WorldWideScience

Sample records for enclosure multi-function waste

  1. Position paper: Live load design criteria for Project W-236A Multi-Function Waste Tank Facility

    International Nuclear Information System (INIS)

    Giller, R.A.

    1995-01-01

    The purpose of this paper is to discuss the live loads applied to the underground storage tanks of the Multi Function Waste Tank Facility, and to provide the basis for Project W-236A live load criteria. Project 236A provides encompasses building a Weather Enclosure over the two underground storage tanks at the 200-West area. According to the Material Handling Study, the Groves AT 1100 crane used within the Weather Enclosure will have a gross vehicle weight of 66.5 tons. Therefore, a 100-ton concentrated live load is being used for the planning of the construction of the Weather Enclosure

  2. Material selection for Multi-Function Waste Tank Facility tanks

    International Nuclear Information System (INIS)

    Carlos, W.C.

    1994-01-01

    This report briefly summarizes the history of the materials selection for the US Department of Energy's high-level waste carbon steel storage tanks. It also provide an evaluation of the materials for the construction of new tanks at the Multi-Function Waste Tank Facility. The evaluation included a materials matrix that summarized the critical design, fabrication, construction, and corrosion resistance requirements; assessed each requirement; and cataloged the advantages and disadvantages of each material. This evaluation is based on the mission of the Multi-Function Waste Tank Facility. On the basis of the compositions of the wastes stored in Hanford waste tanks, it is recommended that tanks for the Multi-Function Waste Tank Facility be constructed of normalized ASME SA 516, Grade 70, carbon steel

  3. Recommendations for erosion-corrosion allowance for Multi-Function Waste Tank Facility tanks

    International Nuclear Information System (INIS)

    Carlos, W.C.; Brehm, W.F.; Larrick, A.P.; Divine, J.R.

    1994-10-01

    The Multi-Function Waste Tank Facility carbon steel tanks will contain mixer pumps that circulate the waste. On the basis of flow characteristics of the system and data from the literature, an erosion allowance of 0.075 mm/y (3 mil/year) was recommended for the tank bottoms, in addition to the 0.025 mm/y (1 mil/year) general corrosion allowance

  4. Management plan -- Multi-Function Waste Tank Facility. Revision 1

    International Nuclear Information System (INIS)

    Fritz, R.L.

    1995-01-01

    This Westinghouse Hanford Company (WHC) Multi-Function Waste Tank Facility (MWTF) Management Plan provides guidance for execution WHC MWTF Project activities related to design, procurement, construction, testing, and turnover. This Management Plan provides a discussion of organizational responsibilities, work planning, project management systems, quality assurance (QA), regulatory compliance, personnel qualifications and training, and testing and evaluations. Classified by the US Department of Energy (DOE) as a major systems acquisition (MSA), the MWTF mission is to provide a safe, cost-effective, and environmentally sound method for interim storage of Hanford Site high-level wastes. This Management Plan provides policy guidance and direction to the Project Office for execution of the project activities

  5. Management plan -- Multi-Function Waste Tank Facility. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, R.L.

    1995-01-11

    This Westinghouse Hanford Company (WHC) Multi-Function Waste Tank Facility (MWTF) Management Plan provides guidance for execution WHC MWTF Project activities related to design, procurement, construction, testing, and turnover. This Management Plan provides a discussion of organizational responsibilities, work planning, project management systems, quality assurance (QA), regulatory compliance, personnel qualifications and training, and testing and evaluations. Classified by the US Department of Energy (DOE) as a major systems acquisition (MSA), the MWTF mission is to provide a safe, cost-effective, and environmentally sound method for interim storage of Hanford Site high-level wastes. This Management Plan provides policy guidance and direction to the Project Office for execution of the project activities.

  6. Structural design and analysis of the multi-function waste tanks

    International Nuclear Information System (INIS)

    Farnworth, S.K.; Stine, M.D.; Miller, L.K.

    1993-10-01

    This paper describes structural design and analysis procedures to be used for the Multi-function Waste Tank Facility underground waste storage tanks proposed for the Hanford Site. The Multi-function Waste Tank Facility will consist of four one-million-gallon nominal capacity, double-shell, underground waste storage tanks and will include the associated process and control systems and aboveground structures. The tanks will consist of an inner primary steel tank and an outer secondary reinforced-concrete steel-lined tank. The primary tank head will be structurally attached to the concrete dome. A supporting layer of material will be placed between the bottom of the primary steel tank and the bottom of the steel liner on the secondary tank. The tank analysis is undertaken jointly by a team of engineers and analysts representing Kaiser Engineers Hanford, the site architect/engineer, and Westinghouse Hanford Company, the site management and operating contractor. This analysis is planned in several phases. Heat transfer solutions will address the anticipated mixing pump and cyclic fill/drain environment to provide steel and concrete temperature distributions. With this information, an in situ static analysis of the reinforced-concrete secondary tank will be carried out over the structure design life and will give material states and deformations along with strength and stability checks. Seismic analysis, accounting for soil-structure interaction and liquid loads, will be conducted with the most conservative material state, and the in situ deformations will be incorporated. Finally, penetrations and other components will be analyzed

  7. Structural design and analysis of the multi-function waste tanks

    International Nuclear Information System (INIS)

    Farnworth, S.K.; Stine, M.D.; Miller, L.K.

    1993-01-01

    This paper describes structural design and analysis procedures to be used for the Multi-function Waste Tank Facility underground waste storage tanks proposed for the Hanford Site. The Multi-function Waste Tank Facility will consist of four one-million-gallon nominal capacity, double-shell, underground waste storage tanks and will include the associated process and control systems and aboveground structures. The tanks will consist of an inner primary steel tank and an outer secondary reinforced-concrete steel-linked tank. The primary tank head will be structurally attached to the concrete dome. A supporting layer of material will be placed between the bottom of the primary steel tank and the bottom of the steel linear on the secondary tank. The tank analysis is undertaken jointly by a team of engineers and analysts representing Kaiser Engineers Hanford, the site architect/engineer, and Westinghouse Hanford Company, the site management and operating contractor. This analysis is planned in several phases. Heat transfer solutions will address the anticipated mixing pump and cyclic fill/drain environment to provide steel and concrete temperature distributions. With this information, an in situ static analysis of the reinforced-concrete secondary tank will be carried out over the structure design life and will give material states and deformations along with strength and stability checks. Seismic analysis, accounting for soil-structure interaction and liquid loads, will be conducted with the most conservative material state, and the in situ deformations will be incorporated. Finally, penetrations and other components will be analyzed

  8. VLT enclosures: design and construction

    Science.gov (United States)

    Schneermann, Michael W.; Marchiori, Gianpietro; Dimichino, Francesco

    1997-03-01

    The VLT enclosures main functions are to protect the telescopes during operational as well as non-operational phases from any adverse weather conditions and to provide optimal conditions for observation. An adequate design of a ventilation and wind protection system is important for the performance of the enclosures with respect to the minimization of the corresponding seeing effects. The VLT enclosures are equipped with ventilation doors on the azimuth platform level, with louvers on the rotating part and with a windscreen at the observing slit. Extensive qualification tests of the louvers and windscreen mechanical assemblies have been performed during the enclosures development phase. This paper gives an overview over the general layout of the enclosures and the major subsystems, summarizes the main functional specifications and gives the main results and conclusions of the functional performance tests. Presently the first enclosure erection is nearing its completion and pre- commissioning of all systems will commence. The status of the site erection of the enclosures is presented and the planning for the next phases of the erection is presented.

  9. Preconceptual design for the electrostatic enclosure

    International Nuclear Information System (INIS)

    Meyer, L.C.

    1992-09-01

    This report presents a preconceptual design (design criteria and assumptions) for electrostatic enclosures to be used during buried transuranic waste recovery operations. These electrostatic enclosures (along with the application of dust control products) will provide an in-depth contamination control strategy. As part of this preconceptual design, options for electrostatic curtain design are given including both hardwall and fabric enclosures. Ventilation systems, doors, air locks, electrostatic curtains, and supporting systems also are discussed. In addition to the conceptual design, engineering scale tests are proposed to be run at the Test Reactor Area. The planned engineering scale tests will give final material specifications for full-scale retrieval demonstrations

  10. Integrated thermal control and system assessment in plug-chip spray cooling enclosure

    International Nuclear Information System (INIS)

    Zhang, Wei-Wei; Cheng, Wen-Long; Shao, Shi-Dong; Jiang, Li-Jia; Hong, Da-Liang

    2016-01-01

    Highlights: • A novel multi-heat source plug-chip spray cooling enclosure was designed. • Enhanced surfaces with different geometric were analyzed in integrated enclosure. • Overall thermal control with adjustable parameters in enclosure was studied. • Temperature disequilibrium of multi-heat source in enclosure was tested. • A comprehensive assessment system used to evaluate the practicality was proposed. - Abstract: Practical and integrated spray cooling system is urgently needed for the cooling of high-performance electronic chips due to the growth requirements of thermal management in workstation. The integration of multi heat sources and the management of integral system are particularly lacking. In order to fill the vacancies in the study of plug-chip spray cooling, an integrated cooling enclosure was designed in this paper. Multi heat sources were placed in sealed space and the heat was removed by spray. The printed circuit board plug-ins and radio frequency resistors were used as analog motherboards and chips, respectively. The enhanced surfaces with four different geometries and the plain surface were studied under the conditions of different inclination angles. The results were compared and the maximum critical heat flux (CHF) was obtained. Moreover, with the intention of the overall management of multi-heat source in integrated enclosure, the effect of the flow rate and the temperature disequilibrium, and the pulse heating in the process of transient cooling were also analyzed. In addition, a comprehensive assessment system, used to evaluate the practicality of spray cooling experimental devices, was proposed and the performance of enclosure was evaluated.

  11. The effects of lead on multi-function waste tank facility carbon steels

    International Nuclear Information System (INIS)

    Carlos, W.C.

    1994-01-01

    Work previously reported in the literature suggests the presence of lead in boiling caustic can crack carbon steel. Further, most of the single-shell tanks presumed to be leakers contain lead from past fuel reprocessing work. While the Multi-Function Waste Tank Facility will be operating at temperatures far below those in which cracking occurred and the waste will have other components including inhibitors, there is a possibility that the lead concentration in some of the waste will exceed that found earlier to cause cracking. Consequently it is recommended that tests be performed on simulated wastes to better define the solubility and to determine whether cracking under proposed operating conditions is a serious concern. However, the experimental evaluation does not need to be performed immediately. The waste believed to have the largest lead concentration, B-Farm, is not shown in the current processing schedule which goes to the year 2011. The wastes scheduled for processing have less than about one-tenth of one percent of the lead concentration found in B-Farm

  12. A Cask Processing Enclosure for the TRU Waste Processing Center - 13408

    Energy Technology Data Exchange (ETDEWEB)

    Newman, John T.; Mendez, Nicholas [IP Systems, Inc., 2685 Industrial Lane, Broomfield, Colorado 80020 (United States)

    2013-07-01

    This paper will discuss the key elements considered in the design, construction, and use of an enclosure system built for the TRU Waste Processing Center (TWPC). The TWPC system is used for the repackaging and volume reduction of items contaminated with radioactive material, hazardous waste and mixed waste. The modular structural steel frame and stainless steel skin was designed for rapid field erection by the use of interchangeable self-framing panel sections to allow assembly of a sectioned containment building and for ease of field mobility. The structure was installed on a concrete floor inside of an outer containment building. The major sections included an Outer Cask Airlock, Inner Cask Airlock, Cask Process Area, and Personnel Airlocks. Casks in overpacks containing transuranic waste are brought in via an inter-site transporter. The overpack lid is removed and the cask/overpack is transferred into the Outer Cask Airlock. A contamination cover is installed on the overpack body and the Outer Cask Airlock is closed. The cask/overpack is transferred into the Inner Cask Airlock on a cask bogie and the Inner Cask Airlock is closed. The cask lid is removed and the cask is transferred into the Cask Process Area where it is placed on a cask tilting station. Once the Cask Processing Area is closed, the cask tilt station is activated and wastes are removed, size reduced, then sorted and re-packaged into drums and standard waste boxes through bag ports. The modular system was designed and built as a 'Fast Track' project at IP Systems in Broomfield Colorado and then installed and is currently in use at the DOE TWPC located near Oak Ridge, Tennessee. (authors)

  13. Multi-Function Waste Tank Facility Corrosion Test Report (Phase 1)

    International Nuclear Information System (INIS)

    Carlos, W. C.; Fritz, R. L.

    1993-01-01

    This report documents the results of the corrosion tests that were performed to aid in the selection of the construction materials for multi-function waste tanks to be built in the U.S. Department of Energy Hanford Site. Two alloys were tested: 304L and Alloy 20 austenitic stainless steel. The test media were aqueous solutions formulated to represent the extreme of the chemical compositions of waste to be stored in the tanks. The results summerized by alloy are as follows: For 304L the tests showed no stress-corrosion cracking in any of the nine test solutions. The tests showed pitting in on of the solutions. There were no indications of any weld heat-tint corrosion, nor any sign of preferential corrosion in the welded areas. For Alloy 20 the tests showed no general, pitting, or stress-corrosion cracking. One crevice corrosion coupon cracked at the web between a hole and the edge of the coupon in one of the solutions. Mechanical tests showed some possible crack extension in the same solution. Because of the failure of both alloys to meet test acceptance criteria, the tank waste chemistry will have to be restricted or an alternative alloy tested

  14. Test plan for engineering scale electrostatic enclosure demonstration

    International Nuclear Information System (INIS)

    Meyer, L.C.

    1993-02-01

    This test plan describes experimental details of an engineering-scale electrostatic enclosure demonstration to be performed at the Idaho National Engineering Laboratory in fiscal year (FY)-93. This demonstration will investigate, in the engineering scale, the feasibility of using electrostatic enclosures and devices to control the spread of contaminants during transuranic waste handling operations. Test objectives, detailed experimental procedures, and data quality objectives necessary to perform the FY-93 experiments are included in this plan

  15. Hazard and operability study of the multi-function Waste Tank Facility. Revision 1

    International Nuclear Information System (INIS)

    Hughes, M.E.

    1995-01-01

    The Multi-Function Waste Tank Facility (MWTF) East site will be constructed on the west side of the 200E area and the MWTF West site will be constructed in the SW quadrant of the 200W site in the Hanford Area. This is a description of facility hazards that site personnel or the general public could potentially be exposed to during operation. A list of preliminary Design Basis Accidents was developed

  16. Multi-Function Waste Tank Facility thermal hydraulic analysis for Title II design

    International Nuclear Information System (INIS)

    Cramer, E.R.

    1994-01-01

    The purpose of this work was to provide the thermal hydraulic analysis for the Multi-Function Waste Tank Facility (MWTF) Title II design. Temperature distributions throughout the tank structure were calculated for subsequent use in the structural analysis and in the safety evaluation. Calculated temperatures of critical areas were compared to design allowables. Expected operating parameters were calculated for use in the ventilation system design and in the environmental impact documentation. The design requirements were obtained from the MWTF Functional Design Criteria (FDC). The most restrictive temperature limit given in the FDC is the 200 limit for the haunch and dome steel and concrete. The temperature limit for the rest of the primary and secondary tanks and concrete base mat and supporting pad is 250 F. Also, the waste should not be allowed to boil. The tank geometry was taken from ICF Kaiser Engineers Hanford drawing ES-W236A-Z1, Revision 1, included here in Appendix B. Heat removal rates by evaporation from the waste surface were obtained from experimental data. It is concluded that the MWTF tank cooling system will meet the design temperature limits for the design heat load of 700,000 Btu/h, even if cooling flow is lost to the annulus region, and temperatures change very slowly during transients due to the high heat capacity of the tank structure and the waste. Accordingly, transients will not be a significant operational problem from the viewpoint of meeting the specified temperature limits

  17. Fire Research Enclosure

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Simulates submarine fires, enclosed aircraft fires, and fires in enclosures at shore facilities .DESCRIPTION: FIRE I is a pressurizable, 324 cu m(11,400 cu...

  18. Radioactive waste material melter apparatus

    Science.gov (United States)

    Newman, D.F.; Ross, W.A.

    1990-04-24

    An apparatus for preparing metallic radioactive waste material for storage is disclosed. The radioactive waste material is placed in a radiation shielded enclosure. The waste material is then melted with a plasma torch and cast into a plurality of successive horizontal layers in a mold to form a radioactive ingot in the shape of a spent nuclear fuel rod storage canister. The apparatus comprises a radiation shielded enclosure having an opening adapted for receiving a conventional transfer cask within which radioactive waste material is transferred to the apparatus. A plasma torch is mounted within the enclosure. A mold is also received within the enclosure for receiving the melted waste material and cooling it to form an ingot. The enclosure is preferably constructed in at least two parts to enable easy transport of the apparatus from one nuclear site to another. 8 figs.

  19. Radioactive waste material melter apparatus

    International Nuclear Information System (INIS)

    Newman, D.F.; Ross, W.A.

    1990-01-01

    An apparatus for preparing metallic radioactive waste material for storage is disclosed. The radioactive waste material is placed in a radiation shielded enclosure. The waste material is then melted with a plasma torch and cast into a plurality of successive horizontal layers in a mold to form a radioactive ingot in the shape of a spent nuclear fuel rod storage canister. The apparatus comprises a radiation shielded enclosure having an opening adapted for receiving a conventional transfer cask within which radioactive waste material is transferred to the apparatus. A plasma torch is mounted within the enclosure. A mold is also received within the enclosure for receiving the melted waste material and cooling it to form an ingot. The enclosure is preferably constructed in at least two parts to enable easy transport of the apparatus from one nuclear site to another. 8 figs

  20. Material containment enclosure

    International Nuclear Information System (INIS)

    Carlson, D.O.

    1993-01-01

    An isolation enclosure and a group of isolation enclosures are described which are useful when a relatively large containment area is required. The enclosure is in the form of a ring having a section removed so that a technician may enter the center area of the ring. In a preferred embodiment, an access zone is located in the transparent wall of the enclosure and extends around the inner perimeter of the ring so that a technician can insert his hands into the enclosure to reach any point within. The inventive enclosures provide more containment area per unit area of floor space than conventional material isolation enclosures. 3 figures

  1. Natural convection in asymmetric triangular enclosures heated from below

    Science.gov (United States)

    Kamiyo, O. M.; Angeli, D.; Barozzi, G. S.; Collins, M. W.

    2014-11-01

    Triangular enclosures are typical configurations of attic spaces found in residential as well as industrial pitched-roof buildings. Natural convection in triangular rooftops has received considerable attention over the years, mainly on right-angled and isosceles enclosures. In this paper, a finite volume CFD package is employed to study the laminar air flow and temperature distribution in asymmetric rooftop-shaped triangular enclosures when heated isothermally from the base wall, for aspect ratios (AR) 0.2 <= AR <= 1.0, and Rayleigh number (Ra) values 8 × 105 <= Ra <= 5 × 107. The effects of Rayleigh number and pitch angle on the flow structure and temperature distributions within the enclosure are analysed. Results indicate that, at low pitch angle, the heat transfer between the cold inclined and the hot base walls is very high, resulting in a multi-cellular flow structure. As the pitch angle increases, however, the number of cells reduces, and the total heat transfer rate progressively reduces, even if the Rayleigh number, being based on the enclosure height, rapidly increases. Physical reasons for the above effect are inspected.

  2. Captive chimpanzee (Pan troglodytes) behavior as a function of space per animal and enclosure type.

    Science.gov (United States)

    Neal Webb, Sarah J; Hau, Jann; Schapiro, Steven J

    2018-03-01

    Space per animal, or animal density, and enclosure type are important elements of functionally appropriate captive environments (FACEs) for chimpanzees. The National Institutes of Health (NIH) recommends that captive chimpanzees be maintained in areas of >250 ft 2 /animal. Several studies have investigated chimpanzee behavior in relation to space per animal, but only two studies have examined these variables while attempting to hold environmental complexity constant. Both have found few, if any, significant differences in behavior associated with increased space per animal. The NIH does not provide recommendations pertaining to enclosure type. Although Primadomes™ and corrals are considered acceptable FACE housing, no studies have investigated chimpanzee behavior in relation to these two common types of enclosures. We examined the NIH space per animal recommendation, and the effects of enclosure type, while maintaining similar levels of environmental complexity. We used focal animal observations to record the behavior of 22 chimpanzees in three social groups following within-facility housing transfers. Chimpanzees that were moved from an area with space below the NIH recommendation to the same type of enclosure with space above the recommendation (dome to double dome) exhibited significantly more locomotion and behavioral diversity post-transfer. Chimpanzees that were moved from an area with space below the recommendation to a different type of enclosure with space above the recommendation (dome to corral) exhibited significant increases in foraging and behavioral diversity, and a decrease in rough scratching. Lastly, chimpanzees that were moved from an area above the recommendation to a different enclosure type with space equal to the recommendation (corral to double dome) exhibited an increase in behavioral diversity. These results add to the body of literature that addresses the concept of specific minimum space requirements per chimpanzee, and highlight the

  3. Natural convection in asymmetric triangular enclosures heated from below

    International Nuclear Information System (INIS)

    Kamiyo, O M; Angeli, D; Enzo Ferrari, Universita di Modena e Reggio Emilia, via Vignolese 905, I-41125 Modena (Italy))" data-affiliation=" (DIEF – Dipartimento di Ingegneria Enzo Ferrari, Universita di Modena e Reggio Emilia, via Vignolese 905, I-41125 Modena (Italy))" >Barozzi, G S; Collins, M W

    2014-01-01

    Triangular enclosures are typical configurations of attic spaces found in residential as well as industrial pitched-roof buildings. Natural convection in triangular rooftops has received considerable attention over the years, mainly on right-angled and isosceles enclosures. In this paper, a finite volume CFD package is employed to study the laminar air flow and temperature distribution in asymmetric rooftop-shaped triangular enclosures when heated isothermally from the base wall, for aspect ratios (AR) 0.2 ≤ AR ≤ 1.0, and Rayleigh number (Ra) values 8 × 10 5 ≤ Ra ≤ 5 × 10 7 . The effects of Rayleigh number and pitch angle on the flow structure and temperature distributions within the enclosure are analysed. Results indicate that, at low pitch angle, the heat transfer between the cold inclined and the hot base walls is very high, resulting in a multi-cellular flow structure. As the pitch angle increases, however, the number of cells reduces, and the total heat transfer rate progressively reduces, even if the Rayleigh number, being based on the enclosure height, rapidly increases. Physical reasons for the above effect are inspected

  4. Interaction Between Flow Elements in Large Enclosures

    DEFF Research Database (Denmark)

    Heiselberg, Per

    and if this influences the overall air flow pattern in the enclosure. The main emphasis has been put on the pathways of chilled free air jets and whether the convective flows from both distributed and concentrated heat sources affect the pathway of the jet and the air flow pattern in the enclosure as a function......In this paper experiments in a scale model are used as a first attempt to investigate how different flow elements such as supply air jets, thermal plumes and free convection flows interact with each other in a large enclosure, if the path of each individual flow element changes...... of the location of the heat source and as a function of the heat supplied by the source....

  5. Plume and Dose Modeling Performed to Assess Waste Management Enhancements Associated with Envirocare's Decision to Purchase of an Engineered Rail Rollover Facility Enclosure

    International Nuclear Information System (INIS)

    Rogers, T.; Clayman, B.

    2003-01-01

    This paper describes the modeling performed on a proposed enclosure for the existing railcar rollover facility located in Clive, Utah at a radioactive waste disposal site owned and operated by Envirocare of Utah, Inc. (Envirocare). The dose and plume modeling information was used as a tool to justify the decision to make the capital purchase and realize the modeled performance enhancements

  6. Effects of hydrogen on carbon steels at the Multi-Function Waste Tank Facility

    International Nuclear Information System (INIS)

    Carlos, W.C.

    1995-01-01

    Concern has been expressed that hydrogen produced by corrosion, radiolysis, and decomposition of the waste could cause embrittlement of the carbon steel waste tanks at Hanford. The concern centers on the supposition that the hydrogen evolved in many of the existing tanks might penetrate the steel wall of the tank and cause embrittlement that might lead to catastrophic failure. This document reviews literature on the effects of hydrogen on the carbon steel proposed for use in the Multi-Function Waste Tank Facility for the time periods before and during construction as well as for the operational life of the tanks. The document draws several conclusions about these effects. Molecular hydrogen is not a concern because it is not capable of entering the steel tank wall. Nascent hydrogen produced by corrosion reactions will not embrittle the steel because the mild steel used in tank construction is not hard enough to be susceptible to hydrogen stress cracking and the corrosion product hydrogen is not produced at a rate sufficient to cause either loss in tensile ductility or blistering. If the steel intended for use in the tanks is produced to current technology, fabricated in accordance with good construction practice, postweld heat treated, and operated within the operating limits defined, hydrogen will not adversely affect the carbon steel tanks during their 50-year design life. 26 refs

  7. Activation analysis and waste management for blanket materials of multi-functional experimental fusion–fission hybrid reactor (FDS-MFX)

    International Nuclear Information System (INIS)

    Jiang, Jieqiong; Yuan, Baoxin; Zou, Jun; Wu, Yican

    2014-01-01

    The preliminary studies of the activation analysis and waste management for blanket materials of the multi-functional experimental fusion–fission hybrid reactor, i.e. Multi-Functional eXperimental Fusion Driven Subcritical system named FDS-MFX, were performed. The neutron flux of the FDS-MFX blanket was calculated using VisualBUS code and Hybrid Evaluated Nuclear Data Library (HENDL) developed by FDS Team. Based on these calculated neutron fluxes, the activation properties of blanket materials were analyzed by the induced radioactivity, the decay heat and the contact dose rate for different regions of the FDS-MFX blanket. The safety and environment assessment of fusion power (SEAFP) strategy, which was developed in Europe, was applied to FDS-MFX blanket for the management of activated materials. Accordingly, the classification and management strategy of activated materials after different cooling time were proposed for FDS-MFX blanket

  8. VIRUS instrument enclosures

    Science.gov (United States)

    Prochaska, T.; Allen, R.; Mondrik, N.; Rheault, J. P.; Sauseda, M.; Boster, E.; James, M.; Rodriguez-Patino, M.; Torres, G.; Ham, J.; Cook, E.; Baker, D.; DePoy, Darren L.; Marshall, Jennifer L.; Hill, G. J.; Perry, D.; Savage, R. D.; Good, J. M.; Vattiat, Brian L.

    2014-08-01

    The Visible Integral-Field Replicable Unit Spectrograph (VIRUS) instrument will be installed at the Hobby-Eberly Telescope† in the near future. The instrument will be housed in two enclosures that are mounted adjacent to the telescope, via the VIRUS Support Structure (VSS). We have designed the enclosures to support and protect the instrument, to enable servicing of the instrument, and to cool the instrument appropriately while not adversely affecting the dome environment. The system uses simple HVAC air handling techniques in conjunction with thermoelectric and standard glycol heat exchangers to provide efficient heat removal. The enclosures also provide power and data transfer to and from each VIRUS unit, liquid nitrogen cooling to the detectors, and environmental monitoring of the instrument and dome environments. In this paper, we describe the design and fabrication of the VIRUS enclosures and their subsystems.

  9. Rigorous high-precision enclosures of fixed points and their invariant manifolds

    Science.gov (United States)

    Wittig, Alexander N.

    The well established concept of Taylor Models is introduced, which offer highly accurate C0 enclosures of functional dependencies, combining high-order polynomial approximation of functions and rigorous estimates of the truncation error, performed using verified arithmetic. The focus of this work is on the application of Taylor Models in algorithms for strongly non-linear dynamical systems. A method is proposed to extend the existing implementation of Taylor Models in COSY INFINITY from double precision coefficients to arbitrary precision coefficients. Great care is taken to maintain the highest efficiency possible by adaptively adjusting the precision of higher order coefficients in the polynomial expansion. High precision operations are based on clever combinations of elementary floating point operations yielding exact values for round-off errors. An experimental high precision interval data type is developed and implemented. Algorithms for the verified computation of intrinsic functions based on the High Precision Interval datatype are developed and described in detail. The application of these operations in the implementation of High Precision Taylor Models is discussed. An application of Taylor Model methods to the verification of fixed points is presented by verifying the existence of a period 15 fixed point in a near standard Henon map. Verification is performed using different verified methods such as double precision Taylor Models, High Precision intervals and High Precision Taylor Models. Results and performance of each method are compared. An automated rigorous fixed point finder is implemented, allowing the fully automated search for all fixed points of a function within a given domain. It returns a list of verified enclosures of each fixed point, optionally verifying uniqueness within these enclosures. An application of the fixed point finder to the rigorous analysis of beam transfer maps in accelerator physics is presented. Previous work done by

  10. Detection of free liquid in containers of solidified radioactive waste

    Science.gov (United States)

    Greenhalgh, Wilbur O.

    1985-01-01

    A method of nondestructively detecting the presence of free liquid within a sealed enclosure containing solidified waste by measuring the levels of waste at two diametrically opposite locations while slowly tilting the enclosure toward one of said locations. When the measured level remains constant at the other location, the measured level at said one location is noted and any measured difference of levels indicates the presence of liquid on the surface of the solidified waste. The absence of liquid in the enclosure is verified when the measured levels at both locations are equal.

  11. Detection of free liquid in containers of solidified radioactive waste

    Science.gov (United States)

    Greenhalgh, W.O.

    Nondestructive detection of the presence of free liquid within a sealed enclosure containing solidified waste is accomplished by measuring the levels of waste at two diametrically opposite locations while slowly tilting the enclosure toward one of said locations. When the measured level remains constant at the other location, the measured level at said one location is noted and any measured difference of levels indicates the presence of liquid on the surface of the solifified waste. The absence of liquid in the enclosure is verified when the measured levels at both locations are equal.

  12. Design review plan for Multi-Function Waste Tank Facility (Project W-236A)

    International Nuclear Information System (INIS)

    Renfro, G.G.

    1994-01-01

    This plan describes how the Multi-Function Waste Tank Facility (MWTF) Project conducts reviews of design media; describes actions required by Project participants; and provides the methodology to ensure that the design is complete, meets the technical baseline of the Project, is operable and maintainable, and is constructable. Project W-236A is an integrated project wherein the relationship between the operating contractor and architect-engineer is somewhat different than that of a conventional project. Working together, Westinghouse Hanford Company (WHC) and ICF Karser Hanford (ICF KH) have developed a relationship whereby ICF KH performs extensive design reviews and design verification. WHC actively participates in over-the-shoulder reviews during design development, performs a final review of the completed design, and conducts a formal design review of the Safety Class I, ASME boiler and Pressure Vessel Code items in accordance with WHC-CM-6-1, Standard Engineering Practices

  13. Position paper, need for additional waste storage capacity and recommended path forward for project W-236a, Multi-function Waste Tank Facility

    International Nuclear Information System (INIS)

    Awadalla, N.G.

    1994-01-01

    Project W-236a, Multi-function waste Tank Facility (MWTF), was initiated to increase the safe waste storage capacity for the Tank Waste Remediation System (TWRS) by building two new one million gallon underground storage tanks in the 200 West Area and four tanks in the 200 East Area. Construction of the tanks was scheduled to begin in September 1994 with operations beginning in calendar year (CY) 1998. However, recent reviews have raised several issues regarding the mission, scope, and schedule of the MWTF. The decision to build new tanks must consider several elements, such as: Operational risk and needs -- Operational risk and flexibility must be managed such that any identified risk is reduced as soon as practicable; The amount of waste that will be generated in the future -- Additional needed tank capacity must be made available to support operations and maintain currently planned safety improvement activities; Safety issues -- The retrieval of waste from single-shell tanks (SSTs) and watch list tanks will add to the total amount of waste that must be stored in a double-shell tank (DST); Availability of existing DSTs -- The integrity of the 28 existing DSTs must be continuously managed; and Affect on other projects and programs -- Because MWTF systems have been integrated with other projects, a decision on one project will affect another. In addition the W-236a schedule is logically tied to support retrieval and safety program plans. Based on the above, two new tanks are needed for safe waste storage in the 200 West Area, and they need to be built as soon as practicable. Design should continue for the tanks in the 200 East Area with a decision made by September, on whether to construct them. Construction of the cross-site transfer line should proceed as scheduled. To implement this recommendation several actions need to be implemented

  14. Process and device for material transfer from a contaminated enclosure into a second enclosure without contamination of this last one

    International Nuclear Information System (INIS)

    Glachet, C.; Ponchet, L.

    1992-01-01

    A shipping container containing a transfer vessel is contacted with the contaminated enclosure. The three coupled doors of the enclosure, of the container and of the vessel are removed together and products are transferred from the enclosure to the vessel, without communication of the atmosphere of the container outside the vessel and of the enclosure are in communication. The 3 doors are closed and the container is removed for transport toward a second enclosure. The three doors of this second enclosure and of the container are opened to introduce in the second enclosure the transfer vessel containing the products

  15. Selecting suitable enclosures for digitally printed materials

    International Nuclear Information System (INIS)

    Burge, D; Rima, L

    2010-01-01

    It cannot be assumed that storage enclosures considered safe for traditionally printed images and documents are suitable for modern, digitally printed materials. In this project, a large variety of digital print types were tested using a modified version of the ISO 18916 Imaging materials-Processed imaging materials-Photographic activity test for enclosure materials standard to assess the risk to digital prints by paper enclosures known to be inert or reactive with traditional photographic prints. The types of enclosures tested included buffered and non-buffered cotton papers, and groundwood paper. In addition, qualitative filter paper that had been wetted and dried with either an acidic or basic solution was also tested to determine the effects of enclosure pH on digitally printed materials. It was determined that, in general, digital prints tended to be less reactive with various enclosure types than traditional prints. Digital prints were most sensitive to paper that contained groundwood. The enclosure reactivity test results were then integrated with previous published work on the tendencies of various enclosure types to abrade, ferrotype, or block to digital prints in order to create a comprehensive set of recommendations for digital print storage enclosures.

  16. Multi-Function Waste Tank Facility Quality Assurance Program Plan, Project W-236A. Revision 2

    Energy Technology Data Exchange (ETDEWEB)

    Hall, L.R.

    1995-05-30

    This document describes the Quality Assurance (QA) program for the Multi-Function Waste Tank Facility (MWTF) Project. The purpose of this QA program is to control project activities in such a manner as to achieve the mission of the MWTF Project in a safe and reliable manner. The QA program for the MWTF Project is founded on DOE Order 5700.6C, Quality Assurance, and implemented through the use of ASME NQA-1, Quality Assurance Program Requirements for Nuclear Facilities (ASME 1989 with addenda la-1989, lb-1991 and lc-1992). This document describes the program and planned actions which the Westinghouse Hanford Company (WHC) will implement to demonstrate and ensure that the project meets the requirements of DOE Order 5700.6C through the interpretive guidance of ASME NQA-1.

  17. Multi-Function Waste Tank Facility Quality Assurance Program Plan, Project W-236A. Revision 2

    International Nuclear Information System (INIS)

    Hall, L.R.

    1995-01-01

    This document describes the Quality Assurance (QA) program for the Multi-Function Waste Tank Facility (MWTF) Project. The purpose of this QA program is to control project activities in such a manner as to achieve the mission of the MWTF Project in a safe and reliable manner. The QA program for the MWTF Project is founded on DOE Order 5700.6C, Quality Assurance, and implemented through the use of ASME NQA-1, Quality Assurance Program Requirements for Nuclear Facilities (ASME 1989 with addenda la-1989, lb-1991 and lc-1992). This document describes the program and planned actions which the Westinghouse Hanford Company (WHC) will implement to demonstrate and ensure that the project meets the requirements of DOE Order 5700.6C through the interpretive guidance of ASME NQA-1

  18. Tank waste remediation system multi-year work plan

    International Nuclear Information System (INIS)

    1994-09-01

    The Tank Waste Remediation System (TWRS) Multi-Year Work Plan (MYWP) documents the detailed total Program baseline and was constructed to guide Program execution. The TWRS MYWP is one of two elements that comprise the TWRS Program Management Plan. The TWRS MYWP fulfills the Hanford Site Management System requirement for a Multi-Year Program Plan and a Fiscal-Year Work Plan. The MYWP addresses program vision, mission, objectives, strategy, functions and requirements, risks, decisions, assumptions, constraints, structure, logic, schedule, resource requirements, and waste generation and disposition. Sections 1 through 6, Section 8, and the appendixes provide program-wide information. Section 7 includes a subsection for each of the nine program elements that comprise the TWRS Program. The foundation of any program baseline is base planning data (e.g., defendable product definition, logic, schedules, cost estimates, and bases of estimates). The TWRS Program continues to improve base data. As data improve, so will program element planning, integration between program elements, integration outside of the TWRS Program, and the overall quality of the TWRS MYWP. The MYWP establishes the TWRS baseline objectives to store, treat, and immobilize highly radioactive Hanford waste in an environmentally sound, safe, and cost-effective manner. The TWRS Program will complete the baseline mission in 2040 and will incur costs totalling approximately 40 billion dollars. The summary strategy is to meet the above objectives by using a robust systems engineering effort, placing the highest possible priority on safety and environmental protection; encouraging open-quotes out sourcingclose quotes of the work to the extent practical; and managing significant but limited resources to move toward final disposition of tank wastes, while openly communicating with all interested stakeholders

  19. Tank waste remediation system multi-year work plan

    Energy Technology Data Exchange (ETDEWEB)

    1994-09-01

    The Tank Waste Remediation System (TWRS) Multi-Year Work Plan (MYWP) documents the detailed total Program baseline and was constructed to guide Program execution. The TWRS MYWP is one of two elements that comprise the TWRS Program Management Plan. The TWRS MYWP fulfills the Hanford Site Management System requirement for a Multi-Year Program Plan and a Fiscal-Year Work Plan. The MYWP addresses program vision, mission, objectives, strategy, functions and requirements, risks, decisions, assumptions, constraints, structure, logic, schedule, resource requirements, and waste generation and disposition. Sections 1 through 6, Section 8, and the appendixes provide program-wide information. Section 7 includes a subsection for each of the nine program elements that comprise the TWRS Program. The foundation of any program baseline is base planning data (e.g., defendable product definition, logic, schedules, cost estimates, and bases of estimates). The TWRS Program continues to improve base data. As data improve, so will program element planning, integration between program elements, integration outside of the TWRS Program, and the overall quality of the TWRS MYWP. The MYWP establishes the TWRS baseline objectives to store, treat, and immobilize highly radioactive Hanford waste in an environmentally sound, safe, and cost-effective manner. The TWRS Program will complete the baseline mission in 2040 and will incur costs totalling approximately 40 billion dollars. The summary strategy is to meet the above objectives by using a robust systems engineering effort, placing the highest possible priority on safety and environmental protection; encouraging {open_quotes}out sourcing{close_quotes} of the work to the extent practical; and managing significant but limited resources to move toward final disposition of tank wastes, while openly communicating with all interested stakeholders.

  20. Measurements of density profile evolution during the stably-stratified filling of an open enclosure

    International Nuclear Information System (INIS)

    Tarawneh, Constantine M.; Homan, K.O.

    2008-01-01

    The stably-stratified filling of an open enclosure produces an interfacial gradient layer which is transported through the enclosure with the bulk flow. The evolution of this interfacial layer is strongly time-dependent and is driven by the nature of the interaction between the internal gravity waves and the inlet-driven interfacial shear. Measurements of density profile evolution have been completed for a rectangular enclosure with a single corner inlet and density variation produced by saline concentration. This system serves as a mass transfer analog to large-scale, thermally-stratified energy storage devices, preserving dynamic similitude in a laboratory-scale system. The experiments covered jet Reynolds numbers of 200-2200 and Froude numbers of 0.06-0.6 in an enclosure with a width 23 times the jet inlet height. The density profiles are seen to be strongly asymmetric and exhibit growth rates significantly different than due to simple one-dimensional molecular diffusion. In addition, shadowgraph and hydrogen bubble visualizations of the density and velocity fields in the gradient layer show the persistence of complex multi-dimensional flow structure even at relatively late stages of the filling process when the gradient layer has been transported well away from the enclosure inlet. The evolution of the vertical density profile has been compared quantitatively to a quasi one-dimensional model based upon empirical diffusivity coefficients

  1. 30 CFR 56.12068 - Locking transformer enclosures.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Locking transformer enclosures. 56.12068 Section 56.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... § 56.12068 Locking transformer enclosures. Transformer enclosures shall be kept locked against...

  2. 30 CFR 57.12068 - Locking transformer enclosures.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Locking transformer enclosures. 57.12068 Section 57.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Electricity Surface Only § 57.12068 Locking transformer enclosures. Transformer enclosures shall be kept...

  3. Acoustic absorption of natural gas compression facility enclosures

    Energy Technology Data Exchange (ETDEWEB)

    Lassen, P.; Wong, G. [Noise Management Ltd., Calgary, AB (Canada)

    2009-07-01

    Noise sources at gas compressor facilities include the enclosure/building housing a gas engine and compressor, the ventilation openings, doors and windows for the enclosure, the engine air intake and exhaust, and a cooler. Accurate predictions of the noise levels inside the enclosure, the breakout noise from open windows and doors and ventilation, as well as the transmission through the walls, is necessary in order to determine cost effective noise mitigation for the facility. In order to accurately predict the sound breakout from these facilities it is necessary to know the acoustic absorption of the interior of these equipment enclosures. Although the acoustic absorption data of the wall systems may be available, the absorption attributable to the non-enclosure surfaces, the equipment and fittings, is not usually known and is difficult to predict. Since piping, instrumentation and mechanical equipment often take on a typical arrangement, shape, volumetric density and material composition, it is useful to know the typical acoustic absorption attributable to these items. In this study, reverberation time (RT) measurements were taken at 2 decommissioned gas compressor facilities in order to determine the absorption characteristics of the enclosure. The RT was measured according to ASTM C423-02a. The overall absorption coefficient of a compressor enclosure with a solid liner was found to be similar to that of steel decking. Fittings within the enclosure did not increase the high frequency absorption of the enclosure. It was concluded that room modes, structural vibrations, and fittings may serve to increase the effective absorption at frequencies below 630 Hz. Because of the small dimensions of the enclosure, low-frequency response of the room affected the reliability of the data below 160Hz. Structural vibration of the enclosure was investigated, and may considerably influence the noise breakout from the enclosure apart from the interior acoustical considerations. 4

  4. Acoustic absorption of natural gas compression facility enclosures

    International Nuclear Information System (INIS)

    Lassen, P.; Wong, G.

    2009-01-01

    Noise sources at gas compressor facilities include the enclosure/building housing a gas engine and compressor, the ventilation openings, doors and windows for the enclosure, the engine air intake and exhaust, and a cooler. Accurate predictions of the noise levels inside the enclosure, the breakout noise from open windows and doors and ventilation, as well as the transmission through the walls, is necessary in order to determine cost effective noise mitigation for the facility. In order to accurately predict the sound breakout from these facilities it is necessary to know the acoustic absorption of the interior of these equipment enclosures. Although the acoustic absorption data of the wall systems may be available, the absorption attributable to the non-enclosure surfaces, the equipment and fittings, is not usually known and is difficult to predict. Since piping, instrumentation and mechanical equipment often take on a typical arrangement, shape, volumetric density and material composition, it is useful to know the typical acoustic absorption attributable to these items. In this study, reverberation time (RT) measurements were taken at 2 decommissioned gas compressor facilities in order to determine the absorption characteristics of the enclosure. The RT was measured according to ASTM C423-02a. The overall absorption coefficient of a compressor enclosure with a solid liner was found to be similar to that of steel decking. Fittings within the enclosure did not increase the high frequency absorption of the enclosure. It was concluded that room modes, structural vibrations, and fittings may serve to increase the effective absorption at frequencies below 630 Hz. Because of the small dimensions of the enclosure, low-frequency response of the room affected the reliability of the data below 160Hz. Structural vibration of the enclosure was investigated, and may considerably influence the noise breakout from the enclosure apart from the interior acoustical considerations. 4

  5. TECHNOLOGY FOR EFFICIENT USAGE OF HYDROCARBON-CONTAINING WASTE IN PRODUCTION OF MULTI-COMPONENT SOLID FUEL

    Directory of Open Access Journals (Sweden)

    B. M. Khroustalev

    2016-01-01

    Full Text Available The paper considers modern approaches to usage of hydrocarbon-containing waste as energy resources and presents description of investigations, statistic materials, analysis results on formation of hydrocarbon-containing waste in the Republic of Belarus. Main problems pertaining to usage of waste as a fuel and technologies for their application have been given in the paper. The paper describes main results of the investigations and a method for efficient application of viscous hydrocarbon-containing waste as an energy-packed component and a binding material while producing a solid fuel. A technological scheme, a prototype industrial unit which are necessary to realize a method for obtaining multi-component solid fuel are represented in the paper. A paper also provides a model of technological process with efficient sequence of technological operations and parameters of optimum component composition. Main factors exerting significant structure-formation influence in creation of structural composition of multi-component solid fuel have been presented in the paper. The paper gives a graphical representation of the principle for selection of mixture particles of various coarseness to form a solid fuel while using a briquetting method and comprising viscous hydrocarbon-containing waste. A dependence of dimensionless concentration g of emissions into atmosphere during burning of two-component solid fuel has been described in the paper. The paper analyzes an influence of the developed methodology for emission calculation of multi-component solid fuels and reveals a possibility to optimize the component composition in accordance with ecological function and individual peculiar features of fuel-burning equipment. Special features concerning storage and transportation, advantages and disadvantages, comparative characteristics, practical applicability of the developed multi-component solid fuel have been considered and presented in the paper. The paper

  6. Concrete material characterization reinforced concrete tank structure Multi-Function Waste Tank Facility

    International Nuclear Information System (INIS)

    Winkel, B.V.

    1995-01-01

    The purpose of this report is to document the Multi-Function Waste Tank Facility (MWTF) Project position on the concrete mechanical properties needed to perform design/analysis calculations for the MWTF secondary concrete structure. This report provides a position on MWTF concrete properties for the Title 1 and Title 2 calculations. The scope of the report is limited to mechanical properties and does not include the thermophysical properties of concrete needed to perform heat transfer calculations. In the 1970's, a comprehensive series of tests were performed at Construction Technology Laboratories (CTL) on two different Hanford concrete mix designs. Statistical correlations of the CTL data were later generated by Pacific Northwest Laboratories (PNL). These test results and property correlations have been utilized in various design/analysis efforts of Hanford waste tanks. However, due to changes in the concrete design mix and the lower range of MWTF operating temperatures, plus uncertainties in the CTL data and PNL correlations, it was prudent to evaluate the CTL data base and PNL correlations, relative to the MWTF application, and develop a defendable position. The CTL test program for Hanford concrete involved two different mix designs: a 3 kip/in 2 mix and a 4.5 kip/in 2 mix. The proposed 28-day design strength for the MWTF tanks is 5 kip/in 2 . In addition to this design strength difference, there are also differences between the CTL and MWTF mix design details. Also of interest, are the appropriate application of the MWTF concrete properties in performing calculations demonstrating ACI Code compliance. Mix design details and ACI Code issues are addressed in Sections 3.0 and 5.0, respectively. The CTL test program and PNL data correlations focused on a temperature range of 250 to 450 F. The temperature range of interest for the MWTF tank concrete application is 70 to 200 F

  7. Waste management project’s alternatives: A risk-based multi-criteria assessment (RBMCA) approach

    International Nuclear Information System (INIS)

    Karmperis, Athanasios C.; Sotirchos, Anastasios; Aravossis, Konstantinos; Tatsiopoulos, Ilias P.

    2012-01-01

    Highlights: ► We examine the evaluation of a waste management project’s alternatives. ► We present a novel risk-based multi-criteria assessment (RBMCA) approach. ► In the RBMCA the evaluation criteria are based on the quantitative risk analysis of the project’s alternatives. ► Correlation between the criteria weight values and the decision makers’ risk preferences is examined. ► Preference to the multi-criteria against the one-criterion evaluation process is discussed. - Abstract: This paper examines the evaluation of a waste management project’s alternatives through a quantitative risk analysis. Cost benefit analysis is a widely used method, in which the investments are mainly assessed through the calculation of their evaluation indicators, namely benefit/cost (B/C) ratios, as well as the quantification of their financial, technical, environmental and social risks. Herein, a novel approach in the form of risk-based multi-criteria assessment (RBMCA) is introduced, which can be used by decision makers, in order to select the optimum alternative of a waste management project. Specifically, decision makers use multiple criteria, which are based on the cumulative probability distribution functions of the alternatives’ B/C ratios. The RBMCA system is used for the evaluation of a waste incineration project’s alternatives, where the correlation between the criteria weight values and the decision makers’ risk preferences is analyzed and useful conclusions are discussed.

  8. A multi-echelon supply chain model for municipal solid waste management system

    International Nuclear Information System (INIS)

    Zhang, Yimei; Huang, Guo He; He, Li

    2014-01-01

    In this paper, a multi-echelon multi-period solid waste management system (MSWM) was developed by inoculating with multi-echelon supply chain. Waste managers, suppliers, industries and distributors could be engaged in joint strategic planning and operational execution. The principal of MSWM system is interactive planning of transportation and inventory for each organization in waste collection, delivery and disposal. An efficient inventory management plan for MSWM would lead to optimized productivity levels under available capacities (e.g., transportation and operational capacities). The applicability of the proposed system was illustrated by a case with three cities, one distribution and two waste disposal facilities. Solutions of the decision variable values under different significant levels indicate a consistent trend. With an increased significant level, the total generated waste would be decreased, and the total transported waste through distribution center to waste to energy and landfill would be decreased as well

  9. A multi-echelon supply chain model for municipal solid waste management system

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yimei, E-mail: yimei.zhang1@gmail.com [Energy and Environmental Research Academy, North China Electric Power University, Beijing 102206 (China); Huang, Guo He [Environmental Systems Engineering Program, Faculty of Engineering and Applied Science, University of Regina, Regina, Saskatchewan S4S 0A2 (Canada); He, Li [Energy and Environmental Research Academy, North China Electric Power University, Beijing 102206 (China)

    2014-02-15

    In this paper, a multi-echelon multi-period solid waste management system (MSWM) was developed by inoculating with multi-echelon supply chain. Waste managers, suppliers, industries and distributors could be engaged in joint strategic planning and operational execution. The principal of MSWM system is interactive planning of transportation and inventory for each organization in waste collection, delivery and disposal. An efficient inventory management plan for MSWM would lead to optimized productivity levels under available capacities (e.g., transportation and operational capacities). The applicability of the proposed system was illustrated by a case with three cities, one distribution and two waste disposal facilities. Solutions of the decision variable values under different significant levels indicate a consistent trend. With an increased significant level, the total generated waste would be decreased, and the total transported waste through distribution center to waste to energy and landfill would be decreased as well.

  10. A multi-echelon supply chain model for municipal solid waste management system.

    Science.gov (United States)

    Zhang, Yimei; Huang, Guo He; He, Li

    2014-02-01

    In this paper, a multi-echelon multi-period solid waste management system (MSWM) was developed by inoculating with multi-echelon supply chain. Waste managers, suppliers, industries and distributors could be engaged in joint strategic planning and operational execution. The principal of MSWM system is interactive planning of transportation and inventory for each organization in waste collection, delivery and disposal. An efficient inventory management plan for MSWM would lead to optimized productivity levels under available capacities (e.g., transportation and operational capacities). The applicability of the proposed system was illustrated by a case with three cities, one distribution and two waste disposal facilities. Solutions of the decision variable values under different significant levels indicate a consistent trend. With an increased significant level, the total generated waste would be decreased, and the total transported waste through distribution center to waste to energy and landfill would be decreased as well. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Cumulative effects, creeping enclosure, and the marine commons of New Jersey

    Directory of Open Access Journals (Sweden)

    Grant Murray

    2010-02-01

    Full Text Available In response to declining fish stocks and increased societal concern, the marine ‘commons’ of New Jersey is no longer freely available to commercial and recreational fisheries. We discuss the concept of ‘creeping’ enclosure in relation to New Jersey’s marine fisheries and suggest that reduced access can be a cumulative process and function of multiple events and processes and need not be the result of a single regulatory moment. We begin with a short review of the ‘expected’ effects of enclosure, including loss of flexibility, erosion of community, proletarianization of fishermen, and corporatization of the fishery. We then present some findings of our research and discuss how the signs of enclosure are visible in fisheries that do not feature explicitly privatized property or access rights. We rely on an oral history approach and the rich detail that emerges from attention to the lived experiences of fish harvesters to provide a framework for understanding the range of cumulative effects that have resulted from this process of creeping enclosure. We conclude with a discussion of how the gradual process of enclosure has affected the flows of information between the bio-physical environment and fish harvesters, managers and scientists by reducing both participation in fisheries and the accumulation of knowledge itself.

  12. Thermal Transmission through Existing Building Enclosures: Destructive Monitoring in Intermediate Layers versus Non-Destructive Monitoring with Sensors on Surfaces.

    Science.gov (United States)

    Echarri, Víctor; Espinosa, Almudena; Rizo, Carlos

    2017-12-08

    Opaque enclosures of buildings play an essential role in the level of comfort experienced indoors and annual energy demand. The impact of solar radiation and thermal inertia of the materials that make up the multi-layer enclosures substantially modify thermal transmittance behaviour of the enclosures. This dynamic form of heat transfer, additionally affected by indoor HVAC systems, has a substantial effect on the parameters that define comfort. It also has an impact on energy demand within a daily cycle as well as throughout a one-year use cycle. This study describes the destructive monitoring of an existing block of flats located in Alicante. Once the enclosure was opened, sensors of temperature (PT100), air velocity, and relative humidity were located in the different layers of the enclosure, as well as in the interior and exterior surfaces. A pyranometer was also installed to measure solar radiation levels. A temperature data correction algorithm was drawn up to address irregularities produced in the enclosure. The algorithm was applied using a Raspberry Pi processor in the data collection system. The comparative results of temperature gradients versus non-destructive monitoring systems are presented, providing measures of the transmittance value, surface temperatures and indoor and outdoor air temperatures. This remote sensing system can be used in future studies to quantify and compare the energy savings of different enclosure construction solutions.

  13. Thermal Transmission through Existing Building Enclosures: Destructive Monitoring in Intermediate Layers versus Non-Destructive Monitoring with Sensors on Surfaces

    Directory of Open Access Journals (Sweden)

    Víctor Echarri

    2017-12-01

    Full Text Available Opaque enclosures of buildings play an essential role in the level of comfort experienced indoors and annual energy demand. The impact of solar radiation and thermal inertia of the materials that make up the multi-layer enclosures substantially modify thermal transmittance behaviour of the enclosures. This dynamic form of heat transfer, additionally affected by indoor HVAC systems, has a substantial effect on the parameters that define comfort. It also has an impact on energy demand within a daily cycle as well as throughout a one-year use cycle. This study describes the destructive monitoring of an existing block of flats located in Alicante. Once the enclosure was opened, sensors of temperature (PT100, air velocity, and relative humidity were located in the different layers of the enclosure, as well as in the interior and exterior surfaces. A pyranometer was also installed to measure solar radiation levels. A temperature data correction algorithm was drawn up to address irregularities produced in the enclosure. The algorithm was applied using a Raspberry Pi processor in the data collection system. The comparative results of temperature gradients versus non-destructive monitoring systems are presented, providing measures of the transmittance value, surface temperatures and indoor and outdoor air temperatures. This remote sensing system can be used in future studies to quantify and compare the energy savings of different enclosure construction solutions.

  14. Thermal Transmission through Existing Building Enclosures: Destructive Monitoring in Intermediate Layers versus Non-Destructive Monitoring with Sensors on Surfaces

    Science.gov (United States)

    Echarri, Víctor; Espinosa, Almudena; Rizo, Carlos

    2017-01-01

    Opaque enclosures of buildings play an essential role in the level of comfort experienced indoors and annual energy demand. The impact of solar radiation and thermal inertia of the materials that make up the multi-layer enclosures substantially modify thermal transmittance behaviour of the enclosures. This dynamic form of heat transfer, additionally affected by indoor HVAC systems, has a substantial effect on the parameters that define comfort. It also has an impact on energy demand within a daily cycle as well as throughout a one-year use cycle. This study describes the destructive monitoring of an existing block of flats located in Alicante. Once the enclosure was opened, sensors of temperature (PT100), air velocity, and relative humidity were located in the different layers of the enclosure, as well as in the interior and exterior surfaces. A pyranometer was also installed to measure solar radiation levels. A temperature data correction algorithm was drawn up to address irregularities produced in the enclosure. The algorithm was applied using a Raspberry Pi processor in the data collection system. The comparative results of temperature gradients versus non-destructive monitoring systems are presented, providing measures of the transmittance value, surface temperatures and indoor and outdoor air temperatures. This remote sensing system can be used in future studies to quantify and compare the energy savings of different enclosure construction solutions. PMID:29292781

  15. Heat transfer effects in vertically emplaced high level nuclear waste container

    International Nuclear Information System (INIS)

    Moujaes, S.F.; Lei, Y.M.

    1994-01-01

    Modeling free convection heat transfer in a cylindrical annular enclosure is still an active area of research and an important problem to be addressed in the high level nuclear waste repository. For the vertically emplaced waste container, the air gap which is between the container shell and the rock borehole, have an important role of dissipating heat to surrounding rock. These waste containers are vertically emplaced in the borehole 300 meters just below ground, and in a horizontal grid of 30 x 8 meters apart. The borehole will be capped after the container emplacement. The expected initial heat generated is between 3-4.74 kW per container depending on the type of waste. The goal of this study is to use a computer simulation model to find the borehole wall, air-gap and the container outer wall temperature distributions. The borehole wall temperature history has been found in the previous study, and was estimated to reach a maximum temperature of about 218 degrees C after 18 years from the emplacement. The temperature history of the rock surface is then used for the air-gap simulation. The problem includes convection and radiation heat transfer in a vertical enclosure. This paper will present the results of the convection in the air-gap over one thousand years after the containers' emplacement. During this long simulation period it was also observed that a multi-cellular air flow pattern can be generated in the air gap

  16. Use of base isolation techniques for the design of high-level waste storage facility enclosure at INEL

    International Nuclear Information System (INIS)

    Vallenas, J.M.; Wong, Chun K.; Beer, M.J.

    1993-08-01

    Current Department of Energy criteria for facilities subjected to natural hazards provide guidelines to place facilities or portions of facilities into usage categories. Usage categories are based on characteristics such as mission dependence, type of hazardous materials involved, and performance goals. Seismic requirements are significantly more stringent for facilities falling into higher ''hazard facility use categories''. A special problem arises in cases where a facility or portion of a facility is dependent on another facility of lower ''hazard facility use category'' for support or protection. Creative solutions can minimize the cost Unpact of ensuring that the lower category item does not compromise the performance of the higher category item. In this paper, a base isolation solution is provided for a ''low hazard facility use category'' weather enclosure designed so it will not collapse onto a ''high hazard facility use category'' high level waste storage facility at INEL. This solution is compared to other more conventional procedures. Details, practical limitations, licensing and regulatory considerations, and cost comparisons are provided

  17. Nuclear power plant with a safety enclosure

    International Nuclear Information System (INIS)

    Keller, W.; Krueger, J.; Ropers, J.; Schabert, H.P.

    1976-01-01

    A nuclear power plant has a safety enclosure for a nuclear reactor. A fuel element storage basin is also located in this safety enclosure and a fuel element lock extends through the enclosure, with a cross-sectional size proportioned for the endwise passage of fuel elements, the lock including internal and external valves so that a fuel element may be locked endwise safely through the lock. The lock, including its valves, being of small size, does not materially affect the pressure resistance of the safety enclosure, and it is more easily operated than a lock large enough to pass people and fuel element transport vessels

  18. Natural convection in wavy enclosures with volumetric heat sources

    International Nuclear Information System (INIS)

    Oztop, H.F.; Varol, Y.; Abu-Nada, E.; Chamkha, A.

    2011-01-01

    In this paper, the effects of volumetric heat sources on natural convection heat transfer and flow structures in a wavy-walled enclosure are studied numerically. The governing differential equations are solved by an accurate finite-volume method. The vertical walls of enclosure are assumed to be heated differentially whereas the two wavy walls (top and bottom) are kept adiabatic. The effective governing parameters for this problem are the internal and external Rayleigh numbers and the amplitude of wavy walls. It is found that both the function of wavy wall and the ratio of internal Rayleigh number (Ra I ) to external Rayleigh number (Ra E ) affect the heat transfer and fluid flow significantly. The heat transfer is predicted to be a decreasing function of waviness of the top and bottom walls in case of (IRa/ERa)>1 and (IRa/ERa)<1. (authors)

  19. Components for containment enclosures. Part 4: Ventilation and gas-cleaning systems such as filters, traps, safety and regulation valves, control and protection devices

    International Nuclear Information System (INIS)

    2001-01-01

    ISO 11933 consists of the following parts, under the general title Components for containment enclosures: Part 1: Glove/bag ports, bungs for glove/bag ports, enclosure rings and interchangeable units; Part 2: Gloves, welded bags, gaiters for remote-handling tongs and for manipulators; Part 3: Transfer systems such as plain doors, airlock chambers, double door transfer systems, leaktight connections for waste drums; Part 4: Ventilation and gas-cleaning systems such as filters, traps, safety and regulation valves, control and protection devices; Part 5: Penetrations for electrical and fluid circuits. This part of ISO 11933 specifies the design criteria and the characteristics of various components used for ventilation and gas-cleaning in containment enclosures. These components are either directly fixed to the containment enclosure wall, or used in the environment of a shielded or unshielded containment enclosure or line of such enclosures. They can be used alone or in conjunction with other mechanical components, including those specified in ISO 11933-1 and ISO 11933-3. This part of ISO 11933 is applicable to: filtering devices, including high-efficiency particulate air (HEPA) filters and iodine traps; safety valves and pressure regulators; systems ensuring the mechanical protection of containment enclosures; control and pressure-measurement devices

  20. An Improvement in Biodiesel Production from Waste Cooking Oil by Applying Thought Multi-Response Surface Methodology Using Desirability Functions

    Directory of Open Access Journals (Sweden)

    Marina Corral Bobadilla

    2017-01-01

    Full Text Available The exhaustion of natural resources has increased petroleum prices and the environmental impact of oil has stimulated the search for an alternative source of energy such as biodiesel. Waste cooking oil is a potential replacement for vegetable oils in the production of biodiesel. Biodiesel is synthesized by direct transesterification of vegetable oils, which is controlled by several inputs or process variables, including the dosage of catalyst, process temperature, mixing speed, mixing time, humidity and impurities of waste cooking oil that was studied in this case. Yield, turbidity, density, viscosity and higher heating value are considered as outputs. This paper used multi-response surface methodology (MRS with desirability functions to find the best combination of input variables used in the transesterification reactions to improve the production of biodiesel. In this case, several biodiesel optimization scenarios have been proposed. They are based on a desire to improve the biodiesel yield and the higher heating value, while decreasing the viscosity, density and turbidity. The results demonstrated that, although waste cooking oil was collected from various sources, the dosage of catalyst is one of the most important variables in the yield of biodiesel production, whereas the viscosity obtained was similar in all samples of the biodiesel that was studied.

  1. 50 CFR 14.142 - Primary enclosures.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 1 2010-10-01 2010-10-01 false Primary enclosures. 14.142 Section 14.142 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR TAKING... outside the enclosure. Specifications for Sloths, Bats, and Flying Lemurs (Cynocephalidae) ...

