WorldWideScience

Sample records for endoscopic autofluorescence microspectro-imaging

  1. Endoscopic tri-modal imaging for detection of early neoplasia in Barrett's oesophagus: a multi-centre feasibility study using high-resolution endoscopy, autofluorescence imaging and narrow band imaging incorporated in one endoscopy system

    NARCIS (Netherlands)

    Curvers, W. L.; Singh, R.; Song, L.-M. Wong-Kee; Wolfsen, H. C.; Ragunath, K.; Wang, K.; Wallace, M. B.; Fockens, P.; Bergman, J. J. G. H. M.

    2008-01-01

    OBJECTIVE: To investigate the diagnostic potential of endoscopic tri-modal imaging and the relative contribution of each imaging modality (i.e. high-resolution endoscopy (HRE), autofluorescence imaging (AFI) and narrow-band imaging (NBI)) for the detection of early neoplasia in Barrett's oesophagus.

  2. Comparison of Narrowband Imaging with Autofluorescence Imaging for Endoscopic Visualization of Superficial Squamous Cell Carcinoma Lesions of the Esophagus

    Directory of Open Access Journals (Sweden)

    Haruhisa Suzuki

    2012-01-01

    Full Text Available Aim. To compare narrowband imaging (NBI and autofluorescence imaging (AFI endoscopic visualization for identifying superficial esophageal squamous cell carcinoma (SCC. Methods. Twenty-four patients with superficial esophageal carcinomas diagnosed at previous hospitals were enrolled in this study. Lesions were initially detected using white-light endoscopy and then observed with both NBI and AFI. Endoscopic images documented each method, and three endoscopists experienced in esophageal imaging retrospectively reviewed respective images of histologically confirmed esophageal SCCs. Images were assessed for quality in identifying superficial SCCs and rated as excellent, fair, or poor by the three reviewers with interobserver agreement calculated using kappa (κ statistics. Results. Thirty-one lesions histologically confirmed as superficial esophageal SCCs were detected in 24 patients. NBI images of 27 lesions (87% were rated as excellent, three as fair, and one as poor compared to AFI images of 19 lesions (61% rated as excellent, 10 as fair and two as poor (P<0.05. Moderate interobserver agreement (κ=0.42, 95% CI 0.24–0.60 resulted in NBI while fair agreement (κ=0.35, 95% CI 0.18–0.51 was achieved using AFI. Conclusion. NBI may be more effective than AFI for visualization of esophageal SCC.

  3. Feasibility for detection of autofluorescent signatures in rat organs using a novel excitation-scanning hyperspectral imaging system

    Science.gov (United States)

    Favreau, Peter F.; Deal, Joshua A.; Weber, David S.; Rich, Thomas C.; Leavesley, Silas J.

    2016-04-01

    The natural fluorescence (autofluorescence) of tissues has been noted as a biomarker for cancer for several decades. Autofluorescence contrast between tumors and healthy tissues has been of significant interest in endoscopy, leading to development of autofluorescence endoscopes capable of visualizing 2-3 fluorescence emission wavelengths to achieve maximal contrast. However, tumor detection with autofluorescence endoscopes is hindered by low fluorescence signal and limited quantitative information, resulting in prolonged endoscopic procedures, prohibitive acquisition times, and reduced specificity of detection. Our lab has designed a novel excitation-scanning hyperspectral imaging system with high fluorescence signal detection, low acquisition time, and enhanced spectral discrimination. In this study, we surveyed a comprehensive set of excised tissues to assess the feasibility of detecting tissue-specific pathologies using excitation-scanning. Fresh, untreated tissue specimens were imaged from 360 to 550 nm on an inverted fluorescence microscope equipped with a set of thin-film tunable filters (Semrock, A Unit of IDEX). Images were subdivided into training and test sets. Automated endmember extraction (ENVI 5.1, Exelis) with PCA identified endmembers within training images of autofluorescence. A spectral library was created from 9 endmembers. The library was used for identification of endmembers in test images. Our results suggest (1) spectral differentiation of multiple tissue types is possible using excitation scanning; (2) shared spectra between tissue types; and (3) the ability to identify unique morphological features in disparate tissues from shared autofluorescent components. Future work will focus on isolating specific molecular signatures present in tissue spectra, and elucidating the contribution of these signatures in pathologies.

  4. Clinical Evaluation of Endoscopic Trimodal Imaging for the Detection and Differentiation of Colonic Polyps

    NARCIS (Netherlands)

    van den Broek, Frank J. C.; Fockens, Paul; van Eeden, Susanne; Kara, Mohammed A.; Hardwick, James C. H.; Reitsma, Johannes B.; Dekker, Evelien

    2009-01-01

    Background & Aims: Endoscopic trimodal imaging (ETMI) incorporates high-resolution endoscopy (HRE) and autofluorescence imaging (AFI) for adenoma detection, and narrow-band imaging (NBI) for differentiation of adenomas from nonneoplastic polyps. The aim of this study was to compare AFI with HRE for

  5. Characterization of tissue autofluorescence in Barrett's esophagus by confocal fluorescence microscopy

    NARCIS (Netherlands)

    Kara, M. A.; DaCosta, R. S.; Streutker, C. J.; Marcon, N. E.; Bergman, J. J. G. H. M.; Wilson, B. C.

    2007-01-01

    High grade dysplasia and early cancer in Barrett's esophagus can be distinguished in vivo by endoscopic autofluorescence point spectroscopy and imaging from non-dysplastic Barrett's mucosa. We used confocal fluorescence microscopy for ex vivo comparison of autofluorescence in non-dysplastic and

  6. Optimized endoscopic autofluorescence spectroscopy for the identification of premalignant lesions in Barrett's oesophagus.

    Science.gov (United States)

    Holz, Jasmin A; Boerwinkel, David F; Meijer, Sybren L; Visser, Mike; van Leeuwen, Ton G; Aalders, Maurice C G; Bergman, Jacques J G H M

    2013-12-01

    Fluorescence spectroscopy has the potential to detect early cellular changes in Barrett's oesophagus before these become visible. As the technique is based on varying concentrations of intrinsic fluorophores, each with its own optimal excitation wavelength, it is important to assess the optimal excitation wavelength(s) for identification of premalignant lesions in patients with Barrett's oesophagus. The endoscopic spectroscopy system used contained five (ultra)violet light sources (λexc=369-416 nm) to generate autofluorescence during routine endoscopic surveillance. Autofluorescence spectroscopy was followed by a biopsy for histological assessment and spectra correlation. Three intensity ratios (r1, r2, r3) were calculated by dividing the area, A, under the spectral curve of selected emission wavelength ranges for each spectrum generated by each excitation wavelength λexc as follows (Equation is included in full-text article.). Double intensity ratios were calculated using two excitation wavelengths. Fifty-eight tissue areas from 22 patients were used for autofluorescence spectra analysis. Excitation with 395, 405 or 410 nm showed a significant (P≤0.0006) differentiation between intestinal metaplasia and grouped high-grade dysplasia/early carcinoma for intensity ratios r2 and r3. A sensitivity of 80.0% and specificity of 89.5% with an area under the ROC curve of 0.85 was achieved using 395 nm excitation and intensity ratio r3. Double excitation showed no additional value over single excitation. The combination of 395 nm excitation and intensity ratio r3 showed optimal conditions to discriminate nondysplastic from early neoplasia in Barrett's oesophagus.

  7. Autofluorescence-Free Live-Cell Imaging Using Terbium Nanoparticles.

    Science.gov (United States)

    Cardoso Dos Santos, M; Goetz, J; Bartenlian, H; Wong, K-L; Charbonnière, L J; Hildebrandt, N

    2018-04-18

    Fluorescent nanoparticles (NPs) have become irreplaceable tools for advanced cellular and subcellular imaging. While very bright NPs require excitation with UV or visible light, which can create strong autofluorescence of biological components, NIR-excitable NPs without autofluorescence issues exhibit much lower brightness. Here, we show the application of a new type of surface-photosensitized terbium NPs (Tb-NPs) for autofluorescence-free intracellular imaging in live HeLa cells. The combination of exceptionally high brightness, high photostability, and long photoluminecence (PL) lifetimes for highly efficient suppression of the short-lived autofluorescence allowed for time-gated PL imaging of intracellular vesicles over 72 h without toxicity and at extremely low Tb-NP concentrations down to 12 pM. Detection of highly resolved long-lifetime (ms) PL decay curves from small (∼10 μm 2 ) areas within single cells within a few seconds emphasized the unprecedented photophysical properties of Tb-NPs for live-cell imaging that extend well beyond currently available nanometric imaging agents.

  8. Autofluorescence Imaging and Spectroscopy of Human Lung Cancer

    Directory of Open Access Journals (Sweden)

    Mengyan Wang

    2016-12-01

    Full Text Available Lung cancer is one of the most common cancers, with high mortality rate worldwide. Autofluorescence imaging and spectroscopy is a non-invasive, label-free, real-time technique for cancer detection. In this study, lung tissue sections excised from patients were detected by laser scan confocal microscopy and spectroscopy. The autofluorescence images demonstrated the cellular morphology and tissue structure, as well as the pathology of stained images. Based on the spectra study, it was found that the majority of the patients showed discriminating fluorescence in tumor tissues from normal tissues. Therefore, autofluorescence imaging and spectroscopy may be a potential method for aiding the diagnosis of lung cancer.

  9. Two-photon excited autofluorescence imaging of freshly isolated frog retinas.

    Science.gov (United States)

    Lu, Rong-Wen; Li, Yi-Chao; Ye, Tong; Strang, Christianne; Keyser, Kent; Curcio, Christine A; Yao, Xin-Cheng

    2011-06-01

    The purpose of this study was to investigate cellular sources of autofluorescence signals in freshly isolated frog (Rana pipiens) retinas. Equipped with an ultrafast laser, a laser scanning two-photon excitation fluorescence microscope was employed for sub-cellular resolution examination of both sliced and flat-mounted retinas. Two-photon imaging of retinal slices revealed autofluorescence signals over multiple functional layers, including the photoreceptor layer (PRL), outer nuclear layer (ONL), outer plexiform layer (OPL), inner nuclear layer (INL), inner plexiform layer (IPL), and ganglion cell layer (GCL). Using flat-mounted retinas, depth-resolved imaging of individual retinal layers further confirmed multiple sources of autofluorescence signals. Cellular structures were clearly observed at the PRL, ONL, INL, and GCL. At the PRL, the autofluorescence was dominantly recorded from the intracellular compartment of the photoreceptors; while mixed intracellular and extracellular autofluorescence signals were observed at the ONL, INL, and GCL. High resolution autofluorescence imaging clearly revealed mosaic organization of rod and cone photoreceptors; and sub-cellular bright autofluorescence spots, which might relate to connecting cilium, was observed in the cone photoreceptors only. Moreover, single-cone and double-cone outer segments could be directly differentiated.

  10. Evaluation of skin pathologies by RGB autofluorescence imaging

    Science.gov (United States)

    Lihachev, Alexey; Plorina, Emilija V.; Derjabo, Alexander; Lange, Marta; Lihacova, Ilze

    2017-12-01

    A clinical trial on autofluorescence imaging of malignant and non-malignant skin pathologies comprising 32 basal cell carcinomas (BCC), 4 malignant melanomas (MM), 1 squamous cell carcinoma (SCC), 89 nevi, 14 dysplastic nevi, 20 hemangiomas, 23 seborrheic keratoses, 4 hyperkeratoses, 3 actinic keratoses, 3 psoriasis, 1 dematitis, 2 dermatofibromas, 5 papillofibromas, 12 lupus erythematosus, 7 purpura, 6 bruises, 5 freckles, 3 fungal infections, 1 burn, 1 tattoo, 1 age spot, 1 vitiligo, 32 postoperative scars, 8 post cream therapy BCCs, 4 post radiation therapy scars, 2 post laser therapy scars, 1 post freezing scar as well as 114 reference images of healthy skin was performed. The sequence of autofluorescence images of skin pathologies were recorded by smartphone RGB camera under continuous 405 nm LED excitation during 20 seconds with 0.5 fps. Obtained image sequences further were processed with subsequent extraction of autofluorescence intensity and photobleaching parameters.

  11. Use of fundus autofluorescence images to predict geographic atrophy progression.

    Science.gov (United States)

    Bearelly, Srilaxmi; Khanifar, Aziz A; Lederer, David E; Lee, Jane J; Ghodasra, Jason H; Stinnett, Sandra S; Cousins, Scott W

    2011-01-01

    Fundus autofluorescence imaging has been shown to be helpful in predicting progression of geographic atrophy (GA) secondary to age-related macular degeneration. We assess the ability of fundus autofluorescence imaging to predict rate of GA progression using a simple categorical scheme. Subjects with GA secondary to age-related macular degeneration with fundus autofluorescence imaging acquired at least 12 months apart were included. Rim area focal hyperautofluorescence was defined as percentage of the 500-μm-wide margin bordering the GA that contained increased autofluorescence. Rim area focal hyperautofluorescence on baseline fundus autofluorescence images was assessed and categorized depending on the extent of rim area focal hyperautofluorescence (Category 1: ≤33%; Category 2: between 33 and 67%; Category 3: ≥67%). Total GA areas at baseline and follow-up were measured to calculate change in GA progression. Forty-five eyes of 45 subjects were included; average duration of follow-up was 18.5 months. Median growth rates differed among categories of baseline rim area focal hyperautofluorescence (P = 0.01 among Categories 1, 2, and 3; P = 0.008 for Category 1 compared with Category 3, Jonckheere-Terpstra test). A simple categorical scheme that stratifies the amount of increased autofluorescence in the 500-μm margin bordering GA may be used to differentiate faster and slower progressors.

  12. Autofluorescence Imaging for Diagnosis and Follow-up of Cystoid Macular Edema

    Directory of Open Access Journals (Sweden)

    Nazanin Ebrahimiadib

    2012-01-01

    Full Text Available Lipofuscin results from digestion of photoreceptor outer segments by the retinal pigment epithelium (RPE and is the principal compound that causes RPE fluorescence during autofluorescence imaging. Absorption of the 488-nanometer blue light by macular pigments, especially by the carotenoids lutein and zeaxanthin, causes normal macular hypo-autofluorescence. Fundus autofluorescence imaging is being increasingly employed in ophthalmic practice to diagnose and monitor patients with a variety of retinal disorders. In macular edema for example, areas of hyper-autofluorescence are usually present which are postulated to be due to dispersion of macular pigments by pockets of intraretinal fluid. For this reason, the masking effect of macular pigments is reduced and the natural autofluorescence of lipofuscin can be observed without interference. In cystic types of macular edema, e.g. cystoid macular edema due to retinal vein occlusion, diabetic macular edema and post cataract surgery, hyperautofluorescent regions corresponding to cystic spaces of fluid accumulation can be identified. In addition, the amount of hyper-autofluorescence seems to correspond to the severity of edema. Hence, autofluorescence imaging, as a noninvasive technique, can provide valuable information on cystoid macular edema in terms of diagnosis, followup and efficacy of treatment.

  13. Reduced background autofluorescence for cell imaging using nanodiamonds and lanthanide chelates.

    Science.gov (United States)

    Cordina, Nicole M; Sayyadi, Nima; Parker, Lindsay M; Everest-Dass, Arun; Brown, Louise J; Packer, Nicolle H

    2018-03-14

    Bio-imaging is a key technique in tracking and monitoring important biological processes and fundamental biomolecular interactions, however the interference of background autofluorescence with targeted fluorophores is problematic for many bio-imaging applications. This study reports on two novel methods for reducing interference with cellular autofluorescence for bio-imaging. The first method uses fluorescent nanodiamonds (FNDs), containing nitrogen vacancy centers. FNDs emit at near-infrared wavelengths typically higher than most cellular autofluorescence; and when appropriately functionalized, can be used for background-free imaging of targeted biomolecules. The second method uses europium-chelating tags with long fluorescence lifetimes. These europium-chelating tags enhance background-free imaging due to the short fluorescent lifetimes of cellular autofluorescence. In this study, we used both methods to target E-selectin, a transmembrane glycoprotein that is activated by inflammation, to demonstrate background-free fluorescent staining in fixed endothelial cells. Our findings indicate that both FND and Europium based staining can improve fluorescent bio-imaging capabilities by reducing competition with cellular autofluorescence. 30 nm nanodiamonds coated with the E-selectin antibody was found to enable the most sensitive detective of E-selectin in inflamed cells, with a 40-fold increase in intensity detected.

  14. [Fundus Autofluorescence Imaging].

    Science.gov (United States)

    Schmitz-Valckenberg, S

    2015-09-01

    Fundus autofluorescence (FAF) imaging allows for non-invasive mapping of changes at the level of the retinal pigment epithelium/photoreceptor complex and of alterations of macular pigment distribution. This imaging method is based on the visualisation of intrinsic fluorophores and may be easily and rapidly used in routine patient care. Main applications include degenerative disorders of the outer retina such as age-related macular degeneration, hereditary and acquired retinal diseases. FAF imaging is particularly helpful for differential diagnosis, detection and extent of involved retinal areas, structural-functional correlations and monitoring of changes over time. Recent developments include - in addition to the original application of short wavelength light for excitation ("blue" FAF imaging) - the use of other wavelength ranges ("green" or "near-infrared" FAF imaging), widefield imaging for visualisation of peripheral retinal areas and quantitative FAF imaging. Georg Thieme Verlag KG Stuttgart · New York.

  15. Mitigating fluorescence spectral overlap in wide-field endoscopic imaging

    Science.gov (United States)

    Hou, Vivian; Nelson, Leonard Y.; Seibel, Eric J.

    2013-01-01

    Abstract. The number of molecular species suitable for multispectral fluorescence imaging is limited due to the overlap of the emission spectra of indicator fluorophores, e.g., dyes and nanoparticles. To remove fluorophore emission cross-talk in wide-field multispectral fluorescence molecular imaging, we evaluate three different solutions: (1) image stitching, (2) concurrent imaging with cross-talk ratio subtraction algorithm, and (3) frame-sequential imaging. A phantom with fluorophore emission cross-talk is fabricated, and a 1.2-mm ultrathin scanning fiber endoscope (SFE) is used to test and compare these approaches. Results show that fluorophore emission cross-talk could be successfully avoided or significantly reduced. Near term, the concurrent imaging method of wide-field multispectral fluorescence SFE is viable for early stage cancer detection and localization in vivo. Furthermore, a means to enhance exogenous fluorescence target-to-background ratio by the reduction of tissue autofluorescence background is demonstrated. PMID:23966226

  16. Autofluorescence imaging of basal cell carcinoma by smartphone RGB camera

    Science.gov (United States)

    Lihachev, Alexey; Derjabo, Alexander; Ferulova, Inesa; Lange, Marta; Lihacova, Ilze; Spigulis, Janis

    2015-12-01

    The feasibility of smartphones for in vivo skin autofluorescence imaging has been investigated. Filtered autofluorescence images from the same tissue area were periodically captured by a smartphone RGB camera with subsequent detection of fluorescence intensity decreasing at each image pixel for further imaging the planar distribution of those values. The proposed methodology was tested clinically with 13 basal cell carcinoma and 1 atypical nevus. Several clinical cases and potential future applications of the smartphone-based technique are discussed.

  17. Tryptophan autofluorescence imaging of neoplasms of the human colon

    Science.gov (United States)

    Banerjee, Bhaskar; Renkoski, Timothy; Graves, Logan R.; Rial, Nathaniel S.; Tsikitis, Vassiliki Liana; Nfonsom, Valentine; Pugh, Judith; Tiwari, Piyush; Gavini, Hemanth; Utzinger, Urs

    2012-01-01

    Detection of flat neoplasia is a major challenge in colorectal cancer screening, as missed lesions can lead to the development of an unexpected `incident' cancer prior to the subsequent endoscopy. The use of a tryptophan-related autofluorescence has been reported to be increased in murine intestinal dysplasia. The emission spectra of cells isolated from human adenocarcinoma and normal mucosa of the colon were studied and showed markedly greater emission intensity from cancerous cells compared to cells obtained from the surrounding normal mucosa. A proto-type multispectral imaging system optimized for ultraviolet macroscopic imaging of tissue was used to obtain autofluorescence images of surgical specimens of colonic neoplasms and normal mucosa after resection. Fluorescence images did not display the expected greater emission from the tumor as compared to the normal mucosa, most probably due to increased optical absorption and scattering in the tumors. Increased fluorescence intensity in neoplasms was observed however, once fluorescence images were corrected using reflectance images. Tryptophan fluorescence alone may be useful in differentiating normal and cancerous cells, while in tissues its autofluorescence image divided by green reflectance may be useful in displaying neoplasms.

  18. Demystifying autofluorescence with excitation scanning hyperspectral imaging

    Science.gov (United States)

    Deal, Joshua; Harris, Bradley; Martin, Will; Lall, Malvika; Lopez, Carmen; Rider, Paul; Boudreaux, Carole; Rich, Thomas; Leavesley, Silas J.

    2018-02-01

    Autofluorescence has historically been considered a nuisance in medical imaging. Many endogenous fluorophores, specifically, collagen, elastin, NADH, and FAD, are found throughout the human body. Diagnostically, these signals can be prohibitive since they can outcompete signals introduced for diagnostic purposes. Recent advances in hyperspectral imaging have allowed the acquisition of significantly more data in a shorter time period by scanning the excitation spectra of fluorophores. The reduced acquisition time and increased signal-to-noise ratio allow for separation of significantly more fluorophores than previously possible. Here, we propose to utilize excitation-scanning of autofluorescence to examine tissues and diagnose pathologies. Spectra of autofluorescent molecules were obtained using a custom inverted microscope (TE-2000, Nikon Instruments) with a Xe arc lamp and thin film tunable filter array (VersaChrome, Semrock, Inc.) Scans utilized excitation wavelengths from 360 nm to 550 nm in 5 nm increments. The resultant spectra were used to examine hyperspectral image stacks from various collaborative studies, including an atherosclerotic rat model and a colon cancer study. Hyperspectral images were analyzed with ENVI and custom Matlab scripts including linear spectral unmixing (LSU) and principal component analysis (PCA). Initial results suggest the ability to separate the signals of endogenous fluorophores and measure the relative concentrations of fluorophores among healthy and diseased states of similar tissues. These results suggest pathology-specific changes to endogenous fluorophores can be detected using excitationscanning hyperspectral imaging. Future work will expand the library of pure molecules and will examine more defined disease states.

  19. Relevance of wide-field autofluorescence imaging in Birdshot retinochoroidopathy: descriptive analysis of 76 eyes.

    Science.gov (United States)

    Piffer, Anne-Laure Le; Boissonnot, Michèle; Gobert, Frédéric; Zenger, Anita; Wolf, Sebastian; Wolf, Ute; Korobelnik, Jean-François; Rougier, Marie-Bénédicte

    2014-09-01

    To study and classify retinal lesions in patients with birdshot disease using wide-field autofluorescence imaging and correlate them according to patients' visual status. A multicentre study was carried out on 76 eyes of 39 patients with birdshot disease, analysing colour images and under autofluorescence using the wide-field Optomap(®) imaging system. This was combined with a complete clinical exam and analysis of the macula with OCT. In over 80% of the eyes, a chorioretinal lesion has been observed under autofluorescence with a direct correlation between the extent of the lesion and visual status. The presence of macular hypo-autofluorescence was correlated with a decreased visual acuity, due to the presence of a macular oedema, active clinical inflammation or an epiretinal membrane. The hypo-autofluorescence observed correlated with the duration of the disease and the degree of inflammation in the affected eye, indicating a secondary lesion in the pigment epithelium in relation to the choroid. The pigment epithelium was affected in a diffuse manner, as in almost 50% of the eyes the wider peripheral retina was affected. Wide-field autofluorescence imaging could appear to be a useful examination when monitoring patients, to look for areas of macular hypo-autofluorescence responsible for an irreversible loss of vision. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  20. Phasor analysis of multiphoton spectral images distinguishes autofluorescence components of in vivo human skin

    NARCIS (Netherlands)

    Fereidouni, F.; Bader, A.N.; Colonna, A.; Gerritsen, H.C.

    2014-01-01

    Skin contains many autofluorescent components that can be studied using spectral imaging. We employed a spectral phasor method to analyse two photon excited auto-fluorescence and second harmonic generation images of in vivo human skin. This method allows segmentation of images based on spectral

  1. Two-photon excited autofluorescence imaging of human retinal pigment epithelial cells

    Science.gov (United States)

    Han, Meng; Blindewald-Wittich, Almut; Holz, Frank G.; Giese, Günter; Niemz, Markolf H.; Snyder, Sarah; Sun, Hui; Yu, Jiayi; Agopov, Michael; La Schiazza, Olivier; Bille, Josef F.

    2006-01-01

    Degeneration of retinal pigment epithelial (RPE) cells severely impairs the visual function of retina photoreceptors. However, little is known about the events that trigger the death of RPE cells at the subcellular level. Two-photon excited autofluorescence (TPEF) imaging of RPE cells proves to be well suited to investigate both the morphological and the spectral characteristics of the human RPE cells. The dominant fluorophores of autofluorescence derive from lipofuscin (LF) granules that accumulate in the cytoplasm of the RPE cells with increasing age. Spectral TPEF imaging reveals the existence of abnormal LF granules with blue shifted autofluorescence in RPE cells of aging patients and brings new insights into the complicated composition of the LF granules. Based on a proposed two-photon laser scanning ophthalmoscope, TPEF imaging of the living retina may be valuable for diagnostic and pathological studies of age related eye diseases.

  2. Statistical and fractal analysis of autofluorescent myocardium images in posthumous diagnostics of acute coronary insufficiency

    Science.gov (United States)

    Boichuk, T. M.; Bachinskiy, V. T.; Vanchuliak, O. Ya.; Minzer, O. P.; Garazdiuk, M.; Motrich, A. V.

    2014-08-01

    This research presents the results of investigation of laser polarization fluorescence of biological layers (histological sections of the myocardium). The polarized structure of autofluorescence imaging layers of biological tissues was detected and investigated. Proposed the model of describing the formation of polarization inhomogeneous of autofluorescence imaging biological optically anisotropic layers. On this basis, analytically and experimentally tested to justify the method of laser polarimetry autofluorescent. Analyzed the effectiveness of this method in the postmortem diagnosis of infarction. The objective criteria (statistical moments) of differentiation of autofluorescent images of histological sections myocardium were defined. The operational characteristics (sensitivity, specificity, accuracy) of these technique were determined.

  3. Fundus autofluorescence applications in retinal imaging

    Science.gov (United States)

    Gabai, Andrea; Veritti, Daniele; Lanzetta, Paolo

    2015-01-01

    Fundus autofluorescence (FAF) is a relatively new imaging technique that can be used to study retinal diseases. It provides information on retinal metabolism and health. Several different pathologies can be detected. Peculiar AF alterations can help the clinician to monitor disease progression and to better understand its pathogenesis. In the present article, we review FAF principles and clinical applications. PMID:26139802

  4. Fundus autofluorescence applications in retinal imaging

    Directory of Open Access Journals (Sweden)

    Andrea Gabai

    2015-01-01

    Full Text Available Fundus autofluorescence (FAF is a relatively new imaging technique that can be used to study retinal diseases. It provides information on retinal metabolism and health. Several different pathologies can be detected. Peculiar AF alterations can help the clinician to monitor disease progression and to better understand its pathogenesis. In the present article, we review FAF principles and clinical applications.

  5. Iris autofluorescence in Fuchs' heterochromic uveitis.

    Science.gov (United States)

    Liu, Qian; Jia, Yading; Zhang, Suhua; Xie, Juan; Chang, Xin; Hou, Jia; Li, Gaiyun; Koch, Douglas D; Wang, Li

    2016-10-01

    To explore the characteristic autofluorescence patterns of iris depigmentation in eyes diagnosed with Fuchs' heterochromic uveitis (FHU). Near-infrared autofluorescence images and colour images of iris were taken in 21 eyes of 21 patients with FHU, 30 eyes of 15 normal subjects, 30 eyes of 15 normal age-related iris atrophy and 33 eyes of 20 patients with uveitis other than FHU. The confocal scanning laser ophthalmoscope (Heidelberg Retina Angiograph 2, HRA2) was used for melanin-related autofluorescence imaging. The indocyanine green angiography mode of HRA2 was applied for near-infrared laser imaging, and the wavelength of the excitation laser was 795 nm. Iris colour images were also taken with the slit lamp. In normal iris, moderately intense autofluorescence was noted for the pigment ruff at the pupillary border, the crests in the pupillary zone and the collarette; and there was mild autofluorescence in the ciliary zone. In eyes with age-related iris atrophy and uveitis, much less autofluorescence was seen than the healthy normal irides. In eyes with FHU, there was moderate but discontinuous autofluorescence in the pigment ruff, a petaloid pattern of autofluorescence in the pupillary zone, moderate autofluorescence in the collarette and reticular pattern of autofluorescence in the ciliary zone. Characteristic autofluorescence patterns appeared in eyes diagnosed with FHU. Near-infrared autofluorescence is a promising objective technique to document the iris changes in FHU. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  6. Fundus autofluorescence in serpiginouslike choroiditis.

    Science.gov (United States)

    Gupta, Amod; Bansal, Reema; Gupta, Vishali; Sharma, Aman

    2012-04-01

    To report the fundus autofluorescence characteristics in serpiginouslike choroiditis. Twenty-nine patients with presumed tubercular serpiginouslike choroiditis between November 2008 and January 2010 underwent fundus autofluorescence imaging during the acute stage and at regular intervals till the lesions healed. All patients received antitubercular therapy with oral corticosteroids. The autofluorescence images were compared with color fundus photography and fundus fluorescein angiography. The main outcome measure was fundus autofluorescence characteristics of lesions during the course of the disease. The pattern of fundus autofluorescence changed as the lesions evolved from the acute to the healed stage. In acute stage, the lesions showed an ill-defined halo of increased autofluorescence (hyperautofluorescence), giving it a diffuse, amorphous appearance (Stage I, acute). As the lesions began to heal, a thin rim of decreased autofluorescence (hypoautofluorescence) surrounded the lesion, defining its edges. The lesions showed predominantly hyperautofluorescence with stippled pattern (Stage II, subacute). With further healing, the hypoautofluorescence progressed and the lesion appeared predominantly hypoautofluorescent with stippled pattern (Stage III, nearly resolved). On complete healing, the lesions became uniformly hypoautofluorescent (Stage IV, completely resolved). Fundus autofluorescence highlighted the areas of disease activity and was a quick imaging tool for monitoring the course of lesions in serpiginouslike choroiditis.

  7. Spectral-domain optical coherence tomography staging and autofluorescence imaging in achromatopsia.

    Science.gov (United States)

    Greenberg, Jonathan P; Sherman, Jerome; Zweifel, Sandrine A; Chen, Royce W S; Duncker, Tobias; Kohl, Susanne; Baumann, Britta; Wissinger, Bernd; Yannuzzi, Lawrence A; Tsang, Stephen H

    2014-04-01

    IMPORTANCE Evidence is mounting that achromatopsia is a progressive retinal degeneration, and treatments for this condition are on the horizon. OBJECTIVES To categorize achromatopsia into clinically identifiable stages using spectral-domain optical coherence tomography and to describe fundus autofluorescence imaging in this condition. DESIGN, SETTING, AND PARTICIPANTS A prospective observational study was performed between 2010 and 2012 at the Edward S. Harkness Eye Institute, New York-Presbyterian Hospital. Participants included 17 patients (aged 10-62 years) with full-field electroretinography-confirmed achromatopsia. MAIN OUTCOMES AND MEASURES Spectral-domain optical coherence tomography features and staging system, fundus autofluorescence and near-infrared reflectance features and their correlation to optical coherence tomography, and genetic mutations served as the outcomes and measures. RESULTS Achromatopsia was categorized into 5 stages on spectral-domain optical coherence tomography: stage 1 (2 patients [12%]), intact outer retina; stage 2 (2 patients [12%]), inner segment ellipsoid line disruption; stage 3 (5 patients [29%]), presence of an optically empty space; stage 4 (5 patients [29%]), optically empty space with partial retinal pigment epithelium disruption; and stage 5 (3 patients [18%]), complete retinal pigment epithelium disruption and/or loss of the outer nuclear layer. Stage 1 patients showed isolated hyperreflectivity of the external limiting membrane in the fovea, and the external limiting membrane was hyperreflective above each optically empty space. On near infrared reflectance imaging, the fovea was normal, hyporeflective, or showed both hyporeflective and hyperreflective features. All patients demonstrated autofluorescence abnormalities in the fovea and/or parafovea: 9 participants (53%) had reduced or absent autofluorescence surrounded by increased autofluorescence, 4 individuals (24%) showed only reduced or absent autofluorescence, 3

  8. Geographic atrophy segmentation in infrared and autofluorescent retina images using supervised learning.

    Science.gov (United States)

    Devisetti, K; Karnowski, T P; Giancardo, L; Li, Y; Chaum, E

    2011-01-01

    Geographic Atrophy (GA) of the retinal pigment epithelium (RPE) is an advanced form of atrophic age-related macular degeneration (AMD) and is responsible for about 20% of AMD-related legal blindness in the United States. Two different imaging modalities for retinas, infrared imaging and autofluorescence imaging, serve as interesting complimentary technologies for highlighting GA. In this work we explore the use of neural network classifiers in performing segmentation of GA in registered infrared (IR) and autofluorescence (AF) images. Our segmentation achieved a performance level of 82.5% sensitivity and 92.9% specificity on a per-pixel basis using hold-one-out validation testing. The algorithm, feature extraction, data set and experimental results are discussed and shown.

  9. Enhanced depth imaging optical coherence tomography and fundus autofluorescence findings in bilateral choroidal osteoma: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Erol, Muhammet Kazim; Coban, Deniz Turgut; Ceran, Basak Bostanci; Bulut, Mehmet, E-mail: muhammetkazimerol@gmail.com [Kazim Erol. Antalya Training and Research Hospital, Ophthalmology Department, Antalya (Turkey)

    2013-11-01

    The authors present enhanced depth imaging optical coherence tomography (EDI OCT) and fundus autofluorescence (FAF) characteristics of a patient with bilateral choroidal osteoma and try to make a correlation between two imaging techniques. Two eyes of a patient with choroidal osteoma underwent complete ophthalmic examination. Enhanced depth imaging optical coherence tomography revealed a cage-like pattern, which corresponded to the calcified region of the tumor. Fundus autofluorescence imaging of the same area showed slight hyperautofluorescence. Three different reflectivity patterns in the decalcified area were defined. In the areas of subretinal fluid, outer segment elongations similar to central serous chorioretinopathy were observed. Hyperautofluorescent spots were evident in fundus autofluorescence in the same area. Calcified and decalcified portions of choroidal osteoma as well as the atrophy of choriocapillaris demonstrated different patterns with enhanced depth imaging and fundus autofluorescence imaging. Both techniques were found to be beneficial in the diagnosis and follow-up of choroidal osteoma. (author)

  10. Enhanced depth imaging optical coherence tomography and fundus autofluorescence findings in bilateral choroidal osteoma: a case report

    International Nuclear Information System (INIS)

    Erol, Muhammet Kazim; Coban, Deniz Turgut; Ceran, Basak Bostanci; Bulut, Mehmet

    2013-01-01

    The authors present enhanced depth imaging optical coherence tomography (EDI OCT) and fundus autofluorescence (FAF) characteristics of a patient with bilateral choroidal osteoma and try to make a correlation between two imaging techniques. Two eyes of a patient with choroidal osteoma underwent complete ophthalmic examination. Enhanced depth imaging optical coherence tomography revealed a cage-like pattern, which corresponded to the calcified region of the tumor. Fundus autofluorescence imaging of the same area showed slight hyperautofluorescence. Three different reflectivity patterns in the decalcified area were defined. In the areas of subretinal fluid, outer segment elongations similar to central serous chorioretinopathy were observed. Hyperautofluorescent spots were evident in fundus autofluorescence in the same area. Calcified and decalcified portions of choroidal osteoma as well as the atrophy of choriocapillaris demonstrated different patterns with enhanced depth imaging and fundus autofluorescence imaging. Both techniques were found to be beneficial in the diagnosis and follow-up of choroidal osteoma. (author)

  11. Enhanced depth imaging optical coherence tomography and fundus autofluorescence findings in bilateral choroidal osteoma: a case report

    Directory of Open Access Journals (Sweden)

    Muhammet Kazim Erol

    2013-06-01

    Full Text Available The authors present enhanced depth imaging optical coherence tomography (EDI OCT and fundus autofluorescence (FAF characteristics of a patient with bilateral choroidal osteoma and try to make a correlation between two imaging techniques. Two eyes of a patient with choroidal osteoma underwent complete ophthalmic examination. Enhanced depth imaging optical coherence tomography revealed a cage-like pattern, which corresponded to the calcified region of the tumor. Fundus autofluorescence imaging of the same area showed slight hyperautofluorescence. Three different reflectivity patterns in the decalcified area were defined. In the areas of subretinal fluid, outer segment elongations similar to central serous chorioretinopathy were observed. Hyperautofluorescent spots were evident in fundus autofluorescence in the same area. Calcified and decalcified portions of choroidal osteoma as well as the atrophy of choriocapillaris demonstrated different patterns with enhanced depth imaging and fundus autofluorescence imaging. Both techniques were found to be beneficial in the diagnosis and follow-up of choroidal osteoma.

  12. Imaging autofluorescence temporal signatures of the human ocular fundus in vivo

    Science.gov (United States)

    Papour, Asael; Taylor, Zachary; Stafsudd, Oscar; Tsui, Irena; Grundfest, Warren

    2015-11-01

    We demonstrate real-time in vivo fundus imaging capabilities of our fluorescence lifetime imaging technology for the first time. This implementation of lifetime imaging uses light emitting diodes to capture full-field images capable of showing direct tissue contrast without executing curve fitting or lifetime calculations. Preliminary results of fundus images are presented, investigating autofluorescence imaging potential of various retina biomarkers for early detection of macular diseases.

  13. Fundus autofluorescence imaging of the white dot syndromes.

    Science.gov (United States)

    Yeh, Steven; Forooghian, Farzin; Wong, Wai T; Faia, Lisa J; Cukras, Catherine; Lew, Julie C; Wroblewski, Keith; Weichel, Eric D; Meyerle, Catherine B; Sen, Hatice Nida; Chew, Emily Y; Nussenblatt, Robert B

    2010-01-01

    To characterize the fundus autofluorescence (FAF) findings in patients with white dot syndromes (WDSs). Patients with WDSs underwent ophthalmic examination, fundus photography, fluorescein angiography, and FAF imaging. Patients were categorized as having no, minimal, or predominant foveal hypoautofluorescence. The severity of visual impairment was then correlated with the degree of foveal hypoautofluorescence. Fifty-five eyes of 28 patients with WDSs were evaluated. Visual acuities ranged from 20/12.5 to hand motions. Diagnoses included serpiginous choroidopathy (5 patients), birdshot retinochoroidopathy (10), multifocal choroiditis (8), relentless placoid chorioretinitis (1), presumed tuberculosis-associated serpiginouslike choroidopathy (1), acute posterior multifocal placoid pigment epitheliopathy (1), and acute zonal occult outer retinopathy (2). In active serpiginous choroidopathy, notable hyperautofluorescence in active disease distinguished it from the variegated FAF features of tuberculosis-associated serpiginouslike choroidopathy. The percentage of patients with visual acuity impairment of less than 20/40 differed among eyes with no, minimal, and predominant foveal hypoautofluorescence (P < .001). Patients with predominant foveal hypoautofluorescence demonstrated worse visual acuity than those with minimal or no foveal hypoautofluorescence (both P < .001). Fundus autofluorescence imaging is useful in the evaluation of the WDS. Visual acuity impairment is correlated with foveal hypoautofluorescence. Further studies are needed to evaluate the precise role of FAF imaging in the WDSs.

  14. Characterization of porcine eyes based on autofluorescence lifetime imaging

    Science.gov (United States)

    Batista, Ana; Breunig, Hans Georg; Uchugonova, Aisada; Morgado, António Miguel; König, Karsten

    2015-03-01

    Multiphoton microscopy is a non-invasive imaging technique with ideal characteristics for biological applications. In this study, we propose to characterize three major structures of the porcine eye, the cornea, crystalline lens, and retina using two-photon excitation fluorescence lifetime imaging microscopy (2PE-FLIM). Samples were imaged using a laser-scanning microscope, consisting of a broadband sub-15 femtosecond (fs) near-infrared laser. Signal detection was performed using a 16-channel photomultiplier tube (PMT) detector (PML-16PMT). Therefore, spectral analysis of the fluorescence lifetime data was possible. To ensure a correct spectral analysis of the autofluorescence lifetime data, the spectra of the individual endogenous fluorophores were acquired with the 16-channel PMT and with a spectrometer. All experiments were performed within 12h of the porcine eye enucleation. We were able to image the cornea, crystalline lens, and retina at multiple depths. Discrimination of each structure based on their autofluorescence intensity and lifetimes was possible. Furthermore, discrimination between different layers of the same structure was also possible. To the best of our knowledge, this was the first time that 2PE-FLIM was used for porcine lens imaging and layer discrimination. With this study we further demonstrated the feasibility of 2PE-FLIM to image and differentiate three of the main components of the eye and its potential as an ophthalmologic technique.

  15. Hyperspectral laser-induced autofluorescence imaging of dental caries

    Science.gov (United States)

    Bürmen, Miran; Fidler, Aleš; Pernuš, Franjo; Likar, Boštjan

    2012-01-01

    Dental caries is a disease characterized by demineralization of enamel crystals leading to the penetration of bacteria into the dentine and pulp. Early detection of enamel demineralization resulting in increased enamel porosity, commonly known as white spots, is a difficult diagnostic task. Laser induced autofluorescence was shown to be a useful method for early detection of demineralization. The existing studies involved either a single point spectroscopic measurements or imaging at a single spectral band. In the case of spectroscopic measurements, very little or no spatial information is acquired and the measured autofluorescence signal strongly depends on the position and orientation of the probe. On the other hand, single-band spectral imaging can be substantially affected by local spectral artefacts. Such effects can significantly interfere with automated methods for detection of early caries lesions. In contrast, hyperspectral imaging effectively combines the spatial information of imaging methods with the spectral information of spectroscopic methods providing excellent basis for development of robust and reliable algorithms for automated classification and analysis of hard dental tissues. In this paper, we employ 405 nm laser excitation of natural caries lesions. The fluorescence signal is acquired by a state-of-the-art hyperspectral imaging system consisting of a high-resolution acousto-optic tunable filter (AOTF) and a highly sensitive Scientific CMOS camera in the spectral range from 550 nm to 800 nm. The results are compared to the contrast obtained by near-infrared hyperspectral imaging technique employed in the existing studies on early detection of dental caries.

  16. Issues in quantifying atrophic macular disease using retinal autofluorescence.

    Science.gov (United States)

    Sunness, Janet S; Ziegler, Matthias D; Applegate, Carol A

    2006-01-01

    To demonstrate the potential and limits of autofluorescence imaging in identifying and delineating areas of atrophy. Fundus photographs and infrared scanning laser ophthalmoscope (SLO) imaging, SLO macular perimetry, and SLO autofluorescence imaging results were compared for two patients with geographic atrophy (GA) from age-related macular degeneration, one patient with pigmentary alteration of the retina, and two patients with Stargardt disease. The main outcome measure in this case series was the presence of reduced autofluorescence. Drusen may become undetectable during autofluorescence imaging for some patients, allowing simple identification of areas of GA with areas of reduced autofluorescence. In other patients, drusen themselves have decreased autofluorescence, despite having intact retinal function in the retina overlying them. Some patients may have areas of reduced autofluorescence that persist for many years, without evidence of the development of atrophy. In Stargardt disease, decreased autofluorescence can easily detect and delineate areas of scotoma. Areas with mottled autofluorescence may have overlying function, but the function may not be adequate to support a fixation locus in that area. Using decreased autofluorescence to delineate areas of atrophy may be helpful in atrophic macular disorders. For GA, correlation with fundus photographs or macular perimetry findings may be necessary to differentiate between drusen and atrophy. For Stargardt disease, the nature of areas of decreased autofluorescence may help explain visual function of those areas.

  17. [PACS-based endoscope image acquisition workstation].

    Science.gov (United States)

    Liu, J B; Zhuang, T G

    2001-01-01

    A practical PACS-based Endoscope Image Acquisition Workstation is here introduced. By a Multimedia Video Card, the endoscope video is digitized and captured dynamically or statically into computer. This workstation realizes a variety of functions such as the endoscope video's acquisition and display, as well as the editing, processing, managing, storage, printing, communication of related information. Together with other medical image workstation, it can make up the image sources of PACS for hospitals. In addition, it can also act as an independent endoscopy diagnostic system.

  18. LED induced autofluorescence (LIAF) imager with eight multi-filters for oral cancer diagnosis

    Science.gov (United States)

    Huang, Ting-Wei; Cheng, Nai-Lun; Tsai, Ming-Hsui; Chiou, Jin-Chern; Mang, Ou-Yang

    2016-03-01

    Oral cancer is one of the serious and growing problem in many developing and developed countries. The simple oral visual screening by clinician can reduce 37,000 oral cancer deaths annually worldwide. However, the conventional oral examination with the visual inspection and the palpation of oral lesions is not an objective and reliable approach for oral cancer diagnosis, and it may cause the delayed hospital treatment for the patients of oral cancer or leads to the oral cancer out of control in the late stage. Therefore, a device for oral cancer detection are developed for early diagnosis and treatment. A portable LED Induced autofluorescence (LIAF) imager is developed by our group. It contained the multiple wavelength of LED excitation light and the rotary filter ring of eight channels to capture ex-vivo oral tissue autofluorescence images. The advantages of LIAF imager compared to other devices for oral cancer diagnosis are that LIAF imager has a probe of L shape for fixing the object distance, protecting the effect of ambient light, and observing the blind spot in the deep port between the gumsgingiva and the lining of the mouth. Besides, the multiple excitation of LED light source can induce multiple autofluorescence, and LIAF imager with the rotary filter ring of eight channels can detect the spectral images of multiple narrow bands. The prototype of a portable LIAF imager is applied in the clinical trials for some cases in Taiwan, and the images of the clinical trial with the specific excitation show the significant differences between normal tissue and oral tissue under these cases.

  19. Spectrally enhanced imaging of occlusal surfaces and artificial shallow enamel erosions with a scanning fiber endoscope

    Science.gov (United States)

    Zhang, Liang; Nelson, Leonard Y.; Seibel, Eric J.

    2012-07-01

    An ultrathin scanning fiber endoscope, originally developed for cancer diagnosis, was used to image dental occlusal surfaces as well as shallow artificially induced enamel erosions from human extracted teeth (n=40). Enhanced image resolution of occlusal surfaces was obtained using a short-wavelength 405-nm illumination laser. In addition, artificial erosions of varying depths were also imaged with 405-, 404-, 532-, and 635-nm illumination lasers. Laser-induced autofluorescence images of the teeth using 405-nm illumination were also obtained. Contrast between sound and eroded enamel was quantitatively computed for each imaging modality. For shallow erosions, the image contrast with respect to sound enamel was greatest for the 405-nm reflected image. It was also determined that the increased contrast was in large part due to volume scattering with a smaller component from surface scattering. Furthermore, images obtained with a shallow penetration depth illumination laser (405 nm) provided the greatest detail of surface enamel topography since the reflected light does not contain contributions from light reflected from greater depths within the enamel tissue. Multilayered Monte Carlo simulations were also performed to confirm the experimental results.

  20. [Evaluation of fundus autofluorescence in hereditary retinal diseases using Heidelberg Retina Angiograph2].

    Science.gov (United States)

    Côco, Monique; Baba, Natalia Tamie; Sallum, Juliana Maria Ferraz

    2007-01-01

    To define characteristics of the fundus autofluorescence examination, verifying usefulness in the diagnosis and care of hereditary retinal diseases. 28 patients, adults, divided equally into four groups with diagnoses of Stargardt macular dystrophy, cone dystrophy, retinitis pigmentosa and healthy volunteers for the establishment of the normality pattern. An average of nine images with the filter for fluorescein angiography was obtained for the formation of the image autofluorescence using Heidelberg Retina Angiograph2. The images of each group of patients were analyzed to verify common characteristics. The fundus autofluorescence of healthy volunteers showed the foveal area darker than the surrounding retina. The images of Stargardt macular dystrophy, in general, presented an oval central lesion, with reduced autofluorescence. The main alterations of the autofluorescence in patients with cone dystrophy were reduced foveal autofluorescence with a parafoveal ring of increased autofluorescence. In general, the images of retinitis pigmentosa showed outlying pigments with reduced autofluorescence, and of the foveal area, in some cases disorganization or reduced autofluorescence. The study showed the existence of patterns of fundus autofluorescence in the hereditary retinal diseases that allow the diagnosis and better interpretation of the pathogenesis of these diseases.

  1. Bench-top endomicroscope for visualization and imaging of nuclei using ultraviolet autofluorescence

    Science.gov (United States)

    Lin, Bevin

    The long range goal of this research was to develop autofluorescence technology and instrumentation for transition towards an in vivo endomicroscopy imaging system. This approach would provide resolution sufficient to image nuclei for real-time categorization of normal and abnormal tissue implicative of disease progression. Esophageal adenocarcinoma was the chosen model to develop this diagnostic imaging system because the heterogeneous and multifocal nature of this disease makes early diagnosis extremely challenging during the window of time when the prognosis for survival is high. The asymptomatic character of this disease generally presents at a malignant stage when removal of the esophagus has become the standard treatment. The traditional gold standard of histologic diagnosis suffers from a slow turn-around-time from tissue removal to microscopic observation, compounded by error in random biopsy sampling and tissue-processing artifacts, in addition to significant variation in pathologist diagnosis. Optical biopsy has thus been developed to alleviate the problems associated with current standard video endoscopy and histopathology. Following tremendous research in the realm of optical biopsy, some traction has been gained using confocal endomicroscopy. However, current confocal methods require contrast agents and optical sectioning in order to provide images at a cellular level. We have developed a minimally invasive imaging system using autofluorescence that highlights the short photon penetration depth of ultraviolet excitation. This approach provides cellular level resolution with a clinically relevant field of view without requiring contrast agents or optical sectioning. Optical histopathology has been demonstrated using unprocessed ex vivo human gastrointestinal tissues providing diagnostic assessment in real-time, a function imperative for improved patient care and quality of life. This robust bench-top prototype endomicroscopy system is capable of rapid

  2. FUNDUS AUTOFLUORESCENCE LIFETIMES AND CENTRAL SEROUS CHORIORETINOPATHY.

    Science.gov (United States)

    Dysli, Chantal; Berger, Lieselotte; Wolf, Sebastian; Zinkernagel, Martin S

    2017-11-01

    To quantify retinal fluorescence lifetimes in patients with central serous chorioretinopathy (CSC) and to identify disease specific lifetime characteristics over the course of disease. Forty-seven participants were included in this study. Patients with central serous chorioretinopathy were imaged with fundus photography, fundus autofluorescence, optical coherence tomography, and fluorescence lifetime imaging ophthalmoscopy (FLIO) and compared with age-matched controls. Retinal autofluorescence was excited using a 473-nm blue laser light and emitted fluorescence light was detected in 2 distinct wavelengths channels (498-560 nm and 560-720 nm). Clinical features, mean retinal autofluorescence lifetimes, autofluorescence intensity, and corresponding optical coherence tomography (OCT) images were further analyzed. Thirty-five central serous chorioretinopathy patients with a mean visual acuity of 78 ETDRS letters (range, 50-90; mean Snellen equivalent: 20/32) and 12 age-matched controls were included. In the acute stage of central serous chorioretinopathy, retinal fluorescence lifetimes were shortened by 15% and 17% in the respective wavelength channels. Multiple linear regression analysis showed that fluorescence lifetimes were significantly influenced by the disease duration (P autofluorescence lifetimes, particularly in eyes with retinal pigment epithelial atrophy, were associated with poor visual acuity. This study establishes that autofluorescence lifetime changes occurring in central serous chorioretinopathy exhibit explicit patterns which can be used to estimate perturbations of the outer retinal layers with a high degree of statistical significance.

  3. In vivo optical imaging of amblyopia: Digital subtraction autofluorescence and split-spectrum amplitude-decorrelation angiography.

    Science.gov (United States)

    Guo, Lei; Tao, Jun; Xia, Fan; Yang, Zhi; Ma, Xiaoli; Hua, Rui

    2016-09-01

    Amblyopia is a visual impairment that is attributed to either abnormal binocular interactions or visual deprivation. The retina and choroids have been shown to be involved in the development of amblyopia. The purpose of this study was to investigate the retinal and choroidal microstructural abnormalities of amblyopia using digital subtraction autofluorescence and split-spectrum amplitude-decorrelation angiography (SSADA) approaches. This prospective study included 44 eyes of 22 patients with unilateral amblyopia. All patients who received indirect ophthalmoscopy, combined depth imaging spectral domain optical coherence tomography (OCT), SSADA-OCT, and macular blue light (BL-) and near-infrared (NIR-) autofluorescences underwent pupil dilation. The subfoveal choroidal thickness (SFCT) was measured. BL- and NIR-autofluorescences were determined for all patients and used to generate subtraction images with ImageJ software. The superficial, deep layers of the retina, and inner choroid layer were required for SSADA-OCT. For the normal eyes, a regularly increasing signal was observed in the central macula based on the subtraction images. In contrast, a decreased signal for the central patch or a reduced peak was detected in 16 of 22 amblyopic eyes (72.7%). The mean SFCT of the amblyopic eyes was greater than that of the fellow normal eyes (399.25 ± 4.944 µm vs. 280.58 ± 6.491 µm, respectively, P autofluorescence. The mechanistic relationship of a thicker choroid and choroidal capillary atrophy with amblyopia remains to be described. The digital subtraction image confirmed the changes in the microstructure of the amblyopic retina as a supplementary approach to detect the progression of amblyopia. Lasers Surg. Med. 48:660-667, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  4. Wide-field spectral imaging of human ovary autofluorescence and oncologic diagnosis via previously collected probe data

    Science.gov (United States)

    Renkoski, Timothy E.; Hatch, Kenneth D.; Utzinger, Urs

    2012-03-01

    With no sufficient screening test for ovarian cancer, a method to evaluate the ovarian disease state quickly and nondestructively is needed. The authors have applied a wide-field spectral imager to freshly resected ovaries of 30 human patients in a study believed to be the first of its magnitude. Endogenous fluorescence was excited with 365-nm light and imaged in eight emission bands collectively covering the 400- to 640-nm range. Linear discriminant analysis was used to classify all image pixels and generate diagnostic maps of the ovaries. Training the classifier with previously collected single-point autofluorescence measurements of a spectroscopic probe enabled this novel classification. The process by which probe-collected spectra were transformed for comparison with imager spectra is described. Sensitivity of 100% and specificity of 51% were obtained in classifying normal and cancerous ovaries using autofluorescence data alone. Specificity increased to 69% when autofluorescence data were divided by green reflectance data to correct for spatial variation in tissue absorption properties. Benign neoplasm ovaries were also found to classify as nonmalignant using the same algorithm. Although applied ex vivo, the method described here appears useful for quick assessment of cancer presence in the human ovary.

  5. High-resolution optical coherence tomography, autofluorescence, and infrared reflectance imaging in Sjögren reticular dystrophy.

    Science.gov (United States)

    Schauwvlieghe, Pieter-Paul; Torre, Kara Della; Coppieters, Frauke; Van Hoey, Anneleen; De Baere, Elfride; De Zaeytijd, Julie; Leroy, Bart P; Brodie, Scott E

    2013-01-01

    To describe the phenotype of three cases of Sjögren reticular dystrophy in detail, including high-resolution optical coherence tomography, autofluorescence imaging, and near-infrared reflectance imaging. Two unrelated teenagers were independently referred for ophthalmologic evaluation. Both underwent a full ophthalmologic workup, including electrophysiologic and extensive imaging with spectral-domain optical coherence tomography, autofluorescence imaging, and near-infrared reflectance imaging. In addition, mutation screening of ABCA4, PRPH2, and the mitochondrial tRNA gene was performed in Patient 1. Subsequently, the teenage sister of Patient 2 was examined. Strikingly similar phenotypes were present in these three patients. Fundoscopy showed bilateral foveal pigment alterations, and a lobular network of deep retinal, pigmented deposits throughout the posterior pole, tapering toward the midperiphery, with relative sparing of the immediate perifoveal macula and peripapillary area. This network is mildly to moderately hyperautofluorescent on autofluorescence and bright on near-infrared reflectance imaging. Optical coherence tomography showed abnormalities of the retinal pigment epithelium-Bruch membrane complex, photoreceptor outer segments, and photoreceptor inner/outer segment interface. The results of retinal function test were entirely normal. No molecular cause was detected in Patient 1. Imaging suggested that the lobular network of deep retinal deposits in Sjögren reticular dystrophy is the result of accumulation of both pigment and lipofuscin between photoreceptors and retinal pigment epithelium, as well as within the retinal pigment epithelium.

  6. Fundus autofluorescence imaging in dry AMD: 2014 Jules Gonin lecture of the Retina Research Foundation.

    Science.gov (United States)

    Holz, Frank G; Steinberg, Julia S; Göbel, Arno; Fleckenstein, Monika; Schmitz-Valckenberg, Steffen

    2015-01-01

    Fundus autofluorescence (FAF) imaging allows for topographic mapping of intrisnic fluorophores in the retinal pigment epithelial cell monolayer, as well as mapping of other fluorophores that may occur with disease in the outer retina and the sub-neurosensory space. FAF imaging provides information not obtainable with other imaging modalities. Near-infrared fundus autofluorescence images can also be obtained in vivo, and may be largely melanin-derived. FAF imaging has been shown to be useful in a wide spectrum of macular and retinal diseases. The scope of applications now includes identification of diseased RPE in macular/retinal diseases, elucidating pathophysiological mechanisms, identification of early disease stages, refined phenotyping, identification of prognostic markers for disease progression, monitoring disease progression in the context of both natural history and interventional therapeutic studies, and objective assessment of luteal pigment distribution and density as well as RPE melanin distribution. Here, we review the use of FAF imaging in various phenotypic manifestations of dry AMD.

  7. Retro-mode imaging and fundus autofluorescence with scanning laser ophthalmoscope of retinal dystrophies

    Directory of Open Access Journals (Sweden)

    Maurizio Battaglia

    2012-05-01

    Full Text Available Abstract Background Retinal dystrophies display a considerably wide range of phenotypic variability, which can make diagnosis and clinical staging difficult. The aim of the study is to analyze the contribution of retro-mode imaging (RMI and fundus autofluorescence (FAF to the characterization of retinal dystrophies. Methods Eighteen consecutive patients affected by retinal dystrophies underwent a complete ophthalmological examination, including best corrected visual acuity with ETDRS charts, blue-light fundus autofluorescence, (BL-FAF, near-infrared fundus autofluorescence (NIR-FAF, and RMI. The primary outcome was the identification of abnormal patterns on RMI. The secondary outcome was the correlation with the findings on BL-FAF and NIR-FAF. Results Overall, the main feature of RMI is represented by a pseudo-3D pattern of all the lesions at the posterior pole. More specifically, any accumulation of material within the retina appears as an area of elevation of different shape and size, displaying irregular and darker borders. No precise correlations between RMI, BL-AF, and NIR-AF imaging was found. Conclusions RMI and FAF appear to be useful tools for characterizing retinal dystrophies. Non-invasive diagnostic tools may yield additional information on the clinical setting and the monitoring of the patients.

  8. Fundus autofluorescence and optical coherence tomography of congenital grouped albinotic spots.

    Science.gov (United States)

    Kim, David Y; Hwang, John C; Moore, Anthony T; Bird, Alan C; Tsang, Stephen H

    2010-09-01

    The purpose of this study was to describe the findings of fundus autofluores-cence (FAF) and optical coherence tomography in a series of patients with congenital grouped albinotic spots. Three eyes of three patients with congenital grouped albinotic spots were evaluated with FAF and optical coherence tomography imaging to evaluate the nature of the albinotic spots. In all three eyes with congenital grouped albinotic spots, FAF imaging showed autofluorescent spots corresponding to the albinotic spots seen on stereo biomicroscopy. One eye also had additional spots detected on FAF imaging that were not visible on stereo biomicroscopy or color fundus photographs. Fundus autofluorescence imaging of the spots showed decreased general autofluorescence and decreased peripheral autofluorescence surrounding central areas of retained or increased autofluorescence. Optical coherence tomography showed a disruption in signal from the hyperreflective layer corresponding to the inner and outer segment junction and increased signal backscattering from the choroid in the area of the spots. Fluorescein angiography showed early and stable hyperfluorescence of the spots without leakage. In this case series, FAF showed decreased autofluorescence of the spots consistent with focal retinal pigment epithelium atrophy or abnormal material blocking normal autofluorescence and areas of increased autofluorescence suggesting retinal pigment epithelium dysfunction. The findings of optical coherence tomography and fluorescein angiography suggest photoreceptor and retinal pigment epithelium layer abnormalities. Fundus autofluorescence and optical coherence tomography are useful noninvasive diagnostic adjuncts that can aid in the diagnosis of congenital grouped albinotic spots, help determine extent of disease, and contribute to our understanding of its pathophysiology.

  9. Identification of early cancerous lesion of esophagus with endoscopic images by hyperspectral image technique (Conference Presentation)

    Science.gov (United States)

    Huang, Shih-Wei; Chen, Shih-Hua; Chen, Weichung; Wu, I.-Chen; Wu, Ming Tsang; Kuo, Chie-Tong; Wang, Hsiang-Chen

    2016-03-01

    This study presents a method to identify early esophageal cancer within endoscope using hyperspectral imaging technology. The research samples are three kinds of endoscopic images including white light endoscopic, chromoendoscopic, and narrow-band endoscopic images with different stages of pathological changes (normal, dysplasia, dysplasia - esophageal cancer, and esophageal cancer). Research is divided into two parts: first, we analysis the reflectance spectra of endoscopic images with different stages to know the spectral responses by pathological changes. Second, we identified early cancerous lesion of esophagus by principal component analysis (PCA) of the reflectance spectra of endoscopic images. The results of this study show that the identification of early cancerous lesion is possible achieve from three kinds of images. In which the spectral characteristics of NBI endoscopy images of a gray area than those without the existence of the problem the first two, and the trend is very clear. Therefore, if simply to reflect differences in the degree of spectral identification, chromoendoscopic images are suitable samples. The best identification of early esophageal cancer is using the NBI endoscopic images. Based on the results, the use of hyperspectral imaging technology in the early endoscopic esophageal cancer lesion image recognition helps clinicians quickly diagnose. We hope for the future to have a relatively large amount of endoscopic image by establishing a hyperspectral imaging database system developed in this study, so the clinician can take this repository more efficiently preliminary diagnosis.

  10. Fundus imaging with a nasal endoscope

    Directory of Open Access Journals (Sweden)

    P Mahesh Shanmugam

    2015-01-01

    Full Text Available Wide field fundus imaging is needed to diagnose, treat, and follow-up patients with retinal pathology. This is more applicable for pediatric patients as repeated evaluation is a challenge. The presently available imaging machines though provide high definition images, but carry the obvious disadvantages of either being costly or bulky or sometimes both, which limits its usage only to large centers. We hereby report a technique of fundus imaging using a nasal endoscope coupled with viscoelastic. A regular nasal endoscope with viscoelastic coupling was placed on the cornea to image the fundus of infants under general anesthesia. Wide angle fundus images of various fundus pathologies in infants could be obtained easily with readily available instruments and without the much financial investment for the institutes.

  11. Design and validation of a near-infrared fluorescence endoscope for detection of early esophageal malignancy using a targeted imaging probe

    Science.gov (United States)

    Waterhouse, Dale J.; Joseph, James; Neves, Andre A.; di Pietro, Massimiliano; Brindle, Kevin M.; Fitzgerald, Rebecca C.; Bohndiek, Sarah E.

    2016-03-01

    Barrett's esophagus is a condition that predisposes patients to esophageal cancer. Early detection of cancer in these patients can be curative, but is confounded by a lack of contrast in white light endoscopy (WLE). Application of fluorescently-labeled lectins to the esophagus during endoscopy can more accurately delineate dysplasia emerging within Barrett's than WLE1, but strong tissue autofluorescence has limited sensitivity and dynamic range of this approach. To overcome this challenge, we synthesized a near-infrared (NIR) fluorescent lectin and have constructed a clinically translatable endoscope for simultaneous WLE and NIR imaging. An imaging fiber bundle, shielded from patient contact using a disposable catheter, relays collected light into an optical path that splits the WL reflectance and NIR emission onto two cameras for simultaneous video-rate recording. The captured images are co-registered and the honeycomb artifact arising from the fiber bundle is removed using interpolation between image points derived from individual fibers. A minimum detectable concentration of 110 nM was determined using a dilution series of IRDye800CW-lectin in black well plates. We have demonstrated the ability to use our endoscope to distinguish between different tissue types in ex vivo mouse stomachs. Future work using human ex vivo tissue specimens will determine safe illumination limits and sensitivity for dysplasia and adenocarcinoma in Barrett's esophagus, prior to commencing clinical trials.

  12. Centrifugal expansion of fundus autofluorescence patterns in Stargardt disease over time.

    Science.gov (United States)

    Cukras, Catherine A; Wong, Wai T; Caruso, Rafael; Cunningham, Denise; Zein, Wadih; Sieving, Paul A

    2012-02-01

    To study the longitudinal changes in autofluorescence in Stargardt disease to reveal aspects of disease progression not previously evident. Changes in autofluorescence reflect changing fluorophore compositions of lipofuscin and melanin in retinal pigment epithelial cells, which has been hypothesized to contribute to Stargardt disease pathogenesis. We examined the temporospatial patterns of fundus autofluorescence with excitation at both 488 nm (standard fundus autofluorescence) and 795 nm (near-infrared autofluorescence) in a longitudinal case series involving 8 eyes of 4 patients (range of follow-up, 11-57 months; mean, 39 months). Image processing was performed to analyze spatial and temporal cross-modality associations. Longitudinal fundus autofluorescence imaging of fleck lesions revealed hyperautofluorescent lesions that extended in a centrifugal direction from the fovea with time. Patterns of spread were nonrandom and followed a radial path that left behind a trail of diminishing autofluorescence. Longitudinal near-infrared autofluorescence imaging also demonstrated centrifugal lesion spread but with fewer hyperautofluorescent lesions, suggestive of more transient hyperautofluorescence and more rapid decay at longer wavelengths. Fundus autofluorescence and near-infrared autofluorescence abnormalities were spatially correlated with each other, and together they reflect systematic progressions in fleck distribution and fluorophore composition occurring during the natural history of the disease. Stargardt disease fleck lesions do not evolve randomly in location but instead follow consistent patterns of radial expansion and a systematic decay of autofluorescence that reflect changing lipofuscin and melanin compositions in retinal pigment epithelial cells. These progressive foveal-to-peripheral changes are helpful in elucidating molecular and cellular mechanisms underlying Stargardt disease and may constitute potential outcome measures in clinical trials.

  13. Multiphoton autofluorescence lifetime imaging of induced pluripotent stem cells

    Science.gov (United States)

    Uchugonova, Aisada

    2017-06-01

    The multiphoton fluorescence lifetime imaging tomograph MPTflex with its flexible 360-deg scan head, articulated arm, and tunable femtosecond laser source was employed to study induced pluripotent stem cell (iPS) cultures. Autofluorescence (AF) lifetime imaging was performed with 250-ps temporal resolution and submicron spatial resolution using time-correlated single-photon counting. The two-photon excited AF was based on the metabolic coenzymes NAD(P)H and flavin adenine dinucleotide/flavoproteins. iPS cells generated from mouse embryonic fibroblasts (MEFs) and cocultured with growth-arrested MEFs as feeder cells have been studied. Significant differences on AF lifetime signatures were identified between iPS and feeder cells as well as between their differentiating counterparts.

  14. Autofluorescence lifetime imaging during transoral robotic surgery: a clinical validation study of tumor detection (Conference Presentation)

    Science.gov (United States)

    Lagarto, João. L.; Phipps, Jennifer E.; Unger, Jakob; Faller, Leta M.; Gorpas, Dimitris; Ma, Dinglong M.; Bec, Julien; Moore, Michael G.; Bewley, Arnaud F.; Yankelevich, Diego R.; Sorger, Jonathan M.; Farwell, Gregory D.; Marcu, Laura

    2017-02-01

    Autofluorescence lifetime spectroscopy is a promising non-invasive label-free tool for characterization of biological tissues and shows potential to report structural and biochemical alterations in tissue owing to pathological transformations. In particular, when combined with fiber-optic based instruments, autofluorescence lifetime measurements can enhance intraoperative diagnosis and provide guidance in surgical procedures. We investigate the potential of a fiber-optic based multi-spectral time-resolved fluorescence spectroscopy instrument to characterize the autofluorescence fingerprint associated with histologic, morphologic and metabolic changes in tissue that can provide real-time contrast between healthy and tumor regions in vivo and guide clinicians during resection of diseased areas during transoral robotic surgery. To provide immediate feedback to the surgeons, we employ tracking of an aiming beam that co-registers our point measurements with the robot camera images and allows visualization of the surgical area augmented with autofluorescence lifetime data in the surgeon's console in real-time. For each patient, autofluorescence lifetime measurements were acquired from normal, diseased and surgically altered tissue, both in vivo (pre- and post-resection) and ex vivo. Initial results indicate tumor and normal regions can be distinguished based on changes in lifetime parameters measured in vivo, when the tumor is located superficially. In particular, results show that autofluorescence lifetime of tumor is shorter than that of normal tissue (p robot assisted cancer removal interventions.

  15. Quantitative method to assess caries via fluorescence imaging from the perspective of autofluorescence spectral analysis

    Science.gov (United States)

    Chen, Q. G.; Zhu, H. H.; Xu, Y.; Lin, B.; Chen, H.

    2015-08-01

    A quantitative method to discriminate caries lesions for a fluorescence imaging system is proposed in this paper. The autofluorescence spectral investigation of 39 teeth samples classified by the International Caries Detection and Assessment System levels was performed at 405 nm excitation. The major differences in the different caries lesions focused on the relative spectral intensity range of 565-750 nm. The spectral parameter, defined as the ratio of wavebands at 565-750 nm to the whole spectral range, was calculated. The image component ratio R/(G + B) of color components was statistically computed by considering the spectral parameters (e.g. autofluorescence, optical filter, and spectral sensitivity) in our fluorescence color imaging system. Results showed that the spectral parameter and image component ratio presented a linear relation. Therefore, the image component ratio was graded as 1.62 to quantitatively classify sound, early decay, established decay, and severe decay tissues, respectively. Finally, the fluorescence images of caries were experimentally obtained, and the corresponding image component ratio distribution was compared with the classification result. A method to determine the numerical grades of caries using a fluorescence imaging system was proposed. This method can be applied to similar imaging systems.

  16. Two-Photon Autofluorescence Imaging Reveals Cellular Structures Throughout the Retina of the Living Primate Eye.

    Science.gov (United States)

    Sharma, Robin; Williams, David R; Palczewska, Grazyna; Palczewski, Krzysztof; Hunter, Jennifer J

    2016-02-01

    Although extrinsic fluorophores can be introduced to label specific cell types in the retina, endogenous fluorophores, such as NAD(P)H, FAD, collagen, and others, are present in all retinal layers. These molecules are a potential source of optical contrast and can enable noninvasive visualization of all cellular layers. We used a two-photon fluorescence adaptive optics scanning light ophthalmoscope (TPF-AOSLO) to explore the native autofluorescence of various cell classes spanning several layers in the unlabeled retina of a living primate eye. Three macaques were imaged on separate occasions using a custom TPF-AOSLO. Two-photon fluorescence was evoked by pulsed light at 730 and 920 nm excitation wavelengths, while fluorescence emission was collected in the visible range from several retinal layers and different locations. Backscattered light was recorded simultaneously in confocal modality and images were postprocessed to remove eye motion. All retinal layers yielded two-photon signals and the heterogeneous distribution of fluorophores provided optical contrast. Several structural features were observed, such as autofluorescence from vessel walls, Müller cell processes in the nerve fibers, mosaics of cells in the ganglion cell and other nuclear layers of the inner retina, as well as photoreceptor and RPE layers in the outer retina. This in vivo survey of two-photon autofluorescence throughout the primate retina demonstrates a wider variety of structural detail in the living eye than is available through conventional imaging methods, and broadens the use of two-photon imaging of normal and diseased eyes.

  17. Imaging of Neuronal Activity in Awake Mice by Measurements of Flavoprotein Autofluorescence Corrected for Cerebral Blood Flow.

    Science.gov (United States)

    Takahashi, Manami; Urushihata, Takuya; Takuwa, Hiroyuki; Sakata, Kazumi; Takado, Yuhei; Shimizu, Eiji; Suhara, Tetsuya; Higuchi, Makoto; Ito, Hiroshi

    2017-01-01

    Green fluorescence imaging (e.g., flavoprotein autofluorescence imaging, FAI) can be used to measure neuronal activity and oxygen metabolism in living brains without expressing fluorescence proteins. It is useful for understanding the mechanism of various brain functions and their abnormalities in age-related brain diseases. However, hemoglobin in cerebral blood vessels absorbs green fluorescence, hampering accurate assessments of brain function in animal models with cerebral blood vessel dysfunctions and subsequent cerebral blood flow (CBF) alterations. In the present study, we developed a new method to correct FAI signals for hemoglobin-dependent green fluorescence reductions by simultaneous measurements of green fluorescence and intrinsic optical signals. Intrinsic optical imaging enabled evaluations of light absorption and scatters by hemoglobin, which could then be applied to corrections of green fluorescence intensities. Using this method, enhanced flavoprotein autofluorescence by sensory stimuli was successfully detected in the brains of awake mice, despite increases of CBF, and hemoglobin interference. Moreover, flavoprotein autofluorescence could be properly quantified in a resting state and during sensory stimulation by a CO 2 inhalation challenge, which modified vascular responses without overtly affecting neuronal activities. The flavoprotein autofluorescence signal data obtained here were in good agreement with the previous findings from a condition with drug-induced blockade of cerebral vasodilation, justifying the current assaying methodology. Application of this technology to studies on animal models of brain diseases with possible changes of CBF, including age-related neurological disorders, would provide better understanding of the mechanisms of neurovascular coupling in pathological circumstances.

  18. Fundus autofluorescence in chronic essential hypertension.

    Science.gov (United States)

    Ramezani, Alireza; Saberian, Peyman; Soheilian, Masoud; Parsa, Saeed Alipour; Kamali, Homayoun Koohi; Entezari, Morteza; Shahbazi, Mohammad-Mehdi; Yaseri, Mehdi

    2014-01-01

    To evaluate fundus autofluorescence (FAF) changes in patients with chronic essential hypertension (HTN). In this case-control study, 35 eyes of 35 patients with chronic essential HTN (lasting >5 years) and 31 eyes of 31 volunteers without history of HTN were included. FAF pictures were taken from right eyes of all cases with the Heidelberg retina angiography and then were assessed by two masked retinal specialists. In total, FAF images including 35 images of hypertensive patients and 31 pictures of volunteers, three apparently abnormal patterns were detected. A ring of hyper-autofluorescence in the central macula (doughnut-shaped) was observed in 9 (25.7%) eyes of the hypertensive group but only in 2 (6.5%) eyes of the control group. This difference was statistically significant (P = 0.036) between two groups. Hypo- and/or hyper-autofluorescence patches outside the fovea were the other sign found more in the hypertensive group (22.9%) than in the control group (6.5%); however, the difference was not statistically significant (P = 0.089). The third feature was hypo-autofluorescence around the disk noticed in 11 (31.4%) eyes of hypertensive patients compared to 8 (25.8%) eyes of the controls (P = 0.615). A ring of hyper-autofluorescence in the central macula forming a doughnut-shaped feature may be a FAF sign in patients with chronic essential HTN.

  19. Fundus Autofluorescence in Chronic Essential Hypertension

    Directory of Open Access Journals (Sweden)

    Alireza Ramezani

    2014-01-01

    Full Text Available Purpose: To evaluate fundus autofluorescence (FAF changes in patients with chronic essential hypertension (HTN. Methods: In this case-control study, 35 eyes of 35 patients with chronic essential HTN (lasting >5 years and 31 eyes of 31 volunteers without history of HTN were included. FAF pictures were taken from right eyes of all cases with the Heidelberg retina angiography and then were assessed by two masked retinal specialists. Results: In total, FAF images including 35 images of hypertensive patients and 31 pictures of volunteers, three apparently abnormal patterns were detected. A ring of hyper-autofluorescence in the central macula (doughnut-shaped was observed in 9 (25.7% eyes of the hypertensive group but only in 2 (6.5% eyes of the control group. This difference was statistically significant (P = 0.036 between two groups. Hypo- and/or hyper-autofluorescence patches outside the fovea were the other sign found more in the hypertensive group (22.9% than in the control group (6.5%; however, the difference was not statistically significant (P = 0.089. The third feature was hypo-autofluorescence around the disk noticed in 11 (31.4% eyes of hypertensive patients compared to 8 (25.8% eyes of the controls (P = 0.615. Conclusion: A ring of hyper-autofluorescence in the central macula forming a doughnut-shaped feature may be a FAF sign in patients with chronic essential HTN.

  20. State of the art in advanced endoscopic imaging for the detection and evaluation of dysplasia and early cancer of the gastrointestinal tract

    Directory of Open Access Journals (Sweden)

    Coda S

    2014-05-01

    Full Text Available Sergio Coda,1,2 Andrew V Thillainayagam1,2 1Section of Gastroenterology and Hepatology, Department of Medicine and Photonics Group, Department of Physics, Imperial College London, London, UK; 2Endoscopy Unit, Charing Cross Hospital, Imperial College Healthcare NHS Trust, London, UK Abstract: Ideally, endoscopists should be able to detect, characterize, and confirm the nature of a lesion at the bedside, minimizing uncertainties and targeting biopsies and resections only where necessary. However, under conventional white-light inspection – at present, the sole established technique available to most of humanity – premalignant conditions and early cancers can frequently escape detection. In recent years, a range of innovative techniques have entered the endoscopic arena due to their ability to enhance the contrast of diseased tissue regions beyond what is inherently possible with standard white-light endoscopy equipment. The aim of this review is to provide an overview of the state-of-the-art advanced endoscopic imaging techniques available for clinical use that are impacting the way precancerous and neoplastic lesions of the gastrointestinal tract are currently detected and characterized at endoscopy. The basic instrumentation and the physics behind each method, followed by the most influential clinical experience, are described. High-definition endoscopy, with or without optical magnification, has contributed to higher detection rates compared with white-light endoscopy alone and has now replaced ordinary equipment in daily practice. Contrast-enhancement techniques, whether dye-based or computed, have been combined with white-light endoscopy to further improve its accuracy, but histology is still required to clarify the diagnosis. Optical microscopy techniques such as confocal laser endomicroscopy and endocytoscopy enable in vivo histology during endoscopy; however, although of invaluable assistance for tissue characterization, they have not

  1. Fluorescence and Spectral Imaging

    Directory of Open Access Journals (Sweden)

    Ralph S. DaCosta

    2007-01-01

    Full Text Available Early identification of dysplasia remains a critical goal for diagnostic endoscopy since early discovery directly improves patient survival because it allows endoscopic or surgical intervention with disease localized without lymph node involvement. Clinical studies have successfully used tissue autofluorescence with conventional white light endoscopy and biopsy for detecting adenomatous colonic polyps, differentiating benign hyperplastic from adenomas with acceptable sensitivity and specificity. In Barrett's esophagus, the detection of dysplasia remains problematic because of background inflammation, whereas in the squamous esophagus, autofluorescence imaging appears to be more dependable. Point fluorescence spectroscopy, although playing a crucial role in the pioneering mechanistic development of fluorescence endoscopic imaging, does not seem to have a current function in endoscopy because of its nontargeted sampling and suboptimal sensitivity and specificity. Other point spectroscopic modalities, such as Raman spectroscopy and elastic light scattering, continue to be evaluated in clinical studies, but still suffer the significant disadvantages of being random and nonimaging. A recent addition to the fluorescence endoscopic imaging arsenal is the use of confocal fluorescence endomicroscopy, which provides real-time optical biopsy for the first time. To improve detection of dysplasia in the gastrointestinal tract, a new and exciting development has been the use of exogenous fluorescence contrast probes that specifically target a variety of disease-related cellular biomarkers using conventional fluorescent dyes and novel potent fluorescent nanocrystals (i.e., quantum dots. This is an area of great promise, but still in its infancy, and preclinical studies are currently under way.

  2. Autofluorescence imaging system to discriminate and quantify the distribution of benthic cyanobacteria and diatoms

    DEFF Research Database (Denmark)

    Carreira, Cátia; Staal, Marc Jaap; Middelboe, Mathias

    2015-01-01

    successfully to (mixed) laboratory cultures as well as natural photosynthetic microbial mats. Cultures of the diatom Nitzschia capitellata and the cyanobacterium Geitlerinema sp. showed close correlation between autofluorescence and cell abundance. This simple and cheap imaging system allows fast observations...

