WorldWideScience

Sample records for encoded optical voltage

  1. Modulating the Voltage-sensitivity of a Genetically Encoded Voltage Indicator.

    Science.gov (United States)

    Jung, Arong; Rajakumar, Dhanarajan; Yoon, Bong-June; Baker, Bradley J

    2017-10-01

    Saturation mutagenesis was performed on a single position in the voltage-sensing domain (VSD) of a genetically encoded voltage indicator (GEVI). The VSD consists of four transmembrane helixes designated S1-S4. The V220 position located near the plasma membrane/extracellular interface had previously been shown to affect the voltage range of the optical signal. Introduction of polar amino acids at this position reduced the voltage-dependent optical signal of the GEVI. Negatively charged amino acids slightly reduced the optical signal by 33 percent while positively charge amino acids at this position reduced the optical signal by 80%. Surprisingly, the range of V220D was similar to that of V220K with shifted optical responses towards negative potentials. In contrast, the V220E mutant mirrored the responses of the V220R mutation suggesting that the length of the side chain plays in role in determining the voltage range of the GEVI. Charged mutations at the 219 position all behaved similarly slightly shifting the optical response to more negative potentials. Charged mutations to the 221 position behaved erratically suggesting interactions with the plasma membrane and/or other amino acids in the VSD. Introduction of bulky amino acids at the V220 position increased the range of the optical response to include hyperpolarizing signals. Combining The V220W mutant with the R217Q mutation resulted in a probe that reduced the depolarizing signal and enhanced the hyperpolarizing signal which may lead to GEVIs that only report neuronal inhibition.

  2. Electro-optical voltage transformer

    Science.gov (United States)

    Xu, Yan; Ye, Miaoyuan; Cui, Ying

    1999-02-01

    The work introduces an optical fiber voltage transformer based on the Pockels effect. The transformer is different from a conventional electric-magnetic voltage transformer. A crystal BGO is used as sensor that is sealed in SF6 gas container; the measured signal is transferred by optical fiber in the Electro-Optical Voltage Transformer (EOVT). The principles and composition of EOVT is described here. The system consists of three parts: capacitive divider, optical sensor and electronics module. According to the analysis of factors that influence on the accuracy of measurement, the main ones, temperature and pressure of SF6, are corrected by means of signal digital process. The performances of 110kV EOVT were tested. The results show that the accuracy of EOVT could achieve 0.5 percent. Compared to a conventional electric-magnetic voltage transformer, the advantages of 110kV EOVT are higher accuracy, low cost, small volume, excellent dynamic characteristics and immunity from electromagnetic interference. In particular the low voltage is effectively isolated from the high voltage by means of the optical fiber.

  3. Synthesis of extended nanoscale optical encoders.

    Science.gov (United States)

    Wickersham, Charles E; Kerr, Daniel H S; Lipman, Everett A

    2010-12-15

    An optical encoder is a device that uses an interrupted light source-sensor pair to map linear or rotational motion onto a periodic signal. Simple, inexpensive optical encoders are used for precise positioning in machines such as desktop printers, disk drives, and astronomical telescopes. A strand of DNA labeled with a series of Förster resonance energy transfer acceptor dyes can perform the same function at the nanometer scale, producing a periodic fluorescence signal that encodes the movement of a single donor-labeled molecular motor with high spatial and temporal resolution. Previous measurements of this type have employed encoders limited to five acceptor dyes, and hence five signal periods, restricting the range of motion that could be followed. Here we describe two methods for synthesizing double-stranded DNA containing several to hundreds of regularly spaced dyes on one strand. Distinct functional groups incorporated at the encoder ends enable tethering for single-molecule measurements.

  4. Engineering of a genetically encodable fluorescent voltage sensor exploiting fast Ci-VSP voltage-sensing movements

    DEFF Research Database (Denmark)

    Lundby, Alicia; Mutoh, Hiroki; Dimitrov, Dimitar

    2008-01-01

    Ci-VSP contains a voltage-sensing domain (VSD) homologous to that of voltage-gated potassium channels. Using charge displacement ('gating' current) measurements we show that voltage-sensing movements of this VSD can occur within 1 ms in mammalian membranes. Our analysis lead to development of a g...... of a genetically encodable fluorescent protein voltage sensor (VSFP) in which the fast, voltage-dependent conformational changes of the Ci-VSP voltage sensor are transduced to similarly fast fluorescence read-outs....

  5. Fast two-photon imaging of subcellular voltage dynamics in neuronal tissue with genetically encoded indicators.

    Science.gov (United States)

    Chamberland, Simon; Yang, Helen H; Pan, Michael M; Evans, Stephen W; Guan, Sihui; Chavarha, Mariya; Yang, Ying; Salesse, Charleen; Wu, Haodi; Wu, Joseph C; Clandinin, Thomas R; Toth, Katalin; Lin, Michael Z; St-Pierre, François

    2017-07-27

    Monitoring voltage dynamics in defined neurons deep in the brain is critical for unraveling the function of neuronal circuits but is challenging due to the limited performance of existing tools. In particular, while genetically encoded voltage indicators have shown promise for optical detection of voltage transients, many indicators exhibit low sensitivity when imaged under two-photon illumination. Previous studies thus fell short of visualizing voltage dynamics in individual neurons in single trials. Here, we report ASAP2s, a novel voltage indicator with improved sensitivity. By imaging ASAP2s using random-access multi-photon microscopy, we demonstrate robust single-trial detection of action potentials in organotypic slice cultures. We also show that ASAP2s enables two-photon imaging of graded potentials in organotypic slice cultures and in Drosophila . These results demonstrate that the combination of ASAP2s and fast two-photon imaging methods enables detection of neural electrical activity with subcellular spatial resolution and millisecond-timescale precision.

  6. Voltage-programmable liquid optical interface

    Science.gov (United States)

    Brown, C. V.; Wells, G. G.; Newton, M. I.; McHale, G.

    2009-07-01

    Recently, there has been intense interest in photonic devices based on microfluidics, including displays and refractive tunable microlenses and optical beamsteerers that work using the principle of electrowetting. Here, we report a novel approach to optical devices in which static wrinkles are produced at the surface of a thin film of oil as a result of dielectrophoretic forces. We have demonstrated this voltage-programmable surface wrinkling effect in periodic devices with pitch lengths of between 20 and 240 µm and with response times of less than 40 µs. By a careful choice of oils, it is possible to optimize either for high-amplitude sinusoidal wrinkles at micrometre-scale pitches or more complex non-sinusoidal profiles with higher Fourier components at longer pitches. This opens up the possibility of developing rapidly responsive voltage-programmable, polarization-insensitive transmission and reflection diffraction devices and arbitrary surface profile optical devices.

  7. Shift-encoded optically multiplexed imaging

    Science.gov (United States)

    Shah, Vinay; Rachlin, Yaron; Shepard, R. Hamilton; Shih, Tina

    2017-04-01

    In a multiplexed image, multiple fields-of-view (FoVs) are superimposed onto a common focal plane. The attendant gain in sensor FoV provides a new degree of freedom in the design of an imaging system, allowing for performance tradeoffs not available in traditional optical designs. We explore design choices relating to a shift-encoded optically multiplexed imaging system and discuss their performance implications. Unlike in a traditional imaging system, a single multiplexed image has a fundamental ambiguity regarding the location of objects in the image. We present a system that can shift each FoV independently to break this ambiguity and compare it to other potential disambiguation techniques. We then discuss the optical, mechanical, and encoding design choices of a shift-encoding midwave infrared imaging system that multiplexes six 15×15 deg FoVs onto a single one megapixel focal plane. Using this sensor, we demonstrate a computationally demultiplexed wide FoV video.

  8. Method for high-speed Manchester encoded optical signal generation

    DEFF Research Database (Denmark)

    Zhang, Jianfeng; Chi, Nan; Holm-Nielsen, Pablo Villanueva

    2004-01-01

    A method for high-speed Manchester encoded optical signal generation is proposed and demonstrated with a specially configured electro-optical modulator. A 10 Gb/s Manchester encoded optical signal was generated, and its bit-error-ratio (BER) performance was evaluated.......A method for high-speed Manchester encoded optical signal generation is proposed and demonstrated with a specially configured electro-optical modulator. A 10 Gb/s Manchester encoded optical signal was generated, and its bit-error-ratio (BER) performance was evaluated....

  9. A Fluorescent, Genetically-Encoded Voltage Probe Capable of Resolving Action Potentials: e43454

    National Research Council Canada - National Science Library

    Lauren Barnett; Jelena Platisa; Marko Popovic; Vincent A Pieribone; Thomas Hughes

    2012-01-01

      There is a pressing need in neuroscience for genetically-encoded, fluorescent voltage probes that can be targeted to specific neurons and circuits to allow study of neural activity using fluorescent imaging...

  10. A fluorescent, genetically-encoded voltage probe capable of resolving action potentials

    National Research Council Canada - National Science Library

    Barnett, Lauren; Platisa, Jelena; Popovic, Marko; Pieribone, Vincent A; Hughes, Thomas

    2012-01-01

    There is a pressing need in neuroscience for genetically-encoded, fluorescent voltage probes that can be targeted to specific neurons and circuits to allow study of neural activity using fluorescent imaging...

  11. A Fluorescent, Genetically-Encoded Voltage Probe Capable of Resolving Action Potentials

    OpenAIRE

    Lauren Barnett; Jelena Platisa; Marko Popovic; Pieribone, Vincent A.; Thomas Hughes

    2012-01-01

    There is a pressing need in neuroscience for genetically-encoded, fluorescent voltage probes that can be targeted to specific neurons and circuits to allow study of neural activity using fluorescent imaging. We created 90 constructs in which the voltage sensing portion (S1-S4) of Ciona intestinalis voltage sensitive phosphatase (CiVSP) was fused to circularly permuted eGFP. This led to ElectricPk, a probe that is an order of magnitude faster (taus ~1-2 ms) than any currently published fluores...

  12. Rapid Cellular Phenotyping of Human Pluripotent Stem Cell-Derived Cardiomyocytes using a Genetically Encoded Fluorescent Voltage Sensor

    Directory of Open Access Journals (Sweden)

    Jordan S. Leyton-Mange

    2014-02-01

    Full Text Available In addition to their promise in regenerative medicine, pluripotent stem cells have proved to be faithful models of many human diseases. In particular, patient-specific stem cell-derived cardiomyocytes recapitulate key features of several life-threatening cardiac arrhythmia syndromes. For both modeling and regenerative approaches, phenotyping of stem cell-derived tissues is critical. Cellular phenotyping has largely relied upon expression of lineage markers rather than physiologic attributes. This is especially true for cardiomyocytes, in part because electrophysiological recordings are labor intensive. Likewise, most optical voltage indicators suffer from phototoxicity, which damages cells and degrades signal quality. Here we present the use of a genetically encoded fluorescent voltage indicator, ArcLight, which we demonstrate can faithfully report transmembrane potentials in human stem cell-derived cardiomyocytes. We demonstrate the application of this fluorescent sensor in high-throughput, serial phenotyping of differentiating cardiomyocyte populations and in screening for drug-induced cardiotoxicity.

  13. Negative base encoding in optical linear algebra processors

    Science.gov (United States)

    Perlee, C.; Casasent, D.

    1986-01-01

    In the digital multiplication by analog convolution algorithm, the bits of two encoded numbers are convolved to form the product of the two numbers in mixed binary representation; this output can be easily converted to binary. Attention is presently given to negative base encoding, treating base -2 initially, and then showing that the negative base system can be readily extended to any radix. In general, negative base encoding in optical linear algebra processors represents a more efficient technique than either sign magnitude or 2's complement encoding, when the additions of digitally encoded products are performed in parallel.

  14. An optical fiber Bragg grating and piezoelectric ceramic voltage sensor

    Science.gov (United States)

    Yang, Qing; He, Yanxiao; Sun, Shangpeng; Luo, Mandan; Han, Rui

    2017-10-01

    Voltage measurement is essential in many fields like power grids, telecommunications, metallurgy, railways, and oil production. A voltage-sensing unit, consisting of fiber Bragg gratings (FBGs) and piezoelectric ceramics, based on which an optical over-voltage sensor was proposed and fabricated in this paper. No demodulation devices like spectrometer or Fabry-Perot filter were needed to gain the voltage signal, and a relatively large sensing frequency range was acquired in this paper; thus, the cost of the sensing system is more acceptable in engineering application. The voltage to be measured was directly applied to the piezoelectric ceramic, and deformation of the ceramics and the grating would be caused because of the inverse piezoelectric effect. With a reference grating, the output light intensity change will be caused by the FBG center wavelength change; thus, the relationship between the applied voltage and the output light intensity was established. Validation of the sensor was accomplished in the frequency range from 50 Hz to 20 kHz and switching impulse waves with a test platform; good linearity of the input-output characteristic was achieved. A temperature validation test was completed, showing that the sensor maintains good temperature stability. Experimental results show that the optical over-voltage sensor can be used for voltage monitoring, and if applied with a voltage divider, the sensor can be used to measure high voltage.

  15. An optical fiber Bragg grating and piezoelectric ceramic voltage sensor.

    Science.gov (United States)

    Yang, Qing; He, Yanxiao; Sun, Shangpeng; Luo, Mandan; Han, Rui

    2017-10-01

    Voltage measurement is essential in many fields like power grids, telecommunications, metallurgy, railways, and oil production. A voltage-sensing unit, consisting of fiber Bragg gratings (FBGs) and piezoelectric ceramics, based on which an optical over-voltage sensor was proposed and fabricated in this paper. No demodulation devices like spectrometer or Fabry-Perot filter were needed to gain the voltage signal, and a relatively large sensing frequency range was acquired in this paper; thus, the cost of the sensing system is more acceptable in engineering application. The voltage to be measured was directly applied to the piezoelectric ceramic, and deformation of the ceramics and the grating would be caused because of the inverse piezoelectric effect. With a reference grating, the output light intensity change will be caused by the FBG center wavelength change; thus, the relationship between the applied voltage and the output light intensity was established. Validation of the sensor was accomplished in the frequency range from 50 Hz to 20 kHz and switching impulse waves with a test platform; good linearity of the input-output characteristic was achieved. A temperature validation test was completed, showing that the sensor maintains good temperature stability. Experimental results show that the optical over-voltage sensor can be used for voltage monitoring, and if applied with a voltage divider, the sensor can be used to measure high voltage.

  16. An Improved Linearization Circuit Used for Optical Rotary Encoders

    National Research Council Canada - National Science Library

    Jelena Jovanović; Dragan Denić; Uglješa Jovanović

    2017-01-01

    .... To improve the optical encoder sensitivity and to increase its accuracy, an improved linearization circuit based on pseudo-linear signal generation and its further linearization with the two-stage...

  17. A new methodology for vibration error compensation of optical encoders

    National Research Council Canada - National Science Library

    Lopez, Jesus; Artes, Mariano

    2012-01-01

    Optical encoders are sensors based on grating interference patterns. Tolerances inherent to the manufacturing process can induce errors in the position accuracy as the measurement signals stand apart from the ideal conditions...

  18. A New Methodology for Vibration Error Compensation of Optical Encoders

    OpenAIRE

    Mariano Artes; Jesus Lopez

    2012-01-01

    Optical encoders are sensors based on grating interference patterns. Tolerances inherent to the manufacturing process can induce errors in the position accuracy as the measurement signals stand apart from the ideal conditions. In case the encoder is working under vibrations, the oscillating movement of the scanning head is registered by the encoder system as a displacement, introducing an error into the counter to be added up to graduation, system and installation errors. Behavior improvement...

  19. Development of a reflective optical encoder with submicron accuracy

    Science.gov (United States)

    Ye, Guoyong; Liu, Hongzhong; Ban, Yaowen; Shi, Yongsheng; Yin, Lei; Lu, Bingheng

    2018-03-01

    Signal distortion is a key issue that limits the measurement resolution and accuracy of optical encoders. In this paper, an optical encoder based on generalized grating imaging using a two-dimensional index grating is presented. The general expression of intensity distribution for generalized grating imaging including the relative displacement between the scale grating and the reading head is derived, and the formation of the signal distortion of the optical encoder is analyzed. Then, a two-dimensional index grating, which consists of multiple grating tracks with defined offsets, is proposed to suppress the dominant third and fifth order harmonic signals. The operating principle of the two-dimensional index grating is explained in detail and a reflective optical encoder is developed. In the experiment, approximately ideal Lissajous figure of the encoder signals is obtained. Fourier analysis of the encoder signals shows that both the third and fifth order harmonic distortions are below 0.6%. Experimental results show that the interpolation error of the optical encoder is within ± 0 . 18 μm, and the accuracy is better than ± 0 . 3 μm over 255 mm travel range with a maximum variation of 0.136 μm.

  20. Ultra High Voltage Surge Waveforms Measurement Using an Optical Transducer

    Directory of Open Access Journals (Sweden)

    Francisco G. PEÑA-LECONA

    2010-05-01

    Full Text Available Ultra high voltage surge waveforms measurement by means of a portable optical transducer is presented. The sensor system uses a transducer element based on the longitudinal electro-optic effect with a double pass configuration to obtain a better sensitivity. The transducer head is allocated to one meter of distance from the generating element of electric field and it is able to measure waveform surges from 515 kV up to 1090 kV with fast response. It is demonstrated that the telemetry of ultra high voltage surge waveforms can be successfully done by means of this proposed optical transducer.

  1. A fluorescent, genetically-encoded voltage probe capable of resolving action potentials.

    Science.gov (United States)

    Barnett, Lauren; Platisa, Jelena; Popovic, Marko; Pieribone, Vincent A; Hughes, Thomas

    2012-01-01

    There is a pressing need in neuroscience for genetically-encoded, fluorescent voltage probes that can be targeted to specific neurons and circuits to allow study of neural activity using fluorescent imaging. We created 90 constructs in which the voltage sensing portion (S1-S4) of Ciona intestinalis voltage sensitive phosphatase (CiVSP) was fused to circularly permuted eGFP. This led to ElectricPk, a probe that is an order of magnitude faster (taus ~1-2 ms) than any currently published fluorescent protein-based voltage probe. ElectricPk can follow the rise and fall of neuronal action potentials with a modest decrease in fluorescence intensity (~0.7% ΔF/F). The probe has a nearly linear fluorescence/membrane potential response to both hyperpolarizing and depolarizing steps. This is the first probe based on CiVSP that captures the rapid movements of the voltage sensor, suggesting that voltage probes designed with circularly permuted fluorescent proteins may have some advantages.

  2. A fluorescent, genetically-encoded voltage probe capable of resolving action potentials.

    Directory of Open Access Journals (Sweden)

    Lauren Barnett

    Full Text Available There is a pressing need in neuroscience for genetically-encoded, fluorescent voltage probes that can be targeted to specific neurons and circuits to allow study of neural activity using fluorescent imaging. We created 90 constructs in which the voltage sensing portion (S1-S4 of Ciona intestinalis voltage sensitive phosphatase (CiVSP was fused to circularly permuted eGFP. This led to ElectricPk, a probe that is an order of magnitude faster (taus ~1-2 ms than any currently published fluorescent protein-based voltage probe. ElectricPk can follow the rise and fall of neuronal action potentials with a modest decrease in fluorescence intensity (~0.7% ΔF/F. The probe has a nearly linear fluorescence/membrane potential response to both hyperpolarizing and depolarizing steps. This is the first probe based on CiVSP that captures the rapid movements of the voltage sensor, suggesting that voltage probes designed with circularly permuted fluorescent proteins may have some advantages.

  3. Encoded diffractive optics for full-spectrum computational imaging

    KAUST Repository

    Heide, Felix

    2016-09-16

    Diffractive optical elements can be realized as ultra-thin plates that offer significantly reduced footprint and weight compared to refractive elements. However, such elements introduce severe chromatic aberrations and are not variable, unless used in combination with other elements in a larger, reconfigurable optical system. We introduce numerically optimized encoded phase masks in which different optical parameters such as focus or zoom can be accessed through changes in the mechanical alignment of a ultra-thin stack of two or more masks. Our encoded diffractive designs are combined with a new computational approach for self-calibrating imaging (blind deconvolution) that can restore high-quality images several orders of magnitude faster than the state of the art without pre-calibration of the optical system. This co-design of optics and computation enables tunable, full-spectrum imaging using thin diffractive optics.

  4. Method and apparatus for optical encoding with compressible imaging

    Science.gov (United States)

    Leviton, Douglas B. (Inventor)

    2006-01-01

    The present invention presents an optical encoder with increased conversion rates. Improvement in the conversion rate is a result of combining changes in the pattern recognition encoder's scale pattern with an image sensor readout technique which takes full advantage of those changes, and lends itself to operation by modern, high-speed, ultra-compact microprocessors and digital signal processors (DSP) or field programmable gate array (FPGA) logic elements which can process encoder scale images at the highest speeds. Through these improvements, all three components of conversion time (reciprocal conversion rate)--namely exposure time, image readout time, and image processing time--are minimized.

  5. Unidirectional Manchester Encoded Data Transfer via a Fiber Optic Link

    Science.gov (United States)

    1988-03-01

    The subject of this thesis is the application of Manchester coding techniques to digital data transfer . Asynchronous receipt of digital data for...necessary hardware to allow Manchester encoded data transfer over a fiber optic data link. The scope of the project was limited to the transfer of byte

  6. A new methodology for vibration error compensation of optical encoders.

    Science.gov (United States)

    Lopez, Jesus; Artes, Mariano

    2012-01-01

    Optical encoders are sensors based on grating interference patterns. Tolerances inherent to the manufacturing process can induce errors in the position accuracy as the measurement signals stand apart from the ideal conditions. In case the encoder is working under vibrations, the oscillating movement of the scanning head is registered by the encoder system as a displacement, introducing an error into the counter to be added up to graduation, system and installation errors. Behavior improvement can be based on different techniques trying to compensate the error from measurement signals processing. In this work a new "ad hoc" methodology is presented to compensate the error of the encoder when is working under the influence of vibration. The methodology is based on fitting techniques to the Lissajous figure of the deteriorated measurement signals and the use of a look up table, giving as a result a compensation procedure in which a higher accuracy of the sensor is obtained.

  7. A New Methodology for Vibration Error Compensation of Optical Encoders

    Directory of Open Access Journals (Sweden)

    Mariano Artes

    2012-04-01

    Full Text Available Optical encoders are sensors based on grating interference patterns. Tolerances inherent to the manufacturing process can induce errors in the position accuracy as the measurement signals stand apart from the ideal conditions. In case the encoder is working under vibrations, the oscillating movement of the scanning head is registered by the encoder system as a displacement, introducing an error into the counter to be added up to graduation, system and installation errors. Behavior improvement can be based on different techniques trying to compensate the error from measurement signals processing. In this work a new “ad hoc” methodology is presented to compensate the error of the encoder when is working under the influence of vibration. The methodology is based on fitting techniques to the Lissajous figure of the deteriorated measurement signals and the use of a look up table, giving as a result a compensation procedure in which a higher accuracy of the sensor is obtained.

  8. Optically triggered high voltage switch network and method for switching a high voltage

    Science.gov (United States)

    El-Sharkawi, Mohamed A.; Andexler, George; Silberkleit, Lee I.

    1993-01-19

    An optically triggered solid state switch and method for switching a high voltage electrical current. A plurality of solid state switches (350) are connected in series for controlling electrical current flow between a compensation capacitor (112) and ground in a reactive power compensator (50, 50') that monitors the voltage and current flowing through each of three distribution lines (52a, 52b and 52c), which are supplying three-phase power to one or more inductive loads. An optical transmitter (100) controlled by the reactive power compensation system produces light pulses that are conveyed over optical fibers (102) to a switch driver (110') that includes a plurality of series connected optical triger circuits (288). Each of the optical trigger circuits controls a pair of the solid state switches and includes a plurality of series connected resistors (294, 326, 330, and 334) that equalize or balance the potential across the plurality of trigger circuits. The trigger circuits are connected to one of the distribution lines through a trigger capacitor (340). In each switch driver, the light signals activate a phototransistor (300) so that an electrical current flows from one of the energy reservoir capacitors through a pulse transformer (306) in the trigger circuit, producing gate signals that turn on the pair of serially connected solid state switches (350).

  9. Potassium Sensitive Optical Nanosensors Containing Voltage Sensitive Dyes.

    Science.gov (United States)

    Xie, Xiaojiang; Gutiérrez, Agustín; Trofimov, Valentin; Szilagyi, Istvan; Soldati, Thierry; Bakker, Eric

    2015-01-01

    lonophore-based ion-selective optical nanosensors have been explored for a number of years. Voltage sensitive dyes (VSDs) have been introduced into this type of sensors only very recently, forming a new class of analytical tools. Here, K(+)-sensitive nanospheres incorporating a lipophilic VSD were successfully fabricated and characterized. The nanosensors were readily delivered into the social amoeba Dictyostelium discoideum in a non-invasive manner, forming a promising new platform for intracellular ion quantification and imaging.

  10. Optical fiber voltage sensors for broad temperature ranges

    Science.gov (United States)

    Rose, A. H.; Day, G. W.

    1992-01-01

    We describe the development of an optical fiber ac voltage sensor for aircraft and spacecraft applications. Among the most difficult specifications to meet for this application is a temperature stability of +/- 1 percent from -65 C to +125 C. This stability requires a careful selection of materials, components, and optical configuration with further compensation using an optical-fiber temperature sensor located near the sensing element. The sensor is a polarimetric design, based on the linear electro-optic effect in bulk Bi4Ge3O12. The temperature sensor is also polarimetric, based on the temperature dependence of the birefringence of bulk SiO2. The temperature sensor output is used to automatically adjust the calibration of the instrument.

  11. An Improved Linearization Circuit Used for Optical Rotary Encoders

    Science.gov (United States)

    Jovanović, Jelena; Denić, Dragan; Jovanović, Uglješa

    2017-10-01

    Optical rotary encoders generate nonlinear sine and cosine signals in response to a change of angular position that is being measured. Due to the nonlinear shape of encoder output signals, encoder sensitivity to very small changes of angular position is low, causing a poor measurement accuracy level. To improve the optical encoder sensitivity and to increase its accuracy, an improved linearization circuit based on pseudo-linear signal generation and its further linearization with the two-stage piecewise linear analog-to-digital converter is presented in this paper. The proposed linearization circuit is composed of a mixed-signal circuit, which generates analog pseudo-linear signal and determines the first four bits of the final digital result, and the two-stage piecewise linear analog-to-digital converter, which performs simultaneous linearization and digitalization of the pseudo-linear signal. As a result, the maximal value of the absolute measurement error equals to 3.77168·10-5 [rad] (0.00216°) over the full measurement range of 2π [rad].

  12. Recent developments of genetically encoded optical sensors for cell biology.

    Science.gov (United States)

    Bolbat, Andrey; Schultz, Carsten

    2017-01-01

    Optical sensors are powerful tools for live cell research as they permit to follow the location, concentration changes or activities of key cellular players such as lipids, ions and enzymes. Most of the current sensor probes are based on fluorescence which provides great spatial and temporal precision provided that high-end microscopy is used and that the timescale of the event of interest fits the response time of the sensor. Many of the sensors developed in the past 20 years are genetically encoded. There is a diversity of designs leading to simple or sometimes complicated applications for the use in live cells. Genetically encoded sensors began to emerge after the discovery of fluorescent proteins, engineering of their improved optical properties and the manipulation of their structure through application of circular permutation. In this review, we will describe a variety of genetically encoded biosensor concepts, including those for intensiometric and ratiometric sensors based on single fluorescent proteins, Forster resonance energy transfer-based sensors, sensors utilising bioluminescence, sensors using self-labelling SNAP- and CLIP-tags, and finally tetracysteine-based sensors. We focus on the newer developments and discuss the current approaches and techniques for design and application. This will demonstrate the power of using optical sensors in cell biology and will help opening the field to more systematic applications in the future. © 2016 Société Française des Microscopies and Société de Biologie Cellulaire de France. Published by John Wiley & Sons Ltd.

  13. Multi-DOF Incremental Optical Encoder with Laser Wavelength Compensation

    Directory of Open Access Journals (Sweden)

    Cha'o-Kuang Chen

    2013-09-01

    Full Text Available This study used a reflective diffraction grating as the medium to develop a multi-DOF incremental optical encoder for motion stage. The optical encoder can measure three angular displacements, roll, yaw and pitch of the motion stage simultaneously, as well as the horizontal straightness and linear displacement, summed to five DOF errors of motion stage by only using the positive and negative first-order diffracted light. The grating diffraction theory, Doppler effect, and optical interference technique were used. Two quadrant photodetectors were used to measure the changes in three-dimensional space of diffraction direction of diffracted light, in order to construct a multi-DOF incremental optical encoder. Considering the working stability of a laser diode and preventing the influence of the zeroth-order diffracted light returning to the laser diode, an additional optical isolation system was designed and a wavelength variation monitoring module was created. The compensation for the light source wavelength variation could be 0.001 nm. The multi-DOF verification results showed that the roll error is ±0.7/60 arcsec, the standard deviation is 0.025 arcsec; the yaw error is ±0.7/30 arcsec, the standard deviation is 0.05 arcsec; the pitch error is ±0.8/90 arcsec, the standard deviation is 0.18 arcsec, the horizontal straightness error is ±0.5/250 μm, the standard deviation is 0.05 μm and the linear displacement error is ±1/20000 μm, the standard deviation is 12 nm.

  14. Measuring human ventilation for apnoea detection using an optical encoder.

    Science.gov (United States)

    Weinberg, G M; Webster, J G

    1998-08-01

    We have designed, built and tested a proof-of-concept system based on optical encoder technology for measuring adult or infant ventilation. It uses change in chest circumference to provide an indirect measure of ventilation. The Hewlett-Packard HEDS-9720 optical encoder senses displacement of its matching codestrip. It yields a resolution of 0.17 mm and is accurate to 0.008 mm over a 10 mm test distance. The encoder is mounted on a nylon web belt wrapped around the torso and responds to changes in circumference. Motion of the code strip during respiration is converted to direction of movement (inhalation or exhalation) as well as magnitude of circumference change. Use of two sensor bands, one on the chest and one on the abdomen, may allow detection of obstructive apnoea in which there is no air flow out of or into the subject despite respiratory movement. Applications of this technology include infant apnoea monitoring as well as long-term adult monitoring.

  15. Optical Shaft-Angle Encoder For Helicopter Rotor

    Science.gov (United States)

    Golub, Robert A.; Fitzpatrick, Fred; Dennis, Dale V.; Taylor, Bryant D.

    1993-01-01

    Angular position of helicopter rotor blade determined precisely. Accomplished by use of optical shaft-angle encoder called "256 Ring" on rotor swashplate. Each 360 degree rotation of helicopter main rotor broken down into 256 reflective segments. As rotor rotates, beam of light reflected in turn from each segment into optoelectronic system. One of 256 segments reflects larger pulse than others do. Position of rotor determined by counting number of pulses after this reference pulse. While swashplate mounting requirements unique to each type of helicopter, concept applicable to all types of rotorcraft.

  16. Research on application of photoelectric rotary encoder in space optical remote sensor

    Science.gov (United States)

    Zheng, Jun; Qi, Shao-fan; Wang, Yuan-yuan; Zhang, Zhan-dong

    2016-11-01

    For space optical remote sensor, especially wide swath detecting sensor, the focusing control system for the focal plane should be well designed to obtain the best image quality. The crucial part of this system is the measuring instrument. For previous implements, the potentiometer, which is essentially a voltage divider, is usually introduced to conduct the position in feedback closed-loop control process system. However, the performances of both electro-mechanical and digital potentiometers is limited in accuracy, temperature coefficients, and scale range. To have a better performance of focal plane moving detection, this article presents a new measuring implement with photoelectric rotary encoder, which consists of the photoelectric conversion system and the signal process system. In this novel focusing control system, the photoelectric conversion system is fixed on main axis, which can transform the angle information into a certain analog signal. Through the signal process system, after analog-to-digital converting and data format processing of the certain analog signal, the focusing control system can receive the digital precision angle position which can be used to deduct the current moving position of the focal plane. For utilization of space optical remote sensor in aerospace areas, the reliability design of photoelectric rotary encoder system should be considered with highest priority. As mentioned above, this photoelectric digital precision angle measurement device is well designed for this real-time control and dynamic measurement system, because its characters of high resolution, high accuracy, long endurance, and easy to maintain.

  17. Frequency encoded optical assessment of human retinal physiology

    Science.gov (United States)

    Leitgeb, Rainer A.; Michaely, Roland; Bachmann, Adrian; Lassner, Theo; Blatter, Cedric

    2008-02-01

    We demonstrate in-vivo functional imaging of the human retina with Fourier domain optical coherence tomography employing frequency encoding of an excitation pattern. The principle is based on projecting a modulated rectangular pattern across the foveal region and acquiring a time series of B-Scans at the same vertical position across the pattern. The idea is to modulate the excitation with a frequency that is distinct from the heartbeat and irregular motion artifacts. Fourier analysis of the time series at each transverse position in the B-scan series allows assessing the retinal response as change in the FDOCT reflectivity signal exactly at the pattern modulation frequency. We observe a change in retinal reflectivity within the region of the outer segment photoreceptor layer exactly at the pattern modulation frequency.

  18. The All-fiber MZI Structure for Optical DPSK Demodulation and Optical PSBT Encoding

    Directory of Open Access Journals (Sweden)

    Guillaume Ducournau

    2006-08-01

    Full Text Available Since the beginning of optical telecommunications, the most simple modulation format has been employed in optical links. This format is called OOK (On Off Keying. With the increases in bit rates, number of optical channels in Dense Wavelength Division Multiplexing (DWDM configuration, and the augmentation of power in each channel, new modulation formats have been studied in the last years. Today, in order to increase the quality of optical links, tendency is to modify the modulation scheme used to encode information in light signals. Particularly, the Differential Phase Shift Keying (DPSK format presents an increased tolerance to non-linear effects in optical fibers, justifying the interest for using this format in optical communications links. In the past two years, some studies investigated the possibilities to transmit 40 Gbps data rates on the deployed 10 Gbps links. An interesting solution consists in using the Phase Shaped Binary Transmission (PSBT modulation format. With this technique, the system upgrade costs from 10 Gbps to 40 Gbps are reduced, justifying the use of PSBT. In this paper, we present two applications of Mach-Zehnder Inteferometers (MZIs, used in optical communication links. We first review the principles of the Differential Phase Shift Keying (DPSK, a phase modulation scheme, and its interest in optical communications. After that, we also focus on a recently introduced modulation format: the all-optical Phase Shaped Binary Transmission (PSBT.

  19. Studies in electromagnetic compatibility of optical and digital current and voltage transformers

    Science.gov (United States)

    Lebedev, V. D.; Yablokov, A. A.

    2017-02-01

    The use of microprocessor devices for relay protection and automation, devices for measuring and determining electric power quality permits the introduction and development of digital circuits leading from primary current and voltage transformers. The use of optical channels for digital circuits addresses the problem of offsetting electromagnetic interference and voltage shift. Creating optical and digital current and voltage transformers with digitization of signals already at high measuring transformer voltage is the best solution for the above problem of mechanical engineering in the field of electromagnetic compatibility of high voltage measuring transformers. However, a difficulty arises in ensuring electromagnetic compatibility of sensors and microelectronic equipment adjoining live parts. The present study is devoted to examining the impact of electromagnetic fields on sensors and solving the problems of electromagnetic compatibility of optical and digital current and voltage transformers.

  20. Optical label encoding using electroabsorption modulators and investigation of chirp properties

    DEFF Research Database (Denmark)

    Xu, Lin; Chi, Nan; Oxenløwe, Leif Katsuo

    2003-01-01

    A novel scheme of optical label encoding by wavelength conversion based on electroabsorption modulators (EAMs) is reported. Based on the experimental observations, the chirp properties of the wavelength-converted signal are discussed and a wide dynamic range of the chirp α-parameter is found...... allowed. Compared with cross-gain modulation (XGM) in a semiconductor optical amplifier (SOA), the EAM has several advantages, which make it attractive for optical label encoding or other applications as a wavelength converter....

  1. Design, construction, and test of a passive optical prototype high voltage instrument transformer

    DEFF Research Database (Denmark)

    Christensen, Lars Hofmann

    1995-01-01

    This paper describes an optical voltage transformer (OVT) for a 132-130 kV system based on the Pockels effect in a Bi4Ge3O12 crystal. Different from the majority of OVTs reported, this construction does not use any capacitive voltage division. To accomplish this, it was necessary to redesign...

  2. 110-KV optical fiber voltage transformer using a porcelain capacitor divider

    Science.gov (United States)

    Ye, Miaoyuan; Ou, Chaolong; Cui, Ying; Zhou, Jianying; Li, Kaicheng; Chen, Zhiping; Xu, Yan; Luo, Sunan

    1998-08-01

    In this paper, a new type of optical fiber voltage transformer is introduced, which utilizes new porcelain capacitor divider. The optical; fiber voltage sensor is based on the BGO crystal Pockels effect modulated horizontally, sealed in a glass box with low expansion rate. Both the divider and the sensor are sealed in the compound silicon rubber insulator filled with SF6 gas. It has many advantages such as small volume, light weight, low price and high precision.

  3. Photoacoustic imaging of voltage responses beyond the optical diffusion limit

    National Research Council Canada - National Science Library

    Bin Rao; Ruiying Zhang; Lei Li; Jin-Yu Shao; Lihong V Wang

    2017-01-01

    .... Although photoacoustic tomography breaks this limit by exciting the targets with diffused photons and detecting the resulting acoustic responses, it has not been demonstrated as a modality for imaging voltage responses...

  4. DC-balanced line encoding for optical labeling scheme using orthogonal modulation

    DEFF Research Database (Denmark)

    Zhang, Jianfeng; Holm-Nielsen, Pablo Villanueva; Chi, Nan

    2004-01-01

    It is shown both theoretically and experimentally that 8B/10B encoding is an efficient technique to mitigate the inherent modulation crosstalk in optical labeling scheme using orthogonal modulation....

  5. Acousto-Optical Method of Encoding and Visualization of Underwater Space

    Science.gov (United States)

    2014-01-27

    08-2015 Publication Acousto- Optical Method of Encoding and Visualization of Underwater Space Promode R. Bandyopadhyay Naval Undersea Warfare Center...like transducers is recorded as holograms and transmitted. The hologram is decoded and a hologram of the underwater space is created. A small...STATEMENT Approved for Public Release Distribution is unlimited Attorney Docket No. 101454 1 of 34 ACOUSTO- OPTICAL METHOD OF ENCODING AND

  6. A novel optical rotary encoder with eccentricity self-detection ability

    Science.gov (United States)

    Li, Xuan; Ye, Guoyong; Liu, Hongzhong; Ban, Yaowen; Shi, Yongsheng; Yin, Lei; Lu, Bingheng

    2017-11-01

    Eccentricity error is the main error source of optical rotary encoders. Real-time detection and compensation of the eccentricity error is an effective way of improving the accuracy of rotary optical encoders. In this paper, a novel rotary optical encoder is presented to realize eccentricity self-detection. The proposed encoder adopts a spider-web-patterned scale grating as a measuring standard which is scanned by a dual-head scanning unit. Two scanning heads of the dual-head scanning unit, which are arranged orthogonally, have the function of scanning the periodic pattern of the scale grating along the angular and radial directions, respectively. By this means, synchronous measurement of angular and radial displacements of the scale grating is realized. This paper gives the details of the operating principle of the rotary optical encoder, developing and testing work of a prototype. The eccentricity self-detection result agrees well with the result measured by an optical microscope. The experimental result preliminarily proves the feasibility and effectiveness of the proposed optical encoder.

  7. Digital ultrasonically encoded (DUE) optical focusing into random media

    CERN Document Server

    Tay, Jian Wei; Suzuki, Yuta; Wang, Lihong V

    2013-01-01

    Focusing light into opaque random or scattering media such as biological tissue is a much sought-after goal for biomedical applications such as photodynamic therapy, optical manipulation, and photostimulation. However, focusing with conventional lenses is restricted to one transport mean free path in scattering media, limiting both optical penetration depth and resolution. Focusing deeper is possible by using optical phase conjugation or wavefront shaping to compensate for the scattering. For practical applications, wavefront shaping offers the advantage of a robust optical system that is less sensitive to optical misalignment. Here, the phase of the incident light is spatially tailored using a phase-shifting array to pre-compensate for scattering. The challenge, then, is to determine the phase pattern which allows light to be optimally delivered to the target region. Optimization algorithms are typically employed for this purpose, with visible particles used as targets to generate feedback. However, using th...

  8. Fiber optic angular orientation sensor digital serial encoding

    OpenAIRE

    Garrett, Steven L.; Brininstool, Michael R.; Newmaster, Jeffrey T.; Hofler, Thomas

    1991-01-01

    Patent Number: 5,042,157 A sensor provides remote angular orientation sensing. A rotational signal transmitted to a rotatable input shaft mounted in an encoder body causes the shaft to rotate. Light signals are transmitted through a digital code wheel mounted to the shaft. As the code wheel and shaft rotate, the light signals passing through the code wheel are superimposed with light pulses corresponding to incremental and directional changes of anuglar position of the code wheel with...

  9. Possibilities for Advanced Encoding Techniques at Signal Transmission in the Optical Transmission Medium

    Directory of Open Access Journals (Sweden)

    Filip Čertík

    2016-01-01

    Full Text Available This paper presents a possible simulation of negative effects in the optical transmission medium and an analysis for the utilization of different signal processing techniques at the optical signal transmission. An attention is focused on the high data rate signal transmission in the optical fiber influenced by linear and nonlinear environmental effects presented by the prepared simulation model. The analysis includes possible utilization of OOK, BPSK, DBPSK, BFSK, QPSK, DQPSK, 8PSK, and 16QAM modulation techniques together with RS, BCH, and LDPC encoding techniques for the signal transmission in the optical fiber. Moreover, the prepared simulation model is compared with real optical transmission systems. In the final part, a comparison of the selected modulation techniques with different encoding techniques and their implementation in real transmission systems is shown.

  10. Enumerative Encoding of TMTR Codes for Optical Recording Channel

    Directory of Open Access Journals (Sweden)

    Tsai Hui-Feng

    2010-01-01

    Full Text Available We propose a new time-varying maximum transition run (TMTR code for DVD recording systems, which has a rate higher than the EFMPlus code and a lower power spectral density (PSD at low frequencies. An enumeration method for constructing the new TMTR code is presented. Computer simulations indicate that the proposed TMTR code outperforms the EFMPlus code in error performance when applied to partial response optical recording channels.

  11. Optical folding-flash analog-to-digital converter with analog encoding.

    Science.gov (United States)

    Jalali, B; Xie, Y M

    1995-09-15

    We describe an optically assisted folding-flash analog-to-digital converter. The periodic transfer function of the Mach-Zehnder interferometer is used to perform analog folding on the electronic signal to be quantized. A novel analog encoding scheme for efficient generation of gray code digital data is proposed. The new encoding scheme eliminates the requirement for interferometers with ultralow V(pi), which, so far, has hindered the development of such systems. The encoding concept is experimentally demonstrated through the use of LiNbO(3) modulators.

  12. Speckle reduction in optical coherence tomography by "path length encoded" angular compounding.

    Science.gov (United States)

    Iftimia, N; Bouma, B E; Tearney, G J

    2003-04-01

    Speckle, the dominant factor reducing image quality in optical coherence tomography (OCT), limits the ability to identify cellular structures that are essential for diagnosis of a variety of diseases. We describe a new high-speed method for implementing angular compounding by path length encoding (ACPE) for reducing speckle in OCT images. By averaging images obtained at different incident angles, with each image encoded by path length, ACPE maintains high-speed image acquisition and requires minimal modifications to OCT probe optics. ACPE images obtained from tissue phantoms and human skin in vivo demonstrate a qualitative improvement over traditional OCT and an increased SNR that correlates well with theory.

  13. Spectral reading of optical resonance-encoded cells in microfluidics.

    Science.gov (United States)

    Humar, Matjaž; Upadhya, Avinash; Yun, Seok Hyun

    2017-08-08

    The ability to label individual cells is useful for single-cell-level studies of complex cellular interactions and heterogeneity. Optically readable cell labeling is attractive as it can be investigated non-invasively and repeatedly at high speeds. Here, we demonstrate the feasibility of large-scale cell barcoding and identification using fluorescent polystyrene microbeads loaded into cells. Intracellular beads with different diameters in a range of 5 to 12 μm generate spectrally distinguished features or barcodes. A microfluidic chip was used to measure fluorescence resonance peaks emitted from individual cells. An algorithm comparing the peak wavelengths to a reference barcode library allowed barcode identification with high accuracy. This work provides a guideline to increase the number of unique identifiers and reduce various false-positive and false-negative errors.

  14. Electronic Measurement Systems and Procedures for Optical Encoder and Force Sensor Studying

    OpenAIRE

    Dorina Purcaru; Elena Niculescu; Cornelia Gordan

    2009-01-01

    The experimental measurement systems arevery useful in engineering education because the studentscan use and verify their previous knowledge aboutsensors and transducers, signal conditioning and dataprocessing. This paper presents two electronicmeasurement systems which enable the computerizedstudy of the optical encoder and force sensor, respectively.The first sensor studying procedure performs theunderstanding and checking of the rotary incrementalencoder working modes and methods for resol...

  15. Current-voltage characteristics of light-emitting diodes under optical and electrical excitation

    Energy Technology Data Exchange (ETDEWEB)

    Wen Jing; Wen Yumei; Li Ping; Li Lian, E-mail: wenjing@cqu.edu.cn [Key Laboratory for Opto-Electronic Technologies and Systems of Ministry of Education, College of Opto-Electronic Engineering, Chongqing University, Chongqing 400044 (China)

    2011-08-15

    The factors influencing the current-voltage (I-V) characteristics of light-emitting diodes (LEDs) are investigated to reveal the connection of I-V characteristics under optical excitation and those under electrical excitation. By inspecting the I-V curves under optical and electrical excitation at identical injection current, it has been found that the I-V curves exhibit apparent differences in voltage values. Furthermore, the differences are found to originate from the junction temperatures in diverse excitation ways. Experimental results indicate that if the thermal effect of illuminating spot is depressed to an ignorable extent by using pulsed light, the junction temperature will hardly deflect from that under optical excitation, and then the I-V characteristics under two diverse excitation ways will be the same.

  16. Current-voltage characteristics of light-emitting diodes under optical and electrical excitation

    Science.gov (United States)

    Jing, Wen; Yumei, Wen; Ping, Li; Lian, Li

    2011-08-01

    The factors influencing the current—voltage (I—V) characteristics of light-emitting diodes (LEDs) are investigated to reveal the connection of I—V characteristics under optical excitation and those under electrical excitation. By inspecting the I—V curves under optical and electrical excitation at identical injection current, it has been found that the I—V curves exhibit apparent differences in voltage values. Furthermore, the differences are found to originate from the junction temperatures in diverse excitation ways. Experimental results indicate that if the thermal effect of illuminating spot is depressed to an ignorable extent by using pulsed light, the junction temperature will hardly deflect from that under optical excitation, and then the I—V characteristics under two diverse excitation ways will be the same.

  17. Multiple-wavelength double random phase encoding with CCD-plane sparse-phase multiplexing for optical information verification.

    Science.gov (United States)

    Chen, Wen

    2015-12-20

    A novel method is proposed by using multiple-wavelength double random phase encoding (MW-DRPE) with CCD-plane sparse-phase multiplexing for optical information verification. Two different strategies are applied to conduct sparse-phase multiplexing in the CCD plane. The results demonstrate that large capacity can be achieved for optical multiple-image verification. The proposed optical verification strategy is implemented based on optical encoding, and the keys generated by optical encryption can further guarantee the safety of the designed optical multiple-image verification system. The proposed method provides a novel alternative for DRPE-based optical information verification.

  18. Experimental polarization encoded quantum key distribution over optical fibres with real-time continuous birefringence compensation

    Energy Technology Data Exchange (ETDEWEB)

    Xavier, G B; Vilela de Faria, G; Temporao, G P; Von der Weid, J P [Centre for Telecommunication Studies, Pontifical Catholic University of Rio de Janeiro-R Marques de Sao Vicente 225 Gavea, Rio de Janeiro (Brazil); Walenta, N; Gisin, N; Zbinden, H [GAP-Optique, University of Geneva, rue de l' Ecole-de-Medecine 20, CH-1211 Geneva 4 (Switzerland)], E-mail: guix@opto.cetuc.puc-rio.br

    2009-04-15

    In this paper we demonstrate an active polarization drift compensation scheme for optical fibres employed in a quantum key distribution experiment with polarization encoded qubits. The quantum signals are wavelength multiplexed in one fibre along with two classical optical side channels that provide the control information for the polarization compensation scheme. This set-up allows us to continuously track any polarization change without the need to interrupt the key exchange. The results obtained show that fast polarization rotations of the order of 40{pi} rad s{sup -1} are effectively compensated for. We demonstrate that our set-up allows continuous quantum key distribution even in a fibre stressed by random polarization fluctuations. Our results pave the way for Bell-state measurements using only linear optics with parties separated by long-distance optical fibres.

  19. Ultra-high, resolution, modular optical angle encoder for space-based opto-mechanical applications

    Science.gov (United States)

    Luther, Holger; Beard, Paul; Mitchell, Donald; Thorburn, William

    1995-01-01

    A 27-bit optical encoder using a novel patent pending technology has been developed by the MicroE Development Center of BEI Sensors & Systems Company and tested by the Sensor Systems Group (SSG) Inc., in a positioning and stabilization mirror assembly (PSMA) designed and constructed under a grant from the Marshall Space Flight Center. Test results verified performance within the specifications of the PSMA.

  20. A spectral phase encoded time spreading optical code division multiple access testbed

    Science.gov (United States)

    Cong, Wei

    Spectral phase-encode time-spreading (SPECTS) is a promising technique for optical code-division multiple-access (O-CDMA) networks. In SPECTS O-CDMA, users are multiplexed and distinguished with unique phase codes impressed on the spectrum of ultra-short optical signal pulses. The encoding and decoding processes are implemented with grating/lens zero-dispersion pulse-shapers using spatial light phase modulators (SLPMs) in the Fourier plane. The SLPMs add the encoding or decoding O-CDMA phase codes on the spectrum which is spatially spread and then recombined by the grating(s) and lens(es). In this dissertation, we demonstrate a SPECTS O-CDMA network testbed with large throughputs and high performances. Two types of fiber-pigtailed bulk-optic pulseshapers, 1-D transparent-mode and 2-D reflective-mode, are constructed to be used as SPECTS O-CDMA encoders and decoders in the testbed. In order to support a large number of users, the testbed includes up to eight SPECTS O-CDMA encoding channels and one decoding channel. With the combination of time-slotting and polarization-multiplexing operations, the maximum throughput achieved on the testbed is 32 users (8 O-CDMA channel x 2 time slots x 2 polarizations) at 10 Gb/s/user. Two nonlinear detecting techniques (thresholding and gating) for coherent SPECTS O-CDMA are discussed in the dissertation. A nonlinear thresholder and a nonlinear optical loop mirror (NOLM) time gate are built in the testbed; each uses a 500-m highly nonlinear fiber(HNLF). An "O-CDMA receiver" including the NOLM and the thresholder followed by an optical-electrical (O-E) converter can distinguish the intended user by demultiplexing the time-slotted signal and then suppressing the multi-user interference (MUI). In the bit-error-rate (BER) statistics experiments, the "O-CDMA receiver" can detect the intended user's signal with error-free or low BER performance in various testbed structures. Network-layer application experiments including video

  1. Fiber optic voltage sensor for 420 kV electric power systems

    Science.gov (United States)

    Bohnert, Klaus M.; Kostovic, Jadran; Pequignot, P.

    2000-11-01

    We present an optical fiber voltage sensor for 420 kV electric power lines. The sensor exploits the converse piezoelectric effect of quartz and measures the voltage by a line integration of the electric field. The alternating voltage is partitioned to a series of four cylinder-shaped quartz crystals, which are embedded in polyurethane resin within a 3.2-m long insulator tube of fiber reinforced epoxy. The alternating piezoelectric deformations of the crystals are sensed by a common elliptical-core dual-mode fiber, which is wound onto the circumferential crystal surfaces. The fiber is interrogated using low coherence interferometry. We determine the dielectric design of the sensor from a numerical analysis of the electric field distribution within and in the vicinity of the sensor. We experimentally verify the dielectric reliability under ac overvoltages up to 520 kV root mean square and lightning and switching impulse voltages up to 1425 and 1050 kV, respectively. Further, we investigate the sensor performance including accuracy, dynamic range, bandwidth, and temperature dependence.

  2. Optical information authentication via compressed sensing and double random phase encoding

    Science.gov (United States)

    Chen, Junxin; Bao, Nan; Zhu, Zhi-liang

    2017-10-01

    This paper presents a novel information authentication scheme via compressed sensing and double random phase encoding. Two alternative architectures have been investigated, in which significantly compressed data with micro percentage is sufficient for authentication. At the decoder end, a noise-like image with no leakage of the plaintext is recovered and subsequently authenticated using a nonlinear optical correlation approach. The authentication effectiveness, noise resistance and security performance of the proposed scheme have been experimentally validated. This work was supported by the Fundamental Research Funds for the Central Universities (N162410002-4, N151904002), the National Natural Science Foundation of China (No. 61374178).

  3. Fractional Fourier transform-based optical encryption with treble random phase-encoding

    Science.gov (United States)

    Xin, Yi; Tao, Ran; Wang, Yue

    2008-03-01

    We propose a new architecture of optical encryption technique using the fractional Fourier transform with three statistically independent random phase masks. Compared with the existing double-phase encoding method in the fractional Fourier-domain, the proposed extra phase mask in the last fractional Fourier domain makes the architecture symmetrical, and additive processing to the encrypted image can be turned into complex stationary white noise after decryption, and enlarge the key space without any degradation of its robustness to blind decryption. This property can be utilized to improve the quality of the recover image. Simulation results have verified the validity.

  4. Optical image encoding based on digital holographic recording on polarization state of vector wave.

    Science.gov (United States)

    Lin, Chao; Shen, Xueju; Xu, Qinzu

    2013-10-01

    We propose and analyze a compact optical image encoder based on the principle of digital holographic recording on the polarization state of a vector wave. The optical architecture is a Mach-Zehnder interferometer with in-line digital holographic recording mechanism. The original image is represented by distinct polarization states of elliptically polarized light. This state of polarization distribution is scrambled and then recorded by a two-step digital polarization holography method with random phase distributed reference wave. Introduction of a rotation key in the object arm and phase keys in the reference arm can achieve the randomization of plaintext. Statistical property of cyphertext is analyzed from confusion and diffusion point of view. Fault tolerance and key sensitivity of the proposed approach are also investigated. A chosen plaintext attack on the proposed algorithm exhibits its high security level. Simulation results that support the theoretical analysis are presented.

  5. Optical position sensor based on a digital wavelength-encoding grating ruler

    Science.gov (United States)

    Wang, Yu; Chen, Huoyao; Liu, Zhengkun; Hong, Yilin

    2016-10-01

    A wavelength-encoding optical position sensor was designed in this study. The critical component of the sensor is its innovative digital encoding grating ruler (DEGR), which is a substrate on which several blazed grating units with different line densities are arranged parallel to one another following a certain order. Two types of multi-DEGR were designed. We obtained over 100,000 codes that significantly assisted in designing long-range and high-resolution position sensors by optimizing the coding algorithm. The wavelength signals generated by the multi-DEGR were demodulated using concave grating and several photosensitive elements. A 100-mm multi-DEGR with 1000 codes was successfully fabricated using the combined methods of direct laser writing and holographic technology. We described the principle of the sensor in detail and established the entire sensor system. A bench test was conducted to test the signal response of the sensor. Bench test results exhibited 100% accuracy of the signal response of the optical sensor and an excellent temperature performance within -55°C and 75°C.