  2. Design of multi-function Hanford tank corrosion monitoring system

    International Nuclear Information System (INIS)

    EDGEMON, G.L.

    1999-01-01

    A multi-fiction corrosion monitoring system has been designed for installation into DST 241-AN-105 at the Hanford Site in fiscal year 1999. The 241-AN-105 system is the third-generation corrosion monitoring system described by TTP RLO-8-WT-21. Improvements and upgrades from the second-generation system (installed in 241-AN-102) that have been incorporated into the third-generation system include: Gasket seating surfaces utilize O-rings instead of a washer type gasket for improved seal; Probe design contains an equally spaced array of 22 thermocouples; Probe design contains an adjustable verification thermocouple; Probe design contains three ports for pressure/gas sampling; Probe design contains one set of strain gauges to monitor probe flexure if flexure occurs; Probe utilizes an adjustable collar to allow depth adjustment of probe during installation; System is capable of periodically conducting LPR scans; System is housed in a climate controlled enclosure adjacent to the riser containing the probe; System uses wireless Ethernet links to send data to Hanford Local Area Network; System uses commercial remote access software to allow remote command and control; and Above ground wiring uses driven shields to reduce external electrostatic noise in the data. These new design features have transformed what was primarily a second-generation corrosion monitoring system into a multi-function tank monitoring system that adds a great deal of functionality to the probe, provides for a better understanding of the relationship between corrosion and other tank operating parameters, and optimizes the use of the riser that houses the probe in the tank

  3. The 3.5-Meter Telescope Enclosure

    Science.gov (United States)

    1994-04-01

    and acoustic vibrations, and the enclosure cannot be stopped quickly in an emergency. Also, the work of Zago indicates that open-air operation of the...enclosure. This capability is useful during operational testing and maintenance of the telescope. ’ Zago , L., "Design and Performance of Large

  4. Humidity evolution (breathing effect) in enclosures with electronics

    DEFF Research Database (Denmark)

    Hygum, Morten Arnfeldt; Popok, Vladimir

    2015-01-01

    Packaging and enclosures used for protecting power electronics operating outdoors are designed to withstand the local climatic and environmental changes. Hermetic enclosures are expensive and therefore other solutions for protecting the electronics from a harsh environment are required. One...... of the dangerous parameters is high humidity of air. Moisture can inevitable reach the electronics either due to diffusion through the wall of an enclosure or small holes, which are designed for electrical or other connections. A driving force for humid air movement is the temperature difference between...... the operating electronics and the surrounding environment. This temperature, thus, gives rise to a natural convection, which we also refer to as breathing. Robust and intelligent enclosure designs must account for this breathing as it can significantly change the humidity distribution in the enclosure...

  5. Limiting enclosures - Filtering fittings for air or gas

    International Nuclear Information System (INIS)

    1981-05-01

    The aim of this experimental standard is the determination of the general characteristics of air or gas filtration equipment for limiting enclosures in application of the standard M 62-202. Application are made on enclosures or enclosure lines used for works on radioactive materials, toxic or dangerous chemicals, materials sensitive to atmospheric components or requiring a steril atmosphere [fr

  6. DKIST enclosure modeling and verification during factory assembly and testing

    Science.gov (United States)

    Larrakoetxea, Ibon; McBride, William; Marshall, Heather K.; Murga, Gaizka

    2014-08-01

    The Daniel K. Inouye Solar Telescope (DKIST, formerly the Advanced Technology Solar Telescope, ATST) is unique as, apart from protecting the telescope and its instrumentation from the weather, it holds the entrance aperture stop and is required to position it with millimeter-level accuracy. The compliance of the Enclosure design with the requirements, as of Final Design Review in January 2012, was supported by mathematical models and other analyses which included structural and mechanical analyses (FEA), control models, ventilation analysis (CFD), thermal models, reliability analysis, etc. During the Enclosure Factory Assembly and Testing the compliance with the requirements has been verified using the real hardware and the models created during the design phase have been revisited. The tests performed during shutter mechanism subsystem (crawler test stand) functional and endurance testing (completed summer 2013) and two comprehensive system-level factory acceptance testing campaigns (FAT#1 in December 2013 and FAT#2 in March 2014) included functional and performance tests on all mechanisms, off-normal mode tests, mechanism wobble tests, creation of the Enclosure pointing map, control system tests, and vibration tests. The comparison of the assumptions used during the design phase with the properties measured during the test campaign provides an interesting reference for future projects.

  7. MROI Array telescopes: the relocatable enclosure domes

    Science.gov (United States)

    Marchiori, G.; Busatta, A.; Payne, I.

    2016-07-01

    The MROI - Magdalena Ridge Interferometer is a project which comprises an array of up to 10 1.4m diameter mirror telescopes arranged in a "Y" configuration. Each of these telescopes will be housed inside a Unit Telescope Enclosure (UTE) which are relocatable onto any of 28 stations. EIE GROUP Srl, Venice - Italy, was awarded the contract for the design, the construction and the erection on site of the MROI by the New Mexico Institute of Mining and Technology. The close-pack array of the MROI - including all 10 telescopes, several of which are at a relative distance of less than 8m center to center from each other - necessitated an original design for the Unit Telescope Enclosure (UTE). This innovative design enclosure incorporates a unique dome/observing aperture system to be able to operate in the harsh environmental conditions encountered at an altitude of 10,460ft (3,188m). The main characteristics of this Relocatable Enclosure Dome are: a Light insulated Steel Structure with a dome made of composites materials (e.g. glass/carbon fibers, sandwich panels etc.), an aperture motorized system for observation, a series of louvers for ventilation, a series of electrical and plants installations and relevant auxiliary equipment. The first Enclosure Dome is now under construction and the completion of the mounting on site id envisaged by the end of 2016. The relocation system utilizes a modified reachstacker (a transporter used to handle freight containers) capable of maneuvering between and around the enclosures, capable of lifting the combined weight of the enclosure with the telescope (30tons), with minimal impacts due to vibrations.

  8. 40 CFR 86.117-96 - Evaporative emission enclosure calibrations.

    Science.gov (United States)

    2010-07-01

    ... periodic determination of enclosure background emissions. Prior to its introduction into service, annually... procedure: (1) Carefully measure the internal length, width and height of the enclosure, accounting for... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Evaporative emission enclosure...

  9. Constructal design of phase change material enclosures used for cooling electronic devices

    International Nuclear Information System (INIS)

    Kalbasi, Rasool; Salimpour, Mohammad Reza

    2015-01-01

    Recent developments in cooling methods for portable electronic devices have heightened the need for using the large latent heat capacity of phase change materials (PCM). The aim of the present study is to evaluate the thermal characteristics of a PCM-based heat sink with high conductive materials. The solution is acquired as a procession of optimization stages which starts with the elemental area and proceeds toward the first assembly. Every optimization stage is the result of maximizing the safe operation time without allowing the electronics to reach the critical temperature. Primarily, the degrees of freedom and constrains were defined and then by changing the geometrical parameters, the target function which is the maximization of operation time, was optimized. Results show that the melting process in rectangular enclosures with vertical fins attached to the heated bottom surface can be affected by the contact surface between the fin and PCM and the convection of the melted PCM. For a rectangular enclosure with a constant area, it is better to use wider enclosure than the square and thin one. Also results indicate that the ratio of the vertical fin thickness to the horizontal one does not have a considerable effect on performance. By increasing the number of enclosures, the contact surface is raised, but the performance is not necessarily improved. - Highlights: • Thermal characteristics of a finned PCM-based heat sink are studied. • Constructal theory was used to optimize the PCM enclosures. • By increasing the number of enclosures, the performance is not necessarily improved

  10. Optimal acid digestion for multi-element analysis of different waste matrices

    DEFF Research Database (Denmark)

    Götze, Ramona; Astrup, Thomas Fruergaard

    of the distinct waste materials and recyclables. The purpose of this study is to evaluate the performance of different standardized microwave assisted acid digestion methods on waste samples and subsequent multi-element analysis. Six acid digestion methods were applied on a Paper & Cardboard and Composite waste...

  11. Industrial applications of multi-functional, multi-phase reactors

    NARCIS (Netherlands)

    Harmsen, G.J.; Chewter, L.A.

    1999-01-01

    To reveal trends in the design and operation of multi-functional, multi-phase reactors, this paper describes, in historical sequence, three industrial applications of multi-functional, multi-phase reactors developed and operated by Shell Chemicals during the last five decades. For each case, we

  12. Shielded enclosure for handling radioactive material

    International Nuclear Information System (INIS)

    Laurent, H.; Courouble, J.M.

    1959-01-01

    Two enclosures linked by an air-lock are described: they are designed for the safe handling of 5 curies 0.3 to 0.5 MeV γ emitters, and each is composed of a semi-tight case, ventilated, clad in 80 mm steel plate, and suited for a wide variety of physics and chemistry operations. The equipment required for any given operation can be installed in the shortest possible time, access to the enclosure being via a removable front. Visual control is assured through a lead-glass screen. Each enclosure is fitted with a master-slave manipulator, Argon model 7, and plugs and air-locks are provided for the introduction of liquids and solids. (author) [fr

  13. An Improved Multi-Objective Programming with Augmented ε-Constraint Method for Hazardous Waste Location-Routing Problems.

    Science.gov (United States)

    Yu, Hao; Solvang, Wei Deng

    2016-05-31

    Hazardous waste location-routing problems are of importance due to the potential risk for nearby residents and the environment. In this paper, an improved mathematical formulation is developed based upon a multi-objective mixed integer programming approach. The model aims at assisting decision makers in selecting locations for different facilities including treatment plants, recycling plants and disposal sites, providing appropriate technologies for hazardous waste treatment, and routing transportation. In the model, two critical factors are taken into account: system operating costs and risk imposed on local residents, and a compensation factor is introduced to the risk objective function in order to account for the fact that the risk level imposed by one type of hazardous waste or treatment technology may significantly vary from that of other types. Besides, the policy instruments for promoting waste recycling are considered, and their influence on the costs and risk of hazardous waste management is also discussed. The model is coded and calculated in Lingo optimization solver, and the augmented ε-constraint method is employed to generate the Pareto optimal curve of the multi-objective optimization problem. The trade-off between different objectives is illustrated in the numerical experiment.

  14. An Improved Multi-Objective Programming with Augmented ε-Constraint Method for Hazardous Waste Location-Routing Problems

    Directory of Open Access Journals (Sweden)

    Hao Yu

    2016-05-01

    Full Text Available Hazardous waste location-routing problems are of importance due to the potential risk for nearby residents and the environment. In this paper, an improved mathematical formulation is developed based upon a multi-objective mixed integer programming approach. The model aims at assisting decision makers in selecting locations for different facilities including treatment plants, recycling plants and disposal sites, providing appropriate technologies for hazardous waste treatment, and routing transportation. In the model, two critical factors are taken into account: system operating costs and risk imposed on local residents, and a compensation factor is introduced to the risk objective function in order to account for the fact that the risk level imposed by one type of hazardous waste or treatment technology may significantly vary from that of other types. Besides, the policy instruments for promoting waste recycling are considered, and their influence on the costs and risk of hazardous waste management is also discussed. The model is coded and calculated in Lingo optimization solver, and the augmented ε-constraint method is employed to generate the Pareto optimal curve of the multi-objective optimization problem. The trade-off between different objectives is illustrated in the numerical experiment.

  15. Clearance of radioactive materials during reactor dismantling. Permanent enclosure instead of demolition and renaturation?

    International Nuclear Information System (INIS)

    2016-01-01

    During reactor dismantling besides high-level radioactive wastes a large amount of low-level contaminated steel and concrete has to be disposed. In case that radioactivity falls below defined dose limits (10 micro Sv/person and year) these materials may be disposed in domestic waste landfill or in municipal incineration facilities. The issue is discussed in detail including the fact that many power plants are dismantled at the same time so that the contaminated materials might accumulate. Another issue is the occupational safety of contract workers during dismantling. The permanent enclosure could avoid this environmental contamination of decommissioned power plants might also be less expensive.

  16. Track plate enclosures: Box designs affecting attractiveness to riparian mammals

    Science.gov (United States)

    Loukmas, J.J.; Mayack, D.T.; Richmond, M.E.

    2003-01-01

    We examined the efficacy of four track plate enclosure designs for monitoring the abundance of small and medium-sized mammals along 10 streams in New York State. Box size and clarity of view through the box were evaluated as factors affecting visitation. We checked track plate stations weekly from September 1999 to March 2000. Eleven mammalian species or species groups visited the track plate stations. Raccoons (Procyon lotor) (P = 0.020) and feral cats (Felis catus) (P = 0.008) visited large enclosures significantly more than small enclosures. Feral cats visited clear-view enclosures significantly more than obstructed-view enclosures (P = 0.025). Enclosure size and view did not significantly affect visitation by other species; however, a large box with a clear view was the most effective design.

  17. A multi-objective approach to solid waste management

    International Nuclear Information System (INIS)

    Galante, Giacomo; Aiello, Giuseppe; Enea, Mario; Panascia, Enrico

    2010-01-01

    The issue addressed in this paper consists in the localization and dimensioning of transfer stations, which constitute a necessary intermediate level in the logistic chain of the solid waste stream, from municipalities to the incinerator. Contextually, the determination of the number and type of vehicles involved is carried out in an integrated optimization approach. The model considers both initial investment and operative costs related to transportation and transfer stations. Two conflicting objectives are evaluated, the minimization of total cost and the minimization of environmental impact, measured by pollution. The design of the integrated waste management system is hence approached in a multi-objective optimization framework. To determine the best means of compromise, goal programming, weighted sum and fuzzy multi-objective techniques have been employed. The proposed analysis highlights how different attitudes of the decision maker towards the logic and structure of the problem result in the employment of different methodologies and the obtaining of different results. The novel aspect of the paper lies in the proposal of an effective decision support system for operative waste management, rather than a further contribution to the transportation problem. The model was applied to the waste management of optimal territorial ambit (OTA) of Palermo (Italy).

  18. A multi-objective approach to solid waste management.

    Science.gov (United States)

    Galante, Giacomo; Aiello, Giuseppe; Enea, Mario; Panascia, Enrico

    2010-01-01

    The issue addressed in this paper consists in the localization and dimensioning of transfer stations, which constitute a necessary intermediate level in the logistic chain of the solid waste stream, from municipalities to the incinerator. Contextually, the determination of the number and type of vehicles involved is carried out in an integrated optimization approach. The model considers both initial investment and operative costs related to transportation and transfer stations. Two conflicting objectives are evaluated, the minimization of total cost and the minimization of environmental impact, measured by pollution. The design of the integrated waste management system is hence approached in a multi-objective optimization framework. To determine the best means of compromise, goal programming, weighted sum and fuzzy multi-objective techniques have been employed. The proposed analysis highlights how different attitudes of the decision maker towards the logic and structure of the problem result in the employment of different methodologies and the obtaining of different results. The novel aspect of the paper lies in the proposal of an effective decision support system for operative waste management, rather than a further contribution to the transportation problem. The model was applied to the waste management of optimal territorial ambit (OTA) of Palermo (Italy). 2010 Elsevier Ltd. All rights reserved.

  19. Strategy to develop and test a multi-function scarifier end effector with an integral conveyance system for waste tank remediation

    International Nuclear Information System (INIS)

    Bamberger, J.A.; Bates, J.M.; Keska, J.K.; Elmore, M.R.; Lombardo, N.J.

    1993-08-01

    This strategy plan describes a coupled analytical/experimental approach to develop a multi-functional scarifier end effector coupled with a pneumatic conveyance system to retrieve wastes from underground storage tanks. The scarifier uses ultra-high-pressure water jets to rubblize and entrain waste forms such as salt cake, sludge, and viscous liquid that can be transported pneumatically. The three waste types (hard, brittle, salt cake, viscous liquid, and deformable sludge) present increasingly complex challenges for scarification and pneumatic conveyance. Salt cake is anticipated to be the easiest to retrieve because (1) a theoretical model of hydraulic rock fracture can be applied to estimate jet performance to fracture salt cake, and (2) gas-solids transport correlations can be used to predict pneumatic transport. Deformable sludge is anticipated to be the most difficult to retrieve: no theories, correlations, or data exist to predict this performance. However order-of-magnitude gas-solid correlations indicate particulate wastes of prototypic density can be transported to a height of 20 m within allowable pressure limits provided that the volume fraction of the gaseous phase is kept above 95%. Viscous liquid is anticipated to be of intermediate complexity to retrieve. Phenomena that are expected to affect system performance are ranked. Experiments and analyses necessary to evaluate the effects of these phenomena are proposed. Subsequent strategies for experiment test plans, system deployment, and operation and control will need to be developed

  20. Effects of a new molt-inducing insecticide, tebufenozide, on zooplankton communities in lake enclosures.

    Science.gov (United States)

    Kreutzweiser, D P; Thomas, D R

    1995-10-01

    : A potent ecdysone agonist, tebufenozide, has recently been developed as a molt-inducing insecticide to control defoliating lepidopterans. As part of continuing research efforts to assess the effectiveness and environmental safety of this material for insect pest management in Canadian forests, tebufenozide (RH-5992-2F) was applied to large lake enclosures and the effects on zooplankton communities were evaluated. There were significant treatment effects at all test concentrations (0.07-0.66 mg L(-1) tebufenozide). Concentration-dependent reductions in the abundance of cladocerans indicated that there were direct toxic effects of tebufenozide on this group of macrozooplankton. There were no indications of direct toxic effects on copepods. Significant increases in abundance of rotifers in treated enclosures at the three higher test concentrations were coincident with reductions in cladocerans and indicated secondary effects of the insecticide on the abundance of microzooplankton. There were no significant differences among treated and control enclosures in chlorophyll a concentrations, indicating that tebufenozide did not have direct effects on phytoplankton biomass, nor did the alterations in the zooplankton communities of treated enclosures have measurable secondary effects on phytoplankton biomass. Daytime dissolved oxygen concentrations were significantly higher in treated enclosures than in controls, indicating that the perturbation to biotic communities of some treated enclosures was sufficient to induce measurable changes in system-level functional attributes. Recovery of zooplankton communities in the enclosures occurred within 1-2 months at 0.07 and 0.13 mg l(-1) and by the following summer (12-13 months) at 0.33 and 0.66 mg l(-1).

  1. Enclosure enhancement of flight performance

    KAUST Repository

    Ghommem, Mehdi; Garcia, Daniel; Calo, Victor M.

    2014-01-01

    We use a potential flow solver to investigate the aerodynamic aspects of flapping flights in enclosed spaces. The enclosure effects are simulated by the method of images. Our study complements previous aerodynamic analyses which considered only the near-ground flight. The present results show that flying in the proximity of an enclosure affects the aerodynamic performance of flapping wings in terms of lift and thrust generation and power consumption. It leads to higher flight efficiency and more than 5% increase of the generation of lift and thrust.

  2. Enclosure enhancement of flight performance

    KAUST Repository

    Ghommem, Mehdi

    2014-08-19

    We use a potential flow solver to investigate the aerodynamic aspects of flapping flights in enclosed spaces. The enclosure effects are simulated by the method of images. Our study complements previous aerodynamic analyses which considered only the near-ground flight. The present results show that flying in the proximity of an enclosure affects the aerodynamic performance of flapping wings in terms of lift and thrust generation and power consumption. It leads to higher flight efficiency and more than 5% increase of the generation of lift and thrust.

  3. A new neolithic circular enclosure in Central Germany

    Science.gov (United States)

    Kretzer, Olaf

    2015-08-01

    Today we know about 130 neolithic enclosures in Central Europe. About 20 of them are located in Germany. In the last years, there was a great discussion about the function of the openings: Are the openings aligned with points of the solstices? Or are the openings aligned with points of rising stars?Four years ago, a new neolithic circular enclosure was found in the northern part of Thuringia. With a diameter of about 50 meters it was not so large but it was the first evidence of a neolithic culture in Thuringia: the central part of Germany!7000 years ago, people with unknown identity built up three rings with three or four openings.With the help of various measurements we were able to determine in which directions the openings were aligned. We found a link between these directions and very interesting landmarks - an amazing connection between sky and landscape.

  4. Enclosure enhancement of flight performance

    Directory of Open Access Journals (Sweden)

    Mehdi Ghommem

    2014-01-01

    Full Text Available We use a potential flow solver to investigate the aerodynamic aspects of flapping flights in enclosed spaces. The enclosure effects are simulated by the method of images. Our study complements previous aerodynamic analyses which considered only the near-ground flight. The present results show that flying in the proximity of an enclosure affects the aerodynamic performance of flapping wings in terms of lift and thrust generation and power consumption. It leads to higher flight efficiency and more than 5% increase of the generation of lift and thrust.

  5. Preliminary Safety Analysis Report for the Transuranic Storage Area Retrieval Enclosure at the Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    1993-03-01

    This Transuranic Storage Area Retrieval Enclosure Preliminary Safety Analysis Report was completed as required by DOE Order 5480.23. The purpose of this document is to construct a safety basis that supports the design and permits construction of the facility. The facility has been designed to the requirements of a Radioactive Solid Waste Facility presented in DOE Order 6430.1A

  6. 30 CFR 75.819 - Motor-starter enclosures; barriers and interlocks.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Motor-starter enclosures; barriers and...-Voltage Distribution High-Voltage Longwalls § 75.819 Motor-starter enclosures; barriers and interlocks. Compartment separation and cover interlock switches for motor-starter enclosures must be maintained in...

  7. Multi-color pyrometry imaging system and method of operating the same

    Science.gov (United States)

    Estevadeordal, Jordi; Nirmalan, Nirm Velumylum; Tralshawala, Nilesh; Bailey, Jeremy Clyde

    2017-03-21

    A multi-color pyrometry imaging system for a high-temperature asset includes at least one viewing port in optical communication with at least one high-temperature component of the high-temperature asset. The system also includes at least one camera device in optical communication with the at least one viewing port. The at least one camera device includes a camera enclosure and at least one camera aperture defined in the camera enclosure, The at least one camera aperture is in optical communication with the at least one viewing port. The at least one camera device also includes a multi-color filtering mechanism coupled to the enclosure. The multi-color filtering mechanism is configured to sequentially transmit photons within a first predetermined wavelength band and transmit photons within a second predetermined wavelength band that is different than the first predetermined wavelength band.

  8. Ventilation of radioactive enclosures

    International Nuclear Information System (INIS)

    Caminade, F.; Laurent, H.

    1957-01-01

    Mechanical, physical and chemical manipulations on radioactive products must be carried out in properly ventilated enclosed places. The air extracted can only be discharged into the atmosphere after a correct filtration. The power of the ventilation systems is a function of the dimensions and purpose of the enclosure? The choice of types of filter is determined by the physical state and chemical nature of the radioactive materials to be manipulated. This study deals with the individual equipment of small installations: glove boxes, manipulation boxes with outside control and, if necessary, production chambers (maximum useful volume: 5 m 3 ). The performances of three types of 'ventilators', and the modifications provided by the addition of filters, are measured and compared. (author) [fr

  9. Multi-criteria decision making to support waste management: A critical review of current practices and methods.

    Science.gov (United States)

    Goulart Coelho, Lineker M; Lange, Liséte C; Coelho, Hosmanny Mg

    2017-01-01

    Solid waste management is a complex domain involving the interaction of several dimensions; thus, its analysis and control impose continuous challenges for decision makers. In this context, multi-criteria decision-making models have become important and convenient supporting tools for solid waste management because they can handle problems involving multiple dimensions and conflicting criteria. However, the selection of the multi-criteria decision-making method is a hard task since there are several multi-criteria decision-making approaches, each one with a large number of variants whose applicability depends on information availability and the aim of the study. Therefore, to support researchers and decision makers, the objectives of this article are to present a literature review of multi-criteria decision-making applications used in solid waste management, offer a critical assessment of the current practices, and provide suggestions for future works. A brief review of fundamental concepts on this topic is first provided, followed by the analysis of 260 articles related to the application of multi-criteria decision making in solid waste management. These studies were investigated in terms of the methodology, including specific steps such as normalisation, weighting, and sensitivity analysis. In addition, information related to waste type, the study objective, and aspects considered was recorded. From the articles analysed it is noted that studies using multi-criteria decision making in solid waste management are predominantly addressed to problems related to municipal solid waste involving facility location or management strategy.

  10. Status analysis of Chinese standards on enclosure equipment and proposed countermeasures

    International Nuclear Information System (INIS)

    Wu Luping

    1998-12-01

    Enclosure equipment, such as glove box, tong box etc., is an important kind of equipment for nuclear industry and nuclear scientific research. The status of the establishment and implementation of Chinese standards on enclosure equipment is briefly described. Some problems and deficiency existing in these standards are pointed out. The ISO standard projects on containment enclosures as well as their present progress situations are introduced. The measure for updating Chinese standards on enclosure equipment in accordance with the principle of adopting international standards are recommended. Some issues which should be taken into account in adopting ISO standards on containment enclosures are also discussed

  11. Application of multi-criteria decision-making on strategic municipal solid waste management in Dalmatia, Croatia

    International Nuclear Information System (INIS)

    Vego, Goran; Kucar-Dragicevic, Savka; Koprivanac, Natalija

    2008-01-01

    The efficiency of providing a waste management system in the coastal part of Croatia consisting of four Dalmatian counties has been modelled. Two multi-criteria decision-making (MCDM) methods, PROMETHEE and GAIA, were applied to assist with the systematic analysis and evaluation of the alternatives. The analysis covered two levels; first, the potential number of waste management centres resulting from possible inter-county cooperation; and second, the relative merits of siting of waste management centres in the coastal or hinterland zone was evaluated. The problem was analysed according to several criteria; and ecological, economic, social and functional criteria sets were identified as relevant to the decision-making process. The PROMETHEE and GAIA methods were shown to be efficient tools for analysing the problem considered. Such an approach provided new insights to waste management planning at the strategic level, and gave a reason for rethinking some of the existing strategic waste management documents in Croatia

  12. Application of multi-criteria decision-making on strategic municipal solid waste management in Dalmatia, Croatia.

    Science.gov (United States)

    Vego, Goran; Kucar-Dragicević, Savka; Koprivanac, Natalija

    2008-11-01

    The efficiency of providing a waste management system in the coastal part of Croatia consisting of four Dalmatian counties has been modelled. Two multi-criteria decision-making (MCDM) methods, PROMETHEE and GAIA, were applied to assist with the systematic analysis and evaluation of the alternatives. The analysis covered two levels; first, the potential number of waste management centres resulting from possible inter-county cooperation; and second, the relative merits of siting of waste management centres in the coastal or hinterland zone was evaluated. The problem was analysed according to several criteria; and ecological, economic, social and functional criteria sets were identified as relevant to the decision-making process. The PROMETHEE and GAIA methods were shown to be efficient tools for analysing the problem considered. Such an approach provided new insights to waste management planning at the strategic level, and gave a reason for rethinking some of the existing strategic waste management documents in Croatia.

  13. Enclosure for handling high activity materials

    International Nuclear Information System (INIS)

    Jimeno de Osso, F.

    1977-01-01

    One of the most important problems that are met at the laboratories producing and handling radioisotopes is that of designing, building and operating enclosures suitable for the safe handling of active substances. With this purpose in mind, an enclosure has been designed and built for handling moderately high activities under a shielding made of 150 mm thick lead. In this report a description is given of those aspects that may be of interest to people working in this field. (Author)

  14. Enclosure for handling high activity materials

    Energy Technology Data Exchange (ETDEWEB)

    Jimeno de Osso, F

    1977-07-01

    One of the most important problems that are met at the laboratories producing and handling radioisotopes is that of designing, building and operating enclosures suitable for the safe handling of active substances. With this purpose in mind, an enclosure has been designed and built for handling moderately high activities under a shielding made of 150 mm thick lead. In this report a description is given of those aspects that may be of interest to people working in this field. (Author)

  15. Humidity Build-Up in a Typical Electronic Enclosure Exposed to Cycling Conditions and Effect on Corrosion Reliability

    DEFF Research Database (Denmark)

    Conseil, Helene; Gudla, Visweswara Chakravarthy; Jellesen, Morten Stendahl

    2016-01-01

    The design of electronic device enclosures plays a major role in determining the humidity build-up inside the device as a response to the varying external humidity. Therefore, the corrosion reliability of electronic devices has direct connection to the enclosure design. This paper describes......, thermal mass, and port/opening size. The effect of the internal humidity build-up on corrosion reliability has been evaluated by measuring the leakage current (LC) on interdigitated test comb patterns, which are precontaminated with sodium chloride and placed inside the enclosure. The results showed...... that the exposure to cycling temperature causes significant change of internal water vapor concentration. The maximum value of humidity reached was a function of the opening size and the presence of thermal mass inside the enclosure. A pumping effect was observed due to cycling temperature, and the increase...

  16. Automated system for handling tritiated mixed waste

    International Nuclear Information System (INIS)

    Dennison, D.K.; Merrill, R.D.; Reitz, T.C.

    1995-03-01

    Lawrence Livermore National Laboratory (LLNL) is developing a semi system for handling, characterizing, processing, sorting, and repackaging hazardous wastes containing tritium. The system combines an IBM-developed gantry robot with a special glove box enclosure designed to protect operators and minimize the potential release of tritium to the atmosphere. All hazardous waste handling and processing will be performed remotely, using the robot in a teleoperational mode for one-of-a-kind functions and in an autonomous mode for repetitive operations. Initially, this system will be used in conjunction with a portable gas system designed to capture any gaseous-phase tritium released into the glove box. This paper presents the objectives of this development program, provides background related to LLNL's robotics and waste handling program, describes the major system components, outlines system operation, and discusses current status and plans

  17. Multi-criteria thermal evaluation of wall enclosures of high-rise buildings insulated products based on modified fibers

    Science.gov (United States)

    Pavlov, Alexey; Pavlova, Larisa; Pavlova, Lyudmila

    2018-03-01

    In article results of research of versions of offered types of heaters on the basis of products from the modified fibers for designing energy efficient building enclosures residential high-rise buildings are presented. Traditional building materials (reinforced concrete, brick, wood) are not able to provide the required value of thermal resistance in areas with a temperate and harsh Russia climate in a single-layered enclosing structure. It can be achieved in a multi-layered enclosing structure, where the decisive role is played by new insulating materials with high thermal properties. In general, modern design solutions for external walls are based on the use of new effective thermal insulation materials with the use of the latest technology. The relevance of the proposed topic is to research thermoinsulation properties of new mineral heaters. Theoretical researches of offered heaters from mineral wool on slime-colloidal binder, bentocolloid and microdispersed binders are carried out. In addition, theoretical studies were carried out with several types of facade systems. Comprehensive studies were conducted on the resistance to heat transfer, resistance to vapor permeation and air permeability. According to the received data, recommendations on the use of insulation types depending on the number of storeys of buildings are proposed.

  18. 46 CFR 169.677 - Equipment protection and enclosure.

    Science.gov (United States)

    2010-10-01

    ... Vessels of Less Than 100 Gross Tons § 169.677 Equipment protection and enclosure. (a) Except as provided... 46 Shipping 7 2010-10-01 2010-10-01 false Equipment protection and enclosure. 169.677 Section 169.677 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL...

  19. Multi agent gathering waste system

    Directory of Open Access Journals (Sweden)

    Álvaro LOZANO MURCIEGO

    2016-07-01

    Full Text Available Along this paper, we present a new multi agent-based system to gather waste on cities and villages. We have developed a low cost wireless sensor prototype to measure the volume level of the containers. Furthermore a route system is developed to optimize the routes of the trucks and a mobile application has been developed to help drivers in their working days. In order to evaluate and validate the proposed system a practical case study in a real city environment is modeled using open data available and with the purpose of identifying limitations of the system.

  20. Digital enclosure and the communication commons revival

    OpenAIRE

    Anderson, Stephen Edward

    2008-01-01

    This thesis considers the political and economic forces shaping the Internet as a medium of increasing importance in everyday life. The digital communications infrastructure is currently facing commercial enclosure on three layers: physical (regulation and ownership of the wires), content (copyright policies, media technology, ownership), and space (ownership and orientation of online tools, spaces, and services). This thesis explores and analyzes the power dynamics driving enclosure on each ...

  1. Effect of interior geometry on local climate inside an electronic device enclosure

    DEFF Research Database (Denmark)

    Joshy, Salil; Jellesen, Morten Stendahl; Ambat, Rajan

    2017-01-01

    Electronic enclosure design and the internal arrangement of PCBs and components influence microclimate inside the enclosure. This work features a general electronic unit with parallel PCBs. One of the PCB is considered to have heat generating components on it. The humidity and temperature profiles...... geometry of the device and related enclosure design parameters on the humidity and temperature profiles inside the electronic device enclosure....

  2. 30 CFR 56.12026 - Grounding transformer and switchgear enclosures.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding transformer and switchgear enclosures... MINES Electricity § 56.12026 Grounding transformer and switchgear enclosures. Metal fencing and metal buildings enclosing transformers and switchgear shall be grounded. ...

  3. Thermo-tolerant phosphate-solubilizing microbes for multi-functional biofertilizer preparation.

    Science.gov (United States)

    Chang, Cheng-Hsiung; Yang, Shang-Shyng

    2009-02-01

    In order to prepare the multi-functional biofertilizer, thermo-tolerant phosphate-solubilizing microbes including bacteria, actinomycetes, and fungi were isolated from different compost plants and biofertilizers. Except Streptomycesthermophilus J57 which lacked pectinase, all isolates possessed amylase, CMCase, chitinase, pectinase, protease, lipase, and nitrogenase activities. All isolates could solubilize calcium phosphate and Israel rock phosphate; various isolates could solubilize aluminum phosphate, iron phosphate, and hydroxyapatite. During composting, biofertilizers inoculated with the tested microbes had a significantly higher temperature, ash content, pH, total nitrogen, soluble phosphorus content, and germination rate than non-inoculated biofertilizer; total organic carbon and carbon-to-nitrogen ratio showed the opposite pattern. Adding these microbes can shorten the period of maturity, improve the quality, increase the soluble phosphorus content, and enhance the populations of phosphate-solubilizing and proteolytic microbes in biofertilizers. Therefore, inoculating thermo-tolerant phosphate-solubilizing microbes into agricultural and animal wastes represents a practical strategy for preparing multi-functional biofertilizer.

  4. Efficiency Evaluation of Food Waste Materials for the Removal of Metals and Metalloids from Complex Multi-Element Solutions

    Science.gov (United States)

    Giuliano, Antonella; Astolfi, Maria Luisa; Congedo, Rossana; Masotti, Andrea; Canepari, Silvia

    2018-01-01

    Recent studies have shown the potential of food waste materials as low cost adsorbents for the removal of heavy metals and toxic elements from wastewater. However, the adsorption experiments have been performed in heterogeneous conditions, consequently it is difficult to compare the efficiency of the individual adsorbents. In this study, the adsorption capacities of 12 food waste materials were evaluated by comparing the adsorbents’ efficiency for the removal of 23 elements from complex multi-element solutions, maintaining homogeneous experimental conditions. The examined materials resulted to be extremely efficient for the adsorption of many elements from synthetic multi-element solutions as well as from a heavy metal wastewater. The 12 adsorbent surfaces were analyzed by Fourier transform infrared spectroscopy and showed different types and amounts of functional groups, which demonstrated to act as adsorption active sites for various elements. By multivariate statistical computations of the obtained data, the 12 food waste materials were grouped in five clusters characterized by different elements’ removal efficiency which resulted to be in correlation with the specific adsorbents’ chemical structures. Banana peel, watermelon peel and grape waste resulted the least selective and the most efficient food waste materials for the removal of most of the elements. PMID:29495363

  5. Efficiency Evaluation of Food Waste Materials for the Removal of Metals and Metalloids from Complex Multi-Element Solutions.

    Science.gov (United States)

    Massimi, Lorenzo; Giuliano, Antonella; Astolfi, Maria Luisa; Congedo, Rossana; Masotti, Andrea; Canepari, Silvia

    2018-02-26

    Recent studies have shown the potential of food waste materials as low cost adsorbents for the removal of heavy metals and toxic elements from wastewater. However, the adsorption experiments have been performed in heterogeneous conditions, consequently it is difficult to compare the efficiency of the individual adsorbents. In this study, the adsorption capacities of 12 food waste materials were evaluated by comparing the adsorbents' efficiency for the removal of 23 elements from complex multi-element solutions, maintaining homogeneous experimental conditions. The examined materials resulted to be extremely efficient for the adsorption of many elements from synthetic multi-element solutions as well as from a heavy metal wastewater. The 12 adsorbent surfaces were analyzed by Fourier transform infrared spectroscopy and showed different types and amounts of functional groups, which demonstrated to act as adsorption active sites for various elements. By multivariate statistical computations of the obtained data, the 12 food waste materials were grouped in five clusters characterized by different elements' removal efficiency which resulted to be in correlation with the specific adsorbents' chemical structures. Banana peel, watermelon peel and grape waste resulted the least selective and the most efficient food waste materials for the removal of most of the elements.

  6. Efficiency Evaluation of Food Waste Materials for the Removal of Metals and Metalloids from Complex Multi-Element Solutions

    Directory of Open Access Journals (Sweden)

    Lorenzo Massimi

    2018-02-01

    Full Text Available Recent studies have shown the potential of food waste materials as low cost adsorbents for the removal of heavy metals and toxic elements from wastewater. However, the adsorption experiments have been performed in heterogeneous conditions, consequently it is difficult to compare the efficiency of the individual adsorbents. In this study, the adsorption capacities of 12 food waste materials were evaluated by comparing the adsorbents’ efficiency for the removal of 23 elements from complex multi-element solutions, maintaining homogeneous experimental conditions. The examined materials resulted to be extremely efficient for the adsorption of many elements from synthetic multi-element solutions as well as from a heavy metal wastewater. The 12 adsorbent surfaces were analyzed by Fourier transform infrared spectroscopy and showed different types and amounts of functional groups, which demonstrated to act as adsorption active sites for various elements. By multivariate statistical computations of the obtained data, the 12 food waste materials were grouped in five clusters characterized by different elements’ removal efficiency which resulted to be in correlation with the specific adsorbents’ chemical structures. Banana peel, watermelon peel and grape waste resulted the least selective and the most efficient food waste materials for the removal of most of the elements.

  7. Explosion hazards of LPG-air mixtures in vented enclosure with obstacles.

    Science.gov (United States)

    Zhang, Qi; Wang, Yaxing; Lian, Zhen

    2017-07-15

    Numerical simulations were performed to study explosion characteristics of liquefied petroleum gas (LPG) explosion in enclosure with a vent. Unlike explosion overpressure and dynamic pressure, explosion temperature of the LPG-air mixture at a given concentration in a vented enclosure has very little variation with obstacle numbers for a given blockage ratio. For an enclosure without obstacle, explosion overpressures for the stoichiometric mixtures and the fuel-lean mixtures reach their maximum within the vent and that for fuel-rich mixture reaches its maximum beyond and near the vent. Dynamic pressures produced by an indoor LPG explosion reach their maximum always beyond the vent no matter obstacles are present or not in the enclosure. A LPG explosion in a vented enclosure with built-in obstacles is strong enough to make the brick and mortar wall with a thickness of 370mm damaged. If there is no obstacle in the enclosure, the lower explosion pressure of several kPa can not break the brick and mortar wall with a thickness of 370mm. For a LPG explosion produced in an enclosure with a vent, main hazards, within the vent, are overpressure and high temperature. However main hazards are dynamic pressure, blast wind, and high temperature beyond the vent. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Multi-criteria decision analysis for waste management in Saharawi refugee camps

    International Nuclear Information System (INIS)

    Garfi, M.; Tondelli, S.; Bonoli, A.

    2009-01-01

    The aim of this paper is to compare different waste management solutions in Saharawi refugee camps (Algeria) and to test the feasibility of a decision-making method developed to be applied in particular conditions in which environmental and social aspects must be considered. It is based on multi criteria analysis, and in particular on the analytic hierarchy process (AHP), a mathematical technique for multi-criteria decision making (Saaty, T.L., 1980. The Analytic Hierarchy Process. McGraw-Hill, New York, USA; Saaty, T.L., 1990. How to Make a Decision: The Analytic Hierarchy Process. European Journal of Operational Research; Saaty, T.L., 1994. Decision Making for Leaders: The Analytic Hierarchy Process in a Complex World. RWS Publications, Pittsburgh, PA), and on participatory approach, focusing on local community's concerns. The research compares four different waste collection and management alternatives: waste collection by using three tipper trucks, disposal and burning in an open area; waste collection by using seven dumpers and disposal in a landfill; waste collection by using seven dumpers and three tipper trucks and disposal in a landfill; waste collection by using three tipper trucks and disposal in a landfill. The results show that the second and the third solutions provide better scenarios for waste management. Furthermore, the discussion of the results points out the multidisciplinarity of the approach, and the equilibrium between social, environmental and technical impacts. This is a very important aspect in a humanitarian and environmental project, confirming the appropriateness of the chosen method.

  9. Kaiser Engineers Hanford internal position paper -- Project W-236A, Multi-function Waste Tank Facility -- Peer reviews of selected activities

    International Nuclear Information System (INIS)

    Stine, M.D.

    1995-01-01

    The purpose of this paper is to develop and document a proposed position on the performance of independent peer reviews on selected design and analysis components of the Title 1 [Preliminary] and Title 2 [Final] design phases of the Multi-Function Waste Tank Facility [MWTF] project. An independent, third-party peer review is defined as a documented critical review of documents, data, designs, design inputs, tests, calculations, or related materials. The peer review should be conducted by persons independent of those who performed the work, but who are technically qualified to perform the original work. The peer review is used to assess the validity of assumptions and functional requirements, to assess the appropriateness and logic of selected methodologies and design inputs, and to verify calculations, analyses and computer software. The peer review can be conducted at the end of the design activity, at specific stages of the design process, or continuously and concurrently with the design activity. This latter method is often referred to as ''Continuous Peer Review.''

  10. Large fully retractable telescope enclosures still closable in strong wind

    Science.gov (United States)

    Bettonvil, Felix C. M.; Hammerschlag, Robert H.; Jägers, Aswin P. L.; Sliepen, Guus

    2008-07-01

    Two prototypes of fully retractable enclosures with diameters of 7 and 9 m have been built for the high-resolution solar telescopes DOT (Dutch Open Telescope) and GREGOR, both located at the Canary Islands. These enclosures protect the instruments for bad weather and are fully open when the telescopes are in operation. The telescopes and enclosures also operate in hard wind. The prototypes are based on tensioned membrane between movable but stiff bows, which fold together to a ring when opened. The height of the ring is small. The prototypes already survived several storms, with often snow and ice, without any damage, including hurricane Delta with wind speeds up to 68 m/s. The enclosures can still be closed and opened with wind speeds of 20 m/s without any problems or restrictions. The DOT successfully demonstrated the open, wind-flushing concept for astronomical telescopes. It is now widely recognized that also large future telescopes benefit from wind-flushing and retractable enclosures. These telescopes require enclosures with diameters of 30 m until roughly 100 m, the largest sizes for the ELTs (Extreme Large Telescopes), which will be built in the near future. We discuss developments and required technology for the realization of these large sizes.

  11. 30 CFR 57.12026 - Grounding transformer and switchgear enclosures.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding transformer and switchgear enclosures... NONMETAL MINES Electricity Surface and Underground § 57.12026 Grounding transformer and switchgear enclosures. Metal fencing and metal buildings enclosing transformers and switchgear shall be grounded. ...

  12. A human factors engineering evaluation of the Multi-Function Waste Tank Facility. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Donohoo, D.T. [Pacific Northwest Lab., Richland, WA (United States); Sarver, T.L. [ARES Corp., San Francisco, CA (United States)

    1995-06-05

    This report documents the methods and results of a human factors engineering (HFE) review conducted on the Multi-Function Waste Tank Facility (MWTF), Westinghouse Hanford Company (WHC) Project 236A, to be constructed at the U.S. Department of Energy (DOE) facility at Hanford, Washington. This HFE analysis of the MWTF was initiated by WHC to assess how well the current facility and equipment design satisfies the needs of its operations and maintenance staff and other potential occupants, and to identify areas of the design that could benefit from improving the human interfaces at the facility. Safe and effective operations, including maintenance, is a primary goal for the MWTF. Realization of this goal requires that the MWTF facility, equipment, and operations be designed in a manner that is consistent with the abilities and limitations of its operating personnel. As a consequence, HFE principles should be applied to the MWTF design, construction, its operating procedures, and its training. The HFE review was focused on the 200-West Area facility as the design is further along than that of the 200-East Area. The review captured, to the greatest extent feasible at this stage of design, all aspects of the facility activities and included the major topics generally associated with HFE (e.g., communication, working environment). Lessons learned from the review of the 200 West facility will be extrapolated to the 200-East Area, as well as generalized to the Hanford Site.

  13. A human factors engineering evaluation of the Multi-Function Waste Tank Facility. Final report

    International Nuclear Information System (INIS)

    Donohoo, D.T.; Sarver, T.L.

    1995-01-01

    This report documents the methods and results of a human factors engineering (HFE) review conducted on the Multi-Function Waste Tank Facility (MWTF), Westinghouse Hanford Company (WHC) Project 236A, to be constructed at the U.S. Department of Energy (DOE) facility at Hanford, Washington. This HFE analysis of the MWTF was initiated by WHC to assess how well the current facility and equipment design satisfies the needs of its operations and maintenance staff and other potential occupants, and to identify areas of the design that could benefit from improving the human interfaces at the facility. Safe and effective operations, including maintenance, is a primary goal for the MWTF. Realization of this goal requires that the MWTF facility, equipment, and operations be designed in a manner that is consistent with the abilities and limitations of its operating personnel. As a consequence, HFE principles should be applied to the MWTF design, construction, its operating procedures, and its training. The HFE review was focused on the 200-West Area facility as the design is further along than that of the 200-East Area. The review captured, to the greatest extent feasible at this stage of design, all aspects of the facility activities and included the major topics generally associated with HFE (e.g., communication, working environment). Lessons learned from the review of the 200 West facility will be extrapolated to the 200-East Area, as well as generalized to the Hanford Site

  14. A continuous exchange factor method for radiative exchange in enclosures with participating media

    International Nuclear Information System (INIS)

    Naraghi, M.H.N.; Chung, B.T.F.; Litkouhi, B.

    1987-01-01

    A continuous exchange factor method for analysis of radiative exchange in enclosures is developed. In this method two types of exchange functions are defined, direct exchange function and total exchange function. Certain integral equations relating total exchange functions to direct exchange functions are developed. These integral equations are solved using Gaussian quadrature integration method. The results obtained based on the present approach are found to be more accurate than those of the zonal method

  15. Enclosure for handling high activity materials abstract

    International Nuclear Information System (INIS)

    Jimeno de Osso, F.; Dominguez Rodriguez, G.; Cruz Castillo, F. de la; Rodriguez Esteban, A.

    1977-01-01

    One of the most important problems that are met at the laboratories producing and handling radioisotopes is that of designing, building and operating enclosures suitable for the safe handling of active substances. With that purpose in mind, an enclosure has been designed and built for handling moderately high activities under a shielding made of 150 mm thick lead. A description is given of those aspects that may be of interest to people working in this field. (author) [es

  16. Knowledge Enclosures, Forced Specializations and Investment Crisis

    Directory of Open Access Journals (Sweden)

    Filippo Belloc

    2012-12-01

    Full Text Available Like land before the industrial revolution, in the present global economy much knowledge is being enclosed in private hands. In this paper we argue that these enclosures have become a major factor in specialization among firms and among countries: both are forced to specialize in the fields that are not restricted by the enclosures of the others. We use data on 26 OECD countries over the 1978-2006 period. We estimate the effect of patents endowments of countries on their investment specialization across sectors and show that knowledge enclosures involve self-reinforcing innovation patterns. Moreover, we perform a structural change analysis and find that the TRIPs agreement has significantly strengthened the relationship between countries' patents specialization and investment specialization. We conclude by suggesting that stronger international patent protection may restrict global investment opportunities, and this may be one of the factors contributing to the present crisis.

  17. Theoretical Characterization of Enclosures

    Czech Academy of Sciences Publication Activity Database

    Rohn, Jiří

    2016-01-01

    Roč. 21, October (2016), s. 140-145 ISSN 1573-1340 Institutional support: RVO:67985807 Keywords : interval linear equations * solution set * enclosure * component * characterization Subject RIV: BA - General Mathematics http://interval.louisiana.edu/reliable-computing-journal/volume-21/reliable-computing-21-pp-140-145.pdf

  18. 40 CFR 86.1217-96 - Evaporative emission enclosure calibrations.

    Science.gov (United States)

    2010-07-01

    ... procedure: (1) Carefully measure the internal length, width and height of the enclosure, accounting for... 40 Protection of Environment 19 2010-07-01 2010-07-01 false Evaporative emission enclosure calibrations. 86.1217-96 Section 86.1217-96 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...

  19. Generic Automated Multi-function Finger Design

    Science.gov (United States)

    Honarpardaz, M.; Tarkian, M.; Sirkett, D.; Ölvander, J.; Feng, X.; Elf, J.; Sjögren, R.

    2016-11-01

    Multi-function fingers that are able to handle multiple workpieces are crucial in improvement of a robot workcell. Design automation of multi-function fingers is highly demanded by robot industries to overcome the current iterative, time consuming and complex manual design process. However, the existing approaches for the multi-function finger design automation are unable to entirely meet the robot industries’ need. This paper proposes a generic approach for design automation of multi-function fingers. The proposed approach completely automates the design process and requires no expert skill. In addition, this approach executes the design process much faster than the current manual process. To validate the approach, multi-function fingers are successfully designed for two case studies. Further, the results are discussed and benchmarked with existing approaches.

  20. Standard Guide for Selection of Test Methods for Interlayer Materials for Aerospace Transparent Enclosures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This guide summarizes the standard test methods available for determining physical and mechanical characteristics of interlayer materials used in multi-ply aerospace transparent enclosures. 1.2 Interlayer materials are used to laminate glass-to-glass, glass-to-plastic, and plastic-to-plastic. Interlayer materials are basically transparent adhesives with high-quality optical properties. They can also serve as an energy absorbing medium, a fail-safe membrane to contain cockpit pressure and to prevent entry of impact debris; a strain insulator to accommodate different thermal expansion rates of members being laminated and as an adherent to prevent spalling of inner surface ply material fragments. The relative importance of an interlayer characteristic will be a function of the prime use it serves in its particular application. 1.3 This guide, as a summary of various methods in Section 2, is intended to facilitate the selection of tests that can be applied to interlayer materials. 1.4 The test methods list...

  1. Application of glove box robotics to hazardous waste management

    International Nuclear Information System (INIS)

    Dennison, D.K.; Hurd, R.L.; Merrill, R.D.; Reitz, T.C.

    1995-02-01

    Lawrence Livermore Laboratory (LLNL) is developing a semi-automated system for handling, characterizing, processing, sorting, and repackaging hazardous wastes containing tritium. The system combines an IBM developed gantry robot with a special glove box enclosure designed to protect the operators and minimize the potential release of tritium to the atmosphere. All hazardous waste handling and processing will be performed remotely using the robot in a telerobotic mode for one-of-a-kind functions and in an autonomous mode for repetitive type operations. The system will initially be used in conjunction with a portable gas system designed to capture any gaseous phase tritium released into the glove box. This paper presents the objectives of this program, provides background related to LLNL's robotics and waste handling program, describes the major system components, outlines system operation, and discusses current status and plans

  2. Sound reduction by metamaterial-based acoustic enclosure

    Directory of Open Access Journals (Sweden)

    Shanshan Yao

    2014-12-01

    Full Text Available In many practical systems, acoustic radiation control on noise sources contained within a finite volume by an acoustic enclosure is of great importance, but difficult to be accomplished at low frequencies due to the enhanced acoustic-structure interaction. In this work, we propose to use acoustic metamaterials as the enclosure to efficiently reduce sound radiation at their negative-mass frequencies. Based on a circularly-shaped metamaterial model, sound radiation properties by either central or eccentric sources are analyzed by numerical simulations for structured metamaterials. The parametric analyses demonstrate that the barrier thickness, the cavity size, the source type, and the eccentricity of the source have a profound effect on the sound reduction. It is found that increasing the thickness of the metamaterial barrier is an efficient approach to achieve large sound reduction over the negative-mass frequencies. These results are helpful in designing highly efficient acoustic enclosures for blockage of sound in low frequencies.

  3. Sound reduction by metamaterial-based acoustic enclosure

    Energy Technology Data Exchange (ETDEWEB)

    Yao, Shanshan; Li, Pei; Zhou, Xiaoming; Hu, Gengkai, E-mail: hugeng@bit.edu.cn [Key Laboratory of Dynamics and Control of Flight Vehicle, Ministry of Education and School of Aerospace Engineering, Beijing Institute of Technology, Beijing 100081 (China)

    2014-12-15

    In many practical systems, acoustic radiation control on noise sources contained within a finite volume by an acoustic enclosure is of great importance, but difficult to be accomplished at low frequencies due to the enhanced acoustic-structure interaction. In this work, we propose to use acoustic metamaterials as the enclosure to efficiently reduce sound radiation at their negative-mass frequencies. Based on a circularly-shaped metamaterial model, sound radiation properties by either central or eccentric sources are analyzed by numerical simulations for structured metamaterials. The parametric analyses demonstrate that the barrier thickness, the cavity size, the source type, and the eccentricity of the source have a profound effect on the sound reduction. It is found that increasing the thickness of the metamaterial barrier is an efficient approach to achieve large sound reduction over the negative-mass frequencies. These results are helpful in designing highly efficient acoustic enclosures for blockage of sound in low frequencies.

  4. A Numerical Study of Fluid Flow and Heat Transfer in Carbon Dioxide Enclosures on Mars

    Directory of Open Access Journals (Sweden)

    Yue Sun

    2018-03-01

    Full Text Available In order to support the future thermal control and energy conservation design for the Mars rover, numerical studies on natural convection in CO2 enclosures on Mars’ surface were conducted for both horizontal and vertical enclosures. The parameters are as follows: the atmospheric pressure was 1000 Pa, the gravitational acceleration was 3.62 m/s2, and the Prandtl number was 0.77. The heat flux, temperature, and velocity fields of the CO2 enclosures were obtained with the aspect ratio ranging from 5.56 to 200 and the Grashof number ranging from 430 to 2.6 × 104. It was found that natural convection formed more easily in the horizontal enclosures than that in the vertical enclosures when the enclosures had same thickness. With the increasing thickness of the enclosures, Rayleigh–Bénard convections formed in the horizontal enclosures, while only single-cell convections formed in the vertical enclosures. The heat flux through the horizontal enclosures was greater than that through the vertical enclosures with the same thickness when natural convection formed. The maximum difference between them reached 35.26%, which was illustrated by the field synergy principle. A hysteresis phenomenon of the natural convection dominating the heat transfer was found in the vertical enclosure on Mars’ surface. New values for the critical Grashof number and correlations for the average Nusselt number for both the horizontal and vertical CO2 enclosures on Mars’ surface were also developed.

  5. An inexact multi-objective dynamic model and its application in China for the management of municipal solid waste

    International Nuclear Information System (INIS)

    Su, J.; Xi, B.D.; Liu, H.L.; Jiang, Y.H.; Warith, M.A.

    2008-01-01

    With the development of science and technology, solid waste management has become a serious environmental problem for most communities all over the world. This paper presents a multi-objective optimization model for the management of municipal solid waste (MSW) via an uncertainty approach. In this model, the system cost of solid waste management and the environmental impact are considered as the main objectives, and some necessary constraints based on the characteristics of China are included; additionally, Pollution loss theory is applied to evaluate the environmental impact. This model is applied to the City of Fo Shan, China. Compared with the primary project of Fo Shan, which is provided by the government, the results of the optimization procedure show that the overall system cost could be reduced by $1-2.4/ton, i.e., $3.7 million/yr. The model presented in this paper was proven to be an effective response to the multi-objective solid waste management problem, and provides a new technique to optimize MSW management and operation. Why is the optimization result better? By analyzing the modelling with respect to function, constraints, and results, we conclude that the profit would be augmented due to the amount of the waste that would be treated by recycling technology, which would increase rapidly during the planning time; thus, the total system cost could be reduced accordingly

  6. 46 CFR 154.195 - Aluminum cargo tank: Steel enclosure.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Aluminum cargo tank: Steel enclosure. 154.195 Section... Equipment Hull Structure § 154.195 Aluminum cargo tank: Steel enclosure. (a) An aluminum cargo tank and its... the aluminum cargo tank must meet the steel structural standards of the American Bureau of Shipping...

  7. Numerical Simulation of Transient Moisture Transfer into an Electronic Enclosure

    DEFF Research Database (Denmark)

    Shojaee Nasirabadi, Parizad; Jabbaribehnam, Mirmasoud; Hattel, Jesper Henri

    2016-01-01

    Electronic systems are sometimes exposed to harsh environmental conditions of temperature and humidity. Moisturetransfer into electronic enclosures and condensation can cause several problems such as corrosion and alteration in thermalstresses. It is therefore essential to study the local climate...... inside the enclosures to be able to protect the electronic systems.In this work, moisture transfer into a typical electronic enclosure is numerically studied using CFD. In order to reduce theCPU-time and make a way for subsequent factorial design analysis, a simplifying modification is applied in which...

  8. 49 CFR 193.2905 - Protective enclosures.

    Science.gov (United States)

    2010-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY LIQUEFIED NATURAL GAS FACILITIES... surrounded by a protective enclosure: (1) Storage tanks; (2) Impounding systems; (3) Vapor barriers; (4...

  9. Effects of Power Lines on Area Use and Behaviour of Semi-Domestic Reindeer in Enclosures

    International Nuclear Information System (INIS)

    Flydal, K.; Reimers, E.; Johansen, F.; Colman, J.E.; Korslund, L.; Colman, J.E.

    2009-01-01

    We conducted large-scale, replicated experiments to test the effects of two parallel power lines on area use, behaviour, and activity of semidomestic reindeer in enclosures. Yearling female reindeer were released into four 50 x 400 m enclosures; two treatment enclosures with power lines and two control enclosures. Reindeer from two herds, one from Kautokeino (domestic tame) and one from Vaga, (domestic wild) were tested separately and compared. Individual location within the enclosures was not affected by the power lines. Effects on restless behaviour were ambiguous, with slightly more restless behaviour in the treatment enclosures for the domestic tame reindeer, while the domestic wild reindeer maintained a stable level in the treatment enclosures, increasing with time in the control enclosures. Activity changes were slightly more common among animals within treatment enclosures for both herds, with no indication of habituation during the experiment. The domestic wild reindeer had more than three times the amount of restless behaviour than the domestic tame reindeer. Our study indicates that for reindeer in enclosures, the disturbance from a power line construction is negligible. This suggests that power lines are a minor disturbing factor compared to human handling when using fenced in areas like grazing gardens in reindeer husbandry.

  10. Synthesis of the IRSN report related to the containment of double walled enclosures of the operated fleet

    International Nuclear Information System (INIS)

    2013-01-01

    This report presents the IRSN's analysis on studies and modifications planned by EDF within the frame of the VD3-1300 safety re-examination which more particularly concern the third containment barrier of a reactor and of its extensions, as well as the containment of some surrounding buildings. The addressed topics are: the approach associated with the 'containment' safety function, the condition, behaviour and control of the double walled enclosure, the system of suction and filtration of the space between enclosures, the extension of the third containment barrier, the containment of building surrounding the reactor building, the risk of bypass containment, the EDF organisation with respect to the containment safety function

  11. Los Alamos transuranic waste size reduction facility

    International Nuclear Information System (INIS)

    Briesmeister, A.; Harper, J.; Reich, B.; Warren, J.L.

    1982-01-01

    To facilitate disposal of transuranic (TRU) waste, Los Alamos National Laboratory designed and constructed the Size Reduction Facility (SRF) during the period 1977 to 1981. This report summarizes the engineering development, installation, and early test operations of the SRF. The facility incorporates a large stainless steel enclosure fitted with remote handling and cutting equipment to obtain an estimated 4:1 volume reduction of gloveboxes and other bulky metallic wastes

  12. Los Alamos transuranic waste size reduction facility

    International Nuclear Information System (INIS)

    Briesmeister, A.; Harper, J.; Reich, B.; Warren, J.L.

    1982-01-01

    A transuranic (TRU) Waste Size Reduction Facility (SRF) was designed and constructed at the Los Alamos National Laboratory during the period of 1977 to 1981. This paper summarizes the engineering development, installation, and early test operations of the SRF. The facility incorporates a large stainless steel enclosure fitted with remote handling and cutting equipment to obtain an estimated 4:1 volume reduction of gloveboxes and other bulky metallic wastes

  13. A multi-criteria decision analysis assessment of waste paper management options.

    Science.gov (United States)

    Hanan, Deirdre; Burnley, Stephen; Cooke, David

    2013-03-01

    The use of Multi-criteria Decision Analysis (MCDA) was investigated in an exercise using a panel of local residents and stakeholders to assess the options for managing waste paper on the Isle of Wight. Seven recycling, recovery and disposal options were considered by the panel who evaluated each option against seven environmental, financial and social criteria. The panel preferred options where the waste was managed on the island with gasification and recycling achieving the highest scores. Exporting the waste to the English mainland for incineration or landfill proved to be the least preferred options. This research has demonstrated that MCDA is an effective way of involving community groups in waste management decision making. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Design of multi-function sensor detection system in coal mine based on ARM

    Science.gov (United States)

    Ge, Yan-Xiang; Zhang, Quan-Zhu; Deng, Yong-Hong

    2017-06-01

    The traditional coal mine sensor in the specific measurement points, the number and type of channel will be greater than or less than the number of monitoring points, resulting in a waste of resources or cannot meet the application requirements, in order to enable the sensor to adapt to the needs of different occasions and reduce the cost, a kind of multi-functional intelligent sensor multiple sensors and ARM11 the S3C6410 processor is used to design and realize the dust, gas, temperature and humidity sensor functions together, and has storage, display, voice, pictures, data query, alarm and other new functions.

  15. Multi-step process for concentrating magnetic particles in waste sludges

    Science.gov (United States)

    Watson, John L.

    1990-01-01

    This invention involves a multi-step, multi-force process for dewatering sludges which have high concentrations of magnetic particles, such as waste sludges generated during steelmaking. This series of processing steps involves (1) mixing a chemical flocculating agent with the sludge; (2) allowing the particles to aggregate under non-turbulent conditions; (3) subjecting the mixture to a magnetic field which will pull the magnetic aggregates in a selected direction, causing them to form a compacted sludge; (4) preferably, decanting the clarified liquid from the compacted sludge; and (5) using filtration to convert the compacted sludge into a cake having a very high solids content. Steps 2 and 3 should be performed simultaneously. This reduces the treatment time and increases the extent of flocculation and the effectiveness of the process. As partially formed aggregates with active flocculating groups are pulled through the mixture by the magnetic field, they will contact other particles and form larger aggregates. This process can increase the solids concentration of steelmaking sludges in an efficient and economic manner, thereby accomplishing either of two goals: (a) it can convert hazardous wastes into economic resources for recycling as furnace feed material, or (b) it can dramatically reduce the volume of waste material which must be disposed.

  16. Construction of Lightweight Loudspeaker Enclosures

    DEFF Research Database (Denmark)

    Juul-Nyholm, Herle Bagh; Severinsen, Jonas Corfitz; Schneider, Henrik

    2017-01-01

    On the basis of bass cabinets, this paper deals with the problem of reducing loudspeaker enclosure weight. An introductory market analysis emphasizes that lighter cabinets are sought, but maintenance of sound quality is vital. The problem is challenged through experiments and simulations in COMSO...

