity to the posterior tibial nerves and their branches, and there is always the risk of nerve damage by introducing the endoscope deep to the plantar fascia. By performing endoscopic partial plantar fascia release under ultrasound assistance, we could dynamically visualize the direction of the endoscope and instrument introduction, thus preventing nerve damage from inadvertent insertion deep to the fascia. Full-thickness release of the plantar fascia at the ideal position could also be confirmed under ultrasound imaging. We discuss the technique for this new procedure.

  20. Endoscopic ultrasound coil placement of gastric varices: Emerging modality for recurrent bleeding gastric varices

    Directory of Open Access Journals (Sweden)

    Yogesh Harwani

    2014-01-01

    Full Text Available Gastric varices are the probable source of bleeding in 10-36% of patients, with acute variceal bleeding and carry high mortality and rebleeding rates. Till date, cyanoacrylate glue injection is considered as the standard of care but has high complication rate. Endoscopic ultrasound (EUS guided coil placement is a new emerging technique of management of gastric varices. In this case report, we detail the EUS guided coil placement for management of gastric varices after failed glue injections.

  1. A Man with Pancreatic Head Mass Lesion on Endoscopic Ultrasound and Granuloma on Cytopathology

    Directory of Open Access Journals (Sweden)

    Neda Rad

    2016-12-01

    Full Text Available Primary pancreatic lymphoma is an unlikely malignancy accounting for less than 0.5% of pancreatic tumors. Clinical presentation is often nonspecific and may be clinically misdiagnosed as pancreatic adenocarcinoma. Here we present an Iranian case of primary pancreatic lymphoma in a 47-year-old male suffering from jaundice and 20% weight loss. Endoscopic ultrasound revealed a mixed echoic mass lesion at the head of pancreas. The patient underwent endoscopic ultrasound-guided fine needle aspiration of solid pancreatic mass and histopathologic diagnosis revealed granuloma. Computed tomography-guided core needle biopsy was performed and eventually histological examination showed granuloma that was coherent with the diagnosis of primary pancreatic lymphoma. Primary pancreatic lymphoma is a rare entity presenting with nonspecific symptoms, laboratory and radiological findings. Computed tomography results in combination with clinical and radiological studies generally provide guidance for appropriate investigation.

  2. A Man with Pancreatic Head Mass Lesion on Endoscopic Ultrasound and Granuloma on Cytopathology.

    Science.gov (United States)

    Rad, Neda; Heidarnezhad, Arash; Soheili, Setareh; Mohammad-Alizadeh, Amir Houshang; Nikmanesh, Arash

    2016-01-01

    Primary pancreatic lymphoma is an unlikely malignancy accounting for less than 0.5% of pancreatic tumors. Clinical presentation is often nonspecific and may be clinically misdiagnosed as pancreatic adenocarcinoma. Here we present an Iranian case of primary pancreatic lymphoma in a 47-year-old male suffering from jaundice and 20% weight loss. Endoscopic ultrasound revealed a mixed echoic mass lesion at the head of pancreas. The patient underwent endoscopic ultrasound-guided fine needle aspiration of solid pancreatic mass and histopathologic diagnosis revealed granuloma. Computed tomography-guided core needle biopsy was performed and eventually histological examination showed granuloma that was coherent with the diagnosis of primary pancreatic lymphoma. Primary pancreatic lymphoma is a rare entity presenting with nonspecific symptoms, laboratory and radiological findings. Computed tomography results in combination with clinical and radiological studies generally provide guidance for appropriate investigation.

  3. [Ultrasound-guided peripheral catheterization].

    Science.gov (United States)

    Salleras-Duran, Laia; Fuentes-Pumarola, Concepció

    2016-01-01

    Peripheral catheterization is a technique that can be difficult in some patients. Some studies have recently described the use of ultrasound to guide the venous catheterization. To describe the success rate, time required, complications of ultrasound-guided peripheral venous catheterization. and patients and professionals satisfaction The search was performed in databases (Medline-PubMed, Cochrane Library, CINAHL and Cuiden Plus) for studies published about ultrasound-guided peripheral venous catheterization performed on patients that provided results on the success of the technique, complications, time used, patient satisfaction and the type of professional who performed the technique. A total of 21 studies were included. Most of them get a higher success rate 80% in the catheterization ecoguide and time it is not higher than the traditional technique. The Technical complications analyzed were arterial puncture rates and lower nerve 10%. In all studies measuring and comparing patient satisfaction in the art ecoguide is greater. Various professional groups perform the technique. The use of ultrasound for peripheral pipes has a high success rate, complications are rare and the time used is similar to that of the traditional technique. The technique of inserting catheters through ultrasound may be learned by any professional group performing venipuncture. Finally, it gets underscores the high patient satisfaction with the use of this technique. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  4. Ultrasound-controlled neuronavigator-guided brain surgery.

    Science.gov (United States)

    Koivukangas, J; Louhisalmi, Y; Alakuijala, J; Oikarinen, J

    1993-07-01

    The development of a unique neurosurgical navigator is described and a preliminary series of seven cases of intracerebral lesions approached with the assistance of this neuronavigation system under ultrasound control is presented. The clinical series included five low-grade astrocytomas, one chronic intracerebral hematoma, and one porencephalic cyst. Management procedures included biopsy in all cases, drainage of the hematoma, and endoscopy and fenestration for the cyst. The features of the neuronavigation system are interactive reconstructions of preoperative computerized tomography and magnetic resonance imaging data, corresponding intraoperative ultrasound images, versatility of the interchangeable end-effector instruments, graphic presentation of instruments on the reconstructed images, and voice control of the system. The principle of a common axis in the reconstructed images served to align the navigational pointer, biopsy guide, endoscope guide, ultrasound transducer, and surgical microscope to the brain anatomy. Intraoperative ultrasound imaging helped to verify the accuracy of the neuronavigator and check the results of the procedures. The arm of the neuronavigation system served as a holder for instruments, such as the biopsy guide, endoscope guide, and ultrasound transducer, in addition to functioning as a navigational pointer. Also, the surgical microscope was aligned with the neuronavigator for inspection and biopsy of the hematoma capsule to rule out tumor etiology. Voice control freed the neurosurgeon from manual exercises during start-up and calibration of the system.

  5. The role of contrast-enhanced endoscopic ultrasound in pancreatic adenocarcinoma

    DEFF Research Database (Denmark)

    Saftoiu, Adrian; Vilmann, Peter; Bhutani, Manoop S

    2016-01-01

    contrast agents for early detection, tridimensional and fusion techniques for enhanced staging and resectability assessment but also novel applications of perfusion imaging for monitoring ablative therapy, improved local detection through EUS-guided sampling of portal vein flow or enhanced drug delivery......Contrast-enhanced endoscopic ultrasound (CE-EUS) allows characterization, differentiation, and staging of focal pancreatic masses. The method has a high sensitivity and specificity for the diagnosis of pancreatic adenocarcinoma which is visualized as hypo-enhanced as compared to the rest...... of the parenchyma while chronic pancreatitis and neuroendocrine tumors are generally either iso-enhanced or hyper-enhanced. The development of contrast-enhanced low mechanical index harmonic imaging techniques used in real time during endoscopic ultrasound (EUS) allowed perfusion imaging and the quantification...

  6. Technical aspects of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Technical Guideline - March 2017.

    Science.gov (United States)

    Polkowski, Marcin; Jenssen, Christian; Kaye, Philip; Carrara, Silvia; Deprez, Pierre; Gines, Angels; Fernández-Esparrach, Gloria; Eisendrath, Pierre; Aithal, Guruprasad P; Arcidiacono, Paolo; Barthet, Marc; Bastos, Pedro; Fornelli, Adele; Napoleon, Bertrand; Iglesias-Garcia, Julio; Seicean, Andrada; Larghi, Alberto; Hassan, Cesare; van Hooft, Jeanin E; Dumonceau, Jean-Marc

    2017-10-01

    For routine EUS-guided sampling of solid masses and lymph nodes (LNs) ESGE recommends 25G or 22G needles (high quality evidence, strong recommendation); fine needle aspiration (FNA) and fine needle biopsy (FNB) needles are equally recommended (high quality evidence, strong recommendation).When the primary aim of sampling is to obtain a core tissue specimen, ESGE suggests using 19G FNA or FNB needles or 22G FNB needles (low quality evidence, weak recommendation).ESGE recommends using 10-mL syringe suction for EUS-guided sampling of solid masses and LNs with 25G or 22G FNA needles (high quality evidence, strong recommendation) and other types of needles (low quality evidence, weak recommendation). ESGE suggests neutralizing residual negative pressure in the needle before withdrawing the needle from the target lesion (moderate quality evidence, weak recommendation).ESGE does not recommend for or against using the needle stylet for EUS-guided sampling of solid masses and LNs with FNA needles (high quality evidence, strong recommendation) and suggests using the needle stylet for EUS-guided sampling with FNB needles (low quality evidence, weak recommendation).ESGE suggests fanning the needle throughout the lesion when sampling solid masses and LNs (moderate quality evidence, weak recommendation).ESGE equally recommends EUS-guided sampling with or without on-site cytologic evaluation (moderate quality evidence, strong recommendation). When on-site cytologic evaluation is unavailable, ESGE suggests performance of three to four needle passes with an FNA needle or two to three passes with an FNB needle (low quality evidence, weak recommendation).For diagnostic sampling of pancreatic cystic lesions without a solid component, ESGE suggests emptying the cyst with a single pass of a 22G or 19G needle (low quality evidence, weak recommendation). For pancreatic cystic lesions with a solid component, ESGE suggests sampling of the solid component using the same technique as in the

  7. Ultrasound-guided percutaneous biopsy of digestive tract lesions

    International Nuclear Information System (INIS)

    Gil, S.; Martin, I.; Ballesteros, J. M.; Gomez, C.; Marco, S. F.; Fernandez, P.

    1999-01-01

    To present our experience in ultrasound-guided percutaneous biopsy of lesions located in the digestive tract. We performed ultrasound-guided percutaneous biopsy in 14 patients (10 men and 4 women) ranging in age from 7 to 71 years (mean; 519 years). The lesions were located throughout the digestive tract, from the pyriform sinus to the sigmoid colon. The biopsy was carried out with a 5 MHz convex probe equipped with a device to direct the needle. An 18G automatic needle or a 20G Chiba needle was used to obtain specimens for histological study in every case, and additional samples were collected with a 22G needle for cytological examination in 13 of the patients. The ultrasound images corresponded to pseudokidney in 9 cases and extrinsic masses in 5. The diagnosis was obtained from the histological examination in every case (100%) and from cytology in 6 (44.4%), the latter results were less specific. The only complication corresponded to a case of bilioperitoneum. Ultrasound-guided percutaneous biopsy is a suitable technique for the histological diagnosis of those lesions of the digestive tract that are visible in ultrasound images, but that for some reason can not be examined by endoscopic biopsy. (Author) 20 refs

  8. Endoscopic ultrasound in pancreatic cancer: innovative applications beyond the basics.

    Science.gov (United States)

    Yoo, Joseph; Kistler, C Andrew; Yan, Linda; Dargan, Andrew; Siddiqui, Ali A

    2016-12-01

    Endoscopic ultrasound (EUS) has become a mainstay in assisting in the diagnosis and staging of pancreatic cancer. In addition, EUS provides a modality to treat chronic pain through celiac plexus neurolysis. Currently, there is growing data and utilization of EUS in more diverse and innovative applications aimed at providing more sophisticated diagnostic, prognostic and therapeutic options for patients with pancreatic cancer. EUS delivery of chemotherapy, viral and biological vectors and fiducial markers may eventually revolutionize the way clinicians approach the care of a patient with pancreatic cancer.

  9. A novel fusion imaging system for endoscopic ultrasound

    DEFF Research Database (Denmark)

    Gruionu, Lucian Gheorghe; Saftoiu, Adrian; Gruionu, Gabriel

    2016-01-01

    BACKGROUND AND OBJECTIVE: Navigation of a flexible endoscopic ultrasound (EUS) probe inside the gastrointestinal (GI) tract is problematic due to the small window size and complex anatomy. The goal of the present study was to test the feasibility of a novel fusion imaging (FI) system which uses...... time was 24.6 ± 6.6 min, while the time to reach the clinical target was 8.7 ± 4.2 min. CONCLUSIONS: The FI system is feasible for clinical use, and can reduce the learning curve for EUS procedures and improve navigation and targeting in difficult anatomic locations....

  10. [The use of intraoperative Doppler ultrasound in endoscopic transsphenoidal surgery].

    Science.gov (United States)

    Sharipov, O I; Kutin, M A; Kalinin, P L; Fomichev, D V; Lukshin, V A; Kurnosov, A B

    2016-01-01

    Doppler ultrasound (DUS) has been widely used in neurosurgical practice to diagnose various cerebrovascular diseases. This technique is used in transsphenoidal surgery to identify the localization of intracranial arteries when making an approach or during tumor resection. To identify the cavernous segment of the internal carotid artery (ICA) and/or basilar artery during endoscopic transsphenoidal surgery, we used a combined device on the basis of a click line curette («Karl Storz») and a 16 MHz Doppler probe (Lassamed). The technique was used in 51 patients during both standard transsphenoidal surgery (23 cases) and transsphenoidal tumor resection through an extended approach (28 cases). Doppler ultrasound was used in different situations: to determine a trajectory of the endonasal transsphenoidal approach in the absence of the normal anatomical landmarks (16 cases), to define the limits of safe resection of a tumor located in the laterosellar region (7), and to implement an extended transsphenoidal endoscopic approach (28). Intraoperative Doppler ultrasound enabled identification of the cavernous segment of the internal carotid artery in 45 cases and the basilar artery in 2 cases; a blood vessel was not found in 4 cases. Injury to the cavernous segment of the internal carotid artery was observed only in 1 case. The use of the described combined device in transsphenoidal surgery turned Doppler ultrasound into an important and useful technique for visualization of the ICA within the tumor stroma as well as in the case of the changed skull base anatomy. Its use facilitates manipulations in a deep and narrow wound and enables inspection of the entire surface of the operative field in various planes, thereby surgery becomes safer due to the possibility of maximum investigation of the operative field.

  11. Imaging of common bile duct by linear endoscopic ultrasound

    Institute of Scientific and Technical Information of China (English)

    Malay; Sharma; Amit; Pathak; Abid; Shoukat; Chittapuram; Srinivasan; Rameshbabu; Akash; Ajmera; Zeeshn; Ahamad; Wani; Praveer; Rai

    2015-01-01

    Imaging of common bile duct(CBD) can be done by many techniques. Endoscopic retrograde cholangiopancreaticography is considered the gold standard for imaging of CBD. A standard technique of imaging of CBD by endoscopic ultrasound(EUS) has not been specifically described. The available descriptions mention different stations of imaging from the stomach and duodenum. The CBD lies closest to duodenum and choice of imaging may be restricted to duodenum for many operators. Generally most operators prefer multi station imaging during EUS and the choice of selecting the initial station varies from operator to operator. Detailed evaluation of CBD is frequently the main focus of imaging during EUS and in such situations multi station imaging with a high-resolution ultrasound scanner may provide useful information. Examination of the CBD is one of the primary indications for doing an EUS and it can be done from five stations:(1) the fundus of stomach;(2) body of stomach;(3) duodenal bulb;(4) descending duodenum; and(5) antrum. Following down the upper 1/3rd of CBD can do imaging of entire CBD from the liver window and following up the lower 1/3rd of CBD can do imaging of entire CBD from the pancreatic window. This article aims at simplifying the techniques of imaging of CBD by linear EUS.

  12. Comparison of ultrasound evaluation of patients of obstructive jaundice with endoscopic retrograde cholangio-pancreatography findings

    International Nuclear Information System (INIS)

    Farrukh, S.Z.U.I.; Siddiqui, A.R.; Haqqi, S.A.; Muhammad, A.J.

    2017-01-01

    Ultrasonography has proven to be quite effective in differentiating hepatocellular from obstructive cause of jaundice in various studies. This study was conducted with the aim to determine the efficacy of ultrasonography and Endoscopic Retrograde Cholangio-Pancreatography (ERCP) in the diagnosis of obstructive reason of jaundice. Methods: In this descriptive case series, 200 patients with >15 years age of either gender with cholestatic liver enzymes were included, i.e., those patients who had an ultrasound prior to ERCP at the department of gastroenterology of Patel Hospital, Karachi. Patients known to have liver disease with cholestatic jaundice had imaging other than ultrasound were excluded. The results of ultrasonography and ERCPs were compared in particularly looking for the cause of obstruction. Results: Out of total 200 patients, mean age was 41.22+-12.46 years with 107 (53.5 percent) females. Ability of ultrasound in correctly diagnosing obstructive reason for stone CBD was found to be 72.5 percent, dilated CBD without reason 41.7 percent, proximal obstruction, 63.15 percent, distal CBD obstruction 60 percent, and sludge 66.7 percent. Overall ability of ultrasound in correctly diagnosing the cause of obstruction was 64.17 percent. Conclusion: Ultrasound is recommended as the initial examination, which provides a guide to choose patients for either a more advanced non-invasive imaging like MRCP or to an invasive procedure like ERCP. (author)

  13. Ultrasound guided synovial biopsy of the wrist

    NARCIS (Netherlands)

    van Vugt, R. M.; van Dalen, A.; Bijlsma, J. W.

    1997-01-01

    Seven patients (4 female and 3 male, mean age 46) with arthritis of the wrist (n = 7) without known etiology were evaluated. High-definition ultrasound equipment was used for localization of synovial hypertrophy, suitable for ultrasound guided biopsy without risk. A 18-gauge diameter Tru-cut biopsy

  14. Transbiliary intravascular ultrasound-guided diagnostic biopsy of an inaccessible pancreatic head mass

    Directory of Open Access Journals (Sweden)

    Jeffrey Forris Beecham Chick, MD, MPH, DABR

    2017-06-01

    Full Text Available Percutaneous image-guided biopsies of pancreatic malignancies may prove challenging and nondiagnostic due to a variety of anatomic considerations. For patients with complex post-surgical anatomy, such as a Roux-en-Y gastric bypass, diagnosis via endoscopic ultrasound with fine-needle aspiration may not be possible because of an inability to reach the proximal duodenum. This report describes the first diagnostic case of transbiliary intravascular ultrasound-guided biopsy of a pancreatic head mass in a patient with prior Roux-en-Y gastric bypass for which a diagnosis could not be achieved via percutaneous and endoscopic approaches. Transbiliary intravascular ultrasound-guided biopsy resulted in a diagnosis of pancreatic adenocarcinoma, allowing the initiation of chemotherapy.

  15. Cancer of the esophagus--endoscopic ultrasound: selection for cure.

    Science.gov (United States)

    Caletti, G; Bocus, P; Fusaroli, P; Togliani, T; Marhefka, G; Roda, E

    1998-01-01

    Several treatment options are available to treat esophageal cancer. Ideally, treatment should be individualized, based on the projected treatment outcome for that individual. Accurate staging of the extent of the disease at the time of diagnosis offers the most rational attempt at stratifying patients into categories that can be used to affect treatment choices. Endoscopic ultrasonography (EUS) is the most accurate nonoperative technique for determining the depth of tumour infiltration and thus is accurate in predicting which patients will be able to undergo complete resection. EUS is also being used for tumour staging in order to guide treatment decisions in patients with esophageal cancer.

  16. Endoscopic ultrasound in gastroenterology: from diagnosis to therapeutic implications.

    Science.gov (United States)

    Mekky, Mohamed A; Abbas, Wael A

    2014-06-28

    Since its advent in 1980, the scope of endoscopic ultrasound (EUS) has grown to include a wide range of indications, and it is now being incorporated as an integral part of everyday practice in the field of gastroenterology. Its use is extending from an adjuvant imaging aid to utilization as a therapeutic tool for various gastrointestinal disorders. EUS was first used to visualize remote organs, such as the pancreas and abdominal lymph nodes. When fine needle aspiration was introduced, the indications for EUS expanded to include tissue sampling for diagnostic purposes. At the same time, the needle can be used to convey a potential therapy to the internal organs, allowing access to remote sites. In this review, we aim to highlight the expanding spectrum of EUS indications and uses in the field of gastroenterology.

  17. Role of endoscopic ultrasound in diagnosis and management of hepatocellular carcinoma

    Directory of Open Access Journals (Sweden)

    Koduru P

    2015-10-01

    Full Text Available Pramoda Koduru,1 Rei Suzuki,2 Sundeep Lakhtakia,3 Mohan Ramchandani,3 Dadang Makmun,4 Manoop S Bhutani,1 1Department of Gastroenterology, Hepatology and Nutrition, University of Texas MD Anderson Cancer Center, Houston, TX, USA; 2Department of Gastroenterology and Rheumatology, Fukushima University School of Medicine, Fukushima, Japan; 3Asian Institute of Gastroenterology, Hyderabad, India; 4University of Indonesia/Cipto Mangunkusumo Hospital, Jakarta, Indonesia Abstract: Hepatocellular carcinoma (HCC is an aggressive tumor and a leading cause of cancer-related deaths globally. The mortality rate remains high despite many advances in treatment. HCC is frequently diagnosed late in its course due to lack of classical symptoms at earlier stages. Endoscopic ultrasound (EUS has emerged as an important diagnostic tool for the diagnostic evaluation, staging, and treatment of gastrointestinal tract disorders. EUS-guided fine needle aspiration has been a valuable addition to EUS by being able to obtain tissue under direct visualization. Here, we review the potential role of EUS in the diagnosis and management of HCC. EUS seems to be a safe and reliable alternative method for obtaining tissue for diagnosis of liver cancer, especially for lesions that are inaccessible by traditional methods. EUS could play an important role in the diagnosis and management of HCC. Keywords: endoscopic ultrasound, fine needle aspiration, hepatocellular carcinoma, hepatoma

  18. Conventional Versus Rosemont Endoscopic Ultrasound Criteria for Chronic Pancreatitis: Comparing Interobserver Reliability and Intertest Agreement

    Directory of Open Access Journals (Sweden)

    Bruce Kalmin

    2011-01-01

    Full Text Available BACKGROUND: The Rosemont criteria (RC were recently proposed by expert consensus to standardize endoscopic ultrasound (EUS features and thresholds for diagnosing chronic pancreatitis (CP; however, they are cumbersome and are not validated.

  19. Endoscope-guided pneumatic dilation for treatment of esophageal achalasia

    Science.gov (United States)

    Chuah, Seng-Kee; Wu, Keng-Liang; Hu, Tsung-Hui; Tai, Wei-Chen; Changchien, Chi-Sin

    2010-01-01

    Pneumatic dilation (PD) is considered to be the first line nonsurgical therapy for achalasia. The principle of the procedure is to weaken the lower esophageal sphincter by tearing its muscle fibers by generating radial force. The endoscope-guided procedure is done without fluoroscopic control. Clinicians usually use a low-compliance balloon such as Rigiflex dilator to perform endoscope-guided PD for the treatment of esophageal achalasia. It has the advantage of determining mucosal injury during the dilation process, so that a repeat endoscopy is not needed to assess the mucosal tearing. Previous studies have shown that endoscope-guided PD is an efficient and safe nonsurgical therapy with results that compare well with other treatment modalities. Although the results may be promising, long-term follow-up is required in the near future. PMID:20101764

  20. A Haptic Guided Robotic System for Endoscope Positioning and Holding.

    Science.gov (United States)

    Cabuk, Burak; Ceylan, Savas; Anik, Ihsan; Tugasaygi, Mehtap; Kizir, Selcuk

    2015-01-01

    To determine the feasibility, advantages, and disadvantages of using a robot for holding and maneuvering the endoscope in transnasal transsphenoidal surgery. The system used in this study was a Stewart Platform based robotic system that was developed by Kocaeli University Department of Mechatronics Engineering for positioning and holding of endoscope. After the first use on an artificial head model, the system was used on six fresh postmortem bodies that were provided by the Morgue Specialization Department of the Forensic Medicine Institute (Istanbul, Turkey). The setup required for robotic system was easy, the time for registration procedure and setup of the robot takes 15 minutes. The resistance was felt on haptic arm in case of contact or friction with adjacent tissues. The adaptation process was shorter with the mouse to manipulate the endoscope. The endoscopic transsphenoidal approach was achieved with the robotic system. The endoscope was guided to the sphenoid ostium with the help of the robotic arm. This robotic system can be used in endoscopic transsphenoidal surgery as an endoscope positioner and holder. The robot is able to change the position easily with the help of an assistant and prevents tremor, and provides a better field of vision for work.

  1. Role of endoscopic ultrasound in pediatric gastrointestinal diseases

    Directory of Open Access Journals (Sweden)

    Rajiv Ranjan Singh

    2016-01-01

    Full Text Available Endoscopic ultrasound (EUS is a well-established diagnostic and therapeutic modality for adults. It is extremely helpful for a broad range of diagnostic indications including upper gastrointestinal (GI malignancies, submucosal lesions, pancreatic lesions (masses, cystic lesions, chronic pancreatitis, etiological workup of recurrent acute pancreatitis, common bile duct evaluation (calculi versus tumor, gallbladder lesions/microliths, and rectal malignancy; well-established therapeutic roles include fine-needle aspiration of lesions/lymph nodes, pancreatic fluid collection drainage, pancreatic duct drainage, biliary drainage, gallbladder drainage, pelvic abscess drainage, celiac plexus block, or neurolysis. Some recent studies have reported the use of EUS in the pediatric population. EUS is safe and easy to perform in the pediatric population also. However, there is paucity of data on use of EUS in pediatric population. In contrast with its regular therapeutic use in adults, EUS is not commonly performed in children for therapeutic reasons and most of the data are available on diagnostic use only. All of studies have shown that EUS is safe and a useful modality with a positive impact on management in majority of study population. EUS is very useful in pediatric population for the evaluation of upper GI tract submucosal lesions or rectal masses, pancreaticobiliary disorders, characterization of esophageal strictures, and for evaluation of enteric duplication cysts. The advent of miniprobe that can be passed through conventional endoscopes has increased the applicability of EUS in infants and children. Although there are limited data regarding use of EUS in pediatric population, it appears to be a very promising diagnostic and therapeutic tool.

  2. Endoscopic ultrasound elastography for evaluation of lymph nodes and pancreatic masses: a multicenter study

    DEFF Research Database (Denmark)

    Giovannini, Marc; Thomas, Botelberge; Erwan, Bories

    2009-01-01

    AIM: To evaluate the ability of endoscopic ultrasound (EUS) elastography to distinguish benign from malignant pancreatic masses and lymph nodes. METHODS: A multicenter study was conducted and included 222 patients who underwent EUS examination with assessment of a pancreatic mass (n = 121) or lymph...... node (n = 101). The classification as benign or malignant, based on the real time elastography pattern, was compared with the classification based on the B-mode EUS images and with the final diagnosis obtained by EUS-guided fine needle aspiration (EUS-FNA) and/or by surgical pathology. An interobserver...... study was performed. RESULTS: The sensitivity and specificity of EUS elastography to differentiate benign from malignant pancreatic lesions are 92.3% and 80.0%, respectively, compared to 92.3% and 68.9%, respectively, for the conventional B-mode images. The sensitivity and specificity of EUS...

  3. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  4. Ultrasound- and MRI-Guided Prostate Biopsy

    Science.gov (United States)

    ... assistance of a nurse and an MR imaging technologist. As with the ultrasound procedure, you may receive antibiotics, sedatives and pain medication before the biopsy. The MRI-guided procedure may use contrast ... A nurse or technologist will insert an intravenous (IV) catheter into a ...

  5. Ultrasound-guided forceps for pleural biopsy

    Directory of Open Access Journals (Sweden)

    Gamal Agmy

    2014-04-01

    Clinical implications: Ultrasound-guided forceps for pleural biopsy can overcome many of the limitations of the conventional needle biopsy procedures, provides multiple biopsy specimens of the parietal pleura that are inaccessible to the biopsy needle, and can be carried out easily and safely even in sick and obese patients. The diagnostic yield is nearly similar to thoracoscopy.

  6. Ultrasound guided local steroid injection versus extracorporeal ...

    African Journals Online (AJOL)

    Nayera Saber

    2011-12-17

    Dec 17, 2011 ... Results: There was a statistically significant reduction in plantar fascia .... Several previous studies evaluate the effects of either local ... The choice of ultrasound guided technique of steroid injection was related to the accuracy of application and supe- ..... chronic proximal plantar fasciitis: a meta analysis.

  7. Endoscopic ultrasound in the diagnosis and staging of pancreatic cancer

    Directory of Open Access Journals (Sweden)

    J. Iglesias García

    Full Text Available Pancreatic cancer is the 5th leading cause of cancer-related death in Western countries. The 5-year survival rate is approximately 4%, without significant changes over the last 50 years. This poor survival rate and bad prognosis are associated with the diagnosis of advanced-stage disease, which precludes the only potential curative treatment - surgical resection. In this setting, the main objective in the management of pancreatic cancer is to perform an early diagnosis and a correct staging of the disease. Endoscopic ultrasonography (EUS appears to be an essential tool for the diagnosis and staging of pancreatic cancer. EUS diagnostic accuracy for detecting pancreatic tumors ranges from 85 to 100%, clearly superior to other imaging techniques. EUS accuracy for the local staging of pancreatic cancer ranges from 70 to 90%, superior or equivalent to other imaging modalities. EUS-guided fine-needle aspiration allows a cyto-histological diagnosis in nearly 90% of cases, with a very low complication rate. At present, the formal indications for EUS-guided fine-needle aspiration are the necessity of palliative treatment or whenever the possibility of neoadjuvant treatment is present. It could be also indicated to differentiate pancreatic adenocarcinoma from other pancreatic conditions, like lymphoma, metastasis, autoimmune pancreatitis or chronic pancreatitis. We can conclude that EUS is an essential tool in the management of patients with pancreatic tumors.

  8. Endoscopic ultrasound in the diagnosis and staging of pancreatic cancer

    Directory of Open Access Journals (Sweden)

    J. Iglesias García

    2009-09-01

    Full Text Available Pancreatic cancer is the 5th leading cause of cancer-related death in Western countries. The 5-year survival rate is approximately 4%, without significant changes over the last 50 years. This poor survival rate and bad prognosis are associated with the diagnosis of advanced-stage disease, which precludes the only potential curative treatment - surgical resection. In this setting, the main objective in the management of pancreatic cancer is to perform an early diagnosis and a correct staging of the disease. Endoscopic ultrasonography (EUS appears to be an essential tool for the diagnosis and staging of pancreatic cancer. EUS diagnostic accuracy for detecting pancreatic tumors ranges from 85 to 100%, clearly superior to other imaging techniques. EUS accuracy for the local staging of pancreatic cancer ranges from 70 to 90%, superior or equivalent to other imaging modalities. EUS-guided fine-needle aspiration allows a cyto-histological diagnosis in nearly 90% of cases, with a very low complication rate. At present, the formal indications for EUS-guided fine-needle aspiration are the necessity of palliative treatment or whenever the possibility of neoadjuvant treatment is present. It could be also indicated to differentiate pancreatic adenocarcinoma from other pancreatic conditions, like lymphoma, metastasis, autoimmune pancreatitis or chronic pancreatitis. We can conclude that EUS is an essential tool in the management of patients with pancreatic tumors.

  9. Outcomes of ultrasound guided renal mass biopsies.

    Science.gov (United States)

    Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary

    2018-06-01

    The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.

  10. Endoscopic ultrasonography-guided rendezvous technique.

    Science.gov (United States)

    Tsuchiya, Takayoshi; Itoi, Takao; Sofuni, Atsushi; Tonozuka, Ryosuke; Mukai, Shuntaro

    2016-04-01

    Endoscopic retrograde cholangiopancreatography (ERCP) requires deep biliary cannulation. When deep biliary cannulation is failed, the endoscopic ultrasonography rendezvous technique (EUS-RV) is a useful salvage method. From the previous 15 articles that included 382 EUS-RV cases, the overall success rate of EUS-RV is 81 % with a complication rate of 10 %. In EUS-RV, the bile duct is punctured under EUS guidance and a guidewire is advanced into the duodenum via the papilla. The EUS scope is then switched to a duodenoscope and inserted into the bile duct over the guidewire exiting the papilla, or the guidewire is grasped with forceps and passed through the working channel; the catheter can then be inserted through the papilla over the wire. There are three puncture routes for EUS-RV: transgastric puncture of the intrahepatic bile duct (IHBD), transduodenal puncture of the extrahepatic bile duct (EHBD) via the proximal duodenum (D1), and transduodenal puncture of the EHBD via the second portion of the duodenum (D2). The puncture route for each patient should be selected based on the patient condition. GW selection for EUS-RV is critical, a hydrophilic GW is useful for this procedure. Although EUS-RV is now performed relatively routinely in a few high-volume centers, procedure standardization and the development of exclusive devices for EUS-RV are still underway. The development of exclusive devices for EUS-RV and prospective comparative studies with other salvage methods are needed to truly evaluate the procedure's usefulness and safety.

  11. Ultrasound-guided sacroiliac joint injection technique.

    LENUS (Irish Health Repository)

    Harmon, Dominic

    2008-07-01

    We describe a case report and technique for using a portable ultrasound scanner and a curvilinear transducer (4-5MHz) (SonoSite Micromaxx SonoSite, Inc. 21919 30th Drive SE Bothwell W. A.) to guide sacroiliac joint (SIJ) injection. A 42-year-old male presented with chronic lower back pain centered on his left SIJ. His pain averaged 7 out of 10 (numerical rating scale). For the ultrasound-guided SIJ injection the patient was placed in the prone position. The ultrasound transducer was oriented in a transverse orientation at the level of the sacral hiatus. Here the sacral cornuae were identified. Moving the transducer laterally from here, the lateral edge of the sacrum was identified. This bony edge was followed in a cephalad direction with the transducer maintained in a transverse orientation. A second bony contour, the ileum, was identified. The cleft between both bony contours represented the sacroiliac joint. This was found at 4.5 cm depth. Real-time imaging was used to direct a 22G spinal needle into the SIJ, where solution was injected under direct vision. The patient\\'s pain intensity decreased to a 2 out of 10 (numerical rating scale). Function improved and the patient was able to return to work. These improvements were maintained at 16 weeks. Ultrasound guidance does not expose patients and personnel to radiation and is readily accessible. Ultrasound-guided SIJ injections may have particular applications in the management of chronic lower back pain in certain clinical scenarios (e.g. pregnancy). Future studies to demonstrate efficacy and reproducibility are needed.

  12. Tuberculosis and the pancreas: a diagnostic challenge solved by endoscopic ultrasound. A case series.

    Science.gov (United States)

    Chatterjee, Suvadip; Schmid, Matthias L; Anderson, Kirsty; Oppong, Kofi W

    2012-03-01

    Pancreatic tuberculosis is a rare disease. It can be easily confused with malignancy or pancreatitis on imaging. This could result in unnecessary surgery. As this is a treatable disease it is imperative to diagnose this condition pre-operatively. We report three cases of pancreatic tuberculosis that were diagnosed by endoscopic ultrasound. In conclusion, endoscopic ultrasound is the diagnostic modality of choice for pancreatic tuberculosis facilitating high resolution imaging, as well as sampling of tissue for staining, cytology, culture and polymerase chain reaction assay.

  13. Ultrasound-guided removal of Implanon devices.

    LENUS (Irish Health Repository)

    Persaud, T

    2008-11-01

    Our study has shown that ultrasound-guided localisation and removal of Implanon rods is safe, practical and highly successful. Over a 4-year period, 119 patients had successful, uncomplicated removal of their subdermal devices.The technique is particularly useful for removal of the device when it is not palpable or when an attempt at removal of a palpable device has not been successful.

  14. CT and Ultrasound Guided Stereotactic High Intensity Focused Ultrasound (HIFU)

    Science.gov (United States)

    Wood, Bradford J.; Yanof, J.; Frenkel, V.; Viswanathan, A.; Dromi, S.; Oh, K.; Kruecker, J.; Bauer, C.; Seip, R.; Kam, A.; Li, K. C. P.

    2006-05-01

    animals and humans for HIFU-induced ablation and drug delivery. Integrated CT-guided focused ultrasound holds promise for tissue ablation, enhancing local drug delivery, and CT thermometry for monitoring ablation in near real-time.

  15. Intraoperative endoscopic ultrasound guidance for laparoscopic excision of invisible symptomatic deep intramural myomas.

    Science.gov (United States)

    Urman, Bulent; Boza, Aysen; Ata, Baris; Aksu, Sertan; Arslan, Tonguc; Taskiran, Cagatay

    2018-01-01

    The aim of this study was to evaluate the feasibility of intraoperative endoscopic ultrasound guidance for excision of symptomatic deep intramural myomas that are not otherwise visible at laparoscopy. Seventeen patients with symptomatic deep intramural myomas who underwent laparoscopic myomectomy with intraoperative endoscopic ultrasound guidance were followed up and reported. All myomas were removed successfully. The endometrium was breached in one patient. All patients were relieved of their symptoms and three patients presenting with infertility conceived. There were no short- or long-term complications associated with the procedure. One patient who had multiple myomas necessitated intravenous iron treatment prior to discharge. Laparoscopic removal of small symptomatic deep intramural myomas is facilitated by the use of intraoperative endoscopic ultrasound that enables exact localisation and correct placement of the serosal incision. Impact statement What is already known on this subject: When the myoma is symptomatic, compressing the endometrium, does not show serosal protrusion and is not amenable to hysteroscopic resection, laparoscopic surgery may become challenging. What do the results of this study add: The use of intraoperative endoscopic ultrasound under these circumstances may facilitate the procedure by accurate identification of the myoma and correct placement of the serosal incision. What are the implications of these findings for clinical practice and/or further research: Intraoperative ultrasound should be more oftenly used to accurately locate deep intramural myomas to the end of making laparoscopy feasible and possibly decreasing recurrence by facilitating removal of otherwise unidentifiable disease.

  16. Does endoscopic ultrasound improve detection of locally recurrent anal squamous-cell cancer?

    Science.gov (United States)

    Peterson, Carrie Y; Weiser, Martin R; Paty, Philip B; Guillem, Jose G; Nash, Garrett M; Garcia-Aguilar, Julio; Patil, Sujata; Temple, Larissa K

    2015-02-01

    Evaluating patients for recurrent anal cancer after primary treatment can be difficult owing to distorted anatomy and scarring. Many institutions incorporate endoscopic ultrasound to improve detection, but the effectiveness is unknown. The aim of this study is to compare the effectiveness of digital rectal examination and endoscopic ultrasound in detecting locally recurrent disease during routine follow-up of patients with anal cancer. This study is a retrospective, single-institution review. This study was conducted at an oncologic tertiary referral center. Included were 175 patients with nonmetastatic anal squamous-cell cancer, without persistent disease after primary chemoradiotherapy, who had at least 1 posttreatment ultrasound and examination by a colorectal surgeon. The primary outcomes measured were the first modality to detect local recurrence, concordance, crude cancer detection rate, sensitivity, specificity, and predictive value. Eight hundred fifty-five endoscopic ultrasounds and 873 digital rectal examinations were performed during 35 months median follow-up. Overall, ultrasound detected 7 (0.8%) mesorectal and 32 (3.7%) anal canal abnormalities; digital examination detected 69 (7.9%) anal canal abnormalities. Locally recurrent disease was found on biopsy in 8 patients, all detected first or only with digital examination. Four patients did not have an ultrasound at the time of diagnosis of recurrence. The concordance of ultrasound and digital examination in detecting recurrent disease was fair at 0.37 (SE, 0.08; 95% CI, 0.21-0.54), and there was no difference in crude cancer detection rate, sensitivity, specificity, and negative or positive predictive values. The heterogeneity of follow-up timing and examinations is not standardized in this study but is reflective of general practice. Endoscopic ultrasound did not provide any advantage over digital rectal examination in identifying locally recurrent anal cancer, and should not be recommended for

  17. Existing Evidence on Ultrasound-Guided Injections in Sports Medicine.

    Science.gov (United States)

    Daniels, Eldra W; Cole, David; Jacobs, Bret; Phillips, Shawn F

    2018-02-01

    Office-based ultrasonography has become increasingly available in many settings, and its use to guide joint and soft tissue injections has increased. Numerous studies have been conducted to evaluate the use of ultrasound-guided injections over traditional landmark-guided injections, with a rapid growth in the literature over the past few years. A comprehensive review of the literature was conducted to demonstrate increased accuracy of ultrasound-guided injections regardless of anatomic location. In the upper extremity, ultrasound-guided injections have been shown to provide superior benefit to landmark-guided injections at the glenohumeral joint, the subacromial space, the biceps tendon sheath, and the joints of the hand and wrist. Ultrasound-guided injections of the acromioclavicular and the elbow joints have not been shown to be more efficacious. In the lower extremity, ultrasound-guided injections at the knee, ankle, and foot have superior efficacy to landmark-guided injections. Conclusive evidence is not available regarding improved efficacy of ultrasound-guided injections of the hip, although landmark-guided injection is performed less commonly at the hip joint. Ultrasound-guided injections are overall more accurate than landmark-guided injections. While current studies indicate that ultrasound guidance improves efficacy and cost-effectiveness of many injections, these studies are limited and more research is needed.

  18. Minimally Invasive Ultrasound-Guided Carpal Tunnel Release: Preliminary Clinical Results.

    Science.gov (United States)

    Henning, P Troy; Yang, Lynda; Awan, Tariq; Lueders, Daniel; Pourcho, Adam M

    2018-04-02

    Ultrasound-guided carpal tunnel release was performed on 14 patients (18 wrists) using dynamic expansion of the transverse safe zone. Our patient population included able-bodied patients and those with impairments. The first 8 cases (12 wrists) underwent the procedure in an operating room, the remainder in an outpatient setting. No complications occurred, and all patients were able to immediately resume use of their hands without therapy. Improvements in the Quick Form of the Disabilities of the Arm, Shoulder, and Hand Index and Boston Carpal Tunnel Questionnaire at 3 months were comparable to results reported with mini-open and endoscopic release. Our results show that ultrasound-guided carpal tunnel release can be safely and effectively performed in an outpatient setting. © 2018 by the American Institute of Ultrasound in Medicine.

  19. Ultrasound guided pleural biopsy in undiagnosed exudative pleural effusion patients

    Directory of Open Access Journals (Sweden)

    Adel S. Ahmed

    2016-04-01

    In conclusion: Thoracic ultrasound (TUS guided pleural biopsy had a diagnostic yield which was slightly lower but comparable to both CT guided pleural biopsy and medical thoracoscopic pleural biopsy (MT.

  20. Ultrasound guided electrochemotherapy for the treatment of a clear ...

    African Journals Online (AJOL)

    Ultrasound guided biopsy yielded a diagnosis of clear cell thymoma upon histopathology. After complete staging procedures, the owner elected to treat the cat with electrochemotherapy (ECT) using systemic bleomycin. Two sessions of ultrasound guided ECT were performed at two week intervals with trains of biphasic ...

  1. Contrast-enhanced harmonic endoscopic ultrasound in solid lesions of the pancreas: results of a pilot study.

    Science.gov (United States)

    Napoleon, B; Alvarez-Sanchez, M V; Gincoul, R; Pujol, B; Lefort, C; Lepilliez, V; Labadie, M; Souquet, J C; Queneau, P E; Scoazec, J Y; Chayvialle, J A; Ponchon, T

    2010-07-01

    Distinguishing pancreatic adenocarcinoma from other pancreatic masses remains challenging with current imaging techniques. This prospective study aimed to evaluate the accuracy of a new procedure, imaging the microcirculation pattern of the pancreas by contrast-enhanced harmonic endoscopic ultrasound (CEH-EUS) with a new Olympus prototype echo endoscope. 35 patients presenting with solid pancreatic lesions were prospectively enrolled. All patients had conventional B mode and power Doppler EUS. After an intravenous bolus injection of 2.4 ml of a second-generation ultrasound contrast agent (SonoVue) CEH-EUS was then performed with a new Olympus prototype echo endoscope (xGF-UCT 180). The microvascular pattern was compared with the final diagnosis based on the pathological examination of specimens from surgery or EUS-guided fine-needle aspiration (EUS-FNA) or on follow-up for at least 12 months. The final diagnoses were: 18 adenocarcinomas, 9 neuroendocrine tumors, 7 chronic pancreatitis, and 1 stromal tumor. Power Doppler failed to display microcirculation, whereas harmonic imaging demonstrated it in all cases. Out of 18 lesions with a hypointense signal on CEH-EUS, 16 were adenocarcinomas. The sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), and accuracy of hypointensity for diagnosing pancreatic adenocarcinoma were 89 %, 88 %, 88 %, 89 %, and 88.5 %, compared with corresponding values of 72 %, 100 %, 77 %, 100 %, and 86 % for EUS-FNA. Of five adenocarcinomas with false-negative results at EUS-FNA, four had a hypointense echo signal at CEH-EUS. CEH-EUS with the new Olympus prototype device successfully visualizes the microvascular pattern in pancreatic solid lesions, and may be useful for distinguishing adenocarcinomas from other pancreatic masses.

  2. Percutaneous antegrade pyelgraphy guided by ultrasound

    International Nuclear Information System (INIS)

    Kim, Jin Gyoo; Chung, Chun Phil; Lee, Suk Hong; Sol, Chang Hyo; Kim, Byung Soo

    1985-01-01

    The authors performed percutaneous antegrade pyelography guided by ultrasound on 33 patients, from June 1982 to October 1984, at the Department of Radiology, Busan National University Hospital. The results obtained were as follows: 1. Of the 31 cases, 17 cases (51.5%) were female and 16 cases (48.5%) were male, and age distribution was nearly even, but most prevalent age group was third decade. 2. Comparing intravenous pyelographic findings with ultrasonographic findings, pyelographically nonvisualized kidney 15 cases (45.5%) were hydronephrosis 12 cases, multiple cysts 2 cases, and intrarenal cystic mass 1 case, ultrasonographically. Pyelographically hydronephrosis 9 cases (27.3%) were all hydronephrosis, ultrasonographically. Intrarenal mass 5 cases (15.2%) were all intrarenal cystic mass, NVK with air kidney 1 case (3.0%) was air in perirenal space, partial NVK 1 case (3.0%) was perirenal fluid, suprarenal mass 1 case (3.0%) was suprarenal intrarenal and huge perirenal cystic masses, ultrasonographically. 3. On technical reliability of antegrade pyelography under ultrasound guide, 31 cases (93.9%) could be done fluid aspiration and visualization, and 2 cases (6.1%) could be only done fluid aspiration but failed visualization. 31 successful cases were visualization of collecting systems 23 cases, visualization of cyst 6 case, and visualization of perirenal space 2 cases. 2 partical successful cases were perirenal injection 1 case and parenchymal injection 1 case. 4. On fluid aspiration, 22 cases (66.7%) were clear, but 11 cases (33.3%) were not clear, which were pus 7 cases, turbid urine 2 cases, bloody urine 1 case, and bloody pus and air 1 case. 5. Comparing ultrasonographic findings with antegrade pyelographic findings, ultrasonographiclly hydronephrosis 21 cases revealed obstruction in 16 cases, antegrade pyelographicaaly, which were consisted of ureteral stricture 14 case, ureteral stone 1 case, and ureteral mass 1 case, non-obstruction in 4 cases, which

  3. Adenopathies in lung cancer: a comparison of pathology, Computed Tomography and endoscopic ultrasound findings

    International Nuclear Information System (INIS)

    Potepan, P.; Meroni, E.; Spinelli, P.

    1999-01-01

    A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread [it

  4. Endoscopic tissue diagnosis of cholangiocarcinoma.

    LENUS (Irish Health Repository)

    Harewood, Gavin C

    2008-09-01

    The extremely poor outcome in patients with cholangiocarcinoma, in large part, reflects the late presentation of these tumors and the challenging nature of establishing a tissue diagnosis. Establishing a diagnosis of cholangiocarcinoma requires obtaining evidence of malignancy from sampling of the epithelium of the biliary tract, which has proven to be challenging. Although endoscopic ultrasound-guided fine needle aspiration performs slightly better than endoscopic retrograde cholangiopancreatography in diagnosing cholangiocarcinoma, both endoscopic approaches demonstrate disappointing performance characteristics.

  5. Ultrasound-guided botulinum toxin injections

    Directory of Open Access Journals (Sweden)

    S. E. Khatkova

    2016-01-01

    Full Text Available One of the key conditions for achieving the desirable result during botulinum toxin therapy for muscular dystonia, spasticity, and other diseases accompanied by spasm, pain, and autonomic dysfunction (dystonias, spasticity, etc. is the proper administration of the agent into the muscles directly involved in the pathological process. The exact entry of botulinum toxin into the target muscles is essential for successful and safe treatment because its injection into a normal muscle may cause side effects. The most common errors are the incorrect depth and incorrect direction of a needle on insertion. Therefore, the exact injection of the agent particularly into the shallow and deep muscles is a difficult task even for an experienced specialist and requires the use of controlling methods.The European Consensus on Botulinum Toxin Therapy points out that various injection techniques are needed for the better identification of necessary muscles. However, there are currently no reports on the clear advantage of any technique. In our country, injections using palpation and anatomical landmarks have been widely used in routine practice so far; electromyographic monitoring and electrostimulation have been less frequently applied. In recent years, the new method ultrasound-guided injection has continued to grow more popular. This effective, accessible, and easy-to-use method makes it possible to manage a real-time injection process and to ensure the exact entry of the agent into the muscle. This paper is dedicated to a comparative analysis of different injection methods and to a description of the ultrasound-guided technique and its advantages over others. 

  6. Endoscopic hyperspectral imaging: light guide optimization for spectral light source

    Science.gov (United States)

    Browning, Craig M.; Mayes, Samuel; Rich, Thomas C.; Leavesley, Silas J.

    2018-02-01

    Hyperspectral imaging (HSI) is a technology used in remote sensing, food processing and documentation recovery. Recently, this approach has been applied in the medical field to spectrally interrogate regions of interest within respective substrates. In spectral imaging, a two (spatial) dimensional image is collected, at many different (spectral) wavelengths, to sample spectral signatures from different regions and/or components within a sample. Here, we report on the use of hyperspectral imaging for endoscopic applications. Colorectal cancer is the 3rd leading cancer for incidences and deaths in the US. One factor of severity is the miss rate of precancerous/flat lesions ( 65% accuracy). Integrating HSI into colonoscopy procedures could minimize misdiagnosis and unnecessary resections. We have previously reported a working prototype light source with 16 high-powered light emitting diodes (LEDs) capable of high speed cycling and imaging. In recent testing, we have found our current prototype is limited by transmission loss ( 99%) through the multi-furcated solid light guide (lightpipe) and the desired framerate (20-30 fps) could not be achieved. Here, we report on a series of experimental and modeling studies to better optimize the lightpipe and the spectral endoscopy system as a whole. The lightpipe was experimentally evaluated using an integrating sphere and spectrometer (Ocean Optics). Modeling the lightpipe was performed using Monte Carlo optical ray tracing in TracePro (Lambda Research Corp.). Results of these optimization studies will aid in manufacturing a revised prototype with the newly designed light guide and increased sensitivity. Once the desired optical output (5-10 mW) is achieved then the HIS endoscope system will be able to be implemented without adding onto the procedure time.

  7. Endoscopic ultrasound rendezvous for bile duct access using a transduodenal approach: cumulative experience at a single center. A case series.

    Science.gov (United States)

    Kim, Y S; Gupta, K; Mallery, S; Li, R; Kinney, T; Freeman, M L

    2010-06-01

    Endoscopic ultrasound (EUS)-assisted biliary access is utilized when conventional endoscopic retrograde cholangiopancreatography (ERCP) fails. We report a 10-year experience utilizing a transduodenal EUS rendezvous via a transpapillary route without dilation of the transduodenal tract, followed by immediate ERCP access. Patients included all EUS-guided rendezvous procedures for biliary access that were performed following ERCP failure. EUS-assisted bile duct puncture was performed via a transduodenal approach and a guide wire was advanced through the papilla without any dilation or bougienage of the tract; ERCP was performed immediately afterwards. EUS-assisted biliary rendezvous was attempted in 15 patients (mean age 66 +/- 18.2 years; malignant = 10, benign = 5). Mean diameter of measured bile ducts was 14.3 +/- 5.17 mm (range 4-23 mm). The reasons for initial ERCP failure were tumor infiltration or edema (n = 9), intradiverticular papilla (n = 2), pre-existing duodenal stent (n = 1), and anatomic anomalies (n = 3). Successful EUS-guided bile duct puncture and wire passage were achieved in all 15 patients (100 %), with drainage being successful in 12 / 15 (80 %). Failures occurred in three patients due to inability to traverse the biliary stricture (n = 2) or dissection of a choledochocele with the guide wire (n = 1); all were subsequently drained via percutaneous methods. Stents placed were metallic in eight patients and plastic in four. Complications consisted of moderate pancreatitis after a difficult ERCP attempt in one patient, and bacteremia after percutaneous biliary drainage in another. There were no instances of perforation, extraluminal air or fluid collections. EUS-assisted biliary drainage utilizing a transduodenal rendezvous approach demonstated a high success rate without any complications directly attributable to the EUS access. Advantages over percutaneous biliary and other methods of EUS biliary access include performance under the same

  8. Endoscopic ultrasound elastography for evaluation of lymph nodes and pancreatic masses: a multicenter study.

    Science.gov (United States)

    Giovannini, Marc; Thomas, Botelberge; Erwan, Bories; Christian, Pesenti; Fabrice, Caillol; Benjamin, Esterni; Geneviève, Monges; Paolo, Arcidiacono; Pierre, Deprez; Robert, Yeung; Walter, Schimdt; Hanz, Schrader; Carl, Szymanski; Christoph, Dietrich; Pierre, Eisendrath; Jean-Luc, Van Laethem; Jacques, Devière; Peter, Vilmann; Andrian, Saftoiu

    2009-04-07

    To evaluate the ability of endoscopic ultrasound (EUS) elastography to distinguish benign from malignant pancreatic masses and lymph nodes. A multicenter study was conducted and included 222 patients who underwent EUS examination with assessment of a pancreatic mass (n = 121) or lymph node (n = 101). The classification as benign or malignant, based on the real time elastography pattern, was compared with the classification based on the B-mode EUS images and with the final diagnosis obtained by EUS-guided fine needle aspiration (EUS-FNA) and/or by surgical pathology. An interobserver study was performed. The sensitivity and specificity of EUS elastography to differentiate benign from malignant pancreatic lesions are 92.3% and 80.0%, respectively, compared to 92.3% and 68.9%, respectively, for the conventional B-mode images. The sensitivity and specificity of EUS elastography to differentiate benign from malignant lymph nodes was 91.8% and 82.5%, respectively, compared to 78.6% and 50.0%, respectively, for the B-mode images. The kappa coefficient was 0.785 for the pancreatic masses and 0.657 for the lymph nodes. EUS elastography is superior compared to conventional B-mode imaging and appears to be able to distinguish benign from malignant pancreatic masses and lymph nodes with a high sensitivity, specificity and accuracy. It might be reserved as a second line examination to help characterise pancreatic masses after negative EUS-FNA and might increase the yield of EUS-FNA for lymph nodes.

  9. Ultrasound-Guided Transoral Videolaryngoscopic Surgery for Retropharyngeal Lymph Node Metastasis of Papillary Thyroid Cancer

    Directory of Open Access Journals (Sweden)

    Kazunori Fujiwara

    2017-07-01

    Full Text Available Background: Endoscopic-assisted transoral surgery, including transoral robotic surgery for metastatic retropharyngeal lymph node (RPN from well-differentiated thyroid cancer, has been reported to reduce the complications resulting from transcervical and transmandibular approaches. However, the narrow working space and difficulty identifying RPN are problematic. To solve these issues, several studies have used intraoperative ultrasound in endoscopic-assisted transoral surgery. However, the type of ultrasonography suitable for this purpose remains unclear. Case Presentation: A 60-year-old female with thyroid papillary carcinoma (T4aN1bM0 initially underwent total thyroidectomy and paratracheal and selective neck dissections (D2a, with resectional management of recurrent laryngeal nerve, trachea, and esophagus. Three years later, she was diagnosed with left retropharyngeal and upper mediastinal lymph node metastases of papillary thyroid cancer. Transoral videolaryngoscopic surgery was performed with a combination of ultrasonography with a flexible laparoscopic transducer manipulated with forceps for identifying RPN intraoperatively. Due to the transducer’s small size and thin, flexible cable, the transducer interrupted the procedure in spite of the narrowness of oral cavity. RPN was resected completely without adverse events. Conclusion: We performed intraoperative ultrasound-guided endoscopic transoral surgery for metastatic RPN from papillary thyroid cancer and achieved complete resection as well as preservation of swallowing function.

  10. Transvaginal Ultrasound-Guided Aspiration of Pelvic Abscesses

    Directory of Open Access Journals (Sweden)

    P. J. Corsi

    1999-01-01

    Full Text Available Objective: To assess the utility of a less invasive approach to the care of women with a pelvic abscess, we retrospectively reviewed the outcome of women with pelvic abscesses managed by transvaginal ultrasound-guided aspiration.

  11. Endoscopic ultrasound, endoscopic sonoelastography, and strain ratio evaluation of lymph nodes with histology as gold standard

    DEFF Research Database (Denmark)

    Larsen, Michael Hareskov; Fristrup, Claus Wilki; Hansen, Tine Plato

    2012-01-01

    . Endoscopic sonoelastography (ESE) assesses the elasticity of lymph nodes and has been used to differentiate lymph nodes with promising results. The aim of this study was to evaluate the use of EUS, EUS - FNA, ESE, and ESE-strain ratio using histology as the gold standard. PATIENTS AND METHODS: Patients......, EUS - FNA and EUS - FNM were performed. The marked lymph node was isolated during surgery for histological examination. RESULTS: The marked lymph node was isolated for separate histological examination in 56 patients, of whom 22 (39 %) had malignant lymph nodes and 34 (61 %) had benign lymph nodes...... - FNM technique enabled the identification of a specific lymph node and thereby the use of histology as gold standard. ESE and ESE-strain ratio were no better than standard EUS in differentiating between malignant and benign lymph nodes in patients with resectable upper gastrointestinal cancer....

  12. Endoscopic ultrasound for the characterization and staging of rectal cancer. Current state of the method. Technological advances and perspectives.

    Science.gov (United States)

    Gersak, Mariana M; Badea, Radu; Graur, Florin; Hajja, Nadim Al; Furcea, Luminita; Dudea, Sorin M

    2015-06-01

    Endoscopic ultrasound is the most accurate type of examination for the assessment of rectal tumors. Over the years, the method has advanced from gray-scale examination to intravenous contrast media administration and to different types of elastography. The multimodal approach of tumors (transrectal, transvaginal) is adapted to each case. 3D ultrasound is useful for spatial representation and precise measurement of tumor formations, using CT/MR image reconstruction; color elastography is useful for tumor characterization and staging; endoscopic ultrasound using intravenous contrast agents can help study the amount of contrast agent targeted at the level of the tumor formations and contrast wash-in/wash-out time, based on the curves displayed on the device. The transvaginal approach often allows better visualization of the tumor than the transrectal approach. Performing the procedure with the rectal ampulla distended with contrast agent may be seen as an optimization of the examination methodology. All these aspects are additional methods for gray-scale endoscopic ultrasound, capable of increasing diagnostic accuracy. This paper aims at reviewing the progress of transrectal and transvaginal ultrasound, generically called endoscopic ultrasound, for rectal tumor diagnosis and staging, with emphasis on the current state of the method and its development trends.

  13. Clinical value analysis of routine ultrasound combined with endoscopic ultrasonography in judging ulcerative colitis

    Directory of Open Access Journals (Sweden)

    Jing-Mei Tuo

    2016-01-01

    Full Text Available Objective: To study the clinical value of routine ultrasound combined with endoscopic ultrasonography in judging ulcerative colitis. Methods: A total of 60 cases of patients with ulcerative colitis were collected as observation group of research and 60 cases of healthy volunteers were collected as control group of research. Intestinal wall thickness was detected by white light endoscopy, abdominal intestinal ultrasound and endoscopic ultrasonography; TNF-α, IL-1β, IL-4 and IL-10 contents were detected by Elisa kit; Th1, Th2, Th17 and Treg ratios were detected by flow cytometry. Results: (1 intestinal wall thickness: intestinal wall thickness of both active UC patients and quiescent UC patients was significantly higher than that of control group, intestinal wall thickness of active UC patients was significantly higher than that of quiescent UC patients and the higher the degree of activity, the higher the intestinal wall thickness; (2 inflammatory mediators: TNF-α and IL-1β contents in intestinal mucosa of active UC patients were higher than those of quiescent UC patients and positively correlated with intestinal wall thickness; IL-4 and IL-10 contents were lower than those of quiescent UC patients and negatively correlated with intestinal wall thickness; (3 T cell contents: Th1 and Th17 cell contents in intestinal mucosa of active UC patients were higher than those of quiescent UC patients and positively correlated with intestinal wall thickness; Th2 and Treg cell contents in intestinal mucosa of active UC patients were lower than those of quiescent UC patients and negatively correlated with intestinal wall thickness. Conclusion: Routine ultrasound combined with endoscopic ultrasonography can accurately determine the severity of ulcerative colitis; measured intestinal wall thickness is closely correlated with the degree of inflammation and abnormal immune response.