  6. Boosting of synaptic potentials and spine Ca transients by the peptide toxin SNX-482 requires alpha-1E-encoded voltage-gated Ca channels.

    Directory of Open Access Journals (Sweden)

    Andrew J Giessel

    Full Text Available The majority of glutamatergic synapses formed onto principal neurons of the mammalian central nervous system are associated with dendritic spines. Spines are tiny protuberances that house the proteins that mediate the response of the postsynaptic cell to the presynaptic release of glutamate. Postsynaptic signals are regulated by an ion channel signaling cascade that is active in individual dendritic spines and involves voltage-gated calcium (Ca channels, small conductance (SK-type Ca-activated potassium channels, and NMDA-type glutamate receptors. Pharmacological studies using the toxin SNX-482 indicated that the voltage-gated Ca channels that signal within spines to open SK channels belong to the class Ca(V2.3, which is encoded by the Alpha-1E pore-forming subunit. In order to specifically test this conclusion, we examined the effects of SNX-482 on synaptic signals in acute hippocampal slices from knock-out mice lacking the Alpha-1E gene. We find that in these mice, application of SNX-482 has no effect on glutamate-uncaging evoked synaptic potentials and Ca influx, indicating that that SNX-482 indeed acts via the Alpha-1E-encoded Ca(V2.3 channel.

  7. Reconfigurable dual-channel all-optical logic gate in a silicon waveguide using polarization encoding.

    Science.gov (United States)

    Gao, Shiming; Wang, Xiaoyan; Xie, Yanqiao; Hu, Peiran; Yan, Qiang

    2015-04-01

    A reconfigurable dual-channel all-optical logic gate is proposed and experimentally demonstrated using four-wave mixing in a silicon waveguide for polarization encoding signals. Six logic functions, XNOR, AND, NOR, XOR, AB¯, and A¯B are implemented at two different wavelength channels by adjusting the polarization states of two 10 Gb/s non-return-to-zero polarization-shift keying (NRZ-PolSK) signals modulated by 10-bit on-off keying (OOK) sequences. The eye diagrams of the logic signals are clearly observed, and the logic functions are well demonstrated as the two incident NRZ-PolSK signals are both modulated by the OOK sequences, which originate from 2(31)-1 pseudo-random binary sequences.

  8. Fabrication of high edge-definition steel-tape gratings for optical encoders

    Science.gov (United States)

    Ye, Guoyong; Liu, Hongzhong; Yan, Jiawei; Ban, Yaowen; Fan, Shanjin; Shi, Yongsheng; Yin, Lei

    2017-10-01

    High edge definition of a scale grating is the basic prerequisite for high measurement accuracy of optical encoders. This paper presents a novel fabrication method of steel tape gratings using graphene oxide nanoparticles as anti-reflective grating strips. Roll-to-roll nanoimprint lithography is adopted to manufacture the steel tape with hydrophobic and hydrophilic pattern arrays. Self-assembly technology is employed to obtain anti-reflective grating strips by depositing the graphene oxide nanoparticles on hydrophobic regions. A thin SiO2 coating is deposited on the grating to protect the grating strips. Experimental results confirm that the proposed fabrication process enables a higher edge definition in making steel-tape gratings, and the new steel tape gratings offer better performance than conventional gratings.

  9. Fabrication of high edge-definition steel-tape gratings for optical encoders.

    Science.gov (United States)

    Ye, Guoyong; Liu, Hongzhong; Yan, Jiawei; Ban, Yaowen; Fan, Shanjin; Shi, Yongsheng; Yin, Lei

    2017-10-01

    High edge definition of a scale grating is the basic prerequisite for high measurement accuracy of optical encoders. This paper presents a novel fabrication method of steel tape gratings using graphene oxide nanoparticles as anti-reflective grating strips. Roll-to-roll nanoimprint lithography is adopted to manufacture the steel tape with hydrophobic and hydrophilic pattern arrays. Self-assembly technology is employed to obtain anti-reflective grating strips by depositing the graphene oxide nanoparticles on hydrophobic regions. A thin SiO 2 coating is deposited on the grating to protect the grating strips. Experimental results confirm that the proposed fabrication process enables a higher edge definition in making steel-tape gratings, and the new steel tape gratings offer better performance than conventional gratings.

  10. Electronic Measurement Systems and Procedures for Optical Encoder and Force Sensor Studying

    Directory of Open Access Journals (Sweden)

    Dorina Purcaru

    2009-10-01

    Full Text Available The experimental measurement systems arevery useful in engineering education because the studentscan use and verify their previous knowledge aboutsensors and transducers, signal conditioning and dataprocessing. This paper presents two electronicmeasurement systems which enable the computerizedstudy of the optical encoder and force sensor, respectively.The first sensor studying procedure performs theunderstanding and checking of the rotary incrementalencoder working modes and methods for resolutionimprovement, displacement and velocity measurement,and motion sense discrimination. The second sensorstudying procedure supposes the assignation of themeasurement points, plotting the transfer characteristicand computing some parameters (zero error, differentialsensitivity, relative sensitivity of the strain gaugetransducer; the measured mass of the tested object canalso be displayed. Each electronic measurement systemcontains signal conditioning circuits, data acquisitionboard (organized around a microcontroller and an IBMPCcompatible computer; the data acquisition board isserial connected to computer. A friendly user interfaceenables each computerized sensor study. The paper alsoincludes many experimental results.

  11. An investigation into the development of an alternative optical shaft encoder

    OpenAIRE

    2012-01-01

    M.Ing. Shaft encoders, are devices generally used in speed and position control applications for sensing position of rotational and linearly moving objects. Most conventional shaft encoders operate on the principle of reading encoded information off a disk, which is fitted to the shaft or using resolver units. Problems are often experienced in fitting high-resolution encoder disks or resolvers to small motors or moving objects. The resolution of an encoder system, using an encoded disk, is...

  12. Optical Encoding Technology for Viral Screening Panels Final Report CRADA No TC02132.0

    Energy Technology Data Exchange (ETDEWEB)

    Lenhoff, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Haushalter, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-08-15

    This was a collaborative effort between Lawrence Livermore National Security, LLC, Lawrence Livermore National Laboratory (LLNL) and Parallel Synthesis Technologies, Inc. (PSTI), to develop Optical Encoding Technology for Viral Screening Panels. The goal for this effort was to prepare a portable bead reader system that would enable the development of viral and bacterial screening panels which could be used for the detection of any desired set of bacteria or viruses in any location. The main objective was to determine if the combination of a bead-based, PCR suspension array technology, formulated from Parallume encoded beads and PSTI’s multiplex assay reader system (MARS), could provide advantages in terms of the number of simultaneously measured samples, portability, ruggedness, ease of use, accuracy, precision or cost as compared to the Luminexbased system developed at LLNL. The project underwent several no cost extensions however the overall goal of demonstrating the utility of this new system was achieved. As a result of the project a significant change to the type of bead PSTI used for the suspension system was implemented allowing better performance than the commercial Luminex system.

  13. Towards polarisation-encoded quantum key distribution in optical fibre networks

    Directory of Open Access Journals (Sweden)

    Sharmini Pillay

    2015-07-01

    Full Text Available Quantum key distribution a process that encodes digital information often utilises fibre optic technologies for commercial applications. Fibre provides the benefit of a dark channel as well as the convenience of independence of a line-of-sight connection between the sender and receiver. In order to implement quantum key distribution protocols utilising polarisation encoding, the birefringence effects of fibre must be compensated for. Birefringence is caused by manufacturing impurities in the fibre or a change in environmental conditions and results in a rotation of the state of polarisation of light as it is propagated through the fibre. With dynamic environmental conditions, the birefringence effects should be monitored with a test signal at regular time intervals so that the polarisation of each photon can be appropriately compensated to its original state. Orthogonal states are compensated simultaneously, but most protocols, such as BB84 and B92, require non-orthogonal basis sets. Instead of using a compensator for each basis, the presented scheme fixes the polarisation controller onto the plane on the Poincar that passes through both bases, compensating both non-orthogonal bases simultaneously.

  14. Method of all-optical frequency encoded decimal to binary and binary coded decimal, binary to gray, and gray to binary data conversion using semiconductor optical amplifiers

    Science.gov (United States)

    Garai, Sisir Kumar

    2011-07-01

    Conversion of optical data from decimal to binary format is very important in optical computing and optical signal processing. There are many binary code systems to represent decimal numbers, the most common being the binary coded decimal (BCD) and gray code system. There are a wide choice of BCD codes, one of which is a natural BCD having a weighted code of 8421, by means of which it is possible to represent a decimal number from 0 to 9 with a combination of 4bit binary digits. The reflected binary code, also known as the Gray code, is a binary numeral system where two successive values differ in only 1bit. The Gray code is very important in digital optical communication as it is used to prevent spurious output from optical switches as well as to facilitate error correction in digital communications in an optical domain. Here in this communication, the author proposes an all-optical frequency encoded method of ``:decimal to binary, BCD,'' ``binary to gray,'' and ``gray to binary'' data conversion using the high-speed switching actions of semiconductor optical amplifiers. To convert decimal numbers to a binary form, a frequency encoding technique is adopted to represent two binary bits, 0 and 1. The frequency encoding technique offers advantages over conventional encoding techniques in terms of less probability of bit errors and greater reliability. Here the author has exploited the polarization switch made of a semiconductor optical amplifier (SOA) and a property of nonlinear rotation of the state of polarization of the probe beam in SOA for frequency conversion to develop the method of frequency encoded data conversion.

  15. In Situ Optical Mapping of Voltage and Calcium in the Heart

    Science.gov (United States)

    Ewart, Paul; Ashley, Euan A.; Loew, Leslie M.; Kohl, Peter; Bollensdorff, Christian; Woods, Christopher E.

    2012-01-01

    Electroanatomic mapping the interrelation of intracardiac electrical activation with anatomic locations has become an important tool for clinical assessment of complex arrhythmias. Optical mapping of cardiac electrophysiology combines high spatiotemporal resolution of anatomy and physiological function with fast and simultaneous data acquisition. If applied to the clinical setting, this could improve both diagnostic potential and therapeutic efficacy of clinical arrhythmia interventions. The aim of this study was to explore this utility in vivo using a rat model. To this aim, we present a single-camera imaging and multiple light-emitting-diode illumination system that reduces economic and technical implementation hurdles to cardiac optical mapping. Combined with a red-shifted calcium dye and a new near-infrared voltage-sensitive dye, both suitable for use in blood-perfused tissue, we demonstrate the feasibility of in vivo multi-parametric imaging of the mammalian heart. Our approach combines recording of electrophysiologically-relevant parameters with observation of structural substrates and is adaptable, in principle, to trans-catheter percutaneous approaches. PMID:22876327

  16. A ternary memory module using low-voltage control over optical properties of metal-polypyridyl monolayers.

    Science.gov (United States)

    Kumar, Anup; Chhatwal, Megha; Mondal, Prakash Chandra; Singh, Vikram; Singh, Alok Kumar; Cristaldi, Domenico A; Gupta, Rinkoo D; Gulino, Antonino

    2014-04-14

    A ternary memory module has been designed as a function of precise voltage command. The monolayer based module displays perpetual stability and non-hysteretic reversibility for multiple scans (10(2)). Ternary-state readout provides a vision to integrate the next generation of "smart electro-optical devices" viable for multi-state memory.

  17. Multimodal ophthalmic imaging using spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography

    Science.gov (United States)

    El-Haddad, Mohamed T.; Malone, Joseph D.; Li, Jianwei D.; Bozic, Ivan; Arquitola, Amber M.; Joos, Karen M.; Patel, Shriji N.; Tao, Yuankai K.

    2017-08-01

    Ophthalmic surgery involves manipulation of delicate, layered tissue structures on milli- to micrometer scales. Traditional surgical microscopes provide an inherently two-dimensional view of the surgical field with limited depth perception which precludes accurate depth-resolved visualization of these tissue layers, and limits the development of novel surgical techniques. We demonstrate multimodal swept-source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography (SS-SESLO-OCT) to address current limitations of image-guided ophthalmic microsurgery. SS-SESLO-OCT provides inherently co-registered en face and cross-sectional field-of-views (FOVs) at a line rate of 400 kHz and >2 GPix/s throughput. We show in vivo imaging of the anterior segment and retinal fundus of a healthy volunteer, and preliminary results of multi-volumetric mosaicking for ultrawide-field retinal imaging with 90° FOV. Additionally, a scan-head was rapid-prototyped with a modular architecture which enabled integration of SS-SESLO-OCT with traditional surgical microscope and slit-lamp imaging optics. Ex vivo surgical maneuvers were simulated in cadaveric porcine eyes. The system throughput enabled volumetric acquisition at 10 volumes-per-second (vps) and allowed visualization of surgical dynamics in corneal sweeps, compressions, and dissections, and retinal sweeps, compressions, and elevations. SESLO en face images enabled simple real-time co-registration with the surgical microscope FOV, and OCT cross-sections provided depth-resolved visualization of instrument-tissue interactions. Finally, we demonstrate novel augmented-reality integration with the surgical view using segmentation overlays to aid surgical guidance. SS-SESLO-OCT may benefit clinical diagnostics by enabling aiming, registration, and mosaicking; and intraoperative imaging by allowing for real-time surgical feedback, instrument tracking, and overlays of computationally extracted biomarkers of disease.

  18. Optical waveguide characterization of dielectric films deposited by reactive low-voltage ion plating.

    Science.gov (United States)

    Kimble, T C; Himel, M D; Guenther, K H

    1993-10-01

    We determine the quality of single films of various oxides, which are deposited on thermally oxidized silicon wafers by reactive low-voltage ion plating (RLVIP), by measuring their optical waveguide losses. We use a prism coupler for inserting the radiation of a wavelength-selectable He-Ne laser into the waveguide and a CCD camera for imaging the light scattered from the surface of the films. The waveguide losses of the RLVIP films are typically of the order of 1 to 10 dB/cm. Some data obtained for TiO(2) layers on thermally grown SiO(2) and RLVIP SiO(2) seem to confirm the presence of an absorbing boundary layer between RLVIP SiO(2) and TiO(2) that has been found in SiO(2)-TiO(2) multilayers. The waveguide measurements also reveal unusual index gradients in thick (~ 10 µm) single layers of Al(2)O(3) derived from multimode effective index calculations.

  19. Tuning the defect mode in ternary photonic crystal with external voltage for designing a controllable optical filter

    Science.gov (United States)

    Jamshidi-Ghaleh, Kazem; Rashidi, Shiva; Vahedi, Ali

    2015-09-01

    In this work, behavior of defect mode in one-dimensional ternary photonic crystal (1DTPC) structure with arrangement of (MgF2/Ag/TiO2)5LiNbO3(TiO2/Ag/MgF2)5 was investigated under the applied external electric dc voltage. The defect layer is lithium niobate (LiNbO3), an electro-optical (EO) material whose refractive index is voltage-dependent with high EO coefficient. In comparison, magnesium fluoride (MgF2) and titanium dioxide (TiO2) layers have very low EO coefficients. A narrow localized defect mode with perfect transmittance was appeared inside the photonic band gap. Under applying the positive or negative biases, red shift and blue shift was observed in the defect mode, respectively. More than 120 nm tunability was obtained under externally applied voltage in the range of -200 V to 200 V. The physical interpretation is very simple. Change in optical path-length displaces the localized wavelength of the defect mode due to Bragg interface condition. The externally tunable localized mode can be employed in designing a controllable optical filter, one of the essential devices for new-generation all-optical integrated circuits.

  20. Design of frequency-encoded data-based optical master-slave-JK flip-flop using polarization switch

    Science.gov (United States)

    Mandal, Sumana; Mandal, Dhoumendra; Mandal, Mrinal Kanti; Garai, Sisir Kumar

    2017-06-01

    An optical data processing and communication system provides enormous potential bandwidth and a very high processing speed, and it can fulfill the demands of the present generation. For an optical computing system, several data processing units that work in the optical domain are essential. Memory elements are undoubtedly essential to storing any information. Optical flip-flops can store one bit of optical information. From these flip-flop registers, counters can be developed. Here, the authors proposed an optical master-slave (MS)-JK flip-flop with the help of two-input and three-input optical NAND gates. Optical NAND gates have been developed using semiconductor optical amplifiers (SOAs). The nonlinear polarization switching property of an SOA has been exploited here, and it acts as a polarization switch in the proposed scheme. A frequency encoding technique is adopted for representing data. A specific frequency of an optical signal represents a binary data bit. This technique of data representation is helpful because frequency is the fundamental property of a signal, and it remains unaltered during reflection, refraction, absorption, etc. throughout the data propagation. The simulated results enhance the admissibility of the scheme.

  1. Voltage-controlled enhancement of optical absorption in a graphene monolayer with a one-dimensional photonic crystal

    Science.gov (United States)

    Rao, Wei-Feng; Zhang, Mao-Ting; Zheng, Gai-Ge

    2017-09-01

    The structure of a one-dimensional photonic crystal (1D-PhC) with a graphene-based defect is proposed and investigated to enhance the optical response of graphene in the visible to near-infrared (NIR) wavelength region. An electro-optical (EO) tuning material lithium niobate (LiNbO3, LN) is selected as the spacer layer with an external voltage applied on it. By means of the transfer-matrix method (TMM), the dependence of the absorption characteristics on the incident angle and period numbers is analyzed. The possibility of the resonant wavelength being tunable via the external voltage and thickness of the LN layer is also discussed. It is shown that nearly perfect absorption can be achieved by a certain choice of the period numbers of the 1D-PhC surrounding the defect layer at a specific incidence. The linear relation between the peak wavelength and the applied external voltage is also demonstrated, and it is possible to control the position and number of the resonant wavelengths by varying the voltage and thickness of the LN defect layer.

  2. Construction and use of a zebrafish heart voltage and calcium optical mapping system, with integrated electrocardiogram and programmable electrical stimulation

    Science.gov (United States)

    Lin, Eric; Craig, Calvin; Lamothe, Marcel; Sarunic, Marinko V.; Beg, Mirza Faisal

    2015-01-01

    Zebrafish are increasingly being used as a model of vertebrate cardiology due to mammalian-like cardiac properties in many respects. The size and fecundity of zebrafish make them suitable for large-scale genetic and pharmacological screening. In larger mammalian hearts, optical mapping is often used to investigate the interplay between voltage and calcium dynamics and to investigate their respective roles in arrhythmogenesis. This report outlines the construction of an optical mapping system for use with zebrafish hearts, using the voltage-sensitive dye RH 237 and the calcium indicator dye Rhod-2 using two industrial-level CCD cameras. With the use of economical cameras and a common 532-nm diode laser for excitation, the rate dependence of voltage and calcium dynamics within the atrial and ventricular compartments can be simultaneously determined. At 140 beats/min, the atrial action potential duration was 36 ms and the transient duration was 53 ms. With the use of a programmable electrical stimulator, a shallow rate dependence of 3 and 4 ms per 100 beats/min was observed, respectively. In the ventricle the action potential duration was 109 ms and the transient duration was 124 ms, with a steeper rate dependence of 12 and 16 ms per 100 beats/min. Synchronous electrocardiograms and optical mapping recordings were recorded, in which the P-wave aligns with the atrial voltage peak and R-wave aligns with the ventricular peak. A simple optical pathway and imaging chamber are detailed along with schematics for the in-house construction of the electrocardiogram amplifier and electrical stimulator. Laboratory procedures necessary for zebrafish heart isolation, cannulation, and loading are also presented. PMID:25740339

  3. Optical focusing deep inside dynamic scattering media with near-infrared time-reversed ultrasonically encoded (TRUE) light.

    Science.gov (United States)

    Liu, Yan; Lai, Puxiang; Ma, Cheng; Xu, Xiao; Grabar, Alexander A; Wang, Lihong V

    2015-01-05

    Focusing light deep inside living tissue has not been achieved despite its promise to play a central role in biomedical imaging, optical manipulation and therapy. To address this challenge, internal-guide-star-based wavefront engineering techniques--for example, time-reversed ultrasonically encoded (TRUE) optical focusing--were developed. The speeds of these techniques, however, were limited to no greater than 1 Hz, preventing them from in vivo applications. Here we improve the speed of optical focusing deep inside scattering media by two orders of magnitude, and focus diffuse light inside a dynamic scattering medium having a speckle correlation time as short as 5.6 ms, typical of living tissue. By imaging a target, we demonstrate the first focusing of diffuse light inside a dynamic scattering medium containing living tissue. Since the achieved focusing speed approaches the tissue decorrelation rate, this work is an important step towards in vivo deep tissue noninvasive optical imaging, optogenetics and photodynamic therapy.

  4. Improving the axial resolution in time-reversed ultrasonically encoded (TRUE) optical focusing with dual ultrasonic waves

    Science.gov (United States)

    Yang, Qiang; Xu, Xiao; Lai, Puxiang; Sang, Xinzhu; Wang, Lihong V.

    2014-03-01

    Focusing light inside highly scattering media beyond the ballistic regime is a challenging task in biomedical optical imaging, manipulation, and therapy. This challenge can be overcome by time reversing ultrasonically encoded (TRUE) diffuse light to the ultrasonic focus inside a turbid medium. In TRUE optical focusing, a photorefractive crystal or polymer is used as the phase conjugate mirror for optical time reversal. Accordingly, a relatively long ultrasound burst, whose duration matches the response time of the photorefractive material, is used to encode the diffuse light. With this long ultrasound burst, the resolution of the TRUE focus along the acoustic axis is poor. In this work, we used two transducers, emitting two intersecting ultrasound beams at 3.4 MHz and 3.6 MHz respectively, to modulate the diffuse light within their intersection volume at the beat frequency. We show that light encoded at the beat frequency can be time-reversed and converge to the intersection volume. Experimentally, TRUE focusing with an acoustic axial resolution of ~1.1 mm was demonstrated inside turbid media, agreeing with the theoretical estimation.

  5. High Radiation Tolerant Ceramic Voltage Isolator (Non-optical Gate Driver) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of the Phase I effort is to design, develop and demonstrate a novel solid-state ceramic-based voltage isolator and demonstrate its potential to provide a...

  6. Performance of an optical encoder based on a nondiffractive beam implemented with a specific photodetection integrated circuit and a diffractive optical element.

    Science.gov (United States)

    Quintián, Fernando Perez; Calarco, Nicolás; Lutenberg, Ariel; Lipovetzky, José

    2015-09-01

    In this paper, we study the incremental signal produced by an optical encoder based on a nondiffractive beam (NDB). The NDB is generated by means of a diffractive optical element (DOE). The detection system is composed by an application specific integrated circuit (ASIC) sensor. The sensor consists of an array of eight concentric annular photodiodes, each one provided with a programmable gain amplifier. In this way, the system is able to synthesize a nonuniform detectivity. The contrast, amplitude, and harmonic content of the sinusoidal output signal are analyzed. The influence of the cross talk among the annular photodiodes is placed in evidence through the dependence of the signal contrast on the wavelength.

  7. Congenital Insensitivity To Pain: Fracturing Without Apparent Skeletal Pathobiology Caused By An Autosomal Dominant, Second Mutation in SCN11A Encoding Voltage-Gated Sodium Channel 1.9

    OpenAIRE

    Phatarakijnirund, Voraluck; Mumm, Steven; McAlister, William H.; Novack, Deborah; Wenkert, Deborah; Clements, Karen L.; Whyte, Michael P.

    2015-01-01

    Congenital insensitivity to pain (CIP) comprises the rare heritable disorders without peripheral neuropathy that feature inability to feel pain. Fracturing and joint destruction are common complications, but lack detailed studies of mineral and skeletal homeostasis and bone histology. In 2013, discovery of a heterozygous gain-of-function mutation in SCN11A encoding voltage-gated sodium channel 1.9 (Nav1.9) established a distinctive CIP in three unrelated patients who suffered multiple painles...

  8. Optical and Electrical Performance of MOS-Structure Silicon Solar Cells with Antireflective Transparent ITO and Plasmonic Indium Nanoparticles under Applied Bias Voltage

    Directory of Open Access Journals (Sweden)

    Wen-Jeng Ho

    2016-08-01

    Full Text Available This paper reports impressive improvements in the optical and electrical performance of metal-oxide-semiconductor (MOS-structure silicon solar cells through the incorporation of plasmonic indium nanoparticles (In-NPs and an indium-tin-oxide (ITO electrode with periodic holes (perforations under applied bias voltage. Samples were prepared using a plain ITO electrode or perforated ITO electrode with and without In-NPs. The samples were characterized according to optical reflectance, dark current voltage, induced capacitance voltage, external quantum efficiency, and photovoltaic current voltage. Our results indicate that induced capacitance voltage and photovoltaic current voltage both depend on bias voltage, regardless of the type of ITO electrode. Under a bias voltage of 4.0 V, MOS cells with perforated ITO and plain ITO, respectively, presented conversion efficiencies of 17.53% and 15.80%. Under a bias voltage of 4.0 V, the inclusion of In-NPs increased the efficiency of cells with perforated ITO and plain ITO to 17.80% and 16.87%, respectively.

  9. Optical image transformation and encryption by phase-retrieval-based double random-phase encoding and compressive ghost imaging

    Science.gov (United States)

    Yuan, Sheng; Yang, Yangrui; Liu, Xuemei; Zhou, Xin; Wei, Zhenzhuo

    2018-01-01

    An optical image transformation and encryption scheme is proposed based on double random-phase encoding (DRPE) and compressive ghost imaging (CGI) techniques. In this scheme, a secret image is first transformed into a binary image with the phase-retrieval-based DRPE technique, and then encoded by a series of random amplitude patterns according to the ghost imaging (GI) principle. Compressive sensing, corrosion and expansion operations are implemented to retrieve the secret image in the decryption process. This encryption scheme takes the advantage of complementary capabilities offered by the phase-retrieval-based DRPE and GI-based encryption techniques. That is the phase-retrieval-based DRPE is used to overcome the blurring defect of the decrypted image in the GI-based encryption, and the CGI not only reduces the data amount of the ciphertext, but also enhances the security of DRPE. Computer simulation results are presented to verify the performance of the proposed encryption scheme.

  10. Genetically encoded optical sensors for monitoring of intracellular chloride and chloride-selective channel activity

    Directory of Open Access Journals (Sweden)

    Piotr Bregestovski

    2009-12-01

    Full Text Available This review briefly discusses the main approaches for monitoring chloride (Cl−, the most abundant physiological anion. Noninvasive monitoring of intracellular Cl− ([Cl−]i is a challenging task owing to two main difficulties: (i the low transmembrane ratio for Cl−, approximately 10:1; and (ii the small driving force for Cl−, as the Cl− reversal potential (ECl is usually close to the resting potential of the cells. Thus, for reliable monitoring of intracellular Cl−, one has to use highly sensitive probes. From several methods for intracellular Cl− analysis, genetically encoded chloride indicators represent the most promising tools. Recent achievements in the development of genetically encoded chloride probes are based on the fact that yellow fluorescent protein (YFP exhibits Cl−-sensitivity. YFP-based probes have been successfully used for quantitative analysis of Cl− transport in different cells and for high-throughput screening of modulators of Cl−-selective channels. Development of a ratiometric genetically encoded probe, Clomeleon, has provided a tool for noninvasive estimation of intracellular Cl− concentrations. While the sensitivity of this protein to Cl− is low (EC50 about 160 mM, it has been successfully used for monitoring intracellular Cl− in different cell types. Recently a CFP–YFP-based probe with a relatively high sensitivity to Cl− (EC50 about 30 mM has been developed. This construct, termed Cl-Sensor, allows ratiometric monitoring using the fluorescence excitation ratio. Of particular interest are genetically encoded probes for monitoring of ion channel distribution and activity. A new molecular probe has been constructed by introducing into the cytoplasmic domain of the Cl−-selective glycine receptor (GlyR channel the CFP–YFP-based Cl-Sensor. This construct, termed BioSensor-GlyR, has been successfully expressed in cell lines. The new genetically encoded chloride probes offer means of screening

  11. Low-voltage linear silicon optical modulator with a single-drive parallel-push-pull scheme

    Science.gov (United States)

    Shao, Sizhu; Ding, Jianfeng; Zhang, Lei; Fu, Xin; Yang, Lin

    2018-01-01

    We demonstrate a single-drive parallel-push-pull silicon optical modulator. Compared with the serial-push-pull scheme, the parallel-push-pull scheme allows the driving signal to be applied on both the arms without division. It makes the device suitable for low-voltage driving. Since the electrode drives two PN junctions at the same time, we dope the waveguides periodically in order to lower the capacitance per unit length of the loaded PN junction. This design could alleviate the matching requirement of the coplanar waveguide electrode. When optically biased at the quadrature point, the device has an extinction ratio of 3.1 dB at the speed of 20 Gbps and under the driving voltage of 1.8 Vpp. Benefitting from the push-pull scheme, its linearity performance is also improved. Compared with the device adopting the scheme with only one arm being driven, the spurious free dynamic ranges for second-order harmonic distortion and third-order intermodulation distortion increase by 11.5 dB and 2 dB to 101 dB .Hz 1 / 2 and 113 dB .Hz 2 / 3, respectively.

  12. Design of 10Gbps optical encoder/decoder structure for FE-OCDMA system using SOA and opto-VLSI processors.

    Science.gov (United States)

    Aljada, Muhsen; Hwang, Seow; Alameh, Kamal

    2008-01-21

    In this paper we propose and experimentally demonstrate a reconfigurable 10Gbps frequency-encoded (1D) encoder/decoder structure for optical code division multiple access (OCDMA). The encoder is constructed using a single semiconductor optical amplifier (SOA) and 1D reflective Opto-VLSI processor. The SOA generates broadband amplified spontaneous emission that is dynamically sliced using digital phase holograms loaded onto the Opto-VLSI processor to generate 1D codewords. The selected wavelengths are injected back into the same SOA for amplifications. The decoder is constructed using single Opto-VLSI processor only. The encoded signal can successfully be retrieved at the decoder side only when the digital phase holograms of the encoder and the decoder are matched. The system performance is measured in terms of the auto-correlation and cross-correlation functions as well as the eye diagram.

  13. A Fiber-Optic Sensor for Acoustic Emission Detection in a High Voltage Cable System

    Directory of Open Access Journals (Sweden)

    Tongzhi Zhang

    2016-11-01

    Full Text Available We have proposed and demonstrated a Michelson interferometer-based fiber sensor for detecting acoustic emission generated from the partial discharge (PD of the accessories of a high-voltage cable system. The developed sensor head is integrated with a compact and relatively high sensitivity cylindrical elastomer. Such a sensor has a broadband frequency response and a relatively high sensitivity in a harsh environment under a high-voltage electric field. The design and fabrication of the sensor head integrated with the cylindrical elastomer is described, and a series of experiments was conducted to evaluate the sensing performance. The experimental results demonstrate that the sensitivity of our developed sensor for acoustic detection of partial discharges is 1.7 rad / ( m ⋅ Pa . A high frequency response up to 150 kHz is achieved. Moreover, the relatively high sensitivity for the detection of PD is verified in both the laboratory environment and gas insulated switchgear. The obtained results show the great potential application of a Michelson interferometer-based fiber sensor integrated with a cylindrical elastomer for in-situ monitoring high-voltage cable accessories for safety work.

  14. A Fiber-Optic Sensor for Acoustic Emission Detection in a High Voltage Cable System

    Science.gov (United States)

    Zhang, Tongzhi; Pang, Fufei; Liu, Huanhuan; Cheng, Jiajing; Lv, Longbao; Zhang, Xiaobei; Chen, Na; Wang, Tingyun

    2016-01-01

    We have proposed and demonstrated a Michelson interferometer-based fiber sensor for detecting acoustic emission generated from the partial discharge (PD) of the accessories of a high-voltage cable system. The developed sensor head is integrated with a compact and relatively high sensitivity cylindrical elastomer. Such a sensor has a broadband frequency response and a relatively high sensitivity in a harsh environment under a high-voltage electric field. The design and fabrication of the sensor head integrated with the cylindrical elastomer is described, and a series of experiments was conducted to evaluate the sensing performance. The experimental results demonstrate that the sensitivity of our developed sensor for acoustic detection of partial discharges is 1.7 rad/(m⋅Pa). A high frequency response up to 150 kHz is achieved. Moreover, the relatively high sensitivity for the detection of PD is verified in both the laboratory environment and gas insulated switchgear. The obtained results show the great potential application of a Michelson interferometer-based fiber sensor integrated with a cylindrical elastomer for in-situ monitoring high-voltage cable accessories for safety work. PMID:27916900

  15. An optically coupled power stimulus isolation unit with high voltage and fast rise time output

    Directory of Open Access Journals (Sweden)

    R.O. Brasil

    1999-06-01

    Full Text Available Recent technological developments have created new devices that could improve and simplify the construction of stimulus isolators. HEXFET transistors can switch large currents and hundreds of volts in nanoseconds. The newer opto-isolators can give a pulse rise time of a few nanoseconds, with output compatible with MOSFET devices, in which delays are reduced to nanoseconds. Integrated DC/DC converters are now available. Using these new resources we developed a new electrical stimulus isolator circuit with selectable constant-current and constant-voltage modes, which are precise and easy to construct. The circuit works like a regulated power supply in both modes with output switched to zero or to free mode through an opto-isolator device. The isolator analyses showed good practical performance. The output to ground resistance was 1011 ohms and capacitance 35 picofarads. The rise time and fall time were identical (5 µs and constant. The selectable voltage or current output mode made it very convenient to use. The current mode, with higher output resistance values in low current ranges, permits intracellular stimulation even with tip resistances close to 100 megaohms. The high compliance of 200 V guarantees the value of the current stimulus. The very low output resistance in the voltage mode made the device highly suitable for extracellular stimulation with low impedance electrodes. Most importantly, these characteristics were achieved with a circuit that was easy to build and modify and assembled with components available in Brazil.

  16. An optically coupled power stimulus isolation unit with high voltage and fast rise time output.

    Science.gov (United States)

    Brasil, R O; Leal-Cardoso, J H

    1999-06-01

    Recent technological developments have created new devices that could improve and simplify the construction of stimulus isolators. HEXFET transistors can switch large currents and hundreds of volts in nanoseconds. The newer opto-isolators can give a pulse rise time of a few nanoseconds, with output compatible with MOSFET devices, in which delays are reduced to nanoseconds. Integrated DC/DC converters are now available. Using these new resources we developed a new electrical stimulus isolator circuit with selectable constant-current and constant-voltage modes, which are precise and easy to construct. The circuit works like a regulated power supply in both modes with output switched to zero or to free mode through an opto-isolator device. The isolator analyses showed good practical performance. The output to ground resistance was 10(11) ohms and capacitance 35 picofarads. The rise time and fall time were identical (5 microseconds) and constant. The selectable voltage or current output mode made it very convenient to use. The current mode, with higher output resistance values in low current ranges, permits intracellular stimulation even with tip resistances close to 100 megaohms. The high compliance of 200 V guarantees the value of the current stimulus. The very low output resistance in the voltage mode made the device highly suitable for extracellular stimulation with low impedance electrodes. Most importantly, these characteristics were achieved with a circuit that was easy to build and modify and assembled with components available in Brazil.

  17. Simultaneous multimodal ophthalmic imaging using swept-source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography

    Science.gov (United States)

    Malone, Joseph D.; El-Haddad, Mohamed T.; Bozic, Ivan; Tye, Logan A.; Majeau, Lucas; Godbout, Nicolas; Rollins, Andrew M.; Boudoux, Caroline; Joos, Karen M.; Patel, Shriji N.; Tao, Yuankai K.

    2016-01-01

    Scanning laser ophthalmoscopy (SLO) benefits diagnostic imaging and therapeutic guidance by allowing for high-speed en face imaging of retinal structures. When combined with optical coherence tomography (OCT), SLO enables real-time aiming and retinal tracking and provides complementary information for post-acquisition volumetric co-registration, bulk motion compensation, and averaging. However, multimodality SLO-OCT systems generally require dedicated light sources, scanners, relay optics, detectors, and additional digitization and synchronization electronics, which increase system complexity. Here, we present a multimodal ophthalmic imaging system using swept-source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography (SS-SESLO-OCT) for in vivo human retinal imaging. SESLO reduces the complexity of en face imaging systems by multiplexing spatial positions as a function of wavelength. SESLO image quality benefited from single-mode illumination and multimode collection through a prototype double-clad fiber coupler, which optimized scattered light throughput and reduce speckle contrast while maintaining lateral resolution. Using a shared 1060 nm swept-source, shared scanner and imaging optics, and a shared dual-channel high-speed digitizer, we acquired inherently co-registered en face retinal images and OCT cross-sections simultaneously at 200 frames-per-second. PMID:28101411

  18. Optical focusing deep inside dynamic scattering media with near-infrared time-reversed ultrasonically encoded (TRUE) light

    Science.gov (United States)

    Liu, Yan; Lai, Puxiang; Ma, Cheng; Xu, Xiao; Grabar, Alexander A.; Wang, Lihong V.

    2015-01-01

    Focusing light deep inside living tissue has not been achieved despite its promise to play a central role in biomedical imaging, optical manipulation and therapy. To address this challenge, internal-guide-star-based wavefront engineering techniques—for example, time-reversed ultrasonically encoded (TRUE) optical focusing—were developed. The speeds of these techniques, however, were limited to no greater than 1 Hz, preventing them from in vivo applications. Here we improve the speed of optical focusing deep inside scattering media by two orders of magnitude, and focus diffuse light inside a dynamic scattering medium having a speckle correlation time as short as 5.6 ms, typical of living tissue. By imaging a target, we demonstrate the first focusing of diffuse light inside a dynamic scattering medium containing living tissue. Since the achieved focusing speed approaches the tissue decorrelation rate, this work is an important step towards in vivo deep tissue noninvasive optical imaging, optogenetics and photodynamic therapy.

  19. High-speed time-reversed ultrasonically encoded (TRUE) optical focusing inside dynamic scattering media at 793 nm

    Science.gov (United States)

    Liu, Yan; Lai, Puxiang; Ma, Cheng; Xu, Xiao; Suzuki, Yuta; Grabar, Alexander A.; Wang, Lihong V.

    2014-03-01

    Time-reversed ultrasonically encoded (TRUE) optical focusing is an emerging technique that focuses light deep into scattering media by phase-conjugating ultrasonically encoded diffuse light. In previous work, the speed of TRUE focusing was limited to no faster than 1 Hz by the response time of the photorefractive phase conjugate mirror, or the data acquisition and streaming speed of the digital camera; photorefractive-crystal-based TRUE focusing was also limited to the visible spectral range. These time-consuming schemes prevent this technique from being applied in vivo, since living biological tissue has a speckle decorrelation time on the order of a millisecond. In this work, using a Tedoped Sn2P2S6 photorefractive crystal at a near-infrared wavelength of 793 nm, we achieved TRUE focusing inside dynamic scattering media having a speckle decorrelation time as short as 7.7 ms. As the achieved speed approaches the tissue decorrelation rate, this work is an important step forward toward in vivo applications of TRUE focusing in deep tissue imaging, photodynamic therapy, and optical manipulation.

  20. Multiplex hologram representations of space-variant optical systems using ground-glass encoded reference beams.

    Science.gov (United States)

    Jones, M I; Walkup, J F; Hagler, M O

    1982-04-01

    Multiplex holograms can accurately represent 2-D space-variant optical systems if hologram-to-hologram cross talk can be reduced to an acceptable level. In the experiments reported here the combination of ground-glass diffusers with chirped wave front illumination proved to be an effective means of suppressing this cross talk. The residual cross talk distribution and intensity depend both on the signal and the optical system. The experiments also show that overlapping outputs from multiplexed holograms add coherently in amplitude. In addition, an accurate holographic representation of an extremely space-variant system is presented.

  1. Methods for determining optical power, for power-normalizing laser measurements, and for stabilizing power of lasers via compliance voltage sensing

    Science.gov (United States)

    Taubman, Matthew S; Phillips, Mark C

    2015-04-07

    A method is disclosed for power normalization of spectroscopic signatures obtained from laser based chemical sensors that employs the compliance voltage across a quantum cascade laser device within an external cavity laser. The method obviates the need for a dedicated optical detector used specifically for power normalization purposes. A method is also disclosed that employs the compliance voltage developed across the laser device within an external cavity semiconductor laser to power-stabilize the laser mode of the semiconductor laser by adjusting drive current to the laser such that the output optical power from the external cavity semiconductor laser remains constant.

  2. Irradiation of optically activated SI-GaAs high-voltage switches with low and high energy protons

    CERN Document Server

    Bertolucci, Ennio; Mettivier, G; Russo, P; Bisogni, M G; Bottigli, U; Fantacci, M E; Stefanini, A; Cola, A; Quaranta, F; Vasanelli, L; Stefanini, G

    1999-01-01

    Semi-Insulating Gallium Arsenide (SI-GaAs) devices have been tested for radiation hardness with 3-4 MeV or 24 GeV proton beams. These devices can be operated in dc mode as optically activated electrical switches up to 1 kV. Both single switches (vertical Schottky diodes) and multiple (8) switches (planar devices) have been studied, by analyzing their current-voltage (I-V) reverse characteristics in the dark and under red light illumination, both before and after irradiation. We propose to use them in the system of high-voltage (-600 V) switches for the microstrip gas chambers for the CMS experiment at CERN. Low energy protons (3-4 MeV) were used in order to produce a surface damage below the Schottky contact: their fluence (up to 2.6*10/sup 15/ p/cm/sup 2/) gives a high-dose irradiation. The high energy proton irradiation (energy: 24 GeV, fluence: 1.1*10/sup 14/ p/cm/sup 2/) reproduced a ten years long proton exposure of the devices in CMS experiment conditions. For low energy irradiation, limited changes of ...

  3. Fiber optics for voltage and current measurement; Utilizacion de fibras opticas en la medicion de voltaje y corriente

    Energy Technology Data Exchange (ETDEWEB)

    Mendieta Jimenez, Francisco Javier; Santos Dominguez, Martin; Gutierrez Martinez, Celso [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1988-12-31

    This paper offers a brief revision of the techniques employed in the voltage and current measurement in power plants and mention is made also of its main limitations. Likewise the optical methods of transduction of the mentioned electrical variables indicating their advantages and difficulties for its implementation. Finally the activities developed at the Instituto de Investigaciones Elctricas (IIE) in this field are described. [Espanol] En este trabajo se ofrece una breve revision de las tecnicas utilizadas en la medicion de voltaje y corriente en plantas electricas y se mencionan sus principales limitaciones. Asimismo, se presentan los metodos opticos de transduccion de las variables electricas mencionadas, indicando sus ventajas y las dificultades para su realizacion. Finalmente, se describen las actividades que se desarrollan en el Instituto de Investigaciones Electricas (IIE) en este campo.

  4. Optically induced coherent voltage oscillations in K0.3MoO3

    NARCIS (Netherlands)

    Loosdrecht, P.H.M. van; Beschoten, B.; Dotsenko, I.; Smaalen, S. van

    2002-01-01

    Optical induced transient changes of the electrical conductivity are investigated in the non-linear transport regime of the blue bronze K0.3MoO3 below its Peierls transition using the impulsive infrared excitation of a free-electron laser at energies above the Peierls gap. The transients of the

  5. Optical double image security using random phase fractional Fourier domain encoding and phase-retrieval algorithm

    Science.gov (United States)

    Rajput, Sudheesh K.; Nishchal, Naveen K.

    2017-04-01

    We propose a novel security scheme based on the double random phase fractional domain encoding (DRPE) and modified Gerchberg-Saxton (G-S) phase retrieval algorithm for securing two images simultaneously. Any one of the images to be encrypted is converted into a phase-only image using modified G-S algorithm and this function is used as a key for encrypting another image. The original images are retrieved employing the concept of known-plaintext attack and following the DRPE decryption steps with all correct keys. The proposed scheme is also used for encryption of two color images with the help of convolution theorem and phase-truncated fractional Fourier transform. With some modification, the scheme is extended for simultaneous encryption of gray-scale and color images. As a proof-of-concept, simulation results have been presented for securing two gray-scale images, two color images, and simultaneous gray-scale and color images.

  6. Genetic Encoding of Photocaged Tyrosines with Improved Light-Activation Properties for the Optical Control of Protease Function.

    Science.gov (United States)

    Luo, Ji; Torres-Kolbus, Jessica; Liu, Jihe; Deiters, Alexander

    2017-07-18

    We genetically encoded three new caged tyrosine analogues with improved photochemical properties by using an engineered pyrrolysyl-tRNA synthetase/tRNACUA pair in bacterial and mammalian cells. We applied the new tyrosine analogues to the photoregulation of firefly luciferase by caging its key tyrosine residue, Tyr340, and observed excellent off-to-on light switching. This reporter was then used to evaluate the activation rates of the different light-removable protecting groups in live cells. We identified the nitropiperonyl caging group as an excellent compromise between incorporation efficiency and photoactivation properties. To demonstrate applicability of the new caged tyrosines, an important proteolytic enzyme, tobacco etch virus (TEV) protease, was engineered for optical control. The ability to incorporate differently caged tyrosine analogues into proteins in live cells further expands the unnatural amino acid and optogenetic toolbox. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Multimodal swept-source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography at 400 kHz

    Science.gov (United States)

    El-Haddad, Mohamed T.; Joos, Karen M.; Patel, Shriji N.; Tao, Yuankai K.

    2017-02-01

    Multimodal imaging systems that combine scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT) have demonstrated the utility of concurrent en face and volumetric imaging for aiming, eye tracking, bulk motion compensation, mosaicking, and contrast enhancement. However, this additional functionality trades off with increased system complexity and cost because both SLO and OCT generally require dedicated light sources, galvanometer scanners, relay and imaging optics, detectors, and control and digitization electronics. We previously demonstrated multimodal ophthalmic imaging using swept-source spectrally encoded SLO and OCT (SS-SESLO-OCT). Here, we present system enhancements and a new optical design that increase our SS-SESLO-OCT data throughput by >7x and field-of-view (FOV) by >4x. A 200 kHz 1060 nm Axsun swept-source was optically buffered to 400 kHz sweep-rate, and SESLO and OCT were simultaneously digitized on dual input channels of a 4 GS/s digitizer at 1.2 GS/s per channel using a custom k-clock. We show in vivo human imaging of the anterior segment out to the limbus and retinal fundus over a >40° FOV. In addition, nine overlapping volumetric SS-SESLO-OCT volumes were acquired under video-rate SESLO preview and guidance. In post-processing, all nine SESLO images and en face projections of the corresponding OCT volumes were mosaicked to show widefield multimodal fundus imaging with a >80° FOV. Concurrent multimodal SS-SESLO-OCT may have applications in clinical diagnostic imaging by enabling aiming, image registration, and multi-field mosaicking and benefit intraoperative imaging by allowing for real-time surgical feedback, instrument tracking, and overlays of computationally extracted image-based surrogate biomarkers of disease.

  8. Neuronal encoding of object and distance information: A model simulation study on naturalistic optic flow processing

    Directory of Open Access Journals (Sweden)

    Patrick eHennig

    2012-03-01

    Full Text Available We developed a model of the input circuitry of the FD1 cell, an identified motion-sensitive interneuron in the blowfly’s visual system. The model circuit successfully reproduces the FD1 cell’s most conspicuous property: Its larger responses to objects than to spatially extended patterns. The model circuit also mimics the time-dependent responses of FD1 to dynamically complex naturalistic stimuli, shaped by the blowfly’s saccadic flight and gaze strategy: The FD1 responses are enhanced when, as a consequence of self-motion, a nearby object crosses the receptive field during intersaccadic intervals. Moreover, the model predicts that these object-induced responses are superimposed by pronounced pattern-dependent fluctuations during movements on virtual test flights in a three-dimensional environment with systematic modifications of the environmental patterns. Hence, the FD1 cell is predicted to detect not unambiguously objects defined by the spatial layout of the environment, but to be also sensitive to objects distinguished by textural features. These ambiguous detection abilities suggest an encoding of information about objects - irrespective of the features by which the objects are defined - by a population of cells, with the FD1 cell presumably playing a prominent role in such an ensemble.

  9. Spatial resolution and cathodoluminescence intensity dependence on acceleration voltage in electron beam excitation assisted optical microscopy using Y2O3:Eu3+ film.

    Science.gov (United States)

    Masuda, Yu; Kamiya, Masashi; Sugita, Atsushi; Inami, Wataru; Kawata, Yoshimasa; Kominami, Hiroko; Nakanishi, Yoichiro

    2017-11-01

    This study presents relationship between acceleration voltage and spatial resolution of electron-beam assisted (EXA) optical microscope. The nanometric illumination light sources of the present EXA microscope was red-emitting cathodoluminescence (CL) in the Y2O3:Eu3+ thin film excited by focused electron beam. Our experimental results demonstrated that the spatial resolutions of the EXA microscope were higher as the acceleration voltage was higher. We managed to make images of the scattered gold particles with approximately 90 nm-resolutions at the voltages higher than 20 kV. The dependence of the spatial resolution on the acceleration voltage was explained by the distribution of simulated electron scattering trajectories in the luminescent thin film. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Optical properties of voltage sensitive hemicyanine dyes of variable hydrophobicity confined within surfactant micelles

    Science.gov (United States)

    Naeem, Kashif; Naseem, Bushra; Shah, S. S.; Shah, Syed W. H.

    2017-11-01

    The optical properties of amphiphilic hemicyanine dyes with variable hydrophobicity, confined within anionic micelles of sodium dodecylbenzenesulfonate (NaDDBS) have been studied by UV–visible absorption spectroscopy. The confinement constant, K conf has been determined for each entrapped dye. The ion-pair formation between dye and surfactant causes a decline in electronic transition energy (ΔE T) when dye alkyl chains are smaller due to stabilization of both the ground and excited state. ΔE T values gradually increase with increase in dye hydrophobicity that hampers the electrostatic interaction with dialkylammonium moiety and consequently excited state stabilization is compromised. The average number of dye molecules trapped in a single micelle was also determined. The negative values of Gibbs free energy indicate that the dye entrapment within micelles is energetically favored. These findings have significance for developing functional materials with peculiar luminescent properties, especially for more effective probing of complex biological systems.

  11. Voltages and electric currents mensuration - class 15 kV - for systems electro-optical and magneto-optical; Medicao de tensoes e correntes - classe 15 kv - por sistemas eletro-opticos e magneto-opticos

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Marcos Rodrigues

    1996-07-01

    The technical feasibility of the development of a novel system measuring of high voltage and current in 15 kV distribution lines was presented. The system is basically the combination of two other systems, one conventional and other electro-optical. The conventional subsystem is based on voltage dividers and magnetic rings while the electro-optical subsystem uses LEDs, resistors, optical-fibers and photodetectors. The system was completely tested in laboratory and its main characteristics are low price, easy of installation and flexibility. Two software for data acquisition by GPIB and A/D boards were also developed. The can provide reports on voltages, currents, power and phase-power. (author)

  12. Imaging Voltage in Genetically Defined Neuronal Subpopulations with a Cre Recombinase-Targeted Hybrid Voltage Sensor.

    Science.gov (United States)

    Bayguinov, Peter O; Ma, Yihe; Gao, Yu; Zhao, Xinyu; Jackson, Meyer B

    2017-09-20

    Genetically encoded voltage indicators create an opportunity to monitor electrical activity in defined sets of neurons as they participate in the complex patterns of coordinated electrical activity that underlie nervous system function. Taking full advantage of genetically encoded voltage indicators requires a generalized strategy for targeting the probe to genetically defined populations of cells. To this end, we have generated a mouse line with an optimized hybrid voltage sensor (hVOS) probe within a locus designed for efficient Cre recombinase-dependent expression. Crossing this mouse with Cre drivers generated double transgenics expressing hVOS probe in GABAergic, parvalbumin, and calretinin interneurons, as well as hilar mossy cells, new adult-born neurons, and recently active neurons. In each case, imaging in brain slices from male or female animals revealed electrically evoked optical signals from multiple individual neurons in single trials. These imaging experiments revealed action potentials, dynamic aspects of dendritic integration, and trial-to-trial fluctuations in response latency. The rapid time response of hVOS imaging revealed action potentials with high temporal fidelity, and enabled accurate measurements of spike half-widths characteristic of each cell type. Simultaneous recording of rapid voltage changes in multiple neurons with a common genetic signature offers a powerful approach to the study of neural circuit function and the investigation of how neural networks encode, process, and store information. SIGNIFICANCE STATEMENT Genetically encoded voltage indicators hold great promise in the study of neural circuitry, but realizing their full potential depends on targeting the sensor to distinct cell types. Here we present a new mouse line that expresses a hybrid optical voltage sensor under the control of Cre recombinase. Crossing this line with Cre drivers generated double-transgenic mice, which express this sensor in targeted cell types. In

  13. A straightforward electro-optic polymer covered titanium dioxide strip line modulator with a low driving voltage

    Science.gov (United States)

    Qiu, Feng; Spring, Andrew M.; Maeda, Daisuke; Ozawa, Masa-aki; Odoi, Keisuke; Aoki, Isao; Otomo, Akira; Yokoyama, Shiyoshi

    2014-08-01

    An electro-optic (EO) modulator composed of an EO polymer/titanium dioxide (TiO2) hybrid waveguide has been designed and fabricated. By using a TiO2 strip line (0.3 × 0.3 μm2 cross-section) as the core, the confinement factor in the EO polymer is optimized, thus achieving a high EO activity. The coplanar electrode spacing is tuned to enable an effective poling and a small propagation loss. The measured in-device EO coefficient is 100 pm/V at 1550 nm, with a driving voltage (Vπ) 3.2 V for the 12 mm-electrode length. The results also predict a possible Vπ of ˜1 V in a push-pull MZI structure. The EO activity of the modulator exhibited an excellent temporal stability at 85 °C for 500 h due to the high glass transition temperature of the EO polymer and the temperature-insensitive TiO2 strip line.

  14. An encoding device and a method of encoding

    DEFF Research Database (Denmark)

    2012-01-01

    The present invention relates to an encoding device, such as an optical position encoder, for encoding input from an object, and a method for encoding input from an object, for determining a position of an object that interferes with light of the device. The encoding device comprises a light source...... in the area in the space and may interfere with the light, which interference may be encoded into a position or activation....

  15. Sol-Gel Material-Enabled Electro-Optic Polymer Modulators

    OpenAIRE

    Roland Himmelhuber; Norwood, Robert A.; Yasufumi Enami; Nasser Peyghambarian

    2015-01-01

    Sol-gels are an important material class, as they provide easy modification of material properties, good processability and are easy to synthesize. In general, an electro-optic (EO) modulator transforms an electrical signal into an optical signal. The incoming electrical signal is most commonly information encoded in a voltage change. This voltage change is then transformed into either a phase change or an intensity change in the light signal. The less voltage needed to drive the modulator an...

  16. Multi-volumetric registration and mosaicking using swept-source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography

    Science.gov (United States)

    Bozic, Ivan; El-Haddad, Mohamed T.; Malone, Joseph D.; Joos, Karen M.; Patel, Shriji N.; Tao, Yuankai K.