  17. Reactor enclosure. BRC meeting presentation

    International Nuclear Information System (INIS)

    Fisch, J.W.

    1975-01-01

    The latest status of key components of the Reactor Enclosure System of the Clinch River Breeder Reactor Plant is described. Areas where there have been notable design changes or significant design detail maturity in the six months since the last BRC presentation are highlighted. (auth)

  18. Multi-objective optimization of an organic Rankine cycle (ORC) for low grade waste heat recovery using evolutionary algorithm

    International Nuclear Information System (INIS)

    Wang, Jiangfeng; Yan, Zhequan; Wang, Man; Li, Maoqing; Dai, Yiping

    2013-01-01

    Highlights: • Multi-objective optimization of an ORC is conducted to obtain optimum performance. • NSGA-II is employed to solve this multi-objective optimization problem. • The effects of parameters on the exergy efficiency and capital cost are examined. - Abstract: Organic Rankine cycle (ORC) can effectively recover low grade waste heat due to its excellent thermodynamic performance. Based on the examinations of the effects of key thermodynamic parameters on the exergy efficiency and overall capital cost, multi-objective optimization of the ORC with R134a as working fluid is conducted to achieve the system optimization design from both thermodynamic and economic aspects using Non-dominated sorting genetic algorithm-II (NSGA-II). The exergy efficiency and overall capital cost are selected as two objective functions to maximize the exergy efficiency and minimize the overall capital cost under the given waste heat conditions. Turbine inlet pressure, turbine inlet temperature, pinch temperature difference, approach temperature difference and condenser temperature difference are selected as the decision variables owing to their significant effects on the exergy efficiency and overall capital cost. A Pareto frontier obtained shows that an increase in the exergy efficiency can increase the overall capital cost of the ORC system. The optimum design solution with their corresponding decision variables is selected from the Pareto frontier. The optimum exergy efficiency and overall capital cost are 13.98% and 129.28 × 10 4 USD, respectively, under the given waste heat conditions

  19. Solid Waste Program Fiscal Year 1996 Multi-Year Program Plan WBS 1.2.1, Revision 1

    International Nuclear Information System (INIS)

    1995-09-01

    This document contains the Fiscal Year 1996 Multi-Year Program Plan for the Solid Waste Program at the Hanford Reservation in Richland, Washington. The Solid Waste Program treats, stores, and disposes of a wide variety of solid wastes consisting of radioactive, nonradioactive and hazardous material types. Solid waste types are typically classified as transuranic waste, low-level radioactive waste, low-level mixed waste, and non-radioactive hazardous waste. This report describes the mission, goals and program strategies for the Solid Waste Program for fiscal year 1996 and beyond

  20. Solid Waste Program Fiscal Year 1996 Multi-Year Program Plan WBS 1.2.1, Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    This document contains the Fiscal Year 1996 Multi-Year Program Plan for the Solid Waste Program at the Hanford Reservation in Richland, Washington. The Solid Waste Program treats, stores, and disposes of a wide variety of solid wastes consisting of radioactive, nonradioactive and hazardous material types. Solid waste types are typically classified as transuranic waste, low-level radioactive waste, low-level mixed waste, and non-radioactive hazardous waste. This report describes the mission, goals and program strategies for the Solid Waste Program for fiscal year 1996 and beyond.

  1. Thermodynamic performance comparison between ORC and Kalina cycles for multi-stream waste heat recovery

    International Nuclear Information System (INIS)

    Wang, Yufei; Tang, Qikui; Wang, Mengying; Feng, Xiao

    2017-01-01

    Highlights: • Comparison between ORC and Kalina cycles (KC) for multi-stream waste heat recovery. • Divide waste heat into straight, convex and concave based on its composite curve. • Use heat ratio and temperature of the most point to show the feature of waste heat. • KC is suitable for straight and most concave heat, while ORC for convex one. - Abstract: Organic Rankine cycle (ORC) and Kalina cycle are the main technologies to recover waste heat for power generation. Up to now, many works dealing with the thermodynamic performance comparison between ORC and Kalina cycles are available, but these studies considered for heat recovery from a single heat source or stream. In the process industry, there are multiple waste heat streams, forming a complex heat source profile. In this paper, based on the simulation model developed in the Aspen Hysys software, the two cycles are calculated and compared. According to the waste heat composite curve, the multi-stream waste heat is divided into three kinds, straight, convex, and concave waste heat. Two parameters, the ratio of the heat above and below the most salient/concave point (R) and the temperature of the most point, are used to roughly express the feature of waste heat. With the efficiency from waste heat (exergy) to power as energy performance indicator, the calculation results for waste heat with maximum supply temperature 180 °C show that for straight and concave waste heat with R not less than 0.2, Kalina cycle is better than ORC, while for convex waste heat, ORC is preferable. The work can provide a reference to choose a suitable technology to recover low temperature waste heat for power generation in the process industry.

  2. Multi-criteria group decision making for evaluating the performance of e-waste recycling programs under uncertainty.

    Science.gov (United States)

    Wibowo, Santoso; Deng, Hepu

    2015-06-01

    This paper presents a multi-criteria group decision making approach for effectively evaluating the performance of e-waste recycling programs under uncertainty in an organization. Intuitionistic fuzzy numbers are used for adequately representing the subjective and imprecise assessments of the decision makers in evaluating the relative importance of evaluation criteria and the performance of individual e-waste recycling programs with respect to individual criteria in a given situation. An interactive fuzzy multi-criteria decision making algorithm is developed for facilitating consensus building in a group decision making environment to ensure that all the interest of individual decision makers have been appropriately considered in evaluating alternative e-waste recycling programs with respect to their corporate sustainability performance. The developed algorithm is then incorporated into a multi-criteria decision support system for making the overall performance evaluation process effectively and simple to use. Such a multi-criteria decision making system adequately provides organizations with a proactive mechanism for incorporating the concept of corporate sustainability into their regular planning decisions and business practices. An example is presented for demonstrating the applicability of the proposed approach in evaluating the performance of e-waste recycling programs in organizations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Manual on shielded enclosures. Incorporating: Applications guide, procedures guide, basics guide

    International Nuclear Information System (INIS)

    1992-01-01

    This booklet contains a basic guide to the principles of the production of ionizing radiation and to methods of radiation protection and dosimetry, and a discussion of the need for shielded enclosures. Shielding materials and the design of the enclosures are described

  4. GAM-HEAT -- a computer code to compute heat transfer in complex enclosures

    International Nuclear Information System (INIS)

    Cooper, R.E.; Taylor, J.R.; Kielpinski, A.L.; Steimke, J.L.

    1991-02-01

    The GAM-HEAT code was developed for heat transfer analyses associated with postulated Double Ended Guillotine Break Loss Of Coolant Accidents (DEGB LOCA) resulting in a drained reactor vessel. In these analyses the gamma radiation resulting from fission product decay constitutes the primary source of energy as a function of time. This energy is deposited into the various reactor components and is re- radiated as thermal energy. The code accounts for all radiant heat exchanges within and leaving the reactor enclosure. The SRS reactors constitute complex radiant exchange enclosures since there are many assemblies of various types within the primary enclosure and most of the assemblies themselves constitute enclosures. GAM-HEAT accounts for this complexity by processing externally generated view factors and connectivity matrices, and also accounts for convective, conductive, and advective heat exchanges. The code is applicable for many situations involving heat exchange between surfaces within a radiatively passive medium. The GAM-HEAT code has been exercised extensively for computing transient temperatures in SRS reactors with specific charges and control components. Results from these computations have been used to establish the need for and to evaluate hardware modifications designed to mitigate results of postulated accident scenarios, and to assist in the specification of safe reactor operating power limits. The code utilizes temperature dependence on material properties. The efficiency of the code has been enhanced by the use of an iterative equation solver. Verification of the code to date consists of comparisons with parallel efforts at Los Alamos National Laboratory and with similar efforts at Westinghouse Science and Technology Center in Pittsburgh, PA, and benchmarked using problems with known analytical or iterated solutions. All comparisons and tests yield results that indicate the GAM-HEAT code performs as intended

  5. Humidity Buildup in Electronic Enclosures Exposed to Constant Conditions

    DEFF Research Database (Denmark)

    Conseil, Helene; Staliulionis, Zygimantas; Jellesen, Morten Stendahl

    2017-01-01

    Electronic components and devices are exposed to a wide variety of climatic conditions, therefore the protection of electronic devices from humidity is becoming a critical factor in the system design. The ingress of moisture into typical electronic enclosures has been studied with defined paramet....... The moisture buildup inside the enclosure has been simulated using an equivalent RC circuit consisting of variables like controlled resistors and capacitors to describe the diffusivity, permeability, and storage in polymers....

  6. Multi-objective optimization of solid waste flows: environmentally sustainable strategies for municipalities.

    Science.gov (United States)

    Minciardi, Riccardo; Paolucci, Massimo; Robba, Michela; Sacile, Roberto

    2008-11-01

    An approach to sustainable municipal solid waste (MSW) management is presented, with the aim of supporting the decision on the optimal flows of solid waste sent to landfill, recycling and different types of treatment plants, whose sizes are also decision variables. This problem is modeled with a non-linear, multi-objective formulation. Specifically, four objectives to be minimized have been taken into account, which are related to economic costs, unrecycled waste, sanitary landfill disposal and environmental impact (incinerator emissions). An interactive reference point procedure has been developed to support decision making; these methods are considered appropriate for multi-objective decision problems in environmental applications. In addition, interactive methods are generally preferred by decision makers as they can be directly involved in the various steps of the decision process. Some results deriving from the application of the proposed procedure are presented. The application of the procedure is exemplified by considering the interaction with two different decision makers who are assumed to be in charge of planning the MSW system in the municipality of Genova (Italy).

  7. Oxygen ingress study of 3D printed gaseous radiation detector enclosures

    Energy Technology Data Exchange (ETDEWEB)

    Steer, Christopher A.; Durose, Aaron [AWE, Alderrnaston, Reading, Berkshire, RG7 4PR (United Kingdom)

    2015-07-01

    As part of our ongoing studies into the potential application of 3D printing techniques to gaseous radiation detectors, we have studied the ability of 3D printed enclosures to resist environmental oxygen ingress. A set of cuboid and hexagonal prism shaped enclosures with wall thicknesses of 4 mm, 6 mm, 8 mm and 10 mm were designed and printed in nylon using a EOSINT P 730 Selective Laser Sintering 3D printer system These test enclosures provide a comparison of different environmental gas ingress for different 3D printing techniques. The rate of change of oxygen concentration was found to be linear, decreasing as the wall thickness increases. It was also found that the hexagonal prism geometry produced a lower rate of change of oxygen concentration compared with the cuboid shaped enclosures. Possible reasons as to why these results were obtained are discussed The implications for the this study for deployable systems are also discussed (authors)

  8. Oxygen ingress study of 3D printed gaseous radiation detector enclosures

    International Nuclear Information System (INIS)

    Steer, Christopher A.; Durose, Aaron

    2015-01-01

    As part of our ongoing studies into the potential application of 3D printing techniques to gaseous radiation detectors, we have studied the ability of 3D printed enclosures to resist environmental oxygen ingress. A set of cuboid and hexagonal prism shaped enclosures with wall thicknesses of 4 mm, 6 mm, 8 mm and 10 mm were designed and printed in nylon using a EOSINT P 730 Selective Laser Sintering 3D printer system These test enclosures provide a comparison of different environmental gas ingress for different 3D printing techniques. The rate of change of oxygen concentration was found to be linear, decreasing as the wall thickness increases. It was also found that the hexagonal prism geometry produced a lower rate of change of oxygen concentration compared with the cuboid shaped enclosures. Possible reasons as to why these results were obtained are discussed The implications for the this study for deployable systems are also discussed (authors)

  9. A multi-criteria decision analysis assessment of waste paper management options

    Energy Technology Data Exchange (ETDEWEB)

    Hanan, Deirdre [Department of Design, Development, Environment and Materials, The Open University, Walton Hall, Milton Keynes, MK7 6AA (United Kingdom); Burnley, Stephen, E-mail: s.j.burnley@open.ac.uk [Department of Design, Development, Environment and Materials, The Open University, Walton Hall, Milton Keynes, MK7 6AA (United Kingdom); Cooke, David [Department of Design, Development, Environment and Materials, The Open University, Walton Hall, Milton Keynes, MK7 6AA (United Kingdom)

    2013-03-15

    Highlights: ► Isolated communities have particular problems in terms of waste management. ► An MCDA tool allowed a group of non-experts to evaluate waste management options. ► The group preferred local waste management solutions to export to the mainland. ► Gasification of paper was the preferred option followed by recycling. ► The group concluded that they could be involved in the decision making process. - Abstract: The use of Multi-criteria Decision Analysis (MCDA) was investigated in an exercise using a panel of local residents and stakeholders to assess the options for managing waste paper on the Isle of Wight. Seven recycling, recovery and disposal options were considered by the panel who evaluated each option against seven environmental, financial and social criteria. The panel preferred options where the waste was managed on the island with gasification and recycling achieving the highest scores. Exporting the waste to the English mainland for incineration or landfill proved to be the least preferred options. This research has demonstrated that MCDA is an effective way of involving community groups in waste management decision making.

  10. A multi-criteria decision analysis assessment of waste paper management options

    International Nuclear Information System (INIS)

    Hanan, Deirdre; Burnley, Stephen; Cooke, David

    2013-01-01

    Highlights: ► Isolated communities have particular problems in terms of waste management. ► An MCDA tool allowed a group of non-experts to evaluate waste management options. ► The group preferred local waste management solutions to export to the mainland. ► Gasification of paper was the preferred option followed by recycling. ► The group concluded that they could be involved in the decision making process. - Abstract: The use of Multi-criteria Decision Analysis (MCDA) was investigated in an exercise using a panel of local residents and stakeholders to assess the options for managing waste paper on the Isle of Wight. Seven recycling, recovery and disposal options were considered by the panel who evaluated each option against seven environmental, financial and social criteria. The panel preferred options where the waste was managed on the island with gasification and recycling achieving the highest scores. Exporting the waste to the English mainland for incineration or landfill proved to be the least preferred options. This research has demonstrated that MCDA is an effective way of involving community groups in waste management decision making

  11. 55-68 Impact of Area Enclosures on Density and Diversity of Large ...

    African Journals Online (AJOL)

    1Department of Land Resources Management and Environmental Protection, Mekelle University, ... The enclosures have higher density and diversity of large wild mammals ..... in it. Figure 4 Human interference in enclosures of the study area ...

  12. Design, construction and testing of a DC bioeffects test enclosure for small animals. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Frazier, M J; Preache, M M

    1980-11-01

    This final report describes both the engineering development of a DC bioeffects test enclosure for small laboratory animals, and the biological protocol for the use of such enclosures in the testing of animals to determine possible biological effects of the environment associated with HVDC transmission lines. The test enclosure which has been designed is a modular unit, which will house up to eight rat-sized animals in individual compartments. Multiple test enclosures can be used to test larger numbers of animals. A prototype test enclosure has been fabricated and tested to characterize its electrical performance characteristics. The test enclosure provides a simulation of the dominant environment associated with HVDC transmission lines; namely, a static electric field and an ion current density. A biological experimental design has been developed for assessing the effects of the dominant components of the HVDC transmission line environment.

  13. Multi-objective optimization of organic Rankine cycles for waste heat recovery: Application in an offshore platform

    DEFF Research Database (Denmark)

    Pierobon, Leonardo; Nguyen, Tuong-Van; Larsen, Ulrik

    2013-01-01

    This paper aims at finding the optimal design of MW-size organic Rankine cycles by employing the multi-objective optimization with the genetic algorithm as the optimizer. We consider three objective functions: thermal efficiency, total volume of the system and net present value. The optimization...... for acetone. Other promising working fluids are cyclohexane, hexane and isohexane. The present methodology can be utilized in waste heat recovery applications where a compromise between performance, compactness and economic revenue is required. © 2013 Elsevier Ltd. All rights reserved....

  14. Assessment study for multi-barrier system used in radioactive borate waste isolation based on Monte Carlo simulations.

    Science.gov (United States)

    Bayoumi, T A; Reda, S M; Saleh, H M

    2012-01-01

    Radioactive waste generated from the nuclear applications should be properly isolated by a suitable containment system such as, multi-barrier container. The present study aims to evaluate the isolation capacity of a new multi-barrier container made from cement and clay and including borate waste materials. These wastes were spiked by (137)Cs and (60)Co radionuclides to simulate that waste generated from the primary cooling circuit of pressurized water reactors. Leaching of both radionuclides in ground water was followed and calculated during ten years. Monte Carlo (MCNP5) simulations computed the photon flux distribution of the multi-barrier container, including radioactive borate waste of specific activity 11.22KBq/g and 4.18KBq/g for (137)Cs and (60)Co, respectively, at different periods of 0, 15.1, 30.2 and 302 years. The average total flux for 100cm radius of spherical cell was 0.192photon/cm(2) at initial time and 2.73×10(-4)photon/cm(2) after 302 years. Maximum waste activity keeping the surface radiation dose within the permissible level was calculated and found to be 56KBq/g with attenuation factors of 0.73cm(-1) and 0.6cm(-1) for cement and clay, respectively. The average total flux was 1.37×10(-3)photon/cm(2) after 302 years. Monte Carlo simulations revealed that the proposed multi-barrier container is safe enough during transportation, evacuation or rearrangement in the disposal site for more than 300 years. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Multi criteria decision analysis on a waste repository in Mol

    International Nuclear Information System (INIS)

    Carle, B.

    2005-01-01

    In Belgium, the management of radioactive waste is taken care of by ONDRAF/NIRAS, the Belgian Agency for Radioactive Waste and Enriched Fissile Materials. Local partnerships with stakeholders from municipalities in existing nuclear zones were setup to facilitate the dialogue between the repository designers and the local community. Since the establishment of the partnership in Mol, MONA in February 2000, all aspects of a possible near-surface or a deep geological repository are discussed in 4 working groups by around 50 volunteer members. The outcome of the discussions in the partnership can be a shared project, supported by both local stakeholders and ONDRAF/NIRAS, in which the specifications and the conditions needed for establishing a repository in Mol are elaborated. MONA asked the Decision Strategy Research Department of SCK-CEN to organise a Multi Criteria Analysis (MCA) in the context of the deciding between a surface and a deep repository for low level radioactive waste. The objective of the multi criteria analysis is to support a number of representatives of the various working groups within MONA in their selection between two acceptable options for a repository of low level radioactive waste on the territory of Mol. The options are the surface repository developed by the working groups of MONA, and a deep repository in the clay layers underneath the nuclear site of Mol. This study should facilitate the selection between both options, or in case this appears to be difficult, at least to get a well-structured overview of all factors (criteria) of importance to the judgement, and to get insight into the degree in which the various criteria contribute to the selection

  16. The Effects of Spatial Enclosure on Social Interaction Between Older Adults With Dementia and Young Children.

    Science.gov (United States)

    Cerruti, Minyoung S; Shepley, Mardelle M

    2016-04-01

    To examine the impact of spatial enclosures on social interaction between older adults with early stage dementia and young children. Intergenerational interaction through meaningful activities can promote positive affects and behaviors of children and older adults. The development of social interaction is closely related to the physical environment in association with personal competence of older adults with dementia and young children. However, minimal attention has been given to the role of physical environment in influencing intergenerational interaction. A quasi-experiment examined the functional relationship between the amount of spatial enclosure and the types of social behaviors of older adults with dementia and young children. Semi-structured interviews, aided by a photographic simulation, were developed to explore the participants' perceptions of and experiences with the different degrees of spatial enclosure. Findings showed that the semienclosed spatial plan impacted both prosocial and antisocial behaviors of older adults with dementia in their interactions with young children. This apparent discrepancy was associated with two conflicting perceptions: a sense of openness and the lack of control due to distraction created by the loose visual boundary. There was no correlation between the elder-child neutral behaviors and the degrees of spatial enclosure. This study suggests that spaces with moderate openness without visual and acoustic distraction are the most desirable to promote prosocial behaviors of older adults with dementia and young children. Additionally, elder-child prosocial behaviors were likely facilitated by specific design features such as adequate personal space, the perception of openness, and possible spaces that provide both prospect and refuge in relation to spatial enclosure. © The Author(s) 2016.

  17. A Multi-Criteria Decision Analysis of Waste Treatment Options for Food and Biodegradable Waste Management in Japan

    Directory of Open Access Journals (Sweden)

    Micky A. Babalola

    2015-10-01

    Full Text Available Dealing with large-scale Food and Biodegradable Waste (FBW often results in many logistical problems and environmental impacts to be considered. These can become great hindrances when the integration of solid waste management is concerned. Extra care is needed to plan such waste disposal or treatment services and facilities, especially with respect to the ecological impact. Decision-making with regards to the sustainable use of these facilities also involves tradeoffs between a number of conflicting objectives, since increasing one benefit may decrease the others. In this study a Multi-Criteria Decision Analysis (MCDA is presented to evaluate different waste management options and their applicability in Japan. The analytical process aims at selecting the most suitable waste treatment option, using pairwise comparisons conducted within a decision hierarchy that was developed through the Analytical Hierarchy Process (AHP. The results of this study show that anaerobic digestion should be chosen as the best FBW treatment option with regards to resource recovery. The study also presents some conditions and recommendations that can enhance the suitability of other options like incineration and composting.

  18. Investigations into the dynamics of aerosols in enclosures as used for air pollution studies

    International Nuclear Information System (INIS)

    Vate, J.F. van de.

    1980-07-01

    The author treats aerosol behaviour under various conditions in enclosed spaces. A model is given describing aerosol removal from enclosed spaces; boundary conditions are given for non-stirred deposition of aerosols by sedimentation and diffusion. Experimental results are presented for unheated dry enclosures, heated dry enclosures, enclosures with a heated pool of liquid, and smog chambers. (G.T.H.)

  19. Enclosure design for flock-level, chronic exposure of birds to air contaminant mixtures.

    Science.gov (United States)

    North, Michelle A; Kinniburgh, David W; Smits, Judit E G

    2018-05-01

    The objective of this study was to design an enclosure suitable for studying the ecotoxicological effects of vehicle emissions on groups of wild birds without compromising welfare. Two, adjacent enclosures sheltered from sunlight, wind and rain, were bird-proofed and wrapped with thick polyethylene sheeting. Emissions were directed into the treatment enclosure from the exhaust of a light-duty gasoline truck, using flexible, heat-proof pipe, with joins sealed to prevent leakage. During active exposure, the engine was idled for 5 h/day, 6 days/week for 4 weeks. Fans maintained positive pressure (controls) and negative pressure (treatment), preventing cross-contamination of enclosures and protecting investigators. Four sets of passive, badge-type samplers were distributed across each enclosure, measuring nitrogen dioxide, sulfur dioxide and volatile organic compounds (NO 2 , SO 2 and VOCs, respectively), and were complemented by active monitors measuring VOCs and particulate matter (2.5 µm diameter, PM 2.5 ). We found that the concentrations of NO 2 , SO 2 and PM 2.5 were not different between treatment and control enclosures. Volatile organic compounds (e.g. benzene, toluene, ethylbenzene and xylenes) were approximately six times higher in the treatment enclosure than control (13.23 and 2.13 µg m -1 , respectively). In conclusion, this represents a successful, practical design for studying the effects of sub-chronic to chronic exposure to realistic mixtures of vehicle exhaust contaminants, in groups of birds. Recommended modifications for future research include a chassis dynamometer (vehicle treadmill), to better replicate driving conditions including acceleration and deceleration.

  20. Fuel optimization in a multi chamber incinerator by the moisture control of oily sludge and medical wastes

    International Nuclear Information System (INIS)

    Haider, I.; Hussain, S.; Khan, S.; Mehran, T.

    2011-01-01

    Experiments have been performed to study the effects of %age moisture content on fuel optimization during the waste feed combustion of oily sludge, medical waste and mix blend waste in a 50 kg/hr multi chamber incinerator installed at NCPC- ARL RWP. Intention is to find out the optimum and in compliance with NEQs incinerator performance at various moisture contents in the different waste feeds. Optimum performances of the incinerator, so that optimum operating moisture conditions, which has been used for multi purpose waste, feeds, may be defined. Three waste feeds of 10 kg batch size were used for the experimentation namely; Oily Sludge, Medical waste and Mix blend waste (oily sludge and medical), with the primary chamber preheating temperature 655 deg. C for 15 mins. interval monitoring. The secondary chamber temperature was set to 850 deg. C. By the data obtained it is apparent that rising the waste moisture content tend to increase fuel consumption specifically in case of medical waste and hence lowering the overall combustion efficiency. In the emissions the CO/sub 2/ concentration is showing the incineration efficiency. Higher efficiency of the system could have been achieved by increasing the CO/sub 2/ in the gases leaving the incinerator, lower fuel usage per kg waste feed and maintain proper operating conditions. Fuel consumption for the oily sludge with 10% moisture content, was found to be least as compared with the same %age of medical waste and mix blend waste. However environmental compliance of the operation is shown by the flue gas analysis. The results shows that using mix blend(oily sludge and medical) waste having 12-13% moisture content would be suitable for incineration in multi-chamber incinerator .Other makes it possible to determine the optimum incinerator temperature control settings and operating conditions, as well as to assure continuous, efficient, environmentally satisfactory operation. The optimum fuel consumption for 10 kg each waste

  1. Numerical modeling of buoyancy-driven turbulent flows in enclosures

    International Nuclear Information System (INIS)

    Hsieh, K.J.; Lien, F.S.

    2004-01-01

    Modeling turbulent natural convection in enclosures with differentially heated vertical walls is numerically challenging, in particular, when low-Reynolds-number (low-Re) models are adopted. When the turbulence level in the core region of cavity is low, most low-Re models, particular those showing good performance for bypass transitional flows, tend to relaminarize the flow and, as a consequence, significantly underpredict the near-wall turbulence intensities and boundary-layer thickness. Another challenge associated with low-turbulence buoyancy-driven flows in enclosures is its inherent unsteadiness, which can pose convergence problems when a steady Reynolds-averaged Navier-Stokes (RANS) equation is solved. In the present study, an unsteady RANS approach in conjunction with the low-Re k-ε model of Lien and Leschziner [Int. J. Comput. Fluid Dyn. 12 (1999) 1] is initially adopted and the predicted flow field is found effectively relaminarized. To overcome this difficulty, likely caused by the low-Re functions in the ε-equation, the two-layer approach is attempted, in which ε is prescribed algebraically using the one-equation k-l model of Wolfshtein [Int. J. Heat Mass Transfer 12 (1969) 301]. The two-layer approach combined with a quadratic stress-strain relation gives overall the best performance in terms of mean velocities, temperature and turbulence quantities

  2. 50 CFR 14.161 - Primary enclosures.

    Science.gov (United States)

    2010-10-01

    ... Wild Mammals and Birds to the United States Specifications for Other Terrestrial Mammals § 14.161... primary enclosure shall provide adequate space for the animal to stand upright in a normal posture with... lie in a full prone position. Specifications for Birds ...

  3. Aerothermodynamic properties of stretched flames in enclosures

    Science.gov (United States)

    Rotman, D. A.; Oppenheim, A. K.

    Flames are stretched by being pulled along their frontal surface by the flow field in which they reside. Their trajectories tend to approach particle paths, acquiring eventually the role of contact boundaries, -interfaces between the burnt and unburnt medium that may broaden solely as a consequence of diffusion. Fundamental properties of flow fields governing such flames are determined here on the basis of the zero Mach number model, providng a rational method of approach to the computational analysis of combustion fields in enclosures where, besides the aerodynamic properties flow, the thermodynamic process of compression must be taken into account. To illustrate its application, the method is used to reveal the mechanism of formation of a tulip-shape flame in a rectangular enclosure under nonturbulent flow conditions.

  4. 9 CFR 3.6 - Primary enclosures.

    Science.gov (United States)

    2010-01-01

    ... coated with a material such as plastic or fiberglass. The suspended floor of any primary enclosure must... and behavioral characteristics, and in accordance with generally accepted husbandry practices. If the... characteristics, and in accordance with generally accepted husbandry practices as determined by the attending...

  5. Numerical simulation of transient moisture transfer into an electronic enclosure

    Energy Technology Data Exchange (ETDEWEB)

    Nasirabadi, P. Shojaee; Jabbari, M.; Hattel, J. H. [Process Modelling Group, Department of Mechanical Engineering, Technical University of Denmark, Nils Koppels Allé, 2800 Kgs. Lyngby (Denmark)

    2016-06-08

    Electronic systems are sometimes exposed to harsh environmental conditions of temperature and humidity. Moisture transfer into electronic enclosures and condensation can cause several problems such as corrosion and alteration in thermal stresses. It is therefore essential to study the local climate inside the enclosures to be able to protect the electronic systems. In this work, moisture transfer into a typical electronic enclosure is numerically studied using CFD. In order to reduce the CPU-time and make a way for subsequent factorial design analysis, a simplifying modification is applied in which the real 3D geometry is approximated by a 2D axial symmetry one. The results for 2D and 3D models were compared in order to calibrate the 2D representation. Furthermore, simulation results were compared with experimental data and good agreement was found.

  6. Numerical simulation of transient moisture transfer into an electronic enclosure

    International Nuclear Information System (INIS)

    Nasirabadi, P. Shojaee; Jabbari, M.; Hattel, J. H.

    2016-01-01

    Electronic systems are sometimes exposed to harsh environmental conditions of temperature and humidity. Moisture transfer into electronic enclosures and condensation can cause several problems such as corrosion and alteration in thermal stresses. It is therefore essential to study the local climate inside the enclosures to be able to protect the electronic systems. In this work, moisture transfer into a typical electronic enclosure is numerically studied using CFD. In order to reduce the CPU-time and make a way for subsequent factorial design analysis, a simplifying modification is applied in which the real 3D geometry is approximated by a 2D axial symmetry one. The results for 2D and 3D models were compared in order to calibrate the 2D representation. Furthermore, simulation results were compared with experimental data and good agreement was found.

  7. Laying hen movement in a commercial aviary: Enclosure to floor and back again.

    Science.gov (United States)

    Campbell, D L M; Makagon, M M; Swanson, J C; Siegford, J M

    2016-01-01

    Many producers in the laying hen industry, including in North America, are phasing out conventional cages in response to consumer demands and sometimes subsequent legislation. Alternative housing systems such as aviaries are being implemented in an attempt to improve hen welfare. Aviaries provide additional space and resources to groups of hens, including a litter area on the floor. However, little is known about hen movement between tiered enclosures and floor litter areas in aviary systems. Diurnal rhythms and social attraction may result in peak times of movement that could lead to overcrowding of areas, or alternatively hen preferences may lead to some areas not being fully utilized. We monitored hen movement between tiered enclosures and litter areas, including movement on and off the outer perch, across the day at peak, mid and end of lay in a commercial aviary. Hens moved onto and off of the open litter area across the day, transitioning between tiered enclosures, outer perches, open litter areas, and litter areas under tiered enclosures. At certain times of day, there were periods of greater hen movement down to the open litter area and between litter areas. For example, more hens were typically observed exiting enclosures, jumping from perches to open litter, and traveling between open litter and litter under tiered enclosures in the morning (all P ≤ 0.001). In all but one instance, more hens were observed on open litter areas in the afternoon than at other times of day (all P ≤ 0.029). However, hen re-entry to tiered enclosures showed less circadian patterning. Hen movement was observed between areas of interest at all sampled time periods, indicating hens use all areas of the system. Further research should examine whether all individual hens do move between areas equally, including within levels of the tiered enclosure, or if crowding occurs on the outer perches or in the litter during times of peak movement. © 2015 Poultry Science Association Inc.

  8. Apparatus for posting materials into and out of enclosures

    International Nuclear Information System (INIS)

    Sperinck, W.A.; Ashcroft, K.C.

    1986-01-01

    The patent concerns an apparatus for posting toxic or radioactive materials into and out of a high integrity enclosure, such as a glovebox, through a port in a wall of the enclosure. The apparatus comprises a container for the materials, with a lid which is engageable with a door for the port, and the container is supported in a cradle. The door cannot be opened in the absence of a container in the cradle, and the container cannot be removed when the door and lid unit is away from the port. (UK)

  9. Minimization of actinide waste by multi-recycling of thoriated fuels in the EPR reactor

    Directory of Open Access Journals (Sweden)

    Nuttin A.

    2012-02-01

    Full Text Available The multi-recycling of innovative uranium/thorium oxide fuels for use in the European Pressurized water Reactor (EPR has been investigated. If increasing quantities of 238U, the fertile isotope in standard UO2 fuel, are replaced by 232Th, then a greater yield of new fissile material (233U is produced during the cycle than would otherwise be the case. This leads to economies of natural uranium of around 45% if the uranium in the spent fuel is multi-recycled. In addition we show that minor actinide and plutonium waste inventories are reduced and hence waste radio-toxicities and decay heats are up to a factor of 20 lower after 103 years. Two innovative fuel types named S90 and S20, ThO2 mixed with 90% and 20% enriched UO2 respectively, are compared as an alternative to standard uranium oxide (UOX and uranium/plutonium mixed oxide (MOX fuels at the longest EPR fuel discharge burn-ups of 65 GWd/t. Fissile and waste inventories are examined, waste radio-toxicities and decay heats are extracted and safety feedback coefficients are calculated.

  10. 50 CFR 14.151 - Primary enclosures.

    Science.gov (United States)

    2010-10-01

    ... Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR TAKING... Wild Mammals and Birds to the United States Specifications for Sloths, Bats, and Flying Lemurs... located on the upper one-half of the primary enclosure. (b) No more than one sloth, bat, or flying lemur...

  11. Radiant cooling of an enclosure

    International Nuclear Information System (INIS)

    Chebihi, Abdeslam; Byun, Ki-Hong; Wen Jin; Smith, Theodore F.

    2006-01-01

    The purpose of this study is to analyze the potential for radiant cooling using the atmospheric sky window and to evaluate the desired characteristics of a radiant cooling material (RCM) applied to the ceiling window of a three-dimensional enclosure. The thermal characteristics of the system are governed by the geometry, ambient temperature, sky radiative temperature, amount of solar energy and its direction, heat transfer modes, wall radiative properties, and radiative properties of the RCMs. A semi-gray band analysis is utilized for the solar and infrared bands. The radiosity/irradiation method is used in each band to evaluate the radiant exchanges in the enclosure. The radiative properties for the RCM are varied in a parametric study to identify the desired properties of RCMs. For performance simulation of real RCMs, the radiative properties are calculated from spectral data. The desired solar property is a high reflectance for both opaque and semi-transparent RCMs. For a semi-transparent RCM, a low value of the solar transmittance is preferred. The desired infrared property is a high emittance for an opaque RCM. For a semi-transparent RCM, a high infrared transmittance is desired, and the emittance should be greater than zero

  12. ZFS on RBODs - Leveraging RAID Controllers for Metrics and Enclosure Management

    Energy Technology Data Exchange (ETDEWEB)

    Stearman, D. M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-03-30

    Traditionally, the Lustre file system has relied on the ldiskfs file system with reliable RAID (Redundant Array of Independent Disks) storage underneath. As of Lustre 2.4, ZFS was added as a backend file system, with built-in software RAID, thereby removing the need of expensive RAID controllers. ZFS was designed to work with JBOD (Just a Bunch Of Disks) storage enclosures under the Solaris Operating System, which provided a rich device management system. Long time users of the Lustre file system have relied on the RAID controllers to provide metrics and enclosure monitoring and management services, with rich APIs and command line interfaces. This paper will study a hybrid approach using an advanced full featured RAID enclosure which is presented to the host as a JBOD, This RBOD (RAIDed Bunch Of Disks) allows ZFS to do the RAID protection and error correction, while the RAID controller handles management of the disks and monitors the enclosure. It was hoped that the value of the RAID controller features would offset the additional cost, and that performance would not suffer in this mode. The test results revealed that the hybrid RBOD approach did suffer reduced performance.

  13. ZFS on RBODs - Leveraging RAID Controllers for Metrics and Enclosure Management

    International Nuclear Information System (INIS)

    Stearman, D. M.

    2015-01-01

    Traditionally, the Lustre file system has relied on the ldiskfs file system with reliable RAID (Redundant Array of Independent Disks) storage underneath. As of Lustre 2.4, ZFS was added as a backend file system, with built-in software RAID, thereby removing the need of expensive RAID controllers. ZFS was designed to work with JBOD (Just a Bunch Of Disks) storage enclosures under the Solaris Operating System, which provided a rich device management system. Long time users of the Lustre file system have relied on the RAID controllers to provide metrics and enclosure monitoring and management services, with rich APIs and command line interfaces. This paper will study a hybrid approach using an advanced full featured RAID enclosure which is presented to the host as a JBOD, This RBOD (RAIDed Bunch Of Disks) allows ZFS to do the RAID protection and error correction, while the RAID controller handles management of the disks and monitors the enclosure. It was hoped that the value of the RAID controller features would offset the additional cost, and that performance would not suffer in this mode. The test results revealed that the hybrid RBOD approach did suffer reduced performance.

  14. Clearance of radioactive materials during reactor dismantling. Permanent enclosure instead of demolition and renaturation?; Freigabe radioaktiven Materials beim AKW-Abriss. Dauerhafter Einschluss statt Rueckbau?

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-07-01

    During reactor dismantling besides high-level radioactive wastes a large amount of low-level contaminated steel and concrete has to be disposed. In case that radioactivity falls below defined dose limits (10 micro Sv/person and year) these materials may be disposed in domestic waste landfill or in municipal incineration facilities. The issue is discussed in detail including the fact that many power plants are dismantled at the same time so that the contaminated materials might accumulate. Another issue is the occupational safety of contract workers during dismantling. The permanent enclosure could avoid this environmental contamination of decommissioned power plants might also be less expensive.

  15. Impact resistant battery enclosure systems

    Science.gov (United States)

    Tsutsui, Waterloo; Feng, Yuezhong; Chen, Weinong Wayne; Siegmund, Thomas Heinrich

    2017-10-31

    Battery enclosure arrangements for a vehicular battery system. The arrangements, capable of impact resistance include plurality of battery cells and a plurality of kinetic energy absorbing elements. The arrangements further include a frame configured to encase the plurality of the kinetic energy absorbing elements and the battery cells. In some arrangements the frame and/or the kinetic energy absorbing elements can be made of topologically interlocked materials.

  16. Analysis of sound absorption performance of an electroacoustic absorber using a vented enclosure

    Science.gov (United States)

    Cho, Youngeun; Wang, Semyung; Hyun, Jaeyub; Oh, Seungjae; Goo, Seongyeol

    2018-03-01

    The sound absorption performance of an electroacoustic absorber (EA) is primarily influenced by the dynamic characteristics of the loudspeaker that acts as the actuator of the EA system. Therefore, the sound absorption performance of the EA is maximum at the resonance frequency of the loudspeaker and tends to degrade in the low-frequency and high-frequency bands based on this resonance frequency. In this study, to adjust the sound absorption performance of the EA system in the low-frequency band of approximately 20-80 Hz, an EA system using a vented enclosure that has previously been used to enhance the radiating sound pressure of a loudspeaker in the low-frequency band, is proposed. To verify the usefulness of the proposed system, two acoustic environments are considered. In the first acoustic environment, the vent of the vented enclosure is connected to an external sound field that is distinct from the sound field coupled to the EA. In this case, the acoustic effect of the vented enclosure on the performance of the EA is analyzed through an analytical approach using dynamic equations and an impedance-based equivalent circuit. Then, it is verified through numerical and experimental approaches. Next, in the second acoustic environment, the vent is connected to the same external sound field as the EA. In this case, the effect of the vented enclosure on the EA is investigated through an analytical approach and finally verified through a numerical approach. As a result, it is confirmed that the characteristics of the sound absorption performances of the proposed EA system using the vented enclosure in the two acoustic environments considered in this study are different from each other in the low-frequency band of approximately 20-80 Hz. Furthermore, several case studies on the change tendency of the performance of the EA using the vented enclosure according to the critical design factors or vent number for the vented enclosure are also investigated. In the future

  17. 9 CFR 3.53 - Primary enclosures.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Primary enclosures. 3.53 Section 3.53 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE ANIMAL... maintained in good repair to protect the rabbits from injury, to contain them, and to keep predators out. (2...

  18. Standard Guide for Testing Materials for Aerospace Plastic Transparent Enclosures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This guide is intended to summarize the standard test methods available on individual and composite materials utilized in fabrication of aerospace plastic transparent enclosures. As such, it is intended to specifically include transparent thermoplastics, transparent elastomers, and reinforced plastics, whether thermoplastic or thermosetting. 1.2 This guide is intended as an aid in the search for test methods pertinent to Aerospace Plastic Transparent Enclosures. It should be understood that all methods listed may not apply to all enclosures. 1.3 The standards included refer to the properties or aspects listed in Table 1. The properties or aspects are listed in alphabetical order and the descriptions used are intended to facilitate the search. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limi...

  19. Tank Waste Remediation System fiscal year 1996 multi-year program plan WBS 1.1. Revision 1, Appendix A

    International Nuclear Information System (INIS)

    1995-09-01

    This document is a compilation of data relating to the Tank Waste Remediation System Multi-Year Program. Topics discussed include: management systems; waste volume, transfer and evaporation management; transition of 200 East and West areas; ferricyanide, volatile organic vapor, and flammable gas management; waste characterization; retrieval from SSTs and DSTs; heat management; interim storage; low-level and high-level radioactive waste management; and tank farm closure

  20. Enclosure environment characterization testing for the base line validation of computer fire simulation codes

    International Nuclear Information System (INIS)

    Nowlen, S.P.

    1987-03-01

    This report describes a series of fire tests conducted under the direction of Sandia National Laboratories for the US Nuclear Regulatory Commission. The primary purpose of these tests was to provide data against which to validate computer fire environment simulation models to be used in the analysis of nuclear power plant enclosure fire situations. Examples of the data gathered during three of the tests are presented, though the primary objective of this report is to provide a timely description of the test effort itself. These tests were conducted in an enclosure measuring 60x40x20 feet constructed at the Factory Mutual Research Corporation fires test facility in Rhode Island. All of the tests utilized forced ventilation conditions. The ventilation system was designed to simulate typical nuclear power plant installation practices and ventilation rates. A total of 22 tests using simple gas burner, heptane pool, methanol pool, and PMMA solid fires was conducted. Four of these tests were conducted with a full-scale control room mockup in place. Parameters varied during testing were fire intensity, enclosure ventilation rate, and fire location. Data gathered include air temperatures, air velocities, radiative and convective heat flux levels, optical smoke densities, inner and outer enclosure surface temperatures, enclosure surface heat flux levels, and gas concentrations within the enclosure in the exhaust stream

  1. Effect of Darcy, fluid Rayleigh and heat generation parameters on natural convection in a porous square enclosure: A Brinkman-extended Darcy model

    International Nuclear Information System (INIS)

    Das, S.; Sahoo, R.K.

    1999-01-01

    Analysis of flow and convective heat transfer in volumetrically heated porous layer has become a separate topic for research in the last twenty five years in view of its importance in various engineering applications, such as heat removal from nuclear fuel debris, heat transfer associated with storage of nuclear waste, exothermic reaction in packed-bed reactors, heat recovery from geothermal systems and particularly in the field of large storage systems of agricultural products. Here, a pressure-velocity solution for natural convection for fluid saturated heat generating porous medium in a square enclosure is analyzed by finite element method. The numerical solutions obtained for wide range of fluid Rayleigh number, Ra f , Darcy number, Da, and heat generating number, Q d . The justification for taking these non-dimensional parameters independently is to establish the effect of individual parameters on flow patterns. It has been observed that peak temperature occurs at the top central part and weaker velocity prevails near the vertical walls of the enclosure due to the heat generation parameter alone. On comparison, the modified Rayleigh number used by the earlier investigators, can not explain explicitly the effect of heat generation parameter on natural convection within an enclosure having differentially heated vertical walls. At higher Darcy number, the peak temperature and peak velocity are comparatively more, resulting in better enhancement of heat transfer rate

  2. Cold Climate Building Enclosure Solutions

    Energy Technology Data Exchange (ETDEWEB)

    Kosny, Jan [Fraunhofer CSE, Cambridge, MA (United States); Fallahi, Ali [Fraunhofer CSE, Cambridge, MA (United States); Shukla, Nitin [Fraunhofer CSE, Cambridge, MA (United States)

    2013-01-01

    This project investigates the energy performance and cost effectiveness of several state-of-the-art retrofit strategies that could be used in triple-deckers and colonial houses, common house types in New England. Several emerging building enclosure technologies were integrated, including high R-value aerogel and vacuum insulations, in forms that would be energy efficient, flexible for different retrofit scenarios, durable, and potentially cost-competitive for deep energy retrofits.

  3. Semi-empirical prediction of moisture build-up in an electronic enclosure using analysis of variance (ANOVA)

    DEFF Research Database (Denmark)

    Shojaee Nasirabadi, Parizad; Conseil, Helene; Mohanty, Sankhya

    2016-01-01

    Electronic systems are exposed to harsh environmental conditions such as high humidity in many applications. Moisture transfer into electronic enclosures and condensation can cause several problems as material degradation and corrosion. Therefore, it is important to control the moisture content...... and the relative humidity inside electronic enclosures. In this work, moisture transfer into a typical polycarbonate electronic enclosure with a cylindrical shape opening is studied. The effects of four influential parameters namely, initial relative humidity inside the enclosure, radius and length of the opening...... and temperature are studied. A set of experiments are done based on a fractional factorial design in order to estimate the time constant for moisture transfer into the enclosure by fitting the experimental data to an analytical quasi-steady-state model. According to the statistical analysis, temperature...

  4. Electric devices used in radioactive handling enclosures of the high activity laboratory

    International Nuclear Information System (INIS)

    Gaigeot, F.; Laurent, H.

    1958-08-01

    This report describes several electric, electronic and electromechanical assemblies which are used in radioactive handling enclosures. The authors propose an overview of existing or foreseen devices: a device to lift covers, a brightness comparator, a high voltage device to perform electrophoresis, a level sensor or regulator device, a regulation device to control under-pressure in an enclosure [fr

  5. Mixing processes in high-level waste tanks. 1998 annual progress report

    International Nuclear Information System (INIS)

    Peterson, P.F.

    1998-01-01

    Flammable gases can be generated in DOE high-level waste tanks, including radiolytic hydrogen, and during cesium precipitation from salt solutions, benzene. Under normal operating conditions the potential for deflagration or detonation from these gases is precluded by purging and ventilation systems, which remove the flammable gases and maintain a well-mixed condition in the tanks. Upon failure of the ventilation system, due to seismic or other events, however, it has proven more difficult to make strong arguments for well-mixed conditions, due to the potential for density-induced stratification which can potentially sequester fuel or oxidizer at concentrations significantly higher than average. This has complicated the task of defining the safety basis for tank operation. Waste-tank mixing processes have considerable overlap with similar large-enclosure mixing processes that occur in enclosure fires and nuclear reactor containments. Significant differences also exist, so that modeling techniques that have been developed previously can not be directly applied to waste tanks. In particular, mixing of air introduced through tank roof penetrations by buoyancy and pressure driven exchange flows, mixed convection induced by an injected high-velocity purge jet interacting with buoyancy driven flow, and onset and breakdown of stable stratification under the influence of an injected jet have not been adequately studied but are important in assessing the potential for accumulation of high-concentration pockets of fuel and oxygen. Treating these phenomena requires a combination of experiments and the development of new, more general computational models than those that have been developed for enclosure fires. U.C. Berkeley is now completing the second year of its three-year project that started in September, 1996. Excellent progress has been made in several important areas related to waste-tank ventilation and mixing processes.'

  6. Optimal External-Memory Planar Point Enclosure

    DEFF Research Database (Denmark)

    Arge, Lars; Samoladas, Vasilis; Yi, Ke

    2007-01-01

    .g. spatial and temporal databases, and is dual to the important and well-studied orthogonal range searching problem. Surprisingly, despite the fact that the problem can be solved optimally in internal memory with linear space and O(log N+K) query time, we show that one cannot construct a linear sized......In this paper we study the external memory planar point enclosure problem: Given N axis-parallel rectangles in the plane, construct a data structure on disk (an index) such that all K rectangles containing a query point can be reported I/O-efficiently. This problem has important applications in e...... external memory point enclosure data structure that can be used to answer a query in O(log  B N+K/B) I/Os, where B is the disk block size. To obtain this bound, Ω(N/B 1−ε ) disk blocks are needed for some constant ε>0. With linear space, the best obtainable query bound is O(log 2 N+K/B) if a linear output...

  7. Multi-Function Waste Tank Facility phase out basis. Revision 2

    International Nuclear Information System (INIS)

    Awadalla, N.G.

    1995-01-01

    Additional double-shell tank storage capacity is not needed until FY 2004 or later. The waste volume in the current baseline program can be managed within the existing tank capacity. However, this requires implementation of some risk management actions and significant investment in software and hardware to accomplish the actions necessary to maximize use of existing storage tank space

  8. Multi-Function Waste Tank Facility phase out basis. Revision 1

    International Nuclear Information System (INIS)

    Awadalla, N.G.

    1995-01-01

    Additional double-shell tank storage capacity is not needed until FY 2004 or later. The waste volume in the current baseline program can be managed within the existing tank capacity. However, this requires implementation of some risk management actions and significant investment in software and hardware to accomplish the actions necessary to maximize use of existing storage tank space.''

  9. Natural convection in enclosures. Proceedings of the nineteenth national heat transfer conference, Orlando, FL, July 27-30, 1980

    International Nuclear Information System (INIS)

    Torrance, K.E.; Catton, I.

    1980-01-01

    Natural convection in low aspect ratio rectangular enclosures is considered along with three-dimensional convection within rectangular boxes, natural convection flow visualization in irradiated water cooled by air flow over the surface, free convection in vertical slots, the stratification in natural convection in vertical enclosures, the flow structure with natural convection in inclined air-filled enclosures, and natural convection across tilted, rectangular enclosures of small aspect ratio. Attention is given to the effect of wall conduction and radiation on natural convection in a vertical slot with uniform heat generation of the heated wall, a numerical study of thermal insulation enclosure, free convection in a piston-cylinder enclosure with sinusoidal piston motion, natural convection heat transfer between bodies and their spherical enclosure, an experimental study of the steady natural convection in a horizontal annulus with irregular boundaries, three-dimensional natural convection in a porous medium between concentric inclined cylinders, a numerical solution for natural convection in concentric spherical annuli, and heat transfer by natural convection in porous media between two concentric spheres

  10. Multi-functionalized side-chain supramolecular polymers: A methodology towards tunable functional materials

    Science.gov (United States)

    Nair, Kamlesh Prabhakaran

    Even as we see a significant growth in the field of supramolecular polymers in the last ten years, multi-functionalized systems have been scarcely studied. Noncovalent multi-functionalization provides unique advantages such as rapid materials optimization via reversible functionalization as well as for the tuning of materials properties by exploiting the differences in the nature of these reversible interactions. This thesis involves the design principles, synthesis & methodology of supramolecular side-chain multi-functionalized polymers. The combination of a functionally tolerant & controlled polymerization technique such as ROMP with multiple noncovalent interactions such as hydrogen bonding, metal coordination and ionic interactions has been successfully used to synthesize these polymers. Furthermore, the orthogonality between the above interactions in block/random copolymers has been studied in detail. It has been found that the studied interactions were orthogonal to each other. To validate the viability of this methodology using multiple orthogonal interactions towards materials design noncovalent crosslinking of polymers has been used as a potential application. Three classes of networks have been studied: complementary multiple hydrogen bonded networks, metal crosslinked networks, & multi-functionalized hydrogen bonded and metal coordinated networks. The first room temperature decrosslinking by exclusive complementary hydrogen bonded interactions has been successfully achieved. Furthermore network properties have been successfully tuned by varying the network micro-structure which in turn was tuned by the hydrogen bonding motifs used for inter-chain crosslinking. By combining two different noncovalent interactions used for inter-chain crosslinking, it was possible to make multi-functionalized materials whose properties could be controlled by varying the crosslinking strategy. Hence by employing multi-functionalization methodology, important materials

  11. Noise pollution of air compressor and its noise reduction procedures by using an enclosure

    Directory of Open Access Journals (Sweden)

    Farhad Forouharmajd

    2012-01-01

    Conclusions: An overall noise reduction by 25 dB with the use of mineral wool as an extra liner on the inside of the enclosure, suggests that the effectiveness of the enclosure can be increased by using such absorber materials.

  12. MAVL wastes containers functional demonstration and associated tests program

    International Nuclear Information System (INIS)

    Templier, J.C.

    2002-01-01

    In the framework of studies on the MAVL wastes, the CEA develops containers for middle time wastes storage. This program aims to realize a ''B wastes containers'' demonstrator. A demonstrator is a container, parts of a container or samples which must validate the tests. This document presents the state of the study in the following three chapters: functions description, base data and design choices; presentation of the functional demonstrators; demonstration tests description. (A.L.B.)

  13. NUMERICAL STUDY OF NON-DARCIAN NATURAL CONVECTION HEAT TRANSFER IN A RECTANGULAR ENCLOSURE FILLED WITH POROUS MEDIUM SATURATED WITH VISCOUS FLUID

    Directory of Open Access Journals (Sweden)

    Mahmood H. Ali

    2015-02-01

    Full Text Available A numerical study of non-Darcian natural convection heat transfer in a rectangular enclosure filled with porous medium saturated with viscous fluid was carried out. The effects of medium Rayleigh number, porosity, particle to fluid thermal conductivity ratio, Darcy number and enclosure aspect ratio on heat transfer were examined to demonstrate the ability of using this construction in thermal insulation of buildings walls.A modified Brinkman-Forchheimer-extended Darcy flow model was used and no-slip boundary conditions were imposed for velocity at the walls and the governing equations were expressed in dimensionless stream function, vorticity, and temperature formulation. The resulting algebraic equations obtained from finite difference discritization of vorticity and temperature equations are solved using (ADI method which uses Three Diagonal Matrix Algorithm (TDMA in each direction, while that of the stream function equation solved using successive iteration method.The study was done for the range of enclosure aspect ratio ( which is in the tall layers region at medium Rayleigh number ( , Darcy number (Da=10-3, 10-4, 10-5 , porosity (e=0.35, 0.45, 0.55, particle to fluid thermal conductivity (kS/kf=5.77, 38.5, 1385.5.The results showed that the Nusselt number is direct proportional to medium Rayleigh number and porosity and reversely proportional to Darcy number, ratio of particle to fluid thermal conductivity and enclosure aspect ratio. The variables that affect the heat transfer in the above arrangement was correlated in a mathematical equation that account better for their affects on heat transfer which is represented by mean Nusselt number (Nu.

  14. Underground disposal of hazardous waste in the Federal Republic of Germany - principles and policies

    International Nuclear Information System (INIS)

    Brewitz, W.; Brasser, T.

    1991-01-01

    In the Federal Republic of Germany the final disposal of radioactive waste and the permanent enclosure of defined types of toxic wastes in deep geological formations are being pursued with a view towards preventing hazardous material from reaching the biosphere. A detailed site- and waste-specific safety analysis will be required to substantiate the effiency of underground repositories. In this respect the longterm behaviour of wastes and possible interactions need to be evaluated, taking into consideration the geochemical-hydrogeological conditions such as groundwater movement and solution potentials. (au)

  15. Waste Package and Material Testing for the Proposed Yucca Mountain High Level Waste Repository

    International Nuclear Information System (INIS)

    Doering, Thomas; Pasupathi, V.

    2002-01-01

    Over the repository lifetime, the waste package containment barriers will perform various functions that will change with time. During the operational period, the barriers will function as vessels for handling, emplacement, and waste retrieval (if necessary). During the years following repository closure, the containment barriers will be relied upon to provide substantially complete containment, through 10,000 years and beyond. Following the substantially complete containment phase, the barriers and the waste package internal structures help minimize release of radionuclides by aqueous- and gaseous-phase transport. These requirements have lead to a defense-in-depth design philosophy. A multi-barrier design will result in a lower breach rate distributed over a longer period of time, thereby ensuring the regulatory requirements are met. The design of the Engineered Barrier System (EBS) has evolved. The initial waste package design was a thin walled package, 3/8 inch of stainless steel 304, that had very limited capacity, (3 PWR and 4 BWR assemblies) and performance characteristics, 300 to 1,000 years. This design required over 35,000 waste packages compared to today's design of just over 10,000 waste packages. The waste package designs are now based on a defense-in-depth/multi-barrier philosophy and have a capacity similar to the standard storage and rail transported spent nuclear fuel casks. Concurrent with the development of the design of the waste packages, a comprehensive waste package materials testing program has been undertaken to support the selection of containment barrier materials and to develop predictive models for the long-term behavior of these materials under expected repository conditions. The testing program includes both long-term and short-term tests and the results from these tests combination with the data published in the open literature are being used to develop models for predicting performance of the waste packages

  16. A sealed enclosure of the glove box type

    International Nuclear Information System (INIS)

    Moreels, Pierre.

    1974-01-01

    The invention relates to a sealed enclosure of the glove-box type. According to the invention, the box-frame comprises: angle-bars having a right-angled cross-section, sealing joints, tightening bars and fastening means [fr

  17. Impermeable Graphite: A New Development for Embedding Radioactive Waste

    International Nuclear Information System (INIS)

    Fachinger, Johannes

    2016-01-01

    Irradiated graphite has to be handled as radioactive waste after the operational period of the reactor. However, the waste management of irradiated graphite e.g. from the Spanish Vandellos reactor shows, that waste management of even low contaminated graphite could be expensive and requires special retrieval, treatment and disposal technologies for safe long term storage as low or medium radioactive waste. FNAG has developed an impermeable graphite matrix (IGM) as nuclear waste embedding material. This IGM provides a long term stable enclosure of radioactive waste and can reuse irradiated graphite as feedstock material. Therefore, no additional disposal volume is required if e.g. concrete waste packages were replaced by IGM waste packages. The variability of IGM as embedding has been summarized in the following paper usable for metal scraps, ion exchange resins or debris from buildings. Furthermore the main physical, chemical and structural properties are described. (author)

  18. A multi-criteria assessment of scenarios on thermal processing of infectious hospital wastes: A case study for Central Macedonia

    International Nuclear Information System (INIS)

    Karagiannidis, A.; Papageorgiou, A.; Perkoulidis, G.; Sanida, G.; Samaras, P.

    2010-01-01

    In Greece more than 14,000 tonnes of infectious hospital waste are produced yearly; a significant part of it is still mismanaged. Only one off-site licensed incineration facility for hospital wastes is in operation, with the remaining of the market covered by various hydroclave and autoclave units, whereas numerous problems are still generally encountered regarding waste segregation, collection, transportation and management, as well as often excessive entailed costs. Everyday practices still include dumping the majority of solid hospital waste into household disposal sites and landfills after sterilization, still largely without any preceding recycling and separation steps. Discussed in the present paper are the implemented and future treatment practices of infectious hospital wastes in Central Macedonia; produced quantities are reviewed, actual treatment costs are addressed critically, whereas the overall situation in Greece is discussed. Moreover, thermal treatment processes that could be applied for the treatment of infectious hospital wastes in the region are assessed via the multi-criteria decision method Analytic Hierarchy Process. Furthermore, a sensitivity analysis was performed and the analysis demonstrated that a centralized autoclave or hydroclave plant near Thessaloniki is the best performing option, depending however on the selection and weighing of criteria of the multi-criteria process. Moreover the study found that a common treatment option for the treatment of all infectious hospital wastes produced in the Region of Central Macedonia, could offer cost and environmental benefits. In general the multi-criteria decision method, as well as the conclusions and remarks of this study can be used as a basis for future planning and anticipation of the needs for investments in the area of medical waste management.

  19. A Large Hemi-Anechoic Enclosure for Community-Compatible Aeroacoustic Testing of Aircraft Propulsion Systems

    Science.gov (United States)

    Cooper, Beth A.

    1993-01-01

    A large hemi-anechoic (absorptive walls and acoustically hard floor) noise control enclosure has been erected around a complex of test stands at the NASA Lewis Research Center in Cleveland, Ohio. This new state-of-the-art Aeroacoustic Propulsion Laboratory (APL) provides an all-weather, semisecure test environment while limiting noise to acceptable levels in surrounding residential neighborhoods. The 39.6 m (130 ft) diameter geodesic dome structure houses the new Nozzle Aeroacoustic Test Rig (NATR), an ejector-powered M = 0.3 free jet facility for acoustic testing of supersonic aircraft exhaust nozzles and turbomachinery. A multi-axis, force-measuring Powered Lift Facility (PLF) stand for testing of Short Takeoff Vertical Landing (STOVL) vehicles is also located within the dome. The design of the Aeroacoustic Propulsion Laboratory efficiently accomodates the research functions of two separate test rigs, one of which (NATR) requires a specialized environment for taking acoustic measurements. Absorptive fiberglass wedge treatment on the interior surface of the dome provides a hemi-anechoic interior environment for obtaining the accurate acoustic measurements required to meet research program goals. The APL is the first known geodesic dome structure to incorporate transmission-loss properties as well as interior absorption into a free-standing, community-compatible, hemi-anechoic test facility.

  20. Retrofit of a MultiFamily Mass Masonry Building in New England

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Somerville, MA (United States); Kerrigan, P. [Building Science Corporation, Somerville, MA (United States); Wytrykowska, H. [Building Science Corporation, Somerville, MA (United States); Van Straaten, R. [Building Science Corporation, Somerville, MA (United States)

    2013-08-01

    Merrimack Valley Habitat for Humanity (MVHfH) has partnered with Building Science Corporation to provide high performance affordable housing for 10 families in the retrofit of an existing brick building (a former convent) into condominiums. The research performed for this project provides information regarding advanced retrofit packages for multi-family masonry buildings in Cold climates. In particular, this project demonstrates safe, durable, and cost-effective solutions that will potentially benefit millions of multi-family brick buildings throughout the East Coast and Midwest (Cold climates). The retrofit packages provide insight on the opportunities for and constraints on retrofitting multifamily buildings with ambitious energy performance goals but a limited budget. The condominium conversion project will contribute to several areas of research on enclosures, space conditioning, and water heating. Enclosure items include insulation of mass masonry building on the interior, airtightness of these types of retrofits, multi-unit building compartmentalization, window selection, and roof insulation strategies. Mechanical system items include combined hydronic and space heating systems with hydronic distribution in small (low load) units, and ventilation system retrofits for multifamily buildings.

  1. Enclosure for small animals during awake animal imaging

    Science.gov (United States)

    Goddard, Jr., James S

    2013-11-26

    An enclosure or burrow restrains an awake animal during an imaging procedure. A tubular body, made from a radiolucent material that does not attenuate x-rays or gamma rays, accepts an awake animal. A proximal end of the body includes an attachment surface that corresponds to an attachment surface of an optically transparent and optically uniform window. An anti-reflective coating may be applied to an inner surface, an outer surface, or both surfaces of the window. Since the window is a separate element of the enclosure and it is not integrally formed as part of the body, it can be made with optically uniform thickness properties for improved motion tracking of markers on the animal with a camera during the imaging procedure. The motion tracking information is then used to compensate for animal movement in the image.

  2. The influence of enclosure design on diurnal activity and stereotypic behaviour in captive Malayan Sun bears (Helarctos malayanus).

