WorldWideScience

Sample records for emitter 213bi-labeled herceptin

  1. Alpha radioisotopes Ac-225 and Bi-213: a production and labelling of antibodies and peptides for clinical use

    Energy Technology Data Exchange (ETDEWEB)

    Bruchertseifer, Frank, E-mail: frank.bruchertseifer@ec.europa.eu [European Commission, Joint Research Centre, Karlsruhe (Germany)

    2017-07-01

    Full text: In various preclinical and clinical works the potential of the alpha emitters {sup 225}Ac and {sup 213}Bi as therapeutic radionuclides for application in targeted alpha therapy of cancer and infectious diseases was demonstrated. Both alpha emitters are available with high specific activity from established radionuclide generators. Their favorable chemical and physical properties have led to the conduction of a large number of preclinical studies and several clinical trials, demonstrating the feasibility, safety and therapeutic efficacy of targeted alpha therapy with {sup 225}Ac and {sup 213}Bi. This presentation will give an overview about the methods for the production of {sup 225}Ac and {sup 213}Bi, the {sup 225}Ac/{sup 213}Bi radionuclide generator systems, labelling of peptides and antibodies with {sup 225}Ac and {sup 213}Bi and relevant in vivo and in vitro works. (author)

  2. Comparison of therapeutic efficacy and biodistribution of 213Bi- and 211At-labeled monoclonal antibody MX35 in an ovarian cancer model

    DEFF Research Database (Denmark)

    Gustafsson, Anna M E; Bäck, Tom; Elgqvist, Jörgen

    2012-01-01

    The purpose of this study was to compare the therapeutic efficacy and biodistribution of the monoclonal antibody MX35 labeled with either (213)Bi or (211)At, both α-emitters, in an ovarian cancer model.......The purpose of this study was to compare the therapeutic efficacy and biodistribution of the monoclonal antibody MX35 labeled with either (213)Bi or (211)At, both α-emitters, in an ovarian cancer model....

  3. Optimizing labelling conditions of 213Bi-DOTATATE for preclinical applications of peptide receptor targeted alpha therapy.

    Science.gov (United States)

    Chan, Ho Sze; de Blois, Erik; Konijnenberg, Mark W; Morgenstern, Alfred; Bruchertseifer, Frank; Norenberg, Jeffrey P; Verzijlbergen, Fred J; de Jong, Marion; Breeman, Wouter A P

    2017-01-01

    213 Bismuth ( 213 Bi, T 1/2 = 45.6 min) is one of the most frequently used α-emitters in cancer research. High specific activity radioligands are required for peptide receptor radionuclide therapy. The use of generators containing less than 222 MBq 225 Ac (actinium), due to limited availability and the high cost to produce large-scale 225 Ac/ 213 Bi generators, might complicate in vitro and in vivo applications though.Here we present optimized labelling conditions of a DOTA-peptide with an 225 Ac/ 213 Bi generator (< 222 MBq) for preclinical applications using DOTA-Tyr 3 -octreotate (DOTATATE), a somatostatin analogue. The following labelling conditions of DOTATATE with 213 Bi were investigated; peptide mass was varied from 1.7 to 7.0 nmol, concentration of TRIS buffer from 0.15 mol.L -1 to 0.34 mol.L -1 , and ascorbic acid from 0 to 71 mmol.L -1 in 800 μL. All reactions were performed at 95 °C for 5 min. After incubation, DTPA (50 nmol) was added to stop the labelling reaction. Besides optimizing the labelling conditions, incorporation yield was determined by ITLC-SG and radiochemical purity (RCP) was monitored by RP-HPLC up to 120 min after labelling. Dosimetry studies in the reaction vial were performed using Monte Carlo and in vitro clonogenic assay was performed with a rat pancreatic tumour cell line, CA20948. At least 3.5 nmol DOTATATE was required to obtain incorporation ≥ 99 % with 100 MBq 213 Bi (at optimized pH conditions, pH 8.3 with 0.15 mol.L -1 TRIS) in a reaction volume of 800 μL. The cumulative absorbed dose in the reaction vial was 230 Gy/100 MBq in 30 min. A minimal final concentration of 0.9 mmol.L -1 ascorbic acid was required for ~100 MBq (t = 0) to minimize radiation damage of DOTATATE. The osmolarity was decreased to 0.45 Osmol/L.Under optimized labelling conditions, 213 Bi-DOTATATE remained stable up to 2 h after labelling, RCP was ≥ 85 %. In vitro showed a negative correlation between ascorbic acid

  4. In Vitro comparison of 213Bi- and 177Lu-radiation for peptide receptor radionuclide therapy.

    Science.gov (United States)

    Chan, Ho Sze; de Blois, Erik; Morgenstern, Alfred; Bruchertseifer, Frank; de Jong, Marion; Breeman, Wouter; Konijnenberg, Mark

    2017-01-01

    Absorbed doses for α-emitters are different from those for β-emitters, as the high linear energy transfer (LET) nature of α-particles results in a very dense energy deposition over a relatively short path length near the point of emission. This highly localized and therefore high energy deposition can lead to enhanced cell-killing effects at absorbed doses that are non-lethal in low-LET type of exposure. Affinities of DOTA-DPhe1-Tyr3-octreotate (DOTATATE), 115In-DOTATATE, 175Lu-DOTATATE and 209Bi-DOTATATE were determined in the K562-SST2 cell line. Two other cell lines were used for radiation response assessment; BON and CA20948, with a low and high expression of somatostatin receptors, respectively. Cellular uptake kinetics of 111In-DOTATATE were determined in CA20948 cells. CA20948 and BON were irradiated with 137Cs, 177Lu-DTPA, 177Lu-DOTATATE, 213Bi-DTPA and 213Bi-DOTATATE. Absorbed doses were calculated using the MIRDcell dosimetry method for the specific binding and a Monte Carlo model of a cylindrical 6-well plate geometry for the exposure by the radioactive incubation medium. Absorbed doses were compared to conventional irradiation of cells with 137Cs and the relative biological effect (RBE) at 10% survival was calculated. IC50 of (labelled) DOTATATE was in the nM range. Absorbed doses up to 7 Gy were obtained by 5.2 MBq 213Bi-DOTATATE, in majority the dose was caused by α-particle radiation. Cellular internalization determined with 111In-DOTATATE showed a linear relation with incubation time. Cell survival after exposure of 213Bi-DTPA and 213Bi-DOTATATE to BON or CA20948 cells showed a linear-exponential relation with the absorbed dose, confirming the high LET character of 213Bi. The survival of CA20948 after exposure to 177Lu-DOTATATE and the reference 137Cs irradiation showed the typical curvature of the linear-quadratic model. 10% Cell survival of CA20948 was reached at 3 Gy with 213Bi-DOTATATE, a factor 6 lower than the 18 Gy found for 177Lu

  5. In Vitro comparison of 213Bi- and 177Lu-radiation for peptide receptor radionuclide therapy.

    Directory of Open Access Journals (Sweden)

    Ho Sze Chan

    Full Text Available Absorbed doses for α-emitters are different from those for β-emitters, as the high linear energy transfer (LET nature of α-particles results in a very dense energy deposition over a relatively short path length near the point of emission. This highly localized and therefore high energy deposition can lead to enhanced cell-killing effects at absorbed doses that are non-lethal in low-LET type of exposure. Affinities of DOTA-DPhe1-Tyr3-octreotate (DOTATATE, 115In-DOTATATE, 175Lu-DOTATATE and 209Bi-DOTATATE were determined in the K562-SST2 cell line. Two other cell lines were used for radiation response assessment; BON and CA20948, with a low and high expression of somatostatin receptors, respectively. Cellular uptake kinetics of 111In-DOTATATE were determined in CA20948 cells. CA20948 and BON were irradiated with 137Cs, 177Lu-DTPA, 177Lu-DOTATATE, 213Bi-DTPA and 213Bi-DOTATATE. Absorbed doses were calculated using the MIRDcell dosimetry method for the specific binding and a Monte Carlo model of a cylindrical 6-well plate geometry for the exposure by the radioactive incubation medium. Absorbed doses were compared to conventional irradiation of cells with 137Cs and the relative biological effect (RBE at 10% survival was calculated.IC50 of (labelled DOTATATE was in the nM range. Absorbed doses up to 7 Gy were obtained by 5.2 MBq 213Bi-DOTATATE, in majority the dose was caused by α-particle radiation. Cellular internalization determined with 111In-DOTATATE showed a linear relation with incubation time. Cell survival after exposure of 213Bi-DTPA and 213Bi-DOTATATE to BON or CA20948 cells showed a linear-exponential relation with the absorbed dose, confirming the high LET character of 213Bi. The survival of CA20948 after exposure to 177Lu-DOTATATE and the reference 137Cs irradiation showed the typical curvature of the linear-quadratic model. 10% Cell survival of CA20948 was reached at 3 Gy with 213Bi-DOTATATE, a factor 6 lower than the 18 Gy found

  6. 213Bi-DOTATOC receptor-targeted alpha-radionuclide therapy induces remission in neuroendocrine tumours refractory to beta radiation: a first-in-human experience

    International Nuclear Information System (INIS)

    Kratochwil, C.; Giesel, F.L.; Mier, W.; Haberkorn, U.; Bruchertseifer, F.; Apostolidis, C.; Morgenstern, A.; Boll, R.; Murphy, K.

    2014-01-01

    Radiopeptide therapy using a somatostatin analogue labelled with a beta emitter such as 90 Y/ 177 Lu-DOTATOC is a new therapeutic option in neuroendocrine cancer. Alternative treatments for patients with refractory disease are rare. Here we report the first-in-human experience with 213 Bi-DOTATOC targeted alpha therapy (TAT) in patients pretreated with beta emitters. Seven patients with progressive advanced neuroendocrine liver metastases refractory to treatment with 90 Y/ 177 Lu-DOTATOC were treated with an intraarterial infusion of 213 Bi-DOTATOC, and one patient with bone marrow carcinosis was treated with a systemic infusion of 213 Bi-DOTATOC. Haematological, kidney and endocrine toxicities were assessed according to CTCAE criteria. Radiological response was assessed with contrast-enhanced MRI and 68 Ga-DOTATOC-PET/CT. More than 2 years of follow-up were available in seven patients. The biodistribution of 213 Bi-DOTATOC was evaluable with 440 keV gamma emission scans, and demonstrated specific tumour binding. Enduring responses were observed in all treated patients. Chronic kidney toxicity was moderate. Acute haematotoxicity was even less pronounced than with the preceding beta therapies. TAT can induce remission of tumours refractory to beta radiation with favourable acute and mid-term toxicity at therapeutic effective doses. (orig.)

  7. {sup 213}Bi-DOTATOC receptor-targeted alpha-radionuclide therapy induces remission in neuroendocrine tumours refractory to beta radiation: a first-in-human experience

    Energy Technology Data Exchange (ETDEWEB)

    Kratochwil, C.; Giesel, F.L.; Mier, W.; Haberkorn, U. [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); Bruchertseifer, F.; Apostolidis, C.; Morgenstern, A. [European Commission, Institute for Transuranium Elements, Karlsruhe (Germany); Boll, R.; Murphy, K. [Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    2014-11-15

    Radiopeptide therapy using a somatostatin analogue labelled with a beta emitter such as {sup 90}Y/{sup 177}Lu-DOTATOC is a new therapeutic option in neuroendocrine cancer. Alternative treatments for patients with refractory disease are rare. Here we report the first-in-human experience with {sup 213}Bi-DOTATOC targeted alpha therapy (TAT) in patients pretreated with beta emitters. Seven patients with progressive advanced neuroendocrine liver metastases refractory to treatment with {sup 90}Y/{sup 177}Lu-DOTATOC were treated with an intraarterial infusion of {sup 213}Bi-DOTATOC, and one patient with bone marrow carcinosis was treated with a systemic infusion of {sup 213}Bi-DOTATOC. Haematological, kidney and endocrine toxicities were assessed according to CTCAE criteria. Radiological response was assessed with contrast-enhanced MRI and {sup 68}Ga-DOTATOC-PET/CT. More than 2 years of follow-up were available in seven patients. The biodistribution of {sup 213}Bi-DOTATOC was evaluable with 440 keV gamma emission scans, and demonstrated specific tumour binding. Enduring responses were observed in all treated patients. Chronic kidney toxicity was moderate. Acute haematotoxicity was even less pronounced than with the preceding beta therapies. TAT can induce remission of tumours refractory to beta radiation with favourable acute and mid-term toxicity at therapeutic effective doses. (orig.)

  8. Bismuth 213-labeled anti-CD45 radioimmunoconjugate to condition dogs for nonmyeloablative allogeneic marrow grafts

    Energy Technology Data Exchange (ETDEWEB)

    Sandmaier, B M.(Fred Hutchinson Cancer Research Center, Seattle, WA); Bethge, W A.(Fred Hutchinson Cancer Research Center, Seattle, WA); Wilbur, D. Scott (Washington, Univ Of); Hamlin, Donald K.(Washington, Univ Of); Santos, E B.(Fred Hutchinson Cancer Research Center, Seattle, WA); Brechbiel, M W.(National Cancer Institute, National Institutes of Health, Bethesda, MD); Fisher, Darrell R.(BATTELLE (PACIFIC NW LAB)); Storb, R. (Fred Hutchinson Cancer Research Center)

    2002-01-01

    To lower treatment-related mortality and toxicity of conventional marrow transplantation, a nonmyeloablative regimen using 200 cGy total-body irradiation (TBI) and mycophenolate mofetil (MMF) combined with cyclosporine (CSP) for postgrafting immunosuppression was developed. To circumvent possible toxic effects of external- beam gamma irradiation, strategies for targeted radiation therapy were investigated. We tested whether the short-lived (46 minutes) alpha-emitter Bi-213 conjugated to an anti-CD45 monoclonal antibody (mAb) could replace 200 cGy TBI and selectively target hematopoietic tissues in a canine model of nonmyeloablative DLA-identical marrow transplantation. Biodistribution studies using iodine 123-labeled anti-CD45 mAb showed uptake in blood, marrow, lymph nodes, spleen, and liver. In a dose-escalation study, 7 dogs treated with the Bi-213-anti-CD45 conjugate (Bi-213 dose, 0.1-5.9 mCi/kg[3.7-218 MBq/kg]) without marrow grafts had no toxic effects other than a mild, reversible suppression of blood counts. On the basis of these studies, 3 dogs were treated with 0.5 mg/kg Bi-213-labeled anti-CD45 mAb (Bi-213 doses, 3.6, 4.6, and 8.8 mCi/kg[133, 170, and 326 MBq/kg]) given in 6 injections 3 and 2 days before grafting of marrow from DLA-identical littermates. The dogs also received MMF (10 mg/kg subcutaneously twice daily the day of transplantation until day 27 afterward) and CSP (15 mg/kg orally twice daily the day before transplantation until 35 days afterward). Therapy was well tolerated except for transient elevations in levels of transaminases in 3 dogs, followed by, in one dog, ascites. All dogs achieved prompt engraftment and stable mixed hematopoietic chimerism, with donor contributions ranging from 30% to 70% after more than 27 weeks of follow-up. These results form the basis for additional studies in animals and the design of clinical trials using Bi-213 as a nonmyeloablative conditioning regimen with minimal toxicity.

  9. Somatostatin-receptor-targeted α-emitting 213Bi is therapeutically more effective than β--emitting 177Lu in human pancreatic adenocarcinoma cells

    International Nuclear Information System (INIS)

    Nayak, Tapan K.; Norenberg, Jeffrey P.; Anderson, Tamara L.; Prossnitz, Eric R.; Stabin, Michael G.; Atcher, Robert W.

    2007-01-01

    Introduction: Advance clinical cancer therapy studies of patients treated with somatostatin receptor (sstr)-targeted [DOTA 0 -Tyr 3 ]octreotide (DOTATOC) labeled with low-linear-energy-transfer (LET) β - -emitters have shown overall response rates in the range of 15-33%. In order to improve outcomes, we sought to compare the therapeutic effectiveness of sstr-targeted high-LET α-emitting 213 Bi to that of low-LET β - -emitting 177 Lu by determining relative biological effectiveness (RBE) using the external γ-beam of 137 Cs as reference radiation. Methods: Sstr-expressing human pancreatic adenocarcinoma Capan-2 cells and A549 control cells were used for this study. The effects of different radiation doses of 213 Bi and 177 Lu labeled to 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid and sstr-targeted DOTATOC were investigated with a clonogenic cell survival assay. Apoptosis was measured using the Cell Death Detection ELISA PLUS 10x kit. Results: Using equimolar DOTATOC treatment with concurrent irradiation with a 137 Cs source as reference radiation, the calculated RBE of [ 213 Bi]DOTATOC was 3.4, as compared to 1.0 for [ 177 Lu]DOTATOC. As measured in terms of absorbance units, [ 213 Bi]DOTATOC caused a 2.3-fold-greater release of apoptosis-specific mononucleosomes and oligonucleosomes than [ 177 Lu]DOTATOC at the final treatment time of 96 h (P 213 Bi]DOTATOC is therapeutically more effective in decreasing survival than is [ 177 Lu]DOTATOC in human pancreatic adenocarcinoma cells due to its comparatively higher RBE

  10. Experimental Treatment of Bladder Cancer with Bi-213-anti-EGFR MAb

    International Nuclear Information System (INIS)

    Seidl, Christof; Pfost, Birgit; Müller, Felix

    2013-01-01

    Therapy of non-muscle-invasive bladder cancer (carcinoma in situ) comprises transurethral resection of the tumour and subsequent instillation of the chemotherapeutic drug mitomycin C in order to eradicate remaining tumour cells. Yet 15 – 40% of treated patients relapse within 5 years. Therefore, new therapeutic strategies to combat tumour recurrence are needed. Alpha-particle emitting radionuclides efficiently kill single tumour cells or small tumour cell clusters. Because the epidermal growth factor receptor (EGFR) is overexpressed on bladder cancer cells, conjugates composed of the alpha-emitter Bi-213 and the anti-EGFR antibody matuzumab should provide a powerful drug to eliminate disseminated bladder cancer cells. Therefore, the aims of our study were (i) to analyse the cytotoxic effects of Bi-213-anti-EGFR radioimmunoconjugates at the cellular level, (ii) to evaluate therapeutic efficacy of intravesically applied Bi-213- anti-EGFR-Mab in a nude mouse model with intravesical human bladder cancer xenografts, (iii) to compare Bi- 213-anti-EGFR-Mab efficacy with chemotherapy using mitomycin C and (iv) to demonstrate that radioimmunotherapy is not toxic to cells of the bladder wall and of the kidneys

  11. Therapeutic efficacy and toxicity of {sup 225}Ac-labelled vs. {sup 213}Bi-labelled tumour-homing peptides in a preclinical mouse model of peritoneal carcinomatosis

    Energy Technology Data Exchange (ETDEWEB)

    Essler, Markus; Gaertner, Florian C.; Blechert, Birgit; Senekowitsch-Schmidtke, Reingard; Seidl, Christof [Technische Universitaet Muenchen, Department of Nuclear Medicine, Munich (Germany); Neff, Frauke [Helmholtz Zentrum Muenchen, Institute of Pathology, Neuherberg (Germany); Bruchertseifer, Frank; Morgenstern, Alfred [Institute for Transuranium Elements, European Commission, Joint Research Centre, Karlsruhe (Germany)

    2012-04-15

    Targeted delivery of alpha-particle-emitting radionuclides is a promising novel option in cancer therapy. We generated stable conjugates of the vascular tumour-homing peptide F3 both with {sup 225}Ac and {sup 213}Bi that specifically bind to nucleolin on the surface of proliferating tumour cells. The aim of our study was to determine the therapeutic efficacy of {sup 225}Ac-DOTA-F3 in comparison with that of {sup 213}Bi-DTPA-F3. ID{sub 50} values of {sup 213}Bi-DTPA-F3 and {sup 225}Ac-DOTA-F3 were determined via clonogenic assays. The therapeutic efficacy of both constructs was assayed by repeated treatment of mice bearing intraperitoneal MDA-MB-435 xenograft tumours. Therapy was monitored by bioluminescence imaging. Nephrotoxic effects were analysed by histology. ID{sub 50} values of {sup 213}Bi-DTPA-F3 and {sup 225}Ac-DOTA-F3 were 53 kBq/ml and 67 Bq/ml, respectively. The median survival of control mice treated with phosphate-buffered saline was 60 days after intraperitoneal inoculation of 1 x 10{sup 7} MDA-MB-435 cells. Therapy with 6 x 1.85 kBq of {sup 225}Ac-DOTA-F3 or 6 x 1.85 MBq of {sup 213}Bi-DTPA-F3 prolonged median survival to 95 days and 97 days, respectively. While F3 labelled with short-lived {sup 213}Bi (t{sub 1/2} 46 min) reduced the tumour mass at early time-points up to 30 days after treatment, the antitumour effect of {sup 225}Ac-DOTA-F3 (t{sub 1/2} 10 days) increased at later time-points. The difference in the fraction of necrotic cells after treatment with {sup 225}Ac-DOTA-F3 (43%) and with {sup 213}Bi-DTPA-F3 (36%) was not significant. Though histological analysis of kidney samples revealed acute tubular necrosis and tubular oedema in 10-30% of animals after treatment with {sup 225}Ac-DOTA-F3 or {sup 213}Bi-DTPA-F3, protein casts were negligible (2%), indicating only minor damage to the kidney. Therapy with both {sup 225}Ac-DOTA-F3 and {sup 213}Bi-DTPA-F3 increased survival of mice with peritoneal carcinomatosis. Mild renal toxicity of both

  12. Influence of tumour size on the efficacy of targeted alpha therapy with (213)Bi-[DOTA(0),Tyr(3)]-octreotate.

    Science.gov (United States)

    Chan, Ho Sze; Konijnenberg, Mark W; de Blois, Erik; Koelewijn, Stuart; Baum, Richard P; Morgenstern, Alfred; Bruchertseifer, Frank; Breeman, Wouter A; de Jong, Marion

    2016-12-01

    Targeted alpha therapy has been postulated to have great potential for the treatment of small clusters of tumour cells as well as small metastases. (213)Bismuth, an α-emitter with a half-life of 46 min, has shown to be effective in preclinical as well as in clinical applications. In this study, we evaluated whether (213)Bi-[DOTA(0), Tyr(3)]-octreotate ((213)Bi-DOTATATE), a (213)Bi-labelled somatostatin analogue with high affinity for somatostatin receptor subtype 2 (SSTR2), is suitable for the treatment of larger neuroendocrine tumours overexpressing SSTR2 in comparison to its effectiveness for smaller tumours. We performed a preclinical targeted radionuclide therapy study with (213)Bi-DOTATATE in animals bearing tumours of different sizes (50 and 200 mm(3)) using two tumour models: H69 (human small cell lung carcinoma) and CA20948 (rat pancreatic tumour). Pharmacokinetics was determined for calculation of dosimetry in organs and tumours. H69- or CA20948-xenografted mice with tumour volumes of approximately 120 mm(3) were euthanized at 10, 30, 60 and 120 min post injection of a single dose of (213)Bi-DOTATATE (1.5-4.8 MBq). To investigate the therapeutic efficacy of (213)Bi-DOTATATE, xenografted H69 and CA20948 tumour-bearing mice with tumour sizes of 50 and 200 mm(3) were administered daily with a therapeutic dose of (213)Bi-DOTATATE (0.3 nmol, 2-4 MBq) for three consecutive days. The animals were followed for 90 days after treatment. At day 90, mice were injected with 25 MBq (99m)Tc-DMSA and imaged by SPECT/CT to investigate possible renal dysfunction due to (213)Bi-DOTATATE treatment. Higher tumour uptakes were found in CA20948 tumour-bearing animals compared to those in H69 tumour-bearing mice with the highest tumour uptake of 19.6 ± 6.6 %IA/g in CA20948 tumour-bearing animals, while for H69 tumour-bearing mice, the highest tumour uptake was found to be 9.8 ± 2.4 %IA/g. Nevertheless, as the anti-tumour effect was more pronounced in H69

  13. 177Lu-immunotherapy of experimental peritoneal carcinomatosis shows comparable effectiveness to 213Bi-immunotherapy, but causes toxicity not observed with 213Bi

    International Nuclear Information System (INIS)

    Seidl, Christof; Zoeckler, Christine; Beck, Roswitha; Senekowitsch-Schmidtke, Reingard; Quintanilla-Martinez, Leticia; Bruchertseifer, Frank

    2011-01-01

    213 Bi-d9MAb-immunoconjugates targeting gastric cancer cells have effectively cured peritoneal carcinomatosis in a nude mouse model following intraperitoneal injection. Because the β-emitter 177 Lu has proven to be beneficial in targeted therapy, 177 Lu-d9MAb was investigated in this study in order to compare its therapeutic efficacy and toxicity with those of 213 Bi-d9MAb. Nude mice were inoculated intraperitoneally with HSC45-M2 gastric cancer cells expressing d9-E-cadherin and were treated intraperitoneally 1 or 8 days later with different activities of specific 177 Lu-d9MAb immunoconjugates targeting d9-E-cadherin or with nonspecific 177 Lu-d8MAb. Therapeutic efficacy was evaluated by monitoring survival for up to 250 days. For evaluation of toxicity, both biodistribution of 177 Lu-d9MAb and blood cell counts were determined at different time points and organs were examined histopathologically. Treatment with 177 Lu-immunoconjugates (1.85, 7.4, 14.8 MBq) significantly prolonged survival. As expected, treatment on day 1 after tumour cell inoculation was more effective than treatment on day 8, and specific 177 Lu-d9MAb conjugates were superior to nonspecific 177 Lu-d8MAb. Treatment with 7.4 MBq of 177 Lu-d9MAb was most successful, with 90% of the animals surviving longer than 250 days. However, treatment with therapeutically effective activities of 177 Lu-d9MAb was not free of toxic side effects. In some animals lymphoblastic lymphoma, proliferative glomerulonephritis and hepatocarcinoma were seen but were not observed after treatment with 213 Bi-d9MAb at comparable therapeutic efficacy. The therapeutic efficacy of 177 Lu-d9MAb conjugates in peritoneal carcinomatosis is impaired by toxic side effects. Because previous therapy with 213 Bi-d9MAb revealed comparable therapeutic efficacy without toxicity it should be preferred for the treatment of peritoneal carcinomatosis. (orig.)

  14. Cancer therapy with alpha-emitters labeled peptides.

    Science.gov (United States)

    Dadachova, Ekaterina

    2010-05-01

    Actively targeted alpha-particles offer specific tumor cell killing action with less collateral damage to surrounding normal tissues than beta-emitters. During the last decade, radiolabeled peptides that bind to different receptors on the tumors have been investigated as potential therapeutic agents both in the preclinical and clinical settings. Advantages of radiolabeled peptides over antibodies include relatively straightforward chemical synthesis, versatility, easier radiolabeling, rapid clearance from the circulation, faster penetration and more uniform distribution into tissues, and less immunogenicity. Rapid internalization of the radiolabeled peptides with equally rapid re-expression of the cell surface target is a highly desirable property that enhances the total delivery of these radionuclides into malignant sites. Peptides, such as octreotide, alpha-melanocyte-stimulating hormone analogues, arginine-glycine-aspartic acid-containing peptides, bombesin derivatives, and others may all be feasible for use with alpha-emitters. The on-going preclinical work has primarily concentrated on octreotide and octreotate analogues labeled with Bismuth-213 and Astatine-211. In addition, alpha-melanocyte-stimulating hormone analogue has been labeled with Lead-212/Bismuth-212 in vivo generator and demonstrated the encouraging therapeutic efficacy in treatment of experimental melanoma. Obstacles that continue to obstruct widespread acceptance of alpha-emitter-labeled peptides are primarily the supply of these radionuclides and concerns about potential kidney toxicity. New sources and methods for production of these medically valuable radionuclides and better understanding of mechanisms related to the peptide renal uptake and clearance should speed up the introduction of alpha-emitter-labeled peptides into the clinic. Copyright 2010 Elsevier Inc. All rights reserved.

  15. Direct {sup 99m}Tc labeling of Herceptin (trastuzumab) by {sup 99m}Tc(I) tricarbonyl ion

    Energy Technology Data Exchange (ETDEWEB)

    Chen, W.-J.; Yen, C.-L.; Lo, S.-T.; Chen, K.-T. [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Lo, J.-M. [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan (China)], E-mail: jmlo@mx.nthu.edu.tw

    2008-03-15

    By simply incubating Herceptin (trastuzumab) with [{sup 99m}Tc(CO){sub 3}(OH{sub 2}){sub 3}]{sup +} ion in saline, a significant yield of {sup 99m}Tc-labeled trastuzumab was found to be achievable. The effective labeling may be based on that trastuzumab is inherent with endogenous histidine group to which {sup 99m}Tc(I) tricarbonyl ion can be strongly bound. For practical {sup 99m}Tc labeling processing, trastuzumab was purified beforehand from the commercial product, Herceptin (Genentech) via size exclusion chromatography to remove the excipient, {alpha}-histidine and a high-labeled yield could be obtained by incubating the purified trastuzumab with [{sup 99m}Tc(CO){sub 3}(OH{sub 2}){sub 3}]{sup +}. Retention of bioactivity of the {sup 99m}Tc(I)-labeled trastuzumab was validated using a cell binding test.

  16. Production of alpha emitters for therapy

    International Nuclear Information System (INIS)

    Vucina, J.; Orlic, M.; Lukic, D.

    2006-01-01

    The basis for the introduction of alpha emitters into nuclear medical practice are their radiobiological properties. High LET values and short ranges in biological tissues are advantageous in comparison with nowadays most often used beta emitters, primarily 90 Y and 131 I. Given are the most important criteria for the introduction of a given radionuclide in the routine use. Shown are the procedures for the production of the most important alpha emitters 211 At, 212 Bi and 213 Bi. (author)

  17. Studies of α-spectra in 221Fr, 217At, 213Bi and 213Po decays

    International Nuclear Information System (INIS)

    Chumin, V.G.; Fominykh, V.I.; Furyaev, T.A.; Gromov, K.Ya.; Jabber, J.K.; Kalyapkin, K.V.; Kudrya, S.A.; Tsupko-Sitnikov, V.V.

    1997-01-01

    The alpha-recoil phenomenon is used to gain data on the weak components of the α-spectra of the nuclides from the 225 Ac equilibrium chain. It is established that there is no experimental basis for introducing the 450 keV level of 213 Bi in the 217 At decay and the 868 keV level of 209 Tl in the 213 Bi decay. Excitation of the 759 keV level in the 217 At decay is confirmed. The intensities of the 221 Fr, 217 At and 213 Bi β - -decay are measured

  18. Enhanced efficacy of combined 213Bi-DTPA-F3 and paclitaxel therapy of peritoneal carcinomatosis is mediated by enhanced induction of apoptosis and G2/M phase arrest

    International Nuclear Information System (INIS)

    Vallon, Mario; Seidl, Christof; Blechert, Birgit; Li, Zhoulei; Gaertner, Florian C.; Senekowitsch-Schmidtke, Reingard; Essler, Markus; Gilbertz, Klaus-Peter; Baumgart, Anja; Aichler, Michaela; Feuchtinger, Annette; Walch, Axel K.; Bruchertseifer, Frank; Morgenstern, Alfred

    2012-01-01

    Targeted therapy with α-particle emitting radionuclides is a promising new option in cancer therapy. Stable conjugates of the vascular tumour-homing peptide F3 with the α-emitter 213 Bi specifically target tumour cells. The aim of our study was to determine efficacy of combined 213 Bi-diethylenetriaminepentaacetic acid (DTPA)-F3 and paclitaxel treatment compared to treatment with either 213 Bi-DTPA-F3 or paclitaxel both in vitro and in vivo. Cytotoxicity of treatment with 213 Bi-DTPA-F3 and paclitaxel, alone or in combination, was assayed towards OVCAR-3 cells using the alamarBlue assay, the clonogenic assay and flow cytometric analyses of the mode of cell death and cell cycle arrest. Therapeutic efficacy of the different treatment options was assayed after repeated treatment of mice bearing intraperitoneal OVCAR-3 xenograft tumours. Therapy monitoring was performed by bioluminescence imaging and histopathologic analysis. Treatment of OVCAR-3 cells in vitro with combined 213 Bi-DTPA-F3 and paclitaxel resulted in enhanced cytotoxicity, induction of apoptosis and G2/M phase arrest compared to treatment with either 213 Bi-DTPA-F3 or paclitaxel. Accordingly, i.p. xenograft OVCAR-3 tumours showed the best response following repeated (six times) combined therapy with 213 Bi-DTPA-F3 (1.85 MBq) and paclitaxel (120 μg) as demonstrated by bioluminescence imaging and histopathologic investigation of tumour spread on the mesentery of the small and large intestine. Moreover, mean survival of xenograft mice that received combined therapy with 213 Bi-DTPA-F3 and paclitaxel was significantly superior to mice treated with either 213 Bi-DTPA-F3 or paclitaxel alone. Combined treatment with 213 Bi-DTPA-F3 and paclitaxel significantly increased mean survival of mice with peritoneal carcinomatosis of ovarian origin, thus favouring future therapeutic application. (orig.)

  19. 177Lu labeling of Herceptin and preclinical validation as a new radiopharmaceutical for radioimmunotherapy of breast cancer

    International Nuclear Information System (INIS)

    Rasaneh, Samira; Rajabi, Hossein; Babaei, Mohammad Hossein; Daha, Fariba Johari

    2010-01-01

    Introduction: In the present study, Herceptin was labeled with lutetium-177 via DOTA, and the necessary preclinical quality control tests (in vitro and in vivo) were performed to evaluate its use as a radioimmunotherapy agent. Material and Methods: Herceptin was conjugated to DOTA as a chelator in three different conjugation buffers (ammonium acetate, carbonate and HEPES buffer); each of the resulting conjugates was compared with respect to in vitro characteristics such as number of chelates per antibody, incorporated activity, immunoreactivity and in vitro stability in PBS buffer and blood serum. The biodistribution study and gamma camera imaging were performed in mice bearing breast tumors. To assess the therapeutic effects of 177 Lu-Herceptin, cytotoxicity was investigated for 7 days in a SKBr3 breast cancer cell line. Results: Carbonate buffer was the best conjugation buffer (number of chelates per antibody: 6; incorporated activity: 81%; immunoreactivity: 87%; buffer stability: 86%; serum stability: 81%, after 4 days). The efficient tumor uptake observed in the biodistribution studies was consistent with the gamma camera image results. At a concentration of 4 μg ml -1 , 177 Lu-Herceptin (surviving cells: 5±0.6% of the total cells) of the total cells corresponded to an approximately eightfold increase in cytotoxicity in comparison to unmodified Herceptin (surviving cells: 43±3.9%). Conclusion: The new complex described herein could be considered for further evaluation in animals and potentially in humans as a radiopharmaceutical for use in the radioimmunotherapy of breast cancer. These results may be important for patients who cannot tolerate the therapeutic dosage of Herceptin currently used because of heart problems.

  20. Enhanced efficacy of combined {sup 213}Bi-DTPA-F3 and paclitaxel therapy of peritoneal carcinomatosis is mediated by enhanced induction of apoptosis and G2/M phase arrest

    Energy Technology Data Exchange (ETDEWEB)

    Vallon, Mario; Seidl, Christof; Blechert, Birgit; Li, Zhoulei; Gaertner, Florian C.; Senekowitsch-Schmidtke, Reingard; Essler, Markus [Technische Universitaet Muenchen, Department of Nuclear Medicine, Munich (Germany); Gilbertz, Klaus-Peter [German Armed Forces, Institute of Radiobiology, Munich (Germany); Baumgart, Anja [Technische Universitaet Muenchen, III. Medical Department, Munich (Germany); Aichler, Michaela; Feuchtinger, Annette; Walch, Axel K. [Helmholtz Zentrum Muenchen, Institute of Pathology, Neuherberg (Germany); Bruchertseifer, Frank; Morgenstern, Alfred [Institute for Transuranium Elements, European Commission, Joint Research Centre, Karlsruhe (Germany)

    2012-12-15

    Targeted therapy with {alpha}-particle emitting radionuclides is a promising new option in cancer therapy. Stable conjugates of the vascular tumour-homing peptide F3 with the {alpha}-emitter {sup 213}Bi specifically target tumour cells. The aim of our study was to determine efficacy of combined {sup 213}Bi-diethylenetriaminepentaacetic acid (DTPA)-F3 and paclitaxel treatment compared to treatment with either {sup 213}Bi-DTPA-F3 or paclitaxel both in vitro and in vivo. Cytotoxicity of treatment with {sup 213}Bi-DTPA-F3 and paclitaxel, alone or in combination, was assayed towards OVCAR-3 cells using the alamarBlue assay, the clonogenic assay and flow cytometric analyses of the mode of cell death and cell cycle arrest. Therapeutic efficacy of the different treatment options was assayed after repeated treatment of mice bearing intraperitoneal OVCAR-3 xenograft tumours. Therapy monitoring was performed by bioluminescence imaging and histopathologic analysis. Treatment of OVCAR-3 cells in vitro with combined {sup 213}Bi-DTPA-F3 and paclitaxel resulted in enhanced cytotoxicity, induction of apoptosis and G2/M phase arrest compared to treatment with either {sup 213}Bi-DTPA-F3 or paclitaxel. Accordingly, i.p. xenograft OVCAR-3 tumours showed the best response following repeated (six times) combined therapy with {sup 213}Bi-DTPA-F3 (1.85 MBq) and paclitaxel (120 {mu}g) as demonstrated by bioluminescence imaging and histopathologic investigation of tumour spread on the mesentery of the small and large intestine. Moreover, mean survival of xenograft mice that received combined therapy with {sup 213}Bi-DTPA-F3 and paclitaxel was significantly superior to mice treated with either {sup 213}Bi-DTPA-F3 or paclitaxel alone. Combined treatment with {sup 213}Bi-DTPA-F3 and paclitaxel significantly increased mean survival of mice with peritoneal carcinomatosis of ovarian origin, thus favouring future therapeutic application. (orig.)

  1. Therapeutic Efficacy of Alpha-RIT Using a (213)Bi-Anti-hCD138 Antibody in a Mouse Model of Ovarian Peritoneal Carcinomatosis.

    Science.gov (United States)

    Derrien, Aurélie; Gouard, Sébastien; Maurel, Catherine; Gaugler, Marie-Hélène; Bruchertseifer, Frank; Morgenstern, Alfred; Faivre-Chauvet, Alain; Classe, Jean-Marc; Chérel, Michel

    2015-01-01

    Ovarian peritoneal carcinomatosis is a pathology for which effective cures are currently lacking. New research protocols seek to eradicate residual micrometastases following cytoreductive surgery by using hyperthermic intraperitoneal chemotherapy (HIPEC) or radioimmunotherapy (RIT). This study aims to first develop alpha-RIT using an anti-CD138 mAb radiolabeled with an alpha-emitter, bismuth-213 ((213)Bi-B-B4) and HIPEC in a nude mouse model and second to compare and combine these techniques. A murine model of postoperative ovarian peritoneal carcinomatosis was established. A pilot group of six mice received an intraperitoneal injection of luciferase-tagged SHIN-3 cells and bioluminescence was measured every day. Cytoreductive surgery was performed at day 14 (n = 4) and 29 (n = 2). Because the residual bioluminescence signal measured after surgery was equivalent to that obtained 3 days after the graft, HIPEC or alpha-RIT treatments were applied 3 days after the graft. Ten mice were treated by HIPEC with cisplatine (37.5 mg/mL), 11 with 7.4 MBq of (213)Bi-B-B4, seven with 11.1 MBq of (213)Bi-B-B4, and 10 mice were treated with the combined therapy (HIPEC + 7.4 MBq of (213)Bi-B-B4). Eleven mice received no treatment. Bioluminescence imaging and survival were assessed. Alpha-RIT 7.4 MBq and 11.1 MBq significantly improved survival (p = 0.0303 and p = 0.0070, respectively), whereas HIPEC and HIPEC + alpha-RIT treatments did not significantly ameliorate survival as compared to the control group. Survival was significantly increased by alpha-RIT treatment in mice with peritoneal carcinomatosis of ovarian origin; however, HIPEC alone or in combination with alpha-RIT had no significant effect.

  2. Actinium-225 and Bismuth-213 Alpha Particle Immunotherapy of Cancer

    International Nuclear Information System (INIS)

    Scheinberg, D.

    2013-01-01

    Nuclides with appropriate half-lives and emission characteristics that would be potent enough to kill neoplastic cells in the small quantities that reach targets in vivo, include the high linear energy transfer (LET) alpha emitters such as Actinium-225 and Bi-213. We developed methods for the attachment of radiometals via bifunctional chelates to monoclonal antibodies (mAb) without loss of immunoreactivity. We developed alphaemitting Bi-213 lintuzumab constructs, characterized and qualified them in preclinical models, and took them into human clinical trials in patients with AML. Safety, anti-leukemic activity, and complete responses (CR’s) have been demonstrated through phase 2 trilas. Bi-213 is produced in a portable small generator device based on Ac- 225 in the hospital nuclear medicine lab. The isotope is then purified, attached to the antibody, and the product is qualified and processed. Despite this success, the major obstacle to the widespread use of these drugs remains the short 213 Bi half-life (46 minutes), which poses a large logistical hurdle before injection and limits its delivery to only the most accessible cancer cells after injection

  3. In vitro evaluation of 213Bi-rituximab versus external gamma irradiation for the treatment of B-CLL patients: relative biological efficacy with respect to apoptosis induction and chromosomal damage

    International Nuclear Information System (INIS)

    Vandenbulcke, Katia; Lahorte, Christophe; Slegers, Guido; De Vos, Filip; Dierckx, Rudi A.; Offner, Fritz; Philippe, Jan; Apostolidis, Christos; Molinet, Roger; Nikula, Tuomo K.; Bacher, Klaus; De Gelder, Virginie; Vral, Anne; Thierens, Hubert

    2003-01-01

    External source radiotherapy and beta radioimmunotherapy (RIT) are effective treatments for lymphoid malignancies. The development of RIT with alpha emitters is attractive because of the high linear energy transfer (LET) and short path length, allowing higher tumour cell kill and lower toxicity to healthy tissues. We assessed the relative biological efficacy (RBE) of alpha RIT (in vitro) compared to external gamma irradiation with respect to induction of apoptosis in B chronic lymphocytic leukaemia (B-CLL) and induction of chromosomal damage in healthy donor B and T lymphocytes. The latter was measured by a micronucleus assay. 213 Bi was eluted from a 225 Ac generator and conjugated to CD20 antibody (rituximab) with CHX-A''-DTPA as a chelator. B-CLL cells from five patients were cultured for 24 h in RPMI/10% FCS while exposed to 213 Bi conjugated to CD20 antibody or after external 60 Co gamma irradiation. Binding assays were performed in samples of all patients to calculate the total absorbed dose. Apoptosis was scored by flow cytometric analyses of the cells stained with annexin V-FITC and 7-AAD. Apoptosis was expressed as % excess over spontaneous apoptosis in control. Full dose range experiments demonstrated 213 Bi-conjugated CD20 antibody to be more effective than equivalent doses of external gamma irradiation, but showed that similar plateau values were reached at 10 Gy. The RBE for induction of apoptosis in B-CLL was 2 between 1.5 and 7 Gy. The micronucleus yield in lymphocytes of healthy volunteers was measured to assess the late toxicity caused by induction of chromosomal instability. While gamma radiation induced a steady increase in micronucleus yields in B and T cells, the damage induced by 213 Bi was more dramatic, with RBE ranging from 5 to 2 between 0.1 Gy and 2 Gy respectively. In contrast to gamma irradiation, 213 Bi inhibited mitogen-stimulated mitosis almost completely at 2 Gy. In conclusion, high-LET targeted alpha particle exposure killed B

  4. Evaluation of preclinical single and multiple dose toxicity and efficacy of 213 Bi-labeled plasminogen activator inhibitor 2 for breast and prostate cancer

    International Nuclear Information System (INIS)

    Rizvi, S.; Li, Y.; Allen, B.; Littlejohn, T.; Ranson, M.; Links, M.; Irving, D.; Andrews, J.

    2003-01-01

    The aim of the study was to evaluate the single and multiple dose toxicity (maximum tolerated dose or MTD) regimes for 213 Bi-labeled PAI2. Dose range of 2-8 mCi/kg was used for the single dose toxicity studies. It was found that end point (20% weight loss and/or distressed behaviour) was not reached for the highest dose either with single or multiple dose injections. For multiple dose toxicity studies, the dose levels ranged between 0.4 - 2 mCi/kg, and were administered daily for 5 days. The highest level tested (2mCi/kg/day x 5) was the maximum tolerated dose as 3/6 mice succumbed to the endpoints. However, histological examination of major organs showed no adverse morphological changes. From these toxicity studies, we concluded that either a dose of 1.6mCi/kg of 213 Bi-PAI2 per day for 5 days or a single injection of 8 mCi/kg can be administered without reaching the endpoints. These dose levels were used for efficacy trials. The efficacy studies were conducted to examine if the 1.6mCi/kgday x 5 multiple dose schedule (sub-maximum tolerated dose) showed efficacy against established and early stage human breast and prostate tumours in mice. Statistical analyses of the data indicate a significant tumour growth rate delay and increased time to reach tumour size endpoint for alpha-PAI2 treatment compared to control tumours, in both pre-tumour stage and established tumour models

  5. Selective T-cell Ablation with Bismuth-213 Labeled Anti-TCR Alpha Beta as Nonmyeloablative Conditionaing for Allogeneic Canine Marrow Transplantion

    Energy Technology Data Exchange (ETDEWEB)

    Bethge, W. A.; Wilbur, D. Scott; Storb, R.; Hamlin, Donald K.; Santos, E. B.; Brechbiel, M. W.; Fisher, Darrell R.; Sandmaier, B. M.

    2003-06-15

    Two major immunological barriers, the host versus graft (HVG) and the graft versus host (GVH) reaction, must be overcome for successful allogeneic hematopoietic stem cell transplantation. T-cells are involved in these barriers in the major histocompatibility complex-identical settings. We hypothesized that selective ablation of T-cells using radioimmunotherapy, together with postgrafting immunosuppression, would ensure stable allogeneic engraftment. We developed a canine model of nonmyeloablative marrow transplantation in which host immune reactions are impaired by a single dose of 2 Gy total body irradiation (TBI), and where both GVH and residual HVG reactions are controlled by postgrafting immunosuppression with mycophenolate mofetil (MMF) and cyclosporine (CSP). We substituted the alpha-emitter bismuth-213 linked to a monoclonal antibody against TCR(alpha,beta)using the metal-binding chelate CHX-A”-DTPA, for 2 Gy TBI. Biodistribution studies using a gamma-emitting indium-111-labeled anti-TCR mAb showed uptake primarily in blood, marrow, lymph nodes, spleen and liver. In a dosimetry study, 4 dogs were treated with 0.13-0.46 mg/kg TCR mAb labeled with 3.7-5.6 mCi/kg (137-207 MBq/kg) Bi-213. The treatment was administered in 6 injections on days -3 and -2 followed by transplantion of dog leukocyte antigen-identical marrow on day 0 and postgrafting immunosuppression with MMF and CSP. Therapy was well tolerated except for elevations of transaminases, which were transient in all but one dog. No other organ toxicities or signs of graft-versus-host-disease were noted. The dogs had prompt allogeneic hematopoietic engraftment and achieved stable mixed donor-host hematopoietic chimerism with donor contributions ranging from 5-55 % with >30 weeks follow up.

  6. Selective T-cell Ablation with Bismuth-213 Labeled Anti-TCR Alpha Beta as Nonmyeloablative Conditioning for Allogeneic Canine Marrow Transplantion

    International Nuclear Information System (INIS)

    Bethge, W. A.; Wilbur, D. Scott; Storb, R.; Hamlin, Donald K.; Santos, E. B.; Brechbiel, M. W.; Fisher, Darrell R.; Sandmaier, B. M.

