  1. Fire exposure of empty 30B cylinders

    Energy Technology Data Exchange (ETDEWEB)

    Ziehlke, K.T. [MJB Technical Associates, Inc., Knoxville, TN (United States)

    1991-12-31

    Cylinders for UF{sub 6} handling, transport, and storage are designed and built as unfired pressure vessels under ASME Boiler and Pressure Vessel Code criteria and standards. They are normally filled and emptied while UF{sub 6} is in its liquid phase. Transport cylinders such as the Model 30B are designed for service at 200 psi and 250{degrees}F, to sustain the process conditions which prevail during filling or emptying operations. While in transport, however, at ambient temperature the UF{sub 6} is solid, and the cylinder interior is well below atmospheric pressure. When the cylinders contain isotopically enriched product (above 1.0 percent U-235), they are transported in protective overpacks which function to guard the cylinders and their contents against thermal or mechanical damage in the event of possible transport accidents. Two bare Model 30B cylinders were accidentally exposed to a storage warehouse fire in which a considerable amount of damage was sustained by stored materials and the building structure, as well as by the cylinder valves and valve protectors. The cylinders were about six years old, and had been cleaned, inspected, hydrotested, and re-certified for service, but were still empty at the time of the fire. The privately-owned cylinders were transferred to DOE for testing and evaluation of the fire damage.

  2. Radiation levels on empty cylinders containing heel material

    Energy Technology Data Exchange (ETDEWEB)

    Shockley, C.W. [Martin Marietta Energy Systems, Inc., Paducah, KY (United States)

    1991-12-31

    Empty UF{sub 6} cylinders containing heel material were found to emit radiation levels in excess of 200 mr/hr, the maximum amount stated in ORO-651. The radiation levels were as high as 335 mr/hr for thick wall (48X and 48Y) cylinders and 1050 mr/hr for thin wall (48G and 48H) cylinders. The high readings were found only on the bottom of the cylinders. These radiation levels exceeded the maximum levels established in DOT 49 CFR, Part 173.441 for shipment of cylinders. Holding periods of four weeks for thick-wall cylinders and ten weeks for thin-wall cylinders were established to allow the radiation levels to decay prior to shipment.

  3. 46 CFR 58.30-30 - Fluid power cylinders.

    Science.gov (United States)

    2010-10-01

    ... all pneumatic power transmission systems. (b) Fluid power cylinders consisting of a container and a... 46 Shipping 2 2010-10-01 2010-10-01 false Fluid power cylinders. 58.30-30 Section 58.30-30... MACHINERY AND RELATED SYSTEMS Fluid Power and Control Systems § 58.30-30 Fluid power cylinders. (a) The...

  4. Criticality Safety Evaluation for 30B and 48X UF6 Cylinders for Transportation and Storage

    International Nuclear Information System (INIS)

    Mokhatri, Homami Zahra; Nematollahi, Mohammadreza; Kamyab, Shahabeddin

    2011-01-01

    30B and 48X cylinders are two standard containers have been used for transportation and storage of uranium hexafluoride with 21/2-ton and 10-ton loading capacity, respectively. For the sake of nuclear safety, the long-term safe storage and transportation of the cylinders are necessary to be concerned. Safe limits in handling and storage of 30B and 48X cylinders from the criticality safety considerations, has been investigated in this paper, by using the MCNP.4C code with ENDF/B-VI library data for the neutron cross sections. An infinite array model (with and without over pack) incorporating an internal H/U ratio of 0.088 was then developed to determine the optimal interstitial moderation. The maximum k eff value for the conditions of optimal interstitial moderation with the premise of no water leakage into the UF 6 cylinder has been shown to be 0.79209 ± 0.0011 for the 30B cylinder and 0.7625±0.0013 for 48X cylinder with 5 wt % 235 U enrichment. Based on this evaluation, the 30B and 48X UF 6 cylinders with 5 wt % 235 U enrichment meet the 10 CFR part 71 criteria for Fissile Class I packages, even in the worst case, and has a Transport Index (TI) of zero for criticality safety purposes

  5. Gastric emptying in patients with vitamin B12 deficiency

    International Nuclear Information System (INIS)

    Yagci, Muenci; Yamac, Kadri; Acar, Kadir; Haznedar, Rauf; Cingi, Elif; Kitapci, Mehmet

    2002-01-01

    The clinical presentation of patients with vitamin B 12 deficiency varies in a spectrum ranging from haematological disorders to neuropsychiatric diseases. In rare cases, orthostatic hypotension, impotence, constipation and urinary retention have been attributed to autonomic nervous system dysfunction due to vitamin B 12 deficiency. The aim of this study was to evaluate the effect of vitamin B 12 deficiency on autonomic nervous system function by studying gastric emptying times (T 1/2 ). Twenty patients with newly diagnosed vitamin B 12 deficiency and 12 control patients with gastritis and normal vitamin B 12 levels were enrolled in this study. Gastroduodenoscopy, endoscopic biopsy, histopathological evaluation of the biopsy specimens and radionuclide gastric emptying studies were performed. After vitamin B 12 replacement therapy for 3 months, radionuclide gastric emptying studies were repeated. Mean gastric emptying T 1/2 in patients before and after treatment and in controls were 103.83±48.80 min, 90.00±17.29 min and 74.55±8.52 min, respectively. The difference in mean gastric emptying T 1/2 between patients before treatment and controls was statistically significant (P 12 treatment (P 1/2 was somewhat shorter. There were no positive or negative correlations between gastric emptying T 1/2 and the following parameters: haemoglobin, vitamin B 12 level and Helicobacter pylori positivity. In conclusion, gastric emptying T 1/2 was prolonged in patients with vitamin B 12 deficiency and this prolongation was not corrected after vitamin B 12 replacement therapy. Although autonomic nervous system dysfunction due to vitamin B 12 deficiency rarely gives rise to clinical manifestations, latent dysfunction demonstrated by laboratory tests seems to be a frequent phenomenon. The level of vitamin B 12 does not correlate with the degree of autonomic nervous system dysfunction measured by radionuclide gastric emptying studies. (orig.)

  6. Gastric emptying in patients with vitamin B{sub 12} deficiency

    Energy Technology Data Exchange (ETDEWEB)

    Yagci, Muenci; Yamac, Kadri; Acar, Kadir; Haznedar, Rauf [Department of Hematology, Gazi Medical School (Turkey); Cingi, Elif; Kitapci, Mehmet [Department of Nuclear Medicine, Gazi Medical School (Turkey)

    2002-09-01

    The clinical presentation of patients with vitamin B{sub 12} deficiency varies in a spectrum ranging from haematological disorders to neuropsychiatric diseases. In rare cases, orthostatic hypotension, impotence, constipation and urinary retention have been attributed to autonomic nervous system dysfunction due to vitamin B{sub 12} deficiency. The aim of this study was to evaluate the effect of vitamin B{sub 12} deficiency on autonomic nervous system function by studying gastric emptying times (T{sub 1/2}). Twenty patients with newly diagnosed vitamin B{sub 12} deficiency and 12 control patients with gastritis and normal vitamin B{sub 12} levels were enrolled in this study. Gastroduodenoscopy, endoscopic biopsy, histopathological evaluation of the biopsy specimens and radionuclide gastric emptying studies were performed. After vitamin B{sub 12} replacement therapy for 3 months, radionuclide gastric emptying studies were repeated. Mean gastric emptying T{sub 1/2} in patients before and after treatment and in controls were 103.83{+-}48.80 min, 90.00{+-}17.29 min and 74.55{+-}8.52 min, respectively. The difference in mean gastric emptying T{sub 1/2} between patients before treatment and controls was statistically significant (P<0.01). The statistically significant difference persisted after vitamin B{sub 12} treatment (P<0.05), though mean gastric emptying T{sub 1/2} was somewhat shorter. There were no positive or negative correlations between gastric emptying T{sub 1/2} and the following parameters: haemoglobin, vitamin B{sub 12} level and Helicobacter pylori positivity. In conclusion, gastric emptying T{sub 1/2} was prolonged in patients with vitamin B{sub 12} deficiency and this prolongation was not corrected after vitamin B{sub 12} replacement therapy. Although autonomic nervous system dysfunction due to vitamin B{sub 12} deficiency rarely gives rise to clinical manifestations, latent dysfunction demonstrated by laboratory tests seems to be a frequent phenomenon

  7. Swap your propane cylinder with SWOP

    International Nuclear Information System (INIS)

    Anon.

    1997-01-01

    A very successful propane cylinder exchange program operated by South Western Ontario Propane (SWOP) Inc., was described. The company specializes in propane cylinder exchange and in the refurbishing and marketing of top quality domestic and commercial propane cylinders. The company, currently operating out of Bradford, Ontario, was started in 1991. It employs a staff of 25 in peak season. It has some 200 exchange outlets throughout Ontario and has accepted outdated tanks from as far west as Manitoba and as far east as Quebec. A typical transaction involves bringing an empty cylinder to the nearest SWOP location and exchanging it for a full SWOP cylinder. SWOP does about 50,000 to 60,000 exchanges a year. For the consumer, the program is said to be cheaper, safer and more convenient than getting refills. As far as dealers are concerned operating a SWOP exchange outlet can add extra profits, attract new customers, and build additional consumer loyalty without the need for extra staff or additional indoor space. SWOP delivers full cylinders to exchange outlets on a weekly basis when it also picks up the empty cylinders. At dealer locations, the cylinders (full or empty) are stored in company -designed vandal-proof metal cages. Major expansion of the network of outlets and the cylinder refurbishing and refilling facilities are planned for 1998

  8. Effects of fire exposure on integrity of UF6 shipping cylinders

    International Nuclear Information System (INIS)

    Barlow, C.R.; Ziehlke, K.T.; Pryor, W.A.

    1985-01-01

    Two 2-1/2-ton steel cylinders for the transport of uranium hexafluoride within the United States nuclear fuel enrichment cycle were involved in a warehouse fire where portions of the cylinders were estimated to have reached a temperature of 1600 0 F (870 0 C). The cylinders were empty at the time of the fire and therefore were not in protective overpacks in which full product cylinders are handled while in transit. Hydrostatic tests to failure showed that the integrity of the cylinders was not degraded by exposure to the temperatures generated by the fire. They withstood test pressures in excess of 10 times the design pressure, and showed a volume expansion of 30% above the original capacity before rupture in a completely ductile fashion. Reference CAPE-323. 9 figs

  9. Overseas shipments of 48Y cylinders

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, R.T.; Furlan, A.S. [Cameco Corp., Port Hope, Ontario (Canada)

    1991-12-31

    This paper describes experiences with two incidents of overseas shipments of uranium hexafluoride (UF{sub 6}) cylinders. The first incident involved nine empty UF{sub 6} cylinders in enclosed sea containers. Three UF{sub 6} cylinders broke free from their tie-downs and damaged and contaminated several sea containers. This paper describes briefly how decontamination was carried out. The second incident involved a shipment of 14 full UF{sub 6} cylinders. Although the incident did not cause an accident, the potential hazard was significant. The investigation of the cause of the near accident is recounted. Recommendations to alleviate future similar incidents for both cases are presented.

  10. Beneficial reuse of empty DUF{sub 6} cylinders

    Energy Technology Data Exchange (ETDEWEB)

    Nieves, L.A.; Arnish, J.; Nabelssi, B. [Argonne National Lab., IL (United States)

    1997-02-01

    This paper discusses options for the disposal of depleted UF{sub 6} storage cylinders as they are freed over the next 20 years. Presently there are 46,000 mild steel cylinders in use, and projections show 600,000 tons of steel being freed over 20 years. The paper discusses the results of studies which have looked at various aspects of this issue: health risks; environmental impacts; costs and hassles; impact of DOE metal recycle policy. The general conclusions were that chemical and trauma risks dominate the risk evaluations, that risk levels are broadly speaking level for the studied disposition options, that environmental risks are highest for burial, and lowest for free release, while costs are higher for burial and recycling, than for reuse or free release.

  11. [Diagnosis for human parvovirus B19-polyarthritis: usefulness of empty particle B19.ELISA and B19-DNA.PCR].

    Science.gov (United States)

    Hatakeyama, Y; Ishii, K; Murai, C; Sugamura, K; Mitomo, N; Saitoh, T; Rikimaru, Y; Okazaki, T; Sasaki, T

    1998-10-01

    To evaluate the usefulness of new ELISA for human parvovirus B19 (B19) antibodies and PCR for the diagnosis of acute onset of B19 polyarthritis. We evaluated the reproducibility and sensitivity on the detection of anti-B19 antibody by ELISA using recombinant VP-1 and VP-2 (empty particle), and then studied for the prevalence of IgM and IgG B19 antibody in 125 samples for anti-B19 tests. The random study on anti-B19 antibody assay as well as PCR for B19-DNA was also performed in 130 cases with acute onset of arthritis excluding those with known origins, 224 with rheumatoid arthritis and 149 with other categories. The results by using B19-empty particle ELISA were reproducible and showed the assay was a sensitive way for clinical use. IgM anti-B19 antibodies were positive not only in all samples from erythema infectiosum, but also often in those from hemolytic anemia, pure red cell aplasia, fetal hydrops, hepatic injury, fever of unknown origin. Among 130 with acute onset of arthritis, 21 showed positive tests for IgM anti-B19 antibody and/or B19 DNA. On the other hand, 4 among 224 patients with rheumatoid arthritis were positive for IgM anti-B19 antibody, but all of 149 in control group were negative for IgM anti-B19 antibodies and for B19 DNA. Anti-B19 ELISA using B19-empty particle which has been introduced as a routine test system, is a useful tool for the diagnosis of acute onset of B19 arthritis. An additional examination using PCR for B19 DNA may contribute for understanding persistent B19 polyarthritis or reactivation of B19 infection.

  12. 49 CFR 173.29 - Empty packagings.

    Science.gov (United States)

    2010-10-01

    ... hazardous material shall be offered for transportation and transported in the same manner as when it.... (c) A non-bulk packaging containing only the residue of a hazardous material covered by Table 2 of... in Column 10a of the § 172.101 table for transportation by vessel, an empty drum or cylinder may be...

  13. Cylinder monitoring program

    Energy Technology Data Exchange (ETDEWEB)

    Alderson, J.H. [Martin Marietta Energy Systems, Inc., Paducah, KY (United States)

    1991-12-31

    Cylinders containing depleted uranium hexafluoride (UF{sub 6}) in storage at the Department of Energy (DOE) gaseous diffusion plants, managed by Martin Marietta Energy Systems, Inc., are being evaluated to determine their expected storage life. Cylinders evaluated recently have been in storage service for 30 to 40 years. In the present environment, the remaining life for these storage cylinders is estimated to be 30 years or greater. The group of cylinders involved in recent tests will continue to be monitored on a periodic basis, and other storage cylinders will be observed as on a statistical sample population. The program has been extended to all types of large capacity UF{sub 6} cylinders.

  14. Field cooling of a MgB2 cylinder around a permanent magnet stack: prototype for superconductive magnetic bearing

    International Nuclear Information System (INIS)

    Perini, E; Giunchi, G

    2009-01-01

    The behaviour of bulk superconductors as levitators of permanent magnets (PMs) has been extensively studied for the textured YBCO high-temperature superconductor material, in the temperature range lower than 77 K, obtaining extremely high trapped fields but also experiencing limitations on the mechanical characteristics of the material and on the possibility to produce large objects. Alternatively, bulk MgB 2 , even if it is superconducting at lower temperatures, has fewer mechanical problems, when fully densified, and presents stable magnetization in the temperature range between 10 and 30 K. With the reactive Mg-liquid infiltration technique we have produced dense MgB 2 bulk cylinders of up to 65 mm diameter and 100 mm height. This kind of cylinder can be consider as a prototype of a passive magnetic bearing for flywheels or other rotating electrical machines. We have conductively cooled one of these superconducting cylinders inside a specially constructed cryostat, and the levitation forces and stiffness, with respect to axial movements of various arrangements of the PM, have been measured as a function of the temperature below T c . We verified the very stable characteristics of the induced magnetization after several cycles of relative movements of the PM and the superconducting cylinder.

  15. UF6 Cylinder Imaging by Fast Neutron Transmission Tomography

    International Nuclear Information System (INIS)

    McElroy, R.; Hausladen, P.; Blackston, M.; Croft, S.

    2015-01-01

    The common use Non-Destructive Assay techniques for the determination of 235 U enrichment and mass of UF6 cylinders used in the production of nuclear reactor fuel require prior knowledge of the physical distribution of the UF6 within the cylinder. The measurement performance for these techniques is typically evaluated based on assumed bounding case distributions of the material. However, little direct data such as radiographic or tomographic images, regarding the distribution of the UF6 within the cylinder is available against which to judge these assumptions. We have developed and tested a prototype active neutron tomographic imaging system employing an Associated Particle Imaging (API) neutron generator and an array of pixelated neutron scintillation counters. This system has been successfully used to obtain the 3-dimensional map of the distribution of UF6 within a type 12B storage cylinder. Results from these measurements are presented and the potential performance and utility of this technique with larger 30B and 48Y cylinders is discussed. (author)

  16. Temporary patching of damaged UF{sub 6} cylinders

    Energy Technology Data Exchange (ETDEWEB)

    Cardenas, A.L. [Martin Marietta Energy Systems, Inc., OH (United States)

    1991-12-31

    Patching techniques based on application of epoxy resins have been developed for temporarily repairing UF{sub 6} cylinders which have sustained relatively minor damage and must be safely emptied. The method is considerably faster and simpler than metallurgical weld repairs. Laboratory tests, detailed operational procedures, and case histories of experience at the Portsmouth Gaseous Diffusion Plant are described.

  17. Prediction of External Corrosion for Steel Cylinders--2007 Report

    Energy Technology Data Exchange (ETDEWEB)

    Schmoyer, Richard L [ORNL

    2008-01-01

    Depleted uranium hexafluoride (DUF{sub 6}) is stored in over 62,000 containment cylinders at the Paducah Gaseous Diffusion Plant (PGDP) in Paducah, Kentucky, and at the Portsmouth Gaseous Diffusion Plant (PORTS) in Portsmouth, Ohio. Over 4,800 of the cylinders at Portsmouth were recently moved there from the East Tennessee Technology Park (ETTP) in Oak Ridge, Tennessee. The cylinders range in age up to 56 years and come in various models, but most are 48-inch diameter 'thin-wall'(312.5 mil) and 'thick-wall' (625 mil) cylinders and 30-inch diameter '30A' (including '30B') cylinders with 1/2-inch (500 mil) walls. Most of the cylinders are carbon steel, and they are subject to corrosion. The United States Department of Energy (DOE) manages the cylinders to maintain them and the DUF{sub 6} they contain. Cylinder management requirements are specified in the System Requirements Document (LMES 1997a), and the activities to fulfill them are specified in the System Engineering Management Plan (LMES 1997b). This report documents activities that address DUF{sub 6} cylinder management requirements involving measuring and forecasting cylinder wall thicknesses. As part of these activities, ultrasonic thickness (UT) measurements are made on samples of cylinders. For each sampled cylinder, multiple measurements are made in an attempt to find, approximately, the minimum wall thickness. Some cylinders have a skirt, which is an extension of the cylinder wall to protect the head (end) and valve. The head/skirt interface crevice is thought to be particularly vulnerable to corrosion, and for some skirted cylinders, in addition to the main body UT measurements, a separate suite of measurements is also made at the head/skirt interface. The main-body and head/skirt minimum thickness data are used to fit models relating minimum thickness to cylinder age, nominal thicknesses, and cylinder functional groups defined in terms of plant site, storage yard

  18. 49 CFR 172.450 - EMPTY label.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false EMPTY label. 172.450 Section 172.450... SECURITY PLANS Labeling § 172.450 EMPTY label. (a) Each EMPTY label, except for size, must be as follows....) in height. (2) The label must be white with black printing. (b) [Reserved] ...

  19. Gastric emptying in gastroesophageal reflux disease

    International Nuclear Information System (INIS)

    Li Lin; Yang Xiaochuan; Kuang Anren; Li Lixia; Ouyang Qin

    2000-01-01

    Objective: The relationship between gastroesophageal reflux disease (GERD) and gastric emptying rate was investigated. Results of endoscopy, 24-hour esophageal pH monitoring were also evaluated. Methods: 15 patients were evaluated with endoscopy, pH monitoring and radionuclide gastric emptying. The results were compared with that of 17 control subjects. Correlations of gastric emptying rate and esophagitis, 24-hour pH monitoring between GERD patients and control subjects were also analyzed. Results: Liquid gastric emptying rate of GERD patients was significantly lower than that of control subjects at 15 and 30 min (P 0.05), but there exhibited a linear correlation between 50% solid emptying time and esophagus pH total score (r=0.643, P<0.05). Conclusions: The results indicate a delayed liquid and solid gastric emptying in GERD patients. There is a linear correlation between 50% solid emptying time and esophagus pH total score. Delayed gastric emptying may be an important factor in the pathogenesis of GERD

  20. Gastric Emptying Time in Acute and Chronic Hepatitis B Patients

    International Nuclear Information System (INIS)

    Lee, Kyung Han; Kim, Ho Jong; Choo, Kil Yeon; Kim, Jung Han; Kim, Jae Myung; Won, Chong Hyun; Park, Gwun Taek; Kim, Seoung Wok

    1992-01-01

    Anorexia, nausea, and vomiting are one of the most frequent symptoms in viral hepatitis patients. These may be due to poorly detoxified substances by dysfunctioned hepatocytes or by gastritis, but the pathophysiology is not totally understood. The symptoms interfere with adequate nutrient intake and are managed by metaclopramide, which accelerates gastric emptying. Thus delayed gastric emptying may well be a contributing factor to such symptoms. To determine such a relationship, we measured gastric emptying time in 11 normal subjects, 9 acute (AVH), and 12 chronic B viral hepatitis (CVH) patients. All were males with a mean age of 23 years. An egg was labeled with 0.5 mCi of 99m Tc-sulfur colloid, fried, then eaten between 2 slices of bread with 100 cc of water. Anterior and posterior images were taken at 20 minute intervals over a 2 hour period. A geometric mean of activity pertaining to the gastric region was measured, and T 1 /2 was calculated from the time activity curve. T 1 /2 for normal the group was 57.8 ± 6.3 minutes while that for the AVH and CVH group was 58.2 ± 8.2 (p=0.40) and 64.1 ± 10.5 (p=0.09), respectively. There was 1 AVH patient and 4 CVH patients with prolonged T 1 /2. Anorexia and nausea was seen in 71% and 46% of the patients, respectively. 80% and 60% of the patients with prolonged T 1 /2 had anorexia and nausea, respectively.

  1. Gastric Emptying Time in Acute and Chronic Hepatitis B Patients

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Han [Capital Armed General Hospital, Seoul (Korea, Republic of); Kim, Ho Jong; Choo, Kil Yeon; Kim, Jung Han; Kim, Jae Myung; Won, Chong Hyun; Park, Gwun Taek; Kim, Seoung Wok [Kwangmyung Seong Ae Hospital, Kwangmyung (Korea, Republic of)

    1992-07-15

    Anorexia, nausea, and vomiting are one of the most frequent symptoms in viral hepatitis patients. These may be due to poorly detoxified substances by dysfunctioned hepatocytes or by gastritis, but the pathophysiology is not totally understood. The symptoms interfere with adequate nutrient intake and are managed by metaclopramide, which accelerates gastric emptying. Thus delayed gastric emptying may well be a contributing factor to such symptoms. To determine such a relationship, we measured gastric emptying time in 11 normal subjects, 9 acute (AVH), and 12 chronic B viral hepatitis (CVH) patients. All were males with a mean age of 23 years. An egg was labeled with 0.5 mCi of {sup 99m}Tc-sulfur colloid, fried, then eaten between 2 slices of bread with 100 cc of water. Anterior and posterior images were taken at 20 minute intervals over a 2 hour period. A geometric mean of activity pertaining to the gastric region was measured, and T{sub 1}/2 was calculated from the time activity curve. T{sub 1}/2 for normal the group was 57.8 +- 6.3 minutes while that for the AVH and CVH group was 58.2 +- 8.2 (p=0.40) and 64.1 +- 10.5 (p=0.09), respectively. There was 1 AVH patient and 4 CVH patients with prolonged T{sub 1}/2. Anorexia and nausea was seen in 71% and 46% of the patients, respectively. 80% and 60% of the patients with prolonged T{sub 1}/2 had anorexia and nausea, respectively.

  2. Testing of the Model 48-14 overpack for UF6 cylinders

    International Nuclear Information System (INIS)

    Stitt, D.H.

    1983-01-01

    Shipment of UF 6 enriched to 1.0% or greater assay 235 U currently is done in either the 30-B overpack or the Paducah tiger overpack. The former contains a 2-1/2 ton cylinder, 30 in. in diameter, while the latter contains a 10-ton cylinder, 48 in. in diameter. There are apparent economy and safety considerations associated with shipping in the larger containers due to the reduced number of shipments and connect and disconnect operations. Further reductions in connect and disconnect operations and shipping costs could be achieved through use of the 14-ton cylinder for shipment of enriched material. With this thought, a program was initiated in 1980 to develop a protective overpack for the Model 48Y cylinder. Two prototype overpacks of wood and stainless steel construction were fabricated. The results from the drop tests and the thermal exposure test are presented

  3. Correction: Electronic structure of the boron fullerene B14 and its silicon derivatives B13Si+, B13Si- and B12Si2: a rationalization using a cylinder model.

    Science.gov (United States)

    Van Duong, Long; Nguyen, Minh Tho

    2016-08-28

    Correction for 'Electronic structure of the boron fullerene B 14 and its silicon derivatives B 13 Si + , B 13 Si - and B 12 Si 2 : a rationalization using a cylinder model' by Long Van Duong et al., Phys. Chem. Chem. Phys., 2016, 18, 17619-17626.

  4. Improvement of the Magnetic Shielding Effects by the Superposition of a Multi-Layered Ferromagnetic Cylinder over an HTS Cylinder: Relationship Between the Shielding Effects and the Layer Number of the Ferromagnetic Cylinder

    International Nuclear Information System (INIS)

    Yasui, K; Tarui, Y; Itoh, M

    2006-01-01

    The idealized magnetic shielded vessel can be realized by making use of a high-critical temperature superconductor (HTS). It is difficult for practical applications, however, to fabricate a shielding vessel that has a high value of the maximum shielded magnetic flux density B s0 . The present authors have improved the value of B s0 for the Bi-Pb-Sr-Ca-Cu-O (BPSCCO) cylinder used as the shielding vessel, by the superposition of a four-layered softiron cylinder over the BPSCCO cylinder, termed the four-layered superimposed cylinder. The B s4 value of 610 x 10 -4 T for the four-layered superimposed cylinder, is found to be about 4 times larger than that of a single-BPSCCO cylinder, and is theoretically analyzed by use of a new analysis method. The experimental values of the maximum shielded magnetic flux density B sn of n-layered superimposed cylinders are found to agree well with those of the theoretical analysis. Experimental results revealed several characteristics of the magnetic shielding within the n-layered superimposed cylinders. Also discussed is the new analysis method for the relationship between the n and B sn

  5. [Electrogastrography and gastric emptying in non organic dyspepsia].

    Science.gov (United States)

    López Gastón, A R; López De Luise, G A; Sarmiento, A

    1996-01-01

    Electrogastrography allows to determinate the dominant frequency of gastric E.C.A. (electrical control activity). The aim was to investigate the gastric E.C.A. in a population of patients suffering from non-organic dispepsia (N.O.D.). Eighteen controls (9 males, 9 females, mean age 46.4 years old, SEM 3.72, range 24-72) and 52 dyspeptic patients (18 males, 34 females, mean age 54.19 years old, SEM 2.38, range 17-86) were studied. Two skin surface electrodes Ag-2ClAg were placed on epigastric area following a probabilistic antral axe. Reference electrode was placed on the right quadrant skin. In 5 patients, recordings with needle and cutaneous electrode were compared. Analogic waves were filtered, digitalized and processed. Signals were analyzed using F.F.T. (Fast Fourier Transformated) Only the predominant frequency in each block was considered, and percentage of total abnormalities on total recording time lesser than 2 c.p.m. or more than 4 c.p.m. was accepted. Recording were taken in fast time during 30 minutes, and 30 minutes after a meal containing 230 Cal. Running spectral analysis with F.F.T. In 43 non-selected patients the gastric emptying time of a mixed meal marked with 99 Tc in the solid phase was studied. 60.45% showed delayed gastric emptying. Mean of fast E.C.A. was 2.99 c.p.m. in controls, Vs 3.34 c.p.m. in dispeptic patients (p > 0.001). In the post-prandial period, mean of E.C.A. was 3.53 c.p.m. in N.O.D., and these differences were not significatives ("t", NS). 22% of controls showed isolated periods of tachygastria, but never more than 8% of the total recording time. It was seen seven six and forty five percent of arrhythmias were observed (71.15% tachygastria, 4.76% bradygastria, and 19.23% mixed) during post prandial recording in N.O.D. 48% of tachygastrias were between the range 30-60% of the time recording. Ninety six and one percent of patients with abnormal gastric emptying had gastric arrhythmias (0.05 > p > 0.02) Vs 50% in patients with

  6. Powder alignment system for anisotropic bonded NdFeB Halbach cylinders \\ud

    OpenAIRE

    Zhu, Z.Q.; Xia, Z.P.; Atallah, K.; Jewell, G.W.; Howe, D.

    2000-01-01

    A Halbach cylinder, fabricated from pre-magnetized sintered NdFeB magnet segments, is proposed for the powder aligning system during the compression or injection moulding of anisotropic bonded Halbach oriented NdFeB ring magnets. The influence of leading design parameters of the powder aligning system, viz. the number of magnet segments per pole, their axial length and radial thickness, and their clearance from the mould, is investigated by finite element analysis, and validated experimentally

  7. A linear motor and compact cylinder-piston driver for left ventricular bypass.

    Science.gov (United States)

    Qian, K X

    1990-01-01

    A simple, portable, reliable and noise-free pneumatic driver has been developed. It consists of a linear motor attached to a cylinder piston, in one unit. The motor coil is directly wound on the cylinder, and the permanent magnet is fixed to the piston. As a continuous voltage square wave is applied to the coil, the cylinder reciprocates on the piston periodically, producing air pressure and vacuum alternately. In conjunction with a locally made diaphragm pump, the driver was tested in vitro and in vivo. Results demonstrated that the device could drive the diaphragm pump and so support the circulation of an experimental animal. The driver weighs 12 kg. For 200 mmHg air pressure and -80 mmHg vacuum the power consumed is 30 W. Its noise is about 30 dB, less than that of an artificial valve and pump.

  8. Empty conformers of HLA-B preferentially bind CD8 and regulate CD8+ T cell function.

    Science.gov (United States)

    Geng, Jie; Altman, John D; Krishnakumar, Sujatha; Raghavan, Malini

    2018-05-09

    When complexed with antigenic peptides, human leukocyte antigen (HLA) class I (HLA-I) molecules initiate CD8 + T cell responses via interaction with the T cell receptor (TCR) and co-receptor CD8. Peptides are generally critical for the stable cell surface expression of HLA-I molecules. However, for HLA-I alleles such as HLA-B*35:01, peptide-deficient (empty) heterodimers are thermostable and detectable on the cell surface. Additionally, peptide-deficient HLA-B*35:01 tetramers preferentially bind CD8 and to a majority of blood-derived CD8 + T cells via a CD8-dependent binding mode. Further functional studies reveal that peptide-deficient conformers of HLA-B*35:01 do not directly activate CD8 + T cells, but accumulate at the immunological synapse in antigen-induced responses, and enhance cognate peptide-induced cell adhesion and CD8 + T cell activation. Together, these findings indicate that HLA-I peptide occupancy influences CD8 binding affinity, and reveal a new set of regulators of CD8 + T cell activation, mediated by the binding of empty HLA-I to CD8. © 2018, Geng et al.

  9. Effect of nifedipine on gastric emptying in normal subjects

    Energy Technology Data Exchange (ETDEWEB)

    Traube, M.; Lange, R.C.; McAllister, R.G.; McCallum, R.W.

    1985-05-01

    Nifedipine (N) inhibits calcium entry into smooth muscle cells and relaxes esophageal smooth muscle. The authors studied N's effect on gastric emptying of liquids and solids. Ten normal subjects underwent radionuclide (In-111-DTPA in water and Tc-99m-sulfur colloid tagged to chicken liver) emptying tests with and without 30 mg N given orally 20 min prior to meal ingestion. Peak plasma N levels were either 30 or 60 min after drug dosing and showed a 3-fold variation (low 145 ng/ml, high 434 ng/ml). Both mean N levels and integral concentration time values were twice as high as those obtained after 30 mg sublingual dosing in normals previously studied in our lab. The authors conclude that plasma N levels which are associated with significant esophageal motility effects do not change gastric emptying in normal subjects. The data also show that N levels are greater after oral than sublingual dosing of 30 mg in normal subjects.

  10. Effect of nifedipine on gastric emptying in normal subjects

    International Nuclear Information System (INIS)

    Traube, M.; Lange, R.C.; McAllister, R.G.; McCallum, R.W.

    1985-01-01

    Nifedipine (N) inhibits calcium entry into smooth muscle cells and relaxes esophageal smooth muscle. The authors studied N's effect on gastric emptying of liquids and solids. Ten normal subjects underwent radionuclide (In-111-DTPA in water and Tc-99m-sulfur colloid tagged to chicken liver) emptying tests with and without 30 mg N given orally 20 min prior to meal ingestion. Peak plasma N levels were either 30 or 60 min after drug dosing and showed a 3-fold variation (low 145 ng/ml, high 434 ng/ml). Both mean N levels and integral concentration time values were twice as high as those obtained after 30 mg sublingual dosing in normals previously studied in our lab. The authors conclude that plasma N levels which are associated with significant esophageal motility effects do not change gastric emptying in normal subjects. The data also show that N levels are greater after oral than sublingual dosing of 30 mg in normal subjects

  11. Normal range of gastric emptying in children

    International Nuclear Information System (INIS)

    Thomas, P.; Collins, C.; Francis, L.; Henry, R.; O'Loughlin, E.; John Hunter Children's Hospital, Newcastle, NSW

    1999-01-01

    Full text: As part of a larger study looking at gastric emptying times in cystic fibrosis, we assessed the normal range of gastric emptying in a control group of children. Thirteen children (8 girls, 5 boys) aged 4-15 years (mean 10) were studied. Excluded were children with a history of relevant gastrointestinal medical or surgical disease, egg allergy or medication affecting gastric emptying. Imaging was performed at 08.00 h after an overnight fast. The test meal was consumed in under 15 min and comprised one 50 g egg, 80 g commercial pancake mix, 10 ml of polyunsaturated oil, 40 ml of water and 30 g of jam. The meal was labelled with 99 Tc m -macroaggregates of albumin. Water (150 ml) was also consumed with the test meal. One minute images of 128 x 128 were acquired over the anterior and posterior projections every 5 min for 30 min, then every 15 min until 90 min with a final image at 120 min. Subjects remained supine for the first 60 min, after which they were allowed to walk around. A time-activity curve was generated using the geometric mean of anterior and posterior activity. The half emptying time ranged from 55 to 107 min (mean 79, ± 2 standard deviations 43-115). Lag time (time for 5% to leave stomach) ranged from 2 to 26 min (mean 10). The percent emptied at 60 min ranged from 47 to 73% (mean 63%). There was no correlation of half emptying time with age. The normal reference range for a test meal of pancakes has been established for 13 normal children

  12. UF{sub 6} cylinder inspections at PGDP

    Energy Technology Data Exchange (ETDEWEB)

    Lamb, G.W.; Whinnery, W.N. [Martin Marietta Energy Systems, Inc., Paducah, KY (United States)

    1991-12-31

    Routine inspections of all UF{sub 6} cylinders at the Paducah Gaseous Diffusion Plant have been mandated by the Department of Energy. A specific UF{sub 6} cylinder inspection procedure for what items to inspect and training for the operators prior to inspection duty are described. The layout of the cylinder yards and the forms used in the inspections are shown. The large number of cylinders (>30,000) to inspect and the schedule for completion on the mandated time table are discussed. Results of the inspections and the actions to correct the deficiencies are explained. Future inspections and movement of cylinders for relocation of certain cylinder yards are defined.

  13. Small intestinal emptying time in normal Beagle dogs: a contrast radiographic study

    International Nuclear Information System (INIS)

    Miyabayashi, T.; Morgan, J.P.; Atilola, M.A.O.; Muhumuza, L.

    1986-01-01

    Gastric emptying time and small intestinal transit time in dogs are frequently discussed. However, it is often of interest to the radiologist to know what normal small intestinal emptying times should be. A total of 15 upper gastrointestinal studies was performed on five internal parasite-free, normal, standard Beagle dogs with three studies on each dog, 6 days apart. The ages and weights of the dogs ranged from 2–8 years and from 12.4–13.7 kg, respectively. Following 24-hour fasting, a dose of 10 ml/kg bw of 60% wt/vol barium sulfate suspension was administered through a stomach tube. Then, sequential radiographs were made at 30-minute intervals until the entire contrast medium column was in the colon and cecum. The mean, standard deviation, and range of gastric emptying time, small intestinal transit time, and small intestinal emptying time were 76 ± 16.7 (30–120), 73 ± 16.4 (30–120), and 214 ± 25.1 (180–300) minutes, respectively. This study offers the possibility that small intestinal emptying time may be used to further evaluate patients with suspected small intestinal partial obstruction, pseudo-obstruction, ischemia, or lymphangiectasia

  14. Simultaneous gastric emptying of two solid foods

    International Nuclear Information System (INIS)

    Weiner, K.; Graham, L.S.; Reedy, T.; Elashoff, J.; Meyer, J.H.

    1981-01-01

    A variety of radionuclide-labeled, solid foods have been used to measure gastric emptying. Implicit is the idea that the nuclide label identifies the rate of emptying of meal contents. The present studies tested whether different foods empty from the human stomach at different rates. Eight volunteers were fed meals of 200 ml of water + 213 g of beef stew + 52 g of chicken liver, with half the liver as 0.25-mm particles and half as 10-mm chunks, labeled with /sup 99m/Tc and /sup 113m/In, respectively, or the reverse. Another 8 subjects ingested 200 ml of water + 75 g of noodles, labeled with /sup 123/I, + 30 g of liver, labeled with /sup 113/In. Gastric emptying of each radionuclide was determined for 3 h by measuring the decline of counts in the gastric region of interest, using an Ohio Nuclear S410 gamma camera interfaced to a DEC computer. In each case, appropriate corrections were made for nuclear decay, down-scatter from /sup 113m/In, and septal penetration. Seven of 8 subjects emptied 0.25-mm liver particles more quickly than 10-mm chunks of liver, while 1 subject emptied the two sizes of liver at the same rate. The t 1/2 for the 0.25-mm liver was 70 +/- 10 min; and for the 10-mm liver, 117 +/- 19 min (p less than 0.05). Six of 8 subjects emptied noodles much faster than liver, while 2 emptied the two foods at similar rates. The t 1/2 for the noodles was 52 +/- 8 min; and for the liver, 82 +/- 5 min (p less than 0.02). Since different foods in the same meal were found to empty at different rates, we conclude the gastric emptying of every food in a meal is not accurately represented by the emptying of a single, nuclide-labeled food. The different t 1/2s for the emptying of 10-mm liver in the two meals (p less than 0.05) probably reflected the influence of other meal components on gastric motility

  15. Simultaneous gastric emptying of two solid foods

    Energy Technology Data Exchange (ETDEWEB)

    Weiner, K.; Graham, L.S.; Reedy, T.; Elashoff, J.; Meyer, J.H.

    1981-08-01

    A variety of radionuclide-labeled, solid foods have been used to measure gastric emptying. Implicit is the idea that the nuclide label identifies the rate of emptying of meal contents. The present studies tested whether different foods empty from the human stomach at different rates. Eight volunteers were fed meals of 200 ml of water + 213 g of beef stew + 52 g of chicken liver, with half the liver as 0.25-mm particles and half as 10-mm chunks, labeled with /sup 99m/Tc and /sup 113m/In, respectively, or the reverse. Another 8 subjects ingested 200 ml of water + 75 g of noodles, labeled with /sup 123/I, + 30 g of liver, labeled with /sup 113/In. Gastric emptying of each radionuclide was determined for 3 h by measuring the decline of counts in the gastric region of interest, using an Ohio Nuclear S410 gamma camera interfaced to a DEC computer. In each case, appropriate corrections were made for nuclear decay, down-scatter from /sup 113m/In, and septal penetration. Seven of 8 subjects emptied 0.25-mm liver particles more quickly than 10-mm chunks of liver, while 1 subject emptied the two sizes of liver at the same rate. The t 1/2 for the 0.25-mm liver was 70 +/- 10 min; and for the 10-mm liver, 117 +/- 19 min (p less than 0.05). Six of 8 subjects emptied noodles much faster than liver, while 2 emptied the two foods at similar rates. The t 1/2 for the noodles was 52 +/- 8 min; and for the liver, 82 +/- 5 min (p less than 0.02). Since different foods in the same meal were found to empty at different rates, we conclude the gastric emptying of every food in a meal is not accurately represented by the emptying of a single, nuclide-labeled food. The different t 1/2s for the emptying of 10-mm liver in the two meals (p less than 0.05) probably reflected the influence of other meal components on gastric motility.

  16. Natural phenomena evaluations of the K-25 site UF6 cylinder storage yards

    International Nuclear Information System (INIS)

    Fricke, K.E.

    1996-01-01

    The K-25 Site UF 6 cylinder storage yards are used for the temporary storage of UF 6 normal assay cylinders and long-term storage of other UF 6 cylinders. The K-25 Site UF 6 cylinder storage yards consist of six on-site areas: K-1066-B, K-1066-E, K-1066-F, K-1066-J, K-1066-K and K-1066-L. There are no permanent structures erected on the cylinder yards, except for five portable buildings. The operating contractor for the K-25 Site is preparing a Safety Analysis Report (SAR) to examine the safety related aspects of the K-25 Site UF 6 cylinder storage yards. The SAR preparation encompasses many tasks terminating in consequence analysis for the release of gaseous and liquid UF 6 , one of which is the evaluation of natural phenomena threats, such as earthquakes, floods, and winds. In support of the SAR, the six active cylinder storage yards were evaluated for vulnerabilities to natural phenomena, earthquakes, high winds and tornados, tornado-generated missiles, floods (local and regional), and lightning. This report summarizes those studies. 30 refs

  17. Assessment of Reusing 14-Ton, Thin-Wall, Depleted UF6 Cylinders as LLW Disposal Containers

    International Nuclear Information System (INIS)

    O'Connor, D.G.; Poole, A.B.; Shelton, J.H.

    2000-01-01

    Approximately 700,000 MT of DUF 6 is stored, or will be produced under a current agreement with the USEC, at the Paducah site in Kentucky, Portsmouth site in Ohio, and ETTP site in Tennessee. On July 21, 1998, the 105th Congress approved Public Law 105-204, which directed that facilities be built at the Kentucky and Ohio sites to convert DUF 6 to a stable form for disposition. On July 6, 1999, the Department of Energy (DOE) issued the ''Final Plan for the Conversion of Depleted Uranium Hexafluoride as Required by Public Law 105-204'', in which DOE committed to develop a ''Depleted Uranium Hexafluoride Materials Use Roadmap''. On September 1,2000, DOE issued the ''Draft Depleted Uranium Hexafluoride Materials Use Roadmap'' (Roadmap), which provides alternate paths for the long-term storage, beneficial use, and eventual disposition of each product form and material that will result from the DUF 6 conversion activity. One of the paths being considered for DUF 6 cylinders is to reuse the empty cylinders as containers to transport and dispose of LLW, including the converted DU. The Roadmap provides results of the many alternate uses and disposal paths for conversion products and the empty DUF 6 storage cylinders. As a part of the Roadmap, evaluations were conducted of cost savings, technical maturity, barriers to implementation, and other impacts. Results of these evaluations indicate that using the DUF 6 j storage cylinders as LLW disposal containers could provide moderate cost savings due to the avoided cost of purchasing LLW packages and the avoided cost of disposing of the cylinders. No significant technical or institutional .issues were identified that.would make using cylinders as LLW packages less effective than other disposition paths. Over 58,000 cylinders have been used, or will be used, to store DUF 6 . Over 5 1,000 of those cylinders are 14TTW cylinders with a nominal wall thickness of 5/16-m (0.79 cm). These- 14TTW cylinders, which have a nominal diameter

  18. A simple labeled test meal for the evaluation of gastric emptying

    International Nuclear Information System (INIS)

    Ishii, Keita; Tanabe, Satoshi; Mitsuhashi, Toshiharu; Saigenji, Katsunori

    1994-01-01

    We developed a simple test meal for the evaluation of gastric emptying. Preparation of a test meal for routine clinical use in institutions should be as simple as possible. The newly developed test meal consists of instant noodles labeled with 37 MBq (1 mCi) technetium-99m and does not require the use of cooking utensils. The test meal was given with drinking water (180 ml) to healthy adult volunteers (6 men, 34.5±2.2 years old) and gastric emptying was measured at 0, 5, 10, 15, 30, 45, 60, 80, 100, 120 minutes after the end of the meal, and results were compared with those derived without drinking water. The emptying pattern of the test meal with water exhibited an exponential pattern typical of a liquid meal, and that without water formed a linear pattern after an initial lag phase in keeping with gastric emptying of a solid meal. In addition, the test meal was given to 11 patients of diabetic gastroparesis (5 men, 6 women, 50.4±4.5 years old), and gastric emptying was measured. At each period evaluated, emptying was significantly slower in diabetic gastroparesis than in healthy controls (6 men, 1 woman, 32.1±3.0 years old). These results show that the test meal is reliable and applicable to the clinical assessment of gastric emptying, while fulfilling the need for simplicity. (author)

  19. Delayed gastric emptying in children with chronic constipation and fecal impaction

    International Nuclear Information System (INIS)

    Baracat, M.L.C.M.; Daher, S.F.; Brunetto, S.Q.; Etchebehere, E.C.S.C.; Santos, A.O.; Ramos, C.D.; Camargo, E.E.; Pinto, E.A.L.C.; Silva, J.M.B.

    2002-01-01

    Post-prandial upper abdominal symptoms such as nausea, fullness and early satiety in constipated children may be associated with delayed gastric emptying. Aim: To evaluate the gastric emptying in children with post-prandial upper abdominal symptoms. Materials and Methods: Gastric emptying studies were performed in 12 children with functional constipation (mean age 9 years; mean duration of symptoms: 5.5 years), fecal impaction and soiling. In 12 of them the studies were performed only before fecal impaction removal and in 7 of them the study was repeated after impaction removal and recovery from constipation. After an overnight fast, the patients received 300 ml/m 2 of water added to 37 MBq of 99m Tc-sulfur colloid. Images were acquired in a camera-computer system with a low energy all purpose collimator. Images were acquired at 1 minute per frame for 30 minutes. When gastric emptying was delayed for more than 30 minutes, additional static images with 500,000 counts were performed for no more than 1 hour until a T1/2 was obtained. Results: Gastric emptying was delayed (21.4 ± 7 minutes; normal 12 ± 3 minutes) in 10/12 patients studied prior to fecal impaction removal. In the group of seven patients who repeated the study after fecal impaction removal, gastric emptying remained prolonged (22 ±7.9 minutes). There was no statistically significant difference between the gastric emptying time before and after fecal impaction removal (p 0,612; Wilcoxon test). Conclusion: The gastric emptying time of a liquid test meal was delayed in constipated children before and after fecal impaction removal. Maintenance of prolonged emptying time after impaction removal and recovery from constipation may indicate an alteration in gastrointestinal motility

  20. Gastric emptying measurements: delayed and complex emptying patterns without appropriate correction

    Energy Technology Data Exchange (ETDEWEB)

    Moore, J.G.; Christian, P.E.; Taylor, A.T.; Alazraki, N.

    1985-10-01

    Anteriorly acquired and geometric mean corrected gastric emptying curves of solids and liquid isotopic-labeled meals were compared in 37 subjects given 61 meals of three different sizes. Anterior data alone consistently and significantly underestimated solid-phase gastric emptying rates with all meal sizes when compared to geometric mean acquired data. However, with liquids there were only slight differences between anterior and anterior and posterior geometric mean corrected emptying-rates. The difference probably reflects greater attenuation of the 140 kev photon of /sup 99m/Tc compared to the 247 keV photon of In. With anterior data alone, an apparent early delay in emptying of solids was present with all meal sizes and the resultant emptying curves were nonlinear in shape. Geometric mean correction resulted in the linearization of the solid-phase emptying curves and essentially eliminated the apparent delay in emptying or lag phase noted with the anterior data alone. Based on our results, geometric mean correction techniques are necessary for accurate assessment of radioisotopic-labeled solid meals.

  1. Fire testing of bare uranium hexafluoride cylinders

    Energy Technology Data Exchange (ETDEWEB)

    Pryor, W.A. [PAI Corp., Oak Rige, TN (United States)

    1991-12-31

    In 1965, the Oak Ridge Gaseous Diffusion Plant (ORGDP), now the K-25 Site, conducted a series of tests in which bare cylinders of uranium hexafluoride (UF{sub 6}) were exposed to engulfing oil fires for the US Atomic Energy Commission (AEC), now the US Department of Energy (DOE). The tests are described and the results, conclusions, and observations are presented. Two each of the following types of cylinders were tested: 3.5-in.-diam {times} 7.5-in.-long cylinders of Monel (Harshaw), 5.0-in.-diam {times} 30-in.-long cylinders of Monel, and 8-in.-diam {times} 48-in.-long cylinders of nickel. The cylinders were filled approximately to the standard UF{sub 6} fill limits of 5, 55, and 250 lb, respectively, with a U-235 content of 0.22%. The 5-in.- and 8-in.-diam cylinders were tested individually with and without their metal valve covers. For the 3.5-in.-diam Harshaw cylinders and the 5.0-in.-diam cylinder without a valve cover the valves failed and UF{sub 6} was released. The remaining cylinders ruptured explosively in time intervals ranging from about 8.5 to 11 min.

  2. Fire testing of bare uranium hexafluoride cylinders

    Energy Technology Data Exchange (ETDEWEB)

    Pryor, W.A. [PAI Corp., Oak Ridge, TN (United States)

    1991-12-31

    In 1965, the Oak Ridge Gaseous Diffusion Plant (ORGDP), now the K-25 Site, conducted a series of tests in which bare cylinders of uranium hexafluoride (UF{sub 6}) were exposed to engulfing oil fires for the US Atomic Energy Commission (AEC), now the US Department of Energy (DOE). The tests are described and the results, conclusions, and observations are presented. Two each of the following types of cylinders were tested: 3.5-in.-diam {times} 7.5-in.-long cylinders of Monel (Harshaw), 5.0-in.-diam {times} x 30-in.-long cylinders of Monel, and 8-in.-diam {times} 48-in.-long cylinders of nickel. The cylinders were filled approximately to the standard UF{sub 6} fill limits of 5, 55, and 250 lb, respectively, with a U-235 content of 0.22%. The 5-in.- and 8-in.-diam cylinders were tested individually with and without their metal valve covers. For the 3.5-in.-diam Harshaw cylinders and the 5.0-in.-diam cylinder without a valve cover, the valves failed and UF{sub 6} was released. The remaining 6 cylinders ruptured explosively in time intervals ranging from about 8.5 to 11 min.

  3. Gastric emptying of solids and liquids in obesity.

    Science.gov (United States)

    Glasbrenner, B; Pieramico, O; Brecht-Krauss, D; Baur, M; Malfertheiner, P

    1993-07-01

    The purpose of this study was to determine whether obese patients have different rates of solid and liquid gastric emptying compared to healthy controls. Twenty-four obese patients (7 males, 17 females) were investigated prior to dietary restriction. The patients had a weight excess above ideal weight ranging from 25% to 216% (mean weight 118.1 +/- 6.5 kg). The control group consisted of 8 healthy subjects (4 males, 4 females), within 10% of the ideal weight. The solid phase of the test meal consisted of 40 g bread, 30 g ham, 10 g margarine, and two scrambled eggs labeled with 99mTc. For the liquid phase, 200 ml orange juice was labeled with 201Tl. Three-minute counts of both tracers were taken for 106 min using a large field-of-view gamma camera. In obese patients, a significantly shortened lag phase for the emptying of solids was observed (27.0 +/- 3.3 versus 38.4 +/- 4.1 min; P < 0.05). Half-emptying time (105.9 +/- 6.7 versus 100.7 +/- 5.7 min), emptying rate (0.60 +/- 0.04 versus 0.71 +/- 0.07%/min), and total emptying of solids (49.4 +/- 3.6 versus 50.5 +/- 5.0%) were not different from controls. Obese subjects had a trend to slowed liquid emptying (half-time 82.7 +/- 4.8 versus 69.9 +/- 6.9 min; emptying rate 0.59 +/- 0.03 versus 0.65 +/- 0.03%/min; total emptying 59.8 +/- 2.9 versus 66.0 +/- 3.3%), but this was not statistically significant. There was no correlation between weight or body surface area and rate of solid or liquid gastric emptying.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Analytic solutions of del x B = αB in a straight cylinder with α = α(r)

    International Nuclear Information System (INIS)

    Ling, K.M.; Baker, D.A.

    1985-06-01

    Analytic solutions of del x B = αB are presented for reversed field pinch (RFP) configurations in a straight cylinder with α = α(r) where r is the radial coordinate. The function α(r) is a smooth function of r vanishing at the wall (r = a). Closed form parametric formulas for a family of F-THETA curves are obtained from the analytic, cylindrically symmetric, force-free fields. These formulas can be used to fit experimental F-THETA curves and hence facilitate comparison between the various existing RFP experiments. The advantage of these formulas lies in the fact that they are expressed in terms of easily obtainable Bessel functions of the first kind, eliminating the need of mumerical integration. Results of the least-square fits of two typical ZT-40M shots are presented

  5. Gallbladder emptying in chronic pancreatitis a scintigraphic evaluation

    International Nuclear Information System (INIS)

    Buchpiguel, C.A.; Pedroso, M.; Sapioenza, M.; Watanabe, T.; Costa, P.; Yamashiba, C.; Melo, I.; Garcez, A.

    1997-01-01

    Full text: Our purpose was to evaluate the gallbladder (GB) emptying in pts with chronic pancreatitis and to determine whether or not the use of pancreatic extract has an impact in improving that function. The GB emptying was evaluated in 11 patients (pts) with mild to moderate chronic pancreatitis, and in 10 normal volunteers. Pts and controls who presented any kind of condition that could interfere with the gastric or gallbladder emptying were excluded. The GB ejection fraction was calculated at 30, 45, and 60 minutes after a standardized fatty meal ingestion. In the pts group, this evaluation was obtained in two different periods of time, without and with the addition of pancreatic extract. The gastric emptying was previously determined in all patients and controls with Technetium-99m-sulfur colloid mixed in the same fatty meal used for the hepatobiliary scans. The results disclosed that the GB ejection fraction at 60 minutes was significantly lower in patients compared to controls ( 0,05). The gastric emptying was similar between the two groups (p>0,05). In conclusion, mild to moderate chronic pancreatitis is associated with GB function impairment. Our results suggest that the delay in GB emptying does not depend exclusively on the alteration in the intestinal phase of the GB stimulation, but may be a result of multiple other factors

  6. Gastric-emptying tests

    International Nuclear Information System (INIS)

    Brown, M.L.; Malagelada, J.R.

    1983-01-01

    Mechanisms regulating gastric emptying have been characterized through many decades of experimental work. Both central and peripheral mechanisms are important. Central mechanisms are related to the center of vomiting and are probably influenced by psychologic and emotional factors. Peripheral mechanisms are located at both sides of the pylorus. Gastric mechanisms are stimulatory and are triggered mainly by distention of the stomach, although hormonal mechanisms may also participate (gastrin). However, with complex, nutrient-containing meals, the intragastric volume is not the primary determinant of gastric emptying. Inhibitory mechanisms of the gut are more important. The key factors are the pH, osmolality, and nutrient content of the chyme being emptied into the duodenum. Osmotic and pH-sensitive receptors are thought to reside in the duodenum. On the other hand, receptors triggered by nutrients extend much more distally into the duodenum and are sensitive to nutrient composition and load. Protein, carbohydrates, and lipids all inhibit gastric emptying, although the lipids are probably the most potent inhibitors. If the duodenal load or the characteristics of the emptying material are not adequate, inhibitory mechanisms will reduce gastric emptying at the expense of expanding the intragastric volume. It is therefore not possible to dissociate postprandial gastric emptying from postprandial gastric secretion

  7. Assessment of gastric emptying in normal subjects with sucralfate (Carafate) and Amphojel

    International Nuclear Information System (INIS)

    Marano, A.R.; Prokop, E.K.; Caride, V.J.; McCallum, R.

    1984-01-01

    Aluminum-containing antacids (e.g Amphojel) and aluminum-containing compounds such as sucralfate (Carafate) have been shown in animal and human studies to delay gastric emptying, and are one proposed mechanism of action for healing of duodenal ulcers. Therefore, the authors designed a study to study the effects of Carafate and Amphojel on gastric emptying. Ten normal volunteers of mean age 27 years with no previous history of upper gastrointestinal diseases were studied. For each test the subject ingested a meal composed of 30gm of cooked chicken liver injected with lmCi of 99m-Tc-S-C, mixed with 7.5 oz. of beef stew, and eaten with 4 oz. of water labeled with 100μCi of 111-In-DTPA. Immediately after ingestion of the meal, the subject was placed supine under a gamma camera. Gastric emptying (GE) was expressed as percent emptied. On separate days the subject was given either lgm of Carafate (190mg Al/gm) or placebo in a double blind fashion one hour prior to the test meal. On the third day, each subject was given 30cc of Amphojel (105mg Al/5cc) followed 30 minutes later by the test meal. GE at 2 hours for the solid meal was 60%, 69%, and 54% and 79%, 86% and 68% at 3 hours for placebo, Carafate, and Amphojel respectively. A small but not significant difference in gastric emptying between Amphojel and placebo was seen from 2 to 3 hours. For the liquid meal approximately 90% emptying was present at 1 hour for all three studies. Further studies are needed to determine whether these medications administered in the standard doses given here may affect gastric emptying in duodenal ulcer patients

  8. Assessment of gastric emptying in normal subjects with sucralfate (Carafate) and Amphojel

    Energy Technology Data Exchange (ETDEWEB)

    Marano, A.R.; Prokop, E.K.; Caride, V.J.; McCallum, R.

    1984-01-01

    Aluminum-containing antacids (e.g Amphojel) and aluminum-containing compounds such as sucralfate (Carafate) have been shown in animal and human studies to delay gastric emptying, and are one proposed mechanism of action for healing of duodenal ulcers. Therefore, the authors designed a study to study the effects of Carafate and Amphojel on gastric emptying. Ten normal volunteers of mean age 27 years with no previous history of upper gastrointestinal diseases were studied. For each test the subject ingested a meal composed of 30gm of cooked chicken liver injected with lmCi of 99m-Tc-S-C, mixed with 7.5 oz. of beef stew, and eaten with 4 oz. of water labeled with 100..mu..Ci of 111-In-DTPA. Immediately after ingestion of the meal, the subject was placed supine under a gamma camera. Gastric emptying (GE) was expressed as percent emptied. On separate days the subject was given either lgm of Carafate (190mg Al/gm) or placebo in a double blind fashion one hour prior to the test meal. On the third day, each subject was given 30cc of Amphojel (105mg Al/5cc) followed 30 minutes later by the test meal. GE at 2 hours for the solid meal was 60%, 69%, and 54% and 79%, 86% and 68% at 3 hours for placebo, Carafate, and Amphojel respectively. A small but not significant difference in gastric emptying between Amphojel and placebo was seen from 2 to 3 hours. For the liquid meal approximately 90% emptying was present at 1 hour for all three studies. Further studies are needed to determine whether these medications administered in the standard doses given here may affect gastric emptying in duodenal ulcer patients.

  9. [Intragastric utilization of antacids following meals in relation to stomach emptying].

    Science.gov (United States)

    Lux, G; Hartog, C; Ruppin, H; Lederer, P; Schmitt, W

    1983-03-01

    Gastric acid secretion and gastric emptying rate was measured using double marker method and continuous titration of a liquid peptone test meal. Titration rate was significantly reduced by 30 ml of an aluminiumhydroxide- and magnesiumhydroxide containing antacid compound (Maalox). Acidity of gastric contents was reduced over a period of 48.4 +/- 9.1 min (mean +/- SD; endpoint of titration pH 5.5) and 77.6 +/- 2.0 min (pH 3.5) (p less than 0.05). The histamine H2-receptor blocker Ranitidine (0.25 mg/kg b.w.) and the antimuscarinic agent Pirenzepine reduced titrable gastric acid secretion in a similar range, as far as the observation period of 90 min is concerned. Biosorbin MCT, a formula diet, stimulated gastric acid secretion half the amount of gastric acid secretion stimulated by the peptone meal. Gastric emptying rate was significantly reduced by formula diet, but not by either of the other compounds.

  10. Investigation of the thermal behavior of 2 1/2 ton cylinder protective overpack

    International Nuclear Information System (INIS)

    Park, S.H.

    1988-01-01

    UF 6 cylinders containing reactor grade enriched uranium are transported in protective overpacks. Recently, the design of the 2 1/2 ton UF 6 cylinder overpack was modified to insure the safety of the cylinder inside the overpack. Modifications include a continuous stainless steel liner from the outer surface to the inner surface of the overpack and step joints between the upper and lower halves of the overpack. The effects of a continuous stainless steel liner and moisture in the insulation layer of a UF 6 cylinder protective overpack were investigated with a numerical code. Results were compared with limited available field data. The purpose of comparing the numerical results with field data is to insure the validity of the numerical analysis and the physical properties used in the analysis. The study indicates that the continuous stainless steel liner did not influence the heat transfer rate much from the outer surface of the overpack to the 30B cylinder inside. The effect of step joints was not modeled due to the difficulty of quantifying the leakage rate through the gap. With a continuous stainless steel liner from the outside of the overpack to the inside, the overpack satisfies the thermal design criteria of protecting the cylinder inside for a minimum of 30 minutes when the overpack is exposed to a fire. The effect of moisture inside the insulation layer in the overpack is to reduce the energy to the cylinder with its high thermal capacity. The high pressure steam generated from the moisture will be relieved externally through the vent holes on the outer surface of the overpack. Although these holes are sealed after the overpack is dried, the plug sealing the holes will melt when the overpack is exposed to a fire

  11. Stabilization of flow past a rounded cylinder

    Science.gov (United States)

    Samtaney, Ravi; Zhang, Wei

    2016-11-01

    We perform global linear stability analysis on low-Re flow past a rounded cylinder. The cylinder corners are rounded with a radius R, normalized as R+ = R / D where D is the cylinder diameter, and its effect on the flow stability characteristics is investigated. We compute the critical Reynolds number (Recr) for the onset of first instability, and quantify the perturbation growth rate for the super-critical flows. It is found that the flow can be stabilized by partially rounding the cylinder. Compared with the square and circular cylinders, the partially rounded cylinder has a higher Recr , attaining a maximum at around R+ = 0 . 30 , and the perturbation growth rate of the super-critical flows is reduced for Re R+ -> 0 . 00), while only the near-wake backflow is crucial for circular-like cylinders (R+ -> 0 . 50). The stability analysis results are also verified with those of the direct simulations and very good agreement is achieved. Supported by the KAUST Office of Competitive Research Funds under Award No. URF/1/1394-01. The supercomputer Shaheen at KAUST was utilized for the simulations.

  12. Image analysis of moving seeds in an indented cylinder

    DEFF Research Database (Denmark)

    Buus, Ole; Jørgensen, Johannes Ravn

    2010-01-01

    inspection in seed cleaning equipment. A prototype of an indented cylinder will be constructed. To make it more dynamic, the cylinder itself will be manufactured using 3D printing technology. The input will come either from 3D scans of existing cylinders or by defining their topology using parametric B...

  13. Monte carlo feasibility study of an active neutron assay technique for full-volume UF{sub 6} cylinder assay using a correlated interrogation source

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Karen A., E-mail: kamiller@lanl.gov [Los Alamos National Laboratory, Los Alamos, P.O. Box 1663 MS E540, NM 87545 (United States); Menlove, Howard O.; Swinhoe, Martyn T.; Marlow, Johnna B. [Los Alamos National Laboratory, Los Alamos, P.O. Box 1663 MS E540, NM 87545 (United States)

    2013-03-01

    Uranium cylinder assay plays an important role in the nuclear material accounting at gas centrifuge enrichment plants. The Passive Neutron Enrichment Meter (PNEM) was designed to determine uranium mass and enrichment in 30B and 48Y cylinders using total neutron and coincidence counting in the passive mode. 30B and 48Y cylinders are used to hold bulk UF{sub 6} feed, product, and tails at enrichment plants. In this paper, we report the results of a Monte-Carlo-based feasibility study for an active uranium cylinder assay system based on the PNEM design. There are many advantages of the active technique such as a shortened count time and a more direct measure of {sup 235}U content. The active system is based on a modified PNEM design and uses a {sup 252}Cf source as the correlated, active interrogation source. We show through comparison with a random AmLi source of equal strength how the use of a correlated driver significantly boosts the active signal and reduces the statistical uncertainty. We also discuss ways in which an active uranium cylinder assay system can be optimized to minimize background from {sup 238}U fast-neutron induced fission and direct counts from the interrogation source.

  14. Study on confirmation of Solid-Meal Lag Phase of Gastric Emptying

    International Nuclear Information System (INIS)

    Lee, Ji Young; Lee, Kyoung Soo; Kim, Chang Guhn; Juhng, Seon Kwan; Won, Jong Jin; Nah, Yong Ho

    1991-01-01

    The purpose of this study was to examine the existence of a lag phase of gastric emptying of solid meals. We studied solid phase gastric emptying in 26 normal subject using continuous data acquisition for 30 minutes. Each ingested a 300 g meal containing 99m Tc-labeled scrambled egg (solid 150 g, milk 150 ml). Lag phase was determined by 1) inspection of the gastric emptying curve 2) time to a 2% decrease in stomach activity 3) the time of visual appearance of duodenal activity on computer image. We concluded that solid meal lag phase exist.

  15. Study on confirmation of Solid-Meal Lag Phase of Gastric Emptying

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Young; Lee, Kyoung Soo; Kim, Chang Guhn; Juhng, Seon Kwan; Won, Jong Jin; Nah, Yong Ho [Wonkwang University School of Medicine, Iksan (Korea, Republic of)

    1991-07-15

    The purpose of this study was to examine the existence of a lag phase of gastric emptying of solid meals. We studied solid phase gastric emptying in 26 normal subject using continuous data acquisition for 30 minutes. Each ingested a 300 g meal containing {sup 99m}Tc-labeled scrambled egg (solid 150 g, milk 150 ml). Lag phase was determined by 1) inspection of the gastric emptying curve 2) time to a 2% decrease in stomach activity 3) the time of visual appearance of duodenal activity on computer image. We concluded that solid meal lag phase exist.

  16. [*C]octanoic acid breath test to measure gastric emptying rate of solids.

    Science.gov (United States)

    Maes, B D; Ghoos, Y F; Rutgeerts, P J; Hiele, M I; Geypens, B; Vantrappen, G

    1994-12-01

    We have developed a breath test to measure solid gastric emptying using a standardized scrambled egg test meal (250 kcal) labeled with [14C]octanoic acid or [13C]octanoic acid. In vitro incubation studies showed that octanoic acid is a reliable marker of the solid phase. The breath test was validated in 36 subjects by simultaneous radioscintigraphic and breath test measurements. Nine healthy volunteers were studied after intravenous administration of 200 mg erythromycin and peroral administration of 30 mg propantheline, respectively. Erythromycin significantly enhanced gastric emptying, while propantheline significantly reduced gastric emptying rates. We conclude that the [*C]octanoic breath test is a promising and reliable test for measuring the gastric emptying rate of solids.

  17. Emptiness and Fullness

    DEFF Research Database (Denmark)

    Bregnbæk, Susanne; Bunkenborg, Mikkel

    As critical voices question the quality, authenticity, and value of people, goods, and words in post-Mao China, accusations of emptiness render things open to new investments of meaning, substance, and value. Exploring the production of lack and desire through fine-grained ethnography, this volume...... examines how diagnoses of emptiness operate in a range of very different domains in contemporary China: In the ostensibly meritocratic exam system and the rhetoric of officials, in underground churches, housing bubbles, and nationalist fantasies, in bodies possessed by spirits and evaluations of jade......, there is a pervasive concern with states of lack and emptiness and the contributions suggest that this play of emptiness and fullness is crucial to ongoing constructions of quality, value, and subjectivity in China....

  18. The relationship between gut hormone secretion and gastric emptying in different phases of the migrating motor complex

    DEFF Research Database (Denmark)

    Rasmussen, L; Oster-Jørgensen, E; Qvist, N

    1996-01-01

    a higher incremental integrated postprandial motilin response in phase I than in phase II (998 pmol/l*30 min (495 to 2010) versus 210 pmol/l*30 min (-270 to 2323), p total integrated motilin response and solid emptying at 120 min in phase I (Rs = 0.58; p......BACKGROUND: No studies are available on the relationship between the response of gut hormones and gastric emptying in different phases of the migrating motor complex. This study examined whether basal gut hormone concentrations in plasma before food ingestion are predictors of emptying...... total integrated area of cholecystokinin and solid emptying at 120 min was demonstrated (Rs = 0.62; p

  19. Gastric emptying, glucose metabolism and gut hormones: evaluation of a common preoperative carbohydrate beverage.

    Science.gov (United States)

    Vermeulen, Mechteld A R; Richir, Milan C; Garretsen, Martijn K; van Schie, Annelies; Ghatei, Mohammed A; Holst, Jens J; Heijboer, Annemieke C; Uitdehaag, Bernard M J; Diamant, Michaela; Eekhoff, E Marelise W; van Leeuwen, Paul A M; Ligthart-Melis, Gerdien C

    2011-09-01

    To study the gastric-emptying rate and gut hormonal response of two carbohydrate-rich beverages. A specifically designed carbohydrate-rich beverage is currently used to support the surgical patient metabolically. Fruit-based beverages may also promote recovery, due to natural antioxidant and carbohydrate content. However, gastric emptying of fluids is influenced by its nutrient composition; hence, safety of preoperative carbohydrate loading should be confirmed. Because gut hormones link carbohydrate metabolism and gastric emptying, hormonal responses were studied. In eight volunteers, gastric emptying rates of both 400 mL of a ready-to-use beverage (A: Nutricia preOp; 50.4 g carbohydrates-mainly polysaccharides; 260 mOsm/kg) and 400 mL over-the-counter fruit-based lemonade (B: Roosvicee Original; 48 g carbohydrates--mainly fruit-associated saccharides; 805 mOsm/kg) were determined scintigraphically (using hepatate Tc-99(m)) according to a crossover design. Plasma glucose, insulin, C-peptide, glucagon-like peptide (GLP-1), peptide YY, total glucagon, and ghrelin were studied. Gastric emptying showed no differences in residual volumes. Earlier onset in emptying for beverage A versus B was observed (trend), with significantly higher glucose, insulin, C-peptide, and glucagon responses at 15-90 min. GLP-1 was inversely related to residual volume. Fruit-based lemonade is a safe alternative for preoperative purposes. It induces a more limited glucose, insulin, and C-peptide response. Later onset in gastric emptying (B versus A: trend), lower glucagon release, and differences in beverage content and osmolarity may have contributed to those differences. Efficient emptying was reflected by early GLP-1 levels. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Gastric inhibitory polypeptide does not inhibit gastric emptying in humans

    DEFF Research Database (Denmark)

    Meier, Juris J; Goetze, Oliver; Anstipp, Jens

    2004-01-01

    ) = 0.15, P = 0.15 for intact GIP; r(2) = 0.21, P = 0.086 for total GIP). We conclude that gastric emptying does not appear to be influenced by GIP. The secretion of GIP after meal ingestion is not suppressed by its exogenous administration. The lack of effect of GIP on gastric emptying underlines......The insulinotropic gut hormone gastric inhibitory polypeptide (GIP) has been demonstrated to inhibit gastric acid secretion and was proposed to possess "enterogastrone" activity. GIP effects on gastric emptying have not yet been studied. Fifteen healthy male volunteers (23.9 +/- 3.3 yr, body mass....... Gastric emptying was calculated from the (13)CO(2) exhalation rates in breath samples collected over 360 min. Venous blood was drawn in 30-min intervals for the determination of glucose, insulin, C-peptide, and GIP (total and intact). Statistical calculations were made by use of repeated-measures ANOVA...

  1. Gastric emptying of solids: When should we sample

    International Nuclear Information System (INIS)

    Sfakianakis, G.; Spoliansky, G.; Cassady, J.; Barkin, J.; Serafini, A.

    1984-01-01

    Gastric emptying of solids has been studied for 20 normal volunteers using Tc-99m-sulfur-colloid labeled chicken liver or eggs. Residual gastric activity measured in 15 min intervals for 2 1/2 hrs was used to calculate gastric emptying. The procedure was proposed and is used to examine patients for suspected abnormal emptying. This approach however ties up one gamma camera and one technologist for a period of 2 1/2 - 3 hrs. Furthermore to classify any value more the 1SD below the mean as abnormal includes 16% of normals as abnormally low (false positives). In order to find the pattern of abnormalities and the best time to study patients we analyzed the results of 54 studies performed in patients with a variety of clinical problems. Gastric emptying was measured in 30 min intervals for 2 1/2 hrs after a standard meal of 2 scrambled eggs labeled with 1 mCi of Tc-99m-sulfur-colloid, 2 slices of bread and 300 ml of juice. To choose the point important to observe the authors studied the distribution of values at each time-point to determine when there is the greatest variability from the reported normal. When there is delayed emptying the 2 1/2 hr observation is the best discriminator and when there is accelerated emptying the 60 min observation is the best discriminator. In the group of patients the 150 min observation had no correlation with the age of the patients. It is possible that sampling at a later time could be more discriminatory. The authors propose sampling at 0, 60, and 150 min time as the most informative and cost effective approach to study the solid gastric emptying. The 2SD rather than 1SD below and above the mean should be used as the level to separate normal from abnormal results

  2. Gastric emptying of solids: When should we sample

    Energy Technology Data Exchange (ETDEWEB)

    Sfakianakis, G.; Spoliansky, G.; Cassady, J.; Barkin, J.; Serafini, A.

    1984-01-01

    Gastric emptying of solids has been studied for 20 normal volunteers using Tc-99m-sulfur-colloid labeled chicken liver or eggs. Residual gastric activity measured in 15 min intervals for 2 1/2 hrs was used to calculate gastric emptying. The procedure was proposed and is used to examine patients for suspected abnormal emptying. This approach however ties up one gamma camera and one technologist for a period of 2 1/2 - 3 hrs. Furthermore to classify any value more the 1SD below the mean as abnormal includes 16% of normals as abnormally low (false positives). In order to find the pattern of abnormalities and the best time to study patients we analyzed the results of 54 studies performed in patients with a variety of clinical problems. Gastric emptying was measured in 30 min intervals for 2 1/2 hrs after a standard meal of 2 scrambled eggs labeled with 1 mCi of Tc-99m-sulfur-colloid, 2 slices of bread and 300 ml of juice. To choose the point important to observe the authors studied the distribution of values at each time-point to determine when there is the greatest variability from the reported normal. When there is delayed emptying the 2 1/2 hr observation is the best discriminator and when there is accelerated emptying the 60 min observation is the best discriminator. In the group of patients the 150 min observation had no correlation with the age of the patients. It is possible that sampling at a later time could be more discriminatory. The authors propose sampling at 0, 60, and 150 min time as the most informative and cost effective approach to study the solid gastric emptying. The 2SD rather than 1SD below and above the mean should be used as the level to separate normal from abnormal results.