  14. Endoscopic Ultrasonography-Guided Techniques for Accessing and Draining the Biliary System and the Pancreatic Duct.

    Science.gov (United States)

    Rimbaş, Mihai; Larghi, Alberto

    2017-10-01

    When endoscopic retrograde cholangiopancreatography (ERCP) fails to decompress the biliary system or the pancreatic duct, endoscopic ultrasonography (EUS)-guided biliary or pancreatic access and drainage can be used. Data show a high success rate and acceptable adverse event rate for EUS-guided biliary drainage. The outcomes of EUS-guided biliary drainage seem equivalent to percutaneous drainage and ERCP, whereas only retrospective studies are available for pancreatic duct drainage. In this article, revision of the technical and clinical status and the current evidence of interventional EUS-guided biliary and pancreatic duct access and drainage are presented. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Acupuncture sensation during ultrasound guided acupuncture needling

    Science.gov (United States)

    Park, Jongbae J.; Akazawa, Margeaux; Ahn, Jaeki; Beckman-Harned, Selena; Lin, Feng-Chang; Lee, Kwangjae; Fine, Jason; Davis, Robert T; Langevin, Helene

    2014-01-01

    Background Although acupuncture sensation (also known as de qi) is a cornerstone of traditional acupuncture therapy, most research has accepted the traditional method of defining acupuncture sensation only through subjective patient reports rather than on any quantifiable physiological basis. Purpose To preliminarily investigate the frequency of key sensations experienced while needling to specific, quantifiable tissue levels (TLs) guided by ultrasound (US) imaging. Methods Five participants received needling at two acupuncture points and two control points at four TLs. US scans were used to determine when each TL was reached. Each volunteer completed 32 sets of modified Southampton Needle Sensation Questionnaires. Part one of the study tested sensations experienced at each TL and part two compared the effect of oscillation alone versus oscillation + rotation. Results In all volunteers, the frequency of pricking, sharp sensations was significantly greater in shallower TLs than deeper (p=0.007); the frequency of sensations described as deep, dull and heavy, as spreading, and as electric shocks was significantly greater in deeper TLs than shallower (p=0.002). Sensations experienced did not significantly differ between real and control points within each of three TLs (p>0.05) except TL 4 (p=0.006). The introduction of needle rotation significantly increased deep, dull, heavy sensations, but not pricking and sharp sensations; within each level, the spectrum of sensation experienced during both oscillation + rotation and oscillation alone did not significantly differ between acupuncture and control points. Conclusion The preliminary study indicates a strong connection between acupuncture sensation and both tissue depth and needle rotation. Furthermore, the new methodology has been proven feasible. A further study with an objective measurement is warranted. PMID:21642648

  16. Comparison of ultrasound-guided versus anatomical landmark ...

    African Journals Online (AJOL)

    Background Femoral vein cannulation may be required during major surgery in infants and children and may prove to be life saving under certain conditions. This study compared ultrasound (US)-guided cannulation of the femoral vein in infants with the traditional anatomical landmark-guided technique. Methods Eighty ...

  17. A review of transrectal ultrasound guided prostate biopsies: Is there ...

    African Journals Online (AJOL)

    Objective: We compared our institution's initial experience with transrectal ultrasound-guided (TRUS) prostate biopsies in a single arm prospective study to a historical cohort of finger guided (FG) biopsies. The primary outcome measure was prostate cancer detection. We documented our findings on TRUS including the ...

  18. ultrasound-guided shoulder arthrogram injection

    African Journals Online (AJOL)

    2008-10-15

    Oct 15, 2008 ... Using an aseptic technique and without moving the ultrasound transducer from the desired transverse plane, the needle is advanced into the joint space through the rotator cuff interval, using real-time ultrasound guidance (Fig.2). The needle is inserted into the shoulder approximately midway between the ...

  19. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    International Nuclear Information System (INIS)

    Kim, You Me; Park, Hee Boong; Ryu, Jin Woo

    2005-01-01

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images

  20. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Me [Dankook University Hospital, Seoul (Korea, Republic of); Park, Hee Boong [Park Breast Clinic, Seoul (Korea, Republic of); Ryu, Jin Woo [Cheonan Choongmu Hospital, Cheonan (Korea, Republic of)

    2005-08-15

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images.

  1. Ultrasound-guided core needle biopsy for breast cancer

    International Nuclear Information System (INIS)

    Naqvi, S.Q.H.; Solangi, R.A.; Memon, M.; Solangi, R.A.

    2008-01-01

    To evaluate the efficacy of ultrasound-guided core needle biopsy (US-CNB) as a preoperative diagnostic modality for breast cancer. Females with solid and/or intermediate breast lesions visualized on ultrasonography. Apart from clinical work-up, all the above mentioned patients underwent ultrasound-guided core needle biopsy and excisional biopsy of their breast lesions. The histopathological diagnosis on ultrasound-guided core needle biopsy was then compared with the findings of the excisional biopsy. Out of the total 93 cases, 47(50.5%) had benign lesions on ultrasound; US-CNB showed 24 as fibroadenomata, four with chronic non-specific mastitis, five chronic suppurative mastitis, one tuberculosis, four fat necrosis, two lactational adenoma and seven cases with benign ductal hyperplasia without atypia. Nine (9.7%) cases showed suspicious abnormality on ultrasound; US-CNB revealed five cases with atypical ductal hyperplasia, one ductal carcinoma in situ and three invasive ductal carcinoma. Thirty seven (39.8%) cases were highly suggestive of malignancy on ultrasound; US-CNB showed 34 as invasive ductal carcinoma, two invasive lobular and one medullary carcinoma. Excisional biopsy confirmed the diagnosis of ultrasound-guided core needle biopsy in all cases except four; one case of chronic suppurative mastitis was diagnosed as that of tuberculosis and three cases of atypial ductal hyperplasia as invasive ductal carcinoma. Hence there was no false positive case, but four (4.3%) false negative cases. The sensitivity of the US-CNB was thus 100% and specificity 91.1%. Ultrasound guided core needle biopsy is a satisfactory procedure for the histopathological diagnosis of breast lesions. Any unsatisfactory, suspicious or atypical change on US-CNB should be followed by an open biopsy. (author)

  2. Ultrasound-guided drug delivery in cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chowdhury, Sayan Mullick; Lee, Tae Hwa; Willmann, Jugen K. [Dept. of Radiology, Stanford University School of Medicine, Stanford (United States)

    2017-07-15

    Recent advancements in ultrasound and microbubble (USMB) mediated drug delivery technology has shown that this approach can improve spatially confined delivery of drugs and genes to target tissues while reducing systemic dose and toxicity. The mechanism behind enhanced delivery of therapeutics is sonoporation, the formation of openings in the vasculature, induced by ultrasound-triggered oscillations and destruction of microbubbles. In this review, progress and challenges of USMB mediated drug delivery are summarized, with special focus on cancer therapy.

  3. Ultrasound-guided drug delivery in cancer

    Directory of Open Access Journals (Sweden)

    Sayan Mullick Chowdhury

    2017-07-01

    Full Text Available Recent advancements in ultrasound and microbubble (USMB mediated drug delivery technology has shown that this approach can improve spatially confined delivery of drugs and genes to target tissues while reducing systemic dose and toxicity. The mechanism behind enhanced delivery of therapeutics is sonoporation, the formation of openings in the vasculature, induced by ultrasound-triggered oscillations and destruction of microbubbles. In this review, progress and challenges of USMB mediated drug delivery are summarized, with special focus on cancer therapy.

  4. The future perspectives in transrectal prostate ultrasound guided biopsy

    Directory of Open Access Journals (Sweden)

    Sung Il Hwang

    2014-12-01

    Full Text Available Prostate cancer is one of the most common neoplasms in men. Transrectal ultrasound (TRUS-guided systematic biopsy has a crucial role in the diagnosis of prostate cancer. However, it shows limited value with gray-scale ultrasound alone because only a small number of malignancies are visible on TRUS. Recently, new emerging technologies in TRUS-guided prostate biopsy were introduced and showed high potential in the diagnosis of prostate cancer. High echogenicity of ultrasound contrast agent reflect the increased status of angiogenesis in tumor. Molecular imaging for targeting specific biomarker can be also used using ultrasound contrast agent for detecting angiogenesis or surface biomarker of prostate cancer. The combination of TRUS-guided prostate biopsy and ultrasound contrast agents can increase the accuracy of prostate cancer diagnosis. Elastography is an emerging ultrasound technique that can provide the information regarding tissue elasticity and stiffness. Tumors are usually stiffer than the surrounding soft tissue. In two types of elastography techniques, shearwave elastography has many potential in that it can provide quantitative information on tissue elasticity. Multiparametric magnetic resonance imaging (MRI from high resolution morphologic and functional magnetic resonance (MR technique enables to detect more prostate cancers. The combination of functional techniques including apparent diffusion coefficient map from diffusion weighted imaging, dynamic contrast enhanced MR and MR spectroscopy are helpful in the localization of the prostate cancer. MR-ultrasound (US fusion image can enhance the advantages of both two modalities. With MR-US fusion image, targeted biopsy of suspicious areas on MRI is possible and fusion image guided biopsy can provide improved detection rate. In conclusion, with recent advances in multiparametric-MRI, and introduction of new US techniques such as contrast-enhanced US and elastography, TRUS-guided biopsy

  5. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  6. Guiding tissue regeneration with ultrasound in vitro and in vivo

    Science.gov (United States)

    Dalecki, Diane; Comeau, Eric S.; Raeman, Carol H.; Child, Sally Z.; Hobbs, Laura; Hocking, Denise C.

    2015-05-01

    Developing new technologies that enable the repair or replacement of injured or diseased tissues is a major focus of regenerative medicine. This paper will discuss three ultrasound technologies under development in our laboratories to guide tissue regeneration both in vitro and in vivo. A critical obstacle in tissue engineering is the need for rapid and effective tissue vascularization strategies. To address this challenge, we are developing acoustic patterning techniques for microvascular tissue engineering. Acoustic radiation forces associated with ultrasound standing wave fields provide a rapid, non-invasive approach to spatially pattern cells in three dimensions without affecting cell viability. Acoustic patterning of endothelial cells leads to the rapid formation of microvascular networks throughout the volumes of three-dimensional hydrogels, and the morphology of the resultant microvessel networks can be controlled by design of the ultrasound field. A second technology under development uses ultrasound to noninvasively control the microstructure of collagen fibers within engineered tissues. The microstructure of extracellular matrix proteins provides signals that direct cell functions critical to tissue regeneration. Thus, controlling collagen microfiber structure with ultrasound provides a noninvasive approach to regulate the mechanical properties of biomaterials and control cellular responses. The third technology employs therapeutic ultrasound to enhance the healing of chronic wounds. Recent studies demonstrate increased granulation tissue thickness and collagen deposition in murine dermal wounds exposed to pulsed ultrasound. In summary, ultrasound technologies offer noninvasive approaches to control cell behaviors and extracellular matrix organization and thus hold great promise to advance tissue regeneration in vitro and in vivo.

  7. Efficacy of an artificial neural network-based approach to endoscopic ultrasound elastography in diagnosis of focal pancreatic masses

    DEFF Research Database (Denmark)

    Săftoiu, Adrian; Vilmann, Peter; Gorunescu, Florin

    2012-01-01

    By using strain assessment, real-time endoscopic ultrasound (EUS) elastography provides additional information about a lesion's characteristics in the pancreas. We assessed the accuracy of real-time EUS elastography in focal pancreatic lesions using computer-aided diagnosis by artificial neural...... network analysis....

  8. Endoscopic Ultrasound Fine-Needle Aspiration Characteristics of Primary Adenocarcinoma versus Other Malignant Neoplasms of The Pancreas

    Directory of Open Access Journals (Sweden)

    Veronika Gagovic

    2012-01-01

    Full Text Available BACKGROUND: Endoscopic ultrasound (EUS with fine-needle aspiration (FNA is often used to assist in the evaluation of pancreatic lesions and may help to diagnose benign versus malignant neoplasms. However, there is a paucity of literature regarding comparative EUS characteristics of various malignant pancreatic neoplasms (primary and metastatic.

  9. Endoscopic ultrasound

    DEFF Research Database (Denmark)

    Dietrich, Christoph F; Jenssen, Christian; Arcidiacono, Paolo G

    2015-01-01

    become a reality due to elastography, which is a recently developed technique. Elastography has already been proving its added value as a complementary imaging method, helpful to better characterize and differentiate between benign and malignant masses. The current applications of elastography in lymph...

  10. Ultrasound guided reduction of childhood intussusception

    International Nuclear Information System (INIS)

    Yoon, Chong Hyun; Kim, Han Suk

    1986-01-01

    Following on from diagnosis using ultrasound, hydrostatic reduction using saline enema under ultrasound guidance was tried in 20 cases of childhood intussusception. The conclusions were as follows: 1. Success rates of saline enema under ultrasound guidance during a first-8 month period (P1) and a second-10 month period (P2) were 55.6% (5/9) and 54.5% (6/11) respectively. Average success rate was 55% (11/20). 2. During the periods of P1 and P2, no case was reduced by barium enema in 6 cases of failed reduction with saline enema. 3. During the period of P2, 5 cases of successful reduction with saline enema were confirmed by clinical follow-up without barium enema. 4. During the periods of P1 and P2, 9 cases of failed reduction with saline enema were operated, resulting in 6 cases of segmental resection and 3 cases of manual reduction. 5. The obvious advantages of this method are: 1. No radiation hazard. 2. No fear of barium peritonitis. 3. Detection of leading point. 6. With above results, this method could completely replace barium enema. And ultrasonography should be the initial study in the evaluation of intussusception in children and then if necessary, saline enema under ultrasound guidance should be done.

  11. MRI-guided vacuum-assisted breast biopsy: comparison with stereotactically guided and ultrasound-guided techniques

    Energy Technology Data Exchange (ETDEWEB)

    Imschweiler, Thomas; Freiwald, Bianka; Kubik-Huch, Rahel A. [Kantonspital Baden AG, Institute for Radiology, Baden (Switzerland); Haueisen, Harald [Kantonspital Aarau AG, Institute for Radiology, Aarau (Switzerland); Kampmann, Gert [Clinica Sant' Anna, Lugano, Sorengo (Switzerland); Rageth, Luzi [Adjumed Services AG, Zurich (Switzerland); Seifert, Burkhardt [Institute for Social and Preventive Medicine, University of Zurich, Division of Biostatistics, Zuerich (Switzerland); Rageth, Christoph [Breast Centre, Zurich (Switzerland)

    2014-01-15

    To analyse the development of MRI-guided vacuum-assisted biopsy (VAB) in Switzerland and to compare the procedure with stereotactically guided and ultrasound-guided VAB. We performed a retrospective analysis of VABs between 2009 and 2011. A total of 9,113 VABs were performed. Of these, 557 were MRI guided. MRI-guided VAB showed the highest growth rate (97 %) of all three procedures. The technical success rates for MRI-guided, stereotactically guided and ultrasound-guided VAB were 98.4 % (548/557), 99.1 % (5,904/5,960) and 99.6 % (2,585/2,596), respectively. There were no significant differences (P = 0.12) between the MRI-guided and the stereotactically guided procedures. The technical success rate for ultrasound-guided VAB was significantly higher than that for MRI-guided VAB (P < 0.001). There were no complications using MRI-guided VAB requiring open surgery. The malignancy diagnosis rate for MRI-guided VAB was similar to that for stereotactically guided VAB (P = 0.35). MRI-guided VAB is a safe and accurate procedure that provides insight into clinical breast findings. (orig.)

  12. Amoebic liver abscess: Drained by ultrasound guided percutaneous ...

    African Journals Online (AJOL)

    Summary: Amoebic Liver Abscess in a 20-month-old child: A case of amoebic liver abscess in a Nigerian child is presented. Management consisted of 10days course of Metronidazole and 5days course of Tinidazole without improvement. This was followed by four sessions of ultrasound guided percutaneous needle ...

  13. Ultrasound-guided wire localization of lesions detected on ...

    African Journals Online (AJOL)

    Background: Wire localization for planned surgical treatment in the management of breast cancer is underutilized in our environment. The objective of this study is to assess the role of ultrasound-guided wire localization of breast masses detected on screening mammography and its impact on biopsy and breast ...

  14. A retrospective analysis of ultrasound-guided large core needle ...

    African Journals Online (AJOL)

    A retrospective analysis of ultrasound-guided large core needle biopsies of breast lesions at a regional public hospital in Durban, KwaZulu-Natal, South Africa. ... Objective: To assess the influence of technical variables on the diagnostic yield of breast specimens obtained by using US-LCNB, and the sensitivity of detecting ...

  15. Ultrasound-guided continuous phrenic nerve block for persistent hiccups.

    NARCIS (Netherlands)

    Renes, S.H.; Geffen, G.J. van; Rettig, H.C.; Gielen, M.J.M.; Scheffer, G.J.

    2010-01-01

    BACKGROUND: Phrenic nerve block can be performed and repeated if necessary for persistent hiccups, when conservative and pharmacological treatment is unsuccessful. We report the first description of an in-plane ultrasound (US)-guided phrenic nerve block (PhNB) with a catheter, after US investigation

  16. Ultrasound-guided nerve block for inguinal hernia repair

    DEFF Research Database (Denmark)

    Bærentzen, Finn; Maschmann, Christian; Jensen, Kenneth

    2012-01-01

    Open inguinal hernia repair in adults is considered a minor surgical procedure but can be associated with significant pain. We aimed to evaluate acute postoperative pain management in male adults randomized to receive an ultrasound-guided ilioinguinal and iliohypogastric nerve block administered...

  17. Ultrasound-guided needle aspiration of parotid abscess

    Directory of Open Access Journals (Sweden)

    André Takahashi

    2012-01-01

    Full Text Available Ultrasound (US has been used as a tool for parotid abscess diagnosis and treatment. The present article aimed to report a case of 72-year-old woman with parotid abscess treated by US-guided needle aspiration and conventional surgical drainage. Along with the clinical report, indications, advantages, and limitations of the method are discussed.

  18. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    2011-06-15

    Jun 15, 2011 ... guided PFNAB/US-guided PNCB was the diagnostic test in 23.33% cases. It confirmed a highly ..... provides guidance in multiple axial, longitudinal and .... Source of Support: Nil, Con.ict of Interest: None declared. Gani, et al.

  19. Real time elastography endoscopic ultrasound (RTE-EUS), a comprehensive review

    Energy Technology Data Exchange (ETDEWEB)

    Dietrich, C.F., E-mail: christoph.dietrich@ckbm.de [Med. Klinik 2, Caritas-Krankenhaus Bad Mergentheim (Germany); Department of Gastroenterology, Research Center of Gastroenterology and Hepatology, University of Medicine and Pharmacy of Craiova (Romania); Klinik für Innere Medizin, Krankenhaus Märkisch Oderland (Germany); Săftoiu, A.; Jenssen, C. [Med. Klinik 2, Caritas-Krankenhaus Bad Mergentheim (Germany); Department of Gastroenterology, Research Center of Gastroenterology and Hepatology, University of Medicine and Pharmacy of Craiova (Romania); Klinik für Innere Medizin, Krankenhaus Märkisch Oderland (Germany)

    2014-03-15

    Real-time elastography (RTE) performed during endoscopic ultrasound (EUS) is a relatively new technique which allows the evaluation of tissue stiffness, with the intent of better characterising lesions during EUS examinations. The aim of this comprehensive review was to describe the technique of RTE-EUS, as well as the clinical applications, including the study of pancreatic lesions, but also hepatobiliary, gastrointestinal (GI) tract pathology (including anal canal), lymph nodes, adrenal glands, lung and mediastinum, as well as urogenital applications. One of the advantages of the RTE-EUS technique is especially the possibility to be used in various locations accessible from the GI tract. Future developments are also briefly discussed, as elastography is a tissue characterising technique that will certainly not replace biopsy, but will rather be an adjunct during EUS examinations, due to its ease of use and low cost.

  20. Real time elastography endoscopic ultrasound (RTE-EUS), a comprehensive review

    International Nuclear Information System (INIS)

    Dietrich, C.F.; Săftoiu, A.; Jenssen, C.

    2014-01-01

    Real-time elastography (RTE) performed during endoscopic ultrasound (EUS) is a relatively new technique which allows the evaluation of tissue stiffness, with the intent of better characterising lesions during EUS examinations. The aim of this comprehensive review was to describe the technique of RTE-EUS, as well as the clinical applications, including the study of pancreatic lesions, but also hepatobiliary, gastrointestinal (GI) tract pathology (including anal canal), lymph nodes, adrenal glands, lung and mediastinum, as well as urogenital applications. One of the advantages of the RTE-EUS technique is especially the possibility to be used in various locations accessible from the GI tract. Future developments are also briefly discussed, as elastography is a tissue characterising technique that will certainly not replace biopsy, but will rather be an adjunct during EUS examinations, due to its ease of use and low cost

  1. Endoscopic and ultrasound diagnostics as contemporary method in diagnostics of dog stomach diseases

    Directory of Open Access Journals (Sweden)

    Krstić Vanja

    2005-01-01

    Full Text Available The visualization of pathological processes in the dog stomach determines a correct diagnosis or differential diagnosis, which presents the basic prerequisite for rational therapy. In addition to the conventional type of clinical examination which covers the taking of anamnestic data, observation of the patient and laboratory tests, there are also certain computerized diagnostic methods (magnetic resonance and scanner which are the most precise and most reliable in the verification of stomach diseases. However, the listed approaches are either insufficiently relevant in making the diagnosis or are too expensive and demanding for the everyday clinical practice. These are the reasons why veterinary medicine today increasingly resorts to the use of other forms of imaging diagnostics, and, as its representatives, the video endoscopic, ultrasound and X-ray examination of the digestive tract.

  2. Combining endoscopic ultrasound with Time-Of-Flight PET: The EndoTOFPET-US Project

    CERN Document Server

    Frisch, Benjamin

    2013-01-01

    The EndoTOFPET-US collaboration develops a multimodal imaging technique for endoscopic exams of the pancreas or the prostate. It combines the benefits of high resolution metabolic imaging with Time-Of-Flight Positron Emission Tomography (TOF PET) and anatomical imaging with ultrasound (US). EndoTOFPET-US consists of a PET head extension for a commercial US endoscope and a PET plate outside the body in coincidence with the head. The high level of miniaturization and integration creates challenges in fields such as scintillating crystals, ultra-fast photo-detection, highly integrated electronics, system integration and image reconstruction. Amongst the developments, fast scintillators as well as fast and compact digital SiPMs with single SPAD readout are used to obtain the best coincidence time resolution (CTR). Highly integrated ASICs and DAQ electronics contribute to the timing performances of EndoTOFPET. In view of the targeted resolution of around 1 mm in the reconstructed image, we present a prototype dete...

  3. Ultrasound probe and needle-guide calibration for robotic ultrasound scanning and needle targeting.

    Science.gov (United States)

    Kim, Chunwoo; Chang, Doyoung; Petrisor, Doru; Chirikjian, Gregory; Han, Misop; Stoianovici, Dan

    2013-06-01

    Image-to-robot registration is a typical step for robotic image-guided interventions. If the imaging device uses a portable imaging probe that is held by a robot, this registration is constant and has been commonly named probe calibration. The same applies to probes tracked by a position measurement device. We report a calibration method for 2-D ultrasound probes using robotic manipulation and a planar calibration rig. Moreover, a needle guide that is attached to the probe is also calibrated for ultrasound-guided needle targeting. The method is applied to a transrectal ultrasound (TRUS) probe for robot-assisted prostate biopsy. Validation experiments include TRUS-guided needle targeting accuracy tests. This paper outlines the entire process from the calibration to image-guided targeting. Freehand TRUS-guided prostate biopsy is the primary method of diagnosing prostate cancer, with over 1.2 million procedures performed annually in the U.S. alone. However, freehand biopsy is a highly challenging procedure with subjective quality control. As such, biopsy devices are emerging to assist the physician. Here, we present a method that uses robotic TRUS manipulation. A 2-D TRUS probe is supported by a 4-degree-of-freedom robot. The robot performs ultrasound scanning, enabling 3-D reconstructions. Based on the images, the robot orients a needle guide on target for biopsy. The biopsy is acquired manually through the guide. In vitro tests showed that the 3-D images were geometrically accurate, and an image-based needle targeting accuracy was 1.55 mm. These validate the probe calibration presented and the overall robotic system for needle targeting. Targeting accuracy is sufficient for targeting small, clinically significant prostatic cancer lesions, but actual in vivo targeting will include additional error components that will have to be determined.

  4. Ultrasound-guided biopsy and drainage

    International Nuclear Information System (INIS)

    Ott, R.C.; Wellauer, J.

    1985-01-01

    This book discusses the ultrasound (US) biopsy techniques, cytology, histology, and physics. The emphasis is on use of US guidance, as the authors find that virtually all lesions are visible at US scanning and they thus save valuable time on the computer tomographic scanner. The authors present in great detail their considerable work in designing needles that are readily visible at US scanning and can also collect good cytologic and histologic material. Biopsy techniques are discussed separately for each organ system. The accuracy of these techniques in over 3,000 of the author's cases is presented

  5. Ultrasound-guided central venous access using Google Glass.

    Science.gov (United States)

    Wu, Teresa S; Dameff, Christian J; Tully, Jeffrey L

    2014-12-01

    The use of ultrasound during invasive bedside procedures is quickly becoming the standard of care. Ultrasound machine placement during procedures often requires the practitioner to turn their head during the procedure to view the screen. Such turning has been implicated in unintentional hand movements in novices. Google Glass is a head-mounted computer with a specialized screen capable of projecting images and video into the view of the wearer. Such technology may help decrease unintentional hand movements. Our aim was to evaluate whether or not medical practitioners at various levels of training could use Google Glass to perform an ultrasound-guided procedure, and to explore potential advantages of this technology. Forty participants of varying training levels were randomized into two groups. One group used Google Glass to perform an ultrasound-guided central line. The other group used traditional ultrasound during the procedure. Video recordings of eye and hand movements were analyzed. All participants from both groups were able to complete the procedure without difficulty. Google Glass wearers took longer to perform the procedure at all training levels (medical student year 1 [MS1]: 193 s vs. 77 s, p > 0.5; MS4: 197s vs. 91s, p ≤ 0.05; postgraduate year 1 [PGY1]: 288s vs. 125 s, p > 0.5; PGY3: 151 s vs. 52 s, p ≤ 0.05), and required more needle redirections (MS1: 4.4 vs. 2.0, p > 0.5; MS4: 4.8 vs. 2.8, p > 0.5; PGY1: 4.4 vs. 2.8, p > 0.5; PGY3: 2.0 vs. 1.0, p > 0.5). In this study, it was possible to perform ultrasound-guided procedures with Google Glass. Google Glass wearers, on average, took longer to gain access, and had more needle redirections, but less head movements were noted. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Endobronchial ultrasound elastography: a new method in endobronchial ultrasound-guided transbronchial needle aspiration.

    Science.gov (United States)

    Jiang, Jun-Hong; Turner, J Francis; Huang, Jian-An

    2015-12-01

    TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS

  7. Ultrasound Guided Percutaneous Nephrostomy: Experience at ...

    African Journals Online (AJOL)

    Background: Obstructive uropathy is a common problem in urologic practice; temporary relief of obstruction in the upper tract poses a significant challenge. Ultrasound‑guided percutaneous nephrostomy (PCN) is an option for upper tract drainage; compared to fluoroscopic guidance, it is readily available, affordable, and not ...

  8. The comparative study of CT guided and ultrasound guided percutaneous ethanol injection in the treatment of intra-abdominal cyst

    International Nuclear Information System (INIS)

    Li Heping; Yang Jianyong; Chen Wei; Zhuang Wenquan; Huang Yulian; Chen Jianye

    2005-01-01

    Objective: An comparative study of the interventional approach of CT guided and ultiasound guided percutaneous ethanol injection(PEI) in the treatment of intra-abdominal cyst. Methods: CT guided PEI was performed in the treatment of intra-abdominal cyst in 38 patients while ultrasound guided PEI was performed in 45 cases. Results: The puncture procedure of CT guided PEI was totally performed 83 times in treating 56 intra-abdominal cysts in 38 patients and CT guided PEI was unsuccessful in 6 patients. The puncture procedure of ultrasound guided PEI were performed 87 times in treating 71 intra-abdominal cysts in 55 patients and ultrasound guided PEI only failed only in 1 patient. Conclusion: Ultrasound guided PEI is superior to CT guided PEI in the treatment of intra-abdominal cyst. (authors)

  9. Pre-puncture ultrasound guided epidural insertion before vaginal delivery.

    Science.gov (United States)

    Nassar, Mahmoud; Abdelazim, Ibrahim A

    2015-10-01

    Palpation method is widely used in clinical practice to identify the puncture site during combined spinal-epidural (CSE) blocks. Tuffier's line, is an anatomical landmark between two iliac crests (inter-cristal), which is widely used to identify the puncture site during CSE blocks is not always an indicator for specific vertebral level or inter-vertebral space. One hundred and Ten (110) women were scheduled for normal vaginal delivery and were randomized into two equal groups; palpation group and an ultrasound guided group to detect the efficacy of puncture ultrasound before CSE blocks to increase chances of successful CSE procedure on the first attempt and to reduce the number of attempts or punctures during insertion of CSE catheter. There were no significant differences between two studied groups regarding; maternal age, weight and height, while, there was a significant difference between two studied groups regarding; parity. Percentage of successful CSE procedure on the first attempt was significantly higher (67.27%) in ultrasound compared to palpation group (40%). Number of punctures (attempts) were significantly less in ultrasound (1.2 ± 0.6) compared to palpation group (2.3 ± 0.8) and the number of redirections was also significantly less in ultrasound (1.4 ± 0.5) compared to palpation group (2.8 ± 1.6). Although, time to identify puncture site was significantly longer in ultrasound compared to palpation group and total procedure time was longer in ultrasound (9.1 ± 1.5 min) compared to palpation group (6.2 ± 1.2 min), there was no significant difference between two studied groups regarding; time to identify puncture site and total procedure time. Two cases of dural puncture in palpation versus no cases in ultrasound group and two cases of intravascular catheter placement (one in each group), with no significant difference between two groups. Pre- puncture ultrasound guided epidural insertion before vaginal delivery, increases the chance of a

  10. Ultrasound-guided interventional therapy for recurrent ovarian chocolate cysts.

    Science.gov (United States)

    Wang, Lu-Lu; Dong, Xiao-Qiu; Shao, Xiao-Hui; Wang, Si-Ming

    2011-10-01

    The aim of this study was to determine the effectiveness of ultrasound-guided interventional therapy in the treatment of postoperative recurrent chocolate cysts. The 198 patients enrolled in this study were divided into three groups. In group 1, the saline washing group, the cavity of the cyst was washed thoroughly with warm saline. In group 2, the ethanol short-time retention group, after washing with saline, the cyst was injected with 95% ethanol with a volume of half of the fluid aspirated from the cyst. Ten minutes later, the rest of the ethanol was aspirated. In group 3, the ethanol retention group, the procedures were the same as with the ethanol short-time retention group, except that 95% of the ethanol was retained in the cyst. An ultrasound examination was performed in the third, sixth and 12th months after therapy. The chocolate cyst cure rate was significantly higher in the ethanol retention group (96%, 66/69) than in the ethanol short-time retention group (82%, 56/68) and no case was cured in the first group (saline washing). We conclude that ultrasound-guided injection and 95% ethanol retention are an effective therapy for the treatment of postoperative recurrent chocolate cysts. Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  11. Ultrasound guided aspiration cytology of neck mass except thyroid mass

    International Nuclear Information System (INIS)

    Kim, Myeong Jin; Lee, Jong Tae; Yoo, Hyung Sik; Suh, Jung Ho; Park, Cheong Soo; Lee, Gwang Gil

    1988-01-01

    Results of ultrasound guided aspiration cytology of extrathyroidal neck masses of 73 patients were reviewed. Included cases were 23 malignant lesions; 16 metastatic tumors, 4 lymphomas, 3 salivary gland tumors and 50 benign lesions: 24 tuberculous lymphadenites, 15 abscess, 3 benign lymph node hyperplasias, etc. There were one case of false negative and none of false positive result for malignancy. In two cases of malignancy, insufficient cellular material was obtained. In one case of lymphoma, and a benign lymph node hyperplasia, it was difficult to distinguish between benignancy and malignancy on cytologic smear. For the malignant lesions, sensitivity was 83%, specificity was 98%, and overall accuracy was 93%. There were none who had suffered adverse effect from the procedure. Ultrasound guided aspiration cytology seems to be simple, accurate and safe diagnostic modality for neck masses especially in condition that malignancy can not be excluded

  12. Ultrasound-guided antegrade pyelography of renal transplants

    International Nuclear Information System (INIS)

    Wernecke, K.; Heckemann, R.; Rehwald, U.; Ringert, R.H.; Essen Univ.

    1983-01-01

    The indications for, and technique of, ultrasound-guided antegrade pyelography of renal transplants are illustrated by eight patients. Because of the detailed anatomical information which the antegrade method provides, it is superior to other diagnostic methods for the investigation of ureteric obstruction or fistulae. The severity of renal pelvis dilatation as shown by sonography must not be taken as a criterian for the grade of obstruction, since transplants may show dilated collecting systems, even in the absence of obstruction. In our view, real time sonography with a suitable probe provides the best means of achieving successful puncture of the renal pelvis. The combination of ultrasound-guided puncture and radiological contrast examination of the ureter is the best diagnostic method available and lead, in all eight cases, to immediate and definitive treatment. (orig.)

  13. Ultrasound-guided genitourinary interventions: principles and techniques

    Directory of Open Access Journals (Sweden)

    Byung Kwan Park

    2017-10-01

    Full Text Available Ultrasound (US is often used to guide various interventional procedures in the genitourinary (GU tract because it can provide real-time imaging without any radiation hazard. Moreover, US can clearly visualize the pathway of an aspiration or biopsy needle to ensure the safety of the intervention. US guidance also helps clinicians to access lesions via the transabdominal, transhepatic, transvaginal, transrectal, and transperineal routes. Hence, US-guided procedures are useful for radiologists who wish to perform GU interventions. However, US-guided procedures and interventions are difficult for beginners because they involve a steep initial learning curve. The purpose of this review is to describe the basic principles and techniques of US-guided GU interventions.

  14. An ultrasound needle insertion guide in a porcine phantom model.

    Science.gov (United States)

    Whittaker, S; Lethbridge, G; Kim, C; Keon Cohen, Z; Ng, I

    2013-08-01

    We compared nerve blockade with and without the Infiniti(TM) needle guide in an ultrasound in-plane porcine simulation. We recruited 30 anaesthetists with varying blockade experience. Using the guide, the needle tip was more visible (for a median (IQR [range]) of 67 (56-100]) % of the time; and invisible for 2 (1-4 [0-19]) s) than when the guide was not used (respectively 23 (13-43 [0-80]) % and 25 (9-52 [1-198]) s; both p < 0.001). The corresponding block times were 8 (6-10 [3-28]) s and 32 (15-67 [5-225]) s, respectively; p < 0.001. The needle guide reduced the block time and the time that the needle was invisible, irrespective of anaesthetist experience. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  15. Ultrasound-guided genitourinary interventions: principles and techniques

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byung Kwan [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-10-15

    Ultrasound (US) is often used to guide various interventional procedures in the genitourinary (GU) tract because it can provide real-time imaging without any radiation hazard. Moreover, US can clearly visualize the pathway of an aspiration or biopsy needle to ensure the safety of the intervention. US guidance also helps clinicians to access lesions via the transabdominal, transhepatic, transvaginal, transrectal, and transperineal routes. Hence, US-guided procedures are useful for radiologists who wish to perform GU interventions. However, US-guided procedures and interventions are difficult for beginners because they involve a steep initial learning curve. The purpose of this review is to describe the basic principles and techniques of US-guided GU interventions.

  16. Endoscopic ultrasound with double-balloon endoscopy for the diagnosis of inverted Meckel’s diverticulum: a case report

    Directory of Open Access Journals (Sweden)

    Araki Akihiro

    2012-09-01

    Full Text Available Abstract Introduction Inverted Meckel’s diverticulum has usually been misdiagnosed in the cases based on computed tomography images presented in the literature. The final diagnosis was made intra-operatively or by pathology reports after surgery. Despite this, preoperative diagnosis could be made successfully by using endoscopic ultrasound with double-balloon endoscopy prior to surgery. Case presentation A 60-year-old Japanese woman with severe anemia complained of several episodes of black stool over the preceding 2 years. Abdominal computed tomography showed a 3.0-cm low-density tumor in the ileum, suggesting a diagnosis of intestinal lipoma. Examination of the tumor by endoscopic ultrasound with double-balloon endoscopy revealed a hypo-echoic layer corresponding to the muscularis propria, and a hyper-echoic layer corresponding to the fat tissue. These findings, which suggested that the tumor included areas outside the intestinal serosa, are not typical for a lipoma, despite the existence of a hyper-echoic layer corresponding to fatty tissue. We then considered a diagnosis of inverted Meckel’s diverticulum. Conclusion Lipoma and inverted Meckel’s diverticulum are difficult to differentially diagnose by computed tomography. Polypectomy is the preferred therapeutic approach when a lipoma is present; however, polypectomy in a patient with Meckel’s diverticulum requires full-thickness resection. Situations where polypectomy is performed without preparing for full-thickness resection can be avoided by first making a precise diagnosis using double-balloon endoscopy and endoscopic ultrasound.

  17. Faculty staff-guided versus self-guided ultrasound training for internal medicine residents.

    Science.gov (United States)

    Alba, George A; Kelmenson, Daniel A; Noble, Vicki E; Murray, Alice F; Currier, Paul F

    2013-11-01

    Ultrasonography is of growing importance within internal medicine (IM), but the optimal method of training doctors to use it is uncertain. In this study, the authors provide the first objective comparison of two approaches to training IM residents in ultrasonography. In this randomised trial, a simulation-based ultrasound training curriculum was implemented during IM intern orientation at a tertiary care teaching hospital. All 72 incoming interns attended a lecture and were given access to online modules. Interns were then randomly assigned to a 4-hour faculty-guided (FG) or self-guided (SG) ultrasound training session in a simulation laboratory with both human and manikin models. Interns were asked to self-assess their competence in ultrasonography and underwent an objective structured clinical examination (OSCE) to assess their competence in basic and procedurally oriented ultrasound tasks. The primary outcome was the score on the OSCE. Faculty-guided training was superior to self-guided training based on the OSCE scores. Subjects in the FG training group achieved significantly higher OSCE scores on the two subsets of task completion (0.9-point difference, 95% confidence interval [CI] 0.27-1.54; p = 0.008) and ultrasound image quality (2.43-point difference, 95% CI 1.5-3.36; p training groups demonstrated an increase in self-assessed competence after their respective training sessions and there was little difference between the groups. Subjects rated the FG training group much more favourably than the SG training group. Both FG and SG ultrasound training curricula can improve the self-reported competence of IM interns in ultrasonography. However, FG training was superior to SG training in both skills acquisition and intern preference. Incorporating mandatory ultrasound training into IM residencies can address the perceived need for ultrasound training, improve confidence and procedural skills, and may enhance patient safety. However, the optimal training method

  18. Ultrasound-guided peripheral and truncal blocks in pediatric patients

    Directory of Open Access Journals (Sweden)

    Mohamed Bilal Delvi

    2011-01-01

    Full Text Available Ultrasound has added a feather in the cap of the anesthesiologists as real-time nerve localization and drug deposition around the nerve structure under real-time guidance is now a reality, as the saying "seeing is believing" has been proven true with the advent of ultrasound in anesthesia. Pediatric patients are a unique group regarding their anatomical and physiological features in comparison with adults; regional blocks in adults with the anatomical landmark and surface marking are almost uniform across the adult population. The landmark technique in pediatric patients is not reliable in all patients due to the variability in the age and size; the advent of ultrasound in assisting nerve localization has changed the way regional blocks are achieved in children and the range of blocks performed on adults can now be performed on pediatric patients; with advances in the technology and dexterity of ultrasound equipment, the chances of success of blocks has increased with a smaller dose of the local anesthetic in comparison to the traditional methods. Anesthesiologists are now able to perform blocks with more accuracy and avoid complications like intravascular injection and injury to the pleura and peritoneum during routine practice with the assistance of high-frequency transducers and top of the range portable ultrasound machines; catheters can be inserted to provide a continuous analgesia in the postoperative period. This review article describes the common peripheral blocks in pediatric patients; the readers are encouraged to gain experience by attending workshops, hands-on practice under supervision, and conduct random controlled trials pertaining to ultrasound-guided blocks in the pediatric age group. The recent literature is encouraging and further research is promising; a wide range of blocks being described in detail by many prominent experts from all over the world.

  19. Ultrasound-guided antegrade access during laparoscopic pyeloplasty in infants less than one year of age: A point of technique

    Directory of Open Access Journals (Sweden)

    Arvind Ganpule

    2012-01-01

    Full Text Available Background: Access to urethras and ureters of infants may be hazardous and injurious through an endoscopic route. Placement and removal of stents in infants requires anaesthesia and access through these small caliber urethras. We describe our technique of placing antegrade splint during a laparoscopic pyeloplasty in these infants. Materials and Methods: An ultrasound-guided percutaneous renal access is obtained. Telescopic metal two part needle is passed into the kidney over a guide wire. A second guide wire is passed through the telescopic metal two part needle. The tract is dilated with 14 Fr screw dilator. Over one guide wire, a 5 Fr ureteric catheter is passed and coiled in the renal pelvis. Over the other wire, a 14 Fr malecot catheter is placed as nephrostomy. Laparoscopic pyeloplasty is then done. During pyelotomy, the ureteric catheter is pulled and advanced through the ureter before the pyeloplasty is completed. The ureteric catheter thus acts as a splint across the anastomosis. Ureteric catheter is removed on the 3 rd post operative day and nephrostomy is clamped. Nephrostomy is removed on 4 th post operative day if child is asymptomatic. The modified technique was successfully done in five patients aged less than one year old. All patients tolerated the procedure well. Post operative period was uneventful in all. Conclusion: Ultrasound-guided ante grade nephroureteral ureteral splint for infant laparoscopic pyeloplasty is safe. It avoids the need for urethral instrumentation for insertion and removal of stents in these small patients.

  20. Diagnostic accuracy of ultrasound, computed tomography, and endoscopic retrograde choleangiopancreatography in the detection of obstructive jaundice

    International Nuclear Information System (INIS)

    Pasanen, P.A.; Partainen, K.; Pikkarainen, P.; Alhava, E.; Pirinen, A.; Janatuinen, E.

    1991-01-01

    The purpose of this prospective study was to investigate the diagnostic accuracy of ultrasound (US), computed tomography (CT), and endoscopic retrograde cholangiopancreatography (ERCP) in the distinction between extrahepatic and intrahepatic causes of jaundice. The limit for the inclusion to the study was defined as a serum bilirubin concentration ≥40μmol/l. Altogether 187 jaundiced patients were studied. The sensitivities of US, CT and ERCP were 63%, 77%, and 87%, respectively. The differences between all these methods were statistically significant. The specificities and positive predictive values were high, reaching 96-99%, but the negative predictive values were low, ranging between 38% and 60%. Choledochal stone disease constituted the main etiology of false-negative studies in all investigations. Imaging procedures have a prominent role in the diagnostic study of the jaundiced patient, but it is obvious that their diagnostic accuracy may vary between institutions because of the variance in local experience and expertise and because of the differences in diseases causing jaundice. 37 refs., 5 tabs

  1. Endoscopic ultrasound with fine needle aspiration and biopsy in lung cancer and isolated mediastinal lymphadenopathy.

    LENUS (Irish Health Repository)

    Nadarajan, P

    2010-03-01

    Endoscopic ultrasound with fine-needle aspiration and biopsy (EUS-FNAB) is well established in diagnosing and staging lung cancer in patients with mediastinal adenopathy. EUS-FNAB is highly sensitive, less invasive and has lower complication rates when compared to surgical staging of mediastinal nodes. In this study we describe our experience of EUS-FNAB in lung cancer and other causes of mediastinal lymphadenopathy. EUS-FNAB was performed for assessment of PET positive mediastinal lymph nodes between January 2007 and March 2009 in AMNCH. The endpoints of our study were sensitivity and specificity of EUS-FNAB, morbidity and length of hospital stay. Thirty four patients underwent EUS-FNAB during the study period for both diagnosis and staging. Thirty patients had positive lymph node invasion and 4 had no evidence of malignant invasion. In these 4 patients negative cytology was confirmed on mediastinoscopy giving EUS-FNAB a sensitivity and specificity of 100%. EUS-FNAB upstaged the disease in 12 patients. EUS-FNAB is a reliable tool for mediastinal staging in lung cancer, significantly reducing the need for surgical staging procedures in patients with suspected mediastinal involvement.

  2. Dilation of Malignant Strictures in Endoscopic Ultrasound Staging of Esophageal Cancer and Metastatic Spread of Disease

    Directory of Open Access Journals (Sweden)

    Shawn M. Hancock

    2011-01-01

    Full Text Available Background. Dilation of malignant strictures in endoscopic ultrasound (EUS staging of esophageal cancer is safe, but no data exists regarding the subsequent development of metastases. Aim. Compare the rates of metastases in esophageal cancer patients undergoing EUS staging who require esophageal dilation in order to pass the echoendoscope versus those who do not. Methods. We reviewed consecutive patients referred for EUS staging of esophageal cancer. We evaluated whether dilation was necessary in order to pass the echoendoscope, and for the subsequent development of metastases after EUS at various time intervals. Results. Among all patients with similar stage (locally advanced disease, defined as T3, N0, M0 or T1-3, N1, M0, there was no difference between the dilated and nondilated groups in the rates of metastases at 3 months (14% versus 10%, =1.0, 6 months (28% versus 20%, =0.69, 12 months (43% versus 40%, =1.0, or ever during a mean followup of 15 months (71% versus 55%, =0.48. Conclusions. Dilation of malignant strictures for EUS staging of esophageal cancer does not appear to lead to higher rates of distant metastases.

  3. A novel ultrasound-guided shoulder arthroscopic surgery

    Science.gov (United States)

    Tyryshkin, K.; Mousavi, P.; Beek, M.; Chen, T.; Pichora, D.; Abolmaesumi, P.

    2006-03-01

    This paper presents a novel ultrasound-guided computer system for arthroscopic surgery of the shoulder joint. Intraoperatively, the system tracks and displays the surgical instruments, such as arthroscope and arthroscopic burrs, relative to the anatomy of the patient. The purpose of this system is to improve the surgeon's perception of the three-dimensional space within the anatomy of the patient in which the instruments are manipulated and to provide guidance towards the targeted anatomy. Pre-operatively, computed tomography images of the patient are acquired to construct virtual threedimensional surface models of the shoulder bone structure. Intra-operatively, live ultrasound images of pre-selected regions of the shoulder are captured using an ultrasound probe whose three-dimensional position is tracked by an optical camera. These images are used to register the surface model to the anatomy of the patient in the operating room. An initial alignment is obtained by matching at least three points manually selected on the model to their corresponding points identified on the ultrasound images. The registration is then improved with an iterative closest point or a sequential least squares estimation technique. In the present study the registration results of these techniques are compared. After the registration, surgical instruments are displayed relative to the surface model of the patient on a graphical screen visible to the surgeon. Results of laboratory experiments on a shoulder phantom indicate acceptable registration results and sufficiently fast overall system performance to be applicable in the operating room.

  4. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-05-15

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications.

  5. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    International Nuclear Information System (INIS)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu

    2017-01-01

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications

  6. Ultrasound-Guided Regional Anesthesia Simulation Training: A Systematic Review.

    Science.gov (United States)

    Chen, Xiao Xu; Trivedi, Vatsal; AlSaflan, AbdulHadi A; Todd, Suzanne Clare; Tricco, Andrea C; McCartney, Colin J L; Boet, Sylvain

    Ultrasound-guided regional anesthesia (UGRA) has become the criterion standard of regional anesthesia practice. Ultrasound-guided regional anesthesia teaching programs often use simulation, and guidelines have been published to help guide URGA education. This systematic review aimed to examine the effectiveness of simulation-based education for the acquisition and maintenance of competence in UGRA. Studies identified in MEDLINE, EMBASE, CINAHL, Cochrane Central Register of Controlled Trials, and ERIC were included if they assessed simulation-based UGRA teaching with outcomes measured at Kirkpatrick level 2 (knowledge and skills), 3 (transfer of learning to the workplace), or 4 (patient outcomes). Two authors independently reviewed all identified references for eligibility, abstracted data, and appraised quality. After screening 176 citations and 45 full-text articles, 12 studies were included. Simulation-enhanced training improved knowledge acquisition (Kirkpatrick level 2) when compared with nonsimulation training. Seven studies measuring skill acquisition (Kirkpatrick level 2) found that simulation-enhanced UGRA training was significantly more effective than alternative teaching methods or no intervention. One study measuring transfer of learning into the clinical setting (Kirkpatrick level 3) found no difference between simulation-enhanced UGRA training and non-simulation-based training. However, this study was discontinued early because of technical challenges. Two studies examined patient outcomes (Kirkpatrick level 4), and one of these found that simulation-based UGRA training improved patient outcomes compared with didactic teaching. Ultrasound-guided regional anesthesia knowledge and skills significantly improved with simulation training. The acquired UGRA skills may be transferred to the clinical setting; however, further studies are required to confirm these changes translate to improved patient outcomes.

  7. Guided interventions in musculoskeletal ultrasound: what's the evidence?

    International Nuclear Information System (INIS)

    Davidson, J.; Jayaraman, S.

    2011-01-01

    Increasing histological and radiological understanding of the processes involved in soft-tissue injury is leading to novel targeted treatments. A number of reviews have recommended that these treatments should be performed with image guidance. This review describes current ultrasound-guided interventions and injections, together with the level of evidence for these. Discussion of guided interventions will include; percutaneous lavage (barbotage), brisement, dry needling, electrocoagulation, and of guided injections; corticosteroids, autologous substances (blood and platelet rich plasma), sclerosants, and prolotherapy (hyperosmolar dextrose). Representative imaging illustrating some of these techniques is included for correlation with the methods described. As these procedures are often performed in sportspeople, it is essential that the radiologist is aware of prohibited substances and methods outlined in an annual publication from the World Anti-Doping Association (WADA). Finally, future directions, including the use of autologous substances, mesenchymal and stem cells will be discussed.

  8. Ultrasound-guided injection for plantar fasciitis: A brief review

    Directory of Open Access Journals (Sweden)

    A S Nair

    2016-01-01

    Full Text Available Plantar fasciitis (PF is a distressing condition experienced by many patients. Although self-limiting, it tends to become a chronic ailment if the precipitating factors are not addressed. One of the modality of treating PF is intra-lesional corticosteroid injection. This was done using palpation technique earlier but nowadays many specialists use ultrasound (US imaging as a guide to give injection accurately instead of inadvertently damaging the plantar fascia or injecting into surrounding soft tissue, both of which can have serious implications. We did a literature search in Medline, Scopus, and Embase databases to find out articles describing US-guided corticosteroid injection for treating PF and whether guided injection was effective than injection given by palpation.

  9. Robust electromagnetically guided endoscopic procedure using enhanced particle swarm optimization for multimodal information fusion

    International Nuclear Information System (INIS)

    Luo, Xiongbiao; Wan, Ying; He, Xiangjian

    2015-01-01

    Purpose: Electromagnetically guided endoscopic procedure, which aims at accurately and robustly localizing the endoscope, involves multimodal sensory information during interventions. However, it still remains challenging in how to integrate these information for precise and stable endoscopic guidance. To tackle such a challenge, this paper proposes a new framework on the basis of an enhanced particle swarm optimization method to effectively fuse these information for accurate and continuous endoscope localization. Methods: The authors use the particle swarm optimization method, which is one of stochastic evolutionary computation algorithms, to effectively fuse the multimodal information including preoperative information (i.e., computed tomography images) as a frame of reference, endoscopic camera videos, and positional sensor measurements (i.e., electromagnetic sensor outputs). Since the evolutionary computation method usually limits its possible premature convergence and evolutionary factors, the authors introduce the current (endoscopic camera and electromagnetic sensor’s) observation to boost the particle swarm optimization and also adaptively update evolutionary parameters in accordance with spatial constraints and the current observation, resulting in advantageous performance in the enhanced algorithm. Results: The experimental results demonstrate that the authors’ proposed method provides a more accurate and robust endoscopic guidance framework than state-of-the-art methods. The average guidance accuracy of the authors’ framework was about 3.0 mm and 5.6° while the previous methods show at least 3.9 mm and 7.0°. The average position and orientation smoothness of their method was 1.0 mm and 1.6°, which is significantly better than the other methods at least with (2.0 mm and 2.6°). Additionally, the average visual quality of the endoscopic guidance was improved to 0.29. Conclusions: A robust electromagnetically guided endoscopy framework was

  10. Robust electromagnetically guided endoscopic procedure using enhanced particle swarm optimization for multimodal information fusion.

    Science.gov (United States)

    Luo, Xiongbiao; Wan, Ying; He, Xiangjian

    2015-04-01

    Electromagnetically guided endoscopic procedure, which aims at accurately and robustly localizing the endoscope, involves multimodal sensory information during interventions. However, it still remains challenging in how to integrate these information for precise and stable endoscopic guidance. To tackle such a challenge, this paper proposes a new framework on the basis of an enhanced particle swarm optimization method to effectively fuse these information for accurate and continuous endoscope localization. The authors use the particle swarm optimization method, which is one of stochastic evolutionary computation algorithms, to effectively fuse the multimodal information including preoperative information (i.e., computed tomography images) as a frame of reference, endoscopic camera videos, and positional sensor measurements (i.e., electromagnetic sensor outputs). Since the evolutionary computation method usually limits its possible premature convergence and evolutionary factors, the authors introduce the current (endoscopic camera and electromagnetic sensor's) observation to boost the particle swarm optimization and also adaptively update evolutionary parameters in accordance with spatial constraints and the current observation, resulting in advantageous performance in the enhanced algorithm. The experimental results demonstrate that the authors' proposed method provides a more accurate and robust endoscopic guidance framework than state-of-the-art methods. The average guidance accuracy of the authors' framework was about 3.0 mm and 5.6° while the previous methods show at least 3.9 mm and 7.0°. The average position and orientation smoothness of their method was 1.0 mm and 1.6°, which is significantly better than the other methods at least with (2.0 mm and 2.6°). Additionally, the average visual quality of the endoscopic guidance was improved to 0.29. A robust electromagnetically guided endoscopy framework was proposed on the basis of an enhanced particle swarm

  11. Robust electromagnetically guided endoscopic procedure using enhanced particle swarm optimization for multimodal information fusion

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Xiongbiao, E-mail: xluo@robarts.ca, E-mail: Ying.Wan@student.uts.edu.au [Robarts Research Institute, Western University, London, Ontario N6A 5K8 (Canada); Wan, Ying, E-mail: xluo@robarts.ca, E-mail: Ying.Wan@student.uts.edu.au; He, Xiangjian [School of Computing and Communications, University of Technology, Sydney, New South Wales 2007 (Australia)

    2015-04-15

    Purpose: Electromagnetically guided endoscopic procedure, which aims at accurately and robustly localizing the endoscope, involves multimodal sensory information during interventions. However, it still remains challenging in how to integrate these information for precise and stable endoscopic guidance. To tackle such a challenge, this paper proposes a new framework on the basis of an enhanced particle swarm optimization method to effectively fuse these information for accurate and continuous endoscope localization. Methods: The authors use the particle swarm optimization method, which is one of stochastic evolutionary computation algorithms, to effectively fuse the multimodal information including preoperative information (i.e., computed tomography images) as a frame of reference, endoscopic camera videos, and positional sensor measurements (i.e., electromagnetic sensor outputs). Since the evolutionary computation method usually limits its possible premature convergence and evolutionary factors, the authors introduce the current (endoscopic camera and electromagnetic sensor’s) observation to boost the particle swarm optimization and also adaptively update evolutionary parameters in accordance with spatial constraints and the current observation, resulting in advantageous performance in the enhanced algorithm. Results: The experimental results demonstrate that the authors’ proposed method provides a more accurate and robust endoscopic guidance framework than state-of-the-art methods. The average guidance accuracy of the authors’ framework was about 3.0 mm and 5.6° while the previous methods show at least 3.9 mm and 7.0°. The average position and orientation smoothness of their method was 1.0 mm and 1.6°, which is significantly better than the other methods at least with (2.0 mm and 2.6°). Additionally, the average visual quality of the endoscopic guidance was improved to 0.29. Conclusions: A robust electromagnetically guided endoscopy framework was

  12. Combined ultrasound and MR imaging to guide focused ultrasound therapies in the brain

    Science.gov (United States)

    Arvanitis, Costas D.; Livingstone, Margaret S.; McDannold, Nathan

    2013-07-01

    Several emerging therapies with potential for use in the brain, harness effects produced by acoustic cavitation—the interaction between ultrasound and microbubbles either generated during sonication or introduced into the vasculature. Systems developed for transcranial MRI-guided focused ultrasound (MRgFUS) thermal ablation can enable their clinical translation, but methods for real-time monitoring and control are currently lacking. Acoustic emissions produced during sonication can provide information about the location, strength and type of the microbubble oscillations within the ultrasound field, and they can be mapped in real-time using passive imaging approaches. Here, we tested whether such mapping can be achieved transcranially within a clinical brain MRgFUS system. We integrated an ultrasound imaging array into the hemisphere transducer of the MRgFUS device. Passive cavitation maps were obtained during sonications combined with a circulating microbubble agent at 20 targets in the cingulate cortex in three macaques. The maps were compared with MRI-evident tissue effects. The system successfully mapped microbubble activity during both stable and inertial cavitation, which was correlated with MRI-evident transient blood-brain barrier disruption and vascular damage, respectively. The location of this activity was coincident with the resulting tissue changes within the expected resolution limits of the system. While preliminary, these data clearly demonstrate, for the first time, that it is possible to construct maps of stable and inertial cavitation transcranially, in a large animal model, and under clinically relevant conditions. Further, these results suggest that this hybrid ultrasound/MRI approach can provide comprehensive guidance for targeted drug delivery via blood-brain barrier disruption and other emerging ultrasound treatments, facilitating their clinical translation. We anticipate that it will also prove to be an important research tool that will

  13. Combined ultrasound and MR imaging to guide focused ultrasound therapies in the brain

    International Nuclear Information System (INIS)

    Arvanitis, Costas D; McDannold, Nathan; Livingstone, Margaret S

    2013-01-01

    Several emerging therapies with potential for use in the brain, harness effects produced by acoustic cavitation—the interaction between ultrasound and microbubbles either generated during sonication or introduced into the vasculature. Systems developed for transcranial MRI-guided focused ultrasound (MRgFUS) thermal ablation can enable their clinical translation, but methods for real-time monitoring and control are currently lacking. Acoustic emissions produced during sonication can provide information about the location, strength and type of the microbubble oscillations within the ultrasound field, and they can be mapped in real-time using passive imaging approaches. Here, we tested whether such mapping can be achieved transcranially within a clinical brain MRgFUS system. We integrated an ultrasound imaging array into the hemisphere transducer of the MRgFUS device. Passive cavitation maps were obtained during sonications combined with a circulating microbubble agent at 20 targets in the cingulate cortex in three macaques. The maps were compared with MRI-evident tissue effects. The system successfully mapped microbubble activity during both stable and inertial cavitation, which was correlated with MRI-evident transient blood–brain barrier disruption and vascular damage, respectively. The location of this activity was coincident with the resulting tissue changes within the expected resolution limits of the system. While preliminary, these data clearly demonstrate, for the first time, that it is possible to construct maps of stable and inertial cavitation transcranially, in a large animal model, and under clinically relevant conditions. Further, these results suggest that this hybrid ultrasound/MRI approach can provide comprehensive guidance for targeted drug delivery via blood–brain barrier disruption and other emerging ultrasound treatments, facilitating their clinical translation. We anticipate that it will also prove to be an important research tool that

  14. EFSUMB Guidelines on Interventional Ultrasound (INVUS), Part v

    DEFF Research Database (Denmark)

    Fusaroli, P; Jenssen, C.; Hocke, Martine

    2016-01-01

    The fifth section of the Guidelines on Interventional Ultrasound (INVUS) of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) assesses the evidence for all the categories of endoscopic ultrasound-guided treatment reported to date. Celiac plexus neurolysis and bl...

  15. Preoperative ultrasound measurements predict the feasibility of gallbladder extraction during transgastric natural orifice translumenal endoscopic surgery cholecystectomy.

    Science.gov (United States)

    Santos, Byron F; Auyang, Edward D; Hungness, Eric S; Desai, Kush R; Chan, Edward S; van Beek, Darren B; Wang, Edward C; Soper, Nathaniel J

    2011-04-01

    Extraction of a gallbladder through an endoscopic overtube during natural orifice translumenal endoscopic surgery (NOTES) transgastric cholecystectomy avoids potential injury to the esophagus. This study examined the rate of successful gallbladder specimen extraction through an overtube and hypothesized that preoperative ultrasound findings could predict successful specimen passage. Gallbladder specimens from patients undergoing laparoscopic cholecystectomy were measured, and an attempt was made to pull the specimens through a commercially available overtube with an inner diameter of 16.7-mm. A radiologist blinded to the outcomes reviewed the available preoperative ultrasound measurements from these patients. Ultrasound dimensions including gallbladder length, width, and depth; wall thickness; common bile duct diameter; and size of the largest gallstone (LGS) were recorded. Multiple logistic regression analysis was performed to determine whether ultrasound findings and patient characteristics (age, body mass index [BMI], and sex) could predict the ability of a specimen to pass through the overtube. Of 57 patients, 44 (77%) who had preoperative ultrasounds available for electronic review were included in the final analysis. Gallstones were present in 35 (79%) of these 44 patients. Intraoperative gallbladder perforation occurred in 18 (41%) of the 44 patients, and 16 (36%) of the 44 gallbladders could be extracted through the overtube. Measurement of LGS was possible for 23 patients, and indeterminate gallstone size (IGS) was determined for 12 patients. The rate for passage of perforated versus intact gallbladders was similar (40% vs. 23%; p = 0.054). The LGS (odds ratio [OR], 1.17; 95% confidence interval [CI], 1.02-1.33; p = 0.021) and IGS (OR, 22.97; 95% CI, 1.99-265.63; p = 0.025) predicted failed passage on multivariate logistic regression analysis. The passage rate was 80% for LGS smaller than 10 mm or no stones present, 18% for LGS 10 mm or larger, and 8% for

  16. Development of EndoTOFPET-US, a multi-modal endoscope for ultrasound and time of flight positron emission tomography

    International Nuclear Information System (INIS)

    Pizzichemi, M

    2014-01-01

    The EndoTOFPET-US project aims at delevoping a multi-modal imaging device that combines Ultrasound with Time-Of-Flight Positron Emission Tomography into an endoscopic imaging device. The goal is to obtain a coincidence time resolution of about 200 ps FWHM and sub-millimetric spatial resolution for the PET head, integrating the components in a very compact detector suitable for endoscopic use. The scanner will be exploited for the clinical test of new bio-markers especially targeted for prostate and pancreatic cancer as well as for diagnostic and surgical oncology. This paper focuses on the status of the Time-Of-Flight Positron Emission Tomograph under development for the EndoTOFPET-US project

  17. Models to teach lung sonopathology and ultrasound-guided thoracentesis

    Directory of Open Access Journals (Sweden)

    Jacek A. Wojtczak

    2014-12-01

    Full Text Available Lung sonography allows rapid diagnosis of lung emergencies such as pulmonary edema, hemothorax or pneumothorax. The ability to timely diagnose an intraoperative pneumothorax is an important skill for the anesthesiologist. However, lung ultrasound exams require an interpretation of not only real images but also complex acoustic artifacts such as A-lines and B-lines. Therefore, appropriate training to gain proficiency is important. Simulated environment using ultrasound phantom models allows controlled, supervised learning. We have developed hybrid models that combine dry or wet polyurethane foams, porcine rib cages and human hand simulating a rib cage. These models simulate fairly accurately pulmonary sonopathology and allow supervised teaching of lung sonography with the immediate feedback. In-vitro models can also facilitate learning of procedural skills, improving transducer and needle positioning and movement, rapid recognition of thoracic anatomy and hand – eye coordination skills. We described a new model to teach an ultrasound guided thoracentesis. This model consists of the experimenter’s hand placed on top of the water-filled container with a wet foam. Metacarpal bones of the human hand simulate a rib cage and a wet foam simulates a diseased lung immersed in the pleural fluid. Positive fluid flow offers users feedback when a simulated pleural effusion is accurately assessed.