    2003-01-01

    Two major immunological barriers, the host versus graft (HVG) and the graft versus host (GVH) reaction, must be overcome for successful allogeneic hematopoietic stem cell transplantation. T-cells are involved in these barriers in the major histocompatibility complex-identical settings. We hypothesized that selective ablation of T-cells using radioimmunotherapy, together with postgrafting immunosuppression, would ensure stable allogeneic engraftment. We developed a canine model of nonmyeloablative marrow transplantation in which host immune reactions are impaired by a single dose of 2 Gy total body irradiation (TBI), and where both GVH and residual HVG reactions are controlled by postgrafting immunosuppression with mycophenolate mofetil (MMF) and cyclosporine (CSP). We substituted the alpha-emitter bismuth-213 linked to a monoclonal antibody against TCR(alpha,beta)using the metal-binding chelate CHX-A-DTPA, for 2 Gy TBI. Biodistribution studies using a gamma-emitting indium-111-labeled anti-TCR mAb showed uptake primarily in blood, marrow, lymph nodes, spleen and liver. In a dosimetry study, 4 dogs were treated with 0.13-0.46 mg/kg TCR mAb labeled with 3.7-5.6 mCi/kg (137-207 MBq/kg) Bi-213. The treatment was administered in 6 injections on days -3 and -2 followed by transplantion of dog leukocyte antigen-identical marrow on day 0 and postgrafting immunosuppression with MMF and CSP. Therapy was well tolerated except for elevations of transaminases, which were transient in all but one dog. No other organ toxicities or signs of graft-versus-host-disease were noted. The dogs had prompt allogeneic hematopoietic engraftment and achieved stable mixed donor-host hematopoietic chimerism with donor contributions ranging from 5-55 % with >30 weeks follow up

  7. Renal uptake of bismuth-213 and its contribution to kidney radiation dose following administration of actinium-225-labeled antibody

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, J; O' Donoghue, J A; Humm, J L [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Jaggi, J S [Bristol-Myers Squibb, Plainsboro, NJ (United States); Ruan, S; Larson, S M [Nuclear Medicine Service Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); McDevitt, M; Scheinberg, D A, E-mail: schwarj1@mskcc.org [Molecular Pharmacology and Chemistry, Sloan-Kettering Institute, 1275 York Avenue, New York, NY 10065 (United States)

    2011-02-07

    Clinical therapeutic studies using {sup 225}Ac-labeled antibodies have begun. Of major concern is renal toxicity that may result from the three alpha-emitting progeny generated following the decay of {sup 225}Ac. The purpose of this study was to determine the amount of {sup 225}Ac and non-equilibrium progeny in the mouse kidney after the injection of {sup 225}Ac-huM195 antibody and examine the dosimetric consequences. Groups of mice were sacrificed at 24, 96 and 144 h after injection with {sup 225}Ac-huM195 antibody and kidneys excised. One kidney was used for gamma ray spectroscopic measurements by a high-purity germanium (HPGe) detector. The second kidney was used to generate frozen tissue sections which were examined by digital autoradiography (DAR). Two measurements were performed on each kidney specimen: (1) immediately post-resection and (2) after sufficient time for any non-equilibrium excess {sup 213}Bi to decay completely. Comparison of these measurements enabled estimation of the amount of excess {sup 213}Bi reaching the kidney ({gamma}-ray spectroscopy) and its sub-regional distribution (DAR). The average absorbed dose to whole kidney, determined by spectroscopy, was 0.77 (SD 0.21) Gy kBq{sup -1}, of which 0.46 (SD 0.16) Gy kBq{sup -1} (i.e. 60%) was due to non-equilibrium excess {sup 213}Bi. The relative contributions to renal cortex and medulla were determined by DAR. The estimated dose to the cortex from non-equilibrium excess {sup 213}Bi (0.31 (SD 0.11) Gy kBq{sup -1}) represented {approx}46% of the total. For the medulla the dose contribution from excess {sup 213}Bi (0.81 (SD 0.28) Gy kBq{sup -1}) was {approx}80% of the total. Based on these estimates, for human patients we project a kidney-absorbed dose of 0.28 Gy MBq{sup -1} following administration of {sup 225}Ac-huM195 with non-equilibrium excess {sup 213}Bi responsible for approximately 60% of the total. Methods to reduce renal accumulation of radioactive progeny appear to be necessary for the

  8. In vitro evaluation of {sup 213}Bi-rituximab versus external gamma irradiation for the treatment of B-CLL patients: relative biological efficacy with respect to apoptosis induction and chromosomal damage

    Energy Technology Data Exchange (ETDEWEB)

    Vandenbulcke, Katia; Lahorte, Christophe; Slegers, Guido [Department of Radiopharmacy, Faculty of Pharmaceutical Sciences, Ghent University, Harelbekestraat 72, 9000, Gent (Belgium); De Vos, Filip; Dierckx, Rudi A. [Division of Nuclear Medicine, Ghent University Hospital (Belgium); Offner, Fritz [Department of Hematology, Ghent University Hospital (Belgium); Philippe, Jan [Department of Clinical Chemistry, Ghent University Hospital (Belgium); Apostolidis, Christos; Molinet, Roger; Nikula, Tuomo K. [European Commission, Joint Research Centre, Institute for Transuranium Elements, Karlsruhe (Germany); Bacher, Klaus; De Gelder, Virginie; Vral, Anne; Thierens, Hubert [Department of Anatomy, Embryology, Histology and Medical Physics, Ghent University (Belgium)

    2003-10-01

    External source radiotherapy and beta radioimmunotherapy (RIT) are effective treatments for lymphoid malignancies. The development of RIT with alpha emitters is attractive because of the high linear energy transfer (LET) and short path length, allowing higher tumour cell kill and lower toxicity to healthy tissues. We assessed the relative biological efficacy (RBE) of alpha RIT (in vitro) compared to external gamma irradiation with respect to induction of apoptosis in B chronic lymphocytic leukaemia (B-CLL) and induction of chromosomal damage in healthy donor B and T lymphocytes. The latter was measured by a micronucleus assay. {sup 213}Bi was eluted from a {sup 225}Ac generator and conjugated to CD20 antibody (rituximab) with CHX-A''-DTPA as a chelator. B-CLL cells from five patients were cultured for 24 h in RPMI/10% FCS while exposed to {sup 213}Bi conjugated to CD20 antibody or after external {sup 60}Co gamma irradiation. Binding assays were performed in samples of all patients to calculate the total absorbed dose. Apoptosis was scored by flow cytometric analyses of the cells stained with annexin V-FITC and 7-AAD. Apoptosis was expressed as % excess over spontaneous apoptosis in control. Full dose range experiments demonstrated {sup 213}Bi-conjugated CD20 antibody to be more effective than equivalent doses of external gamma irradiation, but showed that similar plateau values were reached at 10 Gy. The RBE for induction of apoptosis in B-CLL was 2 between 1.5 and 7 Gy. The micronucleus yield in lymphocytes of healthy volunteers was measured to assess the late toxicity caused by induction of chromosomal instability. While gamma radiation induced a steady increase in micronucleus yields in B and T cells, the damage induced by {sup 213}Bi was more dramatic, with RBE ranging from 5 to 2 between 0.1 Gy and 2 Gy respectively. In contrast to gamma irradiation, {sup 213}Bi inhibited mitogen-stimulated mitosis almost completely at 2 Gy. In conclusion, high

  9. Targeted alpha therapy of mCRPC. Dosimetry estimate of {sup 213}bismuth-PSMA-617

    Energy Technology Data Exchange (ETDEWEB)

    Kratochwil, Clemens; Afshar-Oromieh, Ali; Rathke, Hendrik; Giesel, Frederik L. [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); Schmidt, Karl [ABX-CRO, Dresden (Germany); Bruchertseifer, Frank; Morgenstern, Alfred [European Commission - Joint Research Centre, Directorate for Nuclear Safety and Security, Karlsruhe (Germany); Haberkorn, Uwe [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); German Cancer Research Center (DKFZ), Cooperation Unit Nuclear Medicine, Heidelberg (Germany)

    2018-01-15

    PSMA-617 is a small molecule targeting the prostate-specific membrane antigen (PSMA). In this work, we estimate the radiation dosimetry for this ligand labeled with the alpha-emitter {sup 213}Bi. Three patients with metastatic prostate cancer underwent PET scans 0.1 h, 1 h, 2 h, 3 h, 4 h and 5 h after injection of {sup 68}Ga-PSMA-617. Source organs were kidneys, liver, spleen, salivary glands, bladder, red marrow and representative tumor lesions. The imaging nuclide {sup 68}Ga was extrapolated to the half-life of {sup 213}Bi. The residence times of {sup 213}Bi were forwarded to the instable daughter nuclides. OLINDA was used for dosimetry calculation. Results are discussed in comparison to literature data for {sup 225}Ac-PSMA-617. Assuming a relative biological effectiveness of 5 for alpha radiation, the dosimetry estimate revealed equivalent doses of mean 8.1 Sv{sub RBE5}/GBq for salivary glands, 8.1 Sv{sub RBE5}/GBq for kidneys and 0.52 Sv{sub RBE5}/GBq for red marrow. Liver (1.2 Sv{sub RBE5}/GBq), spleen (1.4 Sv{sub RBE5}/GBq), bladder (0.28 Sv{sub RBE5}/GBq) and other organs (0.26 Sv{sub RBE5}/GBq) were not dose-limiting. The effective dose is 0.56 Sv{sub RBE5}/GBq. Tumor lesions were in the range 3.2-9.0 Sv{sub RBE5}/GBq (median 7.6 Sv{sub RBE5}/GBq). Kidneys would limit the cumulative treatment activity to 3.7 GBq; red marrow might limit the maximum single fraction to 2 GBq. Despite promising results, the therapeutic index was inferior compared to {sup 225}Ac-PSMA-617. Dosimetry of {sup 213}Bi-PSMA-617 is in a range traditionally considered reasonable for clinical application. Nevertheless, compared to {sup 225}Ac-PSMA-617, it suffers from higher perfusion-dependent off-target radiation and a longer biological half-life of PSMA-617 in dose-limiting organs than the physical half-life of {sup 213}Bi, rendering this nuclide as a second choice radiolabel for targeted alpha therapy of prostate cancer. (orig.)

  10. 188Re labeling and biodistribution of magnetic nanoparticles for the tumor targeting

    International Nuclear Information System (INIS)

    Li Guiping; Zhang Hui; Wang Yongxian; Zhang Chunfu

    2006-01-01

    Objective: To prepare 188 Re labeled monoclonal antibody (Herceptin)-coated magnetic nanoparticles for tumor targeting and to study its biodistribution in mice. Methods: Herceptin and histidine were covalently linked to the amine group upon silica-coated magnetic nanoparticles modified by N-[3-(trimethyoxysilyl)prowl]-ethylenediamine using glutaraldehyde method. The Herceptin-coated magnetic nanoparticles and Herceptin were radiolabeled with 188 Re by a direct labelling method, whereas the histidine-coated magnetic nanoparticles was radiolabeled with 188 Re using fac-[ 188 Re(CO) 3 (H 2 0) 3 ] + as a precursor. The labelling efficiency and immunoreactivity as well as labelling stability were determined. Also, the biodistribution of 188 Re-magnetic and 188 Re-Herceptin-magnetic nanoparticles were observed in mice. Results: Herceptin-coated magnetic nanoparticles was characterized by transmission electron microscope (TEM) with diameter about 60 nm, while histidine-coated magnetic nanoparticles about 30 nm. The labeling efficiency for 188 Re-Herceptin, 188 Re-magnetic nanoparticles and 188 Re-Herceptin-magnetic nanoparticles were all > 90% and had a better stability in vitro. The immunoreactivity of Herceptin linked to magnetic nanoparticles was still high. The biodistribution in mice was shown that 188 Re-magnetic nanoparticles and 188 Re-Herceptin- magnetic nanoparticles had higher radioactivity levels in blood. Magnetic nanoparticles with diameter of 30 or 60 nm had a long half-life in blood stream and were accumulated in liver. Conclusion: The efficiency and stability of labelling Herceptin-coated magnetic nanoparticles and labelling magnetic nanoparticles with 188 Re are suitable for in vivo study in tumor-beating nude mice models. (authors)

  11. Cell death triggered by alpha-emitting 213Bi-immunoconjugates in HSC45-M2 gastric cancer cells is different from apoptotic cell death

    International Nuclear Information System (INIS)

    Seidl, Christof; Schroeck, Hedwig; Seidenschwang, Sabine; Beck, Roswitha; Schwaiger, Markus; Senekowitsch-Schmidtke, Reingard; Schmid, Ernst; Abend, Michael; Becker, Karl-Friedrich; Apostolidis, Christos; Nikula, Tuomo K.; Kremmer, Elisabeth

    2005-01-01

    Radioimmunotherapy with α-particle-emitting nuclides, such as 213 Bi, is a promising concept for the elimination of small tumour nodules or single disseminated tumour cells. The aim of this study was to investigate cellular damage and the mode of cell death triggered by 213 Bi-immunoconjugates. Human gastric cancer cells (HSC45-M2) expressing d9-E-cadherin were incubated with different levels of activity of 213 Bi-d9MAb targeting d9-E-cadherin and 213 Bi-d8MAb, which does not bind to d9-E-cadherin. Micronucleated (M) cells, abnormal (A) cells and apoptotic (A) [(MAA)] cells were scored microscopically in the MAA assay following fluorescent staining of nuclei and cytoplasm. Chromosomal aberrations were analysed microscopically following Giemsa staining. The effect of z-VAD-fmk, known to inhibit apoptosis, on the prevention of cell death was investigated following treatment of HSC45-M2 cells with sorbitol as well as 213 Bi-d9MAb. Activation of caspase 3 after incubation of HSC45-M2 cells with both sorbitol and 213 Bi-d9MAb was analysed via Western blotting. Following incubation of HSC45-M2 human gastric cancer cells expressing d9-E-cadherin with 213 Bi-d9MAb the number of cells killed increased proportional to the applied activity concentration. Microscopically visible effects of α-irradiation of HSC45-M2 cells were formation of micronuclei and severe chromosomal aberrations. Preferential induction of these lesions with specific 213 Bi-d9MAb compared with unspecific 213 Bi-d8MAb (not targeting d9-E-cadherin) was not observed if the number of floating, i.e. unbound 213 Bi-immunoconjugates per cell exceeded 2 x 10 4 , most likely due to intense crossfire. In contrast to sorbitol-induced cell death, cell death triggered by 213 Bi-immunoconjugates was independent of caspase 3 activation and could not be inhibited by z-VAD-fmk, known to suppress the apoptotic pathway. 213 Bi-immunoconjugates seem to induce a mode of cell death different from apoptosis in HSC45-M2 cells

  12. Short-lived positron emitter labeled radiotracers - present status

    International Nuclear Information System (INIS)

    Fowler, J.S.; Wolf, A.P.

    1982-01-01

    The preparation of labelled compounds is important for the application of positron emission transaxial tomography (PETT) in biomedical sciences. This paper describes problems and progress in the synthesis of short-lived positron emitter ( 11 C, 18 F, 13 N) labelled tracers for PETT. Synthesis of labelled sugars, amino acids, and neurotransmitter receptors (pimozide and spiroperidol tagged with 11 C) is discussed in particular

  13. Cell death triggered by alpha-emitting {sup 213}Bi-immunoconjugates in HSC45-M2 gastric cancer cells is different from apoptotic cell death

    Energy Technology Data Exchange (ETDEWEB)

    Seidl, Christof; Schroeck, Hedwig; Seidenschwang, Sabine; Beck, Roswitha; Schwaiger, Markus; Senekowitsch-Schmidtke, Reingard [Technische Universitaet Muenchen, Department of Nuclear Medicine, Munich (Germany); Schmid, Ernst [National Research Center for Environment and Health, Institute of Radiation Biology, GSF, Neuherberg (Germany); Abend, Michael [German Armed Forces, Institute of Radiobiology, Munich (Germany); Becker, Karl-Friedrich [Technische Universitaet Muenchen, Institute of Pathology, Munich (Germany); National Research Center for Environment and Health, Institute of Pathology, GSF, Neuherberg (Germany); National Research Center for Environment and Health, Institute of Molecular Immunology, GSF, Munich (Germany); Apostolidis, Christos; Nikula, Tuomo K. [European Commission, Institute for Transuranium Elements, Karlsruhe (Germany); Kremmer, Elisabeth [National Research Center for Environment and Health, Institute of Molecular Immunology, GSF, Munich (Germany)

    2005-03-01

    Radioimmunotherapy with {alpha}-particle-emitting nuclides, such as{sup 213}Bi, is a promising concept for the elimination of small tumour nodules or single disseminated tumour cells. The aim of this study was to investigate cellular damage and the mode of cell death triggered by {sup 213}Bi-immunoconjugates. Human gastric cancer cells (HSC45-M2) expressing d9-E-cadherin were incubated with different levels of activity of {sup 213}Bi-d9MAb targeting d9-E-cadherin and {sup 213}Bi-d8MAb, which does not bind to d9-E-cadherin. Micronucleated (M) cells, abnormal (A) cells and apoptotic (A) [(MAA)] cells were scored microscopically in the MAA assay following fluorescent staining of nuclei and cytoplasm. Chromosomal aberrations were analysed microscopically following Giemsa staining. The effect of z-VAD-fmk, known to inhibit apoptosis, on the prevention of cell death was investigated following treatment of HSC45-M2 cells with sorbitol as well as {sup 213}Bi-d9MAb. Activation of caspase 3 after incubation of HSC45-M2 cells with both sorbitol and {sup 213}Bi-d9MAb was analysed via Western blotting. Following incubation of HSC45-M2 human gastric cancer cells expressing d9-E-cadherin with {sup 213}Bi-d9MAb the number of cells killed increased proportional to the applied activity concentration. Microscopically visible effects of {alpha}-irradiation of HSC45-M2 cells were formation of micronuclei and severe chromosomal aberrations. Preferential induction of these lesions with specific {sup 213}Bi-d9MAb compared with unspecific {sup 213}Bi-d8MAb (not targeting d9-E-cadherin) was not observed if the number of floating, i.e. unbound {sup 213}Bi-immunoconjugates per cell exceeded 2 x 10{sup 4}, most likely due to intense crossfire. In contrast to sorbitol-induced cell death, cell death triggered by {sup 213}Bi-immunoconjugates was independent of caspase 3 activation and could not be inhibited by z-VAD-fmk, known to suppress the apoptotic pathway. {sup 213}Bi-immunoconjugates seem

  14. Treatment of carcinoma in situ of the urinary bladder with an alpha-emitter immunoconjugate targeting the epidermal growth factor receptor: a pilot study.

    Science.gov (United States)

    Autenrieth, Michael E; Seidl, Christof; Bruchertseifer, Frank; Horn, Thomas; Kurtz, Florian; Feuerecker, Benedikt; D'Alessandria, Calogero; Pfob, Christian; Nekolla, Stephan; Apostolidis, Christos; Mirzadeh, Saed; Gschwend, Jürgen E; Schwaiger, Markus; Scheidhauer, Klemens; Morgenstern, Alfred

    2018-07-01

    Patients with carcinoma in situ (CIS) of the bladder refractory to bacillus Calmette-Guérin (BCG) treatment are usually treated with cystectomy. Therefore, new treatment options with preservation of the urinary bladder are needed. The objective of the study was to investigate the feasibility, safety and efficacy of a novel targeted alpha-emitter immunotherapy for CIS after BCG treatment failure. A pilot study was conducted in 12 patients (age range 64-86 years, ten men, two women) with biopsy-proven CIS of the bladder refractory to BCG treatment. The patients were treated intravesically with a single instillation (one patient was treated twice) of the alpha-emitter 213 Bi coupled to an anti-EGFR antibody (366-821 MBq). The primary aims of the study were to determine the feasibility of treatment with the 213 Bi-immunoconjugate and evaluation of adverse effects. Therapeutic efficacy was monitored by histological mapping of the urinary bladder 8 weeks after treatment and at different time points thereafter. The study proved that intravesical instillation of the 213 Bi-immunoconjugate targeting EGFR is feasible. No adverse effects were observed and all blood and urine parameters determined remained in their normal ranges. Therapeutic efficacy was considered satisfactory, in that three of the 12 patients showed no signs of CIS 44, 30 and 3 months after treatment. Intravesical instillation of 213 Bi-anti-EGFR monoclonal antibody was well tolerated and showed therapeutic efficacy. Repeated instillation and/or instillation of higher activities of the 213 Bi-immunoconjugate might lead to better therapeutic outcomes. A phase I clinical trial is planned.

  15. Positron emitter labeled enzyme inhibitors

    International Nuclear Information System (INIS)

    Fowler, J.S.; MacGregor, R.R.; Wolf, A.P.; Langstrom, B.

    1990-01-01

    This invention involves a new strategy for imagining and mapping enzyme activity in the living human and animal body using positron emitter-labeled suicide enzyme inactivators or inhibitors which become covalently bound to the enzyme as a result of enzymatic catalysis. Two such suicide inactivators for monoamine oxidase have been labeled with carbon-11 and used to map the enzyme subtypes in the living human and animal body using PET. By using positron emission tomography to image the distribution of radioactivity produced by the body penetrating radiation emitted by carbon-11, a map of functionally active monoamine oxidase activity is obtained. Clorgyline and L-deprenyl are suicide enzyme inhibitors and irreversibly inhibit monoamine oxidase. When these inhibitors are labeled with carbon-11 they provide selective probes for monoamine oxidase localization and reactivity in vivo using positron emission tomography

  16. Therapy of Patients with Malignant Glioma with Targeted A-Radionuclide Therapy Using 213Bi-DOTA-[Thi8, Met (Oo)11]-Substanz P

    International Nuclear Information System (INIS)

    Forrer, F.; Mueller-Brand, J.; Cordier, D.; Merlo, A.; Morgenstern, A.; Bruchertseifer, F.; Maecke, H.R.

    2009-01-01

    The prognosis of patients with malignant glioma is very poor. New therapy options are mandatory. Substance P is the main ligand of neurokinin type 1 (NK-1) receptors, which are consistently over-expressed in malignant gliomas and surrounding tumor vessels. Administration of 90 Y-DOTA-[Thi 8 , Met (O o ) 11 ]-Substanz P was shown to be feasible and safe. However, in critically located tumors, the mean tissue range of 5 mm of 90 Y may lead to unacceptable damage of adjacent, functional critical areas of the brain. We report a phase I study with locally administered 213 Bi labeled DOTA-[Thi 8 , Met (O o ) 11 ]-Substanz P in patients with malignant glioma. By using a direct, intratumoral injection, the problem of the short physical half life of Bismuth-213 can be circumvent. To date, 5 patients with malignant glioma (2 Grade IV, 1 Grade III and 2 grade II) without previous treatment were included. One to three catheter systems were placed stereotactically into the tumor. After a diagnostic injection with 111 In-DOTA-[Thi 8 , Met (O o ) 11 ]-Substanz P and subsequent dosimetry, totally 30 to 138 mCi of 213 Bi-DOTA-[Thi8, Met (O o ) 11 ]-Substanz P was injected intratumorally performing 3 to 4 applications over 2 days. SPECT/CT was used to assess the biodistribution. Follow up was performed clinically and with morphological imaging. Targeted radiopeptide therapy using 213 Bi-DOTA-[Thi 8 , Met (O o ) 11 ]-Substanz P was very well tolerated by all patients. No additional neurological deficit was observed. Repetitive imaging is suggestive of progressive radiation-induced necrosis, which was validated by subsequent resection of the tumors. Time to progression was found to be 11 and 14 months respectively in patients with grade IV glioma. No progression is found after 18 to 23 months in patients with grade II or III glioma. We conclude that targeted loco-regional radiotherapy using 213 Bi-DOTA-[Thi 8 , Met (O o ) 11 ]-Substanz P represents an innovative and effective

  17. Alpha particle emitters in medicine

    International Nuclear Information System (INIS)

    Fisher, D.R.

    1989-09-01

    Radiation-induced cancer of bone, liver and lung has been a prominent harmful side-effect of medical applications of alpha emitters. In recent years, however, the potential use of antibodies labeled with alpha emitting radionuclides against cancer has seemed promising because alpha particles are highly effective in cell killing. High dose rates at high LET, effectiveness under hypoxic conditions, and minimal expectancy of repair are additional advantages of alpha emitters over antibodies labeled with beta emitting radionuclides for cancer therapy. Cyclotron-produced astatine-211 ( 211 At) and natural bismuth-212 ( 212 Bi) have been proposed and are under extensive study in the United States and Europe. Radium-223 ( 223 Ra) also has favorable properties as a potential alpha emitting label, including a short-lived daughter chain with four alpha emissions. The radiation dosimetry of internal alpha emitters is complex due to nonuniformly distributed sources, short particle tracks, and high relative specific ionization. The variations in dose at the cellular level may be extreme. Alpha-particle radiation dosimetry, therefore, must involve analysis of statistical energy deposition probabilities for cellular level targets. It must also account fully for nonuniform distributions of sources in tissues, source-target geometries, and particle-track physics. 18 refs., 4 figs

  18. Improved safety and efficacy of 213Bi-DOTATATE-targeted alpha therapy of somatostatin receptor-expressing neuroendocrine tumors in mice pre-treated with L-lysine.

    Science.gov (United States)

    Chan, Ho Sze; Konijnenberg, Mark W; Daniels, Tamara; Nysus, Monique; Makvandi, Mehran; de Blois, Erik; Breeman, Wouter A; Atcher, Robert W; de Jong, Marion; Norenberg, Jeffrey P

    2016-12-01

    Targeted alpha therapy (TAT) offers advantages over current β-emitting conjugates for peptide receptor radionuclide therapy (PRRT) of neuroendocrine tumors. PRRT with 177 Lu-DOTATATE or 90 Y-DOTATOC has shown dose-limiting nephrotoxicity due to radiopeptide retention in the proximal tubules. Pharmacological protection can reduce renal uptake of radiopeptides, e.g., positively charged amino acids, to saturate in the proximal tubules, thereby enabling higher radioactivity to be safely administered. The aim of this preclinical study was to evaluate the therapeutic effect of 213 Bi-DOTATATE with and without renal protection using L-lysine in mice. Tumor uptake and kinetics as a function of injected mass of peptide (range 0.03-3 nmol) were investigated using 111 In-DOTATATE. These results allowed estimation of the mean radiation absorbed tumor dose for 213 Bi-DOTATATE. Pharmacokinetics and dosimetry of 213 Bi-DOTATATE was determined in mice, in combination with renal protection. A dose escalation study with 213 Bi-DOTATATE was performed to determine the maximum tolerated dose (MTD) with and without pre-administration of L-lysine as for renal protection. Neutrophil gelatinase-associated lipocalin (NGAL) served as renal biomarker to determine kidney injury. The maximum mean radiation absorbed tumor dose occurred at 0.03 nmol and the minimum at 3 nmol. Similar mean radiation absorbed tumor doses were determined for 0.1 and 0.3 nmol with a mean radiation absorbed dose of approximately 0.5 Gy/MBq 213 Bi-DOTATATE. The optimal mass of injected peptide was found to be 0.3 nmol. Tumor uptake was similar for 111 In-DOTATATE and 213 Bi-DOTATATE at 0.3 nmol peptide. Lysine reduced the renal uptake of 213 Bi-DOTATATE by 50% with no effect on the tumor uptake. The MTD was <13.0 ± 1.6 MBq in absence of L-lysine and 21.7 ± 1.9 MBq with L-lysine renal protection, both imparting an LD 50 mean renal radiation absorbed dose of 20 Gy. A correlation was found between the

  19. Targeted alpha therapy: Applications and current status

    International Nuclear Information System (INIS)

    Bruchertseifer, Frank

    2017-01-01

    Full text: The field of targeted alpha therapy has been developed rapidly in the last decade. Besides 223 Ra, 211 At and 212 Pb/ 212 Bi the alpha emitters 225 Ac and 213 Bi are promising therapeutic radionuclides for application in targeted alpha therapy of cancer and infectious diseases. The presentation will give a short overview about the current clinical treatments with alpha emitting radionuclides and will place an emphasis on the most promising clinical testing of peptides and antibodies labelled with 225 Ac and 213 Bi for treatment of metastatic castration-resistant prostate cancer patients with glioma and glioblastoma multiform, PSMA-positive tumor phenotype and bladder carcinoma in situ. (author)

  20. Targeted alpha therapy: Applications and current status

    Energy Technology Data Exchange (ETDEWEB)

    Bruchertseifer, Frank, E-mail: frank.bruchertseifer@ec.europa.eu [European Commission, Joint Research Centre, Karlsruhe (Germany)

    2017-07-01

    Full text: The field of targeted alpha therapy has been developed rapidly in the last decade. Besides {sup 223}Ra, {sup 211}At and {sup 212}Pb/{sup 212}Bi the alpha emitters {sup 225}Ac and {sup 213}Bi are promising therapeutic radionuclides for application in targeted alpha therapy of cancer and infectious diseases. The presentation will give a short overview about the current clinical treatments with alpha emitting radionuclides and will place an emphasis on the most promising clinical testing of peptides and antibodies labelled with {sup 225}Ac and {sup 213}Bi for treatment of metastatic castration-resistant prostate cancer patients with glioma and glioblastoma multiform, PSMA-positive tumor phenotype and bladder carcinoma in situ. (author)

  1. Kit for the preparation of 111In-labeled pertuzumab injection for imaging response of HER2-positive breast cancer to trastuzumab (Herceptin)

    International Nuclear Information System (INIS)

    Lam, Karen; Scollard, Deborah A.; Chan, Conrad; Levine, Mark N.; Reilly, Raymond M.

    2015-01-01

    We previously reported that 111 In-labeled pertuzumab imaged trastuzumab (Herceptin)-mediated changes in HER2 expression preclinically in breast cancer tumors. To advance 111 In-labeled pertuzumab to a Phase I/II clinical trial, a kit was designed for preparing this agent in a form suitable for human administration. Unit-dose kits containing pertuzumab modified with 2-(4-isothiocyanatobenzyl)-diethylenetriaminepentaacetic acid (BzDTPA) were prepared that labeled to high efficiency (>90%) with 111 In and met specifications for pharmaceutical quality. The kits were stable for 4 months and the final radiopharmaceutical was stable for 24 h. Imaging studies demonstrated high and specific uptake in HER2-positive tumors in mice using this clinical kit formulation. - Highlights: • Kits for preparing 111 In-BzDTPA-pertuzumab were prepared which met specifications for pharmaceutical quality. • The kits were stable for at least 4 months and the final radiopharmaceutical was stable for 24 h when stored at 2–8 °C. • High labeling efficiency (>90%) of the kits was achieved with 111 In. • 111 In-BzDTPA-pertuzumab exhibited stability in human plasma. • Biodistribution and microSPECT imaging showed specific targeting of HER2-positive tumors in mice using the kit formulation

  2. Herceptin Enhances the Antitumor Effect of Natural Killer Cells on Breast Cancer Cells Expressing Human Epidermal Growth Factor Receptor-2

    Directory of Open Access Journals (Sweden)

    Xiao Tian

    2017-10-01

    Full Text Available Optimal adoptive cell therapy (ACT should contribute to effective cancer treatment. The unique ability of natural killer (NK cells to kill cancer cells independent of major histocompatibility requirement makes them suitable as ACT tools. Herceptin, an antihuman epidermal growth factor receptor-2 (anti-HER2 monoclonal antibody, is used to treat HER2+ breast cancer. However, it has limited effectiveness and possible severe cardiotoxicity. Given that Herceptin may increase the cytotoxicity of lymphocytes, we explored the possible augmentation of NK cell cytotoxicity against HER2+ breast cancer cells by Herceptin. We demonstrated that Herceptin could interact with CD16 on NK cells to expand the cytotoxic NK (specifically, CD56dim cell population. Additionally, Herceptin increased NK cell migration and cytotoxicity against HER2+ breast cancer cells. In a pilot study, Herceptin-treated NK cells shrunk lung nodular metastasis in a woman with HER2+ breast cancer who could not tolerate the cardiotoxic side effects of Herceptin. Our findings support the therapeutic potential of Herceptin-treated NK cells in patients with HER2+ and Herceptin-intolerant breast cancer.

  3. Generator-produced alpha-emitters

    International Nuclear Information System (INIS)

    Mirzadeh, S.

    1996-01-01

    This review briefly describes the nuclear characteristics and production parameters for 7.2-h 211 At, 60.6-min 212 Bi, 45.6-min 213 Bi, 11-d 233 Ra, and 20-h 255 Fm. These a-emitting radioisotopes are the subject of current interest for a-particle-mediated radioimmunotherapy

  4. The crystal structure of emilite, Cu10.7Pb10.7Bi21.3S48, the second 45 Å derivative of the bismuthinite-aikinite solid-solution series

    DEFF Research Database (Denmark)

    Balic-Zunic, Tonci; Topa, Dan; Makovicky, Emil

    2002-01-01

    geology, emilite, Cu10.7Pb10.7Bi21.3S48, aikinite-bismuthinite derivative, crystal structure, Felbertal, scheelite deposit, Austria......geology, emilite, Cu10.7Pb10.7Bi21.3S48, aikinite-bismuthinite derivative, crystal structure, Felbertal, scheelite deposit, Austria...

  5. Internalization: acute apoptosis of breast cancer cells using herceptin-immobilized gold nanoparticles

    Directory of Open Access Journals (Sweden)

    Rathinaraj P

    2015-02-01

    Full Text Available Pierson Rathinaraj,1 Ahmed M Al-Jumaily,1 Do Sung Huh21Institute of Biomedical Technologies, Auckland University of Technology, Auckland, New Zealand; 2Department of Nano science and Engineering, Inje University, Gimhea, South KoreaAbstract: Herceptin, the monoclonal antibody, was successfully immobilized on gold nanoparticles (GNPs to improve their precise interactions with breast cancer cells (SK-BR3. The mean size of the GNPs (29 nm, as determined by dynamic light scattering, enlarged to 82 nm after herceptin immobilization. The in vitro cell culture experiment indicated that human skin cells (FB proliferated well in the presence of herceptin-conjugated GNP (GNP–Her, while most of the breast cancer cells (SK-BR3 had died. To elucidate the mechanism of cell death, the interaction of breast cancer cells with GNP–Her was tracked by confocal laser scanning microscopy. Consequently, GNP–Her was found to be bound precisely to the membrane of the breast cancer cell, which became almost saturated after 6 hours incubation. This shows that the progression signal of SK-BR3 cells is retarded completely by the precise binding of antibody to the human epidermal growth factor receptor 2 receptor of the breast cancer cell membrane, causing cell death.Keywords: herceptin, gold nanoparticles, SK-BR3 cells, intracellular uptake

  6. Alpha particle emitters in cancer therapy: establishing the rationale and overcoming the difficulties

    International Nuclear Information System (INIS)

    Sgouros, G.

    1996-01-01

    rapidly accessible disease. Alpha particles will be most useful in situations in which targeting is rapid, killing of isolated single-cells is important and access to normal tissue is minimized. The latter may be achieved by intracavitary administration or by labeling an agent that does not reach normal tissues before the radionuclide has decayed below an acceptable level. Although alpha-particle emitters have shown promise in animal models, they have not been examined in patients. The decay of 212 Bi is accompanied by emission of high energy (2.6 MeV) photons which are difficult to shield; 211 At is cyclotron produced and of limited availability. The initial obstacles to the use of alpha-particle emitters for therapy are availability, handling and radiochemistry. These are being overcome with the introduction of new radionuclides and better radiochemistry. Bismuth-213, for example, is similar to Bi-212 in its alpha particle emissions but does not emit the highly energetic photon seen with Bi-212. Once the initial, logistical obstacles are surmounted, the dosimetry and normal tissue toxicity must be investigated

  7. Epidermal growth factor receptor coexpression modulates susceptibility to Herceptin in HER2/neu overexpressing breast cancer cells via specific erbB-receptor interaction and activation

    International Nuclear Information System (INIS)

    Diermeier, Simone; Horvath, Gabor; Knuechel-Clarke, Ruth; Hofstaedter, Ferdinand; Szoellosi, Janos; Brockhoff, Gero

    2005-01-01

    Background: Growth factors and Herceptin specifically and differentially modulate cell proliferation of tumor cells. However, the mechanism of action on erbB-receptor level is incompletely understood. We evaluated Herceptin's capacity to modulate erbB-receptor activation and interaction on the cell surface level and thereby potentially impair cell proliferation of HER2/neu (c-erbB2) overexpressing breast cancer cells, both in the presence and absence of relevant growth factors. Methods: BT474 and SK-BR-3 breast cancer cell lines were treated with Epidermal Growth Factor (EGF), Heregulin, and with Herceptin in different combinations. Kinetics of cell proliferation were evaluated flow cytometrically based on BrdU-labeling. Fluorescence Resonance Energy Transfer, ELISAs and phosphorylation site specific Western Blotting was performed to investigate erbB-receptor interaction and activation. Results: EGF induced EGFR/EGFR and EGFR/c-erbB2 interactions correlate with stimulation of cell proliferation in BT474 cells. Both homo- and heterodimerization are considerably less pronounced in SK-BR-3 cells and heterointeraction is additionally reduced by EGF treatment, causing inhibition of cell proliferation. Heregulin stimulates cell proliferation extensively in both cell lines. Herceptin drives BT474 cells more efficiently into quiescence than it does with SK-BR-3 cells and thereby blocks cell cycle progress. In SK-BR-3 Herceptin treatment causes c-erbB2 phosphorylation of Y877 and Y1248, EGF induces Y877 and Y1112 phosphorylation. The Y1112 phosphorylation site, activated by EGF in SK-BR-3 cell, is bypassed in BT474. In addition the inhibitory capacity of Herceptin on BT474 and SK-BR-3 cell proliferation depends on the presence and absence of growth factors to a various extent. Conclusion: The growth inhibitory effect of Herceptin on c-erbB2 overexpressing breast cancer cells is considerably modulated by EGFR coexpression and consequently EGFR/c-erbB2 homo- and

  8. Microdosimetry of monoclonal antibodies labeled with alpha emitters

    International Nuclear Information System (INIS)

    Fisher, D.R.

    1986-01-01

    The recent discovery of new techniques for the production of monoclonal antibodies (MoAB) has opened up a number of potential new applications in cancer diagnosis and therapy. Monoclonal antibodies labeled with alpha-emitting radionuclides promise to be particularly effective therapeutic agents due to the efficient cell killing ability of highly ionizing, short-range alpha particle tracks localized at specific antigen sites within the tumor mass. For a radioimmunotherapy treatment plan to be effective, one must be able to estimate the absorbed radiation dose to both tumor cells and normal tissues in the body. However, conventional methods used in nuclear medicine for estimating absorbed doses and specific absorbed fractions for radiopharmaceuticals do not apply to alpha emitters owing to their short range and the large variations in the local distribution of energy at the cellular level that result. Microdosimetric techniques developed for assessment of the radiological effects of internally deposited transuranic radionuclides take into account the statistical aspects of alpha particle track structure, energy distribution patterns, and radionuclide distribution within tissues, and provide a means for determining the number and frequency of cells irradiated, the probability densities in specific energy, and the average dose delivered to cells of interest. These techniques can be applied to the study of radiation absorbed dose from alpha-labeled monoclonal antibodies. 16 references, 6 figures

  9. High affinity antigen recognition of the dual specific variants of herceptin is entropy-driven in spite of structural plasticity.

    Directory of Open Access Journals (Sweden)

    Jenny Bostrom

    Full Text Available The antigen-binding site of Herceptin, an anti-human Epidermal Growth Factor Receptor 2 (HER2 antibody, was engineered to add a second specificity toward Vascular Endothelial Growth Factor (VEGF to create a high affinity two-in-one antibody bH1. Crystal structures of bH1 in complex with either antigen showed that, in comparison to Herceptin, this antibody exhibited greater conformational variability, also called "structural plasticity". Here, we analyzed the biophysical and thermodynamic properties of the dual specific variants of Herceptin to understand how a single antibody binds two unrelated protein antigens. We showed that while bH1 and the affinity-improved bH1-44, in particular, maintained many properties of Herceptin including binding affinity, kinetics and the use of residues for antigen recognition, they differed in the binding thermodynamics. The interactions of bH1 and its variants with both antigens were characterized by large favorable entropy changes whereas the Herceptin/HER2 interaction involved a large favorable enthalpy change. By dissecting the total entropy change and the energy barrier for dual interaction, we determined that the significant structural plasticity of the bH1 antibodies demanded by the dual specificity did not translate into the expected increase of entropic penalty relative to Herceptin. Clearly, dual antigen recognition of the Herceptin variants involves divergent antibody conformations of nearly equivalent energetic states. Hence, increasing the structural plasticity of an antigen-binding site without increasing the entropic cost may play a role for antibodies to evolve multi-specificity. Our report represents the first comprehensive biophysical analysis of a high affinity dual specific antibody binding two unrelated protein antigens, furthering our understanding of the thermodynamics that drive the vast antigen recognition capacity of the antibody repertoire.

  10. Trastuzumab-associated cardiac adverse effects in the herceptin adjuvant trial

    NARCIS (Netherlands)

    Suter, Thomas M.; Procter, Marion; van Veldhuisen, Dirk J.; Muscholl, Michael; Bergh, Jonas; Carlomagno, Chiara; Perren, Timothy; Passalacqua, Rodolfo; Bighin, Claudia; Klijn, Jan G. M.; Ageev, Fail T.; Hitre, Erika; Groetz, Juergen; Iwata, Hiroji; Knap, Malgorzata; Gnant, Michael; Muehlbauer, Susanne; Spence, Alison; Gelber, Richard D.; Piccart-Gebhart, Martine J.

    2007-01-01

    Purpose The purpose of this analysis was to investigate trastuzumab- associated cardiac adverse effects in breast cancer patients after completion of ( neo) adjuvant chemotherapy with or without radiotherapy. Patients and Methods The Herceptin Adjuvant ( HERA) trial is a three- group, multicenter,

  11. Final Report for research grant entitled 'Development of Reagents for Application of At-211 and Bi-213 to Targeted Radiotherapy of Cancer'

    International Nuclear Information System (INIS)

    Wilbur, D. Scott

    2011-01-01

    This grant was a one-year extension of another grant with the same title (DE-FG03-98ER62572). The objective of the studies was to continue in vivo evaluation of reagents to determine which changes in structure were most favorable for in vivo use. The focus of our studies was development and optimization of reagents for pretargeting alpha-emitting radionuclides At-211 or Bi-213 to cancer cells. Testing of the reagents was conducted in vitro and in animal model systems. During the funding period, all three specific aims set out in the proposed studies were worked on, and some additional studies directed at development of a method for direct labeling of proteins with At-211 were investigated. We evaluated reagents in two different approaches in 'two step' pretargeting protocols. These approaches are: (1) delivery of the radionuclide on recombinant streptavidin to bind with pretargeted biotinylated monoclonal antibody (mAb), and alternatively, (2) delivery of the radionuclide on a biotin derivative to bind with pretargeted antibody-streptavidin conjugates. The two approaches were investigated as it was unclear which will be superior for the short half-lived alpha-emitting radionuclides.

  12. Final Report for research grant entitled "Development of Reagents for Application of At-211 and Bi-213 to Targeted Radiotherapy of Cancer"

    Energy Technology Data Exchange (ETDEWEB)

    Wilbur, D. Scott

    2011-12-23

    This grant was a one-year extension of another grant with the same title (DE-FG03-98ER62572). The objective of the studies was to continue in vivo evaluation of reagents to determine which changes in structure were most favorable for in vivo use. The focus of our studies was development and optimization of reagents for pretargeting alpha-emitting radionuclides At-211 or Bi-213 to cancer cells. Testing of the reagents was conducted in vitro and in animal model systems. During the funding period, all three specific aims set out in the proposed studies were worked on, and some additional studies directed at development of a method for direct labeling of proteins with At-211 were investigated. We evaluated reagents in two different approaches in 'two step' pretargeting protocols. These approaches are: (1) delivery of the radionuclide on recombinant streptavidin to bind with pretargeted biotinylated monoclonal antibody (mAb), and alternatively, (2) delivery of the radionuclide on a biotin derivative to bind with pretargeted antibody-streptavidin conjugates. The two approaches were investigated as it was unclear which will be superior for the short half-lived alpha-emitting radionuclides.

  13. Media Hyping and the "Herceptin Access Story": An Analysis of Canadian and UK Newspaper Coverage.

    Science.gov (United States)

    Abelson, Julia; Collins, Patricia A

    2009-02-01

    In May 2005, preliminary trial results pronouncing the effectiveness of Herceptin (trastuzumab) for treatment of early-stage breast cancer were disseminated at a high-profile scientific meeting. Herceptin was subsequently approved for use in the public healthcare systems of Canada and the United Kingdom, although the differences between the two decision timelines were stark. The authors compared UK and Canadian newspaper coverage of the Herceptin story to assess how it may have been "hyped" in each country. They analyzed a diverse sample of newspapers and coded clippings for reporters' framing of the drug's efficacy, costs and funding approval process. Canadian news coverage preceded formal publication of the trial results, while UK coverage mirrored major national events. Reporters in both countries used predominantly individualistic perspectives and framed Herceptin's efficacy in salutary terms. Framing of costs was more neutral in Canadian than in UK newspapers. Funding approval framing focused on inequitable access in the UK and timeliness in Canada. News coverage of drug access stories varies across jurisdictions in terms of intensity and some aspects of framing. Such variations likely reflect different journalistic practices and dominant political rhetoric. Greater attention should be given to the role that news coverage of drug access plays in shaping public opinion and policy action, especially when this coverage precedes scientific debate. Copyright © 2009 Longwoods Publishing.

  14. Phosphodiesterase type 5 inhibitors increase Herceptin transport and treatment efficacy in mouse metastatic brain tumor models.

    Directory of Open Access Journals (Sweden)

    Jinwei Hu

    2010-04-01

    Full Text Available Chemotherapeutic drugs and newly developed therapeutic monoclonal antibodies are adequately delivered to most solid and systemic tumors. However, drug delivery into primary brain tumors and metastases is impeded by the blood-brain tumor barrier (BTB, significantly limiting drug use in brain cancer treatment.We examined the effect of phosphodiesterase 5 (PDE5 inhibitors in nude mice on drug delivery to intracranially implanted human lung and breast tumors as the most common primary tumors forming brain metastases, and studied underlying mechanisms of drug transport. In vitro assays demonstrated that PDE5 inhibitors enhanced the uptake of [(14C]dextran and trastuzumab (Herceptin, a humanized monoclonal antibody against HER2/neu by cultured mouse brain endothelial cells (MBEC. The mechanism of drug delivery was examined using inhibitors for caveolae-mediated endocytosis, macropinocytosis and coated pit/clathrin endocytosis. Inhibitor analysis strongly implicated caveolae and macropinocytosis endocytic pathways involvement in the PDE5 inhibitor-enhanced Herceptin uptake by MBEC. Oral administration of PDE5 inhibitor, vardenafil, to mice with HER2-positive intracranial lung tumors led to an increased tumor permeability to high molecular weight [(14C]dextran (2.6-fold increase and to Herceptin (2-fold increase. Survival time of intracranial lung cancer-bearing mice treated with Herceptin in combination with vardenafil was significantly increased as compared to the untreated, vardenafil- or Herceptin-treated mice (p0.05.These findings suggest that PDE5 inhibitors may effectively modulate BTB permeability, and enhance delivery and therapeutic efficacy of monoclonal antibodies in hard-to-treat brain metastases from different primary tumors that had metastasized to the brain.

  15. Label-Free Biosensors Based on Bimodal Waveguide (BiMW) Interferometers.

    Science.gov (United States)

    Herranz, Sonia; Gavela, Adrián Fernández; Lechuga, Laura M

    2017-01-01

    The bimodal waveguide (BiMW) sensor is a novel common path interferometric transducer based on the evanescent field detection principle, which in combination with a bio-recognition element allows the direct detection of biomolecular interactions in a label-free scheme. Due to its inherent high sensitivity it has great potential to become a powerful analytical tool for monitoring substances of interest in areas such as environmental control, medical diagnostics and food safety, among others. The BiMW sensor is fabricated using standard silicon-based technology allowing cost-effective production, and meeting the requirements of portability and disposability necessary for implementation in a point-of-care (POC) setting.In this chapter we describe the design and fabrication of the BiMW transducer, as well as its application for bio-sensing purposes. We show as an example the biosensor capabilities two different applications: (1) the immunodetection of Irgarol 1051 biocide useful in the environmental field, and (2) the detection of human growth hormone as used in clinical diagnostics. The detection is performed in real time by monitoring changes in the intensity pattern of light exiting the BiMW transducer resulting from antigen-antibody interactions on the surface of the sensor.

  16. Synthesis and evaluation of tetraphosphonates labelled with 212Bi, 212Pb and 165Er

    International Nuclear Information System (INIS)

    Hassfjell, S.P.

    1997-08-01

    The main goal of this work has been to achieve a synthesis of radiolabelled phosphonates for the improvement of diagnostic and therapy of osteoblastic osteosarcoma and sclerotic bone metastases. 212 Bi-DOTMP is shown to be an in vivo stable bone seeking radiopharmaceutical with a potential for a α-particle therapy of the above mentioned diseases. It has biodistribution characteristics similar to 153 Sm-EDTMP, which is now formally approved in several countries, most recently in the US. 212 Pb-DOTMP is also a promising candidate having the advantage of increasing the effective half life of the α-emitter, although loss of some of the in vivo generated 212 Bi may be a problem. A generator has been developed for the production of the α-emitting radionuclide 212 Bi and its parent nuclide 212 Pb. The generator is based on the emanation of 220 Rn from ( 228 Th)barium stearate. The decay product of 220 Rn, 212 Pb deposits on the walls of a polyethylene bottle, and can be wasted off with distilled water. The generator shows no leakage of any long-lived parent nuclides, is easy to operate and has a high degree of radiation safety

  17. Gadolinium and fluorescent bi-functionally labeling and in vitro MRI of rat bone marrow mesenchymal stem cells

    International Nuclear Information System (INIS)

    Shen Jun; Zhou Cuiping; Cheng Li'na; Duan Xiaohui; Liang Biling; Fu Yue; Bi Xiaobin; Liu Yu; Deng Yubin

    2008-01-01

    Objective: To determine the feasibility of magnetically labeling and tracking mesenchymal stem cells (MSCs) in vitro by using a gadolinium and fluorescent bi-functionally transfection agent of polyethylenimine. Methods: A gadolinium bifunctional transfection reagent complex was obtained after the linear polyethylenimine derivative (JetPEI-FluoR) was incubated with Gd-DTPA. Mesenchymal stem cells isolated from the bone marrows of SD rats were cultured and expanded. The mesenchymal stem cells were incubated with the bi-functional labeling agents. After labeling, the MSCs were examined with fluoroscope and electron microscope and the biological characters were detected including trypan blue exclusion test, MTT, and apoptosis detection. On a 1.5 T MR system, the labeled MSCs were examined with spin echo T 1 WI and T 2 WI and T 1 measurement with mixed sequence. After labeling, the cells were cultured and undergone routine passage. Prior MR examinations were repeated for each passage of labeled cells. All data was statistically prolessed with SPSS for Windows. Results: Of 5 x 10 5 MSCs incubated with the bi-functional agents, 4.25 x 10 5 MSCs were successfully labeled, the percentage of labeled MSCs was 85% fluoroscopically. The high density electron particles of gadolinium observed electron microscopically existed around cellular apparatuses, especially around Golgi apparatus. In trypan blue exclusion test, the exclusion rate of labeled MSCs with incubation duration of 3,6,12,24 h was (96.55±2.90)%, (94.17± 2.56)%, (97.16±3.12)% and (94.23±2.67)%, respectively. The corresponding exclusion rate of unlabeled MSCs was (95.86±2.67)%, (92.04±2.21)%, (93.38±3.64)% and (92.12±2.53)%, respectively. There was no statistical difference of trypan blue exclusion rate between labeled cells and control unlabeled cells within 24 hours of incubation (F=4.523, P>0.05). In the proliferation test, the optical absorption value of labeled MSC with 2.5, 5.0, 10.0, 20.0, 30.0 and 40

  18. The Potential Utility of Curcumin in the Treatment of HER-2-Overexpressed Breast Cancer: An In Vitro and In Vivo Comparison Study with Herceptin

    Directory of Open Access Journals (Sweden)

    Hung-Wen Lai

    2012-01-01

    Full Text Available HER-2 is an important oncoprotein overexpressed in about 15–25% of breast cancers. We hypothesized that the ability of curcumin to downregulate HER-2 oncoprotein and inhibit the signal transduction pathway of PI3K/Akt, MAPK, and NF-κB activation may be important in the treatment of HER-2-overexpressed breast cancer. To examine the effect of curcumin on breast cancer cells, MCF-7, MDA-MB-231, MCF-10A, BT-474, and SK-BR-3-hr (a herceptin resistant strain from SK-BR-3 cells were used for in vitro analysis. The in vivo effect of curcumin on HER-2-overexpressed breast cancer was investigated with the HER-2-overexpressed BT-474 xenograft model. Cell growth, cell cycle change, the antimobility effect, signal transduction, and xenograft volume analysis between groups treated with herceptin and/or curcumin were tested. Curcumin decreased the cell growth of various breast cancer cell lines (MCF-7, MDA-MB-231, MCF-10A, BT-474, and SK-BR-3-hr. In Western blot analysis, the phosphorylation of Akt, MAPK, and expression of NF-κB were reduced in BT-474 cells, but not in SK-BR-3-hr cells, after treatment with herceptin. When treated with curcumin, the HER-2 oncoprotein, phosphorylation of Akt, MAPK and expression of NF-κB were decreased in both BT-474 and SK-BR-3-hr cells. In the BT-474 xenograft model, though not as much as herceptin, curcumin did effectively decrease the tumor size. The combination of curcumin with herceptin was not better than herceptin alone; however, the combination of taxol and curcumin had an antitumor effect comparable with taxol and herceptin. The results suggested that curcumin has potential as a treatment for HER-2-overexpressed breast cancer.