  3. The relationship between gut hormone secretion and gastric emptying in different phases of the migrating motor complex

    DEFF Research Database (Denmark)

    Rasmussen, L; Oster-Jørgensen, E; Qvist, N

    1996-01-01

    BACKGROUND: No studies are available on the relationship between the response of gut hormones and gastric emptying in different phases of the migrating motor complex. This study examined whether basal gut hormone concentrations in plasma before food ingestion are predictors of emptying characteri......BACKGROUND: No studies are available on the relationship between the response of gut hormones and gastric emptying in different phases of the migrating motor complex. This study examined whether basal gut hormone concentrations in plasma before food ingestion are predictors of emptying...... a higher incremental integrated postprandial motilin response in phase I than in phase II (998 pmol/l*30 min (495 to 2010) versus 210 pmol/l*30 min (-270 to 2323), p linear relationship between median total integrated motilin response and solid emptying at 120 min in phase I (Rs = 0.58; p...... linear relationship between total integrated area of cholecystokinin and solid emptying at 120 min was demonstrated (Rs = 0.62; p

  4. 30 CFR 75.1106-2 - Transportation of liquefied and nonliquefied compressed gas cylinders; requirements.

    Science.gov (United States)

    2010-07-01

    ... underground coal mine shall be: (1) Placed securely in devices designed to hold the cylinder in place during transit on self-propelled equipment or belt conveyors; (2) Disconnected from all hoses and gages; (3... containers which are specifically designed for holding such cylinders. (c) Liquefied and nonliquefied...

  5. Gastric and oesophageal emptying in obesity

    Energy Technology Data Exchange (ETDEWEB)

    Maddox, A.; Horowitz, M.; Wishart, J.; Collins, P. (Royal Adelaide Hospital (Australia))

    1989-01-01

    Gastric and esophageal emptying were evaluated in 31 obese patients and 31 control subjects. A double-isotope techniques was used to measure gastric emptying of a mixed solid/liquid meal, and esophageal emptying was measured as the time taken for a bolus of the solid meal to enter the stomach. Gastric emptying of the solid and the liquid meal and esophageal emptying were delayed in the obese patients compared with the control subjects. There were no significant relationships among gastric emptying, esophageal emptying, and upper gastrointestinal symptoms in the obese patients alone. However, in the total group of 62 subjects there were significant correlations between body mass index and both gastric and esophageal emptying. These results indicate that delayed gastric and esophageal emptying occurs frequently in obesity and that these abnormalties relate to body weight.

  6. Transient thermal stress problem for a circumferentially cracked hollow cylinder

    Science.gov (United States)

    Nied, H. F.; Erdogan, F.

    1982-01-01

    The transient thermal stress problem for a hollow elasticity cylinder containing an internal circumferential edge crack is considered. It is assumed that the problem is axisymmetric with regard to the crack geometry and the loading, and that the inertia effects are negligible. The problem is solved for a cylinder which is suddenly cooled from inside. First the transient temperature and stress distributions in an uncracked cylinder are calculated. By using the equal and opposite of this thermal stress as the crack surface traction in the isothermal cylinder the crack problem is then solved and the stress intensity factor is calculated. The numerical results are obtained as a function of the Fourier number tD/b(2) representing the time for various inner-to-outer radius ratios and relative crack depths, where D and b are respectively the coefficient of diffusivity and the outer radius of the cylinder.

  7. A simple labeled test meal for the evaluation of gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, Keita; Tanabe, Satoshi; Mitsuhashi, Toshiharu; Saigenji, Katsunori [Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Medicine

    1994-10-01

    We developed a simple test meal for the evaluation of gastric emptying. Preparation of a test meal for routine clinical use in institutions should be as simple as possible. The newly developed test meal consists of instant noodles labeled with 37 MBq (1 mCi) technetium-99m and does not require the use of cooking utensils. The test meal was given with drinking water (180 ml) to healthy adult volunteers (6 men, 34.5[+-]2.2 years old) and gastric emptying was measured at 0, 5, 10, 15, 30, 45, 60, 80, 100, 120 minutes after the end of the meal, and results were compared with those derived without drinking water. The emptying pattern of the test meal with water exhibited an exponential pattern typical of a liquid meal, and that without water formed a linear pattern after an initial lag phase in keeping with gastric emptying of a solid meal. In addition, the test meal was given to 11 patients of diabetic gastroparesis (5 men, 6 women, 50.4[+-]4.5 years old), and gastric emptying was measured. At each period evaluated, emptying was significantly slower in diabetic gastroparesis than in healthy controls (6 men, 1 woman, 32.1[+-]3.0 years old). These results show that the test meal is reliable and applicable to the clinical assessment of gastric emptying, while fulfilling the need for simplicity. (author).

  8. Gastric emptying in morbid obesity

    International Nuclear Information System (INIS)

    Venzina, W.; Chamberlain, M.; Carruthers, S.G.; Grace, D.M.; King, M.; Mowbray, R.D.; Bondy, D.C.

    1984-01-01

    Weight loss following gastroplasty had no correlation with gastric emptying rate. Patients who showed transient prolongation of gastric emptying returned to normal one year later and showed no significant difference in weight loss from those who did not have temporary delayed gastric emptying. Perhaps gatroplasty (at least temporarily) reduces the gastric volume producing early satiation without affecting the gastric emptying rate as tested by a small volume radiolabelled test meal. Longer follow-up is indicated to see if delayed weight gain occurs because of gastric pouch stretching and if this has any correlation with gastric emptying rate. (Author)

  9. Effect of size and density on canine gastric emptying of nondigestible solids

    International Nuclear Information System (INIS)

    Meyer, J.H.; Dressman, J.; Fink, A.; Amidon, G.

    1985-01-01

    Previous studies suggested that the food-containing canine stomach retains large, nondigestible spheres until all food has emptied; but it is not known whether there is a threshold size or a gradation of sizes that will empty along with food. Further, nothing is known of the effects of such parameters as density, shape, and surface energy on the emptying of nondigestible particles of any given size. To answer these questions 6 dogs with chronic duodenal fistulas were studied. Radiolabeled food and spheres were collected from the fistulas to compare the rate of gastric emptying of the spheres with that of the food. After a standard test meal of /sup 99m/Tc-labeled liver, steak, and water, diverted chyme was collected over a stack of sieves in 30-min fractions over 5 postcibal hours. The percent of fed spheres and fed /sup 99m/Tc-labeled liver in each collection was counted, and liquid chyme was returned to the distal duodenum. Spheres with a density of 1 emptied progressively faster as sphere diameters were decreased from 5 to 1 mm; but 0.015-mm spheres emptied at about the same rate as those with diameters of 1 mm. Emptying of the spheres became similar to emptying of the /sup 99m/Tc-labeled liver at about 1.6 mm. Spheres with densities less than 1 or greater than 1 emptied more slowly than spheres of the same size with a density of 1, whereas paper squares emptied the same way as spheres of comparable size and density. Surface energy did not affect emptying. The findings indicated that both sphere size and density affect their emptying in the presence of food

  10. Effect of mirtazapine on gastric emptying in patients with cancer-associated anorexia

    Directory of Open Access Journals (Sweden)

    N Kumar

    2017-01-01

    Full Text Available Background/Aims: The tetracyclic antidepressant mirtazapine is widely used in cancer patients suffering from anorexia. Although it is known to restore appetite, the exact mechanism remains unknown. The aim of the study was to evaluate if mirtazapine has any effect on gastric emptying in patients suffering from cancer-related anorexia. Materials and Methods: Solid-meal gastric-emptying study using radiolabeled meal was performed in 28 patients suffering from cancer anorexia once at baseline and repeated after 15 days of mirtazapine therapy. Results: At baseline, only 7 (25% patients had normal gastric motility (emptying >70% at 3 h postingestion whereas after treatment, 18 (64.2% patients achieved this limit. Mean % gastric emptying increased from 55.2% ±21.0% to 68.9% ±21.3% (P < 0.001. Mean gastric emptying time (t1/2 before intervention was 314.7 ± 421.0 min which decreased to 116.0 ± 106.7 min after intervention. Results were further analyzed by dividing the patients into two groups based on baseline gastric-emptying study. Group A (normal gastric emptying consisted of seven patients, mean % gastric emptying at baseline and postintervention was 75.0% ±5.25% and 87.57% ±5.94%, respectively (P < 0.018. Group B (delayed gastric emptying consisted of 21 patients, mean % gastric emptying at baseline and postintervention was 48.71% ±18.82% and 62.76% ±16.86%, respectively (P < 0.001. Conclusion: Mirtazapine significantly improves gastric emptying in patients of prostate and breast cancer suffering from cancer-associated anorexia.

  11. Steady particulate flows in a horizontal rotating cylinder

    Science.gov (United States)

    Yamane, K.; Nakagawa, M.; Altobelli, S. A.; Tanaka, T.; Tsuji, Y.

    1998-06-01

    Results of discrete element method (DEM) simulation and magnetic resonance imaging (MRI) experiments are compared for monodisperse granular materials flowing in a half-filled horizontal rotating cylinder. Because opacity is not a problem for MRI, a long cylinder with an aspect ratio ˜7 was used and the flow in a thin transverse slice near the center was studied. The particles were mustard seeds and the ratio of cylinder diameter to particle diameter was approximately 50. The parameters compared were dynamic angle of repose, velocity field in a plane perpendicular to the cylinder axis, and velocity fluctuations at rotation rates up to 30 rpm. The agreement between DEM and MRI was good when the friction coefficient and nonsphericity were adjusted in the simulation for the best fit.

  12. Empty Container Logistics

    Directory of Open Access Journals (Sweden)

    Jakov Karmelić

    2012-05-01

    Full Text Available Within the whole world container traffic, the largest share of containers is in the status of repositioning. Container repositioning results from the need for harmonization between the point of empty container accumulation and the point of demand, and waiting time for the availability of the first next transport of cargo. This status of containers on the container market is the consequence of imbalances in the worldwide trade distribution on most important shipping routes. The need for fast and effective reallocation of empty containers causes high costs and often represents an obstacle affecting the efficiency of port container terminals and inland carriers.In accordance with the above issue, this paper is mainly focused on the analysis of the data concerning global container capacities and the roots of container equipment imbalances, with the aim of determining the importance of empty container management and the need for empty container micro-logistic planning at the spread port area.

  13. Thermal convection of liquid sodium in inclined cylinders

    Science.gov (United States)

    Khalilov, Ruslan; Kolesnichenko, Ilya; Pavlinov, Alexander; Mamykin, Andrey; Shestakov, Alexander; Frick, Peter

    2018-04-01

    The effect of inclination on the low Prandtl number turbulent convection in a cylinder of unit aspect ratio was studied experimentally. The working fluid was sodium (Prandtl number Pr =0.0094 ), the measurements were performed for a fixed Rayleigh number Ra =(1.47 ±0.03 ) ×107 , and the inclination angle varied from β =0∘ (the Rayleigh-Bénard convection, the temperature gradient is vertical) up to β =90∘ (the applied temperature gradient is horizontal) with a step Δ β =10∘ . The effective axial heat flux characterized by the Nusselt number is minimal at β =0∘ and demonstrates a smooth growth with the increase of the cylinder inclination, reaching a maximum at angle β ≈70∘ and decreasing with a further increase of β . The maximal value of the normalized Nusselt number Nu (β )/Nu (0 ) was 1.21. In general, the dependence of Nu (β ) in a cylinder with unit aspect ratio is similar to what was observed in sodium convection in inclined long cylinders but is much weaker. The structure of the flow undergoes a significant transformation with inclination. Under moderate inclination (β ≲30∘ ), the fluctuations are strong and are provided by regular oscillations of large-scale circulation (LSC) and by turbulence. Under large inclination (β >60∘ ), the LSC is regular and the turbulence is weak, while in transient regimes (30∘border of transient and large inclinations. We find the first evidence of strong LSC fluctuations in low Prandtl number convective flow under moderate inclination. The rms azimuthal fluctuations of LSC, about 27∘ at β =0∘ , decrease almost linearly up to β =30∘ , where they are about 9∘. The angular fluctuations in the vicinity of the end faces are much stronger (about 37∘ at β =0∘ ) and weakly decrease up to β =20∘ . The strong anticorrelation of the fluctuations in two halves of the cylinder indicates the torsional character of LSC fluctuations. At β =30∘ , the intensity of the oscillations at the

  14. Gastric emptying abnormal in duodenal ulcer

    Energy Technology Data Exchange (ETDEWEB)

    Holt, S.; Heading, R.C.; Taylor, T.V.; Forrest, J.A.; Tothill, P.

    1986-07-01

    To investigate the possibility that an abnormality of gastric emptying exists in duodenal ulcer and to determine if such an abnormality persists after ulcer healing, scintigraphic gastric emptying measurements were undertaken in 16 duodenal ulcer patients before, during, and after therapy with cimetidine; in 12 patients with pernicious anemia, and in 12 control subjects. No difference was detected in the rate or pattern of gastric emptying in duodenal ulcer patients before and after ulcer healing with cimetidine compared with controls, but emptying of the solid component of the test meal was more rapid during treatment with the drug. Comparison of emptying patterns obtained in duodenal ulcer subjects during and after cimetidine treatment with those obtained in pernicious anemia patients and controls revealed a similar relationship that was characterized by a tendency for reduction in the normal differentiation between the emptying of solid and liquid from the stomach. The similarity in emptying patterns in these groups of subjects suggests that gastric emptying of solids may be influenced by changes in the volume of gastric secretion. The failure to detect an abnormality of gastric emptying in duodenal ulcer subjects before and after ulcer healing calls into question the widespread belief that abnormally rapid gastric emptying is a feature with pathogenetic significance in duodenal ulcer disease.

  15. Gastric emptying abnormal in duodenal ulcer

    International Nuclear Information System (INIS)

    Holt, S.; Heading, R.C.; Taylor, T.V.; Forrest, J.A.; Tothill, P.

    1986-01-01

    To investigate the possibility that an abnormality of gastric emptying exists in duodenal ulcer and to determine if such an abnormality persists after ulcer healing, scintigraphic gastric emptying measurements were undertaken in 16 duodenal ulcer patients before, during, and after therapy with cimetidine; in 12 patients with pernicious anemia, and in 12 control subjects. No difference was detected in the rate or pattern of gastric emptying in duodenal ulcer patients before and after ulcer healing with cimetidine compared with controls, but emptying of the solid component of the test meal was more rapid during treatment with the drug. Comparison of emptying patterns obtained in duodenal ulcer subjects during and after cimetidine treatment with those obtained in pernicious anemia patients and controls revealed a similar relationship that was characterized by a tendency for reduction in the normal differentiation between the emptying of solid and liquid from the stomach. The similarity in emptying patterns in these groups of subjects suggests that gastric emptying of solids may be influenced by changes in the volume of gastric secretion. The failure to detect an abnormality of gastric emptying in duodenal ulcer subjects before and after ulcer healing calls into question the widespread belief that abnormally rapid gastric emptying is a feature with pathogenetic significance in duodenal ulcer disease

  16. Gastric emptying and sieving of solid food and pancreatic and biliary secretions after solid meals in patients with nonresective ulcer surgery

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, E.A.; Thomson, J.B.; Jehn, D.; Reedy, T.; Elashoff, J.; Deveny, C.; Meyer, J.H.

    1984-12-01

    This study was undertaken to compare with previously published findings in normal subjects and subjects after truncal vagotomy and antrectomy the effects of nonresective ulcer surgery on (a) gastric emptying, grinding, and sieving of solid food and on (b) pancreatic and biliary secretions. Six subjects with proximal gastric vagotomy and 7 subjects with truncal vagotomy with pyloroplasty were studied using a previously validated indicator perfusion system with its aspiration port placed in the proximal jejunum. All subjects were given a meal of 30 g of /sup 99m/Tc-liver, 60 g of beefsteak, and 100 ml of H/sub 2/O. In conjunction with a gamma-camera to measure total gastric emptying of /sup 99m/Tc-liver, this method allowed the estimation of the fraction of 99mTc-liver emptied from the stomach as particles of less than 1-mm diameter; in addition, it was possible to measure jejunal concentrations and outputs of bile salts and pancreatic enzymes. In subjects with proximal gastric vagotomy, all parameters studied were indistinguishable from normal. Subjects with truncal vagotomy and pyloroplasty behaved similarly to subjects with vagotomy and antrectomy, showing (a) early precipitous emptying of food, (b) heterogeneous distribution of half-emptying times, (c) near normal concentration of biliary and pancreatic secretions, (d) markedly reduced jejunal flow rates, and (e) a reduction in postcibal trypsin secretion. In contrast to subjects after truncal vagotomy and antrectomy, however, the majority of subjects with vagotomy and pyloroplasty did not show a persistent defect in grinding and sieving of solid food.

  17. Electronic structure of the boron fullerene B14 and its silicon derivatives B13Si(+), B13Si(-) and B12Si2: a rationalization using a cylinder model.

    Science.gov (United States)

    Van Duong, Long; Nguyen, Minh Tho

    2016-06-29

    Geometric and electronic structures of the boron cluster B14 and its silicon derivatives B13Si(+), B13Si(-), and B12Si2 were determined using DFT calculations (TPSSh/6-311+G(d)). The B12Si2 fullerene, which is formed by substituting two B atoms at two apex positions of the B14 fullerene by two Si atoms, was also found as the global minimum structure. We demonstrated that the electronic structure and orbital configuration of these small fullerenes can be predicted by the wavefunctions of a particle on a cylinder. The early appearance of high angular node MOs in B14 and B12Si2 can be understood by this simple model. Replacement of one B atom at a top position of B14 by one Si atom, followed by the addition or removal of one electron does not lead to a global minimum fullerene structure for the anion B13Si(-) and cation B13Si(+). The early appearance of the 5σ1 orbital in B13Si(+) causes a lower stability for the fullerene-type structure.

  18. An update on corrosion monitoring in cylinder storage yards

    Energy Technology Data Exchange (ETDEWEB)

    Henson, H.M.; Newman, V.S.; Frazier, J.L. [Oak Ridge K-25 Site, TN (United States)

    1991-12-31

    Depleted uranium, from US uranium isotope enrichment activities, is stored in the form of solid uranium hexafluoride (UF{sub 6}) in A285 and A516 steel cylinders designed and manufactured to ASME Boiler and Pressure Vessel Code criteria. In general, storage facilities are open areas adjacent to the enrichment plants where the cylinders are exposed to weather. This paper describes the Oak Ridge program to determine the general corrosion behavior of UF{sub 6} cylinders, to determine cylinder yard conditions which are likely to affect long term storage of this material, and to assess cylinder storage yards against these criteria. This program is targeted at conditions specific to the Oak Ridge cylinder yards. Based on (a) determination of the current cylinder yard conditions, (b) determination of rusting behavior in regions of the cylinders showing accelerated attack, (c) monitoring of corrosion rates through periodic measurement of test coupons placed within the cylinder yards, and (d) establishment of a computer base to incorporate and retain these data, the technical division is working with the enrichment sites to implement an upgraded system for storage of this material until such time as it is used or converted.

  19. Analysis of an indirect neutron signature for enhanced UF_6 cylinder verification

    International Nuclear Information System (INIS)

    Kulisek, J.A.; McDonald, B.S.; Smith, L.E.; Zalavadia, M.A.; Webster, J.B.

    2017-01-01

    The International Atomic Energy Agency (IAEA) currently uses handheld gamma-ray spectrometers combined with ultrasonic wall-thickness gauges to verify the declared enrichment of uranium hexafluoride (UF_6) cylinders. The current method provides relatively low accuracy for the assay of "2"3"5U enrichment, especially for natural and depleted UF_6. Furthermore, the current method provides no capability to assay the absolute mass of "2"3"5U in the cylinder due to the localized instrument geometry and limited penetration of the 186-keV gamma-ray signature from "2"3"5U. Also, the current verification process is a time-consuming component of on-site inspections at uranium enrichment plants. Toward the goal of a more-capable cylinder assay method, the Pacific Northwest National Laboratory has developed the hybrid enrichment verification array (HEVA). HEVA measures both the traditional 186-keV direct signature and a non-traditional, high-energy neutron-induced signature (HEVA_N_T). HEVA_N_T enables full-volume assay of UF_6 cylinders by exploiting the relatively larger mean free paths of the neutrons emitted from the UF_6. In this work, Monte Carlo modeling is used as the basis for characterizing HEVA_N_T in terms of the individual contributions to HEVA_N_T from nuclides and hardware components. Monte Carlo modeling is also used to quantify the intrinsic efficiency of HEVA for neutron detection in a cylinder-assay geometry. Modeling predictions are validated against neutron-induced gamma-ray spectra from laboratory measurements and a relatively large population of Type 30B cylinders spanning a range of enrichments. Implications of the analysis and findings on the viability of HEVA for cylinder verification are discussed, such as the resistance of the HEVA_N_T signature to manipulation by the nearby placement of neutron-conversion materials.

  20. Effect of the GABA B agonist baclofen on dipyrone-induced delayed gastric emptying in rats

    Directory of Open Access Journals (Sweden)

    E.F. Collares

    2005-01-01

    Full Text Available Dipyrone administered intravenously (iv or intracerebroventricularly (icv delays gastric emptying (GE in rats. Gamma-aminobutyric acid (GABA is the most potent inhibitory neurotransmitter of the central nervous system. The objective of the present study was to determine the effect of icv baclofen, a GABA B receptor agonist, on delayed GE induced by dipyrone. Adult male Wistar rats received a saline test meal containing phenol red as a marker. GE was indirectly evaluated by determining the percent of gastric retention (%GR of the meal 10 min after orogastric administration. In the first experiment, the animals were injected iv with vehicle (Civ or 80 mg/kg (240 µmol/kg dipyrone (Dp iv, followed by icv injection of 10 µl vehicle (bac0, or 0.5 (bac0.5, 1 (bac1 or 2 µg (bac2 baclofen. In the second experiment, the animals were injected icv with 5 µl vehicle (Cicv or an equal volume of a solution containing 4 µmol (1333.2 µg dipyrone (Dp icv, followed by 5 µl vehicle (bac0 or 1 µg baclofen (bac1. GE was determined 10 min after icv injection. There was no significant difference between control animals from one experiment to another concerning GR values. Baclofen at the doses of 1 and 2 µg significantly reduced mean %GR induced by iv dipyrone (Dp iv bac1 = 35.9% and Dp iv bac2 = 26.9% vs Dp iv bac0 = 51.8%. Similarly, baclofen significantly reduced the effect of dipyrone injected icv (mean %GR: Dp icv bac1 = 30.4% vs Dp icv bac0 = 54.2%. The present results suggest that dipyrone induces delayed GE through a route in the central nervous system that is blocked by the activation of GABA B receptors.

  1. Numerical simulation coupling with experimental study on the non-uniform of each cylinder gas exchange and working processes of a multi-cylinder gasoline engine under transient conditions

    International Nuclear Information System (INIS)

    Zhou, Feng; Fu, Jianqin; Shu, Jun; Liu, Jingping; Wang, Shuqian; Feng, Renhua

    2016-01-01

    Highlights: • An approach is presented to detect the CTCV of engine under transient conditions. • The range and influence factors of CTCV of engine performances were revealed. • The maximum relative deviation of IMEP in each cylinder is larger than ±30%. • There appears a symmetry relation between CTCV of RGF and excess air coefficient. - Abstract: Cylinder-to-cylinder variation is unavoidable in multi-cylinder engine and has a severe impact on engine performance. To explore the cylinder-to-cylinder variation of engine under transient conditions, a hybrid method of dynamic signal measurement coupling with gas dynamics and thermodynamics processes simulation is presented to detect the parameters of engine. Then, this method is applied to an automobile engine under road test conditions, and the continuous state and performance parameters of each cylinder were obtained from cycle to cycle. On this basis, the range and influence factors of non-uniform of engine performance parameters were analyzed. The results show that, under transient conditions, the relative deviation of excess air coefficient in each cylinder is within ±5%, which is mainly affected by intake average pressure in low to medium speed operating regions but influenced by exhaust pressure wave and residual gas fraction in high-speed and high-load operating regions. There appears a symmetry relation between the non-uniform of RGF and excess air coefficient. The relative deviation of indicated mean effective pressure in each cylinder depends largely on the gas exchange performance, including excess air coefficient and residual gas fraction, and the maximum is larger than ±30%.

  2. Gastric emptying of solid radiopaque markers: studies in healthy subjects and diabetic patients

    International Nuclear Information System (INIS)

    Feldman, M.; Smith, H.J.; Simon, T.R.

    1984-01-01

    The purpose of these studies was to develop a radiologic method for assessing gastric emptying of an indigestible solid in humans and to apply this technique to the evaluation of patients with diabetes mellitus. Thirty healthy subjects ingested 10 solid radiopaque markers (small pieces of nasogastric tubing) together with a standard meal (donuts and 7-Up). Radiographs of the upper abdomen were obtained hourly for up to 6 h until all markers had emptied from the stomach. In some experiments, 99mTc-labeled scrambled eggs were added to the meal so that emptying of this digestible solid, assessed by scintigraphy, could be compared with emptying of liquids and solid radiopaque markers. In healthy subjects, the digestible solid emptied more slowly than the liquid (t 1/2 . 154 +/- 11 min vs. 30 +/- 3 min, p less than 0.001), but emptying of digestible solid was significantly faster than the emptying of the indigestible solid radiopaque markers. In diabetics, emptying rates for the digestible solid and liquid were close to normal (t 1/2 . 178 +/- 5 min and 40 +/- 3 min, respectively), whereas indigestible solid markers were retained in the stomach 6 h after the meal in 50% of the patients. Radiopaque markers proved to be a simple method for measuring gastric emptying of indigestible solids in humans. Using this technique, patients with insulin-dependent diabetes mellitus had a high incidence of abnormally slow gastric emptying of indigestible solids; the method may be a more sensitive indicator of gastric motor dysfunction than radionuclide scintigraphy

  3. Gastric emptying of solid radiopaque markers: studies in healthy subjects and diabetic patients

    Energy Technology Data Exchange (ETDEWEB)

    Feldman, M.; Smith, H.J.; Simon, T.R.

    1984-10-01

    The purpose of these studies was to develop a radiologic method for assessing gastric emptying of an indigestible solid in humans and to apply this technique to the evaluation of patients with diabetes mellitus. Thirty healthy subjects ingested 10 solid radiopaque markers (small pieces of nasogastric tubing) together with a standard meal (donuts and 7-Up). Radiographs of the upper abdomen were obtained hourly for up to 6 h until all markers had emptied from the stomach. In some experiments, 99mTc-labeled scrambled eggs were added to the meal so that emptying of this digestible solid, assessed by scintigraphy, could be compared with emptying of liquids and solid radiopaque markers. In healthy subjects, the digestible solid emptied more slowly than the liquid (t 1/2 . 154 +/- 11 min vs. 30 +/- 3 min, p less than 0.001), but emptying of digestible solid was significantly faster than the emptying of the indigestible solid radiopaque markers. In diabetics, emptying rates for the digestible solid and liquid were close to normal (t 1/2 . 178 +/- 5 min and 40 +/- 3 min, respectively), whereas indigestible solid markers were retained in the stomach 6 h after the meal in 50% of the patients. Radiopaque markers proved to be a simple method for measuring gastric emptying of indigestible solids in humans. Using this technique, patients with insulin-dependent diabetes mellitus had a high incidence of abnormally slow gastric emptying of indigestible solids; the method may be a more sensitive indicator of gastric motor dysfunction than radionuclide scintigraphy.

  4. Itopride for gastric volume, gastric emptying and drinking capacity in functional dyspepsia.

    Science.gov (United States)

    Abid, Shahab; Jafri, Wasim; Zaman, Maseeh Uz; Bilal, Rakhshanda; Awan, Safia; Abbas, Aamir

    2017-02-06

    To study the effect of itopride on gastric accommodation, gastric emptying and drinking capacity in functional dyspepsia (FD). Randomized controlled trial was conducted to check the effect of itopride on gastric accommodation, gastric emptying, capacity of tolerating nutrient liquid and symptoms of FD. We recruited a total of 31 patients having FD on the basis of ROME III criteria. After randomization, itopride was received by 15 patients while 16 patients received placebo. Gastric accommodation was determined using Gastric Scintigraphy. 13 C labeled octanoic breadth test was performed to assess gastric emptying. Capacity of tolerating nutrient liquid drink was checked using satiety drinking capacity test. The intervention group comprised of 150 mg itopride. Patients in both arms were followed for 4 wk. Mean age of the recruited participant 33 years (SD = 7.6) and most of the recruited individuals, i.e ., 21 (67.7%) were males. We found that there was no effect of itopride on gastric accommodation as measured at different in volumes in the itopride and control group with the empty stomach ( P = 0.14), at 20 min ( P = 0.38), 30 min ( P = 0.30), 40 min ( P = 0.43), 50 min ( P = 0.50), 60 min ( P = 0.81), 90 min ( P = 0.25) and 120 min ( P = 0.67). Gastric emptying done on a sub sample ( n = 11) showed no significant difference ( P = 0.58) between itopride and placebo group. There was no significant improvement in the capacity to tolerate liquid in the itopride group as compared to placebo ( P = 0.51). Similarly there was no significant improvement of symptoms as assessed through a composite symptom score ( P = 0.74). The change in QT interval in itopride group was not significantly different from placebo (0.10). Our study found no effect of itopride on gastric accommodation, gastric emptying and maximum tolerated volume in patients with FD.

  5. Flow around a cylinder surrounded by a permeable cylinder in shallow water

    Energy Technology Data Exchange (ETDEWEB)

    Ozkan, Gokturk M.; Akilli, Huseyin; Sahin, Besir [Cukurova University, Department of Mechanical Engineering, Faculty of Engineering and Architecture, Adana (Turkey); Oruc, Vedat [Dicle University, Department of Mechanical Engineering, Diyarbakir (Turkey)

    2012-12-15

    The change in flow characteristics downstream of a circular cylinder (inner cylinder) surrounded by an outer permeable cylinder was investigated in shallow water using particle image velocimetry technique. The diameter of the inner cylinder and the water height were kept constant during the experiments as d=50 mm and h{sub w}=25 mm, respectively. The depth-averaged free-stream velocity was also kept constant as U=170 mm/s which corresponded to a Reynolds number of Re{sub d}=8,500 based on the inner cylinder diameter. In order to examine the effect of diameter and porosity of the outer cylinder on flow characteristics of the inner cylinder, five different outer cylinder diameters (D=60, 70, 80, 90 and 100 mm) and four different porosities ({beta}=0.4, 0.5, 0.6 and 0.7) were used. It was shown that both porosity and outer cylinder diameter had a substantial effect on the flow characteristics downstream of the circular cylinder. Turbulent statistics clearly demonstrated that in comparison with the bare cylinder (natural case), turbulent kinetic energy and Reynolds stresses decreased remarkably when an outer cylinder was placed around the inner cylinder. Thereby, the interaction of shear layers of the inner cylinder has been successfully prevented by the presence of outer cylinder. It was suggested by referring to the results that the outer cylinder having 1.6{<=}D/d{<=}2.0 and 0.4{<=}D/d{<=}0.6 should be preferred to have a better flow control in the near wake since the peak magnitude of turbulent kinetic energy was considerably low in comparison with the natural case and it was nearly constant for these mentioned porosities {beta}, and outer cylinder to inner cylinder diameter ratios D/d. (orig.)

  6. Gastric emptying

    International Nuclear Information System (INIS)

    Bonaz, B.; Hostein, J.; Caravel, J.P.

    1990-01-01

    Gastric emptying (GE) of nutriments is a major function of the stomach. GE disorders are observed after gastric surgery and with various diseases, either of a strictly gastroenterologic kind or interesting other specialities (especially diabetes mellitus). Scintigraphy, which has allowed a better knowledge of GE physiological and pathological mechanisms, has now become the reference method for studying the emptying of solids and liquids. In a near future, it could well have two major applications: a diagnostic approach of functional digestive disorders and an assessment of the various effects of pharmacological drugs with digestive affinity [fr

  7. Gastric emptying of solid radiopaque markers: studies in healthy subjects and diabetic patients.

    Science.gov (United States)

    Feldman, M; Smith, H J; Simon, T R

    1984-10-01

    The purpose of these studies was to develop a radiologic method for assessing gastric emptying of an indigestible solid in humans and to apply this technique to the evaluation of patients with diabetes mellitus. Thirty healthy subjects ingested 10 solid radiopaque markers (small pieces of nasogastric tubing) together with a standard meal (donuts and 7-Up). Radiographs of the upper abdomen were obtained hourly for up to 6 h until all markers had emptied from the stomach. Although most of the liquid component of the meal, labeled with 111In, emptied during the first hour (as assessed simultaneously by radionuclide scintigraphy), few radiopaque markers emptied from the stomach during the first 2 h after the meal. Most markers emptied during the fourth postprandial hour, and all 10 markers had emptied by 6 h in 45 of 46 experiments. In contrast, not all of the solid radiopaque markers emptied from the stomach by 6 h in 16 of 26 experiments in patients with diabetes mellitus (p less than 0.001 vs. healthy controls). In some experiments, 99mTc-labeled scrambled eggs were added to the meal so that emptying of this digestible solid, assessed by scintigraphy, could be compared with emptying of liquids and solid radiopaque markers. In healthy subjects, the digestible solid emptied more slowly than the liquid (t 1/2 = 154 +/- 11 min vs. 30 +/- 3 min, p less than 0.001), but emptying of digestible solid was significantly faster than the emptying of the indigestible solid radiopaque markers. In diabetics, emptying rates for the digestible solid and liquid were close to normal (t 1/2 = 178 +/- 5 min and 40 +/- 3 min, respectively), whereas indigestible solid markers were retained in the stomach 6 h after the meal in 50% of the patients. Radiopaque markers proved to be a simple method for measuring gastric emptying of indigestible solids in humans. Using this technique, patients with insulin-dependent diabetes mellitus had a high incidence of abnormally slow gastric emptying of

  8. Next Generation Safeguards Initiative: Overview and Policy Context of UF6 Cylinder Tracking Program

    Energy Technology Data Exchange (ETDEWEB)

    Boyer, Brian D [Los Alamos National Laboratory; Whitaker, J. Michael [ORNL; White-Horton, Jessica L. [ORNL; Durbin, Karyn R. [NNSA

    2012-07-12

    Thousands of cylinders containing uranium hexafluoride (UF{sub 6}) move around the world from conversion plants to enrichment plants to fuel fabrication plants, and their contents could be very useful to a country intent on diverting uranium for clandestine use. Each of these large cylinders can contain close to a significant quantity of natural uranium (48Y cylinder) or low-enriched uranium (LEU) (30B cylinder) defined as 75 kg {sup 235}U which can be further clandestinely enriched to produce 1.5 to 2 significant quantities of high enriched uranium (HEU) within weeks or months depending on the scale of the clandestine facility. The National Nuclear Security Administration (NNSA) Next Generation Safeguards Initiative (NGSI) kicked off a 5-year plan in April 2011 to investigate the concept of a unique identification system for UF{sub 6} cylinders and potentially to develop a cylinder tracking system that could be used by facility operators and the International Atomic Energy Agency (IAEA). The goal is to design an integrated solution beneficial to both industry and inspectorates that would improve cylinder operations at the facilities and provide enhanced capabilities to deter and detect both diversion of low-enriched uranium and undeclared enriched uranium production. The 5-year plan consists of six separate incremental tasks: (1) define the problem and establish the requirements for a unique identification (UID) and monitoring system; (2) develop a concept of operations for the identification and monitoring system; (3) determine cylinder monitoring devices and technology; (4) develop a registry database to support proof-of-concept demonstration; (5) integrate that system for the demonstration; and (6) demonstrate proof-of-concept. Throughout NNSA's performance of the tasks outlined in this program, the multi-laboratory team emphasizes that extensive engagement with industry stakeholders, regulatory authorities and inspectorates is essential to its success.

  9. Velocity encoded cardiovascular magnetic resonance to assess left atrial appendage emptying

    Directory of Open Access Journals (Sweden)

    Muellerleile Kai

    2012-06-01

    Full Text Available Abstract Background The presence of impaired left atrial appendage (LAA function identifies patients who are prone to thrombus formation in the LAA and therefore being at high risk for subsequent cardioembolic stroke. LAA function is typically assessed by measurements of LAA emptying velocities using transesophageal echocardiography (TEE in clinical routine. This study aimed at evaluating the feasibility of assessing LAA emptying by velocity encoded (VENC cardiovascular magnetic resonance (CMR. Methods This study included 30 patients with sinus rhythm (n = 18 or atrial fibrillation (n = 12. VENC-CMR velocity measurements were performed perpendicular to the orifice of the LAA. Peak velocities were measured of passive diastolic LAA emptying (e-wave in all patients. Peak velocities of active, late-diastolic LAA emptying (a-wave were assessed in patients with sinus rhythm. Correlation and agreement was analyzed between VENC-CMR and TEE measurements of e- and a-wave peak velocities. Results A significant correlation and good agreement was found between VENC-CMR and TEE measurements of maximal e-wave velocities (r = 0.61, P  Conclusions The assessment of active and passive LAA emptying by VENC-CMR is feasible. Further evaluation is required of potential future clinical applications such as risk stratification for cardioembolic stroke.

  10. Analysis of an indirect neutron signature for enhanced UF{sub 6} cylinder verification

    Energy Technology Data Exchange (ETDEWEB)

    Kulisek, J.A., E-mail: Jonathan.Kulisek@pnnl.gov; McDonald, B.S.; Smith, L.E.; Zalavadia, M.A.; Webster, J.B.

    2017-02-21

    The International Atomic Energy Agency (IAEA) currently uses handheld gamma-ray spectrometers combined with ultrasonic wall-thickness gauges to verify the declared enrichment of uranium hexafluoride (UF{sub 6}) cylinders. The current method provides relatively low accuracy for the assay of {sup 235}U enrichment, especially for natural and depleted UF{sub 6}. Furthermore, the current method provides no capability to assay the absolute mass of {sup 235}U in the cylinder due to the localized instrument geometry and limited penetration of the 186-keV gamma-ray signature from {sup 235}U. Also, the current verification process is a time-consuming component of on-site inspections at uranium enrichment plants. Toward the goal of a more-capable cylinder assay method, the Pacific Northwest National Laboratory has developed the hybrid enrichment verification array (HEVA). HEVA measures both the traditional 186-keV direct signature and a non-traditional, high-energy neutron-induced signature (HEVA{sub NT}). HEVA{sub NT} enables full-volume assay of UF{sub 6} cylinders by exploiting the relatively larger mean free paths of the neutrons emitted from the UF{sub 6}. In this work, Monte Carlo modeling is used as the basis for characterizing HEVA{sub NT} in terms of the individual contributions to HEVA{sub NT} from nuclides and hardware components. Monte Carlo modeling is also used to quantify the intrinsic efficiency of HEVA for neutron detection in a cylinder-assay geometry. Modeling predictions are validated against neutron-induced gamma-ray spectra from laboratory measurements and a relatively large population of Type 30B cylinders spanning a range of enrichments. Implications of the analysis and findings on the viability of HEVA for cylinder verification are discussed, such as the resistance of the HEVA{sub NT} signature to manipulation by the nearby placement of neutron-conversion materials.

  11. Refurbishment and modification of existing protective shipping packages (for 30-inch UF{sub 6} cylinders) per USDOT specification No. USA-DOT-21PF-1A

    Energy Technology Data Exchange (ETDEWEB)

    Housholder, W.R. [Nuclear Containers, Incorporated, Elizabethton, TN (United States)

    1991-12-31

    This paper addresses the refurbishment procedures for existing shipping containers for 30-inch diameter UF{sub 6} cylinders in accordance with DOT Specification 21PF-1 and the criteria used to determine rejection when such packages are unsuitable for refurbishment.

  12. Yang-Mills fields due to an infinite charge cylinder

    International Nuclear Information System (INIS)

    Campbell, W.B.; Joseph, D.W.; Morgan, T.A.; Nebraska Univ., Lincoln

    1981-01-01

    The problem of determining time-independent solutions of the classical Yang-Mills equations for infinitely long charge cylinders is studied. A useful expression for the total energy in the field in terms of just the sources is derived. Numerical solutions have been found in the special cases of a small charge cylinder with a magnetic field B that either lies along the axis of symmetry or encircles the axis. It is as if these two solutions were due to currents encircling the axis or parallelling it, respectively. The condition that the solutions behave well at infinity implies an exponential fall off for the fields in the azimuthal B field case and a fall off more rapid than 1/R in the axial B field case, so that in both cases the existence of a B field requires the charge on the axis to be shieled. Consequently, these solutions do not behave at infinity at all like the Maxwell solution for a charge cylinder, and they have a lower energy per unit length. They show that in Yang-Mills theories the source does not determine a unique field. A classical interpretation of this is that the field remembers how the charges were transported during the construction of the cylinder. It also suggests that a quantum mechanical version of this problem would exhibit a spontaneous symmetry breaking to a less symmetric, lower energy vacuum. These solutions exhibit a twofold degeneracy, as the magnetic field may be either left- or right-handed in the azimuthal B field case, or point along the +z or -z axis in the axial B field case. (orig.)

  13. Effect of toxin-g from Tityus serrulatus scorpion venom on gastric emptying in rats

    Directory of Open Access Journals (Sweden)

    F. Bucaretchi

    1999-04-01

    Full Text Available The effect of toxin-g from Tityus serrulatus scorpion venom on the gastric emptying of liquids was studied in 176 young adult male Wistar rats (2-3 months of age divided into subgroups of 8 animals each. Toxin-g was injected iv at doses of 25, 37.5, 50 or 100 µg/kg and the effect on gastric emptying was assessed 30 min and 8 h later. A time-course study was also performed by injecting 50 µg of toxin-g /kg and measuring the effect on gastric emptying at times 0.25, 0.5, 1, 2, 4, 8, 24 and 48 h post-venom. Each envenomed animal was paired with its saline control and all received a saline test meal solution containing phenol red (60 µg/ml as a marker. Ten minutes after administering the test meal by gavage the animals were sacrificed and gastric retention was determined by measuring the residual marker concentration of the test meal. A significant delay in gastric emptying, at 30 min and 8 h post-venom, was observed only after 50 and 100 µg of toxin-g /kg compared to control values. The responses to these two doses were significantly different after 8 h post-venom. Toxin-g (50 µg/kg significantly delayed the gastric emptying of liquids at all times studied, with a peak response at 4 h after toxin administration compared to control values. These results indicate that the iv injection of toxin-g may induce a rapid, intense and sustained inhibition of gastric emptying 0.25 to 48 h after envenomation.

  14. Effect of metoclopramide on normal and delayed gastric emptying in gastroesophageal reflux patients

    Energy Technology Data Exchange (ETDEWEB)

    Fink, S.M.; Lange, R.C.; McCallum, R.W.

    1983-12-01

    Gastric emptying has an important role in the pathophysiology of gastroesophageal reflux disease. The effect of metoclopramide, a gastric prokinetic agent, in gastroesophageal reflux patients with normal as well as delayed emptying was investigated. Twenty-six patients with subjective and objective evidence of gastroesophageal reflux ingested an egg salad sandwich meal labeled with /sub 99m/technetium-DTPA for a baseline study, and then again on a separate day after receiving oral metoclopramide, 10 mg, 30 min prior to the test meal. The mean percent isotope remaining in the stomach after 90 min improved significantly from 70.3 +/- 3.9% (SEM) to 55.2 +/- 4.2% after metoclopramide. Fourteen (54%) had a basal emptying in the normal range of 34-69% retention of isotope at 90 min, (means +/- 2 SD), while it was slow in 12 (46%). For those with delayed basal gastric emptying, the mean retention of 88.9 +/- 2.9% at 90 min was significantly decreased by metoclopramide to 68.6 +/- 6.1%. In those patients with a normal basal gastric emptying and a mean retention of 54.4 +/- 2.3% at 90 min, there was also significant improvement (P less than 0.025) to 43.6 +/- 3.6% after metoclopramide. These data indicate that metoclopramide increased gastric emptying in gastroesophageal reflux patients with normal as well as delayed gastric emptying. Therefore on a patient management level a trial of metoclopramide is warranted in patients with gastroesophageal reflux disease and is not limited by the gastric emptying status of the patient.

  15. Effect of metoclopramide on normal and delayed gastric emptying in gastroesophageal reflux patients

    International Nuclear Information System (INIS)

    Fink, S.M.; Lange, R.C.; McCallum, R.W.

    1983-01-01

    Gastric emptying has an important role in the pathophysiology of gastroesophageal reflux disease. The effect of metoclopramide, a gastric prokinetic agent, in gastroesophageal reflux patients with normal as well as delayed emptying was investigated. Twenty-six patients with subjective and objective evidence of gastroesophageal reflux ingested an egg salad sandwich meal labeled with /sub 99m/technetium-DTPA for a baseline study, and then again on a separate day after receiving oral metoclopramide, 10 mg, 30 min prior to the test meal. The mean percent isotope remaining in the stomach after 90 min improved significantly from 70.3 +/- 3.9% (SEM) to 55.2 +/- 4.2% after metoclopramide. Fourteen (54%) had a basal emptying in the normal range of 34-69% retention of isotope at 90 min, (means +/- 2 SD), while it was slow in 12 (46%). For those with delayed basal gastric emptying, the mean retention of 88.9 +/- 2.9% at 90 min was significantly decreased by metoclopramide to 68.6 +/- 6.1%. In those patients with a normal basal gastric emptying and a mean retention of 54.4 +/- 2.3% at 90 min, there was also significant improvement (P less than 0.025) to 43.6 +/- 3.6% after metoclopramide. These data indicate that metoclopramide increased gastric emptying in gastroesophageal reflux patients with normal as well as delayed gastric emptying. Therefore on a patient management level a trial of metoclopramide is warranted in patients with gastroesophageal reflux disease and is not limited by the gastric emptying status of the patient

  16. Prediction of External Corrosion for Steel Cylinders--2004 Report

    International Nuclear Information System (INIS)

    Schmoyer, RLS

    2004-01-01

    Depleted uranium hexafluoride (UF 6 ) is stored in over 60,000 steel cylinders at the East Tennessee Technology Park (ETTP) in Oak Ridge, Tennessee, at the Paducah Gaseous Diffusion Plant (PGDP) in Paducah, Kentucky, and at the Portsmouth Gaseous Diffusion Plant (PORTS) in Portsmouth, Ohio. The cylinders range in age from 4 to 53 years. Although when new the cylinders had wall thicknesses specified to within manufacturing tolerances, over the years corrosion has reduced their actual wall thicknesses. The UF 6 Cylinder Project is managed by the United States Department of Energy (DOE) to safely maintain the UF 6 and the cylinders containing it. This report documents activities that address UF 6 Cylinder Project requirements and actions involving forecasting cylinder wall thicknesses. These requirements are delineated in the System Requirements Document (LMES 1997a), and the actions needed to fulfill them are specified in the System Engineering Management Plan (LMES 1997b). The report documents cylinder wall thickness projections based on models fit to ultrasonic thickness (UT) measurement data. UT data is collected at various locations on randomly sampled cylinders. For each cylinder sampled, the minimum UT measurement approximates the actual minimum thickness of the cylinder. Projections of numbers of cylinders expected to fail various thickness criteria are computed from corrosion models relating minimum wall thickness to cylinder age, initial thickness estimates, and cylinder subpopulations defined in terms of plant site, yard, top or bottom storage positions, nominal thickness, etc. In this report, UT data collected during FY03 is combined with UT data collected in earlier years (FY94-FY02), and all of the data is inventoried chronologically and by various subpopulations. The UT data is used to fit models of maximum pit depth and minimum thickness, and the fitted models are used to extrapolate minimum thickness estimates into the future and in turn to compute

  17. Extended Analytic Linear Model of Hydraulic Cylinder With Respect Different Piston Areas and Volumes

    Directory of Open Access Journals (Sweden)

    Petr KOŇAŘÍK

    2009-06-01

    Full Text Available Standard analytic linear model of hydraulic cylinder usually comes from assumptions of identical action piston areas on both sides of hydraulic cylinder (double piston rod and suitable operation point, which is usually chosen in the middle of piston. By reason of that volumes inside of cylinder are than same. Moreover for control of that arrangement of hydraulic cylinder, usually controlled by 4/3 servovalve, the same mount of flows comes in and comes out to each of chambers of hydraulic cylinder. Presented paper deal with development of extended form of analytic linear model of single piston rod hydraulic cylinder which respects different action piston areas and volumes inside of chambers of hydraulic cylinder and also two different input flows of hydraulic cylinder. In extended model are also considered possibilities of different dead volumes in hoses and intake parts of hydraulic cylinder. Dead volume has impact on damping of hydraulic cylinder. Because the system of hydraulic cylinder is generally presented as a integrative system with inertia of second order: eq , we can than obtain time constants and damping of hydraulic cylinder for each of analytic form model. The model has arisen for needs of model fractionation on two parts. Part of behaviour of chamber A and part of behaviour of chamber B of cylinder. It was created for the reason of analysis and synthesis of control parameters of regulation circuit of multivalve control concept of hydraulic drive with separately controlled chamber A and B which could be then used for.

  18. Prediction of External Corrosion for Steel Cylinders--2002 Report

    International Nuclear Information System (INIS)

    Schmoyer, RLS

    2002-01-01

    The United States Department of Energy (DOE) manages the UF 6 Cylinder Project. The project was formed to maintain and safely manage the depleted uranium hexafluoride (UF 6 ) stored in approximately 50,000 carbon steel cylinders. The cylinders are located at three DOE sites: the East Tennessee Technology Park (ETTP) site in Oak Ridge, Tennessee; the Paducah Gaseous Diffusion Plant (PGDP) in Paducah, Kentucky, and the Portsmouth Gaseous Diffusion Plant (PORTS) in Portsmouth, Ohio. The System Requirements Document (SRD) (LMES 1997a) delineates the requirements of the project, and the actions needed to fulfill these requirements are specified in the System Engineering Management Plan (SEMP) (LMES 1997b). This report documents activities that in whole or part satisfy specific requirements and actions stated in the UF 6 Cylinder Project SRD and SEMP with respect to forecasting cylinder conditions. The results presented here supercede those presented by Lyon (1995, 1996, 1997, 1998, 2000), and Schmoyer and Lyon (2001). Many of the wall thickness projections made in this report are conservative, because they are based on the assumption that corrosion trends will continue, despite activities such as improved monitoring, relocations to better storage, painting, and other improvements in storage conditions relative to the conditions at the times most of the wall thickness measurements were made. For thin-wall cylinders (design nominal wall thickness 312.5 mils), the critical minimum wall thicknesses criteria used in this report are 0 (breach), 62.5 mils, and 250 mils (1 mil = 0.001 in.). For thick-wall cylinders (design nominal wall thickness 625 mils), the thickness criteria used in this report are 0, 62.5 mils, and 500 mils. The criteria triples are preliminary boundaries identified within the project that indicate (1) loss of material (UF 6 ), (2) safe handling and stacking operations, and (3) standards for off-site transport and contents transfer criteria, respectively

  19. Gastric emptying of a solid meal

    International Nuclear Information System (INIS)

    Mannell, A.; Esser, J.D.

    1984-01-01

    A simple, non-invasive technique for measuring gastric emptying of a solid meal in clinical practice is described. Cooked chicken liver labelled with a radio-isotope is used. To establish the range of normal gastric emptying times 11 asymptomatic adults were studied. The effect of posture on solid emptying was also examined

  20. Gastric emptying of a solid meal

    Energy Technology Data Exchange (ETDEWEB)

    Mannell, A.; Esser, J.D. (University of the Witwatersrand, Johannesburg (South Africa))

    1984-09-08

    A simple, non-invasive technique for measuring gastric emptying of a solid meal in clinical practice is described. Cooked chicken liver labelled with a radio-isotope is used. To establish the range of normal gastric emptying times 11 asymptomatic adults were studied. The effect of posture on solid emptying was also examined.

  1. Experiments of flow-induced in-line oscillation of a circular cylinder in a water tunnel. 2. Influence of the aspect ratio of a cantilevered circular cylinder

    International Nuclear Information System (INIS)

    Nakamura, Akira; Okajima, Atsushi; Kosugi, Takashi

    2001-01-01

    The flow-induced in-line oscillation of a cantilevered circular cylinder was experimentally studied through free-oscillation tests in a water tunnel. The response displacement amplitude at a circular cylinder tip was measured at reduced velocity from 1.0 to 4.0. A cantilevered cylinder was supported by a plate spring mounted on the water tunnel wall. The cylinder aspect ratio was varied from 5 to 21 to investigate the effect of aspect ratio on the response displacement. It is found that cylinders with aspect ratios of 5 and 10 have one excitation region, while cylinders with aspect ratios of 14 and 21 have two excitation regions. The aspect ratio, therefore, affects the amplitude of the excitation regions. The influence of end-effect was also investigated using cylinders with an end plate attached to the free end. Since the cylinders with an end plate show two excitation regions, even at an aspect ratio of 5, the flow around the free end of a cantilevered cylinder causes the end-effect. The mechanism of vibration was investigated using a cylinder with a splitter plate in wake to prevent alternate vortices. The amplitude is greater than those of a normal cylinder without a splitter plate, especially at V r =2.3 to 3.0, where a cylinder with an end plate shows the second excitation region. In order words, the alternate vortices suppress the amplitude in this range. The maximum amplitude of each excitation region decreases in proportion to C n and the amplitude of the first excitation is more sensitive to C n . (author)

  2. Gastric emptying of liquids in rats dehydrated by water deprivation

    Directory of Open Access Journals (Sweden)

    Baracat E.C.E.

    1997-01-01

    Full Text Available The gastric emptying of liquids was investigated in male Wistar rats (8 to 10 weeks old, 210-300 g dehydrated by water deprivation. In this model of dehydration, weight loss, hematocrit and plasma density were significantly higher in the dehydrated animals than in the control groups after 48 and 72 h of water deprivation (P<0.05. Three test meals (saline (N = 10, water (N = 10 and a WHO rehydrating solution containing in one liter 90 mEq sodium, 20 mEq potassium, 80 mEq chloride and 30 mEq citrate (N = 10 were used to study gastric emptying following water deprivation for 24, 48 and 72 h. After 72 h, gastric emptying of the water (39.4% retention and rehydrating solution (49.2% retention test meals was significantly retarded compared to the corresponding control groups (P<0.05, Mann-Whitney test. The 72-h period of deprivation was used to study the recovery from dehydration, and water was supplied for 60 or 120 min after 67 h of deprivation. Body weight loss, hematocrit and plasma density tended to return to normal when water was offered for 120 min. In the animals supplied with water for 60 min, there was a recovery in the gastric emptying of water while the gastric emptying of the rehydrating solution was still retarded (53.1% retention; P<0.02, Kruskal-Wallis test. In the group supplied with water for 120 min, the gastric emptying of the rehydrating (51.7% retention and gluco-saline (46.0% retention solutions tended to be retarded (P = 0.04, Kruskal-Wallis test. In this model of dehydration caused by water deprivation, with little alteration in the body electrolyte content, gastric emptying of the rehydrating solution was retarded after rehydration with water. We conclude that the mechanisms whereby receptors in the duodenal mucosa can modify gastric motility are altered during dehydration caused by water deprivation

  3. Opioid-induced delay in gastric emptying: a peripheral mechanism in humans.

    LENUS (Irish Health Repository)

    Murphy, D B

    2012-02-03

    BACKGROUND: Opioids delay gastric emptying, which in turn may increase the risk of vomiting and pulmonary aspiration. Naloxone reverses this opiate action on gastric emptying, but it is not known whether this effect in humans is mediated by central or peripheral opiate antagonism. The importance of peripheral opioid receptor antagonism in modulating opioid-induced delay in gastric emptying was evaluated using methylnaltrexone, a quaternary derivative of the opiate antagonist naltrexone, which does not cross the blood-brain barrier. METHODS: In a randomized, double-blind, crossover placebo-controlled study, 11 healthy volunteers were given either placebo (saline), 0.09 mg\\/kg morphine, or 0.09 mg\\/kg morphine plus 0.3 mg\\/kg methylnaltrexone on three separate occasions before ingesting 500 ml deionized water. The rate of gastric emptying was measured by two methods: a noninvasive epigastric bioimpedance technique and the acetaminophen absorption test. RESULTS: The epigastric bioimpedance technique was sufficiently sensitive to detect opioid-induced changes in the rate of gastric emptying. The mean +\\/- SD time taken for the gastric volume to decrease to 50% (t0.5) after placebo was 5.5 +\\/- 2.1 min. Morphine prolonged gastric emptying to (t0.5) of 21 +\\/- 9.0 min (P < 0.03). Methylnaltrexone given concomitantly with morphine reversed the morphine-induced delay in gastric emptying to a t0.5 of 7.4 +\\/- 3.0 (P < 0.04). Maximum concentrations and area under the concentration curve from 0 to 90 min of serum acetaminophen concentrations after morphine were significantly different from placebo and morphine administered concomitantly with methylnaltrexone (P < 0.05). No difference in maximum concentration or area under the concentration curve from 0 to 90 min was noted between placebo and methylnaltrexone coadministered with morphine. CONCLUSIONS: The attenuation of morphine-induced delay in gastric emptying by methylnaltrexone suggests that the opioid effect is

  4. Bursting pressure of autofrettaged cylinders with inclined external cracks

    International Nuclear Information System (INIS)

    Seifi, Rahman; Babalhavaeji, Majid

    2012-01-01

    Autofrettaging a pressure vessel improves its pressure capacity. This is reliable if there isn’t any crack or other type of flaws. In this paper, the effects of external surface cracks on bursting pressure of autofrettaged cylinders are studied. It is observed that bursting pressure decreases considerably (up to 30%) due to external cracks in the cylinders without autofrettage. This reduction increases for high levels of the applied autofrettage. External axial cracks have more effects than inclined cracks. Comparing experimental and numerical results show that the numerical methods can acceptably predict the bursting pressure of the autofrettaged cracked cylinders. These predictions are valid when the fracture parameter (J-Integral) is calculated from the modified equation that takes into account the effects of residual stresses. - Highlights: ► Modified J-Integral can be used for study of autofrettaged cracked cylinders. ► External axial cracks reduce considerably the pressure capacity of cylinders. ► External circumferential cracks have not considerable effects on bursting pressure. ► Autofrettage has contrary effects on external crack in compared with internal crack.

  5. Involvement of endogenous opiates in regulation of gastric emptying of fat test meals in mice

    International Nuclear Information System (INIS)

    Fioramonti, J.; Fargeas, M.J.; Bueno, L.

    1988-01-01

    The role of endogenous opioids and cholecystokinin (CCK) in gastric emptying was investigated in mice killed 30 min after gavage with 51 Cr-radiolabeled liquid meals. The meals consisted of 0.5 ml of milk or one of five synthetic meals containing arabic gum, glucose and/or arachis oil and/or casein. Naloxone (0.1 mg/kg sc) significantly (P less than 0.01) accelerated gastric emptying of milk and meals containing fat but did not modify gastric emptying of nonfat meals. The CCK antagonist asperlicin (0.1 mg/kg ip) increased by 25% gastric emptying of milk. The gastric emptying of meals containing glucose and casein but not fat was reduced after administration of the COOH-terminal octapeptide of cholecystokinin (CCK-8, 4 micrograms/kg ip). This decrease was antagonized by both asperlicin (10 mg/kg ip) and naloxone (0.1 mg/kg sc). Intracerebroventricular (icv) administration of an opiate antagonist that poorly crosses the blood-brain barrier, methyl levallorphan (10 micrograms/kg), did not modify gastric emptying of milk but accelerated it when peripherally administered (0.1 mg/kg sc). Similarly, asperlicin (icv) administered at a dose of 1 mg/kg did not affect milk emptying. These results indicate that endogenous opiates are involved at peripheral levels in the regulation of gastric emptying of fat meals only and that such regulation involves release of CCK

  6. 46 CFR 58.30-15 - Pipe, tubing, valves, fittings, pumps, and motors.

    Science.gov (United States)

    2010-10-01

    ... hydraulic and pneumatic systems listed in § 58.30-1. (b) Materials used in the manufacture of tubing, pipes... 6, the wall thickness may be established on the basis of an applicable thick-wall cylinder equation...

  7. Study of influence of an experiment scale on cylinder test results

    Directory of Open Access Journals (Sweden)

    Waldemar A. Trzciński

    2014-03-01

    Full Text Available In the work, influence of a scale of experiment on the results of cylindrical test used todetermine the acceleration capabilities of explosives was analyzed. Explosives used in ammunition(TNT, hexogen and explosives for civil purpose (ammonals were selected for testing. Copper tubeswith different diameters and wall thickness were used. Conclusions are drawn regarding the advisabilityof increasing or decreasing the scale of the cylinder test.[b]Keywords[/b]: explosives, acceleration ability, cylinder test

  8. Prediction of external corrosion for steel cylinders

    International Nuclear Information System (INIS)

    Lyon, B.F.

    1997-02-01

    The US Department of Energy (DOE) currently manages the UF 6 Cylinder Program (the program). The program was formed to address the depleted-uranium hexafluoride (UF 6 ) stored in approximately 50,000 carbon steel cylinders. The cylinders are located at three DOE sites: the K-25 site (K-25) at Oak Ridge, Tennessee; the Paducah Gaseous Diffusion Plant (PGDP) in Paducah, Kentucky, and the Portsmouth Gaseous Diffusion Plant (PORTS) in Portsmouth, Ohio. The System Requirements Document (SRD) (LMES 1996a) delineates the requirements of the program. The appropriate actions needed to fulfill these requirements are then specified within the System Engineering Management Plan (SEMP) (LMES 1996b). The report presented herein documents activities that in whole or in part satisfy specific requirements and actions stated in the UF 6 Cylinder Program SRD and SEMP with respect to forecasting cylinder conditions. The wall thickness projections made in this report are based on the assumption that the corrosion trends noted will continue. Some activities planned may substantially reduce the rate of corrosion, in which case the results presented here are conservative. The results presented here are intended to supersede those presented previously, as the quality of several of the datasets has improved

  9. An Operator Perspective from a Facility Evaluation of an RFID-Based UF6 Cylinder Accounting and Tracking System

    International Nuclear Information System (INIS)

    Martyn, Rose; Fitzgerald, Peter; Stehle, Nicholas D.; Rowe, Nathan C.; Younkin, James R.

    2011-01-01

    An operational field test of a Radio-Frequency Identification (RFID) system for tracking and accounting UF6 cylinders was conducted at the Global Nuclear Fuel Americas (GNF) fuel fabrication plant in 2009. The Cylinder Accountability and Tracking System (CATS) was designed and deployed by Oak Ridge National Laboratory (ORNL) and evaluated in cooperation with GNF. The system required that passive RFID be attached to several UF6 30B cylinders as they were received at the site; then the cylinders were tracked as they proceeded to interim storage, to processing in an autoclave, and eventually to disposition from the site. This CATS deployment also provided a direct integration of scale data from the site accountability scales. The integration of this information into the tracking data provided an attribute for additional safeguards for evaluation. The field test provided insight into the advantages and challenges of using RFID at an operating nuclear facility. The RFID system allowed operators to interact with the technology and demonstrated the survivability of the tags and reader equipment in the process environment. This paper will provide the operator perspective on utilizing RFID technology for locating cylinders within the facility, thereby tracking the cylinders for process and for Material Control and Accounting functions. The paper also will present the operator viewpoint on RFID implemented as an independent safeguards system.

  10. Analysis of empty ATLAS pilot jobs

    Science.gov (United States)

    Love, P. A.; Alef, M.; Dal Pra, S.; Di Girolamo, A.; Forti, A.; Templon, J.; Vamvakopoulos, E.; ATLAS Collaboration

    2017-10-01

    In this analysis we quantify the wallclock time used by short empty pilot jobs on a number of WLCG compute resources. Pilot factory logs and site batch logs are used to provide independent accounts of the usage. Results show a wide variation of wallclock time used by short jobs depending on the site and queue, and changing with time. For a reference dataset of all jobs in August 2016, the fraction of wallclock time used by empty jobs per studied site ranged from 0.1% to 0.8%. Aside from the wall time used by empty pilots, we also looked at how many pilots were empty as a fraction of all pilots sent. Binning the August dataset into days, empty fractions between 2% and 90% were observed. The higher fractions correlate well with periods of few actual payloads being sent to the site.

  11. Mechanism-Based Modeling of Gastric Emptying Rate and Gallbladder Emptying in Response to Caloric Intake

    DEFF Research Database (Denmark)

    Guiastrennec, B; Sonne, David Peick; Hansen, M

    2016-01-01

    Bile acids released postprandially modify the rate and extent of absorption of lipophilic compounds. The present study aimed to predict gastric emptying (GE) rate and gallbladder emptying (GBE) patterns in response to caloric intake. A mechanism-based model for GE, cholecystokinin plasma concentr......Bile acids released postprandially modify the rate and extent of absorption of lipophilic compounds. The present study aimed to predict gastric emptying (GE) rate and gallbladder emptying (GBE) patterns in response to caloric intake. A mechanism-based model for GE, cholecystokinin plasma...... concentrations, and GBE was developed on data from 33 patients with type 2 diabetes and 33 matched nondiabetic individuals who were administered various test drinks. A feedback action of the caloric content entering the proximal small intestine was identified for the rate of GE. The cholecystokinin...

  12. Prediction of External Corrosion for Steel Cylinders--2004 Report

    Energy Technology Data Exchange (ETDEWEB)

    Schmoyer, RLS

    2004-07-07

    Depleted uranium hexafluoride (UF{sub 6}) is stored in over 60,000 steel cylinders at the East Tennessee Technology Park (ETTP) in Oak Ridge, Tennessee, at the Paducah Gaseous Diffusion Plant (PGDP) in Paducah, Kentucky, and at the Portsmouth Gaseous Diffusion Plant (PORTS) in Portsmouth, Ohio. The cylinders range in age from 4 to 53 years. Although when new the cylinders had wall thicknesses specified to within manufacturing tolerances, over the years corrosion has reduced their actual wall thicknesses. The UF{sub 6} Cylinder Project is managed by the United States Department of Energy (DOE) to safely maintain the UF{sub 6} and the cylinders containing it. This report documents activities that address UF{sub 6} Cylinder Project requirements and actions involving forecasting cylinder wall thicknesses. These requirements are delineated in the System Requirements Document (LMES 1997a), and the actions needed to fulfill them are specified in the System Engineering Management Plan (LMES 1997b). The report documents cylinder wall thickness projections based on models fit to ultrasonic thickness (UT) measurement data. UT data is collected at various locations on randomly sampled cylinders. For each cylinder sampled, the minimum UT measurement approximates the actual minimum thickness of the cylinder. Projections of numbers of cylinders expected to fail various thickness criteria are computed from corrosion models relating minimum wall thickness to cylinder age, initial thickness estimates, and cylinder subpopulations defined in terms of plant site, yard, top or bottom storage positions, nominal thickness, etc. In this report, UT data collected during FY03 is combined with UT data collected in earlier years (FY94-FY02), and all of the data is inventoried chronologically and by various subpopulations. The UT data is used to fit models of maximum pit depth and minimum thickness, and the fitted models are used to extrapolate minimum thickness estimates into the future and in

  13. Processing mixed-waste compressed-gas cylinders at the Oak Ridge Reservation

    International Nuclear Information System (INIS)

    Morris, M.I.; Conley, T.B.; Osborne-Lee, I.W.

    1998-05-01

    Until recently, several thousand kilograms of compressed gases were stored at the Oak Ridge Reservation (ORR), in Oak Ridge, Tennessee, because these cylinders could not be taken off-site in their state of configuration for disposal. Restrictions on the storage of old compressed-gas cylinders compelled the Waste Management Organization of Lockheed Martin Energy Systems, Inc. (LMES) to dispose of these materials. Furthermore, a milestone in the ORR Site Treatment Plan required repackaging and shipment off-site of 21 cylinders by September 30, 1997. A pilot project, coordinated by the Chemical Technology Division (CTD) at the Oak Ridge National Laboratory (ORNL), was undertaken to evaluate and recontainerize or neutralize these cylinders, which are mixed waste, to meet that milestone. Because the radiological component was considered to be confined to the exterior of the cylinder, the contents (once removed from the cylinder) could be handled as hazardous waste, and the cylinder could be handled as low-level waste (LLW). This pilot project to process 21 cylinders was important because of its potential impact. The successful completion of the project provides a newly demonstrated technology which can now be used to process the thousands of additional cylinders in inventory across the DOE complex. In this paper, many of the various aspects of implementing this project, including hurdles encountered and the lessons learned in overcoming them, are reported

  14. Effects of curcumin on the gastric emptying of albino rats.

    Science.gov (United States)

    Purwar, Brijesh; Shrivastava, Abha; Arora, Neetu; Kumar, Anil; Saxena, Yogesh

    2012-01-01

    Curcumin (diferuloylmethane), a polyphenol, is an active principle of the perennial herb Curcuma longa commonly known as turmeric. Turmeric (CURCUMA LONGA L.) is a medicinal plant extensively used in Ayurveda, Unani, and Siddha medicine as a home remedy for various diseases including biliary diseases, cough, hepatic diseases, wound healing. However studies on the effect of curcumin on the gastric emptying are nearly nonexistent. It is hypothesized that curcumin may have an effect on gastric emptying. For this reason the present study was aimed to study the effect of curcumin on gastric emptying. Rats were divided into 5 groups (Group I - Group V), based on the time interval between administration of curcumin/vehicular fluid to administration of barium sulphate (Group I - 1 hr, Group II - 8 hrs, Group III - 16 hrs, Group IV - 24 hrs, Group V - 48 hrs). Each group was further divided into two subgroups, Group A (control) and Group B (experimental), containing 6 rats each. Rats in experimental group were administered curcumin intragastrically, in the dose of 1 gm/kg body weight, suspended in normal saline (0.9% NaCl). The controls were given vehicular fluid intragastrically, in volume equal to the experimental animals. It was observed that there was a decrease in the gastric emptying in all the experimental groups.

  15. Processing of mixed-waste compressed-gas cylinders on the Oak Ridge Reservation

    International Nuclear Information System (INIS)

    Morris, M.I.; Conley, T.B.; Osborne-Lee, I.W.

    1998-03-01

    To comply with restrictions on the storage of old compressed gas cylinders, the environmental management organization of Lockheed Martin Energy Systems must dispose of several thousand kilograms of compressed gases stored on the Oak Ridge Reservation (ORR) because the cylinders cannot be taken off-site for disposal in their current configuration. In the ORR Site Treatment Plan, a milestone is cited that requires repackaging and shipment off-site of 21 cylinders by September 30, 1997. A project was undertaken to first evaluate and then either recontainerize or neutralize these cylinders using a transportable compressed gas recontainerization skid (TCGRS), which was developed by Integrated Environmental Services of Atlanta. The transportable system can: (1) sample, analyze, and identify at the site the chemical and radiological content of each cylinder, even those with inoperable valves; (2) breach cylinders, when necessary, to release their contents into a containment chamber; and (3) either neutralize the gas or liquid contents within the containment chamber or transfer the gas or liquids to a new cylinder. The old cylinders and cylinder fragments were disposed of and the gases neutralized or transferred to new cylinders for transportation off-site for disposal. The entire operation to process the 21 cylinders took place in only 5 days once the system was approved for operation. The system performed as expected and can now be used to process the potentially thousands of more cylinders located across the US Department of Energy (DOE) complex that have not yet been declared surplus

  16. Development of Advanced In-Cylinder Components and Tribological Systems for Low Heat Rejection Diesel Engines

    Science.gov (United States)

    Yonushonis, T. M.; Wiczynski, P. D.; Myers, M. R.; Anderson, D. D.; McDonald, A. C.; Weber, H. G.; Richardson, D. E.; Stafford, R. J.; Naylor, M. G.

    1999-01-01

    In-cylinder components and tribological system concepts were designed, fabricated and tested at conditions anticipated for a 55% thermal efficiency heavy duty diesel engine for the year 2000 and beyond. A Cummins L10 single cylinder research engine was used to evaluate a spherical joint piston and connecting rod with 19.3 MPa (2800 psi) peak cylinder pressure capability, a thermal fatigue resistant insulated cylinder head, radial combustion seal cylinder liners, a highly compliant steel top compression ring, a variable geometry turbocharger, and a microwave heated particulate trap. Components successfully demonstrated in the final test included spherical joint connecting rod with a fiber reinforced piston, high conformability steel top rings with wear resistant coatings, ceramic exhaust ports with strategic oil cooling and radial combustion seal cylinder liner with cooling jacket transfer fins. A Cummins 6B diesel was used to develop the analytical methods, materials, manufacturing technology and engine components for lighter weight diesel engines without sacrificing performance or durability. A 6B diesel engine was built and tested to calibrate analytical models for the aluminum cylinder head and aluminum block.

  17. Analysis of empty ATLAS pilot jobs

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00006364; The ATLAS collaboration; Dal Pra, S.; Di Girolamo, A.; Forti, A.; Templon, J.; Vamvakopoulos, E.

    2017-01-01

    In this analysis we quantify the wallclock time used by short empty pilot jobs on a number of WLCG compute resources. Pilot factory logs and site batch logs are used to provide independent accounts of the usage. Results show a wide variation of wallclock time used by short jobs depending on the site and queue, and changing with time. For a reference dataset of all jobs in August 2016, the fraction of wallclock time used by empty jobs per studied site ranged from 0.1% to 0.8%. The variation in wallclock usage may be explained by different workloads for each resource with a greater fraction when the workload is low. Aside from the wall time used by empty pilots, we also looked at how many pilots were empty as a fraction of all pilots sent. Binning the August dataset into days, empty fractions between 2% and 90% were observed.  The higher fractions correlate well with periods of few actual payloads being sent to the site.

  18. Engine Cylinder Temperature Control

    Science.gov (United States)

    Kilkenny, Jonathan Patrick; Duffy, Kevin Patrick

    2005-09-27

    A method and apparatus for controlling a temperature in a combustion cylinder in an internal combustion engine. The cylinder is fluidly connected to an intake manifold and an exhaust manifold. The method and apparatus includes increasing a back pressure associated with the exhaust manifold to a level sufficient to maintain a desired quantity of residual exhaust gas in the cylinder, and varying operation of an intake valve located between the intake manifold and the cylinder to an open duration sufficient to maintain a desired quantity of fresh air from the intake manifold to the cylinder, wherein controlling the quantities of residual exhaust gas and fresh air are performed to maintain the temperature in the cylinder at a desired level.