  18. Endoscopic Ultrasound in Endocrinology: Imaging of the Adrenals and the Endocrine Pancreas.

    Science.gov (United States)

    Kann, Peter Herbert

    2016-01-01

    Endoscopic ultrasound (EUS) imaging of adrenal glands and its application to diagnostic procedures of adrenal diseases has been reported since 1998. It can be considered a relevant advantage in the field of adrenal diseases. Indeed, EUS allows the detection of adrenal lesions (even very small ones) and their characterization, the assessment of malignancy criteria, the early detection of neoplastic recurrences, the preoperative identification of morphologically healthy parts of the glands, the differentiation of extra-adrenal from adrenal tumors, and of the pathological entities associated with adrenal insufficiency, and the fine-needle aspiration biopsy (EUS-FNA) of suspicious lesions. At the same time, its clinical relevance depends on the experience of the endosonographer. Moreover, EUS is also by far the best and most sensitive imaging technique to detect and assess the follow-up of pancreatic manifestation of MEN1 disease. It furthermore enables the preoperatively localization of insulinomas and critical structures in their neighborhood, and may be relevant in planning surgical strategy. A positive EUS in a case of insulinoma furthermore confirms the endocrine diagnosis, especially considering the differential diagnosis of hypoglycemia factitia by oral antidiabetics. It can be supplemented by EUS-FNA. Again, it has to be considered that EUS may reveal false positive and false negative results, and the quality of the findings largely depends on the endosonographer's skills and experience. The most important technical details together with the advantages and limitations of EUS, and the pathognomonic characteristic of benign and malignant disorders of the adrenals and pancreas are presented here. © 2016 S. Karger AG, Basel.

  19. Ultrasound-guided high-intensity focused ultrasound treatment for abdominal wall endometriosis: Preliminary results

    International Nuclear Information System (INIS)

    Wang Yang; Wang Wei; Wang Longxia; Wang Junyan; Tang Jie

    2011-01-01

    Purpose: To evaluate the safety and therapeutic efficacy of ultrasound (US)-guided high-intensity focused ultrasound (HIFU) ablation for the treatment of abdominal wall endometriosis (AWE). Materials and methods: Twenty-one consecutive patients with AWE were treated as outpatients by US-guided HIFU ablation under conscious sedation. The median size of the AWE was 2.4 cm (range 1.0-5.3 cm). An acoustic power of 200-420 W was used, intermittent HIFU exposure of 1 s was applied. Treatment was considered complete when the entire nodule and its nearby 1 cm margin become hyperechoic on US. Pain relief after HIFU ablation was observed and the treated nodule received serial US examinations during follow-up. Results: All AWE was successfully ablated after one session of HIFU ablation, the ablation time lasted for 5-48 min (median 13 min), no major complications occurred. The cyclic pain disappeared in all patients during a mean follow-up of 18.7 months (range 3-31 months). The treated nodules gradually shank over time, 16 nodules became unnoticeable on US during follow-up. Conclusion: US-guided HIFU ablation appears to be safe and effective for the treatment of AWE.

  20. Ultrasound-guided high-intensity focused ultrasound treatment for abdominal wall endometriosis: Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Wang Yang [Department of Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing 100853 (China); Wang Wei, E-mail: wangyang301301@yahoo.com.cn [Department of Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing 100853 (China); Wang Longxia; Wang Junyan; Tang Jie [Department of Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing 100853 (China)

    2011-07-15

    Purpose: To evaluate the safety and therapeutic efficacy of ultrasound (US)-guided high-intensity focused ultrasound (HIFU) ablation for the treatment of abdominal wall endometriosis (AWE). Materials and methods: Twenty-one consecutive patients with AWE were treated as outpatients by US-guided HIFU ablation under conscious sedation. The median size of the AWE was 2.4 cm (range 1.0-5.3 cm). An acoustic power of 200-420 W was used, intermittent HIFU exposure of 1 s was applied. Treatment was considered complete when the entire nodule and its nearby 1 cm margin become hyperechoic on US. Pain relief after HIFU ablation was observed and the treated nodule received serial US examinations during follow-up. Results: All AWE was successfully ablated after one session of HIFU ablation, the ablation time lasted for 5-48 min (median 13 min), no major complications occurred. The cyclic pain disappeared in all patients during a mean follow-up of 18.7 months (range 3-31 months). The treated nodules gradually shank over time, 16 nodules became unnoticeable on US during follow-up. Conclusion: US-guided HIFU ablation appears to be safe and effective for the treatment of AWE.

  1. Gelatin model for training ultrasound-guided puncture

    Directory of Open Access Journals (Sweden)

    Alexandre Campos Moraes Amato

    2015-09-01

    Full Text Available BACKGROUND: It is indispensable that members of the medical profession receive the technical training needed to enable them to rapidly obtain effective vascular access. Training procedures should be used judiciously to familiarize students with the technique. However, existing models are expensive or ineffective, and models need to be developed that are similar to what will be encountered in real patients.OBJECTIVES: To demonstrate creation and application of a gelatin model for training ultrasound-guided puncture.METHOS: The model was made using a mixture of colorless gelatin and water in a transparent plastic receptacle with two pairs of orifices of different diameters, through which two plastic tubes were inserted, to simulate blood vessels.RESULTS: The model was a close approximation to the real medical procedure in several aspects, since gelatin has a similar consistency to human tissues, providing a more faithful reproduction of the tactile sensation at the moment when the needle reaches the interior of a vessel and its contents are aspirated.CONCLUSIONS: The method proposed here can be used to easily construct a low-cost model using everyday materials that is suitable for large-scale training of ultrasound-guided puncture.

  2. Microwave ablation of liver metastases guided by contrast-enhanced ultrasound

    DEFF Research Database (Denmark)

    Lorentzen, T; Skjoldbye, B O; Nolsoe, C P

    2011-01-01

    The aim of our study was to evaluate the efficacy of microwave (MW) ablation of liver metastases guided by B-mode ultrasound (US) and contrast-enhanced US (CEUS).......The aim of our study was to evaluate the efficacy of microwave (MW) ablation of liver metastases guided by B-mode ultrasound (US) and contrast-enhanced US (CEUS)....

  3. Ultrasound-guided drainage of subcutaneous abscesses on the trunk is feasible

    DEFF Research Database (Denmark)

    Kjær, Søren; Rud, Bo; Bay-Nielsen, Morten

    2013-01-01

    Subcutaneous trunk abscesses are frequent, and current treatment options generally involve incision. By contrast, the standard care for breast abcesses is ultrasound-guided drainage. The aim of this study was to evaluate the feasibility of ultrasound-guided drainage combined with antibiotics...... in the treatment of subcutaneous abscesses on the trunk....

  4. Technical tips to perform safe and effective ultrasound guided steroid joint injections in children.

    Science.gov (United States)

    Parra, Dimitri A

    2015-01-01

    The aim of this article is to describe the technique used to perform ultrasound guided steroid joint injections in children in a group of joints that can be injected using ultrasound as the only image guidance modality. The technique is described and didactic figures are provided to illustrate key technical concepts. It is very important to be familiar with the sonographic appearance of the pediatric joints and the developing bone when performing ultrasound-guided joint injections in children.

  5. Transvaginal Ultrasound-Guided Biopsy of Deep Pelvic Masses: How We Do It.

    Science.gov (United States)

    Plett, Sara K; Poder, Liina; Brooks, Rebecca A; Morgan, Tara A

    2016-06-01

    The purpose of this review is to discuss the rationale and indications for transvaginal ultrasound-guided biopsy. Transvaginal ultrasound-guided biopsy can be a helpful tool for diagnosis and treatment planning in the evaluation of pelvic masses, particularly when the anatomy precludes a transabdominal or posterior transgluteal percutaneous biopsy approach. A step-by-step summary of the technique with preprocedure and postprocedure considerations is included. © 2016 by the American Institute of Ultrasound in Medicine.

  6. Ultrasound guided core biopsy of suspicious mammographic calcifications using high frequency and power Doppler ultrasound

    International Nuclear Information System (INIS)

    Teh, W.L.; Wilson, A.R.M; Evans, A.J.; Burrell, H.; Pinder, S.E.; Ellis, I.O.

    2000-01-01

    AIM: The pre-operative diagnosis of suspicious mammographic microcalcifications usually requires stereotactic needle biopsy. The aim of this study was to evaluate if high frequency 13 MHz ultrasound (HFUS) and power Doppler (PD) can aid visualization and biopsy of microcalcifications. MATERIALS AND METHODS: Forty-four consecutive patients presenting with microcalcifications without associated mammographic or palpable masses were examined with HFUS and PD. Ultrasound-guided core biopsy (USCB) was performed where possible. Stereotactic biopsy was carried out when US-guided biopsy was unsuccessful. Surgery was performed if a diagnosis of malignancy was made on core biopsy or if the repeat core biopsy was non-diagnostic. RESULTS: Forty-one patients (93%) had ultrasound abnormalities corresponding to mammographic calcification. USCB was performed on 37 patients. In 29/37, USCB obtained a definitive result (78.4%). USCB was non-diagnostic in 4/9 benign (44.4%) and 4/28 (14.3%) malignant lesions biopsied. The complete and absolute sensitivities for malignancy using USCB were 85.7% (24/28) and 81% (23/28), respectively. USCB correctly identified invasive disease in 12/23 (52.2%) cases. There was no significant difference in the presence of abnormal flow on PD between benign and malignant lesions. However, abnormal PD vascularity was present in 43.5% of invasive cancer and was useful in directing successful biopsy in eight cases. CONCLUSION: The combination of high frequency US with PD is useful in the detection and guidance of successful needle biopsy of microcalcifications particularly where there is an invasive focus within larger areas of DCIS. Teh, W.L. (2000)

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound or with a rectal examination, an ultrasound-guided biopsy can be performed. This procedure involves advancing ... of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate Sponsored ...

  8. Evaluation of ultrasound-guided vascular access in dogs.

    Science.gov (United States)

    Chamberlin, Scott C; Sullivan, Lauren A; Morley, Paul S; Boscan, Pedro

    2013-01-01

    To describe the technique and determine the feasibility, success rate, perceived difficulty, and time to vascular access using ultrasound guidance for jugular vein catheterization in a cardiac arrest dog model. Prospective descriptive study. University teaching hospital. Nine Walker hounds. A total of 27 jugular catheterizations were performed postcardiac arrest using ultrasound guidance. Catheterizations were recorded based on the order in which they were performed and presence/absence of a hematoma around the vein. Time (minutes) until successful vascular access and perceived difficulty in achieving vascular access (scale of 1 = easy to 10 = difficult) were recorded for each catheterization. Mean time to vascular access was 1.9 minutes (95% confidence interval, 1.1-3.4 min) for catheterizations without hematoma, versus 4.3 minutes (1.8-10.1 min) for catheterizations with hematoma (P = 0.1). Median perceived difficulty was 2 of 10 (range 1-7) for catheterizations without hematoma, versus 2 of 10 (range 1-8) for catheterizations with hematoma (P = 0.3). A learning curve was evaluated by comparing mean time to vascular access and perceived difficulty in initial versus subsequent catheterizations. Mean time to vascular access was 2.5 minutes (1.0-6.4 min) in the initial 13 catheterizations versus 3.3 minutes (1.5-7.5 min) in the subsequent 14 catheterizations (P = 0.6). Median perceived difficulty in the first 13 catheterizations (3, range 1-8) was significantly greater (P = 0.049) than median perceived difficulty in the subsequent 14 catheterizations (2, range 1-6). Ultrasound-guided jugular catheterization is associated with a learning curve but is successful in obtaining rapid vascular access in dogs. Further prospective studies are warranted to confirm the utility of this technique in a clinical setting. © Veterinary Emergency and Critical Care Society 2013.

  9. MR-guided focused ultrasound: a potentially disruptive technology.

    Science.gov (United States)

    Bradley, William G

    2009-07-01

    A disruptive technology is a technological innovation that overturns the existing dominant technologies in a market. Magnetic resonance (MR)-guided focused ultrasound (MRgFUS) is a noninvasive procedure based on the combination of real-time MR anatomic guidance, MR thermometry, and high-intensity focused ultrasound. Several hundred transducer elements become convergent at a point under MR guidance, leading to heating and coagulation necrosis. Outside the focal point, there is no significant heating. There is no need to break the skin for procedures in the body or to perform a craniotomy for procedures in the brain. This lack of invasiveness is what makes MRgFUS so disruptive compared with surgery. At present, MRgFUS has been used for the ablation of uterine fibroids, breast tumors, painful bony metastases, and liver tumors. In the brain, it has been used for the ablation of glioblastomas and for functional neurosurgery. Phantom and animal studies suggest future applications for prostate cancer and acute stroke treatment.

  10. Ultrasound guided percutaneous cholecystostomy in high-risk patients for surgical intervention.

    Science.gov (United States)

    Bakkaloglu, Huseyin; Yanar, Hakan; Guloglu, Recep; Taviloglu, Korhan; Tunca, Fatih; Aksoy, Murat; Ertekin, Cemalettin; Poyanli, Arzu

    2006-11-28

    To assess the efficacy and safety of ultrasound guided percutaneous cholecystostomy (PC) in the treatment of acute cholecystitis in a well-defined high risk patients under general anesthesia. The data of 27 consecutive patients who underwent percutaneous transhepatic cholecystostomy for the management of acute cholecystitis from January 1999 to June 2003 was retrospectively evaluated. All of the patients had both clinical and sonographic signs of acute cholecystitis and had comorbid diseases. Ultrasound revealed gallbladder stones in 25 patients and acalculous cholecystitis in two patients. Cholecystostomy catheters were removed 14-32 d (mean 23 d) after the procedure in cases where complete regression of all symptoms was achieved. There were statistically significant reductions in leukocytosis, (13.7 x 10(3)+/-1.3 x 10(3) microg/L vs 13 x 10(3)+/-1 x 10(3) microg/L, P extraction was performed successfully with endoscopic retrograde cholangio-pancreatography (ERCP) in three patients. After cholecystostomy, 5 (18%) patients underwent delayed cholecystectomy without any complications. Three out of 22 patients were admitted with recurrent acute cholecystitis during the follow-up and recovered with medical treatment. Catheter dislodgement occurred in three patients spontaneously, and two of them were managed by reinsertion of the catheter. As an alternative to surgery, percutaneous cholecystostomy seems to be a safe method in critically ill patients with acute cholecystitis and can be performed with low mortality and morbidity. Delayed cholecystectomy and ERCP, if needed, can be performed after the acute period has been resolved by percutaneous cholecystostomy.

  11. Laparoscopic Ultrasound-Guided Radiofrequency Ablation of Uterine Fibroids

    International Nuclear Information System (INIS)

    Milic, Andrea; Asch, Murray R.; Hawrylyshyn, Peter A.; Allen, Lisa M.; Colgan, Terence J.; Kachura, John R.; Hayeems, Eran B.

    2006-01-01

    Four patients with symptomatic uterine fibroids measuring less than 6 cm underwent laparoscopic ultrasound-guided radiofrequency ablation (RFA) using multiprobe-array electrodes. Follow-up of the treated fibroids was performed with gadolinium-enhanced magnetic resonance imaging (MRI) and patients' symptoms were assessed by telephone interviews. The procedure was initially technically successful in 3 of the 4 patients and MRI studies at 1 month demonstrated complete fibroid ablation. Symptom improvement, including a decrease in menstrual bleeding and pain, was achieved in 2 patients at 3 months. At 7 months, 1 of these 2 patients experienced symptom worsening which correlated with recurrent fibroid on MRI. The third, initially technically successfully treated patient did not experience any symptom relief after the procedure and was ultimately diagnosed with adenomyosis. Our preliminary results suggest that RFA is a technically feasible treatment for symptomatic uterine fibroids in appropriately selected patients

  12. Ultrasound guided transrectal catheter drainage of pelvic collections.

    Science.gov (United States)

    Thakral, Anuj; Sundareyan, Ramaniwas; Kumar, Sheo; Arora, Divya

    2015-01-01

    The transrectal approach to draining deep-seated pelvic collections may be used to drain The transrectal approach to draining deep-seated pelvic collections may be used to drain intra-abdominal collections not reached by the transabdominal approach. We discuss 6 patients with such pelvic collections treated with transrectal drainage using catheter placement via Seldinger technique. Transrectal drainage helped achieve clinical and radiological resolution of pelvic collections in 6 and 5 of 6 cases, respectively. It simultaneously helped avoid injury to intervening bowel loops and neurovascular structures using real-time visualization of armamentarium used for drainage. Radiation exposure from fluoroscopic/CT guidance was avoided. Morbidity and costs incurred in surgical exploration were reduced using this much less invasive ultrasound guided transrectal catheter drainage of deep-seated pelvic collections.

  13. Ultrasound-guided block of the axillary nerve

    DEFF Research Database (Denmark)

    Rothe, C; Lund, J; Jenstrup, M T

    2012-01-01

    The specific blocking of the axillary nerve has never been investigated clinically. We present four cases illustrating potential applications of the axillary nerve block in the perioperative setting and discuss possible directions for future research in this area. The axillary nerve blocks were all...... performed using a newly developed in-plane ultrasound-guided technique. In one patient undergoing arthroscopic shoulder surgery, we used the axillary nerve block as the only analgesic combined with propofol sedation and spontaneous breathing. Chronic shoulder pain was eliminated after the axillary nerve...... block in two patients. The pain score after arthroscopic shoulder surgery in these two patients remained low until termination of the nerve block. In a fourth patient, severe post-operative pain after osteosynthesis of a displaced proximal humerus fracture was almost eliminated after performing...

  14. Inexpensive homemade models for ultrasound-guided vein cannulation training.

    Science.gov (United States)

    Di Domenico, Stefano; Santori, Gregorio; Porcile, Elisa; Licausi, Martina; Centanaro, Monica; Valente, Umberto

    2007-11-01

    To test the hypothesis that low-cost homemade models may be used to acquire the basic skills for ultrasound-guided central vein puncture. Training study. University transplantation department. Training was performed using three different homemade models (A, B, and C). Segments of a common rubber tourniquet (V1) and Silastic tube (V2) were used to simulate vessels within agar-based models. Overall cost for each model was less than 5 euro (US$7). For each test (test I, A-V1; II, A-V2; III, B-V1; IV, C-V2), the number of punctures and attempts needed to locate the needle inside the lumen were recorded. Each test was considered completed when participants punctured the vessels at the first attempt for three consecutive times. In test I, the mean number of punctures and attempts were 3.85 +/- 1.26 and 4.95 +/- 3.05; in test II, 4.60 +/- 1.14 and 6.30 +/- 2.51; in test III, 4.80 +/- 1.06 and 4.65 +/- 2.21; and in test IV, 4.45 +/- 1.23 and 6.05 +/- 2.92, respectively. For each test, no statistical difference was found by comparison of number of punctures and attempts for anesthesiologists versus nonanesthesiologists, men versus women, or previous experience versus no experience with central vein cannulation (CVC). Video game users obtained better results than did nonusers in test I (punctures, P = 0.033; attempts, P = 0.038), test II (punctures, P = 0.052; attempts, P = 0.011), and test IV (punctures, P = 0.001; attempts, P = 0.003). A posttraining questionnaire showed favorable opinions about the clarity of the instructions, aptness of the models, and adequacy of the training. In our operative unit, the use of ultrasound guidance for CVC increased from 2% to 23% in the first month after training. Low-cost homemade models are useful in acquiring basic coordination skills for ultrasound-guided CVC.

  15. Interactive navigation-guided ophthalmic plastic surgery: navigation enabling of telescopes and their use in endoscopic lacrimal surgeries

    Directory of Open Access Journals (Sweden)

    Ali MJ

    2016-11-01

    Full Text Available Mohammad Javed Ali,1 Swati Singh,1 Milind N Naik,1 Swathi Kaliki,2 Tarjani Vivek Dave1 1The Institute of Dacryology, 2The Operation Eyesight Universal Institute for Eye Cancer, L.V. Prasad Eye Institute, Hyderabad, India Purpose: The aims of this study were to report the preliminary experience of using telescopes, which were enabled for navigation guidance, and their utility in complex endoscopic lacrimal surgeries. Methods: Navigation enabling of the telescope was achieved by using the AxiEM™ malleable neuronavigation shunt stylet. Image-guided dacryolocalization was performed in five patients using the intraoperative image-guided StealthStation™ system in the electromagnetic mode. The “look ahead” protocol software was used to assist the surgeon in assessing the intraoperative geometric location of the endoscope and what lies ahead in real time. All patients underwent navigation-guided powered endoscopic dacryocystorhinostomy. The utility of uninterrupted navigation guidance throughout the surgery with the endoscope as the navigating tool was noted. Results: Intraoperative geometric localization of the lacrimal sac and the nasolacrimal duct could be easily deciphered. Constant orientation of the lacrimal drainage system and the peri-lacrimal anatomy was possible without the need for repeated point localizations throughout the surgery. The “look ahead” features could accurately alert the surgeon of anatomical structures that exists at 5, 10 and 15 mm in front of the endoscope. Good securing of the shunt stylet with the telescope was found to be essential for constant and accurate navigation. Conclusion: Navigation-enabled endoscopes provide the surgeon with the advantage of sustained stereotactic anatomical awareness at all times during the surgery. Keywords: telescope, endoscope, image guidance, navigation, lacrimal surgery, powered endoscopic DCR

  16. Ultrasound guided versus landmark guided corticosteroid injection in patients with rotator cuff syndrome: Randomised controlled trial.

    Science.gov (United States)

    Bhayana, Himanshu; Mishra, Puneet; Tandon, Anupama; Pankaj, Amite; Pandey, Rohit; Malhotra, Raskesh

    2018-03-01

    Impingement syndrome is the most common differential in a patient presenting to an orthopaedic OPD with shoulder pain. Impingement syndrome is often managed with subacromial corticosteroid injection, which can be instilled using either landmark guided (LMG) approach or with the assistance of ultrasound (US). This study was envisaged to enquire whether ultrasound assistance improves the accuracy, efficacy or safety profile of the injection. 60 patients of rotator cuff syndrome underwent diagnostic ultrasound. They were randomly assigned to receive subacromial injection of 2 ml (40 mg/ml) methylprenisolone and 2 ml of 1% lignocaine combination either by US assistance (n = 30) or using LMG assistance (n = 30). The patients were evaluated before injection and on follow up visits at day 5, week 3, week 6 and 3rd month by a single assessor. The assessor was blinded of the treatment group to which patient belonged. Clinical assessment included demographic and clinical data, accuracy of injection, VAS (0-100) for pain, Constant score with goniometer evaluation of range of motion, patient's self assessment proforma and post injection side effects if any. Initial demographic, clinical and US findings in the groups exhibited no significant differences. The accuracy of US guided injections (100%) was more when compared from LMG injection (93.3%). Both VAS and Constant score showed significant improvement following steroid injection up to 3 months of follow up. However the differences in the two groups were not significant suggesting comparable efficacy of the two approaches. (Mean VAS score decrease: 27.23 for US and 25.16 for LMG, p guided injections have a higher accuracy of drug placement in the subacromial bursa, there is no difference in terms of clinical outcomes or safety profile of either of the method. Hence US guided injections seems to be unjustified, when compared to equally efficacious and cost effective LMG steroid injection.

  17. The endoscopic ultrasonography-guided rendezvous technique for biliary cannulation: a technical review.

    Science.gov (United States)

    Isayama, Hiroyuki; Nakai, Yousuke; Kawakubo, Kazumichi; Kawakami, Hiroshi; Itoi, Takao; Yamamoto, Natsuyo; Kogure, Hirofumi; Koike, Kazuhiko

    2013-04-01

    Steady progress is being made in endoscopic biliary intervention, especially endoscopic ultrasonography (EUS)-guided procedures. The EUS-guided rendezvous technique (EUS-RV) is a salvage method for failed selective biliary cannulation. The overall success rate of EUS-RV in 247 cases from seven published articles was 74 % and the incidence of complications was 11 %. The main cause of failed rendezvous cannulation was difficulty passing a biliary stricture or papilla due to poor guidewire (GW) manipulation. A recent large study found a 98.3 % success rate and superiority to precutting. This report suggested using a hydrophilic guidewire. Major complications were bleeding (0.8 %), bile leakage (1.2 %), peritonitis (0.4 %), pneumoperitoneum (0.2 %), and pancreatitis (1.6 %). The approach routes for EUS-RV were transgastric, transduodenal short position, and transduodenal long position. The appropriate route for each patient should be used. GW selection for EUS-RV is critical, and a hydrophilic GW might be the most useful. The catheter can be inserted through the papilla alongside or over the wire. Alongside cannulation is convenient, but difficult. The problem with the over-the-wire technique is withdrawal of the GW in the accessory channel. EUS-RV is effective and safe, but is not established. The efficacy should be confirmed in a prospective comparative trial, and the necessary specialist equipment should be developed.

  18. [Efficacy and safety of ultrasound-guided or neurostimulator-guided bilateral axillary brachial plexus block].

    Science.gov (United States)

    Xu, C S; Zhao, X L; Zhou, H B; Qu, Z J; Yang, Q G; Wang, H J; Wang, G

    2017-10-17

    Objective: To explore the efficacy and safety of bilateral axillary brachial plexus block under the guidance of ultrasound or neurostimulator. Methods: From February 2012 to April 2014, 120 patients undergoing bilateral hand/forearm surgery in Beijing Jishuitan Hospital were enrolled and anaesthetized with bilateral axillary brachial plexus block. All patients were divided into two groups randomly using random number table: the ultrasound-guided group (group U, n =60) and the neurostimulator-guidedgroup (group N, n =60). The block was performed with 0.5% ropivacaine. Patients' age, sex and operation duration were recorded. Moreover, success rate, performance time, onset of sensor and motor block, performance pain, patient satisfaction degree and the incidence of related complications were also documented. Venous samples were collected at selected time points and the total and the plasma concentrations of ropivacaine were analyzed with HPLC. Results: The performance time, the onset of sensor block and the onset of motor block of group U were (8.2±1.5), (14.2± 2.2)and (24.0±3.5)min respectively, which were markedly shorter than those in group N( (14.6±3.9), (19.9±3.8), (28.8±4.2)min, respectively), and the differences were statistically significant( t =11.74, 10.09, 6.73, respectively, all P 0.05). No analgesic was superadded and no other anesthesia methods were applied. No complications were detected perioperatively. Conclusions: The bilateral axillary brachial plexus block under the guidance of ultrasound or neurostimulator are both effective and safe for bilateral hand/forearm surgery. However, the ultrasound-guided block may be more clinically beneficial because of its shorter performance time, rapid onset and higher patient satisfaction degree.

  19. Endoscopic biopsy of foramen of Monro and third ventricle lesions guided by frameless neuronavigation: usefulness and limitations.

    Science.gov (United States)

    Prat, Ricardo; Galeano, Inmaculada

    2009-09-01

    To describe our institution experience regarding the usefulness and limitations of frameless neuronavigation in the endoscopic biopsy of foramen of Monro and third ventricle lesions. We report our experience with 22 patients harbouring intraventricular lesions located in the region of the foramen of Monro or the third ventricle who underwent endoscopic biopsy guided by the neuronavigation system. Nine lesions were located on the posterior aspect of the third ventricle or at the pineal region, and thirteen lesions were located at the foramen of Monro or anterior third ventricle region. The endoscopes were introduced via an operating sheath, which had previously been inserted with a trocar under neuronavigational control. After approaching the foramen of Monro from the planned angle, surgery was continued under direct visualisation until the lesion was reached, if it was located on the third ventricle. In cases where the lesion was located at the foramen of Monro, an excellent view of the lesion was obtained and neuronavigation was used to determine the location of critical areas. Histological examination of biopsy specimens obtained endoscopically was diagnostic in all cases. Open surgery following endoscopic biopsy was only needed in 1 patient out of 22. In our experience, image-guided neuroendoscopy can improve the accuracy of the endoscopic approach, minimising brain trauma. It can be particularly helpful when performing a brain biopsy in the absence of clear intraventricular landmarks or in the event of adverse visual conditions such as intraventricular bleeding.

  20. Ultrasound- versus palpation-guided injection of corticosteroid for plantar fasciitis: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Zonghuan Li

    Full Text Available It is controversial whether ultrasound-guided injection of corticosteroid is superior to palpation-guided injection for plantar fasciitis. This meta-analysis was performed to compare the effectiveness of ultrasound-guided and palpation-guided injection of corticosteroid for the treatment of plantar fasciitis.Databases (MEDLINE, Cochrane library and EMBASE and reference lists were searched from their establishment to August 30, 2013 for randomized controlled trials (RCTs comparing ultrasound-guided with palpation-guided injection for plantar fasciitis. The Cochrane risk of bias (ROB tool was used to assess the methodological quality. Outcome measurements were visual analogue scale (VAS, tenderness threshold (TT, heel tenderness index (HTI, response rate, plantar fascia thickness (PFT, hypoechogenicity and heel pad thickness (HPT. The statistical analysis was performed with software RevMan 5.2 and Stata 12.0. When I2<50%, the fixed-effects model was adopted. Otherwise the randomized-effects model was adopted. The Grading of Recommendations Assessment, Development and Evaluation (GRADE system was used to assess the quality of evidence.Five RCTs with 149 patients were identified and analyzed. Compared with palpation-guided injection, ultrasound-guided injection was superior with regard to VAS, TT, response rate, PFT and hypoechogenicity. However, there was no statistical significance between the two groups for HPT and HTI.Ultrasound-guided injection of corticosteroid tends to be more effective than palpation-guided injection. However, it needs to be confirmed by further research.

  1. Ultrasound- versus Palpation-Guided Injection of Corticosteroid for Plantar Fasciitis: A Meta-Analysis

    Science.gov (United States)

    Yu, Aixi; Qi, Baiwen

    2014-01-01

    Background It is controversial whether ultrasound-guided injection of corticosteroid is superior to palpation-guided injection for plantar fasciitis. This meta-analysis was performed to compare the effectiveness of ultrasound-guided and palpation-guided injection of corticosteroid for the treatment of plantar fasciitis. Methods Databases (MEDLINE, Cochrane library and EMBASE) and reference lists were searched from their establishment to August 30, 2013 for randomized controlled trials (RCTs) comparing ultrasound-guided with palpation-guided injection for plantar fasciitis. The Cochrane risk of bias (ROB) tool was used to assess the methodological quality. Outcome measurements were visual analogue scale (VAS), tenderness threshold (TT), heel tenderness index (HTI), response rate, plantar fascia thickness (PFT), hypoechogenicity and heel pad thickness (HPT). The statistical analysis was performed with software RevMan 5.2 and Stata 12.0. When I2<50%, the fixed-effects model was adopted. Otherwise the randomized-effects model was adopted. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was used to assess the quality of evidence. Results Five RCTs with 149 patients were identified and analyzed. Compared with palpation-guided injection, ultrasound-guided injection was superior with regard to VAS, TT, response rate, PFT and hypoechogenicity. However, there was no statistical significance between the two groups for HPT and HTI. Conclusion Ultrasound-guided injection of corticosteroid tends to be more effective than palpation-guided injection. However, it needs to be confirmed by further research. PMID:24658102

  2. Endoscopic ultrasound duplex scanning for measurement of portal venous flow. Validation against transit time ultrasound flowmetry in pigs

    DEFF Research Database (Denmark)

    Hansen, E F; Strandberg, C; Bendtsen, F

    1999-01-01

    with that of transit time ultrasound (TTU) in healthy pigs. The ability of EUS to detect changes in the portal venous flow after pharmacologic intervention was also investigated. METHODS: Six anaesthetized pigs were studied. Portal venous flow was measured simultaneously by EUS duplex scanning, using a Pentax FG-32UA...... echoendoscope connected to a Hitachi EUB 515-A ultrasound scanner, and by TTU with a Cardiomed CM 4000 flowmeter probe placed on the portal vein. Terlipressin, 1 mg, and placebo were administered in a blind, randomized, crossover design. Measurements were taken at base line and 30 min after each drug...

  3. Percutaneous ultrasound-guided renal biopsy: A Libyan experience

    Science.gov (United States)

    Mishra, A.; Tarsin, R.; ElHabbash, B.; Zagan, N.; Markus, R.; Drebeka, S.; AbdElmola, K.; Shawish, T.; Shebani, A.; AbdElmola, T.; ElUsta, A.; Ehtuish, E. F.

    2010-01-01

    This study was done to assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy (PRB), to ascertain the risk factors for complications and determine the optimal period of observation. The radiologist (A.M.) at the National Organ Transplant Centre, Central Hospital, Tripoli, Libya, performed 86 PRBs between February 1, 2006, and January 31, 2008, using an automated biopsy gun with 16-gauge needle. Coagulation profile was done in all the patients. All patients were kept on strict bed rest for six hours post-procedure. Eighty six renal biopsies were performed on 78 patients referred from rheumatology department and eight post-kidney transplant recipients; 23 were males with age range 15 – 56 years and 63 females with age range 16 – 66 years. A mean of 17.5 glomeruli were present in each specimen. A glomerular yield of less than five glomeruli was seen in four biopsies. Class I lupus nephritis (LN) was seen in 1 patient, class II lupus nephritis in 7 patients, class III LN in 13 patients and class IV LN in 29 patients. All the eight renal allografts were diagnosed as acute tubular necrosis or acute interstitial rejection. The risk of post-biopsy bleeding was higher in women, older patients and higher PTT. The overall complication rate was 5.8%. Three complications were observed within six hours of biopsy. No late complication was seen. PRB under real-time ultrasound-guidance is a safe and efficacious procedure to establish the histological diagnosis and should be done as out-patient procedure. Observation time of six hours post-biopsy is optimal. PMID:20835320

  4. Ultrasound-guided lumpectomy of nonpalpable breast cancer versus wire-guided resection: a randomized clinical trial.

    NARCIS (Netherlands)

    Rahusen, F.D.; Bremers, A.J.A.; Fabry, H.F.; Taets van Amerongen, A.H.; Boom, R.P.; Meijer, S.

    2002-01-01

    BACKGROUND: The wire-guided excision of nonpalpable breast cancer often results in tumor resections with inadequate margins. This prospective, randomized trial was undertaken to investigate whether intraoperative ultrasound (US) guidance enables a better margin clearance than the wire-guided

  5. A simple tissue model for practicing ultrasound guided vascular ...

    African Journals Online (AJOL)

    Introduction: The use of ultrasound in anaesthetic practice continues to be more established and the use of ultrasound guidance in establishing vascular access is recommended by various groups. We have developed a tissue model for the practice and skills development in ultrasound vascular access. Method: The tissue ...

  6. Image-guided focused ultrasound ablation of breast cancer: current status, challenges, and future directions

    NARCIS (Netherlands)

    Schmitz, A.C.; Gianfelice, D.; Daniel, B.L.; Mali, W.P.T.M.; Bosch, M.A.A.J. van den

    2008-01-01

    Image-guided focussed ultrasound (FUS) ablation is a noninvasive procedure that has been used for treatment of benign or malignant breast tumours. Image-guidance during ablation is achieved either by using real-time ultrasound (US) or magnetic resonance imaging (MRI). The past decade phase I

  7. Musculoskeletal ultrasound: how to treat calcific tendinitis of the rotator cuff by ultrasound-guided single-needle lavage technique.

    Science.gov (United States)

    Lee, Kenneth S; Rosas, Humberto G

    2010-09-01

    The purpose of this video article is to illustrate the ultrasound appearance of calcium deposition in the rotator cuff and provide a detailed step-by-step protocol for performing the ultrasound-guided single-needle lavage technique for the treatment of calcific tendinitis with emphasis on patient positioning, necessary supplies, real-time lavage technique, and steroid injection into the subacromial subdeltoid bursa. Musculoskeletal ultrasound is well established as a safe, cost-effective imaging tool in diagnosing and treating common musculoskeletal disorders. Calcific tendinitis of the rotator cuff is a common disabling cause of shoulder pain. Although most cases are self-limiting, a subset of patients is refractory to conservative therapy and requires treatment intervention. Ultrasound-guided lavage is an effective and safe minimally-invasive treatment not readily offered in the United States as an alternative to surgery, perhaps because of the limited prevalence of musculoskeletal ultrasound programs and limited training. On completion of this video article, the participant should be able to develop an appropriate diagnostic and therapeutic algorithm for the treatment of calcific tendinitis of the rotator cuff using ultrasound.

  8. Comparative study between ultrasound guided TAP block and paravertebral block in upper abdominal surgeries

    Directory of Open Access Journals (Sweden)

    Ruqaya M Elsayed Goda

    2017-01-01

    Conclusion: We concluded that ultrasound guided transverses abdominis plane block and thoracic paravertebral block were safe and effective anesthetic technique for upper abdominal surgery with longer and potent postoperative analgesia in thoracic paravertebral block than transverses abdominis block.

  9. Ultrasound-Guided Intervention for Treatment of Trigeminal Neuralgia: An Updated Review of Anatomy and Techniques

    Directory of Open Access Journals (Sweden)

    Abdallah El-Sayed Allam

    2018-01-01

    Full Text Available Orofacial myofascial pain is prevalent and most often results from entrapment of branches of the trigeminal nerves. It is challenging to inject branches of the trigeminal nerve, a large portion of which are shielded by the facial bones. Bony landmarks of the cranium serve as important guides for palpation-guided injections and can be delineated using ultrasound. Ultrasound also provides real-time images of the adjacent muscles and accompanying arteries and can be used to guide the needle to the target region. Most importantly, ultrasound guidance significantly reduces the risk of collateral injury to vital neurovascular structures. In this review, we aimed to summarize the regional anatomy and ultrasound-guided injection techniques for the trigeminal nerve and its branches, including the supraorbital, infraorbital, mental, auriculotemporal, maxillary, and mandibular nerves.

  10. Proactive error analysis of ultrasound-guided axillary brachial plexus block performance.

    LENUS (Irish Health Repository)

    O'Sullivan, Owen

    2012-07-13

    Detailed description of the tasks anesthetists undertake during the performance of a complex procedure, such as ultrasound-guided peripheral nerve blockade, allows elements that are vulnerable to human error to be identified. We have applied 3 task analysis tools to one such procedure, namely, ultrasound-guided axillary brachial plexus blockade, with the intention that the results may form a basis to enhance training and performance of the procedure.

  11. Size and Ultrasound Features Affecting Results of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    Science.gov (United States)

    Dong, YiJie; Mao, MinJing; Zhan, WeiWei; Zhou, JianQiao; Zhou, Wei; Yao, JieJie; Hu, YunYun; Wang, Yan; Ye, TingJun

    2017-11-09

    Our goal was to assess the diagnostic efficacy of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules according to size and US features. A retrospective correlation was made with 1745 whole thyroidectomy and hemithyroidectomy specimens with preoperative US-guided FNA results. All cases were divided into 5 groups according to nodule size (≤5, 5.1-10, 10.1-15, 15.1-20, and >20 mm). For target nodules, static images and cine clips of conventional US and color Doppler were obtained. Ultrasound images were reviewed and evaluated by two radiologists with at least 5 years US working experience without knowing the results of pathology, and then agreement was achieved. The Bethesda category I rate was higher in nodules larger than 15 mm (P 20 mm) with several US features tended to yield false-negative FNA results. © 2017 by the American Institute of Ultrasound in Medicine.

  12. MR-guided focused ultrasound surgery, present and future

    Energy Technology Data Exchange (ETDEWEB)

    Schlesinger, David, E-mail: djs9c@virginia.edu [Department of Radiation Oncology, University of Virginia, Charlottesville, Virginia 22908 and Department of Neurological Surgery, University of Virginia, Charlottesville, Virginia 22908 (United States); Benedict, Stanley [Department of Radiation Oncology, University of California Davis, Davis, California 95817 (United States); Diederich, Chris [Department of Radiation Oncology, University of California San Francisco, San Francisco, California 94115 (United States); Gedroyc, Wladyslaw [Department of Medicine, Imperial College, London SW7 2AZ (United Kingdom); Klibanov, Alexander [Departments of Medicine, Cardiovascular Medicine, and Biomedical Engineering, University of Virginia, Charlottesville, Virginia 22908 (United States); Larner, James [Department of Radiation Oncology, University of Virginia, Charlottesville, Virginia 22908 (United States)

    2013-08-01

    MR-guided focused ultrasound surgery (MRgFUS) is a quickly developing technology with potential applications across a spectrum of indications traditionally within the domain of radiation oncology. Especially for applications where focal treatment is the preferred technique (for example, radiosurgery), MRgFUS has the potential to be a disruptive technology that could shift traditional patterns of care. While currently cleared in the United States for the noninvasive treatment of uterine fibroids and bone metastases, a wide range of clinical trials are currently underway, and the number of publications describing advances in MRgFUS is increasing. However, for MRgFUS to make the transition from a research curiosity to a clinical standard of care, a variety of challenges, technical, financial, clinical, and practical, must be overcome. This installment of the Vision 20/20 series examines the current status of MRgFUS, focusing on the hurdles the technology faces before it can cross over from a research technique to a standard fixture in the clinic. It then reviews current and near-term technical developments which may overcome these hurdles and allow MRgFUS to break through into clinical practice.

  13. MR-guided focused ultrasound surgery, present and future

    International Nuclear Information System (INIS)

    Schlesinger, David; Benedict, Stanley; Diederich, Chris; Gedroyc, Wladyslaw; Klibanov, Alexander; Larner, James

    2013-01-01

    MR-guided focused ultrasound surgery (MRgFUS) is a quickly developing technology with potential applications across a spectrum of indications traditionally within the domain of radiation oncology. Especially for applications where focal treatment is the preferred technique (for example, radiosurgery), MRgFUS has the potential to be a disruptive technology that could shift traditional patterns of care. While currently cleared in the United States for the noninvasive treatment of uterine fibroids and bone metastases, a wide range of clinical trials are currently underway, and the number of publications describing advances in MRgFUS is increasing. However, for MRgFUS to make the transition from a research curiosity to a clinical standard of care, a variety of challenges, technical, financial, clinical, and practical, must be overcome. This installment of the Vision 20/20 series examines the current status of MRgFUS, focusing on the hurdles the technology faces before it can cross over from a research technique to a standard fixture in the clinic. It then reviews current and near-term technical developments which may overcome these hurdles and allow MRgFUS to break through into clinical practice

  14. The endoscopic ultrasound-assisted Rendez-Vous technique for treatment of recurrent pancreatitis due to pancreas divisum and ansa pancreatica

    Directory of Open Access Journals (Sweden)

    Sergio López-Durán

    Full Text Available Endoscopic treatment of pancreatic ductal malformations causing recurrent acute pancreatitis, such as pancreas divisum or ansa pancreatica, is mainly based on the sphincterotomy of the minor papilla. However, the technical complexity of conventional endoscopic retrograde cholangiopancreatography (ERCP is increased in patients presenting anatomical variants like these and it may be unsuccessful. We report the case of a pancreas divisum combined with ansa pancreatica and describe the cannulation and sphincterotomy of the minor papilla using an ultrasound-assisted Rendez-Vous technique.

  15. Ultrasound-guided versus computed tomography-scan guided biopsy of pleural-based lung lesions.

    Science.gov (United States)

    Khosla, Rahul; McLean, Anna W; Smith, Jessica A

    2016-01-01

    Computed tomography (CT) guided biopsies have long been the standard technique to obtain tissue from the thoracic cavity and is traditionally performed by interventional radiologists. Ultrasound (US) guided biopsy of pleural-based lesions, performed by pulmonologists is gaining popularity and has the advantage of multi-planar imaging, real-time technique, and the absence of radiation exposure to patients. In this study, we aim to determine the diagnostic accuracy, the time to diagnosis after the initial consult placement, and the complications rates between the two different modalities. A retrospective study of electronic medical records was done of patients who underwent CT-guided biopsies and US-guided biopsies for pleural-based lesions between 2005 and 2014 and the data collected were analyzed for comparing the two groups. A total of 158 patients underwent 162 procedures during the study period. 86 patients underwent 89 procedures in the US group, and 72 patients underwent 73 procedures in the CT group. The overall yield in the US group was 82/89 (92.1%) versus 67/73 (91.8%) in the CT group (P = 1.0). Average days to the procedure was 7.2 versus 17.5 (P = 0.00001) in the US and CT group, respectively. Complication rate was higher in CT group 17/73 (23.3%) versus 1/89 (1.1%) in the US group (P guided biopsy is similar to that of CT-guided biopsy, with a lower complication rate and a significantly reduced time to the procedure.

  16. Enhancing early bladder cancer detection with fluorescence-guided endoscopic optical coherence tomography

    Science.gov (United States)

    Pan, Y. T.; Xie, T. Q.; Du, C. W.; Bastacky, S.; Meyers, S.; Zeidel, M. L.

    2003-12-01

    We report an experimental study of the possibility of enhancing early bladder cancer diagnosis with fluorescence-image-guided endoscopic optical coherence tomography (OCT). After the intravesical instillation of a 10% solution of 5-aminolevulinic acid, simultaneous fluorescence imaging (excitation of 380-420 nm, emission of 620-700 nm) and OCT are performed on rat bladders to identify the photochemical and morphological changes associated with uroepithelial tumorigenesis. The preliminary results of our ex vivo study reveal that both fluorescence and OCT can identify early uroepithelial cancers, and OCT can detect precancerous lesions (e.g., hyperplasia) that fluorescence may miss. This suggests that a cystoscope combining 5-aminolevulinic acid fluorescence and OCT imaging has the potential to enhance the efficiency and sensitivity of early bladder cancer diagnosis.

  17. Confocal laser endomicroscopy and ultrasound endoscopy during the same endoscopic session for diagnosis and staging of gastric neoplastic lesions.

    Science.gov (United States)

    Gheorghe, C; Iacob, R; Dumbrava, Mona; Becheanu, G; Ionescu, M

    2009-01-01

    Confocal LASER endomicroscopy (CLE) is a newly developed endoscopic technique which allows subsurface in vivo histological assessment during ongoing endoscopy and targeted biopsies. Ultrasound endoscopy (EUS) is a useful tool in staging upper GI malignant lesions. We describe for the first time the use of both techniques during the same endoscopic session, in a pilot study, in order to increase the diagnostic yield of histological assessment and provide the staging of the gastric neoplastic lesions thus decreasing the time to therapeutic decision. CLE has been performed with the Pentax EG-3870CIK confocal endomicroscope after a 5 ml intravenous 10% fluorescein injection; EUS has been performed subsequently, during the same endoscopic Propofol sedation session, using a standard radial EUS-scope. Eleven patients have been investigated, 4 females, 7 males, mean age 59.7 +/- 12.3 years. The indication of CLE/EUS exploration was the presence of a gastric polypoid lesion in 37% of cases, atypical gastric ulcer in 27% of patients, gastric lymphoma 18%, suspicion of gastric cancer recurrence after resection 9% and infiltrating type gastric cancer 9%. Histological assessment after targeted biopsy has established the diagnosis of gastric adenocarcinoma in 55% of cases, gastric lymphoma in 18% of cases, gastric adenoma, gastric GIST and gastric foveolar hyperplasia in 9% of cases respectively. CLE has allowed targeted biopsies in 81.8% of cases. In 2 patients - one case with suspected recurrent gastric cancer after surgery and one case of gastric lymphoma, CLE has indicated normal gastric mucosa. The EUS evaluation has shown TO lesion in two cases, T1 in 3 cases, T2 in 3 cases, T3 in one case. The EUS evaluation showed in one gastric lymphoma patient a lesion interesting the mucosa and submucosa with regional adenopathy and a submucosal lesion with regional adenopathy in the other gastric lymphoma case. The therapeutic decision was surgery in 73% of cases, chemotherapy and

  18. Review of magnetic resonance-guided focused ultrasound in the treatment of uterine fibroids

    Directory of Open Access Journals (Sweden)

    Pedro Felipe Magalhães Peregrino

    Full Text Available Uterine leiomyoma is the most frequently occurring solid pelvic tumor in women during the reproductive period. Magnetic resonance-guided high-intensity focused ultrasound is a promising technique for decreasing menorrhagia and dysmenorrhea in symptomatic women. The aim of this study is to review the role of Magnetic resonance-guided high-intensity focused ultrasound in the treatment of uterine fibroids in symptomatic patients. We performed a review of the MEDLINE and Cochrane databases up to April 2016. The analysis and data collection were performed using the following keywords: Leiomyoma, High-Intensity Focused Ultrasound Ablation, Ultrasonography, Magnetic Resonance Imaging, Menorrhagia. Two reviewers independently performed a quality assessment; when there was a disagreement, a third reviewer was consulted. Nineteen studies of Magnetic resonance-guided high-intensity focused ultrasound-treated fibroid patients were selected. The data indicated that tumor size was reduced and that symptoms were improved after treatment. There were few adverse effects, and they were not severe. Some studies have reported that in some cases, additional sessions of Magnetic resonance-guided high-intensity focused ultrasound or other interventions, such as myomectomy, uterine artery embolization or even hysterectomy, were necessary. This review suggests that Magnetic resonance-guided high-intensity focused ultrasound is a safe and effective technique. However, additional evidence from future studies will be required before the technique can be recommended as an alternative treatment for fibroids.

  19. A new modified speculum guided single nostril technique for endoscopic transnasal transsphenoidal surgery: an analysis of nasal complications.

    Science.gov (United States)

    Waran, Vicknes; Tang, Ing Ping; Karuppiah, Ravindran; Abd Kadir, Khairul Azmi; Chandran, Hari; Muthusamy, Kalai Arasu; Prepageran, Narayanan

    2013-12-01

    Abstract The endoscopic transnasal, transsphenoidal surgical technique for pituitary tumour excision has generally been regarded as a less invasive technique, ranging from single nostril to dual nostril techniques. We propose a single nostril technique using a modified nasal speculum as a preferred technique. We initially reviewed 25 patients who underwent pituitary tumour excision, via endoscopic transnasal transsphenoidal surgery, using this new modified speculum-guided single nostril technique. The results show shorter operation time with reduced intra- and post-operative nasal soft tissue injuries and complications.

  20. Development and Implementation of an Ultrasound-Guided Peripheral Intravenous Catheter Program for Emergency Nurses.

    Science.gov (United States)

    Edwards, Courtney; Jones, Jodi

    2018-01-01

    Emergency medical care often necessitates placement of peripheral intravenous (PIV) catheters. When traditional methods for obtaining PIV access are not successful, ultrasound guidance is a rescue technique for peripheral vascular placement that improves the quality of patient care. The aim of this training program was to develop a process where emergency nurses would be competent to perform ultrasound guided PIV to improve the quality of patient care delivered while reducing throughput time. Administrative program development required creating a nursing practice statement, procedure guideline, operational plan, and competency validation. A training program comprising both didactic and hands-on training was developed and provided by emergency medicine physicians with formal ultrasound fellowship training. In determining whether the training program was adequate in preparing the student to place an ultrasound-guided PIV, 92.9% of students "agreed" or "strongly agreed." In having confidence in their ability to obtain an ultrasound guided PIV catheter placement, 35.7% of respondents "agreed" and 64.3% "strongly agreed." In finding it difficult to be successful in achieving ultrasound guided PIV catheter placement, 71.4% of students "strongly disagreed" and 14.3% "disagreed." All students (100%) felt it was a feasible task to train nurses to successfully place ultrasound-guided PIV catheters and 71.4% of students strongly support continuing to provide this training program and competency validation. Establishment of an effective didactic and hands-on training program resulted in emergency department nurses becoming competent in placement of ultrasound guided PIV catheters to provide optimal patient care. Copyright © 2017 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.

  1. Ultrasound-guided compression repair of pseudoaneurysms of brachial and femoral arteries - 2 cases-

    International Nuclear Information System (INIS)

    Kim, Hak Soo; Choi, Yeon Hyeon; Kim, Ji Eun; Lee, Sang Hoon; Kim, Myung A; Kim, Tae Kyoung; Cho, Jae Min

    1994-01-01

    Ultrasound-guided compression repair of postcatherization pseudoaneurysm has been reported recently. We successfuly treated two cases of cardiac catherization-related pseudoaneurysms of brachial and femoral arteries with compression repair technique under color Doppler US-guidance. We regard US-guided compression repair as a saft and effective first-line treatment for catherization-related pseudoaneurysm

  2. Glenohumeral joint injection: a comparative study of ultrasound and fluoroscopically guided techniques before MR arthrography.

    NARCIS (Netherlands)

    Rutten, M.J.; Collins, J.M.; Maresch, B.J.; Smeets, J.H.R.; Janssen, C.M.; Kiemeney, L.A.L.M.; Jager, G.J.

    2009-01-01

    To assess the variability in accuracy of contrast media introduction, leakage, required time and patient discomfort in four different centres, each using a different image-guided glenohumeral injection technique. Each centre included 25 consecutive patients. The ultrasound-guided anterior (USa) and

  3. Ultrasound guided percutaneous cholecystostomy in high-risk patients for surgical intervention

    Science.gov (United States)

    Bakkaloglu, Huseyin; Yanar, Hakan; Guloglu, Recep; Taviloglu, Korhan; Tunca, Fatih; Aksoy, Murat; Ertekin, Cemalettin; Poyanli, Arzu

    2006-01-01

    AIM: To assess the efficacy and safety of ultrasound guided percutaneous cholecystostomy (PC) in the treatment of acute cholecystitis in a well-defined high risk patients under general anesthesia. METHODS: The data of 27 consecutive patients who underwent percutaneous transhepatic cholecystostomy for the management of acute cholecystitis from January 1999 to June 2003 was retrospectively evaluated. All of the patients had both clinical and sonographic signs of acute cholecystitis and had comorbid diseases. RESULTS: Ultrasound revealed gallbladder stones in 25 patients and acalculous cholecystitis in two patients. Cholecystostomy catheters were removed 14-32 d (mean 23 d) after the procedure in cases where complete regression of all symptoms was achieved. There were statistically significant reductions in leukocytosis, (13.7 × 103 ± 1.3 × 103 μg/L vs 13 × 103 ± 1 × 103 μg/L, P < 0.05 for 24 h after PC; 13.7 × 103 ± 1.3 × 103 μg/L vs 8.3 × 103 ± 1.2 × 103 μg/L, P < 0.0001 for 72 h after PC), C -reactive protein (51.2 ± 18.5 mg/L vs 27.3 ± 10.4 mg/L, P < 0.05 for 24 h after PC; 51.2 ± 18.5 mg/L vs 5.4 ± 1.5 mg/L, P < 0.0001 for 72 h after PC), and fever (38 ± 0.35°C vs 37.3 ± 0.32°C, P < 0.05 for 24 h after PC; 38 ± 0.35°C vs 36.9 ± 0.15°C, P < 0.0001 for 72 h after PC). Sphincterotomy and stone extraction was performed successfully with endoscopic retrograde cholangio-pancreatography (ERCP) in three patients. After cholecystostomy, 5 (18%) patients underwent delayed cholecystectomy without any complications. Three out of 22 patients were admitted with recurrent acute cholecystitis during the follow-up and recovered with medical treatment. Catheter dislodgement occurred in three patients spontaneously, and two of them were managed by reinsertion of the catheter. CONCLUSION: As an alternative to surgery, percutan-eous cholecystostomy seems to be a safe method in critically ill patients with acute cholecystitis and can be performed with low

  4. Ultrasound Guided Nerve Root Injection in Patients with Cervical Spondylytic Radicular Pain

    Directory of Open Access Journals (Sweden)

    LT Choong

    2009-05-01

    Full Text Available Selective cervical nerve root injection using a mixture of corticosteroid and lignocaine is a treatment option for managing cervical radiculopathic pain. The procedure is usually performed under image guided fluoroscopy or Computerized Tomograhy. Ultrasound-guided cervical nerve root block does not expose the patients and personnel to radiation. During injection, the fluid is mostly visualized in a real-time fashion. This retrospective study reviewed the effectiveness of ultrasound in guiding cervical peri-radicular injection for pain relief in patients with recalcitrant cervical radiculopathy. There were no complications reported in this series.

  5. Success of ultrasound-guided versus landmark-guided arthrocentesis of hip, ankle, and wrist in a cadaver model.

    Science.gov (United States)

    Berona, Kristin; Abdi, Amin; Menchine, Michael; Mailhot, Tom; Kang, Tarina; Seif, Dina; Chilstrom, Mikaela

    2017-02-01

    The objectives of this study were to evaluate emergency medicine resident-performed ultrasound for diagnosis of effusions, compare the success of a landmark-guided (LM) approach with an ultrasound-guided (US) technique for hip, ankle and wrist arthrocentesis, and compare change in provider confidence with LM and US arthrocentesis. After a brief video on LM and US arthrocentesis, residents were asked to identify artificially created effusions in the hip, ankle and wrist in a cadaver model and to perform US and LM arthrocentesis of the effusions. Outcomes included success of joint aspiration, time to aspiration, and number of attempts. Residents were surveyed regarding their confidence in identifying effusions with ultrasound and performing LM and US arthrocentesis. Eighteen residents completed the study. Sensitivity of ultrasound for detecting joint effusion was 86% and specificity was 90%. Residents were successful with ultrasound in 96% of attempts and with landmark 89% of attempts (p=0.257). Median number of attempts was 1 with ultrasound and 2 with landmarks (p=0.12). Median time to success with ultrasound was 38s and 51s with landmarks (p=0.23). After the session, confidence in both US and LM arthrocentesis improved significantly, however the post intervention confidence in US arthrocentesis was higher than LM (4.3 vs. 3.8, p<0.001). EM residents were able to successfully identify joint effusions with ultrasound, however we were unable to detect significant differences in actual procedural success between the two modalities. Further studies are needed to define the role of ultrasound for arthrocentesis in the emergency department. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Ultrasound-guided injection of triamcinolone and bupivacaine in the management of De Quervain's disease.

    Science.gov (United States)

    Jeyapalan, Kanagaratnam; Choudhary, Surabhi

    2009-11-01

    The aim of this study was to describe the technique and usefulness of ultrasound-guided intrasynovial injection of triamcinolone and bupivacaine in treatment of de Quervain's disease. A total of 17 patients with symptomatic De Quervain's disease were included in this study. The procedure involved confirmation of diagnosis with ultrasound followed by guided injection of a mixture of 20 mg of triamcinolone (40 mg/ml) and 1 ml of 0.5% bupivacaine. Ultrasound guidance with a high resolution 15-Mhz footprint probe was used for injection into the first dorsal extensor compartment tendon sheath (E1). The response to ultrasound-guided injection was ascertained at the post procedure outpatient clinic appointment according to the follow-up clinic notes. There were 14 female and 3 male patients aged 29 to 74 years. Mean duration of symptoms was 8.9 months. One patient had an atypical septum in the first extensor compartment and the extensor pollicis brevis alone was involved. The mean post-injection follow-up was at 6.75 weeks. One patient was lost to follow-up. Fifteen out of 16 patients had significant symptomatic relief (93.75%). There were no immediate or delayed complications. Recurrence of symptoms was seen in 3 (20%) patients. Ultrasound-guided injection of triamcinolone and bupivacaine is safe and useful in controlling symptoms of De Quervain's disease. Correct needle placement with ultrasound guidance avoids intratendinous injection as well as local complications like fat atrophy and depigmentation.

  7. PLUS: open-source toolkit for ultrasound-guided intervention systems.

    Science.gov (United States)

    Lasso, Andras; Heffter, Tamas; Rankin, Adam; Pinter, Csaba; Ungi, Tamas; Fichtinger, Gabor

    2014-10-01

    A variety of advanced image analysis methods have been under the development for ultrasound-guided interventions. Unfortunately, the transition from an image analysis algorithm to clinical feasibility trials as part of an intervention system requires integration of many components, such as imaging and tracking devices, data processing algorithms, and visualization software. The objective of our paper is to provide a freely available open-source software platform-PLUS: Public software Library for Ultrasound-to facilitate rapid prototyping of ultrasound-guided intervention systems for translational clinical research. PLUS provides a variety of methods for interventional tool pose and ultrasound image acquisition from a wide range of tracking and imaging devices, spatial and temporal calibration, volume reconstruction, simulated image generation, and recording and live streaming of the acquired data. This paper introduces PLUS, explains its functionality and architecture, and presents typical uses and performance in ultrasound-guided intervention systems. PLUS fulfills the essential requirements for the development of ultrasound-guided intervention systems and it aspires to become a widely used translational research prototyping platform. PLUS is freely available as open source software under BSD license and can be downloaded from http://www.plustoolkit.org.

  8. Sensitivity of endoscopic ultrasound, multidetector computed tomography, and magnetic resonance cholangiopancreatography in the diagnosis of pancreas divisum: a tertiary center experience.

    Science.gov (United States)

    Kushnir, Vladimir M; Wani, Sachin B; Fowler, Kathryn; Menias, Christine; Varma, Rakesh; Narra, Vamsi; Hovis, Christine; Murad, Faris M; Mullady, Daniel K; Jonnalagadda, Sreenivasa S; Early, Dayna S; Edmundowicz, Steven A; Azar, Riad R

    2013-04-01

    There are limited data comparing imaging modalities in the diagnosis of pancreas divisum. We aimed to: (1) evaluate the sensitivity of endoscopic ultrasound (EUS), magnetic resonance cholangiopancreatography (MRCP), and multidetector computed tomography (MDCT) for pancreas divisum; and (2) assess interobserver agreement (IOA) among expert radiologists for detecting pancreas divisum on MDCT and MRCP. For this retrospective cohort study, we identified 45 consecutive patients with pancreaticobiliary symptoms and pancreas divisum established by endoscopic retrograde pancreatography who underwent EUS and cross-sectional imaging. The control group was composed of patients without pancreas divisum who underwent endoscopic retrograde pancreatography and cross-sectional imaging. The sensitivity of EUS for pancreas divisum was 86.7%, significantly higher than the sensitivity reported in the medical records for MDCT (15.5%) or MRCP (60%) (P pancreas divisum; IOA was moderate (κ = 0.43). Endoscopic ultrasound is a sensitive test for diagnosing pancreas divisum and is superior to MDCT and MRCP. Review of MDCT studies by expert radiologists substantially raises its sensitivity for pancreas divisum.