  3. The reduction of retinal autofluorescence caused by light exposure.

    Science.gov (United States)

    Morgan, Jessica I W; Hunter, Jennifer J; Merigan, William H; Williams, David R

    2009-12-01

    A prior study showed that long exposure to 568-nm light at levels below the maximum permissible exposure safety limit produces retinal damage preceded by a transient reduction in the autofluorescence of retinal pigment epithelial (RPE) cells in vivo. The present study shows how the effects of exposure power and duration combine to produce this autofluorescence reduction and find the minimum exposure causing a detectable autofluorescence reduction. Macaque retinas were imaged using a fluorescence adaptive optics scanning laser ophthalmoscope to resolve individual RPE cells in vivo. The retina was exposed to 568-nm light over a square subtending 0.5 degrees with energies ranging from 1 to 788 J/cm(2), where power and duration were independently varied. In vivo exposures of 5 J/cm(2) and higher caused an immediate decrease in autofluorescence followed by either full autofluorescence recovery (exposures or= 247 J/cm(2)). No significant autofluorescence reduction was observed for exposures of 2 J/cm(2) and lower. Reciprocity of exposure power and duration held for the exposures tested, implying that the total energy delivered to the retina, rather than its distribution in time, determines the amount of autofluorescence reduction. That reciprocity held is consistent with a photochemical origin, which may or may not cause retinal degeneration. The implementation of safe methods for delivering light to the retina requires a better understanding of the mechanism causing autofluorescence reduction. Finally, RPE imaging was demonstrated using light levels that do not cause a detectable reduction in autofluorescence.

  4. Quantitative method to assess caries via fluorescence imaging from the perspective of autofluorescence spectral analysis

    International Nuclear Information System (INIS)

    Chen, Q G; Xu, Y; Zhu, H H; Chen, H; Lin, B

    2015-01-01

    A quantitative method to discriminate caries lesions for a fluorescence imaging system is proposed in this paper. The autofluorescence spectral investigation of 39 teeth samples classified by the International Caries Detection and Assessment System levels was performed at 405 nm excitation. The major differences in the different caries lesions focused on the relative spectral intensity range of 565–750 nm. The spectral parameter, defined as the ratio of wavebands at 565–750 nm to the whole spectral range, was calculated. The image component ratio R/(G + B) of color components was statistically computed by considering the spectral parameters (e.g. autofluorescence, optical filter, and spectral sensitivity) in our fluorescence color imaging system. Results showed that the spectral parameter and image component ratio presented a linear relation. Therefore, the image component ratio was graded as <0.66, 0.66–1.06, 1.06–1.62, and >1.62 to quantitatively classify sound, early decay, established decay, and severe decay tissues, respectively. Finally, the fluorescence images of caries were experimentally obtained, and the corresponding image component ratio distribution was compared with the classification result. A method to determine the numerical grades of caries using a fluorescence imaging system was proposed. This method can be applied to similar imaging systems. (paper)

  5. Imaging of Neuronal Activity in Awake Mice by Measurements of Flavoprotein Autofluorescence Corrected for Cerebral Blood Flow

    Directory of Open Access Journals (Sweden)

    Manami Takahashi

    2018-01-01

    Full Text Available Green fluorescence imaging (e.g., flavoprotein autofluorescence imaging, FAI can be used to measure neuronal activity and oxygen metabolism in living brains without expressing fluorescence proteins. It is useful for understanding the mechanism of various brain functions and their abnormalities in age-related brain diseases. However, hemoglobin in cerebral blood vessels absorbs green fluorescence, hampering accurate assessments of brain function in animal models with cerebral blood vessel dysfunctions and subsequent cerebral blood flow (CBF alterations. In the present study, we developed a new method to correct FAI signals for hemoglobin-dependent green fluorescence reductions by simultaneous measurements of green fluorescence and intrinsic optical signals. Intrinsic optical imaging enabled evaluations of light absorption and scatters by hemoglobin, which could then be applied to corrections of green fluorescence intensities. Using this method, enhanced flavoprotein autofluorescence by sensory stimuli was successfully detected in the brains of awake mice, despite increases of CBF, and hemoglobin interference. Moreover, flavoprotein autofluorescence could be properly quantified in a resting state and during sensory stimulation by a CO2 inhalation challenge, which modified vascular responses without overtly affecting neuronal activities. The flavoprotein autofluorescence signal data obtained here were in good agreement with the previous findings from a condition with drug-induced blockade of cerebral vasodilation, justifying the current assaying methodology. Application of this technology to studies on animal models of brain diseases with possible changes of CBF, including age-related neurological disorders, would provide better understanding of the mechanisms of neurovascular coupling in pathological circumstances.

  6. A simple protocol for attenuating the auto-fluorescence of cyanobacteria for optimized fluorescence in situ hybridization (FISH) imaging.

    Science.gov (United States)

    Zeller, Perrine; Ploux, Olivier; Méjean, Annick

    2016-03-01

    Cyanobacteria contain pigments, which generate auto-fluorescence that interferes with fluorescence in situ hybridization (FISH) imaging of cyanobacteria. We describe simple chemical treatments using CuSO4 or H2O2 that significantly reduce the auto-fluorescence of Microcystis strains. These protocols were successfully applied in FISH experiments using 16S rRNA specific probes and filamentous cyanobacteria. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Quantitative fundus autofluorescence in recessive Stargardt disease.

    Science.gov (United States)

    Burke, Tomas R; Duncker, Tobias; Woods, Russell L; Greenberg, Jonathan P; Zernant, Jana; Tsang, Stephen H; Smith, R Theodore; Allikmets, Rando; Sparrow, Janet R; Delori, François C

    2014-05-01

    To quantify fundus autofluorescence (qAF) in patients with recessive Stargardt disease (STGD1). A total of 42 STGD1 patients (ages: 7-52 years) with at least one confirmed disease-associated ABCA4 mutation were studied. Fundus AF images (488-nm excitation) were acquired with a confocal scanning laser ophthalmoscope equipped with an internal fluorescent reference to account for variable laser power and detector sensitivity. The gray levels (GLs) of each image were calibrated to the reference, zero GL, magnification, and normative optical media density to yield qAF. Texture factor (TF) was calculated to characterize inhomogeneities in the AF image and patients were assigned to the phenotypes of Fishman I through III. Quantified fundus autofluorescence in 36 of 42 patients and TF in 27 of 42 patients were above normal limits for age. Young patients exhibited the relatively highest qAF, with levels up to 8-fold higher than healthy eyes. Quantified fundus autofluorescence and TF were higher in Fishman II and III than Fishman I, who had higher qAF and TF than healthy eyes. Patients carrying the G1916E mutation had lower qAF and TF than most other patients, even in the presence of a second allele associated with severe disease. Quantified fundus autofluorescence is an indirect approach to measuring RPE lipofuscin in vivo. We report that ABCA4 mutations cause significantly elevated qAF, consistent with previous reports indicating that increased RPE lipofuscin is a hallmark of STGD1. Even when qualitative differences in fundus AF images are not evident, qAF can elucidate phenotypic variation. Quantified fundus autofluorescence will serve to establish genotype-phenotype correlations and as an outcome measure in clinical trials.

  8. Quantitative Fundus Autofluorescence in Recessive Stargardt Disease

    Science.gov (United States)

    Burke, Tomas R.; Duncker, Tobias; Woods, Russell L.; Greenberg, Jonathan P.; Zernant, Jana; Tsang, Stephen H.; Smith, R. Theodore; Allikmets, Rando; Sparrow, Janet R.; Delori, François C.

    2014-01-01

    Purpose. To quantify fundus autofluorescence (qAF) in patients with recessive Stargardt disease (STGD1). Methods. A total of 42 STGD1 patients (ages: 7–52 years) with at least one confirmed disease-associated ABCA4 mutation were studied. Fundus AF images (488-nm excitation) were acquired with a confocal scanning laser ophthalmoscope equipped with an internal fluorescent reference to account for variable laser power and detector sensitivity. The gray levels (GLs) of each image were calibrated to the reference, zero GL, magnification, and normative optical media density to yield qAF. Texture factor (TF) was calculated to characterize inhomogeneities in the AF image and patients were assigned to the phenotypes of Fishman I through III. Results. Quantified fundus autofluorescence in 36 of 42 patients and TF in 27 of 42 patients were above normal limits for age. Young patients exhibited the relatively highest qAF, with levels up to 8-fold higher than healthy eyes. Quantified fundus autofluorescence and TF were higher in Fishman II and III than Fishman I, who had higher qAF and TF than healthy eyes. Patients carrying the G1916E mutation had lower qAF and TF than most other patients, even in the presence of a second allele associated with severe disease. Conclusions. Quantified fundus autofluorescence is an indirect approach to measuring RPE lipofuscin in vivo. We report that ABCA4 mutations cause significantly elevated qAF, consistent with previous reports indicating that increased RPE lipofuscin is a hallmark of STGD1. Even when qualitative differences in fundus AF images are not evident, qAF can elucidate phenotypic variation. Quantified fundus autofluorescence will serve to establish genotype-phenotype correlations and as an outcome measure in clinical trials. PMID:24677105

  9. DISCORDANCE BETWEEN BLUE-LIGHT AUTOFLUORESCENCE AND NEAR-INFRARED AUTOFLUORESCENCE IN AGE-RELATED MACULAR DEGENERATION.

    Science.gov (United States)

    Heiferman, Michael J; Fawzi, Amani A

    2016-12-01

    To identify the origin and significance of discordance between blue-light autofluorescence (BL-AF; 488 nm) and near-infrared autofluorescence (NI-AF; 787 nm) in patients with age-related macular degeneration (AMD). A total of 86 eyes of 59 patients with a diagnosis of AMD were included in this cross-sectional study conducted between March 9, 2015 and May 1, 2015. A masked observer examined the BL-AF, NI-AF, and spectral-domain optical coherence tomography images. Areas with discordance of autofluorescence patterns between NI-AF and BL-AF images were correlated with structural findings at the corresponding location in optical coherence tomography scans. Seventy-nine eyes had discordance between BL-AF and NI-AF. The most common optical coherence tomography finding accounting for these discrepancies was pigment migration accounting for 35 lesions in 21 eyes. The most clinically relevant finding was geographic atrophy missed on BL-AF in 7 eyes. Our findings indicate that variations in the distribution of lipofuscin, melanin and melanolipofuscin account for the majority of discordance between BL-AF and NI-AF. Given our finding of missed geographic atrophy lesions on BL-AF in 24% of eyes with geographic atrophy (7/29 eyes), clinicians should consider multimodal imaging, including NI-AF and optical coherence tomography, especially in clinical trials of geographic atrophy.

  10. Fundus Autofluorescence Imaging in an Ocular Screening Program

    Directory of Open Access Journals (Sweden)

    A. M. Kolomeyer

    2012-01-01

    Full Text Available Purpose. To describe integration of fundus autofluorescence (FAF imaging into an ocular screening program. Methods. Fifty consecutive screening participants were included in this prospective pilot imaging study. Color and FAF (530/640 nm exciter/barrier filters images were obtained with a 15.1MP Canon nonmydriatic hybrid camera. A clinician evaluated the images on site to determine need for referral. Visual acuity (VA, intraocular pressure (IOP, and ocular pathology detected by color fundus and FAF imaging modalities were recorded. Results. Mean ± SD age was 47.4 ± 17.3 years. Fifty-two percent were female and 58% African American. Twenty-seven percent had a comprehensive ocular examination within the past year. Mean VA was 20/39 in the right eye and 20/40 in the left eye. Mean IOP was 15 mmHg bilaterally. Positive color and/or FAF findings were identified in nine (18% individuals with diabetic retinopathy or macular edema (n=4, focal RPE defects (n=2, age-related macular degeneration (n=1, central serous retinopathy (n=1, and ocular trauma (n=1. Conclusions. FAF was successfully integrated in our ocular screening program and aided in the identification of ocular pathology. Larger studies examining the utility of this technology in screening programs may be warranted.

  11. Fundus autofluorescence imaging in an ocular screening program.

    Science.gov (United States)

    Kolomeyer, A M; Nayak, N V; Szirth, B C; Khouri, A S

    2012-01-01

    Purpose. To describe integration of fundus autofluorescence (FAF) imaging into an ocular screening program. Methods. Fifty consecutive screening participants were included in this prospective pilot imaging study. Color and FAF (530/640 nm exciter/barrier filters) images were obtained with a 15.1MP Canon nonmydriatic hybrid camera. A clinician evaluated the images on site to determine need for referral. Visual acuity (VA), intraocular pressure (IOP), and ocular pathology detected by color fundus and FAF imaging modalities were recorded. Results. Mean ± SD age was 47.4 ± 17.3 years. Fifty-two percent were female and 58% African American. Twenty-seven percent had a comprehensive ocular examination within the past year. Mean VA was 20/39 in the right eye and 20/40 in the left eye. Mean IOP was 15 mmHg bilaterally. Positive color and/or FAF findings were identified in nine (18%) individuals with diabetic retinopathy or macular edema (n = 4), focal RPE defects (n = 2), age-related macular degeneration (n = 1), central serous retinopathy (n = 1), and ocular trauma (n = 1). Conclusions. FAF was successfully integrated in our ocular screening program and aided in the identification of ocular pathology. Larger studies examining the utility of this technology in screening programs may be warranted.

  12. Simultaneous in vivo imaging of melanin and lipofuscin in the retina with photoacoustic ophthalmoscopy and autofluorescence imaging

    Science.gov (United States)

    Zhang, Xiangyang; Zhang, Hao F.; Puliafito, Carmen A.; Jiao, Shuliang

    2011-08-01

    We combined photoacoustic ophthalmoscopy (PAOM) with autofluorescence imaging for simultaneous in vivo imaging of dual molecular contrasts in the retina using a single light source. The dual molecular contrasts come from melanin and lipofuscin in the retinal pigment epithelium (RPE). Melanin and lipofuscin are two types of pigments and are believed to play opposite roles (protective versus exacerbate) in the RPE in the aging process. We have successfully imaged the retina of pigmented and albino rats at different ages. The experimental results showed that multimodal PAOM system can be a potentially powerful tool in the study of age-related degenerative retinal diseases.

  13. Integrated biophotonics in endoscopic oncology

    Science.gov (United States)

    Muguruma, Naoki; DaCosta, Ralph S.; Wilson, Brian C.; Marcon, Norman E.

    2009-02-01

    Gastrointestinal endoscopy has made great progress during last decade. Diagnostic accuracy can be enhanced by better training, improved dye-contrast techniques method, and the development of new image processing technologies. However, diagnosis using conventional endoscopy with white-light optical imaging is essentially limited by being based on morphological changes and/or visual attribution: hue, saturation and intensity, interpretation of which depends on the endoscopist's eye and brain. In microlesions in the gastrointestinal tract, we still rely ultimately on the histopathological diagnosis from biopsy specimens. Autofluorescence imaging system has been applied for lesions which have been difficult to morphologically recognize or are indistinct with conventional endoscope, and this approach has potential application for the diagnosis of dysplastic lesions and early cancers in the gastrointestinal tract, supplementing the information from white light endoscopy. This system has an advantage that it needs no administration of a photosensitive agent, making it suitable as a screening method for the early detection of neoplastic tissues. Narrow band imaging (NBI) is a novel endoscopic technique which can distinguish neoplastic and non-neoplastic lesions without chromoendoscopy. Magnifying endoscopy in combination with NBI has an obvious advantage, namely analysis of the epithelial pit pattern and the vascular network. This new technique allows a detailed visualization in early neoplastic lesions of esophagus, stomach and colon. However, problems remain; how to combine these technologies in an optimum diagnostic strategy, how to apply them into the algorithm for therapeutic decision-making, and how to standardize several classifications surrounding them. 'Molecular imaging' is a concept representing the most novel imaging methods in medicine, although the definition of the word is still controversial. In the field of gastrointestinal endoscopy, the future of

  14. [Fundus autofluorescence in dry AMD - impact on disease progression].

    Science.gov (United States)

    Vidinova, C N; Gouguchkova, P T; Vidinov, K N

    2013-11-01

    Fundus autofluorescence is a novel technique that gives us information about the RPE cells by evaluating the distribution of lipofuscin in the retina. The purpose of our study was to evaluate the diagnostic abilities of OCT, RTVue and fundus autofluorescence in predicting the progression of dry AMD. In our study 37 dry AMD patients were enrolled: 22 of them with druses and 15 with developed geographic atrophy. They all underwent complete ophthalmological examinations including OCT and autofluorescence. We used the RTVue OCT programmes HD line, Cross line, EMM5 and EMM5 progression in all cases. The autofluorescence was recorded with the help of the Canon CX1 fundus camera. OCT images in the AMD patients with dry AMD and large druses showed typical undulations in the RPE/choroid line and occasionally drusenoid detachment of the RPE. Autofluorescence showed different patterns. The confluent reticular autofluorescence was associated with the development of neovascular membranes. In geographic atrophy patient OCTs showed diminished retinal thickness measured with EMM5. On autofluorescence the findings at the border zone atrophic/normal retina were of particular importance. The diffuse increased autofluorescence in that area was considered to be a sign for further atrophy progression. Our results point out that OCT in combination with autofluorescence is important in following the progression of dry AMD. Pathological autofluorescence at the border of atrophic lesions is an important sign for disease activity. Although both OCT and autofluorescence visualise the changes in RPE, autofluorescence is of key importance in predicting the development of the disease. Georg Thieme Verlag KG Stuttgart · New York.

  15. A simple viability analysis for unicellular cyanobacteria using a new autofluorescence assay, automated microscopy, and ImageJ

    Directory of Open Access Journals (Sweden)

    Schulze Katja

    2011-11-01

    Full Text Available Abstract Background Currently established methods to identify viable and non-viable cells of cyanobacteria are either time-consuming (eg. plating or preparation-intensive (eg. fluorescent staining. In this paper we present a new and fast viability assay for unicellular cyanobacteria, which uses red chlorophyll fluorescence and an unspecific green autofluorescence for the differentiation of viable and non-viable cells without the need of sample preparation. Results The viability assay for unicellular cyanobacteria using red and green autofluorescence was established and validated for the model organism Synechocystis sp. PCC 6803. Both autofluorescence signals could be observed simultaneously allowing a direct classification of viable and non-viable cells. The results were confirmed by plating/colony count, absorption spectra and chlorophyll measurements. The use of an automated fluorescence microscope and a novel ImageJ based image analysis plugin allow a semi-automated analysis. Conclusions The new method simplifies the process of viability analysis and allows a quick and accurate analysis. Furthermore results indicate that a combination of the new assay with absorption spectra or chlorophyll concentration measurements allows the estimation of the vitality of cells.

  16. Image acquisition in laparoscopic and endoscopic surgery

    Science.gov (United States)

    Gill, Brijesh S.; Georgeson, Keith E.; Hardin, William D., Jr.

    1995-04-01

    Laparoscopic and endoscopic surgery rely uniquely on high quality display of acquired images, but a multitude of problems plague the researcher who attempts to reproduce such images for educational purposes. Some of these are intrinsic limitations of current laparoscopic/endoscopic visualization systems, while others are artifacts solely of the process used to acquire and reproduce such images. Whatever the genesis of these problems, a glance at current literature will reveal the extent to which endoscopy suffers from an inability to reproduce what the surgeon sees during a procedure. The major intrinsic limitation to the acquisition of high-quality still images from laparoscopic procedures lies in the inability to couple directly a camera to the laparoscope. While many systems have this capability, this is useful mostly for otolaryngologists, who do not maintain a sterile field around their scopes. For procedures in which a sterile field must be maintained, one trial method has been to use a beam splitter to send light both to the still camera and the digital video camera. This is no solution, however, since this results in low quality still images as well as a degradation of the image that the surgeon must use to operate, something no surgeon tolerates lightly. Researchers thus must currently rely on other methods for producing images from a laparoscopic procedure. Most manufacturers provide an optional slide or print maker that provides a hardcopy output from the processed composite video signal. The results achieved from such devices are marginal, to say the least. This leaves only one avenue for possible image production, the videotape record of an endoscopic or laparoscopic operation. Video frame grabbing is at least a problem to which industry has applied considerable time and effort to solving. Our own experience with computerized enhancement of videotape frames has been very promising. Computer enhancement allows the researcher to correct several of the

  17. Enhancing analysis of cells and proteins by fluorescence imaging on silk-based biomaterials: modulating the autofluorescence of silk.

    Science.gov (United States)

    Neo, Puay Yong; Tan, Daryl Jian-An; Shi, Pujiang; Toh, Siew Lok; Goh, James Cho-Hong

    2015-02-01

    Silk is a versatile and established biomaterial for various tissue engineering purposes. However, it also exhibits strong autofluorescence signals-thereby hindering fluorescence imaging analysis of cells and proteins on silk-derived biomaterials. Sudan Black B (SB) is a lysochrome dye commonly used to stain lipids in histology. It has also been reported to be able to quench autofluorescence of tissues in histology and has been tested on artificial biomedical polymers in recent years. It was hypothesized that SB would exert similar quenching effects on silk, modulating the autofluorescence signals, and thereby enabling improved imaging analysis of cells and molecules of interests. The quenching effect of SB on the intrinsic fluorescence properties of silk and on commercial fluorescent dyes were first investigated in this study. SB was then incorporated into typical fluorescence-based staining protocols to study its effectiveness in improving fluorescence-based imaging of the cells and proteins residing with the silk-based biomaterials. Silk processed into various forms of biomaterials (e.g., films, sponges, fibers, and electrospun mats) was seeded with cells and cultured in vitro. At sacrificial time points, specimens were harvested, fixed, and prepared for fluorescence staining. SB, available commercially as a powder, was dissolved in 70% ethanol (0.3% [w/v]) to form staining solutions. SB treatment was introduced at the last step of typical immunofluorescence staining protocols for 15-120 min. For actin staining protocols by phalloidin toxin, SB staining solutions were added before and after permeabilization with Triton-X for 15-30 min. Results showed that ideal SB treatment duration is about 15 min. Apart from being able to suppress the autofluorescence of silk, this treatment duration was also not too long to adversely affect the fluorescent labeling probes used. The relative improvement brought about by SB treatment was most evident in the blue and green

  18. [Fundus autofluorescence. Has it a place in the management of diabetic macular edema?

    Science.gov (United States)

    Zbiba, W; Baba, A; Bouayed, E; Daldoul, A

    2016-11-01

    Analyze the characteristics of fundus autofluorescence of diabetic macular edema and study the association between these characteristics and visual function. Our study included 18 patients (28 eyes) with clinically significant diabetic macular edema. All patients had a complete eye examination with a fundus autofluorescence imaging and optical coherence tomography. The central macular thickness and central macular volume were measured. The integrity of the inner segment-outer segment junction and the integrity of the external limiting membrane were also evaluated in the same area. Among the 28 eyes studied, 8 had normal autofluorescence. The remaining 20 eyes had abnormal autofluorescence: a hyper-cystoid autofluorescence in 5 eyes (25%), hyper-spot autofluorescence in 8 eyes (40%), and hypo-irregular autofluorescence in 5 eyes (25%). Best corrected visual acuity was significantly better in patients with normal autofluorescence and those with hyper-cystoid autofluorescence. There was no significant difference in central macular thickness (P=0.186) and central macular volume (P=0.191) between the four groups. The autofluorescence is a simple, fast, and non-invasive technique for the study of diabetic macular edema with good correlation to the visual function as well as to the extent of damage to the retina. It is, therefore, a possible alternative to other invasive imaging techniques in particular in the long term monitoring of diabetic macular edema. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  19. Design of a modified endoscope illuminator for spectral imaging of colorectal tissues

    Science.gov (United States)

    Browning, Craig M.; Mayes, Samuel; Rich, Thomas C.; Leavesley, Silas J.

    2017-02-01

    The gold standard for locating colonic polyps is a white light endoscope in a colonoscopy, however, polyps smaller than 5 mm can be easily missed. Modified procedures such as narrow band imaging have shown only marginal increases in detection rates. Spectral imaging is a potential solution to improve the sensitivity and specificity of colonoscopies by providing the ability to distinguish molecular fluorescence differences in tissues. The goal of this work is to implement a spectral endoscopic light source to acquire spectral image data of colorectal tissues. A beta-version endoscope light source was developed, by retrofitting a white light endoscope light source (Olympus, CLK-4) with 16 narrow band LEDs. This redesigned, beta-prototype uses high-power LEDs with a minimum output of 500 mW to provide sufficient spectral output (0.5 mW) through the endoscope. A mounting apparatus was designed to provide sufficient heat dissipation. Here, we report recent results of our tests to characterize the intensity output through the light source and endoscope to determine the flat spectral output for imaging and intensity losses through the endoscope. We also report preliminary spectral imaging data from transverse pig colon that demonstrates the ability to result in working practical spectral data. Preliminary results of this revised prototype spectral endoscope system demonstrate that there is sufficient power to allow the imaging process to continue and potentially determine spectral differences in cancerous and normal tissue from imaging ex vivo pairs. Future work will focus on building a spectral library for the colorectal region and refining the user interface the system for in vivo use.

  20. Correcting the Chromatic Aberration in Barrel Distortion of Endoscopic Images

    Directory of Open Access Journals (Sweden)

    Y. M. Harry Ng

    2003-04-01

    Full Text Available Modern endoscopes offer physicians a wide-angle field of view (FOV for minimally invasive therapies. However, the high level of barrel distortion may prevent accurate perception of image. Fortunately, this kind of distortion may be corrected by digital image processing. In this paper we investigate the chromatic aberrations in the barrel distortion of endoscopic images. In the past, chromatic aberration in endoscopes is corrected by achromatic lenses or active lens control. In contrast, we take a computational approach by modifying the concept of image warping and the existing barrel distortion correction algorithm to tackle the chromatic aberration problem. In addition, an error function for the determination of the level of centroid coincidence is proposed. Simulation and experimental results confirm the effectiveness of our method.

  1. Three-dimensional photoacoustic endoscopic imaging of the rabbit esophagus.

    Science.gov (United States)

    Yang, Joon Mo; Favazza, Christopher; Yao, Junjie; Chen, Ruimin; Zhou, Qifa; Shung, K Kirk; Wang, Lihong V

    2015-01-01

    We report photoacoustic and ultrasonic endoscopic images of two intact rabbit esophagi. To investigate the esophageal lumen structure and microvasculature, we performed in vivo and ex vivo imaging studies using a 3.8-mm diameter photoacoustic endoscope and correlated the images with histology. Several interesting anatomic structures were newly found in both the in vivo and ex vivo images, which demonstrates the potential clinical utility of this endoscopic imaging modality. In the ex vivo imaging experiment, we acquired high-resolution motion-artifact-free three-dimensional photoacoustic images of the vasculatures distributed in the walls of the esophagi and extending to the neighboring mediastinal regions. Blood vessels with apparent diameters as small as 190 μm were resolved. Moreover, by taking advantage of the dual-mode high-resolution photoacoustic and ultrasound endoscopy, we could better identify and characterize the anatomic structures of the esophageal lumen, such as the mucosal and submucosal layers in the esophageal wall, and an esophageal branch of the thoracic aorta. In this paper, we present the first photoacoustic images showing the vasculature of a vertebrate esophagus and discuss the potential clinical applications and future development of photoacoustic endoscopy.

  2. Three-dimensional photoacoustic endoscopic imaging of the rabbit esophagus.

    Directory of Open Access Journals (Sweden)

    Joon Mo Yang

    Full Text Available We report photoacoustic and ultrasonic endoscopic images of two intact rabbit esophagi. To investigate the esophageal lumen structure and microvasculature, we performed in vivo and ex vivo imaging studies using a 3.8-mm diameter photoacoustic endoscope and correlated the images with histology. Several interesting anatomic structures were newly found in both the in vivo and ex vivo images, which demonstrates the potential clinical utility of this endoscopic imaging modality. In the ex vivo imaging experiment, we acquired high-resolution motion-artifact-free three-dimensional photoacoustic images of the vasculatures distributed in the walls of the esophagi and extending to the neighboring mediastinal regions. Blood vessels with apparent diameters as small as 190 μm were resolved. Moreover, by taking advantage of the dual-mode high-resolution photoacoustic and ultrasound endoscopy, we could better identify and characterize the anatomic structures of the esophageal lumen, such as the mucosal and submucosal layers in the esophageal wall, and an esophageal branch of the thoracic aorta. In this paper, we present the first photoacoustic images showing the vasculature of a vertebrate esophagus and discuss the potential clinical applications and future development of photoacoustic endoscopy.

  3. Terahertz endoscopic imaging for colorectal cancer detection: Current status and future perspectives.

    Science.gov (United States)

    Doradla, Pallavi; Joseph, Cecil; Giles, Robert H

    2017-08-16

    Terahertz (THz) imaging is progressing as a robust platform for myriad applications in the field of security, health, and material science. The THz regime, which comprises wavelengths spanning from microns to millimeters, is non-ionizing and has very low photon energy: Making it inherently safe for biological imaging. Colorectal cancer is one of the most common causes of death in the world, while the conventional screening and standard of care yet relies exclusively on the physician's experience. Researchers have been working on the development of a flexible THz endoscope, as a potential tool to aid in colorectal cancer screening. This involves building a single-channel THz endoscope, and profiling the THz response from colorectal tissue, and demonstrating endogenous contrast levels between normal and diseased tissue when imaging in reflection modality. The current level of contrast provided by the prototype THz endoscopic system represents a significant step towards clinical endoscopic application of THz technology for in-vivo colorectal cancer screening. The aim of this paper is to provide a short review of the recent advances in THz endoscopic technology and cancer imaging. In particular, the potential of single-channel THz endoscopic imaging for colonic cancer screening will be highlighted.

  4. Spectral autofluorescence imaging of the retina for drusen detection

    Science.gov (United States)

    Foubister, James J.; Gorman, Alistair; Harvey, Andy; Hemert, Jano van

    2018-02-01

    The presence and characteristics of drusen in retinal images, namely their size, location, and distribution, can be used to aid in the diagnosis and monitoring of Age Related Macular Degeneration (AMD); one of the leading causes for blindness in the elderly population. Current imaging techniques are effective at determining the presence and number of drusen, but fail when it comes to classifying their size and form. These distinctions are important for correctly characterising the disease, especially in the early stages where the development of just one larger drusen can indicate progression. Another challenge for automated detection is in distinguishing them from other retinal features, such as cotton wool spots. We describe the development of a multi-spectral scanning-laser ophthalmoscope that records images of retinal autofluorescence (AF) in four spectral bands. This will offer the potential to detect drusen with improved contrast based on spectral discrimination for automated classification. The resulting improved specificity and sensitivity for their detection offers more reliable characterisation of AMD. We present proof of principle images prior to further system optimisation and clinical trials for assessment of enhanced detection of drusen.

  5. Portable LED-induced autofluorescence imager with a probe of L shape for oral cancer diagnosis

    Science.gov (United States)

    Huang, Ting-Wei; Lee, Yu-Cheng; Cheng, Nai-Lun; Yan, Yung-Jhe; Chiang, Hou-Chi; Chiou, Jin-Chern; Mang, Ou-Yang

    2015-08-01

    The difference of spectral distribution between lesions of epithelial cells and normal cells after excited fluorescence is one of methods for the cancer diagnosis. In our previous work, we developed a portable LED Induced autofluorescence (LIAF) imager contained the multiple wavelength of LED excitation light and multiple filters to capture ex-vivo oral tissue autofluorescence images. Our portable system for detection of oral cancer has a probe in front of the lens for fixing the object distance. The shape of the probe is cone, and it is not convenient for doctor to capture the oral image under an appropriate view angle in front of the probe. Therefore, a probe of L shape containing a mirror is proposed for doctors to capture the images with the right angles, and the subjects do not need to open their mouse constrainedly. Besides, a glass plate is placed in probe to prevent the liquid entering in the body, but the light reflected from the glass plate directly causes the light spots inside the images. We set the glass plate in front of LED to avoiding the light spots. When the distance between the glasses plate and the LED model plane is less than the critical value, then we can prevent the light spots caused from the glasses plate. The experiments show that the image captured with the new probe that the glasses plate placed in the back-end of the probe has no light spots inside the image.

  6. Autofluorescence guided diagnostic evaluation of suspicious oral mucosal lesions: opportunities, limitations, and pitfalls

    Science.gov (United States)

    Vigneswaran, Nadarajah

    2011-03-01

    Wide-filed autofluorescence examination is currently considered as a standard of care for screening and diagnostic evaluation of early neoplastic changes of the skin, cervix, lung, bladder, gastrointestinal tract and oral cavity. Naturally occurring fluorophores within the tissue absorb UV and visible light and can re-emit some of this light at longer wavelengths in the form of fluorescence. This non-invasive tissue autofluorescence imaging is used in optical diagnostics, especially in the early detection of cancer. Usually, malignant transformation is associated with thickening of the epithelium, enhanced cellular density due to increased nuclear cytoplasmic ratio which may attenuate the excitation leading to a decrease in collagen autofluorescence. Hence, dysplastic and cancerous tissues often exhibit decreased blue-green autofluorescence and appear darker compared to uninvolved mucosa. Currently, there are three commercially available devices to examine tissue autofluorescence in the oral cavity. In this study we used the oral cancer screening device IdentafiTM 3000 to examine the tissue reflectance and autofluorescence of PML and confounding lesions of the oral cavity. Wide-field autofluorescence imaging enables rapid inspection of large mucosal surfaces, to aid in recognition of suspicious lesions and may also help in discriminate the PML (class 1) from some of the confounding lesions (class II). However, the presence of inflammation or pigments is also associated with loss of stromal autofluorescence, and may give rise to false-positive results with widefield fluorescence imaging. Clinicians who use these autofluorescence based oral cancer screening devices should be aware about the benign oral mucosal lesions that may give false positivity so that unnecessary patient's anxiety and the need for scalpel biopsy can be eliminated.

  7. HYPERSPECTRAL AUTOFLUORESCENCE IMAGING OF DRUSEN AND RETINAL PIGMENT EPITHELIUM IN DONOR EYES WITH AGE-RELATED MACULAR DEGENERATION.

    Science.gov (United States)

    Tong, Yuehong; Ben Ami, Tal; Hong, Sungmin; Heintzmann, Rainer; Gerig, Guido; Ablonczy, Zsolt; Curcio, Christine A; Ach, Thomas; Smith, R Theodore

    2016-12-01

    To elucidate the molecular pathogenesis of age-related macular degeneration (AMD) and interpretation of fundus autofluorescence imaging, the authors identified spectral autofluorescence characteristics of drusen and retinal pigment epithelium (RPE) in donor eyes with AMD. Macular RPE/Bruch membrane flat mounts were prepared from 5 donor eyes with AMD. In 12 locations (1-3 per eye), hyperspectral autofluorescence images in 10-nm-wavelength steps were acquired at 2 excitation wavelengths (λex 436, 480 nm). A nonnegative tensor factorization algorithm was used to recover 5 abundant emission spectra and their corresponding spatial localizations. At λex 436 nm, the authors consistently localized a novel spectrum (SDr) with a peak emission near 510 nm in drusen and sub-RPE deposits. Abundant emission spectra seen previously (S0 in Bruch membrane and S1, S2, and S3 in RPE lipofuscin/melanolipofuscin, respectively) also appeared in AMD eyes, with the same shapes and peak wavelengths as in normal tissue. Lipofuscin/melanolipofuscin spectra localizations in AMD eyes varied widely in their overlap with drusen, ranging from none to complete. An emission spectrum peaking at ∼510 nm (λex 436 nm) appears to be sensitive and specific for drusen and sub-RPE deposits. One or more abundant spectra from RPE organelles exhibit characteristic relationships with drusen.

  8. UTILIZATION OF FUNDUS AUTOFLUORESCENCE, SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY, AND ENHANCED DEPTH IMAGING IN THE CHARACTERIZATION OF BIETTI CRYSTALLINE DYSTROPHY IN DIFFERENT STAGES.

    Science.gov (United States)

    Li, Qian; Li, Yang; Zhang, Xiaohui; Xu, Zhangxing; Zhu, Xiaoqing; Ma, Kai; She, Haicheng; Peng, Xiaoyan

    2015-10-01

    To characterize Bietti crystalline dystrophy (BCD) in different stages using multiple imaging modalities. Sixteen participants clinically diagnosed as BCD were included in the retrospective study and were categorized into 3 stages according to fundus photography. Eleven patients were genetically confirmed. Fundus autofluorescence, spectral domain optical coherence tomography, and enhanced depth imaging features of BCD were analyzed. On fundus autofluorescence, the abnormal autofluorescence was shown to enlarge in area and decrease in intensity with stages. Using spectral domain optical coherence tomography, the abnormalities in Stage 1 were observed to localize in outer retinal layers, whereas in Stage 2 and Stage 3, more extensive retinal atrophy was seen. In enhanced depth imaging, the subfoveal choroidal layers were delineated clearly in Stage 1; in Stage 2, destructions were primarily found in the choriocapillaris with associated alterations in the outer vessels; Stage 3 BCD displayed severe choroidal thinning. Choroidal neovascularization and macular edema were exhibited with high incidence. IVS6-8del17bp/inGC of the CYP4V2 gene was the most common mutant allele. Noninvasive fundus autofluorescence, spectral domain optical coherence tomography, and enhanced depth imaging may help to characterize the chorioretinal pathology of BCD at different degrees, and therefore, we propose staging of BCD depending on those methods. Physicians should be cautious of the vision-threatening complications of the disease.

  9. Two-photon autofluorescence/FLIM/SHG endoscopy to study the oral cavity and wound healing in humans (Conference Presentation)

    Science.gov (United States)

    König, Karsten

    2016-03-01

    Monitoring the oral cavity noninvasively with superior 3D resolution is realized by clinical multiphoton tomography and high NA two-photon endoscopy without the need of additional contrast agents. The technology behind this investigation is based on nonlinear optical contrast of the multiphoton tomograph MPTflex®. Furthermore, the miniaturized GRIN endoscope was used to realize more accessibility for more demanding wound conditions in skin. The MPTflex® distinguishes autofluorescence (AF) signals from second harmonic generation (SHG) signals simultaneously. Fluorescence lifetime imaging (FLIM) based on time correlated single photon counting (TCSPC) technology offers additional information on the functional level of the intratissue fluorophores, their binding status, and the contribution of SHG signals in chronic wounds.

  10. A review of fundus autofluorescence imaging

    OpenAIRE

    D. J. Booysen

    2013-01-01

    Autofluorscence photography of the retina provides important diagnostic information about diseases that affect the outer retina; more specifically the retinal pigment epithelium and photoreceptors. Fundus autofluorescence can alsobe used to evaluate macular pigment density and other diseases of the retina and choroid. It is a non-invasive clinical tool which has the potential to revolutionise clinical retina practice. (S Afr Optom 2013 72(1) 46-53)

  11. Virtual endoscopic images by 3D FASE cisternography for neurovascular compression

    International Nuclear Information System (INIS)

    Ishimori, Takashi; Nakano, Satoru; Kagawa, Masahiro

    2003-01-01

    Three-dimensional fast asymmetric spin echo (3D FASE) cisternography provides high spatial resolution and excellent contrast as a water image acquisition technique. It is also useful for the evaluation of various anatomical regions. This study investigated the usefulness and limitations of virtual endoscopic images obtained by 3D FASE MR cisternography in the preoperative evaluation of patients with neurovascular compression. The study included 12 patients with neurovascular compression: 10 with hemifacial spasm and two with trigeminal neuralgia. The diagnosis was surgically confirmed in all patients. The virtual endoscopic images obtained were judged to be of acceptable quality for interpretation in all cases. The areas of compression identified in preoperative diagnosis with virtual endoscopic images showed good agreement with those observed from surgery, except in one case in which the common trunk of the anterior inferior cerebellar artery and posterior inferior cerebellar artery (AICA-PICA) bifurcated near the root exit zone of the facial nerve. The veins are displayed in some cases but not in others. The main advantage of generating virtual endoscopic images is that such images can be used for surgical simulation, allowing the neurosurgeon to perform surgical procedures with greater confidence. (author)

  12. Time-resolved autofluorescence imaging of human donor retina tissue from donors with significant extramacular drusen.

    Science.gov (United States)

    Schweitzer, Dietrich; Gaillard, Elizabeth R; Dillon, James; Mullins, Robert F; Russell, Stephen; Hoffmann, Birgit; Peters, Sven; Hammer, Martin; Biskup, Christoph

    2012-06-08

    Time and spectrally resolved measurements of autofluorescence have the potential to monitor metabolism at the cellular level. Fluorophores that emit with the same fluorescence intensity can be discriminated from each other by decay time of fluorescence intensity after pulsed excitation. We performed time-resolved autofluorescence measurements on fundus samples from a donor with significant extramacular drusen. Tissue sections from two human donors were prepared and imaged with a laser scanning microscope. The sample was excited with a titanium-sapphire laser, which was tuned to 860 nm, and frequency doubled by a BBO crystal to 430 nm. The repetition rate was 76 MHz and the pulse width was 170 femtoseconds (fs). The time-resolved autofluorescence was recorded simultaneously in 16 spectral channels (445-605 nm) and bi-exponentially fitted. RPE can be discriminated clearly from Bruch's membrane, drusen, and choroidal connective tissue by fluorescence lifetime. In RPE, bright fluorescence of lipofuscin could be detected with a maximum at 510 nm and extending beyond 600 nm. The lifetime was 385 ps. Different types of drusen were found. Most of them did not contain lipofuscin and exhibited a weak fluorescence, with a maximum at 470 nm. The lifetime was 1785 picoseconds (ps). Also, brightly emitting lesions, presumably representing basal laminar deposits, with fluorescence lifetimes longer than those recorded in RPE could be detected. The demonstrated differentiation of fluorescent structures by their fluorescence decay time is important for interpretation of in vivo measurements by the new fluorescence lifetime imaging (FLIM) ophthalmoscopy on healthy subjects as well as on patients.

  13. Centrifugal Expansion of Fundus Autofluorescence Patterns in Stargardt Disease Over Time

    Science.gov (United States)

    Cukras, Catherine A.; Wong, Wai T.; Caruso, Rafael; Cunningham, Denise; Zein, Wadih; Sieving, Paul

    2012-01-01

    Objective Changing lipofuscin and melanin content in RPE cells has been hypothesized to contribute to Stargardt disease pathogenesis. Longitudinal study of autofluorescence in Stargardt disease which reflect changing fluorophore compositions can reveal aspects of disease progression not previously evident. Method We examined the temporal-spatial patterns of fundus autofluorescence with excitation at both 488 nm (standard fundus autofluorescence, FAF) and 795nm (near infrared autofluorescence, NIA) in a longitudinal case series involving 8 eyes of 4 patients (range of follow-up = 11 to 57 months; mean = 39 months). Image processing was performed to analyze spatial and temporal cross-modality associations. Results Longitudinal FAF imaging of fleck lesions revealed hyperautofluorescent lesions that extended in a centrifugal direction from the fovea with time. Patterns of spread were non-random and followed a radial path that leaves behind a trail of diminishing autofluorescence. Longitudinal NIA imaging also demonstrated centrifugal lesion spread, but with fewer hyperautofluorescent lesions, suggestive of more transient hyperautofluorescence and more rapid decay at longer wavelengths. FAF and NIA abnormalities were spatially correlated to each other, and together reflect systematic progressions in fleck distribution and fluorophore composition occurring during the natural history of the disease. Conclusion Stargardt disease fleck lesions do not evolve randomly in location but instead follow consistent patterns of radial expansion and a systematic decay of autofluorescence that reflect changing lipofuscin and melanin compositions in RPE cells. These progressive foveal-to-peripheral changes are helpful in elucidating molecular and cellular mechanisms underlying Stargardt disease and may constitute potential outcome measures in clinical trials. PMID:21987580

  14. Fundus autofluorescence findings in a mouse model of retinal detachment.

    Science.gov (United States)

    Secondi, Roberta; Kong, Jian; Blonska, Anna M; Staurenghi, Giovanni; Sparrow, Janet R

    2012-08-07

    Fundus autofluorescence (fundus AF) changes were monitored in a mouse model of retinal detachment (RD). RD was induced by transscleral injection of hyaluronic acid (Healon) or sterile balanced salt solution (BSS) into the subretinal space of 4-5-day-old albino Abca4 null mutant and Abca4 wild-type mice. Images acquired by confocal scanning laser ophthalmoscopy (Spectralis HRA) were correlated with spectral domain optical coherence tomography (SD-OCT), infrared reflectance (IR), fluorescence spectroscopy, and histologic analysis. Results. In the area of detached retina, multiple hyperreflective spots in IR images corresponded to punctate areas of intense autofluorescence visible in fundus AF mode. The puncta exhibited changes in fluorescence intensity with time. SD-OCT disclosed undulations of the neural retina and hyperreflectivity of the photoreceptor layer that likely corresponded to histologically visible photoreceptor cell rosettes. Fluorescence emission spectra generated using flat-mounted retina, and 488 and 561 nm excitation, were similar to that of RPE lipofuscin. With increased excitation wavelength, the emission maximum shifted towards longer wavelengths, a characteristic typical of fundus autofluorescence. In detached retinas, hyper-autofluorescent spots appeared to originate from photoreceptor outer segments that were arranged within retinal folds and rosettes. Consistent with this interpretation is the finding that the autofluorescence was spectroscopically similar to the bisretinoids that constitute RPE lipofuscin. Under the conditions of a RD, abnormal autofluorescence may arise from excessive production of bisretinoid by impaired photoreceptor cells.

  15. Autofluorescence of pigmented skin lesions using a pulsed UV laser with synchronized detection: clinical results

    Science.gov (United States)

    Cheng, Haynes P. H.; Svenmarker, Pontus; Xie, Haiyan; Tidemand-Lichtenberg, Peter; Jensen, Ole B.; Bendsoe, Niels; Svanberg, Katarina; Petersen, Paul Michael; Pedersen, Christian; Andersson-Engels, Stefan; Andersen, Peter E.

    2010-04-01

    We report preliminary clinical results of autofluorescence imaging of malignant and benign skin lesions, using pulsed 355 nm laser excitation with synchronized detection. The novel synchronized detection system allows high signal-tonoise ratio to be achieved in the resulting autofluorescence signal, which may in turn produce high contrast images that improve diagnosis, even in the presence of ambient room light. The synchronized set-up utilizes a compact, diode pumped, pulsed UV laser at 355 nm which is coupled to a CCD camera and a liquid crystal tunable filter. The excitation and image capture is sampled at 5 kHz and the resulting autofluorescence is captured with the liquid crystal filter cycling through seven wavelengths between 420 nm and 580 nm. The clinical study targets pigmented skin lesions and evaluates the prospects of using autofluorescence as a possible means in differentiating malignant and benign skin tumors. Up to now, sixteen patients have participated in the clinical study. The autofluorescence images, averaged over the exposure time of one second, will be presented along with histopathological results. Initial survey of the images show good contrast and diagnostic results show promising agreement based on the histopathological results.

  16. A review of fundus autofluorescence imaging

    Directory of Open Access Journals (Sweden)

    D. J. Booysen

    2013-12-01

    Full Text Available Autofluorscence photography of the retina provides important diagnostic information about diseases that affect the outer retina; more specifically the retinal pigment epithelium and photoreceptors. Fundus autofluorescence can alsobe used to evaluate macular pigment density and other diseases of the retina and choroid. It is a non-invasive clinical tool which has the potential to revolutionise clinical retina practice. (S Afr Optom 2013 72(1 46-53

  17. Reevaluation of JPEG image compression to digitalized gastrointestinal endoscopic color images: a pilot study

    Science.gov (United States)

    Kim, Christopher Y.

    1999-05-01

    Endoscopic images p lay an important role in describing many gastrointestinal (GI) disorders. The field of radiology has been on the leading edge of creating, archiving and transmitting digital images. With the advent of digital videoendoscopy, endoscopists now have the ability to generate images for storage and transmission. X-rays can be compressed 30-40X without appreciable decline in quality. We reported results of a pilot study using JPEG compression of 24-bit color endoscopic images. For that study, the result indicated that adequate compression ratios vary according to the lesion and that images could be compressed to between 31- and 99-fold smaller than the original size without an appreciable decline in quality. The purpose of this study was to expand upon the methodology of the previous sty with an eye towards application for the WWW, a medium which would expand both clinical and educational purposes of color medical imags. The results indicate that endoscopists are able to tolerate very significant compression of endoscopic images without loss of clinical image quality. This finding suggests that even 1 MB color images can be compressed to well under 30KB, which is considered a maximal tolerable image size for downloading on the WWW.

  18. Immediate and long-term changes of fundus autofluorescence in continuous wave laser lesions of the retina.

    Science.gov (United States)

    Framme, Carsten; Roider, Johann

    2004-01-01

    To determine whether fundus autofluorescence imaging is able to show changes in retinal pigment epithelium (RPE) fluorescence after thermal laser photocoagulation. In vivo imaging of fundus autofluorescence was performed with a scanning laser ophthalmoscope. A laser with a wavelength of 488 nm was used for excitation of the tissue and autofluorescence was detected above 500 nm using a barrier filter. One hundred eight eyes of 87 patients who had had previous laser treatment were monitored. The appearance and size of the laser lesions were documented and correlated to the time of treatment. Immediate changes were observed prospectively in 13 eyes; long-term follow-up was studied retrospectively in 95 eyes. In all patients but one, autofluorescence was decreased in the area of laser lesions 1 hour after laser treatment. After 1 month, previously decreased autofluorescence in all lesions changed to significantly increased autofluorescence, which was stable up to 6 months after treatment. Mixed forms were present approximately 6 to 12 months after treatment, showing a central island of increased autofluorescence surrounded by a ring of decreased autofluorescence. After 1 to 2 years, lesions again changed to complete dark spots, enlarging later on. RPE destruction and subsequent proliferation after continuous wave laser photocoagulation can be visualized noninvasively by autofluorescence imaging. Immediate decreased autofluorescence may indicate acute damage of the RPE, subsequent increased autofluorescence seems to indicate proliferative behavior of the RPE, and final dark spots can indicate RPE atrophy secondary to a denaturation of neurosensory retinal tissue. Thus, autofluorescence can be used in the long-term monitoring of RPE changes after laser treatment. The enlargement of the laser atrophy zone demonstrates the potential risk of visual loss after central laser photocoagulation even years after treatment.

  19. Infrared autofluorescence, short-wave autofluorescence and spectral-domain optical coherence tomography of optic disk melanocytomas

    Directory of Open Access Journals (Sweden)

    Peng Zhang

    2016-05-01

    Full Text Available AIM: To investigate the findings of infrared fundus autofluorescence (IR-AF and spectral-domain optical coherence tomography (SD-OCT in eyes with optic disc melanocytoma (ODM. METHODS: IR-AF findings and those of other ophthalmologic imaging examinations, including short-wave autofluorescence (SW-AF, fluorescein angiography (FA, fundus color photography, and SD-OCT of 8 eyes of 8 consecutive cases with ODM were assessed. RESULTS: The ODMs in all cases (100% presented similar IR-AF, SW-AF, and FA findings. On IR-AF images, ODMs showed outstanding hyper-AF with well-defined outline. On SW-AF images, the area of ODMs presented as hypo-AF. FA images revealed the leaking retinal telangiectasia on the surface of the ODMs. On SD-OCT images in 8 cases (100%, the ODMs were sloped with highly reflective surface, which were disorganized retina and optic nerve layers. In 7 cases (87.5%, peripapillary choroids were involved. The melanocytomas of 8 cases (100% presented as optically empty spaces. Vitreous seeds were found in one case (12.5%. CONCLUSION: IR-AF imaging may provide a new modality to evaluate the pathologic features of ODMs, and together with SW-AF imaging, offers a new tool to study biological characteristics associated with ODMs. SD-OCT is a valuable tool in delimitating the tumor extension and providing morphological information about the adjacent retinal tissue.

  20. Analysing the Progression Rates of Macular Lesions with Autofluorescence Imaging Modes in Dry Age-Related Macular Degeneration

    Directory of Open Access Journals (Sweden)

    Kenan Olcay

    2015-12-01

    Full Text Available Objectives: In this study we aimed to compare the sensitivity of blue-light fundus autofluorescence (FAF and near-infrared autofluorescence (NI-AF imaging for determining the progression rates of macular lesions in dry age-related macular degeneration (AMD. Materials and Methods: The study was designed retrospectively and included patients diagnosed with intermediate and advanced stage dry AMD. Best corrected visual acuities and FAF and NI-AF images were recorded in 46 eyes of 33 patients. Lesion borders were drawn manually on the images using Heidelberg Eye Explorer software and lesion areas were calculated by using Microsoft Excel software. BCVA and lesion areas were compared with each other. Results: Patients’ mean follow-up time was 30.98±13.30 months. The lesion area progression rates were 0.85±0.93 mm2/y in FAF and 0.93±1.01 mm2/y in NI-AF, showing statistically significant correlation with each other (r=0.883; p<0.01. Both imaging methods are moderately correlated with visual acuity impairment (r=0.362; p<0.05 and r=0.311; p<0.05, respectively. In addition, larger lesions showed higher progression rates than smaller ones in both imaging methods. Conclusion: NI-AF imaging is as important and effective as FAF imaging for follow-up of dry AMD patients.

  1. Portable LED-induced autofluorescence spectroscopy for oral cancer diagnosis

    Science.gov (United States)

    Yan, Yung-Jhe; Huang, Ting-Wei; Cheng, Nai-Lun; Hsieh, Yao-Fang; Tsai, Ming-Hsui; Chiou, Jin-Chern; Duann, Jeng-Ren; Lin, Yung-Jiun; Yang, Chin-Siang; Ou-Yang, Mang

    2017-04-01

    Oral cancer is a serious and growing problem in many developing and developed countries. To improve the cancer screening procedure, we developed a portable light-emitting-diode (LED)-induced autofluorescence (LIAF) imager that contains two wavelength LED excitation light sources and multiple filters to capture ex vivo oral tissue autofluorescence images. Compared with conventional means of oral cancer diagnosis, the LIAF imager is a handier, faster, and more highly reliable solution. The compact design with a tiny probe allows clinicians to easily observe autofluorescence images of hidden areas located in concave deep oral cavities. The ex vivo trials conducted in Taiwan present the design and prototype of the portable LIAF imager used for analyzing 31 patients with 221 measurement points. Using the normalized factor of normal tissues under the excitation source with 365 nm of the central wavelength and without the bandpass filter, the results revealed that the sensitivity was larger than 84%, the specificity was not smaller than over 76%, the accuracy was about 80%, and the area under curve of the receiver operating characteristic (ROC) was achieved at about 87%, respectively. The fact shows the LIAF spectroscopy has the possibilities of ex vivo diagnosis and noninvasive examinations for oral cancer.

  2. Polarized near-infrared autofluorescence imaging combined with near-infrared diffuse reflectance imaging for improving colonic cancer detection.

    Science.gov (United States)

    Shao, Xiaozhuo; Zheng, Wei; Huang, Zhiwei

    2010-11-08

    We evaluate the diagnostic feasibility of the integrated polarized near-infrared (NIR) autofluorescence (AF) and NIR diffuse reflectance (DR) imaging technique developed for colonic cancer detection. A total of 48 paired colonic tissue specimens (normal vs. cancer) were measured using the integrated NIR DR (850-1100 nm) and NIR AF imaging at the 785 nm laser excitation. The results showed that NIR AF intensities of cancer tissues are significantly lower than those of normal tissues (ppolarization conditions gives a higher diagnostic accuracy (of ~92-94%) compared to non-polarized NIR AF imaging or NIR DR imaging. Further, the ratio imaging of NIR DR to NIR AF with polarization provides the best diagnostic accuracy (of ~96%) among the NIR AF and NIR DR imaging techniques. This work suggests that the integrated NIR AF/DR imaging under polarization condition has the potential to improve the early diagnosis and detection of malignant lesions in the colon.

  3. Crowdsourcing for reference correspondence generation in endoscopic images.

    Science.gov (United States)

    Maier-Hein, Lena; Mersmann, Sven; Kondermann, Daniel; Stock, Christian; Kenngott, Hannes Gotz; Sanchez, Alexandro; Wagner, Martin; Preukschas, Anas; Wekerle, Anna-Laura; Helfert, Stefanie; Bodenstedt, Sebastian; Speidel, Stefanie

    2014-01-01

    Computer-assisted minimally-invasive surgery (MIS) is often based on algorithms that require establishing correspondences between endoscopic images. However, reference annotations frequently required to train or validate a method are extremely difficult to obtain because they are typically made by a medical expert with very limited resources, and publicly available data sets are still far too small to capture the wide range of anatomical/scene variance. Crowdsourcing is a new trend that is based on outsourcing cognitive tasks to many anonymous untrained individuals from an online community. To our knowledge, this paper is the first to investigate the concept of crowdsourcing in the context of endoscopic video image annotation for computer-assisted MIS. According to our study on publicly available in vivo data with manual reference annotations, anonymous non-experts obtain a median annotation error of 2 px (n = 10,000). By applying cluster analysis to multiple annotations per correspondence, this error can be reduced to about 1 px, which is comparable to that obtained by medical experts (n = 500). We conclude that crowdsourcing is a viable method for generating high quality reference correspondences in endoscopic video images.

  4. Ultrahigh sensitivity endoscopic camera using a new CMOS image sensor: providing with clear images under low illumination in addition to fluorescent images.

    Science.gov (United States)

    Aoki, Hisae; Yamashita, Hiromasa; Mori, Toshiyuki; Fukuyo, Tsuneo; Chiba, Toshio

    2014-11-01

    We developed a new ultrahigh-sensitive CMOS camera using a specific sensor that has a wide range of spectral sensitivity characteristics. The objective of this study is to present our updated endoscopic technology that has successfully integrated two innovative functions; ultrasensitive imaging as well as advanced fluorescent viewing. Two different experiments were conducted. One was carried out to evaluate the function of the ultrahigh-sensitive camera. The other was to test the availability of the newly developed sensor and its performance as a fluorescence endoscope. In both studies, the distance from the endoscopic tip to the target was varied and those endoscopic images in each setting were taken for further comparison. In the first experiment, the 3-CCD camera failed to display the clear images under low illumination, and the target was hardly seen. In contrast, the CMOS camera was able to display the targets regardless of the camera-target distance under low illumination. Under high illumination, imaging quality given by both cameras was quite alike. In the second experiment as a fluorescence endoscope, the CMOS camera was capable of clearly showing the fluorescent-activated organs. The ultrahigh sensitivity CMOS HD endoscopic camera is expected to provide us with clear images under low illumination in addition to the fluorescent images under high illumination in the field of laparoscopic surgery.

  5. Reduced-illuminance autofluorescence imaging in ABCA4-associated retinal degenerations

    Science.gov (United States)

    Cideciyan, Artur V.; Swider, Malgorzata; Aleman, Tomas S.; Roman, Marisa I.; Sumaroka, Alexander; Schwartz, Sharon B.; Stone, Edwin M.; Jacobson, Samuel G.

    2007-05-01

    The health of the retinal pigment epithelium (RPE) can be estimated with autofluorescence (AF) imaging of lipofuscin, which accumulates as a byproduct of retinal exposure to light. Lipofuscin may be toxic to the RPE, and its toxicity may be enhanced by short-wavelength (SW) illumination. The high-intensity and SW excitation light used in conventional AF imaging could, at least in principle, increase the rate of lipofuscin accumulation and/or increase its toxicity. We considered two reduced-illuminance AF imaging (RAFI) methods as alternatives to conventional AF imaging. RAFI methods use either near-infrared (NIR) light or reduced-radiance SW illumination for excitation of fluorophores. We quantified the distribution of RAFI signals in relation to retinal structure and function in patients with the prototypical lipofuscin accumulation disease caused by mutations in ABCA4. There was evidence for two subclinical stages of macular ABCA4 disease involving hyperautofluorescence of both SW- and NIR-RAFI with and without associated loss of visual function. Use of RAFI methods and microperimetry in future clinical trials involving lipofuscinopathies should allow quantification of subclinical disease expression and progression without subjecting the diseased retina/RPE to undue light exposure.

  6. Implementation of real-time digital endoscopic image processing system

    Science.gov (United States)

    Song, Chul Gyu; Lee, Young Mook; Lee, Sang Min; Kim, Won Ky; Lee, Jae Ho; Lee, Myoung Ho

    1997-10-01

    Endoscopy has become a crucial diagnostic and therapeutic procedure in clinical areas. Over the past four years, we have developed a computerized system to record and store clinical data pertaining to endoscopic surgery of laparascopic cholecystectomy, pelviscopic endometriosis, and surgical arthroscopy. In this study, we developed a computer system, which is composed of a frame grabber, a sound board, a VCR control board, a LAN card and EDMS. Also, computer system controls peripheral instruments such as a color video printer, a video cassette recorder, and endoscopic input/output signals. Digital endoscopic data management system is based on open architecture and a set of widely available industry standards; namely Microsoft Windows as an operating system, TCP/IP as a network protocol and a time sequential database that handles both images and speech. For the purpose of data storage, we used MOD and CD- R. Digital endoscopic system was designed to be able to store, recreate, change, and compress signals and medical images. Computerized endoscopy enables us to generate and manipulate the original visual document, making it accessible to a virtually unlimited number of physicians.

  7. Three-dimensional CT endoscopic images of the larynx. Clinical application of helical CT

    International Nuclear Information System (INIS)

    Yumoto, Eiji; Sanuki, Tetsuji; Yasuhara, Yoshifumi; Ochi, Takashi

    1998-01-01

    Twenty-seven patients with several laryngeal ailments underwent helical computed tomography (CT) on 37 occasions. Ten of these 27 patients suffered from unilateral vocal fold paralysis (UVFP). Three-dimensional (3D) images of the laryngeal lumen viewed from various angles were produced for all sets of CT volumetric data, except for three which contained excessive motion artifacts. The present paper examined whether 3D endoscopic images could offer useful diagnostic and therapeutic information about UVFP. The 3D endoscopic images viewed from the tracheal side and the hemilaryngeal images viewed from the opposite side could delineate the vocal folds, ventricular fold and ventricle three-dimensionally. Atrophy and hypotonic changes to the vocal fold and expansion of the ventricle on the affected side were clearly shown. The 3D endoscopic images accurately showed the phonosurgical effects on the laryngeal structures. The 3D endoscopic images could be produced even when the vocal folds could not be observed with conventional endoscopy due to their overadduction. Multiplanar reconstruction (MPR) images in the coronal plane were reconstructed at a right angle to the glottic axis when the whole larynx was deviated. In addition, coronal MPR images showed a better resolution among the different layers of the vocal fold soft tissue than X-ray tomography. In conclusion, 3D endoscopic images combined with coronal MPR images can provide useful diagnostic an therapeutic information about UVFP, although motion artifacts may occur. (author)

  8. Avaliação da autofluorescência do fundo de olho nas distrofias de retina com o aparelho Heidelberg Retina Angiograph2 Evaluation of fundus autofluorescence in hereditary retinal diseases using Heidelberg Retina Angiograph2

    Directory of Open Access Journals (Sweden)

    Monique Côco

    2007-10-01

    Full Text Available OBJETIVOS: Definir características do exame de autofluorescência, verificando sua utilidade no diagnóstico e acompanhamento de distrofias retinianas. MÉTODOS: Participaram do estudo, 28 pacientes, adultos, divididos igualmente em quatro grupos com diagnósticos de doença de Stargardt, distrofia de Cones, retinose pigmentar e voluntários saudáveis para estabelecimento do padrão de normalidade. Em média foram obtidas nove imagens com o filtro para angiofluoresceinografia para a formação da imagem autofluorescente no Heidelberg Retina Angiograph2. As imagens de cada grupo de pacientes foram analisadas para verificar características comuns. RESULTADOS: As imagens fundoscópicas autofluorescentes dos voluntários do grupo controle mostraram área foveal hipoautofluorescente em relação à retina do pólo posterior. As imagens dos portadores de doença de Stargardt, em geral, apresentaram lesão hipoautofluorescente, correspondendo à área macular. As principais alterações da autofluorescência em pacientes com distrofia de cones foram hipoautofluorescência macular com halo hiperautofluorescente. Nos portadores de retinose pigmentar, foram encontrados pigmentos periféricos causando hipoautofluorescência. Na região macular, hipoautofluorescência ou apenas desorganização do pigmento. CONCLUSÃO: O estudo mostrou a existência de padrões de autofluorescência de fundo nas distrofias de retina que permitem o diagnóstico e melhor interpretação da fisiopatogenia destas doenças.PURPOSE: To define characteristics of the fundus autofluorescence examination, verifying usefulness in the diagnosis and care of hereditary retinal diseases. METHODS: 28 patients, adults, divided equally into four groups with diagnoses of Stargardt macular dystrophy, cone dystrophy, retinitis pigmentosa and healthy volunteers for the establishment of the normality pattern. An average of nine images with the filter for fluorescein angiography was obtained

  9. Image segmentation of pyramid style identifier based on Support Vector Machine for colorectal endoscopic images.

    Science.gov (United States)

    Okamoto, Takumi; Koide, Tetsushi; Sugi, Koki; Shimizu, Tatsuya; Anh-Tuan Hoang; Tamaki, Toru; Raytchev, Bisser; Kaneda, Kazufumi; Kominami, Yoko; Yoshida, Shigeto; Mieno, Hiroshi; Tanaka, Shinji

    2015-08-01

    With the increase of colorectal cancer patients in recent years, the needs of quantitative evaluation of colorectal cancer are increased, and the computer-aided diagnosis (CAD) system which supports doctor's diagnosis is essential. In this paper, a hardware design of type identification module in CAD system for colorectal endoscopic images with narrow band imaging (NBI) magnification is proposed for real-time processing of full high definition image (1920 × 1080 pixel). A pyramid style image segmentation with SVMs for multi-size scan windows, which can be implemented on an FPGA with small circuit area and achieve high accuracy, is proposed for actual complex colorectal endoscopic images.

  10. Fundus autofluorescence and the bisretinoids of retina.

    Science.gov (United States)

    Sparrow, Janet R; Wu, Yalin; Nagasaki, Takayuki; Yoon, Kee Dong; Yamamoto, Kazunori; Zhou, Jilin

    2010-11-01

    Imaging of the human fundus of the eye with excitation wavelengths in the visible spectrum reveals a natural autofluorescence, that in a healthy retina originates primarily from the bisretinoids that constitute the lipofuscin of retinal pigment epithelial (RPE) cells. Since the intensity and distribution of fundus autofluorescence is altered in the presence of retinal disease, we have examined the fluorescence properties of the retinal bisretinoids with a view to aiding clinical interpretations. As is also observed for fundus autofluorescence, fluorescence emission from RPE lipofuscin was generated with a wide range of exciting wavelengths; with increasing excitation wavelength, the emission maximum shifted towards longer wavelengths and spectral width was decreased. These features are consistent with fluorescence generation from a mixture of compounds. While the bisretinoids that constitute RPE lipofuscin all fluoresced with maxima that were centered around 600 nm, fluorescence intensities varied when excited at 488 nm, the excitation wavelength utilized for fundus autofuorescence imaging. For instance the fluorescence efficiency of the bisretinoid A2-dihydropyridine-phosphatidylethanolamine (A2-DHP-PE) was greater than A2E and relative to both of the latter, all-trans-retinal dimer-phosphatidylethanolamine was weakly fluorescent. On the other hand, certain photooxidized forms of the bisretinoids present in both RPE and photoreceptor cells were more strongly fluorescent than the parent compound. We also sought to evaluate whether diffuse puncta of autofluorescence observed in some retinal disorders of monogenic origin are attributable to retinoid accumulation. However, two retinoids of the visual cycle, all-trans-retinyl ester and all-trans-retinal, did not exhibit fluorescence at 488 nm excitation.

  11. The feasibility of endoscopy-CT image registration in the head and neck without prospective endoscope tracking.

    Directory of Open Access Journals (Sweden)

    W Scott Ingram

    Full Text Available Endoscopic examinations are frequently-used procedures for patients with head and neck cancer undergoing radiotherapy, but radiation treatment plans are created on computed tomography (CT scans. Image registration between endoscopic video and CT could be used to improve treatment planning and analysis of radiation-related normal tissue toxicity. The purpose of this study was to explore the feasibility of endoscopy-CT image registration without prospective physical tracking of the endoscope during the examination.A novel registration technique called Location Search was developed. This technique uses physical constraints on the endoscope's view direction to search for the virtual endoscope coordinates that maximize the similarity between the endoscopic video frame and the virtual endoscopic image. Its performance was tested on phantom and patient images and compared to an established registration technique, Frame-To-Frame Tracking.In phantoms, Location Search had average registration errors of 0.55 ± 0.60 cm for point measurements and 0.29 ± 0.15 cm for object surface measurements. Frame-To-Frame Tracking achieved similar results on some frames, but it failed on others due to the virtual endoscope becoming lost. This weakness was more pronounced in patients, where Frame-To-Frame tracking could not make it through the nasal cavity. On successful patient video frames, Location Search was able to find endoscope positions with an average distance of 0.98 ± 0.53 cm away from the ground truth positions. However, it failed on many frames due to false similarity matches caused by anatomical structural differences between the endoscopic video and the virtual endoscopic images.Endoscopy-CT image registration without prospective physical tracking of the endoscope is possible, but more development is required to achieve an accuracy suitable for clinical translation.

  12. Simultaneous optical coherence tomography and lipofuscin autofluorescence imaging of the retina with a single broadband light source at 480nm

    OpenAIRE

    Jiang, Minshan; Liu, Tan; Liu, Xiaojing; Jiao, Shuliang

    2014-01-01

    We accomplished spectral domain optical coherence tomography and auto-fluorescence microscopy for imaging the retina with a single broadband light source centered at 480 nm. This technique is able to provide simultaneous structural imaging and lipofuscin molecular contrast of the retina. Since the two imaging modalities are provided by the same group of photons, their images are intrinsically registered. To test the capabilities of the technique we periodically imaged the retinas of the same ...

  13. Prevention of increased abnormal fundus autofluorescence with blue light-filtering intraocular lenses.

    Science.gov (United States)

    Nagai, Hiroyuki; Hirano, Yoshio; Yasukawa, Tsutomu; Morita, Hiroshi; Nozaki, Miho; Wolf-Schnurrbusch, Ute; Wolf, Sebastian; Ogura, Yuichiro

    2015-09-01

    To observe changes in fundus autofluorescence 2 years after implantation of blue light-filtering (yellow-tinted) and ultraviolet light-filtering (colorless) intraocular lenses (IOLs). Department of Ophthalmology and Visual Science, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan, and the Department of Ophthalmology, University of Bern, Bern, Switzerland. Prospective comparative observational study. Patients were enrolled who had cataract surgery with implantation of a yellow-tinted or colorless IOL and for whom images were obtained on which the fundus autofluorescence was measurable using the Heidelberg Retina Angiogram 2 postoperatively. The fundus autofluorescence in the images was classified into 8 abnormal patterns based on the classification of the International Fundus Autofluorescence Classification Group, The presence of normal fundus autofluorescence, geographic atrophy, and wet age-related macular degeneration (AMD) also was recorded. The fundus findings at baseline and 2 years postoperatively were compared. Fifty-two eyes with a yellow-tinted IOL and 79 eyes with a colorless IOL were included. Abnormal fundus autofluorescence did not develop or increase in the yellow-tinted IOL group; however, progressive abnormal fundus autofluorescence developed or increased in 12 eyes (15.2%) in the colorless IOL group (P = .0016). New drusen, geographic atrophy, and choroidal neovascularization were observed mainly in the colorless IOL group. The incidence of AMD was statistically significantly higher in the colorless IOL group (P = .042). Two years after cataract surgery, significant differences were seen in the progression of abnormal fundus autofluorescence between the 2 groups. The incidence of AMD was lower in eyes with a yellow-tinted IOL. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. [Digital imaging and robotics in endoscopic surgery].

    Science.gov (United States)

    Go, P M

    1998-05-23

    The introduction of endoscopical surgery has among other things influenced technical developments in surgery. Owing to digitalisation, major progress will be made in imaging and in the sophisticated technology sometimes called robotics. Digital storage makes the results of imaging diagnostics (e.g. the results of radiological examination) suitable for transmission via video conference systems for telediagnostic purposes. The availability of digital video technique renders possible the processing, storage and retrieval of moving images as well. During endoscopical operations use may be made of a robot arm which replaces the camera man. The arm does not grow tired and provides a stable image. The surgeon himself can operate or address the arm and it can remember fixed image positions to which it can return if ordered to do so. The next step is to carry out surgical manipulations via a robot arm. This may make operations more patient-friendly. A robot arm can also have remote control: telerobotics. At the Internet site of this journal a number of supplements to this article can be found, for instance three-dimensional (3D) illustrations (which is the purpose of the 3D spectacles enclosed with this issue) and a quiz (http:@appendix.niwi. knaw.nl).

  15. Development of an integrated filing system for endoscopic images.

    Science.gov (United States)

    Fujino, M A; Ikeda, M; Yamamoto, Y; Kinose, T; Tachikawa, H; Morozumi, A; Sano, S; Kojima, Y; Nakamura, T; Kawai, T

    1991-01-01

    A new integrated filing system for endoscopic images has been developed, comprising a main image filing system and subsystems located at different stations. A hybrid filing system made up of both digital and analog filing devices was introduced to construct this system that combines the merits of the two filing methods. Each subsystem provided with a video processor, is equipped with a digital filing device, and routine images were recorded in the analog image filing device of the main system. The use of a multi-input adapter enabled simultaneous input of analog images from up to 8 video processors. Recorded magneto-optical disks make it possible to recall the digital images at any station in the hospital; the disks are copied without image degradation and also utilised for image processing. This system promises reliable storage and integrated, efficient management of endoscopic information. It also costs less to install than the so-called PACS (picture archiving and communication system), which connects all the stations of the hospital using optical fiber cables.

  16. Noninvasive Quantification of Retinal Microglia Using Widefield Autofluorescence Imaging.

    Science.gov (United States)

    Kokona, Despina; Schneider, Nadia; Giannakaki-Zimmermann, Helena; Jovanovic, Joel; Ebneter, Andreas; Zinkernagel, Martin

    2017-04-01

    To validate widefield autofluorescence (AF) in vivo imaging of the retina in mice expressing green fluorescent protein (gfp) in microglia, and to monitor retinal microglia reconstitution in vivo after lethal irradiation and bone marrow transplantation. Transgenic Cx3cr1gfp/gfp and wildtype Balb/c mice were used in this study. A confocal scanning laser ophthalmoscope was used for AF imaging with a 55° and a widefield 102° lens. Intrasession reproducibility was assessed for each lens. To investigate reconstitution in vivo, bone marrow from Cx3cr1gfp/gfp mice was used to rescue lethally irradiated wildtype mice. Data were compared to confocal microscopy of retinal flat mounts. Both the 55° and the 102° lens produced high resolution images of retinal microglia with similar microglia density. However, compared to the 55° lens, the widefield 102° lens captured approximately 3.6 times more microglia cells (1515 ± 123 cells versus 445 ± 76 cells [mean ± SD], for 102° and 55°, respectively, P < 0.001). No statistical difference in the number of gfp positive cells within corresponding areas was observed within the same imaging session. Imaging of microglia reconstitution showed a similar time course compared to flat mount preparations with an excellent correlation between microglia cell numbers in AF and gfp-stained flat mounts (R = 0.92, P < 0.0001). Widefield AF imaging of mice with gfp expressing microglia can be used to quantify retinal microglia. In vivo microglia counts corresponded very well with ex vivo counts on retinal flat mounts. As such, AF imaging can largely replace ex vivo quantification.

  17. Fundus autofluorescence patterns in primary intraocular lymphoma.

    Science.gov (United States)

    Casady, Megan; Faia, Lisa; Nazemzadeh, Maryam; Nussenblatt, Robert; Chan, Chi-Chao; Sen, H Nida

    2014-02-01

    To evaluate fundus autofluorescence (FAF) patterns in patients with primary intraocular (vitreoretinal) lymphoma. Records of all patients with primary intraocular lymphoma who underwent FAF imaging at the National Eye Institute were reviewed. Fundus autofluorescence patterns were evaluated with respect to clinical disease status and the findings on fluorescein angiography and spectral-domain optical coherence tomography. There were 18 eyes (10 patients) with primary intraocular lymphoma that underwent FAF imaging. Abnormal autofluorescence in the form of granular hyperautofluorescence and hypoautofluorescence was seen in 11 eyes (61%), and blockage by mass lesion was seen in 2 eyes (11%). All eyes with granular pattern on FAF had active primary intraocular lymphoma at the time of imaging, but there were 5 eyes with unremarkable FAF, which were found to have active lymphoma. The most common pattern on fluorescein angiography was hypofluorescent round spots with a "leopard spot" appearance (43%). These hypofluorescent spots on fluorescein angiography correlated with hyperautofluorescent spots on FAF in 5 eyes (36%) (inversion of FAF). Nodular hyperreflective spots at the level of retinal pigment epithelium on optical coherence tomography were noted in 43% of eyes. The hyperautofluorescent spots on FAF correlated with nodular hyperreflective spots on optical coherence tomography in 6 eyes (43%). Granularity on FAF was associated with active lymphoma in majority of the cases. An inversion of FAF (hyperautofluorescent spots on FAF corresponding to hypofluorescent spots on fluorescein angiography) was observed in less than half of the eyes.

  18. Clinical relevance of quantified fundus autofluorescence in diabetic macular oedema.

    Science.gov (United States)

    Yoshitake, S; Murakami, T; Uji, A; Unoki, N; Dodo, Y; Horii, T; Yoshimura, N

    2015-05-01

    To quantify the signal intensity of fundus autofluorescence (FAF) and evaluate its association with visual function and optical coherence tomography (OCT) findings in diabetic macular oedema (DMO). We reviewed 103 eyes of 78 patients with DMO and 30 eyes of 22 patients without DMO. FAF images were acquired using Heidelberg Retina Angiograph 2, and the signal levels of FAF in the individual subfields of the Early Treatment Diabetic Retinopathy Study grid were measured. We evaluated the association between quantified FAF and the logMAR VA and OCT findings. One hundred and three eyes with DMO had lower FAF signal intensity levels in the parafoveal subfields compared with 30 eyes without DMO. The autofluorescence intensity in the parafoveal subfields was associated negatively with logMAR VA and the retinal thickness in the corresponding subfields. The autofluorescence levels in the parafoveal subfield, except the nasal subfield, were lower in eyes with autofluorescent cystoid spaces in the corresponding subfield than in those without autofluorescent cystoid spaces. The autofluorescence level in the central subfield was related to foveal cystoid spaces but not logMAR VA or retinal thickness in the corresponding area. Quantified FAF in the parafovea has diagnostic significance and is clinically relevant in DMO.

  19. The Role of Fundus Autofluorescence in Late-Onset Retinitis Pigmentosa (LORP) Diagnosis

    Science.gov (United States)

    Lee, Tamara J.; Hwang, John C.; Chen, Royce W. S.; Lima, Luiz H.; Wang, Nan-Kai; Tosi, Joaquin; Freund, K. Bailey; Yannuzzi, Lawrence A.; Tsang, Stephen H.

    2015-01-01

    Purpose To demonstrate the utility and characteristics of fundus autofluorescence in late-onset retinitis pigmentosa. Methods Observational case series. Patients diagnosed with late-onset retinitis pigmentosa were identified retrospectively in an institutional setting. Twelve eyes of six patients were identified and medical records were reviewed. Results All patients presented with slowly progressive peripheral field loss and initial clinical examination revealed only subtle retinal changes. There was a notable lack of intraretinal pigment migration in all patients. Five out of six patients underwent magnetic resonance imaging of the brain to rule out intracranial processes and all were referred from another ophthalmologist for further evaluation. Fundus autofluorescence was ultimately employed in all patients and revealed more extensive retinal pathology than initially appreciated on clinical examination. Fundus autofluorescence directed the workup toward a retinal etiology in all cases and led to the eventual diagnosis of late-onset retinitis pigmentosa through electroretinogram testing. Conclusion Fundus autofluorescence may be a more sensitive marker for retinal pathology than stereo fundus biomicroscopy alone in late-onset retinitis pigmentosa. Early use of fundus autofluorescence imaging in the evaluation of patients with subtle retinal lesions and complaints of peripheral field loss may be an effective strategy for timely and cost-efficient diagnosis. PMID:23899229

  20. Correlation between Spectral Optical Coherence Tomography and Fundus Autofluorescence at the margins of Geographic Atrophy

    Science.gov (United States)

    Brar, Manpreet; Kozak, Igor; Cheng, Lingyun; Bartsch, Dirk-Uwe G.; Yuson, Ritchie; Nigam, Nitin; Oster, Stephen F.; Mojana, Francesca; Freeman, William R.