    2017-02-01

    Ophthalmic diagnostic imaging using optical coherence tomography (OCT) is limited by bulk eye motions and a fundamental trade-off between field-of-view (FOV) and sampling density. Here, we introduced a novel multi-volumetric registration and mosaicking method using our previously described multimodal swept-source spectrally encoded scanning laser ophthalmoscopy and OCT (SS-SESLO-OCT) system. Our SS-SESLO-OCT acquires an entire en face fundus SESLO image simultaneously with every OCT cross-section at 200 frames-per-second. In vivo human retinal imaging was performed in a healthy volunteer, and three volumetric datasets were acquired with the volunteer moving freely and refixating between each acquisition. In post-processing, SESLO frames were used to estimate en face rotational and translational motions by registering every frame in all three volumetric datasets to the first frame in the first volume. OCT cross-sections were contrast-normalized and registered axially and rotationally across all volumes. Rotational and translational motions calculated from SESLO frames were applied to corresponding OCT B-scans to compensate for interand intra-B-scan bulk motions, and the three registered volumes were combined into a single interpolated multi-volumetric mosaic. Using complementary information from SESLO and OCT over serially acquired volumes, we demonstrated multivolumetric registration and mosaicking to recover regions of missing data resulting from blinks, saccades, and ocular drifts. We believe our registration method can be directly applied for multi-volumetric motion compensation, averaging, widefield mosaicking, and vascular mapping with potential applications in ophthalmic clinical diagnostics, handheld imaging, and intraoperative guidance.

  17. Measurement of the internal stress and electric field in a resonating piezoelectric transformer for high-voltage applications using the electro-optic and photoelastic effects.

    Science.gov (United States)

    VanGordon, James A; Kovaleski, Scott D; Norgard, Peter; Gall, Brady B; Dale, Gregory E

    2014-02-01

    The high output voltages from piezoelectric transformers are currently being used to accelerate charged particle beams for x-ray and neutron production. Traditional methods of characterizing piezoelectric transformers (PTs) using electrical probes can decrease the voltage transformation ratio of the device due to the introduction of load impedances on the order of hundreds of kiloohms to hundreds of megaohms. Consequently, an optical diagnostic was developed that used the photoelastic and electro-optic effects present in piezoelectric materials that are transparent to a given optical wavelength to determine the internal stress and electric field. The combined effects of the piezoelectric, photoelastic, and electro-optic effects result in a time-dependent change the refractive indices of the material and produce an artificially induced, time-dependent birefringence in the piezoelectric material. This induced time-dependent birefringence results in a change in the relative phase difference between the ordinary and extraordinary wave components of a helium-neon laser beam. The change in phase difference between the wave components was measured using a set of linear polarizers. The measured change in phase difference was used to calculate the stress and electric field based on the nonlinear optical properties, the piezoelectric constitutive equations, and the boundary conditions of the PT. Maximum stresses of approximately 10 MPa and electric fields of as high as 6 kV/cm were measured with the optical diagnostic. Measured results were compared to results from both a simple one-dimensional (1D) model of the piezoelectric transformer and a three-dimensional (3D) finite element model. Measured stresses and electric fields along the length of an operating length-extensional PT for two different electrical loads were within at least 50 % of 3D finite element simulated results. Additionally, the 3D finite element results were more accurate than the results from the 1D model

  18. Measurement of the internal stress and electric field in a resonating piezoelectric transformer for high-voltage applications using the electro-optic and photoelastic effects

    Science.gov (United States)

    VanGordon, James A.; Kovaleski, Scott D.; Norgard, Peter; Gall, Brady B.; Dale, Gregory E.

    2014-02-01

    The high output voltages from piezoelectric transformers are currently being used to accelerate charged particle beams for x-ray and neutron production. Traditional methods of characterizing piezoelectric transformers (PTs) using electrical probes can decrease the voltage transformation ratio of the device due to the introduction of load impedances on the order of hundreds of kiloohms to hundreds of megaohms. Consequently, an optical diagnostic was developed that used the photoelastic and electro-optic effects present in piezoelectric materials that are transparent to a given optical wavelength to determine the internal stress and electric field. The combined effects of the piezoelectric, photoelastic, and electro-optic effects result in a time-dependent change the refractive indices of the material and produce an artificially induced, time-dependent birefringence in the piezoelectric material. This induced time-dependent birefringence results in a change in the relative phase difference between the ordinary and extraordinary wave components of a helium-neon laser beam. The change in phase difference between the wave components was measured using a set of linear polarizers. The measured change in phase difference was used to calculate the stress and electric field based on the nonlinear optical properties, the piezoelectric constitutive equations, and the boundary conditions of the PT. Maximum stresses of approximately 10 MPa and electric fields of as high as 6 kV/cm were measured with the optical diagnostic. Measured results were compared to results from both a simple one-dimensional (1D) model of the piezoelectric transformer and a three-dimensional (3D) finite element model. Measured stresses and electric fields along the length of an operating length-extensional PT for two different electrical loads were within at least 50 % of 3D finite element simulated results. Additionally, the 3D finite element results were more accurate than the results from the 1D model

  19. Real-time transmission of 3 Gb/s 16-QAM encoded optical OFDM signals over 75 km SMFs with negative power penalties.

    Science.gov (United States)

    Jin, X Q; Giddings, R P; Tang, J M

    2009-08-17

    Real-time optical orthogonal frequency division multiplexing (OOFDM) transceivers are experimentally demonstrated with advanced pilot subcarrier-assisted channel estimation being implemented. The channel estimation technique is, for the first time, proposed and experimentally verified rigorously, which offers a number of unique features including high accuracy, low complexity, small pilot bandwidth usage, excellent stability and buffer-free data flow. The fastest ever real-time end-to-end transmission of 3 Gb/s 16-QAM-encoded OOFDM signals over 75 km MetroCor single-mode fibres is achieved with negative power penalties of -2dB at BERs of 1.0 x 10(-4) in directly modulated DFB laser-based, intensity-modulation and direct-detection systems without in-line optical amplification and chromatic dispersion compensation. (c) 2009 Optical Society of America

  20. Feedback-induced voltage change of a Vertical-Cavity Surface-Emitting Laser as an active detection system for miniature optical scanning probe microscopes.

    Science.gov (United States)

    Heinis, Dominique; Gorecki, Christophe; Bargiel, Sylwester; Cretin, Bernard

    2006-04-17

    We propose a novel detection technique for scanning probe microscopy based on the measuring of the feedback-induced voltage change of 780-nm VCSEL operating at constant current in far-field regime when we modulate mechanically the length of a coupled-cavity generating the feedback conditions. The voltage change of the VCSEL is produced by light back reflected from the sample to the laser cavity. Two-dimensional image probing is successfully demonstrated with high temporal resolution, offering a viable solution for miniature parallel scanning probe optical microscopes, such as confocal microscope, where the use of a photodetector is avoided. This approach opens the possibility to perform imaging tasks in a low cost and hand-held miniature device with much improved effective-space.

  1. Combining Holographic Optical Tweezers with Upconversion Luminescence Encoding: Imaging-Based Stable Suspension Array for Sensitive Responding of Dual Cancer Biomarkers.

    Science.gov (United States)

    Li, Cheng-Yu; Cao, Di; Qi, Chu-Bo; Kang, Ya-Feng; Song, Chong-Yang; Xu, Dang-Dang; Zheng, Bei; Pang, Dai-Wen; Tang, Hong-Wu

    2018-02-06

    Establishment of a stable analytical methodology with high-quality results is an urgent need for screening cancer biomarkers in early diagnosis of cancer. In this study, we incorporate holographic optical tweezers with upconversion luminescence encoding to design an imageable suspension array and apply it to conduct the detection of two liver cancer related biomarkers, carcinoembryonic antigen and alpha fetal protein. This bead-based assay is actualized by forming a bead array with holographic optical tweezers and synchronously exciting the upconversion luminescence of corresponding trapped complex beads fabricated with a simple one-step sandwich immunological recognition. Owing to the fact that these flowing beads are stably trapped in the focal plane of the objective lens which tightly converges the array of the laser beams by splitting a 980 nm beam using a diffraction optical element, a fairly stable excitation condition is achieved to provide reliable assay results. By further taking advantage of the eminent encoding capability of upconversion nanoparticles and the extremely low background signals of anti-Stokes luminescence, the two targets are well-identified and simultaneously detected with quite sound sensitivity and specificity. Moreover, the potential on-demand clinical application is presented by employing this approach to respond the targets toward complex matrices such as serum and tissue samples, offering a new alternative for cancer diagnosis technology.

  2. Encoding of naturalistic optic flow by motion sensitive neurons of nucleus rotundus in the zebra finch (Taeniopygia guttata.

    Directory of Open Access Journals (Sweden)

    Dennis eEckmeier

    2013-09-01

    Full Text Available The retinal image changes that occur during locomotion, the optic flow, carry information about self-motion and the three-dimensional structure of the environment. Especially fast moving animals with only little binocular vision depend on these depth cues for manoeuvring. They actively control their gaze to facilitate perception of depth based on cues in the optic flow. In the visual system of birds, nucleus rotundus neurons were originally found to respond to object motion but not to background motion. However, when background and object were both moving, responses increase the more the direction and velocity of object and background motion on the retina differed. These properties may play a role in representing depth cues in the optic flow. We therefore investigated how neurons in nucleus rotundus respond to optic flow that contains depth cues. We presented simplified and naturalistic optic flow on a panoramic LED display while recording from single neurons in nucleus rotundus of anaesthetized zebra finches. Unlike most studies on motion vision in birds, our stimuli included depth information.We found extensive responses of motion selective neurons in nucleus rotundus to optic flow stimuli. Simplified stimuli revealed preferences for optic flow reflecting translational or rotational self-motion. Naturalistic optic flow stimuli elicited complex response modulations, but the presence of objects was signalled by only few neurons. The neurons that did respond to objects in the optic flow, however, show interesting properties.

  3. A Mach-Zehnder interferometer electro-optic switch with ultralow voltage-length product using poled-polymer/silicon slot waveguide

    Science.gov (United States)

    Huang, Xiao-liang; Li, Cui-ting; Dang, Pei-pei; Zheng, Chuan-tao

    2015-07-01

    By using poled-polymer/silicon slot waveguides in the active region and the Pockels effect of the poled-polymer, we propose a kind of Mach-Zehnder interferometer (MZI) electro-optic (EO) switch operated at 1 550 nm. Structural parameters are optimized for realizing normal switching function. Dependencies of switching characteristics on the slot waveguide parameters are investigated. For the silicon strip with dimension of 170 nm×300 nm, as the slot width varies from 50 nm to 100 nm, the switching voltage can be as low as 1.0 V with active region length of only 0.17-0.35 mm, and the length of the whole device is only about 770-950 μm. The voltage-length product of this switching structure is only 0.17-0.35 V·mm, and it is at least 19-40 times smaller than that of the traditional polymer MZI EO switch, which is 6.69 V·mm. Compared with our previously reported MZI EO switches, this switch exhibits some superior characteristics, including low switching voltage, compact device size and small wavelength dependency.

  4. Development of Optic Neuropathy and Foveal Pseudocyst in a Case of High-Voltage Electrical Injury: A Three-Year Follow-Up

    Directory of Open Access Journals (Sweden)

    Sezin Akça Bayar

    2014-10-01

    Full Text Available A 35-year-old male patient had a decreased vision in his right eye, with a visual acuity of 20/400, after a high-voltage electrical injury. Corneal edema, Descemet’s membrane folds, cataract, macular hole, and optic neuropathy were detected in his right eye. Intravenous pulse steroids were administered. On the third day of treatment, the visual acuity in the right eye improved to 20/200 and the corneal edema resolved. Two months later, the patient’s visual acuity was still 20/200, while optic disc pallor, epiretinal gliosis, a non-fullthickness macular hole, and pseudo-cyst formation were detected in his right eye. Three years later, the macular pseudo-cyst formation transformed into an atrophic scar, while the patient’s visual acuity was the same. In conclusion, as a result of high-voltage electrical injury, serious ocular complications may develop. It is sufficient to refer those patients to an ophthalmologist for appropriate treatment and follow-up. (Turk J Ophthalmol 2014; 44: 410-2

  5. Spatially multiplexed orbital-angular-momentum-encoded single photon and classical channels in a free-space optical communication link.

    Science.gov (United States)

    Ren, Yongxiong; Liu, Cong; Pang, Kai; Zhao, Jiapeng; Cao, Yinwen; Xie, Guodong; Li, Long; Liao, Peicheng; Zhao, Zhe; Tur, Moshe; Boyd, Robert W; Willner, Alan E

    2017-12-01

    We experimentally demonstrate spatial multiplexing of an orbital angular momentum (OAM)-encoded quantum channel and a classical Gaussian beam with a different wavelength and orthogonal polarization. Data rates as large as 100 MHz are achieved by encoding on two different OAM states by employing a combination of independently modulated laser diodes and helical phase holograms. The influence of OAM mode spacing, encoding bandwidth, and interference from the co-propagating Gaussian beam on registered photon count rates and quantum bit error rates is investigated. Our results show that the deleterious effects of intermodal crosstalk effects on system performance become less important for OAM mode spacing Δ≥2 (corresponding to a crosstalk value of less than -18.5  dB). The use of OAM domain can additionally offer at least 10.4 dB isolation besides that provided by wavelength and polarization, leading to a further suppression of interference from the classical channel.

  6. Engineering and characterization of an enhanced fluorescent protein voltage sensor.

    Directory of Open Access Journals (Sweden)

    Dimitar Dimitrov

    Full Text Available BACKGROUND: Fluorescent proteins have been used to generate a variety of biosensors to optically monitor biological phenomena in living cells. Among this class of genetically encoded biosensors, reporters for membrane potential have been a particular challenge. The use of presently known voltage sensor proteins is limited by incorrect subcellular localization and small or absent voltage responses in mammalian cells. RESULTS: Here we report on a fluorescent protein voltage sensor with superior targeting to the mammalian plasma membrane and high responsiveness to membrane potential signaling in excitable cells. CONCLUSIONS AND SIGNIFICANCE: This biosensor, which we termed VSFP2.1, is likely to lead to new methods of monitoring electrically active cells with cell type specificity, non-invasively and in large numbers, simultaneously.

  7. Second and third generation voltage-sensitive fluorescent proteins for monitoring membrane potential

    Directory of Open Access Journals (Sweden)

    Amelie Perron

    2009-06-01

    Full Text Available Over the last decade, optical neuroimaging methods have been enriched by engineered biosensors derived from fluorescent protein (FP reporters fused to protein detectors that convert physiological signals into changes of intrinsic FP fluorescence. These FP-based indicators are genetically encoded, and hence targetable to specific cell populations within networks of heterologous cell types. Among this class of biosensors, the development of optical probes for membrane potential is both highly desirable and challenging. A suitable FP voltage sensor would indeed be a valuable tool for monitoring the activity of thousands of individual neurons simultaneously in a non-invasive manner. Previous prototypic genetically-encoded FP voltage indicators achieved a proof of principle but also highlighted several difficulties such as poor cell surface targeting and slow kinetics. Recently, we developed a new series of FRET-based Voltage-Sensitive Fluorescent Proteins (VSFPs, referred to as VSFP2s, with efficient targeting to the plasma membrane and high responsiveness to membrane potential signaling in excitable cells. In addition to these FRET-based voltage sensors, we also generated a third series of probes consisting of single FPs with response kinetics suitable for the optical imaging of fast neuronal signals. These newly available genetically-encoded reporters for membrane potential will be instrumental for future experimental approaches directed toward the understanding of neuronal network dynamics and information processing in the brain. Here, we review the development and current status of these novel fluorescent probes.

  8. A single-shot, multiwavelength electro-optic data-acquisition system for inertial confinement fusion applications (invited).

    Science.gov (United States)

    Donaldson, W R; Zhao, C; Ji, L; Roides, R G; Miller, K; Beeman, B

    2012-10-01

    Electro-optic data-acquisition systems encode the output from voltage-history diagnostics onto optical signals. The optical signals can propagate long distances over fiber-optic links without degrading the bandwidth of the encoded signal while protecting the recording electronics from overvoltage damage. The sinusoidal response and tolerance to high-input voltages of the Mach-Zehnder modulator used for the encoding leads to the additional advantage of a high dynamic range and a reduced need for manually swapping attenuators. We have demonstrated a single-shot, electro-optic data-acquisition system with a 600:1 dynamic range. This system provides optical isolation and a bandwidth of 6 GHz. The prototype system uses multiple optical wavelengths to allow for the multiplexing of up to eight signals onto one photodetector.

  9. Improve the performance of orthogonal ASK/DPSK optical label switching by DC-balanced line encoding

    DEFF Research Database (Denmark)

    Chi, Nan; Xu, Lin; Zhang, J.

    2006-01-01

    Orthogonal amplitude shift keying/differential phase-shift keying (ASK/DPSK) labeling is a promising approach to ultrahigh packet-rate routing and forwarding in the optical layer. However, the limitation on the payload extinction ratio (ER) is a detrimental effect for network scalability and tran...

  10. voltage-dependent fluorescent indicator for optogenetic applications, archaerhodopsin-3: Structure and optical properties from in silico modeling [version 2; referees: 1 approved, 2 approved with reservations

    Directory of Open Access Journals (Sweden)

    Dmitrii M. Nikolaev

    2017-01-01

    Full Text Available It was demonstrated in recent studies that some rhodopsins can be used in optogenetics as fluorescent indicators of membrane voltage. One of the promising candidates for these applications is archaerhodopsin-3. However, the fluorescent signal for wild-type achaerhodopsin-3 is not strong enough for real applications. Rational design of mutants with an improved signal is an important task, which requires both experimental and theoretical studies. Herein, we used a homology-based computational approach to predict the three-dimensional structure of archaerhodopsin-3, and a Quantum Mechanics/Molecular Mechanics (QM/MM hybrid approach with high-level multireference ab initio methodology (SORCI+Q/AMBER to model optical properties of this protein. We demonstrated that this methodology allows for reliable prediction of structure and spectral properties of archaerhodopsin-3. The results of this study can be utilized for computational molecular design of efficient fluorescent indicators of membrane voltage for modern optogenetics on the basis of archaerhodopsin-3.

  11. The role of cathodic current in PEO of aluminum: Influence of cationic electrolyte composition on the transient current-voltage curves and the discharges optical emission spectra

    Science.gov (United States)

    Rogov, A. B.; Shayapov, V. R.

    2017-02-01

    In this paper, the influence of cationic electrolytes composition on electrical and optical responses of plasma electrolytic oxidation process of A1050 aluminum alloy under alternating polarization is considered. The electrolytes consist of 0.1 M boric acid with addition of one of the following hydroxides: LiOH, NaOH, KOH, tetraethylammonium hydroxide, Ca(OH)2 up to pH value 9.2. Coatings microstructure, elemental and phase compositions were studied by SEM, EDS and XRD. It was shown that the hysteresis of anodic current-voltage curve (specific feature of "Soft sparking" PEO) was clear observed in the presence of sodium and potassium cations. It was found that composition of microdischarges plasma is also affected by the nature of the cations. It was shown that there are a number of reciprocal processes, which take place under anodic and cathodic polarization.

  12. Analog time-reversed ultrasonically encoded light focusing inside scattering media with a 33,000× optical power gain.

    Science.gov (United States)

    Ma, Cheng; Xu, Xiao; Wang, Lihong V

    2015-03-10

    Recent breakthrough in wavefront engineering shows great promises in controlling light propagation inside scattering media. At present, the digital approaches enjoy high gain, while their speeds are slow because of high data throughputs. In contrast, the analog approaches are intrinsically fast but suffer from poor efficiencies and small gains. Further improvements in both speed and gain are necessary to advance the existing technologies toward real-world applications. Here, we report analog time-reversal of acousto-optically tagged photons with a flux amplification of over 33,000 times (45 dB) at a target location inside scattering media. Such a substantial power gain enhancement is achieved when the temporal width of the time-reversed photon packet is squeezed below the carrier-recombination-limited hologram decay time in a photorefractive crystal. Despite a focusing energy gain below unity, the unprecedented power gain is expected to enable new optical imaging, sensing, manipulation and treatment applications.

  13. Imaging voltage in neurons

    Science.gov (United States)

    Peterka, Darcy S.; Takahashi, Hiroto; Yuste, Rafael

    2011-01-01

    In the last decades, imaging membrane potential has become a fruitful approach to study neural circuits, especially in invertebrate preparations with large, resilient neurons. At the same time, particularly in mammalian preparations, voltage imaging methods suffer from poor signal to noise and secondary side effects, and they fall short of providing single-cell resolution when imaging of the activity of neuronal populations. As an introduction to these techniques, we briefly review different voltage imaging methods (including organic fluorophores, SHG chromophores, genetic indicators, hybrid, nanoparticles and intrinsic approaches), and illustrate some of their applications to neuronal biophysics and mammalian circuit analysis. We discuss their mechanisms of voltage sensitivity, from reorientation, electrochromic or electro-optical phenomena, to interaction among chromophores or membrane scattering, and highlight their advantages and shortcomings, commenting on the outlook for development of novel voltage imaging methods. PMID:21220095

  14. Fractional Fourier domain optical image hiding using phase retrieval algorithm based on iterative nonlinear double random phase encoding.

    Science.gov (United States)

    Wang, Xiaogang; Chen, Wen; Chen, Xudong

    2014-09-22

    We present a novel image hiding method based on phase retrieval algorithm under the framework of nonlinear double random phase encoding in fractional Fourier domain. Two phase-only masks (POMs) are efficiently determined by using the phase retrieval algorithm, in which two cascaded phase-truncated fractional Fourier transforms (FrFTs) are involved. No undesired information disclosure, post-processing of the POMs or digital inverse computation appears in our proposed method. In order to achieve the reduction in key transmission, a modified image hiding method based on the modified phase retrieval algorithm and logistic map is further proposed in this paper, in which the fractional orders and the parameters with respect to the logistic map are regarded as encryption keys. Numerical results have demonstrated the feasibility and effectiveness of the proposed algorithms.

  15. Congenital insensitivity to pain: Fracturing without apparent skeletal pathobiology caused by an autosomal dominant, second mutation in SCN11A encoding voltage-gated sodium channel 1.9.

    Science.gov (United States)

    Phatarakijnirund, Voraluck; Mumm, Steven; McAlister, William H; Novack, Deborah V; Wenkert, Deborah; Clements, Karen L; Whyte, Michael P

    2016-03-01

    Congenital insensitivity to pain (CIP) comprises the rare heritable disorders without peripheral neuropathy that feature inability to feel pain. Fracturing and joint destruction are common complications, but lack detailed studies of mineral and skeletal homeostasis and bone histology. In 2013, discovery of a heterozygous gain-of-function mutation in SCN11A encoding voltage-gated sodium channel 1.9 (Nav1.9) established a distinctive CIP in three unrelated patients who suffered multiple painless fractures, self-inflicted mutilation, chronic diarrhea, and hyperhidrosis. Here, we studied a mother and two children with CIP by physical examination, biochemical testing, radiological imaging including DXA, iliac crest histology, and mutation analysis. She suffered fractures primarily of her lower extremities beginning at age two years, and had Charcot deformity of both ankles and joint hypermobility. Nerve conduction velocity together with electromyography were normal. Her children had recurrent major fractures beginning in early childhood, joint hypermobility, and chronic diarrhea. She had an excoriated external nare, and both children had hypertrophic scars from scratching. Skin collagen studies were normal. Radiographs revealed fractures and deformities. However, lumbar spine and total hip BMD Z-scores, biochemical parameters of mineral and skeletal homeostasis, and iliac crest histology of the mother (after in vivo tetracycline labeling) were normal. Genomic DNA from the children revealed a unique heterozygous missense mutation in exon 23 (c.3904C>T, p.Leu1302Phe) of SCN11A that is absent in SNP databases and alters an evolutionarily conserved amino acid. This autosomal dominant CIP reflects the second gain-of-function mutation of SCN11A. Perhaps joint hypermobility is an unreported feature. How mutation of Nav1.9 causes fracturing remains unexplained. Lack of injury awareness is typically offered as the reason, and was supported by our unremarkable biochemical

  16. Modular multimodal swept-source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography scan-head for surgical microscope-integrated and slit-lamp imaging

    Science.gov (United States)

    Malone, Joseph D.; Li, Jianwei D.; El-Haddad, Mohamed T.; Joos, Karen M.; Patel, Shriji N.; Tao, Yuankai K.

    2017-02-01

    Scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT) enable noninvasive in vivo diagnostic imaging and provide complementary en face and depth-resolved visualization of ophthalmic structures, respectively. We previously demonstrated concurrent multimodal swept-source spectrally encoded scanning laser ophthalmoscopy and OCT (SS-SESLO-OCT) at 1060 nm using a swept-source and double clad fiber coupler. Here, we present system enhancements and novel designs for a modular SS-SESLO-OCT scan-head that can be coupled to ophthalmic surgical microscope-integrated and slit-lamp imaging optics. Multimodal SS-SESLO-OCT was demonstrated using a custom-built swept-source OCT engine with a 200 kHz 1060 nm source that was optically buffered for concurrent SESLO and OCT imaging at 100% duty cycle and 400 kHz sweep-rate. A shared optical relay and fast-axis galvanometer ensured inherent co-registration between SESLO and OCT field-of-views and concurrent acquisition of an en face SESLO image with each OCT cross-section. SESLO and OCT frames were acquired at 200 fps with 2560 x 2000 pix. (spectral x lateral). We show in vivo human ophthalmic imaging data using surgical microscope-integrated and slit-lamp imaging relays to demonstrate the utility of our SS-SESLO-OCT design. Our self-contained modular scan-head can be used for either intraoperative guidance or clinical diagnostics and reduces the complexity, cost, and maintenance required for clinical translation of these technologies. We believe concurrent multimodal SS-SESLO-OCT may benefit 1) intraoperative imaging by allowing for real-time surgical feedback, instrument tracking, and overlays of computationally extracted image-based surrogate biomarkers of disease, and 2) slit-lamp imaging by enabling aiming, image registration, and multi-field mosaicking.

  17. Exploration of fluorescent protein voltage probes based on circularly permuted fluorescent proteins

    Directory of Open Access Journals (Sweden)

    Sunita G Gautam

    2009-10-01

    Full Text Available Genetically-encoded fluorescent protein voltage sensors are promising tools for optical monitoring of the electrical activity of cells. Over the last decade, several designs of fusion proteins have been explored and some of them have proven to be sensitive enough to record membrane voltage transients from single mammalian cells. Most prominent are the families of VSFPs (Voltage Sensitive Fluorescent Proteins that utilize the voltage sensor domain of Ci-VSP (Ciona Intestinalis voltage sensor-containing phosphatase. The voltage sensitivity of the fluorescence readout of these previously reported membrane potential indicators is achieved either via a change in the efficiency of fluorescence resonance energy transfer (FRET between two fluorescent protein (FP spectral variants or via modulation in the fluorescence intensity of a single FP. Here, we report our exploration on a third VSFP design principle based on circularly-permuted fluorescent protein (cpFP variants. Using circularly-permuted EGFP derived from GCaMP2 and two newly generated circularly-permuted variants of the far-red emitting protein named mKate, we generated and characterized a series of voltage-sensitive probes wherein the cpFPs were fused to the voltage sensor domain of Ci-VSP. The most promising variants were based on circularly permuted mKate with new N- and C-termini given by residues 180 and 182. Even so their voltage sensitivity was relatively modest, they constitute a proof of principle for this novel protein design.

  18. Optical recording of neuronal activity with a genetically-encoded calcium indicator in anesthetized and freely moving mice

    Directory of Open Access Journals (Sweden)

    Henry Lütcke

    2010-04-01

    Full Text Available Fluorescent calcium (Ca2+ indicator proteins (FCIPs are promising tools for functional imaging of cellular activity in living animals. However, they have still not reached their full potential for in vivo imaging of neuronal activity due to limitations in expression levels, dynamic range, and sensitivity for reporting action potentials. Here, we report that viral expression of the ratiometric Ca2+ sensor yellow cameleon 3.60 (YC3.60 in pyramidal neurons of mouse barrel cortex enables in vivo measurement of neuronal activity with high dynamic range and sensitivity across multiple spatial scales. By combining juxtacellular recordings and two-photon imaging in vitro and in vivo, we demonstrate that YC3.60 can resolve single action potential (AP-evoked Ca2+ transients and reliably reports bursts of APs with negligible saturation. Spontaneous and whisker-evoked Ca2+ transients were detected in individual apical dendrites and somata as well as in local neuronal populations. Moreover, bulk measurements using wide-field imaging or fiber-optics revealed sensory-evoked YC3.60 signals in large areas of the barrel field. Fiber-optic recordings in particular enabled measurements in awake, freely moving mice and revealed complex Ca2+ dynamics, possibly reflecting different behavior-related brain states. Viral expression of YC3.60 - in combination with various optical techniques - thus opens a multitude of opportunities for functional studies of the neural basis of animal behavior, from dendrites to the levels of local and large-scale neuronal populations.

  19. High Voltage Ramp Generator for Electro-Optically Tunable Filter for the MSE-CIF Diagnostics on NSTX.

    Science.gov (United States)

    Wu, Ying; Levinton, Fred

    2004-11-01

    The motional Stark effect (MSE) diagnostic is routinely used to determine the q-profile in large fusion devices. To apply the MSE diagnostic to experiments with low magnetic fields such as NSTX (<1 T), a tunable birefringent Lyot filter is used with high throughput and high resolution which allows for a good signal-to-noise ratio. The birefringent filter is made from lithium-niobate crystals, which are coated with a layer of indium tin-oxide (ITO). The ITO layer is a transparent conductive coating. By applying an electric field across the crystal the index of refraction is varied. This allows tunability of the filter. Putting multiple crystals together and tuning them individually it is possible to pass certain wavelengths of light and reject others. A high voltage ramp generator circuit is under development to ramp a 5 kV signal using a simple design involving MOSFET ladders. The goal is to design the circuit so that it can ramp ±5000 volts at a frequency of around 1 kHz. This would allow the filter to sweep over a range of ˜ 1nm.

  20. Stimulus encoding within the barn owl optic tectum using gamma oscillations vs. spike rate: a modeling approach.

    Science.gov (United States)

    Patel, Mainak; Reed, Mike

    2013-01-01

    The optic tectum of the barn owl is a multimodal structure with multiple layers, with each layer topographically organized according to spatial receptive field. The response of a site to a stimulus can be measured as either spike rate or local field potential (LFP) gamma (25-90 Hz) power; within superficial layers, spike rate and gamma power spatial tuning curves are narrow and contrast-response functions rise slowly. Within deeper layers, however, spike rate tuning curves broaden and gamma power contrast-response functions sharpen. In this work, we employ a computational model to describe the inputs required to generate these transformations from superficial to deep layers and show that gamma power and spike rate can act as parallel information processing streams.

  1. Monitoring activity in neural circuits with genetically encoded indicators

    Directory of Open Access Journals (Sweden)

    Gerard Joseph Broussard

    2014-12-01

    Full Text Available Recent developments in genetically encoded indicators of neural activity (GINAs have greatly advanced the field of systems neuroscience. As they are encoded by DNA, GINAs can be targeted to genetically defined cellular populations. Combined with fluorescence microscopy, most notably multi-photon imaging, GINAs allow chronic simultaneous optical recordings from large populations of neurons or glial cells in awake, behaving mammals, particularly rodents. This large-scale recording of neural activity at multiple temporal and spatial scales has greatly advanced our understanding of the dynamics of neural circuitry underlying behavior—a critical first step toward understanding the complexities of brain function, such as sensorimotor integration and learning.Here, we summarize the recent development and applications of the major classes of GINAs. In particular, we take an in-depth look at the design of available GINA families with a particular focus on genetically encoded calcium indicators, sensors probing synaptic activity, and genetically encoded voltage indicators. Using the family of the genetically encoded calcium indicator GCaMP as an example, we review established sensor optimization pipelines. We also discuss practical considerations for end users of GINAs about experimental methods including approaches for gene delivery, imaging system requirements, and data analysis techniques. With the growing toolbox of GINAs and with new microscopy techniques pushing beyond their current limits, the age of light can finally achieve the goal of broad and dense sampling of neuronal activity across time and brain structures to obtain a dynamic picture of brain function.

  2. Voltage Controlled Perpendicular Magnetic Anisotropy.

    Science.gov (United States)

    Noviasky, Nicholas; Sabirianov, Ildar; Cao, Shi; Zhang, Xiaozhe; Sokolov, Andrei; Kirianov, Eugene; Dowben, Peter; Ilie, Carolina C.; University of Nebraska at Lincoln Team; State University of New York at Oswego Collaboration

    Here we report the voltage controlled perpendicular magnetic anisotropy of a multilayer stack composed of P-type silicon substrate/ Gd2O3/ Co/ Pt grown by pulsed laser deposition (PLD) under ultra-high vacuum conditions. For examination of the voltage effect on magnetic properties of the samples, we performed magneto optical Kerr effect (MOKE) measurements. The results show a clear inverse relationship between voltage and coercivity. The exchange of oxygen ions which occurs at the interface between gadolinium oxide and cobalt may increase the cobalt oxide concentration within the optical interface layer. One potential application for this research could be the creation of a voltage controlled magnetic tunneling junction memory storage device. Proper implementation may be able to combine non-volatility with higher areal densities and low power consumption. NSF Research Experience for Faculty and Students at Undergraduate Institutions Program, UNL- MRSEC.

  3. Reduction of electro-optic half-wave voltage of 0.93Pb(Zn1/3Nb2/3)O3-0.07PbTiO3 single crystal through large piezoelectric strain

    Science.gov (United States)

    Sun, Enwei; Wang, Zhu; Zhang, Rui; Cao, Wenwu

    2011-01-01

    The influence of converse piezoelectric effect on the electro-optic coefficient of single domain relaxor-based 0.93Pb(Zn1/3Nb2/3)O3-0.07PbTiO3 (PZN-0.07PT) has been quantified under ambient conditions. It was found that the large piezoelectric constants d31 and d33 have significant influence to the half-wave voltage of electro-optic modulators. For single domain PZN-0.07PT crystal, Vπ13T is reduced by a factor of 8 and Vπ13L can be decreased by more than an order of magnitude due to the large piezoelectric effect. Compared to commonly used electro-optic crystal LiNbO3 and BaTiO3, PZN-xPT single crystal is much superior for optic phase modulation applications because they have much higher linear electro-optic coefficients and much lower half-wave voltage when piezoelectric strain influence is considered. PMID:21308004

  4. Reduction of electro-optic half-wave voltage of 0.93Pb(Zn(1/3)Nb(2/3))O(3)-0.07PbTiO(3) single crystal through large piezoelectric strain.

    Science.gov (United States)

    Sun, Enwei; Wang, Zhu; Zhang, Rui; Cao, Wenwu

    2011-01-01

    The influence of converse piezoelectric effect on the electro-optic coefficient of single domain relaxor-based 0.93Pb(Zn(1/3)Nb(2/3))O(3)-0.07PbTiO(3) (PZN-0.07PT) has been quantified under ambient conditions. It was found that the large piezoelectric constants d(31) and d(33) have significant influence to the half-wave voltage of electro-optic modulators. For single domain PZN-0.07PT crystal, Vπ13T is reduced by a factor of 8 and Vπ13L can be decreased by more than an order of magnitude due to the large piezoelectric effect. Compared to commonly used electro-optic crystal LiNbO(3) and BaTiO(3), PZN-xPT single crystal is much superior for optic phase modulation applications because they have much higher linear electro-optic coefficients and much lower half-wave voltage when piezoelectric strain influence is considered.

  5. Image-guided feedback for ophthalmic microsurgery using multimodal intraoperative swept-source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography

    Science.gov (United States)

    Li, Jianwei D.; Malone, Joseph D.; El-Haddad, Mohamed T.; Arquitola, Amber M.; Joos, Karen M.; Patel, Shriji N.; Tao, Yuankai K.

    2017-02-01

    Surgical interventions for ocular diseases involve manipulations of semi-transparent structures in the eye, but limited visualization of these tissue layers remains a critical barrier to developing novel surgical techniques and improving clinical outcomes. We addressed limitations in image-guided ophthalmic microsurgery by using microscope-integrated multimodal intraoperative swept-source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography (iSS-SESLO-OCT). We previously demonstrated in vivo human ophthalmic imaging using SS-SESLO-OCT, which enabled simultaneous acquisition of en face SESLO images with every OCT cross-section. Here, we integrated our new 400 kHz iSS-SESLO-OCT, which used a buffered Axsun 1060 nm swept-source, with a surgical microscope and TrueVision stereoscopic viewing system to provide image-based feedback. In vivo human imaging performance was demonstrated on a healthy volunteer, and simulated surgical maneuvers were performed in ex vivo porcine eyes. Denselysampled static volumes and volumes subsampled at 10 volumes-per-second were used to visualize tissue deformations and surgical dynamics during corneal sweeps, compressions, and dissections, and retinal sweeps, compressions, and elevations. En face SESLO images enabled orientation and co-registration with the widefield surgical microscope view while OCT imaging enabled depth-resolved visualization of surgical instrument positions relative to anatomic structures-of-interest. TrueVision heads-up display allowed for side-by-side viewing of the surgical field with SESLO and OCT previews for real-time feedback, and we demonstrated novel integrated segmentation overlays for augmented-reality surgical guidance. Integration of these complementary imaging modalities may benefit surgical outcomes by enabling real-time intraoperative visualization of surgical plans, instrument positions, tissue deformations, and image-based surrogate biomarkers correlated with completion of

  6. Feedback-induced voltage change of a Vertical-Cavity Surface-Emitting Laser as an active detection system for miniature optical scanning probe microscopes

    National Research Council Canada - National Science Library

    Dominique Heinis; Christophe Gorecki; Sylwester Bargiel; Bernard Cretin

    2006-01-01

    ... when we modulate mechanically the length of a coupled-cavity generating the feedback conditions. The voltage change of the VCSEL is produced by light back reflected from the sample to the laser cavity...

  7. Implementations of quantum and classical gates with linear optical devices and photon number quantum non-demolition measurement for polarization encoded qubits

    Energy Technology Data Exchange (ETDEWEB)

    Rosa Silva, Joao Batista [Department of Teleinformatic Engineering, Federal University of Ceara, Campus do Pici, 710, C.P. 6007, 60755-640 Fortaleza-Ceara (Brazil)]. E-mail: joaobrs@deti.ufc.br; Ramos, Rubens Viana [Department of Teleinformatic Engineering, Federal University of Ceara, Campus do Pici, 710, C.P. 6007, 60755-640 Fortaleza-Ceara (Brazil)]. E-mail: rubens@deti.ufc.br

    2006-12-11

    Aiming the construction of quantum computers and quantum communication systems based on optical devices, in this work we present possible implementations of quantum and classical CNOTs gates, as well an optical setup for generation and distribution of bipartite entangled states, using linear optical devices and photon number quantum non-demolition measurement.

  8. Real-time demonstration of 128-QAM-encoded optical OFDM transmission with a 5.25bit/s/Hz spectral efficiency in simple IMDD systems utilizing directly modulated DFB lasers.

    Science.gov (United States)

    Jin, X Q; Giddings, R P; Hugues-Salas, E; Tang, J M

    2009-10-26

    The feasibility of implementing 128-QAM in off-the-shelf component-based real-time optical OFDM (OOFDM) transceivers incorporating advanced channel estimation, on-line performance monitoring and live parameter optimisation, is experimentally investigated, for the first time, in intensity-modulation and direct-detection (IMDD) single-mode fibre (SMF) and multi-mode fibre (MMF) transmission systems involving directly modulated DFB lasers. The highest ever spectral efficiency of 5.25bit/s/Hz is demonstrated successfully in the aforementioned simple systems. Experimental investigations show that, it is feasible to transmit 5.25 Gb/s 128-QAM-encoded OOFDM real-time signals over 25 km MetroCor(TM) SMFs and 500 m 62.5/125 microm OM1 MMFs. The impact of key parameters on the transmission performance of the real-time OOFDM transceivers with 128-QAM encoding are explored, based on which optimum signal clipping ratios are identified.

  9. Electro-optic control of a PPLN-unpoled LiNbO3 boundary for low-voltage Q switching of an intracavity frequency-doubled Nd3+:YVO4 laser.

    Science.gov (United States)

    Torregrosa, A J; Maestre, H; Fernández-Pousa, C R; Pereda, J A; Capmany, J

    2009-08-01

    We present a simple technique to integrate an electro-optic Q switch in a periodically poled bulk lithium niobate crystal bounded by two unpoled (monodomain) regions. The technique exploits the high sensitivity to low applied electric fields of the total internal reflection condition in the periodic poled-unpoled boundary for the small grazing incidence angles associated with the diffraction of a focused Gaussian beam that propagates in the periodically poled region with its axis parallel to the boundary. When the arrangement is placed intracavity to a 1064 nm diode-pumped Nd(3+):YVO(4) laser, it performs simultaneously as a Q switch and as a second-harmonic generator, with Q switching starting at applied voltages as low as 1 V over a 500 microm thickness and with no additional optical elements.

  10. Optics

    CERN Document Server

    Mathieu, Jean Paul

    1975-01-01

    Optics, Parts 1 and 2 covers electromagnetic optics and quantum optics. The first part of the book examines the various of the important properties common to all electromagnetic radiation. This part also studies electromagnetic waves; electromagnetic optics of transparent isotropic and anisotropic media; diffraction; and two-wave and multi-wave interference. The polarization states of light, the velocity of light, and the special theory of relativity are also examined in this part. The second part is devoted to quantum optics, specifically discussing the classical molecular theory of optical p

  11. Enhanced optical power and low forward voltage of GaN-based light-emitting diodes with Ga-doped ZnO transparent conducting layer

    Science.gov (United States)

    Park, Tae-Young; Choi, Yong-Seok; Kang, Jang-Won; Jeong, Jae-Ho; Park, Seong-Ju; Jeon, Dong Min; Kim, Je Won; Kim, Yong Chun

    2010-02-01

    Ga-doped ZnO (ZnO:Ga) films were grown by metalorganic chemical vapor deposition as transparent conducting layers for GaN light-emitting diodes (LEDs). The forward voltage of LEDs with ZnO:Ga was 3.3 V at 20 mA. The low forward voltage was attributed to the removal of a resistive ZnGa2O4 phase, decreased resistivity of ZnO:Ga films, and increased hole concentration in p-GaN by thermal annealing process. The light output power of LEDs with ZnO:Ga was increased by 25% at 20 mA compared to that of LEDs with Sn-doped indium oxide due to the enhanced transmittance and the increased hole concentration in p-GaN.

  12. Voltage Control of Magnetic Anisotropy

    Science.gov (United States)

    Hao, Guanhua; Cao, Shi; Noviasky, Nick; Ilie, Carolina; Sokolov, Andre; Yin, Yuewei; Xu, Xiaoshan; Dowben, Peter

    Pd/Co/Gd2O3/Si heterostructures were fabricated via pulsed laser deposition and e-beam evaporation. Hysteresis loops, obtained by longitudinal magneto-optical Kerr-effect (MOKE) measurements, indicates an initial in-plane magnetic anisotropy. Applying a perpendicular voltage on the sample, the differences between the polar and longitudinal MOKE and anomalous Hall effect data indicates there is a reversible change in magnetic anisotropy, from in-plane to out-of-plane, with applied voltage. Prior work by others suggests that the change in magnetic anisotropy is due to redox reactions at the Co/Gd2O3 interference. Voltage controlled magnetism can result from changing interfacial chemistry and does not always require a magneto-electric coupling tensor.

  13. Optics

    CERN Document Server

    Fincham, W H A

    2013-01-01

    Optics: Ninth Edition Optics: Ninth Edition covers the work necessary for the specialization in such subjects as ophthalmic optics, optical instruments and lens design. The text includes topics such as the propagation and behavior of light; reflection and refraction - their laws and how different media affect them; lenses - thick and thin, cylindrical and subcylindrical; photometry; dispersion and color; interference; and polarization. Also included are topics such as diffraction and holography; the limitation of beams in optical systems and its effects; and lens systems. The book is recommen

  14. Universal dynamic goniometer for rotary encoders

    Science.gov (United States)

    Smirnov, Nikolai V.; Latyev, Svjatoslav M.; Naumova, Anastasiia I.

    2017-06-01

    A novel dynamic goniometer for the accuracy of rotary encoders has been developed on the base of the method of comparison with the reference encoder. The set-up of the goniometer considers all constructive and informative characteristics of measured encoders. The novel goniometer construction uses the new compensating method of instrumental errors in automatic working process. The advantages of the dynamic goniometer in combination with an optical rotary encoder at the reduction of the measuring time and a simultaneous increase of the accuracy.

  15. Optics

    CERN Document Server

    Fincham, W H A

    2013-01-01

    Optics: Eighth Edition covers the work necessary for the specialization in such subjects as ophthalmic optics, optical instruments and lens design. The text includes topics such as the propagation and behavior of light; reflection and refraction - their laws and how different media affect them; lenses - thick and thin, cylindrical and subcylindrical; photometry; dispersion and color; interference; and polarization. Also included are topics such as diffraction and holography; the limitation of beams in optical systems and its effects; and lens systems. The book is recommended for engineering st

  16. Holographically Encoded Volume Phase Masks

    Science.gov (United States)

    2015-07-13

    optics ,” Nat. Photonics 4, 188–193 (2010). 26. H. Kogelnik, “Coupled wave theory for thick volume holograms ,” Bell System Tech. J. 45(9), 2909–2944...phase masks Marc SeGall, Ivan Divliansky,* Clémence Jollivet, Axel Schülzgen, and Leonid B. Glebov University of Central Florida, College of Optics and...satisfying the Bragg condition of the hologram . Moreover, this approach enables the capability to encode and multiplex several phase masks into a single

  17. DVR(Dynamic Voltage Restorer)

    Indian Academy of Sciences (India)

    First page Back Continue Last page Graphics. DVR(Dynamic Voltage Restorer). Supply voltage Sag compensation. Supply voltage Swell Compensation. Balancing the Load voltage. Compensation of Supply Voltage Harmonics.

  18. Characterization of Sensitivity Encoded Silicon Photomultiplier (SeSP) with 1-Dimensional and 2-Dimensional Encoding for High Resolution PET/MR

    Science.gov (United States)

    Omidvari, Negar; Schulz, Volkmar

    2015-06-01

    This paper evaluates the performance of a new type of PET detectors called sensitivity encoded silicon photomultiplier (SeSP), which allows a direct coupling of small-pitch crystal arrays to the detector with a reduction in the number of readout channels. Four SeSP devices with two separate encoding schemes of 1D and 2D were investigated in this study. Furthermore, both encoding schemes were manufactured in two different sizes of 4 ×4 mm2 and 7. 73 ×7. 9 mm2, in order to investigate the effect of size on detector parameters. All devices were coupled to LYSO crystal arrays with 1 mm pitch size and 10 mm height, with optical isolation between crystals. The characterization was done for the key parameters of crystal-identification, energy resolution, and time resolution as a function of triggering threshold and over-voltage (OV). Position information was archived using the center of gravity (CoG) algorithm and a least squares approach (LSQA) in combination with a mean light matrix around the photo-peak. The positioning results proved the capability of all four SeSP devices in precisely identifying all crystals coupled to the sensors. Energy resolution was measured at different bias voltages, varying from 12% to 18% (FWHM) and paired coincidence time resolution (pCTR) of 384 ps to 1.1 ns was obtained for different SeSP devices at about 18 °C room temperature. However, the best time resolution was achieved at the highest over-voltage, resulting in a noise ratio of 99.08%.

  19. Mutations in PRPS1, which encodes the phosphoribosyl pyrophosphate synthetase enzyme critical for nucleotide biosynthesis, cause hereditary peripheral neuropathy with hearing loss and optic neuropathy (cmtx5).

    Science.gov (United States)

    Kim, Hee-Jin; Sohn, Kwang-Min; Shy, Michael E; Krajewski, Karen M; Hwang, Miok; Park, June-Hee; Jang, Sue-Yon; Won, Hong-Hee; Choi, Byung-Ok; Hong, Sung Hwa; Kim, Byoung-Joon; Suh, Yeon-Lim; Ki, Chang-Seok; Lee, Soo-Youn; Kim, Sun-Hee; Kim, Jong-Won

    2007-09-01

    We have identified missense mutations at conserved amino acids in the PRPS1 gene on Xq22.3 in two families with a syndromic form of inherited peripheral neuropathy, one of Asian and one of European descent. The disease is inherited in an X-linked recessive manner, and the affected male patients invariably develop sensorineural hearing loss of prelingual type followed by gating disturbance and visual loss. The family of European descent was reported in 1967 as having Rosenberg-Chutorian syndrome, and recently a Korean family with the same symptom triad was identified with a novel disease locus CMTX5 on the chromosome band Xq21.32-q24. PRPS1 (phosphoribosyl pyrophosphate synthetase 1) is an isoform of the PRPS gene family and is ubiquitously expressed in human tissues, including cochlea. The enzyme mediates the biochemical step critical for purine metabolism and nucleotide biosynthesis. The mutations identified were E43D, in patients with Rosenberg-Chutorian syndrome, and M115T, in the Korean patients with CMTX5. We also showed decreased enzyme activity in patients with M115T. PRPS1 is the first CMT gene that encodes a metabolic enzyme, shedding a new light on the understanding of peripheral nerve-specific metabolism and also suggesting the potential of PRPS1 as a target for drugs in prevention and treatment of peripheral neuropathy by antimetabolite therapy.

  20. Optical imaging: bacteria, viruses, and mammalian cells encoding light-emitting proteins reveal the locations of primary tumors and metastases in animals.

    Science.gov (United States)

    Yu, Yong A; Timiryasova, Tatyana; Zhang, Qian; Beltz, Richard; Szalay, Aladar A

    2003-11-01

    Early detection of tumors and their metastases is crucial for the prognosis of cancer treatment. Traditionally, tumor detection is achieved by various methods, including magnetic resonance imaging and computerized tomography. With the recent cloning, cellular expression, and real-time imaging of light-emitting proteins, such as Renilla luciferase (Ruc), bacterial luciferase (Lux), firefly luciferase (Luc), green fluorescent protein (GFP), or Ruc-GFP fusion protein, significant efforts have been focused on using these marker proteins for tumor detection. It has also been demonstrated that certain bacteria, viruses, and mammalian cells (BVMC), when administered systemically, are able to gain entry and replicate selectively in tumors. In addition, many tissue/tumor specific promoters have been cloned which allow transgene expression specifically in tumor tissues. Therefore, when light-emitting protein encoded BVMC are injected systemically into rodents, tumor-specific marker gene expression is achieved and is detected in real time based on light emission. Consequently, the locations of primary tumors and previously unknown metastases in animals are revealed in vivo. In the future it will likely be feasible to use engineered light-emitting BVMC as probes for tumor detection and as gene-delivery vehicles in vivo for cancer therapy.

  1. Technological Aspects: High Voltage

    CERN Document Server

    Faircloth, D.C.

    2013-12-16

    This paper covers the theory and technological aspects of high-voltage design for ion sources. Electric field strengths are critical to understanding high-voltage breakdown. The equations governing electric fields and the techniques to solve them are discussed. The fundamental physics of high-voltage breakdown and electrical discharges are outlined. Different types of electrical discharges are catalogued and their behaviour in environments ranging from air to vacuum are detailed. The importance of surfaces is discussed. The principles of designing electrodes and insulators are introduced. The use of high-voltage platforms and their relation to system design are discussed. The use of commercially available high-voltage technology such as connectors, feedthroughs and cables are considered. Different power supply technologies and their procurement are briefly outlined. High-voltage safety, electric shocks and system design rules are covered.

  2. Experimental investigation of SDBD plasma actuator driven by AC high voltage with a superimposed positive pulse bias voltage

    Science.gov (United States)

    Qi, Xiao-Hua; Yan, Hui-Jie; Yang, Liang; Hua, Yue; Ren, Chun-Sheng

    2017-08-01

    In this work, a driven voltage consisting of AC high voltage with a superimposed positive pulse bias voltage ("AC+ Positive pulse bias" voltage) is adopted to study the performance of a surface dielectric barrier discharge plasma actuator under atmospheric conditions. To compare the performance of the actuator driven by single-AC voltage and "AC+ Positive pulse bias" voltage, the actuator-induced thrust force and power consumption are measured as a function of the applied AC voltage, and the measured results indicate that the thrust force can be promoted significantly after superimposing the positive pulse bias voltage. The physical mechanism behind the thrust force changes is analyzed by measuring the optical properties, electrical characteristics, and surface potential distribution. Experimental results indicate that the glow-like discharge in the AC voltage half-cycle, next to the cycle where a bias voltage pulse has been applied, is enhanced after applying the positive pulse bias voltage, and this perhaps is the main reason for the thrust force increase. Moreover, surface potential measurement results reveal that the spatial electric field formed by the surface charge accumulation after positive pulse discharge can significantly affect the applied external electric field, and this perhaps can be responsible for the experimental phenomenon that the decrease of thrust force is delayed by pulse bias voltage action after the filament discharge occurs in the glow-like discharge region. The schlieren images further verify that the actuator-induced airflow velocity increases with the positive pulse voltage.

  3. High voltage test techniques

    CERN Document Server

    Kind, Dieter

    2001-01-01

    The second edition of High Voltage Test Techniques has been completely revised. The present revision takes into account the latest international developments in High Voltage and Measurement technology, making it an essential reference for engineers in the testing field.High Voltage Technology belongs to the traditional area of Electrical Engineering. However, this is not to say that the area has stood still. New insulating materials, computing methods and voltage levels repeatedly pose new problems or open up methods of solution; electromagnetic compatibility (EMC) or components and systems al

  4. High voltage engineering

    CERN Document Server

    Rizk, Farouk AM

    2014-01-01

    Inspired by a new revival of worldwide interest in extra-high-voltage (EHV) and ultra-high-voltage (UHV) transmission, High Voltage Engineering merges the latest research with the extensive experience of the best in the field to deliver a comprehensive treatment of electrical insulation systems for the next generation of utility engineers and electric power professionals. The book offers extensive coverage of the physical basis of high-voltage engineering, from insulation stress and strength to lightning attachment and protection and beyond. Presenting information critical to the design, selec

  5. Stray voltage mitigation

    Energy Technology Data Exchange (ETDEWEB)

    Jamali, B.; Piercy, R.; Dick, P. [Kinetrics Inc., Toronto, ON (Canada). Transmission and Distribution Technologies

    2008-04-09

    This report discussed issues related to farm stray voltage and evaluated mitigation strategies and costs for limiting voltage to farms. A 3-phase, 3-wire system with no neutral ground was used throughout North America before the 1930s. Transformers were connected phase to phase without any electrical connection between the primary and secondary sides of the transformers. Distribution voltage levels were then increased and multi-grounded neutral wires were added. The earth now forms a parallel return path for the neutral current that allows part of the neutral current to flow continuously through the earth. The arrangement is responsible for causing stray voltage. Stray voltage causes uneven milk production, increased incidences of mastitis, and can create a reluctance to drink water amongst cows when stray voltages are present. Off-farm sources of stray voltage include phase unbalances, undersized neutral wire, and high resistance splices on the neutral wire. Mitigation strategies for reducing stray voltage include phase balancing; conversion from single to 3-phase; increasing distribution voltage levels, and changing pole configurations. 22 refs., 5 tabs., 13 figs.

