  1. Use of endobronchial valve insertion to treat relapsing pneumothorax: a case report and literature review.

    Science.gov (United States)

    Qi, Fei; Tian, Qing; Chen, Liang'an; Li, Chunyan; Zhang, Shu; Liu, Xingchen; Xiao, Binbin

    2017-07-01

    Backgorund and Aims: Unidirectional endobronchial valves have recently been shown to be beneficial as treatment for persistent air leaks. This report presents a first case of endobronchial valve implantation to treat relapsing pneumothorax in a Chinese patient, and also presents a review of the literature on the use of one-way valve insertion for the treatment of persistent air leaks. The patient did undergo a recent but failed chest tube intervention. By bronchoscopy and using Chartis® system measurements, the upper left lobe (including the left apical bronchus) was closed using a catheter. After the expected decrease in airflow following bronchial occlusion, increased air pressure and decreased spilled air were noted; it was concluded that the pneumothorax was located in the left upper lobe. A Zephyr ® endobronchial valve was placed in the left upper apical bronchus. The health benefits of the procedure were noticed in the following days. Our review suggests that the use of endobronchial valves could be used as an effective, minimally invasive, low-risk intervention for patients with pneumothorax that cannot be treated surgically. © 2015 John Wiley & Sons Ltd.

  2. Pleural Adhesion Assessment as a Predictor for Pneumothorax after Endobronchial Valve Treatment

    NARCIS (Netherlands)

    van Geffen, Wouter H.; Klooster, Karin; Hartman, Jorine E.; Ten Hacken, Nick H. T.; Kerstjens, Huib A. M.; Wolf, Rienhart F. E.; Slebos, Dirk-Jan

    Background: Pneumothorax after bronchoscopic lung volume reduction using one-way endobronchial valves (EBVs) in patients with advanced emphysema occurs in approximately 20% of patients. It is not well known which factors predict the development of pneumothorax.  Objective: To assess whether pleural

  3. Endobronchial Valves for Endoscopic Lung Volume Reduction : Best Practice Recommendations from Expert Panel on Endoscopic Lung Volume Reduction

    NARCIS (Netherlands)

    Slebos, Dirk-Jan; Shah, Pallav L.; Herth, Felix J. F.; Valipour, Arschang

    Endoscopic lung volume reduction (ELVR) is being adopted as a treatment option for carefully selected patients suffering from severe emphysema. ELVR with the one-way endobronchial Zephyr valves (EBV) has been demonstrated to improve pulmonary function, exercise capacity, and quality of life in

  4. Design of the Endobronchial Valve for Emphysema Palliation Trial (VENT: a non-surgical method of lung volume reduction

    Directory of Open Access Journals (Sweden)

    Noppen Marc

    2007-07-01

    Full Text Available Abstract Background Lung volume reduction surgery is effective at improving lung function, quality of life, and mortality in carefully selected individuals with advanced emphysema. Recently, less invasive bronchoscopic approaches have been designed to utilize these principles while avoiding the associated perioperative risks. The Endobronchial Valve for Emphysema PalliatioN Trial (VENT posits that occlusion of a single pulmonary lobe through bronchoscopically placed Zephyr® endobronchial valves will effect significant improvements in lung function and exercise tolerance with an acceptable risk profile in advanced emphysema. Methods The trial design posted on Clinical trials.gov, on August 10, 2005 proposed an enrollment of 270 subjects. Inclusion criteria included: diagnosis of emphysema with forced expiratory volume in one second (FEV1 100%; residual volume > 150% predicted, and heterogeneous emphysema defined using a quantitative chest computed tomography algorithm. Following standardized pulmonary rehabilitation, patients were randomized 2:1 to receive unilateral lobar placement of endobronchial valves plus optimal medical management or optimal medical management alone. The co-primary endpoint was the mean percent change in FEV1 and six minute walk distance at 180 days. Secondary end-points included mean percent change in St. George's Respiratory Questionnaire score and the mean absolute changes in the maximal work load measured by cycle ergometry, dyspnea (mMRC score, and total oxygen use per day. Per patient response rates in clinically significant improvement/maintenance of FEV1 and six minute walk distance and technical success rates of valve placement were recorded. Apriori response predictors based on quantitative CT and lung physiology were defined. Conclusion If endobronchial valves improve FEV1 and health status with an acceptable safety profile in advanced emphysema, they would offer a novel intervention for this progressive and

  5. Pneumothorax following Endobronchial Valve Therapy and Its Impact on Clinical Outcomes in Severe Emphysema

    NARCIS (Netherlands)

    Gompelmann, Daniela; Herth, Felix J. F.; Slebos, Dirk Jan; Valipour, Arschang; Ernst, Armin; Criner, Gerard J.; Eberhardt, Ralf

    2014-01-01

    Background: Patients who achieve significant target lobe volume reduction (TLVR) following endobronchial valve (EBV) treatment may experience substantial improvements in clinical outcome measures. However, in cases of rapid TLVR, the risk of pneumothorax increases due to parenchymal rupture of the

  6. A Multicenter Randomized Controlled Trial of Zephyr Endobronchial Valve Treatment in Heterogeneous Emphysema (TRANSFORM)

    NARCIS (Netherlands)

    Kemp, Samuel V.; Slebos, Dirk-Jan; Kirk, Alan; Kornaszewska, Malgorzata; Carron, Kris; Ek, Lars; Broman, Gustav; Hillerdal, Gunnar; Mal, Herve; Pison, Christophe; Briault, Amandine; Downer, Nicola; Darwiche, Kaid; Rao, Jagan; Huebner, Ralf-Harto; Ruwwe-Glosenkamp, Christof; Trosini-Desert, Valery; Eberhardt, Ralf; Herth, Felix J.; Derom, Eric; Malfait, Thomas; Shah, Pallav L.; Garner, Justin L.; ten Hacken, Nick H.; Fallouh, Hazem; Leroy, Sylvie; Marquette, Charles H.

    2017-01-01

    Rationale: Single-center randomized controlled trials of the Zephyr endobronchial valve (EBV) treatment have demonstrated benefit in severe heterogeneous emphysema. This is the first multicenter study evaluating this treatment approach. Objectives: To evaluate the efficacy and safety of Zephyr EBVs

  7. [Extracorporeal ventriculoatrial shunt with the use of one-way ball valve].

    Science.gov (United States)

    Kubo, Shigeki; Takimoto, Hiroshi; Hosoi, Kazuki; Toyota, Shingo; Takakura, Shuji; Hayashi, Yasuhiro; Ueno, Masato; Morisako, Toshitaka; Karasawa, Jun; Ninaga, Hideo; Yoshimine, Toshiki

    2002-04-01

    We developed a simple system of an "extracorporeal" ventriculoatrial (VA) shunt using a one-way ball valve (Acty valve II, Kaneka Medix) to release the patient from postoperative constraint during the ventricular drainage. The system is constructed in such a way that the ventricular drainage tube is connected to the central venous catheter via a one-way valve. The CSF is regulated by using the valve and is diverted into the systemic circulation as in the conventional ventriculoatrial shunt. After 2 or 3 weeks of CSF diversion through the extracorporeal VA shunt, a ventriculoperitoneal shunt is placed if hydrocephalus is apparent by temporary occlusion of the system. We applied this system to 4 patients with hydrocephalus, and we found it useful and free from adverse effects. The patient was freed from physical constraint involved in conventional ventricular drainage and an effective program of early rehabilitation was able to be started.

  8. Endobronchial Occlusion Stent: A Preliminary Experimental Study

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yo Won; Jeong, Woo Kyoung; Lee, Seoung Hoon; Heo, Jeong Nam; Jeon, Seok Chol [Hanyang University College of Medicine, Seoul (Korea, Republic of); Ko, Gi Young; Song, Ho Young [University of Ulsan College of Medicine, Ulsan (Korea, Republic of)

    2010-04-15

    To evaluate the safety and the technical feasibility of the use of an endobronchial occlusion stent and to get preliminary data for the development of the optimal material required for endobronchial occlusions. A commercialized, self-expandable tracheobronchial stent was modified; one half had a polyurethane cover with an occluded end and the other half was uncovered with a flaring configuration. The occluded end was placed such that it would face the distal lung. Under fluoroscopic guidance, seven stents were placed at the lower lobar bronchus in 6 mini-pigs. The bronchial obstruction was examined immediately after stent placement. Chest radiographs were taken at days 1, 7, 14, and 28 after stent placement and the removed airways from two, two, one, and one mini-pigs sacrificed on corresponding days were examined for the maintenance of bronchial obstruction. Stents were successfully placed and induced the immediate bronchial obstruction in all mini-pigs. Five of seven airways with occlusion stents maintained an obstruction until the mini-pigs were sacrificed. Proximal stent migration occurred in two mini-pigs (29%), and pulmonary consolidations were observed distal to four of the stents (57%). The placement of an endobronchial occlusion stent and the obstruction of targeted bronchi seem to be feasible, but an add-on check valve should be considered to prevent stent migration and obstructive pneumonia

  9. Significant lung volume reduction with endobronchial valves in a patient despite the presence of microcollaterals masked by low-flow Chartis phenotype

    Directory of Open Access Journals (Sweden)

    Yin Y

    2016-11-01

    Full Text Available Yan Yin,1 Gang Hou,1 Felix J Herth,2 Xiao-bo Wang,1 Qiu-yue Wang,1 Jian Kang1 1Department of Respiratory Medicine, The First Hospital of China Medical University, Shenyang, People’s Republic of China; 2Department of Pneumology and Critical Care Medicine, Thoraxklinik, University of Heidelberg, Heidelberg, Germany Abstract: Satisfactory functional outcomes following bronchoscopic lung volume reduction (BLVR using endobronchial valves (EBVs depend on the absence of collateral ventilation (CV between the target and adjunct lobes. The Chartis system has proven to be useful for determining whether CV is present or absent, but this system can also erroneously indicate the absence of CV, which can lead to BLVR failure. Here, we describe low-flow Chartis phenotype in the target lobe resulted in difficult judgment of existence of CV. Consequently, BLVR with EBVs implanted into the right upper bronchus failed to reduce lung volume or induce atelectasis. Inserting another EBV into the right middle bronchus blocked the latent CV, which led to significant lung volume reduction in the right upper lobe (RUL and right middle lobe (RML and to improve the pulmonary function, 6-min walking distance, and St George respiratory questionnaire scores over a 2-week follow-up period. Low flow in the target lobe is a unique Chartis phenotype and represents the uncertainty of CV, which is a risk factor for the failure of BLVR using EBVs. Clinicians should be aware of this possibility and might be able to resolve the problem by blocking the RUL and RML between which the CV occurs. Keywords: COPD, bronchoscopic lung volume reduction, collateral ventilation, endobronchial valves, Chartis assessment

  10. Effect of endobronchial valve therapy on pulmonary perfusion and ventilation distribution.

    Directory of Open Access Journals (Sweden)

    Carmen Pizarro

    Full Text Available Endoscopic lung volume reduction (ELVR is an emerging therapy for emphysematous COPD. However, any resulting changes in lung perfusion and ventilation remain undetermined. Here, we report ELVR-mediated adaptations in lung perfusion and ventilation, as investigated by means of pulmonary scintigraphy.In this observational study, we enrolled 26 patients (64.9 ± 9.4 yrs, 57.7% male with COPD heterogeneous emphysema undergoing ELVR with endobronchial valves (Zephyr, Pulmonx, Inc.. Mean baseline FEV1 and RV were 32.9% and 253.8% predicted, respectively. Lung scintigraphy was conducted prior to ELVR and eight weeks thereafter. Analyses of perfusion and ventilation shifts were performed and complemented by correlation analyses between paired zones.After ELVR, target zone perfusion showed a mean relative reduction of 43.32% (p<0.001, which was associated with a significant decrease in target zone ventilation (p<0.001. Perfusion of the contralateral untreated zone and of the contralateral total lung exhibited significant increases post-ELVR (p = 0.002 and p = 0.005, respectively; both correlated significantly with the corresponding target zone perfusion adaptations. Likewise, changes in target zone ventilation correlated significantly with ventilatory changes in the contralateral untreated zone and the total contralateral lung (Pearson's r: -0.42, p = 0.04 and Pearson's r: -0.42, p = 0.03, respectively. These effects were observed in case of clinical responsiveness to ELVR, as assessed by changes in the six-minute walk test distance.ELVR induces a relevant decrease in perfusion and ventilation of the treated zone with compensatory perfusional and ventilatory redistribution to the contralateral lung, primarily to the non-concordant, contralateral zone.

  11. Absent Lung Deflation Because of Blockade Using an Endobronchial Blocker.

    Science.gov (United States)

    Garg, Rakesh; Pandit, Anuja

    2017-06-01

    One-lung ventilation is required for various thoracic procedures. In addition, various strategies such as the use of double-lumen tube, uninvent tubes, and endobronchial blocker have been used for performing one-lung ventilation. Each of these techniques has its advantages and limitations. Certain factors for failure of endobronchial blocker to provide lung deflation has been described in literature. We report a different aetiology of failure of lung deflation, although the endobronchial blocker was appropriately placed.

  12. Shape Optimization of Three-Way Reversing Valve for Cavitation Reduction

    International Nuclear Information System (INIS)

    Lee, Myeong Gon; Han, Seung Ho; Lim, Cha Suk

    2015-01-01

    A pair of two-way valves typically is used in automotive washing machines, where the water flow direction is frequently reversed and highly pressurized clean water is sprayed to remove the oil and dirt remaining on machined engine and transmission blocks. Although this valve system has been widely used because of its competitive price, its application is sometimes restricted by surging effects, such as pressure ripples occurring in rapid changes in water flow caused by inaccurate valve control. As an alternative, one three-way reversing valve can replace the valve system because it provides rapid and accurate changes to the water flow direction without any precise control device. However, a cavitation effect occurs because of the complicated bottom plug shape of the valve. In this study, the cavitation index and percent of cavitation (POC) were introduced to numerically evaluate fluid flows via computational fluid dynamics (CFD) analysis. To reduce the cavitation effect generated by the bottom plug, the optimal shape design was carried out through a parametric study, in which a simple computer-aided engineering (CAE) model was applied to avoid time consuming CFD analysis and difficulties in achieving convergence. The optimal shape design process using full factorial design of experiments (DOEs) and an artificial neural network meta-model yielded the optimal waist and tail length of the bottom plug with a POC value of less than 30%, which meets the requirement of no cavitation occurrence. The optimal waist length, tail length and POC value were found to 6.42 mm, 6.96 mm and 27%, respectively

  13. Shape optimization of three-way reversing valve for cavitation reduction

    International Nuclear Information System (INIS)

    Lee, Myeong Gon; Han, Seung Ho; Lim, Cha Suk

    2015-01-01

    A pair of two-way valves typically is used in automotive washing machines, where the water flow direction is frequently reversed and highly pressurized clean water is sprayed to remove the oil and dirt remaining on machined engine and transmission blocks. Although this valve system has been widely used because of its competitive price, its application is sometimes restricted by surging effects, such as pressure ripples occurring in rapid changes in water flow caused by inaccurate valve control. As an alternative, one three-way reversing valve can replace the valve system because it provides rapid and accurate changes to the water flow direction without any precise control device. However, a cavitation effect occurs because of the complicated bottom plug shape of the valve. In this study, the cavitation index and percent of cavitation (POC) were introduced to numerically evaluate fluid flows via computational fluid dynamics (CFD) analysis. To reduce the cavitation effect generated by the bottom plug, the optimal shape design was carried out through a parametric study, in which a simple computer-aided engineering (CAE) model was applied to avoid time-consuming CFD analysis and difficulties in achieving convergence. The optimal shape design process using full factorial design of experiments (DOEs) and an artificial neural network meta-model yielded the optimal waist and tail length of the bottom plug with a POC value of less than 30%, which meets the requirement of no cavitation occurrence. The optimal waist length, tail length and POC value were found to 6.42 mm, 6.96 mm and 27%, respectively

  14. Shape Optimization of Three-Way Reversing Valve for Cavitation Reduction

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myeong Gon; Han, Seung Ho [Donga Univ., Busan (Korea, Republic of); Lim, Cha Suk [Baek San Hi-Tech Co., Ltd., Seoul (Korea, Republic of)

    2015-11-15

    A pair of two-way valves typically is used in automotive washing machines, where the water flow direction is frequently reversed and highly pressurized clean water is sprayed to remove the oil and dirt remaining on machined engine and transmission blocks. Although this valve system has been widely used because of its competitive price, its application is sometimes restricted by surging effects, such as pressure ripples occurring in rapid changes in water flow caused by inaccurate valve control. As an alternative, one three-way reversing valve can replace the valve system because it provides rapid and accurate changes to the water flow direction without any precise control device. However, a cavitation effect occurs because of the complicated bottom plug shape of the valve. In this study, the cavitation index and percent of cavitation (POC) were introduced to numerically evaluate fluid flows via computational fluid dynamics (CFD) analysis. To reduce the cavitation effect generated by the bottom plug, the optimal shape design was carried out through a parametric study, in which a simple computer-aided engineering (CAE) model was applied to avoid time consuming CFD analysis and difficulties in achieving convergence. The optimal shape design process using full factorial design of experiments (DOEs) and an artificial neural network meta-model yielded the optimal waist and tail length of the bottom plug with a POC value of less than 30%, which meets the requirement of no cavitation occurrence. The optimal waist length, tail length and POC value were found to 6.42 mm, 6.96 mm and 27%, respectively.

  15. Shape optimization of three-way reversing valve for cavitation reduction

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myeong Gon; Han, Seung Ho [Dept. of Mechanical Engineering, Dong-A University, Busan (Korea, Republic of); Lim, Cha Suk [Baek San Hi-Tech Co., Ltd., Yangsan(Korea, Republic of)

    2015-11-15

    A pair of two-way valves typically is used in automotive washing machines, where the water flow direction is frequently reversed and highly pressurized clean water is sprayed to remove the oil and dirt remaining on machined engine and transmission blocks. Although this valve system has been widely used because of its competitive price, its application is sometimes restricted by surging effects, such as pressure ripples occurring in rapid changes in water flow caused by inaccurate valve control. As an alternative, one three-way reversing valve can replace the valve system because it provides rapid and accurate changes to the water flow direction without any precise control device. However, a cavitation effect occurs because of the complicated bottom plug shape of the valve. In this study, the cavitation index and percent of cavitation (POC) were introduced to numerically evaluate fluid flows via computational fluid dynamics (CFD) analysis. To reduce the cavitation effect generated by the bottom plug, the optimal shape design was carried out through a parametric study, in which a simple computer-aided engineering (CAE) model was applied to avoid time-consuming CFD analysis and difficulties in achieving convergence. The optimal shape design process using full factorial design of experiments (DOEs) and an artificial neural network meta-model yielded the optimal waist and tail length of the bottom plug with a POC value of less than 30%, which meets the requirement of no cavitation occurrence. The optimal waist length, tail length and POC value were found to 6.42 mm, 6.96 mm and 27%, respectively.

  16. Collimated-hole structures as efficient differential pumping barrier, one-way valve and tool for aligning Penning traps

    International Nuclear Information System (INIS)

    Kluge, H.-Jürgen; Block, Michael; Herfurth, Frank

    2011-01-01

    A collimated-hole structure consists of a very large number of parallel channels which have each a very small diameter and are closely packed together. Such devices, installed in vacuum systems allow one to separate regions of very different gas pressures. A collimated-hole structure has high transmission for a directed ion beam with low emittance but a very low conductance for rest gas atoms or molecules exhibiting random walk. Therefore it is proposed to use such a structure as one-way valve and/or efficient differential pumping barrier in set-ups using Penning traps. Furthermore, these devices might be very useful to align the axis of a Penning trap with the direction of the magnetic field lines which is essential to avoid systematic uncertainties in high-accuracy mass spectroscopy.

  17. Congestive cardiomyopathy and endobronchial granulomas as manifestations of Churg-Strauss syndrome.

    Science.gov (United States)

    Alvarez-Sala, R.; Prados, C.; Armada, E.; Del Arco, A.; Villamor, J.

    1995-01-01

    Churg-Strauss syndrome is a systemic vasculitis. Its most frequent complications are heart diseases and asthma. Usually, cardiological manifestations are pericarditis, cardiac failure and myocardial infarction. Endobronchial granulomas identified by bronchoscopy are unusual. We present the case of a man with congestive cardiomyopathy and endobronchial granulomas macroscopically visible at bronchoscopy. After a review of medical literature, we found one case of congestive cardiomyopathy and no cases of endobronchial granulomas observed by bronchoscopy associated with Churg-Strauss syndrome. Images Figure PMID:7644400

  18. An obstructing endobronchial lipoma simulating COPD

    DEFF Research Database (Denmark)

    Sivapalan, Pradeesh; Gottlieb, Magnus; Christensen, Merete

    2014-01-01

    Endobronchial lipomas are rare benign tumors of the respiratory tract. Bronchial occlusion may cause parenchymal damage and lead to a misdiagnosis of chronic obstructive pulmonary disease or malignancy. Therefore, both accurate diagnosis and radical treatment of endobronchial lipomas are essentia...

  19. Dynamic performance of self-operated three-way valve used in a hybrid air conditioner

    International Nuclear Information System (INIS)

    Zhang, Penglei; Zhou, Dehai; Shi, Wenxing; Li, Xianting; Wang, Baolong

    2014-01-01

    A hybrid air conditioner combining a thermosyphon cycle with a vapor compression refrigeration cycle has a large energy saving potential compared with a common air conditioner for spaces requiring year-round cooling. The performance of the switch between the vapor compression mode and the thermosyphon mode largely impacts the safety and reliability of hybrid air conditioners. Therefore, a self-operated three-way valve is proposed. A thermodynamic model and a kinetic model are developed in this paper to evaluate the dynamic performance of the switch valve. The effects of the spring force constant, compressor discharging volume, fit clearance and piston length on the dynamic performance of the switch valve are analyzed. In conclusion, the proposed self-operated three-way valve can realize the switch operation accurately. - Highlights: •A self-operated three-way valve is proposed for hybrid air conditioners. •The thermodynamic model and kinetic model of the self-operated three-way valve are developed. •The validity of models is verified by experiments. •Effects of four main design parameters on the operating performance of the valve are researched

  20. Endobronchial Tuberculosis and Chest Radiography

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Sasani

    2016-03-01

    Full Text Available Endobronchial tuberculosis and chest radiography I read, with interest, the article entitled “Clinical and Para-clinical Presentations of Endobronchial Tuberculosis” by Ahmadi Hoseini H. S. et al. (1 published in this journal. I would like to focus on some details about the chest X-ray of patients as elaborated by the authors in the results section. Accordingly, the findings of chest radiography in the available patients were as follows: pulmonary consolidation (75%, reduced pulmonary volume (20%, and hilar adenopathy (10%. This is an incomplete statement because the authors did not explain whether there was any normal chest radiography in the study population. In addition, it is not clear whether the X-ray examinations of the patients were normal, how many abnormal plain films yielded the presented data. On the other hand, the fact that the studied patients had no normal chest radiography is  controversial since in the literature, 10-20% of the patients with endobronchial tuberculosis are reported to have normal chest X-ray (2, 3. In fact, this is one of the problems in the diagnosis of the disease, as well as a potential cause of delayed diagnosis and treatment of the patients. Therefore, the absence of normal chest radiographs is in contrast to the available literature, and if not an error, it could be a subject of further investigation.

  1. Video-assisted lobectomy for endobronchial leiomyoma.

    LENUS (Irish Health Repository)

    Bartosik, Waldemar

    2011-02-01

    Endobronchial leiomyomas are rare tumours arising from the smooth muscle on the bronchial tree. We describe a patient with a six-month history of chest infections, who was treated surgically with a video-assisted thoracic surgery (VATS) lobectomy. The pathology revealed an endobronchial leiomyoma that coexisted with postobstructive pulmonary non-necrotising granulomas.

  2. One-shot valve may be remotely actuated

    Science.gov (United States)

    Kami, S.

    1965-01-01

    One-shot valve, with spring-loaded plunger and sealing diaphragm, incorporates an emergency release actuated by a remote sensor. The plunger is released by the electrical melting of a fuse link and pierces the valve seal. The valve lowers fluid pressure in a container without losing the contained fluid.

  3. Endobronchial valves in severe emphysematous patients: CT evaluation of lung fissures completeness, treatment radiological response and quantitative emphysema analysis

    Energy Technology Data Exchange (ETDEWEB)

    Koenigkam-Santos, Marcel, E-mail: marcelk46@yahoo.com.br, E-mail: marcelk46@usp.b [Universidade de Sao Paulo (HCFMRP/USP), Ribeirao Preto, SP (Brazil). Hospital das Clinicas da Faculdade de Medicina; Paula, Wagner Diniz de [University of Brasilia (UnB), DF (Brazil). Brasilia University Hospital; Gompelmann, Daniela [University of Heidelberg (Germany). Department of Pneumology and Respiratory Medicine of the Chest Clinic (Thoraxklinik); Kauczor, Hans-Ulrich [University of Heidelberg (Germany). Department of Diagnostic and Interventional Radiology; Heussel, Claus Peter; Puderbach, Michael [University of Heidelberg (Germany). Department of Diagnostic and Interventional Radiology with Nuclear Medicine of the Chest Clinic (Thoraxklinik)

    2013-01-15

    Objective: To evaluate lung fissures completeness, post-treatment radiological response and quantitative CT analysis (QCTA) in a population of severe emphysematous patients submitted to endobronchial valves (EBV) implantation. Materials and Methods: Multi-detectors CT exams of 29 patients were studied, using thin-section low dose protocol without contrast. Two radiologists retrospectively reviewed all images in consensus; fissures completeness was estimated in 5% increments and post-EBV radiological response (target lobe atelectasis/volume loss) was evaluated. QCTA was performed in pre and post-treatment scans using a fully automated software. Results: CT response was present in 16/29 patients. In the negative CT response group, all 13 patients presented incomplete fissures, and mean oblique fissures completeness was 72.8%, against 88.3% in the other group. QCTA most significant results showed a reduced post-treatment total lung volume (LV) (mean 542 ml), reduced EBV-submitted LV (700 ml) and reduced emphysema volume (331.4 ml) in the positive response group, which also showed improved functional tests. Conclusion: EBV benefit is most likely in patients who have complete interlobar fissures and develop lobar atelectasis. In patients with no radiological response we observed a higher prevalence of incomplete fissures and a greater degree of incompleteness. The fully automated QCTA detected the post-treatment alterations, especially in the treated lung analysis. (author)

  4. A case of endobronchial lipoma mimicking bronchial asthma

    Directory of Open Access Journals (Sweden)

    Sevket Ozkaya

    2009-05-01

    Full Text Available Sevket Ozkaya1, Hasan Demir1, Serhat Findik21Samsun Chest Diseases and Thoracic Surgery Hospital, Samsun, Turkey; 2Department of Pulmonary Medicine, Faculty of Medicine, Ondokuz Mayis University, Kurupelit, Samsun, TurkeyAbstract: Endobronchial lipoma is a rare neoplasm of the tracheobronchial tree and it may cause irreversible pulmonary damage due to recurrent pneumonia. Rarely, it may mimic bronchial asthma. We present a 53-year-old woman with an endobronchial lipoma, which had been treated as a bronchial asthma for four years. She also had developed recurrent pneumonia three times.Keywords: endobronchial lipoma, asthma, radiology, bronchoscopy

  5. A new one-step procedure for pulmonary valve implantation of the melody valve: Simultaneous prestenting and valve implantation.

    Science.gov (United States)

    Boudjemline, Younes

    2018-01-01

    To describe a new modification, the one-step procedure, that allows interventionists to pre-stent and implant a Melody valve simultaneously. Percutaneous pulmonary valve implantation (PPVI) is the standard of care for managing patients with dysfunctional right ventricular outflow tract, and the approach is standardized. Patients undergoing PPVI using the one-step procedure were identified in our database. Procedural data and radiation exposure were compared to those in a matched group of patients who underwent PPVI using the conventional two-step procedure. Between January 2016 and January 2017, PPVI was performed in 27 patients (median age/range, 19.1/10-55 years) using the one-step procedure involving manual crimping of one to three bare metal stents over the Melody valve. The stent and Melody valve were delivered successfully using the Ensemble delivery system. No complications occurred. All patients had excellent hemodynamic results (median/range post-PPVI right ventricular to pulmonary artery gradient, 9/0-20 mmHg). Valve function was excellent. Median procedural and fluoroscopic times were 56 and 10.2 min, respectively, which significantly differed from those of the two-step procedure group. Similarly, the dose area product (DAP), and radiation time were statistically lower in the one-step group than in the two-step group (P step procedure is a safe modification that allows interventionists to prestent and implants the Melody valve simultaneously. It significantly reduces procedural and fluoroscopic times, and radiation exposure. © 2017 Wiley Periodicals, Inc.

  6. Cost-effectiveness of endobronchial valve treatment in patients with severe emphysema compared to standard medical care.

    Science.gov (United States)

    Hartman, Jorine E; Klooster, Karin; Groen, Henk; Ten Hacken, Nick H T; Slebos, Dirk-Jan

    2018-03-25

    Bronchoscopic lung volume reduction using endobronchial valves (EBV) is an effective new treatment option for severe emphysema patients without interlobar collateral ventilation. The objective of this study was to perform an economic evaluation including the costs and cost-effectiveness of EBV treatment compared with standard medical care (SoC) from the hospital perspective in the short term and long term. For the short-term evaluation, incremental cost-effectiveness ratios (ICER) were calculated based on the 6-month end point data from the STELVIO randomized trial. For the long-term evaluation, a Markov simulation model was constructed based on STELVIO and literature. The clinical outcome data were quality-adjusted life-years (QALY) based on the EuroQol5-Dimensions (EQ5D) questionnaire, the 6-min walking distance (6MWD) and the St George's Respiratory Questionnaire (SGRQ). The mean difference between the EBV group and controls was €16 721/patient. In the short-term (6 months), costs per additional QALY was €205 129, the ICER for 6MWD was €160 and for SGRQ was €1241. In the long term, the resulting cost-effectiveness ratios indicate additional costs of €39 000 per QALY gained with a 5-year time horizon and €21 500 per QALY gained at 10 years. In comparison, historical costs per additional QALY 1 year after the coil treatment are €738 400, 5 years after lung volume reduction surgery are €48 415 and 15 years after double-lung transplantation are €29 410. The positive clinical effects of EBV treatment are associated with increased costs compared with SoC. Our results suggest that the EBV treatment has a favourable cost-effectiveness profile, also when compared with other treatment modalities for this patient group. © 2018 Asian Pacific Society of Respirology.

  7. Endobronchial ultrasound elastography: a new method in endobronchial ultrasound-guided transbronchial needle aspiration.

    Science.gov (United States)

    Jiang, Jun-Hong; Turner, J Francis; Huang, Jian-An

    2015-12-01

    TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS

  8. Bronchoscopic lung volume reduction by endobronchial valve in advanced emphysema: the first Asian report

    Directory of Open Access Journals (Sweden)

    Park TS

    2015-07-01

    Full Text Available Tai Sun Park,1 Yoonki Hong,2 Jae Seung Lee,1 Sang Young Oh,3 Sang Min Lee,3 Namkug Kim,3 Joon Beom Seo,3 Yeon-Mok Oh,1 Sang-Do Lee,1 Sei Won Lee1 1Department of Pulmonary and Critical Care Medicine and Clinical Research Center for Chronic Obstructive Airway Diseases, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea; 2Department of Internal Medicine, College of Medicine, Kangwon National University, Chuncheon, Korea; 3Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea Purpose: Endobronchial valve (EBV therapy is increasingly being seen as a therapeutic option for advanced emphysema, but its clinical utility in Asian populations, who may have different phenotypes to other ethnic populations, has not been assessed.Patients and methods: This prospective open-label single-arm clinical trial examined the clinical efficacy and the safety of EBV in 43 consecutive patients (mean age 68.4±7.5, forced expiratory volume in 1 second [FEV1] 24.5%±10.7% predicted, residual volume 208.7%±47.9% predicted with severe emphysema with complete fissure and no collateral ventilation in a tertiary referral hospital in Korea.Results: Compared to baseline, the patients exhibited significant improvements 6 months after EBV therapy in terms of FEV1 (from 0.68±0.26 L to 0.92±0.40 L; P<0.001, 6-minute walk distance (from 233.5±114.8 m to 299.6±87.5 m; P=0.012, modified Medical Research Council dyspnea scale (from 3.7±0.6 to 2.4±1.2; P<0.001, and St George’s Respiratory Questionnaire (from 65.59±13.07 to 53.76±11.40; P=0.028. Nine patients (20.9% had a tuberculosis scar, but these scars did not affect target lobe volume reduction or pneumothorax frequency. Thirteen patients had adverse events, ten (23.3% developed pneumothorax, which included one death due to tension pneumothorax.Conclusion: EBV therapy was as effective and safe in Korean

  9. Endobronchial brachytherapy: the Saint-Louis Hospital experience

    International Nuclear Information System (INIS)

    Hennequin, C.; Durdux, C.; Housset, M.; Maylin, C.; Tredaniel, J.; Zalcman, G.; Hirsch, A.; Dray, M.; Manoux, D.; Perret, M.

    1997-01-01

    During the evolution of lung cancer, bronchial obstruction is often noticed and is sometimes responsible for serious symptoms. Several methods of des-obstruction can be proposed, including brachytherapy. Materials and methods: One hundred forty-nine patients, presenting with endobronchial brachytherapy were included into the study. Seventy-three were treated with curative intent, 47 with palliative intent and 29 with a combination of external irradiation and brachytherapy. We usually delivered a series of two 7-Gy fractions (1 cm from the catheter), the treatment being repeated one, two or three times. Results: When all symptoms were taken into account, respiratory function improvement was present in 79% of the patients. Among the 132 tumors that could be evaluated via a new endoscopy 2 months after treatment, 64 (48.5%) were in complete histological remission. The median survival was 14.4 months for the patients treated with curative intent. Eleven massive hemoptyses and 13 radiation bronchitides were observed. Conclusion: These results confirm the feasibility and good results related to endobronchial brachytherapy, though controlled studies are needed to better define its place in the therapeutic strategy of bronchial carcinomas. (authors)

  10. Long-term results of curative intraluminal high dose rate brachytherapy for endobronchial carcinoma

    Directory of Open Access Journals (Sweden)

    Kawamura Hidemasa

    2012-07-01

    Full Text Available Abstract Background The treatment strategy of central lung tumors is not established. Intraluminal brachytherapy (ILBT is widely used for palliative treatment of endobronchial tumors, however, it is also a promising option for curative treatment with limited data. This study evaluates the results after ILBT for endobronchial carcinoma. Method Sixteen-endobronchial carcinoma of 13 patients treated with ILBT in curative intent for 2000 to 2008 were retrospectively reviewed. ILBT using high dose rate 192 iridium thin wire system was performed with 5 Gy/fraction at mucosal surface. The patient age ranged from 57 to 82 years old with median 75 years old. The 16 lesions consisted of 13 central endobronchial cancers including 7 roentgenographically occult lung cancers and 3 of tracheal cancers. Of them, 10 lesions were treated with ILBT of median 20 Gy combined with external beam radiation therapy of median 45 Gy and 6 lesions were treated with ILBT alone of median 25 Gy. Results Median follow-up time was 32.5 months. Two-year survival rate and local control rate were 92.3% and 86.2%, respectively. Local recurrences were observed in 2 lesions. Three patients died due to lung cancer (1 patient and intercurrent disease (2 patients. Complications greater than grade 2 were not observed except for one grade 3 dyspnea. Conclusions ILBT combined with or without EBRT might be a curative treatment option in inoperable endobronchial carcinoma patients with tolerable complication.

  11. VALVE BRONCHIAL BLOCK IN THE INTEGRATED TREATMENT OF BRONCHIAL PLEURAL FISTULAS AFTER SURGICAL REDUCTION OF PULMONARY VOLUME

    Directory of Open Access Journals (Sweden)

    E. A. Tseymakh

    2015-01-01

    Full Text Available Formation of bronchopleural fistulas after surgical reduction of pulmonary volume is one of the most frequent complications of surgical treatment of pulmonary emphysema. In order to control bronchopleural fistulas in the patients after surgical reduction of pulmonary volume the technique of valve bronchial block has been o}ered. This technique has been applied in 7 patients, and the favorable outcomes have been achieved in 6 (85.7% patients. The use of endobronchial valve for occlusion of fistulous bronchi allowed stopping air leaking through drainages, reducing time for pleural cavity drain and decreasing duration of patients' hospital stay.

  12. Diffuse bronchiectasis as the primary manifestation of endobronchial sarcoidosis

    Directory of Open Access Journals (Sweden)

    Paul D. Hiles

    2017-01-01

    Full Text Available Sarcoidosis is an idiopathic disease that most commonly involves the lungs and is characterized by granulomatous inflammation. Bronchiectasis is one pulmonary manifestation of sarcoidosis, although it is almost always observed as traction bronchiectasis in the setting of fibrotic lung disease. A 50-year-old woman was evaluated for chronic cough and bronchiectasis with a small amount of peripheral upper lobe honeycombing and no significant pulmonary fibrosis or lymphadenopathy. After an extensive laboratory and imaging evaluation did not identify a cause of her bronchiectasis, bronchoscopy was performed to assess for primary ciliary dyskinesia and revealed a diffuse cobblestone appearance of the airway mucosa. Endobronchial biopsies and lymphocyte subset analysis of bronchoalveolar lavage fluid were consistent with a diagnosis of sarcoidosis. We believe endobronchial sarcoidosis should be included in the differential diagnosis of patients presenting with bronchiectasis.

  13. Endobronchial angiofibroma in the aberrant tracheal bronchus presenting as spontaneous pneumomediastinum.

    Science.gov (United States)

    Kim, Kyung Soo; Moon, Young Kyu; Jeon, Hyun Woo; Park, Chan Beom; Ahn, Myeong Im; Lee, Kyo Young; Park, Jae Kil

    2015-07-22

    Spontaneous pneumomediastinum is a self-limiting benign disease but abnormal bronchial lesions can be rarely found incidentally, and in selected cases will require surgical resection. A 38-year-old man presented with a spontaneous pneumomediastinum. Chest computed tomography revealed an incidental linear endobronchial tumour in the aberrant tracheal bronchus. The tumour was removed surgically and diagnosed with a rare benign tumour of endobronchial angiofibroma. We report a rare case of endobronchial angiofibroma in the aberrant tracheal bronchus which was detected during the evaluation of a spontaneous pneumomediastinum.

  14. Bronchoscopic management of a rare benign endobronchial tumor

    Directory of Open Access Journals (Sweden)

    K. Madan

    2012-09-01

    Full Text Available Benign endobronchial tumors are uncommon. Bronchoscopic removal is the preferred modality of treatment although surgery may be required in some cases. Rigid bronchoscopy is usually recommended in the management of these tumors. However, flexible bronchoscopy is also used in many centers. We present a case of endobronchial lipoma, where an unusual complication during flexible bronchoscopic resection using snare forceps necessitated urgent rigid bronchoscopy. This case highlights the importance of rigid bronchoscopy in the management of endobronchial tumors. We believe that with a large benign endobronchial tumor in tracheal or main-stem bronchus, physicians should initially employ rigid bronchoscopy, switching to flexible if more peripheral treatment is required. Resumo: Os tumores endobrônquicos benignos são raros. A remoção broncoscópica é a modalidade de tratamento preferida, embora a cirurgia possa ser necessária em alguns casos. A broncoscopia rígida é geralmente considerada a modalidade preferencial na abordagem destes tumores. No entanto, a broncoscopia flexível também é utilizada em muitos centros. Apresentamos um caso de lipoma endobrônquico, onde uma complicação invulgar durante a ressecção broncoscópica flexível utilizando pinças de laço necessitou de uma urgente broncoscopia rígida. Neste caso, destaca-se a importância da broncoscopia rígida na abordagem dos tumores endobrônquicos. Acreditamos que com um tumor endobrônquico benigno de grandes dimensões da traqueia ou do brônquio principal, os médicos devem inicialmente utilizar a broncoscopia rígida, alternando para a flexível, se for necessário um tratamento mais periférico. Keywords: Bronchoscopy, Lipoma, Endobronchial tumor, Electrocautery, Interventional pulmonology, Palavras-chave: Broncoscopia, Lipoma, Tumor endobrônquico, Electrocautério, Pneumologia interventiva

  15. Endobronchial Epstein-Barr Virus Associated Post-transplant Lymphoproliferative Disorder in Hematopoietic Stem Cell Transplantation

    Directory of Open Access Journals (Sweden)

    S. Feuillet

    2009-01-01

    Full Text Available The Epstein-Barr virus (EBV associated Post-Transplant Lymphoproliferative Disorders (PTLD are increasingly recognized as a fatal complication of hematological stem cell transplantation (HSCT. Thoracic involvement, that may be isolated or part of a disseminated disease, usually encompasses pulmonary nodules or masses and mediastinal lymph node enlargement. The current case study presents 2 patients who underwent HSCT, one allogenic and the other autologous, who developed an exceptional endobronchial EBV related PTLD. The first patient had a fleshy white endobronchial mass resulting in a right upper lobe atelectasis and the second had an extensive necrotising mucosa from trachea to both basal bronchi without any significant change of lung parenchyma on the CT scan. In both cases, the diagnosis was made by bronchial biopsies. Physicians should be aware of an endobronchial pattern of EBV associated PTLD after HSCT to permit quick diagnosis and therapeutic intervention.

  16. Differentiation between endobronchial tuberculosis and bronchogenic carcinoma associated with atelectasis or obstructive pneumonitis: CT evaluation

    International Nuclear Information System (INIS)

    Chung, Hwan Hoon; Oh, Yu Whan; Kim, Kyeong Ah; Kim, Jung Hyuk

    1995-01-01

    Endobronchial tuberculosis and bronchogenic cancer are common causes of atelectasis or obstructive pneumonitis in Korea. Differentiation between endobronchial tuberculosis and bronchogenic carcinoma is important for the treatment and prognosis but it is sometimes difficult to differentiate these two lesions with radiologic examinations. The purpose of this study was to find the differential points between endobronchial tuberculosis and bronchogenic carcinoma associated with atelectasis or obstructive pneumonitis. Forty patients in whom atelectasis or obstructive pneumonitis was detected on chest radiographs comprised the study. A definite mass opacity was not observed on chest radiographs in all patients. In these patients, the causes of obstruction were endobronchial tuberculosis (n = 20) and bronchogenic cancer (n = 20) which were microbiologically or pathologically confirmed. Double obstructive lesions were more frequently found in endobronchial tuberculosis (8/20) than in bronchogenic cancer (1/20). Multiple calcification along the bronchial wall and severe distortion of bronchi were observed only in endobronchial tuberculosis (4/20) and associated low density mass at obstruction site was only observed in bronchogenic cancer (6/20). Bronchial dilatation (11/20) and parenchymal calcifications (14/20) distal to obstruction site, air containing bronchogram at post obstructive bronchus (14/20) were more frequently found in endobronchial tuberculosis. Contour bulging at obstruction site (14/20), and only mucus bronchogram at post obstructive bronchus (14/20) were more frequently found in bronchogenic carcinoma. In patients with atelectasis or obstructive pneumonitis, endobronchial tuberculosis is characterized by double obstructive lesion, multiple calcifications at the bronchial wall, and severe distortion of the bronchi. Endobronchial carcinoma is characterized by a low density mass at the obstructive site

  17. High dose rate endobronchial brachytherapy - treatment technique

    International Nuclear Information System (INIS)

    Carvalho, Heloisa de Andrade; Aisen, Salim; Haddad, Cecilia Maria Kalil; Nadalin, Wladimir; Pedreira Junior, Wilson Leite; Chavantes, Maria Cristina

    1998-01-01

    High dose rate endobronchial brachytherapy is efficient in symptom relief due to obstructive endobronchial malignancies. However, it's role in survival improvement for patients with lung cancer is not yet established. The use of this treatment in increasing, specially in the developing countries. The purpose of this paper is to present the treatment technique used in the Radiotherapy Department of the Hospital da Clinicas, University of Sao Paulo, based on an experience of 60 cases treated with 180 procedures. Some practical suggestions and rules adopted in the Department are described. The severe complications rate is 6.7%, demonstrating an adequate patient selection associated with the technique utilized. (author)

  18. Endobronchial aspergilloma: report of 10 cases and literature review.

    Science.gov (United States)

    Ma, Jeong Eun; Yun, Eun Young; Kim, You Eun; Lee, Gi Dong; Cho, Yu Ji; Jeong, Yi Yeong; Jeon, Kyoung-Nyeo; Jang, In Seok; Kim, Ho Cheol; Lee, Jong Deok; Hwang, Young Sil

    2011-09-01

    A retrospective investigation of the clinical and radiologic features as well as the bronchoscopic appearance was carried out in patients with endobronchial aspergilloma. Ten patients with endobronchial aspergilloma diagnosed by bronchoscopy and histological examination were identified at the Gyeongsang University Hospital of Korea, from May 2003 to May 2009. The patients included 9 men and 1 woman, and the age of the patients ranged from 36 to 76 (median, 58 years). The associated diseases or conditions were: previous pulmonary tuberculosis in 7 patients, lung cancer in 2 patients, pulmonary resection in 1 patient, and foreign body of the bronchus in 1 patient. The chest radiologic finding showed fibrotic changes as a consequence of previous tuberculosis infection in 6 patients and a mass-like lesion in 2 patients. Two patients had a co-existing fungus ball, and an endobronchial lesion was suspected in only 2 patients on the CT scan. The bronchoscopic appearance was a whitish to yellow necrotic mass causing bronchial obstruction in 7 patients, foreign body with adjacent granulation tissue and whitish necrotic tissue in 1 patient, whitish necrotic tissue at an anastomosis site in 1 patient, and a protruding mass with whitish necrotic tissue in 1 patient. An endobronchial aspergilloma is a rare presentation of pulmonary aspergilosis and is usually incidentally found in immunocompetent patients with underlying lung disease. It usually appears as a necrotic mass causing bronchial obstruction on bronchoscopy and can be confirmed by biopsy.

  19. Tracheobronchial puncture-site nodular reaction (TPNR following endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA: Systematic review of case reports

    Directory of Open Access Journals (Sweden)

    Karan Madan

    2017-01-01

    Full Text Available Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA is a minimally invasive and efficacious diagnostic modality for lung cancer staging and evaluation of undiagnosed mediastinal lymphadenopathy. Procedure-related complications are uncommon. We herein report an infrequently described phenomenon following EBUS-TBNA in which two patients developed nodular granulation tissue at the tracheobronchial puncture site. On systematic review, we found description of such phenomena by terminologies such as endobronchial inflammatory polyp, granuloma, and endobronchial mass. The endobronchial inflammatory polyp has been one of the most commonly used terminologies for these; but in most cases, the classical features of an inflammatory polyp are lacking. We propose the term, tracheobronchial puncture-site nodular reaction (TPNR with further classification into granulomatous and nongranulomatous subtypes, for standardized reporting of such reactions following transbronchial needle aspiration procedures. Knowledge of this entity and standardized nomenclature shall help in better characterization of the outcomes and risk factors for the occurrence of these reactions.

  20. Endobronchial Electrocautery and Argon Plasma Coagulation: A Practical Approach

    Directory of Open Access Journals (Sweden)

    Alain Tremblay

    2004-01-01

    Full Text Available The present review covers the technical and practical aspects of endobronchial electrocautery, including argon plasma coagulation, which have great potential for widespread use by pulmonologists around the world. The various electrocautery modes, power settings and electrode probes are described in detail, and the authors' clinical and technical approach is demonstrated with a narrative description and brief case presentations. Malignant airway obstruction, hemoptysis, web-like stenosis, stent related granulation tissue and early lung carcinomas are the most common indications for treatment. Advantages of electrocautery, such as low cost, rapid effect, safety and ease of use, are contrasted to other endobronchial therapeutic modalities. Published experience with electrocautery is reviewed.

  1. Endobronchial Ultrasound (EBUS) - Update 2017.

    Science.gov (United States)

    Darwiche, Kaid; Özkan, Filiz; Wolters, Celina; Eisenmann, Stephan

    2018-02-01

    Endobronchial ultrasound (EBUS) has revolutionized the diagnosis of lung cancer over the last decade. This minimally invasive diagnostic method has also become increasingly important in the case of other diseases such as sarcoidosis, thereby helping to avoid unnecessary diagnostic interventions. This review article provides an update regarding EBUS and discusses current and future developments of this method. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Endobronchial metastasis: CT findings and its usefulness in bronchoscopic correlation

    International Nuclear Information System (INIS)

    Ko, Ji Ho; Jung, Gyoo Sik; Kim, Seong Min; Huh Jin Do; Joh, Young Duk; Jang, Tae Weon

    2000-01-01

    To evaluate the CT findings of bronchial abnormalities in patients with endobronchial metastasis from extrapulmonary tumors, and to correlate these with the bronchoscopic findings. The authors retrospectively reviewed the CT and bronchoscopic findings of 17 patients (M:F =3D 9:8; mean age, 56 years) with histologically proven endobronchial metastasis from extrapulmonary primary tumors. Carcinoma of the uterine cervix (n=3D5) was the most common primary site for endobronchial metastasis. CT findings of bronchial abnormalities with associated peribronchial and lung parenchymal lesions were analyzed and compared with the bronchoscopic findings. Among the 17 patients, 20 sites of bronchial abnormalities were visualized bronchoscopically. CT findings of bronchial abnormalities were smooth narrowing (n=3D11), occlusion (n=3D3), intraluminal mass (n=3D4), and normal (n=3D2). Peribronchial lesions (lymph node enlargement or parenchymal mass) were found in 12 cases. Bronchoscopy revealed bronchial narrowing due to a mucosal nodule or intraluminal polypoid mass in 16 cases, and total obstruction of the bronchus in four. With regard to the identification of bronchial abnormalities, the findings of CT and of bronchoscopy agreed in 17 cases and disagreed in three. While bronchoscopy was advantageous for detecting early mucosal abnormality, CT effectively evaluated the extent of a lesion beyond the stenosis or bronchial obstruction. CT was also useful for predicting the causes of bronchial abnormalities. CT is relatively accurate in evaluating bronchial abnormalities, and in patients with endobronchial metastases may be used as a complementary procedure to bronchoscopy for evaluating the extent of the lesion. (author)

  3. Independent deterministic analysis of the operational event with turbine valve closure and one atmospheric dump valve stuck open

    International Nuclear Information System (INIS)

    Rijova, N.

    2007-01-01

    The paper presents the results of the independent analysis of the operational event which took place on 07.11.2003 at Unit 1 of Rostov NPP. The event started with switching off the electrical generator of the turbine due to a short cut at the local switching substation. The turbine isolating valves closed to prevent damage of the turbine. The condenser dump valves (BRU-K) and the atmospheric dump valves (BRU-A) opened to release the vapour generated in the steam generators. After the pressure decrease in the steam generators BRU-K and BRU-A closed but one valve stuck opened. The emergency core cooling system was activated automatically. The main circulation pump of the loop corresponding to the steam generator with the stuck BRU-A was tripped. The stuck valve was closed by the operational stuff manually. No safety limits were violated. The analysis of the event was carried out using ATHLET code. A reasonable agreement was achieved between the calculated and measured values. (author)

  4. Clinical challenges of persistent pulmonary air-leaks--case report.

    Science.gov (United States)

    van Zeller, M; Bastos, P; Fernandes, G; Magalhães, A

    2014-01-01

    Air leaks are a common problem after pulmonary resection and can be a source of significant morbidity and mortality. The authors describe the case of a 68-year-old male patient who presented with a persistent air-leak after pulmonary resection. Watchful waiting, surgical procedures, as well as medical therapy like pleurodesis and implantation of endobronchial one-way valves on the bronchial segments identified using systematic occlusion of the bronchial segments, were all tried unsuccessfully. During that time the patient remained hospitalized with a chest tube. The instillation of methylene blue through the chest tube was used to identify the segments leading to the persistent air-leak; this enabled successful endobronchial valve placement which sufficiently reduced the size of the air-leak so that the chest tube could be removed. Nonsurgical approaches seem promising and, for some patients may be the only treatment option after all conventional treatments have failed or are considered too high risk. Copyright © 2013 Sociedade Portuguesa de Pneumologia. Published by Elsevier España. All rights reserved.

  5. The JUPITER registry: One-year outcomes of transapical aortic valve implantation using a second generation transcatheter heart valve for aortic regurgitation.

    Science.gov (United States)

    Silaschi, Miriam; Conradi, Lenard; Wendler, Olaf; Schlingloff, Friederike; Kappert, Utz; Rastan, Ardawan J; Baumbach, Hardy; Holzhey, David; Eichinger, Walter; Bader, Ralf; Treede, Hendrik

    2018-06-01

    We present 1-year outcomes of the post-market registry of a next-generation transcatheter heart valve used for aortic regurgitation (AR). Transcatheter aortic valve replacement (TAVR) is routine in high-risk patients with aortic stenosis but is not recommended for AR. The JenaValve™ (JenaValve Technology GmbH, Munich, Germany) overcomes technical challenges in AR patients through a leaflet clipping mechanism. The JenaValve EvalUation of Long Term Performance and Safety In PaTients with SEvere Aortic Stenosis oR Aortic Insufficiency (JUPITER) Registry is a European study to evaluate safety and effectiveness of this THV. From 2012-2015, 30 patients with AR were enrolled. Mean age was 74.4 ± 9.3 years. Procedural success was 96.7% (29/30). One patient was converted to open surgery. No annular rupture or coronary ostia obstruction occurred. Mortality at 30 days was 10.0% (3/30). Combined safety endpoint was met in 13.3% (4/30). Paravalvular regurgitation was not present/trivial in 84.6% (22/26) and mild in 15.4% (4/26). Rate of permanent pacemaker implantation was 3.8% (1/26). One-year Kaplan-Meier survival was 79.9%, one-year combined efficacy was 73.1% (19/30). No further strokes were observed during 1 year of follow-up. The JenaValve overcomes technical challenges of TAVR in AR through a clipping mechanism. We report satisfactory outcomes of a multicenter registry using the JenaValve for predominant AR, as rate of THV embolization, residual AR and permanent pacemaker implantation was low. One-year results using the JenaValve for AR encourage its use for this indication. © 2017 Wiley Periodicals, Inc.

  6. Fractal dimension analysis of malignant and benign endobronchial ultrasound nodes

    International Nuclear Information System (INIS)

    Fiz, José Antonio; Monte-Moreno, Enrique; Andreo, Felipe; Auteri, Santiago José; Sanz-Santos, José; Serra, Pere; Bonet, Gloria; Castellà, Eva; Manzano, Juan Ruiz

    2014-01-01

    Endobronchial ultrasonography (EBUS) has been applied as a routine procedure for the diagnostic of hiliar and mediastinal nodes. The authors assessed the relationship between the echographic appearance of mediastinal nodes, based on endobronchial ultrasound images, and the likelihood of malignancy. The images of twelve malignant and eleven benign nodes were evaluated. A previous processing method was applied to improve the quality of the images and to enhance the details. Texture and morphology parameters analyzed were: the image texture of the echographies and a fractal dimension that expressed the relationship between area and perimeter of the structures that appear in the image, and characterizes the convoluted inner structure of the hiliar and mediastinal nodes. Processed images showed that relationship between log perimeter and log area of hilar nodes was lineal (i.e. perimeter vs. area follow a power law). Fractal dimension was lower in the malignant nodes compared with non-malignant nodes (1.47(0.09), 1.53(0.10) mean(SD), Mann–Whitney U test p < 0.05)). Fractal dimension of ultrasonographic images of mediastinal nodes obtained through endobronchial ultrasound differ in malignant nodes from non-malignant. This parameter could differentiate malignat and non-malignat mediastinic and hiliar nodes

  7. Single-incision video-assisted anatomical segmentectomy with handsewn bronchial closure for endobronchial lipoma.

    Science.gov (United States)

    Galvez, Carlos; Sesma, Julio; Bolufer, Sergio; Lirio, Francisco; Navarro-Martinez, Jose; Galiana, Maria; Baschwitz, Benno; Rivera, Maria Jesus

    2016-08-01

    Endobronchial lipomas are rare benign tumors whose symptoms are usually confused with recurrent infections or even asthma diagnosis, and mostly caused by endobronquial obstructive component which also conditions severity. We report a case of a 60-year-old man with a right-lower lobe upper-segment endobronchial myxoid tumor with uncertain diagnosis. We performed a single incision video-assisted anatomical segmentectomy and wedge bronchoplasty with handsewn closure to achieve complete resection and definitive diagnosis. During the postoperative air leak was not observed and there was no complication, with low pain scores and complete recovery. Final pathological exam showed endobronchial lipoma. Single-incision (SI) anatomical segmentectomies are lung-sparing resections for benign or low-grade malignancies with diagnostic and therapeutic value, and the need for a wedge bronchoplasty is not a necessary indication for conversion to multiport or open thoracotomy.

  8. Remote Afterloading High Dose Rate (HDR) Endobronchial Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Hyesook; Choi, Eun Kyung; Yi, Byong Yong; Kim, Won Dong; Kim, Woo Sung; Koh, Youn Suck [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    1991-12-15

    Authors described the remote afterloading endobronchial brachytherapy (EBBT) technique using the microSelectron HDR Ir-192 and the Asan Medical Center experience. Total 28 EBBT in 9 patients were performed since November 1989 and 24 EBBT in 8 patients were employed for palliation and 3 EBBT in 1 patient was treated curatively. Authors observed a significant relief of obstructive symptom with tumor regression in 7 patients out of 8 who were treated palliatively but one of them died of pulmonary congestion in 3 weeks after EBBT. One patient with prior therapy of extensive electrocautery expired within 1 day after 2nd EBBT procedure with massive hemorrhage from the lesion. EBBT procedure has been tolerable and can be performed as an outpatient.

  9. Remote Afterloading High Dose Rate (HDR) Endobronchial Brachytherapy

    International Nuclear Information System (INIS)

    Chang, Hyesook; Choi, Eun Kyung; Yi, Byong Yong; Kim, Won Dong; Kim, Woo Sung; Koh, Youn Suck

    1991-01-01

    Authors described the remote afterloading endobronchial brachytherapy (EBBT) technique using the microSelectron HDR Ir-192 and the Asan Medical Center experience. Total 28 EBBT in 9 patients were performed since November 1989 and 24 EBBT in 8 patients were employed for palliation and 3 EBBT in 1 patient was treated curatively. Authors observed a significant relief of obstructive symptom with tumor regression in 7 patients out of 8 who were treated palliatively but one of them died of pulmonary congestion in 3 weeks after EBBT. One patient with prior therapy of extensive electrocautery expired within 1 day after 2nd EBBT procedure with massive hemorrhage from the lesion. EBBT procedure has been tolerable and can be performed as an outpatient

  10. FEATURES OF CONTROLLING ELECTROPNEUMATIC VALVES OF ACTUATOR TO CONTROL ITS CLUTCH WITH ACCELERATION VALVE

    Directory of Open Access Journals (Sweden)

    O. A. Yaryta

    2018-01-01

    Full Text Available The article deals with one of the ways to control an actuator of the automated clutch control system. The aim is to design control of the electropneumatic actuator, to control its coupling with the acceleration valve on the basis of experimental research as well as to provide rational parameters of the automated clutch control system for the robotic transmission. The feature of the system is an acceleration valve in the design of the electropneumatic actuator to control the clutch. New links demand to adjust the way to control the actuator. The connection of Pulse-Width Modulation (PWM with single power supply pulses to control electropneumatic valves is substantiated. The quantitative characteristics of single control pulses and PWM ones are determined. The error of operation accuracy for various ways of the control of the electropneumatic actuator to control the clutch of the robotic transmission is determined. Obtained separate PWM area is designed to suppress the initial hysteresis when the rod of the clutch actuator is moved. An algorithm for the operation of a clutch control system is proposed, taking into account the use of two modes of operation of solenoid valves. A graphical interpretation of the clutch control algorithm is presented, which gives an idea of the location of the constant signal feeding zones to the solenoid valve, as well as the operation areas of the solenoid valve in PWM mode. The control algorithm of the clutch booster provides a mode of guaranteed absence of excess pressure in the pneumatic cylinder after releasing the clutch pedal, provided that two normally closed solenoid valves are used. This configuration of the electro-pneumatic clutch control system allows the use of an emergency clutch release system in case of voltage absence. The reference algorithm for filtering the array of data coming from the feedback sensor, as well as the numerical values of the delay caused by the presence of a filter, are given.

  11. An infrequent cause of total lung collapse: Endobronchial lipoma

    African Journals Online (AJOL)

    Fahd Ahmed Suhail

    2014-06-21

    Jun 21, 2014 ... investigation revealed that the tumor was an endobronchial lipoma; the tumor composed of mature ... fever, shortness of breath, weight loss, or other associated ... circumscribed, soft, yellow masses ranging in size from 1 to.

  12. Endobronchial Electrocautery Using Snare

    Directory of Open Access Journals (Sweden)

    Masaaki Kawahara

    1996-01-01

    Full Text Available Between May 1987 and March 1994, upper airway and tracheobronchial electrosurgery with snare was performed in 13 patients (10 men and 3 women, ranging in age from 18 to 87 years. Four patients had benign lesions, and nine had malignant tumors. Total eradication has been achieved in the two patients with benign lesions. Electroexcision of the endobronchial portion of the tumor helped to clear the respiratory airways in all cases with malignant tumors. There has been no major side effects such as bleeding due to this method. Electrocautery is an available economical tool, which helps to diagnose and treat obstructing airway mass lesions.

  13. Combined atresia of one left-sided and one right-sided cardiac valve in a premature newborn.

    Science.gov (United States)

    Roberts, William C; Sing, Alan C; Guileyardo, Joseph M

    2017-10-01

    Described herein is the heart of a 2-day-old newborn, the product of a 25-week gestation, with atresia of two cardiac valves, one on the right side and one on the left side, apparently a previously undescribed entity.

  14. Radiologic observation of endobronchial tuberculosis in adults

    International Nuclear Information System (INIS)

    Lee, Kyung Yun; Lee, Min Jeong; Lee, Chang Joon; Kim, Han Seok

    1988-01-01

    Tuberculous involvement of the tracheobronchial tree usually coexists with active pulmonary parenchymal or intrathoracic lymph node infection and very rarely has been showed normal chest roentgenograms. This paper described 30 cases of endobronchial tuberculosis, confirmed by bronchoscopy and biopsy in correlation to bronchographic finding on the patients from Jan. 1993 to Nov. 1986 in Department of Radiology, National Medical Center. The results were as follows; 1. Sex distribution of endobronchial tuberculosis showed 8 cases (26.7%), moderately advanced pulmonary tuberculosis 4 cases (13.3%), far advanced pulmonary tuberculosis 2 cases (6.7%), and normal finding 1 case (3.3%). 3. 25 cases of 28 bronchogram showed bronchial obstruction. The left side was affected slightly more than the right (14:11). 4. The obstruction site of bronchus showed complete obstruction in 11 cases, among them shape cut off in 2, rat tail narrowing in 1, symmetrical V-shaped narrowing in 8, and incomplete obstruction in 14 cases, among them thumb printing indentation in 2, circumferential symmetrical narrowing in 12. 5. 10 cases of 25 obstruction showed an associated bronchiectatic change of distal of adjacent to the lesion site, among them tubular in 3, saccular in 2, cystic in 5 cases.

  15. A rare case of fibrostenotic endobronchial tuberculosis of trachea

    Directory of Open Access Journals (Sweden)

    Cassiopia Cary

    2015-12-01

    Full Text Available Endobronchial tuberculosis (EBTB is a sequelae of pulmonary tuberculosis (TB that extends to the endobronchial or endotracheal wall causing inflammation, edema, ulceration, granulation or fibrosis of mucosa and submucosa. This case depicts a 20 year old foreign-born woman with a history of active pulmonary TB on anti-TB chemotherapy, who presented with worsening stridor, dyspnea, cough and weight loss. The disease state was diagnosed with multiple modalities including, spirometry, CT scan of the neck, and bronchoscopy. The biopsies of the tracheal web revealed fibrotic tissue without any granulomas or malignancy establishing the diagnosis of EBTB. Serial balloon dilations and anti-neoplastic therapy with Mitomycin C was used to accomplish sufficient airway patency to relieve her symptoms. ETBT is a rare consequence of TB, which although has a low incidence in the United States, so physicians should have a high clinical suspicion based on the need for prompt intervention.