  19. Gastric emptying in patients with chronic liver diseases

    Energy Technology Data Exchange (ETDEWEB)

    Ishizu, Hirotaka; Shiomi, Susumu; Kawamura, Etsushi; Iwata, Yoshinori; Nishiguchi, Shuhei; Kawabe, Joji; Ochi, Hironobu [Osaka City Univ. (Japan). Graduate School of Medicine

    2002-05-01

    There have been a number of reports of gastric emptying in cirrhosis, all with unconfirmed results. Moreover, the mechanism for delayed emptying in cirrhotic patients in unclear. We evaluated gastric emptying in patients with chronic hepatitis and cirrhosis by means of gastric emptying scintigraphy. The subjects were 18 normal controls and 75 patients with chronic viral hepatitis (50 patients had chronic hepatitis and 25 patients had cirrhosis). Tc-99m diethyltriamine pentaacetic acid labeled solid meals were used to evaluate gastric emptying; the half-time (T 1/2) of which was calculated. Digestive symptom scores were determined at the time of gastric emptying tests. Fourteen (28%) of 50 patients with chronic hepatitis and 16 (64%) of 25 patients with cirrhosis had delayed gastric emptying. T 1/2 in patients with cirrhosis was significantly higher than that in normal controls and patients with chronic hepatitis (p=0.0001 and 0.0003, respectively). The difference between T 1/2 in patients with chronic hepatitis and that in normal controls was not significant. On regression analysis, two indices, the serum albumin level and platelet count, were found to be significantly related to delayed gastric emptying. Gastric emptying was more delayed in cirrhotic patients than in those with chronic hepatitis and normal controls. Delayed gastric emptying may be related to liver function and portal hypertension. (author)

  20. Bursting pressure of autofrettaged cylinders with inclined external cracks

    Energy Technology Data Exchange (ETDEWEB)

    Seifi, Rahman, E-mail: rseifi@basu.ac.ir [Mechanical Engineering Department, Faculty of Engineering, Bu-Ali Sina University, Hamedan (Iran, Islamic Republic of); Babalhavaeji, Majid [Mechanical Engineering Department, Faculty of Engineering, Bu-Ali Sina University, Hamedan (Iran, Islamic Republic of)

    2012-01-15

    Autofrettaging a pressure vessel improves its pressure capacity. This is reliable if there isn't any crack or other type of flaws. In this paper, the effects of external surface cracks on bursting pressure of autofrettaged cylinders are studied. It is observed that bursting pressure decreases considerably (up to 30%) due to external cracks in the cylinders without autofrettage. This reduction increases for high levels of the applied autofrettage. External axial cracks have more effects than inclined cracks. Comparing experimental and numerical results show that the numerical methods can acceptably predict the bursting pressure of the autofrettaged cracked cylinders. These predictions are valid when the fracture parameter (J-Integral) is calculated from the modified equation that takes into account the effects of residual stresses. - Highlights: Black-Right-Pointing-Pointer Modified J-Integral can be used for study of autofrettaged cracked cylinders. Black-Right-Pointing-Pointer External axial cracks reduce considerably the pressure capacity of cylinders. Black-Right-Pointing-Pointer External circumferential cracks have not considerable effects on bursting pressure. Black-Right-Pointing-Pointer Autofrettage has contrary effects on external crack in compared with internal crack.

  1. Optimized Dose Distribution of Gammamed Plus Vaginal Cylinders

    International Nuclear Information System (INIS)

    Supe, Sanjay S.; Bijina, T.K.; Varatharaj, C.; Shwetha, B.; Arunkumar, T.; Sathiyan, S.; Ganesh, K.M.; Ravikumar, M.

    2009-01-01

    Endometrial carcinoma is the most common malignancy arising in the female genital tract. Intracavitary vaginal cuff irradiation may be given alone or with external beam irradiation in patients determined to be at risk for locoregional recurrence. Vaginal cylinders are often used to deliver a brachytherapy dose to the vaginal apex and upper vagina or the entire vaginal surface in the management of postoperative endometrial cancer or cervical cancer. The dose distributions of HDR vaginal cylinders must be evaluated carefully, so that clinical experiences with LDR techniques can be used in guiding optimal use of HDR techniques. The aim of this study was to optimize dose distribution for Gammamed plus vaginal cylinders. Placement of dose optimization points was evaluated for its effect on optimized dose distributions. Two different dose optimization point models were used in this study, namely non-apex (dose optimization points only on periphery of cylinder) and apex (dose optimization points on periphery and along the curvature including the apex points). Thirteen dwell positions were used for the HDR dosimetry to obtain a 6-cm active length. Thus 13 optimization points were available at the periphery of the cylinder. The coordinates of the points along the curvature depended on the cylinder diameters and were chosen for each cylinder so that four points were distributed evenly in the curvature portion of the cylinder. Diameter of vaginal cylinders varied from 2.0 to 4.0 cm. Iterative optimization routine was utilized for all optimizations. The effects of various optimization routines (iterative, geometric, equal times) was studied for the 3.0-cm diameter vaginal cylinder. The effect of source travel step size on the optimized dose distributions for vaginal cylinders was also evaluated. All optimizations in this study were carried for dose of 6 Gy at dose optimization points. For both non-apex and apex models of vaginal cylinders, doses for apex point and three dome

  2. Assessment of Gastric Emptying in Patients with Autoimmune Gastritis.

    Science.gov (United States)

    Kalkan, Çağdaş; Soykan, Irfan; Soydal, Çiğdem; Özkan, Elgin; Kalkan, Emra

    2016-06-01

    Symptoms of patients with autoimmune gastritis are not specific, and some patients may present symptoms suggestive of delayed gastric emptying. This study aims to investigate whether any delay in gastric emptying of solid food exists in patients with autoimmune gastritis and, if so, to identify the factors that might affect delayed gastric emptying. A total of 165 patients (106 women) diagnosed as having autoimmune gastritis were analyzed by means of a gastric emptying test. All patients underwent a standardized scintigraphic gastric emptying study. Patients with delayed gastric emptying and normal gastric emptying tests were then compared by means of factors that might affect gastric emptying. Also 65 patients with functional dyspepsia who had a gastric emptying study constituted the control group. The median gastric emptying T ½ time was 127.43 min (min-max 50-953) for patients with AIG and 81 min (min-max 21-121.6) for functional dyspepsia patients (p gastritis, gastric emptying is generally delayed. Autoimmune gastritis is an important etiology to explain the finding of delayed gastric emptying on a radionuclide test. This new finding is likely to be relevant to clinicians when evaluating and initiating appropriate medical treatment for patients with autoimmune gastritis manifesting upper gastrointestinal symptoms.

  3. Delamination of Composite Cylinders

    Science.gov (United States)

    Davies, Peter; Carlsson, Leif A.

    The delamination resistance of filament wound glass/epoxy cylinders has been characterized for a range of winding angles and fracture mode ratios using beam fracture specimens. The results reveal that the delamination fracture resistance increases with increasing winding angle and mode II (shear) fraction (GΠ/G). It was also found that interlaced fiber bundles in the filament wound cylinder wall acted as effective crack arresters in mode I loading. To examine the sensitivity of delamina-tion damage on the strength of the cylinders, external pressure tests were performed on filament-wound glass/epoxy composite cylinders with artificial defects and impact damage. The results revealed that the cylinder strength was insensitive to the presence of single delaminations but impact damage caused reductions in failure pressure. The insensitivity of the failure pressure to a single delamination is attributed to the absence of buckling of the delaminated sublaminates before the cylinder wall collapsed. The impacted cylinders contained multiple delaminations, which caused local reduction in the compressive load capability and reduction in failure pressure. The response of glass/epoxy cylinders was compared to impacted carbon reinforced cylinders. Carbon/epoxy is more sensitive to damage but retains higher implosion resistance while carbon/PEEK shows the opposite trend.

  4. Effect of oral administration of Terminalia chebula on gastric emptying: an experimental study.

    Directory of Open Access Journals (Sweden)

    Tamhane M

    1997-01-01

    Full Text Available Terminalia chebula is a commonly advocated agent in Ayurveda for improving gastrointestinal motility. Charles Foster rats (150-200 gms of either sex were divided into four groups as follows--Group 1 (n = 15 normal animals; Group II (n = 6 rats administered metoclopramide (1.35 mg/kg; Group III (n = 8 rats given atropine (0.45 mg/kg. These agents were injected intramuscularly, 30 mins before the experiment. Rats from Group IV (n = 8 were administered Terminalia chebula (100 mg/kg/day for 15 days orally. Metoclopramide and atropine have established prokinetic and antikinetic activities respectively and are therefore included for comparison. All rats were then given a test meal of methyl cellulose (1.5% mixed with phenol red (50 mg/100 ml orally and gastric emptying was measured 20 mins later. Gastric emptying of normal rats (Group I was found to be 51.6 +/- 7.79%. Metoclopramide significantly increased the gastric emptying (76.33 +/- 12.37%; p < 0.01 and atropine inhibited the motility (% gastric emptying being 7.26 +/- 19.76%; p < 0.01. Terminalia chebula was found to increase the percent gastric emptying (86.57 +/- 6.65%; p < 0.01. Thus from this study it appears that Terminalia chebula can serve as an useful alternative to prokinetic drugs available today.

  5. Numerical investigation on flow-induced vibration of a triangular cylinder at a low Reynolds number

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Huakun; Zhao, Dongliang; Yang, Wenyu; Yu, Guoliang, E-mail: yugl@sjtu.edu.cn [State Key Laboratory of Ocean Engineering, School of Naval Architecture, Ocean and Civil Engineering, Shanghai Jiao Tong University, Shanghai, People’s Republic of China (China)

    2015-02-01

    Flow-induced vibration (FIV) of a triangular cylinder is numerically investigated at a Reynolds number of Re = 100. The four-step fractional finite element method is employed to solve the two-dimensional (2D) incompressible Navier–Stokes equations. The cylinder is endowed with a two-degree-of-freedom motion with the reduced mass ratio of M{sub r} = 2. Three typical flow incidence angles, α = 0°, 30° and 60°, are examined to identify the effect of incidence angle on the vibration characteristics of the cylinder. For each α, computations are conducted in a wide range of reduced velocities 2 U{sub r} ≤ 18. The numerical results show that at α = 0° and 30°, the responses of the cylinder are dominated by vortex-induced vibration which resembles that of a circular cylinder. At α = 0°, the peak amplitude of transverse vibration is the smallest among the three investigated α, and most of the cylinder motions exhibit a regular figure-eight trajectory. Some single-loop trajectories are observed at α = 30°, where the vibration frequency in the in-line direction is always identical to that in the transverse direction. At α = 60°, the triangular cylinder undergoes a typical transverse galloping with large amplitude and low frequency, and the vibration trajectories appear to be regular or irregular figure-eight patterns, which are strongly affected by the reduced velocity. (paper)

  6. Recent advances in gastric emptying scintigraphy

    International Nuclear Information System (INIS)

    Urbain, J.L.C.; Mayeur, S.M.

    1996-01-01

    Gastric emptying scintigraphy was introduced more than 25 years ago by Grittith and still remains the gold standard to assess gastric emptying. Test meals, radiopharmaceuticals and acquisition procedures have been refined and optimized over the years and the test procedure is now pretty well standardized. However, in its most common use, gastric emptying scintigraphy provides little information on gastric physiology. Over the last decade, modelling of the liquid and solid emptying curves have brought some insight in the complex gastric physiology. Compartmental analysis of the stomach has also provided information on the pathophysiological mechanisms of delayed gastric emptying. Over the past 5 years, the most dramatic development in gastric emptying scintigraphy has been the introduction of Digital Antral Scintigraphy (DAS). Digital Antral scintigraphy basically consists in dynamically imaging of the stomach and the use of a refined Fourier transform processing method. This new procedure allows for the visualization of antral contractions and, alike manometry, permits quantitative characterization on the frequency and amplitude of these contractions. Overall, this new procedure provides a unique, non invasive tool to characterize gastric motility, to define the pathophysiologic mechanisms of gastric motor disorders and to evaluate the effect of new gastro-kinetic compounds. (authors). 241 refs., 5 figs

  7. Internal combustion engine cylinder-to-cylinder balancing with balanced air-fuel ratios

    Science.gov (United States)

    Harris, Ralph E.; Bourn, Gary D.; Smalley, Anthony J.

    2006-01-03

    A method of balancing combustion among cylinders of an internal combustion engine. For each cylinder, a normalized peak firing pressure is calculated as the ratio of its peak firing pressure to its combustion pressure. Each cylinder's normalized peak firing pressure is compared to a target value for normalized peak firing pressure. The fuel flow is adjusted to any cylinder whose normalized peak firing pressure is not substantially equal to the target value.

  8. Preliminary Concept of Operations for a Global Cylinder Identification and Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Whitaker, J. M. [ORNL; White-Horton, J. L. [ORNL; Morgan, J. B. [InSolves Associates

    2013-08-01

    This report describes a preliminary concept of operations for a Global Cylinder Identification and Monitoring System that could improve the efficiency of the International Atomic Energy Agency (IAEA) in conducting its current inspection activities and could provide a capability to substantially increase its ability to detect credible diversion scenarios and undeclared production pathways involving UF6 cylinders. There exist concerns that a proliferant State with access to enrichment technology could obtain a cylinder containing natural or low-enriched uranium hexafluoride (UF6) and produce a significant quantity (SQ)1 of highly enriched uranium in as little as 30 days. The National Nuclear Security Administration (NNSA) through the Next Generation Safeguards Initiative sponsored a multi-laboratory team to develop an integrated system that provides for detecting scenarios involving 1) diverting an entire declared cylinder for enrichment at a clandestine facility, 2) misusing a declared cylinder at a safeguarded facility, and 3) using an undeclared cylinder at a safeguarded facility. An important objective in developing this integrated system was to improve the timeliness for detecting the cylinder diversion and undeclared production scenarios. Developing this preliminary concept required in-depth analyses of current operational and safeguards practices at conversion, enrichment, and fuel fabrication facilities. The analyses evaluated the processing, movement, and storage of cylinders at the facilities; the movement of cylinders between facilities (including cylinder fabrication); and the misuse of safeguarded facilities.

  9. Empty seeds are not always bad: simultaneous effect of seed emptiness and masting on animal seed predation.

    Directory of Open Access Journals (Sweden)

    Ramón Perea

    Full Text Available Seed masting and production of empty seeds have often been considered independently as different strategies to reduce seed predation by animals. Here, we integrate both phenomena within the whole assemblage of seed predators (both pre and post-dispersal and in two contrasting microsites (open vs. sheltered to improve our understanding of the factors controlling seed predation in a wind-dispersed tree (Ulmus laevis. In years with larger crop sizes more avian seed predators were attracted with an increase in the proportion of full seeds predated on the ground. However, for abundant crops, the presence of empty seeds decreased the proportion of full seeds predated. Empty seeds remained for a very long period in the tree, making location of full seeds more difficult for pre-dispersal predators and expanding the overall seed drop period at a very low cost (in dry biomass and allocation of C, N and P. Parthenocarpy (non-fertilized seeds was the main cause of seed emptiness whereas seed abortion was produced in low quantity. These aborted seeds fell prematurely and, thus, could not work as deceptive seeds. A proportion of 50% empty seeds significantly reduced ground seed predation by 26%. However, a high rate of parthenocarpy (beyond 50% empty seeds did not significantly reduce seed predation in comparison to 50% empty seeds. We also found a high variability and unpredictability in the production of empty seeds, both at tree and population level, making predator deception more effective. Open areas were especially important to facilitate seed survival since rodents (the main post-dispersal predators consumed seeds mostly under shrub cover. In elm trees parthenocarpy is a common event that might work as an adaptive strategy to reduce seed predation. Masting per se did not apparently reduce the overall proportion of seeds predated in this wind-dispersed tree, but kept great numbers of seeds unconsumed.

  10. Testing and evaluation of used UF6 shipping packages

    International Nuclear Information System (INIS)

    Barlow, C.R.; Ziehlke, K.T.; Pryor, W.A.; Housholder, W.R.

    1986-01-01

    Damage to shipping packages and their components, whether due to normal environmental exposure or because of unforeseen accidents, requires occasional reevaluation and requalification to assure the suitability of the packages for continued service. Pressure tests have been conducted on used 30B cylinders that were involved in a warehouse fire to assess the possible damaging effects of the exposure. Deteriorated and mechanically damaged overpacks which had absorbed large quantities of water in service were subjected to drying tests, foam properties were evaluated, and a rehabilitation procedure was developed to allow return of such packages to service. Protective shipping packages show deterioration with extended service, principally structural damage from rough handling and rust damage from exposure to weather and from storage practices which may promote absorption of water by the insulating foam. The structural and thermal properties of the phenolic foam insulation from used shipping packages were found to be not adversely affected by absorbed water, and they were not degraded by the drying process. In order to slow or avoid continuing rust damage in renovated packages, however, a process was developed for drying the foam in commercial facilities prior to restoration work on used or damaged containers. Two 2-1/2-ton steel transport cylinders, type 30B, were involved in a warehouse fire where portions of the cylinders were estimated to have reached a temperature of 1600 0 F. The cylinders were empty at the time of the fire and thus were not in the protective packages in which full product cylinders are handled while in transit. Hydrostatic burst tests showed that the integrity of the cylinders was not degraded by the fire exposure. They withstood test pressures in excess of 10 times the design pressure, and showed a volume expansion of 30% above the original capacity before rupturing in a completely ductile fashion

  11. 235U enrichment determination on UF6 cylinders with CZT detectors

    Science.gov (United States)

    Berndt, Reinhard; Mortreau, Patricia

    2018-04-01

    Measurements of uranium enrichment in UF6 transit cylinders are an important nuclear safeguards verification task, which is performed using a non-destructive assay method, the traditional enrichment meter, which involves measuring the count rate of the 186 keV gamma ray. This provides a direct measure of the 235U enrichment. Measurements are typically performed using either high-resolution detectors (Germanium) with e-cooling and battery operation, or portable devices equipped with low resolution detectors (NaI). Despite good results being achieved when measuring Low Enriched Uranium in 30B type cylinders and natural uranium in 48Y type containers using both detector systems, there are situations, which preclude the use of one or both of these systems. The focus of this work is to address some of the recognized limitations in relation to the current use of the above detector systems by considering the feasibility of an inspection instrument for 235U enrichment measurements on UF6 cylinders using the compact and light Cadmium Zinc Telluride (CZT) detectors. In the present work, test measurements were carried out, under field conditions and on full-size objects, with different CZT detectors, in particular for situations where existing systems cannot be used e.g. for stacks of 48Y type containers with depleted uranium. The main result of this study shows that the CZT detectors, actually a cluster of four μCZT1500 micro spectrometers provide as good results as the germanium detector in the ORTEC Micro-trans SPEC HPGe Portable spectrometer, and most importantly in particular for natural and depleted uranium in 48Y cylinders.

  12. SU-G-206-06: Analytic Dose Function for CT Scans in Infinite Cylinders as a Function of Scan Length and Cylinder Radius

    Energy Technology Data Exchange (ETDEWEB)

    Bakalyar, D [Henry Ford Health System, Detroit, MI (United States); Feng, W [New York Presbyterian Hospital, Tenafly, NJ (United States); McKenney, S [Children’s National Medical Center, Washington, DC (United States)

    2016-06-15

    Purpose: The radiation dose absorbed at a particular radius ρ within the central plane of a long cylinder following a CT scan is a function of the length of the scan L and the cylinder radius R along with kVp and cylinder composition. An analytic function was created that that not only expresses these dependencies but is integrable in closed form over the area of the central plane. This feature facilitates explicit calculation of the planar average dose. The “approach to equilibrium” h(L) discussed in the TG111 report is seamlessly included in this function. Methods: For a cylindrically symmetric radiation field, Monte Carlo calculations were performed to compute the dose distribution to long polyethylene cylinders for scans of varying L for cylinders ranging in radius from 5 to 20 cm. The function was developed from the resultant Monte Carlo data. In addition, the function was successfully fit to data taken from measurements on the 30 cm diameter ICRU/TG200 phantom using a real-time dosimeter. Results: Symmetry and continuity dictate a local extremum at the center which is a minimum for the larger sizes. There are competing effects as the beam penetrates the cylinder from the outside: attenuation, resulting in a decrease; scatter, abruptly increasing at the circumference. This competition may result in an absolute maximum between the center and outer edge leading to a “gull wing” shape for the radial dependence. For the smallest cylinders, scatter may dominate to the extent that there is an absolute maximum at the center. Conclusion: An integrable, analytic function has been developed that provides the radial dependency of dose for the central plane of a scan of length L for cylinders of varying diameter. Equivalently, we have developed h(L,R,ρ).

  13. Gastric emptying in chronic dyspepsia

    International Nuclear Information System (INIS)

    Sielaff, F.; Jahnel, P.; Sest, C.; Sydow, K.; Sapia, C.; Hass, A.; Buchali, K.

    1987-01-01

    Gastric emptying of a semiliquid test meal with 5 MBq /sup 99m/Tc-sulfur colloid as a marker was measured in 97 chronic dyspeptic patients and 16 healthy subjects. A comparison of half emptying time between both showed that chronic dyspeptic patients empty semiliquid meal at a significantly (p < 0.005) slower rate (at 70 +- 33 min) than healthy controls (at 52 x 20 min). The studies indicate that gastric stasis in chronic dyspepsia is not caused by inflammatory changes in gastric or duodenal mucosa nor by different gastric acid secretion. The presence of stasis cannot be predicted sufficiently by anamnestic complaints or endoscopic findings. (author)

  14. Scintigraphic study of gastric emptying with colloidal tin

    International Nuclear Information System (INIS)

    Rodríguez Paleo, Lester; Nuez Vilar, Maricela; Machado Lois, Marisel; López González, María Karla; Torres Leyva, Oscar; Izquierdo Izquierdo, Yimel; García González, Idelsy; Conesa Gonzalez, Ana Ibis

    2016-01-01

    Gastroparesis is defined as a delay in gastric emptying in the absence of mechanical obstruction, associated with symptoms such as nausea and / or vomiting, feeling of postprandial gastric fullness, early satiety or epigastric pain for more than 3 months. The gold standard in the diagnosis of delayed gastric emptying scintigraphy is gastric emptying and radiopharmaceutical has been used more 99m Tc-sulfur colloid not available in the country. In order to evaluate the usefulness of colloidal tin in the scintigraphic gastric emptying study, a descriptive study was conducted in 64 patients over 18 years using as radiopharmaceutical 99m Tc-Sn colloid. 31% of patients had symptoms. The emptying time was normal in 50 cases and the association of gastroparesis symptoms was observed in 20 (15 diabetic and 5 non-diabetic), 9 patients had a delayed emptying, but reported no symptoms. Gastroparesis was more frequent in women than in men (35% versus 21%). 21% of patients had a moderate delayed gastric emptying. Conclusions: The results obtained with 99m Tc-Sn colloid are comparable to those reported by other authors using 99m Tc-SC in the scintigraphic assessment of gastric emptying. (author)

  15. Do calories or osmolality determine gastric emptying

    International Nuclear Information System (INIS)

    Shafer, R.B.; Levine, A.S.; Marlette, J.M.; Morley, J.E.

    1984-01-01

    Recent animal studies suggest that gastric emptying is dependent on the caloric and osmotic content of the ingested food. These studies have involved intubation with infusion of liquid meals into the stomach. Scintigraphic methods, which are non-invasive and do not alter normal physiology, are now available for precise quantitation of gastric emptying. To study the role of calories and osmolality on gastric emptying, the authors employed a standardized /sup 99m/Tc-scrambled egg meal washed with 50 cc tap water in 10 normal human volunteers. A variety of simple and complex sugars, non-absorbable complex carbohydrate (polycose), medium chain fatty acid (MCFA) and gluten were dissolved in water and ingested with the test meal. Each subject acted as his own control. Coefficient of variation in control tests in each subject 12 weeks apart was 9.9%. Results showed that incremental glucose (25-66 gm) produced a linear increase in gastric emptying (T/2 control 50 +- 3, 25 gm 60 +- 3, 50 gm 79 +- 3 and 66 gm 102 +- 3 minutes). 25 gm fructose (T/2 59 +- 3 minutes) and 25 gm polycose (T/2 59 +- 3 minutes) had similar effects to glucose. 25 gm sucrose and 25 gm gluten did not significantly differ from controls. MCFA had an effect similar to 50 gm glucose - suggesting that calories are important in gastric emptying. However, 25 gm xylose markedly prolonged gastric emptying to 80 +- 5 minutes. The rank order for osmolality for substances tested MCFA = gluten < polycose < polycose < fructose < sucrose = glucose < xylose defined no relationship to gastric emptying. The authors' results suggest that neither calories nor osmolality alone determine gastric emptying. A specific food does not necessarily have the same effect on gastric emptying in different individuals

  16. Do calories or osmolality determine gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Shafer, R.B.; Levine, A.S.; Marlette, J.M.; Morley, J.E.

    1984-01-01

    Recent animal studies suggest that gastric emptying is dependent on the caloric and osmotic content of the ingested food. These studies have involved intubation with infusion of liquid meals into the stomach. Scintigraphic methods, which are non-invasive and do not alter normal physiology, are now available for precise quantitation of gastric emptying. To study the role of calories and osmolality on gastric emptying, the authors employed a standardized /sup 99m/Tc-scrambled egg meal washed with 50 cc tap water in 10 normal human volunteers. A variety of simple and complex sugars, non-absorbable complex carbohydrate (polycose), medium chain fatty acid (MCFA) and gluten were dissolved in water and ingested with the test meal. Each subject acted as his own control. Coefficient of variation in control tests in each subject 12 weeks apart was 9.9%. Results showed that incremental glucose (25-66 gm) produced a linear increase in gastric emptying (T/2 control 50 +- 3, 25 gm 60 +- 3, 50 gm 79 +- 3 and 66 gm 102 +- 3 minutes). 25 gm fructose (T/2 59 +- 3 minutes) and 25 gm polycose (T/2 59 +- 3 minutes) had similar effects to glucose. 25 gm sucrose and 25 gm gluten did not significantly differ from controls. MCFA had an effect similar to 50 gm glucose - suggesting that calories are important in gastric emptying. However, 25 gm xylose markedly prolonged gastric emptying to 80 +- 5 minutes. The rank order for osmolality for substances tested MCFA = gluten < polycose < polycose < fructose < sucrose = glucose < xylose defined no relationship to gastric emptying. The authors' results suggest that neither calories nor osmolality alone determine gastric emptying. A specific food does not necessarily have the same effect on gastric emptying in different individuals.

  17. Measurement of gastric emptying by intragastric gamma scintigraphy.

    Science.gov (United States)

    Malbert, C H; Mathis, C; Bobillier, E; Laplace, J P; Horowitz, M

    1997-09-01

    Gastric emptying is usually measured in animals and humans by dilution/sampling or external scintigraphy. These methods are either time consuming or require expensive equipment. The capacity of a miniature gamma counter positioned in the stomach to measure emptying of liquid and solid meals was evaluated. In eight conscious pigs fitted with gastric and duodenal cannulae, gastric emptying of saline (500 mL), dextrose (20%, 500 mL), porridge (300 g) and scrambled eggs (300 g), all labelled with 3.5 MBq 99mTC, was evaluated. When positioned in the antrum the probe was unable to quantify gastric emptying. In contrast, measurements of the fractional emptying of saline over 4-min periods by the probe positioned in the corpus and quantification of radioactivity in the duodenal effluent correlated closely (r = 0.88, P < 0.05). Gastric emptying (50% emptying time) of saline and both solid meals measured by the probe was not significantly different from quantification of the duodenal effluent volume. No difference was observed also for the dextrose meal but only while gastric acid secretion was suppressed by omeprazole. We conclude that an intragastric gamma counter permits measurement of gastric emptying of homogeneous meals provided meal stimulation of gastric secretion was not extensive. This was possible probably by monitoring emptying from the proximal stomach.

  18. Analysis in measurements of gastric emptying time

    International Nuclear Information System (INIS)

    Lee, Choon Ho; Lee, Man Koo

    1997-01-01

    Scintigraphic measurement of gastric emptying time has been reported to be influenced by the variation in depth of radionuclide within the stomach. This study was designed to clarify whether a part of the variability in gastric emptying could be ascribed to a relationship between anterior image, the total anteroposterior image and the tissue attenuation correction(geometric mean). A dual-head scintillation camera(ADAC, USA) was used to investigate effect of such changes. We were performed 16 normal subject gastric emptying studies with 99 mTC labelled scramble egg, milk and solid meal(610 Kcal, 300 g). The results are as follows; On anterior image, T 1/2 emptying time was delayed by 5 min, 6.5%(range : 3 ∼ 18 min, 5∼31.4%) compared with the geometric mean. But there was no different gastric emptying time between the total anteroposterior image and geometric mean. Therefore, if will be useful to use the method of geometric mean or the total anteroposterior image to evaluate the gastric emptying time accurately

  19. Analysis in measurements of gastric emptying time

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choon Ho [College of Medicine, Wonkwang Univ., Iksan (Korea, Republic of); Lee, Man Koo [Wonkwang Health Science College, Iksan (Korea, Republic of)

    1997-02-01

    Scintigraphic measurement of gastric emptying time has been reported to be influenced by the variation in depth of radionuclide within the stomach. This study was designed to clarify whether a part of the variability in gastric emptying could be ascribed to a relationship between anterior image, the total anteroposterior image and the tissue attenuation correction(geometric mean). A dual-head scintillation camera(ADAC, USA) was used to investigate effect of such changes. We were performed 16 normal subject gastric emptying studies with {sup 99}mTC labelled scramble egg, milk and solid meal(610 Kcal, 300 g). The results are as follows; On anterior image, T{sub 1/2} emptying time was delayed by 5 min, 6.5%(range : 3 {approx} 18 min, 5{approx}31.4%) compared with the geometric mean. But there was no different gastric emptying time between the total anteroposterior image and geometric mean. Therefore, if will be useful to use the method of geometric mean or the total anteroposterior image to evaluate the gastric emptying time accurately.

  20. Temperature effect on gastric emptying time of hybrid grouper (Epinephelus spp.)

    Energy Technology Data Exchange (ETDEWEB)

    De, Moumita; Ghaffar, Mazlan Abd. [School of Environmental and Natural Resource Sciences, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor (Malaysia); Das, Simon K. [School of Environmental and Natural Resource Sciences, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor, Malaysia and Marine Ecosystem Research Centre (EKOMAR), Faculty of Science and Technology, Universiti (Malaysia)

    2014-09-03

    Knowledge of fish gastric emptying time is a necessary component for understanding the fish feeding rates, energy budgets and commercial production of fishes in aquaculture. The hybrid grouper Epinephelus spp. is getting popular as a culture species in Malaysia for their faster growth rate compared to commonly cultured grouper species (giant grouper Epinephelus lanceolatus and tiger grouper Epinephelus fuscoguttatus). There are data suggests that elevated sea water temperature affects gastric emptying time (GET) of fishes. Hence, this study aims to study the GET of hybrid grouper at different temperature (22, 26, 30, 34°C) in laboratory condition with commercial diet pellet. The gastric emptying times (GETs) at different temperatures were determined X-radiographically, using barium sulfate (BaSO{sub 4}) as a contrast medium food marker. The food marker and X-radiography showed that initial voidance of fecal matter began 4-6 h after feeding at all temperature. The fastest GET (13 h) was obsereved in the 30°C group, whereas the longest (17 h) GET was seen in 22°C group fed with artificial diet pellet. Not much differences in GET were recorded between the 26 and 34°C groups as 34°C groups fed lesser amount compared to 26°C groups. Nevertheless a substantial delay in GET was observed in the 22°C group. The findings of this study suggest to culture hybrid grouper between 26 to 30°C with commercial diet pellet as this temperature ranges proliferate the faster digestion process which may contribute faster growth rate of this commerical important fish species. Overall, these findings may have important consequences for optimization of commercial production of hybrid grouper.

  1. Temperature effect on gastric emptying time of hybrid grouper (Epinephelus spp.)

    Science.gov (United States)

    De, Moumita; Ghaffar, Mazlan Abd.; Das, Simon K.

    2014-09-01

    Knowledge of fish gastric emptying time is a necessary component for understanding the fish feeding rates, energy budgets and commercial production of fishes in aquaculture. The hybrid grouper Epinephelus spp. is getting popular as a culture species in Malaysia for their faster growth rate compared to commonly cultured grouper species (giant grouper Epinephelus lanceolatus and tiger grouper Epinephelus fuscoguttatus). There are data suggests that elevated sea water temperature affects gastric emptying time (GET) of fishes. Hence, this study aims to study the GET of hybrid grouper at different temperature (22, 26, 30, 34°C) in laboratory condition with commercial diet pellet. The gastric emptying times (GETs) at different temperatures were determined X-radiographically, using barium sulfate (BaSO4) as a contrast medium food marker. The food marker and X-radiography showed that initial voidance of fecal matter began 4-6 h after feeding at all temperature. The fastest GET (13 h) was obsereved in the 30°C group, whereas the longest (17 h) GET was seen in 22°C group fed with artificial diet pellet. Not much differences in GET were recorded between the 26 and 34°C groups as 34°C groups fed lesser amount compared to 26°C groups. Nevertheless a substantial delay in GET was observed in the 22°C group. The findings of this study suggest to culture hybrid grouper between 26 to 30°C with commercial diet pellet as this temperature ranges proliferate the faster digestion process which may contribute faster growth rate of this commerical important fish species. Overall, these findings may have important consequences for optimization of commercial production of hybrid grouper.

  2. Temperature effect on gastric emptying time of hybrid grouper (Epinephelus spp.)

    International Nuclear Information System (INIS)

    De, Moumita; Ghaffar, Mazlan Abd.; Das, Simon K.

    2014-01-01

    Knowledge of fish gastric emptying time is a necessary component for understanding the fish feeding rates, energy budgets and commercial production of fishes in aquaculture. The hybrid grouper Epinephelus spp. is getting popular as a culture species in Malaysia for their faster growth rate compared to commonly cultured grouper species (giant grouper Epinephelus lanceolatus and tiger grouper Epinephelus fuscoguttatus). There are data suggests that elevated sea water temperature affects gastric emptying time (GET) of fishes. Hence, this study aims to study the GET of hybrid grouper at different temperature (22, 26, 30, 34°C) in laboratory condition with commercial diet pellet. The gastric emptying times (GETs) at different temperatures were determined X-radiographically, using barium sulfate (BaSO 4 ) as a contrast medium food marker. The food marker and X-radiography showed that initial voidance of fecal matter began 4-6 h after feeding at all temperature. The fastest GET (13 h) was obsereved in the 30°C group, whereas the longest (17 h) GET was seen in 22°C group fed with artificial diet pellet. Not much differences in GET were recorded between the 26 and 34°C groups as 34°C groups fed lesser amount compared to 26°C groups. Nevertheless a substantial delay in GET was observed in the 22°C group. The findings of this study suggest to culture hybrid grouper between 26 to 30°C with commercial diet pellet as this temperature ranges proliferate the faster digestion process which may contribute faster growth rate of this commerical important fish species. Overall, these findings may have important consequences for optimization of commercial production of hybrid grouper

  3. Comprehensive Comparison between Empty Nest and Non-Empty Nest Elderly: A Cross-Sectional Study among Rural Populations in Northeast China

    Directory of Open Access Journals (Sweden)

    Ye Chang

    2016-08-01

    Full Text Available This study aimed to comprehensively compare the general characteristics, lifestyles, serum parameters, ultrasonic cardiogram (UCG parameters, depression, quality of life, and various comorbidities between empty nest and non-empty nest elderly among rural populations in northeast China. This analysis was based on our previous study which was conducted from January 2012 to August 2013, using a multistage, stratified, random cluster sampling scheme. The final analyzed sample consisted of 3208 participants aged no less than 60 years, which was further classified into three groups: non-empty nest group, empty nest group (living as a couple, and empty nest group (living alone. More than half of the participants were empty nest elderly (60.5%. There were no significant statistical differences for serum parameters, UCG parameters, lifestyles, dietary pattern, and scores of Patient Health Questionnaire-9 (PHQ-9 and World Health Organization Quality of Life questionnaire, abbreviated version (WHOQOL-BREF among the three groups. Empty nest elderly showed no more risk for comorbidities such as general obesity, abdominal obesity, hyperuricemia, hyperhomocysteinemia, diabetes, dyslipidemia, left atrial enlargement (LAE, and stroke. Our study indicated that empty nest elderly showed no more risk for depression, low quality of life and comorbidities such as general obesity, abdominal obesity, hyperuricemia, hyperhomocysteinemia, diabetes, dyslipidemia, LAE, and stroke among rural populations in northeast China.

  4. Gastric emptying of a physiologic mixed solid-liquid meal

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, R.S.; Malmud, L.S.; Bandini, P.; Rock, E.

    1982-05-01

    The purposes of this study were to use a noninvasive scintigraphic technique to measure gastric emptying of liquids and solids simultaneously, to study the interactions between emptying of the liquid and solid components of meals in normal subjects, and to employ dual isotope gastric scintigraphy to evaluate gastric emptying of liquids and solids in patients with clinical evidence of gastric outlet obstruction. The solid component of the test meal consisted of chicken liver, labeled in vivo with /sup 99m/Tc sulfur colloid, and the liquid component was water mixed with /sup 111/In DTPA. The rates of emptying were quantitated using a gamma camera on line to a digital computer. Twenty normal subjects were studied using this combined solid-liquid meal. Ten of them also ingested a liquid meal alone and ten a solid meal alone. Liquid emptied from the stomach significantly more rapidly than did solids. The emptying curve for liquids was exponential compared to a linear emptying curve for solids. The gastric emptying rate of the liquid component was slowed significantly by simultaneous ingestion of solids, but the emptying rate of solids was not affected by liquids. Several patients with clinical gastric outlet obstruction were evaluated. Both combined and selective abnormalities for gastric emptying of liquids and solids were demonstrated.

  5. Abnormalities of esophageal and gastric emptying in progressive systemic sclerosis

    International Nuclear Information System (INIS)

    Maddern, G.J.; Horowitz, M.; Jamieson, G.G.; Chatterton, B.E.; Collins, P.J.; Roberts-Thomson, P.

    1984-01-01

    Gastric and esophageal emptying were assessed using scintigraphic techniques in 12 patients with progressive systemic sclerosis and 22 normal volunteers. Esophageal emptying was significantly delayed in the patient group, with 7 of the 12 patients beyond the normal range. Gastric emptying was slower in patients than in controls, with 9 patients being outside the normal range for solid emptying and 7 patients outside the normal range for liquid emptying. Findings from gastric and esophageal emptying tests generally correlated well with symptoms of dysphagia and gastroesophageal reflux. However, 2 patients with normal emptying studies had symptomatic heartburn, and 2 patients with delay of both solid and liquid gastric emptying gave no history of gastroesophageal reflux. Delayed gastric emptying may be an important factor in the development of upper gastrointestinal symptoms in patients with progressive systemic sclerosis

  6. Abnormalities of esophageal and gastric emptying in progressive systemic sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Maddern, G.J.; Horowitz, M.; Jamieson, G.G.; Chatterton, B.E.; Collins, P.J.; Roberts-Thomson, P.

    1984-10-01

    Gastric and esophageal emptying were assessed using scintigraphic techniques in 12 patients with progressive systemic sclerosis and 22 normal volunteers. Esophageal emptying was significantly delayed in the patient group, with 7 of the 12 patients beyond the normal range. Gastric emptying was slower in patients than in controls, with 9 patients being outside the normal range for solid emptying and 7 patients outside the normal range for liquid emptying. Findings from gastric and esophageal emptying tests generally correlated well with symptoms of dysphagia and gastroesophageal reflux. However, 2 patients with normal emptying studies had symptomatic heartburn, and 2 patients with delay of both solid and liquid gastric emptying gave no history of gastroesophageal reflux. Delayed gastric emptying may be an important factor in the development of upper gastrointestinal symptoms in patients with progressive systemic sclerosis.

  7. Empty calories and phantom fullness: a randomized trial studying the relative effects of energy density and viscosity on gastric emptying determined by MRI and satiety.

    Science.gov (United States)

    Camps, Guido; Mars, Monica; de Graaf, Cees; Smeets, Paul Am

    2016-07-01

    Stomach fullness is a determinant of satiety. Although both the viscosity and energy content have been shown to delay gastric emptying, their relative importance is not well understood. We compared the relative effects of and interactions between the viscosity and energy density on gastric emptying and perceived satiety. A total of 15 healthy men [mean ± SD age: 22.6 ± 2.4 y; body mass index (in kg/m(2)): 22.6 ± 1.8] participated in an experiment with a randomized 2 × 2 crossover design. Participants received dairy-based shakes (500 mL; 50% carbohydrate, 20% protein, and 30% fat) that differed in viscosity (thin and thick) and energy density [100 kcal (corresponding to 0.2 kcal/mL) compared with 500 kcal (corresponding to 1 kcal/mL)]. After ingestion, participants entered an MRI scanner where abdominal scans and oral appetite ratings on a 100-point scale were obtained every 10 min until 90 min after ingestion. From the scans, gastric content volumes were determined. Overall, the gastric emptying half-time (GE t50) was 54.7 ± 3.8 min. The thin 100-kcal shake had the lowest GE t50 of 26.5 ± 3.0 min, followed by the thick 100-kcal shake with a GE t50 of 41 ± 3.9 min and the thin 500-kcal shake with a GE t50 of 69.5 ± 5.9 min, and the thick 500-kcal shake had the highest GE t50 of 81.9 ± 8.3 min. With respect to appetite, the thick 100-kcal shake led to higher fullness (58 points at 40 min) than the thin 500-kcal shake (48 points at 40 min). Our results show that increasing the viscosity is less effective than increasing the energy density in slowing gastric emptying. However, the viscosity is more important to increase the perceived fullness. These results underscore the lack of the satiating efficiency of empty calories in quickly ingested drinks such as sodas. The increase in perceived fullness that is due solely to the increased viscosity, which is a phenomenon that we refer to as phantom fullness, may be useful in lowering energy intake. This trial was

  8. Effects of cholelithiasis and cholecystectomy on gastric emptying.

    Science.gov (United States)

    Köksoy, F N; Bulut, T; Köse, H; Soybir, G; Yalçin, O; Aker, Y

    1994-06-01

    In this prospective, clinical study, four groups, each consisting of 12 patients were established to determine how gastric emptying is influenced in cholelithiasis with accompanied flatulent dyspepsia and the relationship of symptoms and gastric emptying after cholecystectomy: group 1--healthy people; group 2--patients with dyspeptic cholelithiasis; group 3--patients with no dyspepsia after cholecystectomy; group 4--patients with dyspepsia after cholecystectomy. Groups are compared according to solid phase gastric emptying scintigraphies performed with Tc 99m sulphur colloid bound with scrambled eggs. Gastric emptying delayed in groups 2 (P 0.005). These results demonstrate that dyspepsia, in cholelithiasis and persisting after cholecystectomy, has a close relation with delay in gastric emptying.

  9. Effects of Swertia japonica extract and its main compound swertiamarin on gastric emptying and gastrointestinal motility in mice.

    Science.gov (United States)

    Kimura, Yoshiyuki; Sumiyoshi, Maho

    2011-09-01

    The Swertia japonica is used clinically as a remedy for gastrointestinal symptoms in Japan. We examined the effects of a S. japonica and swertiamarin on gastric emptying and gastrointestinal motility in atropine-, dopamine-, and 5-hydroxytryptamine (5-HT)-treated mice. All three preparations inhibited reductions in gastric emptying and gastrointestinal motility induced by dopamine (1mg/kg, intraperitoneal injection, ip). Neither the powder, swertiamarin, nor itopride had any effect on the reductions in gastric emptying and gastrointestinal motility caused by 5-HT (4 mg/kg, ip). These findings suggest that the powder and swertiamarin stimulate gastric emptying and gastrointestinal motility by inhibiting the dopamine D(2) receptor. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Gas Cylinder Safety, Course 9518

    Energy Technology Data Exchange (ETDEWEB)

    Glass, George [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-10-27

    This course, Gas Cylinder Safety (#9518), presents an overview of the hazards and controls associated with handling, storing, using, and transporting gas cylinders. Standard components and markings of gas cylinders are also presented, as well as the process for the procurement, delivery, and return of gas cylinders at Los Alamos National Laboratory (LANL).

  11. Preparation by alkaline treatment and detailed characterisation of empty hepatitis B virus core particles for vaccine and gene therapy applications

    Science.gov (United States)

    Strods, Arnis; Ose, Velta; Bogans, Janis; Cielens, Indulis; Kalnins, Gints; Radovica, Ilze; Kazaks, Andris; Pumpens, Paul; Renhofa, Regina

    2015-06-01

    Hepatitis B virus (HBV) core (HBc) virus-like particles (VLPs) are one of the most powerful protein engineering tools utilised to expose immunological epitopes and/or cell-targeting signals and for the packaging of genetic material and immune stimulatory sequences. Although HBc VLPs and their numerous derivatives are produced in highly efficient bacterial and yeast expression systems, the existing purification and packaging protocols are not sufficiently optimised and standardised. Here, a simple alkaline treatment method was employed for the complete removal of internal RNA from bacteria- and yeast-produced HBc VLPs and for the conversion of these VLPs into empty particles, without any damage to the VLP structure. The empty HBc VLPs were able to effectively package the added DNA and RNA sequences. Furthermore, the alkaline hydrolysis technology appeared efficient for the purification and packaging of four different HBc variants carrying lysine residues on the HBc VLP spikes. Utilising the introduced lysine residues and the intrinsic aspartic and glutamic acid residues exposed on the tips of the HBc spikes for chemical coupling of the chosen peptide and/or nucleic acid sequences ensured a standard and easy protocol for the further development of versatile HBc VLP-based vaccine and gene therapy applications.

  12. Effect of heat transfer in cylinder on air quantity of 4-stroke cycle gasoline engine; 4 Stroke gasoline engine no kyunyu shinkiryo ni oyobosu cylinder nai dennetsu no eikyo

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, M.; Oguri, Y.; Suzuki, T. [Sophia University, Tokyo (Japan). Faculty of Science and Technology

    2000-01-25

    Many papers concerning air quantity of 4-stroke cycle gasoline engine have been published. It has been reported in these papers that heat transfer in surface of cylinder and inlet port gives big influence to the air quantity. But it has not been clear which influence of heat transfer in cylinder and inlet port is strong. So the authors derived a function of the air quantity thermodynamically considering heat transfer, and examined which of influence of heat transfer was strong. The results show ; (1) The influence of heat transfer in cylinder is small (about 1%) at full load, and is also small (about 5%) at light load. (2) Heat transfer in cylinder almost increases the air quantity. (3) The influence of heat transfer in inlet port decreases the air quantity with around 30% greatly. (author)

  13. Intravenous erythromycin dramatically accelerates gastric emptying in gastroparesis diabeticorum and normals and abolishes the emptying discrimination between solids and liquids

    International Nuclear Information System (INIS)

    Urbain, J.L.; Vantrappen, G.; Janssens, J.; Van Cutsem, E.; Peeters, T.; De Roo, M.

    1990-01-01

    Erythromycin, a macrolide antibiotic, has recently been shown to have a motilin like effect on gastrointestinal muscle strips. In this study, we have evaluated the effect of erythromycin on patients with delayed gastric emptying and healthy subjects using the dual radionuclide technique. Twelve patients with gastroparesis diabeticorum and ten healthy age- and sex-matched controls were studied. Gastric emptying of solids and liquids was determined using 99mTc-SC scrambled egg and 111In-DTPA in water. Following a baseline study and on a separate day, each patient and control received a 15-min i.v. perfusion of erythromycin starting at meal ingestion. Eleven out of the 12 patients were restudied after a 3-wk oral administration. In patients and controls, i.v. erythromycin dramatically accelerated gastric emptying of both solids and liquids which were emptied at the same rate. After chronic oral administration, solid and liquid emptying remained significantly accelerated. Erythromycin appears to be a very powerful gastrokinetic drug. Derived compounds with the gastrokinetic effect and without the antibiotic activity could be useful in dyspeptic patients with delayed gastric emptying

  14. Intravenous erythromycin dramatically accelerates gastric emptying in gastroparesis diabeticorum and normals and abolishes the emptying discrimination between solids and liquids

    Energy Technology Data Exchange (ETDEWEB)

    Urbain, J.L.; Vantrappen, G.; Janssens, J.; Van Cutsem, E.; Peeters, T.; De Roo, M. (Univ. of Leuven (Belgium))

    1990-09-01

    Erythromycin, a macrolide antibiotic, has recently been shown to have a motilin like effect on gastrointestinal muscle strips. In this study, we have evaluated the effect of erythromycin on patients with delayed gastric emptying and healthy subjects using the dual radionuclide technique. Twelve patients with gastroparesis diabeticorum and ten healthy age- and sex-matched controls were studied. Gastric emptying of solids and liquids was determined using 99mTc-SC scrambled egg and 111In-DTPA in water. Following a baseline study and on a separate day, each patient and control received a 15-min i.v. perfusion of erythromycin starting at meal ingestion. Eleven out of the 12 patients were restudied after a 3-wk oral administration. In patients and controls, i.v. erythromycin dramatically accelerated gastric emptying of both solids and liquids which were emptied at the same rate. After chronic oral administration, solid and liquid emptying remained significantly accelerated. Erythromycin appears to be a very powerful gastrokinetic drug. Derived compounds with the gastrokinetic effect and without the antibiotic activity could be useful in dyspeptic patients with delayed gastric emptying.

  15. Analysis on Flow Induced Motion of Cylinders with Different Cross Sections and the Potential Capacity of Energy Transference from the Flow

    Directory of Open Access Journals (Sweden)

    Jijian Lian

    2017-01-01

    Full Text Available The energy in flow induced motion (FIM was harnessed in recent years. In this study, the energy transfer ratio was derived to estimate the energy transference from the flow to the FIM. Then the FIM characteristics and energy transference of cylinders with different cross sections were experimentally investigated. The main findings are listed as follows. (a Circular cylinders and diamond prisms both present a self-limited motion. The maximum amplitude ratio of circular cylinder is around 1~1.2 which is higher than that of diamond prism (0.4~0.5. (b Triangle prisms and right square prisms present a self-unlimited motion. For triangle prism, amplitude ratio increases over 1.8; for right square prisms, amplitude ratio reaches 1.2. (c The maximum transfer ratios of circular cylinder and triangle prism are 80% and 57%, respectively, which are much higher than those of other prisms, indicating that circular cylinder and triangle prism have better performances in energy transference. (d The transfer ratio is strongly dependent on the damping and mass; higher damping or mass will promote a higher transfer ratio. (e Beyond the critical transfer ratios, amplitude variation coefficients are around 10%~30% resulting in a better performance in stationarity.

  16. Lattice Boltzmann simulation of viscoelastic flow past a confined free rotating cylinder

    Science.gov (United States)

    Xia, Yi; Zhang, Peijie; Lin, Jianzhong; Ku, Xiaoke; Nie, Deming

    2018-05-01

    To study the dynamics of rigid body immersed in viscoelastic fluid, an Oldroyd-B fluid flow past an eccentrically situated, free rotating cylinder in a two-dimensional (2D) channel is simulated by a novel lattice Boltzmann method. Two distribution functions are employed, one of which is aimed to solve Navier-Stokes equation and the other to the constitutive equation, respectively. The unified interpolation bounce-back scheme is adopted to treat the moving curved boundary of cylinder, and the novel Galilean invariant momentum exchange method is utilized to obtain the hydrodynamic force and torque exerted on the cylinder. Results show that the center-fixed cylinder rotates inversely in the direction where a cylinder immersed in Newtonian fluid do, which generates a centerline-oriented lift force according to Magnus effect. The cylinder’s eccentricity, flow inertia, fluid elasticity and viscosity would affect the rotation of cylinder in different ways. The cylinder rotates more rapidly when located farther away from the centerline, and slows down when it is too close to the wall. The rotation frequency decreases with increasing Reynolds number, and larger rotation frequency responds to larger Weissenberg number and smaller viscosity ratio, indicating that the fluid elasticity and low solvent viscosity accelerates the flow-induced rotation of cylinder.

  17. Scintigraphic evaluation of gastric emptying and motility

    International Nuclear Information System (INIS)

    Linke, R.

    2003-01-01

    The stomach consists of two functionally distinct parts. The fundus and upper corpus mainly serve as a reservoir and exert primarily a tonic activity, which presses ingesta towards the antrum and duodenum. The phasic contractility of the lower corpus and antrum cause mechanical breakdown and mixing of the food particels. A complex regulation of these mechanisms provides a regular gastric emptying. Various disorders such as diabetes mellitus, mixed connective tissue diseases, gastritis, tumors, dyspeptic disorders but also drugs and gastric surgery may influence or impair gastric function and may cause typical symptoms such as upper abdominal discomfort, bloating, nausea and vomiting. However, the interpretation of gastrointestinal symptoms often is difficult. Radionuclide studies of gastric emptying and motility are the most physiologic tools available for studying gastric motor function. Gastric scintigraphy is non-invasive, uses physiologic meal and is quantitative. Emptying curves generated from the gastric ROI offer information whether a disorder is accompanied by a regular, fast or slow gastric emptying. Data on gastric contractions (amplitude and frequency) provide additional information to results obtained by conventional emptying studies. Depending on the underlying disorder, gastric emptying and peristalsis showed both corresponding and discrepant findings. Therefore, both parameters should be routinely assessed to further improve characterisation of gastric dysfunction by scintigraphy. (orig.) [de

  18. Effect of solids, caloric content on dual-phase gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Van Den Maegdenbergh, V.; Urbain, J.L.; Siegel, J.A.; Mortelmans, L.; De Roo, M. (Univ. Hospital Gasthuisberg, Leuven (Belgium) Temple Univ. Hospital, Philadelphia, PA (USA))

    1990-03-01

    The dual-phase gastric emptying technique is routinely employed to determine the differential emptying of solids and liquids in a wide spectrum of gastrointestinal diseases. Composition, acidity, volume, caloric density, physical form and viscosity of the test means have been shown to be important determinants for the quantitative evaluation of gastric emptying. In this study, the authors have evaluated the effect of increasing the caloric content of the solid portion of a physiologic test mean on both solid and liquid emptying kinetics in health male volunteers. They observed that increasing solid caloric content delayed emptying of both solids and liquids. For the solid phase, the delay was accounted for by a longer lag phase and decrease in emptying rate; for liquids a longer emptying rate was also obtained. They conclude that modification of the caloric content of the solid portion of a meal not only affects the emptying of the solid phase but also alters the emptying of the liquid component of the meal.

  19. Fiber Tracking Cylinder Nesting

    International Nuclear Information System (INIS)

    Stredde, H.

    1999-01-01

    The fiber tracker consists of 8 concentric carbon fiber cylinders of varying diameters, from 399mm to 1032.2mm and two different lengths. 1.66 and 2.52 meters. Each completed cylinder is covered over the entire o.d. with scintillating fiber ribbons with a connector on each ribbon. These ribbons are axial (parallel to the beam line) at one end and stereo (at 3 deg. to the beam line) at the other. The ribbon connectors have dowel pins which are used to match with the connectors on the wave guide ribbons. These dowel pins are also used during the nesting operation, locating and positioning measurements. The nesting operation is the insertion of one cylinder into another, aligning them with one another and fastening them together into a homogeneous assembly. For ease of assembly. the nesting operation is accomplished working from largest diameter to smallest. Although the completed assembly of all 8 cylinders glued and bolted together is very stiff. individual cylinders are relatively flexible. Therefore. during this operation, No.8 must be supported in a manner which maintains its integrity and yet allows the insertion of No.7. This is accomplished by essentially building a set of dummy end plates which replicate a No.9 cylinder. These end plates are mounted on a wheeled cart that becomes the nesting cart. Provisions for a protective cover fastened to these rings has been made and will be incorporated in finished product. These covers can be easily removed for access to No.8 and/or the connection of No.8 to No.9. Another wheeled cart, transfer cart, is used to push a completed cylinder into the cylinder(s) already mounted in the nesting cart.

  20. Rotation of an immersed cylinder sliding near a thin elastic coating

    Science.gov (United States)

    Rallabandi, Bhargav; Saintyves, Baudouin; Jules, Theo; Salez, Thomas; Schönecker, Clarissa; Mahadevan, L.; Stone, Howard A.

    2017-07-01

    It is known that an object translating parallel to a soft wall in a viscous fluid produces hydrodynamic stresses that deform the wall, which in turn results in a lift force on the object. Recent experiments with cylinders sliding under gravity near a soft incline, which confirmed theoretical arguments for the lift force, also reported an unexplained steady-state rotation of the cylinders [B. Saintyves et al., Proc. Natl. Acad. Sci. USA 113, 5847 (2016), 10.1073/pnas.1525462113]. Motivated by these observations, we show, in the lubrication limit, that an infinite cylinder that translates in a viscous fluid parallel to a soft wall at constant speed and separation distance must also rotate in order to remain free of torque. Using the Lorentz reciprocal theorem, we show analytically that for small deformations of the elastic layer, the angular velocity of the cylinder scales with the cube of the sliding speed. These predictions are confirmed numerically. We then apply the theory to the gravity-driven motion of a cylinder near a soft incline and find qualitative agreement with the experimental observations, namely, that a softer elastic layer results in a greater angular speed of the cylinder.

  1. Analysis of empty ATLAS pilot jobs

    CERN Document Server

    Love, Peter; The ATLAS collaboration

    2016-01-01

    The pilot model used by the ATLAS production system has been in use for many years. The model has proven to be a success with many advantages over push models. However one of the negative side-effects of using a pilot model is the presence of 'empty pilots' running on sites which consume a small amount of walltime and not running a useful payload job. The impact on a site can be significant with previous studies showing a total 0.5% walltime usage with no benefit to either the site or to ATLAS. Another impact is the number of empty pilots being processed by a site's Compute Element and batch system which can be 5% of the total number of pilots being handled. In this paper we review the latest statistics using both ATLAS and site data and highlight edge cases where the number of empty pilots dominate. We also study the effect of tuning the pilot factories to reduce the number of empty pilots.

  2. Gastric emptying of enteric-coated tablets

    International Nuclear Information System (INIS)

    Park, H.M.; Chernish, S.M.; Rosenek, B.D.; Brunelle, R.L.; Hargrove, B.; Wellman, H.N.

    1984-01-01

    To evaluate the gastric emptying time of pharmaceutical dosage forms in a clinical setting, a relatively simple dual-radionuclide technique was developed. Placebo tablets of six different combinations of shape and size were labeled with indium-111 DTPA and enteric coated. Six volunteers participated in a single-blind and crossover study. Tablets were given in the morning of a fasting stomach with 6 oz of water containing /sup 99m/Tc pertechnetate and continuously observed with a gamma camera. A scintigraph was obtained each minute. The results suggested that the size, shape, or volume of the tablet used in this study had no significant effect in the rate of gastric emptying. The tablets emptied erratically and unpredictably, depending upon their time of arrival in the stomach in relation to the occurrence of interdigestive myoelectric contractions. The method described is a relatively simple and accurate technique to allow one to follow the gastric emptying of tablets

  3. Antennas on circular cylinders

    DEFF Research Database (Denmark)

    Knudsen, H. L.

    1959-01-01

    On the basis of the results obtained by Silver and Saunders [4] for the field radiated from an arbitrary slot in a perfectly conducting circular cylinder, expressions have been derived for the field radiated by a narrow helical slot, with an arbitrary aperture field distribution, in a circular...... antenna in a circular cylinder. By a procedure similar to the one used by Silver and Saunders, expressions have been derived for the field radiated from an arbitrary surface current distribution on a cylinder surface coaxial with a perfectly conducting cylinder. The cases where the space between the two...

  4. Pouch emptying of solid foods after gastroplasty for morbid obesity

    DEFF Research Database (Denmark)

    Andersen, T; Pedersen, B H; Henriksen, Jens Henrik Sahl

    1985-01-01

    To obtain information on possible determinants of weight loss after horizontal gastroplasty, pouch emptying was prospectively investigated in 27 morbidly obese patients. A scintigraphic method was used. Examinations were carried out every 6 months until 2 years after surgery. Pouch emptying...... was described by means of delay, time until half emptying, mean transit time, and emptying rate. The measures all showed a significant (p less than 0.05) acceleration of pouch emptying during the first 6 months after gastroplasty. Thereafter pouch emptying was unaltered. No significant association could...

  5. Scintigraphic evaluation of gastric emptying: are radiolabeled solids necessary

    Energy Technology Data Exchange (ETDEWEB)

    Siegel, J.A.; Krevsky, B.; Maurer, A.H.; Charkes, N.D.; Fisher, R.S.; Malmud, L.S.

    1989-01-01

    A standard, dual-isotope meal (Tc-99m-egg sandwich and In-111 DTPA in water) was administered to 14 normal volunteers and 37 patients, who had not undergone gastric surgery, to determine if the emptying characteristics of the liquid phase alone could accurately predict delayed solid emptying. Delayed gastric emptying was defined clinically as a solid half-emptying time more than two standard deviations greater than the mean for normal volunteers. Linear regression analysis was performed on the natural logarithm of liquid fractional retention at each time interval to yield a slope and y-intercept for each subject. There was no significant difference (0.6 less than P less than 0.8) between volunteers and patients with normal solid emptying for the liquid slope. In patients who exhibited delayed gastric emptying for solids, the liquid slopes were significantly different from the normal values (P less than .001). There was a high correlation of liquid slope to solid half-emptying time in all patients and volunteers (r = -0.80, P less than .001). Comparison of the liquid slope measurement to solid half-emptying time criteria revealed a sensitivity of 96%, a specificity of 100%, and a predictive value of 100% for the slope test. These results suggest that delayed gastric emptying can be accurately detected with a liquid-solid meal using only a single-liquid label.

  6. Gastric emptying, glucose metabolism and gut hormones

    DEFF Research Database (Denmark)

    Vermeulen, Mechteld A R; Richir, Milan C; Garretsen, Martijn K

    2011-01-01

    To study the gastric-emptying rate and gut hormonal response of two carbohydrate-rich beverages. A specifically designed carbohydrate-rich beverage is currently used to support the surgical patient metabolically. Fruit-based beverages may also promote recovery, due to natural antioxidant and carb......To study the gastric-emptying rate and gut hormonal response of two carbohydrate-rich beverages. A specifically designed carbohydrate-rich beverage is currently used to support the surgical patient metabolically. Fruit-based beverages may also promote recovery, due to natural antioxidant...... and carbohydrate content. However, gastric emptying of fluids is influenced by its nutrient composition; hence, safety of preoperative carbohydrate loading should be confirmed. Because gut hormones link carbohydrate metabolism and gastric emptying, hormonal responses were studied....

  7. PREDICTING RELEVANT EMPTY SPOTS IN SOCIAL INTERACTION

    Institute of Scientific and Technical Information of China (English)

    Yoshiharu MAENO; Yukio OHSAWA

    2008-01-01

    An empty spot refers to an empty hard-to-fill space which can be found in the records of the social interaction, and is the clue to the persons in the underlying social network who do not appear in the records. This contribution addresses a problem to predict relevant empty spots in social interaction. Homogeneous and inhomogeneous networks are studied as a model underlying the social interaction. A heuristic predictor function method is presented as a new method to address the problem. Simulation experiment is demonstrated over a homogeneous network. A test data set in the form of market baskets is generated from the simulated communication. Precision to predict the empty spots is calculated to demonstrate the performance of the presented method.

  8. Wake flow behaviour behind a smaller cylinder oscillating in the wake of an upstream stationary cylinder

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Yangyang; Sun, Zhilin [Ocean College, Zhejiang University, Hangzhou 310058 (China); Tan, Danielle S [Maritime Research Centre, Nanyang Technological University, Singapore 639798 (Singapore); Yu, Dingyong [College of Engineering, Ocean University of China, 266100 (China); Tan, Soon Keat, E-mail: yygao@zju.edu.cn [Nanyang Environment and Water Research Institute, Nanyang Technological University, Singapore 639798 (Singapore)

    2014-04-01

    The flow patterns around a cylinder oscillating freely in the wake of a larger cylinder upstream were investigated using the particle image velocimetry technique. The upstream cylinder was fixed at both ends while the downstream smaller cylinder was held by springs such that it was free to oscillate in the transverse direction. The flow patterns, amplitudes of oscillation and vortex shedding frequencies were compared with those of a single cylinder. In the presence of the upstream cylinder, the three parameters characterizing the oscillation response of the smaller cylinder—amplitude of oscillation, vortex shedding frequency and Reynolds stresses—were greatly reduced. While their magnitude increased with gap ratio, these three parameters were still smaller than the corresponding magnitudes for a single oscillating cylinder. The peak values of turbulence statistics such as Reynolds shear stress and normal stress behind the oscillating downstream cylinder were similarly reduced, and increased with gap ratios. (paper)

  9. Control of flow structure in the wake region of circular cylinder with meshy wire in deep water

    Directory of Open Access Journals (Sweden)

    Burcu Oğuz

    2016-08-01

    Full Text Available In this study the aim is decreasing the effect and the intensity of the temporary loads resulted from vortex shedding that have an impact on the cylinder (chimneys, high buildings etc. located in deep water and the object or objects in the wake region and definition of the optimum values (wire thickness and porosity β With different thickness and different porosity ratios the effect of meshy wire that surrounded a circular cylinder of D=50 mm diameter was observed at Re_D=5000. The porosity ratios were four different values between a range of β=0.5-0.8 with an interval of 0.1. The thicknesses of wire were 1 mm, 2 mm, 3 mm and 4 mm. The flow structure in the wake region of circular cylinder was tried to be controlled by meshy wire that surrounded the cylinder. Experiments were carried out by using particle image velocimetry (PIV technique. Comparing with bare cylinder results, turbulence kinetic energy (TKE and Reynolds shear stress values increase with wire thicknesses of b=1 mm, 2 mm for all porosity ratios and decrease with b=3 mm, 4 mm. With porosity ratio of β=0.6 and wire thickness of b=4 mm TKE and Reynolds shear stress results show that meshy wire controls the flow in the wake region of the cylinder. Frequency value results also define that best flow control is obtained with β=0.6 and b=4 mm.

  10. Hydrolysis of cellulose and oil palm empty fruit bunches by using consortia of fungi isolated from the soil of Colombian high andean forest

    Directory of Open Access Journals (Sweden)

    Luz Aida Moya A

    2012-09-01

    Full Text Available Hydrolytic activity was evaluated in a mixture of supernatants produced by filamentous fungi grown individually on microcrystalline cellulose and empty fruit bunches. The strains that were used correspond to two types of isolates; the first was made from soil samples from a transect of a high andean forest of Colombia, in the Parque Natural Nacional de Los Nevados, where, based on previous studies, we selected the strains B7, B11, B11M and B19. The second isolate was obtained from a pool of oil palm empty fruit bunches (Eleaeis guinensis Jacq. in different states of decomposition on the Unipalma plantation located in the eastern plains; strains TA1 and TA2. To perform the hydrolysis of cellulose and empty fruit bunches, the previously obtained supernatants from each of the selected strains were cultivated for 300 hours in cellulose and characterized individually by endoglucanase, exoglucanase, and β-glucosidase activity. Individual supernatants were mixed at a 1:1 ratio to form consortia; and hydrolytic activity was evaluated in the substrates at two hours. The glucose concentration was determined by the 3,5-dinitrosalicylic acid (DNS method. The results show that hydrolysis of empty fruit bunch to glucose was favored by three pools of supernatants, with increases greater than 400% in comparison with the hydrolysis obtained by individual supernatants, demonstrating the potential to decompose palm empty fruit bunches; thereby contributing to the reduction of decay time of empty fruit bunches and the decrease of environmental and health problems

  11. Control of the flow in the annular region of a shrouded cylinder with splitter plate

    Directory of Open Access Journals (Sweden)

    Ozkan Gokturk Memduh

    2017-01-01

    Full Text Available In the present study, the flow control with a splitter plate was studied considering the annular region of a shrouded cylinder. The effect of splitter plate angle, α which was defined according to the cylinder centreline is investigated experimentally in deep water using Particle image Velocimetry (PIV technique and flow visualization by dye injection method. The range of splitter plate angle was selected within 60°≤ α ≤180° with an increment of 30°. The porosity of the shroud which is a perforated cylinder was selected as β=0.7 in order to have larger fluid entrainment through the cylinder. The results were compared with the no-plate case and showed that the splitter plate located in the annular region of shrouded cylinders is effective on reducing the turbulence levels just behind the cylinder base, as well as the near wake of the perforated shroud.

  12. Control of the flow in the annular region of a shrouded cylinder with splitter plate

    Science.gov (United States)

    Ozkan, Gokturk Memduh; Durhasan, Tahir; Pinar, Engin; Yenicun, Arda; Akilli, Huseyin; Sahin, Besir

    In the present study, the flow control with a splitter plate was studied considering the annular region of a shrouded cylinder. The effect of splitter plate angle, α which was defined according to the cylinder centreline is investigated experimentally in deep water using Particle image Velocimetry (PIV) technique and flow visualization by dye injection method. The range of splitter plate angle was selected within 60°≤ α ≤180° with an increment of 30°. The porosity of the shroud which is a perforated cylinder was selected as β=0.7 in order to have larger fluid entrainment through the cylinder. The results were compared with the no-plate case and showed that the splitter plate located in the annular region of shrouded cylinders is effective on reducing the turbulence levels just behind the cylinder base, as well as the near wake of the perforated shroud.

  13. Microstructure and Mechanical Properties of Heat-Treated B319 Alloy Diesel Cylinder Heads

    Science.gov (United States)

    Chaudhury, S. K.; Apelian, D.; Meyer, P.; Massinon, D.; Morichon, J.

    2015-07-01

    Microstructure and mechanical properties of B319 alloy diesel cylinder heads were investigated in this study. Cylinder heads were heat treated to T5, T6, and T7 tempers using fluidized bed technology. Three different fluidized beds were used, each to solutionize, quench, and age the castings. For comparative purposes, castings were also aged using conventional forced-air circulation electric-resistance furnace. Effects of processing parameters such as temperature, time, and heating rate on microstructural evolution and mechanical properties namely tensile properties and hardness of B319 alloy castings were studied. The number density and size range of precipitates were measured. Results show that the T5 temper has no effect on eutectic phases such as Si- and Fe-rich intermetallic, and Al2Cu. On contrary, both T6 and T7 tempers result in spherodization of the eutectic Si and partial dissolution of the Al2Cu phase. Prolonged solution heat treatment for 8 hours in fluidized bed results in limited dissolution of the secondary eutectic Al2Cu phase. Aging (T6, T7, and T5) results in precipitation of Al5Cu2Mg8Si6 and Al2Cu phases in B319 alloy. The number density of precipitates in T6 temper is greater than in T7 and T5 tempers. The number density of precipitates is also affected by the duration of solution heat treatment. In general, long solution heat treatment (8 hours) results in greater precipitate density than short solution treatment (2 hours). The distribution of precipitates is inhomogeneous and varied across the dendritic structure. In general, precipitation rate of Al5Cu2Mg8Si6 phase is greater near the periphery of the dendrite as compared to the center. This is because Al5Cu2Mg8Si6 nucleates on Si particle, grain boundaries, and triple junction between recrystallized Al grains and Si particles. Similarly, heterogeneous sites such as grain boundaries and Al/Si interface also act as nucleating sites for the precipitation of Al2Cu phase. In general, the

  14. An unattended verification station for UF6 cylinders: Field trial findings

    Science.gov (United States)

    Smith, L. E.; Miller, K. A.; McDonald, B. S.; Webster, J. B.; Zalavadia, M. A.; Garner, J. R.; Stewart, S. L.; Branney, S. J.; Todd, L. C.; Deshmukh, N. S.; Nordquist, H. A.; Kulisek, J. A.; Swinhoe, M. T.

    2017-12-01

    In recent years, the International Atomic Energy Agency (IAEA) has pursued innovative techniques and an integrated suite of safeguards measures to address the verification challenges posed by the front end of the nuclear fuel cycle. Among the unattended instruments currently being explored by the IAEA is an Unattended Cylinder Verification Station (UCVS), which could provide automated, independent verification of the declared relative enrichment, 235U mass, total uranium mass, and identification for all declared uranium hexafluoride cylinders in a facility (e.g., uranium enrichment plants and fuel fabrication plants). Under the auspices of the United States and European Commission Support Programs to the IAEA, a project was undertaken to assess the technical and practical viability of the UCVS concept. The first phase of the UCVS viability study was centered on a long-term field trial of a prototype UCVS system at a fuel fabrication facility. A key outcome of the study was a quantitative performance evaluation of two nondestructive assay (NDA) methods being considered for inclusion in a UCVS: Hybrid Enrichment Verification Array (HEVA), and Passive Neutron Enrichment Meter (PNEM). This paper provides a description of the UCVS prototype design and an overview of the long-term field trial. Analysis results and interpretation are presented with a focus on the performance of PNEM and HEVA for the assay of over 200 "typical" Type 30B cylinders, and the viability of an "NDA Fingerprint" concept as a high-fidelity means to periodically verify that material diversion has not occurred.

  15. Empty space-times with separable Hamilton-Jacobi equation

    International Nuclear Information System (INIS)

    Collinson, C.D.; Fugere, J.

    1977-01-01

    All empty space-times admitting a one-parameter group of motions and in which the Hamilton-Jacobi equation is (partially) separable are obtained. Several different cases of such empty space-times exist and the Riemann tensor is found to be either type D or N. The results presented here complete the search for empty space-times with separable Hamilton-Jacobi equation. (author)

  16. 75 FR 12713 - Airworthiness Directives; AVOX Systems and B/E Aerospace Oxygen Cylinders as Installed on Various...

    Science.gov (United States)

    2010-03-17

    ... proposed AD was prompted by the reported rupture of a high-pressure gaseous oxygen cylinder, which had...) This AD was prompted by the reported rupture of a high- pressure gaseous oxygen cylinder, which had... necessary oxygen supply for the flightcrew, and injury to cabin occupants or other support personnel. DATES...

  17. Wave forces on cylinder submerged horizontally in shallow water

    Energy Technology Data Exchange (ETDEWEB)

    Mitani, H; Sasaki, K; Kobayashi, T; Nomura, N; Kawabe, H; Sugimoto, H

    1976-12-01

    To estimate the wave forces on offshore and/or coastal structures, the ideal method is undoubtedly to obtain the more accurate solution of hydrodynamic equations under suitable boundary conditions. However, in practice, it is difficult to introduce precise solutions under present technical levels because some important problems still remain. Among them is the unsteady boundary layers with separation around the objects. Consequently, every effort is being made in this field to approximate these conditions. Among these approximations, the Diffraction Wave Theory and the Morrison's Method are the most famous means in practice, although both still have some problems. Some problems with the traditional Finite Amplitude Wave Theories such as Stokes and Cnoidal Wave Theories are examined, and by applying additional computed results to the Morrison's formula, the estimated formula for wave forces on a cylinder submerged horizontally in shallow water is introduced. Subsequently, the applicability of the formula and also the specific characteristics of wave forces on a horizontally settled cylinder are investigated in detail, attaching first importance to the distinctions from the vertically settled cylinder, based on the comparison of computed results with experimental results. The experiments were carried out on two different diameters of cylinder, 70 mm and 140 mm, and bottom slopes of the experimental tanks, /sup 1///sub 100/ and /sup 1///sub 30/, under various conditions varying water depth, wave period, wave height and also setting position of cylinder.

  18. Effect of longitudinal and transverse vibrations of an upstream square cylinder on vortex shedding behind two inline square cylinders

    International Nuclear Information System (INIS)

    Patil, Pratish P; Tiwari, Shaligram

    2009-01-01

    The characteristics of unsteady wakes behind a stationary square cylinder and another upstream vibrating square cylinder have been investigated numerically with the help of a developed computational code. The effect of longitudinal as well as transverse vibrations of the upstream cylinder is studied on the coupled wake between the two cylinders, which is found to control the vortex shedding behavior behind the downstream stationary cylinder. Computations are carried out for a fixed value of Reynolds number (Re = 200) and three different values of excitation frequencies of the upstream cylinder, namely less than, equal to and greater than the natural frequency of vortex shedding corresponding to flow past a stationary square cylinder. The vortex shedding characteristics of the unsteady wakes behind the vibrating and stationary cylinders are found to differ significantly for longitudinal and transverse modes of vibration of the upstream cylinder. The wake of the downstream stationary cylinder is found to depict a synchronization behavior with the upstream cylinder vibration. The spacing between the two cylinders has been identified to be the key parameter influencing the synchronization phenomenon. The effect of cylinder spacing on the wake synchronization and the hydrodynamic forces has been examined. In addition, a comparison of the drag forces for flow past transversely vibrating square and circular cylinders for similar amplitudes and frequencies of cylinder vibration has been presented while employing the tested computational code.