  6. Voltage verification unit

    Science.gov (United States)

    Martin, Edward J [Virginia Beach, VA

    2008-01-15

    A voltage verification unit and method for determining the absence of potentially dangerous potentials within a power supply enclosure without Mode 2 work is disclosed. With this device and method, a qualified worker, following a relatively simple protocol that involves a function test (hot, cold, hot) of the voltage verification unit before Lock Out/Tag Out and, and once the Lock Out/Tag Out is completed, testing or "trying" by simply reading a display on the voltage verification unit can be accomplished without exposure of the operator to the interior of the voltage supply enclosure. According to a preferred embodiment, the voltage verification unit includes test leads to allow diagnostics with other meters, without the necessity of accessing potentially dangerous bus bars or the like.

  7. Fuel Cell/Electrochemical Cell Voltage Monitor

    Science.gov (United States)

    Vasquez, Arturo

    2012-01-01

    A concept has been developed for a new fuel cell individual-cell-voltage monitor that can be directly connected to a multi-cell fuel cell stack for direct substack power provisioning. It can also provide voltage isolation for applications in high-voltage fuel cell stacks. The technology consists of basic modules, each with an 8- to 16-cell input electrical measurement connection port. For each basic module, a power input connection would be provided for direct connection to a sub-stack of fuel cells in series within the larger stack. This power connection would allow for module power to be available in the range of 9-15 volts DC. The relatively low voltage differences that the module would encounter from the input electrical measurement connection port, coupled with the fact that the module's operating power is supplied by the same substack voltage input (and so will be at similar voltage), provides for elimination of high-commonmode voltage issues within each module. Within each module, there would be options for analog-to-digital conversion and data transfer schemes. Each module would also include a data-output/communication port. Each of these ports would be required to be either non-electrical (e.g., optically isolated) or electrically isolated. This is necessary to account for the fact that the plurality of modules attached to the stack will normally be at a range of voltages approaching the full range of the fuel cell stack operating voltages. A communications/ data bus could interface with the several basic modules. Options have been identified for command inputs from the spacecraft vehicle controller, and for output-status/data feeds to the vehicle.

  8. Sol-Gel Material-Enabled Electro-Optic Polymer Modulators

    Directory of Open Access Journals (Sweden)

    Roland Himmelhuber

    2015-07-01

    Full Text Available Sol-gels are an important material class, as they provide easy modification of material properties, good processability and are easy to synthesize. In general, an electro-optic (EO modulator transforms an electrical signal into an optical signal. The incoming electrical signal is most commonly information encoded in a voltage change. This voltage change is then transformed into either a phase change or an intensity change in the light signal. The less voltage needed to drive the modulator and the lower the optical loss, the higher the link gain and, therefore, the better the performance of the modulator. In this review, we will show how sol-gels can be used to enhance the performance of electro-optic modulators by allowing for designs with low optical loss, increased poling efficiency and manipulation of the electric field used for driving the modulator. The optical loss is influenced by the propagation loss in the device, as well as the losses occurring during fiber coupling in and out of the device. In both cases, the use of sol-gel materials can be beneficial due to the wide range of available refractive indices and low optical attenuation. The influence of material properties and synthesis conditions on the device performance will be discussed.

  9. Sol-Gel Material-Enabled Electro-Optic Polymer Modulators.

    Science.gov (United States)

    Himmelhuber, Roland; Norwood, Robert A; Enami, Yasufumi; Peyghambarian, Nasser

    2015-07-27

    Sol-gels are an important material class, as they provide easy modification of material properties, good processability and are easy to synthesize. In general, an electro-optic (EO) modulator transforms an electrical signal into an optical signal. The incoming electrical signal is most commonly information encoded in a voltage change. This voltage change is then transformed into either a phase change or an intensity change in the light signal. The less voltage needed to drive the modulator and the lower the optical loss, the higher the link gain and, therefore, the better the performance of the modulator. In this review, we will show how sol-gels can be used to enhance the performance of electro-optic modulators by allowing for designs with low optical loss, increased poling efficiency and manipulation of the electric field used for driving the modulator. The optical loss is influenced by the propagation loss in the device, as well as the losses occurring during fiber coupling in and out of the device. In both cases, the use of sol-gel materials can be beneficial due to the wide range of available refractive indices and low optical attenuation. The influence of material properties and synthesis conditions on the device performance will be discussed.

  10. Excitability Constraints on Voltage-Gated Sodium Channels

    OpenAIRE

    Brenner, Michael; Angelino, Elaine

    2007-01-01

    We study how functional constraints bound and shape evolution through an analysis of mammalian voltage-gated sodium channels. The primary function of sodium channels is to allow the propagation of action potentials. Since Hodgkin and Huxley, mathematical models have suggested that sodium channel properties need to be tightly constrained for an action potential to propagate. There are nine mammalian genes encoding voltage-gated sodium channels, many of which are more than approximately 90% ide...

  11. Models of optical quantum computing

    Directory of Open Access Journals (Sweden)

    Krovi Hari

    2017-03-01

    Full Text Available I review some work on models of quantum computing, optical implementations of these models, as well as the associated computational power. In particular, we discuss the circuit model and cluster state implementations using quantum optics with various encodings such as dual rail encoding, Gottesman-Kitaev-Preskill encoding, and coherent state encoding. Then we discuss intermediate models of optical computing such as boson sampling and its variants. Finally, we review some recent work in optical implementations of adiabatic quantum computing and analog optical computing. We also provide a brief description of the relevant aspects from complexity theory needed to understand the results surveyed.

  12. Calibration of Voltage Transformers and High- Voltage Capacitors at NIST

    Science.gov (United States)

    Anderson, William E.

    1989-01-01

    The National Institute of Standards and Technology (NIST) calibration service for voltage transformers and high-voltage capacitors is described. The service for voltage transformers provides measurements of ratio correction factors and phase angles at primary voltages up to 170 kV and secondary voltages as low as 10 V at 60 Hz. Calibrations at frequencies from 50–400 Hz are available over a more limited voltage range. The service for high-voltage capacitors provides measurements of capacitance and dissipation factor at applied voltages ranging from 100 V to 170 kV at 60 Hz depending on the nominal capacitance. Calibrations over a reduced voltage range at other frequencies are also available. As in the case with voltage transformers, these voltage constraints are determined by the facilities at NIST. PMID:28053409

  13. High voltage engineering fundamentals

    CERN Document Server

    Kuffel, E; Hammond, P

    1984-01-01

    Provides a comprehensive treatment of high voltage engineering fundamentals at the introductory and intermediate levels. It covers: techniques used for generation and measurement of high direct, alternating and surge voltages for general application in industrial testing and selected special examples found in basic research; analytical and numerical calculation of electrostatic fields in simple practical insulation system; basic ionisation and decay processes in gases and breakdown mechanisms of gaseous, liquid and solid dielectrics; partial discharges and modern discharge detectors; and over

  14. Device for monitoring cell voltage

    Science.gov (United States)

    Doepke, Matthias [Garbsen, DE; Eisermann, Henning [Edermissen, DE

    2012-08-21

    A device for monitoring a rechargeable battery having a number of electrically connected cells includes at least one current interruption switch for interrupting current flowing through at least one associated cell and a plurality of monitoring units for detecting cell voltage. Each monitoring unit is associated with a single cell and includes a reference voltage unit for producing a defined reference threshold voltage and a voltage comparison unit for comparing the reference threshold voltage with a partial cell voltage of the associated cell. The reference voltage unit is electrically supplied from the cell voltage of the associated cell. The voltage comparison unit is coupled to the at least one current interruption switch for interrupting the current of at least the current flowing through the associated cell, with a defined minimum difference between the reference threshold voltage and the partial cell voltage.

  15. Voltage-gated sodium channels: action players with many faces

    NARCIS (Netherlands)

    Koopmann, Tamara T.; Bezzina, Connie R.; Wilde, Arthur A. M.

    2006-01-01

    Voltage-gated sodium channels are responsible for the upstroke of the action potential and thereby play an important role in propagation of the electrical impulse in excitable tissues like muscle, nerve and the heart. Duplication of the sodium channels encoding genes during evolution generated the

  16. Mitigation of Voltage Sags in CIGRE Low Voltage Distribution Network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Mahat, Pukar

    2013-01-01

    problems in the distribution system. The voltage problems dealt with in this paper are to show how to mitigate voltage sags in the CIGRE Low Voltage (LV) test network and networks like this. The voltage sags, for the tested cases in the CIGRE LV test network are mainly due to three phase faults....... The compensation of voltage sags in the different parts of CIGRE distribution network is done by using the four STATCOM compensators already existing in the test grid. The simulations are carried out in DIgSILENT power factory software version 15.0.......Any problem in voltage in a power network is undesirable as it aggravates the quality of the power. Power electronic devices such as Voltage Source Converter (VSC) based Static Synchronous Compensator (STATCOM), Dynamic Voltage Restorer (DVR) etc. are commonly used for the mitigation of voltage...

  17. Voltage-gated calcium flux mediatesEscherichia colimechanosensation.

    Science.gov (United States)

    Bruni, Giancarlo N; Weekley, R Andrew; Dodd, Benjamin J T; Kralj, Joel M

    2017-08-29

    Electrically excitable cells harness voltage-coupled calcium influx to transmit intracellular signals, typically studied in neurons and cardiomyocytes. Despite intense study in higher organisms, investigations of voltage and calcium signaling in bacteria have lagged due to their small size and a lack of sensitive tools. Only recently were bacteria shown to modulate their membrane potential on the timescale of seconds, and little is known about the downstream effects from this modulation. In this paper, we report on the effects of electrophysiology in individual bacteria. A genetically encoded calcium sensor expressed in Escherichia coli revealed calcium transients in single cells. A fusion sensor that simultaneously reports voltage and calcium indicated that calcium influx is induced by voltage depolarizations, similar to metazoan action potentials. Cytoplasmic calcium levels and transients increased upon mechanical stimulation with a hydrogel, and single cells altered protein concentrations dependent on the mechanical environment. Blocking voltage and calcium flux altered mechanically induced changes in protein concentration, while inducing calcium flux reproduced these changes. Thus, voltage and calcium relay a bacterial sense of touch and alter cellular lifestyle. Although the calcium effectors remain unknown, these data open a host of new questions about E. coli , including the identity of the underlying molecular players, as well as other signals conveyed by voltage and calcium. These data also provide evidence that dynamic voltage and calcium exists as a signaling modality in the oldest domain of life, and therefore studying electrophysiology beyond canonical electrically excitable cells could yield exciting new findings.

  18. Encoding Microreactors with Droplet Chains in Microfluidics.

    Science.gov (United States)

    Song, Wenya; Lin, Gungun; Ge, Jin; Fassbender, Jürgen; Makarov, Denys

    2017-12-13

    Droplet-based high throughput biomolecular screening and combinatorial synthesis entail a viable indexing strategy to be developed for the identification of each microreactor. Here, we propose a novel indexing scheme based on the generation of droplet sequences on demand to form unique encoding droplet chains in fluidic networks. These codes are represented by multiunit and multilevel droplets packages, with each code unit possessing several distinct signal levels, potentially allowing large encoding capacity. For proof of concept, we use magnetic nanoparticles as the encoding material and a giant magnetoresistance (GMR) sensor-based active sorting system supplemented with an optical detector to generate and decode the sequence of one exemplar sample droplet reactor and a 4-unit quaternary magnetic code. The indexing capacity offered by 4-unit multilevel codes with this indexing strategy is estimated to exceed 104, which holds great promise for large-scale droplet-based screening and synthesis.

  19. Review of Random Phase Encoding in Volume Holographic Storage

    Directory of Open Access Journals (Sweden)

    Wei-Chia Su

    2012-09-01

    Full Text Available Random phase encoding is a unique technique for volume hologram which can be applied to various applications such as holographic multiplexing storage, image encryption, and optical sensing. In this review article, we first review and discuss diffraction selectivity of random phase encoding in volume holograms, which is the most important parameter related to multiplexing capacity of volume holographic storage. We then review an image encryption system based on random phase encoding. The alignment of phase key for decryption of the encoded image stored in holographic memory is analyzed and discussed. In the latter part of the review, an all-optical sensing system implemented by random phase encoding and holographic interconnection is presented.

  20. Mitigation of Unbalanced Voltage Sags and Voltage Unbalance in CIGRE Low Voltage Distribution Network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Mahat, Pukar

    2013-01-01

    . The voltage problems dealt with in this paper are to show how to mitigate unbalanced voltage sags and voltage unbalance in the CIGRE Low Voltage (LV) test network and net-works like this. The voltage unbalances, for the tested cases in the CIGRE LV test network are mainly due to single phase loads and due...... to unbalanced faults. The compensation of unbalanced voltage sags and voltage unbalance in the CIGRE distribution network is done by using the four STATCOM compensators already existing in the test grid. The simulations are carried out in DIgSILENT power factory software version 15.0.......Any problem with voltage in a power network is undesirable as it aggravates the quality of the power. Power electronic devices such as Voltage Source Converter (VSC) based Static Synchronous Compensator (STATCOM) etc. can be used to mitigate the voltage problems in the distribution system...

  1. Geomagnetism and Induced Voltage

    Science.gov (United States)

    Abdul-Razzaq, W.; Biller, R. D.

    2010-01-01

    Introductory physics laboratories have seen an influx of "conceptual integrated science" over time in their classrooms with elements of other sciences such as chemistry, biology, Earth science, and astronomy. We describe a laboratory to introduce this development, as it attracts attention to the voltage induced in the human brain as it…

  2. Method of implementing frequency-encoded NOT, OR and NOR ...

    Indian Academy of Sciences (India)

    Abstract. Optics has already proved its strong potentiality for the conduction of parallel logic, arithmetic and algebraic operations. In the last few decades several all-optical data processors were proposed. To implement these processors different data encoding/decoding techniques have been reported. In this context ...

  3. Simultaneous mapping of membrane voltage and calcium in zebrafish heart in vivo reveals chamber-specific developmental transitions in ionic currents

    Directory of Open Access Journals (Sweden)

    Jennifer H Hou

    2014-09-01

    Full Text Available The cardiac action potential (AP and the consequent cytosolic Ca2+ transient are key indicators of cardiac function. Natural developmental processes, as well as many drugs and pathologies change the waveform, propagation, or variability (between cells or over time of these parameters. Here we apply a genetically encoded dual-function calcium and voltage reporter (CaViar to study the development of the zebrafish heart in vivo between 1.5 and 4 days post fertilization (dpf. We developed a high-sensitivity spinning disk confocal microscope and associated software for simultaneous three-dimensional optical mapping of voltage and calcium. We produced a transgenic zebrafish line expressing CaViar under control of the heart-specific cmlc2 promoter, and applied ion channel blockers at a series of developmental stages to map the maturation of the action potential in vivo. Early in development, the AP initiated via a calcium current through L-type calcium channels. Between 90 – 102 hours post fertilization (hpf, the ventricular AP switched to a sodium-driven upswing, while the atrial AP remained calcium driven. In the adult zebrafish heart, a sodium current drives the AP in both the atrium and ventricle. Simultaneous voltage and calcium imaging with genetically encoded reporters provides a new approach for monitoring cardiac development, and the effects of drugs on cardiac function.

  4. Video time encoding machines.

    Science.gov (United States)

    Lazar, Aurel A; Pnevmatikakis, Eftychios A

    2011-03-01

    We investigate architectures for time encoding and time decoding of visual stimuli such as natural and synthetic video streams (movies, animation). The architecture for time encoding is akin to models of the early visual system. It consists of a bank of filters in cascade with single-input multi-output neural circuits. Neuron firing is based on either a threshold-and-fire or an integrate-and-fire spiking mechanism with feedback. We show that analog information is represented by the neural circuits as projections on a set of band-limited functions determined by the spike sequence. Under Nyquist-type and frame conditions, the encoded signal can be recovered from these projections with arbitrary precision. For the video time encoding machine architecture, we demonstrate that band-limited video streams of finite energy can be faithfully recovered from the spike trains and provide a stable algorithm for perfect recovery. The key condition for recovery calls for the number of neurons in the population to be above a threshold value.

  5. IDENTIFICATION OF ENCODED BEADS

    DEFF Research Database (Denmark)

    2005-01-01

    The present invention is relates to methods for the identification of spatially encoded beaded or granulated matrices comprising a plurality of immobilised particles. The identification is based on a distance matrix determination or based on a set of geometrical figures, such a triangles...

  6. Deployment of low-voltage regulator considering existing voltage control in medium-voltage distribution systems

    Directory of Open Access Journals (Sweden)

    Hiroshi Kikusato

    2016-01-01

    Full Text Available Many photovoltaic (PV systems have been installed in distribution systems. This installation complicates the maintenance of all voltages within the appropriate range in all low-voltage distribution systems (LVDSs because the trends in voltage fluctuation differ in each LVDS. The installation of a low-voltage regulator (LVR that can accordingly control the voltage in each LVDS has been studied as a solution to this problem. Voltage control in a medium-voltage distribution system must be considered to study the deployment of LVRs. In this study, we installed LVRs in the LVDSs in which the existing voltage-control scheme cannot prevent voltage deviation and performed a numerical simulation by using a distribution system model with PV to evaluate the deployment of the LVRs.

  7. High Voltage Charge Pump

    KAUST Repository

    Emira, Ahmed A.

    2014-10-09

    Various embodiments of a high voltage charge pump are described. One embodiment is a charge pump circuit that comprises a plurality of switching stages each including a clock input, a clock input inverse, a clock output, and a clock output inverse. The circuit further comprises a plurality of pumping capacitors, wherein one or more pumping capacitors are coupled to a corresponding switching stage. The circuit also comprises a maximum selection circuit coupled to a last switching stage among the plurality of switching stages, the maximum selection circuit configured to filter noise on the output clock and the output clock inverse of the last switching stage, the maximum selection circuit further configured to generate a DC output voltage based on the output clock and the output clock inverse of the last switching stage.

  8. Neural Semantic Encoders.

    Science.gov (United States)

    Munkhdalai, Tsendsuren; Yu, Hong

    2017-04-01

    We present a memory augmented neural network for natural language understanding: Neural Semantic Encoders. NSE is equipped with a novel memory update rule and has a variable sized encoding memory that evolves over time and maintains the understanding of input sequences through read, compose and write operations. NSE can also access multiple and shared memories. In this paper, we demonstrated the effectiveness and the flexibility of NSE on five different natural language tasks: natural language inference, question answering, sentence classification, document sentiment analysis and machine translation where NSE achieved state-of-the-art performance when evaluated on publically available benchmarks. For example, our shared-memory model showed an encouraging result on neural machine translation, improving an attention-based baseline by approximately 1.0 BLEU.

  9. High Voltage Seismic Generator

    Science.gov (United States)

    Bogacz, Adrian; Pala, Damian; Knafel, Marcin

    2015-04-01

    This contribution describes the preliminary result of annual cooperation of three student research groups from AGH UST in Krakow, Poland. The aim of this cooperation was to develop and construct a high voltage seismic wave generator. Constructed device uses a high-energy electrical discharge to generate seismic wave in ground. This type of device can be applied in several different methods of seismic measurement, but because of its limited power it is mainly dedicated for engineering geophysics. The source operates on a basic physical principles. The energy is stored in capacitor bank, which is charged by two stage low to high voltage converter. Stored energy is then released in very short time through high voltage thyristor in spark gap. The whole appliance is powered from li-ion battery and controlled by ATmega microcontroller. It is possible to construct larger and more powerful device. In this contribution the structure of device with technical specifications is resented. As a part of the investigation the prototype was built and series of experiments conducted. System parameter was measured, on this basis specification of elements for the final device were chosen. First stage of the project was successful. It was possible to efficiently generate seismic waves with constructed device. Then the field test was conducted. Spark gap wasplaced in shallowborehole(0.5 m) filled with salt water. Geophones were placed on the ground in straight line. The comparison of signal registered with hammer source and sparker source was made. The results of the test measurements are presented and discussed. Analysis of the collected data shows that characteristic of generated seismic signal is very promising, thus confirms possibility of practical application of the new high voltage generator. The biggest advantage of presented device after signal characteristics is its size which is 0.5 x 0.25 x 0.2 m and weight approximately 7 kg. This features with small li-ion battery makes

  10. Increased voltage photovoltaic cell

    Science.gov (United States)

    Ross, B.; Bickler, D. B.; Gallagher, B. D. (Inventor)

    1985-01-01

    A photovoltaic cell, such as a solar cell, is provided which has a higher output voltage than prior cells. The improved cell includes a substrate of doped silicon, a first layer of silicon disposed on the substrate and having opposite doping, and a second layer of silicon carbide disposed on the first layer. The silicon carbide preferably has the same type of doping as the first layer.

  11. Voltage imaging to understand connections and functions of neuronal circuits

    Science.gov (United States)

    Antic, Srdjan D.; Empson, Ruth M.

    2016-01-01

    Understanding of the cellular mechanisms underlying brain functions such as cognition and emotions requires monitoring of membrane voltage at the cellular, circuit, and system levels. Seminal voltage-sensitive dye and calcium-sensitive dye imaging studies have demonstrated parallel detection of electrical activity across populations of interconnected neurons in a variety of preparations. A game-changing advance made in recent years has been the conceptualization and development of optogenetic tools, including genetically encoded indicators of voltage (GEVIs) or calcium (GECIs) and genetically encoded light-gated ion channels (actuators, e.g., channelrhodopsin2). Compared with low-molecular-weight calcium and voltage indicators (dyes), the optogenetic imaging approaches are 1) cell type specific, 2) less invasive, 3) able to relate activity and anatomy, and 4) facilitate long-term recordings of individual cells' activities over weeks, thereby allowing direct monitoring of the emergence of learned behaviors and underlying circuit mechanisms. We highlight the potential of novel approaches based on GEVIs and compare those to calcium imaging approaches. We also discuss how novel approaches based on GEVIs (and GECIs) coupled with genetically encoded actuators will promote progress in our knowledge of brain circuits and systems. PMID:27075539

  12. Voltage Controlled Dynamic Demand Response

    DEFF Research Database (Denmark)

    Bhattarai, Bishnu Prasad; Bak-Jensen, Birgitte; Mahat, Pukar

    2013-01-01

    central or dispersed generations might not be sufficient for future scenario. One of the effective methods to cope with this scenario is to enable demand response. This paper proposes a dynamic voltage regulation based demand response technique to be applied in low voltage (LV) distribution feeders....... An adaptive dynamic model has been developed to determine composite voltage dependency of an aggregated load on feeder level. Following the demand dispatch or control signal, optimum voltage setting at the LV substation is determined based on the voltage dependency of the load. Furthermore, a new technique...... has been proposed to estimate the voltage at consumer point of connection (POC) to ensure operation within voltage limits. Finally, the effectiveness of the proposed method is analyzed comprehensively with reference to three different scenarios on a low voltage (LV) feeder (Borup feeder) owned...

  13. Low-voltage polyphasic circuits

    Science.gov (United States)

    Baird, William H.; Jaynes, Michael L.

    2010-05-01

    Experimentation with polyphasic voltages is greatly simplified when microcontrollers are used to generate multiple square waves with fixed phase offsets. Each square wave is sent through a simple second-order Sallen-Key filter to produce an approximately sinusoidal voltage signal. The microcontroller allows the reproduction of split-phase and three-phase voltage relationships, mirroring those commonly distributed on the North American power grid, at safe voltage levels.

  14. High voltage variable diameter insulator

    Science.gov (United States)

    Vanecek, David L.; Pike, Chester D.

    1984-01-01

    A high voltage feedthrough assembly (10) having a tubular insulator (15) extending between the ground plane ring (16) and the high voltage ring (30). The insulator (15) is made of Pyrex and decreases in diameter from the ground plane ring (16) to the high voltage ring (30), producing equipotential lines almost perpendicular to the wall (27) of the insulator (15) to optimize the voltage-holding capability of the feedthrough assembly (10).

  15. Charge-pump voltage converter

    Science.gov (United States)

    Brainard, John P [Albuquerque, NM; Christenson, Todd R [Albuquerque, NM

    2009-11-03

    A charge-pump voltage converter for converting a low voltage provided by a low-voltage source to a higher voltage. Charge is inductively generated on a transfer rotor electrode during its transit past an inductor stator electrode and subsequently transferred by the rotating rotor to a collector stator electrode for storage or use. Repetition of the charge transfer process leads to a build-up of voltage on a charge-receiving device. Connection of multiple charge-pump voltage converters in series can generate higher voltages, and connection of multiple charge-pump voltage converters in parallel can generate higher currents. Microelectromechanical (MEMS) embodiments of this invention provide a small and compact high-voltage (several hundred V) voltage source starting with a few-V initial voltage source. The microscale size of many embodiments of this invention make it ideally suited for MEMS- and other micro-applications where integration of the voltage or charge source in a small package is highly desirable.

  16. Transient voltage sharing in series-coupled high voltage switches

    Directory of Open Access Journals (Sweden)

    Editorial Office

    1992-07-01

    Full Text Available For switching voltages in excess of the maximum blocking voltage of a switching element (for example, thyristor, MOSFET or bipolar transistor such elements are often coupled in series - and additional circuitry has to be provided to ensure equal voltage sharing. Between each such series element and system ground there is a certain parasitic capacitance that may draw a significant current during high-speed voltage transients. The "open" switch is modelled as a ladder network. Analy­sis reveals an exponential progression in the distribution of the applied voltage across the elements. Overstressing thus oc­curs in some of the elements at levels of the total voltage that are significantly below the design value. This difficulty is overcome by grading the voltage sharing circuitry, coupled in parallel with each element, in a prescribed manner, as set out here.

  17. Coordinated Voltage Control of Distributed PV Inverters for Voltage Regulation in Low Voltage Distribution Networks

    DEFF Research Database (Denmark)

    Nainar, Karthikeyan; Pokhrel, Basanta Raj; Pillai, Jayakrishnan Radhakrishna

    2017-01-01

    This paper reviews and analyzes the existing voltage control methods of distributed solar PV inverters to improve the voltage regulation and thereby the hosting capacity of a low-voltage distribution network. A novel coordinated voltage control method is proposed based on voltage sensitivity...... optimization. The proposed method is used to calculate the voltage bands and droop settings of PV inverters at each node by the supervisory controller. The local controller of each PV inverter implements the volt/var control and if necessary, the active power curtailment as per the received settings and based...... on measured local voltages. The advantage of the proposed method is that the calculated reactive power and active power droop settings enable fair contribution of the PV inverters at each node to the voltage regulation. Simulation studies are conducted using DigSilent Power factory software on a simplified...

  18. Encoding and decoding of digital spiral imaging based on bidirectional transformation of light's spatial eigenmodes.

    Science.gov (United States)

    Zhang, Wuhong; Chen, Lixiang

    2016-06-15

    Digital spiral imaging has been demonstrated as an effective optical tool to encode optical information and retrieve topographic information of an object. Here we develop a conceptually new and concise scheme for optical image encoding and decoding toward free-space digital spiral imaging. We experimentally demonstrate that the optical lattices with ℓ=±50 orbital angular momentum superpositions and a clover image with nearly 200 Laguerre-Gaussian (LG) modes can be well encoded and successfully decoded. It is found that an image encoded/decoded with a two-index LG spectrum (considering both azimuthal and radial indices, ℓ and p) possesses much higher fidelity than that with a one-index LG spectrum (only considering the ℓ index). Our work provides an alternative tool for the image encoding/decoding scheme toward free-space optical communications.

  19. Energy harvesting in high voltage measuring techniques

    Science.gov (United States)

    Żyłka, Pawel; Doliński, Marcin

    2016-02-01

    The paper discusses selected problems related to application of energy harvesting (that is, generating electricity from surplus energy present in the environment) to supply autonomous ultra-low-power measurement systems applicable in high voltage engineering. As a practical example of such implementation a laboratory model of a remote temperature sensor is presented, which is self-powered by heat generated in a current-carrying busbar in HV- switchgear. Presented system exploits a thermoelectric harvester based on a passively cooled Peltier module supplying micro-power low-voltage dc-dc converter driving energy-efficient temperature sensor, microcontroller and a fibre-optic transmitter. Performance of the model in laboratory simulated conditions are presented and discussed.

  20. Benchmarking of Voltage Sag Generators

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede; Zou, Zhixiang

    2012-01-01

    to guide these grid-connected distributed power generation systems. In order to verify the response of such systems for voltage disturbance, mainly for evaluation of voltage sags/dips, a Voltage Sag Generator (VSG) is needed. This paper evaluates such sag test devices according to IEC 61000 in order...... to provide cheaper solutions to test against voltage sags. Simulation and experimental results demonstrate that the shunt impedance based VSG solution is the easiest and cheapest one for laboratory test applications. The back-to-back fully controlled converter based VSG is the most flexible solution......The increased penetration of renewable energy systems, like photovoltaic and wind power systems, rises the concern about the power quality and stability of the utility grid. Some regulations for Low Voltage Ride-Through (LVRT) for medium voltage or high voltage applications, are coming into force...

  1. High speed image acquisition system of absolute encoder

    Science.gov (United States)

    Liao, Jianxiang; Chen, Xin; Chen, Xindu; Zhang, Fangjian; Wang, Han

    2017-01-01

    Absolute optical encoder as a product of optical, mechanical and electronic integration has been widely used in displacement measuring fields. However, how to improve the measurement velocity and reduce the manufacturing cost of absolute optical encoder is the key problem to be solved. To improve the measurement speed, a novel absolute optical encoder image acquisition system is proposed. The proposed acquisition system includes a linear CCD sensor is applied for capturing coding pattern images, an optical magnifying system is used for enlarging the grating stripes, an analog-digital conversion(ADC) module is used for processing the CCD analogy signal, a field programmable gate array(FPGA) device and other peripherals perform driving task. An absolute position measurement experiment was set up to verify and evaluate the proposed image acquisition system. The experimental result indicates that the proposed absolute optical encoder image acquisition system has the image acquisition speed of more than 9500fp/s with well reliability and lower manufacture cost.

  2. Heat-pump performance: voltage dip/sag, under-voltage and over-voltage

    Directory of Open Access Journals (Sweden)

    William J.B. Heffernan

    2014-12-01

    Full Text Available Reverse cycle air-source heat-pumps are an increasingly significant load in New Zealand and in many other countries. This has raised concern over the impact wide-spread use of heat-pumps may have on the grid. The characteristics of the loads connected to the power system are changing because of heat-pumps. Their performance during under-voltage events such as voltage dips has the potential to compound the event and possibly cause voltage collapse. In this study, results from testing six heat-pumps are presented to assess their performance at various voltages and hence their impact on voltage stability.

  3. Coordinated Voltage Control of Distributed PV Inverters for Voltage Regulation in Low Voltage Distribution Networks

    DEFF Research Database (Denmark)

    Nainar, Karthikeyan; Pokhrel, Basanta Raj; Pillai, Jayakrishnan Radhakrishna

    2017-01-01

    This paper reviews and analyzes the existing voltage control methods of distributed solar PV inverters to improve the voltage regulation and thereby the hosting capacity of a low-voltage distribution network. A novel coordinated voltage control method is proposed based on voltage sensitivity...... analysis, which is simple for computation and requires moderate automation and communication infrastructure. The proposed method is suitable for a hierarchical control structure where a supervisory controller has the provision to adapt the settings of local PV inverter controllers for overall system...

  4. DMD-based spatially Fourier-encoded photoacoustic microscopy

    Science.gov (United States)

    Liang, Jinyang; Gao, Liang; Li, Chiye; Wang, Lihong V.

    2015-03-01

    We present spatially Fourier-encoded photoacoustic microscopy using a digital micromirror device (DMD). The spatial fluence distribution of laser pulses is Fourier-encoded by the DMD, and a series of such encoded photoacoustic (PA) measurements enables decoding of the spatial distribution of optical absorption. By imaging a chromium target, we demonstrated the throughput and Fellgett advantages, which increased the PA signal-to-noise ratio (SNR) compared to raster scanning. The system was used to image two biological targets, a monolayer of red blood cells, and melanoma cells. The enhanced SNR benefited PA images by increasing the image's contrast-to-noise ratio and target identifiability.

  5. Encoding the Factorisation Calculus

    Directory of Open Access Journals (Sweden)

    Reuben N. S. Rowe

    2015-08-01

    Full Text Available Jay and Given-Wilson have recently introduced the Factorisation (or SF- calculus as a minimal fundamental model of intensional computation. It is a combinatory calculus containing a special combinator, F, which is able to examine the internal structure of its first argument. The calculus is significant in that as well as being combinatorially complete it also exhibits the property of structural completeness, i.e. it is able to represent any function on terms definable using pattern matching on arbitrary normal forms. In particular, it admits a term that can decide the structural equality of any two arbitrary normal forms. Since SF-calculus is combinatorially complete, it is clearly at least as powerful as the more familiar and paradigmatic Turing-powerful computational models of Lambda Calculus and Combinatory Logic. Its relationship to these models in the converse direction is less obvious, however. Jay and Given-Wilson have suggested that SF-calculus is strictly more powerful than the aforementioned models, but a detailed study of the connections between these models is yet to be undertaken. This paper begins to bridge that gap by presenting a faithful encoding of the Factorisation Calculus into the Lambda Calculus preserving both reduction and strong normalisation. The existence of such an encoding is a new result. It also suggests that there is, in some sense, an equivalence between the former model and the latter. We discuss to what extent our result constitutes an equivalence by considering it in the context of some previously defined frameworks for comparing computational power and expressiveness.

  6. Voltage-sensitive rhodol with enhanced two-photon brightness.

    Science.gov (United States)

    Kulkarni, Rishikesh U; Kramer, Daniel J; Pourmandi, Narges; Karbasi, Kaveh; Bateup, Helen S; Miller, Evan W

    2017-03-14

    We have designed, synthesized, and applied a rhodol-based chromophore to a molecular wire-based platform for voltage sensing to achieve fast, sensitive, and bright voltage sensing using two-photon (2P) illumination. Rhodol VoltageFluor-5 (RVF5) is a voltage-sensitive dye with improved 2P cross-section for use in thick tissue or brain samples. RVF5 features a dichlororhodol core with pyrrolidyl substitution at the nitrogen center. In mammalian cells under one-photon (1P) illumination, RVF5 demonstrates high voltage sensitivity (28% ΔF/F per 100 mV) and improved photostability relative to first-generation voltage sensors. This photostability enables multisite optical recordings from neurons lacking tuberous sclerosis complex 1, Tsc1, in a mouse model of genetic epilepsy. Using RVF5, we show that Tsc1 KO neurons exhibit increased activity relative to wild-type neurons and additionally show that the proportion of active neurons in the network increases with the loss of Tsc1. The high photostability and voltage sensitivity of RVF5 is recapitulated under 2P illumination. Finally, the ability to chemically tune the 2P absorption profile through the use of rhodol scaffolds affords the unique opportunity to image neuronal voltage changes in acutely prepared mouse brain slices using 2P illumination. Stimulation of the mouse hippocampus evoked spiking activity that was readily discerned with bath-applied RVF5, demonstrating the utility of RVF5 and molecular wire-based voltage sensors with 2P-optimized fluorophores for imaging voltage in intact brain tissue.

  7. Diagnosis of High Voltage Insulators Made of Ceramic Using Spectrophotometry

    Directory of Open Access Journals (Sweden)

    Paweł Frącz

    2016-01-01

    Full Text Available The paper presents results of comparative analysis of optical signals emitted by partial discharges occurring on three types of high voltage insulators made of porcelain. The research work consisted of diagnosis of the following devices: a long rod insulator, a cap insulator, and an insulating cylinder. For optical signal registration a spectrophotometer was applied. All measurements were performed under laboratory conditions by changing the value of partial discharges generation voltage. For the cylindrical insulator also the distance between high voltage and ground electrodes was subjected for investigation as a factor having influence on partial discharges. The main contribution which resulted from the studies is statement that application of spectrophotometer enables faster recognition of partial discharges, as compared to standard methods.

  8. Voltage Dependence of Supercapacitor Capacitance

    Directory of Open Access Journals (Sweden)

    Szewczyk Arkadiusz

    2016-09-01

    Full Text Available Electronic Double-Layer Capacitors (EDLC, called Supercapacitors (SC, are electronic devices that are capable to store a relatively high amount of energy in a small volume comparing to other types of capacitors. They are composed of an activated carbon layer and electrolyte solution. The charge is stored on electrodes, forming the Helmholtz layer, and in electrolyte. The capacitance of supercapacitor is voltage- dependent. We propose an experimental method, based on monitoring of charging and discharging a supercapacitor, which enables to evaluate the charge in an SC structure as well as the Capacitance-Voltage (C-V dependence. The measurement setup, method and experimental results of charging/discharging commercially available supercapacitors in various voltage and current conditions are presented. The total charge stored in an SC structure is proportional to the square of voltage at SC electrodes while the charge on electrodes increases linearly with the voltage on SC electrodes. The Helmholtz capacitance increases linearly with the voltage bias while a sublinear increase of total capacitance was found. The voltage on SC increases after the discharge of electrodes due to diffusion of charges from the electrolyte to the electrodes. We have found that the recovery voltage value is linearly proportional to the initial bias voltage value.

  9. using photo-induced open-circuit voltage

    African Journals Online (AJOL)

    silicon solar cells. The values obtained at room temperature are in good agreement with reference values. Key words/phrases: Diffusion length, minority .... THEORY. With the help of the photoinduced open~circuit voltage decay technique, excess minority carriers are created in a junction device using an external optical.

  10. Effect of the electrode material on the breakdown voltage and space charge distribution of propylene carbonate under impulse voltage

    Directory of Open Access Journals (Sweden)

    Qing Yang

    2016-04-01

    Full Text Available This paper reports three types of electrode materials (copper, aluminum, and stainless steel that are used to measure the impulse breakdown voltage of propylene carbonate. The breakdown voltage of propylene carbonate with these electrode materials is different and is in decreasing order of stainless steel, copper, and aluminum. To explore how the electrode material affects the insulating properties of the liquid dielectric, the electric field distribution and space charge distribution of propylene carbonate under impulse voltage with the three electrode materials are measured on the basis of a Kerr electro-optic test. The space charge injection ability is highest for aluminum, followed by copper, and then the stainless steel electrodes. Furthermore, the electric field distortion rate decreased in the order of the aluminum, copper, and then the stainless steel electrode. This paper explains that the difference in the electric field distortion rate between the three electrode materials led to the difference in the impulse breakdown voltage of propylene carbonate.

  11. A GRISM-based probe for spectrally encoded confocal microscopy.

    Science.gov (United States)

    Pitris, C; Bouma, B; Shiskov, M; Tearney, G

    2003-01-27

    Spectrally encoded confocal microscopy (SECM) is a novel approach for obtaining high resolution, depth-sectioned images of microstructure within turbid samples. By encoding one spatial dimension in wavelength, imaging probes can be greatly simplified compared to standard scanning confocal microscopes, potentially enabling endoscopic implementation. The use of a diffraction grating for spectral encoding, however, skews the optical axis through the probe, thus complicating the design of narrow diameter instruments. In this Letter, we describe a novel use of a single-optical-axis element based on high index-of-refraction prisms and a transmission holographic grating for the design of narrow diameter SECM devices. Confocal images obtained with a 10.0 mm probe demonstrate a transverse resolution of 1.1 microm and a field of view of 650 microm.

  12. Detecting Faults from Encoded Information

    NARCIS (Netherlands)

    Persis, Claudio De

    2003-01-01

    The problem of fault detection for linear continuous-time systems via encoded information is considered. The encoded information is received at a remote location by the monitoring deiice and assessed to infer the occurrence of the fault. A class of faults is considered which allows to use a simple

  13. Electronic Current Transducer (ECT) for high voltage dc lines

    Science.gov (United States)

    Houston, J. M.; Peters, P. H., Jr.; Summerayes, H. R., Jr.; Carlson, G. J.; Itani, A. M.

    1980-02-01

    The development of a bipolar electronic current transducer (ECT) for measuring the current in a high voltage dc (HVDC) power line at line potential is discussed. The design and construction of a free standing ECT for use on a 400 kV line having a nominal line current of 2000 A is described. Line current is measured by a 0.0001 ohm shunt whose voltage output is sampled by a 14 bit digital data link. The high voltage interface between line and ground is traversed by optical fibers which carry digital light signals as far as 300 m to a control room where the digital signal is converted back to an analog representation of the shunt voltage. Two redundant electronic and optical data links are used in the prototype. Power to operate digital and optical electronics and temperature controlling heaters at the line is supplied by a resistively and capacitively graded 10 stage cascade of ferrite core transformers located inside the hollow, SF6 filled, porcelain support insulator. The cascade is driven by a silicon controlled rectifier inverter which supplies about 100 W of power at 30 kHz.

  14. The Voltage Boost Enabled by Luminescence Extraction in Solar Cells

    Energy Technology Data Exchange (ETDEWEB)

    Ganapati, Vidya; Steiner, Myles A.; Yablonovitch, Eli

    2016-11-21

    A new physical principle has emerged to produce record voltages and efficiencies in photovoltaic cells, 'luminescence extraction.' This is exemplified by the mantra 'a good solar cell should also be a good LED.' Luminescence extraction is the escape of internal photons out of the front surface of a solar cell. Basic thermodynamics says that the voltage boost should be related to concentration ratio, C, of a resource by ..delta..V=(kT/q)ln{C}. In light trapping, (i.e. when the solar cell is textured and has a perfect back mirror) the concentration ratio of photons C={4n2}, so one would expect a voltage boost of ..delta..V=kT ln{4n2} over a solar cell with no texture and zero back reflectivity, where n is the refractive index. Nevertheless, there has been ambiguity over the voltage benefit to be expected from perfect luminescence extraction. Do we gain an open circuit voltage boost of ..delta..V=(kT/q)ln{n2}, ..delta..V=(kT/q)ln{2n2}, or ..delta..V=(kT/q)ln{4n2}? What is responsible for this voltage ambiguity ..delta..V=(kT/q)ln{4}=36mVolts? We show that different results come about, depending on whether the photovoltaic cell is optically thin or thick to its internal luminescence. In realistic intermediate cases of optical thickness the voltage boost falls in between; ln{n2}q..delta..V/kT)<;ln{4n2}.

  15. Voltage Sensors Monitor Harmful Static

    Science.gov (United States)

    2009-01-01

    A tiny sensor, small enough to be worn on clothing, now monitors voltage changes near sensitive instruments after being created to alert Agency workers to dangerous static buildup near fuel operations and avionics. San Diego s Quasar Federal Systems received a Small Business Innovation Research (SBIR) contract from Kennedy Space Center to develop its remote voltage sensor (RVS), a dime-sized electrometer designed to measure triboelectric changes in the environment. One of the unique qualities of the RVS is that it can detect static at greater distances than previous devices, measuring voltage changes from a few centimeters to a few meters away, due to its much-improved sensitivity.

  16. Power-MOSFET Voltage Regulator

    Science.gov (United States)

    Miller, W. N.; Gray, O. E.

    1982-01-01

    Ninety-six parallel MOSFET devices with two-stage feedback circuit form a high-current dc voltage regulator that also acts as fully-on solid-state switch when fuel-cell out-put falls below regulated voltage. Ripple voltage is less than 20 mV, transient recovery time is less than 50 ms. Parallel MOSFET's act as high-current dc regulator and switch. Regulator can be used wherever large direct currents must be controlled. Can be applied to inverters, industrial furnaces photovoltaic solar generators, dc motors, and electric autos.

  17. voltage compensation using artificial neural network

    African Journals Online (AJOL)

    Offor Theophilos

    VOLTAGE COMPENSATION USING ARTIFICIAL NEURAL NETWORK: A CASE STUDY OF. RUMUOLA ... using artificial neural network (ANN) controller based dynamic voltage restorer (DVR). ... substation by simulating with sample of average voltage for Omerelu, Waterlines, Rumuola, Shell Industrial and Barracks.

  18. Modular High Voltage Power Supply

    Energy Technology Data Exchange (ETDEWEB)

    Newell, Matthew R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-18

    The goal of this project is to develop a modular high voltage power supply that will meet the needs of safeguards applications and provide a modular plug and play supply for use with standard electronic racks.

  19. A Voltage Quality Detection Method

    DEFF Research Database (Denmark)

    Chen, Zhe; Wei, Mu

    2008-01-01

    This paper presents a voltage quality detection method based on a phase-locked loop (PLL) technique. The technique can detect the voltage magnitude and phase angle of each individual phase under both normal and fault power system conditions. The proposed method has the potential to evaluate various...... power quality disturbances, such as interruptions, sags and imbalances. Simulation studies have been performed. The effectiveness of the proposed method has been demonstrated under the simulated typical power disturbances....

  20. Medium voltage substation insulation coordination

    Energy Technology Data Exchange (ETDEWEB)

    Caccia, M.; Gambirasio, D. (SAE Sadelmi, Milan (Italy))

    1991-01-01

    With reference to the provisions contained in applicable CEI (Italian Electrotechnical Committee) and IEC (International Electrotechnical Commission) normatives, a review is made of design criteria for the coordination of medium voltage substation switchgear and control gear. The design problematics are discussed with reference to optimization of neutral grounding, three phase ac short circuit calculation methods, and methods for the evaluation of voltages in fault conditions.

  1. Reliability criteria for voltage stability

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Carson W.; Silverstein, Brian L. [Bonneville Power Administration, Portland, OR (United States)

    1994-12-31

    In face of costs pressures, there is need to allocate scare resources more effectively in order to achieve voltage stability. This naturally leads to development of probabilistic criteria and notions of rick management. In this paper it is presented a discussion about criteria for long term voltage stability limited to the case in which the time frames are topically several minutes. (author) 14 refs., 1 fig.

  2. Palette of fluorinated voltage-sensitive hemicyanine dyes

    Science.gov (United States)

    Yan, Ping; Acker, Corey D.; Zhou, Wen-Liang; Lee, Peter; Bollensdorff, Christian; Negrean, Adrian; Lotti, Jacopo; Sacconi, Leonardo; Antic, Srdjan D.; Kohl, Peter; Mansvelder, Huibert D.; Pavone, Francesco S.; Loew, Leslie M.

    2012-01-01

    Optical recording of membrane potential permits spatially resolved measurement of electrical activity in subcellular regions of single cells, which would be inaccessible to electrodes, and imaging of spatiotemporal patterns of action potential propagation in excitable tissues, such as the brain or heart. However, the available voltage-sensitive dyes (VSDs) are not always spectrally compatible with newly available optical technologies for sensing or manipulating the physiological state of a system. Here, we describe a series of 19 fluorinated VSDs based on the hemicyanine class of chromophores. Strategic placement of the fluorine atoms on the chromophores can result in either blue or red shifts in the absorbance and emission spectra. The range of one-photon excitation wavelengths afforded by these new VSDs spans 440–670 nm; the two-photon excitation range is 900–1,340 nm. The emission of each VSD is shifted by at least 100 nm to the red of its one-photon excitation spectrum. The set of VSDs, thus, affords an extended toolkit for optical recording to match a broad range of experimental requirements. We show the sensitivity to voltage and the photostability of the new VSDs in a series of experimental preparations ranging in scale from single dendritic spines to whole heart. Among the advances shown in these applications are simultaneous recording of voltage and calcium in single dendritic spines and optical electrophysiology recordings using two-photon excitation above 1,100 nm. PMID:23169660

  3. Macroeconomic Assessment of Voltage Sags

    Directory of Open Access Journals (Sweden)

    Sinan Küfeoğlu

    2016-12-01

    Full Text Available The electric power sector has changed dramatically since the 1980s. Electricity customers are now demanding uninterrupted and high quality service from both utilities and authorities. By becoming more and more dependent on the voltage sensitive electronic equipment, the industry sector is the one which is affected the most by voltage disturbances. Voltage sags are one of the most crucial problems for these customers. The utilities, on the other hand, conduct cost-benefit analyses before going through new investment projects. At this point, understanding the costs of voltage sags become imperative for planning purposes. The characteristics of electric power consumption and hence the susceptibility against voltage sags differ considerably among different industry subsectors. Therefore, a model that will address the estimation of worth of electric power reliability for a large number of customer groups is necessary. This paper introduces a macroeconomic model to calculate Customer Voltage Sag Costs (CVSCs for the industry sector customers. The proposed model makes use of analytical data such as value added, annual energy consumption, working hours, and average outage durations and provides a straightforward, credible, and easy to follow methodology for the estimation of CVSCs.

  4. Spatially Fourier-encoded photoacoustic microscopy using a digital micromirror device

    OpenAIRE

    Liang, Jinyang; Gao, Liang; Li, Chiye; Wang, Lihong V.

    2014-01-01

    We have developed spatially Fourier-encoded photoacoustic microscopy using a digital micromirror device. The spatial intensity distribution of laser pulses is Fourier-encoded, and a series of such encoded photoacoustic measurements allows one to decode the spatial distribution of optical absorption. The throughput and Fellgett advantages were demonstrated by imaging a chromium target. By using 63 spatial elements, the signal-to-noise ratio in the recovered photoacoustic signal was enhanced by...

  5. New concepts in PCM encoding

    Science.gov (United States)

    Yun, Paul M.

    The Pulse Coded Modulation (PCM) Encoder Systems used in telemetry have gained enormous flexibility for various applications because the input data channels and frame sync codes are programmable via the EEPROMs or UVEPROMs. The firmware in the current PCM Encoder Systems can be readily tailored for a specific application to monitor numerous types of analog channels, as well as digital channels. However, the current PCM Encoder Systems require several types of strap options which dictate not only a limited choice of gains and offsets, but also a fixed choice of the premodulation filter characteristics. The brain of the 1000 PCM Encoder is the Digital Signal Processor (DSP) which eliminates the fixed premodulation filter characteristics via digital filter functions, and also eliminates strap options via general purpose microprocessor functions.

  6. Encoding mutually unbiased bases in orbital angular momentum for quantum key distribution

    CSIR Research Space (South Africa)

    Dudley, Angela L

    2013-07-01

    Full Text Available We encode mutually unbiased bases (MUBs) using the higher-dimensional orbital angular momentum (OAM) degree of freedom associated with optical fields. We illustrate how these states are encoded with the use of a spatial light modulator (SLM). We...

  7. Digital measurement system for the LHC klystron high voltage modulator.

    CERN Document Server

    Mikkelsen, Anders

    Accelerating voltage in the Large Hadron Collider (LHC) is created by a means of 16 superconducting standing wave RF cavities, each fed by a 400MHz/300kW continuous wave klystron amplifier. Part of the upgrade program for the LHC long shutdown one is to replace the obsolete analogue current and voltage measurement circuitry located in the high voltage bunkers by a new, digital system, using ADCs and optical fibres. A digital measurement card is implemented and integrated into the current HV modulator oil tank (floating at -58kV) and interfaced to the existing digital VME boards collecting the data for several klystrons at the ground potential. Measured signals are stored for the logging, diagnostics and post-mortem analysis purposes.

  8. Biophysical characterization of the fluorescent protein voltage probe VSFP2.3 based on the voltage-sensing domain of Ci-VSP

    DEFF Research Database (Denmark)

    Lundby, Alicia; Akemann, Walther; Knöpfel, Thomas

    2010-01-01

    as a monomer. We fused the voltage-sensing domain of Ci-VSP to a pair of fluorescent reporter proteins to generate a genetically encodable voltage-sensing fluorescent probe, VSFP2.3. VSFP2.3 is a fluorescent voltage probe that reports changes in membrane potential as a FRET (fluorescence resonance energy....... Neutralization of an arginine in S4, previously suggested to be a sensing charge, and measuring associated sensing currents indicate that this charge is likely to reside at the membrane-aqueous interface rather than within the membrane electric field. The data presented give us insights into the voltage......-sensing mechanism of Ci-VSP, which will allow us to further improve the sensitivity and kinetics of the family of VSFP proteins....

  9. Polarization states encoded by phase modulation for high bit rate quantum key distribution

    Science.gov (United States)

    Liu, Xiaobao; Tang, Zhilie; Liao, Changjun; Lu, Yiqun; Zhao, Feng; Liu, Songhao

    2006-10-01

    We present implementation of quantum cryptography with polarization code by wave-guide type phase modulator. At four different low input voltages of the phase modulator, coder encodes pulses into four different polarization states, 45°, 135° linearly polarized or right, left circle polarized, while the decoder serves as the complementary polarizers.

  10. Unbalanced Voltage Compensation in Low Voltage Residential AC Grids

    DEFF Research Database (Denmark)

    Trintis, Ionut; Douglass, Philip; Munk-Nielsen, Stig

    2016-01-01

    This paper describes the design and test of a control algorithm for active front-end rectifiers that draw power from a residential AC grid to feed heat pump loads. The control algorithm is able to control the phase to neutral or phase to phase RMS voltages at the point of common coupling. The vol......This paper describes the design and test of a control algorithm for active front-end rectifiers that draw power from a residential AC grid to feed heat pump loads. The control algorithm is able to control the phase to neutral or phase to phase RMS voltages at the point of common coupling....... The voltage control was evaluated with either active or reactive independent phase load current control. The control performance in field operation in a residential grid situated in Bornholm, Denmark was investigated for different use cases....

  11. Optical Angular Motion Sensor

    Science.gov (United States)

    1977-05-31

    of autocollimation is the requirement for hig’ quality optics over the measurement range. For arc- second resolution difirfction limited optics is a...16 No,,. 63 Quality Program Requirements USAF Specifica- 3 Nov. 59 Control of Non-conforming tion Bulletin 515 Supplies SAMSO CEI Spec. 31 Dec. 72...ibilitv to gain amplifiers (12), and the output from these amplifiers is supplied as the contril voltage to the analog divider (14) which supplies

  12. Optics/Optical Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Optics/Optical Diagnostics Laboratory supports graduate instruction in optics, optical and laser diagnostics and electro-optics. The optics laboratory provides...

  13. Electrode voltage fall and total voltage of a transient arc

    Science.gov (United States)

    Valensi, F.; Ratovoson, L.; Razafinimanana, M.; Masquère, M.; Freton, P.; Gleizes, A.

    2016-06-01

    This paper deals with an experimental study of the components of a transient arc total voltage with duration of a few tens of ms and a current peak close to 1000 A. The cathode tip is made of graphite whereas the flat anode is made either of copper or of graphite; the electrodes gap is a few mm. The analysis of the electrical parameters is supported and validated by fast imaging and by two models: the first one is a 2D physical model of the arc allowing to calculate both the plasma temperature field and the arc voltage; the second model is able to estimate the transient heating of the graphite electrode. The main aim of the study was to detect the possible change of the cathode voltage fall (CVF) during the first instants of the arc. Indeed it is expected that during the first ms the graphite cathode is rather cool and the main mechanism of the electron emission should be the field effect emission, whereas after several tens of ms the cathode is strongly heated and thermionic emission should be predominant. We have observed some change in the apparent CVF but we have shown that this apparent change can be attributed to the variation of the solid cathode resistance. On the other hand, the possible change of CVF corresponding to the transition between a ‘cold’ and a ‘hot’ cathode should be weak and could not be characterized considering our measurement uncertainty of about 2 V. The arc column voltage (ACV) was estimated by subtracting the electrode voltage fall from the total arc voltage. The experimental transient evolution of the ACV is in very good agreement with the theoretical variation predicted by the model, showing the good ability of the model to study this kind of transient arc.

  14. Automated Voltage Control in LHCb

    CERN Document Server

    Granado Cardoso, L; Jacobsson, R

    2011-01-01

    LHCb is one of the 4 LHC experiments. In order to ensure the safety of the detector and to maximize efficiency, LHCb needs to coordinate its own operations, in particular the voltage configuration of the different subdetectors, according to the accelerator status. A control software has been developed for this purpose, based on the Finite State Machine toolkit and the SCADA system used for control throughout LHCb (and the other LHC experiments). This software permits to efficiently drive both the Low Voltage (LV) and High Voltage (HV) systems of the 10 different sub-detectors that constitute LHCb, setting each sub-system to the required voltage (easily configurable at run-time) based on the accelerator state. The control software is also responsible for monitoring the state of the Sub-detector voltages and adding it to the event data in the form of status-bits. Safe and yet flexible operation of the LHCb detector has been obtained and automatic actions, triggered by the state changes of the ...