  19. Reciprocal regulation of annexin A2 and EGFR with Her-2 in Her-2 negative and herceptin-resistant breast cancer.

    Directory of Open Access Journals (Sweden)

    Praveenkumar K Shetty

    Full Text Available Alternative survival pathways are commonly seen to be upregulated upon inhibition of receptor tyrosine kinases (RTK, including Her-2. It is established that treatment with Herceptin leads to selective overexpression and activation of epidermal growth factor receptor (EGFR and Src which further contributes to oncogenesis in Herceptin resistant and triple negative breast cancer (TNBC patients. Here, we show a co-regulated upregulation in the expression of Annexin A2 (AnxA2, a known substrate of Src and one of the regulators of EGFR receptor endocytosis, in Herceptin resistant and Her-2 negative breast cancer. Immunohistochemical expression analysis revealed a reciprocal regulation between Her-2 and AnxA2 in breast cancer clinical samples as well as in cell lines as confirmed by protein and RNA analysis. The siRNA and Herceptin mediated downregulation/inhibition of Her-2 in Her-2 amplified cells induced AnxA2 expression and membrane translocation. In this study we report a possible involvement of AnxA2 in maintaining constitutively activated EGFR downstream signaling intermediates and hence in cell proliferation, migration and viability. This effect was consistent in Herceptin resistant JIMT-1 cells as well as in Her-2 negative breast cancer. The siRNA mediated AnxA2 downregulation leads to increased apoptosis, decreased cell viability and migration. Our studies further indicate the role of AnxA2 in EGFR-Src membrane bound signaling complex and ligand induced activation of downstream signaling pathways. Targeting this AnxA2 dependent positive regulation of EGFR signaling cascade may be of therapeutic value in Her-2 negative breast cancer.

  20. Preparation and preclinical evaluation of 211At-labelled compounds for α-particle radiotherapy

    International Nuclear Information System (INIS)

    Larsen, R.H.

    1994-01-01

    The interest for α-particle emitters in internal radiotherapy is increasing due to improved conjugation chemistry. Experimental work has concentrated on 211 At and 212 Bi since these to nuclides have radiochemical and physical properties suitable for medical application. In this report it is demonstrated that biologically active 211 At-labelled compounds can be prepared within a relatively short time allowing utilization of this 7.2 h α-particle. It is further shown that 211 At-TP-3 treatment of human osteosarcoma in vitro gives promising therapeutic ratios. 76 refs., 5 figs., 3 tabs

  1. A combination of SILAC and nucleotide acyl phosphate labelling reveals unexpected targets of the Rsk inhibitor BI-D1870.

    Science.gov (United States)

    Edgar, Alexander J; Trost, Matthias; Watts, Colin; Zaru, Rossana

    2014-02-01

    Protein kinase inhibitors frequently have interesting effects that cannot be fully ascribed to the intended target kinase(s) but identifying additional targets that might explain the effects is not straightforward. By comparing two different inhibitors of the Rsk (p90 ribosomal S6 kinase) kinases, we found that the increasingly used compound BI-D1870 had biological effects in murine DCs (dendritic cells) that could not be solely ascribed to Rsk or other documented targets. We assessed the ability of BI-D1870 and a second Rsk inhibitor, BIX 02565 to protect enzyme active sites from reaction with biotinylated nucleotide acyl phosphates. Using SILAC (stable isotope labelling by amino acids in cell culture)-labelled DC lysates as a source of enzyme targets, we identify several kinases that interact with BI-D1870 but not with BIX 02565. We confirmed that these kinases, including Slk, Lok and Mst1, are inhibited by BI-D1870 but to a much lesser extent by BIX 02565 and that phosphorylation of some of their substrates is blocked by BI-D1870 in living cells. Our results suggest that the BI-D1870 inhibitor should be used with caution. The SILAC-based methodology we used should be useful for further comparative unbiased profiling of the target spectrum of kinase inhibitors with interesting biological effects under conditions that closely mimic those found in cells. © 2014 The author(s).

  2. Synthesis and evaluation of tetraphosphonates labelled with {sup 212}Bi, {sup 212}Pb and {sup 165}Er

    Energy Technology Data Exchange (ETDEWEB)

    Hassfjell, S.P

    1997-08-01

    The main goal of this work has been to achieve a synthesis of radiolabelled phosphonates for the improvement of diagnostic and therapy of osteoblastic osteosarcoma and sclerotic bone metastases. {sup 212}Bi-DOTMP is shown to be an in vivo stable bone seeking radiopharmaceutical with a potential for a {alpha}-particle therapy of the above mentioned diseases. It has biodistribution characteristics similar to {sup 153}Sm-EDTMP, which is now formally approved in several countries, most recently in the US. {sup 212}Pb-DOTMP is also a promising candidate having the advantage of increasing the effective half life of the {alpha}-emitter, although loss of some of the in vivo generated {sup 212}Bi may be a problem. A generator has been developed for the production of the {alpha}-emitting radionuclide {sup 212}Bi and its parent nuclide {sup 212}Pb. The generator is based on the emanation of {sup 220}Rn from ({sup 228}Th)barium stearate. The decay product of {sup 220}Rn, {sup 212}Pb deposits on the walls of a polyethylene bottle, and can be wasted off with distilled water. The generator shows no leakage of any long-lived parent nuclides, is easy to operate and has a high degree of radiation safety.

  3. Preparation and preclinical evaluation of {sup 211}At-labelled compounds for {alpha}-particle radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, R H

    1994-12-31

    The interest for {alpha}-particle emitters in internal radiotherapy is increasing due to improved conjugation chemistry. Experimental work has concentrated on {sup 211}At and {sup 212}Bi since these to nuclides have radiochemical and physical properties suitable for medical application. In this report it is demonstrated that biologically active {sup 211}At-labelled compounds can be prepared within a relatively short time allowing utilization of this 7.2 h {alpha}-particle. It is further shown that {sup 211}At-TP-3 treatment of human osteosarcoma in vitro gives promising therapeutic ratios. 76 refs., 5 figs., 3 tabs.

  4. Assessment of the tumor load as well as toxic and side effects after herceptin combined with doxorubicin liposome treatment of HER-2 positive breast cance

    Directory of Open Access Journals (Sweden)

    Guo-Quan Wen

    2016-12-01

    Full Text Available Objective: To study the effect of herceptin combined with doxorubicin liposome treatment on tumor load as well as toxic and side effects of HER-2 positive breast cancer. Methods: A total of 138 patients with HER-2 positive breast cancer who received chemotherapy in our hospital between July 2014 and December 2015 were selected as the research subjects and randomly divided into two groups, liposome group received herceptin combined with doxorubicin liposome treatment and control group received herceptin combined with doxorubicin treatment. After 8 weeks of treatment, the content of tumor markers, active molecules and myocardial injury markers in serum as well as the expression levels of immune marker molecules in peripheral blood mononuclear cells were detected. Results: After 8 weeks of treatment, CEA, CA199, CA153, CA125, VEGF, nectin-4, TK-1, PF-4, TSGF, CK, CK-MB, cTnI and cTnT content in serum of liposome group were significantly lower than those of control group, and the fluorescence intensity of CD3, CD4, CD8, CD16, CD19 and CD25 on peripheral blood mononuclear cell surface were significantly higher than those of control group. Conclusions: Herceptin combined with doxorubicin liposome treatment of HER-2 positive breast cancer can more effectively reduce the tumor load and cause less toxic and side effects on the heart and the immune system.

  5. Compartmental and dosimetric studies of anti-CD20 labelled with 188Re

    International Nuclear Information System (INIS)

    Kuramoto, Graciela Barrio

    2016-01-01

    The radioimmunotherapy (RIT) uses MAbs conjugated to radionuclides α or β - emitters, both for therapy. Your treatment is based on the irradiation and tumor destruction, preserving the normal organs as the excess radiation. Radionuclides β - emitters as 131 I, 90 Y, 188 Re 177 Lu and are useful for the development of therapeutic radiopharmaceuticals and, when coupled with MAb and Anti-CD20 it is important mainly for the treatment of non-Hodgkin's lymphomas (NHL). 188 Re (E β = 2.12 MeV; E γ = 155 keV; t1/2 = 16.9 h) is an attractive radionuclide for RIT. However, 188 Re can be obtained from a radionuclide generator of 188 W/ 188 Re, commercially available, making it convenient for use in research and for clinical routine. The CR of IPEN has a project aimed at the production of radiopharmaceutical 188 Re-Anti-CD20, where the radionuclide can be obtained from a generator system 188 W/ 188 Re. With this proposed a study to assess the efficiency of this labeling technique for treatment in accordance compartmental and dosimetry. The objective of this study was to compare the marking of anti-CD20 MAb with 188 Re with the marking of the antibody with 90 Y, 131 I, 177 Lu and 99m Tc (for their similar chemical characteristics) and 211 At, 213 Bi, 223 Ra and 225 Ac); through the study of labeling techniques reported in literature, the proposal of a compartmental model to evaluate its pharmacokinetic and dosimetric studies, high interest for therapy. The result of the study shows a favorable kinetics for 188 Re, by their physical and chemical characteristics compared to the other evaluated radionuclides. The compartment proposed study describes the metabolism of 188 Reanti- CD20 through a compartment mammillary model, which by their pharmacokinetic analysis, performed compared to products emitters β -131 I-labeled anti CD20, 177 Luanti- CD20, the γ emitter 99m Tc-Anti-CD20 and α emitter 211 At-Anti-CD20 presented a elimination constant of approximately 0.05 hours

  6. Evaluation and application of the low energy electron emitter 161Tb

    International Nuclear Information System (INIS)

    Lehenberger, Silvia M.

    2010-01-01

    The low energy electron emitter 161 Tb was produced n.c.a. in quantities sufficient for therapeutic applications and successfully used for labeling of peptides and antibodies. Furthermore, these compounds have been compared to n.c.a. 177 Lu labeled mAbs via cell experiments, a radionuclide that is already used in clinical nuclear oncology.

  7. Drifts in ADCC-related quality attributes of Herceptin?: Impact on development of a trastuzumab biosimilar

    OpenAIRE

    Kim, Seokkyun; Song, Jinsu; Park, Seungkyu; Ham, Sunyoung; Paek, Kyungyeol; Kang, Minjung; Chae, Yunjung; Seo, Heewon; Kim, Hyung-Chan; Flores, Michael

    2017-01-01

    ABSTRACT A biosimilar product needs to demonstrate biosimilarity to the originator reference product, and the quality profile of the latter should be monitored throughout the period of the biosimilar's development to match the quality attributes of the 2 products that relate to efficacy and safety. For the development of a biosimilar version of trastuzumab, the reference product, Herceptin?, was extensively characterized for the main physicochemical and biologic properties by standard or stat...

  8. RF emittance in a low energy electron linear accelerator

    Science.gov (United States)

    Sanaye Hajari, Sh.; Haghtalab, S.; Shaker, H.; Kelisani, M. Dayyani

    2018-04-01

    Transverse beam dynamics of an 8 MeV low current (10 mA) S-band traveling wave electron linear accelerator has been studied and optimized. The main issue is to limit the beam emittance, mainly induced by the transverse RF forces. The linac is being constructed at Institute for Research in Fundamental Science (IPM), Tehran Iran Labeled as Iran's First Linac, nearly all components of this accelerator are designed and constructed within the country. This paper discusses the RF coupler induced field asymmetry and the corresponding emittance at different focusing levels, introduces a detailed beam dynamics design of a solenoid focusing channel aiming to reduce the emittance growth and studies the solenoid misalignment tolerances. In addition it has been demonstrated that a prebuncher cavity with appropriate parameters can help improving the beam quality in the transverse plane.

  9. Novel Toll-like receptor-4 deficiency attenuates trastuzumab (Herceptin induced cardiac injury in mice

    Directory of Open Access Journals (Sweden)

    Yousif Nasser

    2011-10-01

    Full Text Available Abstract Background Cardiac inflammation and generation of oxidative stress are known to contribute to trastuzumab (herceptin induced cardiac toxicity. Toll-like receptors (TLRs are a part of the innate immune system and are involved in cardiac stress reactions. Since TLR4 might play a relevant role in cardiac inflammatory signaling, we investigated whether or not TLR4 is involved in trastuzumab induced cardiotoxicity. Methods Seven days after a single injection of herceptin (2 mg/kg; i.p., left ventricular pressure volume loops were measured in HeN compotent (TLR4+/+ and HeJ mutant (TLR4-/- treated with trastuzumab and control mice. Immunofluorescent staining for monocyte infiltration and analyses of plasma by (ELISAs for different chemokines including: MCP-1and tumor necrosis factor-α (TNF-α, Western immunoblotting assay for ICAM-1, and used troponin I for cardiac injury marker. Results Trastuzumab injection resulted in an impairment of left ventricular function in TLR-4 competent (HeN, in contrast TLR4-/- trastuzumab mice showed improved left ventricular function EF%, CO; p -/-; p -/-, marked reduction of myocardial troponin-I levels in TLR4-deficient mice. Data are presented as means ± SE; n = 8 in each group p Conclusions Treatment with trastuzumab induces an inflammatory response that contributes to myocardial tissue TLR4 mediates chemokine expression (TNF-α, MCP-1and ICAM-1, so in experimental animals TLR4 deficiency improves left ventricular function and attenuates pathophysiological key mechanisms in trastuzumab induced cardiomyopathy.

  10. Interactive session: alpha emitters, fashion or reality? radionuclides and molecules availability

    International Nuclear Information System (INIS)

    Zimmermann, R.

    2015-01-01

    Full text of publication follows. This introduction to the interactive session will simply be based on statements related to the future of therapy in nuclear medicine with some emphasis on the use of alpha-emitters. Some hypotheses will be developed on topics such as 'How will look nuclear medicine in 2025?', 'Do we have enough information to support the use of alpha in therapy?' 'Does it make sense to develop alpha-labelled molecules without long term financial commitment?', 'Will sufficient amounts of radionuclides available when the drugs will be ready for marketing?', 'Do we know enough about alpha emitters toxicity?', 'Is personalized medicine really the solution of the future of health care?', 'How can we convince authorities about the advantages of alpha labelled molecules?', 'Is the development of alpha RIT more expensive or more difficult than beta RIT?', 'Where are all the beta-emitter under development gone?', 'With alpha-emitters, are we speaking about 2025 or 2050?', 'Will Xofigo be a success?', 'What will be the real role of pharmaceutical companies in radiotherapy?', 'Who are the most afraid about radioactivity, the patients or the authorities?'. The speaker will provide his own opinion about each topic. Will you agree or not with him? What is your opinion? (author)

  11. Asymmetrical field emitter

    Science.gov (United States)

    Fleming, J.G.; Smith, B.K.

    1995-10-10

    A method is disclosed for providing a field emitter with an asymmetrical emitter structure having a very sharp tip in close proximity to its gate. One preferred embodiment of the present invention includes an asymmetrical emitter and a gate. The emitter having a tip and a side is coupled to a substrate. The gate is connected to a step in the substrate. The step has a top surface and a side wall that is substantially parallel to the side of the emitter. The tip of the emitter is in close proximity to the gate. The emitter is at an emitter potential, and the gate is at a gate potential such that with the two potentials at appropriate values, electrons are emitted from the emitter. In one embodiment, the gate is separated from the emitter by an oxide layer, and the emitter is etched anisotropically to form its tip and its asymmetrical structure. 17 figs.

  12. Emittance preservation

    Energy Technology Data Exchange (ETDEWEB)

    Kain, V; Arduini, G; Goddard, B; Holzer, B J; Jowett, J M; Meddahi, M; Mertens, T; Roncarolo, F; Schaumann, M; Versteegen, R; Wenninger, J [European Organization for Nuclear Research, Geneva (Switzerland)

    2012-07-01

    Emittance measurements during the LHC proton run 2011 indicated a blow-up of 20 % to 30 % from LHC injection to collisions. This presentation will show the emittance preservation throughout the different parts of the LHC cycle and discuss the current limitations on emittance determination. An overview of emittance preservation through the injector complex as function of bunch intensity will also be given. Possible sources for the observed blow-up and required tests in 2012 will be presented. Possible improvements of emittance diagnostics and analysis tools for 2012 will be shown.

  13. Overview of the trastuzumab (Herceptin) anti-HER2 monoclonal antibody clinical program in HER2-overexpressing metastatic breast cancer. Herceptin Multinational Investigator Study Group.

    Science.gov (United States)

    Shak, S

    1999-08-01

    The recombinant humanized anti-HER2 monoclonal antibody trastuzumab (Herceptin; Genentech, San Francisco, CA) was evaluated in human clinical trials for treatment of women with metastatic breast cancer who have tumors that overexpress HER2. The trastuzumab clinical program consisted of a series of phase I, phase II, and phase III clinical trials. Clinical experience with this novel biologic has been obtained in more than 1,000 women with HER2-overexpressing metastatic breast cancer. Two pivotal trials were performed to evaluate trastuzumab efficacy and safety: (1) trastuzumab in combination with chemotherapy as first-line therapy and (2) trastuzumab as a single agent in second- and third-line chemotherapy. Preliminary results of the pivotal clinical trials that have been presented at national meetings are summarized below. The data suggest that trastuzumab will be an important new treatment option for women with HER2-overexpressing metastatic breast cancer.

  14. Immuno-vectorization of radioelements emitters of alpha particles: a new therapy in cancerology

    International Nuclear Information System (INIS)

    Bourgeois, M.

    2007-05-01

    The radio-immunotherapy is an anti cancerous therapy which consists in vectorising with immuno-specific agents very radio toxic radioelements on tumors or in their environment to destroy them. The first part of this report presents the different characteristics of antibodies as well as their means of production under monoclonal shapes specifically steered against a tumoral antigen of interest. The second part of this report replaces the importance of the immunological vectors in the context of the nuclear medicine. It is notably described that the different methods which allow to radio-label the vector, as well as the different ways of optimization which were envisaged to improve the targeting of radioelements on a tumor. These different developments allow to define the potential place of the alpha radio-immunotherapy in treatments and so re-place the interest of the experimental part. If the radio-immunotherapy, using beta emitters isotopes as the 131 iodine or the 90 yttrium, is today current in anti cancerous therapy, it finds limits because of the disintegration characteristics of the isotopes it uses. Indeed, compared with alpha particles, the beta particles deposit less energy by unit of length in the crossed material.The experimental part of this report aims at studying the feasibility of the coupling between an immunological vector and an alpha emitter isotope.The different tests led on the bismuth 213, the bismuth 212, the lead 212 and the astatine 211 demonstrated that the fixation of these radionuclides was possible. This research theme is strengthened by the construction in Nantes of a cyclotron with high energy ( A.R.R.O.N.A.X.) and the optimization of the obtained promising results should allow a therapeutic use in oncology of the alpha radio-immunotherapy. (N.C.)

  15. Live visualization of genomic loci with BiFC-TALE.

    Science.gov (United States)

    Hu, Huan; Zhang, Hongmin; Wang, Sheng; Ding, Miao; An, Hui; Hou, Yingping; Yang, Xiaojing; Wei, Wensheng; Sun, Yujie; Tang, Chao

    2017-01-11

    Tracking the dynamics of genomic loci is important for understanding the mechanisms of fundamental intracellular processes. However, fluorescent labeling and imaging of such loci in live cells have been challenging. One of the major reasons is the low signal-to-background ratio (SBR) of images mainly caused by the background fluorescence from diffuse full-length fluorescent proteins (FPs) in the living nucleus, hampering the application of live cell genomic labeling methods. Here, combining bimolecular fluorescence complementation (BiFC) and transcription activator-like effector (TALE) technologies, we developed a novel method for labeling genomic loci (BiFC-TALE), which largely reduces the background fluorescence level. Using BiFC-TALE, we demonstrated a significantly improved SBR by imaging telomeres and centromeres in living cells in comparison with the methods using full-length FP.

  16. [sup 205]Bi/[sup 206]Bi cyclotron production from Pb-isotopes for absorption studies in humans

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, R.; Dresow, B.; Heinrich, H.C. (Universitaetskrankenhaus Eppendorf, Hamburg (Germany). Abt. Medizinische Biochemie); Wendel, J.; Bechtold, V. (Kernforschungszentrum Karlsruhe GmbH (Germany). Inst. fuer Kernphysik)

    1993-12-01

    Pb(p,xn) thick target excitation functions were measured in the energy range 10-38 MeV in order to optimize the production of isotopically pure radiobismuth from [sup nat]Pb, [sup 206]Pb, and [sup 207]Pb. Additionally, the decay of Po-isotopes from deuteron irradiation of natural bismuth ([sup 209]Bi) was exploited for radiobismuth production. [sup 205]Bi was produced from [sup 206]Pb at 20 MeV with only 2% of [sup 206]Bi at 4 weeks post irradiation. Bismuth compounds as used in the treatment of peptic ulcer were labeled with [sup 205]Bi for absorption studies in animals and subjects. (Author).

  17. Production of Thorium-229 at the ORNL High Flux Isotope Reactor

    International Nuclear Information System (INIS)

    Boll, Rose Ann; Garland, Marc A.; Mirzadeh, Saed

    2008-01-01

    The investigation of targeted cancer therapy using -emitters has developed considerably in recent years and clinical trials have generated promising results. In particular, the initial clinical trials for treatment of acute myeloid leukemia have demonstrated the effectiveness of the -emitter 213Bi in killing cancer cells. Pre-clinical studies have also shown the potential application of both 213Bi and its 225Ac parent radionuclide in a variety of cancer systems and targeted radiotherapy. Bismuth-213 is obtained from a radionuclide generator system from decay of the 10-d 225Ac parent, a member of the 7340-y 229Th chain. Currently, 233U is the only viable source for high purity 229Th; however, due to increasing difficulties associated with 233U safeguards, processing additional 233U is presently unfeasible. The recent decision to downblend and dispose of enriched 233U further diminished the prospects for extracting 229Th from 233U stock. Nevertheless, the anticipated growth in demand for 225Ac may soon exceed the levels of 229Th (∼40 g or ∼8 Ci; ∼80 times the current ORNL 229Th stock) present in the aged 233U stockpile. The alternative routes for the production of 229Th, 225Ra and 225Ac include both reactor and accelerator approaches. Here, we describe production of 229Th via neutron transmutation of 226Ra targets in the ORNL High Flux Isotope Reactor (HFIR).

  18. Constructing narratives of heroism and villainy: case study of Myriad's BRACAnalysis(®) compared to Genentech's Herceptin(®).

    Science.gov (United States)

    Baldwin, A Lane; Cook-Deegan, Robert

    2013-01-01

    The development of Herceptin(®) is welcomed as a major advance in breast cancer treatment, while Myriad's development of BRACAnalysis(®) is a widely used diagnostic. However useful and successful this product is, its presence in the public eye is tainted by predominantly negative press about gene patenting and business practices. While retrospection invites a sharp contrast between Genentech's triumphal narrative of scientific achievement and Myriad's public image as a controversial monopolist, a comparative history of these companies' products reveals two striking consistencies: patents and public discontent. Despite these similarities, time has reduced the narrative to that of hero versus villain: Genentech is lauded - at least for the final outcome of the Herceptin(®) story - as a corporate good citizen, Myriad as a ruthless mercenary. Since patents undergird both products yet the narratives are so different, the stories raise the question: why have patents taken the fall as the scapegoat in current biotechnology policy debate? A widely publicized lawsuit and accompanying bad press have cast Myriad as a villain in the evolving narrative of biotechnology. While the lawsuit suggests that this villainy is attributable to Myriad's intellectual property, we suggest through a comparative case study that, at least in the Myriad case, it is not simply about the patents but also other business strategies the company chose to pursue. Patents were a necessary but not sufficient cause of controversy.

  19. Thermodynamics of Bi2O3-SiO2 system

    Directory of Open Access Journals (Sweden)

    Onderka B.

    2017-01-01

    Full Text Available Thermodynamic properties of the liquid Bi2O3-SiO2 solutions were determined from the results of the electrochemical measurements by use of the solid oxide galvanic cells with YSZ (Yttria-Stabilized-Zirconia electrolyte. Activities of Bi2O3 in the solutions were determined for 0.2, 0.3, 0.4, and 0.5 SiO2 mole fractions in the temperature range 1073-1293 K from measured electromotive force (e.m.f of the solid electrolyte galvanic cell: Bi, Bi2O3-SiO2 | YSZ | air (pO2 = 0.213 bar Additionally, heat capacity data obtained for two solid phases 6Bi2O3•SiO2 and 2Bi2O3•3SiO2 were included into optimization of thermodynamic properties of the system. Optimization procedure was supported by differential thermal analysis (DTA data obtained in this work as well as those accepted from the literature. Using the data obtained in this work, and the information about phase equilibria found in the literature, binary system Bi2O3-SiO2 was assessed with the ThermoCalc software.

  20. Effects of PEG tethering chain length of vitamin E TPGS with a Herceptin-functionalized nanoparticle formulation for targeted delivery of anticancer drugs.

    Science.gov (United States)

    Zhao, Jing; Feng, Si-Shen

    2014-03-01

    Drug formulation by ligand conjugated nanoparticles of biodegradable polymers has become one of the most important strategies in drug targeting. We have developed in our previous work nanoparticles of a mixture of two vitamin E TPGS based copolymers PLA-TPGS and TPGS-TOOH with the latter for Herceptin conjugation for targeted delivery of anticancer drugs such as docetaxel to the cancer cells of human epidermal growth factor receptor 2 (HER2) overexpression. In this research, we investigated the effects of the PEG chain length in TPGS, which is in fact a PEGylated vitamin E, on the cellular uptake and cytotoxicity of the drug formulated in the Herceptin-conjugated nanoparticles of PLA-TPGS/TPGS-COOH blend (NPs). Such NPs of PEG1000, PEG2000, PEG3350 and PEG5000, i.e. the PEG of molecule weight 1000, 2000, 3350 and 5000, were prepared by the nanoprecipitation method and characterized for their size and size distribution, drug loading, surface morphology, surface charge and surface chemistry as well as in vitro drug release profile, cellular uptake and cytotoxicity. We found among such nanoparticles, those of PEG1000, i.e. of the shortest PEG tethering chain length, could result in the best therapeutic effects, which are 24.1%, 37.3%, 38.1% more efficient in cellular uptake and 68.1%, 90%, 92.6% lower in IC50 (thus higher in cytotoxicity) than the Herceptin-conjugated nanoparticles of PLA-TPGS/TPGS-COOH blend of PEG2000, PEG3350 and PEG5000 respectively in treatment of SK-BR-3 cancer cells which are of high HER2 overexpression. We provided a theoretical explanation from surface mechanics and thermodynamics for endocytosis of nanoparticles. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. ¹¹¹In-Bn-DTPA-nimotuzumab with/without modification with nuclear translocation sequence (NLS) peptides: an Auger electron-emitting radioimmunotherapeutic agent for EGFR-positive and trastuzumab (Herceptin)-resistant breast cancer.

    Science.gov (United States)

    Fasih, Aisha; Fonge, Humphrey; Cai, Zhongli; Leyton, Jeffrey V; Tikhomirov, Ilia; Done, Susan J; Reilly, Raymond M

    2012-08-01

    Increased expression of epidermal growth factor receptors (EGFR) in breast cancer (BC) is often associated with trastuzumab (Herceptin)-resistant forms of the disease and represents an attractive target for novel therapies. Nimotuzumab is a humanized IgG(1) monoclonal antibody that is in clinical trials for treatment of EGFR-overexpressing malignancies. We show here that nimotuzumab derivatized with benzylisothiocyanate diethylenetriaminepentaacetic acid for labelling with the subcellular range Auger electron-emitter, (111)In and modified with nuclear translocation sequence (NLS) peptides ((111)In-NLS-Bn-DTPA-nimotuzumab) was bound, internalized and transported to the nucleus of EGFR-positive BC cells. Emission of Auger electrons in close proximity to the nucleus caused multiple DNA double-strand breaks which diminished the clonogenic survival (CS) of MDA-MB-468 cells that have high EGFR density (2.4 × 10(6) receptors/cell) to less than 3 %. (111)In-Bn-DTPA-nimotuzumab without NLS peptide modification was sevenfold less effective for killing MDA-MB-468 cells. (111)In-Bn-DTPA-nimotuzumab with/without NLS peptide modification were equivalently cytotoxic to MDA-MB-231 and TrR1 BC cells that have moderate EGFR density (5.4 × 10(5) or 4.2 × 10(5) receptors/cell, respectively) reducing their CS by twofold. MDA-MB-231 cells have intrinsic trastuzumab resistance due to low HER2 density, whereas TrR1 cells have acquired resistance despite HER2 overexpression. Biodistribution and microSPECT/CT imaging revealed that (111)In-NLS-Bn-DTPA-nimotuzumab exhibited more rapid elimination from the blood and lower tumour uptake than (111)In-Bn-DTPA-nimotuzumab. Tumour uptake of the radioimmunoconjugates in mice with MDA-MB-468 xenografts was high (8-16 % injected dose/g) and was blocked by administration of an excess of unlabelled nimotuzumab, demonstrating EGFR specificity. We conclude that (111)In-Bn-DTPA-nimotuzumab with/without NLS peptide modification are promising Auger

  2. Associations between the uptake of {sup 111}In-DTPA-trastuzumab, HER2 density and response to trastuzumab (Herceptin) in athymic mice bearing subcutaneous human tumour xenografts

    Energy Technology Data Exchange (ETDEWEB)

    McLarty, Kristin; Cornelissen, Bart; Scollard, Deborah A. [University of Toronto, Department of Pharmaceutical Sciences, Toronto, ON (Canada); Done, Susan J. [University of Toronto, Department of Medical Biophysics, Toronto, ON (Canada)]|[University of Toronto, Department of Laboratory Medicine and Pathobiology, Toronto, ON (Canada)]|[University Health Network, Department of Pathology, Toronto, ON (Canada); Chun, Kathy [North York General Hospital, Genetics Program, Toronto, ON (Canada); Reilly, Raymond M. [University of Toronto, Department of Pharmaceutical Sciences, Toronto, ON (Canada)]|[University of Toronto, Department of Medical Imaging, Toronto, ON (Canada)]|[University Health Network, Toronto General Research Institute, Toronto, ON (Canada)]|[University of Toronto, Leslie Dan Faculty of Pharmacy, Toronto, ON (Canada)

    2009-01-15

    The purpose of the study was to investigate the associations between uptake of {sup 111}In-DTPA-trastuzumab, tumour HER2 density and response to trastuzumab (Herceptin) of human breast cancer (BC) xenografts in athymic mice. The tumour uptake of {sup 111}In-DTPA-trastuzumab in athymic mice bearing BC xenografts with increasing HER2 density (0 to 3+) was evaluated. Specific uptake ratios were established in biodistribution (SUR) and imaging studies (ROI-SUR) using {sup 111}In-labeled mouse IgG ({sup 111}In-DTPA-mIgG). Further corrections were made for circulating radioactivity using tumour-to-blood ratios defined as a localization index (LI) and region-of-interest localization index (ROI-LI), respectively. Mice were treated with trastuzumab (Herceptin). A tumour growth inhibition index (TGI) was calculated and relative TGIs calculated by dividing the TGI of control by that of trastuzumab-treated mice. Strong, nonlinear associations with HER2 density were obtained if the uptake of {sup 111}In-DTPA-trastuzumab was corrected for nonspecific IgG localization (i.e., SUR; r{sup 2}=0.99) and circulating radioactivity (i.e., LI; r{sup 2} =0.87), but without these corrections, the association between HER2 density and tumour uptake was poor (r{sup 2}=0.22). There was a strong association between ROI-SUR and ROI-LI values and HER2 expression (r{sup 2}=0.90 and r{sup 2}=0.95), respectively. All tumours were imaged. Relative TGI values were associated with increasing uncorrected tumour uptake of {sup 111}In-DTPA-trastuzumab but not always with HER2 density (i.e., MCF-HER2-18 cells with trastuzumab-resistance). HER2 expression (0 to 3+) can be differentiated using {sup 111}In-DTPA-trastuzumab, but requires correction of tumour uptake for nonspecific IgG localization and circulating radioactivity. The uncorrected uptake of {sup 111}In-DTPA-trastuzumab was associated with tumour response to trastuzumab. (orig.)

  3. Low-emittance Storage Rings

    CERN Document Server

    Wolski, Andrzej

    2014-01-01

    The effects of synchrotron radiation on particle motion in storage rings are discussed. In the absence of radiation, particle motion is symplectic, and the beam emittances are conserved. The inclusion of radiation effects in a classical approximation leads to emittance damping: expressions for the damping times are derived. Then, it is shown that quantum radiation effects lead to excitation of the beam emittances. General expressions for the equilibrium longitudinal and horizontal (natural) emittances are derived. The impact of lattice design on the natural emittance is discussed, with particular attention to the special cases of FODO-, achromat- and theoretical-minimum-emittance-style lattices. Finally, the effects of betatron coupling and vertical dispersion (generated by magnet alignment and lattice tuning errors) on the vertical emittance are considered.

  4. Therapy with high LET Radioisotopes: Can sufficient levels of attractive Auger and alpha emitters be produced to make their use practical?

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; Mirzadeh, S.; Stabin, M.; Brill, A.B.

    2005-01-01

    Because of localized energy deposition within a very small volume, cellular targeted therapy with high linear energy transfer (LET) Auger-electron and alpha-particle emitting radioisotopes is of great interest. While the energy deposition from alpha particles usually encompasses several cell diameters, the dose from Auger electrons is confined to a single cell. Two major challenges for broader use of Alpha and Auger emitters are the efficient and cost effective routine production of sufficient levels of these radioisotopes, and the availability of targeting molecules to which the radioisotopes can be attached for cellular delivery of sufficient levels of activity for effective therapy. Examples of several Alpha-and Auger-emitting radioisotopes of current interest are presented. Alpha- and Auger electron-emitting radioisotopes can be produced in accelerators (A) and nuclear reactors (R), and several alpha emitter congeners (i.e. thorium-229) can be obtained from uranium decay products. The challenge for reactor production, is the availability and exploitation of methods - other then the usual radiative (n,γ) production route which will provide no-carrier-added (nca) or the high specific activity radioisotopes of interest. The submitted manuscript has been authored by a contractor of the U.S. Government under contract DE-AC05-00OR22725. Accordingly, the U.S. Government retains a nonexclusive, royalty-free license to publish or reproduce the published form of this contribution, or allow others to do so, for U.S. Government purposes High LET radioisotopes of current interest which are in the initial stages of development and/or which demonstrate practical use in clinical trials include several alpha-emitters, in particular bismuth-213 - and also the actinium-225 parent - astatine-211 and bismuth-212. Extensive experimental studies have been reported with Auger iododeoxyuridine (IdUR) radiolabeled with the iodine-125 emitter-labeled. However, development of production

  5. Rare Earth Garnet Selective Emitter

    Science.gov (United States)

    Lowe, Roland A.; Chubb, Donald L.; Farmer, Serene C.; Good, Brian S.

    1994-01-01

    Thin film Ho-YAG and Er-YAG emitters with a platinum substrate exhibit high spectral emittance in the emission band (epsilon(sub lambda) approx. = 0.75, sup 4)|(sub 15/2) - (sup 4)|(sub 13/2),for Er-YAG and epsilon(sub lambda) approx. = 0.65, (sup 5)|(sub 7) - (sup 5)|(sub 8) for Ho-YAG) at 1500 K. In addition, low out-of-band spectral emittance, epsilon(sub lambda) less than 0.2, suggest these materials would be excellent candidates for high efficiency selective emitters in thermophotovoltaic (TPV) systems operating at moderate temperatures (1200-1500 K). Spectral emittance measurements of the thin films were made (1.2 less than lambda less than 3.0 microns) and compared to the theoretical emittances calculated using measured values of the spectral extinction coefficient. In this paper we present the results for a new class of rare earth ion selective emitters. These emitters are thin sections (less than 1 mm) of yttrium aluminum garnet (YAG) single crystal with a rare earth substitutional impurity. Selective emitters in the near IR are of special interest for thermophotovoltaic (TPV) energy conversion. The most promising solid selective emitters for use in a TPV system are rare earth oxides. Early spectral emittance work on rare earth oxides showed strong emission bands in the infrared (0.9 - 3 microns). However, the emittance outside the emission band was also significant and the efficiency of these emitters was low. Recent improvements in efficiency have been made with emitters fabricated from fine (5 - 10 microns) rare earth oxide fibers similar to the Welsbach mantle used in gas lanterns. However, the rare earth garnet emitters are more rugged than the mantle type emitters. A thin film selective emitter on a low emissivity substrate such as gold, platinum etc., is rugged and easily adapted to a wide variety of thermal sources. The garnet structure and its many subgroups have been successfully used as hosts for rare earth ions, introduced as substitutional

  6. Bismuth absorption from sup 205 Bi-labelled pharmaceutical bismuth compounds used in the treatment of peptic ulcer disease

    Energy Technology Data Exchange (ETDEWEB)

    Dresow, B.; Fischer, R.; Gabbe, E.E.; Wendel, J.; Heinrich, H.C. (Eppendorf University Hospital, Hamburg (Germany))

    1992-04-01

    The absorption of bismuth from five {sup 205}Bi-labelled pharmaceutically used bismuth compounds was studied in man. From single oral doses of all compounds under investigation only <0.1% bismuth was absorbed and excreted with the urine. A significantly higher absorption was observed from the colloidal bismuth subcitrate and the basic bismuth gallate than from the basic bismuth salicylate, nitrate and aluminate. No retention of bismuth in the whole body was found from the single dose experiment. The biologic fast-term half-lives of absorbed bismuth were calculated to be 0.12 and 1.5 days. 14 refs., 2 figs., 1 tab.

  7. A kit to prepare {sup 111}In-DTPA-trastuzumab (Herceptin) Fab fragments injection under GMP conditions for imaging or radioimmunoguided surgery of HER2-positive breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Scollard, Deborah A.; Chan, Conrad [Department of Pharmaceutical Sciences, University of Toronto, Toronto, ON, M5S 3M2 (Canada); Holloway, Claire M.B. [Department of Surgery, Sunnybrook Health Sciences Centre, Toronto, ON, M4N 1H1 (Canada); Reilly, Raymond M., E-mail: raymond.reilly@utoronto.c [Department of Pharmaceutical Sciences, University of Toronto, Toronto, ON, M5S 3M2 (Canada); Department of Medical Imaging, University of Toronto, Toronto, ON, M5S 3E2 (Canada); Toronto General Research Institute, University Health Network, Toronto, ON, M5G 2M9 (Canada)

    2011-01-15

    Introduction: The human epidermal growth factor receptor-2 (HER2) gene is amplified in 25% of invasive breast cancers, and receptor overexpression has been noted in up to 60% of early stages of the disease [ductal carcinoma in situ (DCIS)]. Preclinical studies have revealed high tumor/blood ratios (>27:1) for {sup 111}In-labeled Fab fragments of the HER2 monoclonal antibody, trastuzumab (Herceptin) ({sup 111}In-DTPA-trastuzumab Fab) at 72 h pi in athymic mice bearing subcutaneous human breast cancer xenografts. Our aim in this study was to formulate a kit for preparation of {sup 111}In-DTPA-trastuzumab Fab injection under good manufacturing practice (GMP) conditions suitable for human administration in a Phase I clinical trial of imaging and radioimmunoguided surgery (RIGS) of HER2-positive breast cancer. Methods: Fab fragments were produced by digestion of trastuzumab IgG (Herceptin) with immobilized papain for 20 h at 37{sup o}C. Fab fragments were purified by ultrafiltration, then reacted with a 10-fold molar excess of diethylenetriaminepentaacetic acid (DTPA) dianhydride. DTPA-Fab fragments were purified, then sterilized by filtration into unit dose glass vials (kits). Kits were tested against specifications for volume (0.9-1.1 ml), protein concentration (0.45-0.55 mg/ml), pH (5.5-6.5), DTPA substitution (0.5-4.0 mol DTPA/mol Fab), appearance (clear, colorless and particle free), labeling efficiency ({>=}85%), and sterility and apyrogenicity (USP XXXII). Immunoreactivity of {sup 111}In-DTPA-trastuzumab Fab towards HER2 was measured by saturation radioligand binding assays using SKBR-3 human breast cancer cells (specifications: K{sub a}=0.6-9.6x10{sup 7} L/mol; B{sub max}=0.6-10.4x10{sup 6} sites/cell). {sup 111}In-DTPA-trastuzumab Fab injection was prepared by adding 80-100 MBq of {sup 111}InCl{sub 3} to a single kit vial and incubating for 30 min at room temperature. {sup 111}In-DTPA-trastuzumab Fab was assayed for the amount of radioactivity and tested for p

  8. In vivo examination of {sup 188}Re(I)-tricarbonyl-labeled trastuzumab to target HER2-overexpressing breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chen, K.-T. [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Lee, T.-W. [Institute of Nuclear Energy Research, Longtan 32546, Taiwan (China); Lo, Jem-Mau [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Institute of Nuclear Engineering and Science, National Tsing Hua University, Hsinchu 30013, Taiwan (China)], E-mail: jmlo@mx.nthu.edu.tw

    2009-05-15

    Introduction: Trastuzumab (Herceptin), a humanized IgG1 monoclonal antibody directed against the extracellular domain of the HER2 protein, acts as an immunotherapeutic agent for HER2-overexpressing human breast cancers. Radiolabeled trastuzumab with {beta}- or {alpha} emitters can be used as radioimmunotherapeutic agent for the similar purpose but with additional radiation effect. Methods: In this study, trastuzumab was labeled with {sup 188}Re for radioimmunotherapy of HER2/neu-positive breast cancer. {sup 188}Re(I)-tricarbonyl ion, [{sup 188}Re(OH{sub 2}){sub 3}(CO){sub 3}]{sup +}, was employed as a precursor for directly labeling the monoclonal antibody with {sup 188}Re. The immunoreactivity of {sup 188}Re(I)-trastuzumab was estimated by competition receptor-binding assay using HER2/neu-overexpressive BT-474 human breast cancer cells. The localization properties of {sup 188}Re(I)-trastuzumab within both tumor and normal tissues of athymic mice bearing BT-474 human breast cancer xenografts (HER2/neu-overexpressive) and similar mice bearing MCF-7 human breast cancer xenografts (HER2/neu-low expressive) were investigated. Results: When incubated with human serum albumin and histidine at 25{sup o}C, {sup 188}Re(I)-trastuzumab was found to be stable within 24 h. The IC{sub 50} of {sup 188}Re(I)-trastuzumab was found to be 22.63{+-}4.57 nM. {sup 188}Re(I)-trastuzumab was shown to accumulate specifically in BT-474 tumor tissue in in vivo biodistribution studies. By microSPECT/CT, the image of {sup 188}Re localized BT-474 tumor was clearly visualized within 24 h. In contrast, {sup 188}Re(I)-trastuzumab uptake in HER2-low-expressing MCF-7 tumor was minimal, and the {sup 188}Re image at the localization of the tumor was dim. Conclusion: These results reveal that {sup 188}Re(I)-trastuzumab could be an appropriate radioimmunotherapeutic agent for the treatment of HER2/neu-overexpressing cancers.

  9. Shielding in ungated field emitter arrays

    Energy Technology Data Exchange (ETDEWEB)

    Harris, J. R. [U.S. Navy Reserve, Navy Operational Support Center New Orleans, New Orleans, Louisiana 70143 (United States); Jensen, K. L. [Code 6854, Naval Research Laboratory, Washington, D.C. 20375 (United States); Shiffler, D. A. [Directed Energy Directorate, Air Force Research Laboratory, Albuquerque, New Mexico 87117 (United States); Petillo, J. J. [Leidos, Billerica, Massachusetts 01821 (United States)

    2015-05-18

    Cathodes consisting of arrays of high aspect ratio field emitters are of great interest as sources of electron beams for vacuum electronic devices. The desire for high currents and current densities drives the cathode designer towards a denser array, but for ungated emitters, denser arrays also lead to increased shielding, in which the field enhancement factor β of each emitter is reduced due to the presence of the other emitters in the array. To facilitate the study of these arrays, we have developed a method for modeling high aspect ratio emitters using tapered dipole line charges. This method can be used to investigate proximity effects from similar emitters an arbitrary distance away and is much less computationally demanding than competing simulation approaches. Here, we introduce this method and use it to study shielding as a function of array geometry. Emitters with aspect ratios of 10{sup 2}–10{sup 4} are modeled, and the shielding-induced reduction in β is considered as a function of tip-to-tip spacing for emitter pairs and for large arrays with triangular and square unit cells. Shielding is found to be negligible when the emitter spacing is greater than the emitter height for the two-emitter array, or about 2.5 times the emitter height in the large arrays, in agreement with previously published results. Because the onset of shielding occurs at virtually the same emitter spacing in the square and triangular arrays, the triangular array is preferred for its higher emitter density at a given emitter spacing. The primary contribution to shielding in large arrays is found to come from emitters within a distance of three times the unit cell spacing for both square and triangular arrays.

  10. 15 CFR 904.213 - Settlements.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 3 2010-01-01 2010-01-01 false Settlements. 904.213 Section 904.213 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) NATIONAL OCEANIC... and Appeal Procedures General § 904.213 Settlements. If settlement is reached before the Judge has...

  11. 14 CFR 16.213 - Discovery.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Discovery. 16.213 Section 16.213... PRACTICE FOR FEDERALLY-ASSISTED AIRPORT ENFORCEMENT PROCEEDINGS Hearings § 16.213 Discovery. (a) Discovery... discovery permitted by this section if a party shows that— (1) The information requested is cumulative or...

  12. 22 CFR 213.2 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... garnishment means the process by which federal agencies require a private sector employer to withhold up to 15... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Definitions. 213.2 Section 213.2 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT CLAIMS COLLECTION General § 213.2 Definitions. (a...

  13. Bi-layer non-doped small-molecular white organic light-emitting diodes with high colour stability

    International Nuclear Information System (INIS)

    Chen Shuming; Kwok, Hoi-Sing; Zhao Zujin; Tang Benzhong; Wang Zhiming; Lu Ping; Gao Zhao; Ma Yuguang

    2011-01-01

    Bi-layer non-doped white organic light-emitting diodes (WOLEDs) with hole-transporting layer 4-(4-(1,2,2-triphenylvinyl)phenyl)-7-(5-(4-(1,2,2-triphenylvinyl)phenyl) thiophen-2yl)benzo[c][1,2,5]thiadiazole (BTPETTD) as a red emitter and electron-transporting layer 4,4'-bis(1-phenyl-1H-phenanthro[9,10-d]imidazol-2-yl)biphenyl (DDPi) as a blue emitter are demonstrated. The blue emission is due to direct recombination of excitons in DPPi, while the red emission originates not only from the direct recombination of excitons in BTPETTD but also from a colour down-conversion process by absorbing blue emission and re-emitting red photons. The combination of blue emission and red emission yields an efficient and extremely stable white colour, regardless of driving voltages. In our demonstration, a bi-layer WOLED with an efficiency of 4.2 cd A -1 at 1000 cd m -2 , 1931 Commision International de L'Eclairage coordinates of (0.31, 0.31) and a high colour rendering index of 92 over a wide range of driving voltages is obtained.

  14. 50 CFR 21.3 - Definitions.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Definitions. 21.3 Section 21.3 Wildlife... (CONTINUED) MIGRATORY BIRD PERMITS Introduction § 21.3 Definitions. In addition to definitions contained in... environment that is intensively manipulated by man for the purpose of producing raptors of selected species...

  15. 14 CFR 171.213 - Reports.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Reports. 171.213 Section 171.213... FACILITIES NON-FEDERAL NAVIGATION FACILITIES VHF Marker Beacons § 171.213 Reports. The owner of each facility to which this subpart applies shall make the following reports, at the times indicated, to the...

  16. 27 CFR 28.213 - [Reserved

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false [Reserved] 28.213 Section 28.213 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS EXPORTATION OF ALCOHOL Exportation of Wine With Benefit of Drawback § 28.213...

  17. 1.142 mu m GaAsBi/GaAs Quantum Well Lasers Grown by Molecular Beam Epitaxy

    DEFF Research Database (Denmark)

    Wu, Xiaoyan; Pan, Wenwu; Zhang, Zhenpu

    2017-01-01

    in GaAsBi0.058/GaAs quantum well LDs grown by molecular beam epitaxy. The output power is up to 127 mW at 300 K under pulsed mode. We also demonstrate continuous wave mode operation up to 273 K for the first time. The temperature coefficient of the GaAsBi/GaAs LD is 0.26 nm/K in the temperature range......As a promising new class of near-infrared light emitters, GaAsBi laser diodes (LDs) are considered to have a high energy efficiency and an insensitive temperature dependence of the band gap. In this paper, we realize the longest ever reported lasing wavelength up to 1.142 mu m at room temperature...