  16. Detection of an embolized central venous catheter fragment with endobronchial ultrasound.

    Science.gov (United States)

    Dhillon, Samjot Singh; Harris, Kassem; Alraiyes, Abdul H; Picone, Anthony L

    2018-01-01

    An 84-year-old woman underwent Convex-probe Endobronchial Ultrasound (CP-EBUS) for 18 F-fluorodeoxyglucose avid subcarinal lymphadenopathy on Positron Emission Tomogram (PET) scan. Endobronchial ultrasound-guided transbronchial needle aspiration of the subcarinal lymph node revealed squamous cell lung carcinoma. A small hyperechoic rounded density was noted inside the lumen of the azygous vein. Based on chest computed tomography findings and her clinical history, this was felt to be a broken fragment of a peripherally inserted central catheter, which was placed for intravenous antibiotics, a few months prior to this presentation. To the best of our knowledge, this is the first ever CP-EBUS description of a broken fragment of central venous catheter. © 2016 John Wiley & Sons Ltd.

  17. Primary endobronchial marginal zone B-cell lymphoma of bronchus-associated lymphoid tissue: CT findings 7 patients

    International Nuclear Information System (INIS)

    Yoon, Ra Gyoung; Kim, Mi Young; Song, Jae Woo; Chae, Eun Jin; Choi, Chang Min; Jang, Se Jin

    2013-01-01

    To investigate CT and 1 8F -fluorodeoxyglucose (1 8F -FDG) positron-emission tomography/CT findings of primary endobronchial marginal zone B-cell lymphoma of the bronchus-associated lymphoid tissue (BALT). From June 2006 through April 2012, seven patients (six female, one male; age range, 21-61 years; mean age, 49 years) were examined who were pathologically diagnosed with the primary endobronchial marginal zone B-cell lymphoma of BALT. We evaluated the locations and characteristics of the lesions on CT and 1 8F -FDG-PET/CT scans. The lesions were classified into the following three patterns: 1) solitary intraluminal nodule; 2) several tiny nodular protrusions; and 3) diffuse wall thickening. A solitary intraluminal nodule was observed in four patients (57.1%), several tiny nodular protrusion in two patients (28.6%), and diffuse wall thickening in one patient (14.3%). The lesions were categorized into 3 major locations: confined to the trachea (n 3), confined to the lobar bronchus (n = 2), and diffuse involvement of the trachea and both main bronchi (n = 2). All lesions demonstrated homogeneous iso-attenuation as compared with muscle on pre- and post-enhancement scans. Secondary findings in the lungs (n = 3; 42.9%) included postobstructive lobar atelectasis (n = 1), air trapping (n = 1), and pneumonia (n = 1). On 1 8F -FDG-PET/CT (n = 5), 4 lesions showed homogeneous uptake with maximum standardized uptake values (mSUV), ranging 2.3-5.7 (mean mSUV: 3.3). One lesion showed little FDG uptake. Primary endobronchial marginal zone B-cell lymphoma of the BALT manifests as three distinct patterns on CT, with the solitary intraluminal nodule presenting as the main pattern. Most lesions demonstrate homogeneous but weak FDG uptake on 1 8F -FDG-PET/CT.

  18. Primary endobronchial marginal zone B-cell lymphoma of bronchus-associated lymphoid tissue: CT findings 7 patients

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Ra Gyoung; Kim, Mi Young; Song, Jae Woo; Chae, Eun Jin; Choi, Chang Min; Jang, Se Jin [University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2013-04-15

    To investigate CT and 1{sup 8F}-fluorodeoxyglucose (1{sup 8F}-FDG) positron-emission tomography/CT findings of primary endobronchial marginal zone B-cell lymphoma of the bronchus-associated lymphoid tissue (BALT). From June 2006 through April 2012, seven patients (six female, one male; age range, 21-61 years; mean age, 49 years) were examined who were pathologically diagnosed with the primary endobronchial marginal zone B-cell lymphoma of BALT. We evaluated the locations and characteristics of the lesions on CT and 1{sup 8F}-FDG-PET/CT scans. The lesions were classified into the following three patterns: 1) solitary intraluminal nodule; 2) several tiny nodular protrusions; and 3) diffuse wall thickening. A solitary intraluminal nodule was observed in four patients (57.1%), several tiny nodular protrusion in two patients (28.6%), and diffuse wall thickening in one patient (14.3%). The lesions were categorized into 3 major locations: confined to the trachea (n 3), confined to the lobar bronchus (n = 2), and diffuse involvement of the trachea and both main bronchi (n = 2). All lesions demonstrated homogeneous iso-attenuation as compared with muscle on pre- and post-enhancement scans. Secondary findings in the lungs (n = 3; 42.9%) included postobstructive lobar atelectasis (n = 1), air trapping (n = 1), and pneumonia (n = 1). On 1{sup 8F}-FDG-PET/CT (n = 5), 4 lesions showed homogeneous uptake with maximum standardized uptake values (mSUV), ranging 2.3-5.7 (mean mSUV: 3.3). One lesion showed little FDG uptake. Primary endobronchial marginal zone B-cell lymphoma of the BALT manifests as three distinct patterns on CT, with the solitary intraluminal nodule presenting as the main pattern. Most lesions demonstrate homogeneous but weak FDG uptake on 1{sup 8F}-FDG-PET/CT.

  19. Using virtual-reality simulation to assess performance in endobronchial ultrasound

    DEFF Research Database (Denmark)

    Konge, Lars; Annema, Jouke; Clementsen, Paul

    2013-01-01

    For optimal treatment of patients with non-small cell lung carcinoma, it is essential to have physicians with competence in endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). EBUS training and certification requirements are under discussion and the establishment of basi...

  20. [Surgical Treatment of Bronchial Stricture due to Endobronchial Tuberculosis: 
Results in 36 Consecutive Cases].

    Science.gov (United States)

    Ruan, Junzhong; Zhang, Tianhui; Li, Fugen; Duan, Yong; Han, Ming; Wang, Zitong

    2018-04-20

    Bronchial tuberculosis is a common complication of pulmonary tuberculosis. The present report is to investigate and analyze the indication and efficacy of surgical treatment of bronchial stricture due to severe endobronchial tuberculosis, when the drug and endoscopic treatment were no effect. Reviewed the clinical-pathological records documenting the surgical outcomes in 36 bronchial stricture due to severe endobronchial tuberculosis who underwent lobectomy or pneumonectomy enrolled in our hospital between January 2000 and February 2016. Pneumonectomy in 8 cases, lobectomy in 23 cases, sleeve resection in 5 cases. No intraoperative or early postoperative death occurred. Six patients developed complications. All 6 cases recovered well after treatment. Surgical treatment is still the recommended treatment modatity for bronchial stricture caused by endobronchial tuberculosis due to its good results. It should be performed in time when the drug and intraluninal treatment were no effect for avoiding of being progeressed.

  1. Usefulness of FDG PET/CT in determining benign from malignant endobronchial obstruction

    International Nuclear Information System (INIS)

    Cho, Arthur; Kang, Won Jun; Cho, Ho Jin; Lee, Jae-hoon; Yun, Mijin; Lee, Jong Doo; Hur, Jin

    2011-01-01

    To evaluate the usefulness of FDG PET/CT to differentiate malignant endobronchial lesions with distal atelectasis from benign bronchial stenosis. This retrospective study reviewed 84 patients who underwent contrast-enhanced chest CT and then PET/CT and had histological (n = 81) or follow-up imaging (n = 3) confirmation. Two chest radiologists reviewed initial chest CT and determined endobronchial lesions to be malignant or benign. Two nuclear medicine physicians reviewed PET/CT for FDG uptake at the obstruction site and measured SUV. Malignancy was considered when increased FDG uptake was seen in the obstruction site, regardless of FDG within the atelectatic lung. The sensitivity, specificity and accuracy of chest CT was 95%, 48% and 84%, compared with 95%, 91% and 94% for PET/CT. Benign obstructive lesions showed statistically lower FDG uptake than malignant obstructions (benign SUV 2.5 ± 0.84; malignant SUV 11.8 ± 5.95, p < 0.001). ROC analysis showed an SUV cut-off value of 3.4 with highest sensitivity of 94% and specificity of 91%. Increased FDG PET/CT uptake at the obstruction site indicates a high probability of malignancy, while benign lesions show low FDG uptake. Careful evaluation of FDG uptake pattern at the obstruction site is helpful in the differentiation between benign and malignant endobronchial lesions. (orig.)

  2. Usefulness of FDG PET/CT in determining benign from malignant endobronchial obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Arthur; Kang, Won Jun; Cho, Ho Jin; Lee, Jae-hoon; Yun, Mijin; Lee, Jong Doo [Yonsei University Health System, Division of Nuclear Medicine, Department of Radiology, Seoul (Korea, Republic of); Hur, Jin [Yonsei University Health System, Department of Radiology, Seoul (Korea, Republic of)

    2011-05-15

    To evaluate the usefulness of FDG PET/CT to differentiate malignant endobronchial lesions with distal atelectasis from benign bronchial stenosis. This retrospective study reviewed 84 patients who underwent contrast-enhanced chest CT and then PET/CT and had histological (n = 81) or follow-up imaging (n = 3) confirmation. Two chest radiologists reviewed initial chest CT and determined endobronchial lesions to be malignant or benign. Two nuclear medicine physicians reviewed PET/CT for FDG uptake at the obstruction site and measured SUV. Malignancy was considered when increased FDG uptake was seen in the obstruction site, regardless of FDG within the atelectatic lung. The sensitivity, specificity and accuracy of chest CT was 95%, 48% and 84%, compared with 95%, 91% and 94% for PET/CT. Benign obstructive lesions showed statistically lower FDG uptake than malignant obstructions (benign SUV 2.5 {+-} 0.84; malignant SUV 11.8 {+-} 5.95, p < 0.001). ROC analysis showed an SUV cut-off value of 3.4 with highest sensitivity of 94% and specificity of 91%. Increased FDG PET/CT uptake at the obstruction site indicates a high probability of malignancy, while benign lesions show low FDG uptake. Careful evaluation of FDG uptake pattern at the obstruction site is helpful in the differentiation between benign and malignant endobronchial lesions. (orig.)

  3. The Heimlich Valve for Pleural Cavity Drainage | Makanga | Annals ...

    African Journals Online (AJOL)

    Introduction: Traditional chest tube fixation and drainage has been undertaken using standard rigid chest tubes connected to under water seal bottles. These are bulky, cumbersome, expensive, and pose a risk of accidental air suction into the chest. One-way valve systems such as the Heimlich valve are small, portable ...

  4. Toward endobronchial Ir-192 high-dose-rate brachytherapy therapeutic optimization

    International Nuclear Information System (INIS)

    Gay, H A; Allison, R R; Downie, G H; Mota, H C; Austerlitz, C; Jenkins, T; Sibata, C H

    2007-01-01

    A number of patients with lung cancer receive either palliative or curative high-dose-rate (HDR) endobronchial brachytherapy. Up to a third of patients treated with endobronchial HDR die from hemoptysis. Rather than accept hemoptysis as an expected potential consequence of HDR, we have calculated the radial dose distribution for an Ir-192 HDR source, rigorously examined the dose and prescription points recommended by the American Brachytherapy Society (ABS), and performed a radiobiological-based analysis. The radial dose rate of a commercially available Ir-192 source was calculated with a Monte Carlo simulation. Based on the linear quadratic model, the estimated palliative, curative and blood vessel rupture radii from the center of an Ir-192 source were obtained for the ABS recommendations and a series of customized HDR prescriptions. The estimated radius at risk for blood vessel perforation for the ABS recommendations ranges from 7 to 9 mm. An optimized prescription may in some situations reduce this radius to 4 mm. The estimated blood perforation radius is generally smaller than the palliative radius. Optimized and individualized endobronchial HDR prescriptions are currently feasible based on our current understanding of tumor and normal tissue radiobiology. Individualized prescriptions could minimize complications such as fatal hemoptysis without sacrificing efficacy. Fiducial stents, HDR catheter centering or spacers and the use of CT imaging to better assess the relationship between the catheter and blood vessels promise to be useful strategies for increasing the therapeutic index of this treatment modality. Prospective trials employing treatment optimization algorithms are needed

  5. A randomized controlled trial of electrocoagulation-enabled biopsy versus conventional biopsy in the diagnosis of endobronchial lesions.

    Science.gov (United States)

    Khan, Ajmal; Aggarwal, Ashutosh N; Agarwal, Ritesh; Bal, Amanjit; Gupta, Dheeraj

    2011-01-01

    Although electrocoagulation at time of endobronchial biopsy can potentially reduce procedure-related bleeding during fiberoptic bronchoscopy (FOB), it can also impair quality of tissue specimen; credible data for either are lacking. To evaluate the impact of hot biopsy on the quality of tissue samples and to quantify the amount of procedure-related bleeding during endobronchial biopsy. In this single-center, prospective, single-blind, randomized controlled study we included adult patients referred for FOB and having endobronchial lesions. Patients were randomized to bronchial biopsy using an electrocoagulation-enabled biopsy forceps, with (EC+ group) or without (EC- group) application of electrocoagulation current (40 W for 10 s in a monopolar mode). Procedure-related bleeding was semi-quantified by observer description, as well as through a visual analogue scale. Overall quality of biopsy specimen and tissue damage were assessed and graded by a pulmonary pathologist blinded to FOB details. 160 patients were randomized to endobronchial biopsy with (n = 81) or without (n = 79) the application of electrocoagulation. There were no severe bleeding episodes in either group, and severity of bleeding in the EC+ and EC- groups was similar (median visual analogue scale scores of 14 and 16, respectively). Histopathological diagnosis was similar in the EC+ and EC- groups (77.8% and 82.3%, respectively). There was no significant difference in tissue quality between the two groups. Use of electrocoagulation-enabled endobronchial biopsy does not alter specimen quality and does not result in any significant reduction in procedure-related bleeding. Copyright © 2010 S. Karger AG, Basel.

  6. Side effects of endobronchial laser treatment

    Energy Technology Data Exchange (ETDEWEB)

    Dierkesmann, R.; Huzly, A.

    1985-03-01

    Side effects that have occurred in over 250 endobronchial laser treatments are reported. The laser has been used in severe tracheal and in bronchial obstructions. In two cases significant bleeding had to be treated with tamponade. In one patient an emphysema of the mediastinum developed, in 2 further patients a small pneumothorax. Perforation of the airway was not detected and no special treatment was necessary. Three patients with life-threatening tracheal stenoses and one patient with severe stenosis of both the mainstem bronchi due to metastasis in the bifurcation lymph node had a large defect in the tracheal or bronchial wall with a deep necrosis five to twelve weeks after laser treatment; all these patients had extensive radiotherapy in addition. One patient died due to severe respiratory insufficiency, probably caused by smoke intoxication. After the laser treatment, rubber-like fibrin-rich plaques may develop, which can lead to life-threatening obstructions of the airway. It is recommended that laser bronchoscopy should be performed with the rigid bronchoscope. After treatment of tracheal lesion an endoscopic check must be performed within 24 hours. The combination of laser treatment and radiotherapy seems to involve a certain risk of large defects in the bronchial wall due to necrosis of the tumor.

  7. Discomfort during bronchoscopy performed after endobronchial intubation with fentanyl and midazolam: a prospective study.

    Science.gov (United States)

    Minami, Daisuke; Takigawa, Nagio; Kano, Hirohisa; Ninomiya, Takashi; Kubo, Toshio; Ichihara, Eiki; Ohashi, Kadoaki; Sato, Akiko; Hotta, Katsuyuki; Tabata, Masahiro; Tanimoto, Mitsune; Kiura, Katsuyuki

    2017-05-01

    Although endobronchial intubation during a bronchoscopic examination is useful for invasive procedures, it is not routine practice in Japan. The present study evaluated discomfort due to endobronchial intubation using fentanyl and midazolam sedation during bronchoscopy. Thirty-nine patients were enrolled prospectively from November 2014 to September 2015 at Okayama University Hospital. Fentanyl (20 µg) was administered to the patients just before endobronchial intubation, and fentanyl (10 µg) and midazolam (1 mg) were added as needed during the procedure. A questionnaire survey was administered 2 h after the examination. In the questionnaire, patient satisfaction was scored using a visual analog scale as follows: excellent (1 point), good (2 points), normal (3 points), uncomfortable (4 points) and very uncomfortable (5 points). An additional question ('Do you remember the bronchoscopic examination?') was also asked. Predefined parameters (blood pressure, heart rate, oxygen saturation and complications) were recorded. The enrolled patients included 22 males and 17 females; their median age was 70 (range: 28-88) years. The patients received a mean dose of 47.9 µg of fentanyl (range: 30-90 µg) and 2.79 mg of midazolam (range: 1-7 mg). In total, 28 patients (71.7%) agreed to undergo a second bronchoscopic examination; the mean levels of discomfort and for the re-examination were 2.07 points each. About 41% of the patients remembered the bronchoscopic examination. No severe complications were reported. Endobronchial intubation using fentanyl and midazolam sedation during an invasive bronchoscopic procedure might be recommended. UMIN000015578 in the UMIN Clinical Trials Registry. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  8. Design of the Modular Pneumatic Valve Terminal

    Directory of Open Access Journals (Sweden)

    Jakub E. TAKOSOGLU

    2015-11-01

    Full Text Available The paper presents design of the modular pneumatic valve terminal, which was made on the basis of the patent application No A1 402905 „A valve for controlling fluid power drives, specially for pneumatic actuators, and the control system for fluid power drives valves”. The authors describe a method of operation of the system with double-acting valve and 5/2 (five ways and two position valve. Functions of the valve, and an example of application of the valve terminal in the production process were presented. 3D solid models of all the components of the valve were made. The paper presents a complete 3D model of the valve in various configurations. Using CAD-embedded SOLIDWORKS Flow Simulation computational fluid dynamics CFD analysis was also carried out of compressed air flow in the ways of the valve elements

  9. Incidence of mitral valve prolapse in one hundred clinically stable newborn baby girls: an echocardiographic study.

    Science.gov (United States)

    Chandraratna, P A; Vlahovich, G; Kong, Y; Wilson, D

    1979-09-01

    Clinical and echocardiographic examinations were performed on 100 clinically stable, newborn baby girls. Mitral valve prolapse was noted on the echocardiograms of seven babies. Three subjects had systolic clicks, two of whom had systolic murmurs following the click. The four other babies who had echocardiographic evidence of mitral valve prolapse had no abnormal auscultatory signs. Of the 93 babies without evidence of mitral prolapse, 91 had normal echocardiograms and auscultatory features; one was noted to have a murmur consistent with a ventricular septal defect, and another had an eccentric aortic valve on the echocardiogram which was suggestive of a bicuspid aortic valve. Serial studies on our group of subjects will yield useful information regarding the natural history of mitral valve prolapse.

  10. VALVULAR BRONCHIAL BLOCKING IN TREATMENT OF RELAPSING SPONTANEOUS PHEUMOTHORAX IN THE PATIENT WITH PARASEPTAL PULMONARY EMPHYSEMA

    Directory of Open Access Journals (Sweden)

    O. V. Lovacheva

    2014-01-01

    Full Text Available Spontaneous pneumothorax was treated by placing two endobronchial valves during rigid bronchoscopy under anesthesia in a patient with severe end-stage chronic obstructive pulmonary disease (an emphysematous phenotype and overall paraseptal emphysema in the presence of grade III respiratory failure, with complicated spontaneous pneumothorax recurring manifold even after surgical treatment for spontaneous pneumothorax. This gave rise to the expansion of the lung that had collapsed within 18 months, to healing of bronchopleural fistula, and to return to normal life.The duration of a follow-up was 1 year with the valves being present in the bronchi and another year after their removal; there was no recurrence of spontaneous pneumothorax. Examination of respiratory function established significant positive changes (forced expiratory volume, vital capacity, and forced vital capacity after one year, then after removal of endobronchial valves. There were more significant positive changes in blood gas composition: normalization of blood oxygen saturation was achieved. 

  11. Cyclonic valve test: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Andre Sampaio; Moraes, Carlos Alberto C.; Marins, Luiz Philipe M.; Soares, Fabricio; Oliveira, Dennis; Lima, Fabio Soares de; Airao, Vinicius [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil); Ton, Tijmen [Twister BV, Rijswijk (Netherlands)

    2012-07-01

    For many years, the petroleum industry has been developing a valve that input less shear to the flow for a given required pressure drop and this can be done using the cyclonic concept. This paper presents a comparison between the performances of a cyclonic valve (low shear) and a conventional globe valve. The aim of this work is to show the advantages of using a cyclonic low shear valve instead of the commonly used in the primary separation process by PETROBRAS. Tests were performed at PETROBRAS Experimental Center (NUEX) in Aracaju/SE varying some parameters: water cut; pressure loss (from 4 kgf/cm2 to 10 kgf/cm2); flow rates (30 m3/h and 45 m3/h). Results indicates a better performance of the cyclonic valve, if compared with a conventional one, and also that the difference of the performance, is a function of several parameters (emulsion stability, water content free, and oil properties). The cyclonic valve tested can be applied as a choke valve, as a valve between separation stages (for pressure drop), or for controlling the level of vessels. We must emphasize the importance to avoid the high shear imposed by conventional valves, because once the emulsion is created, it becomes more difficult to break it. New tests are being planned to occur in 2012, but PETROBRAS is also analyzing real cases where the applications could increase the primary process efficiency. In the same way, the future installations are also being designed considering the cyclonic valve usage. (author)

  12. Transcatheter aortic-valve implantation with one single minimal contrast media injection.

    Science.gov (United States)

    Arrigo, Mattia; Maisano, Francesco; Haueis, Sabine; Binder, Ronald K; Taramasso, Maurizio; Nietlispach, Fabian

    2015-06-01

    Performing transcatheter aortic valve implantation (TAVI) with the use of minimal contrast in patients at high-risk for acute kidney injury (AKI). Contrast-induced nephropathy (CIN) is a major cause of AKI following TAVI and is associated with increased morbidity and mortality. The amount of contrast media used increases the risk for CIN. Computed tomography was omitted during the screening process. For the procedure transfemoral access was default. The self-expanding CoreValve prosthesis was chosen in all patients to minimize the risk of annular rupture in case of oversizing. Valve sizing was based on echocardiography, aortography, calcification on fluoroscopy, as well as weight and height of the patient. A single contrast injection was performed to confirm correct position of the pigtail catheter at the level of the annulus. The pigtail then served as the marker for the device landing zone. Intraprocedural assessment of the implantation result relied on echocardiography and hemodynamics. Five patients with severe aortic stenosis and at high risk for developing CIN were included. Device success was achieved in all patients and no major complications occurred. The median dose of injected contrast media was 8 ml (4-9). All but one patient had improved renal function after the intervention compared to baseline. Our study shows feasibility of performing TAVI with a single minimal contrast media injection, using a self-expandable valve. This technique has the potential to reduce the incidence of CIN. © 2015 Wiley Periodicals, Inc.

  13. Reappraisal of the role of endobronchial brachytherapy in the management of lung cancer: 10 years' experience at the centre Antoine-Lacassagne

    International Nuclear Information System (INIS)

    Magne, N.; Benezery, K.; Marcie, S.; Lagrange, J.L.; Porsin, B.; Poudenx, M.; Otto, J.; Marcy, P.Y.; Benezery, K.; Lagrange, J.L.

    2003-01-01

    Intra-operative interstitial brachytherapy has been applied in the curative and palliative treatment of lung cancer. Implantation of radio-active sources offers an advantage over external irradiation because of the limited penetrability from source to prescription point, resulting in rapid dose fall-off and sparing of surrounding normal tissues. The aim of this study was to re-evaluate retrospectively the Antoine-Lacassagne cancer center experience in endobronchial brachytherapy by low dose rate (LDR) or high dose rate (HDR) and to design perspectives for the next decades. Evaluation was based on analysis of toxicities, response rates and survival. Materials and methods: From october 1989 to june 1999, 31 consecutive patients with bronchogenic carcinoma were treated. Thirteen and 18 patients received LDR and HDR, respectively. The mean age was 65 years (range 44 to 79 years). Inclusion criteria were, for palliative treatment, incurable endobronchial cancer, and for curative treatment, residual tumor in the margins after resection, or endobronchial tumor could not be treated surgically. Exclusion criteria were sites of lesion unsuitable for placement of the brachytherapy catheter. Evaluation of complications and clinical response were based on endoscopic evaluation one month after the last session and at less one year after the end of treatment. Eighty-seven courses have been performed: 65 by LDR and 22 by HDR. Thirty-six courses have been performed in the palliative group, 51 courses in the curative group. Seven patients among 31 presented acute complications and 18/31 late complications. Complete global response rate was 14/30 evaluable patients (47%). Mean overall Global survival was 23 months with a median follow-up of 3.5 years. These results confirm the efficacy of endobronchial brachytherapy as well as palliative or curative treatment, but the improvement of results will essentially depend on our capacity to better define our indications and underlie the

  14. Corrosion of valve metals

    International Nuclear Information System (INIS)

    Draley, J.E.

    1976-01-01

    A general survey related to the corrosion of valve metals or film-forming metals. The way these metals corrode with some general examples is described. Valve metals form relatively perfect oxide films with little breakdown or leakage when anodized

  15. A comparison of the disconnection technique with continuous bronchial suction for lung deflation when using the Arndt endobronchial blocker during video-assisted thoracoscopy: A randomised trial.

    Science.gov (United States)

    El-Tahan, Mohamed R

    2015-06-01

    The use of the Arndt endobronchial blocker has not gained widespread acceptance during video-assisted thoracoscopic surgery (VATS) because of its high cost and longer time to operative lung collapse especially in patients with chronic obstructive pulmonary disease (COPD). The use of a ventilator disconnection technique has been shown to produce a comparable degree of lung collapse when used with either a double-lumen tube or an Arndt endobronchial blocker. We hypothesised that the use of bronchial suction through the suction port of the endobronchial blocker would be associated with a comparable time to achieve optimum lung collapse as the disconnection technique. A randomised, double-blind study. Single university hospital. Fifty-eight patients with spontaneous pneumothorax scheduled for elective VATS using the Arndt endobronchial blocker for one-lung ventilation (OLV). Patients were randomly assigned to one of two groups (n = 29 per group) to deflate the operative lung with either disconnection of the endotracheal tube from the ventilator for 60 s prior to inflation of the endobronchial blocker or connection of a suction pressure of -30 cmH2O to the suction port of the endobronchial blocker through the barrel of a 1 ml syringe. The primary outcome was the time to total lung collapse. Secondary outcomes included surgeon rating of lung collapse, overall surgeon satisfaction, need for further fibreoptic bronchial suction manoeuvres and intraoperative hypoxaemia. The bronchial suction technique was associated with a significantly shorter time to total lung collapse than the disconnection method [93 (95% confidence interval, 95% CI 81.3 to 103.7) vs. 197 (95% CI 157.4 to 237) s respectively; P < 0.001]. Both the disconnection and bronchial suction groups had a comparable surgical rating of excellent lung collapse 40 min after the start of OLV (65.5 vs. 79.3%, respectively; P = 0.24), overall surgeon satisfaction [median (interquartile range, IQR) 9 (8 to 10) vs. 9 (8

  16. Lung perfusion and emphysema distribution affect the outcome of endobronchial valve therapy

    Directory of Open Access Journals (Sweden)

    Thomsen C

    2016-06-01

    Full Text Available Christian Thomsen,1 Dorothea Theilig,2 Dominik Herzog,1 Alexander Poellinger,2 Felix Doellinger,2 Nils Schreiter,3 Vera Schreiter,2 Dirk Schürmann,1 Bettina Temmesfeld-Wollbrueck,1 Stefan Hippenstiel,1 Norbert Suttorp,1 Ralf-Harto Hubner1 1Department of Internal Medicine/Infectious Diseases and Respiratory Medicine, 2Institute of Radiology, 3Institute of Nuclear Medicine, Charité – Universitätsmedizin Berlin, Berlin, Germany Abstract: The exclusion of collateral ventilation (CV and other factors affect the clinical success of endoscopic lung volume reduction (ELVR. However, despite its benefits, the outcome of ELVR remains difficult to predict. We investigated whether clinical success could be predicted by emphysema distribution assessed by computed tomography scan and baseline perfusion assessed by perfusion scintigraphy. Data from 57 patients with no CV in the target lobe (TL were retrospectively analyzed after ELVR with valves. Pulmonary function tests (PFT, St George’s Respiratory Questionnaire (SGRQ, and 6-minute walk tests (6MWT were performed on patients at baseline. The sample was grouped into high and low levels at the median of TL perfusion, ipsilateral nontarget lobe (INL perfusion, and heterogeneity index (HI. These groups were analyzed for association with changes in outcome parameters from baseline to 3 months follow-up. Compared to baseline, patients showed significant improvements in PFT, SGRQ, and 6MWT (all P≤0.001. TL perfusion was not associated with changes in the outcome. High INL perfusion was significantly associated with increases in 6MWT (P=0.014, and high HI was associated with increases in forced expiratory volume in 1 second (FEV1, (P=0.012. Likewise, there were significant correlations for INL perfusion and improvement of 6MWT (r=0.35, P=0.03 and for HI and improvement in FEV1 (r=0.45, P=0.001. This study reveals new attributes that associate with positive outcomes for patient selection prior to ELVR

  17. Efficient Constructions for One-way Hash Chains

    National Research Council Canada - National Science Library

    Hu, Yih-Chun; Jakobsson, Markus; Perrig, Adrian

    2003-01-01

    .... Our first construction, the Sandwich-chain, provides a smaller bandwidth overhead for one-way chain values, and enables efficient verification of one-way chain values if the trusted one-way chain value is far away...

  18. Performance of balanced bellows safety relief valves

    International Nuclear Information System (INIS)

    Lai, Y.S.

    1992-01-01

    By the nature of its design, the set point and lift of a conventional spring loaded safety relief valve are sensitive to back pressure. One way to reduce the adverse effects of the back pressure on the safety relief valve function is to install a balanced bellows in a safety relief valve. The metallic bellows has a rather wide range of manufacturing tolerance which makes the design of the bellows safety relief valve very complicated. The state-of-the-art balanced bellows safety relief valve can only substantially minimize, but cannot totally eliminate the back pressure effects on its set point and relieving capacity. Set point change is a linear function of the back pressure to the set pressure ratio. Depending on the valve design, the set point correction factor can be either greater or smaller than unity. There exists an allowable back pressure and critical back pressure for each safety relief valve. When total back pressure exceeds the R a , the relieving capacity will be reduced mainly resulting from the valve lift being reduced by the back pressure and the capacity reduction factor should be applied in valve sizing. Once the R c is exceeded, the safety relief valve becomes unstable and loses its over pressure protection capability. The capacity reduction factor is a function of system overpressure, but their relationship is non-linear in nature. (orig.)

  19. Modal-Based Design Improvement of a Butterfly Valve Disc

    Directory of Open Access Journals (Sweden)

    Marius Draghiciu

    2017-11-01

    Full Text Available The dynamic behaviour control of a butterfly valve is important because, when one of the valve disc natural frequency is close to the frequency of vortex shedding, which appears when the valve is fully open or partially closed, resonance may appear and vibration with significant amplitudes is generated. This paper presents an example by how the design of a butterfly valve disc can be improved by using a modal analysis performed by means of the finite element method. For this purpose, the research reveals the way in which the natural frequencies of the disc can be modified by applying stiffening ribs or changing the dimensions, respective the position of these ribs.

  20. Multifunctional four-port directional control valve constructed from logic valves

    International Nuclear Information System (INIS)

    Lisowski, E.; Czyżycki, W.; Rajda, J.

    2014-01-01

    Highlights: • Directional valve with standard ISO 440-08 has been constructed from logic valves. • Only one innovative valve may replace whole family of the standard valves. • CFD analysis and bench tests of the innovative valve has been carried. • Parameters of the innovative valve are equaling or surpassing the standard ones. • The innovative valve has additional possibilities of pressure and flow control. - Abstract: The paper refers to four-port solenoid pilot operated valves, which are subplate mounted in a hydraulic system in accordance with the ISO 4401 standard. Their widespread use in many machines and devices causes a continuing interest in the development of their design by both the scientific centers and the industry. This paper presents an innovative directional control valve based on the use of logic valves and a methodology followed for the design of it by using Solid Edge CAD and ANSYS/Fluent CFD software. The valve design methodology takes into account the need to seek solutions that minimize flow resistance through the valve. For this purpose, the flow paths are prepared by means of CAD software and pressure-flow curves are determined as a result of CFD analysis. The obtained curves are compared with the curves available in the catalogs of spool type directional control valves. The new solution allows to replace the whole family of spool type four-port directional control valves by one valve built of logic valves. In addition, the innovative directional control valve provides leak-proof shutting the flow paths off and also it can control flow rate and even pressure of working liquid. A prototype of the valve designed by the presented method has been made and tested on the test bench. The results quoted in the paper confirm that the developed logic type directional control valve is able to meet all designed connection configurations, and the obtained pressure-flow curves show very good conformity with the results of CFD analysis

  1. Restoration of Patency to Central Airways Occluded by Malignant Endobronchial Tumors Using Intratumoral Injection of Cisplatin.

    Science.gov (United States)

    Mehta, Hiren J; Begnaud, Abbie; Penley, Andrea M; Wynne, John; Malhotra, Paras; Fernandez-Bussy, Sebastian; Cope, Jessica; Shuster, Jonathan J; Jantz, Michael A

    2015-09-01

    Malignant airway obstruction is commonly found in patients with lung cancer and is associated with significant morbidity and mortality. Relieving malignant obstruction may improve symptoms, quality of life, and life expectancy. The objective of this study was to analyze our experience with bronchoscopic endobronchial intratumoral injection of cisplatin for malignant airway obstruction. We conducted a retrospective analysis of patients with malignant airway obstruction treated with bronchoscopic intratumoral injection of cisplatin. Patient characteristics, histology, degree of airway obstruction, procedural methods, treatment cycles, performance status, and therapeutic outcomes were evaluated. Tumor response was analyzed based on bronchoscopic measurements performed on completion the of final treatment session. Adverse events and overall survival were abstracted. Between January 2009 and September 2014, 22 patients (10 men, 12 women; mean age ± SD, 64.4 ± 9.5 yr) were treated with one to four injections of 40 mg of cisplatin mixed in 40 ml of 0.9% NaCl. Treatments were completed 1 week apart. The primary etiologies of airway obstruction included squamous cell carcinoma (n = 11), adenocarcinoma (n = 6), small cell carcinoma (n = 2), large cell undifferentiated carcinoma (n = 1), and metastatic endobronchial cancer (n = 2). Twenty-one of 22 patients were evaluable for response. The majority of patients (15/21, 71.4%) responded to therapy, defined as greater than 50% relative reduction in obstruction from baseline. Treatment response was obtained regardless of tumor histology, concurrent systemic therapy, number of treatment cycles administered, performance status, or use of additional ablative interventions. Responders had significantly improved overall survival as compared with nonresponders, although the difference was small. Severe treatment-related side effects or complications were not observed. Subject to the limitations of a single

  2. Insidious strut fractures in a DeBakey-Surgitool aortic valve prosthesis.

    Science.gov (United States)

    Scott, S M; Sethi, G K; Paulson, D M; Takaro, T

    1978-04-01

    Recent reports of cage wear occurring in DeBakey-Surgitool aortic valve prostheses prompted us to examine with image intensification all our patients who have had this type of prosthesis implanted. One patient, who was asymptomatic, was discovered to have a prosthesis with two fractured struts. This patient's prosthetic valve was replaced successfully with a stented porcine heterograft prosthesis. Including the valve removed from this patient, 8 DeBakey-Surgitool aortic valves with structural defects have been reported to the manufacturer. In the absence of a catastrophic event, patients with valves having fractured or worn struts may be totally asymptomatic, and routine periodic roentgenographic examination may be the only way of detecting strut wear or fracture.

  3. Comparative study of Butterfly valves

    International Nuclear Information System (INIS)

    Galmes Belmonte, F.B.

    1998-01-01

    This work tries to justify the hydrodynamic butterfly valves performance, using the EPRI tests, results carried out in laboratory and in situ. This justification will be possible if: - The valves to study are similar - Their performance is calculated using EPRI's methodology Looking for this objective, the elements of the present work are: 1. Brief EPRI butterfly valve description it wild provide the factors which are necessary to define the butterfly valves similarity. 2. EPRI tests description and range of validation against test data definition. 3. Description of the spanish butterfly analyzed valves, and comparison with the EPRI performance results, to prove that this valves are similar to the EPRI test valves. In this way, it will not be necessary to carry out particular dynamic tests on the spanish valves to describe their hydrodynamic performance. (Author)

  4. Automated electric valve for electrokinetic separation in a networked microfluidic chip.

    Science.gov (United States)

    Cui, Huanchun; Huang, Zheng; Dutta, Prashanta; Ivory, Cornelius F

    2007-02-15

    This paper describes an automated electric valve system designed to reduce dispersion and sample loss into a side channel when an electrokinetically mobilized concentration zone passes a T-junction in a networked microfluidic chip. One way to reduce dispersion is to control current streamlines since charged species are driven along them in the absence of electroosmotic flow. Computer simulations demonstrate that dispersion and sample loss can be reduced by applying a constant additional electric field in the side channel to straighten current streamlines in linear electrokinetic flow (zone electrophoresis). This additional electric field was provided by a pair of platinum microelectrodes integrated into the chip in the vicinity of the T-junction. Both simulations and experiments of this electric valve with constant valve voltages were shown to provide unsatisfactory valve performance during nonlinear electrophoresis (isotachophoresis). On the basis of these results, however, an automated electric valve system was developed with improved valve performance. Experiments conducted with this system showed decreased dispersion and increased reproducibility as protein zones isotachophoretically passed the T-junction. Simulations of the automated electric valve offer further support that the desired shape of current streamlines was maintained at the T-junction during isotachophoresis. Valve performance was evaluated at different valve currents based on statistical variance due to dispersion. With the automated control system, two integrated microelectrodes provide an effective way to manipulate current streamlines, thus acting as an electric valve for charged species in electrokinetic separations.

  5. Leakage characterization of a piloted power operated relief valve

    International Nuclear Information System (INIS)

    Ezekoye, L.I.; Hess, M.D.

    1995-01-01

    In Westinghouse Pressurized Water Reactors (PWRs), power operated relief valves (PORVs) are used to provide overpressure protection of the Pressurizer. The valves are fail closed globe valves which means that power is required to open the valves and, on loss of power, the valves close. There are two ways to operate the PORVs. The more common way is to directly couple the disc to an actuator via a disc-stem assembly. The type of design is not the object of this paper. The other and less common way of operating a PORV is by piloting the main valve such that the opening or closing of a pilot valve opens and closes the main valve. This is the design of interest. In most plants, the PORVs are installed with a water loop seal while in some plants no water loop seals are used. It is generally accepted that loop seal installation minimizes valve seat leakage. In non-loop seal installation, the valve seat is exposed to steam which increases the potential for seat leakage. This paper describes the results of some tests performed with nitrogen and steam to characterize the leakage potential of a pilot operated PORV. The test results were compared with seat leakage tests of check valves to provide insight on the leakage testing of pilot operated valves and check valves. The paper also compares the test data with leakage estimates using the ASME/ANSI OM Code guidance on valve leakage

  6. Results of combined photodynamic therapy (PDT) and high dose rate brachytherapy (HDR) in treatment of obstructive endobronchial non-small cell lung cancer

    Science.gov (United States)

    Weinberg, Benjamin D.; Allison, Ron R.; Sibata, Claudio; Parent, Teresa; Downie, Gordon

    2009-06-01

    We reviewed the outcome of combined photodynamic therapy (PDT) and high dose rate brachytherapy (HDR) for patients with symptomatic obstruction from endobronchial non-small cell lung cancer. Methods: Nine patients who received combined PDT and HDR for endobronchial cancers were identified and their charts reviewed. The patients were eight males and one female aged 52-73 at diagnosis, initially presenting with various stages of disease: stage IA (N=1), stage IIA (N=1), stage III (N=6), and stage IV (N=1). Intervention was with HDR (500 cGy to 5 mm once weekly for 3 weeks) and PDT (2 mg/kg Photofrin, followed by 200 J/cm2 illumination 48 hours post infusion). Treatment group 1 (TG-1, N=7) received HDR first; Treatment group 2 (TG-2, N=2) received PDT first. Patients were followed by regular bronchoscopies. Results: Treatments were well tolerated, all patients completed therapy, and none were lost to follow-up. In TG-1, local tumor control was achieved in six of seven patients for: 3 months (until death), 15 months, 2+ years (until death), 2+ years (ongoing), and 5+ years (ongoing, N=2). In TG-2, local control was achieved in only one patient, for 84 days. Morbidities included: stenosis and/or other reversible benign local tissue reactions (N=8); photosensitivity reaction (N=2), and self-limited pleural effusion (N=2). Conclusions: Combined HDR/PDT treatment for endobronchial tumors is well tolerated and can achieve prolonged local control with acceptable morbidity when PDT follows HDR and when the spacing between treatments is one month or less. This treatment regimen should be studied in a larger patient population.

  7. High-Dose-Rate Endobronchial Brachytherapy for Recurrent Airway Obstruction From Hyperplastic Granulation Tissue

    International Nuclear Information System (INIS)

    Tendulkar, Rahul D.; Fleming, Peter A.; Reddy, Chandana A.; Gildea, Thomas R.; Machuzak, Michael; Mehta, Atul C.

    2008-01-01

    Purpose: Benign endobronchial granulation tissue causes airway obstruction in up to 20% of patients after lung transplantation or stent placement. High-dose-rate endobronchial brachytherapy (HDR-EB) has been successful in some cases refractory to standard bronchoscopic interventions. Methods and Materials: Between September 2004 and May 2005, 8 patients with refractory benign airway obstruction were treated with HDR-EB, using one to two fractions of Ir-192 prescribed to 7.1 Gy at a radius of 1 cm. Charts were retrospectively reviewed to evaluate subjective clinical response, forced expiratory volume in 1 second (FEV 1 ), and frequency of therapeutic bronchoscopies over 6-month periods before and after HDR-EB. Results: The median follow-up was 14.6 months, and median survival was 10.5 months. The mean number of bronchoscopic interventions improved from 3.1 procedures in the 6-month pretreatment period to 1.8 after HDR-EB. Mean FEV 1 improved from 36% predicted to 46% predicted. Six patients had a good-to-excellent subjective early response, but only one maintained this response beyond 6 months, and this was the only patient treated with HDR-EB within 24 h from the most recent bronchoscopic intervention. Five patients have expired from causes related to their chronic pulmonary disease, including one from hemoptysis resulting from a bronchoarterial fistula. Conclusion: High-dose-rate-EB may be an effective treatment for select patients with refractory hyperplastic granulation tissue causing recurrent airway stenosis. Performing HDR-EB within 24-48 h after excision of obstructive granulation tissue could further improve outcomes. Careful patient selection is important to maximize therapeutic benefit and minimize toxicity. The optimal patient population, dose, and timing of HDR-EB should be investigated prospectively

  8. Combined endobronchial and esophageal endosonography for the diagnosis and staging of lung cancer

    DEFF Research Database (Denmark)

    Vilmann, Peter; Frost Clementsen, Paul; Colella, Sara

    2015-01-01

    This is an official guideline of the European Society of Gastrointestinal Endoscopy (ESGE), produced in cooperation with the European Respiratory Society (ERS) and the European Society of Thoracic Surgeons (ESTS). It addresses the benefit and burden associated with combined endobronchial and esop...

  9. AREVA's innovative solutions for valve diagnostics and in-situ valve repair

    International Nuclear Information System (INIS)

    Damies, H.; Breitenberger, U.; Munoz, L.; Kostroun, F.

    2012-01-01

    Optimized maintenance strategies are a key aspect for safe and undisturbed plant operation. Innovative valve service solutions can support that in an efficient way. The ADAM®/SIPLUG® valve monitoring system allows full online monitoring of valves and actuators with automatic evaluation and assessment. Especially for safety-related and operation-related valves this provides valuable information on components condition to ensure proper function and contribute to optimization of maintenance strategies as well as effective maintenance performance. More than 25 years of experience in various plants worldwide show that application of ADAM®/SIPLUG® valve diagnostics solution leads to increased plant safety and availability. With the innovative AVARIS technology an in-situ valve repair is possible. It has the unique ability to conduct several steps in-situ, to maintain the sealing seat of gate or check valves. By applying AVARIS, the valve is restored in its original state, the system remains unchanged. Thus, all original documents remain valid and applicable. In comparison to previous procedures like cutting valves out of the pipeline and repairing hard facings or damaged seal seats in a separate workshop or alternatively replacement by a new valve body the new AVARIS technology avoids costs, risk and effort. (author)

  10. Endobronchial intubation detected by insertion depth of endotracheal tube, bilateral auscultation, or observation of chest movements: randomised trial.

    Science.gov (United States)

    Sitzwohl, Christian; Langheinrich, Angelika; Schober, Andreas; Krafft, Peter; Sessler, Daniel I; Herkner, Harald; Gonano, Christopher; Weinstabl, Christian; Kettner, Stephan C

    2010-11-09

    To determine which bedside method of detecting inadvertent endobronchial intubation in adults has the highest sensitivity and specificity. Prospective randomised blinded study. Department of anaesthesia in tertiary academic hospital. 160 consecutive patients (American Society of Anesthesiologists category I or II) aged 19-75 scheduled for elective gynaecological or urological surgery. Patients were randomly assigned to eight study groups. In four groups, an endotracheal tube was fibreoptically positioned 2.5-4.0 cm above the carina, whereas in the other four groups the tube was positioned in the right mainstem bronchus. The four groups differed in the bedside test used to verify the position of the endotracheal tube. To determine whether the tube was properly positioned in the trachea, in each patient first year residents and experienced anaesthetists were randomly assigned to independently perform bilateral auscultation of the chest (auscultation); observation and palpation of symmetrical chest movements (observation); estimation of the position of the tube by the insertion depth (tube depth); or a combination of all three (all three). Correct and incorrect judgments of endotracheal tube position. 160 patients underwent 320 observations by experienced and inexperienced anaesthetists. First year residents missed endobronchial intubation by auscultation in 55% of cases and performed significantly worse than experienced anaesthetists with this bedside test (odds ratio 10.0, 95% confidence interval 1.4 to 434). With a sensitivity of 88% (95% confidence interval 75% to 100%) and 100%, respectively, tube depth and the three tests combined were significantly more sensitive for detecting endobronchial intubation than auscultation (65%, 49% to 81%) or observation(43%, 25% to 60%) (Pauscultation to detect inadvertent endobronchial intubation. But even experienced physicians will benefit from inserting tubes to 20-21 cm in women and 22-23 cm in men, especially when high

  11. Endobronchial cryotherapy facilitates end-stage treatment options in patients with bronchial stenosis: A case series

    Directory of Open Access Journals (Sweden)

    Gerard J Fitzmaurice

    2014-01-01

    Full Text Available In keeping with international trends, lung cancer incidence and mortality are increasing among the Irish population with many patients presenting with advanced disease that excludes the potential for curative management. Consequently palliative treatment options for this patient group are being increasingly explored with various degrees of success. Endobronchial stenosis represents a particularly challenging area of management among these patients and a number of techniques have been described without the identification of a single gold standard. We report our experience of the first time use of endobronchial cryotherapy in Ireland with reference to a case series, including an example of its use in the management of benign disease, in order to support patients with borderline lung function and enable definitive palliative treatment.

  12. Endobronchial cryotherapy facilitates end-stage treatment options in patients with bronchial stenosis: A case series.

    LENUS (Irish Health Repository)

    Fitzmaurice, Gerard J

    2014-04-01

    In keeping with international trends, lung cancer incidence and mortality are increasing among the Irish population with many patients presenting with advanced disease that excludes the potential for curative management. Consequently palliative treatment options for this patient group are being increasingly explored with various degrees of success. Endobronchial stenosis represents a particularly challenging area of management among these patients and a number of techniques have been described without the identification of a single gold standard. We report our experience of the first time use of endobronchial cryotherapy in Ireland with reference to a case series, including an example of its use in the management of benign disease, in order to support patients with borderline lung function and enable definitive palliative treatment.

  13. Diagnosis of invasive aspergillus tracheobronchitis facilitated by endobronchial ultrasound-guided transbronchial needle aspiration: a case report

    Directory of Open Access Journals (Sweden)

    Casal Roberto F

    2009-11-01

    Full Text Available Abstract Introduction Invasive pulmonary aspergillosis is the most common form of infection by Aspergillus species among immunocompromised patients. Although this infection frequently involves the lung parenchyma, it is unusual to find it limited to the tracheobronchial tree, a condition known as invasive aspergillus tracheobronchitis. Case presentation A 65 year-old Hispanic man from Bolivia with a history of chronic lymphocytic leukemia developed cough and malaise eight months after having an allogenic stem cell transplant. A computed tomography of the chest revealed an area of diffuse soft tissue thickening around the left main stem bronchus, which was intensely fluorodeoxyglucose-avid on positron emission tomography scanning. An initial bronchoscopic exam revealed circumferential narrowing of the entire left main stem bronchus with necrotic and friable material on the medial wall. Neither aspirates from this necrotic area nor bronchial washing were diagnostic. A second bronchoscopy with endobronchial ultrasound evidenced a soft tissue thickening on the medial aspect of the left main stem bronchus underlying the area of necrosis visible endoluminally. Endobronchial ultrasound-guided transbronchial needle aspiration performed in this area revealed multiple fungal elements suggestive of Aspergillus species. Conclusion We describe the first case of invasive aspergillus tracheobronchitis in which the diagnosis was facilitated by the use of endobronchial ultrasound guided trans-bronchial needle aspiration. To the best of our knowledge, we are also presenting the first positron emission tomography scan images of this condition in the literature. We cautiously suggest that endobronchial ultrasound imaging may be a useful tool to evaluate the degree of invasion and the involvement of vascular structures in these patients prior to bronchoscopic manipulation of the affected areas in an effort to avoid potentially fatal hemorrhage.

  14. Check valve

    Science.gov (United States)

    Upton, H.A.; Garcia, P.

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs.

  15. Check valve

    International Nuclear Information System (INIS)

    Upton, H.A.; Garcia, P.

    1999-01-01

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs

  16. Effectiveness of the Benign and Malignant Diagnosis of Mediastinal and Hilar Lymph Nodes by Endobronchial Ultrasound Elastography.

    Science.gov (United States)

    Huang, Haidong; Huang, Zhiang; Wang, Qin; Wang, Xinan; Dong, Yuchao; Zhang, Wei; Zarogoulidis, Paul; Man, Yan-Gao; Schmidt, Wolfgang Hohenforst; Bai, Chong

    2017-01-01

    Background and Objectives: Endobronchial ultrasound elastography is a new technique for describing the stiffness of tissue during endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). The aims of this study were to investigate the diagnostic value of Endobronchial ultrasound (EBUS) elastography for distinguishing the difference between benign and malignant lymph nodes among mediastinal and hilar lymph node. Materials and Methods: From June 2015 to August 2015, 47 patients confirmed of mediastinal and hilar lymph node enlargement through examination of Computed tomography (CT) were enrolled, and a total of 78 lymph nodes were evaluated by endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). EBUS-guided elastography of lymph nodes was performed prior to EBUS-TBNA. A convex probe EBUS was used with a new EBUS processor to assess elastographic patterns that were classified based on color distribution as follows: Type 1, predominantly non-blue (green, yellow and red); Type 2, part blue, part non-blue (green, yellow and red); Type 3, predominantly blue. Pathological determination of malignant or benign lymph nodes was used as the gold standard for this study. The elastographic patterns were compared with the final pathologic results from EBUS-TBNA. Results: On pathological evaluation of the lymph nodes, 45 were benign and 33 were malignant. The lymph nodes that were classified as Type 1 on endobronchial ultrasound elastography were benign in 26/27 (96.3%) and malignant in 1/27 (3.7%); for Type 2 lymph nodes, 15/20 (75.0%) were benign and 5/20 (25.0%) were malignant; Type 3 lymph nodes were benign in 4/31 (12.9%) and malignant in 27/31 (87.1%). In classifying Type 1 as 'benign' and Type 3 as 'malignant,' the sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy rates were 96.43%, 86.67%, 87.10%, 96.30%, 91.38%, respectively. Conclusion: EBUS elastography of mediastinal and

  17. Scissor thrust valve actuator

    Science.gov (United States)

    DeWall, Kevin G.; Watkins, John C; Nitzel, Michael E.

    2006-08-29

    Apparatus for actuating a valve includes a support frame and at least one valve driving linkage arm, one end of which is rotatably connected to a valve stem of the valve and the other end of which is rotatably connected to a screw block. A motor connected to the frame is operatively connected to a motor driven shaft which is in threaded screw driving relationship with the screw block. The motor rotates the motor driven shaft which drives translational movement of the screw block which drives rotatable movement of the valve driving linkage arm which drives translational movement of the valve stem. The valve actuator may further include a sensory control element disposed in operative relationship with the valve stem, the sensory control element being adapted to provide control over the position of the valve stem by at least sensing the travel and/or position of the valve stem.

  18. Multiple-port valve

    International Nuclear Information System (INIS)

    Doody, T.J.

    1978-01-01

    A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable with one or more of a plurality of secondary conduits fitting into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits

  19. A remote control valve

    International Nuclear Information System (INIS)

    Cachard, Maurice de; Dumont, Maurice.

    1976-01-01

    This invention concerns a remote control valve for shutting off or distributing a fluid flowing at a high rate and low pressure. Among the different valves at present in use, electric valves are the most recommended for remote control but their reliability is uncertain and they soon become costly when large diameter valves are used. The valve described in this invention does away with this drawback owing to its simplicity and the small number of moving parts, this makes it particularly reliable. It mainly includes: a tubular body fitted with at least one side opening; at least one valve wedge for this opening, coaxial with the body, and mobile; a mobile piston integral with this wedge. Several valves to the specifications of this invention can be fitted in series (a shut-off valve can be used in conjunction with one or more distribution valves). The fitting and maintenance of the valve is very simple owing to its design. It can be fabricated in any material such as metals, alloys, plastics and concrete. The structure of the valve prevents the flowing fluid from coming into contact with the outside environment, thereby making it particularly suitable in the handling of dangerous or corrosive fluids. Finally, the opening and shutting of the valve occurs slowly, thereby doing away with the water hammer effect so frequent in large bore pipes [fr

  20. Fermionic One-Way Quantum Computation

    International Nuclear Information System (INIS)

    Cao Xin; Shang Yun

    2014-01-01

    Fermions, as another major class of quantum particles, could be taken as carriers for quantum information processing beyond spins or bosons. In this work, we consider the fermionic generalization of the one-way quantum computation model and find that one-way quantum computation can also be simulated with fermions. In detail, using the n → 2n encoding scheme from a spin system to a fermion system, we introduce the fermionic cluster state, then the universal computing power with a fermionic cluster state is demonstrated explicitly. Furthermore, we show that the fermionic cluster state can be created only by measurements on at most four modes with |+〉 f (fermionic Bell state) being free

  1. Double-disc gate valve

    International Nuclear Information System (INIS)

    Wheatley, S.J.

    1979-01-01

    The invention relates to an improvement in a conventional double-disc gate valve having a vertically movable gate assembly including a wedge, spreaders slidably engaged therewith, a valve disc carried by the spreaders. When the gate assembly is lowered to a selected point in the valve casing, the valve discs are moved transversely outward to close inlet and outlet ports in the casing. The valve includes hold-down means for guiding the disc-and-spreader assemblies as they are moved transversely outward and inward. If such valves are operated at relatively high differential pressures, they sometimes jam during opening. Such jamming has been a problem for many years in gate valves used in gaseous diffusion plants for the separation of uranium isotopes. The invention is based on the finding that the above-mentioned jamming results when the outlet disc tilts about its horizontal axis in a certain way during opening of the valve. In accordance with the invention, tilting of the outlet disc is maintained at a tolerable value by providing the disc with a rigid downwardly extending member and by providing the casing with a stop for limiting inward arcuate movement of the member to a preselected value during opening of the valve

  2. Percutaneous bioprosthetic venous valve: a long-term study in sheep.

    Science.gov (United States)

    Pavcnik, Dusan; Uchida, Barry T; Timmermans, Hans A; Corless, Christopher L; O'Hara, Michael; Toyota, Naoyuki; Moneta, Gregory L; Keller, Frederick S; Rösch, Josef

    2002-03-01

    A long-term evaluation of a new percutaneously placed bioprosthetic, bicuspid venous valve (BVV) consisting of a square stent and small intestinal submucosa (SIS) covering was performed in 12 sheep. Of 26 BVVs placed into the jugular veins, 25 exhibited good valve function on immediate venography and 22 on venograms obtained before the sheep were killed. Gross and histologic examination results demonstrated incorporation of remodeled and endothelialized SIS BVVs into the vein wall. Slight to moderate leaflet thickening was found mostly at their bases. Percutaneously placed SIS BVV is a promising one-way, competent valve that resists venous back-pressure while allowing forward flow.

  3. How to learn and to perform endoscopic ultrasound and endobronchial ultrasound for lung cancer staging

    DEFF Research Database (Denmark)

    Konge, Lars; Colella, Sara; Vilmann, Peter

    2015-01-01

    The learning of transesophageal ultrasound guided fine needle aspiration (FNA) (endoscopic ultrasound-FNA), and endobronchial ultrasound guided transbronchial needle aspiration (endosonography) should be based on the following steps: Acquiring theoretical knowledge, training on simulators, and su...

  4. Endobronchial administration of iodine-131 B72.3 monoclonal antibody in patients with lung cancer

    International Nuclear Information System (INIS)

    Del Vecchio, S.; Mansi, L.; Petrillo, A.; Camera, L.; Salvatore, M.; Sofia, M.; Marra, A.; Carratu, L.

    1991-01-01

    We tested the feasibility of endobronchial administration of radiolabelled monoclonal antibodies (MoAbs) and the biodistribution of the radiotracer. Ten patients with histological confirmed adenocarcinoma or squamous cell carcinoma were studied. Nine received 470 μCi (103 μg) of 131 I-B72.3, a monoclonal antibody reacting against TAG 72 antigen, while one patient received 502 μCi (291 μg) of 131 I-4C4, an indifferent antibody used for comparison in a negative control study. The radiolabelled antibody was administered through a flexible fiberoptic bronchoscope and placed on the tumour mass under visual monitoring. Scans with a large field-of-view gamma-camera showed retention of 131 I-B72.3 at the tumour site up to 6-9 days in six of eight patients. No other organs were visualized with the exception of faint activity in the gastrointestinal tract, bladder and thyroid. On the contrary, the indifferent antibody 131 I-4C4 was not retained at the tumour site 6 days after MoAbs administration, and more prominent activity was found in the gastrointestinal tract. In one patient the study was not technically adequate because of failure of the delivery system. The vascular compartment contained less than 3% of the administered dose. We conclude that endobronchial administration is a feasible technique and allows stable and specific targetting of bronchial tumours. Furthermore, the low activity found in the plasma and other organs suggests that this approach may be used to deliver therapeutic doses of MoAbs to lung cancers. (orig.)

  5. Mitral Valve Prolapse

    Science.gov (United States)

    Mitral valve prolapse (MVP) occurs when one of your heart's valves doesn't work properly. The flaps of the valve are "floppy" and ... to run in families. Most of the time, MVP doesn't cause any problems. Rarely, blood can ...

  6. Use of a valve operation test and evaluation system to enhance valve reliability

    International Nuclear Information System (INIS)

    Lowry, D.A.

    1990-01-01

    Power plant owners have emphasized the need for assuring safe, reliable operation of valves. While most valves must simply open or close, the mechanisms involved can be quite complex. Motor operated valves (MOVs) must be properly adjusted to assure operability. Individual operator components determine the performance of the entire MOV. Failure in MOVs could cripple or shut down a unit. Thus, a complete valve program consisting of design reviews, operational testing, and preventive and predictive maintenance activities will enhance an owner's confidence level that his valves win operate as expected. Liberty's Valve Operation Test and Evaluation System (VOTES) accurately measures stein thrust without intruding on valve operation. Since mounting a strain gage to a valve stem is a desirable but impractical way of obtaining precise stem thrust, Liberty developed a method to obtain identical data by placing a strain gage sensor on the valve yoke. VOTES provides information which effectively eliminates costly, unscheduled downtime. This paper presents the results of infield VOTES testing. The system's proven ability to identify and characterize actuator and valve performance is demonstrated. Specific topics of discussion include the ability of VOTES to ease a utility's IE Bulletin 8543 concerns and conclusively diagnose MOV components. Data from static and differential pressure testing are presented. Technical, operational, and financial advantages resulting from VOTES technology are explored in detail

  7. Swing check valve

    International Nuclear Information System (INIS)

    Eminger, H.E.

    1977-01-01

    A swing check valve which includes a valve body having an inlet and outlet is described. A recess in the valve body designed to hold a seal ring and a check valve disc swingable between open and closed positions. The disc is supported by a high strength wire secured at one end in a support spacer pinned through bearing blocks fixed to the valve body and at its other end in a groove formed on the outer peripheral surface of the disc. The parts are designed and chosen such to provide a lightweight valve disc which is held open by minimum velocity of fluid flowing through the valve which thus reduces oscillations and accompanying wear of bearings supporting the valve operating parts. (Auth.)

  8. Heart Valve Diseases

    Science.gov (United States)

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  9. The safety valve and climate policy

    International Nuclear Information System (INIS)

    Jacoby, Henry D.; Ellerman, A.D.

    2004-01-01

    The 'safety valve' is a possible addition to a cap-and-trade system of emissions regulation whereby the authority offers to sell permits in unlimited amount at a pre-set price. In this way the cost of meeting the cap can be limited. It was proposed in the US as a way to control perceived high costs of the Kyoto Protocol, and possibly as a way to shift the focus of policy from the quantity targets of the Protocol to emissions price. In international discussions, the idea emerged as a proposal for a compliance penalty. The usefulness of the safety valve depends on the conditions under which it might be introduced. For a time it might tame an overly stringent emissions target. It also can help control the price volatility during the introduction of gradually tightening one, although permit banking can ultimately serve the same function. It is unlikely to serve as a long-term feature of a cap-and-trade system, however, because of the complexity of coordinating price and quantity instruments and because it will interfere with the development of systems of international emissions trade

  10. Design of pneumatic proportional flow valve type 5/3

    Science.gov (United States)

    Laski, P. A.; Pietrala, D. S.; Zwierzchowski, J.; Czarnogorski, K.

    2017-08-01

    In this paper the 5/3-way pneumatic, proportional flow valve was designed and made. Stepper linear actuator was used to move the spool. The valve is controlled by the controlled based on a AVR microcontroller. Virtual model of the valve was created in CAD. The real element was made based on a standard 5/3-way manually actuated valve with hand lever, which was dismounted and replaced by linear stepper motor. All the elements was mounted in a specially made housing. The controller consists of microcontroller Atmega16, integrated circuit L293D, display, two potentiometers, three LEDs and six buttons. Series of research was also conducted. Simulation research were performed using CFD by the Flow Simulation addition to SolidWorks. During the experiments the valve characteristics of flow and pressure was determined.

  11. Intro to Valve Guide Reconditioning. Automotive Mechanics. Valves. Instructor's Guide [and] Student Guide.

    Science.gov (United States)

    Horner, W.

    This instructional package, one in a series of individualized instructional units on tools and techniques for repairing worn valve guides in motor vehicles, provides practical experience for students in working on cylinder heads. Covered in the module are reaming valve guides that are oversized to match a new oversized valve, reaming valve guides…

  12. Endobronchial Forceps-Assisted and Excimer Laser-Assisted Inferior Vena Cava Filter Removal: The Data, Where We Are, and How It Is Done.

    Science.gov (United States)

    Chen, James X; Montgomery, Jennifer; McLennan, Gordon; Stavropoulos, S William

    2018-06-01

    The recognition of inferior vena cava filter related complications has motivated increased attentiveness in clinical follow-up of patients with inferior vena cava filters and has led to development of multiple approaches for retrieving filters that are challenging or impossible to remove using conventional techniques. Endobronchial forceps and excimer lasers are tools for designed to aid in complex inferior vena cava filter removals. This article discusses endobronchial forceps-assisted and excimer laser-assisted inferior vena cava filter retrievals. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation.