  15. New Role of P/Q-type Voltage-gated Calcium Channels

    DEFF Research Database (Denmark)

    Hansen, Pernille B L

    2015-01-01

    Voltage-gated calcium channels are important for the depolarization-evoked contraction of vascular smooth muscle cells (SMCs), with L-type channels being the classical channel involved in this mechanism. However, it has been demonstrated that the CaV2.1 subunit, which encodes a neuronal isoform o...

  16. Compact plasmonic variable optical attenuator

    DEFF Research Database (Denmark)

    Leosson, Kristjan; Rosenzveig, Tiberiu; Hermannsson, Pétur Gordon

    2008-01-01

    We demonstrate plasmonic nanowire-based thermo-optic variable optical attenuators operating in the 1525-1625 nm wavelength range. The devices have a footprint as low as 1 mm, extinction ratio exceeding 40 dB, driving voltage below 3 V, and full modulation bandwidth of 1 kHz. The polarization...

  17. Development of a New Cascade Voltage-Doubler for Voltage Multiplication

    Directory of Open Access Journals (Sweden)

    Arash Toudeshki

    2014-01-01

    Full Text Available For more than eight decades, cascade voltage-doubler circuits are used as a method to produce DC output voltage higher than the input voltage. In this paper, the topological developments of cascade voltage-doublers are reviewed. A new circuit configuration for cascade voltage-doubler is presented. This circuit can produce a higher value of the DC output voltage and better output quality compared to the conventional cascade voltage-doubler circuits, with the same number of stages.

  18. Development of a New Cascade Voltage-Doubler for Voltage Multiplication

    OpenAIRE

    Toudeshki, Arash; Mariun, Norman; Hizam, Hashim; Abdul Wahab, Noor Izzri

    2014-01-01

    For more than eight decades, cascade voltage-doubler circuits are used as a method to produce DC output voltage higher than the input voltage. In this paper, the topological developments of cascade voltage-doublers are reviewed. A new circuit configuration for cascade voltage-doubler is presented. This circuit can produce a higher value of the DC output voltage and better output quality compared to the conventional cascade voltage-doubler circuits, with the same number of stages.

  19. Low-Energy Real-Time OS Using Voltage Scheduling Algorithm for Variable Voltage Processors

    OpenAIRE

    Okuma, Takanori; Yasuura, Hiroto

    2001-01-01

    This paper presents a real-time OS based on $ mu $ITRON using proposed voltage scheduling algorithm for variable voltage processors which can vary supply voltage dynamically. The proposed voltage scheduling algorithms assign voltage level for each task dynamically in order to minimize energy consumption under timing constraints. Using the presented real-time OS, running tasks with low supply voltage leads to drastic energy reduction. In addition, the presented voltage scheduling algorithm is ...

  20. Voltage Quality of Grid Connected Wind Turbines

    DEFF Research Database (Denmark)

    Chen, Zhe; Blaabjerg, Frede; Sun, Tao

    2004-01-01

    Grid connected wind turbines may cause quality problems, such as voltage variation and flicker. This paper discusses the voltage variation and flicker emission of grid connected wind turbines with doubly-fed induction generators. A method to compensate flicker by using a voltage source converter...... (VSC) based STATCOM is presented, which shows it is an efficient mean to improve voltage quality....

  1. Linear encoder based low frequency inertial sensor

    Directory of Open Access Journals (Sweden)

    Collette Christophe

    2015-01-01

    Full Text Available For many applications, there is an increasing demand for low cost, high-resolution inertial sensors, which are capable of operating in harsh environments. Recently, a prototype of small optical inertial sensor has been built, using a Michelson interferometer. A resolution of 3 pm/√Hz has been obtained above 4 Hz using only low cost components. Compared to most state-of-the-art devices, this prototype did not contain any coil, which offers several important advantages, including a low thermal noise in the suspension and a full compatibility with magnetic environments (like particle collider. On the other hand, the Michelson is known to be tricky to tune, especially when one attempts to miniaturize the sensor. In this paper, we will propose a novel concept of inertial sensor, based on a linear encoder. Compared to the Michelson, the encoder is much more easy to mount, and the calibration more stable. The price to pay is a reduced resolution. In order to overcome this limitation, we amplify mechanically the relative motion between the support and the inertial mass. First results obtained with the new sensor will be discussed, and compared with the Michelson inertial sensor.

  2. Voltage control of droplet interface bilayer lipid membrane dimensions.

    Science.gov (United States)

    Punnamaraju, Srikoundinya; Steckl, Andrew J

    2011-01-18

    A novel approach to control the area of anchor-free droplet interface bilayer (DIB) lipid membranes is presented. Unsupported DIB lipid membranes are formed at the interface of phospholipid-coated aqueous droplets dispensed in dodecane oil. Using electrodes inserted into the droplets, an external voltage is applied which modulates the effective DIB area. Electrical (capacitance or current) and optical (imaging of DIB lateral length) recordings were simultaneously performed. Alpha-hemolysin (αHL) single channel insertions into the DIB were recorded. Currents across the DIB were measured as a function of voltage and αHL concentration in the droplets. Nonlinear response is observed for current, DIB lateral length and area, and capacitance with respect to voltage. Voltage induced changes in interfacial tension modulated the DIB-oil contact angle and the membrane contact length, which provided control of membrane dimensions. Comparison of these results is made to the electrowetting effect, which is also governed by effect of voltage on the interfacial tension. This approach provides active control of the number of ion channels inserted into the DIB.

  3. Polymer-dispersed liquid-crystal voltage sensor.

    Science.gov (United States)

    Scherschener, Elizabeth; Perciante, César D; Dalchiele, Enrique A; Frins, Erna M; Korn, Matthias; Ferrari, José A

    2006-05-20

    We present a novel electric-field and voltage sensor based on the electro-optical properties of polymer-dispersed liquid-crystals (PDLCs). In principle, the transmittance of PDLCs is a nonlinear function of the applied electrical field. To measure an AC field we superposed to it a known DC field. This allowed us to achieve linearization of the PDLC response and to measure transmittance changes independently of the light-intensity level variations. Validation experiments are presented.

  4. Portable High Voltage Impulse Generator

    Directory of Open Access Journals (Sweden)

    S. Gómez

    2011-06-01

    Full Text Available This paper presents a portable high voltage impulse generator which was designed and built with insulation up to 20 kV. This design was based on previous work in which simulation software for standard waves was developed. Commercial components and low-cost components were used in this work; however, these particular elements are not generally used for high voltage applications. The impulse generators used in industry and laboratories are usually expensive; they are built to withstand extra high voltage and they are big, making them impossible to transport. The proposed generator is portable, thereby allowing tests to be made on devices that cannot be moved from their location. The results obtained with the proposed impulse generator were satisfactory in terms of time and waveforms compared to other commercial impulse generators and the standard impulse wave simulator.

  5. Multidimensionally encoded magnetic resonance imaging.

    Science.gov (United States)

    Lin, Fa-Hsuan

    2013-07-01

    Magnetic resonance imaging (MRI) typically achieves spatial encoding by measuring the projection of a q-dimensional object over q-dimensional spatial bases created by linear spatial encoding magnetic fields (SEMs). Recently, imaging strategies using nonlinear SEMs have demonstrated potential advantages for reconstructing images with higher spatiotemporal resolution and reducing peripheral nerve stimulation. In practice, nonlinear SEMs and linear SEMs can be used jointly to further improve the image reconstruction performance. Here, we propose the multidimensionally encoded (MDE) MRI to map a q-dimensional object onto a p-dimensional encoding space where p > q. MDE MRI is a theoretical framework linking imaging strategies using linear and nonlinear SEMs. Using a system of eight surface SEM coils with an eight-channel radiofrequency coil array, we demonstrate the five-dimensional MDE MRI for a two-dimensional object as a further generalization of PatLoc imaging and O-space imaging. We also present a method of optimizing spatial bases in MDE MRI. Results show that MDE MRI with a higher dimensional encoding space can reconstruct images more efficiently and with a smaller reconstruction error when the k-space sampling distribution and the number of samples are controlled. Copyright © 2012 Wiley Periodicals, Inc.

  6. Optical Interconnection Networks

    Science.gov (United States)

    Bergman, Keren; Hughes, Gary

    2004-07-01

    In current high-performance computing and communications systems an emerging need for ultra-high-capacity, low-latency interconnection networks has led investigators to consider insertion of optical-domain switching fabrics. The use of optical technology for the physical switching layer within data communication systems is clearly advantageous in providing maximum bandwidth per cable particularly through the exploitation of DWDM. Furthermore, the transparency offered in the optical domain allows potentially wide flexibility in the data encoding and protocols. However, many key challenges remain to the successful implementation of optical packet routing, as optical signals cannot be processed efficiently or buffered for an arbitrary time. Clearly, innovative architectures, switching fabrics, and packet processing subsystems that employ optical technologies in synergetic fashions with powerful electronic techniques would be poised to harvest the immense transmission bandwidth of optics creating the ultimate "unlimited-capacity" interconnection network.

  7. Resilient architecture design for voltage variation

    CERN Document Server

    Reddi, Vijay Janapa

    2013-01-01

    Shrinking feature size and diminishing supply voltage are making circuits sensitive to supply voltage fluctuations within the microprocessor, caused by normal workload activity changes. If left unattended, voltage fluctuations can lead to timing violations or even transistor lifetime issues that degrade processor robustness. Mechanisms that learn to tolerate, avoid, and eliminate voltage fluctuations based on program and microarchitectural events can help steer the processor clear of danger, thus enabling tighter voltage margins that improve performance or lower power consumption. We describe

  8. 220-kV combined optical transformer

    Science.gov (United States)

    Cui, Ying; Ye, Miaoyuan; Zhu, Yong; Xu, Yan; Luo, Sunan

    2000-10-01

    The magneto-optic current and electro-optic voltage sensing technologies were combined into a single phase unit which provides a new solution for combined current and voltage sensing and relaying applications. It senses voltage and current by making utilities of Pockels electro-optic effect of a BGO(Bi4Ge3O12) crystal and Faraday magneto-optic effect of a close-loop flint. The 220 kV high voltage is directly applied on the BGO crystal without capacitive dividers. This design permits true optical voltage measurement to be performed for the highest possible accuracy and stability. In the current sensor, a light beam circles around the current carrying conductor. The effect of the location movement of the conductor and external magnetic field are reduced. It has superior advantages of compact size, light- weight and better performance compared with conventional current and voltage transformers. Composite bushing consisting of a fiberglass tube support and silicone rubber that is filled with SF6 gas is employed for HV insulation. Connections between the Combined Optical Transformers in the substation and the metering and protecting unit in the control house are via optical fiber cable. The fundamental principal, system design and test result of this new 220 kV Combined Optical Transformer will be introduced in this paper.

  9. Fly Photoreceptors Encode Phase Congruency.

    Directory of Open Access Journals (Sweden)

    Uwe Friederich

    Full Text Available More than five decades ago it was postulated that sensory neurons detect and selectively enhance behaviourally relevant features of natural signals. Although we now know that sensory neurons are tuned to efficiently encode natural stimuli, until now it was not clear what statistical features of the stimuli they encode and how. Here we reverse-engineer the neural code of Drosophila photoreceptors and show for the first time that photoreceptors exploit nonlinear dynamics to selectively enhance and encode phase-related features of temporal stimuli, such as local phase congruency, which are invariant to changes in illumination and contrast. We demonstrate that to mitigate for the inherent sensitivity to noise of the local phase congruency measure, the nonlinear coding mechanisms of the fly photoreceptors are tuned to suppress random phase signals, which explains why photoreceptor responses to naturalistic stimuli are significantly different from their responses to white noise stimuli.

  10. Optical Arc-Length Sensor For TIG Welding

    Science.gov (United States)

    Smith, Matthew A.

    1990-01-01

    Proposed subsystem of tungsten/inert-gas (TIG) welding system measures length of welding arc optically. Viewed by video camera, in one of three alternative optical configurations. Length of arc measured instead of inferred from voltage.

  11. Capacitor Voltages Measurement and Balancing in Flying Capacitor Multilevel Converters Utilizing a Single Voltage Sensor

    DEFF Research Database (Denmark)

    Farivar, Glen; Ghias, Amer M. Y. M.; Hredzak, Branislav

    2017-01-01

    This paper proposes a new method for measuring capacitor voltages in multilevel flying capacitor (FC) converters that requires only one voltage sensor per phase leg. Multiple dc voltage sensors traditionally used to measure the capacitor voltages are replaced with a single voltage sensor at the ac...

  12. Genetically Encoded Fluorescent Redox Probes

    Directory of Open Access Journals (Sweden)

    Hui-Wang Ai

    2013-11-01

    Full Text Available Redox processes are involved in almost every cell of the body as a consequence of aerobic life. In the past decades, redox biology has been increasingly recognized as one of the key themes in cell signaling. The progress has been accelerated by development of fluorescent probes that can monitor redox conditions and dynamics in cells and cell compartments. This short paper focuses on fluorescent redox probes that are genetically encoded, and discusses their properties, molecular mechanism, advantages and pitfalls. Our recent work on reaction-based encoded probes that are responsive to particular redox signaling molecules is also reviewed. Future challenges and directions are also commented.

  13. Genetically encoded fluorescent redox probes.

    Science.gov (United States)

    Ren, Wei; Ai, Hui-Wang

    2013-11-11

    Redox processes are involved in almost every cell of the body as a consequence of aerobic life. In the past decades, redox biology has been increasingly recognized as one of the key themes in cell signaling. The progress has been accelerated by development of fluorescent probes that can monitor redox conditions and dynamics in cells and cell compartments. This short paper focuses on fluorescent redox probes that are genetically encoded, and discusses their properties, molecular mechanism, advantages and pitfalls. Our recent work on reaction-based encoded probes that are responsive to particular redox signaling molecules is also reviewed. Future challenges and directions are also commented.

  14. A Bright and Fast Red Fluorescent Protein Voltage Indicator That Reports Neuronal Activity in Organotypic Brain Slices

    OpenAIRE

    Abdelfattah, Ahmed S.; Farhi, Samouil L.; Zhao, Yongxin; Brinks, Daan; Zou, Peng; Ruangkittisakul, Araya; Platisa, Jelena; Pieribone, Vincent A.; Ballanyi, Klaus; Cohen, Adam E.; Campbell, Robert E.

    2016-01-01

    Optical imaging of voltage indicators based on green fluorescent proteins (FPs) or archaerhodopsin has emerged as a powerful approach for detecting the activity of many individual neurons with high spatial and temporal resolution. Relative to green FP-based voltage indicators, a bright red-shifted FP-based voltage indicator has the intrinsic advantages of lower phototoxicity, lower autofluorescent background, and compatibility with blue-light-excitable channelrhodopsins. Here, we report a bri...

  15. Stabilizing Fiber-Optic Transmission Lines

    Science.gov (United States)

    Lutes, G. F.; Lau, K. Y.

    1984-01-01

    Voltage-controlled optical phase shifter is key. Optical phase shifter stabilizes propagation delay of fiber-optic transmission line by compensating for temperature and pressure effects. Applicable to phased array antenna systems and very-long-baseline interferometer distribution systems.

  16. Voltage control of ferromagnetic resonance

    Directory of Open Access Journals (Sweden)

    Ziyao Zhou

    2016-06-01

    Full Text Available Voltage control of magnetism in multiferroics, where the ferromagnetism and ferroelectricity are simultaneously exhibiting, is of great importance to achieve compact, fast and energy efficient voltage controllable magnetic/microwave devices. Particularly, these devices are widely used in radar, aircraft, cell phones and satellites, where volume, response time and energy consumption is critical. Researchers realized electric field tuning of magnetic properties like magnetization, magnetic anisotropy and permeability in varied multiferroic heterostructures such as bulk, thin films and nanostructure by different magnetoelectric (ME coupling mechanism: strain/stress, interfacial charge, spin–electromagnetic (EM coupling and exchange coupling, etc. In this review, we focus on voltage control of ferromagnetic resonance (FMR in multiferroics. ME coupling-induced FMR change is critical in microwave devices, where the electric field tuning of magnetic effective anisotropic field determines the tunability of the performance of microwave devices. Experimentally, FMR measurement technique is also an important method to determine the small effective magnetic field change in small amount of magnetic material precisely due to its high sensitivity and to reveal the deep science of multiferroics, especially, voltage control of magnetism in novel mechanisms like interfacial charge, spin–EM coupling and exchange coupling.

  17. (ann) based dynamic voltage restorer

    African Journals Online (AJOL)

    HOD

    artificial intelligence to provide smart triggering pulses for the DVR to mitigate and to provide compensation against voltage sags and swells. The Artificial Neural Network (ANN) was trained ... 90% of the nominal rms value and lasting for 0.5cycles. (10msec for 50Hz power system) up to 1 minute. It is considered as the most ...

  18. Nonlinear electrokinetics at large voltages

    Energy Technology Data Exchange (ETDEWEB)

    Bazant, Martin Z [Department of Chemical Engineering and Institute for Soldier Nanotechnologies, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Sabri Kilic, Mustafa; Ajdari, Armand [Department of Mathematics, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Storey, Brian D [Franklin W Olin College of Engineering, Needham, MA 02492 (United States)], E-mail: bazant@mit.edu

    2009-07-15

    The classical theory of electrokinetic phenomena assumes a dilute solution of point-like ions in chemical equilibrium with a surface whose double-layer voltage is of order the thermal voltage, k{sub B}T/e=25 mV. In nonlinear 'induced-charge' electrokinetic phenomena, such as ac electro-osmosis, several volts {approx}100k{sub B}T/e are applied to the double layer, and the theory breaks down and cannot explain many observed features. We argue that, under such a large voltage, counterions 'condense' near the surface, even for dilute bulk solutions. Based on simple models, we predict that the double-layer capacitance decreases and the electro-osmotic mobility saturates at large voltages, due to steric repulsion and increased viscosity of the condensed layer, respectively. The former suffices to explain observed high-frequency flow reversal in ac electro-osmosis; the latter leads to a salt concentration dependence of induced-charge flows comparable to experiments, although a complete theory is still lacking.

  19. High-Voltage Droplet Dispenser

    Science.gov (United States)

    Eichenberg, Dennis J.

    2003-01-01

    An apparatus that is extremely effective in dispensing a wide range of droplets has been developed. This droplet dispenser is unique in that it utilizes a droplet bias voltage, as well as an ionization pulse, to release a droplet. Apparatuses that deploy individual droplets have been used in many applications, including, notably, study of combustion of liquid fuels. Experiments on isolated droplets are useful in that they enable the study of droplet phenomena under well-controlled and simplified conditions. In this apparatus, a syringe dispenses a known value of liquid, which emerges from, and hangs onto, the outer end of a flat-tipped, stainless steel needle. Somewhat below the needle tip and droplet is a ring electrode. A bias high voltage, followed by a high-voltage pulse, is applied so as to attract the droplet sufficiently to pull it off the needle. The voltages are such that the droplet and needle are negatively charged and the ring electrode is positively charged.

  20. Voltage Weak DC Distribution Grids

    NARCIS (Netherlands)

    Hailu, T.G.; Mackay, L.J.; Ramirez Elizondo, L.M.; Ferreira, J.A.

    2017-01-01

    This paper describes the behavior of voltage weak DC distribution systems. These systems have relatively small system capacitance. The size of system capacitance, which stores energy, has a considerable effect on the value of fault currents, control complexity, and system reliability. A number of

  1. (SPWM) Voltage Source Inverter (VSI)

    African Journals Online (AJOL)

    The quest to achieve less-distorted dc-ac power conversion has resulted in the proliferation of many multilevel inverter configurations. This paper presents an experimental report of a simplified topology for single-phase, SPWM, three-level voltage source inverter wit R-L load. To keep the power circuit component count to a ...

  2. (ann) based dynamic voltage restorer

    African Journals Online (AJOL)

    HOD

    artificial intelligence to provide smart triggering pulses for the DVR to mitigate and to provide compensation against ... the starting of large induction motor [6]. ... ANN-based DVR under voltage sags and swells phenomena. In this case, the ANN is trained off-line, and the trained network is employed for on-line control.

  3. High voltage MOSFET switching circuit

    Science.gov (United States)

    McEwan, Thomas E.

    1994-01-01

    The problem of source lead inductance in a MOSFET switching circuit is compensated for by adding an inductor to the gate circuit. The gate circuit inductor produces an inductive spike which counters the source lead inductive drop to produce a rectangular drive voltage waveform at the internal gate-source terminals of the MOSFET.

  4. Voltage-gated Proton Channels

    Science.gov (United States)

    DeCoursey, Thomas E.

    2014-01-01

    Voltage-gated proton channels, HV1, have vaulted from the realm of the esoteric into the forefront of a central question facing ion channel biophysicists, namely the mechanism by which voltage-dependent gating occurs. This transformation is the result of several factors. Identification of the gene in 2006 revealed that proton channels are homologues of the voltage-sensing domain of most other voltage-gated ion channels. Unique, or at least eccentric, properties of proton channels include dimeric architecture with dual conduction pathways, perfect proton selectivity, a single-channel conductance ~103 smaller than most ion channels, voltage-dependent gating that is strongly modulated by the pH gradient, ΔpH, and potent inhibition by Zn2+ (in many species) but an absence of other potent inhibitors. The recent identification of HV1 in three unicellular marine plankton species has dramatically expanded the phylogenetic family tree. Interest in proton channels in their own right has increased as important physiological roles have been identified in many cells. Proton channels trigger the bioluminescent flash of dinoflagellates, facilitate calcification by coccolithophores, regulate pH-dependent processes in eggs and sperm during fertilization, secrete acid to control the pH of airway fluids, facilitate histamine secretion by basophils, and play a signaling role in facilitating B-cell receptor mediated responses in B lymphocytes. The most elaborate and best-established functions occur in phagocytes, where proton channels optimize the activity of NADPH oxidase, an important producer of reactive oxygen species. Proton efflux mediated by HV1 balances the charge translocated across the membrane by electrons through NADPH oxidase, minimizes changes in cytoplasmic and phagosomal pH, limits osmotic swelling of the phagosome, and provides substrate H+ for the production of H2O2 and HOCl, reactive oxygen species crucial to killing pathogens. PMID:23798303

  5. Compact hyperspectral image sensor based on a novel hyperspectral encoder

    Science.gov (United States)

    Hegyi, Alex N.; Martini, Joerg

    2015-06-01

    A novel hyperspectral imaging sensor is demonstrated that can enable breakthrough applications of hyperspectral imaging in domains not previously accessible. Our technology consists of a planar hyperspectral encoder combined with a traditional monochrome image sensor. The encoder adds negligibly to the sensor's overall size, weight, power requirement, and cost (SWaP-C); therefore, the new imager can be incorporated wherever image sensors are currently used, such as in cell phones and other consumer electronics. In analogy to Fourier spectroscopy, the technique maintains a high optical throughput because narrow-band spectral filters are unnecessary. Unlike conventional Fourier techniques that rely on Michelson interferometry, our hyperspectral encoder is robust to vibration and amenable to planar integration. The device can be viewed within a computational optics paradigm: the hardware is uncomplicated and serves to increase the information content of the acquired data, and the complexity of the system, that is, the decoding of the spectral information, is shifted to computation. Consequently, system tradeoffs, for example, between spectral resolution and imaging speed or spatial resolution, are selectable in software. Our prototype demonstration of the hyperspectral imager is based on a commercially-available silicon CCD. The prototype encoder was inserted within the camera's ~1 cu. in. housing. The prototype can image about 49 independent spectral bands distributed from 350 nm to 1250 nm, but the technology may be extendable over a wavelength range from ~300 nm to ~10 microns, with suitable choice of detector.

  6. Early Decoding and Encoding Strategies.

    Science.gov (United States)

    Goldwater-Rozensher, Susan; Hebard, Amy J.

    A combination of case study observation and mini-experimentation techniques were used to examine a number of issues of relevance in the study of the acquisition of beginning reading skills. Six children were divided equally among three instructional modes: phonics, whole word, and mixed. They were asked to decode and encode words, and their…

  7. Wavelength encoding technique for particle analyses in hematology analyzer

    Science.gov (United States)

    Rongeat, Nelly; Brunel, Patrick; Gineys, Jean-Philippe; Cremien, Didier; Couderc, Vincent; Nérin, Philippe

    2011-07-01

    The aim of this study is to combine multiple excitation wavelengths in order to improve accuracy of fluorescence characterization of labeled cells. The experimental demonstration is realized with a hematology analyzer based on flow cytometry and a CW laser source emitting two visible wavelengths. A given optical encoding associated to each wavelength allows fluorescence identification coming from specific fluorochromes and avoiding the use of noisy compensation method.

  8. The role of optoelectronic feedback on Franz-Keldysh voltage modulation of transistor lasers

    Science.gov (United States)

    Chang, Chi-Hsiang; Chang, Shu-Wei; Wu, Chao-Hsin

    2016-03-01

    Possessing both the high-speed characteristics of heterojunction bipolar transistors (HBTs) and enhanced radiative recombination of quantum wells (QWs), the light-emitting transistor (LET) which operates in the regime of spontaneous emissions has achieved up to 4.3 GHz modulation bandwidth. A 40 Gbit/s transmission rate can be even achieved using transistor laser (TL). The transistor laser provides not only the current modulation but also direct voltage-controlled modulation scheme of optical signals via Franz-Keldysh (FK) photon-assisted tunneling effect. In this work, the effect of FK absorption on the voltage modulation of TLs is investigated. In order to analyze the dynamics and optical responses of voltage modulation in TLs, the conventional rate equations relevant to diode lasers (DLs) are first modified to include the FK effect intuitively. The theoretical results of direct-current (DC) and small-signal alternating-current (AC) characteristics of optical responses are both investigated. While the DC characteristics look physical, the intrinsic optical response of TLs under the FK voltage modulation shows an AC enhancement with a 20 dB peak, which however is not observed in experiment. A complete model composed of the intrinsic optical transfer function and an electrical transfer function fed back by optical responses is proposed to explain the behaviors of voltage modulation in TLs. The abnormal AC peak disappears through this optoelectronic feedback. With the electrical response along with FK-included photon-carrier rate equations taken into account, the complete voltage-controlled optical modulation response of TLs is demonstrated.

  9. Dynamic in situ visualization of voltage-driven magnetic domain evolution in multiferroic heterostructures.

    Science.gov (United States)

    Gao, Ya; Hu, Jia-Mian; Wu, Liang; Nan, C W

    2015-12-23

    Voltage control of magnetism in multiferroic heterostructures provides a promising solution to the excessive heating in spintronic devices. Direct observation of voltage-modulated magnetic domain evolution dynamics is desirable for studying the mechanism of the voltage control of magnetism at mesoscale, but has remained challenging. Here we explored a characterization method for the dynamic in situ evolution of pure voltage modulated magnetic domains in the heterostructures by employing the scanning Kerr microscopy function in the magneto optic Kerr effect system. The local magnetization reorientation of a Ni/PMN-PT heterostructure were characterized under sweeping applied voltage on the PMN-PT single crystal, and the results show that the magnetization rotation angle in the local regions is much greater than that obtained from macroscopic magnetization hysteresis loops.

  10. Over-voltage protection system and method

    Science.gov (United States)

    Chi, Song; Dong, Dong; Lai, Rixin

    2017-05-02

    An over-voltage protection system includes an electronic valve connected across two terminals of a circuit and an over-voltage detection circuit connected across one of the plurality of semiconductor devices for detecting an over-voltage across the circuit. The electronic valve includes a plurality of semiconductor devices connected in series. The over-voltage detection circuit includes a voltage divider circuit connected to a break-over diode in a way to provide a representative low voltage to the break-over diode and an optocoupler configured to receive a current from the break-over diode when the representative low voltage exceeds a threshold voltage of the break-over diode indicating an over-voltage condition. The representative low voltage provided to the break-over diode represents a voltage across the one semiconductor device. A plurality of self-powered gate drive circuits are connected to the plurality of semiconductor devices, wherein the plurality of self-powered gate drive circuits receive over-voltage triggering pulses from the optocoupler during the over-voltage condition and switch on the plurality of semiconductor devices to bypass the circuit.

  11. Compressive Optical Image Encryption

    Science.gov (United States)

    Li, Jun; Sheng Li, Jiao; Yang Pan, Yang; Li, Rong

    2015-01-01

    An optical image encryption technique based on compressive sensing using fully optical means has been proposed. An object image is first encrypted to a white-sense stationary noise pattern using a double random phase encoding (DRPE) method in a Mach-Zehnder interferometer. Then, the encrypted image is highly compressed to a signal using single-pixel compressive holographic imaging in the optical domain. At the receiving terminal, the encrypted image is reconstructed well via compressive sensing theory, and the original image can be decrypted with three reconstructed holograms and the correct keys. The numerical simulations show that the method is effective and suitable for optical image security transmission in future all-optical networks because of the ability of completely optical implementation and substantially smaller hologram data volume. PMID:25992946

  12. Excitability constraints on voltage-gated sodium channels.

    Directory of Open Access Journals (Sweden)

    Elaine Angelino

    2007-09-01

    Full Text Available We study how functional constraints bound and shape evolution through an analysis of mammalian voltage-gated sodium channels. The primary function of sodium channels is to allow the propagation of action potentials. Since Hodgkin and Huxley, mathematical models have suggested that sodium channel properties need to be tightly constrained for an action potential to propagate. There are nine mammalian genes encoding voltage-gated sodium channels, many of which are more than approximately 90% identical by sequence. This sequence similarity presumably corresponds to similarity of function, consistent with the idea that these properties must be tightly constrained. However, the multiplicity of genes encoding sodium channels raises the question: why are there so many? We demonstrate that the simplest theoretical constraints bounding sodium channel diversity--the requirements of membrane excitability and the uniqueness of the resting potential--act directly on constraining sodium channel properties. We compare the predicted constraints with functional data on mammalian sodium channel properties collected from the literature, including 172 different sets of measurements from 40 publications, wild-type and mutant, under a variety of conditions. The data from all channel types, including mutants, obeys the excitability constraint; on the other hand, channels expressed in muscle tend to obey the constraint of a unique resting potential, while channels expressed in neuronal tissue do not. The excitability properties alone distinguish the nine sodium channels into four different groups that are consistent with phylogenetic analysis. Our calculations suggest interpretations for the functional differences between these groups.

  13. Low-Cost Linear Optical Sensors.

    Science.gov (United States)

    Kinsey, Kenneth F.; Meisel, David D.

    1994-01-01

    Discusses the properties and application of three light-to-voltage optical sensors. The sensors have been used for sensing diffraction patterns, the inverse-square law, and as a fringe counter with an interferometer. (MVL)

  14. TRANSISTOR HIGH VOLTAGE POWER SUPPLY

    Science.gov (United States)

    Driver, G.E.

    1958-07-15

    High voltage, direct current power supplies are described for use with battery powered nuclear detection equipment. The particular advantages of the power supply described, are increased efficiency and reduced size and welght brought about by the use of transistors in the circuit. An important feature resides tn the employment of a pair of transistors in an alternatefiring oscillator circuit having a coupling transformer and other circuit components which are used for interconnecting the various electrodes of the transistors.

  15. Advances in high voltage engineering

    CERN Document Server

    Haddad, A

    2005-01-01

    This book addresses the very latest research and development issues in high voltage technology and is intended as a reference source for researchers and students in the field, specifically covering developments throughout the past decade. This unique blend of expert authors and comprehensive subject coverage means that this book is ideally suited as a reference source for engineers and academics in the field for years to come.

  16. VOLTAGE REGULATORS OF SYNCHRONOUS GENERATORS

    OpenAIRE

    Grigorash O. V.; Korzenkov P. G.; Popuchieva M. A.

    2015-01-01

    Synchronous generators are the primary source of electrical power autonomous electrosupply systems, including backup systems. They are also used in a structure of rotating electricity converters and are widely used in renewable energy as part of wind power plants of small, mini and micro hydroelectric plants. Increasing the speed and the accuracy of the system of the voltage regulation of synchronous generators is possible due to the development of combined systems containing more stabilizers...

  17. Low voltage electron beam accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Ochi, Masafumi [Iwasaki Electric Co., Ltd., Tokyo (Japan)

    2003-02-01

    Widely used electron accelerators in industries are the electron beams with acceleration voltage at 300 kV or less. The typical examples are shown on manufactures in Japan, equipment configuration, operation, determination of process parameters, and basic maintenance requirement of the electron beam processors. New electron beam processors with acceleration voltage around 100 kV were introduced maintaining the relatively high dose speed capability of around 10,000 kGy x mpm at production by ESI (Energy Science Inc. USA, Iwasaki Electric Group). The application field like printing and coating for packaging requires treating thickness of 30 micron or less. It does not require high voltage over 110 kV. Also recently developed is a miniature bulb type electron beam tube with energy less than 60 kV. The new application area for this new electron beam tube is being searched. The drive force of this technology to spread in the industries would be further development of new application, process and market as well as the price reduction of the equipment, upon which further acknowledgement and acceptance of the technology to societies and industries would entirely depend. (Y. Tanaka)

  18. Genetically Encoded Fluorescent Redox Probes

    OpenAIRE

    Hui-Wang Ai; Wei Ren

    2013-01-01

    Redox processes are involved in almost every cell of the body as a consequence of aerobic life. In the past decades, redox biology has been increasingly recognized as one of the key themes in cell signaling. The progress has been accelerated by development of fluorescent probes that can monitor redox conditions and dynamics in cells and cell compartments. This short paper focuses on fluorescent redox probes that are genetically encoded, and discusses their properties, molecular mechanism, adv...

  19. VOLTAGE COMPENSATION USING ARTIFICIAL NEURAL NETWORK

    African Journals Online (AJOL)

    A study of hourly voltage log taken over a period of six months from Rumuola Distribution network Port Harcourt, Rivers State indicates that power quality problems prevalent in the Network are undervoltage/voltage sags and overvoltage/voltage swells. This paper aims at addressing these power quality problems in the ...

  20. 49 CFR 234.221 - Lamp voltage.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Lamp voltage. 234.221 Section 234.221 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION..., Inspection, and Testing Maintenance Standards § 234.221 Lamp voltage. The voltage at each lamp shall be...

  1. Linear optics based nanoscopy.

    Science.gov (United States)

    Gur, Aviram; Fixler, Dror; Micó, Vicente; Garcia, Javier; Zalevsky, Zeev

    2010-10-11

    Classically, optical systems are considered to have a fundamental resolution limit due to wave nature of light. This article presents a novel method for observing sub-wavelength features in a conventional optical microscope using linear optics. The operation principle is based on a random and time varying flow of nanoparticles moving in proximity to the inspected sample. Those particles excite the evanescent waves and couple them into harmonic waves. The sub-wavelength features are encoded and later on digitally decoded by proper image processing of a sequence of images. The achievable final resolution limit corresponds to the size of the nanoparticles. Experimental proof of principle validation of the technique is reported.

  2. Enumerative Encoding of TMTR Codes for Optical Recording Channel

    National Research Council Canada - National Science Library

    Tsai, Hui-Feng

    2010-01-01

    We propose a new time-varying maximum transition run (TMTR) code for DVD recording systems, which has a rate higher than the EFMPlus code and a lower power spectral density (PSD) at low frequencies...

  3. 76 FR 70721 - Voltage Coordination on High Voltage Grids; Notice of Staff Workshop

    Science.gov (United States)

    2011-11-15

    ... Energy Regulatory Commission Voltage Coordination on High Voltage Grids; Notice of Staff Workshop Take notice that the Federal Energy Regulatory Commission will hold a Workshop on Voltage Coordination on High Voltage Grids on Thursday, December 1, 2011 from 9 a.m. to 4:30 p.m. This staff-led workshop will be held...

  4. 76 FR 72203 - Voltage Coordination on High Voltage Grids; Notice of Reliability Workshop Agenda

    Science.gov (United States)

    2011-11-22

    ... Energy Regulatory Commission Voltage Coordination on High Voltage Grids; Notice of Reliability Workshop... between voltage control, reliability, and economic dispatch. In addition, the Commission will consider how improvements to dispatch and voltage control software could improve reliability and market efficiency. This...

  5. Optic glioma

    Science.gov (United States)

    Glioma - optic; Optic nerve glioma; Juvenile pilocytic astrocytoma; Brain cancer - optic glioma ... Optic gliomas are rare. The cause of optic gliomas is unknown. Most optic gliomas are slow-growing ...

  6. Improving transition voltage spectroscopy of molecular junctions

    DEFF Research Database (Denmark)

    Markussen, Troels; Chen, Jingzhe; Thygesen, Kristian Sommer

    2011-01-01

    Transition voltage spectroscopy (TVS) is a promising spectroscopic tool for molecular junctions. The principles in TVS is to find the minimum on a Fowler-Nordheim plot where ln(I/V2) is plotted against 1/V and relate the voltage at the minimum Vmin to the closest molecular level. Importantly, Vmin...... is approximately half the voltage required to see a peak in the dI/dV curve. Information about the molecular level position can thus be obtained at relatively low voltages. In this work we show that the molecular level position can be determined at even lower voltages, Vmin(α), by finding the minimum of ln...

  7. A dynamic voltage restorer (DVR) with selective harmonic compensation at medium voltage level

    DEFF Research Database (Denmark)

    Newman, M.J.; Holmes, D.G.; Nielsen, J.G.

    2005-01-01

    Dynamic voltage restorers (DVRs) are now becoming more established in industry to reduce the impact of voltage sags to sensitive loads. However, DVRs spend most of their time in standby mode, since voltage sags occur very infrequently, and hence their utilization is low. In principle, it would...... voltage harmonic compensation capabilities with minimal effect on the sag compensation performance of the basic DVR. The proposed controller has been experimentally verified on a medium-voltage (10 kV) three-phase DVR prototype under a range of conditions, including distorted supply voltages, nonlinear...... loads, and operation during distorted voltage sags....

  8. Low power, scalable multichannel high voltage controller

    Science.gov (United States)

    Stamps, James Frederick [Livermore, CA; Crocker, Robert Ward [Fremont, CA; Yee, Daniel Dadwa [Dublin, CA; Dils, David Wright [Fort Worth, TX

    2008-03-25

    A low voltage control circuit is provided for individually controlling high voltage power provided over bus lines to a multitude of interconnected loads. An example of a load is a drive for capillary channels in a microfluidic system. Control is distributed from a central high voltage circuit, rather than using a number of large expensive central high voltage circuits to enable reducing circuit size and cost. Voltage is distributed to each individual load and controlled using a number of high voltage controller channel switches connected to high voltage bus lines. The channel switches each include complementary pull up and pull down photo isolator relays with photo isolator switching controlled from the central high voltage circuit to provide a desired bus line voltage. Switching of the photo isolator relays is further controlled in each channel switch using feedback from a resistor divider circuit to maintain the bus voltage swing within desired limits. Current sensing is provided using a switched resistive load in each channel switch, with switching of the resistive loads controlled from the central high voltage circuit.

  9. Hall effect encoding of brushless dc motors

    Science.gov (United States)

    Berard, C. A.; Furia, T. J.; Goldberg, E. A.; Greene, R. C.

    1970-01-01

    Encoding mechanism integral to the motor and using the permanent magnets embedded in the rotor eliminates the need for external devices to encode information relating the position and velocity of the rotating member.

  10. Encoding Cortical Dynamics in Sparse Features

    Directory of Open Access Journals (Sweden)

    Sheraz eKhan

    2014-05-01

    Full Text Available Distributed cortical solutions of magnetoencephalography (MEG and electroencephalography (EEG exhibit complex spatial and temporal dynamics. The extraction of patterns of interest and dynamic features from these cortical signals has so far relied on the expertise of investigators. There is a definite need in both clinical and neuroscience research for a method that will extract critical features from high-dimensional neuroimaging data in an automatic fashion. We have previously demonstrated the use of optical flow techniques for evaluating the kinematic properties of motion field projected on non-flat manifolds like in a cortical surface. We have further extended this framework to automatically detect features in the optical flow vector field by using the modified and extended 2-Riemannian Helmholtz Hodge Decomposition (HHD. Here, we applied these mathematical models on simulation and MEG data recorded from a healthy individual during a somatosensory experiment and an epilepsy pediatric patient during sleep. We tested whether our technique can automatically extract salient dynamical features of cortical activity. Simulation results indicated that we can precisely reproduce the simulated cortical dynamics with HHD; encode them in sparse features and represent the propagation of brain activity between distinct cortical areas. Using HHD, we decoded the somatosensory N20 component into two HHD features and represented the dynamics of brain activity as a traveling source between two primary somatosensory regions. In the epilepsy patient, we displayed the propagation of the epileptiform activity around the margins of a brain lesion. Our findings indicate that HHD measures computed from cortical dynamics can: (i quantitatively access the cortical dynamics in both healthy and disease brain in terms of sparse features and dynamic brain activity propagation between distinct cortical areas, and (ii facilitate a reproducible, automated analysis of MEG

  11. Voltage Management in Unbalanced Low Voltage Networks Using a Decoupled Phase-Tap-Changer Transformer

    OpenAIRE

    Coppo, Massimiliano; Turri, Roberto; Marinelli, Mattia; Han, Xue

    2014-01-01

    The paper studies a medium voltage-low voltage transformer with a decoupled on load tap changer capability on each phase. The overall objective is the evaluation of the potential benefits on a low voltage network of such possibility. A realistic Danish low voltage network is used for the analysis. The load profiles are characterized by using single phase measurement data on voltages, currents and active powers with a 10 minutes resolution. Different scenarios are considered: no tap action, th...

  12. Genetically encoded fluorescent redox sensors.

    Science.gov (United States)

    Lukyanov, Konstantin A; Belousov, Vsevolod V

    2014-02-01

    Life is a constant flow of electrons via redox couples. Redox reactions determine many if not all major cellular functions. Until recently, redox processes remained hidden from direct observation in living systems due to the lack of adequate methodology. Over the last years, imaging tools including small molecule probes and genetically encoded sensors appeared, which provided, for the first time, an opportunity to visualize and, in some cases, quantify redox reactions in live cells. Genetically encoded fluorescent redox probes, such as HyPer, rxYFP and roGFPs, have been used in several models, ranging from cultured cells to transgenic animals, and now enough information has been collected to highlight advantages and pitfalls of these probes. In this review, we describe the main types of genetically encoded redox probes, their essential properties, advantages and disadvantages. We also provide an overview of the most important, in our opinion, results obtained using these probes. Finally, we discuss redox-dependent photoconversions of GFP and other prospective directions in redox probe development. Fluorescent protein-based redox probes have important advantages such as high specificity, possibility of transgenesis and fine subcellular targeting. For proper selection of a redox sensor for a particular model, it is important to understand that HyPer and roGFP2-Orp1 are the probes for H2O2, whereas roGFP1/2, rxYFP and roGFP2-Grx1 are the probes for GSH/GSSG redox state. Possible pH changes should be carefully controlled in experiments with HyPer and rxYFP. Genetically encoded redox probes are the only instruments allowing real-time monitoring of reactive oxygen species and thiol redox state in living cells and tissues. We believe that in the near future the palette of FP-based redox probes will be expanded to red and far-red parts of the spectrum and to other important reactive species such as NO, O2 and superoxide. This article is part of a Special Issue entitled

  13. 49 CFR 236.551 - Power supply voltage; requirement.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Power supply voltage; requirement. 236.551 Section... supply voltage; requirement. The voltage of power supply shall be maintained within 10 percent of rated voltage. ...

  14. Ozone Sensor for Application in Medium Voltage Switchboard

    Directory of Open Access Journals (Sweden)

    Letizia De Maria

    2009-01-01

    Full Text Available The application of a new spectroscopic type fiber sensor for ozone detection in electrical components of Medium Voltage (MV network is evaluated. The sensor layout is based on the use of an optical retroreflector, to improve the detection sensitivity, and it was especially designed for detecting in situ rapid changes of ozone concentration. Preliminary tests were performed in a typical MV switchboard. Artificial defects simulated predischarge phenomena arising during real operating conditions. Results are discussed by a comparison with data simultaneously acquired with a standard partial discharge system.

  15. Spatially Fourier-encoded photoacoustic microscopy using a digital micromirror device.

    Science.gov (United States)

    Liang, Jinyang; Gao, Liang; Li, Chiye; Wang, Lihong V

    2014-02-01

    We have developed spatially Fourier-encoded photoacoustic (PA) microscopy using a digital micromirror device. The spatial intensity distribution of laser pulses is Fourier-encoded, and a series of such encoded PA measurements allows one to decode the spatial distribution of optical absorption. The throughput and Fellgett advantages were demonstrated by imaging a chromium target. By using 63 spatial elements, the signal-to-noise ratio in the recovered PA signal was enhanced by ∼4×. The system was used to image two biological targets, a monolayer of red blood cells and melanoma cells.

  16. Power conditioning using dynamic voltage restorers under different voltage sag types

    Directory of Open Access Journals (Sweden)

    Ahmed M. Saeed

    2016-01-01

    Full Text Available Voltage sags can be symmetrical or unsymmetrical depending on the causes of the sag. At the present time, one of the most common procedures for mitigating voltage sags is by the use of dynamic voltage restorers (DVRs. By definition, a DVR is a controlled voltage source inserted between the network and a sensitive load through a booster transformer injecting voltage into the network in order to correct any disturbance affecting a sensitive load voltage. In this paper, modelling of DVR for voltage correction using MatLab software is presented. The performance of the device under different voltage sag types is described, where the voltage sag types are introduced using the different types of short-circuit faults included in the environment of the MatLab/Simulink package. The robustness of the proposed device is evaluated using the common voltage sag indices, while taking into account voltage and current unbalance percentages, where maintaining the total harmonic distortion percentage of the load voltage within a specified range is desired. Finally, several simulation results are shown in order to highlight that the DVR is capable of effective correction of the voltage sag while minimizing the grid voltage unbalance and distortion, regardless of the fault type.

  17. Power conditioning using dynamic voltage restorers under different voltage sag types.

    Science.gov (United States)

    Saeed, Ahmed M; Abdel Aleem, Shady H E; Ibrahim, Ahmed M; Balci, Murat E; El-Zahab, Essam E A

    2016-01-01

    Voltage sags can be symmetrical or unsymmetrical depending on the causes of the sag. At the present time, one of the most common procedures for mitigating voltage sags is by the use of dynamic voltage restorers (DVRs). By definition, a DVR is a controlled voltage source inserted between the network and a sensitive load through a booster transformer injecting voltage into the network in order to correct any disturbance affecting a sensitive load voltage. In this paper, modelling of DVR for voltage correction using MatLab software is presented. The performance of the device under different voltage sag types is described, where the voltage sag types are introduced using the different types of short-circuit faults included in the environment of the MatLab/Simulink package. The robustness of the proposed device is evaluated using the common voltage sag indices, while taking into account voltage and current unbalance percentages, where maintaining the total harmonic distortion percentage of the load voltage within a specified range is desired. Finally, several simulation results are shown in order to highlight that the DVR is capable of effective correction of the voltage sag while minimizing the grid voltage unbalance and distortion, regardless of the fault type.

  18. Pitch-Length Independent Threshold Voltage of Polymer/Cholesteric Liquid Crystal Nano-Composites

    Directory of Open Access Journals (Sweden)

    Hoekyung Kim

    2015-08-01

    Full Text Available Polymer/cholesteric liquid crystal (ChLC nano-composites consisting of mesogenic monomers and LCs have nano-sized LC domains dispersed in an anisotropic polymer matrix. They exhibit characteristics not observed in conventional ChLCs, such as sub-millisecond and “deformation-free” electro-optic tuning of the selective reflection band; however, their driving voltage is high compared to conventional ChLCs, and is an issue that needs to be solved for the practical use. Here, we investigate the helical pitch dependence of threshold voltage in polymer/ChLC nano-composites. Five samples with different helical pitches were prepared and their electro-optic characteristics were compared before and after photopolymerization. Although the threshold voltage of the unpolymerized samples were inversely proportional to its helical pitch, the threshold voltage of the polymerized samples showed no dependence on the helical pitch. These results are explained to be a consequence of the driving mechanism of the polymer/ChLC nano-composite, in which electro-optic switching is achieved as a consequence of the nano-confined LC molecules reorienting along the electric field, instead of the helical structure becoming unwound. The threshold voltage is independent of pitch length because the pore sizes are similar in all samples.

  19. Genes encoding giant danio and golden shiner ependymin.

    Science.gov (United States)

    Adams, D S; Kiyokawa, M; Getman, M E; Shashoua, V E

    1996-03-01

    Ependymin (EPN) is a brain glycoprotein that functions as a neurotrophic factor in optic nerve regeneration and long-term memory consolidation in goldfish. To date, true epn genes have been characterized in one order of teleost fish, Cypriniformes. In the study presented here, polymerase chain reactions were used to analyze the complete epn genes, gd (1480 bp), and sh (2071 bp), from Cypriniformes giant danio and shiner, respectively. Southern hybridizations demonstrated the existence of one copy of each gene per corresponding haploid genome. Each gene was found to contain six exons and five introns. Gene gd encodes a predicted 218-amino acid (aa) protein GD 93 percent conserved to goldfish EPN, while sh encodes a predicted 214-aa protein SH 91 percent homologous to goldfish. Evidence is presented classifying proteins previously termed "EPNs" into two major categories: true EPNs and non-EPN cerebrospinal fluid glycoproteins. Proteins GD and SH contain all the hallmark, features of true EPNs.

  20. Cloning and sequencing the genes encoding goldfish and carp ependymin.

    Science.gov (United States)

    Adams, D S; Shashoua, V E

    1994-04-20

    Ependymins (EPNs) are brain glycoproteins thought to function in optic nerve regeneration and long-term memory consolidation. To date, epn genes have been characterized in two orders of teleost fish. In this study, polymerase chain reactions (PCR) were used to amplify the complete 1.6-kb epn genes, gf-I and cc-I, from genomic DNA of Cypriniformes, goldfish and carp, respectively. Amplified bands were cloned and sequenced. Each gene consists of six exons and five introns. The exon portion of gf-I encodes a predicted 215-amino-acid (aa) protein previously characterized as GF-I, while cc-I encodes a predicted 215-aa protein 95% homologous to GF-I.

  1. Mapping of voltage sensor positions in resting and inactivated mammalian sodium channels by LRET.

    Science.gov (United States)

    Kubota, Tomoya; Durek, Thomas; Dang, Bobo; Finol-Urdaneta, Rocio K; Craik, David J; Kent, Stephen B H; French, Robert J; Bezanilla, Francisco; Correa, Ana M

    2017-03-07

    Voltage-gated sodium channels (Navs) play crucial roles in excitable cells. Although vertebrate Nav function has been extensively studied, the detailed structural basis for voltage-dependent gating mechanisms remain obscure. We have assessed the structural changes of the Nav voltage sensor domain using lanthanide-based resonance energy transfer (LRET) between the rat skeletal muscle voltage-gated sodium channel (Nav1.4) and fluorescently labeled Nav1.4-targeting toxins. We generated donor constructs with genetically encoded lanthanide-binding tags (LBTs) inserted at the extracellular end of the S4 segment of each domain (with a single LBT per construct). Three different Bodipy-labeled, Nav1.4-targeting toxins were synthesized as acceptors: β-scorpion toxin (Ts1)-Bodipy, KIIIA-Bodipy, and GIIIA-Bodipy analogs. Functional Nav-LBT channels expressed in Xenopus oocytes were voltage-clamped, and distinct LRET signals were obtained in the resting and slow inactivated states. Intramolecular distances computed from the LRET signals define a geometrical map of Nav1.4 with the bound toxins, and reveal voltage-dependent structural changes related to channel gating.

  2. Molecular mechanisms for protein-encoded inheritance

    Energy Technology Data Exchange (ETDEWEB)

    Wiltzius, Jed J.W.; Landau, Meytal; Nelson, Rebecca; Sawaya, Michael R.; Apostol, Marcin I.; Goldschmidt, Lukasz; Soriaga, Angela B.; Cascio, Duilio; Rajashankar, Kanagalaghatta; Eisenberg, David; (Cornell); (HHMI)

    2009-12-01

    In prion inheritance and transmission, strains are phenotypic variants encoded by protein 'conformations'. However, it is unclear how a protein conformation can be stable enough to endure transmission between cells or organisms. Here we describe new polymorphic crystal structures of segments of prion and other amyloid proteins, which offer two structural mechanisms for the encoding of prion strains. In packing polymorphism, prion strains are encoded by alternative packing arrangements (polymorphs) of {beta}-sheets formed by the same segment of a protein; in segmental polymorphism, prion strains are encoded by distinct {beta}-sheets built from different segments of a protein. Both forms of polymorphism can produce enduring conformations capable of encoding strains. These molecular mechanisms for transfer of protein-encoded information into prion strains share features with the familiar mechanism for transfer of nucleic acid-encoded information into microbial strains, including sequence specificity and recognition by noncovalent bonds.

  3. Annotation of functional impact of voltage?gated sodium channel mutations

    OpenAIRE

    Hinard, Valérie; Britan, Aurore; Schaeffer, Mathieu; Zahn, Monique; Thomet, Urs; Rougier, Jean-Sébastien; Bairoch, Amos Marc; Abriel, Hugues; Gaudet, Pascale

    2017-01-01

    Abstract Voltage?gated sodium channels are pore?forming transmembrane proteins that selectively allow sodium ions to flow across the plasma membrane according to the electro?chemical gradient thus mediating the rising phase of action potentials in excitable cells and playing key roles in physiological processes such as neurotransmission, skeletal muscle contraction, heart rhythm, and pain sensation. Genetic variations in the nine human genes encoding these channels are known to cause a large ...

  4. Dynamical encoding of cursive handwriting.

    Science.gov (United States)

    Singer, Y; Tishby, N

    1994-01-01

    A model-based approach to on-line cursive handwriting analysis and recognition is presented and evaluated. In this model, on-line handwriting is considered as a modulation of a simple cycloidal pen motion, described by two coupled oscillations with a constant linear drift along the line of the writing. By slow modulations of the amplitudes and phase lags of the two oscillators, a general pen trajectory can be efficiently encoded. These parameters are then quantized into a small number of values without altering the writing intelligibility. A general procedure for the estimation and quantization of these cycloidal motion parameters for arbitrary handwriting is presented. The result is a discrete motor control representation of the continuous pen motion, via the quantized levels of the model parameters. This motor control representation enables successful word spotting and matching of cursive scripts. Our experiments clearly indicate the potential of this dynamic representation for complete cursive handwriting recognition.