  18. An analytical model to calculate absorbed fractions for internal dosimetry with alpha, beta and gamma emitters

    Directory of Open Access Journals (Sweden)

    Ernesto Amato

    2014-03-01

    Full Text Available We developed a general model for the calculation of absorbed fractions in ellipsoidal volumes of soft tissue uniformly filled with alpha, beta and gamma emitting radionuclides. The approach exploited Monte Carlo simulations with the Geant4 code to determine absorbed fractions in ellipsoids characterized by a wide range of dimensions and ellipticities, for monoenergetic emissions of each radiation type. The so-obtained absorbed fractions were put in an analytical relationship with the 'generalized radius', calculated as 3V/S, where V is the ellipsoid volume and S its surface. Radiation-specific parametric functions were obtained in order to calculate the absorbed fraction of a given radiation in a generic ellipsoidal volume. The dose from a generic radionuclide can be calculated through a process of summation and integration over the whole radionuclide emission spectrum, profitably implemented in an electronic spreadsheet. We compared the results of our analytical calculation approach with those obtained from the OLINDA/EXM computer software, finding a good agreement in a wide range of sphere radii, for the high-energy pure beta emitter 90Y, the commonly employed beta-gamma emitter 131I, and the pure alpha emitter 213Po. The generality of our approach makes it useful an easy to implement in clinical dosimetry calculations as well as in radiation safety estimations when doses from internal radionuclide uptake are to be taken into account.

  19. 13 CFR 134.213 - Discovery.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Discovery. 134.213 Section 134.213... OFFICE OF HEARINGS AND APPEALS Rules of Practice for Most Cases § 134.213 Discovery. (a) Motion. A party may obtain discovery only upon motion, and for good cause shown. (b) Forms. The forms of discovery...

  20. 28 CFR 21.3 - Aliens.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Aliens. 21.3 Section 21.3 Judicial Administration DEPARTMENT OF JUSTICE WITNESS FEES § 21.3 Aliens. (a) Aliens entitled to payment of $30 per day. The following aliens are entitled to witness fees and allowances provided in § 21.4: (1) Aliens...

  1. 36 CFR 2.13 - Fires.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Fires. 2.13 Section 2.13... PROTECTION, PUBLIC USE AND RECREATION § 2.13 Fires. (a) The following are prohibited: (1) Lighting or maintaining a fire, except in designated areas or receptacles and under conditions that may be established by...

  2. Radiation dosimetry in radiotherapy with internal emitters

    International Nuclear Information System (INIS)

    Stabin, Michael G.

    1997-01-01

    Full text. Radiation dosimetry radionuclides are currently being labeled to various biological agents used in internal emitter radiotherapy. This talk will review the various technologies and types of radiolabel in current use, with focus on the characterization of the radiation dose to the various important tissues of the body. Methods for obtaining data, developing kinetic models, and calculating radiation doses will be reviewed. Monoclonal antibodies are currently being labeled with both alpha and beta emitting radionuclides in attempts to find effective agents against cancer. Several radionuclides are also being used as bone pain palliation agents. These agents must be studied in clinical trials to determine the biokinetics and radiation dosimetry prior to approval for general use. In such studies, it is important to ensure the collection of the appropriate kinds of data and to collect the data at appropriate time intervals. The uptake and retention of activity in all significant source organs and in excreta be measured periodically (with at least 2 data points phase of uptake or clearance). Then, correct dosimetry methods must be applied - the best available methods for characterizing the radionuclide kinetic and for estimating the dosimetry in the various organs of the body especially the marrow, should be used. Attempts are also under way to develop methods for estimating true patient-specific dosimetry. Cellular and animal studies are also. Valuable in evaluating the efficacy of the agents in shrinking or eliminating tumors; some results from such studies will also be discussed. The estimation of radiation doses to patients in therapy with internal emitters involves several complex phases of analysis. Careful attention to detail and the use of the best available methods are essential to the protection of the patient and a successful outcome

  3. Monolithic multinozzle emitters for nanoelectrospray mass spectrometry

    Science.gov (United States)

    Wang, Daojing [Daly City, CA; Yang, Peidong [Kensington, CA; Kim, Woong [Seoul, KR; Fan, Rong [Pasadena, CA

    2011-09-20

    Novel and significantly simplified procedures for fabrication of fully integrated nanoelectrospray emitters have been described. For nanofabricated monolithic multinozzle emitters (NM.sup.2 emitters), a bottom up approach using silicon nanowires on a silicon sliver is used. For microfabricated monolithic multinozzle emitters (M.sup.3 emitters), a top down approach using MEMS techniques on silicon wafers is used. The emitters have performance comparable to that of commercially-available silica capillary emitters for nanoelectrospray mass spectrometry.

  4. 12 CFR 213.7 - Advertising.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 2 2010-01-01 2010-01-01 false Advertising. 213.7 Section 213.7 Banks and... (REGULATION M) § 213.7 Advertising. (a) General rule. An advertisement for a consumer lease may state that a... paragraph (d)(1) of this section shall also state the following items: (i) That the transaction advertised...

  5. Real-time radionuclide identification in γ-emitter mixtures based on spiking neural network

    International Nuclear Information System (INIS)

    Bobin, C.; Bichler, O.; Lourenço, V.; Thiam, C.; Thévenin, M.

    2016-01-01

    Portal radiation monitors dedicated to the prevention of illegal traffic of nuclear materials at international borders need to deliver as fast as possible a radionuclide identification of a potential radiological threat. Spectrometry techniques applied to identify the radionuclides contributing to γ-emitter mixtures are usually performed using off-line spectrum analysis. As an alternative to these usual methods, a real-time processing based on an artificial neural network and Bayes’ rule is proposed for fast radionuclide identification. The validation of this real-time approach was carried out using γ-emitter spectra ( 241 Am, 133 Ba, 207 Bi, 60 Co, 137 Cs) obtained with a high-efficiency well-type NaI(Tl). The first tests showed that the proposed algorithm enables a fast identification of each γ-emitting radionuclide using the information given by the whole spectrum. Based on an iterative process, the on-line analysis only needs low-statistics spectra without energy calibration to identify the nature of a radiological threat. - Highlights: • A fast radionuclide identification algorithm applicable in spectroscopic portal monitors is presented. • The proposed algorithm combines a Bayesian sequential approach and a spiking neural network. • The algorithm was validated using the mixture of γ-emitter spectra provided by a well-type NaI(Tl) detector. • The radionuclide identification process is implemented using the whole γ-spectrum without energy calibration.

  6. Trastuzumab (Herceptin)-associated cardiomyopathy presented as new onset of complete left bundle-branch block mimicking acute coronary syndrome: a case report and literature review.

    Science.gov (United States)

    Tu, Chung-Ming; Chu, Kai-Ming; Yang, Shin-Ping; Cheng, Shu-Mung; Wang, Wen-Been

    2009-09-01

    Trastuzumab (Herceptin) is well documented in reducing suffering and mortality from breast cancer. The clinically most important side effect of Herceptin is cardiotoxicity, which is reported in 2.6% to 4.5% of patients receiving trastuzumab alone and in as many as 27% of patients when trastuzumab is combined with an anthracycline in metastatic disease. We reported the case of a 50-year-old woman who presented to our emergency department (ED) because of chest pain and shortness of breath. On physical examination, holosystolic murmur over apex could be heard. Pulmonary and abdominal examinations were unremarkable. Twelve-lead electrocardiography showed sinus tachycardia and new onset of complete left bundle-branch block. Emergent transthoracic echocardiography revealed generalized hypokinesia of left ventricle and akinesia over interventricular septum and apex. She subsequently underwent immediate coronary angiography that revealed normal coronary angiography, and left ventriculogram revealed generalized hypokinesia with severe left ventricle dysfunction with ejection fraction of 33%. During right heart catheterization and endomyocardial biopsy, cardiac tamponade developed and was successfully relieved by pericardial window. She was discharged event-free 3 weeks later with conservative treatment. Although new onset of complete left bundle-branch block in a patient with chest pain may be acute coronary syndrome, careful review of medicine history is mandatory to avoid unnecessary procedure and complications.

  7. Alpha particles induce expression of immunogenic markers on tumour cells

    International Nuclear Information System (INIS)

    Gorin, J.B.; Gouard, S.; Cherel, M.; Davodeau, F.; Gaschet, J.; Morgenstern, A.; Bruchertseifer, F.

    2013-01-01

    The full text of the publication follows. Radioimmunotherapy (RIT) is an approach aiming at targeting the radioelements to tumours, usually through the use of antibodies specific for tumour antigens. The radiations emitted by the radioelements then induce direct killing of the targeted cells as well as indirect killing through bystander effect. Interestingly, it has been shown that ionizing radiations, in some settings of external radiotherapy, can foster an immune response directed against tumour cells. Our research team is dedicated to the development of alpha RIT, i.e RIT using alpha particle emitters, we therefore decided to study the effects of such particles on tumour cells in regards to their immunogenicity. First, we studied the effects of bismuth 213, an alpha emitter, on cellular death and autophagy in six different tumour cell lines. Then, we measured the expression of 'danger' signals and MHC molecules at the cell surface to determine whether irradiation with 213 Bi could cause the tumour cells to be recognized by the immune system. Finally a co-culture of dendritic cells with irradiated tumour cells was performed to test whether it would induce dendritic cells to mature. No apoptosis was detected within 48 hours after irradiation in any cell line, however half of them exhibited signs of autophagy. No increase in membrane expression of 'danger' signals was observed after treatment with 213 Bi, but we showed an increase in expression of MHC class I and II for some cell lines. Moreover, the co-culture experiment indicated that the immunogenicity of a human adenocarcinoma cell line (LS 174T) was enhanced in vitro after irradiation with alpha rays. These preliminary data suggest that alpha particles could be of interest in raising an immune response associated to RIT. (authors)

  8. FACET Emittance Growth

    Energy Technology Data Exchange (ETDEWEB)

    Frederico, J; Hogan, M.J.; Nosochkov, Y.; Litos, M.D.; Raubenheimer, T.; /SLAC

    2011-04-05

    FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration. The FACET beamline consists of a chicane and final focus system to compress the 23 GeV, 3.2 nC electron bunches to {approx}20 {micro}m long and {approx}10 {micro}m wide. Simulations of the FACET beamline indicate the short-duration and large, 1.5% rms energy spread beams may suffer a factor of four emittance growth from a combination of chromaticity, incoherent synchrotron radiation (ISR), and coherent synchrotron radiation (CSR). Emittance growth is directly correlated to head erosion in plasma wakefield acceleration and is a limiting factor in single stage performance. Studies of the geometric, CSR, and ISR components are presented. Numerical calculation of the rms emittance can be overwhelmed by long tails in the simulated phase space distributions; more useful definitions of emittance are given. A complete simulation of the beamline is presented as well, which agrees with design specifications.

  9. FACET Emittance Growth

    International Nuclear Information System (INIS)

    Frederico, Joel

    2011-01-01

    FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration. The FACET beamline consists of a chicane and final focus system to compress the 23 GeV, 3.2 nC electron bunches to ∼20 (micro)m long and ∼10 (micro)m wide. Simulations of the FACET beamline indicate the short-duration and large, 1.5% rms energy spread beams may suffer a factor of four emittance growth from a combination of chromaticity, incoherent synchrotron radiation (ISR), and coherent synchrotron radiation (CSR). Emittance growth is directly correlated to head erosion in plasma wakefield acceleration and is a limiting factor in single stage performance. Studies of the geometric, CSR, and ISR components are presented. Numerical calculation of the rms emittance can be overwhelmed by long tails in the simulated phase space distributions; more useful definitions of emittance are given. A complete simulation of the beamline is presented as well, which agrees with design specifications.

  10. 49 CFR 213.2 - Preemptive effect.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Preemptive effect. 213.2 Section 213.2 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRACK SAFETY STANDARDS General § 213.2 Preemptive effect. Under 49 U.S.C. 20106...

  11. Development of radioactively labelled cancer seeking biomolecules for targeted radiotherapy

    International Nuclear Information System (INIS)

    Balter, H.; Verdera, S.

    2000-01-01

    The main objective of this project is the labelling and quality control of biomolecules with radionuclides beta emitters with high purity and stability. Techniques and methodology for labelling with 188 Re, 153 Sm, and 125 I as well as quality controls were done according the recommendations of the first research coordination meeting of this CRP. Also some useful chelators reported in the literature were synthesized in our laboratory

  12. Low emittance photoinjectors

    International Nuclear Information System (INIS)

    Ferrario, Massimo

    2001-01-01

    Photon colliders require high charge polarized electron beams with very low normalized emittances, possibly lower than the actual damping rings design goals. Recent analytical and numerical efforts in understanding beam dynamics in RF photoinjectors have raised again the question as to whether the performances of an RF electron gun based injector could be competitive with respect to a damping ring. As a matter of discussion we report in this paper the most recent results concerning low emittance photoinjector designs: the production of polarized electron beams by DC and/or RF guns is illustrated together with space charge compensation techniques and thermal emittance effects. New ideas concerning multi-gun injection system and generation of flat beams by RF gun are also discussed

  13. 29 CFR 780.213 - Produce business.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false Produce business. 780.213 Section 780.213 Labor Regulations... Specific Situations Hatchery Operations § 780.213 Produce business. In some instances, hatcheries also engage in the produce business as such and commingle with the culled eggs and chickens other eggs and...

  14. Volumetric spiral chemical shift imaging of hyperpolarized [2-(13) c]pyruvate in a rat c6 glioma model.

    Science.gov (United States)

    Park, Jae Mo; Josan, Sonal; Jang, Taichang; Merchant, Milton; Watkins, Ron; Hurd, Ralph E; Recht, Lawrence D; Mayer, Dirk; Spielman, Daniel M

    2016-03-01

    MRS of hyperpolarized [2-(13)C]pyruvate can be used to assess multiple metabolic pathways within mitochondria as the (13)C label is not lost with the conversion of pyruvate to acetyl-CoA. This study presents the first MR spectroscopic imaging of hyperpolarized [2-(13)C]pyruvate in glioma-bearing brain. Spiral chemical shift imaging with spectrally undersampling scheme (1042 Hz) and a hard-pulse excitation was exploited to simultaneously image [2-(13)C]pyruvate, [2-(13)C]lactate, and [5-(13)C]glutamate, the metabolites known to be produced in brain after an injection of hyperpolarized [2-(13)C]pyruvate, without chemical shift displacement artifacts. A separate undersampling scheme (890 Hz) was also used to image [1-(13)C]acetyl-carnitine. Healthy and C6 glioma-implanted rat brains were imaged at baseline and after dichloroacetate administration, a drug that modulates pyruvate dehydrogenase kinase activity. The baseline metabolite maps showed higher lactate and lower glutamate in tumor as compared to normal-appearing brain. Dichloroacetate led to an increase in glutamate in both tumor and normal-appearing brain. Dichloroacetate-induced %-decrease of lactate/glutamate was comparable to the lactate/bicarbonate decrease from hyperpolarized [1-(13)C]pyruvate studies. Acetyl-carnitine was observed in the muscle/fat tissue surrounding the brain. Robust volumetric imaging with hyperpolarized [2-(13)C]pyruvate and downstream products was performed in glioma-bearing rat brains, demonstrating changes in mitochondrial metabolism with dichloroacetate. © 2015 Wiley Periodicals, Inc.

  15. 46 CFR 108.213 - Heating requirements.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Heating requirements. 108.213 Section 108.213 Shipping... EQUIPMENT Construction and Arrangement Accommodation Spaces § 108.213 Heating requirements. (a) Each accommodation space must be heated by a heating system that can maintain at least 20°C. (68°F.). (b) Radiators...

  16. Comparative analysis of CD138 antigen targeting for the treatment of multiple myeloma with bismuth-213 and Melphalan chemotherapy

    International Nuclear Information System (INIS)

    Gouard, S.; Gaschet, J.; Maurel, C.; Barbet, J.; Davodeau, F.; Pallardy, A.; Faivre-Chauvet, A.; Kraeber-Bodere, F.; Bruchertseifer, F.; Morgenstern, A.; Cherel, M.

    2015-01-01

    Full text of publication follows. Aim: multiple myeloma (MM) is a B-cell malignancy of terminally differentiated plasma cells within the bone marrow, with the presence of a monoclonal immunoglobulin in serum and/or urine and development of osteolytic bone lesions in human. Despite intense research to develop new treatments, cure is almost never achieved. Alpha-radioimmunotherapy (RIT) has been shown to be effective in vivo in a multiple myeloma model and seems particularly suited for disseminated tumour cells or small clusters of tumour cells. CD138 (Syndecan-1) is found mainly in epithelial cells, but has been shown to be expressed by most myeloma cells, both in human and in mouse. In order to define where alpha RIT stands in MM treatment, the aim of this study was to compare Melphalan, MM standard treatment, with alpha RIT using a bismuth-213-labelled anti-mouse CD138 rat antibody in a syngeneic mouse MM model. Material and Methods: C57BL/KaLwRij mice were grafted with 10 6 5T33 cells (murine myeloma cells). Luciferase transfected 5T33 were used for in vivo localization of the cells during the course of disease. The first step of the study was to assess the dose-response of Melphalan (100, 200 et 300 μg/mouse), 21 days after engraftment. The second step consisted in therapeutic association: Melphalan followed by RIT at d22 et d25 after engraftment. Toxicity (animal weight, blood cell counts) and treatment efficacy were studied in animals receiving no treatment, injected with Melphalan alone (200 μg), RIT alone at d22 and d25 (3.7 MBq of 213 Bi-anti-CD138) and Melphalan combined with alpha RIT. Results: fifty percent of untreated mice died by d64 after MM engraftment. In mice treated with Melphalan alone, only the 200 μg dose improved median survival. No animal was cured after Melphalan treatment whereas 60% of the mice survived with RIT alone at d22 after tumour engraftment. However, the therapeutic window seems to be narrow, indeed no effect was observed with

  17. A Hierarchical multi-input and output Bi-GRU Model for Sentiment Analysis on Customer Reviews

    Science.gov (United States)

    Zhang, Liujie; Zhou, Yanquan; Duan, Xiuyu; Chen, Ruiqi

    2018-03-01

    Multi-label sentiment classification on customer reviews is a practical challenging task in Natural Language Processing. In this paper, we propose a hierarchical multi-input and output model based bi-directional recurrent neural network, which both considers the semantic and lexical information of emotional expression. Our model applies two independent Bi-GRU layer to generate part of speech and sentence representation. Then the lexical information is considered via attention over output of softmax activation on part of speech representation. In addition, we combine probability of auxiliary labels as feature with hidden layer to capturing crucial correlation between output labels. The experimental result shows that our model is computationally efficient and achieves breakthrough improvements on customer reviews dataset.

  18. 25 CFR 213.10 - Lessor's signature.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Lessor's signature. 213.10 Section 213.10 Indians BUREAU... MEMBERS OF FIVE CIVILIZED TRIBES, OKLAHOMA, FOR MINING How to Acquire Leases § 213.10 Lessor's signature... thumbprint which shall be designated as “right” or “left” thumbmark. Such signatures must be witnessed by two...

  19. 7 CFR 1951.213 - Debt settlement.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 14 2010-01-01 2009-01-01 true Debt settlement. 1951.213 Section 1951.213 Agriculture... and Grants § 1951.213 Debt settlement. Subpart C of part 1956 of this chapter prescribes policies and procedures for debt settlement actions for loans covered under this subpart when it is determined that a debt...

  20. 45 CFR 213.23a - Discovery.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 2 2010-10-01 2010-10-01 false Discovery. 213.23a Section 213.23a Public Welfare... Discovery. The Department and any party named in the notice issued pursuant to § 213.11 shall have the right to conduct discovery (including depositions) against opposing parties. Rules 26-37 of the Federal...

  1. Development of radioactively labelled cancer seeking biomolecules for targeted radiotherapy. Uruguay

    International Nuclear Information System (INIS)

    Balter, H.; Verdera, S.

    2000-01-01

    The main objective of this project is the labelling and quality control of biomolecules with radionuclides beta emitters with high purity and stability. Techniques and methodology for labelling with 188 Re, 153 Sm, and 125 I as well as quality controls were done according to the recommendations of the first research coordination meeting of this CRP. Also some useful chelators reported in the literature were synthesized in our laboratory)

  2. Compartmental and dosimetric studies of anti-CD20 labelled with {sup 188}Re; Estudo compartimental e dosimetrico do Anti-CD20 marcado com {sup 188}Re

    Energy Technology Data Exchange (ETDEWEB)

    Kuramoto, Graciela Barrio

    2016-10-01

    The radioimmunotherapy (RIT) uses MAbs conjugated to radionuclides α or β{sup -} emitters, both for therapy. Your treatment is based on the irradiation and tumor destruction, preserving the normal organs as the excess radiation. Radionuclides β{sup -} emitters as {sup 131}I, {sup 90}Y, {sup 188}Re {sup 177}Lu and are useful for the development of therapeutic radiopharmaceuticals and, when coupled with MAb and Anti-CD20 it is important mainly for the treatment of non-Hodgkin's lymphomas (NHL). {sup 188}Re (E{sub β} = 2.12 MeV; E{sub γ} = 155 keV; t1/2 = 16.9 h) is an attractive radionuclide for RIT. However, {sup 188}Re can be obtained from a radionuclide generator of {sup 188}W/{sup 188}Re, commercially available, making it convenient for use in research and for clinical routine. The CR of IPEN has a project aimed at the production of radiopharmaceutical {sup 188}Re-Anti-CD20, where the radionuclide can be obtained from a generator system {sup 188}W/{sup 188}Re. With this proposed a study to assess the efficiency of this labeling technique for treatment in accordance compartmental and dosimetry. The objective of this study was to compare the marking of anti-CD20 MAb with {sup 188}Re with the marking of the antibody with {sup 90}Y, {sup 131}I, {sup 177}Lu and {sup 99m}Tc (for their similar chemical characteristics) and {sup 211}At, {sup 213}Bi, {sup 223}Ra and {sup 225}Ac); through the study of labeling techniques reported in literature, the proposal of a compartmental model to evaluate its pharmacokinetic and dosimetric studies, high interest for therapy. The result of the study shows a favorable kinetics for {sup 188}Re, by their physical and chemical characteristics compared to the other evaluated radionuclides. The compartment proposed study describes the metabolism of {sup 188}Reanti- CD20 through a compartment mammillary model, which by their pharmacokinetic analysis, performed compared to products emitters β{sup -131}I-labeled anti CD20, {sup 177

  3. High brightness fiber laser pump sources based on single emitters and multiple single emitters

    Science.gov (United States)

    Scheller, Torsten; Wagner, Lars; Wolf, Jürgen; Bonati, Guido; Dörfel, Falk; Gabler, Thomas

    2008-02-01

    Driven by the potential of the fiber laser market, the development of high brightness pump sources has been pushed during the last years. The main approaches to reach the targets of this market had been the direct coupling of single emitters (SE) on the one hand and the beam shaping of bars and stacks on the other hand, which often causes higher cost per watt. Meanwhile the power of single emitters with 100μm emitter size for direct coupling increased dramatically, which also pushed a new generation of wide stripe emitters or multi emitters (ME) of up to 1000μm emitter size respectively "minibars" with apertures of 3 to 5mm. The advantage of this emitter type compared to traditional bars is it's scalability to power levels of 40W to 60W combined with a small aperture which gives advantages when coupling into a fiber. We show concepts using this multiple single emitters for fiber coupled systems of 25W up to 40W out of a 100μm fiber NA 0.22 with a reasonable optical efficiency. Taking into account a further efficiency optimization and an increase in power of these devices in the near future, the EUR/W ratio pushed by the fiber laser manufacturer will further decrease. Results will be shown as well for higher power pump sources. Additional state of the art tapered fiber bundles for photonic crystal fibers are used to combine 7 (19) pump sources to output powers of 100W (370W) out of a 130μm (250μm) fiber NA 0.6 with nominal 20W per port. Improving those TFB's in the near future and utilizing 40W per pump leg, an output power of even 750W out of 250μm fiber NA 0.6 will be possible. Combined Counter- and Co-Propagated pumping of the fiber will then lead to the first 1kW fiber laser oscillator.

  4. Low emittance electron storage rings

    Science.gov (United States)

    Levichev, E. B.

    2018-01-01

    Low-emittance electron (positron) beams are essential for synchrotron light sources, linear collider damping rings, and circular Crab Waist colliders. In this review, the principles and methods of emittance minimization are discussed, prospects for developing relativistic electron storage rings with small beam phase volume are assessed, and problems related to emittance minimization are examined together with their possible solutions. The special features and engineering implementation aspects of various facilities are briefly reviewed.

  5. Preparation and in vivo evaluation of a novel stabilized linker for 211At labeling of protein

    International Nuclear Information System (INIS)

    Talanov, Vladimir S.; Garmestani, Kayhan; Regino, Celeste A.S.; Milenic, Diane E.; Plascjak, Paul S.; Waldmann, Thomas A.; Brechbiel, Martin W.

    2006-01-01

    Significant improvement of in vivo stability of 211 At-labeled radioimmunoconjugates achieved upon employment of a recently reported new linker, succinimidyl N-2-(4-[ 211 At]astatophenethyl)succinamate (SAPS), prompted additional studies of its chemistry. The 211 At radiolabeling of succinimidyl N-2-(4-tributylstannylphenethyl)succinamate (1) was noted to decline after storage at -15 o C for greater than 6 months. Compound 1 was found to degrade via a ring closure reaction with the formation of N-2-(4-tributylstannylphenethyl)succinimide (3), and a modified procedure for the preparation of 1 was developed. The N-methyl structural analog of 1, succinimidyl N-2-(4-tributylstannylphenethyl)-N-methyl succinamate (SPEMS), was synthesized to investigate the possibility of improving the stability of reagent-protein linkage chemistry. Radiolabeling of SPEMS with 211 At generates succinimidyl N-2-(4-[ 211 At]astatophenethyl)-N-methyl succinamate (Methyl-SAPS), with yields being consistent for greater than 1 year. Radiolabelings of 1 and SPEMS with 125 I generated succinimidyl N-2-(4-[ 125 I]iodophenethyl)succinamate (SIPS) and succinimidyl N-2-(4-[ 125 I]iodophenethyl)-N-methyl succinamate (Methyl-SIPS), respectively, and showed no decline in yields. Methyl-SAPS, SAPS, Methyl-SIPS and SIPS were conjugated to Herceptin for a comparative assessment in LS-174T xenograft-bearing mice. The conjugates of Herceptin with Methyl-SAPS or Methyl-SIPS demonstrated immunoreactivity equivalent to if not superior to the SAPS and SIPS paired analogs. The in vivo studies also revealed that the N-methyl modification resulted in a superior statinated product

  6. 49 CFR 213.3 - Application.

    Science.gov (United States)

    2010-10-01

    ... an urban area that are not connected with the general railroad system of transportation. ... 49 Transportation 4 2010-10-01 2010-10-01 false Application. 213.3 Section 213.3 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF...

  7. Modified theoretical minimum emittance lattice for an electron storage ring with extreme-low emittance

    Directory of Open Access Journals (Sweden)

    Yi Jiao

    2011-05-01

    Full Text Available In the continuing efforts to reduce the beam emittance of an electron storage ring composed of theoretical minimum emittance (TME lattice, down to a level of several tens of picometers, nonlinear dynamics grows to be a great challenge to the performance of the storage ring because of the strong sextupoles needed to compensate for its large global natural chomaticities coupled with its small average dispersion function. To help in dealing with the challenge of nonlinear optimization, we propose a novel variation of theoretical minimum emittance (TME lattice, named as “modified-TME” lattice, with minimal emittance about 3 times of the exact theoretical minimum, while with more compact layout, lower phase advance per cell, smaller natural chromaticities, and more relaxed optical functions than that in a TME cell, by using horizontally defocusing quadrupole closer to the dipole or simply combined-function dipole with horizontally defocusing gradient. We present approximate scaling formulas to describe the relationships of the design parameters in a modified-TME cell. The applications of modified-TME lattice in the PEP-X storage ring design are illustrated and the proposed lattice appears a good candidate for synchrotron radiation light source with extremely low emittance.

  8. A device for electron gun emittance measurement

    International Nuclear Information System (INIS)

    Aune, B.; Corveller, P.; Jablonka, M.; Joly, J.M.

    1985-05-01

    In order to improve the final emittance of the beam delivered by the ALS electron linac a new gun is going to be installed. To measure its emittance and evaluate the contribution of different factors to emittance growth we have developed an emittance measurement device. We describe the experimental and mathematical procedure we have followed, and give some results of measurements

  9. 29 CFR 2.13 - Audiovisual coverage prohibited.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Audiovisual coverage prohibited. 2.13 Section 2.13 Labor Office of the Secretary of Labor GENERAL REGULATIONS Audiovisual Coverage of Administrative Hearings § 2.13 Audiovisual coverage prohibited. The Department shall not permit audiovisual coverage of the...

  10. 42 CFR 93.213 - Institution.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Institution. 93.213 Section 93.213 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES HEALTH ASSESSMENTS AND HEALTH EFFECTS STUDIES OF HAZARDOUS SUBSTANCES RELEASES AND FACILITIES PUBLIC HEALTH SERVICE POLICIES ON RESEARCH...

  11. 49 CFR 213.110 - Gage restraint measurement systems.

    Science.gov (United States)

    2010-10-01

    ... requirements specified in §§ 213.109 and 213.127. (5) If the PTLF becomes non-functional or is missing, the... and fastener requirements specified in §§ 213.109 and 213.127 provided that— (1) The track owner... the minimum design requirements of a GRMS vehicle which specify that— (1) Gage restraint shall be...

  12. 32 CFR 724.213 - Attendance of witnesses.

    Science.gov (United States)

    2010-07-01

    ... BOARD Authority/Policy for Departmental Discharge Review § 724.213 Attendance of witnesses. Arrangement for attendance of witnesses testifying in behalf of the applicant at discharge review hearings is the... 32 National Defense 5 2010-07-01 2010-07-01 false Attendance of witnesses. 724.213 Section 724.213...

  13. In vitro cytotoxicity of alpha conjugates for human pancreatic cancer cell lines

    International Nuclear Information System (INIS)

    Qu, C.; Li, Y.; Rizvi, M.A.; Allen, B.; Samra, J.; Smith, R.

    2003-01-01

    Targeted Alpha therapy (TAT) can inhibit the growth of micrometastases by selectively killing isolated and preangiogenic clusters of cancer cells. The aim of this study is to demonstrate the cytotoxicity of different alpha conjugates in vitro to human metastatic pancreatic cancer cell lines (CAPAN-1, CFPAN-1 and PANC-1). We are labeling the C595 and J591 (non-specific controls) monoclonal antibodies (Mabs) with 213 Bi were performed according to the standard methods in our laboratory. 213 Bi-C595 is specifically cytotoxic to CAPAN-1, CFPAN-1 and PANC-1cell lines in a concentration-dependent fashion. While non-specific alpha conjugates only killed very small fractions of pancreatic cancer cells. These alpha conjugates might be useful agents for the treatment of micro-metastases in pancreatic cancer patients with over-expression of the targeted receptors

  14. 30 CFR 75.213 - Roof support removal.

    Science.gov (United States)

    2010-07-01

    ... mining experience shall perform permanent roof support removal work. (b) Prior to the removal of... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Roof support removal. 75.213 Section 75.213... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Roof Support § 75.213 Roof support removal. (a)(1) All...

  15. Diamond-based single-photon emitters

    International Nuclear Information System (INIS)

    Aharonovich, I; Castelletto, S; Simpson, D A; Su, C-H; Greentree, A D; Prawer, S

    2011-01-01

    The exploitation of emerging quantum technologies requires efficient fabrication of key building blocks. Sources of single photons are extremely important across many applications as they can serve as vectors for quantum information-thereby allowing long-range (perhaps even global-scale) quantum states to be made and manipulated for tasks such as quantum communication or distributed quantum computation. At the single-emitter level, quantum sources also afford new possibilities in terms of nanoscopy and bio-marking. Color centers in diamond are prominent candidates to generate and manipulate quantum states of light, as they are a photostable solid-state source of single photons at room temperature. In this review, we discuss the state of the art of diamond-based single-photon emitters and highlight their fabrication methodologies. We present the experimental techniques used to characterize the quantum emitters and discuss their photophysical properties. We outline a number of applications including quantum key distribution, bio-marking and sub-diffraction imaging, where diamond-based single emitters are playing a crucial role. We conclude with a discussion of the main challenges and perspectives for employing diamond emitters in quantum information processing.

  16. Emittance compensation of CW DC-gun photoinjector

    International Nuclear Information System (INIS)

    Li Peng; Wu Dai; Xu Zhou; Li Ming; Yang Xingfan

    2011-01-01

    Emittance growth induced by space charge effect is very important, especially for CW DC-gun photoinjector. In this work, the linear space charge force and its effect on electron beam transverse emittance are studied, and the principle and properties of emittance compensation by solenoid are analyzed. The CAEP DC-gun photoinjector with a solenoid is also simulated by code Parmela. Simulated results indicate that the normalized transverse emittance of an 80 pC bunch at the 350 keV DC-gun ex-it is 5.14 mm · mrad. And after compensated by a solenoid, it becomes 1.27 mm · mrad. The emittance of beam is well compensated. (authors)

  17. A low-emittance lattice for SPEAR

    International Nuclear Information System (INIS)

    Safranek, J.; Wiedemann, H.

    1992-01-01

    The design and implementation of a low emittance lattice for the SPEAR storage ring including measurements of the performance of the lattice are presented (J. Safranek, Ph. D. thesis, Stanford University, 1991). The low emittance lattice is designed to optimize the performance of SPEAR as a synchrotron radiation source while keeping SPEAR hardware changes at a minimum. The horizontal emittance of the electron beam in the low emittance lattice is reduced by a factor of 4 from the previous lattice. This reduces the typical horizontal source size and divergence of the photon beams by a factor of 2 each and increases the photon beam brightness. At 3 GeV the horizontal emittance is 129 π nm rad, which makes the low emittance lattice the lowest emittance, runnning synchroton radiation source in the world in the 1.5 to 4.0 GeV energy range for the emittance scaled to 3 GeV. The measured vertical emittance was reduced to half that typically seen at SPEAR in the past. The brightness of the photon beams was further incrased by reducing β y at the insertion devices to 1.1 m and reducing the energy dispersion at the insertion devices by more than a factor of 2 on average. The horizontal despersion at the rf cavities was reduced by a factor of nearly 4 which gives much less problems with synchrobetatron resonances. The dynamic and physical apertures of the lattice are large, giving long beam lifetimes and easy injection of electrons. The measurements of the linear optics and intensity dependent phenomena gave resonable agreement with the design . The overall performance of the machine was very good. Injection rates of 10 to 20 mA/min and larger were achieved routinely, and 100 mA total current was stored. Repeated ramping of stored beam from the injection energy of 2.3 GeV to the running energy of 3.0 GeV was achieved with very little beam loss. This low emittance configuration is expected to be the operating configuration for SPEAR starting in January 1992. (orig.)

  18. Radiation emitter-detector package

    International Nuclear Information System (INIS)

    O'Brien, J.T.; Limm, A.C.; Nyul, P.; Tassia, V.S. Jr.

    1978-01-01

    Mounted on the metallic base of a radiation emitter-detector is a mounting block is a first projection, and a second projection. A radiation detector is on the first projection and a semiconductor electroluminescent device, i.e., a radiation emitter, is on the second projection such that the plane of the recombination region of the electroluminescent device is perpendicular to the radiation incident surface of the radiation detector. The electroluminescent device has a primary emission and a secondary emission in a direction different from the primary emission. A radiation emitter-detector package as described is ideally suited to those applications wherein the secondary radiation of the electroluminescent device is fed into a feedback circuit regulating the biasing current of the electroluminescent device

  19. Emittance investigation of RF photo-injector

    CERN Document Server

    Yang Mao Rong; Li Zheng; Li Ming; Xu Zhou

    2002-01-01

    A high-power laser beam illuminates a photocathode surface placed on an end wall of an RF cavity. The emitted electrons are accelerated immediately to a relativistic energy by the strong RF find in the cavity. But space charge effect induces beam emittance growth especially near the cathode where the electrons are still nonrelativistic. The author analyzes the factors which lead the transverse emittance growth and method how to resolve this problem. After introducing solenoidal focusing near the photocathode, the beam emittance growth is suppressed dramatically. The beam emittance is given also after compensation and simulation results. The measurements show these results are coincident

  20. Dicty_cDB: CFE213 [Dicty_cDB

    Lifescience Database Archive (English)

    Full Text Available CF (Link to library) CFE213 (Link to dictyBase) - - - Contig-U16381-1 CFE213F (Link... to Original site) CFE213F 111 - - - - - - Show CFE213 Library CF (Link to library) Clone ID CFE213 (Link to dict...yBase) Atlas ID - NBRP ID - dictyBase ID - Link to Contig Contig-U16381-1 Original site URL http://dict... E Sequences producing significant alignments: (bits) Value N AC115685 |AC115685.1 Dict...yostelium discoideum chromosome 2 map 4718821-4752388 strain AX4, complete sequence. 80 9e-24 3 X51892 |X51892.1 Dict

  1. Criteria for emittance compensation in high-brightness photoinjectors

    Directory of Open Access Journals (Sweden)

    Chun-xi Wang

    2007-10-01

    Full Text Available A critical process in high-brightness photoinjectors is emittance compensation, which brings under control the correlated transverse emittance growth due to the linear space-charge force. Although emittance compensation has been used and studied for almost two decades, the exact criteria to achieve emittance compensation is not as clear as it should be. In this paper, a perturbative analysis of slice envelopes and emittance evolution close to any reference envelope is developed, via which space-charge and chromatic effects are investigated. A new criterion for emittance compensation is found, which is complementary to the well-known matching condition for the invariant envelope and agrees very well with simulations.

  2. SOI Fully complementary BI-JFET-MOS technology for analog-digital applications with vertical BJT's

    International Nuclear Information System (INIS)

    Delevoye, E.; Blanc, J.P.; Bonaime, J.; Pontcharra, J. de; Gautier, J.; Martin, F.; Truche, R.

    1993-01-01

    A silicon-on-insulator, fully complementary, Bi-JFET-MOS technology has been developed for realizing multi-megarad hardened mixed analog-digital circuits. The six different active components plus resistors and capacitors have been successfully integrated in a 25-mask process using SIMOX substrate and 1 μm thick epitaxial layer. Different constraints such as device compatibility, complexity not higher than BiCMOS technology and breakdown voltages suitable for analog applications have been considered. Several process splits have been realized and all the characteristics presented here have been measured on the same split. P + gate is used for PMOS transistor to get N and PMOST symmetrical characteristics. Both NPN and PNP vertical bipolar transistors with poly-emitters show f T > 5 GHz. 2-separated gate JFET's need no additional mask. (authors). 9 figs., 1 tab

  3. Small horizontal emittance in the TESLA damping ring

    International Nuclear Information System (INIS)

    Decking, W.

    2001-01-01

    The present TESLA damping ring is designed for a normalized horizontal emittance of 8x10 -6 m. γ-γ collisions at the TESLA linear collider will benefit from a further decrease of the horizontal emittance. This paper reviews the processes which limit the horizontal emittance in the damping ring. Preliminary estimates on the smallest horizontal emittance for the present TESLA damping ring design as well as an ultimate limit of the emittance reachable with the TESLA damping ring concept will be given

  4. 21 CFR 21.3 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Definitions. 21.3 Section 21.3 Food and Drugs FOOD... products regulated by the Food and Drug Administration or with which the Food and Drug Administration has business dealings. Any such business enterprise that is identified by the name of one or more individuals...

  5. Beam diagnostics using an emittance measurement device

    International Nuclear Information System (INIS)

    Sarstedt, M.; Becker, R.; Klein, H.; Maaser, A.; Mueller, J.; Thomae, R.; Weber, M.

    1995-01-01

    For beam diagnostics aside from Faraday cups for current measurements and analysing magnets for the determination of beam composition and energy the most important tool is an emittance measurement device. With such a system the distribution of the beam particles in phase-space can be determined. This yields information not only on the position of the particles but also on their angle with respect to the beam axis. There are different kinds of emittance measurement devices using either circular holes or slits for separation of part of the beam. The second method (slit-slit measurement), though important for the determination of the rms-emittance, has the disadvantage of integrating over the y- and y'-coordinate (measurement in xx'-plane assumed). This leads to different emittance diagrams than point-point measurements, since in xx'-plane for each two corresponding points of rr'-plane there exists a connecting line. With regard to beam aberrations this makes xx'-emittances harder to interpret. In this paper the two kinds of emittance diagrams are discussed. Additionally the influence of the slit height on the xx'-emittance is considered. The analytical results are compared to experimental measurements in rr'-, rx'- and xx'-phase-space. (orig.)

  6. Nonintercepting emittance monitor

    International Nuclear Information System (INIS)

    Miller, R.H.; Clendenin, J.E.; James, M.B.; Sheppard, J.C.

    1983-08-01

    A nonintercepting emittance monitor is a helpful device for measuring and improving particle beams in accelerators and storage rings as it allows continuous monitoring of the beam's distribution in phase space, and perhaps closed loop computer control of the distributions. Stripline position monitors are being investigated for use as nonintercepting emittance monitors for a beam focused by a FODO array in the first 100 meters of our linear accelerator. The technique described here uses the signal from the four stripline probes of a single position monitor to measure the quadrupole mode of the wall current in the beam pipe. This current is a function of the quadrupole moment of the beam, sigma 2 /sub x/ - sigma 2 /sub y/. In general, six independent measurements of the quadrupole moment are necessary to determine the beam emittance. This technique is dependent on the characteristically large variations of sigma 2 /sub x/ - sigma 2 /sub y/ in a FODO array. It will not work in a focusing system where the beam is round at each focusing element

  7. Low emittance configuration for spear

    International Nuclear Information System (INIS)

    Blumberg, L.N.; Harris, J.; Stege, R.; Cerino, J.; Hettel, R.; Hofmann, A.; Liu, R.Z.; Wiedemann, H.; Winick, H.

    1985-01-01

    The quality of synchrotron radiation beams from SPEAR, in particular the brilliance of undulator radiation, can be improved significantly by reducing the emittance of the stored electron beam. A reduction of the horizontal emittance by a factor of 3.5 to a value of 130 nanometer-radians (nm-r) at 3 GeV has been achieved by using stronger focussing, mainly in the horizontal plane. The low emittance configuration also reduces the dispersion and vertical beta functions in the straight sections, making them more suitable for wigglers. The higher betatron tunes lead to a larger phase advance between the two kickers, which has to be corrected during injection by shunting current from some quadrupoles. The configuration was optimized within SPEAR hardware limitations and tested for dynamic aperture with the tracking program PATRICIA. After implementation of this scheme, beam was successfully injected and accumulated. The measured emittance of the stored beam was in agreement with calculations. Presently the configuration is being made operational

  8. Emittance measurements by variable quadrupole method

    International Nuclear Information System (INIS)

    Toprek, D.

    2005-01-01

    The beam emittance is a measure of both the beam size and beam divergence, we cannot directly measure its value. If the beam size is measured at different locations or under different focusing conditions such that different parts of the phase space ellipse will be probed by the beam size monitor, the beam emittance can be determined. An emittance measurement can be performed by different methods. Here we will consider the varying quadrupole setting method.

  9. The labeling of white blood cells with 99mTc and 111In complexes

    International Nuclear Information System (INIS)

    Hadizad, T.; Najafi, R.

    1993-01-01

    Leukocytes have been labelled with a variety of gamma emitters and labelled (mixed) leukocytes are used clinically to detect and localize sites of abscess in the abdominal area and inflammatory processes surrounding grafts, ulcerative colitis and study of leukocyte kinetics. In this project we used 99m Tc-Sn-Pyp, 99m Tc-Hexamethyl propenylamine oxine, 111 In-Tropolone and 111 In-Oxine Sulfate for the labelling of leukocytes. All the in vitro and in vivo tests have been done to get an optimum condition for injection

  10. Multinozzle emitter arrays for ultrahigh-throughput nanoelectrospray mass spectrometry

    Science.gov (United States)

    Wang, Daojing; Mao, Pan; Wang, Hung-Ta; Yang, Peidong

    2017-10-17

    The present invention provides for a structure comprising a plurality of emitters, wherein a first nozzle of a first emitter and a second nozzle of a second emitter emit in two directions that are not or essentially not in the same direction; wherein the walls of the nozzles and the emitters form a monolithic whole. The present invention also provides for a structure comprising an emitter with a sharpened end from which the emitter emits; wherein the emitters forms a monolithic whole. The present invention also provides for a fully integrated separation of proteins and small molecules on a silicon chip before the electrospray mass spectrometry analysis.

  11. Hybrid emitter all back contact solar cell

    Science.gov (United States)

    Loscutoff, Paul; Rim, Seung

    2016-04-12

    An all back contact solar cell has a hybrid emitter design. The solar cell has a thin dielectric layer formed on a backside surface of a single crystalline silicon substrate. One emitter of the solar cell is made of doped polycrystalline silicon that is formed on the thin dielectric layer. The other emitter of the solar cell is formed in the single crystalline silicon substrate and is made of doped single crystalline silicon. The solar cell includes contact holes that allow metal contacts to connect to corresponding emitters.

  12. Emittance measurements of the CLIO electron beam

    Science.gov (United States)

    Chaput, R.; Devanz, G.; Joly, P.; Kergosien, B.; Lesrel, J.

    1997-02-01

    We have designed a setup to measure the transverse emittance at the CLIO accelerator exit, based on the "3 gradients" method. The beam transverse size is measured simply by scanning it with a steering coil across a fixed jaw and recording the transmitted current, at various quadrupole strengths. A code then performs a complete calculation of the emittance using the transfer matrix of the quadrupole instead of the usual classical lens approximation. We have studied the influence of various parameters on the emittance: Magnetic field on the e-gun and the peak current. We have also improved a little the emittance by replacing a mismatched pipe between the buncher and accelerating section to avoid wake-field effects; The resulting improvements of the emittance have led to an increase in the FEL emitted power.

  13. 19 CFR 213.5 - Access to Commission resources.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 3 2010-04-01 2010-04-01 false Access to Commission resources. 213.5 Section 213.5 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION INVESTIGATIONS OF UNFAIR PRACTICES IN IMPORT TRADE TRADE REMEDY ASSISTANCE § 213.5 Access to Commission resources. Commission resources, in...

  14. 2-D emittance equation with acceleration and compression

    International Nuclear Information System (INIS)

    Hahn, K.D.; Smith, L.

    1988-10-01

    Since both acceleration and compression are required for an Inertial Fusion Driver, the understanding of their effect on the beam quality, emittance, is important. This report attempts to generalize the usual emittance formula for the drifting beam to include these effects. The derivation of the 2-D emittance equation is carried out and a comparison with the particle code results is given. The 2-D emittance at a given axial location is reasonable to consider for a long beam, particularly with velocity tilt; transverse emittance averaged over the entire bunch is not a useful quantity. 6 refs., 2 figs., 1 tab

  15. Emittance growth in rf linacs

    International Nuclear Information System (INIS)

    Jameson, R.A.

    1979-01-01

    As the space-charge limit is approached, the current that can be accelerated in an rf linac and the output emittance that can be expected are discussed. The role of the envelope equations to estimate limits is outlined. The results of numerical experiments to explore general properties of emittance growth are given

  16. Self-decomposition components generated from [sup 35]S-labeled amino acids

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Takahisa; Saito, Kazumi; Kurihara, Norio (Kyoto Univ. (Japan). Radioisotope Research Center)

    1994-06-01

    We examined the fragment molecules in the gaseous components generated from [sup 35]S-amino acids with high specific radioactivity. The self-decomposition mode of a molecule labeled with a [beta]-emitter was similar to the fragmentation mode of organic compounds impacted by accelerated electrons as in organic mass spectrometry. Degradation products of unlabeled amino acids irradiated by [sup 60]Co [gamma]-ray indicated that the degradation mode induced by external [gamma]-rays irradiation was different from the self-decomposition mode of labeled compounds. (Author).

  17. Minimum emittance in TBA and MBA lattices

    Science.gov (United States)

    Xu, Gang; Peng, Yue-Mei

    2015-03-01

    For reaching a small emittance in a modern light source, triple bend achromats (TBA), theoretical minimum emittance (TME) and even multiple bend achromats (MBA) have been considered. This paper derived the necessary condition for achieving minimum emittance in TBA and MBA theoretically, where the bending angle of inner dipoles has a factor of 31/3 bigger than that of the outer dipoles. Here, we also calculated the conditions attaining the minimum emittance of TBA related to phase advance in some special cases with a pure mathematics method. These results may give some directions on lattice design.

  18. Minimum emittance in TBA and MBA lattices

    International Nuclear Information System (INIS)

    Xu Gang; Peng Yuemei

    2015-01-01

    For reaching a small emittance in a modern light source, triple bend achromats (TBA), theoretical minimum emittance (TME) and even multiple bend achromats (MBA) have been considered. This paper derived the necessary condition for achieving minimum emittance in TBA and MBA theoretically, where the bending angle of inner dipoles has a factor of 3 1/3 bigger than that of the outer dipoles. Here, we also calculated the conditions attaining the minimum emittance of TBA related to phase advance in some special cases with a pure mathematics method. These results may give some directions on lattice design. (authors)

  19. Nuclear Data Sheets for A=213

    International Nuclear Information System (INIS)

    Basunia, M.S.

    2007-01-01

    Evaluated spectroscopic data and level schemes from radioactive decay and nuclear reaction studies are presented for all nuclei with mass number A=213. This evaluation for A=213 supersedes the earlier one by Y. A. Akovali (1992Ak01), published in Nuclear Data Sheets 66, 237 (1992)

  20. Cancer from internal emitters

    International Nuclear Information System (INIS)

    Boecker, B.B.; Griffith, W.C. Jr.