    Science.gov (United States)

    Allen, Keith B; Chhatriwalla, Adnan K; Cohen, David J; Saxon, John T; Aggarwal, Sanjeev; Hart, Anthony; Baron, Suzanne; Davis, J Russell; Pak, Alex F; Dvir, Danny; Borkon, A Michael

    2017-11-01

    Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Linfoma não-Hodgkin endobrônquico Endobronchial involvement in non-Hodgkin’s lymphoma

    Directory of Open Access Journals (Sweden)

    Mauro Zamboni

    2004-02-01

    Full Text Available Os linfomas não-Hodgkin fazem parte de um grupo de doenças malignas linfoproliferativas com diferentes padrões de comportamento, de tratamento e de prognóstico. Eles podem comprometer as estruturas intratorácicas, particularmente o mediastino e o parênquima pulmonar, em alguma fase do curso da doença. Entretanto, o envolvimento endobrônquico é extremamente raro, mesmo na presença de doença avançada. Os autores relatam um caso de linfoma não-Hodgkin endobrônquico e fazem revisão da literatura.Non-Hodgkin’s lymphomas belong to a group of lymphoproliferative malignancies with different behavior, treatment and prognostic patterns. During the course of the disease, they may affect the thoracic structures - especially the mediastinum and the pulmonary parenchyma. However endobronchial involvement is extremely uncommon, even in presence of advanced disease. Here, we report a case of non-Hodgkin’s endobronchial lymphoma and make a review of the literature.

  15. Endobronchial and endoesophageal high dose rate brachytherapy for malignant airway and digestive tract obstructions

    International Nuclear Information System (INIS)

    Mehta, Minesh P.

    1996-01-01

    With an annual incidence of more than 160,000 cases and a local failure rate between 30-50%, endobronchial occlusion seen with lung cancer is a common and potentially life-threatening complication. Several methods of managing this exist and recently endobronchial brachytherapy has been used extensively as a consequence of the development of fiberoptic bronchoscopy and high dose rate remote afterloading technology. Procedurally, one or more afterloading catheters are inserted in the involved portions of the tracheobronchial tree through fiberoptic guidance. Treatment techniques range from 1-4 applications fractionated over several weeks or given over 2 days with a single insertion procedure. Almost all procedures are currently performed in the outpatient setting. The major application of this technology is in the palliation of occlusive symptomatology. Clinical improvement ranges from 50-100%, radiographic reaeration ranges from 46-88% and bronchoscopic responses ranges from 59-100%. Symptomatic relief is usually quite durable with more than 70% of the patients' remaining life-time rendered symptom-free and symptom-improved. Recently, this modality has been explored for its curative potential as a boost following external beam radiotherapy. It is clear from these series, that in selected patients, endobronchial boost produces significant reaeration and sparing of lung volume from subsequent external radiation, and a few cases may even become resectable. Demonstration of the survival advantage will, however, require larger clinical trials with adequate controls. Some reports have suggested an unacceptably high rate of fatal hemoptysis following HDR endobronchial brachytherapy. Review of the world literature suggests that fatal hemoptysis rates range from 0-50% with an average of about 8%, comparable to an average of 5% with low dose rate brachytherapy. Other recognized complications include fistulae and radiation bronchitis. Because the majority of patients with

  16. Comparative analysis of the performance of One-Way and Two-Way urban road networks

    Science.gov (United States)

    Gheorghe, Carmen

    2017-10-01

    The fact that the number of vehicles is increasing year after year represents a challenge in road traffic management because it is necessary to adjust the road traffic, in order to prevent any incidents, using mostly the same road infrastructure. At this moment one-way road network provides efficient traffic flow for vehicles but it is not ideal for pedestrians. Therefore, a proper solution must be found and applied when and where it is necessary. Replacing one-way road network with two-way road network may be a viable solution especially if in the area is high pedestrian traffic. The paper aims to highlight the influence of both, one-way and two-way urban road networks through an experimental research which was performed by using traffic data collected in the field. Each of the two scenarios analyzed were based on the same traffic data, the same geometrical conditions of the road (lane width, total road segment width, road slopes, total length of the road network) and also the same signaling conditions (signalised intersection or roundabout). The analysis which involves two-way scenario reveals changes in the performance parameters like delay average, stops average, delay stop average and vehicle speed average. Based on the values obtained, it was possible to perform a comparative analysis between the real, one-way, scenario and the theoretical, two-way, scenario.

  17. Transcatheter aortic valve-in-valve treatment of degenerative stentless supra-annular Freedom Solo valves: A single centre experience.

    Science.gov (United States)

    Cockburn, James; Dooley, Maureen; Parker, Jessica; Hill, Andrew; Hutchinson, Nevil; de Belder, Adam; Trivedi, Uday; Hildick-Smith, David

    2017-02-15

    Redo surgery for degenerative bioprosthetic aortic valves is associated with significant morbidity and mortality. Report results of valve-in-valve therapy (ViV-TAVI) in failed supra-annular stentless Freedom Solo (FS) bioprostheses, which are the highest risk for coronary occlusion. Six patients with FS valves (mean age 78.5 years, 50% males). Five had valvular restenosis (peak gradient 87.2 mm Hg, valve area 0.63 cm 2 ), one had severe regurgitation (AR). Median time to failure was 7 years. Patients were high risk (mean STS/Logistic EuroScore 10.6 15.8, respectively). FS valves ranged from 21 to 25 mm. Successful ViV-TAVI was achieved in 4/6 patients (67%). Of the unsuccessful cases, (patient 1 and 2 of series) patient 1 underwent BAV with simultaneous aortography which revealed left main stem occlusion. The procedure was stopped and the patient went forward for repeat surgery. Patient 2 underwent successful ViV-TAVI with a 26-mm CoreValve with a guide catheter in the left main, but on removal coronary obstruction occurred, necessitating valve snaring into the aorta. Among the successful cases, (patients 3, 4, 5, 6) the TAVIs used were CoreValve Evolut R 23 mm (n = 3), and Lotus 23 mm (n = 1). In the successful cases the peak gradient fell from 83.0 to 38.3 mm Hg. No patient was left with >1+ AR. One patient had a stroke on Day 2, with full neurological recovery. Two patients underwent semi-elective pacing for LBBB and PR >280 ms. ViV-TAVI in stentless Freedom Solo valves is high risk. The risk of coronary occlusion is high. The smallest possible prosthesis (1:1 sizing) should be used, and strategies to protect the coronary vessels must be considered. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  18. [Endobronchial Ultrasound (EBUS) - an Update 2017].

    Science.gov (United States)

    Darwiche, K; Özkan, F; Wolters, C; Eisenmann, S

    2017-11-01

    Endobronchial Ultrasound (EBUS) with the two modalities curved and radial EBUS significantly improved the diagnostics in several pulmonary diseases. The examination and staging of mediastinal and hilar lymph nodes in patients with known or suspected lung malignancy as well as the evaluation of unknown pulmonary or mediastinal lesions can be achieved with minimal invasive means when using EBUS. More invasive surgical procedures for diagnostic purposes can be omitted. The diagnostic yield also increases when EBUS is applied in sarcoidosis or mediastinal lymph node tuberculosis but only to some extend in case of lymphoma. Samples obtained by EBUS-TBNA should be handled efficiently to allow molecular analysis in lung cancer. EBUS is a safe procedure, and complication rate is extremely low. Further advances of the EBUS technology focus on improving analysis of the information provided by the ultrasound image and a better tissue sampling by developing of new EBUS bronchoscopes and TBNA-needles. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Trans-apical aortic valve implantation in a patient with stentless valve degeneration.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; MacCarthy, Philip; Monaghan, Mark; Wendler, Olaf

    2011-06-01

    Trans-apical valve-in-valve trans-catheter aortic valve implantation (TAVI) has successfully been performed in selected, high-risk patients, who suffered prosthetic degeneration after aortic valve replacement using stented xenografts. We report the case of a 79-year-old male patient who underwent one of the first successful TAVIs in a failing stentless bioprosthesis. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  20. Deterministic one-way simulation of two-way, real-time cellular automata and its related problems

    Energy Technology Data Exchange (ETDEWEB)

    Umeo, H; Morita, K; Sugata, K

    1982-06-13

    The authors show that for any deterministic two-way, real-time cellular automaton, m, there exists a deterministic one-way cellular automation which can simulate m in twice real-time. Moreover the authors present a new type of deterministic one-way cellular automata, called circular cellular automata, which are computationally equivalent to deterministic two-way cellular automata. 7 references.

  1. Impact of endobronchial coiling on segmental bronchial lumen in treated and untreated lung lobes: Correlation with changes in lung volume, clinical and pulmonary function tests.

    Science.gov (United States)

    Kloth, C; Thaiss, W M; Hetzel, J; Ditt, H; Grosse, U; Nikolaou, K; Horger, M

    2016-07-01

    To assess the impact of endobronchial coiling on the segment bronchus cross-sectional area and volumes in patients with lung emphysema using quantitative chest-CT measurements. Thirty patients (female = 15; median age = 65.36 years) received chest-CT before and after endobronchial coiling for lung volume reduction (LVR) between January 2010 and December 2014. Thin-slice (0.6 mm) non-enhanced image data sets were acquired both at end-inspiration and end-expiration using helical technique and 120 kV/100-150 mAs. Clinical response was defined as an increase in the walking distance (Six-minute walk test; 6MWT) after LVR-therapy. Additionally, pulmonary function test (PFT) measurements were used for clinical correlation. In the treated segmental bronchia, the cross-sectional lumen area showed significant reduction (p  0.05). In the ipsilateral lobes, the lumina showed no significant changes. In the contralateral lung, we found tendency towards increased cross-sectional area in inspiration (p = 0.06). Volumes of the treated segments correlated with the treated segmental bronchial lumina in expiration (r = 0.80, p volume of the treated lobe in responders only. Endobronchial coiling causes significant decrease in the cross-sectional area of treated segment bronchi in inspiration and a slight increase in expiration accompanied by a volume reduction. • Endobronchial coiling has indirect impact on cross-sectional area of treated segment bronchi • Volume changes of treated lobes correlate with changes in bronchial cross-sectional area • Coil-induced effects reflect their stabilizing and stiffening impact on lung parenchyma • Endobronchial coiling reduces bronchial collapsing compensating the loss of elasticity.

  2. Force measuring valve assemblies, systems including such valve assemblies and related methods

    Science.gov (United States)

    DeWall, Kevin George [Pocatello, ID; Garcia, Humberto Enrique [Idaho Falls, ID; McKellar, Michael George [Idaho Falls, ID

    2012-04-17

    Methods of evaluating a fluid condition may include stroking a valve member and measuring a force acting on the valve member during the stroke. Methods of evaluating a fluid condition may include measuring a force acting on a valve member in the presence of fluid flow over a period of time and evaluating at least one of the frequency of changes in the measured force over the period of time and the magnitude of the changes in the measured force over the period of time to identify the presence of an anomaly in a fluid flow and, optionally, its estimated location. Methods of evaluating a valve condition may include directing a fluid flow through a valve while stroking a valve member, measuring a force acting on the valve member during the stroke, and comparing the measured force to a reference force. Valve assemblies and related systems are also disclosed.

  3. Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis.

    Science.gov (United States)

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel; Brito, João; Sondergaard, Lars; Neves, José P; Abecasis, João; M Gabriel, Henrique

    2017-03-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected for surgery due to advanced age and comorbidities. The patient underwent a first TAVI, with implantation of a Medtronic CoreValve ® , which became dislodged and migrated to the ascending aorta. Due to the previous balloon valvuloplasty, the patient's AS became moderate, and her symptoms improved. After several months, she required another intervention, performed with a St. Jude Portico ® repositionable self-expanding transcatheter aortic valve. There was a good clinical response that was maintained at one-year follow-up. The use of a self-expanding transcatheter bioprosthesis with repositioning features is a solution in cases of valve dislocation to avoid suboptimal positioning of a second implant, especially when the two valves have to be positioned overlapping or partially overlapping each other. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Moments Based Framework for Performance Analysis of One-Way/Two-Way CSI-Assisted AF Relaying

    KAUST Repository

    Xia, Minghua

    2012-09-01

    When analyzing system performance of conventional one-way relaying or advanced two-way relaying, these two techniques are always dealt with separately and, thus, their performance cannot be compared efficiently. Moreover, for ease of mathematical tractability, channels considered in such studies are generally assumed to be subject to Rayleigh fading or to be Nakagami-$m$ channels with integer fading parameters, which is impractical in typical urban environments. In this paper, we propose a unified moments-based framework for general performance analysis of channel-state-information (CSI) assisted amplify-and-forward (AF) relaying systems. The framework is applicable to both one-way and two-way relaying over arbitrary Nakagami-$m$ fading channels, and it includes previously reported results as special cases. Specifically, the mathematical framework is firstly developed under the umbrella of the weighted harmonic mean of two Gamma-distributed variables in conjunction with the theory of Pad\\\\\\'e approximants. Then, general expressions for the received signal-to-noise ratios of the users in one-way/two-way relaying systems and the corresponding moments, moment generation function, and cumulative density function are established. Subsequently, the mathematical framework is applied to analyze, compare, and gain insights into system performance of one-way and two-way relaying techniques, in terms of outage probability, average symbol error probability, and achievable data rate. All analytical results are corroborated by simulation results as well as previously reported results whenever available, and they are shown to be efficient tools to evaluate and compare system performance of one-way and two-way relaying.

  5. Valve for closing a steam line

    International Nuclear Information System (INIS)

    Meyer, W.; Potrykus, G.

    1976-01-01

    Instead of several control elements, the quick-closing valve, especially in the main-steam line between steam generator and turbine of a power station has the valve cone itself as the only movable part, acting with its inner surface as a piston within a second cylinder space. The valve shaft is at the same time a piston rod with a stepped piston at the upper end. This piston is loaded in a cylinder at the upspace below the valve cover on one hand by a spring, on the other hand by its own medium. Two non-return valves, one of it in a bore of the valve cone, connect the first-mentioned cylinder space with the steam-loaded inlet resp. outlet side of the valve. For controlling the valve, a magnet valve is sufficient. By automatic control of the valve cone coupled with several pistons several control lines can be omitted. There are also no pressurized control lines outside the valve which could be damaged by exterior influences. (ERA) [de

  6. Early and mid-term results of autograft rescue by Ross reversal: A one-valve disease need not become a two-valve disease.

    Science.gov (United States)

    Hussain, Syed T; Majdalany, David S; Dunn, Aaron; Stewart, Robert D; Najm, Hani K; Svensson, Lars G; Houghtaling, Penny L; Blackstone, Eugene H; Pettersson, Gösta B

    2018-02-01

    Risk of reoperation and loss of a second native valve are major drawbacks of the Ross operation. Rather than discarding the failed autograft, it can be placed back into the native pulmonary position by "Ross reversal." We review our early and mid-term results with this operation. From 2006 to 2017, 39 patients underwent reoperation for autograft dysfunction. The autograft was successfully rescued in 35 patients: by Ross reversal in 30, David procedure in 4, and autograft repair in 1. Medical records were reviewed for patient characteristics (mean age was 46 ± 13 years, range 18-67 years, and 23 were male), previous operations, indications for reoperation, hospital outcomes, and echocardiographic findings for the 30 patients undergoing successful Ross reversal. Follow-up was 4.1 ± 3.5 years (range 7 months-11 years). Median interval between the original Ross procedure and Ross reversal was 12 years (range 5-19 years). Eight patients also had absolute indications for replacement of the pulmonary allograft. There was no operative mortality. One patient required reoperation for bleeding. Another had an abdominal aorta injury from use of an endoballoon clamp. There was no other major postoperative morbidity, and median postoperative hospital stay was 7.2 days (range 4-41 days). No patient required reoperation during follow-up. Twenty-four patients had acceptable pulmonary valve function, and 6 had clinically well-tolerated moderate or severe pulmonary regurgitation. Ross reversal can be performed with low morbidity and acceptable pulmonary valve function, reducing patient risk of losing 2 native valves when the autograft fails in the aortic position. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  7. Efficient quantum circuits for one-way quantum computing.

    Science.gov (United States)

    Tanamoto, Tetsufumi; Liu, Yu-Xi; Hu, Xuedong; Nori, Franco

    2009-03-13

    While Ising-type interactions are ideal for implementing controlled phase flip gates in one-way quantum computing, natural interactions between solid-state qubits are most often described by either the XY or the Heisenberg models. We show an efficient way of generating cluster states directly using either the imaginary SWAP (iSWAP) gate for the XY model, or the sqrt[SWAP] gate for the Heisenberg model. Our approach thus makes one-way quantum computing more feasible for solid-state devices.

  8. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve

    DEFF Research Database (Denmark)

    Aagaard, Jan; Geha, Alexander S.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The CarboMedics Top Hat supra-annular aortic valve allows a one-size (and often two-size) increase over the standard intra-annular valve. This advantage should minimize the risk of patient-prosthesis mismatch, where the effective prosthetic valve orifice area....... This study evaluates the authors' clinical experience with Top Hat supra-annular aortic valve size selection, and the technical aspects of implantation. METHODS: Between January 1999 and October 2005, a total of 251 consecutive patients underwent 252 aortic valve replacements with Top Hat supra...... required unplanned coronary bypass, and 30-day mortality was 2.0% (5/251), indicating a good safety profile for the valves implanted in this series. CONCLUSION: The general distribution of implant sizes in the US indicates that cardiac surgeons may be under-sizing the Top Hat supra-annular aortic valve...

  9. FVCOM one-way and two-way nesting using ESMF: Development and validation

    Science.gov (United States)

    Qi, Jianhua; Chen, Changsheng; Beardsley, Robert C.

    2018-04-01

    Built on the Earth System Modeling Framework (ESMF), the one-way and two-way nesting methods were implemented into the unstructured-grid Finite-Volume Community Ocean Model (FVCOM). These methods help utilize the unstructured-grid multi-domain nesting of FVCOM with an aim at resolving the multi-scale physical and ecosystem processes. A detail of procedures on implementing FVCOM into ESMF was described. The experiments were made to validate and evaluate the performance of the nested-grid FVCOM system. The first was made for a wave-current interaction case with a two-domain nesting with an emphasis on qualifying a critical need of nesting to resolve a high-resolution feature near the coast and harbor with little loss in computational efficiency. The second was conducted for the pseudo river plume cases to examine the differences in the model-simulated salinity between one-way and two-way nesting approaches and evaluate the performance of mass conservative two-way nesting method. The third was carried out for the river plume case in the realistic geometric domain in Mass Bay, supporting the importance for having the two-way nesting for coastal-estuarine integrated modeling. The nesting method described in this paper has been used in the Northeast Coastal Ocean Forecast System (NECOFS)-a global-regional-coastal nesting FVCOM system that has been placed into the end-to-end forecast and hindcast operations since 2007.

  10. Nuclear reactor steam depressurization valve

    International Nuclear Information System (INIS)

    Moore, G.L.

    1991-01-01

    This patent describes improvement in a nuclear reactor plant, an improved steam depressurization valve positioned intermediate along a steam discharge pipe for controlling the venting of steam pressure from the reactor through the pipe. The improvement comprises: a housing including a domed cover forming a chamber and having a partition plate dividing the chamber into a fluid pressure activation compartment and a steam flow control compartment, the valve housing being provided with an inlet connection and an outlet connection in the steam flow control compartment, and a fluid duct in communication with a source of fluid pressure for operating the valve; a valve set mounted within the fluid flow control compartment comprising a cylindrical section surrounding the inlet connection with one end adjoining the connection and having a radially projecting flange at the other end with a contoured extended valve sealing flange provided with an annular valve sealing member, and a valve cylinder traversing the partition plate and reciprocally movable within an opening in the partition plate with one terminal and extending into the fluid pressure activation compartment and the other terminal end extending into the steam flow control compartment coaxially aligned with the valve seat surrounding the inlet connection, the valve cylinder being surrounded by two bellow fluid seals and provided with guides to inhibit lateral movement, an end of the valve cylinder extending into the fluid flow control compartment having a radially projecting flange substantially conterminous with the valve seat flange and having a contoured surface facing and complimentary to the contoured valve seating surface whereby the two contoured valve surfaces can meet in matching relationship, thus providing a pressure actuated reciprocatable valve member for making closing contact with the valve seat and withdrawing therefrom for opening fluid flow through the valve

  11. Treatment of 9 cases of pulmonary atelectasis caused by endobronchial tuberculosis with intraluminal stent implantation

    International Nuclear Information System (INIS)

    Ji Hongjiang; Li Qiang; Liu Zhongling; Bai Chong; Yao Xiaopeng; Zhao Lijun; Xu Hao; Dong Yuchao; Huang Haidong; Wang Qin

    2007-01-01

    Objective: To evaluate the effect and safety of intraluminal stent implantation in the treatment of complete airway obstruction with unilateral pulmonary atelectasis caused by endobronchial tuberculosis (EBTB). Methods: 9 cases of pulmonary atelectasis caused by EBTB were treated with high- frequency electricity/microwave, balloon dilation and endobronchial stent implantation. At the time of 1 week and 4-6 months after stenting ,the diameters of stenotic segment were measured. Results: All 9 cases with atelectasis of EBTB showed complete re-expansion within 3 days after the stent implantation. The mean diameter of the stenotic segments of 9 EBTB patients increased to 9.17 ± 1.24 mm at 7th day after stent implantation; 3 of 9 EBTB patients occured mild restenosis after implantation of tracheobronchial stents. However, combination therapy of cryotherapy and balloon dilation can effectively prevent the aggravation of restenosis. Conclusion: Comparing with traditional surgical treatment, the intraluminal stent implantation for atelectasis caused by EBTB is a new, effective, safe and microtraumatic method with reliable preservation of pulmonary function. (authors)

  12. Efficiency of use endobronchial laser doppler-flowmetry in patients with chronic leukemia

    Science.gov (United States)

    Vanina, E. A.; Voitsekhovskiy, V. V.; Landyshev, Y. S.; Tkacheva, S. I.

    2016-11-01

    In this work indicatorsendobronchial microcirculation were investigated in patients with chronic myeloid leukemia (CML), chronic lymphocytic leukemia (CLL), multiple myeloma (MM), polycythemia vera (PV), idiopathic myelofibrosis (IMF). A diagnostic bronchoscopy was performed using fibreoptic «Olympus» (Japan).Endobronchial laser Doppler flowmetry was carried out on the laser analyzer capillary blood LAK-02 (Russia). Laser Doppler flowmetry indicators such as parameter of microcirculation, the oscillation amplitude in the endothelial, neurogenic, myogenic, cardiac and respiratory ranges were calculated by continuous the Wavelet transforms. Reduced cardiac and respiratory amplitudes in CML and CLL are primarily due to the development leukostasis. If PV is the case, this is due to sludge syndrome. And when MM occurs, it is caused by protein stasis in the vessels of the bronchial tubes. Increased endothelial oscillation amplitudes in the range in CML, PV, IMF and their reduction in MM indicate the presence of endothelial dysfunction in these patients. Increasing the amplitude of oscillations in the range of neurogenic indicates the development of arteriolar vasodilation as a compensatory response to the violation of blood flow. Increasing the amplitude of oscillations of myogenic tone indicating decrease precapillaries as a compensatory reaction to improve blood flow. It is concluded that endobronchial laser Doppler flowmetry is an important method allowing diagnosing the pathology of the microvasculature of the bronchi in chronic leukemia.

  13. Churg–Strauss Syndrome Presenting with Endobronchial Masses

    Directory of Open Access Journals (Sweden)

    Veli Çetinsu

    2015-12-01

    Full Text Available Churg–Strauss syndrome is a condition with unknown etiology and asthma, allergic rhinitis, eosinophilic infiltration of blood and tissues, and transient infiltration of the lungs. It occurs mostly in the 3rd–4th decades of life with an incidence of 2.4/1000000. Presentation frequently involves nodular lung infiltrations, infiltrations with cavity, ground-glass appearance, and alveolar opacity. However, endobronchial mass is an unexpected presentation. In the current case report, we present a 45-year-old male patient who was receiving asthma therapy for 5 years. In the last follow-up visit, we identified a mass in the right hilum on X-ray radiography and performed fiberoptic bronchoscopy. Pathologic examination of biopsy material verified the diagnosis of Churg–Strauss syndrome. Bronchial mass is an unexpected presentation of Churg–Strauss syndrome and pathologic examination is essential to distinguish it from pulmonary malignancies

  14. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  15. One-way shared memory

    DEFF Research Database (Denmark)

    Schoeberl, Martin

    2018-01-01

    Standard multicore processors use the shared main memory via the on-chip caches for communication between cores. However, this form of communication has two limitations: (1) it is hardly time-predictable and therefore not a good solution for real-time systems and (2) this single shared memory...... is a bottleneck in the system. This paper presents a communication architecture for time-predictable multicore systems where core-local memories are distributed on the chip. A network-on-chip constantly copies data from a sender core-local memory to a receiver core-local memory. As this copying is performed...... in one direction we call this architecture a one-way shared memory. With the use of time-division multiplexing for the memory accesses and the network-on-chip routers we achieve a time-predictable solution where the communication latency and bandwidth can be bounded. An example architecture for a 3...

  16. Analysis of flow instability in steam turbine control valves

    International Nuclear Information System (INIS)

    Pluviose, M.

    1981-01-01

    With the sponsorship of Electricite de France and the French steam turbine manufacturers, the Gas Turbine Laboratory of CETIM has started a research about the unsteady phenomena of flow in control valves of steam turbines. The existence of unsteady embossment in the valve cone at rise has been as certained, and a conventional computing procedure has been applied to locate the shock waves in the valve. These shock waves may suddenly arise at some valve lifts and give way to fluttering. Valve geometries attenuating instability of flow and increasing therefore the reliability of such equipment are proposed [fr

  17. One-way mode transmission in one-dimensional phononic crystal plates

    Science.gov (United States)

    Zhu, Xuefeng; Zou, Xinye; Liang, Bin; Cheng, Jianchun

    2010-12-01

    We investigate theoretically the band structures of one-dimensional phononic crystal (PC) plates with both antisymmetric and symmetric structures, and show how unidirectional transmission behavior can be obtained for either antisymmetric waves (A modes) or symmetric waves (S modes) by exploiting mode conversion and selection in the linear plate systems. The theoretical approach is illustrated for one PC plate example where unidirectional transmission behavior is obtained in certain frequency bands. Employing harmonic frequency analysis, we numerically demonstrate the one-way mode transmission for the PC plate with finite superlattice by calculating the steady-state displacement fields under A modes source (or S modes source) in forward and backward direction, respectively. The results show that the incident waves from A modes source (or S modes source) are transformed into S modes waves (or A modes waves) after passing through the superlattice in the forward direction and the Lamb wave rejections in the backward direction are striking with a power extinction ratio of more than 1000. The present structure can be easily extended to two-dimensional PC plate and efficiently encourage practical studies of experimental realization which is believed to have much significance for one-way Lamb wave mode transmission.

  18. One-way entangled-photon autocompensating quantum cryptography

    Science.gov (United States)

    Walton, Zachary D.; Abouraddy, Ayman F.; Sergienko, Alexander V.; Saleh, Bahaa E.; Teich, Malvin C.

    2003-06-01

    A quantum cryptography implementation is presented that uses entanglement to combine one-way operation with an autocompensating feature that has hitherto only been available in implementations that require the signal to make a round trip between the users. Using the concept of advanced waves, it is shown that this proposed implementation is related to the round-trip implementation in the same way that Ekert’s two-particle scheme is related to the original one-particle scheme of Bennett and Brassard. The practical advantages and disadvantages of the proposed implementation are discussed in the context of existing schemes.

  19. One-way entangled-photon autocompensating quantum cryptography

    International Nuclear Information System (INIS)

    Walton, Zachary D.; Abouraddy, Ayman F.; Sergienko, Alexander V.; Saleh, Bahaa E. A.; Teich, Malvin C.

    2003-01-01

    A quantum cryptography implementation is presented that uses entanglement to combine one-way operation with an autocompensating feature that has hitherto only been available in implementations that require the signal to make a round trip between the users. Using the concept of advanced waves, it is shown that this proposed implementation is related to the round-trip implementation in the same way that Ekert's two-particle scheme is related to the original one-particle scheme of Bennett and Brassard. The practical advantages and disadvantages of the proposed implementation are discussed in the context of existing schemes

  20. Experimental all-optical one-way quantum computing

    International Nuclear Information System (INIS)

    Prevedel, R.

    2009-01-01

    In recent years, the relatively new field of quantum information processing (QIP) has attracted the attention of many scientists around the world due to its promise of increased computational speed, absolute secure communication and the potential to simulate complex quantum mechanical systems. The very essence of this new quantum information technology are two concepts at the very heart of quantum mechanics, namely superposition and entanglement. The present Thesis contains the results of four different experiments that were all aimed at the demonstration of an entirely new model for quantum computing with linear optics, the 'one-way' quantum computer. For this purpose a multi-photon entangled state of four photons has been generated via the process of spontaneous parametric down-conversion and by using an interferometric setup. This entangled state acts as a resource that allowed for novel demonstrations of quantum algorithms and relevant experimental techniques. By exploiting the advances developed in both theory and experiment, in this Thesis we report the implementation of fast, active feed-forward that allowed, for the first time, the realization of deterministic linear optics quantum computing at an unprecedented speed. Further we were able to demonstrate the Deutsch algorithm on our one-way quantum computer, an important quantum algorithm that is capable of distinguishing whether a function is constant or balanced. Classically one needs to query the algorithm at least 2N/2 + 1 times for an N-bit binary input string, however, in the quantum regime, this can be done with one evaluation of the algorithm, independent of the size of the input. In another experiment we succeeded in playing an instance of a quantum game - the so-called Prisoner's dilemma - on our one-way quantum computer. Playing such a game is essentially the execution of a quantum algorithm made up of a distinct set of one- and two-qubit gates. This allows the individual players to increase their

  1. Flowfield Analysis of a Pneumatic Solenoid Valve

    Directory of Open Access Journals (Sweden)

    Sheam-Chyun Lin

    2018-07-01

    Full Text Available Pneumatic solenoid valve has been widely used in the vehicle control systems for meeting the rapid-reaction demand triggered by the dynamic conditions encountered during the driving course of vehicle. For ensuring the safety of human being, the reliable and effective solenoid valve is in great demand to shorten the reaction time and thus becomes the topic of this research. This numerical study chooses a commercial 3/2-way solenoid valve as the reference valve for analysing its performance. At first, CFD software Fluent is adopted to simulate the flow field associated with the valve configuration. Then, the comprehensive flow visualization is implemented to identify the locations of adverse flow patterns. Accordingly, it is found that a high-pressure region exists in the zone between the nozzle exit and the top of iron core. Thereafter, the nozzle diameter and the distance between nozzle and spool are identified as the important design parameters for improving the pressure response characteristics of valve. In conclusion, this work establishes a rigorous and systematic CFD scheme to evaluate the performance of pneumatic solenoid valve.

  2. One-way spatial integration of hyperbolic equations

    Science.gov (United States)

    Towne, Aaron; Colonius, Tim

    2015-11-01

    In this paper, we develop and demonstrate a method for constructing well-posed one-way approximations of linear hyperbolic systems. We use a semi-discrete approach that allows the method to be applied to a wider class of problems than existing methods based on analytical factorization of idealized dispersion relations. After establishing the existence of an exact one-way equation for systems whose coefficients do not vary along the axis of integration, efficient approximations of the one-way operator are constructed by generalizing techniques previously used to create nonreflecting boundary conditions. When physically justified, the method can be applied to systems with slowly varying coefficients in the direction of integration. To demonstrate the accuracy and computational efficiency of the approach, the method is applied to model problems in acoustics and fluid dynamics via the linearized Euler equations; in particular we consider the scattering of sound waves from a vortex and the evolution of hydrodynamic wavepackets in a spatially evolving jet. The latter problem shows the potential of the method to offer a systematic, convergent alternative to ad hoc regularizations such as the parabolized stability equations.

  3. One-year multicentre outcomes of transapical aortic valve implantation using the SAPIEN XT™ valve: the PREVAIL transapical study.

    Science.gov (United States)

    Walther, Thomas; Thielmann, Matthias; Kempfert, Joerg; Schroefel, Holger; Wimmer-Greinecker, Gerhard; Treede, Hendrik; Wahlers, Thorsten; Wendler, Olaf

    2013-05-01

    The study aimed to evaluate 1-year outcomes of the multicentre PREVAIL transapical (TA) study of TA-aortic valve implantation (AVI) in high-risk patients. From September 2009 to August 2010, a total of 150 patients, aged 81.6 ± 5.8 years, 40.7% female, were included at 12 European TA-AVI experienced sites. Patients received 23 (n = 36), 26 (n = 57) and 29 mm (n = 57) second-generation SAPIEN XT™ (Edwards Lifesciences, Irvine, CA, USA) valves. The mean logistic EuroSCORE was 24.3 ± 7.0, and mean Society Thoracic Surgeons score was 7.5 ± 4.4%. Survival was 91.3% at 30 days and 77.9% at 1 year. Subgroup analysis revealed survivals of 91.7/88.9, 86.0/70.2, 96.55/91.2% for patients receiving 23-, 26- and 29-mm valves at 30 days and at 1 year, respectively. Transthoracic echocardiography revealed preserved left ventricular ejection fraction and low gradients. Aortic incompetence was none in 41/48, trace 30/36, mild 22/12 and moderate in 7/4% at discharge and 1 year. Walking distance increased from 221 (postimplant) to 284 m (at 1 year, P = 0.0004). Three patients required reoperation due to increasing aortic incompetence during follow-up. Causes of mortality at 1 year were cardiac (n = 7), stroke (n = 1) and others (n = 5). The European PREVAIL multicentre trial demonstrates good functionality and good outcomes for TA-AVI using the second-generation SAPIEN XT prosthesis and the ASCENDRA-II delivery system. The 29-mm SAPIEN XT valve was successfully introduced and showed excellent results.

  4. 3D printed mitral valve models: affordable simulation for robotic mitral valve repair.

    Science.gov (United States)

    Premyodhin, Ned; Mandair, Divneet; Ferng, Alice S; Leach, Timothy S; Palsma, Ryan P; Albanna, Mohammad Z; Khalpey, Zain I

    2018-01-01

    3D printed mitral valve (MV) models that capture the suture response of real tissue may be utilized as surgical training tools. Leveraging clinical imaging modalities, 3D computerized modelling and 3D printing technology to produce affordable models complements currently available virtual simulators and paves the way for patient- and pathology-specific preoperative rehearsal. We used polyvinyl alcohol, a dissolvable thermoplastic, to 3D print moulds that were casted with liquid platinum-cure silicone yielding flexible, low-cost MV models capable of simulating valvular tissue. Silicone-moulded MV models were fabricated for 2 morphologies: the normal MV and the P2 flail. The moulded valves were plication and suture tested in a laparoscopic trainer box with a da Vinci Si robotic surgical system. One cardiothoracic surgery fellow and 1 attending surgeon qualitatively evaluated the ability of the valves to recapitulate tissue feel through surveys utilizing the 5-point Likert-type scale to grade impressions of the valves. Valves produced with the moulding and casting method maintained anatomical dimensions within 3% of directly 3D printed acrylonitrile butadiene styrene controls for both morphologies. Likert-type scale mean scores corresponded with a realistic material response to sutures (5.0/5), tensile strength that is similar to real MV tissue (5.0/5) and anatomical appearance resembling real MVs (5.0/5), indicating that evaluators 'agreed' that these aspects of the model were appropriate for training. Evaluators 'somewhat agreed' that the overall model durability was appropriate for training (4.0/5) due to the mounting design. Qualitative differences in repair quality were notable between fellow and attending surgeon. 3D computer-aided design, 3D printing and fabrication techniques can be applied to fabricate affordable, high-quality educational models for technical training that are capable of differentiating proficiency levels among users. © The Author 2017

  5. The effect of lymphatic valve morphology on fluid transport

    Science.gov (United States)

    Alexeev, Alexander; Ballard, Matthew; Nepiyushchikh, Zhanna; Dixon, Brandon

    2016-11-01

    The lymphatic vasculature is present in nearly all invertebrate tissue, and is essential in the transport of fluid and particles such as immune cells, antigens, proteins and lipids from the tissue to lymph nodes and to the venous circulation. Lymphatic vessels are made of up a series of contractile units that work together in harmony as "micro hearts" to pump fluid against a pressure gradient. Lymphatic valves are critical to this functionality, as they open and close with the oscillating pressure gradients from contractions, thus allowing flow in only one direction and leading to a net pumping effect. We use a hybrid lattice-Boltzmann lattice spring model which captures fluid-solid interactions through two-way coupling between a viscous fluid and lymphatic valves in a section of a lymphatic vessel to study the dynamics of lymphatic valves and their effect on fluid transport. Further, we investigate the effect of variations in valve geometry and material properties on fluid pumping. This work helps to increase our understanding of the mechanisms of lymphatic fluid transport, which has implications in a variety of pathologies, including cancer metastasis, autoimmunity, atherosclerosis and obesity. Support from NSF CMMI 1635133 is gratefully acknowledged.

  6. Relay Selection and Resource Allocation in One-Way and Two-Way Cognitive Relay Networks

    KAUST Repository

    Alsharoa, Ahmad M.

    2013-01-01

    In this work, the problem of relay selection and resource power allocation in one- way and two-way cognitive relay networks using half duplex channels with different relaying protocols is investigated. Optimization problems for both single

  7. Thermal fatigue behavior of valves

    International Nuclear Information System (INIS)

    Moinereau, D.; Scliffet, L.; Capion, J.C.; Genette, P.

    1991-01-01

    This paper reports that valves of pressurized water reactors are exposed to thermal shocks during transient operations. The numerous thermal shock tests performed on valves on the EDF test facilities have shown the sensibility of fillets and geometrical discontinuities to thermal fatigue: cracks can appear in those areas and grow through the valve body. Valves systems designated as level 1 must be designed to withstand fatigue up to the second isolation valve: the relevant rule is specified in the paragraph B 3500 of the French RCCM code. It is a simplified method which doesn't require finite element calculations. Many valve systems have been designed according to this rule and have been operated without accident. However, in one case, important cracks were found in the fillet of a check-valve after numerous thermal shocks. Calculation of the valve's behavior according to the RCCM code to estimate the fatigue damage resulting from thermal shocks led to a low damage factor, which doesn't agree with the experimental results. This was confirmed by new testings and showed the inadequacy of B 3500 rule for thermal transients. On this base a new rule is proposed to estimate fatigue damage resulting from thermal shocks. An experimental program has been realized to validate this rule. Axisymetrical analytical mock-ups with different geometries and one check-valve in austenitic stainless steel 316 L have been submitted to hot thermal shocks of 210 degrees C magnitude

  8. Relay Selection and Resource Allocation in One-Way and Two-Way Cognitive Relay Networks

    KAUST Repository

    Alsharoa, Ahmad M.

    2013-05-08

    In this work, the problem of relay selection and resource power allocation in one- way and two-way cognitive relay networks using half duplex channels with different relaying protocols is investigated. Optimization problems for both single and multiple relay selection that maximize the sum rate of the secondary network without degrading the quality of service of the primary network by respecting a tolerated interference threshold were formulated. Single relay selection and optimal power allocation for two-way relaying cognitive radio networks using decode-and-forward and amplify-and-forward protocols were studied. Dual decomposition and subgradient methods were used to find the optimal power allocation. The transmission process to exchange two different messages between two transceivers for two-way relaying technique takes place in two time slots. In the first slot, the transceivers transmit their signals simultaneously to the relay. Then, during the second slot the relay broadcasts its signal to the terminals. Moreover, improvement of both spectral and energy efficiency can be achieved compared with the one-way relaying technique. As an extension, a multiple relay selection for both one-way and two-way relaying under cognitive radio scenario using amplify-and-forward were discussed. A strong optimization tool based on genetic and iterative algorithms was employed to solve the 
formulated optimization problems for both single and multiple relay selection, where discrete relay power levels were considered. Simulation results show that the practical and low-complexity heuristic approaches achieve almost the same performance of the optimal relay selection schemes either with discrete or continuous power distributions while providing a considerable saving in terms of computational complexity.

  9. Minimising life cycle costs of automated valves in offshore platforms

    Energy Technology Data Exchange (ETDEWEB)

    Yli-Petays, Juha [Metso Automation do Brasil Ltda., Rio de Janeiro, RJ (Brazil); Niemela, Ismo [Metso Automation, Imatra (Finland)

    2012-07-01

    Automated process valves play an essential role in offshore platforms operation. If you are able to optimize their operation and maintenance activities you can receive extensive operational savings with minimal investment. Valves used in offshore platforms doesn't differentiate that much from the valves used in downstream but there are certain specialties, which makes the operations more challenging in offshore: Process valves are more difficult to access and maintain because of space limitations. Also spare part inventories and deliveries are challenging because of offshore platform's remote location. To overcome these challenges usage of digital positioners with diagnostic features has become more common because predictive maintenance capabilities enable possibilities to plan the maintenance activities and this way optimise the spare part orders regarding to valves. There are intelligent controllers available for control valves, automated on/off valves as well as ESD-valves and whole network of automated valves on platforms can be controlled by intelligent valve controllers. This creates many new opportunities in regards of optimized process performance or predictive maintenance point-of-view. By means of intelligent valve controllers and predictive diagnostics, condition monitoring and maintenance planning can also be performed remotely from an onshore location. Thus, intelligent valve controllers provide good way to minimize spending related to total cost of ownership of automated process valves. When purchase value of control valve represent 20% of TCO, intelligent positioner and predictive maintenance methods can enable as high as 30% savings over the life cycle of asset so basically it benefit savings higher than whole investment of monitored asset over its life cycle. This is mainly achieved through the optimized maintenance activities since real life examples has shown that with time based maintenance (preventive maintenance) approach 70% of

  10. Effects of the blockage ratio of a valve disk on loss coefficient in a butterfly valve

    International Nuclear Information System (INIS)

    Rho, Hyung Joon; Lee, Jee Keun; Choi, Hee Joo

    2008-01-01

    The loss coefficient of the butterfly valve which allows partial opening of the valve at closed position and is applicable to the small-sized pipe system with the diameter of 1 inch was measured for the variation of the valve disk blockage ratio. Two different types of the valve disk configuration to adjust the blockage ratio were considered. One was the solid type valve disk of which the diameter was changed into the smaller size rather than the pipe diameter, and the other was the perforate type valve disk on which some holes were perforated. The results from two types of valve disk were compared to identify their characteristics in the loss coefficient distributions. The loss coefficient and the controllable angle of the valve disk were decreased exponentially with the decrease of the blockage ratio. In addition, the perforate valve disk had the effect on the higher loss coefficient rather than the solid type valve disk

  11. BWR fuel assembly bottom nozzle with one-way coolant flow valve

    International Nuclear Information System (INIS)

    Taleyarkhan, R.P.

    1987-01-01

    In a nuclear reactor having a flow of coolant/moderator fluid therein, at least one fuel assembly installed in the fluid flow, the fuel assembly is described comprising in combination: a bundle of elongated fuel rods disposed in side-by-side relationship so as to form an array of spaced fuel rods; an outer tubular flow channel surrounding the fuel rods so as to direct the flow of coolant/moderator fluid along the fuel rods; bottom and top nozzles mounted at opposite ends of the flow channel and having an inlet and outlet respectively for allowing entry and exit of the flow of coolant/moderator fluid into and from the flow channel and along the fuel rods therein; and a coolant flow direction control device operatively disposed in the bottom nozzle so as to open the inlet thereof to the flow of coolant/moderator fluid in an inflow direction into the flow channel through the bottom nozzle inlet but close the inlet to the flow of coolant/moderator fluid from the flow channel through the bottom nozzle inlet upon reversal of coolant/moderator fluid flow from the inflow direction

  12. Fast Flux Test Facility primary sodium valves

    International Nuclear Information System (INIS)

    Rabe, G.B.; Ezra, B.C.

    1977-01-01

    The design and development of the valves used in the primary sodium coolant loop of the Fast Flux Test Facility is described. One tilting-disk check valve is used in the cold leg of the coolant loop. It is designed to limit flow reversal in the loop while maintaining a low pressure drop during forward flow. Two isolation valves are used in each coolant loop--one in the cold leg and one in the hot leg. They are of the motor-operated swinging-gate type. The design, analysis, and testing programs undertaken to develop and qualify these valves are described

  13. The patient inflating valve in anaesthesia and resuscitation breathing systems.

    Science.gov (United States)

    Fenton, P M; Bell, G

    2013-03-01

    Patient inflating valves combined with self-inflating bags are known to all anaesthetists as resuscitation devices and are familiar as components of draw-over anaesthesia systems. Their variants are also commonplace in transfer and home ventilators. However, the many variations in structure and function have led to difficulties in their optimal use, definition and classification. After reviewing the relevant literature, we defined a patient inflating valve as a one-way valve that closes an exit port to enable lung inflation, also permitting exhalation and spontaneous breathing, the actions being automatic. We present a new classification based on the mechanism of valve opening/closure; namely elastic recoil of a flexible flap/diaphragm, sliding spindle opened by a spring/magnet or a hollow balloon collapsed by external pressure. The evolution of these valves has been driven by the difficulties documented in critical incidents, which we have used along with information from modern International Organization for Standardization standards to identify 13 ideal properties, the top six of which are non-jamming, automatic, no bypass effect, no rebreathing or air entry at patient end, low resistance, robust and easy to service. The Ambu and the Laerdal valves have remained popular due to their simplicity and reliability. Two new alternatives, the Fenton and Diamedica valves, offer the benefits of location away from the patient while retaining a small functional dead space. They also offer the potential for greater use of hybrid continuous flow/draw-over systems that can operate close to atmospheric pressure. The reliable application of positive end-expiratory pressure/continuous positive airway pressure remains a challenge.

  14. Low noise control valve

    International Nuclear Information System (INIS)

    Christie, R.S.

    1975-01-01

    Noise is one of the problems associated with the use of any type of control valve in systems involving the flow of fluids. The advent of OSHA standards has prompted control valve manufacturers to design valves with special trim to lower the sound pressure level to meet these standards. However, these levels are in some cases too high, particularly when a valve must be located in or near an area where people are working at tasks requiring a high degree of concentration. Such locations are found around and near research devices and in laboratory-office areas. This paper describes a type of fluid control device presently being used at PPL as a bypass control valve in deionized water systems and designed to reduce sound pressure levels considerably below OSHA standards. Details of the design and construction of this constant pressure drop variable flow control valve are contained in the text and are shown in photographs and drawings. Test data taken are included

  15. Dose volume assessment of high dose rate 192IR endobronchial implants

    International Nuclear Information System (INIS)

    Cheng, B. Saw; Korb, Leroy J.; Pawlicki, Todd; Wu, Andrew

    1996-01-01

    Purpose: To study the dose distributions of high dose rate (HDR) endobronchial implants using the dose nonuniformity ratio (DNR) and three volumetric irradiation indices. Methods and Materials: Multiple implants were configured by allowing a single HDR 192 Ir source to step through a length of 6 cm along an endobronchial catheter. Dwell times were computed to deliver a dose of 5 Gy to points 1 cm away from the catheter axis. Five sets of source configurations, each with different dwell position spacings from 0.5 to 3.0 cm, were evaluated. Three-dimensional (3D) dose distributions were then generated for each source configuration. Differential and cumulative dose-volume curves were generated to quantify the degree of target volume coverage, dose nonuniformity within the target volume, and irradiation of tissues outside the target volume. Evaluation of the implants were made using the DNR and three volumetric irradiation indices. Results: The observed isodose distributions were not able to satisfy all the dose constraints. The ability to optimally satisfy the dose constraints depended on the choice of dwell position spacing and the specification of the dose constraint points. The DNR and irradiation indices suggest that small dwell position spacing does not result in a more homogeneous dose distribution for the implant. This study supports the existence of a relationship between the dwell position spacing and the distance from the catheter axis to the reference dose or dose constraint points. Better dose homogeneity for an implant can be obtained if the spacing of the dwell positions are about twice the distance from the catheter axis to the reference dose or dose constraint points

  16. The Otto-Atkinson engine. A study of fluid flow and combustion with early and late inlet valve closing

    Energy Technology Data Exchange (ETDEWEB)

    Haakansson, Henrik

    1999-10-01

    This report contains results of measurements on an Otto engine. The purpose for this work has been to do measurements of the flow in the cylinder but also measurements of the cylinder pressure have been performed. The flow measurements are made with the method Laser Doppler Velocimetry, LDV. The reason why these measurements are made at all are the pump losses that implies a lower efficiency for the Otto engine at part load. In this work two alternative ways that highly reduces the pump losses are examined. These are early inlet valve closing and late inlet valve closing. To further increase the efficiency at part load an increased compression ratio has been used together with the different valve strategies. With these two ways of operation, at a part load of about 4 - 5 IMEP{sub net}, increases of about 20% of the net indicated efficiency has been obtained. Additionally this report contains a chapter about the possible use of a variable valve actuation or timing system, VVA or VVT. Many conditions for the Otto cycle can be improved by the use of a variable valve actuation and in this chapter it is dealt with the most important ones.

  17. Effect of Endobronchial Coils vs Usual Care on Exercise Tolerance in Patients With Severe Emphysema : The RENEW Randomized Clinical Trial

    NARCIS (Netherlands)

    Sciurba, Frank C.; Criner, Gerard J.; Strange, Charlie; Shah, Pallav L.; Michaud, Gaetane; Connolly, Timothy A.; Deslee, Gaetan; Tillis, William P.; Delage, Antoine; Marquette, Charles-Hugo; Krishna, Ganesh; Kalhan, Ravi; Ferguson, J. Scott; Jantz, Michael; Maldonado, Fabien; McKenna, Robert; Majid, Adnan; Rai, Navdeep; Gay, Steven; Dransfield, Mark T.; Angel, Luis; Maxfield, Roger; Herth, Felix J. F.; Wahidi, Momen M.; Mehta, Atul; Slebos, Dirk-Jan

    2016-01-01

    IMPORTANCE Preliminary clinical trials have demonstrated that endobronchial coils compress emphysematous lung tissue and may improve lung function, exercise tolerance, and symptoms in patients with emphysema and severe lung hyperinflation. OBJECTIVE To determine the effectiveness and safety of

  18. One-way quantum computing in superconducting circuits

    Science.gov (United States)

    Albarrán-Arriagada, F.; Alvarado Barrios, G.; Sanz, M.; Romero, G.; Lamata, L.; Retamal, J. C.; Solano, E.

    2018-03-01

    We propose a method for the implementation of one-way quantum computing in superconducting circuits. Measurement-based quantum computing is a universal quantum computation paradigm in which an initial cluster state provides the quantum resource, while the iteration of sequential measurements and local rotations encodes the quantum algorithm. Up to now, technical constraints have limited a scalable approach to this quantum computing alternative. The initial cluster state can be generated with available controlled-phase gates, while the quantum algorithm makes use of high-fidelity readout and coherent feedforward. With current technology, we estimate that quantum algorithms with above 20 qubits may be implemented in the path toward quantum supremacy. Moreover, we propose an alternative initial state with properties of maximal persistence and maximal connectedness, reducing the required resources of one-way quantum computing protocols.

  19. Robust and scalable optical one-way quantum computation

    International Nuclear Information System (INIS)

    Wang Hefeng; Yang Chuiping; Nori, Franco

    2010-01-01

    We propose an efficient approach for deterministically generating scalable cluster states with photons. This approach involves unitary transformations performed on atoms coupled to optical cavities. Its operation cost scales linearly with the number of qubits in the cluster state, and photon qubits are encoded such that single-qubit operations can be easily implemented by using linear optics. Robust optical one-way quantum computation can be performed since cluster states can be stored in atoms and then transferred to photons that can be easily operated and measured. Therefore, this proposal could help in performing robust large-scale optical one-way quantum computation.

  20. Fracturing mechanics before valve-in-valve therapy of small aortic bioprosthetic heart valves.

    Science.gov (United States)

    Johansen, Peter; Engholt, Henrik; Tang, Mariann; Nybo, Rasmus F; Rasmussen, Per D; Nielsen-Kudsk, Jens Erik

    2017-10-13

    Patients with degraded bioprosthetic heart valves (BHV) who are not candidates for valve replacement may benefit from transcatheter valve-in-valve (VIV) therapy. However, in smaller-sized surgical BHV the resultant orifice may become too narrow. To overcome this, the valve frame can be fractured by a high-pressure balloon prior to VIV. However, knowledge on fracture pressures and mechanics are prerequisites. The aim of this study was to identify the fracture pressures needed in BHV, and to describe the fracture mechanics. Commonly used BHV of small sizes were mounted on a high-pressure balloon situated in a biplane fluoroscopic system with a high-speed camera. The instant of fracture was captured along with the balloon pressure. The valves were inspected for material protrusion and later dissected for fracture zone investigation and description. The valves with a polymer frame fractured at a lower pressure (8-10 atm) than those with a metal stent (19-26 atm). None of the fractured valves had elements protruding. VIV procedures in small-sized BHV may be performed after prior fracture of the valve frame by high-pressure balloon dilatation. This study provides tentative guidelines for expected balloon sizes and pressures for valve fracturing.

  1. Valve-sparing aortic root replacement†.

    Science.gov (United States)

    Koolbergen, David R; Manshanden, Johan S J; Bouma, Berto J; Blom, Nico A; Mulder, Barbara J M; de Mol, Bas A J M; Hazekamp, Mark G

    2015-02-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed. Median age was 40.3 (range: 13.4-68.6) years and 67 (69.1%) were male. Seven (7.2%) patients were younger than 18 years, the youngest being 13.4 years. Fifty-four (55.7%) had Marfan syndrome, 2 (2.1%) other fibrous tissue diseases, 15 (15.5%) bicuspid aortic valve and 3 (3.1%) had earlier Fallot repair. The reimplantation technique was used in all, with a straight vascular prosthesis in 11 (26-34 mm) and the Valsalva prosthesis in 86 (26-32 mm). Concomitant aortic valve repair was performed in 43 (44.3%), mitral valve repair in 10 (10.3%), tricuspid valve repair in 5 (5.2%) and aortic arch replacement in 3 (3.1%). Mean follow-up was 4.2 ± 2.4 years. Follow-up was complete in all. One 14-year old patient died 1.3 years post-surgery presumably of ventricular arrhythmia. One patient underwent reoperation for aneurysm of the proximal right coronary artery after 4.9 years and 4 patients required aortic valve replacement, 3 of which because of endocarditis after 0.1, 0.8 and 1.3 years and 1 because of cusp prolapse after 3.8 years. No thrombo-embolic complications occurred. Mortality, root reoperation and aortic regurgitation were absent in 88.0 ± 0.5% at 5-year follow-up. Results of valve-sparing root replacement are good, even in association with a high incidence of concomitant valve repair. Valve-sparing aortic root replacement can be performed at a very young age as long as an adult size prosthesis can be implanted. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  2. How Heart Valves Evolve to Adapt to an Extreme-Pressure System

    DEFF Research Database (Denmark)

    Amstrup Funder, Jonas; Christian Danielsen, Carl; Baandrup, Ulrik

    2017-01-01

    BACKGROUND: Heart valves which exist naturally in an extreme-pressure system must have evolved in a way to resist the stresses of high pressure. Giraffes are interesting as they naturally have a blood pressure twice that of humans. Thus, knowledge regarding giraffe heart valves may aid...... in developing techniques to design improved pressure-resistant biological heart valves. METHODS: Heart valves from 12 giraffes and 10 calves were explanted and subjected to either biomechanical or morphological examinations. Strips from the heart valves were subjected to cyclic loading tests, followed...... in giraffes than in calves, which would make giraffe valves more resistant to the high-pressure forces. However, collagen also stiffens and thickens the valves. The mitral leaflets showed similar (but mostly insignificant) trends in strength, stiffness, and collagen content....

  3. Theoretical analysis of steady state operating forces in control valves

    Directory of Open Access Journals (Sweden)

    Basavaraj Hubballi

    2018-01-01

    Full Text Available The controlling components, such as valves are used to regulate controlled fluid power. It is not always possible to calculate valve forces accurately, and with some types of valves even the existence of certain types of forces cannot be predicted with certainty. In many cases, however, the analysis can be made fairly completely and accurately. The assumption of steady state conditions is valid for the valve alone, but transient effects in the rest of the system may be large. These effects are particularly important with regard to the instability of valves, where the system may react on the valve in such a way as to make it squeal or oscillate, sometimes with large amplitude. The origin of the steady state flow force understood from a brief qualitative explanation. The following paper will summarize much of what is known about valve forces in the spool type controlling element.

  4. Fundamentals of universality in one-way quantum computation

    International Nuclear Information System (INIS)

    Nest, M van den; Duer, W; Miyake, A; Briegel, H J

    2007-01-01

    In this paper, we build a framework allowing for a systematic investigation of the fundamental issue: 'Which quantum states serve as universal resources for measurement-based (one-way) quantum computation?' We start our study by re-examining what is exactly meant by 'universality' in quantum computation, and what the implications are for universal one-way quantum computation. Given the framework of a measurement-based quantum computer, where quantum information is processed by local operations only, we find that the most general universal one-way quantum computer is one which is capable of accepting arbitrary classical inputs and producing arbitrary quantum outputs-we refer to this property as CQ-universality. We then show that a systematic study of CQ-universality in one-way quantum computation is possible by identifying entanglement features that are required to be present in every universal resource. In particular, we find that a large class of entanglement measures must reach its supremum on every universal resource. These insights are used to identify several families of states as being not universal, such as one-dimensional (1D) cluster states, Greenberger-Horne-Zeilinger (GHZ) states, W states, and ground states of non-critical 1D spin systems. Our criteria are strengthened by considering the efficiency of a quantum computation, and we find that entanglement measures must obey a certain scaling law with the system size for all efficient universal resources. This again leads to examples of non-universal resources, such as, e.g. ground states of critical 1D spin systems. On the other hand, we provide several examples of efficient universal resources, namely graph states corresponding to hexagonal, triangular and Kagome lattices. Finally, we consider the more general notion of encoded CQ-universality, where quantum outputs are allowed to be produced in an encoded form. Again we provide entanglement-based criteria for encoded universality. Moreover, we present a

  5. Valve assembly having remotely replaceable bearings

    International Nuclear Information System (INIS)

    Johnson, E.R.; Tanner, D.E.

    1980-01-01

    A valve assembly having remotely replaceable bearings is disclosed wherein a valve disc is supported within a flow duct for rotation about a pair of axially aligned bearings, one of which is carried by a spindle received within a diametral bore in the valve disc, and the other of which is carried by a bearing support block releasably mounted on the duct circumferentially of an annular collar on the valve disc coaxial with its diametrical bore. The spindle and bearing support block are adapted for remote removal to facilitate servicing or replacement of the valve disc support bearings

  6. Implementing wavelet packet transform for valve failure detection using vibration and acoustic emission signals

    International Nuclear Information System (INIS)

    Sim, H Y; Ramli, R; Abdullah, M A K

    2012-01-01

    The efficiency of reciprocating compressors relies heavily on the health condition of its moving components, most importantly its valves. Previous studies showed good correlation between the dynamic response and the physical condition of the valves. These can be achieved by employing vibration technique which is capable of monitoring the response of the valve, and acoustic emission technique which is capable of detecting the valves' material deformation. However, the relationship/comparison between the two techniques is rarely investigated. In this paper, the two techniques were examined using time-frequency analysis. Wavelet packet transform (WPT) was chosen as the multi-resolution analysis technique over continuous wavelet transform (CWT), and discrete wavelet transform (DWT). This is because WPT could overcome the high computational time and high redundancy problem in CWT and could provide detailed analysis of the high frequency components compared to DWT. The features of both signals can be extracted by evaluating the normalised WPT coefficients for different time window under different valve conditions. By comparing the normalised coefficients over a certain time frame and frequency range, the feature vectors revealing the condition of valves can be constructed. One way analysis of variance was employed on these feature vectors to test the significance of data under different valve conditions. It is believed that AE signals can give a better representation of the valve condition as it can detect both the fluid motion and material deformation of valves as compared to the vibration signals.

  7. A one-way text messaging intervention for obesity.

    Science.gov (United States)

    Ahn, Ahleum; Choi, Jaekyung

    2016-04-01

    Worldwide, there has been a startling increase in the number of people who are obese or overweight. Obesity increases the risk of cardiovascular disease and overall mortality. Mobile phone messaging is an important means of human communication globally. Because the mobile phone can be used anywhere at any time, mobile phone messaging has the potential to manage obesity. We investigated the effectiveness of a one-way text messaging intervention for obesity. Participants' body mass index and waist circumference were measured at the beginning of the programme and again after 12 weeks. The text message group received text messages about exercise, dietary intake, and general information about obesity three times a week, while the control group did not receive any text messages from the study. Of the 80 participants, 25 subjects in the text message group and 29 participants in the control group completed the study. After adjusting for baseline body mass index, the body mass index was significantly lower in the text message group than in the control group (27.9 vs. 28.3; p = 0.02). After adjusting for the baseline waist circumference, the difference of waist circumference between the text message group and control group was not significant (93.4 vs. 94.6; p = 0.13). The one-way text messaging intervention was a simple and effective way to manage obesity. The one-way text messaging intervention may be a useful method for lifestyle modification in obese subjects. © The Author(s) 2015.

  8. Door valve for fuel handling path

    International Nuclear Information System (INIS)

    Makishima, Katsuhiko.

    1969-01-01

    A door valve is provided which seals cover gas from a liquid metal cooled reactor without leakage therefrom. A threaded shaft is screwed into a heavy box press which is packed with lead. The shaft is adapted to be rotated by an electric motor or a manually operated wheel which is disposed outside of the door valve. From the box press a valve plate is suspended by four linkage bars, one for each corner. Each linkage bar is provided with two wheels which are respectively mounted at the connections with the box press and the valve plate. The wheels are carried on the horizontal grooves formed in a door valve casing. In operation the shaft rotates and travels to permit the box press and the valve plate to move into the door valve casing while the valve plate does not contact the casing. When the box press reaches the home position, the wheels drop into the recesses which are disposed at the ends of the grooves, the valve plate is carried on the valve opening, and the box press presses the valve plate to increase the tightness. The valve plate does not suffer wear as it does not over other parts. (Yamaguchi, T.)

  9. Automatic fire hydrant valve development

    International Nuclear Information System (INIS)

    Drumheller, K.

    1976-01-01

    The development of a remotely-controlled valve to operate a fire hydrant is described. Assembled from off-the-shelf components, the prototype illustrates that a valve light enough to be handled by one man is possible. However, it does not have the ruggedness or reliability needed for actual fire-fighting operations. Preliminary testing by City of Tacoma fire department personnel indicates that the valve may indeed contribute significantly to fire-fighting efficiency

  10. Gate valve performance prediction

    International Nuclear Information System (INIS)

    Harrison, D.H.; Damerell, P.S.; Wang, J.K.; Kalsi, M.S.; Wolfe, K.J.

    1994-01-01

    The Electric Power Research Institute is carrying out a program to improve the performance prediction methods for motor-operated valves. As part of this program, an analytical method to predict the stem thrust required to stroke a gate valve has been developed and has been assessed against data from gate valve tests. The method accounts for the loads applied to the disc by fluid flow and for the detailed mechanical interaction of the stem, disc, guides, and seats. To support development of the method, two separate-effects test programs were carried out. One test program determined friction coefficients for contacts between gate valve parts by using material specimens in controlled environments. The other test program investigated the interaction of the stem, disc, guides, and seat using a special fixture with full-sized gate valve parts. The method has been assessed against flow-loop and in-plant test data. These tests include valve sizes from 3 to 18 in. and cover a considerable range of flow, temperature, and differential pressure. Stem thrust predictions for the method bound measured results. In some cases, the bounding predictions are substantially higher than the stem loads required for valve operation, as a result of the bounding nature of the friction coefficients in the method

  11. NRC valve performance test program - check valve testing

    International Nuclear Information System (INIS)

    Jeanmougin, N.M.

    1987-01-01

    The Valve Performance Test Program addresses the current requirements for testing of pressure isolation valves (PIVs) in light water reactors. Leak rate monitoring is the current method used by operating commercial power plants to survey the condition of their PIVs. ETEC testing of three check valves (4-inch, 6-inch, and 12-inch nominal diameters) indicates that leak rate testing is not a reliable method for detecting impending valve failure. Acoustic emission monitoring of check valves shows promise as a method of detecting loosened internals damage. Future efforts will focus on evaluation of acoustic emission monitoring as a technique for determining check valve condition. Three gate valves also will be tested to evaluate whether the check valve results are applicable to gate type PIVs

  12. Transcatheter, valve-in-valve transapical aortic and mitral valve implantation, in a high risk patient with aortic and mitral prosthetic valve stenoses

    Directory of Open Access Journals (Sweden)

    Harish Ramakrishna

    2015-01-01

    Full Text Available Transcatheter valve implantation continues to grow worldwide and has been used principally for the nonsurgical management of native aortic valvular disease-as a potentially less invasive method of valve replacement in high-risk and inoperable patients with severe aortic valve stenosis. Given the burden of valvular heart disease in the general population and the increasing numbers of patients who have had previous valve operations, we are now seeing a growing number of high-risk patients presenting with prosthetic valve stenosis, who are not potential surgical candidates. For this high-risk subset transcatheter valve delivery may be the only option. Here, we present an inoperable patient with severe, prosthetic valve aortic and mitral stenosis who was successfully treated with a trans catheter based approach, with a valve-in-valve implantation procedure of both aortic and mitral valves.