    Science.gov (United States)

    Tan, H M; Ong, S M; Langat, G; Bahaman, A R; Sharma, R S K; Sumita, S

    2013-04-01

    The effect of enclosure design on diurnal activity and stereotypic behaviour was assessed in 17 adult Malayan Sun bears (Helarctos malayanus), kept either in barren indoor enclosures or relatively enriched outdoor enclosures. Locomotion was the most frequent activity observed in the indoor bears, followed by resting. In contrast, conspecifics housed outdoors spent most of the time resting. Eleven forms of stereotypic behaviours were recorded in the bears, with pacing being the most common. The frequency and repertoire of stereotypies were significantly higher in the indoor bears irrespective of enclosure size. Novel forms of locomotor (forward-reverse pacing) and oral (allo-sucking) stereotypies were recorded. Oral stereotypies were predominant in the bears housed indoors, while patrolling was confined to the outdoor bears. Enclosure complexity significantly influences activity budget and occurrence of stereotypic behaviours, highlighting the importance of appropriate enclosure design and enrichment for the welfare of captive bears. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Structural and functional analysis of multi-interface domains.

    Directory of Open Access Journals (Sweden)

    Liang Zhao

    Full Text Available A multi-interface domain is a domain that can shape multiple and distinctive binding sites to contact with many other domains, forming a hub in domain-domain interaction networks. The functions played by the multiple interfaces are usually different, but there is no strict bijection between the functions and interfaces as some subsets of the interfaces play the same function. This work applies graph theory and algorithms to discover fingerprints for the multiple interfaces of a domain and to establish associations between the interfaces and functions, based on a huge set of multi-interface proteins from PDB. We found that about 40% of proteins have the multi-interface property, however the involved multi-interface domains account for only a tiny fraction (1.8% of the total number of domains. The interfaces of these domains are distinguishable in terms of their fingerprints, indicating the functional specificity of the multiple interfaces in a domain. Furthermore, we observed that both cooperative and distinctive structural patterns, which will be useful for protein engineering, exist in the multiple interfaces of a domain.

  4. Waste encapsulation and storage facility function analysis report

    International Nuclear Information System (INIS)

    Lund, D.P.

    1995-09-01

    The document contains the functions, function definitions, function interfaces, function interface definitions, Input Computer Automated Manufacturing Definition (IDEFO) diagrams, and a function hierarchy chart that describe what needs to be performed to deactivate Waste Encapsulation and Storage Facility (WESF)

  5. Electromagnetic coupling between transmitters and electro-explosive devices located within an enclosure.

    Energy Technology Data Exchange (ETDEWEB)

    Warne, Larry Kevin; Jorgenson, Roy Eberhardt; Coats, Rebecca Sue

    2010-04-01

    This report documents calculations conducted to determine if 42 low-power transmitters located within a metallic enclosure can initiate electro-explosive devices (EED) located within the same enclosure. This analysis was performed for a generic EED no-fire power level of 250 mW. The calculations show that if the transmitters are incoherent, the power available is 32 mW - approximately one-eighth of the assumed level even with several worst-case assumptions in place.

  6. Optimizing the design and impact behavior of a polymeric enclosure

    International Nuclear Information System (INIS)

    Singh, R.; Mattoo, A.; Saigal, A.

    2006-01-01

    This paper focuses on the application of finite element analysis to design an electronic enclosure with improved impact resistance properties. With the growing push towards miniaturization there is a constant decrease in the wall thickness of the enclosure applications. This necessitates use of ribs to enhance the impact resistance. This study aims at investigating optimal design of ribs for improving impact resistance. The 'DSGZ' phenomenological constitutive model, which uniformly describes the entire range of stress-strain constitutive relationship of polymers under any monotonic loading mode is used to predict the plastic failure energies. Several simulation runs were performed based on the design parameters using a 2 3 factorial design of experiments. The results from these simulations were used to analyze and study the various design parameters and its influence on the impact energy. It was found that when designing enclosures with ribs with an objective to maximize the impact failure energy, stress should be laid on optimizing the ratio of wall thickness to rib height within permissible limits while center-to-center spacing between the ribs and rib thickness do not have a significant effect

  7. Optimizing the design and impact behavior of a polymeric enclosure

    Energy Technology Data Exchange (ETDEWEB)

    Singh, R. [Department of Mechanical Engineering, Tufts University, Medford, MA 02155 (United States); Mattoo, A. [Department of Mechanical Engineering, Tufts University, Medford, MA 02155 (United States); Saigal, A. [Department of Mechanical Engineering, Tufts University, Medford, MA 02155 (United States)]. E-mail: anil.saigal@tufts.edu

    2006-07-01

    This paper focuses on the application of finite element analysis to design an electronic enclosure with improved impact resistance properties. With the growing push towards miniaturization there is a constant decrease in the wall thickness of the enclosure applications. This necessitates use of ribs to enhance the impact resistance. This study aims at investigating optimal design of ribs for improving impact resistance. The 'DSGZ' phenomenological constitutive model, which uniformly describes the entire range of stress-strain constitutive relationship of polymers under any monotonic loading mode is used to predict the plastic failure energies. Several simulation runs were performed based on the design parameters using a 2{sup 3} factorial design of experiments. The results from these simulations were used to analyze and study the various design parameters and its influence on the impact energy. It was found that when designing enclosures with ribs with an objective to maximize the impact failure energy, stress should be laid on optimizing the ratio of wall thickness to rib height within permissible limits while center-to-center spacing between the ribs and rib thickness do not have a significant effect.

  8. The Numerical Study on the Influence of Prandtl Number and Height of the Enclosure

    International Nuclear Information System (INIS)

    Moon, Je-Young; Chung, Bum-Jin

    2016-01-01

    This study investigated numerically the internal flow depending on Prandtl number of fluid and height of enclosure. The two-dimensional numerical simulations were performed for several heights of enclosure in the range between 0.01 m and 0.074 m. It corresponds to the aspect ratio (H/L) ranged from 0.07 to 0.5. Prandtl number was 0.2, 0.7 and 7. Rayleigh number based on the height of enclosure ranged between 8.49x10 3 and 1.20x10 8 . The numerical calculations were carried out using FLUENT 6.3. In order to confirm the influence of Prandtl number and height of side walls on the internal flow and heat transfer of the horizontal enclosure, the numerical study is carried out using the FLUENT 6.3. The numerical results for the condition of top cooling only agree well with Rayleigh-Benard natural convection. When the top and side walls were cooled, the internal flow of enclosure is more complex. The thickness of thermal and velocity boundary layer varies with Prandtl number. For Pr>1 the behavior of cells is unstable and irregular owing to the entrained plume, whereas the internal flow for Pr<1 is stable and regular. Also, the number of cells increases depending on decrease of height. As a result, the heat exchange increases

  9. Factors affecting wild rabbit production in extensive breeding enclosures: how can we optimise efforts?

    Directory of Open Access Journals (Sweden)

    José Guerrero-Casado

    2013-09-01

    Full Text Available The declining rabbit population in the Iberian Peninsula has led hunters and authorities to rear rabbits in captivity systems for their subsequent release. One alternative method to intensive rabbitry systems is the use of extensive breeding enclosures, since they produce animals of greater quality for hunting and conservation purposes. However, some of the factors that affect rabbit production in breeding enclosures are still unknown. The present study used partial least squares regression (PLSR to analyse the effects of plot size, scrub cover, slope, initial rabbit abundance, the resources needed to dig warrens, predation and proximity to other enclosures on rabbit abundance. The results of our study show a positive effect of the number of other fenced plots within a radius of 3 km, a positive relationship with the availability of optimal resources for building warrens and a positive influence of intermediate values of scrub cover. According to our results, to maximise rabbit production in the enclosures it would be advisable to concentrate the restocking effort by ensuring that the restocking plots are close to each other, thus avoiding isolated enclosures. Furthermore, the selection of plots with an appropriate scrub cover and high availability of elements that favour the construction of warrens, such as large stones, sloping land or tall shrubs, may optimise results.

  10. Experimental Study on Natural Convection Heat Transfer From two Parallel Horizontal Cylinders in Horizontal Cylindrical Enclosure

    Directory of Open Access Journals (Sweden)

    Ahmed T. Ahmed

    2013-05-01

    Full Text Available  An experimental study on natural convection heat transfer from two parallel horizontal cylinders in horizontal cylindrical enclosure was carried out under condition of constant surfaces temperature for two cylinders and cylindrical enclosure. The study included the effect of Rayleigh number, rotation angle that represent the confined angle between the passing horizontal plane in cylindrical enclosure center and passing line in two cylinders centers, and the spaces between two cylinders on their heat loss ability.39An experimental set-up was used for this purpose which consist watercontainer, test section which is formed of plastic cylinder that represent the cylindrical enclosure, and two heating elements which are formed of two copper cylinders with (19 mm in diameters heated internally by electrical sources that represents transfer and heat loss elements through this set-up.      The experiments were done at the range of Rayleigh number between ( , cylinders rotation angle at ( , and spacing ratio at ( .     The study showed that the ability of heat loss from two cylinders is a function of Rayleigh number, cylinders rotation angle, and the spaces between them. This ability is increased by increasing of Rayleigh number and it was showed that this ability reaches maximum value at the first cylinder ( and minimum value at the second cylinder ( at spacing ratio (S/D=3 and rotation angle ( for the first and ( for the second cylinder respectively.      The effective variables on natural convection heat transfer from the above two cylinders are related by two correlating equations, each one explains dimensionless relation of heat transfer from each cylinder that represented by Nusselt number against Rayleigh number, rotation angle, and the spacing ratio between two cylinders. 

  11. Application of tuned sound enclosures to transformers

    International Nuclear Information System (INIS)

    Allan, K.N.; Ellingson, E.F.

    1992-09-01

    The objective of this program was to reduce the noise emitted from power transformers by using a close-fitting, integrally-mounted noise shell. The noise shell consists of a series of panels mounted to a framework, that is, in turn, supported by the tank by means of mounting brackets and neoprene isolators. The development work was directed specifically toward application to existing transformers, i.e. retrofit.This project is a follow-on to work done under project RP-579-1. That project developed the theory and applied it experimentally to an existing transformer. The results were somewhat disappointing, however, with an 8 dBA reduction achieved where 15 dBA was expected. This document reports the work performed covering the period from March 1, 1977, to December 31, 1978. A complete noise shell enclosure was installed on a transformer for Consumers Power Company (Jackson, Michigan). Costs projected on the basis of this installation and several business assumptions indicate an installed cost of 19.8% of a new, standard noise transformer. This is higher than originally expected, but lower than alternative noise control methods. It also has some features that should make it an even more attractive alternative. Material loss factor (generally termed damping) of the enclosure material was found to be a critical parameter. Addition of a damping treatment to the experimental shell increased the performance to the 15 dBA target reduction. Damping was also found to be critical on the demonstration unit. The plastic panels installed (loss factor 0.05) resulted in a noise reduction of 8.5 dBA, increasing to 11.6 dBA when acoustical foam was added inside the enclosure. Three panels were replaced with damped steel panels and an overall 16.5 dBA reduction is anticipated based on vibration measurements

  12. Flows and Stratification of an Enclosure Containing Both Localised and Vertically Distributed Sources of Buoyancy

    Science.gov (United States)

    Partridge, Jamie; Linden, Paul

    2013-11-01

    We examine the flows and stratification established in a naturally ventilated enclosure containing both a localised and vertically distributed source of buoyancy. The enclosure is ventilated through upper and lower openings which connect the space to an external ambient. Small scale laboratory experiments were carried out with water as the working medium and buoyancy being driven directly by temperature differences. A point source plume gave localised heating while the distributed source was driven by a controllable heater mat located in the side wall of the enclosure. The transient temperatures, as well as steady state temperature profiles, were recorded and are reported here. The temperature profiles inside the enclosure were found to be dependent on the effective opening area A*, a combination of the upper and lower openings, and the ratio of buoyancy fluxes from the distributed and localised source Ψ =Bw/Bp . Industrial CASE award with ARUP.

  13. Radioactive Waste Management Produced from the Generator Tc-99m Products

    International Nuclear Information System (INIS)

    Suhaedi Muhammad; Rimin Sumantri; Affan Ahmad; Tuyono

    2012-01-01

    Generator Tc-99m product is used in hospitals will result in radioactive waste both solid waste in the form of a column compacted Tc-99m Generator, bottles vials and bottles of saline fluid path series: burning of solid waste in the form of paper straw, hand gloves, and cardboard (vial packing boxes and wrapping Generator) and liquid waste form leaching results lead pot and enclosure. So that these wastes pose no radiological consequences for both humans and the environment, it must be properly managed in accordance with the provisions. In order to realize these expectations should be made so that the radioactive waste management system can be handled effectively, optimal, economical, safe and secure and in accordance with applicable regulations. Management system is in it include: procedures for handling radioactive waste, solid waste compacted, burning of solid waste management, liquid waste handling, shipment of radioactive waste and determination of the amount of radiation doses received by workers who handle radioactive waste. (author)

  14. Productivity of a coral reef using boundary layer and enclosure methods

    Science.gov (United States)

    McGillis, W.R.; Langdon, C.; Loose, B.; Yates, K.K.; Corredor, Jorge

    2011-01-01

    The metabolism of Cayo Enrique Reef, Puerto Rico, was studied using in situ methods during March 2009. Benthic O2 fluxes were used to calculate net community production using both the boundary layer gradient and enclosure techniques. The boundary layer O2 gradient and the drag coefficients were used to calculate productivity ranging from -12.3 to 13.7 mmol O2 m-2 h-1. Productivity measurements from the enclosure method ranged from -11.0 to 12.9 mmol O2 m-2 h-1. During the study, the mean hourly difference between the methods was 0.65 mmol O2 m-2 h-1 (r2 = 0.92), resulting in well-reconciled estimates of net community production between the boundary layer (-33.1 mmol m-2 d-1) and enclosure (-46.3 mmol m-2 d-1) techniques. The results of these independent approaches corroborate quantified rates of metabolism at Cayo Enrique Reef. Close agreement between methods demonstrates that boundary layer measurements can provide near real-time assessments of coral reef health.

  15. Quasilinear parabolic variational inequalities with multi-valued lower-order terms

    Science.gov (United States)

    Carl, Siegfried; Le, Vy K.

    2014-10-01

    In this paper, we provide an analytical frame work for the following multi-valued parabolic variational inequality in a cylindrical domain : Find and an such that where is some closed and convex subset, A is a time-dependent quasilinear elliptic operator, and the multi-valued function is assumed to be upper semicontinuous only, so that Clarke's generalized gradient is included as a special case. Thus, parabolic variational-hemivariational inequalities are special cases of the problem considered here. The extension of parabolic variational-hemivariational inequalities to the general class of multi-valued problems considered in this paper is not only of disciplinary interest, but is motivated by the need in applications. The main goals are as follows. First, we provide an existence theory for the above-stated problem under coercivity assumptions. Second, in the noncoercive case, we establish an appropriate sub-supersolution method that allows us to get existence, comparison, and enclosure results. Third, the order structure of the solution set enclosed by sub-supersolutions is revealed. In particular, it is shown that the solution set within the sector of sub-supersolutions is a directed set. As an application, a multi-valued parabolic obstacle problem is treated.

  16. Effects of Dredging and Lanthanum-Modified Clay on Water Quality Variables in an Enclosure Study in a Hypertrophic Pond

    Directory of Open Access Journals (Sweden)

    Miquel Lürling Guido Waajen

    2017-05-01

    Full Text Available An enclosure experiment was conducted between July and September 2009 to compare the effectiveness of a phosphate fixative, the lanthanum-modified bentonite clay Phoslock® (LMB, dredging, and their combination in controlling eutrophication in a hypertrophic urban pond in Heesch, The Netherlands. In total, 25 water quality variables were monitored. Multivariate analysis revealed that the combination LMB-treated and dredged enclosures deviated most from the pond (reference and the controls, and showed the strongest eutrophication reduction. Overall, dredging significantly increased transparency, lowered turbidity, and improved the oxygen conditions in the enclosures compared to non-dredged ones. Nonetheless, one dredged enclosure deviated dramatically from the others, which might reflect methodological issues with dredging. The LMB treatment appeared to be less effective at mitigating eutrophication than dredging, and phosphate concentrations even increased during the experiment in the LMB-treated enclosures. Chemical equilibrium modeling suggested that humic substances could have formed complexes with lanthanum (La from the LMB, rendering it unavailable for intercepting P over the course of the enclosure experiment. Residual lanthanum concentrations in combination dredging and LMB treatments exceeded the Dutch standard 10-fold. Total zooplankton abundance, and particularly Cladocera, increased in all enclosures over the course of the experiment. The limited effect of LMB in the enclosure experiment and the violation of the Dutch La standard when combined with dredging disqualify LMB as an intervention agent in the restoration of the pond.

  17. A multiobjective modeling approach to locate multi-compartment containers for urban-sorted waste

    International Nuclear Information System (INIS)

    Tralhao, Lino; Coutinho-Rodrigues, Joao; Alcada-Almeida, Luis

    2010-01-01

    The location of multi-compartment sorted waste containers for recycling purposes in cities is an important problem in the context of urban waste management. The costs associated with those facilities and the impacts placed on populations are important concerns. This paper introduces a mixed-integer, multiobjective programming approach to identify the locations and capacities of such facilities. The approach incorporates an optimization model in a Geographical Information System (GIS)-based interactive decision support system that includes four objectives. The first objective minimizes the total investment cost; the second one minimizes the average distance from dwellings to the respective multi-compartment container; the last two objectives address the 'pull' and 'push' characteristics of the decision problem, one by minimizing the number of individuals too close to any container, and the other by minimizing the number of dwellings too far from the respective multi-compartment container. The model determines the number of facilities to be opened, the respective container capacities, their locations, their respective shares of the total waste of each type to be collected, and the dwellings assigned to each facility. The approach proposed was tested with a case study for the historical center of Coimbra city, Portugal, where a large urban renovation project, addressing about 800 buildings, is being undertaken. This paper demonstrates that the models and techniques incorporated in the interactive decision support system (IDSS) can be used to assist a decision maker (DM) in analyzing this complex problem in a realistically sized urban application. Ten solutions consisting of different combinations of underground containers for the disposal of four types of sorted waste in 12 candidate sites, were generated. These solutions and tradeoffs among the objectives are presented to the DM via tables, graphs, color-coded maps and other graphics. The DM can then use this

  18. Multi-function nuclear weight scale system

    International Nuclear Information System (INIS)

    Zheng Mingquan; Sun Jinhua; Jia Changchun; Wang Mingqian; Tang Ke

    1998-01-01

    The author introduces the methods to contrive the hardware and software of a Multi-function Nuclear Weight Scale System based on the communication contract in compliance with RS485 between a master (industrial control computer 386) and a slave (single chip 8098) and its main functions

  19. Limiting enclosures. Method of control of the leak rate per hour. Enclosures of classes 1 and 2. Method of measurement of the increase of the oxygen titre in volume

    International Nuclear Information System (INIS)

    1984-07-01

    The present standard can be applied to limiting enclosures working under depression or overpressure. It can be applied to limiting enclosures used for works on radioactive or toxic materials. The leak rate per hour is -2 h -1 . The measuring method uses oxygen determination after the enclusore is filled with an inert gas. The influence of pressure and temperature are analysed. The measurement installation and its operating way are presented; the accuracy of the method given. This standard supersedes the experimental standard of December 1982 [fr

  20. Direct simulation of natural convection in square porous enclosure

    International Nuclear Information System (INIS)

    Pourshaghaghy, A.; Hakkaki-Fard, A.; Mahdavi-Nejad, A.

    2007-01-01

    In this article, natural convection in a square porous enclosure is simulated by a direct numerical method. The solution method is based on a random distribution of solid blocks, which resembles the porous media within the cavity. The Navier-Stokes equations are solved directly in the fluid region without the assumption of volume averaging. The no-slip condition is applied on the surface of any solid particle, and the energy transport equation is solved separately for the solid phase and fluid flow. The local and average Nusselt numbers are presented for steady state for two different cases of thermal boundary conditions of the cavity walls. An oscillatory solution is observed for the local Nu number on the surface of the enclosure, and the critical Ra numbers are found in which natural convection flow is started within the cavity

  1. Acoustic Pressure Waves in Vibrating 3-D Laminated Beam-Plate Enclosures

    Directory of Open Access Journals (Sweden)

    Charles A. Osheku

    2009-01-01

    Full Text Available The effect of structural vibration on the propagation of acoustic pressure waves through a cantilevered 3-D laminated beam-plate enclosure is investigated analytically. For this problem, a set of well-posed partial differential equations governing the vibroacoustic wave interaction phenomenon are formulated and matched for the various vibrating boundary surfaces. By employing integral transforms, a closed form analytical expression is computed suitable for vibroacoustic modeling, design analysis, and general aerospace defensive applications. The closed-form expression takes the form of a kernel of polynomials for acoustic pressure waves showing the influence of linear interface pressure variation across the axes of vibrating boundary surfaces. Simulated results demonstrate how the mode shapes and the associated natural frequencies can be easily computed. It is shown in this paper that acoustic pressure waves propagation are dynamically stable through laminated enclosures with progressive decrement in interfacial pressure distribution under the influence of high excitation frequencies irrespective of whether the induced flow is subsonic, sonic , supersonic, or hypersonic. Hence, in practice, dynamic stability of hypersonic aircrafts or jet airplanes can be further enhanced by replacing their noise transmission systems with laminated enclosures.

  2. Modeling of humidity-related reliability in enclosures with electronics

    DEFF Research Database (Denmark)

    Hygum, Morten Arnfeldt; Popok, Vladimir

    2015-01-01

    Reliability of electronics that operate outdoor is strongly affected by environmental factors such as temperature and humidity. Fluctuations of these parameters can lead to water condensation inside enclosures. Therefore, modelling of humidity distribution in a container with air and freely exposed...

  3. Multi-point injection demonstration for solidification of shallow buried waste at Oak Ridge Reservation, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1996-10-01

    The multi-point injection (MPI) technology is a precision, high-velocity jetting process for the in situ delivery of various agents to treat radiological and/or chemical wastes. A wide variety of waste forms can be treated, varying from heterogeneous waste dumped into shallow burial trenches to contaminated soils consisting of sands/gravels, silts/clays and soft rock. The robustness of the MPI system is linked to its broad range of applications which vary from in situ waste treatment to creation of both vertical and horizontal barriers. The only major constraint on the type of in situ treatment which can be delivered by the NTI system is that agents must be in a slurry form

  4. The waste-to-energy framework for integrated multi-waste utilization: Waste cooking oil, waste lubricating oil, and waste plastics

    Energy Technology Data Exchange (ETDEWEB)

    Singhabhandhu, Ampaitepin; Tezuka, Tetsuo [Energy Economics Laboratory, Department of Socio-Environmental Energy Science, Graduate School of Energy Science, Kyoto University, Yoshida-honmachi, Sakyo-ku, Kyoto 606-8501 (Japan)

    2010-06-15

    Energy generation by wastes is considered one method of waste management that has the benefit of energy recovery. From the waste-to-energy point of view, waste cooking oil, waste lubricating oil, and waste plastics have been considered good candidates for feedstocks for energy conversion due to their high heating values. Compared to the independent management of these three wastes, the idea of co-processing them in integration is expected to gain more benefit. The economies of scale and the synergy of co-processing these wastes results in higher quality and higher yield of the end products. In this study, we use cost-benefit analysis to evaluate the integrated management scenario of collecting the three wastes and converting them to energy. We report the total heat of combustion of pyrolytic oil at the maximum and minimum conversion rates, and conduct a sensitivity analysis in which the parameters of an increase of the electricity cost for operating the process and increase of the feedstock transportation cost are tested. We evaluate the effects of economy of scale in the case of integrated waste management. We compare four cases of waste-to-energy conversion with the business as usual (BAU) scenario, and our results show that the integrated co-processing of waste cooking oil, waste lubricating oil, and waste plastics is the most profitable from the viewpoints of energy yield and economics. (author)

  5. An inexact reverse logistics model for municipal solid waste management systems.

    Science.gov (United States)

    Zhang, Yi Mei; Huang, Guo He; He, Li

    2011-03-01

    This paper proposed an inexact reverse logistics model for municipal solid waste management systems (IRWM). Waste managers, suppliers, industries and distributors were involved in strategic planning and operational execution through reverse logistics management. All the parameters were assumed to be intervals to quantify the uncertainties in the optimization process and solutions in IRWM. To solve this model, a piecewise interval programming was developed to deal with Min-Min functions in both objectives and constraints. The application of the model was illustrated through a classical municipal solid waste management case. With different cost parameters for landfill and the WTE, two scenarios were analyzed. The IRWM could reflect the dynamic and uncertain characteristics of MSW management systems, and could facilitate the generation of desired management plans. The model could be further advanced through incorporating methods of stochastic or fuzzy parameters into its framework. Design of multi-waste, multi-echelon, multi-uncertainty reverse logistics model for waste management network would also be preferred. Copyright © 2010 Elsevier Ltd. All rights reserved.

  6. Modeling and Eigenfrequency Analysis of Sound-Structure Interaction in a Rectangular Enclosure with Finite Element Method

    Directory of Open Access Journals (Sweden)

    Samira Mohamady

    2009-01-01

    Full Text Available Vibration of structures due to external sound is one of the main causes of interior noise in cavities like automobile, aircraft, and rotorcraft, which disturb the comfort of passengers. Accurate modelling of such phenomena is required in eigenfrequency analysis and in designing an active noise control system to reduce the interior noise. In this paper, the effect of periodic noise travelling into a rectangular enclosure is investigated with finite element method (FEM using COMSOL Multiphysics software. The periodic acoustic wave is generated by a point source outside the enclosure and propagated through the enclosure wall and excites an aluminium flexible panel clamped onto the enclosure. The behaviour of the transmission of sound into the cavity is investigated by computing the modal characteristics and the natural frequencies of the cavity. The simulation results are compared with previous analytical and experimental works for validation and an acceptable match between them were obtained.

  7. Applying multi-criteria analysis to radiation protection optimisation of low and intermediate level radioactive waste disposal

    International Nuclear Information System (INIS)

    Pages, P.; Schneider, T.; Lombard, J.

    1991-01-01

    Introduction of ALARA principles in the field of radioactive waste management implies a definition of the main characteristics of the decisional framework. Specific aspects should be taken into account: long term effects, large uncertainties and/or probabilistic events, with particular attention to the public and the political authorities. Traditional cost-benefit analysis is not qualified to deal with these different dimensions of the risk. The aim of this paper is to describe the principles of multi-criteria analysis applied to low and intermediate level radioactive waste disposal. Three categories of barriers can be distinguished acting at different protection levels: site characteristics, waste package and disposal system. A set of possible solutions can be identified, but the selection of the 'optimum' is not easy because of the diversity of the factors to be allowed for. For example, the following problem needs to be addressed: is it preferable to limit public radiation exposure several hundred years ahead or to reduce occupational exposure during the monitoring period of the disposal facility? An optimisation study is currently being performed on the various components of the structure, assuming given site and waste package characteristics. Four steps are distinguished: identification and analysis of options for the structure; selection and estimation of the qualitative and quantitative criteria; determination of the 'most interesting' solutions using multi-criteria analysis; sensitivity analysis and discussion on uncertainties related to the various assumptions. Based on the preliminary findings, the paper focuses on practical solutions to address the methodological issues raised in applying the optimisation procedures to radioactive waste management. (au)

  8. Supplemental design requirements document, Multifunction Waste Tank Facility, Project W-236A. Revision 1

    International Nuclear Information System (INIS)

    Groth, B.D.

    1995-01-01

    The Multi-Function Waste Tank Facility (MWTF) consists of four, nominal 1 million gallon, underground double-shell tanks, located in the 200-East area, and two tanks of the same capacity in the 200-West area. MWTF will provide environmentally safe storage capacity for wastes generated during remediation/retrieval activities of existing waste storage tanks. This document delineates in detail the information to be used for effective implementation of the Functional Design Criteria requirements

  9. The regulatory function in radioactive waste management

    International Nuclear Information System (INIS)

    Duncan, A.; Pescatore, C.

    2008-01-01

    Allan Duncan, expert to NEA and former Chief Inspector for Pollution (United Kingdom), elaborated on the regulatory function in the domain of radioactive waste management. The preparation of a document and a brochure on the subject has been one of the main tasks of the Regulators' Forum since its creation in 2001. He stressed that management of NORM waste was generally subject to different standards than similar radioactive waste from a nuclear source, for no obvious reason than that of public perception. He also pointed out the large number of 'regulatory bodies' involved in the regulation of radioactive waste management facilities and particularly geological disposal facilities, and their links to the Government. He gave the example of the United Kingdom. He stressed the fact that, since there will not be continuous control, licensing of geological disposal is an act of trust in the regulatory system. A. Duncan gave the position of two Commissions in England on deep geological disposal. The UK Sustainable Development Commission says, 'it is impossible to guarantee safety over long-term disposal of (nuclear) waste' which implies that nuclear fission power should be shut down; CoRWM, the Committee on Radioactive Waste Management, recommends instead geological disposal for existing wastes as a broadly acceptable solution. As a concluding remark A. Duncan focused the attention on the general question of what current society needs to do in order to meet its obligations to future generations with respect to disposal of long-lived wastes. (authors)

  10. Double-diffusive mixed convection in the slot ventilated enclosure with different arrangements of supplying air flow ports

    Directory of Open Access Journals (Sweden)

    Heng-Sheng Cheng

    2015-03-01

    Full Text Available Steady double-diffusive mixed convection in an enclosure with side venting and discrete heat and contaminant sources is numerically studied under supplying upside and returning downside (STRB mode and returning upside and supplying downside mode (RTSB, respectively. The parameters governing the fluid flow include the Grashof number Gr (102–106, Reynolds number Re (100–500, supplying or returning distance H 1/HT (0–2, Prandtl number Pr (0.7, buoyancy ratio N, and Schmidt number Sc. Effects of Gr, Re, and H 1/HT on the flow patterns, thermal, and species transports were numerically investigated concerning STRB and RTSB modes. Fluid flow, heat, and species transports in the enclosure are visualized and analyzed by the contours of stream function, heat function, and mass function, respectively. Air age was also presented to evaluate the freshness of the enclosed fluid. Averaged Nusselt number of the heat source and Sherwood number of the contaminant source are power-law correlated with Gr, Re, and H 1/HT for two ventilation modes, respectively. The correlations demonstrate that the ratio of averaged Nusselt number to Sherwood number was approximately approaching unity, independent of ventilation modes and values of H 1/HT . This investigation could benefit the future design of room ventilation and thermal removals from the electronic chips.

  11. Function analysis for waste information systems

    International Nuclear Information System (INIS)

    Sexton, J.L.; Neal, C.T.; Heath, T.C.; Starling, C.D.

    1996-04-01

    This study has a two-fold purpose. It seeks to identify the functional requirements of a waste tracking information system and to find feasible alternatives for meeting those requirements on the Oak Ridge Reservation (ORR) and the Portsmouth (PORTS) and Paducah (PGDP) facilities; identify options that offer potential cost savings to the US government and also show opportunities for improved efficiency and effectiveness in managing waste information; and, finally, to recommend a practical course of action that can be immediately initiated. In addition to identifying relevant requirements, it also identifies any existing requirements that are currently not being completely met. Another aim of this study is to carry out preliminary benchmarking by contacting representative companies about their strategic directions in waste information. The information obtained from representatives of these organizations is contained in an appendix to the document; a full benchmarking effort, however, is beyond the intended scope of this study

  12. Enhancing monochromatic multipole emission by a subwavelength enclosure of degenerate Mie resonances

    KAUST Repository

    Zhao, Jiajun

    2017-07-06

    Sound emission is inefficient at low frequencies as limited by source size. This letter presents enhancing emission of monochromatic monopole and multipole sources by enclosing the source with a subwavelength circular enclosure filled of an anisotropic material of a low radial sound speed. The anisotropy is associated with an infinite tangential density along the azimuth. Numerical simulations show that emission gain is produced at frequencies surrounding degenerate Mie resonant frequencies of the enclosure, and meanwhile the radiation directivity pattern is well preserved. The degeneracy is theoretically analyzed. A realization of the material is suggested by using a space-coiling structure.

  13. Analysis of moisture transport between connected enclosures under a forced thermal gradient

    DEFF Research Database (Denmark)

    Staliulionis, Zygimantas; Joshy, Salil; Ambat, Rajan

    2016-01-01

    and humidity control solutions. While high fidelity CFD codes are too time consuming due to computational effort/time, the well-known Resistor-Capacitor (RC) approach has much lower calculation time and is more efficient to use in enclosures without too complex geometry in their interior. Thus, the objective...... of this paper is to build an in-house code based on the RC approach for simulating coupled heat and mass transport. The developed code is used for simulating moisture transport between two boxes/enclosures having different temperatures, connected with a tube of known geometry. It has also the capability...

  14. Thermodynamic analysis and performance optimization of an ORC (Organic Rankine Cycle) system for multi-strand waste heat sources in petroleum refining industry

    International Nuclear Information System (INIS)

    Song, Jian; Li, Yan; Gu, Chun-wei; Zhang, Li

    2014-01-01

    Low-grade waste heat source accounts for a large part of the total industrial waste heat, which cannot be efficiently recovered. The ORC (Organic Rankine Cycle) system has been proved to be a promising solution for the utilization of low-grade heat sources. It is evident that there might be several waste heat sources distributing in different temperature levels in one industry unit, and the entire recovery system will be extremely large and complex if the different heat sources are utilized one by one through several independent ORC subsystems. This paper aims to design and optimize a comprehensive ORC system to recover multi-strand waste heat sources in Shijiazhuang Refining and Chemical Company in China, involving defining suitable working fluids and operating parameters. Thermal performance is a first priority criterion for the system, and system simplicity, technological feasibility and economic factors are considered during optimization. Four schemes of the recovery system are presented in continuous optimization progress. By comparison, the scheme of dual integrated subsystems with R141B as a working fluid is optimal. Further analysis is implemented from the view of economic factors and off-design conditions. The analytical method and optimization progress presented can be widely applied in similar multi-strand waste heat sources recovery. - Highlights: • This paper focuses on the recovery of multi-strand waste heat sources. • ORC technology is used as a promising solution for the recovery. • Thermal performance, system simplicity and economic factors are considered

  15. Mathematical modelling of moisture transport into an electronic enclosure under non-isothermal conditions

    DEFF Research Database (Denmark)

    Staliulionis, Ž.; Mohanty, S.; Jabbari, Mahmoud

    2017-01-01

    In contrast to high fidelity CFD codes which require higher computational effort/time, the well-known Resistor-Capacitor (RC) approach requires much lower calculation time, but has a lower resolution of the geometrical arrangement. Therefore, for enclosures without too complex geometry in their i......In contrast to high fidelity CFD codes which require higher computational effort/time, the well-known Resistor-Capacitor (RC) approach requires much lower calculation time, but has a lower resolution of the geometrical arrangement. Therefore, for enclosures without too complex geometry...

  16. Bio-Inspired Multi-Functional Drug Transport Design Concept and Simulations.

    Science.gov (United States)

    Pidaparti, Ramana M; Cartin, Charles; Su, Guoguang

    2017-04-25

    In this study, we developed a microdevice concept for drug/fluidic transport taking an inspiration from supramolecular motor found in biological cells. Specifically, idealized multi-functional design geometry (nozzle/diffuser/nozzle) was developed for (i) fluidic/particle transport; (ii) particle separation; and (iii) droplet generation. Several design simulations were conducted to demonstrate the working principles of the multi-functional device. The design simulations illustrate that the proposed design concept is feasible for multi-functionality. However, further experimentation and optimization studies are needed to fully evaluate the multifunctional device concept for multiple applications.

  17. Waste picker livelihoods and inclusive neoliberal municipal solid waste management policies: The case of the La Chureca garbage dump site in Managua, Nicaragua.

    Science.gov (United States)

    Hartmann, Chris

    2018-01-01

    The modernization (i.e. mechanization, formalization, and capital intensification) and enclosure of municipal solid waste management (MSWM) systems threaten waste picker livelihoods. From 2009 to 2013, a major development project, embodying traditional neoliberal policies with inclusive social policies, transformed the Managua, Nicaragua, municipal solid waste site from an open-air dump where as many as 2,000 informal waste pickers toiled to a sanitary landfill. To investigate waste pickers' social and economic condition, including labor characteristics, household income, and poverty incidence, after the project's completion, 146 semi-structured survey questionnaires were administered to four communities adjacent to the landfill and 45 semi-structured interviews were completed with key stakeholders. Findings indicate that hundreds of waste pickers were displaced by the project, employment benefits from the project were unevenly distributed by neighborhood, and informal waste picking endures due to persistent impoverishment, thereby contributing to continued social and economic marginalization and environmental degradation. The findings highlight the limitations of inclusive neoliberal development efforts to transform MSWM in a low-income country. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Free convective condensation in a vertical enclosure

    Energy Technology Data Exchange (ETDEWEB)

    Fox, R.J.; Peterson, P.F. [Univ. of California, Berkeley, CA (United States); Corradini, M.L.; Pernsteiner, A.P. [Univ. of Wisconsin, Madison, WI (United States)

    1995-09-01

    Free convective condensation in a vertical enclosure was studied numerically and the results were compared with experiments. In both the numerical and experimental investigations, mist formation was observed to occur near the cooling wall, with significant droplet concentrations in the bulk. Large recirculation cells near the end of the condensing section were generated as the heavy noncondensing gas collecting near the cooling wall was accelerated downward. Near the top of the enclosure the recirculation cells became weaker and smaller than those below, ultimately disappearing near the top of the condenser. In the experiment the mist density was seen to be highest near the wall and at the bottom of the condensing section, whereas the numerical model predicted a much more uniform distribution. The model used to describe the formation of mist was based on a Modified Critical Saturation Model (MCSM), which allows mist to be generated once the vapor pressure exceeds a critical value. Equilibrium, nonequilibrium, and MCSM calculations were preformed, showing the experimental results to lie somewhere in between the equilibrium and nonequilibrium predictions of the numerical model. A single adjustable constant (indicating the degree to which equilibrium is achieved) is used in the model in order to match the experimental results.

  19. Transient characteristics of thermal energy storage in an enclosure packed with MEPCM particles

    International Nuclear Information System (INIS)

    Siao, Yong-Hao; Yan, Wei-Mon; Lai, Chi-Ming

    2015-01-01

    The heat transfer characteristics of phase change materials have been of continuing interest of research due to various potential technical applications, such as the latent-heat thermal energy storage, thermal protection, as well as active/passive electronic cooling. In this work, the transient characteristics of thermal energy storage in a partitioned enclosure filled with microencapsulated phase change material (MEPCM) particles were investigated experimentally and numerically. To examine the different melting temperature effects, two different MEPCM particles are tested. The core phase change materials of the MEPCM are n-octadecane with melting temperature about T M  = 28 °C and 37 °C. The enclosure is partitioned and is differentially heated by the two horizontal isothermal surfaces, while the other vertical surfaces are considered thermally insulated. The studies have been undertaken for five sets of the hot and cold wall temperatures imposed across the enclosure. The consequents show that the numerical results are in agreement with the measured data. At the initial transient, the net energy storage in enclosure, Q net , increases with the time Fo. Finally, the Q net approaches quickly the steady state for the case with a higher temperature difference of T h  − T c . Additionally, higher dimensionless accumulated energy through the hot wall Q h and cold wall Q c is found for a case with higher hot wall temperature T h

  20. Multi-objective models of waste load allocation toward a sustainable reuse of drainage water in irrigation.

    Science.gov (United States)

    Allam, Ayman; Tawfik, Ahmed; Yoshimura, Chihiro; Fleifle, Amr

    2016-06-01

    The present study proposes a waste load allocation (WLA) framework for a sustainable quality management of agricultural drainage water (ADW). Two multi-objective models, namely, abatement-performance and abatement-equity-performance, were developed through the integration of a water quality model (QAUL2Kw) and a genetic algorithm, by considering (1) the total waste load abatement, and (2) the inequity among waste dischargers. For successfully accomplishing modeling tasks, we developed a comprehensive overall performance measure (E wla ) reflecting possible violations of Egyptian standards for ADW reuse in irrigation. This methodology was applied to the Gharbia drain in the Nile Delta, Egypt, during both summer and winter seasons of 2012. Abatement-performance modeling results for a target of E wla = 100 % corresponded to the abatement ratio of the dischargers ranging from 20.7 to 75.6 % and 29.5 to 78.5 % in summer and in winter, respectively, alongside highly shifting inequity values. Abatement-equity-performance modeling results for a target of E wla = 90 % unraveled the necessity of increasing treatment efforts in three out of five dischargers during summer, and four out of five in winter. The trade-off curves obtained from WLA models proved their reliability in selecting appropriate WLA procedures as a function of budget constraints, principles of social equity, and desired overall performance level. Hence, the proposed framework of methodologies is of great importance to decision makers working toward a sustainable reuse of the ADW in irrigation.

  1. Numerical analysis of a heat-generating, truncated conical porous bed in a fluid-filled enclosure

    International Nuclear Information System (INIS)

    Chakravarty, Aranyak; Datta, Priyankan; Ghosh, Koushik; Sen, Swarnendu; Mukhopadhyay, Achintya

    2016-01-01

    Analysis of natural convection in enclosures containing heat generating porous medium has important applications related to geothermal, chemical, thermal and nuclear energy such as in-vessel cooling of debris beds in nuclear reactors, cooling of coal stockpiles etc. The objective of the present numerical study is to characterise the pattern of fluid flow and energy transfer during steady laminar natural convective flow in a cylindrical enclosure with a centrally placed heat generating porous bed. Flow through porous region is modelled using Darcy–Brinkmann–Forchheimer model and local thermal equilibrium is assumed for the porous region. Analysis is carried out for a wide range of Rayleigh number (Ra), Darcy number (Da) and thermal conductivity ratio, as well as for different bed geometries. It is observed that in addition to Ra and Da, the bed geometry also plays a very important role in determining flow field and temperature distribution within the enclosure. Interestingly, a significant change is observed in energy transfer mode from the porous bed corresponding to specific values of bed permeability and bed heat generation rate. This is characterised in terms of Ra and Da. Further, it is observed that this change in energy transfer mode is highly dependent on Ra. - Highlights: • Natural convection is analysed in an enclosure with a heat generating porous bed. • Effect of dimensionless parameters as well as bed geometry has been investigated. • Energy transfer mechanism from porous bed changes with dimensionless parameters. • Bed geometry significantly affects fluid flow and energy transfer in the enclosure.

  2. Potential arsenic exposures in 25 species of zoo animals living in CCA-wood enclosures

    International Nuclear Information System (INIS)

    Gress, J.; Silva, E.B. da; Oliveira, L.M. de; Zhao, Di; Anderson, G.; Heard, D.; Stuchal, L.D.; Ma, L.Q.

    2016-01-01

    Animal enclosures are often constructed from wood treated with the pesticide chromated copper arsenate (CCA), which leaches arsenic (As) into adjacent soil during normal weathering. This study evaluated potential pathways of As exposure in 25 species of zoo animals living in CCA-wood enclosures. We analyzed As speciation in complete animal foods, dislodgeable As from CCA-wood, and As levels in enclosure soils, as well as As levels in biomarkers of 9 species of crocodilians (eggs), 4 species of birds (feathers), 1 primate species (hair), and 1 porcupine species (quills). Elevated soil As in samples from 17 enclosures was observed at 1.0–110 mg/kg, and enclosures housing threatened and endangered species had As levels higher than USEPA's risk-based Eco-SSL for birds and mammals of 43 and 46 mg/kg. Wipe samples of CCA-wood on which primates sit had dislodgeable As residues of 4.6–111 μg/100 cm 2 , typical of unsealed CCA-wood. Inorganic As doses from animal foods were estimated at 0.22–7.8 μg/kg bw/d. Some As levels in bird feathers and crocodilian eggs were higher than prior studies on wild species. However, hair from marmosets had 6.37 mg/kg As, 30-fold greater than the reference value, possibly due to their inability to methylate inorganic As. Our data suggested that elevated As in soils and dislodgeable As from CCA-wood could be important sources of As exposure for zoo animals. - Highlights: • Daily inorganic As dose from zoo animal foods was 0.22–7.8 μg/kg bw/day. • Total As concentrations in soils of zoo animal enclosures were 1.0–110 mg/kg. • Endangered zoo animals live in soils with As above USEPA Eco-SSLs for avian and mammal species. • Dislodgeable As on CCA-wood beams where primates sit was 4.6–111 μg/100 cm 2 . • Marmoset hair had 6.37 mg/kg As compared to a reference value of 0.21 mg/kg.

  3. Potential arsenic exposures in 25 species of zoo animals living in CCA-wood enclosures

    Energy Technology Data Exchange (ETDEWEB)

    Gress, J. [State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Jiangsu 201146 (China); Soil and Water Science Department, University of Florida, Gainesville, FL 32611 (United States); Silva, E.B. da; Oliveira, L.M. de [Soil and Water Science Department, University of Florida, Gainesville, FL 32611 (United States); Zhao, Di [State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Jiangsu 201146 (China); Anderson, G. [Virginia Polytechnic Institute and State University, Blacksburg, VA 24061 (United States); Heard, D. [Department of Small Animal Clinical Sciences, University of Florida, Gainesville, FL 32610 (United States); Stuchal, L.D. [Center for Environmental and Human Toxicology, University of Florida, Gainesville, FL 32611 (United States); Department of Environmental and Global Health, College of Public Health and Health Professions, University of Florida, Gainesville, FL 32611 (United States); Ma, L.Q., E-mail: lqma@ufl.edu [State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Jiangsu 201146 (China); Soil and Water Science Department, University of Florida, Gainesville, FL 32611 (United States)

    2016-05-01

    Animal enclosures are often constructed from wood treated with the pesticide chromated copper arsenate (CCA), which leaches arsenic (As) into adjacent soil during normal weathering. This study evaluated potential pathways of As exposure in 25 species of zoo animals living in CCA-wood enclosures. We analyzed As speciation in complete animal foods, dislodgeable As from CCA-wood, and As levels in enclosure soils, as well as As levels in biomarkers of 9 species of crocodilians (eggs), 4 species of birds (feathers), 1 primate species (hair), and 1 porcupine species (quills). Elevated soil As in samples from 17 enclosures was observed at 1.0–110 mg/kg, and enclosures housing threatened and endangered species had As levels higher than USEPA's risk-based Eco-SSL for birds and mammals of 43 and 46 mg/kg. Wipe samples of CCA-wood on which primates sit had dislodgeable As residues of 4.6–111 μg/100 cm{sup 2}, typical of unsealed CCA-wood. Inorganic As doses from animal foods were estimated at 0.22–7.8 μg/kg bw/d. Some As levels in bird feathers and crocodilian eggs were higher than prior studies on wild species. However, hair from marmosets had 6.37 mg/kg As, 30-fold greater than the reference value, possibly due to their inability to methylate inorganic As. Our data suggested that elevated As in soils and dislodgeable As from CCA-wood could be important sources of As exposure for zoo animals. - Highlights: • Daily inorganic As dose from zoo animal foods was 0.22–7.8 μg/kg bw/day. • Total As concentrations in soils of zoo animal enclosures were 1.0–110 mg/kg. • Endangered zoo animals live in soils with As above USEPA Eco-SSLs for avian and mammal species. • Dislodgeable As on CCA-wood beams where primates sit was 4.6–111 μg/100 cm{sup 2}. • Marmoset hair had 6.37 mg/kg As compared to a reference value of 0.21 mg/kg.

  4. Solid Waste Operations Complex W-113, Detail Design Report (Title II). Volume 5: Design validation assessments and lists

    International Nuclear Information System (INIS)

    1995-09-01

    The Solid Waste Retrieval Facility--Phase 1 (Project W113) will provide the infrastructure and the facility required to retrieve from Trench 04, Burial ground 4C, contact handled (CH) drums and boxes at a rate that supports all retrieved TRU waste batching, treatment, storage, and disposal plans. This includes (1) operations related equipment and facilities, viz., a weather enclosure for the trench, retrieval equipment, weighing, venting, obtaining gas samples, overpacking, NDE, NDA, shipment of waste and (2) operations support related facilities, viz., a general office building, a retrieval staff change facility, and infrastructure upgrades such as supply and routing of water, sewer, electrical power, fire protection, roads, and telecommunication. Title I design for the operations related equipment and facilities was performed by Raytheon/BNFL, and that for the operations support related facilities including infrastructure upgrade was performed by KEH. These two scopes were combined into an integrated W113 Title II scope that was performed by Raytheon/BNFL. The following Code Evaluation analyzes the applicable sections of the National Fire Protection Association (NFPA) 101, Life Safety Code, 1994 Edition and the 1994 Edition of the Uniform Building Code (UBC) to the W113 Trench Enclosure. A Building Code Analysis generally establishes four primary design criteria: occupancy classification; separation requirements; egress requirements; and construction type. The UBC establishes requirements for all criteria. This analysis is limited to the Trench Enclosure Building. The General Office Building and the Retrieval Staff Change Building is not within the scope of this analysis

  5. Natural convection of Al2O3-water nanofluid in a wavy enclosure

    Science.gov (United States)

    Leonard, Mitchell; Mozumder, Aloke K.; Mahmud, Shohel; Das, Prodip K.

    2017-06-01

    Natural convection heat transfer and fluid flow inside enclosures filled with fluids, such as air, water or oil, have been extensively analysed for thermal enhancement and optimisation due to their applications in many engineering problems, including solar collectors, electronic cooling, lubrication technologies, food processing and nuclear reactors. In comparison, little effort has been given to the problem of natural convection inside enclosures filled with nanofluids, while the addition of nanoparticles into a fluid base to alter thermal properties can be a feasible solution for many heat transfer problems. In this study, the problem of natural convection heat transfer and fluid flow inside a wavy enclosure filled with Al2O3-water nanofluid is investigated numerically using ANSYS-FLUENT. The effects of surface waviness and aspect ratio of the wavy enclosure on the heat transfer and fluid flow are analysed for various concentrations of Al2O3 nanoparticles in water. Flow fields and temperature fields are investigated and heat transfer rate is examined for different values of Rayleigh number. Results show that heat transfer within the enclosure can be enhanced by increasing surface waviness, aspect ratio or nanoparticles volume fraction. Changes in surface waviness have little effect on the heat transfer rate at low Rayleigh numbers, but when Ra ≥ 105 heat transfer increases with the increase of surface waviness from zero to higher values. Increasing the aspect ratio causes an increase in heat transfer rate, as the Rayleigh number increases the effect of changing aspect ratio is more apparent with the greatest heat transfer enhancement seen at higher Rayleigh numbers. Nanoparticles volume fraction has a little effect on the average Nusselt number at lower Rayleigh numbers when Ra ≥ 105 average Nusselt number increases with the increase of volume fraction. These findings provide insight into the heat transfer effects of using Al2O3-water nanofluid as a heat

  6. The disposal and reparation of radio-active enclosures

    International Nuclear Information System (INIS)

    Boutot, P.

    1964-01-01

    The dismantling of active installations with a view to repairing them or disposing of them is an exceptional operation which tends nevertheless to become more frequent as the materials age technically or mechanically. The author describes, after two years experience, the peculiarities of the method for dismantling which is carried out inside sealed enclosures after the contamination has been fixed. (author) [fr

  7. Multi-criteria analysis for municipal solid waste management in a Brazilian metropolitan area.

    Science.gov (United States)

    Santos, Simone Machado; Silva, Maisa Mendonça; Melo, Renata Maciel; Gavazza, Savia; Florencio, Lourdinha; Kato, Mario T

    2017-10-15

    The decision-making process involved in municipal solid waste management (MSWM) must consider more than just financial aspects, which makes it a difficult task in developing countries. The Recife Metropolitan Region (RMR) in the Northeast of Brazil faces a MSWM problem that has been ongoing since the 1970s, with no common solution. In order to direct short-term solutions, three MSWM alternatives were outlined for the RMR, considering the current and future situations, the time and cost involved and social/environmental criteria. A multi-criteria approach, based on the Preference Ranking Organization Method for Enrichment Evaluations (PROMETHEE), was proposed to rank these alternatives. The alternative that included two private landfill sites and seven transfer, sorting and composting stations was confirmed as the most suitable and stable option for short-term MSWM, considering the two scenarios for the criteria weights. Sensitivity analysis was also performed to support the robustness of the results. The implementation of separate collections would minimize the amount of waste buried, while maximizing the useful life of landfill sites and increasing the timeframe of the alternative. Overall, the multi-criteria analysis was helpful and accurate during the alternative selection process, considering the similarities and restrictions of each option, which can lead to difficulties during the decision-making process.

  8. Some comments on the hydrogen atom in a spherical enclosure

    International Nuclear Information System (INIS)

    Aguilera-Navarro, V.C.; Koo, E.L.; Zimerman, A.H.

    1980-01-01

    Some properties of the ground state energy solutions for the hydrogen atom in a spherical enclosure are discussed. The application of the many-point Pade approximants to this kind of systems inside a box is consider also. (Author) [pt

  9. Transfer of toxic and radioactive materials to and from a work enclosure

    International Nuclear Information System (INIS)

    Hackney, S.

    1980-01-01

    Apparatus for transfer of toxic and radioactive materials between a work enclosure, e.g. a glove box, and a container for storing and transporting the materials comprises a 'double-cover' through which materials are moved. A port in the enclosure is closed by a first cover and the container is closed by a second cover. During transfer, the covers are connected together and the space between the covers is swept by an air stream supplied by a pipe to prevent ingress and deposition of toxic or radioactive material on the facing surfaces of the cover which are subsequently exposed to the environment on separation of the covers. (author)

  10. Natural convection in square enclosure induced by inner circular cylinder with time-periodic pulsating temperature

    KAUST Repository

    Huang, Zhu

    2015-03-01

    The periodic unsteady natural convection flow and heat transfer in a square enclosure containing a concentric circular cylinder is numerically studied. The temperature of the inner circular cylinder fluctuates periodically with time at higher averaged value while the temperature of the enclosure keeps lower constant, and the natural convection is driven by the temperature difference. The two-dimensional natural convection is simulated with high accuracy temporal spectral method and local radial basis functions method. The Rayleigh number is studied in the range 103 ≤ Ra ≤ 106, the temperature pulsating period ranges from 0.01 to 100 and the temperature pulsating amplitudes are a = 0.5, 1.0 and 1.5. Numerical results reveal that the fluid flow and heat transfer is strongly dependent on the pulsating temperature of inner cylinder. Comparing with the steady state natural convection, the heat transfer is enhanced generally for the time-periodic unsteady natural convection, and the local maximum heat transfer rate is observed for Ra = 105 and 106. Moreover, the phenomenon of backward heat transfer is discussed quantitatively. Also, the influence of pulsating temperature on the unsteady fluid flow and heat transfer are discussed and analyzed.

  11. High rabbit abundance proves detrimental to the population growth rate in European rabbit (Oryctolagus cuniculus L. extensive breeding enclosures

    Directory of Open Access Journals (Sweden)

    L. Ruiz-Aizpurua

    2014-09-01

    Full Text Available The European rabbit (Oryctolagus cuniculus L. is a key prey species in Mediterranean ecosystems that has declined in its natural ranges as a result of diseases and loss of habitat. This situation has led to the production of wild rabbits in enclosures in which they can acclimate and breed. The efficiency of these enclosures as extensive breeding systems is defined by their population growth rate (PGR. The aim of this study is to analyse the effect of rabbit abundance on the PGR. This has been done by creating general linear models to explain autumn and spring PGR with the use of rabbit abundance estimates, enclosure size, aerial predation and previous PGR as possible explanatory variables. Rabbit abundance and enclosure size negatively affected the autumn PGR, while only rabbit abundance affected the spring PGR in the best-fit models. It is suggested that maintaining rabbit densities at fewer than 30 rabbits per hectare might help to optimise the efficiency inside enclosures.

  12. A multi-agent architecture for sharing knowledge and experimental data about waste water treatment plants through the Internet

    International Nuclear Information System (INIS)

    Abu Yaman, I. R.; Kerckhoffs, J. E.

    1998-01-01

    In this paper, we present a first prototype of a local multi-agent architecture for the sharing of knowledge and experimental data about waste water treatment plants through the Internet, or more specifically the WWW. Applying a net browser such as nets cape, a user can have access to a CLIPS expert system (advising on waste water cleaning technologies) and experimental data files. The discussed local prototype is part of proposed global agent architecture. (authors)

  13. Multi-functional energy plantation; Multifunktionella bioenergiodlingar

    Energy Technology Data Exchange (ETDEWEB)

    Boerjesson, Paal [Lund Univ. (Sweden). Environmental and Energy Systems Studies; Berndes, Goeran; Fredriksson, Fredrik [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Physical Resource Theory; Kaaberger, Tomas [Ecotraffic, Goeteborg (Sweden)

    2002-02-01

    There exists a significant potential for utilising perennial energy plantations in protecting and restoring polluted water and land resources in Sweden. By optimising the design, location and management, several additional environmental services could be obtained which will increase the value of the energy plantations, thereby improving future market conditions for biomass. Multi-functional energy plantations (mainly Salix but also energy grass) can be divided into two categories, those designed for dedicated environmental services (e.g. vegetation filters for wastewater and sewage sludge treatment and shelter belts against soil erosion), and those generating more general benefits (e.g. soil carbon accumulation, increased soil fertility, cadmium removal and increased hunting potential). The practical potential of those two categories is estimated to be equivalent to up to 3% and more than 20% of the total Swedish arable land, respectively. The regional conditions of utilising multi-functional plantations vary, however, with the best possibilities in densely populated areas dominated by farmland. The economic value of multi-functional plantations is normally highest for those designed for dedicated environmental services. Purification of wastewater has the highest value, which could exceed the production cost in conventional Salix plantations, followed by treatment of polluted drainage water in vegetation filters and buffer zones (equivalent to more than half of the production cost), recirculation of sewage sludge (around half of the production cost), erosion control (around one fourth) and increased hunting potential (up to 15% of the production cost). The value of increased hunting potential varies due to nearness to larger cities and in which part of Sweden the plantation is located. The economic value of cadmium removal and increased soil fertility is equivalent to a few percent of the production cost, but the value of cadmium removal might increase in the

  14. Natural convection heat transfer from a horizontal wavy surface in a porous enclosure

    International Nuclear Information System (INIS)

    Murthy, P.V.S.N.; Kumar, B.V.R.; Singh, P.

    1997-01-01

    The effect of surface undulations on the natural convection heat transfer from an isothermal surface in a Darcian fluid-saturated porous enclosure has been numerically analyzed using the finite element method on a graded nonuniform mesh system. The flow-driving Rayleigh number Ra together with the geometrical parameters of wave amplitude a, wave phase φ, and the number of waves N considered in the horizontal dimension of the cavity are found to influence the flow and heat transfer process in the enclosure. For Ra around 50 and above, the phenomenon of flow separation and reattachment is noticed on the walls of the enclosure. A periodic shift in the reattachment point from the bottom wall to the adjacent walls in the clockwise direction, leading to the manifestation of cycles of unicellular and bicellular clockwise and counterclockwise flows, is observed, with the phase varying between 0 degree and 350 degree. The counterflow in the secondary circulation zone is intensified with the increase in the value of Ra. The counterflow on the wavy wall hinders the heat transfer into the system. An increase in either wave amplitude or the number of waves considered per unit length decreases the global heat flux into the system. Only marginal changes in global heat flux are noticed with increasing Ra. On the whole, the comparison of global heat flux results in the wavy wall case with those of the horizontal flat wall case shows that, in a porous enclosure, the wavy wall reduces the heat transfer into the system

  15. Optimal Waste Load Allocation Using Multi-Objective Optimization and Multi-Criteria Decision Analysis

    Directory of Open Access Journals (Sweden)

    L. Saberi

    2016-10-01

    Full Text Available Introduction: Increasing demand for water, depletion of resources of acceptable quality, and excessive water pollution due to agricultural and industrial developments has caused intensive social and environmental problems all over the world. Given the environmental importance of rivers, complexity and extent of pollution factors and physical, chemical and biological processes in these systems, optimal waste-load allocation in river systems has been given considerable attention in the literature in the past decades. The overall objective of planning and quality management of river systems is to develop and implement a coordinated set of strategies and policies to reduce or allocate of pollution entering the rivers so that the water quality matches by proposing environmental standards with an acceptable reliability. In such matters, often there are several different decision makers with different utilities which lead to conflicts. Methods/Materials: In this research, a conflict resolution framework for optimal waste load allocation in river systems is proposed, considering the total treatment cost and the Biological Oxygen Demand (BOD violation characteristics. There are two decision-makers inclusive waste load discharges coalition and environmentalists who have conflicting objectives. This framework consists of an embedded river water quality simulator, which simulates the transport process including reaction kinetics. The trade-off curve between objectives is obtained using the Multi-objective Particle Swarm Optimization Algorithm which these objectives are minimization of the total cost of treatment and penalties that must be paid by discharges and a violation of water quality standards considering BOD parameter which is controlled by environmentalists. Thus, the basic policy of river’s water quality management is formulated in such a way that the decision-makers are ensured their benefits will be provided as far as possible. By using MOPSO

  16. Multi-Valued Logic Gates, Continuous Sensitivity, Reversibility, and Threshold Functions

    OpenAIRE

    İlhan, Aslı Güçlükan; Ünlü, Özgün

    2016-01-01

    We define an invariant of a multi-valued logic gate by considering the number of certain threshold functions associated with the gate. We call this invariant the continuous sensitivity of the gate. We discuss a method for analysing continuous sensitivity of a multi-valued logic gate by using experimental data about the gate. In particular, we will show that this invariant provides a lower bound for the sensitivity of a boolean function considered as a multi-valued logic gate. We also discuss ...

  17. A location procedure for sound sources in reactor-technical enclosures

    International Nuclear Information System (INIS)

    Hamann, D.

    1982-07-01

    A passive method requiring one detector only has been developed for the location of sound emitting faults in nuclear power plant components. It is adapted for use in a frequency range the wavelength of which is of the same order of magnitude as characteristic dimensions of the considered enclosure. The location is performed in the following way: (1) For a fixed detector position the Auto Power Spectral Density (APSD) of the source to be located is measured. (2) For this detector position the APSD is calculated for the potential source locations. For this, the free-field APSD as well as the acoustic normal modes of the enclosure are necessary. (3) The measured APSD is compared with the theoretically obtained APSD's. (4) That APSD is determined which is most similar to the measured APSD, and consequently an information about the unknown source position is got. (author)

  18. Multi-gene genetic programming based predictive models for municipal solid waste gasification in a fluidized bed gasifier.

    Science.gov (United States)

    Pandey, Daya Shankar; Pan, Indranil; Das, Saptarshi; Leahy, James J; Kwapinski, Witold

    2015-03-01

    A multi-gene genetic programming technique is proposed as a new method to predict syngas yield production and the lower heating value for municipal solid waste gasification in a fluidized bed gasifier. The study shows that the predicted outputs of the municipal solid waste gasification process are in good agreement with the experimental dataset and also generalise well to validation (untrained) data. Published experimental datasets are used for model training and validation purposes. The results show the effectiveness of the genetic programming technique for solving complex nonlinear regression problems. The multi-gene genetic programming are also compared with a single-gene genetic programming model to show the relative merits and demerits of the technique. This study demonstrates that the genetic programming based data-driven modelling strategy can be a good candidate for developing models for other types of fuels as well. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Transportation operations functions of the federal waste management system

    International Nuclear Information System (INIS)

    Shappert, L.B.; Klimas, M.J.