  19. The effects of cholelithiasis and cholecystectomy on gastric emptying.

    Science.gov (United States)

    Köksoy, F N; Bulut, T; Köse, H; Soybir, G; Yalçin, O; Aker, Y

    In this clinical study, four groups, each consisting of 12 patients are established to determine how gastric emptying is influenced in cholelithiasis with accompanied flatulent dyspepsia and the relationship of symptoms and gastric emptying after cholecystectomy. 1. group: healthy people, 2. group: patients with dyspeptic cholelithiasis, 3. group: patients who have no dyspepsia after cholecystectomy, 4. group: patients whose dyspepsia is continued after cholecystectomy. Groups are compared according to solid phase gastric emptying scintigraphies performed with Tc 99m sulfur colloid bound with scrambled eggs. Gastric emptying delayed in second (p 0.005). These results demonstrate that dyspepsia, in cholelithiasis and persisting after cholecystectomy have a close relation with delay in gastric emptying.

  20. Human postprandial gastric emptying of 1-3-millimeter spheres

    International Nuclear Information System (INIS)

    Meyer, J.H.; Elashoff, J.; Porter-Fink, V.; Dressman, J.; Amidon, G.L.

    1988-01-01

    Microspheres of pancreatin should empty from the stomachs of patients with pancreatic insufficiency as fast as food. The present study was undertaken in 26 healthy subjects to identify the size of spheres that would empty from the stomach with food and to determine whether different meals alter this size. Spheres of predefined sizes were labeled with /sup 113m/In or /sup 99m/Tc. Using a gamma-camera, we studied the concurrent gastric emptying of spheres labeled with /sup 113m/In and of chicken liver labeled with /sup 99m/Tc in 100-g, 154-kcal or 420-g, 919-kcal meals, or the concurrent emptying of 1-mm vs. larger spheres. One-millimeter spheres emptied consistently (p less than 0.01, paired t-test) faster than 2.4- or 3.2-mm spheres when ingested together with either the 420- or 100-g meals. Thus, in the 1-3-mm range of diameters, sphere size was a more important determinant of sphere emptying than meal size. Statistical analyses indicated that spheres 1.4 +/- 0.3 mm in diameter with a density of 1 empty at the same rate as /sup 99m/Tc-liver. Our data indicate some commercially marketed microspheres of pancreatin will empty too slowly to be effective in digestion of food

  1. Human postprandial gastric emptying of 1-3-millimeter spheres

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, J.H.; Elashoff, J.; Porter-Fink, V.; Dressman, J.; Amidon, G.L.

    1988-06-01

    Microspheres of pancreatin should empty from the stomachs of patients with pancreatic insufficiency as fast as food. The present study was undertaken in 26 healthy subjects to identify the size of spheres that would empty from the stomach with food and to determine whether different meals alter this size. Spheres of predefined sizes were labeled with /sup 113m/In or /sup 99m/Tc. Using a gamma-camera, we studied the concurrent gastric emptying of spheres labeled with /sup 113m/In and of chicken liver labeled with /sup 99m/Tc in 100-g, 154-kcal or 420-g, 919-kcal meals, or the concurrent emptying of 1-mm vs. larger spheres. One-millimeter spheres emptied consistently (p less than 0.01, paired t-test) faster than 2.4- or 3.2-mm spheres when ingested together with either the 420- or 100-g meals. Thus, in the 1-3-mm range of diameters, sphere size was a more important determinant of sphere emptying than meal size. Statistical analyses indicated that spheres 1.4 +/- 0.3 mm in diameter with a density of 1 empty at the same rate as /sup 99m/Tc-liver. Our data indicate some commercially marketed microspheres of pancreatin will empty too slowly to be effective in digestion of food.

  2. Emptiness is not so empty: The meaning of the Russian prefix вы- in the natural perfective verbs

    Directory of Open Access Journals (Sweden)

    Tatiana Pozolotina

    2009-01-01

    Full Text Available This paper analyzes the meaning of the so-called "empty" prefix вы- (‘out-' of natural perfective verbs in the Russian language. It is argued that the prefix is not semantically empty, but displays meanings that can be analyzed as a radial category.

  3. Slower eating rate is independent to gastric emptying in obese minipigs.

    Science.gov (United States)

    Val-Laillet, D; Guérin, S; Malbert, C H

    2010-11-02

    The aim of our study was to investigate whether the altered eating behavior observed in the context of a diet-induced metabolic syndrome is related to changes of the gastric emptying and autonomic balance. Eight adult male Göttingen minipigs were subjected during 5months to ad libitum Western diet (WD). Several factors were compared between the lean (before WD) and obese conditions: general activity and eating behavior, gastric emptying, adiposity, glycemia and insulinemia during IVGTT, and heart rate variability (HRV). In our model, obesity did not alter the gastric emptying (258±26 vs. 256±14 min, P>0.10) but induced insulin resistance: increased basal insulinemia (12.6±0.8 to 36.6±6.1 mU/l, P5E-4±0.7E-4 to 2.5E-4±0.2E-4 min(-1) per mU.l(-1) of insulin, P0.10). Fed ad libitum with WD, animals overate durably (P<0.001). During a 30-min meal test though, the ingestion speed, the food ingested (1076±48 vs. 520±52 g) and energy intake decreased in the obese condition (P<0.05), which can be explained by the fragmentation of the daily caloric intake. These data suggest that the slower eating rate and increased number of meals observed in obese minipigs without neuropathy is independent to gastric emptying. The explanation may be sought rather in central modifications induced by obesity that might modify the food perception and/or motivation. Copyright © 2010 Elsevier Inc. All rights reserved.

  4. Empty Sella Syndrome

    Science.gov (United States)

    ... Publications Definition Empty Sella Syndrome (ESS) is a disorder that involves the sella turcica , a bony structure at the base of the brain that surrounds and protects the pituitary gland. ESS is often discovered during radiological imaging tests ...

  5. A study of the dynamics of gastric emptying

    International Nuclear Information System (INIS)

    Shibatsuji, Hiroshi

    1985-01-01

    Factors influencing gastric emptying were studied by measuring gastric emptying time (GET) with RI experimentally and clinically. The restlts are as follows: 1. The parasympathetic blockers suppressed gastric emptying but the parasympathetic stimulater did not accelerate it. 2. Posture of the subject in measurement influenced gastric emptying and GET was reduced in order of prone, sitting and supine positions. 3. In cases of gastric and duodenal ulcer, there were differences of GET between pre-operation and post-operation depending on the methods of operation. 4. The GET was measured to investigate the gastric emptying of liquid and solid food by double RI tracer method, using 99m Tc-DTPA and 111 In-DTPA which were measured separately. The GET of liquid food was faster than that of solid food and was influenced by the stickiness of coexistent solid food. On the other hand, the GET of solid food tended to be faster with increasing stickiness. (author)

  6. Dose-dependent effect of ghrelin on gastric emptying in rats and the related mechanism of action

    Directory of Open Access Journals (Sweden)

    Shu-Guang Cao

    2016-03-01

    Full Text Available The aim of this study was to investigate the dose-dependent effect of ghrelin on gastric emptying in rats and the related mechanism of action. Sixty Wistar rats were randomized into control and test groups, which respectively received intraperitoneal injection of normal saline and ghrelin at different doses (0.5 nmol/kg, 1.0 nmol/kg, 1.5 nmol/kg, 2.0 nmol/kg, and 2.5 nmol/kg. After 45 minutes, all rats were gavaged with semisolid paste. The gastric emptying rate was determined 30 minutes later, and the plasma cholecystokinin level was tested by radioimmunoassay. The mean gastric emptying rate in the test groups was significantly higher than in the control group (38.24 ± 7.15% and 27.18 ± 2.37%, respectively, p < 0.05. Medium and high doses of ghrelin (1.0 nmol/kg, 1.5 nmol/kg, 2.0 nmol/kg, and 2.5 nmol/kg, but not low dose (0.5 nmol/kg, accelerated the gastric emptying. In addition, the plasma cholecystokinin level in the test groups was significantly higher than in the control group (p < 0.01. The gastric emptying rate was positively correlated with the plasma cholecystokinin level (p < 0.01. Intraperitoneal injection of ghrelin at medium and high doses significantly accelerated gastric emptying in rats.

  7. Dynamic Friction Performance of a Pneumatic Cylinder with Al2O3 Film on Cylinder Surface.

    Science.gov (United States)

    Chang, Ho; Lan, Chou-Wei; Wang, Hao-Xian

    2015-11-01

    A friction force system is proposed for accurately measuring friction force and motion properties produced by reciprocating motion of piston in a pneumatic cylinder. In this study, the proposed system is used to measure the effects of lubricating greases of different viscosities on the friction properties of pneumatic cylinder, and improvement of stick-slip motion for the cylinder bore by anodizing processes. A servo motor-driven ball screw is used to drive the pneumatic cylinder to be tested and to measure the change in friction force of the pneumatic cylinder. Experimental results show, that under similar test conditions, the lubricating grease with viscosity VG100 is best suited for measuring reciprocating motion of the piston of pneumatic cylinder. The wear experiment showed that, in the Al2O3 film obtained at a preset voltage 40 V in the anodic process, the friction coefficient and hardness decreased by 55% and increased by 274% respectively, thus achieving a good tribology and wear resistance. Additionally, the amplitude variation in the friction force of the pneumatic cylinder wall that received the anodizing treatment was substantially reduced. Additionally, the stick-slip motion of the pneumatic cylinder during low-speed motion was substantially improved.

  8. 49 CFR 178.35 - General requirements for specification cylinders.

    Science.gov (United States)

    2010-10-01

    ... of part 107 of this chapter; or (2) For DOT Specifications 3B, 3BN, 3E, 4B, 4BA, 4D (water capacity...) The word “spun” or “plug” must be placed near the DOT specification marking when an end closure in the... certifies that the processes of manufacture and heat treatment of cylinders were observed and found...

  9. The One-Pot Directed Assembly of Cylinder-Forming Block Copolymer on Adjacent Chemical Patterns for Bimodal Patterning.

    Science.gov (United States)

    Chang, Tzu-Hsuan; Xiong, Shisheng; Liu, Chi-Chun; Liu, Dong; Nealey, Paul F; Ma, Zhenqiang

    2017-09-01

    The direct self-assembly of cylinder-forming poly(styrene-block-methyl-methacrylate) (PS-b-PMMA) block copolymer is successfully assembled into two orientations, according to the underlying guiding pattern in different areas. Lying-down and perpendicular cylinders are formed, respectively, depending on the design of chemical pattern: sparse line/space pattern or hexagonal dot array. The first chemical pattern composed of prepatterned cross-linked polystyrene (XPS) line/space structure has a period (L S ) equal to twice the intercylinder period of the block copolymer (L 0 ). The PS-b-PMMA thin film on the prepared chemical template after thermal annealing forms a lying-down cylinder morphology when the width of the PS strips is less than the width of PS block in the PS-b-PMMA block copolymer. The morphology is only applicable at the discrete thickness of the PS-b-PMMA film. In addition to forming the lying-down cylinders directly on the XPS guiding pattern, the cylinder-forming block copolymer can also be assembled in a perpendicular way on the second guiding pattern (the hexagonal dot array). The block copolymer films are registered into two orientations in a single directed self-assembly process. The features of the assembled patterns are successfully transferred down to the silicon oxide substrate. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Variability of gastric emptying measurements in man employing standardized radiolabeled meals

    International Nuclear Information System (INIS)

    Brophy, C.M.; Moore, J.G.; Christian, P.E.; Egger, M.J.; Taylor, A.T.

    1986-01-01

    Radiolabeled liquid and solid portions of standardized 300-g meals were administered on four different study days to eight healthy subjects in an attempt to define the range of inter- and intrasubject variability in gastric emptying. Meal half emptying times, analysis of variance, and intraclass correlations were computed and compared within and between subjects. The mean solid half emptying time was 58 +/- 17 min (range 29-92), while the mean liquid half emptying time was 24 +/- 8 min (range 12-37). A nested random effects analysis of variance showed moderate intrasubject variability for solid emptying and high intrasubject variability for liquid emptying. The variability of solid and liquid emptying was comparable and relatively large when compared with other reports in the literature. The isotopic method for measuring gastric emptying is a valuable tool for investigating problems in gastric pathophysiology, particularly when differences between groups of subjects are sought. However, meal emptying time is a variable phenomenon in healthy subjects with significant inter- and intraindividual day-to-day differences. These day-to-day variations in gastric emptying must be considered in interpreting individual study results

  11. Variability of gastric emptying measurements in man employing standardized radiolabeled meals

    Energy Technology Data Exchange (ETDEWEB)

    Brophy, C.M.; Moore, J.G.; Christian, P.E.; Egger, M.J.; Taylor, A.T.

    1986-08-01

    Radiolabeled liquid and solid portions of standardized 300-g meals were administered on four different study days to eight healthy subjects in an attempt to define the range of inter- and intrasubject variability in gastric emptying. Meal half emptying times, analysis of variance, and intraclass correlations were computed and compared within and between subjects. The mean solid half emptying time was 58 +/- 17 min (range 29-92), while the mean liquid half emptying time was 24 +/- 8 min (range 12-37). A nested random effects analysis of variance showed moderate intrasubject variability for solid emptying and high intrasubject variability for liquid emptying. The variability of solid and liquid emptying was comparable and relatively large when compared with other reports in the literature. The isotopic method for measuring gastric emptying is a valuable tool for investigating problems in gastric pathophysiology, particularly when differences between groups of subjects are sought. However, meal emptying time is a variable phenomenon in healthy subjects with significant inter- and intraindividual day-to-day differences. These day-to-day variations in gastric emptying must be considered in interpreting individual study results.

  12. Review article: gastric emptying in functional gastrointestinal disorders.

    LENUS (Irish Health Repository)

    Quigley, E M M

    2012-02-03

    Although delayed gastric emptying has been described in several functional gastrointestinal disorders, and appears to be especially common in functional dyspepsia, the relationship of this finding to symptoms and basic pathophysiology is difficult to define. The delineation of the interactions between delayed gastric emptying, on the one hand, and symptom pathogenesis, on the other, has been hampered by several factors. These include the limitations of the methodology itself, the extent of overlap between the various functional disorders and the sensitivity of gastric emptying to factors external to the stomach, be they elsewhere within the gastrointestinal tract, in the central nervous system or in the environment. In many instances, delayed gastric emptying is an epiphenomenon, reflecting the overlap between inadequately defined functional syndromes, shared pathophysiology or the activation of physiological interactions between the various organs of the gut. In others, it may imply a truly diffuse motor disorder. The disappointments attendant on attempts to alleviate symptoms through approaches designed to accelerate gastric emptying should therefore not come as a surprise. Pending the definition of the true significance of delayed gastric emptying in all functional gastrointestinal disorders, caution should be exerted in the interpretation of this finding in a patient with functional symptoms.

  13. Three-dimensional study of flow past a square cylinder at low Reynolds numbers

    International Nuclear Information System (INIS)

    Saha, A.K.; Biswas, G.; Muralidhar, K.

    2003-01-01

    The spatial evolution of vortices and transition to three-dimensionality in the wake of a square cylinder have been numerically studied. A Reynolds number range between 150 and 500 has been considered. Starting from the two-dimensional Karman vortex street, the transition to three-dimensionality is found to take place at a Reynolds number between 150 and 175. The three-dimensional wake of the square cylinder has been characterized using indicators appropriate for the wake of a bluff body as described by the earlier workers. In these terms, the secondary vortices of Mode-A are seen to persist over the Reynolds number range of 175-240. At about a Reynolds number of 250, Mode-B secondary vortices are present, these having predominantly small-scale structures. The transitional flow around a square cylinder exhibits an intermittent low frequency modulation due to the formation of a large-scale irregularity in the near-wake, called vortex dislocation. The superposition of vortex dislocation and the Mode-A vortices leads to a new pattern, labelled as Mode-A with dislocations. The results for the square cylinder are in good accordance with the three-dimensional modes of transition that are well-known in the circular cylinder wake. In the case of a circular cylinder, the transition from periodic vortex shedding to Mode-A is characterized by a discontinuity in the Strouhal number-Reynolds number relationship at about a Reynolds of 190. The transition from Mode-A to Mode-B is characterized by a second discontinuity in the frequency law at a Reynolds number of ∼250. The numerical computations of the present study with a square cylinder show that the values of the Strouhal number and the time-averaged drag-coefficient are closely associated with each other over the range of Reynolds numbers of interest and reflect the spatial structure of the wake

  14. 48 CFR 52.247-66 - Returnable Cylinders.

    Science.gov (United States)

    2010-10-01

    ... Cylinders (MAY 1994) (a) Cylinder, referred to in this clause, is a pressure vessel designed for pressures... clause. (c) For each cylinder lost or damaged beyond repair while in the Government's possession, the... associated replacement values.] These cylinders shall become Government property. (d) If any lost cylinder is...

  15. Scintigraphic demonstration of single- or two-phase gastric emptying in diabetics

    International Nuclear Information System (INIS)

    Eikman, E.A.; Leichter, S.; Waldholtz, B.; Tenorio, L.; Brady, P.

    1989-01-01

    This paper discusses how a modified scintigraphic test of gastric emptying revealed two types of abnormal gastric emptying in diabetic patients. After ingestion of 100 mL of cooked egg whites labeled with 0.5 mCi of Tc-99m sulfur colloid, the geometric mean stomach radioactivity was recorded serially for 90 minutes. Linear regression computed for the log of radioactivity versus time facilitated recognition of changes in gastric emptying. In 16 of 25 consecutive diabetic patients with postprandial symptoms, initial slow emptying (half-life,>100 minutes) was observed. Single-phase emptying was shown in seven of these patients. In nine patients, the slow-emptying phase lasted up to 50 minutes, followed by a distinct second phase of normal or rapid emptying (half-life, <40 minutes). The existence of different gastric emptying implies differing mechanisms of delay and may be important in treatment

  16. Cylinder with differential piston for mass measurements

    Energy Technology Data Exchange (ETDEWEB)

    Bordeaşu, I.; Bălăşoiu, V. [Universitatea Politehnica din Timişoara, Timosoara (Romania); Hadă, A. [UniversitateaPolitehnicaBucureşti, Bucureşti (Romania); Popoviciu, M. [Academy of Romanian ScientistsTimişoara Branch (Romania)

    2007-07-01

    The paper presents a cylinder with differential piston, adapted for measuring the weight of fixed objects such as: fuel tanks (regardless of their capacity), bunkers and silos for all kind of materials, or mobile objects such as: automobiles, trucks, locomotives and railway cars. Although, the cylinder with differential piston is used on a large scale in hydraulic drive or hydraulic control circuits, till now it was not used as constituent part for weight measurements devices. The novelty of the present paper is precisely the use of the device for such purposes. Based on a computation algorithm, the paper presents the general design (assembly), of the device used for weighing important masses (1…. 100 tones). The fundamental idea consist in the fact that, a mass over 10 tones may be weighted with a helicoidally spring subjected to an axial force between 0 and 3000 N, with a deflection of about 30 mm. Simultaneously with the mechanical part, the electronic recording system is also described. The great advantage of the presented device consist in the fact that it can be used in heavy polluted atmosphere or difficult topographic conditions as a result of both the small dimensions and the protection systems adopted. Keywords: cylinder hydraulic with differential piston, hydrostatic pressure, measuring devices.

  17. Stomach emptiness in fishes: Sources of variation and study design implications

    Science.gov (United States)

    Vinson, M.R.; Angradi, T.R.

    2011-01-01

    This study summarizes fish stomach content data from 369,000 fish from 402 species in 1,096 collections and reports on the percentage of individuals with empty stomachs. The mean percentage of individuals with empty stomachs among all species, locations, habitats, seasons, regions, and collection methods was 26.4%. Mean percentage of individuals with empty stomachs varied significantly among fish collection gear types, taxonomic orders, trophic groups, feeding behaviors, and habitats, and with species length at maturity. Most of the variation in percentage of individuals with empty stomachs was explained by species length at maturity, fish collection gear type, and two autecological factors: trophic group (piscivore percentage of individuals with empty stomachs > non-piscivore percentage of individuals with empty stomachs) and feeding habitat (water column feeder percentage of individuals with empty stomachs > benthic feeder percentage of individuals with empty stomachs). After accounting for variation with fish length, the percentage of individuals with empty stomachs did not vary with the stomach removal collection method (dissection vs. gastric lavage), feeding time (diurnal or nocturnal), or time of collection (day or night). The percentage of individuals with empty stomachs was similar between fresh and saltwater fish, but differed within finer habitat classifications and appeared to follow a general prey availability or productivity gradient: percentage of individuals with empty stomachs of open ocean collections > estuary collections, lentic > lotic, and pelagic > littoral. Gear type (active or passive) was the most influential factor affecting the occurrence of empty stomachs that can be readily controlled by researchers.

  18. Xylitol vs glucose: Effect on the rate of gastric emptying and motilin, insulin, and gastric inhibitory polypeptide release

    International Nuclear Information System (INIS)

    Salminen, E.K.; Salminen, S.J.; Porkka, L.; Kwasowski, P.; Marks, V.; Koivistoinen, P.E.

    1989-01-01

    The effect of xylitol and glucose on the rate of gastric emptying and intestinal transit and on motilin, gastric inhibitory polypeptide (GIP), and insulin release were studied in human volunteers. A single oral dose of 200 mL water containing 30 g glucose or 30 g xylitol, mixed with a 99m technetium-tin (99mTc-Sn) colloid, was used. Similar dosing without the label was used in motilin, GIP, and insulin studies. Xylitol decreased the rate of gastric emptying but concomitantly accelerated intestinal transit compared with glucose. The half-times for gastric emptying were 77.5 +/- 4.6 and 39.8 +/- 3.4 min after ingestion of xylitol and glucose solutions, respectively. Glucose suppressed motilin and stimulated GIP secretion; xylitol stimulated motilin secretion but had no effect on GIP, which is currently the main candidate for the role of enterogastrone. The accelerated intestinal transit and increase in plasma motilin observed after xylitol ingestion were thought to be causally related to the diarrhea and gastrointestinal discomfort produced by it

  19. Simulation of empty container logistic management at depot

    Science.gov (United States)

    Sze, San-Nah; Sek, Siaw-Ying Doreen; Chiew, Kang-Leng; Tiong, Wei-King

    2017-07-01

    This study focuses on the empty container management problem in a deficit regional area. Deficit area is the area having more export activities than the import activities, which always have a shortage of empty container. This environment has challenged the trading companies in the decision making in distributing the empty containers. A simulation model that fit to the environment is developed. Besides, a simple heuristic algorithm with some hard and soft constraints consideration are proposed to plan the logistic of empty container supply. Then, the feasible route with the minimum cost will be determined by applying the proposed heuristic algorithm. The heuristic algorithm can be divided into three main phases which are data sorting, data assigning and time window updating.

  20. Flow over an inline oscillating circular cylinder in the wake of a stationary circular cylinder

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yang; Zhu, Keqiang, E-mail: zhukeqiang@nbu.edu.cn [Faculty of Maritime and Transportation, Ningbo University, Ningbo 315211 (China)

    2017-02-15

    Flow interference between an upstream stationary cylinder and an inline oscillating cylinder is studied with the lattice Boltzmann method. With a fixed Reynolds number Re  = 100 and pitch ratio L / D  = 4, the effects of oscillation amplitude A / D  = [0.25, 1] and frequency f {sub e}/ f {sub s} = [0.5, 2] are investigated. The wake response state is categorized into lock-in and non-lock-in. The lock-in zone in the bifurcation diagram of amplitude versus frequency is discontinuous. Response states of upstream and downstream wakes are similar under the conditions of small amplitude or low frequency. However, with large oscillating parameters, the two wakes are prone to be in different states as the flow field becomes irregular. Two distinct flow regimes have been identified, i.e., single-cylinder and two-cylinder shedding regimes. The presence of single-cylinder shedding regime is attributed to the low shedding frequency of the downstream cylinder at large amplitude. Hydrodynamic forces of the oscillating tandem system are discussed. The results reveal that forces on the two cylinders behave differently and that the absence of vortices in the gap flow significantly reduces the forces exerting on the tandem system. (paper)

  1. An efficient cost function for the optimization of an n-layered isotropic cloaked cylinder

    International Nuclear Information System (INIS)

    Paul, Jason V; Collins, Peter J; Coutu, Ronald A Jr

    2013-01-01

    In this paper, we present an efficient cost function for optimizing n-layered isotropic cloaked cylinders. Cost function efficiency is achieved by extracting the expression for the angle independent scatterer contribution of an associated Green's function. Therefore, since this cost function is not a function of angle, accounting for every bistatic angle is not necessary and thus more efficient than other cost functions. With this general and efficient cost function, isotropic cloaked cylinders can be optimized for many layers and material parameters. To demonstrate this, optimized cloaked cylinders made of 10, 20 and 30 equal thickness layers are presented for TE and TM incidence. Furthermore, we study the effect layer thickness has on optimized cloaks by optimizing a 10 layer cloaked cylinder over the material parameters and individual layer thicknesses. The optimized material parameters in this effort do not exhibit the dual nature that is evident in the ideal transformation optics design. This indicates that the inevitable field penetration and subsequent PEC boundary condition at the cylinder must be taken into account for an optimal cloaked cylinder design. Furthermore, a more effective cloaked cylinder can be designed by optimizing both layer thickness and material parameters than by additional layers alone. (paper)

  2. Reduction of sound transmission across plenum windows by incorporating an array of rigid cylinders

    Science.gov (United States)

    Tang, S. K.

    2018-02-01

    The potential improvement of plenum window noise reduction by installing rigid circular cylinder arrays into the window cavity is investigated numerically using the finite-element method in this study. A two-dimensional approach is adopted. The sound transmission characteristics and propagation within the plenum window are also examined in detail. Results show that the installation of the cylinders in general gives rise to broadband improvement of noise reduction across a plenum window regardless of the direction of sound incidence. Such acoustical performance becomes better when more cylinder columns are installed, but it is suggested that the number of cylinder rows should not exceed two. Results also show that the cylinder positions relative to the nodal/anti-nodal planes of the acoustic modes are crucial in the noise reduction enhancement mechanisms. Noise reduction can further be enhanced by staggering the cylinder rows, such that each cylinder row supports the development of a different acoustic mode. For the simple cylinder arrangements considered in this study, the traffic noise reduction enhancement observed in this study can be as high as 4-5 dB, which is already comparable to or higher than the maximum achieved by installing sound absorption into a plenum window.

  3. Gastric emptying studies in the morbidly obese before and after gastroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Christian, P.E.; Datz, F.L.; Moore, J.G.

    1986-11-01

    Dual isotope gastric emptying studies were performed on 16 morbidly obese patients before and after gastroplasty to determine the effect of this surgery on the rate of emptying. The solid and liquid phases of gastric emptying were compared with a normal control group. In the 900-g and 50-g meals there was a significant difference in the mean half emptying time between solid and liquid phases of emptying (p less than 0.05). Pre-operatively, the 900-g meal half emptying times of both solids and liquids and the 50-g liquid phase meal did not differ significantly between obese patients and the control group. However, in the solid phase of the 50-g meal obese patients differed significantly from a control group (p = 0.007). Three months after gastroplasty, gastric emptying of 50-g meals from the total stomach was not significantly changed from the pre-operative 50-g meal values in ten of 12 patients (p less than 0.05) and no change in total stomach emptying times were seen at 12 mo compared to the 3-mo study (p less than 0.05). Emptying of the pouch alone for both solids and liquids was significantly faster than the pre-operative and postoperative total stomach studies. Gastric emptying in the obese is normal with large meals, but is delayed in small meals. In most patients, gastroplasty does not result in slower emptying of meals.

  4. Postpyloric regulation of gastric emptying in rhesus monkeys.

    Science.gov (United States)

    McHugh, P R; Moran, T H; Wirth, J B

    1982-09-01

    Saline (0.9% NaCl) empties rapidly and exponentially from the stomach of the rhesus monkey, but glucose solutions empty at a calorie-constant rate of 0.4 kcal/min. By means of indwelling intragastric and intraduodenal cannulae we can demonstrate an inhibition on the delivery of saline from the stomach provoked by glucose placed beyond the pylorus. The inhibition varies directly with the glucose calories in the intestine and averages 2.5 min/kcal. That these two results (0.4 kcal/min and 2.5 min/kcal) are reciprocals suggests a feedback inhibition on the gastric emptying of nutrients arising from beyond the pylorus and adequate to explain the rate of glucose delivery to the intestine. A control theory description of gastric emptying that includes such feedback regulation can be derived from these data to explain the different gastric emptying patterns of nutrients and nonnutrient solutions. These patterns give this visceral system a precision in its management of nutrients that can provide information crucial to preabsorptive satiety.

  5. Variability of gastric emptying time using standardized radiolabeled meals

    International Nuclear Information System (INIS)

    Christian, P.E.; Brophy, C.M.; Egger, M.J.; Taylor, A.; Moore, J.G.

    1984-01-01

    To define the range of inter- and intra-subject variability on gastric emptying measurements, eight healthy male subjects (ages 19-40) received meals on four separate occasions. The meal consisted of 150 g of beef stew labeled with Tc-99m SC labeled liver (600 μCi) and 150 g of orange juice containing In-111 DTPA (100 μCi) as the solid- and liquid-phase markers respectively. Images of the solid and liquid phases were obtained at 20 min intervals immediately after meal ingestion. The stomach region was selected from digital images and data were corrected for radionuclide interference, radioactive decay and the geometric mean of anterior and posterior counts. More absolute variability was seen with the solid than the liquid marker emptying for the group. The mean solid half-emptying time was 58 +- 17 min (range 29-92) while the mean liquid half-emptying time was 24 +- 8 min (range 12-37). A nested random effects analysis of variance showed moderate intra-subject variability for solid half-emptying times (rho = 0.4594), and high intra-subject variability was implied by a low correlation (rho = 0.2084) for liquid half-emptying. The average inter-subject differences were 58.3% of the total variance for solids (rho = 0.0017). For liquids, the inter-subject variability was 69.1% of the total variance, but was only suggestive of statistical significance (rho = 0.0666). The normal half emptying time for gastric emptying of liquids and solids is a variable phenomenon in healthy subjects and has great inter- and intra-individual day-to-day differences

  6. Variability of gastric emptying time using standardized radiolabeled meals

    Energy Technology Data Exchange (ETDEWEB)

    Christian, P.E.; Brophy, C.M.; Egger, M.J.; Taylor, A.; Moore, J.G.

    1984-01-01

    To define the range of inter- and intra-subject variability on gastric emptying measurements, eight healthy male subjects (ages 19-40) received meals on four separate occasions. The meal consisted of 150 g of beef stew labeled with Tc-99m SC labeled liver (600 ..mu..Ci) and 150 g of orange juice containing In-111 DTPA (100 ..mu..Ci) as the solid- and liquid-phase markers respectively. Images of the solid and liquid phases were obtained at 20 min intervals immediately after meal ingestion. The stomach region was selected from digital images and data were corrected for radionuclide interference, radioactive decay and the geometric mean of anterior and posterior counts. More absolute variability was seen with the solid than the liquid marker emptying for the group. The mean solid half-emptying time was 58 +- 17 min (range 29-92) while the mean liquid half-emptying time was 24 +- 8 min (range 12-37). A nested random effects analysis of variance showed moderate intra-subject variability for solid half-emptying times (rho = 0.4594), and high intra-subject variability was implied by a low correlation (rho = 0.2084) for liquid half-emptying. The average inter-subject differences were 58.3% of the total variance for solids (rho = 0.0017). For liquids, the inter-subject variability was 69.1% of the total variance, but was only suggestive of statistical significance (rho = 0.0666). The normal half emptying time for gastric emptying of liquids and solids is a variable phenomenon in healthy subjects and has great inter- and intra-individual day-to-day differences.

  7. Calculated leaching of certain fission products from a cylinder of French glass

    International Nuclear Information System (INIS)

    Blomqvist, G.

    1977-07-01

    The probable total leaching of the most important fission products and actinides have been tabulated for a cylinder of French HLW glass with approximately 9 percent fission products. The calculations cover the period between 30 and 10000 years after removal from the reactor. The cylinder is of the type planned for the introduction of the HLW into Swedish crystalline rocks. All the components are supposed to have the same leach rate. The calculations also include the probable thickness of eroded glass layer/year. (author)

  8. The empty wagons adjustment algorithm of Chinese heavy-haul railway

    International Nuclear Information System (INIS)

    Zhang, Jinchuan; Yang, Hao; Wei, Yuguang; Shang, Pan

    2016-01-01

    The paper studied the problem of empty wagons adjustment of Chinese heavy-haul railway. Firstly, based on the existing study of the empty wagons adjustment of heavy-haul railway in the world, Chinese heavy-haul railway was analyzed, especially the mode of transportation organization and characteristics of empty wagons adjustment. Secondly, the optimization model was set up to solve the empty wagons adjustment of heavy-haul railway and the model took the minimum idling period as the function goal. Finally, through application and solution of one case, validity and practicability of model and algorithm had been proved. So, the model could offer decision support to transport enterprises on adjusting empty wagons.

  9. Observation of a Relaxed Plasma State in a Quasi-Infinite Cylinder

    Science.gov (United States)

    Gray, T.; Brown, M. R.; Dandurand, D.

    2013-02-01

    A helical relaxed plasma state is observed in a long cylindrical volume. The cylinder is long enough so that the predicted minimum energy state is a close approximation to the infinite cylinder solution. The plasma is injected at v≥50km/s by a coaxial magnetized plasma gun located at one end of the cylindrical volume. The relaxed state is rapidly attained in 1-2 axial Alfvén times after initiation of the plasma. Magnetic data are favorably compared with an analytical model. Magnetic data exhibit broadband fluctuations of the measured axial modes during the formation period. The broadband activity rapidly decays as the energy condenses into the lowest energy mode, which is in agreement with the minimum energy eigenstate of ∇×B=λB.

  10. Two dimensional numerical analysis of aerodynamic characteristics for rotating cylinder on concentrated air flow

    Science.gov (United States)

    Alias, M. S.; Rafie, A. S. Mohd; Marzuki, O. F.; Hamid, M. F. Abdul; Chia, C. C.

    2017-12-01

    Over the years, many studies have demonstrated the feasibility of the Magnus effect on spinning cylinder to improve lift production, which can be much higher than the traditional airfoil shape. With this characteristic, spinning cylinder might be used as a lifting device for short take-off distance aircraft or unmanned aerial vehicle (UAV). Nonetheless, there is still a gap in research to explain the use of spinning cylinder as a good lifting device. Computational method is used for this study to analyse the Magnus effect, in which two-dimensional finite element numerical analysis method is applied using ANSYS FLUENT software to examine the coefficients of lift and drag, and to investigate the flow field around the rotating cylinder surface body. Cylinder size of 30mm is chosen and several configurations in steady and concentrated air flows have been evaluated. All in all, it can be concluded that, with the right configuration of the concentrated air flow setup, the rotating cylinder can be used as a lifting device for very short take-off since it can produce very high coefficient of lift (2.5 times higher) compared with steady air flow configuration.

  11. Dual Circularly Polarized Omnidirectional Antenna with Slot Array on Coaxial Cylinder

    Directory of Open Access Journals (Sweden)

    Bin Zhou

    2015-01-01

    Full Text Available A dual circularly polarized (CP omnidirectional antenna based on slot array in coaxial cylinder structure is presented in this paper. It is constructed by perpendicular slot pairs around and along the axis of the coaxial cylinder to realize the omnidirectional CP property, and two ports are assigned in its two sides as left hand circularly polarized (LHCP port and right hand circularly polarized (RHCP port, respectively. The proposed antenna achieves a bandwidth of 16.4% ranging from 5.05 to 5.95 GHz with an isolation higher than 15 dB between the two CP ports, and the return loss (RL is higher than 10 dB within the bandwidth in both of the two ports. From the measured results, the average axial ratio (AR of the proposed antenna in omnidirectional plane is lower than 1.5 dB.

  12. Analysis of the Indented Cylinder by the use of Computer Vision

    DEFF Research Database (Denmark)

    Buus, Ole Thomsen

    and two journal papers. These three papers, referred to as Paper I, Paper II, and Paper III can be found in Appendix A, B, and C, respectively. These three papers represent the very first examples of published/submitted work that thoroughly analyse and verify the separation ability of the indented...... in system identification of the indented cylinder. The technical solutions developed are currently novel and represent an ideal platform for future applied research into empirical model development. Finally, this work should also be considered as an early step toward a paradigm shift where the best...... parameters for the indented cylinder are not mainly determined by “rule of thumb” and other forms of heuristics, but are instead optimized parameters tied to an actual theory of seed separation in the indented cylinder....

  13. Flow past a rotating cylinder

    Science.gov (United States)

    Mittal, Sanjay; Kumar, Bhaskar

    2003-02-01

    Flow past a spinning circular cylinder placed in a uniform stream is investigated via two-dimensional computations. A stabilized finite element method is utilized to solve the incompressible Navier Stokes equations in the primitive variables formulation. The Reynolds number based on the cylinder diameter and free-stream speed of the flow is 200. The non-dimensional rotation rate, [alpha] (ratio of the surface speed and freestream speed), is varied between 0 and 5. The time integration of the flow equations is carried out for very large dimensionless time. Vortex shedding is observed for [alpha] cylinder. The results from the stability analysis for the rotating cylinder are in very good agreement with those from direct numerical simulations. For large rotation rates, very large lift coefficients can be obtained via the Magnus effect. However, the power requirement for rotating the cylinder increases rapidly with rotation rate.

  14. Floquet stability analysis of viscoelastic flow over a cylinder

    KAUST Repository

    Richter, David

    2011-06-01

    A Floquet linear stability analysis has been performed on a viscoelastic cylinder wake. The FENE-P model is used to represent the non-Newtonian fluid, and the analysis is done using a modified version of an existing nonlinear code to compute the linearized initial value problem governing the growth of small perturbations in the wake. By measuring instability growth rates over a wide range of disturbance spanwise wavenumbers α, the effects of viscoelasticity were identified and compared directly to Newtonian results.At a Reynolds number of 300, two unstable bands exist over the range 0. ≤ α≤ 10 for Newtonian flow. For the low α band, associated with the "mode A" wake instability, a monotonic reduction in growth rates is found for increasing polymer extensibility L. For the high α band, associated with the "mode B" instability, first a rise, then a significant decrease to a stable state is found for the instability growth rates as L is increased from L= 10 to L= 30. The mechanism behind this stabilization of both mode A and mode B instabilities is due to the change of the base flow, rather than a direct effect of viscoelasticity on the perturbation. © 2011 Elsevier B.V.

  15. Floquet stability analysis of viscoelastic flow over a cylinder

    KAUST Repository

    Richter, David; Shaqfeh, Eric S.G.; Iaccarino, Gianluca

    2011-01-01

    A Floquet linear stability analysis has been performed on a viscoelastic cylinder wake. The FENE-P model is used to represent the non-Newtonian fluid, and the analysis is done using a modified version of an existing nonlinear code to compute the linearized initial value problem governing the growth of small perturbations in the wake. By measuring instability growth rates over a wide range of disturbance spanwise wavenumbers α, the effects of viscoelasticity were identified and compared directly to Newtonian results.At a Reynolds number of 300, two unstable bands exist over the range 0. ≤ α≤ 10 for Newtonian flow. For the low α band, associated with the "mode A" wake instability, a monotonic reduction in growth rates is found for increasing polymer extensibility L. For the high α band, associated with the "mode B" instability, first a rise, then a significant decrease to a stable state is found for the instability growth rates as L is increased from L= 10 to L= 30. The mechanism behind this stabilization of both mode A and mode B instabilities is due to the change of the base flow, rather than a direct effect of viscoelasticity on the perturbation. © 2011 Elsevier B.V.

  16. THE PAPER CHARACTERISTICS FROM COMBINATION OF RICE HUSKS AND EMPTY FRUIT BUNCHES

    Directory of Open Access Journals (Sweden)

    Yuli Ristianingsih

    2017-10-01

    Full Text Available Abstract- Rice husk and empty fruit bunches are agricultural and plantation wastes which have fiber cellulose and hemicellulose, it can be converted to pulp and paper. This research aims to study the effect of NaOH concentration (2, 4, 6 and 8% w/v and raw material composition to pulp yield and to study characteristics of the paper combination of rice husk and empty fruit bunches using soda process based on SEM and XRD analysis. This research using soda process because it is suitable for non-wood raw materials, low cost operations and not use sulfur compounds. Dry raw materials are mixed with NaOH and digesting using autoclave (100°C, 1 atm for 60 minutes. NaOH concentration optimum used in the pulping process a combination rice husk and empty fruit bunches (1:3, 1:2, 1:1, 2:1 and 3:1 and then cooled for 30 minutes. Pulp is bleached with NaClO 5.25% (v / v, then formed and dried as paper. The lowest pulp yield obtained in a ratio of 2: 1 is 27.6%. Based on the observation of SEM known the fiber of rice husk and empty fruit bunches is 5.88 to 9.8 μm and 8.82 to 14.71 μm, while based on XRD observations, chemical treatment can improve the characteristic of peak intensity on paper combination. The highest advances of peak intensity in the 1:3 ratio is 71.28% (cellulose I dan 83.33% (cellulose II.

  17. THE PAPER CHARACTERISTICS FROM COMBINATION OF RICE HUSKS AND EMPTY FRUIT BUNCHES

    Directory of Open Access Journals (Sweden)

    Yuli Ristianinsih

    2017-10-01

    Full Text Available Rice husk and empty fruit bunches are agricultural and plantation wastes which have fiber cellulose and hemicellulose, it can be converted to pulp and paper. This research aims to study the effect of NaOH concentration (2, 4, 6 and 8% w/v and raw material composition to pulp yield and to study characteristics of the paper combination of rice husk and empty fruit bunches using soda process based on SEM and XRD analysis. This research using soda process because it is suitable for non-wood raw materials, low cost operations and not use sulfur compounds. Dry raw materials are mixed with NaOH and digesting using autoclave (100°C, 1 atm for 60 minutes. NaOH concentration optimum used in the pulping process a combination rice husk and empty fruit bunches (1:3, 1:2, 1:1, 2:1 and 3:1 and then cooled for 30 minutes. Pulp is bleached with NaClO 5.25% (v / v, then formed and dried as paper. The lowest pulp yield obtained in a ratio of 2: 1 is 27.6%. Based on the observation of SEM known the fiber of rice husk and empty fruit bunches is 5.88 to 9.8 μm and 8.82 to 14.71 μm, while based on XRD observations, chemical treatment can improve the characteristic of peak intensity on paper combination. The highest advances of peak intensity in the 1:3 ratio is 71.28% (cellulose I dan 83.33% (cellulose II.

  18. A gluten-free vegan meal for gastric emptying scintigraphy: establishment of reference values and its utilization in the evaluation of diabetic gastroparesis.

    Science.gov (United States)

    Somasundaram, Vijay Harish; Subramanyam, Padma; Palaniswamy, Shanmuga Sundaram

    2014-11-01

    The aim of this study was to describe the preparation of radiolabeled idli (savory cake) meal for use as an alternate to the egg white sandwich (EWS) meal in gastric emptying scintigraphy (GES). Furthermore, the aim of this study was to establish normal emptying rates for this meal and present our experience in using it in the evaluation of diabetic gastroparesis. The meal was prepared using a universally available packaged mix labeled with 1 mCi 99mTc sulfur colloid, and the stability of labeling was tested up to 4 hours in simulated gastric fluid. One hundred thirteen healthy volunteers (aged 20-78 years; 54 women, 59 men) underwent GES study using the idli meal. Gastric retention at one-half, 1, 2, and 4 hours after ingestion of the meal was estimated, and the normal limits were set using the fifth and 95th percentile values at each period. Having established its normal emptying rates, the idli meal was further used to evaluate 70 patients suspected with diabetic gastroparesis. The idli meal, with a calorific value ≈282 kcal, has a relatively higher fat content (8% of total mass) than EWS. More than 96% of 99mTc sulfur colloid remained bound to the meal after 4 hours suspension in simulated gastric fluid. Gastric retention greater than 30% and greater than 6% at 2 hours and 4 hours, respectively, indicated delayed gastric emptying, whereas retention less than 30% at 1 hour suggested rapid emptying. Among patients suspected with diabetic gastroparesis, delayed gastric emptying was identified in 76%, and rapid emptying was seen in 4.2%. Radiolabeled idli meal is a good alternative to EWS meal for routine GES, especially among patients with specific dietary restrictions.

  19. Inhibitory effects of xylitol on gastric emptying and food intake

    International Nuclear Information System (INIS)

    Shafer, R.B.; Levine, A.S.; Marlette, J.M.; Morley, J.E.

    1985-01-01

    The authors have previously shown, using a 99m-Tc scrambled egg meal, that pentose sugars (i.e. xylose and arabinose) markedly prolong gastric emptying. Others have reported that slowing of gastric emptying may decrease appetite and thus decrease food intake. In the present study, the authors utilized the effects of xylitol (an FDA-approved pentose sugar) on gastric emptying to study the correlation between gastric emptying and food intake. Initially, gastric emptying was measured in human volunteers utilizing a standardized 99m-Tc-scrambled egg meal washed with 50 cc tap water. Results demonstrated a significant reduction in food intake (892 +- 65 kcal with water vs 654 +- 26 kcal following the ingestion of 25 gm xylitol (p<0.05). We conclude that the effect of pentose sugars in prolonging gastric emptying directly influences food intake and contributes to early satiety. The data suggest a role of xylitol as an essentially non-caloric food additive potentially important in diet control

  20. Inhibitory effects of xylitol on gastric emptying and food intake

    Energy Technology Data Exchange (ETDEWEB)

    Shafer, R.B.; Levine, A.S.; Marlette, J.M.; Morley, J.E.

    1985-05-01

    The authors have previously shown, using a 99m-Tc scrambled egg meal, that pentose sugars (i.e. xylose and arabinose) markedly prolong gastric emptying. Others have reported that slowing of gastric emptying may decrease appetite and thus decrease food intake. In the present study, the authors utilized the effects of xylitol (an FDA-approved pentose sugar) on gastric emptying to study the correlation between gastric emptying and food intake. Initially, gastric emptying was measured in human volunteers utilizing a standardized 99m-Tc-scrambled egg meal washed with 50 cc tap water. Results demonstrated a significant reduction in food intake (892 +- 65 kcal with water vs 654 +- 26 kcal following the ingestion of 25 gm xylitol (p<0.05). We conclude that the effect of pentose sugars in prolonging gastric emptying directly influences food intake and contributes to early satiety. The data suggest a role of xylitol as an essentially non-caloric food additive potentially important in diet control.

  1. Malrotation discovered during routine radionuclide gastric emptying study

    Energy Technology Data Exchange (ETDEWEB)

    Kovanlikaya, A. [Div. of Nuclear Radiology, Children`s Hospital of Los Angeles, Univ. of Southern California (United States); Miller, J.H. [Div. of Nuclear Radiology, Children`s Hospital of Los Angeles, Univ. of Southern California (United States); Williams, H.T. [Div. of Nuclear Radiology, Children`s Hospital of Los Angeles, Univ. of Southern California (United States)

    1996-08-01

    In infants with recurrent vomiting, and especially bilious vomiting, the algorithmic approaches is to perform conventional barium upper gastrointestinal radiography to rule out malrotation and midgut volvulus, which are surgical emergencies. However, children with protracted vomiting and failure to thrive are candidates for medical treatment. These children are often evaluated by radionuclide gastric emptying studies to assess gastric emptying. Three patients are presented in whom the radionclude gastric emptying study revealed the presence of a malrotation anomaly which had been undetected by antecedent barium gastrointestinal radiographic studies. (orig.)

  2. Malrotation discovered during routine radionuclide gastric emptying study

    International Nuclear Information System (INIS)

    Kovanlikaya, A.; Miller, J.H.; Williams, H.T.

    1996-01-01

    In infants with recurrent vomiting, and especially bilious vomiting, the algorithmic approaches is to perform conventional barium upper gastrointestinal radiography to rule out malrotation and midgut volvulus, which are surgical emergencies. However, children with protracted vomiting and failure to thrive are candidates for medical treatment. These children are often evaluated by radionuclide gastric emptying studies to assess gastric emptying. Three patients are presented in whom the radionclude gastric emptying study revealed the presence of a malrotation anomaly which had been undetected by antecedent barium gastrointestinal radiographic studies. (orig.)

  3. Gas cylinder disposal pit remediation waste minimization and management

    International Nuclear Information System (INIS)

    Alas, C.A.; Solow, A.; Criswell, C.W.; Spengler, D.; Brannon, R.; Schwender, J.M.; Eckman, C.K.; Rusthoven, T.

    1995-01-01

    A remediation of a gas cylinder disposal pit at Sandia National Laboratories, New Mexico has recently been completed. The cleanup prevented possible spontaneous releases of hazardous gases from corroded cylinders that may have affected nearby active test areas at Sandia's Technical Area III. Special waste management, safety, and quality plans were developed and strictly implemented for this project. The project was conceived from a waste management perspective, and waste minimization and management were built into the planning and implementation phases. The site layout was planned to accommodate light and heavy equipment, storage of large quantities of suspect soil, and special areas to stage and treat gases and reactive chemicals removed from the pit, as well as radiation protection areas. Excavation was a tightly controlled activity using experienced gas cylinder and reactive chemical specialists. Hazardous operations were conducted at night under lights, to allow nearby daytime operations to function unhindered. The quality assurance plan provided specific control of, and documentation for, critical decisions, as well as the record of daily operations. Both hand and heavy equipment excavation techniques were utilized. Hand excavation techniques were utilized. Hand excavation techniques allows sealed glass containers to be exhumed unharmed. In the end, several dozen thermal batteries; 5 pounds (2.3 kg) of lithium metal; 6.6 pounds (3.0 kg) of rubidium metal; several kilograms of unknown chemicals; 140 cubic yards (107 cubic meters) of thorium-contaminated soil; 270 cubic yards (205 cubic meters) of chromium-contaminated soil; and 450 gas cylinders, including 97 intact cylinders containing inert, flammable, toxic, corrosive, or oxidizing gases were removed and effectively managed to minimize waste

  4. Gastric emptying and dyspeptic symptoms in the irritable bowel syndrome

    NARCIS (Netherlands)

    van Wijk, H. J.; Smout, A. J.; Akkermans, L. M.; Roelofs, J. M.; ten Thije, O. J.

    1992-01-01

    Many patients with irritable bowel syndrome (IBS) have symptoms suggestive of disturbances in gastric emptying, but so far no abnormalities in gastric emptying have been demonstrated in these patients. We studied gastric emptying of a solid meal with a 99mTc-labeled pancake in 16 healthy volunteers

  5. Effect of Yifukang oral liquid on gastric emptying and intestinal peristalsis in mice

    Science.gov (United States)

    Sun, Jianhua; Li, Jun; Li, Xianyu; Hao, Shaojun; Guo, Junyi; Ma, Zhenzhen; Zhang, Zhengchen

    2018-04-01

    To observe the effect of Yifukang oral liquid on gastric emptying and intestinal peristalsis in mice. Methods: 60 mice were randomly divided into 5 groups. The suspension of Baohe Pill and the same volume of normal saline group were given once a day for 7 days. After the last administration for 30 minutes, 0.25 ml of 0.04% phenolic red solution was administered by stomach. After 20 minutes, the animals were killed, the stomach was removed, the gastric contents were cleaned, and the lotion 5ml was centrifuged. The absorbance of the supernatant was measured by TU-1901 ultraviolet spectrophotometer at the wavelength of 560nm. The residual rate of gastric phenolic red was calculated. Rate was used to evaluate gastric emptying velocity.60 mice were randomly divided into five groups: group 5, large, medium, small Yifukang oral liquid dosage group, pill suspension and the same volume normal saline. After 20 min after the last dose of carbon powder suspension, the mice were sacrificed, the abdominal cavity was cut open, the intestine of the ileocecum was cut off, the intestinal mesentery was separated, the total length of the small intestine (cm) was measured, and the distance (cm) in the small intestine was measured, and the end-of-carbon propulsion rate was calculated. Compared with the blank group, small dose of Yi Fu Kang group and Baohe Pill group could significantly promote the ability of gastric emptying in mice. Compared with the blank group, small dose group and rehabilitation benefits Baohewan group can significantly promote the gastric emptying ability of mice (Pmice. Yi Fu Kang oral liquid group could significantly increase the percentage of small intestine carbon powder(Pmice (P<0.05). Yi Fukang oral liquid has the effect of promoting gastric emptying and small intestinal peristalsis.

  6. Gastric emptying in patients with gastric ulcer

    Energy Technology Data Exchange (ETDEWEB)

    Harding, L.K.; Anselmi, M.; Donovan, I.A.; Alexander-Williams, J. (Dudley Road Hospital, Birmingham (UK); Birmingham General Hospital (UK))

    1982-06-01

    The estimated volume of meal in the stomach 30 mins after sup(113m)In-DTPA administration was determined in patients with gastric ulcer and normal controls by 1) relating counts in the stomach to those in the whole field of view of the gamma camera and 2) aspirations. In the normal controls there was no significant difference between the two methods but in the gastric ulcer patients, the gamma camera method predicted significantly more meal in the stomach than was recovered by aspiration. It was suggested that the large low lying stomach found in gastric ulcer disease causes extensive overlap of the small bowel and invalidates measurements of gastric emptying made by a gamma camera.

  7. Gastric emptying in patients with gastric ulcer

    International Nuclear Information System (INIS)

    Harding, L.K.; Anselmi, M.; Donovan, I.A.; Alexander-Williams, J.

    1982-01-01

    The estimated volume of meal in the stomach 30 mins after sup(113m)In-DTPA administration was determined in patients with gastric ulcer and normal controls by 1) relating counts in the stomach to those in the whole field of view of the gamma camera and 2) aspirations. In the normal controls there was no significant difference between the two methods but in the gastric ulcer patients, the gamma camera method predicted significantly more meal in the stomach than was recovered by aspiration. It was suggested that the large low lying stomach found in gastric ulcer disease causes extensive overlap of the small bowel and invalidates measurements of gastric emptying made by a gamma camera. (U.K.)

  8. Sub-wavelength resonances in polygonal metamaterial cylinders

    DEFF Research Database (Denmark)

    Arslanagic, Samel; Breinbjerg, Olav

    2008-01-01

    It has been shown that the sub-wavelength resonances of circular MTM cylinders also occur for polygonal MTM cylinders. This is the case for lossless and non-dispersive cylinders as well as lossy and dispersive cylinders. The sub-wavelength resonances are thus not limited to structures of canonical...

  9. Image registration in gastric emptying studies

    International Nuclear Information System (INIS)

    Shuter, B.; Cooper, R.G.

    1998-01-01

    Full text: We have previously shown that image registration, based upon a two-dimensional cross-correlation (CC) of logarithmic Laplacian images (LLI), corrected motion in biliary studies in up to 90% of cases with minimal artifact. We have now applied the same technique to gastric emptying studies (GES). GES were acquired on an LFOV gamma camera over a two-hour period as 20-26 pairs of anterior-posterior frames (30 second duration and 64 x 64 matrix) for both solid and liquid components. All images were manually registered so that the solid contents of the stomach lay within an operator-drawn ROI. The anterior images of the solid component for 30 randomly selected patients were subjected to further image registration using CC of LLI, CC of raw images (Rl) (a common approach to image registration) and CC of Laplacian images (Ll). All images were aligned to the third image of the study, on which an ROI was drawn to outline the stomach. The number of images in which stomach counts appeared outside this ROI were tallied, in the original and all re-registered studies. Maximum displacements in X/Y position between images of studies registered by the LLI and Rl methods were also computed to directly compare positional accuracy. Stomachs partially exceeded the limits of the ROI in 27, 9, 53 and 54 frames (total of 710) in the original, LLI, Rl and Ll studies respectively. There were 4, 1, 6 and 7 studies with misregistered stomachs on more than 2 frames. Frames in seven Rl studies differed from the LLI studies in ) X/Y position by 3 pixels or more. Cross-correlation using LLI was the only method which improved upon the original manual registration. The Rl and Ll methods increased the number of misregistered frames. We conclude that in gastric emptying studies, as in biliary studies, object tracking by CC of LLI is the method of choice for image registration

  10. Effect of leaving milk trucks empty and idle for 6 h between raw milk loads.

    Science.gov (United States)

    Kuhn, Eva; Meunier-Goddik, Lisbeth; Waite-Cusic, Joy G

    2018-02-01

    The US Pasteurized Milk Ordinance (PMO) allows milk tanker trucks to be used repeatedly for 24 h before mandatory clean-in-place cleaning, but no specifications are given for the length of time a tanker can be empty between loads. We defined a worst-case hauling scenario as a hauling vessel left empty and dirty (idle) for extended periods between loads, especially in warm weather. Initial studies were conducted using 5-gallon milk cans (pilot-scale) as a proof-of-concept and to demonstrate that extended idle time intervals could contribute to compromised raw milk quality. Based on pilot-scale results, a commercial hauling study was conducted through partnership with a Pacific Northwest dairy co-op to verify that extended idle times of 6 h between loads have minimal influence on the microbiological populations and enzyme activity in subsequent loads of milk. Milk cans were used to haul raw milk (load 1), emptied, incubated at 30°C for 3, 6, 10, and 20 h, and refilled with commercially pasteurized whole milk (load 2) to measure cross-contamination. For the commercial-scale study, a single tanker was filled with milk from a farm known to have poorer quality milk (farm A, load 1), emptied, and refilled immediately (0 h) or after a delay (6 h) with milk from a farm known to have superior quality milk (farm B, load 2). In both experiments, milk samples were obtained from each farm's bulk tank and from the milk can or tanker before unloading. Each sample was microbiologically assessed for standard plate count (SPC), lactic acid bacteria (LAB), and coliform counts. Selected isolates were assessed for lipolytic and proteolytic activity using spirit blue agar and skim milk agar, respectively. The pilot-scale experiment effectively demonstrated that extended periods of idle (>3 h) of soiled hauling vessels can significantly affect the microbiological quality of raw milk in subsequent loads; however, extended idle times of 6 h or less would not measurably compromise milk

  11. SU-E-T-579: Impact of Cylinder Size in High-Dose Rate Brachytherapy (HDRBT) for Primary Cancer in the Vagina

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, H; Gopalakrishnan, M; Lee, P; Sathiaseelan, V [Department of Radiation Oncology, Northwestern Memorial Hospital, Chicago, IL (United States)

    2014-06-01

    Purpose: To evaluate the dosimetric impact of cylinder size in high dose rate Brachytherapy for primary vaginal cancers. Methods: Patients treated with HDR vaginal vault radiation in a list of cylinders ranging from 2.5 to 4 cm in diameter at 0.5 cm increment were analyzed. All patients’ doses were prescribed at the 0.5 cm from the vaginal surface with different treatment lengths. A series of reference points were created to optimize the dose distribution. The fraction dose was 5.5 Gy, the treatment was repeated for 4 times in two weeks. A cylinder volume was contoured in each case according to the prescribed treatment length, and then expanded to 5 mm to get a volume Cylinder-5mm-exp. A volume of PTV-Eval was obtained by subtracting the cylinder volume from the Cylinder-5mm-exp. The shell volume, PTV-Eval serves as the target volume for dosimetric evaluation. Results: DVH curves and average doses of PTV-Eval were obtained. Our results indicated that the DVH curves shifted toward higher dose side when larger cylinder was used instead of smaller ones. When 3.0 cm cylinder was used instead of 2.5 cm, for 3.0 cm treatment length, the average dose only increased 1%, from 790 to 799 cGy. However, the average doses for 3.5 and 4 cm cylinders respectively are 932 and 1137 cGy at the same treatment length. For 5.0 cm treatment length, the average dose is 741 cGy for 2.5 cm cylinder, and 859 cGy for 3 cm cylinder. Conclusion: Our data analysis suggests that for the vaginal intracavitary HDRBT, the average dose is at least 35% larger than the prescribed dose in the studied cases; the size of the cylinder will impact the dose delivered to the target volume. The cylinder with bigger diameter tends to deliver larger average dose to the PTV-Eval.

  12. Cellobiohydrolase B of Aspergillus niger over-expressed in Pichia pastoris stimulates hydrolysis of oil palm empty fruit bunches.

    Science.gov (United States)

    Woon, James Sy-Keen; Mackeen, Mukram M; Illias, Rosli M; Mahadi, Nor M; Broughton, William J; Murad, Abdul Munir Abdul; Abu Bakar, Farah Diba

    2017-01-01

    Aspergillus niger , along with many other lignocellulolytic fungi, has been widely used as a commercial workhorse for cellulase production. A fungal cellulase system generally includes three major classes of enzymes i.e., β-glucosidases, endoglucanases and cellobiohydrolases. Cellobiohydrolases (CBH) are vital to the degradation of crystalline cellulose present in lignocellulosic biomass. However, A. niger naturally secretes low levels of CBH. Hence, recombinant production of A. niger CBH is desirable to increase CBH production yield and also to allow biochemical characterisation of the recombinant CBH from A. niger . In this study, the gene encoding a cellobiohydrolase B ( cbh B) from A. niger ATCC 10574 was cloned and expressed in the methylotrophic yeast Pichia pastoris X-33. The recombinant CBHB was purified and characterised to study its biochemical and kinetic characteristics. To evaluate the potential of CBHB in assisting biomass conversion, CBHB was supplemented into a commercial cellulase preparation (Cellic ® CTec2) and was used to hydrolyse oil palm empty fruit bunch (OPEFB), one of the most abundant lignocellulosic waste from the palm oil industry. To attain maximum saccharification, enzyme loadings were optimised by response surface methodology and the optimum point was validated experimentally. Hydrolysed OPEFB samples were analysed using attenuated total reflectance FTIR spectroscopy (ATR-FTIR) to screen for any compositional changes upon enzymatic treatment. Recombinant CBHB was over-expressed as a hyperglycosylated protein attached to N -glycans. CBHB was enzymatically active towards soluble substrates such as 4-methylumbelliferyl-β-D-cellobioside (MUC), p -nitrophenyl-cellobioside ( p NPC) and p -nitrophenyl-cellobiotrioside ( p NPG3) but was not active towards crystalline substrates like Avicel ® and Sigmacell cellulose. Characterisation of purified CBHB using MUC as the model substrate revealed that optimum catalysis occurred at 50 °C and

  13. SparseLeap: Efficient Empty Space Skipping for Large-Scale Volume Rendering

    KAUST Repository

    Hadwiger, Markus; Al-Awami, Ali K.; Beyer, Johanna; Agus, Marco; Pfister, Hanspeter

    2017-01-01

    Recent advances in data acquisition produce volume data of very high resolution and large size, such as terabyte-sized microscopy volumes. These data often contain many fine and intricate structures, which pose huge challenges for volume rendering, and make it particularly important to efficiently skip empty space. This paper addresses two major challenges: (1) The complexity of large volumes containing fine structures often leads to highly fragmented space subdivisions that make empty regions hard to skip efficiently. (2) The classification of space into empty and non-empty regions changes frequently, because the user or the evaluation of an interactive query activate a different set of objects, which makes it unfeasible to pre-compute a well-adapted space subdivision. We describe the novel SparseLeap method for efficient empty space skipping in very large volumes, even around fine structures. The main performance characteristic of SparseLeap is that it moves the major cost of empty space skipping out of the ray-casting stage. We achieve this via a hybrid strategy that balances the computational load between determining empty ray segments in a rasterization (object-order) stage, and sampling non-empty volume data in the ray-casting (image-order) stage. Before ray-casting, we exploit the fast hardware rasterization of GPUs to create a ray segment list for each pixel, which identifies non-empty regions along the ray. The ray-casting stage then leaps over empty space without hierarchy traversal. Ray segment lists are created by rasterizing a set of fine-grained, view-independent bounding boxes. Frame coherence is exploited by re-using the same bounding boxes unless the set of active objects changes. We show that SparseLeap scales better to large, sparse data than standard octree empty space skipping.

  14. SparseLeap: Efficient Empty Space Skipping for Large-Scale Volume Rendering

    KAUST Repository

    Hadwiger, Markus

    2017-08-28

    Recent advances in data acquisition produce volume data of very high resolution and large size, such as terabyte-sized microscopy volumes. These data often contain many fine and intricate structures, which pose huge challenges for volume rendering, and make it particularly important to efficiently skip empty space. This paper addresses two major challenges: (1) The complexity of large volumes containing fine structures often leads to highly fragmented space subdivisions that make empty regions hard to skip efficiently. (2) The classification of space into empty and non-empty regions changes frequently, because the user or the evaluation of an interactive query activate a different set of objects, which makes it unfeasible to pre-compute a well-adapted space subdivision. We describe the novel SparseLeap method for efficient empty space skipping in very large volumes, even around fine structures. The main performance characteristic of SparseLeap is that it moves the major cost of empty space skipping out of the ray-casting stage. We achieve this via a hybrid strategy that balances the computational load between determining empty ray segments in a rasterization (object-order) stage, and sampling non-empty volume data in the ray-casting (image-order) stage. Before ray-casting, we exploit the fast hardware rasterization of GPUs to create a ray segment list for each pixel, which identifies non-empty regions along the ray. The ray-casting stage then leaps over empty space without hierarchy traversal. Ray segment lists are created by rasterizing a set of fine-grained, view-independent bounding boxes. Frame coherence is exploited by re-using the same bounding boxes unless the set of active objects changes. We show that SparseLeap scales better to large, sparse data than standard octree empty space skipping.

  15. Observation of a relaxed plasma state in a quasi-infinite cylinder.

    Science.gov (United States)

    Gray, T; Brown, M R; Dandurand, D

    2013-02-22

    A helical relaxed plasma state is observed in a long cylindrical volume. The cylinder is long enough so that the predicted minimum energy state is a close approximation to the infinite cylinder solution. The plasma is injected at v ≥ 50 km/s by a coaxial magnetized plasma gun located at one end of the cylindrical volume. The relaxed state is rapidly attained in 1-2 axial Alfvén times after initiation of the plasma. Magnetic data are favorably compared with an analytical model. Magnetic data exhibit broadband fluctuations of the measured axial modes during the formation period. The broadband activity rapidly decays as the energy condenses into the lowest energy mode, which is in agreement with the minimum energy eigenstate of [Symbol: see text] × B = λB.

  16. Approximation by Cylinder Surfaces

    DEFF Research Database (Denmark)

    Randrup, Thomas

    1997-01-01

    We present a new method for approximation of a given surface by a cylinder surface. It is a constructive geometric method, leading to a monorail representation of the cylinder surface. By use of a weighted Gaussian image of the given surface, we determine a projection plane. In the orthogonal...

  17. Measurement of gastric emptying by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Furukawa, Akira; Kiyota, Keisuke; Takazakura, Ryutaro; Inokuchi, Hideto [Osaka Saiseikai Noe Hospital (Japan); Murata, Kiyoshi; Morita, Rikushi

    1996-02-01

    The purpose of the study was to establish a new method of measuring gastric emptying using MR imaging in human. Gastric emptying was measured in 6 healthy male volunteers aged from 28 to 43 years, using MR imaging and RI. The measurements were performed after the oral administration of liquid meal containing glucose, protein and fat. The MR imaging was performed with 0.5T superconducting magnet machine, and consecutive 12 transaxial T1 weighted spin echo images (TR/TE=300/17) of the upper abdomen were recorded every 10 minutes for more than 1 hour. Gastric emptying curves and their T1/2 values obtained by MR imaging and RI method were correlated well in 5 of 6 cases. We concluded that a non-invasive and radiation free method using MR imaging was proved to be a useful tool for measuring gastric emptying. (author).

  18. Empty tracks optimization based on Z-Map model

    Science.gov (United States)

    Liu, Le; Yan, Guangrong; Wang, Zaijun; Zang, Genao

    2017-12-01

    For parts with many features, there are more empty tracks during machining. If these tracks are not optimized, the machining efficiency will be seriously affected. In this paper, the characteristics of the empty tracks are studied in detail. Combining with the existing optimization algorithm, a new tracks optimization method based on Z-Map model is proposed. In this method, the tool tracks are divided into the unit processing section, and then the Z-Map model simulation technique is used to analyze the order constraint between the unit segments. The empty stroke optimization problem is transformed into the TSP with sequential constraints, and then through the genetic algorithm solves the established TSP problem. This kind of optimization method can not only optimize the simple structural parts, but also optimize the complex structural parts, so as to effectively plan the empty tracks and greatly improve the processing efficiency.

  19. The Empty Seashell

    DEFF Research Database (Denmark)

    Bubandt, Nils

    The Empty Seashell explores what it is like to live in a world where cannibal witches are undeniably real, yet too ephemeral and contradictory to be an object of belief. In a book based on more than three years of fieldwork between 1991 and 2011, Nils Bubandt argues that cannibal witches for people...

  20. External scintigraphy in measuring rate of gastric emptying in beagles

    Energy Technology Data Exchange (ETDEWEB)

    Theodorakis, M.C.

    1980-07-01

    The application of external scintigraphy and preparation of a new radiopharmaceutical agent for the investigation of the rate and pattern of gastric emptying in beagles and for the visualization of segments of the intestines have been described. 99mTc-labeled triethylenetetramine-polystyrene resin was mixed in a test meal and was administered to the animal. The gastric emptying rate of the beagle was evaluated by serially recording the gastric radioactivity by means of a scintillation camera. The experimental data indicate that the pattern of gastric emptying of beagles during the first 60 min was monoexponential and the gastric emptying half time was 1.3 h. The usefulness of external scintigraphy as a noninvasive method for determining the gastric emptying rates and for visualizing segments of GI tract in animals has been demonstrated.

  1. Automated analysis of gastric emptying

    International Nuclear Information System (INIS)

    Abutaleb, A.; Frey, D.; Spicer, K.; Spivey, M.; Buckles, D.

    1986-01-01

    The authors devised a novel method to automate the analysis of nuclear gastric emptying studies. Many previous methods have been used to measure gastric emptying but, are cumbersome and require continuing interference by the operator to use. Two specific problems that occur are related to patient movement between images and changes in the location of the radioactive material within the stomach. Their method can be used with either dual or single phase studies. For dual phase studies the authors use In-111 labeled water and Tc-99MSC (Sulfur Colloid) labeled scrambled eggs. For single phase studies either the liquid or solid phase material is used

  2. Correlation between solid gastric emptying and endoscopy after silastic ring vertical gastroplasty

    International Nuclear Information System (INIS)

    Furtado, P.C.; Brunetto, S.Q.; Etchebehere, E.C.S.C.; Sansana, C.R.; Santos, A.O.; Lima, M.C.L.; Ramos, C.D.; Camargo, E.E.; Pareja, J.C.

    2002-01-01

    Bariatric surgeries have been used in the treatment of obese patients. Silastic ring vertical gastroplasty (SRVG) consists of creating a gastric pouch which will lead to changes in the mechanism of digestion and to weight loss Aim: To determine the solid gastric emptying T1/2 in patients who underwent SRVG, and to correlate these findings with endoscopy, body mass index (BMI) and percent loss of excess body weight (PLEBW). Materials and Methods: Thirty six obese patients (30 women and 6 men, mean age 40.3 years) were submitted to SRVG. Endoscopy was performed 6 to 12 months after SRVG to classify the ring introduced into the neo stomach as tight, medium and large. Twelve to 18 months after SRVG the patients were submitted to scintigraphy and evaluation of BMI and PLEBW. Gastric emptying was performed with a solid meal which consisted of a cooked egg labeled with 99m Tc-microcolloid. Patients were placed in the upright position and acquisition was begun after ingestion of the radioactive meal. The gastric emptying T1/2 was calculated. Results: The T1/2 was 53.44 ± 40.26 minutes for patients with a tight ring (47.2% of the patient population); 68.03 ± 43.06 minutes for patients with a medium ring (22.2% of the patient population); and 23.06 ± 25.15 minutes for patients with a large ring (30.6% of the patient population). There was a significant correlation between T1/2 and endoscopic findings (p = 0.0482; ANOVA). Within 18 months after SRVG, patients showed BMI = 32.48 ± 7.51 and PLEBW = 77.41 ± 21.22 %. Statistical analyses showed that there was a tendency towards a direct correlation between T1/2 and PLEBW (r = 0.46; p 0.0045) and a tendency towards an inverse correlation with the BMI (r -0.48; p=0.0028). Conclusions: Despite the significant correlation between T1/2 and the endoscopic, BMI and PLEBW findings, this method was unable to differentiate the ring sizes, probably because endoscopy was performed at least 6 months prior to the gastric emptying study

  3. Scintigraphic test of gastric emptying and motility: preliminary results in patients with chronic gastritis

    International Nuclear Information System (INIS)

    Hausmann, T.; Mueller-Schauenburg, W.; Goeke, M.; Luebeck, M.; Gratz, K.F.; Meier, P.; Manns, M.; Hundeshagen, H.

    1995-01-01

    To record gastric peristalsis using a conventional scintigraphic gastric emptying test the frame rate was increased to 1 frame per 3 s at 10, 30, and 50 min postprandially. The gastric contraction frequency was obtained from the first harmonic of a Fourier transform of a gastric region of interest (ROI) curve. The propagation of gastric contractions was better revealed from computed functional images of the phase and amplitude distribution as compared with the multiple scintigraphic images. The maximal count-rate changes per pixel were calculated as an estimate of the most prominent regional contractile activity of the gastric wall. Among 12 patients with chronic gastritis the group with more severe dyspeptic complaints (n = 6) had significantly higher count-rate changes per pixel when compared with the group with minor complaints (20.0, 21.1 and 14.2 vs 12.9, 12.0, and 10.4 counts/pixel X s at 10, 30, and 50 min. respectively; p < 0.05). The mean half-times of gastric emptying (61, SD 11 vs 54, SD 13 min) and the mean gastric contraction frequencies (2.99, SD 0.19; 3.09, SD 0.33; 3.07, SD 0.10 vs 3.15, SD 0.15; 3.17, SD 0.13; 3.23, SD 0.20 cycles/min at 10, 30, and 50 min, respectively) did not show significant differences between both groups. Our preliminary results agree with the hypothesis of the occurrence of more powerful, nonexpulsive gastric-wall contractions in patients with more severe dyspeptic complaints. Hence, additional quantification of gastric motility allowed a more detailed evaluation of gastric-motor-activity disorders that were for so long not accessible to conventional gastric-emptying tests. (orig.)