  13. Treatment of multiple-level tracheobronchial stenosis secondary to endobronchial tuberculosis using bronchoscopic balloon dilatation with topical mitomycin-C.

    Science.gov (United States)

    Faisal, Mohamed; Harun, Hafaruzi; Hassan, Tidi M; Ban, Andrea Y L; Chotirmall, Sanjay H; Abdul Rahaman, Jamalul Azizi

    2016-04-14

    Tracheobronchial stenosis is a known complication of endobronchial tuberculosis. Despite antituberculous and steroid therapy, the development of bronchial stenosis is usually irreversible and requires airway patency to be restored by either bronchoscopic or surgical interventions. We report the use of balloon dilatation and topical mitomycin-C to successful restore airway patency. We present a 24-year old lady with previous pulmonary tuberculosis and laryngeal tuberculosis in 2007 and 2013 respectively who presented with worsening dyspnoea and stridor. She had total left lung collapse with stenosis of both the upper trachea and left main bronchus. She underwent successful bronchoscopic balloon and manual rigid tube dilatation with topical mitomycin-C application over the stenotic tracheal segment. A second bronchoscopic intervention was performed after 20 weeks for the left main bronchus stenosis with serial balloon dilatation and topical mitomycin-C application. These interventions led to significant clinical and radiographic improvements. This case highlights that balloon dilatation and topical mitomycin-C application should be considered in selected patients with tracheobronchial stenosis following endobronchial tuberculosis, avoiding airway stenting and invasive surgical intervention.

  14. Magnetostatic Analysis of a Pinch Mode Magnetorheological Valve

    Directory of Open Access Journals (Sweden)

    Gołdasz Janusz

    2017-09-01

    Full Text Available The study deals with the pinch mode of magnetorheological (MR fluids’ operation and its application in MR valves. By applying the principle in MR valves a highly non-uniform magnetic field can be generated in flow channels in such a way to solidify the portion of the material that is the nearest to the flow channel’s walls. This is in contrary to well-known MR flow mode valves. The authors investigate a basic pinch mode valve in several fundamental configurations, and then examine their magnetic circuits through magnetostatic finite-element (FE analysis. Flux density contour maps are revealed and basic performance figures calculated and analysed. The FE analysis results yield confidence in that the performance of MR pinch mode devices can be effectively controlled through electromagnetic means.

  15. Efficient one-way quantum computations for quantum error correction

    International Nuclear Information System (INIS)

    Huang Wei; Wei Zhaohui

    2009-01-01

    We show how to explicitly construct an O(nd) size and constant quantum depth circuit which encodes any given n-qubit stabilizer code with d generators. Our construction is derived using the graphic description for stabilizer codes and the one-way quantum computation model. Our result demonstrates how to use cluster states as scalable resources for many multi-qubit entangled states and how to use the one-way quantum computation model to improve the design of quantum algorithms.

  16. Autonomous booster device of a safety valve

    International Nuclear Information System (INIS)

    Namand, H.

    1983-01-01

    The invention concerns an autonomous booster device of a protection safety valve of a pressure vessel. The valve comprises a hollow structure, a seat connected with a mobile flap forming one piece with a stem and a calibration spring bearing on the stem and on the valve structure to maintain the flap bearing on the seat. The stem of the flap is prolongated in a box forming one piece with the valve structure and receives an added push of a spring. The box acts as a pressure device of which the piston can exercise on the stem a push opposite to and larger than the spring one. The feeding device of the pressure box is finally described in detail [fr

  17. The effectiveness of endobronchial therapy in patients with chemo-resistant tuberculosis when specific process is localized in the lungs apical segments

    Directory of Open Access Journals (Sweden)

    V. M. Khlystun

    2017-08-01

    Full Text Available Objective – to study the effectiveness of the additional methods of endobronchial pathology treatment in patients with chemo-resistant tuberculosis (CRTB of lungs, that aimed to treat a specific process in bronchi when destructions are localized in the apical segments (S1+2 of lungs. Materials and methods. In order to investigate effectiveness of the additional methods of endobronchial pathology treatment of bronchial mucosa 79 patients with CRTB of lungs were examined. They were divided into 3 groups: basic 1 group, which included 27 patients who were treated by using antimycobacterial drugs endobronchial introduction to S1+2 with further implementation of intraorganic electrophoresis in S1+2 zone in combination with systemic receiving of antimycobacterial drugs; the comparison basic 2 group 27 patients who were treated with systemic antimycobacterial therapy in combination with antituberculosis drugs inhalations; and the group included – 25 patients who received only systemic antimycobacterial therapy. Groups were compared by the severity of the process, age and gender. Tracheobronchial tree fiber-bronchoscopy in patients with CRTB of lungs was carried out on the basis of phthisiology and pulmonology department of ZSMU in communal institution "Zaporizhzhia regional antituberculosis dispensary", by the author on their own. Character of bronchial mucosa was examined under anesthesia by fiber-bronchoscopes of company "Olympus" (Japan. Bronchial tree pathology was described according to N. V. Shesterynoy, A. N. Kaliuk (1975 classification. Results of the study were processed with modern methods of analysis on a personal computer with using the Statistical Package license software Statistica® for Windows 6.0 (StatSoft Inc., № AXXR712 D833214FAN5. Results. The use of antimycobacterial drugs endobronchial introduction to S1+2 with further implementation of intraorganic electrophoresis in S1+2 zone contributed significantly increase the

  18. 49 CFR Appendix A to Part 180 - Internal Self-closing Stop Valve Emergency Closure Test for Liquefied Compressed Gases

    Science.gov (United States)

    2010-10-01

    ... internal self-closing stop valve's lever, piston, or other valve indicator has moved to the closed position. 2. On pump-actuated pressure differential internal valves, the three-way toggle valve handle or its...

  19. System and method for controlling engine knock using electro-hydraulic valve actuation

    Science.gov (United States)

    Brennan, Daniel G

    2013-12-10

    A control system for an engine includes a knock control module and a valve control module. The knock control module adjusts a period that one or more of an intake valve and an exhaust valve of a cylinder are open based on engine knock corresponding to the cylinder. The valve control module, based on the adjusted period, controls the one or more of the intake valve and the exhaust valve using one or more hydraulic actuators.

  20. Additively Manufactured Main Fuel Valve Housing

    Science.gov (United States)

    Eddleman, David; Richard, Jim

    2015-01-01

    Selective Laser Melting (SLM) was utilized to fabricate a liquid hydrogen valve housing typical of those found in rocket engines and main propulsion systems. The SLM process allowed for a valve geometry that would be difficult, if not impossible to fabricate by traditional means. Several valve bodies were built by different SLM suppliers and assembled with valve internals. The assemblies were then tested with liquid nitrogen and operated as desired. One unit was also burst tested and sectioned for materials analysis. The design, test results, and planned testing are presented herein.

  1. Valve selection handbook engineering fundamentals for selecting the right valve design for every industrial flow application

    CERN Document Server

    Smith, Peter

    2004-01-01

    Valves are the components in a fluid flow or pressure system that regulate either the flow or the pressure of the fluid. They are used extensively in the process industries, especially petrochemical. Though there are only four basic types of valves, there is an enormous number of different kinds of valves within each category, each one used for a specific purpose. No other book on the market analyzes the use, construction, and selection of valves in such a comprehensive manner.-Covers new environmentally-conscious equipment and practices, the most important hot-button issue in the p

  2. A symmetric safety valve

    International Nuclear Information System (INIS)

    Burtraw, Dallas; Palmer, Karen; Kahn, Danny

    2010-01-01

    How to set policy in the presence of uncertainty has been central in debates over climate policy. Concern about costs has motivated the proposal for a cap-and-trade program for carbon dioxide, with a 'safety valve' that would mitigate against spikes in the cost of emission reductions by introducing additional emission allowances into the market when marginal costs rise above the specified allowance price level. We find two significant problems, both stemming from the asymmetry of an instrument that mitigates only against a price increase. One is that most important examples of price volatility in cap-and-trade programs have occurred not when prices spiked, but instead when allowance prices collapsed. Second, a single-sided safety valve may have unintended consequences for investment. We illustrate that a symmetric safety valve provides environmental and welfare improvements relative to the conventional one-sided approach.

  3. Heart valve surgery

    Science.gov (United States)

    ... replacement; Valve repair; Heart valve prosthesis; Mechanical valves; Prosthetic valves ... surgery. Your heart valve has been damaged by infection ( endocarditis ). You have received a new heart valve ...

  4. Cavitation guide for control valves

    Energy Technology Data Exchange (ETDEWEB)

    Tullis, J.P. [Tullis Engineering Consultants, Logan, UT (United States)

    1993-04-01

    This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation.

  5. Cavitation guide for control valves

    International Nuclear Information System (INIS)

    Tullis, J.P.

    1993-04-01

    This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation

  6. Design And Analysis Of A Camless Valve Mechanism For I.C Engines Using Rotary Disc Valves

    Directory of Open Access Journals (Sweden)

    Vivek Jitendra Panchal

    2017-09-01

    Full Text Available It is the object of the presented paper to provide an electromechanical rotary valve actuating system for opening and closing valves of an internal combustion engine capable of separately controlling both the inlet and exhaust valve operations of each individual cylinder in a multi-cylinder engine. This indicates that only one valve will be required for each cylinder of the engine. Previously published versions of this concept require a separate valve for intake and exhaust in each cylinder. The system provides an alternative to the camshaft assembly in an attempt to overcome the limitations and inadequacies inevitably posed by a fully mechanical system. The prototype development is approached in a theoretical manner beginning with the conceptualization and design of a rotating disk with a notches and corresponding closure surfaces to open and close the flow path. The actuated disk and notch design is then refined and followed by the design of an inlet and exhaust manifold to correspond to the valve design and the theorizing and design of a sealing gasket. The rotating speed of the valve is determined by a general idling speed and can be varied to provide variable valve timing with the motor. The final assembly eliminates a majority of the moving parts currently used in camshaft systems like the cam camshaft rocker arm push rod and springs and results in a significantly lighter valve actuation system. By eliminating the translatory motion of valves the problem of valves slamming on the valve seats at high velocities is eliminated thus greatly reducing engine wear.

  7. Gastric and Endobronchial Metastases in a Case of Lobular Breast Cancer

    Directory of Open Access Journals (Sweden)

    G.S. Fernandes

    2013-11-01

    Full Text Available Background: Invasive lobular carcinoma (ILC is the second most common histological type of invasive breast carcinoma, preceded only by infiltrating ductal carcinoma, which has clinical, biological and molecular distinctions. These distinctions imply a different metastatic behavior between the histology of these 2 types of breast cancer. Case Presentation: We report the case of a 51-year-old woman with breast cancer with ILC histology, diagnosed at an early stage. In the course of her disease, recurrences in the gastric mucosa and endobronchial area occurred. The treatment she received is described herein. Conclusion: This is a case of ILC with unusual metastases. The absence of E-cadherin is related to the carcinogenesis of ILC and probably to these patterns of metastasis as well.

  8. Transcatheter mitral valve repair in osteogenesis imperfecta associated mitral valve regurgitation.

    Science.gov (United States)

    van der Kley, Frank; Delgado, Victoria; Ajmone Marsan, Nina; Schalij, Martin J

    2014-08-01

    Osteogenesis imperfecta is associated with increased prevalence of significant mitral valve regurgitation. Surgical mitral valve repair and replacement are feasible but are associated with increased risk of bleeding and dehiscence of implanted valves may occur more frequently. The present case report describes the outcomes of transcatheter mitral valve repair in a patient with osteogenesis imperfecta. A 60 year-old patient with osteogenesis imperfecta and associated symptomatic moderate to severe mitral regurgitation underwent transthoracic echocardiography which showed a nondilated left ventricle with preserved systolic function and moderate to severe mitral regurgitation. On transoesophageal echocardiography the regurgitant jet originated between the anterolateral scallops of the anterior and posterior leaflets (A1-P1). Considering the comorbidities associated with osteogenesis imperfecta the patient was accepted for transcatheter mitral valve repair using the Mitraclip device (Abbott vascular, Menlo, CA). Under fluoroscopy and 3D transoesophageal echocardiography guidance, a Mitraclip device was implanted between the anterolateral and central scallops with significant reduction of mitral regurgitation. The postoperative evolution was uneventful. At one month follow-up, transthoracic echocardiography showed a stable position of the Mitraclip device with no mitral regurgitation. Transcatheter mitral valve repair is feasible and safe in patients with osteogenesis imperfecta and associated symptomatic significant mitral regurgitation. Copyright © 2014 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  9. 250 kV aim for hvdc valves

    Energy Technology Data Exchange (ETDEWEB)

    1966-06-01

    Development now being carried out by ASEA is aimed at increasing the normal operating voltage for a mercury arc valve to 250 kV dc. The maximum direct voltage per valve group, with one valve in each arm of the bridge, is 125 kV for equipment already in operation in New Zealand, Japan, and Konti Scan. Valves for 130 kV and 133 kV operation are under construction for the Vancouver and the Pacific Intertie 1 links.

  10. Latest design of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kurzhofer, U.; Stolte, J.; Weyand, M.

    1996-12-01

    Babcock Sempell, one of the most important valve manufacturers in Europe, has delivered valves for the nuclear power industry since the beginning of the peaceful application of nuclear power in the 1960s. The latest innovation by Babcock Sempell is a gate valve that meets all recent technical requirements of the nuclear power technology. At the moment in the United States, Germany, Sweden, and many other countries, motor-operated gate and globe valves are judged very critically. Besides the absolute control of the so-called {open_quotes}trip failure,{close_quotes} the integrity of all valve parts submitted to operational forces must be maintained. In case of failure of the limit and torque switches, all valve designs have been tested with respect to the quality of guidance of the gate. The guidances (i.e., guides) shall avoid a tilting of the gate during the closing procedure. The gate valve newly designed by Babcock Sempell fulfills all these characteristic criteria. In addition, the valve has cobalt-free seat hardfacing, the suitability of which has been proven by friction tests as well as full-scale blowdown tests at the GAP of Siemens in Karlstein, West Germany. Babcock Sempell was to deliver more than 30 gate valves of this type for 5 Swedish nuclear power stations by autumn 1995. In the presentation, the author will report on the testing performed, qualifications, and sizing criteria which led to the new technical design.

  11. [Pannus Formation Six-years after Aortic and Mitral Valve Replacement with Tissue Valves;Report of a Case].

    Science.gov (United States)

    Nakamura, Makoto; Muraoka, Arata; Aizawa, Kei; Akutsu, Hirohiko; Kurumisawa, Soki; Misawa, Yoshio

    2015-07-01

    A 77-year-old man presented with exertional dyspnea. He had undergone aortic and mitral valve replacement with tissue valves 6-years earlier. The patient's hemoglobin level was 9.8 g/dl and serum aspartate aminotransferase (70 mU/ml) and lactate dehydrogenase (1,112 mU/ml) were elevated. Echocardiography revealed stenosis of the prosthetic valve in the aortic position with peak flow velocity of 3.8 m/second and massive mitral regurgitation. The patient underwent repeat valve replacement. Pannus formation around both implanted valves was observed. The aortic valve orifice was narrowed by the pannus, and one cusp of the prosthesis in the mitral position was fixed and caused the regurgitation, but they were free from cusp laceration or calcification. The patient's postoperative course was uneventful, and he continues to do well 14 months after surgery.

  12. Non intrusive check valve diagnostics at Bruce A

    International Nuclear Information System (INIS)

    Marsch, S.P.

    1997-01-01

    Bruce A purchased non intrusive check valve diagnostic equipment in 1995 to ensure operability and availability of critical check valves in the Station. Diagnostics can be used to locate and monitor check valve degradation modes. Bruce A initiated a pilot program targeting check valves with flow through them and ones that completed open or close cycles. Approaches to determine how to confirm operability of passive check valves using non intrusive techniques were explored. A sample population of seventy-three check valves was selected to run the pilot program on prior to complete implementation. The pilot program produced some significant results and some inconclusive results. The program revealed a major finding that check valve performance modeling is required to ensure continuous operability of check valves. (author)

  13. Non intrusive check valve diagnostics at Bruce A

    Energy Technology Data Exchange (ETDEWEB)

    Marsch, S.P. [Ontario Hydro, Bruce Nuclear Generating Station A, Tiverton, ON (Canada)

    1997-07-01

    Bruce A purchased non intrusive check valve diagnostic equipment in 1995 to ensure operability and availability of critical check valves in the Station. Diagnostics can be used to locate and monitor check valve degradation modes. Bruce A initiated a pilot program targeting check valves with flow through them and ones that completed open or close cycles. Approaches to determine how to confirm operability of passive check valves using non intrusive techniques were explored. A sample population of seventy-three check valves was selected to run the pilot program on prior to complete implementation. The pilot program produced some significant results and some inconclusive results. The program revealed a major finding that check valve performance modeling is required to ensure continuous operability of check valves. (author)

  14. Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside.

    Science.gov (United States)

    Saxon, John T; Allen, Keith B; Cohen, David J; Chhatriwalla, Adnan K

    2018-01-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient-prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient-prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions.

  15. Radiological findings of congenital urethral valves

    International Nuclear Information System (INIS)

    Yeon, Kyung Mo; Kook, Shin Ho

    1990-01-01

    Congenital urethral valve is the common cause of hydronephrosis in newborn infants and the most common cause of bladder outlet obstruction in male children. We reviewed and analysed radiological findings and associated anomalies of 16 cases of congenital urethral valve which were examined during the period from January 1985 to December 1989. The most frequent age was under one year old (56%). The main symptoms were urinary dribbing (37.5%), weak stream (25%) and urinary frequency and incontinence (25%). Anterior urethral valve (AUV) was 5 cases (31%) and posterior urethral valve (PUV) was 11 cases(69%), in which 10 cases were Type I and one case was Type III. Bladder wall thickening was seen in all cases and its severity was partly correlated with the degree of vesicoureteral reflux (VUR). VUR was observed in 12 cases (75%), and relatively severe in older age group. The degree of VUR was milder in AUV than PUV. Hydronephrosis was more severe in PUV than in anterior one, and its degree was correlated with the severity of VUR. Associated anomalies were ectopic urethral opening (2 cases), PDA (1 case), congenital megacolon (1 case) and patent urachus (1 case) in PUV. So early diagnosis and treatment of congenital urethral valve is essential to the prevention of renal damage

  16. Bistable fluidic valve is electrically switched

    Science.gov (United States)

    Fiet, O.; Salvinski, R. J.

    1970-01-01

    Bistable control valve is selectively switched by direct application of an electrical field to divert fluid from one output channel to another. Valve is inexpensive, has no moving parts, and operates on fluids which are relatively poor electrical conductors.

  17. Outcome of endobronchial electrocautery versus external beam radiotherapy or both together in the palliative management of non-small cell lung cancer

    Directory of Open Access Journals (Sweden)

    Samah M. Shehata

    2013-01-01

    Conclusions: The replacement of external radiation with bronchoscopic therapy may not be a recommended option, but its addition to XRT may be a relatively simple method of augmenting the symptom palliative effect, providing higher response rates for re-expansion of collapsed lung and reducing endobronchial obstruction endoscopically.

  18. ADAM®/SIPLUG®: An innovative valve monitoring system

    International Nuclear Information System (INIS)

    Muñoz, L.; Krell, M.

    2012-01-01

    Optimized maintenance strategies are a key aspect for safe and undisturbed plant operation. Innovative valve service solutions, e.g. valve diagnostics can support this in an efficient way. The ADAM®/SIPLUG® valve monitoring system allows full online monitoring of valves and actuators with automatic evaluation and assessment. Especially for safety-related and operation-related valves this provides valuable information on components condition to ensure proper function and contribute to optimization of maintenance strategies as well as effective maintenance performance. The new SIPLUG®-4 modules are the evolutionary solution for valve diagnosis at the Motor Control Center (MCC). As the SIPLUG®-4 can be installed directly in the MCC outgoing actuator power cable it allows an easy installation in existing switchgear cabinets. Measurement at MCC means also zero effort for performance of diagnostics reducing the number of on-site activities. This results in decrease of maintenance costs and dose rates for deployed personnel. The ADAM® evaluation software and database was developed in parallel with the hardware. It provides automatic analysis of the monitoring results using the limit values specified for the valves. The measured data can be transmitted via the power plant’s local area network to the ADAM® data server, if the SIPLUG® online hardware is installed. With the mobile solution, the data can be transmitted via serial or USB interface to a PC or notebook. With this solution all measurement information will be available immediately in the offices of plant engineers. Also, with SIPLUG® online all operations of valves can be automatically recorded. More than 25 years of experience in various plants worldwide show that the application of ADAM®/SIPLUG® valve diagnostics solution leads to increased plant safety and availability. Some of the references for ADAM®/SIPLUG® are Germany, Switzerland, Brazil, Spain and Eastern Europe. (author)

  19. One-Way Deficit and Quantum Phase Transitions in XX Model

    Science.gov (United States)

    Wang, Yao-Kun; Zhang, Yu-Ran

    2018-02-01

    Quantum correlations including entanglement and quantum discord have drawn much attention in characterizing quantum phase transitions. Quantum deficit originates in questions regarding work extraction from quantum systems coupled to a heat bath (Oppenheim et al. Phys. Rev. Lett. 89, 180402, 2002). It links quantum thermodynamics with quantum correlations and provides a new standpoint for understanding quantum non-locality. In this paper, we evaluate the one-way deficit of two adjacent spins in the bulk for the XX model. In the thermodynamic limit, the XX model undergoes a first order transition from fully polarized to a critical phase with quasi-long-range order with decrease of quantum parameter. We find that the one-way deficit becomes nonzero after the critical point. Therefore, the one-way deficit characterizes the quantum phase transition in the XX model.

  20. Analysis of aortic root surgery with composite mechanical aortic valve conduit and valve-sparing reconstruction.

    Science.gov (United States)

    Dias, Ricardo Ribeiro; Mejia, Omar Asdrubal Vilca; Fiorelli, Alfredo Inácio; Pomerantzeff, Pablo Maria Alberto; Dias, Altamiro Ribeiro; Mady, Charles; Stolf, Noedir Antonio Groppo

    2010-01-01

    Comparative analysis of early and late results of aortic root reconstruction with aortic valve sparing operations and the composite mechanical valve conduit replacement. From November 2002 to September 2009, 164 consecutive patients with mean age 54 ± 15 years, 115 male, underwent the aortic root reconstruction (125 mechanical valve conduit replacements and 39 valve sparing operations). Sixteen percent of patients had Marfan syndrome and 4.3% had bicuspid aortic valve. One hundred and forty-four patients (88%) were followed for a mean period of 41.1 ± 20.8 months. The hospital mortality was 4.9%, 5.6% in operations with valved conduits and 2.6% in the valve sparing procedures (P valve sparing operations, respectively (95% CI = 70% - 95%, P = 0.001), (95% CI = 82% - 95% P = 0.03) and (95% CI = 81% - 95%, P = 0.03). Multivariate analysis showed that creatinine greater than 1.4 mg/dl, Cabrol operation and renal dialysis were predictors of mortality, respectively, with occurrence chance of 6 (95% CI = 1.8 - 19.5, P = 0.003), 12 (95% CI = 3 - 49.7, P = 0.0004) and 16 (95% CI = 3.6 - 71.3, P = 0.0002). The aortic root reconstruction has a low early and late mortality, high survival free of complications and low need for reoperation. During the late follow-up, valve sparing aortic root reconstructions presented fewer incidences of bleeding, thromboembolic events and endocarditis.

  1. Control Valve

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Wayne R.

    2018-03-20

    A control valve includes a first conduit having a first inlet and a first outlet and defining a first passage; a second conduit having a second inlet and a second outlet and defining a second passage, the second conduit extending into the first passage such that the second inlet is located within the first passage; and a valve plate disposed pivotably within the first passage, the valve plate defining a valve plate surface. Pivoting of the valve plate within the first passage varies flow from the first inlet to the first outlet and the valve plate is pivotal between a first position and a second position such that in the first position the valve plate substantially prevents fluid communication between the first passage and the second passage and such that in the second position the valve plate permits fluid communication between the first passage and the second passage.

  2. Imaging techniques in aortic valve and root surgery

    NARCIS (Netherlands)

    Regeer, M.V.

    2017-01-01

    Aortic valve sparing surgery for aortic regurgitation and/or aortopathy serves as an alternative to aortic valve and root replacement. One of the advantages of aortic valve sparing surgery over conventional replacement is that there is no need for life-long anticoagulation, which is particularly

  3. Demonstration of Multisetting One-Way Einstein-Podolsky-Rosen Steering in Two-Qubit Systems

    Science.gov (United States)

    Xiao, Ya; Ye, Xiang-Jun; Sun, Kai; Xu, Jin-Shi; Li, Chuan-Feng; Guo, Guang-Can

    2017-04-01

    Einstein-Podolsky-Rosen (EPR) steering describes the ability of one party to remotely affect another's state through local measurements. One of the most distinguishable properties of EPR steering is its asymmetric aspect. Steering can work in one direction but fail in the opposite direction. This type of one-way steering, which is different from the symmetry concepts of entanglement and Bell nonlocality, has garnered much interest. However, an experimental demonstration of genuine one-way EPR steering in the simplest scenario, i.e., one that employs two-qubit systems, is still lacking. In this Letter, we experimentally demonstrate one-way EPR steering with multimeasurement settings for a class of two-qubit states, which are still one-way steerable even with infinite settings. The steerability is quantified by the steering radius, which represents a necessary and sufficient steering criterion. The demonstrated one-way steering in the simplest bipartite quantum system is of fundamental interest and may provide potential applications in one-way quantum information tasks.

  4. A fault-tolerant one-way quantum computer

    International Nuclear Information System (INIS)

    Raussendorf, R.; Harrington, J.; Goyal, K.

    2006-01-01

    We describe a fault-tolerant one-way quantum computer on cluster states in three dimensions. The presented scheme uses methods of topological error correction resulting from a link between cluster states and surface codes. The error threshold is 1.4% for local depolarizing error and 0.11% for each source in an error model with preparation-, gate-, storage-, and measurement errors

  5. Vent-induced prosthetic leaflet thrombosis treated by open-heart valve-in-valve implantation.

    Science.gov (United States)

    Stamm, Christof; Pasic, Miralem; Buz, Semih; Hetzer, Roland

    2015-09-01

    A patient required emergency mitral valve replacement and extracorporeal membrane oxygenation (ECMO) support for acute biventricular failure. The left ventricular (LV) vent inserted via the left upper pulmonary vein induced thrombotic immobilization of a prosthetic valve leaflet, with significant intra-prosthesis regurgitation after ECMO explantation. Therefore, the left atrium was opened on the beating heart during conventional extracorporeal circulation, all prosthesis leaflets were excised and a 29-mm expandable Edwards Sapien prosthesis was inserted within the scaffold of the original prosthesis under direct vision. This case illustrates the benefits and potential problems of LV venting on ECMO support, and a rapid and safe way of replacing the prosthesis leaflets in a critical situation. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  6. Massive haemoptysis after radiotherapy in inoperable non-small cell lung carcinoma: is endobronchial brachytherapy really a risk factor?

    International Nuclear Information System (INIS)

    Langendijk, J.A.; Tjwa, M.K.T.; Jong, J.M.A. de; Velde, G.P.M. ten; Wouters, E.F.M.

    1998-01-01

    Background and purpose: This retrospective study was conducted to investigate whether endobronchial brachytherapy (EBB) is a risk factor for massive haemoptysis in patients primarily treated by a combination of EBB and external irradiation (XRT) for NSCLC. Materials and methods: The records of 938 patients with inoperable NSCLC who were treated with XRT and/or EBB were reviewed. The patients were divided into five groups as follows: group XRT, treated by XRT alone (n=421); group XRTelig, treated by XRT but eligible for EBB (n=419); group XRTEBB, primarily treated with EBB+XRT (n=62); group EBBrec, treated by EBB for recurrence after XRT (n=23); and group EBB, treated by EBB alone (n=13). EBB was delivered using HDR. Patients with bronchoscopy-proven endobronchial tumour in the proximal airways, i.e. the trachea, the main bronchus or lobar bronchus were considered eligible for EBB. Results: One hundred one out of 938 patients (10.8%) died from massive haemoptysis. The incidence was 4.3% in group XRT, 13.1% in group XRTelig and 25.4% in group XRTEBB. The differences between groups XRT and XRTelig as well as between groups XRTelig and XRTEBB were statistically significant (P<0.01). The incidence of massive haemoptysis depended significantly on the fraction size of brachytherapy. When two fractions of 7.5 Gy or a single fraction of 10 Gy were used, 11.1% of the patients died from massive haemoptysis. However, when a single dose of 15 Gy was used, 47.8% died from massive haemoptysis. In the multivariate analysis, a single dose of 15 Gy EBB was the most important prognostic factor for massive haemoptysis. Conclusion: XRT+EBB as primary treatment for NSCLC does not lead to a higher risk of massive haemoptysis as compared to XRT alone when fraction sizes for EBB of 7.5 or 10 Gy are used. However, the risk of massive haemoptysis increases dramatically when a fraction size of 15 Gy is used. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  7. Endobronchial ultrasound-guided transbronchial needle aspiration is a sensitive method to evaluate patients who should not undergo pulmonary metastasectomy†

    DEFF Research Database (Denmark)

    Eckardt, Jens; Licht, Peter Bjørn

    2015-01-01

    metastasectomy with systematic sampling of mediastinal lymph nodes for histological evaluation. RESULTS: One hundred and three eligible patients were referred for EBUS-TBNA during a 4-year period. The primary cancers were located in the colon/rectum (n = 64), kidney (n = 16) and other sites (n = 23). EBUS......OBJECTIVES: Pulmonary metastasectomy is considered an effective treatment in selected patients with extrapulmonary cancer and oligometastatic disease. We know that the presence of mediastinal lymph node metastases reduces survival significantly, but the mediastinum is rarely evaluated before...... metastasectomy in these patients. We prospectively evaluated how endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) could identify metastases to the mediastinal lymph nodes in patients referred for pulmonary metastasectomy. METHODS: All patients with extrapulmonary cancer...

  8. Valving for controlling a fluid-driven reciprocating apparatus

    Science.gov (United States)

    Whitehead, John C.

    1995-01-01

    A pair of control valve assemblies for alternately actuating a pair of fluid-driven free-piston devices by using fluid pressure communication therebetween. Each control valve assembly is switched by a pressure signal depending on the state of its counterpart's piston. The communication logic is arranged to provide overlap of the forward strokes of the pistons, so that at least one of the pair will always be pressurized. Thus, uninterrupted pumping of liquid is made possible from a pair of free-piston pumps. In addition, the speed and frequency of piston stroking is entirely dependent on the mechanical power load applied. In the case of a pair of pumps, this enables liquid delivery at a substantially constant pressure over the full range of flow rates, from zero to maximum flow. Each of the valve assemblies uses an intake-exhaust valve and a signal valve with the signal valve of one pump being connected to be pressure responsive to the piston of the opposite cylinder or pump.

  9. Active combustion flow modulation valve

    Science.gov (United States)

    Hensel, John Peter; Black, Nathaniel; Thorton, Jimmy Dean; Vipperman, Jeffrey Stuart; Lambeth, David N; Clark, William W

    2013-09-24

    A flow modulation valve has a slidably translating hollow armature with at least one energizable coil wound around and fixably attached to the hollow armature. The energizable coil or coils are influenced by at least one permanent magnet surrounding the hollow armature and supported by an outer casing. Lorentz forces on the energizable coils which are translated to the hollow armature, increase or decrease the flow area to provide flow throttling action. The extent of hollow armature translation depends on the value of current supplied and the direction of translation depends on the direction of current flow. The compact nature of the flow modulation valve combined with the high forces afforded by the actuator design provide a flow modulation valve which is highly responsive to high-rate input control signals.

  10. Mitral Valve Disease

    Science.gov (United States)

    ... for mitral valve replacement—mechanical valves (metal) or biological valves (tissue). The principal advantage of mechanical valves ... small risk of stroke due to blood clotting. Biological valves usually are made from animal tissue. Biological ...

  11. Check valves aging assessment

    International Nuclear Information System (INIS)

    Haynes, H.D.

    1991-01-01

    In support of the NRC Nuclear Plant Aging Research (NPAR) program, the Oak Ridge National Laboratory (ORNL) has carried out an assessment of several check value diagnostic monitoring methods, in particular, those based on measurements of acoustic emission, ultrasonics, and magnetic flux. The evaluations have focussed on the capabilities of each method to provide information useful in determining check valve aging and service wear effects, check valve failures, and undesirable operating modes. This paper describes the benefits and limitations associated with each method and includes recent laboratory and field test data, including data obtained from the vendors who recently participated in a comprehensive series of tests directed by a nuclear industry users group. In addition, as part of the ORNL Advanced Diagnostic Engineering Research and Development Center (ADEC), two novel nonintrusive monitoring methods were developed that provide several unique capabilities. These methods, based on external ac- an dc-magnetic monitoring are also described. None of the examined methods could, by themselves, monitor both the instantaneous position and motion of check valve internals and valve leakage; however, the combination of acoustic emission monitoring with one of the other methods provides the means to determine vital check valve operational information

  12. Sealing a Loosely Fitting Valve Assembly

    Science.gov (United States)

    Goff, L.; Tellier, G.

    1986-01-01

    Double-ring seal avoids expense of remachining or redesigning valve parts. Mating fittings on valve sealed by pair of rings - one O-ring and backup ring. Backup ring fills relatively large gap between parts. Prevents softer O-ring from being pushed into and through gap.

  13. A STUDY OF INDICATIONS, COMPLICATIONS OF PROSTHETIC VALVES AND PROGNOSIS AFTER TREATMENT OF STUCK VALVE

    Directory of Open Access Journals (Sweden)

    Y. V. Subba Reddy

    2017-03-01

    Full Text Available BACKGROUND Implantation of prosthetic cardiac valves to treat haemodynamically significant valvular diseases has become common; however, it is associated with complications. Thus, this study was intended to evaluate the indications for implantation of prosthetic valve and complications after its implantation and prognosis after treatment of one of its complication, i.e. stuck valve. MATERIALS AND METHODS This was a single-centered study wherein 50 patients who came to the emergency department with stuck valve were assessed. The 2D echocardiography was performed in all patients. Thrombolysis was done and the gradients were reassessed. Further response to treatment and development of complications before and after treatment were observed. RESULTS Of total patients, 60% were females. Mean age group was 30-40 yrs. Most of them were asymptomatic for 6 years and there was lack of compliance in 90% of patients. Most common indication for valve replacement was mitral stenosis (60% followed by mitral regurgitation (20%, aortic regurgitation and aortic stenosis (10% and combined mitral and tricuspid regurgitation (10%. Commonest valve was St. Jude (90%. Pannus was observed in 10% patients and thrombus was observed in 50% patients. Most patients had gradients 45/20 mmHg across mitral valve. In about 90% patients, gradients decreased after thrombolysis (12/5 mmHg. The complications after thrombolysis were hemiparesis (4%, death before thrombolysis (6% and death after thrombolysis (4%. CONCLUSION Considering these results, it can be concluded that prosthetic valves are seldom associated with some complications. Further, thrombolysis can be effective in patients with prosthetic valve thrombosis.

  14. Detection technology research on the one-way clutch of automatic brake adjuster

    Science.gov (United States)

    Jiang, Wensong; Luo, Zai; Lu, Yi

    2013-10-01

    In this article, we provide a new testing method to evaluate the acceptable quality of the one-way clutch of automatic brake adjuster. To analysis the suitable adjusting brake moment which keeps the automatic brake adjuster out of failure, we build a mechanical model of one-way clutch according to the structure and the working principle of one-way clutch. The ranges of adjusting brake moment both clockwise and anti-clockwise can be calculated through the mechanical model of one-way clutch. Its critical moment, as well, are picked up as the ideal values of adjusting brake moment to evaluate the acceptable quality of one-way clutch of automatic brake adjuster. we calculate the ideal values of critical moment depending on the different structure of one-way clutch based on its mechanical model before the adjusting brake moment test begin. In addition, an experimental apparatus, which the uncertainty of measurement is ±0.1Nm, is specially designed to test the adjusting brake moment both clockwise and anti-clockwise. Than we can judge the acceptable quality of one-way clutch of automatic brake adjuster by comparing the test results and the ideal values instead of the EXP. In fact, the evaluation standard of adjusting brake moment applied on the project are still using the EXP provided by manufacturer currently in China, but it would be unavailable when the material of one-way clutch changed. Five kinds of automatic brake adjusters are used in the verification experiment to verify the accuracy of the test method. The experimental results show that the experimental values of adjusting brake moment both clockwise and anti-clockwise are within the ranges of theoretical results. The testing method provided by this article vividly meet the requirements of manufacturer's standard.

  15. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    Science.gov (United States)

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  16. Tight valve

    International Nuclear Information System (INIS)

    Guedj, F.

    1987-01-01

    This sealed valve is made with a valve seat, an axial valve with a rod fixed to its upper end, a thick bell surrounding the rod and welded by a thin join on the valve casing, a threated ring screwed onto the upper end of the rod and a magnet or electromagnet rotating the ring outside the bell [fr

  17. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI). ...

  18. Valve-sparing and valve-replacing techniques for aortic root replacement in patients with Marfan syndrome: Analysis of early outcome.

    Science.gov (United States)

    Volguina, Irina V; Miller, D Craig; LeMaire, Scott A; Palmero, Laura C; Wang, Xing Li; Connolly, Heidi M; Sundt, Thoralf M; Bavaria, Joseph E; Dietz, Harry C; Milewicz, Dianna M; Coselli, Joseph S

    2009-05-01

    A prospective, international registry study was initiated to provide contemporary comparative data on short-term clinical outcomes after aortic valve-sparing and aortic valve-replacing root operations in patients with Marfan syndrome. The purpose of this initial report is to describe the study design and to compare early outcomes in the first 151 enrolled patients. We assessed 30-day outcomes in 151 patients who met strict Ghent diagnostic criteria for Marfan syndrome and underwent aortic root replacement with either valve-replacing (n = 46) or valve-sparing techniques (n = 105) at one of 18 participating centers. In the valve replacement group, a mechanical composite valve graft was used in 39 (85%) patients and a bioprosthetic valve in 7 (15%). In the valve-sparing group, David V procedures were performed in 57 (54%) patients, David I in 38 (36%), David IV in 8 (8%), Florida sleeve in 1 (1%), and Yacoub remodeling in 1 (1%). No in-hospital or 30-day deaths occurred. Despite longer crossclamp and cardiopulmonary bypass times in the valve-sparing group, there were no significant between-group differences in postoperative complications. Thirty-day valve-related complications occurred in 2 (4%) patients undergoing valve replacement and in 3 (3%) undergoing valve-sparing procedures (P = .6). The analysis of early outcomes revealed that valve-sparing techniques were the most common approach to root replacement in patients with Marfan syndrome in these centers. The complexity of valve-sparing root replacement did not translate into any demonstrable adverse early outcomes. Subsequent analysis will compare the 3-year durability of these two surgical approaches.

  19. Experimental substantiation of the design of a prosthetic heart valve for «valve-in-valve» implantation

    Directory of Open Access Journals (Sweden)

    K. Yu. Klyshnikov

    2017-01-01

    Full Text Available The aim of the study was to perform a series of in vitro tests of a prototype of the developing heart valve prosthesis to evaluate its functional characteristics. Materials and methods. In this work we have used the frames and full prototypes of the prosthesis, consisting of a stent-like stainless steel support frame with mounted biological leaflets and cover. The authors evaluated the calculated and experimental forces necessary for the displacement of the sutureless implanted prosthesis using the test machine under uniaxial tension. The risk of defects and damages to the supporting framework as a result of implantation was evaluated by scanning electron microscopy. The hydrodynamic characteristics of the prosthesis were investigated under physiological conditions and «valvein-valve» implantation. Evaluation of the ergonomics and applicability of the proposed construction on the cadaver heart model of cattle was carried out. Results. As a result of the forces assessment, it was found that the force required to shear the prosthesis was 3.12 ± 0.37 N, while the calculated value was 1.7 N, which is significantly lower than the obtained value. The comparison of the images obtained with small and large magnifications demonstrated the absence of critical surface defects. Additional analysis under the super-large magnifications also did not reveal problem areas. During the hydrodynamic study, it was shown that the average transplant gradient increased slightly from 2.8–3.4 to 3.2–4.5 mm Hg for the initial prosthesis and the «valve-in-valve» complex, respectively. The decrease of the effective orifice area was 6–9% relative to the initial one. Evaluation of the implantation technique demonstrated the consistency of the approach: the use of the developed holder in combination with the balloon implantation system made it possible to position the prosthesis throughout the procedure. Conclusion. The series of tests demonstrates the consistency

  20. [Tricuspid valve insufficiency: what should be done?].

    Science.gov (United States)

    von Segesser, L K; Stauffer, J C; Delabays, A; Chassot, P G

    1998-12-01

    Tricuspid regurgitation is relatively common. Due to the progress made in echocardiography, its diagnosis is in general made readily and in reliable fashion. Basically one has to distinguish between functional tricuspid valve regurgitation due to volume and/or pressure overload of the right ventricle with intact valve structures versus tricuspid valve regurgitation due to pathologic valve structures. The clear identification of the regurgitation mechanism is of prime importance for the treatment. Functional tricuspid valve regurgitation can often be improved by medical treatment of heart failure, and eventually a tricuspid valve plasty can solve the problem. However, the presence of pathologic tricuspid valve structures makes in general more specific plastic surgical procedures and even prosthetic valve replacements necessary. A typical example for a structural tricuspid valve regurgitation is the case of a traumatic papillary muscle rupture. Due to the sudden onset, this pathology is not well tolerated and requires in general surgical reinsertion of the papillary muscle. In contrast, tricuspid valve regurgitation resulting from chronic pulmonary embolism with pulmonary artery hypertension, can be improved by pulmonary artery thrombendarteriectomy and even completely cured with an additional tricuspid annuloplasty. However, tricuspid regurgitations due to terminal heart failure are not be addressed with surgery directed to tricuspid valve repair or replacement. Heart transplantation, dynamic cardiomyoplasty or mechanical circulatory support should be evaluated instead.

  1. An application of the valve-leak monitoring system to the valves for the improved Korean standard nuclear power plant (KSNP+)

    International Nuclear Information System (INIS)

    Byeong-yeol AHN; Dae-sik CHOI; Sang-kook CHUNG

    2006-01-01

    The loss of steam due to valve leakage leads to the inefficiency of power generation at the nuclear power plants. Under the normal conditions of plant operation, it is difficult to detect valve leaks early enough to prevent consequential damages and losses. The capability of timely detection allows the plant adequate time to prepare repair plans, which would ultimately result in efficient power production. Therefore, timing of detection is one of the most important factors in dealing with valve leakage problems. The VLMS has been developed to meet such an industrial demand. It provides early detection of valve leakage by real-time monitoring through the acoustic sensors installed on the inlet and the outlet of the valve. The KSNP+ utilizes the VLMS to enhance the performance and maintenance of major valves at plants. The VLMS will enable the plant to detect the leakage of valve at an early stage. It can reduce the steam losses and save related valve maintenance cost by performing fast diagnosis of valve leakage. (authors)

  2. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John G; Bleiziffer, Sabine

    2014-01-01

    for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING......, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation...... and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83...

  3. Dysfunction of an On-X Heart Valve by Pannus.

    Science.gov (United States)

    Abad, Cipriano; Urso, Stefano; Gomez, Elsa; De la Vega, Maria

    2016-09-01

    A 68-year-old woman with a history of previous double-valve replacement with On-X mechanical heart valves presented with clinical, echocardiographic and cardiac catheterization signs of obstruction of the On-X tricuspid heart valve prosthesis. The patient was successfully reoperated, but at surgery the valve was seen to be invaded by an abnormal overgrowth of pannus that blocked one of the leaflets. A small amount of non-obstructive fresh thrombus was also observed. The valve was successfully replaced with a biological heart valve prosthesis. The patient was discharged home, and is doing well four months after the operation, when echocardiography demonstrated normal function in the tricuspid valve. The present case represents the first ever report of pannus formation and subsequent dysfunction in an On-X heart valve, and also the first case of tricuspid valve malfunction and obstruction using this type of heart valve substitute.

  4. Plunger with simple retention valve

    International Nuclear Information System (INIS)

    Fekete, A.V.

    1987-01-01

    This patent describes a positive displacement retention valve apparatus in which the actual flow equals the theoretical maximum flow through the retention valve. The apparatus includes, in combination, a confined fluid flow conduit, a piston adapted for reciprocal movement within the fluid flow conduit between upstream and downstream limit positions, piston reciprocating means, and pressure responsive check valve means located upstream with respect to the piston in the fluid flow conduit. The pressure responsive check valve means operable to permit fluid flow therethrough in a downstream direction toward the piston, and to preclude fluid flow therethrough in an opposite direction. The piston is composed of parts which are relatively movable with respect to one another. The piston includes a simple retention valve consisting of a plug means, a cylinder having a minimum and a maximum internal cross section flow area therein and being reciprocal within the confined fluid flow conduit, and a seat on the cylinder for the plug means. The piston reciprocating means are operatively connected to the plug means

  5. Testing of one-inch UF{sub 6} cylinder valves under simulated fire conditions

    Energy Technology Data Exchange (ETDEWEB)

    Elliott, P.G. [Martin Marietta Energy Systems, Inc., Paducah, KY (United States)

    1991-12-31

    Accurate computational models which predict the behavior of UF{sub 6} cylinders exposed to fires are required to validate existing firefighting and emergency response procedures. Since the cylinder valve is a factor in the containment provided by the UF{sub 6} cylinder, its behavior under fire conditions has been a necessary assumption in the development of such models. Consequently, test data is needed to substantiate these assumptions. Several studies cited in this document provide data related to the behavior of a 1-inch UF{sub 6} cylinder valve in fire situations. To acquire additional data, a series of tests were conducted at the Paducah Gaseous Diffusion Plant (PGDP) under a unique set of test conditions. This document describes this testing and the resulting data.

  6. Multidetector computed tomography sizing of bioprosthetic valves: guidelines for measurement and implications for valve-in-valve therapies

    International Nuclear Information System (INIS)

    Rajani, R.; Attia, R.; Condemi, F.; Webb, J.; Woodburn, P.; Hodson, D.; Nair, A.; Preston, R.; Razavi, R.; Bapat, V.N.

    2016-01-01

    Aim: To describe a technique for bioprosthetic multidetector computed tomography (MDCT) sizing and to compare MDCT-derived values against manufacturer-provided sizing. Materials and methods: Fourteen bioprosthetic stented valves commonly used in the aortic valve position were evaluated using a Philips 256 MDCT system. All valves were scanned using a dedicated cardiac CT protocol with a four-channel electrocardiography (ECG) simulator. Measurements were made of major and minor axes and the area and perimeter of the internal stent using varying reconstruction kernels and window settings. Measurements derived from MDCT (MDCT ID) were compared against the stent internal diameter (Stent ID) as provided by the valve manufacturer and the True ID (Stent ID + insertion of leaflets). All data were collected and analysed using SPSS for Mac (version 21). Results: The mean difference between the MDCT ID and Stent ID was 0.6±1.9 mm (r=0.649, p=0.012) and between MDCT ID and True ID 2.1±2 mm (r=0.71, p=0.005). There was no difference in the major (p=0.90), minor (p=0.87), area (p=0.92), or perimeter (p=0.92) measurements when sharp, standard, and detailed stent kernels were used. Similarly, the measurements remained consistent across differing windowing levels. Conclusion: Bioprosthetic stented valves may be reliably sized using MDCT in patients requiring valve-in-valve (VIV) interventions where the valve type and size are unknown. In these cases, clinicians should be aware that MDCT has a tendency to overestimate the True ID size. - Highlights: • Cardiac CT is likely to be ideally suited for bioprosthetic aortic valve sizing for valve in valve procedures. • We compared MDCT sizing for 14 varying bioprosthetic aortic valves across varying window settings and reconstruction kernels. • We provide “normal” MDCT sizing for varying valves and show their relationship to surgical sizing. • Bioprosthetic valves may be reliably sized by MDCT but require adjustment owing to

  7. Isolation valve control device for nuclear power plant

    International Nuclear Information System (INIS)

    Yukinori, Shigeru.

    1990-01-01

    The present invention provides an isolation valve control device for detecting pipeline rupture accidents in a BWR type nuclear power plant at an early stage to close an isolation valve thereby reducing the amout of radioactivity released to the circumstance. That is, isolation valves are disposed in the pipeline for each of the systems in the nuclear power plant and flow ratemeters are disposed to at least two positions in each of the pipelines. If a meaningful difference is shown for the measured values by these flow ratemeters, the isolation valve is closed. In this way, if pipeline rupture such as leak before break (LBB) is caused to a portion of a system pipelines, the measured value from the flow ratemeters at the downstream of the pipeline is lowered. Accordingly, when a meaningful difference is formed between the value of the flow ratematers at the upstream and the downstream, occurrence of pipe rutpture between both of the flow ratemeters can be detected. As a result, the isolation valves of the system can be closed. According to the present invention, it is possible to detect the pipeline rupture at an early stage irrespective of the kind of the systems, diameter of the pipelines and the magnitude of the ruptured area, and the isolation valve can be closed. (I.S.)

  8. Valve Concepts for Microfluidic Cell Handling

    Directory of Open Access Journals (Sweden)

    M. Grabowski

    2010-01-01

    Full Text Available In this paper we present various pneumatically actuated microfluidic valves to enable user-defined fluid management within a microfluidic chip. To identify a feasible valve design, certain valve concepts are simulated in ANSYS to investigate the pressure dependent opening and closing characteristics of each design. The results are verified in a series of tests. Both the microfluidic layer and the pneumatic layer are realized by means of soft-lithographic techniques. In this way, a network of channels is fabricated in photoresist as a molding master. By casting these masters with PDMS (polydimethylsiloxane we get polymeric replicas containing the channel network. After a plasma-enhanced bonding process, the two layers are irreversibly bonded to each other. The bonding is tight for pressures up to 2 bar. The valves are integrated into a microfluidic cell handling system that is designed to manipulate cells in the presence of a liquid reagent (e.g. PEG – polyethylene glycol, for cell fusion. For this purpose a user-defined fluid management system is developed. The first test series with human cell lines show that the microfluidic chip is suitable for accumulating cells within a reaction chamber, where they can be flushed by a liquid medium.

  9. Efficiency of aortic valve commissurotomy for congenital aortic valve stenosis in pediatric population

    Directory of Open Access Journals (Sweden)

    А. А. Лукьянов

    2015-10-01

    Full Text Available Background. This study was designed to evaluate short-term and long-term outcomes after open aortic valve commissurotomy in the pediatric patients at our center over a period of 10 years. Methods. A retrospective study of 94 patients who underwent open surgical commissurotomy because of aortic valve stenosis between 2003 and 2013 is presented. Follow-up time was in the range of 1 to 7 years. Results. The open aortic valve commissurotomy combined with debridement of leaflet free edge 36.1 %, LVOT myectomy 11.7%, leaflet suture plastic 7.4%, modified Konno procedure 6.3%, Brom's aortoplasty 4.2% was performed for all patients. Average cardiopulmonary bypass time was 59.2 30.7 min. Median aortic cross-clamping time was 31.52 15.1 min. Hospital complications were observed in 38.2% of cases. ICU time was in the range of 1 to 31 (mean 3.2 5.1 day. Artificial lung ventilation time varied from 2 to 76 (mean 15.3 18.3 hours. Inotropic support was needed in 26.5% of cases. Mean hospital stay time was 17.1 7.3 days. At follow-up between 2 and 7 years, reoperations were required for 3 patients who underwent a Ross procedure. Conclusions. The results evidence that open surgical commissurotomy is an effective way of treatment for aortic valve stenosis, considering the accuracy of plasty and additional techniques of leaflet correction. The best children age group for this type of operation is from first to five years of life.

  10. Self-actuated Polymeric Valve for Autonomous Sensing and Mixing

    DEFF Research Database (Denmark)

    Häfliger, Daniel; Marie, Rodolphe Charly Willy; Boisen, Anja

    2005-01-01

    We present an autonomously operated microvalve array for chemical sensing and mixing, which gains the actuation energy from a chemical reaction on the valve structure. An 8-μm-thick flapper valve made in SU-8 is coated with stress-loaded Al on one side and Ti on the other side. The metal films ke...... a reservoir. Calculations reveal that valve operation with stress originating from biochemical processes will require considerable enhancement of the actuation efficiency.......We present an autonomously operated microvalve array for chemical sensing and mixing, which gains the actuation energy from a chemical reaction on the valve structure. An 8-μm-thick flapper valve made in SU-8 is coated with stress-loaded Al on one side and Ti on the other side. The metal films keep...

  11. Fast-acting valve actuator

    Science.gov (United States)

    Cho, Nakwon

    1980-01-01

    A fast-acting valve actuator utilizes a spring driven pneumatically loaded piston to drive a valve gate. Rapid exhaust of pressurized gas from the pneumatically loaded side of the piston facilitates an extremely rapid piston stroke. A flexible selector diaphragm opens and closes an exhaust port in response to pressure differentials created by energizing and de-energizing a solenoid which controls the pneumatic input to the actuator as well as selectively providing a venting action to one side of the selector diaphragm.

  12. Valve for the mechanical isolation of a pipe to take up a test probe

    International Nuclear Information System (INIS)

    Uecker, D.F.

    1976-01-01

    A valve is introduced for application in a pipe in which a test probe is arranged. The valve serves to isolate the pipe in a gas-tight way, thus preventing the escape of radioactive gas or dust during operation in a nuclear reactor. (TK) [de

  13. Valve Disease

    Science.gov (United States)

    ... blood. There are 4 valves in the heart: tricuspid, pulmonary, mitral, and aortic. Two types of problems can disrupt blood flow through the valves: regurgitation or stenosis. Regurgitation is also called insufficiency or incompetence. Regurgitation happens when a valve doesn’ ...

  14. Transcatheter pulmonary valve replacement by hybrid approach using a novel polymeric prosthetic heart valve: proof of concept in sheep.

    Directory of Open Access Journals (Sweden)

    Ben Zhang

    Full Text Available Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach.We designed a novel polymeric trileaflet transcatheter pulmonary valve with a balloon-expandable stent, and the valve leaflets were made of 0.1-mm expanded polytetrafluoroethylene (ePTFE coated with phosphorylcholine. We chose glutaraldehyde-treated bovine pericardium valves as control. Pulmonary valve stents were implanted in situ by a hybrid transapical approach in 10 healthy sheep (8 for polymeric valve and 2 for bovine pericardium valve, weighing an average of 22.5±2.0 kg. Angiography and cardiac catheter examination were performed after implantation to assess immediate valvular functionality. After 4-week follow-up, angiography, echocardiography, computed tomography, and cardiac catheter examination were used to assess early valvular function. One randomly selected sheep with polymeric valve was euthanized and the explanted valved stent was analyzed macroscopically and microscopically.Implantation was successful in 9 sheep. Angiography at implantation showed all 9 prosthetic valves demonstrated orthotopic position and normal functionality. All 9 sheep survived at 4-week follow-up. Four-week follow-up revealed no evidence of valve stent dislocation or deformation and normal valvular and cardiac functionality. The cardiac catheter examination showed the peak-peak transvalvular pressure gradient of the polymeric valves was 11.9±5.0 mmHg, while that of two bovine pericardium valves were 11 and 17 mmHg. Gross morphology demonstrated good opening and closure characteristics. No thrombus or calcification was seen macroscopically

  15. Endobronchial neurogenic tumor: A combination of traumatic neuroma and neurofibroma

    Directory of Open Access Journals (Sweden)

    Amit Tandon

    2017-01-01

    Full Text Available Traumatic neuromas are uncommon and benign lesions arising from a peripheral nerve injury during surgery. Here we describe a case with histopathologic features of both a traumatic neuroma and neurofibroma in a patient without integumentary physical exam findings nor prior surgical history. A 54 year old male was admitted for surgical debridement of a foot ulcer. During pre-operative evaluation and review of imaging multiple CT scans revealed a stable, 4 mm endobronchial lesion in the left lower lobe. Given history of nicotine abuse, bronchoscopy was performed. Bronchoscopy showed a pearly, polypoid lesion. Histopathological results showed strong positivity for S-100 protein and spindle cell proliferation. Repeat CT chest showed no new lesions in the bronchial tree. The rarity of this case is noted not only by the limited number of bronchial neurogenic tumors, but the combined features in this case of a traumatic neuroma and neurofibroma which has not been described.

  16. Magnon Valve Effect between Two Magnetic Insulators

    Science.gov (United States)

    Wu, H.; Huang, L.; Fang, C.; Yang, B. S.; Wan, C. H.; Yu, G. Q.; Feng, J. F.; Wei, H. X.; Han, X. F.

    2018-03-01

    The key physics of the spin valve involves spin-polarized conduction electrons propagating between two magnetic layers such that the device conductance is controlled by the relative magnetization orientation of two magnetic layers. Here, we report the effect of a magnon valve which is made of two ferromagnetic insulators (YIG) separated by a nonmagnetic spacer layer (Au). When a thermal gradient is applied perpendicular to the layers, the inverse spin Hall voltage output detected by a Pt bar placed on top of the magnon valve depends on the relative orientation of the magnetization of two YIG layers, indicating the magnon current induced by the spin Seebeck effect at one layer affects the magnon current in the other layer separated by Au. We interpret the magnon valve effect by the angular momentum conversion and propagation between magnons in two YIG layers and conduction electrons in the Au layer. The temperature dependence of the magnon valve ratio shows approximately a power law, supporting the above magnon-electron spin conversion mechanism. This work opens a new class of valve structures beyond the conventional spin valves.

  17. Space Shuttle OMS engine valve technology. [Orbital Maneuvering System

    Science.gov (United States)

    Wichmann, H.

    1974-01-01

    Valve technology program to determine shutoff valve concepts suitable for the Orbital Maneuvering System (OMS) engine of the Space Shuttle. The tradeoff studies selected the electric torque motor operated dual poppet and ball valves as the most desirable valve concepts for the OMS Engine Shutoff Valve. A prototype of one of these concepts was built and subjected to a design verification program. A number of unique features were designed to include the required contamination insensitivity, operating fluid compatibility, decontamination capability, minimum maintenance requirement and long service life capability.

  18. 241-AN-A valve pit manifold valves and position indication acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    VANDYKE, D.W.

    1999-08-25

    This document describes the method used to test design criteria for gear actuated ball valves installed in 241-AN-A Valve Pit located at 200E Tank Farms. The purpose of this procedure is to demonstrate the following: Equipment is properly installed, labeled, and documented on As-Built drawings; New Manifold Valves in the 241-AN-A Valve Pit are fully operable using the handwheel of the valve operators; New valve position indicators on the valve operators will show correct valve positions; New valve position switches will function properly; and New valve locking devices function properly.

  19. Aortic Valve Stenosis

    Science.gov (United States)

    ... most cases, doctors don't know why a heart valve fails to develop properly, so it isn't something you could have prevented. Calcium buildup on the valve. With age, heart valves may accumulate deposits of calcium (aortic valve ...

  20. Performance Analysis of a Forecasting Relocation Model for One-Way Carsharing

    Directory of Open Access Journals (Sweden)

    Ganjar Alfian

    2017-06-01

    Full Text Available A carsharing service can be seen as a transport alternative between private and public transport that enables a group of people to share vehicles based at certain stations. The advanced carsharing service, one-way carsharing, enables customers to return the car to another station. However, one-way implementation generates an imbalanced distribution of cars in each station. Thus, this paper proposes forecasting relocation to solve car distribution imbalances for one-way carsharing services. A discrete event simulation model was developed to help evaluate the proposed model performance. A real case dataset was used to find the best simulation result. The results provide a clear insight into the impact of forecasting relocation on high system utilization and the reservation acceptance ratio compared to traditional relocation methods.

  1. Non-return valve, more particularly for PWR

    International Nuclear Information System (INIS)

    Panet, M.; Martin, R.

    1987-01-01

    This non-return valve has a tubular body containing an axially sliding piston. The sliding piston delimits a cylinder cooperating with a valve seat to block fluid flow in one direction and a flow restrictor downstream of the seat in the other direction [fr

  2. Experimental demonstration of deterministic one-way quantum computing on a NMR quantum computer

    OpenAIRE

    Ju, Chenyong; Zhu, Jing; Peng, Xinhua; Chong, Bo; Zhou, Xianyi; Du, Jiangfeng

    2008-01-01

    One-way quantum computing is an important and novel approach to quantum computation. By exploiting the existing particle-particle interactions, we report the first experimental realization of the complete process of deterministic one-way quantum Deutsch-Josza algorithm in NMR, including graph state preparation, single-qubit measurements and feed-forward corrections. The findings in our experiment may shed light on the future scalable one-way quantum computation.

  3. Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration for Staging of Patients with Non-Small Cell Lung Cancer without Mediastinal Involvement at Positron Emission Tomography-Computed Tomography

    DEFF Research Database (Denmark)

    Naur, Therese Maria Henriette; Konge, Lars; Clementsen, Paul Frost

    2017-01-01

    BACKGROUND: Staging of lung cancer is essential to the treatment, which is curative only in cases of localized disease. Previous studies have suggested that endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is unnecessary when positron emission tomography-computed tomog...

  4. Method of effecting fast turbine valving for improvement of power system stability

    International Nuclear Information System (INIS)

    Park, R.H.

    1981-01-01

    As a improved way of effecting fast valving of turbines of power system steam-electric generating units for the purpose of improving the stability of power transmission over transmission circuits to which their generators make connection, when stability is threatened by line faults and certain other stability endangering events, the heretofore employed and/or advocated practice of automatically closing intercept valves at fastest available closing speed in response to a fast valving signal, and thereafter automatically fully reopening them in a matter of seconds, is modified by providing to reopen the valves only partially to and thereafter retain them at a preset partially open position. For best results the process of what can be termed sustained partial reopening is so effected as to result in its completion within a fraction of a second following the peak of the first forward swing of the generator rotor. Control valves may be either held open, or automatically fully or partly closed and thereafter fully opened in a preprogrammed manner, or automatically moved to and thereafter held in a partly closed position, by means of a preprogrammed process of repositioning in which the valves may optionally be first fully or partly closed and thereafter partly reopened. Avoidance of discharge of steam through high pressure safety valves can be had with use of suitably controlled power operated valves that discharge steam to the condenser or to atmosphere. Where there is an intermediate pressure turbine that is supplied with superheated steam, use of sustained partial control valve closure, if employed, is supplemented by provision for reduction of rate of heat release within the steam generator in order to protect the reheater from overheating. As a way to restrict increase of reheat pressure of fossil fuel installations, and to minimize increase in the msr (Moisture separator-reheater) pressure of nuclear units, provision is optionally made of normally closed by-pass v

  5. Valve assembly

    International Nuclear Information System (INIS)

    Sandling, M.

    1981-01-01

    An improved valve assembly, used for controlling the flow of radioactive slurry, is described. Radioactive contamination of the air during removal or replacement of the valve is prevented by sucking air from the atmosphere through a portion of the structure above the valve housing. (U.K.)

  6. Mitral Valve Stenosis

    Science.gov (United States)

    ... the left ventricle from flowing backward. A defective heart valve fails to either open or close fully. Risk factors Mitral valve stenosis is less common today than it once was because the most common cause, ... other heart valve problems, mitral valve stenosis can strain your ...