    1989-01-01

    This paper documents the functions that are necessary to operate the OCRWM transportation system. OCRWM's mission is to accept and transport spent fuel and high-level waste from waste generators to FWMS facilities. The emphasis is on transportation operations and assumes that all necessary facilities are in place and equipment designs and specifications are available to permit the system to operate properly. The information reported in this paper was developed for TOPO and is compatible with the draft revision of the Waste Management System Requirements and Description (SRD). 5 refs

  20. Numerical Study of Natural Convection within a Wavy Enclosure Using Meshfree Approach: Effect of Corner Heating

    Directory of Open Access Journals (Sweden)

    Sonam Singh

    2014-01-01

    Full Text Available This paper presents a numerical study of natural convection within a wavy enclosure heated via corner heating. The considered enclosure is a square enclosure with left wavy side wall. The vertical wavy wall of the enclosure and both of the corner heaters are maintained at constant temperature, Tc and Th, respectively, with Th>Tc while the remaining horizontal, bottom, top and side walls are insulated. A penalty element-free Galerkin approach with reduced gauss integration scheme for penalty terms is used to solve momentum and energy equations over the complex domain with wide range of parameters, namely, Rayleigh number (Ra, Prandtl number (Pr, and range of heaters in the x- and y-direction. Numerical results are represented in terms of isotherms, streamlines, and Nusselt number. It is observed that the rate of heat transfer depends to a great extent on the Rayleigh number, Prandtl number, length of the corner heaters and the shape of the heat transfer surface. The consistent performance of the adopted numerical procedure is verified by comparison of the results obtained through the present meshless technique with those existing in the literature.

  1. Heat transfer effects in vertically emplaced high level nuclear waste container

    International Nuclear Information System (INIS)

    Moujaes, S.F.; Lei, Y.M.

    1994-01-01

    Modeling free convection heat transfer in an cylindrical annular enclosure is still an active area of research and an important problem to be addressed in the high level nuclear waste repository. For the vertically emplaced waste container, the air gap which is between the container shell and the rock borehole, have an important role of dissipating heat to surrounding rack. These waste containers are vertically emplaced in the borehole 300 meters below ground, and in a horizontal grid of 30 x 8 meters apart. The borehole will be capped after the container emplacement. The expected initial heat generated is between 3--4.74 kW per container depending on the type of waste. The goal of this study is to use a computer simulation model to find the borehole wall, air-gap and the container outer wall temperature distributions

  2. Approaches for quantifying reactive and low-volatility biogenic organic compound emissions by vegetation enclosure techniques - part A.

    Science.gov (United States)

    Ortega, John; Helmig, Detlev

    2008-06-01

    The high reactivity and low vapor pressure of many biogenic volatile organic compounds (BVOC) make it difficult to measure whole-canopy fluxes of BVOC species using common analytical techniques. The most appropriate approach for estimating these BVOC fluxes is to determine emission rates from dynamic vegetation enclosure measurements. After scaling leaf- and branch-level emission rates to the canopy level, these fluxes can then be used in models to determine BVOC influences on atmospheric chemistry and aerosol processes. Previously published reports from enclosure measurements show considerable variation among procedures with limited guidelines or standard protocols to follow. This article reviews this literature and describes the variety of enclosure types, materials, and analysis techniques that have been used to determine BVOC emission rates. The current review article is followed by a companion paper which details a comprehensive enclosure technique that incorporates both recommendations from the literature as well as insight gained from theoretical calculations and practical experiences. These methods have yielded new BVOC emission data for highly reactive monoterpenes (MT) and sesquiterpenes (SQT) from a variety of vegetation species.

  3. Mixing Processes in High-Level Waste Tanks - Final Report

    International Nuclear Information System (INIS)

    Peterson, P.F.

    1999-01-01

    The mixing processes in large, complex enclosures using one-dimensional differential equations, with transport in free and wall jets is modeled using standard integral techniques. With this goal in mind, we have constructed a simple, computationally efficient numerical tool, the Berkeley Mechanistic Mixing Model, which can be used to predict the transient evolution of fuel and oxygen concentrations in DOE high-level waste tanks following loss of ventilation, and validate the model against a series of experiments

  4. Resistor capacitor, primitive variable solution of buoyant fluid flow within an enclosure with highly temperature dependent viscosity

    Energy Technology Data Exchange (ETDEWEB)

    Burns, S.P. [Texas Univ., Austin, TX (United States); Gianoulakis, S.E. [Sandia National Labs., Albuquerque, NM (United States)

    1995-07-01

    A numerical solution for buoyant natural convection within a square enclosure containing a fluid with highly temperature dependent viscosity is presented. Although the fluid properties employed do not represent any real fluid, the large variation in the fluid viscosity with temperature is characteristic of turbulent flow modeling with eddy-viscosity concepts. Results are obtained using a primitive variable formulation and the resistor method. The results presented include velocity, temperature and pressure distributions within the enclosure as well as shear stress and heat flux distributions along the enclosure walls. Three mesh refinements were employed and uncertainty values are suggested for the final mesh refinement. These solutions are part of a contributed benchmark solution set for the subject problem.

  5. Evaluation of climatic vibration testing on plastic waterproof enclosure for electronic equipment using ANSYS[reg] workbench

    International Nuclear Information System (INIS)

    Aw, K.C.; Huang, W.D.J.; De Silva, M.W.R.P.

    2007-01-01

    Designing and testing of waterproof enclosure for electronic equipment involves significant amount of time and resources. This paper concentrates on electronic equipment used for maritime application. Typical waterproof test perform is based on the IEC 60529 standards and is insufficient to determine its reliability. Since, these enclosures were subjected to environmental stress such as heat and vibration and there is a need to understand how these affect the waterproof performance. Simulation using ANSYS workbench software was performed to comprehend the effect of various parameters of accelerated testing performed on these waterproof enclosures. Experiments were performed to examine the correlation with simulation results. The results confirmed that accelerated testing with random vibration at cold temperature causes greatest stress and causes degradation to adhesive bonds and hence affect the waterproof performance

  6. Analytical Modeling of Natural Convection in a Tall Rectangular Enclosure with Multiple Disconnected Partitions

    Directory of Open Access Journals (Sweden)

    Youngmin Bae

    2016-08-01

    Full Text Available In this study, laminar natural circulation and heat transfer in a tall rectangular enclosure with disconnected vertical partitions inside were investigated. Analytical expressions were developed to predict the circulation flow rate and the average Nusselt number in a partially partitioned enclosure with isothermal side walls at different temperatures and insulated top and bottom walls. The proposed formulas are then validated against numerical results for modified Rayleigh numbers of up to 106. The impacts of the governing parameters are also examined along with a discussion of the heat transfer regimes.

  7. Process and device for leak rate measurement of an enclosure

    International Nuclear Information System (INIS)

    Giroux, J.

    1989-01-01

    The volume of a cavity, such as a cylinder and a piston, connected to the enclosure (glovebox or reactor containment shell) is varied to find back the previous pressure difference with the outside (positive or negative). Thermometers and a barometer are provided for eventual corrections [fr

  8. Defining criteria related to wastes for use in multi-criteria decision tool for nuclear accidents

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Diogo N.G.; Guimaraes, Jean R.D., E-mail: dneves@biof.ufrj.br, E-mail: jeanrdg@biof.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Instituto de Biofisica Carlos Chagas Filho; Rochedo, Elaine R.R.; De Luca, Christiano, E-mail: elainerochedo@gmail.com, E-mail: christiano_luca@hotmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Rochedo, Pedro R.R., E-mail: rochedopedro@gmail.com [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Instituto Alberto Luiz Coimbra de Pos-Graduacao e Pesquisa de Engenharia

    2013-07-01

    The selection of protective measures and strategies for remediation of contaminated areas after a nuclear accident must be based on previously established criteria in order to prevent stress of the population and the unnecessary exposure of workers. After a nuclear accident resulting in environmental contamination, decisions on remediation of areas is complex due to the large numbers of factors involved in decontamination processes. This work is part of a project which aims to develop a multi-criteria tool to support a decision-making process in cases of a radiological or a nuclear accident in Brazil. First, a database of remediation strategies for contaminated areas was created. In this process, the most relevant aspects for the implementation of these strategies were considered, including technical criteria regarding aspects related to the generation of wastes in a reference urban area, which are discussed in this paper. The specific objective of this study is to define criteria for the aspects of radioactive wastes, resulted by the implementation of some urban measures, in order to be incorporated in a multi-criteria decision tool. Main aspects considered were the type, the amount and the type of treatment necessary for each procedure. The decontamination procedures are then classified according to the selected criteria in order to feed the multi-criteria decision tool. This paper describes the steps for the establishment of these criteria and evaluates the potential for future applications in order to improve predictions and to support the decisions to be made. (author)

  9. Defining criteria related to wastes for use in multi-criteria decision tool for nuclear accidents

    International Nuclear Information System (INIS)

    Silva, Diogo N.G.; Guimaraes, Jean R.D.; Rochedo, Elaine R.R.; De Luca, Christiano; Rochedo, Pedro R.R.

    2013-01-01

    The selection of protective measures and strategies for remediation of contaminated areas after a nuclear accident must be based on previously established criteria in order to prevent stress of the population and the unnecessary exposure of workers. After a nuclear accident resulting in environmental contamination, decisions on remediation of areas is complex due to the large numbers of factors involved in decontamination processes. This work is part of a project which aims to develop a multi-criteria tool to support a decision-making process in cases of a radiological or a nuclear accident in Brazil. First, a database of remediation strategies for contaminated areas was created. In this process, the most relevant aspects for the implementation of these strategies were considered, including technical criteria regarding aspects related to the generation of wastes in a reference urban area, which are discussed in this paper. The specific objective of this study is to define criteria for the aspects of radioactive wastes, resulted by the implementation of some urban measures, in order to be incorporated in a multi-criteria decision tool. Main aspects considered were the type, the amount and the type of treatment necessary for each procedure. The decontamination procedures are then classified according to the selected criteria in order to feed the multi-criteria decision tool. This paper describes the steps for the establishment of these criteria and evaluates the potential for future applications in order to improve predictions and to support the decisions to be made. (author)

  10. Conjugate transient natural convection in a cylindrical enclosure with internal volumetric heat generation

    International Nuclear Information System (INIS)

    Sharma, Anil Kumar; Velusamy, K.; Balaji, C.

    2008-01-01

    This paper reports the results of a numerical investigation of transient turbulent natural convection heat transfer from a volumetric energy generating source placed inside a cylindrical enclosure filled with low Prandtl number fluid (liquid sodium, Pr = 0.005). Two-dimensional conservation equations of mass, momentum and energy, coupled with the Boussinesq approximation, are solved using a finite volume based discretisation method employing the SIMPLE algorithm for the pressure velocity coupling. Turbulence is modeled using the k-ε model with physical boundary conditions. The study presents the transient features of confined turbulent natural convection, due to time varying generation of heat in the volumetric source. The intensity of heat source exponentially decays with time and the source is placed over circular plates with a central opening. Results obtained from the numerical model compare favorably with those reported in the literature for steady state natural convection. Numerical simulations are carried out to display the sequential evolution of flow and thermal fields and the maximum temperature reached in the source. The advantages of distributing the heat source on multi trays have been quantified

  11. Multi-level governance-perspective on management of nuclear waste disposal. A comparative analysis

    Energy Technology Data Exchange (ETDEWEB)

    Brunnengraeber, Achim; Haefner, Daniel

    2015-07-01

    The primary aim of the project is to conduct a detailed social and political analysis of the preconditions for the development of an acceptable strategy for nuclear waste disposal in Germany. This includes the identification of stakeholders and their interests, responsibilities, value systems, views and expectations as well as paths for a constructive approach to dialogue and problem-solving. A focus of the research project will be an international comparative multi-level governance analysis of acceptance patterns and steering mechanisms for conflict resolution.

  12. Multi-level governance-perspective on management of nuclear waste disposal. A comparative analysis

    International Nuclear Information System (INIS)

    Brunnengraeber, Achim; Haefner, Daniel

    2015-01-01

    The primary aim of the project is to conduct a detailed social and political analysis of the preconditions for the development of an acceptable strategy for nuclear waste disposal in Germany. This includes the identification of stakeholders and their interests, responsibilities, value systems, views and expectations as well as paths for a constructive approach to dialogue and problem-solving. A focus of the research project will be an international comparative multi-level governance analysis of acceptance patterns and steering mechanisms for conflict resolution.

  13. Shielded enclosure for handling radioactive material; Sorbonnes blindees pour manipulations radioactives

    Energy Technology Data Exchange (ETDEWEB)

    Laurent, H; Courouble, J M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-07-01

    Two enclosures linked by an air-lock are described: they are designed for the safe handling of 5 curies 0.3 to 0.5 MeV {gamma} emitters, and each is composed of a semi-tight case, ventilated, clad in 80 mm steel plate, and suited for a wide variety of physics and chemistry operations. The equipment required for any given operation can be installed in the shortest possible time, access to the enclosure being via a removable front. Visual control is assured through a lead-glass screen. Each enclosure is fitted with a master-slave manipulator, Argon model 7, and plugs and air-locks are provided for the introduction of liquids and solids. (author) [French] On decrit deux enceintes reliees par un sas pour manipulation sur 5 curies d'emetteurs {gamma} de 0,3 a 0,5 MeV. Chacune des enceintes est constituee d'une boite semi-etanche, ventilee, entouree de toles d'acier de 80 mm. L'ensemble est concu pour y effectuer les operations physiques ou chimiques les plus variees. L'equipement necessaire a une manipulation donnee peut y etre installe dans le minimum de temps, l'acces se faisant par la face avant qui peut se deplacer. Une dalle de verre au plomb assure la vision. Chacune des sorbonnes est equipee d'une paire de telemanipulateurs Argonne modele 7. Des sas et des bouchons assurent le passage des solides et des fluides. (auteur)

  14. Effectiveness of pads and enclosures as safety interventions on consumer trampolines

    Science.gov (United States)

    Eager, David; Scarrott, Carl; Sushinsky, George

    2010-01-01

    Background Trampolines continue to be a major source of childhood injury. Objective To examine available data on trampoline injuries in order to determine the effectiveness of padding and enclosures. Design Trampoline injuries from the NEISS database from 2002 to 2007 were reclassified into five cause-categories, to examine evidence for injury trends. Setting The ASTM trampoline standard recommendations for safety padding were upgraded in 1999 and enclosures were introduced in 1997. This is the first study to examine the impact of these changes. Patients The sampling frame comprises patients with NEISS product code ‘consumer trampolines’ (1233). A systematic sample of 360 patients each year is taken. Interventions The prominent interventions recommended by the ASTM are netting enclosures to prevent falling off and safety padding to cover frames and springs. Main outcome measures Proportion of injuries within each cause-category and trend estimates. Results There was no evidence for a decline within the injury cause-categories that should be prevented by these interventions from 2002 to 2007. Conclusions If these interventions were effective the associated injury causes would be in decline. Instead they remain close to half of all trampoline injuries with no significant change over the period of the study. Follow-up studies are proposed to determine the reasons. Given the number of injuries involved it is recommended that steps be taken to ensure these safety interventions or their equivalents are in place, work properly and remain effective for the life of consumer trampolines. PMID:20570986

  15. Enhancing monochromatic multipole emission by a subwavelength enclosure of degenerate Mie resonances

    KAUST Repository

    Zhao, Jiajun; Zhang, Likun; Wu, Ying

    2017-01-01

    of the enclosure, and meanwhile the radiation directivity pattern is well preserved. The degeneracy is theoretically analyzed. A realization of the material is suggested by using a space-coiling structure.

  16. Multi-objective optimization of two alkali catalyzed processes for biodiesel from waste cooking oil

    International Nuclear Information System (INIS)

    Patle, Dipesh S.; Sharma, Shivom; Ahmad, Z.; Rangaiah, G.P.

    2014-01-01

    Highlights: • Biodiesel processes use waste cooking oil and are close to industrial practice. • Detailed constituents of waste cooking oil and detailed kinetics are used. • Two complete processes are optimized for economic and environmental objectives. • Obtained trade-offs provide deeper understanding and alternative optimal solutions. - Abstract: In view of the finite availability and environmental concerns of fossil fuels, biodiesel is one of the promising fuel alternatives. This study considers waste cooking palm oil with 6% free fatty acids (FFA) as feed-stock, which facilitates its better utilization and promotes sustainability. Two biodiesel production processes (both involving esterification catalyzed by sulfuric acid and trans-esterification catalyzed by sodium hydroxide) are compared for economic and environmental objectives. Firstly, these processes are simulated, considering detailed constituents of palm oil and also detailed kinetics for both esterification and trans-esterification, in Aspen Plus simulator. Subsequently, both the processes are optimized considering profit, heat duty and organic waste as objectives, and using an Excel-based multi-objective optimization (EMOO) program for the elitist non-dominated sorting genetic algorithm-II (NSGA-II). The results show that the profit improves with the increase in heat duty, and that the profit increase is accompanied by larger amount of organic waste. Process 1 having three trans-esterification reactors produces significantly lower organic waste (by 32%), requires lower heat duty (by 39%) and slightly more profitable (by 1.6%) compared to Process 2 having a single trans-esterification reactor and also a different separation sequence. Overall, the obtained quantitative trade-offs between objectives enable better decision making about the process design for biodiesel production from waste cooking oil

  17. Minimally processed beetroot waste as an alternative source to obtain functional ingredients.

    Science.gov (United States)

    Costa, Anne Porto Dalla; Hermes, Vanessa Stahl; Rios, Alessandro de Oliveira; Flôres, Simone Hickmann

    2017-06-01

    Large amounts of waste are generated by the minimally processed vegetables industry, such as those from beetroot processing. The aim of this study was to determine the best method to obtain flour from minimally processed beetroot waste dried at different temperatures, besides producing a colorant from such waste and assessing its stability along 45 days. Beetroot waste dried at 70 °C originates flour with significant antioxidant activity and higher betalain content than flour produced from waste dried at 60 and 80 °C, while chlorination had no impact on the process since microbiological results were consistent for its application. The colorant obtained from beetroot waste showed color stability for 20 days and potential antioxidant activity over the analysis period, thus it can be used as a functional additive to improve nutritional characteristics and appearance of food products. These results are promising since minimally processed beetroot waste can be used as an alternative source of natural and functional ingredients with high antioxidant activity and betalain content.

  18. Development of enclosure technique of tag gas for in-pile creep test

    International Nuclear Information System (INIS)

    Izaki, Toru; Ichikawa, Shoichi; Soroi, Masatoshi; Ito, Chikara

    2004-01-01

    Outline of the enclosure technique of tag gas for in-pile creep test is stated. In order to carry out in-pile creep test, the sample can enclose tag gas before the test and then the sample is inserted into MARICO-2 (Material Testing Rig with Temperature Control) in FBR 'JOYO' MK-III for the irradiation test. Outline of in-pile creep test using tag gas, enclosure system of tag gas, detection of a part of broken sample and identification of sample are explained. 126-, 128-, 129-, 131-, 132-, and 134-Xe are used as tag gases. The samples are identified by RIMS (Laser Resonance Ionization Mass Spectroscopy) in ppt order. ODS ferritic steel will be tested by the method in the next step. (S.Y.)

  19. Tridentine enclosure gaps. Controversies and Limitations of Policies for Nuns…Still with Felipe IV

    Directory of Open Access Journals (Sweden)

    Ángela Atienza López

    2014-12-01

    Full Text Available The Council of Trent ordered that the strict enclosure for nuns should be carried out. The aim of this paper is to contribute to the analysis of those provisions, pointing out that such monastic discipline had a highly questionable success. The process was full of problems. Even one century after Trent, King Felipe IV still cried out to the situation and deployed a political offensive to reach its imposition. The study of these sources allows us to show the Trent enclosure gaps: how the lack of consent was spread even among the elites of secular and ecclesiastical power, and it hampered its implementation; also how the reality of monastic vows and convent life imposed limits hindering its success; how nuns refused and got support from different sectors; and, on the end, how daily practice of enclosure ran through other channels, where stringency rules could be reconsidered in time and place and could meet their arrangements, more or less lenient, and could be negotiated and renegotiated in everyday life, so that strains could be overcome.

  20. Automatic single- and multi-label enzymatic function prediction by machine learning

    Directory of Open Access Journals (Sweden)

    Shervine Amidi

    2017-03-01

    Full Text Available The number of protein structures in the PDB database has been increasing more than 15-fold since 1999. The creation of computational models predicting enzymatic function is of major importance since such models provide the means to better understand the behavior of newly discovered enzymes when catalyzing chemical reactions. Until now, single-label classification has been widely performed for predicting enzymatic function limiting the application to enzymes performing unique reactions and introducing errors when multi-functional enzymes are examined. Indeed, some enzymes may be performing different reactions and can hence be directly associated with multiple enzymatic functions. In the present work, we propose a multi-label enzymatic function classification scheme that combines structural and amino acid sequence information. We investigate two fusion approaches (in the feature level and decision level and assess the methodology for general enzymatic function prediction indicated by the first digit of the enzyme commission (EC code (six main classes on 40,034 enzymes from the PDB database. The proposed single-label and multi-label models predict correctly the actual functional activities in 97.8% and 95.5% (based on Hamming-loss of the cases, respectively. Also the multi-label model predicts all possible enzymatic reactions in 85.4% of the multi-labeled enzymes when the number of reactions is unknown. Code and datasets are available at https://figshare.com/s/a63e0bafa9b71fc7cbd7.

  1. Multi-criteria evaluation in strategic environmental assessment for waste management plan, a case study: The city of Belgrade

    International Nuclear Information System (INIS)

    Josimović, Boško; Marić, Igor; Milijić, Saša

    2015-01-01

    Highlights: • The paper deals with the specific method of multi-criteria evaluation applied in drafting the SEA for the Belgrade WMP. • MCE of the planning solutions, assessed according to 37 objectives of the SEA and four sets of criteria, was presented in the matrix form. • The results are presented in the form of graphs so as to be easily comprehensible to all the participants in the decision-making process. • The results represent concrete contribution proven in practice. - Abstract: Strategic Environmental Assessment (SEA) is one of the key instruments for implementing sustainable development strategies in planning in general; in addition to being used in sectoral planning, it can also be used in other areas such as waste management planning. SEA in waste management planning has become a tool for considering the benefits and consequences of the proposed changes in space, also taking into account the capacity of space to sustain the implementation of the planned activities. In order to envisage both the positive and negative implications of a waste management plan for the elements of sustainable development, an adequate methodological approach to evaluating the potential impacts must be adopted and the evaluation results presented in a simple and clear way, so as to allow planners to make relevant decisions as a precondition for the sustainability of the activities planned in the waste management sector. This paper examines the multi-criteria evaluation method for carrying out an SEA for the Waste Management Plan for the city of Belgrade (BWMP). The method was applied to the evaluation of the impacts of the activities planned in the waste management sector on the basis of the environmental and socioeconomic indicators of sustainability, taking into consideration the intensity, spatial extent, probability and frequency of impact, by means of a specific planning approach and simple and clear presentation of the obtained results

  2. Multi-criteria evaluation in strategic environmental assessment for waste management plan, a case study: The city of Belgrade

    Energy Technology Data Exchange (ETDEWEB)

    Josimović, Boško, E-mail: bosko@iaus.ac.rs; Marić, Igor; Milijić, Saša

    2015-02-15

    Highlights: • The paper deals with the specific method of multi-criteria evaluation applied in drafting the SEA for the Belgrade WMP. • MCE of the planning solutions, assessed according to 37 objectives of the SEA and four sets of criteria, was presented in the matrix form. • The results are presented in the form of graphs so as to be easily comprehensible to all the participants in the decision-making process. • The results represent concrete contribution proven in practice. - Abstract: Strategic Environmental Assessment (SEA) is one of the key instruments for implementing sustainable development strategies in planning in general; in addition to being used in sectoral planning, it can also be used in other areas such as waste management planning. SEA in waste management planning has become a tool for considering the benefits and consequences of the proposed changes in space, also taking into account the capacity of space to sustain the implementation of the planned activities. In order to envisage both the positive and negative implications of a waste management plan for the elements of sustainable development, an adequate methodological approach to evaluating the potential impacts must be adopted and the evaluation results presented in a simple and clear way, so as to allow planners to make relevant decisions as a precondition for the sustainability of the activities planned in the waste management sector. This paper examines the multi-criteria evaluation method for carrying out an SEA for the Waste Management Plan for the city of Belgrade (BWMP). The method was applied to the evaluation of the impacts of the activities planned in the waste management sector on the basis of the environmental and socioeconomic indicators of sustainability, taking into consideration the intensity, spatial extent, probability and frequency of impact, by means of a specific planning approach and simple and clear presentation of the obtained results.

  3. Public meetings on nuclear waste management: their function and organization

    Energy Technology Data Exchange (ETDEWEB)

    Duvernoy, E.G.; Marcus, A.A.; Overcast, T.; Schilling, A.H.

    1981-05-01

    This report focuses on public meetings as a vehicle for public participation in nuclear waste management. The nature of public meetings is reviewed and the functions served by meetings highlighted. The range of participants and their concerns are addressed, including a review of the participants from past nuclear waste management meetings. A sound understanding of the expected participants allows DOE to tailor elements of the meeting, such as notification, format, and agenda to accommodate the attendees. Finally, the report discusses the organization of public meetings on nuclear waste management in order to enhance the DOE's functions for such meetings. Possible structures are suggested for a variety of elements that are relevant prior to, during and after the public meeting. These suggestions are intended to supplement the DOE Public Participation Manual.

  4. Public meetings on nuclear waste management: their function and organization

    International Nuclear Information System (INIS)

    Duvernoy, E.G.; Marcus, A.A.; Overcast, T.; Schilling, A.H.

    1981-05-01

    This report focuses on public meetings as a vehicle for public participation in nuclear waste management. The nature of public meetings is reviewed and the functions served by meetings highlighted. The range of participants and their concerns are addressed, including a review of the participants from past nuclear waste management meetings. A sound understanding of the expected participants allows DOE to tailor elements of the meeting, such as notification, format, and agenda to accommodate the attendees. Finally, the report discusses the organization of public meetings on nuclear waste management in order to enhance the DOE's functions for such meetings. Possible structures are suggested for a variety of elements that are relevant prior to, during and after the public meeting. These suggestions are intended to supplement the DOE Public Participation Manual

  5. A DGTD Scheme for Modeling the Radiated Emission From DUTs in Shielding Enclosures Using Near Electric Field Only

    KAUST Repository

    Li, Ping

    2016-01-13

    To meet the electromagnetic interference regulation, the radiated emission from device under test such as electronic devices must be carefully manipulated and accurately characterized. Instead of resorting to the direct far-field measurement, in this paper, a novel approach is proposed to model the radiated emission from electronic devices placed in shielding enclosures by using the near electric field only. Based on the Schelkkunoff’s equivalence principle and Raleigh–Carson reciprocity theorem, only the tangential components of the electric field over the ventilation slots and apertures of the shielding enclosure are sufficient to obtain the radiated emissions outside the shielding box if the inside of the shielding enclosure was filled with perfectly electric conductor (PEC). In order to efficiently model wideband emission, the time-domain sampling scheme is employed. Due to the lack of analytical Green’s function for arbitrary PEC boxes, the radiated emission must be obtained via the full-wave numerical methods by considering the total radiated emission as the superposition between the direct radiation from the equivalent magnetic currents in free space and the scattered field generated by the PEC shielding box. In this study, the state-of-the-art discontinuous Galerkin time-domain (DGTD) method is utilized, which has the flexibility to model irregular geometries, keep high-order accuracy, and more importantly involves only local operations. For open-region problems, a hybridized DGTD and time-domain boundary integration method applied to rigorously truncate the computational domain. To validate the proposed approach, several representative examples are presented and compared with both analytical and numerical results.

  6. Functional specifications for a radioactive waste decision support system

    International Nuclear Information System (INIS)

    Westrom, G.B.; Kurrasch, E.R.; Carlton, R.E.; Vance, J.N.

    1989-09-01

    It is generally recognized that decisions relative to the treatment, handling, transportation and disposal of low-level wastes produced in nuclear power plants involve a complex array of many inter-related elements or considerations. Complex decision processes can be aided through the use of computer-based expert systems which are based on the knowledge of experts and the inferencing of that knowledge to provide advice to an end-user. To determine the feasibility of developing and applying an expert system in nuclear plant low level waste operations, a Functional Specification for a Radwaste Decision Support System (RDSS) was developed. All areas of radwaste management, from the point of waste generation to the disposition of the waste in the final disposal location were considered for inclusion within the scope of the RDSS. 27 figs., 8 tabs

  7. Distribution of quantum states in enclosures of finite size I

    International Nuclear Information System (INIS)

    Souto, J.H.; Chaba, A.N.

    1989-01-01

    The expression for the density of states of a particle in a three-dimensional rectangular box of finite size can be obtained directly by Poissons's Summation formula. The expression for the case of an enclosure in the form of an infinite rectangular slab is derived. (A.C.A.S.) [pt

  8. Analysis of Multi-Criteria Evaluation Method of Landfill Site Selection for Municipal Solid Waste Management

    Science.gov (United States)

    Mohammed, Habiba Ibrahim; Majid, Zulkepli; Yusof, Norhakim Bin; Bello Yamusa, Yamusa

    2018-03-01

    Landfilling remains the most common systematic technique of solid waste disposal in most of the developed and developing countries. Finding a suitable site for landfill is a very challenging task. Landfill site selection process aims to provide suitable areas that will protect the environment and public health from pollution and hazards. Therefore, various factors such as environmental, physical, socio-economic, and geological criteria must be considered before siting any landfill. This makes the site selection process vigorous and tedious because it involves the processing of large amount of spatial data, rules and regulations from different agencies and also policy from decision makers. This allows the incorporation of conflicting objectives and decision maker preferences into spatial decision models. This paper particularly analyzes the multi-criteria evaluation (MCE) method of landfill site selection for solid waste management by means of literature reviews and surveys. The study will help the decision makers and waste management authorities to choose the most effective method when considering landfill site selection.

  9. Analysis of Multi-Criteria Evaluation Method of Landfill Site Selection for Municipal Solid Waste Management

    Directory of Open Access Journals (Sweden)

    Ibrahim Mohammed Habiba

    2018-01-01

    Full Text Available Landfilling remains the most common systematic technique of solid waste disposal in most of the developed and developing countries. Finding a suitable site for landfill is a very challenging task. Landfill site selection process aims to provide suitable areas that will protect the environment and public health from pollution and hazards. Therefore, various factors such as environmental, physical, socio-economic, and geological criteria must be considered before siting any landfill. This makes the site selection process vigorous and tedious because it involves the processing of large amount of spatial data, rules and regulations from different agencies and also policy from decision makers. This allows the incorporation of conflicting objectives and decision maker preferences into spatial decision models. This paper particularly analyzes the multi-criteria evaluation (MCE method of landfill site selection for solid waste management by means of literature reviews and surveys. The study will help the decision makers and waste management authorities to choose the most effective method when considering landfill site selection.

  10. Effect of objective function on multi-objective inverse planning of radiation therapy

    International Nuclear Information System (INIS)

    Li Guoli; Wu Yican; Song Gang; Wang Shifang

    2006-01-01

    There are two kinds of objective functions in radiotherapy inverse planning: dose distribution-based and Dose-Volume Histogram (DVH)-based functions. The treatment planning in our days is still a trial and error process because the multi-objective problem is solved by transforming it into a single objective problem using a specific set of weights for each object. This work investigates the problem of objective function setting based on Pareto multi-optimization theory, and compares the effect on multi-objective inverse planning of those two kinds of objective functions including calculation time, converge speed, etc. The basis of objective function setting on inverse planning is discussed. (authors)

  11. Multi- and trans-disciplinarity in radioactive waste disposal. Fundamentals - examples - knowledge synthesis; Inter- und Transdisziplinaritaet bei der Entsorgung radioaktiver Reststoffe. Grundlagen - Beispiele - Wissenssynthese

    Energy Technology Data Exchange (ETDEWEB)

    Smeddinck, Ulrich [Technische Univ. Braunschweig (Germany). Inst. fuer Rechtswissenschaften; Kuppler, Sophie [Karlsruher Institut fuer Technologie (KIT), Karlsruhe (Germany). Inst. fuer Technikfolgenabschaetzung und Systemanalyse (ITAS); Chaudry, Saleem (ed.) [Technische Univ. Clausthal, Clausthal-Zellerfeld (Germany). Inst. fuer Endlagerforschung

    2016-07-01

    The report covers the following issues: radioactive waste disposal - a multi- in trans- disciplinary challenge; political science and nuclear waste governance; interdisciplinary analysis of the radioactive waste disposal concepts - geochemistry bases analyses; radioactive waste disposal and robust jurisprudence; the contribution of geology to the underground storage of radioactive waste; ionizing radiation protection - interdisciplinary points; risk evaluation; possibilities and constraints of a standardization of scientific terms for interdisciplinary cooperation, safety case and interdisciplinarity; the concept of voluntariness in relation with site final repository selection a philosophical und juridical view; interdisciplinarity - engineers and philosophers; knowledge strategies on the way to radioactive waste disposal: scientific synthesis on radioactive waste disposal on the science platform ENTRIA.

  12. Multi-Functional Fibre-Optic Microwave Links

    DEFF Research Database (Denmark)

    Gliese, Ulrik Bo

    1998-01-01

    The multi-functionality of microwave links based on remote heterodyne detection of signals from a dual-frequency laser transmitter is discussed and experimentally demonstrated in this paper. Typically, direct detection in conjunction with optical intensity modulation is used to implement fibre......-optic microwave links. The resulting links are inherently transparent and mainly used for signal transmission. As opposed to direct detection links, remote heterodyne detection links can directly perform functionalities such as modulation, frequency conversion, and transparent signal recovery in addition...

  13. Comparison of multi-enzyme and thermophilic bacteria on the hydrolysis of mariculture organic waste (MOW).

    Science.gov (United States)

    Guo, Liang; Sun, Mei; Zong, Yan; Zhao, Yangguo; Gao, Mengchun; She, Zonglian

    2016-01-01

    Mariculture organic waste (MOW) is rich in organic matter, which is a potential energy resource for anaerobic digestion. In order to enhance the anaerobic fermentation, the MOW was hydrolyzed by multi-enzyme and thermophilic bacteria. It was advantageous for soluble chemical oxygen demand (SCOD) release at MOW concentrations of 6 and 10 g/L with multi-enzyme and thermophilic bacteria pretreatments. For multi-enzyme, the hydrolysis was not obvious at substrate concentrations of 1 and 3 g/L, and the protein and carbohydrate increased with hydrolysis time at substrate concentrations of 6 and 10 g/L. For thermophilic bacteria, the carbohydrate was first released at 2-4 h and then consumed, and the protein increased with hydrolysis time. The optimal enzyme hydrolysis for MOW was determined by measuring the changes of SCOD, protein, carbohydrate, ammonia and total phosphorus, and comparing with acid and alkaline pretreatments.

  14. Performance of Multi-chaotic PSO on a shifted benchmark functions set

    Energy Technology Data Exchange (ETDEWEB)

    Pluhacek, Michal; Senkerik, Roman; Zelinka, Ivan [Tomas Bata University in Zlín, Faculty of Applied Informatics Department of Informatics and Artificial Intelligence nám. T.G. Masaryka 5555, 760 01 Zlín (Czech Republic)

    2015-03-10

    In this paper the performance of Multi-chaotic PSO algorithm is investigated using two shifted benchmark functions. The purpose of shifted benchmark functions is to simulate the time-variant real-world problems. The results of chaotic PSO are compared with canonical version of the algorithm. It is concluded that using the multi-chaotic approach can lead to better results in optimization of shifted functions.

  15. Performance of Multi-chaotic PSO on a shifted benchmark functions set

    International Nuclear Information System (INIS)

    Pluhacek, Michal; Senkerik, Roman; Zelinka, Ivan

    2015-01-01

    In this paper the performance of Multi-chaotic PSO algorithm is investigated using two shifted benchmark functions. The purpose of shifted benchmark functions is to simulate the time-variant real-world problems. The results of chaotic PSO are compared with canonical version of the algorithm. It is concluded that using the multi-chaotic approach can lead to better results in optimization of shifted functions

  16. Melting of nanoparticles-enhanced phase change material (NEPCM) in vertical semicircle enclosure: numerical study

    Energy Technology Data Exchange (ETDEWEB)

    Jourabian, Mahmoud [University of Trieste, Piazzale (Italy); Farhadi, Mousa [Babol Noshirvani University of Technology, Shariati Avenue (Iran, Islamic Republic of)

    2015-09-15

    Convection melting of ice as a Phase change material (PCM) dispersed with Cu nanoparticles, which is encapsulated in a semicircle enclosure is studied numerically. The enthalpy-based Lattice Boltzmann method (LBM) combined with a Double distribution function (DDF) model is used to solve the convection-diffusion equation. The increase in solid concentration of nanoparticles results in the enhancement of thermal conductivity of PCM and the decrease in the latent heat of fusion. By enhancing solid concentration of nanoparticles, the viscosity of nanofluid increases and convective heat transfer dwindles. For all Rayleigh numbers investigated in this study, the insertion of nanoparticles in PCM has no effect on the average Nusselt number.

  17. Melting of nanoparticles-enhanced phase change material (NEPCM) in vertical semicircle enclosure: numerical study

    International Nuclear Information System (INIS)

    Jourabian, Mahmoud; Farhadi, Mousa

    2015-01-01

    Convection melting of ice as a Phase change material (PCM) dispersed with Cu nanoparticles, which is encapsulated in a semicircle enclosure is studied numerically. The enthalpy-based Lattice Boltzmann method (LBM) combined with a Double distribution function (DDF) model is used to solve the convection-diffusion equation. The increase in solid concentration of nanoparticles results in the enhancement of thermal conductivity of PCM and the decrease in the latent heat of fusion. By enhancing solid concentration of nanoparticles, the viscosity of nanofluid increases and convective heat transfer dwindles. For all Rayleigh numbers investigated in this study, the insertion of nanoparticles in PCM has no effect on the average Nusselt number.

  18. Turbulence modeling of natural convection in enclosures: A review

    International Nuclear Information System (INIS)

    Choi, Seok Ki; Kim, Seong O

    2012-01-01

    In this paper a review of recent developments of turbulence models for natural convection in enclosures is presented. The emphasis is placed on the effect of the treatments of Reynolds stress and turbulent heat flux on the stability and accuracy of the solution for natural convection in enclosures. The turbulence models considered in the preset study are the two-layer k -ε model, the shear stress transport (SST) model, the elliptic-relaxation (V2-f) model and the elliptic-blending second-moment closure (EBM). Three different treatments of the turbulent heat flux are the generalized gradient diffusion hypothesis (GGDH), the algebraic flux model (AFM) and the differential flux model (DFM). The mathematical formulation of the above turbulence models and their solution method are presented. Evaluation of turbulence models are performed for turbulent natural convection in a 1:5 rectangular cavity ( Ra = 4.3x10 10 ) and in a square cavity with conducting top and bottom walls ( Ra =1.58x10 9 ) and the Rayleigh-Benard convection ( Ra = 2x10 6 ∼ Ra =10 9 ). The relative performances of turbulence models are examined and their successes and shortcomings are addressed

  19. Magnetometric prospection of various types of large ditched enclosures in Bohemia

    Czech Academy of Sciences Publication Activity Database

    Křivánek, Roman

    2006-01-01

    Roč. 13, č. 1 (2006), s. 25-43 ISSN 1075-2196 R&D Projects: GA ČR GV404/97/K024 Institutional research plan: CEZ:AV0Z80020508 Keywords : prospection * ditch enclosure * magnetometer Subject RIV: AC - Archeology, Anthropology, Ethnology

  20. Integrating multi-criteria decision analysis for a GIS-based hazardous waste landfill sitting in Kurdistan Province, western Iran

    International Nuclear Information System (INIS)

    Sharifi, Mozafar; Hadidi, Mosslem; Vessali, Elahe; Mosstafakhani, Parasto; Taheri, Kamal; Shahoie, Saber; Khodamoradpour, Mehran

    2009-01-01

    The evaluation of a hazardous waste disposal site is a complicated process because it requires data from diverse social and environmental fields. These data often involve processing of a significant amount of spatial information which can be used by GIS as an important tool for land use suitability analysis. This paper presents a multi-criteria decision analysis alongside with a geospatial analysis for the selection of hazardous waste landfill sites in Kurdistan Province, western Iran. The study employs a two-stage analysis to provide a spatial decision support system for hazardous waste management in a typically under developed region. The purpose of GIS was to perform an initial screening process to eliminate unsuitable land followed by utilization of a multi-criteria decision analysis (MCDA) to identify the most suitable sites using the information provided by the regional experts with reference to new chosen criteria. Using 21 exclusionary criteria, as input layers, masked maps were prepared. Creating various intermediate or analysis map layers a final overlay map was obtained representing areas for hazardous waste landfill sites. In order to evaluate different landfill sites produced by the overlaying a landfill suitability index system was developed representing cumulative effects of relative importance (weights) and suitability values of 14 non-exclusionary criteria including several criteria resulting from field observation. Using this suitability index 15 different sites were visited and based on the numerical evaluation provided by MCDA most suitable sites were determined.

  1. Safety of stationary grinding machines - impact resistance of work zone enclosures.

    Science.gov (United States)

    Mewes, Detlef; Adler, Christian

    2017-09-01

    Guards on machine tools are intended to protect persons from being injured by parts ejected with high kinetic energy from the work zone of the machine. Stationary grinding machines are a typical example. Generally such machines are provided with abrasive product guards closely enveloping the grinding wheel. However, many machining tasks do not allow the use of abrasive product guards. In such cases, the work zone enclosure has to be dimensioned so that, in case of failure, grinding wheel fragments remain inside the machine's working zone. To obtain data for the dimensioning of work zone enclosures on stationary grinding machines, which must be operated without an abrasive product guard, burst tests were conducted with vitrified grinding wheels. The studies show that, contrary to widely held opinion, narrower grinding wheels can be more critical concerning the impact resistance than wider wheels although their fragment energy is smaller.

  2. Decay of reverberant sound in a spherical enclosure

    International Nuclear Information System (INIS)

    Carroll, M.M.; Chien, C.F.

    1977-01-01

    The assumption of diffuse reflection (Lambert's Law) leads to integral equations for the wall intensity in a reverberant sound field in the steady state and during decay. The latter equation, in the special case of a spherical enclosure with uniformly absorbent walls and uniform wall intensity, allows exponential decay with a decay time which agrees closely with the Norris--Eyring prediction. The sound-intensity and sound-energy density in the medium, during decay, are also calculated

  3. Managing socio-institutional enclosure: A grounded theory of caregivers' attentiveness in hospital care.

    Science.gov (United States)

    Klaver, Klaartje; Baart, Andries

    2016-06-01

    Caregivers' attentiveness is vital for healthcare quality, yet existing research lacks a specific definition and neglects its different forms and aspects. This paper presents a qualitative, grounded theory of attentiveness in hospital oncology care. Our data show nine types of attentiveness. We answer the question why a caregiver practices one type of attentiveness in a certain situation, and not another type. First, it appears to be of crucial importance whether attentiveness is essential for giving care in the opinion of the caregiver. Second, the focus of attention is essential. Care given by doctors and nurses is always ambivalent; on the one hand, it concerns the body, and on the other hand, it involves the person whom that body belongs to. What is the caregiver (mainly) focused on? The significance of socio-institutional enclosure emerged as a key theme within the findings. Socio-institutional enclosure concerns the space a caregiver may or may not experience to break free from the preponderant institutional orientation towards the physical body of the patient. At the intersection of the influence of socio-institutional enclosure and the substance of the caregivers' concepts of care, three cultures are found that comprise the different types of attentiveness. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Functions and requirements for subsurface barriers used in support of single-shell tank waste retrieval

    International Nuclear Information System (INIS)

    Lowe, S.S.

    1993-01-01

    The mission of the Tank Waste Remediation System (TWRS) Program is to store, treat, and immobilize highly radioactive Hanford waste in an environmentally sound, safe, and cost-effective manner. The scope of the TWRS Program includes project and program activities for receiving, storing, maintaining, treating, and disposing onsite, or packaging for offsite disposal, all Hanford tank waste. Hanford tank waste includes the contents of 149 single-shell tanks (SSTs) and 28 double-shell tanks (DSTs), plus any new waste added to these facilities, and all encapsulated cesium and strontium stored onsite and returned from offsite users. A key element of the TWRS Program is retrieval of the waste in the SSTs. The waste stored in these underground tanks must be removed in order to minimize environmental, safety, and health risks associated with continuing waste storage. Subsurface barriers are being considered as a means to mitigate the effects of tank leaks including those occurring during SST waste retrieval. The functions to be performed by subsurface barriers based on their role in retrieving waste from the SSTs are described, and the requirements which constrain their application are identified. These functions and requirements together define the functional baseline for subsurface barriers

  5. Solving multi-objective facility location problem using the fuzzy analytical hierarchy process and goal programming: a case study on infectious waste disposal centers

    Directory of Open Access Journals (Sweden)

    Narong Wichapa

    Full Text Available The selection of a suitable location for infectious waste disposal is one of the major problems in waste management. Determining the location of infectious waste disposal centers is a difficult and complex process because it requires combining social and environmental factors that are hard to interpret, and cost factors that require the allocation of resources. Additionally, it depends on several regulations. Based on the actual conditions of a case study, forty hospitals and three candidate municipalities in the sub-Northeast region of Thailand, we considered multiple factors such as infrastructure, geological and social & environmental factors, calculating global priority weights using the fuzzy analytical hierarchy process (FAHP. After that, a new multi-objective facility location problem model which combines FAHP and goal programming (GP, namely the FAHP-GP model, was tested. The proposed model can lead to selecting new suitable locations for infectious waste disposal by considering both total cost and final priority weight objectives. The novelty of the proposed model is the simultaneous combination of relevant factors that are difficult to interpret and cost factors, which require the allocation of resources. Keywords: Multi-objective facility location problem, Fuzzy analytic hierarchy process, Infectious waste disposal centers

  6. Multi-functional quantum router using hybrid opto-electromechanics

    Science.gov (United States)

    Ma, Peng-Cheng; Yan, Lei-Lei; Chen, Gui-Bin; Li, Xiao-Wei; Liu, Shu-Jing; Zhan, You-Bang

    2018-03-01

    Quantum routers engineered with multiple frequency bands play a key role in quantum networks. We propose an experimentally accessible scheme for a multi-functional quantum router, using photon-phonon conversion in a hybrid opto-electromechanical system. Our proposed device functions as a bidirectional, tunable multi-channel quantum router, and demonstrates the possibility to route single optical photons bidirectionally and simultaneously to three different output ports, by adjusting the microwave power. Further, the device also behaves as an interswitching unit for microwave and optical photons, yielding probabilistic routing of microwave (optical) signals to optical (microwave) outports. With respect to potential application, we verify the insignificant influence from vacuum and thermal noises in the performance of the router under cryogenic conditions.

  7. Vibration measurements of the Daniel K. Inouye Solar Telescope mount, Coudé rotator, and enclosure assemblies

    Science.gov (United States)

    McBride, William R.; McBride, Daniel R.

    2016-08-01

    The Daniel K. Inouye Solar Telescope (DKIST) will be the largest solar telescope in the world, with a 4-meter off-axis primary mirror and 16 meter rotating Coudé laboratory within the telescope pier. The off-axis design requires a mount similar to an 8-meter on-axis telescope. Both the telescope mount and the Coudé laboratory utilize a roller bearing technology in place of the more commonly used hydrostatic bearings. The telescope enclosure utilizes a crawler mechanism for the altitude axis. As these mechanisms have not previously been used in a telescope, understanding the vibration characteristics and the potential impact on the telescope image is important. This paper presents the methodology used to perform jitter measurements of the enclosure and the mount bearings and servo system in a high-noise environment utilizing seismic accelerometers and high dynamic-range data acquisition equipment, along with digital signal processing (DSP) techniques. Data acquisition and signal processing were implemented in MATLAB. In the factory acceptance testing of the telescope mount, multiple accelerometers were strategically located to capture the six axes-of-motion of the primary and secondary mirror dummies. The optical sensitivity analysis was used to map these mirror mount displacements and rotations into units of image motion on the focal plane. Similarly, tests were done with the Coudé rotator, treating the entire rotating instrument lab as a rigid body. Testing was performed by recording accelerometer data while the telescope control system performed tracking operations typical of various observing scenarios. The analysis of the accelerometer data utilized noise-averaging fast Fourier transform (FFT) routines, spectrograms, and periodograms. To achieve adequate dynamic range at frequencies as low as 3Hz, the use of special filters and advanced windowing functions were necessary. Numerous identical automated tests were compared to identify and select the data sets

  8. Compilation and analysis of national and international OPEX for Safe Enclosure prior to decommissioning

    International Nuclear Information System (INIS)

    Dinner, Paul J.C.; Heimlich, Karel

    2016-01-01

    Around the world, a large number of aging nuclear plants are approaching final shutdown. While this is largely driven by plants reaching the end of their design life, economic factors such as low gas prices (in North America) and the smaller unit size of early commercial reactors are important contributors to this trend. In several instances, economic pressures have resulted in a need for a more rapid transition to Safe Enclosure than originally anticipated. Thus plans for this transition taking into account experience with Safe Enclosure periods of varying lengths are being actively prepared in many jurisdictions. The IAEA as well as other national and international authorities have long recognized the importance of the topic of Safe Enclosure and provided guidance, and the IAEA has recently undertaken a study of 'Lessons Learned from Deferred Decommissioning of Nuclear Facilities'. Beginning with preliminary experience from Canadian CANDU reactors in extended shutdown or safe enclosure, this paper aims to compare this experience with the larger pool of experience from the international community to: - classify the main issues or themes, - examine means to mitigate these, and - formulate general measures of 'good practice'. Compilation of this experience represents the first steps towards a comprehensive, searchable database potentially of use to many in the decommissioning community. Tabulation and analysis of the complete list (comprising approximately 70 cases) has provided the 'short list' of issues presented in Table 1. Examples of the most important listed issues are discussed. The authors' objective is to stimulate interest in extending this compilation. In this way it will continue to grow and benefit all those preparing for transition to decommissioning. (authors)

  9. Compilation and analysis of national and international OPEX or safe enclosure prior to decommissioning

    International Nuclear Information System (INIS)

    Dinner, Paul J.C.; Heimlich, Karel

    2016-01-01

    Around the world, a large number of aging nuclear plants are approaching final shutdown. While this is largely driven by plants reaching the end of their design life, economic factors such as low gas prices (in North America) and the smaller unit size of early commercial reactors are important contributors to this trend. In several instances, economic pressures have resulted in a need for a more rapid transition to Safe Enclosure than originally anticipated. Thus plans for this transition taking into account experience with Safe Enclosure periods of varying lengths are being actively prepared in many jurisdictions. The IAEA as well as other national and international authorities have long recognized the importance of the topic of Safe Enclosure and provided guidance [1-7], and the IAEA has recently undertaken a study of 'Lessons Learned from Deferred Decommissioning of Nuclear Facilities' [8]. Beginning with preliminary experience from Canadian CANDU reactors in extended shutdown or safe enclosure, this paper aims to compare this experience with the larger pool of experience from the international community to: - classify the main issues or themes, - examine means to mitigate these, and - formulate general measures of 'good practice'. Compilation of this experience represents the first steps towards a comprehensive, searchable database potentially of use to many in the decommissioning community. Tabulation and analysis of the complete list (comprising approximately 70 cases) has provided the 'short list' of issues presented. Examples of the most important listed issues are discussed. The authors' objective is to stimulate interest in extending this compilation. In this way it will continue to grow and benefit all those preparing for transition to decommissioning. (authors)

  10. Soil engineering in vivo: harnessing natural biogeochemical systems for sustainable, multi-functional engineering solutions.

    Science.gov (United States)

    DeJong, Jason T; Soga, Kenichi; Banwart, Steven A; Whalley, W Richard; Ginn, Timothy R; Nelson, Douglas C; Mortensen, Brina M; Martinez, Brian C; Barkouki, Tammer

    2011-01-06

    Carbon sequestration, infrastructure rehabilitation, brownfields clean-up, hazardous waste disposal, water resources protection and global warming-these twenty-first century challenges can neither be solved by the high-energy consumptive practices that hallmark industry today, nor by minor tweaking or optimization of these processes. A more radical, holistic approach is required to develop the sustainable solutions society needs. Most of the above challenges occur within, are supported on, are enabled by or grown from soil. Soil, contrary to conventional civil engineering thought, is a living system host to multiple simultaneous processes. It is proposed herein that 'soil engineering in vivo', wherein the natural capacity of soil as a living ecosystem is used to provide multiple solutions simultaneously, may provide new, innovative, sustainable solutions to some of these great challenges of the twenty-first century. This requires a multi-disciplinary perspective that embraces the science of biology, chemistry and physics and applies this knowledge to provide multi-functional civil and environmental engineering designs for the soil environment. For example, can native soil bacterial species moderate the carbonate cycle in soils to simultaneously solidify liquefiable soil, immobilize reactive heavy metals and sequester carbon-effectively providing civil engineering functionality while clarifying the ground water and removing carbon from the atmosphere? Exploration of these ideas has begun in earnest in recent years. This paper explores the potential, challenges and opportunities of this new field, and highlights one biogeochemical function of soil that has shown promise and is developing rapidly as a new technology. The example is used to propose a generalized approach in which the potential of this new field can be fully realized.

  11. Soil engineering in vivo: harnessing natural biogeochemical systems for sustainable, multi-functional engineering solutions

    Science.gov (United States)

    DeJong, Jason T.; Soga, Kenichi; Banwart, Steven A.; Whalley, W. Richard; Ginn, Timothy R.; Nelson, Douglas C.; Mortensen, Brina M.; Martinez, Brian C.; Barkouki, Tammer

    2011-01-01

    Carbon sequestration, infrastructure rehabilitation, brownfields clean-up, hazardous waste disposal, water resources protection and global warming—these twenty-first century challenges can neither be solved by the high-energy consumptive practices that hallmark industry today, nor by minor tweaking or optimization of these processes. A more radical, holistic approach is required to develop the sustainable solutions society needs. Most of the above challenges occur within, are supported on, are enabled by or grown from soil. Soil, contrary to conventional civil engineering thought, is a living system host to multiple simultaneous processes. It is proposed herein that ‘soil engineering in vivo’, wherein the natural capacity of soil as a living ecosystem is used to provide multiple solutions simultaneously, may provide new, innovative, sustainable solutions to some of these great challenges of the twenty-first century. This requires a multi-disciplinary perspective that embraces the science of biology, chemistry and physics and applies this knowledge to provide multi-functional civil and environmental engineering designs for the soil environment. For example, can native soil bacterial species moderate the carbonate cycle in soils to simultaneously solidify liquefiable soil, immobilize reactive heavy metals and sequester carbon—effectively providing civil engineering functionality while clarifying the ground water and removing carbon from the atmosphere? Exploration of these ideas has begun in earnest in recent years. This paper explores the potential, challenges and opportunities of this new field, and highlights one biogeochemical function of soil that has shown promise and is developing rapidly as a new technology. The example is used to propose a generalized approach in which the potential of this new field can be fully realized. PMID:20829246

  12. Study of Multi-Function Micro-Plasma Spraying Technology

    International Nuclear Information System (INIS)

    Wang Liuying; Wang Hangong; Hua Shaochun; Cao Xiaoping

    2007-01-01

    A multi-functional micro-arc plasma spraying system was developed according to aerodynamics and plasma spray theory. The soft switch IGBT (Insulated Gate Bipolar Transistor) invert technique, micro-computer control technique, convergent-divergent nozzle structure and axial powder feeding techniques have been adopted in the design of the micro-arc plasma spraying system. It is not only characterized by a small volume, a light weight, highly accurate control, high deposition efficiency and high reliability, but also has multi-functions in plasma spraying, welding and quenching. The experimental results showed that the system can produce a supersonic flame at a low power, spray Al 2 O 3 particles at an average speed up to 430 m/s, and make nanostructured AT13 coatings with an average bonding strength of 42.7 MPa. Compared to conventional 9M plasma spraying with a higher power, the coatings with almost the same properties as those by conventional plasma spray can be deposited by multi-functional micro-arc plasma spraying with a lower power plasma arc due to an improved power supply design, spray gun structure and powder feeding method. Moreover, this system is suitable for working with thin parts and undertaking on site repairs, and as a result, the application of plasma spraying will be greatly extended

  13. Biodegradation of uranium-contaminated waste oil

    International Nuclear Information System (INIS)

    Hary, L.F.

    1983-01-01

    The Portsmouth Gaseous Diffusion Plant routinely generates quantities of uranium-contaminated waste oil. The current generation rate of waste oil is approximately 2000 gallons per year. The waste is presently biodegraded by landfarming on open field soil plots. However, due to the environmental concerns associated with this treatment process, studies were conducted to determine the optimum biodegradation conditions required for the destruction of this waste. Tests using respirometric flasks were conducted to determine the biodegradation rate for various types of Portsmouth waste oil. These tests were performed at three different loading rates, and on unfertilized and fertilized soil. Additional studies were conducted to evaluate the effectiveness of open field landfarming versus treatment at a greenhouse-like enclosure for the purpose of maintaining soil temperatures above ambient conditions. The respirometric tests concluded that the optimum waste oil loading rate is 10% weight of oil-carbon/weight of soil (30,600 gallons of uranium-contaminated waste oil/acre) on soils with adjusted carbon:nitrogen and carbon:phosphorus ratios of 60:1 and 800:1, respectively. Also, calculational results indicated that greenhouse technology does not provide a significant increase in biodegradation efficiency. Based on these study results, a 6300 ft. 2 abandoned anaerobic digester sludge drying bed is being modified into a permanent waste oil biodegradation facility. The advantage of using this area is that uranium contamination will be contained by the bed's existing leachate collection system. This modified facility will be capable of handling approximately 4500 gallons of waste oil per year; accordingly current waste generation quantities will be satisfactorily treated. 15 refs., 14 figs., 4 tabs

  14. Design and construction of a 76m long-travel laser enclosure for a space occulter testbed

    Science.gov (United States)

    Galvin, Michael; Kim, Yunjong; Kasdin, N. Jeremy; Sirbu, Dan; Vanderbei, Robert; Echeverri, Dan; Sagolla, Giuseppe; Rousing, Andreas; Balasubramanian, Kunjithapatham; Ryan, Daniel; Shaklan, Stuart; Lisman, Doug

    2016-07-01

    Princeton University is upgrading our space occulter testbed. In particular, we are lengthening it to 76m to achieve flightlike Fresnel numbers. This much longer testbed required an all-new enclosure design. In this design, we prioritized modularity and the use of commercial off-the-shelf (COTS) and semi-COTS components. Several of the technical challenges encountered included an unexpected slow beam drift and black paint selection. Herein we describe the design and construction of this long-travel laser enclosure.

  15. The holographic dictionary for Beta functions of multi-trace coupling constants

    Energy Technology Data Exchange (ETDEWEB)

    Aharony, Ofer [Department of Particle Physics and Astrophysics,Weizmann Institute of Science, Rehovot 7610001 (Israel); Gur-Ari, Guy [Department of Particle Physics and Astrophysics,Weizmann Institute of Science, Rehovot 7610001 (Israel); Stanford Institute for Theoretical Physics, Stanford University, Stanford, California 94305 (United States); Klinghoffer, Nizan [Department of Particle Physics and Astrophysics,Weizmann Institute of Science, Rehovot 7610001 (Israel)

    2015-05-06

    Field theories with weakly coupled holographic duals, such as large N gauge theories, have a natural separation of their operators into ‘single-trace operators’ (dual to single-particle states) and ‘multi-trace operators’ (dual to multi-particle states). There are examples of large N gauge theories where the beta functions of single-trace coupling constants all vanish, but marginal multi-trace coupling constants have non-vanishing beta functions that spoil conformal invariance (even when all multi-trace coupling constants vanish). The holographic dual of such theories should be a classical solution in anti-de Sitter space, in which the boundary conditions that correspond to the multi-trace coupling constants depend on the cutoff scale, in a way that spoils conformal invariance. We argue that this is realized through specific bulk coupling constants that lead to a running of the multi-trace coupling constants. This fills a missing entry in the holographic dictionary.

  16. Procedure for estimating permanent total enclosure costs

    Energy Technology Data Exchange (ETDEWEB)

    Lukey, M.E.; Prasad, C.; Toothman, D.A.; Kaplan, N.

    1999-07-01

    Industries that use add-on control devices must adequately capture emissions before delivering them to the control device. One way to capture emissions is to use permanent total enclosures (PTEs). By definition, an enclosure which meets the US Environmental Protection Agency's five-point criteria is a PTE and has a capture efficiency of 100%. Since costs play an important role in regulatory development, in selection of control equipment, and in control technology evaluations for permitting purposes, EPA has developed a Control Cost Manual for estimating costs of various items of control equipment. EPA's Manual does not contain any methodology for estimating PTE costs. In order to assist environmental regulators and potential users of PTEs, a methodology for estimating PTE costs was developed under contract with EPA, by Pacific Environmental Services, Inc. (PES) and is the subject of this paper. The methodology for estimating PTE costs follows the approach used for other control devices in the Manual. It includes procedures for sizing various components of a PTE and for estimating capital as well as annual costs. It contains verification procedures for demonstrating compliance with EPA's five-point criteria. In addition, procedures are included to determine compliance with Occupational Safety and Health Administration (OSHA) standards. Meeting these standards is an important factor in properly designing PTEs. The methodology is encoded in Microsoft Exel spreadsheets to facilitate cost estimation and PTE verification. Examples are given throughout the methodology development and in the spreadsheets to illustrate the PTE design, verification, and cost estimation procedures.

  17. Procedure for estimating permanent total enclosure costs

    Energy Technology Data Exchange (ETDEWEB)

    Lukey, M E; Prasad, C; Toothman, D A; Kaplan, N

    1999-07-01

    Industries that use add-on control devices must adequately capture emissions before delivering them to the control device. One way to capture emissions is to use permanent total enclosures (PTEs). By definition, an enclosure which meets the US Environmental Protection Agency's five-point criteria is a PTE and has a capture efficiency of 100%. Since costs play an important role in regulatory development, in selection of control equipment, and in control technology evaluations for permitting purposes, EPA has developed a Control Cost Manual for estimating costs of various items of control equipment. EPA's Manual does not contain any methodology for estimating PTE costs. In order to assist environmental regulators and potential users of PTEs, a methodology for estimating PTE costs was developed under contract with EPA, by Pacific Environmental Services, Inc. (PES) and is the subject of this paper. The methodology for estimating PTE costs follows the approach used for other control devices in the Manual. It includes procedures for sizing various components of a PTE and for estimating capital as well as annual costs. It contains verification procedures for demonstrating compliance with EPA's five-point criteria. In addition, procedures are included to determine compliance with Occupational Safety and Health Administration (OSHA) standards. Meeting these standards is an important factor in properly designing PTEs. The methodology is encoded in Microsoft Exel spreadsheets to facilitate cost estimation and PTE verification. Examples are given throughout the methodology development and in the spreadsheets to illustrate the PTE design, verification, and cost estimation procedures.

  18. Functional design criteria radioactive liquid waste line replacement, Project W-087. Revision 3

    International Nuclear Information System (INIS)

    McVey, C.B.