  4. Scintigraphic test of gastric emptying and motility: preliminary results in patients with chronic gastritis

    Energy Technology Data Exchange (ETDEWEB)

    Hausmann, T. [Abt. Nuklearmedizin und Spezielle Biophysik, Medizinische Hochschule Hannover (Germany); Mueller-Schauenburg, W. [Abt. Nuklearmedizin, Univ. Tuebingen (Germany); Goeke, M. [Abt. Gastroenterologie und Hepatologie, Medizinische Hochschule Hannover (Germany); Luebeck, M. [Abt. Nuklearmedizin, Univ.-Krankenhaus Eppendorf, Hamburg (Germany); Gratz, K.F. [Abt. Nuklearmedizin und Spezielle Biophysik, Medizinische Hochschule Hannover (Germany); Meier, P. [Abt. Gastroenterologie und Hepatologie, Medizinische Hochschule Hannover (Germany); Manns, M. [Abt. Gastroenterologie und Hepatologie, Medizinische Hochschule Hannover (Germany); Hundeshagen, H. [Abt. Nuklearmedizin und Spezielle Biophysik, Medizinische Hochschule Hannover (Germany)

    1995-11-01

    To record gastric peristalsis using a conventional scintigraphic gastric emptying test the frame rate was increased to 1 frame per 3 s at 10, 30, and 50 min postprandially. The gastric contraction frequency was obtained from the first harmonic of a Fourier transform of a gastric region of interest (ROI) curve. The propagation of gastric contractions was better revealed from computed functional images of the phase and amplitude distribution as compared with the multiple scintigraphic images. The maximal count-rate changes per pixel were calculated as an estimate of the most prominent regional contractile activity of the gastric wall. Among 12 patients with chronic gastritis the group with more severe dyspeptic complaints (n = 6) had significantly higher count-rate changes per pixel when compared with the group with minor complaints (20.0, 21.1 and 14.2 vs 12.9, 12.0, and 10.4 counts/pixel X s at 10, 30, and 50 min. respectively; p < 0.05). The mean half-times of gastric emptying (61, SD 11 vs 54, SD 13 min) and the mean gastric contraction frequencies (2.99, SD 0.19; 3.09, SD 0.33; 3.07, SD 0.10 vs 3.15, SD 0.15; 3.17, SD 0.13; 3.23, SD 0.20 cycles/min at 10, 30, and 50 min, respectively) did not show significant differences between both groups. Our preliminary results agree with the hypothesis of the occurrence of more powerful, nonexpulsive gastric-wall contractions in patients with more severe dyspeptic complaints. Hence, additional quantification of gastric motility allowed a more detailed evaluation of gastric-motor-activity disorders that were for so long not accessible to conventional gastric-emptying tests. (orig.)

  5. 30 CFR 36.24 - Engine joints.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Engine joints. 36.24 Section 36.24 Mineral... Construction and Design Requirements § 36.24 Engine joints. (a) Cylinder head. The joint between the cylinder head and block of the engine shall be fitted with a metal or metal-clad gasket satisfactory to MSHA...

  6. Theoretical and experimental stress analyses of ORNL thin-shell cylinder-to-cylinder model 2

    International Nuclear Information System (INIS)

    Gwaltney, R.C.; Bolt, S.E.; Bryson, J.W.

    1975-10-01

    Model 2 in a series of four thin-shell cylinder-to-cylinder models was tested, and the experimentally determined elastic stress distributions were compared with theoretical predictions obtained from a thin-shell finite-element analysis. Both the cylinder and the nozzle of model 2 had outside diameters of 10 in., giving a d 0 /D 0 ratio of 1.0, and both had outside diameter/thickness ratios of 100. Sixteen separate loading cases in which one end of the cylinder was rigidly held were analyzed. An internal pressure loading, three mutually perpendicular force components, and three mutually perpendicular moment components were individually applied at the free end of the cylinder and at the end of the nozzle. In addition to these 13 loadings, 3 additional loads were applied to the nozzle (in-plane bending moment, out-of-plane bending moment, and axial force) with the free end of the cylinder restrained. The experimental stress distributions for each of the 16 loadings were obtained using 152 three-gage strain rosettes located on the inner and outer surfaces. All the 16 loading cases were also analyzed theoretically using a finite-element shell analysis. The analysis used flat-plate elements and considered five degrees of freedom per node in the final assembled equations. The comparisons between theory and experiment show reasonably good general agreement, and it is felt that the analysis would be satisfactory for most engineering purposes. (auth)

  7. Inhibitory effect of ramosetron on corticotropin releasing factor- and soybean oil-induced delays in gastric emptying in rats.

    Science.gov (United States)

    Hirata, Takuya; Keto, Yoshihiro; Yamano, Mayumi; Yokoyama, Toshihide; Sengoku, Takanori; Seki, Nobuo

    2012-09-01

    Symptoms of functional dyspepsia (FD) are highly prevalent in patients with irritable bowel syndrome (IBS). However, the effects of therapeutic agents for IBS on the pathophysiology of FD are unclear. In this study, therefore, we examined the effects of ramosetron, a serotonin 5-HT(3) receptor antagonist, on corticotropin releasing factor (CRF)- and soybean oil-induced delays in gastric emptying of rats, in comparison with anti-diarrheal agent and spasmolytics. The involvement of 5-HT and the 5-HT(3) receptor in delayed gastric emptying was also evaluated. Corticotropin releasing factor was administered intravenously to rats 10min before oral administration of 0.05% phenol red solution, and the amount remaining in the stomach was measured after 30min. Soybean oil was administered orally with glass beads, and the number of residual beads in the stomach was counted 1h later. Both CRF and soybean oil inhibited gastric emptying dose-dependently. Ramosetron and itopride, a gastro-prokinetic agent, significantly reduced both CRF- and soybean oil-induced delays in gastric emptying, while an anti-diarrheal agent and spasmolytics aggravated them. Pretreatment with p-chlorophenylalanine for 2days to reduced the synthesis of endogenous 5-HT diminished the effects of both CRF and soybean oil on gastric emptying. A 5-HT(3) receptor agonist m-chlorophenylbiguanide suppressed gastric emptying of both phenol red and glass beads, and those effects were reversed by ramosetron. These results suggest that CRF and soybean oil suppress gastric emptying in rats by activating 5-HT(3) receptors, and that by antagonizing these receptors, ramosetron may ameliorate symptoms of FD in clinical settings. © 2012 Journal of Gastroenterology and Hepatology Foundation and Blackwell Publishing Asia Pty Ltd.

  8. Pressure cylinders under fire condition

    Directory of Open Access Journals (Sweden)

    Jan Hora

    2016-03-01

    Full Text Available The presence of pressure cylinders under fire conditions significantly increases the risk rate for the intervening persons. It is considerably problematic to predict the pressure cylinders behaviour during heat exposition, its destruction progress and possible following explosion of the produced air–gas mixture because pressure cylinders and its environment generate a highly complicated dynamic system during an uncontrolled destruction. The large scale tests carried out by the Pilsen Fire and Rescue Department and the Rapid Response Unit of the Czech Republic Police in October 2012 and in May 2014 in the Military area Brdy and in the area of the former Lachema factory in Kaznějov had several objectives, namely, to record, qualify and quantify some of the aspects of an uncontrolled heat destruction procedure of an exposed pressure cylinder in an enclosed space and to qualify and describe the process of a controlled destruction of a pressure cylinder by shooting through it including basic tactical concepts. The article describes the experiments that were carried out.

  9. Effect of drink carbohydrate content on postexercise gastric emptying, rehydration, and the calculation of net fluid balance.

    Science.gov (United States)

    Clayton, David J; Evans, Gethin H; James, Lewis J

    2014-02-01

    The purpose of this study was to examine the gastric emptying and rehydration effects of hypotonic and hypertonic glucose-electrolyte drinks after exercise-induced dehydration. Eight healthy males lost ~1.8% body mass by intermittent cycling and rehydrated (150% of body mass loss) with a hypotonic 2% (2% trial) or a hypertonic 10% (10% trial) glucose-electrolyte drink over 60 min. Blood and urine samples were taken at preexercise, postexercise, and 60, 120, 180, and 240 min postexercise. Gastric and test drink volume were determined 15, 30, 45, 60, 90, and 120 min postexercise. At the end of the gastric sampling period 0.3% (2% trial) and 42.1% (10% trial; p rehydration drink might be mediated by a slower rate of gastric emptying, but the slow gastric emptying of such solutions makes rehydration efficiency difficult to determine in the hours immediately after drinking, compromising the calculation of net fluid balance.

  10. Empty sella syndrome

    International Nuclear Information System (INIS)

    Park, Chang Yoon

    1973-01-01

    The enlarged sella was encountered ordinarily as intrasellar lesion such as pituitary tumor or secondary increased intracranial pressure without certain mechanism. 1951 Busch discovered from his extensive autopsy cases that defects or incomplete attachment of diaphragm sella brings sella enlargement either slightly or moderately enlarged sella with subarachnoid extension. Toennis et al in 1955 discussed enlarged sella due to via infundibular defects or loosely attached stalk area of diaphragm sella from secondary increased intracranial pressure. Du Boulay and others differentiate the entity of none tumor origin of sella enlargement either from raised intracranial pressure or parasella changes, Hence, 'empty sella' was loosely used terminology. We observed following three representative cases in various empty sella syndrome. Case 1: air extended into the sella by pneumoencephalogram. Case 2: chiasma recess herniated into the sella secondary to dilated third ventricle from right thalamic tumor extension. Case 3: enlarged sella firstly mimic intrasella tumor but found intrasella fluid of cerebro-spinal content of extended subarchnoid space into sella. Above changes readily observed by pneumoencephalogram and other means

  11. Evaluation of Flow Accelerated Corrosion of Carbon Steel with Rotating Cylinder

    International Nuclear Information System (INIS)

    Park, Tae Jun; Lee, Eun Hee; Kim, Kyung Mo; Kim, Hong Pyo

    2012-01-01

    Flow accelerated corrosion (FAC) of the carbon steel piping in nuclear power plants (NPPs) has been major issue in nuclear industry. Rotating cylinder FAC test facility was designed and fabricated and then performance of the facility was evaluated. The facility is very simple in design and economic in fabrication and can be used in material and chemistry screening test. The facility is equipped with on line monitoring of pH, conductivity, dissolved oxygen(DO), and temperature. Fluid velocity is controlled with rotating speed of the cylinder with a test specimen. FAC test of SA106 Gr. B carbon steel under 4 m/s flow velocity was performed with the rotating cylinder at DO concentration of less than 1 ppb and of 1.3 ppm. Also a corrosion test of the carbon steel at static condition, that is at zero fluid velocity, of test specimen and solution was performed at pH from 8 to 10 for comparison with the FAC data. For corrosion test in static condition, the amount of non adherent corrosion product was almost constant at pH ranging from 8 to 10. But adherent corrosion product decreased with increasing pH. This trend is consistent with decrease of Fe solubility with an increase in pH. For FAC test with rotating cylinder FAC test facility, the amount of non adherent corrosion product was also almost same for both DO concentrations. The rotating cylinder FAC test facility will be further improved by redesigning rotating cylinder and FAC specimen geometry for future work

  12. Erythromycin antagonizes the deceleration of gastric emptying by glucagon-like peptide 1 and unmasks its insulinotropic effect in healthy subjects

    DEFF Research Database (Denmark)

    Meier, Juris J; Kemmeries, Guido; Holst, Jens Juul

    2005-01-01

    . On separate occasions, the prokinetic drugs metoclopramide (10 mg), domperidone (10 mg), cisapride (10 mg, all at -30 min per oral), or erythromycin (200 mg intravenously from -30 to -15 min) were administered in addition to GLP-1. A liquid test meal (50 g sucrose and 8% mixed amino acids in 400 ml......, we aimed to antagonize the deceleration of gastric emptying by GLP-1 to study its effects on insulin secretion after a meal. Nine healthy male volunteers (age 25 +/- 4 years, BMI 25.0 +/- 4.9 kg/m2) were studied with an infusion of GLP-1 (0.8 pmol.kg(-1).min(-1) from -30 to 240 min) or placebo...... technique. Statistical analyses were performed using repeated-measures ANOVA and Duncan's post hoc test. GLP-1 significantly decelerated the velocity of gastric emptying (P drugs used had no effect. Postprandial...

  13. Pulse Packet Stochastic Model for Gastric Emptying in the Fasted State: A Physiological Approach.

    Science.gov (United States)

    Talattof, Arjang; Amidon, Gordon L

    2018-03-05

    Fasted-state gastrointestinal (GI) fluid transit is typically represented as a first-order, deterministic process (averaged and viewed as a continuous approximation). It is, however, most likely a discrete process involving fluid packets interrupted by variable time periods of little to no fluid emptying. In this report we present a physiologically based pulsed-packet gastric fluid emptying model and evaluate it with respect to recent gastrointestinal fluid volume emptying results, published gastric emptying of various dosage forms, and gastric fluid emptying as a function of GI motility. We develop the mathematical model for gastric emptying of discrete volumes emptied during intermittent pulse times of variable lengths, defined as a function of gastric motility utilizing a Poisson point process with motility-dependent intensity. We compare the simulations with observed gastric emptying results. The discrete pulse-packet gastric volumetric emptying model is a more physiologically realistic mathematical model for gastric emptying and it accounts well for the average observed emptying rates and, importantly, encompasses the variability of of observed volume and dosage form emptying rates.

  14. Surface Morphology Diagram for Cylinder-Forming Block Copolymer Thin Films

    International Nuclear Information System (INIS)

    Zhang, Xiaohua; Berry, Brian C.; Yager, Kevin G.; Kim, Sangcheol; Jones, Ronald L.; Satija, Sushil; Pickel, Deanna L.; Douglas, Jack F.; Karim, Alamgir

    2008-01-01

    We investigate the effect of annealing temperature (T), film thickness (hf) on the surface morphology of flow coated films of a cylinder forming block copolymer, poly (styrene-block-methyl methacrylate) (PS-b-PMMA). Surface morphology transitions from a perpendicular to a parallel cylinder orientation with respect to the substrate with increasing hf are observed in these model 'frustrated-interaction' films where the substrate interaction is preferential for one of the blocks (PMMA) and nearly neutral for the other interface (polymer-air). In these films a transition occurs from cylinders oriented parallel to the substrate to a mixed or 'hybrid' state where the two orientations coexist followed by a transition to cylinders oriented perpendicularly to the polymer-air interface for larger hf. The characteristic values of hf defining these surface morphological transitions depend on T and we construct a surface morphology diagram as a function of hf and T. The surface morphology diagram is found to depend on the method of film formation (flow coated versus spun cast films) so non-equilibrium effects evidently have a large effect on the surface pattern morphology. In particular, the residual solvent within the film (quantified by neutron reflectivity measurements) in the context of physics of glass-formation can have a large effect on the surface morphology diagram

  15. Design of nested Halbach cylinder arrays for magnetic refrigeration applications

    Energy Technology Data Exchange (ETDEWEB)

    Trevizoli, Paulo V., E-mail: trevizoli@polo.ufsc.br; Lozano, Jaime A.; Peixer, Guilherme F.; Barbosa Jr, Jader R.

    2015-12-01

    We present an experimentally validated analytical procedure to design nested Halbach cylinder arrays for magnetic cooling applications. The procedure aims at maximizing the magnetic flux density variation in the core of the array for a given set of design parameters, namely the inner diameter of the internal magnet, the air gap between the magnet cylinders, the number of segments of each magnet and the remanent flux density of the Nd{sub 2}Fe{sub 14}B magnet grade. The design procedure was assisted and verified by 3-D numerical modeling using a commercial software package. An important aspect of the optimal design is to maintain an uniform axial distribution of the magnetic flux density in the region of the inner gap occupied by the active magnetocaloric regenerator. An optimal nested Halbach cylinder array was manufactured and experimentally evaluated for the magnetic flux density in the inner gap. The analytically calculated magnetic flux density variation agreed to within 5.6% with the experimental value for the center point of the magnet gap. - Highlights: • An analytical procedure to design nested Halbach cylinder arrays is proposed. • An optimal magnet configuration was built based on the analytical procedure. • The procedure was validated with 3D COMSOL simulations and experimental data.

  16. Multiple Cylinder Free-Piston Stirling Machinery

    Science.gov (United States)

    Berchowitz, David M.; Kwon, Yong-Rak

    In order to improve the specific power of piston-cylinder type machinery, there is a point in capacity or power where an advantage accrues with increasing number of piston-cylinder assemblies. In the case of Stirling machinery where primary energy is transferred across the casing wall of the machine, this consideration is even more important. This is due primarily to the difference in scaling of basic power and the required heat transfer. Heat transfer is found to be progressively limited as the size of the machine increases. Multiple cylinder machines tend to preserve the surface area to volume ratio at more favorable levels. In addition, the spring effect of the working gas in the so-called alpha configuration is often sufficient to provide a high frequency resonance point that improves the specific power. There are a number of possible multiple cylinder configurations. The simplest is an opposed pair of piston-displacer machines (beta configuration). A three-cylinder machine requires stepped pistons to obtain proper volume phase relationships. Four to six cylinder configurations are also possible. A small demonstrator inline four cylinder alpha machine has been built to demonstrate both cooling operation and power generation. Data from this machine verifies theoretical expectations and is used to extrapolate the performance of future machines. Vibration levels are discussed and it is argued that some multiple cylinder machines have no linear component to the casing vibration but may have a nutating couple. Example applications are discussed ranging from general purpose coolers, computer cooling, exhaust heat power extraction and some high power engines.

  17. Natural convective heat transfer from square cylinder

    Energy Technology Data Exchange (ETDEWEB)

    Novomestský, Marcel, E-mail: marcel.novomestsky@fstroj.uniza.sk; Smatanová, Helena, E-mail: helena.smatanova@fstroj.uniza.sk; Kapjor, Andrej, E-mail: andrej.kapjor@fstroj.uniza.sk [University of Žilina, Faculty of Mechanical Engineering, Department of Power Engineering, Univerzitná 1, 010 26 Žilina (Slovakia)

    2016-06-30

    This article is concerned with natural convective heat transfer from square cylinder mounted on a plane adiabatic base, the cylinders having an exposed cylinder surface according to different horizontal angle. The cylinder receives heat from a radiating heater which results in a buoyant flow. There are many industrial applications, including refrigeration, ventilation and the cooling of electrical components, for which the present study may be applicable.

  18. Investigation of breached depleted UF{sub 6} cylinders

    Energy Technology Data Exchange (ETDEWEB)

    DeVan, J.H. [Martin Marietta Energy Systems, Inc., Oak Ridge, TN (United States)

    1991-12-31

    In June 1990, during a three-site inspection of cylinders being used for long-term storage of solid depleted UF{sub 6}, two 14-ton cylinders at Portsmouth, Ohio, were discovered with holes in the barrel section of the cylinders. An investigation team was immediately formed to determine the cause of the failures and their impact on future storage procedures and to recommend corrective actions. Subsequent investigation showed that the failures most probably resulted from mechanical damage that occurred at the time that the cylinders had been placed in the storage yard. In both cylinders evidence pointed to the impact of a lifting lug of an adjacent cylinder near the front stiffening ring, where deflection of the cylinder could occur only by tearing the cylinder. The impacts appear to have punctured the cylinders and thereby set up corrosion processes that greatly extended the openings in the wall and obliterated the original crack. Fortunately, the reaction products formed by this process were relatively protective and prevented any large-scale loss of uranium. The main factors that precipitated the failures were inadequate spacing between cylinders and deviations in the orientations of lifting lugs from their intended horizontal position. After reviewing the causes and effects of the failures, the team`s principal recommendation for remedial action concerned improved cylinder handling and inspection procedures. Design modifications and supplementary mechanical tests were also recommended to improve the cylinder containment integrity during the stacking operation.

  19. The hysterographic (empty bladder) view of the uterus

    International Nuclear Information System (INIS)

    Carroll, R.; Gombergh, R.

    1986-01-01

    Technical improvements in transducer design permit a direct coronal view of the uterus (''hysterographic view'') to be obtained with the bladder empty as a valuable complement to the usual US study of the pelvis with the bladder distended. Good visualization of the uterine cavity and wall is possible in 95% of cases. More than 50 cases of endometrial and myometrial pathology (polyps, cancers, submucous fibroids) with abnormalities inapparent on standard US scans have hysterographic and/or pathologic proof confirming the empty-bladder US-based diagnosis. If tubal visualization is not necessary, empty-bladder US may often avoid hysterography. It is also the best way to demonstrate IUD position

  20. The effect of isoperistaltic jejunal interposition upon gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Mackie, C.R.; Hall, A.W.; Clark, J.; Wisbey, M.; Baker, P.R.; Cuschieri, A.

    1981-12-01

    Ten patients with severe postgastrectomy-postvagotomy symptoms, all of whom had the features of vasomotor dumping, underwent gastric emptying studies, using a 300 milliliter meal of 15 per cent dextrose labeled with 99mTc-sulphur colloid. Studies were repeated two to 11 months following remedial operative treatment, using a 12.5 to 15.0 centimeter isoperistaltic jejunal interposition. Preoperatively, all patients had rapid gastric emptying with a typical biphasic pattern. Following isoperistaltic interposition, the rate of gastric emptying was similar to that found in control patients. Gastric emptying reverted to a more normal pattern but, as in the preoperative studies, was best described by a double exponential function, consisting of slow and fast components. Analysis of these particular functions suggests the manner in which isoperistaltic interposition modified the underlying disorder of gastric motility.

  1. An Unattended Verification Station for UF6 Cylinders: Development Status

    International Nuclear Information System (INIS)

    Smith, E.; McDonald, B.; Miller, K.; Garner, J.; March-Leuba, J.; Poland, R.

    2015-01-01

    In recent years, the International Atomic Energy Agency (IAEA) has pursued innovative techniques and an integrated suite of safeguards measures to address the verification challenges posed by advanced centrifuge technologies and the growth in separative work unit capacity at modern centrifuge enrichment plants. These measures would include permanently installed, unattended instruments capable of performing the routine and repetitive measurements previously performed by inspectors. Among the unattended instruments currently being explored by the IAEA is an Unattended Cylinder Verification Stations (UCVS) that could provide independent verification of the declared relative enrichment, U-235 mass and total uranium mass of all declared cylinders moving through the plant, as well as the application and verification of a ''Non-destructive Assay Fingerprint'' to preserve verification knowledge on the contents of each cylinder throughout its life in the facility. As IAEA's vision for a UCVS has evolved, Pacific Northwest National Laboratory (PNNL) and Los Alamos National Laboratory have been developing and testing candidate non-destructive assay (NDA) methods for inclusion in a UCVS. Modeling and multiple field campaigns have indicated that these methods are capable of assaying relative cylinder enrichment with a precision comparable to or substantially better than today's high-resolution handheld devices, without the need for manual wall-thickness corrections. In addition, the methods interrogate the full volume of the cylinder, thereby offering the IAEA a new capability to assay the absolute U-235 mass in the cylinder, and much-improved sensitivity to substituted or removed material. Building on this prior work, and under the auspices of the United States Support Programme to the IAEA, a UCVS field prototype is being developed and tested. This paper provides an overview of: a) hardware and software design of the prototypes, b) preparation

  2. Definition of a gastric emptying abnormality in patients with anorexia nervosa

    International Nuclear Information System (INIS)

    McCallum, R.W.; Grill, B.B.; Lange, R.; Planky, M.; Glass, E.E.; Greenfeld, D.G.

    1985-01-01

    Upper gastrointestinal symptoms may be prominent in anorexia nervosa. This study is an investigation of the gastric emptying of solid and liquid meal components in 16 female patients who met accepted psychiatric diagnostic criteria for anorexia nervosa. The results were compared with those of gastric emptying studies in 10 normal females of ideal body weight, 13 normal persons (12 males), and six patients with weight loss secondary to Crohn's disease with no psychiatric symptoms. A dual-isotope technique using chicken liver intracellularly labeled with technetium-/sup 99m/ (/sup 99m/Tc) bound to sulfur colloid as the solid-phase marker, and indium- 111 ( 111 In) -labeled water as the liquid-phase marker was used. In 13 of the 16 anorexia nervosa patients (80%), gastric emptying of solids was slower than the range in the two groups of normal subjects, and mean gastric emptying was significantly slower than in the weight-loss patients. Liquid emptying (water) in anorexia nervosa was normal and similar to the control groups studied. In 11 of the anorexia nervosa patients with delayed gastric emptying, intramuscular metoclopramide, 10 mg, significantly accelerated the mean gastric emptying from 60 through 120 min after the meal. The authors conclude that these data are consistent with an antral motility disturbance, either primary or secondary; and metoclopramide, a gastric prokinetic agent, accelerates (delayed) gastric emptying

  3. Acotiamide hydrochloride (Z-338) enhances gastric motility and emptying by inhibiting acetylcholinesterase activity in rats.

    Science.gov (United States)

    Kawachi, Masanao; Matsunaga, Yugo; Tanaka, Takao; Hori, Yuko; Ito, Katsunori; Nagahama, Kenji; Ozaki, Tomoko; Inoue, Naonori; Toda, Ryoko; Yoshii, Kazuyoshi; Hirayama, Masamichi; Kawabata, Yoshihiro; Takei, Mineo

    2011-09-01

    In clinical trials, acotiamide hydrochloride (acotiamide: Z-338) has been reported to be useful in the treatment of functional dyspepsia. Here, we investigated the effects of acotiamide on gastric contraction and emptying activities in rats in comparison with itopride hydrochloride (itopride) and mosapride citrate (mosapride). We also examined in vitro the compound's inhibitory effect on acetylcholinesterase (AChE) activity derived from rat stomach. In in vivo studies, acotiamide (30 and 100mg/kg s.c.) and itopride (100mg/kg s.c.) markedly enhanced normal gastric antral motility in rats. In gastric motility dysfunction models, acotiamide (100mg/kg s.c.) and itopride (100mg/kg s.c.) improved both gastric antral hypomotility and the delayed gastric emptying induced by clonidine, an α(2)-adrenoceptor agonist. In contrast, mosapride (10mg/kg s.c.) had no effect on these models. Like the AChE inhibitors itopride (30 mg/kg s.c.) and neostigmine (10 μg/kg s.c.), acotiamide (10mg/kg s.c.) also clearly enhanced gastric body contractions induced by electrical stimulation of the vagus, which were abolished by atropine and hexamethonium, whereas mosapride (3 and 10mg/kg s.c.) did not. In in vitro studies, acotiamide concentration-dependently inhibited rat stomach-derived AChE activity (IC(50)=2.3 μmol/l). In addition, stomach tissue concentrations of acotiamide after administration at 10mg/kg s.c. were sufficient to produce inhibition of AChE activity in rat stomach. These results suggest that acotiamide stimulates gastric motility and improves gastric motility dysfunction in rats by inhibiting AChE activity, and may suggest a role for acotiamide in improving gastric motility dysfunction in patients with functional dyspepsia. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Calories and gastric emptying: a regulatory capacity with implications for feeding.

    Science.gov (United States)

    McHugh, P R; Moran, T H

    1979-05-01

    Gastric emptying in four unanesthetized male Macaca mulatta was studied with the serial test meal method of Hunt and Spurrell. Liquid meals were infused into the stomach through a chronic indwelling Silastic cannula. Saline meals empty rapidly and exponentially. Doubling the volume of saline from 150 to 300 ml increased the emptying rate so that the half-life remained unchanged (15 min). The 150-ml glucose meals (0.05, 0.125, and 0.25 g/ml) emptied more slowly than saline, progressively more slowly with increasing concentrations (0.05--1.8, 0.125--0.78, and 0.25--0.37 ml/min) and linearly through most of their course. Doubling the volume of 0.125 g/ml-glucose meal did not change the rate of emptying. Converting grams of glucose to their caloric content, the emptying rate in kcal/min becomes constant (approx 0.4 kcal/min) in this range of concentrations. Isocaloric casein hydrolysate and medium-chain triglyceride oil meals at 0.5 kcal/ml empty at the same rate as glucose. The precision of this regulation is sufficient to give it a role in preabsorptive satiety and the control of caloric intake.

  5. Effect of bacterial lipopolysaccharide on gastric emptying of liquids in rats

    Directory of Open Access Journals (Sweden)

    E.F. Collares

    1997-02-01

    Full Text Available The objectives of the present investigation were 1 to study the effect of bacterial lipopolysaccharide (LPS on rat gastric emptying (GE and 2 to investigate a possible involvement of the vagus nerve in the gastric action of LPS. Endotoxin from E. coli (strain 055:B5 was administered sc, ip or iv to male Wistar rats (220-280 g body weight at a maximum dose of 50 µg/kg animal weight. Control animals received an equivalent volume of sterile saline solution. At a given time period after LPS administration, GE was evaluated by measuring gastric retention 10 min after the orogastric infusion of a test meal (2 ml/100 g animal weight, which consisted of 0.9% NaCl plus the marker phenol red (6 mg/dl. One group of animals was subjected to bilateral subdiaphragmatic vagotomy or sham operation 15 days before the test. A significant delay in GE of the test meal was observed 5 h after iv administration of the endotoxin at the dose of 50 µg/kg animal weight. The LPS-induced delay of GE was detected as early as 30 min and up to 8 h after endotoxin administration. The use of different doses of LPS ranging from 5 to 50 µg/kg animal weight showed that the alteration of GE was dose dependent. In addition, vagotomized animals receiving LPS displayed a GE that was not significantly different from that of the sham control group. However, a participation of the vagus nerve in LPS-induced delay in GE could not be clearly demonstrated by these experiments since vagotomy itself induced changes in this gastric parameter. The present study provides a suitable model for identifying the mechanisms underlying the effects of LPS on gastric emptying

  6. Stress analysis of cylinder to cylinder intersections

    International Nuclear Information System (INIS)

    Revesz, Z.

    1983-01-01

    Cylinder to cylinder intersections have numerous applications in the power industry from different piping junctions to pressure vessel nozzles. A specific purpose computer program has been installed at the author's establishment for finite element analysis of such geometries. Some of the experiences are presented giving a short overview of the analysis of unreinforced man-holes, demonstrating how a more economical design has been verified by analysis. The program installed has linear-elastic and elasto-plastic capabilities. Further, it is prepared for heat transfer analysis with subsequent thermal stress computation. An efficient pre- and post-processor has also been installed and enhanced by the author. The software used is at its present stage capable for problem definition with input data such as outside/ inside diameters, length and number of subdivisions. Similarly simple is the load definition and the graphic representation of the full output. (author)

  7. Validation of 13C-acetic acid breath test by measuring effects of loperamide, morphine, mosapride, and itopride on gastric emptying in mice.

    Science.gov (United States)

    Matsumoto, Kenjiro; Kimura, Hiroshi; Tashima, Kimihito; Uchida, Masayuki; Horie, Syunji

    2008-10-01

    Several methods are used to evaluate gastric motility in rodents, but they all have technical limitations. Recent technical developments enable a convenient method to evaluate gastric motility. The (13)C-acetic acid breath test in rodents is a non-invasive and repeatable method that can be used without physical restraints. The present study aimed to validate the (13)C-acetic acid breath test by measuring the effects of loperamide, morphine, mosapride, and itopride on gastric emptying in mice. Loperamide (1-10 mg/kg) and morphine (1.25-10 mg/kg) slowed gastric emptying and decreased the maximum concentration (C(max)) and area under the curve (AUC(90 min)) value in a dose-dependent manner. Mosapride (0.2-5 mg/kg) accelerated gastric emptying and increased C(max) value. Mosapride (20 mg/kg) did not accelerate gastric emptying on the (13)C-breath test. Itopride (30 mg/kg, per os) significantly accelerated gastric emptying compared with the vehicle group. In a comparison with the conventional phenol red test, there was a correlation between the C(max) value of breath test and gastric emptying (%) of phenol red tests in treatment with loperamide or mosapride. These results indicate that the (13)C-acetic acid breath test is an accurate, noninvasive, and simple method for monitoring gastric emptying in mice. This method is useful to assess the effect of drugs and gut function pharmacologically.

  8. Gastric emptying, CCK release, and satiety in weight-stable obese subjects

    NARCIS (Netherlands)

    Mathus-Vliegen, E. M. H.; van Ierland-van Leeuwen, M. L.; Roolker, W.

    2005-01-01

    Scintigraphic gastric emptying studies are far from conclusive in obesity. The aim was to investigate gastric emptying and CCK release in weight-stable obese subjects on their usual diet and to study the impact of factors known to determine gastric emptying. Patients entering a weight reduction

  9. Maintaining the power balance in an "empty network"

    NARCIS (Netherlands)

    Reza, M.; Dominguez, A.O.; Schavemaker, P.H.; Kling, W.L.

    2006-01-01

    This paper presents the concept of an empty network and shows how the power balance can be maintained in such a system. In this study, an empty network is defined as a power system in which no rotating mass is present; all generators are grid-connected via power electronic interfaces. One generator

  10. Effect of anxiety on the rate of gastric emptying of liquids.

    LENUS (Irish Health Repository)

    Lydon, A

    2012-02-03

    The efficacy of preoperative fasting is reduced in the presence of any factor which delays gastric emptying. We examined the association between anxiety and gastric emptying in adult patients undergoing elective surgery. Immediately before operation, 21 patients completed both a Spielberger state trait inventory (used to quantify current anxiety state (STAIs) and anxiety predisposition (STAIt)), and the Amsterdam preoperative anxiety and information scale (used to quantify anxiety and need for information). Gastric emptying was measured using the paracetamol absorption technique. Four to 10 weeks later, gastric emptying and STAI were measured again. Patients were more anxious before than after operation (STAIs = mean 35.4 (SD 10.9) and 25 (4.1), respectively; P = 0.0004). Neither anxiety state (P = 0.40) nor measures of anxiety relative to anxiety predisposition (P = 0.86) influenced gastric emptying (as measured by area under the paracetamol absorption-time curve). This contrasts with previous findings that anxiety in patients with low anxiety predisposition scores delays gastric emptying.

  11. Retardation of gastric emptying of solid food by secretin

    Energy Technology Data Exchange (ETDEWEB)

    Kleibeuker, J.H.; Beekhuis, H.; Piers, D.A.; Schaffalitzky de Muckadell, O.B.

    1988-01-01

    The effect of secretin at nearly physiologic plasma concentrations on the gastric emptying rate of solid food was studied in 12 healthy men. A /sup 99m/Tc colloid-labeled pancake was used as the test meal. The gastric emptying rate was measured during 1 h using a dual-headed gamma-camera, and was expressed as the half-time of the emptying curve. To prevent endogenous secretin release, 400 mg of cimetidine was given before the meal. Subjects were studied under three conditions: (1) during infusion of saline; (2) during continuous infusion of secretin, 6.6 pmol/kg.h; and (3) during three intermittent 10-min periods of secretin infusion, 7.6 pmol/kg.h during each period. Both continuous and intermittent infusion of secretin increased half-emptying time, by 133% and 55%, respectively. The plasma secretin concentration in condition 1 was 0.8 pM; plateau concentration in condition 2 was 9.8 pM; and integrated mean concentration in condition 3 was 4.8 pM. It is concluded that secretin at approximately physiologic plasma concentrations retards gastric emptying of solid food in humans.

  12. 25 CFR 542.30 - What is a Tier B gaming operation?

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false What is a Tier B gaming operation? 542.30 Section 542.30 Indians NATIONAL INDIAN GAMING COMMISSION, DEPARTMENT OF THE INTERIOR HUMAN SERVICES MINIMUM INTERNAL CONTROL STANDARDS § 542.30 What is a Tier B gaming operation? A Tier B gaming operation is one with gross...

  13. 49 CFR 180.209 - Requirements for requalification of specification cylinders.

    Science.gov (United States)

    2010-10-01

    ... industrial gas service. Requalification and Inspection of DOT-3AL Cylinders Made of Aluminum Alloy 6351-T6... corroding components; permitted mixtures of these gases (see § 173.301(d) of this subchapter); and permitted mixtures of these gases with up to 30 percent by volume of carbon dioxide, provided the gas has a dew point...

  14. Gastric emptying, glucose responses, and insulin secretion after a liquid test meal

    DEFF Research Database (Denmark)

    Willms, B; Werner, J; Holst, J J

    1996-01-01

    yr; body mass index, 30.0 +/- 5.2 kg/m2; hemoglobin A1c, 10.5 +/- 1.2%) were studied in the fasting state (plasma glucose, 11.1 +/- 1.1 mmol/L). A liquid meal of 400 mL containing 8% amino acids and 50 g sucrose (327 Kcal) was administered at time zero by a nasogastric tube. Gastric volume......The aim of the study was to investigate whether inhibition of gastric emptying of meals plays a role in the mechanism of the blood glucose-lowering action of glucagon-like peptide-1-(7-36) amide [GLP-1-(7-36) amide] in type 2 diabetes. Eight poorly controlled type 2 diabetic patients (age, 58 +/- 6...... to normal fasting values (5.4 +/- 0.7 mmol/L) within 3-4 h, whereas insulin was stimulated in most, but not all, patients, and glucagon remained at the basal level or was slightly suppressed. In conclusion, GLP-1-(7-36) amide inhibits gastric emptying in type 2 diabetic patients. Together...

  15. Gastric Emptying in Patients with Diabetes: Gastric Emptying Time, Retention Rate and Effect of Cisapride

    International Nuclear Information System (INIS)

    Chung, Byung Chun; Choi, Chung Il; Gwak, Dong Suck; Lee, Jae Tae; Lee, Kyu Bo; Kim, Bo Wan; Chung, Jun Mo

    1992-01-01

    Gastic emptying scan in diabetic patients is widely used to assess the degree of motility disturbance and the symptoms such as nausea, vomiting, bloating, abdominal pain and early gastric fullness which we can't find anatomic lesion by fiberoscopic or barium study. In order to determine the relationship among diabetic gastropathy, neropathy, retinopathy and disease duration, gastric emptying scan using 99m Tc-tin colloid labeled scramble egg in hamburger was performed in 10 healthy male controls and 50 diabetic patients which were subdivided to no neuropathy, peripheral neuropathy and autonomic neuropathy groups according to the degree of diabetic neuropathy and no retinopathy, background retinopathy and proliferative retinopathy groups according to the degree of diabetic retinopathy. After medication of cisapride for 2 weeks, we observed the presence of improvement of gastric motility in diabetics. The results were as following: 1) In controls, gastric emptying time (GET1/2) was 75 ± 13.6 min and 2 hour gastric retension rate(GRR2) was 32 ± 11.1%. 2) In diabetics, GET/2 was prolonged more than 2 hours and GRR2 was 58 ± 23.1%. According to degree of neuropathy, GET1/2 was prolonged more than 2 hours in all three groups and GRR2 was 54± 24.1% in no neuropathy group, 57 ± 24.3% in peripheral neuropathy group and 69 ± 24.6% in autonomic neuropathy group. According to degree of retinopathy, GET1/2 was 110 ± 23.4 min in no retinopathy group and prolonged more than 2 hours in other two groups and GRR2 was 45 ± 21.6% in no retinopathy group, 71 ± 19.7% in background retinopathy group and 73 ± 21.5% in proliferative retinopathy group. 3) After cisapride for 2 weeks, GET1/2 and GRR2 were improved as 90 ± 14.6 min and 40 ± 13.8% (initial GET1/2 and GRR2 were above 2 hours and 61 ± 15.4%). We can conclude from above findings that gastropathy in diabetic neuropathy suggesting main underlying factor in motility disorder. The degree of retinopathy and disease

  16. Gastric Emptying in Patients with Diabetes: Gastric Emptying Time, Retention Rate and Effect of Cisapride

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Byung Chun; Choi, Chung Il; Gwak, Dong Suck; Lee, Jae Tae; Lee, Kyu Bo; Kim, Bo Wan; Chung, Jun Mo [Kyungpook National University School of Medicine, Daegu (Korea, Republic of)

    1992-07-15

    Gastic emptying scan in diabetic patients is widely used to assess the degree of motility disturbance and the symptoms such as nausea, vomiting, bloating, abdominal pain and early gastric fullness which we can't find anatomic lesion by fiberoscopic or barium study. In order to determine the relationship among diabetic gastropathy, neropathy, retinopathy and disease duration, gastric emptying scan using {sup 99m}Tc-tin colloid labeled scramble egg in hamburger was performed in 10 healthy male controls and 50 diabetic patients which were subdivided to no neuropathy, peripheral neuropathy and autonomic neuropathy groups according to the degree of diabetic neuropathy and no retinopathy, background retinopathy and proliferative retinopathy groups according to the degree of diabetic retinopathy. After medication of cisapride for 2 weeks, we observed the presence of improvement of gastric motility in diabetics. The results were as following: 1) In controls, gastric emptying time (GET1/2) was 75 +- 13.6 min and 2 hour gastric retension rate(GRR2) was 32 +- 11.1%. 2) In diabetics, GET/2 was prolonged more than 2 hours and GRR2 was 58 +- 23.1%. According to degree of neuropathy, GET1/2 was prolonged more than 2 hours in all three groups and GRR2 was 54+- 24.1% in no neuropathy group, 57 +- 24.3% in peripheral neuropathy group and 69 +- 24.6% in autonomic neuropathy group. According to degree of retinopathy, GET1/2 was 110 +- 23.4 min in no retinopathy group and prolonged more than 2 hours in other two groups and GRR2 was 45 +- 21.6% in no retinopathy group, 71 +- 19.7% in background retinopathy group and 73 +- 21.5% in proliferative retinopathy group. 3) After cisapride for 2 weeks, GET1/2 and GRR2 were improved as 90 +- 14.6 min and 40 +- 13.8% (initial GET1/2 and GRR2 were above 2 hours and 61 +- 15.4%). We can conclude from above findings that gastropathy in diabetic neuropathy suggesting main underlying factor in motility disorder. The degree of retinopathy and

  17. A methodology to identify the intake charge cylinder-to-cylinder distribution in turbocharged direct injection Diesel engines

    Science.gov (United States)

    Luján, José M.; Galindo, José; Serrano, José R.; Pla, Benjamín

    2008-06-01

    Exhaust gas recirculation (EGR) is currently the most important NOx emission control system. During the last few years the EGR rate has increased progressively as pollutant emission regulations have become more restrictive. High EGR rate levels have given the effect of the unsuitable EGR and air distribution between cylinders away, which causes undesirable engine behavior. In this sense, the study of the EGR distribution between cylinders achieves high importance. However, despite the fact that the EGR is continuously under study, not many studies have been undertaken to approach its distribution between cylinders. In concordance with the aspects outlined before, the aim of this paper is to propose a methodology that permits us to identify the EGR cylinder-to-cylinder dispersion in a commercial engine. In order to achieve this objective, experimental tests have been combined with both one-dimensional and three-dimensional fluid dynamic models.

  18. Robust cylinder pressure estimation in heavy-duty diesel engines

    NARCIS (Netherlands)

    Kulah, S.; Forrai, A.; Rentmeester, F.; Donkers, T.; Willems, F.P.T.

    2017-01-01

    The robustness of a new single-cylinder pressure sensor concept is experimentally demonstrated on a six-cylinder heavy-duty diesel engine. Using a single-cylinder pressure sensor and a crank angle sensor, this single-cylinder pressure sensor concept estimates the in-cylinder pressure traces in the

  19. EmptyHeaded: A Relational Engine for Graph Processing.

    Science.gov (United States)

    Aberger, Christopher R; Tu, Susan; Olukotun, Kunle; Ré, Christopher

    2016-01-01

    There are two types of high-performance graph processing engines: low- and high-level engines. Low-level engines (Galois, PowerGraph, Snap) provide optimized data structures and computation models but require users to write low-level imperative code, hence ensuring that efficiency is the burden of the user. In high-level engines, users write in query languages like datalog (SociaLite) or SQL (Grail). High-level engines are easier to use but are orders of magnitude slower than the low-level graph engines. We present EmptyHeaded, a high-level engine that supports a rich datalog-like query language and achieves performance comparable to that of low-level engines. At the core of EmptyHeaded's design is a new class of join algorithms that satisfy strong theoretical guarantees but have thus far not achieved performance comparable to that of specialized graph processing engines. To achieve high performance, EmptyHeaded introduces a new join engine architecture, including a novel query optimizer and data layouts that leverage single-instruction multiple data (SIMD) parallelism. With this architecture, EmptyHeaded outperforms high-level approaches by up to three orders of magnitude on graph pattern queries, PageRank, and Single-Source Shortest Paths (SSSP) and is an order of magnitude faster than many low-level baselines. We validate that EmptyHeaded competes with the best-of-breed low-level engine (Galois), achieving comparable performance on PageRank and at most 3× worse performance on SSSP.

  20. Where are kids getting their empty calories? Stores, schools, and fast food restaurants each play an important role in empty calorie intake among US children in 2009-2010

    OpenAIRE

    Poti, Jennifer M.; Slining, Meghan M.; Popkin, Barry M.; Kenan, W.R.

    2013-01-01

    Consumption of empty calories, the sum of energy from added sugar and solid fat, exceeds recommendations, but little is known about where US children obtain these empty calories. The objectives of this study were to compare children's empty calorie consumption from retail food stores, schools, and fast food restaurants; to identify food groups that were top contributors of empty calories from each location; and to determine the location providing the majority of calories for these key food gr...

  1. HF DBD plasma actuators for reduction of cylinder noise in flow

    Science.gov (United States)

    Kopiev, V. F.; Kazansky, P. N.; Kopiev, V. A.; Moralev, I. A.; Zaytsev, M. Yu

    2017-11-01

    Surface high frequency dielectric barrier discharge (HF DBD) was used to reduce flow-induced noise, radiated by circular cylinder in cross flow. Effect of HF DBD actuators is studied for flow velocity up to 80 m s-1 (Reynolds numbers up to 2.18 · 105), corresponding to the typical aircraft landing approach speed. Noise measurements were performed by microphone array in anechoic chamber; averaged flow parameters were studied by particle image velocimetry (PIV). Actuator was powered by high-frequency voltage in hundreds kHz range in steady or modulated mode with the modulation frequency of 0.3-20 kHz (Strouhal number St of 0.4 to 20). It is demonstrated that upstream directed plasma actuators are able to reduce the vortex noise of a cylinder by 10 dB. Noise reduction is accompanied by significant reorganization of the wake behind a cylinder, decreasing both wake width and turbulence level. The physical mechanism related to broadband noise control by HF DBD actuator is also discussed.

  2. Aerodynamic loading on a cylinder behind an airfoil

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, H.J.; Huang, L.; Zhou, Y. [Hong Kong Polytechnic University, Department of Mechanical Engineering, Kowloon (Hong Kong)

    2005-05-01

    The interaction between the wake of a rotor blade and a downstream cylinder holds the key to the understanding and control of electronic cooling fan noise. In this paper, the aerodynamic characteristics of a circular cylinder are experimentally studied in the presence of an upstream NACA 4412 airfoil for the cylinder-diameter-based Reynolds numbers of Re{sub d}=2,100-20,000, and the airfoil chord-length-based Reynolds numbers of Re{sub c}=14,700-140,000. Lift and drag fluctuations on the cylinder, and the longitudinal velocity fluctuations of the flow behind the cylinder were measured simultaneously using a load cell and two hot wires, respectively. Data analysis shows that unsteady forces on the cylinder increase significantly in the presence of the airfoil wake. The dependence of the forces on two parameters is investigated, that is, the lateral distance (T) between the airfoil and the cylinder, and the Reynolds number. The forces decline quickly as Tincreases. For Re{sub c}<60,000, the vortices shed from the upstream airfoil make a major contribution to the unsteady forces on the cylinder compared to the vortex shedding from the cylinder itself. For Re{sub c}>60,000, no vortices are generated from the airfoil, and the fluctuating forces on the cylinder are caused by its own vortex shedding. (orig.)

  3. Gastric emptying and postprandial symptoms after Billroth II resection

    NARCIS (Netherlands)

    Smout, A. J.; Akkermans, L. M.; Roelofs, J. M.; Pasma, F. G.; Oei, H. Y.; Wittebol, P.

    1987-01-01

    Gastric emptying was studied in 18 symptomatic and 16 asymptomatic patients after Billroth II (BII) resection (without vagotomy) and the possible relationships between emptying and postprandial symptoms in these patients were assessed. The BII patients were compared with 20 nonoperated patients who

  4. Gallbladder emptying evaluation in calcific chronic pancreatitis using Tc-99m DISIDA scintigraphy

    International Nuclear Information System (INIS)

    Pedroso, Martha Regina A.; Cunha, Renata M.; Guarita, Dulce R.; Buchpieguel, Carlos A.; Mott, Carlos B.; Laudanna, Antonio Atilio

    1997-01-01

    The aim of this study was to analyze the gallbladder motor function in chronic pancreatitis (C) patients. Gallbladder emptying was evaluated in 11 patients, without and with addition of pancreatic extract and in ten controls. The results were compared and analyzed statistically. The ejection fraction (E F) of the gallbladder (GB) at 30, 45 and 60 minutes were calculated by using Tc-9 9 m DISIDA scintigraphy. The E F of GB at 60 minutes was significantly higher in the controls when compared to patients, although the results between patients were similar without and with addition of pancreatic extract. The results suggest that the delay in the GB emptying does not depend on the eventual alteration in the intestinal phase of the vesicular stimulation, but it probably results from a mechanic factor, which depends on the chronic pathological process located in the head of the pancreas. (author)

  5. Mechanical Integrity of Copper Canister Lid and Cylinder

    International Nuclear Information System (INIS)

    Karlsson, Marianne

    2002-01-01

    copper cylinder, in the region from the weld down to the level of the insert. Since these stresses appear on the outside of the canister, a damage tolerance analysis of this region should be performed. Tensile stresses appearing on the bottom of the lid are not likely to cause initiation of defects. Due to the magnitude of the stresses, the region should however be assessed regarding growth of existing defects. In a modified design, the lid is fitted in the copper cylinder with zero gap as opposed to the original design where there is a gap of 1 mm between the lid and cylinder. The peak tensile stresses caused by two critical load cases thus shift from the weld region to a region further down. Stresses in the order of magnitude of the yield strength do not appear until approximately 30 mm below the weld. This may be advantageous if the weld and the region in the vicinity of the weld are considered to be most critical as regards high tensile stresses

  6. Inner cylinder of the CMS vacuum tank.

    CERN Multimedia

    Patrice Loïez

    2002-01-01

    The vacuum tank of the CMS magnet system consists of inner and outer stainless-steel cylinders and houses the superconducting coil. The inner cylinder contains all the barrel sub-detectors, which it supports via a system of horizontal rails. The cylinder is pictured here in the vertical position on a yellow platform mounted on the ferris-wheel support structure. This will allow it to be pivoted and inserted into the outer cylinder already attached to the innermost ring of the barrel yoke.

  7. UF{sub 6} pressure excursions during cylinder heating

    Energy Technology Data Exchange (ETDEWEB)

    Brown, P.G. [Martin Marietta Energy Systems, Inc., Paducah, KY (United States)

    1991-12-31

    As liquid UF{sub 6} inside a cylinder changes from a liquid to a solid, it forms a porous solid which occupies approximately the same volume as that of the liquid before cooling. Simultaneously as the liquid cools, UF{sub 6} vapor in the cylinder ullage above the liquid desublimes on the upper region of the inner cylinder wall. This solid is a dense, glass-like material which can accumulate to a significant thickness. The thickness of the solid coating on the upper cylinder wall and directly behind the cylinder valve area will vary depending on the conditions during the cooling stage. The amount of time lapsed between UF{sub 6} solidification and UF{sub 6} liquefaction can also affect the UF{sub 6} coating. This is due to the daily ambient heat cycle causing the coating to sublime from the cylinder wall to cooler areas, thus decreasing the thickness. Structural weakening of the dense UF{sub 6} layer also occurs due to cylinder transport vibration and thermal expansion. During cylinder heating, the UF{sub 6} nearest the cylinder wall will liquefy first. As the solid coating behind the cylinder valve begins to liquefy, it results in increased pressure depending upon the available volume for expansion. At the Paducah Gaseous Diffusion Plant (PGDP) during the liquefaction of the UF{sub 6} in cylinders in the UF{sub 6} feed and sampling autoclaves, this pressure increase has resulted in the activation of the systems rupture discs which are rated at 100 pounds per square inch differential.

  8. Observation of the dispersion of wedge waves propagating along cylinder wedge with different truncations by laser ultrasound technique

    Science.gov (United States)

    Jia, Jing; Zhang, Yu; Han, Qingbang; Jing, Xueping

    2017-10-01

    The research focuses on study the influence of truncations on the dispersion of wedge waves propagating along cylinder wedge with different truncations by using the laser ultrasound technique. The wedge waveguide models with different truncations were built by using finite element method (FEM). The dispersion curves were obtained by using 2D Fourier transformation method. Multiple mode wedge waves were observed, which was well agreed with the results estimated from Lagasse's empirical formula. We established cylinder wedge with radius of 3mm, 20° and 60°angle, with 0μm, 5μm, 10μm, 20μm, 30μm, 40μm, and 50μm truncations, respectively. It was found that non-ideal wedge tip caused abnormal dispersion of the mode of cylinder wedge, the modes of 20° cylinder wedge presents the characteristics of guide waves which propagating along hollow cylinder as the truncation increasing. Meanwhile, the modes of 60° cylinder wedge with truncations appears the characteristics of guide waves propagating along hollow cylinder, and its mode are observed clearly. The study can be used to evaluate and detect wedge structure.

  9. Cellobiohydrolase B of Aspergillus niger over-expressed in Pichia pastoris stimulates hydrolysis of oil palm empty fruit bunches

    Directory of Open Access Journals (Sweden)

    James Sy-Keen Woon

    2017-10-01

    Full Text Available Background Aspergillus niger, along with many other lignocellulolytic fungi, has been widely used as a commercial workhorse for cellulase production. A fungal cellulase system generally includes three major classes of enzymes i.e., β-glucosidases, endoglucanases and cellobiohydrolases. Cellobiohydrolases (CBH are vital to the degradation of crystalline cellulose present in lignocellulosic biomass. However, A. niger naturally secretes low levels of CBH. Hence, recombinant production of A. niger CBH is desirable to increase CBH production yield and also to allow biochemical characterisation of the recombinant CBH from A. niger. Methods In this study, the gene encoding a cellobiohydrolase B (cbhB from A. niger ATCC 10574 was cloned and expressed in the methylotrophic yeast Pichia pastoris X-33. The recombinant CBHB was purified and characterised to study its biochemical and kinetic characteristics. To evaluate the potential of CBHB in assisting biomass conversion, CBHB was supplemented into a commercial cellulase preparation (Cellic® CTec2 and was used to hydrolyse oil palm empty fruit bunch (OPEFB, one of the most abundant lignocellulosic waste from the palm oil industry. To attain maximum saccharification, enzyme loadings were optimised by response surface methodology and the optimum point was validated experimentally. Hydrolysed OPEFB samples were analysed using attenuated total reflectance FTIR spectroscopy (ATR-FTIR to screen for any compositional changes upon enzymatic treatment. Results Recombinant CBHB was over-expressed as a hyperglycosylated protein attached to N-glycans. CBHB was enzymatically active towards soluble substrates such as 4-methylumbelliferyl-β-D-cellobioside (MUC, p-nitrophenyl-cellobioside (pNPC and p-nitrophenyl-cellobiotrioside (pNPG3 but was not active towards crystalline substrates like Avicel® and Sigmacell cellulose. Characterisation of purified CBHB using MUC as the model substrate revealed that optimum

  10. Designing local solutions for emptying pit latrines in low-income urban settlements (Malawi)

    Science.gov (United States)

    Chipeta, W. C.; Holm, R. H.; Kamanula, J. F.; Mtonga, W. E.; de los Reyes, F. L.

    2017-08-01

    A lack of effective options in local technology poses challenges when onsite household sanitation facilities are eventually filled to capacity in unplanned settlement areas within Mzuzu City, located in northern Malawi. Vacuum trucks currently dominate the market but focus on emptying septic tanks in the more easily accessible planned settlement areas, rather than servicing the pit latrines common in unplanned settlement areas. As a result, households in the unplanned settlement areas within Mzuzu rely primarily on manual pit emptying (i.e., shoveling by hand) or digging a new pit latrine. These practices have associated health risks and are limited by space constraints. This research focused on filling the technological gap through the design, development, and testing of a pedal powered modified Gulper pump using locally available materials and fabrication. A modified pedal powered Gulper technology was developed and demonstrated to be capable of lifting fecal sludge from a depth of 1.5 m with a mean flow rate of 0.00058 m3/s. If the trash content was low, a typical pit latrine with a volume of 1-4 m3 could be emptied within 1-2 h. Based on the findings in our research Phase IV, the pedal powered Gulper modification is promising as a potential emptying technology for lined pit latrines in unplanned settlement areas. The success rate of the technology is about 17% (5 out 30 sampled lined pit latrines were successful) and reflects the difficulty in finding a single technology that can work well in all types of pit latrines with varying contents. We note that cost should not be the only design criteria and acknowledge the challenge of handling trash in pit latrines.

  11. Numerical Study of Shock-Cylinder Banks Interactions

    International Nuclear Information System (INIS)

    Wang, S.P.; Anderson, M.H.; Oakley, J.G.; Bonazza, R.

    2003-01-01

    A numerical parametric study of shock-cylinder banks interactions is presented using a high resolution Euler solver. Staggered cylinder banks of five rows are chosen with the purpose of modeling IFE reactor cooling tube banks. The effect of the aspect ratio of the intercylinder pitch to the distance between successive cylinder rows on the vertical pressure forces acting on the cylinders with different geometries is investigated. Preliminary results show that the largest vertical force develops on the cylinders of the second or third row. This peak pressure force increases with decreasing values of the aspect ratio. It is shown that an increasing second force peak also appears on the successive rows, starting with the second one, with decreasing aspect ratio. It is also observed that the force on the last-row cylinders basically decreases to the level of that on the first row. The results are useful for the optimal design of the cooling tubes system of IFE reactors

  12. Scintigraphic evaluation of gastric emptying and motility; Nuklearmedizinische Diagnostik der Magenmotilitaet

    Energy Technology Data Exchange (ETDEWEB)

    Linke, R. [Klinik und Poliklinik fuer Nuklearmedizin, Ludwig-Maximilians-Univ. Muenchen (Germany)

    2003-06-01

    The stomach consists of two functionally distinct parts. The fundus and upper corpus mainly serve as a reservoir and exert primarily a tonic activity, which presses ingesta towards the antrum and duodenum. The phasic contractility of the lower corpus and antrum cause mechanical breakdown and mixing of the food particels. A complex regulation of these mechanisms provides a regular gastric emptying. Various disorders such as diabetes mellitus, mixed connective tissue diseases, gastritis, tumors, dyspeptic disorders but also drugs and gastric surgery may influence or impair gastric function and may cause typical symptoms such as upper abdominal discomfort, bloating, nausea and vomiting. However, the interpretation of gastrointestinal symptoms often is difficult. Radionuclide studies of gastric emptying and motility are the most physiologic tools available for studying gastric motor function. Gastric scintigraphy is non-invasive, uses physiologic meal and is quantitative. Emptying curves generated from the gastric ROI offer information whether a disorder is accompanied by a regular, fast or slow gastric emptying. Data on gastric contractions (amplitude and frequency) provide additional information to results obtained by conventional emptying studies. Depending on the underlying disorder, gastric emptying and peristalsis showed both corresponding and discrepant findings. Therefore, both parameters should be routinely assessed to further improve characterisation of gastric dysfunction by scintigraphy. (orig.) [German] Proximaler und distaler Magen haben funktionell unterschiedliche Aufgaben. Waehrend der proximale Magen die Nahrung voruebergehend speichert und ueber die Generierung eines gastroduodenalen Druckgefaelles eine fraktionierte Entleerung in den Duenndarm bewirkt, dient die Peristaltik des distalen Magens der Durchmischung und Zerkleinerung des Speisebreis. Eine komplexe hormonelle, humorale und nervale Regulation dieser ineinandergreifenden Funktionen

  13. Portable load-cell based system for weighing UF6 cylinders

    International Nuclear Information System (INIS)

    Fainberg, A.; Gordon, D.; Dermendjiev, E.; Terrey, D.; Mitchell, R.

    1982-01-01

    A load-cell-based portable weighing system which is capable of verifying the weights of 2.2 tonne 30-inch UF 6 cylinders has been developed by the US National Bureau of Standards (NBS). This system weighs about 13 kg and has an attainable accuracy of about 1 kg. After an initial calibration at NBS, the system is ready for use in the field. Approximately 5 to 10 minutes are needed for assembly, and, if an overhead crane has access to all cylinders to be weighed, from 10 to 15 weighings may be performed in one hour. During the past year the system has been tested at several facilities around the world with satisfactory results and with favorable comments from the facility operators. Results of several tests are presented in this paper

  14. [Infection risk through the reuse of "used" cylinder ampoules for dental local anaesthesia (author's transl)].

    Science.gov (United States)

    Gräf, W

    1981-01-01

    The phenomenon of so-called syringe internal infection with cylinder ampoule syringes customarily used in dental local anaesthesia is discussed from the view-point of infection hygiene. The contamination rate of the residual content-of used cylinder ampoules has been determined by means of bacteriological model tests with E. coli under the conditions of the cannulae removal phenomenon and the reflux phenomenon caused by tissue overpressure resulting from the injection. It has been shown that - as result of changing a contaminated cannula with the commonly used Uniject cylinder ampoule injection system, the probability that the cylinder ampoule residual contents are infected in 93% using metallic head cannulae and 78% with disposable screw-on cannulae; - even with the lever syringe systems for intraligamentary anaesthesia, changing contaminated, ultra-thin special cannulae leads with 11-12% probability to infection of the cylinder ampoule residual contents; - injections with a tissue counterpressure of only 1 atm result in a 100% contamination rate of the cylinder ampoules through reflux phenomena. The test results lead to the indispensable hygienic demand that - irrespective of which injection system is used - used cylinder ampoules must not be reused with other patients. The increasingly high contamination ratio (0.5 - 1.0%) of our population with hepatitis B viruses places increased demands on the need for care on the part of the dentist and physician.

  15. Radionuclide study of gastric emptying in anorexia nervosa patients

    International Nuclear Information System (INIS)

    Shih, W.J.; Domstad, P.A.; Humphries, L.; Castellanos, F.X.; De Land, F.H.

    1986-01-01

    To evaluate gastric emptying, 20 patients with anorexia nervosa were given 150 μCi of Tc-99m triethylene tetraamine polystyrene resin in cereal and were imaged in the supine position. Data were accumulated at 5-minute intervals to determine the gastric emptying time (GET). The GET results were divided into three categories: prolonged (10 patients); rapid (eight); and normal (two). Although all patients had symptoms of gastric dysfunction, only 50% had prolonged GET. This study allows the objective documentation of gastric emptying and the separation of patients with rapid or normal GET from those with prolonged GET, who might benefit from metoclopramide

  16. Theoretical and experimental stress analyses of ORNL thin-shell cylinder-to-cylinder model 3

    International Nuclear Information System (INIS)

    Gwaltney, R.C.; Bolt, S.E.; Corum, J.M.; Bryson, J.W.

    1975-06-01

    The third in a series of four thin-shell cylinder-to-cylinder models was tested, and the experimentally determined elastic stress distributions were compared with theoretical predictions obtained from a thin-shell finite-element analysis. The models are idealized thin-shell structures consisting of two circular cylindrical shells that intersect at right angles. There are no transitions, reinforcements, or fillets in the junction region. This series of model tests serves two basic purposes: the experimental data provide design information directly applicable to nozzles in cylindrical vessels; and the idealized models provide test results for use in developing and evaluating theoretical analyses applicable to nozzles in cylindrical vessels and to thin piping tees. The cylinder of model 3 had a 10 in. OD and the nozzle had a 1.29 in. OD, giving a d 0 /D 0 ratio of 0.129. The OD/thickness ratios for the cylinder and the nozzle were 50 and 7.68 respectively. Thirteen separate loading cases were analyzed. In each, one end of the cylinder was rigidly held. In addition to an internal pressure loading, three mutually perpendicular force components and three mutually perpendicular moment components were individually applied at the free end of the cylinder and at the end of the nozzle. The experimental stress distributions for all the loadings were obtained using 158 three-gage strain rosettes located on the inner and outer surfaces. The loading cases were also analyzed theoretically using a finite-element shell analysis developed at the University of California, Berkeley. The analysis used flat-plate elements and considered five degrees of freedom per node in the final assembled equations. The comparisons between theory and experiment show reasonably good agreement for this model. (U.S.)

  17. Theoretical and experimental stress analyses of ORNL thin-shell cylinder-to-cylinder model 4

    International Nuclear Information System (INIS)

    Gwaltney, R.C.; Bolt, S.E.; Bryson, J.W.

    1975-06-01

    The last in a series of four thin-shell cylinder-to-cylinder models was tested, and the experimentally determined elastic stress distributions were compared with theoretical predictions obtained from a thin-shell finite-element analysis. The models in the series are idealized thin-shell structures consisting of two circular cylindrical shells that intersect at right angles. There are no transitions, reinforcements, or fillets in the junction region. This series of model tests serves two basic purposes: (1) the experimental data provide design information directly applicable to nozzles in cylindrical vessels, and (2) the idealized models provide test results for use in developing and evaluating theoretical analyses applicable to nozzles in cylindrical vessels and to thin piping tees. The cylinder of model 4 had an outside diameter of 10 in., and the nozzle had an outside diameter of 1.29 in., giving a d 0 /D 0 ratio of 0.129. The OD/thickness ratios were 50 and 20.2 for the cylinder and nozzle respectively. Thirteen separate loading cases were analyzed. For each loading condition one end of the cylinder was rigidly held. In addition to an internal pressure loading, three mutually perpendicular force components and three mutually perpendicular moment components were individually applied at the free end of the cylinder and at the end of the nozzle. The experimental stress distributions for each of the 13 loadings were obtained using 157 three-gage strain rosettes located on the inner and outer surfaces. Each of the 13 loading cases was also analyzed theoretically using a finite-element shell analysis developed at the University of California, Berkeley. The analysis used flat-plate elements and considered five degrees of freedom per node in the final assembled equations. The comparisons between theory and experiment show reasonably good agreement for this model. (U.S.)

  18. Cracking investigation of Monju emergency generator C unit cylinder liner. Cylinder liner soundness confirmation by a fall cause of the materials strength of the cylinder liner and the supersonic wave speed

    International Nuclear Information System (INIS)

    Kobayashi, Takanori; Sakon, Miyoji; Takada, Osamu; Hatori, Masakazu; Sakamoto, Tsutomu; Sato, Toshiyuki; Kazama, Akihito; Ishizawa, Yoshihiro; Igawa, Katsuhisa; Nakae, Hideo

    2012-02-01

    I confirmed a leak of the effluent gas from cylinder part during a load examination after the check of the emergency generator C unit on December 28, 2010 of the facilities check average and confirmed crack in No.8 cylinder liner part. As a result, because it was not performed oil pressure management properly without attaching an oil pressure gauge when I removed cylinder liner about the cause, crack occurred by having been able to write excessive stress for the cylinder liner and reached damage. By a process of this investigation, a fall of the materials strength of some cylinder liner was confirmed, but because a lead ingredient got mixed with materials by a casting process at the time of the production of the cylinder liner, as for this, Widmannstaetten graphite occurred, and it became clear that materials strength fell. In addition, I performed inspection by the supersonic wave velocity measurement as technique to distinguish this Widmannstaetten graphite easily and confirmed that I was effective. Because this report was the knowledge that there were little inspection contents which modified soundness confirmation technique of the cylinder liner with the possibility of materials strength fall of the cylinder liner by the Widmannstaetten graphite outbreak and the mixture of lead for a report example in the field of cast iron, I gathered it in this report. (author)

  19. Effect of cisapride on gastric emptying in dyspeptic patients.

    Science.gov (United States)

    Urbain, J L; Siegel, J A; Debie, N C; Pauwels, S P

    1988-07-01

    The effect of the new gastrokinetic agent cisapride on gastric emptying was evaluated in 17 dyspeptic patients using the dual radionuclide technique. Eight patients with idiopathic dyspepsia and nine postsurgical dyspeptic patients were studied and compared to a control group. Gastric emptying of solids and liquids was determined after ingestion of a standardized meal using 99mTc-sulfur colloid scrambled eggs as the solid phase and [111In]DTPA-labeled water as the liquid phase. Following a basal study and on a separate occasion, each patient received an intravenous bolus of 10 mg of cisapride after ingestion of the test meal; 10 of the patients were restudied after a two-week period of chronic oral administration of the drug (10 mg four times a day). Baseline gastric emptying of solids was significantly delayed in idiopathic and postsurgical patients; liquid emptying was only delayed in the postsurgical group. Intravenous and oral administration of cisapride significantly shortened gastric emptying in both groups. In all but one patient, the clinical improvement was confirmed by the test. Cisapride appears to be a good alternative to metoclopramide and domperiodone in the treatment of dyspeptic patients. The dual radionuclide technique appears to be a useful physiologic tool for evaluating and predicting the efficacy of a gastric prokinetic therapy in man.

  20. Scintigraphic measurements of gastric emptying corrected for differences in tissue attenuation

    Energy Technology Data Exchange (ETDEWEB)

    Lauritzen, J.B.; Hoejgaard, L.; Uhrenholdt, A. (Copenhagen Univ. (Denmark). Hvidovre Hospital)

    1983-10-01

    In order to evaluate the importance of variations in tissue attenuation in scintigraphic measurements of gastric emptying, both in vivo and in vitro measurements of count rates from an encapsulated sup(99m)Tc dose were performed in different parts of the stomach. The obtained individual tissue correction factors were applied in the calculation of gastric emptying rates by gamma camera in healthy volunteers. The results showed that the anterior gamma camera scan without correction for differences in tissue attenuation underestimated the gastric emptying rate by 11% if the results were expressed as percentage meal emptied over 60 minutes.

  1. Orlistat accelerates gastric emptying and attenuates GIP release in healthy subjects

    DEFF Research Database (Denmark)

    Enç, Feruze Yilmaz; Ones, Tunç; Akin, H Levent

    2008-01-01

    Orlistat, an inhibitor of digestive lipases, is widely used for the treatment of obesity. Previous reports on the effect of orally ingested orlistat together with a meal on gastric emptying and secretion of gut peptides that modulate postprandial responses are controversial. We investigated...... the effect of ingested orlistat on gastric emptying and plasma responses of gut peptides in response to a solid mixed meal with a moderate energy load. In healthy subjects, gastric emptying was determined using scintigraphy and studies were performed without and with 120 mg of orlistat in pellet form......, implying that inhibition of fat absorption modifies determinants of gastric emptying of a meal. Orlistat administered similar to its use in obesity treatment accelerates gastric emptying of a solid mixed meal with a moderate energy load and profoundly attenuates release of GIP without appreciably altering...

  2. Approximation of Surfaces by Cylinders

    DEFF Research Database (Denmark)

    Randrup, Thomas

    1998-01-01

    We present a new method for approximation of a given surface by a cylinder surface. It is a constructive geometric method, leading to a monorail representation of the cylinder surface. By use of a weighted Gaussian image of the given surface, we determine a projection plane. In the orthogonal...

  3. Efficient Capsid Antigen Presentation From Adeno-Associated Virus Empty Virions In Vivo.

    Science.gov (United States)

    Pei, Xiaolei; Earley, Lauriel Freya; He, Yi; Chen, Xiaojing; Hall, Nikita Elexa; Samulski, Richard Jude; Li, Chengwen

    2018-01-01

    Adeno-associated virus (AAV) vectors have been successfully applied in clinical trials for hemophilic patients. Although promising, the clinical results suggest that the capsid-specific CD8+T cell response has a negative effect on therapeutic success. In an in vitro analysis using an engineered AAV virus carrying immune-dominant SIINFEKL peptide in the capsid backbone, we have previously demonstrated that capsid antigen presentation from full (genome containing) AAV capsids requires endosome escape and is proteasome dependent and that no capsid antigen presentation is induced from empty virions. In the present study, we examined capsid antigen presentation from administration of empty virions in animal models. In wild-type mice, similar to AAV full particles, capsid antigen presentation from AAV empty virion infection was dose dependent, and the kinetics studies showed that antigen presentation was detected from 2 to 40 days after AAV empty virion administration. In the transporter associated with antigen processing 1 deficient (TAP-/-) mice, capsid antigen presentation was inhibited from both AAV full and empty virions, but higher inhibition was achieved from AAV full particle administration than that from empty virions. This indicates that the pathway of capsid antigen presentation from AAV transduction is dependent on proteasome-mediated degradation of AAV capsids (mainly for full particles) and that the endosomal pathway may also play a role in antigen presentation from empty particles but not full virions. The capsid antigen presentation efficiency from AAV preparations was positively correlated with the amount of empty virions contaminated with full particles. Collectively, the results indicate that contamination of AAV empty virions induces efficient antigen presentation in vivo and the mechanism of capsid antigen presentation from empty virions involves both endosomal and proteasomal pathways. The elucidation of capsid antigen presentation from AAV empty

  4. Measurement of gastric emptying during and between meal intake in free-feeding Lewis rats.

    Science.gov (United States)

    van der Velde, P; Koslowsky, I; Koopmans, H S

    1999-02-01

    A new scintigraphic measurement technique is described that allows accurate assessment of gastric emptying in between as well as during a number of successive meals. Measurements were made every minute of food intake, gastric nutrient filling, and gastric emptying over a 6 h, 40 min period in conscious, free-feeding, loosely restrained rats. Before receiving access to the food, the animals had been deprived for a period of 31 h. Over the full duration of the experiment, an average rate of gastric emptying of 2.46 +/- 0.18 (SE) kcal/h was established. During most meals, however, the gastric emptying rate was increased so that an average of 26.9 +/- 2.7% of the ingested calories was emptied while the animals were feeding, with an average emptying rate of 0.15 +/- 0.014 kcal/min or 8.88 +/- 0.84 kcal/h. This transient increase in the rate of gastric emptying was followed by a subsequent slowing of gastric emptying after meal termination; in the 10-min postmeal interval, an average emptying rate of 0.96 +/- 0.12 kcal/h was found. Despite these fluctuations during and immediately after meals, a relatively constant rate of caloric emptying is maintained over longer periods. There were no differences between the emptying rate during the first meal when the gastrointestinal tract was still empty, compared with later meals when the gastrointestinal tract had been filled with food. The emptying rate during the 10-min postmeal interval, however, was significantly reduced during later meals. The results suggest that gastric emptying is controlled by different mechanisms during and after the ingestion of food and that these mechanisms remain in effect at various degrees of gastrointestinal filling.

  5. Analyses on interaction of internal and external surface cracks in a pressurized cylinder by hybrid boundary element method

    International Nuclear Information System (INIS)

    Chai Guozhong; Fang Zhimin; Jiang Xianfeng; Li Gan

    2004-01-01

    This paper presents a comprehensive range of analyses on the interaction of two identical semi-elliptical surface cracks at the internal and external surfaces of a pressurized cylinder. The considered ratios of the crack depth to crack length are b/a=0.25, 0.5, 0.75 and 1.0; the ratios of the crack depth to wall thickness of the cylinder are 2b/t=0.2, 0.4, 0.6, 0.7 and 0.8. Forty crack configurations are analyzed and the stress intensity factors along the crack front are presented. The numerical results show that for 2b/t<0.7, the interaction leads to a decrease in the stress intensity factors for both internal and external surface cracks, compared with a single internal or external surface crack. Thus for fracture analysis of a practical pressurized cylinder with two identical semi-elliptical surface cracks at its internal and external surfaces, a conservative result is obtained by ignoring the interaction

  6. The primary empty sella in children and its significance

    International Nuclear Information System (INIS)

    Tokiguchi, Susumu; Tsuchiya, Toshiaki; Ito, Jusuke

    1983-01-01

    The primary empty sella has been thought to be rare in children; only a few children have been described in the literature. The majority of such cases have been associated with congenital anomalies, optic atrophies, or cerebrospinal fluid rhinorrheas. We now report four cases of the primary empty sella in children. Two of the patients(Case 1 and Case 3) were prepubescent and had primary generalized epilepsy, while Case 2 and Case 4 complained of attacks of vascular headache and peri-orbital pain respectively. None of them showed any clinical evidence of endocrine disturbance. Ophthalmological examination revealed no abnormalities. The association of the primary empty sella with such disorders as primary epilepsy, attacks of vascular headache, and peri-orbital pain were thought to be almost certainly coincidental; the possibility was suggested that the empty sella might be present in children as an anatomical variant or as an acquired process in a certain percentage of them. (author)

  7. Chemical modification of organoclay cloisite ®30B with silane 3-aminopropyltriethoxysilane

    International Nuclear Information System (INIS)

    Bertuoli, P.T.; Frizzo, V.P.; Zattera, A.J.; Scienza, L.C.