    2009-01-01

    Purpose We studied the appearance of margins of Geographic atrophy in high- resolution optical coherence tomography (OCT) images and correlate those changes with fundus autofluorescence imaging. Design Retrospective observational case study. Methods Patients with geographic atrophy secondary to dry age related macular degeneration (ARMD) were assessed by means of Spectral Domain OCT (Spectralis HRA/OCT; Heidelberg Engineering, Heidelberg, Germany or OTI, Inc, Toronto, Canada) as well as Autofluoresence Imaging (HRA or Spectralis Heidelberg Engineering, Heidelberg, Germany): The outer retinal layer alterations were analyzed in the junctional zone between normal retina and atrophic retina, and correlated with corresponding fundus autofluorescence. Results 23 eyes of 16 patients aged between 62 years to 96 years were examined. There was a significant association between OCT findings and the fundus autofluorescence findings(r=0.67, pautofluorescence; Smooth margins on OCT correspond significantly to normal fundus autofluorescence. (Kappa-0.7348, pautofluorescence; secondary to increased lipofuscin may together serve as determinants of progression of geographic atrophy. PMID:19541290

  1. Computer-based endoscopic image-processing technology for endourology and laparoscopic surgery

    International Nuclear Information System (INIS)

    Igarashi, Tatsuo; Suzuki, Hiroyoshi; Naya, Yukio

    2009-01-01

    Endourology and laparoscopic surgery are evolving in accordance with developments in instrumentation and progress in surgical technique. Recent advances in computer and image-processing technology have enabled novel images to be created from conventional endoscopic and laparoscopic video images. Such technology harbors the potential to advance endourology and laparoscopic surgery by adding new value and function to the endoscope. The panoramic and three-dimensional images created by computer processing are two outstanding features that can address the shortcomings of conventional endoscopy and laparoscopy, such as narrow field of view, lack of depth cue, and discontinuous information. The wide panoramic images show an anatomical map' of the abdominal cavity and hollow organs with high brightness and resolution, as the images are collected from video images taken in a close-up manner. To assist in laparoscopic surgery, especially in suturing, a three-dimensional movie can be obtained by enhancing movement parallax using a conventional monocular laparoscope. In tubular organs such as the prostatic urethra, reconstruction of three-dimensional structure can be achieved, implying the possibility of a liquid dynamic model for assessing local urethral resistance in urination. Computer-based processing of endoscopic images will establish new tools for endourology and laparoscopic surgery in the near future. (author)

  2. Analysis of visual pigment by fundus autofluorescence.

    NARCIS (Netherlands)

    Theelen, T.; Berendschot, T.T.; Boon, C.J.F.; Hoyng, C.B.; Klevering, B.J.

    2008-01-01

    This study investigated changes of short-wavelength fundus autofluorescence (SW-AF) by retinal bleaching effects. All measurements were performed with the Heidelberg Retina Angiograph 2 (HRA 2). Initially, experimental imaging was done on a healthy eye after dark adaptation. Photopigment was

  3. On the autofluorescence of fingermarks

    NARCIS (Netherlands)

    Lambrechts, S. A. G.; van Dam, A. [=Annemieke; de Vos, J.; van Weert, A.; Sijen, T.; Aalders, M. C. G.

    2012-01-01

    The autofluorescence of fingermarks is used for their detection. The components responsible for this autofluorescence are largely unknown. Thin layer chromatography and fluorescence spectroscopy were used to identify autofluorescent components and evaluate their forensic value. Based on our results,

  4. Clinical evaluation of endoscopic trimodal imaging for the detection and differentiation of colonic polyps.

    Science.gov (United States)

    van den Broek, Frank J C; Fockens, Paul; Van Eeden, Susanne; Kara, Mohammed A; Hardwick, James C H; Reitsma, Johannes B; Dekker, Evelien

    2009-03-01

    Endoscopic trimodal imaging (ETMI) incorporates high-resolution endoscopy (HRE) and autofluorescence imaging (AFI) for adenoma detection, and narrow-band imaging (NBI) for differentiation of adenomas from nonneoplastic polyps. The aim of this study was to compare AFI with HRE for adenoma detection and to assess the diagnostic accuracy of NBI for differentiation of polyps. This was a randomized trial of tandem colonoscopies. The study was performed at the Academic Medical Center in Amsterdam. One hundred patients underwent colonoscopy with ETMI. Each colonic segment was examined twice for polyps, once with HRE and once with AFI, in random order per patient. All detected polyps were assessed with NBI for pit pattern and with AFI for color, and subsequently removed. Histopathology served as the gold standard for diagnosis. The main outcome measures of this study were adenoma miss-rates of AFI and HRE, and diagnostic accuracy of NBI and AFI for differentiating adenomas from nonneoplastic polyps. Among 50 patients examined with AFI first, 32 adenomas were detected initially. Subsequent inspection with HRE identified 8 additional adenomas. Among 50 patients examined with HRE first, 35 adenomas were detected initially. Successive AFI yielded 14 additional adenomas. The adenoma miss-rates of AFI and HRE therefore were 20% and 29%, respectively (P = .351). The sensitivity, specificity, and overall accuracy of NBI for differentiation were 90%, 70%, and 79%, respectively; corresponding figures for AFI were 99%, 35%, and 63%, respectively. The overall adenoma miss-rate was 25%; AFI did not significantly reduce the adenoma miss-rate compared with HRE. Both NBI and AFI had a disappointing diagnostic accuracy for polyp differentiation, although AFI had a high sensitivity.

  5. Autofluorescence Lifetimes in Geographic Atrophy in Patients With Age-Related Macular Degeneration.

    Science.gov (United States)

    Dysli, Chantal; Wolf, Sebastian; Zinkernagel, Martin S

    2016-05-01

    To investigate fluorescence lifetime characteristics in patients with geographic atrophy (GA) in eyes with age-related macular degeneration and to correlate the measurements with clinical data and optical coherence tomography (OCT) findings. Patients with GA were imaged with a fluorescence lifetime imaging ophthalmoscope. Retinal autofluorescence lifetimes were measured in a short and a long spectral channel (498-560 nm and 560-720 nm). Mean retinal fluorescence lifetimes were analyzed within GA and the surrounding retina, and data were correlated with best corrected visual acuity and OCT measurements. Fluorescence lifetime maps of 41 eyes of 41 patients (80 ± 7 years) with GA were analyzed. Mean lifetimes within areas of atrophy were prolonged by 624 ± 276 ps (+152%) in the short spectral channel and 418 ± 186 ps (+83%) in the long spectral channel compared to the surrounding tissue. Autofluorescence lifetime abnormalities in GA occurred with particular patterns, similar to those seen in fundus autofluorescence intensity images. Within the fovea short mean autofluorescence lifetimes were observed, presumably representing macular pigment. Short lifetimes were preserved even in the absence of foveal sparing but were decreased in patients with advanced retinal atrophy in OCT. Short lifetimes in the fovea correlated with better best corrected visual acuity in both spectral channels. This study established that autofluorescence lifetime changes in GA present with explicit patterns. We hypothesize that the short lifetimes seen within the atrophy may be used to estimate damage induced by atrophy and to monitor disease progression in the context of natural history or interventional therapeutic studies.

  6. Emphysema. Imaging for endoscopic lung volume reduction

    International Nuclear Information System (INIS)

    Storbeck, B.; Oldigs, M.; Rabe, K.F.; Weber, C.; University Medical Center Hamburg-Eppendorf

    2015-01-01

    Chronic obstructive pulmonary disease (COPD) is characterized by two entities, the more airway-predominant type (''bronchitis'') on the one hand, and emphysema-predominant type on the other. Imaging via high-resolution computed tomography plays an important role in phenotyping COPD. For patients with advanced lung emphysema, new endoscopic lung volume reduction therapies (ELVR) have been developed. Proper selection of suitable patients requires thin-section reconstruction of volumetric CT image data sets also in coronal and sagittal orientation are required. In the current manuscript we will describe emphysema subtypes (centrilobular, paraseptal, panlobular), options for quantifying emphysema and this importance of regional distribution (homogeneous or heterogeneous, target area) as this is crucial for patient selection. Analysis of the interlobular fissures is obligatory despite the lack of standardization, as incomplete fissures indicate collateral ventilation (CV) via parenchymal bridges, which is an important criterion in choosing endoscopic methods of LVR. Every radiologist should be familiar with modern LVR therapies such as valves and coils, and furthermore should know what a lung doctor expects from radiologic evaluation (before and after ELVR). Finally we present a checklist as a quick reference for all steps concerning imaging for ELVR.

  7. Fundus autofluorescence: applications and perspectives.

    Science.gov (United States)

    Cuba, J; Gómez-Ulla, F

    2013-02-01

    To describe the findings of the study of autofluorescence of the different retinal diseases included in the study. To determine in which diseases autofluorescence may be more, or just as, useful as fluorescein angiography (FAG) in terms of diagnostic information. We studied the retinal autofluorescence of 123 eyes of 93 patients, including various diseases of the eye fundus. In all cases we explored the fundus, retinal autofluorescence, and, if indicated, FAG was performed. Analysis of the autofluorescence was performed using the Heidelberg Retina angiography Angiograph 2 (HRA2) Heidelberg Engineering (Germany). The autofluorescence information provided was equal or better (than FAG) in: 68.18% of cases of macular edema, 50% of pigment epithelium detachments, 100% of pigment epithelium atrophies, 100% of central serous chorioretinopathy; 55.55% of choroidal neovascularization, 100% of retinal dystrophies with deposition of lipofuscin, 100% of hard exudates and pre-retinal hemorrhages. Autofluorescence is a quick and non-invasive examination method, comfortable for both patient and examiner, and with a very short learning curve. It provides diagnostic information about many eye fundus diseases. While more studies and more experience with its use are needed, its interest lies in the possibility of avoiding the performing of angiography in patients with these diseases, and in the additional information autofluorescence provides about the functional situation of cells and retinal pigments. Copyright © 2011 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  8. Image-based navigation for a robotized flexible endoscope

    NARCIS (Netherlands)

    van der Stap, N.; Slump, Cornelis H.; Broeders, Ivo Adriaan Maria Johannes; van der Heijden, Ferdinand; Luo, Xiongbiao; Reichl, Tobias; Mirota, Daniel; Soper, Timothy

    2014-01-01

    Robotizing flexible endoscopy enables image-based control of endoscopes. Especially during high-throughput procedures, such as a colonoscopy, navigation support algorithms could improve procedure turnaround and ergonomics for the endoscopist. In this study, we have developed and implemented a

  9. Imaging of common bile duct by linear endoscopic ultrasound

    Institute of Scientific and Technical Information of China (English)

    Malay; Sharma; Amit; Pathak; Abid; Shoukat; Chittapuram; Srinivasan; Rameshbabu; Akash; Ajmera; Zeeshn; Ahamad; Wani; Praveer; Rai

    2015-01-01

    Imaging of common bile duct(CBD) can be done by many techniques. Endoscopic retrograde cholangiopancreaticography is considered the gold standard for imaging of CBD. A standard technique of imaging of CBD by endoscopic ultrasound(EUS) has not been specifically described. The available descriptions mention different stations of imaging from the stomach and duodenum. The CBD lies closest to duodenum and choice of imaging may be restricted to duodenum for many operators. Generally most operators prefer multi station imaging during EUS and the choice of selecting the initial station varies from operator to operator. Detailed evaluation of CBD is frequently the main focus of imaging during EUS and in such situations multi station imaging with a high-resolution ultrasound scanner may provide useful information. Examination of the CBD is one of the primary indications for doing an EUS and it can be done from five stations:(1) the fundus of stomach;(2) body of stomach;(3) duodenal bulb;(4) descending duodenum; and(5) antrum. Following down the upper 1/3rd of CBD can do imaging of entire CBD from the liver window and following up the lower 1/3rd of CBD can do imaging of entire CBD from the pancreatic window. This article aims at simplifying the techniques of imaging of CBD by linear EUS.

  10. Neuro-fuzzy Classification System for Wireless-Capsule Endoscopic Images

    OpenAIRE

    Vassilis S. Kodogiannis; John N. Lygouras

    2008-01-01

    In this research study, an intelligent detection system to support medical diagnosis and detection of abnormal lesions by processing endoscopic images is presented. The images used in this study have been obtained using the M2A Swallowable Imaging Capsule - a patented, video color-imaging disposable capsule. Schemes have been developed to extract texture features from the fuzzy texture spectra in the chromatic and achromatic domains for a selected region of interest from ...

  11. Autofluorescence and spectral-domain optical coherence tomography of optic disk melanocytoma.

    Science.gov (United States)

    Guerra, Ricardo Luz Leitão; Marback, Eduardo Ferrari; Silva, Igor Sandes Pessoa da; Maia Junior, Otacílio de Oliveira; Marback, Roberto Lorens

    2014-01-01

    The authors report fundus autofluorescence (FAF) and spectral-domain optical coherence tomography (OCT) findings of two consecutive patients who presented with optic disk melanocytoma (ODM). A retrospective study was performed by reviewing medical records and ophthalmic imaging examinations. Optical coherence tomography findings were sloped and brightly reflective anterior tumor surface, adjacent retinal desorganization and abrupt posterior optical shadowing. Vitreous seeds were found in one patient. Fundus autofluorescence revealed outstanding hypoautofluorescence at the tumor area and isoautofluorescence at the remaining retina. Optical coherence tomography findings of the reported cases are consistent with those reported in the reviewed literature. Fundus autofluorescence has been used in the assessment of choroidal melanocytic tumors, but not yet in melanocytomas. We assume that this is the first report of these findings and believe that when its pattern has become clearly defined, fundus autofluorescence will be a useful tool to avoid misdiagnosis in suspicious cases and for follow-up.

  12. Autofluorescence and spectral-domain optical coherence tomography of optic disk melanocytoma

    Directory of Open Access Journals (Sweden)

    Ricardo Luz Leitão Guerra

    2014-12-01

    Full Text Available The authors report fundus autofluorescence (FAF and spectral-domain optical coherence tomography (OCT findings of two consecutive patients who presented with optic disk melanocytoma (ODM. A retrospective study was performed by reviewing medical records and ophthalmic imaging examinations. Optical coherence tomography findings were sloped and brightly reflective anterior tumor surface, adjacent retinal desorganization and abrupt posterior optical shadowing. Vitreous seeds were found in one patient. Fundus autofluorescence revealed outstanding hypoautofluorescence at the tumor area and isoautofluorescence at the remaining retina. Optical coherence tomography findings of the reported cases are consistent with those reported in the reviewed literature. Fundus autofluorescence has been used in the assessment of choroidal melanocytic tumors, but not yet in melanocytomas. We assume that this is the first report of these findings and believe that when its pattern has become clearly defined, fundus autofluorescence will be a useful tool to avoid misdiagnosis in suspicious cases and for follow-up.

  13. Endoscopic device for functional imaging of the retina

    Science.gov (United States)

    Barriga, Simon; Lohani, Sweyta; Martell, Bret; Soliz, Peter; Ts'o, Dan

    2011-03-01

    Non-invasive imaging of retinal function based on the recording of spatially distributed reflectance changes evoked by visual stimuli has to-date been performed primarily using modified commercial fundus cameras. We have constructed a prototype retinal functional imager, using a commercial endoscope (Storz) for the frontend optics, and a low-cost back-end that includes the needed dichroic beam splitter to separate the stimulus path from the imaging path. This device has been tested to demonstrate its performance for the delivery of adequate near infrared (NIR) illumination, intensity of the visual stimulus and reflectance return in the imaging path. The current device was found to be capable of imaging reflectance changes of 0.1%, similar to that observable using the modified commercial fundus camera approach. The visual stimulus (a 505nm spot of 0.5secs) was used with an interrogation illumination of 780nm, and a sequence of imaged captured. At each pixel, the imaged signal was subtracted and normalized by the baseline reflectance, so that the measurement was ΔR/R. The typical retinal activity signal observed had a ΔR/R of 0.3-1.0%. The noise levels were measured when no stimulus was applied and found to vary between +/- 0.05%. Functional imaging has been suggested as a means to provide objective information on retina function that may be a preclinical indicator of ocular diseases, such as age-related macular degeneration (AMD), glaucoma, and diabetic retinopathy. The endoscopic approach promises to yield a significantly more economical retinal functional imaging device that would be clinically important.

  14. Multi-site and multi-depth in vivo cancer localization enhancement after auto-fluorescence removal

    International Nuclear Information System (INIS)

    Montcuquet, A.S.; Herve, L.; Navarro, F.; Dinten, J.M.; Mars, J.I.

    2011-01-01

    Fluorescence imaging in diffusive media locates tumors tagged by injected fluorescent markers in NIR wavelengths. For deep embedded markers, natural auto-fluorescence of tissues comes to be a limiting factor to tumor detection and accurate FDOT reconstructions. A spectroscopic approach coupled with Non-negative Matrix Factorization source separation method is explored to discriminate fluorescence sources according to their fluorescence spectra and remove unwanted auto-fluorescence. We successfully removed auto-fluorescence from acquisitions on living mice with a single subcutaneous tumor or two capillary tubes inserted at different depths. (authors)

  15. Autofluorescence in samples obtained from chronic biofilm infections – “all that glitters is not gold”

    DEFF Research Database (Denmark)

    Eickhardt-Dalbøge, Steffen Robert; Kragh, Kasper N.; Schrøder, Stine

    2015-01-01

    When looking at tissue sections of ex vivo samples, autofluorescence can be a major cause of artifacts and misinterpretations. We here reiterate evidence that autofluorescing granules, often hemosiderin but also ceroid or mucinogen granules, are severe obstacles when imaging and diagnosing biofil...

  16. Autofluorescence of pigmented skin lesions using a pulsed UV laser with synchronized detection: clinical results

    DEFF Research Database (Denmark)

    Cheng, Haynes Pak Hay; Svenmarker, Pontus; Tidemand-Lichtenberg, Peter

    2010-01-01

    signal, which may in turn produce high contrast images that improve diagnosis, even in the presence of ambient room light. The synchronized set-up utilizes a compact, diode pumped, pulsed UV laser at 355 nm which is coupled to a CCD camera and a liquid crystal tunable filter. The excitation and image......We report preliminary clinical results of autofluorescence imaging of malignant and benign skin lesions, using pulsed 355 nm laser excitation with synchronized detection. The novel synchronized detection system allows high signal-to-noise ratio to be achieved in the resulting autofluorescence...

  17. FUNDUS AUTOFLUORESCENCE IN RUBELLA RETINOPATHY: Correlation With Photoreceptor Structure and Function.

    Science.gov (United States)

    Bukowska, Danuta M; Wan, Sue Ling; Chew, Avenell L; Chelva, Enid; Tang, Ivy; Mackey, David A; Chen, Fred K

    2017-01-01

    To illustrate altered fundus autofluorescence in rubella retinopathy and to investigate their relationships with photoreceptor structure and function using multimodal imaging. The authors report four cases of rubella retinopathy aged 8, 33, 42, and 50 years. All patients had dilated clinical fundus examination; wide-field color photography; blue, green, and near-infrared autofluorescence imaging and spectral domain optical coherence tomography. Two patients also underwent microperimetry and adaptive optics imaging. En face optical coherence tomography, cone mosaic, and microperimetry were coregistered with autofluorescence images. The authors explored the structure-function correlation. All four patients had a "salt-and-pepper" appearance on dilated fundus examination and wide-field color photography. There were variable-sized patches of hypoautofluorescence on both blue and near-infrared excitation in all four patients. Wave-guiding cones were visible and retinal sensitivity was intact over these regions. There was no correlation between hypoautofluorescence and regions of attenuated ellipsoid and interdigitation zones. Hyperautofluorescent lesions were also noted and some of these were pseudo-vitelliform lesions. Patchy hypoautofluorescence on near-infrared excitation can be a feature of rubella retinopathy. This may be due to abnormal melanin production or loss of melanin within retinal pigment epithelium cells harboring persistent rubella virus infection. Preservation of the ellipsoid zone, wave-guiding cones, and retinal sensitivity within hypoautofluorescent lesions suggest that these retinal pigment epithelium changes have only mild impact on photoreceptor cell function.

  18. 4-mm-diameter three-dimensional imaging endoscope with steerable camera for minimally invasive surgery (3-D-MARVEL).

    Science.gov (United States)

    Bae, Sam Y; Korniski, Ronald J; Shearn, Michael; Manohara, Harish M; Shahinian, Hrayr

    2017-01-01

    High-resolution three-dimensional (3-D) imaging (stereo imaging) by endoscopes in minimally invasive surgery, especially in space-constrained applications such as brain surgery, is one of the most desired capabilities. Such capability exists at larger than 4-mm overall diameters. We report the development of a stereo imaging endoscope of 4-mm maximum diameter, called Multiangle, Rear-Viewing Endoscopic Tool (MARVEL) that uses a single-lens system with complementary multibandpass filter (CMBF) technology to achieve 3-D imaging. In addition, the system is endowed with the capability to pan from side-to-side over an angle of [Formula: see text], which is another unique aspect of MARVEL for such a class of endoscopes. The design and construction of a single-lens, CMBF aperture camera with integrated illumination to generate 3-D images, and the actuation mechanism built into it is summarized.

  19. Assessment of colonoscopy by use of magnetic endoscopic imaging

    DEFF Research Database (Denmark)

    Nerup, Nikolaj; Preisler, Louise; Svendsen, Morten Bo Søndergaard

    2015-01-01

    and a difficult case. SETTING: Center for Clinical Education, Capital Region of Denmark. MAIN OUTCOME MEASUREMENTS: By using magnetic endoscopic imaging, we developed a colonoscopy progression score (CoPS). A pass/fail score was established by using the contrast-group method. RESULTS: We found significant...... differences in performance between the 2 groups using the CoPS in both case scenarios (easy: P heterogeneity of the experienced group resulted in a high passing score for the difficult case, which led to the failing of the less experienced...... in the group. The CoPS does not consider polyp detection rate, tissue damage, or patient discomfort. CONCLUSIONS: We developed a score of progression in colonoscopy, based on magnetic endoscopic imaging. With the same tool, a map of progression in colonoscopy can be provided. The CoPS and map of progression...

  20. Early simultaneous fundus autofluorescence and optical coherence tomography features after pars plana vitrectomy for primary rhegmatogenous retinal detachment.

    Science.gov (United States)

    Dell'Omo, Roberto; Mura, Marco; Lesnik Oberstein, Sarit Y; Bijl, Heico; Tan, H Stevie

    2012-04-01

    To describe fundus autofluorescence and optical coherence tomography (OCT) features of the macula after pars plana vitrectomy for rhegmatogenous retinal detachment. Thirty-three eyes of 33 consecutive patients with repaired rhegmatogenous retinal detachment with or without the involvement of the macula were prospectively investigated with simultaneous fundus autofluorescence and OCT imaging using the Spectralis HRA+OCT (Heidelberg Engineering, Heidelberg, Germany) within a few weeks after the operation. Fundus autofluorescence imaging of the macula showed lines of increased and decreased autofluorescence in 19 cases (57.6%). On OCT, these lines corresponded to the following abnormalities: outer retinal folds, inner retinal folds, and skip reflectivity abnormalities of the photoreceptor inner segment/outer segment band. Other OCT findings, not related to abnormal lines on fundus autofluorescence, consisted of disruption of photoreceptor inner segment/outer segment band and collection of intraretinal or subretinal fluid. The presence of outer retinal folds significantly related to metamorphopsia but did not relate to poor postoperative visual acuity. Partial-thickness retinal folds occur commonly after vitrectomy for rhegmatogenous retinal detachment repair and may represent an important anatomical substrate for postoperative metamorphopsia. Fundus autofluorescence and OCT are both sensitive techniques for the detection of these abnormalities.

  1. Comparative study between fundus autofluorescence and red reflectance imaging of choroidal nevi using ultra-wide-field scanning laser ophthalmoscopy.

    Science.gov (United States)

    Zapata, Miguel Angel; Leila, Mahmoud; Teixidor, Teresa; Garcia-Arumi, Jose

    2015-06-01

    To explore the utility of fundus autofluorescence (FAF) and red reflectance (RR) imaging using ultra-wide-field scanning laser ophthalmoscope in choroidal nevi. Retrospective observational case study reviewing clinical data, color, FAF, and RR images of patients with choroidal nevi and comparing the findings. The ultra-wide-field scanning laser ophthalmoscope uses green laser 532 nm and red laser 633 nm that enabled FAF and RR imaging, respectively in separate channels. Superimposition of both images yielded a composite color image. The study included 46 eyes of 45 patients. Nevi were unilateral in 44 patients (98%). Forty-one nevi (89.1%) were located temporally between the macula and the equator. All nevi (100%) were deeply pigmented. The most frequent surface changes were lipofuscin pigments, zones of retinal pigment epithelium atrophy, and retinal pigment epithelium pigment clumps in 31 (67.3%), 18 (39.1%), and 8 eyes (17.3%), respectively. Color photographs were superior to FAF in detecting nevus boundaries and surface changes. Red reflectance correlated strongly with color images, although the nevus boundaries and surface changes were better delineated in RR mode. Red reflectance was superior to FAF in delineating the boundaries and surface changes of the nevus; clear visibility (3+) for RR versus no or poor visibility (0/1+) for FAF. Nevertheless, the areas of retinal pigment epithelium atrophy were better delineated in FAF mode; clear visibility (3+) for FAF versus poor visibility (1+) for FAF. Red reflectance imaging is more sensitive than conventional photography for follow-up of choroidal nevi. Fundus autofluorescence should be considered only as a complementary tool to RR imaging.

  2. Endoscopic optical coherence tomography for imaging the tympanic membrane

    Science.gov (United States)

    Burkhardt, Anke; Walther, Julia; Cimalla, Peter; Bornitz, Matthias; Koch, Edmund

    2011-06-01

    Optical coherence tomography (OCT) is an imaging modality that enables micrometer-scale contactless subsurface imaging of biological tissue. Endoscopy, as another imaging method, has the potential of imaging tubular organs and cavities and therefore has opened up several application areas not accessible before. The combination of OCT and endoscopy uses the advantages of both methods and consequently allows additional imaging of structures beneath surfaces inside cavities. Currently, visual investigations on the surface of the human tympanic membrane are possible but only with expert eyes. up to now, visual imaging of the outer ear up to the tympanic membrane can be carried out by an otoscope, an operating microscope or an endoscope. In contrast to these devices, endoscopy has the advantage of imaging the whole tympanic membrane with one view. The intention of this research is the development of an endoscopic optical coherence tomography (EOCT) device for imaging the tympanic membrane depth-resolved and structures behind it. Detection of fluids in the middle ear, which function as an indicator for otitis media, could help to avoid the application of antibiotics. It is possible to detect a congeries of fluids with the otoscope but the ambition is to the early detection by OCT. The developed scanner head allows imaging in working distances in the range from zero up to 5 mm with a field of view of 2 mm. In the next step, the scanner head should be improved to increase the working distance and the field of view.

  3. Fundus autofluorescence and optical coherence tomography findings in thiamine responsive megaloblastic anemia.

    Science.gov (United States)

    Ach, Thomas; Kardorff, Rüdiger; Rohrschneider, Klaus

    2015-01-01

    To report ophthalmologic fundus autofluorescence and spectral domain optical coherence tomography findings in a patient with thiamine responsive megaloblastic anemia (TRMA). A 13-year-old girl with genetically proven TRMA was ophthalmologically (visual acuity, funduscopy, perimetry, electroretinogram) followed up over >5 years. Fundus imaging also included autofluorescence and spectral domain optical coherence tomography. During a 5-year follow-up, visual acuity and visual field decreased, despite a special TRMA diet. Funduscopy revealed bull's eye appearance, whereas fundus autofluorescence showed central and peripheral hyperfluorescence and perifoveal hypofluorescence. Spectral domain optical coherence tomography revealed affected inner segment ellipsoid band and irregularities in the retinal pigment epithelium and choroidea. Autofluorescence and spectral domain optical coherence tomography findings in a patient with TRMA show retinitis pigmentosa-like retina, retinal pigment epithelium, and choroid alterations. These findings might progress even under special TRMA diet, indispensable to life. Ophthalmologist should consider TRMA in patients with deafness and ophthalmologic disorders.

  4. A deep learning approach for detecting and correcting highlights in endoscopic images

    NARCIS (Netherlands)

    Rodriguez-Sanchez, Antonio; Chea, Daly; Azzopardi, George; Stabinger, Sebastian

    2017-01-01

    The image of an object changes dramatically depending on the lightning conditions surrounding that object. Shadows, reflections and highlights can make the object very difficult to be recognized for an automatic system. Additionally, images used in medical applications, such as endoscopic images and

  5. Simultaneous optical coherence tomography and lipofuscin autofluorescence imaging of the retina with a single broadband light source at 480nm.

    Science.gov (United States)

    Jiang, Minshan; Liu, Tan; Liu, Xiaojing; Jiao, Shuliang

    2014-12-01

    We accomplished spectral domain optical coherence tomography and auto-fluorescence microscopy for imaging the retina with a single broadband light source centered at 480 nm. This technique is able to provide simultaneous structural imaging and lipofuscin molecular contrast of the retina. Since the two imaging modalities are provided by the same group of photons, their images are intrinsically registered. To test the capabilities of the technique we periodically imaged the retinas of the same rats for four weeks. The images successfully demonstrated lipofuscin accumulation in the retinal pigment epithelium with aging. The experimental results showed that the dual-modal imaging system can be a potentially powerful tool in the study of age-related degenerative retinal diseases.

  6. Autofluorescence of choroidal nevus in 64 cases.

    Science.gov (United States)

    Shields, Carol L; Pirondini, Cesare; Bianciotto, Carlos; Materin, Miguel A; Harmon, Sarah A; Shields, Jerry A

    2008-10-01

    To describe the autofluorescence features of choroidal nevi. Noncomparative case series. Sixty-four consecutive patients. Correlation of fundus photography with autofluorescence photography. Autofluorescence features of choroidal nevus and overlying retinal pigment epithelium (RPE). The mean patient age was 62 years. The choroidal nevus was a mean of 5 mm from the optic disk and foveola. The mean tumor basal dimension was 5.0 mm and mean tumor thickness was 1.0 mm. The choroidal nevus showed hypoautofluorescence in 56%, isoautofluorescence in 19%, and hyperautofluorescence in 25%. The autofluorescence features appeared unaffected by tumor thickness, but increasing tumor base and disrupted overlying RPE appeared to produce slightly brighter autofluorescence. Nevi located in the macular region showed darker hypoautofluorescence than those outside the macular region. Overlying RPE hyperplasia, atrophy, and fibrous metaplasia were generally hypoautofluorescent. Drusen, subretinal fluid, and orange pigment were generally hyperautofluorescent. The brightest hyperautofluorescence was found with orange pigment. Choroidal nevus shows little intrinsic autofluorescence. Overlying RPE alterations show dramatic autofluorescence ranging from dark hypoautofluorescence of RPE atrophy to bright hyperautofluorescence of orange pigment.

  7. Averaged subtracted polarization imaging for endoscopic diagnostics of surface microstructures on translucent mucosae

    Science.gov (United States)

    Kanamori, Katsuhiro

    2016-07-01

    An endoscopic image processing technique for enhancing the appearance of microstructures on translucent mucosae is described. This technique employs two pairs of co- and cross-polarization images under two different linearly polarized lights, from which the averaged subtracted polarization image (AVSPI) is calculated. Experiments were then conducted using an acrylic phantom and excised porcine stomach tissue using a manual experimental setup with ring-type lighting, two rotating polarizers, and a color camera; better results were achieved with the proposed method than with conventional color intensity image processing. An objective evaluation method that uses texture analysis was developed and used to evaluate the enhanced microstructure images. This paper introduces two types of online, rigid-type, polarimetric endoscopic implementations using a polarized ring-shaped LED and a polarimetric camera. The first type uses a beam-splitter-type color polarimetric camera, and the second uses a single-chip monochrome polarimetric camera. Microstructures on the mucosa surface were enhanced robustly with these online endoscopes regardless of the difference in the extinction ratio of each device. These results show that polarimetric endoscopy using AVSPI is both effective and practical for hardware implementation.

  8. The segmentation of zones with increased autofluorescence in the junctional zone of parapapillary atrophy

    International Nuclear Information System (INIS)

    Kolář, R; Jan, J; Laemmer, R; Mardin, Ch Y

    2009-01-01

    The autofluorescence (AF) derived from the retinal pigment epithelium has the potential to be used as a feature for early glaucoma diagnosis. The aim of this paper is to design and evaluate the method used for semi-automatic segmentation of the zones with increased autofluorescence. A randomized sample of 20 patients (age: 56 ± 10 years) with open angle glaucoma was used. A new method for semi-automatic detection and segmentation of the zones with a higher level of autofluorescence in the junctional zone of parapapillary atrophy has been evaluated. Good agreement has been observed between manually and semi-automatically segmented zones for most of the images, but higher differences may occur for larger hyperfluorescent regions. The data were evaluated using the limits of agreement, with a 2σ border. The described method allows fast and objective evaluation of AF images, preventing undesirable inter-expert variance. A large proportion of AF images could be evaluated successfully by the developed procedure, and the obtained results are comparable to the manual procedure in most cases

  9. Automatic specular reflections removal for endoscopic images

    Science.gov (United States)

    Tan, Ke; Wang, Bin; Gao, Yuan

    2017-07-01

    Endoscopy imaging is utilized to provide a realistic view about the surfaces of organs inside the human body. Owing to the damp internal environment, these surfaces usually have a glossy appearance showing specular reflections. For many computer vision algorithms, the highlights created by specular reflections may become a significant source of error. In this paper, we present a novel method for restoration of the specular reflection regions from a single image. Specular restoration process starts with generating a substitute specular-free image with RPCA method. Then the specular removed image was obtained by taking the binary weighting template of highlight regions as the weighting for merging the original specular image and the substitute image. The modified template was furthermore discussed for the concealment of artificial effects in the edge of specular regions. Experimental results on the removal of the endoscopic image with specular reflections demonstrate the efficiency of the proposed method comparing to the existing methods.

  10. Quantitative Autofluorescence Intensities in Acute Zonal Occult Outer Retinopathy vs Healthy Eyes

    Science.gov (United States)

    Boudreault, Katherine; Schuerch, Kaspar; Zhao, Jin; Lee, Winston; Cabral, Thiago; Yannuzzi, Lawrence A.; Tsang, Stephen H.; Sparrow, Janet R.

    2018-01-01

    IMPORTANCE Acute zonal occult outer retinopathy (AZOOR) remains a challenging diagnosis. Early recognition of the disease depends on advances in imaging modalities that can improve phenotyping and contribute to the understanding of the underlying pathogenesis. OBJECTIVES To expand the range of approaches available to assist in the identification of AZOOR by multimodal imaging and to analyze the fundus lesions by quantifying short-wavelength fundus autofluorescence (quantitative fundus autofluorescence [qAF]) and spectral-domain optical coherence tomography. DESIGN, SETTING, AND PARTICIPANTS In this observational study, patients underwent imaging at Columbia University Medical Center between November 2010 and March 2016 and were analyzed between September 2015 and August 2016. Six patients diagnosed as having AZOOR were studied by qAF and spectral-domain optical coherence tomography and were compared with 30 age and race/ethnicity–matched controls from a database of 277 healthy control eyes. MAIN OUTCOMES AND MEASURES In unaffected regions of the macula, qAF was calculated within predetermined circularly arranged segments (qAF8). In addition, qAF was measured within specified regions of interest positioned at the autofluorescent lesion border (AZOOR line). Electroretinograms and electro-oculograms were recorded in 5 of 6 patients. RESULTS Among 6 patients (age range, 26–61 years; 4 female; 4 of white race/ethnicity, 1 Asian, and 1 Hispanic), 5 exhibited an autofluorescent AZOOR line in short-wavelength fundus autofluorescence images, delineating the peripapillary lesion. The mean (SD) region-of-interest qAF measured on the AZOOR line was 60 (26) times higher than in healthy control eyes (P = .03) at equivalent fundus locations. The qAF8 within nondiseased macular regions were within the normal range. At the lesion border, spectral-domain optical coherence tomography revealed a loss of outer retinal integrity in all patients. Single-flash cone b-wave latency and

  11. Intraretinal Correlates of Reticular Pseudodrusen Revealed by Autofluorescence and En Face OCT.

    Science.gov (United States)

    Paavo, Maarjaliis; Lee, Winston; Merriam, John; Bearelly, Srilaxmi; Tsang, Stephen; Chang, Stanley; Sparrow, Janet R

    2017-09-01

    We sought to determine whether information revealed from the reflectance, autofluorescence, and absorption properties of RPE cells situated posterior to reticular pseudodrusen (RPD) could provide insight into the origins and structure of RPD. RPD were studied qualitatively by near-infrared fundus autofluorescence (NIR-AF), short-wavelength fundus autofluorescence (SW-AF), and infrared reflectance (IR-R) images, and the presentation was compared to horizontal and en face spectral domain optical coherence tomographic (SD-OCT) images. Images were acquired from 23 patients (39 eyes) diagnosed with RPD (mean age 80.7 ± 7.1 [SD]; 16 female; 4 Hispanics, 19 non-Hispanic whites). In SW-AF, NIR-AF, and IR-R images, fundus RPD were recognized as interlacing networks of small scale variations in IR-R and fluorescence (SW-AF, NIR-AF) intensities. Darkened foci of RPD colocalized in SW-AF and NIR-AF images, and in SD-OCT images corresponded to disturbances of the interdigitation (IZ) and ellipsoid (EZ) zones and to more pronounced hyperreflective lesions traversing photoreceptor-attributable bands in SD-OCT images. Qualitative assessment of the outer nuclear layer (ONL) revealed thinning as RPD extended radially from the outer to inner retina. In en face OCT, hyperreflective areas in the EZ band correlated topographically with hyporeflective foci at the level of the RPE. The hyperreflective lesions corresponding to RPD in SD-OCT scans are likely indicative of degenerating photoreceptor cells. The darkened foci at positions of RPD in NIR-AF and en face OCT images indicate changes in the RPE monolayer with the reduced NIR-AF and en face OCT signal suggesting a reduction in melanin that could be accounted for by RPE thinning.

  12. Imaging of Mucosal Inflammation: Current Technological Developments, Clinical Implications, and Future Perspectives

    Directory of Open Access Journals (Sweden)

    Maximilian J. Waldner

    2017-10-01

    Full Text Available In recent years, various technological developments markedly improved imaging of mucosal inflammation in patients with inflammatory bowel diseases. Although technological developments such as high-definition-, chromo-, and autofluorescence-endoscopy led to a more precise and detailed assessment of mucosal inflammation during wide-field endoscopy, probe-based and stationary confocal laser microscopy enabled in vivo real-time microscopic imaging of mucosal surfaces within the gastrointestinal tract. Through the use of fluorochromes with specificity against a defined molecular target combined with endoscopic techniques that allow ultrastructural resolution, molecular imaging enables in vivo visualization of single molecules or receptors during endoscopy. Molecular imaging has therefore greatly expanded the clinical utility and applications of modern innovative endoscopy, which include the diagnosis, surveillance, and treatment of disease as well as the prediction of the therapeutic response of individual patients. Furthermore, non-invasive imaging techniques such as computed tomography, magnetic resonance imaging, scintigraphy, and ultrasound provide helpful information as supplement to invasive endoscopic procedures. In this review, we provide an overview on the current status of advanced imaging technologies for the clinical non-invasive and endoscopic evaluation of mucosal inflammation. Furthermore, the value of novel methods such as multiphoton microscopy, optoacoustics, and optical coherence tomography and their possible future implementation into clinical diagnosis and evaluation of mucosal inflammation will be discussed.

  13. Scanning laser ophthalmoscope measurement of local fundus reflectance and autofluorescence changes arising from rhodopsin bleaching and regeneration.

    Science.gov (United States)

    Morgan, Jessica I W; Pugh, Edward N

    2013-03-01

    We measured the bleaching and regeneration kinetics of rhodopsin in the living human eye with two-wavelength, wide-field scanning laser ophthalmoscopy (SLO), and investigated the effect of rhodopsin bleaching on autofluorescence intensity. The retina was imaged with an Optos P200C SLO by its reflectance of 532 and 633 nm light, and its autofluorescence excited by 532 nm light, before and after exposure to lights calibrated to bleach rhodopsin substantially. Bleaching was confined to circular retinal regions of 4.8° visual angle located approximately 16° superotemporal and superonasal to fixation. Images were captured as 12-bit tiff files and postprocessed to extract changes in reflectance and autofluorescence. At the locus of bleaching transient increases in reflectance of the 532 nm, but not the 633 nm beam were observed readily and quantified. A transient increase in autofluorescence also occurred. The action spectrum, absolute sensitivity, and recovery of the 532 nm reflectance increase were consistent with previous measurements of human rhodopsin's spectral sensitivity, photosensitivity, and regeneration kinetics. The autofluorescence changes closely tracked the changes in rhodopsin density. The bleaching and regeneration kinetics of rhodopsin can be measured locally in the human retina with a widely available SLO. The increased autofluorescence excited by 532 nm light upon bleaching appears primarily due to transient elimination of rhodopsin's screening of autofluorescent fluorochromes in the RPE. The spatially localized measurement with a widely available SLO of rhodopsin, the most abundant protein in the retina, could be a valuable adjunct to retinal health assessment.

  14. Ultrahigh speed en face OCT capsule for endoscopic imaging.

    Science.gov (United States)

    Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G

    2015-04-01

    Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications.

  15. WE-AB-BRA-12: Virtual Endoscope Tracking for Endoscopy-CT Image Registration

    International Nuclear Information System (INIS)

    Ingram, W; Rao, A; Wendt, R; Court, L; Yang, J; Beadle, B

    2015-01-01

    Purpose: The use of endoscopy in radiotherapy will remain limited until we can register endoscopic video to CT using standard clinical equipment. In this phantom study we tested a registration method using virtual endoscopy to measure CT-space positions from endoscopic video. Methods: Our phantom is a contorted clay cylinder with 2-mm-diameter markers in the luminal surface. These markers are visible on both CT and endoscopic video. Virtual endoscope images were rendered from a polygonal mesh created by segmenting the phantom’s luminal surface on CT. We tested registration accuracy by tracking the endoscope’s 6-degree-of-freedom coordinates frame-to-frame in a video recorded as it moved through the phantom, and using these coordinates to measure CT-space positions of markers visible in the final frame. To track the endoscope we used the Nelder-Mead method to search for coordinates that render the virtual frame most similar to the next recorded frame. We measured the endoscope’s initial-frame coordinates using a set of visible markers, and for image similarity we used a combination of mutual information and gradient alignment. CT-space marker positions were measured by projecting their final-frame pixel addresses through the virtual endoscope to intersect with the mesh. Registration error was quantified as the distance between this intersection and the marker’s manually-selected CT-space position. Results: Tracking succeeded for 6 of 8 videos, for which the mean registration error was 4.8±3.5mm (24 measurements total). The mean error in the axial direction (3.1±3.3mm) was larger than in the sagittal or coronal directions (2.0±2.3mm, 1.7±1.6mm). In the other 2 videos, the virtual endoscope got stuck in a false minimum. Conclusion: Our method can successfully track the position and orientation of an endoscope, and it provides accurate spatial mapping from endoscopic video to CT. This method will serve as a foundation for an endoscopy-CT registration

  16. WE-AB-BRA-12: Virtual Endoscope Tracking for Endoscopy-CT Image Registration

    Energy Technology Data Exchange (ETDEWEB)

    Ingram, W; Rao, A; Wendt, R; Court, L [The University of Texas MD Anderson Cancer Center, Houston, TX (United States); The University of Texas Graduate School of Biomedical Sciences, Houston, TX (United States); Yang, J; Beadle, B [The University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: The use of endoscopy in radiotherapy will remain limited until we can register endoscopic video to CT using standard clinical equipment. In this phantom study we tested a registration method using virtual endoscopy to measure CT-space positions from endoscopic video. Methods: Our phantom is a contorted clay cylinder with 2-mm-diameter markers in the luminal surface. These markers are visible on both CT and endoscopic video. Virtual endoscope images were rendered from a polygonal mesh created by segmenting the phantom’s luminal surface on CT. We tested registration accuracy by tracking the endoscope’s 6-degree-of-freedom coordinates frame-to-frame in a video recorded as it moved through the phantom, and using these coordinates to measure CT-space positions of markers visible in the final frame. To track the endoscope we used the Nelder-Mead method to search for coordinates that render the virtual frame most similar to the next recorded frame. We measured the endoscope’s initial-frame coordinates using a set of visible markers, and for image similarity we used a combination of mutual information and gradient alignment. CT-space marker positions were measured by projecting their final-frame pixel addresses through the virtual endoscope to intersect with the mesh. Registration error was quantified as the distance between this intersection and the marker’s manually-selected CT-space position. Results: Tracking succeeded for 6 of 8 videos, for which the mean registration error was 4.8±3.5mm (24 measurements total). The mean error in the axial direction (3.1±3.3mm) was larger than in the sagittal or coronal directions (2.0±2.3mm, 1.7±1.6mm). In the other 2 videos, the virtual endoscope got stuck in a false minimum. Conclusion: Our method can successfully track the position and orientation of an endoscope, and it provides accurate spatial mapping from endoscopic video to CT. This method will serve as a foundation for an endoscopy-CT registration

  17. Excitation-scanning hyperspectral imaging system for microscopic and endoscopic applications

    Science.gov (United States)

    Mayes, Sam A.; Leavesley, Silas J.; Rich, Thomas C.

    2016-04-01

    Current microscopic and endoscopic technologies for cancer screening utilize white-light illumination sources. Hyper-spectral imaging has been shown to improve sensitivity while retaining specificity when compared to white-light imaging in both microscopy and in vivo imaging. However, hyperspectral imaging methods have historically suffered from slow acquisition times due to the narrow bandwidth of spectral filters. Often minutes are required to gather a full image stack. We have developed a novel approach called excitation-scanning hyperspectral imaging that provides 2-3 orders of magnitude increased signal strength. This reduces acquisition times significantly, allowing for live video acquisition. Here, we describe a preliminary prototype excitation-scanning hyperspectral imaging system that can be coupled with endoscopes or microscopes for hyperspectral imaging of tissues and cells. Our system is comprised of three subsystems: illumination, transmission, and imaging. The illumination subsystem employs light-emitting diode arrays to illuminate at different wavelengths. The transmission subsystem utilizes a unique geometry of optics and a liquid light guide. Software controls allow us to interface with and control the subsystems and components. Digital and analog signals are used to coordinate wavelength intensity, cycling and camera triggering. Testing of the system shows it can cycle 16 wavelengths at as fast as 1 ms per cycle. Additionally, more than 18% of the light transmits through the system. Our setup should allow for hyperspectral imaging of tissue and cells in real time.

  18. Fundus autofluorescence and colour fundus imaging compared during telemedicine screening in patients with diabetes.

    Science.gov (United States)

    Kolomeyer, Anton M; Baumrind, Benjamin R; Szirth, Bernard C; Shahid, Khadija; Khouri, Albert S

    2013-06-01

    We investigated the use of fundus autofluorescence (FAF) imaging in screening the eyes of patients with diabetes. Images were obtained from 50 patients with type 2 diabetes undergoing telemedicine screening with colour fundus imaging. The colour and FAF images were obtained with a 15.1 megapixel non-mydriatic retinal camera. Colour and FAF images were compared for pathology seen in nonproliferative and proliferative diabetic retinopathy (NPDR and PDR, respectively). A qualitative assessment was made of the ease of detecting early retinopathy changes and the extent of existing retinopathy. The mean age of the patients was 47 years, most were male (82%) and most were African American (68%). Their mean visual acuity was 20/45 and their mean intraocular pressure was 14.3 mm Hg. Thirty-eight eyes (76%) did not show any diabetic retinopathy changes on colour or FAF imaging. Seven patients (14%) met the criteria for NPDR and five (10%) for severe NPDR or PDR. The most common findings were microaneurysms, hard exudates and intra-retinal haemorrhages (IRH) (n = 6 for each). IRH, microaneurysms and chorioretinal scars were more easily visible on FAF images. Hard exudates, pre-retinal haemorrhage and fibrosis, macular oedema and Hollenhorst plaque were easier to identify on colour photographs. The value of FAF imaging as a complementary technique to colour fundus imaging in detecting diabetic retinopathy during ocular screening warrants further investigation.

  19. Autofluorescence imaging can identify preinvasive or clinically occult lesions in fallopian tube epithelium: a promising step towards screening and early detection.

    Science.gov (United States)

    McAlpine, J N; El Hallani, S; Lam, S F; Kalloger, S E; Luk, M; Huntsman, D G; MacAulay, C; Gilks, C B; Miller, D M; Lane, P M

    2011-03-01

    Optical imaging systems are robust, portable, relatively inexpensive, and have proven utility in detecting precancerous lesions in the lung, esophagus, colon, oral cavity and cervix. We describe the use of light-induced endogenous fluorescence (autofluorescence) in identifying preinvasive and occult carcinomas in ex vivo samples of human fallopian tube (FT) epithelium. Women undergoing surgery for an i) ovarian mass, ii) a history suggestive of hereditary breast-ovarian cancer, or iii) known serous ovarian cancer following neoadjuvant chemotherapy (NAC) were approached for informed consent. Immediately following surgery, FT's were photographed in reflectance and fluorescence at high resolution. Images included: (1) white-light reflectance of luminal/epithelial surface; (2) narrow-band green reflectance (570 nm) (3) green autofluorescence (405/436 nm excitation); and (4) blue autofluorescence (405 nm excitation). Areas revealing a loss of natural tissue fluorescence or marked increase in tissue microvasculature were recorded and compared to final histopathologic diagnosis (SEE-FIM protocol). Fifty-six cases involving one or both fallopian tubes underwent reflectance and fluorescence visualization. Nine cases were excluded, either secondary to non-ovarian primary pathology (7) or excessive trauma (2) rendering tissue interpretation impossible. Of the 47 cases remaining, there were 11 high grade serous (HGS) and 9 non-serous ovarian carcinomas undergoing primary debulking surgery, 5 serous carcinomas having received NAC, 8 benign ovarian tumors, and 14 women undergoing risk-reducing bilateral salpingo-oophorectomy (RRBSO). Methodology was feasible, efficient, and reproducible. TIC or carcinoma was identified in 7/11 HGS, 3/5 NAC, and 1/14 RRBSO. Optical images were reviewed to determine test positive or negative based on standardized criteria. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for the entire

  20. Autofluorescence Lifetimes in Patients With Choroideremia Identify Photoreceptors in Areas With Retinal Pigment Epithelium Atrophy.

    Science.gov (United States)

    Dysli, Chantal; Wolf, Sebastian; Tran, Hoai Viet; Zinkernagel, Martin S

    2016-12-01

    The purpose of this study was to investigate fundus autofluorescence lifetimes in patients with choroideremia and to identify tissue-specific lifetime characteristics and potential prognostic markers. Autofluorescence lifetimes of the retina were measured in two spectral channels (498-560 nm and 560-720 nm) in patients with choroideremia and age-matched healthy controls. Furthermore, autofluorescence intensities and spectral-domain optical coherence tomography (OCT) data were acquired and compared to fundus autofluorescence lifetime data. Sixteen eyes from 8 patients with advanced choroideremia (mean ± SD age, 55 ± 13 years) were included in this study and compared with 10 age-matched healthy participants. Whereas fundus autofluorescence intensity measurement identified areas of remaining retinal pigment epithelium (RPE), autofluorescence lifetime maps identified areas with remaining photoreceptor layers in OCT but RPE atrophy. In these areas, mean (±SEM) lifetimes were 567 ± 59 ps in the short and 603 ± 49 ps in the long spectral channels (+98% and +88% compared to controls). In areas of combined RPE atrophy and loss of photoreceptors, autofluorescence lifetimes were significantly prolonged by 1116 ± 63 ps (+364%) in the short and by 915 ± 52 ps (+270%) in the long spectral channels compared with controls. Because autofluorescence lifetimes identify areas of remaining photoreceptors in the absence of RPE, this imaging modality may be useful to monitor disease progression in the natural course of disease and in context of potential future therapeutic interventions.

  1. Autofluorescence spectroscopy and imaging: a tool for biomedical research and diagnosis

    Directory of Open Access Journals (Sweden)

    A.C. Croce

    2014-10-01

    Full Text Available Native fluorescence, or autofluorescence (AF, consists in the emission of light in the UV-visible, near-IR spectral range when biological substrates are excited with light at suitable wavelength. This is a well-known phenomenon, and the strict relationship of many endogenous fluorophores with morphofunctional properties of the living systems, influencing their AF emission features, offers an extremely powerful resource for directly monitoring the biological substrate condition. Starting from the last century, the technological progresses in microscopy and spectrofluorometry were convoying attention of the scientific community to this phenomenon. In the future, the interest in the autofluorescence will certainly continue. Current instrumentation and analytical procedures will likely be overcome by the unceasing progress in new devices for AF detection and data interpretation, while a progress is expected in the search and characterization of endogenous fluorophores and their roles as intrinsic biomarkers.

  2. Fundus autofluorescence in retinal artery occlusion: A more precise diagnosis.

    Science.gov (United States)

    Bacquet, J-L; Sarov-Rivière, M; Denier, C; Querques, G; Riou, B; Bonin, L; Barreau, E; Labetoulle, M; Rousseau, A

    2017-10-01

    Retinal artery occlusion (RAO) is a medical emergency associated with a high risk of cerebral vascular accident and other cardiovascular events. Among patients with non-arteritic RAO, a retinal embolus is observed in approximately 40% of cases. Fundus examination and retinography are not reliable to predict the nature of the emboli. We report three consecutive cases of central and branch RAO that were investigated with fundus autofluorescence, fluorescein angiography and color retinal photographs. All patients underwent complete neurological and cardiovascular workups, with brain imaging, cardiac Doppler ultrasound, carotid Dopplers and Holter ECG's, to determine the underlying mechanism of retinal embolism. In the three cases, aged 77.7±4 years (2 women and 1 man), fundus autofluorescence demonstrated hyperautofluorescent emboli. In two cases, it allowed visualization of emboli that were not detected with fundus examination or retinography. The cardiovascular work-up demonstrated atheromatous carotid or aortic plaques in all patients. In one case, it permitted the diagnosis of RAO. Two of the three cases were considered to be of atherosclerotic origin and one of undefined origin. Fundus autofluorescence may help to detect and characterize retinal emboli. Since lipofuscin, which is present in large quantity in atherosclerotic plaques, is the main fluorophore detected with fundus autofluorescence, this non-invasive and simple examination may give information about the underlying mechanism of retinal embolism, and thus impact the etiologic assessment of RAO. Additional studies are necessary to confirm this potential role of autofluorescence. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  3. Fundus Autofluorescence Captured With a Nonmydriatic Retinal Camera in Vegetarians Versus Nonvegetarians.

    Science.gov (United States)

    Kommana, Sumana S; Padgaonkar, Pooja; Mendez, Nicole; Wu, Lesley; Szirth, Bernard; Khouri, Albert S

    2015-09-09

    A baseline level of lipofuscin in the retinal pigment epithelium (RPE) is inevitable with age, but increased levels due to increased oxidative stress can result in deleterious vision loss at older ages. As earlier detection of differences in levels can lead to superior preventative management, we studied the relationship between lipofuscin accumulation and dietary lifestyle (vegetarian vs. nonvegetarian) in the younger, healthy South Asian population using retinal fundus autofluorescence (FAF) imaging. In this pilot study, we examined 37 healthy subjects (average age 23 years ± 1) all undergoing similar stress levels as medical students at Rutgers New Jersey Medical School. Levels of lipofuscin concentrations were imaged using a FAF retinal camera (Canon CX-1). Two images (color and FAF) were captured of the left eye and included in the analysis. FAF quantitative scoring was measured in 2 regions of the captured image, the papillo-macular region (P) and the macula (M), by determining the grayscale score of a 35.5 mm(2) rectangle in the respective regions. Standardized scores (corrected to remove baseline fluorescence) were then obtained. Means, standard deviations, and t tests were performed for comparisons. Fundus autofluorescence scores of regions P and M were significantly different (P vegetarians had statistically significant lower levels of autofluorescence. These findings can have potential implications regarding long-term retinal health and risk for developing certain diseases over decades in subjects at risk for vision-threatening diseases. © 2015 Diabetes Technology Society.

  4. Hyperspectral imaging of colonic polyps in vivo (Conference Presentation)

    Science.gov (United States)

    Clancy, Neil T.; Elson, Daniel S.; Teare, Julian

    2017-02-01

    Standard endoscopic tools restrict clinicians to making subjective visual assessments of lesions detected in the bowel, with classification results depending strongly on experience level and training. Histological examination of resected tissue remains the diagnostic gold standard, meaning that all detected lesions are routinely removed. This subjects the patient to risk of polypectomy-related injury, and places significant workload and economic burdens on the hospital. An objective endoscopic classification method would allow hyperplastic polyps, with no malignant potential, to be left in situ, or low grade adenomas to be resected and discarded without histology. A miniature multimodal flexible endoscope is proposed to obtain hyperspectral reflectance and dual excitation autofluorescence information from polyps in vivo. This is placed inside the working channel of a conventional colonoscope, with the external scanning and detection optics on a bedside trolley. A blue and violet laser diode pair excite endogenous fluorophores in the respiration chain, while the colonoscope's xenon light source provides broadband white light for diffuse reflectance measurements. A push-broom HSI scanner collects the hypercube. System characterisation experiments are presented, defining resolution limits as well as acquisition settings for optimal spectral, spatial and temporal performance. The first in vivo results in human subjects are presented, demonstrating the clinical utility of the device. The optical properties (reflectance and autofluorescence) of imaged polyps are quantified and compared to the histologically-confirmed tissue type as well as the clinician's visual assessment. Further clinical studies will allow construction of a full robust training dataset for development of classification schemes.

  5. Fundus Autofluorescence in Multiple Evanescent White Dot Syndrome

    Directory of Open Access Journals (Sweden)

    Fernando Marcondes Penha

    2011-01-01

    Full Text Available A patient complained of photopsia and vision loss in the left eye for two days, with visual acuity of 20/32. Right eye was normal. Funduscopy revealed foveal granularity and gray-white lesions in the posterior pole, mainly temporal to the fovea. The lesions (dots and spots, along with a few other areas surrounding them, showed hyperautofluorescence on autofluorescence imaging. Fluorescein angiogram (FA depicted some early hyperfluorescent dots with late staining. Indocyanine green angiogram (ICGA showed hypofluorescent lesions in a greater number compared with funduscopy, autofluorescence, and FA. Thirty days later, BCVA was 20/20 in both eyes and the complimentary exams were almost normal, despite an ICGA that showed few small hypofluorescent lesions. This case supports the hypothesis that the choroidal involvement occurs primarily in MEWDS, with secondary involvement of the RPE and the neurosensory retina.

  6. Autofluorescence imaging endoscopy can distinguish non-erosive reflux disease from functional heartburn: A pilot study.

    Science.gov (United States)

    Luo, Xi; Guo, Xiao-Xu; Wang, Wei-Feng; Peng, Li-Hua; Yang, Yun-Sheng; Uedo, Noriya

    2016-04-14

    To investigate whether autofluorescence imaging (AFI) endoscopy can distinguish non-erosive reflux disease (NERD) from functional heartburn (FH). In this prospective observational trial, 127 patients presenting with typical reflux symptoms for > 6 mo were screened. All the participants underwent endoscopy, during which white light imaging (WLI) was followed by AFI. Finally 84 patients with normal esophageal appearance on WLI were enrolled. It was defined as being suggestive of NERD if one or more longitudinal purple lines longer than one centimeter were visualized in the distal part of the esophagus during AFI endoscopy. Ambulatory 24-h multichannel intraluminal impedance and pH monitoring was also performed. After standard proton-pump inhibitor (PPI) tests, subjects were divided into an NERD group and an FH group and the diagnostic performance of AFI endoscopy to differentiate NERD from FH was evaluated. Of 84 endoscopy-negative patients, 36 (42.9%) had a normal pH/impedance test. Of these, 26 patients with favorable responses to PPI tests were classified as having NERD. Finally 10 patients were diagnosed with FH and the others with NERD. Altogether, 68 (81.0%) of the 84 patients were positive on AFI endoscopy. In the NERD group, there were 67 (90.5%) patients with abnormal esophageal findings on AFI endoscopy while only 1 (10%) patient was positive on AFI endoscopy in the FH group. The sensitivity and specificity of AFI in differentiating NERD from FH were 90.5% (95%CI: 81.5%-96.1%) and 90.0% (95%CI: 55.5%-99.7%), respectively. Meanwhile, the accuracy, positive predictive value and negative predictive value of AFI in differentiating between NERD and FH were 90.5% (95%CI: 84.2%-96.8%), 98.5% (95%CI: 92.1%-99.9%) and 56.3% (95%CI: 30.0%-80.2%), respectively. Autofluorescence imaging may serve as a complementary method in evaluating patients with NERD and FH.

  7. Flow mapping of multiphase flows using a novel single stem endoscopic particle image velocimetry instrument

    International Nuclear Information System (INIS)

    Lad, N; Adebayo, D; Aroussi, A

    2011-01-01

    Particle image velocimetry (PIV) is a successful flow mapping technique which can optically quantify large portions of a flow regime. This enables the method to be completely non-intrusive. The ability to be non-intrusive to any flow has allowed PIV to be used in a large range of industrial sectors for many applications. However, a fundamental disadvantage of the conventional PIV technique is that it cannot easily be used with flows which have no or limited optical access. Flows which have limited optical access for PIV measurement have been addressed using endoscopic PIV techniques. This system uses two separate probes which relay a light sheet and imaging optics to a planar position within the desired flow regime. This system is effective in medical and engineering applications. The present study has been involved in the development of a new endoscopic PIV system which integrates the illumination and imaging optics into one rigid probe. This paper focuses on the validation of the images taken from the novel single stem endoscopic PIV system. The probe is used within atomized spray flow and is compared with conventional PIV measurement and also pitot-static data. The endoscopic PIV system provides images which create localized velocity maps that are comparable with the global measurement of the conventional PIV system. The velocity information for both systems clearly show similar results for the spray characterization and are also validated using the pitot-static data

  8. Simple fibre based dispersion management for two-photon excited fluorescence imaging through an endoscope

    DEFF Research Database (Denmark)

    Dimopoulos, Konstantinos; Marti, Dominik; Andersen, Peter E.

    2018-01-01

    We want to implement two-photon excitation fluorescence microscopy (TPEFM) into endoscopes, since TPEFM can provide relevant biomarkers for cancer staging and grading in hollow organs, endoscopically accessible through natural orifices. However, many obstacles must be overcome, among others...... the delivery of short laser pulses to the distal end of the endoscope. To this avail, we present imaging results using an all-fibre dispersion management scheme in a TPEFM setup. The scheme has been conceived by Jespersen et al. in 20101 and relies on the combination of a single mode fibre with normal...

  9. On the autofluorescence of aged fingermarks

    NARCIS (Netherlands)

    van Dam, Annemieke; Aalders, Maurice C. G.; Todorovski, Toni; van Leeuwen, Ton G.; Lambrechts, Saskia A. G.

    2016-01-01

    Fingermark autofluorescence changes with time, both spectrally and in total intensity. In this study we investigate which components in the aged fingermarks cause this change in autofluorescent signal. Thin layer chromatography combined with fluorescence spectroscopy was used to identify fluorescent

  10. Endoscopes with latest technology and concept.

    Science.gov (United States)

    Gotoh

    2003-09-01

    Endoscopic imaging systems that perform as the "eye" of the operator during endoscopic surgical procedures have developed rapidly due to various technological developments. In addition, since the most recent turn of the century robotic surgery has increased its scope through the utilization of systems such as Intuitive Surgical's da Vinci System. To optimize the imaging required for precise robotic surgery, a unique endoscope has been developed, consisting of both a two dimensional (2D) image optical system for wider observation of the entire surgical field, and a three dimensional (3D) image optical system for observation of the more precise details at the operative site. Additionally, a "near infrared radiation" endoscopic system is under development to detect the sentinel lymph node more readily. Such progress in the area of endoscopic imaging is expected to enhance the surgical procedure from both the patient's and the surgeon's point of view.

  11. Laser scanning endoscope via an imaging fiber bundle for fluorescence imaging

    Science.gov (United States)

    Yeboah, Lorenz D.; Nestler, Dirk; Steiner, Rudolf W.

    1994-12-01

    Based on a laser scanning endoscope via an imaging fiber bundle, a new approach for a tumor diagnostic system has been developed to assist physicians in the diagnosis before the actual PDT is carried out. Laser induced, spatially resolved fluorescence images of diseased tissue can be compared with images received by video endoscopy using a white light source. The set- up is required to produce a better contrast between infected and healthy tissue and might serve as a constructive diagnostic help for surgeons. The fundamental idea is to scan a low-power laser beam on an imaging fiber bundle and to achieve a spatially resolved projection on the tissue surface. A sufficiently high laser intensity from the diode laser is concentrated on each single spot of the tissue exciting fluorescence when a dye has previously been accumulated. Subsequently, video image of the tissue is recorded and stored. With an image processing unit, video and fluorescence images are overlaid producing a picture of the fluorescence intensity in the environment of the observed tissue.

  12. Chromaticity based smoke removal in endoscopic images

    Science.gov (United States)

    Tchaka, Kevin; Pawar, Vijay M.; Stoyanov, Danail

    2017-02-01

    In minimally invasive surgery, image quality is a critical pre-requisite to ensure a surgeons ability to perform a procedure. In endoscopic procedures, image quality can deteriorate for a number of reasons such as fogging due to the temperature gradient after intra-corporeal insertion, lack of focus and due to smoke generated when using electro-cautery to dissect tissues without bleeding. In this paper we investigate the use of vision processing techniques to remove surgical smoke and improve the clarity of the image. We model the image formation process by introducing a haze medium to account for the degradation of visibility. For simplicity and computational efficiency we use an adapted dark-channel prior method combined with histogram equalization to remove smoke artifacts to recover the radiance image and enhance the contrast and brightness of the final result. Our initial results on images from robotic assisted procedures are promising and show that the proposed approach may be used to enhance image quality during surgery without additional suction devices. In addition, the processing pipeline may be used as an important part of a robust surgical vision pipeline that can continue working in the presence of smoke.

  13. Polymer Optical Fibre Sensors for Endoscopic Opto-Acoustic Imaging

    DEFF Research Database (Denmark)

    Broadway, Christian; Gallego, Daniel; Woyessa, Getinet

    2015-01-01

    in existing publications. A great advantage can be obtained for endoscopy due to a small size and array potential to provide discrete imaging speed improvements. Optical fibre exhibits numerous advantages over conventional piezo-electric transducers, such as immunity from electromagnetic interference...... is the physical size of the device, allowing compatibility with current technology, while governing flexibility of the distal end of the endoscope based on the needs of the sensor. Polymer optical fibre (POF) presents a novel approach for endoscopic applications and has been positively discussed and compared...... and a higher resolution at small sizes. Furthermore, micro structured polymer optical fibres offer over 12 times the sensitivity of silica fibre. We present a polymer fibre Bragg grating ultrasound detector with a core diameter of 125 microns. We discuss the ultrasonic signals received and draw conclusions...

  14. Pancreas imaging by computed tomography after endoscopic retrograde pancreatography

    International Nuclear Information System (INIS)

    Frick, M.P.; O'Leary, J.F.; Salomonowitz, E.; Stoltenberg, E.; Hutton, S.; Gedgaudas, E.

    1984-01-01

    A method using CT after endoscopic retrograde pancreatography (CT-ERP) is described for pancreatic imaging. When using an ERP technique in the canine model comparable to that used in humans, small amounts of contrast material in peripheral pancreatic radicles resulted in enhancement of the pancreas on CT scans. Nine patients were also studied by CT-ERP images. The main pancreatic duct was seen on delayed images. In cases of chronic pancreatitis (n = 2), pancreatic opacification was patchy and heterogeneous. There was no contrast-material enhancement in areas of pancreatic carcimomas (n = 2). CT-ERP showed the true extent of carcinoma better than ERP alone

  15. A standardized imaging protocol for the endoscopic prediction of dysplasia within sessile serrated polyps (with video).

    Science.gov (United States)

    Tate, David J; Jayanna, Mahesh; Awadie, Halim; Desomer, Lobke; Lee, Ralph; Heitman, Steven J; Sidhu, Mayenaaz; Goodrick, Kathleen; Burgess, Nicholas G; Mahajan, Hema; McLeod, Duncan; Bourke, Michael J

    2018-01-01

    Dysplasia within sessile serrated polyps (SSPs) is difficult to detect and may be mistaken for an adenoma, risking incomplete resection of the background serrated tissue, and is strongly implicated in interval cancer after colonoscopy. The use of endoscopic imaging to detect dysplasia within SSPs has not been systematically studied. Consecutively detected SSPs ≥8 mm in size were evaluated by using a standardized imaging protocol at a tertiary-care endoscopy center over 3 years. Lesions suspected as SSPs were analyzed with high-definition white light then narrow-band imaging. A demarcated area with a neoplastic pit pattern (Kudo type III/IV, NICE type II) was sought among the serrated tissue. If this was detected, the lesion was labeled dysplastic (sessile serrated polyp with dysplasia); if not, it was labeled non-dysplastic (sessile serrated polyp without dysplasia). Histopathology was reviewed by 2 blinded specialist GI pathologists. A total of 141 SSPs were assessed in 83 patients. Median lesion size was 15.0 mm (interquartile range 10-20), and 54.6% were in the right side of the colon. Endoscopic evidence of dysplasia was detected in 36 of 141 (25.5%) SSPs; of these, 5 of 36 (13.9%) lacked dysplasia at histopathology. Two of 105 (1.9%) endoscopically designated non-dysplastic SSPs had dysplasia at histopathology. Endoscopic imaging, therefore, had an accuracy of 95.0% (95% confidence interval [CI], 90.1%-97.6%) and a negative predictive value of 98.1% (95% CI, 92.6%-99.7%) for detection of dysplasia within SSPs. Dysplasia within SSPs can be detected accurately by using a simple, broadly applicable endoscopic imaging protocol that allows complete resection. Independent validation of this protocol and its dissemination to the wider endoscopic community may have a significant impact on rates of interval cancer. (Clinical trial registration number: NCT03100552.). Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All

  16. Macular autofluorescence in eyes with cystoid macula edema, detected with 488 nm-excitation but not with 580 nm-excitation.

    Science.gov (United States)

    Bessho, Kenichiro; Gomi, Fumi; Harino, Seiyo; Sawa, Miki; Sayanagi, Kaori; Tsujikawa, Motokazu; Tano, Yasuo

    2009-06-01

    Fundus autofluorescence (AF) derives from lipofuscin in the retinal pigment epithelium (RPE). Because lipofuscin is a by-product of phagocytosis of photoreceptors by RPE, AF imaging is expected to describe some functional aspect of the retina. In this study we report distribution of AF in patients showing macular edema. Three eyes with diabetic macular edema (DME) and 11 with retinal vein occlusion (RVO), associated with macular edema (ME) were examined. ME was determined by standard fundus examination, fluorescein angiography (FA) and optical coherence tomography (OCT). AF was recorded using a Heidelberg confocal scanning laser ophthalmoscope (cSLO) with 488 nm laser exciter (488 nm-AF), and a conventional Topcon fundus camera with halogen lamp exciter and 580 nm band-pass filter (580 nm-AF). Color fundus picture, FA image and these two AF images were analyzed by superimposing all images. All subjects presented cystoid macular edema (CME) with petaloid pattern hyperfluorescence in FA. In 488 nm-AF, all eyes (100%) showed macular autofluorescence of a similar shape to that of the CME in FA. In contrast, in 580 nm-AF only one eye (7%) presented this corresponding petaloid-shaped autofluorescence. In all cases, peripheral retinal edemas did not show autofluorescence corresponding to the leakage in FA. In eyes with CME, analogous hyperautofluorescence to the CME was always observed in 488 nm-AF, while it was rarely observed in 580 nm-AF. Moreover, this CME hyperautofluorescence was only seen in the macular area. We hypothesize that autofluorescence from CME may be considered as a "pseudo" or "relative" autofluorescence, due to macular stretching following CME that may result in lateral displacement of macular pigments (MPs) and subsequent reduction of MPs density, as MPs block 488 nm-AF more intensely than 580 nm-AF. Although this phenomenon may not directly indicate change of RPE function, it may be used as a method to assess or track CME non-invasively.

  17. Eyewear-style three-dimensional endoscope derived from microstructured polymer fiber with the function of image transmission

    International Nuclear Information System (INIS)

    Kong De-Peng; Wang Li-Li; He Zheng-Quan; Ma Tian; Chu Jiu-Rong

    2013-01-01

    A method of fabricating multi-core polymer image fiber is proposed. Image fiber preform is fabricated by stacking thousands of polymer fibers each with a 0.25-mm diameter orderly in a die by only one step. The preform is heated and stretched into image fiber with an outer diameter of 2 mm. Then a portable eyewear-style three-dimensional (3D) endoscope system is designed, fabricated, and characterized. This endoscopic system is composed of two graded index lenses, two pieces of 0.35-m length image guide fibers, and a pair of oculars. It shows good flexibility and portability, and can provide the depth information accordingly. (general)

  18. Integrated endoscopic OCT system and in-vivo images of human internal organs

    Science.gov (United States)

    Sergeev, Alexander M.; Gelikonov, Valentin M.; Gelikonov, Grigory V.; Feldchtein, Felix I.; Kuranov, Roman V.; Gladkova, Natalia D.; Shakhova, Natalia M.; Snopova, Ludmila; Shakhov, Andrei; Kuznetzova, Irina N.; Denisenko, Arkady; Pochinko, Vitaly; Chumakov, Yuri; Almasov, Valentin

    1998-04-01

    First results of endoscopic applications of optical coherence tomography (OCT) for in vivo studies of human mucosa in respiratory, gastrointestinal, urinary and genital tracts are presented. A novel endoscopic OCT (EOCT) system has been created that is based on the integration of a sampling arm of an all-optical-fiber interferometer into standard endoscopic devices using their biopsy channel to transmit low-coherence radiation to investigated tissue. We have studied mucous membranes of esophagus, larynx, stomach, urinary bladder, uterine cervix and endometrium as typical localization for carcinomatous processes. Images of tumor tissues versus healthy tissues have been recorded and analyzed. Violations of well-defined stratified healthy mucosa structure in cancered tissue is distinctly seen by EOCT, thus making this technique promising for early diagnosis of tumors and precise guiding of excisional biopsy.

  19. Serial imaging and structure-function correlates of high-density rings of fundus autofluorescence in retinitis pigmentosa.

    Science.gov (United States)

    Robson, Anthony G; Tufail, Adnan; Fitzke, Fred; Bird, Alan C; Moore, Anthony T; Holder, Graham E; Webster, Andrew R

    2011-09-01

    To document the evolution and functional and structural significance of parafoveal rings of high-density fundus autofluorescence (AF) in patients with retinitis pigmentosa and preserved visual acuity. Fifty-two patients with nonsyndromic retinitis pigmentosa or Usher syndrome, who had a parafoveal ring of high-density AF and a visual acuity of 20/30 or better, were ascertained. All had international standard full-field electroretinography and pattern electroretinography. Autofluorescence imaging was repeated in 30 patients after periods of up to 9.3 years. Of the 52 patients, 35 underwent optical coherence tomography. Progressive constriction of the ring was detected in 17 patients. Ring radius reduced by up to 40% at a mean rate of between 0.8% and 15.8% per year. In 1 patient, a small ring was replaced by irregular AF; visual acuity deteriorated over the same period. There was a high correspondence between the lateral extent of the preserved optical coherence tomography inner segment/outer segment band and the diameter of the ring along the same optical coherence tomographic scan plane (slope, 0.9; r = 0.97; P retina and preserved photopic function. Serial fundus AF may provide prognostic indicators for preservation of central acuity and potentially assist in the identification and evaluation of patients suitable for treatment aimed at preservation of remaining function.

  20. SU-C-18A-02: Image-Based Camera Tracking: Towards Registration of Endoscopic Video to CT

    International Nuclear Information System (INIS)

    Ingram, S; Rao, A; Wendt, R; Castillo, R; Court, L; Yang, J; Beadle, B

    2014-01-01

    Purpose: Endoscopic examinations are routinely performed on head and neck and esophageal cancer patients. However, these images are underutilized for radiation therapy because there is currently no way to register them to a CT of the patient. The purpose of this work is to develop a method to track the motion of an endoscope within a structure using images from standard clinical equipment. This method will be incorporated into a broader endoscopy/CT registration framework. Methods: We developed a software algorithm to track the motion of an endoscope within an arbitrary structure. We computed frame-to-frame rotation and translation of the camera by tracking surface points across the video sequence and utilizing two-camera epipolar geometry. The resulting 3D camera path was used to recover the surrounding structure via triangulation methods. We tested this algorithm on a rigid cylindrical phantom with a pattern spray-painted on the inside. We did not constrain the motion of the endoscope while recording, and we did not constrain our measurements using the known structure of the phantom. Results: Our software algorithm can successfully track the general motion of the endoscope as it moves through the phantom. However, our preliminary data do not show a high degree of accuracy in the triangulation of 3D point locations. More rigorous data will be presented at the annual meeting. Conclusion: Image-based camera tracking is a promising method for endoscopy/CT image registration, and it requires only standard clinical equipment. It is one of two major components needed to achieve endoscopy/CT registration, the second of which is tying the camera path to absolute patient geometry. In addition to this second component, future work will focus on validating our camera tracking algorithm in the presence of clinical imaging features such as patient motion, erratic camera motion, and dynamic scene illumination

  1. Low auto-fluorescence fabrication methods for plastic nanoslits.

    Science.gov (United States)

    Yin, Zhifu; Qi, Liping; Zou, Helin; Sun, Lei; Xu, Shenbo

    2016-04-01

    Plastic nanofluidic devices are becoming increasingly important for biological and chemical applications. However, they suffer from high auto-fluorescence when used for on-chip optical detection. In this study, the auto-fluorescence problem of plastic nanofluidic devices was remedied by newly developed fabrication methods that minimise their auto-fluorescence: one by depositing a gold (Au) layer on them, the other by making them ultra-thin. In the first method, the Au layer [minimum thickness is 40 nm on 150 μm SU-8, 50 nm on 1 mm polyethylene terephthalate (PET), and 40 on 2 nm polymethyl methacrylate (PMMA)] blocks the auto-fluorescence of the polymer; in the second method, auto-fluorescence is minimised by making the chips ultra-thin, selected operating thickness of SU-8 is 20 μm, for PET it is 150 μm, and for PMMA it is 0.8 mm.

  2. Augmented Endoscopic Images Overlaying Shape Changes in Bone Cutting Procedures.

    Science.gov (United States)

    Nakao, Megumi; Endo, Shota; Nakao, Shinichi; Yoshida, Munehito; Matsuda, Tetsuya

    2016-01-01

    In microendoscopic discectomy for spinal disorders, bone cutting procedures are performed in tight spaces while observing a small portion of the target structures. Although optical tracking systems are able to measure the tip of the surgical tool during surgery, the poor shape information available during surgery makes accurate cutting difficult, even if preoperative computed tomography and magnetic resonance images are used for reference. Shape estimation and visualization of the target structures are essential for accurate cutting. However, time-varying shape changes during cutting procedures are still challenging issues for intraoperative navigation. This paper introduces a concept of endoscopic image augmentation that overlays shape changes to support bone cutting procedures. This framework handles the history of the location of the measured drill tip as a volume label and visualizes the remains to be cut overlaid on the endoscopic image in real time. A cutting experiment was performed with volunteers, and the feasibility of this concept was examined using a clinical navigation system. The efficacy of the cutting aid was evaluated with respect to the shape similarity, total moved distance of a cutting tool, and required cutting time. The results of the experiments showed that cutting performance was significantly improved by the proposed framework.

  3. Automatic classification of minimally invasive instruments based on endoscopic image sequences

    Science.gov (United States)

    Speidel, Stefanie; Benzko, Julia; Krappe, Sebastian; Sudra, Gunther; Azad, Pedram; Müller-Stich, Beat Peter; Gutt, Carsten; Dillmann, Rüdiger

    2009-02-01

    Minimally invasive surgery is nowadays a frequently applied technique and can be regarded as a major breakthrough in surgery. The surgeon has to adopt special operation-techniques and deal with difficulties like the complex hand-eye coordination and restricted mobility. To alleviate these constraints we propose to enhance the surgeon's capabilities by providing a context-aware assistance using augmented reality techniques. To analyze the current situation for context-aware assistance, we need intraoperatively gained sensor data and a model of the intervention. A situation consists of information about the performed activity, the used instruments, the surgical objects, the anatomical structures and defines the state of an intervention for a given moment in time. The endoscopic images provide a rich source of information which can be used for an image-based analysis. Different visual cues are observed in order to perform an image-based analysis with the objective to gain as much information as possible about the current situation. An important visual cue is the automatic recognition of the instruments which appear in the scene. In this paper we present the classification of minimally invasive instruments using the endoscopic images. The instruments are not modified by markers. The system segments the instruments in the current image and recognizes the instrument type based on three-dimensional instrument models.

  4. Autofluorescence imaging of macular pigment: influence and correction of ocular media opacities

    Science.gov (United States)

    Sharifzadeh, Mohsen; Obana, Akira; Gohto, Yuko; Seto, Takahiko; Gellermann, Werner

    2014-09-01

    The healthy adult human retina contains in its macular region a high concentration of blue-light absorbing carotenoid compounds, known as macular pigment (MP). Consisting of the carotenoids lutein, zeaxanthin, and meso-zeaxanthin, the MP is thought to shield the vulnerable tissue layers in the retina from light-induced damage through its function as an optical attenuator and to protect the tissue cells within its immediate vicinity through its function as a potent antioxidant. Autofluorescence imaging (AFI) is emerging as a viable optical method for MP screening of large subject populations, for tracking of MP changes over time, and for monitoring MP uptake in response to dietary supplementation. To investigate the influence of ocular media opacities on AFI-based MP measurements, in particular, the influence of lens cataracts, we conducted a clinical trial with a large subject population (93 subjects) measured before and after cataract surgery. General AFI image contrast, retinal blood vessel contrast, and presurgery lens opacity scores [Lens Opacities Classification System III (LOCS III)] were investigated as potential predictors for image degradation. These clinical results show that lens cataracts can severely degrade the achievable pixel contrasts in the AFI images, which results in nominal MP optical density levels that are artifactually reduced. While LOCS III scores and blood vessel contrast are found to be only a weak predictor for this effect, a strong correlation exists between the reduction factor and the image contrast, which can be quantified via pixel intensity histogram parameters. Choosing the base width of the histogram, the presence or absence of ocular media opacities can be determined and, if needed, the nominal MP levels can be corrected with factors depending on the strength of the opacity.