    1994-01-01

    This document provides the functional design criteria for the 222-S Laboratory radioactive waste drain piping and transfer pipeline replacement. The project will replace the radioactive waste drain piping from the hot cells in 222-S to the 219-S Waste Handling Facility and provide a new waste transfer route from 219-S to the 244-S Catch Station in Tank Farms

  19. 9 CFR 3.113 - Primary enclosures used to transport marine mammals.

    Science.gov (United States)

    2010-01-01

    ... marine mammals. 3.113 Section 3.113 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION... the animals, their handlers, or other persons. (d) Marine mammals transported in the same primary... used. Within the primary enclosures used to transport marine mammals, the animals will be maintained on...

  20. Measured surface magnetic field attenuation of shielded windows and wire mesh over an electrically small enclosure

    International Nuclear Information System (INIS)

    Hoeft, L.O.; Hofstra, J.S.; Karaskiewicz, R.J.; Wiser, G.

    1984-01-01

    The surface magnetic field attenuation of five types of shielded transparency (window) material was measured over the frequency range 10 kHz to 100 MHz by installing them on an .61 m x .61 m x .2 m enclosure, placing the enclosure on the wall of a TEM cell and measuring the surface and interior magnetic fields using a computer-controlled network analyzer system. The samples included two thicknesses of conductive grids on acrylic, hardware, cloth with 1/8 and 1/4-inch mesh, and a fine mesh laminated optical display window. These measurements are indicative of an enclosure with aperture coupling; namely, they become frequency-independent at high frequencies. Coarse mesh samples (1/8-1/4-inch mesh) were able to provide 50 to 60 dB of magnetic field reduction at tens of MHz, whereas the finer mesh did slightly better. This behavior is consistent with magnetic polarizability theory. Material thickness did not have an appreciable effect for frequencies above a MHz

  1. A multi-function low solide angle system

    International Nuclear Information System (INIS)

    Yan Sujuan; Yao Linong

    2001-01-01

    A multi-function low solid angle system for direct and indirect measurement of radioactivity or emission rate of most α, β and EC emitting nuclides are described in this paper. The measurement result of 241 Am and 90 Sr- 90 Y are given

  2. Sound absorption effects in a rectangular enclosure with the foamed aluminum sheet absorber

    International Nuclear Information System (INIS)

    Oh, Jae Eung; Chung, Jin Tai; Kim, Sang Hun; Chung, Kyung Ryul

    1998-01-01

    For the purpose of finding out the optimal thickness of sound absorber and the sound absorption effects due to the selected thickness at an interested frequency range, the analytical study identifies the interior and exterior sound field characteristics of a rectangular enclosure with foamed aluminum lining and the experimental verification is performed with random noise input. By using a two-microphone impedance tube, we measure experimentally the absorption coefficient and the impedance of simple sound absorbing materials. Measured acoustical parameters of the test samples are applied to the theoretical analysis to predict sound pressure field in the cavity. The sound absorption effects from measurements are compared to predicted ones in both cases with and without foamed aluminum lining in the cavity of the rectangular enclosure

  3. Interactions between piscivores, zooplanktivores and zooplankton in submerged macrophytes : Preliminary observations from enclosure and pond experiments

    DEFF Research Database (Denmark)

    Jacobsen, Lene; Perrow, M.R.; Landkildehus, F.

    1997-01-01

    behavioural changes of zooplanktivores has received little attention, even though this may be an important mechanism in enhancing the stability of submerged macrophytes in shallow lakes. Preliminary observations from an unreplicated large-scale field enclosure experiment and a replicated pond experiment...... and the presence of zooplanktivores typically changed the habitat selection of cladoceran zooplankton. In the case of piscivore/zooplanktivore interactions, the risk of predation was enough to generate clear responses even where the losses to predation were low. However, only in the enclosure experiment...

  4. Reliability assessment of embedded digital system using multi-state function

    International Nuclear Information System (INIS)

    Choi, Jong Gyun; Seong, Poong Hyun

    2006-01-01

    This work describes a combinatorial model for estimating the reliability of the embedded digital system by means of multi-state function. This model includes a coverage model for fault-handling techniques implemented in digital systems. The fault-handling techniques make it difficult for many types of components in digital system to be treated as binary state, good or bad. The multi-state function provides a complete analysis of multi-state systems as which the digital systems can be regarded. Through adaptation of software operational profile flow to multi-state function, the HW/SW interaction is also considered for estimation of the reliability of digital system. Using this model, we evaluate the reliability of one board controller in a digital system, Interposing Logic System (ILS), which is installed in YGN nuclear power units 3 and 4. Since the proposed model is a generalized combinatorial model, the simplification of this model becomes the conventional model that treats the system as binary state. This modeling method is particularly attractive for embedded systems in which small sized application software is implemented since it will require very laborious work for this method to be applied to systems with large software

  5. TRANSFER-FUNCTIONS OF A LINEARIZED MULTI-REGION REACTOR

    Energy Technology Data Exchange (ETDEWEB)

    Higgins, Thomas J.

    1963-09-15

    The development of the transfer functions for a linearized multi-region reactor is studied, and an illustration is made of application of the corresponding theory by a numerical illustrative example. (auth)

  6. Moisture ingress into electronics enclosures under isothermal conditions

    DEFF Research Database (Denmark)

    Staliulionis, Zygimantas; Jabbaribehnam, Mirmasoud; Hattel, Jesper Henri

    2016-01-01

    loads are still not understood well by design engineers, therefore this field has become one of the bottlenecks in the electronics system design. The objective of this paper is to model moisture ingress into an electronics enclosure under isothermal conditions. The moisture diffusion model is based......The number of electronics used in outdoor environment is constantly growing. The humidity causes about 19 % of all electronics failures and, especially, moisture increases these problems due to the ongoing process of miniaturization and lower power consumption of electronic components. Moisture...

  7. Fabrication of a Sludge-Conditioning System for processing legacy wastes from the Gunite and Associated Tanks

    International Nuclear Information System (INIS)

    Randolph, J.D.; Lewis, B.E.; Farmer, J.R.; Johnson, M.A.

    2000-01-01

    The Sludge Conditioning System (SCS) for the Gunite and Associated Tanks (GAATs) is designed to receive, monitor, characterize and process legacy waste materials from the South Tank Farm tanks in preparation for final transfer of the wastes to the Melton Valley Storage Tanks (MVSTs), which are located at Oak Ridge National Laboratory. The SCS includes (1) a Primary Conditioning System (PCS) Enclosure for sampling and particle size classification, (2) a Solids Monitoring Test Loop (SMTL) for slurry characterization, (3) a Waste Transfer Pump to retrieve and transfer waste materials from GAAT consolidation tank W-9 to the MVSTs, (4) a PulsAir Mixing System to provide mixing of consolidated sludges for ease of retrieval, and (5) the interconnecting piping and valving. This report presents the design, fabrication, cost, and fabrication schedule information for the SCS

  8. Neutronic design and analysis on dual-cooled waste transmutation blanket for the fusion driven sub-critical system

    International Nuclear Information System (INIS)

    Zheng Shanliang; Wu Yican; Gao Chunjing; Xu Dezheng; Li Jingjing; Zhu Xiaoxiang

    2004-01-01

    Neutronics design and analysis of dual-cooled multi-functional waste transmutation blanket (DWTB) for the fusion driven sub-critical system (FDS) are performed to ensure the system be able to meet the requirements of fuel-sufficiency and more waste transmutation ratio with low initial loading fuel inventory, which is based on 1-D burn-up calculations with home-developed code Visual BUS and the multi-group (175 neutron groups-42 Gamma groups coupled) data library HENDL1.0/MG (Hybrid Evaluated Nuclear Data Library). (authors)

  9. 9 CFR 112.2 - Final container label, carton label, and enclosure.

    Science.gov (United States)

    2010-01-01

    ... carton; (10) In the case of a product which contains an antibiotic added during the production process... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Final container label, carton label, and enclosure. 112.2 Section 112.2 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION...

  10. 9 CFR 3.87 - Primary enclosures used to transport nonhuman primates.

    Science.gov (United States)

    2010-01-01

    ... nonhuman primates. 3.87 Section 3.87 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE..., and Transportation of Nonhuman Primates 2 Transportation Standards § 3.87 Primary enclosures used to transport nonhuman primates. Any person subject to the Animal Welfare regulations (9 CFR parts 1, 2, and 3...

  11. Objective function for the environmental assessment of waste

    International Nuclear Information System (INIS)

    Toy, A.J.; Boegel, J.; Cohen, J.J.

    1976-01-01

    Various waste management systems were examined in order to determine what the environmental impacts might be and to rank the relative importance of those impacts. This examination determined that radiation dose to man was the most significant, and probably overriding, impact. This report describes methods of providing an objective function for dose to man. The search for an objective function began with a reading of Federal Regulations and the output of various standard setting councils and committees. Ample guidance was found on maximum allowable doses to individuals but no guidance on dose to large populations or criteria by which systems could be compared or optimized. Several other ways were postulated by which waste management systems could be evaluated besides maximum allowable dose to individuals. 0.1 man-rem per MW(e)-year was selected as the measure of system performance. This unit compares a rational estimate of population dose commitment with the concurrent benefit

  12. Reliability analysis and component functional allocations for the ESF multi-loop controller design

    International Nuclear Information System (INIS)

    Hur, Seop; Kim, D.H.; Choi, J.K.; Park, J.C.; Seong, S.H.; Lee, D.Y.

    2006-01-01

    This paper deals with the reliability analysis and component functional allocations to ensure the enhanced system reliability and availability. In the Engineered Safety Features, functionally dependent components are controlled by a multi-loop controller. The system reliability of the Engineered Safety Features-Component Control System, especially, the multi-loop controller which is changed comparing to the conventional controllers is an important factor for the Probability Safety Assessment in the nuclear field. To evaluate the multi-loop controller's failure rate of the k-out-of-m redundant system, the binomial process is used. In addition, the component functional allocation is performed to tolerate a single multi-loop controller failure without the loss of vital operation within the constraints of the piping and component configuration, and ensure that mechanically redundant components remain functional. (author)

  13. Numerical Investigation of the Effect of Magnetic Field on Natural Convection in a Curved-Shape Enclosure

    Directory of Open Access Journals (Sweden)

    M. Sheikholeslami

    2013-01-01

    Full Text Available This investigation reports the magnetic field effect on natural convection heat transfer in a curved-shape enclosure. The numerical investigation is carried out using the control volume-based-finite element method (CVFEM. The numerical investigations are performed for various values of Hartmann number and Rayleigh number. The obtained results are depicted in terms of streamlines and isotherms which show the significant effects of Hartmann number on the fluid flow and temperature distribution inside the enclosure. Also, it was found that the Nusselt number decreases with an increase in the Hartmann number.

  14. The prospective usage of the multi-purpose canister and impacts on the waste management and disposal system

    International Nuclear Information System (INIS)

    McLeod, N.B.

    1993-01-01

    The Multi-Purpose Canister (MPC) is designed to be loaded with spent fuel and sealed at reactors and then serve the functions of transport, storage and disposal without reopening. It can be either self-shielded or unshielded, thus requiring compatible overpacks for transport, storage and disposal. The MPC is not a new concept but it may now be viable because of the particular characteristics at Yucca Mountain: larger MPCs are possible because of ramp access to the repository horizon, and the less difficult temperature limits because of in-drift emplacement, rather than borehole emplacement. This paper describes the advantages and disadvantages of adopting the MPC as the principal technology to be employed in the US program. Use of the MPC permits integration of the utility and DOE portions of the system as well as among the elements within the DOE portion. Paradoxically, the principal disadvantage of the MPC is a direct consequence of its merit as an integrating technology. Full integration includes disposability without reopening, and requires that disposability design decisions be made and implemented well in advance of when waste package licensing uncertainties are resolved. There is, therefore, a risk that MPCs loaded prior to waste package licensing will have to be opened. This risk is discussed in terms of probability and consequences and various alternatives for mitigating this risk are discussed

  15. Mathematical modelling of coupled heat and mass transport into an electronic enclosure

    DEFF Research Database (Denmark)

    Staliulionis, Zygimantas; Jabbaribehnam, Mirmasoud; Hattel, Jesper Henri

    2016-01-01

    In contrast to high fidelity CFD codes which require higher computational effort/time, the well-known Resistor-Capacitor (RC) approach requires much lower calculation time, but also with a lower resolution of the geometrical arrangement. Therefore, for enclosures without too complex geometry...

  16. Surveillance and Maintenance Plan for the 105-C Reactor Safe Storage Enclosure

    International Nuclear Information System (INIS)

    Logan, T. E.

    1998-01-01

    This document provides a plan for implementing surveillance and maintenance activities to ensure that the 105-C Reactor Safe Storage Enclosure is maintained in a safe, environmentally secure, and cost-effective manner until subsequent closure during the final disposition phase of decommissioning

  17. Methods for Fabricating Gradient Alloy Articles with Multi-Functional Properties

    Science.gov (United States)

    Hofmann, Douglas C. (Inventor); Borgonia, John Paul C. (Inventor); Dillon, Robert P. (Inventor); Suh, Eric J. (Inventor); Mulder, Jerry L. (Inventor); Gardner, Paul B. (Inventor)

    2015-01-01

    Systems and methods for fabricating multi-functional articles comprised of additively formed gradient materials are provided. The fabrication of multi-functional articles using the additive deposition of gradient alloys represents a paradigm shift from the traditional way that metal alloys and metal/metal alloy parts are fabricated. Since a gradient alloy that transitions from one metal to a different metal cannot be fabricated through any conventional metallurgy techniques, the technique presents many applications. Moreover, the embodiments described identify a broad range of properties and applications.

  18. MHD mixed convection flow and heat transfer in an open C-shaped enclosure using water-copper oxide nanofluid

    Science.gov (United States)

    Armaghani, T.; Esmaeili, H.; Mohammadpoor, Y. A.; Pop, I.

    2018-01-01

    In this paper, the steady mixed convection flow and heat transfer of water-copper oxide nanofluid in an open C-shaped enclosure is investigated numerically. The enclosure is under constant magnetic field. Effects of Richardson number, magnetic and nanofluid volume fraction parameters are studied and discussed. The nanofluid with a cold temperature of T C and a velocity of u c enters the enclosure from the top right corner and exits from the bottom right corner. The vertical wall of the left side is subjected to a hot and constant temperature T h . Also, other walls are insulated. It is found that the heat transfer is increased via increasing the Hartmann and Reynolds numbers. For low Reynolds numbers, the enhances of the Hartman number leads to a slightly increases of the average Nusselt number, but for high Reynolds numbers, the average Nusselt number gets an ascending trend and the increase in the Hartmann number shows its effect more pronounced. Also, with increase in Ri, the effect of nanofluid on the heat transfer increases. Due to practical impotence, the study of mixed convection heat transfer in enclosures and various shaped of cavities has attracted remarkable attentions in the past few decades. Significant applications of the mixed convection flow can be found in atmospheric flows, solar energy storage, heat exchangers, lubrication technology, drying technologies, cooling of the electronic devices, etc. The present results are original and new for the problem of MHD mixed convection flow and heat transfer in an open C-shaped enclosure using water-copper oxide nanofluid. Comparison of the obtained results with those from the open literature (Mahmoodi et al. [24]) is acceptable.

  19. Innovative enclosure dome/observing aperture system design for the MROI Array Telescopes

    Science.gov (United States)

    Busatta, A.; Marchiori, G.; Mian, S.; Payne, I.; Pozzobon, M.

    2010-07-01

    The close-pack array of the MROI necessitated an original design for the Unit Telescope Enclosure (UTE) at Magdalena Ridge Observatory. The Magdalena Ridge Observatory Interferometer (MROI) is a project which comprises an array of up to ten (10) 1.4m diameter mirror telescopes arranged in a "Y" configuration. Each of these telescopes will be housed inside a Unit Telescope Enclosure (UTE) which are relocatable onto any of 28 stations. The most compact configuration includes all ten telescopes, several of which are at a relative distance of less than 8m center to center from each other. Since the minimum angle of the field of regard is 30° with respect to the horizon, it is difficult to prevent optical blockage caused by adjacent UTEs in this compact array. This paper presents the design constraints inherent in meeting the requirement for the close-pack array. An innovative design enclosure was created which incorporates an unique dome/observing aperture system. The description of this system focuses on how the field of regard requirement led to an unique and highly innovative concept that had to be able to operate in the harsh environmental conditions encountered at an altitude of 10,460ft (3,188m). Finally, we describe the wide use of composites materials and structures (e.g. glass/carbon fibres, sandwich panels etc.) on the aperture system which represents the only way to guarantee adequate thermal and environmental protection, compactness, structural stability and limited power consumption due to reduced mass.

  20. A numerical study on buoyancy-driven flow in an inclined square enclosure heated and cooled on adjacent walls

    International Nuclear Information System (INIS)

    Aydin, O.; Uenal, A.; Ayhan, T.

    1999-01-01

    Buoyancy-driven flows in enclosures play a vital role in many engineering applications such as double glazing, ventilation of rooms, nuclear reactor insulation, solar energy collection, cooling of electronic components, and crystal growth in liquids. Here, numerical study on buoyancy-driven laminar flow in an inclined square enclosure heated from one side and cooled from the adjacent side is conducted using finite difference methods. The effect of inclination angle on fluid flow and heat transfer is investigated by varying the angle of inclination between 0 degree and 360degree, and the results are presented in the form of streamlines and isotherms for different inclination angles and Rayleigh numbers. On the basis of the numerical data, the authors determine the critical values of the inclination angle at which the rate of the transfer within the enclosure is either maximum or minimum

  1. Multi-dimensional beam emittance and β-functions

    International Nuclear Information System (INIS)

    Buon, J.

    1993-05-01

    The concept of r.m.s. emittance is extended to the case of several degrees of freedom that are coupled. That multi-dimensional emittance is lower than the product of the emittances attached to each degree of freedom, but is conserved in a linear motion. An envelope-hyperellipsoid is introduced to define the β-functions of the beam envelope. On the contrary of an one-degree of freedom motion, it is emphasized that these envelope functions differ from the amplitude functions of the normal modes of motion as a result of the difference between the Liouville and Lagrange invariants. (author) 4 refs

  2. A multi-purpose unit concept to integrate storage, transportation, and the engineered barrier system

    International Nuclear Information System (INIS)

    Hollaway, W.R.; Rozier, R.; Nitti, D.A.; Williams, J.R.

    1993-01-01

    The Multi-Purpose Unit (MPU) is a new concept for standardizing and integrating the waste management functions of spent fuel storage, transportation, and geologic disposal. The MPU concept would use one unit, composed of a relatively thick-walled inner canister with a multi-purpose overpack, to meet the requirements for storage in 10 CFR 72, transportation in 10 CFR 71, and the engineered barrier system in 10 CFR 60. The MPU concept differs from the recently proposed Multi-Purpose Canister (MPC) concept in that the MPU concept uses a single multi-purpose overpack for storage, transportation, and geologic disposal, while the MPC concept uses separate and unique overpacks for each of these system functions. A design concept for the MPU is presented along with an estimate of unit costs. An initial evaluation of overall system cost showed that the MPU concept could be economically competitive with the current reference system. The MPU concept provides the potential for significant reduction, simplification, and standardization of Civilian Radioactive Waste Management (CRWMS) facilities and operations, including those at the utilities, during waste acceptance and transportation, and at the Monitored Retrievable Storage (MRS) facility and the repository. The primary issues for the MPU concept relate to uncertainties with respect to licensing, and the programmatic risks associated with implementing the MPU concept before the repository design is finalized. The strong potential exhibited by the MPU concept demonstrates that this option merits additional development and should be considered in the next phase of work on multi-purpose concepts for the CRWMS

  3. Radioactive waste isolation in salt: peer review of the Office of Nuclear Waste Isolation's report on Functional Design Criteria for a Repository for High-Level Radioactive Waste

    International Nuclear Information System (INIS)

    Hambley, D.F.; Russell, J.E.; Busch, J.S.; Harrison, W.; Edgar, D.E.; Tisue, M.W.

    1984-08-01

    This report summarizes Argonne's review of the Office of Nuclear Waste Isolation's (ONWI's) draft report entitled Functional Design Criteria for High-Level Nuclear Waste Repository in Salt, dated January 23, 1984. Recommendations are given for improving the ONWI draft report

  4. A Process to Establish the Common Functions Performed by a Multi-Role Vessel

    Science.gov (United States)

    2010-09-01

    25 5.9 EPF – Environmental Protection Functions...Functions WFO Offshore Warfighting Functions EPF Environmental Protection Functions EPF .1 Waste Treatment Functions DSTO-TR-2473 16 HSF...Mission Command Function CFV Vessel Command Function EPF Environmental Protection Functions HSF Hotel Services Functions HVAC HVAC Functions

  5. Functions and requirements document for interim store solidified high-level and transuranic waste

    Energy Technology Data Exchange (ETDEWEB)

    Smith-Fewell, M.A., Westinghouse Hanford

    1996-05-17

    The functions, requirements, interfaces, and architectures contained within the Functions and Requirements (F{ampersand}R) Document are based on the information currently contained within the TWRS Functions and Requirements database. The database also documents the set of technically defensible functions and requirements associated with the solidified waste interim storage mission.The F{ampersand}R Document provides a snapshot in time of the technical baseline for the project. The F{ampersand}R document is the product of functional analysis, requirements allocation and architectural structure definition. The technical baseline described in this document is traceable to the TWRS function 4.2.4.1, Interim Store Solidified Waste, and its related requirements, architecture, and interfaces.

  6. Heat dissipation in controlled environment enclosures through the application of water screens

    Energy Technology Data Exchange (ETDEWEB)

    Warrington, I.J.; Halligan, E.A.; Ruby, L.C.; McNaughton, K.G. [Horticulture and Food Research Institute of New Zealand Ltd., Palmerston North (New Zealand)

    1994-12-31

    The use of plate glass-water thermal barriers in controlled environment facilities effectively reduces the thermal load within the plant growth chamber. This allows high PPFs to be provided for plant growth and development studies, adequate simulation of daily light integrals, and simulation of peak PPFs. Further, substantial amounts of incandescent lamp supplementation can be used to achieve simulation of daylight R:FR ratios which are needed to ensure adequate stem development in some species. While the focus in this paper has been on the use of entire thermal barriers which separate the lighting enclosure from the plant growth chamber, the same principles apply to the use of water jackets for cooling individual lamps (such as can occur with xenon-arc lamps). In this instance, the barrier separating the lamps from the plant chamber can be much simpler (e.g., plexiglas) as the main function of the barrier is to separate the air ventilation of the lamp enclosure from the air system within the plant growth chamber. The main advantage of water as a thermal barrier is the negligible absorption of radiation in the photosynthetically-active and near infra-red wavebands. Consequently, plate glass-water barriers typically allow transmission of approximately 90% of radiation in these regions. While ventilated double and triple glazing systems appear to be attractive alternative to water barriers from an operating standpoint, their significant absorption in the biologically-important wavebands (7 - 12 %) with each glass layer and longer-wave cut-offs (typically 2500 - 4000 nm) makes them a much less attractive alternative. The data presented demonstrate clearly that measurement of PPF alone is not an adequate representation of the radiation environment being used in a controlled environment study.

  7. Thermosolutal convection in saturated porous enclosure with concentrated energy and solute sources

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Di; Zhao, Fu-Yun; Tang, Guang-Fa [College of Civil Engineering, Hunan University, Changsha (China)

    2008-01-15

    Double diffusive natural convection within a vertical porous enclosure with localized heating and salting from one side is numerically studied by the finite element based finite volume method. In the formulation of the problem, use is made of the Darcy model, which allows the slip boundary condition on a solid wall to be satisfied. Comparisons with benchmark solutions for natural convection in fluid saturated porous enclosures are first presented to validate the code. Following that, an extensive series of numerical simulations is conducted in the range of -55 {<=} N {<=} + 55 and 0.125 {<=} L {<=} 0.875, where N and L are the buoyancy ratio and the element location, respectively. Streamlines, heatlines, masslines, isotherms and iso-concentrations in the system are produced to illustrate the flow structure transition from solutal dominated opposing to thermal dominated and solutal dominated aiding flows, respectively. The computed average Nusselt and Sherwood numbers provide guidance for locating the heating and salting element. (author)

  8. Thermosolutal convection in saturated porous enclosure with concentrated energy and solute sources

    Energy Technology Data Exchange (ETDEWEB)

    Liu Di [College of Civil Engineering, Hunan University, Changsha (China)], E-mail: liudi66@163.com; Zhao Fuyun [College of Civil Engineering, Hunan University, Changsha (China)], E-mail: zfycfdnet@163.com; Tang Guangfa [College of Civil Engineering, Hunan University, Changsha (China)], E-mail: gftangcfd@163.com

    2008-01-15

    Double diffusive natural convection within a vertical porous enclosure with localized heating and salting from one side is numerically studied by the finite element based finite volume method. In the formulation of the problem, use is made of the Darcy model, which allows the slip boundary condition on a solid wall to be satisfied. Comparisons with benchmark solutions for natural convection in fluid saturated porous enclosures are first presented to validate the code. Following that, an extensive series of numerical simulations is conducted in the range of -55 {<=} N {<=} + 55 and 0.125 {<=} L {<=} 0.875, where N and L are the buoyancy ratio and the element location, respectively. Streamlines, heatlines, masslines, isotherms and iso-concentrations in the system are produced to illustrate the flow structure transition from solutal dominated opposing to thermal dominated and solutal dominated aiding flows, respectively. The computed average Nusselt and Sherwood numbers provide guidance for locating the heating and salting element.

  9. Waste management system functional requirements for Interim Waste Management Facilities (IWMFs) and technology demonstrations, LLWDDD [Low-Level Disposal Development and Demonstration] Program

    International Nuclear Information System (INIS)

    1988-03-01

    The purpose of this report is to build upon the preceding decisions and body of information to prepare draft system functional requirements for each classification of waste disposal currently proposed for Low-Level Waste Disposal Development Demonstration (LLWDDD) projects. Functional requirements identify specific information and data needs necessary to satisfy engineering design criteria/objectives for Interim Waste Management Facilities. This draft will suppor the alternatives evaluation process and will continue to evolve as strategy is implemented, regulatory limits are established, technical and economic uncertainties are resolved, and waste management plans are being implemented. This document will become the planning basis for the new generation of solid LLW management facilities on new sites on the Reservation. Eighteen (18) general system requirements are identified which are applicable to all four Low-Level Waste (LLW) disposal classifications. Each classification of LLW disposal is individually addressed with respect ot waste characteristics, site considerations, facility operations, facility closure/post-closure, intruder barriers, institutional control, and performance monitoring requirements. Three initial LLW disposal sites have been proposed as locations on the ORR for the first demonstrations

  10. Waste-to-energy, municipal solid waste treatment, and best available technology

    DEFF Research Database (Denmark)

    Wang, Zhenfeng; Ren, Jingzheng; Goodsite, Michael Evan

    2018-01-01

    The treatment of municipal solid waste (MSW) has become an urgently important task of many countries. This objective of this study is to present a novel group multi-attribute decision analysis method for prioritizing the MSW treatment alternatives based on the interval-valued fuzzy set theory...... (DEMATEL) method was developed to determine the weights of the evaluation criteria by considering the independent relationships among these criteria. The multi-actor interval-valued fuzzy grey relational analysis was developed to rank the waste-to-energy scenarios. Four alternative processes for MSW...

  11. Extension problem for generalized multi-monogenic functions in Clifford analysis

    International Nuclear Information System (INIS)

    Tran Quyet Thang.

    1992-10-01

    The main purpose of this paper is to extend some properties of multi-monogenic functions, which is a generalization of monogenic functions in higher dimensions, for a class of functions satisfying Vekua-type generalized Cauchy-Riemann equations in Clifford Analysis. It is proved that the Hartogs theorem is valid for these functions. (author). 7 refs

  12. Functional process descriptions for the program to develop the Nuclear Waste Management System

    International Nuclear Information System (INIS)

    Woods, T.W.

    1991-09-01

    The Office of Civilian Radioactive Waste Management (OCRWM) is executing a plan for improvement of the systems implemented to carry out its responsibilities under the Nuclear Waste Policy Act of 1982 (NWPA). As part of the plan, OCRWM is performing a systems engineering analysis of both the physical system, i.e., the Nuclear Waste Management System (NWMS), and the programmatic functions that must be accomplished to bring the physical system into being. The purpose of the program analysis is to provide a systematic identification and definition of all program functions, functional process flows, and function products necessary and sufficient to provide the physical system. The analysis resulting from this approach provides a basis for development of a comprehensive and integrated set of policies, standard practices, and procedures for the effective and efficient execution of the program. Thus, this analysis will form a basis for revising current OCRWM policies and procedures, or developing new ones is necessary. The primary purposes of this report are as follows: (1) summarizes the major functional processes and process flows that have been developed as a part of the program analysis, and (2) provide an introduction and assistance in understanding the detailed analysis information contained in the three volume report titled The Analysis of the Program to Develop the Nuclear Waste Management System (Woods 1991a)

  13. Functional process descriptions for the program to develop the Nuclear Waste Management System

    Energy Technology Data Exchange (ETDEWEB)

    Woods, T.W.

    1991-09-01

    The Office of Civilian Radioactive Waste Management (OCRWM) is executing a plan for improvement of the systems implemented to carry out its responsibilities under the Nuclear Waste Policy Act of 1982 (NWPA). As part of the plan, OCRWM is performing a systems engineering analysis of both the physical system, i.e., the Nuclear Waste Management System (NWMS), and the programmatic functions that must be accomplished to bring the physical system into being. The purpose of the program analysis is to provide a systematic identification and definition of all program functions, functional process flows, and function products necessary and sufficient to provide the physical system. The analysis resulting from this approach provides a basis for development of a comprehensive and integrated set of policies, standard practices, and procedures for the effective and efficient execution of the program. Thus, this analysis will form a basis for revising current OCRWM policies and procedures, or developing new ones is necessary. The primary purposes of this report are as follows: (1) summarizes the major functional processes and process flows that have been developed as a part of the program analysis, and (2) provide an introduction and assistance in understanding the detailed analysis information contained in the three volume report titled The Analysis of the Program to Develop the Nuclear Waste Management System (Woods 1991a).

  14. Assessment of human body influence on exposure measurements of electric field in indoor enclosures.

    Science.gov (United States)

    de Miguel-Bilbao, Silvia; García, Jorge; Ramos, Victoria; Blas, Juan

    2015-02-01

    Personal exposure meters (PEMs) used for measuring exposure to electromagnetic fields (EMF) are typically used in epidemiological studies. As is well known, these measurement devices cause a perturbation of real EMF exposure levels due to the presence of the human body in the immediate proximity. This paper aims to model the alteration caused by the body shadow effect (BSE) in motion conditions and in indoor enclosures at the Wi-Fi frequency of 2.4 GHz. For this purpose, simulation techniques based on ray-tracing have been carried out, and their results have been verified experimentally. A good agreement exists between simulation and experimental results in terms of electric field (E-field) levels, and taking into account the cumulative distribution function (CDF) of the spatial distribution of amplitude. The Kolmogorov-Smirnov (KS) test provides a P-value greater than 0.05, in fact close to 1. It has been found that the influence of the presence of the human body can be characterized as an angle of shadow that depends on the dimensions of the indoor enclosure. The CDFs show that the E-field levels in indoor conditions follow a lognormal distribution in the absence of the human body and under the influence of BSE. In conclusion, the perturbation caused by BSE in PEMs readings cannot be compensated for by correction factors. Although the mean value is well adjusted, BSE causes changes in CDF that would require improvements in measurement protocols and in the design of measuring devices to subsequently avoid systematic errors. © 2014 Wiley Periodicals, Inc.

  15. Natural convection in enclosures containing lead-bismuth and lead

    International Nuclear Information System (INIS)

    Dzodzo, M.; Cuckovic-Dzodzo, D.

    2001-01-01

    The design of liquid metal reactors such as Encapsulated Nuclear Heat Source (ENHS) which are based predominantly on the flow generated by natural convection effects demands knowledge of velocity and temperature fields, distribution of the local Nusselt numbers and values of the average Nusselt numbers for small coolant velocity regimes. Laminar natural convection in rectangular enclosures with different aspect ratios, containing lead-bismuth and lead is studied numerically in this paper. The numerical model takes into account variable properties of the liquid metals. The developed correlation for average Nusselt numbers is presented. It is concluded that average Nusselt numbers are lower than in 'normal' fluids (air, water and glycerol) for the same values of Rayleigh numbers. However, the heat flux, which can be achieved, is greater due to the high thermal conductivity of liquid metals. Some specific features of the flow fields generated by natural convection in liquid metals are presented. Their consequences on the design of heat exchangers for liquid metals are discussed. An application of the obtained results to the design of a new type of steam generator, which integrates the intermediate heat exchanger and secondary pool functions of the ENHS reactor, is presented. (authors)

  16. An Explicit Enclosure of the Solution Set of Overdetermined Interval Linear Equations

    Czech Academy of Sciences Publication Activity Database

    Rohn, Jiří

    2017-01-01

    Roč. 24, February (2017), s. 1-10 ISSN 1573-1340 Institutional support: RVO:67985807 Keywords : interval linear equations * interval hull * unit midpoint * enclosure Subject RIV: BA - General Mathematics OBOR OECD: Applied mathematics http://interval.louisiana.edu/ reliable -computing-journal/volume-24/ reliable -computing-24-pp-001-010.pdf

  17. Multiple stakeholders in multi-criteria decision-making in the context of Municipal Solid Waste Management: A review

    International Nuclear Information System (INIS)

    Soltani, Atousa; Hewage, Kasun; Reza, Bahareh; Sadiq, Rehan

    2015-01-01

    Highlights: • We review Municipal Solid Waste Management studies with focus on multiple stakeholders. • We focus on studies with multi-criteria decision analysis methods and discover their trends. • Most studies do not offer solutions for situations where stakeholders compete for more benefits or have unequal voting powers. • Governments and experts are the most participated stakeholders and AHP is the most dominant method. - Abstract: Municipal Solid Waste Management (MSWM) is a complicated process that involves multiple environmental and socio-economic criteria. Decision-makers look for decision support frameworks that can guide in defining alternatives, relevant criteria and their weights, and finding a suitable solution. In addition, decision-making in MSWM problems such as finding proper waste treatment locations or strategies often requires multiple stakeholders such as government, municipalities, industries, experts, and/or general public to get involved. Multi-criteria Decision Analysis (MCDA) is the most popular framework employed in previous studies on MSWM; MCDA methods help multiple stakeholders evaluate the often conflicting criteria, communicate their different preferences, and rank or prioritize MSWM strategies to finally agree on some elements of these strategies and make an applicable decision. This paper reviews and brings together research on the application of MCDA for solving MSWM problems with more focus on the studies that have considered multiple stakeholders and offers solutions for such problems. Results of this study show that AHP is the most common approach in consideration of multiple stakeholders and experts and governments/municipalities are the most common participants in these studies

  18. Multiple stakeholders in multi-criteria decision-making in the context of Municipal Solid Waste Management: A review

    Energy Technology Data Exchange (ETDEWEB)

    Soltani, Atousa; Hewage, Kasun; Reza, Bahareh; Sadiq, Rehan, E-mail: Rehan.sadiq@ubc.ca

    2015-01-15

    Highlights: • We review Municipal Solid Waste Management studies with focus on multiple stakeholders. • We focus on studies with multi-criteria decision analysis methods and discover their trends. • Most studies do not offer solutions for situations where stakeholders compete for more benefits or have unequal voting powers. • Governments and experts are the most participated stakeholders and AHP is the most dominant method. - Abstract: Municipal Solid Waste Management (MSWM) is a complicated process that involves multiple environmental and socio-economic criteria. Decision-makers look for decision support frameworks that can guide in defining alternatives, relevant criteria and their weights, and finding a suitable solution. In addition, decision-making in MSWM problems such as finding proper waste treatment locations or strategies often requires multiple stakeholders such as government, municipalities, industries, experts, and/or general public to get involved. Multi-criteria Decision Analysis (MCDA) is the most popular framework employed in previous studies on MSWM; MCDA methods help multiple stakeholders evaluate the often conflicting criteria, communicate their different preferences, and rank or prioritize MSWM strategies to finally agree on some elements of these strategies and make an applicable decision. This paper reviews and brings together research on the application of MCDA for solving MSWM problems with more focus on the studies that have considered multiple stakeholders and offers solutions for such problems. Results of this study show that AHP is the most common approach in consideration of multiple stakeholders and experts and governments/municipalities are the most common participants in these studies.

  19. Viscous dissipation and radiation effects on MHD natural convection in a square enclosure filled with a porous medium

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Sameh E., E-mail: sameh_sci_math@yahoo.com [Department of Mathematics, Faculty of Sciences, South Valley University, Qena (Egypt); Hussein, Ahmed Kadhim, E-mail: ahmedkadhim7474@gmail.com [College of Engineering, Mechanical Engineering Department, Babylon University, Babylon City—Hilla (Iraq); Mohammed, H.A. [Department of Thermofluids, Faculty of Mechanical Engineering, University Teknologi Malaysia (UTM), 81310 UTM Skudai, Johor Bahru (Malaysia); Adegun, I.K. [Department of Mechanical Engineering, University of Ilorin, Ilorin (Nigeria); Zhang, Xiaohui [School of Physics Science and Technology, School of Energy—Soochow University, Suzhou 215006, Jiangsu (China); Kolsi, Lioua [Unite de Metrologie en Mecanique des Fluides et Thermique, Ecole Nationale d’Ingenieurs, Monastir (Tunisia); Hasanpour, Arman [Department of Mechanical Engineering, Babol University of Technology, PO Box 484, Babol (Iran, Islamic Republic of); Sivasankaran, S. [Institute of Mathematical Sciences, University of Malaya, Kuala Lumpur 50603 (Malaysia)

    2014-01-15

    Highlights: • Ha decelerates the flow field. • Ha enhances conduction. • Magnetic field orientation is important. • Radiation parameter important. • Nu decreases as Ha increases. -- Abstract: Numerical two-dimensional analysis using finite difference approach with “line method” is performed on the laminar magneto-hydrodynamic natural convection in a square enclosure filled with a porous medium to investigate the effects of viscous dissipation and radiation. The enclosure heated from left vertical sidewall and cooled from an opposing right vertical sidewall. The top and bottom walls of the enclosure are considered adiabatic. The flow in the square enclosure is subjected to a uniform magnetic field at various orientation angles (φ = 0°, 30°, 45°, 60° and 90°). Numerical computations occur at wide ranges of Rayleigh number, viscous dissipation parameter, magnetic field orientation angles, Hartmann number and radiation parameter. Numerical results are presented with the aid of tables and graphical illustrations. The results of the present work explain that the local and average Nusselt numbers at the hot and cold sidewalls increase with increasing the radiation parameter. From the other side, the role of viscous dissipation parameter is to reduce the local and average Nusselt numbers at the hot left wall, while it improves them at the cold right wall. The results are compared with another published results and it found to be in a good agreement.

  20. The Multi-Criteria Negotiation Analysis Based on the Membership Function

    Directory of Open Access Journals (Sweden)

    Roszkowska Ewa

    2014-08-01

    Full Text Available In this paper we propose a multi-criteria model based on the fuzzy preferences approach which can be implemented in the prenegotiation phase to evaluate the negotiations packages. The applicability of some multi-criteria ranking methods were discussed for building a scoring function for negotiation packages. The first one is Simple Additive Weighting (SAW technique which determines the sum of the partial satisfactions from each negotiation issue and aggregate them using the issue weights. The other one is Distance Based Methods (DBM, with its extension based on the distances to ideal or anti-ideal package, i.e. the TOPSIS procedure. In our approach the negotiator's preferences over the issues are represented by fuzzy membership functions and next a selected multi-criteria decision making method is adopted to determine the global rating of each package. The membership functions are used here as the equivalents of utility functions spread over the negotiation issues, which let us compare different type of data. One of the key advantages of the approach proposed is its usefulness for building a general scoring function in the ill-structured negotiation problem, namely the situation in which the problem itself as well as the negotiators preferences cannot be precisely defined, the available information is uncertain, subjective and vague. Secondly, all proposed variants of scoring functions produce consistent rankings, even though the new packages are added (or removed and do not result in rank reversal.

  1. Multi-element probabilistic collocation method in high dimensions

    International Nuclear Information System (INIS)

    Foo, Jasmine; Karniadakis, George Em

    2010-01-01

    We combine multi-element polynomial chaos with analysis of variance (ANOVA) functional decomposition to enhance the convergence rate of polynomial chaos in high dimensions and in problems with low stochastic regularity. Specifically, we employ the multi-element probabilistic collocation method MEPCM and so we refer to the new method as MEPCM-A. We investigate the dependence of the convergence of MEPCM-A on two decomposition parameters, the polynomial order μ and the effective dimension ν, with ν<< N, and N the nominal dimension. Numerical tests for multi-dimensional integration and for stochastic elliptic problems suggest that ν≥μ for monotonic convergence of the method. We also employ MEPCM-A to obtain error bars for the piezometric head at the Hanford nuclear waste site under stochastic hydraulic conductivity conditions. Finally, we compare the cost of MEPCM-A against Monte Carlo in several hundred dimensions, and we find MEPCM-A to be more efficient for up to 600 dimensions for a specific multi-dimensional integration problem involving a discontinuous function.

  2. CFD simulation and statistical analysis of moisture transfer into an electronic enclosure

    DEFF Research Database (Denmark)

    Shojaee Nasirabadi, Parizad; Jabbaribehnam, Mirmasoud; Hattel, Jesper Henri

    2017-01-01

    CFD model for the isothermal case. The model is then combined with a two level factorial design to identify the significant factors as well as the potential interactions us- ing the numerical simulation results. In the second part of this study, a non-isothermal case is studied, in which the enclosure...

  3. Energy efficiency in multi-story buildings

    Directory of Open Access Journals (Sweden)

    Staritcyna Anastasiia

    2016-01-01

    Full Text Available In this project a research on energy efficiency of Malta house was provided, it is a residential multi-story building in Helsinki, Jätkäsaari area. This project describes introduction with a new heating system for residential dwellings, which uses only heated air. To maintain air temperature in comfort level heat recovery and district heating is used in the same system. The task was to research efficacy of the enclosure structures. For research the 3D model has been created in the program the Revit 2015 and Lumion 13. Thermotechnical calculation for three types of a design has been executed in the program U-value.net.

  4. Ratios of colony mass to thermal conductance of tree and man-made nest enclosures of Apis mellifera: implications for survival, clustering, humidity regulation and Varroa destructor

    Science.gov (United States)

    Mitchell, Derek

    2016-05-01

    In the absence of human intervention, the honeybee ( Apis mellifera L.) usually constructs its nest in a tree within a tall, narrow, thick-walled cavity high above the ground (the enclosure); however, most research and apiculture is conducted in the thin-walled, squat wooden enclosures we know as hives. This experimental research, using various hives and thermal models of trees, has found that the heat transfer rate is approximately four to seven times greater in the hives in common use, compared to a typical tree enclosure in winter configuration. This gives a ratio of colony mass to lumped enclosure thermal conductance (MCR) of less than 0.8 kgW-1 K for wooden hives and greater than 5 kgW-1 K for tree enclosures. This result for tree enclosures implies higher levels of humidity in the nest, increased survival of smaller colonies and lower Varroa destructor breeding success. Many honeybee behaviours previously thought to be intrinsic may only be a coping mechanism for human intervention; for example, at an MCR of above 2 kgW-1 K, clustering in a tree enclosure may be an optional, rare, heat conservation behaviour for established colonies, rather than the compulsory, frequent, life-saving behaviour that is in the hives in common use. The implied improved survival in hives with thermal properties of tree nests may help to solve some of the problems honeybees are currently facing in apiculture.

  5. A multi-criteria analysis of options for energy recovery from municipal solid waste in India and the UK.

    Science.gov (United States)

    Yap, H Y; Nixon, J D

    2015-12-01

    Energy recovery from municipal solid waste plays a key role in sustainable waste management and energy security. However, there are numerous technologies that vary in suitability for different economic and social climates. This study sets out to develop and apply a multi-criteria decision making methodology that can be used to evaluate the trade-offs between the benefits, opportunities, costs and risks of alternative energy from waste technologies in both developed and developing countries. The technologies considered are mass burn incineration, refuse derived fuel incineration, gasification, anaerobic digestion and landfill gas recovery. By incorporating qualitative and quantitative assessments, a preference ranking of the alternative technologies is produced. The effect of variations in decision criteria weightings are analysed in a sensitivity analysis. The methodology is applied principally to compare and assess energy recovery from waste options in the UK and India. These two countries have been selected as they could both benefit from further development of their waste-to-energy strategies, but have different technical and socio-economic challenges to consider. It is concluded that gasification is the preferred technology for the UK, whereas anaerobic digestion is the preferred technology for India. We believe that the presented methodology will be of particular value for waste-to-energy decision-makers in both developed and developing countries. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Influence of climate change on the multi-generation toxicity to Enchytraeus crypticus of soils polluted by metal/metalloid mining wastes

    NARCIS (Netherlands)

    Barmentlo, S.H.; van Gestel, C.A.M.; Alvarez-Rogel, J.; Gonzalez Alcaraz, M.N.

    2017-01-01

    This study aimed at assessing the effects of increased air temperature and reduced soil moisture content on the multi-generation toxicity of a soil polluted by metal/metalloid mining wastes. Enchytraeus crypticus was exposed to dilution series of the polluted soil in Lufa 2.2 soil under different

  7. A Literature Review and Compilation of Nuclear Waste Management System Attributes for Use in Multi-Objective System Evaluations.

    Energy Technology Data Exchange (ETDEWEB)

    Kalinina, Elena Arkadievna [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Samsa, Michael [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-11-01

    The purpose of this work was to compile a comprehensive initial set of potential nuclear waste management system attributes. This initial set of attributes is intended to serve as a starting point for additional consideration by system analysts and planners to facilitate the development of a waste management system multi-objective evaluation framework based on the principles and methodology of multi-attribute utility analysis. The compilation is primarily based on a review of reports issued by the Canadian Nuclear Waste Management Organization (NWMO) and the Blue Ribbon Commission on America's Nuclear Future (BRC), but also an extensive review of the available literature for similar and past efforts as well. Numerous system attributes found in different sources were combined into a single objectives-oriented hierarchical structure. This study provides a discussion of the data sources and the descriptions of the hierarchical structure. A particular focus of this study was on collecting and compiling inputs from past studies that involved the participation of various external stakeholders. However, while the important role of stakeholder input in a country's waste management decision process is recognized in the referenced sources, there are only a limited number of in-depth studies of the stakeholders' differing perspectives. Compiling a comprehensive hierarchical listing of attributes is a complex task since stakeholders have multiple and often conflicting interests. The BRC worked for two years (January 2010 to January 2012) to "ensure it has heard from as many points of view as possible." The Canadian NWMO study took four years and ample resources, involving national and regional stakeholders' dialogs, internet-based dialogs, information and discussion sessions, open houses, workshops, round tables, public attitude research, website, and topic reports. The current compilation effort benefited from the distillation of these many varied inputs

  8. A Literature Review and Compilation of Nuclear Waste Management System Attributes for Use in Multi-Objective System Evaluations

    International Nuclear Information System (INIS)

    Kalinina, Elena Arkadievna; Samsa, Michael

    2015-01-01

    The purpose of this work was to compile a comprehensive initial set of potential nuclear waste management system attributes. This initial set of attributes is intended to serve as a starting point for additional consideration by system analysts and planners to facilitate the development of a waste management system multi-objective evaluation framework based on the principles and methodology of multi-attribute utility analysis. The compilation is primarily based on a review of reports issued by the Canadian Nuclear Waste Management Organization (NWMO) and the Blue Ribbon Commission on America's Nuclear Future (BRC), but also an extensive review of the available literature for similar and past efforts as well. Numerous system attributes found in different sources were combined into a single objectives-oriented hierarchical structure. This study provides a discussion of the data sources and the descriptions of the hierarchical structure. A particular focus of this study was on collecting and compiling inputs from past studies that involved the participation of various external stakeholders. However, while the important role of stakeholder input in a country's waste management decision process is recognized in the referenced sources, there are only a limited number of in-depth studies of the stakeholders' differing perspectives. Compiling a comprehensive hierarchical listing of attributes is a complex task since stakeholders have multiple and often conflicting interests. The BRC worked for two years (January 2010 to January 2012) to 'ensure it has heard from as many points of view as possible.' The Canadian NWMO study took four years and ample resources, involving national and regional stakeholders' dialogs, internet-based dialogs, information and discussion sessions, open houses, workshops, round tables, public attitude research, website, and topic reports. The current compilation effort benefited from the distillation of these many varied inputs conducted by the

  9. Air-tight disposing device for solid radioactive waste

    International Nuclear Information System (INIS)

    Aoyama, Saburo.

    1976-01-01

    Object: In a construction for air-tightly connecting radioactive material handling equipment with a radioactive waste container through a vinyl bag, to use a multi-stage expansion tube to introduce the radioactive waste into the waste container in safe and positive manner. Structure: During normal operation in the radioactive material handling equipment, a multi-stage expansion cylinder is extended by operation of a remote shaft to suitably throw the waste in a state with a vinyl bag protected, whereas when the waste is disposed away from the equipment, the multi-stage expansion cylinder is contracted and received into a holder, and the vinyl bag is heated and sealed at a given position and cut, after which a cover of an outer container for disposal is closed and carried out. The vinyl bag remained on the side of the holder after sealed and cut is put into the waste container after a fresh vinyl bag, in which another waste container is received, has been secured to the holder. (Taniai, N.)

  10. Time-dependent density functional theory for multi-component systems

    International Nuclear Information System (INIS)

    Tiecheng Li; Peiqing Tong

    1985-10-01

    The Runge-Gross version of Hohenberg-Kohn-Sham's density functional theory is generalized to multi-component systems, both for arbitrary time-dependent pure states and for arbitrary time-dependent ensembles. (author)

  11. Synthesis of Multi-Walled Carbon Nanotubes from Plastic Waste Using a Stainless-Steel CVD Reactor as Catalyst.

    Science.gov (United States)

    Tripathi, Pranav K; Durbach, Shane; Coville, Neil J

    2017-09-22

    The disposal of non-biodegradable plastic waste without further upgrading/downgrading is not environmentally acceptable and many methods to overcome the problem have been proposed. Herein we indicate a simple method to make high-value nanomaterials from plastic waste as a partial solution to the environmental problem. Laboratory-based waste centrifuge tubes made of polypropylene were chosen as a carbon source to show the process principle. In the process, multi-walled carbon nanotubes (MWCNTs) were synthesized from plastic waste in a two-stage stainless steel 316 (SS 316) metal tube that acted as both reactor vessel and catalyst. The steel reactor contains Fe (and Ni, and various alloys), which act as the catalyst for the carbon conversion process. The reaction and products were studied using electron probe microanalysis, thermogravimetric analysis, Raman spectroscopy and transmission electron microscopy and scanning electron microscopy. Optimization studies to determine the effect of different parameters on the process showed that the highest yield and most graphitized MWCNTs were formed at 900 °C under the reaction conditions used (yield 42%; Raman I D / I G ratio = 0.48). The high quality and high yield of the MWCNTs that were produced in a flow reactor from plastic waste using a two stage SS 316 chemical vapor deposition (CVD) furnace did not require the use of an added catalyst.

  12. Synthesis of Multi-Walled Carbon Nanotubes from Plastic Waste Using a Stainless-Steel CVD Reactor as Catalyst

    Directory of Open Access Journals (Sweden)

    Pranav K. Tripathi

    2017-09-01

    Full Text Available The disposal of non-biodegradable plastic waste without further upgrading/downgrading is not environmentally acceptable and many methods to overcome the problem have been proposed. Herein we indicate a simple method to make high-value nanomaterials from plastic waste as a partial solution to the environmental problem. Laboratory-based waste centrifuge tubes made of polypropylene were chosen as a carbon source to show the process principle. In the process, multi-walled carbon nanotubes (MWCNTs were synthesized from plastic waste in a two-stage stainless steel 316 (SS 316 metal tube that acted as both reactor vessel and catalyst. The steel reactor contains Fe (and Ni, and various alloys, which act as the catalyst for the carbon conversion process. The reaction and products were studied using electron probe microanalysis, thermogravimetric analysis, Raman spectroscopy and transmission electron microscopy and scanning electron microscopy. Optimization studies to determine the effect of different parameters on the process showed that the highest yield and most graphitized MWCNTs were formed at 900 °C under the reaction conditions used (yield 42%; Raman ID/IG ratio = 0.48. The high quality and high yield of the MWCNTs that were produced in a flow reactor from plastic waste using a two stage SS 316 chemical vapor deposition (CVD furnace did not require the use of an added catalyst.

  13. Multi-Objective Thermo-Economic Optimization Strategy for ORCs Applied to Subcritical and Transcritical Cycles for Waste Heat Recovery

    Directory of Open Access Journals (Sweden)

    Steven Lecompte

    2015-04-01

    Full Text Available Organic Rankine cycles (ORCs are an established technology to convert waste heat to electricity. Although several commercial implementations exist, there is still considerable potential for thermo-economic optimization. As such, a novel framework for designing optimized ORC systems is proposed based on a multi-objective optimization scheme in combination with financial appraisal in a post-processing step. The suggested methodology provides the flexibility to quickly assess several economic scenarios and this without the need of knowing the complex design procedure. This novel way of optimizing and interpreting results is applied to a waste heat recovery case. Both the transcritical ORC and subcritical ORC are investigated and compared using the suggested optimization strategy.

  14. Estimation of residual MSW heating value as a function of waste component recycling

    International Nuclear Information System (INIS)

    Magrinho, Alexandre; Semiao, Viriato

    2008-01-01

    Recycling of packaging wastes may be compatible with incineration within integrated waste management systems. To study this, a mathematical model is presented to calculate the fraction composition of residual municipal solid waste (MSW) only as a function of the MSW fraction composition at source and recycling fractions of the different waste materials. The application of the model to the Lisbon region yielded results showing that the residual waste fraction composition depends both on the packaging wastes fraction at source and on the ratio between that fraction and the fraction of the same material, packaging and non-packaging, at source. This behaviour determines the variation of the residual waste LHV. For 100% of paper packaging recycling, LHV reduces 4.2% whereas this reduction is of 14.4% for 100% of packaging plastics recycling. For 100% of food waste recovery, LHV increases 36.8% due to the moisture fraction reduction of the residual waste. Additionally the results evidence that the negative impact of recycling paper and plastic packaging on the LHV may be compensated by recycling food waste and glass and metal packaging. This makes packaging materials recycling and food waste recovery compatible strategies with incineration within integrated waste management systems

  15. NWTS program criteria for mined geologic disposal of nuclear waste: functional requirements and performance criteria for waste packages for solidified high-level waste and spent fuel

    International Nuclear Information System (INIS)

    1982-07-01

    The Department of Energy (DOE) has primary federal responsibility for the development and implementation of safe and environmentally acceptable nuclear waste disposal methods. Currently, the principal emphasis in the program is on emplacement of nuclear wastes in mined geologic repositories well beneath the earth's surface. A brief description of the mined geologic disposal system is provided. The National Waste Terminal Storage (NWTS) program was established under DOE's predecessor, the Energy Research and Development Administration, to provide facilities for the mined geologic disposal of radioactive wastes. The NWTS program includes both the development and the implementation of the technology necessary for designing, constructing, licensing, and operating repositories. The program does not include the management of processing radioactive wastes or of transporting the wastes to repositories. The NWTS-33 series, of which this document is a part, provides guidance for the NWTS program in the development and implementation of licensed mined geologic disposal systems for solidified high-level and transuranic (TRU) wastes. This document presents the functional requirements and performance criteria for waste packages for solidified high-level waste and spent fuel. A separate document to be developed, NWTS-33(4b), will present the requirements and criteria for waste packages for TRU wastes. The hierarchy and application of these requirements and criteria are discussed in Section 2.2

  16. Tank waste remediation system functions and requirements document

    Energy Technology Data Exchange (ETDEWEB)

    Carpenter, K.E

    1996-10-03

    This is the Tank Waste Remediation System (TWRS) Functions and Requirements Document derived from the TWRS Technical Baseline. The document consists of several text sections that provide the purpose, scope, background information, and an explanation of how this document assists the application of Systems Engineering to the TWRS. The primary functions identified in the TWRS Functions and Requirements Document are identified in Figure 4.1 (Section 4.0) Currently, this document is part of the overall effort to develop the TWRS Functional Requirements Baseline, and contains the functions and requirements needed to properly define the top three TWRS function levels. TWRS Technical Baseline information (RDD-100 database) included in the appendices of the attached document contain the TWRS functions, requirements, and architecture necessary to define the TWRS Functional Requirements Baseline. Document organization and user directions are provided in the introductory text. This document will continue to be modified during the TWRS life-cycle.

  17. Tank waste remediation system functions and requirements document

    International Nuclear Information System (INIS)

    Carpenter, K.E

    1996-01-01

    This is the Tank Waste Remediation System (TWRS) Functions and Requirements Document derived from the TWRS Technical Baseline. The document consists of several text sections that provide the purpose, scope, background information, and an explanation of how this document assists the application of Systems Engineering to the TWRS. The primary functions identified in the TWRS Functions and Requirements Document are identified in Figure 4.1 (Section 4.0) Currently, this document is part of the overall effort to develop the TWRS Functional Requirements Baseline, and contains the functions and requirements needed to properly define the top three TWRS function levels. TWRS Technical Baseline information (RDD-100 database) included in the appendices of the attached document contain the TWRS functions, requirements, and architecture necessary to define the TWRS Functional Requirements Baseline. Document organization and user directions are provided in the introductory text. This document will continue to be modified during the TWRS life-cycle

  18. How were Neolithic ditches filled in? Deposition study of two enclosures from Bohemia

    Czech Academy of Sciences Publication Activity Database

    Řídký, Jaroslav; Končelová, Markéta; Šumberová, Radka; Limburský, Petr; Květina, Petr

    2014-01-01

    Roč. 17, č. 4 (2014), s. 579-601 ISSN 1461-9571 R&D Projects: GA ČR(CZ) GAP405/11/1590 Institutional support: RVO:67985912 Keywords : Late Neolithic * Central Europe * circular enclosures * rondels * formation processes * deposition Subject RIV: AC - Archeology, Anthropology, Ethnology

  19. Modelling of Multi Input Transfer Function for Rainfall Forecasting in Batu City

    Directory of Open Access Journals (Sweden)

    Priska Arindya Purnama

    2017-11-01

    Full Text Available The aim of this research is to model and forecast the rainfall in Batu City using multi input transfer function model based on air temperature, humidity, wind speed and cloud. Transfer function model is a multivariate time series model which consists of an output series (Yt sequence expected to be effected by an input series (Xt and other inputs in a group called a noise series (Nt. Multi input transfer function model obtained is (b1,s1,r1 (b2,s2,r2 (b3,s3,r3 (b4,s4,r4(pn,qn = (0,0,0 (23,0,0 (1,2,0 (0,0,0 ([5,8],2 and shows that air temperature on t-day affects rainfall on t-day, rainfall on t-day is influenced by air humidity in the previous 23 days, rainfall on t-day is affected by wind speed in the previous day , and rainfall on day t is affected by clouds on day t. The results of rainfall forecasting in Batu City with multi input transfer function model can be said to be accurate, because it produces relatively small RMSE value. The value of RMSE data forecasting training is 7.7921 while forecasting data testing is 4.2184. Multi-input transfer function model is suitable for rainfall in Batu City.

  20. Efficacy of Pseudomonas fluorescens strain CL145A spray dried powder for controlling zebra mussels adhering to native unionid mussels within field enclosures

    Science.gov (United States)

    Luoma, James A.; Weber, Kerry L.; Severson, Todd J.; Mayer, Denise A.

    2015-01-01

    The efficacy of a commercially prepared spray dried powder (SDP) formulation of Pseudomonas fluorescens (strain CL145A) was evaluated for removing zebra mussels (Dreissena polymorpha) adhering to a population of unionid mussels in Lake Darling (Alexandria, Minnesota). Two groups of unionid mussels were used in the study. Unionid mussels were collected near the test area, weighed, photographed, individually tagged, and randomly allocated to one of nine test enclosures in equal proportions and then divided into two groups. The first group of unionid mussels (Group 1, n = 5 per test enclosure) were indiscriminately selected from each test enclosure and used to estimate the number of zebra mussels adhering to unionid mussels prior to exposure. The second group of unionid mussels (Group 2, n = 22 per test enclosure) were used to evaluate the efficacy of SDP for removal of adhering zebra mussels. Both Group 1 and Group 2 mussels were used to evaluate the effects of SDP exposure on unionid mussel survival.

  1. Mixed convection flow of nanofluid in a square enclosure with an intruded rectangular fin

    International Nuclear Information System (INIS)

    Cong, Ran; Zhou, Xuanyu; De Souza Machado, Bruno; Das, Prodip K.

    2016-01-01

    Mixed convection flow in enclosures has been a subject of interest for many years due to their ever increasing applications in solar collectors, electronic cooling, lubrication technologies, food processing, and nuclear reactors. In comparison, little effort has been given to the problem of mixed convection in enclosures filled with nanofluids, while the addition of nanoparticles in a fluid base to alter specific material properties is considered a feasible solution for many heat transfer problems. Mixed convection of nanofluids is a challenging problem as the addition of nanoparticles changes the fluid’s thermo-physical properties as well as due to the complex interactions among inertia, viscous, and buoyancy forces. In this study, a two-dimensional steady-state numerical model has been developed to investigate mixed convection flow of nanofluids in a square enclosure with an intruded rectangular fin and to optimize the fin geometry for maximizing the heat transfer using the Constructal design. The model has been developed using ANSYS-FLUENT for various fin geometries. Flow fields, temperature fields, and heat transfer rates are examined for different values of Rayleigh and Reynolds numbers for several geometries of the fin with the aim of maximizing the heat transfer from the fin to the surrounding flow. Outcome of this study provides important insight into the heat transfer behavior of nanofluids, which will help in developing novel geometries with enhanced and controlled heat transfer for solar collectors and electronic devices.

  2. Mixed convection flow of nanofluid in a square enclosure with an intruded rectangular fin

    Energy Technology Data Exchange (ETDEWEB)

    Cong, Ran; Zhou, Xuanyu; De Souza Machado, Bruno; Das, Prodip K., E-mail: prodip.das@ncl.ac.uk [School of Mechanical and Systems Engineering Newcastle University Newcastle upon Tyne, NE1 7RU United Kingdom (United Kingdom)

    2016-07-12

    Mixed convection flow in enclosures has been a subject of interest for many years due to their ever increasing applications in solar collectors, electronic cooling, lubrication technologies, food processing, and nuclear reactors. In comparison, little effort has been given to the problem of mixed convection in enclosures filled with nanofluids, while the addition of nanoparticles in a fluid base to alter specific material properties is considered a feasible solution for many heat transfer problems. Mixed convection of nanofluids is a challenging problem as the addition of nanoparticles changes the fluid’s thermo-physical properties as well as due to the complex interactions among inertia, viscous, and buoyancy forces. In this study, a two-dimensional steady-state numerical model has been developed to investigate mixed convection flow of nanofluids in a square enclosure with an intruded rectangular fin and to optimize the fin geometry for maximizing the heat transfer using the Constructal design. The model has been developed using ANSYS-FLUENT for various fin geometries. Flow fields, temperature fields, and heat transfer rates are examined for different values of Rayleigh and Reynolds numbers for several geometries of the fin with the aim of maximizing the heat transfer from the fin to the surrounding flow. Outcome of this study provides important insight into the heat transfer behavior of nanofluids, which will help in developing novel geometries with enhanced and controlled heat transfer for solar collectors and electronic devices.