    1995-01-01

    Irradiation from internal emitters, or internally deposited radionuclides, is an important component of radiation exposures encountered in the workplace, home, or general environment. Long-term studies of human populations exposed to various internal emitters by different routes of exposure are producing critical information for the protection of workers and members of the general public. The purpose of this report is to examine recent developments and discuss their potential importance for understanding lifetime cancer risks from internal emitters. The major populations of persons being studied for lifetime health effects from internally deposited radionuclides are well known: Lung cancer in underground miners who inhaled Rn progeny, liver cancer from persons injected with the Th-containing radiographic contrast medium Thorotrast, bone cancer from occupational or medical intakes of 226 Ra or medical injections of 224 Ra, and thyroid cancer from exposures to iodine radionuclides in the environment or for medical purposes

  1. Development of Emittance Analysis Software for Ion Beam Characterization

    International Nuclear Information System (INIS)

    Padilla, M.J.; Liu, Yuan

    2007-01-01

    Transverse beam emittance is a crucial property of charged particle beams that describes their angular and spatial spread. It is a figure of merit frequently used to determine the quality of ion beams, the compatibility of an ion beam with a given beam transport system, and the ability to suppress neighboring isotopes at on-line mass separator facilities. Generally, a high-quality beam is characterized by a small emittance. In order to determine and improve the quality of ion beams used at the Holifield Radioactive Ion Beam Facility (HRIBF) for nuclear physics and nuclear astrophysics research, the emittances of the ion beams are measured at the off-line Ion Source Test Facilities. In this project, emittance analysis software was developed to perform various data processing tasks for noise reduction, to evaluate root-mean-square emittance, Twiss parameters, and area emittance of different beam fractions. The software also provides 2D and 3D graphical views of the emittance data, beam profiles, emittance contours, and RMS. Noise exclusion is essential for accurate determination of beam emittance values. A Self-Consistent, Unbiased Elliptical Exclusion (SCUBEEx) method is employed. Numerical data analysis techniques such as interpolation and nonlinear fitting are also incorporated into the software. The software will provide a simplified, fast tool for comprehensive emittance analysis. The main functions of the software package have been completed. In preliminary tests with experimental emittance data, the analysis results using the software were shown to be accurate

  2. DEVELOPMENT OF EMITTANCE ANALYSIS SOFTWARE FOR ION BEAM CHARACTERIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Padilla, M. J.; Liu, Y.

    2007-01-01

    Transverse beam emittance is a crucial property of charged particle beams that describes their angular and spatial spread. It is a fi gure of merit frequently used to determine the quality of ion beams, the compatibility of an ion beam with a given beam transport system, and the ability to suppress neighboring isotopes at on-line mass separator facilities. Generally a high quality beam is characterized by a small emittance. In order to determine and improve the quality of ion beams used at the Holifi eld Radioactive Ion beam Facility (HRIBF) for nuclear physics and nuclear astrophysics research, the emittances of the ion beams are measured at the off-line Ion Source Test Facilities. In this project, emittance analysis software was developed to perform various data processing tasks for noise reduction, to evaluate root-mean-square emittance, Twiss parameters, and area emittance of different beam fractions. The software also provides 2D and 3D graphical views of the emittance data, beam profi les, emittance contours, and RMS. Noise exclusion is essential for accurate determination of beam emittance values. A Self-Consistent, Unbiased Elliptical Exclusion (SCUBEEx) method is employed. Numerical data analysis techniques such as interpolation and nonlinear fi tting are also incorporated into the software. The software will provide a simplifi ed, fast tool for comprehensive emittance analysis. The main functions of the software package have been completed. In preliminary tests with experimental emittance data, the analysis results using the software were shown to be accurate.

  3. Role of metabolic activation by cytochrome P-450 in covalent binding of VP 16-213 to rat liver and HeLa cell microsomal proteins

    Energy Technology Data Exchange (ETDEWEB)

    van Maanen, J.M.; de Ruiter, C.; de Vries, J.; Kootstra, P.R.; Gobas, F.; Pinedo, H.M.

    1985-09-01

    Covalent binding of /sup 3/H-labeled VP 16-213 to rat liver and HeLa cell microsomal proteins was studied in vitro. Metabolic activation by cytochrome P-450 was found to play a role in the covalent binding of VP 16-213 to rat liver microsomal proteins, as shown by the need of NADPH cofactor, the increased binding after phenobarbital pretreatment and the inhibition by SFK-525A. Addition of ascorbic acid or alpha-phenyl-N-tert. butylnitrone to the incubation mixture depressed covalent binding by about 85%, suggesting that formation of a reactive metabolite from the phenolic structure may be involved in the binding process. VP 16-213 did not inhibit aminopyrine N-demethylase at the concentration used in the binding experiments (17 microM), indicating that metabolism of its methylenedioxy group does not play a role in binding to microsomal proteins. HeLa cell microsomes were found to possess aminopyrine N-demethylase activity. Covalent binding of radiolabeled VP 16-213 to HeLa cell microsomes decreased by about 64% if NADPH was omitted.

  4. 25 CFR 213.43 - Relinquishment of Government supervision.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Relinquishment of Government supervision. 213.43 Section 213.43 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR ENERGY AND MINERALS LEASING OF RESTRICTED LANDS OF MEMBERS OF FIVE CIVILIZED TRIBES, OKLAHOMA, FOR MINING Removal of Restrictions § 213.43 Relinquishment of Government supervision....

  5. Indium-111 labeling of leukocytes: a detrimental effect on neutrophil and lymphocyte function and an improved method of cell labelling

    International Nuclear Information System (INIS)

    Segal, A.W.; Deteix, P.; Garcia, R.; Tooth, P.; Zanelli, G.D.; Allison, A.C.

    1978-01-01

    A technique for the labeling of cells with the gamma emitter indium-111 has recently been developed. In this study the effects of the labeling procedure on some in vitro functions of human neutrophils and lymphocytes were investigated. With the standard labeling procedure, neutrophil chemotaxis was reduced to approximately 50% of normal and lymphocytes lost surface receptors and failed to respond to stimulation with phytohemagglutinin. The 8-hydroxyquinoline that is used to chelate the indium is toxic to lymphocytes; accordingly the relationship between the quantity of oxine, the chelation of indium, and cell labeling were investigated. Optimal conditions for In-111 cell labeling were established: 100 million cells in 10 ml Hanks' balanced salt solution are mixed with 5 μg of oxine in a mixture of 50 μl of ethanol and 200 μl of saline; they are incubated at 37 0 C for 10 min and then washed. Initially, neutrophils and lymphocytes appear functionally normal, but after 24 to 48 hr lymphocyte function is impaired as a result of radiation damage. This toxicity may limit studies by external scanning on the distribution and kinetics of lymphocytes labeled with In-111

  6. 5 CFR 213.3199 - Temporary organizations.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Temporary organizations. 213.3199 Section... SERVICE Excepted Schedules Schedule A § 213.3199 Temporary organizations. Positions on the staffs of temporary organizations, as defined in 5 U.S.C. 3161(a). Appointments may not exceed 3 years, but temporary...

  7. Quantum efficiency and thermal emittance of metal photocathodes

    Directory of Open Access Journals (Sweden)

    David H. Dowell

    2009-07-01

    Full Text Available Modern electron beams have demonstrated the brilliance needed to drive free electron lasers at x-ray wavelengths with major advances occurring since the invention of the photocathode gun and the realization of emittance compensation. These state-of-the-art electron beams are now becoming limited by the intrinsic thermal emittance of the cathode. In both dc and rf photocathode guns details of the cathode emission physics strongly influence the quantum efficiency and the thermal emittance. Therefore improving cathode performance is essential to increasing the brightness of beams. It is especially important to understand the fundamentals of cathode quantum efficiency and thermal emittance. This paper investigates the relationship between the quantum efficiency and the thermal emittance for metal cathodes using the Fermi-Dirac model for the electron distribution. We use a consistent theory to derive the quantum efficiency and thermal emittance, and compare our results to those of others.

  8. Vanadium Dioxide as a Natural Disordered Metamaterial: Perfect Thermal Emission and Large Broadband Negative Differential Thermal Emittance

    Directory of Open Access Journals (Sweden)

    Mikhail A. Kats

    2013-10-01

    Full Text Available We experimentally demonstrate that a thin (approximately 150-nm film of vanadium dioxide (VO_{2} deposited on sapphire has an anomalous thermal emittance profile when heated, which arises because of the optical interaction between the film and the substrate when the VO_{2} is at an intermediate state of its insulator-metal transition (IMT. Within the IMT region, the VO_{2} film comprises nanoscale islands of the metal and dielectric phases and can thus be viewed as a natural, disordered metamaterial. This structure displays “perfect” blackbodylike thermal emissivity over a narrow wavelength range (approximately 40  cm^{-1}, surpassing the emissivity of our black-soot reference. We observe large broadband negative differential thermal emittance over a >10 °C range: Upon heating, the VO_{2}-sapphire structure emits less thermal radiation and appears colder on an infrared camera. Our experimental approach allows for a direct measurement and extraction of wavelength- and temperature-dependent thermal emittance. We anticipate that emissivity engineering with thin-film geometries comprising VO_{2} and other thermochromic materials will find applications in infrared camouflage, thermal regulation, and infrared tagging and labeling.

  9. Beam phase space and emittance

    International Nuclear Information System (INIS)

    Buon, J.

    1990-12-01

    The classical and elementary results for canonical phase space, the Liouville theorem and the beam emittance are reviewed. Then, the importance of phase portraits to obtain a geometrical description of motion is emphasized, with examples in accelerator physics. Finally, a statistical point of view is used to define beam emittance, to study its law of approximate conservation and to treat two particular examples

  10. Structure and physical properties of the LaBiFe2O6 Perovskite produced by the modified Pechini method

    International Nuclear Information System (INIS)

    Palacio, Johny Andrés Jaramillo; Bello, Elixir William Barrera; Landínez-Téllez, David A.; Roa-Rojas, Jairo; Cagigas, Julián Andrés Munévar; Arnache, Oscar

    2017-01-01

    In this paper the synthesis of the LaBiFe 2 O 6 material by the modified Pechini method is reported. Structural, morphologic, magnetic and optic experimental studies were performed. Rietveld refinement of x-ray diffraction patterns revealed that LaBiFe 2 O 6 crystallizes in an orthorhombic perovskite structure (space group Pnma, ⧣ 62). Scanning electron microscopy images showed the nanometric feature of grains. X-ray dispersive spectroscopy permitted to infer the obtaining of the LaBiFe 2 O 6 expected stoichiometry. Results of magnetic susceptibility as a function of temperature and field magnetization evidenced mixed ferromagnetism and superparamagnetism behavior at T=300 K. Mössbauer spectroscopy supported the superparamagnetic and ferromagnetic responses as a result of the nanogranular morphology and anisotropy effects. Spectrum of diffuse reflectance suggest that this material behaves as a semiconductor with energy gap E g =2.13 eV. (author)

  11. Generalized superradiant assembly for nanophotonic thermal emitters

    Science.gov (United States)

    Mallawaarachchi, Sudaraka; Gunapala, Sarath D.; Stockman, Mark I.; Premaratne, Malin

    2018-03-01

    Superradiance explains the collective enhancement of emission, observed when nanophotonic emitters are arranged within subwavelength proximity and perfect symmetry. Thermal superradiant emitter assemblies with variable photon far-field coupling rates are known to be capable of outperforming their conventional, nonsuperradiant counterparts. However, due to the inability to account for assemblies comprising emitters with various materials and dimensional configurations, existing thermal superradiant models are inadequate and incongruent. In this paper, a generalized thermal superradiant assembly for nanophotonic emitters is developed from first principles. Spectral analysis shows that not only does the proposed model outperform existing models in power delivery, but also portrays unforeseen and startling characteristics during emission. These electromagnetically induced transparency like (EIT-like) and superscattering-like characteristics are reported here for a superradiant assembly, and the effects escalate as the emitters become increasingly disparate. The fact that the EIT-like characteristics are in close agreement with a recent experimental observation involving the superradiant decay of qubits strongly bolsters the validity of the proposed model.

  12. Internal emitter research and standard setting

    International Nuclear Information System (INIS)

    Stannard, J.N.

    1981-01-01

    The history of the use of data from internal emitter research in the derivation of safety standards is reviewed. At first, observed biological effects were correlated with body burdens or exposure levels. This direct approach is illustrated by detailed accounts of the cases of uranium and plutonium. In the 1950's, when it was decided to provide standards for over 200 isotopes, the direct approach was replaced by a system of calculations. This necessitated changes in internal emitter research programs to provide metabolic data, and the development of models such as Reference Man and the Lung and Gastrointestinal Tract models. The continuing contribution of internal emitter research to standard setting can be seen in the references quoted in the metabolic data section of the new ICRP report (ICRP Publication 30). Present trends suggest a possible return to the direct use of internal emitter effects data for obtaining risk estimates. (U.K.)

  13. Combination of anti-retroviral drugs and radioimmunotherapy specifically kills infected cells from HIV infected individuals

    Directory of Open Access Journals (Sweden)

    Dina Tsukrov

    2016-09-01

    Full Text Available Eliminating virally infected cells is an essential component of any HIV eradication strategy. Radioimmunotherapy (RIT, a clinically established method for killing cells using radiolabeled antibodies, was recently applied to target HIV-1 gp41 antigen expressed on the surface of infect-ed cells. Since gp41 expression by infected cells is likely down-regulated in patients on an-tiretroviral therapy (ART, we evaluated the ability of RIT to kill ART-treated infected cells us-ing both in vitro models and lymphocytes isolated from HIV-infected subjects. Human peripheral blood mononuclear cells (PBMCs were infected with HIV and cultured in the presence of two clinically relevant ART combinations. Scatchard analysis of the 2556 human monoclonal anti-body to HIV gp41 binding to the infected and ART-treated cells demonstrated sufficient residual expression of gp41 on the cell surface to warrant subsequent RIT. This is the first time the quantification of gp41 post-ART is being reported. Cells were then treated with Bismuth-213-labeled 2556 antibody. conjugated to the human monoclonal antibody 2556, which binds to HIV gp41. Cell survival was quantified by Trypan blue and residual viremia by p24 ELISA. Cell surface gp41 expression was assessed by Scatchard analysis. The experiments were repeated using PBMCs isolated from blood specimens obtained from 15 HIV-infected individuals: ten on ART and five ART-naive. We found that 213Bi-2556 killed ART-treated infected PBMCs and reduced viral production to undetectable levels. ART and RIT co-treatment was more effective at reducing viral load in vitro than either therapy alone, indicating that gp41 expression under ART was sufficient to allow 213Bi-2556 to deliver cytocidal doses of radiation to infected cells. This study provides proof of concept that 213Bi-2556 may represent an innovative and effective targeting method for killing HIV-infected cells treated with ART, and supports continued development of 213Bi

  14. 19 CFR 213.6 - Information concerning assistance.

    Science.gov (United States)

    2010-04-01

    ... 213.6 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION INVESTIGATIONS OF UNFAIR PRACTICES IN IMPORT TRADE TRADE REMEDY ASSISTANCE § 213.6 Information concerning assistance. Any person may.... International Trade Commission, 500 E Street SW., Washington, DC 20436. ...

  15. Solid-state single-photon emitters

    Science.gov (United States)

    Aharonovich, Igor; Englund, Dirk; Toth, Milos

    2016-10-01

    Single-photon emitters play an important role in many leading quantum technologies. There is still no 'ideal' on-demand single-photon emitter, but a plethora of promising material systems have been developed, and several have transitioned from proof-of-concept to engineering efforts with steadily improving performance. Here, we review recent progress in the race towards true single-photon emitters required for a range of quantum information processing applications. We focus on solid-state systems including quantum dots, defects in solids, two-dimensional hosts and carbon nanotubes, as these are well positioned to benefit from recent breakthroughs in nanofabrication and materials growth techniques. We consider the main challenges and key advantages of each platform, with a focus on scalable on-chip integration and fabrication of identical sources on photonic circuits.

  16. A low emittance configuration for spear

    International Nuclear Information System (INIS)

    Blumberg, L.N.; Cerino, J.; Harris, J.; Hettel, R.; Hofmann, A.; Liu, R.Z.; Stego, R.; Wiedemann, H.; Winick, H.

    1985-01-01

    The quality of synchrotron radiation beams from SPEAR, in particular the brilliance of undulator radiation, can be improved significantly by reducing the emittance of the stored electron beam. A reduction of the horizontal emittance by a factor of 3.5 to a value of 130 nanometer-radians (nm-r) at 3 GeV has been achieved by using stronger focussing, mainly in the horizontal plane. The low emittance configuration also reduces the dispersion and vertical beta functions in the straight sections, making them more suitable for wigglers. The higher betatron tunes lead to a larger phase advance between the two kickers, which has to be corrected during injection by shunting current from some quadrupoles. The configuration was optimized within SPEAR hardware limitations and tested for dynamic aperture with the tracking program PATRICIA. After implementation of this scheme, beam was successfully injected and accumulated. The measured emittance of the stored beam was in agreement with calculations. Presently the configuration is being made operational

  17. Emittance growth rates for displaced beams

    International Nuclear Information System (INIS)

    Anderson, O.A.

    1993-05-01

    Emittance growth rates have been previously analyzed for nonuniform beams in linear channels and for initially uniform mismatched beams in nonlinear channels. These studies were for centered beams. Additional emittance growth can arise in cases where the beam is initially displaced. The purpose of this study is to obtain growth rates for displaced beams. This work differs from studies involving random displacement of electrodes. Our analysis assumes instead that the focusing system is perfectly aligned but that the beam is initially displaced with respect to the equilibrium axis. If the focusing force is slightly nonlinear, we find a gradual transfer of the potential energy of beam displacement into kinetic energy associated with emittance growth. We present explicit results for the emittance growth distance as a function of the nonlinearity of the channel. These results will have practical importance for designers of accelerators and transport systems when setting realistic tolerances for initial beam alignment. These tolerances will depend on the nonlinearity and the length of the system

  18. Emittance variations in current-amplifying ion induction linacs

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1991-01-01

    Since 1985 the Heavy Ion Fusion Accelerator Research program at the Lawrence Berkeley Laboratory has been studying current amplification and emittance variations in MBE-4, a four-cesium-beam induction linac. This experiment models much of the accelerator physics of the electrostatically focused section of a fusion driver. Four space-charge dominated Cs + beams, initially about one meter in length at currents of 5-10 mA, are focused by electrostatic quadrupoles and accelerated in parallel from approximately 200 keV up to one MeV by 24 accelerating gaps. Final currents of 20-40 mA per beam are typical. Recent experiments with extremely low emittance beams (var-epsilon n =0.03 mm-mRad) have investigated variations of transverse and longitudinal normalized emittance for drifting and accelerating beams. These very strongly tune-depressed beams (σ 0 =72 degree, σ∼6 degree) are difficult to match to the accelerator so as to avoid emittance growth during acceleration. During transport strong emittance fluctuations are observed in good qualitative agreement with simulations. Warmer beams with less tune depression exhibit little to no emittance growth, show smaller emittance fluctuations, and are much easier to match. A summary of findings from the MBE-4 studies is presented

  19. Emittance variations in current-amplifying ion induction linacs

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1991-04-01

    Since 1985 the Heavy Ion Fusion Accelerator Research program at the Lawrence Berkeley Laboratory has been studying current amplification and emittance variations in MBE-4, a four-cesium-beam induction linac. This experiment models much of the accelerator physics of the electrostatically focused section of a fusion driver. Four space-charge dominated Cs + beams, initially about one meter in length at currents of 5--10 mA, are focused by electrostatic quadrupoles and accelerated in parallel from approximately 200 keV up to one MeV by 24 accelerating gaps. Final currents of 20--40 mA per beam are typical. Recent experiments with extremely low emittance beams (ε n = 0.03 mm-mRad) have investigated variations of transverse and longitudinal normalized emittance for drifting and accelerating beams. These very strongly tune-depressed beams (σ o = 72 degrees, σ∼6 degree) are difficult to match the accelerator so as to avoid emittance growth during acceleration. During transport strong emittance fluctuations are observed in good qualitative agreement with simulations. Warmer beams with less tune depression exhibit little to no emittance growth, show smaller emittance fluctuations, and are much easier to match. A summary of findings from the MBE-4 studies is presented. 12 refs., 8 figs

  20. The state of the art in therapeutic nuclear medicine

    International Nuclear Information System (INIS)

    Allen, B.J.

    2001-01-01

    Radionuclide therapy can be curative or palliative in intent, and local or systemic in administration. Current therapy relies of beta emitting radioisotopes and selective carriers for the treatment of advanced tumours. The next generation of therapeutics may be alpha emitting radionuclides for subclinical, micrometastatic disease. Targeted Alpha therapy (TAT) offers the potential to inhibit the growth of micrometastases by selectively killing isolated and preangiogenic clusters of cancer cells. The practicality and efficacy of TAT has been tested by in vitro and in vivo studies many cancers. The first phase 1 clinical trial of TAT for leukaemia with Bi-213 has concluded at the Memorial Sloan Kettering Cancer Center, a phase 1 and 2 trial of intra-lesional TAT is ongoing at Duke University with At-211 labeled Mab against cystic glioma, and a phase 1 and 2 clinical trial for intra-lesional TAT with Bi-213 of subcutaneous secondary melanoma is underway at St George Hospital

  1. Gamma flux responsive self-powered detector with a tubular emitter

    International Nuclear Information System (INIS)

    Goldstein, N.P.; Todt, W.H.

    1982-01-01

    A gamma-sensitive flux detector comprises tubular emitter, an insulating core within the emitter and an insulating layer about the emitter, and a tubular conductive collector electrode about the insulating layer. The emitter material may be platinum, lead, bismuth, tantalum, tungsten; platinum preferred

  2. Emittance Growth in the NLCTA First Chicane

    International Nuclear Information System (INIS)

    Sun, Yipeng

    2011-01-01

    In this paper, the emittance growth in the NLCTA (Next Linear Collider Test Accelerator) first chicane region is evaluated by simulation studies. It is demonstrated that the higher order fields of the chicane dipole magnet and the dipole corrector magnet (which is attached on the quadrupoles) are the main contributions for the emittance growth, especially for the case with a large initial emittance (γε 0 = 5 (micro)m for instance). These simulation results agree with the experimental observations.

  3. A combined emitter threat assessment method based on ICW-RCM

    Science.gov (United States)

    Zhang, Ying; Wang, Hongwei; Guo, Xiaotao; Wang, Yubing

    2017-08-01

    Considering that the tradition al emitter threat assessment methods are difficult to intuitively reflect the degree of target threaten and the deficiency of real-time and complexity, on the basis of radar chart method(RCM), an algorithm of emitter combined threat assessment based on ICW-RCM (improved combination weighting method, ICW) is proposed. The coarse sorting is integrated with fine sorting in emitter combined threat assessment, sequencing the emitter threat level roughly accordance to radar operation mode, and reducing task priority of the low-threat emitter; On the basis of ICW-RCM, sequencing the same radar operation mode emitter roughly, finally, obtain the results of emitter threat assessment through coarse and fine sorting. Simulation analyses show the correctness and effectiveness of this algorithm. Comparing with classical method of emitter threat assessment based on CW-RCM, the algorithm is visual in image and can work quickly with lower complexity.

  4. [The Herceptin® case : A case of falsification of medicinal products to a greater extent].

    Science.gov (United States)

    Streit, Renz

    2017-11-01

    Falsified medicines are a raising problem for the German drug market. The complex distribution channels across the European market facilitates the introduction of falsified and stolen medicines into the legal supply chain and may pose a risk for patients. The "Herceptin® case" from 2014 of falsified medicines of Italian origin demonstrates how complex distribution systems have been misused by criminal organizations in order to introduce stolen and thus falsified medicines via the parallel trade into the market, and which measures the authorities and the parallel-traders in the national and European network have taken to ensure patient safety. Falsified medicines will continue to be a problem in the future, so new monitoring systems have to be established and effectively used for prevention. The introduction of the EU-wide serialisation system in February 2019 is therefore intended to identify falsified drugs and to prevent the further trade as well as the expenditure to the patient. Furthermore, the maintenance and intensification of the cooperation between all EU authorities involved remains indispensable to close gateways in the distribution system for falsified medicines and to minimise the risk to the population.

  5. Lack of evidence for the presence of emerging HoBi-like viruses in North American fetal bovine serum lots.

    Science.gov (United States)

    The detection of HoBi-like virus in fetal bovine serum (FBS) labeled as United States of America (USA) origin, but packaged in Europe, raised concerns that HoBi-like virus may have entered the USA. In this study, 90 lots of FBS originating in North America (NA) were screened for pestivirus antigen ...

  6. New method for large scale production of medically applicable Actinium-225 and Radium-223

    International Nuclear Information System (INIS)

    Aliev, R.A.; Vasilyev, A.N.; Ostapenko, V.; Kalmykov, S.N.; Zhuikov, B.L.; Ermolaev, S.V.; Lapshina, E.V.

    2014-01-01

    Alpha-emitters ( 211 At, 212 Bi, 213 Bi, 223 Ra, 225 Ac) are promising for targeted radiotherapy of cancer. Only two alpha decays near a cell membrane result in 50% death of cancer cell and only a single decay inside the cell is required for this. 225 Ac may be used either directly or as a mother radionuclide in 213 Bi isotope generator. Production of 225 Ac is provided by three main suppliers - Institute for Transuranium Elements in Germany, Oak Ridge National Laboratory in USA and Institute of Physics and Power Engineering in Obninsk, Russia. The current worldwide production of 225 Ac is approximately 1.7 Ci per year that corresponds to only 100-200 patients that could be treated annually. The common approach for 225 Ac production is separation from mother 229 Th or irradiation of 226 Ra with protons in a cyclotron. Both the methods have some practical limitations to be applied routinely. 225 Ac can be also produced by irradiation of natural thorium with medium energy protons . Cumulative cross sections of 225 Ac, 227 Ac, 227 Th, 228 Th formations have been obtained recently. Thorium targets (1-9 g) were irradiated by 114-91 MeV proton beam (1-50 μA) at INR linear accelerator. After dissolution in 8 M HNO 3 + 0.004 M HF thorium was removed by double LLX by HDEHP in toluene (1:1). Ac and REE were pre-concentrated and separated from Ra and most fission products by DGA-Resin (Triskem). After washing out by 0.01 M HNO 3 Ac was separated from REE by TRU Resin (Triskem) in 3 M HNO 3 media. About 6 mCi 225 Ac were separated in hot cell with chemical yield 85%. The method may be upscaled for production of Ci amounts of the radionuclide. The main impurity is 227 Ac (0.1% at the EOB) but it does not hinder 225 Ac from being used for medical 225 Ac/ 213 Bi generators. (author)

  7. Measurements of Thermal Emittance for Cesium Telluride Photocathodes at PITZ

    CERN Document Server

    Miltchev, V; Grabosch, H J; Han, J H; Krasilnikov, M; Oppelt, A; Petrosian, B; Staykov, L; Stephan, F

    2005-01-01

    The thermal emittance determines the lower emittance limit and its measurement is of high importance to understand the ultimate injector performance. In this contribution we present results of thermal emittance measurements under rf operation conditions for various Cs2Te cathodes and different accelerating gradients. Measurements of thermal emittance scaling with the cathode laser spot size are presented and analysed. The significance of the Schottky effect in the emittance formation process is discussed.

  8. 19 CFR 213.1 - Purpose and applicability of part.

    Science.gov (United States)

    2010-04-01

    ... 213.1 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION INVESTIGATIONS OF UNFAIR PRACTICES IN IMPORT TRADE TRADE REMEDY ASSISTANCE § 213.1 Purpose and applicability of part. (a) Section 339 of... benefits available under the trade laws identified in § 213.2(b) and the procedures to be followed and...

  9. Electron emitter pulsed-type cylindrical IEC

    International Nuclear Information System (INIS)

    Miley, G.H.; Gu, Y.; Stubbers, R.; Zich, R.; Anderl, R.; Hartwell, J.

    1997-01-01

    A cylindrical version of the single grid Inertial Electrostatic Confinement (IEC) device (termed the C-device) has been developed for use as a 2.5-MeV D-D fusion neutron source for neutron activation analysis. The C-device employs a hollow-tube type cathode with similar anodes backed up by ''reflector'' dishes. The resulting discharge differs from a conventional hollow cathode discharge, by creating an explicit ion beam which is ''pinched'' in the cathode region. Resulting fusion reactions generate ∼10 6 neutron/s. A pulsed version is under development for applications requiring higher fluxes. Several pulsing techniques are under study, including an electron emitter (e-emitter) assisted discharge in a thorated tungsten wire emitter located behind a slotted area in the reflector dishes. Pulsing is initiated after establishing a low power steady-state discharge by pulsing the e-emitter current using a capacitor switch type circuit. The resulting electron jet, coupled with the discharge by the biased slot array, creates a strong pulse in the pinched ion beam. The pulse length/repetition rate are controlled by the e-emitter pulse circuit. Typical parameters in present studies are ∼30micros, 10Hz and 1-amp ion current. Corresponding neutron measurements are an In-foil type activation counter for time averaged rates. Results for a wide variety of operating conditions are presented

  10. Emittance and beam size distortion due to linear coupling

    International Nuclear Information System (INIS)

    Parzen, G.

    1993-01-01

    At injection, the presence of linear coupling may result in an increased beam emittance and in increased beam dimensions. Results for the emittance in the presence of linear coupling will be found. These results for the emittance distortion show that the harmonics of the skew quadrupole field close to ν x + ν y are the important harmonics. Results will be found for the important driving terms for the emittance distortion. It will be shown that if these driving terms are corrected, then the total emittance is unchanged, var-epsilon x + var-epsilon y = var-epsilon 1 + var-epsilon 2 . Also, the increase in the beam dimensions will be limited to a factor which is less than 1.414. If the correction is good enough, see below for details, one can achieve var-epsilon 1 = var-epsilon x , var-epsilon 2 = var-epsilon where var-epsilon 1 , var-epsilon 2 are the emittances in the presence of coupling, and the beam dimensions are unchanged. Global correction of the emittance and beam size distortion appears possible

  11. The Quantum Efficiency and Thermal Emittance of Metal Photocathodes

    International Nuclear Information System (INIS)

    Dowell, D.

    2009-01-01

    Modern electron beams have demonstrated the brilliance needed to drive free electron lasers at x-ray wavelengths, with the principle improvements occurring since the invention of the photocathode gun. The state-of-the-art normalized emittance electron beams are now becoming limited by the thermal emittance of the cathode. In both DC and RF photocathode guns, details of the cathode emission physics strongly influence the quantum efficiency and the thermal emittance. Therefore improving cathode performance is essential to increasing the brightness of beams. It is especially important to understand the fundamentals of cathode quantum efficiency and thermal emittance. This paper investigates the relationship between the quantum efficiency and the thermal emittance of metal cathodes using the Fermi-Dirac model for the electron distribution. We derive the thermal emittance and its relationship to the quantum efficiency, and compare our results to those of others

  12. Labelling of the platyhelminth dugesia tigrina with sup(99m) technetium

    International Nuclear Information System (INIS)

    Bernardo Filho, M.; Pires, E.T.; Boasquevisque, E.M.; Hasson-Voloch, A.

    1989-01-01

    The study of the labelling of planaria with sup(99m)Tc shows that the incorporation of radioactivity in this platyhelminth increases with an increase in SnCl sub(2) concentration from 0.13 to 1.3 μM, reaching a plateau in the range of 1.3-130 μM them decreasing with 1300 μM. At concentrations of 1.3 and 13 μM SnCl sub(2), a stronger binding of sup(99m)Tc was obtained. The biological viability of the labelled planaria was not altered when the described methodology was used. The advantage of this new labelling technique is that it is possible to obtain a platyhjelminth preparation labelled with a radionuclide that is very cheap, is easily available and is a gamma emitter with a photon energy of 140 KeV. (author)

  13. 7 CFR 1280.213 - Investment of funds.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Investment of funds. 1280.213 Section 1280.213 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... thereof, in any interest-bearing account or certificate of deposit of a financial institution that is a...

  14. The fluorodediazonation - a method for n.c.a.-18F-labelling of aromatic substrates

    International Nuclear Information System (INIS)

    Zwernemann, O.

    1991-06-01

    For the positron emission tomography (PET) applications, radiopharmaceuticals are required that are labelled with short-lived positron emitters. Fluorine-18 has become the leading radionuclide used for PET, due to its favourable physical properties. However, the labelling of aromatic substances with fluorine-18 with the methods available presents problems not encountered with aliphatic compounds. The decomposition of aromatic diazonium salts opens up feasible ways of preparing a broad range of labelled compounds. The dissertation investigated the possibilities of labelling with fluorine-18 by way of dediazonation on the standard substrate p-Toluidyl diazonium ion. The results reported show that the method of fluorodediazonation is an interesting further method for F-18 labelling of aromatic substrates in addition to the hitherto applied techniques. It allows carrier-free labelling of a large group of substances which cannot be fluorinated via direct nucleophilicity. (BBR) [de

  15. Cooperative spontaneous emission of nano-emitters with inter-emitter coupling in a leaky microcavity

    International Nuclear Information System (INIS)

    Hong, Suc-Kyoung; Nam, Seog Woo; Yang, Hyung Jin

    2015-01-01

    We study the spontaneous emission from a few two-level nano-emitters placed in a leaky microcavity with Lorentzian spectral density near a critically damped regime. Collective features of the spontaneous emission are investigated by numerical analysis of the excitation dynamics when initially one nano-emitter is totally excited but we do not know which one. The results show that there are three decay rates in the excitation dynamics, two for simple exponential decays and one for damped oscillatory decay. The excitation dynamics is found to critically depend on the regime of the system. It is shown that the spontaneous emission is enhanced or suppressed depending on whether the system is in the underdamped or overdamped regime, respectively. On the other hand, the cooperative spontaneous emission is suppressed in the underdamped while it is enhanced in the overdamped regime. Furthermore, the effect of the direct inter-emitter coupling on the breaking of the cooperativeness of the spontaneous emission is shown as well. (paper)

  16. Standard test of labelling efficiency for quality control of no carrier added 90YCl3

    International Nuclear Information System (INIS)

    Beran, M.; Eigner Henke, K.; Srank, J.; Melichar, F.

    2007-01-01

    Particle emitting radionuclides (e.g. beta-emitters 90 Y and 177 Lu, alpha-emitter 211 At, Auger electron emitter 165 Er or positron emitter 86 Y) are beeing more and more frequently used in research and clinical practice for imaging and targeted therapy in nuclear medicine. This radiometals, altogether three valent lanthanides or actinides with high specific radioactivity, coupled to biomolecule carriers (peptides or monoclonal antibodies) through chelating link (e.g. DTPA or DOTA) are targeted against specific antigens and receptors of diseased tissues in order to obtain their image or to cause their radiation ablation. The radionuclide precursor 90 YCl 3 (solution of hard β-emitter 90 Y in a diluted HCl) with high purity and specific activity is already commercially produced and successfully used in nuclear medicine, e.g. for radioimmunotherapy of Lymphoma. Specification and purity of our product obtained by extraction 90 Sr/ 90 Y generator (using technology of centrifuge extractors with di-2-ethylhexylphosphoric acid) is examined and compared to other similar products in this contribution. A standard method for determination of labelling efficiency of the precursor with DOTA Octreotide (DOTATATE) using ITLC/SG chromatography is also described and proposed for quality assesment. (Author)

  17. 25 CFR 213.33 - Diligence and prevention of waste.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Diligence and prevention of waste. 213.33 Section 213.33... LANDS OF MEMBERS OF FIVE CIVILIZED TRIBES, OKLAHOMA, FOR MINING Operations § 213.33 Diligence and prevention of waste. The lessee shall exercise diligence in drilling and operating wells for oil and gas on...

  18. 40 CFR 86.213-94 - Fuel specifications.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Fuel specifications. 86.213-94 Section 86.213-94 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... 1994 and Later Model Year Gasoline-Fueled New Light-Duty Vehicles, New Light-Duty Trucks and New Medium...

  19. 40 CFR 86.213-04 - Fuel specifications.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Fuel specifications. 86.213-04 Section 86.213-04 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... 1994 and Later Model Year Gasoline-Fueled New Light-Duty Vehicles, New Light-Duty Trucks and New Medium...

  20. 40 CFR 86.213-11 - Fuel specifications.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Fuel specifications. 86.213-11 Section 86.213-11 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... 1994 and Later Model Year Gasoline-Fueled New Light-Duty Vehicles, New Light-Duty Trucks and New Medium...

  1. AutoBD: Automated Bi-Level Description for Scalable Fine-Grained Visual Categorization.

    Science.gov (United States)

    Yao, Hantao; Zhang, Shiliang; Yan, Chenggang; Zhang, Yongdong; Li, Jintao; Tian, Qi

    Compared with traditional image classification, fine-grained visual categorization is a more challenging task, because it targets to classify objects belonging to the same species, e.g. , classify hundreds of birds or cars. In the past several years, researchers have made many achievements on this topic. However, most of them are heavily dependent on the artificial annotations, e.g., bounding boxes, part annotations, and so on . The requirement of artificial annotations largely hinders the scalability and application. Motivated to release such dependence, this paper proposes a robust and discriminative visual description named Automated Bi-level Description (AutoBD). "Bi-level" denotes two complementary part-level and object-level visual descriptions, respectively. AutoBD is "automated," because it only requires the image-level labels of training images and does not need any annotations for testing images. Compared with the part annotations labeled by the human, the image-level labels can be easily acquired, which thus makes AutoBD suitable for large-scale visual categorization. Specifically, the part-level description is extracted by identifying the local region saliently representing the visual distinctiveness. The object-level description is extracted from object bounding boxes generated with a co-localization algorithm. Although only using the image-level labels, AutoBD outperforms the recent studies on two public benchmark, i.e. , classification accuracy achieves 81.6% on CUB-200-2011 and 88.9% on Car-196, respectively. On the large-scale Birdsnap data set, AutoBD achieves the accuracy of 68%, which is currently the best performance to the best of our knowledge.Compared with traditional image classification, fine-grained visual categorization is a more challenging task, because it targets to classify objects belonging to the same species, e.g. , classify hundreds of birds or cars. In the past several years, researchers have made many achievements on this topic

  2. Diamondoid monolayers as electron emitters

    Science.gov (United States)

    Yang, Wanli [El Cerrito, CA; Fabbri, Jason D [San Francisco, CA; Melosh, Nicholas A [Menlo Park, CA; Hussain, Zahid [Orinda, CA; Shen, Zhi-Xun [Stanford, CA

    2012-04-10

    Provided are electron emitters based upon diamondoid monolayers, preferably self-assembled higher diamondoid monolayers. High intensity electron emission has been demonstrated employing such diamondoid monolayers, particularly when the monolayers are comprised of higher diamondoids. The application of such diamondoid monolayers can alter the band structure of substrates, as well as emit monochromatic electrons, and the high intensity electron emissions can also greatly improve the efficiency of field-effect electron emitters as applied to industrial and commercial applications.

  3. Nanodiamond Emitters of Single Photons

    Directory of Open Access Journals (Sweden)

    Vlasov I.I.

    2015-01-01

    Full Text Available Luminescence properties of single color centers were studied in nanodiamonds of different origin. It was found that single photon emitters could be realized even in molecularsized diamond (less than 2 nm capable of housing stable luminescent center “silicon-vacancy.” First results on incorporation of single-photon emitters based on luminescent nanodiamonds in plasmonic nanoantennas to enhance the photon count rate and directionality, diminish the fluorescence decay time, and provide polarization selectivity are presented.

  4. Tolerances for the vertical emittance in damping rings

    International Nuclear Information System (INIS)

    Raubenheimer, T.O.

    1991-11-01

    Future damping rings for linear colliders will need to have very small vertical emittances. In the limit of low beam current, the vertical emittance is primarily determined by the vertical dispersion and the betatron coupling. In this paper, the contributions to these effects from random misalignments are calculated and tolerances are derived to limit the vertical emittance with a 95% confidence level. 10 refs., 5 figs

  5. Beam emittance measurements on multicusp ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Sarstedt, M.; Lee, Y.; Leung, K.N. [and others

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 {mu}m patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma.

  6. Beam emittance measurements on multicusp ion sources

    International Nuclear Information System (INIS)

    Sarstedt, M.; Lee, Y.; Leung, K.N.

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 μm patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma

  7. 13 CFR 500.213 - Termination of obligations.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Termination of obligations. 500.213 Section 500.213 Business Credit and Assistance EMERGENCY OIL AND GAS GUARANTEED LOAN BOARD... the Application, the Guarantee or the Loan Documents; (5) A Lender fails to make a demand for payment...

  8. Test results on two thermionic converters with cermet emitters

    International Nuclear Information System (INIS)

    Saunders, M.; Danielson, L.; Huffman, F.

    1983-01-01

    An emitter made of a directionally solidified Mo-Al 2 O 3 , Cr 2 O 3 eutectic was provided by Eindhoven University of Technology in Eindhoven, The Netherlands. Although the high temperature braze cycle used in bonding this electrode to the emitter substrate destroyed its characteristic needle microstructure, the converter gave good performance. Apparently, chemical species evaporated from the emitter onto the collector provided a low collector work function. The resulting low barrier indices suggest that this surface is a promising emitter

  9. Synthesis of tritium-labelled (-)-U50,488, a selective kappa opioid agonist

    International Nuclear Information System (INIS)

    Thurkauf, A.; Costa, B. de; Rice, K.C.

    1989-01-01

    The preparation of 3 H labelled (-)-trans-3,4-dichloro-N-methyl-N[2-(1-pyrrolidinyl) cyclohexyl]benzeneacetamide (U50,488) in four steps from N-methylcyclohexylaziridine is described. The synthesis of the pharmacologically active (-) isomer of U50, 488 was accomplished through the resolution of the intermediate 2-[1-(3-pyrrolinyl)]-N-methylcyclohexylamine using (+)-mandelic acid. (Author)

  10. Transverse emittance growth in staged laser-wakefield acceleration

    Directory of Open Access Journals (Sweden)

    T. Mehrling

    2012-11-01

    Full Text Available We present a study on the emittance evolution of electron bunches, externally injected into laser-driven plasma waves using the three-dimensional particle-in-cell (PIC code OSIRIS. Results show order-of-magnitude transverse emittance growth during the injection process, if the electron bunch is not matched to its intrinsic betatron motion inside the wakefield. This behavior is supported by analytic theory reproducing the simulation data to a percent level. The length over which the full emittance growth develops is found to be less than or comparable to the typical dimension of a single plasma module in current multistage designs. In addition, the analytic theory enables the quantitative prediction of emittance degradation in two consecutive accelerators coupled by free-drift sections, excluding this as a scheme for effective emittance-growth suppression, and thus suggests the necessity of beam-matching sections between acceleration stages with fundamental implications on the overall design of staged laser-wakefield accelerators.

  11. Emittance measurements in Grumman 1 MeV beamline

    International Nuclear Information System (INIS)

    Debiak, T.; Gammel, G.; Melnychuk, S.

    1992-01-01

    The emittance of a 30 keV H - beam has been measured with an Allison type electrostatic analyser at two positions separated by 85 cm along the Grumman 1 MeV beamline LEBT at low currents (about 4 mA, no Cs 2 O additive in the source) and at higher currents (10-15 mA, with Cs 2 O additive in the source). No emittance growth was observed between the two positions, but, at the higher current level, the emittance was about 60% higher than at the low current level (Σ n ,rms = .0045 π cm-mrad vs. 0070 π cm-mrad). Argon was then introduced up to a partial pressure of 4x10 -5 torr, and the emittance decreased back to a range corresponding to that found at the lower currents. However, beam noise was observed at the downstream position, and there is evidence for a small amount of emittance growth (<20%) between the two positions

  12. Emittance Growth during Bunch Compression in the CTF-II

    Energy Technology Data Exchange (ETDEWEB)

    Raubenheimer, Tor O

    1999-02-26

    Measurements of the beam emittance during bunch compression in the CLIC Test Facility (CTF-II) are described. The measurements were made with different beam charges and different energy correlations versus the bunch compressor settings which were varied from no compression through the point of full compression and to over-compression. Significant increases in the beam emittance were observed with the maximum emittance occurring near the point of full (maximal) compression. Finally, evaluation of possible emittance dilution mechanisms indicate that coherent synchrotron radiation was the most likely cause.

  13. Electrohydrodynamic emitters of ion beams

    International Nuclear Information System (INIS)

    Dudnikov, V.G.; Shabalin, A.L.

    1990-01-01

    Physical processes determining generation of ion beams with high emission current density in electrohydrodynamic emitters are considered. Electrohydrodynamic effects developing in ion emission features and kinetics of ion interaction in beams with high density are discussed. Factors determining the size of the emission zone, emission stability at high and low currents, cluster generation, increase of energy spread and decrease of brightness are analyzed. Problems on practical provision of stable EHD emitter functioning are considered. 94 refs.; 8 figs.; 1 tab

  14. Emittance measurements in low energy ion storage rings

    Science.gov (United States)

    Hunt, J. R.; Carli, C.; Resta-López, J.; Welsch, C. P.

    2018-07-01

    The development of the next generation of ultra-low energy antiproton and ion facilities requires precise information about the beam emittance to guarantee optimum performance. In the Extra-Low ENergy Antiproton storage ring (ELENA) the transverse emittances will be measured by scraping. However, this diagnostic measurement faces several challenges: non-zero dispersion, non-Gaussian beam distributions due to effects of the electron cooler and various systematic errors such as closed orbit offsets and inaccurate rms momentum spread estimation. In addition, diffusion processes, such as intra-beam scattering might lead to emittance overestimates. Here, we present algorithms to efficiently address the emittance reconstruction in presence of the above effects, and present simulation results for the case of ELENA.

  15. Transverse emittance measurement and preservation at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Maria

    2016-06-20

    The Large Hadron Collider (LHC) at CERN is a high energy storage ring that provides proton and heavy ion collisions to study fundamental particle physics. The luminosity production is closely linked to emittance preservation in the accelerator. The transverse emittance is the phase space density of the beam and should be conserved when the particle beam is transformed through the accelerator. Perturbing effects, however, can lead to emittance increase and hence luminosity degradation. Measuring the emittance growth is a complex task with high intensity beams and changing energies. The machine optics and the transverse beam size have to be measured as accurately as possible. Beta function measurements with k-modulation are discussed. With this method the quadrupole focussing strength is varied and the resulting tune change is traced to determine the beta function at the quadrupole. A new k-modulation measurement tool was developed for the LHC. The fully automatic and online measurement system takes constraints of various systems such as tune measurement precision and powering limitations of the LHC superconducting circuits into account. With sinusoidal k-modulation record low beta function measurement uncertainties in the LHC have been reached. 2015 LHC beta function and β*, which is the beta function at the collision point, measurements with k-modulation will be presented. Wire scanners and synchrotron light monitors are presently used in the LHC to measure the transverse beam size. Accuracy and limitations of the LHC transverse profile monitors are discussed. During the 2012 LHC proton run it was found that wire scanner photomultiplier saturation added significant uncertainty on all measurements. A large discrepancy between emittances from wire scanners and luminosity was discovered but not solved. During Long Shutdown 1 the wire scanner system was upgraded with new photomultipliers. A thorough study of LHC wire scanner measurement precision in 2015 is presented

  16. Improvements in emittance wake field optimization for the SLAC Linear Collider

    CERN Document Server

    Decker, Franz Josef

    2003-01-01

    The transverse emittances in the SLAC Linear Collider can be severely diluted by collective wakefield effects and dispersion. For the 1997/98 SLC/SLD run important changes were implemented in the way the emittance is optimized. Early in the linac, where the energy spread is large due to BNS damping, the emittance growth is dominated by dispersion. In this regime emittance tuning bumps may introduce additional wakefield tails and their use is now avoided. At the end of the linac the energy spread is minimal and the emittance measurement is most sensitive to wakefield emittance dilution. In previous years, the emittances were tuned on wire scanners located near but not at the end of the linac (after about 90% of its length). Simulations show that emittance growth of up to 100% can occur in the remaining 10%. In this run wire scanners at the entrance of the Final Focus, the last place where the emittances can be measured, were used for the optimization. Screens at the end of the linac allow additional real time ...

  17. Field emission characteristics of a small number of carbon fiber emitters

    Directory of Open Access Journals (Sweden)

    Wilkin W. Tang

    2016-09-01

    Full Text Available This paper reports an experiment that studies the emission characteristics of small number of field emitters. The experiment consists of nine carbon fibers in a square configuration. Experimental results show that the emission characteristics depend strongly on the separation between each emitter, providing evidence of the electric field screening effects. Our results indicate that as the separation between the emitters decreases, the emission current for a given voltage also decreases. The authors compare the experimental results to four carbon fiber emitters in a linear and square configurations as well as to two carbon fiber emitters in a paired array. Voltage-current traces show that the turn-on voltage is always larger for the nine carbon fiber emitters as compared to the two and four emitters in linear configurations, and approximately identical to the four emitters in a square configuration. The observations and analysis reported here, based on Fowler-Nordheim field emission theory, suggest the electric field screening effect depends critically on the number of emitters, the separation between them, and their overall geometric configuration.

  18. Emittance calculations for the Stanford Linear Collider injector

    International Nuclear Information System (INIS)

    Sheppard, J.C.; Clendenin, J.E.; Helm, R.H.; Lee, M.J.; Miller, R.H.; Blocker, C.A.

    1983-03-01

    A series of measurements have been performed to determine the emittance of the high intensity, single bunch beam that is to be injected into the Stanford Linear Collider. On-line computer programs were used to control the Linac for the purpose of data acquisition and to fit the data to a model in order to deduce the beam emittance. This paper will describe the method of emittance calculation and present some of the measurement results

  19. Beam emittance measurement from CERN thermionic guns

    International Nuclear Information System (INIS)

    Kester, O.; Rao, R.; Rinolfi, L.

    1992-01-01

    In the LEP Injector Linacs (LIL) a thermionic gun provides electron beams with different peak intensities at an energy of 80 keV. The beam emittances were estimated from the EGUN programme. Since the gun is of triode type, the main contribution to the emittance comes from the grid. The simulation programme does not model the real geometry by assuming a cylindrical symmetry, while the grid does not have such symmetry. A Gun Test Facility (GTF), allowing emittance measurements, based on the 3-gradients-method was installed. The experimental results are presented. (author) 6 refs.; 6 figs

  20. Multi-dimensional beam emittance and β-functions

    International Nuclear Information System (INIS)

    Buon, J.

    1993-05-01

    The concept of r.m.s. emittance is extended to the case of several degrees of freedom that are coupled. That multi-dimensional emittance is lower than the product of the emittances attached to each degree of freedom, but is conserved in a linear motion. An envelope-hyperellipsoid is introduced to define the β-functions of the beam envelope. On the contrary of an one-degree of freedom motion, it is emphasized that these envelope functions differ from the amplitude functions of the normal modes of motion as a result of the difference between the Liouville and Lagrange invariants. (author) 4 refs

  1. Beam phase space and emittance

    International Nuclear Information System (INIS)

    Buon, J.