  5. Complementary angiographic and autofluorescence findings in pseudoxanthoma elasticum.

    Science.gov (United States)

    Lee, Thomas K M; Forooghian, Farzin; Cukras, Catherine; Wong, Wai T; Chew, Emily Y; Meyerle, Catherine B

    2010-02-01

    Pseudoxanthoma elasticum (PXE) is a systemic disease with characteristic findings on fundus examination. The fundus findings may be difficult to detect with ophthalmoscopy. A case report is described as follows. A PXE patient had subtle retinal findings on fundoscopy that were more prominently seen using a combination of both fundus autofluorescence (FAF) imaging and indocyanine green (ICG) angiography. The fundus features visualized using each of these two modalities appeared different from each other. FAF imaging and ICG angiography may be able to more prominently detect pathology at the level of the retinal pigment epithelium and Bruch's membrane, respectively. The use of these imaging modalities together may be complementary and useful in the evaluation of patients with PXE.

  6. A comparison of white light laryngostroboscopy versus autofluorescence endoscopy in the evaluation of vocal fold pathology.

    Science.gov (United States)

    Caffier, Philipp P; Schmidt, Bernd; Gross, Manfred; Karnetzky, Klaus; Nawka, Tadeus; Rotter, Andreas; Seipelt, Matthias; Sedlmaier, Benedikt

    2013-07-01

    To prove the diagnostic value of autofluorescence endoscopy (AFE) and white light laryngostroboscopy (WLS) versus the gold standard microlaryngoscopy with histopathological examination in differential diagnostics of laryngeal lesions for experienced phoniatricians and laryngologists, using the PENTAX SAFE-3000 system. Exploratory cohort study. High-resolution rigid WLS was executed in 32 consecutive patients with initial manifestation of benign, precancerous, and malignant vocal fold lesions. Fiberoptic blue light AFE (SAFE-3000; λ = 408 nm) was subsequently performed by an experienced endoscopist in a blinded study setting. Findings were rated based on objective WLS and AFE parameters (e.g., phonatory vibration, mucosal wave propagation, and loss of autofluorescence). The clinically assumed WLS and AFE diagnoses were compared with the final histopathology of biopsied material taken during microlaryngoscopy. In reference to histopathological diagnosis, WLS achieved a higher sensitivity (100% vs. 94%), specificity (94% vs. 69%), and accuracy (97% vs. 81%) than AFE diagnostics. The concordance between both endoscopic techniques was 87.5% (28/32 patients); additional AFE benefits were not detectable. Significant loss of autofluorescence was observed in malignant findings clinically clearly diagnosed by WLS, but also in chronic inflammation, severe dysplasia, granulomas, vascular polyps, and glottal papillomatosis. The evaluation of vocal fold pathology by the clinically experienced examiner precisely applying WLS appears to be more reliable than diagnostics of mucosal tissue changes by means of AFE via the SAFE-3000 system as a relatively nonspecific method. Microlaryngoscopy with histopathological examination and phonomicrosurgical excision of pathologic changes remains the gold standard. © 2012 The American Laryngological, Rhinological and Otological Society, Inc.

  7. Wide-field fundus autofluorescence corresponds to visual fields in chorioretinitis patients

    Directory of Open Access Journals (Sweden)

    Seidensticker F

    2011-11-01

    Full Text Available Florian Seidensticker1, Aljoscha S Neubauer1, Tamer Wasfy1,2, Carmen Stumpf1, Stephan R Thurau1,*, Anselm Kampik1, Marcus Kernt1,*1Department of Ophthalmology, Ludwig-Maximilians-University, Munich, Germany; 2Department of Ophthalmology, Tanta University, Tanta, Egypt *Both authors contributed equally to this workBackground and objectives: Detection of peripheral fundus autofluorescence (FAF using conventional scanning laser ophthalmoscopes (SLOs is difficult and requires pupil dilation. Here we evaluated the diagnostic properties of wide-field FAF detected by a two-laser wavelength wide-field SLO in uveitis patients.Study design/materials and methods: Observational case series of four patients suffering from different types of posterior uveitis/chorioretinitis. Wide-field FAF images were compared to visual fields. Panretinal FAF was detected by a newly developed SLO, which allows FAF imaging of up to 200° of the retina in one scan without the need for pupil dilation. Visual fields were obtained by Goldmann manual perimetry.Results: Findings from wide-field FAF imaging showed correspondence to visual field defects in all cases.Conclusion: Wide-field FAF allowed the detection of visual field defect-related alterations of the retinal pigment epithelium in all four uveitis cases.Keywords: fundus autofluorescence (FAF, Optomap, wide-field scanning laser ophthalmoscopy, imaging, uveitis, visual field

  8. Subretinal drusenoid deposits with increased autofluorescence in eyes with reticular pseudodrusen.

    Science.gov (United States)

    Lee, Mee Yon; Ham, Don-Il

    2014-01-01

    To characterize a variant type of drusenoid deposit with different imaging features in comparison to reticular pseudodrusen. Retrospective observational consecutive case series. Eyes showing atypical drusenoid lesions were sorted out from 257 eyes of 133 patients previously diagnosed as reticular pseudodrusen. Eyes were evaluated using color fundus photography, confocal scanning laser ophthalmoscopy, and spectral domain optical coherence tomography. A variant type of drusenoid deposits showing different imaging features from reticular pseudodrusen was found in 17 eyes of 12 patients (6.6%). The mean age of patients was 62.7 ± 11.6 years, and all patients were women. These deposits were observed as yellowish white, round to oval lesions on color photographs, located under the sensory retina and above the retinal pigment epithelium on spectral domain optical coherence tomography similar to reticular pseudodrusen. However, they were present in a smaller number as discrete lesions and showed increased autofluorescence. None of them were accompanied by late age-related macular degeneration. Subretinal drusenoid deposits are not homogeneous and can be classified into two types according to the fundus autofluorescence. Multimodal imaging tests are needed for the differential diagnosis of subretinal drusenoid deposits.

  9. Autofluorescence from the outer retina and subretinal space: hypothesis and review.

    Science.gov (United States)

    Spaide, Richard

    2008-01-01

    To review the pathophysiologic principles underlying increased autofluorescence from the outer retina and subretinal space using selected diseases as examples. The ocular imaging information and histopathologic features, when known, were integrated for diseases causing increased autofluorescence from the outer retina and subretinal space. Inferences were taken from this information and used to create a classification scheme. These diseases are principally those that cause separation of the outer retina from the retinal pigment epithelium, thereby preventing proper phagocytosis of photoreceptor outer segments. The separation can arise from increased exudation into the subretinal space or inadequate removal of fluid from the subretinal space. Lack of normal outer segment processing initially leads to increased accumulation of outer segments on the outer retina and subretinal space. Over time, this material is visible as an increasingly thick coating on the outer retina, is yellow, and is autofluorescent. Over time, atrophy develops with thinning of the deposited material and decreasing autofluorescence. The accumulated material is ultimately capable of inducing damage to the retinal pigment epithelium. Diseases causing accumulation of the material include central serous chorioretinopathy, vitelliform macular dystrophy, acute exudative polymorphous vitelliform maculopathy, choroidal tumors, and vitreomacular traction syndrome. The physical separation of the retinal outer segments from the retinal pigment epithelium hinders proper phagocytosis of the outer segments. Accumulation of the shed but not phagocytized outer segments plays a role in disease manifestations for a number of macular diseases.

  10. Potential applications of near infrared auto-fluorescence spectral polarized imaging for assessment of food quality

    Science.gov (United States)

    Zhou, Kenneth J.; Chen, Jun

    2016-03-01

    The current growing of food industry for low production costs and high efficiency needs for maintenance of high-quality standards and assurance of food safety while avoiding liability issues. Quality and safety of food depend on physical (texture, color, tenderness etc.), chemical (fat content, moisture, protein content, pH, etc.), and biological (total bacterial count etc.) features. There is a need for a rapid (less than a few minutes) and accurate detection system in order to optimize quality and assure safety of food. However, the fluorescence ranges for known fluorophores are limited to ultraviolet emission bands, which are not in the tissue near infrared (NIR) "optical window". Biological tissues excited by far-red or NIR light would exhibit strong emission in spectral range of 650-1,100 nm although no characteristic peaks show the emission from which known fluorophores. The characteristics of the auto-fluorescence emission of different types of tissues were found to be different between different tissue components such as fat, high quality muscle food. In this paper, NIR auto-fluorescence emission from different types of muscle food and fat was measured. The differences of fluorescence intensities of the different types of muscle food and fat emissions were observed. These can be explained by the change of the microscopic structure of physical, chemical, and biological features in meat. The difference of emission intensities of fat and lean meat tissues was applied to monitor food quality and safety using spectral polarized imaging, which can be detect deep depth fat under the muscle food up to several centimeter.

  11. Classification of endoscopic capsule images by using color wavelet features, higher order statistics and radial basis functions.

    Science.gov (United States)

    Lima, C S; Barbosa, D; Ramos, J; Tavares, A; Monteiro, L; Carvalho, L

    2008-01-01

    This paper presents a system to support medical diagnosis and detection of abnormal lesions by processing capsule endoscopic images. Endoscopic images possess rich information expressed by texture. Texture information can be efficiently extracted from medium scales of the wavelet transform. The set of features proposed in this paper to code textural information is named color wavelet covariance (CWC). CWC coefficients are based on the covariances of second order textural measures, an optimum subset of them is proposed. Third and forth order moments are added to cope with distributions that tend to become non-Gaussian, especially in some pathological cases. The proposed approach is supported by a classifier based on radial basis functions procedure for the characterization of the image regions along the video frames. The whole methodology has been applied on real data containing 6 full endoscopic exams and reached 95% specificity and 93% sensitivity.

  12. Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography

    Science.gov (United States)

    Herz, P. R.; Chen, Y.; Aguirre, A. D.; Schneider, K.; Hsiung, P.; Fujimoto, J. G.; Madden, K.; Schmitt, J.; Goodnow, J.; Petersen, C.

    2004-10-01

    A distally actuated, rotational-scanning micromotor endoscope catheter probe is demonstrated for ultrahigh-resolution in vivo endoscopic optical coherence tomography (OCT) imaging. The probe permits focus adjustment for visualization of tissue morphology at varying depths with improved transverse resolution compared with standard OCT imaging probes. The distal actuation avoids nonuniform scanning motion artifacts that are present with other probe designs and can permit a wider range of imaging speeds. Ultrahigh-resolution endoscopic imaging is demonstrated in a rabbit with micromotor endoscope catheter probe promises to improve OCT imaging performance in future endoscopic imaging applications.

  13. Segmentation of the geographic atrophy in spectral-domain optical coherence tomography and fundus autofluorescence images.

    Science.gov (United States)

    Hu, Zhihong; Medioni, Gerard G; Hernandez, Matthias; Hariri, Amirhossein; Wu, Xiaodong; Sadda, Srinivas R

    2013-12-30

    Geographic atrophy (GA) is the atrophic late-stage manifestation of age-related macular degeneration (AMD), which may result in severe vision loss and blindness. The purpose of this study was to develop a reliable, effective approach for GA segmentation in both spectral-domain optical coherence tomography (SD-OCT) and fundus autofluorescence (FAF) images using a level set-based approach and to compare the segmentation performance in the two modalities. To identify GA regions in SD-OCT images, three retinal surfaces were first segmented in volumetric SD-OCT images using a double-surface graph search scheme. A two-dimensional (2-D) partial OCT projection image was created from the segmented choroid layer. A level set approach was applied to segment the GA in the partial OCT projection image. In addition, the algorithm was applied to FAF images for the GA segmentation. Twenty randomly chosen macular SD-OCT (Zeiss Cirrus) volumes and 20 corresponding FAF (Heidelberg Spectralis) images were obtained from 20 subjects with GA. The algorithm-defined GA region was compared with consensus manual delineation performed by certified graders. The mean Dice similarity coefficients (DSC) between the algorithm- and manually defined GA regions were 0.87 ± 0.09 in partial OCT projection images and 0.89 ± 0.07 in registered FAF images. The area correlations between them were 0.93 (P segment GA regions in both SD-OCT and FAF images. This approach demonstrated good agreement between the algorithm- and manually defined GA regions within each single modality. The GA segmentation in FAF images performed better than in partial OCT projection images. Across the two modalities, the GA segmentation presented reasonable agreement.

  14. Endoscopic Tri-Modal Imaging (ETMI With Optical Magnification in the Detection of Barrett's Early Neoplasia

    Directory of Open Access Journals (Sweden)

    Sarmed S. Sami

    2014-01-01

    Full Text Available Early lesion detection and characterisation is vital to ensure accurate management in patients with gastrointestinal neoplasia. Endoscopic Tri-modal Imaging (ETMI technology has been shown to improve the targeted detection of early dysplastic lesions in Barrett's Oesophagus, but these results were not confirmed in non-expert hands [1]. This technology incorporates high resolution while light endoscopy (HRE, Auto Fluorescence Imaging (AFI and Narrow Band Imaging (NBI in one endoscope. The mucosa is first inspected with HRE, and then AFI is switched on to help in highlighting any suspicious areas in the mucosa [2]. These areas can be further examined by switching to NBI mode with magnification which helps to characterise mucosal patterns and identify early neoplasia [3].

  15. In vivo endoscopic OCT imaging of precancer and cancer states of human mucosa

    Science.gov (United States)

    Sergeev, Alexander M.; Gelikonov, V. M.; Gelikonov, G. V.; Feldchtein, Felix I.; Kuranov, R. V.; Gladkova, N. D.; Shakhova, N. M.; Snopova, L. B.; Shakhov, A. V.; Kuznetzova, I. A.; Denisenko, A. N.; Pochinko, V. V.; Chumakov, Yu P.; Streltzova, O. S.

    1997-12-01

    First results of endoscopic applications of optical coherence tomography for in vivo studies of human mucosa in respiratory, gastrointestinal, urinary and genital tracts are presented. A novel endoscopic OCT (EOCT) system has been created that is based on the integration of a sampling arm of an all-optical-fiber interferometer into standard endoscopic devices using their biopsy channel to transmit low-coherence radiation to investigated tissue. We have studied mucous membranes of esophagus, larynx, stomach, urinary bladder, uterine cervix and body as typical localization for carcinomatous processes. Images of tumor tissues versus healthy tissues have been recorded and analyzed. Violations of well-defined stratified healthy mucosa structure in cancered tissue are distinctly seen by EOCT, thus making this technique promising for early diagnosis of tumors and precise guiding of excisional biopsy.

  16. endoscope-i: an innovation in mobile endoscopic technology transforming the delivery of patient care in otolaryngology.

    Science.gov (United States)

    Mistry, N; Coulson, C; George, A

    2017-11-01

    Digital and mobile device technology in healthcare is a growing market. The introduction of the endoscope-i, the world's first endoscopic mobile imaging system, allows the acquisition of high definition images of the ear, nose and throat (ENT). The system combines the e-i Pro camera app with a bespoke engineered endoscope-i adaptor which fits securely onto the iPhone or iPod touch. Endoscopic examination forms a salient aspect of the ENT work-up. The endoscope-i therefore provides a mobile and compact alternative to the existing bulky endoscopic systems currently in use which often restrict the clinician to the clinic setting. Areas covered: This article gives a detailed overview of the endoscope-i system together with its applications. A review and comparison of alternative devices on the market offering smartphone adapted endoscopic viewing systems is also presented. Expert commentary: The endoscope-i fulfils unmet needs by providing a compact, highly portable, simple to use endoscopic viewing system which is cost-effective and which makes use of smartphone technology most clinicians have in their pocket. The system allows real-time feedback to the patient and has the potential to transform the way that healthcare is delivered in ENT as well as having applications further afield.

  17. Autofluorescence in eleocytes of some earthworm species.

    Directory of Open Access Journals (Sweden)

    Barbara Płytycz

    2006-04-01

    Full Text Available Immunocompetent cells of earthworms, coelomocytes, comprise adherent amoebocytes and granular eleocytes (chloragocytes. Both cell populations can be expelled via dorsal pores of adult earthworms by exposure to an electric current (4.5 V for 1 min. Analysis by phase contrast/fluorescence microscopy and flow cytometry demonstrated that eleocyte population of several species exhibits a strong autofluorescence. A high percentage (11-35% of autofluorescent eleocytes was recorded in Allolobophora chlorotica, Dendrodrilus rubidus, Eisenia fetida, and Octolasion sp. (O. cyaneum, O. tyrtaeum tyrtaeum and O. tyrtaeum lacteum. In contrast, autofluorescent coelomocytes were exceptionally scarce (less than 1% in representative Aporrectodea sp. (A. caliginosa and A. longa and Lumbricus sp. (L. castaneus, L. festivus, L. rubellus, L. terrestris. Thus, this paper for the first time describes profound intrinsic fluorescence of eleocytes in some--but not all--earthworm species. The function (if any and inter-species differences of the autofluorescent coelomocytes still remain elusive.

  18. Autofluorescence Imaging With Near-Infrared Excitation:Normalization by Reflectance to Reduce Signal From Choroidal Fluorophores

    Science.gov (United States)

    Cideciyan, Artur V.; Swider, Malgorzata; Jacobson, Samuel G.

    2015-01-01

    Purpose. We previously developed reduced-illuminance autofluorescence imaging (RAFI) methods involving near-infrared (NIR) excitation to image melanin-based fluorophores and short-wavelength (SW) excitation to image lipofuscin-based flurophores. Here, we propose to normalize NIR-RAFI in order to increase the relative contribution of retinal pigment epithelium (RPE) fluorophores. Methods. Retinal imaging was performed with a standard protocol holding system parameters invariant in healthy subjects and in patients. Normalized NIR-RAFI was derived by dividing NIR-RAFI signal by NIR reflectance point-by-point after image registration. Results. Regions of RPE atrophy in Stargardt disease, AMD, retinitis pigmentosa, choroideremia, and Leber congenital amaurosis as defined by low signal on SW-RAFI could correspond to a wide range of signal on NIR-RAFI depending on the contribution from the choroidal component. Retinal pigment epithelium atrophy tended to always correspond to high signal on NIR reflectance. Normalizing NIR-RAFI reduced the choroidal component of the signal in regions of atrophy. Quantitative evaluation of RPE atrophy area showed no significant differences between SW-RAFI and normalized NIR-RAFI. Conclusions. Imaging of RPE atrophy using lipofuscin-based AF imaging has become the gold standard. However, this technique involves bright SW lights that are uncomfortable and may accelerate the rate of disease progression in vulnerable retinas. The NIR-RAFI method developed here is a melanin-based alternative that is not absorbed by opsins and bisretinoid moieties, and is comfortable to view. Further development of this method may result in a nonmydriatic and comfortable imaging method to quantify RPE atrophy extent and its expansion rate. PMID:26024124

  19. Skin autofluorescence and all-cause mortality in stage 3 CKD.

    Science.gov (United States)

    Fraser, Simon D S; Roderick, Paul J; McIntyre, Natasha J; Harris, Scott; McIntyre, Christopher W; Fluck, Richard J; Taal, Maarten W

    2014-08-07

    Novel markers may help to improve risk prediction in CKD. One potential candidate is tissue advanced glycation end product accumulation, a marker of cumulative metabolic stress, which can be assessed by a simple noninvasive measurement of skin autofluorescence. Skin autofluorescence correlates with higher risk of cardiovascular events and mortality in people with diabetes or people requiring RRT, but its role in earlier CKD has not been studied. A prospective cohort of 1741 people with CKD stage 3 was recruited from primary care between August 2008 and March 2010. Participants underwent medical history, clinical assessment, blood and urine sampling for biochemistry, and measurement of skin autofluorescence. Kaplan-Meier plots and multivariate Cox proportional hazards models were used to investigate associations between skin autofluorescence (categorical in quartiles) and all-cause mortality. In total, 1707 participants had skin autofluorescence measured; 170 (10%) participants died after a median of 3.6 years of follow-up. The most common cause of death was cardiovascular disease (41%). Higher skin autofluorescence was associated significantly with poorer survival (all-cause mortality, Pskin autofluorescence was associated with all-cause mortality (hazard ratio, 2.64; 95% confidence interval, 1.71 to 4.08; PSkin autofluorescence was not independently associated with all-cause mortality in this study. Additional research is needed to clarify whether it has a role in risk prediction in CKD. Copyright © 2014 by the American Society of Nephrology.

  20. EVALUATION OF PATCHY ATROPHY SECONDARY TO HIGH MYOPIA BY SEMIAUTOMATED SOFTWARE FOR FUNDUS AUTOFLUORESCENCE ANALYSIS.

    Science.gov (United States)

    Miere, Alexandra; Capuano, Vittorio; Serra, Rita; Jung, Camille; Souied, Eric; Querques, Giuseppe

    2017-05-31

    To evaluate the progression of patchy atrophy in high myopia using semiautomated software for fundus autofluorescence (FAF) analysis. The medical records and multimodal imaging of 21 consecutive highly myopic patients with macular chorioretinal patchy atrophy (PA) were retrospectively analyzed. All patients underwent repeated fundus autofluorescence and spectral domain optical coherence tomography over at least 12 months. Color fundus photography was also performed in a subset of patients. Total atrophy area was measured on FAF images using Region Finder semiautomated software embedded in Spectralis (Heidelberg Engineering, Heidelberg, Germany) at baseline and during follow-up visits. Region Finder was compared with manually measured PA on FAF images. Twenty-two eyes of 21 patients (14 women, 7 men; mean age 62.8 + 13.0 years, range 32-84 years) were included. Mean PA area using Region Finder was 2.77 ± 2.91 SD mm at baseline, 3.12 ± 2.68 mm at Month 6, 3.43 ± 2.68 mm at Month 12, and 3.73 ± 2.74 mm at Month 18 (overall P autofluorescence analysis by Region Finder semiautomated software provides accurate measurements of lesion area and allows us to quantify the progression of PA in high myopia. In our series, PA enlarged significantly over at least 12 months, and its progression seemed to be related to the lesion size at baseline.

  1. Improved planning of endoscopic sinonasal surgery from 3-dimensional images with Osirix® and stereolithography.

    Science.gov (United States)

    Sánchez-Gómez, Serafín; Herrero-Salado, Tomás F; Maza-Solano, Juan M; Ropero-Romero, Francisco; González-García, Jaime; Ambrosiani-Fernández, Jesús

    2015-01-01

    The high variability of sinonasal anatomy requires the best knowledge of its three-dimensional (3D) conformation to perform surgery more safely and efficiently. The aim of the study was to validate the utility of Osirix® and stereolithography in improving endoscopic sinonasal surgery planning. Osirix® was used as a viewer and Digital Imaging and Communications in Medicine (DICOM) 3D imaging manager to improve planning for 114 sinonasal endoscopic operations with polyposis (86) and chronic rhinosinusitis (CRS) (28). Stereolithography rapid prototyping was used for 7 frontoethmoidal mucoceles. Using Osirix® and stereolithography, a greater number of anatomical structures were identified and this was done faster, with a statistically-significant clinical-radiological correlation (Pvirtual reality, allows surgeons to perform endoscopic sinonasal surgery with greater confidence and in less time than using 2D images. Residents also achieve surgical competence faster, more safely and with fewer complications. This beneficial impact is increased when the surgical team has stereolithography rapid prototyping in more complex cases. Copyright © 2014 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.

  2. Development of CMOS Imager Block for Capsule Endoscope

    International Nuclear Information System (INIS)

    Shafie, S; Fodzi, F A M; Tung, L Q; Lioe, D X; Halin, I A; Hasan, W Z W; Jaafar, H

    2014-01-01

    This paper presents the development of imager block to be associated in a capsule endoscopy system. Since the capsule endoscope is used to diagnose gastrointestinal diseases, the imager block must be in small size which is comfortable for the patients to swallow. In this project, a small size 1.5 V button battery is used as the power supply while the voltage supply requirements for other components such as microcontroller and CMOS image sensor are higher. Therefore, a voltage booster circuit is proposed to boost up the voltage supply from 1.5 V to 3.3 V. A low power microcontroller is used to generate control pulses for the CMOS image sensor and to convert the 8-bits parallel data output to serial data to be transmitted to the display panel. The results show that the voltage booster circuit was able to boost the voltage supply from 1.5 V to 3.3 V. The microcontroller precisely controls the CMOS image sensor to produce parallel data which is then serialized again by the microcontroller. The serial data is then successfully translated to 2fps image and displayed on computer.

  3. Endoscopic Cerenkov luminescence imaging: in vivo small animal tumor model validation

    Science.gov (United States)

    Song, Tianming; Bao, Chengpeng; Hu, Zhenhua; Wang, Kun; Liu, Xia; Tian, Jie

    2015-03-01

    Background: Cerenkov luminescence imaging (CLI) provides a great potential for clinical translation of optical molecular imaging techniques through using clinical approved radiotracers. However, it is difficult to obtain the Cerenkov luminescence signal of deeper biological tissues due to the small magnitude of the signal. To efficiently acquire the weak Cerenkov luminescence, we developed an endoscopic Cerenkov luminescence imaging (ECLI) system to reduce the in vivo imaging depth with minimum invasion, and validated the system on small animal tumor models. Methods: For the ECLI system, the laparoscope was connected to a high sensitive charge-couple device (CCD) camera (DU888+, Andor, UK) by a custom made adapter. We conducted a series of in vitro and in vivo experiments by use of the system. In the in vitro experiment, the endoscopic luminescence images of the 18F-FDG with various activities in EP tubes were acquired using ECLI system, and the sensitivity was compared with conventional CLI system. In the in vivo tumor experiment, 18F-FDG with the activity of 200μCi were intravenously injected into 3 tumor mice. Then the ECLI system was used to acquire the optical images for both non-invasive and invasive conditions. Conclusion: Experimental data showed the ECLI system could detect the 18F-FDG with the activity as low as 1μCi. Furthermore, our preliminary results indicated the possibility of ECLI technique for detecting Cerenkov signals inside the tumor tissue with deeper depth and guiding the surgical operation of tumor excision. We believe that this technique can help to accelerate the clinical translation of CLI.

  4. Fundus Autofluorescence and Photoreceptor Cell Rosettes in Mouse Models

    Science.gov (United States)

    Flynn, Erin; Ueda, Keiko; Auran, Emily; Sullivan, Jack M.; Sparrow, Janet R.

    2014-01-01

    Purpose. This study was conducted to study correlations among fundus autofluorescence (AF), RPE lipofuscin accumulation, and photoreceptor cell degeneration and to investigate the structural basis of fundus AF spots. Methods. Fundus AF images (55° lens; 488-nm excitation) and spectral-domain optical coherence tomography (SD-OCT) scans were acquired in pigmented Rdh8−/−/Abca4−/− mice (ages 1–9 months) with a confocal scanning laser ophthalmoscope (cSLO). For quantitative fundus AF (qAF), gray levels (GLs) were calibrated to an internal fluorescence reference. Retinal bisretinoids were measured by quantitative HPLC. Histometric analysis of outer nuclear layer (ONL) thicknesses was performed, and cryostat sections of retina were examined by fluorescence microscopy. Results. Quantified A2E and qAF intensities increased until age 4 months in the Rdh8−/−/Abca4−/− mice. The A2E levels declined after 4 months of age, but qAF intensity values continued to rise. The decline in A2E levels in the Rdh8−/−/Abca4−/− mice paralleled reduced photoreceptor cell viability as reflected in ONL thinning. Hyperautofluorescent puncta in fundus AF images corresponded to photoreceptor cell rosettes in SD-OCT images and histological sections stained with hematoxylin and eosin. The inner segment/outer segment–containing core of the rosette emitted an autofluorescence detected by fluorescence microscopy. Conclusions. When neural retina is disordered, AF from photoreceptor cells can contribute to noninvasive fundus AF images. Hyperautofluorescent puncta in fundus AF images are attributable, in at least some cases, to photoreceptor cell rosettes. PMID:25015357

  5. Endoscopic hyperspectral imaging: light guide optimization for spectral light source

    Science.gov (United States)

    Browning, Craig M.; Mayes, Samuel; Rich, Thomas C.; Leavesley, Silas J.

    2018-02-01

    Hyperspectral imaging (HSI) is a technology used in remote sensing, food processing and documentation recovery. Recently, this approach has been applied in the medical field to spectrally interrogate regions of interest within respective substrates. In spectral imaging, a two (spatial) dimensional image is collected, at many different (spectral) wavelengths, to sample spectral signatures from different regions and/or components within a sample. Here, we report on the use of hyperspectral imaging for endoscopic applications. Colorectal cancer is the 3rd leading cancer for incidences and deaths in the US. One factor of severity is the miss rate of precancerous/flat lesions ( 65% accuracy). Integrating HSI into colonoscopy procedures could minimize misdiagnosis and unnecessary resections. We have previously reported a working prototype light source with 16 high-powered light emitting diodes (LEDs) capable of high speed cycling and imaging. In recent testing, we have found our current prototype is limited by transmission loss ( 99%) through the multi-furcated solid light guide (lightpipe) and the desired framerate (20-30 fps) could not be achieved. Here, we report on a series of experimental and modeling studies to better optimize the lightpipe and the spectral endoscopy system as a whole. The lightpipe was experimentally evaluated using an integrating sphere and spectrometer (Ocean Optics). Modeling the lightpipe was performed using Monte Carlo optical ray tracing in TracePro (Lambda Research Corp.). Results of these optimization studies will aid in manufacturing a revised prototype with the newly designed light guide and increased sensitivity. Once the desired optical output (5-10 mW) is achieved then the HIS endoscope system will be able to be implemented without adding onto the procedure time.

  6. Application of artificial intelligence using a convolutional neural network for detecting gastric cancer in endoscopic images.

    Science.gov (United States)

    Hirasawa, Toshiaki; Aoyama, Kazuharu; Tanimoto, Tetsuya; Ishihara, Soichiro; Shichijo, Satoki; Ozawa, Tsuyoshi; Ohnishi, Tatsuya; Fujishiro, Mitsuhiro; Matsuo, Keigo; Fujisaki, Junko; Tada, Tomohiro

    2018-07-01

    Image recognition using artificial intelligence with deep learning through convolutional neural networks (CNNs) has dramatically improved and been increasingly applied to medical fields for diagnostic imaging. We developed a CNN that can automatically detect gastric cancer in endoscopic images. A CNN-based diagnostic system was constructed based on Single Shot MultiBox Detector architecture and trained using 13,584 endoscopic images of gastric cancer. To evaluate the diagnostic accuracy, an independent test set of 2296 stomach images collected from 69 consecutive patients with 77 gastric cancer lesions was applied to the constructed CNN. The CNN required 47 s to analyze 2296 test images. The CNN correctly diagnosed 71 of 77 gastric cancer lesions with an overall sensitivity of 92.2%, and 161 non-cancerous lesions were detected as gastric cancer, resulting in a positive predictive value of 30.6%. Seventy of the 71 lesions (98.6%) with a diameter of 6 mm or more as well as all invasive cancers were correctly detected. All missed lesions were superficially depressed and differentiated-type intramucosal cancers that were difficult to distinguish from gastritis even for experienced endoscopists. Nearly half of the false-positive lesions were gastritis with changes in color tone or an irregular mucosal surface. The constructed CNN system for detecting gastric cancer could process numerous stored endoscopic images in a very short time with a clinically relevant diagnostic ability. It may be well applicable to daily clinical practice to reduce the burden of endoscopists.

  7. Effect of pharmacologically induced retinal degeneration on retinal autofluorescence lifetimes in mice.

    Science.gov (United States)

    Dysli, Chantal; Dysli, Muriel; Zinkernagel, Martin S; Enzmann, Volker

    2016-12-01

    Fluorescence lifetime imaging ophthalmoscopy (FLIO) was used to investigate retinal autofluorescence lifetimes in mouse models of pharmacologically induced retinal degeneration over time. Sodium iodate (NaIO 3 , 35 mg/kg intravenously) was used to induce retinal pigment epithelium (RPE) degeneration with subsequent loss of photoreceptors (PR) whereas N-methyl-N-nitrosourea (MNU, 45 mg/kg intraperitoneally) was employed for degeneration of the photoreceptor cell layer alone. All mice were measured at day 3, 7, 14, and 28 after the respective injection of NaIO 3 , MNU or NaCl (control). Fluorescence lifetime imaging was performed using a fluorescence lifetime imaging ophthalmoscope (Heidelberg Engineering, Heidelberg, Germany). Fluorescence was excited at 473 nm and fluorescence lifetimes were measured in a short and a long spectral channel (498-560 nm and 560-720 nm). Corresponding optical coherence tomography (OCT) images were consecutively acquired and histology was performed at the end of the experiments. Segmentation of OCT images and histology verified the cell type-specific degeneration process over time. Retinal autofluorescence lifetimes increased from day 3 to day 28 in mice after NaIO 3 treatment. Finally, at day 28, fluorescence lifetimes were prolonged by 8% in the short and 61% in the long spectral channel compared to control animals (p = 0.21 and p = 0.004, respectively). In mice after MNU treatment, the mean retinal autofluorescence lifetimes were already decreased at day 3 and retinal lifetimes were finally shortened by 27% in the short and 51% in the long spectral channel at day 28 (p = 0.0028). In conclusion, degeneration of the RPE with subsequent photoreceptor degeneration by NaIO 3 lead to longer mean fluorescence lifetimes of the retina compared to control mice, whereas during specific degeneration of the photoreceptor layer induced by MNU shorter lifetimes were measured. Therefore, short retinal fluorescence lifetimes may originate

  8. Endoscopic OCT for in-vivo imaging of precancer and cancer states of human mucosa

    Science.gov (United States)

    Sergeev, Alexander M.; Gelikonov, Valentin M.; Gelikonov, Grigory V.; Feldchtein, Felix I.; Kuranov, Roman V.; Gladkova, Natalia D.; Shakhova, Natalia M.; Kuznetzova, Irina N.; Snopova, Ludmila; Denisenko, Arkady; Almasov, Valentin

    1998-01-01

    First results of endoscopic applications of optical coherence tomography for in vivo studies of human mucosa in gastrointestinal and genital tracts are presented. A novel endoscopic OCT system has ben created that is based on the integration of a sampling arm of an all-optical-fiber interferometer into standard endoscopic devices using their biopsy channel to transmit low-coherence radiation to investigated tissue. We have studied mucous membranes of esophagus, stomach and uterine cervix as typical localization for carcinomatous processes. Images of tumor tissues versus healthy tissues have been recorded and analyzed. Violations of well-defined stratified healthy mucosa structure in cancerous tissue is distinctly seen by EOCT, thus making this technique promising for early diagnosis of tumors and precise guiding of excisional biopsy.

  9. Trimodal endoscopic imaging for the detection and differentiation of colorectal adenomas: a prospective single-centre clinical evaluation.

    Science.gov (United States)

    Rotondano, Gianluca; Bianco, Maria Antonia; Sansone, Stefano; Prisco, Antonio; Meucci, Costantino; Garofano, Maria Lucia; Cipolletta, Livio

    2012-03-01

    The purpose of this study is to evaluate an endoscopic trimodal imaging (ETMI) system (high resolution, autofluorescence, and NBI) in the detection and differentiation of colorectal adenomas. A prospective randomised trial of tandem colonoscopies was carried out using the Olympus XCF-FH260AZI system. Each colonic segment was examined twice for lesions, once with HRE and once with AFI, in random order per patient. All detected lesions were assessed with NBI for pit pattern and with AFI for colour. All lesions were removed and sent for histology. Any lesion identified on the second examination was considered as missed by the first examination. Outcome measures are adenoma miss rates of AFI and HRE, and diagnostic accuracy of NBI and AFI for differentiating neoplastic from non-neoplastic lesions. Ninety-four patients underwent colonoscopy with ETMI (47 in each group). Among 47 patients examined with AFI first, 31 adenomas in 15 patients were detected initially [detection rate 0.66 (0.52-0.75)]. Subsequent HRE inspection identified six additional adenomas. Among 47 patients examined with HRE first, 29 adenomas in 14 patients were detected initially [detection rate 0.62 (0.53-0.79)]. Successive AFI yielded seven additional adenomas. Adenoma miss rates of AFI and HRE were 14% and 16.2%, respectively (p = 0.29). Accuracy of AFI alone for differentiation was lower than NBI (63% vs. 80%, p HRE. AFI alone had a disappointing accuracy for adenoma differentiation, which could be improved by combination of AFI and NBI.

  10. Molecular imaging for theranostics in gastroenterology: one stone to kill two birds.

    Science.gov (United States)

    Ko, Kwang Hyun; Kown, Chang-Il; Park, Jong Min; Lee, Hoo Geun; Han, Na Young; Hahm, Ki Baik

    2014-09-01

    Molecular imaging in gastroenterology has become more feasible with recent advances in imaging technology, molecular genetics, and next-generation biochemistry, in addition to advances in endoscopic imaging techniques including magnified high-resolution endoscopy, narrow band imaging or autofluorescence imaging, flexible spectral imaging color enhancement, and confocal laser endomicroscopy. These developments have the potential to serve as "red flag" techniques enabling the earlier and accurate detection of mucosal abnormalities (such as precancerous lesions) beyond biomarkers, virtual histology of detected lesions, and molecular targeted therapy-the strategy of "one stone to kill two or three birds"; however, more effort should be done to be "blue ocean" benefit. This review deals with the introduction of Raman spectroscopy endoscopy, imaging mass spectroscopy, and nanomolecule development for theranostics. Imaging of molecular pathological changes in cells/tissues/organs might open the "royal road" to either convincing diagnosis of diseases that otherwise would only be detected in the advanced stages or novel therapeutic methods targeted to personalized medicine.

  11. Riboflavin content in autofluorescent earthworm coelomocytes is species-specific.

    Directory of Open Access Journals (Sweden)

    Joanna Homa

    2007-01-01

    Full Text Available We have recently shown that a large proproportion of earthworm coelomocytes exhibit strong autofluorescence in some species (Dendrobaena veneta, Allolobophora chlorotica, Dendrodrilus rubidus, Eisenia fetida, and Octolasion spp., while autofluorescent coelomocytes are very scarce in representatives of Lumbricus spp. and Aporrectodea spp. Riboflavin (vitamin B2 was identified as a major fluorophore in Eisenia jetida coelomocytes. The main aim of the present experiments was to quantify riboflavin content in autofluorescent coelomocytes (eleocytes from several earthworm species through a combination of flow cytometric and spectrofluorometric measurements. Spectrofluorometry of coelomocyte lysates showed that riboflavin was non-detectable in the coelomocytes of Aporrectodea spp. and Lumbricus spp., but was a prominent constituent of lysates from species with autofluorescent eleocytes. In the latter case, riboflavin content was the highest in E. fetida, followed by Octolasion spp. > A. chlorotica > D. rubidus. The riboflavin content of coelomocytes correlates positively with eleocyte autofluorescence intensity measured by flow cytometry and visible with fluorescence microscopy.

  12. Method for radiometric calibration of an endoscope's camera and light source

    Science.gov (United States)

    Rai, Lav; Higgins, William E.

    2008-03-01

    An endoscope is a commonly used instrument for performing minimally invasive visual examination of the tissues inside the body. A physician uses the endoscopic video images to identify tissue abnormalities. The images, however, are highly dependent on the optical properties of the endoscope and its orientation and location with respect to the tissue structure. The analysis of endoscopic video images is, therefore, purely subjective. Studies suggest that the fusion of endoscopic video images (providing color and texture information) with virtual endoscopic views (providing structural information) can be useful for assessing various pathologies for several applications: (1) surgical simulation, training, and pedagogy; (2) the creation of a database for pathologies; and (3) the building of patient-specific models. Such fusion requires both geometric and radiometric alignment of endoscopic video images in the texture space. Inconsistent estimates of texture/color of the tissue surface result in seams when multiple endoscopic video images are combined together. This paper (1) identifies the endoscope-dependent variables to be calibrated for objective and consistent estimation of surface texture/color and (2) presents an integrated set of methods to measure them. Results show that the calibration method can be successfully used to estimate objective color/texture values for simple planar scenes, whereas uncalibrated endoscopes performed very poorly for the same tests.

  13. Optical design of an optical coherence tomography and multispectral fluorescence imaging endoscope to detect early stage ovarian cancer

    Science.gov (United States)

    Tate, Tyler; Keenan, Molly; Swan, Elizabeth; Black, John; Utzinger, Urs; Barton, Jennifer

    2014-12-01

    The five year survival rate for ovarian cancer is over 90% if early detection occurs, yet no effective early screening method exists. We have designed and are constructing a dual modality Optical Coherence Tomography (OCT) and Multispectral Fluorescence Imaging (MFI) endoscope to optically screen the Fallopian tube and ovary for early stage cancer. The endoscope reaches the ovary via the natural pathway of the vagina, cervix, uterus and Fallopian tube. In order to navigate the Fallopian tube the endoscope must have an outer diameter of 600 μm, be highly flexible, steerable, tracking and nonperforating. The imaging systems consists of six optical subsystems, two from OCT and four from MFI. The optical subsystems have independent and interrelated design criteria. The endoscope will be tested on realistic tissue models and ex vivo tissue to prove feasibility of future human trials. Ultimately the project aims to provide women the first effective ovarian cancer screening technique.

  14. Autofluorescence: A screening test for mycotic infection in tissues

    Directory of Open Access Journals (Sweden)

    Rao Shalinee

    2008-04-01

    Full Text Available Fungal infection is a major health concern as the clinical features are not very distinctive. Lack of rapid diagnostic techniques results in delay in diagnosis, which may even culminate in a fatal outcome. The fact that many pathogenic fungal organisms autofluoresce in hematoxylin and eosin (H and E-stained sections under ultraviolet illumination led us to evaluate the role of autofluorescence as a rapid screening technique for fungal infections. The aim of the present study was to assess the value of autofluorescence as a screening method for detecting fungi on tissue sections and to compare the results of autofluorescence with conventional histochemical stains for fungi. Hematoxylin and eosin-stained slides of mycotic lesions were examined under fluorescent microscope and the findings were compared with results of Gomori′s methenamine silver and periodic acid-Schiff stains. We found fungal autofluorescence in 63 out of 64 cases studied, with a sensitivity of 97.8% and specificity of 100% in comparison with fungal stains. This was statistically significant (P < 0.05. We conclude that autofluorescence can be used as a rapid screening method for identification of fungi in tissue sections as it does not require any other specialized staining procedure

  15. Emphysema. Imaging for endoscopic lung volume reduction; Lungenemphysem. Bildgebung bei endoskopischer Lungenvolumenreduktion

    Energy Technology Data Exchange (ETDEWEB)

    Storbeck, B. [LungenClinic Grosshansdorf (Germany). Dept. of Radiology; Schroeder, T.H. [Amalie Sieveking-Hospital, Diagnostic and Interventional Radiology, Hamburg (Germany); Oldigs, M.; Rabe, K.F. [LungenClinic Grosshansdorf (Germany). Dept. of Pulmonology; Weber, C. [Amalie Sieveking-Hospital, Diagnostic and Interventional Radiology, Hamburg (Germany); University Medical Center Hamburg-Eppendorf (Germany). Diagnostic and Interventional Radiology

    2015-07-15

    Chronic obstructive pulmonary disease (COPD) is characterized by two entities, the more airway-predominant type (''bronchitis'') on the one hand, and emphysema-predominant type on the other. Imaging via high-resolution computed tomography plays an important role in phenotyping COPD. For patients with advanced lung emphysema, new endoscopic lung volume reduction therapies (ELVR) have been developed. Proper selection of suitable patients requires thin-section reconstruction of volumetric CT image data sets also in coronal and sagittal orientation are required. In the current manuscript we will describe emphysema subtypes (centrilobular, paraseptal, panlobular), options for quantifying emphysema and this importance of regional distribution (homogeneous or heterogeneous, target area) as this is crucial for patient selection. Analysis of the interlobular fissures is obligatory despite the lack of standardization, as incomplete fissures indicate collateral ventilation (CV) via parenchymal bridges, which is an important criterion in choosing endoscopic methods of LVR. Every radiologist should be familiar with modern LVR therapies such as valves and coils, and furthermore should know what a lung doctor expects from radiologic evaluation (before and after ELVR). Finally we present a checklist as a quick reference for all steps concerning imaging for ELVR.

  16. The combination design for open and endoscopic surgery using fluorescence molecular imaging technology

    Science.gov (United States)

    Mao, Yamin; Jiang, Shixin; Ye, Jinzuo; An, Yu; Yang, Xin; Chi, Chongwei; Tian, Jie

    2015-03-01

    For clinical surgery, it is still a challenge to objectively determine tumor margins during surgery. With the development of medical imaging technology, fluorescence molecular imaging (FMI) method can provide real-time intraoperative tumor margin information. Furthermore, surgical navigation system based on FMI technology plays an important role for the aid of surgeons' precise tumor margin decision. However, detection depth is the most limitation exists in the FMI technique and the method convenient for either macro superficial detection or micro deep tissue detection is needed. In this study, we combined advantages of both open surgery and endoscopic imaging systems with FMI technology. Indocyanine green (ICG) experiments were performed to confirm the feasibility of fluorescence detection in our system. Then, the ICG signal was photographed in the detection area with our system. When the system connected with endoscope lens, the minimum quantity of ICG detected by our system was 0.195 ug. For aspect of C mount lens, the sensitivity of ICG detection with our system was 0.195ug. Our experiments results proved that it was feasible to detect fluorescence images with this combination method. Our system shows great potential in the clinical applications of precise dissection of various tumors

  17. A novel fusion imaging system for endoscopic ultrasound

    DEFF Research Database (Denmark)

    Gruionu, Lucian Gheorghe; Saftoiu, Adrian; Gruionu, Gabriel

    2016-01-01

    BACKGROUND AND OBJECTIVE: Navigation of a flexible endoscopic ultrasound (EUS) probe inside the gastrointestinal (GI) tract is problematic due to the small window size and complex anatomy. The goal of the present study was to test the feasibility of a novel fusion imaging (FI) system which uses...... time was 24.6 ± 6.6 min, while the time to reach the clinical target was 8.7 ± 4.2 min. CONCLUSIONS: The FI system is feasible for clinical use, and can reduce the learning curve for EUS procedures and improve navigation and targeting in difficult anatomic locations....

  18. An evaluation of fundus photography and fundus autofluorescence in the diagnosis of cuticular drusen

    DEFF Research Database (Denmark)

    Høeg, Tracy B; Moldow, Birgitte; Klein, Ronald

    2016-01-01

    PURPOSE: To examine non-mydriatic fundus photography (FP) and fundus autofluorescence (FAF) as alternative non-invasive imaging modalities to fluorescein angiography (FA) in the detection of cuticular drusen (CD). METHODS: Among 2953 adults from the Danish Rural Eye Study (DRES) with gradable FP...

  19. Multi-color autofluorescence and scattering spectroscopy provides rapid assessment of kidney function following ischemic injury

    Science.gov (United States)

    Raman, Rajesh N.; Pivetti, Chris D.; Ramsamooj, Rajendra; Troppmann, Christoph; Demos, Stavros G.

    2018-02-01

    A major source of kidneys for transplant comes from deceased donors whose tissues have suffered an unknown amount of warm ischemia prior to retrieval, with no quantitative means to assess function before transplant. Toward addressing this need, non-contact monitoring of optical signatures in rat kidneys was performed in vivo during ischemia and reperfusion. Kidney autofluorescence images were captured under ultraviolet illumination (355 nm, 325 nm, and 266 nm) in order to provide information on related metabolic and non-metabolic response. In addition, light scattering images under 355 nm, 325 nm, and 266 nm, 500 nm illumination were monitored to report on changes in kidney optical properties giving rise to the observed autofluorescence signals during these processes. During reperfusion, various signal ratios were generated from the recorded signals and then parametrized. Time-dependent parameters derived from the ratio of autofluorescence under 355 nm excitation to that under 266 nm excitation, as well as from 500 nm scattered signal, were found capable of discriminating dysfunctional kidneys from those that were functional (p Kidney dysfunction was confirmed by subsequent survival study and histology following autopsy up to a week later. Physiologic changes potentially giving rise to the observed signals, including those in cellular metabolism, vascular response, tissue microstructure, and microenvironment chemistry, are discussed.

  20. High resolution axicon-based endoscopic FD OCT imaging with a large depth range

    Science.gov (United States)

    Lee, Kye-Sung; Hurley, William; Deegan, John; Dean, Scott; Rolland, Jannick P.

    2010-02-01

    Endoscopic imaging in tubular structures, such as the tracheobronchial tree, could benefit from imaging optics with an extended depth of focus (DOF). This optics could accommodate for varying sizes of tubular structures across patients and along the tree within a single patient. In the paper, we demonstrate an extended DOF without sacrificing resolution showing rotational images in biological tubular samples with 2.5 μm axial resolution, 10 ìm lateral resolution, and > 4 mm depth range using a custom designed probe.

  1. Early Use of Magnetic Endoscopic Imaging by Novice Colonoscopists: Improved Performance without Increase in Workload

    Directory of Open Access Journals (Sweden)

    Sylvain Coderre

    2010-01-01

    Full Text Available BACKGROUND: Magnetic endoscopic imaging represents a recent advance in colonoscopy training. This technique provides adjunct information to the endoscopist, specifically with regard to colonoscope loop formation.

  2. First Application of 7T Magnetic Resonance Imaging in Endoscopic Endonasal Surgery of Skull Base Tumors

    Science.gov (United States)

    Barrett, Thomas F; Dyvorne, Hadrien A; Padormo, Francesco; Pawha, Puneet S; Delman, Bradley N; Shrivastava, Raj K; Balchandani, Priti

    2018-01-01

    Background Successful endoscopic endonasal surgery for the resection of skull base tumors is reliant on preoperative imaging to delineate pathology from the surrounding anatomy. The increased signal-to-noise ratio afforded by 7T MRI can be used to increase spatial and contrast resolution, which may lend itself to improved imaging of skull base. In this study, we apply a 7T imaging protocol to patients with skull base tumors and compare the images to clinical standard of care. Methods Images were acquired at 7T on 11 patients with skull base lesions. Two neuroradiologists evaluated clinical 1.5T, 3T, and 7T scans for detection of intracavernous cranial nerves and ICA branches. Detection rates were compared. Images were utilized for surgical planning and uploaded to a neuronavigation platform and used to guide surgery. Results Image analysis yielded improved detection rates of cranial nerves and ICA branches at 7T. 7T images were successfully incorporated into preoperative planning and intraoperative neuronavigation. Conclusion Our study represents the first application of 7T MRI to the full neurosurgical workflow for endoscopic endonasal surgery. We detected higher rates of cranial nerves and ICA branches at 7T MRI compared to 3T and 1.5 T, and found that integration of 7T into surgical planning and guidance was feasible. These results suggest a potential for 7T MRI to reduce surgical complications. Future studies comparing standardized 7T, 3T, and 1.5 T MRI protocols in a larger number of patients are warranted to determine the relative benefit of 7T MRI for endonasal endoscopic surgical efficacy. PMID:28359922

  3. First Application of 7-T Magnetic Resonance Imaging in Endoscopic Endonasal Surgery of Skull Base Tumors.

    Science.gov (United States)

    Barrett, Thomas F; Dyvorne, Hadrien A; Padormo, Francesco; Pawha, Puneet S; Delman, Bradley N; Shrivastava, Raj K; Balchandani, Priti

    2017-07-01

    Successful endoscopic endonasal surgery for the resection of skull base tumors is reliant on preoperative imaging to delineate pathology from the surrounding anatomy. The increased signal-to-noise ratio afforded by 7-T MRI can be used to increase spatial and contrast resolution, which may lend itself to improved imaging of the skull base. In this study, we apply a 7-T imaging protocol to patients with skull base tumors and compare the images with clinical standard of care. Images were acquired at 7 T on 11 patients with skull base lesions. Two neuroradiologists evaluated clinical 1.5-, 3-, and 7-T scans for detection of intracavernous cranial nerves and internal carotid artery (ICA) branches. Detection rates were compared. Images were used for surgical planning and uploaded to a neuronavigation platform and used to guide surgery. Image analysis yielded improved detection rates of cranial nerves and ICA branches at 7 T. The 7-T images were successfully incorporated into preoperative planning and intraoperative neuronavigation. Our study represents the first application of 7-T MRI to the full neurosurgical workflow for endoscopic endonasal surgery. We detected higher rates of cranial nerves and ICA branches at 7-T MRI compared with 3- and 1.5-T MRI, and found that integration of 7 T into surgical planning and guidance was feasible. These results suggest a potential for 7-T MRI to reduce surgical complications. Future studies comparing standardized 7-, 3-, and 1.5-T MRI protocols in a larger number of patients are warranted to determine the relative benefit of 7-T MRI for endonasal endoscopic surgical efficacy. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Efficient simulation of autofluorescence effects in microscopic lenses

    DEFF Research Database (Denmark)

    Gross, Herbert; Rodenko, Olga; Esslinger, Moritz

    2015-01-01

    The use of fluorescence in microscopy is a well known technology today. Due to the autofluorescence of the materials of the optical system components, the contrast of the images is degraded. The calculation of autofluorescense usually is performed by brute force methods as volume scattering...... of the domains are determined by simple tracing of the limiting rays of the light cone of the source as well as the pixel area under consideration. The small overlap of both domains can be estimated by geometrical considerations. The correct photometric scaling and the discretization of the volumes must...

  5. Skin autofluorescence associates with vascular calcification in chronic kidney disease.

    Science.gov (United States)

    Wang, Angela Yee-Moon; Wong, Chun-Kwok; Yau, Yat-Yin; Wong, Sharon; Chan, Iris Hiu-Shuen; Lam, Christopher Wai-Kei

    2014-08-01

    This study aims to evaluate the relationship between tissue advanced glycation end products, as reflected by skin autofluorescence, and vascular calcification in chronic kidney disease. Three hundred patients with stage 3 to 5 chronic kidney disease underwent multislice computed tomography to estimate total coronary artery calcium score (CACS) and had tissue advanced glycation end product assessed using a skin autofluorescence reader. Intact parathyroid hormone (Pskin autofluorescence after age (Pskin autofluorescence was associated with a 7.43-fold (95% confidence intervals, 3.59-15.37; PSkin autofluorescence retained significance in predicting CACS ≥400 (odds ratio, 3.63; 95% confidence intervals, 1.44-9.18; P=0.006) when adjusting for age, sex, serum calcium, phosphate, albumin, C-reactive protein, lipids, blood pressure, estimated glomerular filtration rate, and intact parathyroid hormone but marginally lost significance when additionally adjusting for diabetes mellitus (odds ratio, 2.23; 95% confidence intervals, 0.81-6.14; P=0.1). Combination of diabetes mellitus and higher intact parathyroid hormone was associated with greater skin autofluorescence and CACS versus those without diabetes mellitus and having lower intact parathyroid hormone. Tissue advanced glycation end product, as reflected by skin autofluorescence, showed a significant novel association with vascular calcification in chronic kidney disease. These data suggest that increased tissue advanced glycation end product may contribute to vascular calcification in chronic kidney disease and diabetes mellitus and warrant further experimental investigation. © 2014 American Heart Association, Inc.

  6. Scoping the scope: endoscopic evaluation of endoscope working channels with a new high-resolution inspection endoscope (with video).

    Science.gov (United States)

    Barakat, Monique T; Girotra, Mohit; Huang, Robert J; Banerjee, Subhas

    2018-02-06

    Outbreaks of transmission of infection related to endoscopy despite reported adherence to reprocessing guidelines warrant scrutiny of all potential contributing factors. Recent reports from ambulatory surgery centers indicated widespread significant occult damage within endoscope working channels, raising concerns regarding the potential detrimental impact of this damage on the adequacy of endoscope reprocessing. We inspected working channels of all 68 endoscopes at our academic institution using a novel flexible inspection endoscope. Inspections were recorded and videos reviewed by 3 investigators to evaluate and rate channel damage and/or debris. Working channel rinsates were obtained from all endoscopes, and adenosine triphosphate (ATP) bioluminescence was measured. Overall endoscope working channel damage was rated as minimal and/or mild and was consistent with expected wear and tear (median 1.59 on our 5-point scale). Our predominant findings included superficial scratches (98.5%) and scratches with adherent peel (76.5%). No channel perforations, stains, or burns were detected. The extent of damage was not predicted by endoscope age. Minor punctate debris was common, and a few small drops of fluid were noted in 42.6% of endoscopes after reprocessing and drying. The presence of residual fluid predicted higher ATP bioluminescence values. The presence of visualized working channel damage or debris was not associated with elevated ATP bioluminescence values. The flexible inspection endoscope enables high-resolution imaging of endoscope working channels and offers endoscopy units an additional modality for endoscope surveillance, potentially complementing bacterial cultures and ATP values. Our study, conducted in a busy academic endoscopy unit, indicated predominately mild damage to endoscope working channels, which did not correlate with elevated ATP values. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights

  7. Noninvasive near infrared autofluorescence imaging of retinal pigment epithelial cells in the human retina using adaptive optics.

    Science.gov (United States)

    Liu, Tao; Jung, HaeWon; Liu, Jianfei; Droettboom, Michael; Tam, Johnny

    2017-10-01

    The retinal pigment epithelial (RPE) cells contain intrinsic fluorophores that can be visualized using infrared autofluorescence (IRAF). Although IRAF is routinely utilized in the clinic for visualizing retinal health and disease, currently, it is not possible to discern cellular details using IRAF due to limits in resolution. We demonstrate that the combination of adaptive optics (AO) with IRAF (AO-IRAF) enables higher-resolution imaging of the IRAF signal, revealing the RPE mosaic in the living human eye. Quantitative analysis of visualized RPE cells in 10 healthy subjects across various eccentricities demonstrates the possibility for in vivo density measurements of RPE cells, which range from 6505 to 5388 cells/mm 2 for the areas measured (peaking at the fovea). We also identified cone photoreceptors in relation to underlying RPE cells, and found that RPE cells support on average up to 18.74 cone photoreceptors in the fovea down to an average of 1.03 cone photoreceptors per RPE cell at an eccentricity of 6 mm. Clinical application of AO-IRAF to a patient with retinitis pigmentosa illustrates the potential for AO-IRAF imaging to become a valuable complementary approach to the current landscape of high resolution imaging modalities.

  8. Retinal pigment epithelial changes in chronic Vogt-Koyanagi-Harada disease: fundus autofluorescence and spectral domain optical coherence tomography findings

    Science.gov (United States)

    Vasconcelos-Santos, Daniel V.; Sohn, Elliott H.; Sadda, Srinivas; Rao, Narsing A.

    2009-01-01

    Purpose To determine whether fundus autofluorescence (FAF) and spectral-domain optical coherence tomography (SD-OCT) imaging allows better assessment of RPE and outer retina (OR) in subjects with chronic VKH compared to examination and angiography alone. Methods Cross-sectional analysis of a series of seven consecutive patients with chronic VKH undergoing FAF and SD-OCT. Chronic VKH was defined as during >3 months. Color fundus photographs were correlated to FAF and SD-OCT images. The images were later correlated to fluorescein angiography (FA) and indocyanine green angiography (ICG-A). Results All patients had sunset glow fundus, which resulted in no apparent corresponding abnormality on FAF or SD-OCT. Lesions with decreased autofluorescence signal were observed in 11 eyes (85%), being associated with loss of the RPE and involvement of OR on SD-OCT. In 5 eyes (38%) some of these lesions were very subtle on clinical examination but easily detected by FAF. Lesions with increased autofluorescence signal were seen in 8 eyes (61.5%), showing variable involvement of the OR on SD-OCT and corresponding clinically to areas of RPE proliferation and cystoid macular edema. Conclusion Combined use of FAF and SD-OCT imaging allowed noninvasive delineation of RPE/OR changes in patients with chronic VKH, which were consistent with previous histopathological reports. Some of these changes were not apparent on clinical examination. PMID:20010321

  9. Autofluorescence and high-definition optical coherence tomography of retinal artery occlusions

    Directory of Open Access Journals (Sweden)

    Raeba Mathew

    2010-10-01

    Full Text Available Raeba Mathew, Evangelia Papavasileiou, Sobha SivaprasadLaser and Retinal Research Unit, Department of Ophthalmology, King’s College Hospital, Denmark Hill, London, UKBackground: The purpose of this study is to illustrate the fundus autofluorescence and high-definition optical coherence tomography (HD-OCT features of acute and long-standing retinal artery occlusions.Design: Retrospective case series.Participants: Patients with acute and chronic retinal and cilioretinal artery occlusions are included in this series.Methods: A detailed clinical examination, color fundus photographs, autofluorescence, and HD-OCT of the subjects were performed.Results: HD-OCT demonstrates the localized and well-demarcated thickening of the inner retina in the acute phase of arterial occlusions that correlates with the areas of blocked autofluorescence caused by the cloudy swelling of the retina. The areas of blocked autofluorescence disappear with chronicity of the disease and this corresponds to the thinning of the inner retinal layers on HD-OCT.Conclusion: Heidelberg OCT and autofluorescence are useful tools to assess retinal arterial occlusions especially in subjects with unexplained visual field loss.Keywords: autofluorescence, high definition OCT, retinal artery occlusion

  10. Characteristics of Fundus Autofluorescence in Active Polypoidal Choroidal Vasculopathy

    Directory of Open Access Journals (Sweden)

    Zafer Öztaş

    2016-08-01

    Full Text Available Objectives: To define characteristic fundus autofluorescence (FAF findings in eyes with active polypoidal choroidal vasculopathy (PCV. Materials and Methods: Thirty-five eyes of 29 patients with active PCV who were diagnosed at Ege University Faculty of Medicine, Department of Ophthalmology, Retina Division between January 2012 and November 2014 were included in the study. All the patients underwent a complete ophthalmological examination including fundus photography, spectral-domain optical coherence tomography, fluorescein angiography, FAF photography, and indocyanine green angiography (ICGA. ICGA was used to diagnose active PCV and identify lesion components. FAF findings were described at the retinal site of the corresponding lesions identified and diagnosed using ICGA. Results: The mean age of the 29 study patients (15 men, 14 women was 64.6±7.5 years (range, 54-82 years. ICGA revealed active PCV in 35 eyes, consisting of polypoid lesions in 11 eyes (31.4%, branching vascular networks (BVN in 10 eyes (28.6%, and a combination of polypoid lesions and BVNs in 14 eyes (40%. On FAF images, 4 different patterns were detected at the corresponding retinal sites of 25 polypoid lesions detected by ICGA: confluent hypoautofluorescence with a hyperautofluorescent ring in 18 eyes (72%, hyperautofluorescence with hypoautofluorescent ring in 2 eyes (8%, confluent hypoautofluorescence in 1 eye (4%, and granular hypoautofluorescence in 1 eye (4%. The remaining 3 eyes (12% demonstrated blocked hypoautofluorescence because of the excessive hemorrhaging in the macula. The FAF images showed the granular hypoautofluorescent FAF pattern in all 24 BVNs (100% consistent with the location of the lesions on ICGA. Conclusion: The typical PCV lesions, polypoid lesions and BVNs had characteristic autofluorescent findings on FAF imaging. Non-invasive, quick, and repeatable FAF imaging can be considered a reliable and helpful diagnostic technique for the diagnosis of

  11. Towards automated visual flexible endoscope navigation.

    Science.gov (United States)

    van der Stap, Nanda; van der Heijden, Ferdinand; Broeders, Ivo A M J

    2013-10-01

    The design of flexible endoscopes has not changed significantly in the past 50 years. A trend is observed towards a wider application of flexible endoscopes with an increasing role in complex intraluminal therapeutic procedures. The nonintuitive and nonergonomical steering mechanism now forms a barrier in the extension of flexible endoscope applications. Automating the navigation of endoscopes could be a solution for this problem. This paper summarizes the current state of the art in image-based navigation algorithms. The objectives are to find the most promising navigation system(s) to date and to indicate fields for further research. A systematic literature search was performed using three general search terms in two medical-technological literature databases. Papers were included according to the inclusion criteria. A total of 135 papers were analyzed. Ultimately, 26 were included. Navigation often is based on visual information, which means steering the endoscope using the images that the endoscope produces. Two main techniques are described: lumen centralization and visual odometry. Although the research results are promising, no successful, commercially available automated flexible endoscopy system exists to date. Automated systems that employ conventional flexible endoscopes show the most promising prospects in terms of cost and applicability. To produce such a system, the research focus should lie on finding low-cost mechatronics and technologically robust steering algorithms. Additional functionality and increased efficiency can be obtained through software development. The first priority is to find real-time, robust steering algorithms. These algorithms need to handle bubbles, motion blur, and other image artifacts without disrupting the steering process.

  12. Possible role for fundus autofluorescence as a predictive factor for visual acuity recovery after epiretinal membrane surgery.

    Science.gov (United States)

    Brito, Pedro N; Gomes, Nuno L; Vieira, Marco P; Faria, Pedro A; Fernandes, Augusto V; Rocha-Sousa, Amândio; Falcão-Reis, Fernando

    2014-02-01

    To study the potential association between fundus autofluorescence, spectral-domain optical coherence tomography, and visual acuity in patients undergoing surgery because of epiretinal membranes. Prospective, interventional case series including 26 patients submitted to vitrectomy because of symptomatic epiretinal membranes. Preoperative evaluation consisted of a complete ophthalmologic examination, autofluorescence, and spectral-domain optical coherence tomography. Studied variables included foveal autofluorescence (fov.AF), photoreceptor inner segment/outer segment (IS/OS) junction line integrity, external limiting membrane integrity, central foveal thickness, and foveal morphology. All examinations were repeated at the first, third, and sixth postoperative months. The main outcome measures were logarithm of minimal angle resolution visual acuity, fov.AF integrity, and IS/OS integrity. All cases showing a continuous IS/OS line had an intact fov.AF, whereas patients with IS/OS disruption could have either an increased area of foveal hypoautofluorescence or an intact fov.AF, with the latter being associated with IS/OS integrity recovery in follow-up spectral-domain optical coherence tomography imaging. The only preoperative variables presenting a significant correlation with final visual acuity were baseline visual acuity (P = 0.047) and fov.AF grade (P = 0.023). Recovery of IS/OS line integrity after surgery, in patients with preoperative IS/OS disruption and normal fov.AF, can be explained by the presence of a functional retinal pigment epithelium-photoreceptor complex, supporting normal photoreceptor activity. Autofluorescence imaging provides a functional component to the study of epiretinal membranes, complementing the structural information obtained with optical coherence tomography.

  13. Segmentation of Clinical Endoscopic Images Based on the Classification of Topological Vector Features

    Directory of Open Access Journals (Sweden)

    O. A. Dunaeva

    2013-01-01

    Full Text Available In this work, we describe a prototype of an automatic segmentation system and annotation of endoscopy images. The used algorithm is based on the classification of vectors of the topological features of the original image. We use the image processing scheme which includes image preprocessing, calculation of vector descriptors defined for every point of the source image and the subsequent classification of descriptors. Image preprocessing includes finding and selecting artifacts and equalizating the image brightness. In this work, we give the detailed algorithm of the construction of topological descriptors and the classifier creating procedure based on mutual sharing the AdaBoost scheme and a naive Bayes classifier. In the final section, we show the results of the classification of real endoscopic images.

  14. Fundus autofluorescence in the diagnosis and monitoring of acute retinal necrosis

    OpenAIRE

    Ward, Tyson SJ; Reddy, Ashvini K

    2015-01-01

    Background Acute retinal necrosis (ARN), a vision threatening viral retinitis, is often diagnosed and treated based on clinical findings. These clinical features have been well characterized by various imaging modalities, but not using fundus autofluorescence (FAF), a noninvasive method of evaluating the neurosensory retina and retinal pigment epithelium (RPE) based on the detection of endogenous fluorophores. Findings A patient diagnosed with ARN was followed over a 10-month period to identi...

  15. Automated endoscopic navigation and advisory system from medical image

    Science.gov (United States)

    Kwoh, Chee K.; Khan, Gul N.; Gillies, Duncan F.

    1999-05-01

    In this paper, we present a review of the research conducted by our group to design an automatic endoscope navigation and advisory system. The whole system can be viewed as a two-layer system. The first layer is at the signal level, which consists of the processing that will be performed on a series of images to extract all the identifiable features. The information is purely dependent on what can be extracted from the 'raw' images. At the signal level, the first task is performed by detecting a single dominant feature, lumen. Few methods of identifying the lumen are proposed. The first method used contour extraction. Contours are extracted by edge detection, thresholding and linking. This method required images to be divided into overlapping squares (8 by 8 or 4 by 4) where line segments are extracted by using a Hough transform. Perceptual criteria such as proximity, connectivity, similarity in orientation, contrast and edge pixel intensity, are used to group edges both strong and weak. This approach is called perceptual grouping. The second method is based on a region extraction using split and merge approach using spatial domain data. An n-level (for a 2' by 2' image) quadtree based pyramid structure is constructed to find the most homogenous large dark region, which in most cases corresponds to the lumen. The algorithm constructs the quadtree from the bottom (pixel) level upward, recursively and computes the mean and variance of image regions corresponding to quadtree nodes. On reaching the root, the largest uniform seed region, whose mean corresponds to a lumen is selected that is grown by merging with its neighboring regions. In addition to the use of two- dimensional information in the form of regions and contours, three-dimensional shape can provide additional information that will enhance the system capabilities. Shape or depth information from an image is estimated by various methods. A particular technique suitable for endoscopy is the shape from shading

  16. Association of age and macular pigment optical density using dual-wavelength autofluorescence imaging

    Directory of Open Access Journals (Sweden)

    Lima VC

    2013-04-01

    after 60 years of age.Keywords: age, macular pigment optical density, dual-wavelength autofluorescence imaging, association

  17. Near-infrared spectroscopic tissue imaging for medical applications

    Science.gov (United States)

    Demos, Stavros [Livermore, CA; Staggs, Michael C [Tracy, CA

    2006-12-12

    Near infrared imaging using elastic light scattering and tissue autofluorescence are explored for medical applications. The approach involves imaging using cross-polarized elastic light scattering and tissue autofluorescence in the Near Infra-Red (NIR) coupled with image processing and inter-image operations to differentiate human tissue components.

  18. Principle component analysis and linear discriminant analysis of multi-spectral autofluorescence imaging data for differentiating basal cell carcinoma and healthy skin

    Science.gov (United States)

    Chernomyrdin, Nikita V.; Zaytsev, Kirill I.; Lesnichaya, Anastasiya D.; Kudrin, Konstantin G.; Cherkasova, Olga P.; Kurlov, Vladimir N.; Shikunova, Irina A.; Perchik, Alexei V.; Yurchenko, Stanislav O.; Reshetov, Igor V.

    2016-09-01

    In present paper, an ability to differentiate basal cell carcinoma (BCC) and healthy skin by combining multi-spectral autofluorescence imaging, principle component analysis (PCA), and linear discriminant analysis (LDA) has been demonstrated. For this purpose, the experimental setup, which includes excitation and detection branches, has been assembled. The excitation branch utilizes a mercury arc lamp equipped with a 365-nm narrow-linewidth excitation filter, a beam homogenizer, and a mechanical chopper. The detection branch employs a set of bandpass filters with the central wavelength of spectral transparency of λ = 400, 450, 500, and 550 nm, and a digital camera. The setup has been used to study three samples of freshly excised BCC. PCA and LDA have been implemented to analyze the data of multi-spectral fluorescence imaging. Observed results of this pilot study highlight the advantages of proposed imaging technique for skin cancer diagnosis.

  19. Robot-assisted endoscope guidance versus manual endoscope guidance in functional endonasal sinus surgery (FESS).

    Science.gov (United States)

    Eichhorn, Klaus Wolfgang; Westphal, Ralf; Rilk, Markus; Last, Carsten; Bootz, Friedrich; Wahl, Friedrich; Jakob, Mark; Send, Thorsten

    2017-10-01

    Having one hand occupied with the endoscope is the major disadvantage for the surgeon when it comes to functional endoscopic sinus surgery (FESS). Only the other hand is free to use the surgical instruments. Tiredness or frequent instrument changes can thus lead to shaky endoscopic images. We collected the pose data (position and orientation) of the rigid 0° endoscope and all the instruments used in 16 FESS procedures with manual endoscope guidance as well as robot-assisted endoscope guidance. In combination with the DICOM CT data, we tracked the endoscope poses and workspaces using self-developed tracking markers. All surgeries were performed once with the robot and once with the surgeon holding the endoscope. Looking at the durations required, we observed a decrease in the operating time because one surgeon doing all the procedures and so a learning curve occurred what we expected. The visual inspection of the specimens showed no damages to any of the structures outside the paranasal sinuses. Robot-assisted endoscope guidance in sinus surgery is possible. Further CT data, however, are desirable for the surgical analysis of a tracker-based navigation within the anatomic borders. Our marker-based tracking of the endoscope as well as the instruments makes an automated endoscope guidance feasible. On the subjective side, we see that RASS brings a relief for the surgeon.

  20. COMPARISON OF MANUAL AND SEMIAUTOMATED FUNDUS AUTOFLUORESCENCE ANALYSIS OF MACULAR ATROPHY IN STARGARDT DISEASE PHENOTYPE.

    Science.gov (United States)

    Kuehlewein, Laura; Hariri, Amir H; Ho, Alexander; Dustin, Laurie; Wolfson, Yulia; Strauss, Rupert W; Scholl, Hendrik P N; Sadda, SriniVas R

    2016-06-01

    To evaluate manual and semiautomated grading techniques for assessing decreased fundus autofluorescence (DAF) in patients with Stargardt disease phenotype. Certified reading center graders performed manual and semiautomated (region finder-based) grading of confocal scanning laser ophthalmoscopy (cSLO) fundus autofluorescence (FAF) images for 41 eyes of 22 patients. Lesion types were defined based on the black level and sharpness of the border: definite decreased autofluorescence (DDAF), well, and poorly demarcated questionably decreased autofluorescence (WDQDAF, PDQDAF). Agreement in grading between the two methods and inter- and intra-grader agreement was assessed by kappa coefficients (κ) and intraclass correlation coefficients (ICC). The mean ± standard deviation (SD) area was 3.07 ± 3.02 mm for DDAF (n = 31), 1.53 ± 1.52 mm for WDQDAF (n = 9), and 6.94 ± 10.06 mm for PDQDAF (n = 17). The mean ± SD absolute difference in area between manual and semiautomated grading was 0.26 ± 0.28 mm for DDAF, 0.20 ± 0.26 mm for WDQDAF, and 4.05 ± 8.32 mm for PDQDAF. The ICC (95% confidence interval) for method comparison was 0.992 (0.984-0.996) for DDAF, 0.976 (0.922-0.993) for WDQDAF, and 0.648 (0.306-0.842) for PDQDAF. Inter- and intra-grader agreement in manual and semiautomated quantitative grading was better for DDAF (0.981-0.996) and WDQDAF (0.995-0.999) than for PDQDAF (0.715-0.993). Manual and semiautomated grading methods showed similar levels of reproducibility for assessing areas of decreased autofluorescence in patients with Stargardt disease phenotype. Excellent agreement and reproducibility were observed for well demarcated lesions.

  1. The Role of Adjunct Imaging in Endoscopic Detection of Dysplasia in Barrett's Esophagus.

    Science.gov (United States)

    Kandel, Pujan; Wallace, Michael B

    2017-07-01

    Advances in imaging technologies have demonstrated promise in early detection of dysplasia and cancer in Barrett's esophagus (BE). Optical chromoendoscopy, dye-based chromoendoscopy, and novel technologies have provided the opportunity to visualize the cellular and subcellular structures. Only narrow-band imaging and acetic acid chromoendoscopy have reached benchmarks for clinical use. Volumetric laser endomicroscopy and molecular imaging are not established for routine use. Best practice in management of BE should be focused on careful endoscopic examination, resection, or ablation of the entire abnormal lesion, as well as the use of available imaging technique that has good diagnostic accuracy. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Mirizzi Syndrome with Endoscopic Ultrasound Image

    Directory of Open Access Journals (Sweden)

    K. Rayapudi

    2013-05-01

    Full Text Available We describe a 66-year-old Caucasian man with type 1 Mirizzi syndrome diagnosed on endoscopic ultrasound. He presented with acute onset of jaundice, malaise, dark urine over 3-4 days, and was found to have obstructive jaundice on lab testing. CT scan of the abdomen showed intrahepatic biliary ductal dilation, a 1.5 cm common bile duct (CBD above the pancreas, and possible stones in the CBD, but no masses. Endoscopic retrograde cholangiopancreatography (ERCP by a community gastroenterologist failed to cannulate the CBD. At the University Center, type 1 Mirizzi syndrome was noted on endoscopic ultrasound with narrowing of the CBD with extrinsic compression from cystic duct stone. During repeat ERCP, the CBD could be cannulated over the pancreatic duct wire. A mid CBD narrowing, distal CBD stones, proximal CBD and extrahepatic duct dilation were noted, and biliary sphincterotomy was performed. A small stone in the distal CBD was removed with an extraction balloon. The cystic duct stone was moved with the biliary balloon into the CBD, mechanical basket lithotripsy was performed and stone fragments were delivered out with an extraction balloon. The patient was seen 7 weeks later in the clinic. Skin and scleral icterus had cleared up and he is scheduled for an elective cholecystectomy. Mirizzi syndrome refers to biliary obstruction resulting from impacted stone in the cystic duct or neck of the gallbladder and commonly presents with obstructive jaundice. Type 1 does not have cholecystocholedochal fistulas, but they present in types 2, 3 and 4. Surgery is the mainstay of therapy. Endoscopic treatment is effective and can also be used as a temporizing measure or definitive treatment in poor surgical risk candidates.

  3. Central serous chorioretinopathy fundus autofluorescence comparison with two different confocal scanning laser ophthalmoscopes.

    Science.gov (United States)

    Nam, Ki Tae; Yun, Cheol Min; Kim, Jee Taek; Yang, Kyung-Sook; Kim, Hyun Joo; Kim, Seong-Woo; Oh, Jaeryung; Huh, Kuhl

    2015-12-01

    To compare the lesion characteristics of two different types of confocal scanning laser ophthalmoscopy (cSLO) autofluorescence (AF) images in central serous chorioretinopathy (CSC). The study included 63 eyes of 61 patients; 63 pairs of fundus autofluorescence (FAF) images were compared before CSC resolution in 63 eyes, FAF images of 31 eyes were also compared after CSC resolution. The lesion characteristics (brightness and composite pattern) were compared between Heidelberg Retina Angiograph 2 (HRA2; Heidelberg Engineering, Germany) and Optomap Tx (Optomap; Optos, Scotland) FAF images. The lesion composite pattern was categorized as diffuse or granular. Diffuse AF was defined as homogenously increased or decreased AF, and granular AF was defined as dot-like, coarse changes in AF. The mean disease duration and subretinal fluid (SRF) height in the spectral domain optical coherence tomography were compared according to the FAF image characteristics. Lesion brightness before CSC resolution was hypo-AF in 48 eyes (76.2 %), hyper-AF in three (4.8 %), and mixed-AF in 12 (19.0 %) in HRA2 FAF images. In comparison, nine (14.3 %) images were hypo-AF, 44 (69.8 %) were hyper-AF, and 10 (15.9 %) were mixed-AF in Optomap FAF images (P < 0.0001). There was no significant difference in lesion composite pattern between the two FAF image wavelengths. Patients with lesions that were hyper-AF in Optomap FAF and hypo-AF in HRA2 FAF had a shorter disease duration and greater SRF height (1 month, 281 um) than those who were hyper-AF in both Optomap and HRA2 images (26 months, 153 um; P = 0.004, 0.001). The two types of FAF images of CSC showed different lesion brightness before and after CSC resolution but demonstrated similar lesion composite patterns.

  4. PATTERNS OF FUNDUS AUTOFLUORESCENCE DEFECTS IN NEOVASCULAR AGE-RELATED MACULAR DEGENERATION SUBTYPES.

    Science.gov (United States)

    Ozkok, Ahmet; Sigford, Douglas K; Tezel, Tongalp H

    2016-11-01

    To test define characteristic fundus autofluorescence patterns of different exudative age-related macular degeneration subtypes. Cross-sectional study. Fifty-two patients with choroidal neovascularization because of three different neovascular age-related macular degeneration subtypes were included in the study. Macular and peripheral fundus autofluorescence patterns of study subjects were compared in a masked fashion. Fundus autofluorescence patterns of all three neovascular age-related macular degeneration subtypes revealed similar patterns. However, peripapillary hypo-autofluorescence was more common among patients with polypoidal choroidal vasculopathy (88.2%) compared with patients with retinal angiomatous proliferation (12.5%) and patients without retinal angiomatous proliferation and polypoidal choroidal vasculopathy (21.1%) (P autofluorescence defects in neovascular age-related macular degeneration maybe suggestive of polypoidal choroidal vasculopathy as a variant of neovascular age-related macular degeneration.

  5. Novel computer-based endoscopic camera

    Science.gov (United States)

    Rabinovitz, R.; Hai, N.; Abraham, Martin D.; Adler, Doron; Nissani, M.; Fridental, Ron; Vitsnudel, Ilia

    1995-05-01

    We have introduced a computer-based endoscopic camera which includes (a) unique real-time digital image processing to optimize image visualization by reducing over exposed glared areas and brightening dark areas, and by accentuating sharpness and fine structures, and (b) patient data documentation and management. The image processing is based on i Sight's iSP1000TM digital video processor chip and Adaptive SensitivityTM patented scheme for capturing and displaying images with wide dynamic range of light, taking into account local neighborhood image conditions and global image statistics. It provides the medical user with the ability to view images under difficult lighting conditions, without losing details `in the dark' or in completely saturated areas. The patient data documentation and management allows storage of images (approximately 1 MB per image for a full 24 bit color image) to any storage device installed into the camera, or to an external host media via network. The patient data which is included with every image described essential information on the patient and procedure. The operator can assign custom data descriptors, and can search for the stored image/data by typing any image descriptor. The camera optics has extended zoom range of f equals 20 - 45 mm allowing control of the diameter of the field which is displayed on the monitor such that the complete field of view of the endoscope can be displayed on all the area of the screen. All these features provide versatile endoscopic camera with excellent image quality and documentation capabilities.