  3. Construction of 3.6m ARIES telescope enclosure with eccentric pier at Devasthal, Nainital

    Science.gov (United States)

    Bangia, Tarun

    Space optimized enclosure with eccentric pier for 3.6m ARIES telescope presents construction challenges at the unique observing site of Devasthal, Nainital, India. Enclosure comprises of about 16.5m diameter and 14m high insulated steel framed cylindrical dome rotating on a 14m high stationery dome supporting structure and a 24m × 12m extension structure building for accommodating aluminizing plant and ventilation system etc. Great deal of manual and mechanical excavation was carried out at the rocky site using rock breaking and JCB machines. Foundation bolts for columns of dome supporting structure and extension structure building were grouted after alignment with total station. A 7m diameter hollow cylindrical pier isolated from other structures and 1.85m eccentric with dome center designed due to space limitation at site is being casted for mounting 150 MT mass of the largest 3.6m telescope in the country. A 7m diameter template was fabricated for 3.6m pier top. Most of enclosure components are manufactured and tested in works before assembly/erection at site. Dome drive was tested with dummy loads using VVVF drive with 6 drive and 12 idler wheel assemblies at works to simulate dome weight and smooth operation before erection at site. A 4.2m wide motorized windscreen is being manufactured with a special grade synthetic fabric to withstand wind speed up to 15m/s.

  4. Mixed convection flow of nanofluid in a square enclosure with an intruded rectangular fin

    Science.gov (United States)

    Cong, Ran; Zhou, Xuanyu; De Souza Machado, Bruno; Das, Prodip K.

    2016-07-01

    Mixed convection flow in enclosures has been a subject of interest for many years due to their ever increasing applications in solar collectors, electronic cooling, lubrication technologies, food processing, and nuclear reactors. In comparison, little effort has been given to the problem of mixed convection in enclosures filled with nanofluids, while the addition of nanoparticles in a fluid base to alter specific material properties is considered a feasible solution for many heat transfer problems. Mixed convection of nanofluids is a challenging problem as the addition of nanoparticles changes the fluid's thermo-physical properties as well as due to the complex interactions among inertia, viscous, and buoyancy forces. In this study, a two-dimensional steady-state numerical model has been developed to investigate mixed convection flow of nanofluids in a square enclosure with an intruded rectangular fin and to optimize the fin geometry for maximizing the heat transfer using the Constructal design. The model has been developed using ANSYS-FLUENT for various fin geometries. Flow fields, temperature fields, and heat transfer rates are examined for different values of Rayleigh and Reynolds numbers for several geometries of the fin with the aim of maximizing the heat transfer from the fin to the surrounding flow. Outcome of this study provides important insight into the heat transfer behavior of nanofluids, which will help in developing novel geometries with enhanced and controlled heat transfer for solar collectors and electronic devices.

  5. Design of Smart Multi-Functional Integrated Aviation Photoelectric Payload

    Science.gov (United States)

    Zhang, X.

    2018-04-01

    To coordinate with the small UAV at reconnaissance mission, we've developed a smart multi-functional integrated aviation photoelectric payload. The payload weighs only 1kg, and has a two-axis stabilized platform with visible task payload, infrared task payload, laser pointers and video tracker. The photoelectric payload could complete the reconnaissance tasks above the target area (including visible and infrared). Because of its light weight, small size, full-featured, high integrated, the constraints of the UAV platform carrying the payload will be reduced a lot, which helps the payload suit for more extensive using occasions. So all users of this type of smart multi-functional integrated aviation photoelectric payload will do better works on completion of the ground to better pinpoint targets, artillery calibration, assessment of observe strike damage, customs officials and other tasks.

  6. Development of multi-functional combine harvester with grain harvesting and straw baling

    International Nuclear Information System (INIS)

    Tang, Z.; Li, Y.; Cheng, C.

    2017-01-01

    The decomposition and burning of straw results in serious environmental pollution, and research is needed to improve strategies for straw collection to reduce pollution. This work presents an integrated design of multi-functional rice combine harvester that allows grain harvesting and straw baling. This multi-functional combine harvester could reduce the energy consumption required for rice harvesting and simplify the process of harvesting and baling. The transmission schematic, matching parameters and the rotation speed of threshing cylinder and square baler were designed and checked. Then the evaluation of grain threshing and straw baling were tested on a transverse threshing cylinders device tes rig and straw square bales compression test rig. The test results indicated that, with a feeding rate of 3.0 kg/s, the remaining straw flow rate at the discharge outlet was only 1.22 kg/s, which indicates a variable mass threshing process by the transverse threshing cylinder. Then the optimal diameter, length and rotating speed of multi-functional combine harvester transverse threshing cylinder were 554 mm, 1590 mm, and 850 r/min, respectively. The straw bale compression rotating speed of crank compression slider and piston was 95 r/min. Field trials by the multi-functional combine harvester formed bales with height×width×length of 40×50×54-63 cm, bale mass of 22.5 to 26.0 kg and bale density 206 to 216 kg/m3. This multi-functional combine harvester could be used for stem crops (such as rice, wheat and soybean) grain harvesting and straw square baling, which could reduce labor cost and power consumption.

  7. Development of multi-functional combine harvester with grain harvesting and straw baling

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Z.; Li, Y.; Cheng, C.

    2017-09-01

    The decomposition and burning of straw results in serious environmental pollution, and research is needed to improve strategies for straw collection to reduce pollution. This work presents an integrated design of multi-functional rice combine harvester that allows grain harvesting and straw baling. This multi-functional combine harvester could reduce the energy consumption required for rice harvesting and simplify the process of harvesting and baling. The transmission schematic, matching parameters and the rotation speed of threshing cylinder and square baler were designed and checked. Then the evaluation of grain threshing and straw baling were tested on a transverse threshing cylinders device tes rig and straw square bales compression test rig. The test results indicated that, with a feeding rate of 3.0 kg/s, the remaining straw flow rate at the discharge outlet was only 1.22 kg/s, which indicates a variable mass threshing process by the transverse threshing cylinder. Then the optimal diameter, length and rotating speed of multi-functional combine harvester transverse threshing cylinder were 554 mm, 1590 mm, and 850 r/min, respectively. The straw bale compression rotating speed of crank compression slider and piston was 95 r/min. Field trials by the multi-functional combine harvester formed bales with height×width×length of 40×50×54-63 cm, bale mass of 22.5 to 26.0 kg and bale density 206 to 216 kg/m3. This multi-functional combine harvester could be used for stem crops (such as rice, wheat and soybean) grain harvesting and straw square baling, which could reduce labor cost and power consumption.

  8. Using multi-criteria decision making for selection of the optimal strategy for municipal solid waste management.

    Science.gov (United States)

    Jovanovic, Sasa; Savic, Slobodan; Jovicic, Nebojsa; Boskovic, Goran; Djordjevic, Zorica

    2016-09-01

    Multi-criteria decision making (MCDM) is a relatively new tool for decision makers who deal with numerous and often contradictory factors during their decision making process. This paper presents a procedure to choose the optimal municipal solid waste (MSW) management system for the area of the city of Kragujevac (Republic of Serbia) based on the MCDM method. Two methods of multiple attribute decision making, i.e. SAW (simple additive weighting method) and TOPSIS (technique for order preference by similarity to ideal solution), respectively, were used to compare the proposed waste management strategies (WMS). Each of the created strategies was simulated using the software package IWM2. Total values for eight chosen parameters were calculated for all the strategies. Contribution of each of the six waste treatment options was valorized. The SAW analysis was used to obtain the sum characteristics for all the waste management treatment strategies and they were ranked accordingly. The TOPSIS method was used to calculate the relative closeness factors to the ideal solution for all the alternatives. Then, the proposed strategies were ranked in form of tables and diagrams obtained based on both MCDM methods. As shown in this paper, the results were in good agreement, which additionally confirmed and facilitated the choice of the optimal MSW management strategy. © The Author(s) 2016.

  9. How to handle a Huygens' box inside an enclosure

    DEFF Research Database (Denmark)

    Sørensen, Morten; Bonev, Ivan Bonev; Franek, Ondrej

    2013-01-01

    It has been suggested that it is possible to replace printed circuit boards with a Huygens' box (HB) representation obtained from a near-field scan in simulation of far-fields from an apparatus. However, the surface equivalence theorem requires that the environment outside HB is the same in the n...... caused by violating the surface equivalence theorem can be lower than 2 dB. It is also demonstrated that if the printed circuit board is galvanically connected to the enclosure, the near-field scan must be performed under same conditions....

  10. Analysis of a multi-frequency electromagnetic imaging functional for thin, crack-like electromagnetic inclusions

    OpenAIRE

    Park, Won-Kwang

    2012-01-01

    Recently, a non-iterative multi-frequency subspace migration imaging algorithm was developed based on an asymptotic expansion formula for thin, curve-like electromagnetic inclusions and the structure of singular vectors in the Multi-Static Response (MSR) matrix. The present study examines the structure of subspace migration imaging functional and proposes an improved imaging functional weighted by the frequency. We identify the relationship between the imaging functional and Bessel functions ...

  11. Numerical simulation of thermomagnetic convection of cold water near its density maximum in a square enclosure under a magnetic quadrupole field

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Er; Sun, Xiaoqin; He, Yecong; Jiang, Changwei, E-mail: cw_jiang@163.com [School of Energy and Power Engineering, Changsha University of Science and Technology, Changsha 410114 (China)

    2017-06-15

    Natural convection of cold water near its density maximum in a square enclosure is studied numerically under the influence of a magnetic quadrupole field without gravity. A generalized model which includes a non-Boussinesq parabolic density–temperature relationship is established. The governing equations in primitive variables are discretized using the finite-volume method and solved using the SIMPLE algorithm. The effects of magnetic force number, Rayleigh number and density inversion parameter on flow and heat transfer characteristics are analyzed. The results show that the primary flow pattern depends mainly on the density inversion parameter. Multi-cellular flow structures are observed for certain ranges of density inversion parameter independent of the value of Rayleigh number and magnetic force number. The heat transfer changes non-monotonically under combined actions of the quadrupole magnetic field and density inversion. (paper)

  12. Some ecological implications of a neem (azadirachtin) insecticide disturbance to zooplankton communities in forest pond enclosures.

    Science.gov (United States)

    Kreutzweiser, David P; Sutton, Trent M; Back, Richard C; Pangle, Kevin L; Thompson, Dean G

    2004-04-28

    A neem-based insecticide, Neemix 4.5, was applied to forest pond enclosures at concentrations of 10, 17, and 28 microg l(-1) azadirachtin (the active ingredient). At these test concentrations, significant, concentration-dependent reductions in numbers of adult copepods were observed, but immature copepod and cladoceran populations were unaffected. There was no evidence of recovery of adult copepods within the sampling season (May to October). The ecological significance of this disturbance to the zooplankton community was examined by determining biomass as a measure of food availability for higher predators, plankton community respiration, dissolved oxygen (DO) concentrations, and conductivity as functional indicators of ecosystem stress, and zooplankton food web stability as a measure of effects on trophic structure. The selective removal or reduction of adult copepods was sufficient to measurably reduce total zooplankton biomass for several weeks mid-season. During the period of maximal impact (about 4-9 weeks after the applications), total plankton community respiration was significantly reduced, and this appeared to contribute to significant, concentration-dependent increases in dissolved oxygen and decreases in conductivity among treated enclosures. The reductions in adult copepods resulted in negative effects on zooplankton food web stability through eliminations of a trophic link and reduced interactions and connectance. Comparing the results here to those from a previous study with tebufenozide, which was selectively toxic to cladocerans and had little effect on food web stability, indicates that differential sensitivity among taxa can influence the ecological significance of pesticide effects on zooplankton communities.

  13. Multi-configuration time-dependent density-functional theory based on range separation

    DEFF Research Database (Denmark)

    Fromager, E.; Knecht, S.; Jensen, Hans Jørgen Aagaard

    2013-01-01

    Multi-configuration range-separated density-functional theory is extended to the time-dependent regime. An exact variational formulation is derived. The approximation, which consists in combining a long-range Multi-Configuration- Self-Consistent Field (MCSCF) treatment with an adiabatic short...... (srGGA) approximations. As expected, when modeling long-range interactions with the MCSCF model instead of the adiabatic Buijse-Baerends density-matrix functional as recently proposed by Pernal [J. Chem. Phys. 136, 184105 (2012)10.1063/1.4712019], the description of both the 1D doubly-excited state...

  14. Safeguards considerations related to the use of multi-purpose canisters in the Civilian Radioactive Waste Management system

    International Nuclear Information System (INIS)

    Floyd, W.C.

    1995-01-01

    The US Department of Energy's (DOE) Office of Civilian Radioactive Waste Management (OCRWM) is responsible for disposing of the nation's high-level radioactive waste. Currently, DOE is considering the use of Multi-Purpose Canisters (MPCs) to containerize commercial spent nuclear fuel (SNF) to be handled by the system. To achieve its safeguards and security objectives, OCRWM plans to institute a US Regulatory Commission (NRC)-approved safeguards program. Since the Mined Geologic Disposal System (MGDS) facility and a possible Monitored Retrievable Storage (MRS) facility may be subject to selection for International Atomic Energy Agency (IAEA) inspections, the safeguards program for MPCs may not preclude compliance with the requirements of the IAEA's Annex D, Special Criteria for Difficult-to-Access Fuel Items. MPC safeguards are based on three principles: Verification, Material Control and Accounting, and Physical Protection

  15. Multi-function radar emitter identification based on stochastic syntax-directed translation schema

    OpenAIRE

    Liu, Haijun; Yu, Hongqi; Sun, Zhaolin; Diao, Jietao

    2014-01-01

    To cope with the problem of emitter identification caused by the radar words’ uncertainty of measured multi-function radar emitters, this paper proposes a new identification method based on stochastic syntax-directed translation schema (SSDTS). This method, which is deduced from the syntactic modeling of multi-function radars, considers the probabilities of radar phrases appearance in different radar modes as well as the probabilities of radar word errors occurrence in different radar phrases...

  16. Interactive Preference Learning of Utility Functions for Multi-Objective Optimization

    OpenAIRE

    Dewancker, Ian; McCourt, Michael; Ainsworth, Samuel

    2016-01-01

    Real-world engineering systems are typically compared and contrasted using multiple metrics. For practical machine learning systems, performance tuning is often more nuanced than minimizing a single expected loss objective, and it may be more realistically discussed as a multi-objective optimization problem. We propose a novel generative model for scalar-valued utility functions to capture human preferences in a multi-objective optimization setting. We also outline an interactive active learn...

  17. Multi-criteria evaluation in strategic environmental assessment for waste management plan, a case study: the city of Belgrade.

    Science.gov (United States)

    Josimović, Boško; Marić, Igor; Milijić, Saša

    2015-02-01

    Strategic Environmental Assessment (SEA) is one of the key instruments for implementing sustainable development strategies in planning in general; in addition to being used in sectoral planning, it can also be used in other areas such as waste management planning. SEA in waste management planning has become a tool for considering the benefits and consequences of the proposed changes in space, also taking into account the capacity of space to sustain the implementation of the planned activities. In order to envisage both the positive and negative implications of a waste management plan for the elements of sustainable development, an adequate methodological approach to evaluating the potential impacts must be adopted and the evaluation results presented in a simple and clear way, so as to allow planners to make relevant decisions as a precondition for the sustainability of the activities planned in the waste management sector. This paper examines the multi-criteria evaluation method for carrying out an SEA for the Waste Management Plan for the city of Belgrade (BWMP). The method was applied to the evaluation of the impacts of the activities planned in the waste management sector on the basis of the environmental and socioeconomic indicators of sustainability, taking into consideration the intensity, spatial extent, probability and frequency of impact, by means of a specific planning approach and simple and clear presentation of the obtained results. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Life cycle environmental impacts of different construction wood waste and wood packaging waste processing methods

    OpenAIRE

    Manninen, Kaisa; Judl, Jáchym; Myllymaa, Tuuli

    2016-01-01

    This study compared the life cycle environmental impacts of different wood waste processing methods in three impact categories: climate impact, acidification impacts and eutrophication impacts. The wood waste recovery methods examined were the use of wood waste in terrace boards made out of wood composite which replace impregnated terrace boards, incineration of wood waste in a multi-fuel boiler instead of peat and the use of wood waste in the production of particleboard in either Finland or ...

  19. Radiation exchange factors between specular inner surfaces of a rectangular enclosure such as transplant production unit

    International Nuclear Information System (INIS)

    Abdel-Ghany, Ahmed M.; Kozai, Toyoki

    2006-01-01

    General mathematical relations are presented for the specular exchange factors, F S , of diffuse radiation exchange between the inner surfaces of a rectangular enclosure. Three of these surfaces are specular reflectors, diffuse emitters and the fourth surface is a diffuse reflector, diffuse emitter. This enclosure can be used as a transplant production unit with artificial lighting for electric energy saving purposes. An image system and the crossed string method are used to derive these relations. The resulting expressions are conceptually simple and similar to the commonly known expressions of the exchange factors between diffuse surfaces, F. The accuracy of the presented F S relations was examined for different numbers of multiple reflections, N, on the specular surfaces and for different aspect ratios (ratio of the width, w to the height, h). The results proved that the relations are accurate and strongly satisfy the well-known relation of the radiation exchange between enclosure surfaces and satisfy the reciprocity relation. For any aspect ratio, considering N of 150 between highly reflective surfaces (ρ = 0.99) is sufficient to estimate the F S factors without any possible error. Using specular reflecting surfaces in such cases significantly reduces the electric energy consumption used for lighting

  20. Topological characteristics of multi-valued maps and Lipschitzian functionals

    International Nuclear Information System (INIS)

    Klimov, V S

    2008-01-01

    This paper deals with the operator inclusion O element of F(x)+N Q (x), where F is a multi-valued map of monotonic type from a reflexive space V to its conjugate V * and N Q is the cone normal to the closed set Q, which, generally speaking, is not convex. To estimate the number of solutions of this inclusion we introduce topological characteristics of multi-valued maps and Lipschitzian functionals that have the properties of additivity and homotopy invariance. We prove some infinite-dimensional versions of the Poincare-Hopf theorem

  1. Natural convection in square enclosure induced by inner circular cylinder with time-periodic pulsating temperature

    KAUST Repository

    Huang, Zhu; Zhang, Wei; Xi, Guang

    2015-01-01

    The periodic unsteady natural convection flow and heat transfer in a square enclosure containing a concentric circular cylinder is numerically studied. The temperature of the inner circular cylinder fluctuates periodically with time at higher

  2. Multi-trace element levels and arsenic speciation in urine of e-waste recycling workers from Agbogbloshie, Accra in Ghana

    International Nuclear Information System (INIS)

    Asante, Kwadwo Ansong; Agusa, Tetsuro; Biney, Charles Augustus; Agyekum, William Atuobi; Bello, Mohammed; Otsuka, Masanari; Itai, Takaaki; Takahashi, Shin; Tanabe, Shinsuke

    2012-01-01

    To understand human contamination by multi-trace elements (TEs) in electrical and electronic waste (e-waste) recycling site at Agbogbloshie, Accra in Ghana, this study analyzed TEs and As speciation in urine of e-waste recycling workers. Concentrations of Fe, Sb, and Pb in urine of e-waste recycling workers were significantly higher than those of reference sites after consideration of interaction by age, indicating that the recycling workers are exposed to these TEs through the recycling activity. Urinary As concentration was relatively high, although the level in drinking water was quite low. Speciation analysis of As in human urine revealed that arsenobetaine and dimethylarsinic acid were the predominant As species and concentrations of both species were positively correlated with total As concentration as well as between each other. These results suggest that such compounds may be derived from the same source, probably fish and shellfish and greatly influence As exposure levels. To our knowledge, this is the first study on human contamination resulting from the primitive recycling of e-waste in Ghana. This study will contribute to the knowledge about human exposure to trace elements from an e-waste site in a less industrialized region so far scantly covered in the literature. - Highlights: ► Exposure status of trace elements in e-waste recycling workers was assessed in Ghana. ► Concentrations of Fe, Sb, and Pb in urine of e-waste workers were significantly higher than those of the reference subjects. ► This study is the first to investigate human contamination arising from primitive recycling of e-waste arguably from Africa.

  3. Multi-trace element levels and arsenic speciation in urine of e-waste recycling workers from Agbogbloshie, Accra in Ghana

    Energy Technology Data Exchange (ETDEWEB)

    Asante, Kwadwo Ansong [Center for Marine Environmental Studies (CMES), Ehime University, Bunkyo-cho 2-5, Matsuyama 790-8577 (Japan); CSIR Water Research Institute, P. O. Box AH 38, Achimota, Accra (Ghana); Agusa, Tetsuro [Center for Marine Environmental Studies (CMES), Ehime University, Bunkyo-cho 2-5, Matsuyama 790-8577 (Japan); Biney, Charles Augustus [Volta Basin Authority (VBA), 10 P. O. Box 13621, Ouagadougou 10 (Burkina Faso); Agyekum, William Atuobi; Bello, Mohammed [CSIR Water Research Institute, P. O. Box AH 38, Achimota, Accra (Ghana); Otsuka, Masanari [Center for Marine Environmental Studies (CMES), Ehime University, Bunkyo-cho 2-5, Matsuyama 790-8577 (Japan); Ehime Prefectural Institute of Public Health and Environmental Science, 8-234 Sanban-cho, Matsuyama 790-0003 (Japan); Itai, Takaaki; Takahashi, Shin [Center for Marine Environmental Studies (CMES), Ehime University, Bunkyo-cho 2-5, Matsuyama 790-8577 (Japan); Tanabe, Shinsuke, E-mail: shinsuke@agr.ehime-u.ac.jp [Center for Marine Environmental Studies (CMES), Ehime University, Bunkyo-cho 2-5, Matsuyama 790-8577 (Japan)

    2012-05-01

    To understand human contamination by multi-trace elements (TEs) in electrical and electronic waste (e-waste) recycling site at Agbogbloshie, Accra in Ghana, this study analyzed TEs and As speciation in urine of e-waste recycling workers. Concentrations of Fe, Sb, and Pb in urine of e-waste recycling workers were significantly higher than those of reference sites after consideration of interaction by age, indicating that the recycling workers are exposed to these TEs through the recycling activity. Urinary As concentration was relatively high, although the level in drinking water was quite low. Speciation analysis of As in human urine revealed that arsenobetaine and dimethylarsinic acid were the predominant As species and concentrations of both species were positively correlated with total As concentration as well as between each other. These results suggest that such compounds may be derived from the same source, probably fish and shellfish and greatly influence As exposure levels. To our knowledge, this is the first study on human contamination resulting from the primitive recycling of e-waste in Ghana. This study will contribute to the knowledge about human exposure to trace elements from an e-waste site in a less industrialized region so far scantly covered in the literature. - Highlights: Black-Right-Pointing-Pointer Exposure status of trace elements in e-waste recycling workers was assessed in Ghana. Black-Right-Pointing-Pointer Concentrations of Fe, Sb, and Pb in urine of e-waste workers were significantly higher than those of the reference subjects. Black-Right-Pointing-Pointer This study is the first to investigate human contamination arising from primitive recycling of e-waste arguably from Africa.

  4. Report of conceptual design for TRU solid waste facilities adjacent to 200H Area: Savannah River Plant

    International Nuclear Information System (INIS)

    1978-02-01

    Facilities for consolidating Savannah River Plant solid transuranic (TRU) waste and placing in long-term safe, retrievable storage have been designed conceptually. A venture guidance appraisal of cost for the facilities has been prepared. The proposed site of the new processing area is adjacent to existing H Area facilities. The scopes of work comprising the conceptual design describe facilities for: exhuming high-level TRU waste from buried and pad-stored locations in the plant burial ground; opening, emptying, and sorting waste containers and their contents within shielded, regulated enclosures; volume-reducing the noncombustibles by physical processes and decontaminating the metal waste; burning combustibles; fixing the consolidated waste forms in a concrete matrix within a double-walled steel container; placing product containers in a retrievable surface storage facility adjacent to the existing plant burial ground; and maintaining accountability of all special nuclear materials. Processing, administration, and auxiliary service buildings are to be located adjacent to existing H Area facilities where certain power and waste liquid services will be shared

  5. Effective Ginzburg–Landau free energy functional for multi-band isotropic superconductors

    International Nuclear Information System (INIS)

    Grigorishin, Konstantin V.

    2016-01-01

    Highlights: • The intergradient coupling of order parameters in a two-band superconductor plays important role and cannot be neglected. • A two-band superconductor must be characterized with a single coherence length and a single Ginzburg–Landau parameter. • Type-1.5 superconductors are impossible. • The free energy functional for a multi-band superconductor can be reduced to the effective single-band Ginzburg–Landau functional. - Abstract: It has been shown that interband mixing of gradients of two order parameters (drag effect) in an isotropic bulk two-band superconductor plays important role – such a quantity of the intergradients coupling exists that the two-band superconductor is characterized with a single coherence length and a single Ginzburg–Landau (GL) parameter. Other quantities or neglecting of the drag effect lead to existence of two coherence lengths and dynamical instability due to violation of the phase relations between the order parameters. Thus so-called type-1.5 superconductors are impossible. An approximate method for solving of set of GL equations for a multi-band superconductor has been developed: using the result about the drag effect it has been shown that the free-energy functional for a multi-band superconductor can be reduced to the GL functional for an effective single-band superconductor.

  6. Multi-fidelity Gaussian process regression for prediction of random fields

    International Nuclear Information System (INIS)

    Parussini, L.; Venturi, D.; Perdikaris, P.; Karniadakis, G.E.

    2017-01-01

    We propose a new multi-fidelity Gaussian process regression (GPR) approach for prediction of random fields based on observations of surrogate models or hierarchies of surrogate models. Our method builds upon recent work on recursive Bayesian techniques, in particular recursive co-kriging, and extends it to vector-valued fields and various types of covariances, including separable and non-separable ones. The framework we propose is general and can be used to perform uncertainty propagation and quantification in model-based simulations, multi-fidelity data fusion, and surrogate-based optimization. We demonstrate the effectiveness of the proposed recursive GPR techniques through various examples. Specifically, we study the stochastic Burgers equation and the stochastic Oberbeck–Boussinesq equations describing natural convection within a square enclosure. In both cases we find that the standard deviation of the Gaussian predictors as well as the absolute errors relative to benchmark stochastic solutions are very small, suggesting that the proposed multi-fidelity GPR approaches can yield highly accurate results.

  7. Multi-fidelity Gaussian process regression for prediction of random fields

    Energy Technology Data Exchange (ETDEWEB)

    Parussini, L. [Department of Engineering and Architecture, University of Trieste (Italy); Venturi, D., E-mail: venturi@ucsc.edu [Department of Applied Mathematics and Statistics, University of California Santa Cruz (United States); Perdikaris, P. [Department of Mechanical Engineering, Massachusetts Institute of Technology (United States); Karniadakis, G.E. [Division of Applied Mathematics, Brown University (United States)

    2017-05-01

    We propose a new multi-fidelity Gaussian process regression (GPR) approach for prediction of random fields based on observations of surrogate models or hierarchies of surrogate models. Our method builds upon recent work on recursive Bayesian techniques, in particular recursive co-kriging, and extends it to vector-valued fields and various types of covariances, including separable and non-separable ones. The framework we propose is general and can be used to perform uncertainty propagation and quantification in model-based simulations, multi-fidelity data fusion, and surrogate-based optimization. We demonstrate the effectiveness of the proposed recursive GPR techniques through various examples. Specifically, we study the stochastic Burgers equation and the stochastic Oberbeck–Boussinesq equations describing natural convection within a square enclosure. In both cases we find that the standard deviation of the Gaussian predictors as well as the absolute errors relative to benchmark stochastic solutions are very small, suggesting that the proposed multi-fidelity GPR approaches can yield highly accurate results.

  8. Reconstruction of Sound Source Pressures in an Enclosure Using the Phased Beam Tracing Method

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho; Ih, Jeong-Guon

    2009-01-01

    . First, surfaces of an extended source are divided into reasonably small segments. From each source segment, one beam is projected into the field and all emitted beams are traced. Radiated beams from the source reach array sensors after traveling various paths including the wall reflections. Collecting...... all the pressure histories at the field points, source-observer relations can be constructed in a matrix-vector form for each frequency. By multiplying the measured field data with the pseudo-inverse of the calculated transfer function, one obtains the distribution of source pressure. An omni......-directional sphere and a cubic source in a rectangular enclosure were taken as examples in the simulation tests. A reconstruction error was investigated by Monte Carlo simulation in terms of field point locations. When the source information was reconstructed by the present method, it was shown that the sound power...

  9. Managing plastic waste in East Africa: Niche innovations in plastic production and solid waste

    NARCIS (Netherlands)

    Ombis, L.O.; Vliet, van B.J.M.; Mol, A.P.J.

    2015-01-01

    This paper assesses the uptake of environmental innovation practices to cope with plastic waste in Kenyan urban centres at the interface of solid waste management and plastic production systems. The Multi Level Perspective on Technological Transitions is used to evaluate 7 innovation pathways of

  10. Performance analysis of hybrid ground-coupled heat pump system with multi-functions

    International Nuclear Information System (INIS)

    You, Tian; Wang, Baolong; Wu, Wei; Shi, Wenxing; Li, Xianting

    2015-01-01

    Highlights: • The hybrid GCHP system with multi-functions is proposed. • The system maintains the soil temperature and heating reliability steady. • The multi-functional operation of HCUT can save more energy of the system. - Abstract: Underground thermal imbalance is a significant problem for ground-coupled heat pump (GCHP) systems that serve predominately heated buildings in cold regions, which extract more heat from the ground and inject less heat, especially in buildings requiring domestic hot water (DHW). To solve this problem, a previously developed heat compensation unit with thermosyphon (HCUT) is integrated with a GCHP unit to build a hybrid GCHP system. To improve the energy savings of this hybrid GCHP system, the HCUT unit is set to have multiple functions (heat compensation, direct DHW and direct space heating) in this paper. To analyze the improved system performance, a hotel requiring air-conditioning and DHW is selected and simulated in three typical cold cities using the dynamic software DeST and TRNSYS. The results indicate that the hybrid GCHP system can maintain the underground thermal balance while keeping the indoor air temperature within the design range. Furthermore, the HCUT unit efficiently reduces the energy consumption via its multi-functional operations. Compared to the previous system that only used HCUT for heat compensation, adding the direct DHW function further saves 7.5–11.0% energy in heat compensation (HC) and DHW (i.e., 3.6–4.8% of the whole system). Simultaneously adding the direct DHW and space heating functions to the HCUT can save 9.8–12.9% energy in HC and DHW (i.e., 5.1–6.0% of the whole system). The hybrid GCHP system with a multi-functional HCUT provides more energy savings while maintaining the underground thermal balance in cold regions that demand both air-conditioning and DHW

  11. Optimum Design of Multi-Function Robot Arm Gripper for Varying Shape Green Product

    Directory of Open Access Journals (Sweden)

    Razali Zol Bahri

    2016-01-01

    Full Text Available The project focuses on thorough experimentally studies of the optimum design of Multi-function Robot Arm Gripper for varying shape green product. The purpose of this project is to design a few of robot arm gripper for multi-functionally grip a green product with varying shape. The main character of the gripper is that it can automated adjust its finger to suit with the shape of the product. An optimum design of multi-function robot arm gripper is verified through experimental study. The expected result is a series of analytical results on the proposal of gripper design and material that will be selected for the gripper. The analysis of the gripper design proposal by using ANSYS and CATIA software is described in detail in this paper.

  12. Numerical study of different conduction models for Al_2O_3-water nanofluid with variable properties inside a trapezoidal enclosure

    International Nuclear Information System (INIS)

    Arani, Ali Akbar Abbasian; Azemati, Ali Akbar; Rezaee, Mohammad; Hadavand, Behzad Shirkavand

    2017-01-01

    Natural convection in enclosures containing nanofluids is important in physical and environmental applications. Different models for conduction have been developed because of the importance of this phenomenon in natural convection in enclosures. In this study, effects of conduction models of Chon, Corcione, Khanafer, and Koo and Kleinstreuer on the natural convection inside a trapezoidal enclosure with hot and cold walls are evaluated numerically. The enclosure contains Al_2O_3-water nanofluid with variable properties. Effects of the conduction models on fluid flow, natural convection, variations in volume fraction, and diameter of nanoparticles in the models, as well as the variations in the Rayleigh number, are examined. Results show that at Rayleigh numbers of 105 and 106, the maximum and minimum values of the average Nusselt number are obtained using the models of Khanafer and Chon, respectively. In all models, the average Nusselt number presents upward and downward trends when the volume fraction of nanoparticles increases but decreases when the di- ameter of the nanoparticles increases. At Ra = 105 in all models, as the volume fraction of nanoparticles increases, the nanofluid provides a higher average Nusselt number compared with the base fluid. By contrast, at Ra = 106, at volume fractions larger than 0.01 and using the model of Chon, the average Nusselt number of the nanofluid is lower compared with that of the base fluid.

  13. multi scale analysis of a function by neural networks elementary derivatives functions

    International Nuclear Information System (INIS)

    Chikhi, A.; Gougam, A.; Chafa, F.

    2006-01-01

    Recently, the wavelet network has been introduced as a special neural network supported by the wavelet theory . Such networks constitute a tool for function approximation problems as it has been already proved in reference . Our present work deals with this model, treating a multi scale analysis of a function. We have then used a linear expansion of a given function in wavelets, neglecting the usual translation parameters. We investigate two training operations. The first one consists on an optimization of the output synaptic layer, the second one, optimizing the output function with respect to scale parameters. We notice a temporary merging of the scale parameters leading to some interesting results : new elementary derivatives units emerge, representing a new elementary task, which is the derivative of the output task

  14. Optical Multi-Gas Monitor Technology Demonstration on the International Space Station

    Science.gov (United States)

    Pilgrim, Jeffrey S.; Wood, William R.; Casias, Miguel E.; Vakhtin, Andrei B,; Johnson, Michael D.; Mudgett, Paul D.

    2014-01-01

    There are a variety of both portable and fixed gas monitors onboard the International Space Station (ISS). Devices range from rack-mounted mass spectrometers to hand-held electrochemical sensors. An optical Multi-Gas Monitor has been developed as an ISS Technology Demonstration to evaluate long-term continuous measurement of 4 gases. Based on tunable diode laser spectroscopy, this technology offers unprecedented selectivity, concentration range, precision, and calibration stability. The monitor utilizes the combination of high performance laser absorption spectroscopy with a rugged optical path length enhancement cell that is nearly impossible to misalign. The enhancement cell serves simultaneously as the measurement sampling cell for multiple laser channels operating within a common measurement volume. Four laser diode based detection channels allow quantitative determination of ISS cabin concentrations of water vapor (humidity), carbon dioxide, ammonia and oxygen. Each channel utilizes a separate vertical cavity surface emitting laser (VCSEL) at a different wavelength. In addition to measuring major air constituents in their relevant ranges, the multiple gas monitor provides real time quantitative gaseous ammonia measurements between 5 and 20,000 parts-per-million (ppm). A small ventilation fan draws air with no pumps or valves into the enclosure in which analysis occurs. Power draw is only about 3 W from USB sources when installed in Nanoracks or when connected to 28V source from any EXPRESS rack interface. Internal battery power can run the sensor for over 20 hours during portable operation. The sensor is controlled digitally with an FPGA/microcontroller architecture that stores data internally while displaying running average measurements on an LCD screen and interfacing with the rack or laptop via USB. Design, construction and certification of the Multi-Gas Monitor were a joint effort between Vista Photonics, Nanoracks and NASA-Johnson Space Center (JSC

  15. Magnetometric prospection of various types of large ditch enclosures (or fortifications) in Bohemia

    Czech Academy of Sciences Publication Activity Database

    Křivánek, Roman

    2003-01-01

    Roč. 41, - (2003), s. 216-219 ISSN 0066-5924. [Archaeological Prospection. Kraków, 10.09.2003-14.09.2003] R&D Projects: GA ČR GV404/97/K024 Institutional research plan: CEZ:AV0Z8002910 Keywords : ditch enclosure * magnetometric prospection * fortification Subject RIV: AC - Archeology, Anthropology, Ethnology

  16. Carbon Alloys-Multi-functionalization

    Energy Technology Data Exchange (ETDEWEB)

    Yasuda, Eiichi [MSL, Tokyo Institute of Technology, Yokohama 226-8503 (Japan)], E-mail: yasuda.e.aa.@m.titech.ac.jp; Enami, Takashi; Hoteida, Nobuyuki [MSL, Tokyo Institute of Technology, Yokohama 226-8503 (Japan); Lanticse-Diaz, L.J. [University of the Philippines (Philippines); Tanabe, Yasuhiro [Nagoya University (Japan); Akatsu, Takashi [MSL, Tokyo Institute of Technology, Yokohama 226-8503 (Japan)

    2008-02-25

    Last decade after our proposal of the 'Carbon Alloys' concept, many different kinds of Carbon Alloys, such as carbon nanotubes, carbon nanofibers, graphene sheet with magnetism, semi-conducting BCN compounds, graphite intercalation compounds, exfoliated carbon fiber, etc. have been found and developed. To extend the concept further, it is important to make it into intelligent materials by incorporating multiple functions. One example of the multi-functionalization is the development of homo-atomic Carbon Alloys from glassy carbon (GC) that exhibits high electrical conductivity and low gas permeability after treatment at critical conditions. Glassy carbon underwent metamorphosis to graphite spheres at HIP condition, and improved resistance to oxidation after alloying with Ta. The other one is shape utilization of the nano-sized carbon by understanding the effect of its large surfaces or interfaces in nanotechnology treatment. Recently carbon nanofiber was produced by polymer blend technology (PB) which was proposed by Prof. A. Oya during the Carbon Alloy project and progressed into intelligent carbon nanofiber (CNF) materials. CNF is combined into the polymer composites which is a candidate material for the bipolar separator in fuel cell. The superior properties, i.e., high electrical conductivity, high modulus, high strength, etc., of the CNF is being utilized in the preparation of this polymer composite.

  17. Lattice Boltzmann simulation of natural convection in an L-shaped enclosure in the presence of nanofluid

    Directory of Open Access Journals (Sweden)

    Bouchmel Mliki

    2015-09-01

    Full Text Available In the present paper, fluid flow and heat transfer inside L-shaped enclosure filled with Cu/water nanofluid has been investigated numerically using the Lattice Boltzmann Method. The validity of the numerical code used is ascertained and good agreement was found with published results. The effects of different parameters such as Rayleigh number (103–106, aspect ratio of the L-shaped enclosure (0.2–0.6 and nanoparticle volume concentration (0–0.05 on the flow and temperature fields are studied. The obtained results show that nanofluid enhances the heat transfer amount and reducing the aspect ratio improves this effect. Also it was found that the mean Nusselt number increased with increase in Rayleigh number.

  18. Effect of amino acid-functionalized multi-walled carbon nanotubes ...

    Indian Academy of Sciences (India)

    In a single-step, rapid microwave-assisted process, multi-walled carbon nanotubes were functionalized by -valine amino acid. Formation of amino acid on nanotube surface was confirmed by Fourier transform-infrared spectroscopy, thermogravimetric analysis, X-ray diffraction, field emission scanning and transmission ...

  19. Modelling of Multi Input Transfer Function for Rainfall Forecasting in Batu City

    OpenAIRE

    Priska Arindya Purnama

    2017-01-01

    The aim of this research is to model and forecast the rainfall in Batu City using multi input transfer function model based on air temperature, humidity, wind speed and cloud. Transfer function model is a multivariate time series model which consists of an output series (Yt) sequence expected to be effected by an input series (Xt) and other inputs in a group called a noise series (Nt). Multi input transfer function model obtained is (b1,s1,r1) (b2,s2,r2) (b3,s3,r3) (b4,s4,r4)(pn,qn) = (0,0,0)...

  20. Electronic waste management approaches: An overview

    Energy Technology Data Exchange (ETDEWEB)

    Kiddee, Peeranart [Centre for Environmental Risk Assessment and Remediation, University of South Australia, Mawson Lakes Campus, Adelaide, SA 5095 (Australia); Cooperative Research Centre for Contamination Assessment and Remediation of the Environment, Mawson Lakes Campus, Adelaide, SA 5095 (Australia); Naidu, Ravi, E-mail: ravi.naidu@crccare.com [Centre for Environmental Risk Assessment and Remediation, University of South Australia, Mawson Lakes Campus, Adelaide, SA 5095 (Australia); Cooperative Research Centre for Contamination Assessment and Remediation of the Environment, Mawson Lakes Campus, Adelaide, SA 5095 (Australia); Wong, Ming H. [Croucher Institute for Environmental Sciences, Department of Biology, Hong Kong Baptist University, Kowloon Tong (China)

    2013-05-15

    Highlights: ► Human toxicity of hazardous substances in e-waste. ► Environmental impacts of e-waste from disposal processes. ► Life Cycle Assessment (LCA), Material Flow Analysis (MFA), Multi Criteria Analysis (MCA) and Extended Producer Responsibility (EPR) to and solve e-waste problems. ► Key issues relating to tools managing e-waste for sustainable e-waste management. - Abstract: Electronic waste (e-waste) is one of the fastest-growing pollution problems worldwide given the presence if a variety of toxic substances which can contaminate the environment and threaten human health, if disposal protocols are not meticulously managed. This paper presents an overview of toxic substances present in e-waste, their potential environmental and human health impacts together with management strategies currently being used in certain countries. Several tools including Life Cycle Assessment (LCA), Material Flow Analysis (MFA), Multi Criteria Analysis (MCA) and Extended Producer Responsibility (EPR) have been developed to manage e-wastes especially in developed countries. The key to success in terms of e-waste management is to develop eco-design devices, properly collect e-waste, recover and recycle material by safe methods, dispose of e-waste by suitable techniques, forbid the transfer of used electronic devices to developing countries, and raise awareness of the impact of e-waste. No single tool is adequate but together they can complement each other to solve this issue. A national scheme such as EPR is a good policy in solving the growing e-waste problems.

  1. Electronic waste management approaches: An overview

    International Nuclear Information System (INIS)

    Kiddee, Peeranart; Naidu, Ravi; Wong, Ming H.

    2013-01-01

    Highlights: ► Human toxicity of hazardous substances in e-waste. ► Environmental impacts of e-waste from disposal processes. ► Life Cycle Assessment (LCA), Material Flow Analysis (MFA), Multi Criteria Analysis (MCA) and Extended Producer Responsibility (EPR) to and solve e-waste problems. ► Key issues relating to tools managing e-waste for sustainable e-waste management. - Abstract: Electronic waste (e-waste) is one of the fastest-growing pollution problems worldwide given the presence if a variety of toxic substances which can contaminate the environment and threaten human health, if disposal protocols are not meticulously managed. This paper presents an overview of toxic substances present in e-waste, their potential environmental and human health impacts together with management strategies currently being used in certain countries. Several tools including Life Cycle Assessment (LCA), Material Flow Analysis (MFA), Multi Criteria Analysis (MCA) and Extended Producer Responsibility (EPR) have been developed to manage e-wastes especially in developed countries. The key to success in terms of e-waste management is to develop eco-design devices, properly collect e-waste, recover and recycle material by safe methods, dispose of e-waste by suitable techniques, forbid the transfer of used electronic devices to developing countries, and raise awareness of the impact of e-waste. No single tool is adequate but together they can complement each other to solve this issue. A national scheme such as EPR is a good policy in solving the growing e-waste problems

  2. Manual on shielded enclosures. Incorporating: Applications guide, procedures guide, basics guide

    International Nuclear Information System (INIS)

    1996-01-01

    This publication is part of practical radiation safety manual series for different fields of application aimed primarily at persons handling radiation sources on a daily routine basis, which could at same time be used by the competent authorities, supporting their efforts in the radiation protection training of workers or medical assistance personnel or helping on-site management to set up local radiation protection rules. It is dedicated to shielding enclosures: their application and procedures guides

  3. Predicting Multiple Functions of Sustainable Flood Retention Basins under Uncertainty via Multi-Instance Multi-Label Learning

    Directory of Open Access Journals (Sweden)

    Qinli Yang

    2015-03-01

    Full Text Available The ambiguity of diverse functions of sustainable flood retention basins (SFRBs may lead to conflict and risk in water resources planning and management. How can someone provide an intuitive yet efficient strategy to uncover and distinguish the multiple potential functions of SFRBs under uncertainty? In this study, by exploiting both input and output uncertainties of SFRBs, the authors developed a new data-driven framework to automatically predict the multiple functions of SFRBs by using multi-instance multi-label (MIML learning. A total of 372 sustainable flood retention basins, characterized by 40 variables associated with confidence levels, were surveyed in Scotland, UK. A Gaussian model with Monte Carlo sampling was used to capture the variability of variables (i.e., input uncertainty, and the MIML-support vector machine (SVM algorithm was subsequently applied to predict the potential functions of SFRBs that have not yet been assessed, allowing for one basin belonging to different types (i.e., output uncertainty. Experiments demonstrated that the proposed approach enables effective automatic prediction of the potential functions of SFRBs (e.g., accuracy >93%. The findings suggest that the functional uncertainty of SFRBs under investigation can be better assessed in a more comprehensive and cost-effective way, and the proposed data-driven approach provides a promising method of doing so for water resources management.

  4. A new kind of data acquisition control system with multi-functions

    International Nuclear Information System (INIS)

    Zhang Songshou; Li Shuyuan; Li Runxin; Guo Dunjun

    1996-01-01

    The paper introduces a new kind of data acquisition control system with multi-functions. The system uses the single-chip microcomputer and the standard STD system. The text recounts its functions, principal, constitution, software and hardware designs, experiment outcome and the conclusions

  5. The effect of deltamethrin-treated net fencing around cattle enclosures on outdoor-biting mosquitoes in Kumasi, Ghana.

    Directory of Open Access Journals (Sweden)

    Marta Ferreira Maia

    Full Text Available Classic vector control strategies target mosquitoes indoors as the main transmitters of malaria are indoor-biting and -resting mosquitoes. However, the intensive use of insecticide-treated bed-nets (ITNs and indoor residual spraying have put selective pressure on mosquitoes to adapt in order to obtain human blood meals. Thus, early-evening and outdoor vector activity is becoming an increasing concern. This study assessed the effect of a deltamethrin-treated net (100 mg/m(2 attached to a one-meter high fence around outdoor cattle enclosures on the number of mosquitoes landing on humans. Mosquitoes were collected from four cattle enclosures: Pen A - with cattle and no net; B - with cattle and protected by an untreated net; C - with cattle and protected by a deltamethrin-treated net; D - no cattle and no net. A total of 3217 culicines and 1017 anophelines were collected, of which 388 were Anopheles gambiae and 629 An. ziemanni. In the absence of cattle nearly 3 times more An. gambiae (p<0.0001 landed on humans. The deltamethrin-treated net significantly reduced (nearly three-fold, p<0.0001 culicine landings inside enclosures. The sporozoite rate of the zoophilic An. ziemanni, known to be a secondary malaria vector, was as high as that of the most competent vector An. gambiae; raising the potential of zoophilic species as secondary malaria vectors. After deployment of the ITNs a deltamethrin persistence of 9 months was observed despite exposure to African weather conditions. The outdoor use of ITNs resulted in a significant reduction of host-seeking culicines inside enclosures. Further studies investigating the effectiveness and spatial repellence of ITNs around other outdoor sites, such as bars and cooking areas, as well as their direct effect on vector-borne disease transmission are needed to evaluate its potential as an appropriate outdoor vector control tool for rural Africa.

  6. A Multi-Approach Evaluation System (MA-ES) of Organic Rankine Cycles (ORC) used in waste heat utilization

    International Nuclear Information System (INIS)

    Shu, Gequn; Yu, Guopeng; Tian, Hua; Wei, Haiqiao; Liang, Xingyu

    2014-01-01

    Highlights: • The MA-ES provides comprehensive valuations on ORC used for waste heat utilization. • The MA-ES covers energetic, exergetic and economic evaluations of typical ORCs. • The MA-ES is a general assessing method without restriction to specific ORC condition. • Two ORC cases of ICE waste-heat-recovery are exemplified applying the MA-ES. - Abstract: A Multi-Approach Evaluation System (MA-ES) is established in this paper providing comprehensive evaluations on Organic Rankine Cycles (ORC) used for waste heat utilization. The MA-ES covers three main aspects of typical ORC performance: basic evaluations of energy distribution and system efficiency based on the 1st law of thermodynamics; evaluations of exergy distribution and exergy efficiency based on the 2nd law of thermodynamics; economic evaluations based on calculations of equipment capacity, investment and cost recovery. The MA-ES is reasonably organized aiming at providing a general method of ORC performance assessment, without restrictions to system configurations, operation modes, applications, working fluid types, equipment conditions, process parameters and so on. Two ORC cases of internal combustion engines’ (ICEs) waste-heat-recovery are exemplified to illustrate the applications of the evaluation system. The results clearly revealed the performance comparisons among ORC configurations and working fluids referred. The comparisons will provide credible guidance for ORC design, equipment selection and system construction

  7. Reusable frame greenhouse that saves money and erection time and reduces waste generation

    International Nuclear Information System (INIS)

    Greenhalgh, W.O.; Ott, D.T.

    1977-01-01

    An improved greenhouse design has been proposed and tested for use at the Hanford Engineering Development Laboratory for containing radioactive materials during decontamination, maintenance, and remodeling operations in nuclear facilities. The advantages of the greenhouse design include a reusable frame that is free standing and self-supporting and a plastic enclosure that is easily erected and attached to the frame. Manpower requirements appear to be about half that of the conventional greenhouse, the construction costs are approximately 20 to 40% lower, and the waste generated from the greenhouse is approximately 60% lower

  8. Central waste complex interim safety basis

    International Nuclear Information System (INIS)

    Cain, F.G.

    1995-01-01

    This interim safety basis provides the necessary information to conclude that hazards at the Central Waste Complex are controlled and that current and planned activities at the CWC can be conducted safely. CWC is a multi-facility complex within the Solid Waste Management Complex that receives and stores most of the solid wastes generated and received at the Hanford Site. The solid wastes that will be handled at CWC include both currently stored and newly generated low-level waste, low-level mixed waste, contact-handled transuranic, and contact-handled TRU mixed waste

  9. 9 CFR 3.14 - Primary enclosures used to transport live dogs and cats.

    Science.gov (United States)

    2010-01-01

    ... live dogs and cats. 3.14 Section 3.14 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION..., Treatment, and Transportation of Dogs and Cats 1 Transportation Standards § 3.14 Primary enclosures used to transport live dogs and cats. Any person subject to the Animal Welfare regulations (9 CFR parts 1, 2, and 3...

  10. Investigations into the dynamics of aerosols in enclosures as used for air pollution studies

    NARCIS (Netherlands)

    Vate, van de J.F.

    1980-01-01

    This thesis treats aerosol behaviour under various conditions in enclosed spaces. Knowledge of this behaviour is of importance for the use of aerosol-filled enclosures as a supply of aerosol, as a means for aerosol characterization and for so-called smog chambers for air pollution research (mainly

  11. Melt processed crystalline ceramic waste forms for advanced nuclear fuel cycles: CRP T21027 1813: Processing technologies for high level waste, formulation of matrices and characterization of waste forms, Task 17208: Final report

    Energy Technology Data Exchange (ETDEWEB)

    Amoroso, J. W. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Marra, J. C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-08-26

    A multi-phase ceramic waste form is being developed at the Savannah River National Laboratory (SRNL) for treatment of secondary waste streams generated by reprocessing commercial spent nuclear. The envisioned waste stream contains a mixture of transition, alkali, alkaline earth, and lanthanide metals. Ceramic waste forms are tailored (engineered) to incorporate waste components as part of their crystal structure based on knowledge from naturally found minerals containing radioactive and non-radioactive species similar to the radionuclides of concern in wastes from fuel reprocessing. The ability to tailor ceramics to mimic naturally occurring crystals substantiates the long term stability of such crystals (ceramics) over geologic timescales of interest for nuclear waste immobilization [1]. A durable multi-phase ceramic waste form tailored to incorporate all the waste components has the potential to broaden the available disposal options and thus minimize the storage and disposal costs associated with aqueous reprocessing. This report summarizes results from three years of work on the IAEA Coordinated Research Project on “Processing technologies for high level waste, formulation of matrices and characterization of waste forms” (T21027), and specific task “Melt Processed Crystalline Ceramic Waste Forms for Advanced Nuclear Fuel Cycles” (17208).

  12. Melt processed crystalline ceramic waste forms for advanced nuclear fuel cycles: CRP T21027 1813: Processing technologies for high level waste, formulation of matrices and characterization of waste forms, task 17208: Final report

    Energy Technology Data Exchange (ETDEWEB)

    Amoroso, J. W. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Marra, J. C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-08-26

    A multi-phase ceramic waste form is being developed at the Savannah River National Laboratory (SRNL) for treatment of secondary waste streams generated by reprocessing commercial spent nuclear. The envisioned waste stream contains a mixture of transition, alkali, alkaline earth, and lanthanide metals. Ceramic waste forms are tailored (engineered) to incorporate waste components as part of their crystal structure based on knowledge from naturally found minerals containing radioactive and non-radioactive species similar to the radionuclides of concern in wastes from fuel reprocessing. The ability to tailor ceramics to mimic naturally occurring crystals substantiates the long term stability of such crystals (ceramics) over geologic timescales of interest for nuclear waste immobilization [1]. A durable multi-phase ceramic waste form tailored to incorporate all the waste components has the potential to broaden the available disposal options and thus minimize the storage and disposal costs associated with aqueous reprocessing. This report summarizes results from three years of work on the IAEA Coordinated Research Project on “Processing technologies for high level waste, formulation of matrices and characterization of waste forms” (T21027), and specific task “Melt Processed Crystalline Ceramic Waste Forms for Advanced Nuclear Fuel Cycles” (17208).

  13. Entropy Generation Analysis of Natural Convection in Square Enclosures with Two Isoflux Heat Sources

    Directory of Open Access Journals (Sweden)

    S. Z. Nejad

    2017-04-01

    Full Text Available This study investigates entropy generation resulting from natural convective heat transfer in square enclosures with local heating of the bottom and symmetrical cooling of the sidewalls. This analysis tends to optimize heat transfer of two pieces of semiconductor in a square electronic package. In this simulation, heaters are modeled as isoflux heat sources and sidewalls of the enclosure are isothermal heat sinks. The top wall and the non-heated portions of the bottom wall are adiabatic. Flow and temperature fields are obtained by numerical simulation of conservation equations of mass, momentum and energy in laminar, steady and two dimensional flows. With constant heat energy into the cavity, effect of Rayleigh number, heater length, heater strength ratios and heater position is evaluated on flow and temperature fields and local entropy generation. The results show that a minimum entropy generation rate is obtained under the same condition in which a minimum peak heater temperature is obtained.

  14. Ventilation of radioactive enclosures; Ventilation des enceintes radioactives

    Energy Technology Data Exchange (ETDEWEB)

    Caminade, F; Laurent, H [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    Mechanical, physical and chemical manipulations on radioactive products must be carried out in properly ventilated enclosed places. The air extracted can only be discharged into the atmosphere after a correct filtration. The power of the ventilation systems is a function of the dimensions and purpose of the enclosure? The choice of types of filter is determined by the physical state and chemical nature of the radioactive materials to be manipulated. This study deals with the individual equipment of small installations: glove boxes, manipulation boxes with outside control and, if necessary, production chambers (maximum useful volume: 5 m{sup 3}). The performances of three types of 'ventilators', and the modifications provided by the addition of filters, are measured and compared. (author) [French] Les manipulations oceaniques, physiques et chimiques sur des produits radioactifs doivent s'effectuer dans des enceintes convenablement ventilees. L'air extrait ne peut etre rejete dans l'atmosphere qu'apres une filtration correcte. La puissance des installations de ventilation est fonction des dimensions de l'enceinte et de son utilisation. Le choix des types de filtres est determine par l'etat physique et la nature ehimique des corps radioactifs manipules. Notre etude porte sur l'equipement individuel d'installations de petites dimensions: boites a gants, boites a pinces et, a la rigueur, enceintes de production (volume maximum utilisable 5 m{sup 3}). Nous mesurons et comparons les performances de trois types de 'ventilateurs' et les modifications apportees par l'adjonction de filtres. (auteur)

  15. Improving Multi-Functional Properties in Polymer Based Nano Composites by Interfacial

    Science.gov (United States)

    Tajaddod, Navid

    Polymer nanocomposites (PNCs) have become an area of increasing interest for study in the field of polymer science and technology since the rise of nanotechnology research. Despite the significant amount of progress being made towards producing high quality PNC materials, improvement in the mechanical, electrical, thermal and other functional properties still remain a challenge. To date, these properties are only a fraction of the expected theoretical values predicted for these materials. Development of interfacial regions between the filler and matrix within the composite has been found to be an important focus in terms of processing. Proper interfacial control and development may ensure excellent interaction and property transfer between the filler and polymer matrix in addition to improvement of multi-functional properties of PNCs. The property-structure importance for the existence of the interfacial and interphase region within PNCs is discussed in this thesis work. Two specific PNC systems are selected for study as part of this dissertation in order to understand the effect of interfacial region development on influencing multi-functional property trends. Polyethylene (PE)/boron nitride (BN) and polyacrylonitrile (PAN)/carbon nanotube (CNT) composites were selected to investigate their mechanical performance and thermal and electrical conductivity properties, respectively. For these systems it was found that the interfacial region structure is directly related to the enhancement of the subsequent multi-functional properties.

  16. 9 CFR 3.36 - Primary enclosures used to transport live guinea pigs and hamsters.

    Science.gov (United States)

    2010-01-01

    ... live guinea pigs and hamsters. 3.36 Section 3.36 Animals and Animal Products ANIMAL AND PLANT HEALTH..., Care, Treatment, and Transportation of Guinea Pigs and Hamsters Transportation Standards § 3.36 Primary enclosures used to transport live guinea pigs and hamsters. No person subject to the Animal Welfare...

  17. An Educational Laboratory Experiment to Demonstrate the Development of Fires in a Long Enclosure

    Science.gov (United States)

    Moinuddin, Khalid

    2013-01-01

    This paper is aimed at describing an experiment involving flame-front movement across the fuel package located within long enclosures and associated heat transfer mechanism. There is a growing interest in incorporating safety education in the chemical engineering curriculum, especially in relation to "facility siting." This experiment is…

  18. Why are our children wasting: Determinants of wasting among under 5s in Ghana.

    Science.gov (United States)

    Darteh, Eugene Kofuor Maafo; Acquah, Evelyn; Darteh, Florie

    2017-09-01

    Wasting is one of the indicators of malnutrition known to contribute to the deaths occurring from childhood malnutrition. It is the measure of body mass in relation to body length used to explain recent nutritional status. This paper examines the determinants of wasting among under 5s in Ghana. Data were drawn from the 2014 Ghana Demographic and Health Survey children's records file to examine the determinants of wasting among children. A total of 2720 children under 5 years with valid anthropometric data were used. Data on wasting were collected by measuring the weight and height of all children under 5 years of age. Bi-variate and multi-variate statistics are used to examine the determinants of wasting. The bi-variate analysis showed significant differences ( p 5s according to age of the child, region, and wealth status. On the other hand, the multi-variate analysis revealed that the odds of wasting were lower among children aged 24-35 months (Odds ratio (OR) = 0.37; p 5s. Also, efforts should be made by the relevant government agencies and other stakeholders to strengthen the socio-economic status of mothers to enable them to provide adequate nutrition and improve access to health insurance for their children in order to reduce the incidence of wasting among these children.

  19. Measure Guideline. Deep Energy Enclosure Retrofit for Interior Insulation of Masonry Walls

    Energy Technology Data Exchange (ETDEWEB)

    Musunuru, S. [Building Science Corporation, Westford, MA (United States); Pettit, B. [Building Science Corporation, Westford, MA (United States)

    2015-04-30

    This Measure Guideline describes a deep energy enclosure retrofit solution for insulating mass masonry buildings from the interior. It describes the retrofit assembly, technical details, and installation sequence for retrofitting masonry walls. Interior insulation of masonry retrofits might adversely affect the durability of the wall. This guideline includes a review of decision criteria pertinent to retrofitting masonry walls from the interior and the possible risk of freeze-thaw damage.

  20. Integrated waste management - Looking beyond the solid waste horizon

    International Nuclear Information System (INIS)

    Seadon, J.K.

    2006-01-01

    Waste as a management issue has been evident for over four millennia. Disposal of waste to the biosphere has given way to thinking about, and trying to implement, an integrated waste management approach. In 1996 the United Nations Environmental Programme (UNEP) defined 'integrated waste management' as 'a framework of reference for designing and implementing new waste management systems and for analysing and optimising existing systems'. In this paper the concept of integrated waste management as defined by UNEP is considered, along with the parameters that constitute integrated waste management. The examples used are put into four categories: (1) integration within a single medium (solid, aqueous or atmospheric wastes) by considering alternative waste management options (2) multi-media integration (solid, aqueous, atmospheric and energy wastes) by considering waste management options that can be applied to more than one medium (3) tools (regulatory, economic, voluntary and informational) and (4) agents (governmental bodies (local and national), businesses and the community). This evaluation allows guidelines for enhancing success: (1) as experience increases, it is possible to deal with a greater complexity; and (2) integrated waste management requires a holistic approach, which encompasses a life cycle understanding of products and services. This in turn requires different specialisms to be involved in the instigation and analysis of an integrated waste management system. Taken together these advance the path to sustainability

  1. Improving Video Generation for Multi-functional Applications

    OpenAIRE

    Kratzwald, Bernhard; Huang, Zhiwu; Paudel, Danda Pani; Dinesh, Acharya; Van Gool, Luc

    2017-01-01

    In this paper, we aim to improve the state-of-the-art video generative adversarial networks (GANs) with a view towards multi-functional applications. Our improved video GAN model does not separate foreground from background nor dynamic from static patterns, but learns to generate the entire video clip conjointly. Our model can thus be trained to generate - and learn from - a broad set of videos with no restriction. This is achieved by designing a robust one-stream video generation architectur...

  2. Measurement of multi-bunch transfer functions using time-domain data and Fourier analysis

    International Nuclear Information System (INIS)

    Hindi, H.; Sapozhnikov, L.; Fox, J.; Prabhakar, S.; Oxoby, G.; Linscott, I.; Drago, A.