  7. Structural valve deterioration in a starr-edwards mitral caged-disk valve prosthesis.

    Science.gov (United States)

    Aoyagi, Shigeaki; Tayama, Kei-Ichiro; Okazaki, Teiji; Shintani, Yusuke; Kono, Michitaka; Wada, Kumiko; Kosuga, Ken-Ichi; Mori, Ryusuke; Tanaka, Hiroyuki

    2013-01-01

    The durability of the Starr-Edwards (SE) mitral caged-disk valve, model 6520, is not clearly known, and structural valve deterioration in the SE disk valve is very rare. Replacement of the SE mitral disk valve was performed in 7 patients 23-40 years after implantation. Macroscopic examination of the removed disk valves showed no structural abnormalities in 3 patients, in whom the disk valves were removed at valves excised >36 years after implantation in 4 patients. Disk fracture, a longitudinal split in the disk along its circumference at the site of incorporation of the titanium ring, was detected in the valves removed 36 and 40 years after implantation, respectively, and many cracks were also observed on the outflow aspect of the disk removed 40 years after implantation. Disk fracture and localized disk wear were found in the SE mitral disk valves implanted >36 years previously. The present results suggest that SE mitral caged-disk valves implanted >20 years previously should be carefully followed up, and that those implanted >30 years previously should be electively replaced with modern prosthetic valves

  8. Piezoelectric and Sensitivity Evaluation of Acoustic Emission Sensors for Nuclear Power Plant Valve

    International Nuclear Information System (INIS)

    Lee, Sang-Guk; Lee, Sun-Ki; Park, Sung-Keun; Kim, Myung-Ki

    2008-01-01

    A lot of valves are used in the power plant. The operation safety test and the valve inside leak detection are implemented on the valve which has a great impact on the safe operation of the plant. While input and output pressure measurement using a pressure gauge, temperature change and the humidity measurement, and pressure-resistant test are used for the valve leak detection, there are many problems such as the difficulty of the real time measurement at the minute leak situation, complexity of the pressure gauge correction and the process of the pressure measurement, and the reliability of the measured value. Therefore, it is necessary to develop the valve leak detection system using the acoustic emission (AE) method which is fast and accurate, and allows the real time measurement and evaluation of the minute leak situation. The valve leak detection method using the AE method is a convenient way to detect the sound of the leak outside the valve in case of existing leak inside of the valve, and the research is in progress recently to apply the method to the power plant valve

  9. Numerical Model of Air Valve For Computation of One-dimensional Flow

    Directory of Open Access Journals (Sweden)

    Daniel HIMR

    2014-06-01

    Full Text Available The paper is focused on a numerical simulation of unsteady flow in a pipeline. The special attention is paid to a numerical model of an air valve, which has to include all possible regimes: critical/subcritical inflow and critical/subcritical outflow of air. Thermodynamic equation of subcritical mass flow was simplified to get more friendly shape of relevant equations, which enables easier solution of the problem.

  10. Bentall Operation with Valved Homograft Conduit

    Science.gov (United States)

    Choudhary, Shiv K.; Talwar, Sachin; Kumar, A. Sampath

    2000-01-01

    Lesions of the ascending aorta associated with aortic valve disease are usually treated by implanting a prosthetic valved conduit (Bentall procedure). In this report, we present our experience in which a valved homograft conduit was used for the procedure. Six patients underwent a Bentall procedure with the use of a cryopreserved valved homograft conduit. Two of the patients had annuloaortic ectasia, 2 had Marfan syndrome, and 1 had an atherosclerotic aneurysm of the aorta. One patient had severe aortic stenosis due to a bicuspid aortic valve, along with an aneurysm and localized dissection of the ascending aorta. In all of the patients, the aortic annulus was substantially dilated, with accompanying moderate-to-severe aortic regurgitation. A standard procedure was performed with moderate hypothermia, cardiopulmonary bypass, and aortic and bicaval cannulation. The ascending aorta and the aortic valve were replaced with a cryopreserved valved homograft conduit (aortic in 5 patients and pulmonary in 1). The native coronary ostia were anastomosed directly to the homograft. Echocardiography, which was performed intraoperatively, before discharge from the hospital, and at follow-up visits (1 to 36 months), revealed good valve function without dilatation of the homograft conduits. There was 1 late death due to Aspergillus fumigatus endocarditis, 6 months postoperatively. In 1 patient, magnetic resonance imaging performed at 24 months revealed normal caliber of the homograft conduit. We conclude that the Bentall procedure can be performed, safely and with excellent results, using cryopreserved homograft conduits. PMID:11198310

  11. Aortic valve replacement and the stentless Freedom SOLO valve

    NARCIS (Netherlands)

    Wollersheim, L.W.L.M.

    2016-01-01

    Aortic valve stenosis has become the most prevalent valvular heart disease in Europe and North America, and is generally caused by age-related calcification of the aortic valve. For most patients, severe symptomatic aortic stenosis needs effective mechanical relief in the form of valve replacement

  12. Optimal valve location in long oil pipelines

    OpenAIRE

    Grigoriev, A.; Grigorieva, N.V.

    2007-01-01

    We address the valve location problem, one of the basic problems in design of long oil pipelines. Whenever a pipeline is depressurized, the shutoff valves block the oil flow and seal the damaged part of the pipeline. Thus, the quantity of oil possibly contaminating the area around the pipeline is determined by the volume of the damaged section of the pipeline between two consecutive valves. Then, ecologic damage can be quantified by the amount of leaked oil and the environmental characteristi...

  13. Turbo-generator control with variable valve actuation

    Science.gov (United States)

    Vuk, Carl T [Denver, IA

    2011-02-22

    An internal combustion engine incorporating a turbo-generator and one or more variably activated exhaust valves. The exhaust valves are adapted to variably release exhaust gases from a combustion cylinder during a combustion cycle to an exhaust system. The turbo-generator is adapted to receive exhaust gases from the exhaust system and rotationally harness energy therefrom to produce electrical power. A controller is adapted to command the exhaust valve to variably open in response to a desired output for the turbo-generator.

  14. Microfluidic sieve valves

    Science.gov (United States)

    Quake, Stephen R; Marcus, Joshua S; Hansen, Carl L

    2015-01-13

    Sieve valves for use in microfluidic device are provided. The valves are useful for impeding the flow of particles, such as chromatography beads or cells, in a microfluidic channel while allowing liquid solution to pass through the valve. The valves find particular use in making microfluidic chromatography modules.

  15. Microfluidic Neurons, a New Way in Neuromorphic Engineering?

    Directory of Open Access Journals (Sweden)

    Timothée Levi

    2016-08-01

    Full Text Available This article describes a new way to explore neuromorphic engineering, the biomimetic artificial neuron using microfluidic techniques. This new device could replace silicon neurons and solve the issues of biocompatibility and power consumption. The biological neuron transmits electrical signals based on ion flow through their plasma membrane. Action potentials are propagated along axons and represent the fundamental electrical signals by which information are transmitted from one place to another in the nervous system. Based on this physiological behavior, we propose a microfluidic structure composed of chambers representing the intra and extracellular environments, connected by channels actuated by Quake valves. These channels are equipped with selective ion permeable membranes to mimic the exchange of chemical species found in the biological neuron. A thick polydimethylsiloxane (PDMS membrane is used to create the Quake valve membrane. Integrated electrodes are used to measure the potential difference between the intracellular and extracellular environments: the membrane potential.

  16. Quantitative assessment of an aortic and pulmonary valve function according to valve fenestration

    International Nuclear Information System (INIS)

    Mirkhani, S.H.; Golestani, M.G.; Hosini, M.; Kazemian, A.

    1999-01-01

    There are some reasons for malfunction of aortic and pulmonary valve like fibrosis, calcification, and atheroma. Although, in some papers fenestration were known as a pathologic sign, but it is not generally accepted, while this matter is important in choosing suitable Homograft Heart Valve. In this paper fenestrations and its size, numbers and situation effect was studied. We collected 98 hearts, the donors died because of accident, we excluded valves with atheroma, calcification, fibrosis and unequal cusps, 91 aortic and 93 pulmonary valves were given further consideration. We classified valves according to situation, number and size of fenestration. Each valve was tested with 104 cm of non-nal saline column pressure which is equal to 76 mm Hg. Valve efficacy was detected by fluid flow assay. With study of 184 valves, 95 had no fenestration, 64 had less than 2 fenestration and 25 had more than 2 fenestration. Valve efficacy in condition of less than 2 fenestration was more than others (p <0.01). Malfunction effects of fenestration increased in larger valve and it will be decreased if their situation would be marginal (free margin of cusp). In the comparison of aortic and pulmonary valve we saw that malfunction effect of fenestration in pulmonary valve was more than aortic valve. Our experience in Immam Khomeini Homograft Valve Bank has shown that a great deal of valves is fenestrated. It seems that fenestration must be considered as a quality criterion in homograft valve preparation, especially in pulmonary and large aortic valves; but complementary studies is necessary

  17. Semi-device-independent security of one-way quantum key distribution

    International Nuclear Information System (INIS)

    Pawlowski, Marcin; Brunner, Nicolas

    2011-01-01

    By testing nonlocality, the security of entanglement-based quantum key distribution (QKD) can be enhanced to being ''device-independent.'' Here we ask whether such a strong form of security could also be established for one-way (prepare and measure) QKD. While fully device-independent security is impossible, we show that security can be guaranteed against individual attacks in a semi-device-independent scenario. In the latter, the devices used by the trusted parties are noncharacterized, but the dimensionality of the quantum systems used in the protocol is assumed to be bounded. Our security proof relies on the analogies between one-way QKD, dimension witnesses, and random-access codes.

  18. Modified one-way coupled map lattices as communication cryptosystems

    International Nuclear Information System (INIS)

    Zhao Mingchao; Li Kezan; Fu Xinchu

    2009-01-01

    In this paper, we modify the original communication cryptosystem based on OCML (one-way coupled map lattices), and present a modified OCML communication cryptosystem. The modified OCML communication cryptosystem is shown to have some additional advantages compared to the original one, e.g., it has a larger parameter space, and is more capable of anti-error analysis. And, we apply this modified OCML communication cryptosystem for multiplex OCML communication.

  19. Rotary pneumatic valve

    Science.gov (United States)

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  20. Heavy gas valves

    Energy Technology Data Exchange (ETDEWEB)

    Steier, L [Vereinigte Armaturen Gesellschaft m.b.H., Mannheim (Germany, F.R.)

    1979-01-01

    Heavy gas valves must comply with special requirements. Apart from absolute safety in operation there are stringent requirements for material, sealing and ease of operation even in the most difficult conditions. Ball valves and single plate pipe gate valves lateral sealing rings have a dual, double sided sealing effect according to the GROVE sealing system. Single plate gate valves with lateral protective plates are suitable preferably for highly contaminated media. Soft sealing gate valves made of cast iron are used for low pressure applications.

  1. THE RESULTS OF SURGICAL TREATMENT OF TRICUSPID VALVE INFECTIVE ENDOCARDITIS USING VALVE REPAIR AND VALVE REPLACEMENT OPERATIONS

    Directory of Open Access Journals (Sweden)

    S. A. Kovalev

    2015-01-01

    Full Text Available Aim. To evaluate in-hospital and long-term results of surgical treatment of patients with infective endocarditis of the tricuspid valve, to compare the effectiveness of valve repair and valve replacement techniques, and to identify risk factors of mortality and reoperations. Materials and methods. 31 surgical patients with tricuspid valve infective endocarditis were evaluated. Patients were divided into 2 groups. In Group 1 (n = 14 repairs of the tricuspid valve were performed, in Group 2 (n = 17 patients had undergone tricuspid valve replacements. Epidemiological, clinical, microbiological and echocardiographic data were studied. Methods of comparative analysis, the Kaplan–Meier method, and Cox risk models were applied. Results. The most common complication of in-hospital stay was atrioventricular block (17.7% of cases in Group 2. In Group 1, this type of complication was not found. Hospital mortality was 7.14% in Group 1, and 0% in Group 2. Long-term results have shown the significant reduction of heart failure in general cohort and in both groups. In Group 1 the severity of heart failure in the long term was less than in Group 2. No significant differences in the severity of tricuspid regurgitation were found between the groups. In 7-year follow up no cases of death were registered in Group 1. Cumulative survival rate in Group 2 within 60 months was 67.3 ± 16.2%. No reoperations were performed in patients from Group 1. In Group 2, the freedom from reoperation within 60 months was 70.9 ± 15.3%. Combined intervention was found as predictor of postoperative mortality. Prosthetic valve endocarditis was identified as risk factor for reoperation. Conclusion. Valve repair and valve replacement techniques of surgical treatment of tricuspid valve endocarditis can provide satisfactory hospital and long-term results. Tricuspid valve repair techniques allowed reducing the incidence of postoperative atrioventricular block. In the long-term, patients

  2. Recent improvements in check valve monitoring methods

    International Nuclear Information System (INIS)

    Haynes, H.D.

    1991-01-01

    In support of the NRC Nuclear Plant Aging Research (NPAR) program, ORNL has carried out an evaluation of three check valve monitoring methods: acoustic emission, ultrasonic inspection, and magnetic flux signature analysis (MFSA). This work has focussed on determining the capabilities of each method to provide diagnostic information useful in determining check valve aging and service wear effects (degradation) and undesirable operating modes. In addition, as part of the ORNL Advanced Diagnostic Engineering Research and Development Center (ADEC), two novel nonintrusive monitoring methods were developed (external ac- and dc-magnetic monitoring) that provide several improvements over the other methods. None of the examined methods could, by themselves, monitor the instantaneous position and motion of check valve internals and valve leakage; however, the combination of acoustic emission monitoring with one of the other methods provides the means to determine vital check valve operational information. This paper describes the benefits and limitations associated with each method and includes recent laboratory and field test data to illustrate the capabilities of these methods to detect simulated check valve degradation. 3 refs., 22 figs., 4 tabs

  3. Recent improvements in check valve monitoring methods

    International Nuclear Information System (INIS)

    Haynes, H.D.

    1990-01-01

    In support of the NRC Nuclear Plant Aging Research (NPAR) program, ORNL has carried out an evaluation of three check valve monitoring methods: acoustic emission, ultrasonic inspection, and magnetic flux signature analysis (MFSA). This work has focused on determining the capabilities of each method to provide diagnostic information useful in determining check valve aging and service wear effects (degradation) and undesirable operating modes. In addition, as part of the ORNL Advanced Diagnostic Engineering Research and Development Center (ADEC), two noval nonintrusive monitoring methods were developed (external ac- and dc-magnetic monitoring) that provide several improvements over the other methods. None of the examined methods could, by themselves, monitor the instantaneous position and motion of check valve internals and valve leakage; however, the combination of acoustic emission monitoring with one of the other methods provides the means to determine vital check valve operational information. This paper describes the benefits and limitations associated with each method and includes recent laboratory and field test data to illustrate the capabilities of these methods to detect simulated check valve degradation. 3 refs., 22 figs., 4 tabs

  4. Measurement of one-way velocity of light and light-year

    Science.gov (United States)

    Chen, Shao-Guang

    For space science and astronomy the fundamentality of one-way velocity of light (OWVL) is selfevident. The measurement of OWVL (distance / interval) and the clock synchronization with light-signal transfer make a logical circulation. This means that OWVL could not be directly measured but only come indirectly from astronomical method (Romer's Io eclipse and Bradley's sidereal aberration). Furthermore, the light-year by definitional OWVL and the trigonometry distance with AU are also un-measurable. In this report two methods of clock synchronization to solve this problem were proposed: The arriving-time difference of longitudinal-transverse wave (Ts - Tp) or ordinary-extraordinary light (Te - To) is measured by single clock at one end of a dual-speed transmission-line, the signal transmission-delay (from sending-end time Tx to receiving-end time Tp or To) calculated with wave-speed ratio is: (Tp -Tx) = (Ts -Tp) / ((Vp / Vs) - 1) or: (To -Tx) = (Te - To) / ((Vo / Ve ) - 1), where (Vp / Vs) = (E / k) 1/2 is Yang's / shear elastic-modulus ratio obtained by comparing two strains at same stress, (Vo / Ve) = (ne / no) is extraordinary/ordinary light refractive-index ratio obtained by comparing two deflection-angles. Then, two clocks at transmission-line two ends can be synchronized directly to measure the one-way velocity of light and light-year, which work as one earthquakestation with single clock measures first-shake-time and the distance to epicenter. The readings Na and Nb of two counters Ca and Cb with distance L are transferred into a computer C by two leads with transmission-delay Tac and Tbc respectively. The computer progressing subtraction operation exports steady value: (Nb - Na) = f (Ta - Tb ) + f (Tac - Tbc ), where f is the frequency of light-wave always passing Ca and Cb, Ta and Tb are the count-start time of Ca and Cb respectively. From the transmission-delay possess the spatial translational and rotational invariability, the computer exports steady value

  5. Oil pipeline valve automation for spill reduction

    Energy Technology Data Exchange (ETDEWEB)

    Mohitpour, Mo; Trefanenko, Bill [Enbridge Technology Inc, Calgary (Canada); Tolmasquim, Sueli Tiomno; Kossatz, Helmut [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    Liquid pipeline codes generally stipulate placement of block valves along liquid transmission pipelines such as on each side of major river crossings where environmental hazards could cause or are foreseen to potentially cause serious consequences. Codes, however, do not stipulate any requirement for block valve spacing for low vapour pressure petroleum transportation, nor for remote pipeline valve operations to reduce spills. A review of pipeline codes for valve requirement and spill limitation in high consequence areas is thus presented along with a criteria for an acceptable spill volume that could be caused by pipeline leak/full rupture. A technique for deciding economically and technically effective pipeline block valve automation for remote operation to reduce oil spilled and control of hazards is also provided. In this review, industry practice is highlighted and application of the criteria for maximum permissible oil spill and the technique for deciding valve automation thus developed, as applied to ORSUB pipeline is presented. ORSUB is one of the three initially selected pipelines that have been studied. These pipelines represent about 14% of the total length of petroleum transmission lines operated by PETROBRAS Transporte S.A. (TRANSPETRO) in Brazil. Based on the implementation of valve motorization on these three pipeline, motorization of block valves for remote operation on the remaining pipelines is intended, depending on the success of these implementations, on historical records of failure and appropriate ranking. (author)

  6. Carbon Fiber Reinforced Carbon Composite Valve for an Internal Combustion Engine

    Science.gov (United States)

    Rivers, H. Kevin (Inventor); Ransone, Philip O. (Inventor); Northam, G. Burton (Inventor)

    1999-01-01

    A carbon fiber reinforced carbon composite valve for internal combustion engines and the like formed of continuous carbon fibers throughout the valve's stem and head is disclosed. The valve includes braided carbon fiber material over axially aligned unidirectional carbon fibers forming a valve stem; the braided and unidirectional carbon fibers being broomed out at one end of the valve stem forming the shape of the valve head; the valve-shaped structure being densified and rigidized with a matrix of carbon containing discontinuous carbon fibers: and the finished valve being treated to resist oxidation. Also disclosed is a carbon matrix plug containing continuous and discontinuous carbon fibers and forming a net-shape valve head acting as a mandrel over which the unidirectional and braided carbon fibers are formed according to textile processes. Also disclosed are various preform valves and processes for making finished and preform carbon fiber reinforced carbon composite valves.

  7. Aortic valve replacement for Libman-Sacks endocarditis.

    Science.gov (United States)

    Keenan, Jack B; Janardhanan, Rajesh; Larsen, Brandon T; Khalpey, Zain

    2016-10-04

    A 24-year-old man with systemic lupus erythematosus and antiphospholipid syndrome complicated by lupus nephritis presented with acute limb ischaemia secondary to an embolus. Following embolectomy, the patient underwent a transthoracic echocardiogram which revealed a large vegetation on all three cusps of the aortic valve. The patient was taken for an urgent aortic valve replacement with a mechanical valve. Cultures of one cusp remained sterile. Histopathological examination of the remaining two cusps revealed sterile fibrin-rich thrombotic vegetations characteristic of non-bacterial thrombotic endocarditis. 2016 BMJ Publishing Group Ltd.

  8. Gamma Ray Sterilization of Starr-Edwards Heart Valve Prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Gibbons, J. R. P.; Alladine, M. F. [London Chest Hospital, London (United Kingdom)

    1967-09-15

    Starr-Edwards valves have normally been sterilized by exposure to ethylene oxide or by autoclaving. Patients having a prosthetic valve replacement are known to have a higher incidence of endocarditis in comparison with patients in which no prosthesis has been used. Ethylene oxide will only sterilize the surface of the valve and autoclaving has caused distortion of the polytetrafluorethylene ring. Work has been done on the effect of gamma radiation on the components of these valve prostheses and is given in detail. The bacteriological efficiency, at a total absorbed dose of 2. 5 Mrad, has been established. Thirty valves treated by this method have now been inserted and twelve patients have been examined post-operatively for a period of one to two years. All valves are working normally and there has been no evidence of blood-borne infection or malfunction of the valve. (author)

  9. Magnetically operated check valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-06-01

    A magnetically operated check valve is disclosed. The valve is comprised of a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  10. Methodology for Check Valve Selection to Maintain the Integrity of Pipeline against the Check Valve Slam for the KIJANG Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dayong; Yoon, Hyungi; Seo, Kyoungwoo; Kim, Seonhoon [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The check valve slam results in a water hammer and unexpected system pressure rise in the pipeline. Sometimes, the pressure rise by check valve slam in the pipeline exceeds the design pressure and then it causes the rupture of pipeline. Therefore, check valve slam significantly influences on the integrity of pipe. Especially, this it is most likely to occur by check valve installed in the discharge of pump when one pump trips among the two or more running in parallel pump system. This study focuses on the check valve selection to maintain the integrity of PCS pipeline against the check valve slam. If design head for KJRR PCS pipeline is higher than the sum of static head and 11 m, any type check valves can be installed at the discharge of pump. However, if design head for KJRR PCS pipeline is lower than the sum of static head and 11 m, installation of swing and ball check on the discharge of pump must be avoid to prevent the rupture of PCS pipeline.

  11. Methodology for Check Valve Selection to Maintain the Integrity of Pipeline against the Check Valve Slam for the KIJANG Research Reactor

    International Nuclear Information System (INIS)

    Kim, Dayong; Yoon, Hyungi; Seo, Kyoungwoo; Kim, Seonhoon

    2016-01-01

    The check valve slam results in a water hammer and unexpected system pressure rise in the pipeline. Sometimes, the pressure rise by check valve slam in the pipeline exceeds the design pressure and then it causes the rupture of pipeline. Therefore, check valve slam significantly influences on the integrity of pipe. Especially, this it is most likely to occur by check valve installed in the discharge of pump when one pump trips among the two or more running in parallel pump system. This study focuses on the check valve selection to maintain the integrity of PCS pipeline against the check valve slam. If design head for KJRR PCS pipeline is higher than the sum of static head and 11 m, any type check valves can be installed at the discharge of pump. However, if design head for KJRR PCS pipeline is lower than the sum of static head and 11 m, installation of swing and ball check on the discharge of pump must be avoid to prevent the rupture of PCS pipeline

  12. Hardfacing and packings for improved valve performance

    International Nuclear Information System (INIS)

    Aikin, J.A.; Patrick, J.N.F.; Inglis, I.

    2003-01-01

    The CANDU Owners Group (COG), Chemistry, Materials and Components (CMC) Program has supported an ongoing program on valve maintenance and performance for several years. An overview is presented of recent work on iron-based hardfacing, packing qualification, friction testing of polytetrafluoroethylene (PTFE) packings, and an investigation of re-torquing valve packing. Based on this program, two new valve-packing materials have been qualified for use in CANDU stations. By doing this, CANDU maintenance can avoid having only one packing qualified for station use, as well as assess the potential impact of the industry trend towards using lower gland loads. The results from corrosion tests by AECL and the coefficient of friction studies at Battelle' s tribology testing facilities on Delcrome 910, an iron-based hardfacing alloy, indicate it is an acceptable replacement for Stellite 6 under certain conditions. This information can be used to update in-line valve purchasing specifications. The renewed interest in friction characteristics, and environmental qualification (EQ) of packing containing PTFE has resulted in a new test program in these areas. The COG-funded valve programs have resulted in modifications to design specifications for nuclear station in-line valves and have led to better maintenance practices and valve reliability. In the end, this means lower costs and cheaper electricity. (author)

  13. [Mitral valve endocarditis after Turkish "Festival of Sacrifice"].

    Science.gov (United States)

    Blaich, A; Fasel, D; Kaech, C; Frei, R

    2011-09-01

    Erysipelothrix rhusiopathiae is the causative agent of swine erysipelas. Systemic infections caused by E. rhusiopathiae are rare, but often (90%) associated with endocarditis. In about 60% of cases endocarditis develops on normal heart valves, and despite appropriate antibiotic therapy about one-third of the patients requires valve replacement. We report the case of a housewife, who developed a mitral valve endocarditis due to E. rhusiopathiae after preparing meat for the Turkish "Festival of Sacrifice".

  14. One-way Ponderomotive Barrier in a Uniform Magnetic Field

    International Nuclear Information System (INIS)

    Dodin, I.Y.; Fisch, N.J.

    2005-01-01

    The possibility of an asymmetric ponderomotive barrier in a nonuniform dc magnetic field by high-frequency radiation near the cyclotron resonance for selected plasma species was contemplated in Physics of Plasmas 11 (November 2004) 5046-5064. Here we show that a similar one-way barrier, which reflects particles incident from one side while transmitting those incident from the opposite side, can be produced also in a uniform magnetic field, entirely due to inhomogeneity of high-frequency drive

  15. Training and certification in endobronchial ultrasound-guided transbronchial needle aspiration

    Science.gov (United States)

    Konge, Lars; Nayahangan, Leizl Joy; Clementsen, Paul Frost

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) plays a key role in the staging of lung cancer, which is crucial for allocation to surgical treatment. EBUS-TBNA is a complicated procedure and simulation-based training is helpful in the first part of the long learning curve prior to performing the procedure on actual patients. New trainees should follow a structured training programme consisting of training on simulators to proficiency as assessed with a validated test followed by supervised practice on patients. The simulation-based training is superior to the traditional apprenticeship model and is recommended in the newest guidelines. EBUS-TBNA and oesophageal ultrasound-guided fine needle aspiration (EUS-FNA or EUS-B-FNA) are complementary to each other and the combined techniques are superior to either technique alone. It is logical to learn and to perform the two techniques in combination, however, for lung cancer staging solely EBUS-TBNA simulators exist, but hopefully in the future simulation-based training in EUS will be possible. PMID:28840013

  16. Infective Endocarditis of the Aortic Valve with Anterior Mitral Valve Leaflet Aneurysm

    NARCIS (Netherlands)

    Tomsic, Anton; Li, Wilson W. L.; van Paridon, Marieke; Bindraban, Navin R.; de Mol, Bas A. J. M.

    2016-01-01

    Mitral valve leaflet aneurysm is a rare and potentially devastating complication of aortic valve endocarditis. We report the case of a 48-year-old man who had endocarditis of the native aortic valve and a concomitant aneurysm of the anterior mitral valve leaflet. Severe mitral regurgitation occurred

  17. Bentall Procedure Using Cryopreserved Valved Aortic Homografts

    Science.gov (United States)

    Christenson, Jan T.; Sierra, Jorge; Trindade, Pedro T.; Didier, Dominique; Kalangos, Afksendiyos

    2004-01-01

    The Bentall procedure is the standard operation for patients who have lesions of the ascending aorta associated with aortic valve disease. In many cases, however, mechanical prosthetic conduits are not suitable. There are few reports in the English-language medical literature concerning the mid- to long-term outcome of Bentall operations with cryopreserved homografts. Therefore, we reviewed our experience with this procedure and valved homografts. From January 1997 through December 2002, 21 patients underwent a Bentall operation with cryopreserved homografts at our institution. There were 14 males and 7 females; the mean age was 36 ± 21 years (range, 15–74 years). Eleven patients had undergone previous aortic valve surgery. All patients had aortic dilatation or aneurysms involving the ascending aorta. Indications for surgery included aortic valve stenosis or insufficiency, and aortic valve endocarditis (native valve or prosthetic). One patient had Takayasu's arteritis and 3 had Marfan syndrome. There was 1 hospital death (due to sepsis), but no other major postoperative complications. The mean hospital stay was 14 ± 7 days. Follow-up echocardiographic and computed tomographic scans were performed yearly. The mean follow-up was 34 months (6–72 months). Follow-up imaging revealed no calcifications or degenerative processes related to the homograft. Four patients had minimal valve regurgitation. Two patients died during follow-up. The 3-year actuarial survival rate was 85.7%. Our data suggest that the Bentall procedure with a valved homograft conduit is a safe procedure with excellent mid- to long-term results, comparable to results reported with aortic valve replacement with a homograft. PMID:15745290

  18. Mechanism study of freeze-valve for molten salt reactor (MSR)

    International Nuclear Information System (INIS)

    Qinhua, Zhang

    2014-01-01

    Molten salt reactor (MSR) is one of the fourth generation nuclear reactor, ordinary nuclear grade valve is unsuitable for MSR due to its special coolant and extraordinary working temperature. Freeze-valve is proposed as the most appropriate valve for MSR, but the technology issue about freeze-valve has not been report in recent decades. Its significance to test the comprehensive property of freeze-valve for the application in MSR. A high temperature molten salt test loop was built which the physics property of salt is similar to the coolant of MSR. The results indicate that freeze-valve has a good performance use in the molten salt circumstances of high temperature (max 700 deg. C) and strong corrosion (authors)

  19. Aortic valve insufficiency in the teenager and young adult: the role of prosthetic valve replacement.

    Science.gov (United States)

    Bradley, Scott M

    2013-10-01

    The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.

  20. Development of multilayer piezoelectric actuator valve for JT-60

    International Nuclear Information System (INIS)

    Miyo, Yasuhiko; Hiratsuka, Hajime; Masui, Hiroshi; Hosogane, Nobuyuki; Miya, Naoyuki

    2001-11-01

    In order to improve the gas injection valve used for the operation of JT-60, a new type of valve (multilayer piezoelectric actuator valve) was developed. The conventional valve (bimorph piezoelectric valve) has been used for 15 years since the beginning of experimental operation in April, 1985. However, it came to be hard to keep the performance of the valve because of the deterioration of the driving source, i.e. piezoelectric element. Developments of the new valve were carried out based on experiences through experimental operations in JT-60. Requirements for the design are: (1) to be hard structure for making a sheet leak, (2) to allow a repair work at atmosphere side without an air vent of the vacuum vessel, (3) to be more smaller and lighter compared with the conventional one, and (4) to have a high maintenance efficiency by utilizing of the commercial piezoelectric elements and power supplies. The newly developed valve was examined with various tests such as gas flow characteristic test, high magnetic field proof test, high temperature proof test and gas flow rate test for aged deterioration. Results, confirm that the performance of the valve is applicable for JT-60 operations. (author)

  1. Controllable valve in a nuclear reactor system

    International Nuclear Information System (INIS)

    Schabert, H.P.; Laurer, E.

    1980-01-01

    The quick-acting gate valve of the PWR is opened and closed by means of two pistons and live steam. One of the pistons is connected to the valve disk by a piston rod which is concentrically lead into another hollow piston rod being connected to the second piston. Stops limit the strokes of the two pistons. (GL) [de

  2. A review of design and modeling of magnetorheological valve

    Science.gov (United States)

    Abd Fatah, Abdul Yasser; Mazlan, Saiful Amri; Koga, Tsuyoshi; Zamzuri, Hairi; Zeinali, Mohammadjavad; Imaduddin, Fitrian

    2015-01-01

    Following recent rapid development of researches in utilizing Magnetorheological (MR) fluid, a smart material that can be magnetically controlled to change its apparent viscosity instantaneously, a lot of applications have been established to exploit the benefits and advantages of using the MR fluid. One of the most important applications for MR fluid in devices is the MR valve, where it uses the popular flow or valve mode among the available working modes for MR fluid. As such, MR valve is widely applied in a lot of hydraulic actuation and vibration reduction devices, among them are dampers, actuators and shock absorbers. This paper presents a review on MR valve, discusses on several design configurations and the mathematical modeling for the MR valve. Therefore, this review paper classifies the MR valve based on the coil configuration and geometrical arrangement of the valve, and focusing on four different mathematical models for MR valve: Bingham plastic, Herschel-Bulkley, bi-viscous and Herschel-Bulkley with pre-yield viscosity (HBPV) models for calculating yield stress and pressure drop in the MR valve. Design challenges and opportunities for application of MR fluid and MR valve are also highlighted in this review. Hopefully, this review paper can provide basic knowledge on design and modeling of MR valve, complementing other reviews on MR fluid, its applications and technologies.

  3. Thermal stability of low dose Ga+ ion irradiated spin valves

    International Nuclear Information System (INIS)

    Qi Xianjin; Wang Yingang; Zhou Guanghong; Li Ziquan

    2009-01-01

    The thermal stability of low dose Ga + ion irradiated spin valves has been investigated and compared with that of the as-prepared ones. The dependences of exchange field, measured using vibrating sample magnetometer at room temperature, on magnetic field sweep rate and time spent at negative saturation of the pinned ferromagnetic layer, and training effect were explored. The training effect is observed on both the irradiated spin valves and the as-prepared ones. The magnetic field sweep rate dependence of the exchange bias field of the irradiated spin valves is nearly the same as that of the as-prepared ones. For the as-prepared structure thermal activation has been observed, which showed that holding the irradiated structure at negative saturation of the pinned ferromagnetic layer for up to 28 hours results in no change in the exchange field. The results indicate that the thermal stability of the ion irradiated spin valves is the same as or even better than the as-prepared ones.

  4. Design and performance characteristic analysis of servo valve-type water hydraulic poppet valve

    International Nuclear Information System (INIS)

    Park, Sung Hwan

    2009-01-01

    For water hydraulic system control, the flow or pressure control using high-speed solenoid valve controlled by PWM control method could be a good solution for prevention of internal leakage. However, since the PWM control of on-off valves cause extensive flow and pressure fluctuation, it is difficult to control the water hydraulic actuators precisely. In this study, the servo valve-type water hydraulic valve using proportional poppet as the main valve is designed and the performance characteristics of the servo valve-type water hydraulic valve are analyzed. Furthermore, it is demonstrated through experiments that a decline in control chamber pressure that follows the change of pilot flow is caused by the occurrence of cavitation around the proportional poppet, and that fundamental characteristics of the developed valve remain unaffected by the occurrence of cavitation

  5. Check valve diagnostics utilizing acoustic and magnetic technologies

    International Nuclear Information System (INIS)

    Agostinelli, A.

    1991-01-01

    The potential hazards associated with check valve failures make it necessary to detect check valve problems before they cause significant damage. In the nuclear industry, check valve failures are known to have resulted in damaging water hammer conditions, overpressurization of low pressure systems, steam binding of auxiliary feedwater pumps, and other serious component damage in power plant environments. Similar problems exist in fossil power and various process industries, but the resources dedicated to valve maintenance issues are greatly reduced. However, the trend toward plant life extension, predictive maintenance, and maximum operating efficiency will raise the general awareness of check valve maintenance in commercial (non-nuclear) applications. Although this paper includes specific references to the nuclear industry, the check valve problem conditions and diagnostic techniques apply across all power and process plant environments. The ability to accurately diagnose check valve conditions using non-intrusive, predictive maintenance testing methods allows for a more cost-efficient, productive maintenance program. One particular diagnostic system, called Quickcheck trademark, assists utilities in addressing these concerns. This article presents actual field test data and analysis that demonstrate the power of check valve diagnostics. Prior to presenting the field data, a brief overview of the system is overviewed

  6. Integral isolation valve systems for loss of coolant accident protection

    Science.gov (United States)

    Kanuch, David J.; DiFilipo, Paul P.

    2018-03-20

    A nuclear reactor includes a nuclear reactor core comprising fissile material disposed in a reactor pressure vessel having vessel penetrations that exclusively carry flow into the nuclear reactor and at least one vessel penetration that carries flow out of the nuclear reactor. An integral isolation valve (IIV) system includes passive IIVs each comprising a check valve built into a forged flange and not including an actuator, and one or more active IIVs each comprising an active valve built into a forged flange and including an actuator. Each vessel penetration exclusively carrying flow into the nuclear reactor is protected by a passive IIV whose forged flange is directly connected to the vessel penetration. Each vessel penetration carrying flow out of the nuclear reactor is protected by an active IIV whose forged flange is directly connected to the vessel penetration. Each active valve may be a normally closed valve.

  7. Which valve is which?

    Directory of Open Access Journals (Sweden)

    Pravin Saxena

    2015-01-01

    Full Text Available A 25-year-old man presented with a history of breathlessness for the past 2 years. He had a history of operation for Tetralogy of Fallot at the age of 5 years and history suggestive of Rheumatic fever at the age of 7 years. On echocardiographic examination, all his heart valves were severely regurgitating. Morphologically, all the valves were irreparable. The ejection fraction was 35%. He underwent quadruple valve replacement. The aortic and mitral valves were replaced by metallic valve and the tricuspid and pulmonary by tissue valve.

  8. High readmission rate after heart valve surgery

    DEFF Research Database (Denmark)

    Sibilitz, K L; Berg, S K; Thygesen, L C

    2015-01-01

    investigated. RESULTS: After valve surgery, the self-reported health was lower (Short Form-36 (SF-36) Physical Component Scale (PCS): 44.5 vs. 50.6 and Mental Component Scale (MCS): 51.9 vs. 55.0, pClinical signs......BACKGROUND: After heart valve surgery, knowledge on long-term self-reported health status and readmission is lacking. Thus, the optimal strategy for out-patient management after surgery remains unclear. METHODS: Using a nationwide survey with linkage to Danish registers with one year follow-up, we...... included all adults 6-12months after heart valve surgery irrespective of valve procedure, during Jan-June 2011 (n=867). Participants completed a questionnaire regarding health-status (n=742), and answers were compared with age- and sex-matched healthy controls. Readmission rates and mortality were...

  9. Analysis of failure and maintenance experiences of motor operated valves in a Finnish nuclear power plant

    International Nuclear Information System (INIS)

    Simola, K.; Laakso, K.

    1992-01-01

    Operating experiences from 1981 up to 1989 of totally 104 motor operated closing valves (MOV) in different safety systems at TVO I and II nuclear power units were analysed in a systematic way. The qualitative methods used were failure mode and effects analysis (FMEA) and maintenance effects and criticality analysis (MECA). The failure descriptions were obtained from power plant's computerized failure reporting system. The reported 181 failure events were reanalysed and sorted according to specific classifications developed for the MOV function. Filled FMEA and MECA sheets on individual valves were stored in a microcomputer data base for further analyses. Analyses were performed for the failed mechanical and electrical valve parts, ways of detection of failure modes, failure effects, and repair and unavailability times

  10. Fluid-structure interaction dynamic simulation of spring-loaded pressure relief valves under seismic wave

    Science.gov (United States)

    Lv, Dongwei; Zhang, Jian; Yu, Xinhai

    2018-05-01

    In this paper, a fluid-structure interaction dynamic simulation method of spring-loaded pressure relief valve was established. The dynamic performances of the fluid regions and the stress and strain of the structure regions were calculated at the same time by accurately setting up the contact pairs between the solid parts and the coupling surfaces between the fluid regions and the structure regions. A two way fluid-structure interaction dynamic simulation of a simplified pressure relief valve model was carried out. The influence of vertical sinusoidal seismic waves on the performance of the pressure relief valve was preliminarily investigated by loading sine waves. Under vertical seismic waves, the pressure relief valve will flutter, and the reseating pressure was affected by the amplitude and frequency of the seismic waves. This simulation method of the pressure relief valve under vertical seismic waves can provide effective means for investigating the seismic performances of the valves, and make up for the shortcomings of the experiment.

  11. [Aortic valve-sparing root reconstruction in Marfan syndrome].

    Science.gov (United States)

    Ogino, H; Sasaki, H; Hanafusa, Y; Hirata, M; Numata, S; Ando, M; Yagihara, T; Kitamura, S

    2002-07-01

    The outcome of aortic valve-sparing root reconstruction in Marfan syndrome was reviewed. Thirteen patients with Marfan syndrome underwent aortic valve-sparing root reconstruction for annuloaortic ectasia or aortic root dissection between 1994 and 1999. The grade of preoperative aortic regurgitation was I in 4, II in 2, III in 5, IV in 2 patients. The procedures of aortic valve-sparing were reimplantation in 7 and remodeling in 5 patients. There was no hospital and late death. Recurrence of aortic regurgitation greater than moderate grade developed in 1 patient immediately after the surgery and in the other 4 patients in the late stage. One patient of them required aortic valve replacement for it. Aortic valve-sparing root reconstruction is applicable in Marfan patients, although the indication should be cautious. Close observation is needed for recurrence of aortic regurgitation.

  12. Anterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Vidyadhar P. Mali

    2006-07-01

    Full Text Available We studied the clinical presentation and management of four patients with anterior urethral valves; a rare cause of urethral obstruction in male children. One patient presented antenatally with oligohydramnios, bilateral hydronephrosis and bladder thickening suggestive of an infravesical obstruction. Two other patients presented postnatally at 1 and 2 years of age, respectively, with poor stream of urine since birth. The fourth patient presented at 9 years with frequency and dysuria. Diagnosis was established on either micturating cystourethrogram (MCU (in 2 or on cystoscopy (in 2. All patients had cystoscopic ablation of the valves. One patient developed a postablation stricture that was resected with an end-to-end urethroplasty. He had an associated bilateral vesicoureteric junction (VUJ obstruction for which a bilateral ureteric reimplantation was done at the same time. On long-term follow-up, all patients demonstrated a good stream of urine. The renal function is normal. Patients are continent and free of urinary infections. Anterior urethral valves are rare obstructive lesions in male children. The degree of obstruction is variable, and so they may present with mild micturition difficulty or severe obstruction with hydroureteronephrosis and renal impairment. Hence, it is important to evaluate the anterior urethra in any male child with suspected infravesical obstruction. The diagnosis is established by MCU or cystoscopy and the treatment is always surgical, either a transurethral ablation or an open resection. The long-term prognosis is good.

  13. Impact of patient-prosthesis mismatch after transcatheter aortic valve-in-valve implantation in degenerated bioprostheses.

    Science.gov (United States)

    Seiffert, Moritz; Conradi, Lenard; Baldus, Stephan; Knap, Malgorzata; Schirmer, Johannes; Franzen, Olaf; Koschyk, Dietmar; Meinertz, Thomas; Reichenspurner, Hermann; Treede, Hendrik

    2012-03-01

    Transcatheter valve-in-valve implantation is evolving as an alternative to reoperative valve replacement in high-risk patients with degenerated bioprostheses. Nevertheless, hemodynamic performance is limited by the previously implanted xenograft. We report our experience with patient-prosthesis mismatch (PPM) after valve-in-valve implantation in the aortic position. Eleven patients (aged 79.3 ± 6.1 years) received transapical implantation of a balloon-expandable pericardial heart valve into a degenerated bioprosthesis (size, 23.9 ± 1.6 mm; range, 21-27 mm) in the aortic position. All patients were considered high risk for surgical valve replacement (logistic European System for Cardiac Operative Risk Evaluation, 31.8% ± 24.1%). Severe PPM was defined as an indexed effective orifice area less than 0.65 cm(2)/m(2), determined by discharge echocardiography. Severe PPM was evident in 5 patients (group 1) and absent in 6 patients (group 2). Mean transvalvular gradients decreased from 29.2 ± 15.4 mm Hg before implantation to 21.2 ± 9.7 mm Hg at discharge (group 1) and from 28.2 ± 9.0 mm Hg before implantation to 15.2 ± 6.5 mm Hg at discharge (group 2). Indexed effective orifice area increased from 0.5 ± 0.1 cm(2)/m(2) to 0.6 ± 0.1 cm(2)/m(2) and from 0.6 ± 0.3 cm(2)/m(2) to 0.8 ± 0.3 cm(2)/m(2). Aortic regurgitation decreased from grade 2.0 ± 1.1 to 0.4 ± 0.5 overall. No differences in New York Heart Association class improvement or survival during follow-up were observed. One patient required reoperation for symptomatic PPM 426 days after implantation. Valve-in-valve implantation can be performed in high-risk surgical patients to avoid reoperation. However, PPM frequently occurs, making adequate patient selection crucial. Small bioprostheses (body surface area less than 1.8 m(2). Larger prostheses seem to carry a lower risk for PPM. Although no delay in clinical improvement was seen at short-term, 1 PPM-related surgical intervention raises concern regarding

  14. Floppy mitral valve (FMV)/mitral valve prolapse (MVP) and the FMV/MVP syndrome: pathophysiologic mechanisms and pathogenesis of symptoms.

    Science.gov (United States)

    Boudoulas, Konstantinos Dean; Boudoulas, Harisios

    2013-01-01

    Mitral valve prolapse (MVP) results from the systolic movement of a portion or segments of the mitral valve leaflets into the left atrium during left ventricular systole. It is well appreciated today that floppy mitral valve (FMV) is the central issue in the MVP and mitral valve regurgitation (MVR) story. The term FMV refers to the expansion of the area of the mitral valve leaflets with elongated chordae tendineae, chordae rupture and mitral annular dilation. FMV/MVP occurs in a heterogeneous group of patients with a wide spectrum of mitral valve involvement from mild to severe. Two types of symptoms can be defined in FMV/MVP patients. In one group of patients, symptoms are directly related to progressive MVR. In the other group, symptoms cannot be explained by the degree of MVR alone; activation of the autonomic nervous system has been implicated for the explanation of symptoms in this group of patients which is referred to as the FMV/MVP syndrome. In this brief review, the natural history, pathophysiologic mechanisms and management of patients with FMV/MVP/MVR and FMV/MVP syndrome are discussed. © 2013 S. Karger AG, Basel.

  15. Fiber heart valve prosthesis: influence of the fabric construction parameters on the valve fatigue performances.

    Science.gov (United States)

    Vaesken, Antoine; Heim, Frederic; Chakfe, Nabil

    2014-12-01

    Transcatheter aortic valve replacement (TAVR) has become today a largely considered alternative technique to surgical valve replacement in patients who are not operable or patients with high risk for open chest surgery. However, the biological valve tissue used in the devices implanted clinically appears to be fragile material when folded for low diameter catheter insertion purpose and released in calcified environment with irregular geometry. Textile polyester material is characterized by outstanding folding and strength properties combined with proven biocompatibility. It could thereof be considered to replace biological valve leaflets in the TAVR procedure. The textile construction parameters must however be tuned to obtain a material compatible with the valve requested durability. In that context, one issue to be addressed is the friction effect that occurs between filaments and between yarns within a fabric under flexure loading. This phenomenon could be critical for the resistance of the material on the long term. The purpose of the present work is to assess the fatigue performances of textile valve prototypes made from different fabric constructions (monofilament, multifilament, calendered mutifilament) under accelerated cyclic loading. The goal is to identify, which construction is the best suited to long term fatigue stress. Results show that calendered multifilament and monofilament fabric constructions undergo strong ruptures already from 40 Mio cycles, while non calendered multifilament appears more durable. The rupture patterns observed point out that durability is directly related to the flexure stiffness level of the fibrous elements in the construction. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Complications and 2-year valve survival following Ahmed valve implantation during the first 2 years of life.

    Science.gov (United States)

    Almobarak, F; Al-Mobarak, F; Khan, A O

    2009-06-01

    To report complications and 2-year valve survival following Ahmed valve implantation during the first 2 years of life. Retrospective institutional case series. Forty-two eyes of 36 patients with Ahmed valve implantation (without prior drainage device surgery) during the first 2 years of life and 2 years' postsurgical follow-up were identified. Most eyes had primary congenital glaucoma (28/42, 66.7%), aphakic glaucoma (5/42, 11.9%) or Peters anomaly (5/42, 11.9%). All but three eyes had prior ocular surgery. Surgery was at a mean age of 11.83 months (m) (SD 5.63). The most common significant postoperative complications were tube malpositioning requiring intervention (11/42, 26.2%), endophthalmitis (3/42, 7.1%; one with tube exposure) and retinal detachment (3/42, 7.1%). Thirty-six eyes (85.8%) required resumption of antiglaucoma medications to maintain intraocular pressure (IOP) valve survival (IOPendophthalmitis and retinal detachment are known potential complications following any incisional surgery for advanced buphthalmos; however, tube exposure is a unique potential problem following aqueous shunt implantation that can lead to intraocular infection. Cumulative valve survival 2 years following implantation was 63.3%.

  17. Environmental qualification testing of TFE valve components

    International Nuclear Information System (INIS)

    Eyvindson, A.; Krasinski, W.; McCutcheon, R.

    1997-01-01

    Valves containing tetrafluoroethylene (TFE) components are being used in many CANDU Nuclear Generating Stations. However, some concerns remain about the performance of TFE after exposure to high levels of radiation. Stations must therefore ensure that such valves perform reliably after being exposed to postulated accident radiation dose levels. The current Ontario Hydro Environmental Qualification [EQ] program specifies much higher postulated radiation exposure than the original design, to account for conditions following a LOCA. Initial assessments indicated that Teflon components would require replacement. Proof of acceptable performance can remove the need for large scale replacement, avoiding a significant cost penalty and preserving benefits due to the superior performance of TFE-based seals. A test program was undertaken at Chalk River Laboratories (CRL) to investigate the performance of three valves after irradiation to 10 Mrad. Such valves are currently used at the Bruce B Nuclear Generating Station. Each contains TFE packing rings; one also has TFE seats. Two of the valves are used in the ECIS recovery system, while the third is used for instrumentation loop isolation or as drain valves. All are exposed to little or no radiation during normal use. Based on the results of the tests, all the valves tested will still meet functional and performance requirements after the TFE components have been exposed to 10 Mrad of irradiation. (author)

  18. Prosthetic valve endocarditis after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; De Backer, Ole; Thyregod, Hans G H

    2015-01-01

    BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an advancing mode of treatment for inoperable or high-risk patients with aortic stenosis. Prosthetic valve endocarditis (PVE) after TAVI is a serious complication, but only limited data exist on its incidence, outcome, and procedural......%) were treated conservatively and 1 with surgery. Four patients (22%) died from endocarditis or complications to treatment, 2 of those (11%) during initial hospitalization for PVE. An increased risk of TAVI-PVE was seen in patients with low implanted valve position (hazard ratio, 2.8 [1.1-7.2]), moderate...

  19. Valve monitoring ITI-MOVATS

    International Nuclear Information System (INIS)

    Moureau, S.

    1993-01-01

    ITI-MOVATS provides a wide range of test devices to monitor the performance of valves: motor operated gate or globe valve, butterfly valve, air operated valve, and check valve. The ITI-MOVATS testing equipment is used in the following three areas: actuator setup/baseline testing, periodic/post-maintenance testing, and differential pressure testing. The parameters typically measured with the MOVATS diagnostic system as well as the devices used to measure them are described. (Z.S.)

  20. The nordic aortic valve intervention (NOTION) trial comparing transcatheter versus surgical valve implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Søndergaard, Lars; Ihlemann, Nikolaj

    2013-01-01

    Degenerative aortic valve (AV) stenosis is the most prevalent heart valve disease in the western world. Surgical aortic valve replacement (SAVR) has until recently been the standard of treatment for patients with severe AV stenosis. Whether transcatheter aortic valve implantation (TAVI) can...

  1. Gasoline New Timing and Flux Adjustable Rotary Valve Design (Hereinafter: Rotary Valve

    Directory of Open Access Journals (Sweden)

    Du huiqi

    2016-01-01

    Full Text Available Conventional gasoline engine with an umbrella valve control cylinder intake and exhaust, in order to achieve sealing effect, the valve is driven by the spring force; at the same time, when the cam opens the valve to overcome the spring force acting. Sealing the better, the more power consumed in the engine mechanical losses, the valve mechanism consumes about 30%, which is not a small loss! This article describes a new type of rotary valve is to significantly reduce mechanical losses, so as to achieve energy saving purposes.

  2. Floppy Mitral Valve (FMV) - Mitral Valve Prolapse (MVP) - Mitral Valvular Regurgitation and FMV/MVP Syndrome.

    Science.gov (United States)

    Boudoulas, Konstantinos Dean; Pitsis, Antonios A; Boudoulas, Harisios

    2016-01-01

    Mitral valve prolapse (MVP) results from the systolic movement of a portion(s) or segment(s) of the mitral valve leaflet(s) into the left atrium during left ventricular (LV) systole. It should be emphasised that MVP alone, as defined by imaging techniques, may comprise a non-specific finding because it also depends on the LV volume, myocardial contractility and other LV hemodynamics. Thus, a floppy mitral valve (FMV) should be the basis for the diagnosis of MVP. Two types of symptoms may be defined in these patients. In one group, symptoms are directly related to progressive mitral regurgitation and its complications. In the other group, symptoms cannot be explained only by the degree of mitral regurgitation alone; neuroendocrine dysfunction has been implicated for the explanation of symptoms in this group of patients that today is referred as the FMV/MVP syndrome. When significant mitral regurgitation is present in a patient with FMV/MVP, surgical intervention is recommended. In patients with a prohibitive risk for surgery, transcatheter mitral valve repair using a mitraclip device may be considered. Furthermore, transcatheter mitral valve replacement may represent an option in the near future as clinical trials are underway. In this brief review, the current concepts related to FMV/MVP and FMV/MVP syndrome will be discussed. Copyright © 2016 Hellenic Cardiological Society. Published by Elsevier B.V. All rights reserved.

  3. Fluid control valves

    International Nuclear Information System (INIS)

    Rankin, J.

    1980-01-01

    A fluid control valve is described in which it is not necessary to insert a hand or a tool into the housing to remove the valve seat. Such a valve is particularly suitable for the control of radioactive fluids since maintenance by remote control is possible. (UK)

  4. What Is Heart Valve Surgery?

    Science.gov (United States)

    ... working correctly. Most valve replacements involve the aortic Tricuspid valve and mitral valves. The aortic valve separates ... where it shouldn’t. This is called incompetence, insufficiency or regurgitation. • Prolapse — mitral valve flaps don’t ...

  5. What Is Heart Valve Disease?

    Science.gov (United States)

    ... and replacing it with a man-made or biological valve. Biological valves are made from pig, cow, or human ... the valve. Man-made valves last longer than biological valves and usually don’t have to be ...

  6. Relief valve testing study

    International Nuclear Information System (INIS)

    BROMM, R.D.

    2001-01-01

    Reclosing pressure-actuated valves, commonly called relief valves, are designed to relieve system pressure once it reaches the set point of the valve. They generally operate either proportional to the differential between their set pressure and the system pressure (gradual lift) or by rapidly opening fully when the set pressure is reached (pop action). A pop action valve allows the maximum fluid flow through the valve when the set pressure is reached. A gradual lift valve allows fluid flow in proportion to how much the system pressure has exceeded the set pressure of the valve (in the case of pressure relief) or has decreased below the set pressure (vacuum relief). These valves are used to protect systems from over and under pressurization. They are used on boilers, pressure vessels, piping systems and vacuum systems to prevent catastrophic failures of these systems, which can happen if they are under or over pressurized beyond the material tolerances. The construction of these valves ranges from extreme precision of less than a psi tolerance and a very short lifetime to extremely robust construction such as those used on historic railroad steam engines that are designed operate many times a day without changing their set pressure when the engines are operating. Relief valves can be designed to be immune to the effects of back pressure or to be vulnerable to it. Which type of valve to use depends upon the design requirements of the system

  7. Comparative study between CardiaMed valves (freely floating valve leaflets versus St. Jude Medical (fixed valve leaflets in mitral valve replacement surgery

    Directory of Open Access Journals (Sweden)

    Mostafa Ahmed

    2017-09-01

    Conclusions: CardiaMed freely floating leaflet prostheses showed good hemodynamic characteristics. The prosthesis adequately corrects hemodynamics and is safe and no worse than the St. Jude Medical valve in the mitral valve position.

  8. Face-Sealing Butterfly Valve

    Science.gov (United States)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  9. Transapical JenaValve in a patient with mechanical mitral valve prosthesis.

    LENUS (Irish Health Repository)

    O' Sullivan, Katie E

    2014-01-29

    We report the first case of transcatheter aortic valve replacement implantation using JenaValve™ in a patient with mechanical mitral valve prosthesis. We believe that the design features of this valve may be particularly suited for use in this setting. © 2014 Wiley Periodicals, Inc.

  10. Butterfly valves for seawater

    International Nuclear Information System (INIS)

    Yamanaka, Katsuto

    1991-01-01

    Recently in thermal and nuclear power stations and chemical plants which have become large capacity, large quantity of cooling water is required, and mostly seawater is utilized. In these cooling water systems, considering thermal efficiency and economy, the pipings become complex, and various control functions are demanded. For the purpose, the installation of shut-off valves and control valves for pipings is necessary. The various types of valves have been employed, and in particular, butterfly valves have many merits in their function, size, structure, operation, maintenance, usable period, price and so on. The corrosion behavior of seawater is complicated due to the pollution of seawater, therefore, the environment of the valves used for seawater became severe. The structure and the features of the butterfly valves for seawater, the change of the structure of the butterfly valves for seawater and the checkup of the butterfly valves for seawater are reported. The corrosion of metallic materials is complicatedly different due to the locating condition of plants, the state of pipings and the condition of use. The corrosion countermeasures for butterfly valves must be examined from the synthetic viewpoints. (K.I.)

  11. Supra-annular valve strategy for an early degenerated transcatheter balloon-expandable heart valve.

    Science.gov (United States)

    Kamioka, Norihiko; Caughron, Hope; Corrigan, Frank; Block, Peter; Babaliaros, Vasilis

    2018-01-23

    Currently, there are no recommendations regarding the selection of valve type for a transcatheter heart valve (THV)-in-THV procedure. A supra-annular valve design may be superior in that it results in a larger effective orifice area and may have a lower chance of valve thrombosis after THV-in-THV. In this report, we describe the use of a supra-annular valve strategy for an early degenerated THV. © 2018 Wiley Periodicals, Inc.

  12. The effect of valve strategy on in-cylinder flow and combustion

    Energy Technology Data Exchange (ETDEWEB)

    Soederberg, F

    1997-01-01

    This paper examines the effects of different valve strategies and their effect on in-cylinder flow and combustion. A conventional four valve per cylinder otto engine was modified to enable optical access. The flow measurements were made with a two-component laser Doppler velocimetry system. The combustion was monitored by running pressure data from a pressure transducer through a one-zone heat release model. The results show that when the valves operate normally a barrel flow is present and when one valve is closed a swirling flow occurs. No increase in turbulence was found with later phasing, except in the case of very late inlet valve opening and port deactivation. This resulted in a jet with high turbulence, making the combustion fast and stable, even with a very lean mixture ({lambda}=1.8). 6 refs, 44 figs, 4 tabs

  13. Simulation of proportional control of hydraulic actuator using digital hydraulic valves

    Science.gov (United States)

    Raghuraman, D. R. S.; Senthil Kumar, S.; Kalaiarasan, G.

    2017-11-01

    Fluid power systems using oil hydraulics in earth moving and construction equipment have been using proportional and servo control valves for a long time to achieve precise and accurate position control backed by system performance. Such valves are having feedback control in them and exhibit good response, sensitivity and fine control of the actuators. Servo valves and proportional valves are possessing less hysteresis when compared to on-off type valves, but when the servo valve spools get stuck in one position, a high frequency called as jitter is employed to bring the spool back, whereas in on-off type valves it requires lesser technology to retract the spool. Hence on-off type valves are used in a technology known as digital valve technology, which caters to precise control on slow moving loads with fast switching times and with good flow and pressure control mimicking the performance of an equivalent “proportional valve” or “servo valve”.

  14. Isolating valve, especially in main-steam pipes of power plants

    International Nuclear Information System (INIS)

    Karpenko, A.N.

    1977-01-01

    The valve for PWRs and BWRs, with diameters up to 1.25 m, for temperatures from -180 0 C to about 600 0 C and pressures up to over 50 bar, is designed for high reliability and long useful life. Two circular valve discs are moved as isolating elements in their plane across the steam direction and brought before the valve seat within a valve chamber. Shortly before reaching this final position, each disc is rotated by a small amount about its axis. Only after reaching the final position a double-wedge, further pushed forward between both discs, produces the necessary contact pressure. By revolving and frictionless closing caking together at high stresses and temperature variation is prevented and permanent tightness assured. The valve body is moved in a cylinder, cast on the valve housing, by means of a stepped piston. Its larger diameter is guided in a second cylinder flanged on above. In the cover of the second cylinder a pilot valve is mounted being controlled over 2 parallel solenoid valves by means of compressed air. In normal operation process steam from the valve chamber serves to move the stepped piston with the valve chamber. On closing of a bore, connecting both cylinder spaces, by the pilot valve the main valve is opened. If the pilot valve is opened the steam through the connecting bore is acting on both piston stages and closing the main valve. On loss of steam (pipe break) or for testing purposes one or the other cylinder space over solenoid valves is acted upon by auxiliary energy or evacuated, the main valve thus being controlled. (HP) [de

  15. Remote actuated valve implant

    Science.gov (United States)

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  16. DIAGNOSTICS AND TREATMENT OF MITRAL VALVE PROLAPSE

    Directory of Open Access Journals (Sweden)

    D. A. Kuzhel

    2010-01-01

    Full Text Available The mitral valve prolapse (MVP is one of the most inconsistent diagnose. In the most cases patients with MVP have the good long-term prognosis, and therapy is aimed at reduction in psychovegetative dysfunction. Careful follow-up and timely cardiosurgical correction should be performed, if necessary, in patients with classical MPV. The choice method in these cases is the mitral valve plasty.

  17. Propionibacterium acnes endophthalmitis in Ahmed glaucoma valve.

    Science.gov (United States)

    Gutiérrez-Díaz, E; Montero-Rodríguez, M; Mencía-Gutiérrez, E; Fernández-González, M C; Pérez-Blázquez, E

    2001-01-01

    To report a case of Propionibacterium acnes endophthalmitis in a patient with an Ahmed glaucoma valve. A nine-year-old boy with bilateral congenital glaucoma, with an Ahmed glaucoma valve implanted in the left eye, had recurrent conjunctival dehiscence and endophthalmitis. Vitreous cultures demonstrated the presence of Propionibacterium acnes. This is the first reported case of Propionibacterium acnes endophthalmitis in an Ahmed glaucoma valve and the second one in a glaucoma drainage device. We strongly recommend using a patch graft to prevent and treat tube exposure. Conjunctival grafts may be useful to close the conjunctiva when there is marked scarring to prevent patch exposure and melting or extrusion.

  18. Modeling valve leakage

    International Nuclear Information System (INIS)

    Bell, S.R.; Rohrscheib, R.

    1994-01-01

    The American Society of Mechanical Engineers (ASME) Code requires individual valve leakage testing for Category A valves. Although the U.S. Nuclear Regulatory Commission (USNRC) has recognized that it is more appropriate to test containment isolation valves in groups, as allowed by 10 CFR 50, Appendix J, a utility seeking relief from these Code requirements must provide technical justification for the relief and establish a conservative alternate acceptance criteria. In order to provide technical justification for group testing of containment isolation valves, Illinois Power developed a calculation (model) for determining the size of a leakage pathway in a valve disc or seat for a given leakage rate. The model was verified experimentally by machining leakage pathways of known size and then measuring the leakage and comparing this value to the calculated value. For the range of values typical of leakage rate testing, the correlation between the experimental values and calculated values was quote good. Based upon these results, Illinois Power established a conservative acceptance criteria for all valves in the inservice testing (IST) program and was granted relief by the USNRC from the individual leakage testing requirements of the ASME Code. This paper presents the results of Illinois Power's work in the area of valve leakage rate testing

  19. Mathematical investigation of one-way transform matrix options

    International Nuclear Information System (INIS)

    Cooper, James Arlin

    2006-01-01

    One-way transforms have been used in weapon systems processors since the mid- to late-1970s in order to help recognize insertion of correct pre-arm information while maintaining abnormal-environment safety. Level-One, Level-Two, and Level-Three transforms have been designed. The Level-One and Level-Two transforms have been implemented in weapon systems, and both of these transforms are equivalent to matrix multiplication applied to the inserted information. The Level-Two transform, utilizing a 6 x 6 matrix, provided the basis for the ''System 2'' interface definition for Unique-Signal digital communication between aircraft and attached weapons. The investigation described in this report was carried out to find out if there were other size matrices that would be equivalent to the 6 x 6 Level-Two matrix. One reason for the investigation was to find out whether or not other dimensions were possible, and if so, to derive implementation options. Another important reason was to more fully explore the potential for inadvertent inversion. The results were that additional implementation methods were discovered, but no inversion weaknesses were revealed

  20. Repeat transcatheter aortic valve implantation using a latest generation balloon-expandable device for treatment of failing transcatheter heart valves.