  6. Laser induced autofluorescence for diagnosis of non-melanoma skin cancer

    Science.gov (United States)

    Drakaki, E.; Makropoulou, M.; Serafetinides, A. A.; Merlemis, N.; Kalatzis, I.; Sianoudis, I. A.; Batsi, O.; Christofidou, E.; Stratigos, A. J.; Katsambas, A. D.; Antoniou, Ch.

    2015-01-01

    Non melanoma skin cancer is one of the most frequent malignant tumors among humans. A non-invasive technique, with high sensitivity and high specificity, would be the most suitable method for basal cell carcinoma (BCC) or other malignancies diagnostics, instead of the well established biopsy and histopathology examination. In the last decades, a non-invasive, spectroscopic diagnostic method was introduced, the laser induced fluorescence (LIF), which could generate an image contrast between different states of skin tissue. The noninvasiveness consists in that this biophotonic method do not require tissue sample excision, what is necessary in histopathology characterization and biochemical analysis of the skin tissue samples, which is worldwide used as an evaluation gold standard. The object of this study is to establish the possibilities of a relatively portable system for laser induced skin autofluorescence to differentiate malignant from nonmalignant skin lesions. Unstained human skin samples, excised from humans undergoing biopsy examination, were irradiated with a Nd:YAG-3ω laser (λ=355 nm, 6 ns), used as an excitation source for the autofluorescence measurements. A portable fiber-based spectrometer was used to record fluorescence spectra of the sites of interest. The ex vivo results, obtained with this spectroscopic technique, were correlated with the histopathology results. After the analysis of the fluorescence spectra of almost 60 skin tissue areas, we developed an algorithm to distinguish different types of malignant lesions, including inflammatory areas. Optimization of the data analysis and potential use of LIF spectroscopy with 355 nm Nd:YAG laser excitation of tissue autofluorescence for clinical applications are discussed.

  7. [Study of Image Quality Comparison Based on the MTF Method Between Different Medical Rigid Endoscopes in an In Vitro Model].

    Science.gov (United States)

    Wang, Yunlong; Ji, Jun; Jiang, Changsong; Huang, Zengyue

    2015-04-01

    This study was aimed to use the method of modulation transfer function (MTF) to compare image quality among three different Olympus medical rigid cystoscopes in an in vitro model. During the experimental processes, we firstly used three different types of cystoscopes (i. e. OLYMPUS cystourethroscopy with FOV of 12 degrees, OLYMPUS Germany A22003A and OLYMPUS A2013A) to collect raster images at different brightness with industrial camera and computer from the resolution target which is with different spatial frequency, and then we processed the collected images using MALAB software with the optical transfer function MTF to obtain the values of MTF at different brightness and different spatial frequency. We then did data mathematical statistics and compared imaging quality. The statistical data showed that all three MTF values were smaller than 1. MTF values with the spatial frequency gradually increasing would decrease approaching 0 at the same brightness. When the brightness enhanced in the same process at the same spatial frequency, MTF values showed a slowly increasing trend. The three endoscopes' MTF values were completely different. In some cases the MTF values had a large difference, and the maximum difference could reach 0.7. Conclusion can be derived from analysis of experimental data that three Olympus medical rigid cystoscopes have completely different imaging quality abilities. The No. 3 endoscope OLYMPUS A2013A has low resolution but high contrast. The No. 1 endoscope OLYMPUS cystourethroscopy with FOV of 12 degrees, on the contrary, had high resolution and lower contrast. The No. 2 endoscope OLYMPUS Germany A22003A had high contrast and high resolution, and its image quality was the best.

  8. Endoscopic inspection of steam turbines

    International Nuclear Information System (INIS)

    Maliniemi, H.; Muukka, E.

    1990-01-01

    For over ten years, Imatran Voima Oy (IVO) has developed, complementary inspection methods for steam turbine condition monitoring, which can be applied both during operation and shutdown. One important method used periodically during outages is endoscopic inspection. The inspection is based on the method where the internal parts of the turbine is inspected through access borings with endoscope and where the magnified figures of the internal parts is seen on video screen. To improve inspection assurance, an image-processing based pattern recognition method for cracks has been developed for the endoscopic inspection of turbine blades. It is based on the deduction conditions derived from the crack shape. The computer gives an alarm of a crack detection and prints a simulated image of the crack, which is then checked manually

  9. Application of laser-induced autofluorescence spectra detection in human colorectal cancer screening

    Science.gov (United States)

    Fu, Sheng; Chia, Teck-Chee; Kwek, Leong Chuan; Diong, Cheong Hoong; Tang, Choong Leong; Choen, Francis S.; Krishnan, S. M.

    2003-10-01

    We investigated 48 normal patients and 25 diseased patients using our laser-induced autofluorescence spectra detection system during their regular colonoscopy. The colon and rectum mucosa autofluorescence were excited by 405 nm continue wavelength laser. We observed that cancer or diseased colorectal mucosa, their autofluorescence spectra are significantly different from normal area. The autofluorescence spectra intensity at about 500 nm was been used for our intensity ratio characteristics intensity for our diagnostic algorithm. The intensity ratios of RI-680/I-500 and RI-630/I-500 were performed to identify the detection area. From experimental result we concluded that both intensity ratios of RI-680/I-500 and RI-630/I-500 as guidelines can detect cancerous and polyps disease completely. Our investigation provided some useful insight for laser induced autofluorescence spectra as a diagnosis technique for clinical application.

  10. Quantitative Fluorescence Sensing Through Highly Autofluorescent, Scattering, and Absorbing Media Using Mobile Microscopy

    KAUST Repository

    Gö rö cs, Zoltá n; Rivenson, Yair; Ceylan Koydemir, Hatice; Tseng, Derek; Troy, Tamara L.; Demas, Vasiliki; Ozcan, Aydogan

    2016-01-01

    Compact and cost-effective systems for in vivo fluorescence and near-infrared imaging in combination with activatable reporters embedded inside the skin to sample interstitial fluid or blood can enable a variety of biomedical applications. However, the strong autofluorescence of human skin creates an obstacle for fluorescence-based sensing. Here we introduce a method for quantitative fluorescence sensing through highly autofluorescent, scattering, and absorbing media. For this, we created a compact and cost-effective fluorescence microscope weighing <40 g and used it to measure various concentrations of a fluorescent dye embedded inside a tissue phantom, which was designed to mimic the optical characteristics of human skin. We used an elliptical Gaussian beam excitation to digitally separate tissue autofluorescence from target fluorescence, although they severely overlap in both space and optical spectrum. Using ∼10-fold less excitation intensity than the safety limit for skin radiation exposure, we successfully quantified the density of the embedded fluorophores by imaging the skin phantom surface and achieved a detection limit of ∼5 × 105 and ∼2.5 × 107 fluorophores within ∼0.01 μL sample volume that is positioned 0.5 and 2 mm below the phantom surface, corresponding to a concentration of 105.9 pg/mL and 5.3 ng/mL, respectively. We also confirmed that this approach can track the spatial misalignments of the mobile microscope with respect to the embedded target fluorescent volume. This wearable microscopy platform might be useful for designing implantable biochemical sensors with the capability of spatial multiplexing to continuously monitor a panel of biomarkers and chronic conditions even at patients’ home.

  11. Quantitative Fluorescence Sensing Through Highly Autofluorescent, Scattering, and Absorbing Media Using Mobile Microscopy

    KAUST Repository

    Göröcs, Zoltán

    2016-09-13

    Compact and cost-effective systems for in vivo fluorescence and near-infrared imaging in combination with activatable reporters embedded inside the skin to sample interstitial fluid or blood can enable a variety of biomedical applications. However, the strong autofluorescence of human skin creates an obstacle for fluorescence-based sensing. Here we introduce a method for quantitative fluorescence sensing through highly autofluorescent, scattering, and absorbing media. For this, we created a compact and cost-effective fluorescence microscope weighing <40 g and used it to measure various concentrations of a fluorescent dye embedded inside a tissue phantom, which was designed to mimic the optical characteristics of human skin. We used an elliptical Gaussian beam excitation to digitally separate tissue autofluorescence from target fluorescence, although they severely overlap in both space and optical spectrum. Using ∼10-fold less excitation intensity than the safety limit for skin radiation exposure, we successfully quantified the density of the embedded fluorophores by imaging the skin phantom surface and achieved a detection limit of ∼5 × 105 and ∼2.5 × 107 fluorophores within ∼0.01 μL sample volume that is positioned 0.5 and 2 mm below the phantom surface, corresponding to a concentration of 105.9 pg/mL and 5.3 ng/mL, respectively. We also confirmed that this approach can track the spatial misalignments of the mobile microscope with respect to the embedded target fluorescent volume. This wearable microscopy platform might be useful for designing implantable biochemical sensors with the capability of spatial multiplexing to continuously monitor a panel of biomarkers and chronic conditions even at patients’ home.

  12. FY1995 development of a endoscopic surgical system utilizing multi-modal functional images; 1995 nendo tashu kino gazo wo mochiiru teishinshu naishikyo shujutsu system no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-05-01

    The purpose of this study is to develop an endoscope system for neurosurgery that can provide not only conventional endoscopic images but also ultraviolet-visible spectra, fluorescence spectra, near infrared spectra, and ultra-soundimages of tissue aiming for real-time identification of pathological tissue. The system also incorporates surgical manipulator and devices such as micro forceps and laser surgical instruments for endoscopic image guided surgery. Surgical Manipulator should be a high performance and easy to operate surgical instrument as well as conventional surgical tools such as scissors and knife. Since living tissue deforms during surgical operation, pre-operative three dimensional information for registration of pathological tissue should be modified based on information obtained during surgery. Thus surgical manipulator should be operated under guidance of surgeon's observation. Consequently, surgical manipulator should have various types of imaging and measurement devices such as an endoscope and an ultrasound imaging probe at its end effectors. Based on this concept, a prototype of a new multi channel surgical manipulator system CM cube (CM3, Computer aided Micro Multichannel Manipulator) that has various types of imaging and measurement devices such as ultra-violet-visible camera for spectroscopic measurement, ultra-sound imaging probe, three dimensional endoscope, together with micro surgical instruments and laser surgical systems has been developed. Its performance was evaluated through in vitro/in vivo experiments and clinical application. (NEDO)

  13. Progression of Stargardt Disease as Determined by Fundus Autofluorescence in the Retrospective Progression of Stargardt Disease Study (ProgStar Report No. 9).

    Science.gov (United States)

    Strauss, Rupert W; Muñoz, Beatriz; Ho, Alexander; Jha, Anamika; Michaelides, Michel; Cideciyan, Artur V; Audo, Isabelle; Birch, David G; Hariri, Amir H; Nittala, Muneeswar G; Sadda, SriniVas; West, Sheila; Scholl, Hendrik P N

    2017-11-01

    Sensitive outcome measures for disease progression are needed for treatment trials of Stargardt disease. To describe the yearly progression rate of atrophic lesions in the retrospective Progression of Stargardt Disease study. A multicenter retrospective cohort study was conducted at tertiary referral centers in the United States and Europe. A total of 251 patients aged 6 years or older at baseline, harboring disease-causing variants in ABCA4 (OMIM 601691), enrolled in the study from 9 centers between August 2, 2013, and December 12, 2014; of these patients, 215 had at least 2 gradable fundus autofluorescence images with atrophic lesion(s) present in at least 1 eye. Areas of definitely decreased autofluorescence (DDAF) and questionably decreased autofluorescence were quantified by a reading center. Progression rates were estimated from linear mixed models with time as the independent variable. Yearly rate of progression using the growth of atrophic lesions measured by fundus autofluorescence. A total of 251 participants (458 study eyes) were enrolled. Images from 386 eyes of 215 participants (126 females and 89 males; mean [SD] age, 29.9 [14.7] years; mean [SD] age of onset of symptoms, 21.9 [13.3] years) showed atrophic lesions present on at least 2 visits and were graded for 2 (156 eyes), 3 (174 eyes), or 4 (57 eyes) visits. A subset of 224 eyes (123 female participants and 101 male participants; mean [SD] age, 33.0 [15.1] years) had areas of DDAF present on at least 2 visits; these eyes were included in the estimation of the progression of the area of DDAF. At the first visit, DDAF was present in 224 eyes (58.0%), with a mean (SD) lesion size of 2.2 (2.7) mm2. The total mean (SD) area of decreased autofluorescence (DDAF and questionably decreased autofluorescence) at first visit was 2.6 (2.8) mm2. Mean progression of DDAF was 0.51 mm2/y (95% CI, 0.42-0.61 mm2/y), and of total decreased fundus autofluorescence was 0.35 mm2/y (95% CI, 0.28-0.43 mm2/y). Rates of

  14. Wide-field phase imaging for the endoscopic detection of dysplasia and early-stage esophageal cancer

    Science.gov (United States)

    Fitzpatrick, C. R. M.; Gordon, G. S. D.; Sawyer, T. W.; Wilkinson, T. D.; Bohndiek, S. E.

    2018-02-01

    Esophageal cancer has a 5-year survival rate below 20%, but can be curatively resected if it is detected early. At present, poor contrast for early lesions in white light imaging leads to a high miss rate in standard-of- care endoscopic surveillance. Early lesions in the esophagus, referred to as dysplasia, are characterized by an abundance of abnormal cells with enlarged nuclei. This tissue has a different refractive index profile to healthy tissue, which results in different light scattering properties and provides a source of endogenous contrast that can be exploited for advanced endoscopic imaging. For example, point measurements of such contrast can be made with scattering spectroscopy, while optical coherence tomography generates volumetric data. However, both require specialist interpretation for diagnostic decision making. We propose combining wide-field phase imaging with existing white light endoscopy in order to provide enhanced contrast for dysplasia and early-stage cancer in an image format that is familiar to endoscopists. Wide-field phase imaging in endoscopy can be achieved using coherent illumination combined with phase retrieval algorithms. Here, we present the design and simulation of a benchtop phase imaging system that is compatible with capsule endoscopy. We have undertaken preliminary optical modelling of the phase imaging setup, including aberration correction simulations and an investigation into distinguishing between different tissue phantom scattering coefficients. As our approach is based on phase retrieval rather than interferometry, it is feasible to realize a device with low-cost components for future clinical implementation.

  15. The establishment of enteral nutrition with minimally-invasive interventional procedure under endoscopic or imaging guidance

    International Nuclear Information System (INIS)

    Li Feng; Cheng Yingsheng

    2010-01-01

    For patients unable to get the necessary nutrition orally, a variety of techniques,including surgical way, to make gastrostomy with tube placement have been employed. For recent years, gastrostomy and tube placement with the help of endoscopic guidance or percutaneous interventional management has been developed, which is superior to surgical procedure in minimizing injuries, decreasing cost and reducing complications. In certain clinical situations, both endoscopic method and interventional method can be employed. This paper aims to make a comprehensive review of the indications, techniques and skills, advantages and disadvantages of both the endoscopy-guided and the imaging-guided percutaneous gastrojejunostomy for the establishment of enteral nutrition. (authors)

  16. Retinal pigment epithelial changes in chronic Vogt-Koyanagi-Harada disease: fundus autofluorescence and spectral domain-optical coherence tomography findings.

    Science.gov (United States)

    Vasconcelos-Santos, Daniel V; Sohn, Elliott H; Sadda, Srinivas; Rao, Narsing A

    2010-01-01

    The purpose of this study was to determine whether fundus autofluorescence (FAF) and spectral domain-optical coherence tomography (SD-OCT) imaging allow better assessment of retinal pigment epithelium and the outer retina in subjects with chronic Vogt-Koyanagi-Harada disease compared with examination and angiography alone. A cross-sectional analysis of a series of seven consecutive patients with chronic Vogt-Koyanagi-Harada disease undergoing FAF and SD-OCT was conducted. Chronic disease was defined as duration of intraocular inflammation >3 months. Color fundus photographs were correlated to FAF and SD-OCT images. The images were later correlated to fluorescein angiography and indocyanine green angiography. All patients had sunset glow fundus, which resulted in no apparent corresponding abnormality on FAF or SD-OCT. Lesions with decreased autofluorescence signal were observed in 11 eyes (85%), being associated with loss of the retinal pigment epithelium and involvement of the outer retina on SD-OCT. In 5 eyes (38%), some of these lesions were very subtle on clinical examination but easily detected by FAF. Lesions with increased autofluorescence signal were seen in 8 eyes (61.5%), showing variable involvement of the outer retina on SD-OCT and corresponding clinically to areas of retinal pigment epithelium proliferation and cystoid macular edema. Combined use of FAF and SD-OCT imaging allowed noninvasive delineation of retinal pigment epithelium/outer retina changes in patients with chronic Vogt-Koyanagi-Harada disease, which were consistent with previous histopathologic reports. Some of these changes were not apparent on clinical examination.

  17. Role of Autofluorescence in Inflammatory/Infective Diseases of the Retina and Choroid

    OpenAIRE

    Samy, Ahmed; Lightman, Sue; Ismetova, Filis; Talat, Lazha; Tomkins-Netzer, Oren

    2014-01-01

    Fundus autofluorescence (FAF) has recently emerged as a novel noninvasive imaging technique that uses the fluorescent properties of innate fluorophores accumulated in the retinal pigment epithelium (RPE) to assess the health and viability of the RPE/photoreceptor complex. Recent case reports suggest FAF as a promising tool for monitoring eyes with posterior uveitis helping to predict final visual outcome. In this paper we review the published literature on FAF in these disorders, specifically...

  18. Systems workplace for endoscopic surgery.

    Science.gov (United States)

    Irion, K M; Novak, P

    2000-01-01

    With the advent of minimally invasive surgery (MIS) a decade ago, the requirements for operating rooms (OR) and their equipment have been increased. Compared with conventional open surgery, the new endoscopic techniques require additional tools. Television systems, for video-assisted image acquisition and visualisation, including cameras, monitors and light systems, as well as insufflators, pumps, high-frequency units, lasers and motorised therapy units, are nowadays usually made available on carts during endoscopic surgery. In conjunction with a set of endoscopic instruments, these high-tech units allow new operating techniques to be performed. The benefit for patients has become clear in recent years; however, the technical complexity of OR has also increased considerably. To minimise this problem for the OR personnel, the MIS concept 'OR1' (Operating Room 1) was developed and implemented. OR1 is a fully functional and integrated multi-speciality surgical suite for MIS. The centrepieces of the OR1 are the Storz Communication Bus (SCB) and the advanced image and data archiving system (Aida) from Karl Storz, Tuttlingen, Germany. Both components allow monitoring, access and networking of the MIS equipment and other OR facilities, as well as the acquisition, storage and display of image, patient and equipment data during the endoscopic procedure. A central user interface allows efficient, simplified operation and online clinical images. Due to the system integration, the handling of complex equipment is considerably simplified, logistical procedures in the OR are improved, procedure times are shorter and, particularly noteworthy, operative risk can be reduced through simplified device operation.

  19. Improving superficial target delineation in radiation therapy with endoscopic tracking and registration

    Energy Technology Data Exchange (ETDEWEB)

    Weersink, R. A.; Qiu, J.; Hope, A. J.; Daly, M. J.; Cho, B. C. J.; DaCosta, R. S.; Sharpe, M. B.; Breen, S. L.; Chan, H.; Jaffray, D. A. [Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario M5G 2M9 (Canada) and Ontario Cancer Institute, University Health Network, Toronto, Ontario M5G 2M9 (Canada); Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario M5G 2M9 (Canada); Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario M5G 2M9, Canada and Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario M5G 2M9 (Canada); Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario M5G 2M9 (Canada) and Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario M5G 2M9, Canada and Ontario Cancer Institute, University Health Network, Toronto, Ontario M5G 2M9 (Canada); Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario M5G 2M9 (Canada) and Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario M5G 2M9 (Canada); Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario M5G 2M9 (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5G 2M9 (Canada) and Ontario Cancer Institute, University Health Network, Toronto, Ontario M5G 2M9 (Canada)

    2011-12-15

    Purpose: Target delineation within volumetric imaging is a critical step in the planning process of intensity modulated radiation therapy. In endoluminal cancers, endoscopy often reveals superficial areas of visible disease beyond what is seen on volumetric imaging. Quantitatively relating these findings to the volumetric imaging is prone to human error during the recall and contouring of the target. We have developed a method to improve target delineation in the radiation therapy planning process by quantitatively registering endoscopic findings contours traced on endoscopic images to volumetric imaging. Methods: Using electromagnetic sensors embedded in an endoscope, 2D endoscopic images were registered to computed tomography (CT) volumetric images by tracking the position and orientation of the endoscope relative to a CT image set. Regions-of-interest (ROI) in the 2D endoscopic view were delineated. A mesh created within the boundary of the ROI was projected onto the 3D image data, registering the ROI with the volumetric image. This 3D ROI was exported to clinical radiation treatment planning software. The precision and accuracy of the procedure was tested on two solid phantoms with superficial markings visible on both endoscopy and CT images. The first phantom was T-shaped tube with X-marks etched on the interior. The second phantom was an anatomically correct skull phantom with a phantom superficial lesion placed on the pharyngeal surface. Markings were contoured on the endoscope images and compared with contours delineated in the treatment planning system based on the CT images. Clinical feasibility was tested on three patients with early stage glottic cancer. Image-based rendering using manually identified landmarks was used to improve the registration. Results: Using the T-shaped phantom with X-markings, the 2D to 3D registration accuracy was 1.5-3.5 mm, depending on the endoscope position relative to the markings. Intraobserver standard variation was 0

  20. Duodenal endoscopic findings and histopathologic confirmation of intestinal lymphangiectasia in dogs.

    Science.gov (United States)

    Larson, R N; Ginn, J A; Bell, C M; Davis, M J; Foy, D S

    2012-01-01

    The diagnosis of intestinal lymphangiectasia (IL) has been associated with characteristic duodenal mucosal changes. However, the sensitivity and specificity of the endoscopic duodenal mucosal appearance for the diagnosis of IL are not reported. To evaluate the utility of endoscopic images of the duodenum for diagnosis of IL. Endoscopic appearance of the duodenal mucosal might predict histopathologic diagnosis of IL with a high degree of sensitivity and specificity. 51 dogs that underwent upper gastrointestinal (GI) endoscopy and endoscopic biopsies. Retrospective review of images acquired during endoscopy. Dogs were included if adequate biopsies were obtained during upper GI endoscopy and digital images were saved during the procedure. Images were assessed for the presence and severity of IL. Using histopathology as the gold standard, the sensitivity and specificity of endoscopy for diagnosing IL were calculated. Intestinal lymphangiectasia (IL) was diagnosed in 25/51 dogs. Gross endoscopic appearance of the duodenal mucosa had a sensitivity and specificity (95% confidence interval) of 68% (46%, 84%) and 42% (24%, 63%), respectively for diagnosis of IL. Endoscopic images in cases with lymphopenia, hypocholesterolemia, and hypoalbuminemia had a sensitivity of 80%. Endoscopic duodenal mucosa appearance alone lacks specificity and has only a moderate sensitivity for diagnosis of IL. Evaluation of biomarkers associated with PLE improved the sensitivity; however, poor specificity for diagnosis of IL supports the need for histopathologic confirmation. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  1. Skin autofluorescence is associated with renal function and cardiovascular diseases in pre-dialysis chronic kidney disease patients.

    Science.gov (United States)

    Tanaka, Kenichi; Tani, Yoshihiro; Asai, Jun; Nemoto, Fumihiko; Kusano, Yuki; Suzuki, Hodaka; Hayashi, Yoshimitsu; Asahi, Koichi; Katoh, Tetsuo; Miyata, Toshio; Watanabe, Tsuyoshi

    2011-01-01

    Tissue accumulation of advanced glycation end-products (AGE) is thought to be a contributing factor to the progression of cardiovascular disease (CVD). Skin autofluorescence, a non-invasive measure of AGE accumulation using autofluorescence of the skin under ultraviolet light, has shown associations with CVD in haemodialysis patients. The present study aimed to evaluate relationships of skin autofluorescence to renal function as well as CVD in pre-dialysis patients with chronic kidney disease (CKD). Subjects in this cross-sectional analysis comprised 304 pre-dialysis CKD patients [median age, 62.0 years; median estimated glomerular filtration rate (eGFR), 54.3 mL/min/1.73 m(2); diabetes, n = 81 (26.6%)]. AGE accumulation in skin was assessed by skin autofluorescence using an autofluorescence reader. Relationships between skin autofluorescence, eGFR, CVD history and other parameters were evaluated. Skin autofluorescence correlated negatively with eGFR (r = -0.42, P skin autofluorescence with age, presence of diabetes, eGFR and CVD history in CKD patients (R(2) = 30%). Age, male gender, smoking history, skin autofluorescence and eGFR were significantly correlated with CVD history, and multiple logistic regression analysis identified age [odds ratio (OR), 1.09; 95% confidence interval (CI), 1.03-1.15; P skin autofluorescence (OR, 3.74; 95%CI, 1.54-9.24; P skin autofluorescence increased as GFR decreased and was related to CVD history in CKD patients. Non-invasive autofluorescence readers may provide potential markers for clinical risk assessment in pre-dialysis CKD patients.

  2. Identification of endogenous fluorophores in the photoreceptors using autofluorescence spectroscopy

    Science.gov (United States)

    Zhao, Lingling; Qu, Junle; Niu, Hanben

    2007-11-01

    In this paper, we present our investigation on the identification of endogenous fluorophores in photoreceptors using autofluorescence spectroscopy, which is performed with an inverted laser scanning confocal microscope equipped with an Argon ion laser and a GreNe laser. In our experiments, individual cones and rods are clearly resolved even in freshly prepared retina samples, without slicing or labeling. The experiment results show that autofluorescence spectrum of the photoreceptors has three peaks approximately at 525nm, 585nm and 665nm. Furthermore, the brightest autofluorescence originates from the photoreceptor outer segments. We can, therefore, come to a conclusion that the peaks at 525nm, 585nm are corresponding to FAD and A2-PE, respectively, which are distributed in the photoreceptor outer segments.

  3. Study on multi-detector computed tomography in the virtual endoscope mode to phantom of saliva gland duct application. Image quality evaluation of geometry

    International Nuclear Information System (INIS)

    Ozawa, Tomonori; Innami, Hisashi; Oyake, Reira; Shinohara, Yuki; Yamaaki, Fumi; Koizumi, Nobuhide; Okumura, Yasuhiko

    2009-01-01

    The diagnosis ability of the radiographic imaging has been greatly improved by the advent of multi-detector computed tomography (MDCT), Which is now a the prerequisite to the diagnosis and treatment of a variety of diseases. MDCT conducted in the virtual endoscope mode can be used for various image compositions, and the space in a structure such as the large intestines can be visualized similarly as with an actual endoscope. Using a phantom of a salivary gland duct, I performed the image analysis to determine whether this endoscope mode could able to be applied to the oral cavity. I searched for the optimum conditions and the best position for taking pictures, and evaluated whether the salivary gland ducts could be reproducibly imitated by the phantom. Modulation transfer function (MTF), Wiener spectrum (WS) analysis were used to examined the utility of MDCT in the virtual endoscope mode for use in the oral cavity. As a result, the following conclusions were made: The best image was obtained within 40 mm from the center part of the gantry by the MTF and the WS analyses. Decreases in the MTF and the WS as the decrease were seen at 20 mAs and 80 kV, and the decrease were seen in the sharpness of the image decreased as the value of the reconstruction function became smaller. The image was somewhat distorted when pictures were taken of the parallel or the direction of the slice by the inclination within 90 deg±15 deg as much as possible Z axially for running of the duct in the evaluation of internal reproducibility. The influence was admitted to go out easily in an inside form as the inside diameter became thin. The salivary gland phantom was evaluated geometrically by MDCT in the virtual endoscope mode, and the optimal conditions were obtained from the above-mentioned results. The utility of MDCT in the mode was thus suggested. (author)

  4. Autofluorescence lifetime metrology for label-free detection of cartilage matrix degradation

    Science.gov (United States)

    Nickdel, Mohammad B.; Lagarto, João. L.; Kelly, Douglas J.; Manning, Hugh B.; Yamamoto, Kazuhiro; Talbot, Clifford B.; Dunsby, Christopher; French, Paul; Itoh, Yoshifumi

    2014-03-01

    Degradation of articular cartilage extracellular matrix (ECM) by proteolytic enzyme is the hallmark of arthritis that leads to joint destruction. Detection of early biochemical changes in cartilage before irreversible structural damages become apparent is highly desirable. Here we report that the autofluorescence decay profile of cartilage is significantly affected by proteolytic degradation of cartilage ECM and can be characterised by measurements of the autofluorescence lifetime (AFL). A multidimensional fluorometer utilizing ultraviolet excitation at 355 nm or 375 nm coupled to a fibreoptic probe was developed for single point time-resolved AFL measurements of porcine articular cartilage explants treated with different proteinases. Degradation of cartilage matrix components by treating with bacterial collagenase, matrix metalloproteinase 1, or trypsin resulted in significant reduction of AFL of the cartilage in both a dose and time dependent manner. Differences in cartilage AFL were also confirmed by fluorescence lifetime imaging microscopy (FLIM). Our data suggest that AFL of cartilage tissue is a potential non-invasive readout to monitor cartilage matrix integrity that may be utilized for diagnosis of arthritis as well as monitoring the efficacy of anti-arthritic therapeutic agents.

  5. Endoscopic trans-nasal approach for biopsy of orbital tumors using image-guided neuro-navigation system

    International Nuclear Information System (INIS)

    Sieskiewicz, A.; Mariak, Z.; Rogowski, M.; Lyson, T.

    2008-01-01

    Histopathological diagnosis of intraorbital tumors is of crucial value for planning further therapy. The aim of the study was to explore clinical utility of image-guided endoscopy for biopsy of orbital tumors. Trans-nasal endoscopic biopsy of intraorbital mass lesions was performed in 6 patients using a neuro-navigation system (Medtronic Stealth Station Treon plus). The CT and MRI 1 mm slice images were fused by the system in order to visualise both bony and soft tissue structures. The anatomic fiducial registration protocol was used during the procedure. All lesions were precisely localised and the biopsies could be taken from the representative part of the pathological mass. None of the patients developed aggravation of ocular symptoms after the procedure. The operative corridor as well as the size of orbital wall fenestration could be limited to a minimum. The accuracy of neuro-navigation remained high and stable during the entire procedure. The image-guided neuro-navigation system facilitated endoscopic localisation and biopsy of intraorbital tumors and contributed to the reduction of surgical trauma during the procedure. The technique was particularly useful in small, medially located, retrobulbar tumors and in unclear situations when the structure of the lesion resembled surrounding intraorbital tissue. (author)

  6. Quantitative Characteristics of Spectral-Domain Optical Coherence Tomography in Corresponding Areas of Increased Autofluorescence at the Margin of Geographic Atrophy in Patients With Age-Related Macular Degeneration.

    Science.gov (United States)

    Hariri, Amir H; Nittala, Muneeswar G; Sadda, SriniVas R

    2016-06-01

    To evaluate the spectral-domain optical coherence tomography (SD-OCT) characteristics of the junctional zone corresponding to areas of increased autofluorescence (IAF) at the margin of geographic atrophy (GA) in patients with age-related macular degeneration (AMD). SD-OCT and fundus autofluorescence (FAF) images from untreated eyes with GA available from archived studies at Doheny Image Reading Center were evaluated. Areas of definite decreased autofluorescence (DDAF) corresponding to GA, and areas of IAF at the margins of the GA were manually segmented. Eyes with evidence of IAF were selected. Following manual registration of FAF and OCT data, areas of IAF and normal fluorescence were correlated with OCT features at these locations. Thirty eyes were included. The mean retinal pigment epithelium (RPE) thickness in areas of IAF was 40.6 µm ± 7.69 µm, compared to 28.8 µm ± 7.09 µm in normal adjacent areas (P Retina. 2016;47:523-527.]. Copyright 2016, SLACK Incorporated.

  7. Fundus Autofluorescence and Spectral Domain OCT in Central Serous Chorioretinopathy

    Directory of Open Access Journals (Sweden)

    Luiz Roisman

    2011-01-01

    Full Text Available Background. To describe the standard autofluorescence (FAF, the near infrared autofluorescence (NIA and optical coherence tomography (OCT patterns in central serous chorioretinopathy, correlating them with fluorescein angiography. Methods. Cross-sectional observational study, in which patients with at least seven months of CSC underwent ophthalmologic examination, fundus photography, FAF, NIA, fluorescein angiography (FA, and spectral-domain OCT. Results. Seventeen eyes of thirteen patients were included. The presentation features were a mottled hyperFAF in the detached area and areas with pigment mottling. NIA images showed areas of hyperNIA similar to FAF and localized areas of hypoNIA, which correlated with the points of leakage in the FA. OCT showed pigment epithelium detachment at the location of these hypoNIA spots. Discussion. FAF showed increased presence of fluorophores in the area of retinal detachment, which is believed to appear secondary to lipofuscin accumulation in the RPE or the presence of debris in the subretinal fluid. NIA has been related to the choroidal melanin content and there were areas of both increased and decreased NIA, which could be explained by damage ahead the retina, basically RPE and choroid. These findings, along with the PEDs found in the areas of hypoNIA, support the notion of a primary choroidal disease in CSC.

  8. Design of Endoscopic Capsule With Multiple Cameras.

    Science.gov (United States)

    Gu, Yingke; Xie, Xiang; Li, Guolin; Sun, Tianjia; Wang, Dan; Yin, Zheng; Zhang, Pengfei; Wang, Zhihua

    2015-08-01

    In order to reduce the miss rate of the wireless capsule endoscopy, in this paper, we propose a new system of the endoscopic capsule with multiple cameras. A master-slave architecture, including an efficient bus architecture and a four level clock management architecture, is applied for the Multiple Cameras Endoscopic Capsule (MCEC). For covering more area of the gastrointestinal tract wall with low power, multiple cameras with a smart image capture strategy, including movement sensitive control and camera selection, are used in the MCEC. To reduce the data transfer bandwidth and power consumption to prolong the MCEC's working life, a low complexity image compressor with PSNR 40.7 dB and compression rate 86% is implemented. A chipset is designed and implemented for the MCEC and a six cameras endoscopic capsule prototype is implemented by using the chipset. With the smart image capture strategy, the coverage rate of the MCEC prototype can achieve 98% and its power consumption is only about 7.1 mW.

  9. MULTIMODAL IMAGING OF DISEASE-ASSOCIATED PIGMENTARY CHANGES IN RETINITIS PIGMENTOSA.

    Science.gov (United States)

    Schuerch, Kaspar; Marsiglia, Marcela; Lee, Winston; Tsang, Stephen H; Sparrow, Janet R

    2016-12-01

    Using multiple imaging modalities, we evaluated the changes in photoreceptor cells and retinal pigment epithelium (RPE) that are associated with bone spicule-shaped melanin pigmentation in retinitis pigmentosa. In a cohort of 60 patients with retinitis pigmentosa, short-wavelength autofluorescence, near-infrared autofluorescence (NIR-AF), NIR reflectance, spectral domain optical coherence tomography, and color fundus images were studied. Central AF rings were visible in both short-wavelength autofluorescence and NIR-AF images. Bone spicule pigmentation was nonreflective in NIR reflectance, hypoautofluorescent with short-wavelength autofluorescence and NIR-AF imaging, and presented as intraretinal hyperreflective foci in spectral domain optical coherence tomography images. In areas beyond the AF ring outer border, the photoreceptor ellipsoid zone band was absent in spectral domain optical coherence tomography and the visibility of choroidal vessels in short-wavelength autofluorescence, NIR-AF, and NIR reflectance images was indicative of reduced RPE pigmentation. Choroidal visibility was most pronounced in the zone approaching peripheral areas of bone spicule pigmentation; here RPE/Bruch membrane thinning became apparent in spectral domain optical coherence tomography. These findings are consistent with a process by which RPE cells vacate their monolayer and migrate into inner retina in response to photoreceptor cell degeneration. The remaining RPE spread undergo thinning and consequently become less pigmented. An explanation for the absence of NIR-AF melanin signal in relation to bone spicule pigmentation is not forthcoming.

  10. MR imaging of colorectal carcinomas using an MR endoscopic coil

    International Nuclear Information System (INIS)

    Murano, Akihiko; Kido, Choichiro; Sasaki, Fumio; Nakamura, Tsuneya; Kobayashi, Semi; Katoh, Tomoyuki; Hirai, Takashi

    1994-01-01

    Diagnosis of the depth of wall invasion by rectal carcinoma using MR endoscopy was performed in ten resected specimens, including five rectal carcinomas, three colon carcinomas, two normal gastric wall. In addition, the gastric wall of a pig was examined. MR imaging was done with a 1.5-T Signa Advantage (GE Medical System) system, with the surface coil of the MR endoscope acting as the receiver coil. Five layers could be distinguished in the bowel wall: mucosa, submucosa and muscularis propria divided into circular muscle, longitudinal muscle and intervening connective tissue. Tumors had almost the same signal intensity as muscle. The MR images of colon carcinomas, rectal carcinomas, and extrinsically metastatic involvement of the sigmoid colon by rectal carcinoma all correlated well with the pathological findings. The normal structure of the gastric wall was similar to that of the colon. 3D-fast Spoiled Grass (SPGR) sequence has a fairly short scanning time. Thus, the possibility of precise clinical diagnosis by this method was suggested. (author)

  11. Drusen regression is associated with local changes in fundus autofluorescence in intermediate age-related macular degeneration.

    Science.gov (United States)

    Toy, Brian C; Krishnadev, Nupura; Indaram, Maanasa; Cunningham, Denise; Cukras, Catherine A; Chew, Emily Y; Wong, Wai T

    2013-09-01

    To investigate the association of spontaneous drusen regression in intermediate age-related macular degeneration (AMD) with changes on fundus photography and fundus autofluorescence (FAF) imaging. Prospective observational case series. Fundus images from 58 eyes (in 58 patients) with intermediate AMD and large drusen were assessed over 2 years for areas of drusen regression that exceeded the area of circle C1 (diameter 125 μm; Age-Related Eye Disease Study grading protocol). Manual segmentation and computer-based image analysis were used to detect and delineate areas of drusen regression. Delineated regions were graded as to their appearance on fundus photographs and FAF images, and changes in FAF signal were graded manually and quantitated using automated image analysis. Drusen regression was detected in approximately half of study eyes using manual (48%) and computer-assisted (50%) techniques. At year-2, the clinical appearance of areas of drusen regression on fundus photography was mostly unremarkable, with a majority of eyes (71%) demonstrating no detectable clinical abnormalities, and the remainder (29%) showing minor pigmentary changes. However, drusen regression areas were associated with local changes in FAF that were significantly more prominent than changes on fundus photography. A majority of eyes (64%-66%) demonstrated a predominant decrease in overall FAF signal, while 14%-21% of eyes demonstrated a predominant increase in overall FAF signal. FAF imaging demonstrated that drusen regression in intermediate AMD was often accompanied by changes in local autofluorescence signal. Drusen regression may be associated with concurrent structural and physiologic changes in the outer retina. Published by Elsevier Inc.

  12. Color reproduction and processing algorithm based on real-time mapping for endoscopic images.

    Science.gov (United States)

    Khan, Tareq H; Mohammed, Shahed K; Imtiaz, Mohammad S; Wahid, Khan A

    2016-01-01

    In this paper, we present a real-time preprocessing algorithm for image enhancement for endoscopic images. A novel dictionary based color mapping algorithm is used for reproducing the color information from a theme image. The theme image is selected from a nearby anatomical location. A database of color endoscopy image for different location is prepared for this purpose. The color map is dynamic as its contents change with the change of the theme image. This method is used on low contrast grayscale white light images and raw narrow band images to highlight the vascular and mucosa structures and to colorize the images. It can also be applied to enhance the tone of color images. The statistic visual representation and universal image quality measures show that the proposed method can highlight the mucosa structure compared to other methods. The color similarity has been verified using Delta E color difference, structure similarity index, mean structure similarity index and structure and hue similarity. The color enhancement was measured using color enhancement factor that shows considerable improvements. The proposed algorithm has low and linear time complexity, which results in higher execution speed than other related works.

  13. NEAR-INFRARED AUTOFLUORESCENCE IN BILATERAL DIFFUSE UVEAL MELANOCYTIC PROLIFERATION ASSOCIATED WITH ESOPHAGEAL CARCINOMA AND CHOROIDAL METASTASIS.

    Science.gov (United States)

    Golshahi, Azadeh; Bornfeld, Norbert; Weinitz, Silke; Kellner, Ulrich

    2016-01-01

    To investigate the advantage of near-infrared autofluorescence (787 nm) for the detection of melanocytic lesions in a patient with bilateral diffuse uveal melanocytic proliferation in association with esophageal carcinoma complicated by most likely unilateral choroidal metastasis. In this retrospective case report, a 55-year-old woman referred for the evaluation of sudden visual loss underwent normal ophthalmological evaluation and, in addition, was examined with near-infrared reflectance, near-infrared autofluorescence, fundus autofluorescence (Heidelberg Retina Angiograph II [HRA2; Heidelberg Engineering]), spectral domain optical coherence tomography (Spectralis OCT; Heidelberg Engineering), and multifocal electroretinography (RetiScan; Roland Consult). The patient had been diagnosed with esophageal carcinoma 3 months before the onset of visual symptoms. The visual acuity was 20/40 in the right eye and 20/20 in the left eye. Bilateral patchy melanocytic proliferation was detected on ophthalmoscopy. The extent of lesions was best detected with near-infrared reflectance and near-infrared autofluorescence, whereas fundus autofluorescence and spectral domain optical coherence tomography did not reveal alterations of the outer retina or retinal pigment epithelium in this early stage of bilateral diffuse uveal melanocytic proliferation. The right eye showed in addition to the findings on the left eye choroidal folds in the fovea and an elevated lesion inferotemporal of the fovea suspicious of a choroidal metastasis. In the B-scan ultrasonography, a homogenous lesion was seen. Spectral domain optical coherence tomography demonstrated a mild accumulation of subretinal fluid adjacent to and over the choroidal metastasis. Transretinal biopsy of this elevated lesion revealed a low differentiated carcinoma of squamous epithelium, compatible with choroidal metastasis of the esophageal carcinoma. The choroidal metastasis increased within 3 months after the first visit. The

  14. Physical limits to autofluorescence signals in vivo recordings in the rat olfactory bulb: a Monte Carlo study

    Science.gov (United States)

    L'Heureux, B.; Gurden, H.; Pinot, L.; Mastrippolito, R.; Lefebvre, F.; Lanièce, P.; Pain, F.

    2007-07-01

    Understanding the cellular mechanisms of energy supply to neurons following physiological activation is still challenging and has strong implications to the interpretation of clinical functional images based on metabolic signals such as Blood Oxygen Level Dependent Magnetic Resonance Imaging or 18F-Fluorodexoy-Glucose Positron Emission Tomography. Intrinsic Optical Signal Imaging provides with high spatio temporal resolution in vivo imaging in the anaesthetized rat. In that context, intrinsic signals are mainly related to changes in the optical absorption of haemoglobin depending on its oxygenation state. This technique has been validated for imaging of the rat olfactory bulb, providing with maps of the actived olfactory glomeruli, the functional modules involved in the first step of olfactory coding. A complementary approach would be autofluorescence imaging relying on the fluorescence properties of endogenous Flavin Adenine Dinucleotide (FAD) or Nicotinamide Adenine Dinucleotide (NADH) both involved in intracellular metabolic pathways. The purpose of the present study was to investigate the feasibility of in vivo autofluorescence imaging in the rat olfactory bulb. We performed standard Monte Carlo simulations of photons scattering and absorption at the excitation and emission wavelengths of FAD and NADH fluorescence. Characterization of the fluorescence distribution in the glomerulus, effect of hemoglobin absorption at the excitation and absorption wavelengths as well as the effect of the blurring due to photon scattering and the depth of focus of the optical apparatus have been studied. Finally, optimal experimental parameters are proposed to achieve in vivo validation of the technique in the rat olfactory bulb.

  15. New flexible endoscope for otologic application

    Science.gov (United States)

    Marchan, Mark L.

    1993-07-01

    Endoscopy has become an important procedure in many medical specialties. For the Otologist, however, space limitations within the ear have restricted development of endoscopic procedures. The desire for minimally invasive techniques in Otology has demonstrated itself through the work of numerous physicians who have performed procedures ranging from diagnostic inspection of the middle ear to viewing the interior of the cochlea. To assist in performing such endoscopic procedures, Xomed-Treace has developed a line of flexible fiberoptic endoscopes for use by the Otologist. These scopes combine illumination and imaging fiber bundles within a small diameter unit ranging in size from 0.8 mm to 1.2 mm. The 1.2 mm scope is produced with an angled, rigid stainless steel sheath. The 0.8 mm scope is flexible with the ability to articulate 120 degree(s) in one direction. The fiberscopes have been designed for the Otologist to produce a good resolution image while allowing ease of operation through ergonomics and consideration of the surgical anatomy.

  16. Role of autofluorescence in inflammatory/infective diseases of the retina and choroid.

    Science.gov (United States)

    Samy, Ahmed; Lightman, Sue; Ismetova, Filis; Talat, Lazha; Tomkins-Netzer, Oren

    2014-01-01

    Fundus autofluorescence (FAF) has recently emerged as a novel noninvasive imaging technique that uses the fluorescent properties of innate fluorophores accumulated in the retinal pigment epithelium (RPE) to assess the health and viability of the RPE/photoreceptor complex. Recent case reports suggest FAF as a promising tool for monitoring eyes with posterior uveitis helping to predict final visual outcome. In this paper we review the published literature on FAF in these disorders, specifically patterns in infectious and noninfectious uveitis, and illustrate some of these with short case histories.

  17. Role of Autofluorescence in Inflammatory/Infective Diseases of the Retina and Choroid

    Directory of Open Access Journals (Sweden)

    Ahmed Samy

    2014-01-01

    Full Text Available Fundus autofluorescence (FAF has recently emerged as a novel noninvasive imaging technique that uses the fluorescent properties of innate fluorophores accumulated in the retinal pigment epithelium (RPE to assess the health and viability of the RPE/photoreceptor complex. Recent case reports suggest FAF as a promising tool for monitoring eyes with posterior uveitis helping to predict final visual outcome. In this paper we review the published literature on FAF in these disorders, specifically patterns in infectious and noninfectious uveitis, and illustrate some of these with short case histories.

  18. Application of phase-contrast cine magnetic resonance imaging in endoscopic aqueductoplasty.

    Science.gov (United States)

    Chen, Guoqiang; Zheng, Jiaping; Xiao, Qing; Liu, Yunsheng

    2013-06-01

    The aim of this study was to evaluate the application of phase-contrast cine magnetic resonance imaging (MRI) in endoscopic aqueductoplasty (EA) for patients with obstructive hydrocephalus. The clinical diagnosis of hydrocephalus caused by aqueduct obstruction in 23 patients was confirmed by phase-contrast cine MRI examination. The patients were treated with EA and MRI was repeated during the follow-up. The cerebrospinal fluid (CSF) flow velocity in the aqueduct was measured to determine whether the aqueduct was obstructed. The results of phase-contrast cine MRI examinations indicated that there was no CSF flow in the aqueduct for all patients prior to surgery. Aqueductoplasty was successfully performed in all patients. The results of phase-contrast cine MRI examinations performed a week after surgery demonstrated an average CSF flow velocity of 4.74±1.77 cm/sec. During the follow-up, intracranial hypertension recurred in two patients in whom CSF flow was not observed in the aqueduct by the phase-contrast cine MRI scan. Aqueduct re-occlusion was revealed by an endoscopic exploration. By measuring the CSF flow velocity, phase-contrast cine MRI accurately identifies aqueduct obstruction. Cine MRI is a nontraumatic, simple and reliable method for determining whether the aqueduct is successfully opened following aqueductoplasty.

  19. In vivo imaging of the retinal pigment epithelial cells

    Science.gov (United States)

    Morgan, Jessica Ijams Wolfing

    The retinal pigment epithelial (RPE) cells form an important layer of the retina because they are responsible for providing metabolic support to the photoreceptors. Techniques to image the RPE layer include autofluorescence imaging with a scanning laser ophthalmoscope (SLO). However, previous studies were unable to resolve single RPE cells in vivo. This thesis describes the technique of combining autofluorescence, SLO, adaptive optics (AO), and dual-wavelength simultaneous imaging and registration to visualize the individual cells in the RPE mosaic in human and primate retina for the first time in vivo. After imaging the RPE mosaic non-invasively, the cell layer's structure and regularity were characterized using quantitative metrics of cell density, spacing, and nearest neighbor distances. The RPE mosaic was compared to the cone mosaic, and RPE imaging methods were confirmed using histology. The ability to image the RPE mosaic led to the discovery of a novel retinal change following light exposure; 568 nm exposures caused an immediate reduction in autofluorescence followed by either full recovery or permanent damage in the RPE layer. A safety study was conducted to determine the range of exposure irradiances that caused permanent damage or transient autofluorescence reductions. Additionally, the threshold exposure causing autofluorescence reduction was determined and reciprocity of radiant exposure was confirmed. Light exposures delivered by the AOSLO were not significantly different than those delivered by a uniform source. As all exposures tested were near or below the permissible light levels of safety standards, this thesis provides evidence that the current light safety standards need to be revised. Finally, with the retinal damage and autofluorescence reduction thresholds identified, the methods of RPE imaging were modified to allow successful imaging of the individual cells in the RPE mosaic while still ensuring retinal safety. This thesis has provided a

  20. Hybrid model based unified scheme for endoscopic Cerenkov and radio-luminescence tomography: Simulation demonstration

    Science.gov (United States)

    Wang, Lin; Cao, Xin; Ren, Qingyun; Chen, Xueli; He, Xiaowei

    2018-05-01

    Cerenkov luminescence imaging (CLI) is an imaging method that uses an optical imaging scheme to probe a radioactive tracer. Application of CLI with clinically approved radioactive tracers has opened an opportunity for translating optical imaging from preclinical to clinical applications. Such translation was further improved by developing an endoscopic CLI system. However, two-dimensional endoscopic imaging cannot identify accurate depth and obtain quantitative information. Here, we present an imaging scheme to retrieve the depth and quantitative information from endoscopic Cerenkov luminescence tomography, which can also be applied for endoscopic radio-luminescence tomography. In the scheme, we first constructed a physical model for image collection, and then a mathematical model for characterizing the luminescent light propagation from tracer to the endoscopic detector. The mathematical model is a hybrid light transport model combined with the 3rd order simplified spherical harmonics approximation, diffusion, and radiosity equations to warrant accuracy and speed. The mathematical model integrates finite element discretization, regularization, and primal-dual interior-point optimization to retrieve the depth and the quantitative information of the tracer. A heterogeneous-geometry-based numerical simulation was used to explore the feasibility of the unified scheme, which demonstrated that it can provide a satisfactory balance between imaging accuracy and computational burden.

  1. Quantitative analysis of myocardial tissue with digital autofluorescence microscopy

    Directory of Open Access Journals (Sweden)

    Thomas Jensen

    2016-01-01

    Full Text Available Background: The opportunity offered by whole slide scanners of automated histological analysis implies an ever increasing importance of digital pathology. To go beyond the importance of conventional pathology, however, digital pathology may need a basic histological starting point similar to that of hematoxylin and eosin staining in conventional pathology. This study presents an automated fluorescence-based microscopy approach providing highly detailed morphological data from unstained microsections. This data may provide a basic histological starting point from which further digital analysis including staining may benefit. Methods: This study explores the inherent tissue fluorescence, also known as autofluorescence, as a mean to quantitate cardiac tissue components in histological microsections. Data acquisition using a commercially available whole slide scanner and an image-based quantitation algorithm are presented. Results: It is shown that the autofluorescence intensity of unstained microsections at two different wavelengths is a suitable starting point for automated digital analysis of myocytes, fibrous tissue, lipofuscin, and the extracellular compartment. The output of the method is absolute quantitation along with accurate outlines of above-mentioned components. The digital quantitations are verified by comparison to point grid quantitations performed on the microsections after Van Gieson staining. Conclusion: The presented method is amply described as a prestain multicomponent quantitation and outlining tool for histological sections of cardiac tissue. The main perspective is the opportunity for combination with digital analysis of stained microsections, for which the method may provide an accurate digital framework.

  2. Secondary Metabolite Localization by Autofluorescence in Living Plant Cells

    Directory of Open Access Journals (Sweden)

    Pascale Talamond

    2015-03-01

    Full Text Available Autofluorescent molecules are abundant in plant cells and spectral images offer means for analyzing their spectra, yielding information on their accumulation and function. Based on their fluorescence characteristics, an imaging approach using multiphoton microscopy was designed to assess localization of the endogenous fluorophores in living plant cells. This method, which requires no previous treatment, provides an effective experimental tool for discriminating between multiple naturally-occurring fluorophores in living-tissues. Combined with advanced Linear Unmixing, the spectral analysis extends the possibilities and enables the simultaneous detection of fluorescent molecules reliably separating overlapping emission spectra. However, as with any technology, the possibility for artifactual results does exist. This methodological article presents an overview of the applications of tissular and intra-cellular localization of these intrinsic fluorophores in leaves and fruits (here for coffee and vanilla. This method will provide new opportunities for studying cellular environments and the behavior of endogenous fluorophores in the intracellular environment.

  3. Essential pre-treatment imaging examinations in patients with endoscopically-diagnosed early gastric cancer

    Directory of Open Access Journals (Sweden)

    Tokunaga Mari

    2010-06-01

    Full Text Available Abstract Background There have been no reports discussing which imaging procedures are truly necessary before treatment of endoscopically-diagnosed early gastric cancer (eEGC. The aim of this pilot study was to show which imaging examinations are essential to select indicated treatment or appropriate strategy in patients with eEGC. Methods In 140 consecutive patients (95 men, 45 women; age, 66.4 +/- 11.3 years [mean +/- standard deviation], range, 33-90 with eEGC which were diagnosed during two years, the pre-treatment results of ultrasonography (US and contrast-enhanced computed tomography (CT of the abdomen, barium enema (BE and chest radiography (CR were retrospectively reviewed. Useful findings that might affect indication or strategy were evaluated. Results US demonstrated useful findings in 13 of 140 patients (9.3%: biliary tract stones (n = 11 and other malignant tumors (n = 2. Only one useful finding was demonstrated on CT (pancreatic intraductal papillary mucinous tumor but not on US (0.7%; 95% confidential interval [CI], 2.1%. BE demonstrated colorectal carcinomas in six patients and polyps in 10 patients, altering treatment strategy (11.4%; 95%CI, 6.1-16.7%. Of these, only two colorectal carcinomas were detected on CT. CR showed three relevant findings (2.1%: pulmonary carcinoma (n = 1 and cardiomegaly (n = 2. Seventy-nine patients (56% were treated surgically and 56 patients were treated by endoscopic intervention. The remaining five patients received no treatment due to various reasons. Conclusions US, BE and CR may be essential as pre-treatment imaging examinations because they occasionally detect findings which affect treatment indication and strategy, although abdominal contrast-enhanced CT rarely provide additional information.

  4. Quantitative fundus autofluorescence in healthy eyes.

    Science.gov (United States)

    Greenberg, Jonathan P; Duncker, Tobias; Woods, Russell L; Smith, R Theodore; Sparrow, Janet R; Delori, François C

    2013-08-21

    Fundus autofluorescence was quantified (qAF) in subjects with healthy retinae using a standardized approach. The objective was to establish normative data and identify factors that influence the accumulation of RPE lipofuscin and/or modulate the observed AF signal in fundus images. AF images were acquired from 277 healthy subjects (age range: 5-60 years) by employing a Spectralis confocal scanning laser ophthalmoscope (cSLO; 488-nm excitation; 30°) equipped with an internal fluorescent reference. For each image, mean gray level was calculated as the average of eight preset regions, and was calibrated to the reference, zero-laser light, magnification, and optical media density from normative data on lens transmission spectra. Relationships between qAF and age, sex, race/ethnicity, eye color, refraction/axial length, and smoking status were evaluated as was measurement repeatability and the qAF spatial distribution. qAF levels exhibited a significant increase with age. qAF increased with increasing eccentricity up to 10° to 15° from the fovea and was highest superotemporally. qAF values were significantly greater in females, and, compared with Hispanics, qAF was significantly higher in whites and lower in blacks and Asians. No associations with axial length and smoking were observed. For two operators, between-session repeatability was ± 9% and ± 12%. Agreement between the operators was ± 13%. Normative qAF data are a reference tool essential to the interpretation of qAF measurements in ocular disease.

  5. Autofluorescence Imaging and Spectral-Domain Optical Coherence Tomography in Incomplete Congenital Stationary Night Blindness and Comparison with Retinitis Pigmentosa

    Science.gov (United States)

    CHEN, ROYCE W. S.; GREENBERG, JONATHAN P.; LAZOW, MARGOT A.; RAMACHANDRAN, RITHU; LIMA, LUIZ H.; HWANG, JOHN C.; SCHUBERT, CARL; BRAUNSTEIN, ALEXANDRA; ALLIKMETS, RANDO; TSANG, STEPHEN H.

    2015-01-01

    PURPOSE To test the hypothesis that the evaluation of retinal structure can have diagnostic value in differentiating between incomplete congenital stationary night blindness (CSNB2) and retinitis pigmentosa (RP). To compare retinal thickness differences between patients with CSNB2 and myopic controls. DESIGN Prospective cross-sectional study. METHODS Ten eyes of 5 patients diagnosed with CSNB2 (4 X-linked recessive, 1 autosomal recessive) and 6 eyes of 3 patients with RP (2 autosomal dominant, 1 autosomal recessive) were evaluated with spectral-domain optical coherence tomography (SD OCT) and fundus autofluorescence (FAF). Diagnoses of CSNB2 and RP were confirmed by full-field electroretinography (ERG). Manual segmentation of retinal layers, aided by a computer program, was performed by 2 professional segmenters on SD OCT images of all CSNB2 patients and 4 age-similar, normal myopic controls. Seven patients were screened for mutations with congenital stationary night blindness and RP genotyping arrays. RESULTS Patients with CSNB2 had specific findings on SD OCT and FAF that were distinct from those found in RP. CSNB2 patients showed qualitatively normal SD OCT results with preserved photoreceptor inner segment/outer segment junction, whereas this junction was lost in RP patients. In addition, CSNB2 patients had normal FAF images, whereas patients with RP demonstrated a ring of increased autofluorescence around the macula. On SD OCT segmentation, the inner and outer retinal layers of both X-linked recessive and autosomal recessive CSNB2 patients were thinner compared with those of normal myopic controls, with means generally outside of normal 95% confidence intervals. The only layers that demonstrated similar thickness between CSNB2 patients and the controls were the retinal nerve fiber layer and, temporal to the fovea, the combined outer segment layer and retinal pigment epithelium. A proband and his 2 affected brothers from a family segregating X-linked recessive

  6. Laser-induced fluorescence imaging of bacteria

    Science.gov (United States)

    Hilton, Peter J.

    1998-12-01

    This paper outlines a method for optically detecting bacteria on various backgrounds, such as meat, by imaging their laser induced auto-fluorescence response. This method can potentially operate in real-time, which is many times faster than current bacterial detection methods, which require culturing of bacterial samples. This paper describes the imaging technique employed whereby a laser spot is scanned across an object while capturing, filtering, and digitizing the returned light. Preliminary results of the bacterial auto-fluorescence are reported and plans for future research are discussed. The results to date are encouraging with six of the eight bacterial strains investigated exhibiting auto-fluorescence when excited at 488 nm. Discrimination of these bacterial strains against red meat is shown and techniques for reducing background fluorescence discussed.

  7. Evaluation of fundus autofluorescence in hereditary retinal diseases using Heidelberg Retina Angiograph2

    OpenAIRE

    Côco, Monique [UNIFESP; Baba, Natalia Tamie [UNIFESP; Sallum, Juliana Maria Ferraz [UNIFESP

    2007-01-01

    OBJETIVOS: Definir características do exame de autofluorescência, verificando sua utilidade no diagnóstico e acompanhamento de distrofias retinianas. MÉTODOS: Participaram do estudo, 28 pacientes, adultos, divididos igualmente em quatro grupos com diagnósticos de doença de Stargardt, distrofia de Cones, retinose pigmentar e voluntários saudáveis para estabelecimento do padrão de normalidade. Em média foram obtidas nove imagens com o filtro para angiofluoresceinografia para a formação da image...

  8. Low-complexity video encoding method for wireless image transmission in capsule endoscope.

    Science.gov (United States)

    Takizawa, Kenichi; Hamaguchi, Kiyoshi

    2010-01-01

    This paper presents a low-complexity video encoding method applicable for wireless image transmission in capsule endoscopes. This encoding method is based on Wyner-Ziv theory, in which side information available at a transmitter is treated as side information at its receiver. Therefore complex processes in video encoding, such as estimation of the motion vector, are moved to the receiver side, which has a larger-capacity battery. As a result, the encoding process is only to decimate coded original data through channel coding. We provide a performance evaluation for a low-density parity check (LDPC) coding method in the AWGN channel.

  9. Quantitative analysis of myocardial tissue with digital autofluorescence microscopy

    DEFF Research Database (Denmark)

    Jensen, Thomas; Holten-Rossing, Henrik; Svendsen, Ida M H

    2016-01-01

    to that of hematoxylin and eosin staining in conventional pathology. This study presents an automated fluorescence-based microscopy approach providing highly detailed morphological data from unstained microsections. This data may provide a basic histological starting point from which further digital analysis including...... staining may benefit. METHODS: This study explores the inherent tissue fluorescence, also known as autofluorescence, as a mean to quantitate cardiac tissue components in histological microsections. Data acquisition using a commercially available whole slide scanner and an image-based quantitation algorithm......BACKGROUND: The opportunity offered by whole slide scanners of automated histological analysis implies an ever increasing importance of digital pathology. To go beyond the importance of conventional pathology, however, digital pathology may need a basic histological starting point similar...

  10. In vivo endoscopic multi-beam optical coherence tomography

    Energy Technology Data Exchange (ETDEWEB)

    Standish, Beau A; Mariampillai, Adrian; Munce, Nigel R; Leung, Michael K K; Vitkin, I Alex [Deptartment of Medical Biophysics, University of Toronto, Toronto (Canada); Lee, Kenneth K C; Yang, Victor X D [Ontario Cancer Institute/University Health Network, Toronto (Canada)], E-mail: standish@ee.ryerson.ca

    2010-02-07

    A multichannel optical coherence tomography (multi-beam OCT) system and an in vivo endoscopic imaging probe were developed using a swept-source OCT system. The distal optics were micro-machined to produce a high numerical aperture, multi-focus fibre optic array. This combination resulted in a transverse design resolution of <10 {mu}m full width half maximum (FWHM) throughout the entire imaging range, while also increasing the signal intensity within the focus of the individual channels. The system was used in a pre-clinical rabbit study to acquire in vivo structural images of the colon and ex vivo images of the oesophagus and trachea. A good correlation between the structural multi-beam OCT images and H and E histology was achieved, demonstrating the feasibility of this high-resolution system and its potential for in vivo human endoscopic imaging.

  11. In vivo endoscopic multi-beam optical coherence tomography

    International Nuclear Information System (INIS)

    Standish, Beau A; Mariampillai, Adrian; Munce, Nigel R; Leung, Michael K K; Vitkin, I Alex; Lee, Kenneth K C; Yang, Victor X D

    2010-01-01

    A multichannel optical coherence tomography (multi-beam OCT) system and an in vivo endoscopic imaging probe were developed using a swept-source OCT system. The distal optics were micro-machined to produce a high numerical aperture, multi-focus fibre optic array. This combination resulted in a transverse design resolution of <10 μm full width half maximum (FWHM) throughout the entire imaging range, while also increasing the signal intensity within the focus of the individual channels. The system was used in a pre-clinical rabbit study to acquire in vivo structural images of the colon and ex vivo images of the oesophagus and trachea. A good correlation between the structural multi-beam OCT images and H and E histology was achieved, demonstrating the feasibility of this high-resolution system and its potential for in vivo human endoscopic imaging.

  12. Quantitative Fundus Autofluorescence in Recessive Stargardt Disease

    OpenAIRE

    Burke, Tomas R.; Duncker, Tobias; Woods, Russell L.; Greenberg, Jonathan P.; Zernant, Jana; Tsang, Stephen H.; Smith, R. Theodore; Allikmets, Rando; Sparrow, Janet R.; Delori, François C.

    2014-01-01

    Quantitative fundus autofluorescence (qAF) is significantly increased in Stargardt disease, consistent with previous reports of increased RPE lipofuscin. QAF will help to establish genotype-phenotype correlations and may serve as an outcome measure in clinical trials.

  13. Ultrasound-assisted endoscopic partial plantar fascia release.

    Science.gov (United States)

    Ohuchi, Hiroshi; Ichikawa, Ken; Shinga, Kotaro; Hattori, Soichi; Yamada, Shin; Takahashi, Kazuhisa

    2013-01-01

    Various surgical treatment procedures for plantar fasciitis, such as open surgery, percutaneous release, and endoscopic surgery, exist. Skin trouble, nerve disturbance, infection, and persistent pain associated with prolonged recovery time are complications of open surgery. Endoscopic partial plantar fascia release offers the surgeon clear visualization of the anatomy at the surgical site. However, the primary medial portal and portal tract used for this technique have been shown to be in close proximity to the posterior tibial nerves and their branches, and there is always the risk of nerve damage by introducing the endoscope deep to the plantar fascia. By performing endoscopic partial plantar fascia release under ultrasound assistance, we could dynamically visualize the direction of the endoscope and instrument introduction, thus preventing nerve damage from inadvertent insertion deep to the fascia. Full-thickness release of the plantar fascia at the ideal position could also be confirmed under ultrasound imaging. We discuss the technique for this new procedure.

  14. Feasibility study of novel endoscopic Cerenkov luminescence imaging system in detecting and quantifying gastrointestinal disease: first human results

    International Nuclear Information System (INIS)

    Hu, Hao; Li, Shujun; Yao, Liping; Liang, Jie; Nie, Yongzhan; Wu, Kaichun; Cao, Xin; Lin, Yenan; Liu, Muhan; Liang, Jimin; Chen, Xueli; Kang, Fei; Wang, Jing; Wang, Min

    2015-01-01

    Cerenkov luminescence imaging (CLI) provides potential to use clinical radiotracers for optical imaging. The goal of this study was to present a newly developed endoscopic CLI (ECLI) system and illustrate its feasibility and potential in distinguishing and quantifying cancerous lesions of the GI tract. The ECLI system was established by integrating an electron-multiplying charge-coupled device camera with a flexible fibre endoscope. Phantom experiments and animal studies were conducted to test and illustrate the system in detecting and quantifying the presence of radionuclide in vitro and in vivo. A pilot clinical study was performed to evaluate our system in clinical settings. Phantom and mice experiments demonstrated its ability to acquire both the luminescent and photographic images with high accuracy. Linear quantitative relationships were also obtained when comparing the ECLI radiance with the radiotracer activity (r 2 = 0.9779) and traditional CLI values (r 2 = 0.9025). Imaging of patients revealed the potential of ECLI in the identification and quantification of cancerous tissue from normal, which showed good consistence with the clinical PET examination. The new ECLI system shows good consistence with the clinical PET examination and has great potential for clinical translation and in aiding detection of the GI tract disease. (orig.)

  15. Feasibility study of novel endoscopic Cerenkov luminescence imaging system in detecting and quantifying gastrointestinal disease: first human results

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Hao; Li, Shujun; Yao, Liping; Liang, Jie; Nie, Yongzhan; Wu, Kaichun [Fourth Military Medical University, State Key Laboratory of Cancer Biology, Department of Digestive Diseases, Xijing Hospital, Xi' an (China); Cao, Xin; Lin, Yenan; Liu, Muhan; Liang, Jimin; Chen, Xueli [Xidian University, School of Life Science and Technology, Xi' an (China); Kang, Fei; Wang, Jing [Fourth Military Medical University, Department of Nuclear Medicine, Xijing Hospital, Xi' an (China); Wang, Min [Xi' an Children' s Hospital, Department of Gastroenterology, Xi' an (China)

    2015-06-01

    Cerenkov luminescence imaging (CLI) provides potential to use clinical radiotracers for optical imaging. The goal of this study was to present a newly developed endoscopic CLI (ECLI) system and illustrate its feasibility and potential in distinguishing and quantifying cancerous lesions of the GI tract. The ECLI system was established by integrating an electron-multiplying charge-coupled device camera with a flexible fibre endoscope. Phantom experiments and animal studies were conducted to test and illustrate the system in detecting and quantifying the presence of radionuclide in vitro and in vivo. A pilot clinical study was performed to evaluate our system in clinical settings. Phantom and mice experiments demonstrated its ability to acquire both the luminescent and photographic images with high accuracy. Linear quantitative relationships were also obtained when comparing the ECLI radiance with the radiotracer activity (r{sup 2} = 0.9779) and traditional CLI values (r{sup 2} = 0.9025). Imaging of patients revealed the potential of ECLI in the identification and quantification of cancerous tissue from normal, which showed good consistence with the clinical PET examination. The new ECLI system shows good consistence with the clinical PET examination and has great potential for clinical translation and in aiding detection of the GI tract disease. (orig.)

  16. Suppression of Red Blood Cell Autofluorescence for Immunocytochemistry on Fixed Embryonic Mouse Tissue.

    Science.gov (United States)

    Whittington, Niteace C; Wray, Susan

    2017-10-23

    Autofluorescence is a problem that interferes with immunofluorescent staining and complicates data analysis. Throughout the mouse embryo, red blood cells naturally fluoresce across multiple wavelengths, spanning the emission and excitation spectra of many commonly used fluorescent reporters, including antibodies, dyes, stains, probes, and transgenic proteins, making it difficult to distinguish assay fluorescence from endogenous fluorescence. Several tissue treatment methods have been developed to bypass this issue with varying degrees of success. Sudan Black B dye has been commonly used to quench autofluorescence, but can also introduce background fluorescence. Here we present a protocol for an alternative called TrueBlack Lipofuscin Autofluorescence Quencher. The protocol described in this unit demonstrates how TrueBlack efficiently quenches red blood cell autofluorescence across red and green wavelengths in fixed embryonic tissue without interfering with immunofluorescent signal intensity or introducing background staining. We also identify optimal incubation, concentration, and multiple usage conditions for routine immunofluorescence microscopy. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  17. Combination of panoramic and fluorescence endoscopic images to obtain tumor spatial distribution information useful for bladder cancer detection

    Science.gov (United States)

    Olijnyk, S.; Hernández Mier, Y.; Blondel, W. C. P. M.; Daul, C.; Wolf, D.; Bourg-Heckly, G.

    2007-07-01

    Bladder cancer is widely spread. Moreover, carcinoma in situ can be difficult to diagnose as it may be difficult to see, and become invasive in 50 % of case. Non invasive diagnosis methods like photodynamic or autofluorescence endoscopy allow enhancing sensitivity and specificity. Besides, bladder tumors can be multifocal. Multifocality increases the probability of recurrence and infiltration into bladder muscle. Analysis of spatial distribution of tumors could be used to improve diagnosis. We explore the feasibility to combine fluorescence and spatial information on phantoms. We developed a system allowing the acquisition of consecutive images under white light or UV excitation alternatively and automatically along the video sequence. We also developed an automatic image processing algorithm to build a partial panoramic image from a cystoscopic sequence of images. Fluorescence information is extracted from wavelength bandpass filtered images and superimposed over the cartography. Then, spatial distribution measures of fluorescent spots can be computed. This cartography can be positioned on a 3D generic shape of bladder by selecting some reference points. Our first results on phantoms show that it is possible to obtain cartography with fluorescent spots and extract quantitative information of their spatial distribution on a "wide" field of view basis.

  18. Skin autofluorescence is associated with the progression of chronic kidney disease: a prospective observational study.

    Science.gov (United States)

    Tanaka, Kenichi; Nakayama, Masaaki; Kanno, Makoto; Kimura, Hiroshi; Watanabe, Kimio; Tani, Yoshihiro; Kusano, Yuki; Suzuki, Hodaka; Hayashi, Yoshimitsu; Asahi, Koichi; Sato, Keiji; Miyata, Toshio; Watanabe, Tsuyoshi

    2013-01-01

    Advanced glycation end product (AGE) accumulation is thought to be a measure of cumulative metabolic stress that has been reported to independently predict cardiovascular disease in diabetes and renal failure. The aim of this study was to evaluate the association between AGE accumulation, measured as skin autofluorescence, and the progression of renal disease in pre-dialysis patients with chronic kidney disease (CKD). Skin autofluorescence was measured noninvasively with an autofluorescence reader at baseline in 449 pre-dialysis patients with CKD. The primary end point was defined as a doubling of serum creatinine and/or need for dialysis. Thirty-three patients were lost to follow-up. Forty six patients reached the primary end point during the follow-up period (Median 39 months). Kaplan-Meier analysis showed a significantly higher risk of development of the primary end points in patients with skin autofluorescence levels above the optimal cut-off level of 2.31 arbitrary units, derived by receiver operator curve analysis. Cox regression analysis revealed that skin autofluorescence was an independent predictor of the primary end point, even after adjustment for age, gender, smoking history, diabetes, estimated glomerular filtration rate and proteinuria (adjusted hazard ratio 2.58, P = 0.004). Tissue accumulation of AGEs, measured as skin autofluorescence, is a strong and independent predictor of progression of CKD. Skin autofluorescence may be useful for risk stratification in this group of patients; further studies should clarify whether AGE accumulation could be one of the therapeutic targets to improve the prognosis of CKD.

  19. Dermal factors influencing measurement of skin autofluorescence

    NARCIS (Netherlands)

    Noordzij, Margaretha J.; Lefrandt, Johan; Graaff, Reindert; Smit, Andries J.

    Background: Skin autofluorescence (SAF) is a noninvasive marker of accumulation of advanced glycation end products. It predicts cardiovascular complications and mortality in diabetes and renal failure. We assessed the influence of potential common confounders in SAF measurement, by determining the

  20. Long-term reduction in infrared autofluorescence caused by infrared light below the maximum permissible exposure.

    Science.gov (United States)

    Masella, Benjamin D; Williams, David R; Fischer, William S; Rossi, Ethan A; Hunter, Jennifer J

    2014-05-20

    Many retinal imaging instruments use infrared wavelengths to reduce the risk of light damage. However, we have discovered that exposure to infrared illumination causes a long-lasting reduction in infrared autofluorescence (IRAF). We have characterized the dependence of this effect on radiant exposure and investigated its origin. A scanning laser ophthalmoscope was used to obtain IRAF images from two macaques before and after exposure to 790-nm light (15-450 J/cm(2)). Exposures were performed with either raster-scanning or uniform illumination. Infrared autofluorescence images also were obtained in two humans exposed to 790-nm light in a separate study. Humans were assessed with direct ophthalmoscopy, Goldmann visual fields, multifocal ERG, and photopic microperimetry to determine whether these measures revealed any effects in the exposed locations. A significant decrease in IRAF after exposure to infrared light was seen in both monkeys and humans. In monkeys, the magnitude of this reduction increased with retinal radiant exposure. Partial recovery was seen at 1 month, with full recovery within 21 months. Consistent with a photochemical origin, IRAF decreases caused by either raster-scanning or uniform illumination were not significantly different. We were unable to detect any effect of the light exposure with any measure other than IRAF imaging. We cannot exclude the possibility that changes could be detected with more sensitive tests or longer follow-up. This long-lasting effect of infrared illumination in both humans and monkeys occurs at exposure levels four to five times below current safety limits. The photochemical basis for this phenomenon remains unknown. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  1. Adaptive optics fundus images of cone photoreceptors in the macula of patients with retinitis pigmentosa.

    Science.gov (United States)

    Tojo, Naoki; Nakamura, Tomoko; Fuchizawa, Chiharu; Oiwake, Toshihiko; Hayashi, Atsushi

    2013-01-01

    The purpose of this study was to examine cone photoreceptors in the macula of patients with retinitis pigmentosa using an adaptive optics fundus camera and to investigate any correlations between cone photoreceptor density and findings on optical coherence tomography and fundus autofluorescence. We examined two patients with typical retinitis pigmentosa who underwent ophthalmological examination, including measurement of visual acuity, and gathering of electroretinographic, optical coherence tomographic, fundus autofluorescent, and adaptive optics fundus images. The cone photoreceptors in the adaptive optics images of the two patients with retinitis pigmentosa and five healthy subjects were analyzed. An abnormal parafoveal ring of high-density fundus autofluorescence was observed in the macula in both patients. The border of the ring corresponded to the border of the external limiting membrane and the inner segment and outer segment line in the optical coherence tomographic images. Cone photoreceptors at the abnormal parafoveal ring were blurred and decreased in the adaptive optics images. The blurred area corresponded to the abnormal parafoveal ring in the fundus autofluorescence images. Cone densities were low at the blurred areas and at the nasal and temporal retina along a line from the fovea compared with those of healthy controls. The results for cone spacing and Voronoi domains in the macula corresponded with those for the cone densities. Cone densities were heavily decreased in the macula, especially at the parafoveal ring on high-density fundus autofluorescence in both patients with retinitis pigmentosa. Adaptive optics images enabled us to observe in vivo changes in the cone photoreceptors of patients with retinitis pigmentosa, which corresponded to changes in the optical coherence tomographic and fundus autofluorescence images.

  2. Development of image-guided operation system having integrated information of the patient for procedure of endoscopic surgery of digestive tracts

    International Nuclear Information System (INIS)

    Hattori, Asaki; Suzuki, Naoki; Tanoue, Kazuo; Ieiri, Satoshi; Konishi, Kozo; Tomikawa, Morimasa; Kenmotsu, Hajime; Hashizume, Makoto

    2010-01-01

    This study reports the development of patient's integrated information-displaying system at image-guided, robotic peroral endoscopic operation of digestive tracts as well as the actual operative field for the operator not to look aside. The peroral endoscope has, at its top, a magnetic position sensor and 2 robotic manipulative forceps at right and left side to navigate the surgery through following 3 windows of superimposing display: the inner peritoneal 3D structure of the real operative field reconstructed from preoperative CT and MR images by volume rendering, presentation of the robot top tip in the structure above and in the preoperative CT or MR image as an ordinary navigation. Furthermore, the robot has a function to measure softness of its grabbing tissue which is displayed in the corresponding right and left superimposing windows, and signs like the real-time blood pressure and heart rate are also given in another window. All of the patient's integrated information-displaying can be handled at will during the operation. Improvement of user interface and of navigation display is further to be conducted. (T.T.)

  3. An algorithm for improving the quality of structural images of turbid media in endoscopic optical coherence tomography

    Science.gov (United States)

    Potlov, A. Yu.; Frolov, S. V.; Proskurin, S. G.

    2018-04-01

    High-quality OCT structural images reconstruction algorithm for endoscopic optical coherence tomography of biological tissue is described. The key features of the presented algorithm are: (1) raster scanning and averaging of adjacent Ascans and pixels; (2) speckle level minimization. The described algorithm can be used in the gastroenterology, urology, gynecology, otorhinolaryngology for mucous membranes and skin diagnostics in vivo and in situ.

  4. Adaptive optics fundus images of cone photoreceptors in the macula of patients with retinitis pigmentosa

    Directory of Open Access Journals (Sweden)

    Tojo N

    2013-01-01

    Full Text Available Naoki Tojo, Tomoko Nakamura, Chiharu Fuchizawa, Toshihiko Oiwake, Atsushi HayashiDepartment of Ophthalmology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Toyama, JapanBackground: The purpose of this study was to examine cone photoreceptors in the macula of patients with retinitis pigmentosa using an adaptive optics fundus camera and to investigate any correlations between cone photoreceptor density and findings on optical coherence tomography and fundus autofluorescence.Methods: We examined two patients with typical retinitis pigmentosa who underwent ophthalmological examination, including measurement of visual acuity, and gathering of electroretinographic, optical coherence tomographic, fundus autofluorescent, and adaptive optics fundus images. The cone photoreceptors in the adaptive optics images of the two patients with retinitis pigmentosa and five healthy subjects were analyzed.Results: An abnormal parafoveal ring of high-density fundus autofluorescence was observed in the macula in both patients. The border of the ring corresponded to the border of the external limiting membrane and the inner segment and outer segment line in the optical coherence tomographic images. Cone photoreceptors at the abnormal parafoveal ring were blurred and decreased in the adaptive optics images. The blurred area corresponded to the abnormal parafoveal ring in the fundus autofluorescence images. Cone densities were low at the blurred areas and at the nasal and temporal retina along a line from the fovea compared with those of healthy controls. The results for cone spacing and Voronoi domains in the macula corresponded with those for the cone densities.Conclusion: Cone densities were heavily decreased in the macula, especially at the parafoveal ring on high-density fundus autofluorescence in both patients with retinitis pigmentosa. Adaptive optics images enabled us to observe in vivo changes in the cone photoreceptors of

  5. Diabetic retinal pigment epitheliopathy: fundus autofluorescence and spectral-domain optical coherence tomography findings.