  9. Comparison of treatment outcomes of endoscope-guided pneumatic dilation and laparoscopic Heller myotomy.

    Science.gov (United States)

    Wang, Hsin-Ming; Tai, Wei-Chen; Chuah, Seng-Kee; Lu, Hung-I; Lu, Lung-Sheng; Liang, Chih-Ming; Kuo, Chung-Huang; Chiu, Yi-Chun; Wu, Keng-Liang; Changchien, Chi-Sin

    2015-12-01

    The debate on which is the better choice between laparoscopic Heller myotomy (LHM) and endoscopic pneumatic dilation (PD) for esophageal achalasia has been ongoing for decades. This study aims to compare the results of endoscope-guided PD and LHM in 42 patients with achalasia between May 1996 and August 2011. Twenty-one patients who had received PD and 21 who had received LHM were enrolled. The cumulative remission rate was analyzed using the Kaplan-Meier method with the assessment of symptom scores between grades before and after PD or LHM done at 6 weeks, 6 months, 1 year, and then every year thereafter. Possible confounding factors related to the remissions were analyzed by Cox's proportional hazard model. For PD, the cumulative remission rates were 81.0% (1 year), 76.2% (2), 66.7% (3), 61.9% (4), and 47.6% (5). For LHM, the cumulative remission rates were 90.5% every year from the 1(st) to the 5(th). The LHM patients had significantly better remission rates than the PD patients (p = 0.033, by log-rank test). The LHM group had a longer hospital stay than the PD group [median (interquartile range): 8 (6.5-10) days vs. 3 (2-3) days, p < 0.001) and had more reflux complications (52.4% vs. 19.0%, p = 0.024). No perforation occurred in either group. In conclusion, the 5-year cumulative effectiveness of LHM is better than that of PD despite the association of LHM with more reflux events (52.4%). Copyright © 2015. Published by Elsevier Taiwan.

  10. Comparison of treatment outcomes of endoscope-guided pneumatic dilation and laparoscopic Heller myotomy

    Directory of Open Access Journals (Sweden)

    Hsin-Ming Wang

    2015-12-01

    Full Text Available The debate on which is the better choice between laparoscopic Heller myotomy (LHM and endoscopic pneumatic dilation (PD for esophageal achalasia has been ongoing for decades. This study aims to compare the results of endoscope-guided PD and LHM in 42 patients with achalasia between May 1996 and August 2011. Twenty-one patients who had received PD and 21 who had received LHM were enrolled. The cumulative remission rate was analyzed using the Kaplan–Meier method with the assessment of symptom scores between grades before and after PD or LHM done at 6 weeks, 6 months, 1 year, and then every year thereafter. Possible confounding factors related to the remissions were analyzed by Cox's proportional hazard model. For PD, the cumulative remission rates were 81.0% (1 year, 76.2% (2, 66.7% (3, 61.9% (4, and 47.6% (5. For LHM, the cumulative remission rates were 90.5% every year from the 1st to the 5th. The LHM patients had significantly better remission rates than the PD patients (p = 0.033, by log-rank test. The LHM group had a longer hospital stay than the PD group [median (interquartile range: 8 (6.5–10 days vs. 3 (2–3 days, p < 0.001 and had more reflux complications (52.4% vs. 19.0%, p = 0.024. No perforation occurred in either group. In conclusion, the 5-year cumulative effectiveness of LHM is better than that of PD despite the association of LHM with more reflux events (52.4%.

  11. Cost-effectiveness analysis of endoscopic ultrasound versus magnetic resonance cholangiopancreatography in patients with suspected common bile duct stones.

    Directory of Open Access Journals (Sweden)

    Stephen Morris

    Full Text Available Patients with suspected common bile duct (CBD stones are often diagnosed using endoscopic retrograde cholangiopancreatography (ERCP, an invasive procedure with risk of significant complications. Using endoscopic ultrasound (EUS or Magnetic Resonance CholangioPancreatography (MRCP first to detect CBD stones can reduce the risk of unnecessary procedures, cut complications and may save costs.This study sought to compare the cost-effectiveness of initial EUS or MRCP in patients with suspected CBD stones.This study is a model based cost-utility analysis estimating mean costs and quality-adjusted life years (QALYs per patient from the perspective of the UK National Health Service (NHS over a 1 year time horizon. A decision tree model was constructed and populated with probabilities, outcomes and cost data from published sources, including one-way and probabilistic sensitivity analyses.Using MRCP to select patients for ERCP was less costly than using EUS to select patients or proceeding directly to ERCP ($1299 versus $1753 and $1781, respectively, with similar QALYs accruing to each option (0.998, 0.998 and 0.997 for EUS, MRCP and direct ERCP, respectively. Initial MRCP was the most cost-effective option with the highest monetary net benefit, and this result was not sensitive to model parameters. MRCP had a 61% probability of being cost-effective at $29,000, the maximum willingness to pay for a QALY commonly used in the UK.From the perspective of the UK NHS, MRCP was the most cost-effective test in the diagnosis of CBD stones.

  12. Ultrasound-guided radiofrequency neurotomy in cervical spine: sonoanatomic study of a new technique in cadavers

    International Nuclear Information System (INIS)

    Lee, S.-H.; Kang, C.H.; Lee, S.-H.; Derby, R.; Yang, S.N.; Lee, J.E.; Kim, J.H.; Kim, S.S.; Lee, J.-H.

    2008-01-01

    Aim: To develop an ultrasound-guided technique for radiofrequency (RF) cervical medial branch neurotomy and to validate the accuracy of this new method. Materials and methods: Five non-embalmed, fresh cadavers were used; three male and two female cadavers with a median age at death of 67.2 years (range 50-84 years). This study was conducted in two parts. First, two of the cadavers were used to define the sonographic target point for RF cervical medial branch neurotomy using high-resolution ultrasound (12 to 5 MHz). The needles were guided to five consecutive cervical medial branches in the cadavers under ultrasound guidance. Subsequently, the position of the ultrasound-guided needle was verified using C-arm fluoroscopy. Ultrasound-guided RF neurotomy was performed to the C5 medial branches in all five cadavers. In the three cadavers not used in the first part of the study, ultrasound-guided RF neurotomy without C-arm fluoroscopic confirmation was performed to the C3-C7 medial branches. The accuracy of neurotomy was assessed by pathological examination of the cervical medial branches obtained through cadaver dissection. Results: In all five cadavers, the sonographic target point was identified in all C3-C7 segments with the 12 to 5 MHz linear transducer. In all 20 needle placements for the first and second cadavers, C-arm fluoroscopy validated proper needle tip positions. In all five cadavers, successful neurotomy was pathologically confirmed in 30 of 34 cervical medial branches. Conclusions: Ultrasound-guided cervical medial branch neurotomy was successfully performed in 30 of 34 cervical medial branches in five cadavers. However, before eliminating fluoroscopic validation of final needle tip positioning, the technique should be validated in symptomatic patients

  13. A long arm for ultrasound: a combined robotic focused ultrasound setup for magnetic resonance-guided focused ultrasound surgery.

    Science.gov (United States)

    Krafft, Axel J; Jenne, Jürgen W; Maier, Florian; Stafford, R Jason; Huber, Peter E; Semmler, Wolfhard; Bock, Michael

    2010-05-01

    Focused ultrasound surgery (FUS) is a highly precise noninvasive procedure to ablate pathogenic tissue. FUS therapy is often combined with magnetic resonance (MR) imaging as MR imaging offers excellent target identification and allows for continuous monitoring of FUS induced temperature changes. As the dimensions of the ultrasound (US) focus are typically much smaller than the targeted volume, multiple sonications and focus repositioning are interleaved to scan the focus over the target volume. Focal scanning can be achieved electronically by using phased-array US transducers or mechanically by using dedicated mechanical actuators. In this study, the authors propose and evaluate the precision of a combined robotic FUS setup to overcome some of the limitations of the existing MRgFUS systems. Such systems are typically integrated into the patient table of the MR scanner and thus only provide an application of the US wave within a limited spatial range from below the patient. The fully MR-compatible robotic assistance system InnoMotion (InnoMedic GmbH, Herxheim, Germany) was originally designed for MR-guided interventions with needles. It offers five pneumatically driven degrees of freedom and can be moved over a wide range within the bore of the magnet. In this work, the robotic system was combined with a fixed-focus US transducer (frequency: 1.7 MHz; focal length: 68 mm, and numerical aperture: 0.44) that was integrated into a dedicated, in-house developed treatment unit for FUS application. A series of MR-guided focal scanning procedures was performed in a polyacrylamide-egg white gel phantom to assess the positioning accuracy of the combined FUS setup. In animal experiments with a 3-month-old domestic pig, the system's potential and suitability for MRgFUS was tested. In phantom experiments, a total targeting precision of about 3 mm was found, which is comparable to that of the existing MRgFUS systems. Focus positioning could be performed within a few seconds

  14. Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

    Directory of Open Access Journals (Sweden)

    Szkup Peter

    2006-05-01

    Full Text Available Abstract Background Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. Case presentation During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. Conclusion The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound

  15. The effect of ultrasound-guided compression immediately after transrectal ultrasound-guided prostate biopsy on postbiopsy bleeding: a randomized controlled pilot study.

    Science.gov (United States)

    Park, Bong Hee; Kim, Jung Im; Bae, Sang Rak; Lee, Yong Seok; Kang, Sung Hak; Han, Chang Hee

    2017-08-01

    To evaluate whether ultrasound-guided compression performed immediately after transrectal ultrasound (TRUS)-guided prostate biopsy decreases bleeding complications. We prospectively evaluated a total of 148 consecutive patients who underwent TRUS-guided prostate biopsy between March 2015 and July 2016. Systematic 12-core prostate biopsy was performed in all patients. Of these, 100 patients were randomly assigned to one of two groups: the compression group (n = 50) underwent TRUS-guided compression on bleeding biopsy tracts immediately after prostate biopsy, while the non-compression group (n = 50) underwent TRUS-guided prostate biopsy alone. The incidence rate and duration of hematuria, hematospermia, and rectal bleeding were compared between the two groups. The incidence rates of hematuria and hematospermia were not significantly different between the two groups (60 vs. 64%, p = 0.68; 22 vs. 30%, p = 0.362, respectively, for compression vs. non-compression group). The rectal bleeding incidence was significantly lower in the compression group as compared to the non-compression group (20 vs. 44%, p = 0.01). However, there were no significant differences in the median duration of hematuria, hematospermia, or rectal bleeding between the two groups (2, 8, and 2 days vs. 2, 10, and 1 days, p > 0.05, respectively, for compression vs. non-compression group). TRUS-guided compression [p = 0.004, odds ratio (OR) 0.25] and patient age (p = 0.013, OR 0.93) were significantly protective against the occurrence of rectal bleeding after prostate biopsy in multivariable analysis. Although it has no impact on other complications, ultrasound-guided compression on bleeding biopsy tracts performed immediately after TRUS-guided prostate biopsy is an effective and practical method to treat or decrease rectal bleeding.

  16. Regression of gastric malt-lymphoma under specific therapy may be predict by endoscopic ultrasound.

    Science.gov (United States)

    Gheorghe, Cristian; Băncilă, Ion; Stoia, Răzvan; Gheorghe, Liana; Becheanu, Gabriel; Dobre, Camelia; Brescan, Raluca

    2004-06-01

    Mucosa-associated lymphoid tissue (MALT) lymphomas represent a relatively new described class of rare lymphomas, characterized by an indolent course and favourable outcome with specific therapy. Gastric MALT lymphomas are associated with chronic Helicobacter pylori (HP) infection. We report the case of a 67 year old man admitted for an 8-month history of epigastric pain, anorexia and progressive weight loss. He was diagnosed with low-grade primary gastric MALT lymphoma by endoscopy, histopathological examination of gastric mucosa (light microscopy and immunohistochemistry) and endoscopic ultrasonography (EUS). The patient received a 2-week course of anti-HP therapy and chemotherapy with Chlorambucil 0.1 mg/kg/day was started. During the follow-up, continuous improvement of clinical status, endoscopic and EUS appearance was noted. We conclude that, facing the trend toward nonsurgical treatment modalities for primary gastric lymphoma, EUS appears an important tool for staging the disease and defining cases suitable for anti-HP, radio- and chemotherapy, as well as for the detection of local recurrence.

  17. Urinary morbidity following ultrasound-guided transperineal prostate seed implantation

    International Nuclear Information System (INIS)

    Gelblum, Daphna Y.; Potters, Louis; Ashley, Richard; Waldbaum, Robert; Wang Xiaohong; Leibel, Steven

    1999-01-01

    Purpose: To assess the urinary morbidity experienced by patients undergoing ultrasound-guided, permanent transperineal seed implantation for adenocarcinoma of the prostate. Methods and Materials: Between September 1992 and September 1997, 693 consecutive patients presented with a diagnosis of clinically localized adenocarcinoma of the prostate, and were treated with ultrasound-guided transperineal interstitial permanent brachytherapy (TPIPB). Ninety-three patients are excluded from this review, having received neoadjuvant antiandrogen therapy. TPIPB was performed with 125 I in 165 patients and with 103 Pd in 435 patients. Patients treated with implant alone received 160 Gy with 125 I (pre TG43) or 120 Gy with 103 Pd. One hundred two patients received preimplant, pelvic external beam radiation (XRT) to a dose of either 41.4 or 45 Gy because of high-risk features including PSA ≥ 10 and/or Gleason score ≥ 7. Combined modality patients received 120 Gy and 90 Gy, respectively for 125 I or 103 Pd. All patients underwent postimplant cystoscopy and placement of an indwelling Foley catheter for 24-48 h. Follow-up was at 5 weeks after implant, every 3 months for the first 2 years, and then every 6 months for subsequent years. Patients completed AUA urinary symptom scoring questionnaires at initial consultation and at each follow-up visit. Urinary toxicity was classified by the RTOG toxicity scale with the following adaptations; grade 1 urinary toxicity was symptomatic nocturia or frequency requiring none or minimal medical intervention such as phenazopyridine; grade 2 urinary toxicity was early obstructive symptomatology requiring alpha-blocker therapy; and grade 3 toxicity was considered that requiring indwelling catheters or posttreatment transurethral resection of the prostate for symptom relief. Log-rank analysis and Chi-square testing was performed to assess AUA score, prostate size, isotope selection, and the addition of XRT as possible prognosticators of

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose a variety of heart ... Articles and Media Angioplasty and Vascular Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview ...

  19. A practical guide to ultrasound in obstetrics and gynecology

    International Nuclear Information System (INIS)

    Sauerbrei, E.E.; Nguyen, K.T.; Nolan, R.L.

    1986-01-01

    This book reviews the indications for ultrasound during pregnancy and establishes guidelines for conducting obstetrical ultrasound examinations. A selection of scans follows. These scans depict normal female pelvic anatomy; the nongravid uterus; the ovaries and adnexae; early pregnancy (the embryonic period); the placenta; the membranes, amniotic fluid, and umbilical cord; the uterus and adnexae in pregnancy; and the fetus. The book contains information on making accurate fetal measurements and calculations

  20. A successful model to learn and implement ultrasound-guided venous catheterization in apheresis.

    Science.gov (United States)

    Gopalasingam, Nigopan; Thomsen, Anna-Marie Eller; Folkersen, Lars; Juhl-Olsen, Peter; Sloth, Erik

    2017-12-01

    Apheresis treatments can be performed with peripheral venous catheters (PVC), although central venous catheters (CVC) are inserted when PVCs fail or patient with history of difficult vascular access prior to the apheresis. Ultrasound guidance for PVC has shown promising results in other settings. To investigate if ultrasound guidance for PVC could be implemented among apheresis nurses. Second, how implementation of ultrasound guidance affected the number of CVCs used for apheresis per patient. Apheresis nurses completed a systematic training program for ultrasound-guided vascular access. All independent catheterizations were registered during the implementation stage. The number of CVCs in the pre- and postimplementation stages of the ultrasound guidance was compared. Six nurses completed the training program within a median of 48 days (range 38-83 days). In 77 patients, 485 independent ultrasound-guided PVC placements were performed during the implementation stage. All apheresis treatments (485/485) were accomplished using PVCs without requiring CVC as rescue. During the preimplementation stage, 125 of 273 (45.8%) procedures required a CVC for completion of apheresis procedures; during the postimplementation stage only 30 of 227 (13.2%) procedures required a CVC (p < 0.001). In the postimplementation stage, no CVCs were placed as rescue caused by failed PVCs but were only placed for patients where the ultrasound machine was unavailable. It indicates an effective success rate of 100% for ultrasound-guided PVC use. This study showed that ultrasound guidance could be implemented among apheresis nurses as a routine tool eliminating the need of CVC as a rescue. © 2017 Wiley Periodicals, Inc.

  1. Noninvasive Label-Free Detection of Micrometastases in the Lymphatics with Ultrasound-Guided Photoacoustic Imaging

    Science.gov (United States)

    2015-10-01

    imaging can be used to guide dissection. We have also successfully integrated a programmable ultrasound machine ( Verasonics Vantage ) and tunable pulsed...Mobile HE) with the programmable ultrasound machine ( Verasonics Vantage ). We have synchronized the signals to enable interleaved acquisition of US...transducer (L11-4v, Verasonics Inc.) and build a housing which effectively couples fiber optic light delivery. o What opportunities for training and

  2. Standards of the Polish Ultrasound Society – update. Ultrasound examination of thyroid gland and ultrasound-guided thyroid biopsy

    Directory of Open Access Journals (Sweden)

    Anna Trzebińska

    2014-03-01

    Full Text Available Ultrasonography is a primary imaging technique in patients with suspected thyroid disease. It allows to assess the location, size and echostructures of the thyroid gland as well as detect focal lesions, along with indication of their size, echogenicity, echostructure and vascularity. Based on these features, ultrasound examination allows to predict abnormal focal lesions for biopsy and monitor the biopsy needle track. This paper presents the standards of thyroid ultrasound examination regarding ultrasound apparatus technical requirements, scanning techniques, readings, measurements, and the description of the examination. It discusses the ultrasound features of increased malignancy risk in focal lesions (nodules found in the thyroid gland. It presents indications for fine needle aspiration biopsy of the thyroid gland for the visibility of single nodules (focal lesions and numerous lesions as well as discusses contraindications for thyroid biopsy. It describes the biopsy technique, possible complications and rules for post-biopsy monitoring of benign lesions. The paper is an update of the Standards of the Polish Ultrasound Society issued in 2011. It has been prepared on the basis of current literature, taking into account the information contained in the following publications: Thyroid ultrasound examination and Recommendations of the Polish Ultrasound Society for the performance of the FNAB of the thyroid.

  3. Ultrasound-guided thoracenthesis: the V-point as a site for optimal drainage positioning.

    Science.gov (United States)

    Zanforlin, A; Gavelli, G; Oboldi, D; Galletti, S

    2013-01-01

    In the latest years the use of lung ultrasound is increasing in the evaluation of pleural effusions, because it makes follow-up easier and drainage more efficient by providing guidance on the most appropriate sampling site. However, no standardized approach for ultrasound-guided thoracenthesis is actually available. To evaluate our usual ultrasonographic landmark as a possible standard site to perform thoracenthesis by assessing its value in terms of safety and efficiency (success at first attempt, drainage as complete as possible). Hospitalized patients with non organized pleural effusion underwent thoracenthesis after ultrasound evaluation. The point showing on ultrasound the maximum thickness of the effusion ("V-point") was chosen for drainage. 45 ultrasound guided thoracenthesis were performed in 12 months. In 22 cases there were no complications; 16 cases of cough, 2 cases of mild dyspnea without desaturation, 4 cases of mild pain; 2 cases of complications requiring medical intervention occurred. No case of pneumothorax related to the procedure was detected. In all cases drainage was successful on the first attempt. The collected values of maximum thickness at V-point (min 3.4 cm - max 15.3 cm) and drained fluid volume (min 70 ml - max 2000 ml) showed a significative correlation (p measure of the maximum thickness at V-point provides high efficiency to ultrasound guided thoracentesis and allows to estimate the amount of fluid in the pleural cavity. It is also an easy parameter that makes the proposed method quick to learn and apply.  

  4. [An easy, safe and affective method for the treatment of intussusception: ultrasound-guided hydrostatic reduction].

    Science.gov (United States)

    Ülger, Fatma Esra Bahadır; Ülger, Aykut; Karakaya, Ali Erdal; Tüten, Fatih; Katı, Ömer; Çolak, Mustafa

    2014-03-01

    Intussusception is one of the important causes of intestinal obstruction in children. Hydrostatic reduction under ultrasound guidance is a popular treatment method for intussusception. In the present study, we aimed to explain the demographic characteristics of and treatment approaches in patients diagnosed with intussusception by ultrasound. Forty-one patients diagnosed with intussusception by ultrasound between August 2011 and May 2013 were retrospectively analyzed. Twenty-four of these patients who had no contraindications had been treated with ultrasound-guided hydrostatic reduction. Twenty-four of the patients were male and 17 were female, a 1.4/1 male-to-female ratio. The majority of the patients were between the ages of 6-24 months and 2-5 years. The mean age was 31.12±26.32 months (range 3-125). Patients were more frequently diagnosed in April and May. Seventeen patients who had clinical contraindications enrolled directly for surgery. In 20 of the 24 patients who underwent ultrasound-guided hydrostatic reduction, reduction was achieved. Three experienced recurrence. In two of these patients, successful reduction was achieved with the second attempt. The remaining patient was enrolled for surgery. Hydrostatic reduction was performed 26 times on these 24 patients, and in 22, success was achieved (84.6%). No procedure-related complications occurred in the patients. Ultrasound-guided hydrostatic reduction, with its high success rates and lack of radiation risk, should be the first choice therapeutic approach for children diagnosed with intussusception.

  5. Contrast-enhanced ultrasound-guided radiofrequency ablation in inconspicuous hepatocellular carcinoma on B-mode ultrasound.

    Science.gov (United States)

    Kim, Eui Joo; Kim, Yun Soo; Shin, Seung Kak; Kwon, Oh Sang; Choi, Duck Joo; Kim, Ju Hyun

    2017-11-01

    B-mode ultrasound (US) has difficulty targeting small hepatocellular carcinomas (HCCs) with poor conspicuity during radiofrequency ablation (RFA). Contrast-enhanced ultrasound (CEUS) can improve visualization of small or inconspicuous HCCs. This study was conducted to evaluate the effectiveness of CEUS-guided RFA electrode insertion during the arterial phase in inconspicuous HCCs. Ninety-three treatment-naïve HCCs from 80 patients treated with RFA from August 2012 to December 2014 were retrospectively reviewed. Seventy-five HCCs from 65 patients underwent B-mode US-guided RFA, and 15 HCCs from 14 patients that were inconspicuous on B-mode US underwent CEUS-guided RFA during the arterial phase after injection of sulfur hexafluoride microbubbles (SonoVue®). Technical success was assessed by contrast-enhanced computed tomography within 1 week and 3 months after the procedure. The mean size of HCCs treated with CEUS-guided RFA was smaller than that of HCCs treated with B-mode US-guided RFA (1.17±0.36 vs. 1.63±0.55 cm, p=0.003). Technical success rates of CEUS-guided RFA within 1 week and 3 months were 100% (15/15) and 93.3% (14/15), respectively. Technical success rates of B-mode US-guided RFA were 97.3% (73/75) and 94.5% (69/73), respectively. CEUS-guided RFA is highly efficacious for ablation of very small and inconspicuous HCCs.

  6. Backscattering analysis of high frequency ultrasonic imaging for ultrasound-guided breast biopsy

    Science.gov (United States)

    Cummins, Thomas; Akiyama, Takahiro; Lee, Changyang; Martin, Sue E.; Shung, K. Kirk

    2017-03-01

    A new ultrasound-guided breast biopsy technique is proposed. The technique utilizes conventional ultrasound guidance coupled with a high frequency embedded ultrasound array located within the biopsy needle to improve the accuracy in breast cancer diagnosis.1 The array within the needle is intended to be used to detect micro- calcifications indicative of early breast cancers such as ductal carcinoma in situ (DCIS). Backscattering analysis has the potential to characterize tissues to improve localization of lesions. This paper describes initial results of the application of backscattering analysis of breast biopsy tissue specimens and shows the usefulness of high frequency ultrasound for the new biopsy related technique. Ultrasound echoes of ex-vivo breast biopsy tissue specimens were acquired by using a single-element transducer with a bandwidth from 41 MHz to 88 MHz utilizing a UBM methodology, and the backscattering coefficients were calculated. These values as well as B-mode image data were mapped in 2D and matched with each pathology image for the identification of tissue type for the comparison to the pathology images corresponding to each plane. Microcalcifications were significantly distinguished from normal tissue. Adenocarcinoma was also successfully differentiated from adipose tissue. These results indicate that backscattering analysis is able to quantitatively distinguish tissues into normal and abnormal, which should help radiologists locate abnormal areas during the proposed ultrasound-guided breast biopsy with high frequency ultrasound.

  7. Disinfection of a probe used in ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Rutala, William A; Gergen, Maria F; Weber, David J

    2007-08-01

    Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection. To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy. The effectiveness of disinfection was determined by inoculating 10(7) colony forming units (cfu) of Pseudomonas aeruginosa at the following 3 sites on the probe: the interior lumen of the biopsy needle guide, the outside surface of the biopsy needle guide, and the interior lumen of the ultrasound probe where the needle guide passes through the transducer. Each site was investigated separately. After inoculation, the probe was immersed in 2% glutaraldehyde for 20 minutes and then assessed for the level of microbial contamination. The results demonstrated that disinfection (ie, a reduction in bacterial load of greater than 7 log(10) cfu) could be achieved if the needle guide was removed from the probe. However, if the needle guide was left in the probe channel during immersion in 2% glutaraldehyde, disinfection was not achieved (ie, the reduction was approximately 1 log(10) cfu). Recommendations for probe disinfection are provided and include disassembling the device and immersing the probe and the needle guide separately in a high-level disinfectant.

  8. Interferometric microstructured polymer optical fiber ultrasound sensor for optoacoustic endoscopic imaging in biomedical applications

    DEFF Research Database (Denmark)

    Gallego, Daniel; Sáez-Rodríguez, David; Webb, David

    2014-01-01

    to conventional piezoelectric transducers. These kind of sensors, made of biocompatible polymers, are good candidates for the sensing element in an optoacoustic endoscope because of its high sensitivity, its shape and its non-brittle and non-electric nature. The acoustic sensitivity of the intrinsic fiber optic......We report a characterization of the acoustic sensitivity of microstructured polymer optical fiber interferometric sensors at ultrasonic frequencies from 100kHz to 10MHz. The use of wide-band ultrasonic fiber optic sensors in biomedical ultrasonic and optoacoustic applications is an open alternative...... interferometric sensors depends strongly of the material which is composed of. In this work we compare experimentally the intrinsic ultrasonic sensitivities of a PMMA mPOF with other three optical fibers: a singlemode silica optical fiber, a single-mode polymer optical fiber and a multimode graded...

  9. Ultrasound Guided Needle Aspiration versus Surgical Drainage in the management of breast abscesses: a Ugandan experience

    Directory of Open Access Journals (Sweden)

    Chandika Alphonce B

    2012-01-01

    Full Text Available Abstract Background Despite breast abscess becoming less common in developed countries, it has remained one of the leading causes of morbidity in women in developing countries. A randomized controlled trial was conducted at Mulago hospital complex in Kampala Uganda to establish whether ultrasound guided needle aspiration is a feasible alternative treatment option for breast abscesses. Results A total of 65 females with breast abscess were analyzed, of these 33 patients were randomized into the ultrasound guided needle aspiration and 32 patients in the Incision and drainage arm. The mean age was 23.12, most of them were lactating (66.2%, primipararous (44.6% with peripheral abscesses (73.8% located in the upper lateral quadrant (56%.The mean breast size was 3.49 cm. The two groups were comparably in demographic characteristic and breast abscess size. Survival analysis showed no difference in breast abscess healing rate between the two groups (Log rank 0.24 df 1 and P = 0.63. Incision and drainage was found to be more costly than ultrasound guided aspiration (cost effective ratio of 2.85. Conclusion Ultrasound guided needle aspiration is therefore a feasible and cost effective treatment option for both lactating and non lactating breast abscesses with a diameter up to 5 cm by ultrasound in an immune competent patient

  10. Comparison of Ultrasound-Guided and Fluoroscopy-Assisted Antegrade Common Femoral Artery Puncture Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Slattery, Michael M.; Goh, Gerard S.; Power, Sarah; Given, Mark F.; McGrath, Frank P.; Lee, Michael J., E-mail: mlee@rcsi.ie [Beaumont Hospital, Department of Radiology (Ireland)

    2015-06-15

    PurposeTo prospectively compare the procedural time and complication rates of ultrasound-guided and fluoroscopy-assisted antegrade common femoral artery (CFA) puncture techniques.Materials and MethodsHundred consecutive patients, undergoing a vascular procedure for which an antegrade approach was deemed necessary/desirable, were randomly assigned to undergo either ultrasound-guided or fluoroscopy-assisted CFA puncture. Time taken from administration of local anaesthetic to vascular sheath insertion in the superficial femoral artery (SFA), patients’ age, body mass index (BMI), fluoroscopy radiation dose, haemostasis method and immediate complications were recorded. Mean and median values were calculated and statistically analysed with unpaired t tests.ResultsSixty-nine male and 31 female patients underwent antegrade puncture (mean age 66.7 years). The mean BMI was 25.7 for the ultrasound-guided (n = 53) and 25.3 for the fluoroscopy-assisted (n = 47) groups. The mean time taken for the ultrasound-guided puncture was 7 min 46 s and for the fluoroscopy-assisted technique was 9 min 41 s (p = 0.021). Mean fluoroscopy dose area product in the fluoroscopy group was 199 cGy cm{sup 2}. Complications included two groin haematomas in the ultrasound-guided group and two retroperitoneal haematomas and one direct SFA puncture in the fluoroscopy-assisted group.ConclusionUltrasound-guided technique is faster and safer for antegrade CFA puncture when compared to the fluoroscopic-assisted technique alone.

  11. Ultrasound guided TAP block versus ultrasound guided caudal block for pain relief in children undergoing lower abdominal surgeries

    Directory of Open Access Journals (Sweden)

    Wafaa Mohamed Alsadek

    2015-04-01

    Conclusion: TAP block and caudal block under ultrasound guidance proved to be safe with no recorded complications either intra or postoperatively. Patient and parent satisfaction was markedly observed in case of TAP block.

  12. Preoperative Navigated Transcranial Magnetic Stimulation and Tractography to Guide Endoscopic Cystoventriculostomy: A Technical Note and Case Report.

    Science.gov (United States)

    Hendrix, Philipp; Senger, Sebastian; Griessenauer, Christoph J; Simgen, Andreas; Linsler, Stefan; Oertel, Joachim

    2018-01-01

    To report a technique for endoscopic cystoventriculostomy guided by preoperative navigated transcranial magnetic stimulation (nTMS) and tractography in a patient with a large speech eloquent arachnoid cyst. A 74-year old woman presented with a seizure and subsequent persistent anomic aphasia from a progressive left-sided parietal arachnoid cyst. An endoscopic cystoventriculostomy and endoscope-assisted ventricle catheter placement were performed. Surgery was guided by preoperative nTMS and tractography to avoid eloquent language, motor, and visual pathways. Preoperative nTMS motor and language mapping were used to guide tractography of motor and language white matter tracts. The ideal locations of entry point and cystoventriculostomy as well as trajectory for stent-placement were determined preoperatively with a pseudo-3-dimensional model visualizing eloquent language, motor, and visual cortical and subcortical information. The early postoperative course was uneventful. At her 3-month follow-up visit, her language impairments had completely recovered. Additionally, magnetic resonance imaging demonstrated complete collapse of the arachnoid cyst. The combination of nTMS and tractography supports the identification of a safe trajectory for cystoventriculostomy in eloquent arachnoid cysts. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Endoscopic ultrasound as an adjunctive evaluation in patients with esophageal motor disorders subtyped by high-resolution manometry

    Science.gov (United States)

    Krishnan, Kumar; Lin, Chen-Yuan; Keswani, Rajesh; Pandolfino, John E; Kahrilas, Peter J; Komanduri, Srinadh

    2015-01-01

    Background and aims Esophageal motor disorders are a heterogenous group of conditions identified by esophageal manometry that lead to esophageal dysfunction. The aim of this study was to assess the clinical utility of endoscopic ultrasound in the further evaluation of patients with esophageal motor disorders categorized using the updated Chicago Classification. Methods We performed a retrospective, single center study of 62 patients with esophageal motor disorders categorized according to the Chicago Classification. All patients underwent standard radial endosonography to assess for extra esophageal findings or alternative explanations for esophageal outflow obstruction. Secondary outcomes included esophageal wall thickness among the different patient subsets within the Chicago Classification Key Results EUS identified 9/62 (15%) clinically relevant findings that altered patient management and explained the etiology of esophageal outflow obstruction. We further identified substantial variability in esophageal wall thickness in a proportion of patients including some with a significantly thickened non-muscular layer. Conclusions EUS findings are clinically relevant in a significant number of patients with motor disorders and can alter clinical management. Variability in esophageal wall thickness of the muscularis propria and non-muscular layers identified by EUS may also explain the observed variability in response to standard therapies for achalasia. PMID:25041229

  14. Targeted Ultrasound-Guided Perineural Hydrodissection of the Sciatic Nerve for the Treatment of Piriformis Syndrome.

    Science.gov (United States)

    Burke, Christopher J; Walter, William R; Adler, Ronald S

    2018-05-01

    Piriformis syndrome is a common cause of lumbar, gluteal, and thigh pain, frequently associated with sciatic nerve symptoms. Potential etiologies include muscle injury or chronic muscle stretching associated with gait disturbances. There is a common pathological end pathway involving hypertrophy, spasm, contracture, inflammation, and scarring of the piriformis muscle, leading to impingement of the sciatic nerve. Ultrasound-guided piriformis injections are frequently used in the treatment of these pain syndromes, with most of the published literature describing injection of the muscle. We describe a safe, effective ultrasound-guided injection technique for the treatment of piriformis syndrome using targeted sciatic perineural hydrodissection followed by therapeutic corticosteroid injection.

  15. Ultrasound guided percutaneous fine needle aspiration biopsy of the liver with focal lesion

    International Nuclear Information System (INIS)

    Ko, Gang Seok; Yang, Hyun Cheol; Park, Byoung Lan; Kim, Byoung Geun; Sohn, Jang Sihn

    1985-01-01

    The ultrasound-guided fine needle aspirations were performed in order to diagnose a suspected neoplastic or infectious disease in 52 patients with focal liver disease. Of these, neoplastic lesions were suspected in 31 patients and infectious lesions in 21 patients ultrasonically and/or clinically. The overall accuracy for both suspected malignant and infectious disease was 79% (41/52). The primary indication for fine needle aspiration was to document the presence of malignancy and to avoid a diagnostic laparotomy, and to drain hepatic abscess. Consequently we were convinced that the ultrasound-guided percutaneous fine needle aspiration biopsy in the focal liver disease is the best method for a conclusive diagnosis

  16. Septic bursitis after ultrasound-guided percutaneous treatment of rotator cuff calcific tendinopathy.

    Science.gov (United States)

    Sconfienza, Luca Maria; Randelli, Filippo; Sdao, Silvana; Sardanelli, Francesco; Randelli, Pietro

    2014-08-01

    Calcific tendinopathy of the rotator cuff is a common condition. Ultrasound-guided percutaneous aspiration is one of several options to treat this condition. The main advantages of this procedure are short duration, good outcome, and low cost. Furthermore, only minor complications have been reported in the literature, namely, vagal reactions during the procedure and mild postprocedural pain. We report the first case of septic bursitis after ultrasound-guided percutaneous treatment of calcific tendinopathy. Although this is generally considered a very safe procedure, a risk of infection should be taken into account. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  17. Ultrasound-guided hydrostatic reduction of intestinal intussusception: description of three cases

    Directory of Open Access Journals (Sweden)

    Martha Hanemann Kim

    2008-09-01

    Full Text Available With the objective of reporting the technique of ultrasound-guided hydrostatic reduction of intestinal intussusception, three cases with confirmed diagnosis of the disease submitted to reduction with this technique are described. All cases had successful reductions with no complications. One patient experienced a recurrence of the invagination eight days after treatment, which was surgically corrected. The technique of hydrostatic reversal of intestinal intussusception guided by ultrasound may be used in place of the conventional barium enema, since it is a minimally invasive and safe method, with high rates of success and few complications.

  18. Ultrasound-Guided Single-Injection Infraclavicular Block Versus Ultrasound-Guided Double-Injection Axillary Block: A Noninferiority Randomized Controlled Trial.

    Science.gov (United States)

    Boivin, Ariane; Nadeau, Marie-Josée; Dion, Nicolas; Lévesque, Simon; Nicole, Pierre C; Turgeon, Alexis F

    2016-01-01

    Single-injection ultrasound-guided infraclavicular block is a simple, reliable, and effective technique. A simplified double-injection ultrasound-guided axillary block technique with a high success rate recently has been described. It has the advantage of being performed in a superficial and compressible location, with a potentially improved safety profile. However, its effectiveness in comparison with single-injection infraclavicular block has not been established. We hypothesized that the double-injection ultrasound-guided axillary block would show rates of complete sensory block at 30 minutes noninferior to the single-injection ultrasound-guided infraclavicular block. After approval by our research ethics committee and written informed consent, adults undergoing distal upper arm surgery were randomized to either group I, ultrasound-guided single-injection infraclavicular block, or group A, ultrasound-guided double-injection axillary block. In group I, 30 mL of 1.5% mepivacaine was injected posterior to the axillary artery. In group A, 25 mL of 1.5% mepivacaine was injected posteromedial to the axillary artery, after which 5 mL was injected around the musculocutaneous nerve. Primary outcome was the rate of complete sensory block at 30 minutes. Secondary outcomes were the onset of sensory and motor blocks, surgical success rates, performance times, and incidence of complications. All outcomes were assessed by a blinded investigator. The noninferiority of the double-injection ultrasound-guided axillary block was considered if the limits of the 90% confidence intervals (CIs) were within a 10% margin of the rate of complete sensory block of the infraclavicular block. At 30 minutes, the rate of complete sensory block was 79% in group A (90% CI, 71%-85%) compared with 91% in group I (90% CI, 85%-95%); the upper limit of CI of group A is thus included in the established noninferiority margin of 10%. The rate of complete sensory block was lower in group A (proportion

  19. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  20. The role of ultrasound-guided triamcinolone injection in the treatment of de Quervain's disease: treatment and a diagnostic tool?

    NARCIS (Netherlands)

    Hajder, E.; de Jonge, M. C.; van der Horst, C. M. A. M.; Obdeijn, M. C.

    2013-01-01

    The purpose of this study was to describe the technique and usefulness of ultrasound-guided intrasheath injection of triamcinolone in the treatment of de Quervain's disease (dQD). Our study was retrospective in design. Seventy-one wrists of 62 patients who were treated with an ultrasound-guided

  1. An estimation of the minimum effective anesthetic volume of 2% lidocaine in ultrasound-guided axillary brachial plexus block.

    LENUS (Irish Health Repository)

    O'Donnell, Brian D

    2009-07-01

    Ultrasound guidance facilitates precise needle and injectate placement, increasing axillary block success rates, reducing onset times, and permitting local anesthetic dose reduction. The minimum effective volume of local anesthetic in ultrasound-guided axillary brachial plexus block is unknown. The authors performed a study to estimate the minimum effective anesthetic volume of 2% lidocaine with 1:200,000 epinephrine (2% LidoEpi) in ultrasound-guided axillary brachial plexus block.

  2. Yield and Safety Profile of Ultrasound Guided Fine Needle Aspiration Cytology (FNAC) of Lymph Nodes

    International Nuclear Information System (INIS)

    Sattar, A.; Wahab, S.; Javed, A.; Shamim, S. H.

    2016-01-01

    Objective: To determine the re-biopsy rate, positive yield and safety profile of ultrasound guided fine needle aspiration cytology (FNAC) in cervical lymph nodes in terms of its complications and repeat procedures. Study Design: An analytical study. Place and Duration of Study: Department of Vascular and Interventional Radiology, Dow University Hospital, Dow University of Health Sciences, Karachi, from June to December 2013. Methodology: Eighty neck swellings, which were found to be lymph nodes on ultrasound, underwent ultrasound guided FNAC, from outpatients. Lymph nodes which were included in the study were those that were not easily palpable, located near major blood vessels, where patient refused of direct palpation and wanted image guided FNAC, those directly sent by physician for image guided FNAC and where blind biopsy remained inconclusive. Patients who refused on explanation or did not give consent were excluded. Complications and repeat biopsy were noted. Result: This study consisted of 80 cases, of which 51 cases (63.75 percentage) were female and 29 cases (36.25 percentage) were male. Repeat biopsy was required in 1 case (1.6 percentage). There were no procedure-related complications. A total of 44 cases (55 percentage) revealed evidence suggesting or confirming the existence of tuberculosis. Rest of the others showed other benign lesions, reactive lymphadenopathy and malignancy. Conclusion: Ultrasound guided FNAC is a safe procedure with low re-biopsy rate that aids diagnosis. The predominant cause of cervical lymphadenopathy in this study was tuberculous lymphadenitis. (author)

  3. Evaluating imaging-pathology concordance and discordance after ultrasound-guided breast biopsy

    Science.gov (United States)

    2018-01-01

    Ultrasound (US)-guided breast biopsy has become the main method for diagnosing breast pathology, and it has a high diagnostic accuracy, approaching that of open surgical biopsy. However, methods for confirming adequate lesion retrieval after US-guided biopsy are relatively limited and false-negative results are unavoidable. Determining imaging-pathology concordance after US-guided biopsy is essential for validating the biopsy result and providing appropriate management. In this review article, we briefly present the results of US-guided breast biopsy; describe general aspects to consider when establishing imaging-pathology concordance; and review the various categories of imaging-pathology correlations and corresponding management strategies. PMID:29169231

  4. Role of Ultrasound Guided Biopsy of Thoracic Lesions | Elameen ...

    African Journals Online (AJOL)

    Objective: This prospective study is to evaluate and enhance the role of ultrasound in biopsy guidance of thoracic lesions. Methods: 55 patients were subjected for fine needle aspiration (FNA) and/or core needle biopsy (CNB) from peripheral chest lesions in Ribat University Hospital during the period from April 2011 and ...

  5. Transperineal seed-implantation guided by biplanar transrectal ultrasound

    DEFF Research Database (Denmark)

    Holm, Hans Henrik; Torp-Pedersen, S; Myschetzky, P

    1990-01-01

    A new method for precise transperineal placement of therapeutic sources in prostatic cancer is described. The method is a modification of the technique described in 1983 by Holm and coworkers. Insertion of needles is monitored by transverse as well as longitudinal transrectal ultrasound....

  6. Ultrasound-guided peripheral nerve blocks: what are the benefits?

    DEFF Research Database (Denmark)

    Nielsen, Zbigniew Jerzy Koscielniak

    2008-01-01

    with the MESH terms 'nerve block' and 'ultrasonography'. The following limits were applied: studies with abstracts, only in humans, published in core clinical journals. Trial type: meta-analysis, randomized-controlled trial and clinical trial. RESULTS: When peripheral nerves are adequately imaged by ultrasound...

  7. Variables determining the success of ultrasound-guided hydrostatic ...

    African Journals Online (AJOL)

    Department of Pediatric Surgery, Faculty of Medicine, Tanta University Hospitals,. Tanta, Egypt ... Ultrasound was performed using warm normal saline 0.9% through a Foley's catheter that was passed into the rectum. Irritable infants received slow intrave- nous diazepam ... duplication cyst) and resection (13.6%) Table 4.

  8. Ultrasound-guided cryoablation of breast fibroadenoma: a pilot trial.

    Science.gov (United States)

    Golatta, Michael; Harcos, Aba; Pavlista, David; Danes, Jan; Klein, Rafi; Simovich, Paola; Gruber, Ines; Hahn, Markus

    2015-06-01

    The aim of the study was to evaluate cryoablation (CA) under ultrasound guidance in the office setting with liquid nitrogen system for patients with fibroadenoma (FA). For this prospective multicenter trial, an office-based cryosurgical system was used to treat histological confirmed benign FA with a maximum dimension of 3 cm. Sixty CA procedures were performed under ultrasound guidance. A freeze-thaw-freeze treatment cycle was performed according to the size of the FA. During the CA procedure continuous ultrasound monitoring was performed, verifying engulfment of the FA. Patients attended four follow-up visits at 1 week, 3, 6 months and 1 year and underwent ultrasound, physical examination and photography. Data were collected and analyzed in 60 cases. 59 of 60 FA (98 %) were fully engulfed by the ice ball. No serious adverse events occurred related to the IceSense3 system. At the 1-year follow-up, the FAs were gone in 93% of the cases. Prior to CA procedure, 76% of the FAs were palpable. Afterwards in some cases (22%), a scar/cryo lesion was palpable. 28% of the patients reported pain, described as mild or moderate, compared to 2% after 1 year. Cosmetic results at 12 months follow-up were reported as good or excellent in 100% by physician and in 97% by patients. The cryodestruction of the FA using liquid nitrogen system proved functional and safe, while showing meaningful reduction in volume, palpability, pain and cosmetic satisfying outcomes.

  9. Transperineal seed-implantation guided by biplanar transrectal ultrasound

    International Nuclear Information System (INIS)

    Holm, H.H.; Torp-Pedersen, S.; Myschetzky, P.

    1990-01-01

    A new method for precise transperineal placement of therapeutic sources in prostatic cancer is described. The method is a modification of the technique described in 1983 by Holm and coworkers. Insertion of needles is monitored by transverse as well as longitudinal transrectal ultrasound

  10. Photodynamic therapy (PDT) with endoscopic ultrasound for the treatment of esophageal cancer

    Science.gov (United States)

    Woodward, Timothy A.; Wolfsen, Herbert C.

    2000-05-01

    In 1995, PDT was approved for palliative use in patients with esophageal cancer. We report our experience using PDT to treat esophageal cancer patients previously treated with combination chemotherapy and radiation therapy. In our series, nine patients referred for PDT with persistent esophageal cancer after chemo-radiation therapy. We found: (1) All patients were men with a mean age of 63 years and eight out of nine had adenocarcinoma with Barrett's esophagus; (2) All patients required endoscopic dilation after PDT; (3) At a mean follow up of 4 months, two T2N0 patients had no demonstrable tumor and all three T3N0 patients had greater than 50% tumor reduction (the partially responsive T3N0 patients will be offered repeat PDT); (4) Patients with metastatic disease (T3N1 or M1) had effective dysphagia palliation. Thus, PDT is safe and effective in ablating all or most tumor in patients with persistent esophageal cancer after chemotherapy and radiation therapy.

  11. Ultrasound/Magnetic Resonance Image Fusion Guided Lumbosacral Plexus Block – A Clinical Study

    DEFF Research Database (Denmark)

    Strid, JM; Pedersen, Erik Morre; Søballe, Kjeld

    2014-01-01

    in a double-blinded randomized controlled trial with crossover design. MR datasets will be acquired and uploaded in an advanced US system (Epiq7, Phillips, Amsterdam, Netherlands). All volunteers will receive SSPS blocks with lidocaine added gadolinium contrast guided by US/MR image fusion and by US one week......Background and aims Ultrasound (US) guided lumbosacral plexus block (Supra Sacral Parallel Shift [SSPS]) offers an alternative to general anaesthesia and perioperative analgesia for hip surgery.1 The complex anatomy of the lumbosacral region hampers the accuracy of the block, but it may be improved...... by guidance of US and magnetic resonance (MR) image fusion and real-time 3D electronic needle tip tracking.2 We aim to estimate the effect and the distribution of lidocaine after SSPS guided by US/MR image fusion compared to SSPS guided by ultrasound. Methods Twenty-four healthy volunteers will be included...

  12. Neurologic Outcomes After Low-Volume, Ultrasound-Guided Interscalene Block and Ambulatory Shoulder Surgery.

    Science.gov (United States)

    Rajpal, Gaurav; Winger, Daniel G; Cortazzo, Megan; Kentor, Michael L; Orebaugh, Steven L

    2016-01-01

    Postoperative neurologic symptoms after interscalene block and shoulder surgery have been reported to be relatively frequent. Reports of such symptoms after ultrasound-guided block have been variable. We evaluated 300 patients for neurologic symptoms after low-volume, ultrasound-guided interscalene block and arthroscopic shoulder surgery. Patients underwent ultrasound-guided interscalene block with 16 to 20 mL of 0.5% bupivacaine or a mix of 0.2% bupivacaine/1.2% mepivacaine solution, followed by propofol/ketamine sedation for ambulatory arthroscopic shoulder surgery. Patients were called at 10 days for evaluation of neurologic symptoms, and those with persistent symptoms were called again at 30 days, at which point neurologic evaluation was initiated. Details of patient demographics and block characteristics were collected to assess any association with persistent neurologic symptoms. Six of 300 patients reported symptoms at 10 days (2%), with one of these patients having persistent symptoms at 30 days (0.3%). This was significantly lower than rates of neurologic symptoms reported in preultrasound investigations with focused neurologic follow-up and similar to other studies performed in the ultrasound era. There was a modest correlation between the number of needle redirections during the block procedure and the presence of postoperative neurologic symptoms. Ultrasound guidance of interscalene block with 16- to 20-mL volumes of local anesthetic solution results in a lower frequency of postoperative neurologic symptoms at 10 and 30 days as compared with investigations in the preultrasound period.

  13. Ultrasound-guided percutaneous cholecysto-cholangiography for the exclusion of biliary atresia in infants

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Kyung Min; Ryeom, Hun Kyu; Choe, Byung Ho; Kim, Kap Cheol; Kim, Jong Yeol; Lee, Jong Min; Kim, Hye Jeong; Lee, Hee Jung [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2006-08-15

    The aim of this study is to determine the feasibility and effectiveness of performing an ultrasound-guided percutaneous cholecysto-cholangiogram (PCC) for excluding biliary atresia as the cause of neonatal jaundice. Between Oct. 2003 and Feb. 2005, six ultrasound-guided PCC procedures were performed to five jaundiced infants (4 females and 1 male; mean age: 60 days old) for whom possibility of biliary atresia could not be ruled out by the DISIDA scan as the cause of their neonatal jaundice. Gallbladder puncture was performed under ultrasound guidance with a 23-gauge needle. Contrast material injection during fluoroscopic examination was performed after dilatation of the gallbladder lumen with normal saline under ultrasound guidance. The criteria used for excluding biliary atresia were complete visualization of the extrahepatic biliary trees and/or contrast excretion into the duodenum. The complications and final diagnosis was assessed according to the clinical and laboratory findings. The procedures were successful in all the patients without any complication. Biliary atresia could be ruled out in all the patients. The final diagnosis was neonatal cytomegalovirus hepatitis in two patients, total parenteral nutrition-associated cholestasis in two patients, and combined cytomegalovirus hepatitis and total parenteral nutrition-associated cholestasis in one patient. Ultrasound-guided PCC is a feasible and effective method for the early definitive exclusion of biliary atresia as the cause of neonatal jaundice. By the technique of injecting normal saline before contrast injection, PCC can be done even in a totally collapsed or very small gallbladder.

  14. Ultrasound-guided percutaneous cholecysto-cholangiography for the exclusion of biliary atresia in infants

    International Nuclear Information System (INIS)

    Shin, Kyung Min; Ryeom, Hun Kyu; Choe, Byung Ho; Kim, Kap Cheol; Kim, Jong Yeol; Lee, Jong Min; Kim, Hye Jeong; Lee, Hee Jung

    2006-01-01

    The aim of this study is to determine the feasibility and effectiveness of performing an ultrasound-guided percutaneous cholecysto-cholangiogram (PCC) for excluding biliary atresia as the cause of neonatal jaundice. Between Oct. 2003 and Feb. 2005, six ultrasound-guided PCC procedures were performed to five jaundiced infants (4 females and 1 male; mean age: 60 days old) for whom possibility of biliary atresia could not be ruled out by the DISIDA scan as the cause of their neonatal jaundice. Gallbladder puncture was performed under ultrasound guidance with a 23-gauge needle. Contrast material injection during fluoroscopic examination was performed after dilatation of the gallbladder lumen with normal saline under ultrasound guidance. The criteria used for excluding biliary atresia were complete visualization of the extrahepatic biliary trees and/or contrast excretion into the duodenum. The complications and final diagnosis was assessed according to the clinical and laboratory findings. The procedures were successful in all the patients without any complication. Biliary atresia could be ruled out in all the patients. The final diagnosis was neonatal cytomegalovirus hepatitis in two patients, total parenteral nutrition-associated cholestasis in two patients, and combined cytomegalovirus hepatitis and total parenteral nutrition-associated cholestasis in one patient. Ultrasound-guided PCC is a feasible and effective method for the early definitive exclusion of biliary atresia as the cause of neonatal jaundice. By the technique of injecting normal saline before contrast injection, PCC can be done even in a totally collapsed or very small gallbladder

  15. Subacute posteromedial impingement of the ankle in athletes: MR imaging evaluation and ultrasound guided therapy

    International Nuclear Information System (INIS)

    Messiou, Christina; Robinson, Philip; O'Connor, Philip J.; Grainger, Andrew

    2006-01-01

    To describe the use of MR imaging and efficacy of ultrasound-guided steroid injection in the diagnosis and management of athletes with clinical posteromedial impingement of the ankle. A retrospective analysis of imaging findings on MR was undertaken in nine elite athletes with clinical posteromedial ankle impingement. MR studies from six professional athletes with posterolateral pain were also reviewed as an imaging control group. The two reviewing radiologists were blinded to the clinical details and the proportion of control and study subjects. The nine study athletes also underwent diagnostic ultrasound and ultrasound-guided injection of steroid and anaesthetic into the posteromedial capsular abnormality. Follow-up was by telephone interview. Posteromedial capsular thickening was seen only in athletes with posteromedial impingement (7/9). Posteromedial synovitis was present in all athletes with posteromedial impingement; however, posterior and posterolateral synovitis was also seen in these athletes. Mild posteromedial synovitis was present in two control athletes. Ultrasound identified abnormal posteromedial soft tissue thickening deep to tibialis posterior between the medial malleolus and talus in all nine athletes. After injection all athletes returned to their previous level of sport, with eight of the nine not experiencing any residual or recurrent symptoms. If MR imaging excludes significant coexistent abnormality, ultrasound can localise posteromedial soft tissue abnormality and guide injection therapy, allowing return to athletic activity without surgical intervention. (orig.)

  16. Intravascular ultrasound guided directional atherectomy versus directional atherectomy guided by angiography for the treatment of femoropopliteal in-stent restenosis

    Science.gov (United States)

    Krishnan, Prakash; Tarricone, Arthur; K-Raman, Purushothaman; Majeed, Farhan; Kapur, Vishal; Gujja, Karthik; Wiley, Jose; Vasquez, Miguel; Lascano, Rheoneil A.; Quiles, Katherine G.; Distin, Tashanne; Fontenelle, Ran; Atallah-Lajam, Farah; Kini, Annapoorna; Sharma, Samin

    2017-01-01

    Background: The aim of this study was to compare 1-year outcomes for patients with femoropopliteal in-stent restenosis using directional atherectomy guided by intravascular ultrasound (IVUS) versus directional atherectomy guided by angiography. Methods and results: This was a retrospective analysis for patients with femoropopliteal in-stent restenosis treated with IVUS-guided directional atherectomy versus directional atherectomy guided by angiography from a single center between March 2012 and February 2016. Clinically driven target lesion revascularization was the primary endpoint and was evaluated through medical chart review as well as phone call follow up. Conclusions: Directional atherectomy guided by IVUS reduces clinically driven target lesion revascularization for patients with femoropopliteal in-stent restenosis. PMID:29265002

  17. Role of endoscopic ultrasound in the diagnosis and staging of pancreatic cancer

    DEFF Research Database (Denmark)

    Saftoiu, Adrian; Vilmann, Peter

    2009-01-01

    . The introduction of EUS-guided fine needle aspiration allows a preoperative diagnosis in patients with resectable cancer, as well as a confirmation of diagnosis before chemoradiotherapy for those that are not. This comprehensive review highlighted the diagnostic capabilities of EUS including the newest refinements...

  18. Ultrasound-guided procedures around the wrist and hand: How to do

    International Nuclear Information System (INIS)

    Orlandi, Davide; Corazza, Angelo; Silvestri, Enzo; Serafini, Giovanni; Savarino, Edoardo Vincenzo; Garlaschi, Giacomo; Mauri, Giovanni; Cimmino, Marco Amedeo; Sconfienza, Luca Maria

    2014-01-01

    Ultrasound has emerged as a low-cost, radiation-free and effective imaging technique to detect joint abnormalities and to guide percutaneous procedures. Being superficial, wrist and hand tendons and joints represent a good target to perform such procedures using ultrasound guidance. This kind of approach allows for a clear and real-time visualization of the needles during their whole path. In this setting, the knowledge of technical aspects and tips is essential to act in the most accurate way on target tissues that can be as small as a few millimetres. The aim of this review is to summarize the local treatments of inflammatory and degenerative disease described in literature (such as treatment of De Quervain's tenosynovitis, trigger finger, trapezio-metacarpal joint osteoarthritis, etc.), emphasizing precautions and tricks based on day-by-day experience that may help to improve the outcome of percutaneous ultrasound-guided procedures around the wrist and hand

  19. Ultrasound-Guided Femoral Nerve Block to Facilitate the Closed Reduction of a Dislocated Hip Prosthesis

    Directory of Open Access Journals (Sweden)

    Edward Carlin

    2017-10-01

    Full Text Available Prosthetic hip dislocation is a common but unfortunate complication in patients who have undergone total hip arthroplasty. Successful closed reduction in the emergency department leads to a reduced length of stay and rate of hospitalization. 1, 2 The use of regional anesthesia by femoral nerve block represents a novel approach for controlling pain in patients with hip pathologies. 3 Ultrasound-guided approaches have been used with great success for controlling pain in patients with hip fractures. 4, 5 Here we report the case of a 90-year-old male who presented with a dislocated hip prosthesis, which was subsequently corrected with closed reduction following delivery of regional anesthesia to the femoral nerve under ultrasound guidance. To our knowledge, this represents the first reported use of an ultrasound-guided femoral nerve block to facilitate closed reduction of a dislocated prosthetic hip, and highlights a novel approach that avoids the use of procedural sedation in an elderly patient.

  20. Ultrasound-guided procedures around the wrist and hand: How to do

    Energy Technology Data Exchange (ETDEWEB)

    Orlandi, Davide; Corazza, Angelo [Scuola di Specializzazione in Radiodiagnostica, Università degli Studi di Genova, Via L.B. Alberti 4, 16132 Genova (Italy); Silvestri, Enzo [Diagnostica per Immagini, Ospedale Evangelico Internazionale, Corso Solferino 29A, 16100 Genova (Italy); Serafini, Giovanni [Dipartimento di Diagnostica per Immagini, Ospedale Santa Corona, Via XXV Aprile 38, 17037 Pietra Ligure, Savona (Italy); Savarino, Edoardo Vincenzo [Dipartimento di Scienze Chirurgiche, Oncologiche e Gastroenterologiche, Università degli Studi di Padova, Via Giustiniani, Padova (Italy); Garlaschi, Giacomo [Dipartimento di Scienze per la Salute, Università degli Studi di Genova, Via L.B. Alberti 4, 16132 Genova (Italy); Mauri, Giovanni [Servizio di Radiologia, IRCCS Policlinico San Donato, Piazza Malan 2, San Donato Milanese, Milano (Italy); Cimmino, Marco Amedeo [Dipartimento di Medicina Interna, Università degli Studi di Genova, Via L.B. Alberti 4, 16132 Genova (Italy); Sconfienza, Luca Maria, E-mail: io@lucasconfienza.it [Servizio di Radiologia, IRCCS Policlinico San Donato, Piazza Malan 2, San Donato Milanese, Milano (Italy); Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Piazza Malan 2, San Donato Milanese, Milano (Italy)

    2014-07-15

    Ultrasound has emerged as a low-cost, radiation-free and effective imaging technique to detect joint abnormalities and to guide percutaneous procedures. Being superficial, wrist and hand tendons and joints represent a good target to perform such procedures using ultrasound guidance. This kind of approach allows for a clear and real-time visualization of the needles during their whole path. In this setting, the knowledge of technical aspects and tips is essential to act in the most accurate way on target tissues that can be as small as a few millimetres. The aim of this review is to summarize the local treatments of inflammatory and degenerative disease described in literature (such as treatment of De Quervain's tenosynovitis, trigger finger, trapezio-metacarpal joint osteoarthritis, etc.), emphasizing precautions and tricks based on day-by-day experience that may help to improve the outcome of percutaneous ultrasound-guided procedures around the wrist and hand.

  1. Efficacy of Ablation Therapy for Secondary Hyperparathyroidism by Ultrasound Guided Percutaneous Thermoablation.

    Science.gov (United States)

    Zhao, Junfeng; Qian, Linxue; Zu, Yuan; Wei, Ying; Hu, Xiangdong

    2016-05-01

    The objective of this study was to explore the value of ultrasound-guided percutaneous microwave thermoablation to treat secondary hyperparathyroidism (SHPT). One hundred and thirty-eight parathyroid glands from 56 patients with SHPT were ablated in this study. All the parathyroid glands were evaluated by real-time contrast-enhanced ultrasound before, during and after ablation. Changes in serum parathyroid hormone (sPTH) levels were measured before treatment and at 1 h, 1 wk, 1 mo and 6 mo after thermoablation treatment. All 56 cases had a 1-mo follow-up, and 34 cases had a 6-mo follow-up. The sPTH level of the 54 cases 1 mo after ablation was significantly lower than that before (p 0.05). Ultrasound-guided percutaneous microwave thermoablation is a feasible and effective non-surgical alternative treatment for SHPT patients. Copyright © 2016. Published by Elsevier Inc.