    2014-01-01

    The montmorillonite (MMT) is the inorganic phase more used in obtaining polymer nanocomposites. To improve the compatibility and dispersion of MMT in the polymer resin, many researchers have performed the process of functionalization of the clay with silane. This study was performed with the objective of modifying the Cloisite®30B clay with 3-aminopropyltriethoxysilane (APS). The modification was carried out by ion-exchange method using 10 g of clay Cloisite®30B (MMT-30B), 500 mL of hydroalcoholic solution (75/25 v/v) and 10 g of silane. The clay modified with silane (S-MMT_3_0_B) was characterized by X-ray diffraction (XRD), thermogravimetric analysis (TGA) and Fourier transform infrared (FTIR). Through the XRD was observed an increase in the basal spacing d_0_0_1 of 1.82 to 2.2 nm. With the analysis of TGA was observed that S-MMT_3_0_B showed greater weight loss than MMT-30B due to decomposition of the silane. The presence of band at 1562 cm-1 in the FTIR spectrum of S-MMT_3_0_B confirmed the presence of silane in the structure of the modified clay. (author)

  8. Evaluation of functional scintigraphy of gastric emptying by the principal component method

    Energy Technology Data Exchange (ETDEWEB)

    Haeussler, M.; Eilles, C.; Reiners, C.; Moll, E.; Boerner, W.

    1980-10-01

    Gastric emptying of a standard semifluid test-meal, labeled with /sup 99/sup(m)Tc-DTPA, was studied by functional scintigraphy in 88 subjects (normals, patients with duodenal and gastric ulcer before and after selective proximal vagotomy with and without pyloroplasty). Gastric emptying curves were analysed by the method of principal components. Patients after selective proximal vagotomy with pyloroplasty showed an rapid initial emptying, whereas this was a rare finding in patients after selective proximal vagotomy without pyloroplasty. The method of principal components is well suited for mathematical analysis of gastric emptying; nevertheless the results are difficult to interpret. The method has advantages when looking at larger collectives and allows a separation into groups with different gastric emptying.

  9. Muscle Weakness in the Empty and Full Can Tests Cannot Differentiate Rotator Cuff Tear from Cervical Spondylotic Amyotrophy: Pain Provocation is a Useful Finding.

    Science.gov (United States)

    Iwata, Eiichiro; Shigematsu, Hideki; Inoue, Kazuya; Egawa, Takuya; Sakamoto, Yoshihiro; Tanaka, Yasuhito

    2017-01-01

    Rotator cuff tears and cervical spondylotic amyotrophy (CSA) are often confused as the main symptom in those with difficulty in shoulder elevation. Empty and full can tests are frequently used for the clinical diagnosis of rotator cuff tears. The aim of the present study was to investigate whether the empty and full can test results can help differentiate rotator cuff tears from CSA. Twenty-seven consecutive patients with rotator cuff tears and 25 with CSA were enrolled. We prospectively performed empty and full can tests in patients with rotator cuff tears and CSA. The following signs were considered positive: (a) muscle weakness during the empty can test, (b) muscle weakness during the full can test, (c) pain provocation during the empty can test, and (d) pain provocation during the full can test. We calculated the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of rotator cuff tears for each positive finding. The sensitivity and specificity of each index were as follows (sensitivity, specificity, PPV, NPV): (a) 77.8%, 0%, 45.7%, 0%; (b) 66.7%, 4.0%, 42.9%, 10.0%; (c) 88.9%, 96.0%, 96.0%, 88.9%; and (d) 74.1%, 96.0%, 95.2%, 77.4%. There were significant differences for each index. Muscle weakness during the empty and full can tests was not useful in differentiating rotator cuff tears from CSA because of low specificity and PPV. However, pain provocation was useful in differentiating these two conditions because of high specificity and PPV.

  10. UF{sub 6} cylinder fire test

    Energy Technology Data Exchange (ETDEWEB)

    Park, S.H. [Oak Ridge K-25 Site, Oak Ridge, TN (United States)

    1991-12-31

    With the increasing number of nuclear reactors for power generation, there is a comparable increase in the amount of UF{sub 6} being transported. Likewise, the probability of having an accident involving UF{sub 6}-filled cylinders also increases. Accident scenarios which have been difficult to assess are those involving a filled UF{sub 6} cylinder subjected to fire. A study is underway at the Oak Ridge K-25 Site, as part of the US DOE Enrichment Program, to provide empirical data and a computer model that can be used to evaluate various cylinder-in-fire scenarios. It is expected that the results will provide information leading to better handling of possible fire accidents as well as show whether changes should be made to provide different physical protection during shipment. The computer model being developed will be capable of predicting the rupture of various cylinder sizes and designs as well as the amount of UF{sub 6}, its distribution in the cylinder, and the conditions of the fire.

  11. a design to digitalize hydraulic cylinder control of a machine tool

    African Journals Online (AJOL)

    Dr Obe

    1995-09-01

    Sep 1, 1995 ... Department of Mechanical Engineering. FEDERAL UNIVERSITY OF TECHNOLOGY, OWERRI,. P.M.B. 1526, OWERRI. ABSTRACT. Conventionally hydraulic piston - cylinder servos are actuated using analogue controls for machine tool axis drives. In this paper a design of the axis control system of an NC ...

  12. Solid Test Meal to Measure the Gastric Emptying with Magnetogastrography

    International Nuclear Information System (INIS)

    Reynaga-Ornelas, M. G.; Roca-Chiapas, J. M. de ls; Cordova-Fraga, T.; Bernal, J. J.; Sosa, M.

    2008-01-01

    The gastric emptying is the time of evacuating the food ingested from the stomach to the duodenum in a controlled rate. Diverse studies express the results of the gastric emptying in form of half-time (t 1/2 ). The Magnetogastrography (MGG) is a biomagnetic technique that has the advantage of not being invasive, radiation free and does not interfere with the privacy of the subject. The objective was to analyze the magnetic signal of magnetic tracers mixed in a solid food to measure gastric emptying using Magnetogastrography. The ingested test meal displayed a magnetic signal, which served to obtain the signal registered by the fluxgate and the peristaltic contractions could be calculated while the stomach was emptying. The solid food product developed results to work satisfactorily in magnetogastrography

  13. A study of flow patterns for staggered cylinders at low Reynolds number by spectral element method

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Li-Chieh; Chen, Chien-Lin; Ye, Jian-Zhi [National Yunlin University of Science and Technology, Taiwan (China)

    2017-06-15

    This study investigates the pattern of flow past two staggered array cylinders using the spectral element method by varying the distance between the cylinders and the angle of incidence (α) at low Reynolds numbers (Re = 100-800). Six flow patterns are identified as Shear layer reattachment (SLR), Induced separation (IS), Vortex impingement (VI), Synchronized vortex shedding (SVS), Vortex pairing and enveloping (VPE), and Vortex pairing splitting and enveloping (VPSE). These flow patterns can be transformed from one to another by changing the distance between the cylinders, the angle of incidence, or Re. SLR, IS and VI flow patterns appear in regimes with small angles of incidence (i.e., α ≤ 30° ) and hold only a single von Karman vortex shedding in a wake with one shedding frequency. SVS, VPE and VPSE flow patterns appear in regimes with large angles of incidence (i.e., 30° ≤ α ≤ 50° ) and present two synchronized von Karman vortices. Quantitative analyses and physical interpretation are also conducted to determine the generation mechanisms of the said flow patterns.

  14. Three-dimensional vortex flow near the endwall of a short cylinder in crossflow: Uniform-diameter circular cylinder

    International Nuclear Information System (INIS)

    Chen, S.B.; Sanitjai, S.; Ghosh, K.; Goldstein, R.J.

    2012-01-01

    Flow characteristics, around a short uniform-diameter circular cylinder in crossflow, are investigated experimentally. Extensive flow visualization using oil-lampblack and smoke-wire methods have been performed. Near-wake velocity measurements have been performed using a hotwire anemometer. Complex secondary flows are observed on and around the cylinder in crossflow. Multiple vortices are observed in the horseshoe vortex system near the cylinder–endwall junction. Based on this flow visualization and local mass transfer measurement results, a six-vortex secondary flow model has been proposed. - Highlights: ► Flow visualizations and velocity measurements for a short circular cylinder. ► Six vortices in the horseshoe vortex system upstream of the base of the cylinder. ► Cross-stream turbulence intensity profiles show a similarity in their shape.

  15. Performance of a Horizontal Double Cylinder Type of Fresh Coffee Cherries Pulping Machine

    Directory of Open Access Journals (Sweden)

    Sukrisno Widyotomo

    2009-05-01

    Full Text Available Pulping is one important step in wet coffee processing method. Usually, pulping process uses a machine which constructed using wood or metal materials. A horizontal single cylinder type coffee pulping machine is the most popular machine in coffee processor and market. One of the weakness of a horizontal single cylinder type coffee pulping machine is high of broken beans. Broken beans is one of major aspect in defect system that result in low quality. Indonesian Coffee and Cocoa Research Institute has designed and tested a horizontal double cylinder type coffee pulping machine. Material tested is Robusta cherry, mature, 60—65% (wet basis moisture content, which size compostition of coffee cherries was 50.8% more than 15 mm diameter, 32% more than 10 mm diameter, and 16.6% to get through 10 mm hole diameter; 690—695 kg/m3 bulk density, and clean from methal and foreign materials. The result showed that this machine has 420 kg/h optimal capacity in operational conditions, 1400 rpm rotor rotation speed for unsorted coffee cherries with composition 53.08% whole parchment coffee, 16.92% broken beans, and 30% beans in the wet skin. For small size coffee cherries, 603 kg/h optimal capacity in operational conditions, 1600 rpm rotor rotation speed with composition 51.30% whole parchment coffee, 12.59% broken beans, and 36.1% beans in the wet skin. Finally, for medium size coffee cherries, 564 kg/h optimal capacity in operational conditions, 1800 rpm rotor rotation speed with composition 48.64% whole parchment coffee, 18.5% broken beans, and 32.86% beans in the wet skin.Key words : coffee, pulp, pulper, cylinder, quality.

  16. Effect of cisapride on gastric emptying in dyspeptic patients

    International Nuclear Information System (INIS)

    Urbain, J.L.; Siegel, J.A.; Debie, N.C.; Pauwels, S.P.

    1988-01-01

    The effect of the new gastrokinetic agent cisapride on gastric emptying was evaluated in 17 dyspeptic patients using the dual radionuclide technique. Eight patients with idiopathic dyspepsia and nine postsurgical dyspeptic patients were studied and compared to a control group. Gastric emptying of solids and liquids was determined after ingestion of a standardized meal using /sup 99m/Tc-sulfur colloid scrambled eggs as the solid phase and [ 111 In]DTPA-labeled water as the liquid phase. Following a basal study and on a separate occasion, each patient received an intravenous bolus of 10 mg of cisapride after ingestion of the test meal; 10 of the patients were restudied after a two-week period of chronic oral administration of the drug (10 mg four times a day). Baseline gastric emptying of solids was significantly delayed in idiopathic and postsurgical patients; liquid emptying was only delayed in the postsurgical group. Intravenous and oral administration of cisapride significantly shortened gastric emptying in both groups. In all but one patient, the clinical improvement was confirmed by the test. Cisapride appears to be a good alternative to metoclopramide and domperiodone in the treatment of dyspeptic patients. The dual radionuclide technique appears to be a useful physiologic tool for evaluating and predicting the efficacy of a gastric prokinetic therapy in man

  17. Effect of cisapride on gastric emptying in dyspeptic patients

    Energy Technology Data Exchange (ETDEWEB)

    Urbain, J.L.; Siegel, J.A.; Debie, N.C.; Pauwels, S.P.

    1988-07-01

    The effect of the new gastrokinetic agent cisapride on gastric emptying was evaluated in 17 dyspeptic patients using the dual radionuclide technique. Eight patients with idiopathic dyspepsia and nine postsurgical dyspeptic patients were studied and compared to a control group. Gastric emptying of solids and liquids was determined after ingestion of a standardized meal using /sup 99m/Tc-sulfur colloid scrambled eggs as the solid phase and (/sup 111/In)DTPA-labeled water as the liquid phase. Following a basal study and on a separate occasion, each patient received an intravenous bolus of 10 mg of cisapride after ingestion of the test meal; 10 of the patients were restudied after a two-week period of chronic oral administration of the drug (10 mg four times a day). Baseline gastric emptying of solids was significantly delayed in idiopathic and postsurgical patients; liquid emptying was only delayed in the postsurgical group. Intravenous and oral administration of cisapride significantly shortened gastric emptying in both groups. In all but one patient, the clinical improvement was confirmed by the test. Cisapride appears to be a good alternative to metoclopramide and domperiodone in the treatment of dyspeptic patients. The dual radionuclide technique appears to be a useful physiologic tool for evaluating and predicting the efficacy of a gastric prokinetic therapy in man.

  18. Optimization and improvement of Halbach cylinder design

    DEFF Research Database (Denmark)

    Bjørk, Rasmus; Bahl, Christian Robert Haffenden; Smith, Anders

    2008-01-01

    possible volume of magnets with a given mean flux density in the cylinder bore. The volume of the cylinder bore could also be significantly increased by only slightly increasing the volume of the magnets, for a fixed mean flux density. Placing additional blocks of magnets on the end faces of the Halbach...... that this parameter was optimal for long Halbach cylinders with small rex. Using the previously mentioned additional blocks of magnets can improve the parameter by as much as 15% as well as improve the homogeneity of the field in the cylinder bore. ©2008 American Institute of Physics...

  19. Combined Effect of Surface Roughness and Wake Splitter Plate on the Aerodynamic Characteristics of a Circular Cylinder

    Science.gov (United States)

    Saisanthosh, Iyer; Arunkumar, K.; Ajithkumar, R.; Srikrishnan, A. R.

    2017-09-01

    This paper is focussed on numerical investigation of flow around a stationary circular cylinder (diameter, D) with selectively applied surface roughness (roughness strips with thickness ‘k’) in the presence of a wake splitter plate (length, L). The plate leading edge is at a distance of ‘G’ from the cylinder base. For this study, the commercial software ANSYS Fluent is used. Fluid considered is water. Study was conducted the following cases (a) plain cylinder (b) cylinder with surface roughness (without splitter plate) (c) Cylinder with splitter plate (without surface roughness) and (d) cylinder with both roughness and splitter plate employed. The study Reynolds number (based on D) is 17,000 and k/δ = 1.25 (in all cases). Results indicate that, for cylinder with splitter plate (no roughness), lift coefficient gradually drops till G/D=1.5 further to which it sharply increases. Whereas, drag coefficient and Strouhal number undergoes slight reduction till G/D=1.0 and thereafter, gradually increase. Circumferential location of strip (α) does not influence the aerodynamic parameters significantly. With roughness alone, drag is magnified by about 1.5 times and lift, by about 2.7 times that of the respective values of the smooth cylinder. With splitter plate, for roughness applied at all ‘α’ values, drag and lift undergoes substantial reduction with the lowest value attained at G/D=1.0.

  20. Where are kids getting their empty calories? Stores, schools, and fast food restaurants each play an important role in empty calorie intake among US children in 2009-2010

    Science.gov (United States)

    Poti, Jennifer M.; Slining, Meghan M.; Popkin, Barry M.; Kenan, W.R.

    2013-01-01

    Consumption of empty calories, the sum of energy from added sugar and solid fat, exceeds recommendations, but little is known about where US children obtain these empty calories. The objectives of this study were to compare children's empty calorie consumption from retail food stores, schools, and fast food restaurants; to identify food groups that were top contributors of empty calories from each location; and to determine the location providing the majority of calories for these key food groups. This cross-sectional analysis used data from 3,077 US children aged 2-18 years participating in the 2009-2010 National Health and Nutrition Examination Survey. The empty calorie content of children's intake from stores (33%), schools (32%), and fast food restaurants (35%) was not significantly different in 2009-2010. In absolute terms, stores provided the majority of empty calorie intake (436 kcal). The top contributors of added sugar and solid fat from each location were similar: sugar sweetened beverages (SSBs), grain desserts, and high-fat milk from stores; high-fat milk, grain desserts, and pizza from schools; and SSBs, dairy desserts, french fries, and pizza from fast food restaurants. Schools contributed about 20% of children's intake of high-fat milk and pizza. In conclusion, these findings support the need for continued efforts to reduce empty calorie intake among US children aimed not just at fast food restaurants, but also at stores and schools. The importance of reformed school nutrition standards was suggested, as prior to their implementation, schools resembled fast food restaurants in their contributions to empty calorie intake. PMID:24200654

  1. Delayed postoperative gastric emptying following intrathecal morphine and intrathecal bupivacaine.

    LENUS (Irish Health Repository)

    Lydon, A M

    2012-02-03

    PURPOSE: A decrease in the rate of gastric emptying can delay resumption of enteral feeding, alter bioavailability of orally administered drugs, and result in larger residual gastric volumes, increasing the risk of nausea and vomiting. We compared the effects of 1) intrathecal bupivacaine (17.5 mg) and 2) the combination of intrathecal morphine (0.6 mg) and intrathecal bupivacaine (17.5 mg) on the rate of gastric emptying in patients undergoing elective hip arthroplasty. METHODS: Twenty four fasting ASA 1-3 patients were randomly assigned, in a double blind manner, to receive intrathecal hyperbaric bupivacaine (17.5 mg), either alone (group 1), or followed by intrathecal morphine (0.6 mg) (group 2). Gastric emptying was measured (using an acetaminophen absorption technique), twice in each patient; preoperatively, and approximately one hour postoperatively. Gastric emptying parameters are: AUC (area under the plasma acetaminophen concentration time curve), maximum plasma acetaminophen concentration (Cmax), and time to Cmax (tCmax), analyzed using paired Student\\'s t tests. RESULTS: Gastric emptying rates were reduced in both group 1 (AUC = 14.98 (3.8) and 11.05 (4.6) pre- and postoperatively, respectively) and group 2 (AUC = 13.93 (3.59) and 6.4 (3.42) pre- and postoperatively, respectively); the magnitude of the reduction was greater in group 2 [AUC (P = 0.04), Cmax (P = 0.05), tCmax (P = 0.13)]. CONCLUSION: The combination of intrathecal morphine (0.6 mg) and intrathecal bupivacaine (17.5 mg) delays gastric emptying postoperatively.

  2. 700 bar hydrogen cylinder design, testing and certification

    International Nuclear Information System (INIS)

    Duncan, M.

    2004-01-01

    'Full text:' Light weight and high pressure cylinders for compressed hydrogen storage are essential components for fuel cell vehicles. Storage volume and mass are two key considerations. Current on-board hydrogen storage systems are based on a maximum pressure of 350 bar. While 350 bar systems are excellent solutions for many applications, some situations required higher storage densities due to space restrictions. As a result significant research and development work has been expended by cylinder manufacturers, systems providers, testing agencies and automotive manufacturers to develop 700 bar systems to reduce storage volume. Dynetek Industries Ltd has proactively developed a range of 700 bar storage cylinders based on a seamless aluminum liner over wrapped with a carbon fiber composite. This paper presents the challenges and processes involved in the design, testing and certification of the Dynetek Industries Ltd 700 bar cylinder. The paper also provides reasoning for further volume and mass optimization of compressed hydrogen cylinders by incorporating realistic cylinder usage parameters into standards. In particular the overly conservative fill life requirement for cylinders will be examined. (author)

  3. Cylinder Position Servo Control Based on Fuzzy PID

    Directory of Open Access Journals (Sweden)

    Shibo Cai

    2013-01-01

    Full Text Available The arbitrary position control of cylinder has always been the hard challenge in pneumatic system. We try to develop a cylinder position servo control method by combining fuzzy PID with the theoretical model of the proportional valve-controlled cylinder system. The pressure differential equation of cylinder, pressure-flow equation of proportional valve, and moment equilibrium equation of cylinder are established. And the mathematical models of the cylinder driving system are linearized. Then fuzzy PID control algorithm is designed for the cylinder position control, including the detail analysis of fuzzy variables and domain, fuzzy logic rules, and defuzzification. The stability of the proposed fuzzy PID controller is theoretically proved according to the small gain theorem. Experiments for targets position of 250 mm, 300 mm, and 350 mm were done and the results showed that the absolute error of the position control is less than 0.25 mm. And comparative experiment between fuzzy PID and classical PID verified the advantage of the proposed algorithm.

  4. Breached cylinder incident at the Portsmouth gaseous diffusion plant

    Energy Technology Data Exchange (ETDEWEB)

    Boelens, R.A. [Martin Marietta Energy Systems, Inc., Piketon, OH (United States)

    1991-12-31

    On June 16, 1990, during an inspection of valves on partially depleted product storage cylinders, a 14-ton partially depleted product cylinder was discovered breached. The cylinder had been placed in long-term storage in 1977 on the top row of Portsmouth`s (two rows high) storage area. The breach was observed when an inspector noticed a pile of green material along side of the cylinder. The breach was estimated to be approximately 8- inches wide and 16-inches long, and ran under the first stiffening ring of the cylinder. During the continuing inspection of the storage area, a second 14-ton product cylinder was discovered breached. This cylinder was stacked on the bottom row in the storage area in 1986. This breach was also located adjacent to a stiffening ring. This paper will discuss the contributing factors of the breaching of the cylinders, the immediate response, subsequent actions in support of the investigation, and corrective actions.

  5. Organization of Gold Nanorods in Cylinder-Forming Block Copolymer Films

    Science.gov (United States)

    Jian, Guoquian; Riggleman, Robert; Composto, Russell

    2012-02-01

    The addition of gold nanorods (AuNRs) to copolymer films can impart unique optical and electrical properties. To take full advantage of this system, the AuNRs must be dispersed in a self-organizing copolymer that directs the orientation of the anisotropic particle. In the present work, AuNRs with aspect ratio 3.6 (8 nm x 29 nm) are grafted with poly(2-vinyl pyridine) (P2VP) brushes and dispersed in a cylindrical forming diblock copolymer of polystyrene-b-P2VP (180K-b-77K, 29.6 wt% P2VP). Films are spun cast and solvent annealed in chloroform to produce a perpendicular cylindrical morphology at the surface. Using TEM and UV-ozone etching combined with AFM, the AuNRs are well dispersed and co-locate (top down view) with the P2VP cylinders, ˜50nm diameter. However, the AuNRs mainly lie parallel to the surface indicating that they likely locate at the junction created at the intersection between P2VP cylinders and P2VP brush layer adjacent to the silicon oxide surface. Self-consistent field calculations of the Au:PS-b-P2VP morphology as well as the effect of adding P2VP homopolymer to the nanocomposite will be discussed.

  6. Lock-on characteristics behind two side-by-side cylinders of diameter ratio two at small gap ratio

    Science.gov (United States)

    Lee, Petry Y. R.; Lu, Wei-Ting; Chou, Shy-Tsin; Kuo, Cheng-Hsiung

    2012-10-01

    The lock-on characteristics, the detailed interactions and downstream evolutions of the wakes behind side-by-side cylinders of unequal diameter ( D/ d = 2), spaced by a gap ratio 0.75 ( G/ D = 0.75), are investigated at Reynolds number 600 by the dye flow visualization, laser Doppler anemometry (LDA) and particle image velocimeter (PIV) velocity measurements. The lock-on frequency bands are studied by LDA and PIV at Reynolds number 2,000. The D, d and G are the diameters of the large, the small cylinders and the net gap between two cylinders, respectively. Periodic excitations, in form of rotary oscillation about the cylinder center, are applied to the large cylinder with the same amplitude. It is found that while the large cylinder is excited, two lock-on frequency bands of the wake behind the large cylinder are detected. These two lock-on frequency bands correspond to the primary and the one-third sub-harmonic lock-on of the wake behind large cylinder, respectively. These two lock-on frequency bands distribute symmetrically about the fundamental and the third superharmonic of the natural shedding frequency behind a single cylinder at the same Reynolds number. The left-shifted frequency band (1.8 ≤ f e / f os ≤ 2.0) is not considered as a locked-on frequency band because the phase difference between two excitation frequencies across f e / f os = 2.0 vary significantly. While the wake behind the large cylinder is locked-on at f e /3 (or f os ), the gap flow becomes unbiased and the frequency of the wake behind small cylinder remains around the natural shedding frequency. Thus, the frequency band of 3.0 ≤ f e / f os ≤ 3.22 is also not locked-on because the phase difference in the narrow wake excited at f e / f os = 2.93 and 3.07 changes significantly. Note f e and f os denote the excitation frequency and the natural shedding frequency behind a single large cylinder, respectively.

  7. Lock-on characteristics behind two side-by-side cylinders of diameter ratio two at small gap ratio

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Petry Y.R.; Lu, Wei-Ting; Chou, Shy-Tsin; Kuo, Cheng-Hsiung [National Chung Hsing University, Department of Mechanical Engineering, Taichung (China)

    2012-10-15

    The lock-on characteristics, the detailed interactions and downstream evolutions of the wakes behind side-by-side cylinders of unequal diameter (D/d = 2), spaced by a gap ratio 0.75 (G/D = 0.75), are investigated at Reynolds number 600 by the dye flow visualization, laser Doppler anemometry (LDA) and particle image velocimeter (PIV) velocity measurements. The lock-on frequency bands are studied by LDA and PIV at Reynolds number 2,000. The D, d and G are the diameters of the large, the small cylinders and the net gap between two cylinders, respectively. Periodic excitations, in form of rotary oscillation about the cylinder center, are applied to the large cylinder with the same amplitude. It is found that while the large cylinder is excited, two lock-on frequency bands of the wake behind the large cylinder are detected. These two lock-on frequency bands correspond to the primary and the one-third sub-harmonic lock-on of the wake behind large cylinder, respectively. These two lock-on frequency bands distribute symmetrically about the fundamental and the third superharmonic of the natural shedding frequency behind a single cylinder at the same Reynolds number. The left-shifted frequency band (1.8 {<=} f{sub e} /f{sub os} {<=} 2.0) is not considered as a locked-on frequency band because the phase difference between two excitation frequencies across f{sub e} /f{sub os} = 2.0 vary significantly. While the wake behind the large cylinder is locked-on at f{sub e} /3 (or f{sub os}), the gap flow becomes unbiased and the frequency of the wake behind small cylinder remains around the natural shedding frequency. Thus, the frequency band of 3.0 {<=} f{sub e} /f{sub os} {<=} 3.22 is also not locked-on because the phase difference in the narrow wake excited at f{sub e} /f{sub os} = 2.93 and 3.07 changes significantly. Note f{sub e} and f{sub os} denote the excitation frequency and the natural shedding frequency behind a single large cylinder, respectively. (orig.)

  8. Mastication suppresses initial gastric emptying by modulating gastric activity.

    Science.gov (United States)

    Ohmure, H; Takada, H; Nagayama, K; Sakiyama, T; Tsubouchi, H; Miyawaki, S

    2012-03-01

    Because various mastication-related factors influence gastric activity, the functional relationship between mastication and gastric function has not been fully elucidated. To investigate the influence of mastication on gastric emptying and motility, we conducted a randomized trial to compare the effects of mastication on gastric emptying and gastric myoelectrical activity under conditions that excluded the influences of food comminution, taste, and olfaction. A (13)C-acetate breath test with electrogastrography and electrocardiography was performed in 14 healthy men who ingested a test meal with or without chewing gum. Autonomic nerve activity was evaluated by fluctuation analysis of heart rate. Gastric emptying was significantly delayed in the 'ingestion with mastication' group. Gastric myoelectrical activity was significantly suppressed during mastication and increased gradually in the post-mastication phase. A decrease in the high-frequency power of heart rate variability was observed coincidentally with gastric myoelectrical activity suppression. These findings suggest that initial gastric emptying is suppressed by mastication, and that the suppression is caused by mastication-induced inhibition of gastric activity (UMIN Clinical Trial Registration no. UMIN000005351).

  9. Gastric Emptying of Elemental Liquid Diets Versus Semisolid Diets in Bedridden Gastrostomy-fed Patients.

    Science.gov (United States)

    Horiuchi, Akira; Sakai, Ryosei; Tamaki, Michio; Kajiyama, Masashi; Tanaka, Naoki; Morikawa, Akio

    2018-03-21

    Aspiration is a common problem in bedridden gastrostomy-fed patients. We compared gastric emptying of an elemental liquid diet and a commercial semisolid diet in bedridden gastrostomy-fed patients. Study 1: from January 2013 to December 2016, consecutive bedridden patients receiving percutaneous endoscopic gastrostomy (PEG) semisolid feeding hospitalized due to aspiration pneumonia were switched to elemental liquid diet feedings. The frequency of defecation, tube feed contents aspirated from the trachea, and aspiration pneumonia during hospitalization were retrospectively reviewed. Study 2 was a randomized, crossover trial comparing C sodium acetate gastric emptying of a commercial elemental liquid or a commercial semisolid diet in bedridden PEG patients and controls. Study 1: 18 patients were enrolled. Elemental liquid diet was aspirated from the trachea in 1 (5.6%) (once in 24 observations); neither aspiration pneumonia nor diarrhea developed during elemental liquid diet feeding over 2 weeks observation. Study 2: 8 PEG patients and 8 healthy subjects were separately randomized to assess gastric emptying of the commercial elemental and semisolid diets. The elemental liquid diet was associated with a significant decrease of the 10%, 30%, or 50% emptying (excretion) time (Pbedridden PEG patients. They may prevent or reduce aspiration pneumonia compared with semisolid diets.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/.

  10. Effect of itopride on gastric emptying in longstanding diabetes mellitus.

    Science.gov (United States)

    Stevens, J E; Russo, A; Maddox, A F; Rayner, C K; Phillips, L; Talley, N J; Giguère, M; Horowitz, M; Jones, K L

    2008-05-01

    Delayed gastric emptying (GE) occurs in 30-50% of patients with longstanding type 1 or 2 diabetes, and represents a major cause of morbidity. Current therapeutic options are limited. We aimed at evaluating the effects of itopride on GE in patients with longstanding diabetes. Twenty-five patients (20 type 1, 5 type 2; 10 males, 15 females; mean age 45.2 +/- 2.7 years; body mass index 27.5 +/- 0.9 kg m(-2); duration of diabetes 20.2 +/- 2.4 years) were enrolled in a double-blind, placebo-controlled, randomized, crossover trial. Subjects received both itopride (200 mg) and placebo t.i.d. for 7 days, with a washout of 7-14 days. GE (scintigraphy), blood glucose (glucometer) and upper gastrointestinal (GI) symptoms (questionnaire) were measured following each treatment period. The test meal comprised 100 g ground beef (99mTc-sulphur colloid) and 150 mL of 10% dextrose [67Ga-ethylenediaminetetraacetic acid (EDTA)]. There was a slight trend for itopride to accelerate both solid (P = 0.09) and liquid (P = 0.09) GE. With itopride treatment, the emptying of both solids and liquids tended to be more accelerated, as the emptying with placebo was slower (solids: r = 0.39, P = 0.057; liquids: r = 0.44, P itopride modestly accelerated liquid (P Itopride had no effect on mean blood glucose during the GE measurement (placebo: 9.8 +/- 0.6 mmol L(-1) vs itopride: 9.6 +/-0.6 mmol L(-1)), or GI symptoms (placebo: 1.4 +/- 0.4 vs itopride: 1.8 +/- 0.5). Itopride, in a dose of 200 mg t.i.d. for 7 days, tends to accelerate GE of liquids and solids in longstanding diabetes. The magnitude of this effect appears to be modest and possibly dependent on the rate of GE without itopride.

  11. Highly Enriched Uranium Metal Annuli and Cylinders with Polyethylene Reflectors and/or Internal Polyethylene Moderator

    International Nuclear Information System (INIS)

    Tyler Sumner; J. Blair Briggs; Leland Montierth

    2007-01-01

    A variety of critical experiments were constructed of enriched uranium metal during the 1960s and 1970s at the Oak Ridge Critical Experiments Facility in support of criticality safety operations at the Y-12 Plant. The purposes of these experiments included the evaluation of storage, casting, and handling limits for the Y-12 Plant and providing data for verification of calculation methods and cross-sections for nuclear criticality safety applications. These included solid cylinders of various diameters, annuli of various inner and outer diameters, two and three interacting cylinders of various diameters, and graphite and polyethylene reflected cylinders and annuli. Of the hundreds of delayed critical experiments, experiments of uranium metal annuli with and without polyethylene reflectors and with the central void region either empty or filled with polyethylene were evaluated under ICSBEP Identifier HEU-MET-FAST-076. The outer diameter of the uranium annuli varied from 9 to 15 inches in two-inch increments. In addition, there were uranium metal cylinders with diameters varying from 7 to 15 inches with complete reflection and reflection on one flat surface to simulate floor reflection. Most of the experiments were performed between February 1964 and April 1964. Five partially reflected (reflected on the top only) experiments were assembled in November 1967, but are judged by the evaluators not to be of benchmark quality. Twenty-four of the twenty-five experiments have been determined to have fast spectra. The only exception has a mixed spectrum. Analyses were performed in which uncertainty associated with five different parameters associated with the uranium parts and three associated with the polyethylene parts was evaluated. Included were uranium mass, height, diameter, isotopic content, and impurity content and polyethylene mass, diameter, and impurity content. There were additional uncertainties associated with assembly alignment, support structure, and the value

  12. HF DBD plasma actuators for reduction of cylinder noise in flow

    International Nuclear Information System (INIS)

    Kopiev, V F; Kopiev, V A; Zaytsev, M Yu; Kazansky, P N; Moralev, I A

    2017-01-01

    Surface high frequency dielectric barrier discharge (HF DBD) was used to reduce flow-induced noise, radiated by circular cylinder in cross flow. Effect of HF DBD actuators is studied for flow velocity up to 80 m s −1 (Reynolds numbers up to 2.18 · 10 5 ), corresponding to the typical aircraft landing approach speed. Noise measurements were performed by microphone array in anechoic chamber; averaged flow parameters were studied by particle image velocimetry (PIV). Actuator was powered by high-frequency voltage in hundreds kHz range in steady or modulated mode with the modulation frequency of 0.3–20 kHz (Strouhal number St of 0.4 to 20). It is demonstrated that upstream directed plasma actuators are able to reduce the vortex noise of a cylinder by 10 dB. Noise reduction is accompanied by significant reorganization of the wake behind a cylinder, decreasing both wake width and turbulence level. The physical mechanism related to broadband noise control by HF DBD actuator is also discussed. (paper)

  13. Ghrelin stimulates gastric emptying and hunger in normal-weight humans

    DEFF Research Database (Denmark)

    Levin, F; Edholm, T; Schmidt, P T

    2006-01-01

    CONTEXT: Ghrelin is produced primarily by enteroendocrine cells in the gastric mucosa and increases gastric emptying in patients with gastroparesis. MAIN OBJECTIVE: The objective of the study was to evaluate the effect of ghrelin on gastric emptying, appetite, and postprandial hormone secretion i...

  14. Where are kids getting their empty calories? Stores, schools, and fast-food restaurants each played an important role in empty calorie intake among US children during 2009-2010.

    Science.gov (United States)

    Poti, Jennifer M; Slining, Meghan M; Popkin, Barry M

    2014-06-01

    Consumption of empty calories, the sum of energy from added sugar and solid fat, exceeds recommendations, but little is known about where US children obtain these empty calories. The objectives of this study were to compare children's empty calorie consumption from retail food stores, schools, and fast-food restaurants; to identify food groups that were top contributors of empty calories from each location; and to determine the location providing the majority of calories for these key food groups. This cross-sectional analysis used data from 3,077 US children aged 2 to 18 years participating in the 2009-2010 National Health and Nutrition Examination Survey. The empty calorie content of children's intake from stores (33%), schools (32%), and fast-food restaurants (35%) was not significantly different in 2009-2010. In absolute terms, stores provided the majority of empty calorie intake (436 kcal). The top contributors of added sugar and solid fat from each location were similar: sugar-sweetened beverages, grain desserts, and high-fat milk∗ from stores; high-fat milk, grain desserts, and pizza from schools; and sugar-sweetened beverages, dairy desserts, french fries, and pizza from fast-food restaurants. Schools contributed about 20% of children's intake of high-fat milk and pizza. These findings support the need for continued efforts to reduce empty calorie intake among US children aimed not just at fast-food restaurants, but also at stores and schools. The importance of reformed school nutrition standards was suggested, as prior to implementation of these changes, schools resembled fast-food restaurants in their contributions to empty calorie intake. Copyright © 2014 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  15. NGSI: Function Requirements for a Cylinder Tracking System

    International Nuclear Information System (INIS)

    Branney, S.

    2012-01-01

    While nuclear suppliers currently track uranium hexafluoride (UF 6 ) cylinders in various ways, for their own purposes, industry practices vary significantly. The NNSA Office of Nonproliferation and International Security's Next Generation Safeguards Initiative (NGSI) has begun a 5-year program to investigate the concept of a global monitoring scheme that uniquely identifies and tracks UF 6 cylinders. As part of this effort, NGSI's multi-laboratory team has documented the 'life of a UF 6 cylinder' and reviewed IAEA practices related to UF 6 cylinders. Based on this foundation, this paper examines the functional requirements of a system that would uniquely identify and track UF 6 cylinders. There are many considerations for establishing a potential tracking system. Some of these factors include the environmental conditions a cylinder may be expected to be exposed to, where cylinders may be particularly vulnerable to diversion, how such a system may be integrated into the existing flow of commerce, how proprietary data generated in the process may be protected, what a system may require in terms of the existing standard for UF 6 cylinder manufacture or modifications to it and what the limiting technology factors may be. It is desirable that a tracking system should provide benefit to industry while imposing as few additional constraints as possible and still meeting IAEA safeguards objectives. This paper includes recommendations for this system and the analysis that generated them.

  16. Empty Container Logistics

    OpenAIRE

    Jakov Karmelić; Čedomir Dundović; Ines Kolanović

    2012-01-01

    Within the whole world container traffic, the largest share of containers is in the status of repositioning. Container repositioning results from the need for harmonization between the point of empty container accumulation and the point of demand, and waiting time for the availability of the first next transport of cargo. This status of containers on the container market is the consequence of imbalances in the worldwide trade distribution on most important shipping routes. The need for fast a...

  17. Gender Difference of Gastric Emptying in Healthy Volunteers and Patients with Functional Dyspepsia.

    Science.gov (United States)

    Mori, Hideki; Suzuki, Hidekazu; Matsuzaki, Juntaro; Taniguchi, Kanami; Shimizu, Toshiyuki; Yamane, Tsuyoshi; Masaoka, Tatsuhiro; Kanai, Takanori

    2017-01-01

    Delayed gastric emptying is one of the reasons why functional dyspepsia (FD) occurs. The 13C-acetate breath test is widely used to evaluate gastric emptying. Nevertheless, the standard value of 13C-acetate breath test has not taken into account the gender difference of gastric emptying among healthy individuals. The main aim of this study was to readjust the standard value of 13C-acetate breath test in the light of gender differences. In addition, we clarified the prevalence and clinical characteristics of delayed gastric emptying in patients with FD using the modified standard values of 13C-acetate breath test. Fifty-two healthy individuals and 126 patients with patients with FD were enrolled. Gastric emptying was evaluated by the 13C-acetate breath test. The cut-off points of Tmax for the diagnosis of delayed gastric emptying were determined on the basis of results from healthy individuals making a distinction of genders. Gastroesophageal reflux symptoms, dyspeptic symptoms, scores of anxiety and depression, age, body mass index (BMI), smoking and alcohol consumption were compared between the delayed gastric emptying group and the non-delayed gastric emptying group. Since gastric emptying was delayed in healthy women compared with that in healthy men (Tmax, 53.6 ± 19.3 vs. 42.7 ± 16.9 min, p = 0.04), we set the cut-off points of Tmax at 60 min in men and at 75 min in women. In patients with FD, the prevalence of delayed gastric emptying was not different between men and women with the modified standard values of 13C-acetate breath test. (31.0 vs. 27.4%, p = 0.68). BMI was lower in the delayed gastric emptying group than in the non-delayed group among the male patients. Reflux symptoms were more severe in delayed gastric emptying group than in the non-delayed group among the female patients. The standard values of 13C-acetate breath test should be modified bearing the gender difference in mind. It provides us more appropriate information to understand the

  18. Application of gastric emptying imaging in the therapy of functional dyspepsia

    International Nuclear Information System (INIS)

    Wen Qingxiang; Shi Jin; Rong Rong; Wang Hongbing

    2012-01-01

    Objective: To investigate the application of gastric emptying imaging in the therapy of functional dyspepsia (FD) of Spleen deficiency and qi stagnation. Methods: 78 cases of patients with FD were divide into Chinese herbal medicine group (40 cases treated with Chinese herbal medicine of Decoction of invigorating spleen) and Western medicine group (38 cases treated with regulating qi and Domperidone). The gastric emptying imagings were carried out before and after treatment. Results: The gastric emptying imaging results showed that both traditional Chinese Medicine and Western medicine treatments had good curative effects (P<0.01), and the traditional Chinese Medicine was better than that of Wester medicine (P<0.05). Conclusion: Gastric emptying imaging is very useful in observation curative effect of FD treatment. (authors)

  19. 49 CFR 173.428 - Empty Class 7 (radioactive) materials packaging.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Empty Class 7 (radioactive) materials packaging... SHIPPERS-GENERAL REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS Class 7 (Radioactive) Materials § 173.428 Empty Class 7 (radioactive) materials packaging. A packaging which previously contained Class 7 (radioactive...

  20. Theory of interacting dislocations on cylinders.

    Science.gov (United States)

    Amir, Ariel; Paulose, Jayson; Nelson, David R

    2013-04-01

    We study the mechanics and statistical physics of dislocations interacting on cylinders, motivated by the elongation of rod-shaped bacterial cell walls and cylindrical assemblies of colloidal particles subject to external stresses. The interaction energy and forces between dislocations are solved analytically, and analyzed asymptotically. The results of continuum elastic theory agree well with numerical simulations on finite lattices even for relatively small systems. Isolated dislocations on a cylinder act like grain boundaries. With colloidal crystals in mind, we show that saddle points are created by a Peach-Koehler force on the dislocations in the circumferential direction, causing dislocation pairs to unbind. The thermal nucleation rate of dislocation unbinding is calculated, for an arbitrary mobility tensor and external stress, including the case of a twist-induced Peach-Koehler force along the cylinder axis. Surprisingly rich phenomena arise for dislocations on cylinders, despite their vanishing Gaussian curvature.

  1. Gastric emptying and intragastric balloon in obese patients.

    Science.gov (United States)

    Bonazzi, P; Petrelli, M D; Lorenzini, I; Peruzzi, E; Nicolai, A; Galeazzi, R

    2005-01-01

    Intragastric balloons have been proposed to induce weight loss in obese subjects. The consequences of the balloon on gastric physiology remain poorly studied. We studied the influence of an intragastric balloon on gastric emptying in obese patients. 12 patients were included in the study, with BMI (mean +/- SD) of 38.51 +/- 4.32 kg/m2. The balloon was inserted under light anaesthesia and endoscopic control, inflated with 700 ml saline, and removed 6 months later. Body weight and gastric emptying (T1/2 and T lag) using 13C-octanoic acid breath test were monitored before balloon placement, during its permanence and 2 months after removal. Mean weight loss was: 6.2 +/- 2.3 kg after one month; 12.4 +/- 5.8 kg after 3 months; 14.4 +/- 6.6 kg after 6 months and 10.1 +/- 4.3 kg two months after BIB removal. Gastric emptying rates were significantly decreased in the first periods with balloon in place, and returned to pre-implantation values after balloon removal. T1/2 was: 87 +/- 32 min before BIB positioning, 181 +/- 91 min after 1 month, 145 +/- 99 min after 3 months, 104 +/- 50 min after 6 months and 90 +/- 43 min 2 months after removal. T lag was 36 +/- 18 min before BIB positioning, 102 +/- 82 min after 1 month, 77 +/- 53 min after 3 months, 59 +/- 28 min after 6 months and 40 +/- 21 min. 2 months after removal. BIB in obese patients seems to be a good help in following the hypo caloric diet, especially during the first three months when the gastric emptying is slower and the sense of repletion is higher. After this period gastric emptying starts to return to normal and the stomach adapts to BIB loosing efficacy in weight loss.

  2. Post-Soviet emptiness (Vladimir Makanin and Viktor Pelevin

    Directory of Open Access Journals (Sweden)

    Hans Günther

    2013-01-01

    Full Text Available Emptiness is a key word in several post-Soviet Russian novels of the late 1990s. One can find it as well in Vladimir Makanin's “Underground” as in two novels written by Viktor Pelevin, “Generation ‘P’” and “Chapaev and Emptiness”. After the fall of Soviet power Pelevin's cynical hero from “Generation ‘P’” changes from literature into advertising business, and in his novel “Chapaev and Emptiness” the legendary Soviet Civil War hero Chapaev transforms into a preacher of quasi-Buddhist nothingness. Makanin's hero, the writer Petrovich, renounces of his profession in order to work as a watchman in shelters for the homeless. His self-abasement is in accordance with the tradition of kenoticism (derived from the Greek word kenós = empty which played an important part in the history of Russian religious and cultural life. Criticizing the hypermoralism of classical Russian literature Makanin outlines a new image of the writer which is opposed to the Russian literary myth but still propagates moral and religious values. Pelevin's novels which reflect the relativism of postmodern poetics focus on another issue – the blurring of the difference between reality and illusion. In “Generation ‘P’”, mass media and advertising produce deceitful simulacra of reality and in “Chapaev and Emptiness” the deconstruction of Soviet mythology assumes the shape of a nightmare. Unsurprisingly, among the imagery of emptiness Malevich's famous “Black Square” including its numerous equivalents as black holes or all sorts of empty spaces is rather frequent in the three novels. Emptiness may be considered to be a characteristic trait of the atmosphere of the 1990s when Russians felt to live in a cultural vacuum somewhere between state economy and unbridled capitalism, between Soviet order and “post-slave” (Makanin chaos.

  3. Empty 4f states in TmS

    International Nuclear Information System (INIS)

    Wachter, P.; Grioni, M.

    1998-01-01

    The reflectivity of TmS single crystals has been measured between 2 meV and 12 eV at room temperature and at 6 K. Besides 3p 6 -5d interband transitions a plasma edge due to free carriers is observed. In the middle infrared (near 50 meV) two sharp lines are found which are interpreted as transitions from the Fermi level into empty crystal field split 4f 13 states. A Bremsstrahlen isochromat spectroscopy (BIS) measurement supports the assumption that the empty 4f 13 state is close to the Fermi energy. (orig.)

  4. Low-Re flow past an isolated cylinder with rounded corners

    KAUST Repository

    Zhang, Wei

    2016-06-29

    Direct numerical simulation is performed for flow past an isolated cylinder at Re=1,000. The corners of the cylinder are rounded at different radii, with the non-dimensional radius of curvature varying from R+=R/D=0.000 (square cylinder with sharp corners) to 0.500 (circular cylinder), in which R is the corner radius and D is the cylinder diameter. Our objective is to investigate the effect of the rounded corners on the development of the separated and transitional flow past the cylinder in terms of time-averaged statistics, time-dependent behavior, turbulent statistics and three-dimensional flow patterns. Numerical results reveal that the rounding of the corners significantly reduces the time-averaged drag and the force fluctuations. The wake flow downstream of the square cylinder recovers the slowest and has the largest wake width. However, the statistical quantities do not monotonically vary with the corner radius, but exhibit drastic variations between the cases of square cylinder and partially rounded cylinders, and between the latter and the circular cylinder. The free shear layer separated from the R+=0.125 cylinder is the most stable in which the first roll up of the wake vortex occurs furthest from the cylinder and results in the largest recirculation bubble, whose size reduces as R+ further increases. The coherent and incoherent Reynolds stresses are most pronounced in the near-wake close to the reattachment point, while also being noticeable in the shear layer for the square and R+=0.125 cylinders. The wake vortices translate in the streamwise direction with a convection velocity that is almost constant at approximately 80% of the incoming flow velocity. These vortices exhibit nearly the same trajectory for the rounded cylinders and are furthest away from the wake centerline for the square one. The flow past the square cylinder is strongly three-dimensional as indicated by the significant primary and secondary enstrophy, while it is dominated by the

  5. Technetium-99m labelled bran: a new agent for measuring gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Sagar, S.; Grime, J.S.; Little, W.; Patten, M.; Gulliford, P.; Critchley, M.; Bennett, R.; Shields, R. (Royal Liverpool Hospital (UK))

    1983-05-01

    Bran was labelled with sup(99m)Tc-pertechnetate, ingested as part of a normal meal and used to measure gastric emptying in 15 normal subjects and in 15 patients with ulcerative colitis. There was no significant difference between the gastric emptying curves of the normal subjects and the patients, suggesting that rapid gastric emptying does not contribute to diarrhoea in ulcerative colitis.

  6. Self-accelerating parabolic cylinder waves in 1-D

    Energy Technology Data Exchange (ETDEWEB)

    Yuce, C., E-mail: cyuce@anadolu.edu.tr

    2016-11-25

    Highlights: • We find a new class of self-accelerating waves. • We show that parabolic cylinder waves self-accelerates in a parabolic potential. • We discuss that truncated parabolic cylinder waves propagates large distance without almost being non-diffracted in free space. - Abstract: We introduce a new self-accelerating wave packet solution of the Schrodinger equation in one dimension. We obtain an exact analytical parabolic cylinder wave for the inverted harmonic potential. We show that truncated parabolic cylinder waves exhibits their accelerating feature.

  7. Relationships between oesophageal transit and solid and liquid gastric emptying in diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Horowitz, M.; Maddox, A.F.; Wishart, J.M.; Harding, P.E.; Chatterton, B.E.; Shearman, D.J.C. (Royal Adelaide Hospital (Australia))

    1991-04-01

    In 87 randomly selected diabetic patients (67 type 1, 20 type 2) and 25 control subjects, gastric emptying of digestible solid and liquid meals and oesophageal transit of a solid bolus were measured with scintigraphic techniques. Gastrointestinal symptoms, autonomic nerve function and glycaemic control were evaluated in the diabetic patients. Gastric emptying and oesophageal transit were slower (P<0.001) in the diabetic patients compared with the control subjects, and both were delayed in about 40% of them. There was a relatively weak (r=0.32; P<0.01) relationship between solid and liquid gastric emptying, and no significant correlation (r=0.11, NS) between oesophageal transit and gastric emptying of the solid meal. Scores for upper gastrointestinal symptoms and autonomic nerve function correlated weakly (r=0.21; P<0.05) with both oesophageal transit and gastric emptying. Gastric emptying of the liquid meal was slower (P<0.05) in patients with blood glucose concentrations >15 mmol/l. These results indicate that gastric emptying in patients with diabetes mellitus should be assessed by liquid as well as by solid test meals and that oesophageal transit should not be used as a predictor of generalised diabetic gastroenteropathy. (orig.).

  8. Empty calories and phantom fullness

    NARCIS (Netherlands)

    Camps, Guido; Mars, Monica; Graaf, de Kees; Smeets, Paul A.M.

    2016-01-01

    Background: Stomach fullness is a determinant of satiety. Although both the viscosity and energy content have been shown to delay gastric emptying, their relative importance is not well understood. Objective: We compared the relative effects of and interactions between the viscosity and energy

  9. A central site of action for benzamide facilitation of gastric emptying.

    Science.gov (United States)

    Costall, B; Gunning, S J; Naylor, R J; Simpson, K H

    1983-07-22

    Gastric emptying of the fed guinea-pig was measured using a non-invasive X-ray fluoroscopic technique to determine passage from the stomach of polystyrene-coated barium sulphate spheroids. Peripherally administered metoclopramide (0.1-10 mg/kg i.p.), clebopride (1-10 mg/kg i.p.), (-)-sulpiride (40 mg/kg i.p.), haloperidol (1 mg/kg i.p.) and domperidone (1-10 mg/kg i.p.) failed to modify gastric emptying. Stress inhibited emptying, and this was considered to explain the effects of eserine and high dose metoclopramide. Gastric emptying was decreased by peripherally administered atropine (0.5 mg/kg i.p.) and apomorphine (0.1-0.5 mg/kg s.c.); the apomorphine response was antagonised by pretreatment with haloperidol, domperidone, (-)-sulpiride, metoclopramide and clebopride but not by prazosin + propranolol. Gastric emptying was facilitated by intracerebroventricular (i.c.v.) administrations of metoclopramide and clebopride (40, 100 and 200 micrograms) but not by i.c.v. domperidone, haloperidol, fluphenazine or (-)-sulpiride (100, 200 micrograms) and was inhibited by i.c.v. apomorphine (100, 200 micrograms); the response to i.c.v. apomorphine was antagonised by i.c.v. pretreatments with haloperidol, domperidone, (-)-sulpiride, metoclopramide and clebopride (40-50 micrograms). Facilitation of emptying by i.c.v. metoclopramide was prevented by peripheral pretreatment with atropine (0.5 mg/kg i.p.). It is concluded that the actions of apomorphine and metoclopramide/clebopride to respectively inhibit and facilitate gastric emptying may be mediated, at least in part, via central mechanisms. Whilst apomorphine's action may be mediated via dopamine receptor mechanisms, metoclopramide and clebopride act at additional unspecified sites, metoclopramide's action being expressed via cholinergic mechanisms.

  10. Sulfamethizole absorption test for the assessment of gastric emptying. Comparison with scintigraphic method

    Energy Technology Data Exchange (ETDEWEB)

    Hirakawa, K.; Iida, M.; Fuchigami, T.; Murata, S.; Matsumoto, T.; Fujishima, M. [Kyushu Univ., Fukuoka (Japan)

    1995-02-01

    To investigate whether the sulfamethizole absorption test can be applied for the assessment of gastric emptying, the authors measured comparatively plasma sulfamethizole concentration and gastric emptying determined by scintigraphy in 15 subjects. After the ingestion of a solid-liquid meal that contained sulfamethizole and radioisotope (technitium-99m-labelled diethylenetraminepentaacetic acid), the plasma sulfamethizole concentrations were measured every 15 to 60 min up to 180 min. The initial emptying time and the exponential curve in the cumulative reduction of radioactivity were used as indicators of gastric emptying. The initial emptying time was significantly correlated with the sulfamethizole concentration at 15 min after ingestion. A close correlation was observed between the rate of decrease in radioactivity and sulfamethizole concentration at 60 min after ingestion. The sulfamethizole absorption test can be used for the evaluation of gastric motility. Two points of measurement, 15 and 60 min after ingestion, are sufficient to demonstrate the initial and subsequent gastric emptying. 21 refs., 4 figs., 3 tabs.

  11. Application of the exact solution for scattering by an infinite cylinder to the estimation of scattering by a finite cylinder.

    Science.gov (United States)

    Wang, R T; van de Hulst, H C

    1995-05-20

    A new algorithm for cylindrical Bessel functions that is similar to the one for spherical Bessel functions allows us to compute scattering functions for infinitely long cylinders covering sizes ka = 2πa/λ up to 8000 through the use of only an eight-digit single-precision machine computation. The scattering function and complex extinction coefficient of a finite cylinder that is seen near perpendicular incidence are derived from those of an infinitely long cylinder by the use of Huygens's principle. The result, which contains no arbitrary normalization factor, agrees quite well with analog microwave measurements of both extinction and scattering for such cylinders, even for an aspect ratio p = l/(2a) as low as 2. Rainbows produced by cylinders are similar to those for spherical drops but are brighter and have a lower contrast.

  12. Low dose caffeine as a salivary tracer for the determination of gastric water emptying in fed and fasted state: A MRI validation study.

    Science.gov (United States)

    Sager, Maximilian; Jedamzik, Philipp; Merdivan, Simon; Grimm, Michael; Schneider, Felix; Kromrey, Marie-Luise; Hasan, Mahmoud; Oswald, Stefan; Kühn, Jens; Koziolek, Mirko; Weitschies, Werner

    2018-06-01

    Improving our knowledge about human gastrointestinal physiology and its impact on oral drug delivery is crucial for the development of new therapies and effective drug delivery systems. The aim of this study was to develop an in vivo tool to determine gastric emptying of water by administration of a caffeine as a tracer substance followed by subsequent saliva caffeine analysis. For this purpose, 35 mg of caffeine were given to six healthy volunteers after a 10 h overnight together with 240 mL of tap water either on a fasted stomach or 30 min after the high-caloric, high-fat breakfast recommended for bioavailability/bioequivalence (BA/BE) studies. Caffeine was administered in form of an ice capsule in order to omit the contamination of the oral cavity with caffeine. Parallel to saliva sampling, magnetic resonance imaging (MRI) was applied in order to validate this novel approach. After administration of the ice capsule, MRI measurements were performed every 2 min for the first 20 min followed by further measurements after 25, 30, 35, 40, 50 and 60 min. Saliva samples were collected always 1 min after the MRI measurement in supine position in the MRI scanner and continued for further 240 min. The caffeine concentration in saliva was quantified after liquid-liquid extraction by a validated HPLC/MS-MS method. The obtained MRI data revealed a fast emptying of the co-administered water within 10 to 50 min in the fasted state and likewise in the fed state. Salivary caffeine kinetics showed a C max from 150 to 400 ng/mL with a t max from 20 to 90 min. MRI data were normalized by setting the maximum emptied volume to 100% and the salivary caffeine kinetics were normalized by setting C max to 100%. In order to compare the results obtained by the MRI and the saliva method, the normalized data for each volunteer was correlated based on a linear regression. In the fasted state the mean slope for six comparisons was 0.9114 ± 0.1500 and the mean

  13. Evaluation of reproducibility of solid-phase gastric emptying in healthy subjects

    International Nuclear Information System (INIS)

    Roland, J.; Dobbeleir, A.; Vandevivere, J.; Ham, H.R.

    1990-01-01

    Radionuclide gastric emptying studies are performed as a matter of clinical routine. Our aim was to evaluate the inter- and intra-individual variability and the reproducibility of gastric emptying studies in healthy young male volunteers using a single solid-phase, standard meal. The meal consisted of a pancake (500 KJ) tagged with 99m Tc-labeled sulfur colloid and no additional liquid. Continuous acquisitions of gastric activity in anterior projection were taken during 90 min, starting from the onset of the meal. Gastric emptying was evaluated three times in a 3-week period. Five different parameters were evaluated. Our results show that there is important inter- and intra-individual variability in normal volunteers. In spite of this variability, no significant difference between the different series of gastric emptying studies was observed. (orig.)

  14. Measurement of gastric emptying rate in humans. Simplified scanning method

    Energy Technology Data Exchange (ETDEWEB)

    Holt, S.; Colliver, J.; Guram, M.; Neal, C.; Verhulst, S.J.; Taylor, T.V. (Univ. of South Carolina School of Medicine, Columbia (USA))

    1990-11-01

    Simultaneous measurements of the gastric emptying rate of the solid and liquid phase of a dual-isotope-labeled test meal were made using a gamma camera and a simple scintillation detector, similar to that used in a hand-held probe. A simple scanning apparatus, similar to that used in a hand-held scintillation probe, was compared with simultaneous measurements made by a gamma camera in 16 healthy males. A dual-labeled test meal was utilized to measure liquid and solid emptying simultaneously. Anterior and posterior scans were taken at intervals up to 120 min using both a gamma camera and the scintillation probe. Good relative agreement between the methods was obtained both for solid-phase (correlation range 0.92-0.99, mean 0.97) and for liquid-phase data (correlation range 0.93-0.99, mean 0.97). For solid emptying data regression line slopes varied from 0.75 to 1.03 (mean 0.84). Liquid emptying data indicated that slopes ranged from 0.71 to 1.06 (mean 0.87). These results suggested that an estimate of the gamma measurement could be obtained by multiplying the scintillation measurement by a factor of 0.84 for the solid phase and 0.87 for the liquid phase. Correlation between repeat studies was 0.97 and 0.96 for solids and liquids, respectively. The application of a hand-held probe technique provides a noninvasive and inexpensive method for accurately assessing solid- and liquid-phase gastric emptying from the human stomach that correlates well with the use of a gamma camera, within the range of gastric emptying rate in the normal individuals in this study.

  15. Measurement of gastric emptying rate in humans. Simplified scanning method

    International Nuclear Information System (INIS)

    Holt, S.; Colliver, J.; Guram, M.; Neal, C.; Verhulst, S.J.; Taylor, T.V.

    1990-01-01

    Simultaneous measurements of the gastric emptying rate of the solid and liquid phase of a dual-isotope-labeled test meal were made using a gamma camera and a simple scintillation detector, similar to that used in a hand-held probe. A simple scanning apparatus, similar to that used in a hand-held scintillation probe, was compared with simultaneous measurements made by a gamma camera in 16 healthy males. A dual-labeled test meal was utilized to measure liquid and solid emptying simultaneously. Anterior and posterior scans were taken at intervals up to 120 min using both a gamma camera and the scintillation probe. Good relative agreement between the methods was obtained both for solid-phase (correlation range 0.92-0.99, mean 0.97) and for liquid-phase data (correlation range 0.93-0.99, mean 0.97). For solid emptying data regression line slopes varied from 0.75 to 1.03 (mean 0.84). Liquid emptying data indicated that slopes ranged from 0.71 to 1.06 (mean 0.87). These results suggested that an estimate of the gamma measurement could be obtained by multiplying the scintillation measurement by a factor of 0.84 for the solid phase and 0.87 for the liquid phase. Correlation between repeat studies was 0.97 and 0.96 for solids and liquids, respectively. The application of a hand-held probe technique provides a noninvasive and inexpensive method for accurately assessing solid- and liquid-phase gastric emptying from the human stomach that correlates well with the use of a gamma camera, within the range of gastric emptying rate in the normal individuals in this study

  16. Influence of meal weight and caloric content on gastric emptying of meals in man

    International Nuclear Information System (INIS)

    Moore, J.G.; Christian, P.E.; Brown, J.A.; Brophy, C.; Datz, F.; Taylor, A.; Alazraki, N.

    1984-01-01

    This study was designed to assess the relative influence of meal weight and caloric content on gastric emptying of liquid and solid meals in man. A dual radioisotopic method which permits noninvasive and simultaneous measurement of liquid- and solid-phase emptying by external gamma camera techniques was employed. Nine healthy volunteer subjects ingested 50-, 300-, and 900-g lettuce and water meals adjusted to either 68, 208, or 633 kcal with added salad oil. The following observations were made: (1) absolute emptying rates (grams of solid food emptied from the stomach per minute) increased directly and significantly with meal weight; (2) increasing meal total caloric content significantly slowed solid food gastric emptying but did not overcome the enhancing effect of meal weight; and (3) liquid emptying rates were uninfluenced by meal total kcal amount

  17. Influence of meal weight and caloric content on gastric emptying of meals in man

    Energy Technology Data Exchange (ETDEWEB)

    Moore, J.G.; Christian, P.E.; Brown, J.A.; Brophy, C.; Datz, F.; Taylor, A.; Alazraki, N.

    1984-06-01

    This study was designed to assess the relative influence of meal weight and caloric content on gastric emptying of liquid and solid meals in man. A dual radioisotopic method which permits noninvasive and simultaneous measurement of liquid- and solid-phase emptying by external gamma camera techniques was employed. Nine healthy volunteer subjects ingested 50-, 300-, and 900-g lettuce and water meals adjusted to either 68, 208, or 633 kcal with added salad oil. The following observations were made: (1) absolute emptying rates (grams of solid food emptied from the stomach per minute) increased directly and significantly with meal weight; (2) increasing meal total caloric content significantly slowed solid food gastric emptying but did not overcome the enhancing effect of meal weight; and (3) liquid emptying rates were uninfluenced by meal total kcal amount.

  18. Nonlinear bending and collapse analysis of a poked cylinder and other point-loaded cylinders

    International Nuclear Information System (INIS)

    Sobel, L.H.

    1983-06-01

    This paper analyzes the geometrically nonlinear bending and collapse behavior of an elastic, simply supported cylindrical shell subjected to an inward-directed point load applied at midlength. The large displacement analysis results for this thin (R/t = 638) poked cylinder were obtained from the STAGSC-1 finite element computer program. STAGSC-1 results are also presented for two other point-loaded shell problems: a pinched cylinder (R/t = 100), and a venetian blind (R/t = 250)

  19. Dynamics of a thermally driven film climbing the outside of a vertical cylinder.

    Science.gov (United States)

    Smolka, Linda B

    2017-10-01

    The dynamics of a film climbing the outside of a vertical cylinder under the competing effects of a thermally driven surface tension gradient and gravity is examined through numerical simulations of a thin-film model for the film height. The model, including boundary conditions, depends on three parameters, the scaled cylinder radius R[over ̂], the upstream film height h_{∞}, and the downstream precursor film thickness b, and reduces to the model for Marangoni driven film climbing a vertical plate in the limit R[over ̂]→∞. The axisymmetric advancing front displays dynamics similar to that found along a vertical plate where, depending on h_{∞}, the film forms a single Lax shock, an undercompressive double shock, or a rarefaction-undercompressive shock. A linear stability analysis of the Lax shock reveals the number of fingers that form along the contact line increases linearly with cylinder circumference while no fingers form for sufficiently small cylinders (below R[over ̂]≈1.15 when b=0.1). The substrate curvature controls the height of the Lax shock, bounds on h_{∞} that define the three distinct solutions, and the maximum growth rate of contact line perturbations to the Lax shock when R[over ̂]=O(1), whereas the three solutions and the stability of the Lax shock converge to the behavior one observes on a vertical plate when R[over ̂]≥O(10). An energy analysis reveals that the azimuthal curvatures of the base state and perturbation, which arise from the annular geometry of the film, promote instability of the advancing contact line.

  20. Gastric emptying in normal subjects

    DEFF Research Database (Denmark)

    Rasmussen, L.; Oster-Jorgensen, E.; Qvist, N.

    1993-01-01

    that liquid lag phase (min) and was significantly shorter in Phase II than in Phase I (1 vs. 4, P = 0.007). The half emptying time of solid linear phase (min) was reproduced with nearly identical median and range values in the three series (I[1]: 67[51-87]; I[2]: 63[47-80]; 61[47-76]). With meal ingestion......This study was designed to clarify whether a part of the variability in gastric emptying could be ascribed to a relationship between meal ingestion and phase activity of the migrating motor complex and whether reproducibility is increased when meal ingestion takes place in relation to preselected...... characteristics of the migrating motor complex. We examined 12 healthy males, and the design included three examinations, twice with meal ingestion in a duodenal Phase I, and once in a Phase II. The meal consisted of an omelette labelled with 99mTc followed by 150 ml water labelled with 111In. The results showed...

  1. Experimental seismic test of fluid coupled co-axial cylinders

    International Nuclear Information System (INIS)

    Chu, M.L.; Brown, S.J.; Lestingi, J.F.

    1979-01-01

    The dynamic response of fluid coupled coaxial cylindrical shells is of interest to the nuclear industry with respect to the seismic design of the reactor vessel and thermal liner. The experiments described present a series of tests which investigate the effect of the annular clearance between the cylinders (gap) on natural frequency, damping, and seismic response of both the inner and outer cylinders. The seismic input is a time history base load to the flexible fluid filled coaxial cylinders. The outer cylinder is elastically supported at both ends while the inner cylinder is supported only at the base (lower) end

  2. Results of ultrasonic testing evaluations on UF6 storage cylinders

    International Nuclear Information System (INIS)

    Lykins, M.L.

    1997-02-01

    The three site cylinder management program is responsible for the safe storage of the DOE owned UF 6 storage cylinders at PORTS, PGDP and at the K-25 site. To ensure the safe storage of the UF 6 in the cylinders, the structural integrity of the cylinders must be evaluated. This report represents the latest cylinder integrity investigation that utilized wall thickness evaluations to identify thinning due to atmospheric exposure

  3. Scale-space for empty catheter segmentation in PCI fluoroscopic images.

    Science.gov (United States)

    Bacchuwar, Ketan; Cousty, Jean; Vaillant, Régis; Najman, Laurent

    2017-07-01

    In this article, we present a method for empty guiding catheter segmentation in fluoroscopic X-ray images. The guiding catheter, being a commonly visible landmark, its segmentation is an important and a difficult brick for Percutaneous Coronary Intervention (PCI) procedure modeling. In number of clinical situations, the catheter is empty and appears as a low contrasted structure with two parallel and partially disconnected edges. To segment it, we work on the level-set scale-space of image, the min tree, to extract curve blobs. We then propose a novel structural scale-space, a hierarchy built on these curve blobs. The deep connected component, i.e. the cluster of curve blobs on this hierarchy, that maximizes the likelihood to be an empty catheter is retained as final segmentation. We evaluate the performance of the algorithm on a database of 1250 fluoroscopic images from 6 patients. As a result, we obtain very good qualitative and quantitative segmentation performance, with mean precision and recall of 80.48 and 63.04% respectively. We develop a novel structural scale-space to segment a structured object, the empty catheter, in challenging situations where the information content is very sparse in the images. Fully-automatic empty catheter segmentation in X-ray fluoroscopic images is an important and preliminary step in PCI procedure modeling, as it aids in tagging the arrival and removal location of other interventional tools.

  4. Low-Re flow past an isolated cylinder with rounded corners

    KAUST Repository

    Zhang, Wei; Samtaney, Ravi

    2016-01-01

    rounded cylinders, and between the latter and the circular cylinder. The free shear layer separated from the R+=0.125 cylinder is the most stable in which the first roll up of the wake vortex occurs furthest from the cylinder and results in the largest

  5. Effects of different sweet preloads on incretin hormone secretion, gastric emptying, and postprandial glycemia in healthy humans.

    Science.gov (United States)

    Wu, Tongzhi; Zhao, Beiyi R; Bound, Michelle J; Checklin, Helen L; Bellon, Max; Little, Tanya J; Young, Richard L; Jones, Karen L; Horowitz, Michael; Rayner, Christopher K

    2012-01-01

    Macronutrient "preloads" can stimulate glucagon-like peptide 1 (GLP-1) and glucose-dependent insulinotropic polypeptide (GIP), slow gastric emptying, and reduce postprandial glycemic excursions. After sweet preloads, these effects may be signaled by sodium-glucose cotransporter-1 (SGLT1), sweet taste receptors, or both. We determined the effects of 4 sweet preloads on GIP and GLP-1 release, gastric emptying, and postprandial glycemia. Ten healthy subjects were studied on 4 separate occasions each. A preload drink containing 40 g glucose, 40 g tagatose/isomalt mixture (TIM), 40 g 3-O-methylglucose (3OMG; a nonmetabolized substrate of SGLT1), or 60 mg sucralose was consumed 15 min before a (13)C-octanoic acid-labeled mashed potato meal. Blood glucose, plasma total GLP-1 and GIP, serum insulin, and gastric emptying were determined. Both glucose and 3OMG stimulated GLP-1 and GIP release in advance of the meal (each P < 0.05), whereas TIM and sucralose did not. The overall postprandial GLP-1 response was greater after glucose, 3OMG, and TIM than after sucralose (P < 0.05), albeit later after TIM than the other preloads. The blood glucose and insulin responses in the first 30 min after the meal were greatest after glucose (each P < 0.05). Gastric emptying was slower after both 3OMG and TIM than after sucralose (each P < 0.05). In healthy humans, SGLT1 substrates stimulate GLP-1 and GIP and slow gastric emptying, regardless of whether they are metabolized, whereas the artificial sweetener sucralose does not. Poorly absorbed sweet tastants (TIM), which probably expose a greater length of gut to nutrients, result in delayed GLP-1 secretion but not in delayed GIP release. These observations have the potential to optimize the use of preloads for glycemic control. This trial was registered at www.actr.org.au as ACTRN12611000775910.

  6. The Isolation of Nanofibre Cellulose from Oil Palm Empty Fruit Bunch Via Steam Explosion and Hydrolysis with HCl 10%

    Science.gov (United States)

    Gea, S.; Zulfahmi, Z.; Yunus, D.; Andriayani, A.; Hutapea, Y. A.

    2018-03-01

    Cellulose nanofibrils were obtained from oil palm empty fruit bunch using steam explosion and hydrolized with 10% solution of HCl. Steam explosion coupled with acid hydrolysis pretreatment on the oil palm empty fruit bunch was very effective in the depolymerization and defibrillation process of the fibre to produce fibers in nanodimension. Structural analysis of steam exploded fibers was determined by Fourier Transform Infrared (FT-IR) spectroscopy. Thermal stability of cellulose measured using image analysis software image J. Characterization of the fibers by TEM and SEM displayed that fiber diameter decreases with mechanical-chemical treatment and final nanofibril size was 20-30 nm. FT-IR and TGA data confirmed the removal of hemicellulose and lignin during the chemical treatment process.

  7. Tc-99m labeled triethelene tetraamine polysterene resin gastric emptying studies in bulimia patients

    Energy Technology Data Exchange (ETDEWEB)

    Shih Weijen; Castellanos, F.X.; Domstad, P.A.; DeLand, F.H.; Humphries, L.; Digenis, G.A.

    1987-07-01

    To evaluate gastric emptying in patients with bulimia, 20 patients (all women, ranging in age from 12 to 49 years) with upper gastrointestinal symptoms ingested 150-200 ..mu..Ci/sup 99m/ Tc-triethelene tetraamine polysterene resin in cereal and had scintigraphy in the supine position. Data were accumulated at 5 min intervals to determine the gastric emptying time (GET). The results showed that the gastric emptying time was prolonged in 12 patients and decreased in 8. All 12 patients with prolonged emptying time were given 10 mg metoclopramide intravenously; 9 of these had a good response and 3 had no response. Although all patients had subjective symptoms of gastric dysfunction, the results indicate that about 60% had delayed and 40% had rapid gastric emptying. The findings of two extremes of gastric emptying time remain to be explained, however, this enables (Albibi and McCullum 1983) objective documentation of gastric emptying as this technique (American Psychiatric Association 1980) can separate those patients with rapid GET from those with prolonged GET, who might benefit from metoclopramide.

  8. Tc-99m labeled triethelene tetraamine polysterene resin gastric emptying studies in bulimia patients

    International Nuclear Information System (INIS)

    Shih Weijen; Castellanos, F.X.; Domstad, P.A.; DeLand, F.H.; Humphries, L.; Digenis, G.A.

    1987-01-01

    To evaluate gastric emptying in patients with bulimia, 20 patients (all women, ranging in age from 12 to 49 years) with upper gastrointestinal symptoms ingested 150-200 μCi 99m Tc-triethelene tetraamine polysterene resin in cereal and had scintigraphy in the supine position. Data were accumulated at 5 min intervals to determine the gastric emptying time (GET). The results showed that the gastric emptying time was prolonged in 12 patients and decreased in 8. All 12 patients with prolonged emptying time were given 10 mg metoclopramide intravenously; 9 of these had a good response and 3 had no response. Although all patients had subjective symptoms of gastric dysfunction, the results indicate that about 60% had delayed and 40% had rapid gastric emptying. The findings of two extremes of gastric emptying time remain to be explained, however, this enables (Albibi and McCullum 1983) objective documentation of gastric emptying as this technique (American Psychiatric Association 1980) can separate those patients with rapid GET from those with prolonged GET, who might benefit from metoclopramide. (orig.)

  9. Intrauterine growth-restricted piglets have similar gastric emptying rates but lower rectal temperatures and altered blood values when compared with normal-weight piglets at birth

    DEFF Research Database (Denmark)

    Williams, Charlotte Amdi; Klarlund, M. V.; Pedersen, Janni Hales

    2016-01-01

    Intrauterine growth-restricted (IUGR) piglets have lower survival rates and are more likely to have empty stomachs 24 h after birth than normal piglets. Although hypoglycemia may result from low colostrum intake per se, it is not known if slow gastric emptying may be an additional risk factor...... that the gastric emptying rate and blood glucose would be lower in IUGR piglets. We investigated gastric emptying rates in normal and IUGR piglets and blood glucose and rectal temperatures at birth and after 15, 30, 60, and 120 min. In addition, blood parameters relevant for metabolism were studied. Forty......-eight piglets (24 normal and 24 IUGR) were classified at birth as either normal or IUGR on the basis of head morphology. Piglets were removed from the sow at birth before suckling, and birth weight was recorded. Pooled porcine colostrum was tube-fed to all piglets at 12 mL/kg BW as soon as possible after birth...