    Science.gov (United States)

    Kang, Eui Chun; Seo, Yuri; Byeon, Suk Ho

    2016-10-01

    To describe the characteristics of an unfamiliar disease entity, diabetic retinal pigment epitheliopathy (DRPE), using fundus autofluorescence (FAF) and spectral-domain optical coherence tomography (SD-OCT). This retrospective study included 17 eyes from 10 proliferative diabetic retinopathy (PDR) patients with granular hypo-autofluorescence and/or variable hyper-autofluorescence on FAF (DRPE group) and 17 eyes from 10 age- and sex-matched PDR patients without abnormal autofluorescence (PDR group). Eyes with diabetic macular edema were excluded. Visual acuity (VA), retinal thickness (RT), and choroidal thickness (CT) were compared between the groups. Eyes in the DRPE group had worse logMAR VA than eyes in the PDR group (0.369 ± 0.266 vs. 0.185 ± 0.119; P = 0.026). The thickness of the retinal pigment epithelium plus the inner segment/outer segment of the photoreceptors was reduced to a greater degree in the DRPE group than the PDR group (P retina showed no differences between the two groups. CT was significantly thicker in the DRPE group than in the PDR group (329.00 ± 33.76 vs. 225.62 ± 37.47 μm; P retina, and thicker choroid in comparison with eyes with PDR. Alterations of autofluorescence on FAF and changes in the outer retinal thickness and CT on SD-OCT can be helpful for differentiating DRPE in patients with PDR.

  6. Progressive Retinal Degeneration and Accumulation of Autofluorescent Lipopigments in Progranulin Deficient Mice

    Science.gov (United States)

    Hafler, Brian P.; Klein, Zoe A.; Zhou, Z. Jimmy; Strittmatter, Stephen M.

    2014-01-01

    Prior investigations have shown that patients with neuronal ceroid lipofuscinosis (NCL) develop neurodegeneration characterized by vision loss, motor dysfunction, seizures, and often early death. Neuropathological analysis of patients with NCL shows accumulation of intracellular autofluorescent storage material, lipopigment, throughout neurons in the central nervous system including in the retina. A recent study of a sibling pair with adult onset NCL and retinal degeneration showed linkage to the region of the progranulin (GRN) locus and a homozygous mutation was demonstrated in GRN. In particular, the sibling pair with a mutation in GRN developed retinal degeneration and optic atrophy. This locus for this form of adult onset neuronal ceroid lipofuscinosis was designated neuronal ceroid lipofuscinosis-11 (CLN11). Based on these clinical observations, we wished to determine whether Grn-null mice develop accumulation of autofluorescent particles and retinal degeneration. Retinas of both wild-type and Progranulin deficient mice were examined by immunostaining and autofluorescence. Accumulation of autofluorescent material was present in Progranulin deficient mice at 12 months. Degeneration of multiple classes of neurons including photoreceptors and retinal ganglion cells was noted in mice at 12 and 18 months. Our data shows that Grn−/− mice develop degenerative pathology similar to features of human CLN11. PMID:25234724

  7. Fundus autofluorescence and optical coherence tomography in the management of progressive outer retinal necrosis

    Science.gov (United States)

    Yeh, Steven; Wong, Wai T.; Weichel, Eric D.; Lew, Julie C.; Chew, Emily Y.; Nussenblatt, Robert B.

    2011-01-01

    A 41 year-old female patient with acquired immune deficiency syndrome (AIDS) presented with progressive nasal visual field loss in her right eye. Ophthalmic exam revealed widespread areas of retinal opacification with hemorrhage consistent with progressive outer retinal necrosis (PORN), which was confirmed by polymerase chain reaction (PCR) for varicella zoster virus (VZV) DNA. The patient was treated with intravenous and intravitreal foscarnet and ganciclovir with a resultant improvement clinically. Optical coherence tomography (OCT) and fundus autofluorescence (FAF) imaging revealed progressive changes indicative of widespread retinal pigment epithelial (RPE) and outer retinal dysfunction. OCT was useful in documenting progressive changes in macular architecture during therapy including neurosensory elevation, cystoid macular edema, and severe outer retinal necrosis, at initial exam, 1 week, and 1 month follow-up. Fundus autofluorescence revealed areas of stippled, hyperfluorescence within extensive zones of hypofluorescence, which progressed during the follow-up period. These areas appeared to represent lipofuscin or its photoreactive components within larger regions of RPE loss. The combination of OCT and FAF was useful in the characterization of the RPE and retinal anatomy in this patient with PORN. PMID:20337261

  8. Endoscopic mode for three-dimensional CT display of normal and pathologic laryngeal structures

    International Nuclear Information System (INIS)

    Sanuki, Tetsuji; Hyodo, Masamitsu; Yumoto, Eiji; Yasuhara, Yoshifumi; Ochi, Takashi

    1997-01-01

    The recent development of helical (spiral) computed tomography allows collection of volumetric data to obtain high quality three-dimensional (3D) reconstructed images. The authors applied the 3D CT endoscopic imaging technique to asses normal and pathologic laryngeal structures. The latter included trauma, vocal fold atrophy, cancer of the larynx and recurrent nerve palsy. This technique was able to show normal laryngeal structures and characteristic findings of each pathology. The 3D CT endoscopic images can be rotated around any axis, allowing optimal depiction of pathologic lesion. The use of 3D CT endoscopic technique provides the display of the location and extent of pathology and affords accurate therapeutic planning. (author)

  9. Detection of Parathyroid Autofluorescence Using Near-Infrared Imaging: A Multicenter Analysis of Concordance Between Different Surgeons.

    Science.gov (United States)

    Kahramangil, Bora; Dip, Fernando; Benmiloud, Fares; Falco, Jorge; de La Fuente, Martin; Verna, Silvina; Rosenthal, Raul; Berber, Eren

    2018-04-01

    Parathyroid glands (PGs) exhibit autofluorescence (AF) when excited by near-infrared laser. This multicenter study aims to analyze how this imaging could facilitate the detection of PGs during thyroidectomy and parathyroidectomy procedures. This was a retrospective Institutional Review Board-approved analysis of prospectively collected data at three centers. Near-infrared fluorescence imaging (NIFI) was used to detect AF from PGs during thyroidectomy and parathyroidectomy procedures. Logistic regression analysis was performed to assess the utility of NIFI to identify PGs and concordance at these centers. Overall, 210 patients underwent total thyroidectomy (n = 95), thyroid lobectomy (n = 41), and parathyroidectomy (n = 74) (n = 70 per center). Using NIFI, AF was detected from 98% of visually identified PGs. Upon initial exploration, 46% of PGs were not visible to the naked eye due to coverage by soft tissue, but AF from these glands could be detected by NIFI without any further dissection. Overall, a median of one PG per patient was detected by NIFI in this fashion before being identified visually (p = nonsignificant between centers). On logistic regression, smaller PGs were more likely to be missed visually, but localized by AF on NIFI (odds ratio with increasing size, 0.91; p = 0.02). In our experience, NIFI facilitated PG identification by detecting their AF, before conventional recognition by the surgeon, in 37-67% of the time. Despite the variability in this rate across centers, there was a concordance in detecting AF from 97 to 99% of the PGs using NIFI. We suggest the incorporation of AF on NIFI alongside conventional visual cues to aid identification of PGs during neck operations.

  10. Combining endoscopes with PIV and digital holography for the study of vessel model mechanics

    International Nuclear Information System (INIS)

    Arévalo, Laura; Palero, Virginia; Andrés, Nieves; Arroyo, M P; Lobera, Julia

    2015-01-01

    In this work traditional fluid and solid mechanics measurement techniques have been combined with endoscopes for the study of blood vessel models’ mechanical properties. Endoscopes have been used as the imaging part of a high-speed PIV system to obtain the velocity field in a vessel model immersed in a container with a refractive index-matching liquid. In this way, we take advantage of the fact that the endoscope tip can be immersed in liquid. Endoscopes have also been used as the imaging and illuminating part of a digital holographic set-up for wall deformation measurement. The novelty of this work is that only one endoscope was used for illuminating and observing the vessel model, using the endoscope’s own illuminating system as the illumination source. The performance of endoscopes in different vessel models has been tested. The results of flow velocity and wall deformation in the different blood vessel models are presented. (paper)

  11. A hybrid segmentation approach for geographic atrophy in fundus auto-fluorescence images for diagnosis of age-related macular degeneration.

    Science.gov (United States)

    Lee, Noah; Laine, Andrew F; Smith, R Theodore

    2007-01-01

    Fundus auto-fluorescence (FAF) images with hypo-fluorescence indicate geographic atrophy (GA) of the retinal pigment epithelium (RPE) in age-related macular degeneration (AMD). Manual quantification of GA is time consuming and prone to inter- and intra-observer variability. Automatic quantification is important for determining disease progression and facilitating clinical diagnosis of AMD. In this paper we describe a hybrid segmentation method for GA quantification by identifying hypo-fluorescent GA regions from other interfering retinal vessel structures. First, we employ background illumination correction exploiting a non-linear adaptive smoothing operator. Then, we use the level set framework to perform segmentation of hypo-fluorescent areas. Finally, we present an energy function combining morphological scale-space analysis with a geometric model-based approach to perform segmentation refinement of false positive hypo- fluorescent areas due to interfering retinal structures. The clinically apparent areas of hypo-fluorescence were drawn by an expert grader and compared on a pixel by pixel basis to our segmentation results. The mean sensitivity and specificity of the ROC analysis were 0.89 and 0.98%.

  12. Full optical model of micro-endoscope with optical coherence microscopy, multiphoton microscopy and visible capabilities

    Science.gov (United States)

    Vega, David; Kiekens, Kelli C.; Syson, Nikolas C.; Romano, Gabriella; Baker, Tressa; Barton, Jennifer K.

    2018-02-01

    While Optical Coherence Microscopy (OCM), Multiphoton Microscopy (MPM), and narrowband imaging are powerful imaging techniques that can be used to detect cancer, each imaging technique has limitations when used by itself. Combining them into an endoscope to work in synergy can help achieve high sensitivity and specificity for diagnosis at the point of care. Such complex endoscopes have an elevated risk of failure, and performing proper modelling ensures functionality and minimizes risk. We present full 2D and 3D models of a multimodality optical micro-endoscope to provide real-time detection of carcinomas, called a salpingoscope. The models evaluate the endoscope illumination and light collection capabilities of various modalities. The design features two optical paths with different numerical apertures (NA) through a single lens system with a scanning optical fiber. The dual path is achieved using dichroic coatings embedded in a triplet. A high NA optical path is designed to perform OCM and MPM while a low NA optical path is designed for the visible spectrum to navigate the endoscope to areas of interest and narrowband imaging. Different tests such as the reflectance profile of homogeneous epithelial tissue were performed to adjust the models properly. Light collection models for the different modalities were created and tested for efficiency. While it is challenging to evaluate the efficiency of multimodality endoscopes, the models ensure that the system is design for the expected light collection levels to provide detectable signal to work for the intended imaging.

  13. High-quality endoscope reprocessing decreases endoscope contamination.

    Science.gov (United States)

    Decristoforo, P; Kaltseis, J; Fritz, A; Edlinger, M; Posch, W; Wilflingseder, D; Lass-Flörl, C; Orth-Höller, D

    2018-02-24

    Several outbreaks of severe infections due to contamination of gastrointestinal (GI) endoscopes, mainly duodenoscopes, have been described. The rate of microbial endoscope contamination varies dramatically in literature. The aim of this multicentre prospective study was to evaluate the hygiene quality of endoscopes and automated endoscope reprocessors (AERs) in Tyrol/Austria. In 2015 and 2016, a total of 463 GI endoscopes and 105 AERs from 29 endoscopy centres were analysed by a routine (R) and a combined routine and advanced (CRA) sampling procedure and investigated for microbial contamination by culture-based and molecular-based analyses. The contamination rate of GI endoscopes was 1.3%-4.6% according to the national guideline, suggesting that 1.3-4.6 patients out of 100 could have had contacts with hygiene-relevant microorganisms through an endoscopic intervention. Comparison of R and CRA sampling showed 1.8% of R versus 4.6% of CRA failing the acceptance criteria in phase I and 1.3% of R versus 3.0% of CRA samples failing in phase II. The most commonly identified indicator organism was Pseudomonas spp., mainly Pseudomonas oleovorans. None of the tested viruses were detected in 40 samples. While AERs in phase I failed (n = 9, 17.6%) mainly due to technical faults, phase II revealed lapses (n = 6, 11.5%) only on account of microbial contamination of the last rinsing water, mainly with Pseudomonas spp. In the present study the contamination rate of endoscopes was low compared with results from other European countries, possibly due to the high quality of endoscope reprocessing, drying and storage. Copyright © 2018 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  14. Benign submucosal lesions of the stomach and duodenum: Imaging characteristics with endoscopic and pathologic correlation

    International Nuclear Information System (INIS)

    Oh, Jong Young; Nam, Kyung Jin; Choi, Jong Cheol; Cho, Jin Han; Yoon, Seong Kuk; Choi, Sun Seob; Kwon, Hee Jin; Yoon, Jung Hee; Kim, Su Jin

    2008-01-01

    Benign submucosal lesions of the stomach and duodenum are occasionally encountered during endoscopy. But endoscopy has its limitations in the diagnosis and differentiation of these lesions, because submucosal lesions are often difficult to visualize at endoscopy due to minimal change of the overlying mucosa. Furthermore, endoscopic biopsy may not always yield adequate tissue for diagnosis due to the submucosal location of the lesions. For this reason, the role of radiologic imaging is important in the diagnosis of submucosal lesions of the stomach and duodenum. Recent advances in computed tomography (CT) and sonographic technology are helpful in narrowing the differential diagnosis of gastroduodenal submucosal lesions. In contrast to endoscopy and barium studies, CT or ultrasonography (US) provides information about both the gastric wall and the extragastric extent of the disease. Arterial phase contrast enhanced CT enables us to discriminate a mass of submucosal from that of a mucosal origin in the differential diagnosis of gastric or duodenal lesions. Although endoscopic sonography has been considered the better modality in the diagnosis of gastroduodenal submucosal lesions, transabdominal sonography can still be an alternative method to endoscopic sonography in assessing of the origin and character of the submucosal lesions. Some gastroduodenal submucosal lesions have similar radiologic findings that make differentiation difficult. But despite overlaps in radiologic findings, some lesions have characteristic radiologic features that may suggest a specific diagnosis. Knowledge of the differential diagnosis of benign submucosal lesions in the stomach and duodenum may promote correct diagnosis and appropriate treatment

  15. Endoscopic retrograde cholangiopancreatography and endoscopic ...

    African Journals Online (AJOL)

    An approach to suspected gallstone pancreatitis'based on endoscopic retrograde cholangiopancreatography (ERCP) and endoscopic sphincterotomy (ES) was adopted in 1976 and was followed in 29 patients. ERCp became the routine method of early biliary tract assessment when gallstone pancreatitis was suspected on ...

  16. Association between fundus autofluorescence and visual outcome in surgically closed macular holes.

    Science.gov (United States)

    Lee, Young Seob; Yu, Seung-Young; Cho, Nam Suk; Kim, Moo Sang; Kim, Young Gyun; Kim, Eung Suk; Kwak, Hyung Woo

    2013-06-01

    To investigate the association between fundus autofluorescence (FAF) and visual acuity, recovery of foveal microstructure, and FAF in surgically closed macular holes. Twenty-six eyes with surgically closed macular hole were classified into two groups based on foveal FAF: normal autofluorescence (NAF) or increased autofluorescence (IAF). The association between foveal FAF and visual acuity was analyzed. In addition, we examined the relationship between recovery of the foveal microstructure assessed by spectral domain optical coherence tomography and FAF after macular hole surgery. At 1 month and 6 months after surgery, there were 9 NAF eyes and 17 IAF eyes. There were no differences between NAF and IAF eyes at 1 month and 6 months after surgery. Preoperative best-corrected visual acuity (logarithm of the minimum angle of resolution) did not differ between groups. Best-corrected visual acuity was significantly higher in the NAF group than in the IAF group at 1 month postoperatively (0.59 ± 0.34 vs. 0.91 ± 0.36, P = 0.044) and tended to be higher at 6 months (0.37 ± 0.38 vs. 0.69 ± 0.53, P = 0.126). Restoration of photoreceptor external limiting membrane differed significantly in 8 NAF eyes (89%) and 4 IAF eyes (24%) at postoperation 1 month (P = 0.001). After 6 months, external limiting membrane was restored in all 9 NAF eyes (100%) and in only 11 IAF eyes (65%) (P = 0.042). Fundus autofluorescence findings observed in surgically closed macular holes correlated with visual improvement and photoreceptor status. Eyes with visual improvement had restoration of normal foveal autofluorescence and retinal microstructure, whereas eyes with persistent foveal hyperautofluorescence did not achieve complete restoration of the retinal microstructure, and visual improvement was not as significant.

  17. Endoscopic and keyhole endoscope-assisted neurosurgical approaches: a qualitative survey on technical challenges and technological solutions.

    Science.gov (United States)

    Marcus, Hani J; Cundy, Thomas P; Hughes-Hallett, Archie; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar

    2014-10-01

    The literature reflects a resurgence of interest in endoscopic and keyhole endoscope-assisted neurosurgical approaches as alternatives to conventional microsurgical approaches in carefully selected cases. The aim of this study was to assess the technical challenges of neuroendoscopy, and the scope for technological innovations to overcome these barriers. All full members of the Society of British Neurosurgeons (SBNS) were electronically invited to participate in an online survey. The open-ended structured survey asked three questions; firstly, whether the surgeon presently utilises or has experience with endoscopic or endoscope-assisted approaches; secondly, what they consider to be the major technical barriers to adopting such approaches; and thirdly, what technological advances they foresee improving safety and efficacy in the field. Responses were subjected to a qualitative research method of multi-rater emergent theme analysis. Three clear themes emerged: 1) surgical approach and better integration with image-guidance systems (20%), 2) intra-operative visualisation and improvements in neuroendoscopy (49%), and 3) surgical manipulation and improvements in instruments (74%). The analysis of responses to our open-ended survey revealed that although opinion was varied three major themes could be identified. Emerging technological advances such as augmented reality, high-definition stereo-endoscopy, and robotic joint-wristed instruments may help overcome the technical difficulties associated with neuroendoscopic approaches. Results of this qualitative survey provide consensus amongst the technology end-user community such that unambiguous goals and priorities may be defined. Systems integrating these advances could improve the safety and efficacy of endoscopic and endoscope-assisted neurosurgical approaches.

  18. Optical coherence tomography and autofluorescence findings in chronic phototoxic maculopathy secondary to snow-reflected solar radiation

    Directory of Open Access Journals (Sweden)

    Dhananjay Shukla

    2015-01-01

    Full Text Available A professional mountain trekker presented with gradual, moderate visual decline in one eye. The subnormal vision could not be explained by the examination of anterior and posterior segment of either eye, which was unremarkable. Optical coherence tomography and autofluorescence imaging revealed subtle defects in the outer retina, which correlated with the extent of visual disturbance. A novel presentation of retinal phototoxicity due to indirect solar radiation reflected from snow in inadequately protected eyes of a chronically exposed subject is reported.

  19. Optical coherence tomography and autofluorescence findings in chronic phototoxic maculopathy secondary to snow-reflected solar radiation.

    Science.gov (United States)

    Shukla, Dhananjay

    2015-05-01

    A professional mountain trekker presented with gradual, moderate visual decline in one eye. The subnormal vision could not be explained by the examination of anterior and posterior segment of either eye, which was unremarkable. Optical coherence tomography and autofluorescence imaging revealed subtle defects in the outer retina, which correlated with the extent of visual disturbance. A novel presentation of retinal phototoxicity due to indirect solar radiation reflected from snow in inadequately protected eyes of a chronically exposed subject is reported.

  20. Comparison of microscopic and endoscopic view of the internal acoustic meatus: A cadaveric study.

    Science.gov (United States)

    Montibeller, Guilherme Ramina; Hendrix, Philipp; Fries, Fabian N; Becker, Kurt W; Oertel, Joachim

    2018-04-01

    The endoscope is thought to provide an improved exposure of the internal acoustic meatus after retrosigmoid craniotomy for microsurgical resection of intrameatal tumors. The aim of this study is to quantify the differences in internal acoustic meatus (IAM) exposure comparing microscopic and endoscopic visualization. A retrosigmoid approach was performed on 5 cadaver heads. A millimeter gauge was introduced into the internal acoustic meatus, and examinations with a surgical microscope and 0°, 30° and 70° rigid endoscopes were performed. The extent of IAM depth visualized with the microscope and the different angled endoscopes were analyzed. The microscopic view allowed an average IAM depth visualization of 2.8 mm. The endoscope allowed an improved exposure of IAM in all cases. The 0°, 30° and 70° endoscopes permitted an exposure that was respectively 96% (5.5 mm), 139% (6.7 mm) and 200% (8.4 mm) more lateral than the microscopic view. Angled optics, however, provided an image distortion, specifically the 70° endoscope. The endoscope provides a superior visualization of the IAM compared to the microscope when using a retrosigmoid approach. The 30° endoscope represented an ideal compromise of superior visualization with marginal image distortion. Additional implementation of the endoscope into microsurgery of intrameatal tumors likely facilitates complete tumor removal and might spare facial and vestibulocochlear function. Clin. Anat. 31:398-403, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  1. New endoscope shaft for endoscopic transsphenoidal pituitary surgery.

    NARCIS (Netherlands)

    Lindert, E.J. van; Grotenhuis, J.A.

    2005-01-01

    OBJECTIVE: To describe a new endoscope shaft developed for suction-aspiration during endoscopic transsphenoidal pituitary surgery. METHODS: A custom-made shaft for a Wolf endoscope (Richard Wolf GmbH, Knittlingen, Germany) was developed with a height of 10 mm and a width of 5 mm, allowing an

  2. A Panoramic Wireless Endoscope System Design for the Application of Minimally Invasive Surgery

    Directory of Open Access Journals (Sweden)

    Chun-Hsiang Peng

    2014-05-01

    Full Text Available Minimally Invasive Surgery (MIS is the current trend in surgery. Compared to traditional surgery, MIS can substantially decrease recovery time and expenses needed by patients after surgeries, reduce pain during surgical procedures, and is highly regarded by physicians and patients. An endoscope is widely used in the diagnosis and treatments of various medical disciplines, such as hysteroscopy, laparoscopy, and colonoscopy, and have been adopted by many branches of medicine. However, the limited image field of MIS is often the most difficult obstacles faced by surgeons and medical students, especially to less experienced physicians and difficult surgical procedures; the limited field of view of endoscopic imaging does not provide a whole picture of the surgery area, making the procedures difficult and full of uncertainty. In light of this problem, we proposed a "Panoramic Wireless Endoscope System design", hoping to provide physicians with a wide field of view of the endoscopic image. We combine images captured from two parallel-mounted endoscope lenses into a single, wide-angle image, giving physicians a wider field of view and easier access to the surgical area. In addition, we developed a wireless transmission system so the image can be transmitted to various display platforms, eliminating the needs for excessive cabling on surgical tools and enable physicians to better operate on the patient. Finally, our system allows surgical assistants a better view of the operation process, and enables other physicians and nurses to remotely observe the process. Our experiment results have shown that we can increase the image to 152% of its original size. We used the PandaBoard ES platform with an ARM9 processor and 1G of onboard RAM, and continuously implementing animal trials to verify the reliability of our system.

  3. Advanced virtual endoscopy for endoscopic transsphenoidal pituitary surgery.

    Science.gov (United States)

    Wolfsberger, Stefan; Neubauer, André; Bühler, Katja; Wegenkittl, Rainer; Czech, Thomas; Gentzsch, Stephan; Böcher-Schwarz, Hans-Gerd; Knosp, Engelbert

    2006-11-01

    Virtual endoscopy (vE) is the navigation of a camera through a virtual anatomical space that is computationally reconstructed from radiological image data. Inside this three-dimensional space, arbitrary movements and adaptations of viewing parameters are possible. Thereby, vE can be used for noninvasive diagnostic purposes and for simulation of surgical tasks. This article describes the development of an advanced system of vE for endoscopic transsphenoidal pituitary surgery and its application to teaching, training, and in the routine clinical setting. The vE system was applied to a series of 35 patients with pituitary pathology (32 adenomas, three Rathke's cleft cysts) operated endoscopically via the transsphenoidal route at the Department of Neurosurgery of the Medical University Vienna between 2004 and 2006. The virtual endoscopic images correlated well with the intraoperative view. For the transsphenoidal approach, vE improved intraoperative orientation by depicting anatomical landmarks and variations. For planning a safe and tailored opening of the sellar floor, transparent visualization of the pituitary adenoma and the normal gland in relation to the internal carotid arteries was useful. According to our experience, vE can be a valuable tool for endoscopic transsphenoidal pituitary surgery for training purposes and preoperative planning. For the novice, it can act as a simulator for endoscopic anatomy and for training surgical tasks. For the experienced pituitary surgeon, vE can depict the individual patient's anatomy, and may, therefore, improve intraoperative orientation. By prospectively visualizing unpredictable anatomical variations, vE may increase the safety of this surgical procedure.

  4. Fundus autofluorescence and optical coherence tomographic findings in acute zonal occult outer retinopathy.

    Science.gov (United States)

    Fujiwara, Takamitsu; Imamura, Yutaka; Giovinazzo, Vincent J; Spaide, Richard F

    2010-09-01

    The purpose of this study was to investigate the fundus autofluorescence and optical coherence tomography findings in eyes with acute zonal occult outer retinopathy (AZOOR). A retrospective observational case series of the fundus autofluorescence and spectral domain optical coherence tomography in a series of patients with AZOOR. There were 19 eyes of 11 patients (10 women), who had a mean age of 49.1 +/- 13.9 years. Fundus autofluorescence abnormalities were seen in 17 of the 19 eyes, were more common in the peripapillary area, and were smaller in extent than the optical coherence tomography abnormalities. Nine eyes showed progression of hypoautofluorescence area during the mean follow-up of 69.7 months. The mean thickness of the photoreceptor layer at fovea was 177 microm in eyes with AZOOR, which was significantly thinner than controls (193 microm, P = 0.049). Abnormal retinal laminations were found in 12 eyes and were located over areas of loss of the photoreceptors. The subfoveal choroidal thickness was 243 microm, which is normal. Fundus autofluorescence abnormalities in AZOOR showed distinct patterns of retinal pigment epithelial involvement, which may be progressive. Thinning of photoreceptor cell layer with loss of the outer segments and abnormal inner retinal lamination in the context of a normal choroid are commonly found in AZOOR.

  5. Optical transfection using an endoscope-like system.

    Science.gov (United States)

    Ma, Nan; Gunn-Moore, Frank; Dholakia, Kishan

    2011-02-01

    Optical transfection is a powerful method for targeted delivery of therapeutic agents to biological cells. A tightly focused pulsed laser beam may transiently change the permeability of a cell membrane to facilitate the delivery of foreign genetic material into cells. We report the first realization of an endoscope-like integrated system for optical transfection. An imaging fiber (coherent optical fiber bundle) with ∼ 6000 cores (pixels) embedded in a fiber cladding of ∼ 300 μm in diameter, produces an image circle (area) of ∼ 270 μm diam. This imaging fiber, with an ordered axicon lens array chemically etched at its exit face, is used for the delivery of a femtosecond laser to the cell membrane for optical transfection along with subcellular resolution imaging. A microcapillary-based microfluidic system for localized drug delivery was also combined in this miniature, flexible system. Using this novel system, a plasmid transfection efficiency up to ∼ 72% was obtained for CHO-K1 cells. This endoscope-like system opens a range of exciting applications, in particular, in the targeted in vivo optical microsurgery area.

  6. Endoscopic Endonasal Approach for a Suprasellar Craniopharyngioma.

    Science.gov (United States)

    Zenonos, Georgios A; Snyderman, Carl H; Gardner, Paul A

    2018-04-01

    Objectives  The current video presents the nuances of an endoscopic endonasal approach to a suprasellar craniopharyngioma. Design  The video analyzes the presentation, preoperative workup and imaging, surgical steps and technical nuances of the surgery, the clinical outcome, and follow-up imaging. Setting  The patient was treated by a skull base team consisting of a neurosurgeon and an ENT surgeon, at a teaching academic institution. Participants  The case refers to a 67-year-old man who presented with vision loss and headaches, and was found to have a suprasellar mass, with imaging characteristics consistent with a craniopharyngioma. Main Outcome Measures  The main outcome measures consistent of the reversal of the patient symptoms (vision loss and headaches), the recurrence-free survival based on imaging, as well as the absence of any complications. Results  The patient's vision improved after the surgery; at his last follow-up there was no evidence of recurrence on imaging. Conclusions  The endoscopic endonasal approach is safe and effective in treating suprasellar craniopharyngiomas. The link to the video can be found at: https://youtu.be/p1VXbwnAWCo .

  7. Clinical endoscopic management and outcome of post-endoscopic sphincterotomy bleeding.

    Directory of Open Access Journals (Sweden)

    Wei-Chen Lin

    Full Text Available Post-endoscopic sphincterotomy bleeding is a common complication of biliary sphincterotomy, and the incidence varies from 1% to 48%. It can be challenging to localize the bleeder or to administer various interventions through a side-viewing endoscope. This study aimed to evaluate the risk factors of post-endoscopic sphincterotomy bleeding and the outcome of endoscopic intervention therapies. We retrospectively reviewed the records of 513 patients who underwent biliary sphincterotomy in Mackay Memorial Hospital between 2011 and 2016. The blood biochemistry, comorbidities, indication for sphincterotomy, severity of bleeding, endoscopic features of bleeder, and type of endoscopic therapy were analyzed. Post-endoscopic sphincterotomy bleeding occurred in 65 (12.6% patients. Forty-five patients had immediate bleeding and 20 patients had delayed bleeding. The multivariate analysis of risk factors associated with post-endoscopic sphincterotomy bleeding were liver cirrhosis (P = 0.029, end-stage renal disease (P = 0.038, previous antiplatelet drug use (P<0.001, and duodenal ulcer (P = 0.023. The complications of pancreatitis and cholangitis were higher in the bleeding group, with statistical significance. Delayed bleeding occurred within 1 to 7 days (mean, 2.5 days, and 60% (12/20 of the patients received endoscopic evaluation. In the delayed bleeding group, the successful hemostasis rate was 71.4% (5/7, and 65% (13/20 of the patients had ceased bleeding without endoscopic hemostasis therapy. Comparison of different therapeutic modalities showed that cholangitis was higher in patients who received epinephrine spray (P = 0.042 and pancreatitis was higher in patients who received epinephrine injection and electrocoagulation (P = 0.041 and P = 0.039 respectively. Clinically, post-endoscopic sphincterotomy bleeding and further endoscopic hemostasis therapy increase the complication rate of pancreatitis and cholangitis. Realizing the effectiveness of each

  8. Fundus Autofluorescence Features of Optic Disc Pit Related ...

    African Journals Online (AJOL)

    chorioretinopathy, retina telangiectasia and diffuse and macula retina dystrophies.[1,3‑8] These features give useful clinical and prognostic information, making FAF a desired day‑to‑day clinical tool. Fundus autoflorescence signals can be detected using 3 different systems, the Delori's fundus. Fundus Autofluorescence ...

  9. Autofluorescence of the fungus Morchella conica var. rigida

    Czech Academy of Sciences Publication Activity Database

    Žižka, Zdeněk; Gabriel, Jiří

    2011-01-01

    Roč. 56, č. 2 (2011), s. 166-169 ISSN 0015-5632 R&D Projects: GA ČR GA526/07/0620 Institutional research plan: CEZ:AV0Z50200510 Keywords : Autofluorescence * fungi * Morchella conica Subject RIV: EE - Microbiology, Virology Impact factor: 0.677, year: 2011

  10. Towards an ultra-thin medical endoscope: multimode fibre as a wide-field image transferring medium

    Science.gov (United States)

    Duriš, Miroslav; Bradu, Adrian; Podoleanu, Adrian; Hughes, Michael

    2018-03-01

    Multimode optical fibres are attractive for biomedical and industrial applications such as endoscopes because of the small cross section and imaging resolution they can provide in comparison to widely-used fibre bundles. However, the image is randomly scrambled by propagation through a multimode fibre. Even though the scrambling is unpredictable, it is deterministic, and therefore the scrambling can be reversed. To unscramble the image, we treat the multimode fibre as a linear, disordered scattering medium. To calibrate, we scan a focused beam of coherent light over thousands of different beam positions at the distal end and record complex fields at the proximal end of the fibre. This way, the inputoutput response of the system is determined, which then allows computational reconstruction of reflection-mode images. However, there remains the problem of illuminating the tissue via the fibre while avoiding back reflections from the proximal face. To avoid this drawback, we provide here the first preliminary confirmation that an image can be transferred through a 2x2 fibre coupler, with the sample at its distal port interrogated in reflection. Light is injected into one port for illumination and then collected from a second port for imaging.

  11. Scanning Laser Ophthalmoscope Measurement of Local Fundus Reflectance and Autofluorescence Changes Arising from Rhodopsin Bleaching and Regeneration

    OpenAIRE

    Morgan, Jessica I. W.; Pugh, Edward N.

    2013-01-01

    Rhodopsin was measured locally in the retina with a widely available, dual wavelength scanning laser ophthalmoscope that does not require pupil dilation. Increased autofluorescence attendant bleaching arises largely from transient removal of rhodopsin's screening of autofluorescent fluorochromes.

  12. Sub-cellular trafficking of phytochemicals explored using auto-fluorescent compounds in maize cells

    Directory of Open Access Journals (Sweden)

    Grotewold Erich

    2003-12-01

    Full Text Available Abstract Background Little is known regarding the trafficking mechanisms of small molecules within plant cells. It remains to be established whether phytochemicals are transported by pathways similar to those used by proteins, or whether the expansion of metabolic pathways in plants was associated with the evolution of novel trafficking pathways. In this paper, we exploited the induction of green and yellow auto-fluorescent compounds in maize cultured cells by the P1 transcription factor to investigate their targeting to the cell wall and vacuole, respectively. Results We investigated the accumulation and sub-cellular localization of the green and yellow auto-fluorescent compounds in maize BMS cells expressing the P1 transcription factor from an estradiol inducible promoter. We established that the yellow fluorescent compounds accumulate inside the vacuole in YFBs that resemble AVIs. The green fluorescent compounds accumulate initially in the cytoplasm in large spherical GFBs. Cells accumulating GFBs also contain electron-dense structures that accumulate initially in the ER and which later appear to fuse with the plasma membrane. Structures resembling the GFBs were also observed in the periplasmic space of plasmolized cells. Ultimately, the green fluorescence accumulates in the cell wall, in a process that is insensitive to the Golgi-disturbing agents BFA and monensin. Conclusions Our results suggest the presence of at least two distinct trafficking pathways, one to the cell wall and the other to the vacuole, for different auto-fluorescent compounds induced by the same transcription factor in maize BMS cells. These compartments represent two of the major sites of accumulation of phenolic compounds characteristic of maize cells. The secretion of the green auto-fluorescent compounds occurs by a pathway that does not involve the TGN, suggesting that it is different from the secretion of most proteins, polysaccharides or epicuticular waxes. The

  13. Fluorescence-Raman Dual Modal Endoscopic System for Multiplexed Molecular Diagnostics

    Science.gov (United States)

    Jeong, Sinyoung; Kim, Yong-Il; Kang, Homan; Kim, Gunsung; Cha, Myeong Geun; Chang, Hyejin; Jung, Kyung Oh; Kim, Young-Hwa; Jun, Bong-Hyun; Hwang, Do Won; Lee, Yun-Sang; Youn, Hyewon; Lee, Yoon-Sik; Kang, Keon Wook; Lee, Dong Soo; Jeong, Dae Hong

    2015-03-01

    Optical endoscopic imaging, which was recently equipped with bioluminescence, fluorescence, and Raman scattering, allows minimally invasive real-time detection of pathologies on the surface of hollow organs. To characterize pathologic lesions in a multiplexed way, we developed a dual modal fluorescence-Raman endomicroscopic system (FRES), which used fluorescence and surface-enhanced Raman scattering nanoprobes (F-SERS dots). Real-time, in vivo, and multiple target detection of a specific cancer was successful, based on the fast imaging capability of fluorescence signals and the multiplex capability of simultaneously detected SERS signals using an optical fiber bundle for intraoperative endoscopic system. Human epidermal growth factor receptor 2 (HER2) and epidermal growth factor receptor (EGFR) on the breast cancer xenografts in a mouse orthotopic model were successfully detected in a multiplexed way, illustrating the potential of FRES as a molecular diagnostic instrument that enables real-time tumor characterization of receptors during routine endoscopic procedures.

  14. Endoscopic Management of a Primary Duodenal Carcinoid Tumor

    Directory of Open Access Journals (Sweden)

    Albin Abraham

    2012-03-01

    Full Text Available Carcinoids are rare, slow-growing tumors originating from a variety of different neuroendocrine cell types. They are identified histologically by their affinity for silver salts and by positive reactions to neuroendocrine markers such as neuron-specific enolase, synaptophysin and chromogranin. They can present with various clinical symptoms and are difficult to diagnose. We present the case of a 43-year-old woman who was referred for evaluation of anemia. Upper endoscopy showed a duodenal bulb mass around 1 cm in size. Histopathological and immunohistochemistry staining were consistent with the diagnosis of a carcinoid tumor. Further imaging and endoscopic studies showed no other synchronous carcinoid lesions. Endoscopic ultrasound (EUS revealed a 1 cm lesion confined to the mucosa and no local lymphadenopathy. Successful endoscopic mucosal resection of the mass was performed. Follow-up surveillance 6 months later with EUS and Octreoscan revealed no new lesions suggestive of recurrence. No consensus guidelines exist for the endoscopic management of duodenal carcinoid tumors. However, endoscopic resection is safe and preferred for tumors measuring 1 cm or less with no evidence of invasion of the muscularis layer.

  15. Estimating Bacterial and Cellular Load in FCFM Imaging

    Directory of Open Access Journals (Sweden)

    Sohan Seth

    2018-01-01

    Full Text Available We address the task of estimating bacterial and cellular load in the human distal lung with fibered confocal fluorescence microscopy (FCFM. In pulmonary FCFM some cells can display autofluorescence, and they appear as disc like objects in the FCFM images, whereas bacteria, although not autofluorescent, appear as bright blinking dots when exposed to a targeted smartprobe. Estimating bacterial and cellular load becomes a challenging task due to the presence of background from autofluorescent human lung tissues, i.e., elastin, and imaging artifacts from motion etc. We create a database of annotated images for both these tasks where bacteria and cells were annotated, and use these databases for supervised learning. We extract image patches around each pixel as features, and train a classifier to predict if a bacterium or cell is present at that pixel. We apply our approach on two datasets for detecting bacteria and cells respectively. For the bacteria dataset, we show that the estimated bacterial load increases after introducing the targeted smartprobe in the presence of bacteria. For the cell dataset, we show that the estimated cellular load agrees with a clinician’s assessment.

  16. Virtualized endoscope system. An application of virtual reality technology to diagnostic aid

    International Nuclear Information System (INIS)

    Mori, Kensaku; Urano, Akihiro; Toriwaki, Jun-ichiro; Hasegawa, Jun-ichi; Anno, Hirofumi; Katada, Kazuhiro.

    1996-01-01

    In this paper we propose a new medical image processing system called 'Virtualized Endoscope System (VES)', which can examine the inside of a virtualized human body. The virtualized human body is a 3-D digital image which is taken by such as X-ray CT scanner or MRI scanner. VES consists of three modules; (1) imaging, (2) segmentation and reconstruction and (3) interactive operation. The interactive operation module has following three major functions; (a) display of, (b) measurement from, and (c) manipulation to the virtualized human body. The user of the system can observe freely both the inside and the outside of a target organ from any point and any direction freely, and can perform necessary measurement interactively concerning angle and length at any time during observation. VES enables to observe repeatedly an area where the real endoscope can not enter without pain from any direction which the real endoscope can not. We applied this system to real 3-D X-ray CT images and obtained good result. (author)

  17. The role of contrast-enhanced endoscopic ultrasound in pancreatic adenocarcinoma

    DEFF Research Database (Denmark)

    Saftoiu, Adrian; Vilmann, Peter; Bhutani, Manoop S

    2016-01-01

    contrast agents for early detection, tridimensional and fusion techniques for enhanced staging and resectability assessment but also novel applications of perfusion imaging for monitoring ablative therapy, improved local detection through EUS-guided sampling of portal vein flow or enhanced drug delivery......Contrast-enhanced endoscopic ultrasound (CE-EUS) allows characterization, differentiation, and staging of focal pancreatic masses. The method has a high sensitivity and specificity for the diagnosis of pancreatic adenocarcinoma which is visualized as hypo-enhanced as compared to the rest...... of the parenchyma while chronic pancreatitis and neuroendocrine tumors are generally either iso-enhanced or hyper-enhanced. The development of contrast-enhanced low mechanical index harmonic imaging techniques used in real time during endoscopic ultrasound (EUS) allowed perfusion imaging and the quantification...

  18. Peroperative optical autofluorescence biopsy-verification of its diagnostic potential

    Czech Academy of Sciences Publication Activity Database

    Ducháč, V.; Zavadil, Jiří; Vránová, J.; Jirásek, T.; Štukavec, J.; Horák, L.

    2011-01-01

    Roč. 26, č. 3 (2011), s. 325-333 ISSN 0268-8921 Institutional research plan: CEZ:AV0Z20670512 Keywords : Autofluorescence spectroscopy * Colorectal cancer * Optical fibres Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.004, year: 2011

  19. Ultra-widefield fundus autofluorescence in age-related macular degeneration.

    Directory of Open Access Journals (Sweden)

    Abhilash Guduru

    Full Text Available Establish accuracy and reproducibility of subjective grading in ultra-widefield fundus autofluorescence (FAF imaging in patients with age-related macular degeneration (AMD, and determine if an association exists between peripheral FAF abnormalities and AMD.This was a prospective, single-blinded case-control study. Patients were consecutively recruited for the study. Patients were excluded if there was a history of prior or active ocular pathology other than AMD or image quality was insufficient for analysis as determined by two independent graders. Control patients were those without any evidence of AMD or other ophthalmic disease apart from cataract. Using the Optos 200Tx (Optos, Marlborough, MA, USA, a ResMax central macula and an ultra-widefield peripheral retina image was taken for each eye in both normal color and short wavelength FAF. Ultra-widefield photographs were modified to mask the macula. Each ResMax and ultra-widefield image was independently graded by two blinded investigators.There were 28 AMD patients and 11 controls. There was a significant difference in the average age between AMD patients and control groups (80 versus 64, respectively P<0.001. There was moderate, statistically significant agreement between observers regarding image interpretation (78.4%, K = 0.524, P<0.001, and 69.0% (K = 0.49, P<0.001 agreement between graders for FAF abnormality patterns. Patients with AMD were at greater risk for peripheral FAF abnormalities (OR: 3.43, P = 0.019 and patients with FAF abnormalities on central macular ResMax images were at greater risk of peripheral FAF findings (OR: 5.19, P = 0.017.Subjective interpretation of FAF images has moderate reproducibility and validity in assessment of peripheral FAF abnormalities. Peripheral FAF abnormalities are seen in both AMD and control patients. Those with AMD, poor visual acuity, and macular FAF abnormalities are at greater risk.

  20. MACULAR ATROPHY FINDINGS BY OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY COMPARED WITH FUNDUS AUTOFLUORESCENCE IN TREATED EXUDATIVE AGE-RELATED MACULAR DEGENERATION.

    Science.gov (United States)

    Takasago, Yukari; Shiragami, Chieko; Kobayashi, Mamoru; Osaka, Rie; Ono, Aoi; Yamashita, Ayana; Tsujikawa, Akitaka; Hirooka, Kazuyuki

    2017-11-28

    To compare the areas of choriocapillaris (CC) nonperfusion and macular atrophy (MA) in treated exudative age-related macular degeneration. This was a prospective, observational, cross-sectional study. Forty-four eyes exhibiting MA (42 patients with age-related macular degeneration), with a dry macula, underwent fundus autofluorescence and optical coherence tomography angiography. The area of MA detected by fundus autofluorescence and CC nonperfusion detected by optical coherence tomography angiography was measured using image analysis software. The rates of concordance between the MA and CC nonperfusion areas were calculated. We qualitatively and quantitatively compared the areas of MA and CC nonperfusion in age-related macular degeneration eyes. The mean areas of MA and CC nonperfusion were 5.95 ± 4.50 mm and 10.66 ± 7.05 mm, respectively (paired t-test, P autofluorescence matching optical coherence tomography angiography showed that the CC nonperfusion area was almost included in the MA area. The mean concordance rate for the MA area inside the CC nonperfusion area was 87.7 ± 13.9%. The MA and CC nonperfusion areas markedly overlapped. The area of CC nonperfusion correlated with the MA area. Choroidal ischemia might be involved in the pathogenesis of MA in treated age-related macular degeneration.This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

  1. [Inspecting the cochlear scala tympanic with flexible and semi-flexible micro-endoscope].

    Science.gov (United States)

    Zhang, Daoxcing; Zhang, Yankun

    2006-02-01

    Flexible and semi-flexible micro-endoscopes were used in cochlear scala tympani inspection , to explore their application in inner ear examination. Fifteen profound hearing loss patients preparing for cochlear implant were included in this study. During the operation, micro-endoscopy was performed after opening the cochlear scala tympani. And 1 mm diameter semi-flexible micro-endoscope could go as deep as 9 mm into the cochlear scala tympani, while 0. 5 mm diameter flexible micro-endoscope could go as deep as 25 mm. The inspecting results were compared with video recording. Using 0.5 mm flexible micro-endoscope, we canould check cochlear scala tympani with depth range of 15-25 mm, but the video imaging was not clear enough to examine the microstructure in the cochlear. With 1 mm diameter semi-flexible micro-endoscope, we could reach 9 mm deep into the cochlear. During the examination, we found 3 cases with calcification deposit in osseous spiral lamina, l case with granulation tissue in the lateral wall of scala tympani, no abnormal findings in the other 11 cases. Inspecting the cochlear scala tympani with 0.5 mm flexible micro-endoscope, even though we can reach the second circuit of the cochlear, it is difficult to find the pathology in the cochlear because of the poor video imaging. With 1 mm semi-flexible micro-endoscope, we can identify the microstructure of the cochlear clearly and find the pathologic changes, but the inserting depth was limited to 9 mm with limitation to examine the whole cochlear.

  2. Effect of metalloporphyrins on red autofluorescence from oral bacteria

    NARCIS (Netherlands)

    Volgenant, C.M.C.; van der Veen, M.H.; de Soet, J.J.; ten Cate, J.M.

    2013-01-01

    The aim of this study was to assess the red autofluorescence from bacterial species related to dental caries and periodontitis in the presence of different nutrients in the growth medium. Bacteria were grown anaerobically on tryptic soy agar (TSA) supplemented with nutrients, including

  3. Endoscopic anatomy of the orbital floor and maxillary sinus.

    Science.gov (United States)

    Moore, Corey C; Bromwich, Matthew; Roth, Kathy; Matic, Damir B

    2008-01-01

    Endoscopic repair of orbital blow-out fractures could become a predictable and efficient treatment alternative to traditional methods. However, maxillary sinus endoscopy provides a complex and disorienting view of the orbital floor. To be a useful and consistent technique for providing access to the orbital floor, specific knowledge of maxillary endoscopic anatomy is required. The purpose of the study was to provide an anatomic description of the orbital floor via the endoscopic approach. Objectives include defining consistent landmarks for use in endoscopic repair of orbital floor fractures. Using 0- and 30-degree rigid endoscopes, 6 fresh cadavers (12 maxillary sinuses) were examined via a standard Caldwell-Luc approach. Computed tomographic scans, plastic molds, and digital images were used to compare observable averages within bony anatomy. Potential bony landmarks were correlated with soft-tissue anatomy in fresh specimens. The maxillary ostium, orbital floor, and lateral ethmoid air cells were visualized, and their structures were described. Observations were made in relation to the anatomy of the orbital floor and maxillary sinus, including fracture pattern and force transmission pathways. An "orbitomaxillary" sinus bony thickening was identified and described for the first time. This study provides the basis for further refinement of surgical technique and opens the door for future clinical trials using endoscopic repair.

  4. Endoscopic Therapeutic Approach for Dysplasia in Inflammatory Bowel Disease

    Directory of Open Access Journals (Sweden)

    Sung Noh Hong

    2017-09-01

    Full Text Available Long-standing intestinal inflammation in patients with inflammatory bowel disease (IBD induces dysplastic change in the intestinal mucosa and increases the risk of subsequent colorectal cancer. The evolving endoscopic techniques and technologies, including dye spraying methods and high-definition images, have been replacing random biopsies and have been revealed as more practical and efficient for detection of dysplasia in IBD patients. In addition, they have potential usefulness in detailed characterization of lesions and in the assessment of endoscopic resectability. Most dysplastic lesions without an unclear margin, definite ulceration, non-lifting sign, and high index of malignant change with suspicion for lymph node or distant metastases can be removed endoscopically. However, endoscopic resection of dysplasia in chronic IBD patients is usually difficult because it is often complicated by submucosal fibrosis. In patients with dysplasias that demonstrate submucosa fibrosis or a large size (≥20 mm, endoscopic submucosal dissection (ESD or ESD with snaring (simplified or hybrid ESD is an alternative option and may avoid a colectomy. However, a standardized endoscopic therapeutic approach for dysplasia in IBD has not been established yet, and dedicated specialized endoscopists with interest in IBD are needed to fully investigate recent emerging techniques and technologies.

  5. Endoscopic Ultrasound Elastography: Current Clinical Use in Pancreas.

    Science.gov (United States)

    Mondal, Utpal; Henkes, Nichole; Patel, Sandeep; Rosenkranz, Laura

    2016-08-01

    Elastography is a newer technique for the assessment of tissue elasticity using ultrasound. Cancerous tissue is known to be stiffer (hence, less elastic) than corresponding healthy tissue, and as a result, could be identified in an elasticity-based imaging. Ultrasound elastography has been used in the breast, thyroid, and cervix to differentiate malignant from benign neoplasms and to guide or avoid unnecessary biopsies. In the liver, elastography has enabled a noninvasive and reliable estimate of fibrosis. Endoscopic ultrasound has become a robust diagnostic and therapeutic tool for the management of pancreatic diseases. The addition of elastography to endoscopic ultrasound enabled further characterization of pancreas lesions, and several European and Asian studies have reported encouraging results. The current clinical role of endoscopic ultrasound elastography in the management of pancreas disorders and related literature are reviewed.

  6. Application of Autofluorescence for Analysis of Medicinal Plants

    Directory of Open Access Journals (Sweden)

    Victoria V. Roshchina

    2017-01-01

    Full Text Available Autofluorescence of secondary compounds contained in plant secretory cells may be applied to the analysis of medicinal plants for pharmacy. Emission and prevailing fluorescent pharmaceuticals have been estimated in several models of species such as Salvia officinalis, Berberis vulgaris, Humulus lupulus, and Matricaria chamomilla, by luminescence microscopy, microspectrofluorimetry, and confocal microscopy.

  7. Skin color independent assessment of aging using skin autofluorescence

    NARCIS (Netherlands)

    Koetsier, M.; Nur, Erfan; Chunmao, Han; Lutgers, Helen L.; Links, Thera P.; Smit, Andries J.; Rakhorst, Gerhard; Graaff, Reindert

    2010-01-01

    Skin autofluorescence (AF) for the non-invasive assessment of the amount of accumulated tissue Advanced Glycation Endproducts (AGEs) increases with aging. In subjects with darker skin colors, measurements typically result in lower AF values than in subjects with fair skin colors, e.g. due to

  8. Skin color independent assessment of aging using skin autofluorescence

    NARCIS (Netherlands)

    Koetsier, M.; Nur, E.; Chunmao, H.; Lutgers, H.L.; Links, T.P.; Smit, A.J.; Rakhorst, G.; de Graaff, R.

    2010-01-01

    Skin autofluorescence (AF) for the non-invasive assessment of the amount of accumulated tissue Advanced Glycation Endproducts (AGEs) increases with aging. In subjects with darker skin colors, measurements typically result in lower AF values than in subjects with fair skin colors, e. g. due to

  9. Intravascular ultrasonic-photoacoustic (IVUP) endoscope with 2.2-mm diameter catheter for medical imaging.

    Science.gov (United States)

    Bui, Nhat Quang; Hlaing, Kyu Kyu; Nguyen, Van Phuc; Nguyen, Trung Hau; Oh, Yun-Ok; Fan, Xiao Feng; Lee, Yong Wook; Nam, Seung Yun; Kang, Hyun Wook; Oh, Junghwan

    2015-10-01

    Intravascular ultrasound (IVUS) imaging is extremely important for detection and characterization of high-risk atherosclerotic plaques as well as gastrointestinal diseases. Recently, intravascular photoacoustic (IVPA) imaging has been used to differentiate the composition of biological tissues with high optical contrast and ultrasonic resolution. The combination of these imaging techniques could provide morphological information and molecular screening to characterize abnormal tissues, which would help physicians to ensure vital therapeutic value and prognostic significance for patients before commencing therapy. In this study, integration of a high-frequency IVUS imaging catheter (45MHz, single-element, unfocused, 0.7mm in diameter) with a multi-mode optical fiber (0.6mm in core diameter, 0.22 NA), an integrated intravascular ultrasonic-photoacoustic (IVUP) imaging catheter, was developed to provide spatial and functional information on light distribution in a turbid sample. Simultaneously, IVUS imaging was co-registered to IVPA imaging to construct 3D volumetric sample images. In a phantom study, a polyvinyl alcohol (PVA) tissue-mimicking arterial vessel phantom with indocyanine green (ICG) and methylene blue (MB) inclusion was used to demonstrate the feasibility of mapping the biological dyes, which are used in cardiovascular and cancer diagnostics. For the ex vivo study, an excised sample of pig intestine with ICG was utilized to target the biomarkers present in the gastrointestinal tumors or the atherosclerotic plaques with the proposed hybrid technique. The results indicated that IVUP endoscope with the 2.2-mm diameter catheter could be a useful tool for medical imaging. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Coherent anti-Stokes Raman scattering rigid endoscope toward robot-assisted surgery.

    Science.gov (United States)

    Hirose, K; Aoki, T; Furukawa, T; Fukushima, S; Niioka, H; Deguchi, S; Hashimoto, M

    2018-02-01

    Label-free visualization of nerves and nervous plexuses will improve the preservation of neurological functions in nerve-sparing robot-assisted surgery. We have developed a coherent anti-Stokes Raman scattering (CARS) rigid endoscope to distinguish nerves from other tissues during surgery. The developed endoscope, which has a tube with a diameter of 12 mm and a length of 270 mm, achieved 0.91% image distortion and 8.6% non-uniformity of CARS intensity in the whole field of view (650 μm diameter). We demonstrated CARS imaging of a rat sciatic nerve and visualization of the fine structure of nerve fibers.

  11. Correlation between peripapillary retinal nerve fiber layer thickness and fundus autofluorescence in primary open-angle glaucoma

    Directory of Open Access Journals (Sweden)

    Reznicek L

    2013-09-01

    Full Text Available Lukas Reznicek,* Florian Seidensticker,* Thomas Mann, Irene Hübert, Alexandra Buerger, Christos Haritoglou, Aljoscha S Neubauer, Anselm Kampik, Christoph Hirneiss, Marcus Kernt Department of Ophthalmology, Ludwig-Maximilians-University, Munich, Germany *These authors contributed equally to this work Purpose: To investigate the relationship between retinal nerve fiber layer (RNFL thickness and retinal pigment epithelium alterations in patients with advanced glaucomatous visual field defects. Methods: A consecutive, prospective series of 82 study eyes with primary open-angle glaucoma and advanced glaucomatous visual field defects were included in this study. All study participants underwent a full ophthalmic examination followed by visual field testing with standard automated perimetry as well as spectral-domain optical coherence tomography (SD-OCT for peripapillary RNFL thickness and Optos wide-field fundus autofluorescence (FAF images. A pattern grid with corresponding locations between functional visual field sectors and structural peripapillary RNFL thickness was aligned to the FAF images at corresponding location. Mean FAF intensity (range: 0 = black and 255 = white of each evaluated sector (superotemporal, temporal, inferotemporal, inferonasal, nasal, superonasal was correlated with the corresponding peripapillary RNFL thickness obtained with SD-OCT. Results: Correlation analyses between sectoral RNFL thickness and standardized FAF intensity in the corresponding topographic retina segments revealed partly significant correlations with correlation coefficients ranging between 0.004 and 0.376 and were statistically significant in the temporal inferior central field (r = 0.324, P = 0.036 and the nasal field (r = 0.376, P = 0.014. Conclusion: Retinal pigment epithelium abnormalities correlate with corresponding peripapillary RNFL damage, especially in the temporal inferior sector of patients with advanced glaucomatous visual field defects. A

  12. A discriminative structural similarity measure and its application to video-volume registration for endoscope three-dimensional motion tracking.

    Science.gov (United States)

    Luo, Xiongbiao; Mori, Kensaku

    2014-06-01

    Endoscope 3-D motion tracking, which seeks to synchronize pre- and intra-operative images in endoscopic interventions, is usually performed as video-volume registration that optimizes the similarity between endoscopic video and pre-operative images. The tracking performance, in turn, depends significantly on whether a similarity measure can successfully characterize the difference between video sequences and volume rendering images driven by pre-operative images. The paper proposes a discriminative structural similarity measure, which uses the degradation of structural information and takes image correlation or structure, luminance, and contrast into consideration, to boost video-volume registration. By applying the proposed similarity measure to endoscope tracking, it was demonstrated to be more accurate and robust than several available similarity measures, e.g., local normalized cross correlation, normalized mutual information, modified mean square error, or normalized sum squared difference. Based on clinical data evaluation, the tracking error was reduced significantly from at least 14.6 mm to 4.5 mm. The processing time was accelerated more than 30 frames per second using graphics processing unit.

  13. Qualitative and quantitative characteristics of near-infrared autofluorescence in diabetic macular edema.

    Science.gov (United States)

    Yoshitake, Shin; Murakami, Tomoaki; Horii, Takahiro; Uji, Akihito; Ogino, Ken; Unoki, Noriyuki; Nishijima, Kazuaki; Yoshimura, Nagahisa

    2014-05-01

    To study the characteristics of near-infrared autofluorescence (NIR-AF) imaging and its association with spectral-domain optical coherence tomography (SD-OCT) findings and logarithm of the minimal angle of resolution (logMAR) visual acuity (VA) in diabetic macular edema (DME). Retrospective, observational, cross-sectional study. One hundred twenty-one consecutive eyes of 87 patients with center-involved DME for whom NIR-AF and SD-OCT images of sufficient quality were obtained. The NIR-AF images were acquired using Heidelberg Retina Angiograph 2 (Heidelberg Engineering, Heidelberg, Germany), and sectional retinal images were obtained using Spectralis OCT (Heidelberg Engineering). The presence of a mosaic pattern and cystoid signs were determined qualitatively. We quantified the average fluorescence intensity in the central 1-mm subfield. The characteristics of the NIR-AF images were compared with the OCT findings and logMAR VA. Qualitative and quantitative characteristics of the NIR-AF images and their association with SD-OCT findings and logMAR VA. Fifty-seven eyes with a mosaic pattern in the NIR-AF macular images had worse logMAR VA (0.355±0.239 vs. 0.212±0.235; P = 0.001), a thicker central subfield (CSF) (530±143 μm vs. 438±105 μm; P qualitative and quantitative NIR-AF characteristics in the macula indicated the clinical relevance and suggested the pathogenesis in DME. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  14. Ultrahigh speed endoscopic optical coherence tomography using micromotor imaging catheter and VCSEL technology.

    Science.gov (United States)

    Tsai, Tsung-Han; Potsaid, Benjamin; Tao, Yuankai K; Jayaraman, Vijaysekhar; Jiang, James; Heim, Peter J S; Kraus, Martin F; Zhou, Chao; Hornegger, Joachim; Mashimo, Hiroshi; Cable, Alex E; Fujimoto, James G

    2013-07-01

    We developed a micromotor based miniature catheter with an outer diameter of 3.2 mm for ultrahigh speed endoscopic swept source optical coherence tomography (OCT) using a vertical cavity surface-emitting laser (VCSEL) at a 1 MHz axial scan rate. The micromotor can rotate a micro-prism at several hundred frames per second with less than 5 V drive voltage to provide fast and stable scanning, which is not sensitive to the bending of the catheter. The side-viewing probe can be pulled back to acquire a three-dimensional (3D) data set covering a large area on the specimen. The VCSEL provides a high axial scan rate to support dense sampling under high frame rate operation. Using a high speed data acquisition system, in vivo 3D-OCT imaging in the rabbit GI tract and ex vivo imaging of a human colon specimen with 8 μm axial resolution, 8 μm lateral resolution and 1.2 mm depth range in tissue at a frame rate of 400 fps was demonstrated.

  15. Endoscopic root canal treatment.

    Science.gov (United States)

    Moshonov, Joshua; Michaeli, Eli; Nahlieli, Oded

    2009-10-01

    To describe an innovative endoscopic technique for root canal treatment. Root canal treatment was performed on 12 patients (15 teeth), using a newly developed endoscope (Sialotechnology), which combines an endoscope, irrigation, and a surgical microinstrument channel. Endoscopic root canal treatment of all 15 teeth was successful with complete resolution of all symptoms (6-month follow-up). The novel endoscope used in this study accurately identified all microstructures and simplified root canal treatment. The endoscope may be considered for use not only for preoperative observation and diagnosis but also for active endodontic treatment.

  16. Visual servoing in medical robotics: a survey. Part I: endoscopic and direct vision imaging - techniques and applications.

    Science.gov (United States)

    Azizian, Mahdi; Khoshnam, Mahta; Najmaei, Nima; Patel, Rajni V

    2014-09-01

    Intra-operative imaging is widely used to provide visual feedback to a clinician when he/she performs a procedure. In visual servoing, surgical instruments and parts of tissue/body are tracked by processing the acquired images. This information is then used within a control loop to manoeuvre a robotic manipulator during a procedure. A comprehensive search of electronic databases was completed for the period 2000-2013 to provide a survey of the visual servoing applications in medical robotics. The focus is on medical applications where image-based tracking is used for closed-loop control of a robotic system. Detailed classification and comparative study of various contributions in visual servoing using endoscopic or direct visual images are presented and summarized in tables and diagrams. The main challenges in using visual servoing for medical robotic applications are identified and potential future directions are suggested. 'Supervised automation of medical robotics' is found to be a major trend in this field. Copyright © 2013 John Wiley & Sons, Ltd.

  17. Pneumoretroperitoneum and Sepsis After Transanal Endoscopic Resection of a Rectal Lateral Spreading Tumor

    Science.gov (United States)

    Coura, Marcelo de Melo Andrade; de Almeida, Romulo Medeiros; Moreira, Natascha Mourão; de Sousa, João Batista; de Oliveira, Paulo Gonçalves

    2017-01-01

    Transanal endoscopic microsurgery is considered a safe, appropriate, and minimally invasive approach, and complications after endoscopic microsurgery are rare. We report a case of sepsis and pneumoretroperitoneum after resection of a rectal lateral spreading tumor. The patient presented with rectal mucous discharge. Colonoscopy revealed a rectal lateral spreading tumor. The patient underwent an endoscopic transanal resection of the lesion. He presented with sepsis of the abdominal focus, and imaging tests revealed pneumoretroperitoneum. A new surgical intervention was performed with a loop colostomy. Despite the existence of other reports on pneumoretroperitoneum after transanal endoscopic microsurgery, what draws attention to this case is the association with sepsis. PMID:28761873

  18. The Spectrum of Fundus Autofluorescence Findings in Birdshot Chorioretinopathy

    Directory of Open Access Journals (Sweden)

    GianPaolo Giuliari

    2009-01-01

    Full Text Available Objective. To describe the diverse patterns observed with the use of autofluorescence fundus photography (FAF in patients with Birdshot chorioretinopathy (BSCR. Methods. A chart review of patients with BSCR seen at the Massachusetts Eye Research and Surgery Institution, who had autofluorescence fundus photography. The data obtained included age, gender, presence of the HLA-A29 haplotype, and current treatment. Results. Eighteen eyes with HLA-A29 associated BSCR were included. Four eyes presented with active inflammation. Correspondence of the lesions noted in the colour fundus photograph was observed in 3 eyes which were more easily identified with the FAF. Fifteen eyes had fundus lesions more numerous and evident in the FAF than in the colour fundus photograph. Conclusion. Because FAF testing provides valuable insight into the metabolic state of the PR/RPE-complex, it may serve as a useful noninvasive assessment tool in patients with posterior uveitis in which the outer retina-RPE-choriocapillaries-complex is involved.

  19. [Transsphenoidal endoscopic endonasal approach for the surgery of pituitary abscess].

    Science.gov (United States)

    Yu, Huanxin; Liu, Gang

    2014-01-01

    To evaluate the effectiveness of transsphenoidal endoscopic endonasal approach for the surgery of pituitary abscess. Eighteen pathologically diagnosed pituitary abscess were resected through transsphenoidal endoscopic endonasal approach at Tianjing Huanhu hospital between January 2000 and December 2011.Retrospective analysis was done upon clinical presentations and imaging features. There were 6 males and 12 females. The average age was 48.5 years old and the average disease course was 5.8 years. The typical clinical manifestations included headache (13 cases), pituitary dysfunction (10 cases), Diabetes Insipidus (4 cases) visual interference (8 cases) and fever (4 cases). All cases were resected by transsphenoidal endoscopic endonasal approach with general anesthesia. The postoperative symptoms and follow-up results were recorded. All patients were followed up from 6 months to 6 years. Postoperatively, headache was recovered in 13 cases, visual was improved in 6 cases, hypopituitarism was relieved in 8 cases and polyuria was disappeared in 3 cases. One case was recurrent and cured by transsphenoidal endoscopic endonasal approach. Transsphenoidal endoscopic endonasal approach for the surgery of pituitary abscess is effective.

  20. Imaging in the Evaluation of Endoscopic or Surgical Treatment for Achalasia

    Directory of Open Access Journals (Sweden)

    Diego Palladino

    2016-01-01

    Full Text Available Purpose. Aim of the study is to evaluate the efficacy of the endoscopic (pneumatic dilation versus surgical (Heller myotomy treatment in patients affected by esophageal achalasia using barium X-ray examination of the digestive tract performed before and after the treatment. Materials and Methods. 19 patients (10 males and 9 females were enrolled in this study; each patient underwent a barium X-ray examination to evaluate the esophageal diameter and the height of the barium column before and after endoscopic or surgical treatment. Results. The mean variation of oesophageal diameter before and after treatment is −2.1 mm for surgery and 1.74 mm for pneumatic dilation (OR 0.167, CI 95% 0.02–1.419, and P: 0.10. The variations of all variables, with the exception of the oesophageal diameter variation, are strongly related to the treatment performed. Conclusions. The barium X-ray study of the digestive tract, performed before and after different treatment approaches, demonstrates that the surgical treatment has to be considered as the treatment of choice of achalasia, reserving endoscopic treatment to patients with high operative risk and refusing surgery.

  1. Optical fiber-based full Mueller polarimeter for endoscopic imaging using a two-wavelength simultaneous measurement method.

    Science.gov (United States)

    Vizet, Jérémy; Manhas, Sandeep; Tran, Jacqueline; Validire, Pierre; Benali, Abdelali; Garcia-Caurel, Enric; Pierangelo, Angelo; De Martino, Antonello; Pagnoux, Dominique

    2016-07-01

    This paper reports a technique based on spectrally differential measurement for determining the full Mueller matrix of a biological sample through an optical fiber. In this technique, two close wavelengths were used simultaneously, one for characterizing the fiber and the other for characterizing the assembly of fiber and sample. The characteristics of the fiber measured at one wavelength were used to decouple its contribution from the measurement on the assembly of fiber and sample and then to extract sample Mueller matrix at the second wavelength. The proof of concept was experimentally validated by measuring polarimetric parameters of various calibrated optical components through the optical fiber. Then, polarimetric images of histological cuts of human colon tissues were measured, and retardance, diattenuation, and orientation of the main axes of fibrillar regions were displayed. Finally, these images were successfully compared with images obtained by a free space Mueller microscope. As the reported method does not use any moving component, it offers attractive integration possibilities with an endoscopic probe.

  2. In-vivo fluorescence detection and imaging of porphyrin-producing bacteria in the human skin and in the oral cavity for diagnosis of acne vulgaris, caries, and squamous cell carcinoma

    Science.gov (United States)

    Koenig, Karsten; Schneckenburger, Herbert; Hemmer, Joerg; Tromberg, Bruce J.; Steiner, Rudolf W.

    1994-05-01

    Certain bacteria are able to synthesize metal-free fluorescent porphyrins and can therefore be detected by sensitive autofluorescence measurements in the red spectral region. The porphyrin-producing bacterium Propionibacterium acnes, which is involved in the pathogenesis of acne vulgaris, was localized in human skin. Spectrally resolved fluorescence images of bacteria distribution in the face were obtained by a slow-scan CCD camera combined with a tunable liquid crystal filter. The structured autofluorescence of dental caries and dental plaque in the red is caused by oral bacteria, like Bacteroides or Actinomyces odontolyticus. `Caries images' were created by time-gated imaging in the ns-region after ultrashort laser excitation. Time-gated measurements allow the suppression of backscattered light and non-porphyrin autofluorescence. Biopsies of oral squamous cell carcinoma exhibited red autofluorescence in necrotic regions and high concentrations of the porphyrin-producing bacterium Pseudomonas aerigunosa. These studies suggest that the temporal and spectral characteristics of bacterial autofluorescence can be used in the diagnosis and treatment of a variety of diseases.

  3. Green autofluorescence, a double edged monitoring tool for bacterial growth and activity in micro-plates

    Science.gov (United States)

    Mihalcescu, Irina; Van-Melle Gateau, Mathilde; Chelli, Bernard; Pinel, Corinne; Ravanat, Jean-Luc

    2015-12-01

    The intrinsic green autofluorescence of an Escherichia coli culture has long been overlooked and empirically corrected in green fluorescent protein (GFP) reporter experiments. We show here, by using complementary methods of fluorescence analysis and HPLC, that this autofluorescence, principally arise from the secreted flavins in the external media. The cells secrete roughly 10 times more than what they keep inside. We show next that the secreted flavin fluorescence can be used as a complementary method in measuring the cell concentration particularly when the classical method, based on optical density measure, starts to fail. We also demonstrate that the same external flavins limit the dynamical range of GFP quantification and can lead to a false interpretation of lower global dynamic range of expression than what really happens. In the end we evaluate different autofluorescence correction methods to extract the real GFP signal.

  4. Use of narrow-band imaging bronchoscopy in detection of lung cancer.

    Science.gov (United States)

    Zaric, Bojan; Perin, Branislav

    2010-05-01

    Narrow-band imaging (NBI) is a new endoscopic technique designed for detection of pathologically altered submucosal and mucosal microvascular patterns. The combination of magnification videobronchoscopy and NBI showed great potential in the detection of precancerous and cancerous lesions of the bronchial mucosa. The preliminary studies confirmed supremacy of NBI over white-light videobronchoscopy in the detection of premalignant and malignant lesions. Pathological patterns of capillaries in bronchial mucosa are known as Shibuya's descriptors (dotted, tortuous and abrupt-ending blood vessels). Where respiratory endoscopy is concerned, the NBI is still a 'technology in search of proper indication'. More randomized trials are necessary to confirm the place of NBI in the diagnostic algorithm, and more trials are needed to evaluate the relation of NBI to autofluorescence videobronchoscopy and to white-light magnification videobronchoscopy. Considering the fact that NBI examination of the tracheo-bronchial tree is easy, reproducible and clear to interpret, it is certain that NBI videobronchoscopy will play a significant role in the future of lung cancer detection and staging.

  5. Automatic real-time detection of endoscopic procedures using temporal features.

    Science.gov (United States)

    Stanek, Sean R; Tavanapong, Wallapak; Wong, Johnny; Oh, Jung Hwan; de Groen, Piet C

    2012-11-01

    Endoscopy is used for inspection of the inner surface of organs such as the colon. During endoscopic inspection of the colon or colonoscopy, a tiny video camera generates a video signal, which is displayed on a monitor for interpretation in real-time by physicians. In practice, these images are not typically captured, which may be attributed by lack of fully automated tools for capturing, analysis of important contents, and quick and easy retrieval of these contents. This paper presents the description and evaluation results of our novel software that uses new metrics based on image color and motion over time to automatically record all images of an individual endoscopic procedure into a single digitized video file. The software automatically discards out-patient video frames between different endoscopic procedures. We validated our software system on 2464 h of live video (over 265 million frames) from endoscopy units where colonoscopy and upper endoscopy were performed. Our previous classification method achieved a frame-based sensitivity of 100.00%, but only a specificity of 89.22%. Our new method achieved a frame-based sensitivity and specificity of 99.90% and 99.97%, a significant improvement. Our system is robust for day-to-day use in medical practice. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  6. Endoscopic retrograde cholanglopancreatography

    International Nuclear Information System (INIS)

    Horii, S.C.; Garra, B.S.; Zeman, R.K.; Krasner, B.H.; Lo, S.C.B.; Davros, W.J.; Silverman, P.M.; Cattau, E.L.; Fleischer, D.E.; Benjamin, S.B.S.B.

    1989-01-01

    As part of the clinical evaluation of image management and communications system (IMACS), the authors undertook a prospective study to compare conventional film versus digitized film viewed on a workstation. Twenty-five each of normal and abnormal endoscopic retrograde cholangiopancreatographic (ERCP) studies were digitized with a 1,684 x 2,048-pixel matrix and evaluated in a single-blind fashion on the workstation. The resulting interpretations were then compared with those resulting from interpretation of film (spot film and 100-mm photospot) images. They report that no significant differences were found in ability to see anatomic detail or pathology. A second study involved performing 10 ERCP studies in a lithotripsy suite equipped with biplane digital fluoroscopy. The digital video displays were comparable in quality to that of film. Progress is being made in using the IMACS for archiving and retrieval of all current ERCP images

  7. Interactive navigation-guided ophthalmic plastic surgery: navigation enabling of telescopes and their use in endoscopic lacrimal surgeries

    Directory of Open Access Journals (Sweden)

    Ali MJ

    2016-11-01

    Full Text Available Mohammad Javed Ali,1 Swati Singh,1 Milind N Naik,1 Swathi Kaliki,2 Tarjani Vivek Dave1 1The Institute of Dacryology, 2The Operation Eyesight Universal Institute for Eye Cancer, L.V. Prasad Eye Institute, Hyderabad, India Purpose: The aims of this study were to report the preliminary experience of using telescopes, which were enabled for navigation guidance, and their utility in complex endoscopic lacrimal surgeries. Methods: Navigation enabling of the telescope was achieved by using the AxiEM™ malleable neuronavigation shunt stylet. Image-guided dacryolocalization was performed in five patients using the intraoperative image-guided StealthStation™ system in the electromagnetic mode. The “look ahead” protocol software was used to assist the surgeon in assessing the intraoperative geometric location of the endoscope and what lies ahead in real time. All patients underwent navigation-guided powered endoscopic dacryocystorhinostomy. The utility of uninterrupted navigation guidance throughout the surgery with the endoscope as the navigating tool was noted. Results: Intraoperative geometric localization of the lacrimal sac and the nasolacrimal duct could be easily deciphered. Constant orientation of the lacrimal drainage system and the peri-lacrimal anatomy was possible without the need for repeated point localizations throughout the surgery. The “look ahead” features could accurately alert the surgeon of anatomical structures that exists at 5, 10 and 15 mm in front of the endoscope. Good securing of the shunt stylet with the telescope was found to be essential for constant and accurate navigation. Conclusion: Navigation-enabled endoscopes provide the surgeon with the advantage of sustained stereotactic anatomical awareness at all times during the surgery. Keywords: telescope, endoscope, image guidance, navigation, lacrimal surgery, powered endoscopic DCR

  8. Multimodal Navigation in Endoscopic Transsphenoidal Resection of Pituitary Tumors Using Image-Based Vascular and Cranial Nerve Segmentation: A Prospective Validation Study.

    Science.gov (United States)

    Dolati, Parviz; Eichberg, Daniel; Golby, Alexandra; Zamani, Amir; Laws, Edward

    2016-11-01

    Transsphenoidal surgery (TSS) is the most common approach for the treatment of pituitary tumors. However, misdirection, vascular damage, intraoperative cerebrospinal fluid leakage, and optic nerve injuries are all well-known complications, and the risk of adverse events is more likely in less-experienced hands. This prospective study was conducted to validate the accuracy of image-based segmentation coupled with neuronavigation in localizing neurovascular structures during TSS. Twenty-five patients with a pituitary tumor underwent preoperative 3-T magnetic resonance imaging (MRI), and MRI images loaded into the navigation platform were used for segmentation and preoperative planning. After patient registration and subsequent surgical exposure, each segmented neural or vascular element was validated by manual placement of the navigation probe or Doppler probe on or as close as possible to the target. Preoperative segmentation of the internal carotid artery and cavernous sinus matched with the intraoperative endoscopic and micro-Doppler findings in all cases. Excellent correspondence between image-based segmentation and the endoscopic view was also evident at the surface of the tumor and at the tumor-normal gland interfaces. Image guidance assisted the surgeons in localizing the optic nerve and chiasm in 64% of cases. The mean accuracy of the measurements was 1.20 ± 0.21 mm. Image-based preoperative vascular and neural element segmentation, especially with 3-dimensional reconstruction, is highly informative preoperatively and potentially could assist less-experienced neurosurgeons in preventing vascular and neural injury during TSS. In addition, the accuracy found in this study is comparable to previously reported neuronavigation measurements. This preliminary study is encouraging for future prospective intraoperative validation with larger numbers of patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Sphincter of Oddi stenosis: diagnosis using hepatobiliary scintigraphy and endoscopic manometry

    International Nuclear Information System (INIS)

    Lee, R.G.L.; Gregg, J.A.; Koroshetz, A.M.; Hill, T.C.; Clouse, M.E.

    1985-01-01

    To determine the role of radionuclide imaging in diagnosing sphincter of Oddi stenosis, 21 patients with symptoms suggesting this disorder underwent endoscopic retrograde cholangiopancreatography, cholescintigraphy, and, when possible, endoscopic manometry. Those patients with abnormal hepatobiliary scintigraphy results had a mean basal sphincter pressure of 38.5 mm Hg. Sphincter pressures could not be measured in six patients with sphincters too tight to cannulate. Ten patients who underwent hepatobiliary scanning both before and after sphincter surgery had normal scan results of the repeat study. Hepatobiliary imaging appears useful for diagnosis of sphincter of Oddi stenosis in selected patients in whom manometry cannot be performed and for objective assessment of response to therapy

  10. Update on endoscopic pancreatic function testing

    Institute of Scientific and Technical Information of China (English)

    Tyler Stevens; Mansour A Parsi

    2011-01-01

    Hormone-stimulated pancreatic function tests (PFTs) are considered the gold standard for measuring pancreatic exocrine function. PFTs involve the administration of intravenous secretin or cholecystokinin, followed by collection and analysis of pancreatic secretions. Because exocrine function may decline in the earliest phase of pancreatic fibrosis, PFTs are considered accurate for diagnosing chronic pancreatitis. Unfortunately, these potentially valuable tests are infrequently performed except at specialized centers, because they are time consuming and complicated. To overcome these limitations, endoscopic PFT methods have been developed which include aspiration of pancreatic secretions through the suction channel of the endoscope. The secretin endoscopic pancreatic function test (ePFT) involves collection of duodenal aspirates at 15, 30, 45 and 60 min after secretin stimulation. A bicarbonate concentration greater than 80 mmol/L in any of the samples is considered a normal result. The secretin ePFT has demonstrated good sensitivity and specificity compared with various reference standards, including the "Dreiling tube" secretin PFT, endoscopic ultrasound, and surgical histology. Furthermore, a standard autoanalyzer can be used for bicarbonate analysis, which allows the secretin ePFT to be performed at any hospital. The secretin ePFT may complement imaging tests like endoscopic ultrasound (EUS) in the diagnosis of early chronic pancreatitis.This paper will review the literature validating the use of ePFT in the diagnosis of exocrine insufficiency and chronic pancreatitis. Newer developments will also be discussed, including the feasibility of combined EUS/ePFT, the use of cholecystokinin alone or in combination with secretin, and the discovery of new protein and lipid pancreatic juice biomarkers which may complement traditionalfluid analysis.

  11. Label-free in vivo in situ diagnostic imaging by cellular metabolism quantification with a flexible multiphoton endomicroscope (Conference Presentation)

    Science.gov (United States)

    Leclerc, Pierre; Hage, Charles-Henri; Fabert, Marc; Brevier, Julien; O'Connor, Rodney P.; Bardet-Coste, Sylvia M.; Habert, Rémi; Braud, Flavie; Kudlinski, Alexandre; Louradour, Frederic

    2017-02-01

    Multiphoton microscopy is a cutting edge imaging modality leading to increasing advances in biology and also in the clinical field. To use it at its full potential and at the very heart of clinical practice, there have been several developments of fiber-based multiphoton microendoscopes. The application for those probes is now limited by few major restrictions, such as the difficulty to collect autofluorescence signals from tissues and cells theses being inherently weak (e.g. the ones from intracellular NADH or FAD metabolites). This limitation reduces the usefulness of microendoscopy in general, effectively restraining it to morphological imaging modality requiring staining of the tissues. Our aim is to go beyond this limitation, showing for the first time label-free cellular metabolism monitoring, in vivo in situ in real time. The experimental setup is an upgrade of a recently published one (Ducourthial et.al, Scientific Reports, 2016) where femtosecond pulse fiber delivery is further optimized thank's to a new transmissive-GRISM-based pulse stretcher permitting high energy throughput and wide bandwidth. This device allows fast sequential operation with two different excitation wavelengths for efficient two-photon excited NADH and FAD autofluorescence endoscopic detection (i.e. 860 nm for FAD and 760 nm for NADH), enabling cellular optical redox ratio quantification at 8 frames/s. The obtained results on cell models in vitro and also on animal models in vivo (e.g. neurons of a living mouse) prove that we accurately assess the level of NADH and FAD at subcellular resolution through a 3-meters-long fiber with our miniaturized probe (O.D. =2.2 mm).