  2. Feasibility of contrast-enhanced ultrasound-guided biopsy of sentinel lymph nodes in dogs.

    Science.gov (United States)

    Gelb, Hylton R; Freeman, Lynetta J; Rohleder, Jacob J; Snyder, Paul W

    2010-01-01

    Our goal was to develop and validate a technique to identify the sentinel lymph nodes of the mammary glands of healthy dogs with contrast-enhanced ultrasound, and evaluate the feasibility of obtaining representative samples of a sentinel lymph node under ultrasound guidance using a new biopsy device. Three healthy intact female adult hounds were anesthetized and each received an injection of octafluoropropane-filled lipid microspheres and a separate subcutaneous injection of methylene blue dye around a mammary gland. Ultrasound was then used to follow the contrast agent through the lymphatic channel to the sentinel lymph node. Lymph node biopsy was performed under ultrasound guidance, followed by an excisional biopsy of the lymph nodes and a regional mastectomy procedure. Excised tissues were submitted for histopathologic examination and evaluated as to whether they were representative of the node. The ultrasound contrast agent was easily visualized with ultrasound leading up to the sentinel lymph nodes. Eight normal lymph nodes (two inguinal, one axillary in two dogs; two inguinal in one dog) were identified and biopsied. Lymphoid tissue was obtained from all biopsy specimens. Samples from four of eight lymph nodes contained both cortical and medullary lymphoid tissue. Contrast-enhanced ultrasound can be successfully used to image and guide minimally invasive biopsy of the normal sentinel lymph nodes draining the mammary glands in healthy dogs. Further work is needed to evaluate whether this technique may be applicable in patients with breast cancer or other conditions warranting evaluation of sentinel lymph nodes in animals.

  3. Ultrasound guided aspiration of breast abscess as an alternative to surgical incision and drainage

    International Nuclear Information System (INIS)

    Naper, M.A.; Shaikh, M.S.; Dholia, K.R.

    2017-01-01

    To evaluate the outcome and assess the success rate of ultrasound guided aspiration of breast abscess as an alternative to surgical incision and drainage. Methodology: A prospective descriptive study was carried out at Department of Surgery, Chandka Medical College Hospital, Larkana, Pakistan, from January 2015 to December 2015. A total of 111 patients of breast abscess who underwent ultrasound guided aspiration without anesthesias with oral antibiotic cover were studied. Females with breast abscess within seven days, and the abscess size was <3cm were included in the study. Males, antibioma and inflammatory carcinoma were excluded from the study. Outcome of success or failure was observed within two weeks and recorded. Results: Out of 111 patients, 68.46% were lactating and 31.53% were non-lactating women, with ages ranging from 18 to 60 years (mean 36.5 years). The successful rate with complete resolution after ultrasound guided aspiration was observed in 94.5%. 80.82% responded after single aspiration, 12.38% after two times aspiration, and 6.66% after multiple aspirations, while 5.4% of patients required incision and drainage. Conclusion: Ultrasound guided aspiration of breast abscess is an effective treatment option with a diameter of <3cm, which can be recommended as a routine outpatient procedure. (author)

  4. Ultrasound-Guided Bipolar Umbilical Cord Occlusion in Complicated Monochorionic Pregnancies

    DEFF Research Database (Denmark)

    Schou, Katrine V; Jensen, Lisa N; Jørgensen, Connie

    2017-01-01

    INTRODUCTION: Ultrasound-guided bipolar umbilical cord occlusion (UCO) is used in complicated monochorionic multiple pregnancies in Denmark. The aim of this study was to assess a learning curve in the procedure of UCO. MATERIALS AND METHODS: One hundred and two monochorionic pregnancies treated...

  5. Distal infrared thermography and skin temperature after ultrasound-guided interscalene brachial plexus block

    DEFF Research Database (Denmark)

    Asghar, Semera; Bjerregaard, Lars S; Lundstrøm, Lars H

    2014-01-01

    thermographic imaging of the hand before and at 1 min intervals for 30 min after an ultrasound-guided IBPB with 20 ml ropivacaine 7.5 mg ml. Cooling of both hands was performed to standardise measurements. MAIN OUTCOME MEASURES: Thermographic changes in skin temperature on the dorsum of the hand. RESULTS: Forty...

  6. A clinical assessment tool for ultrasound-guided axillary brachial plexus block.

    LENUS (Irish Health Repository)

    Sultan, S F

    2012-05-01

    Competency in anesthesia traditionally has been determined subjectively in practice. Optimal training in procedural skills requires valid and reliable forms of assessment. The objective was to examine a procedure-specific clinical assessment tool for ultrasound-guided axillary brachial plexus block for inter-rater reliability and construct validity in a clinical setting.

  7. Efficacy of a single ultrasound-guided injection for the treatment of hip osteoarthritis.

    LENUS (Irish Health Repository)

    Atchia, Ismaël

    2011-01-01

    Intra-articular injection is effective for osteoarthritis, but the best single injection strategy is not known, nor are there established predictors of response. The objectives of this study were to assess and predict response to a single ultrasound-guided injection in moderate to severe hip osteoarthritis.

  8. Ultrasound-guided lateral infraclavicular block evaluated by infrared thermography and distal skin temperature

    DEFF Research Database (Denmark)

    Asghar, Semera; Lundstrøm, Lars Hyldborg; Bjerregaard, Lars Stryhn

    2014-01-01

    of the 2nd and 5th digits. METHODS: We performed an ultrasound-guided lateral infraclavicular block in 45 patients undergoing upper limb surgery. The contralateral hand served as control and we obtained infrared thermographic images of both hands before the block and during the following 30 min. We defined...

  9. Update on the role of ultrasound guided radiofrequency ablation for thyroid nodule treatment

    DEFF Research Database (Denmark)

    Radzina, Maija; Cantisani, Vito; Rauda, Madara

    2017-01-01

    Thyroid nodules can be frequently detected in general population, most of them are benign, however malignant cases are rising in the past decades. Ultrasound (US) is the most common imaging modality to assess thyroid nodular lesions, plan patient work-up and guide minimally invasive treatment...

  10. Feasibility of ultrasound-guided intraarticular contrast injection for MR arthrography

    International Nuclear Information System (INIS)

    Baek, Soo Jin; Lee, Jong Min; Kang, Duck Sick

    2005-01-01

    To assess the feasibility of ultrasound-guided intraarticular contrast injection using the posterior approach for MR arthrography. Between June 2002 and October 2004, 132 patients (29 female, 103 male: mean age, 33.6 years) underwent ultrasound-guided intraarticular contrast media injection (40 ml saline + 10 ml 2% lidocaine + 0.2 ml gadopentetate dimeglumine + 0.4 ml epinephrine) for MR arthrography. The patients were classified into four groups, viz. the no leakage group, the minor leakage with successful intraarticular injection group, the major leakage with unsuccessful intraarticular injection group, and the injection failure group. The 'no leakage' and 'minor leakage' groups were considered to be technical successes, while the 'major leakage' and 'injection failure' groups were regarded as technical failures. The technical success rate of ultrasound-guided intraarticular contrast injection using the posterior approach for MR Arthrography was 99.2% (131/132 patients) and one patients 0.7% (1/132 patients) was included in the 'major leakage' group. Ultrasound-guided intraarticular contrast injection using the posterior approach for MR arthrography was feasible with a high success rate

  11. Perioperative ultrasound-guided wire marking of calcific deposits in calcifying tendinitis of the rotator cuff.

    Science.gov (United States)

    Sigg, Andreas; Draws, Detlev; Stamm, Axel; Pfeiffer, Michael

    2011-03-01

    The identification of a calcific deposit in the rotator cuff can often cause difficulties. A new technique is described to identify the calcific deposit perioperatively with a ultrasound-guided wire. The technique allows a safe direct marking of calcific deposits making the procedure faster especially in difficult cases.

  12. Analgesic effect of ultrasound-guided transversus abdominis plane block after total abdominal hysterectomy

    DEFF Research Database (Denmark)

    Røjskjaer, Jesper O; Gade, Erik; Kiel, Louise B

    2015-01-01

    OBJECTIVE: To assess the effect of bilateral ultrasound-guided transversus abdominis plane block with ropivacaine compared with placebo as part of a multimodal analgesic regimen. DESIGN: A randomized, double-blind, placebo-controlled trial following the CONSORT criteria. SETTING: Hvidovre Univers...

  13. Value of Artisanal Simulators to Train Veterinary Students in Performing Invasive Ultrasound-Guided Procedures

    Science.gov (United States)

    Hage, Maria Cristina F. N. S.; Massaferro, Ana Beatriz; Lopes, Érika Rondon; Beraldo, Carolina Mariano; Daniel, Jéssika

    2016-01-01

    Pericardial effusion can lead to cardiac tamponade, which endangers an animal's life. Ultrasound-guided pericardiocentesis is used to remove abnormal liquid; however, it requires technical expertise. In veterinary medical education, the opportunity to teach this procedure to save lives during emergencies is rare; therefore, simulators are…

  14. Safety and Efficacy of Ultrasound-Guided Fiducial Marker Implantation for CyberKnife Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Hyun; Hong, Seong; Sook; Kim, Jung Hoon; Park, Hyun Jeong; Chang, Yun Woo; Chang, A Ram [Soonchunhyang University Seoul Hospital, Seoul (Korea, Republic of); Kwon, Seok Beom [Hallym University College of Medicine, Chuncheon (Korea, Republic of)

    2012-06-15

    To evaluate the safety and technical success rate of an ultrasound-guided fiducial marker implantation in preparation for CyberKnife radiation therapy. We retrospectively reviewed 270 percutaneous ultrasound-guided fiducial marker implantations in 77 patients, which were performed from June 2008 through March 2011. Of 270 implantations, 104 were implanted in metastatic lymph nodes, 96 were in the liver, 39 were in the pancreas, and 31 were in the prostate. During and after the implantation, major and minor procedure-related complications were documented. We defined technical success as the implantation enabling adequate treatment planning and CT simulation. The major and minor complication rates were 1% and 21%, respectively. One patient who had an implantation in the liver suffered severe abdominal pain, biloma, and pleural effusion, which were considered as major complication. Abdominal pain was the most common complication in 11 patients (14%). Among nine patients who had markers inserted in the prostate, one had transient hematuria for less than 24 hours, and the other experienced transient voiding difficulty. Of the 270 implantations, 261 were successful (97%). The reasons for unsuccessful implantations included migration of fiducial markers (five implantations, 2%) and failure to discriminate the fiducial markers (three implantations, 1%). Among the unsuccessful implantation cases, six patients required additional procedures (8%). The symptomatic complications following ultrasound-guided percutaneous implantation of fiducial markers are relatively low. However, careful consideration of the relatively higher rate of migration and discrimination failure is needed when performing ultrasound-guided percutaneous implantations of fiducial markers.

  15. Ultrasound guided double injection of blood into cisterna magna: a rabbit model for treatment of cerebral vasospasm.

    Science.gov (United States)

    Chen, Yongchao; Zhu, Youzhi; Zhang, Yu; Zhang, Zixuan; Lian, Juan; Luo, Fucheng; Deng, Xuefei; Wong, Kelvin K L

    2016-02-06

    Double injection of blood into cisterna magna using a rabbit model results in cerebral vasospasm. An unacceptably high mortality rate tends to limit the application of model. Ultrasound guided puncture can provide real-time imaging guidance for operation. The aim of this paper is to establish a safe and effective rabbit model of cerebral vasospasm after subarachnoid hemorrhage with the assistance of ultrasound medical imaging. A total of 160 New Zealand white rabbits were randomly divided into four groups of 40 each: (1) manual control group, (2) manual model group, (3) ultrasound guided control group, and (4) ultrasound guided model group. The subarachnoid hemorrhage was intentionally caused by double injection of blood into their cisterna magna. Then, basilar artery diameters were measured using magnetic resonance angiography before modeling and 5 days after modeling. The depth of needle entering into cisterna magna was determined during the process of ultrasound guided puncture. The mortality rates in manual control group and model group were 15 and 23 %, respectively. No rabbits were sacrificed in those two ultrasound guided groups. We found that the mortality rate in ultrasound guided groups decreased significantly compared to manual groups. Compared with diameters before modeling, the basilar artery diameters after modeling were significantly lower in manual and ultrasound guided model groups. The vasospasm aggravated and the proportion of severe vasospasms was greater in ultrasound guided model group than that of manual group. In manual model group, no vasospasm was found in 8 % of rabbits. The ultrasound guided double injection of blood into cisterna magna is a safe and effective rabbit model for treatment of cerebral vasospasm.

  16. Diagnostic Utility of Endoscopic Retrograde Cholangiography/Intraductal Ultrasound (ERC/IDUS) in Distinguishing Malignant from Benign Bile Duct Obstruction.

    Science.gov (United States)

    Chen, Lu; Lu, Yi; Wu, Jia-Chuan; Bie, Like; Xia, Lu; Gong, Biao

    2016-02-01

    Accurately differentiating malignant diseases from benign ones in patients having bile duct obstruction is of significant importance and remains a major clinical problem. This study investigated the diagnostic yield of endoscopic retrograde cholangiography/intraductal ultrasound (ERC/IDUS) in distinguishing malignant from benign bile duct obstruction and assessed some image findings from ERC/IDUS which might be useful in differentiation. From January 2008 to January 2015, patients who underwent ERC/IDUS for bile duct obstruction were enrolled. Patient's ERC/IDUS diagnosis was compared with the final diagnosis determined by pathologic findings and/or clinical outcome of follow-up. One hundred and ninety-three patients with bile duct obstruction were included. IDUS correctly identified 94 of 97 malignant diseases and 76 of 96 benign diseases with sensitivity, specificity, and accuracy rate of 96.91, 79.17, and 88.08 %, respectively. Additionally, the accuracy rate of IDUS for diagnosis of proximal bile duct obstruction was higher than that of distal bile duct obstruction (98.08 vs. 82.73 %, p = 0.006). Besides, there was a significant difference in the length at the obstruction site between benign and malignant diseases (13.76 ± 7.37 vs. 19.97 ± 11.37 mm, p 7 mm without extrinsic compression had a positive predictive value (PPV) of 100 % for including malignancy, while length ≧20 mm demonstrated a PPV of 93.44 %. ERC/IDUS is effective in distinguishing malignant from benign bile duct obstruction, thus helping in further clinical management.

  17. Utility of dysphagia grade in predicting endoscopic ultrasound T-stage of non-metastatic esophageal cancer.

    Science.gov (United States)

    Fang, T C; Oh, Y S; Szabo, A; Khan, A; Dua, K S

    2016-08-01

    Patients with non-metastatic esophageal cancer routinely undergo endoscopic ultrasound (EUS) for loco-regional staging. Neoadjuvant therapy is recommended for ≥T3 tumors while upfront surgery can be considered for ≤T2 lesions. The aim of this study was to determine if the degree of dysphagia can predict the EUS T-stage of esophageal cancer. One hundred eleven consecutive patients with non-metastatic esophageal cancer were retrospectively reviewed from a database. Prior to EUS, patients' dysphagia grade was recorded. Correlation between dysphagia grade and EUS T-stage, especially in reference to predicting ≥T3 stage, was determined. The correlation of dysphagia grade with EUS T-stage (Kendall's tau coefficient) was 0.49 (P dysphagia grade ≥2 (can only swallow semi-solids/liquids) for T3 cancer were 56% (95% confidence interval [CI] 43-67%) and 93% (95% CI 79-98%), respectively. The sensitivity, specificity, and positive predictive value of dysphagia grade ≥3 (can only swallow liquids or total dysphagia) for T3 lesions were 36% (95% CI 25-48%), 100% (95% CI 89-100%), and 100% (95% CI 83-100%), respectively. Overall, there was a significant positive correlation between dysphagia grade and the EUS T-stage of esophageal cancer. All patients with dysphagia grade ≥3 had T3 lesions. This may have clinical implications for patients who can only swallow liquids or have complete dysphagia by allowing for prompt initiation of neoadjuvant therapy, especially in countries/centers where EUS service is difficult to access in a timely manner or not available. © 2015 International Society for Diseases of the Esophagus.

  18. Efficacy of an artificial neural network-based approach to endoscopic ultrasound elastography in diagnosis of focal pancreatic masses.

    Science.gov (United States)

    Săftoiu, Adrian; Vilmann, Peter; Gorunescu, Florin; Janssen, Jan; Hocke, Michael; Larsen, Michael; Iglesias-Garcia, Julio; Arcidiacono, Paolo; Will, Uwe; Giovannini, Marc; Dietrich, Cristoph F; Havre, Roald; Gheorghe, Cristian; McKay, Colin; Gheonea, Dan Ionuţ; Ciurea, Tudorel

    2012-01-01

    By using strain assessment, real-time endoscopic ultrasound (EUS) elastography provides additional information about a lesion's characteristics in the pancreas. We assessed the accuracy of real-time EUS elastography in focal pancreatic lesions using computer-aided diagnosis by artificial neural network analysis. We performed a prospective, blinded, multicentric study at of 258 patients (774 recordings from EUS elastography) who were diagnosed with chronic pancreatitis (n = 47) or pancreatic adenocarcinoma (n = 211) from 13 tertiary academic medical centers in Europe (the European EUS Elastography Multicentric Study Group). We used postprocessing software analysis to compute individual frames of elastography movies recorded by retrieving hue histogram data from a dynamic sequence of EUS elastography into a numeric matrix. The data then were analyzed in an extended neural network analysis, to automatically differentiate benign from malignant patterns. The neural computing approach had 91.14% training accuracy (95% confidence interval [CI], 89.87%-92.42%) and 84.27% testing accuracy (95% CI, 83.09%-85.44%). These results were obtained using the 10-fold cross-validation technique. The statistical analysis of the classification process showed a sensitivity of 87.59%, a specificity of 82.94%, a positive predictive value of 96.25%, and a negative predictive value of 57.22%. Moreover, the corresponding area under the receiver operating characteristic curve was 0.94 (95% CI, 0.91%-0.97%), which was significantly higher than the values obtained by simple mean hue histogram analysis, for which the area under the receiver operating characteristic was 0.85. Use of the artificial intelligence methodology via artificial neural networks supports the medical decision process, providing fast and accurate diagnoses. Copyright © 2012 AGA Institute. Published by Elsevier Inc. All rights reserved.

  19. Increased Incidence of Benign Pancreatic Pathology following Pancreaticoduodenectomy for Presumed Malignancy over 10 Years despite Increased Use of Endoscopic Ultrasound

    Directory of Open Access Journals (Sweden)

    Shadi S. Yarandi

    2014-01-01

    Full Text Available Despite using imaging studies, tissue sampling, and serologic tests about 5–10% of surgeries done for presumed pancreatic malignancies will have benign findings on final pathology. Endoscopic ultrasound (EUS is used with increasing frequency to study pancreatic masses. The aim of this study is to examine the effect of EUS on prevalence of benign diseases undergoing Whipple over the last decade. Patients who underwent Whipple procedure for presumed malignancy at Emory University Hospital from 1998 to 2011 were selected. Demographic data, history of smoking and drinking, history of diabetes and pancreatitis, imaging data, pathology reports, and tumor markers were extracted. 878 patients were found. 95 (10.82% patients had benign disease. Prevalence of benign finding had increased over the recent years despite using more EUS. Logistic regression models showed that abdominal pain (OR: 5.829, 95% CI 2.681–12.674, P ≤ 0.001 and alcohol abuse (OR: 3.221, CI 95%: 1.362–7.261, P: 0.002 were predictors of benign diseases. Jaundice (OR: 0.221, 95% CI: 0.084–0.58, P: 0.002, mass (OR: 0.145, 95% CI: 0.043–0.485, P: 0.008, and ductal dilation (OR: 0.297, 95% CI 0.134–0.657, P: 0.003 were associated with malignancy. Use of imaging studies, ERCP, and EUS has not decreased the percentage of benign findings after surgery for presumed pancreatic malignancy.

  20. Non-small-cell lung cancer: detection of mediastinal lymph node metastases by endoscopic ultrasound and CT

    International Nuclear Information System (INIS)

    Potepan, P.; Meroni, E.; Spagnoli, I.; Milella, M.; Danesini, G.M.; Laffranchi, A.; Civelli, E.; Alloisio, M.; Mariani, L.; Spinelli, P.; Guzzon, A.

    1996-01-01

    In this prospective study endoscopic ultrasound (EUS) and computed tomography (CT) were evaluated to compare diagnostic accuracy of the two methods. They were performed for nodal staging in selected patients admitted to our institution for non-small-cell lung cancer (NSCLC). From February 1992 to July 1993, 45 patients were recruited for the study when N3 and N2 nodal involvement were excluded on standard chest X-ray. All the patients completed EUS and CT exams for staging before treatment. The results of sensitivity, specificity and accuracy were obtained in 30 patients who underwent surgical treatment with macroscopically radical resection of T and N, which allowed a complete surgical and histological comparison of CT and EUS findings. On a per-patient basis CT results were: Sensitivity 63.6%, specificity 78.9% and accuracy of 73.3%; on a nodal station basis sensitivity, specificity and accuracy were 70.0%, 85,1% and 81.6%, respectively. The EUS evaluation showed, on a per-patient basis, values of sensitivity 45.5%, specificity 57.9% and overall diagnostic accuracy of 53.3%. On a nodal station basis the results were 50.0%, 86.6% and 78.2%, respectively. The results obtained in the 30 patients when both techniques were taken in association regarding senstivity (90.9%), specificity (73.7%) and accuracy (80.0%) on a per-patient basis suggest that the association of EUS and CT offers the best approach for preoperative staging of NSCLC. (orig.)

  1. Electrocautery vs non-electrocautery dilation catheters in endoscopic ultrasonography-guided pancreatic fluid collection drainage

    Science.gov (United States)

    Kitamura, Katsuya; Yamamiya, Akira; Ishii, Yu; Nomoto, Tomohiro; Honma, Tadashi; Yoshida, Hitoshi

    2016-01-01

    AIM: To investigate the safety and utility of an electrocautery dilation catheter for endoscopic ultrasonography (EUS)-guided pancreatic fluid collection drainage. METHODS: A single-center, exploratory, retrospective study was conducted between August 2010 and August 2014. This study was approved by the Medical Ethics Committee of our institution. Informed, written consent was obtained from each patient prior to the procedure. The subjects included 28 consecutive patients who underwent EUS-guided transmural drainage (EUS-TD) for symptomatic pancreatic and peripancreatic fluid collections (PFCs) by fine needle aspiration using a 19-gauge needle. These patients were retrospectively divided into two groups based on the use of an electrocautery dilation catheter as a fistula dilation device; 15 patients were treated with an electrocautery dilation catheter (electrocautery group), and 13 patients were treated with a non-electrocautery dilation catheter (non-electrocautery group). We evaluated the technical and clinical successes and the adverse events associated with EUS-TD for the treatment of PFCs between the two groups. RESULTS: There were no significant differences in age, sex, type, location and diameter of PFCs between the groups. Thirteen patients (87%) in the electrocautery group and 10 patients (77%) in the non-electrocautery group presented with infected PFCs. The technical success rates of EUS-TD for the treatment of PFCs were 100% (15/15) and 100% (13/13) for the electrocautery and the non-electrocautery groups, respectively. The clinical success rates of EUS-TD for the treatment of PFCs were 67% (10/15) and 69% (9/13) for the electrocautery and the non-electrocautery groups, respectively (P = 0.794). The procedure time of EUS-TD for the treatment of PFCs in the electrocautery group was significantly shorter than that of the non-electrocautery group (mean ± SD: 30 ± 12 min vs 52 ± 20 min, P electrocautery and the non-electrocautery groups, respectively (P

  2. Endobronchial ultrasound-guided biopsy performed under optimal conditions in patients with known or suspected lung cancer may render mediastinoscopy unnecessary

    DEFF Research Database (Denmark)

    Clementsen, Paul F; Skov, Birgit G; Vilmann, Peter

    2014-01-01

    BACKGROUND: Mediastinoscopy is the gold standard for preoperative mediastinal staging of patients with suspected or proven lung cancer. Since the development of endoscopic ultrasound-guided biopsy via the trachea (EBUS-TBNA), this status has been challenged. The purpose of the study was to examine...... that mediastinoscopy gives access to. METHODS: A total of 95 consecutive patients with known or suspected lung cancer were referred for staging by EBUS-TBNA, which was performed as described. RESULTS: Benign and malignant disease was found in the mediastinum of 6 and 13 patients, respectively. The remaining 76...... whether mediastinoscopy is necessary, when EBUS-TBNA is performed in a center with (1) a high level of expertise, (2) "bed side" microscopy by a pathologist, (3) general anesthesia, and (4) achievement of representative tissue from station 4R, 7 and 4L, that is, the same mediastinal stations...

  3. Ultrasound guided pleural biopsy in undiagnosed exudative pleural effusion patients

    OpenAIRE

    Adel S. Ahmed; Mostafa I. Ragab; Alaa eldin M. Elgazaar; Nagwan A. Ismail

    2016-01-01

    Introduction: Pleural biopsy for pathological confirmation is the standard diagnostic procedure for pleural diseases, transthoracic ultrasonography (TUS) has evolved as an important imaging tool for diagnosing pleural and pulmonary conditions. Aim of the study: To assess the diagnostic yield of TUS guided pleural biopsy versus both CT guided and thoracoscopic pleural biopsy in the diagnosis of undiagnosed exudative pleural effusion. Patients and methods: The study was conducted at chest...

  4. Endogenous Catalytic Generation of O2 Bubbles for In Situ Ultrasound-Guided High Intensity Focused Ultrasound Ablation.

    Science.gov (United States)

    Liu, Tianzhi; Zhang, Nan; Wang, Zhigang; Wu, Meiying; Chen, Yu; Ma, Ming; Chen, Hangrong; Shi, Jianlin

    2017-09-26

    High intensity focused ultrasound (HIFU) surgery generally suffers from poor precision and low efficiency in clinical application, especially for cancer therapy. Herein, a multiscale hybrid catalytic nanoreactor (catalase@MONs, abbreviated as C@M) has been developed as a tumor-sensitive contrast and synergistic agent (C&SA) for ultrasound-guided HIFU cancer surgery, by integrating dendritic-structured mesoporous organosilica nanoparticles (MONs) and catalase immobilized in the large open pore channels of MONs. Such a hybrid nanoreactor exhibited sensitive catalytic activity toward H 2 O 2 , facilitating the continuous O 2 gas generation in a relatively mild manner even if incubated with 10 μM H 2 O 2 , which finally led to enhanced ablation in the tissue-mimicking PAA gel model after HIFU exposure mainly resulting from intensified cavitation effect. The C@M nanoparticles could be accumulated within the H 2 O 2 -enriched tumor region through enhanced permeability and retention effect, enabling durable contrast enhancement of ultrasound imaging, and highly efficient tumor ablation under relatively low power of HIFU exposure in vivo. Very different from the traditional perfluorocarbon-based C&SA, such an on-demand catalytic nanoreactor could realize the accurate positioning of tumor without HIFU prestimulation and efficient HIFU ablation with a much safer power output, which is highly desired in clinical HIFU application.

  5. Ultrasound-guided approach for axillary brachial plexus, femoral nerve, and sciatic nerve blocks in dogs.

    Science.gov (United States)

    Campoy, Luis; Bezuidenhout, Abraham J; Gleed, Robin D; Martin-Flores, Manuel; Raw, Robert M; Santare, Carrie L; Jay, Ariane R; Wang, Annie L

    2010-03-01

    To describe an ultrasound-guided technique and the anatomical basis for three clinically useful nerve blocks in dogs. Prospective experimental trial. Four hound-cross dogs aged 2 +/- 0 years (mean +/- SD) weighing 30 +/- 5 kg and four Beagles aged 2 +/- 0 years and weighing 8.5 +/- 0.5 kg. Axillary brachial plexus, femoral, and sciatic combined ultrasound/electrolocation-guided nerve blocks were performed sequentially and bilaterally using a lidocaine solution mixed with methylene blue. Sciatic nerve blocks were not performed in the hounds. After the blocks, the dogs were euthanatized and each relevant site dissected. Axillary brachial plexus block Landmark blood vessels and the roots of the brachial plexus were identified by ultrasound in all eight dogs. Anatomical examination confirmed the relationship between the four ventral nerve roots (C6, C7, C8, and T1) and the axillary vessels. Three roots (C7, C8, and T1) were adequately stained bilaterally in all dogs. Femoral nerve block Landmark blood vessels (femoral artery and femoral vein), the femoral and saphenous nerves and the medial portion of the rectus femoris muscle were identified by ultrasound in all dogs. Anatomical examination confirmed the relationship between the femoral vessels, femoral nerve, and the rectus femoris muscle. The femoral nerves were adequately stained bilaterally in all dogs. Sciatic nerve block. Ultrasound landmarks (semimembranosus muscle, the fascia of the biceps femoris muscle and the sciatic nerve) could be identified in all of the dogs. In the four Beagles, anatomical examination confirmed the relationship between the biceps femoris muscle, the semimembranosus muscle, and the sciatic nerve. In the Beagles, all but one of the sciatic nerves were stained adequately. Ultrasound-guided needle insertion is an accurate method for depositing local anesthetic for axillary brachial plexus, femoral, and sciatic nerve blocks.

  6. Toward a real-time system for temporal enhanced ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Azizi, Shekoofeh; Van Woudenberg, Nathan; Sojoudi, Samira; Li, Ming; Xu, Sheng; Abu Anas, Emran M; Yan, Pingkun; Tahmasebi, Amir; Kwak, Jin Tae; Turkbey, Baris; Choyke, Peter; Pinto, Peter; Wood, Bradford; Mousavi, Parvin; Abolmaesumi, Purang

    2018-03-27

    We have previously proposed temporal enhanced ultrasound (TeUS) as a new paradigm for tissue characterization. TeUS is based on analyzing a sequence of ultrasound data with deep learning and has been demonstrated to be successful for detection of cancer in ultrasound-guided prostate biopsy. Our aim is to enable the dissemination of this technology to the community for large-scale clinical validation. In this paper, we present a unified software framework demonstrating near-real-time analysis of ultrasound data stream using a deep learning solution. The system integrates ultrasound imaging hardware, visualization and a deep learning back-end to build an accessible, flexible and robust platform. A client-server approach is used in order to run computationally expensive algorithms in parallel. We demonstrate the efficacy of the framework using two applications as case studies. First, we show that prostate cancer detection using near-real-time analysis of RF and B-mode TeUS data and deep learning is feasible. Second, we present real-time segmentation of ultrasound prostate data using an integrated deep learning solution. The system is evaluated for cancer detection accuracy on ultrasound data obtained from a large clinical study with 255 biopsy cores from 157 subjects. It is further assessed with an independent dataset with 21 biopsy targets from six subjects. In the first study, we achieve area under the curve, sensitivity, specificity and accuracy of 0.94, 0.77, 0.94 and 0.92, respectively, for the detection of prostate cancer. In the second study, we achieve an AUC of 0.85. Our results suggest that TeUS-guided biopsy can be potentially effective for the detection of prostate cancer.

  7. Ultrasound-guided core needle biopsy in diagnosis of abdominal and pelvic neoplasm in pediatric patients.

    Science.gov (United States)

    Wang, Hailing; Li, Fangxuan; Liu, Juntian; Zhang, Sheng

    2014-01-01

    Ultrasound-guided core needle biopsy of abdominal and pelvic masses in adults has gained tremendous popularity. However, the application of the same treatment in children is not as popular because of apprehensions regarding inadequate tissues for the biopsy and accidental puncture of vital organs. Data of the application of ultrasound-guided core needle biopsy in 105 pediatric patients with clinically or ultrasound-diagnosed abdominopelvic masses were reviewed. Diagnostic procedures were conducted in our institution from May 2011 to May 2013. The biopsies were conducted on 86 malignant lesions and 19 benign lesions. 86 malignant tumors comprised neuroblastomas (30 cases), hepatoblastomas (15 cases), nephroblastomas (11 cases), and primitive neuroectodermal tumors/malignant small round cells (6 cases). Among malignant tumor cases, only a pelvic primitive neuroectodermal tumor did not receive a pathological diagnosis. Therefore, the biopsy accuracy was 98.8 % in malignant tumor. However, the biopsies for one neuroblastomas and one malignant small round cell tumor were inadequate for cytogenetic analysis. Therefore, 96.5 % of the malignant tumor patients received complete diagnosis via biopsy. 19 benign tumors comprised mature teratoma (10 cases), hemangioendothelioma (3 cases), paraganglioma (2 cases), and infection (2 cases). The diagnostic accuracy for benign neoplasm was 100 %. Five patients experienced postoperative complications, including pain (2 patients), bleeding from the biopsy site (2 patients), and wound infection (1 patient). Ultrasound-guided core needle biopsy is an efficient, minimally invasive, accurate, and safe diagnostic method that can be applied in the management of abdominal or pelvic mass of pediatric patients.

  8. Treatment of Partial Rotator Cuff Tear with Ultrasound-guided Platelet-rich Plasma

    Directory of Open Access Journals (Sweden)

    Vetrivel Chezian Sengodan

    2017-01-01

    Full Text Available Background: The treatment of symptomatic partial rotator cuff tear has presented substantial challenge to orthopaedic surgeons as it can vary from conservative to surgical repair. Researches have established the influence of platelet rich plasma in healing damaged tissue. Currently very few data are available regarding the evidence of clinical and radiological outcome of partial rotator cuff tear treated with ultrasound guided platelet rich plasma injection in English literature. Materials and Methods: 20 patients with symptomatic partial rotator cuff tears were treated with ultrasound guided platelet rich plasma injection. Before and after the injection of platelet rich plasma scoring was done with visual analogue score, Constant shoulder score, and UCLA shoulder score at 8 weeks and third month. A review ultrasound was performed 8 weeks after platelet rich plasma injection to assess the rotator cuff status. Results: Our study showed statistically significant improvements in 17 patients in VAS pain score, constant shoulder score and UCLA shoulder score. No significant changes in ROM were noted when matched to the contra-lateral side (P < 0.001 at the 3 month follow-up. The study also showed good healing on radiological evaluation with ultrasonogram 8 weeks after platelet rich plasma injection. Conclusion: Ultrasound guided platelet rich plasma injection for partial rotator cuff tears is an effective procedure that leads to significant decrease in pain, improvement in shoulder functions, much cost-effective and less problematic compared to a surgical treatment.

  9. Ultrasound-guided truncal blocks: A new frontier in regional anaesthesia

    Directory of Open Access Journals (Sweden)

    Arunangshu Chakraborty

    2016-01-01

    Full Text Available The practice of regional anaesthesia is rapidly changing with the introduction of ultrasound into the working domain of the anaesthesiologist. New techniques are being pioneered. Among the recent techniques, notable are the truncal blocks, for example, the transversus abdominis plane block, rectus sheath block, hernia block and quadratus lumborum block in the abdomen and the pectoral nerves (Pecs block 1 and 2, serratus anterior plane block and intercostal nerve block. This narrative review covers the brief anatomical discourse along with technical description of the ultrasound-guided truncal blocks.

  10. The clinical value of trans-vaginal ultrasound-guided puncture in the treatment of pelvic abscess

    International Nuclear Information System (INIS)

    Wang Ping; Gong Wei

    2008-01-01

    Objective: To investigate the clinical value of trans-vaginal ultrasound-guided (TVS) puncture in the treatment of pelvic abscess. Methods 30 cases with pelvic abscess were treated by transvaginal ultrasound-guided puncture. The long-dated effects were followed-up. Results: 29 cases were cured by TVS puncture. Operation was performed in 1 patient because of invalid effect. The cure rate was 97%. Conclusion: Ultrasound-guided puncture is a safe and convenient method in the treatment of pelvic abscess. (authors)

  11. Ultrasound-Guided 50% Ethyl Alcohol Injection for Patients With Malleolar and Olecranon Bursitis: A Prospective Pilot Study

    Science.gov (United States)

    Hong, Ji Seong; Lee, Jin Hyung

    2016-01-01

    Objective To evaluate the feasibility and effect of ultrasound-guided ethyl alcohol injection on malleolar and olecranon synovial proliferative bursitis. Methods Twenty-four patients received ultrasound-guided 50% diluted ethyl alcohol injection at the site of synovial proliferative bursitis after aspiration of the free fluid. Results Swelling and symptoms significantly decreased in 13 of the 24 patients without any complications. Eleven patients had partial improvement in swelling and symptoms. Conclusion Ultrasound-guided alcohol injection could be an alternative therapeutic option before surgery in patients with chronic intractable malleolar and olecranon synovial proliferative bursitis. PMID:27152282

  12. Fluoroscopy- vs ultrasound-guided aspiration techniques in the management of periprosthetic joint infection: which is the best?

    Science.gov (United States)

    Randelli, Filippo; Brioschi, Marco; Randelli, Pietro; Ambrogi, Federico; Sdao, Silvana; Aliprandi, Alberto

    2018-01-01

    Fluid samples obtained from an affected joint still play a central role in the diagnosis of periprosthetic joint infection (PJI). It is the only preoperative test able to discover the causative microbiological agent. In the hip, fluid aspiration can be performed through fluoroscopy, ultrasound, or, less commonly, computed tomography. However, there is still a lack of consensus on which method is preferable in terms of efficacy and costbenefit. We, therefore, asked whether (1) the benefits in terms of sensitivity and specificity and (2) the costs were comparable between fluoroscopy- and ultrasound-guided joint aspirations in a suspicious of hip PJI. Between 2013 and 2016, 52 hip aspirations were performed on 49 patients with clinical, radiological, or serological suspicion of PJI, waiting for a revision surgery. The patients were divided in two groups: fluoroscopy- (n = 26) vs ultrasound-guided hip aspiration group (n = 26). These groups were also divided in control and infected patients. The criteria of MusculoSkeletal Infection Society (MSIS) were used, as gold standard, to define PJI. (1) Ultrasound-guided aspiration revealed valid sensitivity (89% vs 60%) and specificity (94% vs 81%) in comparison with fluoroscopic-guided aspiration. (2) The cost analysis was also in favor of ultrasound-guided aspiration (125.30€) than fluoroscopic-guided aspiration (343.58€). We concluded that ultrasound-guided hip aspiration could represent a valid, safe, and less expensive diagnostic alternative to fluoroscopic-guided aspiration in hip PJI.

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... inserted into a man's rectum to view the prostate. Transvaginal ultrasound. The transducer is inserted into a ... Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview Images related to General Ultrasound Videos ...

  14. Analysis of "dry" mesothelioma with ultrasound guided biopsies

    NARCIS (Netherlands)

    Stigt, Jos A.; Boers, James E.; Groen, Harry J. M.

    2012-01-01

    Background: Image-guided sampling of the thickened pleura is a sensitive approach in patients with malignant pleural mesothelioma with pleural effusion. Malignant pleural mesothelioma presenting without effusion however is more of a diagnostic challenge. In this study we report the diagnostic yield

  15. MR-guided focused ultrasound. Current and future applications

    International Nuclear Information System (INIS)

    Trumm, C.G.; Peller, M.; Clevert, D.A.; Stahl, R.; Reiser, M.; Napoli, A.; Matzko, M.

    2013-01-01

    High-intensity focused ultrasound (synonyms FUS and HIFU) under magnetic resonance imaging (MRI) guidance (synonyms MRgFUS and MR-HIFU) is a completely non-invasive technology for accurate thermal ablation of a target tissue while neighboring tissues and organs are preserved. The combination of FUS with MRI for planning, (near) real-time monitoring and outcome assessment of treatment markedly enhances the safety of the procedure. The MRgFUS procedure is clinically established in particular for the treatment of symptomatic uterine fibroids, followed by palliative ablation of painful bone metastases. Furthermore, promising results have been shown for the treatment of adenomyosis, malignant tumors of the prostate, breast and liver and for various intracranial applications, such as thermal ablation of brain tumors, functional neurosurgery and transient disruption of the blood-brain barrier. (orig.) [de

  16. [MR-guided focused ultrasound. Current and future applications].

    Science.gov (United States)

    Trumm, C G; Napoli, A; Peller, M; Clevert, D-A; Stahl, R; Reiser, M; Matzko, M

    2013-03-01

    High-intensity focused ultrasound (synonyms FUS and HIFU) under magnetic resonance imaging (MRI) guidance (synonyms MRgFUS and MR-HIFU) is a completely non-invasive technology for accurate thermal ablation of a target tissue while neighboring tissues and organs are preserved. The combination of FUS with MRI for planning, (near) real-time monitoring and outcome assessment of treatment markedly enhances the safety of the procedure. The MRgFUS procedure is clinically established in particular for the treatment of symptomatic uterine fibroids, followed by palliative ablation of painful bone metastases. Furthermore, promising results have been shown for the treatment of adenomyosis, malignant tumors of the prostate, breast and liver and for various intracranial applications, such as thermal ablation of brain tumors, functional neurosurgery and transient disruption of the blood-brain barrier.

  17. A comparison of complications between ultrasound-guided prostate brachytherapy and open prostate brachytherapy

    International Nuclear Information System (INIS)

    Benoit, Ronald M.; Naslund, Michael J.; Cohen, Jeffrey K.

    2000-01-01

    Purpose: Prostate brachytherapy has reemerged during the 1990s as a treatment for clinically localized prostate cancer. The renewed popularity of prostate brachytherapy is largely due to the use of transrectal ultrasound of the prostate, which allows for more accurate isotope placement within the prostate when compared to the open approach. The present study investigates whether this improved cancer control is at the expense of increased morbidity by comparing the morbidity after transrectal ultrasound-guided prostate brachytherapy to the morbidity after prostate brachytherapy performed via an open approach. Methods and Materials: All men in the Medicare population who underwent prostate brachytherapy in the year 1991 were identified. These men were further stratified into those men who underwent prostate brachytherapy via an open approach and the men who underwent prostate brachytherapy with ultrasound guidance. All subsequent inpatient, outpatient, and physician (Part B) Medicare claims for these men from the years 1991-1993 were then analyzed to determine outcomes. Results: In the year 1991, 2124 men in the Medicare population underwent prostate brachytherapy. An open approach was used in 715 men (33.7%), and ultrasound guidance was used in 1409 men (66.3%). Mean age for both cohorts was 73.7 years with a range of 50.7-92.8 years for the ultrasound group and 60.6-92.1 years for the open group. A surgical procedure for the relief of bladder outlet obstruction was performed in 122 men (8.6%) in the ultrasound group and in 54 men (7.6%) in the open group. An artificial urinary sphincter was placed in 2 men (0.14%) in the ultrasound group and in 2 men (0.28%) in the open group. A penile prosthesis was implanted in 10 men (0.71%) in the ultrasound group and in 4 men (0.56%) in the open group. A diagnosis code for urinary incontinence was carried by 95 men (6.7%) in the ultrasound group and by 45 men (6.3%) in the open group. A diagnosis code for erectile dysfunction

  18. Ultrasound

    Science.gov (United States)

    Ultrasound is a useful procedure for monitoring the baby's development in the uterus. Ultrasound uses inaudible sound waves to produce a two-dimensional image of the baby while inside the mother's ...

  19. Ultrasound-Guided Angioplasty of Dysfunctional Vascular Access for Haemodialysis. The Pros and Cons

    Energy Technology Data Exchange (ETDEWEB)

    García-Medina, J., E-mail: josegmedina57@gmail.com [“Reina Sofia” University Hospital, Vascular and Interventional Radiology Unit, Department of Radiology (Spain); García-Alfonso, J. J., E-mail: juanjozarandieta@gmail.com [University of Murcia, Faculty of Medicine (Spain)

    2017-05-15

    PurposeTo describe the benefits and the disadvantages of angioplasty in dialysis fistulas using only ultrasound guidance.Materials and MethodsThis is a prospective study in 132 failing or non-maturing arteriovenous accesses that underwent 189 ultrasound-guided balloon angioplasties. The technical success was defined as non-use of X-ray fluoroscopy during the procedure.Results127 procedures (67%) were successfully completed without fluoroscopy. Most failures were due to difficulty to traverse aneurismal segments, as well as anastomotic stenoses. Including initial failures, the primary patency rates at 6, 12 months and 2 years were 75 ± 3, 41 ± 3 and 14 ± 2%, respectively.ConclusionEndovascular repair of the dysfunctional vascular access for haemodialysis under ultrasound guidance is feasible and safe in roughly two-thirds of cases.

  20. Technical guide to evaluate upper limb joints (shoulder, elbow and wrist) by ultrasound

    International Nuclear Information System (INIS)

    Obregon Baez, Luis Rafael

    2014-01-01

    A guideline to follow is offered to radiologists and residents of radiology service of medical imaging, when evaluating by ultrasound the shoulder joints, elbow, wrist. The importance to performing of musculoskeletal ultrasound by its pathology variable is established. The use of appropriate equipment and effective application of the techniques exposed of echography exploration have made enable the valuation of many pathologies with high sensitivity and specificity. The echography has been the musculoskeletal imaging technique that more rapidly has evolved. Currently, this technique has been replaced by magnetic resonance imaging in various clinical fields and also serves as a complement to other techniques. Exposed techniques have been of great benefit for radiologists medical and residents, obtaining with its use a quick guide for the realization of upper limb musculoskeletal ultrasounds. The appropriate and easy techniques are better known for the evaluation of these structures, and so document both sports injuries, as joint and rheumatic diseases [es

  1. Derivation of a Performance Checklist for Ultrasound-Guided Arthrocentesis Using the Modified Delphi Method.

    Science.gov (United States)

    Kunz, Derek; Pariyadath, Manoj; Wittler, Mary; Askew, Kim; Manthey, David; Hartman, Nicholas

    2017-06-01

    Arthrocentesis is an important skill for physicians in multiple specialties. Recent studies indicate a superior safety and performance profile for this procedure using ultrasound guidance for needle placement, and improving quality of care requires a valid measurement of competency using this modality. We endeavored to create a validated tool to assess the performance of this procedure using the modified Delphi technique and experts in multiple disciplines across the United States. We derived a 22-item checklist designed to assess competency for the completion of ultrasound-guided arthrocentesis, which demonstrated a Cronbach's alpha of 0.89, indicating an excellent degree of internal consistency. Although we were able to demonstrate content validity for this tool, further validity evidence should be acquired after the tool is used and studied in clinical and simulated contexts. © 2017 by the American Institute of Ultrasound in Medicine.

  2. How to achieve ultrasound-guided femoral venous access: the new standard of care in the electrophysiology laboratory.

    Science.gov (United States)

    Wiles, Benedict M; Child, Nicholas; Roberts, Paul R

    2017-06-01

    Bedside vascular ultrasound machines are increasingly available. They are used to facilitate safer vascular access across a number of different specialties. In the electrophysiology laboratory however, where patients are frequently anticoagulated and require the insertion of multiple venous sheaths, anatomical landmark techniques predominate. Despite the high number of vascular complications associated with electrophysiological procedures and the increasing evidence to support its use in electrophysiology, ultrasound remains underutilised. A new standard of care is required. A comprehensive technical report, providing a detailed explanation of this important technique, will provide other electrophysiology centres with the knowledge and justification for adopting ultrasound guidance as their standard practice. We review the increasing body of evidence which demonstrates that routine ultrasound usage can substantially improve the safety of femoral venous access in the electrophysiology laboratory. We offer a comprehensive technical report to guide operators through the process of ultrasound-guided venous access, with a specific focus on the electrophysiology laboratory. Additionally, we detail a novel technique which utilises real-time colour Doppler ultrasound to accurately identify needle tip location during venous puncture. The use of vascular ultrasound to guide femoral venous cannulation is rapid, inexpensive and easily learnt. Ultrasound is readily available and offers the potential to significantly reduce vascular complications in the unique setting of the electrophysiology laboratory. Ultrasound guidance to achieve femoral venous access should be the new standard of care in electrophysiology.

  3. Evaluation of a Standardized Program for Training Practicing Anesthesiologists in Ultrasound-Guided Regional Anesthesia Skills.

    Science.gov (United States)

    Mariano, Edward R; Harrison, T Kyle; Kim, T Edward; Kan, Jack; Shum, Cynthia; Gaba, David M; Ganaway, Toni; Kou, Alex; Udani, Ankeet D; Howard, Steven K

    2015-10-01

    Practicing anesthesiologists have generally not received formal training in ultrasound-guided perineural catheter insertion. We designed this study to determine the efficacy of a standardized teaching program in this population. Anesthesiologists in practice for 10 years or more were recruited and enrolled to participate in a 1-day program: lectures and live-model ultrasound scanning (morning) and faculty-led iterative practice and mannequin-based simulation (afternoon). Participants were assessed and recorded while performing ultrasound-guided perineural catheter insertion at baseline, at midday (interval), and after the program (final). Videos were scored by 2 blinded reviewers using a composite tool and global rating scale. Participants were surveyed every 3 months for 1 year to report the number of procedures, efficacy of teaching methods, and implementation obstacles. Thirty-two participants were enrolled and completed the program; 31 of 32 (97%) completed the 1-year follow-up. Final scores [median (10th-90th percentiles)] were 21.5 (14.5-28.0) of 30 points compared to 14.0 (9.0-20.0) at interval (P < .001 versus final) and 12.0 (8.5-17.5) at baseline (P < .001 versus final), with no difference between interval and baseline. The global rating scale showed an identical pattern. Twelve of 26 participants without previous experience performed at least 1 perineural catheter insertion after training (P < .001). However, there were no differences in the monthly average number of procedures or complications after the course when compared to baseline. Practicing anesthesiologists without previous training in ultrasound-guided regional anesthesia can acquire perineural catheter insertion skills after a 1-day standardized course, but changing clinical practice remains a challenge. © 2015 by the American Institute of Ultrasound in Medicine.

  4. How good is endoscopic ultrasound for TNM staging of gastric cancers? A meta-analysis and systematic review

    Institute of Scientific and Technical Information of China (English)

    Srinivas Reddy Puli; Jyotsna Batapati Krishna Reddy; Matthew L Bechtold; Mainor R Antillon; Jamal A Ibdah

    2008-01-01

    AIM: To evaluate the accuracy of endoscopic ultrasound (EUS) for staging of gastric cancers.METHODS: Only EUS studies confirmed by surgery were selected. Only studies from which a 2×2 table could be constructed for true positive, false negative, false positive and true negative values were included. Articles were searched in Medline, Pubmed, Ovid journals, Cumulative index for nursing & allied health literature, International pharmaceutical abstracts, old Medline, Medline nonindexed citations, and Cochrane control trial registry. Two reviewers independently searched and extracted data. The differences were resolved by mutual agreement.2×2 tables were constructed with the data extracted from each study. Meta-analysis for the accuracy of EUS was analyzed by calculating pooled estimates of sensitivity, specificity, likelihood ratios, and diagnostic odds ratio. Pooling was conducted by both the Mantel-Haenszel method (fixed effects model) and DerSimonian Laird method (random effects model). The heterogeneity of studies was tested using Cochran's Q test based upon inverse variance weights.RESULTS: Initial search identified 1620 reference articles and of these, 376 relevant articles were selected and reviewed. Twenty-two studies (n=1896) which met the inclusion criteria were included in this analysis. Pooled sensitivity of T1 was 88.1% (95% CI:84.5-91.1) and T2 was 82.3% (95% CI: 78.2-86.0). For T3, pooled sensitivity was 89.7% (95% CI:87.1-92.0). T4 had a pooled sensitivity of 99.2% (95% CI: 97.1-99.9). For nodal staging, the pooled sensitivity for N1 was 58.2% (95% CI: 53.5-62.8) and N2 was 64.9% (95% CI: 60.8-68.8). Pooled sensitivity to diagnose distant metastasis was 73.2% (95% CI: 63.2-81.7). The P for chi-squared heterogeneity for all the pooled accuracy estimates was>0.10.CONCLUSION: EUS results are more accurate with advanced disease than early disease. If EUS diagnoses advanced disease, such as T4 disease, the patient is 500 times more likely to have true

  5. The role of ultrasound guided percutaneous needle aspiration and lavage (barbotage in the treatment of calcific tendinitis

    Directory of Open Access Journals (Sweden)

    Gamal Niazi

    2015-03-01

    Conclusion: Ultrasound guided aspiration and lavage (barbotage is a highly effective, less aggressive method of treatment in cases of calcific tendinosis, especially for cases with severe pain that does not respond to other conservative methods.

  6. Comparative study between ultrasound guided tap block and paravertebral block in upper abdominal surgeries. Randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Ruqaya M. Elsayed

    2017-01-01

    Conclusion: We concluded that ultrasound guided transversus abdominis plane block and thoracic paravertebral block were safe and effective anesthetic technique for upper abdominal surgery with longer and potent postoperative analgesia in thoracic paravertebral block than transversus abdominis block.

  7. Ultrasound-guided supra-acetabular pin placement in pelvic external fixation: description of a surgical technique and results.

    Science.gov (United States)

    Chana-Rodríguez, Francisco; Cuervas-Mons, Manuel; Rojo-Manaute, José; Mora, Félix; Arnal, Juan; Vaquero-Martín, Javier

    2017-11-01

    Pelvic fracture in trauma patients can lead to hemodynamic instability. External fixation is a treatment capable of stabilizing these injuries in the context of damage control surgery. Supra-acetabular pin offers the greater biomechanical stability but requires the use of intraoperative fluoroscopy. The aim of this study was to analyze our results for an ultrasound-guided supra-acetabular pinning. Cross-sectional study with cadaveric specimens. Ultrasound-guided pin placement assessed by fluoroscopy and dissection. Fourteen ultrasound-guided supra-acetabular pins were placed in seven cadaveric specimens. Excellent placement in all cases, evaluated with radiological control. Good qualitative bone fixation after dissection. One femoral cutaneous nerve was not found during anatomic dissection and was assumed injured. Ultrasound-guided supra-acetabular pin placement is a feasible and effective technique. Our study indicates that pin placement without intraoperative fluoroscopy is feasible without compromising the reliability of its placement. © 2017 Elsevier Ltd. All rights reserved.

  8. The Usefulness of Intensivist-Performed Bedside Drainage of Pleural Effusion via Ultrasound-Guided Pigtail Catheter

    Directory of Open Access Journals (Sweden)

    Joo Won Min

    2014-08-01

    CONCLUSIONS: Intensivist-performed bedside drainage of pleural effusion via ultrasound (US-guided pigtail catheter is useful and safe and may be recommended in some patients in an intensive care unit.

  9. Compensated Row-Column Ultrasound Imaging System Using Multilayered Edge Guided Stochastically Fully Connected Random Fields.

    Science.gov (United States)

    Ben Daya, Ibrahim; Chen, Albert I H; Shafiee, Mohammad Javad; Wong, Alexander; Yeow, John T W

    2017-09-06

    The row-column method received a lot of attention for 3-D ultrasound imaging. By reducing the number of connections required to address the 2-D array and therefore reducing the amount of data to handle, this addressing method allows for real time 3-D imaging. Row-column still has its limitations: the issues of sparsity, speckle noise inherent to ultrasound, the spatially varying point spread function, and the ghosting artifacts inherent to the row-column method must all be taken into account when building a reconstruction framework. In this research, we build on a previously published system and propose an edge-guided, compensated row-column ultrasound imaging system that incorporates multilayered edge-guided stochastically fully connected conditional random fields to address the limitations of the row-column method. Tests carried out on simulated and real row-column ultrasound images show the effectiveness of our proposed system over other published systems. Visual assessment show our proposed system's potential at preserving edges and reducing speckle. Quantitative analysis shows that our proposed system outperforms previously published systems when evaluated with metrics such as Peak Signal-to-Noise Ratio, Coefficient of Correlation, and Effective Number of Looks. These results show the potential of our proposed system as an effective tool for enhancing 3-D row-column imaging.

  10. Point-of-Care Ultrasound-Guided Percutaneous Cannulation of Extracorporeal Membrane Oxygenation: Make it Simple.

    Science.gov (United States)

    Ahn, Hong Joon; Lee, Jun Wan; Joo, Ki Hyuk; You, Yeon Ho; Ryu, Seung; Lee, Jin Woong; Kim, Seung Whan

    2017-12-30

    Cannulation of the great vessels is required for extracorporeal membrane oxygenation (ECMO). Currently, there is no guideline for optimal imaging modalities during percutaneous cannulation of ECMO. The purpose of this study was to describe percutaneous cannulation guided by point-of-care ultrasound (POCUS) for ECMO and compare it with fluoroscopy and landmark guidance. Three groups (POCUS-, fluoroscopy-, and landmark-guided) of percutaneous cannulation for ECMO were analyzed retrospectively in a tertiary academic hospital. In the POCUS-guided group, visual confirmation of guidewire and cannula by ultrasound in both the access and return cannula were essential for successful cannulation. Fluoroscopy- and landmark-guided groups were cannulated with the conventional technique. A total of 128 patients were treated by ECMO during the study period, of which 94 (73.4%) cases were venoarterial ECMO. This included 56 cases of extracorporeal cardiopulmonary resuscitation. Also, there were 30 (23.4%) cases of venovenous ECMO and 4 (3.1%) cases of venoarteriovenous ECMO. A total of 71 (55.5%) patients were cannulated under POCUS guidance, and 43 (33.6%) patients were cannulated under fluoroscopy guidance and 14 (10.9%) patients were cannulated by landmark guidance. No surgical cut downs were required. Misplacement of cannula occurred in 3 (2.3%) cases. All three occurred in the landmark-guided group. POCUS-guided cannulation is comparable to fluoroscopy-guided cannulation in terms of avoiding cannula misplacement. In our experience, POCUS-guided cannulation is a useful strategy over fluoroscopy- and landmark-guided cannulation during peripheral ECMO. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Optimizing MR imaging-guided navigation for focused ultrasound interventions in the brain

    Science.gov (United States)

    Werner, B.; Martin, E.; Bauer, R.; O'Gorman, R.

    2017-03-01

    MR imaging during transcranial MR imaging-guided Focused Ultrasound surgery (tcMRIgFUS) is challenging due to the complex ultrasound transducer setup and the water bolus used for acoustic coupling. Achievable image quality in the tcMRIgFUS setup using the standard body coil is significantly inferior to current neuroradiologic standards. As a consequence, MR image guidance for precise navigation in functional neurosurgical interventions using tcMRIgFUS is basically limited to the acquisition of MR coordinates of salient landmarks such as the anterior and posterior commissure for aligning a stereotactic atlas. Here, we show how improved MR image quality provided by a custom built MR coil and optimized MR imaging sequences can support imaging-guided navigation for functional tcMRIgFUS neurosurgery by visualizing anatomical landmarks that can be integrated into the navigation process to accommodate for patient specific anatomy.

  12. MR-Guided Focused Ultrasound for the Treatment of Uterine Fibroids

    International Nuclear Information System (INIS)

    Hesley, Gina K.; Gorny, Krzysztof R.; Woodrum, David A.

    2013-01-01

    Magnetic resonance imaging–guided focused ultrasound (MRgFUS) ablation of uterine fibroids provides a minimally invasive outpatient technique for targeting and treating symptomatic uterine fibroids. Magnetic resonance imaging provides a guidance platform that has high temporal and spatial resolution for guiding, as well as thermal monitoring of the procedure. The high-intensity focused ultrasound provides a mechanism for delivering large amounts of energy directly into the fibroid without causing detrimental effects to the nontarget tissues. Early and intermediate follow-up of patients treated with MRgFUS provided promising results on the efficacy of the technique for providing symptom relief to patients. As more long-term follow-up data are published, the efficacy of this technique can be compared to more invasive surgical and minimally invasive catheter treatments.

  13. Ultrasound-Guided Percutaneous Drainage of Neonatal Pyometrocolpos Under Local Anesthesia

    International Nuclear Information System (INIS)

    Algin, Oktay; Erdogan, Cuneyt; Kilic, Nizamettin

    2011-01-01

    Hydrometrocolpos is an uncommon congenital disorder with cystic dilatation of the vagina and uterus that occurs as a result of accumulated secretions from the reproductive tract due to distal genital tract obstruction. Secondary infection may also occur, resulting in pyometrocolpos, a potentially lethal disease. Immediate drainage of the cystic mass in patients determined to have pyometrocolpos is required to prevent or treat uropathy and septicemia until definitive corrective surgery can be performed. We report an unusual cause of obstructive uropathy in three infants: pyometrocolpos due to lower genital tract atresia. Ultrasound-guided percutaneous drainage of the pyometrocolpos resulted in dramatically improved clinical and laboratory findings in these patients. Ultrasound-guided percutaneous drainage under local anesthesia is a simple, minimally invasive, safe, and effective procedure that facilitates later successful corrective surgery and avoids the need for more complex drainage procedures.

  14. Ultrasound-Guided Drainage of Supralevator Hematoma in a Hemodynamically Stable Patient.

    Science.gov (United States)

    Mukhopadhyay, Debjani; Jennings, Paul E; Banerjee, Mamta; Gada, Ruta

    2015-12-01

    Paravaginal hematomas can be life-threatening. In patients with intact vaginal walls and perineum, they may pose a diagnostic and therapeutic challenge. Supralevator hematomas are much less common than infralevator hematomas. We present a case of puerperal hemorrhagic shock after a normal vaginal delivery in a low-risk parous woman resulting from an occult supralevator hematoma. Because the woman was hemodynamically unstable initially, she underwent a vaginal surgical drainage. A week later, the supravaginal hematoma reformed. At this time the patient was hemodynamically stable, and ultrasound-guided drainage was performed, which resulted in complete resolution of the hematoma within 10 days. In a clinically stable puerperal patient, ultrasound-guided drainage of a supralevator hematoma resulted in rapid and complete resolution of symptoms.

  15. Efficacy of ultrasound-guided thoracentesis catheter drainage for pleural effusion

    Science.gov (United States)

    Cao, Weitian; Wang, Yi; Zhou, Ningming; Xu, Bing

    2016-01-01

    The factors influencing the efficacy of ultrasound-guided thoracentesis catheter drainage were investigated in the present study. A retrospective analysis of clinical data from 435 patients who presented with a pleural effusion was performed. Patients were divided into a control group and an intervention group. Thirty-seven patients in the control group were given standard care using pleural puncture to draw the excess fluid. The 398 patients in the intervention group were treated using ultrasound-guided thoracentesis catheter drainage. The rate of successful drainage of a pleural effusion was significantly higher (Ppleural effusion. The efficacy of the procedure is related to the separation of pleural effusion, drainage tube type and tube diameter. PMID:28105155

  16. Ultrasound guided electrochemotherapy for the treatment of a clear cell thymoma in a cat

    Directory of Open Access Journals (Sweden)

    Enrico Pierluigi Spugnini

    2017-03-01

    Full Text Available A twelve-year-old male castrated domestic shorthair cat was presented for rapidly progressing respiratory distress. The cat was depressed, tachypneic and moderately responsive. Ultrasonography showed a mediastinal mass associated with a significant pleural effusion that needed tapping every five to seven days. Ultrasound guided biopsy yielded a diagnosis of clear cell thymoma upon histopathology. After complete staging procedures, the owner elected to treat the cat with electrochemotherapy (ECT using systemic bleomycin. Two sessions of ultrasound guided ECT were performed at two week intervals with trains of biphasic electric pulses applied using needle electrodes until complete coverage of the area was achieved. The treatment was well tolerated and resulted in partial remission (PR. Additional sessions were performed on a monthly basis. The cat is still in PR after fourteen months. ECT resulted in improved local control and should be considered among the available adjuvant treatments in pets carrying visceral tumors.

  17. Novel ultrasound-responsive chitosan/perfluorohexane nanodroplets for image-guided smart delivery of an anticancer agent: Curcumin.