    Science.gov (United States)

    Schaefer, Andreas; Treede, Hendrik; Seiffert, Moritz; Deuschl, Florian; Schofer, Niklas; Schneeberger, Yvonne; Blankenberg, Stefan; Reichenspurner, Hermann; Schaefer, Ulrich; Conradi, Lenard

    2016-01-15

    Paravalvular leakage (PVL) is a known complication of transcatheter aortic valve implantation (TAVI) and is associated with poor outcome. Besides balloon-post-dilatation, valve-in-valve (ViV) procedures can be taken into consideration to control this complication. Herein we present initial experience with use of the latest generation balloon-expandable Edwards Sapien 3® (S3) transcatheter heart valve (THV) for treatment of failing THVs. Between 01/2014 and 12/2014 three patients (two male, age: 71-80 y, log EUROScore I: 11.89 - 32.63) with failing THVs were refered to our institution for further treatment. THV approach with secondary implantation of an S3 was chosen after mutual agreement of the local interdisciplinary heart team at an interval of 533-1119 days from the index procedure. The performed procedures consisted of: S3 in Sapien XT, JenaValve and CoreValve. Successful transfemoral implantation with significant reduction of PVL was achieved in all cases. No intraprocedural complications occurred regarding placement of the S3 with a postprocedural effective orifice area (EOA) of 1.5-2.5 cm(2) and pressure gradients of max/mean 14/6-36/16 mmHg. 30-day mortality was 0%. At the latest follow-up of 90-530 days, all patients are alive and well with satisfactory THV function. Regarding VARC-2 criteria one major bleeding and one TIA was reported. In the instance of moderate or severe aortic regurgitation after TAVI, S3 ViV deployment is an excellent option to reduce residual regurgitation to none or mild. For further assertions concerning functional outcomes long-term results have to be awaited.

  1. Redo mitral valve surgery

    Directory of Open Access Journals (Sweden)

    Redoy Ranjan

    2018-03-01

    Full Text Available This study is based on the findings of a single surgeon’s practice of mitral valve replacement of 167 patients from April 2005 to June 2017 who developed symptomatic mitral restenosis after closed or open mitral commisurotomy. Both clinical and color doppler echocardiographic data of peri-operative and six months follow-up period were evaluated and compared to assess the early outcome of the redo mitral valve surgery. With male-female ratio of 1: 2.2 and after a duration of 6 to 22 years symptom free interval between the redo procedures, the selected patients with mitral valve restenosis undergone valve replacement with either mechanical valve in 62% cases and also tissue valve in 38% cases. Particular emphasis was given to separate the adhered pericardium from the heart completely to ameliorate base to apex and global contraction of the heart. Besides favorable post-operative clinical outcome, the echocardiographic findings were also encouraging as there was statistically significant increase in the mitral valve area and ejection fraction with significant decrease in the left atrial diameter, pressure gradient across the mitral valve and pulmonary artery systolic pressure. Therefore, in case of inevitable mitral restenosis after closed or open commisurotomy, mitral valve replacement is a promising treatment modality.

  2. Delayed-onset streptococcus pyogenes endophthalmitis following Ahmed glaucoma valve implantation.

    Science.gov (United States)

    Bayraktar, Zerrin; Kapran, Ziya; Bayraktar, Sükrü; Acar, Nur; Unver, Yaprak Banu; Gök, Kemran

    2005-01-01

    To report a case of delayed-onset Streptococcus pyogenes endophthalmitis following implantation of an Ahmed glaucoma valve. A 10-year-old patient presented with acute endophthalmitis 1 year after Ahmed glaucoma valve implantation. The conjunctiva and Tenon's capsule over the valve plate had been penetrated by one of the polypropylene fixation sutures. The valve was removed, and pars plana vitrectomy was performed. Vitreous specimens and removal of the discharge over the plate revealed Streptococcus pyogenes. This is the first documented case of Streptococcus pyogenes endophthalmitis following Ahmed glaucoma valve implantation. We think the conjunctival buttonhole caused by the polypropylene suture provided an entry site for the infection. (c) Japanese Ophthalmological Society 2005.

  3. Observation of one-way Einstein-Podolsky-Rosen steering

    Science.gov (United States)

    Händchen, Vitus; Eberle, Tobias; Steinlechner, Sebastian; Samblowski, Aiko; Franz, Torsten; Werner, Reinhard F.; Schnabel, Roman

    2012-09-01

    The distinctive non-classical features of quantum physics were first discussed in the seminal paper by A. Einstein, B. Podolsky and N. Rosen (EPR) in 1935. In his immediate response, E. Schrödinger introduced the notion of entanglement, now seen as the essential resource in quantum information as well as in quantum metrology. Furthermore, he showed that at the core of the EPR argument is a phenomenon that he called steering. In contrast to entanglement and violations of Bell's inequalities, steering implies a direction between the parties involved. Recent theoretical works have precisely defined this property, but the question arose as to whether there are bipartite states showing steering only in one direction. Here, we present an experimental realization of two entangled Gaussian modes of light that in fact shows the steering effect in one direction but not in the other. The generated one-way steering gives a new insight into quantum physics and may open a new field of applications in quantum information.

  4. Evaluating All-Metal Valves for Use in a Tritium Environment

    Energy Technology Data Exchange (ETDEWEB)

    Houk, L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Payton, A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-09-28

    In the tritium gas processing system, it is desired to minimize polymer components due to their degradation from tritium exposure (beta decay). One source of polymers in the tritium process is valve components. A vendor has been identified that manufactures a valve that is marketed as being made from all-metal construction. This manufacturer, Ham-Let Group, manufactures a diaphragm valve (3LE series) that claims to be made entirely of metal. SRNL procured twelve (12) Ham-Let diaphragm valves for characterization and evaluation. The characterization tests include identification of the maximum pressure of these valves by performing pressure and burst tests. Leak tests were performed to ensure the valves do not exceed the acceptable leak rate for tritium service. These valves were then cycled in a nitrogen gas and/or vacuum environment to ensure they would be durable in a process environment. They were subsequently leak tested per ASTM protocol to ensure that the valves maintained their leak tight integrity. A detailed material analysis was also conducted to determine hydrogen and tritium compatibility.

  5. Guide to prosthetic cardiac valves

    International Nuclear Information System (INIS)

    Morse, D.; Steiner, R.M.; Fernandez, J.

    1985-01-01

    This book contains 10 chapters. Some of the chapter titles are: The development of artificial heart valves: Introduction and historical perspective; The radiology of prosthetic heart valves; The evaluation of patients for prosthetic valve implantation; Pathology of cardiac valve replacement; and Bioengineering of mechanical and biological heart valve substitutes

  6. Next-generation nozzle check valve significantly reduces operating costs

    Energy Technology Data Exchange (ETDEWEB)

    Roorda, O. [SMX International, Toronto, ON (Canada)

    2009-01-15

    Check valves perform an important function in preventing reverse flow and protecting plant and mechanical equipment. However, the variety of different types of valves and extreme differences in performance even within one type can change maintenance requirements and life cycle costs, amounting to millions of dollars over the typical 15-year design life of piping components. A next-generation non-slam nozzle check valve which prevents return flow has greatly reduced operating costs by protecting the mechanical equipment in a piping system. This article described the check valve varieties such as the swing check valve, a dual-plate check valve, and nozzle check valves. Advancements in optimized design of a non-slam nozzle check valve were also discussed, with particular reference to computer flow modelling such as computational fluid dynamics; computer stress modelling such as finite element analysis; and flow testing (using rapid prototype development and flow loop testing), both to improve dynamic performance and reduce hydraulic losses. The benefits of maximized dynamic performance and minimized pressure loss from the new designed valve were also outlined. It was concluded that this latest non-slam nozzle check valve design has potential applications in natural gas, liquefied natural gas, and oil pipelines, including subsea applications, as well as refineries, and petrochemical plants among others, and is suitable for horizontal and vertical installation. The result of this next-generation nozzle check valve design is not only superior performance, and effective protection of mechanical equipment but also minimized life cycle costs. 1 fig.

  7. BWR control rod drive scram pilot valve monitoring system

    International Nuclear Information System (INIS)

    Soden, R.A.; Kelly, V.

    1984-01-01

    The control rod drive system in a Boiling Water Reactor is the most important safety system in the power plant. All components of the system can be verified except the solenoid operated, scram pilot valves without scramming a rod. The pilot valve mechancial works is the weak link to the control rod drive system. These pilot valves control the hydraulic system which applies pressure to the ''insert'' side of the control rod piston and vents the ''withdraw'' side of the piston causing the rods to insert during a scam. The only verification that the valve is operating properly is to scram the rod. The concern for this portion of the system is demonstrated by the high number of redundant components and complete periodic testing of the electrical circuits. The pilot valve can become hung-up through wear, fracture of internal components, mechanical binding, foreign material or chemicals left in the valve during maintenance, etc. If the valve becomes hung-up the electrical tests performed will not indicate this condition and scramming the rod is in jeopardy. Only an attempt to scram a rod will indicate the hung-up valve. While this condition exists the rod is considered inoperative. This paper describes a system developed at a nuclear power plant that monitors the pilot valves on the control rod drive system. This system utilizes pattern recognition to assure proper internal workings of the scram pilot valves to plant operators. The system is totally automatic such that each time the valve is operated on a ''half scram'', a printout is available to the operator along with light indication that each of the 370 valves (on one unit of a BWR) is operating properly. With this monitoring system installed, all components of the control rod drive system including the solenoid pilot valves can be verified as operational without scramming any rods

  8. BWR control rod drive scram pilot valve monitoring program

    International Nuclear Information System (INIS)

    Soden, R.A.; Kelly, V.

    1986-01-01

    The control rod drive system in a Boiling Water Reactor is the most important safety system in the power plant. All components of the system can be verified except the solenoid operated, scram pilot valves without scramming a rod. The pilot valve mechanical works is the weak link to the control rod drive system. These pilot valves control the hydraulic system which applies pressure to the insert side of the control rod piston and vents the withdraw side of the piston causing the rods to insert during a scram. The only verification that the valve is operating properly is to scram the rod. The concern for this portion of the system is demonstrated by the high number of redundant components and complete periodic testing of the electrical circuits. The pilot valve can become hung-up through wear, fracture of internal components, mechanical binding, foreign material or chemicals left in the valve during maintenance, etc. If the valve becomes hung-up the electrical tests performed will not indicate this condition and scramming the rod is in jeopardy. Only an attempt to scram a rod will indicate the hung-up valve. While this condition exists the rod is considered inoperative. This paper describes a system developed at a nuclear power plant that monitors the pilot valves on the control rod drive system. This system utilizes pattern recognition to assure proper internal workings of the scram pilot valves to plant operators. The system is totally automatic such that each time the valve is operated on a half scram, a printout is available to the operator along with light indication that each of the 370 valves (on one unit of a BWR) is operating properly. With this monitoring system installed, all components of the control rod drive system including the solenoid pilot valves can be verified as operational without scramming any rods

  9. Modification and performance evaluation of a mono-valve engine

    Science.gov (United States)

    Behrens, Justin W.

    A four-stroke engine utilizing one tappet valve for both the intake and exhaust gas exchange processes has been built and evaluated. The engine operates under its own power, but has a reduced power capacity than the conventional 2-valve engine. The reduction in power is traced to higher than expected amounts of exhaust gases flowing back into the intake system. Design changes to the cylinder head will fix the back flow problems, but the future capacity of mono-valve engine technology cannot be estimated. The back flow of exhaust gases increases the exhaust gas recirculation (EGR) rate and deteriorates combustion. Intake pressure data shows the mono-valve engine requires an advanced intake valve closing (IVC) time to prevent back flow of charge air. A single actuation camshaft with advanced IVC was tested in the mono-valve engine, and was found to improve exhaust scavenging at TDC and nearly eliminated all charge air back flow at IVC. The optimum IVC timing is shown to be approximately 30 crank angle degrees after BDC. The mono-valve cylinder head utilizes a rotary valve positioned above the tappet valve. The open spaces inside the rotary valveand between the rotary valve and tappet valve represent a common volume that needs to be reduced in order to reduce the base EGR rate. Multiple rotary valve configurations were tested, and the size of the common volume was found to have no effect on back flow but a direct effect on the EGR rate and engine performance. The position of the rotary valve with respect to crank angle has a direct effect on the scavenging process. Optimum scavenging occurs when the intake port is opened just after TDC.

  10. A unique case of a huge mixed squamous cell and glandular papilloma of non-endobronchial origin with a peripheral growth

    Directory of Open Access Journals (Sweden)

    Kei Yabuki

    Full Text Available We report a case of a huge solitary non-endobronchial pulmonary tumor in a 76-year-old male smoker. The tumor measured 11 × 10 × 8 cm. It was ill-defined, and it was located periphery of the right lower lobe with the subpleural cystic spaces. He underwent right lower lobectomy with mediastinal lymph node dissection and is free from tumor 30 months after surgery. Microscopically, it was composed of a proliferation of squamous and ciliated columnar epithelial cells with a few mucous cells. These cells were arranged in a papillary growth fashion extending along the fibrously thickened alveolar septa together with metaplastic bronchiolar and squamous epithelia displaying an usual interstitial pneumonia-pattern. Although the histologic features of the tumor were that of a mixed squamous cell and glandular papilloma (MSCGP, it was peripherally located and showed a lepidic growth, and it was much larger than previously reported MSCGPs. It is possible that the tumor developed in association with bronchial metaplasia in the periphery of the lung, and then extended along the surface of the reconstructed air spaces, which resulted in its unique histologic appearance. Further investigations of respiratory papilloma are needed to clarify the pathogenesis of these lesions. Keywords: Mixed squamous cell and glandular papilloma, Non-endobronchial, Cytology, Interstitial pneumonia, Pulmonary tumor

  11. Early clinical outcome of aortic transcatheter valve-in-valve implantation in the Nordic countries

    DEFF Research Database (Denmark)

    Ihlberg, Leo; Nissen, Henrik Hoffmann; Nielsen, Niels Erik

    2013-01-01

    Transcatheter valve-in-valve implantation has emerged as an option, in addition to reoperative surgical aortic valve replacement, to treat failed biologic heart valve substitutes. However, the clinical experience with this approach is still limited. We report the comprehensive experience...

  12. Nuclear valves latest development

    International Nuclear Information System (INIS)

    Isaac, F.; Monier, M.

    1993-01-01

    In the frame of Nuclear Power Plant upgrade (Emergency Power Supply and Emergency Core Cooling), Westinghouse had to face a new valve design philosophy specially for motor operated valves. The valves have to been designed to resist any operating conditions, postulated accident or loss of control. The requirements for motor operated valves are listed and the selected model and related upgrading explained. As part of plant upgrade and valves replacement, Westinghouse has sponsored alternative hardfacing research programme. Two types of materials have been investigated: nickel base alloys and iron base alloys. Programme requirements and test results are given. A new globe valve model (On-Off or regulating) is described developed by Alsthom Velan permitting the seat replacement in less than 10 min. (Z.S.) 2 figs

  13. Magnetic Check Valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-01-01

    Poppet in proposed check valve restored to closed condition by magnetic attraction instead of spring force. Oscillations suppressed, with consequent reduction of wear. Stationary magnetic disk mounted just upstream of poppet, also containing magnet. Valve body nonmagnetic. Forward pressure or flow would push poppet away from stationary magnetic disk so fluid flows easily around poppet. Stop in valve body prevents poppet from being swept away. When flow stopped or started to reverse, magnetic attraction draws poppet back to disk. Poppet then engages floating O-ring, thereby closing valve and preventing reverse flow. Floating O-ring facilitates sealing at low loads.

  14. Effects of valve timing, valve lift and exhaust backpressure on performance and gas exchanging of a two-stroke GDI engine with overhead valves

    International Nuclear Information System (INIS)

    Dalla Nora, Macklini; Lanzanova, Thompson Diórdinis Metzka; Zhao, Hua

    2016-01-01

    Highlights: • Two-stroke operation was achieved in a four-valve direct injection gasoline engine. • Shorter valve opening durations improved torque at lower engine speeds. • The longer the valve opening duration, the lower was the air trapping efficiency. • Higher exhaust backpressure and lower valve lift reduced the compressor work. - Abstract: The current demand for fuel efficient and lightweight powertrains, particularly for application in downsized and hybrid electric vehicles, has renewed the interest in two-stroke engines. In this framework, an overhead four-valve spark-ignition gasoline engine was modified to run in the two-stroke cycle. The scavenging process took place during a long valve overlap period around bottom dead centre at each crankshaft revolution. Boosted intake air was externally supplied at a constant pressure and gasoline was directly injected into the cylinder after valve closure. Intake and exhaust valve timings and lifts were independently varied through an electrohydraulic valve train, so their effects on engine performance and gas exchanging were investigated at 800 rpm and 2000 rpm. Different exhaust backpressures were also evaluated by means of exhaust throttling. Air trapping efficiency, charging efficiency and scavenge ratio were calculated based on air and fuel flow rates, and exhaust oxygen concentration at fuel rich conditions. The results indicated that longer intake and exhaust valve opening durations increased the charge purity and hence torque at higher engine speeds. At lower speeds, although, shorter valve opening durations increased air trapping efficiency and reduced the estimated supercharger power consumption due to lower air short-circuiting. A strong correlation was found between torque and charging efficiency, while air trapping efficiency was more associated to exhaust valve opening duration. The application of exhaust backpressure, as well as lower intake/exhaust valve lifts, made it possible to increase

  15. Anterior mitral valve aneurysm: a rare sequelae of aortic valve endocarditis

    Directory of Open Access Journals (Sweden)

    Rajesh Janardhanan

    2016-05-01

    Full Text Available In intravenous drug abusers, infective endocarditis usually involves right-sided valves, with Staphylococcus aureus being the most common etiologic agent. We present a patient who is an intravenous drug abuser with left-sided (aortic valve endocarditis caused by Enterococcus faecalis who subsequently developed an anterior mitral valve aneurysm, which is an exceedingly rare complication. A systematic literature search was conducted which identified only five reported cases in the literature of mitral valve aneurysmal rupture in the setting of E. faecalis endocarditis. Real-time 3D-transesophageal echocardiography was critical in making an accurate diagnosis leading to timely intervention. Learning objectives: • Early recognition of a mitral valve aneurysm (MVA is important because it may rupture and produce catastrophic mitral regurgitation (MR in an already seriously ill patient requiring emergency surgery, or it may be overlooked at the time of aortic valve replacement (AVR. • Real-time 3D-transesophageal echocardiography (RT-3DTEE is much more advanced and accurate than transthoracic echocardiography for the diagnosis and management of MVA.

  16. Anterior mitral valve aneurysm: a rare sequelae of aortic valve endocarditis.

    Science.gov (United States)

    Janardhanan, Rajesh; Kamal, Muhammad Umar; Riaz, Irbaz Bin; Smith, M Cristy

    2016-03-01

    SummaryIn intravenous drug abusers, infective endocarditis usually involves right-sided valves, with Staphylococcus aureus being the most common etiologic agent. We present a patient who is an intravenous drug abuser with left-sided (aortic valve) endocarditis caused by Enterococcus faecalis who subsequently developed an anterior mitral valve aneurysm, which is an exceedingly rare complication. A systematic literature search was conducted which identified only five reported cases in the literature of mitral valve aneurysmal rupture in the setting of E. faecalis endocarditis. Real-time 3D-transesophageal echocardiography was critical in making an accurate diagnosis leading to timely intervention. Early recognition of a mitral valve aneurysm (MVA) is important because it may rupture and produce catastrophic mitral regurgitation (MR) in an already seriously ill patient requiring emergency surgery, or it may be overlooked at the time of aortic valve replacement (AVR).Real-time 3D-transesophageal echocardiography (RT-3DTEE) is much more advanced and accurate than transthoracic echocardiography for the diagnosis and management of MVA. © 2016 The authors.

  17. One Way to Holland’

    DEFF Research Database (Denmark)

    Marselis, Randi; Schütze, Laura Maria

    2013-01-01

    museums, but is also relevant to ongoing collection practices. An important theme in relation to source communities is ownership and repatriation of cultural objects. Furthermore, working with source communities implies a two-way information process through which groups are given access to memory...

  18. Ureteral valve masquerading as obstructive megaureter

    Directory of Open Access Journals (Sweden)

    Sushmita Bhatnagar

    2017-05-01

    Full Text Available Primary obstructed megaureter is a common urological condition in the pediatric age group. It is one of the differentials for congenital anomalies of the kidney and urinary tract that include a myriad of structural anomalies of the urinary tract. The obstructive conditions are usually managed conservatively unless there is deterioration in renal function, repeated urinary tract infection, or any other symptom such as abdominal pain on ipsilateral side and hypertension. Presented here is a case of left lower ureteral valve that was diagnosed as primary obstructed megaureter with pain in abdomen and reduced ipsilateral renal function wherein ureteral valve was detected incidentally intraoperatively. Excision of the valve with end to end uretero-ureteral anastomoses over a D-J stent, without resorting to ureteric reimplantation was successful in relieving the obstruction and hydronephrosis

  19. Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John; Brecker, Stephen

    2012-01-01

    Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry....

  20. Transcatheter aortic valve replacement

    Science.gov (United States)

    ... gov/ency/article/007684.htm Transcatheter aortic valve replacement To use the sharing features on this page, please enable JavaScript. Transcatheter aortic valve replacement (TAVR) is surgery to replace the aortic valve. ...

  1. Overflow control valve

    International Nuclear Information System (INIS)

    Kessinger, B.A.; Hundal, R.; Parlak, E.A.

    1982-01-01

    An overflow control valve for use in a liquid sodium coolant pump tank which can be remotely engaged with and disengaged from the pump tank wall to thereby permit valve removal. An actuating shaft for controlling the valve also has means for operating a sliding cylinder against a spring to retract the cylinder from sealing contact with the pump tank nozzle. (author)

  2. The prognosis of infective endocarditis treated with biological valves versus mechanical valves: A meta-analysis.

    Science.gov (United States)

    Tao, Ende; Wan, Li; Wang, WenJun; Luo, YunLong; Zeng, JinFu; Wu, Xia

    2017-01-01

    Surgery remains the primary form of treatment for infective endocarditis (IE). However, it is not clear what type of prosthetic valve provides a better prognosis. We conducted a meta-analysis to compare the prognosis of infective endocarditis treated with biological valves to cases treated with mechanical valves. Pubmed, Embase and Cochrane databases were searched from January 1960 to November 2016.Randomized controlled trials, retrospective cohorts and prospective studies comparing outcomes between biological valve and mechanical valve management for infective endocarditis were analyzed. The Newcastle-Ottawa Scale(NOS) was used to evaluate the quality of the literature and extracted data, and Stata 12.0 software was used for the meta-analysis. A total of 11 publications were included; 10,754 cases were selected, involving 6776 cases of biological valves and 3,978 cases of mechanical valves. The all-cause mortality risk of the biological valve group was higher than that of the mechanical valve group (HR = 1.22, 95% CI 1.03 to 1.44, P = 0.023), as was early mortality (RR = 1.21, 95% CI 1.02 to 1.43, P = 0.033). The recurrence of endocarditis (HR = 1.75, 95% CI 1.26 to 2.42, P = 0.001), as well as the risk of reoperation (HR = 1.79, 95% CI 1.15 to 2.80, P = 0.010) were more likely to occur in the biological valve group. The incidence of postoperative embolism was less in the biological valve group than in the mechanical valve group, but this difference was not statistically significant (RR = 0.90, 95% CI 0.76 to 1.07, P = 0.245). For patients with prosthetic valve endocarditis (PVE), there was no significant difference in survival rates between the biological valve group and the mechanical valve group (HR = 0.91, 95% CI 0.68 to 1.21, P = 0.520). The results of our meta-analysis suggest that mechanical valves can provide a significantly better prognosis in patients with infective endocarditis. There were significant differences in the clinical features of patients

  3. Fluid mechanics of heart valves.

    Science.gov (United States)

    Yoganathan, Ajit P; He, Zhaoming; Casey Jones, S

    2004-01-01

    Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.

  4. Old trims for new: the cheaper solution to valve problems

    Energy Technology Data Exchange (ETDEWEB)

    Katz, B [Control Components, Inc., Rancho Santa Margarita, CA (United States)

    1994-01-01

    Rather than replacing a faulty valve - or one that is simply not up to the job - it has been possible to retrofit a variety of valve types used in nuclear plants with new trims which are described briefly. (Author).

  5. Old trims for new: the cheaper solution to valve problems

    International Nuclear Information System (INIS)

    Katz, B.

    1994-01-01

    Rather than replacing a faulty valve - or one that is simply not up to the job - it has been possible to retrofit a variety of valve types used in nuclear plants with new trims which are described briefly. (Author)

  6. Intelligent Flow Control Valve

    Science.gov (United States)

    Kelley, Anthony R (Inventor)

    2015-01-01

    The present invention is an intelligent flow control valve which may be inserted into the flow coming out of a pipe and activated to provide a method to stop, measure, and meter flow coming from the open or possibly broken pipe. The intelligent flow control valve may be used to stop the flow while repairs are made. Once repairs have been made, the valve may be removed or used as a control valve to meter the amount of flow from inside the pipe. With the addition of instrumentation, the valve may also be used as a variable area flow meter and flow controller programmed based upon flowing conditions. With robotic additions, the valve may be configured to crawl into a desired pipe location, anchor itself, and activate flow control or metering remotely.

  7. Experience with valves for PHWR reactors

    International Nuclear Information System (INIS)

    Narayan, K.; Mhetre, S.G.

    1977-01-01

    Material specifications and inspection and testing requirements of the valves meant for use in nuclear reactors are mentioned. In the heavy water systems (both primary and moderator) of a PHWR type reactor, the valves used are gate valves, globe valves, diaphragm valves, butterfly valves, check valves and relief valves. Their locations and functions they perform in the Rajasthan Atomic Power Station Unit-1 are described. Experience with them is given. The major problems encountered with them have been : (1) leakage from the stem seals and body bonnet joint, (2) leakage due to failure of diaphragm and/or washout of the packing and (3) malfunctioning. Measures taken to solve these are discussed. Finally a mention has been made of improved versions of valves, namely, metal diaphragm valve and inverted relief valve. (M.G.B.)

  8. Experimental realization of a quantum game on a one-way quantum computer

    International Nuclear Information System (INIS)

    Prevedel, Robert; Stefanov, Andre; Walther, Philip; Zeilinger, Anton

    2007-01-01

    We report the first demonstration of a quantum game on an all-optical one-way quantum computer. Following a recent theoretical proposal we implement a quantum version of Prisoner's Dilemma, where the quantum circuit is realized by a four-qubit box-cluster configuration and the player's local strategies by measurements performed on the physical qubits of the cluster. This demonstration underlines the strength and versatility of the one-way model and we expect that this will trigger further interest in designing quantum protocols and algorithms to be tested in state-of-the-art cluster resources

  9. Fabrication of micro metallic valve and pump

    Science.gov (United States)

    Yang, Ming; Kabasawa, Yasunari; Ito, Kuniyoshi

    2010-03-01

    Fabrication of micro devices by using micro metal forming was proposed by the authors. We developed a desktop servo-press machine with precise tooling system. Precise press forming processes including micro forging and micro joining has been carried out in a progressive die. In this study, micro metallic valve and pump were fabricated by using the precise press forming. The components are made of sheet metals, and assembled in to a unit in the progressive die. A micro check-valve with a diameter of 3mm and a length of 3.2mm was fabricated, and the property of flow resistance was evaluated. The results show that the check valve has high property of leakage proof. Since the valve is a unit parts with dimensions of several millimeters, it has advantage to be adapted to various pump design. Here, two kinds of micro pumps with the check-valves were fabricated. One is diaphragm pump actuated by vibration of the diaphragm, and another is tube-shaped pump actuated by resonation. The flow quantities of the pumps were evaluated and the results show that both of the pumps have high pumping performance.

  10. Leaving Moderate Tricuspid Valve Regurgitation Alone at the Time of Pulmonary Valve Replacement: A Worthwhile Approach.

    Science.gov (United States)

    Kogon, Brian; Mori, Makoto; Alsoufi, Bahaaldin; Kanter, Kirk; Oster, Matt

    2015-06-01

    Pulmonary valve disruption in patients with tetralogy of Fallot and congenital pulmonary stenosis often results in pulmonary insufficiency, right ventricular dilation, and tricuspid valve regurgitation. Management of functional tricuspid regurgitation at the time of subsequent pulmonary valve replacement remains controversial. Our aims were to (1) analyze tricuspid valve function after pulmonary valve replacement through midterm follow-up and (2) determine the benefits, if any, of concomitant tricuspid annuloplasty. Thirty-five patients with tetralogy of Fallot or congenital pulmonary stenosis were analyzed. All patients had been palliated in childhood by disrupting the pulmonary valve, and all patients had at least moderate tricuspid valve regurgitation at the time of subsequent pulmonary valve replacement. Preoperative and serial postoperative echocardiograms were analyzed. Pulmonary and tricuspid regurgitation, along with right ventricular dilation and dysfunction were scored as 0 (none), 1 (mild), 2 (moderate), and 3 (severe). Right ventricular volume and area were also calculated. Comparisons were made between patients who underwent pulmonary valve replacement alone and those who underwent concomitant tricuspid valve annuloplasty. At 1 month after pulmonary valve replacement, there were significant reductions in pulmonary valve regurgitation (mean 3 vs 0.39, p tricuspid valve regurgitation (mean 2.33 vs 1.3, p tricuspid regurgitation 1 month postoperatively between patients who underwent concomitant tricuspid annuloplasty and those who underwent pulmonary valve replacement alone (mean 1.31 vs 1.29, p = 0.81). However, at latest follow-up (mean 7.0 ± 2.8 years), the degree of tricuspid regurgitation was significantly higher in the concomitant annuloplasty group (mean 1.87 vs 1.12, p = 0.005). In patients with at least moderate tricuspid valve regurgitation, significant improvement in tricuspid valve function and right ventricular size occurs in the first

  11. True amplitude wave equation migration arising from true amplitude one-way wave equations

    Science.gov (United States)

    Zhang, Yu; Zhang, Guanquan; Bleistein, Norman

    2003-10-01

    One-way wave operators are powerful tools for use in forward modelling and inversion. Their implementation, however, involves introduction of the square root of an operator as a pseudo-differential operator. Furthermore, a simple factoring of the wave operator produces one-way wave equations that yield the same travel times as the full wave equation, but do not yield accurate amplitudes except for homogeneous media and for almost all points in heterogeneous media. Here, we present augmented one-way wave equations. We show that these equations yield solutions for which the leading order asymptotic amplitude as well as the travel time satisfy the same differential equations as the corresponding functions for the full wave equation. Exact representations of the square-root operator appearing in these differential equations are elusive, except in cases in which the heterogeneity of the medium is independent of the transverse spatial variables. Here, we address the fully heterogeneous case. Singling out depth as the preferred direction of propagation, we introduce a representation of the square-root operator as an integral in which a rational function of the transverse Laplacian appears in the integrand. This allows us to carry out explicit asymptotic analysis of the resulting one-way wave equations. To do this, we introduce an auxiliary function that satisfies a lower dimensional wave equation in transverse spatial variables only. We prove that ray theory for these one-way wave equations leads to one-way eikonal equations and the correct leading order transport equation for the full wave equation. We then introduce appropriate boundary conditions at z = 0 to generate waves at depth whose quotient leads to a reflector map and an estimate of the ray theoretical reflection coefficient on the reflector. Thus, these true amplitude one-way wave equations lead to a 'true amplitude wave equation migration' (WEM) method. In fact, we prove that applying the WEM imaging condition

  12. Endobronchial Ultrasound-guided Transbronchial Needle Injection of Liposomal Amphotericin B for the Treatment of Symptomatic Aspergilloma.

    Science.gov (United States)

    Parikh, Mihir S; Seeley, Eric; Nguyen-Tran, Evelyn; Krishna, Ganesh

    2017-10-01

    Surgical treatment with lung resection has traditionally been the treatment of choice for pulmonary cavities containing aspergillomas that cause hemoptysis. Endobronchial ultrasound (EBUS) is a minimally invasive bronchoscopic technique that is commonly used for transbronchial needle aspiration of hilar and mediastinal lymph nodes as well as centrally located parenchymal lesions. Here, we describe a case of a 71-year-old woman who was found to have a cavitary lesion in the lung containing aspergillomas. Under direct ultrasound visualization with EBUS, liposomal amphotericin B was injected into the aspergillomas. These aspergillomas regressed after treatment. To our knowledge, this is the first reported treatment of aspergilloma with EBUS-guided transbronchial needle injection of liposomal amphotericin B.

  13. On the experimental determination of the one-way speed of light

    International Nuclear Information System (INIS)

    Perez, Israel

    2011-01-01

    In this paper the question of the isotropy of the one-way speed of light is addressed from an experimental perspective. In particular, we analyse two experimental methods commonly used in its determination. The analysis is aimed at clarifying the view that the one-way speed of light cannot be determined by techniques in which physical entities close paths. The procedure employed here will provide epistemological tools so that physicists understand that a direct measurement of the speed not only of light but of any physical entity is by no means trivial. Our results shed light on the physics behind the experiments which may be of interest for both physicists with an elemental knowledge in special relativity and philosophers of science.

  14. On the experimental determination of the one-way speed of light

    Energy Technology Data Exchange (ETDEWEB)

    Perez, Israel, E-mail: cooguion@yahoo.com, E-mail: iperez@cicese.mx [Department of Applied Physics, Optics Division, CICESE, Carretera Ensena da-Tijuana 3918, Zona Playitas, CP 22860, Ensenada, Baja California (Mexico)

    2011-07-15

    In this paper the question of the isotropy of the one-way speed of light is addressed from an experimental perspective. In particular, we analyse two experimental methods commonly used in its determination. The analysis is aimed at clarifying the view that the one-way speed of light cannot be determined by techniques in which physical entities close paths. The procedure employed here will provide epistemological tools so that physicists understand that a direct measurement of the speed not only of light but of any physical entity is by no means trivial. Our results shed light on the physics behind the experiments which may be of interest for both physicists with an elemental knowledge in special relativity and philosophers of science.

  15. Acoustic one-way mode conversion and transmission by sonic crystal waveguides

    Science.gov (United States)

    Ouyang, Shiliang; He, Hailong; He, Zhaojian; Deng, Ke; Zhao, Heping

    2016-09-01

    We proposed a scheme to achieve one-way acoustic propagation and even-odd mode switching in two mutually perpendicular sonic crystal waveguides connected by a resonant cavity. The even mode in the entrance waveguide is able to switch to the odd mode in the exit waveguide through a symmetry match between the cavity resonant modes and the waveguide modes. Conversely, the odd mode in the exit waveguide is unable to be converted into the even mode in the entrance waveguide as incident waves and eigenmodes are mismatched in their symmetries at the waveguide exit. This one-way mechanism can be applied to design an acoustic diode for acoustic integration devices and can be used as a convertor of the acoustic waveguide modes.

  16. Hydraulic High Pressure Valve Controller Using the In-Situ Pressure Difference

    Science.gov (United States)

    Bao, Xiaoqi (Inventor); Sherrit, Stewart (Inventor); Badescu, Mircea (Inventor); Bar-Cohen, Yoseph (Inventor); Hall, Jeffery L. (Inventor)

    2016-01-01

    A hydraulic valve controller that uses an existing pressure differential as some or all of the power source for valve operation. In a high pressure environment, such as downhole in an oil or gas well, the pressure differential between the inside of a pipe and the outside of the pipe may be adequately large to drive a linear slide valve. The valve is operated hydraulically by a piston in a bore. When a higher pressure is applied to one end of the bore and a lower pressure to the other end, the piston moves in response to the pressure differential and drives a valve attached to it. If the pressure differential is too small to drive the piston at a sufficiently high speed, a pump is provided to generate a larger pressure differential to be applied. The apparatus is conveniently constructed using multiport valves, which can be rotary valves.

  17. The Double-Orifice Valve Technique to Treat Tricuspid Valve Incompetence.

    Science.gov (United States)

    Hetzer, Roland; Javier, Mariano; Delmo Walter, Eva Maria

    2016-01-01

    A straightforward tricuspid valve (TV) repair technique was used to treat either moderate or severe functional (normal valve with dilated annulus) or for primary/organic (Ebstein's anomaly, leaflet retraction/tethering and chordal malposition/tethering, with annular dilatation) TV incompetence, and its long-term outcome assessed. A double-orifice valve technique was employed in 91 patients (mean age 52.6 ± 23.2 years; median age 56 years; range: 0.6-82 years) with severe tricuspid regurgitation. Among the patients, three had post-transplant iatrogenic chordal rupture, five had infective endocarditis, 11 had mitral valve insufficiency, 23 had Ebstein's anomaly, and 47 had isolated severe TV incompetence. The basic principle was to reduce the distance between the coapting leaflets, wherein the most mobile leaflet could coapt to the opposite leaflet, by creating two orifices, ensuring valve competence. The TV repair was performed through a median sternotomy or right anterior thoracotomy in the fifth intercostal space under cardiopulmonary bypass. The degree and extent of creating a double-valve orifice was determined by considering the minimal body surface area (BSA)-related acceptable TV diameter. Repair was accomplished by passing pledgeted mattress sutures from the middle of the true anterior annulus to a spot on the opposite septal annulus, located approximately two-thirds of the length of the septal annulus to avoid injury to the bundle of His. The annular apposition divides the TV into a larger anterior and a smaller posterior orifices, enabling valve closure, on both sides. In adults, the diameter of the anterior valve orifice should be 23-25 mm, and the posterior orifice 15-18 mm; thus, the total valve orifice area is 5-6 cm2. In children, the total valve orifice should be a standard deviation of 1.7 mm for a BSA of 1.0m2. During a mean follow up of 8.7 ± 1.34 years (median 10 years; range: 1.5-25.9 years) there have been no reoperations for TV insufficiency

  18. Percutaneous aortic valve implantation of the Medtronic CoreValve self-expanding valve prosthesis via left subclavian artery access: the first case report in Greece.

    Science.gov (United States)

    Karavolias, George K; Georgiadou, Panagiota; Houri, Mazen; Sbarouni, Eftihia; Thomopoulou, Sofia; Tsiapras, Dimitrios; Smirli, Anna; Balanika, Marina; Voudris, Vassilis

    2010-01-01

    This case report describes a percutaneous aortic valve implantation with the Medtronic CoreValve selfexpanding valve prosthesis in a patient with severe aortic stenosis. The approach was made via the left subclavian artery because of the lack of femoral vessel access. The patient was a 78-year-old female with breathlessness on minimal effort, a recent hospitalisation due to pulmonary oedema, and frequent episodes of pre-syncope; surgical valve replacement had been ruled out. The prosthetic valve was successfully implanted with mild paravalvular aortic regurgitation. At 30 days, the patient's clinical condition had significantly improved, with excellent functioning of the aortic valve prosthesis.

  19. Tricuspid valve repair for severe tricuspid regurgitation due to pacemaker leads.

    Science.gov (United States)

    Uehara, Kyokun; Minakata, Kenji; Watanabe, Kentaro; Sakaguchi, Hisashi; Yamazaki, Kazuhiro; Ikeda, Tadashi; Sakata, Ryuzo

    2016-07-01

    Tricuspid valve regurgitation due to pacemaker leads is a well-known complication. Although some reports have suggested that pacemaker leads should be surgically explanted, strongly adhered leads cannot always be removed. The aim of this study was to describe our tricuspid valve repair techniques with pacemaker leads left in situ. Our retrospective study investigated 6 consecutive patients who required tricuspid valve surgery for severe regurgitation induced by pacemaker leads. From the operative findings, we identified 3 patterns of tricuspid valve and pacemaker lead involvement. In 3 patients, the leads were caught in the chordae, in 2 patients, tricuspid regurgitation was caused by lead impingement on the septal leaflet, and in 3 patients, tricuspid valve leaflets had been perforated by the pacemaker leads. During surgery, all leads were left in situ after being separated from the leaflet or valvular apparatus. In addition, suture annuloplasty was performed for annular dilatation in all cases. In one patient, the lead was reaffixed to the annulus after the posterior leaflet was cut back towards the annulus, and the leaflet was then closed. There was one hospital death due to sepsis. The degree of tricuspid regurgitation was trivial in all surviving patients at discharge. During a mean follow-up of 21 months, one patient died from pneumonia 20 months after tricuspid valve repair. In patients undergoing tricuspid valve surgery due to severe tricuspid regurgitation caused by pacemaker leads, the leads can be left in situ after proper repair with annuloplasty. © The Author(s) 2016.

  20. Flow oscillations on the steam control valve in the middle opening condition. Clarification of the effects of valve body and valve seat by steam experiments

    International Nuclear Information System (INIS)

    Morita, Ryo; Inada, Fumio

    2007-01-01

    A steam control valve might cause vibrations of piping when the valve opening is in a middle condition. For rationalization of maintenance and management of the plant, the valve should be improved, but it is difficult to understand flow characteristics in detail by experiment because flow around the valve is complex 3D structure and becomes supersonic (M>1). Therefore, it is necessary to clarify the cause of the vibrations and to develop the countermeasures by CFD (Computational Fluid Dynamics) technology. In previous researches, we clarified a mechanism of the pressure fluctuations in the middle opening condition and suggested the new valve shape (named 'Extended Valve') that can suppress the pressure fluctuations by air experiments and CFD calculations. Then, we also conducted steam experiments and CFD calculations to understand the differences between air and the steam, and found that the pressure fluctuations in the middle opening condition also occurred in the steam tests and the differences between the air and steam were not remarkable. In this report, to clarify the effects of valve and valve seat shape in steam flow condition, we conduct the steam experiments with various valve and seat shape. As a result, we find the change of the valve seat can decrease the amplitude of pressure fluctuations, but can not quite suppress the pressure fluctuations in the middle opening condition. Then, we apply the 'Extended Valve' to clarify the valve shape effect, and find that the extended valve suppresses the pressure fluctuations in the middle opening condition completely and decreases the pressure amplitude drastically. (author)

  1. Plant experience with check valves in passive systems

    Energy Technology Data Exchange (ETDEWEB)

    Pahladsingh, R R [GKN Joint Nuclear Power Plant, Dodewaard (Netherlands)

    1996-12-01

    In the design of the advanced nuclear reactors there is a tendency to introduce more passive safety systems. The 25 year old design of the GKN nuclear reactor is different from the present BWR reactors because of some special features, such as the Natural Circulation - and the Passive Isolation Condenser system. When reviewing the design, one can conclude that the plant has 25 years of experience with check valves in passive systems and as passive components in systems. The result of this experience has been modeled in a plant-specific ``living PSA`` for the plant. A data-analysis has been performed on components which are related to the safety systems in the plant. As part of this study also the check valves have been taken in consideration. At GKN, the check valves have shown to be reliable components in the systems and no catastrophic failures have been experienced during the 25 years of operation. Especially the Isolation Condenser with its operation experience can contribute substantially to the insight of check valves in stand-by position at reactor pressure and operating by gravity under different pressure conditions. With the introduction of several passive systems in the SBWR-600 design, such as the Isolation Condensers, Gravity Driven Cooling, and Suppression Pool Cooling System, the issue of reliability of check valves in these systems is actual. Some critical aspects for study in connection with check valves are: What is the reliability of a check valve in a system at reactor pressure, to open on demand; what is the reliability of a check valve in a system at low pressure (gravity), to open on demand; what is the reliability of a check valve to open/close when the stand-by check wave is at zero differential pressure. The plant experience with check valves in a few essential safety systems is described and a brief introduction will be made about the application of check valves in the design of the new generation reactors is given. (author). 6 figs, 1 tab.

  2. NRC perspective and experience on valve testing

    International Nuclear Information System (INIS)

    Eapen, P.K.

    1990-01-01

    Testing of safety related valves is one of the major activities at commercial nuclear power plants. In addition to Technical Specification, valve testing is required in 10 CFR 50.55a and 10 CFR 50 Appendix J. NRC inspectors (both resident and specialists) spend a considerable amount of time in following the valve test activities as part of their routine business. In the past, depending on a licensee's organizational structure, a valve could be tested more than three times to verify conformance with Technical Specifications, 10 CFR 50.55a, and 10 CFR 50 Appendix J. The regulatory reviewers were isolated from each other. Licensee test personnel were also not communicating among themselves. As a result, NRC inspectors found that certain valves in the IST program were inadequately tested. The typical licensee response was to say that this valve is exempted from testing under Appendix J. Others would say that the technical specification does not require fast closure of a valve in question. In addition to the above, the inspectors had to deal with exemption requests that were not dispositioned by the NRC. In the seventies there was a gentlemen's agreement to allow the licensee to do the testing in accordance with the exception, without waiting for the NRC approval. Needless to say when the new NRC inspection procedure was issued in March 1989 for implementation, the Regional inspectors had extremely difficult time to cope with the gray areas of valve testing. In August 1987, NRC Region I was reorganized and the special test program section was established to perform inspections in the IST area. This section was chartered to optimize resources and develop a meaningful inspection plan. The perspectives and insights used in the development of a detailed inspection plan is discussed below

  3. One-way optical transmission in silicon photonic crystal heterojunction with circular and square scatterers

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Dan, E-mail: liudanhu725@126.com [School of Physics and Mechanical & Electrical Engineering, Hubei University of Education, Wuhan, 430205 (China); Hu, Sen [School of Physics and Mechanical & Electrical Engineering, Hubei University of Education, Wuhan, 430205 (China); Gao, Yihua [Wuhan National Laboratory for Optoelectronics (WNLO), School of Physics, Huazhong University of Science and Technology (HUST), Wuhan, 430074 (China)

    2017-07-12

    A 2D orthogonal square-lattice photonic crystal (PC) heterojunction consisting of circular and square air holes in silicon is presented. Band structures are calculated using the plane wave expansion method, and the transmission properties are investigated by the finite-different time-domain simulations. Thanks to the higher diffraction orders excited when the circular and square holes are interlaced along the interface, one-way transmission phenomena can exist within wide frequency regions. The higher order diffraction is further enhanced through two different interface optimization designs proposed by modifying the PC structure of the hetero-interface. An orthogonal PC heterojunction for wide-band and efficient one-way transmission is constructed, and the maximum transmissivity is up to 78%. - Highlights: • Photonic crystal heterojunction with circular and square scatterers is first studied. • One-way transmission efficiency is closely related to the hetero-interface. • Wide-band and efficient one-way transmission is realized.

  4. Door valve for fuel handling path

    International Nuclear Information System (INIS)

    Makishima, Katsuhiko.

    1969-01-01

    A door valve is provided which seals cover gas from a liquid metal cooled reactor without leakage therefrom. A threaded shaft is screwed into a heavy box press which is packed with lead. The shaft is adapted to be rotated by an electric motor or a manually operated wheel which is disposed outside of the door valve. A valve plate is suspended from the box press by four guide wheels mounted thereon. The guide wheels are fitted into inclined guide grooves formed at the valve plate and into grooved formed in the inner wall of a valve casing. A locking ball is provided at each side of the valve plate. In operation the shaft rotates and travels to permit the box press and the valve plate to move into the door valve casing, thus releasing the locking balls. The valve plate does not contact the bottom of the casing. When the box press reaches the home position, the valve plate is carried on the valve opening, and the box press presses the valve plate to increase the tightness. The valve plate does not suffer wear as it does not slide over other parts. (Yamaguchi, T.)

  5. Fluid-structure interaction analysis of the flow through a stenotic aortic valve

    Science.gov (United States)

    Maleki, Hoda; Labrosse, Michel R.; Durand, Louis-Gilles; Kadem, Lyes

    2009-11-01

    In Europe and North America, aortic stenosis (AS) is the most frequent valvular heart disease and cardiovascular disease after systemic hypertension and coronary artery disease. Understanding blood flow through an aortic stenosis and developing new accurate non-invasive diagnostic parameters is, therefore, of primarily importance. However, simulating such flows is highly challenging. In this study, we considered the interaction between blood flow and the valve leaflets and compared the results obtained in healthy valves with stenotic ones. One effective method to model the interaction between the fluid and the structure is to use Arbitrary Lagrangian-Eulerian (ALE) approach. Our two-dimensional model includes appropriate nonlinear and anisotropic materials. It is loaded during the systolic phase by applying pressure curves to the fluid domain at the inflow. For modeling the calcified stenotic valve, calcium will be added on the aortic side of valve leaflets. Such simulations allow us to determine the effective orifice area of the valve, one of the main parameters used clinically to evaluate the severity of an AS, and to correlate it with changes in the structure of the leaflets.

  6. Anesthetic Management and Complications of Percutaneous Aortic Valve Implantation

    Directory of Open Access Journals (Sweden)

    Tailur Alberto Grando

    2013-05-01

    Full Text Available Background and objective: Aortic stenosis is a highly prevalent and life-threatening disease. In elderly patients with comorbidities, percutaneous valve implantation is an option. The aim of the study was to describe the anesthetic management and complications of general anesthesia Method: Case series with 30-day and 24-month follow-ups after implantation of the CoreValve device performed at the Institute of Cardiology/University Foundation of Cardiology between December 2008 and January 2012. The patients underwent general anesthesia monitored with mean arterial pressure (PAM, electrocardiogram (ECG, pulse oximetry, capnography, transesophageal echocardiography, thermometry, and transvenous pacemaker. Results: Twenty-eight patients, mean age 82.46 years, 20.98% mean EuroSCORE, functional class III/IV, successfully underwent valve implantation. Nine patients required permanent pacemaker implantation. During follow-up, two patients died: one during surgery due to LV perforation and the other on the third day of unknown causes. At 24 months, one patient diagnosed with multiple myeloma died. This anesthetic technique proved to be safe. Conclusion: The initial experience with percutaneous aortic valve implantation under general anesthesia has proven to be safe and effective, with no significant anesthetic complications during this procedure. Keywords: Aesthesia, General, Cardiac Surgical Procedures, Aortic Valve Stenosis, Aged.

  7. Midterm Results of Aortic Valve Replacement with Cryopreserved Homografts

    Directory of Open Access Journals (Sweden)

    Emre Özker

    2012-06-01

    Full Text Available Objective: The aim of this study was to analyze the midterm clinical results of aortic valve replacement with cryopreserved homografts.Materials and Methods: Aortic valve replacement was performed in 40 patients with cryopreserved homograft. The indications were aortic valve endocarditis in 20 patients (50%, truncus arteriosus in 6 patients (15%, and re-stenosis or regurtitation after aortic valve reconstruction in 14 (35% patients. The valve sizes ranged from 10 to 27mm. A full root replacement technique was used for homograft replacement in all patients.Results: The 30-day postoperative mortality rate was 12.5% (5 patients. There were four late deaths. Only one of them was related to cardiac events. Overall mortality was 22.5%. Thirty-three patients were followed up for 67±26 months. Two patients needed reoperation due to aortic aneurysm caused by endocarditis. The mean transvalvular gradient significantly decreased after valve replacement (p<0.003. The last follow up showed that the 27 (82% patients had a normal left ventricular function.Conclusion: Cryopreserved homografts are safe alternatives to mechanical valves that can be used when there are proper indications. Although it has a high perioperative mortality rate, cryopreserved homograft implantation is an alternative for valve replacement, particularly in younger patients and for complex surgical problems such as endocarditis that must be minimalized.

  8. Characterization of a bioprosthetic bicuspid venous valve hemodynamics: implications for mechanism of valve dynamics.

    Science.gov (United States)

    Tien, W-H; Chen, H Y; Berwick, Z C; Krieger, J; Chambers, S; Dabiri, D; Kassab, G S

    2014-10-01

    Chronic venous insufficiency (CVI) of the lower extremities is a common clinical problem. Although bioprosthetic valves have been proposed to treat severe reflux, clinical success has been limited due to thrombosis and neointima overgrowth of the leaflets that is, in part, related to the hemodynamics of the valve. A bioprosthetic valve that mimics native valve hemodynamics is essential. A computational model of the prosthetic valve based on realistic geometry and mechanical properties was developed to simulate the interaction of valve structure (fluid-structure interaction, FSI) with the surrounding flow. The simulation results were validated by experiments of a bioprosthetic bicuspid venous valve using particle image velocimetry (PIV) with high spatial and temporal resolution in a pulse duplicator (PD). Flow velocity fields surrounding the valve leaflets were calculated from PIV measurements and comparisons to the FSI simulation results were made. Both the spatial and temporal results of the simulations and experiments were in agreement. The FSI prediction of the transition point from equilibrium phase to valve-closing phase had a 7% delay compared to the PD measurements, while the PIV measurements matched the PD exactly. FSI predictions of reversed flow were within 10% compared to PD measurements. Stagnation or stasis regions were observed in both simulations and experiments. The pressure differential across the valve and associated forces on the leaflets from simulations showed the valve mechanism to be pressure driven. The flow velocity simulations were highly consistent with the experimental results. The FSI simulation and force analysis showed that the valve closure mechanism is pressure driven under the test conditions. FSI simulation and PIV measurements demonstrated that the flow behind the leaflet was mostly stagnant and a potential source for thrombosis. The validated FSI simulations should enable future valve design optimizations that are needed for

  9. In-situ hot corrosion testing of candidate materials for exhaust valve spindles

    DEFF Research Database (Denmark)

    Bihlet, Uffe; Hoeg, Harro A.; Dahl, Kristian Vinter

    2011-01-01

    The two stroke diesel engine has been continually optimized since its invention more than a century ago. One of the ways to increase fuel efficiency further is to increase the compression ratio, and thereby the temperature in the combustion chamber. Because of this, and the composition of the fuel...... used, exhaust valve spindles in marine diesel engines are subjected to high temperatures and stresses as well as molten salt induced corrosion. To investigate candidate materials for future designs which will involve the HIP process, a spindle with Ni superalloy material samples inserted in a HIPd Ni49...

  10. Cryogenic Cam Butterfly Valve

    Science.gov (United States)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  11. Study of the one-way speed of light anisotropy with particle beams

    Energy Technology Data Exchange (ETDEWEB)

    Wojtsekhowski, Bogdan B. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2017-04-01

    Concepts of high precision studies of the one-way speed of light anisotropy are discussed. The high energy particle beam allows measurement of a one-way speed of light anisotropy (SOLA) via analysis of the beam momentum variation with sidereal phase without the use of synchronized clocks. High precision beam position monitors could provide accurate monitoring of the beam orbit and determination of the particle beam momentum with relative accuracy on the level of 10^-10, which corresponds to a limit on SOLA of 10^-18 with existing storage rings. A few additional versions of the experiment are also presented.

  12. Small valve area index: its influence on early mortality after mitral valve replacement

    NARCIS (Netherlands)

    Yazdanbakhsh, A. P.; van den Brink, R. B.; Dekker, Egbert; de Mol, B. A.

    2000-01-01

    OBJECTIVE: To test the hypothesis that mitral valve prosthesis-patient mismatch increases postoperative mortality. METHODS AND RESULTS: The effect of mitral valve prosthesis-patient mismatch on survival in a cohort of consecutive patients after mitral valve replacement with a mechanical prosthesis

  13. Study of typical nuclear containment purge valves in an accident environment

    International Nuclear Information System (INIS)

    Watkins, J.C.; Steele, R. Jr.; Hill, R.C.; DeWall, K.G.

    1986-08-01

    This report presents the results of the containment purge and vent valve test program, conducted under the sponsorship of the United States Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research. The test program investigated butterfly valve operability and leak integrity under light-water-reactor design basis and severe accident conditions. Three nuclear-designed butterfly valves typical of those used in domestic nuclear power plant containment purge and vent applications were tested. For a comparison of response, two valve of the same size with differing internal designs were tested. For extrapolation insights, a larger-sized valve similar to one of the smaller valves was also tested. Dynamic flow tests were performed over the range of design basis accident pressures. Leak integrity testing was also performed at both design basis and severe accident temperatures and pressures. The valve experiments were performed with various piping configurations and valve orientations to the flow to simulate the various installation options in field applications. Testing was also performed in a standard ANSI test section

  14. Dynamic load effects on gate valve operability

    International Nuclear Information System (INIS)

    Steele, R. Jr.; MacDonald, P.E.; Arendts, J.G.

    1986-01-01

    The Idaho National Engineering Laboratory (INEL) participated in an internationally sponsored seismic research program conducted at the decommissioned Heissdampfreaktor (HDR) located in the Federal Republic of Germany. An existing piping system was modified by installation of an 8-in., naturally aged, motor-operated gate valve from a US nuclear power plant and a piping support system of US design. Six other piping support systems of varying flexibility from stiff to flexible were also installed at various times during the tests. Additional valve loadings included internal hydraulic loads and, during one block of tests, elevated temperature. The operability and integrity of the aged gate valve and the dynamic response of the various piping support system were measured during 25 representative seismic events

  15. Non-reciprocity and topology in optics: one-way road for light via surface magnon polariton.

    Science.gov (United States)

    Ochiai, Tetsuyuki

    2015-02-01

    We show how non-reciprocity and topology are used to construct an optical one-way waveguide in the Voigt geometry. First, we present a traditional approach of the one-way waveguide of light using surface polaritons under a static magnetic field. Second, we explain a recent discovery of a topological approach using photonic crystals with the magneto-optical coupling. Third, we present a combination of the two approaches, toward a broadband one-way waveguide in the microwave range.

  16. Guideline for the acquisition and preparation of conventional and endobronchial ultrasound-guided transbronchial needle aspiration specimens for the diagnosis and molecular testing of patients with known or suspected lung cancer

    NARCIS (Netherlands)

    Heijden, E. van der; Casal, R.F.; Trisolini, R.; Steinfort, D.P.; Hwangbo, B.; Nakajima, T.; Guldhammer-Skov, B.; Rossi, G.; Ferretti, M.; Herth, F.F.; Yung, R.; Krasnik, M.

    2014-01-01

    RATIONALE: Conventional transbronchial needle aspiration (TBNA) and endobronchial ultrasound (EBUS)-TBNA are widely accepted tools for the diagnosis and staging of lung cancer and the initial procedure of choice for staging. Obtaining adequate specimens is key to provide a specific histologic and

  17. Björk-Shiley convexoconcave valves: susceptibility artifacts at brain MR imaging and mechanical valve fractures.

    Science.gov (United States)

    van Gorp, Maarten J; van der Graaf, Yolanda; de Mol, Bas A J M; Bakker, Chris J G; Witkamp, Theo D; Ramos, Lino M P; Mali, Willem P T M

    2004-03-01

    To assess the relationship between heart valve history and susceptibility artifacts at magnetic resonance (MR) imaging of the brain in patients with Björk-Shiley convexoconcave (BSCC) valves. MR images of the brain were obtained in 58 patients with prosthetic heart valves: 20 patients had BSCC valve replacements, and 38 had other types of heart valves. Two experienced neuroradiologists determined the presence or absence of susceptibility artifacts in a consensus reading. Artifacts were defined as characteristic black spots that were visible on T2*-weighted gradient-echo MR images. The statuses of the 20 explanted BSCC valves-specifically, whether they were intact or had an outlet strut fracture (OSF) or a single-leg fracture (SLF)-had been determined earlier. Number of artifacts seen at brain MR imaging was correlated with explanted valve status, and differences were analyzed with nonparametric statistical tests. Significantly more patients with BSCC valves (17 [85%] of 20 patients) than patients with other types of prosthetic valves (18 [47%] of 38 patients) had susceptibility artifacts at MR imaging (P =.005). BSCC valve OSFs were associated with a significantly higher number of artifacts than were intact BSCC valves (P =.01). No significant relationship between SLF and number of artifacts was observed. Susceptibility artifacts at brain MR imaging are not restricted to patients with BSCC valves. These artifacts can be seen on images obtained in patients with various other types of fractured and intact prosthetic heart valves. Copyright RSNA, 2004

  18. Fully Soft 3D-Printed Electroactive Fluidic Valve for Soft Hydraulic Robots.

    Science.gov (United States)

    Zatopa, Alex; Walker, Steph; Menguc, Yigit

    2018-06-01

    Soft robots are designed to utilize their compliance and contortionistic abilities to both interact safely with their environment and move through it in ways a rigid robot cannot. To more completely achieve this, the robot should be made of as many soft components as possible. Here we present a completely soft hydraulic control valve consisting of a 3D-printed photopolymer body with electrorheological (ER) fluid as a working fluid and gallium-indium-tin liquid metal alloy as electrodes. This soft 3D-printed ER valve weighs less than 10 g and allows for onboard actuation control, furthering the goal of an entirely soft controllable robot. The soft ER valve pressure-holding capabilities were tested under unstrained conditions, cyclic valve activation, and the strained conditions of bending, twisting, stretching, and indentation. It was found that the max holding pressure of the valve when 5 kV was applied across the electrodes was 264 kPa, and that the holding pressure deviated less than 15% from the unstrained max holding pressure under all strain conditions except for indentation, which had a 60% max pressure increase. In addition, a soft octopus-like robot was designed, 3D printed, and assembled, and a soft ER valve was used to stop the fluid flow, build pressure in the robot, and actuate six tentacle-like soft bending actuators.

  19. A high performance magnetorheological valve with a meandering flow path

    International Nuclear Information System (INIS)

    Imaduddin, Fitrian; Amri Mazlan, Saiful; Azizi Abdul Rahman, Mohd; Zamzuri, Hairi; Ubaidillah; Ichwan, Burhanuddin

    2014-01-01

    The huge developments in the field of magnetorheological (MR) fluid-based devices will have a great influence on the future of mechatronic applications due to the ease of interfacing between electronic controls and the mechanical components that they provide. Among various MR fluid-based devices, an MR valve would be particularly significant for the development of other devices, if it could be successfully achieved. One of the most challenging obstacles to MR valve development is the difficulty of achieving device miniaturization while, at the same time, improving the achievable performance. This study demonstrates a novel design for an MR valve, using the meandering flow path approach in order to increase the effective area so that the MR fluid can be regulated within a small-sized valve. The meandering flow path is formed by combining multiple annular, radial and orifice flow channels. In order to analyze the valve performance, a mathematical model of the proposed MR valve is derived and combined with numerical simulation using the finite element method, with the intention of predicting the achievable pressure drop that can be generated by the valve. The predicted MR valve performances are then experimentally evaluated using an oscillation-disturbed bypass hydraulic cylinder. The simulation results show that the proposed MR valve design could yield substantial pressure drop improvement, which is confirmed by the experiment

  20. Idiopathic mitral valve prolapse with tricuspid, aortic and pulmonary valve involvement: An autopsy case report

    Directory of Open Access Journals (Sweden)

    Heena M Desai

    2015-01-01

    Full Text Available Mitral valve prolapse (MVP is usually asymptomatic, but can be associated with complications such as infective endocarditis, mitral regurgitation, thromboembolism and sudden cardiac death. It has been very rarely reported to occur in association with other valvular involvement. A 55-year-old male patient was brought dead and at autopsy the mitral valve orifice was stenotic and the leaflets were enlarged, myxoid and bulging suggestive of MVP and chordae tendinae were thickened, stretched and elongated. Similar changes were seen in the tricuspid valve. The pulmonary and aortic valves also showed myxomatous degeneration of their cusps. Myxomatous degeneration is the most common cause of MVP and it can be associated with involvement of the other valves. Concomitant involvement of the aortic valve has been reported, however it is very rare and simultaneous involvement of the pulmonary valve has not been reported in the literature so far. We report a case of MVP associated with myxomatous degeneration of the tricuspid, pulmonary and aortic valves.

  1. Lung volume reduction for emphysema.

    Science.gov (United States)

    Shah, Pallav L; Herth, Felix J; van Geffen, Wouter H; Deslee, Gaetan; Slebos, Dirk-Jan

    2017-02-01

    Advanced emphysema is a lung disease in which alveolar capillary units are destroyed and supporting tissue is lost. The combined effect of reduced gas exchange and changes in airway dynamics impairs expiratory airflow and leads to progressive air trapping. Pharmacological therapies have limited effects. Surgical resection of the most destroyed sections of the lung can improve pulmonary function and exercise capacity but its benefit is tempered by significant morbidity. This issue stimulated a search for novel approaches to lung volume reduction. Alternative minimally invasive approaches using bronchoscopic techniques including valves, coils, vapour thermal ablation, and sclerosant agents have been at the forefront of these developments. Insertion of endobronchial valves in selected patients could have benefits that are comparable with lung volume reduction surgery. Endobronchial coils might have a role in the treatment of patients with emphysema with severe hyperinflation and less parenchymal destruction. Use of vapour thermal energy or a sclerosant might allow focal treatment but the unpredictability of the inflammatory response limits their current use. In this Review, we aim to summarise clinical trial evidence on lung volume reduction and provide guidance on patient selection for available therapies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Non-reciprocity and topology in optics: one-way road for light via surface magnon polariton

    Science.gov (United States)

    Ochiai, Tetsuyuki

    2015-01-01

    We show how non-reciprocity and topology are used to construct an optical one-way waveguide in the Voigt geometry. First, we present a traditional approach of the one-way waveguide of light using surface polaritons under a static magnetic field. Second, we explain a recent discovery of a topological approach using photonic crystals with the magneto-optical coupling. Third, we present a combination of the two approaches, toward a broadband one-way waveguide in the microwave range. PMID:27877739

  3. One way quantum repeaters with quantum Reed-Solomon codes

    OpenAIRE

    Muralidharan, Sreraman; Zou, Chang-Ling; Li, Linshu; Jiang, Liang

    2018-01-01

    We show that quantum Reed-Solomon codes constructed from classical Reed-Solomon codes can approach the capacity on the quantum erasure channel of $d$-level systems for large dimension $d$. We study the performance of one-way quantum repeaters with these codes and obtain a significant improvement in key generation rate compared to previously investigated encoding schemes with quantum parity codes and quantum polynomial codes. We also compare the three generation of quantum repeaters using quan...