    1992-02-01

    The classical and elementary results for canonical phase space, the Liouville theorem and the beam emittance are reviewed. Then, the importance of phase portraits to obtain a geometrical description of motion is emphasized, with examples in accelerator physics. Finally, a statistical point of view is used to define beam emittance, to study its law of approximate conservation, with three particular examples, and to introduce a beam envelope-ellipse and the β-function, emphasing the statistical features of its properties. (author) 14 refs.; 11 figs

  2. Combustion powered thermophotovoltaic emitter system

    Energy Technology Data Exchange (ETDEWEB)

    McHenry, R.S. [Naval Academy, Annapolis, MD (United States). Naval Architecture, Ocean and Marine Engineering

    1995-07-01

    The US Naval Academy (USNA) has recently completed an engineering design project for a high temperature thermophotovoltaic (TPV) photon emitter. The final apparatus was to be portable, completely self contained, and was to incorporate cycle efficiency optimization such as exhaust stream recuperation. Through computer modeling and prototype experimentation, a methane fueled emitter system was designed from structural ceramic materials to fulfill the high temperature requirements necessary for high system efficiency. This paper outlines the engineering design process, discusses obstacles and solutions encountered, and presents the final design.

  3. Coupling single emitters to quantum plasmonic circuits

    DEFF Research Database (Denmark)

    Huck, Alexander; Andersen, Ulrik Lund

    2016-01-01

    In recent years, the controlled coupling of single-photon emitters to propagating surface plasmons has been intensely studied, which is fueled by the prospect of a giant photonic nonlinearity on a nanoscaled platform. In this article, we will review the recent progress on coupling single emitters...

  4. 3D study of a bi facial polycrystalline photovoltaic cell under constant magnetic field and determination of the parameters of recombination from internal quantum yield

    International Nuclear Information System (INIS)

    ZOUMA Bernard

    2010-01-01

    The work presented in this thesis deals with the problem of the quality of polycrystalline silicon solar cells. This work has been done on square surface columnar grains of the bi facial solar cell. This study ends in the determination of the quality of bi facial solar cells from their recombination parameters. We propose an useful technique to determine these recombination parameters from the algorithm calculation that is based on the internal quantum efficiency. A set of dimensional approach like the three-dimensional model of the solar cell that allows taking into account the grain size and grain boundaries recombination velocity. The emitter contribution and the terrestrial magnetic field influence are taken into account too. While lighted, the emitter region becomes a recombination zone of the electron from the base region. We have obtained a new exhaustive analytical expression of the internal quantum efficiency. This theoretical efficiency is a function of the recombination parameters and it is used to fit the experimental curves of the internal quantum efficiency versus the wavelength. The results are in a good agreement with the experimental values.(Author) [fr

  5. Structure and physical properties of the LaBiFe{sub 2}O{sub 6} Perovskite produced by the modified Pechini method

    Energy Technology Data Exchange (ETDEWEB)

    Palacio, Johny Andrés Jaramillo; Bello, Elixir William Barrera; Landínez-Téllez, David A.; Roa-Rojas, Jairo, E-mail: jroar@unal.edu.com [Grupo de Física de Nuevos Materiales, Universidad Nacional de Colombia, Bogotá DC (Colombia); Cagigas, Julián Andrés Munévar [Laboratory for Muon Spin Spectroscopy, Paul Scherrer Institut (Switzerland); Arnache, Oscar [Grupo de Estado Sólido, Universidad de Antioquia, Medellín (Colombia)

    2017-10-15

    In this paper the synthesis of the LaBiFe{sub 2}O{sub 6} material by the modified Pechini method is reported. Structural, morphologic, magnetic and optic experimental studies were performed. Rietveld refinement of x-ray diffraction patterns revealed that LaBiFe{sub 2}O{sub 6} crystallizes in an orthorhombic perovskite structure (space group Pnma, ⧣ 62). Scanning electron microscopy images showed the nanometric feature of grains. X-ray dispersive spectroscopy permitted to infer the obtaining of the LaBiFe{sub 2}O{sub 6} expected stoichiometry. Results of magnetic susceptibility as a function of temperature and field magnetization evidenced mixed ferromagnetism and superparamagnetism behavior at T=300 K. Mössbauer spectroscopy supported the superparamagnetic and ferromagnetic responses as a result of the nanogranular morphology and anisotropy effects. Spectrum of diffuse reflectance suggest that this material behaves as a semiconductor with energy gap E{sub g} =2.13 eV. (author)

  6. Dynamics of tropomyosin in muscle fibers as monitored by saturation transfer EPR of bi-functional probe.

    Directory of Open Access Journals (Sweden)

    Roni F Rayes

    Full Text Available The dynamics of four regions of tropomyosin was assessed using saturation transfer electron paramagnetic resonance in the muscle fiber. In order to fully immobilize the spin probe on the surface of tropomyosin, a bi-functional spin label was attached to i,i+4 positions via cysteine mutagenesis. The dynamics of bi-functionally labeled tropomyosin mutants decreased by three orders of magnitude when reconstituted into "ghost muscle fibers". The rates of motion varied along the length of tropomyosin with the C-terminus position 268/272 being one order of magnitude slower then N-terminal domain or the center of the molecule. Introduction of troponin decreases the dynamics of all four sites in the muscle fiber, but there was no significant effect upon addition of calcium or myosin subfragment-1.

  7. Theory and measurements of emittance preservation in plasma wakefield acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Frederico, Joel

    2016-12-01

    In this dissertation, we examine the preservation and measurement of emittance in the plasma wakefield acceleration blowout regime. Plasma wakefield acceleration (PWFA) is a revolutionary approach to accelerating charged particles that has been demonstrated to have the potential for gradients orders of magnitude greater than traditional approaches. The application of PWFA to the design of a linear collider will make new high energy physics research possible, but the design parameters must first be shown to be competitive with traditional methods. Emittance preservation is necessary in the design of a linear collider in order to maximize luminosity. We examine the conditions necessary for circular symmetry in the PWFA blowout regime, and demonstrate that current proposals meet these bounds. We also present an application of beam lamentation which describes the process of beam parameter and emittance matching. We show that the emittance growth saturates as a consequence of energy spread in the beam. The initial beam parameters determine the amount of emittance growth, while the contribution of energy spread is negligible. We also present a model for ion motion in the presence of a beam that is much more dense than the plasma. By combining the model of ion motion and emittance growth, we find the emittance growth due to ion motion is minimal in the case of marginal ion motion. In addition, we present a simulation that validates the ion motion model, which is under further development to examine emittance growth of both marginal and pronounced ion motion. Finally, we present a proof-of-concept of an emittance measurement which may enable the analysis of emittance preservation in future PWFA experiments.

  8. Relative biological effectiveness of alpha-particle emitters in vivo at low doses

    International Nuclear Information System (INIS)

    Howell, R.W.; Azure, M.T.; Narra, V.R.; Rao, D.V.

    1994-01-01

    The therapeutic potential of radionuclides that emit α particles, as well as their associated health hazards, have attracted considerable attention. The 224 Ra daughters 212 Pb and 212 Bi, by virtue of their radiation properties which involve emission of α and β particles in their decay to stable 208 Pb, have been proposed as candidates for radioimmunotherapy. Using mouse testes as the experimental model and testicular spermhead survival as the biological end point, the present work examines the radiotoxicity of 212 Pb and its daughters. When 212 Pb, in equilibrium with its daughters 212 Bi, 212 Po and 208 Tl, was administered directly into the testis, the dose required to achieve 37% survival (D 37 ) was 0.143 ± 0.014 Gy and the corresponding RBE of the mixed radiation field was 4.7 when compared to the D 37 for acute external 120 kVp X rays. This datum, in conjunction with our earlier results for 210 Po, was used to obtain an RBE-LET relationship for α particles emitted by tissue-incorporated radionuclides: RBE α = 4.8 - 6.1 x 10 -2 LET + 1.0 x 10 -3 LET 2 . Similarly, the dependence of RBE on α-particle energy E α was given by RBE α = 22 E α -0.73 . These relationships, based on in vivo experimental data, may be valuable in predicting biological effects of α-particle emitters. 46 refs., 6 figs

  9. Measurement of transverse emittance in the Fermilab booster

    Energy Technology Data Exchange (ETDEWEB)

    Graves, William Sproull [Wisconsin U., Madison

    1994-01-01

    A new beam profile monitor has been built and installed in the Fermilab Booster synchrotron. It nondestructively measures the beam's vertical density distribution on a fast turn-by-turn basis. This enables one to measure the beam's transverse emittance and to observe emittance growth as it occurs. For high intensities (>2 times 10^{12 } protons), the normalized 95% emittance was observed to grow from 6pi mm-mrad at injection to 16pi mm-mrad at extraction. The initial (<5 msec) emittance growth and beam losses are shown to be caused by the space charge tune shift onto integer and 1/2 integer resonance lines. The growth near injection accounts for approximately 40% of the observed emittance increase throughout the acceleration cycle. The remaining 60% is due to two factors: slow linear growth due to betatron-motion driven by noise in the rf system; and faster growth after the transition energy that is caused by coupling of the longitudinal beam motion into the transverse planes.

  10. Electromagnetic compatibility of implantable neurostimulators to RFID emitters.

    Science.gov (United States)

    Pantchenko, Oxana S; Seidman, Seth J; Guag, Joshua W; Witters, Donald M; Sponberg, Curt L

    2011-06-09

    The objective of this study is to investigate electromagnetic compatibility (EMC) of implantable neurostimulators with the emissions from radio frequency identification (RFID) emitters. Six active implantable neurostimulators with lead systems were tested for susceptibility to electromagnetic fields generated by 22 RFID emitters. These medical devices have been approved for marketing in the U.S. for a number of intended uses that include: epilepsy, depression, incontinence, Parkinsonian tremor and pain relief. Each RFID emitter had one of the following carrier frequencies: 125 kHz, 134 kHz, 13.56 MHz, 433 MHz, 915 MHz and 2.45 GHz. The test results showed the output of one of the implantable neurostimulators was inhibited by 134 kHz RFID emitter at separation distances of 10 cm or less. The output of the same implantable neurostimulator was also inhibited by another 134 kHz RFID emitter at separation distances of 10 cm or less and also showed inconsistent pulsing rate at a separation distance of 15 cm. Both effects occurred during and lasted through out the duration of the exposure. The clinical significance of the effects was assessed by a clinician at the U.S. Food and Drug Administration. The effects were determined to be clinically significant only if they occurred for extended period of time. There were no observed effects from the other 5 implantable neurostimulators or during exposures from other RFID emitters.

  11. Relating Sequent Calculi for Bi-intuitionistic Propositional Logic

    Directory of Open Access Journals (Sweden)

    Luís Pinto

    2011-01-01

    Full Text Available Bi-intuitionistic logic is the conservative extension of intuitionistic logic with a connective dual to implication. It is sometimes presented as a symmetric constructive subsystem of classical logic. In this paper, we compare three sequent calculi for bi-intuitionistic propositional logic: (1 a basic standard-style sequent calculus that restricts the premises of implication-right and exclusion-left inferences to be single-conclusion resp. single-assumption and is incomplete without the cut rule, (2 the calculus with nested sequents by Gore et al., where a complete class of cuts is encapsulated into special "unnest" rules and (3 a cut-free labelled sequent calculus derived from the Kripke semantics of the logic. We show that these calculi can be translated into each other and discuss the ineliminable cuts of the standard-style sequent calculus.

  12. Spherical proton emitters

    International Nuclear Information System (INIS)

    Berg, S.; Semmes, P.B.; Nazarewicz, W.

    1997-01-01

    Various theoretical approaches to proton emission from spherical nuclei are investigated, and it is found that all the methods employed give very similar results. The calculated decay widths are found to be qualitatively insensitive to the parameters of the proton-nucleus potential, i.e., changing the potential parameters over a fairly large range typically changes the decay width by no more than a factor of ∼3. Proton half-lives of observed heavy proton emitters are, in general, well reproduced by spherical calculations with the spectroscopic factors calculated in the independent quasiparticle approximation. The quantitative agreement with experimental data obtained in our study requires that the parameters of the proton-nucleus potential be chosen carefully. It also suggests that deformed proton emitters will provide invaluable spectroscopic information on the angular momentum decomposition of single-proton orbitals in deformed nuclei. copyright 1997 The American Physical Society

  13. Self-powered detectors with thulium emitter

    International Nuclear Information System (INIS)

    Haller, P.; Klar, E.

    1978-01-01

    In addition to fission chambers, prompt-indicating self-powered (SPN) detectors are used for measuring the neutron flux density in the core of power reactors. Although current SPN detectors with a cobalt emitter give satisfactora results, detectors with other emitter materials have been analyzed and tested. The author describes the properties and decay pattern of the nuclide thulium and presents the results of measurements made while testing thulium detectors. (orig.) [de

  14. Localization of Narrowband Single Photon Emitters in Nanodiamonds.

    Science.gov (United States)

    Bray, Kerem; Sandstrom, Russell; Elbadawi, Christopher; Fischer, Martin; Schreck, Matthias; Shimoni, Olga; Lobo, Charlene; Toth, Milos; Aharonovich, Igor

    2016-03-23

    Diamond nanocrystals that host room temperature narrowband single photon emitters are highly sought after for applications in nanophotonics and bioimaging. However, current understanding of the origin of these emitters is extremely limited. In this work, we demonstrate that the narrowband emitters are point defects localized at extended morphological defects in individual nanodiamonds. In particular, we show that nanocrystals with defects such as twin boundaries and secondary nucleation sites exhibit narrowband emission that is absent from pristine individual nanocrystals grown under the same conditions. Critically, we prove that the narrowband emission lines vanish when extended defects are removed deterministically using highly localized electron beam induced etching. Our results enhance the current understanding of single photon emitters in diamond and are directly relevant to fabrication of novel quantum optics devices and sensors.

  15. Innovative energy efficient low-voltage electron beam emitters

    International Nuclear Information System (INIS)

    Felis, Kenneth P.; Avnery, Tovi; Berejka, Anthony J.

    2002-01-01

    Advanced electron beams (AEB) has developed a modular, low voltage (80-125 keV), high beam current (up to 40 ma), electron emitter with typically 25 cm of beam width, that is housed in an evacuated, returnable chamber that is easy to plug in and connect. The latest in nanofabrication enables AEB to use an ultra-thin beam window. The power supply for AEB's emitter is based on solid-state electronics. This combination of features results in a remarkable electrical efficiency. AEB's electron emitter relies on a touch screen, computer control system. With 80 μm of unit density beam penetration, AEB's electron emitter has gained market acceptance in the curing of opaque, pigmented inks and coatings used on flexible substrates, metals and fiber composites and in the curing of adhesives in foil based laminates

  16. Innovative energy efficient low-voltage electron beam emitters

    Science.gov (United States)

    Felis, Kenneth P.; Avnery, Tovi; Berejka, Anthony J.

    2002-03-01

    Advanced electron beams (AEB) has developed a modular, low voltage (80-125 keV), high beam current (up to 40 ma), electron emitter with typically 25 cm of beam width, that is housed in an evacuated, returnable chamber that is easy to plug in and connect. The latest in nanofabrication enables AEB to use an ultra-thin beam window. The power supply for AEB's emitter is based on solid-state electronics. This combination of features results in a remarkable electrical efficiency. AEB's electron emitter relies on a touch screen, computer control system. With 80 μm of unit density beam penetration, AEB's electron emitter has gained market acceptance in the curing of opaque, pigmented inks and coatings used on flexible substrates, metals and fiber composites and in the curing of adhesives in foil based laminates.

  17. Evaluations of carbon nanotube field emitters for electron microscopy

    Science.gov (United States)

    Nakahara, Hitoshi; Kusano, Yoshikazu; Kono, Takumi; Saito, Yahachi

    2009-11-01

    Brightness of carbon nanotube (CNT) emitters was already reported elsewhere. However, brightness of electron emitter is affected by a virtual source size of the emitter, which strongly depends on electron optical configuration around the emitter. In this work, I- V characteristics and brightness of a CNT emitter are measured under a practical field emission electron gun (e-gun) configuration to investigate availability of CNT for electron microscopy. As a result, it is obtained that an emission area of MWNT is smaller than its tip surface area, and the emission area corresponds to a five-membered-ring with 2nd nearest six-membered-rings on the MWNT cap surface. Reduced brightness of MWNT is measured as at least 2.6×109 A/m 2 sr V. It is concluded that even a thick MWNT has enough brightness under a practical e-gun electrode configuration and suitable for electron microscopy.

  18. Very bright, near-infrared single photon emitters in diamond

    Directory of Open Access Journals (Sweden)

    D. W. M. Lau

    2013-09-01

    Full Text Available We demonstrate activation of bright diamond single photon emitters in the near infrared range by thermal annealing alone, i.e., without ion implantation. The activation is crucially dependent on the annealing ambient. The activation of the single photon emitters is only observed when the sample is annealed in forming gas (4% H2 in Ar above temperatures of 1000 °C. By contrast, no emitters are activated by annealing in vacuum, oxygen, argon or deuterium. The emitters activated by annealing in forming gas exhibit very bright emission in the 730-760 nm wavelength range and have linewidths of ∼1.5-2.5 nm at room temperature.

  19. Measurement of emittance of metal interface in molten salt

    International Nuclear Information System (INIS)

    Araki, N.; Makino, A.; Nakamura, Y.

    1995-01-01

    A new technique for measuring the total normal emittance of a metal in a semi-transparent liquid has been proposed and this technique has been applied to measure the emittance of stainless steel (SUS304), nickel, and gold in molten potassium nitrate KNO 3 . These emittance data are indispensable to analyzing the radiative heat transfer between a metal and a semitransparent liquid, such as a molten salt

  20. Boundary conditions on the plasma emitter surface in the presence of a particle counter flow: I. Ion emitter

    Energy Technology Data Exchange (ETDEWEB)

    Astrelin, V. T., E-mail: V.T.Astrelin@inp.nsk.su; Kotelnikov, I. A. [Russian Academy of Sciences, Budker Institute of Nuclear Physics, Siberian Branch (Russian Federation)

    2017-02-15

    Emission of positively charged ions from a plasma emitter irradiated by a counterpropagating electron beam is studied theoretically. A bipolar diode with a plasma emitter in which the ion temperature is lower than the electron temperature and the counter electron flow is extracted from the ion collector is calculated in the one-dimensional model. An analog of Bohm’s criterion for ion emission in the presence of a counterpropagating electron beam is derived. The limiting density of the counterpropagating beam in a bipolar diode operating in the space-charge-limited-emission regime is calculated. The full set of boundary conditions on the plasma emitter surface that are required for operation of the high-current optics module in numerical codes used to simulate charged particle sources is formulated.

  1. Stability of rhenium-188 labeled antibody

    International Nuclear Information System (INIS)

    Lim, B. K.; Jung, J. M.; Jung, J. K.; Lee, D. S.; Lee, M. C.

    1999-01-01

    For clinical application of beta-emitter labeled antibody, high specific activity is important. Carrier-free Re-188 from W-188/Re-188 generator is an ideal radionuclide for this purpose. However, low stability of Re-188 labeled antibody, especially in high specific activity, due to radiolytic decomposition by high energy (2.1 MeV) beta ray was problem. We studied the stability of Re-188 labeled antibody, and stabilizing effect of several nontoxic radical-quenching agents. Pre-reduced monoclonal antibody (CEA79.4) was labeled with Re-188 by incubating with generator-eluted Re-188-perrhenate in the presence of stannous tartrate for 2 hr at room temperature. Radiochemical purity of each preparation was determined by chromatography (ITLC-SG/acetone, ITLC-SG/Umezawa, Whatman No.1/saline). Human serum albumin was added to the labeled antibodies(2%). Stability of Re-188-CEA79.4 was investigated in the presence of vitamin C, ethanol, or Tween 80 as radical-quenching agents. Specific activities of 4.29∼5.11 MBq/μg were obtained. Labeling efficiencies were 88±4%(n=12). Very low stability after removal of stannous tartrate from the preparation was observed. If stored after purging with N 2 , all the preparations were stable for 10 hr. However, if contacted with air, stability decreased. Perrhenate and Re-188-tartrate was major impurity in declined preparation (12∼47 and 9∼38% each, after 10 hr). Colloid-formation was not a significant problem in all cases. Addition of vitamin C stabilized the labeled antibodies either under N 2 or under air by reducing the formation of perrhenate. High specific activity Re-188 labeled antibody is unstable, especially, in the presence of oxygen. Addition of vitamin C increased the stability

  2. 22 CFR 1203.735-213 - Recommendations for employment.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Recommendations for employment. 1203.735-213 Section 1203.735-213 Foreign Relations UNITED STATES INTERNATIONAL DEVELOPMENT COOPERATION AGENCY EMPLOYEE... investigate applicants for employment. A principal officer in answer to a letter of inquiry from outside the U...

  3. Electromagnetic compatibility of implantable neurostimulators to RFID emitters

    Directory of Open Access Journals (Sweden)

    Guag Joshua W

    2011-06-01

    Full Text Available Abstract Background The objective of this study is to investigate electromagnetic compatibility (EMC of implantable neurostimulators with the emissions from radio frequency identification (RFID emitters. Methods Six active implantable neurostimulators with lead systems were tested for susceptibility to electromagnetic fields generated by 22 RFID emitters. These medical devices have been approved for marketing in the U.S. for a number of intended uses that include: epilepsy, depression, incontinence, Parkinsonian tremor and pain relief. Each RFID emitter had one of the following carrier frequencies: 125 kHz, 134 kHz, 13.56 MHz, 433 MHz, 915 MHz and 2.45 GHz Results The test results showed the output of one of the implantable neurostimulators was inhibited by 134 kHz RFID emitter at separation distances of 10 cm or less. The output of the same implantable neurostimulator was also inhibited by another 134 kHz RFID emitter at separation distances of 10 cm or less and also showed inconsistent pulsing rate at a separation distance of 15 cm. Both effects occurred during and lasted through out the duration of the exposure. Conclusions The clinical significance of the effects was assessed by a clinician at the U.S. Food and Drug Administration. The effects were determined to be clinically significant only if they occurred for extended period of time. There were no observed effects from the other 5 implantable neurostimulators or during exposures from other RFID emitters.

  4. Emittance growth and tune spectra at PETRA III

    International Nuclear Information System (INIS)

    Wanzenberg, R.

    2011-08-01

    At DESY the PETRA ring has been converted into a synchrotron radiation facility, called PETRA III. 20 damping wigglers have been installed to achieve an emittance of 1 nm. The commissioning with beam started in April 2009 and user runs have been started in 2010. The design current is 100 mA and the bunch to bunch distance is 8 ns for one particular filling pattern with 960 bunches. At a current of about 50 mA a strong vertical emittance increase has been observed. During machine studies it was found that the emittance increase depends strongly on the bunch filling pattern. For the user operation a filling scheme has been found which mitigates the increase of the vertical emittance. In August 2010 PETRA III has been operated without damping wigglers for one week. The vertical emittance growth was not significantly smaller without wigglers. Furthermore tune spectra at PETRA III show characteristic lines which have been observed at other storage rings in the connection with electron clouds. Measurements at PETRA III are presented for different bunch filling patterns and with and without wiggler magnets. (orig.)

  5. A polarization-insensitive plasmonic photoconductive terahertz emitter

    KAUST Repository

    Li, Xurong

    2017-11-16

    We present a polarization-insensitive plasmonic photoconductive terahertz emitter that uses a two-dimensional array of nanoscale cross-shaped apertures as the plasmonic contact electrodes. The geometry of the cross-shaped apertures is set to maximize optical pump absorption in close proximity to the contact electrodes. The two-dimensional symmetry of the cross-shaped apertures offers a polarization-insensitive interaction between the plasmonic contact electrodes and optical pump beam. We experimentally demonstrate a polarization-insensitive terahertz radiation from the presented emitter in response to a femtosecond optical pump beam and similar terahertz radiation powers compared to previously demonstrated polarization-sensitive photoconductive emitters with plasmonic contact electrode gratings at the optimum optical pump polarization.

  6. Emittance measurement for high-brightness electron guns

    International Nuclear Information System (INIS)

    Kobayashi, H.; Kurihara, T.; Sato, I.; Asami, A.; Yamazaki, Y.; Otani, S.; Ishizawa, Y.

    1992-01-01

    An emittance measurement system based on a high-precision pepper-pot technique has been developed for electron guns with low emittance of around πmm-mrad. Electron guns with a 1 mmφ cathode, the material of which is impregnated tungsten or single-crystal lanthanum hexaboride (La 1-x Ce x )B 6 , have been developed. The performance has been evaluated by putting stress on cathode roughness, which gives rise to an angular divergence, according to the precise emittance measurement system. A new type of cathode holder, which is a modified version of the so called Vogel type, was developed and the beam uniformity has been improved. (Author) 5 figs., tab., 9 refs

  7. 22 CFR 213.21 - Employee salary offset-general.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Employee salary offset-general. 213.21 Section... § 213.21 Employee salary offset—general. (a) Purpose. This section establishes USAID's policies and... account of an employee. (b) Scope. The provisions of this section apply to collection by salary offset...

  8. Evaluations of carbon nanotube field emitters for electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Nakahara, Hitoshi, E-mail: nakahara@nagoya-u.jp [Department of Quantum Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Kusano, Yoshikazu; Kono, Takumi; Saito, Yahachi [Department of Quantum Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan)

    2009-11-30

    Brightness of carbon nanotube (CNT) emitters was already reported elsewhere. However, brightness of electron emitter is affected by a virtual source size of the emitter, which strongly depends on electron optical configuration around the emitter. In this work, I-V characteristics and brightness of a CNT emitter are measured under a practical field emission electron gun (e-gun) configuration to investigate availability of CNT for electron microscopy. As a result, it is obtained that an emission area of MWNT is smaller than its tip surface area, and the emission area corresponds to a five-membered-ring with 2nd nearest six-membered-rings on the MWNT cap surface. Reduced brightness of MWNT is measured as at least 2.6x10{sup 9} A/m{sup 2} sr V. It is concluded that even a thick MWNT has enough brightness under a practical e-gun electrode configuration and suitable for electron microscopy.

  9. Few emitters in a cavity: from cooperative emission to individualization

    International Nuclear Information System (INIS)

    Auffeves, A; Portolan, S; Gerace, D; Drezet, A; Franca Santos, M

    2011-01-01

    We study the temporal correlations of the field emitted by an electromagnetic resonator coupled to a mesoscopic number of two-level emitters that are incoherently pumped by a weak external drive. We solve the master equation of the system for increasing number of emitters and as a function of the cavity quality factor, and we identify three main regimes characterized by well-distinguished statistical properties of the emitted radiation. For small cavity decay rates, the emission events are uncorrelated and the number of photons in the emitted field becomes larger than one, resembling the build-up of a laser field inside the cavity. At intermediate decay rates (as compared with the emitter-cavity coupling) and for a few emitters, the statistics of the emitted radiation is bunched and strikingly dependent on the parity of the number of emitters. The latter property is related to the cooperativity of the emitters mediated by their coupling to the cavity mode, and its connection with steady-state subradiance is discussed. Finally, in the bad cavity regime the typical situation of emission from a collection of individual emitters is recovered. We also analyze how the cooperative behavior evolves as a function of pure dephasing, which allows us to recover the case of a classical source made of an ensemble of independent emitters, similar to what is obtained for a very leaky cavity. State-of-the-art techniques of Q-switch of resonant cavities, allied with the recent capability of tuning single emitters in and out of resonance, suggest this system to be a versatile source of different quantum states of light.

  10. Few emitters in a cavity: from cooperative emission to individualization

    Energy Technology Data Exchange (ETDEWEB)

    Auffeves, A; Portolan, S [CEA/CNRS/UJF Joint Team ' Nanophysics and Semiconductors' , Institut Neel-CNRS, BP 166, 25 Rue des Martyrs, 38042 Grenoble Cedex 9 (France); Gerace, D [Dipartimento di Fisica ' Alessandro Volta' and UdR CNISM, Universita di Pavia, via Bassi 6, 27100 Pavia (Italy); Drezet, A [Institut Neel-CNRS, BP 166, 25 Rue des Martyrs, 38042 Grenoble Cedex 9 (France); Franca Santos, M, E-mail: msantos@fisica.ufmg.br [Departamento de Fisica, Universidade Federal de Minas Gerais, Belo Horizonte, CP 702, 30123-970 (Brazil)

    2011-09-15

    We study the temporal correlations of the field emitted by an electromagnetic resonator coupled to a mesoscopic number of two-level emitters that are incoherently pumped by a weak external drive. We solve the master equation of the system for increasing number of emitters and as a function of the cavity quality factor, and we identify three main regimes characterized by well-distinguished statistical properties of the emitted radiation. For small cavity decay rates, the emission events are uncorrelated and the number of photons in the emitted field becomes larger than one, resembling the build-up of a laser field inside the cavity. At intermediate decay rates (as compared with the emitter-cavity coupling) and for a few emitters, the statistics of the emitted radiation is bunched and strikingly dependent on the parity of the number of emitters. The latter property is related to the cooperativity of the emitters mediated by their coupling to the cavity mode, and its connection with steady-state subradiance is discussed. Finally, in the bad cavity regime the typical situation of emission from a collection of individual emitters is recovered. We also analyze how the cooperative behavior evolves as a function of pure dephasing, which allows us to recover the case of a classical source made of an ensemble of independent emitters, similar to what is obtained for a very leaky cavity. State-of-the-art techniques of Q-switch of resonant cavities, allied with the recent capability of tuning single emitters in and out of resonance, suggest this system to be a versatile source of different quantum states of light.

  11. Emittance formula for slits and pepper-pot measurement

    International Nuclear Information System (INIS)

    Zhang, M.

    1996-10-01

    In this note, a rigid formula for slits and pepper-pot emittance measurement is derived. The derivation is based on the one- dimensional slit measurement setup. A mathematical generalization of the slit emittance formula to the pepper-pot measurement is discussed

  12. MEV Energy Electrostatic Accelerator Ion Beam Emittance Measurement

    OpenAIRE

    I.G. Ignat’ev; M.I. Zakharets; S.V. Kolinko; D.P. Shulha

    2014-01-01

    The testing equipment was designed, manufactured and tried out permitting measurements of total current, current profile and emittance of an ion beam extracted from the ion beam. MeV energy electrostatic accelerator ion H + beam emittance measurement results are presented.

  13. Alpha-emitters for medical therapy workshop

    International Nuclear Information System (INIS)

    Feinendegen, L.E.; McClure, J.J.

    1996-01-01

    A workshop on ''Alpha-Emitters for Medical Therapy'' was held May 30-31, 1996 in Denver Colorado to identify research goals and potential clinical needs for applying alpha-particle emitters and to provide DOE with sufficient information for future planning. The workshop was attended by 36 participants representing radiooncology, nuclear medicine, immunotherapy, radiobiology, molecular biology, biochemistry, radiopharmaceutical chemistry, dosimetry, and physics. This report provides a summary of the key points and recommendations arrived at during the conference

  14. Alpha-emitters for medical therapy workshop

    Energy Technology Data Exchange (ETDEWEB)

    Feinendegen, L.E.; McClure, J.J.

    1996-12-31

    A workshop on ``Alpha-Emitters for Medical Therapy`` was held May 30-31, 1996 in Denver Colorado to identify research goals and potential clinical needs for applying alpha-particle emitters and to provide DOE with sufficient information for future planning. The workshop was attended by 36 participants representing radiooncology, nuclear medicine, immunotherapy, radiobiology, molecular biology, biochemistry, radiopharmaceutical chemistry, dosimetry, and physics. This report provides a summary of the key points and recommendations arrived at during the conference.

  15. Experimental investigation of thermal emittance components of copper photocathode

    Directory of Open Access Journals (Sweden)

    H. J. Qian

    2012-04-01

    Full Text Available With progress of photoinjector technology, thermal emittance has become the primary limitation of electron beam brightness. Extensive efforts have been devoted to study thermal emittance, but experiment results differ between research groups and few can be well interpreted. Besides the ambiguity of photoemission mechanism, variations of cathode surface conditions during cathode preparation, such as work function, field enhancement factor, and surface roughness, will cause thermal emittance differences. In this paper, we report an experimental study of electric field dependence of copper cathode quantum efficiency (QE and thermal emittance in a radio frequency (rf gun, through which in situ cathode surface parameters and thermal emittance contributions from photon energy, Schottky effect, and surface roughness are extracted. It is found the QE of a copper cathode illuminated by a 266 nm UV laser increased substantially to 1.5×10^{-4} after cathode cleaning during rf conditioning, and a copper work function of 4.16 eV, which is much lower than nominal value (4.65 eV, was measured. Experimental results also show a thermal emittance growth as much as 0.92  mm mrad/mm at 50  MV/m due to the cathode surface roughness effect, which is consistent with cathode surface morphology measurements.

  16. 22 CFR 213.13 - Interest and charges pending waiver or review.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Interest and charges pending waiver or review. 213.13 Section 213.13 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT CLAIMS COLLECTION Collection § 213.13 Interest and charges pending waiver or review. Interest, penalty charges and...

  17. 72/74As-labeling of HPMA based polymers for long-term in vivo PET imaging

    DEFF Research Database (Denmark)

    Herth, Matthias M; Barz, Matthias; Jahn, Markus

    2010-01-01

    In the context of molecular imaging, various polymers based on the clinically approved N-(2-hydroxypropyl)-methacrylamide (HPMA) have been radio-labeled using longer-living positron emitters 72As t1/2=26 h or 74As t1/2=17.8 d. This approach may lead to non-invasive determination of the long...

  18. Design for a practical, low-emittance damping ring

    International Nuclear Information System (INIS)

    Krejcik, P.

    1988-01-01

    The luminosity requirements for future high-energy linear colliders calls for very low emittances in the two beams. These low emittances can be achieved with damping rings, but, in order to reach the design goal of a factor 10 improvement over present day machines, great care must be taken in their design. This paper emphasizes the need to address simultaneously all of the factors which limit the operational emittance in the ring. Particularly since in standard designs there is a conflict between different design parameters which makes it difficult to extrapolate such designs to very low emittances. The approach chosen here is to resolve such conflicts by separating their design solutions. Wigglers are used predominantly in zero-dispersion regions to achieve the desired damping rate, whereas in the arcs high dispersion insertions are made in regions of zero curvature to allow for easier chromaticity control

  19. 42 CFR 57.213a - Loan cancellation reimbursement.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Loan cancellation reimbursement. 57.213a Section 57... Professions Student Loans § 57.213a Loan cancellation reimbursement. (a) For loans made prior to October 22... credited to this insurance fund), and used only to reimburse the school for the institutional share of any...

  20. 20 CFR 410.213 - Duration of entitlement; child.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Duration of entitlement; child. 410.213...; Filing of Claims and Evidence § 410.213 Duration of entitlement; child. (a) An individual is entitled to benefits as a child for each month beginning with the first month in which all of the conditions of...

  1. Preparation and in vivo evaluation of novel linkers for 211At labeling of proteins

    International Nuclear Information System (INIS)

    Talanov, Vladimir S.; Yordanov, Alexander T.; Garmestani, Kayhan; Milenic, Diane E.; Arora, Hans C.; Plascjak, Paul S.; Eckelman, William C.; Waldmann, Thomas A.; Brechbiel, Martin W.

    2004-01-01

    The syntheses, radiolabeling, antibody conjugation and in vivo evaluation of new linkers for 211 At labeling of monoclonal antibodies are described. Syntheses of the N-succinimidyl esters and labeling with 211 At to form succinimidyl 4-methoxymethyl-3-[ 211 At]astatobenzoate (9) and succinimidyl 4-methylthiomethyl-3-[ 211 At]astatobenzoate (11) from the corresponding bromo-aryl esters is reported. Previously reported succinimidyl N-{4-[ 211 At]astatophenethyl}succinamate (SAPS) is employed as a standard of in vivo stability. Each agent is conjugated with Herceptin in parallel with their respective 125 I analogue, succinimidyl 4-methoxymethyl-3-[ 125 I]iodobenzoate (10), succinimidyl 4-methylthiomethyl-3-[ 125 I]iodobenzoate (12) and succinimidyl N-{4-[ 125 I]iodophenethyl}succinamate (SIPS), respectively, for comparative assessment in LS-174T xenograft-bearing mice. With 9 and 11, inclusion of an electron pair donor in the ortho position does not appear to provide in vivo stability comparable to SAPS. Variables in radiolabeling chemistry of these three agents with 211 At are notable. Sequential elimination of acetic acid and oxidizing agent, N-chlorosuccinimide (NCS), from the 211 At radiolabeling protocol for forming SAPS improves yield, product purity and consistency. NCS appears to be critical for the radiolabeling of 6 with 211 At. Formation of 11, however, is found to require the absence of NCS. Elimination of acetic acid is found to have no effect on radiolabeling efficiency or yield for either of these reactions

  2. Design of a minimum emittance nBA lattice

    Science.gov (United States)

    Lee, S. Y.

    1998-04-01

    An attempt to design a minimum emittance n-bend achromat (nBA) lattice has been made. One distinct feature is that dipoles with two different lengths were used. As a multiple bend achromat, five bend achromat lattices with six superperiod were designed. The obtained emittace is three times larger than the theoretical minimum. Tunes were chosen to avoid third order resonances. In order to correct first and second order chromaticities, eight family sextupoles were placed. The obtained emittance of five bend achromat lattices is almost equal to the minimum emittance of five bend achromat lattice consisting of dipoles with equal length.

  3. Remote detection of single emitters via optical waveguides

    Science.gov (United States)

    Then, Patrick; Razinskas, Gary; Feichtner, Thorsten; Haas, Philippe; Wild, Andreas; Bellini, Nicola; Osellame, Roberto; Cerullo, Giulio; Hecht, Bert

    2014-05-01

    The integration of lab-on-a-chip technologies with single-molecule detection techniques may enable new applications in analytical chemistry, biotechnology, and medicine. We describe a method based on the reciprocity theorem of electromagnetic theory to determine and optimize the detection efficiency of photons emitted by single quantum emitters through truncated dielectric waveguides of arbitrary shape positioned in their proximity. We demonstrate experimentally that detection of single quantum emitters via such waveguides is possible, confirming the predicted behavior of the detection efficiency. Our findings blaze the trail towards efficient lensless single-emitter detection compatible with large-scale optofluidic integration.

  4. Production of Ra225 precursor for Ac225/Bi213 generators. Final CRADA Report

    International Nuclear Information System (INIS)

    Ehst, D.A.

    2009-01-01

    Russian subcontractors shipped two small deliveries of Ra225 to PNNL for evaluation. The activity was close to the requisite amount in the subcontract. The first labeled properly; the second did not. This showed that the Russians could supply Ra225 to the US; however they proved unable to meet future demands for larger amounts of activity. The US DOE attempts to get Ra225 from Russian should be terminated; the Russians, under Rosatom, are not interested in this business.

  5. Demands for 'off-licence' access to trastuzumab (Herceptin): content analysis of UK newspaper articles.

    Science.gov (United States)

    Hind, Daniel; Wailoo, Allan J; Sutcliffe, Paul

    2011-03-01

    Sensationalized reporting styles and a distorted framing of health-care issues in newspapers may trigger inappropriate commissioning decisions. We evaluated UK press coverage of pre-licensing access to trastuzumab (Herceptin) for early breast cancer as a case study. Content analysis of newspaper articles published between April 2005 and May 2006 were coded by two researchers for interest groups represented, claims made and sensationalized reporting. Disagreements in coding were resolved by a third researcher. One thousand and ninety published articles were identified in the study period and a 20% sample (n = 218) was included in the content analysis. Most articles (76%, 95% CI 71-82) included claims about the clinical benefits of trastuzumab, and this was significantly higher than those expressing the uncertainty surrounding such benefits (6%, 95% CI 3-9) or those that discussed the potential harms (5%, 95% CI 2-8). Articles were significantly more likely to feature claims made by a breast cancer survivor or family member than any other interest group (P articles carried some message to the effect that trastuzumab would make the difference between life and death (47%, 95% CI 40-53). Over a quarter (28%, 95% CI 22-34) suggested that trastuzumab is a 'miracle drug' or similar. The benefits of drugs are highlighted, frequently using sensationalist language, without equal consideration of uncertainty or risks. Health-care purchasers should express decisions in opportunity cost terms; journalists should give fairer coverage to such arguments. © 2010 Blackwell Publishing Ltd.

  6. Movement of Irrigation Water in Soil from a Surface Emitter

    Directory of Open Access Journals (Sweden)

    Ibrahim Abbas Dawood

    2016-09-01

    Full Text Available rickle irrigation is one of the most conservative irrigation techniques since it implies supplying water directly on the soil through emitters. Emitters dissipate energy of water at the end of the trickle irrigation system and provide water at emission points. The area wetted by an emitter depends upon the discharge of emitter, soil texture, initial soil water content, and soil permeability. The objectives of this research were to predict water distribution profiles through different soils for different conditions and quantify the distribution profiles in terms of main characteristics of soil and emitter. The wetting patterns were simulated at the end of each hour for a total time of application of 12 hrs, emitter discharges of 0.5, 0.75, 1, 2, 3, 4, and 5 lph, and five initial volumetric soil water contents. Simulation of water flow from a single surface emitter was carried out by using the numerically-based software Hydrus-2D/3D, Version 2.04. Two approaches were used in developing formulas to predict the domains of the wetted pattern. In order to verify the results obtained by implementing the software Hydrus-2D/3D a field experiment was conducted to measure the wetted diameter and compare measured values with simulated ones. The results of the research showed that the developed formulas to express the wetted diameter and depth in terms of emitter discharge, time of application, and initial soil water content are very general and can be used with very good accuracy.

  7. 25 CFR 213.19 - Crediting advance annual payments.

    Science.gov (United States)

    2010-04-01

    ... been made. No refund of such advance payments made under any lease will be allowed in the event the royalty on production is not sufficient to equal such advance payment; nor will any part of the moneys so... 25 Indians 1 2010-04-01 2010-04-01 false Crediting advance annual payments. 213.19 Section 213.19...

  8. Jamming of Quantum Emitters by Active Coated Nanoparticles

    DEFF Research Database (Denmark)

    Arslanagic, Samel; Ziolkowski, Richard W.

    2013-01-01

    to effectively cloak the emitters to a far-field observer is reported and explained through thorough near- and far-field investigations. This property offers an interesting route toward the jamming of quantum emitters/nanoantennas that might be of potential use, for instance, in biological fluorescence assays...

  9. Biosynthetic incorporation of [75Se]selenomethionine: a new method for labelling lymphocyte membrane antigens

    International Nuclear Information System (INIS)

    Dosseto, M.; Rohner, C.; Pierres, M.; Goridis, C.

    1981-01-01

    A novel approach for radiolabelling lymphocyte membrane antigens is described. This technique is based on the use of the γ-emitting amino acid analogue [ 75 Se]selenomethionine. Human HLA-A, B, C and DR heavy and light chains and mouse Ia antigens were efficiently labelled by this technique and were precipitated with monoclonal antibodies. Approximately the same radioactivity was incorporated into the HLA-A, B, C chains whether [ 75 Se]selenomethionine, [ 35 S]methionine or [ 3 H]leucine were used as precursors. Easily detectable as a γ-emitter, [ 75 Se]selenomethionine thus constitutes a useful biosynthetic label of lymphocyte surface antigens. The same method was used to label immunoglobulins produced by hybridomas and to determine the nature of the secreted light chains. (Auth.)

  10. Transverse Emittance Measurement and Preservation at the LHC

    CERN Document Server

    AUTHOR|(CDS)2082907

    The Large Hadron Collider (LHC) at CERN is a high energy storage ring that provides proton and heavy ion collisions to study fundamental particle physics. The luminosity production is closely linked to emittance preservation in the accelerator. The transverse emittance is the phase space density of the beam and should be conserved when the particle beam is transformed through the accelerator. Perturbing effects, however, can lead to emittance increase and hence luminosity degradation. Measuring the emittance growth is a complex task with high intensity beams and changing energies. The machine optics and the transverse beam size have to be measured as accurately as possible. Beta function measurements with k-modulation will be discussed. With this method the quadrupole focussing strength is varied and the resulting tune change is traced to determine the beta function at the quadrupole. A new k-modulation measurement tool was developed for the LHC. The fully automatic and online measurement system takes constra...

  11. Emittance increase caused by core depletion in collisions

    CERN Document Server

    Bruce, R

    2009-01-01

    A new effect is presented, which changes the emittance during colliding-beam operation in circular colliders. If the initial transverse distribution is Gaussian, the collision probability is much higher for particles in the core of the beam than in the tails. When small-amplitude particles are removed, the remaining ones therefore have a larger transverse emittance. This effect, called core depletion, may cause a decrease in luminosity. An approximate analytic model is developed to study the effect and benchmarked against a multiparticle tracking simulation. Finally, the time evolution of the intensity and emittances of a Pb bunch in the Large Hadron Collider (LHC) at CERN is calculated, taking into account also other processes than collisions. The results show that integrated luminosity drops by 3--4% if core depletion is taken into account. It is also found that core depletion causes the transverse emittance to be larger when more experiments are active. This observation could be checked against experimenta...

  12. Selective solar absorber emittance measurement at elevated temperature

    Science.gov (United States)

    Giraud, Philémon; Braillon, Julien; Raccurt, Olivier

    2017-06-01

    Durability of solar components for CSP (Concentrated Solar Power Plant) technologies is a key point to lower cost and ensure their large deployment. These technologies concentrated the solar radiation by means of mirrors on a receiver tube where it is collected as thermal energy. The absorbers are submitted to strong environmental constraints and the degradation of their optical properties (emittance and solar absorbance) have a direct impact on performance. The characterization of a material in such condition is complicated and requires advanced apparatuses, and different measurement methods exist for the determination of the two quantities of relevance regarding an absorber, which are its emittance and its solar absorbance. The objective is to develop new optical equipment for measure the emittance of this solar absorber at elevated temperature. In this paper, we present an optical bench developed for emittance measurement on absorbers is conditions of use. Results will be shown, with a discussion of some factors of influence over this measurement and how to control them.

  13. Strong coupling of collection of emitters on hyperbolic meta-material

    Science.gov (United States)

    Biehs, Svend-Age; Xu, Chenran; Agarwal, Girish S.

    2018-04-01

    Recently, considerable effort has been devoted to the realization of a strong coupling regime of the radiation matter interaction in the context of an emitter at a meta surface. The strong interaction is well realized in cavity quantum electrodynamics, which also show that strong coupling is much easier to realize using a collection of emitters. Keeping this in mind, we study if emitters on a hyperbolic meta materials can yield a strong coupling regime. We show that strong coupling can be realized for densities of emitters exceeding a critical value. A way to detect strong coupling between emitters and hyperbolic metamaterials is to use the Kretschman-Raether configuration. The strong coupling appears as the splitting of the reflectivity dip. In the weak coupling regime, the dip position shifts. The shift and splitting can be used to sense active molecules at surfaces.

  14. 19 CFR 213.3 - Determination of small business eligibility.

    Science.gov (United States)

    2010-04-01

    ... Section 213.3 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION INVESTIGATIONS OF UNFAIR PRACTICES IN IMPORT TRADE TRADE REMEDY ASSISTANCE § 213.3 Determination of small business eligibility. (a... technical assistance from joint applicants, trade associations and unions. If several businesses jointly or...

  15. High-efficency stable 213-nm generation for LASIK application

    Science.gov (United States)

    Wang, Zhenglin; Alameh, Kamal; Zheng, Rong

    2005-01-01

    213nm Solid-state laser technology provides an alternative method to replace toxic excimer laser in LASIK system. In this paper, we report a compact fifth harmonic generation system to generate high pulse energy 213nm laser from Q-switched Nd:YAG laser for LASIK application based on three stages harmonic generation procedures. A novel crystal housing was specifically designed to hold the three crystals with each crystal has independent, precise angular adjustment structure and automatic tuning control. The crystal temperature is well maintained at ~130°C to improve harmonic generation stability and crystal operation lifetime. An output pulse energy 35mJ is obtained at 213nm, corresponding to total conversion efficiency ~10% from 1064nm pump laser. In system verification tests, the 213nm output power drops less than 5% after 5 millions pulse shots and no significant damage appears in the crystals.

  16. Radial arrays of nano-electrospray ionization emitters and methods of forming electrosprays

    Science.gov (United States)

    Kelly, Ryan T [West Richland, WA; Tang, Keqi [Richland, WA; Smith, Richard D [Richland, WA

    2010-10-19

    Electrospray ionization emitter arrays, as well as methods for forming electrosprays, are described. The arrays are characterized by a radial configuration of three or more nano-electrospray ionization emitters without an extractor electrode. The methods are characterized by distributing fluid flow of the liquid sample among three or more nano-electrospray ionization emitters, forming an electrospray at outlets of the emitters without utilizing an extractor electrode, and directing the electrosprays into an entrance to a mass spectrometry device. Each of the nano-electrospray ionization emitters can have a discrete channel for fluid flow. The nano-electrospray ionization emitters are circularly arranged such that each is shielded substantially equally from an electrospray-inducing electric field.

  17. The cataphoretic emitter effect exhibited in high intensity discharge lamp electrodes

    Science.gov (United States)

    Mentel, Juergen

    2018-01-01

    A mono-layer of atoms, electropositive with respect to the substrate atoms, forms a dipole layer, reducing its work function. Such a layer is generated by diffusion of emitter material from the interior of the substrate, by vapour deposition or by deposition of emitter material onto arc electrodes by cataphoresis. This cataphoretic emitter effect is investigated within metal halide lamps with transparent YAG ceramic burners, and within model lamps. Within the YAG lamps, arcs are operated with switched-dc current between rod shaped tungsten electrodes in high pressure Hg vapour seeded with metal iodides. Within the model lamps, dc arcs are operated between rod-shaped tungsten electrodes—one doped—in atmospheric pressure Ar. Electrode temperatures are determined by 1λ -pyrometry, combined with simulation of the electrode heat balance. Plasma temperatures, atom and ion densities of emitter material are determined by emission and absorption spectroscopy. Phase resolved measurements in YAG lamps seeded with CeI3, CsI, DyI3, TmI3 and LaI3 show, within the cathodic half period, a reduction of the electrode temperature and an enhanced metal ion density in front of the electrode, and an opposite behavior after phase reversal. With increasing operating frequency, the state of the cathode overlaps onto the anodic phase—except for Cs, being low in adsorption energy. Generally, the phase averaged electrode tip temperature is reduced by seeding a lamp with emitter material; its height depends on admixtures. Measurements at tungsten electrodes doped with ThO2, La2O3 and Ce2O3 within the model lamp show that evaporated emitter material is redeposited by an emitter ion current onto the electrode surface. It reduces the work function of tungsten cathodes above the evaporation temperature of the emitter material, too; and also of cold anodes, indicating a field reversal in front of them. The formation of an emitter spot at low cathode temperature and high emitter material

  18. Low emittance lattices for electron storage rings revisited

    International Nuclear Information System (INIS)

    Trbojevic, D.; Courant, E.