    1993-12-01

    Multi-bunch transfer functions are principal ingredients in understanding both the behavior of high-current storage rings as well as control of their instabilities. The measurement of transfer functions on a bunch-by-bunch basis is particularly important in the design of active feedback systems. Traditional methods of network analysis that work well in the single bunch case become difficult to implement for many bunches. We have developed a method for obtaining empirical estimates of the multi-bunch longitudinal transfer functions from the time-domain measurements of the bunches' phase oscillations. This method involves recording the response of the bunch of interest to a white-noise excitation. The transfer function can then be computed as the ratio of the fast Fourier transforms (FFTs) of the response and excitation sequences, averaged over several excitations. The calculation is performed off-line on bunch-phase data and is well-suited to the multi-bunch case. A description of this method and an analysis of its performance is presented with results obtained using the longitudinal quick prototype feedback system developed at SLAC

  3. Accuracy Improvement of Boron Meter Adopting New Fitting Function and Multi-Detector

    Directory of Open Access Journals (Sweden)

    Chidong Kong

    2016-12-01

    Full Text Available This paper introduces a boron meter with improved accuracy compared with other commercially available boron meters. Its design includes a new fitting function and a multi-detector. In pressurized water reactors (PWRs in Korea, many boron meters have been used to continuously monitor boron concentration in reactor coolant. However, it is difficult to use the boron meters in practice because the measurement uncertainty is high. For this reason, there has been a strong demand for improvement in their accuracy. In this work, a boron meter evaluation model was developed, and two approaches were considered to improve the boron meter accuracy: the first approach uses a new fitting function and the second approach uses a multi-detector. With the new fitting function, the boron concentration error was decreased from 3.30 ppm to 0.73 ppm. With the multi-detector, the count signals were contaminated with noise such as field measurement data, and analyses were repeated 1,000 times to obtain average and standard deviations of the boron concentration errors. Finally, using the new fitting formulation and multi-detector together, the average error was decreased from 5.95 ppm to 1.83 ppm and its standard deviation was decreased from 0.64 ppm to 0.26 ppm. This result represents a great improvement of the boron meter accuracy.

  4. Accuracy improvement of boron meter adopting new fitting function and multi-detector

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Chidong; Lee, Hyun Suk; Tak, Tae Woo; Lee, Deok Jung [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of); KIm, Si Hwan; Lyou, Seok Jean [Users Incorporated Company, Hansin S-MECA, Daejeon (Korea, Republic of)

    2016-12-15

    This paper introduces a boron meter with improved accuracy compared with other commercially available boron meters. Its design includes a new fitting function and a multi-detector. In pressurized water reactors (PWRs) in Korea, many boron meters have been used to continuously monitor boron concentration in reactor coolant. However, it is difficult to use the boron meters in practice because the measurement uncertainty is high. For this reason, there has been a strong demand for improvement in their accuracy. In this work, a boron meter evaluation model was developed, and two approaches were considered to improve the boron meter accuracy: the first approach uses a new fitting function and the second approach uses a multi-detector. With the new fitting function, the boron concentration error was decreased from 3.30 ppm to 0.73 ppm. With the multi-detector, the count signals were contaminated with noise such as field measurement data, and analyses were repeated 1,000 times to obtain average and standard deviations of the boron concentration errors. Finally, using the new fitting formulation and multi-detector together, the average error was decreased from 5.95 ppm to 1.83 ppm and its standard deviation was decreased from 0.64 ppm to 0.26 ppm. This result represents a great improvement of the boron meter accuracy.

  5. Unify a hazardous materials/waste program

    International Nuclear Information System (INIS)

    Carson, H.T.

    1988-01-01

    Efficiently managing a hazardous materials/waste program in a multi-facility, multi-product corporation is a major challenge. This paper describes several methods to help unify a program and gain maximum efficiency of manpower and to minimize risk

  6. The Multi-Functional Implement: A tool to jump-start development

    OpenAIRE

    Moore, Keith M.

    2013-01-01

    Metadata only record This article describes the advantages of the Multi-Functional Implement, a tool that can be used for a variety of farm tasks in the context of conservation agriculture. CCRA-8 (Technology Networks for Sustainable Innovation)

  7. Multi-heme Cytochromes in Shewanella oneidensis MR-1: Structures, functions and opportunities

    Energy Technology Data Exchange (ETDEWEB)

    Breuer, Marian; Rosso, Kevin M.; Blumberger, Jochen; Butt, Julea N.

    2014-11-05

    Multi-heme cytochromes are employed by a range of microorganisms to transport electrons over distances of up to tens of nanometers. Perhaps the most spectacular utilization of these proteins is in the reduction of extracellular solid substrates, including electrodes and insoluble mineral oxides of Fe(III) and Mn(III/IV), by species of Shewanella and Geobacter. However, multi-heme cytochromes are found in numerous and phylogenetically diverse prokaryotes where they participate in electron transfer and redox catalysis that contributes to biogeochemical cycling of N, S and Fe on the global scale. These properties of multi-heme cytochromes have attracted much interest and contributed to advances in bioenergy applications and bioremediation of contaminated soils. Looking forward there are opportunities to engage multi-heme cytochromes for biological photovoltaic cells, microbial electrosynthesis and developing bespoke molecular devices. As a consequence it is timely to review our present understanding of these proteins and we do this here with a focus on the multitude of functionally diverse multi-heme cytochromes in Shewanella oneidensis MR-1. We draw on findings from experimental and computational approaches which ideally complement each other in the study of these systems: computational methods can interpret experimentally determined properties in terms of molecular structure to cast light on the relation between structure and function. We show how this synergy has contributed to our understanding of multi-heme cytochromes and can be expected to continue to do so for greater insight into natural processes and their informed exploitation in biotechnologies.

  8. Radioactive waste processing apparatus

    Science.gov (United States)

    Nelson, R.E.; Ziegler, A.A.; Serino, D.F.; Basnar, P.J.

    1985-08-30

    Apparatus for use in processing radioactive waste materials for shipment and storage in solid form in a container is disclosed. The container includes a top, and an opening in the top which is smaller than the outer circumference of the container. The apparatus includes an enclosure into which the container is placed, solution feed apparatus for adding a solution containing radioactive waste materials into the container through the container opening, and at least one rotatable blade for blending the solution with a fixing agent such as cement or the like as the solution is added into the container. The blade is constructed so that it can pass through the opening in the top of the container. The rotational axis of the blade is displaced from the center of the blade so that after the blade passes through the opening, the blade and container can be adjusted so that one edge of the blade is adjacent the cylindrical wall of the container, to insure thorough mixing. When the blade is inside the container, a substantially sealed chamber is formed to contain vapors created by the chemical action of the waste solution and fixant, and vapors emanating through the opening in the container. The chamber may be formed by placing a removable extension over the top of the container. The extension communicates with the apparatus so that such vapors are contained within the container, extension and solution feed apparatus. A portion of the chamber includes coolant which condenses the vapors. The resulting condensate is returned to the container by the force of gravity.

  9. Experimental low-frequency sound equalization in an extended region of an enclosure using adaptive filters

    DEFF Research Database (Denmark)

    Orozco-Santillán, Arturo

    1998-01-01

    An experimental investigation of sound equalization in an extended region inside an enclosure is presented. DSP and the multiple LMS algorithm is used to obtain the optimal solution. Equalization at single frequencies in the stationary state is studied. Also analyzed is the equalization of band...

  10. Energy and economic analysis of a building enclosure outfitted with a phase change material board (PCMB)

    International Nuclear Information System (INIS)

    Sun, Xiaoqin; Zhang, Quan; Medina, Mario A.; Lee, Kyoung Ok

    2014-01-01

    Highlights: • Phase change material boards (PCMBs) were simulated in building enclosures. • Energy and economic savings for these buildings were estimated. • The buildings were located in five cities with different climatic conditions. • The energy savings ratio was 100% when a cold energy source was used. • A mean electricity savings ratio of 13.1% was obtained. - Abstract: This paper presents energy and economic analyses related to the application of phase change materials boards (PCMBs) in building enclosures during the cooling season. A heat transfer model was developed, which was implemented via a computer program. Simulations were carried out using weather data files from five cities located in five different climate regions in China. Energy savings from using a natural cold source (e.g., outdoor air) and electricity savings from a reduction in electricity by air conditioning systems were evaluated. The energy savings ratio (ESR) and simple payback period (SPP) were used to assess the application of PCMBs in building enclosures. The selection of optimum phase transition temperatures for the PCMs for the various climates was made using indoor and outdoor air temperatures, as well as SPP. For space cooling purposes, it was suggested that phase transition temperatures should be at least 3 °C higher than the mean outdoor air temperature. Simple payback period suggested the possibility of the cost effective use of PCMBs in occupied buildings for moderate temperature climates

  11. A multi-functional guanine derivative for studying the DNA G-quadruplex structure.

    Science.gov (United States)

    Ishizuka, Takumi; Zhao, Pei-Yan; Bao, Hong-Liang; Xu, Yan

    2017-10-23

    In the present study, we developed a multi-functional guanine derivative, 8F G, as a G-quadruplex stabilizer, a fluorescent probe for the detection of G-quadruplex formation, and a 19 F sensor for the observation of the G-quadruplex. We demonstrate that the functional nucleoside bearing a 3,5-bis(trifluoromethyl)benzene group at the 8-position of guanine stabilizes the DNA G-quadruplex structure and fluoresces following the G-quadruplex formation. Furthermore, we show that the functional sensor can be used to directly observe DNA G-quadruplexes by 19 F-NMR in living cells. To our knowledge, this is the first study showing that the nucleoside derivative simultaneously allows for three kinds of functions at a single G-quadruplex DNA. Our results suggest that the multi-functional nucleoside derivative can be broadly used for studying the G-quadruplex structure and serves as a powerful tool for examining the molecular basis of G-quadruplex formation in vitro and in living cells.

  12. An integrated experimental and computational approach to material selection for sound proof thermally insulted enclosure of a power generation system

    Science.gov (United States)

    Waheed, R.; Tarar, W.; Saeed, H. A.

    2016-08-01

    Sound proof canopies for diesel power generators are fabricated with a layer of sound absorbing material applied to all the inner walls. The physical properties of the majority of commercially available sound proofing materials reveal that a material with high sound absorption coefficient has very low thermal conductivity. Consequently a good sound absorbing material is also a good heat insulator. In this research it has been found through various experiments that ordinary sound proofing materials tend to rise the inside temperature of sound proof enclosure in certain turbo engines by capturing the heat produced by engine and not allowing it to be transferred to atmosphere. The same phenomenon is studied by creating a finite element model of the sound proof enclosure and performing a steady state and transient thermal analysis. The prospects of using aluminium foam as sound proofing material has been studied and it is found that inside temperature of sound proof enclosure can be cut down to safe working temperature of power generator engine without compromise on sound proofing.

  13. EVALUATION OF BIOMEDICAL WASTE MANAGEMENT PRACTICES IN MULTI-SPECIALITY TERTIARY HOSPITAL

    Directory of Open Access Journals (Sweden)

    Shalini Srivastav

    2010-06-01

    Full Text Available Background: Biomedical Waste (BMW, collection and proper disposal has become a significant concern for both the medical and the general community The scientific “Hospital waste Management “is of vital importance as its improper management poses risks to the health care workers ,waste handlers patients, community in general and largely the environment. Objectives: (i To assess current practices of Bio-medical Waste management including generation, collection, transportation storage, treatment and disposal technologies in tertiary health care center. (ii To assess health andsafetypracticesfor the health care personnel involved in Bio-Medical waste Management. Materials and Methods: Waste management practices in tertiary care-centre was studied during May 2010 June 2010. The information/data regarding Bio-Medical Waste Management practices and safety was collected by way of semi structured interview, proforma being the one used for WASTE AUDITING QUESTIONNAIRE. The information collected was verified by personal observations of waste management practices in each ward of hospital. Results : SRMS-IMS generates 1. 25Kgs waste per bed per day and maximum waste is generated in wards. The institute has got separate color coded bins in each ward for collection of waste but segregation practices needs to be more refined. The safety measures taken by health care workers was not satisfactory it was not due to unavailability of Personal protective measures but because of un-awareness of health hazards which may occur due to improper waste management practices. Thus it is concluded that there should be strict implementation of a waste management policy set up in the institute, training and motivation must be given paramount importance to meet the current needs and standard of bio-medical waste management.

  14. Regulatory issues associated with the Multi-Purpose (MPC) system

    International Nuclear Information System (INIS)

    Roberts, J.P.; Desell, L.J.; Birch, M.L.; Morgan, R.G.

    1994-01-01

    The US Department of Energy Office of Civilian Radioactive Waste Management is developing a Multi-Purpose Canister system to promote compatibility between the waste program elements of storage, transportation, and disposal. The development of a Multi-Purpose Canister system requires meeting various regulatory requirements. These regulatory requirements are set forth in environmental and Nuclear Regulatory Commission (NRC) regulations. This paper discusses the more significant regulatory issues that must be addressed in the development of a Multi-Purpose Canister system by the Department of Energy

  15. Mixed convection from a discrete heat source in enclosures with two adjacent moving walls and filled with micropolar nanofluids

    Directory of Open Access Journals (Sweden)

    Sameh E. Ahmed

    2016-03-01

    Full Text Available This paper examines numerically the thermal and flow field characteristics of the laminar steady mixed convection flow in a square lid-driven enclosure filled with water-based micropolar nanofluids by using the finite volume method. While a uniform heat source is located on a part of the bottom of the enclosure, both the right and left sidewalls are considered adiabatic together with the remaining parts of the bottom wall. The upper wall is maintained at a relatively low temperature. Both the upper and left sidewalls move at a uniform lid-driven velocity and four different cases of the moving lid ordinations are considered. The fluid inside the enclosure is a water based micropolar nanofluid containing different types of solid spherical nanoparticles: Cu, Ag, Al2O3, and TiO2. Based on the numerical results, the effects of the dominant parameters such as Richardson number, nanofluid type, length and location of the heat source, solid volume fractions, moving lid orientations and dimensionless viscosity are examined. Comparisons with previously numerical works are performed and good agreements between the results are observed. It is found that the average Nusselt number along the heat source decreases as the heat source length increases while it increases when the solid volume fraction increases. Also, the results of the present study indicate that both the local and the average Nusselt numbers along the heat source have the highest value for the fourth case (C4. Moreover, it is observed that both the Richardson number and moving lid ordinations have a significant effect on the flow and thermal fields in the enclosure.

  16. Poly(ethylene-co-butylene) functionalized multi walled carbon nanotubes applied in polypropylene nanocomposites

    DEFF Research Database (Denmark)

    Daugaard, Anders Egede; Jankova Atanasova, Katja; Marín, Jose Manuel Roman

    2012-01-01

    A novel functionalized multi walled carbon nanotube (MWCNT) was prepared through grafting with α-azido-poly(ethylene-co-butylene) (PEB-N3). The PEB-N3 was prepared through a two step procedure and grafted onto an industrial grade multi walled carbon nanotube (MWCNT) through a highly efficient...

  17. Specified radioactive waste final disposal act

    International Nuclear Information System (INIS)

    Yasui, Masaya

    2001-01-01

    Radioactive wastes must be finally and safely disposed far from human activities. Disposal act is a long-range task and needs to be understood and accepted by public for site selection. This paper explains basic policy of Japanese Government for final disposal act of specified radioactive wastes, examination for site selection guidelines to promote residential understanding, general concept of multi-barrier system for isolating the specific radioactive wastes, and research and technical development for radioactive waste management. (S. Ohno)

  18. Measure Guideline: Deep Energy Enclosure Retrofit for Interior Insulation of Masonry Walls

    Energy Technology Data Exchange (ETDEWEB)

    Musunuru, S. [Building Science Corporation, Westford, MA (United States); Pettit, B. [Building Science Corporation, Westford, MA (United States)

    2015-04-01

    This Measure Guideline describes a deep energy enclosure retrofit (DEER) solution for insulating mass masonry buildings from the interior. It describes the retrofit assembly, technical details, and installation sequence for retrofitting masonry walls. Interior insulation of masonry retrofits has the potential to adversely affect the durability of the wall; this document includes a review of decision criteria pertinent to retrofitting masonry walls from the interior and the possible risk of freeze-thaw damage.

  19. CORROSION MONITORING IN HANFORD NUCLEAR WASTE STORAGE TANKS, DESIGN AND DATA FROM 241-AN-102 MULTI-PROBE CORROSION MONITORING SYSTEM

    International Nuclear Information System (INIS)

    ANDA, V.S.; EDGEMON, G.L.; HAGENSEN, A.R.; BOOMER, K.D.; CAROTHERS, K.G.

    2009-01-01

    In 2008, a new Multi-Probe Corrosion Monitoring System (MPCMS) was installed in double-shell tank 241-AN-102 on the U.S. Department of Energy's Hanford Site in Washington State. Developmental design work included laboratory testing in simulated tank 241-AN-102 waste to evaluate metal performance for installation on the MPCMS as secondary metal reference electrodes. The MPCMS design includes coupon arrays as well as a wired probe which facilitates measurement of tank potential as well as corrosion rate using electrical resistance (ER) sensors. This paper presents the MPCMS design, field data obtained following installation of the MPCMS in tank 241-AN-102, and a comparison between laboratory potential data obtained using simulated waste and tank potential data obtained following field installation

  20. Hazardous waste management in pipeline terminal: a multi-pronged approach for safe disposal of tank bottom sludge

    Energy Technology Data Exchange (ETDEWEB)

    Ammanna, John [Indian Oil Corporation Limited (IOCL), Mumbai (India)

    2009-12-19

    Indian Oil Corporation Ltd., Pipeline Division owns and operates the 1850 Km long Salaya-Mathura Crude Oil Pipeline (SMPL) with installed capacity of 21 MMTPA. Almost 25 types of crude [90% imported and 10% indigenous] are received into 13 on-shore tanks at Vadinar (the Mother Station of SMPL) through 2 Nos. SPM's anchored in the Arabian Sea and located on the west coast of India in the Gulf of Kutch. Larger quantities of tank bottom sludge that gets generated in the terminal during tank M and I pose serious environmental hazards, as procedures for handling, treatment and disposal of hazardous waste are not well established. With increasingly stringent Environmental norms being enforced by Statutory / Regulatory Authorities, storage of hazardous solid waste in lagoons and its disposal through designated approved agencies within the specified time frame, becomes extremely difficult. This paper seeks to address this issue by putting forth an innovative approach to hazardous waste management in pipeline terminals having large crude oil tank farms that has been adopted at Indian Oil Corporation's Vadinar terminal of SMPL where a multi-pronged approach for safe disposal of tank bottom sludge has been successfully implemented. The terminal has since become a 'Zero sludge location'. (author)

  1. A plasma melting of noncombustible waste for vitrification

    International Nuclear Information System (INIS)

    Moon, Young Pyo; Cho, Chun Hyung; Song, Myung Jae; Han, Sang Ok

    1997-01-01

    Multi-stage experiments have been under way to develop a new technology for radioactive waste treatment to reduce volume. Korea Electric Power Research Institute(KEPRI) has been seeking various technologies in order to reduce the radioactive volume significantly and to produce very stable waste forms. Plasma melting technology which offers greater control of temperature, faster time of reaction, better control of processing, lower capital costs, greater throughput, and more efficient use of energy has caught KEPRI's attention to the noncombustible radioactive waste. For the study of plasma melting for noncombustible wastes, KEPRI leased a lab scale multi-purpose plasma furnace together with accessory facilities and performed preliminary tests. The lab scale melting experiments were carried out by using the simulated noncombustible wastes based on the field survey data from nuclear power plants. KEPRI's current study is focused to find an optimum composition ratio of various noncombustible wastes for easy melting, to investigate physical properties of molten slag, and to obtain operating parameters for continuous operations

  2. Numerical study of different conduction models for Al{sub 2}O{sub 3}-water nanofluid with variable properties inside a trapezoidal enclosure

    Energy Technology Data Exchange (ETDEWEB)

    Arani, Ali Akbar Abbasian; Azemati, Ali Akbar; Rezaee, Mohammad [University of Kashan, Kashan (Iran, Islamic Republic of); Hadavand, Behzad Shirkavand [Islamic Azad University, Abadan (Iran, Islamic Republic of)

    2017-05-15

    Natural convection in enclosures containing nanofluids is important in physical and environmental applications. Different models for conduction have been developed because of the importance of this phenomenon in natural convection in enclosures. In this study, effects of conduction models of Chon, Corcione, Khanafer, and Koo and Kleinstreuer on the natural convection inside a trapezoidal enclosure with hot and cold walls are evaluated numerically. The enclosure contains Al{sub 2}O{sub 3}-water nanofluid with variable properties. Effects of the conduction models on fluid flow, natural convection, variations in volume fraction, and diameter of nanoparticles in the models, as well as the variations in the Rayleigh number, are examined. Results show that at Rayleigh numbers of 105 and 106, the maximum and minimum values of the average Nusselt number are obtained using the models of Khanafer and Chon, respectively. In all models, the average Nusselt number presents upward and downward trends when the volume fraction of nanoparticles increases but decreases when the di- ameter of the nanoparticles increases. At Ra = 105 in all models, as the volume fraction of nanoparticles increases, the nanofluid provides a higher average Nusselt number compared with the base fluid. By contrast, at Ra = 106, at volume fractions larger than 0.01 and using the model of Chon, the average Nusselt number of the nanofluid is lower compared with that of the base fluid.

  3. Transition to chaos in a square enclosure containing internal heat sources

    Energy Technology Data Exchange (ETDEWEB)

    Baytas, A.C. [Institute For Nuclear Energy, Istanbul (Turkey)

    1995-09-01

    A numerical investigation is performed to study the transition from steady to chaotic flow of a fluid confined in a two-dimensional square cavity. The cavity has rigid walls of constant temperature containing uniformly distributed internal heat source. Effects of the Rayleigh number of flow and heat transfer rates are studied. In addition to, same problem is solved for sinusoidally changing internal heat source to show its effect on the flow model and heat transfer of the enclosures. Details of oscillatory solutions and flow bifurcations are presented.

  4. Evaluation of cardiac function using multi-shot echo planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, Tadashi; Tanitame, Nobuko; Hata, Ryoichiro; Hirai, Nobuhiko; Ikeda, Midori; Ono, Chiaki; Fukuoka, Haruhito; Ito, Katsuhide [Hiroshima Univ. (Japan). School of Medicine

    1998-01-01

    In this study, we performed multi-shot echo planar imaging (8 shot, TR/TE/FL=55 ms/18 ms/60 degrees) and k-space segmented fast gradient echo sequence (8 views per segment, TR/TE/FL=9.9 ms/1.8 ms/30 degrees) to assess cardiac function in healthy volunteers. Transaxial sections of the entire heart were obtained with both sequences in ECG triggered, breath hold, and with a 256 x 128 matrix. Resulting temporal resolution was 55 ms for echo planar imaging, and 71 ms for k-space segmented fast gradient echo sequence, respectively. Ventricular volume and ejection fraction of both ventricles and left ventricular mass obtained with multi-shot echo planar imaging were assessed in comparison with k-space segmented fast gradient echo sequence. Measurements of left ventricular volume, ejection fraction and mass obtained with multi-shot echo planar imaging demonstrated close correlation with those obtained with k-space segmented fast gradient echo sequence. Right ventricular volumes obtained with echo planar imaging were significantly higher than those obtained with k-space segmented fast gradient echo sequence. This tendency is considered to be due to differing contrast between right ventricular myocardium and fat tissue observed with echo planar imaging relative to that observed with fast gradient echo sequence, because fat suppression is always performed in echo planar images. Multi-shot echo planar imaging can be a reliable tool for measurement of cardiac functional parameters, although wall motion analysis of the left ventricle requires higher temporal resolution and a short axial section. (K.H.)

  5. Engineering materials for high level radioactive waste repository

    International Nuclear Information System (INIS)

    Wen Zhijian

    2009-01-01

    Radioactive wastes can arise from a wide range of human activities and have different physical and chemical forms with various radioactivity. The high level radioactive wastes (HLW)are characterized by nuclides of very high initial radioactivity, large thermal emissivity and the long life-term. The HLW disposal is highly concerned by the scientists and the public in the world. At present, the deep geological disposal is regarded as the most reasonable and effective way to safely dispose high-level radioactive wastes in the world. The conceptual model of HLW geological disposal in China is based on a multi-barrier system that combines an isolating geological environment with an engineering barrier system(EBS). The engineering materials in EBS include the vitrified HLW, canister, overpack, buffer materials and backfill materials. Referring to progress in the world, this paper presents the function, the requirement for material selection and design, and main scientific projects of R and D of engineering materials in HLW repository. (authors)

  6. Solving a multi-objective location routing problem for infectious waste disposal using hybrid goal programming and hybrid genetic algorithm

    Directory of Open Access Journals (Sweden)

    Narong Wichapa

    2018-01-01

    Full Text Available Infectious waste disposal remains one of the most serious problems in the medical, social and environmental domains of almost every country. Selection of new suitable locations and finding the optimal set of transport routes for a fleet of vehicles to transport infectious waste material, location routing problem for infectious waste disposal, is one of the major problems in hazardous waste management. Determining locations for infectious waste disposal is a difficult and complex process, because it requires combining both intangible and tangible factors. Additionally, it depends on several criteria and various regulations. This facility location problem for infectious waste disposal is complicated, and it cannot be addressed using any stand-alone technique. Based on a case study, 107 hospitals and 6 candidate municipalities in Upper-Northeastern Thailand, we considered criteria such as infrastructure, geology and social & environmental criteria, evaluating global priority weights using the fuzzy analytical hierarchy process (Fuzzy AHP. After that, a new multi-objective facility location problem model which hybridizes fuzzy AHP and goal programming (GP, namely the HGP model, was tested. Finally, the vehicle routing problem (VRP for a case study was formulated, and it was tested using a hybrid genetic algorithm (HGA which hybridizes the push forward insertion heuristic (PFIH, genetic algorithm (GA and three local searches including 2-opt, insertion-move and interexchange-move. The results show that both the HGP and HGA can lead to select new suitable locations and to find the optimal set of transport routes for vehicles delivering infectious waste material. The novelty of the proposed methodologies, HGP, is the simultaneous combination of relevant factors that are difficult to interpret and cost factors in order to determine new suitable locations, and HGA can be applied to determine the transport routes which provide a minimum number of vehicles

  7. Exchange factor method: an alternative zonal formulation for analysis of radiating enclosures containing participating media

    International Nuclear Information System (INIS)

    Larsen, M.E.

    1983-01-01

    The exchange factor method (EFM) is introduced and compared to the zone method (ZM). In both the EFM and ZM the region of interest is discretized into volume and surface elements, each considered to be isothermal, which are small enough to give the required resolution. A suitable set of state variables for the system is composed of the surface element radiosities and the gas element emissive powers. The EFM defines exchange factors as dimensionless total-exchange areas for radiant interchange between volume and surface elements by all possible absorption/re-emission paths, but excluding wall reflections. In the EFM, the exchange factors replace the direct-exchange areas of the ZM and are used to write energy balances for each area and volume element in the system. As in the ZM, the radiant energy balance equations result in a set of algebraic equations linear in the system state variables. The distinguishing feature of the EFM is that exchange factors may be measurable quantities. Relationships between the EFM exchange factors and the ZM direct-exchange areas are presented. EFM conservation and reciprocity laws, analogous to those of the ZM, are also included. Temperature and heat flux distributions, predicted using the EFM, for two- and three-dimensional enclosures containing absorbing/emitting, isotropically scattering, and conducting media are included. An application of the EFM is proposed which calls for the measurement of exchange factors in a scale model of the enclosure to be analyzed. The measurement of these factors in an enclosure containing an isotropically scattering medium is discussed. The effects of isotropic scattering and absorption/re-emission processes are shown to be indistinguishable in their contribution to exchange factor paths

  8. Preliminary Investigations of Some Engineering Properties for the Use of Different Soils in Waste Disposal Cover System

    International Nuclear Information System (INIS)

    Abdel Rahman, R.O.

    2008-01-01

    Near surface disposal facilities are designed to provide long term isolation for low and intermediate level radioactive wastes from the human environment by means of multi-barriers system, which consists of a combination of natural and engineering barriers that act passively to isolate the waste. Adequate and reliable multi-layer engineered cover system is required by the long-term safety concept for waste disposal to control moisture and percolation, promote surface water runoff, minimize erosion, and prevent direct exposure to the waste. In this work, investigations of some engineering properties that are utilized in hydrological and geotechnical design of capillary barrier have been estimated for different local soil textures. Measurements of the physical properties of the studied soil textures have been conducted to determine their suitability for the utilization in engineered cover system for near surface disposal facility. The soil water characteristics have been estimated from the measured physical properties using Vereeckens pedotransfer functions. The critical pressure head for different combinations of soils have been evaluated and the thickness of the finer layer has been calculated. Also some mechanical properties, angle of internal friction and the cohesion, have been estimated using pedotransfer function. The pre-compression stresses have been evaluated and the slope stability of the designed barriers has been quantified by comparing the factor of safety for each studied case for different slope values

  9. A control strategy for multi-functional converter to improve grid power quality

    DEFF Research Database (Denmark)

    Li, Fei; Wang, Xiongfei; Chen, Zhe

    2011-01-01

    The extensive use of converter-interfacing distributed energy resources (DER), combined with a large amount of nonlinear and unbalanced loads connected to the distribution power system, has led to power quality problem. This paper proposes a control strategy for a three-phase four-leg multi-funct......) for multi-functional converter is described. Simulation and hardware in the loop real time test results carried on a three-phase four-wire distributed generation system illustrate the effectiveness of the proposed control strategy.......The extensive use of converter-interfacing distributed energy resources (DER), combined with a large amount of nonlinear and unbalanced loads connected to the distribution power system, has led to power quality problem. This paper proposes a control strategy for a three-phase four-leg multi......-functional converter which can compensate reactive power, harmonic currents, unbalance, and neutral current simultaneously under distorted voltage conditions, besides the active power exchange. The capacity of the converter is taken into account. The proposed control strategy based on synchronous reference frame (SRF...

  10. First Interlaboratory Comparison on Calibration of Temperature-Controlled Enclosures in Turkey

    Science.gov (United States)

    Uytun, A.; Kalemci, M.

    2017-11-01

    The number of accredited laboratories in the field of calibration of temperature-controlled enclosures has been increasing in Turkey. One of the main criteria demonstrating the competence of a calibration laboratory is successful participation in interlaboratory comparisons. Therefore, TUBITAK UME Temperature Laboratory organized the first interlaboratory comparison on "Calibration of Temperature-Controlled Enclosures" in Turkey as a pilot laboratory between January and November, 2013. Forty accredited laboratories which provide routine calibration services to the industry in this field participated in the comparison. The standards used during the comparison was a climatic chamber for the measurements at -40 {°}C, -20 {°}C, 40 {°}C and 100 {°}C and an oven for the measurements at 200 {°}C. The protocol of the comparison was prepared considering guide EURAMET cg-20 and BS EN/IEC standards 600068-3-5 and 600068-3-11. During the comparison measurements, each participant had the liberty to choose the most convenient calibration points in terms of their accreditation scope among the values mentioned above and carried out on-site measurements at UME. The details and the results of this comparison are given in the paper. Determination of the statistical consistency of the results with the uncertainties given by the participants can be assessed by the method of En value assessment for each laboratory. En values for all measurement results based on the results of pilot and participating laboratories were calculated.

  11. Optimization of electronic enclosure design for thermal and moisture management using calibrated models of progressive complexity

    DEFF Research Database (Denmark)

    Mohanty, Sankhya; Staliulionis, Zygimantas; Shojaee Nasirabadi, Parizad

    2016-01-01

    the development of rigorous calibrated CFD models as well as simple predictive numerical tools, the current paper tackles the optimization of critical features of a typical two-chamber electronic enclosure. The progressive optimization strategy begins the design parameter selection by initially using simpler...

  12. PET image reconstruction using multi-parametric anato-functional priors

    Science.gov (United States)

    Mehranian, Abolfazl; Belzunce, Martin A.; Niccolini, Flavia; Politis, Marios; Prieto, Claudia; Turkheimer, Federico; Hammers, Alexander; Reader, Andrew J.

    2017-08-01

    In this study, we investigate the application of multi-parametric anato-functional (MR-PET) priors for the maximum a posteriori (MAP) reconstruction of brain PET data in order to address the limitations of the conventional anatomical priors in the presence of PET-MR mismatches. In addition to partial volume correction benefits, the suitability of these priors for reconstruction of low-count PET data is also introduced and demonstrated, comparing to standard maximum-likelihood (ML) reconstruction of high-count data. The conventional local Tikhonov and total variation (TV) priors and current state-of-the-art anatomical priors including the Kaipio, non-local Tikhonov prior with Bowsher and Gaussian similarity kernels are investigated and presented in a unified framework. The Gaussian kernels are calculated using both voxel- and patch-based feature vectors. To cope with PET and MR mismatches, the Bowsher and Gaussian priors are extended to multi-parametric priors. In addition, we propose a modified joint Burg entropy prior that by definition exploits all parametric information in the MAP reconstruction of PET data. The performance of the priors was extensively evaluated using 3D simulations and two clinical brain datasets of [18F]florbetaben and [18F]FDG radiotracers. For simulations, several anato-functional mismatches were intentionally introduced between the PET and MR images, and furthermore, for the FDG clinical dataset, two PET-unique active tumours were embedded in the PET data. Our simulation results showed that the joint Burg entropy prior far outperformed the conventional anatomical priors in terms of preserving PET unique lesions, while still reconstructing functional boundaries with corresponding MR boundaries. In addition, the multi-parametric extension of the Gaussian and Bowsher priors led to enhanced preservation of edge and PET unique features and also an improved bias-variance performance. In agreement with the simulation results, the clinical results

  13. Synthesis of a multi-functional DNA nanosphere barcode system for direct cell detection.

    Science.gov (United States)

    Han, Sangwoo; Lee, Jae Sung; Lee, Jong Bum

    2017-09-28

    Nucleic acid-based technologies have been applied to numerous biomedical applications. As a novel material for target detection, DNA has been used to construct a barcode system with a range of structures. This paper reports multi-functionalized DNA nanospheres (DNANSs) by rolling circle amplification (RCA) with several functionalized nucleotides. DNANSs with a barcode system were designed to exhibit fluorescence for coding enhanced signals and contain biotin for more functionalities, including targeting through the biotin-streptavidin (biotin-STA) interaction. Functionalized deoxynucleotide triphosphates (dNTPs) were mixed in the RCA process and functional moieties can be expressed on the DNANSs. The anti-epidermal growth factor receptor antibodies (anti-EGFR Abs) can be conjugated on DNANSs for targeting cancer cells specifically. As a proof of concept, the potential of the multi-functional DNANS barcode was demonstrated by direct cell detection as a simple detection method. The DNANS barcode provides a new route for the simple and rapid selective recognition of cancer cells.

  14. Productive efficiency of public and private solid waste logistics and its implications for waste management policy

    Directory of Open Access Journals (Sweden)

    Daisuke Ichinose

    2013-03-01

    Full Text Available This paper measures the productive efficiency of municipal solid waste (MSW logistics by applying data envelopment analysis (DEA to cross-sectional data of prefectures in Japan. Either through public operations or by outsourcing to private waste collection operators, prefectural governments possess the fundamental authority over waste processing operations in Japan. Therefore, we estimate a multi-input multi-output production efficiency at the prefectural level via DEA, employing several different model settings. Our data classify the MSW into household solid waste (HSW and business solid waste (BSW collected by both private and public operators as separate outputs, while the numbers of trucks and workers used by private and public operators are used as inputs. The results consistently show that geographical characteristics, such as the number of inhabited remote islands, are relatively more dominant factors for determining inefficiency. While the implication that a minimum efficient scale is not achieved in these small islands is in line with the literature suggesting that waste logistics has increasing returns at the municipal level, our results indicate that waste collection efficiency in Japan is well described by CRS technology at the prefectural level. The results also show that prefectures with higher private-sector participation, measured in terms of HSW collection, are more efficient, whereas a higher private–labor ratio negatively affects efficiency. We also provide evidence that prefectures with inefficient MSW logistics have a higher tendency of suffering from the illegal dumping of industrial waste.

  15. Scarab III Remote Vehicle Deployment for Waste Retrieval and Tank Inspection

    International Nuclear Information System (INIS)

    Burks, B.L.; Falter, D.D.; Noakes, M.; Vesco, D.

    1999-01-01

    The Robotics Technology Development Program now known as the Robotics Crosscut Program, funded the development and deployment of a small remotely operated vehicle for inspection and cleanout of small horizontal waste storage tanks that have limited access. Besides the advantage of access through tank risers as small as 18-in. diameter, the small robotic system is also significantly less expensive to procure and to operate than larger remotely operated vehicle (ROV) systems. The vehicle specified to support this activity was the ROV Technologies, Inc., Scarab. The Scarab is a tracked vehicle with an independently actuated front and rear ''toe'' degree-of-freedom which allows the stand-off and angle of the vehicle platform with respect to the floor to be changed. The Scarab is a flexible remote tool that can be used for a variety of tasks with its primary uses targeted for inspection and small scale waste retrieval. The vehicle and any necessary process equipment are mounted in a deployment and containment enclosure to simplify deployment and movement of the system from tank to tank. This paper outlines the technical issues related to the Scarab vehicle and its deployment for use in tank inspection and waste retrieval operation

  16. Directional sound beam emission from a configurable compact multi-source system

    KAUST Repository

    Zhao, Jiajun

    2018-01-12

    We propose to achieve efficient emission of highly directional sound beams from multiple monopole sources embedded in a subwavelength enclosure. Without the enclosure, the emitted sound fields have an indistinguishable or omnidirectional radiation directivity in far fields. The strong directivity formed in the presence of the enclosure is attributed to interference of sources under degenerate Mie resonances in the enclosure of anisotropic property. Our numerical simulations of sound emission from the sources demonstrate the radiation of a highly directed sound beam of unidirectional or bidirectional patterns, depending on how the sources are configured inside the enclosure. Our scheme, if achieved, can solve the challenging problem of poor directivity of a subwavelength sound system, and can guide beam forming and collimation by miniaturized devices.

  17. Measure Guideline. Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs

    Energy Technology Data Exchange (ETDEWEB)

    Loomis, H. [Building Science Corporation, Westford, MA (United States); Pettit, B. [Building Science Corporation, Westford, MA (United States)

    2015-05-29

    This Measure Guideline provides design and construction information for a deep energy enclosure retrofit solution of a flat roof assembly. It describes the strategies and procedures for an exterior retrofit of a flat wood-framed roof with brick masonry exterior walls using exterior and interior (framing cavity) insulation. The approach supported in this guide could also be adapted for use with flat wood-framed roofs with wood-framed exterior walls.

  18. Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs

    Energy Technology Data Exchange (ETDEWEB)

    Loomis, H. [Building Science Corporation, Westford, MA (United States); Pettit, B. [Building Science Corporation, Westford, MA (United States)

    2015-05-01

    This Measure Guideline provides design and construction information for a deep energy enclosure retrofit (DEER) solution of a flat roof assembly. It describes the strategies and procedures for an exterior retrofit of a flat, wood-framed roof with brick masonry exterior walls, using exterior and interior (framing cavity) insulation. The approach supported in this guide could also be adapted for use with flat, wood-framed roofs with wood-framed exterior walls.

  19. Radioactive wastes. The management of nuclear wastes. Waste workshop, first half-year - Year 2013-2014

    International Nuclear Information System (INIS)

    Esteoulle, Lucie; Rozwadowski, Elodie; Duverger, Clara

    2014-01-01

    The first part of this report first presents radioactive wastes with their definition, and their classification (radioactivity level, radioactive half-life). It addresses the issue of waste storage by presenting the different types of storage used since the 1950's (offshore storage, surface warehousing, storage in deep geological layer), and by discussing the multi-barrier approach used for storage safety. The authors then present the French strategy which is defined in the PNGMDR to develop new management modes on the long term, to improve existing management modes, and to take important events which occurred between 2010 and 2012 into account. They also briefly present the Cigeo project (industrial centre of geological storage), and evoke controversies related to the decision to locate this project in Bure (existence of geological cracks and defects, stability and tightness of the clay layer, geothermal potential of the region, economic cost). The second part proposes an overview of the issue of nuclear waste management. The author recalls the definition of a radioactive waste, indicates the origins of these wastes and their classification. She proposes a history of the radioactive waste: discovery of radioactivity, military industrialisation and awareness of the dangerousness of radioactive wastes, nuclear wastes and recent incidents (West Valley, La Hague, Windscale). An overview of policies of nuclear waste management is given: immersion of radioactive wastes, major accidental releases, solutions on the short term and on the medium term

  20. Process for remediation of plastic waste

    Science.gov (United States)

    Pol, Vilas G [Westmont, IL; Thiyagarajan, Pappannan [Germantown, MD

    2012-04-10

    A single step process for degrading plastic waste by converting the plastic waste into carbonaceous products via thermal decomposition of the plastic waste by placing the plastic waste into a reactor, heating the plastic waste under an inert or air atmosphere until the temperature of 700.degree. C. is achieved, allowing the reactor to cool down, and recovering the resulting decomposition products therefrom. The decomposition products that this process yields are carbonaceous materials, and more specifically egg-shaped and spherical-shaped solid carbons. Additionally, in the presence of a transition metal compound, this thermal decomposition process produces multi-walled carbon nanotubes.

  1. Multi-channel distributed coordinated function over single radio in wireless sensor networks.

    Science.gov (United States)

    Campbell, Carlene E-A; Loo, Kok-Keong Jonathan; Gemikonakli, Orhan; Khan, Shafiullah; Singh, Dhananjay

    2011-01-01

    Multi-channel assignments are becoming the solution of choice to improve performance in single radio for wireless networks. Multi-channel allows wireless networks to assign different channels to different nodes in real-time transmission. In this paper, we propose a new approach, Multi-channel Distributed Coordinated Function (MC-DCF) which takes advantage of multi-channel assignment. The backoff algorithm of the IEEE 802.11 distributed coordination function (DCF) was modified to invoke channel switching, based on threshold criteria in order to improve the overall throughput for wireless sensor networks (WSNs) over 802.11 networks. We presented simulation experiments in order to investigate the characteristics of multi-channel communication in wireless sensor networks using an NS2 platform. Nodes only use a single radio and perform channel switching only after specified threshold is reached. Single radio can only work on one channel at any given time. All nodes initiate constant bit rate streams towards the receiving nodes. In this work, we studied the impact of non-overlapping channels in the 2.4 frequency band on: constant bit rate (CBR) streams, node density, source nodes sending data directly to sink and signal strength by varying distances between the sensor nodes and operating frequencies of the radios with different data rates. We showed that multi-channel enhancement using our proposed algorithm provides significant improvement in terms of throughput, packet delivery ratio and delay. This technique can be considered for WSNs future use in 802.11 networks especially when the IEEE 802.11n becomes popular thereby may prevent the 802.15.4 network from operating effectively in the 2.4 GHz frequency band.

  2. The effects of varied densities on the growth and emigration of adult cutthroat trout and brook trout in fenced stream enclosures

    Science.gov (United States)

    Buys, D.J.; Hilderbrand, R.H.; Kershner, J.L.

    2009-01-01

    We evaluated the effects of various density treatments on adult fish growth and emigration rates between Bonneville cutthroat trout Oncorhynchus clarki utah and brook trout Salvelinus fontinalis in stream enclosures in Beaver Creek, Idaho, We used 3 density treatments (low, ambient, and high fish densities) to evaluate density-related effects and to ensure a response. Intraspecific ambient-density tests using cutthroat trout only were also performed. Results indicated an absence of cage effects in the stream enclosures and no differences in fish growth between ambient-density stream-enclosure fish and free-range fish. Brook trout outgrew and moved less than cutthroat trout in the stream enclosures, especially as density increased, In all 3 density treatments, brook trout gained more weight than cutthroat trout, with brook trout gaining weight in each density treatment and cutthroat trout losing weight at the highest density. At high densities, cutthroat trout attempted to emigrate more frequently than brook trout in sympatry and allopatry. We observed a negative correlation between growth and emigration for interspecific cutthroat trout, indicating a possible competitive response due to the presence of brook trout. We observed similar responses for weight and emigration in trials of allopatric cutthroat trout, indicating strong intraspecific effects as density increased. While cutthroat trout showed a response to experimental manipulation with brook trout at different densities, there has been long-term coexistence between these species in Beaver Creek, This system presents a unique opportunity to study the mechanisms that lead cutthroat trout to coexist with rather than be replaced by nonnative brook trout.

  3. A multi-structural and multi-functional integrated fog collection system in cactus.

    Science.gov (United States)

    Ju, Jie; Bai, Hao; Zheng, Yongmei; Zhao, Tianyi; Fang, Ruochen; Jiang, Lei

    2012-01-01

    Multiple biological structures have demonstrated fog collection abilities, such as beetle backs with bumps and spider silks with periodic spindle-knots and joints. Many Cactaceae species live in arid environments and are extremely drought-tolerant. Here we report that one of the survival systems of the cactus Opuntia microdasys lies in its efficient fog collection system. This unique system is composed of well-distributed clusters of conical spines and trichomes on the cactus stem; each spine contains three integrated parts that have different roles in the fog collection process according to their surface structural features. The gradient of the Laplace pressure, the gradient of the surface-free energy and multi-function integration endow the cactus with an efficient fog collection system. Investigations of the structure-function relationship in this system may help us to design novel materials and devices to collect water from fog with high efficiencies.

  4. A multi-structural and multi-functional integrated fog collection system in cactus

    Science.gov (United States)

    Ju, Jie; Bai, Hao; Zheng, Yongmei; Zhao, Tianyi; Fang, Ruochen; Jiang, Lei

    2012-01-01

    Multiple biological structures have demonstrated fog collection abilities, such as beetle backs with bumps and spider silks with periodic spindle-knots and joints. Many Cactaceae species live in arid environments and are extremely drought-tolerant. Here we report that one of the survival systems of the cactus Opuntia microdasys lies in its efficient fog collection system. This unique system is composed of well-distributed clusters of conical spines and trichomes on the cactus stem; each spine contains three integrated parts that have different roles in the fog collection process according to their surface structural features. The gradient of the Laplace pressure, the gradient of the surface-free energy and multi-function integration endow the cactus with an efficient fog collection system. Investigations of the structure–function relationship in this system may help us to design novel materials and devices to collect water from fog with high efficiencies. PMID:23212376

  5. Measure Guideline: Deep Energy Enclosure Retrofit for Double-Stud Walls

    Energy Technology Data Exchange (ETDEWEB)

    Loomis, H. [Building Science Corporation, Westford, MA (United States); Pettit, B. [Building Science Corporation, Westford, MA (United States)

    2015-06-01

    This Measure Guideline describes a deep energy enclosure retrofit (DEER) solution that provides insulation to the interior of the wall assembly with the use of a double stud wall. The guide describes two approaches to retrofitting the existing the walls: one involving replacement of the existing cladding, and the other that leaves the existing cladding in place. It discusses the design principles related to the use of various insulation types, and provides strategies and procedures for implementing the double stud wall retrofit. It also evaluates important moisture-related and indoor air quality measures that need to be implemented to achieve a durable, high performance wall.

  6. Measure Guideline: Deep Energy Enclosure Retrofit for Double-Stud Walls

    Energy Technology Data Exchange (ETDEWEB)

    Loomis, H. [Building Science Corporation, Westford, MA (United States); Pettit, B. [Building Science Corporation, Westford, MA (United States)

    2015-06-22

    This Measure Guideline describes a deep energy enclosure retrofit solution that provides insulation to the interior of the wall assembly with the use of a double-stud wall. The guide describes two approaches to retrofitting the existing walls—one that involves replacing the existing cladding and the other that leaves the cladding in place. This guideline also covers the design principles related to the use of various insulation types and provides strategies and procedures for implementing the double-stud wall retrofit. It also includes an evaluation of important moisture-related and indoor air quality measures that need to be implemented to achieve a durable high-performance wall.

  7. Feasibility of waste transmutation using accelerator-driven IRIS subcritical system

    International Nuclear Information System (INIS)

    Petroviae, B.; Carelli, M.; Paramonov, D.

    2001-01-01

    Waste transmutation is considered for reducing radio-toxicity of nuclear waste generated in power reactors. Accelerator driven subcritical systems (ADS) offer certain advantages over the use of nuclear reactors. Transmutation of fission products (e.g. 99 Tc) generally requires thermal neutron spectrum, while for actinides fast spectrum provides better performance. Proposed solutions to this problem include a multi-strata approach as well as a multi-zone (thermal/fast-spectrum) single systems. In this paper we examine the feasibility of employing a dual-spectrum two-zone accelerator-driven IRIS subcritical for waste transmutation. (author)

  8. Sputtering an exterior metal coating on copper enclosure for large-scale growth of single-crystalline graphene

    DEFF Research Database (Denmark)

    Luo, Birong; Caridad, José M; Whelan, Patrick Rebsdorf

    2017-01-01

    growth. The sputtered coating suppresses nucleation density by acting as both a diffusion barrier and as a sink for excess carbon during the growth, reducing the carbon concentration in the interior of the enclosure. Field effect mobility of hBN-templated devices fabricated from graphene domains grown...

  9. Using MCDA and GIS for hazardous waste landfill siting considering land scarcity for waste disposal

    International Nuclear Information System (INIS)

    Feo, Giovanni De; Gisi, Sabino De

    2014-01-01

    Highlights: • Wasting land for the siting of hazardous waste landfills must be avoided. • The siting procedure is based on a land use map of potentially suitable areas. • All the waste facilities of the management system are simultaneously considered. • A case study is developed considering two multi-criteria techniques. • An innovative criteria weighting tool (PSW) is used in combination with the AHP. - Abstract: The main aim of this study was to develop a procedure that minimizes the wasting of space for the siting of hazardous waste landfills as part of a solid waste management system. We wanted to tackle the shortage of land for waste disposal that is a serious and growing problem in most large urban regions. The procedure combines a multi-criteria decision analysis (MCDA) approach with a geographical information system (GIS). The GIS was utilised to obtain an initial screening in order to eliminate unsuitable areas, whereas the MCDA was developed to select the most suitable sites. The novelty of the proposed siting procedure is the introduction of a new screening phase before the macro-siting step aimed at producing a “land use map of potentially suitable areas” for the siting of solid waste facilities which simultaneously takes into consideration all plant types. The issue of obtaining sites evaluations of a specific facility was coupled with the issue of not wasting land appropriate to facilitate other types of waste management options. In the developed case study, the use of an innovative criteria weighting tool (the “Priority Scale”) in combination with the Analytic Hierarchy Process was useful to easier define the priorities of the evaluation criteria in comparison with other classic methods such as the Paired Comparison Technique in combination with the Simple Additive Weighting method

  10. Using MCDA and GIS for hazardous waste landfill siting considering land scarcity for waste disposal

    Energy Technology Data Exchange (ETDEWEB)

    Feo, Giovanni De, E-mail: g.defeo@unisa.it [Department of Industrial Engineering, University of Salerno, via Giovanni Paolo II, 132, 84084 Fisciano, SA (Italy); Gisi, Sabino De [Italian National Agency for New Technologies, Energy and Sustainable Economic Development, ENEA, Water Resource Management Lab., via Martiri di Monte Sole 4, 40129 Bologna, BO (Italy)

    2014-11-15

    Highlights: • Wasting land for the siting of hazardous waste landfills must be avoided. • The siting procedure is based on a land use map of potentially suitable areas. • All the waste facilities of the management system are simultaneously considered. • A case study is developed considering two multi-criteria techniques. • An innovative criteria weighting tool (PSW) is used in combination with the AHP. - Abstract: The main aim of this study was to develop a procedure that minimizes the wasting of space for the siting of hazardous waste landfills as part of a solid waste management system. We wanted to tackle the shortage of land for waste disposal that is a serious and growing problem in most large urban regions. The procedure combines a multi-criteria decision analysis (MCDA) approach with a geographical information system (GIS). The GIS was utilised to obtain an initial screening in order to eliminate unsuitable areas, whereas the MCDA was developed to select the most suitable sites. The novelty of the proposed siting procedure is the introduction of a new screening phase before the macro-siting step aimed at producing a “land use map of potentially suitable areas” for the siting of solid waste facilities which simultaneously takes into consideration all plant types. The issue of obtaining sites evaluations of a specific facility was coupled with the issue of not wasting land appropriate to facilitate other types of waste management options. In the developed case study, the use of an innovative criteria weighting tool (the “Priority Scale”) in combination with the Analytic Hierarchy Process was useful to easier define the priorities of the evaluation criteria in comparison with other classic methods such as the Paired Comparison Technique in combination with the Simple Additive Weighting method.

  11. Multi-objective reverse logistics model for integrated computer waste management.

    Science.gov (United States)

    Ahluwalia, Poonam Khanijo; Nema, Arvind K

    2006-12-01

    This study aimed to address the issues involved in the planning and design of a computer waste management system in an integrated manner. A decision-support tool is presented for selecting an optimum configuration of computer waste management facilities (segregation, storage, treatment/processing, reuse/recycle and disposal) and allocation of waste to these facilities. The model is based on an integer linear programming method with the objectives of minimizing environmental risk as well as cost. The issue of uncertainty in the estimated waste quantities from multiple sources is addressed using the Monte Carlo simulation technique. An illustrated example of computer waste management in Delhi, India is presented to demonstrate the usefulness of the proposed model and to study tradeoffs between cost and risk. The results of the example problem show that it is possible to reduce the environmental risk significantly by a marginal increase in the available cost. The proposed model can serve as a powerful tool to address the environmental problems associated with exponentially growing quantities of computer waste which are presently being managed using rudimentary methods of reuse, recovery and disposal by various small-scale vendors.

  12. STUDY ON ALGORITHM OF SENSOR MANAGEMENT BASED ON FUNCTIONS OF EFFICIENCY AND WASTE

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Sensor management plays an important role in data fusion system, and this paper presents an algorithm of sensor management that can be used in target detection, identification and tracking. First, the basic concept, rule, range and function of sensor management are introduced. Then, the quantifying problems of target priority and sensor (or combination)-target pairing in multisensor management are discussed and the efficiency and waste functions are established based on the functions of target priority and sensor-target pairing. On this basis, a distribution algorithm of multisensor resources is given, which is optimized by the principle of maximum synthesis efficiency in the multisensor system and constrained by sensor maximum tracking power and what target must be scanned. In addition, the waste measure of sensor resources is introduced to improve the algorithm. Finally, a tactical task that includes three sensors and ten targets is set, and the simulation results show that the algorithm is feasible and effective.

  13. Multi-approach evaluations of a cascade-Organic Rankine Cycle (C-ORC) system driven by diesel engine waste heat: Part A – Thermodynamic evaluations

    International Nuclear Information System (INIS)

    Shu, Gequn; Yu, Guopeng; Tian, Hua; Wei, Haiqiao; Liang, Xingyu; Huang, Zhiyong

    2016-01-01

    Highlights: • A novel C-ORC system was proposed for recovering waste heat from a diesel engine. • Thermodynamic evaluations were conducted to explore C-ORC’s practical benefits. • C-ORC has significant heat-recovery capacities and efficiency-promotion potential. • Up to 16.0% of engine efficiency can be improved combining with C-ORC. - Abstract: A novel transcritical cascade-Organic Rankine Cycle (C-ORC) system was proposed to recover multi-grade waste heat from a typical heavy-duty diesel engine. The C-ORC comprises of a high-temperature ORC loop (HT-Loop) and a low temperature ORC loop (LT-Loop) to recover waste heat from an engine’s exhaust gas (EG), exhaust gas recirculation (EGR), jacket water (JW) and charge air (CA) in a cascaded pattern. In order to reveal the full performance of the C-ORC system, with due consideration to diesel’s complex practical running conditions, multi-approach evaluations were conducted containing two parts: Part A – thermodynamic evaluations of the energy and exergy aspects and Part B – techno-economic evaluations on costs and benefits aspects. This paper shows the Part A – evaluations of the C-ORC, focusing on indexes including recovered waste heat, net power output, thermal efficiencies and exergy efficiencies. First of all, distributions of the engine’s multi-grade waste heat were studied to reveal the characteristics and utilization potential of waste energy. The comparison and screening of working fluids were carried out next to find the best fluids for the HT-Loop and LT-Loop respectively based on the rated engine condition. Toluene, decane, cyclohexane and D4 were four proper alternatives for the HT-Loop while R143a, R125, R218 and R41 were four proper alternatives for the LT-Loop. Comparisons indicated that toluene and R143a made the perfect match for the C-ORC with the highest net power output (33.9 kW), thermal efficiency (9.9%) and exergy efficiency (39.1%). The rankings of the two groups of

  14. Effect of flow rate on environmental variables and phytoplankton dynamics: results from field enclosures

    Science.gov (United States)

    Zhang, Haiping; Chen, Ruihong; Li, Feipeng; Chen, Ling

    2015-03-01

    To investigate the effects of flow rate on phytoplankton dynamics and related environment variables, a set of enclosure experiments with different flow rates were conducted in an artificial lake. We monitored nutrients, temperature, dissolved oxygen, pH, conductivity, turbidity, chlorophyll- a and phytoplankton levels. The lower biomass in all flowing enclosures showed that flow rate significantly inhibited the growth of phytoplankton. A critical flow rate occurred near 0.06 m/s, which was the lowest relative inhibitory rate. Changes in flow conditions affected algal competition for light, resulting in a dramatic shift in phytoplankton composition, from blue-green algae in still waters to green algae in flowing conditions. These findings indicate that critical flow rate can be useful in developing methods to reduce algal bloom occurrence. However, flow rate significantly enhanced the inter-relationships among environmental variables, in particular by inducing higher water turbidity and vegetative reproduction of periphyton ( Spirogyra). These changes were accompanied by a decrease in underwater light intensity, which consequently inhibited the photosynthetic intensity of phytoplankton. These results warn that a universal critical flow rate might not exist, because the effect of flow rate on phytoplankton is interlinked with many other environmental variables.

  15. MF-CRA: Multi-Function Cognitive Radio Architecture for Space Communications, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — EpiSys Science, Inc. and University of Arizona propose to develop, implement, and demonstrate Multi-Function Cognitive Radio Architecture (MF-CRA) for Space...

  16. Performance analysis on a new multi-effect distillation combined with an open absorption heat transformer driven by waste heat

    International Nuclear Information System (INIS)

    Zhang, Xiaodong; Hu, Dapeng; Li, Zhiyi

    2014-01-01

    In this paper, a new water distillation system, which consists of either a single- or multi-effect distiller combined with an open absorption heat transformer (OAHT), has been proposed. The new integrated system can be used for distilling waste water with high amounts of SiO 2 from heavy oil production, and the resultant distilled water can be supplied to steam boilers to produce high quality steam which in turn is injected into oil reservoirs to assist with heavy oil recovery. The thermodynamic cycle performances for these new integrated distillation systems were simulated based on the thermodynamic properties of the aqueous solution of LiBr as well as the mass and energy balance of the system. The results indicate that combined with OAHT, the waste heat at 70 °C can be elevated to 125 °C and thereby produce steam at 120 °C in the absorber, which is able to drive a four-effect distiller to produce distilled water. For a single-effect and four-effect distiller, the coefficients of performance (COP) are approximately 1.02 while the performance ratios are 2.19 and 5.72, respectively. Therefore, the four-effect distillation system combined with an OAHT is more thermally effective and is an ideal option to process the waste water in oilfields. -- Highlights: • A new absorption vapor compression distillation was proposed in present research. • An open absorption heat transformer has a coupled thermally evaporator and absorber. • Distillation of waste water with high content of SiO 2 from heavy oil production. • The waste heat of 70 °C can be elevated up to 125 °C and generate steam of 120 °C. • The waste heat is able to drive four-effect distillation to produce distilled water

  17. Thermoeconomic multi-objective optimization of an organic Rankine cycle for exhaust waste heat recovery of a diesel engine

    International Nuclear Information System (INIS)

    Yang, Fubin; Zhang, Hongguang; Song, Songsong; Bei, Chen; Wang, Hongjin; Wang, Enhua

    2015-01-01

    In this paper, the ORC (Organic Rankine cycle) technology is adopted to recover the exhaust waste heat of diesel engine. The thermodynamic, economic and optimization models of the ORC system are established, respectively. Firstly, the effects of four key parameters, including evaporation pressure, superheat degree, condensation temperature and exhaust temperature at the outlet of the evaporator on the thermodynamic performances and economic indicators of the ORC system are investigated. Subsequently, based on the established optimization model, GA (genetic algorithm) is employed to solve the Pareto solution of the thermodynamic performances and economic indicators for maximizing net power output and minimizing total investment cost under diesel engine various operating conditions using R600, R600a, R601a, R245fa, R1234yf and R1234ze as working fluids. The most suitable working fluid used in the ORC system for diesel engine waste heat recovery is screened out, and then the corresponding optimal parameter regions are analyzed. The results show that thermodynamic performance of the ORC system is improved at the expense of economic performance. Among these working fluids, R245fa is considered as the most suitable working fluid for the ORC waste heat application of the diesel engine with comprehensive consideration of thermoeconomic performances, environmental impacts and safety levels. Under the various operating conditions of the diesel engine, the optimal evaporation pressure is in the range of 1.1 MPa–2.1 MPa. In addition, the optimal superheat degree and the exhaust temperature at the outlet of the evaporator are mainly influenced by the operating conditions of the diesel engine. The optimal condensation temperature keeps a nearly constant value of 298.15 K. - Highlights: • Thermoeconomic multi-objective optimization of an ORC (Organic Rankine cycle) system is conducted. • Sensitivity analysis of the decision variables is performed. • Genetic algorithm

  18. Multi-discipline Waste Acceptance Process at the Nevada National Security Site - 13573

    Energy Technology Data Exchange (ETDEWEB)

    Carilli, Jhon T. [US Department Of Energy, Nevada Site Office, P. O. Box 98518, Las Vegas, Nevada 89193-8518 (United States); Krenzien, Susan K. [Navarro-Intera, LLC, P. O. Box 98952, Las Vegas, Nevada 89193-8952 (United States)

    2013-07-01

    The Nevada National Security Site low-level radioactive waste disposal facility acceptance process requires multiple disciplines to ensure the protection of workers, the public, and the environment. These disciplines, which include waste acceptance, nuclear criticality, safety, permitting, operations, and performance assessment, combine into the overall waste acceptance process to assess low-level radioactive waste streams for disposal at the Area 5 Radioactive Waste Management Site. Four waste streams recently highlighted the integration of these disciplines: the Oak Ridge Radioisotope Thermoelectric Generators and Consolidated Edison Uranium Solidification Project material, West Valley Melter, and classified waste. (authors)

  19. Component Functional Allocations of the ESF Multi-loop Controller for the KNICS ESF-CCS Design

    International Nuclear Information System (INIS)

    Hur, Seop; Choi, Jong Kyun; Kim, Dong Hoon; Kim, Ho; Kim, Seong Tae

    2006-01-01

    The safety related components in nuclear power plants are traditionally controlled by single-loop controllers. Traditional single-loop controller systems utilize dedicated processors for each component but that components independence is compromised through a sharing of power supplies, auxiliary logic modules and auxiliary I/O cards. In the new design of the ESF-CCS, the multi-loop controllers with data networks are widely used. Since components are assigned to ESF-CCS functional groups in a manner consistent with their process relationship, the effects of the failures are predictable and manageable. Therefore, the key issues for the design of multi-loop controller is to allocate the components to the each multi-loop controller through plant and function analysis and grouping. This paper deals with an ESF component functional allocation which is performed through allocation criteria and a fault analysis

  20. Science, Society, and America's Nuclear Waste: The Waste Management System, Unit 4. Teacher Guide. Second Edition.

    Science.gov (United States)

    Department of Energy, Washington, DC. Office of Civilian Radioactive Waste Management, Washington, DC.

    This guide is Unit 4 of the four-part series, Science, Society, and America's Nuclear Waste, produced by the U.S. Department of Energy's Office Civilian Radioactive Waste Management. The goal of this unit is to explain how transportation, a geologic repository, and the multi-purpose canister will work together to provide short-term and long-term…