  10. Label inspection of approximate cylinder based on adverse cylinder panorama

    Science.gov (United States)

    Lin, Jianping; Liao, Qingmin; He, Bei; Shi, Chenbo

    2013-12-01

    This paper presents a machine vision system for automated label inspection, with the goal to reduce labor cost and ensure consistent product quality. Firstly, the images captured from each single-camera are distorted, since the inspection object is approximate cylindrical. Therefore, this paper proposes an algorithm based on adverse cylinder projection, where label images are rectified by distortion compensation. Secondly, to overcome the limited field of viewing for each single-camera, our method novelly combines images of all single-cameras and build a panorama for label inspection. Thirdly, considering the shake of production lines and error of electronic signal, we design the real-time image registration to calculate offsets between the template and inspected images. Experimental results demonstrate that our system is accurate, real-time and can be applied for numerous real- time inspections of approximate cylinders.

  11. Expression, receptor binding, and biophysical characterization of guinea pig insulin desB30

    DEFF Research Database (Denmark)

    Engholm, Ebbe; Hansen, Thomas Hesselhøj; Johansson, Eva

    2015-01-01

    Here we report, for the first time, the heterologous expression of desB30 guinea pig insulin (GI desB30) in the yeast Saccharomyces cerevisiae. The affinities of GI desB30 for the insulin receptor A and the IGF-I receptor were also quantified for the first time. Small-angle X-ray scattering...

  12. Treatment of vomiting and of gastric emptying suppression in primates after gamma irradiation

    International Nuclear Information System (INIS)

    Dubois, A.; Dorval, E.D.; O'Connell, L.; Durakovic, A.; Conklin, J.J.

    1984-01-01

    Total body irradiation is followed within minutes by nausea and vomiting. In dogs, the authors found that gastric emptying was suppressed for at least 3 hours after exposure to 8 Gy Cobalt-60; in addition, pretreatment with domperidone (D) could prevent vomiting without improving gastric emptying. In the present studies, the authors used a primate model to further investigate the possibility of treating radiation induced vomiting and delayed gastric emptying. Gastric emptying was measured using either (1) radionuclide imaging after intragastric administration of chicken liver tagged in vivo with 1 mCi Tc-99m sulfur colloid and water containing 0.2 mCi In-111-DTPA; or (2) a Tc-99 m-DPTA dilution technique. Chair-adapted rhesus monkeys were studied in the basal state receiving either saline (S; 1.0 ml), D (0.1 mg/kg) or metoclopramide (M; 0.15 mg/kg). All monkeys were then exposed to total body irradiation (8 Gy, Cobalt-60) after receiving either S, D or M. Vomiting was observed in 5 of 6 monkeys receiving S or D but in only one of 5 animals pretreated with M. Gastric emptying was unaffected by any drug in the basal state (S: 5.54 +- 0.86; D: 6.21 +- 1.01; P: 6.52 +- 0.95%/min; means +- SE). After irradiation, emptying was completely abolished in animals treated with S (0.2 +- 0.2%/min) or D (0.1 +- 0.1%/min; in contrast, pretreatment with M improved gastric emptying significantly (1.81 +- 0.52%/min. Thus, gastric emptying is suppressed in monkeys who vomit after exposure to total body irradiation. In addition, vomiting is prevented and suppression of gastric emptying is improved by M, a dopamine antagonist that acts centrally but not by D, a peripherally acting dopamine antagonist

  13. A Study of Gas Economizing Pneumatic Cylinder

    International Nuclear Information System (INIS)

    Li, T C; Wu, H W; Kuo, M J

    2006-01-01

    The pneumatic cylinder is the most typical actuator in the pneumatic equipment, and its mechanism is so simple that it is often used to operate point to point driving without the feedback loop in various automatic machines. But, the energy efficiency of pneumatic system is very poor compared with electrical systems and hydraulic systems. So, it is very important to discuss the energy saving for the pneumatic cylinder systems. In this thesis, we proposed three methods to apply the reduction in the air consumed for pneumatic cylinder systems. An air charge accumulator is used to absorb the exhausted compress air and a boost valve boosted the air to the higher pressure for used again. From the experiments, the direct used cylinder exhaust air may save about 40% of compress air

  14. The effects of temperature on gastric emptying time of malabar blood snapper (Lutjanus malabaricus, Bloch & Schneider 1801) using X-radiography technique

    International Nuclear Information System (INIS)

    Mazumder, Sabuj Kanti; Ghaffar, Mazlan Abd.; Das, Simon Kumar

    2015-01-01

    Water temperature can influence the metabolic rate of ectothermal animal such as, fish. This study aims to investigate the gastric emptying time (GET) of malabar blood snapper (L. malabaricus) at different temperature (22, 26, 30, 34°C) fed with commercial diet pellet. The gastric emptying times at different temperatures were determined X-radiographically, using barium sulfate (BaSO 4 ) as a contrast medium food marker. The food marker and X-radiography showed that initial voidance of fecal matter began 4-8 h after feeding at all temperature. The fastest GET (18 h) was obsereved at 30°C, whereas the longest (28 h) GET was seen at 22°C. GET was increased with increasing temperature up to 30°C whereas decreased at extreme (34°C) and stress temperature (22°C). The findings of this study suggest to culture L. malabaricus at 26-30°C with commercial diet pellet as this temperature ranges escalate the faster digestion process which may contribute faster growth rate of this commercially important fish species. Overall, the data obtained from this study may have important consequences for optimization of commercial production of malabar blood snapper

  15. The effects of temperature on gastric emptying time of malabar blood snapper (Lutjanus malabaricus, Bloch & Schneider 1801) using X-radiography technique

    Energy Technology Data Exchange (ETDEWEB)

    Mazumder, Sabuj Kanti, E-mail: sabujsau@gmail.com [School of Environmental and Natural Resource Sciences, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor (Malaysia); Ghaffar, Mazlan Abd., E-mail: magfish05@yahoo.com [Marine Ecosystem Research Centre (EKOMAR), Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor (Malaysia); Institute of Tropical Aquaculture, University of Malaysia Terengganu, 21030 Kuala Terengganu (Malaysia); Das, Simon Kumar, E-mail: skdas-maa@yahoo.com [School of Environmental and Natural Resource Sciences, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor (Malaysia); Marine Ecosystem Research Centre (EKOMAR), Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor (Malaysia)

    2015-09-25

    Water temperature can influence the metabolic rate of ectothermal animal such as, fish. This study aims to investigate the gastric emptying time (GET) of malabar blood snapper (L. malabaricus) at different temperature (22, 26, 30, 34°C) fed with commercial diet pellet. The gastric emptying times at different temperatures were determined X-radiographically, using barium sulfate (BaSO{sub 4}) as a contrast medium food marker. The food marker and X-radiography showed that initial voidance of fecal matter began 4-8 h after feeding at all temperature. The fastest GET (18 h) was obsereved at 30°C, whereas the longest (28 h) GET was seen at 22°C. GET was increased with increasing temperature up to 30°C whereas decreased at extreme (34°C) and stress temperature (22°C). The findings of this study suggest to culture L. malabaricus at 26-30°C with commercial diet pellet as this temperature ranges escalate the faster digestion process which may contribute faster growth rate of this commercially important fish species. Overall, the data obtained from this study may have important consequences for optimization of commercial production of malabar blood snapper.

  16. VISCOSITY ANALYSIS OF EMPTY FRUIT BUNCH (EFB BIO-OIL

    Directory of Open Access Journals (Sweden)

    Z.S. Nazirah

    2013-12-01

    Full Text Available Empty fruit bunches (EFB are one of the solid wastes produced by the palm oil industry, which is increasing rapidly. The aim of this paper is to analyse the viscosity of empty fruit bunch (EFB bio-oil that can be extracted from all solid waste EFB as a sample, and a few processes were executed. The samples underwent two processes, which were pre-treatment and pyrolysis. The pre-treatment involved three processes, namely, cutting, shredding and sieving, which were necessary in order to prepare EFB into a particle size suitable for the reactor. After that, the samples were fed into the feedback reactor as feedstock for the pyrolysis process to produce bio-oil. Once the bio-oil was produced, its viscosity was tested using the Brookfield Viscometer in two conditions: before and after the chemical reaction. The bio-oil was treated by adding 10 ml and 20 ml of acetone respectively through the chemical reaction. The viscosity test was carried out at different temperatures, which were 25°C, 30°C, 35°C, 40°C, 45°C and 50°C respectively. The observed viscosity of the EFB bio-oil varied and was higher as the temperature decreased. In addition, the viscosity of the EFB bio-oil was higher when it reacted chemically with the acetone added. Therefore, the results showed that the chemical reaction with acetone has the potential to increase the viscosity of EFB bio-oil.

  17. Methotrexate-induced intestinal mucositis delays gastric emptying and gastrointestinal transit of liquids in awake rats

    Directory of Open Access Journals (Sweden)

    Pedro M. G. Soares

    2011-03-01

    Full Text Available CONTEXT: Methotrexate and other anticancer agents can induce intestinal mucositis, which is one of the most common limiting factor that prevent further dose escalation of the methotrexate. OBJECTIVES: To evaluate the gastric emptying and gastrointestinal transit of liquids in methotrexate-induced intestinal mucositis. METHODS: Wistar rats received methotrexate (2.5 mg/kg/day for 3 days, subcutaneously or saline. After 1, 3 and 7 days, sections of duodenum, jejunum and ileum were removed for assessment of epithelial damage and myeloperoxidase activity (biochemical marker of granulocyte infiltration. Others rats were pre-treated with methotrexate or saline, gavage-fed after 3 or 7 days with a standard test liquid meal, and sacrificed 10, 20 or 30-min later. Gastric and small intestine dye recoveries were measured by spectrophotometry. RESULTS: After 3 days of methotrexate, there was an epithelial intestinal damage in all segments, with myeloperoxidase activity increase in both in duodenum and ileum. Seven days after methotrexate, we observed a complete reversion of this intestinal damage. There was an increase in gastric dye recoveries after 10, 20, and 30-min post-prandial intervals after 3 days, but not after 7 days, of methotrexate. Intestine dye recoveries were decreased in the first and second segments at 10 min, in the third at 20 min, and in the second and third at 30 min, only after 3 days of methotrexate treatment. CONCLUSION: Methotrexate-induced intestinal mucositis delays gastric emptying and gastrointestinal transit of liquids in awake rats.

  18. Enrichment Assay Methods Development for the Integrated Cylinder Verification System

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Leon E.; Misner, Alex C.; Hatchell, Brian K.; Curtis, Michael M.

    2009-10-22

    International Atomic Energy Agency (IAEA) inspectors currently perform periodic inspections at uranium enrichment plants to verify UF6 cylinder enrichment declarations. Measurements are typically performed with handheld high-resolution sensors on a sampling of cylinders taken to be representative of the facility's entire product-cylinder inventory. Pacific Northwest National Laboratory (PNNL) is developing a concept to automate the verification of enrichment plant cylinders to enable 100 percent product-cylinder verification and potentially, mass-balance calculations on the facility as a whole (by also measuring feed and tails cylinders). The Integrated Cylinder Verification System (ICVS) could be located at key measurement points to positively identify each cylinder, measure its mass and enrichment, store the collected data in a secure database, and maintain continuity of knowledge on measured cylinders until IAEA inspector arrival. The three main objectives of this FY09 project are summarized here and described in more detail in the report: (1) Develop a preliminary design for a prototype NDA system, (2) Refine PNNL's MCNP models of the NDA system, and (3) Procure and test key pulse-processing components. Progress against these tasks to date, and next steps, are discussed.

  19. Enrichment Assay Methods Development for the Integrated Cylinder Verification System

    International Nuclear Information System (INIS)

    Smith, Leon E.; Misner, Alex C.; Hatchell, Brian K.; Curtis, Michael M.

    2009-01-01

    International Atomic Energy Agency (IAEA) inspectors currently perform periodic inspections at uranium enrichment plants to verify UF6 cylinder enrichment declarations. Measurements are typically performed with handheld high-resolution sensors on a sampling of cylinders taken to be representative of the facility's entire product-cylinder inventory. Pacific Northwest National Laboratory (PNNL) is developing a concept to automate the verification of enrichment plant cylinders to enable 100 percent product-cylinder verification and potentially, mass-balance calculations on the facility as a whole (by also measuring feed and tails cylinders). The Integrated Cylinder Verification System (ICVS) could be located at key measurement points to positively identify each cylinder, measure its mass and enrichment, store the collected data in a secure database, and maintain continuity of knowledge on measured cylinders until IAEA inspector arrival. The three main objectives of this FY09 project are summarized here and described in more detail in the report: (1) Develop a preliminary design for a prototype NDA system, (2) Refine PNNL's MCNP models of the NDA system, and (3) Procure and test key pulse-processing components. Progress against these tasks to date, and next steps, are discussed.

  20. Sub-wavelength metamaterial cylinders with multiple dipole resonances

    DEFF Research Database (Denmark)

    Arslanagic, Samel; Breinbjerg, Olav

    2009-01-01

    It has been shown that the sub-wavelength resonances of the individual MTM cylinders also occur for electrically small configurations combining 2 or 4 cylinders. For the 2-and 4-cylinder configurations the overall size is 1/20 and 1/12.5 of the smallest wavelength, respectively. These MTM...... configuration thus offer the possibility for multi-resonant electrically small configurations....

  1. Energy Absorption of Monolithic and Fibre Reinforced Aluminium Cylinders

    NARCIS (Netherlands)

    De Kanter, J.L.C.G.

    2006-01-01

    Summary accompanying the thesis: Energy Absorption of Monolithic and Fibre Reinforced Aluminium Cylinders by Jens de Kanter This thesis presents the investigation of the crush behaviour of both monolithic aluminium cylinders and externally fibre reinforced aluminium cylinders. The research is based

  2. MONOMIALS AND BASIN CYLINDERS FOR NETWORK DYNAMICS.

    Science.gov (United States)

    Austin, Daniel; Dinwoodie, Ian H

    We describe methods to identify cylinder sets inside a basin of attraction for Boolean dynamics of biological networks. Such sets are used for designing regulatory interventions that make the system evolve towards a chosen attractor, for example initiating apoptosis in a cancer cell. We describe two algebraic methods for identifying cylinders inside a basin of attraction, one based on the Groebner fan that finds monomials that define cylinders and the other on primary decomposition. Both methods are applied to current examples of gene networks.

  3. Further studies on stress intensity factors of semi-elliptical cracks in pressurized cylinders

    International Nuclear Information System (INIS)

    Kobayashi, A.S.; Emery, A.F.; Love, W.J.; Jain, A.

    1979-01-01

    The authors have used, in the past, the three-dimensional stress intensity magnification factor, Msub(KS), for a semi-elliptical surface crack in a flat plate with a curvature correction factor, Msub(C), to estimate the stress intensity magnification factor, Msub(K) = Msub(C) x Msub(KS), for unpressurized and pressurized inner semi-elliptical cracks and unpressurized outer semi-elliptical cracks in pressurized and thermally shocked cylinders. Recent papers by Atluri/Kathiresan, Welliot/Labbens/Pellissier-Tanon and McGowan/Raymund, however, showed that while this plate analogy with curvature correction provided reasonable estimates of the stress intensity factors at the deepest crack penetration, it underestimated the stress intensity factors at the cylindrical surface. The source of this discrepancy was traced to the curvature correction factor Msub(C), which was re-evaluated for various crack configurations and cylindrical geometries studied. Using the updated Msub(C) together with the previously derived Msub(KS), stress intensity factor magnification factor, Msub(K), was rederived for: (1) Pressurized and unpressurized inner semi-elliptical cracks of two crack aspects ratios of b/a = 0.2 and 0.98 at crack depth of b/(Rsub(o)-Rsub(i)) = 0.4, 0.6, and 0.8 in pressurized cylinders with outside-to-inside radius ratios of Rsub(o)/Rsub(i) = 3/2, 5/4, 7/6, and 10/9. (2) Unpressurized outer semi-elliptical cracks of two crack aspect ratios of b/a = 0.2 and 0.98 at crack depths of b/(Rsub(o)-Rsub(i)) = 0.4, 0.6, and 0.8 in pressurized cylinders with outside-to-inside radius ratio of Rsub(o)/Rsub(i) = 3/2, 5/4, 7/6, and 10/9. (orig.)

  4. Effects of randomized whey-protein loads on energy intake, appetite, gastric emptying, and plasma gut-hormone concentrations in older men and women.

    Science.gov (United States)

    Giezenaar, Caroline; Trahair, Laurence G; Luscombe-Marsh, Natalie D; Hausken, Trygve; Standfield, Scott; Jones, Karen L; Lange, Kylie; Horowitz, Michael; Chapman, Ian; Soenen, Stijn

    2017-09-01

    Background: Protein- and energy-rich supplements are used widely for the management of malnutrition in the elderly. Information about the effects of protein on energy intake and related gastrointestinal mechanisms and whether these differ between men and women is limited. Objective: We determined the effects of whey protein on energy intake, appetite, gastric emptying, and gut hormones in healthy older men and women. Design: Eight older women and 8 older men [mean ± SEM age: 72 ± 1 y; body mass index (in kg/m 2 ): 25 ± 1] were studied on 3 occasions in which they received protein loads of 30 g (120 kcal) or 70 g (280 kcal) or a flavored water control drink (0 kcal). At regular intervals over 180 min, appetite (visual analog scales), gastric emptying (3-dimensional ultrasonography), and blood glucose and plasma gut-hormone concentrations [insulin, glucagon, ghrelin, cholecystokinin, gastric inhibitory polypeptide (GIP), glucagon-like peptide 1 (GLP-1), and peptide tyrosine tyrosine (PYY)] were measured, and ad libitum energy intake was quantified from a buffet meal (180-210 min; energy intake, appetite, and gastric emptying in the men have been published previously). Results: Energy intake at the buffet meal was ∼80% higher in older men than in older women ( P 0.05). There was no effect of sex on gastric emptying, appetite, gastrointestinal symptoms, glucose, or gut hormones ( P > 0.05). There was a protein load-dependent slowing of gastric emptying, an increase in concentrations of insulin, glucagon, cholecystokinin, GIP, GLP-1, and PYY, and an increase in total energy intake (drink plus meal: 12% increase with 30 g and 32% increase with 70 g; P < 0.001). Energy intake at the buffet meal was inversely related to the stomach volume and area under the curve of hormone concentrations ( P < 0.05). Conclusion: In older men and women, whey-protein drinks load-dependently slow gastric emptying and alter gut hormone secretion compared with a control but have no

  5. In vivo ultrasound and biometric measurements predict the empty body chemical composition in Nellore cattle.

    Science.gov (United States)

    Castilhos, A M; Francisco, C L; Branco, R H; Bonilha, S F M; Mercadante, M E Z; Meirelles, P R L; Pariz, C M; Jorge, A M

    2018-05-04

    Evaluation of the body chemical composition of beef cattle can only be measured postmortem and those data cannot be used in real production scenarios to adjust nutritional plans. The objective of this study was to develop multiple linear regression equations from in vivo measurements, such as ultrasound parameters [backfat thickness (uBFT, mm), rump fat thickness (uRF, mm), and ribeye area (uLMA, cm2)], shrunk body weight (SBW, kg), age (AG, d), hip height (HH, m), as well as from postmortem measurements (composition of the 9th to 11th rib section) to predict the empty body and carcass chemical composition for Nellore cattle. Thirty-three young bulls were used (339 ± 36.15 kg and 448 ± 17.78 d for initial weight and age, respectively). Empty body chemical composition (protein, fat, water, and ash in kg) was obtained by combining noncarcass and carcass components. Data were analyzed using the PROC REG procedure of SAS software. Mallows' Cp values were close to the ideal value of number of independent variables in the prediction equations plus one. Equations to predict chemical components of both empty body and carcass using in vivo measurements presented higher R2 values than those determined by postmortem measurements. Chemical composition of the empty body using in vivo measurements was predicted with R2 > 0.73. Equations to predict chemical composition of the carcass from in vivo measurements showed R2 lower (R2Chemical compounds from components of the empty body of Nellore cattle can be calculated by the following equations: protein (kg) = 47.92 + 0.18 × SBW - 1.46 × uRF - 30.72 × HH (R2 = 0.94, RMSPE = 1.79); fat (kg) = 11.33 + 0.16 × SBW + 2.09 × uRF - 0.06 × AG (R2 = 0.74, RMSPE = 4.18); water (kg) = - 34.00 + 0.55 × SBW + 0.10 × AG - 2.34 × uRF (R2 = 0.96, RMSPE = 5.47). In conclusion, the coefficients of determination (for determining the chemical composition of the empty body) of the equations derived from in vivo measures were higher than those

  6. Effect of solid-meal caloric content on gastric emptying kinetics of solids and liquids.

    Science.gov (United States)

    Urbain, J L; Siegel, J A; Mortelmans, L; van Cutsem, E; van den Maegdenbergh, V; de Roo, M

    1989-08-01

    In this study, we have evaluated the effect of the caloric content of a physiological test meal on the gastric emptying kinetics of solids and liquids. 22 healthy male volunteers were studied in two groups matched for age. After an overnight fast, each volunteer underwent the same test procedure; in the first group (G I), 10 volunteers received a meal consisting of bread, 111In-DTPA water and 1 scrambled egg labeled with 99mTc-labelled sulphur colloid; in the second group (G II) 12 volunteers were given the same meal but with 2 labeled eggs in order to increase the caloric content of the solid phase meal. Simultaneous anterior and posterior images were recorded using a dual-headed gamma camera. Solid and liquid geometric mean data were analyzed to determine the lag phase, the emptying rate and the half-emptying time for both solids and liquids. Solid and liquid gastric half-emptying times were significantly prolonged in G II compared to G I volunteers. For the solid phased, the delay was accounted for by a longer lag phase and a decrease in the equilibrium emptying rate. The emptying rate of the liquid phase was significantly decreased in G II compared to G I. Within each group, no statistically significant difference was observed between solid and liquid emptying rates. We conclude that the caloric content of the solid portion of a meal not only alters the emptying of the solid phase but also affects the emptying of the liquid component of the meal.

  7. Measurement of gastric emptying using isotopic method in diabetes, simple obesity and anorexia nervosa

    International Nuclear Information System (INIS)

    Tomofuji, Yoshinobu

    1988-01-01

    Gastric emptying of technetium labeled liquid meal were studied in 46 non-insulin-dependent diabetics, 7 obese patients, 8 anorexia nervosa patients, and 21 normal subjects. All subjects underwent endoscopy and barium study, and none showed any lesion in upper gastrointestinal tract. T1/2, time at which 50% of meal remained, was used as an indicator of gastric emptying. Eight normal subjects have some epigastric discomforts, and have slightly slower gastric emptying than the remaining 13 subjects. But there was no significant difference in T1/2 between the both groups (53.2±12.8 min vs 45.1±10.9 min). Fourteen diabetics have some epigastric discomforts, and have significantly more slower gastric emptying than the remaining 32 diabetics (T1/2; 67.7±24.6 vs 50.5±17.4, p<0.02). The gastric emptying of 13 diabetics who have three major diabetic complications (retinopathy, nephropathy, and peripheral neuropathy), was significantly more slower than that of 15 diabetics without any complication (T1/2; 68.1±24.6 vs 43.5±14.8, p<0.005). The gastric emptying of simple obesity did not show a fixed pattern, but the emptying of anorexia nervosa was remarkably delayed. These findings indicate that diabetic gastroparesis is common in the presence of the three major complications, and the delayed gastric emptying is associated with post-prandial discomfort in diabetics and anorexia nervosa patients. The measurement of gastric emptying can be useful to evaluate the management and the treatment for diabetes and anorexia nervosa. (author)

  8. Effect of solid-meal caloric content on gastric emptying kinetics of solids and liquids

    International Nuclear Information System (INIS)

    Urbain, J.L.; Mortelmans, L.; Cutsem, E. van; Maegdenbergh, V. van den; Roo, M. de

    1989-01-01

    In this study, we have evaluated the effect of the caloric content of a physiological test meal on the gastric emptying kinetics of solids and liquids. 22 healthy male volunteers were studied in two groups matched for age. After an overnight fast, each volunteer underwent the same test procedure; in the first group (G I), 10 volunteers received a meal consisting of bread, 111 In-DTPA water and 1 scrambled egg labeled with 99m Tc-labelled sulphur colloid; in the second group (G II) 12 volunteers were given the same meal but with 2 labeled eggs in order to increase the caloric content of the solid phase meal. Simultaneous anterior and posterior images were recorded using a dual-headed gamma camera. Solid and liquid geometric mean data were analyzed to determine the lag phase, the emptying rate and the half-emptying time for both solids and liquids. Solid and liquid gastric half-emptying times were significantly prolonged in G II compared to G I volunteers. For the solid phased, the delay was accounted for by a longer lag phase and a decrease in the equilibrium emptying rate. The emptying rate of the liquid phase was significantly decreased in G II compared to G I. Within each group, no statistically significant difference was observed between solid and liquid emptying rates. We conclude that the caloric content of the solid portion of a meal not only alters the emptying of the solid phase but also affects the emptying of the liquid component of the meal. (orig.) [de

  9. Measurement of gastric emptying using isotopic method in diabetes, simple obesity and anorexia nervosa

    Energy Technology Data Exchange (ETDEWEB)

    Tomofuji, Yoshinobu

    1988-12-01

    Gastric emptying of technetium labeled liquid meal were studied in 46 non-insulin-dependent diabetics, 7 obese patients, 8 anorexia nervosa patients, and 21 normal subjects. All subjects underwent endoscopy and barium study, and none showed any lesion in upper gastrointestinal tract. T1/2, time at which 50% of meal remained, was used as an indicator of gastric emptying. Eight normal subjects have some epigastric discomforts, and have slightly slower gastric emptying than the remaining 13 subjects. But there was no significant difference in T1/2 between the both groups (53.2+-12.8 min vs 45.1+-10.9 min). Fourteen diabetics have some epigastric discomforts, and have significantly more slower gastric emptying than the remaining 32 diabetics (T1/2; 67.7+-24.6 vs 50.5+-17.4, p<0.02). The gastric emptying of 13 diabetics who have three major diabetic complications (retinopathy, nephropathy, and peripheral neuropathy), was significantly more slower than that of 15 diabetics without any complication (T1/2; 68.1+-24.6 vs 43.5+-14.8, p<0.005). The gastric emptying of simple obesity did not show a fixed pattern, but the emptying of anorexia nervosa was remarkably delayed. These findings indicate that diabetic gastroparesis is common in the presence of the three major complications, and the delayed gastric emptying is associated with post-prandial discomfort in diabetics and anorexia nervosa patients. The measurement of gastric emptying can be useful to evaluate the management and the treatment for diabetes and anorexia nervosa. (author).

  10. National Survey of Radionuclide Gastric Emptying Studies

    Directory of Open Access Journals (Sweden)

    A House

    1997-01-01

    Full Text Available A survey was mailed to all institutions in Canada licensed to use radiopharmaceuticals. Questions addressed meal type; mode of preparation; and means, ranges and SD of emptying times. Seventy-eight per cent of 222 facilities responded, including all 55 teaching centres. Eighty-five per cent of teaching and 56% of nonteaching centres perform solid phase gastric emptying studies (GES. The majority use 99mTc sulphur colloid (Tc-SC added to eggs before cooking as the standard meal. Twenty-five per cent of teaching and 21% of nonteaching centres perform liquid phase GES. Most use a watery solution of 111In-diethylenetriamine pentaacetic acid. Gastric emptying for solid phase GES, expressed as time for 50% emptying (mean t½, varied from 42 to 105 mins for centres using the Tc-SC egg meal. Twenty-eight per cent of teaching centres used ±2 SD to define their normal range, 26% used ±1 SD, 6% used ±1.5 SD, and 40% did not know the number of SD used. Twenty per cent of non-teaching centres used ±2 SD, 12% used ±1 SD and 68% did not know how many SD were used. For liquid phase GES, mean t½ varied from 20 to 60 mins. Eighteen per cent of centres used healthy volunteers to establish or validate normal ranges. There is substantial variability among the normal ranges for radionuclide solid and liquid phase GES in both teaching and nonteaching centres across Canada. A minority of facilities have established or validated their own normal ranges in healthy volunteers. There is a need for a more standardized protocol and range of normal, with internal validation by each institution.

  11. Imperfection effects on the buckling of hydrostatically loaded cylinders

    DEFF Research Database (Denmark)

    Pinna, Rodney; Madsen, Søren

    2015-01-01

    imperfection sensitivity. Work on cylinders with other loading conditions, such as hydrostatic loading, is more limited. Similarly, there is limited work on cylinders with boundary conditions other than simply-supported ends. This paper looks at the case of cylinders under hydrostatic load, which is often...

  12. Dynamic Measurement of Extra Long Stroke Cylinder in the Pneumatic System

    International Nuclear Information System (INIS)

    Chang Ho; Lan Chouwei; Chen, L-C

    2006-01-01

    This paper sets up the measure and control system of the dynamic characteristics of the extra long stroke cylinder. In the different types of the control conditions (e.g. different control law, operating pressure and direct control valves), using the measure and control system to measure the relation between the pressure and the velocity of the motion of the long stroke cylinder and to observe the stick slip phenomenon of the motion of the long stroke cylinder. In the innovate measurement system, two pressure sensors are set on the long stroke cylinder to measure the difference of the pressure between the inlet and the exhaust of the long stroke cylinder. In additions, a draw line encoder is set on the system to measure the position and the velocity of the motion of the long stroke cylinder. The measuring data of the measure system is transferred to the computer via A/D interface card and counter card, and Home-made program of Haptic Interface Device is used to control the system, saving the data of the motion of the long stroke cylinder. The system uses different types of direction control valve to control the motion of the long stroke cylinder and compares the difference of the motion of the long stroke cylinder. The results show that the motion of the cylinder that pauses in the middle of the cylinder stroke and causes the stick slip phenomenon is more violent than the stick slip phenomenon in other position. When the length of the pause time reaches the some range, the acceleration of the motion of the cylinder will be rised substantially. This paper not only focuses on the testing method of the dynamic characteristics of the motion of the long stroke cylinder, but also includes the analysis of the dynamic characteristics of the motion of the long stroke cylinder. It provides the data of the dynamic characteristics of the motion of the long stroke cylinder to improve and design the pneumatic system of the long stroke cylinder

  13. Inner and outer cylinders of the CMS vacuum tank.

    CERN Multimedia

    Patrice Loïez

    2002-01-01

    The vacuum tank of the CMS magnet system consists of inner and outer stainless-steel cylinders and houses the superconducting coil. The inner cylinder contains all the barrel sub-detectors, which it supports via a system of horizontal rails. The cylinder is pictured here in the vertical position on a yellow platform mounted on the ferris-wheel support structure. This will allow it to be pivoted and inserted into the already installed outer cylinder, through which this photo was taken.

  14. Flow past two tandem square cylinders vibrating transversely in phase

    International Nuclear Information System (INIS)

    Mithun, M G; Tiwari, Shaligram

    2014-01-01

    Numerical investigations have been carried out to study the wake characteristics of flow past two tandem square cylinders vibrating in phase. Both the cylinders vibrate in a transverse direction, i.e., perpendicular to the incoming flow with the same frequency and amplitude. The frequency of vibration of the cylinders and the inter-cylinder spacing are varied for fixed values of the Reynolds number (Re = 100) and the amplitude ratio (A/D = 0.4). The synchronous or lock-in regime for the oscillatory wake of the vibrating cylinders has been identified by varying the frequency of the vibration from f e  = 0.4 f 0 to 1.6 f 0 (f 0 being the frequency of vortex shedding behind a stationary square cylinder). The characteristics of lift and drag and the mechanism of vortex shedding are studied by varying the excitation frequency within the lock-in range for each value of inter-cylinder spacing. The complex interaction of flow between the cylinders gives rise to a variety of characteristically different shedding patterns in their wake. For values of inter-cylinder spacing equal to 2D and 3D, periodic, as well as quasi-periodic, lock-in behaviors are observed in the synchronous range. (paper)

  15. Rotation induced flow suppression around two tandem circular cylinders at low Reynolds number

    Energy Technology Data Exchange (ETDEWEB)

    Chatterjee, Dipankar [Advanced Design and Analysis Group, CSIR—Central Mechanical Engineering Research Institute, Durgapur-713209 (India); Gupta, Krishan [Department of Mechanical Engineering, Sardar Vallabhai National Institute of Technology Surat, Surat-395007 (India); Kumar, Virendra [Department of Mechanical Engineering, Indian Institute of Technology Patna, Patna-800013 (India); Varghese, Sachin Abraham, E-mail: d_chatterjee@cmeri.res.in [Department of Mechanical Engineering, National Institute of Technology Durgapur, Durgapur-713209 (India)

    2017-08-15

    The rotation to a bluff object is known to have a stabilizing effect on the fluid dynamic transport around the body. An unsteady periodic flow can be degenerated into a steady flow pattern depending on the rate of rotation imparted to the body. On the other hand, multiple bodies placed in tandem arrangement with respect to an incoming flow can cause destabilization to the flow as a result of the complicated wake interaction between the bodies. Accordingly, the spacing between the bodies and the rate of rotation have significant impact on the overall fluid dynamic transport around them. The present work aims to understand how these two competing factors are actually influencing the fluidic transport across a pair of identical rotating circular cylinders kept in tandem arrangement in an unconfined medium. The cylinders are subjected to a uniform free stream flow and the gaps between the cylinders are varied as 0.2, 0.7, 1.5 and 3.0. Both the cylinders are made to rotate in the clockwise sense. The Reynolds number based on the free stream flow is taken as 100. A two-dimensional finite volume based transient computation is performed for a range of dimensionless rotational speeds of the cylinders (0 ≤ Ω ≤ 2.75). The results show that the shedding phenomena can be observed up to a critical rate of rotation (Ω{sub cr}) depending on the gap spacing. Beyond Ω{sub cr}, the flow becomes stabilized and finally completely steady as Ω increases further. Increasing the gap initially causes a slight decrease in the critical rotational speed, however, it increases at a rapid rate for larger gap spacing. (paper)

  16. Evaluation of gastric emptying function in clinical practice.

    Science.gov (United States)

    Poitras, P; Picard, M; Déry, R; Giguère, A; Picard, D; Morais, J; Plourde, V; Boivin, M

    1997-11-01

    In this retrospective analysis, we compared different methods to evaluate gastric emptying function, aiming to improve the sensitivity and the clinical availability of our diagnostic testing. In the first study, we compared, in 72 patients clinically suspected of gastroparesis, the emptying of a meal containing two solid nutrients with different disintegration rates: 111In-labeled scrambled eggs and 99Tc-labeled liver cubes. Gastric emptying of 111In-labeled egg was delayed in 12 of our patients and the evacuation of the 99Tc-labeled liver was prolonged in 19 patients. The choice of the nutrient was not important for the identification of diabetic gastroparesis (43% vs 57%; NS), but it was determinant in the case of patients suspected of idiopathic gastroparesis (12% were positive with the egg and 25% with the liver; P egg as a radiolabeled tracer in order to improve the sensitivity of the test for detection of gastroparesis; and (2) the radiological detection of radiopaque markers is a reliable and convenient method for the detection of gastroparesis in clinical practice. It is possibly more sensitive than scintigraphy.

  17. 76 FR 38697 - High Pressure Steel Cylinders From China

    Science.gov (United States)

    2011-07-01

    ... imports from China of high pressure steel cylinders, provided for in subheading 7311.00.00 of the... threatened with material injury by reason of LTFV and subsidized imports of high pressure steel cylinders... contained in USITC Publication 4241 (July 2011), entitled High Pressure Steel Cylinders from China...

  18. Modeling flow for modified concentric cylinder rheometer geometry

    Science.gov (United States)

    Ekeruche, Karen; Connelly, Kelly; Kavehpour, H. Pirouz

    2016-11-01

    Rheology experiments on biological fluids can be difficult when samples are limited in volume, sensitive to degradation, and delicate to extract from tissues. A probe-like geometry has been developed to perform shear creep experiments on biological fluids and to use the creep response to characterize fluid material properties. This probe geometry is a modified concentric cylinder setup, where the gap is large and we assume the inner cylinder rotates in an infinite fluid. To validate this assumption we perform shear creep tests with the designed probe on Newtonian and non-Newtonian fluids and vary the outer cylinder container diameter. We have also created a numerical model based on the probe geometry setup to compare with experimental results at different outer cylinder diameters. A creep test is modeled by applying rotation to the inner cylinder and solving for the deformation of the fluid throughout the gap. Steady state viscosity values are calculated from creep compliance curves and compared between experimental and numerical results.

  19. 14 CFR 23.29 - Empty weight and corresponding center of gravity.

    Science.gov (United States)

    2010-01-01

    ... gravity. 23.29 Section 23.29 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Flight General § 23.29 Empty weight and corresponding center of gravity. (a) The empty weight and corresponding center of gravity must be determined by weighing the airplane with— (1) Fixed ballast; (2...

  20. [Gastric emptying of a solid-liquid meal in gastroesophageal reflux in adults].

    Science.gov (United States)

    Bost, R; Hostein, J; Gignoux, C; Busquet, G; Lachet, B; Fournet, J

    1986-04-01

    Several studies concerning the relationships between gastroesophageal reflux (GOR), gastric emptying and esophageal motility are available. So far, results have been contradictory. The purpose of this work was to study gastric emptying in patients with GOR; to search for simultaneous esophageal motility disorders and to specify their type and frequency; to establish a potential relationship between motor disorders of the esophagus and the stomach in these patients. Thirty-two consecutive patients were selected according to clinical criteria, i.e. presence of at least two of the three characteristic symptoms of GOR, and the data of a three-hour post-prandial pH-metry. Gastric stasis related clinical manifestations (nausea, post-prandial vomiting, sensation of abdominal distension or of post-prandial epigastric fullness) were also searched for in all patients. A gastroscopy allowed to score esophagitis in each case. All patients, including adult controls underwent an esophageal manometry as well as a radionuclide determination of gastric emptying, after isotopic labelling of the solid (S) and liquid (L) phases of a test meal. The results showed that there was no significant modification of gastric emptying of the S and L phases of the meal in the group of patients with GOR whatever the intensity of the reflux, judged on the pH-metry results and the endoscopic data. Thus the average time of gastric half-emptying of S and L was respectively 115 and 52 min for the patients vs 111 and 51 min for the control group. As well, no correlation was found between the gastric emptying parameters and the presence or absence of clinical signs of gastric stasis or the amplitude of esophageal contraction waves. On an individual basis, two patients showed a significant decrease in gastric emptying of either the S or L phases without any attendant modification in the kinetics of the other. These results suggest that, in the adult, gastric emptying cannot be considered to be a

  1. Gastric emptying rate in the elderly: implications for drug therapy

    International Nuclear Information System (INIS)

    Evans, M.A.; Triggs, E.J.; Cheung, M.; Broe, G.A.; Creasey, H.

    1981-01-01

    The effect of the aging process on gastric emptying was studied in 11 elderly subjects (mean age, 77) and in 7 young healthy volunteers (mean age, 26). Gastric emptying rates were assessed by a modified sequential scinti-scanning technique after administration of the nonabsorbable chelated radiopharmaceutical 99mTc-DTPA. The rate of emptying, expressed as half-time (T 1/2e) in minutes, was significantly longer (p less than 0.001) in the elderly subjects (mean apparent T 1/2e . 123.23 min) compared to the young healthy volunteers (mean apparent T 1/2e . 49.69 min). Clinical implications of these findings are discussed, particularly with respect to the rate and extent of drug absorption in elderly persons

  2. Natural convection heat transfer on two horizontal cylinders in liquid sodium

    Energy Technology Data Exchange (ETDEWEB)

    Hata, K.; Shiotsu, M.; Takeuchi, Y. [Institute of Atomic Energy, Kyoto Univ. (Japan)] [and others

    1995-09-01

    Natural convection heat transfer on two horizontal 7.6 mm diameter test cylinders assembled with the ratio of the distance between each cylinder axis to the cylinder diameter, S/D, of 2 in liquid sodium was studied experimentally and theoretically. The heat transfer coefficients on the cylinder surface due to the same heat inputs ranging from 1.0 X 10{sup 7} to 1.0 x 10{sup 9} W/m{sup 3} were obtained experimentally for various setting angeles, {gamma}, between vertical direction and the plane including both of these cylinder axis over the range of zero to 90{degrees}. Theoretical equations for laminar natural convection heat transfer from the two horizontal cylinders were numerically solved for the same conditions as the experimental ones considering the temperature dependence of thermophysical properties concerned. The average Nusselt numbers, Nu, values on the Nu versus modified Rayleigh number, R{sub f}, graph. The experimental values of Nu for the upper cylinder are about 20% lower than those for the lower cylinder at {gamma} = 0{degrees} for the range of R{sub f} tested here. The value of Nu for the upper cylinder becomes higher and approaches that for the lower cylinder with the increase in {gamma} over range of 0 to 90{degrees}. The values of Nu for the lower cylinder at each {gamma} are almost in agreement with those for a single cylinder. The theoretical values of Nu on two cylinders except those for R{sub f}<4 at {gamma} = 0{degrees} are in agreement with the experimental data at each {gamma} with the deviations less than 15%. Correlations for Nu on the upper and lower cylinders were obtained as functions of S/D and {gamma} based n the theoretical solutions for the S/D ranged over 1.5 to 4.0.

  3. Empty sella syndrome associated with hormone deficiency in adults

    International Nuclear Information System (INIS)

    Oleaga, L.; Paja, M.; Goni, F.; Grande, J.; Grande, D.; Merino, M.; Delgado, A.

    1999-01-01

    The objective of this study was to correlate the magnetic resonance (MR) images in patients with hormone deficiencies with the clinical data and the hormonal status. We studied 11 cases ef empty sella with different peripheral pituitary deficiencies. Hormone levels were determined according to standard laboratory methods. All the patients underwent MR imaging. The studies were carried out with a 1 Tesla superconducting magnet, using the cranial cavity for transmission and reception. Segittal and coronal T1-weighted spin-echo sequences (TR/TE: 600/15 ms), axial T2-weighted spin-echo sequences (TR/TE: 3,500/19/93 ms) and gadolinium-enhanced (=.2 cc/kg body weight) sagital and coronal T1-weighted spin-echo sequences (TR/TE: 600/15 ms) were employed. Six of the patients presented partial or total hypopituitarism associated with the syndrome of inappropriate antidiuretic hormone secretion (SIADH); there was one case of panhypopituitarism without SIADH and four cases of primary hypothyroidism, there of which were associated with pituitary deficiency, MR imaging revealed five cases of partially empty sella with residual pituitary gland on the sella floor and six cases in which the sella was completely empty. This study also identified six cases of normally situated neurohypophysis, another four in which the neurohypophysis could not be identified and one case of ectopic neurohypophysis. MR imaging is the technique of choice in the study of abnormal hypothalamic-pituitary activity. Empty and partially empty sella should be included among the frequent causes of hypopituitarism, although there is no clear relationship between the degree of adenohypophyseal insufficiency and the degree of atrophy of this system as viewed in MR images. In some cases, this entity may be the radiological sign of a phase in the development of an autoimmune inflammatory process involving the pituitary gland. (Author) 16 refs

  4. Technegas - A new radiopharmaceutical for the measurement of gastric emptying in normal subjects

    Energy Technology Data Exchange (ETDEWEB)

    Kwiatek, M.A.; Jones, K.L. [University of South Australia, SA (Australia). School of Medical Radiation; Burch, W. [Tetley Medical, Lucas Heights, NSW (Australia); Horowitz, M.; Bartholomeusz, F.D.L. [Royal Adelaide Hospital, Adelaide, SA (Australia)

    1998-06-01

    Full text: Scintigraphy is now used widely to measure gastric emptying in humans. Both solid and liquid emptying should ideally be measured - most techniques employ test meals of minced beef and eggs. These meals are not always suitable for patients, especially those observing strict dietary regimens or vegetarians, in whom a vegetable-based meal such as rice is likely to be more acceptable. A previous study attempted to label rice with pertechnetate, but label stability was inadequate. The aim of this study was to determine whether Technegas could be used as a radioisotopic marker to assess gastric emptying of rice and liquids. The stability of Technegas rice was evaluated for three brands of rice by incubation in 0.9% saline, 1M HCI and simulated gastric fluid (3.2g/l pepsinogen, pH 2-4). The labelling stability of each type of rice after four hours was greater than 80%. Gastric emptying of 200g (370kcal) rice and 300ml (300kcal) dextrose drink, both labelled with approximately 20MBq of Technegas, was measured in eight normal subjects (6M, 2F) on two separate days. Venous blood samples were obtained for three hours after ingestion of the meal to quantify intestinal absorption of the radiolabel. Gastric emptying of rice was characterised by a lag phase followed by a linear emptying phase, while emptying of dextrose approximated a linear pattern after a short lag phase. The lag phase was longer for rice than dextrose (25{+-}7min vs 4{+-}2min; P<0.05), but there was no difference in the post lag emptying rate (2.1{+-}0.3kca/min vs 1.7{+-}0.2kcal/min; P=0.2), between the two meals. Intestinal absorption of the radiolabel increased over time, with a plateau after two hours; the total amount absorbed (5.3{+-}13% rice and 6.7{+-}1.8% dextrose) was small. These observations indicate that Technegas labelled rice and dextrose are suitable test meals for measurement of gastric emptying of solids and nutrient containing liquids

  5. Polyglandular autoimmune syndrome iii with hypoglycemia and association with empty sella and hypopituitarism

    Directory of Open Access Journals (Sweden)

    Samia Abdulla Bokhari

    2017-01-01

    Full Text Available A 25-year-old Saudi female with a known case of autoimmune thyroiditis presented to the Emergency Room in stuporous condition. A blood test revealed a blood sugar level of 1.7 mmols/l (30.6 mg/dl. The patient was resuscitated with intravenous glucose. Further evaluations of the patient revealed celiac disease and idiopathic thrombocytopenia with preexisting autoimmune thyroiditis (polyglandular autoimmune syndrome III [PAS III]. The severe hypoglycemia, coupled with 6 years of infertility evaluation, revealed a rare association of empty sella syndrome with hypopituitarism {PAS II}.

  6. Carbon fiber reinforced hierarchical orthogrid stiffened cylinder: Fabrication and testing

    Science.gov (United States)

    Wu, Hao; Lai, Changlian; Sun, Fangfang; Li, Ming; Ji, Bin; Wei, Weiyi; Liu, Debo; Zhang, Xi; Fan, Hualin

    2018-04-01

    To get strong, stiff and light cylindrical shell, carbon fiber reinforced hierarchical orthogrid stiffened cylinders are designed and fabricated. The cylinder is stiffened by two-scale orthogrid. The primary orthogrid has thick and high ribs and contains several sub-orthogrid cells whose rib is much thinner and lower. The primary orthogrid stiffens the bending rigidity of the cylinder to resist the global instability while the sub-orthogrid stiffens the bending rigidity of the skin enclosed by the primary orthogrid to resist local buckling. The cylinder is fabricated by filament winding method based on a silicone rubber mandrel with hierarchical grooves. Axial compression tests are performed to reveal the failure modes. With hierarchical stiffeners, the cylinder fails at skin fracture and has high specific strength. The cylinder will fail at end crushing if the end of the cylinder is not thickened. Global instability and local buckling are well restricted by the hierarchical stiffeners.

  7. A characteristic analysis of the fluidic muscle cylinder

    Science.gov (United States)

    Kim, Dong-Soo; Bae, Sang-Kyu; Hong, Sung-In

    2005-12-01

    The fluidic muscle cylinder consists of an air bellows tube, flanges and lock nuts. It's features are softness of material and motion, simplicity of structure, low production cost and high power efficiency. Recently, unlikely the pneumatic cylinder, the fluidic muscle cylinder without air leakage, stick slip, friction, and seal was developed as a new concept actuator. It has the characteristics such as light weight, low price, high response, durable design, long life, high power, high contraction, which is innovative product fulfilling RT(Robot Technology) which is one of the nation-leading next generation strategy technologies 6T as well as cleanness technology. The application fields of the fluidic muscle cylinder are so various like fatigue tester, brake, accelerator, high technology testing device such as driving simulator, precise position, velocity, intelligent servo actuator under special environment such as load controlling system, and intelligent robot. In this study, we carried out the finite element modeling and analysis about the main design variables such as contraction ration and force, diameter increment of fluidic muscle cylinder. On the basis of finite element analysis, the prototype of fluidic muscle cylinder was manufactured and tested. Finally, we compared the results between the test and the finite element analysis.

  8. Effect of proximal vagotomy and Roux-en-Y diversion on gastric emptying kinetics in asymptomatic patients.

    Science.gov (United States)

    Urbain, J L; Penninckx, F; Siegel, J A; Vandenborre, P; Van Cutsem, E; Vandenmaegdenbergh, V; De Roo, M

    1990-10-01

    The role of the distal stomach in gastric emptying was studied. Ten patients with proximal gastric vagotomy (PV) and 10 age-matched patients with Roux-en-Y gastro-jejunostomy (R-Y) were compared with 10 healthy controls. Gastric emptying of solids and liquids was determined by the use of Tc-99m SC scrambled eggs and In-111 DTPA. In PV, gastric emptying of both solids and liquids was delayed; the prolongation with solids was mainly accounted for by an abnormal lag phase. In R-Y patients, no lag phase was observed, and the solid emptying curve pattern was characterized by early rapid emptying followed by very slow emptying. Both the solid and liquid phases were prolonged. The lag phase is affected by proximal vagotomy and is mainly determined by the distal stomach, which appears to be essential for normal emptying.

  9. Effect of proximal vagotomy and Roux-en-Y diversion on gastric emptying kinetics in asymptomatic patients

    International Nuclear Information System (INIS)

    Urbain, J.L.; Penninckx, F.; Siegel, J.A.; Vandenborre, P.; Van Cutsem, E.; Vandenmaegdenbergh, V.; De Roo, M.

    1990-01-01

    The role of the distal stomach in gastric emptying was studied. Ten patients with proximal gastric vagotomy (PV) and 10 age-matched patients with Roux-en-Y gastro-jejunostomy (R-Y) were compared with 10 healthy controls. Gastric emptying of solids and liquids was determined by the use of Tc-99m SC scrambled eggs and In-111 DTPA. In PV, gastric emptying of both solids and liquids was delayed; the prolongation with solids was mainly accounted for by an abnormal lag phase. In R-Y patients, no lag phase was observed, and the solid emptying curve pattern was characterized by early rapid emptying followed by very slow emptying. Both the solid and liquid phases were prolonged. The lag phase is affected by proximal vagotomy and is mainly determined by the distal stomach, which appears to be essential for normal emptying

  10. Effect of proximal vagotomy and Roux-en-Y diversion on gastric emptying kinetics in asymptomatic patients

    Energy Technology Data Exchange (ETDEWEB)

    Urbain, J.L.; Penninckx, F.; Siegel, J.A.; Vandenborre, P.; Van Cutsem, E.; Vandenmaegdenbergh, V.; De Roo, M. (Univ. Hospital Gasthuisberg, Leuven (Belgium))

    1990-10-01

    The role of the distal stomach in gastric emptying was studied. Ten patients with proximal gastric vagotomy (PV) and 10 age-matched patients with Roux-en-Y gastro-jejunostomy (R-Y) were compared with 10 healthy controls. Gastric emptying of solids and liquids was determined by the use of Tc-99m SC scrambled eggs and In-111 DTPA. In PV, gastric emptying of both solids and liquids was delayed; the prolongation with solids was mainly accounted for by an abnormal lag phase. In R-Y patients, no lag phase was observed, and the solid emptying curve pattern was characterized by early rapid emptying followed by very slow emptying. Both the solid and liquid phases were prolonged. The lag phase is affected by proximal vagotomy and is mainly determined by the distal stomach, which appears to be essential for normal emptying.

  11. 14 CFR 25.29 - Empty weight and corresponding center of gravity.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Empty weight and corresponding center of gravity. 25.29 Section 25.29 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... and corresponding center of gravity. (a) The empty weight and corresponding center of gravity must be...

  12. 14 CFR 29.29 - Empty weight and corresponding center of gravity.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Empty weight and corresponding center of gravity. 29.29 Section 29.29 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... weight and corresponding center of gravity. (a) The empty weight and corresponding center of gravity must...

  13. 14 CFR 27.29 - Empty weight and corresponding center of gravity.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Empty weight and corresponding center of gravity. 27.29 Section 27.29 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... and corresponding center of gravity. (a) The empty weight and corresponding center of gravity must be...

  14. Beating motion of a circular cylinder in vortex-induced vibrations

    Science.gov (United States)

    Shen, Linwei; Chan, Eng-Soon; Wei, Yan

    2018-04-01

    In this paper, beating phenomenon of a circular cylinder in vortex-induced vibration is studied by numerical simulations in a systematic manner. The cylinder mass coefficients of 2 and 10 are considered, and the Reynolds number is 150. Two distinctive frequencies, namely cylinder oscillation and vortex shedding frequencies, are obtained from the harmonic analysis of the cylinder displacement. The result is consistent with that observed in laboratory experiments. It is found that the cylinder oscillation frequency changes with the natural frequency of the cylinder while the reduced velocity is varied. The added-mass coefficient of the cylinder in beating motion is therefore estimated. Meanwhile, the vortex shedding frequency does not change dramatically in the beating situations. In fact, it is very close to 0.2. Accordingly, the lift force coefficient has two main components associated with these two frequencies. Besides, higher harmonics of the cylinder oscillation frequency appear in the spectrum of the lift coefficient. Moreover, the vortex shedding timing is studied in the beating motion by examining the instantaneous flow fields in the wake, and two scenarios of the vortex formation are observed.

  15. Parallel gastric emptying of nonhydrolyzable fat and water after a solid-liquid meal in humans

    International Nuclear Information System (INIS)

    Cortot, A.; Phillips, S.F.; Malagelada, J.R.

    1982-01-01

    Our aim was to examine the control of gastric emptying of the oil phase of a mixed solid and liquid meal. Previous studies had shown that liquid dietary fats normally leave the stomach at a slower rate than does water. We wished to determine whether the slower emptying of fats was due to the physical characteristics of food (lower density and greater viscosity than water), to retardation by duodenal feedback mechanisms, or whether both factors contributed. Thus, we quantified the emptying rates of water and sucrose polyester (a nonabsorbable analog of dietary fat) ingested by healthy volunteers as a mixed solid and liquid meal. Gastric emptying was quantified by an intubation-perfusion method incorporating an occlusive jejunal balloon to facilitate recovery. Four phase-specific, nonabsorbable markers were used. [14C[Sucrose octaoleate and polyethylene glycol were incorporated in the meal and traced the lipid and water phases, respectively; [3H]glycerol triether and phenolsulfonphthalein were used as duodenal recovery markers. Sucrose polyester (substituting for dietary fat) was emptied very rapidly, and at about the same rate as was water, in contrast to natural fat, which empties very slowly. Emptying of water was rapid and comparable to that observed after mixed meals containing natural fat. These results imply that gastric emptying of the oil phase is controlled by receptors sensitive to the hydrolytic products of fat digestion and that the slow emptying of dietary fat is not simply due to its lower density

  16. Inflation of polymer melts into elliptic and circular cylinders

    DEFF Research Database (Denmark)

    Rasmussen, Henrik Koblitz; Christensen, Jens Horslund; Gøttsche, Søren

    2000-01-01

    A thin sheet (membrane) of the polymeric material is clamped between a Teflon-coated thermostated plate and a thermostated aluminium cylinder. By applying thermostated air through the plate, the polymer membrane deforms into an elliptic or a circular cylinder. The position of the top of the infla......A thin sheet (membrane) of the polymeric material is clamped between a Teflon-coated thermostated plate and a thermostated aluminium cylinder. By applying thermostated air through the plate, the polymer membrane deforms into an elliptic or a circular cylinder. The position of the top...

  17. Electromagnetic forces on type-II superconducting rotating cylinders

    International Nuclear Information System (INIS)

    Saif, A.G.; Refai, T.F.; El-Sabagh, M.A.

    1995-01-01

    Analytical solutions of the electromagnetic fields are presented for a system composed of an infinitely long superconducting cylinder rotating about its axis and placed parallel to two infinitely long normal conducting wires. Both wires carry the same alternating current. From the obtained electromagnetic fields the electromagnetic power loss on the cylinder surface, electromagnetic forces due to induced currents, electromagnetic torque, and the work opposing the rotation of the cylinder are calculated. (orig.)

  18. Flow induced by a skewed vortex cylinder

    DEFF Research Database (Denmark)

    Branlard, Emmanuel Simon Pierre

    2017-01-01

    The velocity field induced by a skewed vortex cylinder of longitudinal and tangential vorticity is derived in this chapter by direct integration of the Biot– Savart law. The derivation steps are provided in details. The results of Castles and Durham for the skewed semi-infinite cylinder....... The content of this chapter is based on the publication of the author entitled "Cylindrical vortex wake model: skewed cylinder, application to yawed or tilted rotors" [1]. Results from this chapter are applied: in Chap. 21 to model a wind turbine (or rotor) in yaw, in Chap. 22 to derive a new yaw...

  19. Oscillatory Stokes Flow Past a Slip Cylinder

    Science.gov (United States)

    Palaniappan, D.

    2013-11-01

    Two-dimensional transient slow viscous flow past a circular cylinder with Navier slip boundary conditions is considered in the limit of low-Reynolds number. The oscillatory Stokes flow problem around a cylinder is solved using the stream function method leading to an analytic solution in terms of modified Bessel functions of the second kind. The corresponding steady-state behavior yields the familiar paradoxical result first detected by Stokes. It is noted that the two key parameters, viz., the frequency λ, and the slip coefficient ξ have a significant impact on the flow field in the vicinity of the cylinder contour. In the limit of very low frequency, the flow is dominated by a term containing a well-known biharmonic function found by Stokes that has a singular behavior at infinity. Local streamlines for small times show interesting flow patterns. Attached eddies due to flow separation - observed in the no-slip case - either get detached or pushed away from the cylinder surface as ξ is varied. Computed asymptotic results predict that the flow exhibits inviscid behavior far away from the cylinder in the frequency range 0 < λ << 1 . Although the frequency of oscillations is finite, our exact solutions reveal fairly rapid transitions in the flow domain. Research Enhancement grant, TAMUCC.

  20. Studies on gastric emptying time in patients with liver cirrhosis by radioisotope technique

    Energy Technology Data Exchange (ETDEWEB)

    Suyama, Hideaki

    1984-10-01

    In order to elucidate changes in gastric emptying in liver cirrhosis patients, gastric emptying half time (T1/2) was measured using /sup 99/Tc-DTPA. The study was performed by analyzing the gastroscintigram and the gastric emptying curve using the nuclear medicine data analyzer (shimazu Scinti Pack 1200). As a result, a distinctive delay in T1/2 was recognized in patients with liver cirrhosis, in comparison with normal subjects. In addition, the delay in T1/2 is more remarkable in cirrhotic patients with esophageal varices and/or gastric varices. Furthermore, cirrhotic patients with erosive gastritis and/or gastric ulcer showed a more distinctive delay than those without gastric lesions. In cases in which the T1/2 emptying time exceeds 80 minutes, incidence of gastric lesions was high (80%). From the above observation, the delay in gastric emptying is considered as one of the factors contributing to the high incidence of gastric lesions in liver cirrhosis patients.

  1. Ectopic jejunal pacemakers and gastric emptying after Roux gastrectomy: Effect of intestinal pacing

    International Nuclear Information System (INIS)

    Karlstrom, L.; Kelly, K.A.

    1989-01-01

    The aims of this study were to determine whether ectopic pacemakers are present after meals in the Roux limbs of dogs after vagotomy and Roux gastrectomy, whether these pacemakers slow gastric emptying of liquids or solids, and whether abolishing the pacemakers with electric pacing might speed any slow emptying that occurs. In six dogs that underwent vagotomy and Roux gastrectomy and in four dogs that underwent vagotomy and Billroth gastrectomy (controls), myoelectric activity of the Roux limb or duodenum was measured during gastric emptying of a 500 kcal mixed meal of 99mTc-labeled cooked egg and 111In-labeled milk. Roux dogs were tested with and without pacing of the Roux limb. Roux dogs showed ectopic pacemaker in the Roux limb that drove the pacesetter potentials of the limb in a reverse, or orad, direction during 57% of the postprandial recordings. Billroth dogs had no ectopic pacemakers (p less than 0.05). Liquids emptied more slowly in Roux dogs (half-life (t1/2) = 121 +/- 15 minutes) than in Billroth dogs (t1/2 = 43 +/- 9 minutes; p less than 0.05), but solids emptied similarly in both groups of dogs (t1/2 approximately 8 hours). Pacing the Roux limb abolished the ectopic pacemakers, restored the slow emptying of liquids to the more rapid rate found in the Billroth dogs (t1/2: paced Roux, 72 +/- 15 minutes; Billroth, 43 +/- 9 minutes; p greater than 0.05) and did not change emptying of solids. The conclusion was that ectopic pacemakers present in the Roux limb after vagotomy and Roux gastrectomy drove the limb in a reverse direction and slowed emptying of liquids after the operation. The defect was corrected by pacing the Roux limb in a forward direction

  2. Ectopic jejunal pacemakers and gastric emptying after Roux gastrectomy: Effect of intestinal pacing

    Energy Technology Data Exchange (ETDEWEB)

    Karlstrom, L.; Kelly, K.A. (Mayo Clinic, Rochester, MN (USA))

    1989-11-01

    The aims of this study were to determine whether ectopic pacemakers are present after meals in the Roux limbs of dogs after vagotomy and Roux gastrectomy, whether these pacemakers slow gastric emptying of liquids or solids, and whether abolishing the pacemakers with electric pacing might speed any slow emptying that occurs. In six dogs that underwent vagotomy and Roux gastrectomy and in four dogs that underwent vagotomy and Billroth gastrectomy (controls), myoelectric activity of the Roux limb or duodenum was measured during gastric emptying of a 500 kcal mixed meal of 99mTc-labeled cooked egg and 111In-labeled milk. Roux dogs were tested with and without pacing of the Roux limb. Roux dogs showed ectopic pacemaker in the Roux limb that drove the pacesetter potentials of the limb in a reverse, or orad, direction during 57% of the postprandial recordings. Billroth dogs had no ectopic pacemakers (p less than 0.05). Liquids emptied more slowly in Roux dogs (half-life (t1/2) = 121 +/- 15 minutes) than in Billroth dogs (t1/2 = 43 +/- 9 minutes; p less than 0.05), but solids emptied similarly in both groups of dogs (t1/2 approximately 8 hours). Pacing the Roux limb abolished the ectopic pacemakers, restored the slow emptying of liquids to the more rapid rate found in the Billroth dogs (t1/2: paced Roux, 72 +/- 15 minutes; Billroth, 43 +/- 9 minutes; p greater than 0.05) and did not change emptying of solids. The conclusion was that ectopic pacemakers present in the Roux limb after vagotomy and Roux gastrectomy drove the limb in a reverse direction and slowed emptying of liquids after the operation. The defect was corrected by pacing the Roux limb in a forward direction.

  3. Adult Health: Worried About Empty Nest Syndrome?

    Science.gov (United States)

    ... clinical diagnosis. Instead, empty nest syndrome is a phenomenon in which parents experience feelings of sadness and loss when the last child leaves home. Although you might actively encourage your ...

  4. Enigmatic electrons, photons, and ''empty'' waves

    International Nuclear Information System (INIS)

    MacGregor, M.H.

    1995-01-01

    A spectroscopic analysis is made of electrons and photons from the standpoint of physical realism. In this conceptual framework, moving particles are portrayed as localized entities which are surrounded by ''empty'' waves. A spectroscopic model for the electron Stands as a guide for a somewhat similar, but in essential respects radically different, model for the photon. This leads in turn to a model for the ''zeron''. the quantum of the empty wave. The properties of these quanta mandate new basis states, and hence an extension of our customary framework for dealing with them. The zeron wave field of a photon differs in one important respect from the standard formalism for an electromagnetic wave. The vacuum state emerges as more than just a passive bystander. Its polarization properties provide wave stabilization, particle probability distributions, and orbit quantization. Questions with regard to special relativity are discussed

  5. Vortex structure behind highly heated two cylinders in parallel arrangements

    International Nuclear Information System (INIS)

    Kurita, Eiichirou; Yahagi, Yuji

    2008-01-01

    Vortex structures behind twin, highly heated cylinders in parallel arrangements have been investigated experimentally. The experiments were conducted under the following conditions: cylinder diameter, D=4 mm; mean flow velocity, U ∞ =1.0 m/s; Reynolds number, Re=250; cylinder clearance, S/D=0.5 - 1.4; and cylinder heat flux, q=0 - 72.6 kW/m 2 . For S/D > 1.2, the Karman vortex street is formed alternately behind each cylinder divided on the slit flow. The slit flow velocity increases with a decrease in S/D and decreases with increasing heat flux. For S/D 2 ). As a result, the increased local kinematic viscosity and S/D play a key role for the vortex structure and formation behind arrangements of two parallel cylinders. (author)

  6. Controlling chaos in a fluid flow past a movable cylinder

    International Nuclear Information System (INIS)

    Vallejo, Juan C.; Marino, Ines P.; Sanjuan, Miguel A.F.; Kurths, Juergen

    2003-01-01

    The model of a two-dimensional fluid flow past a cylinder is a relatively simple problem with a strong impact in many applied fields, such as aerodynamics or chemical sciences, although most of the involved physical mechanisms are not yet well known. This paper analyzes the fluid flow past a cylinder in a laminar regime with Reynolds number, Re, around 200, where two vortices appear behind the cylinder, by using an appropriate time-dependent stream function and applying non-linear dynamics techniques. The goal of the paper is to analyze under which circumstances the chaoticity in the wake of the cylinder might be modified, or even suppressed. And this has been achieved with the help of some indicators of the complexity of the trajectories for the cases of a rotating cylinder and an oscillating cylinder

  7. 76 FR 55736 - Safety Advisory: Unauthorized Marking of Compressed Gas Cylinders

    Science.gov (United States)

    2011-09-08

    ... certain of high- and low-pressure compressed gas cylinders, primarily fire extinguishers, by Atlas Fire...- pressure cylinders serviced by Atlas Fire Protection were marked and represented as requalified (visually... damage, serious personal injury, or death could result from the rupture of a cylinder. Cylinders not...

  8. The effects of increasing liquid calories on gastric emptying in normal subjects

    International Nuclear Information System (INIS)

    Collins, P.; Cook, D.; Horowitz, M.; Shearman, D.; Harding, P.

    1982-01-01

    Radionuclide methods are the simplest and potentially the most accurate techniques for the measurement of gastric emptying, but there are methodological problems which may limit the sentivity and specificity of these tests. A significant source of error is photon attenuation, due to the changing depth of radionuclides in the stomach during the study. This error can be eliminated by adding counts obtained in both anterior and posterior views or by applying attenuation correction factors to the data. Radionuclides were used to study the effect of increasing the calorie content of the liquid component of a mixed solid-liquid meal on gastric emptying in normal subjects, using a single detector system, and assessed the reproductibility of the technique. The solid meal comprised 1-1.5 mCi ''in vivo'' sup(99m)Tc-labelled chicken liver which was added to 100 g of ground beef and the resultant ''hamburger'' grilled. The liquids studied were 0.5 mCi sup(113m)In-diethyltriaminepentaacetic acid (DTPA) added to 100 ml of either water, 10% dextrose or 25% dextrose. In this study the progressive increase in caloric content of the liquid meal from 0 to 0.4 to 1 kcal/ml resulted in a corresponding delay in both solid and liquid emptying. For liquids a generalised slowing of the entire emptying curve was evident, while the delay in solid emptying reflected a lengthening of the lag period, with no alteraction in the rate of linear emptying

  9. Use of technegas as a radiopharmaceutical for the measurement of gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Kwiatek, M.A. [School of Medical Radiation, University of South Australia, Adelaide (Australia); Jones, K.L. [School of Medical Radiation, University of South Australia, Adelaide (Australia)]|[Department of Medicine, Royal Adelaide Hospital, The University of Adelaide, Adelaide (Australia); Burch, W.M. [John Curtin School of Medical Research, Australian National University, Australian Capital Territory (Australia); Horowitz, M. [Department of Medicine, Royal Adelaide Hospital, The University of Adelaide, Adelaide (Australia); Bartholomeusz, F.D.L. [Department of Nuclear Medicine, Royal Adelaide Hospital, Adelaide (Australia)

    1999-08-01

    Many radiopharmaceuticals and test meals that are used to measure gastric emptying are less than optimal. A vegetable-based solid meal, such as rice, labelled with a radiopharmaceutical that also has the capacity to measure gastric emptying of liquids, is likely to be ideal. The role of Technegas as a radioisotopic marker to measure gastric emptying of rice and liquids was evaluated. Technegas-labelled rice was incubated in 0.9% saline, 1 M HCl and simulated gastric fluid (3.2 g/l pepsinogen, pH 2-3) to assess stability of the label. In eight healthy volunteers gastric emptying of two meals - 200 g rice (370 kcal) and 75 g dextrose dissolved in 300 ml water (300 kcal), both labelled with 20 MBq of Technegas - was measured scintigraphically. Over 4 h, the average label stability was 93.7%{+-}0.5% in 0.9% saline, 91.0%{+-}0.4% in 1 M HCl and 93.6%{+-}0.7% in simulated gastric juice. The lag phase was longer for rice than dextrose (25{+-}7 min vs 4{+-}2 min; P<0.05), but there was no difference in the post-lag emptying rate (2.1{+-}0.3 kcal/min vs 1.7{+-}0.2 kcal/min; P=0.2) between the two meals. We conclude that Technegas is a suitable radiopharmaceutical for measurement of gastric emptying of rice and nutrient-containing liquids. (orig.) With 2 figs., 16 refs.

  10. The Passive Neutron Enrichment Meter for Uranium Cylinder Assay

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Karen A.; Menlove, Howard O.; Swinhoe, Martyn T.; Marlow, Johanna B. [Safeguards Science and Technology Group (N-1), Los Alamos National Laboratory, Los Alamos (United States)

    2011-12-15

    As fuel cycle technology becomes more prevalent around the world, international safeguards have become increasingly important in verifying that nuclear materials have not been diverted. Uranium enrichment technology is a critical pathway to nuclear weapons development, making safeguards of enrichment facilities especially important. Independently-verifiable material accountancy is a fundamental measure in detecting diversion of nuclear materials. This paper is about a new instrument for uranium cylinder assay for enrichment plant safeguards called the Passive Neutron Enrichment Meter (PNEM). The measurement objective is to simultaneously verify uranium mass and enrichment in Uf6 cylinders. It can be used with feed, product, and tails cylinders. Here, we consider the enrichment range up to 5% {sup 235}U. The concept is to use the Doubles-to-Singles count rate to give a measure of the {sup 235}U enrichment and the Singles count rate to provide a measure of the total uranium mass. The cadmium ratio is an additional signature for the enrichment that is especially useful for feed and tails cylinders. PNEM is a {sup 3}He-based system that consists of two portable detector pods. Uranium enrichment in UF{sub 6} cylinders is typically determined using a gamma-ray-based method that only samples a tiny volume of the cylinder's content and requires knowledge of the cylinder wall thickness. The PNEM approach has several advantages over gamma-ray-based methods including a deeper penetration depth into the cylinder, meaning it can be used with heterogeneous isotopic mixtures of UF{sub 6}. In this paper, we describe a Monte Carlo modelling study where we have examined the sensitivity of the system to systematic uncertainties such as the distribution of UF{sub 6} within the cylinder. We also compare characterization measurements of the PNEM prototype to the expected measurements calculated with Monte Carlo simulations.

  11. Applied potential tomography. A new noninvasive technique for measuring gastric emptying

    International Nuclear Information System (INIS)

    Avill, R.; Mangnall, Y.F.; Bird, N.C.; Brown, B.H.; Barber, D.C.; Seagar, A.D.; Johnson, A.G.; Read, N.W.

    1987-01-01

    Applied potential tomography is a new, noninvasive technique that yields sequential images of the resistivity of gastric contents after subjects have ingested a liquid or semisolid meal. This study validates the technique as a means of measuring gastric emptying. Experiments in vitro showed an excellent correlation between measurements of resistivity and either the square of the radius of a glass rod or the volume of water in a spherical balloon when both were placed in an oval tank containing saline. Altering the lateral position of the rod in the tank did not alter the values obtained. Images of abdominal resistivity were also directly correlated with the volume of air in a gastric balloon. Profiles of gastric emptying of liquid meals obtained using applied potential tomography were very similar to those obtained using scintigraphy or dye dilution techniques, provided that acid secretion was inhibited by cimetidine. Profiles of emptying of a mashed potato meal using applied potential tomography were also very similar to those obtained by scintigraphy. Measurements of the emptying of a liquid meal from the stomach were reproducible if acid secretion was inhibited by cimetidine. Thus, applied potential tomography is an accurate and reproducible method of measuring gastric emptying of liquids and particulate food. It is inexpensive, well tolerated, easy to use, and ideally suited for multiple studies in patients, even those who are pregnant

  12. Applied potential tomography. A new noninvasive technique for measuring gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Avill, R.; Mangnall, Y.F.; Bird, N.C.; Brown, B.H.; Barber, D.C.; Seagar, A.D.; Johnson, A.G.; Read, N.W.

    1987-04-01

    Applied potential tomography is a new, noninvasive technique that yields sequential images of the resistivity of gastric contents after subjects have ingested a liquid or semisolid meal. This study validates the technique as a means of measuring gastric emptying. Experiments in vitro showed an excellent correlation between measurements of resistivity and either the square of the radius of a glass rod or the volume of water in a spherical balloon when both were placed in an oval tank containing saline. Altering the lateral position of the rod in the tank did not alter the values obtained. Images of abdominal resistivity were also directly correlated with the volume of air in a gastric balloon. Profiles of gastric emptying of liquid meals obtained using applied potential tomography were very similar to those obtained using scintigraphy or dye dilution techniques, provided that acid secretion was inhibited by cimetidine. Profiles of emptying of a mashed potato meal using applied potential tomography were also very similar to those obtained by scintigraphy. Measurements of the emptying of a liquid meal from the stomach were reproducible if acid secretion was inhibited by cimetidine. Thus, applied potential tomography is an accurate and reproducible method of measuring gastric emptying of liquids and particulate food. It is inexpensive, well tolerated, easy to use, and ideally suited for multiple studies in patients, even those who are pregnant.

  13. Gastric emptying and timing of insulin injection in insulin-treated diabetics Using99m Te-sulfur colloid

    International Nuclear Information System (INIS)

    Sheta, M.; El-Borrolossy, H.; El-Tawil, A.