  5. Engineering Genetically Encoded FRET Sensors

    Science.gov (United States)

    Lindenburg, Laurens; Merkx, Maarten

    2014-01-01

    Förster Resonance Energy Transfer (FRET) between two fluorescent proteins can be exploited to create fully genetically encoded and thus subcellularly targetable sensors. FRET sensors report changes in energy transfer between a donor and an acceptor fluorescent protein that occur when an attached sensor domain undergoes a change in conformation in response to ligand binding. The design of sensitive FRET sensors remains challenging as there are few generally applicable design rules and each sensor must be optimized anew. In this review we discuss various strategies that address this shortcoming, including rational design approaches that exploit self-associating fluorescent domains and the directed evolution of FRET sensors using high-throughput screening. PMID:24991940

  6. Silicone elastomers with aromatic voltage stabilizers

    DEFF Research Database (Denmark)

    A Razak, Aliff Hisyam; Skov, Anne Ladegaard

    elastomers with high relative permittivity and low Young’s modulus in order to increase the actuation performance at a given voltage, but the optimised elastomers often possess relatively low electrical breakdown strength. On the other hand, increasing the electrical breakdown strength of DEs allows...... modifications. In order to increase the electrical breakdown strength of polymers for e.g. the cable industry, additives like aromatic voltage stabilizers are used. Earlier works on using voltage stabilizers in polymers have mainly focused on polyethylene with the purpose of reducing power loss for high voltage...... insulation cables.3–5 As an alternative to utilise additives as voltage stabilizers, grafting aromatic compounds to silicone backbones may overcome the common problem of insolubility of the aromatic voltage stabilizer in the silicone elastomers due to phase separation. Preventing phase separation during...

  7. Voltage-Controlled Floating Resistor Using DDCC

    Directory of Open Access Journals (Sweden)

    M. Kumngern

    2011-04-01

    Full Text Available This paper presents a new simple configuration to realize the voltage-controlled floating resistor, which is suitable for integrated circuit implementation. The proposed resistor is composed of three main components: MOS transistor operating in the non-saturation region, DDCC, and MOS voltage divider. The MOS transistor operating in the non-saturation region is used to configure a floating linear resistor. The DDCC and the MOS transistor voltage divider are used for canceling the nonlinear component term of MOS transistor in the non-saturation region to obtain a linear current/voltage relationship. The DDCC is employed to provide a simple summer of the circuit. This circuit offers an ease for realizing the voltage divider circuit and the temperature effect that includes in term of threshold voltage can be compensated. The proposed configuration employs only 16 MOS transistors. The performances of the proposed circuit are simulated with PSPICE to confirm the presented theory.

  8. Electrochemical Design of Optical Nanoantennas

    Directory of Open Access Journals (Sweden)

    Vasilchenko V.E.

    2015-01-01

    Full Text Available Electrochemical techniques for fabricating tapered gold nanoantennas (tips are discussed. In the paper, the tunable design of nanoantennas is demonstrated. Tip parameters such as a tip apex curvature, mesoscopic morphology, aspect ratio and enhancement factor can be varied with etching electrolyte and applied voltage. The low-cost method makes tipehnahced optical spectroscopy and microscopy feasible for routine optical measurements beyond the diffraction limit.

  9. Optic neuritis

    Science.gov (United States)

    Retro-bulbar neuritis; Multiple sclerosis - optic neuritis; Optic nerve - optic neuritis ... The exact cause of optic neuritis is unknown. The optic nerve carries visual information from your eye to the brain. The nerve can swell when ...

  10. High-voltage power supply unit

    CERN Document Server

    Garipov, G K; Silaev, A A; Shirokov, A V

    2002-01-01

    A unit comprising four high-voltage power sources (HPS) is designed for power supply of four independent photomultipliers. Each HPS comprises a pulse-width modulator, digital-to-analog converter, base voltage source and digital interface. HPS unit supplies up to 2000 V output voltage, up to 2.5 mA current and long-term stability equal to +- 0.03%

  11. A high voltage, constant current stimulator for electrocutaneous stimulation through small electrodes.

    Science.gov (United States)

    Poletto, C J; Van Doren, C L

    1999-08-01

    A high-voltage stimulator has been designed to allow transcutaneous stimulation of tactile fibers of the fingertip. The stimulator's output stage was based upon an improved Howland current pump topology, modified to allow high load impedances and small currents. The compliance voltage of approximately 800 V is achieved using commercially available high-voltage operational amplifiers. The output current accuracy is better than +/- 5% over the range of 1 to 25 mA for 30 microseconds or longer pulses. The rise time for square pulses is less than 1 microsecond. High-voltage, common-mode, latch-up power supply problems and solutions are discussed. The stimulator's input stage is optically coupled to the controlling computer and complies with applicable safety standards for use in a hospital environment. The design presented here is for monophasic stimulation only, but could be modified for biphasic stimulation.

  12. Design of 4 to 2 line encoder using lithium niobate based Mach Zehnder Interferometers for high speed communication

    Science.gov (United States)

    Pal, Amrindra; Kumar, Santosh; Sharma, Sandeep; Raghuwanshi, Sanjeev K.

    2016-04-01

    Encoder is a device that allows placing digital information from many inputs to many outputs. Any application of combinational logic circuit can be implemented by using encoder and external gates. In this paper, 4 to 2 line encoder is proposed using electro-optic effect inside lithium-niobate based Mach-Zehnder interferometers (MZIs). The MZI structures have powerful capability to switching an optical input signal to a desired output port. The paper constitutes a mathematical description of the proposed device and thereafter simulation using MATLAB. The study is verified using beam propagation method (BPM).

  13. Technical feasibility study of Voltage Optimization Unit

    DEFF Research Database (Denmark)

    Hu, Junjie; Marinelli, Mattia; Coppo, Massimiliano

    is performed using the soft-wares DigSilent PowerFactory and Matlab. In this simulation study, a real low voltage network from Dong Eldistribution is modeled in Powerfactory. The measured data of the real low voltage network is analyzed and the resulting loading profiles including active and reactive power...... are used as load basics for the analysis. In term of PV genera-tion profiles, a realistic PV output power is assumed. Four relevant indicies such as phase neutral voltage, netural potential voltage, unbalanced factor (VUF), and power losses are evaluated in the present study. The simulation tests include...

  14. SnoVault and encodeD: A novel object-based storage system and applications to ENCODE metadata.

    Science.gov (United States)

    Hitz, Benjamin C; Rowe, Laurence D; Podduturi, Nikhil R; Glick, David I; Baymuradov, Ulugbek K; Malladi, Venkat S; Chan, Esther T; Davidson, Jean M; Gabdank, Idan; Narayana, Aditi K; Onate, Kathrina C; Hilton, Jason; Ho, Marcus C; Lee, Brian T; Miyasato, Stuart R; Dreszer, Timothy R; Sloan, Cricket A; Strattan, J Seth; Tanaka, Forrest Y; Hong, Eurie L; Cherry, J Michael

    2017-01-01

    The Encyclopedia of DNA elements (ENCODE) project is an ongoing collaborative effort to create a comprehensive catalog of functional elements initiated shortly after the completion of the Human Genome Project. The current database exceeds 6500 experiments across more than 450 cell lines and tissues using a wide array of experimental techniques to study the chromatin structure, regulatory and transcriptional landscape of the H. sapiens and M. musculus genomes. All ENCODE experimental data, metadata, and associated computational analyses are submitted to the ENCODE Data Coordination Center (DCC) for validation, tracking, storage, unified processing, and distribution to community resources and the scientific community. As the volume of data increases, the identification and organization of experimental details becomes increasingly intricate and demands careful curation. The ENCODE DCC has created a general purpose software system, known as SnoVault, that supports metadata and file submission, a database used for metadata storage, web pages for displaying the metadata and a robust API for querying the metadata. The software is fully open-source, code and installation instructions can be found at: http://github.com/ENCODE-DCC/snovault/ (for the generic database) and http://github.com/ENCODE-DCC/encoded/ to store genomic data in the manner of ENCODE. The core database engine, SnoVault (which is completely independent of ENCODE, genomic data, or bioinformatic data) has been released as a separate Python package.

  15. SGK3 Sensitivity of Voltage Gated K+ Channel Kv1.5 (KCNA5

    Directory of Open Access Journals (Sweden)

    Musaab Ahmed

    2016-01-01

    Full Text Available Background: The serum & glucocorticoid inducible kinase isoform SGK3 is a powerful regulator of several transporters, ion channels and the Na+/K+ ATPase. Targets of SGK3 include the ubiquitin ligase Nedd4-2, which is in turn a known regulator of the voltage gated K+ channel Kv1.5 (KCNA5. The present study thus explored whether SGK3 modifies the activity of the voltage gated K+ channel KCNA5, which participates in the regulation of diverse functions including atrial cardiac action potential, activity of vascular smooth muscle cells, insulin release and tumour cell proliferation. Methods: cRNA encoding KCNA5 was injected into Xenopus oocytes with and without additional injection of cRNA encoding wild-type SGK3, constitutively active S419DSGK3, inactive K191NSGK3 and/or wild type Nedd4-2. Voltage gated K+ channel activity was quantified utilizing dual electrode voltage clamp. Results: Voltage gated current in KCNA5 expressing Xenopus oocytes was significantly enhanced by wild-type SGK3 and S419DSGK3, but not by K191NSGK3. SGK3 was effective in the presence of ouabain (1 mM and thus did not require Na+/K+ ATPase activity. Coexpression of Nedd4-2 decreased the voltage gated current in KCNA5 expressing Xenopus oocytes, an effect largely reversed by additional coexpression of SGK3. Conclusion: SGK3 is a positive regulator of KCNA5, which is at least partially effective by abrogating the effect of Nedd4-2.

  16. Excitation of voltage oscillations in an induction voltage adder

    Directory of Open Access Journals (Sweden)

    Nichelle Bruner

    2009-07-01

    Full Text Available The induction voltage adder is an accelerator architecture used in recent designs of pulsed-power driven x-ray radiographic systems such as Sandia National Laboratories’ Radiographic Integrated Test Stand (RITS, the Atomic Weapons Establishment’s planned Hydrus Facility, and the Naval Research Laboratory’s Mercury. Each of these designs relies on magnetic insulation to prevent electron loss across the anode-cathode gap in the vicinity of the adder as well as in the coaxial transmission line. Particle-in-cell simulations of the RITS adder and transmission line show that, as magnetic insulation is being established during a pulse, some electron loss occurs across the gap. Sufficient delay in the cavity pulse timings provides an opportunity for high-momentum electrons to deeply penetrate the cavities of the adder cells where they can excite radio-frequency resonances. These oscillations may be amplified in subsequent gaps, resulting in oscillations in the output power. The specific modes supported by the RITS-6 accelerator and details of the mechanism by which they are excited are presented in this paper.

  17. Enhancement of AC high voltage measurements’ uncertainty using a high voltage divider calibration method

    Directory of Open Access Journals (Sweden)

    El-Rifaie Ali M.

    2015-01-01

    Full Text Available This paper discusses enhancing of the measurements’ uncertainty for AC high voltage up to 100 kV. This is achieved by using a high voltage divider calibration method. Voltage measurements have been carried out at the Egyptian national institute for standards (NIS, using a high voltage measuring system (Phenix-KVM100, that consists of a high voltage divider and a voltage display. The voltage divider and display have been calibrated in low and high voltage ranges. Reference standard digital voltmeter and a multifunction calibrator have been used to calibrate the KVM100 for achieving accurate and traceable results. All calibrations have been performed automatically using Laboratory Virtual Instrument Engineering Workbench (LabVIEW programs specially designed for this task. Uncertainty budget has been evaluated to get the measurements’ expanded uncertainties.

  18. Fiber optic data transmission

    Science.gov (United States)

    Shreve, Steven T.

    1987-01-01

    The Ohio University Avionics Engineering Center is currently developing a fiber optic data bus transmission and reception system that could eventually replace copper cable connections in airplanes. The original form of the system will transmit information from an encoder to a transponder via a fiber optic cable. An altimeter and an altitude display are connected to a fiber optic transmitter by copper cable. The transmitter converts the altimetry data from nine bit parallel to serial form and send these data through a fiber optic cable to a receiver. The receiver converts the data using a cable similar to that used between the altimeter and display. The transmitting and receiving ends also include a display readout. After completion and ground testing of the data bus, the system will be tested in an airborne environment.

  19. Plasmon Enhanced Optical Near-field Probing of Metal Nanoaperture Surface Emitting Laser

    National Research Council Canada - National Science Library

    Jiro Hashizume; Fumio Koyama

    2004-01-01

    ...) for sub-wavelength optical near-filed probing, which exhibits the strong plasmon enhancement of both optical near-fields and voltage signals with forming a metal nano-particle in the nano-aperture...

  20. Evaluation of the Voltage Support Strategies for the Low Voltage Grid Connected PV

    DEFF Research Database (Denmark)

    Demirok, Erhan; Sera, Dezso; Teodorescu, Remus

    2010-01-01

    Admissible range of grid voltage is one of the strictest constraints for the penetration of distributed photovoltaic (PV) generators especially connection to low voltage (LV) public networks. Voltage limits are usually fulfilled either by network reinforcements or limiting of power injections fro...

  1. Voltage-Sensitive Load Controllers for Voltage Regulation and Increased Load Factor in Distribution Systems

    DEFF Research Database (Denmark)

    Douglass, Philip James; Garcia-Valle, Rodrigo; Østergaard, Jacob

    2014-01-01

    This paper presents a novel controller design for controlling appliances based on local measurements of voltage. The controller finds the normalized voltage deviation accounting for the sensitivity of voltage measurements to appliance state. The controller produces a signal indicating desired pow...

  2. Voltage stability in low voltage microgrids in aspects of active and reactive power demand

    Directory of Open Access Journals (Sweden)

    Parol Mirosław

    2016-03-01

    Full Text Available Low voltage microgrids are autonomous subsystems, in which generation, storage and power and electrical energy consumption appear. In the paper the main attention has been paid to the voltage stability issue in low voltage microgrid for different variants of its operation. In the introduction a notion of microgrid has been presented, and also the issue of influence of active and reactive power balance on node voltage level has been described. Then description of voltage stability issue has been presented. The conditions of voltage stability and indicators used to determine voltage stability margin in the microgrid have been described. Description of the low voltage test microgrid, as well as research methodology along with definition of considered variants of its operation have been presented further. The results of exemplary calculations carried out for the daily changes in node load of the active and reactive power, i.e. the voltage and the voltage stability margin indexes in nodes have been presented. Furthermore, the changes of voltage stability margin indexes depending on the variant of the microgrid operation have been presented. Summary and formulation of conclusions related to the issue of voltage stability in microgrids have been included at the end of the paper.

  3. System for verification in situ of current transformers in high voltage substations; Sistema para verificacao in situ de transformadores de corrente em substacoes de alta tensao

    Energy Technology Data Exchange (ETDEWEB)

    Mendonca, Pedro Henrique; Costa, Marcelo M. da; Dahlke, Diogo B.; Ikeda, Minoru [LACTEC - Instituto de Tecnologia para o Desenvolvimento, Curitiba, PR (Brazil)], Emails: pedro.henrique@lactec.org.br, arinos@lactec.org.br, diogo@lactec.org.br, minoru@lactec.org.br, Celso.melo@copel.com; Carvalho, Joao Claudio D. de [ELETRONORTE, Belem, PR (Brazil)], E-mail: marcelo.melo@eln.gov.br; Teixeira Junior, Jose Arinos [ELETROSUL, Florianopolis, SC (Brazil)], E-mail: jclaudio@eletrosul.gov.br; Melo, Celso F. [Companhia Paranaense de Energia (COPEL), Curitiba, PR (Brazil)], E-mail: Celso.melo@copel.com

    2009-07-01

    This work presents an alternative proposal to the execute the calibration of conventional current transformer at the field, using a verification system composed by a optical current transformer as a reference standard, able to installation in extra high voltage bars.

  4. Novelty's effect on memory encoding.

    Science.gov (United States)

    Rangel-Gomez, Mauricio; Janenaite, Sigita; Meeter, Martijn

    2015-07-01

    It is often thought that novelty benefits memory formation. However, support for this idea mostly comes from paradigms that are open to alternative explanations. In the present study we manipulated novelty in a word-learning task through task-irrelevant background images. These background images were either standard (presented repeatedly), or novel (presented only once). Two types of background images were used: Landscape pictures and fractals. EEG was also recorded during encoding. Contrary to the idea that novelty aids memory formation, memory performance was not affected by the novelty of the background. In the evoked response potentials, we found evidence of distracting effects of novelty: both the N1 and P3b components were smaller to words studied with novel backgrounds, and the amplitude of the N2b component correlated negatively with subsequent retrieval. We conclude that although evidence from other studies does suggest benefits on a longer time scale, novelty has no instantaneous benefits for learning. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Background-free balanced optical cross correlator

    Science.gov (United States)

    Nejadmalayeri, Amir Hossein; Kaertner, Franz X

    2014-12-23

    A balanced optical cross correlator includes an optical waveguide, a first photodiode including a first n-type semiconductor and a first p-type semiconductor positioned about the optical waveguide on a first side of the optical waveguide's point of symmetry, and a second photodiode including a second n-type semiconductor and a second p-type semiconductor positioned about the optical waveguide on a second side of the optical waveguide's point of symmetry. A balanced receiver including first and second inputs is configured to produce an output current or voltage that reflects a difference in currents or voltages, originating from the first and the second photodiodes of the balanced cross correlator and fed to the first input and to the second input of the balanced receiver.

  6. High-voltage engineering and testing

    CERN Document Server

    Ryan, Hugh M

    2013-01-01

    This 3rd edition of High Voltage Engineering Testing describes strategic developments in the field and reflects on how they can best be managed. All the key components of high voltage and distribution systems are covered including electric power networks, UHV and HV. Distribution systems including HVDC and power electronic systems are also considered.

  7. Reduced Voltage Scaling in Clock Distribution Networks

    Directory of Open Access Journals (Sweden)

    Khader Mohammad

    2009-01-01

    Full Text Available We propose a novel circuit technique to generate a reduced voltage swing (RVS signals for active power reduction on main buses and clocks. This is achieved without performance degradation, without extra power supply requirement, and with minimum area overhead. The technique stops the discharge path on the net that is swinging low at a certain voltage value. It reduces active power on the target net by as much as 33% compared to traditional full swing signaling. The logic 0 voltage value is programmable through control bits. If desired, the reduced-swing mode can also be disabled. The approach assumes that the logic 0 voltage value is always less than the threshold voltage of the nMOS receivers, which eliminate the need of the low to high voltage translation. The reduced noise margin and the increased leakage on the receiver transistors using this approach have been addressed through the selective usage of multithreshold voltage (MTV devices and the programmability of the low voltage value.

  8. Modeling and Simulation of Low Voltage Arcs

    NARCIS (Netherlands)

    Ghezzi, L.; Balestrero, A.

    2010-01-01

    Modeling and Simulation of Low Voltage Arcs is an attempt to improve the physical understanding, mathematical modeling and numerical simulation of the electric arcs that are found during current interruptions in low voltage circuit breakers. An empirical description is gained by refined electrical

  9. Low-Voltage Continuous Electrospinning Patterning.

    Science.gov (United States)

    Li, Xia; Li, Zhaoying; Wang, Liyun; Ma, Guokun; Meng, Fanlong; Pritchard, Robyn H; Gill, Elisabeth L; Liu, Ye; Huang, Yan Yan Shery

    2016-11-30

    Electrospinning is a versatile technique for the construction of microfibrous and nanofibrous structures with considerable potential in applications ranging from textile manufacturing to tissue engineering scaffolds. In the simplest form, electrospinning uses a high voltage of tens of thousands volts to draw out ultrafine polymer fibers over a large distance. However, the high voltage limits the flexible combination of material selection, deposition substrate, and control of patterns. Prior studies show that by performing electrospinning with a well-defined "near-field" condition, the operation voltage can be decreased to the kilovolt range, and further enable more precise patterning of fibril structures on a planar surface. In this work, by using solution dependent "initiators", we demonstrate a further lowering of voltage with an ultralow voltage continuous electrospinning patterning (LEP) technique, which reduces the applied voltage threshold to as low as 50 V, simultaneously permitting direct fiber patterning. The versatility of LEP is shown using a wide range of combination of polymer and solvent systems for thermoplastics and biopolymers. Novel functionalities are also incorporated when a low voltage mode is used in place of a high voltage mode, such as direct printing of living bacteria; the construction of suspended single fibers and membrane networks. The LEP technique reported here should open up new avenues in the patterning of bioelements and free-form nano- to microscale fibrous structures.

  10. Inhibition of voltage-gated sodium channels by sumatriptan bioisosteres

    Directory of Open Access Journals (Sweden)

    Roberta eCarbonara

    2015-07-01

    Full Text Available Voltage-gated sodium channels are known to play a pivotal role in perception and transmission of pain sensations. Gain-of-function mutations in the genes encoding the peripheral neuronal sodium channels, hNav1.7-1.9, cause human painful diseases. Thus while treatment of chronic pain remains an unmet clinical need, sodium channel blockers are considered as promising druggable targets. In a previous study, we evaluated the analgesic activity of sumatriptan, an agonist of serotonin 5HT1B/D receptors, and some new chiral bioisosteres, using the hot plate test in the mouse. Interestingly, we observed that the analgesic effectiveness was not necessarily correlated to serotonin agonism. In this study, we evaluated whether sumatriptan and its congeners may inhibit heterologously-expressed hNav1.7 sodium channels using the patch-clamp method. We show that sumatriptan blocks hNav1.7 channels only at very high, supratherapeutic concentrations. In contrast, its three analogues, namely 20b, (R-31b, and (S-22b, exert a dose and use-dependent sodium channel block. At 0.1 and 10 Hz stimulation frequencies, the most potent compound, (S-22b, was 4.4 and 1.7 fold more potent than the well-known sodium channel blocker mexiletine. The compound induces a negative shift of voltage dependence of fast inactivation, suggesting higher affinity to the inactivated channel. Accordingly, we show that (S-22b likely binds the conserved local anesthetic receptor within voltage-gated sodium channels. Combining these results with the previous ones, we hypothesize that use-dependent sodium channel blockade contributes to the analgesic activity of (R-31b and (S-22b. These later compounds represent promising lead compounds for the development of efficient analgesics, the mechanism of action of which may include a dual action on sodium channels and 5HT1D receptors.

  11. Inhibition of voltage-gated sodium channels by sumatriptan bioisosteres.

    Science.gov (United States)

    Carbonara, Roberta; Carocci, Alessia; Roussel, Julien; Crescenzo, Giuseppe; Buonavoglia, Canio; Franchini, Carlo; Lentini, Giovanni; Camerino, Diana Conte; Desaphy, Jean-François

    2015-01-01

    Voltage-gated sodium channels are known to play a pivotal role in perception and transmission of pain sensations. Gain-of-function mutations in the genes encoding the peripheral neuronal sodium channels, hNav1.7-1.9, cause human painful diseases. Thus while treatment of chronic pain remains an unmet clinical need, sodium channel blockers are considered as promising druggable targets. In a previous study, we evaluated the analgesic activity of sumatriptan, an agonist of serotonin 5HT1B/D receptors, and some new chiral bioisosteres, using the hot plate test in the mouse. Interestingly, we observed that the analgesic effectiveness was not necessarily correlated to serotonin agonism. In this study, we evaluated whether sumatriptan and its congeners may inhibit heterologously expressed hNav1.7 sodium channels using the patch-clamp method. We show that sumatriptan blocks hNav1.7 channels only at very high, supratherapeutic concentrations. In contrast, its three analogs, namely 20b, (R)-31b, and (S)-22b, exert a dose and use-dependent sodium channel block. At 0.1 and 10 Hz stimulation frequencies, the most potent compound, (S)-22b, was 4.4 and 1.7 fold more potent than the well-known sodium channel blocker mexiletine. The compound induces a negative shift of voltage dependence of fast inactivation, suggesting higher affinity to the inactivated channel. Accordingly, we show that (S)-22b likely binds the conserved local anesthetic receptor within voltage-gated sodium channels. Combining these results with the previous ones, we hypothesize that use-dependent sodium channel blockade contributes to the analgesic activity of (R)-31b and (S)-22b. These later compounds represent promising lead compounds for the development of efficient analgesics, the mechanism of action of which may include a dual action on sodium channels and 5HT1D receptors.

  12. Voltage-gated lipid ion channels

    DEFF Research Database (Denmark)

    Blicher, Andreas; Heimburg, Thomas Rainer

    2013-01-01

    probability as a function of voltage. The voltage-dependence of the lipid pores is found comparable to that of protein channels. Lifetime distributions of open and closed events indicate that the channel open distribution does not follow exponential statistics but rather power law behavior for long open times......Synthetic lipid membranes can display channel-like ion conduction events even in the absence of proteins. We show here that these events are voltage-gated with a quadratic voltage dependence as expected from electrostatic theory of capacitors. To this end, we recorded channel traces and current...... histograms in patch-experiments on lipid membranes. We derived a theoretical current-voltage relationship for pores in lipid membranes that describes the experimental data very well when assuming an asymmetric membrane. We determined the equilibrium constant between closed and open state and the open...

  13. Coordinated Voltage Control of Active Distribution Network

    Directory of Open Access Journals (Sweden)

    Xie Jiang

    2016-01-01

    Full Text Available This paper presents a centralized coordinated voltage control method for active distribution network to solve off-limit problem of voltage after incorporation of distributed generation (DG. The proposed method consists of two parts, it coordinated primal-dual interior point method-based voltage regulation schemes of DG reactive powers and capacitors with centralized on-load tap changer (OLTC controlling method which utilizes system’s maximum and minimum voltages, to improve the qualified rate of voltage and reduce the operation numbers of OLTC. The proposed coordination has considered the cost of capacitors. The method is tested using a radial edited IEEE-33 nodes distribution network which is modelled using MATLAB.

  14. Non-contact current and voltage sensor

    Science.gov (United States)

    Carpenter, Gary D; El-Essawy, Wael; Ferreira, Alexandre Peixoto; Keller, Thomas Walter; Rubio, Juan C; Schappert, Michael A

    2014-03-25

    A detachable current and voltage sensor provides an isolated and convenient device to measure current passing through a conductor such as an AC branch circuit wire, as well as providing an indication of an electrostatic potential on the wire, which can be used to indicate the phase of the voltage on the wire, and optionally a magnitude of the voltage. The device includes a housing that contains the current and voltage sensors, which may be a ferrite cylinder with a hall effect sensor disposed in a gap along the circumference to measure current, or alternative a winding provided through the cylinder along its axis and a capacitive plate or wire disposed adjacent to, or within, the ferrite cylinder to provide the indication of the voltage.

  15. Practical considerations in voltage stability assessment

    Energy Technology Data Exchange (ETDEWEB)

    Kundur, P.; Gao, B. [Powertech Labs. Inc., Surrey, BC (Canada)

    1994-12-31

    This paper deals with some of the most important practical issues related to voltage stability assessment of large practical systems. A brief discussion of the practical aspects of voltage stability problem and prevention of voltage instability is given first, followed by descriptions of different analytical techniques and tools for voltage stability analysis. Presentations of analytical tools is focused on the VSTAB program which incorporates the modal analysis, continuation power flow, and shortest distance to instability techniques, Finally, an example case study of a practical large system is presented. The case study illustrates how modal analysis is used to determine the most effective load shedding scheme for preventing voltage instability. (author) 15 refs., 2 figs., 2 tabs.

  16. Hysteresis in voltage-gated channels.

    Science.gov (United States)

    Villalba-Galea, Carlos A

    2017-03-04

    Ion channels constitute a superfamily of membrane proteins found in all living creatures. Their activity allows fast translocation of ions across the plasma membrane down the ion's transmembrane electrochemical gradient, resulting in a difference in electrical potential across the plasma membrane, known as the membrane potential. A group within this superfamily, namely voltage-gated channels, displays activity that is sensitive to the membrane potential. The activity of voltage-gated channels is controlled by the membrane potential, while the membrane potential is changed by these channels' activity. This interplay produces variations in the membrane potential that have evolved into electrical signals in many organisms. These signals are essential for numerous biological processes, including neuronal activity, insulin release, muscle contraction, fertilization and many others. In recent years, the activity of the voltage-gated channels has been observed not to follow a simple relationship with the membrane potential. Instead, it has been shown that the activity of voltage-gated channel displays hysteresis. In fact, a growing number of evidence have demonstrated that the voltage dependence of channel activity is dynamically modulated by activity itself. In spite of the great impact that this property can have on electrical signaling, hysteresis in voltage-gated channels is often overlooked. Addressing this issue, this review provides examples of voltage-gated ion channels displaying hysteretic behavior. Further, this review will discuss how Dynamic Voltage Dependence in voltage-gated channels can have a physiological role in electrical signaling. Furthermore, this review will elaborate on the current thoughts on the mechanism underlying hysteresis in voltage-gated channels.

  17. Voltage Management in Unbalanced Low Voltage Networks Using a Decoupled Phase-Tap-Changer Transformer

    DEFF Research Database (Denmark)

    Coppo, Massimiliano; Turri, Roberto; Marinelli, Mattia

    2014-01-01

    The paper studies a medium voltage-low voltage transformer with a decoupled on load tap changer capability on each phase. The overall objective is the evaluation of the potential benefits on a low voltage network of such possibility. A realistic Danish low voltage network is used for the analysis....... The load profiles are characterized by using single phase measurement data on voltages, currents and active powers with a 10 minutes resolution. Different scenarios are considered: no tap action, three-phase coordinated tap action, single phase discrete step and single phase continuous tap action...

  18. Binary encoded computer generated holograms for temporal phase shifting.

    Science.gov (United States)

    Amphawan, Angela

    2011-11-07

    The trend towards real-time optical applications predicates the need for real-time interferometry. For real-time interferometric applications, rapid processing of computer generated holograms is crucial as the intractability of rapid phase changes may compromise the input to the system. This paper introduces the design of a set of binary encoded computer generated holograms (CGHs) for real-time five-frame temporal phase shifting interferometry using a binary amplitude spatial light modulator. It is suitable for portable devices with constraints in computational power. The new set of binary encoded CGHs is used for measuring the phase of the generated electric field for a real-time selective launch in multimode fiber. The processing time for the new set of CGHs was reduced by up to 65% relative to the original encoding scheme. The results obtained from the new interferometric technique are in good agreement with the results obtained by phase shifting by means of a piezo-driven flat mirror.

  19. Optical highlighter molecules in neurobiology.

    Science.gov (United States)

    Datta, Sandeep Robert; Patterson, George H

    2012-02-01

    The development of advanced optical methods has played a key role in propelling progress in neurobiology. Genetically-encoded fluorescent molecules found in nature have enabled labeling of individual neurons to study their physiology and anatomy. Here we discuss the recent use of both native and synthetic optical highlighter proteins to address key problems in neurobiology, including questions relevant to synaptic function, neuroanatomy, and the organization of neural circuits. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. The effect of voltage waveform and tube diameter on transporting cold plasma strings through a flexible dielectric tube

    Energy Technology Data Exchange (ETDEWEB)

    Sohbatzadeh, Farshad, E-mail: f.sohbat@umz.ac.ir [Department of Atomic and Molecular Physics, Faculty of Basic Sciences, University of Mazandaran, Babolsar 47416-95447, Mazandaran (Iran, Islamic Republic of); Nano and Biotechnology Research Group, Faculty of Basic Sciences, University of Mazandaran, Babolsar 47416-95447, Mazandaran (Iran, Islamic Republic of); Omran, Azadeh Valinataj [Department of Atomic and Molecular Physics, Faculty of Basic Sciences, University of Mazandaran, Babolsar 47416-95447, Mazandaran (Iran, Islamic Republic of)

    2014-11-15

    In this work, we developed transporting atmospheric pressure cold plasma using single electrode configuration through a sub-millimetre flexible dielectric tube beyond 100 cm. It was shown that the waveform of the applied high voltage is essential for controlling upstream and downstream plasma inside the tube. In this regard, sawtooth waveform enabled the transport of plasma with less applied high voltage compared to sinusoidal and pulsed form voltages. A cold plasma string as long as 130 cm was obtained by only 4 kV peak-to-peak sawtooth high voltage waveform. Optical emission spectroscopy revealed that reactive chemical species, such as atomic oxygen and hydroxyl, are generated at the tube exit. The effect of tube diameter on the transported plasma was also examined: the smaller the diameter, the higher the applied voltage. The device is likely to be used for sterilization, decontamination, and therapeutic endoscopy as already suggested by other groups in recent past years.

  1. 47 CFR 11.32 - EAS Encoder.

    Science.gov (United States)

    2010-10-01

    ... must additionally provide the following minimum specifications: (1) Encoder programming. Access to encoder programming shall be protected by a lock or other security measures and be configured so that... fundamental frequencies of 853 and 960 Hz and not vary over ±0.5 Hz. (ii) Harmonic Distortion. The total...

  2. Effects of diazepam on encoding processes

    NARCIS (Netherlands)

    Gorissen, M.; Eling, P.; Luijtelaar, G. van; Coenen, A.

    1995-01-01

    Benzodiazepines are known to induce amnesic effects. To specify these effects more precisely, 40 healthy volunteers were given 15 mg diazepam or placebo. Effects on a chain of encoding operations were investigated: activation of memory representations, spreading of activation, semantic encoding and

  3. Regularity-Preserving but not Reflecting Encodings

    NARCIS (Netherlands)

    Endrullis, J.; Grabmayer, C.A.; Hendriks, R.D.A.; Palamidessi, C.

    2015-01-01

    Encodings, that is, injective functions from words to words, have been studied extensively in several settings. In computability theory the notion of encoding is crucial for defining computability on arbitrary domains, as well as for comparing the power of models of computation. In language theory

  4. Cellular encoding for interactive evolutionary robotics

    NARCIS (Netherlands)

    F.C. Gruau; K. Quatramaran

    1996-01-01

    textabstractThis work reports experiments in interactive evolutionary robotics. The goal is to evolve an Artificial Neural Network (ANN) to control the locomotion of an 8-legged robot. The ANNs are encoded using a cellular developmental process called cellular encoding. In a previous work similar

  5. Encoding information using Laguerre Gaussian modes

    Science.gov (United States)

    Trichili, Abderrahmen; Dudley, Angela; Ben Salem, Amine; Ndagano, Bienvenu; Zghal, Mourad; Forbes, Andrew

    2015-08-01

    We experimentally demonstrate an information encoding protocol using the two degrees of freedom of Laguerre Gaussian modes having different radial and azimuthal components. A novel method, based on digital holography, for information encoding and decoding using different data transmission scenarios is presented. The effects of the atmospheric turbulence introduced in free space communication is discussed as well.

  6. Self-perpetuating development of encoding biases.

    Science.gov (United States)

    Lewicki, P; Hill, T; Sasaki, I

    1989-12-01

    The process of encoding new information involves the imposition of preexisting interpretive categories on newly encountered stimuli, even if the categories do not match perfectly those stimuli. We hypothesized that such encoding of stimuli as supportive of preexisting encoding dispositions may become a source of a perceiver's subjective experiences that support these dispositions. Through this nonconsciously operating mechanism, encoding rules may gradually develop in a self-perpetuating manner, even in the absence of any objectively supportive evidence. Results demonstrated this self-perpetuating process in three studies involving different stimulus materials and experimental tasks (matrix-scanning paradigm and two "intuitive judgment" tasks). The self-perpetuating development of encoding biases is discussed as one of the elementary mechanisms involved in the development of interpretive categories and other individually differentiated cognitive dispositions.

  7. The Arabic Diatessaron Project: Digitalizing, Encoding, Lemmatization

    Directory of Open Access Journals (Sweden)

    Giuliano Lancioni

    2016-04-01

    Full Text Available The Arabic Diatessaron Project (henceforth ADP is an international research project in Digital Humanities that aims to collect, digitalise and encode all known manuscripts of the Arabic Diatessaron (henceforth AD, a text that has been relatively neglected in scholarly research. ADP’s final goal is to provide a number of tools that can enable scholars to effectively query, compare and investigate all known variants of the text that will be encoded as far as possible in compliance with the Text Encoding Initiative (TEI guidelines. The paper addresses a number of issues involved in the process of digitalising manuscripts included in the two existing editions (Ciasca 1888 and Marmardji 1935, adding variants in unedited manuscripts, encoding and lemmatising the text. Issues involved in the design of the ADP include presentation of variants, choice of the standard text, applicability of TEI guidelines, automatic translation between different encodings, cross-edition concordances and principles of lemmatisation.

  8. A model for visual memory encoding.

    Directory of Open Access Journals (Sweden)

    Rodolphe Nenert

    Full Text Available Memory encoding engages multiple concurrent and sequential processes. While the individual processes involved in successful encoding have been examined in many studies, a sequence of events and the importance of modules associated with memory encoding has not been established. For this reason, we sought to perform a comprehensive examination of the network for memory encoding using data driven methods and to determine the directionality of the information flow in order to build a viable model of visual memory encoding. Forty healthy controls ages 19-59 performed a visual scene encoding task. FMRI data were preprocessed using SPM8 and then processed using independent component analysis (ICA with the reliability of the identified components confirmed using ICASSO as implemented in GIFT. The directionality of the information flow was examined using Granger causality analyses (GCA. All participants performed the fMRI task well above the chance level (>90% correct on both active and control conditions and the post-fMRI testing recall revealed correct memory encoding at 86.33 ± 5.83%. ICA identified involvement of components of five different networks in the process of memory encoding, and the GCA allowed for the directionality of the information flow to be assessed, from visual cortex via ventral stream to the attention network and then to the default mode network (DMN. Two additional networks involved in this process were the cerebellar and the auditory-insular network. This study provides evidence that successful visual memory encoding is dependent on multiple modules that are part of other networks that are only indirectly related to the main process. This model may help to identify the node(s of the network that are affected by a specific disease processes and explain the presence of memory encoding difficulties in patients in whom focal or global network dysfunction exists.

  9. A model for visual memory encoding.

    Science.gov (United States)

    Nenert, Rodolphe; Allendorfer, Jane B; Szaflarski, Jerzy P

    2014-01-01

    Memory encoding engages multiple concurrent and sequential processes. While the individual processes involved in successful encoding have been examined in many studies, a sequence of events and the importance of modules associated with memory encoding has not been established. For this reason, we sought to perform a comprehensive examination of the network for memory encoding using data driven methods and to determine the directionality of the information flow in order to build a viable model of visual memory encoding. Forty healthy controls ages 19-59 performed a visual scene encoding task. FMRI data were preprocessed using SPM8 and then processed using independent component analysis (ICA) with the reliability of the identified components confirmed using ICASSO as implemented in GIFT. The directionality of the information flow was examined using Granger causality analyses (GCA). All participants performed the fMRI task well above the chance level (>90% correct on both active and control conditions) and the post-fMRI testing recall revealed correct memory encoding at 86.33 ± 5.83%. ICA identified involvement of components of five different networks in the process of memory encoding, and the GCA allowed for the directionality of the information flow to be assessed, from visual cortex via ventral stream to the attention network and then to the default mode network (DMN). Two additional networks involved in this process were the cerebellar and the auditory-insular network. This study provides evidence that successful visual memory encoding is dependent on multiple modules that are part of other networks that are only indirectly related to the main process. This model may help to identify the node(s) of the network that are affected by a specific disease processes and explain the presence of memory encoding difficulties in patients in whom focal or global network dysfunction exists.

  10. Power inverter with optical isolation

    Science.gov (United States)

    Duncan, Paul G.; Schroeder, John Alan

    2005-12-06

    An optically isolated power electronic power conversion circuit that includes an input electrical power source, a heat pipe, a power electronic switch or plurality of interconnected power electronic switches, a mechanism for connecting the switch to the input power source, a mechanism for connecting comprising an interconnecting cable and/or bus bar or plurality of interconnecting cables and/or input bus bars, an optically isolated drive circuit connected to the switch, a heat sink assembly upon which the power electronic switch or switches is mounted, an output load, a mechanism for connecting the switch to the output load, the mechanism for connecting including an interconnecting cable and/or bus bar or plurality of interconnecting cables and/or output bus bars, at least one a fiber optic temperature sensor mounted on the heat sink assembly, at least one fiber optic current sensor mounted on the load interconnection cable and/or output bus bar, at least one fiber optic voltage sensor mounted on the load interconnection cable and/or output bus bar, at least one fiber optic current sensor mounted on the input power interconnection cable and/or input bus bar, and at least one fiber optic voltage sensor mounted on the input power interconnection cable and/or input bus bar.

  11. Phylogeny unites animal sodium leak channels with fungal calcium channels in an ancient, voltage-insensitive clade.

    Science.gov (United States)

    Liebeskind, Benjamin J; Hillis, David M; Zakon, Harold H

    2012-12-01

    Proteins in the superfamily of voltage-gated ion channels mediate behavior across the tree of life. These proteins regulate the movement of ions across cell membranes by opening and closing a central pore that controls ion flow. The best-known members of this superfamily are the voltage-gated potassium, calcium (Ca(v)), and sodium (Na(v)) channels, which underlie impulse conduction in nerve and muscle. Not all members of this family are opened by changes in voltage, however. NALCN (NA(+) leak channel nonselective) channels, which encode a voltage-insensitive "sodium leak" channel, have garnered a growing interest. This study examines the phylogenetic relationship among Na(v)/Ca(v) voltage-gated and voltage-insensitive channels in the eukaryotic group Opisthokonta, which includes animals, fungi, and their unicellular relatives. We show that NALCN channels diverged from voltage-gated channels before the divergence of fungi and animals and that the closest relatives of NALCN channels are fungal calcium channels, which they functionally resemble.

  12. High voltage electricity installations a planning perspective

    CERN Document Server

    Jay, Stephen Andrew

    2006-01-01

    The presence of high voltage power lines has provoked widespread concern for many years. High Voltage Electricity Installations presents an in-depth study of policy surrounding the planning of high voltage installations, discussing the manner in which they are percieved by the public, and the associated environmental issues. An analysis of these concerns, along with the geographical, environmental and political influences that shape their expression, is presented. Investigates local planning policy in an area of the energy sector that is of highly topical environmental and public concern Cover

  13. Monte Carlo simulations of microchannel plate detectors. II. Pulsed voltage results.

    Science.gov (United States)

    Kruschwitz, Craig A; Wu, Ming; Rochau, Greg A

    2011-02-01

    This paper is the second part of a continuing study of straight-channel microchannel plate (MCP)-based x-ray detectors. Such detectors are a useful diagnostic tool for two-dimensional, time-resolved imaging and time-resolved x-ray spectroscopy. To interpret the data from such detectors, it is critical to develop a better understanding of the behavior of MCPs biased with subnanosecond voltage pulses. The subject of this paper is a Monte Carlo computer code that simulates the electron cascade in a MCP channel under an arbitrary pulsed voltage, particularly those pulses with widths comparable to the transit time of the electron cascade in the MCP under DC voltage bias. We use this code to study the gain as a function of time (also called the gate profile or optical gate) for various voltage pulse shapes, including pulses measured along the MCP. In addition, experimental data of MCP behavior in pulsed mode are obtained with a short-pulse UV laser. Comparisons between the simulations and experimental data show excellent agreement for both the gate profile and the peak relative sensitivity along the MCP strips. We report that the dependence of relative gain on peak voltage is larger in pulsed mode when the width of the high-voltage waveform is smaller than the transit time of cascading electrons in the MCP.

  14. Direct observation of voltage barriers in ZnO varistors

    Science.gov (United States)

    Krivanek, O. L.; Williams, P.; Lin, Y.-C.

    1979-01-01

    Voltage barriers in a ZnO varistor have been imaged by voltage-contrast scanning electron microscopy. They are due to grain boundaries and are capable of supporting voltage differences of up to about 4 V.

  15. Encoding of coordination complexes with XML.

    Science.gov (United States)

    Vinoth, P; Sankar, P

    2017-09-01

    An in-silico system to encode structure, bonding and properties of coordination complexes is developed. The encoding is achieved through a semantic XML markup frame. Composition of the coordination complexes is captured in terms of central atom and ligands. Structural information of central atom is detailed in terms of electron status of valence electron orbitals. The ligands are encoded with specific reference to the electron environment of ligand centre atoms. Behaviour of ligands to form low or high spin complexes is accomplished by assigning a Ligand Centre Value to every ligand based on the electronic environment of ligand centre atom. Chemical ontologies are used for categorization purpose and to control different hybridization schemes. Complexes formed by the central atoms of transition metal, non-transition elements belonging to s-block, p-block and f-block are encoded with a generic encoding platform. Complexes of homoleptic, heteroleptic and bridged types are also covered by this encoding system. Utility of the encoded system to predict redox electron transfer reaction in the coordination complexes is demonstrated with a simple application. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. High voltage and electrical insulation engineering

    CERN Document Server

    Arora, Ravindra

    2011-01-01

    "The book is written for students as well as for teachers and researchers in the field of High Voltage and Insulation Engineering. It is based on the advance level courses conducted at TU Dresden, Germany and Indian Institute of Technology Kanpur, India. The book has a novel approach describing the fundamental concept of field dependent behavior of dielectrics subjected to high voltage. There is no other book in the field of high voltage engineering following this new approach in describing the behavior of dielectrics. The contents begin with the description of fundamental terminology in the subject of high voltage engineering. It is followed by the classification of electric fields and the techniques of field estimation. Performance of gaseous, liquid and solid dielectrics under different field conditions is described in the subsequent chapters. Separate chapters on vacuum as insulation and the lightning phenomenon are included"--

  17. Pyrotechnic Simulator/Stray-Voltage Detector

    Science.gov (United States)

    Greenfield, Terry

    2009-01-01

    The concept for a dual test item has been developed for use in simulating live initiators/detonators during ground testing to verify the proper operation of the safing and firing circuitry for ground and flight systems ordnance as well as continuous monitoring for any stray voltages. Previous ordnance simulators have consisted of fuses, flash bulbs, inert devices with bridge wires, and actual live ordnance items mounted in test chambers. Stray voltage detectors have included devices connected to the firing circuits for continuous monitoring and a final no-voltage test just prior to ordnance connection. The purpose of this combined ordnance simulation and stray-voltage detection is to provide an improved and comprehensive method to ensure the ordnance circuitry is verified safe and operational.

  18. Compact, Lightweight, High Voltage Propellant Isolators Project

    Data.gov (United States)

    National Aeronautics and Space Administration — TA&T, Inc. proposes an enabling fabrication process for high voltage isolators required in high power solar electric and nuclear electric propulsion (SEP and...

  19. Cascode-based voltage-amplifier stage

    Directory of Open Access Journals (Sweden)

    Pospisilik Martin

    2017-01-01

    Full Text Available Voltage-amplifier stages are the basic components of commonly used high gain amplifiers the bias and other parameters of whose are set by the external negative feedback. The typical device that uses the voltage-amplifier stage is the operational amplifier. Similar constructions can also be created on the basis of discrete transistors. From the circuit designer’s point of view, the voltage-amplifier stage defines the crucial parameters of the whole unit - the amplification factor, dominant pole of its transfer function and the slew rate. In this paper the proposal on construction of the voltage-amplifier stage based on discrete transistors is described. When connected between the input differential amplifier and the output stage, it allows creating of cheap amplifier for HiFi applications with considerable performance.

  20. Modular high voltage power supply for chemical analysis

    Science.gov (United States)

    Stamps, James F [Livermore, CA; Yee, Daniel D [Dublin, CA

    2008-07-15

    A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

  1. Ultra-low Voltage CMOS Cascode Amplifier

    DEFF Research Database (Denmark)

    Lehmann, Torsten; Cassia, Marco

    2000-01-01

    In this paper, we design a folded cascode operational transconductance amplifier in a standard CMOS process, which has a measured 69 dB DC gain, a 2 MHz bandwidth and compatible input- and output voltage levels at a 1 V power supply. This is done by a novel Current Driven Bulk (CDB) technique......, which reduces the MOST threshold voltage by forcing a constant current though the transistor bulk terminal. We also look at limitations and improvements of this CDB technique....

  2. Voltage, Temperature, Frequency Margin Test Report

    DEFF Research Database (Denmark)

    Denver, Troelz

    1999-01-01

    The purpose of the tests is to establish the camera functionality when it is exposed to an extreme environment for prolonged periods, thus simulating the end of life performance. This environment covers temperature, input clock frequency and supply voltage variation......The purpose of the tests is to establish the camera functionality when it is exposed to an extreme environment for prolonged periods, thus simulating the end of life performance. This environment covers temperature, input clock frequency and supply voltage variation...

  3. RF Voltage Measurements on ICRF Antennas

    Science.gov (United States)

    Bell, G. L.; Goulding, R. H.; Hoffman, D. J.; Wilgen, J. B.; Zhang, H. M.; Ryan, P. M.; Syed, G. M. S.; Kaye, A. S.

    1996-11-01

    Particle and heat flux on the plasma facing surfaces of high-power RF antennas used in fusion devices can result in damage to the antenna structures. High impedance capacitive probe measurements of the RF voltages on Faraday shields of several loop antennas indicate that voltages as high as 30% of the drive voltage can exist for 0/0 phasing (D.J. Hoffman, et al., AIP Conf. Proc. 355), 368 (Palm Spgs., CA, 1995).. These voltages can contribute to increased energy deposition on the antenna owing to increased RF sheath voltages. We report on continued efforts to understand the source and to control these RF voltages. E and B field distributions have been measured on the mock-up of the JET A2 antenna using standard B-dot probes and novel E-field probes positioned with a new automated scanning system. These data are compared with calculated fields from 3-D antenna models. The measurements demonstrate the dependency of the surface E-fields on the phasing of the strap currents and show the charge accumulation at the antenna top and bottom predicted by the models.

  4. VKCDB: Voltage-gated potassium channel database

    Directory of Open Access Journals (Sweden)

    Gallin Warren J

    2004-01-01

    Full Text Available Abstract Background The family of voltage-gated potassium channels comprises a functionally diverse group of membrane proteins. They help maintain and regulate the potassium ion-based component of the membrane potential and are thus central to many critical physiological processes. VKCDB (Voltage-gated potassium [K] Channel DataBase is a database of structural and functional data on these channels. It is designed as a resource for research on the molecular basis of voltage-gated potassium channel function. Description Voltage-gated potassium channel sequences were identified by using BLASTP to search GENBANK and SWISSPROT. Annotations for all voltage-gated potassium channels were selectively parsed and integrated into VKCDB. Electrophysiological and pharmacological data for the channels were collected from published journal articles. Transmembrane domain predictions by TMHMM and PHD are included for each VKCDB entry. Multiple sequence alignments of conserved domains of channels of the four Kv families and the KCNQ family are also included. Currently VKCDB contains 346 channel entries. It can be browsed and searched using a set of functionally relevant categories. Protein sequences can also be searched using a local BLAST engine. Conclusions VKCDB is a resource for comparative studies of voltage-gated potassium channels. The methods used to construct VKCDB are general; they can be used to create specialized databases for other protein families. VKCDB is accessible at http://vkcdb.biology.ualberta.ca.

  5. Prediction of breakdown voltages in novel gases for high voltage insulation

    Energy Technology Data Exchange (ETDEWEB)

    Koch, M.

    2015-07-01

    This thesis submitted to the Swiss Federal Institute of Technology ETH in Zurich examines the use of sulphur hexafluoride (SF{sub 6}) and similar gases as important insulation media for high voltage equipment. Due to its superior insulation properties, SF{sub 6} is widely used in gas-insulated switchgear. However, the gas also has a very high global warming potential and the content of SF{sub 6} in the atmosphere is constantly increasing. The search for new insulation gases using classical breakdown experiments is discussed. A model for SF{sub 6} based on the stepped leader model is described. This calculates the breakdown voltages in arbitrary electrode configurations and under standard voltage waveforms. Thus, the thesis provides a method for the prediction of breakdown voltages of arbitrary field configurations under standard voltage waveforms for gases with electron-attaching properties. With this, further gases can be characterized for usage as high voltage insulation media.

  6. Design of dual-core optical fibers with NEMS functionality.

    Science.gov (United States)

    Podoliak, Nina; Lian, Zhenggang; Loh, Wei H; Horak, Peter

    2014-01-13

    An optical fiber with nano-electromechanical functionality is presented. The fiber exhibits a suspended dual-core structure that allows for control of the optical properties via nanometer-range mechanical movements. We investigate electrostatic actuation achieved by applying a voltage to specially designed electrodes integrated in the cladding. Numerical and analytical calculations are preformed to optimize the fiber and electrode design. Based on this geometry an all-fiber optical switch is investigated; we find that optical switching of light between the two cores can be achieved in a 10 cm fiber with an operating voltage of 35 V.

  7. Multiplex immunoassay for persistent organic pollutants in tilapia: Comparison of imaging- and flow cytometry-based platforms using spectrally encoded paramagnetic microspheres

    Science.gov (United States)

    Recent developments in spectrally encoded microspheres (SEMs)-based technologies provide high multiplexing possibilities. Most SEMs-based assays required a flow cytometer with sophisticated fluidics and optics. The new imaging superparamagnetic SEMs-based platform transports SEMs with considerably ...

  8. Experimental generation of optical coherence lattices

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yahong; Cai, Yangjian, E-mail: serpo@dal.ca, E-mail: yangjiancai@suda.edu.cn [College of Physics, Optoelectronics and Energy and Collaborative Innovation Center of Suzhou Nano Science and Technology, Soochow University, Suzhou 215006 (China); Key Lab of Advanced Optical Manufacturing Technologies of Jiangsu Province and Key Lab of Modern Optical Technologies of Education Ministry of China, Soochow University, Suzhou 215006 (China); Ponomarenko, Sergey A., E-mail: serpo@dal.ca, E-mail: yangjiancai@suda.edu.cn [Department of Electrical and Computer Engineering, Dalhousie University, Halifax, Nova Scotia B3J 2X4 (Canada)

    2016-08-08

    We report experimental generation and measurement of recently introduced optical coherence lattices. The presented optical coherence lattice realization technique hinges on a superposition of mutually uncorrelated partially coherent Schell-model beams with tailored coherence properties. We show theoretically that information can be encoded into and, in principle, recovered from the lattice degree of coherence. Our results can find applications to image transmission and optical encryption.

  9. All-optical processing with molecular switches

    OpenAIRE

    Raymo, Françisco M.; Giordani, Silvia

    2002-01-01

    A gradual transition from electrical to optical networks is accompanying the rapid progress of telecommunication technology. The urge for enhanced transmission capacity and speed is dictating this trend. In fact, large volumes of data encoded on optical signals can be transported rapidly over long distances. Their propagation along specific routes across a communication network is ensured by a combination of optical fibers and optoelectronic switches. It is becoming appar...

  10. Electrifying photonic metamaterials for tunable nonlinear optics.

    Science.gov (United States)

    Kang, Lei; Cui, Yonghao; Lan, Shoufeng; Rodrigues, Sean P; Brongersma, Mark L; Cai, Wenshan

    2014-08-11

    Metamaterials have not only enabled unprecedented flexibility in producing unconventional optical properties that are not found in nature, they have also provided exciting potential to create customized nonlinear media with high-order properties correlated to linear behaviour. Two particularly compelling directions are active metamaterials, whose optical properties can be purposely tailored by external stimuli in a reversible manner, and nonlinear metamaterials, which enable intensity-dependent frequency conversion of light waves. Here, by exploring the interaction of these two directions, we leverage the electrical and optical functions simultaneously supported in nanostructured metals and demonstrate electrically controlled nonlinear optical processes from a metamaterial. Both second harmonic generation and optical rectification, enhanced by the resonance behaviour in the metamaterial absorber, are modulated externally with applied voltage signals. Our results reveal an opportunity to exploit optical metamaterials as self-contained, dynamic electro-optic systems with intrinsically embedded electrical functions and optical nonlinearities.