    1994-01-01

    Conditions for the lowest possible emittance of the lattice for electron storage rings are obtained by a simplified analytical approach. Examples of electron storage lattices with minimum emittances are presented. A simple graphical presentation in the normalized dispersion space (Floquet's transformation) is used to illustrate the conditions and results

  19. BEAM EMITTANCE MEASUREMENT TOOL FOR CEBAF OPERATIONS

    International Nuclear Information System (INIS)

    Chevtsov, Pavel; Tiefenback, Michael

    2008-01-01

    A new software tool was created at Jefferson Lab to measure the emittance of the CEBAF electron beams. The tool consists of device control and data analysis applications. The device control application handles the work of wire scanners and writes their measurement results as well as the information about accelerator settings during these measurements into wire scanner data files. The data analysis application reads these files and calculates the beam emittance on the basis of a wire scanner data processing model. Both applications are computer platform independent but are mostly used on LINUX PCs recently installed in the accelerator control room. The new tool significantly simplifies beam emittance measurement procedures for accelerator operations and contributes to a very high availability of the CEBAF machine for the nuclear physics program at Jefferson Lab.

  20. Achievement of ultralow emittance coupling in the Australian Synchrotron storage ring

    Directory of Open Access Journals (Sweden)

    R. Dowd

    2011-01-01

    Full Text Available Investigations into producing an electron beam with ultralow vertical emittance have been conducted using the Australian Synchrotron 3 GeV storage ring. A method of tuning the emittance coupling (ϵ_{y}/ϵ_{x} has been developed using a machine model calibrated through the linear optics from closed orbits method. Direct measurements of the beam emittance have not been possible due to diagnostic limitations, however two independent indirect measurements both indicate a vertical emittance of 1.2–1.3 pm rad (ϵ_{y}/ϵ_{x}=0.01%. Other indirect measurements support the validity of these results. This result is the smallest vertical emittance currently achieved in a storage ring.

  1. Measurements of Transverse Emittance for RF Photocathode Gun at the PAL

    CERN Document Server

    Park Jang Ho; Park, Sung-Ju; Soo Ko In; Wang, Xijie; Woon Parc, Yong; Xiang, Dao

    2005-01-01

    A BNL GUN-IV type RF photo-cathode gun is under fabrication for use in the FIR (Far Infra-Red) facility being built at the Pohang Accelerator Laboratory (PAL). Performance test of the gun will include the measurement of transverse emittance profile along the longitudinal direction. Successful measurement of the emittance profile will provide powerful tool for the commissioning of the 4GLS (4th generation light source) injectors based on the emittance compensation principle. We are going to achieve this withthe use of pepper-pot based emittance meters that can be moved along the longitudinal direction. In this article, we present design considerations on the emittance meter with the resolution of 1 mm mrad.

  2. Bi-Force

    DEFF Research Database (Denmark)

    Sun, Peng; Speicher, Nora K; Röttger, Richard

    2014-01-01

    of pairwise similarities. We first evaluated the power of Bi-Force to solve dedicated bicluster editing problems by comparing Bi-Force with two existing algorithms in the BiCluE software package. We then followed a biclustering evaluation protocol in a recent review paper from Eren et al. (2013) (A...... comparative analysis of biclustering algorithms for gene expressiondata. Brief. Bioinform., 14:279-292.) and compared Bi-Force against eight existing tools: FABIA, QUBIC, Cheng and Church, Plaid, BiMax, Spectral, xMOTIFs and ISA. To this end, a suite of synthetic datasets as well as nine large gene expression...

  3. Alpha Particles Induce Autophagy in Multiple Myeloma Cells.

    Science.gov (United States)

    Gorin, Jean-Baptiste; Gouard, Sébastien; Ménager, Jérémie; Morgenstern, Alfred; Bruchertseifer, Frank; Faivre-Chauvet, Alain; Guilloux, Yannick; Chérel, Michel; Davodeau, François; Gaschet, Joëlle

    2015-01-01

    Radiation emitted by the radionuclides in radioimmunotherapy (RIT) approaches induce direct killing of the targeted cells as well as indirect killing through the bystander effect. Our research group is dedicated to the development of α-RIT, i.e., RIT using α-particles especially for the treatment of multiple myeloma (MM). γ-irradiation and β-irradiation have been shown to trigger apoptosis in tumor cells. Cell death mode induced by (213)Bi α-irradiation appears more controversial. We therefore decided to investigate the effects of (213)Bi on MM cell radiobiology, notably cell death mechanisms as well as tumor cell immunogenicity after irradiation. Murine 5T33 and human LP-1 MM cell lines were used to study the effects of such α-particles. We first examined the effects of (213)Bi on proliferation rate, double-strand DNA breaks, cell cycle, and cell death. Then, we investigated autophagy after (213)Bi irradiation. Finally, a coculture of dendritic cells (DCs) with irradiated tumor cells or their culture media was performed to test whether it would induce DC activation. We showed that (213)Bi induces DNA double-strand breaks, cell cycle arrest, and autophagy in both cell lines, but we detected only slight levels of early apoptosis within the 120 h following irradiation in 5T33 and LP-1. Inhibition of autophagy prevented (213)Bi-induced inhibition of proliferation in LP-1 suggesting that this mechanism is involved in cell death after irradiation. We then assessed the immunogenicity of irradiated cells and found that irradiated LP-1 can activate DC through the secretion of soluble factor(s); however, no increase in membrane or extracellular expression of danger-associated molecular patterns was observed after irradiation. This study demonstrates that (213)Bi induces mainly necrosis in MM cells, low levels of apoptosis, and autophagy that might be involved in tumor cell death.

  4. Aluminum oxide film thickness and emittance

    International Nuclear Information System (INIS)

    Thomas, J.K.; Ondrejcin, R.S.

    1991-11-01

    Aluminum reactor components which are not actively cooled could be subjected to high temperatures due to gamma heating after the core coolant level dropped during the ECS phase of a hypothetical LOCA event. Radiative heat transfer is the dominant heat transfer process in this scenario and therefore the emittance of these components is of interest. Of particular interest are the safety rod thimbles and Mark 60B blanket assemblies; for the K Reactor, these components have been exposed to low temperature (< 55 degrees C) moderator for about a year. The average moderator temperature was assumed to be 30 degrees C. The Al oxide film thickness at this temperature, after one year of exposure, is predicted to be 6.4 μm ± 10%; insensitive to exposure time. Dehydration of the film during the gamma heating accident would result in a film thickness of 6.0 μm ± 11%. Total hemispherical emittance is predicted to be 0.69 at 96 degrees C, decreasing to 0.45 at 600 degrees C. Some phenomena which would tend to yield thicker oxide films in the reactor environment relative to those obtained under experimental conditions were neglected and the predicted film thickness values are therefore conservative. The emittance values predicted for a given film thickness are also conservative. The conservativisms inherent in the predicted emittance are particularly relevant for uncertainty analysis of temperatures generated using these values

  5. Measured emittance dependence on injection method in laser plasma accelerators

    Science.gov (United States)

    Barber, Samuel; van Tilborg, Jeroen; Schroeder, Carl; Lehe, Remi; Tsai, Hai-En; Swanson, Kelly; Steinke, Sven; Nakamura, Kei; Geddes, Cameron; Benedetti, Carlo; Esarey, Eric; Leemans, Wim

    2017-10-01

    The success of many laser plasma accelerator (LPA) based applications relies on the ability to produce electron beams with excellent 6D brightness, where brightness is defined as the ratio of charge to the product of the three normalized emittances. As such, parametric studies of the emittance of LPA generated electron beams are essential. Profiting from a stable and tunable LPA setup, combined with a carefully designed single-shot transverse emittance diagnostic, we present a direct comparison of charge dependent emittance measurements of electron beams generated by two different injection mechanisms: ionization injection and shock induced density down-ramp injection. Notably, the measurements reveal that ionization injection results in significantly higher emittance. With the down-ramp injection configuration, emittances less than 1 micron at spectral charge densities up to 2 pC/MeV were measured. This work was supported by the U.S. DOE under Contract No. DE-AC02-05CH11231, by the NSF under Grant No. PHY-1415596, by the U.S. DOE NNSA, DNN R&D (NA22), and by the Gordon and Betty Moore Foundation under Grant ID GBMF4898.

  6. Transverse-to-longitudinal Emittance-exchange with an Energy Chirped Beam

    Energy Technology Data Exchange (ETDEWEB)

    Thangaraj, J.; Ruan, J.; Johnson, A.S.; Thurman-Keup, R.; Lumpkin, A.H.; Santucci, J.; Sun, Y.-E; Maxwell, T.; Edwards, H.; /Fermilab

    2012-05-01

    Emittance exchange has been proposed to increase the performance of free electron lasers by tailoring the phase space of an electron beam. The principle of emittance exchange - where the transverse phase space of the electron beam is exchanged with the longitudinal phase space - has been demonstrated recently at the A0 photoinjector. The experiment used a low charge bunch (250 pC) with no energy chirp. Theory predicts an improvement in the emittance exchange scheme when the incoming beam has an energy chirp imparted on it. The energy chirp helps to overcome the thick lens effect of the deflecting mode cavity and other second order effects that might lead to an incomplete emittance exchange at higher charges. In this work, we report experimental and simulation results from operating the emittance exchange beam line using an energy chirped beam with higher charge (500 pC) at different RF-chirp settings.

  7. Internal Auger emitters: effects on spermatogenesis and oogenesis in mice

    International Nuclear Information System (INIS)

    Rao, D.V.; Mylavarapu, V.B.; Sastry, K.S.R.; Howell, R.W.

    1988-01-01

    The in vivo biological effects of Auger emitters are investigated using [A] spermatogenesis in mouse testis, and [B] oogenesis in mouse ovary as experimental models. Spermhead survival and induction of abnormal sperm, following intratesticular administration of radiopharmaceuticals, were the end points in Model A. Of interest in Model B is primary oocyte survival after intraperitoneal injection of the radiochemicals. The effectiveness of the Auger emitter is determined relative to its beta emitting companion or external X-rays in the absence of such an analogue. Results reveal pronounced effects of Auger emitters on all end points, not dependent on mode of administration. The efficacy of the Auger emitter is related intimately to its subcellular distribution, which, is governed by the chemical form of the carrier molecule. Conventional dosimetry is inadequate and biophysically meaningful dosimetric approaches are needed to understand in vivo effects of Auger emitters. (author)

  8. Transverse beam emittance optimization for the injection into BESSY II

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, Felix [Helmholtz Zentrum Berlin, Institut Beschleunigerphysik (Germany); Humboldt-Universitaet zu Berlin, Institut fuer Physik (Germany)

    2016-07-01

    For top up injection into the storage ring BESSY II an average injection efficiency of at least 90% is required. In low alpha mode the injection efficiency does not meet the requirements. Future BESSY II features will include shorter bunches in the storage ring (VSR) and user transparent injection with a non linear kicker. These will raise the demands on the quality of the injected beam even further. This work investigates the development of transverse emittance over the acceleration cycle in the synchrotron and the possibility of transverse emittance exchange by a sequence of skew quadrupoles in the transfer line. Results of emittance measurements and emittance exchange simulations will be given.

  9. Asymmetric synthesis including enzymatic catalysis of 11C and 13N labelled amino acids

    International Nuclear Information System (INIS)

    Langstrom, B.; Antonio, G.; Bjurling, P.; Fasth, K.J.; Westerberg, G.; Watanabe, Y.

    1993-01-01

    Use of asymmetric synthesis in production of 11 C- and 13 N-labelled amino acids has been shown to be a useful approach in order to prepare amino acids routinely for PET-studies. Such PET-studies are focused either on problems related to amino acid transport, protein synthesis rate or the turnover of neurotransmitters from amino acids. The paper discusses matters regarding synthetic strategies and techniques involving production of precursors, labelled intermediates and main reaction sequences. In synthesis using the short-lived β + -emitters like 11 C and 13 N with T 1/2 of 20.3 and 10.0 min respectively, many special aspects have to be considered. The use of enzymes as catalysts has shown to be a useful tool in such preparations. The design of the labelled amino acids especially considering the stereochemistry, the position of the label will be addressed since these points are important both with regard to the application of the labelled amino acids as well as to the synthesis itself. In this presentation of the synthesis of labelled amino acids these various aspects are discussed

  10. Antimicrobial activity and mechanism of PDC213, an endogenous peptide from human milk

    International Nuclear Information System (INIS)

    Sun, Yazhou; Zhou, Yahui; Liu, Xiao; Zhang, Fan; Yan, Linping; Chen, Ling; Wang, Xing; Ruan, Hongjie; Ji, Chenbo; Cui, Xianwei; Wang, Jiaqin

    2017-01-01

    Human milk has always been considered an ideal source of elemental nutrients to both preterm and full term infants in order to optimally develop the infant's tissues and organs. Recently, hundreds of endogenous milk peptides were identified in human milk. These peptides exhibited angiotensin-converting enzyme inhibition, immunomodulation, or antimicrobial activity. Here, we report the antimicrobial activity and mechanism of a novel type of human antimicrobial peptide (AMP), termed PDC213 (peptide derived from β-Casein 213-226 aa). PDC213 is an endogenous peptide and is present at higher levels in preterm milk than in full term milk. The inhibitory concentration curve and disk diffusion tests showed that PDC213 had obvious antimicrobial against S. aureus and Y. enterocolitica, the common nosocomial pathogens in neonatal intensive care units (NICUs). Fluorescent dye methods, electron microscopy experiments and DNA-binding activity assays further indicated that PDC213 can permeabilize bacterial membranes and cell walls rather than bind intracellular DNA to kill bacteria. Together, our results suggest that PDC213 is a novel type of AMP that warrants further investigation. - Highlights: • PDC213 is an endogenous peptide presenting higher levels in preterm milk. • PDC213 showed obvious antimicrobial against S. aereus and Y. enterocolitica. • PDC213 can permeabilize bacterial membranes and cell walls to kill bacterias. • PDC213 is a novel type of antimicrobial peptides worthy further investigation.

  11. 49 CFR 1544.213 - Use of explosives detection systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 9 2010-10-01 2010-10-01 false Use of explosives detection systems. 1544.213...: AIR CARRIERS AND COMMERCIAL OPERATORS Operations § 1544.213 Use of explosives detection systems. (a... explosives detection system approved by TSA to screen checked baggage on international flights. (b) Signs and...

  12. A numerical study of emittance growths in RF guns

    CERN Document Server

    Masuda, K; Sobajima, M; Kitagaki, J; Ohnishi, M; Toku, H; Yoshikawa, K

    1999-01-01

    A beam with greatly reduced emittance is required for further improvements of FELs, in particular, for FELs of shorter wavelengths, and of narrower bandwidths. From this viewpoint, the BNL/SLAC/UCLA 1.6-cell S-band photocathode RF gun performance characteristics were calculated, first in order to evaluate what may contribute to the emittance growths in photocathode RF guns. We developed an RF gun to produce an electron beam with an extremely low emittance, by using a 2-D simulation code. It is found that, by optimizing the laser injection phase, the drive laser spot radius and the cavity shape around the laser spot, the beam emittance by the 1.6-cell RF gun can be greatly reduced to 2.1 pi mm mrad, from the previous 4.4 pi mm mrad of the original shape.

  13. Simulation studies of emittance growth in RMS mismatched beams

    International Nuclear Information System (INIS)

    Cucchetti, A.; Wangler, T.; Reiser, M.

    1991-01-01

    As shown in a separate paper, a charged-particle beam, whose rms size is not matched when injected into a transport channel or accelerator, has excess energy compared with that of a matched beam. If nonlinear space-charge forces are present and the mismatched beam transforms to a matched equilibrium state, rms-emittance growth will occur. The theory yields formulas for the possible rms-emittance growth, but not for the time it takes to achieve this growth. In this paper we present the results of systematic simulation studies for a mismatched 2-D round beam in an ideal transport channel with continuous linear focusing. Emittance growth rates obtained from the simulations for different amounts of mismatch and initial charge will be presented and the emittance growth will be compared with the theory. 6 refs., 7 figs

  14. Low Emittance Tuning Studies for SuperB

    Energy Technology Data Exchange (ETDEWEB)

    Liuzzo, Simone; /INFN, Pisa; Biagini, Maria; /INFN, Rome; Raimondi, Pantaleo; /INFN, Rome; Donald, Martin; /SLAC

    2012-07-06

    SuperB[1] is an international project for an asymmetric 2 rings collider at the B mesons cm energy to be built in the Rome area in Italy. The two rings will have very small beam sizes at the Interaction Point and very small emittances, similar to the Linear Collider Damping Rings ones. In particular, the ultra low vertical emittances, 7 pm in the LER and 4 pm in the HER, need a careful study of the misalignment errors effects on the machine performances. Studies on the closed orbit, vertical dispersion and coupling corrections have been carried out in order to specify the maximum allowed errors and to provide a procedure for emittance tuning. A new tool which combines MADX and Matlab routines has been developed, allowing for both corrections and tuning. Results of these studies are presented.

  15. Arc-textured metal surfaces for high thermal emittance space radiators

    International Nuclear Information System (INIS)

    Banks, B.A.; Rutledge, S.K.; Mirtich, M.J.; Behrend, T.; Hotes, D.; Kussmaul, M.; Barry, J.; Stidham, C.; Stueber, T.; DiFilippo, F.

    1994-01-01

    Carbon arc electrical discharges struck across the surfaces of metals such as Nb-1% Zr, alter the morphology to produce a high thermal emittance surface. Metal from the surface and carbon from the arc electrode vaporize during arcing, and then condense on the metal surface to produce a microscopically rough surface having a high thermal emittance. Quantitative spectral reflectance measurements from 0.33 to 15 μm were made on metal surfaces which were carbon arc treated in an inert gas environment. The resulting spectral reflectance data were then used to calculate thermal emittance as a function of temperature for various methods of arc treatment. The results of arc treatment on various metals are presented for both ac and dc arcs. Surface characterization data, including thermal emittance as a function of temperature, scanning electron microscopy, and atomic oxygen durability, are also presented. Ac arc texturing was found to increase the thermal emittance at 800 K from 0.05. to 0.70

  16. Impact of water temperature and structural parameters on the hydraulic labyrinth-channel emitter performance

    Directory of Open Access Journals (Sweden)

    Ahmed I. Al-Amoud

    2014-06-01

    Full Text Available The effects of water temperature and structural parameters of a labyrinth emitter on drip irrigation hydraulic performance were investigated. The inside structural parameters of the trapezoidal labyrinth emitter include path width (W and length (L, trapezoidal unit numbers (N, height (H, and spacing (S. Laboratory experiments were conducted using five different types of labyrinth-channel emitters (three non-pressure compensating and two pressure-compensating emitters commonly used for subsurface drip irrigation systems. The water temperature effect on the hydraulic characteristics at various operating pressures was recorded and a comparison was made to identify the most effective structural parameter on emitter performance. The pressure compensating emitter flow exponent (x average was 0.014, while non-pressure compensating emitter’s values average was 0.456, indicating that the sensitivity of non-pressure compensating emitters to pressure variation is an obvious characteristic (p<0.001 of this type of emitters. The effects of water temperature on emitter flow rate were insignificant (p>0.05 at various operating pressures, where the flow rate index values for emitters were around one. The effects of water temperature on manufacturer’s coefficient of variation (CV values for all emitters were insignificant (p>0.05. The CV values of the non-pressure compensating emitters were lower than those of pressure compensating emitters. This is typical for most compensating models because they are manufactured with more elements than non-compensating emitters are. The results of regression analysis indicate that N and H are the essential factors (p<0.001 to affect the hydraulic performance.

  17. Bi-induced band gap reduction in epitaxial InSbBi alloys

    Energy Technology Data Exchange (ETDEWEB)

    Rajpalke, M. K.; Linhart, W. M.; Birkett, M.; Alaria, J.; Veal, T. D., E-mail: T.Veal@liverpool.ac.uk [Stephenson Institute for Renewable Energy and Department of Physics, School of Physical Sciences, University of Liverpool, Liverpool L69 7ZF (United Kingdom); Yu, K. M. [Materials Sciences Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, California 94720 (United States); Bomphrey, J. J.; Jones, T. S.; Ashwin, M. J., E-mail: M.J.Ashwin@warwick.ac.uk [Department of Chemistry, University of Warwick, Coventry CV4 7AL (United Kingdom); Sallis, S.; Piper, L. F. J. [Materials Science and Engineering, Binghamton University, Binghamton, New York 13902 (United States)

    2014-11-24

    The properties of molecular beam epitaxy-grown InSb{sub 1−x}Bi{sub x} alloys are investigated. Rutherford backscattering spectrometry shows that the Bi content increases from 0.6% for growth at 350 °C to 2.4% at 200 °C. X-ray diffraction indicates Bi-induced lattice dilation and suggests a zinc-blende InBi lattice parameter of 6.626 Å. Scanning electron microscopy reveals surface InSbBi nanostructures on the InSbBi films for the lowest growth temperatures, Bi droplets at intermediate temperatures, and smooth surfaces for the highest temperature. The room temperature optical absorption edge was found to change from 172 meV (7.2 μm) for InSb to ∼88 meV (14.1 μm) for InSb{sub 0.976}Bi{sub 0.024}, a reduction of ∼35 meV/%Bi.

  18. Study of alternative routes for the production of innovative radionuclides for medical applications

    International Nuclear Information System (INIS)

    Duchemin, Charlotte

    2015-01-01

    Nuclear medicine is a specialty that uses radioactive nuclei for therapy or diagnosis of diseases such as different types of cancer. These radionuclides are coupled to carrier molecules to target sick cells. Currently, only few isotopes are used in clinical practice. However, many others may be of medical interest due to their emitted radiation and/or their half-life that can be adapted to the carrier molecule transit time and to the pathology. The aim of this PhD thesis is to study the production of innovative radionuclides for therapy and diagnosis applications in collaboration with the GIP ARRONAX, which possesses a multi-particle high energy cyclotron. A fundamental physical parameter to access the production rate of a radionuclide is the production cross section. Experimental data were measured for a selection of radionuclides: photon emitter (Tc-99m) and positron emitter (Sc-44g) for diagnosis, as well as electron emitters (Re-186, Tb-155 and Sn-117m) and α particles emitters (Th-226, Ra-223 and Bi-213) for therapeutic applications. These acquired data are obtained using alternative production routes compared to the commonly used. Data related to the contaminants produced during the irradiations were also extracted. The experimental cross section values are compared with theoretical model predictions. The large set of data obtained contributes to the theoretical physicist studies allowing to constrain their models to improve and/or validate them. (author)

  19. On the design guideline for the low emittance synchrotron radiation source

    International Nuclear Information System (INIS)

    Kamiya, Y.; Kihara, M.

    1983-09-01

    In this note we will describe how the emittance of the electron storage ring is determined by the orbit parameters of the storage ring and show the lowest value of emittance which is achieved theoretically. Implication of this note with regard to the design of the low emittance storage ring will be discussed. (author)

  20. Homogeneous Gaussian Profile P+-Type Emitters: Updated Parameters and Metal-Grid Optimization

    Directory of Open Access Journals (Sweden)

    M. Cid

    2002-10-01

    Full Text Available P+-type emitters were optimized keeping the base parameters constant. Updated internal parameters were considered. The surface recombination velocity was considered variable with the surface doping level. Passivated homogeneous emitters were found to have low emitter recombination density and high collection efficiency. A complete structure p+nn+ was analyzed, taking into account optimized shadowing and metal-contacted factors for laboratory cells as function of the surface doping level and the emitter thickness. The base parameters were kept constant to make the emitter characteristics evident. The most efficient P+-type passivated homogeneous emitters, provide efficiencies around 21% for a wide range of emitter sheet resistivity (50 -- 500 omega/ with the surface doping levels Ns=1×10(19 cm-3 and 5×10(19 cm-3. The output electrical parameters were evaluated considering the recently proposed value n i=9.65×10(9 (cm-3. A non-significant increase of 0.1% in the efficiency was obtained, validating all the conclusions obtained in this work, considering n i=1×10(10 cm-3.

  1. Minimum emittance of three-bend achromats

    International Nuclear Information System (INIS)

    Li Xiaoyu; Xu Gang

    2012-01-01

    The calculation of the minimum emittance of three-bend achromats (TBAs) made by Mathematical software can ignore the actual magnets lattice in the matching condition of dispersion function in phase space. The minimum scaling factors of two kinds of widely used TBA lattices are obtained. Then the relationship between the lengths and the radii of the three dipoles in TBA is obtained and so is the minimum scaling factor, when the TBA lattice achieves its minimum emittance. The procedure of analysis and the results can be widely used in achromats lattices, because the calculation is not restricted by the actual lattice. (authors)

  2. Dispersion interactions between neighboring Bi atoms in (BiH3 )2 and Te(BiR2 )2.

    Science.gov (United States)

    Haack, Rebekka; Schulz, Stephan; Jansen, Georg

    2018-03-13

    Triggered by the observation of a short Bi⋯Bi distance and a BiTeBi bond angle of only 86.6° in the crystal structure of bis(diethylbismuthanyl)tellurane quantum chemical computations on interactions between neighboring Bi atoms in Te(BiR 2 ) 2 molecules (R = H, Me, Et) and in (BiH 3 ) 2 were undertaken. Bi⋯Bi distances atoms were found to significantly shorten upon inclusion of the d shells of the heavy metal atoms into the electron correlation treatment, and it was confirmed that interaction energies from spin component-scaled second-order Møller-Plesset theory (SCS-MP2) agree well with coupled-cluster singles and doubles theory including perturbative triples (CCSD(T)). Density functional theory-based symmetry-adapted perturbation theory (DFT-SAPT) was used to study the anisotropy of the interplay of dispersion attraction and steric repulsion between the Bi atoms. Finally, geometries and relative stabilities of syn-syn and syn-anti conformers of Te(BiR 2 ) 2 (R = H, Me, Et) and interconversion barriers between them were computed. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  3. Are radiogallium-labelled DOTA-conjugated somatostatin analogues superior to those labelled with other radiometals?

    Energy Technology Data Exchange (ETDEWEB)

    Antunes, P.; Ginj, M.; Zhang, H.; Maecke, H. [University Hospital Basel, Division of Radiological Chemistry, Basel (Switzerland); Waser, B.; Reubi, J.C. [University of Bern, Institute of Pathology, Bern (Switzerland); Baum, R.P. [Zentralklinik Bad Berka, Department of Nuclear Medicine/PETCT-Center, Bad Berka (Germany)

    2007-07-15

    Gallium-68 is a metallic positron emitter with a half-life of 68 min that is ideal for the in vivo use of small molecules, such as [{sup 68}Ga-DOTA,Tyr{sup 3}]octreotide, in the diagnostic imaging of somatostatin receptor-positive tumours. In preclinical studies it has shown a striking superiority over its {sup 111}In-labelled congener. The purpose of this study was to evaluate whether third-generation somatostatin-based, radiogallium-labelled peptides show the same superiority. Peptides were synthesised on solid phase. The receptor affinity was determined by in vitro receptor autoradiography. The internalisation rate was studied in AR4-2J and hsst-HEK-transfected cell lines. The pharmacokinetics was studied in a rat xenograft tumour model, AR4-2J. All peptides showed high affinities on hsst2, with the highest affinity for the Ga{sup III}-complexed peptides. On hsst3 the situation was reversed, with a trend towards lower affinity of the Ga{sup III} peptides. A significantly increased internalisation rate was found in sst2-expressing cells for all {sup 67}Ga-labelled peptides. Internalisation into HEK-sst3 was usually faster for the {sup 111}In-labelled peptides. No internalisation was found into sst5. Biodistribution studies employing [{sup 67}Ga-DOTA,1-Nal{sup 3}]octreotide in comparison to [{sup 111}In-DOTA,1-Nal{sup 3}]octreotide and [{sup 67}Ga-DOTA,Tyr{sup 3}]octreotide showed a significantly higher and receptor-mediated uptake of the two{sup 67}Ga-labelled peptides in the tumour and somatostatin receptor-positive tissues. A patient study illustrated the potential advantage of a broad receptor subtype profile radiopeptide over a high-affinity sst2-selective radiopeptide. This study demonstrates that {sup 67/68}Ga-DOTA-octapeptides show distinctly better preclinical, pharmacological performances than the {sup 111}In-labelled peptides, especially on sst2-expressing cells and the corresponding animal models. They may be excellent candidates for further

  4. Are radiogallium-labelled DOTA-conjugated somatostatin analogues superior to those labelled with other radiometals?

    International Nuclear Information System (INIS)

    Antunes, P.; Ginj, M.; Zhang, H.; Maecke, H.; Waser, B.; Reubi, J.C.; Baum, R.P.

    2007-01-01

    Gallium-68 is a metallic positron emitter with a half-life of 68 min that is ideal for the in vivo use of small molecules, such as [ 68 Ga-DOTA,Tyr 3 ]octreotide, in the diagnostic imaging of somatostatin receptor-positive tumours. In preclinical studies it has shown a striking superiority over its 111 In-labelled congener. The purpose of this study was to evaluate whether third-generation somatostatin-based, radiogallium-labelled peptides show the same superiority. Peptides were synthesised on solid phase. The receptor affinity was determined by in vitro receptor autoradiography. The internalisation rate was studied in AR4-2J and hsst-HEK-transfected cell lines. The pharmacokinetics was studied in a rat xenograft tumour model, AR4-2J. All peptides showed high affinities on hsst2, with the highest affinity for the Ga III -complexed peptides. On hsst3 the situation was reversed, with a trend towards lower affinity of the Ga III peptides. A significantly increased internalisation rate was found in sst2-expressing cells for all 67 Ga-labelled peptides. Internalisation into HEK-sst3 was usually faster for the 111 In-labelled peptides. No internalisation was found into sst5. Biodistribution studies employing [ 67 Ga-DOTA,1-Nal 3 ]octreotide in comparison to [ 111 In-DOTA,1-Nal 3 ]octreotide and [ 67 Ga-DOTA,Tyr 3 ]octreotide showed a significantly higher and receptor-mediated uptake of the two 67 Ga-labelled peptides in the tumour and somatostatin receptor-positive tissues. A patient study illustrated the potential advantage of a broad receptor subtype profile radiopeptide over a high-affinity sst2-selective radiopeptide. This study demonstrates that 67/68 Ga-DOTA-octapeptides show distinctly better preclinical, pharmacological performances than the 111 In-labelled peptides, especially on sst2-expressing cells and the corresponding animal models. They may be excellent candidates for further development for clinical studies. (orig.)

  5. High emittance black nickel coating on copper substrate for space applications

    Energy Technology Data Exchange (ETDEWEB)

    Somasundaram, Soniya, E-mail: jrf0013@isac.gov.in; Pillai, Anju M., E-mail: anjum@isac.gov.in; Rajendra, A., E-mail: rajendra@isac.gov.in; Sharma, A.K., E-mail: aks@isac.gov.in

    2015-09-15

    Highlights: • High emittance black nickel coating is obtained on copper substrate. • The effect of various process parameters on IR emittance is studied systematically. • Process parameters are optimized to develop a high emittance black nickel coating. • Coating obtained using the finalized parameters exhibited an emittance of 0.83. • SEM and EDAX are used for coating characterization. - Abstract: Black nickel, an alloy coating of zinc and nickel, is obtained on copper substrate by pulse electrodeposition from a modified Fishlock bath containing nickel sulphate, nickel ammonium sulphate, zinc sulphate and ammonium thiocyanate. A nickel undercoat of 4–5 μm thickness is obtained using Watts bath to increase the corrosion resistance and adhesion of the black nickel coating. The effect of bath composition, temperature, solution pH, current density and plating time on the coating appearance and corresponding infra-red emittance of the coating is investigated systematically. Process parameters are optimized to develop a high emittance space worthy black nickel coating to improve the heat radiation characteristics. The effect of the chemistry of the plating bath on the coating composition was studied using energy dispersive X-ray analysis (EDAX) of the coatings. The 5–6 μm thick uniform jet black zinc–nickel alloy coating obtained with optimized process exhibited an emittance of 0.83 and an absorbance of 0.92. The zinc to nickel ratio of black nickel coatings showing high emittance and appealing appearance was found to be in the range 2.3–2.4.

  6. Rhenium 188 labelling of peptide conjugates

    International Nuclear Information System (INIS)

    Melendez-Alafort, Laura

    2001-01-01

    Many human tumours express high levels, of somatostatin receptors. In order to make possible a radiotherapeutic treatment of this kind for tumour a series of somatostatin analogues that can tightly chelate beta emitting isotopes have been developed in recent years. The work carried out for this thesis has been aimed towards development of a new therapeutic radiopharmaceutical for treatment of somatostatin receptor positive tumours. The first chapters describe work with technetium-99m to establish the labelling and analytical conditions for a somatostatin analogue, [Tyr 3 ]-octreotide (TOC), as a precursor to undertaking labelling studies with the beta emitter rhenium-188. 6-Hydrazinopyridine-3-carboxylic acid (HYNIC) was conjugated to TOC and labelled with 99m using different coligands. Then the stability, receptor binding and biodistribution of each complex were assessed. 99m Tc-HYNIC-TOC using EDDA as coligand showed the best characteristics, and was superior for tumour imaging in humans than the commercially available 111 In-DTPA-octreotide. The conditions for labelling the HYNIC-TOC conjugate with 188 Re were then optimised using tricine as a co-ligand. A labelling yield of ∼80% was achieved. After purification however, the stability of the complex was low. The use of other coligand systems which had proved useful for 99m Tc labelling was explored, but yields were very poor. Other chelators such as diethylenetriamine pentaacetic acid (DTPA), dimercaptosuccinic acid (DMSA) and mercaptoacetyltriglycine (MAG 3 ) were studied as potential co-ligand agents to label the HYNIC-TOC conjugate with 188 Re but, again low yields of the labelled peptide complexes were achieved. A novel 188 Re-HYNIC complex was prepared in high yields using N-N-disubstituted dithiocarbamates as coligands. However to date, the specific activities achieved with this system are relatively low. The use of the [ 99m Tc(CO) 3 (H 2 O) 3 ] complex to label the HYNIC-TOC conjugate was investigated

  7. High-resolution tomography of positron emitters with clustered pinhole SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Goorden, Marlies C; Beekman, Freek J [Section of Radiation Detection and Medical Imaging, Applied Sciences, Delft University of Technology, Mekelweg 15, 2629 JB Delft (Netherlands)], E-mail: m.c.goorden@tudelft.nl

    2010-03-07

    State-of-the-art small-animal single photon emission computed tomography (SPECT) enables sub-half-mm resolution imaging of radio-labelled molecules. Due to severe photon penetration through pinhole edges, current multi-pinhole SPECT is not suitable for high-resolution imaging of photons with high energies, such as the annihilation photons emitted by positron emitting tracers (511 keV). To deal with this edge penetration, we introduce here clustered multi-pinhole SPECT (CMP): each pinhole in a cluster has a narrow opening angle to reduce photon penetration. Using simulations, CMP is compared with (i) a collimator with traditional pinholes that is currently used for sub-half-mm imaging of SPECT isotopes (U-SPECT-II), and (ii), like (i) but with collimator thickness adapted to image high-energy photons (traditional multi-pinhole SPECT, TMP). At 511 keV, U-SPECT-II is able to resolve the 0.9 mm rods of an iteratively reconstructed Jaszczak-like capillary hot rod phantom, and while TMP only leads to small improvements, CMP can resolve rods as small as 0.7 mm. Using a digital tumour phantom, we show that CMP resolves many details not assessable with standard USPECT-II and TMP collimators. Furthermore, CMP makes it possible to visualize uptake of positron emitting tracers in sub-compartments of a digital mouse striatal brain phantom. This may open up unique possibilities for analysing processes such as those underlying the function of neurotransmitter systems. Additional potential of CMP may include (i) the imaging of other high-energy single-photon emitters (e.g. I-131) and (ii) localized imaging of positron emitting tracers simultaneously with single photon emitters, with an even better resolution than coincidence PET.

  8. Emittance measuring unit for 100% duty factor linac injector beams

    Energy Technology Data Exchange (ETDEWEB)

    Shubaly, M R; Pachner, J Jr; Ormrod, J H; Ungrin, J; Schriber, S O [ed.

    1976-11-01

    A description is given of a system to measure the emittance of a 750 keV 100 mA dc proton beam suitable for injection into a 100% duty factor linear accelerator. A relatively slowly pulsed 45/sup 0/ magnet switches the beam to a beam dump inside the emittance measuring unit for approx. 10 s. A fast pulsed 5/sup 0/ magnet then deflects the beam to a multiple aperture ''pepper-pot'' plate for 300 ..mu..s. Beamlets passing through the plate travel 520 mm and produce a pattern on a scintillator screen. A photograph of the pattern is analyzed to determine beam emittance. Preliminary results on low current beams show a gross increase in the emittance in the horizontal plane.

  9. An Online Multisensor Data Fusion Framework for Radar Emitter Classification

    Directory of Open Access Journals (Sweden)

    Dongqing Zhou

    2016-01-01

    Full Text Available Radar emitter classification is a special application of data clustering for classifying unknown radar emitters in airborne electronic support system. In this paper, a novel online multisensor data fusion framework is proposed for radar emitter classification under the background of network centric warfare. The framework is composed of local processing and multisensor fusion processing, from which the rough and precise classification results are obtained, respectively. What is more, the proposed algorithm does not need prior knowledge and training process; it can dynamically update the number of the clusters and the cluster centers when new pulses arrive. At last, the experimental results show that the proposed framework is an efficacious way to solve radar emitter classification problem in networked warfare.

  10. Transverse emittance dilution due to coupler kicks in linear accelerators

    Directory of Open Access Journals (Sweden)

    Brandon Buckley

    2007-11-01

    Full Text Available One of the main concerns in the design of low emittance linear accelerators (linacs is the preservation of beam emittance. Here we discuss one possible source of emittance dilution, the coupler kick, due to transverse electromagnetic fields in the accelerating cavities of the linac caused by the power coupler geometry. In addition to emittance growth, the coupler kick also produces orbit distortions. It is common wisdom that emittance growth from coupler kicks can be strongly reduced by using two couplers per cavity mounted opposite each other or by having the couplers of successive cavities alternate from above to below the beam pipe so as to cancel each individual kick. While this is correct, including two couplers per cavity or alternating the coupler location requires large technical changes and increased cost for superconducting cryomodules where cryogenic pipes are arranged parallel to a string of several cavities. We therefore analyze consequences of alternate coupler placements. We show here that alternating the coupler location from above to below compensates the emittance growth as well as the orbit distortions. For sufficiently large Q values, alternating the coupler location from before to after the cavity leads to a cancellation of the orbit distortion but not of the emittance growth, whereas alternating the coupler location from before and above to behind and below the cavity cancels the emittance growth but not the orbit distortion. We show that cancellations hold for sufficiently large Q values. These compensations hold even when each cavity is individually detuned, e.g., by microphonics. Another effective method for reducing coupler kicks that is studied is the optimization of the phase of the coupler kick so as to minimize the effects on emittance from each coupler. This technique is independent of the coupler geometry but relies on operating on crest. A final technique studied is symmetrization of the cavity geometry in the

  11. Emittance and trajectory control in the main linacs of the NLC

    International Nuclear Information System (INIS)

    Assmann, R.; Adolphsen, C.; Bane, K.; Raubenheimer, T.O.; Thompson, K.

    1996-09-01

    The main linacs of the next generation of linear colliders need to accelerate the particle beams to energies of up to 750 GeV while maintaining very small emittances. This paper describes the main mechanisms of static emittance growth in the main linacs of the Next Linear Collider (NLC). The authors present detailed simulations of the trajectory and emittance control algorithms that are foreseen for the NLC. They show that the emittance growth in the main linacs can be corrected down to about 110%. That number is significantly better than required for the NLC design luminosity

  12. Internal dynamics and emittance growth in space-charge-dominated beams

    International Nuclear Information System (INIS)

    Anderson, O.A.

    1987-01-01

    Previous analytical studies have related transverse rms emittance growth in nonuniform beams to changes in the beam density profile, but the time evolution of the process has not been analyzed. Our new approach analyzes the internal motion of the beam and from this obtains the explicit time dependence of the rms emittance. It is shown to reach its peak value explosively in about one quarter of a plasma period. The subsequent behavior depends on the uniformity of the initial density profile. We derive a uniformity criterion that determines whether or not the emittance oscillates periodically and present examples of density profiles for which the emittance returns to its initial value and then continues to oscillate. We discuss a class of continuous initial profiles that lead to discontinuous shocklike behavior (with partial irreversibility of the oscillations) and a class of segmented profiles for which the emittance jumps to its maximum value in one fourth of a plasma period and remains at that value with essentially no further change. (author)

  13. 49 CFR 40.213 - What training requirements must STTs and BATs meet?

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false What training requirements must STTs and BATs meet? 40.213 Section 40.213 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Alcohol Testing Personnel § 40.213 What training requirements must STTs and BATs meet? To be...

  14. 45 CFR 213.5 - Filing and service of papers.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 2 2010-10-01 2010-10-01 false Filing and service of papers. 213.5 Section 213.5... and service of papers. (a) All papers in the proceedings shall be filed with the FSA Hearing Clerk, in...) All papers in the proceedings shall be served on all parties by personal delivery or by mail. Service...

  15. Modular low-voltage electron emitters

    International Nuclear Information System (INIS)

    Berejka, Anthony J.

    2005-01-01

    Modular, low-voltage electron emitters simplify electron beam (EB) technology for many industrial uses and for research and development. Modular electron emitters are produced in quantity as sealed systems that are evacuated at the factory, eliminating the need for vacuum pumps at the point of use. A plug-out-plug-in method of replacement facilitates servicing. By using an ultra-thin 6-7 μm titanium foil window, solid-state power supplies, an innovative design to extract and spread the beam (enabling systems to be placed adjacent to each other to extend beam width) and touch-screen computer controls, these modular units combine ease of use and electrical transfer efficiency at voltages that can be varied between 80 kV and 150 kV with beam currents up to 40 mA per 25 cm across the beam window. These new devices have been made in three widths: 5 cm, 25 cm, and 40 cm. Details of the beam construction and illustrations of industrial uses will be presented. Traditional uses in the graphic arts and coatings areas have welcomed this modular technology as well as uses for surface sterilization. Being compact and lightweight (∼15 kg/emitter), these modular beams have been configured around complex shapes to achieve three-dimensional surface curing at high production rates

  16. Modular low-voltage electron emitters

    Science.gov (United States)

    Berejka, Anthony J.

    2005-12-01

    Modular, low-voltage electron emitters simplify electron beam (EB) technology for many industrial uses and for research and development. Modular electron emitters are produced in quantity as sealed systems that are evacuated at the factory, eliminating the need for vacuum pumps at the point of use. A plug-out-plug-in method of replacement facilitates servicing. By using an ultra-thin 6-7 μm titanium foil window, solid-state power supplies, an innovative design to extract and spread the beam (enabling systems to be placed adjacent to each other to extend beam width) and touch-screen computer controls, these modular units combine ease of use and electrical transfer efficiency at voltages that can be varied between 80 kV and 150 kV with beam currents up to 40 mA per 25 cm across the beam window. These new devices have been made in three widths: 5 cm, 25 cm, and 40 cm. Details of the beam construction and illustrations of industrial uses will be presented. Traditional uses in the graphic arts and coatings areas have welcomed this modular technology as well as uses for surface sterilization. Being compact and lightweight (∼15 kg/emitter), these modular beams have been configured around complex shapes to achieve three-dimensional surface curing at high production rates.

  17. Beam dynamics in rf guns and emittance correction techniques

    International Nuclear Information System (INIS)

    Serafini, L.

    1994-01-01

    In this paper we present a general review of beam dynamics in a laser-driven rf gun. The peculiarity of such an accelerating structure versus other conventional multi-cell linac structures is underlined on the basis of the Panofsky-Wenzel theorem, which is found to give a theoretical background for the well known Kim's model. A basic explanation for some proposed methods to correct rf induced emittance growth is also derived from the theorem. We also present three emittance correction techniques for the recovery of space-charge induced emittance growth, namely the optimum distributed disk-like bunch technique, the use of rf spatial harmonics to correct spherical aberration induced by space charge forces and the technique of emittance filtering by clipping the electron beam. The expected performances regarding the beam quality achievable with different techniques, as predicted by scaling laws and simulations, are analyzed, and, where available, compared to experimental results. (orig.)

  18. Transverse emittance measurement at REGAE via a solenoid scan

    Energy Technology Data Exchange (ETDEWEB)

    Hachmann, Max

    2012-12-15

    The linear accelerator REGAE at DESY produces short and low charged electron bunches, on the one hand to resolve the excitation transitions of atoms temporally by pump probe electron diffraction experiments and on the other hand to investigate principal mechanisms of laser plasma acceleration. For both cases a high quality electron beam is required. A quantity to rate the beam quality is the beam emittance. In the course of this thesis transverse emittance measurements by a solenoid scan could be realized and beyond that an improved theoretical description of a solenoid was successful. The foundation of emittance measurements are constituted by theoretical models which describe the envelope of a beam. Two different models were derived. The first is an often used model to determine the transverse beam emittance without considering space charge effects. More interesting and challenging was the development of an envelope model taking space charge effects into account. It is introduced and cross checked with measurements and simulations.

  19. Preparation and preclinical evaluation of 211At-labelled compounds for α-particle radiotherapy

    International Nuclear Information System (INIS)

    Larsen, R.H.

    1994-01-01

    The present work demonstrate that significant therapeutic gain can be achieved with 211 At-labelled MoAbs on single tumour cells and microscopic disease. Β-emitters are less effective on microscopic disease because of radiation dispersion, while longer halflives (e.g., 90 Y and 131 I) allow favourable therapeutic ratios to be reached in larger tumors. 211 At-labelled MoAbs may therefore possibly be used in combination with β-emitting RIC in systemically delivered radioimunnotherapy. Larger tumor nodules are then irradiated effectively due to cross-fire of the longer ranged β-particles while the fraction of tumour cells distributed as single cells and micrometastases may be more effectively radiated with 211 At-RIC. 76 refs

  20. Which radionuclide, carrier molecule and clinical indication for alpha-immunotherapy?

    International Nuclear Information System (INIS)

    Guerard, F.; Barbet, J.; Cherel, M.; Chatal, J.-F.; Haddad, F.; Kraeber-Bodere, F.

    2015-01-01

    Beta-emitting radionuclides are not able to kill isolated tumor cells disseminated in the body, even if a high density of radiolabeled molecules can be targeted at the surface of these cells because the vast majority of emitted electrons deliver their energy outside the targeted cells. Alpha-particle emitting radionuclides may overcome this limitation. It is thus of primary importance to test and validate the radionuclide of choice, the most appropriate carrier molecule and the most promising clinical indication. Four α-particle emitting radionuclides have been or are clinically tested in phase I studies namely 213 Bi, 225 Ac, 212 Pb and 211 At. Clinical safety has been documented and encouraging efficacy has been shown for some of them ( 213 Bi and 211 At). 211 At has been the most studied and could be the most promising radionuclide but 225 Ac and 212 Pb are also of potential great interest. Any carrier molecule that has been labeled with β-emitting radionuclides could be labeled with alpha particle-emitting radionuclide using, for some of them, the same chelating agents. However, the physical half-life of the radionuclide should match the biological half-life of the radioconjugate or its catabolites. Finally everybody agrees, based on the quite short range of alpha particles, on the fact that the clinical indications for alpha-immunotherapy should be limited to the situation of disseminated minimal residual diseases made of small clusters of malignant cells or isolated tumor cells.

  1. Laser-assisted electron emission from gated field-emitters

    CERN Document Server

    Ishizuka, H; Yokoo, K; Mimura, H; Shimawaki, H; Hosono, A

    2002-01-01

    Enhancement of electron emission by illumination of gated field-emitters was studied using a 100 mW cw YAG laser at a wavelength of 532 nm, intensities up to 10 sup 7 W/m sup 2 and mechanically chopped with a rise time of 4 mu s. When shining an array of 640 silicon emitters, the emission current responded quickly to on-off of the laser. The increase of the emission current was proportional to the basic emission current at low gate voltages, but it was saturated at approx 3 mu A as the basic current approached 100 mu A with the increase of gate voltage. The emission increase was proportional to the square root of laser power at low gate voltages and to the laser power at elevated gate voltages. For 1- and 3-tip silicon emitters, the rise and fall of the current due to on-off of the laser showed a significant time lag. The magnitude of emission increase was independent of the position of laser spot on the emitter base and reached 2 mu A at a basic current of 5 mu A without showing signs of saturation. The mech...

  2. Facile synthesis of Bi/BiOCl composite with selective photocatalytic properties

    International Nuclear Information System (INIS)

    Chen, Dongling; Zhang, Min; Lu, Qiuju; Chen, Junfang; Liu, Bitao; Wang, Zhaofeng

    2015-01-01

    This paper presents a novel and facile method to fabricate Bi/BiOCl composites with dominant (001) facets in situ via a microwave reduction route. Different characterization techniques, including X-ray diffraction (XRD), field-emission scanning electron microscopy (FE-SEM), transmission scanning electron microscopy (TEM), UV–vis diffuse reflectance spectrometry (DRS), X-ray photoelectron spectroscopy (XPS), electron spin resonance spectroscopy (ESR), cathodoluminescence spectrum (CL), and lifetime, have been employed to investigate the structure, optical and electrical properties of the Bi/BiOCl composites. The experimental results show that the introduction of Bi particles can efficiently enhance the photocatalytic performance of BiOCl for the degradation of several dyes under ultraviolet (UV) light irradiation, especially for negative charged methyl orange (MO). Unlike the UV photocatalytic performance, such Bi/BiOCl composite shows higher degradation efficiency towards rhodamine B (RhB) than MO and methylene blue (MB) under visible light irradiation. This special photocatalytic performance can be ascribed to the synergistic effect between oxygen vacancies and Bi particles. This work provides new insights about the photodegradation mechanisms of MO, MB and RhB under UV and visible light irradiation, which would be helpful to guide the selection of an appropriate catalyst for other pollutants. - Highlights: • Bi/BiOCl composites were synthesized via a microwave reduction. • Tunable selectivity photocatalytic activity can be achieved. • Photodegradation mechanism under UV and visible light were proposed

  3. 47 CFR 213.4 - Definitions.