    1997-01-01

    Gastric emptying of 99m Tc labelled liquid and solid meals were studied in 112 long-standing insulin insulin treated diabetics to evaluate the relationship of gastroparesis to patients age, sex, gastrointestinal symptoms, diabetic neuropathic complication and glycemic control, and to evaluate the influence of gastric emptying and timing of insulin injection as modifying factors for blood glucose control aiming at objective optimization of timing of insulin injection for every individual patient using the proposed equation: time of insulin injection=onset of insulin action -solid lag time. Patients were classified into three group: A) no neuropathy; B) peripheral neuropathy; and C) peripheral and autonomic neuropathy and compared to healthy volunteers as controls. Diabetics showed statistically significant prolonged gastric lag time and T1/2 for both liquid and solid meals compared to those of controls

  14. Separation of empty microcapsules after microencapsulation of porcine neonatal islets.

    Science.gov (United States)

    Shin, Soojeong; Yoo, Young Je

    2013-12-01

    Pancreatic islet transplantation is used to treat diabetes mellitus that has minimal complications and avoids hypoglycemic shock. Conformal microencapsulation of pancreatic islets improves their function by blocking immunogenic molecules while protecting fragile islets. However, production of empty alginate capsules during microencapsulation causes enlargement of the transplantation volume of the encapsulated islets and interferes with efficient transfer of nutrients and insulin. In this study, empty alginate capsules were separated after microencapsulation of neonatal porcine islet-like cell clusters (NPCC) using density-gradient centrifugation. Densities of NPCC and alginate capsules were determined using Percoll. Encapsulation products following alginate removal were 97 % of products, with less than 10 % of the capsules remaining empty. The viability of this process compared with manually-selected encapsulated islets indicates the separation process does not harm islets.

  15. Proximity functions for general right cylinders

    International Nuclear Information System (INIS)

    Kellerer, A.M.

    1981-01-01

    Distributions of distances between pairs of points within geometrical objects, or the closely related proximity functions and geometric reduction factors, have applications to dosimetric and microdosimetric calculations. For convex bodies these functions are linked to the chord-length distributions that result from random intersections by straight lines. A synopsis of the most important relations is given. The proximity functions and related functions are derived for right cylinders with arbitrary cross sections. The solution utilizes the fact that the squares of the distances between two random points are sums of independently distributed squares of distances parallel and perpendicular to the axis of the cylinder. Analogous formulas are derived for the proximity functions or geometric reduction factors for a cylinder relative to a point. This requires only a minor modification of the solution

  16. Background does not significantly affect power-exponential fitting of gastric emptying curves

    International Nuclear Information System (INIS)

    Jonderko, K.

    1987-01-01

    Using a procedure enabling the assessment of background radiation, research was done to elucidate the course of changes in background activity during gastric emptying measurements. Attention was focused on the changes in the shape of power-exponential fitted gastric emptying curves after correction for background was performed. The observed pattern of background counts allowed to explain the shifts of the parameters characterizing power-exponential curves connected with background correction. It was concluded that background had a negligible effect on the power-exponential fitting of gastric emptying curves. (author)

  17. ROBUST CYLINDER FITTING IN THREE-DIMENSIONAL POINT CLOUD DATA

    Directory of Open Access Journals (Sweden)

    A. Nurunnabi

    2017-05-01

    Full Text Available This paper investigates the problems of cylinder fitting in laser scanning three-dimensional Point Cloud Data (PCD. Most existing methods require full cylinder data, do not study the presence of outliers, and are not statistically robust. But especially mobile laser scanning often has incomplete data, as street poles for example are only scanned from the road. Moreover, existence of outliers is common. Outliers may occur as random or systematic errors, and may be scattered and/or clustered. In this paper, we present a statistically robust cylinder fitting algorithm for PCD that combines Robust Principal Component Analysis (RPCA with robust regression. Robust principal components as obtained by RPCA allow estimating cylinder directions more accurately, and an existing efficient circle fitting algorithm following robust regression principles, properly fit cylinder. We demonstrate the performance of the proposed method on artificial and real PCD. Results show that the proposed method provides more accurate and robust results: (i in the presence of noise and high percentage of outliers, (ii for incomplete as well as complete data, (iii for small and large number of points, and (iv for different sizes of radius. On 1000 simulated quarter cylinders of 1m radius with 10% outliers a PCA based method fit cylinders with a radius of on average 3.63 meter (m; the proposed method on the other hand fit cylinders of on average 1.02 m radius. The algorithm has potential in applications such as fitting cylindrical (e.g., light and traffic poles, diameter at breast height estimation for trees, and building and bridge information modelling.

  18. 75 FR 30292 - Airworthiness Directives; AVOX Systems and B/E Aerospace Oxygen Cylinders as Installed on Various...

    Science.gov (United States)

    2010-06-01

    ... by the reported rupture of a high-pressure gaseous oxygen cylinder, which had insufficient strength... supply for the flightcrew, and injury to cabin occupants or other support personnel. DATES: This AD... incorporation by reference of certain publications listed in this AD. ADDRESSES: For service information...

  19. The Silhouette Zoetrope: A New Blend of Motion, Mirroring, Depth, and Size Illusions.

    Science.gov (United States)

    Veras, Christine; Pham, Quang-Cuong; Maus, Gerrit W

    2017-01-01

    Here, we report a novel combination of visual illusions in one stimulus device, a contemporary innovation of the traditional zoetrope, called Silhouette Zoetrope. In this new device, an animation of moving silhouettes is created by sequential cutouts placed outside a rotating empty cylinder, with slits illuminating the cutouts successively from the back. This "inside-out" zoetrope incurs the following visual effects: the resulting animated figures are perceived (a) horizontally flipped, (b) inside the cylinder, and (c) appear to be of different size than the actual cutout object. Here, we explore the unique combination of illusions in this new device. We demonstrate how the geometry of the device leads to a retinal image consistent with a mirrored and distorted image and binocular disparities consistent with the perception of an object inside the cylinder.

  20. An experiments and characteristics analysis of the sealless cylinder

    International Nuclear Information System (INIS)

    Kim, Young Cheol; Kim, Dong Soo; Bae, Sang Kyu; Kim, Sung Jong

    2004-01-01

    This paper shows a performance analysis for conical type sealless cylinders and rod bearings. The pistons without seal have partly cylindrical and conical shapes. 2 dimensional Reynolds equation and FD(Finite Differential) numerical techniques are utilized for the performance analysis. The relationship among self-centering forces and leakage flows are investigated. Also, optimal design values for a sealless cylinder are presented. A prototype of sealless cylinder which had rod bearing with four pockets, five pockets, and six pockets was manufactured respectively. Leakage flow test is conducted to evaluate performance of piston and rod bearing in sealless cylinder

  1. Magnetic susceptibility in the edged topological disordered nanoscopic cylinder

    International Nuclear Information System (INIS)

    Faizabadi, Edris; Omidi, Mahboubeh

    2011-01-01

    The effects of edged topological disorder on magnetic susceptibility are investigated in a nanoscopic cylinder threaded by a magnetic flux. Persistent current versus even or odd number of electrons shows different signs in ordered and disordered cylinders and also in short or long ones. In addition, temperature-averaged susceptibility has only diamagnetic signs in strong regimes and it is associated with paramagnetic signs in ordered and weak disordered ones. Besides, in an edged topological disordered cylinder, the temperature-averaged susceptibility decreases by raising the temperature somewhat and then increasing initiates and finally at high temperature tends to zero as the ordered one. - Research highlights: → Magnetic susceptibility in one-dimensional topological disordered quantum ring. → Edged topological disorder effect on magnetic susceptibility in nanoscopic cylinder. → Edged topological disorder effect on temperature-averaged susceptibility in cylinder.

  2. A simple scintigraphic method for continuous monitoring of gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Lipp, R.W.; Hammer, H.F.; Schnedl, W.; Dobnig, H.; Passath, A.; Leb, G.; Krejs, G.J. (Graz Univ. (Austria). Div. of Nuclear Medicine and Endocrinology)

    1993-03-01

    A new and simple scintigraphic method for the measurement of gastric emptying was developed and validated. The test meal consists of 200 g potato mash mixed with 0.5 g Dowex 2X8 particles (mesh 20-50) labelled with 37 MBq (1 mCi) technetium-99m. After ingestion of the meal, sequential dynamic 15-s anteroposterior exposures in the supine position are obtained for 90 min. A second recording sequence of 20 min is added after a 30-min interval. The results can be displayed as immediate cine-replay, as time-activity diagrams and/or as acitivty retention values. Complicated mathematical fittings are not necessary. The method lends itself equally to the testing of in- and outpatients. (orig.).

  3. Dynamical instability of a charged gaseous cylinder

    Science.gov (United States)

    Sharif, M.; Mumtaz, Saadia

    2017-10-01

    In this paper, we discuss dynamical instability of a charged dissipative cylinder under radial oscillations. For this purpose, we follow the Eulerian and Lagrangian approaches to evaluate linearized perturbed equation of motion. We formulate perturbed pressure in terms of adiabatic index by applying the conservation of baryon numbers. A variational principle is established to determine characteristic frequencies of oscillation which define stability criteria for a gaseous cylinder. We compute the ranges of radii as well as adiabatic index for both charged and uncharged cases in Newtonian and post-Newtonian limits. We conclude that dynamical instability occurs in the presence of charge if the gaseous cylinder contracts to the radius R*.

  4. Prediction model of velocity field around circular cylinder over various Reynolds numbers by fusion convolutional neural networks based on pressure on the cylinder

    Science.gov (United States)

    Jin, Xiaowei; Cheng, Peng; Chen, Wen-Li; Li, Hui

    2018-04-01

    A data-driven model is proposed for the prediction of the velocity field around a cylinder by fusion convolutional neural networks (CNNs) using measurements of the pressure field on the cylinder. The model is based on the close relationship between the Reynolds stresses in the wake, the wake formation length, and the base pressure. Numerical simulations of flow around a cylinder at various Reynolds numbers are carried out to establish a dataset capturing the effect of the Reynolds number on various flow properties. The time series of pressure fluctuations on the cylinder is converted into a grid-like spatial-temporal topology to be handled as the input of a CNN. A CNN architecture composed of a fusion of paths with and without a pooling layer is designed. This architecture can capture both accurate spatial-temporal information and the features that are invariant of small translations in the temporal dimension of pressure fluctuations on the cylinder. The CNN is trained using the computational fluid dynamics (CFD) dataset to establish the mapping relationship between the pressure fluctuations on the cylinder and the velocity field around the cylinder. Adam (adaptive moment estimation), an efficient method for processing large-scale and high-dimensional machine learning problems, is employed to implement the optimization algorithm. The trained model is then tested over various Reynolds numbers. The predictions of this model are found to agree well with the CFD results, and the data-driven model successfully learns the underlying flow regimes, i.e., the relationship between wake structure and pressure experienced on the surface of a cylinder is well established.

  5. The effects of trimebutine maleate on gastric emptying in patients with non-ulcer dyspepsia

    Energy Technology Data Exchange (ETDEWEB)

    Aktas, A. [Baskent Univ., Ankara (Turkey); Caner, B.; Ozturk, F.; Bayhan, H.; Narin, Y.; Mentes, T.

    1999-08-01

    The study was designed to investigate the effect of trimebutine maleate, a drug used in both hyperkinetic and hypokinetic motility disorders, on gastric emptying in patients with non-ulcer dyspepsia having prolonged gastric emptying rates and to compare the parameters used for the determination of the lag period observed during the emptying of solid foods from the stomach. Gastric emptying was measured by the radionuclide technique. Twenty normal volunteers and 43 patients with non-ulcer dyspepsia participated in the study. Radionuclide imaging was performed by using a solid meal labeled with {sup 99m}Tc-tin colloid. Of the patients with non-ulcer dyspepsia, 20 had prolonged gastric emptying. They were given three weeks of oral treatment with trimebutine maleate and had their radionuclide gastric emptying study repeated. Treatment with trimebutine maleate resulted in reduction in duration of the lag period and less retention of food at 100 minutes (p<0.0005). After treatment with trimebutine maleate, no significant difference has been observed in the mean symptom score of patients with prolonged gastric emptying. Among the parameters used for the determination of the lag period, lag period determined by a mathematical equation (TLAG) has been found to be longer than the lag period determined by visual inspection of the images (VLAG) and there was correlation between the two parameters when the lag time was short. (author)

  6. checkCIF/PLATON report Datablock: b3_0m

    Indian Academy of Sciences (India)

    As a result the full set of tests cannot be run. No syntax errors found. CIF dictionary Interpreting this report. Datablock: b3_0m. Bond precision: C-C = 0.0207 A. Wavelength=0.71073. Cell: a=11.0782(11) b=6.6521(7) c=12.1645(12) alpha=90 beta=101.798(4) gamma=90. Temperature: 296 K. Calculated. Reported. Volume.

  7. Intermodal Transport and Repositioning of Empty Containers in Central and Eastern Europe Hinterland

    DEFF Research Database (Denmark)

    Kolar, Petr; Schramm, Hans-Joachim; Prockl, Günter

    2018-01-01

    The objective of this article is to provide a review of literature dealing with empty container repositioning. This review is interlinked with a qualitative data analysis based on semi-structured interviews with representatives of ocean carriers, which are key actors determining empty container....... By addressing the research questions and conducting the analysis, the authors determine whether empty container repositioning is a problem only concerning equipment allocation by an ocean carrier or requires a collaborative resolution involving various parties engaged in container movements in landlocked...... hinterlands. This article confirms that most existing literature dealing with empty container repositioning ignores the actual dynamics of landlocked hinterlands as well as business practitioners' perspective. The authors' analysis of the empirical research complements and challenges the reviewed research...

  8. Technegas - A new radiopharmaceutical for the measurement of gastric emptying in normal subjects

    International Nuclear Information System (INIS)

    Kwiatek, M.A.; Jones, K.L.; Horowitz, M.; Bartholomeusz, F.D.L.

    1998-01-01

    Full text: Scintigraphy is now used widely to measure gastric emptying in humans. Both solid and liquid emptying should ideally be measured - most techniques employ test meals of minced beef and eggs. These meals are not always suitable for patients, especially those observing strict dietary regimens or vegetarians, in whom a vegetable-based meal such as rice is likely to be more acceptable. A previous study attempted to label rice with pertechnetate, but label stability was inadequate. The aim of this study was to determine whether Technegas could be used as a radioisotopic marker to assess gastric emptying of rice and liquids. The stability of Technegas rice was evaluated for three brands of rice by incubation in 0.9% saline, 1M HCI and simulated gastric fluid (3.2g/l pepsinogen, pH 2-4). The labelling stability of each type of rice after four hours was greater than 80%. Gastric emptying of 200g (370kcal) rice and 300ml (300kcal) dextrose drink, both labelled with approximately 20MBq of Technegas, was measured in eight normal subjects (6M, 2F) on two separate days. Venous blood samples were obtained for three hours after ingestion of the meal to quantify intestinal absorption of the radiolabel. Gastric emptying of rice was characterised by a lag phase followed by a linear emptying phase, while emptying of dextrose approximated a linear pattern after a short lag phase. The lag phase was longer for rice than dextrose (25±7min vs 4±2min; P<0.05), but there was no difference in the post lag emptying rate (2.1±0.3kca/min vs 1.7±0.2kcal/min; P=0.2), between the two meals. Intestinal absorption of the radiolabel increased over time, with a plateau after two hours; the total amount absorbed (5.3±13% rice and 6.7±1.8% dextrose) was small. These observations indicate that Technegas labelled rice and dextrose are suitable test meals for measurement of gastric emptying of solids and nutrient containing liquids

  9. Mechanical Integrity of Copper Canister Lid and Cylinder. Sensitivity study

    International Nuclear Information System (INIS)

    Karlsson, Marianne

    2002-08-01

    This report is part of a study of the mechanical integrity of canisters used for disposal of nuclear fuel waste. The overall objective is to determine and ensure the static and long-term strength of the copper canister lid and cylinder casing. The canisters used for disposal nuclear fuel waste of type BWR consists of an inner part (insert) of ductile cast iron and an outer part of copper. The copper canister is to provide a sealed barrier between the contents of the canister and the surroundings. The study in this report complements the finite element analyses performed in an earlier study. The analyses aim to evaluate the sensitivity of the canister to tolerances regarding the gap between the copper cylinder and the cast iron insert. Since great uncertainties regarding the material's long term creep properties prevail, analyses are also performed to evaluate the effect of different creep data on the resulting strain and stress state. The report analyses the mechanical response of the lid and flange of the copper canister when subjected to loads caused by pressure from swelling bentonite and from groundwater at a depth of 500 meter. The loads acting on the canister are somewhat uncertain and the cases investigated in this report are possible cases. Load cases analysed are: Pressure 15 MPa uniformly distributed on lid and 5 MPa uniformly distributed on cylinder; Pressure 5 MPa uniformly distributed on lid and 15 MPa uniformly distributed on cylinder; Pressure 20 MPa uniformly distributed on lid and cylinder; and Side pressures 10 MPa and 20 MPa uniformly distributed on part of the cylinder. Creep analyses are performed for two of the load cases. For all considered designs high principal stresses appear on the outside of the copper cylinder in the region from the weld down to the level of the lid lower edge. Altering the gap between lid and cylinder and/or between cylinder and insert only marginally affects the resulting stress state. Fitting the lid in the cylinder

  10. Evaluation of Concrete Cylinder Tests Using Finite Elements

    DEFF Research Database (Denmark)

    Saabye Ottosen, Niels

    1984-01-01

    Nonlinear axisymmetric finite element analyses are performed on the uniaxial compressive test of concrete cylinders. The models include thick steel loading plates, and cylinders with height‐to‐diameter ratios (h/d) ranging from 1‐3 are treated. A simple constitutive model of the concrete is emplo......Nonlinear axisymmetric finite element analyses are performed on the uniaxial compressive test of concrete cylinders. The models include thick steel loading plates, and cylinders with height‐to‐diameter ratios (h/d) ranging from 1‐3 are treated. A simple constitutive model of the concrete...... uniaxial strength the use of geometrically matched loading plates seems to be advantageous. Finally, it is observed that for variations of the element size within limits otherwise required to obtain a realistic analysis, the results are insensitive to the element size....

  11. Evaluation of gastric emptying by means of scintigraphy using different test meals

    Energy Technology Data Exchange (ETDEWEB)

    Montoya, V.; Quintao, M.F.; Marino, V.S.P.; Coelho, L.G.V.; Mota, Luciene G.; Mourao, Arnaldo Prata [Universidade Federal de Minas Ferais (UFMG), Belo Horizonte, MG (Brazil); Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET-MG), Belo Horizonte (Brazil)

    2017-11-01

    Gastroparesis is a disorder characterized by symptoms and evidence of delayed gastric emptying (GE) in the absence of mechanical obstruction. Scintigraphy has been considered a 'gold standard' for measuring Gastric Emptying Time (GET) and retention percentage of radio-labeled food, after four hours of ingestion. To obtain the images, it is recommended, worldwide, the use of the Tougas diet (227 kcal) as a standard meal. The objective of this study was to compare the GET and the percentage of retention in the time of 4h, obtained by scintigraphy using the Tougas diet and the proposed diet (319 kcal). We selected 30 patients, both genders, aged between 23 and 76 years, presenting clinical symptoms suggestive of gastroparesis. These parameters were measured for the same patient, but on different days. The results showed that the fat content of the diet used to obtain EG scintigraphy of solid foods did not influence retention percentage results after 4 hours of ingestion of the radiolabeled food. However, the time of two hours is an important parameter to be observed in the result of this examination. In addition, the data suggest that the proposed diet may be more efficient for the classification of the severity of EG delay in patients with clinical signs suggestive of gastroparesis. (author)

  12. Evaluation of gastric emptying by means of scintigraphy using different test meals

    International Nuclear Information System (INIS)

    Montoya, V.; Quintao, M.F.; Marino, V.S.P.; Coelho, L.G.V.; Mota, Luciene G.; Mourao, Arnaldo Prata

    2017-01-01

    Gastroparesis is a disorder characterized by symptoms and evidence of delayed gastric emptying (GE) in the absence of mechanical obstruction. Scintigraphy has been considered a 'gold standard' for measuring Gastric Emptying Time (GET) and retention percentage of radio-labeled food, after four hours of ingestion. To obtain the images, it is recommended, worldwide, the use of the Tougas diet (227 kcal) as a standard meal. The objective of this study was to compare the GET and the percentage of retention in the time of 4h, obtained by scintigraphy using the Tougas diet and the proposed diet (319 kcal). We selected 30 patients, both genders, aged between 23 and 76 years, presenting clinical symptoms suggestive of gastroparesis. These parameters were measured for the same patient, but on different days. The results showed that the fat content of the diet used to obtain EG scintigraphy of solid foods did not influence retention percentage results after 4 hours of ingestion of the radiolabeled food. However, the time of two hours is an important parameter to be observed in the result of this examination. In addition, the data suggest that the proposed diet may be more efficient for the classification of the severity of EG delay in patients with clinical signs suggestive of gastroparesis. (author)

  13. Reverse Effect of Opuntia ficus-indica L. Juice and Seeds Aqueous Extract on Gastric Emptying and Small-Bowel Motility in Rat.

    Science.gov (United States)

    Rtibi, Kaïs; Selmi, Slimen; Saidani, Khouloud; Grami, Dhekra; Amri, Mohamed; Sebai, Hichem; Marzouki, Lamjed

    2018-01-01

    This study was conducted to compare the effects of juice and seeds on gastric emptying, small-bowel motility and intestinal ion transport. Separate groups of rats were randomized to receive NaCl, increasing doses of juice (5, 10, and 20 mL/kg, b.w.) or seeds aqueous extract (100, 200, and 400 mg/kg, b.w.). Simultaneously, two other groups were received, the reference drugs; clonidine (1 mg/kg) and yohimbine (2 mg/kg). The charcoal meal was used as a suspension for gastrointestinal motility test. The purgative action of juice was confirmed using the loperamide (5 mg/kg, p.o.) induced constipation. To evaluate the antisecretory effect, we were used as a hypersecretion agent, the castor oil at the dose of 5 mL/kg. Compared to the control and standard groups, we were showed that the prickly pear has an opposite effect on small-bowel motility and gastric emptying. Indeed, the juice at various doses has a laxative effect of gastrointestinal transit in healthy and constipated-rats. However, the aqueous extract of the seeds leads to a reduction of motility in normal rats which gives it a remarkable antidiarrhoeal activity, a notable intestinal fluid accumulation decline and electrolyte concentrations reestablishment. Moreover, orally juice administered at different doses accelerated the stomach emptying time in contrast to the seeds aqueous extract. More importantly, a significant variation in the phytochemical constituents levels between juice and seeds was found. These findings confirm the reverse therapeutic effects of this fruit in the treatment of digestive disturbances such as difficulty stool evacuation and massive intestinal secretion, likewise, the gastric emptying process perturbation. © 2017 Institute of Food Technologists®.

  14. Lack of modulation of gastric emptying by dietary nitrate in healthy volunteers.

    Science.gov (United States)

    Terai, Shiho; Iijima, Katsunori; Asanuma, Kiyotaka; Ara, Nobuyuki; Uno, Kaname; Abe, Yasuhiko; Koike, Tomoyuki; Imatani, Akira; Ohara, Shuichi; Shimosegawa, Tooru

    2009-05-01

    Nitric oxide produced endogenously in vagal neurons modulates gastrointestinal motor activity as an important non-adrenergic and non-cholinergic neurotransmitter. Other than through endogenous biosynthesis, a high concentration of nitric oxide also occurs by chemical reactions within the stomach in the presence of gastric acid through the entero-salivary re-circulation of dietary nitrate. Although dietary nitrate can be a potential source of nitric oxide in the human stomach, there has been no report on the effect of dietary nitrate on gastric motor function. The aim of this study is to investigate the effect of dietary nitrate on gastric emptying, one of the major parameters for the gastric motor function. Fifteen healthy volunteers underwent a placebo-controlled (310 mg sodium nitrate or placebo), double-blind, crossover trial. Since a sufficient amount of gastric acid is essential for dietary nitrate-derived nitric oxide generation in the stomach, the same protocol was repeated after 1-week treatment with a proton pump inhibitor, rabeprazole. Gastric emptying was evaluated by (13)C-octanoate breath test. The sodium nitrate ingestion did not affect gastric emptying either prior to or during rabeprazole treatment, although rabeprazole treatment itself significantly delayed gastric emptying, being independent of the dietary nitrate load. Confirmation of the delayed gastric emptying with rabeprazole indicates the sensitivity of the breath test employed in the present study. In conclusion, despite the potential nitrogen source of exogenous nitric oxide, the ingestion of 310 mg sodium nitrate, which is equivalent to the average daily intake of Japanese adults, does not affect gastric emptying in healthy volunteers.

  15. Technetium-99m carboxymethylcellulose: A newly developed fibre marker for gastric emptying studies

    International Nuclear Information System (INIS)

    Schade, J.H.; Hoving, J.; Brouweres, J.R.B.J.; Riedstra-van Gent, H.G.; Zijlstra, J.; Dijkstra, J.P.H.

    1991-01-01

    We report a study of technetium-99m-labelled carboxymethyl-cellulose ( 99m Tc-CMC) as a newly developed non-digestible marker of the solid phase of gastric contents. The radiosynthesis is simple and shows a high labelling efficiency. In vitro and in vivo experiments demonstrated stability of the marker in the gastrointestinal tract during the process of gastric emptying. The gastric half-emptying time in ten healthy volunteers of both sexes was 105±17 min (mean±SD). This rate of gastric emptying is similar to that of non-digestible solid-phase markers such as in vivo labelled 99m Tc-chicken liver or radio-iodinated cellulose. In comparison with digestible solid-phase markers such as 99m Tc-labelled pancake or 99m Tc-cooked egg, gastric emptying of 99m Tc-CMC occurred more slowly, confirming the expected behaviour of a non-digestible solid-phase marker. We conclude that 99m Tc-CMC has the advantage of a simple and rapid labelling procedure and may be useful for clinical studies of gastric emptying. (orig.)

  16. A Convenient Storage Rack for Graduated Cylinders

    Science.gov (United States)

    Love, Brian

    2004-01-01

    An attempt is made to find a solution to the occasional problem of a need for storing large numbers of graduated cylinders in many teaching and research laboratories. A design, which involves the creation of a series of parallel channels that are used to suspend inverted graduated cylinders by their bases, is proposed.

  17. Recent Developments in Fabrication of Direct Drive Cylinder Targets for Hydrodynamics Experiments at the OMEGA Laser

    International Nuclear Information System (INIS)

    Nobile, A.; Balkey, M.M.; Bartos, J.J.; Batha, S.H.; Day, R.D.; Elliott, J.E.; Elliott, N.E.; Gomez, V.M.; Hatch, D.J.; Lanier, N.E.; Fincke, J.R.; Manzanares, R.; Pierce, T.H.; Sandoval, D.L.; Schmidt, D.W.; Steckle, W.P.

    2004-01-01

    Experimental campaigns are being conducted at the 60 beam OMEGA laser at the University of Rochester's Laboratory for Laser Energetics to acquire data to validate hydrodynamic models in the high energy-density regime. This paper describes targets that have been developed and constructed for these experimental campaigns. Targets are 860 μm inner diameter by 2.2 mm length cylinders with 70 μm thick polymer ablator. On the ablator inner surface and located halfway along the axis of the cylinder is a 500 μm wide Al marker band. Band thicknesses in the range 8-16 microns are used. CH foam with densities in the range 30-90 mg/cc fills the inside of the cylinder. While these targets have been fabricated for years, several new improvements and features have recently been developed. Improvements include the use of epoxy instead of polystyrene for the ablator, and the use of electrodeposited Al for the marker band. A critical feature of the target is the surface feature that is placed on the marker band. Experiments are aimed at understanding the hydrodynamic behavior of imploding cylinders as a function of this surface feature. Recent development work has focused on production of engineered surface features on the target marker band. Using a fast tool servo on a diamond turning lathe, a wide range of specified surface features have been produced. This paper will address improvements to the cylinder targets as well as current development efforts

  18. The Sea is Not an Empty Space

    Science.gov (United States)

    Satiawan, P. R.

    2017-07-01

    This research departs from a unique phenomenon, where Indonesian local people, fisherman, in Sapeken sub-district, Sumenep regency, together are able to divide the sea space based on the existence of resources in it with local intelligence inherited from generation to generation. Fisherman in Sapeken sub-district have the spatial intelligence to identify the existence of a sea space called premises “Takat” and “Timpusu”. Those spaces however cannot be seen with the eye and merely as an empty space, until the community giving meaning and signing to the space and create the strong perceptual map that prove that the sea is not an empty space. In order to have such a rigorous finding, the researcher using phenomenology methodology that allowed researcher to explore more about the phenomenon.

  19. Effect of Diesel Engine Converted to Sequential Port Injection Compressed Natural Gas Engine on the Cylinder Pressure vs Crank Angle in Variation Engine Speeds

    OpenAIRE

    Semin; Abdul R. Ismail; Rosli A. Bakar

    2009-01-01

    The diesel engine converted to compressed natural gas (CNG) engine effect is lower in performance. Problem statement: The hypothesis is that the lower performance of CNG engine is caused by the effect of lower in engine cylinder pressure. Are the CNG engine is lower cylinder pressure than diesel engine? This research is conducted to investigate the cylinder pressure of CNG engine as a new engine compared to diesel engine as a baseline engine. Approach: The research approach in this study is b...

  20. Evaluation of coverage of enriched UF6 cylinder storage lots by existing criticality accident alarms

    International Nuclear Information System (INIS)

    Lee, B.L. Jr.; Dobelbower, M.C.; Woollard, J.E.; Sutherland, P.J.; Tayloe, R.W. Jr.

    1995-03-01

    The Portsmouth Gaseous Diffusion Plant (PORTS) is leased from the US Department of Energy (DOE) by the United States Enrichment Corporation (USEC), a government corporation formed in 1993. PORTS is in transition from regulation by DOE to regulation by the Nuclear Regulatory Commission (NRC). One regulation is 10 CFR Part 76.89, which requires that criticality alarm systems be provided for the site. PORTS originally installed criticality accident alarm systems in all building for which nuclear criticality accidents were credible. Currently, however, alarm systems are not installed in the enriched uranium hexafluoride (UF 6 ) cylinder storage lots. This report analyzes and documents the extent to which enriched UF 6 cylinder storage lots at PORTS are covered by criticality detectors and alarms currently installed in adjacent buildings. Monte Carlo calculations are performed on simplified models of the cylinder storage lots and adjacent buildings. The storage lots modelled are X-745B, X-745C, X745D, X-745E, and X-745F. The criticality detectors modelled are located in building X-343, the building X-344A/X-342A complex, and portions of building X-330 (see Figures 1 and 2). These criticality detectors are those located closest to the cylinder storage lots. Results of this analysis indicate that the existing criticality detectors currently installed at PORTS are largely ineffective in detecting neutron radiation from criticality accidents in most of the cylinder storage lots at PORTS, except sometimes along portions of their peripheries

  1. [Gastric emptying of a solid-liquid meal in normal subjects: validity of the labeling (99mTc) of chicken liver by a multipuncture technic].

    Science.gov (United States)

    Hostein, J; Capony, P; Busquet, G; Bost, R; Fournet, J

    1985-04-01

    For gastric emptying studies of a solid-liquid meal by the scintigraphic method, a valid isotope labeling method for each phase of the meal must be obtained. The aim of this study was to validate a simple chicken liver labeling method in normal subjects by multipuncture technic with 99mtechnetium. Labeling according to Meyer's method was chosen as a reference. Simultaneously, a study of the quality of liquid phase labeling by 111indium was done. The labeling process quality for each phase of the meal was assessed: a) in vitro, after incubation of the meal with human gastric juice (n = 12); b) in vivo, after meal ingestion and sequential collection of gastric contents by aspiration (n = 4). Furthermore, in 8 healthy volunteers, gastric emptying curves of the solid and liquid phases of the meal were determined scintigraphically and compared. Our results showed: a) for the solid phase: a good specificity of the marker, which was assessed in vitro and in vivo, after liver labeling with multipuncture technique (89 p. 100 and 92 p. 100 after 180 min, respectively); b) for the liquid phase: a good specificity of the marker in vitro and a poor specificity in vivo (82 p. 100 and 27 p. 100 after 180 min, respectively); c) similar half-gastric emptying times and cumulative percentages for the solid and liquid phases with both liver labeling methods. In conclusion, the multipuncture technique for chicken liver labeling may be used for gastric emptying studies in humans.

  2. A constant-density Gurney approach to the Cylinder test

    Energy Technology Data Exchange (ETDEWEB)

    Reaugh, John E.; Souers, P. Clark [Energetic Materials Center, Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States)

    2004-04-01

    The previous analysis of the Cylinder test required the treatment of different wall thicknesses and wall materials separately. To fix this, the Gurney analysis is used, but this results in low values for full-wall standard, ideal explosives relative to CHEETAH analyses. A new constant metal-density model is suggested, which takes account of the thinning metal wall as the cylinder expands. With this model, the inner radius of the metal cylinder moves faster than the measured outer radius. Additional small corrections occur in all cylinders because of energy trapped in the copper walls. Also, the half-wall cylinders have a small correction because the relative volumes of the gas products are smaller at a given outside wall displacement. The Fabry-Perot and streak camera measurements are compared. The Fabry method is shown to equate to the constant density model. (Abstract Copyright [2004], Wiley Periodicals, Inc.)

  3. SU-F-18C-11: Diameter Dependency of the Radial Dose Distribution in a Long Polyethylene Cylinder

    Energy Technology Data Exchange (ETDEWEB)

    Bakalyar, D; McKenney, S [Henry Ford Health System, Detroit, MI (United States); Feng, W [New York Presbyterian Hospital, Tenafly, NJ (United States)

    2014-06-15

    Purpose: The radial dose distribution in the central plane of a long cylinder following a long CT scan depends upon the diameter and composition of the cylinder. An understanding of this behavior is required for determining the spatial average of the dose in the central plane. Polyethylene, the material for construction of the TG200/ICRU phantom (30 cm in diameter) was used for this study. Size effects are germane to the principles incorporated in size specific dose estimates (SSDE); thus diameter dependency was explored as well. Method: ssuming a uniform cylinder and cylindrically symmetric conditions of irradiation, the dose distribution can be described using a radial function. This function must be an even function of the radial distance due to the conditions of symmetry. Two effects are accounted for: The direct beam makes its weakest contribution at the center while the contribution due to scatter is strongest at the center and drops off abruptly at the outer radius. An analytic function incorporating these features was fit to Monte Carlo results determined for infinite polyethylene cylinders of various diameters. A further feature of this function is that it is integrable. Results: Symmetry and continuity dictate a local extremum at the center which is a minimum for the larger sizes. The competing effects described above can Resultin an absolute maximum occurring between the center and outer edge of the cylinders. For the smallest cylinders, the maximum dose may occur at the center. Conclusion: An integrable, analytic function can be used to characterize the radial dependency of dose for cylindrical CT phantoms of various sizes. One use for this is to help determine average dose distribution over the central cylinder plane when equilibrium dose has been reached.

  4. Investigation on carbon nanomaterials: Coaxial CNT-cylinders and ...

    Indian Academy of Sciences (India)

    Wintec

    carbon cylinders of CNT stacks have been formed directly inside the quartz tube. Another study is ... producing CNTs have been devised including electric arc evaporation ... process of coaxial carbon cylinder have already been de- scribed by ...

  5. Adaptive individual-cylinder thermal state control using piston cooling for a GDCI engine

    Science.gov (United States)

    Roth, Gregory T; Husted, Harry L; Sellnau, Mark C

    2015-04-07

    A system for a multi-cylinder compression ignition engine includes a plurality of nozzles, at least one nozzle per cylinder, with each nozzle configured to spray oil onto the bottom side of a piston of the engine to cool that piston. Independent control of the oil spray from the nozzles is provided on a cylinder-by-cylinder basis. A combustion parameter is determined for combustion in each cylinder of the engine, and control of the oil spray onto the piston in that cylinder is based on the value of the combustion parameter for combustion in that cylinder. A method for influencing combustion in a multi-cylinder engine, including determining a combustion parameter for combustion taking place in in a cylinder of the engine and controlling an oil spray targeted onto the bottom of a piston disposed in that cylinder is also presented.

  6. Viability Study for an Unattended UF_6 Cylinder Verification Station: Phase I Final Report

    International Nuclear Information System (INIS)

    Smith, Leon E.; Miller, Karen A.; Garner, James R.; Branney, Sean; McDonald, Benjamin S.; Webster, Jennifer B.; Zalavadia, Mital A.; Todd, Lindsay C.; Kulisek, Jonathan A.; Nordquist, Heather; Deshmukh, Nikhil S.; Stewart, Scott

    2016-01-01

    In recent years, the International Atomic Energy Agency (IAEA) has pursued innovative techniques and an integrated suite of safeguards measures to address the verification challenges posed by the front end of the nuclear fuel cycle. Among the unattended instruments currently being explored by the IAEA is an Unattended Cylinder Verification Station (UCVS) that could provide automated, independent verification of the declared relative enrichment, "2"3"5U mass, total uranium mass and identification for all declared UF_6 cylinders in a facility (e.g., uranium enrichment plants and fuel fabrication plants). Under the auspices of the United States and European Commission Support Programs to the IAEA, a project was undertaken to assess the technical and practical viability of the UCVS concept. The US Support Program team consisted of Pacific Northwest National Laboratory (PNNL, lead), Los Alamos National Laboratory (LANL), Oak Ridge National Laboratory (ORNL) and Savanah River National Laboratory (SRNL). At the core of the viability study is a long-term field trial of a prototype UCVS system at a Westinghouse fuel fabrication facility. A key outcome of the study is a quantitative performance evaluation of two nondestructive assay (NDA) methods being considered for inclusion in a UCVS: Hybrid Enrichment Verification Array (HEVA), and Passive Neutron Enrichment Meter (PNEM). This report provides context for the UCVS concept and the field trial: potential UCVS implementation concepts at an enrichment facility; an overview of UCVS prototype design; field trial objectives and activities. Field trial results and interpretation are presented, with a focus on the performance of PNEM and HEVA for the assay of over 200 ''typical'' Type 30B cylinders, and the viability of an ''NDA Fingerprint'' concept as a high-fidelity means to periodically verify that the contents of a given cylinder are consistent with previous scans. A modeling study, combined with field-measured instrument

  7. Vortex shedding control of circular cylinder by perforated shroud in deep water

    Directory of Open Access Journals (Sweden)

    Ozkan Gokturk M.

    2017-01-01

    Full Text Available The aim of the present study is to control the vortex shedding downstream of a circular cylinder (inner cylinder by the existence of outer perforated cylinder concentrically located around the inner cylinder in deep water. The flow characteristics downstream of concentrically placed coupled cylinders were investigated quantitatively by the Particle Image Velocimetry (PIV technique. Diameter of the outer perforated cylinder and inner cylinder were kept constant as Do=100 mm and Di=50 mm. The depth-averaged free-stream velocity was also kept constant as U=100 mm/s which corresponded to the Reynolds number of ReDo=10,000 based on the outer cylinder diameter. Experiments were conducted for six porosities (β = 0.3, 0.4, 0.5, 0.6, 0.7 and 0.8 in order to show the effect of these parameters on the flow control. Maximum values of both Reynolds shear stress, and turbulence kinetic energy, significantly decreased with the existence of outer perforated cylinder and also, the location of peak magnitudes of turbulence statistics occurred at locations further downstream compared to the bare cylinder case. The most effective control was revealed for the porosity of β=0.7.

  8. Vortex shedding control of circular cylinder by perforated shroud in deep water

    Science.gov (United States)

    Ozkan, Gokturk M.; Durhasan, Tahir; Pinar, Engin; Aksoy, Muhammed M.; Akilli, Huseyin; Sahin, Beşir

    The aim of the present study is to control the vortex shedding downstream of a circular cylinder (inner cylinder) by the existence of outer perforated cylinder concentrically located around the inner cylinder in deep water. The flow characteristics downstream of concentrically placed coupled cylinders were investigated quantitatively by the Particle Image Velocimetry (PIV) technique. Diameter of the outer perforated cylinder and inner cylinder were kept constant as Do=100 mm and Di=50 mm. The depth-averaged free-stream velocity was also kept constant as U=100 mm/s which corresponded to the Reynolds number of ReDo=10,000 based on the outer cylinder diameter. Experiments were conducted for six porosities (β = 0.3, 0.4, 0.5, 0.6, 0.7 and 0.8) in order to show the effect of these parameters on the flow control. Maximum values of both Reynolds shear stress, and turbulence kinetic energy, significantly decreased with the existence of outer perforated cylinder and also, the location of peak magnitudes of turbulence statistics occurred at locations further downstream compared to the bare cylinder case. The most effective control was revealed for the porosity of β=0.7.

  9. AFM tip-sample convolution effects for cylinder protrusions

    Science.gov (United States)

    Shen, Jian; Zhang, Dan; Zhang, Fei-Hu; Gan, Yang

    2017-11-01

    A thorough understanding about the AFM tip geometry dependent artifacts and tip-sample convolution effect is essential for reliable AFM topographic characterization and dimensional metrology. Using rigid sapphire cylinder protrusions (diameter: 2.25 μm, height: 575 nm) as the model system, a systematic and quantitative study about the imaging artifacts of four types of tips-two different pyramidal tips, one tetrahedral tip and one super sharp whisker tip-is carried out through comparing tip geometry dependent variations in AFM topography of cylinders and constructing the rigid tip-cylinder convolution models. We found that the imaging artifacts and the tip-sample convolution effect are critically related to the actual inclination of the working cantilever, the tip geometry, and the obstructive contacts between the working tip's planes/edges and the cylinder. Artifact-free images can only be obtained provided that all planes and edges of the working tip are steeper than the cylinder sidewalls. The findings reported here will contribute to reliable AFM characterization of surface features of micron or hundreds of nanometers in height that are frequently met in semiconductor, biology and materials fields.

  10. Effect of Surface Coatings on Cylinders Exposed to Underwater Shock

    Directory of Open Access Journals (Sweden)

    Y.W. Kwon

    1994-01-01

    Full Text Available The response of a coated cylinder (metallic cylinder coated with a rubber material subjected to an underwater explosion is analyzed numerically. The dynamic response of the coated cylinder appears to be adversely affected when impacted by an underwater shock wave under certain conditions of geometry and material properties of the coating. When adversely affected, significant deviations in values of axial stress, hoop stress, and strain are observed. The coated cylinder exhibits a larger deformation and higher internal energy in the metallic material. Rubber coatings appeared to inhibit energy dissipation from the metallic material to the surrounding water medium. A parametric study of various coatings was performed on both aluminum and steel cylinders. The adverse effect of the coating decreased when the stiffness of the rubber layer increased, indicating the existence of a threshold value. The results of this study indicate that the stiffness of the coating is a critical factor to the shock hardening of the coated cylinder.

  11. Long-term storage of compressed radioactive krypton in cylinders

    International Nuclear Information System (INIS)

    Niephaus, D.; Nommensen, O.; Bruecher, H.

    1982-01-01

    The recommendations of the German Radiation Protection Commission necessitate the separation of the radioactive noble gas krypton-85 (Kr-85) produced in large LWR reprocessing plants from the dissolver off-gas. A possible method of removal is a long-term storage of the compressed noble gas above ground in cylinders. The aim of the present study is to develop such a storage concept and evaluate its feasibility under the aspects of safety and cost. After having been filled, the gas cylinders are placed separately into transport racks serving to protect the cylinders. Following this, the cylinders are transferred out of the filling station in a transport cask, conveyed to the storage building and stored there. The storage building protects the gas cylinders against external impacts. The storage cells constitute a second barrier against the release of Kr-85. The heat produced during decay of the Kr-85 in the gas cylinders is carried off by natural convection of the air circulating in the storage cells. To study possible corrosion attack on special steels due to rubidium, experiments were conducted at 200 0 C during test periods up to 3500h. In order to compare properties at elevated temperatures, corrosion experiments were conducted at 500 0 C, which is far above the maximum licensed storage temperature of 200 0 C. Experiments were conducted concerning the adsorption of krypton on various adsorbents, thus reducing the pressure inside the gas cylinder during storage. A cost estimate based on 1980 prices

  12. Influences of fat restriction and lipase inhibition on gastric emptying in obesity

    NARCIS (Netherlands)

    Mathus-Vliegen, E. M. H.; van Ierland-van Leeuwen, M. L.; Bennink, R. J.

    2006-01-01

    OBJECTIVE: Accelerated gastric emptying of solids may play a role in the pathogenesis of obesity. Orlistat, a potent lipase inhibitor, induces fat malabsorption and body weight loss but might accelerate gastric emptying as a result of suppressed CCK release. The aim was to investigate the role of

  13. Effect of High Porosity Screen on the Near Wake of a Circular Cylinder

    Directory of Open Access Journals (Sweden)

    Sahin B.

    2013-04-01

    Full Text Available The change in flow characteristics downstream of a circular cylinder (inner cylinder surrounded by a permeable cylinder (outer cylinder made of a high porosity screen was investigated in shallow water using Particle Image Velocimetry (PIV technique. The diameter of the inner cylinder, outer cylinder and the water height were kept constant during the experiments as d = 50 mm, D = 100 mm and hw = 50 mm, respectively. The depth-averaged free stream velocity was also kept constant as U = 180 mm/s which corresponded to a Reynolds number of Red = 9000 based on the inner cylinder diameter. It was shown that the outer permeable cylinder had a substantialeffect on the vortex formation and consequent vortex shedding downstream of the circular cylinder, especially in the near wake. The time averaged vorticity layers, streamlines and velocity vector field depict that the location of the interaction of vortices considerably changed by the presence of the outer cylinder. Turbulent statistics clearly demonstrated that in comparison to the natural cylinder, turbulent kinetic energy and Reynolds stresses decreased remarkably downstream of the inner cylinder. Moreover, spectra of streamwise velocity fluctuations showed that the vortex shedding frequency significantly reduced compared to the natural cylinder case.

  14. Sluggish gallbladder emptying and gastrointestinal transit after intake of common alcoholic beverages.

    Science.gov (United States)

    Kasicka-Jonderko, A; Jonderko, K; Gajek, E; Piekielniak, A; Zawislan, R

    2014-02-01

    To study the movement along the gut and the effect upon the gallbladder volume of alcoholic beverages taken in the interdigestive state. The study comprised three research blocks attended by 12 healthy subjects each. Within a given research block volunteers underwent three examination sessions held on separate days, being offered an alcoholic beverage, or an aqueous ethanol solution of an identical proof, or a corresponding volume of isotonic glucose solution; the order of administration of the drinks was randomized. The beverages tested were: beer (4.7% vol, 400 ml), red wine (13.7% vol, 200 ml), whisky (43.5% vol, 100 ml) within the "Beer", "Wine", and "Whisky" research block, respectively. Gastric myoelectrical activity was examined electrogastrographically, gastric emptying with ¹³C-sodium acetate breath test, orocaecal transit with lactulose H₂ breath test, gallbladder emptying with ultrasonography, breath ethanol with alcotest. The study showed that alcoholic beverages were emptied from the stomach significantly slower than isotonic glucose. Alcoholic beverages produced by fermentation only (beer, red wine) were emptied from the stomach more slowly than ethanol solutions of identical proof, while gastric evacuation of whisky (distillation product) and matching alcohol solution was similar. The slower gastric evacuation of alcoholic beverages and ethanol solutions could not be ascribed to a disorganization of the gastric myoelectrical activity. The orocaecal transit of beer and red wine did not differ from that of isotonic glucose, whereas the orocaecal transit of whisky and high proof ethanol was markedly prolonged. Red wine and whisky, and to a similar extent control ethanol solutions caused an inhibition and delay of gallbladder emptying. We concluded that alcoholic beverages taken on an empty stomach exert a suppressive effect upon the transport function of the digestive tract and gallbladder emptying. The extent of this action depends on the type of a

  15. 49 CFR 180.205 - General requirements for requalification of specification cylinders.

    Science.gov (United States)

    2010-10-01

    ... each cylinder tested, except that for an analog device, interpolation to 1/2 of the marked gauge... for training persons who requalify cylinders using the volumetric expansion test method. (h) Cylinder...

  16. Plane Wall Effect of Flow around Two Circular Cylinders in Tandem Arrangement

    Directory of Open Access Journals (Sweden)

    Triyogi Yuwono,

    2011-02-01

    Full Text Available The flow characteristic around two circular cylinders in tandem arrangement located near a plane wall were investigated experimentally in a uniform flow at a Reynolds Number of 5.3 x 104. The center to center spacing between the two cylinders relative to the cylinder diameter was constantly maintained at P/D = 1.5. The pressure distributions along the surface of the cylinder and the plane wall were measured by varying the gap-to-diameter of cylinder ratio (G/D in the range of 0 < G/D < 0.467. Surface oil-film techniques were used to investigate the flow patterns on the cylinder. The result showed that for upstream cylinder, in the gap-to-diameter ratio G/D < /D, there is no stagnation point at front side of the upstream cylinder; it is gradually raised as the gap increase. For the downstream cylinder, a peak on the lower side of the front side of the cylinder is apparent in each of the pressure distributions. This peak represents the reattachment of shear layer that separates from lower side of the upstream cylinder. The reattachment point tends to move forward close to the angular position of  = 0o as the gap ratio increase. The shear layer bifurcates into two shear layers. One shear layer continues in the downstream direction, and the other shear layer flows in the upstream direction.

  17. Experimental study on flow past a rotationally oscillating cylinder

    Science.gov (United States)

    Gao, Yang-yang; Yin, Chang-shan; Yang, Kang; Zhao, Xi-zeng; Tan, Soon Keat

    2017-08-01

    A series of experiments was carried out to study the flow behaviour behind a rotationally oscillating cylinder at a low Reynolds number (Re=300) placed in a recirculation water channel. A stepper motor was used to rotate the cylinder clockwise- and- counterclockwise about its longitudinal axis at selected frequencies. The particle image velocimetry (PIV) technique was used to capture the flow field behind a rotationally oscillating cylinder. Instantaneous and timeaveraged flow fields such as the vorticity contours, streamline topologies and velocity distributions were analyzed. The effects of four rotation angle and frequency ratios F r ( F r= f n/ f v, the ratio of the forcing frequency f n to the natural vortex shedding frequency f v) on the wake in the lee of a rotationally oscillating cylinder were also examined. The significant wake modification was observed when the cylinder undergoes clockwise-and-counterclockwise motion with amplitude of π, especially in the range of 0.6≤ F r≤1.0.

  18. Adaptive individual-cylinder thermal state control using intake air heating for a GDCI engine

    Science.gov (United States)

    Roth, Gregory T.; Sellnau, Mark C.

    2016-08-09

    A system for a multi-cylinder compression ignition engine includes a plurality of heaters, at least one heater per cylinder, with each heater configured to heat air introduced into a cylinder. Independent control of the heaters is provided on a cylinder-by-cylinder basis. A combustion parameter is determined for combustion in each cylinder of the engine, and control of the heater for that cylinder is based on the value of the combustion parameter for combustion in that cylinder. A method for influencing combustion in a multi-cylinder compression ignition engine, including determining a combustion parameter for combustion taking place in a cylinder of the engine and controlling a heater configured to heat air introduced into that cylinder, is also provided.

  19. Cracked lifting lug welds on ten-ton UF{sub 6} cylinders

    Energy Technology Data Exchange (ETDEWEB)

    Dorning, R.E. [Martin Marietta Energy Systems, Inc., Piketon, OH (United States)

    1991-12-31

    Ten-ton, Type 48X, UF{sub 6} cylinders are used at the Portsmouth Gaseous Diffusion Plant to withdraw enriched uranium hexafluoride from the cascade, transfer enriched uranium hexafluoride to customer cylinders, and feed enriched product to the cascade. To accomplish these activities, the cylinders are lifted by cranes and straddle carriers which engage the cylinder lifting lugs. In August of 1988, weld cracks on two lifting lugs were discovered during preparation to lift a cylinder. The cylinder was rejected and tagged out, and an investigating committee formed to determine the cause of cracking and recommend remedial actions. Further investigation revealed the problem may be general to this class of cylinder in this use cycle. This paper discusses the actions taken at the Portsmouth site to deal with the cracked lifting lug weld problem. The actions include inspection activities, interim corrective actions, metallurgical evaluation of cracked welds, weld repairs, and current monitoring/inspection program.

  20. Determination of gastric-emptying profiles in the rat: influence of oil structure and volume

    International Nuclear Information System (INIS)

    Palin, K.J.; Whalley, D.R.; Wilson, C.G.; Davis, S.S.; Phillips, A.J.

    1982-01-01

    A simple non-invasive technique was developed for the determination of the gastric-emptying rate of oils in rats, employing a gamma camera and 99m-Tc-sulphur colloid as the oil phase marker. Using this method the gastric emptying of 3 oils, arachis oil, Miglyol 812 and liquid paraffin, was investigated. It was shown that both the oil volume and chemcial structure altered the rate of gastric emptying. (Auth.)

  1. Determination of gastric-emptying profiles in the rat: influence of oil structure and volume

    Energy Technology Data Exchange (ETDEWEB)

    Palin, K.J.; Whalley, D.R.; Wilson, C.G.; Davis, S.S.; Phillips, A.J. (Nottingham Univ. (UK). Medical School)

    1982-11-01

    A simple non-invasive technique was developed for the determination of the gastric-emptying rate of oils in rats, employing a gamma camera and 99m-Tc-sulphur colloid as the oil phase marker. Using this method the gastric emptying of 3 oils, arachis oil, Miglyol 812 and liquid paraffin, was investigated. It was shown that both the oil volume and chemical structure altered the rate of gastric emptying.

  2. Guided Circumferential Waves in Layered Poroelastic Cylinders

    Directory of Open Access Journals (Sweden)

    Shah S.A.

    2016-12-01

    Full Text Available The present paper investigates the propagation of time harmonic circumferential waves in a two-dimensional hollow poroelastic cylinder with an inner shaft (shaft-bearing assembly. The hollow poroelastic cylinder and inner shaft are assumed to be infinite in axial direction. The outer surface of the cylinder is stress free and at the interface, between the inner shaft and the outer cylinder, it is assumed to be free sliding and the interfacial shear stresses are zero, also the normal stress and radial displacements are continuous. The frequency equation of guided circumferential waves for a permeable and an impermeable surface is obtained. When the angular wave number vanish the frequency equation of guided circumferential waves for a permeable and an impermeable surface degenerates and the dilatational and shear waves are uncoupled. Shear waves are independent of the nature of surface. The frequency equation of a permeable and an impermeable surface for bore-piston assembly is obtained as a particular case of the model under consideration when the outer radius of the hollow poroelastic cylinder tends to infinity. Results of previous studies are obtained as a particular case of the present study. Nondimensional frequency as a function of wave number is presented graphically for two types of models and discussed. Numerical results show that, in general, the first modes are linear for permeable and impermeable surfaces and the frequency of a permeable surface is more than that of an impermeable surface.

  3. Comparison of total and compartmental gastric emptying and antral motility between healthy men and women

    Energy Technology Data Exchange (ETDEWEB)

    Bennink, R.; Van den Maegdenbergh, V.; Roo, M. de; Mortelmans, L. [Department of Nuclear Medicine, UZ KU Leuven (Belgium); Peeters, M.; Geypens, B.; Rutgeerts, P. [Department of Gastroenterology, UZ KU Leuven (Belgium)

    1998-09-01

    There is increasing evidence of gender-related differences in gastric emptying. The purpose of this study was first, to confirm the difference in gastric emptying for both solid and liquid test meals between healthy men and women, and secondly, to investigate the origin of this difference by studying regional gastric emptying and antral motility. A standard gastric emptying test with additional compartmental (proximal and distal) evaluation and dynamic imaging of the antrum was performed in 20 healthy women studied during the first 10 days of the menstrual cycle, and in 31 healthy age-matched men. In concordance with previous reports, women had a longer half-emptying time for solids as compared to men (86.2{+-}5.1 vs 52.2{+-}2.9 min, P<0.05). In our observations this seemed to be related to a significantly prolonged lag phase and a significant decrease in terminal slope. Dynamical antral scintigraphy did not show a significant difference. The distribution of the test meal within the stomach (proximal vs distal) showed more early proximal retention in women as compared to men. The terminal slope of the distal somach was significantly lower in women. We did not observe a significant difference in gastric emptying of the liquid test meal between men and women. Gastric emptying of solids is significantly slower in healthy women as compared to men. These findings emphasise the importance of using different normal values for clinical and research purposes in gastric emptying scintigraphy in men and women. The difference could not be explained by antral motility alone. Increased proximal retention and a lower terminal emptying rate in women are observations to be further investigated. (orig.) With 5 figs., 2 tabs., 36 refs.

  4. 17 CFR 270.30b1-1 - Semi-annual report for registered management investment companies.

    Science.gov (United States)

    2010-04-01

    ... registered management investment companies. 270.30b1-1 Section 270.30b1-1 Commodity and Securities Exchanges....30b1-1 Semi-annual report for registered management investment companies. Every registered management... management investment company that has filed a registration statement with the Commission registering its...

  5. Effects of Elevated Temperatures on the Compressive Strength Capacity of Concrete Cylinders Confined with FRP Sheets: An Experimental Investigation

    Directory of Open Access Journals (Sweden)

    Sherif El-Gamal

    2015-01-01

    Full Text Available Due to their high strength, corrosion resistance, and durability, fiber reinforced polymers (FRP are very attractive for civil engineering applications. One of these applications is the strengthening of concrete columns with FRP sheets. The performance of this strengthening technique at elevated temperature is still questionable and needs more investigations. This research investigates the effects of exposure to high temperatures on the compressive strength of concrete cylinders wrapped with glass and carbon FRP sheets. Test specimens consisted of 30 unwrapped and 60 wrapped concrete cylinders. All specimens were exposed to temperatures of 100, 200, and 300°C for periods of 1, 2, and 3 hours. The compressive strengths of the unwrapped concrete cylinders were compared with their counterparts of the wrapped cylinders. For the unwrapped cylinders, test results showed that the elevated temperatures considered in this study had almost no effect on their compressive strength; however, the wrapped specimens were significantly affected, especially those wrapped with GFRP sheets. The compressive strength of the wrapped specimens decreased as the exposure period and the temperature level increased. After three hours of exposure to 300°C, a maximum compressive strength loss of about 25.3% and 37.9%, respectively, was recorded in the wrapped CFRP and GFRP specimens.

  6. Low-cost, low-weight CNG cylinder development. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Richards, Mark E.; Melford, K.; Wong, J.; Gambone, L.

    1999-09-01

    This program was established to develop and commercialize new high-strength steel-lined, composite hoop-wrapped compressed natural gas (CNG) cylinders for vehicular applications. As much as 70% of the cost of natural gas vehicles can be related to on-board natural gas storage costs. The cost and weight targets for this program represent significant savings in each characteristic when compared to comparable containers available at the initiation of the program. The program objectives were to optimize specific weight and cost goals, yielding CNG cylinders with dimensions that should, allowing for minor modifications, satisfy several vehicle market segments. The optimization process encompassed material, design, and process improvement. In optimizing the CNG cylinder design, due consideration was given to safety aspects relative to national, international, and vehicle manufacturer cylinder standards and requirements. The report details the design and development effort, encompassing plant modifications, material selection, design issues, tooling development, prototype development, and prototype testing. Extenuating circumstances prevented the immediate commercialization of the cylinder designs, though significant progress was made towards improving the cost and performance of CNG cylinders. A new low-cost fiber was successfully employed while the weight target was met and the cost target was missed by less than seven percent.

  7. Gastric emptying 16 to 26 years after treatment of infantile hypertrophic pyloric stenosis.

    Science.gov (United States)

    Lüdtke, F E; Bertus, M; Voth, E; Michalski, S; Lepsien, G

    1994-04-01

    Long-term follow-up was performed 16 to 26 years after conservative (group I, n = 18) and operative (group II, n = 38) treatment of 56 patients who had infantile hypertrophic pyloric stenosis (IHPS). The study encompassed the scintigraphic determination of gastric emptying rates for solids and liquids, an interview to obtain medical history and ascertain whether a current disorder of the upper gastrointestinal tract was present, and a clinical examination. Gastric emptying rates were measured on two different days for solids and liquids. The standard solid meal consisted of two scrambled eggs, two slices of toast, and 20 g of margarine. The gastric emptying rate for liquids was measured using 300 mL of apple juice. The scrambled eggs and apple juice were each marked with 2.2 MBq technetium 99m-sulphur-colloid. Two control collectives were used in this study; one group (physicians) served to create a reference curve for gastric emptying, and the other group, with the same age and gender distributions as those of the patients, served to evaluate the frequency of gastrointestinal complaints, by means of a questionnaire. There was no significant rate difference for gastric emptying between the patients treated conservatively or surgically and the controls. No association could be construed between the frequency of gastrointestinal symptoms or disorders and the gastric emptying rates for solids and liquids. The results presented here substantiate that clinically relevant disturbances of stomach motility after IHPS appear to be rare.

  8. Pit Latrine Emptying Behavior and Demand for Sanitation Services in Dar Es Salaam, Tanzania

    Directory of Open Access Journals (Sweden)

    Marion W. Jenkins

    2015-02-01

    Full Text Available Pit latrines are the main form of sanitation in unplanned areas in many rapidly growing developing cities. Understanding demand for pit latrine fecal sludge management (FSM services in these communities is important for designing demand-responsive sanitation services and policies to improve public health. We examine latrine emptying knowledge, attitudes, behavior, trends and rates of safe/unsafe emptying, and measure demand for a new hygienic latrine emptying service in unplanned communities in Dar Es Salaam (Dar, Tanzania, using data from a cross-sectional survey at 662 residential properties in 35 unplanned sub-wards across Dar, where 97% had pit latrines. A picture emerges of expensive and poor FSM service options for latrine owners, resulting in widespread fecal sludge exposure that is likely to increase unless addressed. Households delay emptying as long as possible, use full pits beyond what is safe, face high costs even for unhygienic emptying, and resort to unsafe practices like ‘flooding out’. We measured strong interest in and willingness to pay (WTP for the new pit emptying service at 96% of residences; 57% were WTP ≥U.S. $17 to remove ≥200 L of sludge. Emerging policy recommendations for safe FSM in unplanned urban communities in Dar and elsewhere are discussed.

  9. Theory of axially symmetric probes in a collisionless magnetoplasma: Aligned spheroids, finite cylinders, and disks

    International Nuclear Information System (INIS)

    Rubinstein, J.; Laframboise, J.G.

    1983-01-01

    A theory is presented for current collection by electrostatic probes in a collisionless, Maxwellian plasma containing a uniform magnetic field B, where the probes are spheroids or finite cylinders whose axis of symmetry is aligned with B, or disks perpendicular to B. The theory yields upper-bound and adiabatic-limit currents for the attracted particle species. For the repelled species, it yields upper and lower bounds. This work is an extension of existing theory for spherical probes by Rubinstein and Laframboise

  10. 38 CFR 18b.30 - Notice of hearing or opportunity for hearing.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Notice of hearing or opportunity for hearing. 18b.30 Section 18b.30 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) PRACTICE AND PROCEDURE UNDER TITLE VI OF THE CIVIL RIGHTS ACT OF 1964 AND PART 18 OF THIS CHAPTER Proceedings Before Hearin...

  11. Gastric emptying in patients with chronic fatigue syndrome

    International Nuclear Information System (INIS)

    Sand, A.; Hulstaert, J.; Wanet, P.; Uyttersprot, A.; Meirleir, K. de

    2002-01-01

    Chronic fatigue syndrome (CFS) is a debilitating chronic illness of unknown cause characterized by mental fatigue and sensorimotor disturbances. Moreover, gastrointestinal symptoms (GI) are frequently noticed in those patients. A possible cause could be a dysfunction of the NANC neurotransmitter system in which Vasoactive Intestinal Polypeptide and NO plays an important role in the speed of the gastric relaxation. The Aim of this study was to determine the prevalence of gastric motility disorder in CFS patients. Materials and Methods: 51 patients affected by CFS (45 females and 6 males; mean age 38.5 ± 14.7 y) were prospectively studied by a gastric emptying scintigraphy and the results compared with a control population. The patients were categorized in two clinical groups according to the severity criteria of Holmes and Fukuda (H/F - or H/F +). The presence of GI symptoms was noticed for each patient. Gastric emptying was assessed by the standard procedure according to the guidelines of the Belgian Society of Nuclear Medicine. The acquisition of a series of 10 static images in anterior and posterior projections was started after a test meal (1 fried egg + 20 Mbq Tc99m sulfur colloids, 2 pieces of bread and 125 ml of water). Geometric means were calculated after correction for the half-life of Tc99m and the gastric half-emptying time (T1/2) was determined for each patient. Results: A significantly prolonged T 1/2 was found in CFS patients (97.8 ± 41.6 min) compared to our control population (70 ± 15 min) independently of the presence of associated GI symptoms. (p<0.01) There was also a close relationship between the T1/2 and severity of the CFS disease: the gastric emptying time of the two CFS groups (according to the H/F criteria) were respectively 78.9 and 112.9 min. which is highly significant. (p<0.05). Conclusion: We conclude that delayed gastric emptying is frequently encountered in patients with CFS (with mild or severe symptoms of gastroparesis) which

  12. Convective heat transfer from a heated elliptic cylinder at uniform wall temperature

    Energy Technology Data Exchange (ETDEWEB)

    Kaprawi, S.; Santoso, Dyos [Mechanical Department of Sriwijaya University, Jl. Raya Palembang-Prabumulih Km. 32 Inderalaya 50062 Ogan Ilir (Indonesia)

    2013-07-01

    This study is carried out to analyse the convective heat transfer from a circular and an elliptic cylinders to air. Both circular and elliptic cylinders have the same cross section. The aspect ratio of cylinders range 0-1 are studied. The implicit scheme of the finite difference is applied to obtain the discretized equations of hydrodynamic and thermal problem. The Choleski method is used to solve the discretized hydrodynamic equation and the iteration method is applied to solve the discretized thermal equation. The circular cylinder has the aspect ratio equal to unity while the elliptical cylinder has the aspect ratio less than unity by reducing the minor axis and increasing the major axis to obtain the same cross section as circular cylinder. The results of the calculations show that the skin friction change significantly, but in contrast with the elliptical cylinders have greater convection heat transfer than that of circular cylinder. Some results of calculations are compared to the analytical solutions given by the previous authors.

  13. Delayed gastric emptying of both the liquid and solid components of a meal in chronic liver disease.

    Science.gov (United States)

    Galati, J S; Holdeman, K P; Dalrymple, G V; Harrison, K A; Quigley, E M

    1994-05-01

    To evaluate gastric emptying in patients with chronic liver disease and portal hypertension. We measured gastric emptying of both the liquid and solid components of a meal in 10 consecutive patients with chronic liver disease and portal hypertension, but free of ascites, and 14 age- and sex-matched healthy controls. In the patients with liver disease, relationships between emptying and liver function were examined. To measure gastric emptying, subjects consumed a test meal that consisted of scrambled eggs labeled with 99mTc-sulfur colloid and 4 oz of water labeled with 111In-diethylene triamine pentacetic acid (DTPA). Patients with liver disease and portal hypertension demonstrated delayed emptying of both the liquid (t1/2, min, mean +/- SE, patients vs. 69.4 +/- 19.4 vs. 31.4 +/- 1.8, p < 0.01) and solid (post-lag phase solid emptying: 141 +/- 32.9 vs. 69.8 +/- 4.6, p < 0.006) components of the meal. We could not identify any correlation between gastric emptying and tests of liver function. Gastric emptying is delayed in patients with liver disease and portal hypertension; this abnormal gastric motor function may contribute to the pathophysiology of foregut complaints in this patient population.

  14. Quantitative flow characteristics for side-by-side square cylinders via PIV

    Directory of Open Access Journals (Sweden)

    Dogan Sercan

    2012-04-01

    Full Text Available In this study, instantaneous and time-averaged flow structures downstream of the sharp-edged single and two and three side-by-side square cylinders (SCs immersed in a uniform open channel water flow were studied by a technique of particle image velocimetry (PIV. Experimental results of wake flow structures were presented for gap ratios (G/D in the range of 1.0”G/D”3.0 for Reynolds number values of 1050, 2450 and 3400. Flow structures depending on the square cylinder (SC configurations and Reynolds number were discussed. It has been found that the development of the vortex shedding as well as the flow structure were substantially altered for side-by-side SCs comparing to the single SC. Asymmetrical and biased wake structures were observed because of the jetlike flow between the SCs for two SCs cases for the gap ratio less than 2.0. Depending on the gap spacing between the SCs, the interaction results of time2 averaged vorticity, velocity vector field, Reynolds stress correlations and streamline patterns in the wake region form a distinguished flow structure. Strouhal numbers for the single square cylinder for 1050≤Re≤3400 are found in the range of 0.12-0.13. The present results have supported the previous works by providing detailed quantitative experimental information with PIV in the wake region of the SC and might be helpful for validation of numerical studies and designers.

  15. Cylinder gauge measurement using a position sensitive detector

    International Nuclear Information System (INIS)

    St John, W. Doyle

    2007-01-01

    A position sensitive detector (PSD) has been used to determine the diameter of cylindrical pins based on the shift in a laser beam's centroid. The centroid of the light beam is defined here as the weighted average of position by the local intensity. A shift can be observed in the centroid of an otherwise axially symmetric light beam, which is partially obstructed. Additionally, the maximum shift in the centroid is a unique function of the obstructing cylinder diameter. Thus to determine the cylinder diameter, one only needs to detect this maximum shift as the cylinder is swept across the beam

  16. Experimental and finite element prediction of bursting pressure in compound cylinders

    International Nuclear Information System (INIS)

    Majzoobi, G.H.; Farrahi, G.H.; Pipelzadeh, M.K.; Akbari, A.

    2004-01-01

    Aluminium cylinders with a constant ratio of outer to inner radii, k=2.2, with different diametral interferences and various shrinkage radii were subjected to bursting and autofrettage pressures. Numerical simulations of the compound cylinders were also performed using the finite element code, NISA. The results can predict the optimum shrinkage radius to a reasonable accuracy with the use of finite element analysis. This radius corresponds to the situation when the maximum von-Mises stress at the internal radii of both the inner and outer cylinders become equal. It was shown that the maximum von-Mises stress across the wall of the cylinder is at the minimum at this shrinkage radius. The optimum diametral interference was found to be that which sufficiently brought the contact surface of the inner and outer cylinders to the point of yielding. Should the shrinkage pressure exceed the elastic limit, the pressure capacity of the cylinder will not be improved. The numerical and experimental results show that autofrettage had no effect on the bursting pressure of the thick-walled compound cylinder for the material tested

  17. Nationwide standardisation and evaluation of scintigraphic gastric emptying: reference values and comparisons between subgroups in a multicentre trial

    International Nuclear Information System (INIS)

    Grybaeck, P.; Hermansson, G.; Lyrenaes, E.; Beckman, K.-W.; Jacobsson, H.; Hellstroem, P.M.

    2000-01-01

    By means of a standardised procedure, reference values for scintigraphic gastric emptying were established. The influence of gender, age, menstrual cycle, body mass index (BMI) and smoking habits was also evaluated. Eight centres recruited 20 healthy subjects each. The meal consisted of a technetium-99m labelled omelet (1300 kJ) and of 150 ml unlabelled soft drink. Geometric means of frontal and dorsal acquisitions were utilised in a linear fit model for determination of the linear emptying rate, and by using the intercepts of the regression line with the 90% and 50% levels, the lag phase and half-emptying time, respectively, were defined. All individuals showed an initial lag phase and subsequent linear emptying. Because of a longer lag phase and a slower linear emptying rate, premenopausal women had a slower gastric emptying than postmenopausal women and men of all ages. The gastric emptying rate increased with age in the women, mainly due to a shortened lag phase, while the emptying rate remained almost unchanged with age in the males. There were no significant differences in results between the centres. The menstrual cycle, BMI and smoking habits did not affect emptying. In conclusion, the fact that the results showed a slower gastric emptying rate in younger women compared with older women and men indicates that it is necessary to use separate reference values for fertile females. (orig.)

  18. Nationwide standardisation and evaluation of scintigraphic gastric emptying: reference values and comparisons between subgroups in a multicentre trial

    Energy Technology Data Exchange (ETDEWEB)

    Grybaeck, P. [Department of Radiology, Karolinska Hospital, Stockholm (Sweden); Hermansson, G. [Department of Clinical Physiology, Oestra Hospital, Goeteborg (Sweden); Lyrenaes, E. [Department of Medicine, Blekinge Hospital, Karlskrona (Sweden); Beckman, K.-W. [Hospital Physics, Oerebro Hospital (Sweden); Jacobsson, H. [Department of Radiology, Karolinska Hospital, Stockholm (Sweden); Department of Nuclear Medicine, Karolinska Hospital, Stockholm (Sweden); Hellstroem, P.M. [Department of Gastroenterology and Hepatology, Karolinska Hospital, Stockholm (Sweden)

    2000-06-01

    By means of a standardised procedure, reference values for scintigraphic gastric emptying were established. The influence of gender, age, menstrual cycle, body mass index (BMI) and smoking habits was also evaluated. Eight centres recruited 20 healthy subjects each. The meal consisted of a technetium-99m labelled omelet (1300 kJ) and of 150 ml unlabelled soft drink. Geometric means of frontal and dorsal acquisitions were utilised in a linear fit model for determination of the linear emptying rate, and by using the intercepts of the regression line with the 90% and 50% levels, the lag phase and half-emptying time, respectively, were defined. All individuals showed an initial lag phase and subsequent linear emptying. Because of a longer lag phase and a slower linear emptying rate, premenopausal women had a slower gastric emptying than postmenopausal women and men of all ages. The gastric emptying rate increased with age in the women, mainly due to a shortened lag phase, while the emptying rate remained almost unchanged with age in the males. There were no significant differences in results between the centres. The menstrual cycle, BMI and smoking habits did not affect emptying. In conclusion, the fact that the results showed a slower gastric emptying rate in younger women compared with older women and men indicates that it is necessary to use separate reference values for fertile females. (orig.)

  19. PIV Measurements of He II Counterflow Around a Cylinder

    International Nuclear Information System (INIS)

    Fuzier, S.; Van Stiver, S. W.; Zhang, T.

    2006-01-01

    The induced flow field of counterflow He II across a circular cylinder has been quantitatively studied using the particle image velocimetry (PIV) technique. Two different size cylinders (6.35 mm and 2 mm in diameter) were used and placed in a 20 mm wide rectangular channel. In these experiments, large-scale eddy motion generated by the He II counterflow was observed both in front of and behind the cylinder, an effect which has no analogue in classical fluids

  20. Characterization of complete particles (VSV-G/SIN-GFP) and empty particles (VSV-G/EMPTY) in human immunodeficiency virus type 1-based lentiviral products for gene therapy: potential applications for improvement of product quality and safety.

    Science.gov (United States)

    Zhao, Yuan; Keating, Kenneth; Dolman, Carl; Thorpe, Robin

    2008-05-01

    Lentiviral vectors persist in the host and are therefore ideally suited for long-term gene therapy. To advance the use of lentiviral vectors in humans, improvement of their production, purification, and characterization has become increasingly important and challenging. In addition to cellular contaminants derived from packaging cells, empty particles without therapeutic function are the major impurities that compromise product safety and efficacy. Removal of empty particles is difficult because of their innate similarity in particle size and protein composition to the complete particles. We propose that comparison of the properties of lentiviral products with those of purposely expressed empty particles may reveal potential differences between empty and complete particles. For this, three forms of recombinant lentiviral samples, that is, recombinant vesicular stomatitis virus glycoprotein (VSV-G) proteins, empty particles (VSV-G/Empty), and complete particles (VSV-G/SIN-GFP) carrying viral RNA, were purified by size-exclusion chromatography (SEC). The SEC-purified samples were further analyzed by immunoblotting with six antibodies to examine viral and cellular proteins associated with the particles. This study has demonstrated, for the first time, important differences between VSV-G/Empty particles and complete VSV-G/SIN-GFP particles. Differences include the processing of Gag protein and the inclusion of cellular proteins in the particles. Our findings support the development of improved production, purification, and characterization methods for lentiviral products.