    Science.gov (United States)

    Baghbani, Fatemeh; Chegeni, Mahdieh; Moztarzadeh, Fathollah; Hadian-Ghazvini, Samaneh; Raz, Majid

    2017-05-01

    Ultrasound-responsive nanodroplets are a class of new emerging smart drug delivery systems which provide image-guided nano-therapy of various diseases, especially cancers. Here, we developed multifunctional smart curcumin-loaded chitosan/perfluorohexane nanodroplets for contrast-ultrasound imaging and on-demand drug delivery. The nanodroplets were synthesized via nanoemulsion process. The optimal formulation with the size of 101.2nm and 77.8% curcumin entrapment was chosen for release study and cytotoxicity evaluation. Sonication at the frequency of 1MHz, 2W/cm 2 for 4min triggered the release of 63.5% of curcumin from optimal formulation (Cur-NDs-2). Ultrasound aided release study indicated that the concentration of perfluorohexane and the degree of acoustic droplet vaporization play important role in ultrasound-active drug release. B-mode ultrasound imaging confirmed strong ultrasound contrast of chitosan nanodroplets even at low concentrations via droplet to bubble transition. Finally, cytotoxicity of the ultrasound-responsive nanodroplets in the presence of ultrasound was evaluated in-vitro on 4T1 human breast cancer cells. Cell growth inhibitory effects of curcumin-loaded nanodroplets significantly increased by ultrasound exposure. According to the obtained results, these ultrasound responsive curcumin-loaded chitosan/perfluorohexane nanodroplets have a great potential for imaged-guided cancer therapy. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Endoscopic trans-nasal approach for biopsy of orbital tumors using image-guided neuro-navigation system

    International Nuclear Information System (INIS)

    Sieskiewicz, A.; Mariak, Z.; Rogowski, M.; Lyson, T.

    2008-01-01

    Histopathological diagnosis of intraorbital tumors is of crucial value for planning further therapy. The aim of the study was to explore clinical utility of image-guided endoscopy for biopsy of orbital tumors. Trans-nasal endoscopic biopsy of intraorbital mass lesions was performed in 6 patients using a neuro-navigation system (Medtronic Stealth Station Treon plus). The CT and MRI 1 mm slice images were fused by the system in order to visualise both bony and soft tissue structures. The anatomic fiducial registration protocol was used during the procedure. All lesions were precisely localised and the biopsies could be taken from the representative part of the pathological mass. None of the patients developed aggravation of ocular symptoms after the procedure. The operative corridor as well as the size of orbital wall fenestration could be limited to a minimum. The accuracy of neuro-navigation remained high and stable during the entire procedure. The image-guided neuro-navigation system facilitated endoscopic localisation and biopsy of intraorbital tumors and contributed to the reduction of surgical trauma during the procedure. The technique was particularly useful in small, medially located, retrobulbar tumors and in unclear situations when the structure of the lesion resembled surrounding intraorbital tissue. (author)

  19. Real-time ultrasound-guided spinal anaesthesia: a prospective observational study of a new approach.

    LENUS (Irish Health Repository)

    Conroy, P H

    2013-01-01

    Identification of the subarachnoid space has traditionally been achieved by either a blind landmark-guided approach or using prepuncture ultrasound assistance. To assess the feasibility of performing spinal anaesthesia under real-time ultrasound guidance in routine clinical practice we conducted a single center prospective observational study among patients undergoing lower limb orthopaedic surgery. A spinal needle was inserted unassisted within the ultrasound transducer imaging plane using a paramedian approach (i.e., the operator held the transducer in one hand and the spinal needle in the other). The primary outcome measure was the success rate of CSF acquisition under real-time ultrasound guidance with CSF being located in 97 out of 100 consecutive patients within median three needle passes (IQR 1-6). CSF was not acquired in three patients. Subsequent attempts combining landmark palpation and pre-puncture ultrasound scanning resulted in successful spinal anaesthesia in two of these patients with the third patient requiring general anaesthesia. Median time from spinal needle insertion until intrathecal injection completion was 1.2 minutes (IQR 0.83-4.1) demonstrating the feasibility of this technique in routine clinical practice.

  20. Novel needle guide reduces time to perform ultrasound-guided femoral nerve catheter placement: A randomised controlled trial.

    Science.gov (United States)

    Turan, Alparslan; Babazade, Rovnat; Elsharkawy, Hesham; Esa, Wael Ali Sakr; Maheshwari, Kamal; Farag, Ehab; Zimmerman, Nicole M; Soliman, Loran Mounir; Sessler, Daniel I

    2017-03-01

    Ultrasound-guided nerve blocks have become the standard when performing regional nerve blocks in anaesthesia. Infiniti Plus (CIVCO Medical Solutions, Kalona, Iowa, USA) is a needle guide that has been recently developed to help clinicians in performing ultrasound-guided nerve blocks. We tested the hypothesis that femoral nerve catheter placement carried out with the Infiniti Plus needle guide will be quicker to perform than without the Infiniti Plus. Secondary aims were to assess whether the Infiniti Plus needle guide decreased the number of block attempts and also whether it improved needle visibility. A randomised, controlled trial. Cleveland Clinic, Cleveland, Ohio, USA. We enrolled adult patients having elective total knee arthroplasty with a femoral nerve block and femoral nerve catheter. Patients, who were pregnant or those who had preexisting neuropathy involving the surgical limb, coagulopathy, infection at the block site or allergy to local anaesthetics were excluded. Patients were randomised into two groups to receive the ultrasound-guided femoral nerve catheter placement with or without the Infiniti Plus needle guide. The time taken to place the femoral nerve catheter, the number of attempts, the success rate and needle visibility were recorded. We used an overall α of 0.05 for both the primary and secondary analyses; the secondary analyses were Bonferroni corrected to control for multiple comparisons. The median (interquartile range Q1 to Q3) time to perform the femoral nerve catheter placement was 118 (100 to 150) s with Infiniti Plus and 177 (130 to 236) s without Infiniti Plus. Infiniti Plus significantly reduced the time spent performing femoral nerve catheterisation, with estimated ratio of means [(95% confidence interval), P value] of 0.67 [(0.60 to 0.75), P Infiniti Plus compared with no Infiniti Plus. However, Infiniti Plus had no effect on the odds of a successful femoral nerve catheter placement, number of attempts or percentage of perfect

  1. TU-B-210-00: MR-Guided Focused Ultrasound Therapy in Oncology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    MR guided focused ultrasound (MRgFUS), or alternatively high-intensity focused ultrasound (MRgHIFU), is approved for thermal ablative treatment of uterine fibroids and pain palliation in bone metastases. Ablation of malignant tumors is under active investigation in sites such as breast, prostate, brain, liver, kidney, pancreas, and soft tissue. Hyperthermia therapy with MRgFUS is also feasible, and may be used in conjunction with radiotherapy and for local targeted drug delivery. MRI allows in situ target definition and provides continuous temperature monitoring and subsequent thermal dose mapping during HIFU. Although MRgHIFU can be very precise, treatment of mobile organs is challenging and advanced techniques are required because of artifacts in MR temperature mapping, the need for intercostal firing, and need for gated HIFU or tracking of the lesion in real time. The first invited talk, “MR guided Focused Ultrasound Treatment of Tumors in Bone and Soft Tissue”, will summarize the treatment protocol and review results from treatment of bone tumors. In addition, efforts to extend this technology to treat both benign and malignant soft tissue tumors of the extremities will be presented. The second invited talk, “MRI guided High Intensity Focused Ultrasound – Advanced Approaches for Ablation and Hyperthermia”, will provide an overview of techniques that are in or near clinical trials for thermal ablation and hyperthermia, with an emphasis of applications in abdominal organs and breast, including methods for MRTI and tracking targets in moving organs. Learning Objectives: Learn background on devices and techniques for MR guided HIFU for cancer therapy Understand issues and current status of clinical MRg HIFU Understand strategies for compensating for organ movement during MRgHIFU Understand strategies for strategies for delivering hyperthermia with MRgHIFU CM - research collaboration with Philips.

  2. Design and application of model for training ultrasound-guided vascular cannulation in pediatric patients.

    Science.gov (United States)

    Pérez-Quevedo, O; López-Álvarez, J M; Limiñana-Cañal, J M; Loro-Ferrer, J F

    2016-01-01

    Central vascular cannulation is not a risk-free procedure, especially in pediatric patients. Newborn and infants are small and low-weighted, their vascular structures have high mobility because of tissue laxity and their vessels are superficial and with small diameter. These characteristics, together with the natural anatomical variability and poor collaboration of small children, make this technique more difficult to apply. Therefore, ultrasound imaging is increasingly being used to locate vessels and guide vascular access in this population. (a) To present a model that simulates the vascular system for training ultrasound-guided vascular access in pediatrics patients; (b) to ultrasound-guided vascular cannulation in the model. The model consisted of two components: (a) muscular component: avian muscle, (b) vascular component: elastic tube-like structure filled with fluid. 864 ecoguided punctures was realized in the model at different vessel depth and gauge measures were simulated, for two medical operators with different degree of experience. The average depth and diameter of vessel cannulated were 1.16 (0.42)cm and 0.43 (0.1)cm, respectively. The average number of attempts was of 1.22 (0.62). The percentage of visualization of the needle was 74%. The most frequent maneuver used for the correct location, was the modification of the angle of the needle and the relocation of the guidewire in 24% of the cases. The average time for the correct cannulations was 41 (35.8)s. The more frequent complications were the vascular perforation (11.9%) and the correct vascular puncture without possibility of introducing the guidewire (1.2%). The rate of success was 96%. The model simulates the anatomy (vascular and muscular structures) of a pediatric patient. It is cheap models, easily reproducible and a useful tool for training in ultrasound-guided puncture and cannulation. Copyright © 2015 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  3. Ultrasound-guided microwave ablation in the treatment of benign thyroid nodules in 435 patients.

    Science.gov (United States)

    Liu, Yu-Jiang; Qian, Lin-Xue; Liu, Dong; Zhao, Jun-Feng

    2017-09-01

    The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients' clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications.

  4. Routine ultrasound guided evacuation of first trimester missed abortion versus blind evacuation

    OpenAIRE

    Mostafa Abdulla Elsayed

    2014-01-01

    Background: The clinical management of miscarriage has changed little over the years and many women undergo surgical uterine evacuation. Surgical evacuation of the uterine contents in missed abortion is a challenge to the obstetrician as it is done blindly. The current study recommends the use of ultrasound guided surgical evacuation. It serves two important advantages; the first is to complete evacuation without the need of additional step. The second is to protect against uterine perforatio...

  5. Safety of Ultrasound-Guided Botulinum Toxin Injections for Sialorrhea as Performed by Pediatric Otolaryngologists.

    Science.gov (United States)

    Shariat-Madar, Bahbak; Chun, Robert H; Sulman, Cecille G; Conley, Stephen F

    2016-05-01

    To evaluate incidence of complications and hospital readmission as a result of ultrasound-guided botulinum toxin injections to manage sialorrhea. Case series with chart review. Children's Hospital of Wisconsin. A case series with chart review was performed of all cases of ultrasound-guided injection of botulinum toxin by pediatric otolaryngologists from March 5, 2010, to September 26, 2014,. Primary outcomes included complications such as dysphagia, aspiration pneumonia, and motor paralysis. Secondary outcomes included hospitalization, intubation, and nasogastric tube placement. There were 48 patients, 111 interventions, and 306 intraglandular injections identified. Botulinum toxin type A and type B were utilized in 4 and 107 operative interventions, respectively. Type A was injected into 4 parotid and 4 submandibular glands, utilizing doses of 20 U per parotid and 30 U per submandibular gland. Type B was injected into 98 parotid and 200 submandibular glands, with average dosing of 923 U per parotid and 1170 U per submandibular gland, respectively. There were 2 instances of subjectively worsening of baseline dysphagia that self-resolved. No cases were complicated by aspiration pneumonia or motor paralysis. No patients required hospital readmission, intubation, or nasogastric tube placement. Prior published data indicated 16% complication incidence with ultrasound-guided injection of botulinum toxin. Our study found a low complication rate (0.6%) with ultrasound-guided injections of botulinum toxin to manage sialorrhea, without cases of aspiration pneumonia or motor paralysis. Of 306 intraglandular injections, there were 2 cases of worsening baseline subjective dysphagia that self-resolved. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  6. Ultrasound-guided interstitial laser photocoagulation of an autonomous thyroid nodule

    DEFF Research Database (Denmark)

    Døssing, Helle; Bennedbaek, Finn Noe; Hegedüs, Laszlo

    2003-01-01

    effects and often necessitates multiple treatment sessions. We present a case of a 17-year-old female successfully treated with ultrasound (US)-guided percutaneous interstitial laser photocoagulation (ILP) for an AFTN. Initially, she had a serum thyrotropin (TSH) of 0.01 mU/L and normal peripheral thyroid.......9 mL (40% reduction) without further alterations during an additional 9 months of follow-up. Side effects were transient thyrotoxicosis and local pain as seen with PEI. To our knowledge, this is the first reported case of ILP used in a patient with a pretoxic thyroid nodule. US-guided thermic tissue...

  7. Magnetic resonance–guided interstitial high-intensity focused ultrasound for brain tumor ablation

    Science.gov (United States)

    MacDonell, Jacquelyn; Patel, Niravkumar; Rubino, Sebastian; Ghoshal, Goutam; Fischer, Gregory; Burdette, E. Clif; Hwang, Roy; Pilitsis, Julie G.

    2018-01-01

    Currently, treatment of brain tumors is limited to resection, chemotherapy, and radiotherapy. Thermal ablation has been recently explored. High-intensity focused ultrasound (HIFU) is being explored as an alternative. Specifically, the authors propose delivering HIFU internally to the tumor with an MRI-guided robotic assistant (MRgRA). The advantage of the authors’ interstitial device over external MRI-guided HIFU (MRgHIFU) is that it allows for conformal, precise ablation and concurrent tissue sampling. The authors describe their workflow for MRgRA HIFU delivery. PMID:29385926

  8. Palpation- and ultrasound-guided brachial plexus blockade in Hispaniolan Amazon parrots (Amazona ventralis).

    Science.gov (United States)

    da Cunha, Anderson F; Strain, George M; Rademacher, Nathalie; Schnellbacher, Rodney; Tully, Thomas N

    2013-01-01

    To compare palpation-guided with ultrasound-guided brachial plexus blockade in Hispaniolan Amazon parrots. Prospective randomized experimental trial. Eighteen adult Hispaniolan Amazon parrots (Amazona ventralis) weighing 252-295 g. After induction of anesthesia with isoflurane, parrots received an injection of lidocaine (2 mg kg(-1)) in a total volume of 0.3 mL at the axillary region. The birds were randomly assigned to equal groups using either palpation or ultrasound as a guide for the brachial plexus block. Nerve evoked muscle potentials (NEMP) were used to monitor effectiveness of brachial plexus block. The palpation-guided group received the local anesthetic at the space between the pectoral muscle, triceps, and supracoracoideus aticimus muscle, at the insertion of the tendons of the caudal coracobrachial muscle, and the caudal scapulohumeral muscle. For the ultrasound-guided group, the brachial plexus and the adjacent vessels were located with B-mode ultrasonography using a 7-15 MHz linear probe. After location, an 8-5 MHz convex transducer was used to guide injections. General anesthesia was discontinued 20 minutes after lidocaine injection and the birds recovered in a padded cage. Both techniques decreased the amplitude of NEMP. Statistically significant differences in NEMP amplitudes, were observed within the ultrasound-guided group at 5, 10, 15, and 20 minutes after injection and within the palpation-guided group at 10, 15, and 20 minutes after injection. There was no statistically significant difference between the two groups. No effect on motor function, muscle relaxation or wing droop was observed after brachial plexus block. The onset of the brachial plexus block tended to be faster when ultrasonography was used. Brachial plexus injection can be performed in Hispaniolan Amazon parrots and nerve evoked muscle potentials were useful to monitor the effects on nerve conduction in this avian species. Neither technique produced an effective block at the

  9. Ultrasound-guided percutaneous transhepatic biliary drainage: Experiences in 146 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jai Keun [Sohwa Children' s Hospital, Seoul(Korea, Republic of); Yu, Jeong Sik; Kim, Ki Whang; Chung, Soo Yoon; Jeong, Mi Gyoung [Yonsei University College of Medicine, Seoul (Korea, Republic of); Choi, Deuk Lin; Kwon, Gui Hyang; Lee, Hae Kyung [Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    1999-03-15

    Percutaneous biliary drainage is an important technique for palliative therapy of obstructive biliary disease and diagnostic information. The purpose of this study is to review and evaluate the experiences of ultrasound-guided percutaneous transhepatic biliary drainage. Ultrasound-guided percutaneous transhepatic biliary drainage was performed on 146 occasions in 134 patients. The causes of biliary obstruction were: benign diseases (19 cases, 14.2%) such as bile duct stones or stricture, cholangiocarcinoma (37 cases, 27.6%), pancreatic carcinoma (35 cases, 26.1%), metastasis (22 cases, 16.5%), gall bladder cancer (14 cases, 10.4%), ampulla of Vater cancer (4 cases, 3.0%), hepatocellular carcinoma (3 cases, 2.2%). Retrospectively reviewing medical records, we found out frequency of external or external/internal biliary drainages, puncture of left or right hepatic duct, and presence of bileinfection. Ultrasound-guided percutaneous transhepatic biliary drainage was compared with conventional biliary drainage of previous reports on the basis of frequency of complications. External (124 procedures, 84.9%) and external/internal biliary drainage (22 procedures, 15.1%) were carried out by puncture of dilated right (59.6%) or left (40.4%) intrahepatic duct. Sixty-nine complications occurred in 47 patients. Catheter related complications (33/69, 47.8%) were most common: catheter dislodgement (17/69, 24.6%), malfunction (9/69, 13.1%), leakage (7/69, 10.1%). Other minor complications such as simple fever (16/69, 23.2%), cholangitis (7/69, 10.1%), hemobilia (4/69, 5.8%), biloma (2/69, 2.9%) and wound infection (1/69, 1.5%) occurred. Major complications including sepsis (4/69, 5.8%) and bile peritonitis (2/69, 2.9%) were also noted. Puncture-related complications such as hemobilia, biloma and bile peritonitis occurred in 8 cases (5.5%). Comparing with conventional X-ray guided drainage, ultrasound-guided percutaneous transhepatic biliary drainage is a safe procedure for

  10. Ultrasound guided needle biopsy of skeletal muscle in neuromuscular disease

    DEFF Research Database (Denmark)

    Lindequist, S; Schrøder, H D; Larsen, C

    1990-01-01

    Guided by ultrasonography percutaneous needle biopsy of skeletal muscle was performed in 24 patients, using the one hand held Biopty system and a 2 mm Tru-Cut needle. The specimens were graded with regard to diagnostic quality and utility and almost all specimens (96%) were of highest quality. Th....... The use of ultrasonography was helpful in selecting a suitable area for the biopsy and vascular structures could be avoided. The procedure was well tolerated and easy to perform, and no complications were recorded....

  11. Comparison of two ultrasound-guided injection techniques targeting the sacroiliac joint region in equine cadavers.

    Science.gov (United States)

    Stack, John David; Bergamino, Chiara; Sanders, Ruth; Fogarty, Ursula; Puggioni, Antonella; Kearney, Clodagh; David, Florent

    2016-09-20

    To compare the accuracy and distribution of injectate for cranial (CR) and caudomedial (CM) ultrasound-guided injections of equine sacroiliac joints. Both sacroiliac joints from 10 lumbosacropelvic specimens were injected using cranial parasagittal (CR; curved 18 gauge, 25 cm spinal needles) and caudomedial (CM; straight 18 gauge, 15 cm spinal needles) ultrasound-guided approaches. Injectate consisted of 4 ml iodinated contrast and 2 ml methylene blue. Computed tomographical (CT) scans were performed before and after injections. Time for needle guidance and repositioning attempts were recorded. The CT sequences were analysed for accuracy and distribution of contrast. Intra-articular contrast was detected in sacroiliac joints following 15/40 injections. The CR and CM approaches deposited injectate ≤2 cm from sacroiliac joint margins following 17/20 and 20/20 injections, respectively. Median distance of closest contrast to the sacroiliac joint was 0.4 cm (interquartile range [IQR]: 1.5 cm) for CR approaches and 0.6 cm (IQR: 0.95 cm) for CM approaches. Cranial injections resulted in injectate contacting lumbosacral intertransverse joints 15/20 times. Caudomedial injections were perivascular 16/20 times. Safety and efficacy could not be established. Cranial and CM ultrasound-guided injections targeting sacroiliac joints were very accurate for periarticular injection, but accuracy was poor for intra-articular injection. Injectate was frequently found in contact with interosseous sacroiliac ligaments, as well as neurovascular and synovial structures in close vicinity of sacroiliac joints.

  12. Ultrasound-guided percutaneous drainage of meniscal cysts: preliminary clinical experience

    International Nuclear Information System (INIS)

    MacMahon, P.J.; Brennan, D.D.; Duke, D.; Forde, S.; Eustace, S.J.

    2007-01-01

    Aim: To evaluate the efficacy of ultrasound-guided percutaneous drainage of symptomatic meniscal cysts. Materials and methods: Patients with lateral knee joint tenderness and swelling and confirmed meniscal cyst on magnetic resonance imaging (MRI) were consecutively enrolled for ultrasound-guided percutaneous cyst aspiration. Cysts were injected with local anaesthetic and steroid before completion of procedure. All 18 patients (all male, average age 33 years) were subsequently followed up (average time 10 months) and meniscal cyst symptoms assessed by questionnaire. Fischer's exact test used to analyse the data. Results: In every case the procedure was well tolerated, and each patient indicated that they would be willing to have a repeat procedure in the future. Ten patients reported complete resolution of symptoms secondary to therapeutic cyst aspiration and had resumed participation in high-performance sport. Two patients reported a satisfactory sustained response, reporting only occasional 'twinges of pain'. In the remaining six patients, symptoms returned after an initial pain-free period. The pain-free period ranged from 1-8 weeks. In this study, patient outcome did not significantly correlate with any meniscal cyst characteristic. Conclusion: Ultrasound-guided percutaneous aspiration of meniscal cysts is a well-tolerated, simple, and safe procedure. In this small patient series, it was associated with positive early results with favourable outcomes in the mid to long-term. It should be considered in patients unsuitable for surgical debridement or as an interim therapy if surgery is delayed or postponed

  13. In-Plane Ultrasound-Guided Knee Injection Through a Lateral Suprapatellar Approach: A Safe Technique.

    Science.gov (United States)

    Chagas-Neto, Francisco A; Taneja, Atul K; Gregio-Junior, Everaldo; Nogueira-Barbosa, Marcello H

    2017-06-01

    This study aims to describe a technique for in-plane ultrasound-guided knee arthrography through a lateral suprapatellar approach, reporting its accuracy and related complications. A retrospective search was performed for computed tomography and magnetic resonance reports from June 2013 through June 2015. Imaging studies, puncture descriptions, and guided-procedure images were reviewed along with clinical and surgical history. A fellowship-trained musculoskeletal radiologist performed all procedures under sterile technique and ultrasound guidance with the probe in oblique position on the lateral suprapatellar recess after local anesthesia with the patient on dorsal decubitus, hip in neutral rotation, and 30 to 45 degrees of knee flexion. A total of 86 consecutive subjects were evaluated (mean, 55 years). All subjects underwent intra-articular injection of contrast, which was successfully reached in the first attempt in 94.2% of the procedures (81/86), and in the second attempt in 5.8% (5/86) after needle repositioning without a second puncture. There were no postprocedural reports of regional complications at the puncture site, such as significant pain, bleeding, or vascular lesions. Our study demonstrates that in-plane ultrasound-guided injection of the knee in semiflexion approaching the lateral suprapatellar recess is a safe and useful technique to administer intra-articular contrast solution, as an alternative method without radiation exposure.

  14. Outcome of ultrasound-guided small-bore catheter drainage in exudative pleural effusions.

    Science.gov (United States)

    Kiranantawat, Nantaka; Sungsiri, Jitpreedee; Geater, Sarayut L

    2014-05-01

    To evaluate the outcome and safety of ultrasound-guided percutaneous catheter drainage of exudative pleural effusion. The present study was a retrospective analysis of 412 pleural effusions from 373 patients that underwent ultrasound-guided small-bore catheter drainage in exudative pleural effusions between 2004 and 2009. The two most common causes for drainage were parapneumonic effusion or empyema (52.2%) and malignant effusion (30.3%), while the remains were trauma, iatrogenic, and others. Overall clinical success rate was 76.5%. The success rate was lower among malignant pleural effusion (p = 0.003). Causes of effusion were the only independent predictors related to success. Only five (1.2%) patients developed complication during the procedure. Seventy-five of 412 effusions (15.8%) developed complication during the period of drainage; the majority were drain blockage (9%) and accidental dislodgment (4.1%). Ultrasound-guided small-bore catheter drainage was a safe and efficient procedure for exudative pleural effusions.

  15. Diagnostic efficacy of ultrasound-guided core-needle biopsy of peripheral lymph nodes in sarcoidosis.

    Science.gov (United States)

    Boussouar, S; Medjhoul, A; Bernaudin, J F; Tayebjee, O; Soussan, M; Uzunhan, Y; Nunes, H; Kambouchner, M; Martin, A; Valeyre, D; Brillet, P Y

    2015-09-14

    Core-needle biopsy guided by ultrasound can be performed for investigating peripheral lymph node (PLN). The aim of this study was to determine the efficacy of this technique in sarcoidosis. Retrospective review of files of all patients in the database of the radiology department of Avicenne university hospital who underwent PLN biopsies guided by ultrasound from January 2008 to June 2011 (n=292). Cases with either granulomas at histology with the procedure or with a final diagnosis of sarcoidosis were included in the study. The histological specimens were adequate in 282 out of 292 cases (96%) showing non-caseating granulomas in 22 cases (n=20 patients with a final diagnosis of sarcoidosis and n=2 patients with tuberculosis). After reviewing clinical files of the 282 patient, 22 were confirmed to have sarcoidosis, at initial presentation (n=19) or later during flare-up or relapse (n=3) with only 2 patients having no granuloma on PLN biopsy. PLN were palpable in 18 cases and only detected by (18F)FDG-PET/CT showing increased PLN uptake in 4 cases. The sensitivity and specificity of adequate biopsy were 91 and 99% and the positive and negative predictive values were 91 and 99%, respectively. Core-needle biopsy guided by ultrasound has a high efficacy for evidencing granulomas in sarcoidosis patients with PLN involvement either clinically palpable or in the presence of (18F)FDG-PET/CT uptake.

  16. Ultrasound guided electrical impedance tomography for 2D free-interface reconstruction

    Science.gov (United States)

    Liang, Guanghui; Ren, Shangjie; Dong, Feng

    2017-07-01

    The free-interface detection problem is normally seen in industrial or biological processes. Electrical impedance tomography (EIT) is a non-invasive technique with advantages of high-speed and low cost, and is a promising solution for free-interface detection problems. However, due to the ill-posed and nonlinear characteristics, the spatial resolution of EIT is low. To deal with the issue, an ultrasound guided EIT is proposed to directly reconstruct the geometric configuration of the target free-interface. In the method, the position of the central point of the target interface is measured by a pair of ultrasound transducers mounted at the opposite side of the objective domain, and then the position measurement is used as the prior information for guiding the EIT-based free-interface reconstruction. During the process, a constrained least squares framework is used to fuse the information from different measurement modalities, and the Lagrange multiplier-based Levenberg-Marquardt method is adopted to provide the iterative solution of the constraint optimization problem. The numerical results show that the proposed ultrasound guided EIT method for the free-interface reconstruction is more accurate than the single modality method, especially when the number of valid electrodes is limited.

  17. Ultrasound guided electrical impedance tomography for 2D free-interface reconstruction

    International Nuclear Information System (INIS)

    Liang, Guanghui; Ren, Shangjie; Dong, Feng

    2017-01-01

    The free-interface detection problem is normally seen in industrial or biological processes. Electrical impedance tomography (EIT) is a non-invasive technique with advantages of high-speed and low cost, and is a promising solution for free-interface detection problems. However, due to the ill-posed and nonlinear characteristics, the spatial resolution of EIT is low. To deal with the issue, an ultrasound guided EIT is proposed to directly reconstruct the geometric configuration of the target free-interface. In the method, the position of the central point of the target interface is measured by a pair of ultrasound transducers mounted at the opposite side of the objective domain, and then the position measurement is used as the prior information for guiding the EIT-based free-interface reconstruction. During the process, a constrained least squares framework is used to fuse the information from different measurement modalities, and the Lagrange multiplier-based Levenberg–Marquardt method is adopted to provide the iterative solution of the constraint optimization problem. The numerical results show that the proposed ultrasound guided EIT method for the free-interface reconstruction is more accurate than the single modality method, especially when the number of valid electrodes is limited. (paper)

  18. Neuroprotective effects of ultrasound-guided nerve growth factor injections after sciatic nerve injury

    Directory of Open Access Journals (Sweden)

    Hong-fei Li

    2015-01-01

    Full Text Available Nerve growth factor (NGF plays an important role in promoting neuroregeneration after peripheral nerve injury. However, its effects are limited by its short half-life; it is therefore important to identify an effective mode of administration. High-frequency ultrasound (HFU is increasingly used in the clinic for high-resolution visualization of tissues, and has been proposed as a method for identifying and evaluating peripheral nerve damage after injury. In addition, HFU is widely used for guiding needle placement when administering drugs to a specific site. We hypothesized that HFU guiding would optimize the neuroprotective effects of NGF on sciatic nerve injury in the rabbit. We performed behavioral, ultrasound, electrophysiological, histological, and immunohistochemical evaluation of HFU-guided NGF injections administered immediately after injury, or 14 days later, and compared this mode of administration with intramuscular NGF injections. Across all assessments, HFU-guided NGF injections gave consistently better outcomes than intramuscular NGF injections administered immediately or 14 days after injury, with immediate treatment also yielding better structural and functional results than when the treatment was delayed by 14 days. Our findings indicate that NGF should be administered as early as possible after peripheral nerve injury, and highlight the striking neuroprotective effects of HFU-guided NGF injections on peripheral nerve injury compared with intramuscular administration.

  19. Ultrasound guided percutaneous removal of wooden foreign bodies in the extremities with hydro-dissection technique

    Energy Technology Data Exchange (ETDEWEB)

    Park, HeeJin; Lee, So Yeon; Chung, Eun Chul; Rho, Myung Ho [Dept. of Radiology, Sungkyunkwan University School of Medicine, Kangbuk Samsung Hospital, Seoul (Korea, Republic of); Lee, Sung Moon; Son, Eun Seok [Dongsan Medical Center, Keimyung University School of Medicine, Daegu (Korea, Republic of); Lee, Sun Joo [Dept. of Radiology, Inje University College of Medicine, Busan Paik Hospital, Busan (Korea, Republic of)

    2015-12-15

    We described the technique of ultrasound (US)-guided percutaneous removal of the foreign bodies (FB) with hydro-dissection in the radiologic department and presented video files of several cases.Four patients referred to the radiology department for US evaluation and US-guided percutaneous removal of the FBs in the upper and lower extremities between November, 2006 and November, 2013 were included in this study. The procedures started with US evaluation for the exact location and shape of the FB. A 5 mm-sized skin incision was made at the site of the nearest point from the FB where no passing arteries or tendons were present. We adopted a hydro dissection technique to separate the FB from adjacent tissue using a 2% lidocaine solution. Injected anesthetics detached the FBs from surrounding tissue and thereby facilitated removal. After the tip of the mosquito forceps reached the FB, the wooden FBs were removed. The mean time required for the entire procedure was approximately 20 minutes. There were no significant complications during the US-guided removal or long-term complications after the procedure. All 4 FBs were successfully removed from the soft tissue under US guidance. Ultrasound-guided percutaneous removal of the FBs with hydro-dissection in the radiology department is a less invasive and safe method over surgical removal in the operating room. Additionally, the use of a guide wire and serial dilator may help minimize soft tissue injury and facilitate the introduction of forceps.

  20. Difficulties with percutaneous endoscopic gastrostomy (PEG): a practical guide for the endoscopist.

    LENUS (Irish Health Repository)

    O'Mahony, S

    2013-03-01

    Percutaneous endoscopic gastrostomy (PEG) is a widely used and effective means of providing long-term nutrition in patients with inadequate oral intake. The demand for this intervention has risen steadily since the early 1990s. Endoscopists who perform PEG insertion have become increasingly concerned about inappropriate use of this intervention.

  1. Endoscopic Management of Peri-Pancreatic Fluid Collections.

    Science.gov (United States)

    Yip, Hon Chi; Teoh, Anthony Yuen Bun

    2017-09-15

    In the past decade, there has been a progressive paradigm shift in the management of peri-pancreatic fluid collections after acute pancreatitis. Refinements in the definitions of fluid collections from the updated Atlanta classification have enabled better communication amongst physicians in an effort to formulate optimal treatments. Endoscopic ultrasound (EUS)-guided drainage of pancreatic pseudocysts has emerged as the procedure of choice over surgical cystogastrostomy. The approach provides similar success rates with low complications and better quality of life compared with surgery. However, an endoscopic "step up" approach in the management of pancreatic walled-off necrosis has also been advocated. Both endoscopic and percutaneous drainage routes may be used depending on the anatomical location of the collections. New-generation large diameter EUS-specific stent systems have also recently been described. The device allows precise and effective drainage of the collections and permits endoscopic necrosectomy through the stents.

  2. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology

    DEFF Research Database (Denmark)

    Dumonceau, J-M; Polkowski, M; Larghi, A

    2011-01-01

    -TCB), of submucosal tumors, diffuse esophageal/gastric wall thickening, pancreatic solid masses and cystic-appearing lesions, mediastinal lesions unrelated to lung or esophageal cancer, cancer of the esophagus, stomach, and rectum, lymph nodes of unknown origin, adrenal gland masses, and focal liver lesions. False...

  3. Diagnostic Yield and Safety of Endoscopic Ultrasound Guided Fine Needle Aspiration of Central Mediastinal Lung Masses

    Directory of Open Access Journals (Sweden)

    Enrique Vazquez-Sequeiros

    2013-01-01

    Full Text Available Background and Aims. EUS-FNA is an accurate and safe technique to biopsy mediastinal lymph nodes. However, there are few data pertaining to the role of EUS-FNA to biopsy central lung masses. The aim of the study was to assess the diagnostic yield and safety of EUS-FNA of indeterminate central mediastinal lung masses. Methods. Design: Retrospective review of a prospectively maintained database; noncomparative. Setting: Tertiary referral center. From 10/2004 to 12/2010, all patients with a lung mass located within proximity to the esophagus were referred for EUS-FNA. Main Outcome Measurement: EUS-FNA diagnostic accuracy and safety. Results. 73 consecutive patients were included. EUS allowed detection in 62 (85% patients with lack of visualization prohibiting FNA in 11 patients. Among sampled lesions, one patient (1/62 = 1.6% had a benign lung mass (hamartoma, while the remaining 61 patients (61/62 = 98.4% had a malignant mass (primary lung cancer: 55/61 = 90%; lung metastasis: 6/61 = 10%. The sensitivity, specificity, and accuracy of EUS-FNA were 96.7%, 100%, and 96.7%, respectively. The sensitivity was 80.8% when considering nonvisualized masses. One patient developed a pneumothorax (1/62 = 1.6%. Conclusions. EUS-FNA appears to be an accurate and safe technique for tissue diagnosis of central mediastinal lung masses.

  4. Ultrasound-guided facet block to low back pain: a case report

    Directory of Open Access Journals (Sweden)

    Ana Ellen Q. Santiago

    2014-07-01

    Full Text Available BACKGROUND: Osteoarthrosis is a common cause of low back pain. The diagnosis is clinical and can be confirmed by imaging studies. Pain treatment and confirmation of diagnosis are made by intra-articular injection of corticosteroid and by local anesthetic use, due to clinical improvement. A direct monitoring of the procedure can be done under fluoroscopy, a classic technique, or else by an ultrasound-guided procedure. CASE REPORT: Female patient, 88 years old, 1.68 m and 72 kg, with facet osteoarthrosis at L2-L3, L3-L4 and L4-L5 for two years. On physical examination, she exhibited pain on lateralization and spinal extension. We opted in favor of an ultrasound-guided facet joint block. A midline spinal longitudinal scan was obtained, with identification of the desired joint space at L3-L4. A 25 G needle was inserted into the skin by the echographic off-plane ultrasound technique. 1 mL of contrast was administered, with confirmation by fluoroscopy. After aspiration of the contrast, 1 mL of solution containing 0.25% bupivacaine hydrochloride and 10 mg of methylprednisolone acetate was injected. Injections into L3-L4, L2-L3 and L1-L2 to the right were applied. CONCLUSIONS: The visualization of the facet joint by ultrasound involves minimal risk, besides reduction of radiation. This option is suitable for a large part of the population. However, fluoroscopy and computed tomography remain as monitoring techniques indicated for patients with specific characteristics, such as obesity, severe degenerative diseases and anatomical malformations, in which the ultrasound technique is still in need of further study.

  5. Ultrasound-guided pigtail catheters for drainage of various pleural diseases.

    Science.gov (United States)

    Liu, Yi-Heng; Lin, Yu-Chao; Liang, Shinn-Jye; Tu, Chih-Yen; Chen, Chia-Hung; Chen, Hung-Jen; Chen, Wei; Shih, Chuen-Ming; Hsu, Wu-Huei

    2010-10-01

    Little is known about the efficacy and safety of ultrasound-guided pigtail catheters for the management of various pleural diseases in the emergency department, ward, and intensive care unit. We conducted a retrospective study in a university hospital during a 1-year interval. A total of 276 patients (178 men and 98 women) underwent 332 pigtail catheters (the drain size ranged from 10F to 16F) under ultrasound guidance. The mean ± SEM patient age was 59 ± 18 years, and mean duration of drainage was 6.1 ± 2 days. A total of 64 drains (19.2%) were inserted for pneumothoraces; 98 drains (29.5%), for malignant effusions; 119 drains (35.8%), for parapneumonic effusions/empyemas; and 38 drains (11.4%), for massive transudate pleural effusions. The overall success rate was 72.9%. The success rate was highest when the drain was used to treat massive transudate effusions (81.6%) and malignant pleural effusions (75.5%), followed by parapneumonic effusions/empyemas (72.2%), hemothoraces (66.6%), and pneumothoraces (64.0%). Only 10 (3.0%) drains had complications due to the procedure, including infection (n = 4, 1.2%), dislodgment (n = 4, 1.2%), wound bleeding at the pigtail catheter puncture area complicated with hemothoraces (n = 1, 0.3%), and lung puncture (n = 1, 0.3%). There was no significant difference in success rate when different catheter sizes were used to treat pleural diseases. Ultrasound-guided pigtail catheters provide a safe and effective method of draining various pleural diseases. We strongly suggest that ultrasound-guided pigtail catheters be considered as the initial draining method for a variety of pleural diseases. Copyright © 2010 Elsevier Inc. All rights reserved.

  6. Lean Six Sigma Applied to Ultrasound Guided Needle Biopsy in the Head and Neck.

    Science.gov (United States)

    Matt, Bruce H; Woodward-Hagg, Heather K; Wade, Christopher L; Butler, Penny D; Kokoska, Mimi S

    2014-07-01

    (1) Confirm the positive value stream of office-based ultrasound using Lean Six Sigma; (2) demonstrate how ultrasound reduces time to diagnosis, costs, patient inconvenience and travel, exposure to ionizing radiation, intravenous contrast, and laboratory tests. Case series with historical controls using chart review. Tertiary Veterans Administration Hospital (university-affiliated). Patients with a consult request or decision for ultrasound guided fine needle aspiration (USFNA) from 2006 to 2012. Process evaluation using Lean Six Sigma methodologies; years study conducted: 2006-2012; outcome measurements: type of diagnostic tests and imaging studies including CT scans with associated radiation exposure, time to preliminary and final cytopathologic diagnosis, episodes of patient travel. Value stream mapping prior to and after implementing office-based ultrasound confirmed the time from consult request or decision for USFNA to completion of the USFNA was reduced from a range of 0 to 286 days requiring a maximum 17 steps to a range of 0 to 48 days, necessitating only a maximum of 9 steps. Office-based USFNA for evaluation of head and neck lesions reduced costs, time to diagnosis, risks and inconvenience to patients, radiation exposure, unnecessary laboratory, and patient complaints while increasing staff satisfaction. In addition, office-based ultrasound also changed the clinical management of specific patients. Lean Six Sigma reduces waste and optimizes quality and accuracy in manufacturing. This is the first known application of Lean Six Sigma to office-based USFNA in the evaluation of head and neck lesions. The literature supports the value of office-based ultrasound to patients and health care systems. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.

  7. Preliminary study of ergonomic behavior during simulated ultrasound-guided regional anesthesia using a head-mounted display.

    Science.gov (United States)

    Udani, Ankeet D; Harrison, T Kyle; Howard, Steven K; Kim, T Edward; Brock-Utne, John G; Gaba, David M; Mariano, Edward R

    2012-08-01

    A head-mounted display provides continuous real-time imaging within the practitioner's visual field. We evaluated the feasibility of using head-mounted display technology to improve ergonomics in ultrasound-guided regional anesthesia in a simulated environment. Two anesthesiologists performed an equal number of ultrasound-guided popliteal-sciatic nerve blocks using the head-mounted display on a porcine hindquarter, and an independent observer assessed each practitioner's ergonomics (eg, head turning, arching, eye movements, and needle manipulation) and the overall block quality based on the injectate spread around the target nerve for each procedure. Both practitioners performed their procedures without directly viewing the ultrasound monitor, and neither practitioner showed poor ergonomic behavior. Head-mounted display technology may offer potential advantages during ultrasound-guided regional anesthesia.

  8. Contrast-Enhanced Ultrasound Guided Biopsy of Undetermined Abdominal Lesions: A Multidisciplinary Decision-Making Approach

    Directory of Open Access Journals (Sweden)

    Feng Mao

    2017-01-01

    Full Text Available Aim. To investigate the value of contrast-enhanced ultrasound (CEUS guided biopsy of undetermined abdominal lesions in multidisciplinary treatment (MDT decision-making approach. Methods. Between Jan 2012 and Dec 2015, 60 consecutive patients (male, 37; female, 23; mean age, 51.3 years ± 14.6 who presented with undetermined abdominal lesions were included. CEUS and core needle percutaneous biopsy was performed under real-time CEUS guidance in all lesions. Data were recorded and compared with conventional ultrasound (US guidance group (n=75. All CEUS findings and clinical data were evaluated in MDT. Results. CEUS enabled the delimitation of more (88.3% versus 41.3% and larger (14.1 ± 10.7 mm versus 32.3 ± 18.5 mm nonenhanced necrotic areas. More inner (20.0% versus 6.7% and surrounding (18.3% versus 2.7% major vessels were visualized and avoided during biopsies. CEUS-guided biopsy increased the diagnostic accuracy from 93.3% to 98.3%, with correct diagnosis in 57 of 60 lesions (95.0%. The therapeutic plan was influenced by CEUS guided biopsies findings in the majority of patients (98.3%. Conclusion. The combination of CEUS guided biopsy and MDT decision-making approach is useful in the diagnostic work-up and therapeutic management.

  9. Contrast-Enhanced Ultrasound Guided Biopsy of Undetermined Abdominal Lesions: A Multidisciplinary Decision-Making Approach.

    Science.gov (United States)

    Mao, Feng; Dong, Yi; Ji, Zhengbiao; Cao, Jiaying; Wang, Wen-Ping

    2017-01-01

    Aim. To investigate the value of contrast-enhanced ultrasound (CEUS) guided biopsy of undetermined abdominal lesions in multidisciplinary treatment (MDT) decision-making approach. Methods. Between Jan 2012 and Dec 2015, 60 consecutive patients (male, 37; female, 23; mean age, 51.3 years ± 14.6) who presented with undetermined abdominal lesions were included. CEUS and core needle percutaneous biopsy was performed under real-time CEUS guidance in all lesions. Data were recorded and compared with conventional ultrasound (US) guidance group ( n = 75). All CEUS findings and clinical data were evaluated in MDT. Results. CEUS enabled the delimitation of more (88.3% versus 41.3%) and larger (14.1 ± 10.7 mm versus 32.3 ± 18.5 mm) nonenhanced necrotic areas. More inner (20.0% versus 6.7%) and surrounding (18.3% versus 2.7%) major vessels were visualized and avoided during biopsies. CEUS-guided biopsy increased the diagnostic accuracy from 93.3% to 98.3%, with correct diagnosis in 57 of 60 lesions (95.0%). The therapeutic plan was influenced by CEUS guided biopsies findings in the majority of patients (98.3%). Conclusion. The combination of CEUS guided biopsy and MDT decision-making approach is useful in the diagnostic work-up and therapeutic management.

  10. Evolution of Robot-assisted ultrasound-guided breast biopsy systems

    Directory of Open Access Journals (Sweden)

    Mustafa Z. Mahmoud

    2018-01-01

    Full Text Available Robot-assisted ultrasound-guided breast biopsy combines ultrasound (US imaging with a robotic system for medical interventions. This study was designed to provide a literature review of a robotic US-guided breast biopsy system to delineate its efficacious impact on current medical practice. In addition, the strengths and limitations of this approach were also addressed. Articles published in the English language between 2000 and 2016 were appraised in this review. A wide range of systems that bind robotics with US imaging and guided breast biopsy were examined in this article. The fundamental safety and real-time imaging capabilities of US, together with the accuracy and maneuverability of robotic devices, is clearly an effective association with unmatched capabilities. Numerous experimental systems have obvious benefits over old-fashioned techniques, and the future of robot-assisted US-guided breast biopsy will be characterized by increasing levels of automation, and they hold tremendous possibility to impact doctor achievement, patient recovery, and clinical management.

  11. Ultrasound-guided identification of cardiac imaging windows.

    Science.gov (United States)

    Liu, Garry; Qi, Xiu-Ling; Robert, Normand; Dick, Alexander J; Wright, Graham A

    2012-06-01

    Currently, the use of cine magnetic resonance imaging (MRI) to identify cardiac quiescent periods relative to the electrocardiogram (ECG) signal is insufficient for producing submillimeter-resolution coronary MR angiography (MRA) images. In this work, the authors perform a time series comparison between tissue Doppler echocardiograms of the interventricular septum (IVS) and concurrent biplane x-ray angiograms. Our results indicate very close agreement between the diastasis gating windows identified by both the IVS and x-ray techniques. Seven cath lab patients undergoing diagnostic angiograms were simultaneously scanned during a breath hold by ultrasound and biplane x-ray for six to eight heartbeats. The heart rate of each patient was stable. Dye was injected into either the left or right-coronary vasculature. The IVS was imaged using color tissue Doppler in an apical four-chamber view. Diastasis was estimated on the IVS velocity curve. On the biplane angiograms, proximal, mid, and distal regions were identified on the coronary artery (CA). Frame by frame correlation was used to derive displacement, and then velocity, for each region. The quiescent periods for a CA and its subsegments were estimated based on velocity. Using Pearson's correlation coefficient and Bland-Altman analysis, the authors compared the start and end times of the diastasis windows as estimated from the IVS and CA velocities. The authors also estimated the vessel blur across the diastasis windows of multiple sequential heartbeats of each patient. In total, 17 heartbeats were analyzed. The range of heart rate observed across patients was 47-79 beats per minute (bpm) with a mean of 57 bpm. Significant correlations (R > 0.99; p windows. The mean difference in the starting times between IVS and CA quiescent windows was -12.0 ms. The mean difference in end times between IVS and CA quiescent windows was -3.5 ms. In contrast, the correlation between RR interval and both the start and duration of the x

  12. The role of ultrasound and ultrasound-guided fine needle aspiration biopsy of lymph nodes in patients with skin tumours

    International Nuclear Information System (INIS)

    Solivetti, Francesco Maria; Elia, Fulvia; Santaguida, Maria Giulia; Guerrisi, Antonino; Visca, Paolo; Cercato, Maria Cecilia; Di Carlo, Aldo

    2014-01-01

    The primary aim of this study was to evaluate the diagnostic accuracy of ultrasound (US) in the study of superficial lymph nodes during the follow-up of patients surgically treated for skin tumours. The secondary objective was to compare positive cytological results with histological reports. From 2004 to 2011, 480 patients (male/female: 285/195; median age 57 years; prevalent skin tumour: melanoma) underwent US-guided fine-needle aspiration biopsy (FNAB) of suspicious recurrent lymph nodes. An expert radiologist first performed US testing of the lymph nodes, expressing either a negative or positive outcome of the test. Subsequently, US-guided FNAB was performed. FNAB positive patients were subjected to lymphadenectomy; the patients who tested negative underwent the follow-up. The size of lymph nodes was ≤ 2 cm in 90% of cases. Out of the 336 (70%) US “positive” patients, 231 (68.8%) were FNAB positives. Out of the 144 (30%) US “negatives”, 132 (91.7%) were FNAB negatives. The sensitivity and specificity of the US were 95% and 55.7%, respectively; the negative predictive value was 91.7% and the positive predictive value was 68.8%. Definitive histological results confirmed FNAB positivity in 97.5% of lymphadenectomies. US is a sensitive method in the evaluation of superficial lymph nodes during the follow-up of patients with skin tumours. High positive predictive value of cytology was confirmed

  13. Surgical vs ultrasound-guided drainage of deep neck space abscesses: a randomized controlled trial: surgical vs ultrasound drainage.

    Science.gov (United States)

    Biron, Vincent L; Kurien, George; Dziegielewski, Peter; Barber, Brittany; Seikaly, Hadi

    2013-02-26

    Deep neck space abscesses (DNAs) are relatively common otolaryngology-head and neck surgery emergencies and can result in significant morbidity with potential mortality. Traditionally, surgical incision and drainage (I&D) with antibiotics has been the mainstay of treatment. Some reports have suggested that ultrasound-guided drainage (USD) is a less invasive and effective alternative in select cases. To compare I&D vs USD of well-defined DNAs, using a randomized controlled clinical trial design. The primary outcome measure was effectiveness (length of hospital stay (LOHS) and safety), and the secondary outcome measure was overall cost to the healthcare system. Patients presenting to the University of Alberta Emergency Department with a well-defined deep neck space abscess were recruited in the study. Patients were randomized to surgical or US-guided drainage, placed on intravenous antibiotics and admitted with airway precautions. Following drainage with either intervention, abscess collections were cultured and drains were left in place until discharge. Seventeen patients were recruited in the study. We found a significant difference in mean LOHS between patients who underwent USD (3.1 days) vs I&D (5.2 days). We identified significant cost savings associated with USD with a 41% cost reduction in comparison to I&D. USD drainage of deep neck space abscesses in a certain patient population is effective, safe, and results in a significant cost savings to the healthcare system.

  14. Image-guided ultrasound phased arrays are a disruptive technology for non-invasive therapy.

    Science.gov (United States)

    Hynynen, Kullervo; Jones, Ryan M

    2016-09-07

    Focused ultrasound offers a non-invasive way of depositing acoustic energy deep into the body, which can be harnessed for a broad spectrum of therapeutic purposes, including tissue ablation, the targeting of therapeutic agents, and stem cell delivery. Phased array transducers enable electronic control over the beam geometry and direction, and can be tailored to provide optimal energy deposition patterns for a given therapeutic application. Their use in combination with modern medical imaging for therapy guidance allows precise targeting, online monitoring, and post-treatment evaluation of the ultrasound-mediated bioeffects. In the past there have been some technical obstacles hindering the construction of large aperture, high-power, densely-populated phased arrays and, as a result, they have not been fully exploited for therapy delivery to date. However, recent research has made the construction of such arrays feasible, and it is expected that their continued development will both greatly improve the safety and efficacy of existing ultrasound therapies as well as enable treatments that are not currently possible with existing technology. This review will summarize the basic principles, current statures, and future potential of image-guided ultrasound phased arrays for therapy.

  15. Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice.

    Science.gov (United States)

    Scholten, H J; Pourtaherian, A; Mihajlovic, N; Korsten, H H M; A Bouwman, R

    2017-07-01

    Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging structures not visible on the ultrasound screen. Additional techniques specifically developed to aid alignment of needle and probe or identification of the needle tip are now available. In this scoping review, advantages and limitations of the following categories of those solutions are presented: needle guides; alterations to needle or needle tip; three- and four-dimensional ultrasound; magnetism, electromagnetic or GPS systems; optical tracking; augmented (virtual) reality; robotic assistance; and automated (computerised) needle detection. Most evidence originates from phantom studies, case reports and series, with few randomised clinical trials. Improved first-pass success and reduced performance time are the most frequently cited benefits, whereas the need for additional and often expensive hardware is the greatest limitation to widespread adoption. Novice ultrasound users seem to benefit most and great potential lies in education. Future research should focus on reporting relevant clinical parameters to learn which technique will benefit patients most in terms of success and safety. © 2017 The Association of Anaesthetists of Great Britain and Ireland.

  16. WE-H-209-00: Carson/Zagzebski Distinguished Lectureship: Image Guided Ultrasound Therapy

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Focused ultrasound has been shown to be the only method that allows noninvasive thermal coagulation of tissues and recently this potential has been explored for image-guided drug delivery. In this presentation, the advances in ultrasound phased array technology for energy delivery, exposure monitoring and control will be discussed. Experimental results from novel multi-frequency transmit/receive arrays will be presented. In addition, the feasibility of fully electronically focused and steered high power arrays with many thousands of transducer elements will be discussed. Finally, some of the recent clinical and preclinical results for the treatment of brain disease will be reviewed. Learning Objectives: Introduce FUS therapy principles and modern techniques Discuss use of FUS for drug delivery Cover the technology required to deliver FUS and monitor therapy Present clinical examples of the uses of these techniques This research was supported by funding from The Canada Research Chair Program, Grants from CIHR and NIH (no. EB003268).; K. Hynynen, Canada Foundation for Innovation; Canadian Institutes of Health Research; Focused Ultrasound Surgery Foundation; Canada Research Chair Program; Natural Sciences and Engineering Research Council of Canada; Ontario Research Fund; National Institutes of Health; Canadian Cancer Society Research Institute; The Weston Brain Institute; Harmonic Medical; Focused Ultrasound Instruments.

  17. Endoscopic ultrasonography-guided pancreatic duct access: techniques and literature review of pancreatography, transmural drainage and rendezvous techniques.

    Science.gov (United States)

    Itoi, Takao; Kasuya, Kazuhiko; Sofuni, Atsushi; Itokawa, Fumihide; Kurihara, Toshio; Yasuda, Ichiro; Nakai, Yousuke; Isayama, Hiroyuki; Moriyasu, Fuminori

    2013-05-01

    Endoscopic ultrasonography-guided (EUS)-guided pancreatic interventions have gained increasing attention. Here we review EUS-guided pancreatic duct (PD) access techniques and outcomes. EUS-guided PD intervention is divided into two types, antegrade and rendezvous techniques, following EUS-guided pancreatography. In the antegrade technique, pancreaticoenterostomy is carried out by stent placement between the PD and the stomach, duodenum, or jejunum. Transenteric antegrade PD stenting is conducted by stent placement, advancing anteriorly into the PD through the pancreatic tract. The rendezvous technique is carried out by using a guidewire through the papilla or anastomotic site for retrograde stent insertion. In terms of EUS-guided PD stenting, 11 case reports totaling 75 patients (35 normal anatomy, 40 altered anatomy) have been published. The technical success rate was greater than 70%. Early adverse events, including severe hematoma and severe pancreatitis,occurred in seven (63.6%) of 11 reports. Regarding the rendezvous technique, 12 case reports totaling 52 patients (22 normal anatomy, 30 altered anatomy) have been published. The technical success rate ranged from 25% to 100%. It was 48% in one report that involved more than 20 cases. Once stents were placed, all patients became free of symptoms. Early mild adverse events occurred in four (36.4%) of 11 reports. In conclusion, although it can be risky because of possible serious or even fatal adverse events, including pancreatic juice leakage, perforation and severe acute pancreatitis, EUS-PD access seems to be promising for treating symptomatic pancreatic diseases caused by PD stricture and pancreaticoenterostomy stricture. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  18. Steroid injection for painful shoulder: Usefulness of ultrasound-guided approach

    International Nuclear Information System (INIS)

    Lee, Min Hee

    2004-01-01

    To evaluate the efficacy of steroid injection into the subacromial bursa and biceps tendon sheath for painful shoulders and the usefulness of ultrasound-guided approach. Seventeen shoulders of twelve patients with shoulder pain and limited motion were included, and these patient were clinically diagnosed as a painful arc syndrome. Under ultrasound guidance, steroid injection was performed into the subacormial bursa (13 cases) and biceps tendon sheath (4 cases). In 7 cases, 1 mL of steroid was used while the remaining six patients received a mixture of 1 mL of steroid and 1 ml of lidocaine. Both shoulders of two patients received 0.5 mL of steroid. The location of needle and injection duration of fluid were continuously monitored, and complications such as leakage of steroid were recorded. Medical records were reviewed for the presence of pain relief and increasing range of motion following the injection. On ultrasonogram, the needle within the subacromial bursa and biceps tendon sheath was seen as a linear echogenic structure, and injected fluid was identified. There was neither the leakage of steroid injection nor any other complications. In 16 (94%) of 17 shoulders, there was decreased intensity of shoulder pain while increased range of motion was noted in three patients following the injection. Steroid injection into the subacormial bursa and biceps tendon sheath is effective in treating shoulder pain and limited range of motion of the shoulder, and ultrasound is useful guiding method.

  19. Computer tomography urography assisted real-time ultrasound-guided percutaneous nephrolithotomy on renal calculus.

    Science.gov (United States)

    Fang, You-Qiang; Wu, Jie-Ying; Li, Teng-Cheng; Zheng, Hao-Feng; Liang, Guan-Can; Chen, Yan-Xiong; Hong, Xiao-Bin; Cai, Wei-Zhong; Zang, Zhi-Jun; Di, Jin-Ming

    2017-06-01

    This study aimed to assess the role of pre-designed route on computer tomography urography (CTU) in the ultrasound-guided percutaneous nephrolithotomy (PCNL) for renal calculus.From August 2013 to May 2016, a total of 100 patients diagnosed with complex renal calculus in our hospital were randomly divided into CTU group and control group (without CTU assistance). CTU was used to design a rational route for puncturing in CTU group. Ultrasound was used in both groups to establish a working trace in the operation areas. Patients' perioperative parameters and postoperative complications were recorded.All operations were successfully performed, without transferring to open surgery. Time of channel establishment in CTU group (6.5 ± 4.3 minutes) was shorter than the control group (10.0 ± 6.7 minutes) (P = .002). In addition, there was shorter operation time, lower rates of blood transfusion, secondary operation, and less establishing channels. The incidence of postoperative complications including residual stones, sepsis, severe hemorrhage, and perirenal hematoma was lower in CTU group than in control group.Pre-designing puncture route on CTU images would improve the puncturing accuracy, lessen establishing channels as well as improve the security in the ultrasound-guided PCNL for complex renal calculus, but at the cost of increased radiation exposure.

  20. Ultrasound-guided intraarticular injection for MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Schaeffeler, Christoph; Bruegel, M.; Waldt, S.; Rummeny, E.J.; Woertler, K.

    2010-01-01

    Purpose: To evaluate ultrasound guidance for intraarticular contrast injection via an anterolateral approach in comparison with fluoroscopic guidance. Materials and Methods: Contrast agent injection was performed in 40 consecutive patients, 20 under sonographic guidance and 20 under fluoroscopic guidance. None of the patients had previous shoulder surgery. The procedure time was measured and the efficiency of joint distension, incidence of extravasation and intraarticular air on the consecutive MR arthrograms were assessed by three blinded radiologists with musculoskeletal radiology experience. Statistical analysis was performed using the Kruskal-Wallis test. Results: Intraarticular contrast injection was successfully accomplished in all 40 patients. Subsequent MR arthrograms did not show any significant difference between sonographic and fluoroscopic guidance with respect to diagnostic quality, joint distension (p = 0.6665), intraarticular air bubbles (p = 0.1567) and occurrence of contrast extravasation (p = 0.8565). The mean duration of ultrasound-guided injection was 7:30 min compared to a shorter procedure time of 4:15 min for fluoroscopic guidance. In both groups, no procedural complications were observed. Conclusion: Ultrasound-guided injection for MR arthrography of the shoulder via an anterolateral approach represents a simple, safe, and effective technique which yields comparable results to those of injection under fluoroscopic guidance, but is slightly more time-consuming. (orig.)

  1. Feasibility of MRI-guided Focused Ultrasound as Organ-Sparing Treatment for Testicular Cancer

    Science.gov (United States)

    Staruch, Robert; Curiel, Laura; Chopra, Rajiv; Hynynen, Kullervo

    2009-04-01

    High cure rates for testicular cancer have prompted interest in organ-sparing surgery for patients with bilateral disease or single testis. Focused ultrasound (FUS) ablation could offer a noninvasive approach to organ-sparing surgery. The objective of this study was to determine the feasibility of using MR thermometry to guide organ-sparing focused ultrasound surgery in the testis. The testes of anesthetized rabbits were sonicated in several discrete locations using a single-element focused transducer operating at 2.787MHz. Focal heating was visualized with MR thermometry, using a measured PRF thermal coefficient of -0.0089±0.0003 ppm/° C. Sonications at 3.5-14 acoustic watts applied for 30 seconds produced maximum temperature elevations of 10-80° C, with coagulation verified by histology. Coagulation of precise volumes in the testicle is feasible with MRI-guided focused ultrasound. Variability in peak temperature for given sonication parameters suggests the need for online temperature feedback control.

  2. Effectiveness of imaging-guided intra-articular injection: a comparison study between fluoroscopy and ultrasound.

    Science.gov (United States)

    Furtado, Rita Nely Vilar; Pereira, Daniele Freitas; da Luz, Karine Rodrigues; dos Santos, Marla Francisca; Konai, Monique Sayuri; Mitraud, Sonia de Aguiar Vilela; Rosenfeld, Andre; Fernandes, Artur da Rocha Correa; Natour, Jamil

    2013-01-01

    Compare the effectiveness of ultrasound and fluoroscopy to guide intra-articular injections (IAI) in selected cases. A prospective study in our outpatient clinics at the Rheumatology Division at Universidade Federal de São Paulo (UNIFESP), Brazil, was conducted to compare the short-term (4 weeks) effectiveness of ultrasound and fluoroscopy-guided IAI in patients with rheumatic diseases. Inclusion criteria were: adults with refractory synovitis undergoing IAI with glucocorticoid. All patients had IAI performed with triamcinolone hexacetonide (20mg/ml) with varying doses according to the joint injected. A total of 71 rheumatic patients were evaluated (52 women, 44 whites). Mean age was 51.9 ± 13 years and 47 of them (66.2%) were on regular DMARD use. Analysis of the whole sample (71 patients) and hip sub-analysis (23 patients) showed that significant improvement was observed for both groups in terms of pain (P < 0.001). Global analysis also demonstrated better outcomes for patients in the FCG in terms of joint flexion (P < 0.001) and percentage change in joint flexion as compared to the USG. Likert scale score analyses demonstrated better results for the patients in the USG as compared to the FCG at the end of the study (P < 0.05). No statistically significant difference between groups was observed for any other study variable. Imaging-guided IAI improves regional pain in patients with various types of synovitis in the short term. For the vast majority of variables, no significant difference in terms of effectiveness was observed between fluoroscopy and ultrasound guided IAI.