  4. One-way EPR steering and genuine multipartite EPR steering

    Science.gov (United States)

    He, Qiongyi; Reid, Margaret D.

    2012-11-01

    We propose criteria and experimental strategies to realise the Einstein-Podolsky-Rosen (EPR) steering nonlocality. One-way steering can be obtained where there is asymmetry of thermal noise on each system. We also present EPR steering inequalities that act as signatures and suggest how to optimise EPR correlations in specific schemes so that the genuine multipartite EPR steering nonlocality (EPR paradox) can also possibly be realised. The results presented here also apply to the spatially separated macroscopic atomic ensembles.

  5. Cobalt reduction of NSSS valve hardfacings for ALARA

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Joo Hak; Lee, Sang Sub [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-07-01

    This report informs NSSS designer that replacement of materials is one of the major means of ALARA implementation, and describes that NSSS valves with high-cobalt hardfacing are significant contributors to post-shutdown radiation fields caused by activation of cobalt-59 to cobalt-60. Generic procedures for implementing cobalt reduction programs for valves are presented. Discussions are presented of the general and specific design requirements for valve hardfacing in nuclear service. The nuclear safety issues involved with changing valve hardfacing materials are discussed. The common methods used to deposit hardfacing materials are described together with an explanation of the wear measurements. Wear resistance, corrosion resistance, friction coefficient, and mechanical properties of candidate hardfacing alloys are given. World-wide nuclear utility experience with cobalt-free hardfacing alloys is described. The use of low-cobalt or cobalt-free alloys in other nuclear plant components is described. 17 figs., 38 tabs., 18 refs. (Author).

  6. Cobalt reduction of NSSS valve hardfacings for ALARA

    International Nuclear Information System (INIS)

    Kim, Joo Hak; Lee, Sang Sub

    1994-07-01

    This report informs NSSS designer that replacement of materials is one of the major means of ALARA implementation, and describes that NSSS valves with high-cobalt hardfacing are significant contributors to post-shutdown radiation fields caused by activation of cobalt-59 to cobalt-60. Generic procedures for implementing cobalt reduction programs for valves are presented. Discussions are presented of the general and specific design requirements for valve hardfacing in nuclear service. The nuclear safety issues involved with changing valve hardfacing materials are discussed. The common methods used to deposit hardfacing materials are described together with an explanation of the wear measurements. Wear resistance, corrosion resistance, friction coefficient, and mechanical properties of candidate hardfacing alloys are given. World-wide nuclear utility experience with cobalt-free hardfacing alloys is described. The use of low-cobalt or cobalt-free alloys in other nuclear plant components is described. 17 figs., 38 tabs., 18 refs. (Author)

  7. Automated control of the laser welding process of heart valve scaffolds

    Directory of Open Access Journals (Sweden)

    Weber Moritz

    2016-09-01

    Full Text Available Using the electrospinning process the geometry of a heart valve is not replicable by just one manufacturing process. To produce heart valve scaffolds the heart valve leaflets and the vessel have to be produced in separated spinning processes. For the final product of a heart valve they have to be mated afterwards. In this work an already existing three-axes laser was enhanced to laser weld those scaffolds. The automation control software is based on the robot operating system (ROS. The mechatronically control is done by an Arduino Mega. A graphical user interface (GUI is written with Python and Kivy.

  8. Impact of bicuspid aortic valve on complications and death in infective endocarditis of native aortic valves.

    Science.gov (United States)

    Kahveci, Gokhan; Bayrak, Fatih; Pala, Selcuk; Mutlu, Bulent

    2009-01-01

    We retrospectively investigated the impact of bicuspid aortic valve on the prognosis of patients who had definite infective endocarditis of the native aortic valve.Of 51 patients, a bicuspid aortic valve was present in 22 (43%); the other 29 had tricuspid aortic valves. On average, the patients who had bicuspid valves were younger than those who had tricuspid valves. Patients with a tricuspid valve had larger left atrial diameters and were more likely to have severe mitral regurgitation.Periannular complications, which we detected in 19 patients (37%), were much more common in the patients who had a bicuspid valve (64% vs 17%, P = 0.001). The presence of a bicuspid valve was the only significant independent predictor of periannular complications. The in-hospital mortality rate in the bicuspid group was lower than that in the tricuspid group; however, this figure did not reach statistical significance (9% vs 24%, P = 0.15). In multivariate analysis, left atrial diameter was the only independent predictor associated with an increased risk of death (hazard ratio, 2.19; 95% confidence interval, 1.1-4.5; P = 0.031).In our study, patients with infective endocarditis in a bicuspid aortic valve were younger and had a higher incidence of periannular complications. Although a worse prognosis has been reported previously, we found that infective endocarditis in a native bicuspid aortic valve is not likely to increase the risk of death in comparison with infective endocarditis in native tricuspid aortic valves.

  9. The Role of Airway and Endobronchial Ultrasound in Perioperative Medicine

    Directory of Open Access Journals (Sweden)

    Jiri Votruba

    2015-01-01

    Full Text Available Recent years have witnessed an increased use of ultrasound in evaluation of the airway and the lower parts of the respiratory system. Ultrasound examination is fast and reliable and can be performed at the bedside and does not carry the risk of exposure to ionizing radiation. Apart from use in diagnostics it may also provide safe guidance for invasive and semi-invasive procedures. Ultrasound examination of the oral cavity structures, epiglottis, vocal cords, and subglottic space may help in the prediction of difficult intubation. Preoperative ultrasound may diagnose vocal cord palsy or deviation or stenosis of the trachea. Ultrasonography can also be used for confirmation of endotracheal tube, double-lumen tube, or laryngeal mask placement. This can be achieved by direct examination of the tube inside the trachea or by indirect methods evaluating lung movements. Postoperative airway ultrasound may reveal laryngeal pathology or subglottic oedema. Conventional ultrasound is a reliable real-time navigational tool for emergency cricothyrotomy or percutaneous dilational tracheostomy. Endobronchial ultrasound is a combination of bronchoscopy and ultrasonography and is used for preoperative examination of lung cancer and solitary pulmonary nodules. The method is also useful for real-time navigated biopsies of such pathological structures.

  10. Transient flow analysis of integrated valve opening process

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Xinming; Qin, Benke; Bo, Hanliang, E-mail: bohl@tsinghua.edu.cn; Xu, Xingxing

    2017-03-15

    Highlights: • The control rod hydraulic driving system (CRHDS) is a new type of built-in control rod drive technology and the integrated valve (IV) is the key control component. • The transient flow experiment induced by IV is conducted and the test results are analyzed to get its working mechanism. • The theoretical model of IV opening process is established and applied to get the changing rule of the transient flow characteristic parameters. - Abstract: The control rod hydraulic driving system (CRHDS) is a new type of built-in control rod drive technology and the IV is the key control component. The working principle of integrated valve (IV) is analyzed and the IV hydraulic experiment is conducted. There is transient flow phenomenon in the valve opening process. The theoretical model of IV opening process is established by the loop system control equations and boundary conditions. The valve opening boundary condition equation is established based on the IV three dimensional flow field analysis results and the dynamic analysis of the valve core movement. The model calculation results are in good agreement with the experimental results. On this basis, the model is used to analyze the transient flow under high temperature condition. The peak pressure head is consistent with the one under room temperature and the pressure fluctuation period is longer than the one under room temperature. Furthermore, the changing rule of pressure transients with the fluid and loop structure parameters is analyzed. The peak pressure increases with the flow rate and the peak pressure decreases with the increase of the valve opening time. The pressure fluctuation period increases with the loop pipe length and the fluctuation amplitude remains largely unchanged under different equilibrium pressure conditions. The research results lay the base for the vibration reduction analysis of the CRHDS.

  11. Valve microstructure and phylomineralogy of New Zealand chitons.

    Science.gov (United States)

    Peebles, B A; Smith, A M; Spencer, H G

    2017-03-01

    The microstructure and mineralogy of chiton valves has been largely ignored in the literature and only described in 29 species to date. Eight species: Acanthochitona zelandica, Notoplax violacea (Family Acanthochitonidae, Suborder Acanthochitonina, Order Chitonida), Chiton glaucus, Onithochiton neglectus, Sypharochiton spelliserpentis, Sypharochiton sinclairi (Family Chitonidae, Suborder, Chitonina, Order Chitonida), Ischnochiton maorianus (Family Ischnochitonidae, Suborder Chitonina, Order Chitonida), and Leptochiton inquinatus (Family Leptochitonidae, Suborder Lepidopleurina, Order Lepidopleurida) were collected from the Otago Peninsula, South Island, New Zealand. The valves of these chitons were analysed with X-ray diffractometry, Raman spectrometry, and Scanning Electron Micrography (SEM) to determine their mineralogy and microstructure. Both the XRD and Raman data show that the valves consisted solely of aragonite. The observed microstructures of the valves were complex, typically composed of four to seven sublayers, and varied among species. The dorsal layer, the tegmentum, of each species was granular and the ventral layer, the articulamentum, was predominately composed of a spherulitic sublayer, a crossed lamellar sublayer, and an acicular sublayer. The chitonids Sypharochiton pelliserpentis and S. sinclairi had the most complex microstructure layering with three crossed lamellar, two spherulitic sublayers, and a ventral acicular sublayer while the acanthochitonids Acanthochitona zelandica and Notoplax violacea as well as the ischnochitonid Ischnochiton maorianus had the simplest structure with one spherulitic, one crossed lamellar sublayer, and a ventral acicular sublayer. Terminal valves were less complex than intermediate valves and tended to be dominated by the crossed lamellar structure. The leptochitonid Leptochiton inquinatus generated a unique crossed lamellar sublayer different from the other analysed chitonids. Acanthochitona zelandica is the only

  12. Mitral Valve Prolapse

    Science.gov (United States)

    ... valve syndrome . What happens during MVP? Watch an animation of mitral valve prolapse When the heart pumps ( ... our brochures Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  13. Application of ceramics to the sliding seat of valve bridge; Valve bridge yodobu eno ceramics tekiyo

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, T; Ono, T [Mitsubishi Motors Corp., Tokyo (Japan)

    1997-10-01

    For use in the valve train, using an OHV (over head valve) configuration. of a 4 valve diesel engine for trucks and buses; we developed a valve bridge, a component of a valve train, with a ceramic head that is made of silicon nitride(Si3N4) in contact with a rocker arm in order to reduce cost and improve wear resistance for further diesel engine emissions regulations. In order to evaluate the effect of this valve bridge, RIG tests and durability tests on actual engines were carried out. 7 figs., 2 tabs.

  14. Transcatheter Mitral Valve-in-Ring Implantation

    LENUS (Irish Health Repository)

    Tanner, RE

    2018-05-01

    Failed surgical mitral valve repair using an annuloplasty ring has traditionally been treated with surgical valve replacement or repair1. For patients at high risk for repeat open heart surgery, placement of a trans-catheter aortic valve (i.e., TAVI valve) within the mitral ring (i.e., Mitral-Valve-in-Ring, MViR) has emerged as a novel alternative treatment strategy2-5 . We describe our experience of a failed mitral valve repair that was successfully treated with a TAVI valve delivered via the trans-septal approach, and summarise the data relating to this emerging treatment strategy.

  15. Space Vehicle Valve System

    Science.gov (United States)

    Kelley, Anthony R. (Inventor); Lindner, Jeffrey L. (Inventor)

    2014-01-01

    The present invention is a space vehicle valve system which controls the internal pressure of a space vehicle and the flow rate of purged gases at a given internal pressure and aperture site. A plurality of quasi-unique variable dimension peaked valve structures cover the purge apertures on a space vehicle. Interchangeable sheet guards configured to cover valve apertures on the peaked valve structure contain a pressure-activated surface on the inner surface. Sheet guards move outwardly from the peaked valve structure when in structural contact with a purge gas stream flowing through the apertures on the space vehicle. Changing the properties of the sheet guards changes the response of the sheet guards at a given internal pressure, providing control of the flow rate at a given aperture site.

  16. Bicuspid aortic valve demonstrated with multislice computed tomography - a case report

    International Nuclear Information System (INIS)

    Marzec, M.; Lasek, W.; Serafin, Z.; Laskowska, K.; Swiatkiewicz, I.; Kubica, J.

    2004-01-01

    Bicuspid aortic valve (BAV) is one of the most common congenital heart defects and often coexists with other congenital abnormalities of the heart and great vessels. A standard diagnostic technique for valve imaging is echocardiography. However, suboptimal images may cause a diagnostic problem, especially in obese patients, women and in case of significant valve calcifications. The paper reports a case of a 27-year-old male patient with recurrent chest pain, appearing regardless of exertion. Routine physical examination, laboratory tests and echocardiography were negative. Multislice computed tomography (MSCT) showed normal coronary arteries and bicuspid aortic valve. The diagnostics of bicuspid aortic valve and the diagnostic value of MSCT are discussed. MSCT seems to be an important point in cardiac diagnostic algorithms, being an alternative modality for MR in BAV imaging. The presented case emphasizes the potential of MSCT for the diagnostics of cardiac valve congenital diseases. (author)

  17. Traumatic tricuspid valve insufficiency. Experience in thirteen patients.

    Science.gov (United States)

    van Son, J A; Danielson, G K; Schaff, H V; Miller, F A

    1994-11-01

    From 1964 through June 1993, thirteen patients with traumatic tricuspid insufficiency were treated surgically; all were male, and the ages ranged from 17 to 64 years (median 39 years). The condition was associated with blunt chest trauma in all patients: motor vehicle accidents in twelve and an explosion of a tank of compressed air in one. The median duration between trauma and operation was 17 years (range 1 month to 37 years). Preoperatively, six patients were in sinus rhythm and seven were in atrial fibrillation. At operation, the right ventricular function appeared moderately to severely depressed in twelve patients. In twelve patients, the anterior leaflet was flail because of chordal rupture (n = 9), rupture of anterior papillary muscle (n = 3), or tear in the anterior leaflet (n = 1). In one patient, the septal leaflet was missing and in another it was retracted and adherent to the ventricular septum. In five patients the tricuspid valve was repaired and in eight it was replaced. In seven patients in the latter group, the chordae, papillary muscles, and/or tricuspid valve leaflet(s) were found to be in a contracted and atrophic state, precluding repair. No early or late deaths occurred. At follow-up extending to 26 years (median 12 years), 12 patients are in New York Heart Association class I and one patient is in class II. Nine patients were in sinus rhythm and four were in atrial fibrillation. Although our experience indicates that good functional results can still be achieved many years after the onset of traumatic tricuspid valve insufficiency, earlier diagnosis and surgical treatment should increase the feasibility of tricuspid valve insufficiency, earlier diagnosis and surgical treatment should increase the feasibility of tricuspid valve repair, prevent progressive deterioration of right ventricular function, and increase the possibility of maintaining late sinus rhythm in a greater number of patients.

  18. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    Transcatheter aortic valve implantation (TAVI) in severe aortic stenosis has proven to be a feasible and effective treatment modality for inoperable patients. Until now, neither aortic regurgitation nor degenerated bioprostheses has been an indication for TAVI. However, this article reports...... a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  19. Thermally induced pressure locking of gate valves: A survey of valve bonnet pressurization rates

    International Nuclear Information System (INIS)

    Ezekoye, L.I.; Moore, W.E.

    1996-01-01

    Closed, water filled gate valves run the risk of becoming pressurized due to heat input from the environment or from adjacent connected piping. Thermal pressurization of gate valve bonnets may lead to the valves failing to open on demand and can even induce structural failure of valves. This paper presents an analytical prediction of the pressurization rate of a closed pressure vessel subject to uniform heating which may be considered as an upper bound to the pressurization rate that may occur in the field. Then actual valve experiences described in the literature are reviewed to determine the expected pressurization rate in existing hardware designs. A statistical approach is applied to reconcile the differing pressurization rates reported in the literature and determine a rate that can be applied in valve evaluations. The limitations of the reconciled rate are discussed

  20. Histogram-based quantitative evaluation of endobronchial ultrasonography images of peripheral pulmonary lesion.

    Science.gov (United States)

    Morikawa, Kei; Kurimoto, Noriaki; Inoue, Takeo; Mineshita, Masamichi; Miyazawa, Teruomi

    2015-01-01

    Endobronchial ultrasonography using a guide sheath (EBUS-GS) is an increasingly common bronchoscopic technique, but currently, no methods have been established to quantitatively evaluate EBUS images of peripheral pulmonary lesions. The purpose of this study was to evaluate whether histogram data collected from EBUS-GS images can contribute to the diagnosis of lung cancer. Histogram-based analyses focusing on the brightness of EBUS images were retrospectively conducted: 60 patients (38 lung cancer; 22 inflammatory diseases), with clear EBUS images were included. For each patient, a 400-pixel region of interest was selected, typically located at a 3- to 5-mm radius from the probe, from recorded EBUS images during bronchoscopy. Histogram height, width, height/width ratio, standard deviation, kurtosis and skewness were investigated as diagnostic indicators. Median histogram height, width, height/width ratio and standard deviation were significantly different between lung cancer and benign lesions (all p histogram standard deviation. Histogram standard deviation appears to be the most useful characteristic for diagnosing lung cancer using EBUS images. © 2015 S. Karger AG, Basel.

  1. Colombian experience with transcatheter aortic valve implantation of medtronic CoreValve.

    Science.gov (United States)

    Dager, Antonio E; Nuis, Rutger-Jan; Caicedo, Bernardo; Fonseca, Jaime A; Arana, Camilo; Cruz, Lidsa; Benitez, Luis M; Nader, Carlos A; Duenas, Eduardo; de Marchena, Eduardo J; O'Neill, William W; de Jaegere, Peter P

    2012-01-01

    At our institutions, increasing numbers of aortic stenosis patients were not candidates for surgical aortic valve replacement. Accordingly, we initiated the Cali Colombian Transcatheter Aortic Valve Implantation (TAVI) program. From March 2008 through January 2011, 53 consecutive patients (mean age, 79 ± 6 yr; men, 58%) underwent TAVI with the Medtronic CoreValve System, and data were prospectively collected. Our study's endpoints conformed with Valve Academic Research Consortium recommendations. We report our clinical results.Predicted mortality rates were 25% (interquartile range, 17%-34%) according to logistic EuroSCORE and 6% (interquartile range, 3%-8%) according to the Society of Thoracic Surgeons score. The 30-day mortality rate was 9% (3 intraprocedural deaths, 5 total). The combined 30-day safety endpoint was 30% (major vascular sequelae, 23%; life-threatening bleeding, 12%; myocardial infarction, 4%; major stroke, 4%; and acute kidney injury [stage 3], 2%). Eight patients (15%) required post-implantation balloon dilation and 2 (4%) required valve-in-valve implantation, for a technical device success rate of 77%. Mean peak transvalvular gradient decreased from 74 ± 29 to 17 ± 8 mmHg and mean transvalvular gradient from 40 ± 17 to 8 ± 4 mmHg (both P=0.001). Moderate or severe aortic regurgitation decreased from 32% to 18% (P=0.12) and mitral regurgitation from 32% to 13% (P=0.002). The 1-year survival rate was 81%.We found that TAVI with the CoreValve prosthesis was safe and feasible, with sustained long-term results, for treating aortic stenosis in patients at excessive surgical risk; nonetheless, serious adverse events occurred in 30% of the patients.

  2. Traumatic Mitral Valve and Pericardial Injury

    Directory of Open Access Journals (Sweden)

    Nissar Shaikh

    2013-01-01

    Full Text Available Cardiac injury after blunt trauma is common but underreported. Common cardiac trauma after the blunt chest injury (BCI is cardiac contusion; it is very rare to have cardiac valve injury. The mitral valve injury during chest trauma occurs when extreme pressure is applied at early systole during the isovolumic contraction between the closure of the mitral valve and the opening of the aortic valve. Traumatic mitral valve injury can involve valve leaflet, chordae tendineae, or papillary muscles. For the diagnosis of mitral valve injury, a high index of suspicion is required, as in polytrauma patients, other obvious severe injuries will divert the attention of the treating physician. Clinical picture of patients with mitral valve injury may vary from none to cardiogenic shock. The echocardiogram is the main diagnostic modality of mitral valve injuries. Patient’s clinical condition will dictate the timing and type of surgery or medical therapy. We report a case of mitral valve and pericardial injury in a polytrauma patient, successfully treated in our intensive care unit.

  3. A case of central type early stage lung cancer receiving 60Co high dose-rate postoperative endobronchial radiation

    International Nuclear Information System (INIS)

    Nakamori, Syouji; Kodama, Ken; Kurokawa, Eiji; Doi, Osamu; Terasawa, Toshio; Chatani, Masashi; Inoue, Toshihiko; Tateishi, Ryuhei

    1985-01-01

    Right middle-lower lobectomy and mediastinal lymph node dissection were performed for a case of central type early stage lung cancer. Tumor extended very closely to the line of incision margin of the resected specimen, appearing as carcinoma in situ. To inprove curativity, postoperative radiation therapy was performed with 60 Co high dose-rate endobronchial radiation by a remote afterloading system. A total dose of 40Gy was administered to the target area without any severe side effects. The patient is healthy and has no evidence of metastasis. This procedure is considered to be an effective treatment for postoperative lung cancer with possible residual malignancy. (author)

  4. Mechanisms of mechanical heart valve cavitation: investigation using a tilting disk valve model.

    Science.gov (United States)

    He, Z; Xi, B; Zhu, K; Hwang, N H

    2001-09-01

    The induction of mechanical heart valve (MHV) cavitation was investigated using a 27 mm Medtronic Hall (MH27) tilting disk valve. The MH27 valve was mounted in the mitral position of a simulating pulse flow system, and stroboscopic lighting used to visualize cavitation bubbles on the occluder inflow surface at the instant of valve closure. MHV cavitation was monitored using a digital camera with 0.04 mm/pixel resolution sufficient to render the tiny bubbles clearly visible on the computer monitor screen. Cavitation on MH27 valve was classified as five types according to the time, site and shape of the cavitation bubbles. Valve cavitation occurred at the instant of occluder impact with the valve seat at closing. The impact motion was subdivided into three temporal phases: (i) squeezing flow; (ii) elastic collision; and (iii) leaflet rebound. MHV cavitation caused by vortices was found to be initiated by the squeezing jet and/or by the transvalvular leakage jets. By using a tension wave which swept across the occluder surface immediately upon elastic impact, nuclei in the vortex core were expanded to form cavitation bubbles. Analysis of the shape and location of the cavitation bubbles permitted a better understanding of MHV cavitation mechanisms, based on the fluid dynamics of jet vortex and tension wave propagations.

  5. Fairchild Stratos Division's Type II prototype lockhopper valve: METC Prototype Test Valve No. F-1 prototype lockhopper valve-testing and development project. Static test report

    Energy Technology Data Exchange (ETDEWEB)

    Goff, D. R.; Cutright, R. L.; Griffith, R. A.; Loomis, R. B.; Maxfield, D. A.; Moritz, R. S.

    1981-10-01

    METC Prototype Test Valve No. F-1 is a hybrid design, based on a segmented ball termed a visor valve, developed and manufactured by Fairchild Stratos Division under contract to the Department of Energy. The valve uses a visor arm that rotates into position and then translates to seal. This valve conditionally completed static testing at METC with clean gas to pressures of 1600 psig and internal valve temperatures to 600/sup 0/F. External leakage was excessive due to leakage through the stuffing box, purge fittings, external bolts, and other assemblies. The stuffing box was repacked several times and redesigned midway through the testing, but external leakage was still excessive. Internal leakage through the seats, except for a few anomalies, was very low throughout the 2409 cycles of testing. As shown by the low internal leakage, the visor valve concept appears to have potential for lock-hopper valve applications. The problems that are present with METC Prototype Test Valve No. F-1 are in the seals, which are equivalent to the shaft and bonnet seals in standard valve designs. The operating conditions at these seals are well within the capabilities of available seal designs and materials. Further engineering and minor modifications should be able to resolve the problems identified during static testing.

  6. Prevalence of pannus formation after aortic valve replacement: clinical aspects and surgical management.

    Science.gov (United States)

    Sakamoto, Yoshimasa; Hashimoto, Kazuhiro; Okuyama, Hiroshi; Ishii, Shinichi; Shingo, Taguchi; Kagawa, Hiroshi

    2006-01-01

    Pannus formation after aortic valve replacement is not common, but obstruction due to chronic pannus is one of the most serious complications of valve replacement. The causes of pannus formation are still unknown and effective preventive methods have not been fully elucidated. We reviewed our clinical experience of all patients who underwent reoperation for prosthetic aortic valve obstruction due to pannus formation between 1973 and 2004. We compared the initial 18-year period of surgery, when the Björk-Shiley tilting-disk valve was used, and the subsequent 13-year period of surgery, when the St. Jude Medical valve was used. Seven of a total of 390 patients (1.8%) required reoperation for prosthetic aortic valve obstruction due to pannus formation. All seven patients were women; four patients underwent resection of the pannus and three patients needed replacement of the valve. The frequency of pannus formation in the early group was 2.4% (6/253), whereas it was 0.73% (1/137) in the late group (P Pannus was localized at the minor orifice of the Björk-Shiley valve in the early group and turbulent transvalvular blood flow was considered to be one of the important factors triggering its growth. We also consider that small bileaflet valves have the possibility of promoting pannus formation and that the implantation of a larger prosthesis can contribute to reducing the occurrence of pannus.

  7. Long-Term Results of Mitral Valve Repair

    Directory of Open Access Journals (Sweden)

    Francisco Diniz Affonso da Costa

    Full Text Available Abstract Introduction: Current guidelines state that patients with severe mitral regurgitation should be treated in reference centers with a high reparability rate, low mortality rate, and durable results. Objective: To analyze our global experience with the treatment of organic mitral regurgitation from various etiologies operated in a single center. Methods: We evaluated all surgically treated patients with organic mitral regurgitation from 2004-2017. Patients were evaluated clinically and by echocardiography every year. We determined early and late survival rates, valve related events and freedom from recurrent mitral regurgitation and tricuspid regurgitation. Valve failure was defined as any mitral regurgitation ≥ moderate degree or the need for reoperation for any reason. Results: Out of 133 patients with organic mitral regurgitation, 125 (93.9% were submitted to valve repair. Mean age was 57±15 years and 52 patients were males. The most common etiologies were degenerative disease (73 patients and rheumatic disease (34 patients. Early mortality was 2.4% and late survival was 84.3% at 10 years, which are similar to the age- and gender-matched general population. Only two patients developed severe mitral regurgitation, and both were reoperated (95.6% at 10 years. Freedom from mitral valve failure was 84.5% at 10 years, with no difference between degenerative and rheumatic valves. Overall, late ≥ moderate tricuspid regurgitation was present in 34% of the patients, being more common in the rheumatic ones. The use of tricuspid annuloplasty abolished this complication. Conclusion: We have demonstrated that mitral regurgitation due to organic mitral valve disease from various etiologies can be surgically treated with a high repair rate, low early mortality and long-term survival that are comparable to the matched general population. Concomitant treatment of atrial fibrillation and tricuspid valve may be important adjuncts to optimize long

  8. Assessment of diagnostic methods for determining degradation of check valves

    International Nuclear Information System (INIS)

    Haynes, H.D.; Farmer, W.S.

    1992-01-01

    The Oak Ridge National Laboratory (ORNL) has carried out a comprehensive aging assessment of check valves in support of the Nuclear Plant Aging Research (NPAR) program. This paper provides a summary of the ORNL check valve aging assessment with emphasis on the identification, evaluation, and application of check valve monitoring methods and techniques. Several check valve monitoring methods are described and compared. These methods include: acoustic emission monitoring, ultrasonic inspection, magnetic flux signature analysis (MFSA), external magnetics. These diagnostic technologies were shown to be useful in determining check valve condition (e.g., disc position, disc motion, and seat leakage), although none of the methods was by itself, successful in monitoring all three condition indicators. The combination of acoustic emission with either ultrasonics or one of the magnetic technologies, however, yields a monitoring system that succeeds in providing the sensitivity to detect all major check valve operating conditions. Other areas covered in the paper include descriptions of relevant regulatory issues, utility group activities, and interactions ORNL has had with outside organizations for the purpose of disseminating research results

  9. Preoperative computer tomography evaluation in transcatheter aortic valve replacement (TAVI)

    International Nuclear Information System (INIS)

    Groudeva, V.; Stoynova, V.; Trendafilova, D.; Dzhorgova, Y.; Nachev, G.

    2014-01-01

    Transcatheter aortic valve replacement is rapidly emerging technique alternative to surgery in high risk patients. Imaging and especially computer tomography is important in preoperative assessment of the aortic ring and the prosthetic valve choice. The aim of this study is to share authors initial experience in CT assessment of the aortic ring prior to Transcatheter aortic valve replacement. 49 patients (mean age 76,55) underwent 320 rows MDCT (Acquilon One) prior TAVI. Protocol involved scanning from thoracic inlet to common femoral arteries. Aortic root size, aortic diameter at the level of coronary sinuses and the sinotubular junction and distance to coronary ostia were evaluated on a Vitrea work station. MDCT established maximal aortic ring diameter from 18 to 31 mm mean 25,04 mm while the lesser rate was from 16 to 21 mm. Accordingly positioned prostheses were in 34,75% No. 23, in 49% - No. 26 and in16,3% - No. 29. MDCT is crucial in aortic valve assessment prior to TAVI in experienced hands and multidisciplinary team. (authors) Key words: TRANSCATHETER AORTIC VALVE REPLACEMENT (TAVI). MDCT AORTIC VALVE ASSESSMENT

  10. Spin Valve Systems for Angle Sensor Applications

    OpenAIRE

    Johnson, Andrew

    2004-01-01

    A contact-less sensor with the ability to measure over a 360° range has been long sought after in the automotive industry. Such a sensor could be realized by utilizing the angle dependence of the Giant Magneto Resistance (GMR) Effect in a special type of magnetic multilayer called a spin valve arranged in a wheatstone bridge circuit [Spo96]. A spin valve consists of two ferromagnetic layers separated by nonmagnetic spacer layer where the magnetization of one of the ferromagnetic layers is pin...

  11. Simulant Development for Hanford Tank Farms Double Valve Isolation (DVI) Valves Testing

    Energy Technology Data Exchange (ETDEWEB)

    Wells, Beric E.

    2012-12-21

    Leakage testing of a representative sample of the safety-significant isolation valves for Double Valve Isolation (DVI) in an environment that simulates the abrasive characteristics of the Hanford Tank Farms Waste Transfer System during waste feed delivery to the Waste Treatment and Immobilization Plant (WTP) is to be conducted. The testing will consist of periodic leak performed on the DVI valves after prescribed numbers of valve cycles (open and close) in a simulated environment representative of the abrasive properties of the waste and the Waste Transfer System. The valve operations include exposure to cycling conditions that include gravity drain and flush operation following slurry transfer. The simulant test will establish the performance characteristics and verify compliance with the Documented Safety Analysis. Proper simulant development is essential to ensure that the critical process streams characteristics are represented, National Research Council report “Advice on the Department of Energy's Cleanup Technology Roadmap: Gaps and Bridges”

  12. Combined PCI and minimally invasive heart valve surgery for high-risk patients.

    Science.gov (United States)

    Umakanthan, Ramanan; Leacche, Marzia; Petracek, Michael R; Zhao, David X; Byrne, John G

    2009-12-01

    Combined coronary artery valvular heart disease is a major cause of morbidity and mortality in the adult patient population. The standard treatment for such disease has been open heart surgery in which coronary artery bypass grafting (CABG) is performed concurrently with valve surgery using a median sternotomy and cardiopulmonary bypass. With the increasing complexity of patients referred to surgery, some patients may prove to be poor surgical candidates for combined valve and CABG surgery. In certain selected patients who fall into this category, valve surgery and percutaneous coronary intervention (PCI) have been considered a feasible alternative. Conventionally, valve surgery is performed in the cardiac surgical operating room, whereas PCI is carried out in the cardiac catheterization laboratory. Separation of these two procedural suites has presented a logistic limitation because it impedes the concomitant performance of both procedures in one setting. Hence, PCI and valve surgery usually have been performed as a "two-stage" procedure in two different operative suites, with the procedures being separated by hours, days, or weeks. Technologic advancements have made possible the construction of a "hybrid" procedural suite that combines the facilities of a cardiac surgical operating room with those of a cardiac catheterization laboratory. This design has enabled the concept of "one-stage" or "one-stop" PCI and valve surgery, allowing both procedures to be performed in a hybrid suite in one setting, separated by minutes. The advantages of such a method could prove to be multifold by enabling a less invasive surgical approach and improving logistics, patient satisfaction, and outcomes in selected patients.

  13. Stent valve implantation in conventional redo aortic valve surgery to prevent patient-prosthesis mismatch.

    Science.gov (United States)

    Ferrari, Enrico; Franciosi, Giorgio; Clivio, Sara; Faletra, Francesco; Moccetti, Marco; Moccetti, Tiziano; Pedrazzini, Giovanni; Demertzis, Stefanos

    2017-03-01

    The goal was to show the technical details, feasibility and clinical results of balloon-expandable stent valve implantation in the aortic position during conventional redo open-heart surgery in selected obese patients with a small aortic prosthesis and severe patient-prosthesis mismatch. Two symptomatic overweight patients (body mass index of 31 and 38), each with a small aortic prosthesis (a 4-year-old, 21-mm Hancock II biological valve and a 29-year-old, 23-mm Duromedic mechanical valve), increased transvalvular gradients (59/31 and 74/44 mmHg) and a reduced indexed effective orifice area (0.50 and 0.43 cm 2 /m 2 ) underwent implantation of two 26-mm balloon-expandable Sapien 3 valves during standard on-pump redo valve surgery. Using full re-sternotomy, cardiopulmonary bypass and cardioplegic arrest, the two balloon-expandable stent valves were implanted under direct view using a standard aortotomy, after prosthesis removal and without annulus enlargement. Aortic cross-clamp times were 162 and 126 min; cardiopulmonary bypass times were 178 and 180 min; total surgical times were 360 and 318 min. At discharge, echocardiograms showed transvalvular peak and mean gradients of 13/9 and 23/13 mmHg and indexed effective orifice areas of 0.64 and 1.08 cm 2 /m 2 . The 3-month echocardiographic follow-up showed transvalvular peak and mean gradients of 18/9 and 19/11 mmHg and indexed effective orifice areas of 0.78 cm 2 /m 2 and 0.84 cm 2 /m 2 , with improved symptoms (New York Heart Association class 1). Implantation of a balloon-expandable stent valve during redo aortic valve surgery is feasible in selected cases and prevents patient-prosthesis mismatch in obese patients without need for aortic annulus enlargement. Moreover, in the case of stent valve degeneration, this approach permits additional valve-in-valve procedures with large stent valves and prevents re-redo surgery. © The Author 2016. Published by Oxford University Press on behalf of the

  14. A parsimonious model for the proportional control valve

    OpenAIRE

    Elmer, KF; Gentle, CR

    2001-01-01

    A generic non-linear dynamic model of a direct-acting electrohydraulic proportional solenoid valve is presented. The valve consists of two subsystems-s-a spool assembly and one or two unidirectional proportional solenoids. These two subsystems are modelled separately. The solenoid is modelled as a non-linear resistor-inductor combination, with inductance parameters that change with current. An innovative modelling method has been used to represent these components. The spool assembly is model...

  15. Bioprinting a cardiac valve.

    Science.gov (United States)

    Jana, Soumen; Lerman, Amir

    2015-12-01

    Heart valve tissue engineering could be a possible solution for the limitations of mechanical and biological prostheses, which are commonly used for heart valve replacement. In tissue engineering, cells are seeded into a 3-dimensional platform, termed the scaffold, to make the engineered tissue construct. However, mimicking the mechanical and spatial heterogeneity of a heart valve structure in a fabricated scaffold with uniform cell distribution is daunting when approached conventionally. Bioprinting is an emerging technique that can produce biological products containing matrix and cells, together or separately with morphological, structural and mechanical diversity. This advance increases the possibility of fabricating the structure of a heart valve in vitro and using it as a functional tissue construct for implantation. This review describes the use of bioprinting technology in heart valve tissue engineering. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Post-bronchoscopy fatal endobronchial hemorrhage in a woman with bronchopulmonary mucormycosis: a case report

    Directory of Open Access Journals (Sweden)

    La Licata Francesco

    2010-12-01

    Full Text Available Abstract Introduction During infection, Mucorales fungi invade major blood vessels, leading to extensive necrosis, and in cases of extensive pulmonary disease, bleeding into the lungs may occur. Case presentation We report an unexpected event of post-bronchoscopy fatal endobronchial hemorrhage in a 62-year-old HIV-negative Italian woman with well controlled diabetes mellitus who presented with diffuse cavitated pulmonary lesions. Fiberoptic bronchoscopy revealed bilateral obstruction of the segmental bronchi. Fatal massive bleeding occurred after standard biopsy procedures. Histologic examination showed that the hyphae were more deeply colored by hematoxylin-eosin (H&E than by other stains for fungi. Culture and autopsy confirmed bronchopulmonary mucormycosis. Conclusion Infection by Mucorales fungi should be considered in the diabetes population regardless of the degree of metabolic control. In these patients, particular caution should be taken during bronchoscopic procedures because of the greater friability of the fungal lesions.

  17. On-line valve monitoring at the Ormen Lange gas plant

    Energy Technology Data Exchange (ETDEWEB)

    Greenlees, R.; Hale, S. [Score Atlanta Inc., Kennesaw, Georgia (United States)

    2011-07-01

    The purpose of this presentation is to discuss replacing time and labor intensive nuclear outage activities with on line condition monitoring solutions, primarily the periodic verification of MOV functionality discussed in USNRC Generic Letter 96.05. This regulation requires that MOV age related performance degradations are properly identified and accounted for, causing utilities to have to retest valves periodically for the duration of the plants operating license. AECL designed CANDU reactors have a world class performance and safety record, with typical average annual capacity factors of 90%. The CANDU reactor design has the ability to refuel on line, as a result (a) it can be a challenge scheduling all required valve testing into limited duration outage work windows, (b) at multi unit sites, Unit 0 valves can be difficult to test because they are rarely ever out of service, (c) deuterium-oxide (heavy water) moderator is expensive to manufacture, as a result, effective through valve leakage monitoring is essential. These three factors alone make CANDU sites the most suitable candidates for on line valve monitoring systems. Nuclear industry regulations have been instrumental in the development of 'at the valve' diagnostic systems, but diagnostic testing has not typically been utilized to the same degree in other less regulated industries. However, that trend is changing, and the move toward valve diagnostics and condition monitoring has moved fastest in the offshore oil and gas industry on the Norwegian side of the North Sea. The Ormen Lange plant, located on Nyhamna Island on the west coast of Norway, operated by Shell, is one of the worlds most advanced gas processing plants. A stated maintenance goal for the plant is that 70% of the maintenance budget and spend should be based on the results of on line condition monitoring, utilizing monitoring systems equipped with switch sensing, strain gages, hydraulic and pneumatic pressure transducers and

  18. On-line valve monitoring at the Ormen Lange gas plant

    International Nuclear Information System (INIS)

    Greenlees, R.; Hale, S.

    2011-01-01

    The purpose of this presentation is to discuss replacing time and labor intensive nuclear outage activities with on line condition monitoring solutions, primarily the periodic verification of MOV functionality discussed in USNRC Generic Letter 96.05. This regulation requires that MOV age related performance degradations are properly identified and accounted for, causing utilities to have to retest valves periodically for the duration of the plants operating license. AECL designed CANDU reactors have a world class performance and safety record, with typical average annual capacity factors of 90%. The CANDU reactor design has the ability to refuel on line, as a result (a) it can be a challenge scheduling all required valve testing into limited duration outage work windows, (b) at multi unit sites, Unit 0 valves can be difficult to test because they are rarely ever out of service, (c) deuterium-oxide (heavy water) moderator is expensive to manufacture, as a result, effective through valve leakage monitoring is essential. These three factors alone make CANDU sites the most suitable candidates for on line valve monitoring systems. Nuclear industry regulations have been instrumental in the development of 'at the valve' diagnostic systems, but diagnostic testing has not typically been utilized to the same degree in other less regulated industries. However, that trend is changing, and the move toward valve diagnostics and condition monitoring has moved fastest in the offshore oil and gas industry on the Norwegian side of the North Sea. The Ormen Lange plant, located on Nyhamna Island on the west coast of Norway, operated by Shell, is one of the worlds most advanced gas processing plants. A stated maintenance goal for the plant is that 70% of the maintenance budget and spend should be based on the results of on line condition monitoring, utilizing monitoring systems equipped with switch sensing, strain gages, hydraulic and pneumatic pressure transducers and acoustic leakage

  19. Diseases of the Tricuspid Valve

    Science.gov (United States)

    ... stenosis. Tricuspid Regurgitation Tricuspid regurgitation is also called tricuspid insufficiency or tricuspid incompetence. It means there is a ... require valve surgery. Tags: heart valves , tricuspid incompetence , ... tricuspid regurgitation , tricuspid stenosis , valve disease Related Links ...

  20. Study on the Measurement of Valve Leak Rate Using Acoustic Emission Technology

    International Nuclear Information System (INIS)

    Lee, Sang-Guk; Park, Jong-Hyuck; Yoo, Keun-Bae; Lee, Sun-Ki; Hong, Sung-Yull

    2006-01-01

    This study is to estimate the feasibility of acoustic emission(AE) method for the internal leak from the valves. In this study, 4 inch ball water valve leak tests using three different leak path and various leak rates were performed in order to analyze AE properties when leaks arise in valve seat. As a result of leak test for specimens simulated valve seat, we conformed that leak sound amplitude increased in proportion to the increase of leak rate, and leak rates were plotted versus peak acoustic amplitudes recorded within those two narrow frequency bands on each spectrum plot. The resulting plots of leak rate versus peak AE amplitude were the primary basis for determining the feasibility of quantifying leak acoustically. The large amount of data attained also allowed a favorable investigation of the effects of different leak paths, leak rates, pressure differentials and AE sensors on the AE amplitude spectrum. From the experimental results, it was suggested that the AE method for monitoring of leak was feasible. This paper describes quantitative measurements of fluid valve leak rates by the analysis of AE. Experimental apparatus were fabricated to accept a variety of leaking water valves in order to determine what characteristics of AE signal change with leak rate. The data for each valve were generated by varying the leak rate and recording the time averaged amplitude of AE versus frequency. Leak rates were varied by modifying the valve seating surfaces in ways designed to simulate actual defects observed in service. Most of the data analysis involved plotting the leak rate versus signal amplitude at a specific frequency to determine how well the two variables correlate in terms of accuracy, resolution, and repeatability

  1. Numerical Analysis of Combined Valve Hydrodynamic Characteristics for Turbine System

    International Nuclear Information System (INIS)

    Bhowmik, P. K.; Shamim, J. A.; Gairola, A.; Arif, M.; Suh, Kune Y.

    2014-01-01

    Flow characteristic curves are plotted by calculating the ratio of the measured mass flow rate versus the theoretical mass flow rate. The flow characteristic curves are utilized to accurately test the performance of the control valve of turbine system to ensure the highest controllability and reliability of the power conversion system of large and small power plants. Turbine converts the kinetic energy of steam to mechanical energy of rotor blades in power conversion system. The electrical energy output from the generator of which the rotor is coupled with that of the turbine depends on the rotation velocity of the turbine bucket. The rotation velocity is proportional to the mass flow rate (steam or gas) to the turbine through valves and nozzles. The turbine comprises fast acting governing control valves and stop valves acting against the seat in the flow passage in the closed position. The turbine control valve regulates the mass flow rate entering the first nozzle of a turbine. The main function of stop valve is to close the fluid inlet rapidly in response to a fast close signal to swiftly cut off the flow through the valve inlet. Both these valves contribute attractively to improvement of the power system transient stability as well. To improve the efficiency of power conversion system many investigation have been done by researcher by focusing on the cycle layout or working fluid or by improving the flow path of the working fluid. The main focus is to find out the best option for combined cycle power plant by analyzing four different cycle configuration. Next research phase focused on different way to enhance the cycle efficiency. As the electrical power output from the generator is proportional to the mass flow rate to the turbine through the valve, it should preferably operate linearly. In reality, however, the valve has the various flow characteristics pursuant to the stem lift. Thus, the flow characteristic and control performance are needed to be designed

  2. Numerical Analysis of Combined Valve Hydrodynamic Characteristics for Turbine System

    Energy Technology Data Exchange (ETDEWEB)

    Bhowmik, P. K.; Shamim, J. A.; Gairola, A.; Arif, M.; Suh, Kune Y. [Seoul National Univ., Seoul (Korea, Republic of)

    2014-05-15

    Flow characteristic curves are plotted by calculating the ratio of the measured mass flow rate versus the theoretical mass flow rate. The flow characteristic curves are utilized to accurately test the performance of the control valve of turbine system to ensure the highest controllability and reliability of the power conversion system of large and small power plants. Turbine converts the kinetic energy of steam to mechanical energy of rotor blades in power conversion system. The electrical energy output from the generator of which the rotor is coupled with that of the turbine depends on the rotation velocity of the turbine bucket. The rotation velocity is proportional to the mass flow rate (steam or gas) to the turbine through valves and nozzles. The turbine comprises fast acting governing control valves and stop valves acting against the seat in the flow passage in the closed position. The turbine control valve regulates the mass flow rate entering the first nozzle of a turbine. The main function of stop valve is to close the fluid inlet rapidly in response to a fast close signal to swiftly cut off the flow through the valve inlet. Both these valves contribute attractively to improvement of the power system transient stability as well. To improve the efficiency of power conversion system many investigation have been done by researcher by focusing on the cycle layout or working fluid or by improving the flow path of the working fluid. The main focus is to find out the best option for combined cycle power plant by analyzing four different cycle configuration. Next research phase focused on different way to enhance the cycle efficiency. As the electrical power output from the generator is proportional to the mass flow rate to the turbine through the valve, it should preferably operate linearly. In reality, however, the valve has the various flow characteristics pursuant to the stem lift. Thus, the flow characteristic and control performance are needed to be designed

  3. End users heat energy savings using thermostat regulation valves radiators, v. 16(64)

    International Nuclear Information System (INIS)

    Jakimovska, Emilija Misheva; Potsev, Eftim

    2008-01-01

    Billing the used heat energy offers the opportunity to motivate end users to use the heat energy rationally and to save the energy. Installing the thermostat valves on the radiators it is possible frequently to regulate the room temperature and to use the heat gains, obtaining comfortable climate in the apartments and saving the energy. Thermostat valves give the possibility to use the heat energy rationally and save the energy, and these way and users can regulate the heat energy consumption according to their own level of thermal comfort. (Author)

  4. End users heat energy savings using thermostat regulation valves radiators, v. 16(63)

    International Nuclear Information System (INIS)

    Jakimovska, Emilija Misheva; Potsev, Eftim

    2008-01-01

    Billing the used heat energy offers the opportunity to motivate end users to use the heat energy rationally and to save the energy. Installing the thermostat valves on the radiators it is possible frequently to regulate the room temperature and to use the heat gains, obtaining comfortable climate in the apartments and saving the energy. Thermostat valves give the possibility to use the heat energy rationally and save the energy, and these way and users can regulate the heat energy consumption according to their own level of thermal comfort. (Author)

  5. Optimal results of aortic valve replacement with small mechanical valves (< 19 mm).

    Science.gov (United States)

    Kato, Yasuyuki; Hattori, Koji; Motoki, Manabu; Takahashi, Yosuke; Kotani, Shinsuke; Nishimura, Shinsuke; Shibata, Toshihiko

    2013-07-01

    Controversy exists regarding the optimal operative method or type of prosthesis for patients with a small aortic root. The aim of this retrospective study was to investigate the early and mid-term outcomes of standard aortic valve replacement (AVR) using 16 mm or 18 mm ATS Advanced Performance (AP) or 17 mm St. Jude Medical (SJM) Regent valves for a small aortic root. Between April 2003 and August 2009, 78 patients (age range: 50-86 years; 86% aged > or = 65 years) underwent AVR with 16 mm or 18 mm ATS AP valves (16AP group: n = 21, 18AP group: n = 32), or a 17 mm SJM Regent valve (17Regent group: n = 25). Fifty-six patients (72%) had a body surface area (BSA) of regression was similar among the groups (-30%, -25% and -28% in the 16AP, 17Regent and 18AP groups, respectively; p = 0.844). The early and mid-term results of AVR with 16 mm or 18 mm ATS AP valves, or with a 17 mm SJM Regent valve, were satisfactory. Therefore, standard AVR using these small mechanical prostheses, which avoids the need to enlarge the annulus or to conduct stentless bioprosthesis implantation, might represent an acceptable method, especially in elderly patients with a small aortic root.

  6. 3D Fluid-Structure Interaction Simulation of Aortic Valves Using a Unified Continuum ALE FEM Model

    Directory of Open Access Journals (Sweden)

    Jeannette H. Spühler

    2018-04-01

    Full Text Available Due to advances in medical imaging, computational fluid dynamics algorithms and high performance computing, computer simulation is developing into an important tool for understanding the relationship between cardiovascular diseases and intraventricular blood flow. The field of cardiac flow simulation is challenging and highly interdisciplinary. We apply a computational framework for automated solutions of partial differential equations using Finite Element Methods where any mathematical description directly can be translated to code. This allows us to develop a cardiac model where specific properties of the heart such as fluid-structure interaction of the aortic valve can be added in a modular way without extensive efforts. In previous work, we simulated the blood flow in the left ventricle of the heart. In this paper, we extend this model by placing prototypes of both a native and a mechanical aortic valve in the outflow region of the left ventricle. Numerical simulation of the blood flow in the vicinity of the valve offers the possibility to improve the treatment of aortic valve diseases as aortic stenosis (narrowing of the valve opening or regurgitation (leaking and to optimize the design of prosthetic heart valves in a controlled and specific way. The fluid-structure interaction and contact problem are formulated in a unified continuum model using the conservation laws for mass and momentum and a phase function. The discretization is based on an Arbitrary Lagrangian-Eulerian space-time finite element method with streamline diffusion stabilization, and it is implemented in the open source software Unicorn which shows near optimal scaling up to thousands of cores. Computational results are presented to demonstrate the capability of our framework.

  7. 3D Fluid-Structure Interaction Simulation of Aortic Valves Using a Unified Continuum ALE FEM Model.

    Science.gov (United States)

    Spühler, Jeannette H; Jansson, Johan; Jansson, Niclas; Hoffman, Johan

    2018-01-01

    Due to advances in medical imaging, computational fluid dynamics algorithms and high performance computing, computer simulation is developing into an important tool for understanding the relationship between cardiovascular diseases and intraventricular blood flow. The field of cardiac flow simulation is challenging and highly interdisciplinary. We apply a computational framework for automated solutions of partial differential equations using Finite Element Methods where any mathematical description directly can be translated to code. This allows us to develop a cardiac model where specific properties of the heart such as fluid-structure interaction of the aortic valve can be added in a modular way without extensive efforts. In previous work, we simulated the blood flow in the left ventricle of the heart. In this paper, we extend this model by placing prototypes of both a native and a mechanical aortic valve in the outflow region of the left ventricle. Numerical simulation of the blood flow in the vicinity of the valve offers the possibility to improve the treatment of aortic valve diseases as aortic stenosis (narrowing of the valve opening) or regurgitation (leaking) and to optimize the design of prosthetic heart valves in a controlled and specific way. The fluid-structure interaction and contact problem are formulated in a unified continuum model using the conservation laws for mass and momentum and a phase function. The discretization is based on an Arbitrary Lagrangian-Eulerian space-time finite element method with streamline diffusion stabilization, and it is implemented in the open source software Unicorn which shows near optimal scaling up to thousands of cores. Computational results are presented to demonstrate the capability of our framework.

  8. Platelet thrombosis in cardiac-valve prostheses

    International Nuclear Information System (INIS)

    Dewanjee, M.K.

    1989-01-01

    The contribution of platelets and clotting factors in thrombosis on cardiovascular prostheses had been quantified with several tracers. Thrombus formation in vivo could be measured semiquantitatively in animal models and patients with indium-111, Technetium-99m labeled platelets, iodine-123, iodine-131 labeled fibrinogen, and In-111 and Tc-99m labeled antibody to the fibrinogen-receptor on the platelet- membrane, or fibrin. The early studies demonstrated that certain platelet-inhibitors, e.g. sulfinpyrazone, aspirin or aspirin- persantine increased platelet survival time with mechanical valves implanted in the baboon model and patients. Thrombus localization by imaging is possible for large thrombus on thrombogenic surface of prosthesis in the acute phase. The majority of thrombus was found in the sewing ring (Dacron) in the acute phase in both the mechanical and tissue valves. The amount of retained thrombus in both mechanical and tissue valves in our one-day study in the dog model was similar (< 1% if injected In-111 platelets = 5 billion platelets). As the fibrous ingrowth covered the sewing ring, the thrombus formation decreased significantly. Only a small amount of thrombus was found on the leaflets at one month in both the dog and calf models. 38 refs., 9 figs., 5 tabs

  9. Platelet thrombosis in cardiac-valve prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Dewanjee, M.K.

    1989-01-01

    The contribution of platelets and clotting factors in thrombosis on cardiovascular prostheses had been quantified with several tracers. Thrombus formation in vivo could be measured semiquantitatively in animal models and patients with indium-111, Technetium-99m labeled platelets, iodine-123, iodine-131 labeled fibrinogen, and In-111 and Tc-99m labeled antibody to the fibrinogen-receptor on the platelet- membrane, or fibrin. The early studies demonstrated that certain platelet-inhibitors, e.g. sulfinpyrazone, aspirin or aspirin- persantine increased platelet survival time with mechanical valves implanted in the baboon model and patients. Thrombus localization by imaging is possible for large thrombus on thrombogenic surface of prosthesis in the acute phase. The majority of thrombus was found in the sewing ring (Dacron) in the acute phase in both the mechanical and tissue valves. The amount of retained thrombus in both mechanical and tissue valves in our one-day study in the dog model was similar (< 1% if injected In-111 platelets = 5 billion platelets). As the fibrous ingrowth covered the sewing ring, the thrombus formation decreased significantly. Only a small amount of thrombus was found on the leaflets at one month in both the dog and calf models. 38 refs., 9 figs., 5 tabs.

  10. Development of an effective valve packing program

    Energy Technology Data Exchange (ETDEWEB)

    Hart, K.A.

    1996-12-01

    Current data now shows that graphite valve packing installed within the guidance of a controlled program produces not only reliable stem sealing but predictable running loads. By utilizing recent technological developments in valve performance monitoring for both MOV`s and AOV`s, valve packing performance can be enhanced while reducing maintenance costs. Once known, values are established for acceptable valve packing loads, the measurement of actual valve running loads via the current MOV/AOV diagnostic techniques can provide indication of future valve stem sealing problems, improper valve packing installation or identify the opportunity for valve packing program improvements. At times the full benefit of these advances in material and predictive technology remain under utilized due to simple past misconceptions associated with valve packing. This paper will explore the basis for these misconceptions, provide general insight into the current understanding of valve packing and demonstrate how with this new understanding and current valve diagnostic equipment the key aspects required to develop an effective, quality valve packing program fit together. The cost and operational benefits provided by this approach can be significant impact by the: elimination of periodic valve repacking, reduction of maintenance costs, benefits of leak-free valve operation, justification for reduced Post Maintenance Test Requirements, reduced radiation exposure, improved plant appearance.

  11. Inverse spin-valve effect in nanoscale Si-based spin-valve devices

    Science.gov (United States)

    Hiep, Duong Dinh; Tanaka, Masaaki; Hai, Pham Nam

    2017-12-01

    We investigated the spin-valve effect in nano-scale silicon (Si)-based spin-valve devices using a Fe/MgO/Ge spin injector/detector deposited on Si by molecular beam epitaxy. For a device with a 20 nm Si channel, we observed clear magnetoresistance up to 3% at low temperature when a magnetic field was applied in the film plane along the Si channel transport direction. A large spin-dependent output voltage of 20 mV was observed at a bias voltage of 0.9 V at 15 K, which is among the highest values in lateral spin-valve devices reported so far. Furthermore, we observed that the sign of the spin-valve effect is reversed at low temperatures, suggesting the possibility of a spin-blockade effect of defect states in the MgO/Ge tunneling barrier.

  12. Mechanical versus bioprosthetic aortic valve replacement.

    Science.gov (United States)

    Head, Stuart J; Çelik, Mevlüt; Kappetein, A Pieter

    2017-07-21

    Mechanical valves used for aortic valve replacement (AVR) continue to be associated with bleeding risks because of anticoagulation therapy, while bioprosthetic valves are at risk of structural valve deterioration requiring reoperation. This risk/benefit ratio of mechanical and bioprosthetic valves has led American and European guidelines on valvular heart disease to be consistent in recommending the use of mechanical prostheses in patients younger than 60 years of age. Despite these recommendations, the use of bioprosthetic valves has significantly increased over the last decades in all age groups. A systematic review of manuscripts applying propensity-matching or multivariable analysis to compare the usage of mechanical vs. bioprosthetic valves found either similar outcomes between the two types of valves or favourable outcomes with mechanical prostheses, particularly in younger patients. The risk/benefit ratio and choice of valves will be impacted by developments in valve designs, anticoagulation therapy, reducing the required international normalized ratio, and transcatheter and minimally invasive procedures. However, there is currently no evidence to support lowering the age threshold for implanting a bioprosthesis. Physicians in the Heart Team and patients should be cautious in pursuing more bioprosthetic valve use until its benefit is clearly proven in middle-aged patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  13. One-way quantum repeaters with quantum Reed-Solomon codes

    Science.gov (United States)

    Muralidharan, Sreraman; Zou, Chang-Ling; Li, Linshu; Jiang, Liang

    2018-05-01

    We show that quantum Reed-Solomon codes constructed from classical Reed-Solomon codes can approach the capacity on the quantum erasure channel of d -level systems for large dimension d . We study the performance of one-way quantum repeaters with these codes and obtain a significant improvement in key generation rate compared to previously investigated encoding schemes with quantum parity codes and quantum polynomial codes. We also compare the three generations of quantum repeaters using quantum Reed-Solomon codes and identify parameter regimes where each generation performs the best.

  14. Tomographic and echocardiographic diagnosis of mitral prosthetic valve thrombosis

    International Nuclear Information System (INIS)

    Sainz Gonzalez de la Penna, Benito; Ramos Gutierrez, Luis Benito; Gonzalez Artiles, Iovank

    2010-01-01

    Despite the progress achieved in the design of mechanical prosthetic valves, prosthetic valve thrombosis remains a frequent cause of morbidity, usually due to incorrect anticoagulation. A patient was presented with mitral prosthetic thrombosis one year after implantation, who had been diagnosed by transthoracic transesophageal echocardiography imaging and 64-slice computed tomography. Thrombolytic therapy was successful and led to the satisfactory evolution of the patient

  15. Surge-damping vacuum valve

    International Nuclear Information System (INIS)

    Bullock, J.C.; Kelley, B.E.

    1977-01-01

    A valve for damping out flow surges in a vacuum system is described. The surge-damping mechanism consists of a slotted, spring-loaded disk adjacent to the valve's vacuum port (the flow passage to the vacuum roughing pump). Under flow surge conditions, the differential pressure forces the disk into a sealing engagement with the vacuum port, thereby restricting the gas flow path to narrow slots in the disk's periphery. The increased flow damps out the flow surge. When pressure is equalized on both sides of the valve, the spring load moves the disk away from the port to restore full flow conductance through the valve

  16. Depth of valve implantation, conduction disturbances and pacemaker implantation with CoreValve and CoreValve Accutrak system for Transcatheter Aortic Valve Implantation, a multi-center study.

    Science.gov (United States)

    Lenders, Guy D; Collas, Valérie; Hernandez, José Maria; Legrand, Victor; Danenberg, Haim D; den Heijer, Peter; Rodrigus, Inez E; Paelinck, Bernard P; Vrints, Christiaan J; Bosmans, Johan M

    2014-10-20

    Transcatheter Aortic Valve Implantation (TAVI) is now considered an indispensable treatment strategy in high operative risk patients with severe, symptomatic aortic stenosis. However, conduction disturbances and the need for Permanent Pacemaker (PPM) implantation after TAVI with the CoreValve prosthesis still remain frequent. We aimed to evaluate the implantation depth, the incidence and predictors of new conduction disturbances, and the need for PPM implantation within the first month after TAVI, using the new Accutrak CoreValve delivery system (ACV), compared to the previous generation CoreValve (non-ACV). In 5 experienced TAVI-centers, a total of 120 consecutive non-ACV and 112 consecutive ACV patients were included (n=232). The mean depth of valve implantation (DVI) was 8.4±4.0 mm in the non-ACV group and 7.1±4.0 mm in the ACV group (p=0.034). The combined incidence of new PPM implantation and new LBBB was 71.2% in the non-ACV group compared to 50.5% in the ACV group (p=0.014). DVI (p=0.002), first degree AV block (p=0.018) and RBBB (p<0.001) were independent predictors of PPM implantation. DVI (p<0.001) and pre-existing first degree AV-block (p=0.021) were identified as significant predictors of new LBBB. DVI is an independent predictor of TAVI-related conduction disturbances and can be reduced by using the newer CoreValve Accutrak delivery system, resulting in a significantly lower incidence of new LBBB and new PPM implantation. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. PARAMETER ESTIMATION OF VALVE STICTION USING ANT COLONY OPTIMIZATION

    Directory of Open Access Journals (Sweden)

    S. Kalaivani

    2012-07-01

    Full Text Available In this paper, a procedure for quantifying valve stiction in control loops based on ant colony optimization has been proposed. Pneumatic control valves are widely used in the process industry. The control valve contains non-linearities such as stiction, backlash, and deadband that in turn cause oscillations in the process output. Stiction is one of the long-standing problems and it is the most severe problem in the control valves. Thus the measurement data from an oscillating control loop can be used as a possible diagnostic signal to provide an estimate of the stiction magnitude. Quantification of control valve stiction is still a challenging issue. Prior to doing stiction detection and quantification, it is necessary to choose a suitable model structure to describe control-valve stiction. To understand the stiction phenomenon, the Stenman model is used. Ant Colony Optimization (ACO, an intelligent swarm algorithm, proves effective in various fields. The ACO algorithm is inspired from the natural trail following behaviour of ants. The parameters of the Stenman model are estimated using ant colony optimization, from the input-output data by minimizing the error between the actual stiction model output and the simulated stiction model output. Using ant colony optimization, Stenman model with known nonlinear structure and unknown parameters can be estimated.

  18. Characteristic analysis of servo valve

    International Nuclear Information System (INIS)

    Ko, J. H.; Ryu, D. R.; Lee, J. H.; Kim, Y. S.; Na, J. C.; Kim, D. S.

    2008-01-01

    Electro-pneumatic servo valve is an electro-mechanical device which converts electric signals into a proper pneumatic flow rate or pressure. In order to improve the overall performance of pneumatic servo systems, electro-pneumatic servo valves are required, which have fast dynamic characteristics, no air leakage at a null point, and can be fabricated at a low-cost. The first objective of this research is to design and to fabricate a new electro-pneumatic servo valve which satisfies the above-mentioned requirements. In order to design the mechanism of the servo valve optimally, the flow inside the valve depending upon the position of spool was analyzed variously, and on the basis of such analysis results, the valve mechanism, which was formed by combination of the spool and the sleeve, was designed and manufactured. And a tester for conducting an overall performance test was designed and manufactured, and as a result of conducting the flow rate test, the pressure test and the frequency test on the developed pneumatic servo valve

  19. Acute Mitral Valve Dysfunction Due to Escape of Prosthetic Mechanical Leaflet and Peripheral Leaftlet Embolization.

    Science.gov (United States)

    Calik, Eyup Serhat; Limandal, Husnu Kamil; Arslan, Umit; Tort, Mehmet; Yildiz, Ziya; Bayram, Ednan; Dag, Ozgur; Kaygin, Mehmet Ali; Erkut, Bilgehan

    2015-12-14

    Leaflet escape of prosthetic valve is rare but potentially life threatening. Early diagnosis is essential on account of avoiding mortality, and emergency surgical correction is compulsory. This complication has previously been reported for both monoleaflet and bileaflet valve models. A 30-year-old man who had undergone mitral valve replacement with a bileaflet valve 8 years prior at another center was admitted with acute-onset with cardiogenic shock as an emergency case. Transthoracic echocardiograms showed acute-starting severe mitral regurgitation associated with prosthetic mitral valve. There was a suspicious finding of a single prosthetic mitral leaflet. But the problem related with the valve wasn't specifically determined. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. There was no tissue impingement and thrombosis, one of the two leaflets was absent, and there were no signs of endocarditis or pannus formation in the prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet during surgery. The damaged valve was removed and a replacement 29 mm bileaflet mechanical valve was inserted by right lateral thoracotomy. After post-operative week one, the abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the left femoral artery. Fifteen days after the surgery the escaped leaflet was removed safely from the left femoral artery and the patient made a complete recovery. The escaped leaflet showed a fracture of one of the pivot systems caused by structural failure. Early cardiac surgery should be applied because of life-threatening problems.