  12. ADAPTIVE OPTICS IMAGING OF FOVEAL SPARING IN GEOGRAPHIC ATROPHY SECONDARY TO AGE-RELATED MACULAR DEGENERATION.

    Science.gov (United States)

    Querques, Giuseppe; Kamami-Levy, Cynthia; Georges, Anouk; Pedinielli, Alexandre; Capuano, Vittorio; Blanco-Garavito, Rocio; Poulon, Fanny; Souied, Eric H

    2016-02-01

    To describe adaptive optics (AO) imaging of foveal sparing in geographic atrophy (GA) secondary to age-related macular degeneration. Flood-illumination AO infrared (IR) fundus images were obtained in four consecutive patients with GA using an AO retinal camera (rtx1; Imagine Eyes). Adaptive optics IR images were overlaid with confocal scanning laser ophthalmoscope near-IR autofluorescence images to allow direct correlation of en face AO features with areas of foveal sparing. Adaptive optics appearance of GA and foveal sparing, preservation of functional photoreceptors, and cone densities in areas of foveal sparing were investigated. In 5 eyes of 4 patients (all female; mean age 74.2 ± 11.9 years), a total of 5 images, sized 4° × 4°, of foveal sparing visualized on confocal scanning laser ophthalmoscope near-IR autofluorescence were investigated by AO imaging. En face AO images revealed GA as regions of inhomogeneous hyperreflectivity with irregularly dispersed hyporeflective clumps. By direct comparison with adjacent regions of GA, foveal sparing appeared as well-demarcated areas of reduced reflectivity with less hyporeflective clumps (mean 14.2 vs. 3.2; P = 0.03). Of note, in these areas, en face AO IR images revealed cone photoreceptors as hyperreflective dots over the background reflectivity (mean cone density 3,271 ± 1,109 cones per square millimeter). Microperimetry demonstrated residual function in areas of foveal sparing detected by confocal scanning laser ophthalmoscope near-IR autofluorescence. Adaptive optics allows the appreciation of differences in reflectivity between regions of GA and foveal sparing. Preservation of functional cone photoreceptors was demonstrated on en face AO IR images in areas of foveal sparing detected by confocal scanning laser ophthalmoscope near-IR autofluorescence.

  13. Tuberculosis and the pancreas: a diagnostic challenge solved by endoscopic ultrasound. A case series.

    Science.gov (United States)

    Chatterjee, Suvadip; Schmid, Matthias L; Anderson, Kirsty; Oppong, Kofi W

    2012-03-01

    Pancreatic tuberculosis is a rare disease. It can be easily confused with malignancy or pancreatitis on imaging. This could result in unnecessary surgery. As this is a treatable disease it is imperative to diagnose this condition pre-operatively. We report three cases of pancreatic tuberculosis that were diagnosed by endoscopic ultrasound. In conclusion, endoscopic ultrasound is the diagnostic modality of choice for pancreatic tuberculosis facilitating high resolution imaging, as well as sampling of tissue for staining, cytology, culture and polymerase chain reaction assay.

  14. Progress in Molecular Imaging in Endoscopy and Endomicroscopy for Cancer Imaging

    Directory of Open Access Journals (Sweden)

    Supang Khondee

    2013-01-01

    Full Text Available Imaging is an essential tool for effective cancer management. Endoscopes are important medical instruments for performing in vivo imaging in hollow organs. Early detection of cancer can be achieved with surveillance using endoscopy, and has been shown to reduce mortality and to improve outcomes. Recently, great advancements have been made in endoscopic instruments, including new developments in optical designs, light sources, optical fibers, miniature scanners, and multimodal systems, allowing for improved resolution, greater tissue penetration, and multispectral imaging. In addition, progress has been made in the development of highly-specific optical probes, allowing for improved specificity for molecular targets. Integration of these new endoscopic instruments with molecular probes provides a unique opportunity for significantly improving patient outcomes and has potential to further improve early detection, image guided therapy, targeted therapy, and personalized medicine. This work summarizes current and evolving endoscopic technologies, and provides an overview of various promising optical molecular probes.

  15. Modelling of a laser-pumped light source for endoscopic surgery

    Science.gov (United States)

    Nadeau, Valerie J.; Elson, Daniel S.; Hanna, George B.; Neil, Mark A. A.

    2008-09-01

    A white light source, based on illumination of a yellow phosphor with a fibre-coupled blue-violet diode laser, has been designed and built for use in endoscopic surgery. This narrow light probe can be integrated into a standard laparoscope or inserted into the patient separately via a needle. We present a Monte Carlo model of light scattering and phosphorescence within the phosphor/silicone matrix at the probe tip, and measurements of the colour, intensity, and uniformity of the illumination. Images obtained under illumination with this light source are also presented, demonstrating the improvement in illumination quality over existing endoscopic light sources. This new approach to endoscopic lighting has the advantages of compact design, improved ergonomics, and more uniform illumination in comparison with current technologies.

  16. Laser injury and in vivo multimodal imaging using a mouse model

    Science.gov (United States)

    Pocock, Ginger M.; Boretsky, Adam; Gupta, Praveena; Oliver, Jeff W.; Motamedi, Massoud

    2011-03-01

    Balb/c wild type mice were used to perform in vivo experiments of laser-induced thermal damage to the retina. A Heidelberg Spectralis HRA confocal scanning laser ophthalmoscope with a spectral domain optical coherence tomographer was used to obtain fundus and cross-sectional images of laser induced injury in the retina. Sub-threshold, threshold, and supra-threshold lesions were observed using optical coherence tomography (OCT), infrared reflectance, red-free reflectance, fluorescence angiography, and autofluorescence imaging modalities at different time points post-exposure. Lesions observed using all imaging modalities, except autofluorescence, were not visible immediately after exposure but did resolve within an hour and grew in size over a 24 hour period. There was a decrease in fundus autofluorescence at exposure sites immediately following exposure that developed into hyper-fluorescence 24-48 hours later. OCT images revealed threshold damage that was localized to the RPE but extended into the neural retina over a 24 hour period. Volumetric representations of the mouse retina were created to visualize the extent of damage within the retina over a 24 hour period. Multimodal imaging provides complementary information regarding damage mechanisms that may be used to quantify the extent of the damage as well as the effectiveness of treatments without need for histology.

  17. Liver parenchumography following endoscopic retrograde cholangiopancreatography (ERCP)

    International Nuclear Information System (INIS)

    Revert, A.; Arana, E.; Pertejo, V.; Berenguer, M.; Masip, M.J.

    1998-01-01

    Focal liver opacification during endoscopic retrograde cholangiography (ERCP) is an uncommon complication caused by excessive pressure during contrast injection. In this situation, ERCP must be interrupted and the position of the cannula checked. We recommend that these images be excluded from the diagnosis of tumor or cystic cavities. 4 refs

  18. Ultrathin endoscopes based on multicore fibers and adaptive optics: a status review and perspectives.

    Science.gov (United States)

    Andresen, Esben Ravn; Sivankutty, Siddharth; Tsvirkun, Viktor; Bouwmans, Géraud; Rigneault, Hervé

    2016-12-01

    We take stock of the progress that has been made into developing ultrathin endoscopes assisted by wave front shaping. We focus our review on multicore fiber-based lensless endoscopes intended for multiphoton imaging applications. We put the work into perspective by comparing with alternative approaches and by outlining the challenges that lie ahead.

  19. Tissue Discrimination by Uncorrected Autofluorescence Spectra: A Proof-of-Principle Study for Tissue-Specific Laser Surgery

    Directory of Open Access Journals (Sweden)

    Katja Tangermann-Gerk

    2013-10-01

    Full Text Available Laser surgery provides a number of advantages over conventional surgery. However, it implies large risks for sensitive tissue structures due to its characteristic non-tissue-specific ablation. The present study investigates the discrimination of nine different ex vivo tissue types by using uncorrected (raw autofluorescence spectra for the development of a remote feedback control system for tissue-selective laser surgery. Autofluorescence spectra (excitation wavelength 377 ± 50 nm were measured from nine different ex vivo tissue types, obtained from 15 domestic pig cadavers. For data analysis, a wavelength range between 450 nm and 650 nm was investigated. Principal Component Analysis (PCA and Quadratic Discriminant Analysis (QDA were used to discriminate the tissue types. ROC analysis showed that PCA, followed by QDA, could differentiate all investigated tissue types with AUC results between 1.00 and 0.97. Sensitivity reached values between 93% and 100% and specificity values between 94% and 100%. This ex vivo study shows a high differentiation potential for physiological tissue types when performing autofluorescence spectroscopy followed by PCA and QDA. The uncorrected autofluorescence spectra are suitable for reliable tissue discrimination and have a high potential to meet the challenges necessary for an optical feedback system for tissue-specific laser surgery.

  20. Transforaminal Percutaneous Endoscopic Discectomy and Foraminoplasty after Lumbar Spinal Fusion Surgery.

    Science.gov (United States)

    Wu, Jian-Jun; Chen, Hui-Zhen; Zheng, Changkun

    2017-07-01

    The most common causes of pain following lumbar spinal fusions are residual herniation, or foraminal fibrosis and foraminal stenosis that is ignored, untreated, or undertreated. The original surgeon may advise his patient that nothing more can be done in his opinion that the nerve was visually decompressed by the original surgery. Post-operative imaging or electrophysiological assessment may be inadequate to explain all the reasons for residual or recurrent symptoms. Treatment of failed lumbar spinal fusions by repeat traditional open revision surgery usually incorporates more extensive decompression causing increased instability and back pain. The authors, having limited their practice to endoscopic surgery over the last 10 years, report on their experience gained during that period to relieve pain by transforaminal percutaneous endoscopic revision of lumbar spinal fusions. To assess the effectiveness of transforaminal percutaneous endoscopic discectomy and foraminoplasty in patients with pain after lumbar spinal fusion. Retrospective study. Inpatient surgery center. Sixteen consecutive patients with pain after lumbar spinal fusions presenting with back and leg pain that had supporting imaging diagnosis of foraminal stenosis and/or residual/recurrent disc herniation, or whose pain complaint was supported by relief from diagnostic and therapeutic injections, were offered percutaneous transforaminal endoscopic discectomy and foraminoplasty over a repeat open procedure. Each patient sought consultation following a transient successful, partially successful or unsuccessful open lumbar spinal fusions treatment for disc herniation or spinal stenosis. Endoscopic foraminoplasty was also performed to either decompress the bony foramen in the case of foraminal stenosis, or to allow for endoscopic visual examination of the affected traversing and exiting nerve roots in the axilla. The average follow-up time was 30.3 months, minimum 12 months. Outcome data at each visit

  1. Location of disease on imaging may predict radiation exposure during endoscopic retrograde cholangiopancreatography

    International Nuclear Information System (INIS)

    Choi, Moon Hyung; Jung, Seung Eun; Yoon, Seung Bae; Lee, In Seokand; Byun, Jae Young

    2017-01-01

    Endoscopic retrograde cholangiopancreatography (ERCP) is performed for various diseases. The aim of this study is to evaluate the difference of dose-area product (DAP) during the ERCP procedures according to location of the lesion. We performed a retrospective study of consecutive 217 therapeutic ERCP examinations performed between November 2014 and April 2015 at a tertiary care center. ERCP procedures divided into two groups according to location of the lesion identified on imaging: lesions in the common hepatic duct (CHD) or the common bile duct (CBD) and lesions in the hepatic hilum or the intrahepatic duct (IHD). The mean DAP of the hilum-IHD group (48.7 Gy cm 2 ) was significantly higher than that of the CBD-CHD group (34.9 Gy cm 2 ) (P = 0.003). Radiation exposure during ERCP was significantly different according to location of bile duct lesion. (authors)

  2. Multispectral open-air intraoperative fluorescence imaging.

    Science.gov (United States)

    Behrooz, Ali; Waterman, Peter; Vasquez, Kristine O; Meganck, Jeff; Peterson, Jeffrey D; Faqir, Ilias; Kempner, Joshua

    2017-08-01

    Intraoperative fluorescence imaging informs decisions regarding surgical margins by detecting and localizing signals from fluorescent reporters, labeling targets such as malignant tissues. This guidance reduces the likelihood of undetected malignant tissue remaining after resection, eliminating the need for additional treatment or surgery. The primary challenges in performing open-air intraoperative fluorescence imaging come from the weak intensity of the fluorescence signal in the presence of strong surgical and ambient illumination, and the auto-fluorescence of non-target components, such as tissue, especially in the visible spectral window (400-650 nm). In this work, a multispectral open-air fluorescence imaging system is presented for translational image-guided intraoperative applications, which overcomes these challenges. The system is capable of imaging weak fluorescence signals with nanomolar sensitivity in the presence of surgical illumination. This is done using synchronized fluorescence excitation and image acquisition with real-time background subtraction. Additionally, the system uses a liquid crystal tunable filter for acquisition of multispectral images that are used to spectrally unmix target fluorescence from non-target auto-fluorescence. Results are validated by preclinical studies on murine models and translational canine oncology models.

  3. The Influence of Volume and Anatomic Location of Optic Disc Drusen on the Sensitivity of Autofluorescence

    DEFF Research Database (Denmark)

    Loft, Frederik Cornelius; Malmqvist, Lasse; Lindberg, Anne-Sofie Wessel

    2018-01-01

    Optic disc drusen (ODD) are acellular deposits in the optic nerve head. ODD can be diagnosed using different imaging modalities, including enhanced depth imaging optical coherence tomography (EDI-OCT) and autofluorescence (AF). It is unknown which factors determine the sensitivity of AF. The aim...... of this study was to investigate the effect of volume and anatomic location of ODD on the sensitivity of AF. Cross-sectional study. A total of 38 patients (75 eyes) with ODD were included. In 12 of 75 eyes (16%) and in 11 of 38 patients (29%), EDI-OCT detected ODD that were not detected by AF. In 24 distinctly...... solitary ODD, both increase in ODD volume (P = 0.0388) and a more superficial ODD location (P EDI-OCT is superior to AF in the diagnosis of ODD. Volume and anatomic location of ODD have a significant impact...

  4. Video-based measurements for wireless capsule endoscope tracking

    International Nuclear Information System (INIS)

    Spyrou, Evaggelos; Iakovidis, Dimitris K

    2014-01-01

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions. (paper)

  5. Video-based measurements for wireless capsule endoscope tracking

    Science.gov (United States)

    Spyrou, Evaggelos; Iakovidis, Dimitris K.

    2014-01-01

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions.

  6. Label-free imaging immune cells and collagen in atherosclerosis with two-photon and second harmonic generation microscopy

    Directory of Open Access Journals (Sweden)

    Chunqiang Li

    2016-01-01

    Full Text Available Atherosclerosis has been recognized as a chronic inflammation disease, in which many types of cells participate in this process, including lymphocytes, macrophages, dendritic cells (DCs, mast cells, vascular smooth muscle cells (SMCs. Developments in imaging technology provide the capability to observe cellular and tissue components and their interactions. The knowledge of the functions of immune cells and their interactions with other cell and tissue components will facilitate our discovery of biomarkers in atherosclerosis and prediction of the risk factor of rupture-prone plaques. Nonlinear optical microscopy based on two-photon excited autofluorescence and second harmonic generation (SHG were developed to image mast cells, SMCs and collagen in plaque ex vivo using endogenous optical signals. Mast cells were imaged with two-photon tryptophan autofluorescence, SMCs were imaged with two-photon NADH autofluorescence, and collagen were imaged with SHG. This development paves the way for further study of mast cell degranulation, and the effects of mast cell derived mediators such as induced synthesis and activation of matrix metalloproteinases (MMPs which participate in the degradation of collagen.

  7. Epigastric hernia contiguous with the laparoscopic port site after endoscopic robotic total prostatectomy.

    Science.gov (United States)

    Moriwaki, Yoshihiro; Otani, Jun; Okuda, Junzo; Maemoto, Ryo

    2018-03-23

    Both laparoscopic and endoscopic robotic surgery are widely accepted for many abdominal surgeries. However, the port site for the laparoscope cannot be easily sutured without defect, particularly in the cranial end; this can result in a port-site incisional hernia and trigger the progressive thinning and stretching of the linea alba, leading to epigastric hernia. In the present case, we encountered an epigastric hernia contiguous with an incisional scar at the port site from a previous endoscopic robotic total prostatectomy. Abdominal ultrasound and CT revealed that the width of the linea alba was 30-48 mm. Previous CT images prepared before endoscopic robotic prostatectomy had shown a thinning of the linea alba. We should be aware of the possibility of epigastric hernia after laparoscopic and endoscopic robotic surgery. In laparoscopic and endoscopic robotic surgery for a high-risk patient for epigastric hernia, we should consider additional sutures cranial to the port-site incision to prevent of an epigastric hernia. © 2018 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  8. A hands-free region-of-interest selection interface for solo surgery with a wide-angle endoscope: preclinical proof of concept.

    Science.gov (United States)

    Jung, Kyunghwa; Choi, Hyunseok; Hong, Hanpyo; Adikrishna, Arnold; Jeon, In-Ho; Hong, Jaesung

    2017-02-01

    A hands-free region-of-interest (ROI) selection interface is proposed for solo surgery using a wide-angle endoscope. A wide-angle endoscope provides images with a larger field of view than a conventional endoscope. With an appropriate selection interface for a ROI, surgeons can also obtain a detailed local view as if they moved a conventional endoscope in a specific position and direction. To manipulate the endoscope without releasing the surgical instrument in hand, a mini-camera is attached to the instrument, and the images taken by the attached camera are analyzed. When a surgeon moves the instrument, the instrument orientation is calculated by an image processing. Surgeons can select the ROI with this instrument movement after switching from 'task mode' to 'selection mode.' The accelerated KAZE algorithm is used to track the features of the camera images once the instrument is moved. Both the wide-angle and detailed local views are displayed simultaneously, and a surgeon can move the local view area by moving the mini-camera attached to the surgical instrument. Local view selection for a solo surgery was performed without releasing the instrument. The accuracy of camera pose estimation was not significantly different between camera resolutions, but it was significantly different between background camera images with different numbers of features (P solo surgeries without a camera assistant.

  9. Out-of-plane displacement measurement by means of endoscopic moire interferometry

    International Nuclear Information System (INIS)

    Martinez-Celorio, R.A.; Dirckx, Joris J.J.; Marti-Lopez, Luis; Pena-Lecona, Francisco G.

    2004-01-01

    An endoscopic moire technique is proposed for measuring out-of-plane displacements in difficult to reach places. The Ronchi grid is projected onto the tilted object with one endoscope with a 0 deg. viewing angle. The object with the projected grid is imaged by a second endoscope with a 30 deg. viewing angle onto a charge-coupled device. The captured images are stored in a PC, and are used to calculate the out-of-plane displacement of the object with a phase stepping technique. A computer generated grating method is used instead of a physical phase-shift device in the optical setup. This allows designing a set of three reference grids with profiles closely similar to the projected grating. The technique is robust against problems associated with the temporal shifting method, such as nonlinear phase shift and noise. To test the feasibility of the technique the measurement of out-of-plane displacements of about 35 μm of a latex membrane under deformation is demonstrated. The advantages and disadvantages are discussed

  10. Automated image alignment and segmentation to follow progression of geographic atrophy in age-related macular degeneration.

    Science.gov (United States)

    Ramsey, David J; Sunness, Janet S; Malviya, Poorva; Applegate, Carol; Hager, Gregory D; Handa, James T

    2014-07-01

    To develop a computer-based image segmentation method for standardizing the quantification of geographic atrophy (GA). The authors present an automated image segmentation method based on the fuzzy c-means clustering algorithm for the detection of GA lesions. The method is evaluated by comparing computerized segmentation against outlines of GA drawn by an expert grader for a longitudinal series of fundus autofluorescence images with paired 30° color fundus photographs for 10 patients. The automated segmentation method showed excellent agreement with an expert grader for fundus autofluorescence images, achieving a performance level of 94 ± 5% sensitivity and 98 ± 2% specificity on a per-pixel basis for the detection of GA area, but performed less well on color fundus photographs with a sensitivity of 47 ± 26% and specificity of 98 ± 2%. The segmentation algorithm identified 75 ± 16% of the GA border correctly in fundus autofluorescence images compared with just 42 ± 25% for color fundus photographs. The results of this study demonstrate a promising computerized segmentation method that may enhance the reproducibility of GA measurement and provide an objective strategy to assist an expert in the grading of images.

  11. Imaging rat esophagus using combination of reflectance confocal and multiphoton microscopy

    International Nuclear Information System (INIS)

    Zhuo, S M; Chen, J X; Jiang, X S; Lu, K C; Xie, S S

    2008-01-01

    We combine reflectance confocal microscopy (RCM) with multiphoton microscopy (MPM) to image rat esophagus. The two imaging modalities allow detection of layered–resolved complementary information from esophagus. In the keratinizing layer, the keratinocytes boundaries can be characterized by RCM, while the keratinocytes cytoplasm (keratin) can be further imaged by multiphoton autofluorescence signal. In the epithelium, the epithelial cellular boundaries and nucleus can be detected by RCM, and MPM can be used for imaging epithelial cell cytoplasm and monitoring metabolic state of epithelium. In the stroma, multiphoton autofluorescence signal is used to image elastin and second harmonic generation signal is utilized to detect collagen, while RCM is used to determine the optical property of stroma. Overall, these results suggest that the combination of RCM and MPM has potential to provide more important and comprehensive information for early diagnosis of esophageal cancer

  12. Sonographic and Endoscopic Findings in Cocaine-Induced Ischemic Colitis

    DEFF Research Database (Denmark)

    Leth, Thomas; Wilkens, Rune; Bonderup, Ole Kristian

    2015-01-01

    Cocaine-induced ischemic colitis is a recognized entity. The diagnosis is based on clinical and endoscopic findings. However, diagnostic imaging is helpful in the evaluation of abdominal symptoms and prior studies have suggested specific sonographic findings in ischemic colitis. We report...

  13. Skin autofluorescence and risk of micro- and macrovascular complications in patients with Type 2 diabetes mellitus-a multi-centre study

    NARCIS (Netherlands)

    Noordzij, M J; Mulder, D.J.; Oomen, P H N; Brouwer, T; Jager, J; Castro Cabezas, M; Lefrandt, J D; Smit, Andries

    2012-01-01

    AIMS: Skin autofluorescence is a non-invasive marker of advanced glycation end product accumulation. In a previous study, skin autofluorescence correlated with and predicted micro- and macrovascular complications in Type 2 diabetes in a primary care setting. The present cross-sectional study aims to

  14. Use of fluorescence spectroscopy to measure molecular autofluorescence in diabetic subjects

    International Nuclear Information System (INIS)

    Gomes, Cinthia Zanini

    2011-01-01

    Diabetes Mellitus (DM) comprises a complex metabolic syndrome, caused by reduced or absent secretion of insulin by pancreatic beta cells, leading to hyperglycemia. Hyperglycemia promotes glycation of proteins and, consequently, the appearance of advanced glycation end products (AGEs). Currently, diabetic patients are monitored by determining levels of glucose and glycated hemoglobin (HbA1c). The complications caused by hyperglycemia may be divided into micro and macrovascular complications, represented by retinopathy, nephropathy, neuropathy and cardiovascular disease. Albumin (HSA) is the most abundant serum protein in the human body and is subject to glycation. The Protoporphyrin IX (PpIX) is the precursor molecule of heme synthesis, structural component of hemoglobin. The in vitro and animals studies have indicated that hyperglycemia promotes a decrease in its concentration in erythrocytes. The fluorescence spectroscopy is a technique widely used in biomedical field. The autofluorescence corresponds to the intrinsic fluorescence present in some molecules, this being associated with the same structure. The aim of this study was to use fluorescence spectroscopy to measure levels of erythrocyte PpIX autofluorescence and AGE-HSA in diabetic and healthy subjects and compare them with levels of blood glucose and HbA1c. This study was conducted with 151 subjects (58 controls and 93 diabetics). Epidemiological data of patients and controls were obtained from medical records. For control subjects, blood glucose levels were obtained from medical records and levels of Hb1Ac obtained by using commercial kits. The determination of the PpIX autofluorescence was performed with excitation at 405 nm and emission at 632 nm. Determination of AGE-HSA was performed with excitation at 370 nm and emission at 455 nm. Approximately 50% of diabetic had micro and macrovascular lesions resulting from hyperglycemia. There were no significant differences in the PpIX emission intensity values

  15. Interpretations of Fundus Autofluorescence from Studies of the Bisretinoids of the Retina

    OpenAIRE

    Sparrow, Janet R.; Yoon, Kee Dong; Wu, Yalin; Yamamoto, Kazunori

    2010-01-01

    Elevated fundus autofluorescence signals can reflect enhanced lipofuscin in RPE cells, augmented fluorescence due to photooxidation, and/or excess bisretinoid fluorophores in photoreceptor cells due to mishandling of vitamin A aldehyde by dysfunctional cells.

  16. Successful Gastric Volvulus Reduction and Gastropexy Using a Dual Endoscope Technique

    Directory of Open Access Journals (Sweden)

    Laith H. Jamil

    2014-01-01

    Full Text Available Gastric volvulus is a life threatening condition characterized by an abnormal rotation of the stomach around an axis. Although the first line treatment of this disorder is surgical, we report here a case of gastric volvulus that was endoscopically managed using a novel strategy. An 83-year-old female with a history of pancreatic cancer status postpylorus-preserving Whipple procedure presented with a cecal volvulus requiring right hemicolectomy. Postoperative imaging included a CT scan and upper GI series that showed a gastric volvulus with the antrum located above the diaphragm. An upper endoscopy was advanced through the pylorus into the duodenum and left in this position to keep the stomach under the diaphragm. A second pediatric endoscope was advanced alongside and used to complete percutaneous endoscopic gastrostomy (PEG placement for anterior gastropexy. The patient’s volvulus resolved and there were no complications. From our review of the literature, the dual endoscopic technique employed here has not been previously described. Patients who are poor surgical candidates or those who do not require emergent surgery can possibly benefit the most from similar minimally invasive endoscopic procedures as described here.

  17. No need for labels: the autofluorescence of Leishmania tarentolae mitochondria and the necessity of negative controls.

    Directory of Open Access Journals (Sweden)

    Elisabeth Eckers

    Full Text Available BACKGROUND: Fluorescence microscopy is a powerful tool to study the morphology and function of subcellular compartments or to determine the localization of proteins. The method is also regularly used for the analysis of parasitic protists including kinetoplastida. RESULTS: Here, we report a significant autofluorescence of Leishmania tarentolae mitochondria. The autofluorescence, presumably caused by flavoproteins, was detectable using a variety of cell fixation protocols and had a maximum emission at approximately 538 nm. Stable signals were obtained with xenon lamps as a light source and filter sets that are commonly used for the detection of green fluorescent protein. CONCLUSIONS: On the one hand, we present a methodological approach to examine mitochondrial morphology or to study the colocalization of mitochondrial proteins without additional staining or labeling procedures. On the other hand, under certain experimental conditions, mitochondrial autofluorescence can result in false positive signals, demonstrating the necessity to analyze unlabeled cells as negative controls.

  18. Virtual endoscopy combined with intraoperative neuronavigation for planning of endoscopic surgery in patients with occlusive hydrocephalus and intracranial cysts

    International Nuclear Information System (INIS)

    Krombach, G.A.; Haage, P.; Kilbinger, M.; Rohde, V.; Struffert, T.; Thron, A.

    2002-01-01

    We assessed the clinical value of MR ventriculoscopy (virtual endoscopy, VE) combined with image-guided frameless stereotaxy for endoscopic surgery of occlusive hydrocephalus and intracranial cysts. VE was obtained in 20 patients with hydrocephalus and three with intracranial cysts. All surgical operations were endoscopic. The path of the rigid endoscope to the target point was planned using neuronavigation. VE was carried out along the same trajectory retrospectively in 20 cases and prospectively in three. The results were analysed for demonstration of anatomical landmarks and structures at risk. VE was successful in all patients. Possible obstacles to endoscopic access to the lamina terminalis and the basal cisterns and structures at risk, such as the basilar artery, were clearly shown in relation to the direction of the endoscope. However, the floor of the third ventricle and septum pellucidum were not clearly seen and possible abnormalities could therefore not be appreciated. VE can provide realistic simulation of endoscopic third ventriculostomy and cystostomy. The appropriate trepanation point and trajectory of the endoscope can be assessed with regard to the size of the foramen of Monro and the position of vulnerable structures. This simulated trajectory can be adapted to the field of operation by image-guided neuronavigation. This regime may potentially reduce the risk of damage to intracranial structures. (orig.)

  19. Current Innovations in Endoscopic Therapy for the Management of Colorectal Cancer: From Endoscopic Submucosal Dissection to Endoscopic Full-Thickness Resection

    Directory of Open Access Journals (Sweden)

    Shintaro Fujihara

    2014-01-01

    Full Text Available Endoscopic submucosal dissection (ESD is accepted as a minimally invasive treatment for colorectal cancer. However, due to technical difficulties and an increased rate of complications, ESD is not widely used in the colorectum. In some cases, endoscopic treatment alone is insufficient for disease control, and laparoscopic surgery is required. The combination of laparoscopic surgery and endoscopic resection represents a new frontier in cancer treatment. Recent developments in advanced polypectomy and minimally invasive surgical techniques will enable surgeons and endoscopists to challenge current practice in colorectal cancer treatment. Endoscopic full-thickness resection (EFTR of the colon offers the potential to decrease the postoperative morbidity and mortality associated with segmental colectomy while enhancing the diagnostic yield compared to current endoscopic techniques. However, closure is necessary after EFTR and natural transluminal endoscopic surgery (NOTES. Innovative methods and new devices for EFTR and suturing are being developed and may potentially change traditional paradigms to achieve minimally invasive surgery for colorectal cancer. The present paper aims to discuss the complementary role of ESD and the future development of EFTR. We focus on the possibility of achieving EFTR using the ESD method and closing devices.

  20. Experimental transapical endoscopic ventricular visualization and mitral repair.

    Science.gov (United States)

    Ruttkay, Tamas; Czesla, Markus; Nagy, Henrietta; Götte, Julia; Baksa, Gabor; Patonay, Lajos; Doll, Nicolas; Galajda, Zoltan

    2015-04-01

    An increasing number of experimental beating heart animal studies describe simple transapical mitral valve repairs based on the direct endoscopic visualization of the left ventricle. The aim of our human cadaveric study was to develop a method for more complex transapical endoscopic procedures by on-pump heart operations. After preparation of 20 human fresh cadavers, a standard left anterolateral minithoracotomy was performed in the fifth intercostal space and the pericardium was entered. A rigid 0 degree endoscope and the instruments were introduced through a silicon apical port. To restore the natural form of the left heart, CO2 was insufflated. To test the mitral valve competence, the left ventricle was pressure-injected with saline after each step. After transecting the chords of the A2 segment of the anterior mitral leaflet before the experimental mitral valve repair, the tendinous chord was replaced using an especially designed clip chord. The second part of the experiment consisted of a segmental excision of the P2 segment of the posterior mitral leaflet followed by a standard valvuloplasty and suture annuloplasty. With the help of the described transapical endoscopic mitral valve repair technique, we gained direct visual information of the coaptation line of the mitral leaflets as well as the anatomy and function of the subvalvular apparatus. Using intracardiac imaging, we could perform successful transapical complex mitral repair in each case. The minimally invasive transapical endoscopic method has the potential to offer advantages for on-pump mitral valve repair procedures even in complex mitral valve repair cases. Georg Thieme Verlag KG Stuttgart · New York.

  1. An Innovate Robotic Endoscope Guidance System for Transnasal Sinus and Skull Base Surgery: Proof of Concept.

    Science.gov (United States)

    Friedrich, D T; Sommer, F; Scheithauer, M O; Greve, J; Hoffmann, T K; Schuler, P J

    2017-12-01

    Objective  Advanced transnasal sinus and skull base surgery remains a challenging discipline for head and neck surgeons. Restricted access and space for instrumentation can impede advanced interventions. Thus, we present the combination of an innovative robotic endoscope guidance system and a specific endoscope with adjustable viewing angle to facilitate transnasal surgery in a human cadaver model. Materials and Methods  The applicability of the robotic endoscope guidance system with custom foot pedal controller was tested for advanced transnasal surgery on a fresh frozen human cadaver head. Visualization was enabled using a commercially available endoscope with adjustable viewing angle (15-90 degrees). Results  Visualization and instrumentation of all paranasal sinuses, including the anterior and middle skull base, were feasible with the presented setup. Controlling the robotic endoscope guidance system was effectively precise, and the adjustable endoscope lens extended the view in the surgical field without the common change of fixed viewing angle endoscopes. Conclusion  The combination of a robotic endoscope guidance system and an advanced endoscope with adjustable viewing angle enables bimanual surgery in transnasal interventions of the paranasal sinuses and the anterior skull base in a human cadaver model. The adjustable lens allows for the abandonment of fixed-angle endoscopes, saving time and resources, without reducing the quality of imaging.

  2. High Resolution Sub-MM Fiberoptic Endoscope Final Report CRADA No. TSB-1447-97

    Energy Technology Data Exchange (ETDEWEB)

    Stone, Gary F. [Univ. of California, Livermore, CA (United States); Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Smith, John [CML Fiberoptics, Inc., Auburn, NY (United States)

    2018-01-22

    At the time of the CRADA, LLNL needed to develop a sub-mm outer diameter fiberoptic endoscope with 25pm or better resolution at 3-lOmm working distance to support the Enhanced Surveillance Program (ESP) and the Core Surveillance Program for DOE. The commercially available systems did not meet the image resolution requirements and development work was needed to reach three goals. We also needed to perform preliminary investigations into the production of such an endoscope with a steerable-articulated distal end. The goal of such an endoscope was to allow for a 45 degree inspection cone including the lens field of view.

  3. Endoscopic third ventriculostomy

    Directory of Open Access Journals (Sweden)

    Yad Ram Yadav

    2012-01-01

    Full Text Available Endoscopic third ventriculostomy (ETV is considered as a treatment of choice for obstructive hydrocephalus. It is indicated in hydrocephalus secondary to congenital aqueductal stenosis, posterior third ventricle tumor, cerebellar infarct, Dandy-Walker malformation, vein of Galen aneurism, syringomyelia with or without Chiari malformation type I, intraventricular hematoma, post infective, normal pressure hydrocephalus, myelomeningocele, multiloculated hydrocephalus, encephalocele, posterior fossa tumor and craniosynostosis. It is also indicated in block shunt or slit ventricle syndrome. Proper Pre-operative imaging for detailed assessment of the posterior communicating arteries distance from mid line, presence or absence of Liliequist membrane or other membranes, located in the prepontine cistern is useful. Measurement of lumbar elastance and resistance can predict patency of cranial subarachnoid space and complex hydrocephalus, which decides an ultimate outcome. Water jet dissection is an effective technique of ETV in thick floor. Ultrasonic contact probe can be useful in selected patients. Intra-operative ventriculo-stomography could help in confirming the adequacy of endoscopic procedure, thereby facilitating the need for shunt. Intraoperative observations of the patent aqueduct and prepontine cistern scarring are predictors of the risk of ETV failure. Such patients may be considered for shunt surgery. Magnetic resonance ventriculography and cine phase contrast magnetic resonance imaging are effective in assessing subarachnoid space and stoma patency after ETV. Proper case selection, post-operative care including monitoring of ICP and need for external ventricular drain, repeated lumbar puncture and CSF drainage, Ommaya reservoir in selected patients could help to increase success rate and reduce complications. Most of the complications develop in an early post-operative, but fatal complications can develop late which indicate an importance of

  4. Combining endoscopic ultrasound with Time-Of-Flight PET: The EndoTOFPET-US Project

    CERN Document Server

    Frisch, Benjamin

    2013-01-01

    The EndoTOFPET-US collaboration develops a multimodal imaging technique for endoscopic exams of the pancreas or the prostate. It combines the benefits of high resolution metabolic imaging with Time-Of-Flight Positron Emission Tomography (TOF PET) and anatomical imaging with ultrasound (US). EndoTOFPET-US consists of a PET head extension for a commercial US endoscope and a PET plate outside the body in coincidence with the head. The high level of miniaturization and integration creates challenges in fields such as scintillating crystals, ultra-fast photo-detection, highly integrated electronics, system integration and image reconstruction. Amongst the developments, fast scintillators as well as fast and compact digital SiPMs with single SPAD readout are used to obtain the best coincidence time resolution (CTR). Highly integrated ASICs and DAQ electronics contribute to the timing performances of EndoTOFPET. In view of the targeted resolution of around 1 mm in the reconstructed image, we present a prototype dete...

  5. A standardised protocol for texture feature analysis of endoscopic images in gynaecological cancer

    Directory of Open Access Journals (Sweden)

    Pattichis Marios S

    2007-11-01

    Full Text Available Abstract Background In the development of tissue classification methods, classifiers rely on significant differences between texture features extracted from normal and abnormal regions. Yet, significant differences can arise due to variations in the image acquisition method. For endoscopic imaging of the endometrium, we propose a standardized image acquisition protocol to eliminate significant statistical differences due to variations in: (i the distance from the tissue (panoramic vs close up, (ii difference in viewing angles and (iii color correction. Methods We investigate texture feature variability for a variety of targets encountered in clinical endoscopy. All images were captured at clinically optimum illumination and focus using 720 × 576 pixels and 24 bits color for: (i a variety of testing targets from a color palette with a known color distribution, (ii different viewing angles, (iv two different distances from a calf endometrial and from a chicken cavity. Also, human images from the endometrium were captured and analysed. For texture feature analysis, three different sets were considered: (i Statistical Features (SF, (ii Spatial Gray Level Dependence Matrices (SGLDM, and (iii Gray Level Difference Statistics (GLDS. All images were gamma corrected and the extracted texture feature values were compared against the texture feature values extracted from the uncorrected images. Statistical tests were applied to compare images from different viewing conditions so as to determine any significant differences. Results For the proposed acquisition procedure, results indicate that there is no significant difference in texture features between the panoramic and close up views and between angles. For a calibrated target image, gamma correction provided an acquired image that was a significantly better approximation to the original target image. In turn, this implies that the texture features extracted from the corrected images provided for better

  6. Endoscopic submucosal dissection

    DEFF Research Database (Denmark)

    Pimentel-Nunes, Pedro; Dinis-Ribeiro, Mário; Ponchon, Thierry

    2015-01-01

    evidence). 2 ESGE recommends endoscopic resection with a curative intent for visible lesions in Barrett's esophagus (strong recommendation, moderate quality evidence). ESD has not been shown to be superior to EMR for excision of mucosal cancer, and for that reason EMR should be preferred. ESD may...... RECOMMENDATIONS: 1 ESGE recommends endoscopic en bloc resection for superficial esophageal squamous cell cancers (SCCs), excluding those with obvious submucosal involvement (strong recommendation, moderate quality evidence). Endoscopic mucosal resection (EMR) may be considered in such lesions when...

  7. Endoscopic Devices for Obesity.

    Science.gov (United States)

    Sampath, Kartik; Dinani, Amreen M; Rothstein, Richard I

    2016-06-01

    The obesity epidemic, recognized by the World Health Organization in 1997, refers to the rising incidence of obesity worldwide. Lifestyle modification and pharmacotherapy are often ineffective long-term solutions; bariatric surgery remains the gold standard for long-term obesity weight loss. Despite the reported benefits, it has been estimated that only 1% of obese patients will undergo surgery. Endoscopic treatment for obesity represents a potential cost-effective, accessible, minimally invasive procedure that can function as a bridge or alternative intervention to bariatric surgery. We review the current endoscopic bariatric devices including space occupying devices, endoscopic gastroplasty, aspiration technology, post-bariatric surgery endoscopic revision, and obesity-related NOTES procedures. Given the diverse devices already FDA approved and in development, we discuss the future directions of endoscopic therapies for obesity.

  8. Mueller-matrix of laser-induced autofluorescence of polycrystalline films of dried peritoneal fluid in diagnostics of endometriosis

    Science.gov (United States)

    Ushenko, Yuriy A.; Koval, Galina D.; Ushenko, Alexander G.; Dubolazov, Olexander V.; Ushenko, Vladimir A.; Novakovskaia, Olga Yu.

    2016-07-01

    This research presents investigation results of the diagnostic efficiency of an azimuthally stable Mueller-matrix method of analysis of laser autofluorescence of polycrystalline films of dried uterine cavity peritoneal fluid. A model of the generalized optical anisotropy of films of dried peritoneal fluid is proposed in order to define the processes of laser autofluorescence. The influence of complex mechanisms of both phase (linear and circular birefringence) and amplitude (linear and circular dichroism) anisotropies is taken into consideration. The interconnections between the azimuthally stable Mueller-matrix elements characterizing laser autofluorescence and different mechanisms of optical anisotropy are determined. The statistical analysis of coordinate distributions of such Mueller-matrix rotation invariants is proposed. Thereupon the quantitative criteria (statistic moments of the first to the fourth order) of differentiation of polycrystalline films of dried peritoneal fluid, group 1 (healthy donors) and group 2 (uterus endometriosis patients), are determined.

  9. Unusual optical coherence tomography and fundus autofluorescence findings of eclipse retinopathy

    Directory of Open Access Journals (Sweden)

    Kun-Hsien Li

    2012-01-01

    Full Text Available A 63-year-old female patient complained of dimness in the central field of vision in the left eye after viewing an annular partial eclipse without adequate eye protection on 22 July 2009. Fundoscopy showed a wrinkled macular surface. Fundus autofluorescence study revealed well-demarcated hyperautofluorescence at the fovea. Optical coherence tomography demonstrated tiny intraretinal cysts. Fluorescein angiography and indocyanine green angiography were unremarkable. Epimacular membrane developed in the following month with deteriorated vision. Vitrectomy, epiretinal membrane and internal limiting membrane peeling were performed. Vision was restored to 20/20 after the operation. Direct sun-gazing may damage the retinal structures resulting in macular inflammation and increased focal metabolism, which explains the hyperautofluorescence. It may also induce epimacular membrane. Fundus autofluorescence might represent a useful technique to detect subtle solar-induced injuries of the retina. The visual prognosis is favorable but prevention remains the mainstay of treatment. Public health education is mandatory in reducing visual morbidity.

  10. Gastric schwannomas: radiological features with endoscopic and pathological correlation

    Energy Technology Data Exchange (ETDEWEB)

    Hong, H.S. [Department of Radiology, Severance Hospital, Yonsei University College of Medicine, Seodaemoon-gu, Seoul (Korea, Republic of); Ha, H.K. [Department of Radiology, University of Ulsan College of Medicine, Songpa-gu, Seoul (Korea, Republic of)], E-mail: hkha@amc.seoul.kr; Won, H.J.; Byun, J.H.; Shin, Y.M.; Kim, A.Y.; Kim, P.N.; Lee, M.-G. [Department of Radiology, University of Ulsan College of Medicine, Songpa-gu, Seoul (Korea, Republic of); Lee, G.H. [Internal Medicine, University of Ulsan College of Medicine, Songpa-gu, Seoul (Korea, Republic of); Kim, M.J. [Pathology, Asan Medical Center, University of Ulsan College of Medicine, Songpa-gu, Seoul (Korea, Republic of)

    2008-05-15

    Aim: To describe the radiological, endoscopic, and pathological findings of gastric schwannomas in 16 patients. Materials and methods: The radiological, endoscopic, and pathological findings of 16 surgically proven cases of gastric schwannoma were retrospectively reviewed. All patients underwent computed tomography (CT) and four patients were evaluated with upper gastrointestinal series. Two radiologists reviewed the CT and upper gastrointestinal series images by consensus with regard to tumour size, contour, margin, and growth pattern, the presence or absence of ulcer, cystic change, and the CT enhancement pattern. Endoscopy was performed in eight of these 16 patients. Six patients underwent endoscopic ultrasonography. Pathological specimens were obtained from and reviewed in all 16 patients. Immunohistochemistry was performed for c-kit, CD34, smooth muscle actin, and S-100 protein. Results: On radiographic examination, gastric schwannomas appeared as submucosal tumours with the CT features of well-demarcated, homogeneous, and uncommonly ulcerated masses. Endoscopy with endoscopic ultrasonography demonstrated homogeneous, submucosal masses contiguous with the muscularis propria in all six examined cases. On pathological examination, gastric schwannomas appeared as well-circumscribed and homogeneous tumours in the muscularis propria and consisted microscopically of interlacing bundles of spindle cells. Strong positivity for S-100 protein was demonstrated in all 16 cases on immunohistochemistry. Conclusion: Gastric schwannomas appear as submucosal tumours of the stomach and have well-demarcated and homogeneous features on CT, endoscopic ultrasonography, and gross pathology. Immunohistochemistry consistently reveals positivity for S-100 protein in the tumours.

  11. Gastric schwannomas: radiological features with endoscopic and pathological correlation

    International Nuclear Information System (INIS)

    Hong, H.S.; Ha, H.K.; Won, H.J.; Byun, J.H.; Shin, Y.M.; Kim, A.Y.; Kim, P.N.; Lee, M.-G.; Lee, G.H.; Kim, M.J.

    2008-01-01

    Aim: To describe the radiological, endoscopic, and pathological findings of gastric schwannomas in 16 patients. Materials and methods: The radiological, endoscopic, and pathological findings of 16 surgically proven cases of gastric schwannoma were retrospectively reviewed. All patients underwent computed tomography (CT) and four patients were evaluated with upper gastrointestinal series. Two radiologists reviewed the CT and upper gastrointestinal series images by consensus with regard to tumour size, contour, margin, and growth pattern, the presence or absence of ulcer, cystic change, and the CT enhancement pattern. Endoscopy was performed in eight of these 16 patients. Six patients underwent endoscopic ultrasonography. Pathological specimens were obtained from and reviewed in all 16 patients. Immunohistochemistry was performed for c-kit, CD34, smooth muscle actin, and S-100 protein. Results: On radiographic examination, gastric schwannomas appeared as submucosal tumours with the CT features of well-demarcated, homogeneous, and uncommonly ulcerated masses. Endoscopy with endoscopic ultrasonography demonstrated homogeneous, submucosal masses contiguous with the muscularis propria in all six examined cases. On pathological examination, gastric schwannomas appeared as well-circumscribed and homogeneous tumours in the muscularis propria and consisted microscopically of interlacing bundles of spindle cells. Strong positivity for S-100 protein was demonstrated in all 16 cases on immunohistochemistry. Conclusion: Gastric schwannomas appear as submucosal tumours of the stomach and have well-demarcated and homogeneous features on CT, endoscopic ultrasonography, and gross pathology. Immunohistochemistry consistently reveals positivity for S-100 protein in the tumours

  12. Endoscopic management of biliary injuries and leaks

    Directory of Open Access Journals (Sweden)

    T S Chandrasekar

    2012-01-01

    Full Text Available Bile duct injuries and subsequent leaks can occur following laparoscopic and open cholecystectomies and also during other hepatobiliary surgeries. Various patient related and technical factors are implicated in the causation of biliary injuries. Over a period of twenty five years managing such patients of biliary injuries our team has found a practical approach to assess the cause of biliary injuries based on the symptoms, clinical examination and imaging. Bismuth classification is helpful in most of the cases. Immediate referral to a centre experienced in the management of bile duct injury and timely intervention is associated with improved outcomes. Resuscitation, correcting dyselectrolytemia, aspiration of undrained biloma and antibiotics take the priority in the management. The goal is to restore the bile conduit, and to prevent short and longterm complications such as biliary fistula, intra-abdominal abscess, biliary stricture, recurrent cholangitis and secondary biliary cirrhosis. Endoscopic therapy by reducing the transpapillary pressure gradient helps in reducing the leak. Endoscopic therapy with biliary sphincterotomy alone or with additional placement of a biliary stent/ nasobiliary drainage is advocated. In our tertiary care referral unit, we found endoscopic interventions are useful in situations where there is leak with associated CBD calculus or a foreign body, peripheral bile duct injury, cystic duct stump leak and partial bile duct injury with leak/ narrowing of the lumen. Endotherapy is not useful in case of complete transection (total cut off and complete stricture involving common hepatic or common bile ducts. In conclusion, endoscopic treatment can be considered a highly effective therapy and should be the first-line therapy in such patients. Though less successful, an endoscopic attempt is warranted in patients suffering from central bile duct leakages failing which surgical management is recommended.

  13. Endoscopic middle ear exploration in pediatric patients with conductive hearing loss.

    Science.gov (United States)

    Carter, John M; Hoff, Stephen R

    2017-05-01

    To describe our indications, findings, and outcomes for transcanal endoscopic middle ear exploration in pediatric patients with conductive hearing loss of unknown etiology, without effusions. Prospective case series for all pediatric patients undergoing totally endoscopic transcanal middle ear exploration between April 2012 and October 2015 at a pediatric tertiary care referral hospital. Demographic data, operative findings, and hearing results were reviewed. 21 cases were performed in 20 ears (1 revision). Average age at surgery was 7.98 years and average follow up was 2.1 years. Middle ear pathology identified on CT imaging was confirmed in 55% of cases while identified in 45% of cases where pre-operative imaging was non-diagnostic. 6/20 patients (30%) had an ossicular deformity. 8/20(40%) had bony ossicular fixation. 5/20(25%) had ossicular discontinuity. 2/20(10%) had facial nerve dehiscence impinging on the stapes. 15% had adhesive myringosclerosis or severe granulation causing hearing loss. Prosthetic ossiculoplasty was done in 7/21 (33.3%) of the cases, with 1 TORP, 3 PORPs, and 3 IS joint replacements. Imaging was predictive of intra-operative findings in 13/20 cases (55%). Trainees assisted in 16/21(76%) of cases. The average improvement of PTA was 11.65 dB (range -10 to 36.25), and the average ABG improved 10.19 (range -11.25 to 28.75). There were no perioperative complications or adverse events. The endoscopic transcanal approach for middle ear exploration offers excellent visualization and is one of the best applications for the endoscopes in pediatric otology cases. This is particularly helpful for "unexplained" conductive hearing loss where ossicular deformity/fixation/discontinuity is suspected. The etiology of the conductive hearing loss was definitively found in 100% of cases, and can be repaired in the same sitting when applicable. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. An optical method for reducing green fluorescence from urine during fluorescence-guided cystoscopy

    DEFF Research Database (Denmark)

    Lindvold, Lars René; Hermann, Gregers G

    2016-01-01

    Photodynamic diagnosis (PDD) of bladder tumour tissue significantly improves endoscopic diagnosis and treatment of bladder cancer in rigid cystoscopes in the operating theatre and thus reduces tumour recurrence. PDD comprises the use of blue light, which unfortunately excites green fluorescence...... this light source also is useful for exciting autofluorescence in healthy bladder mucosa. This autofluorescence then provides a contrast to the sensitized fluorescence (PDD) of tumours in the bladder....

  15. Endoscopic management of colorectal adenomas.

    Science.gov (United States)

    Meier, Benjamin; Caca, Karel; Fischer, Andreas; Schmidt, Arthur

    2017-01-01

    Colorectal adenomas are well known precursors of invasive adenocarcinoma. Colonoscopy is the gold standard for adenoma detection. Colonoscopy is far more than a diagnostic tool, as it allows effective treatment of colorectal adenomas. Endoscopic resection of colorectal adenomas has been shown to reduce the incidence and mortality of colorectal cancer. Difficult resection techniques are available, such as endoscopic mucosal resection, endoscopic submucosal dissection and endoscopic full-thickness resection. This review aims to provide an overview of the different endoscopic resection techniques and their indications, and summarizes the current recommendations in the recently published guideline of the European Society of Gastrointestinal Endoscopy.

  16. Sensitivity of endoscopic ultrasound, multidetector computed tomography, and magnetic resonance cholangiopancreatography in the diagnosis of pancreas divisum: a tertiary center experience.

    Science.gov (United States)

    Kushnir, Vladimir M; Wani, Sachin B; Fowler, Kathryn; Menias, Christine; Varma, Rakesh; Narra, Vamsi; Hovis, Christine; Murad, Faris M; Mullady, Daniel K; Jonnalagadda, Sreenivasa S; Early, Dayna S; Edmundowicz, Steven A; Azar, Riad R

    2013-04-01

    There are limited data comparing imaging modalities in the diagnosis of pancreas divisum. We aimed to: (1) evaluate the sensitivity of endoscopic ultrasound (EUS), magnetic resonance cholangiopancreatography (MRCP), and multidetector computed tomography (MDCT) for pancreas divisum; and (2) assess interobserver agreement (IOA) among expert radiologists for detecting pancreas divisum on MDCT and MRCP. For this retrospective cohort study, we identified 45 consecutive patients with pancreaticobiliary symptoms and pancreas divisum established by endoscopic retrograde pancreatography who underwent EUS and cross-sectional imaging. The control group was composed of patients without pancreas divisum who underwent endoscopic retrograde pancreatography and cross-sectional imaging. The sensitivity of EUS for pancreas divisum was 86.7%, significantly higher than the sensitivity reported in the medical records for MDCT (15.5%) or MRCP (60%) (P pancreas divisum; IOA was moderate (κ = 0.43). Endoscopic ultrasound is a sensitive test for diagnosing pancreas divisum and is superior to MDCT and MRCP. Review of MDCT studies by expert radiologists substantially raises its sensitivity for pancreas divisum.

  17. Foot-controlled robotic-enabled endoscope holder for endoscopic sinus surgery: A cadaveric feasibility study.

    Science.gov (United States)

    Chan, Jason Y K; Leung, Iris; Navarro-Alarcon, David; Lin, Weiyang; Li, Peng; Lee, Dennis L Y; Liu, Yun-hui; Tong, Michael C F

    2016-03-01

    To evaluate the feasibility of a unique prototype foot-controlled robotic-enabled endoscope holder (FREE) in functional endoscopic sinus surgery. Cadaveric study. Using human cadavers, we investigated the feasibility, advantages, and disadvantages of the robotic endoscope holder in performing endoscopic sinus surgery with two hands in five cadaver heads, mimicking a single nostril three-handed technique. The FREE robot is relatively easy to use. Setup was quick, taking less than 3 minutes from docking the robot at the head of the bed to visualizing the middle meatus. The unit is also relatively small, takes up little space, and currently has four degrees of freedom. The learning curve for using the foot control was short. The use of both hands was not hindered by the presence of the endoscope in the nasal cavity. The tremor filtration also aided in the smooth movement of the endoscope, with minimal collisions. The FREE endoscope holder in an ex-vivo cadaver test corroborated the feasibility of the robotic prototype, which allows for a two-handed approach to surgery equal to a single nostril three-handed technique without the holder that may reduce operating time. Further studies will be needed to evaluate its safety profile and use in other areas of endoscopic surgery. NA. Laryngoscope, 126:566-569, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  18. Characteristic appearances of fundus autofluorescence in treatment-naive and active polypoidal choroidal vasculopathy: a retrospective study of 170 patients.

    Science.gov (United States)

    Zhao, Xinyu; Xia, Song; Chen, Youxin

    2018-06-01

    To investigate the characteristic appearances of fundus autofluorescence (FAF) in patients with treatment-naive and active polypoidal choroidal vasculopathy (PCV). Cases with the diagnosis of treatment-naive and active PCV from November 2012 to May 2017 at Peking Union Medical College Hospital were retrospectively reviewed. All patients underwent comprehensive ophthalmologic examination. Autofluorescence (AF) findings were described at the retinal sites of the corresponding lesions identified and diagnosed using indocyanine green angiography and spectral-domain optical coherence tomography. One hundred seventy patients with 192 affected eyes were included. The logMAR BCVA of the patients were 0.53 ± 0.28. The six AF patterns of 243 polypoidal lesions were confluent hypo-AF with hyper-AF ring (49.8%), confluent hypo-AF (22.6%), hyper-AF with hypo-AF ring (3.7%), granular hypo-AF (7.0%), blocked hypo-AF due to hemorrhage (8.6%), and polyps without apparent AF changes (8.2%). For 146 branching vascular networks (BVNs), 97.3% were granular hypo-AF, and others were blocked hypo-AF due to hemorrhage. In eyes with treatment-naive and active PCV, the polypoidal lesions and BVNs induce characteristic FAF changes. FAF images provide reliable adjunct reference for the diagnosis of PCV.

  19. Learning endoscopic resection in the esophagus

    NARCIS (Netherlands)

    van Vilsteren, Frederike G. I.; Pouw, Roos E.; Herrero, Lorenza Alvarez; Bisschops, Raf; Houben, Martin; Peters, Frans T. M.; Schenk, B. E.; Weusten, Bas L. A. M.; Schoon, Erik J.; Bergman, Jacques J. G. H. M.

    Background: Endoscopic resection is the cornerstone of endoscopic management of esophageal early neoplasia. However, endoscopic resection is a complex technique requiring knowledge and expertise. Our aims were to identify the most important learning points in performing endoscopic resection in a

  20. Classification of atrophic mucosal patterns on Blue LASER Imaging for endoscopic diagnosis of Helicobacter pylori-related gastritis: A retrospective, observational study.

    Science.gov (United States)

    Nishikawa, Yoshiyuki; Ikeda, Yoshio; Murakami, Hidehiro; Hori, Shin-Ichiro; Hino, Kaori; Sasaki, Chise; Nishikawa, Megumi

    2018-01-01

    Atrophic gastritis can be classified according to characteristic mucosal patterns observed by Blue LASER Imaging (BLI) in a medium-range to distant view. To facilitate the endoscopic diagnosis of Helicobacter pylori (HP)-related gastritis, we investigated whether atrophic mucosal patterns correlated with HP infection based on the image interpretations of three endoscopists blinded to clinical features. This study included 441 patients diagnosed as having atrophic gastritis by upper gastrointestinal endoscopy at Nishikawa Gastrointestinal Clinic between April 1, 2015 and March 31, 2016. The presence/absence of HP infection was not taken into consideration. Endoscopy was performed using a Fujifilm EG-L580NW scope. Atrophic mucosal patterns observed by BLI were classified into Spotty, Cracked and Mottled. Image interpretation results were that 89, 122 and 228 patients had the Spotty, Cracked and Mottled patterns, respectively, and 2 patients an undetermined pattern. Further analyses were performed on 439 patients, excluding the 2 with undetermined patterns. The numbers of patients testing negative/positive for HP infection in the Spotty, Cracked and Mottled pattern groups were 12/77, 105/17, and 138/90, respectively. The specificity, positive predictive value and positive likelihood ratio for endoscopic diagnosis with positive HP infection based on the Spotty pattern were 95.3%, 86.5% and 8.9, respectively. In all patients with the Spotty pattern before HP eradication, the Cracked pattern was observed on subsequent post-eradication endoscopy. The Spotty pattern may represent the presence of HP infection, the Cracked pattern, a post-inflammatory change as seen after HP eradication, and the Mottled pattern, intestinal metaplasia.

  1. The utility of high-resolution intraoperative MRI in endoscopic transsphenoidal surgery for pituitary macroadenomas: early experience in the Advanced Multimodality Image Guided Operating suite

    Science.gov (United States)

    Zaidi, Hasan A.; De Los Reyes, Kenneth; Barkhoudarian, Garni; Litvack, Zachary N.; Bi, Wenya Linda; Rincon-Torroella, Jordina; Mukundan, Srinivasan; Dunn, Ian F.; Laws, Edward R.

    2016-01-01

    Objective Endoscopic skull base surgery has become increasingly popular among the skull base surgery community, with improved illumination and angled visualization potentially improving tumor resection rates. Intraoperative MRI (iMRI) is used to detect residual disease during the course of the resection. This study is an investigation of the utility of 3-T iMRI in combination with transnasal endoscopy with regard to gross-total resection (GTR) of pituitary macroadenomas. Methods The authors retrospectively reviewed all endoscopic transsphenoidal operations performed in the Advanced Multimodality Image Guided Operating (AMIGO) suite from November 2011 to December 2014. Inclusion criteria were patients harboring presumed pituitary macroadenomas with optic nerve or chiasmal compression and visual loss, operated on by a single surgeon. Results Of the 27 patients who underwent transsphenoidal resection in the AMIGO suite, 20 patients met the inclusion criteria. The endoscope alone, without the use of iMRI, would have correctly predicted 13 (65%) of 20 cases. Gross-total resection was achieved in 12 patients (60%) prior to MRI. Intraoperative MRI helped convert 1 STR and 4 NTRs to GTRs, increasing the number of GTRs from 12 (60%) to 16 (80%). Conclusions Despite advances in visualization provided by the endoscope, the incidence of residual disease can potentially place the patient at risk for additional surgery. The authors found that iMRI can be useful in detecting unexpected residual tumor. The cost-effectiveness of this tool is yet to be determined. PMID:26926058

  2. Optical coherence tomography and fundus autofluorescence findings in presumed congenital simple retinal pigment epithelium hamartoma

    Directory of Open Access Journals (Sweden)

    Baskaran, Prabu

    2017-10-01

    Full Text Available Aim: Presumed congenital simple retinal pigment epithelium hamartoma is a rare benign lesion of the macula that mimics congenital hypertrophy of the retinal pigment epithelium (RPE and combined hamartoma of the retina and the RPE; newer imaging modalities can help in diagnosis. We report three patients with presumed congenital simple RPE hamartoma, and describe the enhanced-depth imaging optical coherence tomography (EDI-OCT and fundus autofluorescence (FAF findings. Methods: Two patients were asymptomatic; one had an intraocular foreign body in addition to the hamartoma. All had a similar jet black, elevated lesion in the macula, sparing the fovea. EDI-OCT showed a characteristic hyperreflective layer with complete optical shadowing of the deeper layers; FAF showed pronounced hypoautofluorescence of the lesion. Conclusion: Multimodal imaging with FAF and EDI-OCT can help to differentiate simple RPE hamartoma from similar RPE lesions, and may serve as a useful adjunct to clinical diagnosis of this rare tumor. We present the second largest series of presumed congenital simple RPE hamartoma, and – to the best of our knowledge – the first report of FAF findings of this tumor.

  3. Simulation, image reconstruction and SiPM characterisation for a novel endoscopic positron emission tomography detector

    Energy Technology Data Exchange (ETDEWEB)

    Zvolsky, Milan

    2017-12-15

    In the scope of the EndoTOFPET-US project, a novel multimodal device for ultrasound (US) endoscopy and positron emission tomography (PET) is being developed. The project aims at detecting and quantifying morphologic and functional biomarkers and developing new biomarkers for pancreas and prostate oncology. The detector system comprises a small detector probe mounted on an ultrasound endoscope and an external detector plate. The detection of the gamma rays is realised by scintillator crystals with Silicon Photomultiplier (SiPM) read-out. For the characterisation of over 4000 SiPMs for the external plate, an automatised measurement and data analysis procedure is established. The key properties of the SiPMs like breakdown voltage and dark count rate (DCR) are extracted. This knowledge is needed both as a quality assurance as well as for the calibration of the detector. The spread between minimum and maximum breakdown voltage within a SiPM array of 4 x 4 is at maximum 0.43 V with a mean of 0.15 V and an RMS of 0.06 V. This assures the optimal biasing of each SiPM at its individual operating voltage. The mean DCR amounts to 1.49 MHz with an RMS of 0.54 MHz and is thus well below the acceptable threshold of 3 MHz. Two spare modules from the external plate are re-measured and analysed several years after the module assembly, revealing a potential alteration of the SiPM noise properties over time. For the characterisation of SiPMs from different vendors, a software framework for the automatic extraction of performance parameters from pulseheight spectra, including a t of the entire spectrum, is developed and tested. In order to facilitate the modelling of the response of the EndoTOFPET-US detector, a framework is developed which is built around the Geant4-based simulation toolkit GAMOS, to simulate and reconstruct realistic imaging scenarios with this asymmetric PET detector. The simulation studies are used to compare different possible detector designs, guide the

  4. Simulation, image reconstruction and SiPM characterisation for a novel endoscopic positron emission tomography detector

    International Nuclear Information System (INIS)

    Zvolsky, Milan

    2017-12-01

    In the scope of the EndoTOFPET-US project, a novel multimodal device for ultrasound (US) endoscopy and positron emission tomography (PET) is being developed. The project aims at detecting and quantifying morphologic and functional biomarkers and developing new biomarkers for pancreas and prostate oncology. The detector system comprises a small detector probe mounted on an ultrasound endoscope and an external detector plate. The detection of the gamma rays is realised by scintillator crystals with Silicon Photomultiplier (SiPM) read-out. For the characterisation of over 4000 SiPMs for the external plate, an automatised measurement and data analysis procedure is established. The key properties of the SiPMs like breakdown voltage and dark count rate (DCR) are extracted. This knowledge is needed both as a quality assurance as well as for the calibration of the detector. The spread between minimum and maximum breakdown voltage within a SiPM array of 4 x 4 is at maximum 0.43 V with a mean of 0.15 V and an RMS of 0.06 V. This assures the optimal biasing of each SiPM at its individual operating voltage. The mean DCR amounts to 1.49 MHz with an RMS of 0.54 MHz and is thus well below the acceptable threshold of 3 MHz. Two spare modules from the external plate are re-measured and analysed several years after the module assembly, revealing a potential alteration of the SiPM noise properties over time. For the characterisation of SiPMs from different vendors, a software framework for the automatic extraction of performance parameters from pulseheight spectra, including a t of the entire spectrum, is developed and tested. In order to facilitate the modelling of the response of the EndoTOFPET-US detector, a framework is developed which is built around the Geant4-based simulation toolkit GAMOS, to simulate and reconstruct realistic imaging scenarios with this asymmetric PET detector. The simulation studies are used to compare different possible detector designs, guide the

  5. Endoscopic visualization of luminal organ and great vessels with three dimensional CT scanner

    International Nuclear Information System (INIS)

    Kobayashi, Hisashi; Okumura, Toshiyuki; Amemiya, Ryuta; Hasegawa, Hiroshi

    1992-01-01

    Thirty cases examined by three dimensional CT scanner (3DCT) are reported. The observation of inner view using 3DCT were performed in 12 large vessels with vascular disorder, 10 pulmonary bronchi with lung cancer and 8 common bile ducts involved obstructive disease. In order to visualize interface of the lumen, a new software, which was developed by HITACHI MEDICO Inc., was used. In all cases but one the inner view of the luminal organ was clearly demonstrated as 3D images and it was possible to judge some changes of luminal interface involved by the diseases. The 3DCT endoscopic image might be useful as a new endoscopic technique without fiberscopy. (author)

  6. THE EFFECT OF PHOTOPIGMENT BLEACHING ON FUNDUS AUTOFLUORESCENCE IN ACUTE CENTRAL SEROUS CHORIORETINOPATHY.

    Science.gov (United States)

    Choi, Kwang-Eon; Yun, Cheolmin; Kim, Young-Ho; Kim, Seong-Woo; Oh, Jaeryung; Huh, Kuhl

    2017-03-01

    To evaluate the effect of photobleaching on fundus autofluorescence (FAF) images in acute central serous chorioretinopathy. We obtained prephotobleaching and postphotobleaching images using an Optomap 200Tx, and photobleaching was induced with a Heidelberg Retina Angiograph 2. Degrees of photobleaching were assessed as grayscale values in Optomap images. Concordances among the three kinds of images were analyzed. Hyper-AF lesions in prephotobleaching images were classified as Type 1 (changed to normal-AF after photobleaching) and Type 2 (unchanged after photobleaching). The FAF composite patterns of central serous chorioretinopathy lesions were classified as diffuse or mottled. Initial and final best-corrected visual acuity, central retinal thickness, and disease duration were compared according to fovea FAF type. Forty-one eyes of 41 patients were analyzed. The lesion brightness of postphotobleaching Optomap FAF showed greater concordance with Heidelberg Retina Angiograph 2 FAF (94.74%) than the prephotobleaching Optomap FAF (80.49%). Eyes with Type 1 fovea had greater initial and final best-corrected visual acuity (20/23 vs. 20/41, 20/21 vs. 20/32, P < 0.0001, P = 0.001, respectively) and shorter disease duration (19.68 ± 12.98 vs. 51.55 ± 44.98 days, P = 0.043) than those with Type 2 fovea. However, eyes with diffuse Type 2 fovea had only lower initial and final best-corrected visual acuity (20/23 vs. 20/45, 20/21 vs. 20/36, P < 0.0001, P < 0.0001, respectively) than those with Type 1 fovea. Understanding the photobleaching effect is necessary for the accurate interpretation of FAF images. Furthermore, comparing prephotobleaching and postphotobleaching FAF images may be helpful for estimation of lesion status in central serous chorioretinopathy.

  7. Contrast-enhanced endoscopic ultrasonography in digestive diseases.

    Science.gov (United States)

    Hirooka, Yoshiki; Itoh, Akihiro; Kawashima, Hiroki; Ohno, Eizaburo; Itoh, Yuya; Nakamura, Yosuke; Hiramatsu, Takeshi; Sugimoto, Hiroyuki; Sumi, Hajime; Hayashi, Daijiro; Ohmiya, Naoki; Miyahara, Ryoji; Nakamura, Masanao; Funasaka, Kohei; Ishigami, Masatoshi; Katano, Yoshiaki; Goto, Hidemi

    2012-10-01

    Contrast-enhanced endoscopic ultrasonography (CE-EUS) was introduced in the early 1990s. The concept of the injection of carbon dioxide microbubbles into the hepatic artery as a contrast material (enhanced ultrasonography) led to "endoscopic ultrasonographic angiography". After the arrival of the first-generation contrast agent, high-frequency (12 MHz) EUS brought about the enhancement of EUS images in the diagnosis of pancreatico-biliary diseases, upper gastrointestinal (GI) cancer, and submucosal tumors. The electronic scanning endosonoscope with both radial and linear probes enabled the use of high-end ultrasound machines and depicted the enhancement of both color/power Doppler flow-based imaging and harmonic-based imaging using second-generation contrast agents. Many reports have described the usefulness of the differential diagnosis of pancreatic diseases and other abdominal lesions. Quantitative evaluation of CE-EUS images was an objective method of diagnosis using the time-intensity curve (TIC), but it was limited to the region of interest. Recently developed Inflow Time Mapping™ can be generated from stored clips and used to display the pattern of signal enhancement with time after injection, offering temporal difference of contrast agents and improved tumor characterization. On the other hand, three-dimensional CE-EUS images added new information to the literature, but lacked positional information. Three-dimensional CE-EUS with accurate positional information is awaited. To date, most reports have been related to pancreatic lesions or lymph nodes. Hemodynamic analysis might be of use for diseases in other organs: upper GI cancer diagnosis, submucosal tumors, and biliary disorders, and it might also provide functional information. Studies of CE-EUS in diseases in many other organs will increase in the near future.

  8. Dosimetry in endoscopic examinations

    International Nuclear Information System (INIS)

    Aldred, Martha Aurelia; Paes, Walter Siqueira; Fausto, Agnes M.F.; Nucci, Jose Roberto; Yoshimura, Elisabeth Mateus; Okuno, Emico; Maruta, Luis Massuo

    1996-01-01

    Equivalent and effective doses in occupational exposures are evaluated considering that some specific endoscopic examinations, radiographic and fluoroscopic images of patients are taken with the medical staff near to the radiation field. Examinations are simulated using an anthropomorphic phantom as a member of the medical staff. Thermoluminescent dosemeters are attached in several positions of the phantom in order to determine some organ doses. From the comparison between the doses experimentally determined and the International and the Brazilian recommended occupational dose limits, the maximum number of examination that any member of the staff can perform was calculated

  9. [Virtual bronchoscopy: the correlation between endoscopic simulation and bronchoscopic findings].

    Science.gov (United States)

    Salvolini, L; Gasparini, S; Baldelli, S; Bichi Secchi, E; Amici, F

    1997-11-01

    We carried out a preliminary clinical validation of 3D spiral CT virtual endoscopic reconstructions of the tracheobronchial tree, by comparing virtual bronchoscopic images with actual endoscopic findings. Twenty-two patients with tracheobronchial disease suspected at preliminary clinical, cytopathological and plain chest film findings were submitted to spiral CT of the chest and bronchoscopy. CT was repeated after endobronchial therapy in 2 cases. Virtual endoscopic shaded-surface-display views of the tracheobronchial tree were reconstructed from reformatted CT data with an Advantage Navigator software. Virtual bronchoscopic images were preliminarily evaluated with a semi-quantitative quality score (excellent/good/fair/poor). The depiction of consecutive airway branches was then considered. Virtual bronchoscopies were finally submitted to double-blind comparison with actual endoscopies. Virtual image quality was considered excellent in 8 cases, good in 14 and fair in 2. Virtual exploration was stopped at the lobar bronchi in one case only; the origin of segmental bronchi was depicted in 23 cases and that of some subsegmental branches in 2 cases. Agreement between actual and virtual bronchoscopic findings was good in all cases but 3 where it was nevertheless considered satisfactory. The yield of clinically useful information differed in 8/24 cases: virtual reconstructions provided more information than bronchoscopy in 5 cases and vice versa in 3. Virtual reconstructions are limited in that the procedure is long and difficult and needing a strictly standardized threshold value not to alter virtual findings. Moreover, the reconstructed surface lacks transparency, there is the partial volume effect and the branches < or = 4 pixels phi and/or meandering ones are difficult to explore. Our preliminary data are encouraging. Segmental bronchi were depicted in nearly all cases, except for the branches involved by disease. Obstructing lesions could be bypassed in some cases

  10. Endoscopic submucosal dissection for locally recurrent colorectal lesions after previous endoscopic mucosal resection.

    Science.gov (United States)

    Zhou, Pinghong; Yao, Liqing; Qin, Xinyu; Xu, Meidong; Zhong, Yunshi; Chen, Weifeng

    2009-02-01

    The objective of this study was to determine the efficacy and safety of endoscopic submucosal dissection for locally recurrent colorectal cancer after previous endoscopic mucosal resection. A total of 16 patients with locally recurrent colorectal lesions were enrolled. A needle knife, an insulated-tip knife and a hook knife were used to resect the lesion along the submucosa. The rate of the curative resection, procedure time, and incidence of complications were evaluated. Of 16 lesions, 15 were completely resected with endoscopic submucosal dissection, yielding an en bloc resection rate of 93.8 percent. Histologic examination confirmed that lateral and basal margins were cancer-free in 14 patients (87.5 percent). The average procedure time was 87.2 +/- 60.7 minutes. None of the patients had immediate or delayed bleeding during or after endoscopic submucosal dissection. Perforation in one patient (6.3 percent) was the only complication and was managed conservatively. The mean follow-up period was 15.5 +/- 6.8 months; none of the patients experienced lesion residue or recurrence. Endoscopic submucosal dissection appears to be effective for locally recurrent colorectal cancer after previous endoscopic mucosal resection, making it possible to resect whole lesions and provide precise histologic information.

  11. Endoscopic Laser-Based 3D Imaging for Functional Voice Diagnostics

    Directory of Open Access Journals (Sweden)

    Marion Semmler

    2017-06-01

    Full Text Available Recently, we reported on the in vivo application of a miniaturized measuring device for 3D visualization of the superior vocal fold vibrations from high-speed recordings in combination with a laser projection unit (LPU. As a long-term vision for this proof of principle, we strive to integrate the further developed laserendoscopy as a diagnostic method in daily clinical routine. The new LPU mainly comprises a Nd:YAG laser source (532 nm/CW/2 ω and a diffractive optical element (DOE generating a regular laser grid (31 × 31 laser points that is projected on the vocal folds. By means of stereo triangulation, the 3D coordinates of the laser points are reconstructed from the endoscopic high-speed footage. The new design of the laserendoscope constitutes a compromise between robust image processing and laser safety regulations. The algorithms for calibration and analysis are now optimized with respect to their overall duration and the number of required interactions, which is objectively assessed using binary classifiers. The sensitivity and specificity of the calibration procedure are increased by 40.1% and 22.3%, which is statistically significant. The overall duration for the laser point detection is reduced by 41.9%. The suggested semi-automatic reconstruction software represents an important stepping-stone towards potential real time processing and a comprehensive, objective diagnostic tool of evidence-based medicine.

  12. Endoscopic case

    Directory of Open Access Journals (Sweden)

    Fernando Pereira

    2017-01-01

    Full Text Available We present the case of a ten-year-old female patient referred to Gastroenterolgy consultation for abdominal pain and cramping, usually worse after eating, recurring diarrhoea, hypochromic and microcytic anaemia with low serum iron and ferritin levels. Moderate to severe Crohn’s disease of the terminal ileum e right colon (L3 was diagnosed, based on endoscopic image and biopsy. The patient was treated with prednisone and azathioprine, but after one year of treatment she was steroids dependent and treatment was switched to infliximab. One year after beginning this treatment, the patient achieved remission (clinical and laboratorial parameters. A control colonoscopy showed mucosal healing with scars and deformation with stenosis of ileocecal valve (Figures 1-2. Surgical intervention will be probably necessary in near future.

  13. Contrast-enhanced harmonic endoscopic ultrasound

    DEFF Research Database (Denmark)

    Săftoiu, A; Dietrich, C F; Vilmann, P

    2012-01-01

    Second-generation intravenous blood-pool ultrasound contrast agents are increasingly used in endoscopic ultrasound (EUS) for characterization of microvascularization, differential diagnosis of benign and malignant focal lesions, and improving staging and guidance of therapeutic procedures. Although...... initially used as Doppler signal enhancers, second-generation microbubble contrast agents are now used with specific contrast harmonic imaging techniques, which benefit from the highly nonlinear behavior of the microbubbles. Contrast-specific modes based on multi-pulse technology are used to perform...... contrast-enhanced harmonic EUS based on a very low mechanical index (0.08 - 0.12). Quantification techniques based on dynamic contrast-enhanced ultrasound have been recommended for perfusion imaging and monitoring of anti-angiogenic treatment, mainly based on time-intensity curve analysis. Most...

  14. Creating Panoramic Images for Bladder Fluorescence Endoscopy

    Directory of Open Access Journals (Sweden)

    A. Behrens

    2008-01-01

    Full Text Available The medical diagnostic analysis and therapy of urinary bladder cancer based on endoscopes are state of the art in urological medicine. Due to the limited field of view of endoscopes, the physician can examine only a small part of the whole operating field at once. This constraint makes visual control and navigation difficult, especially in hollow organs. A panoramic image, covering a larger field of view, can overcome this difficulty. Directly motivated by a physician we developed an image mosaicing algorithm for endoscopic bladder fluorescence video sequences. In this paper, we present an approach which is capable of stitching single endoscopic video images to a combined panoramic image. Based on SIFT features we estimate a 2-D homography for each image pair, using an affine model and an iterative model-fitting algorithm. We then apply the stitching process and perform a mutual linear interpolation. Our panoramic image results show a correct stitching and lead to a better overview and understanding of the operation field. 

  15. Characterization and functional correlation of multiple imaging modalities with focal choroidal excavation

    Directory of Open Access Journals (Sweden)

    Yun-Chen Chen

    2018-05-01

    Full Text Available Background: To investigate the clinical manifestations and imaging features of near-infrared autofluorescence (NIA, infrared reflectance (IR, fundus autofluorescence (FAF, indocyanine green angiography (ICGA and fluorescein angiography (FAG in the detection of patients with focal choroidal excavation (FCE identified by cross-sectional spectral-domain optical coherence tomography (SD-OCT. Methods: This retrospective cross-sectional study included 12 eyes of 10 Taiwanese patients with FCE diagnosed by SD-OCT. The areas and depths of FCE in serial cross-sectional and en-face OCT were compared in different imaging modalities. NIA, IR, FAF, ICGA and FAG images were obtained. Best corrected visual acuity, subjective distortion area in the Amsler grid and history of maculopathies were also recorded. Results: In areas where the choroid started to excavate as shown in SD-OCT, hypo-autofluorescence in NIA was noted. The area of hypo-fluorescence in NIA of all the FCE lesions showed good correlation with the size. The area of FCE was associated with complications such as choroidal neovascularization and central serous chorioretinopathy (p = 0.014, d.f = 1 and the volume (NIA area × Depth measured by SD-OCT × 1/3 was associated with subjective distortion strongly (p = 0.051, Spearman's correlation = 0.600. Conclusion: Among all image modalities, NIA was the most sensitive tool in area measurement of FCE and peripheral lesion detection. Also, the volume of FCE was associated with subjective distortion and the area was related to complications. Recording the area and volume of FCE could play an important role in monitoring complications. Keywords: Choroid-retina disease, Focal choroidal excavation, Near-infrared autofluorescence, Spectral-domain optical coherence tomography

  16. Endoscopic therapy of neoplasia related to Barrett's esophagus and endoscopic palliation of esophageal cancer.

    Science.gov (United States)

    Vignesh, Shivakumar; Hoffe, Sarah E; Meredith, Kenneth L; Shridhar, Ravi; Almhanna, Khaldoun; Gupta, Akshay K

    2013-04-01

    Barrett's esophagus (BE) is the most important identifiable risk factor for the progression to esophageal adenocarcinoma. This article reviews the current endoscopic therapies for BE with high-grade dysplasia and intramucosal cancer and briefly discusses the endoscopic palliation of advanced esophageal cancer. The diagnosis of low-grade or high-grade dysplasia (HGD) is based on several cytologic criteria that suggest neoplastic transformation of the columnar epithelium. HGD and carcinoma in situ are regarded as equivalent. The presence of dysplasia, particularly HGD, is also a risk factor for synchronous and metachronous adenocarcinoma. Dysplasia is a marker of adenocarcinoma and also has been shown to be the preinvasive lesion. Esophagectomy has been the conventional treatment for T1 esophageal cancer and, although debated, is an appropriate option in some patients with HGD due to the presence of occult cancer in over one-third of patients. Endoscopic ablative modalities (eg, photodynamic therapy and cryoablation) and endoscopic resection techniques (eg, endoscopic mucosal resection) have demonstrated promising results. The significant morbidity and mortality of esophagectomy makes endoscopic treatment an attractive potential option.