  11. Mitigation of Voltage Dip and Voltage Flickering by Multilevel D-STATCOM

    Directory of Open Access Journals (Sweden)

    M. S. Ballal

    2012-01-01

    Full Text Available The basic power quality problems in the distribution network are voltage sag (dip, voltage flickering, and the service interruptions. STATCOM is a Flexible AC Transmission Systems (FACTS technology device which can independently control the flow of reactive power. This paper presents the simulation and analysis of a STATCOM for voltage dip and voltage flickering mitigation. Simulations are carried out in MATLAB/Simulink to validate the performance of the STATCOM. A comparison between the six-pulse inverter and the five-level diode-clamped inverter is carried out for the performance of 66/11 KV distribution system.

  12. Control and Testing of a Dynamic Voltage Restorer (DVR) at Medium Voltage Level

    DEFF Research Database (Denmark)

    Nielsen, John Godsk; Newman, Michael; Nielsen, Hans Ove

    2004-01-01

    The dynamic voltage restorer (DVR) has become popular as a cost effective solution for the protection of sensitive loads from voltage sags. Implementations of the DVR have been proposed at both a low voltage (LV) level, as well as a medium voltage (MV) level; and give an opportunity to protect high...... power sensitive loads from voltage sags. This paper reports practical test results obtained on a medium voltage (10 kV) level using a DVR at a Distribution test facility in Kyndby, Denmark. The DVR was designed to protect a 400-kVA load from a 0.5-p.u. maximum voltage sag. The reported DVR verifies...... duration voltage sags were created using a controllable LV breaker fed by a 630 kVA Distribution transformer placed upstream of the sensitive load. The fault currents in excess of 12 kA were designed and created to obtain the required voltage sags. It is concluded the DVR works well in all operating...

  13. Encoding information using laguerre gaussian modes

    CSIR Research Space (South Africa)

    Trichili, A

    2015-08-01

    Full Text Available The authors experimentally demonstrate an information encoding protocol using the two degrees of freedom of Laguerre Gaussian modes having different radial and azimuthal components. A novel method, based on digital holography, for information...

  14. Using XML to encode TMA DES metadata

    Directory of Open Access Journals (Sweden)

    Oliver Lyttleton

    2011-01-01

    Full Text Available Background: The Tissue Microarray Data Exchange Specification (TMA DES is an XML specification for encoding TMA experiment data. While TMA DES data is encoded in XML, the files that describe its syntax, structure, and semantics are not. The DTD format is used to describe the syntax and structure of TMA DES, and the ISO 11179 format is used to define the semantics of TMA DES. However, XML Schema can be used in place of DTDs, and another XML encoded format, RDF, can be used in place of ISO 11179. Encoding all TMA DES data and metadata in XML would simplify the development and usage of programs which validate and parse TMA DES data. XML Schema has advantages over DTDs such as support for data types, and a more powerful means of specifying constraints on data values. An advantage of RDF encoded in XML over ISO 11179 is that XML defines rules for encoding data, whereas ISO 11179 does not. Materials and Methods: We created an XML Schema version of the TMA DES DTD. We wrote a program that converted ISO 11179 definitions to RDF encoded in XML, and used it to convert the TMA DES ISO 11179 definitions to RDF. Results: We validated a sample TMA DES XML file that was supplied with the publication that originally specified TMA DES using our XML Schema. We successfully validated the RDF produced by our ISO 11179 converter with the W3C RDF validation service. Conclusions: All TMA DES data could be encoded using XML, which simplifies its processing. XML Schema allows datatypes and valid value ranges to be specified for CDEs, which enables a wider range of error checking to be performed using XML Schemas than could be performed using DTDs.

  15. Using XML to encode TMA DES metadata.

    Science.gov (United States)

    Lyttleton, Oliver; Wright, Alexander; Treanor, Darren; Lewis, Paul

    2011-01-01

    The Tissue Microarray Data Exchange Specification (TMA DES) is an XML specification for encoding TMA experiment data. While TMA DES data is encoded in XML, the files that describe its syntax, structure, and semantics are not. The DTD format is used to describe the syntax and structure of TMA DES, and the ISO 11179 format is used to define the semantics of TMA DES. However, XML Schema can be used in place of DTDs, and another XML encoded format, RDF, can be used in place of ISO 11179. Encoding all TMA DES data and metadata in XML would simplify the development and usage of programs which validate and parse TMA DES data. XML Schema has advantages over DTDs such as support for data types, and a more powerful means of specifying constraints on data values. An advantage of RDF encoded in XML over ISO 11179 is that XML defines rules for encoding data, whereas ISO 11179 does not. We created an XML Schema version of the TMA DES DTD. We wrote a program that converted ISO 11179 definitions to RDF encoded in XML, and used it to convert the TMA DES ISO 11179 definitions to RDF. We validated a sample TMA DES XML file that was supplied with the publication that originally specified TMA DES using our XML Schema. We successfully validated the RDF produced by our ISO 11179 converter with the W3C RDF validation service. All TMA DES data could be encoded using XML, which simplifies its processing. XML Schema allows datatypes and valid value ranges to be specified for CDEs, which enables a wider range of error checking to be performed using XML Schemas than could be performed using DTDs.

  16. Reading Neural Encodings using Phase Space Methods

    OpenAIRE

    Abarbanel, Henry D. I.; Tumer, Evren C.

    2003-01-01

    Environmental signals sensed by nervous systems are often represented in spike trains carried from sensory neurons to higher neural functions where decisions and functional actions occur. Information about the environmental stimulus is contained (encoded) in the train of spikes. We show how to "read" the encoding using state space methods of nonlinear dynamics. We create a mapping from spike signals which are output from the neural processing system back to an estimate of the analog input sig...

  17. Artificial neural networks using complex numbers and phase encoded weights.

    Science.gov (United States)

    Michel, Howard E; Awwal, Abdul Ahad S

    2010-04-01

    The model of a simple perceptron using phase-encoded inputs and complex-valued weights is proposed. The aggregation function, activation function, and learning rule for the proposed neuron are derived and applied to Boolean logic functions and simple computer vision tasks. The complex-valued neuron (CVN) is shown to be superior to traditional perceptrons. An improvement of 135% over the theoretical maximum of 104 linearly separable problems (of three variables) solvable by conventional perceptrons is achieved without additional logic, neuron stages, or higher order terms such as those required in polynomial logic gates. The application of CVN in distortion invariant character recognition and image segmentation is demonstrated. Implementation details are discussed, and the CVN is shown to be very attractive for optical implementation since optical computations are naturally complex. The cost of the CVN is less in all cases than the traditional neuron when implemented optically. Therefore, all the benefits of the CVN can be obtained without additional cost. However, on those implementations dependent on standard serial computers, CVN will be more cost effective only in those applications where its increased power can offset the requirement for additional neurons.

  18. Remotely operated compact underwater temporally encoded imager: CUTEI

    Science.gov (United States)

    Alley, Derek; Cochenour, Brandon; Mullen, Linda

    2016-05-01

    Remotely operated vehicles (ROVs) typically use traditional optical imaging systems, such as cameras, for high resolution imaging. Cameras are effective in clear water, but have extremely poor performance in degraded visual environments (DVEs) such as turbid coastal waters and harbors. This is due to the multiple scattering of the light from the particulates and organic matter in the water. Laser-based sensors have been developed to enhance optical imaging in DVEs1,3,4,5,6. However, since conventional approaches require that the illuminator and receiver be located on the same platform, the size, weight, and power (SWaP) requirements are incompatible with small ROVs. Researchers at NAVAIR have developed a low cost optical imager utilizing a bistatic geometry where the illuminator and receiver are mounted on separate, smaller platforms. The illuminator steers a modulated laser beam with a microelectromechanical system (MEMS) scanner to sequentially illuminate an underwater object. A distant receiver collects the object reflected laser light and reconstructs the imagery. Communications information, including a synchronization sequence, is encoded onto the modulation which is used by the receiver to build the image. The SWaP of the illuminator's components have been optimized and integrated into a modified version of the OpenROV, a miniature, commercial off-the-shelf ROV. This paper reports on the efforts to reduce the SWaP of the modulated illuminator and the results of testing this system in a laboratory water tank environment.

  19. Very low power, high voltage base for a Photo Multiplier Tube for the KM3NeT deep sea neutrino telescope

    CERN Document Server

    Timmer, P; Peek, H

    2010-01-01

    The described system is developed in the framework of a deep-sea submerged Very Large Volume neutrino Telescope where photons are detected by a large number of Photo Multiplier Tubes. These PMTs are placed in optical modules (OM). A basic Cockcroft-Walton (CW) voltage multiplier circuit design is used to generate multiple voltages to drive the dynodes of the photomultiplier tube. To achieve a long lifetime and a high reliability the dissipation in the OM must be kept to the minimum. The design is also constrained by size restrictions, load current, voltage range, and the maximum allowable ripple in the output voltage. A surface mount PMT-base PCB prototype is designed and successfully tested. The system draws less than 1.5 mA of supply current at a voltage of 3.3 V with outputs up to -1400 Vdc cathode voltage, a factor 10 less than the commercially available state of the art

  20. Voltage Unbalance Compensation with Smart Three-phase Loads

    DEFF Research Database (Denmark)

    Douglass, Philip; Trintis, Ionut; Munk-Nielsen, Stig

    2016-01-01

    This paper describes the design, proof-of-concept simulations and laboratory test of an algorithm for controlling active front-end rectifiers to reduce voltage unbalance. Using inputs of RMS voltage, the rectifier controller allocates load unevenly on its 3 phases to compensate for voltage...... unbalance originating in the power supply network. Two variants of the algorithm are tested: first, using phase-neutral voltage as input, second, using phase-phase voltage. The control algorithm is described, and evaluated in simulations and laboratory tests. Two metrics for quantifying voltage unbalance...... are evaluated: one metric based on the maximum deviation of RMS phaseneutral voltage from the average voltage and one metric based on negative sequence voltage. The tests show that controller that uses phase-neutral voltage as input can in most cases eliminate the deviations of phase voltage from the average...

  1. An accurate continuous calibration system for high voltage current transformer.

    Science.gov (United States)

    Tong, Yue; Li, Bin Hong

    2011-02-01

    A continuous calibration system for high voltage current transformers is presented in this paper. The sensor of this system is based on a kind of electronic instrument current transformer, which is a clamp-shape air core coil. This system uses an optical fiber transmission system for its signal transmission and power supply. Finally the digital integrator and fourth-order convolution window algorithm as error calculation methods are realized by the virtual instrument with a personal computer. It is found that this system can calibrate a high voltage current transformer while energized, which means avoiding a long calibrating period in the power system and the loss of power metering expense. At the same time, it has a wide dynamic range and frequency band, and it can achieve a high accuracy measurement in a complex electromagnetic field environment. The experimental results and the on-site operation results presented in the last part of the paper, prove that it can reach the 0.05 accuracy class and is easy to operate on site.

  2. Temperature independent low voltage polymer stabilized blue phase liquid crystals

    Science.gov (United States)

    Kemiklioglu, E.; Hwang, J. Y.; Chien, L.-C.

    2012-03-01

    Blue phases are types of liquid crystal phase which can appear in a narrow temperature range between a chiral nematic phase and isotropic liquid phase. Blue Phase (BP) liquid crystals have been known to exist in a small temperature range. Recently, broadening the temperature range of a BP liquid crystal has occurred by using a mixture of nematic bimesogenic liquid crystals or by polymerizing a small amount of monomer in a BP to stabilize the cubic lattice against temperature variation. In this study, we report a low switching voltage polymer stabilized blue phase (PSBP) liquid crystal device. We showed the stabilization of blue phases over a temperature range of 30.4 °C including room temperature. We observed the temperature independent of Bragg wavelength. Furthermore, the polymer effect on the electo-optic properties of a self assembled nanostructured blue phase liquid crystal composites have been investigated. As well as the ratio between two monomers, the overall monomers concentration is controlled.

  3. Voltage-Sensitive Ion Channels Biophysics of Molecular Excitability

    CERN Document Server

    Leuchtag, H. Richard

    2008-01-01

    Voltage-sensitive ion channels are macromolecules embedded in the membranes of nerve and muscle fibers of animals. Because of their physiological functions, biochemical structures and electrical switching properties, they are at an intersection of biology, chemistry and physics. Despite decades of intensive research under the traditional approach of gated structural pores, the relation between the structure of these molecules and their function remains enigmatic. This book critically examines physically oriented approaches not covered in other ion-channel books. It looks at optical and thermal as well as electrical data, and at studies in the frequency domain as well as in the time domain. Rather than presenting the reader with only an option of mechanistic models at an inappropriate pseudo-macroscopic scale, it emphasizes concepts established in organic chemistry and condensed state physics. The book’s approach to the understanding of these unique structures breaks with the unproven view of ion channels as...

  4. Optical Computing

    Indian Academy of Sciences (India)

    tal computers are still some years away, however a number of devices that can ultimately lead to real optical computers have already been manufactured, including optical logic gates, optical switches, optical interconnections, and opti- cal memory. The most likely near-term optical computer will really be a hybrid composed ...

  5. Investigation of phase-wise voltage regulator control logics for compensating voltage deviations in an experimental low voltage network

    DEFF Research Database (Denmark)

    Hu, Junjie; Zecchino, Antonio; Marinelli, Mattia

    2016-01-01

    This paper investigates the control logics of an on-load tap-changer (OLTC) transformer by means of an experimental system validation. The experimental low-voltage unbalanced system consists of a decoupled single-phase OLTC transformer, a 75-metre 16 mm2 cable, a controllable single-phase resistive...... load and an electric vehicle, which has the vehicle-to-grid function. Three control logics of the OLTC transformer are described in the study. The three control logics are classified based on their control objectives and control inputs, which include network currents and voltages, and can be measured...... either locally or remotely. To evaluate and compare the control performances of the three control logics, all the tests use the same loading profiles. The experimental results indicate that the modified line compensation control can regulate voltage in a safe band in the case of various load...

  6. Encoder: a connectionist model of how learning to visually encode fixated text images improves reading fluency.

    Science.gov (United States)

    Martin, Gale L

    2004-07-01

    This article proposes that visual encoding learning improves reading fluency by widening the span over which letters are recognized from a fixated text image so that fewer fixations are needed to cover a text line. Encoder is a connectionist model that learns to convert images like the fixated text images human readers encode into the corresponding letter sequences. The computational theory of classification learning predicts that fixated text-image size makes this learning difficult but that reducing image variability and biasing learning should help. Encoder confirms these predictions. It fails to learn as image size increases but achieves humanlike visual encoding accuracy when image variability is reduced by regularities in fixation positions and letter sequences and when learning is biased to discover mapping functions based on the sequential, componential structure of text. After training, Encoder exhibits many humanlike text familiarity effects. ((c) 2004 APA, all rights reserved)

  7. Voltage-gated sodium channels: therapeutic targets for pain.

    Science.gov (United States)

    Dib-Hajj, Sulayman D; Black, Joel A; Waxman, Stephen G

    2009-10-01

    To provide an overview of the role of voltage-gated sodium channels in pathophysiology of acquired and inherited pain states, and of recent developments that validate these channels as therapeutic targets for treating chronic pain. Neuropathic and inflammatory pain conditions are major medical needs worldwide with only partial or low efficacy treatment options currently available. An important role of voltage-gated sodium channels in many different pain states has been established in animal models and, empirically, in humans, where sodium channel blockers partially ameliorate pain. Animal studies have causally linked changes in sodium channel expression and modulation that alter channel gating properties or current density in nociceptor neurons to different pain states. Biophysical and pharmacological studies have identified the sodium channel isoforms Na(v)1.3, Na(v)1.7, Na(v)1.8, and Na(v)1.9 as particularly important in the pathophysiology of different pain syndromes. Recently, gain-of-function mutations in SCN9A, the gene which encodes Na(v)1.7, have been linked to two human-inherited pain syndromes, inherited erythromelalgia and paroxysmal extreme pain disorder, while loss-of-function mutations in SCN9A have been linked to complete insensitivity to pain. Studies on firing properties of sensory neurons of dorsal root ganglia demonstrate that the effects of gain-of-function mutations in Na(v)1.7 on the excitability of these neurons depend on the presence of Na(v)1.8, which suggests a similar physiological interaction of these two channels in humans carrying the Na(v)1.7 pain mutation. These studies suggest that isoform-specific blockers of these channels or targeting of their modulators may provide novel approaches to treatment of pain.

  8. High voltage testing for the Majorana Demonstrator

    Energy Technology Data Exchange (ETDEWEB)

    Abgrall, N.; Arnquist, Isaac J.; Avignone, F. T.; Barabash, A.; Bertrand, F.; Bradley, A. W.; Brudanin, V.; Busch, Matthew; Buuck, M.; Byram, D.; Caldwell, A. S.; Chan, Yuen-Dat; Christofferson, C. D.; Chu, Pamela M.; Cuesta, C.; Detwiler, Jason A.; Doe, P. J.; Dunagan, C.; Efremenko, Yuri; Ejiri, H.; Elliott, S. R.; Fu, Z.; Galindo-Uribarri, A.; Giovanetti, G. K.; Goett, J.; Green, M. P.; Gruszko, J.; Guinn, I.; Guiseppe, V. E.; Henning, R.; Hoppe, Eric W.; Howard, S.; Howe, M. A.; Jasinski, B. R.; Keeter, K.; Kidd, M. F.; Konovalov, S.; Kouzes, Richard T.; Laferriere, Brian D.; Leon, Jonathan D.; Li, Alexander D.; MacMullin, J.; Martin, R. D.; Massarcyk, R.; Meijer, S. J.; Mertens, S.; Orrell, John L.; O' Shaughnessy, C.; Poon, Alan W.; Radford, D. C.; Rager, J.; Rielage, Keith; Robertson, R. G. H.; Romero Romo, M.; Shanks, B.; Shirchenko, M.; Snyder, N.; Suriano, Anne-Marie E.; Tedeschi, D.; Thompson, Andrew; Ton, K. T.; Trimble, J. E.; Varner, R. L.; Vasilyev, Sergey; Vetter, Kai; Vorren, Kris R.; White, Brandon R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, Chang-Hong; Yumatov, V.

    2016-07-01

    The Majorana Collaboration is constructing theMajorana Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in 76Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of theMajorana Demonstrator. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the Majorana Demonstrator was characterized and the micro-discharge effects during theMajorana Demonstrator commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.

  9. Induced Voltage in an Open Wire

    Science.gov (United States)

    Morawetz, K.; Gilbert, M.; Trupp, A.

    2017-07-01

    A puzzle arising from Faraday's law has been considered and solved concerning the question which voltage will be induced in an open wire with a time-varying homogeneous magnetic field. In contrast to closed wires where the voltage is determined by the time variance of the magnetic field and the enclosed area, in an open wire we have to integrate the electric field along the wire. It is found that the longitudinal electric field with respect to the wave vector contributes with 1/3 and the transverse field with 2/3 to the induced voltage. In order to find the electric fields the sources of the magnetic fields are necessary to know. The representation of a spatially homogeneous and time-varying magnetic field implies unavoidably a certain symmetry point or symmetry line which depend on the geometry of the source. As a consequence the induced voltage of an open wire is found to be the area covered with respect to this symmetry line or point perpendicular to the magnetic field. This in turn allows to find the symmetry points of a magnetic field source by measuring the voltage of an open wire placed with different angles in the magnetic field. We present exactly solvable models of the Maxwell equations for a symmetry point and for a symmetry line, respectively. The results are applicable to open circuit problems like corrosion and for astrophysical applications.

  10. A Bright and Fast Red Fluorescent Protein Voltage Indicator That Reports Neuronal Activity in Organotypic Brain Slices.

    Science.gov (United States)

    Abdelfattah, Ahmed S; Farhi, Samouil L; Zhao, Yongxin; Brinks, Daan; Zou, Peng; Ruangkittisakul, Araya; Platisa, Jelena; Pieribone, Vincent A; Ballanyi, Klaus; Cohen, Adam E; Campbell, Robert E

    2016-02-24

    Optical imaging of voltage indicators based on green fluorescent proteins (FPs) or archaerhodopsin has emerged as a powerful approach for detecting the activity of many individual neurons with high spatial and temporal resolution. Relative to green FP-based voltage indicators, a bright red-shifted FP-based voltage indicator has the intrinsic advantages of lower phototoxicity, lower autofluorescent background, and compatibility with blue-light-excitable channelrhodopsins. Here, we report a bright red fluorescent voltage indicator (fluorescent indicator for voltage imaging red; FlicR1) with properties that are comparable to the best available green indicators. To develop FlicR1, we used directed protein evolution and rational engineering to screen libraries of thousands of variants. FlicR1 faithfully reports single action potentials (∼3% ΔF/F) and tracks electrically driven voltage oscillations at 100 Hz in dissociated Sprague Dawley rat hippocampal neurons in single trial recordings. Furthermore, FlicR1 can be easily imaged with wide-field fluorescence microscopy. We demonstrate that FlicR1 can be used in conjunction with a blue-shifted channelrhodopsin for all-optical electrophysiology, although blue light photoactivation of the FlicR1 chromophore presents a challenge for applications that require spatially overlapping yellow and blue excitation. Copyright © 2016 the authors 0270-6474/16/362459-15$15.00/0.

  11. Resonant optical device with a microheater

    Science.gov (United States)

    Lentine, Anthony L.; DeRose, Christopher

    2017-04-04

    A resonant photonic device is provided. The device comprises an optical waveguiding element, such as an optical resonator, that includes a diode junction region, two signal terminals configured to apply a bias voltage across the junction region, and a heater laterally separated from the optical waveguiding element. A semiconductor electrical barrier element is juxtaposed to the heater. A metallic strip is electrically and thermally connected at one end to a signal terminal of the optical waveguiding element and thermally connected at another end to the barrier element.

  12. Method of implementing frequency-encoded NOT, OR and NOR ...

    Indian Academy of Sciences (India)

    In this context, polarization encoding technique, intensity-based encoding technique, tristate and quaternary logic operation, multivalued logic operations, symbolic substitution techniques etc. may be mentioned. Very recently, frequency encoding/decoding technique has drawn interest from the scientific community.

  13. A monolithic integrated low-voltage deep brain stimulator with wireless power and data transmission

    Science.gov (United States)

    Zhang, Zhang; Ye, Tan; Jianmin, Zeng; Xu, Han; Xin, Cheng; Guangjun, Xie

    2016-09-01

    A monolithic integrated low-voltage deep brain stimulator with wireless power and data transmission is presented. Data and power are transmitted to the stimulator by mutual inductance coupling, while the in-vitro controller encodes the stimulation parameters. The stimulator integrates the digital control module and can generate the bipolar current with equal amplitude in four channels. In order to reduce power consumption, a novel controlled threshold voltage cancellation rectifier is proposed in this paper to provide the supply voltage of the stimulator. The monolithic stimulator was fabricated in a SMIC 0.18 μm 1-poly 6-metal mixed-signal CMOS process, occupying 0.23 mm2, and consumes 180 μW on average. Compared with previously published stimulators, this design has advantages of large stimulated current (0-0.8 mA) with the double low-voltage supply (1.8 and 3.3 V), and high-level integration. Project supported by the National Natural Science Foundation of China (Nos. 61404043, 61401137), the Key Laboratory of Infrared Imaging Materials and Detectors, Shanghai Institute of Technical Physics, Chinese Academy of Sciences (Nos. IIMDKFJJ-13-06, IIMDKFJJ-14-03), and the Fundamental Research Funds for the Central Universities (No. 2015HGZX0026).

  14. Low-Voltage Consumption Coordination for Loss Minimization and Voltage Control

    DEFF Research Database (Denmark)

    Juelsgaard, Morten; Sloth, Christoffer; Wisniewski, Rafal

    2014-01-01

    This work presents a strategy for minimizing active power losses in low-voltage grids, by coordinating the consumption of electric vehicles and power generation from solar panels. We show that minimizing losses, also reduces voltage variations, and illustrate how this may be employed for increasing...

  15. Synchronised Voltage Space Vector Modulation for Three-level Inverters with Common-mode Voltage Elimination

    DEFF Research Database (Denmark)

    Oleschuk, Valentin; Blaabjerg, Frede

    2002-01-01

    A novel method of direct synchronous pulse-width modulation (PWM) is disseminated to three-level voltage source inverters with control algorithms with elimination of the common-mode voltages in three-phase drive systems with PWM. It provides smooth pulses-ratio changing and a quarter-wave symmetry...

  16. Voltage-gated proton (H(v)1) channels, a singular voltage sensing domain.

    Science.gov (United States)

    Castillo, Karen; Pupo, Amaury; Baez-Nieto, David; Contreras, Gustavo F; Morera, Francisco J; Neely, Alan; Latorre, Ramon; Gonzalez, Carlos

    2015-11-14

    The main role of voltage-gated proton channels (Hv1) is to extrude protons from the intracellular milieu when, mediated by different cellular processes, the H(+) concentration increases. Hv1 are exquisitely selective for protons and their structure is homologous to the voltage sensing domain (VSD) of other voltage-gated ion channels like sodium, potassium, and calcium channels. In clear contrast to the classical voltage-dependent channels, Hv1 lacks a pore domain and thus permeation necessarily occurs through the voltage sensing domain. Hv1 channels are activated by depolarizing voltages, and increases in internal proton concentration. It has been proposed that local conformational changes of the transmembrane segment S4, driven by depolarization, trigger the molecular rearrangements that open Hv1. However, it is still unclear how the electromechanical coupling is achieved between the VSD and the potential pore, allowing the proton flux from the intracellular to the extracellular side. Here we provide a revised view of voltage activation in Hv1 channels, offering a comparative scenario with other voltage sensing channels domains. Copyright © 2015 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.

  17. On Secondary Control Approaches for Voltage Regulation in DC Microgrids

    DEFF Research Database (Denmark)

    Peyghami Akhuleh, Saeed; Mokhtari, Hossein; Davari, Pooya

    2017-01-01

    regulation on the load busses within a suitable range. Therefore, in addition to compensate the voltage drop of the primary controller, it is necessary to regulate the voltage of critical loads. In this paper, a new voltage regulation strategy is proposed to regulate the voltage of Micro-Grid (MG...

  18. 30 CFR 75.804 - Underground high-voltage cables.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground high-voltage cables. 75.804 Section... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution § 75.804 Underground high-voltage cables. (a) Underground high-voltage cables used in resistance...

  19. 46 CFR 120.324 - Dual voltage generators.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Dual voltage generators. 120.324 Section 120.324... INSTALLATION Power Sources and Distribution Systems § 120.324 Dual voltage generators. (a) A dual voltage generator installed on a vessel shall be of the grounded type, where: (1) The neutral of a dual voltage...

  20. 30 CFR 77.810 - High-voltage equipment; grounding.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage equipment; grounding. 77.810... COAL MINES Surface High-Voltage Distribution § 77.810 High-voltage equipment; grounding. Frames, supporting structures, and enclosures of stationary, portable, or mobile high-voltage equipment shall be...

  1. 47 CFR 17.54 - Rated lamp voltage.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Rated lamp voltage. 17.54 Section 17.54... voltage. To insure the necessary lumen output by obstruction lights, the rated voltage of incandescent lamps used shall correspond to be within 3 percent higher than the voltage across the lamp socket during...

  2. 46 CFR 129.326 - Dual-voltage generators.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Dual-voltage generators. 129.326 Section 129.326... INSTALLATIONS Power Sources and Distribution Systems § 129.326 Dual-voltage generators. If a dual-voltage generator is installed on an OSV— (a) The neutral of the dual-voltage system must be solidly grounded at the...

  3. A Novel Optical Morse Code-Based Electronic Lock Using the Ambient Light Sensor and Fuzzy Controller

    OpenAIRE

    Chin-Tan Lee; Tung-Chun Shen; Win-Der Lee

    2017-01-01

    In this work, a novel electronic lock that can encode and decode optical signals, modulated using Morse code conventions, was developed to build a smart home security system based on the Internet of Things (IoT). There are five topics of interest in this research: (1) optical Morse code encoder; (2) optical Morse code decoder; (3) ambient light sensor circuit; (4) fuzzy controller; (5) cloud monitoring system. We take advantage of the light-emitting components as the encoder, which are readil...

  4. Active-passive path-length encoded (APPLE) Doppler OCT.

    Science.gov (United States)

    Wartak, Andreas; Haindl, Richard; Trasischker, Wolfgang; Baumann, Bernhard; Pircher, Michael; Hitzenberger, Christoph K

    2016-12-01

    We present a novel active-passive path-length encoded (APPLE) swept source Doppler optical coherence tomography (DOCT) approach, enabling three-dimensional velocity vector reconstruction of moving particles without prior knowledge of the orientation of motion. The developed APPLE DOCT setup allows for non-invasive blood flow measurements in vivo and was primarily designed for quantitative human ocular blood flow investigations. The system's performance was demonstrated by in vitro flow phantom as well as in vivo retinal vessel bifurcation measurements. Furthermore, total retinal blood flow - a biomarker aiding in diagnosis and monitoring of major ocular diseases such as glaucoma, diabetic retinopathy or central/branch retinal vein occlusion - was determined in the eyes of healthy human volunteers.

  5. Restoring the encoding properties of a stochastic neuron model by an exogenous noise

    Directory of Open Access Journals (Sweden)

    Alessandra ePaffi

    2015-05-01

    Full Text Available Here we evaluate the possibility of improving the encoding properties of an impaired neuronal system by superimposing an exogenous noise to an external electric stimulation signal. The approach is based on the use of mathematical neuron models consisting of stochastic HH-like circuit, where the impairment of the endogenous presynaptic inputs is described as a subthreshold injected current and the exogenous stimulation signal is a sinusoidal voltage perturbation across the membrane. Our results indicate that a correlated Gaussian noise, added to the sinusoidal signal can significantly increase the encoding properties of the impaired system, through the Stochastic Resonance (SR phenomenon. These results suggest that an exogenous noise, suitably tailored, could improve the efficacy of those stimulation techniques used in neuronal systems, where the presynaptic sensory neurons are impaired and have to be artificially bypassed.

  6. Improving Low Voltage Ride Through Capability of Wind Generators Using Dynamic Voltage Restorer

    Science.gov (United States)

    Sivasankar, Gangatharan; Suresh Kumar, Velu

    2014-08-01

    The increasing wind power integration with power grid has forced the situation to improve the reliability of wind generators for stable operation. One important problem with induction generator based wind farm is its low ride through capability to the grid voltage disturbance. Any disturbance such as voltage dip may cause wind farm outages. Since wind power contribution is in predominant percentage, such outages may lead to stability problem. The proposed strategy is to use dynamic voltage controller (DVR) to compensate the voltage disturbance. The DVR provides the wind generator the ability to remain connected in grid and improve the reliability. The voltage dips due to symmetrical and unsymmetrical faults are considered for analysis. The vector control scheme is employed for fault compensation which uses software phase locked loop scheme and park dq0 transformation technique. Extensive simulation results are included to illustrate the control and operation of DVR.

  7. Voltage control in active, intelligent low-voltage distribution networks; Spannungshaltung in aktiven, intelligenten Niederspannungsnetzen

    Energy Technology Data Exchange (ETDEWEB)

    Buelo, Thorsten; Mende, Denis [SMA Solar Technology AG, Niestetal (Germany); Geibel, Dominik [Fraunhofer Institut fuer Windenergie und Energiesystemtechnik (IWES), Kassel (Germany)] [and others

    2012-07-01

    This paper describes approaches for the voltage control in low-voltage distribution networks with a high share of distributed energy resources (DER). Taken into account are devices such as distribution transformers with on-load tap changer (OLTC), photovoltaic-inverters with reactive power capability and electronic voltage controllers (EVC). After a short description regarding voltage control, the devices and selected system concepts as well as the advantages and disadvantages of the different devices are described. Finally, the system-concepts are compared using the example of a real low voltage network, taking into account the possible increase of hosting capacity of the network, curtailing losses and the amount of reactive energy to be provided. (orig.)

  8. Energy Storage Options for Voltage Support in Low-Voltage Grids with High Penetration of Photovoltaic

    DEFF Research Database (Denmark)

    Marra, Francesco; Tarek Fawzy, Y.; Bülo, Thorsten

    2012-01-01

    The generation of power by photovoltaic (PV) systems is constantly increasing in low-voltage (LV) distribution grids, in line with the European environmental targets. To cope with the effects on grid voltage profiles during high generation and low demand periods, new solutions need to be establis......The generation of power by photovoltaic (PV) systems is constantly increasing in low-voltage (LV) distribution grids, in line with the European environmental targets. To cope with the effects on grid voltage profiles during high generation and low demand periods, new solutions need...... to be established. In the long term, these solutions should also aim to allow further more PV installed capacity, while meeting the power quality requirements. In this paper, different concepts of energy storage are proposed to ensure the voltage quality requirements in a LV grid with high PV penetration...

  9. Determination of the cathode fall voltage in fluorescent lamps by measurement of the operating voltage

    Energy Technology Data Exchange (ETDEWEB)

    Hilscher, A. [OSRAM GmbH, Augsburg (Germany)

    2002-07-21

    A new method for the determination of the cathode fall voltage of fluorescent lamps is shown. The cathode fall voltage can be determined by measurement of the lamp operating voltage at constant lamp wall temperature, constant discharge current and variation of the electrode heating current. Commercial lamps, which do not need to be specially prepared, can be used for the measurement. The results show good correlation to other measurements of the cathode fall voltage at various discharge currents by means of capacitive coupling. The measured values of the cathode fall voltage are used for determining the minimum, target and maximum setting of the sum of the squares of the pin currents of one electrode (the so-called SOS value) as a function of the discharge current in fluorescent lamp dimming. (author)

  10. Electrocardiogram voltage discordance: Interpretation of low QRS voltage only in the precordial leads.

    Science.gov (United States)

    Kim, Diana H; Verdino, Ralph J

    To define clinical correlates of low voltage isolated to precordial leads on the surface electrocardiogram (ECG). Low voltage (V) on the ECG is defined as QRS Vvoltage isolated to the precordial leads with normal limb lead voltages is unclear. Twelve-lead ECGs with QRS V>5mm in one or more limb leads and voltage was found in 256 of 150,000 ECGs (~0.2%). 50.4% of patients had discordant ECGs that correlated with classic etiologies, with a higher incidence of LV dilation in those with classic etiologies than those without. Low precordial voltage is associated with classic etiologies and LV dilation. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. On Secondary Control Approaches for Voltage Regulation in DC Microgrids

    DEFF Research Database (Denmark)

    Peyghami, Saeed; Mokhtari, Hossein; Davari, Pooya

    2017-01-01

    regulation on the load busses within a suitable range. Therefore, in addition to compensate the voltage drop of the primary controller, it is necessary to regulate the voltage of critical loads. In this paper, a new voltage regulation strategy is proposed to regulate the voltage of Micro-Grid (MG......Centralized or decentralized secondary controller is commonly employed to regulate the voltage drop raised by the primary controller. However, in the case of high capacity MGs and long feeders with much voltage drop on the line resistances, the conventional methods may not guarantee the voltage...

  12. A thermoelectric voltage effect in polyethylene oxide

    CERN Document Server

    Martin, B; Kliem, H

    2003-01-01

    The conductivity of polyethylene oxide (PEO) is described with a three-dimensional hopping model considering electrostatic interactions between the ions. Ions fluctuate over energy-barriers in a multi-well potential. To decide whether positive or negative charges are responsible for this conductivity, the thermoelectric voltage is measured. The samples are embedded between two aluminium-electrodes. The oxide on the interface between the electrodes and the PEO serves as a blocking layer. The temperature of each electrode is controlled by a Peltier element. A temperature step is applied to one electrode by changing the temperature of one of the Peltier elements. Due to this temperature gradient, the mobile charges fluctuate thermally activated from the warmer side to the colder side of the sample. The direction of the measured thermoelectric voltage indicates the type of mobile charges. It is found that positive charges are mobile. Further, it is shown that the absolute value of the thermoelectric voltage depen...

  13. Bias-voltage-controlled interlayer exchange coupling.

    Energy Technology Data Exchange (ETDEWEB)

    You, C.-Y.

    1999-03-29

    We propose a new system whose magnetization direction can be controlled by an applied bias voltage without an external magnetic field. The system consists of a four layered structure F{sub 1}/S/I/F{sub 2} (F{sub 1}, F{sub 2}: ferromagnets, S: spacer, I: insulator). An analytic expression for bias-voltage-controlled interlayer exchange coupling in this system is developed within a simple free-electron-like, one-dimensional approximation. According to the approach, the magnetic configurations of the two magnetic layers oscillate from antiferromagnetic to ferromagnetic with applied bias voltage. This implies that we can switch/rotate the magnetization direction without an external magnetic field. Possible applications of such a system are also discussed.

  14. A comprehensive review of dynamic voltage restorers

    DEFF Research Database (Denmark)

    Farhadi-Kangarlu, Mohammad; Babaei, Ebrahim; Blaabjerg, Frede

    2017-01-01

    will consider all of the fast voltage compensators, i.e. the devices called Static Series Compensator (SSC), sag corrector, Dynamic Sag Corrector (DySC), and other similar devices are also considered. All of these devices will be called DVR since they operate almost in the same way. Some comparative conclusions......During the last half century the Power Quality (PQ) related problems have become important issues. Many solutions have been proposed to address the PQ problems. The most attractive and flexible way is to use power electronic converter based devices such as Dynamic Voltage Restorer (DVR......), Distribution Static Compensator (DSTATCOM), Unified Power Quality Conditioner (UPQC), Uninterruptible Power Supply (UPS), and other devices usually called custom power devices. Among custom power devices, the DVR is the most economical solution to overcome the voltage-related PQ problems. Intensive research...

  15. Voltage control of cavity magnon polariton

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, S., E-mail: kaurs3@myumanitoba.ca; Rao, J. W.; Gui, Y. S.; Hu, C.-M., E-mail: hu@physics.umanitoba.ca [Department of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba R3T 2N2 (Canada); Yao, B. M. [Department of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba R3T 2N2 (Canada); National Laboratory for Infrared Physics, Chinese Academy of Sciences, Shanghai 200083 (China)

    2016-07-18

    We have experimentally investigated the microwave transmission of the cavity-magnon-polariton (CMP) generated by integrating a low damping magnetic insulator onto a 2D microwave cavity. The high tunability of our planar cavity allows the cavity resonance frequency to be precisely controlled using a DC voltage. By appropriately tuning the voltage and magnetic bias, we can observe the cavity photon magnon coupling and the magnetic coupling between a magnetostatic mode and the generated CMP. The dispersion of the generated CMP was measured by either tuning the magnetic field or the applied voltage. This electrical control of CMP may open up avenues for designing advanced on-chip microwave devices that utilize light-matter interaction.

  16. Semisupervised Community Detection by Voltage Drops

    Directory of Open Access Journals (Sweden)

    Min Ji

    2016-01-01

    Full Text Available Many applications show that semisupervised community detection is one of the important topics and has attracted considerable attention in the study of complex network. In this paper, based on notion of voltage drops and discrete potential theory, a simple and fast semisupervised community detection algorithm is proposed. The label propagation through discrete potential transmission is accomplished by using voltage drops. The complexity of the proposal is OV+E for the sparse network with V vertices and E edges. The obtained voltage value of a vertex can be reflected clearly in the relationship between the vertex and community. The experimental results on four real networks and three benchmarks indicate that the proposed algorithm is effective and flexible. Furthermore, this algorithm is easily applied to graph-based machine learning methods.

  17. Analysis of NSTX TF Joint Voltage Measurements

    Energy Technology Data Exchange (ETDEWEB)

    R, Woolley

    2005-10-07

    This report presents findings of analyses of recorded current and voltage data associated with 72 electrical joints operating at high current and high mechanical stress. The analysis goal was to characterize the mechanical behavior of each joint and thus evaluate its mechanical supports. The joints are part of the toroidal field (TF) magnet system of the National Spherical Torus Experiment (NSTX) pulsed plasma device operating at the Princeton Plasma Physics Laboratory (PPPL). Since there is not sufficient space near the joints for much traditional mechanical instrumentation, small voltage probes were installed on each joint and their voltage monitoring waveforms have been recorded on sampling digitizers during each NSTX ''shot''.

  18. Sensorless Control of IPMSM by Voltage Injection

    DEFF Research Database (Denmark)

    Matzen, Torben N.; Bech, Michael Møller

    2006-01-01

    In this paper a sensorless discrete current control of an Interior Permanent Magnet Synchrouns Motor (IPMSM) by voltage injection is designed and tested. The whole controller is operating in the dq-frame and for this reason the rotor position is essential to know, to transform between the station......In this paper a sensorless discrete current control of an Interior Permanent Magnet Synchrouns Motor (IPMSM) by voltage injection is designed and tested. The whole controller is operating in the dq-frame and for this reason the rotor position is essential to know, to transform between...... the stationary frame and the rotor xed dq-frame. To obtain the position even at standstill a sensorless scheme using voltage injection is added to the current controller....

  19. Voltage stability, bifurcation parameters and continuation methods

    Energy Technology Data Exchange (ETDEWEB)

    Alvarado, F.L. [Wisconsin Univ., Madison, WI (United States)

    1994-12-31

    This paper considers the importance of the choice of bifurcation parameter in the determination of the voltage stability limit and the maximum power load ability of a system. When the bifurcation parameter is power demand, the two limits are equivalent. However, when other types of load models and bifurcation parameters are considered, the two concepts differ. The continuation method is considered as a method for determination of voltage stability margins. Three variants of the continuation method are described: the continuation parameter is the bifurcation parameter the continuation parameter is initially the bifurcation parameter, but is free to change, and the continuation parameter is a new `arc length` parameter. Implementations of voltage stability software using continuation methods are described. (author) 23 refs., 9 figs.

  20. ESR melting under constant voltage conditions

    Energy Technology Data Exchange (ETDEWEB)

    Schlienger, M.E.

    1997-02-01

    Typical industrial ESR melting practice includes operation at a constant current. This constant current operation is achieved through the use of a power supply whose output provides this constant current characteristic. Analysis of this melting mode indicates that the ESR process under conditions of constant current is inherently unstable. Analysis also indicates that ESR melting under the condition of a constant applied voltage yields a process which is inherently stable. This paper reviews the process stability arguments for both constant current and constant voltage operation. Explanations are given as to why there is a difference between the two modes of operation. Finally, constant voltage process considerations such as melt rate control, response to electrode anomalies and impact on solidification will be discussed.

  1. CNFET Based Voltage Differencing Transconductance Amplifier

    Science.gov (United States)

    Laxya; Prasad, Dinesh; Mainuddin; Islam, S. S.

    2017-08-01

    In CMOS Technology basic Problem mainly includes dopant fluctuation, tunnelling effect and line edge roughness below 45nm technology. Carbon Nanotube based structures is better option for widen the Moore’s law due to its scalability channel electrostatics and higher mobility. In this manuscript we demonstrate an optimum design for linear property of CNTFET based VDTA at 32nm technology node. The proposed circuit consist of VDTA with CNTFET having two voltage input and two current outputs so that it works as voltage and transconductance operation to obtain the high performance. The minimum supply voltages of ±0.9V with 32nm technology mode are used. The CNTFET-VDTA performance is simulated on HSPICE. In this paper CNFET-based VDTA provides better results of DC transfer characteristics as compared with CMOS. All the simulation results are performed on HSPICE.

  2. Experimental validation of a high voltage pulse measurement method.

    Energy Technology Data Exchange (ETDEWEB)

    Cular, Stefan; Patel, Nishant Bhupendra; Branch, Darren W.

    2013-09-01

    This report describes X-cut lithium niobates (LiNbO3) utilization for voltage sensing by monitoring the acoustic wave propagation changes through LiNbO3 resulting from applied voltage. Direct current (DC), alternating current (AC) and pulsed voltage signals were applied to the crystal. Voltage induced shift in acoustic wave propagation time scaled quadratically for DC and AC voltages and linearly for pulsed voltages. The measured values ranged from 10 - 273 ps and 189 ps 2 ns for DC and non-DC voltages, respectively. Data suggests LiNbO3 has a frequency sensitive response to voltage. If voltage source error is eliminated through physical modeling from the uncertainty budget, the sensors U95 estimated combined uncertainty could decrease to ~0.025% for DC, AC, and pulsed voltage measurements.

  3. Investigation of digital hologram watermarking with double binary phase encoding

    Science.gov (United States)

    Zhou, Xiaohong; Chen, Linsen; Shao, Jie

    2005-02-01

    We propose a new method of digital watermarking with double binary optical phase encoding technique. Design procedures base on iterative Fourier transform algorithm (IFTA). The combination of two binary phase structures, in which one is used to encode the hidden image, and the other as encryption phase key, is inserted as watermark into the host image. The affections of phase levels of binary phase holograms on the quality of extracting watermark from the watermarked image have been analyzed, and results show that the 2/2 phase level combination is the best scheme of watermarking than other multiple combinations. The principle of encrypting the private key has been presented. This method can effectively increase the security of digital hologram watermarking and support the hard output of the watermarked image. The watermark is robust against hard output. We analysis the influence on the quality of extracted image after the processing of printing and scanning. We also develop the software tool for the watermarking process. The experimental results are given.

  4. Regulation of Voltage Gated K+ Channel KCNE1/KCNQ1 by the Janus Kinase JAK3

    Directory of Open Access Journals (Sweden)

    Jamshed Warsi

    2015-12-01

    Full Text Available Background/Aims: Janus kinase 3 (JAK3, a kinase mainly expressed in hematopoietic cells, has been shown to down-regulate the Na+/K+ ATPase and participate in the regulation of several ion channels and carriers. Channels expressed in thymus and regulating the abundance of T lymphocytes include the voltage gated K+ channel KCNE1/KCNQ1. The present study explored whether JAK3 contributes to the regulation of KCNE1/KCNQ1. Methods: cRNA encoding KCNE1/KCNQ1 was injected into Xenopus oocytes with or without additional injection of cRNA encoding wild-type JAK3, constitutively active A568VJAK3, or inactive K851AJAK3. Voltage gated K+ channel activity was measured utilizing two electrode voltage clamp. Results: KCNE1/KCNQ1 activity was significantly increased by wild-type JAK3 and A568VJAK3, but not by K851AJAK3. The difference between oocytes expressing KCNE1/KCNQ1 alone and oocytes expressing KCNE1/KCNQ1 with A568VJAK3 was virtually abrogated by JAK3 inhibitor WHI-P154 (22 µM but not by inhibition of transcription with actinomycin D (50 nM. Inhibition of KCNE1/KCNQ1 protein insertion into the cell membrane by brefeldin A (5 µM resulted in a decline of the voltage gated current, which was similar in the absence and presence of A568VJAK3, suggesting that A568VJAK3 did not accelerate KCNE1/KCNQ1 protein retrieval from the cell membrane. Conclusion: JAK3 contributes to the regulation of membrane KCNE1/KCNQ1 activity, an effect sensitive to JAK3 inhibitor WHI-P154.

  5. Regulation of Voltage Gated K+ Channel KCNE1/KCNQ1 by the Janus Kinase JAK3.

    Science.gov (United States)

    Warsi, Jamshed; Abousaab, Abeer; Fezai, Myriam; Elvira, Bernat; Lang, Florian

    2015-01-01

    Janus kinase 3 (JAK3), a kinase mainly expressed in hematopoietic cells, has been shown to down-regulate the Na+/K+ ATPase and participate in the regulation of several ion channels and carriers. Channels expressed in thymus and regulating the abundance of T lymphocytes include the voltage gated K+ channel KCNE1/KCNQ1. The present study explored whether JAK3 contributes to the regulation of KCNE1/KCNQ1. cRNA encoding KCNE1/KCNQ1 was injected into Xenopus oocytes with or without additional injection of cRNA encoding wild-type JAK3, constitutively active A568VJAK3, or inactive K851AJAK3. Voltage gated K+ channel activity was measured utilizing two electrode voltage clamp. KCNE1/KCNQ1 activity was significantly increased by wild-type JAK3 and A568VJAK3, but not by K851AJAK3. The difference between oocytes expressing KCNE1/KCNQ1 alone and oocytes expressing KCNE1/KCNQ1 with A568VJAK3 was virtually abrogated by JAK3 inhibitor WHI-P154 (22 µM) but not by inhibition of transcription with actinomycin D (50 nM). Inhibition of KCNE1/KCNQ1 protein insertion into the cell membrane by brefeldin A (5 µM) resulted in a decline of the voltage gated current, which was similar in the absence and presence of A568VJAK3, suggesting that A568VJAK3 did not accelerate KCNE1/KCNQ1 protein retrieval from the cell membrane. JAK3 contributes to the regulation of membrane KCNE1/KCNQ1 activity, an effect sensitive to JAK3 inhibitor WHI-P154. © 2015 The Author(s) Published by S. Karger AG, Basel.

  6. High-voltage test and measuring techniques

    CERN Document Server

    Hauschild, Wolfgang

    2014-01-01

    It is the intent of this book to combine high-voltage (HV) engineering with HV testing technique and HV measuring technique. Based on long-term experience gained by the authors as lecturer and researcher as well as member in international organizations, such as IEC and CIGRE, the book will reflect the state of the art as well as the future trends in testing and diagnostics of HV equipment to ensure a reliable generation, transmission and distribution of electrical energy. The book is intended not only for experts but also for students in electrical engineering and high-voltage engineering.

  7. Voltage control of DC islanded microgrids

    DEFF Research Database (Denmark)

    Tucci, Michele; Riverso, Stefano; Quintero, Juan Carlos Vasquez

    2015-01-01

    We propose a new decentralized control scheme for DC Islanded microGrids (ImGs) composed by several Distributed Generation Units (DGUs) with a general interconnection topology. Each local controller regulates to a reference value the voltage of the Point of Common Coupling (PCC) of the correspond......We propose a new decentralized control scheme for DC Islanded microGrids (ImGs) composed by several Distributed Generation Units (DGUs) with a general interconnection topology. Each local controller regulates to a reference value the voltage of the Point of Common Coupling (PCC...

  8. Interferometric Fiber-Optic Gyroscope

    Science.gov (United States)

    Depaula, Ramon P.; Bogert, Gail A.; Minford, William J.

    1990-01-01

    Integrated three-waveguide directional coupler functions as polarizer and splitter. Designed with transverse electric (TE) polarization in bar state (two coupling lengths) and transverse magnetic (TM) polarization in cross state (one coupling length). Intended for eventual fabrication as in mass-producible integrated optical circuit that provides advantages including low drive voltage, large-bandwidth phase modulation, preservation of polarization in transmission between devices on same substrate, and low cost.

  9. Frequency encoding in renal blood flow regulation

    DEFF Research Database (Denmark)

    Marsh, D.J.; Sosnovtseva, Olga; Pavlov, A.N.

    2005-01-01

    With a model of renal blood flow regulation, we examined consequences of tubuloglomerular feedback (TGF) coupling to the myogenic mechanism via voltage-gated Ca channels. The model reproduces the characteristic oscillations of the two mechanisms and predicts frequency and amplitude modulation...

  10. APPLICATION OF HIGH VOLTAGE DIVIDERS FOR POWER QUALITY INDICES MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Y. L. Anokhin

    2017-12-01

    Full Text Available Introduction. Determination of power quality indices in high-voltage power grids allows to find the reasons for the deterioration of the power quality. The relevant national and International Standards for power quality contain relevant norms of quality indices and requirements for their accuracy measurement. Problem. The most complicated part in the process of measuring the power quality indices at high voltage is the selection of the corresponding high-voltage scale voltage converters. Therefore, comparing the requirements of IEC 61000-4-30 to high voltage scale voltage converters is an important task. Goal. Analysis of the International Standard IEC 61000-4-30 requirements feasibility for measuring the indices of power quality in high-voltage electrical networks using different types of high-voltage scale voltage converters. Methodology. Comparison of the requirements of IEC 61000-4-30 Standard to high-voltage scale voltage converters, when measuring power quality indices, with the characteristics of high voltage electromagnetic transformers used in Ukraine, and with promising developments of high-voltage converters of other types. Results. It is shown in the study that in order to fulfill some of the requirements for class A of IEC 61000-4-30, the characteristics of electromagnetic voltage transformers should be determined in the substation conditions using mobile calibration high-voltage laboratories. To meet all the requirements for Class A IEC 61000-4-30, it is recommended to use broadband high-voltage dividers of resistive-capacitive type. Originality. In study it is shown firstly that all the requirements of the IEC 61000-4-30 Standard for high-voltage scale voltage converters can be performed on the basis of the use of broadband resistive-capacitive damped voltage dividers. Practical value. Expositions of specific types of resistive-capacitive high-voltage dividers are presented, their parameters are confirmed by the results of state

  11. An information theoretic characterisation of auditory encoding.

    Directory of Open Access Journals (Sweden)

    Tobias Overath

    2007-10-01

    Full Text Available The entropy metric derived from information theory provides a means to quantify the amount of information transmitted in acoustic streams like speech or music. By systematically varying the entropy of pitch sequences, we sought brain areas where neural activity and energetic demands increase as a function of entropy. Such a relationship is predicted to occur in an efficient encoding mechanism that uses less computational resource when less information is present in the signal: we specifically tested the hypothesis that such a relationship is present in the planum temporale (PT. In two convergent functional MRI studies, we demonstrated this relationship in PT for encoding, while furthermore showing that a distributed fronto-parietal network for retrieval of acoustic information is independent of entropy. The results establish PT as an efficient neural engine that demands less computational resource to encode redundant signals than those with high information content.

  12. Optical recording for investigating electrical defibrillation

    Science.gov (United States)

    Dillon, Stephen M.

    1994-05-01

    Optical recording uses a voltage-sensitive dye to transduce transmembrane cellular potential into a fluorescence, absorption or birefringence signal. Optical recording is useful for studying cardiac electrophysiology because it (1) is a non-contact method which spares fragile preparations mechanical damage, (2) can achieve sub-cellular spatial resolution, (3) allows acquisition of large numbers of simultaneous readings, and (4) is immune to artifacts produced by electrical shocks.

  13. Photoconductivity of high-voltage space insulating materials

    Science.gov (United States)

    Coffey, H. T.; Nanevicz, J. E.; Adamo, R. C.

    1975-01-01

    The dark and photoconductivities of four high voltage spacecraft insulators, Kapton-H, FEP Teflon, Parylene, and fused quartz, were studied under a variety of conditions intended to simulate a space environment. All measurements were made in a vacuum of less than .00001 torr while the temperature was varied from 22 C to 100 C. Some of the samples used employed conventional deposited metal electrodes--others employed electrodes composed either of an electron beam or a plasma formed by ionization of the residual gas in the test chamber. Test results show: (1) Kapton had unusual conduction properties; it conductivity decreased by more than an order of magnitude when heated at 100 C in a vacuum, but ultimately attained a stable and reproducible value. (2) Both Teflon and fused quartz had high dark resistivities but low photoresistivities when exposed to UV. Optical-density measurements revealed that both materials transmitted UV with little attenuation. (3) Parylene was found to have a low but relatively stable resistivity--comparatively minor changes occurred upon heating or illuminating the sample. Optical-density measurements showed that Parylene was absorbent in the UV and would prevent photoemission from the metal electrode on the back surface.

  14. Low-voltage and high-voltage TEM observations on MWCNTs of rat in vivo.

    Science.gov (United States)

    Sakaguchi, Norihito; Watari, Fumio; Yokoyama, Atsuro; Nodasaka, Yoshinobu; Ichinose, Hideki

    2009-01-01

    In the present study, we focused on the optimal conditions for observation of morphology and atomic structure of carbon nanotube (CNT) in vivo by transmission electron microscopy (TEM). Either low-voltage or high-voltage TEMs was chosen for the high-contrast or high-resolution imaging of subcutaneous tissue and the multi-wall CNT (MWCNT). The morphology and structure of each cell organelle were well recognized using the low-voltage TEM at 75 kV. Individual MWCNTs forming the cluster were also visible by the low-voltage TEM. On the contrary, the high-voltage TEM image at 1250 kV shows poor contrast on both the cell organelles and MWCNTs. However, graphene layers of MWCNT were clearly visible in the HRTEM image using the high-voltage TEM. The influence of the surrounding biological tissue can be disregarded by the high-energy electrons due to their weak scattering/absorption effect in the tissue. It was indicated that the usage of the high-voltage TEM is quite effective to the atomic structure analysis of nano-crystalline materials in vivo.