  3. Radiofrequency ablation guided by contrast-enhanced ultrasound for hepatic malignancies: Preliminary results

    International Nuclear Information System (INIS)

    Dong, Y.; Wang, W.-P.; Gan, Y.-H.; Huang, B.-J.; Ding, H.

    2014-01-01

    Aim: To evaluate whether contrast-enhanced ultrasound (CEUS)-guided radiofrequency ablation (RFA) can be performed effectively in small hepatic malignancies that are invisible or poorly visualized at traditional grey-scale ultrasonography (US). Materials and methods: The institutional ethics committee approved the study, and all patients provided written informed consent before their enrolment. The study focused on 55 patients (43 men, 12 women, age 57.4 ± 10.9 years) with 60 hepatic lesions from May 2010 to March 2011. All lesions were treated with multipolar radiofrequency ablation (RFA). During the RFA procedure, with the injection of ultrasound contrast agent (sulphur hexafluoride; SonoVue, Bracco Imaging Spa, Milan, Italy), RFA was conducted under CEUS guidance when the optimal depiction of a lesion was obtained. Artificial pleural effusions were used in those cases obstructed by the lungs. Twenty-four hours after RFA, contrast-enhanced MRI was used as the reference standard to evaluate the primary effectiveness rate and complete tumour necrosis. The follow-up time was 12–24 months (median 15 months). Results: Among 60 hepatic malignancies, CEUS detected 57 lesions (95%), which was higher than that at US (26.6%). Artificial pleural effusions were performed in three cases, resulting in the detection of three additional lesions. The insertion of RFA electrodes was monitored by CEUS in all lesions. Immediately after RFA, complete tumour necrosis were achieved in all 60 lesions as apparent at MRI, for a primary effectiveness rate of 100%. Conclusion: CEUS-guided RFA is a promising technique for targeting and improving the efficiency of treatment of hepatic malignancies. - Highlights: • CEUS guided RFA improved the detectability of hepatic malignancies indistinctive on gray-scale ultrasound. • Pre-operation CEUS helped localization of indistinctive hepatic malignancies. • CEUS guided RFA of hepatic malignancies achieved a more complete ablation

  4. Guided interventions in musculoskeletal ultrasound: what's the evidence?

    Energy Technology Data Exchange (ETDEWEB)

    Davidson, J., E-mail: jdavidson@doctors.org.u [St Richard' s Hospital, Spitalfield Lane, Chichester, West Sussex (United Kingdom); Jayaraman, S. [St Richard' s Hospital, Spitalfield Lane, Chichester, West Sussex (United Kingdom)

    2011-02-15

    Increasing histological and radiological understanding of the processes involved in soft-tissue injury is leading to novel targeted treatments. A number of reviews have recommended that these treatments should be performed with image guidance. This review describes current ultrasound-guided interventions and injections, together with the level of evidence for these. Discussion of guided interventions will include; percutaneous lavage (barbotage), brisement, dry needling, electrocoagulation, and of guided injections; corticosteroids, autologous substances (blood and platelet rich plasma), sclerosants, and prolotherapy (hyperosmolar dextrose). Representative imaging illustrating some of these techniques is included for correlation with the methods described. As these procedures are often performed in sportspeople, it is essential that the radiologist is aware of prohibited substances and methods outlined in an annual publication from the World Anti-Doping Association (WADA). Finally, future directions, including the use of autologous substances, mesenchymal and stem cells will be discussed.

  5. Magnetic Resonance-Guided High-Intensity-Focused Ultrasound for Palliation of Painful Skeletal Metastases: A Pilot Study.

    Science.gov (United States)

    Chan, Michael; Dennis, Kristopher; Huang, Yuexi; Mougenot, Charles; Chow, Edward; DeAngelis, Carlo; Coccagna, Jennifer; Sahgal, Arjun; Hynynen, Kullervo; Czarnota, Gregory; Chu, William

    2017-10-01

    Bone is one of the most common sites of metastases, with bone metastases-related pain representing a significant source of morbidity among patients with cancer. Magnetic resonance-guided focused ultrasound is a noninvasive, outpatient modality with the potential for treating painful bone metastases. The aim of this study is to report our initial experience with magnetic resonance-guided focused ultrasound in the treatment of bone metastases and our preliminary analysis of urinary cytokine levels after therapy. This was a single-center pilot study of 10 patients with metastatic cancer to investigate the feasibility of magnetic resonance-guided focused ultrasound for primary pain control in device-accessible skeletal metastases. Treatments were performed on a clinical magnetic resonance-guided focused ultrasound system using a volumetric ablation technique. Primary efficacy was assessed using Brief Pain Inventory scores and morphine equivalent daily dose intake at 3 time points: before, day 14, and day 30 after the magnetic resonance-guided focused ultrasound treatment. Urine cytokines were measured 3 days before treatment and 2 days after the treatment. Of the 10 patients, 8 were followed up 14 days and 6 were followed up 30 days after the treatment. At day 14, 3 patients (37.5%) exhibited partial pain response and 4 patients (50%) exhibited an indeterminate response, and at day 30 after the treatment, 5 patients (83%) exhibited partial pain response. No treatment-related adverse events were recorded. Of the urine cytokines measured, only Transforming growth factor alpha (TGFα) demonstrated an overall decrease, with a trend toward statistical significance ( P = .078). Our study corroborates magnetic resonance-guided focused ultrasound as a feasible and safe modality as a primary, palliative treatment for painful bone metastases and contributes to the limited body of literature using magnetic resonance-guided focused ultrasound for this clinical indication.

  6. Ultrasound-Guided Versus Landmark-Guided Local Corticosteroid Injection for Carpal Tunnel Syndrome: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.

    Science.gov (United States)

    Babaei-Ghazani, Arash; Roomizadeh, Peyman; Forogh, Bijan; Moeini-Taba, Seyed-Mohammad; Abedini, Amin; Kadkhodaie, Mona; Jahanjoo, Fateme; Eftekharsadat, Bina

    2018-04-01

    To review the literature and assess the comparative effectiveness of ultrasound-guided versus landmark-guided local corticosteroid injections in patients with carpal tunnel syndrome (CTS). Cochrane Central Register of Controlled Trials, MEDLINE (PubMed), Embase (Ovid), and Web of Science (from inception to February 1, 2017). Randomized controlled trials (RCTs) comparing ultrasound-guided injection with landmark-guided injection in patients with CTS were included. Two authors independently screened abstracts and full texts. The outcomes of interest were Symptom Severity Scale (SSS) and Functional Status Scale (FSS) scores of the Boston Carpal Tunnel Questionnaire and 4 electrodiagnostic parameters, including compound muscle action potential (CMAP), sensory nerve action potential (SNAP), distal motor latency (DML), and distal sensory latency (DSL). Overall, 569 abstracts were retrieved and checked for eligibility; finally, 3 RCTs were included (181 injected hands). Pooled analysis showed that ultrasound-guided injection was more effective in SSS improvement (mean difference [MD], -.46; 95% confidence interval [CI], -.59 to -.32; P.99), DML (MD, .05; 95% CI, -.30 to .39; P=.80), or DSL (MD, .00; 95% CI, -.65 to .65; P>.99). This review suggested that ultrasound-guided injection was more effective than landmark-guided injection in symptom severity improvement in patients with CTS; however, no significant differences were observed in functional status or electrodiagnostic improvements between the 2 methods. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  7. Ultrasound-guided Placement of a Foley Catheter Using a Hydrophilic Guide Wire

    Directory of Open Access Journals (Sweden)

    Mark Huber

    2018-03-01

    Full Text Available Acute urinary retention is a common problem in the emergency department. Patients can present in significant distress, necessitating the placement of a urinary catheter. Foley catheter placement can be difficult to accomplish depending on the etiology of the retention and the degree of the obstruction. In the case presented here, we used ultrasound guidance, a guidewire, and a Foley catheter to successfully relieve a patient’s urinary retention after multiple failed attempts.

  8. Endoscopically placed guide wire assisted nasogastric tube insertion for palliation of absolute dysphagia in patients with incurable esophageal cancer

    Directory of Open Access Journals (Sweden)

    Purkayastha Joydeep

    2006-01-01

    Full Text Available Carcinoma of the esophagus is a dreadful disease because it causes a lot of distress to the patient due to its adverse effects on swallowing. Many patients present with large incurable disease or undergo disease progression and become incurable. Such patients are advised palliative and symptomatic care. The most distressing symptom that requires palliation in such patients is dysphagia. Many procedures are available for relief of dysphagia, but these are not readily available or are costly. We describe a simple, safe, cost effective and easy to do procedure for palliation of malignant dysphagia by insertion of Ryle′s tube over a endoscopically placed guide wire especially suitable for patients of the poor socio-economic strata.

  9. Endoluminal ultrasound applicator with an integrated RF coil for high-resolution magnetic resonance imaging-guided high-intensity contact ultrasound thermotherapy

    International Nuclear Information System (INIS)

    Rata, Mihaela; Salomir, Rares; Lafon, Cyril; Umathum, Reiner; Jenne, Juergen; Bock, Michael; Cotton, Francois

    2008-01-01

    High-intensity contact ultrasound (HICU) under MRI guidance may provide minimally invasive treatment of endocavitary digestive tumors in the esophagus, colon or rectum. In this study, a miniature receive-only coil was integrated into an endoscopic ultrasound applicator to offer high-resolution MRI guidance of thermotherapy. A cylindrical plastic support with an incorporated single element flat transducer (9.45 MHz, water cooling tip) was made and equipped with a rectangular RF loop coil surrounding the active element. The integrated coil provided significantly higher sensitivity than a four-element extracorporeal phased array coil, and the standard deviation of the MR thermometry (SDT) improved up to a factor of 7 at 10 mm depth in tissue. High-resolution morphological images (T1w-TFE and IR-T1w-TSE with a voxel size of 0.25 x 0.25 x 3 mm 3 ) and accurate thermometry data (the PRFS method with a voxel size of 0.5 x 0.5 x 5 mm 3 , 2.2 s/image, 0.3 deg. C voxel-wise SDT) were acquired in an ex vivo esophagus sample, on a clinical 1.5T scanner. The endoscopic device was actively operated under automatic temperature control, demonstrating a high level of accuracy (1.7% standard deviation, 1.1% error of mean value), which indicates that this technology may be suitable for HICU therapy of endoluminal cancer.

  10. Endoluminal ultrasound applicator with an integrated RF coil for high-resolution magnetic resonance imaging-guided high-intensity contact ultrasound thermotherapy

    Science.gov (United States)

    Rata, Mihaela; Salomir, Rares; Umathum, Reiner; Jenne, Jürgen; Lafon, Cyril; Cotton, François; Bock, Michael

    2008-11-01

    High-intensity contact ultrasound (HICU) under MRI guidance may provide minimally invasive treatment of endocavitary digestive tumors in the esophagus, colon or rectum. In this study, a miniature receive-only coil was integrated into an endoscopic ultrasound applicator to offer high-resolution MRI guidance of thermotherapy. A cylindrical plastic support with an incorporated single element flat transducer (9.45 MHz, water cooling tip) was made and equipped with a rectangular RF loop coil surrounding the active element. The integrated coil provided significantly higher sensitivity than a four-element extracorporeal phased array coil, and the standard deviation of the MR thermometry (SDT) improved up to a factor of 7 at 10 mm depth in tissue. High-resolution morphological images (T1w-TFE and IR-T1w-TSE with a voxel size of 0.25 × 0.25 × 3 mm3) and accurate thermometry data (the PRFS method with a voxel size of 0.5 × 0.5 × 5 mm3, 2.2 s/image, 0.3 °C voxel-wise SDT) were acquired in an ex vivo esophagus sample, on a clinical 1.5T scanner. The endoscopic device was actively operated under automatic temperature control, demonstrating a high level of accuracy (1.7% standard deviation, 1.1% error of mean value), which indicates that this technology may be suitable for HICU therapy of endoluminal cancer.

  11. Protocol for the realization of transrectal prostatic biopsy guided by ultrasound

    International Nuclear Information System (INIS)

    Arce Montero, Jairo

    2013-01-01

    A general protocol is proposed for the realization of the ultrasound-guided prostatic biopsy in patients with positive screening. The screening should be performed taking into account risk antecedents, rectal examination and prostate-specific antigen (PSA) levels in the patients. However, patients that have presented without alteration in the PSA and suspect rectal examination, should be considered for biopsy endorectal with ultrasound guidance even more with positive risk factors. The generalities of prostate cancer are described. The general prostatic anatomy and echographic are reviewed. The echographic technique is analyzed in the exploration endorectal. The echographic findings suspects of prostate cancer are characterized. The different biopsy sampling techniques are described; and based on appropriate knowledge of prostatic echographic anatomy, could increase the effectiveness in the early detection of prostate cancer in patients with positive screening. The complications derived from the process are enumerated. The final recommendations are noted on the protocol described [es

  12. Learning Ultrasound-Guided Needle Insertion Skills through an Edutainment Game

    Science.gov (United States)

    Chan, Wing-Yin; Ni, Dong; Pang, Wai-Man; Qin, Jing; Chui, Yim-Pan; Yu, Simon Chun-Ho; Heng, Pheng-Ann

    Ultrasound-guided needle insertion is essential in many of minimally invasive surgeries or procedures, such as biopsy, drug delivery, spinal anaesthesia, etc. Accurate and safe needle insertion is a difficult task due to the high requirement of hand-eye coordination skills. Many proposed virtual reality (VR) based training systems put their emphasis on realistic simulation instead of pedagogical efficiency. The lack of schematic training scenario leads to boredom of repetitive operations. To solve this, we present our novel training system with the integration of game elements in order to retain the trainees' enthusiasm. Task-oriented scenarios, time attack scenarios and performance evaluation are introduced. Besides, some state-of-art technologies are also presented, including ultrasound simulation, needle haptic rendering as well as a mass-spring-based needle-tissue interaction simulation. These works are shown to be effective to keep the trainees up with learning.

  13. A novel graphical user interface for ultrasound-guided shoulder arthroscopic surgery

    Science.gov (United States)

    Tyryshkin, K.; Mousavi, P.; Beek, M.; Pichora, D.; Abolmaesumi, P.

    2007-03-01

    This paper presents a novel graphical user interface developed for a navigation system for ultrasound-guided computer-assisted shoulder arthroscopic surgery. The envisioned purpose of the interface is to assist the surgeon in determining the position and orientation of the arthroscopic camera and other surgical tools within the anatomy of the patient. The user interface features real time position tracking of the arthroscopic instruments with an optical tracking system, and visualization of their graphical representations relative to a three-dimensional shoulder surface model of the patient, created from computed tomography images. In addition, the developed graphical interface facilitates fast and user-friendly intra-operative calibration of the arthroscope and the arthroscopic burr, capture and segmentation of ultrasound images, and intra-operative registration. A pilot study simulating the computer-aided shoulder arthroscopic procedure on a shoulder phantom demonstrated the speed, efficiency and ease-of-use of the system.

  14. Ultrasound-guided greater auricular nerve block as sole anesthetic for ear surgery

    Directory of Open Access Journals (Sweden)

    Michael K. Ritchie

    2016-05-01

    Full Text Available A greater auricular nerve (GAN block was used as the sole anesthetic for facial surgery in an 80-year-old male patient with multiple comorbidities which would have made general anesthesia challenging. The GAN provides sensation to the ear, mastoid process, parotid gland, and angle of the mandible. In addition to anesthesia for operating room surgery, the GAN block can be used for outpatient or emergency department procedures without the need for a separate anesthesia team. Although this nerve block has been performed using landmark-based techniques, the ultrasoundguided version offers several potential advantages. These advantages include increased reliability of the nerve block, as well as prevention of inadvertent vascular puncture or blockade of the phrenic nerve, brachial plexus, or deep cervical plexus. The increasing access to ultrasound technology for medical care providers outside the operating room makes this ultrasound guided block an increasingly viable alternative.

  15. Feasibility of ultrasound-guided high intensity focused ultrasound ablating uterine fibroids with hyperintense on T2-weighted MR imaging

    International Nuclear Information System (INIS)

    Zhao, Wen-Peng; Chen, Jin-Yun; Zhang, Lian; Li, Quan; Qin, Juan

    2013-01-01

    Purpose: To retrospectively investigate whether uterine fibroids with hyperintense on pretreatment T2-weighted magnetic resonance imaging (MRI) could be treated with ultrasound-guided high intensity focused ultrasound (USgHIFU). Materials and methods: 282 patients with 282 symptomatic uterine fibroids who underwent USgHIFU treatment were retrospectively analyzed. Based on the signal intensity of T2-weighted MRI, uterine fibroids were classified as hypointense, isointense and hyperintense. Hyperintense fibroids were subjectively further subdivided into heterogeneous hyperintense, slightly homogeneous hyperintense and markedly homogeneous hyperintense based on the signal intensity of fibroid relative to myometrium and endometrium on T2-weighted MRI. Enhanced MRI was performed within one month after HIFU treatment. Non-perfused volume (NPV, indicative of successful ablation) ratio, treatment time, treatment efficiency, energy effect ratio and adverse events were recorded. Results: The median volume of uterine fibroids was 70.3 cm 3 (interquartile range, 41.1–132.5 cm 3 ). The average NPV ratio, defined as non-perfused volume divided by the fibroid volume after HIFU treatment, was 76.8 ± 19.0% (range, 0–100%) in the 282 patients. It was 86.3 ± 11.9% (range, 40.9–100.0%) in the group with hypointense fibroids, 77.1 ± 16.5% (range, 32.2–100.0%) in isointense fibroids, and 67.6 ± 23.9% (range, 0–100.0%) in hyperintense fibroids. The lowest NPV ratio, lowest treatment efficiency, more treatment time, more sonication energy and pain scores were observed in the slightly homogeneous hyperintense fibroids, and the NPV ratio was 55.8 ± 26.7% (range, 0–83.9%) in this subgroup. Conclusion: Based on our results, the heterogeneous and markedly homogeneous hyperintense fibroids were suitable for USgHIFU, and only the slightly homogeneous hyperintense fibroids should be excluded

  16. Effect of adding magnesium sulphate to bupivacaine on the clinical profile of ultrasound-guided thoracic paravertebral block in patients undergoing modified radical mastectomy

    Directory of Open Access Journals (Sweden)

    Mohamed Elsayed Hassan

    2015-01-01

    Conclusion: Adding magnesium sulphate to bupivacaine in ultrasound-guided paravertebral block resulted in more efficient analgesia and opioid-sparing in female patients undergoing modified radical mastectomy.

  17. Contrast ultrasound-guided photothermal therapy using gold nanoshelled microcapsules in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Shumin [Department of Ultrasonography, Peking University Third Hospital, Beijing 100083 (China); Ordos Center Hospital, Ordos, Inner Mongolia 017000 (China); Dai, Zhifei [Department of Biomedical Engineering, College of Engineering, Peking University, Beijing 100871 (China); Ke, Hengte [Nanomedicine and Biosensor Laboratory, School of Life Science and Technology, Harbin Institute of Technology, Harbin 150001 (China); Qu, Enze [Department of Ultrasonography, Peking University Third Hospital, Beijing 100083 (China); Qi, Xiaoxu; Zhang, Kuo [Department of Laboratory Animal Science, Peking University Health Science Center, Beijing 100019 (China); Wang, Jinrui, E-mail: jinrui_wang@sina.com [Department of Ultrasonography, Peking University Third Hospital, Beijing 100083 (China)

    2014-01-15

    Objectives: The purpose of this study was to test whether dual functional gold nano-shelled microcapsules (GNS-MCs) can be used as an ultrasound imaging enhancer and as an optical absorber for photothermal therapy (PTT) in a rodent model of breast cancer. Methods: GNS-MCs were fabricated with an inner air and outer gold nanoshell spherical structure. Photothermal cytotoxicity of GNS-MCs was tested with BT474 cancer cells in vitro and non-obese diabetes-SCID (NOD/SCID) mice with breast cancer. GNS-MCs were injected into the tumor under ultrasound guidance and treated with near-infrared (NIR) laser irradiation. The photothermal ablative effectiveness of GNS-MCs was evaluated by measuring the surface and internal temperature of the tumor as well as the size of the tumor using histological confirmation. Results: NIR laser irradiation resulted in significant tumor cell death in GNS-MCs-treated BT474 cells in vitro. GNS-MCs were able to serve as an ultrasound enhancer to guide the intratumoral injection of GNS-MCs and ensure their uniform distribution. In vivo studies revealed that NIR laser irradiation increased the intratumoral temperature to nearly 70 °C for 8 min in GNS-MCs-treated mice. Tumor volumes decreased gradually and tumors were completely ablated in 6 out of 7 mice treated with GNS-MCs and laser irradiation by 17 days after treatment. Conclusion: This study demonstrates that ultrasound-guided PTT with theranostic GNS-MCs is a promising technique for in situ treatment of breast cancer.

  18. Does ultrasound-guided lidocaine injection improve local anaesthesia before femoral artery catheterization?

    International Nuclear Information System (INIS)

    Spiliopoulos, S.; Katsanos, K.; Diamantopoulos, A.; Karnabatidis, D.; Siablis, D.

    2011-01-01

    Aim: To present the results of a prospective, randomized, single-centre study investigating local anaesthesia before percutaneous common femoral artery (CFA) puncture and catheterization with the use of ultrasound-guided injection of lidocaine versus standard infiltration by manual palpation. Materials and methods: Patients scheduled to undergo diagnostic or therapeutic transfemoral catheter-based procedures gave informed consent and were randomized in two groups. In the first arm local anaesthesia with lidocaine hydrochloride 1% was performed under ultrasound guidance (group U/S), while in the second arm the standard method of manual artery palpation was applied (group M). In both groups, subsequent CFA catheterization was achieved under ultrasound guidance. The primary study endpoint was peri-procedural pain level evaluated with a visual-analogue scale (VAS score 0-10). Results: Between January 2009 and 2010, 200 patients (161 men, mean age 63 ± 12 years) were equally assigned to each group without any significant differences in baseline demographics. Patients in group U/S experienced significantly less pain during CFA catheterization in comparison with group M with a difference of three points in mean VAS score reported (1.6 ± 1.6 versus 4.6 ± 1.9, p < 0.0001). In addition, significantly less volume of lidocaine was used in group U/S compared to group M (16 ± 2.7 versus 19 ± 0.8 ml, p < 0.001).Total vascular access time was similar in both groups (4.4 ± 1.3 versus 4.5 ± 1.3 min). Overall complications included two small groin haematomas in each group. Conclusion: Ultrasound-guided local anaesthesia of the CFA prior to percutaneous transcatheter procedures is safe and achieves superior levels of analgesia with minimal patient pain and discomfort compared to the standard method of manual palpation.

  19. Does ultrasound-guided lidocaine injection improve local anaesthesia before femoral artery catheterization?

    Energy Technology Data Exchange (ETDEWEB)

    Spiliopoulos, S., E-mail: stavspiliop@upatras.g [Department of Diagnostic and Interventional Radiology, Patras University Hospital, School of Medicine, Patras (Greece); Katsanos, K.; Diamantopoulos, A.; Karnabatidis, D.; Siablis, D. [Department of Diagnostic and Interventional Radiology, Patras University Hospital, School of Medicine, Patras (Greece)

    2011-05-15

    Aim: To present the results of a prospective, randomized, single-centre study investigating local anaesthesia before percutaneous common femoral artery (CFA) puncture and catheterization with the use of ultrasound-guided injection of lidocaine versus standard infiltration by manual palpation. Materials and methods: Patients scheduled to undergo diagnostic or therapeutic transfemoral catheter-based procedures gave informed consent and were randomized in two groups. In the first arm local anaesthesia with lidocaine hydrochloride 1% was performed under ultrasound guidance (group U/S), while in the second arm the standard method of manual artery palpation was applied (group M). In both groups, subsequent CFA catheterization was achieved under ultrasound guidance. The primary study endpoint was peri-procedural pain level evaluated with a visual-analogue scale (VAS score 0-10). Results: Between January 2009 and 2010, 200 patients (161 men, mean age 63 {+-} 12 years) were equally assigned to each group without any significant differences in baseline demographics. Patients in group U/S experienced significantly less pain during CFA catheterization in comparison with group M with a difference of three points in mean VAS score reported (1.6 {+-} 1.6 versus 4.6 {+-} 1.9, p < 0.0001). In addition, significantly less volume of lidocaine was used in group U/S compared to group M (16 {+-} 2.7 versus 19 {+-} 0.8 ml, p < 0.001).Total vascular access time was similar in both groups (4.4 {+-} 1.3 versus 4.5 {+-} 1.3 min). Overall complications included two small groin haematomas in each group. Conclusion: Ultrasound-guided local anaesthesia of the CFA prior to percutaneous transcatheter procedures is safe and achieves superior levels of analgesia with minimal patient pain and discomfort compared to the standard method of manual palpation.

  20. SENSITIVITY OF ENDOSCOPIC ULTRASOUND, MULTIDETECTOR COMPUTER TOMOGRAPHY AND MAGNETIC RESONANCE CHOLANGIOPANCREATOGRAPHY IN THE DIAGNOSIS OF PANCREAS DIVISUM: A TERTIARY CENTER EXPERIENCE

    Science.gov (United States)

    Kushnir, Vladimir M.; Wani, Sachin B.; Fowler, Kathryn; Menias, Christine; Varma, Rakesh; Narra, Vamsi; Hovis, Christine; Murad, Faris; Mullady, Daniel; Jonnalagadda, Sreenivasa S.; Early, Dayna S.; Edmundowicz, Steven A.; Azar, Riad R.

    2014-01-01

    OBJECTIVES There are limited data comparing imaging modalities in the diagnosis of pancreas divisum. We aimed to: 1. Evaluate the sensitivity of endoscopic ultrasound (EUS), magnetic resonance cholangiopancreatography (MRCP) and multi-detector computed tomography (MDCT) for pancreas divisum. 2. Assess interobserver agreement (IOA) among expert radiologists for detecting pancreas divisum on MDCT and MRCP. METHODS For this retrospective cohort study, we identified 45 consecutive patients with pancreaticobiliary symptoms and pancreas divisum established by endoscopic retrograde pancreatography (ERP) who underwent EUS and cross-sectional imaging. The control group was composed of patients without pancreas divisum who underwent ERP and cross-sectional imaging. RESULTS The sensitivity of EUS for pancreas divisum was 86.7%, significantly higher than sensitivity reported in the medical records for MDCT (15.5%) or MRCP (60%) [ppancreas divisum; IOA was moderate (қ=0.43). CONCLUSIONS EUS is a sensitive test for diagnosing pancreas divisum and is superior to MDCT and MRCP. Review of MDCT studies by expert radiologists substantially raises its sensitivity for pancreas divisum. PMID:23211370

  1. Ultrasound-guided biopsy of transplanted pancreas: evaluation of 20 cases

    Directory of Open Access Journals (Sweden)

    Marcel Vieira da Nóbrega

    2009-03-01

    Full Text Available Objective: To report the experience with percutaneous biopsies of pancreatic grafts guided by ultrasonography. Methods: Series of cases referred from outpatient’s clinic for biopsy of pancreas transplant, between December 2006 and March 2008. Data were collected from medical electronic records for age, sex and histopathology. The indication for the procedure was obtained from medical and laboratory records. Doppler ultrasonography was performed for control and to guide biopsy in real time. Rresults: Twenty patients referred for biopsy of their transplanted pancreas over a one-year period were evaluated. In one patient, biopsy was not performed for having no safe access for ultrasound. It was used 18 gauge needles, mostly automatic-cut type. The main indications were increased blood glucose and pancreatic enzyme levels as well as reduction of urinary amylase. The sonographic aspect of the pancreatic graft was normal in 18 cases. In all 19 biopsies performed, satisfactory samples for histopathological study were obtained. There were no complications. Cconclusions: This series of cases demonstrated low sensitivity and specificity of ultrasound in diagnosis of pancreatic transplants disorders, but showed to be very useful to guide transplanted pancreas biopsies. Although no complications occurred in this experience, the risk-benefit relation should always be assessed for every patient.

  2. Ultrasound-Guided Multiple Peripheral Nerve Blocks in a Superobese Patient

    Directory of Open Access Journals (Sweden)

    Alper Kilicaslan

    2014-01-01

    Full Text Available The number of obese patients has increased dramatically worldwide. Morbid obesity is associated with an increased incidence of medical comorbidities and restricts the application choices in anesthesiology. We report a successfully performed combined ultrasound-guided blockade of the femoral, tibial, and common peroneal nerve in a superobese patient. We present a case report of a 31-year-old, ASA-PS II, super obese man (190 kg, 180 cm, BMI: 58 kg/m2 admitted to the emergency department with a type II segmental tibia shaft fracture and ankle dislocation after a vehicle accident. After two failed spinal anesthesia attempts, we decided to apply a femoral block combined with a sciatic block. Femoral blocks were successfully performed with US guided in-plane technique. Separate blocks of the tibial and common peroneal nerves were planned after the sciatic nerve could not be located due to the thick subcutaneous tissue. We performed a tibial nerve block at 2 cm above the popliteal crease and common peroneal nerve at the level of the fibular head with US guided in-plane technique. The blocks were successful and no block-related complications were noted. Ultrasound guidance allows new approaches for multiple peripheral nerve blocks with low local anesthetic doses in obese patients.

  3. The effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety.

    Science.gov (United States)

    Hızlı, Fatih; Özcan, Osman; Selvi, İsmail; Eraslan, Pınar; Köşüş, Aydın; Baş, Okan; Yıkılmaz, Taha Numan; Güven, Oğuz; Başar, Halil

    2015-11-01

    Several studies evaluating the tolerance of transrectal ultrasound (TRUS)-guided needle biopsies showed that moderate-to-severe pain was associated with the procedure. Additionally, prebiopsy anxiety or rebiopsy as a result of a prior biopsy procedure is mentioned as factors predisposing to higher pain intensity. Thus, in this study, we investigated the effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety. Sixty-four patients presenting for TRUS-guided prostate needle biopsy were randomly assigned to receive either 10-min presurgery hypnosis session (n = 32, mean age 63.5 ± 6.1, p = 0.289) or a presurgery control session (n = 32, mean age 61.8 ± 6.8, p = 0.289). The hypnosis session involved suggestions for increased relaxation and decreased anxiety. Presurgery pain and anxiety were measured using visual analog scales (VAS), Beck Anxiety Inventory (BAI), and Hamilton Anxiety Scale (HAS), respectively. In our statistics, p < 0.05 was considered statistically significant. Postintervention, and before surgery, patients in the hypnosis group had significantly lower mean values for presurgery VAS [mean 1 (0-8); p = 0.011], BAI (6.0 vs 2.0; p < 0.001), and HAS (11.0 vs 6.0; p < 0.001). The study results indicate that a brief presurgery hypnosis intervention can be an effective means of controlling presurgical anxiety, and therefore pain, in patients awaiting diagnostic prostate cancer surgery.

  4. Individualized laparoscopic B-ultrasound-guided microwave ablation for multifocal primary liver cancer.

    Science.gov (United States)

    Xu, Zhifeng; Yang, Zhangwei; Pan, Jianghua; Hu, Yiren

    2018-03-01

    Liver cancer is one of the most common malignancies of the digestive system. Minimally invasive ablation procedures have become one of the major means for treating unresectable multifocal liver cancer and have been extensively applied in primary and metastatic liver cancer treatment. Laparoscopic B-ultrasound-guided microwave ablation is an example of the progress made in this field. To analyze and summarize the results of and experience with laparoscopic B-ultrasound-guided microwave ablation for multifocal primary liver cancer; moreover, the ablation effects were compared between tumors of different sizes. Laparoscope-guided needle ablation was conducted on 84 lesions from 32 patients with primary liver cancer based on tumor size, quantity, and location. Moreover, the perioperative data, ablation effects according to tumor size, and long-term follow-up results were analyzed. Among the 84 nodules treated via microwave ablation, tumors measuring ≤ 3 cm demonstrated complete ablation upon imaging analysis conducted 1 month after surgery. Moreover, 5 of the tumors measuring > 3 cm demonstrated incomplete ablation. In these cases, a second procedure was performed, until imaging studies confirmed that complete ablation was achieved. Laparoscopic microwave ablation allows for precise puncture positioning, an effective ablation range, and safe and feasible surgery, which is especially suitable for liver tumors located in sites difficult to access.

  5. Real time video processing software for the analysis of endoscopic guided-biopsies

    International Nuclear Information System (INIS)

    Ordoñez, C; Bouchet, A; Pastore, J; Blotta, E

    2011-01-01

    The severity in Barrett esophagus disease is, undoubtedly, the possibility of its malignization. To make an early diagnosis in order to avoid possible complications, it is absolutely necessary collect biopsies to make a histological analysis. This should be done under endoscopic control to avoid mucus areas that may co-exist within the columnar epithelial, which could lead to a false diagnosis. This paper presents a video processing software in real-time in order to delineate and enhance areas of interest to facilitate the work of the expert.

  6. The transabdominal chorionic villus sampling puncture guided by color Doppler ultrasound during early pregnancy

    International Nuclear Information System (INIS)

    Liang Weixiang; Chen Zhiyi; Yuan Wenlin; Cai Kuan; Zhu Junlin; Wang Weiqun; Chen Xia

    2008-01-01

    Objective: To study the operation of chorionic villus sampling (CVS) guided by color Doppler ultrasound (CDU) via abdomen puncture during early pregnancy and investigate the advertences during the operation. Methods: CVS guided by CDU probe via abdomen puncture were operated on 28 pregnant women who had the indications of antenatal diagnosis. CDU was used to observe the implantation position of the fo1iaceous villis and help setting mark of the puncture point and puncture range on body surface before operation. The needle was punctured under real-time ultrasound guidance and villis were aspirated during the operation: The choice of the right time of puncture and the operation skills were emphasized in the study. Results: The CVS puncture approach should be set through CDU ob servation, which attend to avoid the surrounding blood vessels, intestinal canal and surrounding important organs. The puncture point should be chosen in a point where lobif0rmed villis distributed wider and with a larger scope. The operations were performed from 10 to13 weeks of pregnancy, with an average of 11 weeks. Among these 28 cases, 9.6 were successfully drawn materials in one time, 1 in twice and l failure, with the total ratio of achievement was 96.4%. For all the cases, fetal heart pulsating could be seen by real-time CDU observation fight after the operation, and no larger hematoma echo in the placental site occurred. Ultrasound reexamined one week after the operation, fetal heart pulsation could be found in all cases, and no abortion cases occurred after regular follow-up in 25 continued pregnant patients. Conclusion: Abdominal CVS puncture guided by CDU probe is conveniently operated, safe and available in clinic. It is an important method for antenatal diagnosis during early pregnancy. The puncture localization, skills and the time are the key points for the success in obtaining the materials. (authors)

  7. Analgesic efficacy of the ultrasound-guided blockade of the transversus abdominis plane - a systematic review

    Directory of Open Access Journals (Sweden)

    Javier Ripollés

    2015-08-01

    Full Text Available BACKGROUND: The transverse abdominal plan blockade is a block of abdominal wall that has diffused rapidly in the clinical practice as part of a multimodal analgesia for abdominal surgery. The performance of the ultrasound-guided technique has allowed the lowering of potential complications, as well as new approaches that were carried out according to the descriptions, and the prospective studies would make it possible to utilize the transverse abdominal plan blockade in different surgical interventions; however, the results obtained in randomized clinical trials are inconsistent.OBJECTIVES: To prepare a systematic review aiming to determine the efficacy of the ultrasound-guided transverse abdominal plan blockade for different surgical interventions, as well as the indications according to the approaches and their influences.METHODS: Two research approaches, one manual, and the other in Pubmed returned 28 randomized clinical trials where intervention with ultrasound-guided transverse abdominal plan blockades was performed to compare the analgesic efficacy in contrast to another technique in adults, published between 2007 and October 2013, in English or Spanish, with Jadad score > 1, according to the inclusion criteria for this review. The authors analyzed independently all the randomized clinical trials.CONCLUSIONS: The transverse abdominal plan blockades have been shown to be an effective technique in colorectal surgery, cesarean section, cholecystectomy, hysterectomy, appendectomy, donor nephrectomy, retropubic prostatectomy, and bariatric surgery. However, the data found in randomized clinical trial are not conclusive, and as a result, it is necessary to develop new and well designed randomized clinical trial, with enough statistical power to compare different approaches, drugs, doses, and volumes for the same intervention, aiming to answer the current questions and their effects in the habitual clinical practice.

  8. Ultrasound guided percutaneous treatment and follow-up of Baker's cyst in knee osteoarthritis

    International Nuclear Information System (INIS)

    Köroğlu, Mert; Çallıoğlu, Mehmet; Eriş, Hüseyin Naim; Kayan, Mustafa; Çetin, Meltem; Yener, Mahmut; Gürses, Cemil; Erol, Bekir; Türkbey, Barış; Parlak, Ayşe Eda; Akhan, Okan

    2012-01-01

    Objective: Purpose of this study is to assess sonographic changes and clinical response in different subgroups of Baker's cyst patients with knee osteoarthritis after a single session of ultrasound-guided percutaneous aspiration and corticosteroid injection. Materials and methods: Thirty-two knee osteoarthritis patients (46–85 years, mean 58.97 ± 9.88) with symptomatic Baker's cyst diagnosed at ultrasonography were included in the study. To determine the grade of the symptoms, Visual Analogue Scale was applied. The patients were grouped in two, as simple (n = 24) and complex (n = 8) Baker's cyst. Thirty-two ultrasound-guided cyst aspirations concomitant 1 ml betamethasone injection (24 simple, 8 complex subgroups) were performed. Patients were followed clinically as well as via ultrasonography for 6 months after procedures. Results: A significant decrease in volume of the Baker's cysts after percutaneous treatment was accompanied by a significant clinical improvement. Moreover, the volume reduction of Baker's cyst after the treatment was significantly correlated with the clinical improvement (Pearson correlation coefficient = 0.542, p = 0.001). All 6 Baker's cysts relapsed at ultrasonography were complex type. Furthermore, a comparison of patients with simple Baker's cysts and those with complex Baker's cysts demonstrated no significant change in Visual Analogue Scale scores between two groups (p = 0.061, Mann–Whitney U). No complications (minor or major) occurred secondary to percutaneous treatment. Conclusion: Baker's cysts can be grouped as simple and complex groups via ultrasonography prior to the treatment. Cyst aspiration with ultrasound-guided corticosteroid injection yields clinical improvement and cyst volume reduction in all subgroups of patients with Baker's cyst secondary to knee osteoarthritis.

  9. A comparison of ultrasound guided fine needle aspiration cytology and core needle biopsy in evaluation of palpable breast lesions

    International Nuclear Information System (INIS)

    Altaf, H.N.; Farooqui, F.

    2015-01-01

    Objective: To compare ultrasound guided fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients presenting with palpable breast lumps (PBLs), in terms of sensitivity and specificity, taking final histopathology as gold standard. Methodology: This cross-sectional study was conducted at Holy Family Hospital, Rawalpindi, Pakistan. Ultrasound guided FNAC and CNB were taken of all female patients with PBLs. The results were compared with final histopathology as gold standard. Data analysis was performed using SPSS software and chi-square test. Results: A total of 60 patients were included in the study. The mean age was 33.8 yrs. The sensitivity and specificity of ultrasound guided FNAC were 68.7% and 93.1%, respectively. The sensitivity and specificity of ultrasound guided CNB was 93.7% and 100%. The accuracy of FNAC was 86.2% and that of core needle biopsy was 98.3%. Conclusion: The ultrasound guided core needle biopsy can be used as an initial diagnostic test for the evaluation of all PBLs. Because of high negative predictive value core needle biopsy can replace surgical excision biopsy for benign lesions. (author)

  10. Noninvasive treatment of focal adenomyosis with MR-guided focused ultrasound in two patients

    International Nuclear Information System (INIS)

    Polina, Laveena; Nyapathy, Vinay; Mishra, Anindita; Yellamanthili, Himabindu; Vallabhaneni, Mythri P

    2012-01-01

    Adenomyosis is a common benign gynecological disorder presenting with dysmenorrhea, menorrhagia, and pressure symptoms. Magnetic resonance imaging–guided focused ultrasound surgery (MRgFUS) utilizes precisely focused USG waves to generate and maintain high temperatures within the targeted tissue to achieve protein denaturation and coagulative necrosis. The heat generated is monitored using MRI images acquired in real-time in three planes. We present two cases of focal adenomyosis treated with MRgFUS showing good symptomatic relief at 3 and 6 months follow-up

  11. Ultrasound-guided sclerotherapy for benign non-thyroid cystic mass in the neck

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Hoon [Dept. of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2014-04-15

    Surgical excision has traditionally been the treatment of choice for benign non-thyroid cystic neck masses, including lymphatic malformation, ranula, branchial cleft cyst, thyroglossal duct cyst, and parathyroid cyst. However, there is a tendency toward recurrence after surgery, and surgery may be accompanied by complications, including nerve injuries, vascular injuries, and scar formation. Ultrasound-guided sclerotherapy using various agents has been challenged and successfully applied as an alternative treatment for benign non-thyroid cystic neck masses. This report reviews the available sclerosing agents and describes the applications of sclerotherapy to the treatment of benign cystic masses in the neck.

  12. Ultrasound-guided sclerotherapy for benign non-thyroid cystic mass in the neck

    Directory of Open Access Journals (Sweden)

    Ji-hoon Kim

    2014-04-01

    Full Text Available Surgical excision has traditionally been the treatment of choice for benign non-thyroid cystic neck masses, including lymphatic malformation, ranula, branchial cleft cyst, thyroglossal duct cyst, and parathyroid cyst. However, there is a tendency toward recurrence after surgery, and surgery may be accompanied by complications, including nerve injuries, vascular injuries, and scar formation. Ultrasound-guided sclerotherapy using various agents has been challenged and successfully applied as an alternative treatment for benign non-thyroid cystic neck masses. This report reviews the available sclerosing agents and describes the applications of sclerotherapy to the treatment of benign cystic masses in the neck.

  13. Ultrasound-guided sclerotherapy for benign non-thyroid cystic mass in the neck

    International Nuclear Information System (INIS)

    Kim, Ji Hoon

    2014-01-01

    Surgical excision has traditionally been the treatment of choice for benign non-thyroid cystic neck masses, including lymphatic malformation, ranula, branchial cleft cyst, thyroglossal duct cyst, and parathyroid cyst. However, there is a tendency toward recurrence after surgery, and surgery may be accompanied by complications, including nerve injuries, vascular injuries, and scar formation. Ultrasound-guided sclerotherapy using various agents has been challenged and successfully applied as an alternative treatment for benign non-thyroid cystic neck masses. This report reviews the available sclerosing agents and describes the applications of sclerotherapy to the treatment of benign cystic masses in the neck.

  14. Ultrasound-Guided real-time pterygopalatine block for analgesia in an oral cancer patient

    Directory of Open Access Journals (Sweden)

    Nishkarsh Gupta

    2018-01-01

    Full Text Available Oral cancers are one of the most common cancers in India. These patients have pain during the course of the disease. Various drugs including opioid and nonsteroidal anti-inflammatory drug have been used to manage pain. However, these are associated with side effects such as constipation and vomiting. An early interventional block may decrease the requirement for analgesics and improve the overall quality of life. We describe a case of oral carcinoma successfully managed with ultrasound-guided pterygopalatine block.

  15. Magnetic resonance guided focalized ultrasound thermo-ablation: A promising oncologic local therapy

    International Nuclear Information System (INIS)

    Iannessi, A.; Doyen, J.; Leysalle, A.; Thyss, A.

    2014-01-01

    Pain management of bone metastases is usually made using systemic and local therapy. Even though radiations are nowadays the gold standard for painful metastases, innovations regarding minimally invasive treatment approaches have been developed because of the existing non-responder patients [1]. Indeed, cementoplasty and thermo-ablations like radiofrequency or cryotherapy have shown to be efficient on pain [2-4]. Among thermo-therapy, magnetic resonance guided focalized ultrasound is now a new non-invasive weapon for bone pain palliation. (authors)

  16. The advent of ultrasound-guided ablation techniques in nodular thyroid disease

    DEFF Research Database (Denmark)

    Papini, Enrico; Pacella, Claudio M; Misischi, Irene

    2014-01-01

    non-functioning thyroid nodules that grow or become symptomatic, trained operators may safely induce, with a single session of laser ablation treatment or radiofrequency ablation, a 50% volume decrease and, in parallel, improve local symptoms. In contrast, hyperfunctioning nodules remain best treated...... minimally invasive treatments, directed towards office-based management of symptomatic nodules, without requiring general anaesthesia, and with negligible damage to the skin and cervical tissues, have been proposed during the past two decades. Today, ultrasound-guided percutaneous ethanol injection...

  17. NMR guided focused ultrasound for myoma therapy - results from the first radiology-gynecology expert meeting

    International Nuclear Information System (INIS)

    Beck, A.; Charite Universitaetsmedizin Berlin, Campus Virchow-Klinikum, Berlin; David, M.; Kroencke, T.; Charite Universitaetsmedizin Berlin, Campus Charite Mitte, Berlin

    2013-01-01

    The contribution on the results from the first radiology-gynecology expert meeting concerning NMR guided focused ultrasound (MRgFUS) for myoma therapy covers the following topics: structural prerequisites for MRgFUS therapy; required examinations before MRgFUS therapy; indication for MRgFUS therapy; success criteria for the MRgFUS therapy; contraindications; MRgFUS therapy for patients that want to have children; side effects and complications of MRgFUS therapy; post-examination after MRgFUS therapy.

  18. Percutaneous cryoablation of prostate cancer guided by rectal ultrasound: a retrospectively analysis of 42 cases

    International Nuclear Information System (INIS)

    Xing Wenge; Guo Zhi; Wang Haitao; Liu Fang; Li Baoguo; Yu Haipeng; Li Yong

    2008-01-01

    Objective: To evaluate the effectiveness and safety of rectal ultrasound-guided agon-hilium percutaneous cryoablation in treatment of patients with median and or late-stage prostate cancer patients. Methods: Retrospectively analysis of 42 cases of with stage C and D prostate cancer patients treated by rectal ultrasound-guided argon-hilium percutaneous cryoablation during the follow-up of 1-12 months. The prostate specific antigen (PSA), biochemical progression-free survival (bPFS), PSA objective response, transrectal ultrasound of the prostate (TRUS), TRUS-guided biopsy of the prostate, the maximum urinary flow rate(MFR), MRI examination at before, and 3,6,12 months after cryoablation were recorded and evaluated. The results were statistically evaluated by using variance analysis. Results: The PSA value at before and 3,6, 12 months after cryoablation were (4.48±1.35), (3.54±1.67), (3.18±1.76), (2.87±1.89) μg/L, respectively; TRUS-measured prostate volumes at before and 3, 6,12 months after cryoablation were (59.7± 8.2), (46.9±8.3), (26.2±3.9), (25.9±3.7) mm 3 , respectively; MFR before and 3, 6,12 months after cryoablation were (10.4±0.8), (14.3±1.2), (18.3±1.3), (18.9±1.3) ml/s, respectively; Compared with before cryoablation, the differences between before and after cryoablation was statistically significant (F= 53.93,747.92,3843.03, respectively, P<0.01). The bPFS rates in 3 months,6 months and 12 months were 95.2% (40/42), 95.2% (40/42), and 90.5% (38/42), respectively. According to the PSA response, the total effective rate (CR 16 cases, PR 15 cases) at 12 months was 73.8%, and SD was 16.7% (7/42), PD was 9.5% (4/42). Complications included temporary incontinence 2.4% (1/42), Penile tingling/numbness 2.4% (1/42), pelvic pain 4.9% (2/41) and Scrotum Edema 2.4% (1/42). There was no case with severe complications such as severe infection or urethrorectal fistula, etc. Conclusions: Rectal ultrasound-guided agon-hilium percutaneous cryoablation showed

  19. Ultrasound-Guided Intermediate Site Greater Occipital Nerve Infiltration: A Technical Feasibility Study.

    Science.gov (United States)

    Zipfel, Jonathan; Kastler, Adrian; Tatu, Laurent; Behr, Julien; Kechidi, Rachid; Kastler, Bruno

    2016-01-01

    Two studies recently reported that computed tomography (CT) guided infiltration of the greater occipital nerve at its intermediate site allows a high efficacy rate with long-lasting pain relief following procedure in occipital neuralgia and in various craniofacial pain syndromes. The purpose of our study was to evaluate the technical feasibility and safety of ultrasound-guided intermediate site greater occipital nerve infiltration. Retrospective study. This study was conducted at the imaging department of a 1,409 bed university hospital. Local institutional review board approval was obtained and written consent was waived. In this retrospective study, 12 patients suffering from refractory occipital neuralgia or craniofacial pain syndromes were included between April and October 2014. They underwent a total of 21 ultrasound-guided infiltrations. Infiltration of the greater occipital nerve was performed at the intermediate site of the greater occipital nerve, at its first bend between obliqus capitis inferior and semispinalis capitis muscles with local anestetics and cortivazol. Technical success was defined as satisfactory diffusion of added iodinated contrast media in the fatty space between these muscles depicted on control CT scan. We also reported first data of immediate block test efficacy and initial clinical efficacy at 7 days, one month, and 3 months, defined by a decrease of at least 50% of visual analog scale (VAS) scores. Technical success rate was 95.24%. Patients suffered from right unilateral occipital neuralgia in 3 cases, left unilateral occipital neuralgia in 2 cases, bilateral occipital neuralgia in 2 cases, migraine in one case, cervicogenic headache in one case, tension-type headache in 2 cases, and cluster headache in one case. Block test efficacy was found in 93.3% (14/15) cases. Clinical efficacy was found in 80% of cases at 7 days, in 66.7% of cases at one month and in 60% of cases at 3 months. No major complications were noted. Some of the

  20. Ultrasound

    Science.gov (United States)

    ... completed. Young children may need additional preparation. When scheduling an ultrasound for yourself or your child, ask ... of Privacy Practices Notice of Nondiscrimination Manage Cookies Advertising Mayo Clinic is a not-for-profit organization ...

  1. Ultrasound

    Science.gov (United States)

    ... reflect off body structures. A computer receives the waves and uses them to create a picture. Unlike with an x-ray or CT scan, this test does not use ionizing radiation. The test is done in the ultrasound ...

  2. Is ultrasound-guided injection more effective in chronic subacromial bursitis?

    Science.gov (United States)

    Hsieh, Lin-Fen; Hsu, Wei-Chun; Lin, Yi-Jia; Wu, Shih-Hui; Chang, Kae-Chwen; Chang, Hsiao-Lan

    2013-12-01

    Although ultrasound (US)-guided subacromial injection has shown increased accuracy in needle placement, whether US-guided injection produces better clinical outcome is still controversial. Therefore, this study aimed to compare the efficacy of subacromial corticosteroid injection under US guidance with palpation-guided subacromial injection in patients with chronic subacromial bursitis. Patients with chronic subacromial bursitis were randomized to a US-guided injection group and a palpation-guided injection group. The subjects in each group were injected with a mixture of 0.5 mL dexamethasone suspension and 3 mL lidocaine into the subacromial bursa. The primary outcome measures were the visual analog scale for pain and active and passive ranges of motion of the affected shoulder. Secondary outcome measures were the Shoulder Pain and Disability Index, the Shoulder Disability Questionnaire, and the 36-item Short-Form Health Survey (SF-36). The primary outcome measures were evaluated before, immediately, 1 wk, and 1 month after the injection; the secondary outcome measures were evaluated before, 1 wk, and 1 month after the injection. Of the 145 subjects screened, 46 in each group completed the study. Significantly greater improvement in passive shoulder abduction and in physical functioning and vitality scores on the SF-36 were observed in the US-guided group. The pre- and postinjection within-group comparison revealed significant improvement in the visual analog scale for pain and range of motion, as well as in the Shoulder Pain and Disability Index, Shoulder Disability Questionnaire, and SF-36 scores, in both groups. The US-guided subacromial injection technique produced significantly greater improvements in passive shoulder abduction and in some items of the SF-36. US is effective in guiding the needle into the subacromial bursa in patients with chronic subacromial bursitis.

  3. The Role of Endoscopic Ultrasound in the Diagnostic Assessment of Subepithelial Lesions of the Upper Gastrointestinal Tract

    Directory of Open Access Journals (Sweden)

    Francisca Dias de Castro

    2016-11-01

    Conclusion: EUS is the method of choice in the study of subepithelial lesions of the upper gastrointestinal tract, in most cases defining a diagnosis. The need for a definitive diagnosis or therapeutic approaches can be based on ultrasound risk features, presented, in the majority, at presentation. This study shows that EUS is capable of safely and accurately define those subepithelial lesions that can be managed only with surveillance ultrasound while waiting for better results with fine needle aspiration.

  4. Long-term results after endoscopic drainage and necrosectomy of symptomatic pancreatic fluid collections.

    Science.gov (United States)

    Seewald, Stefan; Ang, Tiing Leong; Richter, Hugo; Teng, Karl Yu Kim; Zhong, Yan; Groth, Stefan; Omar, Salem; Soehendra, Nib

    2012-01-01

    To determine the immediate and long-term results of endoscopic drainage and necrosectomy for symptomatic pancreatic fluid collections. The data of 80 patients with symptomatic pancreatic fluid collections (mean diameter: 11.7 cm, range 3-20; pseudocysts: 24/80, abscess: 20/80, infected walled-off necrosis: 36/80) referred for endoscopic management from October 1997 to March 2008 were analyzed retrospectively. Endoscopic drainage techniques included endoscopic ultrasound (EUS)-guided aspiration (2/80), EUS-guided transenteric drainage (70/80) and non-EUS-guided drainage across a spontaneous transenteric fistula (8/80). Endoscopic necrosectomy was carried out in 49/80 (abscesses: 14/20; infected necrosis: 35/36). Procedural complications were bleeding (12/80), perforation (7/80), portal air embolism (1/80) and Ogilvie Syndrome (1/80). Initial technical success was achieved in 78/80 (97.5%) and clinical resolution of the collections was achieved endoscopically in 67/80 (83.8%), with surgery required in 13/80 (perforation: four; endoscopically inaccessible areas: two; inadequate drainage: seven). Within 6 months five patients required surgery due to recurrent fluid collections; over a mean follow up of 31 months, surgery was required in four more patients due to recurrent collections as a consequence of underlying pancreatic duct abnormalities that could not be treated endoscopically. The long-term success of endoscopic treatment was 58/80 (72.5%). Endoscopic drainage of symptomatic pancreatic fluid collections is safe and effective, with excellent immediate and long-term results. Endoscopic necrosectomy has a risk of serious complications. The underlying pancreatic duct abnormalities must be addressed to prevent recurrence of fluid collections. © 2011 The Authors. Digestive Endoscopy © 2011 Japan Gastroenterological Endoscopy Society.

  5. Ultrasound-Guided Percutaneous Electrolysis and Eccentric Exercises for Subacromial Pain Syndrome: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    José L. Arias-Buría

    2015-01-01

    Full Text Available Objective. To compare effects of ultrasound- (US- guided percutaneous electrolysis combined with an eccentric exercise program of the rotator cuff muscles in subacromial pain syndrome. Methods. Thirty-six patients were randomized and assigned into US-guided percutaneous electrolysis (n=17 group or exercise (n=19 group. Patients were asked to perform an eccentric exercise program of the rotator cuff muscles twice every day for 4 weeks. Participants assigned to US-guided percutaneous electrolysis group also received the application of galvanic current through acupuncture needle on each session once a week (total 4 sessions. Shoulder pain (NPRS and disability (DASH were assessed at baseline, after 2 sessions, and 1 week after the last session. Results. The ANOVA revealed significant Group∗Time interactions for shoulder pain and disability (all, P<0.01: individuals receiving US-guided percutaneous electrolysis combined with the eccentric exercises experienced greater improvement than those receiving eccentric exercise alone. Conclusions. US-guided percutaneous electrolysis combined with eccentric exercises resulted in small better outcomes at short term compared to when only eccentric exercises were applied in subacromial pain syndrome. The effect was statistically and clinically significant for shoulder pain but below minimal clinical difference for function. Future studies should investigate the long-term effects and potential placebo effect of this intervention.

  6. The role of ultrasound-guided vacuum-assisted removal of gynecomastia

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Me [Dankook University Hospital, Cheonan (Korea, Republic of)

    2008-02-15

    To evaluate the role of performing ultrasound (US)-guided vacuum-assisted breast biopsies for the treatment (mammotome excision) of gynecomastia. Between November 2005 and December 2006, nine male patients underwent US-guided mammotome excision for eleven cases of true gynecomastia. The patient ages ranged from 14 to 55 years (mean age, 32.3 years). US-guided mammotome excision was performed with an 11-gauge needle in seven cases and an 8-gauge needle in four cases. After the procedure, the cigarette method using gauze packing was performed. The number of samples, procedure time and presence of complications were evaluated. Scheduled follow-up physical and US examinations were performed after three and six months. For 11 cases of US-guided mammotome excision of gynecomastia, the number of samples ranged from 12-126 (mean, 66) and the procedure time ranged from 10-42 minutes (mean time, 25.1 minutes). Clinical significant complications did not occur immediately after the procedure and complications were not seen after a follow-up examination in any of the cases. At the 3-and 6-month follow up examinations, all of the patients showed a normal male physical appearance on a physical examination and there was no evidence of hypoechoic glandular tissues as seen on ultrasonograms. US-guided mammotome excision is effective for the treatment of small, glandular true gynecomastia and is suggested as a new modality to replace the need for surgery or liposuction.

  7. Case report: ultrasound-guided continuous thoracic paravertebral block for outpatient acute pain management of multilevel unilateral rib fractures.

    Science.gov (United States)

    Murata, Hiroaki; Salviz, Emine Aysu; Chen, Stephanie; Vandepitte, Catherine; Hadzic, Admir

    2013-01-01

    A 61-year-old man with multiple unilateral rib fractures (T3-T8) gained the ability to breathe deeply and to ambulate after ultrasound-guided continuous thoracic paravertebral block and was discharged home after being observed for 15 hours after the block. The ultrasound guidance was helpful in determining the site of rib fractures and the optimal level for catheter placement. This report also discusses the management of analgesia using continuous paravertebral block in an outpatient with trauma.

  8. Economic analysis of combined endoscopic and endobronchial ultrasound in the evaluation of patients with suspected non-small cell lung cancer.

    LENUS (Irish Health Repository)

    Harewood, Gavin C

    2010-03-01

    Lung cancer remains the most common cause of cancer-related death in the United States. This study evaluated the costs of alternative diagnostic evaluations for patients with suspected non-small cell lung cancer (NSCLC). Researchers used a cost-minimization model to compare various diagnostic approaches in the evaluation of patients with NSCLC. It was less expensive to use an initial endoscopic ultrasound (EUS) with fine needle aspiration (FNA) to detect a mediastinal lymph node metastasis ($18,603 per patient), compared with combined EUS FNA and endobronchial ultrasound (EBUS) with FNA ($18,753). The results were sensitive to the prevalence of malignant mediastinal lymph nodes; EUS FNA remained least costly, if the probability of nodal metastases was <32.9%, as would occur in a patient without abnormal lymph nodes on computed tomography (CT). While EUS FNA combined with EBUS FNA was the most economical approach, if the rate of nodal metastases was higher, as would be the case in patients with abnormal lymph nodes on CT. Both of these strategies were less costly than bronchoscopy or mediastinoscopy. The pre-test probability of nodal metastases can determine the most cost-effective testing strategy for evaluation of a patient with NSCLC. Pre-procedure CT may be helpful in assessing probability of mediastinal nodal metastases.

  9. Paraffin-gel tissue-mimicking material for ultrasound-guided needle biopsy phantom.

    Science.gov (United States)

    Vieira, Sílvio L; Pavan, Theo Z; Junior, Jorge E; Carneiro, Antonio A O

    2013-12-01

    Paraffin-gel waxes have been investigated as new soft tissue-mimicking materials for ultrasound-guided breast biopsy training. Breast phantoms were produced with a broad range of acoustical properties. The speed of sound for the phantoms ranged from 1425.4 ± 0.6 to 1480.3 ± 1.7 m/s at room temperature. The attenuation coefficients were easily controlled between 0.32 ± 0.27 dB/cm and 2.04 ± 0.65 dB/cm at 7.5 MHz, depending on the amount of carnauba wax added to the base material. The materials do not suffer dehydration and provide adequate needle penetration, with a Young's storage modulus varying between 14.7 ± 0.2 kPa and 34.9 ± 0.3 kPa. The phantom background material possesses long-term stability and can be employed in a supine position without changes in geometry. These results indicate that paraffin-gel waxes may be promising materials for training radiologists in ultrasound biopsy procedures. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  10. MRI-Guided Focused Ultrasound as a New Method of Drug Delivery

    Directory of Open Access Journals (Sweden)

    M. Thanou

    2013-01-01

    Full Text Available Ultrasound-mediated drug delivery under the guidance of an imaging modality can improve drug disposition and achieve site-specific drug delivery. The term focal drug delivery has been introduced to describe the focal targeting of drugs in tissues with the help of imaging and focused ultrasound. Focal drug delivery aims to improve the therapeutic profile of drugs by improving their specificity and their permeation in defined areas. Focused-ultrasound- (FUS- mediated drug delivery has been applied with various molecules to improve their local distribution in tissues. FUS is applied with the aid of microbubbles to enhance the permeability of bioactive molecules across BBB and improve drug distribution in the brain. Recently, FUS has been utilised in combination with MRI-labelled liposomes that respond to temperature increase. This strategy aims to “activate” nanoparticles to release their cargo locally when triggered by hyperthermia induced by FUS. MRI-guided FUS drug delivery provides the opportunity to improve drug bioavailability locally and therefore improve the therapeutic profiles of drugs. This drug delivery strategy can be directly translated to clinic as MRg FUS is a promising clinically therapeutic approach. However, more basic research is required to understand the physiological mechanism of FUS-enhanced drug delivery.