  17. Optically-tracked handheld fluorescence imaging platform for monitoring skin response in the management of soft tissue sarcoma

    Science.gov (United States)

    Chamma, Emilie; Qiu, Jimmy; Lindvere-Teene, Liis; Blackmore, Kristina M.; Majeed, Safa; Weersink, Robert; Dickie, Colleen I.; Griffin, Anthony M.; Wunder, Jay S.; Ferguson, Peter C.; DaCosta, Ralph S.

    2015-07-01

    Standard clinical management of extremity soft tissue sarcomas includes surgery with radiation therapy. Wound complications (WCs) arising from treatment may occur due to bacterial infection and tissue breakdown. The ability to detect changes in these parameters during treatment may lead to earlier interventions that mitigate WCs. We describe the use of a new system composed of an autofluorescence imaging device and an optical three-dimensional tracking system to detect and coregister the presence of bacteria with radiation doses. The imaging device visualized erythema using white light and detected bacterial autofluorescence using 405-nm excitation light. Its position was tracked relative to the patient using IR reflective spheres and registration to the computed tomography coordinates. Image coregistration software was developed to spatially overlay radiation treatment plans and dose distributions on the white light and autofluorescence images of the surgical site. We describe the technology, its use in the operating room, and standard operating procedures, as well as demonstrate technical feasibility and safety intraoperatively. This new clinical tool may help identify patients at greater risk of developing WCs and investigate correlations between radiation dose, skin response, and changes in bacterial load as biomarkers associated with WCs.

  18. An Automated Self-Learning Quantification System to Identify Visible Areas in Capsule Endoscopy Images.

    Science.gov (United States)

    Hashimoto, Shinichi; Ogihara, Hiroyuki; Suenaga, Masato; Fujita, Yusuke; Terai, Shuji; Hamamoto, Yoshihiko; Sakaida, Isao

    2017-08-01

    Visibility in capsule endoscopic images is presently evaluated through intermittent analysis of frames selected by a physician. It is thus subjective and not quantitative. A method to automatically quantify the visibility on capsule endoscopic images has not been reported. Generally, when designing automated image recognition programs, physicians must provide a training image; this process is called supervised learning. We aimed to develop a novel automated self-learning quantification system to identify visible areas on capsule endoscopic images. The technique was developed using 200 capsule endoscopic images retrospectively selected from each of three patients. The rate of detection of visible areas on capsule endoscopic images between a supervised learning program, using training images labeled by a physician, and our novel automated self-learning program, using unlabeled training images without intervention by a physician, was compared. The rate of detection of visible areas was equivalent for the supervised learning program and for our automatic self-learning program. The visible areas automatically identified by self-learning program correlated to the areas identified by an experienced physician. We developed a novel self-learning automated program to identify visible areas in capsule endoscopic images.

  19. Optical characterization and polarization calibration for rigid endoscopes

    Science.gov (United States)

    Garcia, Missael; Gruev, Viktor

    2017-02-01

    Polarization measurements give orthogonal information to spectral images making them a great tool in the characterization of environmental parameters in nature. Thus, polarization imagery has proven to be remarkably useful in a vast range of biomedical applications. One such application is the early diagnosis of flat cancerous lesions in murine colorectal tumor models, where polarization data complements NIR fluorescence analysis. Advances in nanotechnology have led to compact and precise bio-inspired imaging sensors capable of accurately co-registering multidimensional spectral and polarization information. As more applications emerge for these imagers, the optics used in these instruments get very complex and can potentially compromise the original polarization state of the incident light. Here we present a complete optical and polarization characterization of three rigid endoscopes of size 1.9mm x 10cm (Karl Storz, Germany), 5mm x 30cm, and 10mm x 33cm (Olympus, Germany), used in colonoscopy for the prevention of colitis-associated cancer. Characterization results show that the telescope optics act as retarders and effectively depolarize the linear component. These incorrect readings can cause false-positives or false-negatives leading to an improper diagnosis. In this paper, we offer a polarization calibration scheme for these endoscopes based on Mueller calculus. By modeling the optical properties from training data as real-valued Mueller matrices, we are able to successfully reconstruct the initial polarization state acquired by the imaging system.

  20. Endoscope-Assisted Transoral Fixation of Mandibular Condyle Fractures: Submandibular Versus Transoral Endoscopic Approach.

    Science.gov (United States)

    Hwang, Na-Hyun; Lee, Yoon-Hwan; You, Hi-Jin; Yoon, Eul-Sik; Kim, Deok-Woo

    2016-07-01

    In recent years, endoscope-assisted transoral approach for condylar fracture treatment has attracted much attention. However, the surgical approach is technically challenging: the procedure requires specialized instruments and the surgeons experience a steep learning curve. During the transoral endoscopic (TE) approach several instruments are positioned through a narrow oral incision making endoscope maneuvering very difficult. For this reason, the authors changed the entry port of the endoscope from transoral to submandibular area through a small stab incision. The aim of this study is to assess the advantage of using the submandibular endoscopic intraoral approach (SEI).The SEI approach requires intraoral incision for fracture reduction and fixation, and 4 mm size submandibular stab incision for endoscope and traction wires. Fifteen patients with condyle neck and subcondyle fractures were operated under the submandibular approach and 15 patients with the same diagnosis were operated under the standard TE approach.The SEI approach allowed clear visualization of the posterior margin of the ramus and condyle, and the visual axis was parallel to the condyle ramus unit. The TE approach clearly shows the anterior margin of the condyle and the sigmoid notch. The surgical time of the SEI group was 128 minutes and the TE group was 120 minutes (P >0.05). All patients in the TE endoscope group were fixated with the trocar system, but only 2 lower neck fracture patients in the SEI group required a trocar. The other 13 subcondyle fractures were fixated with an angulated screw driver (P <0.05). There were no differences in complication and surgical outcomes.The submandibular endoscopic approach has an advantage of having more space with good visualization, and facilitated the use of an angulated screw driver.

  1. Miniature, minimally invasive, tunable endoscope for investigation of the middle ear.

    Science.gov (United States)

    Pawlowski, Michal E; Shrestha, Sebina; Park, Jesung; Applegate, Brian E; Oghalai, John S; Tkaczyk, Tomasz S

    2015-06-01

    We demonstrate a miniature, tunable, minimally invasive endoscope for diagnosis of the auditory system. The probe is designed to sharply image anatomical details of the middle ear without the need for physically adjusting the position of the distal end of the endoscope. This is achieved through the addition of an electrowetted, tunable, electronically-controlled lens to the optical train. Morphological imaging is enabled by scanning light emanating from an optical coherence tomography system. System performance was demonstrated by imaging part of the ossicular chain and wall of the middle ear cavity of a normal mouse. During the experiment, we electronically moved the plane of best focus from the incudo-stapedial joint to the stapedial artery. Repositioning the object plane allowed us to image anatomical details of the middle ear beyond the depth of field of a static optical system. We also demonstrated for the first time to our best knowledge, that an optical system with an electrowetted, tunable lens may be successfully employed to measure sound-induced vibrations within the auditory system by measuring the vibratory amplitude of the tympanic membrane in a normal mouse in response to pure tone stimuli.

  2. Prediction of Helicobacter pylori status by conventional endoscopy, narrow-band imaging magnifying endoscopy in stomach after endoscopic resection of gastric cancer.

    Science.gov (United States)

    Yagi, Kazuyoshi; Saka, Akiko; Nozawa, Yujiro; Nakamura, Atsuo

    2014-04-01

    To reduce the incidence of metachronous gastric carcinoma after endoscopic resection of early gastric cancer, Helicobacter pylori eradication therapy has been endorsed. It is not unusual for such patients to be H. pylori negative after eradication or for other reasons. If it were possible to predict H. pylori status using endoscopy alone, it would be very useful in clinical practice. To clarify the accuracy of endoscopic judgment of H. pylori status, we evaluated it in the stomach after endoscopic submucosal dissection (ESD) of gastric cancer. Fifty-six patients treated by ESD were enrolled. The diagnostic criteria for H. pylori status by conventional endoscopy and narrow-band imaging (NBI)-magnifying endoscopy were decided, and H. pylori status was judged by two endoscopists. Based on the H. pylori stool antigen test as a diagnostic gold standard, conventional endoscopy and NBI-magnifying endoscopy were compared for their sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Interobserver agreement was assessed in terms of κ value. Interobserver agreement was moderate (0.56) for conventional endoscopy and substantial (0.77) for NBI-magnifying endoscopy. The sensitivity, specificity, PPV, and NPV were 0.79, 0.52, 0.70, and 0.63 for conventional endoscopy and 0.91, 0.83, 0.88, and 0.86 for NBI-magnifying endoscopy, respectively. Prediction of H. pylori status using NBI-magnifying endoscopy is practical, and interobserver agreement is substantial. © 2013 John Wiley & Sons Ltd.

  3. Development and evaluation of a light-emitting diode endoscopic light source

    Science.gov (United States)

    Clancy, Neil T.; Li, Rui; Rogers, Kevin; Driscoll, Paul; Excel, Peter; Yandle, Ron; Hanna, George; Copner, Nigel; Elson, Daniel S.

    2012-03-01

    Light-emitting diode (LED) based endoscopic illumination devices have been shown to have several benefits over arclamp systems. LEDs are energy-efficient, small, durable, and inexpensive, however their use in endoscopy has been limited by the difficulty in efficiently coupling enough light into the endoscopic light cable. We have demonstrated a highly homogenised lightpipe LED light source that combines the light from four Luminus LEDs emitting in the red, green, blue and violet using innovative dichroics that maximise light throughput. The light source spectrally combines light from highly divergent incoherent sources that have a Lambertian intensity profile to provide illumination matched to the acceptance numerical aperture of a liquid light guide or fibre bundle. The LED light source was coupled to a standard laparoscope and performance parameters (power, luminance, colour temperature) compared to a xenon lamp. Although the total illuminance from the endoscope was lower, adjustment of the LEDs' relative intensities enabled contrast enhancement in biological tissue imaging. The LED light engine was also evaluated in a minimally invasive surgery (MIS) box trainer and in vivo during a porcine MIS procedure where it was used to generate 'narrowband' images. Future work using the violet LED could enable photodynamic diagnosis of bladder cancer.

  4. A Primer on Endoscopic Electronic Medical Records

    OpenAIRE

    Atreja, Ashish; Rizk, Maged; Gurland, Brooke

    2010-01-01

    Endoscopic electronic medical record systems (EEMRs) are now increasingly utilized in many endoscopy centers. Modern EEMRs not only support endoscopy report generation, but often include features such as practice management tools, image and video clip management, inventory management, e-faxes to referring physicians, and database support to measure quality and patient outcomes. There are many existing software vendors offering EEMRs, and choosing a software vendor can be time consuming and co...

  5. Reliability in endoscopic diagnosis of portal hypertensive gastropathy

    Science.gov (United States)

    de Macedo, George Fred Soares; Ferreira, Fabio Gonçalves; Ribeiro, Maurício Alves; Szutan, Luiz Arnaldo; Assef, Mauricio Saab; Rossini, Lucio Giovanni Battista

    2013-01-01

    AIM: To analyze reliability among endoscopists in diagnosing portal hypertensive gastropathy (PHG) and to determine which criteria from the most utilized classifications are the most suitable. METHODS: From January to July 2009, in an academic quaternary referral center at Santa Casa of São Paulo Endoscopy Service, Brazil, we performed this single-center prospective study. In this period, we included 100 patients, including 50 sequential patients who had portal hypertension of various etiologies; who were previously diagnosed based on clinical, laboratory and imaging exams; and who presented with esophageal varices. In addition, our study included 50 sequential patients who had dyspeptic symptoms and were referred for upper digestive endoscopy without portal hypertension. All subjects underwent upper digestive endoscopy, and the images of the exam were digitally recorded. Five endoscopists with more than 15 years of experience answered an electronic questionnaire, which included endoscopic criteria from the 3 most commonly used Portal Hypertensive Gastropathy classifications (McCormack, NIEC and Baveno) and the presence of elevated or flat antral erosive gastritis. All five endoscopists were blinded to the patients’ clinical information, and all images of varices were deliberately excluded for the analysis. RESULTS: The three most common etiologies of portal hypertension were schistosomiasis (36%), alcoholic cirrhosis (20%) and viral cirrhosis (14%). Of the 50 patients with portal hypertension, 84% were Child A, 12% were Child B, 4% were Child C, 64% exhibited previous variceal bleeding and 66% were previously endoscopic treated. The endoscopic parameters, presence or absence of mosaic-like pattern, red point lesions and cherry-red spots were associated with high inter-observer reliability and high specificity for diagnosing Portal Hypertensive Gastropathy. Sensitivity, specificity and reliability for the diagnosis of PHG (%) were as follows: mosaic-like pattern

  6. 5-ALA/PpIX fluorescence detection of gastrointestinal neoplasia

    Science.gov (United States)

    Borisova, Ekaterina G.; Vladimirov, Borislav; Terziev, Ivan; Ivanova, Radina; Avramov, Latchezar

    2009-07-01

    In the recent study delta-ALA/PpIX is used as fluorescent marker for dysplasia and tumor detection in esophagus, stomach and colon. ALA is administered per os six to eight (depending on the lesion location) hours before measurements at dose 20mg/kg weight. High-power light-emitting diode at 405 nm is used as an excitation source. Special opto-mechanical device is built for the LED to use the light guide of standard video-endoscopic system. Through endoscopic instrumental channel a fiber is applied to return information about fluorescence to microspectrometer. The fluorescence detected from tumor sites has very complex spectral origins. It consists of autofluorescence, fluorescence from exogenous fluorophores and re-absorption from the chromophores accumulated in the tissue investigated. Spectral features observed during endoscopic investigations could be distinct as the next regions: 450-630 nm region, where tissue autofluorescence is observed; 630-710 nm region, where fluorescence of PpIX is clearly pronounced; 530-580 nm region, where minima in the autofluorescence signal are observed, related to re-absorption of oxy-hemoglobin in this spectral area. Endogenous and exogenous fluorescence spectra are used to develop simple but effective algorithm, based on dimensionless ratio of the signals at 560 and 635 nm, for differentiation of normal/abnormal gastrointestinal tissues. Very good correlation between fluorescence signals and histology examination of the lesions investigated is achieved.

  7. Endoscopic ultrasound features of chronic pancreatitis

    DEFF Research Database (Denmark)

    Rana, Surinder Singh; Vilmann, Peter

    2015-01-01

    As endoscopic ultrasound (EUS) is the most sensitive imaging modality for diagnosing pancreatic disorders, it can demonstrate subtle alterations in the pancreatic parenchymal and ductal structure even before traditional imaging and functional testing demonstrate any abnormality. In spite...... of this fact and abundant literature, the exact role of EUS in the diagnosis of chronic pancreatitis (CP) is still not established. The EUS features to diagnose CP have evolved over a period from a pure qualitative approach to more advanced and complicated scoring systems incorporating multiple parenchymal...... to define the exact role of these criteria. The measurement of strain ratio using quantitative EUS elastography and thus allowing quantification of pancreatic fibrosis seems to be a promising new technique....

  8. Skin Autofluorescence Based Decision Tree in Detection of Impaired Glucose Tolerance and Diabetes

    NARCIS (Netherlands)

    Smit, Andries J.; Smit, Jitske M.; Botterblom, Gijs J.; Mulder, Douwe

    2013-01-01

    Aim: Diabetes (DM) and impaired glucose tolerance (IGT) detection are conventionally based on glycemic criteria. Skin autofluorescence (SAF) is a noninvasive proxy of tissue accumulation of advanced glycation endproducts (AGE) which are considered to be a carrier of glycometabolic memory. We

  9. Selection/extraction of spectral regions for autofluorescence spectra measured in the oral cavity

    NARCIS (Netherlands)

    Skurichina, M; Paclik, P; Duin, RPW; de Veld, D; Sterenborg, HJCM; Witjes, MJH; Roodenburg, JLN; Fred, A; Caelli, T; Duin, RPW; Campilho, A; DeRidder, D

    2004-01-01

    Recently a number of successful algorithms to select/extract discriminative spectral regions was introduced. These methods may be more beneficial than the standard feature selection/extraction methods for spectral classification. In this paper, on the example of autofluorescence spectra measured in

  10. Diagnosis of Acute Appendicitis by Endoscopic Retrograde Appendicitis Therapy (ERAT): Combination of Colonoscopy and Endoscopic Retrograde Appendicography.

    Science.gov (United States)

    Li, Yingchao; Mi, Chen; Li, Weizhi; She, Junjun

    2016-11-01

    Acute appendicitis is the most common abdominal emergency, but the diagnosis of appendicitis remains a challenge. Endoscopic retrograde appendicitis therapy (ERAT) is a new and minimally invasive procedure for the diagnosis and treatment of acute appendicitis. To investigate the diagnostic value of ERAT for acute appendicitis by the combination of colonoscopy and endoscopic retrograde appendicography (ERA). Twenty-one patients with the diagnosis of suspected uncomplicated acute appendicitis who underwent ERAT between November 2014 and January 2015 were included in this study. The main outcomes, imaging findings of acute appendicitis including colonoscopic direct-vision imaging and fluoroscopic ERA imaging, were retrospectively reviewed. Secondary outcomes included mean operative time, mean hospital stay, rate of complication, rate of appendectomy during follow-up period, and other clinical data. The diagnosis of acute appendicitis was established in 20 patients by positive ERA (5 patients) or colonoscopy (1 patient) alone or both (14 patients). The main colonoscopic imaging findings included mucosal inflammation (15/20, 75 %), appendicoliths (14/20, 70 %), and maturation (5/20, 25 %). The key points of ERA for diagnosing acute appendicitis included radiographic changes of appendix (17/20, 85 %), intraluminal appendicoliths (14/20, 70 %), and perforation (1/20, 5 %). Mean operative time of ERAT was 49.7 min, and mean hospital stay was 3.3 days. No patient converted to emergency appendectomy. Perforation occurred in one patient after appendicoliths removal was not severe and did not require invasive procedures. During at least 1-year follow-up period, only one patient underwent laparoscopic appendectomy. ERAT is a valuable procedure of choice providing a precise yield of diagnostic information for patients with suspected acute appendicitis by combination of colonoscopy and ERA.

  11. Endoscopic resection of subepithelial tumors.

    Science.gov (United States)

    Schmidt, Arthur; Bauder, Markus; Riecken, Bettina; Caca, Karel

    2014-12-16

    Management of subepithelial tumors (SETs) remains challenging. Endoscopic ultrasound (EUS) has improved differential diagnosis of these tumors but a definitive diagnosis on EUS findings alone can be achieved in the minority of cases. Complete endoscopic resection may provide a reasonable approach for tissue acquisition and may also be therapeutic in case of malignant lesions. Small SET restricted to the submucosa can be removed with established basic resection techniques. However, resection of SET arising from deeper layers of the gastrointestinal wall requires advanced endoscopic methods and harbours the risk of perforation. Innovative techniques such as submucosal tunneling and full thickness resection have expanded the frontiers of endoscopic therapy in the past years. This review will give an overview about endoscopic resection techniques of SET with a focus on novel methods.

  12. The appearance of the pre-Achilles fat pad after endoscopic calcaneoplasty

    NARCIS (Netherlands)

    Wiegerinck, Johannes I.; Zwiers, Ruben; van Sterkenburg, Maayke N.; Maas, Mario M.; van Dijk, C. Niek

    2015-01-01

    To evaluate whether the imaging features of the retrocalcaneal recess normalize on a conventional radiograph after surgery for retrocalcaneal bursitis and evaluate whether it can be reused if complaints reoccur. Patients who underwent an endoscopic calcaneoplasty at least 2 years before were

  13. Endoscopic Ultrasound in Endocrinology: Imaging of the Adrenals and the Endocrine Pancreas.

    Science.gov (United States)

    Kann, Peter Herbert

    2016-01-01

    Endoscopic ultrasound (EUS) imaging of adrenal glands and its application to diagnostic procedures of adrenal diseases has been reported since 1998. It can be considered a relevant advantage in the field of adrenal diseases. Indeed, EUS allows the detection of adrenal lesions (even very small ones) and their characterization, the assessment of malignancy criteria, the early detection of neoplastic recurrences, the preoperative identification of morphologically healthy parts of the glands, the differentiation of extra-adrenal from adrenal tumors, and of the pathological entities associated with adrenal insufficiency, and the fine-needle aspiration biopsy (EUS-FNA) of suspicious lesions. At the same time, its clinical relevance depends on the experience of the endosonographer. Moreover, EUS is also by far the best and most sensitive imaging technique to detect and assess the follow-up of pancreatic manifestation of MEN1 disease. It furthermore enables the preoperatively localization of insulinomas and critical structures in their neighborhood, and may be relevant in planning surgical strategy. A positive EUS in a case of insulinoma furthermore confirms the endocrine diagnosis, especially considering the differential diagnosis of hypoglycemia factitia by oral antidiabetics. It can be supplemented by EUS-FNA. Again, it has to be considered that EUS may reveal false positive and false negative results, and the quality of the findings largely depends on the endosonographer's skills and experience. The most important technical details together with the advantages and limitations of EUS, and the pathognomonic characteristic of benign and malignant disorders of the adrenals and pancreas are presented here. © 2016 S. Karger AG, Basel.

  14. A new robotic-assisted flexible endoscope with single-hand control: endoscopic submucosal dissection in the ex vivo porcine stomach.

    Science.gov (United States)

    Iwasa, Tsutomu; Nakadate, Ryu; Onogi, Shinya; Okamoto, Yasuharu; Arata, Jumpei; Oguri, Susumu; Ogino, Haruei; Ihara, Eikichi; Ohuchida, Kenoki; Akahoshi, Tomohiko; Ikeda, Tetsuo; Ogawa, Yoshihiro; Hashizume, Makoto

    2018-04-17

    Difficulties in endoscopic operations and therapeutic procedures seem to occur due to the complexity of operating the endoscope dial as well as difficulty in performing synchronized movements with both hands. We developed a prototype robotic-assisted flexible endoscope that can be controlled with a single hand in order to simplify the operation of the endoscope. The aim of this study was to confirm the operability of the robotic-assisted flexible endoscope (RAFE) by performing endoscopic submucosal dissection (ESD). Study 1: ESD was performed manually or with RAFE by an expert endoscopist in ex vivo porcine stomachs; six operations manually and six were performed with RAFE. The procedure time per unit circumferential length/area was calculated, and the results were statistically analyzed. Study 2: We evaluated how smoothly a non-endoscopist can move a RAFE compared to a manual endoscope by assessing the designated movement of the endoscope. Study 1: En bloc resection was achieved by ESD using the RAFE. The procedure time was gradually shortened with increasing experience, and the procedure time of ESD performed with the RAFE was not significantly different from that of ESD performed with a manual endoscope. Study 2: The time for the designated movement of the endoscope was significantly shorter with a RAFE than that with a manual endoscope as for a non-endoscopist. The RAFE that we developed enabled an expert endoscopist to perform the ESD procedure without any problems and allowed a non-endoscopist to control the endoscope more easily and quickly than a manual endoscope. The RAFE is expected to undergo further development.

  15. Lifestyle and clinical determinants of skin autofluorescence in a population-based cohort study

    NARCIS (Netherlands)

    van Waateringe, Robert P; Slagter, Sandra N; van der Klauw, Melanie M; van Vliet-Ostaptchouk, Jana V; Graaff, Reindert; Paterson, Andrew D; Lutgers, Helen L; Wolffenbuttel, Bruce H R

    BACKGROUND: Skin autofluorescence (SAF) is a non-invasive marker of advanced glycation end products (AGEs). In diabetes, higher SAF levels has been positively associated with long-term complications, cardiovascular morbidity and mortality. Because little is known about the factors that influence SAF

  16. Accuracy of endoscopic ultrasonography for diagnosing ulcerative early gastric cancers

    Science.gov (United States)

    Park, Jin-Seok; Kim, Hyungkil; Bang, Byongwook; Kwon, Kyesook; Shin, Youngwoon

    2016-01-01

    Abstract Although endoscopic ultrasonography (EUS) is the first-choice imaging modality for predicting the invasion depth of early gastric cancer (EGC), the prediction accuracy of EUS is significantly decreased when EGC is combined with ulceration. The aim of present study was to compare the accuracy of EUS and conventional endoscopy (CE) for determining the depth of EGC. In addition, the various clinic-pathologic factors affecting the diagnostic accuracy of EUS, with a particular focus on endoscopic ulcer shapes, were evaluated. We retrospectively reviewed data from 236 consecutive patients with ulcerative EGC. All patients underwent EUS for estimating tumor invasion depth, followed by either curative surgery or endoscopic treatment. The diagnostic accuracy of EUS and CE was evaluated by comparing the final histologic result of resected specimen. The correlation between accuracy of EUS and characteristics of EGC (tumor size, histology, location in stomach, tumor invasion depth, and endoscopic ulcer shapes) was analyzed. Endoscopic ulcer shapes were classified into 3 groups: definite ulcer, superficial ulcer, and ill-defined ulcer. The overall accuracy of EUS and CE for predicting the invasion depth in ulcerative EGC was 68.6% and 55.5%, respectively. Of the 236 patients, 36 patients were classified as definite ulcers, 98 were superficial ulcers, and 102 were ill-defined ulcers, In univariate analysis, EUS accuracy was associated with invasion depth (P = 0.023), tumor size (P = 0.034), and endoscopic ulcer shapes (P = 0.001). In multivariate analysis, there is a significant association between superficial ulcer in CE and EUS accuracy (odds ratio: 2.977; 95% confidence interval: 1.255–7.064; P = 0.013). The accuracy of EUS for determining tumor invasion depth in ulcerative EGC was superior to that of CE. In addition, ulcer shape was an important factor that affected EUS accuracy. PMID:27472672

  17. Submucosal tunnel endoscopy: Peroral endoscopic myotomy and peroral endoscopic tumor resection

    Science.gov (United States)

    Eleftheriadis, Nikolas; Inoue, Haruhiro; Ikeda, Haruo; Onimaru, Manabu; Maselli, Roberta; Santi, Grace

    2016-01-01

    Peroral endoscopic myotomy (POEM) is an innovative, minimally invasive, endoscopic treatment for esophageal achalasia and other esophageal motility disorders, emerged from the natural orifice transluminal endoscopic surgery procedures, and since the first human case performed by Inoue in 2008, showed exciting results in international level, with more than 4000 cases globally up to now. POEM showed superior characteristics than the standard 100-year-old surgical or laparoscopic Heller myotomy (LHM), not only for all types of esophageal achalasia [classical (I), vigorous (II), spastic (III), Chicago Classification], but also for advanced sigmoid type achalasia (S1 and S2), failed LHM, or other esophageal motility disorders (diffuse esophageal spasm, nutcracker esophagus or Jackhammer esophagus). POEM starts with a mucosal incision, followed by submucosal tunnel creation crossing the esophagogastric junction (EGJ) and myotomy. Finally the mucosal entry is closed with endoscopic clip placement. POEM permitted relatively free choice of myotomy length and localization. Although it is technically demanding procedure, POEM can be performed safely and achieves very good control of dysphagia and chest pain. Gastroesophageal reflux is the most common troublesome side effect, and is well controllable with proton pump inhibitors. Furthermore, POEM opened the era of submucosal tunnel endoscopy, with many other applications. Based on the same principles with POEM, in combination with new technological developments, such as endoscopic suturing, peroral endoscopic tumor resection (POET), is safely and effectively applied for challenging submucosal esophageal, EGJ and gastric cardia tumors (submucosal tumors), emerged from muscularis propria. POET showed up to know promising results, however, it is restricted to specialized centers. The present article reviews the recent data of POEM and POET and discussed controversial issues that need further study and future perspectives. PMID

  18. Evaluation of the contribution of the renal capsule and cortex to kidney autofluorescence intensity under ultraviolet excitation

    Energy Technology Data Exchange (ETDEWEB)

    Raman, R N; Pivetti, C D; Rubenchik, A M; Matthews, D L; Troppmann, C; Demos, S G

    2008-12-12

    The use of reduced nicotinamide adenine dinucleotide (NADH) fluorescence to gain metabolic information on kidneys in response to an alteration in oxygen availability has previously been experimentally demonstrated, but signal quantification has not to date been addressed. In this work the relative contribution to rat kidney autofluorescence of the capsule vs. cortex under ultraviolet excitation is determined from experimental results obtained using autofluorescence microscopy and a suitable mathematical model. The results allow for a quantitative assessment of the relative contribution of the signal originating in the metabolically active cortex as a function of capsule thickness for different wavelengths.

  19. MEMS-based non-rotatory circumferential scanning optical probe for endoscopic optical coherence tomography

    Science.gov (United States)

    Xu, Yingshun; Singh, Janak; Siang, Teo Hui; Ramakrishna, Kotlanka; Premchandran, C. S.; Sheng, Chen Wei; Kuan, Chuah Tong; Chen, Nanguang; Olivo, Malini C.; Sheppard, Colin J. R.

    2007-07-01

    In this paper, we present a non-rotatory circumferential scanning optical probe integrated with a MEMS scanner for in vivo endoscopic optical coherence tomography (OCT). OCT is an emerging optical imaging technique that allows high resolution cross-sectional imaging of tissue microstructure. To extend its usage to endoscopic applications, a miniaturized optical probe based on Microelectromechanical Systems (MEMS) fabrication techniques is currently desired. A 3D electrothermally actuated micromirror realized using micromachining single crystal silicon (SCS) process highlights its very large angular deflection, about 45 degree, with low driving voltage for safety consideration. The micromirror is integrated with a GRIN lens into a waterproof package which is compatible with requirements for minimally invasive endoscopic procedures. To implement circumferential scanning substantially for diagnosis on certain pathological conditions, such as Barret's esophagus, the micromirror is mounted on 90 degree to optical axis of GRIN lens. 4 Bimorph actuators that are connected to the mirror on one end via supporting beams and springs are selected in this micromirror design. When actuators of the micromirror are driven by 4 channels of sinusoidal waveforms with 90 degree phase differences, beam focused by a GRIN is redirected out of the endoscope by 45 degree tilting mirror plate and achieve circumferential scanning pattern. This novel driving method making full use of very large angular deflection capability of our micromirror is totally different from previously developed or developing micromotor-like rotatory MEMS device for circumferential scanning.

  20. Therapeutic aspects of endoscopic ultrasound

    Science.gov (United States)

    Woodward, Timothy A.

    1999-06-01

    Endoscopic ultrasound (EUS) is a technology that had been used primarily as a passive imaging modality. Recent advances have enabled us to move beyond the use of EUS solely as a staging tool to an interventional device. Current studies suggest that interventional applications of EUS will allow for minimally invasive assessment and therapies in a cost-effective manner. Endoscopic ultrasound with fine needle aspiration (EUS-FNA) has been demonstrated to be a technically feasible, relatively safe method of obtaining cytologic specimens. The clinical utility of EUS- FNA appears to be greatest in the diagnosis and staging of pancreatic cancer and in the nodal staging of gastrointestinal and pulmonary malignancies. In addition, EUS-FNA has demonstrated utility in the sampling pleural and ascitic fluid not generally appreciated or assessable to standard interventions. Interventional applications of EUS include EUS-guided pseudocyst drainage, EUS-guided injection of botulinum toxin in the treatment of achalasia, and EUS- guided celiac plexus neurolysis in the treatment of pancreatic cancer pain. Finally, EUS-guided fine-needle installation is being evaluated, in conjunction with recent bimolecular treatment modalities, as a delivery system in the treatment of certain gastrointestinal tumors.

  1. FLIM-FRET image analysis of tryptophan in prostate cancer cells

    Science.gov (United States)

    Periasamy, Ammasi; Alam, Shagufta R.; Svindrych, Zdenek; Wallrabe, Horst

    2017-07-01

    A region of interest (ROI) based quantitative FLIM-FRET image analysis is developed to quantitate the autofluorescence signals of the essential amino acid tryptophan as a biomarker to investigate the metabolism in prostate cancer cells.

  2. Endoscopic approaches to treatment of achalasia

    Science.gov (United States)

    Friedel, David; Modayil, Rani; Iqbal, Shahzad; Grendell, James H.

    2013-01-01

    Endoscopic therapy for achalasia is directed at disrupting or weakening the lower esophageal sphincter (LES). The two most commonly utilized endoscopic interventions are large balloon pneumatic dilation (PD) and botulinum toxin injection (BTI). These interventions have been extensively scrutinized and compared with each other as well as with surgical disruption (myotomy) of the LES. PD is generally more effective in improving dysphagia in achalasia than BTI, with the latter reserved for infirm older people, and PD may approach treatment results attained with myotomy. However, PD may need to be repeated. Small balloon dilation and endoscopic stent placement for achalasia have only been used in select centers. Per oral endoscopic myotomy is a newer endoscopic modality that will likely change the treatment paradigm for achalasia. It arose from the field of natural orifice transluminal endoscopic surgery and represents a scarless endoscopic approach to Heller myotomy. This is a technique that requires extensive training and preparation and thus there should be rigorous accreditation and monitoring of outcomes to ensure safety and efficacy. PMID:23503707

  3. A Novel Augmented Reality Navigation System for Endoscopic Sinus and Skull Base Surgery: A Feasibility Study

    Science.gov (United States)

    Li, Liang; Yang, Jian; Chu, Yakui; Wu, Wenbo; Xue, Jin; Liang, Ping; Chen, Lei

    2016-01-01

    Objective To verify the reliability and clinical feasibility of a self-developed navigation system based on an augmented reality technique for endoscopic sinus and skull base surgery. Materials and Methods In this study we performed a head phantom and cadaver experiment to determine the display effect and accuracy of our navigational system. We compared cadaver head-based simulated operations, the target registration error, operation time, and National Aeronautics and Space Administration Task Load Index scores of our navigation system to conventional navigation systems. Results The navigation system developed in this study has a novel display mode capable of fusing endoscopic images to three-dimensional (3-D) virtual images. In the cadaver head experiment, the target registration error was 1.28 ± 0.45 mm, which met the accepted standards of a navigation system used for nasal endoscopic surgery. Compared with conventional navigation systems, the new system was more effective in terms of operation time and the mental workload of surgeons, which is especially important for less experienced surgeons. Conclusion The self-developed augmented reality navigation system for endoscopic sinus and skull base surgery appears to have advantages that outweigh those of conventional navigation systems. We conclude that this navigational system will provide rhinologists with more intuitive and more detailed imaging information, thus reducing the judgment time and mental workload of surgeons when performing complex sinus and skull base surgeries. Ultimately, this new navigational system has potential to increase the quality of surgeries. In addition, the augmented reality navigational system could be of interest to junior doctors being trained in endoscopic techniques because it could speed up their learning. However, it should be noted that the navigation system serves as an adjunct to a surgeon’s skills and knowledge, not as a substitute. PMID:26757365

  4. A Novel Augmented Reality Navigation System for Endoscopic Sinus and Skull Base Surgery: A Feasibility Study.

    Directory of Open Access Journals (Sweden)

    Liang Li

    Full Text Available To verify the reliability and clinical feasibility of a self-developed navigation system based on an augmented reality technique for endoscopic sinus and skull base surgery.In this study we performed a head phantom and cadaver experiment to determine the display effect and accuracy of our navigational system. We compared cadaver head-based simulated operations, the target registration error, operation time, and National Aeronautics and Space Administration Task Load Index scores of our navigation system to conventional navigation systems.The navigation system developed in this study has a novel display mode capable of fusing endoscopic images to three-dimensional (3-D virtual images. In the cadaver head experiment, the target registration error was 1.28 ± 0.45 mm, which met the accepted standards of a navigation system used for nasal endoscopic surgery. Compared with conventional navigation systems, the new system was more effective in terms of operation time and the mental workload of surgeons, which is especially important for less experienced surgeons.The self-developed augmented reality navigation system for endoscopic sinus and skull base surgery appears to have advantages that outweigh those of conventional navigation systems. We conclude that this navigational system will provide rhinologists with more intuitive and more detailed imaging information, thus reducing the judgment time and mental workload of surgeons when performing complex sinus and skull base surgeries. Ultimately, this new navigational system has potential to increase the quality of surgeries. In addition, the augmented reality navigational system could be of interest to junior doctors being trained in endoscopic techniques because it could speed up their learning. However, it should be noted that the navigation system serves as an adjunct to a surgeon's skills and knowledge, not as a substitute.

  5. Skin Autofluorescence and Complications of Diabetes : Does Ethnic Background or Skin Color Matter?

    NARCIS (Netherlands)

    Ahdi, Mohamed; Gerdes, Victor E. A.; Graaff, Reindert; Kuipers, Saskia; Smit, Andries J.; Meesters, Eelco W.

    2015-01-01

    Aims: Skin autofluorescence (AF) has been associated with complications of diabetes. We evaluated the influence of skin color and ethnicity on the association between skin AF and the presence of diabetes-related complications. Materials and Methods: In a multiethnic type 2 diabetes cohort we

  6. Photodetection of early cancer by laser-induced fluorescence of a tumor-selective dye: apparatus design and realization

    Science.gov (United States)

    Wagnieres, Georges A.; Depeursinge, Christian D.; Monnier, Philippe; Savary, Jean-Francois; Cornaz, Piet F.; Chatelain, Andre; van den Bergh, Hubert

    1990-07-01

    An apparatus is designed and realized to detect "early" cancer at the surface of the hollow organs in the human body by endoscopic means. The tumor is localized by the laser induced fluorescence of a dye (HPD) which concentrates selectively in the neoplastic tissue after intravenous injection. Fluorescence contrast between the tumor and its normal surroundings is enhanced by subtracting the background autofluorescence which occurs in both types of tissue. This is done by means of 2-color digital images manipulation in real-time. Preliminary clinical tests of the apparatus demonstrated the detection of carcinoma in situ in the esophagus.

  7. [Endoscopic extraction of gallbladder calculi].

    Science.gov (United States)

    Kühner, W; Frimberger, E; Ottenjann, R

    1984-06-29

    Endoscopic extraction of gallbladder stones were performed, as far as we know for the first time, in three patients with combined choledochocystolithiasis. Following endoscopic papillotomy (EPT) and subsequent mechanical lithotripsy of multiple choledochal concrements measuring up to 3 cm the gallbladder stones were successfully extracted with a Dormia basket through the cystic duct. The patients have remained free of complications after the endoscopic intervention.

  8. Endoscopic findings following retroperitoneal pancreas transplantation.

    Science.gov (United States)

    Pinchuk, Alexey V; Dmitriev, Ilya V; Shmarina, Nonna V; Teterin, Yury S; Balkarov, Aslan G; Storozhev, Roman V; Anisimov, Yuri A; Gasanov, Ali M

    2017-07-01

    An evaluation of the efficacy of endoscopic methods for the diagnosis and correction of surgical and immunological complications after retroperitoneal pancreas transplantation. From October 2011 to March 2015, 27 patients underwent simultaneous retroperitoneal pancreas-kidney transplantation (SPKT). Diagnostic oesophagogastroduodenoscopy (EGD) with protocol biopsy of the donor and recipient duodenal mucosa and endoscopic retrograde pancreatography (ERP) were performed to detect possible complications. Endoscopic stenting of the main pancreatic duct with plastic stents and three-stage endoscopic hemostasis were conducted to correct the identified complications. Endoscopic methods showed high efficiency in the timely diagnosis and adequate correction of complications after retroperitoneal pancreas transplantation. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Transanal endoscopic microsurgery versus endoscopic mucosal resection for large rectal adenomas (TREND-study)

    NARCIS (Netherlands)

    F.J.C. van den Broek (Frank); E.J.R. de Graaf (Eelco); M.G.W. Dijkgraaf (Marcel); J.B. Reitsma (Johannes); J. Haringsma (Jelle); R. Timmer (Robin); B.L. Weusten (Bas); M.F. Gerhards (Michael); E.C. Consten (Esther); M.P. Schwartz (Matthijs); M.J. Boom (Maarten); E.J. Derksen (Erik); A.B. Bijnen (Bart); P.H.P. Davids (Paul); C. Hoff (Christiaan); H.M. van Dullemen (Hendrik); G.D.N. Heine (Dimitri); K. van der Linde (Klaas); J.M. Jansen (Jeroen); R.C.H. Mallant-Hent (Rosalie); R. Breumelhof (Ronald); H. Geldof (Han); J.C. Hardwick (James); P. Doornebosch (Pascal); A.C.T.M. Depla (Annekatrien); M.F. Ernst (Miranda); I.P. van Munster (Ivo); I.H.J.T. de Hingh (Ignace); E.J. Schoon (Erik); W.A. Bemelman (Willem); P. Fockens (Paul); E. Dekker (Evelien)

    2009-01-01

    textabstractBackground: Recent non-randomized studies suggest that extended endoscopic mucosal resection (EMR) is equally effective in removing large rectal adenomas as transanal endoscopic microsurgery (TEM). If equally effective, EMR might be a more cost-effective approach as this strategy does

  10. Multimodal Navigation in Endoscopic Transsphenoidal Resection of Pituitary Tumors using Image-based Vascular and Cranial Nerve Segmentation: A Prospective Validation Study

    Science.gov (United States)

    Dolati, Parviz; Eichberg, Daniel; Golby, Alexandra; Zamani, Amir; Laws, Edward

    2016-01-01

    Introduction Transsphenoidal surgery (TSS) is a well-known approach for the treatment of pituitary tumors. However, lateral misdirection and vascular damage, intraoperative CSF leakage, and optic nerve and vascular injuries are all well-known complications, and the risk of adverse events is more likely in less experienced hands. This prospective study was conducted to validate the accuracy of image-based segmentation in localization of neurovascular structures during TSS. Methods Twenty-five patients with pituitary tumors underwent preoperative 3TMRI, which included thin-sectioned 3D space T2, 3D Time of Flight and MPRAGE sequences. Images were reviewed by an expert independent neuroradiologist. Imaging sequences were loaded in BrainLab iPlanNet (16/25 cases) or Stryker (9/25 cases) image guidance platforms for segmentation and pre-operative planning. After patient registration into the neuronavigation system and subsequent surgical exposure, each segmented neural or vascular element was validated by manual placement of the navigation probe on or as close as possible to the target. The audible pulsations of the bilateral ICA were confirmed using a micro-Doppler probe. Results Pre-operative segmentation of the ICA and cavernous sinus matched with the intra-operative endoscopic and micro-Doppler findings in all cases (Dice Similarity Coefficient =1). This information reassured the surgeons with regard to the lateral extent of bone removal at the sellar floor and the limits of lateral exploration. Excellent correspondence between image-based segmentation and the endoscopic view was also evident at the surface of the tumor and at the tumor-normal gland interfaces. This assisted in preventing unnecessary removal of the normal pituitary gland. Image-guidance assisted the surgeons in localizing the optic nerve and chiasm in 64% of the cases and the diaphragma sella in 52% of cases, which helped to determine the limits of upward exploration and to decrease the risk of CSF

  11. Outcomes after endoscopic port surgery for spontaneous intracerebral hematomas.

    Science.gov (United States)

    Ochalski, Pawel; Chivukula, Srinivas; Shin, Samuel; Prevedello, Daniel; Engh, Johnathan

    2014-05-01

    Spontaneous intracerebral hemorrhages (ICHs) cause significant morbidity and mortality. Traditional open surgical management strategies offer limited benefit except for the most superficial hemorrhages in select patients. Recent reports suggest that endoscopic approaches may improve outcomes, particularly for deep subcortical hemorrhages. However, the management of these patients remains controversial. We reviewed our experience using endoscopic port surgery to identify characteristics that may predict acceptable outcomes. We completed a retrospective chart and imaging review of patients who underwent endoscopic port surgery for evacuation of spontaneous ICH at a single center. Data were gathered regarding patient demographics, hemorrhage locations, operative findings, and clinical outcomes. From 2007 to 2011, 18 patients underwent evacuation of spontaneous intracerebral hematomas using an endoscopic port. The mean age in years was 62 years (range, 43-84 years). Six of 18 patients (33%) died before discharge, and 2 others (11%) died after at least 1 month of survival. Of 12 initial survivors, all were discharged to a rehabilitation or nursing facility. Complete hematoma evacuation was achieved in 7 of 18 patients, with the remaining 11 having a partial evacuation. The patients who died (n = 6) before discharge were statistically more likely to have a left-sided hemorrhage, partial evacuation, or older age than the survivors; death at least 1  month after evacuation was additionally associated with greater preoperative hematoma volumes. Our series demonstrates that endoscopic port surgery for acute intracerebral hematoma evacuation has the ability to achieve significant decompression of large and deep-seated hematomas. Patient age, extent of evacuation, laterality, and preoperative hematoma volume appear to influence patient outcome. Most overall outcomes remain poor. Future studies are necessary to determine if surgical evacuation is in fact superior to best

  12. Endoscopic partial medial maxillectomy with mucosal flap for maxillary sinus mucoceles.

    Science.gov (United States)

    Durr, Megan L; Goldberg, Andrew N

    2014-01-01

    To describe a technique of endoscopic medial maxillectomy with mucosal flap for postoperative maxillary sinus mucoceles and to present a case series of subjects who underwent this procedure. This case series includes four subjects with postoperative maxillary sinus mucoceles who underwent resection via endoscopic partial medial maxillectomy with a mucosal flap. We will discuss the clinical presentation, imaging characteristics, operative details, and outcomes. Four subjects are included in this study. The average age at the time of medial maxillectomy was 52 years (range 35-65 years). Three subjects (75%) were female. One subject (25%) had bilateral postoperative maxillary sinus mucoceles. Two subjects (50%) had unilateral right sided mucoceles, and the remaining subject had a unilateral left sided mucocele. All subjects had a history of multiple sinus procedures for chronic sinusitis including Caldwell-Luc procedures ipsilateral to the postoperative mucocele. All subjects underwent endoscopic medial maxillectomy without complication and were symptom free at the last follow up appointment, average 24 months (range 3-71 months) after medial maxillectomy. For postoperative maxillary sinus mucoceles in locations that are difficult to access via the middle meatus antrostomy, we recommend endoscopic medial maxillectomy with mucosal flap. Our preliminary experience with four subjects demonstrates complete resolution of symptoms after this procedure. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Autofluorescence and high-definition optical coherence tomography of retinal artery occlusions

    OpenAIRE

    Mathew, Raeba; Papavasileiou, Evangelia; Sivaprasad, Sobha

    2010-01-01

    Raeba Mathew, Evangelia Papavasileiou, Sobha SivaprasadLaser and Retinal Research Unit, Department of Ophthalmology, King’s College Hospital, Denmark Hill, London, UKBackground: The purpose of this study is to illustrate the fundus autofluorescence and high-definition optical coherence tomography (HD-OCT) features of acute and long-standing retinal artery occlusions.Design: Retrospective case series.Participants: Patients with acute and chronic retinal and cilioretinal artery occlus...

  14. Transanal endoscopic microsurgery versus endoscopic mucosal resection for large rectal adenomas (TREND-study)

    NARCIS (Netherlands)

    van den Broek, Frank J. C.; de Graaf, Eelco J. R.; Dijkgraaf, Marcel G. W.; Haringsma, Jelle; Timmer, Robin; Weusten, Bas L. A. M.; Gerhards, Michael F.; Consten, Esther C. J.; Schwartz, Matthijs P.; Boom, Maarten J.; Derksen, Erik J.; Bijnen, A. Bart; Davids, Paul H. P.; Hoff, Christiaan; van Dullemen, Hendrik M.; Heine, G. Dimitri N.; van der Linde, Klaas; Jansen, Jeroen M.; Mallant-Hent, Rosalie C. H.; Breumelhof, Ronald; Geldof, Han; Hardwick, James C. H.; Doornebosch, Pascal G.; Depla, Annekatrien C. T. M.; Ernst, Miranda F.; van Munster, Ivo P.; de Hingh, Ignace H. J. T.; Schoon, Erik J.; Bemelman, Willem A.; Fockens, Paul; Dekker, Evelien; Reitsma, J.

    2009-01-01

    Background: Recent non-randomized studies suggest that extended endoscopic mucosal resection (EMR) is equally effective in removing large rectal adenomas as transanal endoscopic microsurgery (TEM). If equally effective, EMR might be a more cost-effective approach as this strategy does not require

  15. [Endoscopic full-thickness resection].

    Science.gov (United States)

    Meier, B; Schmidt, A; Caca, K

    2016-08-01

    Conventional endoscopic resection techniques such as endoscopic mucosal resection (EMR) or endoscopic submucosal dissection (ESD) are powerful tools for the treatment of gastrointestinal (GI) neoplasms. However, those techniques are limited to the superficial layers of the GI wall (mucosa and submucosa). Lesions without lifting sign (usually arising from deeper layers) or lesions in difficult anatomic positions (appendix, diverticulum) are difficult - if not impossible - to resect using conventional techniques, due to the increased risk of complications. For larger lesions (>2 cm), ESD appears to be superior to the conventional techniques because of the en bloc resection, but the procedure is technically challenging, time consuming, and associated with complications even in experienced hands. Since the development of the over-the-scope clips (OTSC), complications like bleeding or perforation can be endoscopically better managed. In recent years, different endoscopic full-thickness resection techniques came to the focus of interventional endoscopy. Since September 2014, the full-thickness resection device (FTRD) has the CE marking in Europe for full-thickness resection in the lower GI tract. Technically the device is based on the OTSC system and combines OTSC application and snare polypectomy in one step. This study shows all full-thickness resection techniques currently available, but clearly focuses on the experience with the FTRD in the lower GI tract.

  16. Skin autofluorescence is increased in patients with carotid artery stenosis and peripheral artery disease

    NARCIS (Netherlands)

    Noordzij, Marjon J.; Lefrandt, Joop D.; Loeffen, Erik A. H.; Saleem, Ben R.; Meerwaldt, Robbert; Lutgers, Helen L.; Smit, Andries J.; Zeebregts, Clark J.

    Advanced glycation end products (AGEs) have a pivotal role in atherosclerosis. We evaluated skin autofluorescence (SAF), a non-invasive measurement of tissue AGE accumulation, in patients with carotid artery stenosis with and without coexisting peripheral artery occlusive disease (PAOD). SAF was

  17. Folate receptor overexpression can be visualized in real time during pituitary adenoma endoscopic transsphenoidal surgery with near-infrared imaging.

    Science.gov (United States)

    Lee, John Y K; Cho, Steve S; Zeh, Ryan; Pierce, John T; Martinez-Lage, Maria; Adappa, Nithin D; Palmer, James N; Newman, Jason G; Learned, Kim O; White, Caitlin; Kharlip, Julia; Snyder, Peter; Low, Philip S; Singhal, Sunil; Grady, M Sean

    2017-08-25

    OBJECTIVE Pituitary adenomas account for approximately 10% of intracranial tumors and have an estimated prevalence of 15%-20% in the general US population. Resection is the primary treatment for pituitary adenomas, and the transsphenoidal approach remains the most common. The greatest challenge with pituitary adenomas is that 20% of patients develop tumor recurrence. Current approaches to reduce recurrence, such as intraoperative MRI, are costly, associated with high false-positive rates, and not recommended. Pituitary adenomas are known to overexpress folate receptor alpha (FRα), and it was hypothesized that OTL38, a folate analog conjugated to a near-infrared (NIR) fluorescent dye, could provide real-time intraoperative visual contrast of the tumor versus the surrounding nonneoplastic tissues. The preliminary results of this novel clinical trial are presented. METHODS Nineteen adult patients who presented with pituitary adenoma were enrolled. Patients were infused with OTL38 2-4 hours prior to surgery. A 4-mm endoscope with both visible and NIR light capabilities was used to visualize the pituitary adenoma and its margins in real time during surgery. The signal-to-background ratio (SBR) was recorded for each tumor and surrounding tissues at various endoscope-to-sella distances. Immunohistochemical analysis was performed to assess the FRα expression levels in all specimens and classify patients as having either high or low FRα expression. RESULTS Data from 15 patients (4 with null cell adenomas, 1 clinically silent gonadotroph, 1 totally silent somatotroph, 5 with a corticotroph, 3 with somatotrophs, and 1 somatocorticotroph) were analyzed in this preliminary analysis. Four patients were excluded for technical considerations. Intraoperative NIR imaging delineated the main tumors in all 15 patients with an average SBR of 1.9 ± 0.70. The FRα expression level of the adenomas and endoscope-to-sella distance had statistically significant impacts on the fluorescent

  18. Cholangiocarcinoma in Magnetic Resonance Cholangiopancreatography and Fascioliasis in Endoscopic Ultrasonography

    Directory of Open Access Journals (Sweden)

    Amir Houshang Mohammad Alizadeh

    2011-10-01

    Full Text Available Fascioliasis is a worldwide zoonotic infection with Fasciola hepatica and Fasciola gigantica. The zoonoses are particularly endemic in sheep-raising countries and are also endemic in Iran. Typical symptoms that may be associated with fascioliasis can be divided by phases of the disease, including the acute or liver phase, the chronic or biliary phase, and ectopic or pharyngeal fascioliasis. Cholestatic symptoms may be absent, and in some cases diagnosis and treatment may be preceded by a long period of abdominal pain, eosinophilia and vague gastrointestinal symptoms. We report a case with epigastric and upper quadrant abdominal pain for the last 4 years, with imaging suggesting cholangiocarcinoma. Considering a new concept of endoscopic ultrasonography, at last F. hepatica was extracted with endoscopic retrograde cholangiography.

  19. Endoscopic full-thickness resection: Current status.

    Science.gov (United States)

    Schmidt, Arthur; Meier, Benjamin; Caca, Karel

    2015-08-21

    Conventional endoscopic resection techniques such as endoscopic mucosal resection or endoscopic submucosal dissection are powerful tools for treatment of gastrointestinal neoplasms. However, those techniques are restricted to superficial layers of the gastrointestinal wall. Endoscopic full-thickness resection (EFTR) is an evolving technique, which is just about to enter clinical routine. It is not only a powerful tool for diagnostic tissue acquisition but also has the potential to spare surgical therapy in selected patients. This review will give an overview about current EFTR techniques and devices.

  20. Outcomes After Conservative, Endoscopic, and Surgical Treatment of Groove Pancreatitis: A Systematic Review.

    Science.gov (United States)

    Kager, Liesbeth M; Lekkerkerker, Selma J; Arvanitakis, Marianna; Delhaye, Myriam; Fockens, Paul; Boermeester, Marja A; van Hooft, Jeanin E; Besselink, Marc G

    2017-09-01

    Groove pancreatitis (GP) is a focal form of chronic pancreatitis affecting the paraduodenal groove area, for which consensus on diagnosis and management is lacking. We performed a systematic review of the literature to determine patient characteristics and imaging features of GP and to evaluate clinical outcomes after treatment. Eight studies were included reporting on 335 GP patients with a median age of 47 years (range, 34 to 64 y), with 90% male, 87% smokers, and 87% alcohol consumption, and 47 months (range, 15 to 122 mo) of follow-up. Most patients presented with abdominal pain (91%) and/or weight loss (78%). Imaging frequently showed cystic lesions (91%) and duodenal stenosis (60%).Final treatment was conservative (eg, pain medication) in 29% of patients. Endoscopic treatment (eg, pseudocyst drainage) was applied in 19% of patients-34% of these patients were subsequently referred for surgery. Overall, 59% of patients were treated surgically (eg, pancreatoduodenectomy). Complete symptom relief was observed in 50% of patients who were treated conservatively, 57% who underwent endoscopic treatment, and 79% who underwent surgery. GP is associated with male gender, smoking, and alcohol consumption. The vast majority of patients presents with abdominal pain and with cystic lesions on imaging. Although surgical treatment seems to be the most effective, both conservative and endoscopic treatment are successful in about half of patients. A stepwise treatment algorithm starting with the least invasive treatment options seems advisable.

  1. Novel methods for endoscopic training.

    Science.gov (United States)

    Gessner, C E; Jowell, P S; Baillie, J

    1995-04-01

    The development of past, present, and future endoscopic training methods is described. A historical perspective of endoscopy training guidelines and devices is used to demonstrate support for the use of novel endoscopic training techniques. Computer simulation of endoscopy, interactive learning, and virtual reality applications in endoscopy and surgery are reviewed. The goals of endoscopic simulation and challenges facing investigators in this field are discussed, with an emphasis on current and future research.

  2. Combined transnasal and transoral endoscopic approach to a transsphenoidal encephalocele in an infant.

    Science.gov (United States)

    Tan, Sien Hui; Mun, Kein Seong; Chandran, Patricia Ann; Manuel, Anura Michelle; Prepageran, Narayanan; Waran, Vicknes; Ganesan, Dharmendra

    2015-07-01

    This paper reports an unusual case of a transsphenoidal encephalocele and discusses our experience with a minimally invasive management. To the best of our knowledge, we present the first case of a combined endoscopic transnasal and transoral approach to a transsphenoidal encephalocele in an infant. A 17-day-old boy, who was referred for further assessment of upper airway obstruction, presented with respiratory distress and feeding difficulties. Bronchoscopy and imaging revealed a transsphenoidal encephalocele. At the age of 48 days, he underwent a combined endoscopic transnasal and transoral excision of the nasal component of the encephalocele. This approach, with the aid of neuronavigation, allows good demarcation of the extra-cranial neck of the transsphenoidal encephalocele. We were able to cauterize and carefully dissect the sac prior to excision. The defect of the neck was clearly visualized, and Valsalva manoeuvre was performed to exclude any CSF leak. As the defect was small, it was allowed to heal by secondary intention. The patient's recovery was uneventful, and he tolerated full feeds orally on day 2. Postoperative imaging demonstrated no evidence of recurrence of the nasal encephalocele. Endoscopic follow-up showed good healing of the mucosa and no cerebrospinal fluid leak. The surgical management of transsphenoidal encephalocele in neonates and infants is challenging. We describe a safe technique with low morbidity in managing such a condition. The combined endoscopic transnasal and transoral approach with neuronavigation is a minimally invasive, safe and feasible alternative, even for children below 1 year of age.

  3. Endoscopic medial maxillectomy breaking new frontiers.

    Science.gov (United States)

    Mohanty, Sanjeev; Gopinath, M

    2013-07-01

    Endoscopy has changed the perspective of rhinologist towards the nose. It has revolutionised the surgical management of sinonasal disorders. Sinus surgeries were the first to get the benefit of endoscope. Gradually the domain of endoscopic surgery extended to the management of sino nasal tumours. Traditionally medial maxillectomy was performed through lateral rhinotomy or mid facial degloving approach. Endoscopic medial maxillectomy has been advocated by a number of authors in the management of benign sino-nasal tumours. We present our experience of endoscopic medial maxillectomy in the management of sinonasal pathologies.

  4. Endoscopic management of bleeding peptic ulcers

    International Nuclear Information System (INIS)

    Farooqi, J.I.; Farooqi, R.J.

    2001-01-01

    Peptic ulcers account for more than half of the cases of non variceal upper gastrointestinal (GI) bleeding and therefore, are the focus of most of the methods of endoscopic hemostasis. Surgical intervention is now largely reserved for patients in whom endoscopic hemostasis has failed. A variety of endoscopic techniques have been employed to stop bleeding and reduce the risk of rebleeding, with no major differences in outcome between these methods. These include injection therapy, fibrin injection, heater probe, mono polar electrocautery, bipolar electrocautery, lasers and mechanical hemo clipping. The most important factor in determining outcome after gastrointestinal bleeding is rebleeding or persistent bleeding. The endoscopic appearance of an ulcer, however, provides the most useful prognostic information for bleeding. Recurrent bleeding after initial endoscopic hemostasis occurs in 15-20% of patients with a bleeding peptic ulcer. The best approach to these patients remains controversial; the current options are repeat endoscopic therapy with the same or a different technique, emergency surgery or semi elective surgery after repeat endoscopic hemostasis. The combination of epinephrine injection with thermal coagulation may be more effective than epinephrine injection alone. Newer modalities such as fibrin injection or the application of hemo clips appear promising and comparative studies are awaited. (author)

  5. Per-oral endoscopic myotomy: Major advance in achalasia treatment and in endoscopic surgery

    Science.gov (United States)

    Friedel, David; Modayil, Rani; Stavropoulos, Stavros N

    2014-01-01

    Per-oral endoscopic myotomy (POEM) represents a natural orifice endoscopic surgery (NOTES) approach to laparoscopy Heller myotomy (LHM). POEM is arguably the most successful clinical application of NOTES. The growth of POEM from a single center in 2008 to approximately 60 centers worldwide in 2014 with several thousand procedures having been performed attests to the success of POEM. Initial efficacy, safety and acid reflux data suggest at least equivalence of POEM to LHM, the previous gold standard for achalasia therapy. Adjunctive techniques used in the West include impedance planimetry for real-time intraprocedural luminal assessment and endoscopic suturing for challenging mucosal defect closures during POEM. The impact of POEM extends beyond the realm of esophageal motility disorders as it is rapidly popularizing endoscopic submucosal dissection in the West and spawning offshoots that use the submucosal tunnel technique for a host of new indications ranging from resection of tumors to pyloromyotomy for gastroparesis. PMID:25548473

  6. Endoscopic tissue diagnosis of cholangiocarcinoma.

    LENUS (Irish Health Repository)

    Harewood, Gavin C

    2008-09-01

    The extremely poor outcome in patients with cholangiocarcinoma, in large part, reflects the late presentation of these tumors and the challenging nature of establishing a tissue diagnosis. Establishing a diagnosis of cholangiocarcinoma requires obtaining evidence of malignancy from sampling of the epithelium of the biliary tract, which has proven to be challenging. Although endoscopic ultrasound-guided fine needle aspiration performs slightly better than endoscopic retrograde cholangiopancreatography in diagnosing cholangiocarcinoma, both endoscopic approaches demonstrate disappointing performance characteristics.

  7. Endoscopic repair of transsellar transsphenoidal meningoencephalocele; case report and review of approaches

    Directory of Open Access Journals (Sweden)

    Maryam Jalessi, M.D.

    2015-06-01

    Full Text Available We present an extremely rare case of transsellar transsphenoidal meningoencephalocele in a 36-year-old woman with pituitary dwarfism complaining of nasal obstruction. Imaging studies showed a bony defect in the sellar floor and sphenoid sinus with huge nasopharyngeal mass and 3rd ventricle involvement. Using endoscopic endonasal approach the sac was partially removed and the defect was reconstructed with fat and fascial graft, and buttressed with titanium mesh and septal flap. Visual field improvement was noticed post-operatively and no complication was encountered during follow-up. So, endoscopic endonasal approach with partial resection of the sac is a safe and effective treatment for this disease

  8. Papillary Ependymoma WHO Grade II of the Aqueduct Treated by Endoscopic Tumor Resection

    Directory of Open Access Journals (Sweden)

    Andreas M. Stark

    2009-01-01

    Full Text Available Papillary ependymoma is a rare tumor that may be located along the ventricular walls or within the spinal cord. We report the case of a 54-year-old patient with a papillary ependymoma WHO grade II arising at the entrance of the aqueduct. The tumor caused hydrocephalus. The tumor was completely removed via a right-sided endoscopic approach with restoration of the aqueduct. The free cerebrospinal fluid passage through the aqueduct was not only visualized by endoscopy but also controlled by intraoperative high-field magnetic resonance imaging. Therefore, an additional endoscopic third ventriculostomy was unneccessary.

  9. TU-AB-202-12: A Novel Method to Map Endoscopic Video to CT for Treatment Planning and Toxicity Analysis in Radiation Therapy

    International Nuclear Information System (INIS)

    Ingram, W; Yang, J; Beadle, B; Wendt, R; Rao, A; Court, L

    2016-01-01

    Purpose: Endoscopic examinations are routine procedures for head-and-neck cancer patients. Our goal is to develop a method to map the recorded video to CT, providing valuable information for radiotherapy treatment planning and toxicity analysis. Methods: We map video frames to CT via virtual endoscopic images rendered at the real endoscope’s CT-space coordinates. We developed two complementary methods to find these coordinates by maximizing real-to-virtual image similarity:(1)Endoscope Tracking: moves the virtual endoscope frame-by-frame until the desired frame is reached. Utilizes prior knowledge of endoscope coordinates, but sensitive to local optima. (2)Location Search: moves the virtual endoscope along possible paths through the volume to find the desired frame. More robust, but more computationally expensive. We tested these methods on clay phantoms with embedded markers for point mapping and protruding bolus material for contour mapping, and we assessed them qualitatively on three patient exams. For mapped points we calculated 3D-distance errors, and for mapped contours we calculated mean absolute distances (MAD) from CT contours. Results: In phantoms, Endoscope Tracking had average point error=0.66±0.50cm and average bolus MAD=0.74±0.37cm for the first 80% of each video. After that the virtual endoscope got lost, increasing these values to 4.73±1.69cm and 4.06±0.30cm. Location Search had point error=0.49±0.44cm and MAD=0.53±0.28cm. Point errors were larger where the endoscope viewed the surface at shallow angles<10 degrees (1.38±0.62cm and 1.22±0.69cm for Endoscope Tracking and Location Search, respectively). In patients, Endoscope Tracking did not make it past the nasal cavity. However, Location Search found coordinates near the correct location for 70% of test frames. Its performance was best near the epiglottis and in the nasal cavity. Conclusion: Location Search is a robust and accurate technique to map endoscopic video to CT. Endoscope

  10. Quantitative fundus autofluorescence in mice: correlation with HPLC quantitation of RPE lipofuscin and measurement of retina outer nuclear layer thickness.

    Science.gov (United States)

    Sparrow, Janet R; Blonska, Anna; Flynn, Erin; Duncker, Tobias; Greenberg, Jonathan P; Secondi, Roberta; Ueda, Keiko; Delori, François C

    2013-04-17

    Our study was conducted to establish procedures and protocols for quantitative autofluorescence (qAF) measurements in mice, and to report changes in qAF, A2E bisretinoid concentration, and outer nuclear layer (ONL) thickness in mice of different genotypes and age. Fundus autofluorescence (AF) images (55° lens, 488 nm excitation) were acquired in albino Abca4(-/-), Abca4(+/-), and Abca4(+/+) mice (ages 2-12 months) with a confocal scanning laser ophthalmoscope (cSLO). Gray levels (GLs) in each image were calibrated to an internal fluorescence reference. The bisretinoid A2E was measured by quantitative high performance liquid chromatography (HPLC). Histometric analysis of ONL thicknesses was performed. The Bland-Altman coefficient of repeatability (95% confidence interval) was ±18% for between-session qAF measurements. Mean qAF values increased with age (2-12 months) in all groups of mice. qAF was approximately 2-fold higher in Abca4(-/-) mice than in Abca4(+/+) mice and approximately 20% higher in heterozygous mice. HPLC measurements of the lipofuscin fluorophore A2E also revealed age-associated increases, and the fold difference between Abca4(-/-) and wild-type mice was more pronounced (approximately 3-4-fold) than measurable by qAF. Moreover, A2E levels declined after 8 months of age, a change not observed with qAF. The decline in A2E levels in the Abca4(-/-) mice corresponded to reduced photoreceptor cell viability as reflected in ONL thinning beginning at 8 months of age. The qAF method enables measurement of in vivo lipofuscin and the detection of genotype and age-associated differences. The use of this approach has the potential to aid in understanding retinal disease processes and will facilitate preclinical studies.

  11. Current Status of Peroral Endoscopic Myotomy

    Science.gov (United States)

    Cho, Young Kwan; Kim, Seong Hwan

    2018-01-01

    Peroral endoscopic myotomy (POEM) has been established as an optional treatment for achalasia. POEM is an endoluminal procedure that involves dissection of esophageal muscle fibers followed by submucosal tunneling. Inoue first attempted to use POEM for the treatment of achalasia in humans. Expanded indications of POEM include classic indications such as type I, type II, type III achalasia, failed prior treatments, including Botulinum toxin injection, endoscopic balloon dilation, laparoscopic Heller myotomy, and hypertensive motor disorders such as diffuse esophageal spasm, jackhammer esophagus. Contraindications include prior radiation therapy to the esophagus and prior extensive esophageal mucosal resection/ablation involving the POEM field. Most of the complications are minor and self-limited and can be managed conservatively. As POEM emerged as the main treatment for achalasia, various adaptations to tunnel endoscopic surgery have been attempted. Tunnel endoscopic surgery includes POEM, peroral endoscopic tumor resection, gastric peroral endoscopic pyloromyotomy. POEM has been widely accepted as a treatment for all types of achalasia, even for specific cases such as achalasia with failed prior treatments, and hypertensive motor disorders. PMID:29397656

  12. Current Status of Peroral Endoscopic Myotomy.

    Science.gov (United States)

    Cho, Young Kwan; Kim, Seong Hwan

    2018-01-01

    Peroral endoscopic myotomy (POEM) has been established as an optional treatment for achalasia. POEM is an endoluminal procedure that involves dissection of esophageal muscle fibers followed by submucosal tunneling. Inoue first attempted to use POEM for the treatment of achalasia in humans. Expanded indications of POEM include classic indications such as type I, type II, type III achalasia, failed prior treatments, including Botulinum toxin injection, endoscopic balloon dilation, laparoscopic Heller myotomy, and hypertensive motor disorders such as diffuse esophageal spasm, jackhammer esophagus. Contraindications include prior radiation therapy to the esophagus and prior extensive esophageal mucosal resection/ablation involving the POEM field. Most of the complications are minor and self-limited and can be managed conservatively. As POEM emerged as the main treatment for achalasia, various adaptations to tunnel endoscopic surgery have been attempted. Tunnel endoscopic surgery includes POEM, peroral endoscopic tumor resection, gastric peroral endoscopic pyloromyotomy. POEM has been widely accepted as a treatment for all types of achalasia, even for specific cases such as achalasia with failed prior treatments, and hypertensive motor disorders.

  13. Current Status of Peroral Endoscopic Myotomy

    Directory of Open Access Journals (Sweden)

    Young Kwan Cho

    2018-01-01

    Full Text Available Peroral endoscopic myotomy (POEM has been established as an optional treatment for achalasia. POEM is an endoluminal procedure that involves dissection of esophageal muscle fibers followed by submucosal tunneling. Inoue first attempted to use POEM for the treatment of achalasia in humans. Expanded indications of POEM include classic indications such as type I, type II, type III achalasia, failed prior treatments, including Botulinum toxin injection, endoscopic balloon dilation, laparoscopic Heller myotomy, and hypertensive motor disorders such as diffuse esophageal spasm, jackhammer esophagus. Contraindications include prior radiation therapy to the esophagus and prior extensive esophageal mucosal resection/ablation involving the POEM field. Most of the complications are minor and self-limited and can be managed conservatively. As POEM emerged as the main treatment for achalasia, various adaptations to tunnel endoscopic surgery have been attempted. Tunnel endoscopic surgery includes POEM, peroral endoscopic tumor resection, gastric peroral endoscopic pyloromyotomy. POEM has been widely accepted as a treatment for all types of achalasia, even for specific cases such as achalasia with failed prior treatments, and hypertensive motor disorders.

  14. Diagnosis of basal cell carcinoma by two photon excited fluorescence combined with lifetime imaging

    Science.gov (United States)

    Fan, Shunping; Peng, Xiao; Liu, Lixin; Liu, Shaoxiong; Lu, Yuan; Qu, Junle

    2014-02-01

    Basal cell carcinoma (BCC) is the most common type of human skin cancer. The traditional diagnostic procedure of BCC is histological examination with haematoxylin and eosin staining of the tissue biopsy. In order to reduce complexity of the diagnosis procedure, a number of noninvasive optical methods have been applied in skin examination, for example, multiphoton tomography (MPT) and fluorescence lifetime imaging microscopy (FLIM). In this study, we explored two-photon optical tomography of human skin specimens using two-photon excited autofluorescence imaging and FLIM. There are a number of naturally endogenous fluorophores in skin sample, such as keratin, melanin, collagen, elastin, flavin and porphyrin. Confocal microscopy was used to obtain structures of the sample. Properties of epidermic and cancer cells were characterized by fluorescence emission spectra, as well as fluorescence lifetime imaging. Our results show that two-photon autofluorescence lifetime imaging can provide accurate optical biopsies with subcellular resolution and is potentially a quantitative optical diagnostic method in skin cancer diagnosis.

  15. Association of age and macular pigment optical density using dual-wavelength autofluorescence imaging.

    Science.gov (United States)

    Lima, Verônica Castro; Rosen, Richard B; Prata, Tiago Santos; Dorairaj, Syril; Spielberg, Leigh; Maia, Mauricio; Sallum, Juliana M

    2013-01-01

    Several lines of evidence suggest that macular pigment may play a protective role against age-related macular degeneration, but the influence of age on macular pigment density levels remains unclear. This study was designed to investigate the relationship between age and the normal distribution of macular pigment optical density (MPOD) values surrounding the fovea. Consecutive healthy subjects with no evidence of ocular disease were enrolled in this study. After inclusion, MPOD values were measured at specific eccentricities (0.5, 1, and 2 degrees) from the foveal center using a dual-wavelength autofluorescence method employing a modified confocal scanning laser ophthalmoscope. Whenever both eyes were eligible, one was randomly selected for analysis. The correlation between age and MPOD values was investigated using regression analysis. Thirty subjects (30 eyes) were included (mean age 48.6 ± 16.4 [range 23-77] years). Significant differences were found between MPOD values measured at 0.5, 1, and 2 degrees from the center of the fovea (0.49 ± 0.12 density units, 0.37 ± 0.11 density units, and 0.13 ± 0.05 density units, respectively, P < 0.05). Significant correlations between age and MPOD values at 0.5 and 1 degree were found (P ≤ 0.02). Values measured at 2 degrees did not correlate significantly with age (P = 0.06). In healthy subjects, MPOD values were highest near the foveal center. These values appeared to increase during adulthood (peak at 45-50 years), followed by a gradual reduction after 60 years of age.

  16. Design and implementation of a sensitive high-resolution nonlinear spectral imaging microscope

    NARCIS (Netherlands)

    Palero, Jonathan A.; Latouche, Gwendal; de Bruijn, Henriëtte S.; van der Ploeg van den Heuvel, Angélique; Sterenborg, Henricus J. C. M.; Gerritsen, Hans C.

    2008-01-01

    Live tissue nonlinear microscopy based on multiphoton autofluorescence and second harmonic emission originating from endogenous fluorophores and noncentrosymmetric-structured proteins is rapidly gaining interest in biomedical applications. The advantage of this technique includes high imaging

  17. Endoscopic resection of cavernoma of foramen of Monro in a patient with familial multiple cavernomatosis.

    Science.gov (United States)

    Prat, Ricardo; Galeano, Inmaculada

    2008-09-01

    Intraventricular cavernomas are extremely infrequent and only 11 cases of cavernous hemangioma to occur at the foramen of Monro have been reported in the literature. This 56 years old patient was admitted with progressive and intractable headache of 10 days of evolution. He was known to suffer familial multiple cavernomatosis. Magnetic resonance imaging (MRI), revealed obstructive hydrocephalus due to a cavernoma located in the area of the left foramen of Monro. Under neuronavigation guidance, complete endoscopic resection of the cavernoma was performed and normal ventricular size achieved. The patient experienced transient recent memory loss that resolved within a month after surgery. In the literature attempted endoscopic resection is reported to be abandoned due to bleeding and ineffectiveness of piecemeal endoscopic resection. In this case, the multiplicity of the lesions made it advisable to resect the lesion endoscopically, to avoid an open procedure in a patient with multiple potentially surgical lesions. Endoscopic resection was uneventful with easy control of bleeding with irrigation, suction, and bipolar coagulation despite dense vascular appearance of the lesion. During the procedure, precise visualization of the vascular structures around the foramen of Monro allowed complete resection with satisfactory control of the instruments. To the best of the authors' knowledge, this is the first published cavernoma of foramen of Monro successfully resected using an endoscopic approach.

  18. Design of signal reception and processing system of embedded ultrasonic endoscope

    Science.gov (United States)

    Li, Ming; Yu, Feng; Zhang, Ruiqiang; Li, Yan; Chen, Xiaodong; Yu, Daoyin

    2009-11-01

    Embedded Ultrasonic Endoscope, based on embedded microprocessor and embedded real-time operating system, sends a micro ultrasonic probe into coelom through the biopsy channel of the Electronic Endoscope to get the fault histology features of digestive organs by rotary scanning, and acquires the pictures of the alimentary canal mucosal surface. At the same time, ultrasonic signals are processed by signal reception and processing system, forming images of the full histology of the digestive organs. Signal Reception and Processing System is an important component of Embedded Ultrasonic Endoscope. However, the traditional design, using multi-level amplifiers and special digital processing circuits to implement signal reception and processing, is no longer satisfying the standards of high-performance, miniaturization and low power requirements that embedded system requires, and as a result of the high noise that multi-level amplifier brought, the extraction of small signal becomes hard. Therefore, this paper presents a method of signal reception and processing based on double variable gain amplifier and FPGA, increasing the flexibility and dynamic range of the Signal Reception and Processing System, improving system noise level, and reducing power consumption. Finally, we set up the embedded experiment system, using a transducer with the center frequency of 8MHz to scan membrane samples, and display the image of ultrasonic echo reflected by each layer of membrane, with a frame rate of 5Hz, verifying the correctness of the system.

  19. Transoral endoscopic esophageal myotomy based on esophageal function testing in a survival porcine model.

    Science.gov (United States)

    Perretta, Silvana; Dallemagne, Bernard; Donatelli, Gianfranco; Diemunsch, Pierre; Marescaux, Jacques

    2011-01-01

    The most effective treatment of achalasia is Heller myotomy. To explore a submucosal endoscopic myotomy technique tailored on esophageal physiology testing and to compare it with the open technique. Prospective acute and survival comparative study in pigs (n = 12; 35 kg). University animal research center. Eight acute-4 open and 4 endoscopic-myotomies followed by 4 survival endoscopic procedures. Preoperative and postoperative manometry; esophagogastric junction (EGJ) distensibility before and after selective division of muscular fibers at the EGJ and after the myotomy was prolonged to a standard length by using the EndoFLIP Functional Lumen Imaging Probe (Crospon, Galway, Ireland). All procedures were successful, with no intraoperative and postoperative complications. In the survival group, the animals recovered promptly from surgery. Postoperative manometry demonstrated a 50% drop in mean lower esophageal sphincter pressure (LESp) in the endoscopic group (mean preoperative LESp, 22.2 ± 3.3 mm Hg; mean postoperative LESp, 11.34 ± 2.7 mm Hg; P open procedure group (mean preoperative LESp, 24.2 ± 3.2 mm Hg; mean postoperative LESp, 7.4 ± 4 mm Hg; P myotomy is feasible and safe. The lack of a significant difference in EGJ distensibility between the open and endoscopic procedure is very appealing. Were it to be perfected in a human population, this endoscopic approach could suggest a new strategy in the treatment of selected achalasia patients. Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  20. An inter-observer agreement study of autofluorescence endoscopy in Barrett's esophagus among expert and non-expert endoscopists.

    Science.gov (United States)

    Mannath, J; Subramanian, V; Telakis, E; Lau, K; Ramappa, V; Wireko, M; Kaye, P V; Ragunath, K

    2013-02-01

    Autofluorescence imaging (AFI), which is a "red flag" technique during Barrett's surveillance, is associated with significant false positive results. The aim of this study was to assess the inter-observer agreement (IOA) in identifying AFI-positive lesions and to assess the overall accuracy of AFI. Anonymized AFI and high resolution white light (HRE) images were prospectively collected. The AFI images were presented in random order, followed by corresponding AFI + HRE images. Three AFI experts and 3 AFI non-experts scored images after a training presentation. The IOA was calculated using kappa and accuracy was calculated with histology as gold standard. Seventy-four sets of images were prospectively collected from 63 patients (48 males, mean age 69 years). The IOA for number of AF positive lesions was fair when AFI images were presented. This improved to moderate with corresponding AFI and HRE images [experts 0.57 (0.44-0.70), non-experts 0.47 (0.35-0.62)]. The IOA for the site of AF lesion was moderate for experts and fair for non-experts using AF images, which improved to substantial for experts [κ = 0.62 (0.50-0.72)] but remained at fair for non-experts [κ = 0.28 (0.18-0.37)] with AFI + HRE. Among experts, the accuracy of identifying dysplasia was 0.76 (0.7-0.81) using AFI images and 0.85 (0.79-0.89) using AFI + HRE images. The accuracy was 0.69 (0.62-0.74) with AFI images alone and 0.75 (0.70-0.80) using AFI + HRE among non-experts. The IOA for AF positive lesions is fair to moderate using AFI images which improved with addition of HRE. The overall accuracy of identifying dysplasia was modest, and was better when AFI and HRE images were combined.