  15. Capturing power at higher voltages from arrays of microbial fuel cells without voltage reversal

    KAUST Repository

    Kim, Younggy

    2011-01-01

    Voltages produced by microbial fuel cells (MFCs) cannot be sustainably increased by linking them in series due to voltage reversal, which substantially reduces stack voltages. It was shown here that MFC voltages can be increased with continuous power production using an electronic circuit containing two sets of multiple capacitors that were alternately charged and discharged (every one second). Capacitors were charged in parallel by the MFCs, but linked in series while discharging to the circuit load (resistor). The parallel charging of the capacitors avoided voltage reversal, while discharging the capacitors in series produced up to 2.5 V with four capacitors. There were negligible energy losses in the circuit compared to 20-40% losses typically obtained with MFCs using DC-DC converters to increase voltage. Coulombic efficiencies were 67% when power was generated via four capacitors, compared to only 38% when individual MFCs were operated with a fixed resistance of 250 Ω. The maximum power produced using the capacitors was not adversely affected by variable performance of the MFCs, showing that power generation can be maintained even if individual MFCs perform differently. Longer capacitor charging and discharging cycles of up to 4 min maintained the average power but increased peak power by up to 2.6 times. These results show that capacitors can be used to easily obtain higher voltages from MFCs, allowing for more useful capture of energy from arrays of MFCs. © 2011 The Royal Society of Chemistry.

  16. Atmospheric effects on Quaternary polarization encoding for free space communication, laboratory simulation

    CERN Document Server

    Soorat, Ram

    2015-01-01

    We have simulated atmospheric effects such as fog and smoke in laboratory environment to simulate depolarisation due to atmospheric effects during a free space optical communi- cation. This has been used to study noise in two components of quaternary encoding for polarization shift keying. Individual components of a Quaternary encoding, such as vertical and horizontal as well as 45$^\\circ$ and 135$^\\circ$ , are tested separately and indicates that the depo- larization effects are different for these two situation. However, due to a differential method used to extract information bits, the protocol shows extremely low bit error rates. The information obtained is useful during deployment of a fully functional Quaternary encoded PolSK scheme in free space.

  17. Megahertz high voltage pulse generator suitable for capacitive load

    Science.gov (United States)

    Xu, Yu; Chen, Wei; Liang, Hao; Li, Yu-Huai; Liang, Fu-Tian; Shen, Qi; Liao, Sheng-Kai; Peng, Cheng-Zhi

    2017-11-01

    A high voltage pulse generator is presented to drive Pockels cell. The Pockels cell behaves like a capacitor which slows the rise/fall time of the pulse and restrains the repetition rate of the generator. To drive the Pockels cell applied in quantum communication system, it requires about 1 MHz repetition rate with the rise/fall time of the pulse less than 50 ns, adjustable amplitude up to 800 V and an adjustable duration. With the assistance of self-designed transformers, the circuits is simplified that a pair of high current radio frequency (RF) MOSFET drivers are employed to switch the power MOSFETs at a high speed, and the power MOSFETs shape the final output pulse with the requirements. From the tests, the generator can produce 800 V square pulses continously at 1 MHz rate with 46 ns in risetime and 31 ns in falltime when driving a 51 pF capacitive load. And the generator is now used to drive Pockels cell for encoding the polarization of photons.

  18. Megahertz high voltage pulse generator suitable for capacitive load

    Directory of Open Access Journals (Sweden)

    Yu Xu

    2017-11-01

    Full Text Available A high voltage pulse generator is presented to drive Pockels cell. The Pockels cell behaves like a capacitor which slows the rise/fall time of the pulse and restrains the repetition rate of the generator. To drive the Pockels cell applied in quantum communication system, it requires about 1 MHz repetition rate with the rise/fall time of the pulse less than 50 ns, adjustable amplitude up to 800 V and an adjustable duration. With the assistance of self-designed transformers, the circuits is simplified that a pair of high current radio frequency (RF MOSFET drivers are employed to switch the power MOSFETs at a high speed, and the power MOSFETs shape the final output pulse with the requirements. From the tests, the generator can produce 800 V square pulses continously at 1 MHz rate with 46 ns in risetime and 31 ns in falltime when driving a 51 pF capacitive load. And the generator is now used to drive Pockels cell for encoding the polarization of photons.

  19. Performance evaluation of automatic voltage regulators ...

    African Journals Online (AJOL)

    Performance of various Automatic Voltage Regulators (AVR's) in Nigeria and the causes of their inability to regulate at their set points have been investigated. The result indicates that the imported AVRs fail to give the 220 volts as displayed on the name plate at the specified low set point (such as 100, 120 volts etc) on ...

  20. Pulsed high voltage discharge induce hematologic changes

    African Journals Online (AJOL)

    STORAGESEVER

    2009-10-19

    Oct 19, 2009 ... The aim of this work to examine the effect of the gas-liquid hybrid discharge treatment system on some hematological ... liquid phase. The high energy plasma arc produces a pressure shock wave, electromagnetic radiations, .... through a 50 kilo-ohm resistor by a negative dc high-voltage power supply and ...

  1. Intermediate state trapping of a voltage sensor

    DEFF Research Database (Denmark)

    Lacroix, Jérôme J; Pless, Stephan Alexander; Maragliano, Luca

    2012-01-01

    transition pathway determined using the string method. The experimental results and computational analysis suggest that the phenotype of I241W may originate in the formation of a hydrogen bond between the indole nitrogen atom and the backbone carbonyl of R2. This work provides new information on intermediate...... states in voltage-gated ion channels with an approach that produces minimum chemical perturbation....

  2. Protection of Low Voltage CIGRE distribution Network

    DEFF Research Database (Denmark)

    Mustafa, Ghullam; Bak-Jensen, Birgitte; Bak, Claus Leth

    2013-01-01

    the inverters used for Photovoltaic (PV) and battery applications. The disconnection of the PV solar panels when in island mode is made by proposing switch dis-connecting devices. ABB is currently using these kinds of disconnection devices for the purpose of protecting solar panels against over voltages...

  3. PREDICTION OF VOLTAGE FLUCTUATION IN ELECTRIC GRIDS

    Directory of Open Access Journals (Sweden)

    V.A. Sapryka

    2013-06-01

    Full Text Available A mathematical model of voltage fluctuation versus parameters of power quality and power consumption is developed to allow predicting parameters of the power quality in electric grids. Application of the model will result in an electrical complex functioning optimization

  4. Stray voltage and milk quality: a review.

    Science.gov (United States)

    Reinemann, Douglas J

    2012-07-01

    If animal contact voltage reaches sufficient levels, animals coming into contact with grounded devices may receive a mild electric shock that can cause a behavioral response. At voltage levels that are just perceptible to the animal, behaviors indicative of perception (eg, flinches) may result with little change in normal routines. At higher exposure levels, avoidance behaviors may result. The direct effect of animal contact with electrical current can range from: • Mild behavioral reactions indicative of sensation, to • Involuntary muscle contraction, or twitching, to • Intense behavioral responses indicative of pain. The indirect effects of these behaviors can vary considerably depending on the specifics of the contact location, level of current flow, body pathway, frequency of occurrence, and many other factors related to the daily activities of animals. There are several common situations of concern in animal environments: • Animals avoiding certain exposure locations, which may result in: X Reduced water intake if exposure is required for animals to access watering devices, X Reduced feed intake if exposure is required for animals to accesses feeding devices or locations. • Difficulty of moving or handling animals in areas of voltage/current exposure• The physiologic implications of the release of stress hormones produced by contact with painful stimuli. The severity of response will depend on the amount of electrical current (measured in milliamps) flowing through the animal’s body, the pathway it takes through the body, and the sensitivity of the individual animal. The results of the combined current dose-response experiments, voltage exposure response experiments, and measurements of body and contact resistances is consistent with the lowest (worst case) cow + contact resistance as low as 500 as estimated by Lefcourt that may occur in some unusual situations on farms (firm application of the muzzle to a wet metallic watering device and hoof

  5. An Inexpensive Source of High Voltage

    Science.gov (United States)

    Saraiva, Carlos

    2012-01-01

    As a physics teacher I like recycling old apparatus and using them for demonstrations in my classes. In physics laboratories in schools, sources of high voltage include induction coils or electronic systems that can be bought from companies that sell lab equipment. But these sources can be very expensive. In this article, I will explain how you…

  6. Alternating current breakdown voltage of ice electret

    Science.gov (United States)

    Oshika, Y.; Tsuchiya, Y.; Okumura, T.; Muramoto, Y.

    2017-09-01

    Ice has low environmental impact. Our research objectives are to study the availability of ice as a dielectric insulating material at cryogenic temperatures. We focus on ferroelectric ice (iceXI) at cryogenic temperatures. The properties of iceXI, including its formation, are not clear. We attempted to obtain the polarized ice that was similar to iceXI under the applied voltage and cooling to 77 K. The polarized ice have a wide range of engineering applications as electronic materials at cryogenic temperatures. This polarized ice is called ice electret. The structural difference between ice electret and normal ice is only the positions of protons. The effects of the proton arrangement on the breakdown voltage of ice electret were shown because electrical properties are influenced by the structure of ice. We observed an alternating current (ac) breakdown voltage of ice electret and normal ice at 77 K. The mean and minimum ac breakdown voltage values of ice electret were higher than those of normal ice. We considered that the electrically weak part of the normal ice was improved by applied a direct electric field.

  7. Modeling and Simulation of Dynamic Voltage Restorer (DVR for Enhancing Voltage Sag

    Directory of Open Access Journals (Sweden)

    Amrita RAI

    2008-01-01

    Full Text Available The aim of this paper is to summaries the fundamental aspects of voltage sag production and their effects on power quality as well as enhancing this power quality in distribution network, using FACTS (Flexible AC Transmission System Devices i.e. Dynamic Voltage Restorer (DVR. DVR is a powerful custom power device for short duration voltage compensation, which is connected in series with the load & hence it possesses some advantages. (In this paper detailed modeling and simulation and analysis of the DVR device is presented.

  8. Analysis of Voltage Support by Electric Vehicles and Photovoltaic in a Real Danish Low Voltage Network

    DEFF Research Database (Denmark)

    Knezovic, Katarina; Marinelli, Mattia; Juul Møller, René

    2014-01-01

    With conventional generating units being replaced by renewable sources which are not required to provide same high level of ancillary services, there is an increasing need for additional resources to achieve certain standards regarding frequency and voltage. This paper investigates the potential ...... with addressing the issues regarding voltage control at the expense of increased loading. Analysed real Danish low voltage network has been modelled in Matlab SimPowerSystems and is based on consumption and PV production data measured individually for number of households....

  9. Grid Voltage Modulated Control of Grid-Connected Voltage Source Inverters under Unbalanced Grid Conditions

    DEFF Research Database (Denmark)

    Li, Mingshen; Gui, Yonghao; Quintero, Juan Carlos Vasquez

    2017-01-01

    In this paper, an improved grid voltage modulated control (GVM) with power compensation is proposed for grid-connected voltage inverters when the grid voltage is unbalanced. The objective of the proposed control is to remove the power ripple and to improve current quality. Three power compensation...... objectives are selected to eliminate the negative sequence components of currents. The modified GVM method is designed to obtain two separate second-order systems for not only the fast convergence rate of the instantaneous active and reactive powers but also the robust performance. In addition, this method...

  10. Simple and compact capacitive voltage probe for measuring voltage impulses up to 0.5 MV.

    Science.gov (United States)

    Pecquois, R; Pecastaing, L; de Ferron, A; Rivaletto, M; Pignolet, P; Novac, B M; Smith, I R; Adler, R J

    2012-03-01

    The paper describes a simple and compact 0.5 MV high-voltage capacitive probe developed in common by Université de Pau (France) and Loughborough University (UK). Design details are provided, together with a simple and straightforward methodology developed to assess the characteristics of high-voltage probes. The technique uses a 4 kV pulsed arrangement combined with results from a 2D electric field solver and a thorough PSpice circuit analysis. Finally, a practical example of high-voltage measurement performed using such a probe during the development phase of a high power microwave generator is provided.

  11. Modern optics

    CERN Document Server

    Guenther, B D

    2015-01-01

    Modern Optics is a fundamental study of the principles of optics using a rigorous physical approach based on Maxwell's Equations. The treatment provides the mathematical foundations needed to understand a number of applications such as laser optics, fiber optics and medical imaging covered in an engineering curriculum as well as the traditional topics covered in a physics based course in optics. In addition to treating the fundamentals in optical science, the student is given an exposure to actual optics engineering problems such as paraxial matrix optics, aberrations with experimental examples, Fourier transform optics (Fresnel-Kirchhoff formulation), Gaussian waves, thin films, photonic crystals, surface plasmons, and fiber optics. Through its many pictures, figures, and diagrams, the text provides a good physical insight into the topics covered. The course content can be modified to reflect the interests of the instructor as well as the student, through the selection of optional material provided in append...

  12. Roadmap on optical security

    Science.gov (United States)

    Javidi, Bahram; Carnicer, Artur; Yamaguchi, Masahiro; Nomura, Takanori; Pérez-Cabré, Elisabet; Millán, María S.; Nishchal, Naveen K.; Torroba, Roberto; Fredy Barrera, John; He, Wenqi; Peng, Xiang; Stern, Adrian; Rivenson, Yair; Alfalou, A.; Brosseau, C.; Guo, Changliang; Sheridan, John T.; Situ, Guohai; Naruse, Makoto; Matsumoto, Tsutomu; Juvells, Ignasi; Tajahuerce, Enrique; Lancis, Jesús; Chen, Wen; Chen, Xudong; Pinkse, Pepijn W. H.; Mosk, Allard P.; Markman, Adam

    2016-08-01

    : Sheridan reviews phase retrieval algorithms to perform different attacks, whereas Situ discusses nonlinear optical encryption techniques and the development of a rigorous optical information security theory. The fourth category with two contributions reports how encryption could be implemented at the nano- or micro-scale. Naruse discusses the use of nanostructures in security applications and Carnicer proposes encoding information in a tightly focused beam. In the fifth category, encryption based on ghost imaging using single-pixel detectors is also considered. In particular, the authors [Chen, Tajahuerce] emphasize the need for more specialized hardware and image processing algorithms. Finally, in the sixth category, Mosk and Javidi analyze in their corresponding papers how quantum imaging can benefit optical encryption systems. Sources that use few photons make encryption systems much more difficult to attack, providing a secure method for authentication.

  13. Voltage harmonic elimination with RLC based interface smoothing filter

    Science.gov (United States)

    Chandrasekaran, K.; Ramachandaramurthy, V. K.

    2015-04-01

    A method is proposed for designing a Dynamic Voltage Restorer (DVR) with RLC interface smoothing filter. The RLC filter connected between the IGBT based Voltage Source Inverter (VSI) is attempted to eliminate voltage harmonics in the busbar voltage and switching harmonics from VSI by producing a PWM controlled harmonic voltage. In this method, the DVR or series active filter produces PWM voltage that cancels the existing harmonic voltage due to any harmonic voltage source. The proposed method is valid for any distorted busbar voltage. The operating VSI handles no active power but only harmonic power. The DVR is able to suppress the lower order switching harmonics generated by the IGBT based VSI. Good dynamic and transient results obtained. The Total Harmonic Distortion (THD) is minimized to zero at the sensitive load end. Digital simulations are carried out using PSCAD/EMTDC to validate the performance of RLC filter. Simulated results are presented.

  14. Encoding and Decoding Procedures for Arrangements

    Directory of Open Access Journals (Sweden)

    Alexander A. Babaev

    2012-05-01

    Full Text Available This article discusses an algorithm based on the encoding procedure for representing a set of arrangement elements as a single number. Also the author provides the procedure for the inverse transformation of the code into arrangement elements. In addition the Article includes recommendations on the use of the above procedures in combinatorial algorithms of optimization.

  15. Encoders for block-circulant LDPC codes

    Science.gov (United States)

    Divsalar, Dariush (Inventor); Abbasfar, Aliazam (Inventor); Jones, Christopher R. (Inventor); Dolinar, Samuel J. (Inventor); Thorpe, Jeremy C. (Inventor); Andrews, Kenneth S. (Inventor); Yao, Kung (Inventor)

    2009-01-01

    Methods and apparatus to encode message input symbols in accordance with an accumulate-repeat-accumulate code with repetition three or four are disclosed. Block circulant matrices are used. A first method and apparatus make use of the block-circulant structure of the parity check matrix. A second method and apparatus use block-circulant generator matrices.

  16. Optimal Achievable Encoding for Brain Machine Interface

    Science.gov (United States)

    2017-12-22

    Brain - Machine Interface Eduardo Chichilnisky Leland Stanford Junior...Oct 2016 – 30 Sep 2017 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Optimal Achievable Encoding for Brain - Machine Interface 5b...Stanford Artificial Retina 15. SUBJECT TERMS Artificial retina, Retinal prosthesis, Brain - machine interface , Brain -computer interface ,

  17. Evaluative and Taxonomic Encoding in Children's Memory.

    Science.gov (United States)

    Kail, Robert V., Jr.; Schroll, John T.

    Two experiments were conducted to investigate the development of evaluative and taxonomic encoding in children's memory. The task used was a modification of the Wickens short-term memory task in which subjects' recall of words is tested following a distraction task. The first experiment found that 11-year-old children, but not 8-year-old children,…

  18. Visual Memory : The Price of Encoding Details

    NARCIS (Netherlands)

    Nieuwenstein, Mark; Kromm, Maria

    2017-01-01

    Studies on visual long-term memory have shown that we have a tremendous capacity for remembering pictures of objects, even at a highly detailed level. What remains unclear, however, is whether encoding objects at such a detailed level comes at any cost. In the current study, we examined how the

  19. Letter-Position Encoding and Dyslexia

    Science.gov (United States)

    Whitney, Carol; Cornelissen, Piers

    2005-01-01

    This article focuses on applying the SERIOL model of orthographic processing to dyslexia. The model is extended to include a phonological route and reading acquisition. We propose that the temporal alignment of serial orthographic and phonological representations is a key aspect of learning to read, driving the formation of a phonemic encoding.…

  20. Phenotypic and Molecular Characterization of Plasmid- Encoded ...

    African Journals Online (AJOL)

    Purpose: To investigate the distribution of plasmid-encoded extended spectrum beta-lacatamases (ESBLs) in Lahore, Pakistan using different phenotypic and molecular methods. Methods: Escherichia coli and Klebsiella spp were obtained over a period of nineteen months (June 2007 to December 2008). Both were tested ...

  1. Encoding of tactile stimuli by mechanoreceptors and interneurons of the medicinal leech

    Directory of Open Access Journals (Sweden)

    Jutta Kretzberg

    2016-10-01

    Full Text Available For many animals processing of tactile information is a crucial task in behavioral contexts like exploration, foraging and stimulus avoidance. The leech, having infrequent access to food, developed an energy efficient reaction to tactile stimuli, avoiding unnecessary muscle movements: The local bend behavior moves only a small part of the body wall away from an object touching the skin, while the rest of the animal remains stationary. Amazingly, the precision of this localized behavioral response is similar to the spatial discrimination threshold of the human fingertip, although the leech skin is innervated by an order of magnitude fewer mechanoreceptors and each midbody ganglion contains only 400 individually identified neurons in total. Prior studies suggested that this behavior is controlled by a three-layered feed-forward network, consisting of four mechanoreceptors (P cells, approximately 20 interneurons and 10 individually characterized motor neurons, all of which encode tactile stimulus location by overlapping, symmetrical tuning curves. Additionally, encoding of mechanical force was attributed to three types of mechanoreceptors reacting to distinct intensity ranges: T cells for touch, P cells for pressure and N cells for strong, noxious skin stimulation. In this study, we provide evidences that tactile stimulus encoding in the leech is more complex than previously thought. Combined electrophysiological, anatomical and voltage sensitive dye approaches indicate that P and T cells both play a major role in tactile information processing resulting in local bending. Our results indicate that tactile encoding neither relies on distinct force intensity ranges of different cell types, nor location encoding is restricted to spike count tuning. Instead, we propose that P and T cells form a mixed type population, which simultaneously employs temporal response features and spike counts for multiplexed encoding of touch location and force intensity

  2. Dynamic array of dark optical traps

    DEFF Research Database (Denmark)

    Daria, V.R.; Rodrigo, P.J.; Glückstad, J.

    2004-01-01

    A dynamic array of dark optical traps is generated for simultaneous trapping and arbitrary manipulation of multiple low-index microstructures. The dynamic intensity patterns forming the dark optical trap arrays are generated using a nearly loss-less phase-to-intensity conversion of a phase......-encoded coherent light source. Two-dimensional input phase distributions corresponding to the trapping patterns are encoded using a computer-programmable spatial light modulator, enabling each trap to be shaped and moved arbitrarily within the plane of observation. We demonstrate the generation of multiple dark...

  3. Phase recovering algorithms for extended objects encoded in digitally recorded holograms

    Directory of Open Access Journals (Sweden)

    Peng Z.

    2010-06-01

    Full Text Available The paper presents algorithms to recover the optical phase of digitally encoded holograms. Algorithms are based on the use of a numerical spherical reconstructing wave. Proof of the validity of the concept is performed through an experimental off axis digital holographic set-up. Two-color digital holographic reconstruction is also investigated. Application of the color set-up and algorithms concerns the simultaneous two-dimensional deformation measurement of an object submitted to a mechanical loading.

  4. KillerOrange, a Genetically Encoded Photosensitizer Activated by Blue and Green Light

    OpenAIRE

    Karen S Sarkisyan; Zlobovskaya, Olga A.; Gorbachev, Dmitry A.; Bozhanova, Nina G.; Sharonov, George V.; Staroverov, Dmitriy B; Egorov, Evgeny S.; Ryabova, Anastasia V.; Solntsev, Kyril M.; Alexander S. Mishin; Lukyanov, Konstantin A.

    2015-01-01

    Genetically encoded photosensitizers, proteins that produce reactive oxygen species when illuminated with visible light, are increasingly used as optogenetic tools. Their applications range from ablation of specific cell populations to precise optical inactivation of cellular proteins. Here, we report an orange mutant of red fluorescent protein KillerRed that becomes toxic when illuminated with blue or green light. This new protein, KillerOrange, carries a tryptophan-based chromophore that is...

  5. How Attention Modulates Encoding of Dynamic Stimuli

    Directory of Open Access Journals (Sweden)

    Noga Oren

    2016-10-01

    Full Text Available When encoding a real-life, continuous stimulus, the same neural circuits support processing and integration of prior as well as new incoming information. This ongoing interplay is modulated by attention, which is evident in the prefrontal cortex sections of the task positive network (TPN, and in the posterior cingulate cortex (PCC, a hub of the default mode network (DMN. Yet the exact nature of such modulation is still unclear. To investigate this issue, we utilized an fMRI task that employed movies as the encoded stimuli and manipulated attentional load via an easy or hard secondary task that was performed simultaneously with encoding. Results showed increased intersubject correlation (inter-SC levels when encoding movies in a condition of high, as compared to low attentional load. This was evident in bilateral ventrolateral and dorsomedial prefrontal cortices and the dorsal PCC (dPCC. These regions became more attuned to the combination of the movie and the secondary task as the attentional demand of the task increased. Activation analyses revealed that at higher load the frontal TPN regions were more activated, whereas the dPCC was more deactivated. Attentional load also influenced connectivity within and between the networks. At high load the dPCC was anti-correlated to the frontal regions, which were more functionally coherent amongst themselves. Finally and critically, greater inter-SC in the dPCC at high load during encoding predicted lower memory strength when that information was retrieved. This association between inter-SC levels and memory strength suggest that as attentional demands increased, the dPCC was more attuned to the secondary task at the expense of the encoded stimulus, thus weakening memory for the encoded stimulus. Together, our findings show that attentional load modulated the function of core TPN and DMN regions. Furthermore, the observed correlation between memory strength and the modulation of the dPCC points to this

  6. Design of high-speed optical transmission module with an integrated Ti:Er:LiNbO3 waveguide laser/ LiNbO3 electro-optic modulator

    Science.gov (United States)

    Bai, Yang; Chen, Shufen; Fu, Li; Fang, Wei; Lu, Junjun

    2005-01-01

    A high bit rate more than 10Gbit/s optical pulse generation device is the key to achieving high-speed and broadband optical fiber communication network system .Now, we propose a novel high-speed optical transmission module(TM) consisting of a Ti:Er:LiNbO3 waveguide laser and a Mach-Zehnder-type encoding modulator on the same Er-doped substrate. According to the standard of ITU-T, we design the 10Gbit/ s transmission module at 1.53μm on the Z cut Y propagation LiNbO3 slice. A dynamic model and the corresponding numerical code are used to analyze the waveguide laser while the electrooptic effect to design the modulator. Meanwhile, the working principle, key technology, typical characteristic parameters of the module are given. The transmission module has a high extinction ratio and a low driving voltage, which supplies the efficient, miniaturized light source for wavelength division multiplexing(WDM) system. In additional, the relation of the laser gain with the cavity parameter, as well as the relation of the bandwidth of the electrooptic modulator with some key factors are discussed .The designed module structure is simulated by BPM software and HFSS software.

  7. Conservation voltage regulation (CVR) applied to energy savings by voltage-adjusting equipment through AMI

    Science.gov (United States)

    Lan, B.-R.; Chang, C.-A.; Huang, P.-Y.; Kuo, C.-H.; Ye, Z.-J.; Shen, B.-C.; Chen, B.-K.

    2017-11-01

    Conservation voltage reduction (CVR) includes peak demand reduction, energy conservation, carbon emission reduction, and electricity bill reduction. This paper analyzes the energy-reduction of Siwei Feeders with applying CVR, which are situated in Penghu region and equipped with smart meters. Furthermore, the applicable voltage reduction range for the feeders will be explored. This study will also investigate how the CVR effect and energy conservation are improved with the voltage control devices integrated. The results of this study can serve as a reference for the Taiwan Power Company to promote and implement voltage reduction and energy conservation techniques. This study is expected to enhance the energy-reduction performance of the Penghu Low Carbon Island Project.

  8. Analysis and Mathematical Model for Restitution of Voltage Using Dynamic Voltage Restorer

    Directory of Open Access Journals (Sweden)

    C. Gopinath

    2014-01-01

    Full Text Available Voltage sag and swell have a major concern in the distribution systems. In order to mitigate the voltage sag and swell, a custom power device called dynamic voltage restorer (DVR is used. The proposed system is a polymer electrolyte membrane (PEM fuel cell based DVR. The energy from the fuel cell is stored in the super capacitor to restitute the voltage. In this proposed DVR, Z-source inverter is used instead of traditional inverter because of buck-boost and shoot through capability. The simulation is performed using three controller topologies: PI controller, synchronous reference frame controller and fuzzy controller and the results are verified using Matlab-Simulink environment.

  9. Impact of Voltage Conditions on Distributed Generation Connectivity in Medium Voltage Grids

    Directory of Open Access Journals (Sweden)

    Ireneusz Grządzielski

    2015-12-01

    Full Text Available A significant increase in the distributed generating sources connected and planned for connection to medium voltage (MV grids makes voltage criteria very important in assessing the sources’ connectivity. Many requests have been submitted for connection of distributed generation sources at a considerable distance (even a dozen or so kilometres from a main supply substation’s MV buses. As a rule, these are requests for the interconnection deep in an existing MV bus, but also directly to MV switching substation bays. Then maintaining appropriate voltage levels becomes a basic technical problem. Another technical problem relates to meeting the power quality criteria. THD index, and the level of individual harmonics, significantly increases, in many cases reaching or even exceeding the boundary values. With their extensive experience, the authors present examples and results of some analyses herewith. They indicate the impact of voltage conditions on the connection possibilities of distributed generation to MV grids.

  10. Structure of the voltage-gated K+ channel Eag1 reveals an alternative voltage sensing mechanism

    Science.gov (United States)

    Whicher, Jonathan R.; MacKinnon, Roderick

    2017-01-01

    Voltage-gated potassium channels (Kv) are gated by the movement of the transmembrane voltage sensor, which is coupled, through the helical S4–S5 linker, to the potassium pore. We determined the single-particle cryo-EM structure of mammalian Kv10.1 or Eag1, bound to the channel inhibitor calmodulin, at 3.78Å resolution. Unlike previous Kv structures, the S4–S5 linker of Eag1 is a 5-residue loop and the transmembrane segments are not domain swapped, suggesting an alternative mechanism of voltage-dependent gating. Additionally, the structure and position of the S4–S5 linker allows calmodulin to bind to the intracellular domains and close the potassium pore independent of voltage sensor position. The structure reveals an alternative gating mechanism for Kv channels and provides a template to further understand the gating properties of Eag1 and related channels. PMID:27516594

  11. Distribution System Voltage Regulation by Distributed Energy Resources

    Energy Technology Data Exchange (ETDEWEB)

    Ceylan, Oguzhan [ORNL; Liu, Guodong [ORNL; Xu, Yan [ORNL; Tomsovic, Kevin [University of Tennessee, Knoxville (UTK)

    2014-01-01

    This paper proposes a control method to regulate voltages in 3 phase unbalanced electrical distribution systems. A constrained optimization problem to minimize voltage deviations and maximize distributed energy resource (DER) active power output is solved by harmony search algorithm. IEEE 13 Bus Distribution Test System was modified to test three different cases: a) only voltage regulator controlled system b) only DER controlled system and c) both voltage regulator and DER controlled system. The simulation results show that systems with both voltage regulators and DER control provide better voltage profile.

  12. A new encoding scheme for visible light communications with applications to mobile connections

    Science.gov (United States)

    Benton, David M.; St. John Brittan, Paul

    2017-10-01

    A new, novel and unconventional encoding scheme called concurrent coding, has recently been demonstrated and shown to offer interesting features and benefits in comparison to conventional techniques, such as robustness against burst errors and improved efficiency of transmitted power. Free space optical communications can suffer particularly from issues of alignment which requires stable, fixed links to be established and beam wander which can interrupt communications. Concurrent coding has the potential to help ease these difficulties and enable mobile, flexible optical communications to be implemented through the use of a source encoding technique. This concept has been applied for the first time to optical communications where standard light emitting diodes (LEDs) have been used to transmit information encoded with concurrent coding. The technique successfully transmits and decodes data despite unpredictable interruptions to the transmission causing significant drop-outs to the detected signal. The technique also shows how it is possible to send a single block of data in isolation with no pre-synchronisation required between transmitter and receiver, and no specific synchronisation sequence appended to the transmission. Such systems are robust against interference - intentional or otherwise - as well as intermittent beam blockage.

  13. Increasing Integration of Wind Power in Medium Voltage Grid by Voltage Support of Smart Transformer

    OpenAIRE

    Gao, Xiang; De Carne, Giovanni; Liserre, Marco; Vournas, Costas

    2016-01-01

    The voltage rise during wind energy penetration represents a limit of the wind power integration in the distribution grid. The Smart Transformer (ST), a power electronics-based transformer, can provide additional services to the distribution grids, for instance the voltage support in MV grid by means of reactive power injection. In this paper, this service is applied to increase the hosting capacity of wind power in MV grids.

  14. Impact of Voltage Conditions on Distributed Generation Connectivity in Medium Voltage Grids

    OpenAIRE

    Ireneusz Grządzielski; Krzysztof Marszałkiewicz; Andrzej Trzeciak

    2015-01-01

    A significant increase in the distributed generating sources connected and planned for connection to medium voltage (MV) grids makes voltage criteria very important in assessing the sources’ connectivity. Many requests have been submitted for connection of distributed generation sources at a considerable distance (even a dozen or so kilometres) from a main supply substation’s MV buses. As a rule, these are requests for the interconnection deep in an existing MV bus, but also directly to MV sw...

  15. Engineering Optics

    CERN Document Server

    Iizuka, Keigo

    2008-01-01

    Engineering Optics is a book for students who want to apply their knowledge of optics to engineering problems, as well as for engineering students who want to acquire the basic principles of optics. It covers such important topics as optical signal processing, holography, tomography, holographic radars, fiber optical communication, electro- and acousto-optic devices, and integrated optics (including optical bistability). As a basis for understanding these topics, the first few chapters give easy-to-follow explanations of diffraction theory, Fourier transforms, and geometrical optics. Practical examples, such as the video disk, the Fresnel zone plate, and many more, appear throughout the text, together with numerous solved exercises. There is an entirely new section in this updated edition on 3-D imaging.

  16. Intelligent Distribution Voltage Control with Distributed Generation =

    Science.gov (United States)

    Castro Mendieta, Jose

    In this thesis, three methods for the optimal participation of the reactive power of distributed generations (DGs) in unbalanced distributed network have been proposed, developed, and tested. These new methods were developed with the objectives of maintain voltage within permissible limits and reduce losses. The first method proposes an optimal participation of reactive power of all devices available in the network. The propose approach is validated by comparing the results with other methods reported in the literature. The proposed method was implemented using Simulink of Matlab and OpenDSS. Optimization techniques and the presentation of results are from Matlab. The co-simulation of Electric Power Research Institute's (EPRI) OpenDSS program solves a three-phase optimal power flow problem in the unbalanced IEEE 13 and 34-node test feeders. The results from this work showed a better loss reduction compared to the Coordinated Voltage Control (CVC) method. The second method aims to minimize the voltage variation on the pilot bus on distribution network using DGs. It uses Pareto and Fuzzy-PID logic to reduce the voltage variation. Results indicate that the proposed method reduces the voltage variation more than the other methods. Simulink of Matlab and OpenDSS is used in the development of the proposed approach. The performance of the method is evaluated on IEEE 13-node test feeder with one and three DGs. Variables and unbalanced loads are used, based on real consumption data, over a time window of 48 hours. The third method aims to minimize the reactive losses using DGs on distribution networks. This method analyzes the problem using the IEEE 13-node test feeder with three different loads and the IEEE 123-node test feeder with four DGs. The DGs can be fixed or variables. Results indicate that integration of DGs to optimize the reactive power of the network helps to maintain the voltage within the allowed limits and to reduce the reactive power losses. The thesis is

  17. High pressure optical combustion probe

    Energy Technology Data Exchange (ETDEWEB)

    Woodruff, S.D.; Richards, G.A.

    1995-06-01

    The Department of Energy`s Morgantown Energy Technology Center has developed a combustion probe for monitoring flame presence and heat release. The technology involved is a compact optical detector of the OH radical`s UV fluorescence. The OH Monitor/Probe is designed to determine the flame presence and provide a qualitative signal proportional to the flame intensity. The probe can be adjusted to monitor a specific volume in the combustion zone to track spatial fluctuations in the flame. The probe is capable of nanosecond time response and is usually slowed electronically to fit the flame characteristics. The probe is a sapphire rod in a stainless steel tube which may be inserted into the combustion chamber and pointed at the flame zone. The end of the sapphire rod is retracted into the SS tube to define a narrow optical collection cone. The collection cone may be adjusted to fit the experiment. The fluorescence signal is collected by the sapphire rod and transmitted through a UV transmitting, fused silica, fiber optic to the detector assembly. The detector is a side window photomultiplier (PMT) with a 310 run line filter. A Hamamatsu photomultiplier base combined with a integral high voltage power supply permits this to be a low voltage device. Electronic connections include: a power lead from a modular DC power supply for 15 VDC; a control lead for 0-1 volts to control the high voltage level (and therefore gain); and a lead out for the actual signal. All low voltage connections make this a safe and easy to use device while still delivering the sensitivity required.

  18. Electron optics

    CERN Document Server

    Grivet, Pierre; Bertein, F; Castaing, R; Gauzit, M; Septier, Albert L

    1972-01-01

    Electron Optics, Second English Edition, Part I: Optics is a 10-chapter book that begins by elucidating the fundamental features and basic techniques of electron optics, as well as the distribution of potential and field in electrostatic lenses. This book then explains the field distribution in magnetic lenses; the optical properties of electrostatic and magnetic lenses; and the similarities and differences between glass optics and electron optics. Subsequent chapters focus on lens defects; some electrostatic lenses and triode guns; and magnetic lens models. The strong focusing lenses and pris

  19. Optical Tunable-Based Transmitter for Multiple Radio Frequency Bands

    Science.gov (United States)

    Nguyen, Hung (Inventor); Simons, Rainee N. (Inventor); Wintucky, Edwin G. (Inventor); Freeman, Jon C. (Inventor)

    2016-01-01

    An optical tunable transmitter is used to transmit multiple radio frequency bands on a single beam. More specifically, a tunable laser is configured to generate a plurality of optical wavelengths, and an optical tunable transmitter is configured to modulate each of the plurality of optical wavelengths with a corresponding radio frequency band. The optical tunable transmitter is also configured to encode each of the plurality of modulated optical wavelengths onto a single laser beam for transmission of a plurality of radio frequency bands using the single laser beam.

  20. Modeling and control of threshold voltage based on pull-in characteristic for micro self-locked switch

    Science.gov (United States)

    Deng, Jufeng; Hao, Yongping; Liu, Shuangjie

    2017-09-01

    Micro self-locked switches (MSS), where execution voltage corresponds to the output signal, are efficient and convenient platforms for sensor applications. The proper functioning of these sensing devices requires driving accurate displacement under execution voltage. In this work, we show how to control the actuating properties of MSSS. This switch comprises microstructures of various shapes with dimensions from 3.5 to 180 μm, which are optimized to encode a desired manufacture deviation by means of mathematical model of threshold voltage. Compared with pull-in voltage, threshold voltage is more easy to control the pull-in instability point by theoretical analysis. With the help of advanced manufacture technology, switch is processed in accordance with the proposed control method. Then, experimental results show that it is better, which have been validated by corresponding experiments. In addition, they can be known from experiments that the manufacturing technology is advanced and feasible, and its high resilience and stably self-locked function can achieve instantaneously sensing.

  1. Annealing of silicon optical fibers

    Science.gov (United States)

    Gupta, N.; McMillen, C.; Singh, R.; Podila, R.; Rao, A. M.; Hawkins, T.; Foy, P.; Morris, S.; Rice, R.; Poole, K. F.; Zhu, L.; Ballato, J.

    2011-11-01

    The recent realization of silicon core optical fibers has the potential for novel low insertion loss rack-to-rack optical interconnects and a number of other uses in sensing and biomedical applications. To the best of our knowledge, incoherent light source based rapid photothermal processing (RPP) was used for the first time to anneal glass-clad silicon core optical fibers. X-ray diffraction examination of the silicon core showed a considerable enhancement in the length and amount of single crystallinity post-annealing. Further, shifts in the Raman frequency of the silicon in the optical fiber core that were present in the as-drawn fibers were removed following the RPP treatment. Such results indicate that the RPP treatment increases the local crystallinity and therefore assists in the reduction of the local stresses in the core, leading to more homogenous fibers. The dark current-voltage characteristics of annealed silicon optical fiber diodes showed lower leakage current than the diodes based on as-drawn fibers. Photons in UV and vacuum ultraviolet (VUV) regions play a very important role in improving the bulk and carrier transport properties of RPP-treated silicon optical fibers, and the resultant annealing permits a path forward to in situ enhancement of the structure and properties of these new crystalline core optical fibers.

  2. Electronic Voltage and Current Transformers Testing Device

    Directory of Open Access Journals (Sweden)

    Yong Xiao

    2012-01-01

    Full Text Available A method for testing electronic instrument transformers is described, including electronic voltage and current transformers (EVTs, ECTs with both analog and digital outputs. A testing device prototype is developed. It is based on digital signal processing of the signals that are measured at the secondary outputs of the tested transformer and the reference transformer when the same excitation signal is fed to their primaries. The test that estimates the performance of the prototype has been carried out at the National Centre for High Voltage Measurement and the prototype is approved for testing transformers with precision class up to 0.2 at the industrial frequency (50 Hz or 60 Hz. The device is suitable for on-site testing due to its high accuracy, simple structure and low-cost hardware.

  3. Electronic voltage and current transformers testing device.

    Science.gov (United States)

    Pan, Feng; Chen, Ruimin; Xiao, Yong; Sun, Weiming

    2012-01-01

    A method for testing electronic instrument transformers is described, including electronic voltage and current transformers (EVTs, ECTs) with both analog and digital outputs. A testing device prototype is developed. It is based on digital signal processing of the signals that are measured at the secondary outputs of the tested transformer and the reference transformer when the same excitation signal is fed to their primaries. The test that estimates the performance of the prototype has been carried out at the National Centre for High Voltage Measurement and the prototype is approved for testing transformers with precision class up to 0.2 at the industrial frequency (50 Hz or 60 Hz). The device is suitable for on-site testing due to its high accuracy, simple structure and low-cost hardware.

  4. High-voltage multijunction photovoltaic solar cell

    Energy Technology Data Exchange (ETDEWEB)

    Doroshenko, V.G.; Zaks, M.B.; Kalash' yan, V.A.; Lozovskiy, V.N.; Skokov, Yu.V.; Solodukha, O.I.

    1979-01-01

    The possibility of developing a high-voltage multijunction photovoltaic cell (HMPC) based on a single crystal with multiple vertical p-n junctions formed by heavily doped zones at right angles to the illuminated surface of the instrument is demonstrated. A laboratory technology for producing HMPC based on the zone recrystallization method with a temperature gradient and linear zones is presented. The investigated variant of HMPC was made of n-type silicon with resistivity of 1 ohm.cm in which are formed vertical p/sup +/ type zones doped with aluminum or an aluminum-boron alloy. The performance HMPC (with 11 and 5 vertical p-n junctions) was experimentally investigated in the presence of 400 to 500 ms light pulses from a xenon lamp with a near-solar spectrum and the current-voltage characteristic of the HMPC was found to be then virtually unaffected.

  5. Electrical system architecture having high voltage bus

    Science.gov (United States)

    Hoff, Brian Douglas [East Peoria, IL; Akasam, Sivaprasad [Peoria, IL

    2011-03-22

    An electrical system architecture is disclosed. The architecture has a power source configured to generate a first power, and a first bus configured to receive the first power from the power source. The architecture also has a converter configured to receive the first power from the first bus and convert the first power to a second power, wherein a voltage of the second power is greater than a voltage of the first power, and a second bus configured to receive the second power from the converter. The architecture further has a power storage device configured to receive the second power from the second bus and deliver the second power to the second bus, a propulsion motor configured to receive the second power from the second bus, and an accessory motor configured to receive the second power from the second bus.

  6. Supply Voltage Glitches Effects on CMOS Circuits

    OpenAIRE

    Djellid-Ouar, Anissa; Cathébras, Guy; Bancel, Frédéric

    2006-01-01

    International audience; Among the attacks applied on secure circuits, fault injection techniques consist in the use of a combination of environmental conditions that induce computational errors in the chip that can leak protected informations. The purpose of our study is to build an accurate model able to describe the behaviour of CMOS circuits in presence of deliberated short supply voltage variations. This behaviour depends strongly on the basic gates (combinational logic, registers. . . ) ...

  7. Voltage Control of Spin Waves in Nanostructures

    OpenAIRE

    Chen, Yu-Jin

    2017-01-01

    This dissertation describes the experiments that investigate new methods to control spin waves by electric field. In one experiment, we excite parametric resonance of magnetization in nanoscale magnetic tunnel junctions, which are multilayer thin film devices patterned into nanopillar shape. One of the layers possesses strong perpendicular magnetic anisotropy and exhibits strong voltage-controlled magnetic anisotropy. This magneto-electric effect allows one to modulate the perpendicular magne...

  8. Printing low-voltage dielectric elastomer actuators

    Science.gov (United States)

    Poulin, Alexandre; Rosset, Samuel; Shea, Herbert R.

    2015-12-01

    We demonstrate the fabrication of fully printed thin dielectric elastomer actuators (DEAs), reducing the operation voltage below 300 V while keeping good actuation strain. DEAs are soft actuators capable of strains greater than 100% and response times below 1 ms, but they require driving voltage in the kV range, limiting the possible applications. One way to reduce the driving voltage of DEAs is to decrease the dielectric membrane thickness, which is typically in the 20-100 μm range, as reliable fabrication becomes challenging below this thickness. We report here the use of pad-printing to produce μm thick silicone membranes, on which we pad-print μm thick compliant electrodes to create DEAs. We achieve a lateral actuation strain of 7.5% at only 245 V on a 3 μm thick pad-printed membrane. This corresponds to a ratio of 125%/kV2, by far the highest reported value for DEAs. To quantify the increasing stiffening impact of the electrodes on DEA performance as the membrane thickness decreases, we compare two circular actuators, one with 3 μm- and one with 30 μm-thick membranes. Our experimental measurements show that the strain uniformity of the 3 μm-DEA is indeed affected by the mechanical impact of the electrodes. We developed a simple DEA model that includes realistic electrodes of finite stiffness, rather than assuming zero stiffness electrodes as is commonly done. The simulation results confirm that the stiffening impact of the electrodes is an important parameter that should not be neglected in the design of thin-DEAs. This work presents a practical approach towards low-voltage DEAs, a critical step for the development of real world applications.

  9. Multiagent voltage and reactive power control system

    Directory of Open Access Journals (Sweden)

    I. Arkhipov

    2014-12-01

    Full Text Available This paper is devoted to the research of multiagent voltage and reactive power control system development. The prototype of the system has been developed by R&D Center at FGC UES (Russia. The control system architecture is based on the innovative multiagent system theory application that leads to the achievement of several significant advantages (in comparison to traditional control systems implementation such as control system efficiency enhancement, control system survivability and cyber security.

  10. DC Voltage Interface Standards for Naval Applications

    Science.gov (United States)

    2015-06-24

    from MIL-STD-1399 Section 300b. • Maximum Load Line-to-Ground Capacitance : The maximum line to ground capacitance from each terminal of the load...conversion equipment or switchgear) may have a length limit to prevent excessive voltage drop due to the cable inductance when subjected to a high power...excursion. Sonar and radar are cited as examples of this type of power user. The magnitude of the pulse is presumably uniform. In [1] and [2], a

  11. Autonomous Operation of Low Voltage Microgrids

    Directory of Open Access Journals (Sweden)

    Irena Wasiak

    2014-12-01

    Full Text Available The article describes the possibilities of LV microgrids operation in the island mode. Control strategies of energy sources connected to the grid by means of invertors are discussed, either for a microgrid connected to the supplying network or during the island mode operation. The presented results of research were conducted at the Laboratory of Distributed Generation at Lodz University of Technology. The study was performed for two variants of reference voltage source: the battery storage and microturbine respectively.

  12. High Voltage Piezoelectric System for Generating Neutrons

    Science.gov (United States)

    2013-06-01

    10 mm × 1.5 mm -45-degree rotated y-cut lithium niobate slabs. Input electrodes, shown as gray regions on the top and bottom (not visible) surfaces on...the left portion of the bar in Fig. ??, were used to deliver electrical power to the crystal and applied using silver paint with a measured layer ...voltage, stress, and displacement. The crystals for the PTPS were disks of lithium niobate with 5 mm radius and 2 mm thickness, shown in Fig

  13. A New Asymmetrical Current-fed Converter with Voltage Lifting

    Directory of Open Access Journals (Sweden)

    DELSHAD, M.

    2011-05-01

    Full Text Available This paper presents a new zero voltage switching current-fed DC-DC converter with high voltage gain. In this converter all switches (main and auxiliary turn on under zero voltage switching and turn off under almost zero voltage switching due to snubber capacitor. Furthermore, the voltage spike across the main switch due to leakage inductance of forward transformer is absorbed. The flyback transformer which is connected to the output in series causes to high voltage gain and less voltage stress on the power devices. Considering high efficiency and voltage gain of this converter, it is suitable for green generated systems such as fuel cells or photovoltaic systems. The presented experimental results verify the integrity of the proposed converter.

  14. Artificial intelligence techniques for voltage control

    Energy Technology Data Exchange (ETDEWEB)

    Ekwue, A.; Cheng, D.T.Y.; Macqueen, J.F.

    1997-12-31

    In electric power systems, the advantages of reactive power dispatching or optimisation include improved utilisation of reactive power sources and hence reduction in reactive power flows and real losses of the system; unloading of the system and equipment as a result of reactive flow reduction; the power factors of generation are improved and system security is enhanced; reduced voltage gradients and somewhat higher voltages which result across the system from improved operation; deferred capital investment is new reactive power sources as a result of improved utilisation of existing equipment; and for the National Grid Company plc (NGC), the main advantage is reduced out-of-merit operation. The problem of reactive power control has been studied and widely reported in the literature. Non-linear programming methods as well as linear programming techniques for constraint dispatch have been described. Static optimisation of reactive power sources by the use of sensitivity analysis was described by Kishore and Hill. Long range optimum var planning has been considered and the optimum amount and location of network reactive compensation so as to maintain the system voltage within the desired limits, while operating under normal and various insecurity states, have also been studied using several methods. The objective of this chapter is therefore to review conventional methods as well as AI techniques for reactive power control. (Author)

  15. Soft computing techniques in voltage security analysis

    CERN Document Server

    Chakraborty, Kabir

    2015-01-01

    This book focuses on soft computing techniques for enhancing voltage security in electrical power networks. Artificial neural networks (ANNs) have been chosen as a soft computing tool, since such networks are eminently suitable for the study of voltage security. The different architectures of the ANNs used in this book are selected on the basis of intelligent criteria rather than by a “brute force” method of trial and error. The fundamental aim of this book is to present a comprehensive treatise on power system security and the simulation of power system security. The core concepts are substantiated by suitable illustrations and computer methods. The book describes analytical aspects of operation and characteristics of power systems from the viewpoint of voltage security. The text is self-contained and thorough. It is intended for senior undergraduate students and postgraduate students in electrical engineering. Practicing engineers, Electrical Control Center (ECC) operators and researchers will also...

  16. Online fuzzy voltage collapse risk quantification

    Energy Technology Data Exchange (ETDEWEB)

    Berizzi, A.; Bovo, C.; Delfanti, M.; Merlo, M. [Politecnico di Milano, 20133 Milano (Italy); Cirio, D. [CESI Ricerca (Italy); Pozzi, M. [CESI (Italy)

    2009-05-15

    Many voltage stability indicators have been proposed in the past for the voltage collapse assessment. Almost all of them are determined through quite complex analytical tools; therefore, it is difficult for system operators to give them a physical meaning. In order to perform a simple and reliable evaluation of the security margins, it is necessary to make a synthesis of the information given by the various indices. The present work proposes an Artificial Intelligence-based tool for the evaluation of the voltage security. In particular, a Fuzzy Inference Engine is developed and optimized by two different approaches (Neural Networks and Genetic Algorithms). Starting from the state estimation, a given set of mathematical indices is computed to represent a snapshot of the current electric system operating point. The numerical values are then translated into a set of symbolic and linguistic quantities that are manipulated through a set of logical connectives and Inference Methods provided by the mathematical logic. As a result, the Fuzzy Logic gives a MW measure of the distance from the collapse limit, a metric usually appreciated by system operators. The Fuzzy System has been built and optimized by using, as a test system, a detailed model of the EHV Italian transmission network connected to an equivalent of the UCTE network (about 1700 buses). (author)

  17. Quantum fluctuations of voltage in superconducting nanowires

    Science.gov (United States)

    Semenov, Andrew G.; Zaikin, Andrei D.

    2017-07-01

    At low temperatures non-equilibrium voltage fluctuations can be generated in current-biased superconducting nanowires due to proliferation of quantum phase slips (QPS) or, equivalently, due to quantum tunneling of magnetic flux quanta across the wire. In this paper we review and further extend recent theoretical results related to this phenomenon. Employing the phase-charge duality arguments combined with Keldysh path integral technique we analyze such fluctuations within the two-point and four-point measurement schemes demonstrating that voltage noise detected in such nanowires in general depends on the particular measurement setup. In the low frequency limit we evaluate all cumulants of the voltage operator which turn out to obey Poisson statistics and exhibit a power law dependence on the external bias. We also specifically address a non-trivial frequency dependence of quantum shot noise power spectrum SΩ for both longer and shorter superconducting nanowires. In particular, we demonstrate that SΩ decreases with increasing frequency Ω and vanishes beyond a threshold value of Ω at T → 0. Furthermore, we predict that SΩ may depend non-monotonously on temperature due to quantum coherent nature of QPS noise. The results of our theoretical analysis can be directly tested in future experiments with superconducting nanowires.

  18. DNA-Encoded Dynamic Combinatorial Chemical Libraries.

    Science.gov (United States)

    Reddavide, Francesco V; Lin, Weilin; Lehnert, Sarah; Zhang, Yixin

    2015-06-26

    Dynamic combinatorial chemistry (DCC) explores the thermodynamic equilibrium of reversible reactions. Its application in the discovery of protein binders is largely limited by difficulties in the analysis of complex reaction mixtures. DNA-encoded chemical library (DECL) technology allows the selection of binders from a mixture of up to billions of different compounds; however, experimental results often show low a signal-to-noise ratio and poor correlation between enrichment factor and binding affinity. Herein we describe the design and application of DNA-encoded dynamic combinatorial chemical libraries (EDCCLs). Our experiments have shown that the EDCCL approach can be used not only to convert monovalent binders into high-affinity bivalent binders, but also to cause remarkably enhanced enrichment of potent bivalent binders by driving their in situ synthesis. We also demonstrate the application of EDCCLs in DNA-templated chemical reactions. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Nucleic acid compositions and the encoding proteins

    Science.gov (United States)

    Preston, III, James F.; Chow, Virginia; Nong, Guang; Rice, John D.; St. John, Franz J.

    2014-09-02

    The subject invention provides at least one nucleic acid sequence encoding an aldouronate-utilization regulon isolated from Paenibacillus sp. strain JDR-2, a bacterium which efficiently utilizes xylan and metabolizes aldouronates (methylglucuronoxylosaccharides). The subject invention also provides a means for providing a coordinately regulated process in which xylan depolymerization and product assimilation are coupled in Paenibacillus sp. strain JDR-2 to provide a favorable system for the conversion of lignocellulosic biomass to biobased products. Additionally, the nucleic acid sequences encoding the aldouronate-utilization regulon can be used to transform other bacteria to form organisms capable of producing a desired product (e.g., ethanol, 1-butanol, acetoin, 2,3-butanediol, 1,3-propanediol, succinate, lactate, acetate, malate or alanine) from lignocellulosic biomass.

  20. Parameter Estimation of Turbo Code Encoder

    Directory of Open Access Journals (Sweden)

    Mehdi Teimouri

    2014-01-01

    Full Text Available The problem of reconstruction of a channel code consists of finding out its design parameters solely based on its output. This paper investigates the problem of reconstruction of parallel turbo codes. Reconstruction of a turbo code has been addressed in the literature assuming that some of the parameters of the turbo encoder, such as the number of input and output bits of the constituent encoders and puncturing pattern, are known. However in practical noncooperative situations, these parameters are unknown and should be estimated before applying reconstruction process. Considering such practical situations, this paper proposes a novel method to estimate the above-mentioned code parameters. The proposed algorithm increases the efficiency of the reconstruction process significantly by judiciously reducing the size of search space based on an analysis of the observed channel code output. Moreover, simulation results show that the proposed algorithm is highly robust against channel errors when it is fed with noisy observations.