  11. A serious game for learning ultrasound-guided needle placement skills.

    Science.gov (United States)

    Chan, Wing-Yin; Qin, Jing; Chui, Yim-Pan; Heng, Pheng-Ann

    2012-11-01

    Ultrasound-guided needle placement is a key step in a lot of radiological intervention procedures such as biopsy, local anesthesia and fluid drainage. To help training future intervention radiologists, we develop a serious game to teach the skills involved. We introduce novel techniques for realistic simulation and integrate game elements for active and effective learning. This game is designed in the context of needle placement training based on the some essential characteristics of serious games. Training scenarios are interactively generated via a block-based construction scheme. A novel example-based texture synthesis technique is proposed to simulate corresponding ultrasound images. Game levels are defined based on the difficulties of the generated scenarios. Interactive recommendation of desirable insertion paths is provided during the training as an adaptation mechanism. We also develop a fast physics-based approach to reproduce the shadowing effect of needles in ultrasound images. Game elements such as time-attack tasks, hints and performance evaluation tools are also integrated in our system. Extensive experiments are performed to validate its feasibility for training.

  12. Mediastinal abscess after endobronchial ultrasound-guided transbronchial needle aspiration: a case report and literature review.

    Science.gov (United States)

    Leong, Steven C; Marshall, Henry M; Bint, Michael; Yang, Ian A; Bowman, Rayleen V; Fong, Kwun M

    2013-10-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive technique that allows lung cancer nodal staging and biopsy of parabronchial and paratracheal tissue. Its simplicity, high diagnostic yield, ability to diagnose both benign and malignant conditions, and exceedingly low complication rate has resulted in rapid widespread adoption by surgeons and physicians. EBUS-TBNA-related complications, however, do occur and need to be considered when assessing the risk-benefit profile of performing the procedure, and if the patient represents with unexpected symptoms after the procedure. We describe a 64-year-old woman who presented with a mediastinal abscess 5 days after EBUS-TBNA. This case demonstrates the importance of considering EBUS-TBNA-related complications to guide relevant imaging decisions and antibiotic choices. We review the published literature regarding infective complications of EBUS-TBNA and propose possible pathophysiologies. These complications are likely to increase in frequency as the technique is more widely adopted.

  13. Brief reports: ultrasound-guided obturator nerve block: a proximal interfascial technique.

    Science.gov (United States)

    Taha, Ahmad Muhammad

    2012-01-01

    In this report, I describe and evaluate a proximal ultrasound (US)-guided obturator nerve block technique using an interfascial local anesthetic (LA) injection deep to the pectineus muscle. The pectineus muscle was identified and followed, while the US probe was tilted cranially until the superior pubic ramus was visualized. In this plane, LA was injected interfascially between the pectineus and obturator externus. The median time required to identify the injection site was 4 seconds (95% confidence interval, 3-5 seconds). The median motor block onset was 4 minutes (95% confidence interval, 3-5 minutes). Both obturator nerve branches were blocked successfully in all patients (100%). The US-guided obturator nerve block using interfascial LA injection inferior to the superior pubic ramus, between the pectineus and obturator externus muscles, was shown to be a simple and successful technique.

  14. Approach to treatment for obstructive jaundice of PTCD guided by combining ultrasound with X-ray scan

    International Nuclear Information System (INIS)

    Tang Huanliang; Cao Haoqian; Fei Jianguo

    2008-01-01

    Objective: To investigate the technical and clinical value of PTCD in patients with obstructive jaundice by the guiding of ultrasound combined with X-ray scan. Methods PTCD was performed in 58 patients with obstructive jaundice, with 47 patients malignant diseases and 11 patients benign diseases, guided by combining ultrasound and X-ray scan. 51 patients were punctured to right bile ducts and 7 cases were left bile ducts. Cholangiography was routinely used. Results: Technical success was obtained in all patients. No bleeding and biliary peritonitis were found after procedures. The bilirubin was reduced by 75.4ummol/L one week after operation. Conclusion: The technique of PTCD guided by combining ultrasound with X-ray scan was safe, simple, cost saving and less complications for obstructive jaundice. (authors)

  15. Ultrasound-Guided Peripheral Intravenous Access in the Emergency Department: Patient-Centered Survey

    Directory of Open Access Journals (Sweden)

    Keith Boniface

    2011-05-01

    Full Text Available Introduction: To assess characteristics, satisfaction, and disposition of emergency department (ED patients who successfully received ultrasound (US-guided peripheral intravenous (IV access. Methods: This is a prospective observational study among ED patients who successfully received US-guided peripheral IV access by ED technicians. Nineteen ED technicians were taught to use US guidance to obtain IV access. Training sessions consisted of didactic instruction and hands-on practice. The US guidance for IV access was limited to patients with difficult access. After successfully receiving an US-guided peripheral IV, patients were approached by research assistants who administered a 10-question survey. Disposition information was collected after the conclusion of the ED visit by accessing patients’ electronic medical record. Results: In total, 146 surveys were completed in patients successfully receiving US-guided IVs. Patients reported an average satisfaction with the procedure of 9.2 of 10. Forty-two percent of patients had a body mass index (BMI of greater than 30, and 17.8% had a BMI of more than 35. Sixty-two percent reported a history of central venous catheter placement. This patient population averaged 3 ED visits per year in the past year. Fifty-three percent of the patients were admitted. Conclusion: Patients requiring US-guided IVs in our ED are discharged home at the conclusion of their ED visit about half of the time. These patients reported high rates of both difficult IV access and central venous catheter placement in the past. Patient satisfaction with US-guided IVs was very high. These data support the continued use of US-guided peripheral IVs in this patient population. [West J Emerg Med. 2011;12(4:475–477.

  16. Combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures

    International Nuclear Information System (INIS)

    Sommer, C.M.; Huber, J.; Radeleff, B.A.; Hosch, W.; Stampfl, U.; Loenard, B.M.; Hallscheidt, P.; Haferkamp, A.; Kauczor, H.U.; Richter, G.M.

    2011-01-01

    Aim: To report our experience of combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures. Patients and methods: Eighteen patients (23 kidneys) with non-obstructive uropathy due to urine leaks underwent combined CT- and fluoroscopy-guided nephrostomy. All procedures were indicated as second-line interventions after failed ultrasound-guided nephrostomy. Thirteen males and five females with an age of 62.3 ± 8.7 (40–84) years were treated. Urine leaks developed in majority after open surgery, e.g. postoperative insufficiency of ureteroneocystostomy (5 kidneys). The main reasons for failed ultrasound-guided nephrostomy included anatomic obstacles in the puncture tract (7 kidneys), and inability to identify pelvic structures (7 kidneys). CT-guided guidewire placement into the collecting system was followed by fluoroscopy-guided nephrostomy tube positioning. Procedural success rate, major and minor complication rates, CT-views and needle passes, duration of the procedure and radiation dose were analyzed. Results: Procedural success was 91%. Major and minor complication rates were 9% (one septic shock and one perirenal abscess) and 9% (one perirenal haematoma and one urinoma), respectively. 30-day mortality rate was 6%. Number of CT-views and needle passes were 9.3 ± 6.1 and 3.6 ± 2.6, respectively. Duration of the complete procedure was 87 ± 32 min. Dose-length product and dose-area product were 1.8 ± 1.4 Gy cm and 3.9 ± 4.3 Gy cm 2 , respectively. Conclusions: Combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures was feasible with high technical success and a tolerable complication rate.

  17. Intraoperative Neurophysiological Monitoring for Endoscopic Endonasal Approaches to the Skull Base: A Technical Guide

    Directory of Open Access Journals (Sweden)

    Harminder Singh

    2016-01-01

    Full Text Available Intraoperative neurophysiological monitoring during endoscopic, endonasal approaches to the skull base is both feasible and safe. Numerous reports have recently emerged from the literature evaluating the efficacy of different neuromonitoring tests during endonasal procedures, making them relatively well-studied. The authors report on a comprehensive, multimodality approach to monitoring the functional integrity of at risk nervous system structures, including the cerebral cortex, brainstem, cranial nerves, corticospinal tract, corticobulbar tract, and the thalamocortical somatosensory system during endonasal surgery of the skull base. The modalities employed include electroencephalography, somatosensory evoked potentials, free-running and electrically triggered electromyography, transcranial electric motor evoked potentials, and auditory evoked potentials. Methodological considerations as well as benefits and limitations are discussed. The authors argue that, while individual modalities have their limitations, multimodality neuromonitoring provides a real-time, comprehensive assessment of nervous system function and allows for safer, more aggressive management of skull base tumors via the endonasal route.

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ... bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the prostate gland because ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Because ultrasound provides real-time images, it also can be used to guide procedures such as needle ...

  1. Temporal regularization of ultrasound-based liver motion estimation for image-guided radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    O’Shea, Tuathan P., E-mail: tuathan.oshea@icr.ac.uk; Bamber, Jeffrey C.; Harris, Emma J. [Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden NHS foundation Trust, Sutton, London SM2 5PT (United Kingdom)

    2016-01-15

    Purpose: Ultrasound-based motion estimation is an expanding subfield of image-guided radiation therapy. Although ultrasound can detect tissue motion that is a fraction of a millimeter, its accuracy is variable. For controlling linear accelerator tracking and gating, ultrasound motion estimates must remain highly accurate throughout the imaging sequence. This study presents a temporal regularization method for correlation-based template matching which aims to improve the accuracy of motion estimates. Methods: Liver ultrasound sequences (15–23 Hz imaging rate, 2.5–5.5 min length) from ten healthy volunteers under free breathing were used. Anatomical features (blood vessels) in each sequence were manually annotated for comparison with normalized cross-correlation based template matching. Five sequences from a Siemens Acuson™ scanner were used for algorithm development (training set). Results from incremental tracking (IT) were compared with a temporal regularization method, which included a highly specific similarity metric and state observer, known as the α–β filter/similarity threshold (ABST). A further five sequences from an Elekta Clarity™ system were used for validation, without alteration of the tracking algorithm (validation set). Results: Overall, the ABST method produced marked improvements in vessel tracking accuracy. For the training set, the mean and 95th percentile (95%) errors (defined as the difference from manual annotations) were 1.6 and 1.4 mm, respectively (compared to 6.2 and 9.1 mm, respectively, for IT). For each sequence, the use of the state observer leads to improvement in the 95% error. For the validation set, the mean and 95% errors for the ABST method were 0.8 and 1.5 mm, respectively. Conclusions: Ultrasound-based motion estimation has potential to monitor liver translation over long time periods with high accuracy. Nonrigid motion (strain) and the quality of the ultrasound data are likely to have an impact on tracking

  2. A review of the benefits and pitfalls of phantoms in ultrasound-guided regional anesthesia.

    Science.gov (United States)

    Hocking, Graham; Hebard, Simon; Mitchell, Christopher H

    2011-01-01

    With the growth of ultrasound-guided regional anesthesia, so has the requirement for training tools to practice needle guidance skills and evaluate echogenic needles. Ethically, skills in ultrasound-guided needle placement should be gained in a phantom before performance of nerve blocks on patients in clinical practice. However, phantom technology is varied, and critical evaluation of the images is needed to understand their application to clinical use. Needle visibility depends on the echogenicity of the needle relative to the echogenicity of the tissue adjacent the needle. We demonstrate this point using images of echogenic and nonechogenic needles in 5 different phantoms at both shallow angles (20 degrees) and steep angles (45 degrees). The echogenicity of phantoms varies enormously, and this impacts on how needles are visualized. Water is anechoic, making all needles highly visible, but does not fix the needle to allow practice placement. Gelatin phantoms and Blue Phantoms provide tactile feedback but have very low background echogenicity, which greatly exaggerates needle visibility. This makes skill acquisition easier but can lead to false confidence in regard to clinical ability. Fresh-frozen cadavers retain much of the textural feel of live human tissue and are nearly as echogenic. Similar to clinical practice, this makes needles inserted at steep angles practically invisible, unless they are highly echogenic. This review describes the uses and pitfalls of phantoms that have been described or commercially produced. Copyright © 2011 by American Society of Regional Anesthesia and Pain Medicine

  3. Ultrasound-guided paravertebral block for pyloromyotomy in 3 neonates with congenital hypertrophic pyloric stenosis

    Directory of Open Access Journals (Sweden)

    Javier Mata-Gómez

    2015-08-01

    Full Text Available BACKGROUND AND OBJECTIVES: Hypertrophic pyloric stenosis is a relatively common affection of gastrointestinal tract in childhood that results in symptoms, such as projectile vomiting and metabolic disorders that imply a high risk of aspiration during anesthetic induction. In this way, the carrying out of a technique with general anesthesia and intravenous rapid sequence induction, preoxygenation and cricoid pressure are recommended. After the correction of systemic metabolic alkalosis and pH normalization, cerebrospinal fluid can keep a state of metabolic alkalosis. This circumstance, in addition to the residual effect of neuromuscular blocking agents, inhalant anesthetics and opioids could increase the risk of postoperative apnea after a general anesthesia.CASE REPORT: We present the successful management in 3 neonates in those a pyloromyotomy was carried out because they had presented congenital hypertrophic pyloric stenosis. This procedure was done under general anesthesia with orotracheal intubation and rapid sequence induction. Then, ultrasound-guided paravertebral block was performed as analgesic method without the need for administrating opioids within intraoperative period and keeping an appropriate analgesic level.CONCLUSIONS: Local anesthesia has demonstrated to be safe and effective in pediatric practice. We consider the ultrasound-guided paravertebral block with one dose as a possible alternative for other local techniques described, avoiding the use of opioids and neuromuscular blocking agents during general anesthesia, and reducing the risk of central apnea within postoperative period.

  4. Training and certification in endobronchial ultrasound-guided transbronchial needle aspiration

    Science.gov (United States)

    Konge, Lars; Nayahangan, Leizl Joy; Clementsen, Paul Frost

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) plays a key role in the staging of lung cancer, which is crucial for allocation to surgical treatment. EBUS-TBNA is a complicated procedure and simulation-based training is helpful in the first part of the long learning curve prior to performing the procedure on actual patients. New trainees should follow a structured training programme consisting of training on simulators to proficiency as assessed with a validated test followed by supervised practice on patients. The simulation-based training is superior to the traditional apprenticeship model and is recommended in the newest guidelines. EBUS-TBNA and oesophageal ultrasound-guided fine needle aspiration (EUS-FNA or EUS-B-FNA) are complementary to each other and the combined techniques are superior to either technique alone. It is logical to learn and to perform the two techniques in combination, however, for lung cancer staging solely EBUS-TBNA simulators exist, but hopefully in the future simulation-based training in EUS will be possible. PMID:28840013

  5. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    International Nuclear Information System (INIS)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun

    1993-01-01

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer

  6. Percutaneous Ultrasound-Guided Carpal Tunnel Release: Study Upon Clinical Efficacy and Safety

    Energy Technology Data Exchange (ETDEWEB)

    Petrover, David, E-mail: dpetrover@yahoo.fr; Silvera, Jonathan, E-mail: silvera.jonathan@gmail.com [Imagerie Médicale Paris Centre Bachaumont-clinique Blomet RamsayGDS, Department of Interventional Radiology (France); Baere, Thierry De, E-mail: Debaere@igr.fr [Gustave Roussy Institute (France); Vigan, Marie, E-mail: marie.vigan@gmail.com [Association pour la recherche en chirurgie de l’épaule et du coude, clinique Drouot (France); Hakimé, Antoine, E-mail: thakime@yahoo.com [Imagerie Médicale Paris Centre Bachaumont-clinique Blomet RamsayGDS, Department of Interventional Radiology (France)

    2017-04-15

    ObjectivesTo evaluate the feasibility and 6 months clinical result of sectioning of the transverse carpal ligament (TCL) and median nerve decompression after ultra-minimally invasive, ultrasound-guided percutaneous carpal tunnel release (PCTR) surgery.MethodsConsecutive patients with carpal tunnel syndrome were enrolled in this descriptive, open-label study. The procedure was performed in the interventional radiology room. Magnetic resonance imaging was performed at baseline and 1 month. The Boston Carpal Tunnel Questionnaire was administered at baseline, 1, and 6 months.Results129 patients were enrolled. Significant decreases in mean symptom severity scores (3.3 ± 0.7 at baseline, 1.7 ± 0.4 at Month 1, 1.3 ± 0.3 at Month 6) and mean functional status scores (2.6 ± 1.1 at baseline, 1.6 ± 0.4 at Month 1, 1.3 ± 0.5 at Month 6) were noted. Magnetic resonance imaging showed a complete section of all TCL and nerve decompression in 100% of patients. No complications were identified.ConclusionsUltrasound-guided PCTR was used successfully to section the TCL, decompress the median nerve, and reduce self-reported symptoms.

  7. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun [Seoul Red Cross Hospital, Seoul (Korea, Republic of)

    1993-05-15

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer.

  8. Calcific tendinopathy of the shoulder with intraosseous extension: outcomes of ultrasound-guided percutaneous irrigation

    Energy Technology Data Exchange (ETDEWEB)

    Klontzas, Michail E. [University Hospital and Department of Radiology, University of Crete, Department of Medical Imaging, Heraklion, Crete (Greece); Imperial College London, Department of Chemical Engineering, London (United Kingdom); Vassalou, Evangelia E.; Karantanas, Apostolos H. [University Hospital and Department of Radiology, University of Crete, Department of Medical Imaging, Heraklion, Crete (Greece)

    2017-02-15

    Rotator cuff calcific tendinopathy (RCCT) with intraosseous extension is a rare complication of tendinous and peritendinous involvement. The purpose of our study is to evaluate the outcome of ultrasound-guided percutaneous irrigation of calcific tendinopathy (US-PICT) in patients with intraosseous involvement. From January 2011 to June 2014, patients with a clinical and imaging diagnosis of RCCT were prospectively categorised in two groups based on imaging findings: group A (10 patients) with intraosseous RCCT and group B (control group 35 patients) without osseous involvement. US-PICT followed by subacromial injection was applied to all patients in groups A and B. During a 1-year follow-up, treatment outcome in terms of pain and functional improvement was evaluated at 3 weeks, 3 months, 6 months, and 1 year, with the use of a four-grade scale. The study has been approved by our hospital's ethics committee. Mean improvement scores of group A were significantly lower than those of group B at all time points (p < 0.0001). Improvement of group B was noted mainly within the first 3 months post-treatment (p = 0.016). Outcomes of ultrasound-guided treatment in cases of RCCT with intraosseous extension are significantly less favourable than in purely tendinous or peritendinous disease. (orig.)

  9. Calcific tendinopathy of the shoulder with intraosseous extension: outcomes of ultrasound-guided percutaneous irrigation

    International Nuclear Information System (INIS)

    Klontzas, Michail E.; Vassalou, Evangelia E.; Karantanas, Apostolos H.

    2017-01-01

    Rotator cuff calcific tendinopathy (RCCT) with intraosseous extension is a rare complication of tendinous and peritendinous involvement. The purpose of our study is to evaluate the outcome of ultrasound-guided percutaneous irrigation of calcific tendinopathy (US-PICT) in patients with intraosseous involvement. From January 2011 to June 2014, patients with a clinical and imaging diagnosis of RCCT were prospectively categorised in two groups based on imaging findings: group A (10 patients) with intraosseous RCCT and group B (control group 35 patients) without osseous involvement. US-PICT followed by subacromial injection was applied to all patients in groups A and B. During a 1-year follow-up, treatment outcome in terms of pain and functional improvement was evaluated at 3 weeks, 3 months, 6 months, and 1 year, with the use of a four-grade scale. The study has been approved by our hospital's ethics committee. Mean improvement scores of group A were significantly lower than those of group B at all time points (p < 0.0001). Improvement of group B was noted mainly within the first 3 months post-treatment (p = 0.016). Outcomes of ultrasound-guided treatment in cases of RCCT with intraosseous extension are significantly less favourable than in purely tendinous or peritendinous disease. (orig.)

  10. Power cavitation-guided blood-brain barrier opening with focused ultrasound and microbubbles

    Science.gov (United States)

    Burgess, M. T.; Apostolakis, I.; Konofagou, E. E.

    2018-03-01

    Image-guided monitoring of microbubble-based focused ultrasound (FUS) therapies relies on the accurate localization of FUS-stimulated microbubble activity (i.e. acoustic cavitation). Passive cavitation imaging with ultrasound arrays can achieve this, but with insufficient spatial resolution. In this study, we address this limitation and perform high-resolution monitoring of acoustic cavitation-mediated blood-brain barrier (BBB) opening with a new technique called power cavitation imaging. By synchronizing the FUS transmit and passive receive acquisition, high-resolution passive cavitation imaging was achieved by using delay and sum beamforming with absolute time delays. Since the axial image resolution is now dependent on the duration of the received acoustic cavitation emission, short pulses of FUS were used to limit its duration. Image sets were acquired at high-frame rates for calculation of power cavitation images analogous to power Doppler imaging. Power cavitation imaging displays the mean intensity of acoustic cavitation over time and was correlated with areas of acoustic cavitation-induced BBB opening. Power cavitation-guided BBB opening with FUS could constitute a standalone system that may not require MRI guidance during the procedure. The same technique can be used for other acoustic cavitation-based FUS therapies, for both safety and guidance.

  11. Ultrasound-guided hydrostatic reduction of intussusception with saline: Safe and effective.

    Science.gov (United States)

    Karadağ, Çetin Ali; Abbasoğlu, Latif; Sever, Nihat; Kalyoncu, Meltem Kaba; Yıldız, Abdullah; Akın, Melih; Candan, Mustafa; Dokucu, Ali İhsan

    2015-09-01

    The study was undertaken to assess the efficacy of ultrasound-guided saline enema in reducing intussusception and to determine the role of age and duration of symptoms on this event. The case records of patients who were treated for intussusception at our institutions over the past 10 years were retrospectively analyzed. A total of 419 patients were treated for intussusception and 375 of them were included into the study. Patients were excluded if they had symptoms and signs of acute abdominal disease and required surgery as an initial treatment. Hydrostatic reduction was successful in 313 of the 375 patients (83.46%). The procedure-related complication rate was nil. There were 29 episodes of recurrences in 23 patients, and recurrence rates did not differ between patients who responded to hydrostatic reduction and those who required surgery. Younger age [median (range); 11 months (3-108 months) vs. 20 months (1-180 months); phydrostatic reduction. Ultrasound-guided hydrostatic reduction is an easy, safe and effective method for the treatment of intussusception in the absence of acute abdominal findings. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Percutaneous Ultrasound-Guided Carpal Tunnel Release: Study Upon Clinical Efficacy and Safety

    International Nuclear Information System (INIS)

    Petrover, David; Silvera, Jonathan; Baere, Thierry De; Vigan, Marie; Hakimé, Antoine

    2017-01-01

    ObjectivesTo evaluate the feasibility and 6 months clinical result of sectioning of the transverse carpal ligament (TCL) and median nerve decompression after ultra-minimally invasive, ultrasound-guided percutaneous carpal tunnel release (PCTR) surgery.MethodsConsecutive patients with carpal tunnel syndrome were enrolled in this descriptive, open-label study. The procedure was performed in the interventional radiology room. Magnetic resonance imaging was performed at baseline and 1 month. The Boston Carpal Tunnel Questionnaire was administered at baseline, 1, and 6 months.Results129 patients were enrolled. Significant decreases in mean symptom severity scores (3.3 ± 0.7 at baseline, 1.7 ± 0.4 at Month 1, 1.3 ± 0.3 at Month 6) and mean functional status scores (2.6 ± 1.1 at baseline, 1.6 ± 0.4 at Month 1, 1.3 ± 0.5 at Month 6) were noted. Magnetic resonance imaging showed a complete section of all TCL and nerve decompression in 100% of patients. No complications were identified.ConclusionsUltrasound-guided PCTR was used successfully to section the TCL, decompress the median nerve, and reduce self-reported symptoms.

  13. Distribution of Platelet-rich Plasma after Ultrasound-Guided Injection for Chronic Elbow Tendinopathies

    Directory of Open Access Journals (Sweden)

    Gi-Young Park, Dong Rak Kwon, Hee Kyung Cho, Jinyoung Park, Jung Hyun Park

    2017-03-01

    Full Text Available Characteristics of the spreads of platelet-rich plasma (PRP are not widely known despite commonly use. This study aims to evaluate whether PRP stays within the injected area by using ultrasonography, to improve understanding of the spreads of intratendinous injected PRP. Thirty-nine patients (15 males, 24 females; mean age, 49.3 years, who had symptoms on their elbows (> 6 months and diagnosed as lateral (25 elbows or medial (14 elbows tendinopathies of elbow, were included. The severity of tendon pathology was assessed by ultrasonography as tear or no tear. Immediately after ultrasound-guided PRP injection, ultrasound images were evaluated to assess the area of PRP distribution, which was defined as the presence of fluid or microbubbles. Ultrasound revealed that 13 elbows had tendon tear and 26 had no tear, respectively. Post-injection ultrasound confirmed the injected PRP was within the tendon in all cases. The mean distance of distribution from the injection site was 12.6 mm (5.0–26.0 mm. There was no difference in the distance of PRP distribution between tendon tear and no tear. Injected PRP spread to soft tissue outside the tendon in 20 of 39 cases. Intra-articular extension of PRP was observed in 5 cases. Although PRP remained intratendinous after the injection in all cases, some portion tended to spread outside from the injection site in a short space of time. Postinjection ultrasonographic imaging has a value for observing the spreading patterns of intratendinous PRP injection.

  14. Comparison of Ultrasound-Guided Thrombin Injection of Iatrogenic Pseudoaneurysms Based on Neck Dimension.

    Science.gov (United States)

    Yang, Ethan Y; Tabbara, Marwan M; Sanchez, Priscila G; Abi-Chaker, Andrew M; Patel, Jaimin; Bornak, Arash; Jones, Keith M; Rey, Jorge

    2018-02-01

    Ultrasound-guided thrombin injection (UGTI) of femoral artery pseudoaneurysms after endovascular procedures is an effective therapy. There is controversy in the literature regarding injecting pseudoaneurysms with short and/or wide necks. This article reports our experience in UGTI of pseudoaneurysms in 1 hospital regarding the efficacy of this treatment in all pseudoaneurysms regardless of the size of the necks. A retrospective review of 46 patients diagnosed between 2011 and 2016 with groin pseudoaneurysms using established duplex ultrasound criteria. Mean age was 68 years (range 27-87). Ten pseudoaneurysms thrombosed spontaneously, 5 were thrombosed by ultrasound-guided compression, and 2 were treated surgically due to disqualifying criteria. In this retrospective review, we analyzed the remaining 29 pseudoaneurysms regarding the dimensions of their neck lengths and outcomes after attempting thrombin injection. The mean aneurysm neck length and width were 1.03 ± 0.9 cm and 0.30 ± 0.1 cm, respectively. All 29 patients were evaluated with respect to pseudoaneurysm size, neck length, neck width, and complexity. Successful treatment of 29 pseudoaneurysms (2 external iliac, 20 common femoral, 2 deep femoral, and 5 superficial femoral) with UGTI was achieved without complications in 100% of the cases, regardless of pseudoaneurysm size, neck dimensions, or complexity. Anticoagulation status did not affect the efficacy of the procedure. Nine of the 29 pseudoaneurysms (31.0%) had neck length less than 0.5 cm. This study demonstrates the safety and efficacy of UGTI in treating iatrogenic pseudoaneurysm in 29 of 29 patients, even in patients with pseudoaneurysm with short neck lengths. Our experiences support injecting all pseudoaneurysms irrespective of dimension. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Ultrasound-guided plantar fascia release technique: a retrospective study of 46 feet.

    Science.gov (United States)

    Vohra, Praveen K; Japour, Christopher J

    2009-01-01

    Ultrasound-guided plantar fascia release offers the surgeon clear visualization of anatomy at the surgical site. This technique uses small arthroscopic dissecting instruments through a 0.5-cm incision, allowing the surgeon to avoid the larger and more tissue-disruptive incision that is traditionally used for plantar heel spur resection and plantar fascia releases. Forty-one patients (46 feet) were selected for the study. The mean patient age was 47 years. Twenty-nine were considered obese with a body mass index greater than 30 kg/m(2). Patients were functionally and subjectively evaluated 4 weeks after surgery using the American Orthopedic Foot and Ankle Society Ankle and Hindfoot Rating Scale. Results from the study show a significant improvement (P = .05 confidence level) 4 weeks postoperatively for the 41 patients (46 feet), compared to their preoperative condition. The mean pretest score was 33.6 (range 10-52); this score improved to 88.0 (range 50-100), 4 weeks postoperatively. There were no postoperative infections or complications. The ultrasound-guided plantar fascia release technique is a practical surgical procedure for the relief of chronic plantar fascia pain because the surgeon is able to clearly visualize the plantar fascia by ultrasound. In addition, there is minimal disruption to surrounding tissue because small instruments are passed through a small 0.5-cm incision. The traditional open method of heel spur surgery, in contrast, uses a larger skin incision of 3 to 5 cm, followed by larger instruments to dissect to the plantar fascia.

  16. An inexpensive, easily constructed, reusable task trainer for simulating ultrasound-guided pericardiocentesis.

    Science.gov (United States)

    Zerth, Herb; Harwood, Robert; Tommaso, Laura; Girzadas, Daniel V

    2012-12-01

    Pericardiocentesis is a low-frequency, high-risk procedure integral to the practice of emergency medicine. Ultrasound-guided pericardiocentesis is the preferred technique for providing this critical intervention. Traditionally, emergency physicians learned pericardiocentesis in real time, at the bedside, on critically ill patients. Medical education is moving toward simulation for training and assessment of procedures such as pericardiocentesis because it allows learners to practice time-sensitive skills without risk to patient or learner. The retail market for models for pericardiocentesis practice is limited and expensive. We have developed an ultrasound-guided pericardiocentesis task trainer that allows the physician to insert a needle under ultrasound guidance, pierce the "pericardial sac" and aspirate "blood." Our model can be simply constructed in a home kitchen, and the overall preparation time is 1 h. Our model costs $20.00 (US, 2008). Materials needed for the construction include 16 ounces of plain gelatin, one large balloon, one golf ball, food coloring, non-stick cooking spray, one wooden cooking skewer, surgical iodine solution, and a 4-quart sized plastic food storage container. Refrigeration and a heat source for cooking are also required. Once prepared, the model is usable for 2 weeks at room temperature and may be preserved an additional week if refrigerated. When the model shows signs of wear, it can be easily remade, by simply recycling the existing materials. The self-made model was well liked by training staff due to accessibility of a simulation model, and by learners of the technique as they felt more at ease performing pericardiocentesis on a live patient. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. Ultrasound-guided approach to the paravertebral space for catheter insertion in infants and children.

    Science.gov (United States)

    Boretsky, Karen; Visoiu, Mihaela; Bigeleisen, Paul

    2013-12-01

    Paravertebral perineural blocks are used to prevent pain in the thoracoabdominal dermatomes. Traditionally, a landmark-based technique is used in children, while ultrasound-guided (UG) techniques are being employed in adult patients. To describe an UG technique for placement of thoracic paravertebral nerve block (TPVNB) catheters in pediatric patients. Retrospective chart review of a series of 22 pediatric patients' ages 6 months to 17 years with weights from 6.25 kg to 135 kg using a transverse in-plane technique. Catheters were placed both bilateral and unilateral for a variety of thoracic and abdominal procedures. A linear ultrasound transducer was used in all cases with frequency of oscillation and transducer length chosen based on individual patient characteristics of age, weight, and BMI. The median pain scores at 12, 24, 36, and 48 h were 1.2 (interquartile range, 4.5), 0.84 (interquartile range 3.0), 1.6 (interquartile range 2.9), and 0.83 (interquartile range 1.74), respectively. The median dose of opioid expressed as morphine equivalents consumed during the first 24 h after surgery was 0.14 mg·kg(-1) (interquartile range, 0.78 mg·kg(-1) ) and from 24 to 48 h the median dose was 0.11 mg·kg(-1) (interquartile range 0.44 mg·kg(-1) ). No complications were noted, and catheters were left an average of 3 days with a range of 1-5 days with good pain relief. This technical description demonstrates the feasibility of placing PVNB catheters using a transverse in-line ultrasound-guided technique in a wide range of pediatric patients. © 2013 John Wiley & Sons Ltd.

  18. Ultrasound-Guided Percutaneous Dilational Tracheostomy: A Systematic Review of Randomized Controlled Trials and Meta-Analysis.

    Science.gov (United States)

    Gobatto, André L N; Besen, Bruno A M P; Cestari, Mino; Pelosi, Paolo; Malbouisson, Luiz M S

    2018-01-01

    Percutaneous dilational tracheostomy (PDT) is a common and increasingly used procedure in the intensive care unit (ICU). It is usually performed with bronchoscopy guidance. Ultrasound has emerged as a useful tool in order to assist PDT, potentially improving its success rate and reducing procedural-related complications. To investigate whether the ultrasound-guided PDT is equivalent or superior to the bronchoscopy-guided or anatomical landmarks-guided PDT with regard to procedural-related and clinical complications. A systematic review of randomized clinical trials was conducted comparing an ultrasound-guided PDT to the control groups (either a bronchoscopy-guided PDT or an anatomical landmark-guided PDT) in patients undergoing a PDT in the ICU. The primary outcome was the incidence of major procedural-related and clinical complication rates. The secondary outcome was the incidence of minor complication rates. Random-effect meta-analyzes were used to pool the results. Four studies fulfilled the inclusion criteria and they were analyzed. The studies included 588 participants. There were no differences in the major complication rates between the patients who were assigned to the ultrasound-guided PDT when compared to the control groups (pooled risk ratio [RR]: 0.48; 95% confidence interval [CI]: 0.13-1.71, I 2 = 0%). The minor complication rates were not different between the groups, but they had a high heterogeneity (pooled RR: 0.49; 95% CI 0.16-1.50; I 2 = 85%). The sensitivity analyzes that only included the randomized controlled trials that used a landmark-guided PDT as the control group showed lower rates of minor complications in the ultrasound-guided PDT group (pooled RR: 0.55; 95% CI: 0.31-0.98, I 2 = 0%). The ultrasound-guided PDT seems to be safe and it is comparable to the bronchoscopy-guided PDT regarding the major and minor procedural-related or clinical complications. It also seems to reduce the minor complications when compared to the anatomical

  19. Ultrasound-guided transversus abdominis plane (TAP) block: a useful adjunct in the management of postoperative respiratory failure.

    Science.gov (United States)

    Singh, Mandeep; Chin, Ki Jinn; Chan, Vincent

    2011-06-01

    The ultrasound-guided transversus abdominis plane (TAP) block is a useful tool in controlling postoperative pain following abdominal surgery. The bilateral ultrasound-guided TAP blocks successfully managed the pain of a patient presenting with hypoxemia and respiratory failure in the Post-anesthesia Care Unit, following a laparotomy for small bowel obstruction during general anesthesia. The TAP block reduced systemic opioid requirements and opioid-induced sedation and respiratory depression, improved patient compliance with non-invasive positive pressure ventilation, and prevented the need for intubation and ventilation in the intensive care unit. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Intra-articular distribution pattern after ultrasound-guided injections in wrist joints of patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Boesen, Mikael; Jensen, Karl Erik; Torp-Pedersen, Søren

    2007-01-01

    OBJECTIVE: To investigate the distribution of an ultrasound-guided intra-articular (IA) injection in the wrist joint of patients with rheumatoid arthritis (RA). METHODS: An ultrasound-guided IA drug injection into the wrist joint was performed in 17 patients with 1 ml methylprednisolone (40 mg...... with the MRI OMERACT synovitis score (r=0.60, p=0.014), but not with the erosions, bonemarrow oedema scores or any clinical parameters. CONCLUSION: The distribution of contrast on MRI showed patient specific and random patterns after IA injections in active RA wrist joints. The degree of distribution increased...

  1. Delphi Method Validation of a Procedural Performance Checklist for Insertion of an Ultrasound-Guided Internal Jugular Central Line.

    Science.gov (United States)

    Hartman, Nicholas; Wittler, Mary; Askew, Kim; Manthey, David

    2016-01-01

    Placement of ultrasound-guided central lines is a critical skill for physicians in several specialties. Improving the quality of care delivered surrounding this procedure demands rigorous measurement of competency, and validated tools to assess performance are essential. Using the iterative, modified Delphi technique and experts in multiple disciplines across the United States, the study team created a 30-item checklist designed to assess competency in the placement of ultrasound-guided internal jugular central lines. Cronbach α was .94, indicating an excellent degree of internal consistency. Further validation of this checklist will require its implementation in simulated and clinical environments. © The Author(s) 2014.

  2. Medial approach of ultrasound-guided costoclavicular plexus block and its effects on regional perfussion.

    Science.gov (United States)

    Nieuwveld, D; Mojica, V; Herrera, A E; Pomés, J; Prats, A; Sala-Blanch, X

    2017-04-01

    Ultrasound-guided infraclavicular block in the costoclavicular space located between the clavicle and the first rib, reaches the secondary trunks when they are clustered together and lateral to the axillary artery. This block is most often performed through a lateral approach, the difficulty being finding the coracoid process an obstacle and guiding the needle towards the vessels and pleura. A medial approach, meaning from inside to outside, will avoid these structures. Traditionally the assessment of a successful block is through motor or sensitive responses but a sympathetic fibre block can also be evaluated measuring the changes in humeral artery blood flow, skin temperature and/or perfusion index. To describe the medial approach of the ultrasound-guided costoclavicular block evaluating its development by motor and sensitive response and measurement of sympathetic changes. Description of the technique and administration of 20ml of contrast in a fresh cadaver model, evaluating the distribution with CT-scan and sagittal sections of the anatomic piece. Subsequently in a clinical phase, including 11 patients, we evaluated the establishment of motor, sensitive and sympathetic blocks. We evaluated the sympathetic changes reflected by humeral artery blood flow, skin temperature and distal perfusion index. In the anatomical model the block was conducted without difficulties, showing an adequate periclavicular distribution of the contrast in the CT-scan and in sagittal sections, reaching the interscalenic space as far as the secondary trunks. Successful blocks were observed in 91% of patients after 25minutes. All the parameters reflecting sympathetic block increased significantly. The humeral artery blood flow showed an increase from 108 ± 86 to 188±141ml/min (P=.05), skin temperature from 32.1±2 to 32.8±9°C (P=.03) and perfusion index from 4±3 to 9±5 (P=.003). The medial approach of the ultrasound-guided costoclavicular block is anatomically feasible, with high

  3. Villous adenoma of the common hepatic duct: the importance of contrast-enhanced ultrasound and endoscopic retrograde cholangiopancreatography for relevant diagnosis. A case report and review of the literature.

    Science.gov (United States)

    Tefas, Cristian; Tanţău, Marcel; Szenftleben, Alexandru; Chiorean, Liliana; Badea, Radu

    2015-12-01

    Adenomas are frequently encountered in the lower digestive tract but are rarely diagnosed in the biliary tree. We report a case of villous adenoma of the common hepatic duct. A 58-year old male was admitted with a four week history of intermittent upper right quadrant pain. Gray scale and contrast-enhanced abdominal ultrasound showed a mass inside the common hepatic duct with arterial enhancement and slow wash-out during the late venous phase. Subsequent endoscopic retrograde cholangiopancreatography and intraductal ultrasound confirmed the presence of the lesion. The final histopathological examination showed villous adenoma of the common hepatic duct with high-grade dysplasia. Contrast enhanced ultrasonography used in conjecture with endoscopic retrograde cholangiopancreatography can help in differentiating biliary tumors.

  4. Endoscopic Decompression and Marsupialization of A Duodenal Duplication Cyst

    Directory of Open Access Journals (Sweden)

    Eliza I-Lin Sin

    2018-06-01

    Full Text Available Introduction: Duodenal duplication cysts are rare congenital foregut anomalies, accounting for 2%–12% of all gastrointestinal tract duplications. Surgical excision entails risk of injury to the pancreaticobiliary structures due to proximity or communication with the cyst. We present a case of duodenal duplication cyst in a 3 year-old boy who successfully underwent endoscopic decompression. Case report: AT is a young boy who first presented at 15 months of age with abdominal pain. There was one subsequent episode of pancreatitis. Ultrasonography showed the typical double wall sign of a duplication cyst and magnetic resonance cholangio-pancreatography showed a large 5 cm cyst postero-medial to the second part of the duodenum, communicating with the pancreaticobiliary system and causing dilatation of the proximal duodenum. He subsequently underwent successful endoscopic ultrasound guided decompression at 3 years of age under general anesthesia, and had an uneventful postoperative recovery. Conclusion: Endoscopic ultrasound guided assessment and treatment of gastrointestinal duplication cysts is increasingly reported in adults. To the best of our knowledge, only one case of endoscopic treatment of duodenal duplication cyst, in an older child, has been reported thus far in the paediatric literature. In this paper, we review the current literature and discuss the therapeutic options of this rare condition.

  5. Realtime ultrasound guided percutaneous tracheostomy in emergency setting: the glass ceiling has been broken.

    Science.gov (United States)

    Ravi, Parli Raghavan; Vijai, M N; Shouche, Sachin

    2017-01-01

    In recent years ultrasound guided percutaneous tracheostomy (USPCT) has become a routine practice in critical care units. Its safety and superiority over conventional percutaneous tracheostomy and bronchoscopic guided PCT is proven to be non-inferior in elective cases. However its role in emergency percutaneous tracheostomy has never been studied, since percutaneous tracheostomy itself remains an enigma in accessing emergency airway. There is no report of use of ultrasound guided percutaneous tracheostomy in emergency setting so far in the literature. We report our early experience with USPCT in emergency setting. Sixteen adult patients who required access to an emergency surgical airway after failure to accomplish emergency oro-tracheal intubation were the study population. Their airway was accessed by USPCT. Recorded data included clinical and demographic data including time taken to perform the procedure and complications. Short term and long term follow ups for a period of 2 years were done for the survivors. Twelve male and four female patients underwent the procedure and the average time of the procedure was 3.6 min with no failures nor conversions to surgical tracheostomy and no complications. The average oxygen saturation was 86% and average Glasgow coma scale was 8.4. This time period included the oxygen insufflation time. 10 patients were decannulated while six patients died due to the pathology of the disease itself. There were no complications in either short term or long term follow up. USPCT has a definitive role in emergency both in trauma and non-trauma setting. It is safe, feasible and faster in experienced hands. Use of USPCT in emergency setting has further narrowed the list of contraindications of percutaneous tracheostomy.

  6. Combined ultrasound and fluoroscopy guided port catheter implantation-High success and low complication rate

    International Nuclear Information System (INIS)

    Gebauer, Bernhard; El-Sheik, Michael; Vogt, Michael; Wagner, Hans-Joachim

    2009-01-01

    Purpose: To evaluate peri-procedural, early and late complications as well as patients' acceptance of combined ultrasound and fluoroscopy guided radiological port catheter implantation. Materials and methods: In a retrospective analysis, all consecutive radiological port catheter implantations (n = 299) between August 2002 and December 2004 were analyzed. All implantations were performed in an angio suite under analgosedation and antibiotic prophylaxis. Port insertion was guided by ultrasonographic puncture of the jugular (n = 298) or subclavian (n = 1) vein and fluoroscopic guidance of catheter placement. All data of the port implantation had been prospectively entered into a database for interventional radiological procedures. To assess long-term results, patients, relatives or primary physicians were interviewed by telephone; additional data were generated from the hospital information system. Patients and/or the relatives were asked about their satisfaction with the port implantion procedure and long-term results. Results: The technical success rate was 99% (298/299). There were no major complications according to the grading system of SIR. A total of 23 (0.33 per 1000 catheter days) complications (early (n = 4), late (n = 19)) were recorded in the follow-period of a total of 72,727 indwelling catheter days. Infectious complications accounted for 0.15, thrombotic for 0.07 and migration for 0.04 complications per 1000 catheter days. Most complications were successfully treated by interventional measures. Twelve port catheters had to be explanted due to complications, mainly because of infection (n = 9). Patients' and relatives' satisfaction with the port catheter system was very high, even if complications occurred. Conclusion: Combined ultrasound and fluoroscopy guided port catheter implantation is a very safe and reliable procedure with low peri-procedural, early and late complication rate. The intervention achieves very high acceptance by the patients and

  7. Effects of arthroscopy-guided suprascapular nerve block combined with ultrasound-guided interscalene brachial plexus block for arthroscopic rotator cuff repair: a randomized controlled trial.

    Science.gov (United States)

    Lee, Jae Jun; Hwang, Jung-Taek; Kim, Do-Young; Lee, Sang-Soo; Hwang, Sung Mi; Lee, Na Rea; Kwak, Byung-Chan

    2017-07-01

    The aim of this study was to compare the pain relieving effect of ultrasound-guided interscalene brachial plexus block (ISB) combined with arthroscopy-guided suprascapular nerve block (SSNB) with that of ultrasound-guided ISB alone within the first 48 h after arthroscopic rotator cuff repair. Forty-eight patients with rotator cuff tears who had undergone arthroscopic rotator cuff repair were enrolled. The 24 patients in group 1 received ultrasound-guided ISB and arthroscopy-guided SSNB; the remaining 24 patients in group 2 underwent ultrasound-guided ISB alone. Visual analogue scale pain score and patient satisfaction score were checked at 1, 3, 6, 12, 18, 24, and 48 h post-operatively. Group 1 had a lower visual analogue scale pain score at 3, 6, 12, 18, 24, and 48 h post-operatively (1.7  6.0, 6.2 > 4.3, 6.4 > 5.1, 6.9 > 5.9, 7.9 > 7.1). Six patients in group 1 developed rebound pain twice, and the others in group 1 developed it once. All of the patients in group 2 had one rebound phenomenon each (p = 0.010). The mean timing of rebound pain in group 1 was later than that in group 2 (15.5 > 9.3 h, p  4.0, p = 0.001). Arthroscopy-guided SSNB combined with ultrasound-guided ISB resulted in lower visual analogue scale pain scores at 3-24 and 48 h post-operatively, and higher patient satisfaction scores at 6-36 h post-operatively with the attenuated rebound pain compared to scores in patients who received ultrasound-guided ISB alone after arthroscopic rotator cuff repair. The combined blocks may relieve post-operative pain more effectively than the single block within 48 h after arthroscopic cuff repair. Randomized controlled trial, Level I. ClinicalTrials.gov Identifier: NCT02424630.

  8. Ultrasound techniques in the evaluation of the mediastinum, part I

    DEFF Research Database (Denmark)

    Dietrich, Christoph Frank; Annema, Jouke Tabe; Clementsen, Paul

    2015-01-01

    Ultrasound imaging has gained importance in pulmonary medicine over the last decades including conventional transcutaneous ultrasound (TUS), endoscopic ultrasound (EUS), and endobronchial ultrasound (EBUS). Mediastinal lymph node staging affects the management of patients with both operable and i...

  9. Endoscopically guided removal of cloacal calculi in three African spurred tortoises (Geochelone sulcata).

    Science.gov (United States)

    Mans, Christoph; Sladky, Kurt K

    2012-04-01

    3 female African spurred tortoises (Geochelone sulcata) of various body weights (0.22, 0.77, and 2.86 kg [0.48, 1.69, and 6.29 lb]) were examined because of reduced food intake and lack of fecal output. Owners reported intermittent tenesmus in 2 of the tortoises. Physical examinations revealed no clinically important abnormalities in the tortoises. Cloacal calculi were diagnosed on the basis of radiography and cloacoscopy in all 3 tortoises. One tortoise had another calculus in the urinary bladder. Tortoises were anesthetized, and cloacal calculi were removed by use of a cutting burr (plain-fissure cutting burr and a soft tissue protector mounted to a dental handpiece that had a low-speed motor and a straight nose cone) and warm water irrigation with endoscopic guidance. Complete removal of calculus fragments was achieved by use of forceps and irrigation. In 1 tortoise, removal of the cloacal calculus was staged (2 separate procedures). In another tortoise, a second cloacal calculus (which had been located in the urinary bladder during the first examination) was successfully removed 25 days after removal of the first calculus. All 3 tortoises recovered uneventfully, and serious complications secondary to removal of the cloacal calculi were not detected. Cloacoscopy combined with the use of a low-speed dental drill and warm water irrigation should be considered a simple, safe, and nontraumatic treatment option for removal of obstructive cloacal calculi in tortoises.

  10. Endoscopic treatment for pancreatic diseases: Needle-knife-guided cannulation via the minor papilla.

    Science.gov (United States)

    Wang, Wei; Gong, Biao; Jiang, Wei-Song; Liu, Lei; Bielike, Kouken; Xv, Bin; Wu, Yun-Lin

    2015-05-21

    To determine the efficacy and safety of meticulous cannulation by needle-knife. Three needle-knife procedures were used to facilitate cannulation in cases when standard cannulation techniques failed. A total of 104 cannulations via the minor papilla attempted in 74 patients at our center between January 2008 and June 2014 were retrospectively reviewed. Standard methods were successful in 79 cannulations. Of the 25 cannulations that could not be performed by standard methods, 19 were performed by needle-knife, while 17 (89.5%) were successful. Needle-knife use improved the success rate of cannulation [76.0%, 79/104 vs 92.3%, (79 + 17)/104; P = 0.001]. When the 6 cases not appropriate for needle-knife cannulation were excluded, the success rate was improved further (80.6%, 79/98 vs 98.0%, 96/98; P = 0.000). There were no significant differences in the rates of post-endoscopic retrograde cholangiopancreatography adverse events between the group using standard methods alone and the group using needle-knife after failure of standard methods (4.7% vs 10.5%, P = 0.301). The needle-knife procedure may be an alternative method for improving the success rate of cannulation via the minor papilla, particularly when standard cannulation has failed.

  11. Ultrasound-Guided Greater Occipital Nerve Blocks and Pulsed Radiofrequency Ablation for Diagnosis and Treatment of Occipital Neuralgia

    OpenAIRE

    VanderHoek, Matthew David; Hoang, Hieu T; Goff, Brandon

    2013-01-01

    Occipital neuralgia is a condition manifested by chronic occipital headaches and is thought to be caused by irritation or trauma to the greater occipital nerve (GON). Treatment for occipital neuralgia includes medications, nerve blocks, and pulsed radiofrequency ablation (PRFA). Landmark-guided GON blocks are the mainstay in both the diagnosis and treatment of occipital neuralgia. Ultrasound is being utilized more and more in the chronic pain clinic to guide needle advancement when performing...

  12. The ultrasound-guided retrolaminar block: volume-dependent injectate distribution

    Directory of Open Access Journals (Sweden)

    Damjanovska M

    2018-02-01

    Full Text Available Marija Damjanovska,1 Tatjana Stopar Pintaric,1,2 Erika Cvetko,2 Kamen Vlassakov3 1Clinical Department of Anesthesiology and Intensive Therapy, University Medical Centre Ljubljana, Ljubljana, Slovenia; 2Institute of Anatomy, Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia; 3Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, USA Purpose: The ultrasound-guided retrolaminar block is one of the newer and simpler alternatives to the traditional, often technically challenging, paravertebral (PV block. Its feasibility, safety, and efficacy have already been clinically demonstrated in patients with multiple rib fractures using higher volumes of local anesthetic, when compared with the traditional approach. The primary aim of this observational anatomical study was to assess the spread of local anesthetic from the retrolaminar injection point to the PV space and its volume dependence. Second, we assessed the incidence of epidural and contralateral PV spread in the both groups.Methods: Ten fresh porcine cadavers were randomized into 2 groups (n=5 each to receive ultrasound-guided retrolaminar injections at Th4-Th5 level with either 10 mL (low-volume group or 30 mL (high-volume group of 2% lidocaine and methylene blue mixture. After the procedure, the cadavers were dissected and frozen. Cross-section cuts (~1 cm thick were performed to evaluate the injectate spread.Results: In the high-volume group, injectate spread from the retrolaminar to the PV space was observed in all specimens (5 out of 5; 100%, while in the low-volume group, no apparent spread to the PV space was found (0 out of 5; 0%. No epidural or contralateral PV spread was observed in any of the specimens.Conclusion: Following ultrasound-guided retrolaminar injections in fresh porcine cadavers, injectate spread from the retrolaminar tissue plane to the PV space is strongly volume dependent

  13. A randomized comparison between costoclavicular and paracoracoid ultrasound-guided infraclavicular block for upper limb surgery.

    Science.gov (United States)

    Leurcharusmee, Prangmalee; Elgueta, Maria Francisca; Tiyaprasertkul, Worakamol; Sotthisopha, Thitipan; Samerchua, Artid; Gordon, Aida; Aliste, Julian; Finlayson, Roderick J; Tran, De Q H

    2017-06-01

    This two-centre randomized trial compared costoclavicular and paracoracoid ultrasound-guided infraclavicular brachial plexus block in patients undergoing upper limb surgery. We hypothesized that both techniques would result in similar onset times and designed the study as an equivalence trial. Ninety patients undergoing upper limb surgery at or distal to the elbow were randomly allocated to receive a costoclavicular (n = 45) or paracoracoid (n = 45) ultrasound-guided infraclavicular brachial plexus block. Both groups received a 35-mL mixture of 1% lidocaine-0.25% bupivacaine with epinephrine 5 µg·mL -1 . In the costoclavicular group, local anesthetic was injected into the costoclavicular space in the middle of the three cords of the brachial plexus. In the paracoracoid group, local anesthetic was deposited dorsal to the axillary artery in the lateral infraclavicular fossa. A blinded observer recorded the block onset time (primary endpoint), success rate (i.e., surgical anesthesia), block-related pain scores, as well as the incidence of hemidiaphragmatic paralysis. Performance time and the number of needle passes were also recorded during the performance of the block. The total anesthesia-related time was defined as the sum of the performance and onset times. The mean (SD) onset times were comparable between the costoclavicular and paracoracoid groups [16.0 (7.5) min vs 16.8 (6.2) min, respectively; mean difference, 0.8; 95% confidence interval, -2.3 to 3.8; P = 0.61]. Furthermore, no intergroup differences were found in terms of performance time (P = 0.09), total anesthesia-related time (P = 0.90), surgical anesthesia (P > 0.99), and hemidiaphragmatic paralysis (P > 0.99). The paracoracoid technique required marginally fewer median [interquartile range] needle passes than the costoclavicular technique (2 [1-4] vs 2 [1-6], respectively; P = 0.048); however, procedural pain was comparable between the two study groups. Costoclavicular and paracoracoid ultrasound-guided

  14. Minimum Effective Volume of Lidocaine for Ultrasound-Guided Costoclavicular Block.

    Science.gov (United States)

    Sotthisopha, Thitipan; Elgueta, Maria Francisca; Samerchua, Artid; Leurcharusmee, Prangmalee; Tiyaprasertkul, Worakamol; Gordon, Aida; Finlayson, Roderick J; Tran, De Q

    This dose-finding study aimed to determine the minimum effective volume in 90% of patients (MEV90) of lidocaine 1.5% with epinephrine 5 μg/mL for ultrasound-guided costoclavicular block. Using an in-plane technique and a lateral-to-medial direction, the block needle was positioned in the middle of the 3 cords of the brachial plexus in the costoclavicular space. The entire volume of lidocaine was deposited in this location. Dose assignment was carried out using a biased-coin-design up-and-down sequential method, where the total volume of local anesthetic administered to each patient depended on the response of the previous one. In case of failure, the next subject received a higher volume (defined as the previous volume with an increment of 2.5 mL). If the previous patient had a successful block, the next subject was randomized to a lower volume (defined as the previous volume with a decrement of 2.5 mL), with a probability of b = 0.11, or the same volume, with a probability of 1 - b = 0.89. Success was defined, at 30 minutes, as a minimal score of 14 of 16 points using a sensorimotor composite scale. Patients undergoing surgery of the elbow, forearm, wrist, or hand were prospectively enrolled until 45 successful blocks were obtained. This clinical trial was registered with ClinicalTrials.gov (ID NCT02932670). Fifty-seven patients were included in the study. Using isotonic regression and bootstrap confidence interval, the MEV90 for ultrasound-guided costoclavicular block was estimated to be 34.0 mL (95% confidence interval, 33.4-34.4 mL). All patients with a minimal composite score of 14 points at 30 minutes achieved surgical anesthesia intraoperatively. For ultrasound-guided costoclavicular block, the MEV90 of lidocaine 1.5% with epinephrine 5 μg/mL is 34 mL. Further dose-finding studies are required for other concentrations of lidocaine, other local anesthetic agents, and multiple-injection techniques.

  15. [Clinical application of ultrasound guided Fogarty balloon catheter in arterial crisis].

    Science.gov (United States)

    Li, Xiaodong; Wang, Pei; Yu, Changyu; Yan, Xiaowei; Yin, Jing

    2017-10-01

    To explore the effectiveness of arterial crisis after replantation of limb treated by ultrasound guided Fogarty balloon catheter. Between January 2012 and July 2016, 27 patients suffered from arterial crisis after replantation of limb were treated with ultrasound guided Fogarty balloon catheter combined with thrombolytic anticoagulant. There were 18 males and 9 females with the age of 19-51 years (mean, 32 years). The limb mutilation position was at knee joint in 3 cases, lower limb in 9 cases, ankle joint in 6 cases, elbow joint in 2 cases, forearm in 4 cases, and wrist joint in 3 cases. The arterial crisis happened at 2.5-18 hours (mean, 7.5 hours) after limb replantation surgery. Color doppler ultrasonography was used to diagnose the arterial thrombosis, finally the anastomotic thrombosis were found in 16 cases, non-anastomotic thrombosis in 7 cases, and combined thrombosis in 4 cases. All the thrombosis were deteced in the arteries with the length of 0.8-3.9 cm. No complication such as vascular perforation, rupture, air embolism, thromboembolism, wound infection, or sepsis happened after operation. Arterial crisis occurred again in 3 cases at 1.5-13.5 hours after limb replantation and treated by arterial exploration, 1 case was treated successfully; 2 cases had arterial occlusion and partial necrosis of limb, and got amputation treatment at last. The rest 24 cases survived with the incision healing by first stage. In the 24 cases, 1 case suffered from acute myonephropathic metabolic syndrome and corrected after hemodialysis; 1 case suffered from acute liver functional damage and corrected by comprehensive treatment of internal medicine. The 24 patients were followed up 7-38 months (mean, 11 months). At last follow-up, blood supply of the limb was good with normal skin temperature and improved sense of feeling, activity, and swelling. According to Chinese Medical Association of hand surgery to the upper extremity function assessment standard, the results were

  16. Ultrasound-Guided Fine-Needle Aspiration Biopsy of Multiple Thyroid Nodules

    International Nuclear Information System (INIS)

    Kim, Ji Dae; Bae, Il Hun; Lee, Seung Young; Han, Gi Seok; Cha, Sang Hun; Kim, Sung Jin; Park, Kil Sun; Koong, Sung Soo; Lee, Ok Jun

    2006-01-01

    To standardize the number of nodules which necessitates ultrasound-guided, fine-needle, aspiration biopsy in patients who have multiple thyroid nodules with the same sonographic characteristics as each other. From February, 2002 to March, 2004, among patients whose diagnosis was confirmed by ultrasound-guided, fine-needle, aspiration biopsy, 545 nodules of 203 patients were found in sonography with more than two thyroid nodules. Each thyroid gland nodule was classified on a score from 0 to 2 points on the basis of the following 5 characteristics: internal content, margin, echogenicity, shape and calcification in sonography. When the score of all characteristics was the same, by deciding on nodules with the same sonographic characteristics and with the score of at least one characteristic being different, we divided the nodules with different sonographic characteristics in a patient. By methods such as given in the preceding descriptions, patients with multiple thyroid nodules were separated into two groups: one in which all nodules had the same sonographic characteristics and another in which nodules have at least one different sonographic characteristic. Then, each pathologic result was searched for the same case and different case in each patient group. Among the 203 patients who were diagnosed with multiple thyroid nodules in ultrasonography, 79 patients (38.9%) had nodules with the same ultrasonographic characteristics and 124 patients (61.1%) had nodules with at least one different ultrasonographic characteristic. All 79 patient's nodules with the same ultrasonographic characteristics in each patient showed the same pathologic result in all cases (100.0%) and there was no case showing a different pathologic result. Otherwise, among the 124 patient's nodules with different ultrasonographic characteristics, each patient showed the same pathologic result in 111 (89.5%) and different pathologic result in 13 (10.5%). In patients who have multiple thyroid nodules

  17. The integration of 18-fluoro-deoxy-glucose positron emission tomography and endoscopic ultrasound in the treatment-planning process for esophageal carcinoma

    International Nuclear Information System (INIS)

    Konski, Andre; Doss, Mohan; Milestone, Barton; Haluszka, Oleh; Hanlon, Alexandra; Freedman, Gary; Adler, Lee

    2005-01-01

    Purpose: Accurate delineation of the gross tumor volume (GTV) is important in radiation therapy treatment planning. We evaluated the impact of PET and endoscopic ultrasound (EUS) compared with CT simulation in the planning of radiation fields for patients with esophageal carcinoma. Material and methods: Twenty-five patients presenting with esophageal carcinoma for radiation therapy underwent PET scans in the treatment position after conventional CT simulation. Patients underwent PET/CT scanning after being injected with 10 to 20 mCi of [F-18]-2-deoxy-2-fluro-D-glucose. The length of the abnormality seen on the CT portion of the PET/CT scan vs. the PET scan alone was determined independently by 2 separate investigators. The length of the GTV and detection of regional adenopathy by PET was also correlated with EUS in 18 patients. Of the 18 patients who had EUS, 2 had T2 tumors and 16 had T3 tumors. Eighteen patients had adenocarcinoma and 7 had squamous cell carcinoma. Nine tumors were located at the gastroesophageal junction, 8 at the lower esophagus, 7 in the middle esophagus, and 1 in the cervical esophagus. The PET scans were reviewed to determine the length of the abnormality by use of a standard uptake value (SUV) of 2.5 to delineate the tumor extent. Results: The mean length of the cancer was 5.4 cm (95% CI 4.4-6.4 cm) as determined by PET scan, 6.77 cm (95% CI, 5.6-7.9 cm) as determined by CT scan, and 5.1 cm (95% CI, 4.0-6.1 cm) for the 22 patients who had endoscopy. The length of the tumors was significantly longer as measured by CT scans compared with PET scans (p = 0.0063). EUS detected significantly more patients with periesophageal and celiac lymphadenopathy compared to PET and CT. The SUV of the esophageal tumors was higher in patients with peri-esophageal lymphadenopathy identified on PET scans. Conclusion: Endoscopic ultrasound and PET scans can add additional information to aid the radiation oncologist's ability to precisely identify the GTV in

  18. MO-DE-202-01: Image-<