  20. Small sodium valve design and operating experience

    International Nuclear Information System (INIS)

    Abramson, R.; Elie, X.; Vercasson, M.; Nedelec, J.

    1974-01-01

    Conventionally, valves for sodium pipes smaller than 125 mm in diameter are called ''small sodium valves''. However, this limit should rather be considered as the lower limit o ''large sodium valves''. In fact, both the largest sizes of small valves and the smallest of large valves can be found in the range of 125-300 mm in diameter. Thus what is said about small valves also applies, for a few valve types, above the 125 mm limit. Sodium valves are described here in a general manner, with no manufacturing details except when necessary for understanding valve behavior. Operating experience is pointed out wherever possible. Finally, some information is given about ongoing or proposed development plans. (U.S.)

  1. Implementation of an enlarged model of the safety valves and relief in the plant integral model for the code RELAP/SCDAPSIM

    International Nuclear Information System (INIS)

    Amador G, R.; Ortiz V, J.; Castillo D, R.; Hernandez L, E. J.; Galeana R, J. C.; Gutierrez, V. H.

    2013-10-01

    The present work refers to the implementation of a new model on the logic of the safety valves and relief in the integral model of the Nuclear Power Plant of Laguna Verde of the thermal-hydraulic compute code RELAP/SCDAPSIM Mod. 3.4. The new model was developed with the compute package SIMULINK-MATLAB and contemplates all the operation options of the safety valves and relief, besides including the availability options of the valves in all the operation ways and of blockage in the ways of relief and low-low. The implementation means the elimination of the old model of the safety valves and to analyze the group of logical variables, of discharge and available control systems to associate them to the model of package SIMULINK-MATLAB. The implementation has been practically transparent and 27 cases corresponding to a turbine discharge were analyzed with the code RELAP/SCDAPSIM Mod. 3.4. The results were satisfactory. (Author)

  2. Griswold Tempered Water Flow Regulator Valves Used as Anti-Siphon Valves

    International Nuclear Information System (INIS)

    MISKA, C.

    2000-01-01

    FCV-1*22 and 1*23 are Griswold constant flow regulators used as anti-siphon valves in the tempered water system, they fail closed but valve cartridge orifice allows minimum flow to prevent loss of water from the MCO/CASK annulus

  3. Shape of the dilated aorta in children with bicuspid aortic valve

    International Nuclear Information System (INIS)

    Mart, Christopher R; McNerny, Bryn E

    2013-01-01

    The dilated aorta in adults with bicuspid aortic valve has been shown to have different shapes, but it is not known if this occurs in children. This observational study was performed to determine if there are different shapes of the dilated aorta in children with bicuspid aortic valve and their association with age, gender, hemodynamic alterations, and degree of aortic enlargement. One hundred and eighty-seven echocardiograms done on pediatric patients (0 – 18 years) for bicuspid aortic valve, during 2008, were reviewed. Aortic valve morphology, shape/size of the aorta, and pertinent hemodynamic alterations were documented. Aortic dilation was felt to be present when at least one aortic segment had a z-score > 2.0; global aortic enlargement was determined by summing the aortic segment z-scores. The aortic shape was assessed by age, gender, valve morphology, and hemodynamic alterations. Aortic dilation was present in 104/187 patients. The aorta had six different shapes designated from S1 through S6. There was no association between the aortic shape and gender, aortic valve morphology, or hemodynamic abnormalities. S3 was the most common after the age of six years and was associated with the most significant degree of global aortic enlargement. The shape of the dilated aorta in children with bicuspid aortic valve does not occur in a uniform manner and multiple shapes are seen. S2 and S3 are most commonly seen. As aortic dilation becomes more significant, a single shape (S3) becomes the dominant pattern

  4. Computed Flow Through An Artificial Heart And Valve

    Science.gov (United States)

    Rogers, Stuart E.; Kwak, Dochan; Kiris, Cetin; Chang, I-Dee

    1994-01-01

    NASA technical memorandum discusses computations of flow of blood through artificial heart and through tilting-disk artificial heart valve. Represents further progress in research described in "Numerical Simulation of Flow Through an Artificial Heart" (ARC-12478). One purpose of research to exploit advanced techniques of computational fluid dynamics and capabilities of supercomputers to gain understanding of complicated internal flows of viscous, essentially incompressible fluids like blood. Another to use understanding to design better artificial hearts and valves.

  5. Effects of aging and service wear on main steam isolation valves and valve operators

    International Nuclear Information System (INIS)

    Clark, R.L.

    1996-03-01

    In recent years main steam isolation valve (MSIV operating problems have resulted in significant operational transients (e.g., spurious reactor trips, steam generator dry out, excessive valve seat leakage), increased cost, and decreased plant availability. A key ingredient to an engineering-oriented reliability improvement effort is a thorough understanding of relevant historical experience. A detailed review of historical failure data available through the Institute of Nuclear Power Operation's Nuclear Plant Reliability Data System has been conducted for several types of MSIVs and valve operators for both boiling-water reactors and pressurized-water reactors. The focus of this review is on MSIV failures modes, actuator failure modes, consequences of failure on plant operations, method of failure detection, and major stressors affecting both valves and valve operators

  6. Valve-sparing aortic root replacement†

    NARCIS (Netherlands)

    Koolbergen, David R.; Manshanden, Johan S. J.; Bouma, Berto J.; Blom, Nico A.; Mulder, Barbara J. M.; de Mol, Bas A. J. M.; Hazekamp, Mark G.

    2015-01-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed.

  7. Mitral valve-sparing procedures and prosthetic heart valve failure: A case report

    Science.gov (United States)

    Khan, Nasir A; Butany, Jagdish; Leong, Shaun W; Rao, Vivek; Cusimano, Robert J; Ross, Heather J

    2009-01-01

    Prosthetic heart valve dysfunction due to thrombus or pannus formation can be a life-threatening complication. The present report describes a 47-year-old woman who developed valvular cardiomyopathy after chorda-sparing mitral valve replacement, and subsequently underwent heart transplantation for progressive heart failure. The explanted mitral valve prosthesis showed significant thrombus and pannus leading to reduced leaflet mobility and valvular stenosis. The present report illustrates the role of the subvalvular apparatus and pannus in prosthesis dysfunction. PMID:19279993

  8. A study of waste and delivery valve design modification to the pump performance

    Science.gov (United States)

    Harith, M. N.; Bakar, R. A.; Ramasamy, D.; Kardigama, K.; Quanjin, Ma

    2018-04-01

    This paper objective is to share design revolution of waste and delivery valve that contribute to the overall pump performance. In this paper, 3 new designs of waste and delivery valve pump are presented with comprehensive internal flow analysis using computational fluid dynamics (CFD) simulation over 4 cases that have been deeply study for one of the design chosen. 4 cases involving opening and closing both valve or either one. 0.265m height size of customized waste valve with an opening limiter and spring was used to demonstrate cyclic closing and opening valve operation extended up to 0.164m gap. Based on result, this characteristics contribute to 10-20% waste water reduction and enhancement of flow rate height up to 80m. Apart from that this paper also share some of pressure (dynamic, total, static), velocity (x, y, z axis) simulation including the vector flow were under different flow cases.

  9. Aerococcus viridans Native Valve Endocarditis

    Directory of Open Access Journals (Sweden)

    Wenwan Zhou

    2013-01-01

    Full Text Available Aerococcus viridans is an infrequent human pathogen and few cases of infective endocarditis have been reported. A case involving a 69-year-old man with colon cancer and hemicolectomy 14 years previously, without recurrence, is reported. A diagnosis of native mitral valve endocarditis was established on the basis of clinical presentation, characteristic echocardiographic findings and pathological specimen examination after urgent valve replacement. A viridans endocarditis appears to be particularly virulent, requiring a surgical approach in four of 10 cases reported and death in one of nine. Given the aggressive nature of A viridans endocarditis and the variable time to diagnosis (a few days to seven months, prompt recognition of symptoms and echocardiography, in addition to blood cultures, should be performed when symptoms persist.

  10. Simple Check Valves for Microfluidic Devices

    Science.gov (United States)

    Willis, Peter A.; Greer, Harold F.; Smith, J. Anthony

    2010-01-01

    A simple design concept for check valves has been adopted for microfluidic devices that consist mostly of (1) deformable fluorocarbon polymer membranes sandwiched between (2) borosilicate float glass wafers into which channels, valve seats, and holes have been etched. The first microfluidic devices in which these check valves are intended to be used are micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. In this application, it will be necessary to store some liquid samples in reservoirs in the devices for subsequent laboratory analysis, and check valves are needed to prevent cross-contamination of the samples. The simple check-valve design concept is also applicable to other microfluidic devices and to fluidic devices in general. These check valves are simplified microscopic versions of conventional rubber- flap check valves that are parts of numerous industrial and consumer products. These check valves are fabricated, not as separate components, but as integral parts of microfluidic devices. A check valve according to this concept consists of suitably shaped portions of a deformable membrane and the two glass wafers between which the membrane is sandwiched (see figure). The valve flap is formed by making an approximately semicircular cut in the membrane. The flap is centered over a hole in the lower glass wafer, through which hole the liquid in question is intended to flow upward into a wider hole, channel, or reservoir in the upper glass wafer. The radius of the cut exceeds the radius of the hole by an amount large enough to prevent settling of the flap into the hole. As in a conventional rubber-flap check valve, back pressure in the liquid pushes the flap against the valve seat (in this case, the valve seat is the adjacent surface of the lower glass wafer), thereby forming a seal that prevents backflow.

  11. Piezoelectric valve for massive gas injection in ASDEX upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Dibon, Mathias; Neu, Rudolf [Max-Planck-Institute for Plasmaphysics, Boltzmannstr. 2, 85748 Garching (Germany); Technical University Munich, Boltzmannstr. 15, 85748 Garching (Germany); Herrmann, Albrecht; Mank, Klaus; Mertens, Vitus; Pautasso, Gabriella; Ploeckl, Bernhard [Max-Planck-Institute for Plasmaphysics, Boltzmannstr. 2, 85748 Garching (Germany)

    2016-07-01

    A sudden loss of plasma temperature can cause a disruption, which poses a significant problem for current Tokamaks and future fusion devices. Hence, mitigating forces and thermal loads during disruptions is important for the integrity of the vessel and first wall components. Therefore, high speed gas valves are used to deliver a pulse of noble gas onto the plasma, which irradiates the thermal energy quickly, avoiding localized heat loads and mechanical stress due to induced currents. A new design for such a valve is currently under development. The valve plate is driven by two piezoelectric stack actuators. The stroke of the actuators (0.07 mm) is amplified by a monolithic titanium frame and reaches 2 mm. The frame also serves as spring to pre-load the actuators. In the idle state, it also presses the conical valve plate into the seal, closing the gas chamber (42 cm{sup 3}). The actuators accelerate the stem and the valve plate until it is fully opened after 2 ms. The orifice of the valve has a diameter of 14 mm. This allows a peak mass flow rate of the gas up to 8 . 10{sup 4} (Pa.m)/(s) after 1.8 ms and an average mass flow rate of 2 . 10{sup 4} (Pa.m)/(s) over the evacuation time of 10 ms. Therefore, one valve would be sufficient to deliver the required amount of gas to mitigate disruptions at ASDEX Upgrade.

  12. Heart valve replacement with the Sorin tilting-disc prosthesis. A 10-year experience.

    Science.gov (United States)

    Milano, A; Bortolotti, U; Mazzucco, A; Mossuto, E; Testolin, L; Thiene, G; Gallucci, V

    1992-02-01

    From 1978 to 1988, 697 patients with a mean age of 48 +/- 11 years (range 5 to 75 years) received a Sorin tilting-disc prosthesis; 358 had had aortic valve replacement, 247 mitral valve replacement, and 92 mitral and aortic valve replacement. Operative mortality rates were 7.8%, 11.3%, and 10.8%, respectively, in the three groups. Cumulative duration of follow-up is 1650 patient-years for aortic valve replacement (maximum follow-up 11.4 years), 963 patient-years for mitral valve replacement (maximum follow-up 9.9 years) and 328 patient-years for mitral and aortic valve replacement (maximum follow-up 9.4 years). Actuarial survival at 9 years is 72% +/- 4% after mitral valve replacement, 70% +/- 3% after aortic valve replacement, and 50% +/- 12% after mitral and aortic valve replacement, and actuarial freedom from valve-related deaths is 97% +/- 2% after mitral valve replacement, 92% +/- 2% after aortic valve replacement, and 62% +/- 15% after mitral and aortic valve replacement. Thromboembolic events occurred in 21 patients with aortic valve replacement (1.3% +/- 0.2%/pt-yr), in 12 with mitral valve replacement (1.2% +/- 0.3% pt-yr), and in seven with mitral and aortic valve replacement (2.1% +/- 0.8%), with one case of prosthetic thrombosis in each group; actuarial freedom from thromboembolism at 9 years is 92% +/- 3% after mitral valve replacement, 91% +/- 3% after aortic valve replacement, and 74% +/- 16% after mitral and aortic valve replacement. Anticoagulant-related hemorrhage was observed in 15 patients after aortic valve replacement (0.9% +/- 0.2%/pt-yr), in 9 after mitral valve replacement (0.9% +/- 0.3%/pt-yr), and in 6 with mitral and aortic valve replacement (0.9% +/- 0.5%/pt-yr); actuarial freedom from this complication at 9 years is 94% +/- 2% after aortic valve replacement, 91% +/- 4% after mitral valve replacement, and 68% +/- 16% after mitral and aortic valve replacement. Actuarial freedom from reoperation at 9 years is 97% +/- 2% after mitral and

  13. Aortic Regurgitation in Patients Undergoing Transcatheter Aortic Valve Replacement With the Self-Expanding CoreValve Versus the Balloon-Expandable SAPIEN XT Valve.

    Science.gov (United States)

    Kiramijyan, Sarkis; Magalhaes, Marco A; Koifman, Edward; Didier, Romain; Escarcega, Ricardo O; Baker, Nevin C; Negi, Smita I; Minha, Sa'ar; Torguson, Rebecca; Jiaxiang, Gai; Asch, Federico M; Wang, Zuyue; Okubagzi, Petros; Gaglia, Michael A; Ben-Dor, Itsik; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2016-05-01

    The incidence of aortic regurgitation (AR) after transcatheter aortic valve replacement (TAVR) in a self-expanding and a balloon-expandable system is controversial. This study aimed to examine the incidence and severity of post-TAVR AR with the CoreValve (CV) versus the Edwards XT Valve (XT). Baseline, procedural, and postprocedural inhospital outcomes were compared. The primary end point was the incidence of post-TAVR AR of any severity, assessed with a transthoracic echocardiogram, in the CV versus XT groups. A multivariate logistic regression analysis was completed to evaluate for correlates of the primary end point. The secondary end points included the change in severity of AR at 30-day and 1-year follow-up. A total of 223 consecutive patients (53% men, mean age 82 years) who had transfemoral TAVR with either a CV (n = 119) or XT (n = 104) were evaluated. The rates of post-TAVR AR in the groups were similar, and there was no evidence of more-than-moderate AR in either group. There were significant differences in the rates of intraprocedural balloon postdilation with the CV (17.1%) versus XT valve (5.8%; p = 0.009) and in the rates of intraprocedural implantation of a second valve-in-valve prosthesis with the CV (9.9%) versus XT valve (2.2%; p = 0.036). There were no significant differences in inhospital safety outcomes between the 2 groups. In conclusion, the incidence of post-TAVR AR is similar between the CV and the XT valve when performed by experienced operators using optimal intraprocedural strategies, as deemed appropriate, to mitigate the severity of AR. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Pannus Formation Leads to Valve Malfunction in the Tricuspid Position 19 Years after Triple Valve Replacement.

    Science.gov (United States)

    Alskaf, Ebraham; McConkey, Hannah; Laskar, Nabila; Kardos, Attila

    2016-06-20

    The Medtronic ATS Open Pivot mechanical valve has been successfully used in heart valve surgery for more than two decades. We present the case of a patient who, 19 years following a tricuspid valve replacement with an ATS prosthesis as part of a triple valve operation following infective endocarditis, developed severe tricuspid regurgitation due to pannus formation.

  15. Recurrent pannus formation causing prosthetic aortic valve dysfunction: is excision without valve re-replacement applicable?

    Science.gov (United States)

    Darwazah, Ahmad K

    2012-06-29

    Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function.The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement.A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve.Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.

  16. Performance Comparison of Reservation Based and Instant Access One-Way Car Sharing Service through Discrete Event Simulation

    Directory of Open Access Journals (Sweden)

    Ganjar Alfian

    2015-09-01

    Full Text Available A car sharing service has been highlighted as a new urban transport alternative for an environmentally friendly economy. As the demand for the service from customers increases, car sharing operators need to introduce a new service such as a one-way option that will allow customers to return the car to different stations. Due to the complexity of the one-way system, it needs to be managed and optimized for real cases. This paper focuses on developing a simulation model in order to help operators evaluate the performance of the one-way service. In addition, this research demonstrates a strategy for an open one-way service that can increase revenue and customer satisfaction. A real case dataset is used for investigation to find the best result from the simulation. The result showed that the total number of cars, number of one-way reservations and station size have an impact on one-way performance. Thus, company profit and customer satisfaction can be maximized by optimizing these factors.

  17. Axial computed tomography evaluation of the internal nasal valve correlates with clinical valve narrowing and patient complaint.

    Science.gov (United States)

    Moche, Jason A; Cohen, Justin C; Pearlman, Steven J

    2013-07-01

    The objective of this work was to explore the utility of axial computed tomography (CT) imaging to objectively define a narrow internal nasal valve, and compare those findings with clinical examination and patient complaint. Retrospective review from a single facial plastic surgery center. We reviewed 40 consecutive patients evaluated for either sinusitis or nasal airway obstruction for which a CT scan was obtained at a single radiology institution. Thirty-six complete office records were examined for the presence of clinical internal valve narrowing and complaints of nasal obstruction. In total, 72 internal nasal valves were analyzed using axial plane CT and measurements were compared to clinical findings and presence of airway obstruction. Measured valve areas for clinically normal internal nasal valves averaged 0.47 cm(2) vs 0.28 cm(2) for clinically narrow valves, a decrease of 40.4%. In unobstructed nasal airways the valve area averaged 0.51 cm(2) vs 0.38 cm(2) in obstructed airways, a difference of 25.5%. A radiographically measured valve area of <0.30 cm(2) suggests clinical narrowing with a sensitivity of 71.4%, specificity of 88.9%, positive predictive value of 62.5%, and negative predictive value of 92.3%. Using standard axial CT imaging we describe an objective method of radiographically evaluating the nasal valve, demonstrating strong correlation with physical examination and patient complaint. Additionally, radiographic valve areas can be used to screen for clinically narrow nasal valves with good sensitivity and specificity, providing a novel straightforward method for nasal valve assessment. © 2012 ARS-AAOA, LLC.

  18. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, Jordan [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States); Ansanelli, Eric [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States)

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market.

  19. Small sodium valve design and operating experience

    International Nuclear Information System (INIS)

    McGough, C.B.

    1974-01-01

    The United States Liquid Metal Fast Breeder Reactor program (LMFBR) includes an extensive program devoted to the development of small sodium valves. This program is now focused on the development and production of valves for the Fast Flux Test Facility (FFTF) now under construction near Richland, Washington. Other AEC support facilities, such as various test loops located at the Liquid Metal Engineering Center (LMEC), Los Angeles, California, and at the Hanford Engineering Development Laboratory (HEDL), Richland, Washington, also have significant requirements for small sodium valves, and valves similar in design to the FFTF valves are being supplied to these AEC laboratories for use in their critical test installations. A principal motivation for these valve programs, beyond the immediate need to provide high-reliability valves for FFTF and the support facilities, is the necessity to develop small valve technology for the Clinch River Breeder Reactor Plant (CRBRP). FFTF small sodium valve design and development experience will be directly applied to the CRBRP program. Various test programs have been, and are being, conducted to verify the performance and integrity of the FFTF valves, and to uncover any potential problems so that they can be corrected before the valves are placed in service in FFTF. The principal small sodium valve designs being utilized in current U.S. programs, the test and operational experience obtained to date on them, problems uncovered, and future development and testing efforts being planned are reviewed. The standards and requirements to which the valves are being designed and fabricated, the valve designs in current use, valve operators, test and operating experience, and future valve development plans are summarized. (U.S.)

  20. Torque characteristics of a 122-centimeter butterfly valve with a hydro/pneumatic actuator

    Science.gov (United States)

    Lin, F. N.; Moore, W. I.; Lundy, F. E.

    1981-01-01

    Actuating torque data from field testing of a 122-centimeter (48 in.) butterfly valve with a hydro/pneumatic actuator is presented. The hydraulic cylinder functions as either a forward or a reverse brake. Its resistance torque increases when the valve speeds up and decreases when the valve slows down. A reduction of flow resistance in the hydraulic flow path from one end of the hydraulic cylinder to the other will effectively reduce the hydraulic resistance torque and hence increase the actuating torque. The sum of hydrodynamic and friction torques (combined resistance torque) of a butterfly valve is a function of valve opening time. An increase in the pneumatic actuating pressure will result in a decrease in both the combined resistance torque and the actuator opening torque; however, it does shorten the valve opening time. As the pneumatic pressure increases, the valve opening time for a given configuration approaches an asymptotical value.

  1. MANAGEMENT OF FAILED MITRAL VALVE REPLACEMENT. THE DURBAN EXPERIENCE.

    Science.gov (United States)

    Kistan, D; Booysen, M; Alexander, G; Madiba, T E

    2017-06-01

    Mitral valve replacement is the procedure of choice in patients with severe mitral valve disease. However, these patients are surviving longer and are thus at an increased risk of prosthesis failure or valve-related complications. Study setting: Inkosi Albert Luthuli Central Hospital, a tertiary referral Hospital in Durban. Study population: All patients undergoing redo mechanical mitral valve replacement surgery between January 2005 and December 2014. Study design: Retrospective analysis of patients undergoing redo mitral valve replacement. Patients were identified from theatre record books, their files were electronically accessed and pertinent information extracted onto a data capture sheet. Information documented included demographics, duration to failure, INR, Albumin, HIV status, clinical findings and outcome. The data was stored on an Excel datasheet. Fifty-eight patients were documented (mean age 32 ± 15.81 years; M:F 1:3). Ten patients (17%) were HIV positive (median CD4 count 478). Mean duration between first surgery and redo was 8.8 years. Thirty-five patients (60%) had no co-morbidities. Presenting features at redo surgery were congestive cardiac failure (27), chest pain (11) and palpitations (17). Mean preoperative Ejection Fraction was 51.65 %. Twenty-nine patients (55%) had emergency redo surgery. Twenty-two patients (75%) had acute prosthetic valve thrombosis. Thirty-two patients had tricuspid regurgitation. Original pathology was documented in 23 patients (40%) as Rheumatic valve disease. Prosthetic valve thrombosis was documented in 31 patients (54%). The most commonly used valve was the On-X. Mean presenting INR was 1.96 + 1.2 and mean presenting serum albumin was 36.7 + 7.8 g/l. Forty-one patients (71%) were found to be compliant to Warfarin therapy prior to redo surgery. Mean ICU stay was 6 +9 days. Two patients died postoperatively. Mean followup was 32 + 26.6 months. Twelve patients (20.7%) developed postoperative complications. Patients

  2. Developments in mechanical heart valve prosthesis

    Indian Academy of Sciences (India)

    Artificial heart valves are engineered devices used for replacing diseased or damaged natural valves of the heart. Most commonly used for replacement are mechanical heart valves and biological valves. This paper briefly outlines the evolution, designs employed, materials being used,. and important factors that affect the ...

  3. Ball check valve

    International Nuclear Information System (INIS)

    Bevilacqua, F.

    1978-01-01

    A pressurized nuclear reactor having an instrument assembly sheathed in a metallic tube which is extended vertically upward into the reactor core by traversing a metallic guide tube which is welded to the wall of the vessel is described. Sensors in each instrument assembly are connected to instruments outside the vessel to manifest the conditions within the core. Each instrument assembly probe is moved into position within a metallic guide channel. The guide channel penetrates the wall of the vessel and forms part of the barrier to the environment within the pressure vessel. Each channel includes a ball check valve which is opened by the instrument assembly probe when the probe passes through the valve. A ball valve element is moved from its seat by the probe to a position lateral of the bore of the channel and is guided to its seat along a sloped path within the valve body when the probe is removed. 5 claims, 3 figures

  4. Two-way against one-way nesting for climate downscaling in Europe and the Mediterranean region using LMDZ4

    Science.gov (United States)

    Li, Shan; Li, Laurent; Le Treut, Hervé

    2016-04-01

    In the 21st century, the estimated surface temperature warming projected by General Circulation Models (GCMs) is between 0.3 and 4.8 °C, depending on the scenario considered. GCMs exhibit a good representation of climate on a global scale, but they are not able to reproduce regional climate processes with the same level of accuracy. Society and policymakers need model projections to define climate change adaptation and mitigation policies on a global, regional and local scale. Climate downscaling is mostly conducted with a regional model nested into the outputs of a global model. This one-way nesting approach is generally used in the climate community without feedbacks from Regional Climate Models (RCMs) to GCMs. This lack of interaction between the two models may affect regional modes of variability, in particular those with a boundary conflict. The objective of this study is to evaluate a two-way nesting configuration that makes an interactive coupling between the RCM and the GCM, an approach against the traditional configuration of one-way nesting system. An additional aim of this work is to examine if the two-way nesting system can improve the RCM performance. The atmospheric component of the IPSL integrated climate model (LMDZ) is configured at both regional (LMDZ-regional) and global (LMDZ-global) scales. The two models have the same configuration for the dynamical framework and the physical forcings. The climatology values of sea surface temperature (SST) are prescribed for the two models. The stretched-grid of LMDZ-global is applied to a region defined by Europe, the Mediterranean, North Africa and Western North Atlantic. To ensure a good statistical significance of results, all simulations last at least 80 years. The nesting process of models is performed by a relaxation procedure of a time scale of 90 minutes. In the case of two-way nesting, the exchange between the two models is every two hours. The relaxation procedure induces a boundary conflict

  5. LOFT pressurizer safety: relief valve reliability

    Energy Technology Data Exchange (ETDEWEB)

    Brown, E.S.

    1978-01-18

    The LOFT pressurizer self-actuating safety-relief valves are constructed to the present state-of-the-art and should have reliability equivalent to the valves in use on PWR plants in the U.S. There have been no NRC incident reports on valve failures to lift that would challenge the Technical Specification Safety Limit. Fourteen valves have been reported as lifting a few percentage points outside the +-1% Tech. Spec. surveillance tolerance (9 valves tested over and 5 valves tested under specification). There have been no incident reports on failures to reseat. The LOFT surveillance program for assuring reliability is equivalent to nuclear industry practice.

  6. LOFT pressurizer safety: relief valve reliability

    International Nuclear Information System (INIS)

    Brown, E.S.

    1978-01-01

    The LOFT pressurizer self-actuating safety-relief valves are constructed to the present state-of-the-art and should have reliability equivalent to the valves in use on PWR plants in the U.S. There have been no NRC incident reports on valve failures to lift that would challenge the Technical Specification Safety Limit. Fourteen valves have been reported as lifting a few percentage points outside the +-1% Tech. Spec. surveillance tolerance (9 valves tested over and 5 valves tested under specification). There have been no incident reports on failures to reseat. The LOFT surveillance program for assuring reliability is equivalent to nuclear industry practice

  7. Bireactor Electronuclear Systems with Liquid Cadmium Valve

    CERN Document Server

    Bznuni, S A; Zhamkochyan, V M; ASosnin, A N; Polanski, A; Khudaverdyan, A H

    2002-01-01

    Three main types of bireactor electronuclear systems are discussed. From the point of view of assuring high level of functional characteristics and safety bireactor electronuclear systems with booster using enriched uranium (20 %) and with a liquid cadmium valve appears to be the most effective. It is shown by means of Monte-Carlo modeling that such operation conditions can be achieved which lead to the destruction of the intermediate cadmium layer making the systems supercritical (k_{eff}>1). One can avoid the problem by using a special design of the liquid cadmium valve. In comparison with other nuclear systems (critical reactors, one-reactor electronuclear systems) cascade electronuclear systems have essential advantages allowing the decrease of the proton beam current by one order of magnitude and providing at same time the necessary level of power generation and neutron flux. Availability of both the thermal and fast cones allows one to transmute not only transuranics but also the fission products - cesi...

  8. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  9. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    2007-01-01

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  10. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease.

    NARCIS (Netherlands)

    Yap, S.C.; Drenthen, W.; Pieper, P.G.; Moons, P.; Mulder, B.J.M.; Klieverik, L.M.; Vliegen, H.W.; Dijk, A.P.J. van; Meijboom, F.J.; Roos-Hesselink, J.W.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  11. Extrinsic mechanism obstructing the opening of a prosthetic mitral valve: an unusual case of suture entrapment.

    Science.gov (United States)

    Ozkan, Mehmet; Astarcioglu, Mehmet Ali; Karakoyun, Suleyman; Balkanay, Mehmet

    2012-02-01

    Obstruction to a prosthetic cardiac valve is a well-recognized complication of cardiac valve replacement. Malfunction of the mobile component of a prosthetic valve to open or close correctly may occur in consequence of intrinsic or extrinsic causes (thrombus, vegetation, entrapment of left ventricular myocardium, suture entanglement, and pannus formation) that may result prosthetic valve stenosis and/or insufficiency. In the case we report a 48-year-old female with valve dysfunction occurred early after surgery, as one valve leaflet was only able to partially open due to suture entrapment. © 2011, Wiley Periodicals, Inc.

  12. Behavior of one-way reinforced concrete slabs subjected to fire

    Directory of Open Access Journals (Sweden)

    Said M. Allam

    2013-12-01

    Full Text Available A finite difference analysis was performed to investigate the behavior of one-way reinforced concrete slabs exposed to fire. The objective of the study was to investigate the fire resistance and the fire risk after extinguishing the fire. Firstly, the fire resistance was obtained using the ISO834 standard fire without cooling phase. Secondly, the ISO834 parametric fire with cooling phase was applied to study the effect of cooling time. Accordingly, the critical time for cooling was identified and the corresponding failure time was calculated. Moreover, the maximum risk time which is the time between the fire extinguishing and the collapse of slab was obtained. Sixteen one-way reinforced concrete slabs were considered to study the effect of important parameters namely: the concrete cover thickness; the plaster; and the live load ratio. Equations for heat transfer through the slab thickness were used in the fire resistance calculations. Studying the cooling time revealed that the slabs are still prone to collapse although they were cooled before their fire resistance. Moreover, increasing the concrete cover thickness and the presence of plaster led to an increase in the maximum risk time. However, the variation in the live load ratio has almost no effect on such time.

  13. Recurrent pannus formation causing prosthetic aortic valve dysfunction: Is excision without valve re-replacement applicable?

    Directory of Open Access Journals (Sweden)

    Darwazah Ahmad K

    2012-06-01

    Full Text Available Abstract Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function. The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement. A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve. Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.

  14. Butterfly valve of all rubber lining type

    International Nuclear Information System (INIS)

    Shimada, Shosaku; Nakatsuma, Sumiya; Sasaki, Iwao; Aoki, Naoshi.

    1982-01-01

    The valves used for the circulating water pipes for condensers in nuclear and thermal power stations have become large with the increase of power output, and their specifications have become strict. The materials for the valves change from cast iron to steel plate construction. To cope with sea water corrosion, rubber lining has been applied to the internal surfaces of valve boxes, and the build-up welding of stainless steel has been made on the edges of valves. However, recently it is desired to develop butterfly valves, of which the whole valve disks are lined with hard rubber. For the purpose of confirming the performance of large bore valves, a 2600 mm bore butterfly valve of all rubber lining type was used, and the opening and closing test of 1100 times was carried out by applying thermal cycle and pressure difference and using artifical sea water. Also the bending test of hard rubber lining was performed with test pieces. Thus, it was confirmed that the butterfly valves of all rubber lining type have the performance exceeding that of the valves with build-up welding. The course of development of the valves of all rubber lining type, the construction and the items of confirmation by tests of these valves, and the tests of the valve and the hard rubber lining described above are reported. (Kako, I.)

  15. Supra-annular Valve-in-Valve implantation reduces blood stasis on the transcatheter aortic valve leaflets.

    Science.gov (United States)

    Vahidkhah, Koohyar; Azadani, Ali N

    2017-06-14

    Leaflet thrombosis following transcatheter aortic valve replacement (TAVR) and Valve-in-Valve (ViV) procedures has been increasingly recognized. This study aimed to investigate the effect of positioning of the transcatheter aortic valve (TAV) in ViV setting on the flow dynamics aspect of post-ViV thrombosis by quantifying the blood stasis in the intra-annular and supra-annular settings. To that end, two idealized computational models, representing ViV intra-annular and supra-annular positioning of a TAV were developed in a patient-specific geometry. Three-dimensional flow fields were then obtained via fluid-solid interaction modeling to study the difference in blood residence time (BRT) on the TAV leaflets in the two settings. At the end of diastole, a strip of high BRT (⩾1.2s) region was observed on the TAV leaflets in the ViV intra-annular positioning at the fixed boundary where the leaflets are attached to the frame. Such a high BRT region was absent on the TAV leaflets in the supra-annular positioning. The maximum value of BRT on the surface of non-, right, and left coronary leaflets of the TAV in the supra-annular positioning were 53%, 11%, and 27% smaller compared to the intra-annular positioning, respectively. It was concluded that the geometric confinement of TAV by the leaflets of the failed bioprosthetic valve in ViV intra-annular positioning increases the BRT on the leaflets and may act as a permissive factor in valvular thrombosis. The absence of such a geometric confinement in the ViV supra-annular positioning leads to smaller BRT and subsequently less likelihood of leaflet thrombosis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Resurgery for recurrent heart valve diseases

    Directory of Open Access Journals (Sweden)

    Chong-lei REN

    2017-02-01

    Full Text Available Objective To summarize the experience with resurgery for recurrent valvular heart diseases. Methods From June 2004 to June 2015, 28 patients (15 males and 13 females with ages ranging from 44 to 67 years (55.6±6.5 years with recurrent heart valve disease underwent resurgery. The reasons for resurgery included perivalvular leakage (7 cases, bioprosthetic valve decline (6 cases in mitral valve and 3 in tricuspid valve, mechanical prostheses dysfunction (2cases, infective endocarditis after valve replacement (2 cases, restenosis of repaired native valve (1 case, and severe tricuspid insufficiency after left-side valve surgery (7 cases. Resurgery included mitral valve replacement in 18 patients and tricuspid valve replacement in 10. All the patients underwent third or fourth or even fifth cardiac surgery for valve replacement. Results There were 2 hospital deaths with a mortality of 7.1% (2/28. The main causes of early-stage deaths were low cardiac output syndrome. The main postoperative complications were respiratory failure in 3, low cardiac output syndrome in 2, reexploration for bleeding in 2 and serious infectious shock in 1. All the patients were found with the great improvement in heart function and the re-implanted prostheses worked well during follow-up. Conclusions Although resurgery for recurrent heart valve disease poses a continuing challenge to cardiac surgeon, it could be performed with the satisfactory results. The keys to a successful cardiac resurgery include appropriate operational timing, refined surgical technique and reasonable perioperative managements. DOI: 10.11855/j.issn.0577-7402.2017.01.11

  17. Substitution of cobalt alloying in PWR primary circuit gate valves

    International Nuclear Information System (INIS)

    Cachon, L.; Sudreau, F.; Brunel, L.

    1995-01-01

    The object of this study is qualify cobalt-free alternative alloys for valve applications. This paper focus on tribological characterization of numerous coatings is done by using the first one, of a classical type. Then tests are performed with the second one which simulates solicitations supported by gate valves in primary circuit of PWR. 35% Ni-Cr - 65% Cr 3 C 2 coating, deposited by detonation gun technology, gives us hope to find a substitute of Stelite 6. (author). 5 refs., 16 figs., 2 tabs

  18. Experience in procurement and processing of heart valves at the Northwest Tissue Center

    International Nuclear Information System (INIS)

    Strong, M.; O'Neal, P.D.; Gage, H.N.; Moogk, M.

    1999-01-01

    The Northwest Tissue Center established a human heart valve program in 199 1. It is one of four non-profit tissue banks and one for-profit program that recover and process heart valves in the United States. During the eight years in which the Northwest Tissue Center has been involved in heart valve banking, there have been a total of 673 hearts procured for processing. The age of the donors ranged from <1 to 44 years with a mean of 26.2 years, 66% werw male,and 6.5% of the hearts procered were discarded due to a variety of medical and criteria reason. The primary reasons for differal were questions of possible cancer and questions of high risk behavior/social history. Of the 1,264 cardiovascular tissues processed, 6% were lost because of donor history, 17% were lost because of microbiology results, and 5% were lost because of donor serology . There were total a total of 190 aortic valves and 48 pulmonic conduits transplanted over this time period. The mean age of the recipients was 23.4 with a median or 23 years; 102 of the recipients were less than one year of age. Males comprised 62% of the recipients. Since 1993, there has been a clear shift towards more use of pulmonic valves over aortic valves as a results of the acceptance of the Ross procedure. Early in the program, reports were received from surgeons that some heart valves appeared to have cracks in the conduits. Experimentations in the laboratory led to the discovery that thawing too rapidly would result in cracking of these materials. Packaging was designed to reduce the rate of thawing and this has resolved the problem with cracking. The heart valve program at the Northwest Tissue Center has been very successful in providing the necessary valves for patients in the Northwest Region of the United States

  19. Left ventricular mass regression after porcine versus bovine aortic valve replacement: a randomized comparison.

    Science.gov (United States)

    Suri, Rakesh M; Zehr, Kenton J; Sundt, Thoralf M; Dearani, Joseph A; Daly, Richard C; Oh, Jae K; Schaff, Hartzell V

    2009-10-01

    It is unclear whether small differences in transprosthetic gradient between porcine and bovine biologic aortic valves translate into improved regression of left ventricular (LV) hypertrophy after aortic valve replacement. We investigated transprosthetic gradient, aortic valve orifice area, and LV mass in patients randomized to aortic valve replacement with either the Medtronic Mosaic (MM) porcine or an Edwards Perimount (EP) bovine pericardial bioprosthesis. One hundred fifty-two patients with aortic valve disease were randomly assigned to receive either the MM (n = 76) or an EP prosthesis. There were 89 men (59%), and the mean age was 76 years. Echocardiograms from preoperative, postoperative, predismissal, and 1-year time points were analyzed. Baseline characteristics and preoperative echocardiograms were similar between the two groups. The median implant size was 23 mm for both. There were no early deaths, and 10 patients (7%) died after dismissal. One hundred seven of 137 patients (78%) had a 1-year echocardiogram, and none required aortic valve reoperation. The mean aortic valve gradient at dismissal was 19.4 mm Hg (MM) versus13.5 mm Hg (EP; p regression of LV mass index (MM, -32.4 g/m(2) versus EP, -27.0 g/m(2); p = 0.40). Greater preoperative LV mass index was the sole independent predictor of greater LV mass regression after surgery (p regression of LV mass during the first year after aortic valve replacement.

  20. Mature results of a randomized trial comparing two fractionation schedules of high dose rate endoluminal brachytherapy for the treatment of endobronchial tumors

    International Nuclear Information System (INIS)

    Niemoeller, Olivier M; Pöllinger, Barbara; Niyazi, Maximilian; Corradini, Stefanie; Manapov, Farkhad; Belka, Claus; Huber, Rudolf M

    2013-01-01

    To determine the efficacy of high dose rate endobronchial brachytherapy (HDR-BT) for the treatment of centrally located lung tumors, two different fractionation schedules were compared regarding local tumor response, side effects and survival. Mature retrospective results with longer follow-up and more patients were analyzed. Initial results were published by Huber et al. in 1995. 142 patients with advanced, centrally located malignant tumors with preferential endoluminal growth were randomized to receive 4 fractions of 3.8 Gy (time interval: 1 week, n = 60, group I) or 2 fractions of 7.2 Gy (time interval: 3 weeks, n = 82, group II) endobronchial HDR-BT. Age, gender, tumor stage, Karnofsky Performance Score and histology were equally distributed between both groups. Local tumor response with 2 fractions of 7.2 Gy was significantly higher as compared to 4 fractions of 3.8 Gy (median 12 vs. 6 weeks; p ≤ 0.015). Median survival was similar in both groups (19 weeks in the 4 fractions group vs. 18 weeks in the 2 fractions group). Fatal hemoptysis was less frequent following irradiation with 2 × 7.2 Gy than with 4 × 3.8 Gy, although the difference did not achieve statistical significance (12.2% vs. 18.3%, respectively. p = 0,345). Patients presenting with squamous cell carcinoma were at higher risk of bleeding compared to other histology (21.9% vs. 9%, p = 0,035). Multivariate analysis with regard to overall survival, revealed histology (p = 0.02), Karnofsky Performance Score (p < 0.0001) and response to therapy (p < 0.0001) as significant prognostic factors. For patients showing complete response the median survival was 57 weeks, while for patients with progressive disease median survival time was 8 weeks, p < 0.0001. The KPS at the start of the treatment was significantly correlated with survival. Patients presenting with a KPS ≤ 60 at the start had a significantly (p = 0,032) shorter survival time (10 weeks) than patients with a KPS > 60 (29 weeks). Moreover

  1. Flow effects due to valve and piston motion in an internal combustion engine exhaust port

    International Nuclear Information System (INIS)

    Semlitsch, Bernhard; Wang, Yue; Mihăescu, Mihai

    2015-01-01

    Highlights: • Flow regime identification depending on the valve lift during the exhaust stroke. • Analysis of the valve motion effect onto the flow development in the exhaust port. • Physical interpretation of commonly used discharge and flow coefficient formulations. • Illustration of flow effects in junction regions with pulsatile flow. - Abstract: Performance optimization regarding e.g. exhaust valve strategies in an internal combustion engine is often performed based on one-dimensional simulation investigation. Commonly, a discharge coefficient is used to describe the flow behavior in complex geometries, such as the exhaust port. This discharge coefficient for an exhaust port is obtained by laboratory experiments at fixed valve lifts, room temperatures, and low total pressure drops. The present study investigates the consequences of the valve and piston motion onto the energy losses and the discharge coefficient. Therefore, Large Eddy Simulations are performed in a realistic internal combustion geometry using three different modeling strategies, i.e. fixed valve lift and fixed piston, moving piston and fixed valve lift, and moving piston and moving valve, to estimate the energy losses. The differences in the flow field development with the different modeling approaches is delineated and the dynamic effects onto the primary quantities, e.g. discharge coefficient, are quantified. Considering the motion of piston and valves leads to negative total pressure losses during the exhaust cycle, which cannot be observed at fixed valve lifts. Additionally, the induced flow structures develop differently when valve motion is taken into consideration, which leads to a significant disparity of mass flow rates evolving through the two individual valve ports. However, accounting for piston motion and limited valve motion, leads to a minor discharge coefficient alteration of about one to two percent

  2. Valve-stem-packing improvement study. Final report

    International Nuclear Information System (INIS)

    Adey, C.W.; Klein, J.J.

    1982-08-01

    By employing questionnaires and face-to-face interviews with valve and valve packing manufacturers, as well as nuclear plant personnel, an understanding of valve stem packing leakage problems from each of the three viewpoints was developed. This information, in-house experience, and available technical literature were used to develop specific recommendations for valve manufacturers, valve packing manufacturers, and nuclear plant valve users. It was generally recommended that each these groups make better use of graphite packing. The questionnaires and interviews indicated that increased usage of graphite packing over the last few years has reduced the incidence of valve packing problems. To confirm this, a survey of Licensee Event Reports (LERs) from 1972 to 1980 was undertaken using the keywords Valve and Packing. A statistical analysis of the LER data confirms that the adoption of graphite packing has significantly reduced valve stem leakage

  3. SEBIM pilot operated valves - CANDU and other applications

    International Nuclear Information System (INIS)

    Schaumburg, Gerald; Hera, Vlad

    1999-01-01

    The SEBIM Group, located at Chateauneuf-les-Martigues, near Marseilles, on the Mediterranean coast of France, is a market leader for the pilot operated safety relief valves in the nuclear industry. Its valves, which are subject to rigorous safety and reliability criteria, are intended to satisfy the most exigent requirements of not only the nuclear but also other demanding applications. The group manufacturing units are equipped with the state-of-the-art machinery, technical equipment and computer facilities. All personnel is highly specialized and trained. Among many applications the valves designed and manufactured by SEBIM for the biggest CANDU reactors in Canada were subjected to exceptionally difficult testing conditions, prior of being excepted by Ontario Hydro and passed all tests successfully. As a consequence Darlington N.G.S. was equipped with one of the most advanced SEBIM pressure protection piece of equipment, the Tandem Pilot Operated Pressure Relief Valve. Due to the demonstrated qualities of our product we were able to obtain the necessary registration of our valve original design with the appropriate Canadian authorities, both at the provincial level and at the federal level. One may find SEBIM protection and other type of equipment in civilian nuclear plants all over Europe as well as in military applications, like the French Navy. The SEBIM valves, covering a range between 15 mm and 160 mm diameter and capable of withstanding an inlet pressure from 2 MPa to 20 MPa and the temperature of the fluid up to 450 dec. C, are very strong competitors in the specialized field. Among these valves the tandems have special design and special qualities, for special applications. As mentioned above, two of these tandems are used, in parallel, on the Bleed Condenser vessels of the Darlington units to provide the ultimate protection of the Pressure and Inventory Control System and, through it, to the Main Heat Transfer System which is the primary cooling source

  4. Double-reed exhaust valve engine

    Science.gov (United States)

    Bennett, Charles L.

    2015-06-30

    An engine based on a reciprocating piston engine that extracts work from pressurized working fluid. The engine includes a double reed outlet valve for controlling the flow of low-pressure working fluid out of the engine. The double reed provides a stronger force resisting closure of the outlet valve than the force tending to open the outlet valve. The double reed valve enables engine operation at relatively higher torque and lower efficiency at low speed, with lower torque, but higher efficiency at high speed.

  5. The German Aortic Valve Registry (GARY): a nationwide registry for patients undergoing invasive therapy for severe aortic valve stenosis.

    Science.gov (United States)

    Beckmann, A; Hamm, C; Figulla, H R; Cremer, J; Kuck, K H; Lange, R; Zahn, R; Sack, S; Schuler, G C; Walther, T; Beyersdorf, F; Böhm, M; Heusch, G; Funkat, A K; Meinertz, T; Neumann, T; Papoutsis, K; Schneider, S; Welz, A; Mohr, F W

    2012-07-01

    aortic valve procedures in Germany joined the registry. By now, 91 sites which perform TAVI in Germany participate and more than 15,000 datasets are already in the registry.Conclusion The implementation of new or innovative medical therapies needs supervision under the conditions of a well-structured scientific project. Up to now relevant data for implementation of TAVI and long-term results are missing. In contrast to randomized controlled trials, GARY is a prospective, controlled, 5-year observational multicenter registry, and a real world investigation with only one exclusion criterion, the absence of patients' written consent. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  6. Survey of industrial coal conversion equipment capabilities: valves

    Energy Technology Data Exchange (ETDEWEB)

    Bush, W. A.; Slade, E. C.

    1978-06-01

    A survey of the industrial capabilities of the valve and valve-actuator industry to supply large, high-pressure stop valves for the future coal conversion industry is presented in this report. Also discussed are development and testing capabilities of valve and valve-actuator manufacturers and anticipated lead times required to manufacture advanced design valves for the most stringent service applications. Results indicate that the valve and valve-actuator industry is capable of manufacturing in quantity equipment of the size and for the pressure and temperature ranges which would be required in the coal conversion industry. Valve manufacturers do not, however, have sufficient product application experience to predict the continuing functional ability of valves used for lock-hopper feeders, slurry feeders, and slag-char letdown service. Developmental and testing efforts to modify existing valve designs or to develop new valve concepts for these applications were estimated to range from 1 to 6 years. A testing facility to simulate actuation of critical valves under service conditions would be beneficial.

  7. Acute Right Coronary Ostial Stenosis during Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Sarwar Umran

    2012-01-01

    Full Text Available We report a rare case of acute right coronary artery stenosis developing in a patient undergoing aortic valve replacement. We present a case report with a brief overview of the literature relating to coronary artery occlusion associated with cardiac valve surgery - the theories and treatments are discussed. A 85 year-old female was admitted under the care of the cardiothoracic team with signs and symptoms of heart failure. Investigations, including cardiac echocardiography and coronary angiography, indicated a critical aortic valve stenosis. Intraoperative right ventricular failure ensued post aortic valve replacement. Subsequent investigations revealed an acute occlusion of the proximal right coronary artery with resultant absence of distal flow supplying the right ventricle. An immediate right coronary artery bypass procedure was performed with resolution of the right ventricular failure. Subsequent weaning off cardiopulmonary bypass was uneventful and the patient continued to make excellent recovery in the postoperative phase. To our knowledge this is one of the few documented cases of intraoperative acute coronary artery occlusion developing during valve surgery. However, surgeons should be aware of the potential for acute occlusion so that early recognition and rapid intervention can be instituted.

  8. Gate valve and motor-operator research findings

    International Nuclear Information System (INIS)

    Steele, R. Jr.; DeWall, K.G.; Watkins, J.C.; Russell, M.J.; Bramwell, D.

    1995-09-01

    This report provides an update on the valve research being sponsored by the US Nuclear Regulatory Commission (NRC) and conducted at the Idaho National Engineering Laboratory (INEL). The research addresses the need to provide assurance that motor-operated valves can perform their intended safety function, usually to open or close against specified (design basis) flow and pressure loads. This report describes several important developments: Two methods for estimating or bounding the design basis stem factor (in rising-stem valves), using data from tests less severe than design basis tests; a new correlation for evaluating the opening responses of gate valves and for predicting opening requirements; an extrapolation method that uses the results of a best effort flow test to estimate the design basis closing requirements of a gate valve that exhibits atypical responses (peak force occurs before flow isolation); and the extension of the original INEL closing correlation to include low- flow and low-pressure loads. The report also includes a general approach, presented in step-by-step format, for determining operating margins for rising-stem valves (gate valves and globe valves) as well as quarter-turn valves (ball valves and butterfly valves)

  9. Valve leakage inspection testing and maintenance process

    International Nuclear Information System (INIS)

    Aikin, J.A.; Reinwald, J.W.; Kittmer, C.A.

    1991-01-01

    In valve maintenance, packing rings that prevent leakage along the valve stem must periodically be replaced, either during routine maintenance or to correct a leak or valve malfunction. Tools and procedures currently in use for valve packing removal and inspection are generally of limited value due to various access and application problems. A process has been developed by AECL Research that addresses these problems. The process, using incompressible fluid pressure, quickly and efficiently confirms the integrity of the valve backseat, extracts hard-to-remove valve packing sets, and verifies the leak tightness of the repacked valve

  10. Early Outcomes of Sutureless Aortic Valves

    Directory of Open Access Journals (Sweden)

    Muhammet Onur Hanedan

    2016-06-01

    Full Text Available Background: In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Methods: Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA valves were used. Results: The mean age of the patients was 71.15±8.60 years. Forty-four patients (67.7% were female. The average preoperative left ventricular ejection fraction was 56.9±9.93. The CPB time was 96.51±41.27 minutes and the cross-clamping time was 60.85±27.08 minutes. The intubation time was 8.95±4.19 hours, and the intensive care unit and hospital stays were 2.89±1.42 days and 7.86±1.42 days, respectively. The mean quantity of drainage from chest tubes was 407.69±149.28 mL. The hospital mortality rate was 3.1%. A total of five patients (7.69% died during follow-up. The mean follow-up time was 687.24±24.76 days. The one-year survival rate was over 90%. Conclusion: In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time.

  11. Early Outcomes of Sutureless Aortic Valves.

    Science.gov (United States)

    Hanedan, Muhammet Onur; Mataracı, İlker; Yürük, Mehmet Ali; Özer, Tanıl; Sayar, Ufuk; Arslan, Ali Kemal; Ziyrek, Uğur; Yücel, Murat

    2016-06-01

    In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR) should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB) time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy) and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA) valves were used. The mean age of the patients was 71.15±8.60 years. Forty-four patients (67.7%) were female. The average preoperative left ventricular ejection fraction was 56.9±9.93. The CPB time was 96.51±41.27 minutes and the cross-clamping time was 60.85±27.08 minutes. The intubation time was 8.95±4.19 hours, and the intensive care unit and hospital stays were 2.89±1.42 days and 7.86±1.42 days, respectively. The mean quantity of drainage from chest tubes was 407.69±149.28 mL. The hospital mortality rate was 3.1%. A total of five patients (7.69%) died during follow-up. The mean follow-up time was 687.24±24.76 days. The one-year survival rate was over 90%. In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time.

  12. Strut fracture of Björk-Shiley convexo-concave valve in Japan--risk of small valve size--.

    Science.gov (United States)

    Watarida, S; Shiraishi, S; Nishi, T; Imura, M; Yamamoto, Y; Hirokawa, R; Fujita, M

    2001-08-01

    The Björk-Shiley convexo-concave (BSCC) prosthetic valve was introduced in 1979. Between 1979 and 1986, approximately 86,000 BSCC valves were implanted. By December 31, 1994, 564 complete strut fractures had been reported to the manufacture. We experienced a case of an outlet strut fracture and investigated the risk of BSCC prosthetic valve fractures in Japan. To investigate the risk factor of a strut fracture in Japan, we investigated published cases of strut fractures. Between 1979 and 1986, 2021 BSCC valves were implanted in Japan. By January 31, 2000, 11 complete strut fractures of 60-degree BSCC valves including our case had occurred. The patients were eight males and three females. The average age at valve replacement was 42.4+/-8.1 years, and nine of eleven (81.8%) were patients valve fractured was 47.7+/-6.4 years, and eight of eleven (72.7%) were patients valve were 27 mm (n=5) (45.5%), 29 mm (n=3) (27.2%), and 31 mm (n=3) (27.2%). Four patients died and seven patients survived. Although only 11 BSCC valve struts fractured and statistical analysis could not be performed, our findings suggest that the high risk group for a strut fracture in Japan is young male patients with a mitral valve, >= 27 mm in size with BSCC models manufactured before March 1982. When following-up patients with BSCC models manufactured before March 1982, the possibility of a strut fracture in all BSCC valve sizes should be kept in mind.

  13. [Reoperative valve replacement in patients undergoing cardiac reoperation: a report of 104 cases].

    Science.gov (United States)

    Zou, Liang-jian; Xu, Zhi-yun; Wang, Zhi-nong; Lang, Xi-long; Han, Lin; Lu, Fang-lin; Xu, Ji-bin; Tang, Hao; Ji, Guang-yu; Wang, Er-song; Wang, Jun; Qu, Yi

    2010-08-15

    To review the experience of reoperative valve replacement for 104 patients. From January 2002 to December 2009, 104 patients underwent heart valve replacement in reoperations, accounting for 2.92% of the total patient population (3557 cases) who had valve replacement during this period. In this group, 53 male and 51 female patients were included with a median age of 46 years (ranged from 13 to 72 years). The reasons of reoperation included 28 cases suffered from another valve lesion after valve replacement, 10 cases suffered from valve lesion after mitral valvuloplasty, 19 cases suffered from perivalvular leakage after valve replacement, 18 cases suffered from valve lesion after previous correction of congenital heart defect, 7 cases suffered from bioprosthetic valve decline, 10 cases suffered from prosthetic valve endocarditis, 9 cases suffered from dysfunction of machine valve, and 3 cases suffered from other causes. The re-operations were mitral and aortic valve replacement in 2 cases, mitral valve replacement in 59 cases, aortic valve replacement in 24 cases, tricuspid valve replacement in 16 cases, and Bentall's operation in 3 cases. The interval from first operation to next operation was 1 month-19 years. There were 8 early deaths from heart failure, renal failure and multiple organ failure (early mortality 7.69%). Major complications were intraoperative hemorrhage in 2 cases, re-exploration for mediastinal bleeding in 2 cases and sternotomy surgical site infection in 1 case. Complete follow-up (3 months-7 years and 2 months) was available for all patients. Two patients died, one patient died of intracranial hemorrhage, and another cause was unknown. Satisfactory short-term and long-term results can be obtained in reoperative valve replacement with appropriate timing of operation control, satisfactory myocardial protection, accurate surgical procedure and suitable perioperative treatment.

  14. Biological aortic valve replacement: advantages and optimal indications of stentless compared to stented valve substitutes. A review.

    Science.gov (United States)

    Tavakoli, Reza; Danial, Pichoy; Oudjana, Ahmed Hamid; Jamshidi, Peiman; Gassmann, Max; Leprince, Pascal; Lebreton, Guillaume

    2018-05-01

    Controversy still surrounds the optimal biological valve substitute for aortic valve replacement. In light of the current literature, we review advantages and optimal indications of stentless compared to stented aortic bio-prostheses. Recent meta-analyses, prospective randomized controlled trials and retrospective studies comparing the most frequently used stentless and stented aortic bio-prostheses were analyzed. In the present review, the types and implantation techniques of the bio-prosthesis that are seldom taken into account by most studies and reviews were integrated in the interpretation of the relevant reports. For stentless aortic root bio-prostheses, full-root vs. sub-coronary implantation offered better early transvalvular gradients, effective orifice area and left ventricular mass regression as well as late freedom from structural valve deterioration in retrospective studies. Early mortality and morbidity did not differ between the stentless and stented aortic bio-prostheses. Early transvalvular gradients, effective orifice area and regression of left ventricular hypertrophy were significantly better for stentless, especially as full-root, compared to stented bio-prostheses. The long-term valve-related survival for stentless aortic root and Toronto SPV bio-prosthesis was as good as that for stented pericardial aortic bio-prostheses. For full-root configuration this survival advantage was statistically significant. There seems to be not one but different ideal biological valve substitutes for different subgroups of patients. In patients with small aortic root or exposed to prosthesis-patient mismatch full-root implantation of stentless bio-prostheses may better meet functional needs of individual patients. Longer follow-ups on newer generation of stented bio-prostheses are needed for comparison of their hemodynamic performance with stentless counterparts especially in full-root configuration.

  15. Defect in mitochondrial functions in damaged human mitral valve

    OpenAIRE

    Shinde, Santosh; Kumar, Pawan; Mishra, Kaushala; Patil, Neela

    2006-01-01

    Mitochondrial diseases are a heterogeneous group of disorders in which a primary mitochondrial dysfunction is proven by morphological, biochemical, and genetic examinations. The mitral valve has important function in the regulation of blood flow from one chamber to another. Often, the mitral valve becomes abnormal with age, in Rheumatic fever or it is abnormal from birth (Congenital) or it can be destroyed by infection i.e. bacterial endocarditis and needs replacement. Myocardial function dep...

  16. Guidelines for valves in tritium service

    International Nuclear Information System (INIS)

    Weaver, W.W.

    1994-01-01

    Some undesirable practices and misapplications that caused valve-related failures are examined, and future courses of action are recommended to avoid repetition of these events. Desirable valve characteristics and practices that should be considered when selecting valves for use in tritium service are also discussed. Supporting logic for the desirability of these features is presented by discussing the mechanisms of valve degradation followed by examples of related events. Desirable valve and system features and operational actions are grouped into two categories: strongly recommended and recommended. 13 refs., 1 fig

  17. Endobronchial Ultrasound Reliably Quantifies Airway Smooth Muscle Remodeling in an Equine Asthma Model.

    Directory of Open Access Journals (Sweden)

    Michela Bullone

    Full Text Available Endobronchial ultrasonography (EBUS revealed differences in the thickness of the layer representing subepithelial tissues (L2 between human asthmatics and controls, but whether this measurement correlates with airway smooth muscle (ASM remodeling in asthma is unknown. In this study, we sought to determine the ability of EBUS to predict histological ASM remodeling in normal and equine asthmatic airways. We studied 109 isolated bronchi from the lungs of 13 horses. They underwent EBUS examination using a 30 MHz radial probe before being processed for histology. ASM remodeling parameters were evaluated in EBUS images (L2 thickness, L2 area, L2 area/internal perimeter [Pi] and L2 area/Pi2 and histological cuts (ASM area/Pi2, and compared. EBUS was then performed ex vivo on the lungs of 4 horses with heaves, an asthma-like condition of horses, and 7 controls to determine whether central bronchial remodeling could be detected with this technique. An optimized approach was developed based on data variability within airways, subjects, and groups, and then validated in 7 horses (3 controls, 4 with heaves that underwent EBUS in vivo. L2 area was significantly associated to ASM area in isolated lungs (p<0.0001, in the absence of significant bias related to the airway size. Bronchial size significantly affected EBUS ASM-related parameters, except for L2 area/Pi2. L2 area/Pi2 was increased in the airways of asthmatic horses compared to controls, both ex vivo and in vivo (p<0.05. Bronchial histology confirmed our findings (AASM/Pi2 was increased in asthmatic horses compared to controls, p<0.05. In both horses with heaves and controls, L2 was composed of ASM for the outer 75% of its thickness and by ECM for the remaining inner 25%. In conclusion, EBUS reliably allows assessment of asthma-associated ASM remodeling of central airways in a non-invasive way.

  18. The SNS Resonance Control Cooling System Control Valve Upgrade Performance

    International Nuclear Information System (INIS)

    Williams, Derrick C.; Schubert, James Phillip; Tang, Johnny Y.

    2008-01-01

    The normal-conducting linac of the Spallation Neutron Source (SNS) uses 10 separate Resonance Control Cooling System (RCCS) water skids to control the resonance of 6 Drift Tube Linac (DTL) and 4 Coupled Cavity Linac (CCL) accelerating structures. The RCCS water skids use 2 control valves; one to regulate the chilled water flow and the other to bypass water to a chilled water heat exchanger. These valves have hydraulic actuators that provide position and feedback to the control system. Frequency oscillations occur using these hydraulic actuators due to their coarse movement and control of the valves. New pneumatic actuator and control positioners have been installed on the DTL3 RCCS water skid to give finer control and regulation of DTL3 cavity temperature. This paper shows a comparison of resonance control performance for the two valve configurations.

  19. One Way Forward to Beat the Newtonian Habit with a Complexity Perspective on Organisational Change

    Directory of Open Access Journals (Sweden)

    Josie McLean

    2013-10-01

    Full Text Available We face a global crisis of un-sustainability—we need to change trajectory, but have so far displayed a collective inability to do so. This article suggests that one reason for this is our entrenched approach to change, which has inappropriately applied mechanistic Newtonian assumptions to “living” systems. Applying what has been learned about the behaviour of complex adaptive systems, we develop a pragmatic model for students of sustainability, who want to facilitate profound organizational and community change towards sustainability on the ground. Our model, “one way forward”, does not purport to be the only way but one possibility, grounded in a different understanding of the nature and dynamic of change as seen through the lens of complexity. In this way, it challenges more conventional change management practices. One way forward is a model facilitating evolutionary change in a social ecology—one possible expression of a “culture of community self-design” as expressed by Banathy. Its theoretical foundations and its practical application (it is designed for practice both have their source in a systemic view and in the principles that reflect the paradigm of complexity. Four central components of this new model—envisioning, core messages (values, indicators of progress, and experimentation—are explored in more detail.

  20. Semi-device-independent security of one-way quantum key distribution

    OpenAIRE

    Pawlowski, Marcin; Brunner, Nicolas

    2011-01-01

    By testing nonlocality, the security of entanglement-based quantum key distribution (QKD) can be enhanced to being 'device-independent'. Here we ask whether such a strong form of security could also be established for one-way (prepare and measure) QKD. While fully device-independent security is impossible, we show that security can be guaranteed against individual attacks in a semi-device-independent scenario. In the latter, the devices used by the trusted parties are non-characterized, but t...