    Science.gov (United States)

    2010-10-01

    ... Telecommunication OFFICE OF SCIENCE AND TECHNOLOGY POLICY AND NATIONAL SECURITY COUNCIL GOVERNMENT AND PUBLIC CORRESPONDENCE TELECOMMUNICATIONS PRECEDENCE SYSTEM § 213.4 Definitions. As used herein: (a) Public... which messages and calls are processed. Transmission of information and call completion is therefore to...

  4. Imaging of HER2/neu-positive BT-474 human breast cancer xenografts in athymic mice using 111In-trastuzumab (Herceptin) Fab fragments

    International Nuclear Information System (INIS)

    Tang Ying; Wang, Judy; Scollard, Deborah A.; Mondal, Hridya; Holloway, Claire; Kahn, Harriette J.; Reilly, Raymond M.

    2005-01-01

    Trastuzumab (Herceptin) Fab were prepared by digestion of intact IgG with immobilized papain, derivatized with diethylenetriaminepentaacetic acid (DTPA) and radiolabeled with 111 In. The dissociation constant (K d ) for binding of Fab to HER2/neu-positive SK-BR-3 human breast cancer cells was two- to threefold higher than for intact IgG (14-36 vs. 8-14 nM). The binding affinity was not significantly decreased after DTPA derivatization (K d =47 nM). 111 In-trastuzumab Fab localized specifically in HER2/neu-positive BT-474 human breast cancer xenografts in athymic mice with tumor uptake of 7.8±0.7% injected dose (ID)/g and tumor/blood ratio of 25.2±1.6 at 72 h postinjection compared with 2.7±0.7% ID/g and 7.0±0.9 for 111 In-HuM195 anti-CD33 Fab (significantly different, P 111 In-trastuzumab Fab as early as 24 h postinjection

  5. Highly spatially resolved structural and optical investigation of Bi nanoparticles in Y-Er disilicate thin films

    Energy Technology Data Exchange (ETDEWEB)

    Scarangella, A. [CNR IMM-MATIS, Via S. Sofia 64, 95123 Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Via S. Sofia 64, 95123 Catania (Italy); Amiard, G.; Boninelli, S., E-mail: simona.boninelli@ct.infn.it; Miritello, M. [CNR IMM-MATIS, Via S. Sofia 64, 95123 Catania (Italy); Reitano, R. [Dipartimento di Fisica e Astronomia, Università di Catania, Via S. Sofia 64, 95123 Catania (Italy); Priolo, F. [CNR IMM-MATIS, Via S. Sofia 64, 95123 Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Via S. Sofia 64, 95123 Catania (Italy); Scuola Superiore di Catania, Università di Catania, Via Valdisavoia 9, 95123 Catania (Italy)

    2016-08-08

    Er-containing silicon compatible materials have been widely used as infrared emitters for microphotonics application. In this field, the additional introduction of a proper sensitizer permits to increase the Er excitation cross sections, thus increasing its optical efficiency. This work aims to investigate the influence of a post-transition metal, bismuth, on the optical properties of erbium-yttrium disilicate thin films synthesized by magnetron co-sputtering. After thermal treatments at 1000 °C in O{sub 2} or N{sub 2} environment, the presence of small precipitates, about 6 nm in diameter, was evidenced by transmission electron microscopy analyses. The spatially resolved chemical nature of the nanoparticles was discerned in the Si and O rich environments by means of scanning transmission electron microscopy–energy dispersive X-ray and scanning transmission electron microscopy–electron energy loss spectroscopy analyses performed with nanometric resolution. In particular, metallic Bi nanoparticles were stabilized in the N{sub 2} environment, being strongly detrimental for the Er emission. A different scenario was instead observed in O{sub 2}, where the formation of Bi silicate nanoparticles was demonstrated with the support of photoluminescence excitation spectroscopy. In particular, a broad band peaked at 255 nm, correlated to the excitation band of Bi silicate nanoparticles, was identified in Er excitation spectrum. Thus Bi silicate clusters act as sensitizer for Er ions, permitting to improve Er emission up to 250 times with respect to the resonant condition. Moreover, the Er decay time increases in the presence of the Bi silicate nanoparticles that act as cages for Er ions. These last results permit to further increase Er optical efficiency in the infrared range, suggesting (Bi + Er)-Y disilicate as a good candidate for applications in microphotonics.

  6. Preservation of low slice emittance in bunch compressors

    Directory of Open Access Journals (Sweden)

    S. Bettoni

    2016-03-01

    Full Text Available Minimizing the dilution of the electron beam emittance is crucial for the performance of accelerators, in particular for free electron laser facilities, where the length of the machine and the efficiency of the lasing process depend on it. Measurements performed at the SwissFEL Injector Test Facility revealed an increase in slice emittance after compressing the bunch even for moderate compression factors. The phenomenon was experimentally studied by characterizing the dependence of the effect on beam and machine parameters relevant for the bunch compression. The reproduction of these measurements in simulation required the use of a 3D beam dynamics model along the bunch compressor that includes coherent synchrotron radiation. Our investigations identified transverse effects, such as coherent synchrotron radiation and transverse space charge as the sources of the observed emittance dilution, excluding other effects, such as chromatic effects on single slices or spurious dispersion. We also present studies, both experimental and simulation based, on the effect of the optics mismatch of the slices on the variation of the slice emittance along the bunch. After a corresponding reoptimization of the beam optics in the test facility we reached slice emittances below 200 nm for the central slices along the longitudinal dimension with a moderate increase up to 300 nm in the head and tail for a compression factor of 7.5 and a bunch charge of 200 pC, equivalent to a final current of 150 A, at about 230 MeV energy.

  7. Coupling of Quantum Emitters in Nanodiamonds to Plasmonic Structures

    DEFF Research Database (Denmark)

    Kumar, Shailesh

    This PhD thesis describes work towards the enhancement and efficient channeling of photons emitted from a single photon emitter. The emitter used is a defect center, the Nitrogen-Vacancy (NV) center, in diamond. The NV-center has many unique properties, such as long coherence time of its electron...

  8. Bismuth-boron multiple bonding in BiB_2O"- and Bi_2B"-

    International Nuclear Information System (INIS)

    Jian, Tian; Cheung, Ling Fung; Chen, Teng-Teng; Wang, Lai-Sheng

    2017-01-01

    Despite its electron deficiency, boron is versatile in forming multiple bonds. Transition-metal-boron double bonding is known, but boron-metal triple bonds have been elusive. Two bismuth boron cluster anions, BiB_2O"- and Bi_2B"-, containing triple and double B-Bi bonds are presented. The BiB_2O"- and Bi_2B"- clusters are produced by laser vaporization of a mixed B/Bi target and characterized by photoelectron spectroscopy and ab initio calculations. Well-resolved photoelectron spectra are obtained and interpreted with the help of ab initio calculations, which show that both species are linear. Chemical bonding analyses reveal that Bi forms triple and double bonds with boron in BiB_2O"- ([Bi≡B-B≡O]"-) and Bi_2B"- ([Bi=B=Bi]"-), respectively. The Bi-B double and triple bond strengths are calculated to be 3.21 and 4.70 eV, respectively. This is the first experimental observation of Bi-B double and triple bonds, opening the door to design main-group metal-boron complexes with multiple bonding. (copyright 2017 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  9. The modulation and reconstruction of a BiO layer of cuprate Bi2212

    International Nuclear Information System (INIS)

    Fan Wei; Zeng, Z

    2011-01-01

    Studies based on ab initio density functional theory show that the modulated structures of BiO surfaces of cuprate Bi2212 superconductors are spontaneously formed and closely related to the reconstructions of BiO surfaces. The reconstructions of BiO layers occur both on the surface and in the bulk, accompanied with the formations of BiO-zigzag chains and Bi 2 O 2 quadrilaterals. The structural modulations of the BiO surface are along the b axis, perpendicular to the BiO-zigzag chains along the a axis. Our calculations provide a unified understanding of the formation of modulating structures in Bi2212. Another interesting result is that electronic structures of BiO surfaces are significantly influenced by the CuO 2 layer beneath because of the structural modulations and reconstructions.

  10. Novel Bi/BiOBr/AgBr composite microspheres: Ion exchange synthesis and photocatalytic performance

    Science.gov (United States)

    Lyu, Jianchang; Li, Zhenlu; Ge, Ming

    2018-06-01

    Novel Bi/BiOBr/AgBr composite microspheres were prepared by a rational in situ ion exchange reaction between Bi/BiOBr microspheres and AgNO3. The characteristic of the as-obtained ternary microspheres was tested by X-ray diffraction (XRD), energy dispersive X-ray spectrometer (EDS), scanning electron microscope (SEM), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), UV-vis diffuse reflectance spectroscopy (UV-vis DRS) and photoluminescence (PL). Under visible light irradiation, Bi/BiOBr/AgBr microspheres exhibited an excellent photocatalytic efficiency for rhodamine B (RhB) degradation, which was about 1.4 and 4.9 times as high as that of Bi/BiOBr and BiOBr/AgBr, demonstrating that the highest separation efficiency of charge carriers in the heterostructured Bi/BiOBr/AgBr. The photocatalytic activity of Bi/BiOBr/AgBr microspheres just exhibited a slight decrease after three consecutive cycles. The photocatalytic mechanism investigation confirmed that the superoxide radicals (O2•-) were the dominant reactive oxygen species for RhB degradation in Bi/BiOBr/AgBr suspension.

  11. Emittance growth due to dipole ripple and sextupole

    International Nuclear Information System (INIS)

    Shih, H.J.; Ellison, J.A.; Syphers, M.J.; Newberger, B.S.

    1993-05-01

    Ripple in the power supplies for storage ring magnets can have adverse effects on the circulating beams: orbit distortion and emittance growth from dipole ripple, tune modulation and dynamic aperture reduction from quadrupole ripple, etc. In this paper, we study the effects of ripple in the horizontal bending field of the SSC in the presence of nonlinearity, in particular, the growth in beam emittance

  12. 22 CFR 213.3 - Loans, guarantees, sovereign and interagency claims.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Loans, guarantees, sovereign and interagency claims. 213.3 Section 213.3 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT CLAIMS COLLECTION... thereof, or any public international organization; (d) Claims where the CFO determines that the...

  13. 19 CFR 213.4 - Disclosure of receipt of technical assistance.

    Science.gov (United States)

    2010-04-01

    ....4 Section 213.4 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION INVESTIGATIONS OF UNFAIR PRACTICES IN IMPORT TRADE TRADE REMEDY ASSISTANCE § 213.4 Disclosure of receipt of technical assistance. An... received technical assistance from the Trade Remedy Assistance Office in any resulting petition, complaint...

  14. Photocatalytic activity of Bi_2WO_6/Bi_2S_3 heterojunctions: the facilitation of exposed facets of Bi_2WO_6 substrate

    International Nuclear Information System (INIS)

    Yan, Long; Wang, Yufei; Shen, Huidong; Zhang, Yu; Li, Jian; Wang, Danjun

    2017-01-01

    Highlights: • Bi_2S_3/Bi_2WO_6 hybrids with exposed (020) Bi_2WO_6 facets have been synthesized. • X-ray photoelectron spectroscopy reveals that a small amount of Bi_2S_3 was formed. • The enhanced photoactivity of hybrids is due to heterojunction and (020) facets. • A possible photocatalytic degradation mechanism is proposed. - Abstract: Bi_2S_3/Bi_2WO_6 hybrid architectures with exposed (020) Bi_2WO_6 facets have been synthesized via a controlled anion exchange approach. X-ray photoelectron spectroscopy (XPS) reveals that a small amount of Bi_2S_3 was formed on the surface of Bi_2WO_6 during the anion exchange process, thus leading to the transformation from the Bi_2WO_6 to Bi_2S_3/Bi_2WO_6. A rhodamine B (RhB) aqueous solution was chosen as model organic pollutants to evaluate the photocatalytic activities of the Bi_2S_3/Bi_2WO_6 catalysts. Under visible light irradiation, the Bi_2S_3/Bi_2WO_6-TAA displayed the excellent visible light photoactivities compared with pure Bi_2S_3, Bi_2WO_6 and other composite photocatalysts. The efficient photocatalytic activity of the Bi_2S_3/Bi_2WO_6-TAA composite microspheres was ascribed to the constructed heterojunctions and the inner electric field caused by the exposed (020) Bi_2WO_6 facets. Active species trapping experiments revealed that h"+ and O_2·"− are the main active species in the photocatalytic process. Furthermore, the as-obtained photocatalysts showed good photocatalytic activity after four recycles. The results presented in this study provide a new concept for the rational design and development of highly efficient photocatalysts.

  15. Recent advances in the chemistry of positron emitters

    International Nuclear Information System (INIS)

    Wolf, A.P.; Fowler, J.S.

    1985-01-01

    With the increasing active interest in PET as a method for studying biochemistry in normal and pathological states in humans we can expect to see the development of new techniques for precursor preparation and synthesis. We have seen a doubling of the publication rate in the past three to four years over the previous three to four year period. As the need for these compounds, especially in the tumor and receptor areas, in a purely clinical setting, increases the trend towards true automation of production of the most needeed compounds will accelerate. The cyclotron manufacturers all offer ''black boxes'' for synthesis but the optimum approach to user friendly automation yet needs to be defined. I would note that this paper was not intended as a comprehensive review but rather my goal was to highlight just some of the exciting developments of the past several years. We are entering what may well be the most extensive and active period of research in the synthesis of positron emitter labeled compounds. If 1984 to 1985 is any gauge, many new methods and compounds will appear in the next several years. 37 refs

  16. Multibunch emittance growth and its corrections in S-Band linear collider

    International Nuclear Information System (INIS)

    Gao, J.

    1994-11-01

    Multibunch emittance growths caused by long range wake fields with the misalignments of accelerating structures and quadrupoles in S-Band linear collider are studied. Tolerances for the misalignment errors of accelerating structures and quadrupoles are given corresponding to different detuned+damped structures. At the end of main linac, emittance corrector (EC) is proposed to be used to reduce further the multibunch emittance. Numerical simulations show that the effect of EC is obvious (multibunch emittance can be reduced about one order of magnitude), and it is believed that this kind of EC will be necessary for future linear colliders. (author). 16 refs., 21 figs., 4 tabs

  17. Emittance Measurements from a Laser Driven Electron Injector

    Energy Technology Data Exchange (ETDEWEB)

    Reis, David A

    2003-07-28

    The Gun Test Facility (GTF) at the Stanford Linear Accelerator Center was constructed to develop an appropriate electron beam suitable for driving a short wavelength free electron laser (FEL) such as the proposed Linac Coherent Light Source (LCLS). For operation at a wavelength of 1.5 {angstrom}, the LCLS requires an electron injector that can produce an electron beam with approximately 1 {pi} mm-mrad normalized rms emittance with at least 1 nC of charge in a 10 ps or shorter bunch. The GTF consists of a photocathode rf gun, emittance-compensation solenoid, 3 m linear accelerator (linac), drive laser, and diagnostics to measure the beam. The rf gun is a symmetrized 1.6 cell, s-band high gradient, room temperature, photocathode structure. Simulations show that this gun when driven by a temporally and spatially shaped drive laser, appropriately focused with the solenoid, and further accelerated in linac can produce a beam that meets the LCLS requirements. This thesis describes the initial characterization of the laser and electron beam at the GTF. A convolved measurement of the relative timing between the laser and the rf phase in the gun shows that the jitter is less than 2.5 ps rms. Emittance measurements of the electron beam at 35 MeV are reported as a function of the (Gaussian) pulse length and transverse profile of the laser as well as the charge of the electron beam at constant phase and gradient in both the gun and linac. At 1 nC the emittance was found to be {approx} 13 {pi} mm-mrad for 5 ps and 8 ps long laser pulses. At 0.5 nC the measured emittance decreased approximately 20% in the 5 ps case and 40% in the 8 ps case. These measurements are between 40-80% higher than simulations for similar experimental conditions. In addition, the thermal emittance of the electron beam was measured to be 0.5 {pi} mm-mrad.

  18. Quadrupole Transfer Function for Emittance Measurement

    CERN Document Server

    Cameron, Peter; Jansson, Andreas; Tan, Cheng-Yang

    2008-01-01

    Historically the use of the quadrupole moment measurement has been impeded by the requirement for large dynamic range, as well as measurement sensitivity to beam position. We investigate the use of the transfer function technique [1-3] in combination with the sensitivity and 160dB revolution line rejection of the direct diode detection analog front end [4] to open the possibility of an emittance diagnostic that may be implemented without operational complication, quasi- parasitic to the operation of existing tune measurement systems. Such a diagnostic would be particularly useful as an emittance monitor during acceleration ramp development in machines like RHIC and the LHC.

  19. Emitter/absorber interface of CdTe solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Song, Tao, E-mail: tsong241@gmail.com; Sites, James R. [Physics Department, Colorado State University, Fort Collins, Colorado 80523 (United States); Kanevce, Ana [National Renewable Energy Laboratory, Golden, Colorado 80401 (United States)

    2016-06-21

    The performance of CdTe solar cells can be very sensitive to the emitter/absorber interface, especially for high-efficiency cells with high bulk lifetime. Performance losses from acceptor-type interface defects can be significant when interface defect states are located near mid-gap energies. Numerical simulations show that the emitter/absorber band alignment, the emitter doping and thickness, and the defect properties of the interface (i.e., defect density, defect type, and defect energy) can all play significant roles in the interface recombination. In particular, a type I heterojunction with small conduction-band offset (0.1 eV ≤ ΔE{sub C} ≤ 0.3 eV) can help maintain good cell efficiency in spite of high interface defect density, much like with Cu(In,Ga)Se{sub 2} (CIGS) cells. The basic principle is that positive ΔE{sub C}, often referred to as a “spike,” creates an absorber inversion and hence a large hole barrier adjacent to the interface. As a result, the electron-hole recombination is suppressed due to an insufficient hole supply at the interface. A large spike (ΔE{sub C} ≥ 0.4 eV), however, can impede electron transport and lead to a reduction of photocurrent and fill-factor. In contrast to the spike, a “cliff” (ΔE{sub C} < 0 eV) allows high hole concentration in the vicinity of the interface, which will assist interface recombination and result in a reduced open-circuit voltage. Another way to mitigate performance losses due to interface defects is to use a thin and highly doped emitter, which can invert the absorber and form a large hole barrier at the interface. CdS is the most common emitter material used in CdTe solar cells, but the CdS/CdTe interface is in the cliff category and is not favorable from the band-offset perspective. The ΔE{sub C} of other n-type emitter choices, such as (Mg,Zn)O, Cd(S,O), or (Cd,Mg)Te, can be tuned by varying the elemental ratio for an optimal positive value of ΔE{sub C}. These

  20. Rapid labelling of radiopharmaceuticals using 11CO2 and 11CH4

    International Nuclear Information System (INIS)

    Crouzel, C.

    1988-07-01

    In the past two decades, much effort has been devoted to the development of new molecules, labelled with β+ emitters usable for Positron Emission Tomography. Gaseous forms of 11 C ( 11 CO 2 or 11 CH 4 ) must be converted to a reactive form known as a ''radioactive precursor'': 11 C-methanol, 11 C-formaldehyde, 11 C-acetone, 11 C-phosgene, 11 C-diazomethane, 11 C-methylamine. These precursors are used to label radiopharmaceuticals. Few examples are given: 11 C-prazosin, 11 C-CGP 12177, 11 C-pindolol. Such synthesis procedures require strong initial activity (1.5 Ci). The processes are therefore remotely controlled or automated, and confined to shielded cells. Small laboratory robots have lately been introduced for this type of production

  1. Heterojunction BiOI/Bi2MoO6 nanocomposite with much enhanced photocatalytic activity

    International Nuclear Information System (INIS)

    Li, Wen Ting; Zheng, Yi Fan; Yin, Hao Yong; Song, Xu Chun

    2015-01-01

    BiOI/Bi 2 MoO 6 heterostructures with different amounts of BiOI were successfully prepared via a facile deposition method. The obtained BiOI/Bi 2 MoO 6 photocatalysts exhibited much higher visible light (λ > 420 nm) induced photocatalytic activity compared with single Bi 2 MoO 6 and BiOI photocatalysts. 20 % BiOI/Bi 2 MoO 6 nanocomposite exhibited the highest photocatalytic activity with almost all RhB decomposed within 70 min. However, excess BiOI covering on the surface of Bi 2 MoO 6 can inversely reduce the photocatalytic activity. The enhanced photocatalytic activities could be resulted from the function of the novel p–n heterojunction interface between Bi 2 MoO 6 and BiOI, which could separate photoinduced carriers efficiently. Possible mechanisms on the basis of the relative band positions were also discussed

  2. Multiferroic BiFeO3-BiMnO3 Nanocheckerboard From First Principles

    OpenAIRE

    Palova, L.; Chandra, P.; Rabe, K. M.

    2010-01-01

    We present a first principles study of an unusual heterostructure, an atomic-scale checkerboard of BiFeO3-BiMnO3, and compare its properties to the two bulk constituent materials, BiFeO3 and BiMnO3. The "nanocheckerboard" is found to have a multiferroic ground state with the desired properties of each constituent: polar and ferrimagnetic due to BiFeO3 and BiMnO3, respectively. The effect of B-site cation ordering on magnetic ordering in the BiFeO3-BiMnO3 system is studied. The checkerboard ge...

  3. Ion concentration in micro and nanoscale electrospray emitters.

    Science.gov (United States)

    Yuill, Elizabeth M; Baker, Lane A

    2018-06-01

    Solution-phase ion transport during electrospray has been characterized for nanopipettes, or glass capillaries pulled to nanoscale tip dimensions, and micron-sized electrospray ionization emitters. Direct visualization of charged fluorophores during the electrospray process is used to evaluate impacts of emitter size, ionic strength, analyte size, and pressure-driven flow on heterogeneous ion transport during electrospray. Mass spectrometric measurements of positively- and negatively-charged proteins were taken for micron-sized and nanopipette emitters under low ionic strength conditions to further illustrate a discrepancy in solution-driven transport of charged analytes. A fundamental understanding of analyte electromigration during electrospray, which is not always considered, is expected to provide control over selective analyte depletion and enrichment, and can be harnessed for sample cleanup. Graphical abstract Fluorescence micrographs of ion migration in nanoscale pipettes while solution is electrosprayed.

  4. Emittance of a finite scattering medium with refractive index greater than unity

    International Nuclear Information System (INIS)

    Crosbie, A.L.

    1980-01-01

    Refractive index and scattering can significantly influence the transfer of radiation in a semitransparent medium such as water, glass, plastics, or ceramics. In a recent article (1979), the author presented exact numerical results for the emittance of a semiinfinite scattering medium with a refractive index greater than unity. The present investigation extends the analysis to a finite medium. The physical situation consists of a finite planar layer. The isothermal layer emits, absorbs, and isotropically scatters thermal radiation. It is characterized by single scattering albedo, optical thickness, refractive index, and temperature. A formula for the directional emittance is derived, the directional emittance being the emittance of the medium multiplied by the interface transmittance. The ratio of hemispherical to normal emittance is tabulated and discussed

  5. MD2065: Emittance exchange with linear coupling

    CERN Document Server

    Carver, Lee Robert; Persson, Tobias Hakan Bjorn; Amorim, David; Levens, Tom; Pesah, Arthur Chalom; CERN. Geneva. ATS Department

    2018-01-01

    In order to better understand the luminosity imbalance between ATLAS and CMS that was observed in 2016, it was proposed to perform a test whereby the horizontal and vertical emittances are exchanged by crossing the tunes in the presence of linear coupling. The luminosity before and after the exchange could be compared to see if the imbalance stems purely from the uneven emittances or if there is an additional mechanism in play. However, due to limited machine availability only tests at injection were able to performed.

  6. Prototype of a subsurface drip irrigation emitter: Manufacturing, hydraulic evaluation and experimental analyses

    Science.gov (United States)

    Souza, Wanderley De Jesus; Rodrigues Sinobas, Leonor; Sánchez, Raúl; Arriel Botrel, Tarlei; Duarte Coelho, Rubens

    2013-04-01

    Root and soil intrusion into the conventional emitters is one of the major disadvantages to obtain a good uniformity of water application in subsurface drip irrigation (SDI). In the last years, there have been different approaches to reduce these problems such as the impregnation of emitters with herbicide, and the search for an emitter geometry impairing the intrusion of small roots. Within the last this study, has developed and evaluated an emitter model which geometry shows specific physical features to prevent emitter clogging. This work was developed at the Biosystems Engineering Department at ESALQ-USP/Brazil, and it is a part of a research in which an innovated emitteŕs model for SDI has been developed to prevent root and soil particles intrusion. An emitter with a mechanical-hydraulic mechanism (opening and closing the water outlet) for SDI was developed and manufactured using a mechanical lathe process. It was composed by a silicon elastic membrane a polyethylene tube and a Vnyl Polychloride membrane protector system. In this study the performance of the developed prototype was assessed in the laboratory and in the field conditions. In the laboratory, uniformity of water application was calculated by the water emission uniformity coefficient (CUE), and the manufacturer's coefficient of variation (CVm). In addition, variation in the membrane diameter submitted to internal pressures; head losses along the membrane, using the energy equation; and, precision and accuracy of the equation model, analyzed by Pearson's correlation coefficient (r), and by Willmott's concordance index (d) were also calculated with samples of the developed emitters. In the field, the emitters were installed in pots with and without sugar cane culture from October 2010 to January 2012. During this time, flow rate in 20 emitters were measured periodically, and the aspects of them about clogging at the end of the experiment. Emitters flow rates were measured quarterly to calculate

  7. Synthesis of carbon-11, fluorine-18, and nitrogen-13 labeled radiotracers for biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, J.S.; Wolf, A.P.

    1981-01-01

    A number of reviews, many of them recent, have appeared on various aspects of /sup 11/C, /sup 18/F and /sup 13/N-labeled radiotracers. This monograph treats the topic principally from the standpoint of synthetic organic chemistry while keeping in perspective the necessity of integrating the organic chemistry with the design and ultimate application of the radiotracer. Where possible, recent examples from the literature of organic synthesis are introduced to suggest potentially new routes which may be applied to problems in labeling organic molecules with the short-lived positron emitters, carbon-11, fluorine-18, and nitrogen-13. The literature survey of carbon-11, fluorine-18 and nitrogen-13 labeled compounds presented are of particular value to scientists working in this field. Two appendices are also included to provide supplementary general references. A subject index concludes this volume.

  8. Synthesis of carbon-11, fluorine-18, and nitrogen-13 labeled radiotracers for biomedical applications

    International Nuclear Information System (INIS)

    Fowler, J.S.; Wolf, A.P.

    1981-01-01

    A number of reviews, many of them recent, have appeared on various aspects of 11 C, 18 F and 13 N-labeled radiotracers. This monograph treats the topic principally from the standpoint of synthetic organic chemistry while keeping in perspective the necessity of integrating the organic chemistry with the design and ultimate application of the radiotracer. Where possible, recent examples from the literature of organic synthesis are introduced to suggest potentially new routes which may be applied to problems in labeling organic molecules with the short-lived positron emitters, carbon-11, fluorine-18, and nitrogen-13. The literature survey of carbon-11, fluorine-18 and nitrogen-13 labeled compounds presented are of particular value to scientists working in this field. Two appendices are also included to provide supplementary general references. A subject index concludes this volume

  9. The influence of nonuniform micro-distribution of alpha emitter on microdosimetry in cells

    International Nuclear Information System (INIS)

    Tian Yuan; Zhang Liang'an; Dai Guangfu

    2007-01-01

    Objective: To study the influence of nonuniform micro-distribution of alpha emitter on cellular S values(in the radioimmunotherapy). Methods: Emission of alpha particles is randomly simulated by Monte Carlo method; the incident energy and exit energy are calculated with interpolation technique based on the relationship between range and energy of alpha particle and the analytical Continuous Slowing Down Approximation (CSDA) model. So energy deposited in the target area can be obtained. To take 213 Po as an example, cellular S values with various cell dimensions and possible micro-distributions of radioactivity are calculated, such as linear increase, linear decrease, exponential increase and exponential decrease. Results: S values from cell to cell of uniform distribution showed no difference with the Hamacher's results. S values of different micro-distributions are distinguishing with each other. It is indicated that different micro-distributions of radioactivity will result in significant change of average chord length of alpha particles traveling in the target area, as well as the change of average stopping power over the chord, which is primary reason for differences of S values. Conclusions: The nonuniform micro-distributions show remarkable influence on cellular S values and hence should be taken consideration in cellular absorbed dose estimation, especially in microdosimetry. (authors)

  10. Alpha-particles induce autophagy in multiple myeloma cells

    Directory of Open Access Journals (Sweden)

    Joelle Marcelle Gaschet

    2015-10-01

    Full Text Available Objectives: Radiations emitted by the radionuclides in radioimmunotherapy (RIT approaches induce direct killing of the targeted cells as well as indirect killing through bystander effect. Our research group is dedicated to the development of α-RIT, i.e RIT using α-particles especially for the treatment of multiple myeloma (MM. γ-irradiation and β-irradiation have been shown to trigger apoptosis in tumor cells. Cell death mode induced by 213Bi α-irradiation appears more controversial. We therefore decided to investigate the effects of 213Bi on MM cell radiobiology, notably cell death mechanisms as well as tumor cell immunogenicity after irradiation.Methods: Murine 5T33 and human LP-1 multiple myeloma (MM cell lines were used to study the effects of such α-particles. We first examined the effects of 213Bi on proliferation rate, double strand DNA breaks, cell cycle and cell death. Then, we investigated autophagy after 213Bi irradiation. Finally, a co-culture of dendritic cells (DC with irradiated tumour cells or their culture media was performed to test whether it would induce DC activation.Results: We showed that 213Bi induces DNA double strand breaks, cell cycle arrest and autophagy in both cell lines but we detected only slight levels of early apoptosis within the 120 hours following irradiation in 5T33 and LP-1. Inhibition of autophagy prevented 213Bi induced inhibition of proliferation in LP-1 suggesting that this mechanism is involved in cell death after irradiation. We then assessed the immunogenicity of irradiated cells and found that irradiated LP-1 can activate DC through the secretion of soluble factor(s, however no increase in membrane or extracellular expression of danger associated molecular patterns (DAMPs was observed after irradiation.Conclusion: This study demonstrates that 213Bi induces mainly necrosis in MM cells, low levels of apoptosis and also autophagy that might be involved in tumor cell death.

  11. Numerical studies of emittance exchange in 2-D charged-particle beams

    International Nuclear Information System (INIS)

    Guy, F.W.

    1986-01-01

    We describe results obtained from a two-dimensional particle-following computer code that simulates a continuous, nonrelativistic, elliptical charged-particle beam with linear continuous focusing. Emittances and focusing strengths can be different in the two transverse directions. The results can be applied, for example, for a quadrupole transport system in a smooth approximation to a real beam with unequal emittances in the two planes. The code was used to study emittance changes caused by kinetic-energy exchange between transverse directions and by shifts in charge distributions. Simulation results for space-charge-dominated beams agree well with analytic formulas. From simulation results, an empirical formula was developed for a ''partition parameter'' (the ratio of kinetic energies in the two directions) as a function of initial conditions and beamline length. Quantitative emittance changes for each transverse direction can be predicted by using this parameter. Simulation results also agree with Hofmann's generalized differential equation relating emittance and field energy

  12. Growth rate of non-thermodynamic emittance of intense electron beams

    International Nuclear Information System (INIS)

    Carlsten, B.E.

    1998-01-01

    The nonlinear free-energy concept has been particularly useful in estimating the emittance growth resulting from any excess energy of electron beams in periodic and uniform channels. However, additional emittance growth, that is geometrical rather than thermodynamic in origin, is induced if the particles have different kinetic energies and axial velocities, which is common for mildly relativistic, very intense electron beams. This effect is especially strong if particles lose or gain significant kinetic energy due to the beam's potential depression, as the beam converges and diverges. In this paper we analyze these geometric emittance growth mechanisms for a uniform, continuous, intense electron beam in a focusing transport channel consisting of discrete solenoidal magnets, over distances short enough that the beam does not reach equilibrium. These emittance growth mechanisms are based on the effects of (1) energy variations leading to nonlinearities in the space-charge force even if the current density is uniform, (2) an axial velocity shear radially along the beam due to the beam's azimuthal motion in the solenoids, and (3) an energy redistribution of the beam as the beam compresses or expands. The geometric emittance growth is compared in magnitude with that resulting from the nonlinear free energy, for the case of a mismatched beam in a uniform channel, and is shown to dominate for certain experimental conditions. Rules for minimizing the emittance along a beamline are outlined. copyright 1998 The American Physical Society

  13. Measurement of the transverse emittance for the NSC Pelletron

    International Nuclear Information System (INIS)

    Rodriques, G.; Mandal, A.; Chopra, S.; Joshi, R.; Datta, S.K.; Roy, A.

    1998-01-01

    The knowledge of the emittance (transverse and longitudinal) of the NSC pelletron is essential for matching the acceptance of the LINAC which is to be installed to augment the pelletron beam energies. The transverse emittance of NSC pelletron has been measured by employing a focussing element and a down-stream beam profile monitor

  14. Low Cost Constant – Head Drip Irrigation Emitter for Climate ...

    African Journals Online (AJOL)

    Low Cost Constant – Head Drip Irrigation Emitter for Climate Change Adaptation in Nigeria: Engineering Design and Calibration. ... The drip system comprises of abarrel, sub-main line, lateral lines, tubes and emitters, it can irrigate140 crop ...

  15. Experimental studies on coherent synchrotron radiation at an emittance exchange beam line

    Science.gov (United States)

    Thangaraj, J. C. T.; Thurman-Keup, R.; Ruan, J.; Johnson, A. S.; Lumpkin, A. H.; Santucci, J.

    2012-11-01

    One of the goals of the Fermilab A0 photoinjector is to investigate experimentally the transverse to longitudinal emittance exchange (EEX) principle. Coherent synchrotron radiation in the emittance exchange line could limit the performance of the emittance exchanger at short bunch lengths. In this paper, we present experimental and simulation studies of the coherent synchrotron radiation (CSR) in the emittance exchange line at the A0 photoinjector. We report on time-resolved CSR studies using a skew-quadrupole technique. We also demonstrate the advantages of running the EEX with an energy-chirped beam.

  16. 18F- and 11C-labelling of quantum dots with n.c.a. [18F]fluoroethyltosylate and [11C]methyliodide. A feasibility study

    International Nuclear Information System (INIS)

    Patt, M.; Schildan, A.; Habermann, B.; Mishchenko, O.; Patt, J.T.; Sabri, O.

    2010-01-01

    Quantum dots functionalized on the outer surface with either amino- or carboxyl functions were labelled with [ 18 F]fluoroethyltosylate and [ 11 C]methyliodide in order to use the positron emitter-labelled fluorescence agents for multimodality imaging techniques, i.e. fluorescence imaging and positron emission tomography. 18 F-Labelling of both compounds was realized with yields up to 5% as determined by size exclusion chromatography, which is twice as much as reported in literature before [1]. 11 C-Labelling of amino- and carboxyl-QDs proceeded with good yields (up to 45 and 35%, respectively) under optimized reaction conditions. In general for both QD-types and both labelling agents the labelling yield increased with the amount of QDs used in the reaction as well as with reaction time and reaction temperature. (author)

  17. Electron field emission characteristics of graphene/carbon nanotubes hybrid field emitter

    International Nuclear Information System (INIS)

    Chen, Leifeng; He, Hong; Yu, Hua; Cao, Yiqi; Lei, Da; Menggen, QiQiGe; Wu, Chaoxing; Hu, Liqin

    2014-01-01

    The graphene (GP) and multi-walled carbon nanotubes (MCNTs) hybrid nanostructure emitter was constructed by a larger scale electrophoretic deposition (EPD) method. The field emission (FE) performance of the hybrid emitter is greatly improved compared with that of only GP or MCNTs emitter. The low turn-on electric field (EF), the low threshold EF and the reliability FE properties are obtained from the hybrid emitter. The better FE properties result from the improved electrical properties. For further enhancement FE of hybrids, Ag Nanoparticles (NPs) were decorated on the hybrids and FE characteristics were also studied. These studies indicate that we can use the hybrid nanostructure to improve conductivity and contact resistance, which results in enhancement of the FE properties

  18. Studies of emittance growth in the ATF

    International Nuclear Information System (INIS)

    Zimmermann, F.

    1997-03-01

    Several different mechanisms of emittance growth in the Accelerator Test Facility (ATF) at KEK are investigated: the author calculates rise times of the fast beam-ion instability for the damping ring (DR), and discusses the emittance growth caused by coherent synchrotron radiation in the beam-transport line (BT), the effect of quadrupole wake fields in the injector linac, and, finally, a single-bunch head-tail ion effect that can occur in both the DR and the BT. A first attempt to measure the quadrupole wake on the real machine is also reported

  19. Chemically doped three-dimensional porous graphene monoliths for high-performance flexible field emitters.

    Science.gov (United States)

    Kim, Ho Young; Jeong, Sooyeon; Jeong, Seung Yol; Baeg, Kang-Jun; Han, Joong Tark; Jeong, Mun Seok; Lee, Geon-Woong; Jeong, Hee Jin

    2015-03-12

    Despite the recent progress in the fabrication of field emitters based on graphene nanosheets, their morphological and electrical properties, which affect their degree of field enhancement as well as the electron tunnelling barrier height, should be controlled to allow for better field-emission properties. Here we report a method that allows the synthesis of graphene-based emitters with a high field-enhancement factor and a low work function. The method involves forming monolithic three-dimensional (3D) graphene structures by freeze-drying of a highly concentrated graphene paste and subsequent work-function engineering by chemical doping. Graphene structures with vertically aligned edges were successfully fabricated by the freeze-drying process. Furthermore, their number density could be controlled by varying the composition of the graphene paste. Al- and Au-doped 3D graphene emitters were fabricated by introducing the corresponding dopant solutions into the graphene sheets. The resulting field-emission characteristics of the resulting emitters are discussed. The synthesized 3D graphene emitters were highly flexible, maintaining their field-emission properties even when bent at large angles. This is attributed to the high crystallinity and emitter density and good chemical stability of the 3D graphene emitters, as well as to the strong interactions between the 3D graphene emitters and the substrate.

  20. Cellular uptake of fluorophore-labeled glyco-DNA–gold nanoparticles

    International Nuclear Information System (INIS)

    Witten, Katrin G.; Ruff, Julie; Mohr, Anne; Görtz, Dieter; Recker, Tobias; Rinis, Natalie; Rech, Claudia; Elling, Lothar; Müller-Newen, Gerhard; Simon, Ulrich

    2013-01-01

    DNA-functionalized gold nanoparticles (AuNP–DNA) were hybridized with complementary di-N-acetyllactosamine-(di-LacNAc, [3Gal(β1-4)GlcNAc(β1-]2)-modified oligonucleotides to form glycol-functionalized particles, AuNP–DNA–di-LacNAc. While AuNP–DNA are known to be taken up by cells via scavenger receptors, glycol-functionalized particles have shown to be taken up via asialoglycoprotein receptors (ASGP-R). In this work, the interaction of these new particles with HepG2 cells was analyzed, which express scavenger receptors class B type I (SR-BI) and ASGP-R. To study the contribution of these receptors as potential mediators for cellular uptake, receptor-blocking experiments were performed with d-lactose, a ligand for ASGP-R, Fucoidan, a putative ligand for SR-BI, and a SR-BI blocking antibody. Labeling with Cy5-modified DNA ligands enabled us to monitor the particle uptake by confocal fluorescence microscopy and flow cytometry, in order to discriminate the two putative pathways by competitive binding studies. While SR-BI-antibody and d-lactose had no inhibiting effects on particle uptake Fucoidan led to a complete inhibition. Thus, a receptor-mediated uptake by the two receptors studied could not be proven and therefore other uptake mechanisms have to be considered

  1. Cellular uptake of fluorophore-labeled glyco-DNA-gold nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Witten, Katrin G.; Ruff, Julie [RWTH Aachen University, Institute of Inorganic Chemistry and JARA - Fundamentals of Future Information Technology (Germany); Mohr, Anne; Goertz, Dieter; Recker, Tobias; Rinis, Natalie [RWTH Aachen University, Institute of Biochemistry and Molecular Biology, University Hospital Aachen (Germany); Rech, Claudia; Elling, Lothar [RWTH Aachen University, Laboratory for Biomaterials, Institute of Biotechnology and Helmholtz-Institute for Biomedical Engineering (Germany); Mueller-Newen, Gerhard [RWTH Aachen University, Institute of Biochemistry and Molecular Biology, University Hospital Aachen (Germany); Simon, Ulrich, E-mail: ulrich.simon@ac.rwth-aachen.de [RWTH Aachen University, Institute of Inorganic Chemistry and JARA - Fundamentals of Future Information Technology (Germany)

    2013-10-15

    DNA-functionalized gold nanoparticles (AuNP-DNA) were hybridized with complementary di-N-acetyllactosamine-(di-LacNAc, [3Gal({beta}1-4)GlcNAc({beta}1-]2)-modified oligonucleotides to form glycol-functionalized particles, AuNP-DNA-di-LacNAc. While AuNP-DNA are known to be taken up by cells via scavenger receptors, glycol-functionalized particles have shown to be taken up via asialoglycoprotein receptors (ASGP-R). In this work, the interaction of these new particles with HepG2 cells was analyzed, which express scavenger receptors class B type I (SR-BI) and ASGP-R. To study the contribution of these receptors as potential mediators for cellular uptake, receptor-blocking experiments were performed with d-lactose, a ligand for ASGP-R, Fucoidan, a putative ligand for SR-BI, and a SR-BI blocking antibody. Labeling with Cy5-modified DNA ligands enabled us to monitor the particle uptake by confocal fluorescence microscopy and flow cytometry, in order to discriminate the two putative pathways by competitive binding studies. While SR-BI-antibody and d-lactose had no inhibiting effects on particle uptake Fucoidan led to a complete inhibition. Thus, a receptor-mediated uptake by the two receptors studied could not be proven and therefore other uptake mechanisms have to be considered.

  2. 22 CFR 213.37 - Referrals to the Department of Justice.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Referrals to the Department of Justice. 213.37... Department of Justice § 213.37 Referrals to the Department of Justice. (a) The CFO, through the FMS cross... of Justice's Nationwide Central Intake Facility as required by the Claims Collection Litigation...

  3. 42 CFR 405.213 - Re-evaluation of a device categorization.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Re-evaluation of a device categorization. 405.213... Decisions That Relate to Health Care Technology § 405.213 Re-evaluation of a device categorization. (a... experimental/investigational (Category A) may request re-evaluation of the categorization decision. (2) A...

  4. Double-step annealing and ambient effects on phosphorus implanted emitters in silicon

    International Nuclear Information System (INIS)

    Koji, T.; Tseng, W.F.; Mayer, J.W.; Suganuma, T.

    1979-01-01

    Emitters of npn silicon bipolar transistors have been made by a phosphorus implantation at 50 keV P + to a dose of 1 x 10 16 cm -2 . This was followed by high temperature processes to reduce lattice disorder, to drive-in the phosphorus atoms, and to form oxide layers. The first process step was carried out by using single- and double-step anneals in various ambients (dry N 2 , dry 0 2 and steam) while the drive-in and oxidation steps were common for all structures. Electrical measurements on emitter/base leakage current, low frequency (popcorn) noise and current gain showed that the annealing ambient had a major influence. The transistors with implanted emitters annealed in a dry N 2 ambient are comparable to commercial ones with thermally-diffused emitters. Transmission electron microscopy observations on samples annealed in steam ambients revealed dislocations extending into the sidewall of the emitter/base junction. This sidewell penetration of dislocations is the main origin of the degradation of the emitter/base junction characteristics. (author)

  5. In-situ synthesis of nanofibers with various ratios of BiOCl{sub x}/BiOBr{sub y}/BiOI{sub z} for effective trichloroethylene photocatalytic degradation

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yifan [Department of Chemistry, Inha University, 100 Inharo, Incheon 402-751 (Korea, Republic of); Park, Mira [Department of Organic Materials and Fiber Engineering, Chonbuk National University, Jeonju 561-756 (Korea, Republic of); Kim, Hak Yong [Department of BIN Convergence Technology, Chonbuk National University, Jeonju, 561-756 (Korea, Republic of); Ding, Bin [College of Textiles, Donghua University, Shanghai 201620 (China); Park, Soo-Jin, E-mail: sjpark@inha.ac.kr [Department of Chemistry, Inha University, 100 Inharo, Incheon 402-751 (Korea, Republic of)

    2016-10-30

    Highlights: • BiOCl{sub x}/BiOBr{sub y}/BiOI{sub z}/PAN fibers were synthesized by in-situ method. • Photodegradation behavior of BiOCl{sub x}/BiOBr{sub y}/BiOI{sub z}/PAN fibers was measured under solar light irradiation. • BiOCl{sub 0.3}/BiOBr{sub 0.3}/BiOI{sub 0.4}/PAN fibers exhibited the highest photocatalytic activity. • Photocatalytic mechanism was discussed in detail. - Abstract: In this work, BiOCl{sub x}/BiOBr{sub y}/BiOI{sub z} (x + y + z = 1) composite nanofibers were prepared through electrospinning and the sol-gel methods. Photocatalytic degradation of trichloroethylene (TCE) by BiOCl{sub x}/BiOBr{sub y}/BiOI{sub z}/PAN nanofibers was systematically investigated via gas chromatography (GC). Optimum photocatalytic activity was achieved with BiOCl{sub 0.3}/BiOBr{sub 0.3}/BiOI{sub 0.4} fibers under solar light irradiation. X-ray photoelectron spectroscopy (XPS) peaks due to C−O and C=O were observed at 286.0 and 288.3 eV, respectively, it indicated that the BiOCl{sub x}/BiOBr{sub y}/BiOI{sub z} mixture had been successfully doped on the polyacrylonitrile (PAN) fibers. Furthermore, X-ray diffraction (XRD) results also confirmed that we had synthesized the as-prepared composite nanofibers successfully. Photocatalytic activities of BiOCl{sub 0.3}/BiOBr{sub 0.3}/BiOI{sub 0.4} were up to 3 times higher than the pure BiOCl, BiOBr and BiOI samples, respectively.

  6. Emittance growth in the DARHT Axis-II Downstream Transport

    Energy Technology Data Exchange (ETDEWEB)

    Ekdahl, Jr., Carl August [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Schulze, Martin E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-04-14

    Using a particle-in-cell (PIC) code, we investigated the possibilities for emittance growth through the quadrupole magnets of the system used to transport the high-current electron beam from an induction accelerator to the bremsstrahlung converter target used for flash radiography. We found that even highly mismatched beams exhibited little emittance growth (< 6%), which we attribute to softening of their initial hard edge current distributions. We also used this PIC code to evaluate the accuracy of emittance measurements using a solenoid focal scan following the quadrupole magnets. If the beam is round after the solenoids, the simulations indicate that the measurement is highly accurate, but it is substantially inaccurate for elliptical beams

  7. Field emission from optimized structure of carbon nanotube field emitter array

    International Nuclear Information System (INIS)

    Chouhan, V.; Noguchi, T.; Kato, S.

    2016-01-01

    The authors report a detail study on the emission properties of field emitter array (FEA) of micro-circular emitters of multiwall carbon nanotubes (CNTs). The FEAs were fabricated on patterned substrates prepared with an array of circular titanium (Ti) islands on titanium nitride coated tantalum substrates. CNTs were rooted into these Ti islands to prepare an array of circular emitters. The circular emitters were prepared in different diameters and pitches in order to optimize their structure for acquiring a high emission current. The pitch was varied from 0 to 600 μm, while a diameter of circular emitters was kept constant to be 50 μm in order to optimize a pitch. For diameter optimization, a diameter was changed from 50 to 200 μm while keeping a constant edge-to-edge distance of 150 μm between the circular emitters. The FEA with a diameter of 50 μm and a pitch of 120 μm was found to be the best to achieve an emission current of 47 mA corresponding to an effective current density of 30.5 A/cm"2 at 7 V/μm. The excellent emission current was attributed to good quality of CNT rooting into the substrate and optimized FEA structure, which provided a high electric field on a whole circular emitter of 50 μm and the best combination of the strong edge effect and CNT coverage. The experimental results were confirmed with computer simulation.

  8. Field emission from optimized structure of carbon nanotube field emitter array

    Energy Technology Data Exchange (ETDEWEB)

    Chouhan, V., E-mail: vchouhan@post.kek.jp, E-mail: vijaychouhan84@gmail.com [School of High Energy Accelerator, The Graduate University for Advanced Studies, Tsukuba 305-0801 (Japan); Noguchi, T. [High Energy Accelerator Research Organization (KEK), Tsukuba 305-0801 (Japan); Kato, S. [School of High Energy Accelerator, The Graduate University for Advanced Studies, Tsukuba 305-0801 (Japan); High Energy Accelerator Research Organization (KEK), Tsukuba 305-0801 (Japan)

    2016-04-07

    The authors report a detail study on the emission properties of field emitter array (FEA) of micro-circular emitters of multiwall carbon nanotubes (CNTs). The FEAs were fabricated on patterned substrates prepared with an array of circular titanium (Ti) islands on titanium nitride coated tantalum substrates. CNTs were rooted into these Ti islands to prepare an array of circular emitters. The circular emitters were prepared in different diameters and pitches in order to optimize their structure for acquiring a high emission current. The pitch was varied from 0 to 600 μm, while a diameter of circular emitters was kept constant to be 50 μm in order to optimize a pitch. For diameter optimization, a diameter was changed from 50 to 200 μm while keeping a constant edge-to-edge distance of 150 μm between the circular emitters. The FEA with a diameter of 50 μm and a pitch of 120 μm was found to be the best to achieve an emission current of 47 mA corresponding to an effective current density of 30.5 A/cm{sup 2} at 7 V/μm. The excellent emission current was attributed to good quality of CNT rooting into the substrate and optimized FEA structure, which provided a high electric field on a whole circular emitter of 50 μm and the best combination of the strong edge effect and CNT coverage. The experimental results were confirmed with computer simulation.

  9. 49 CFR 213.317 - Waivers.

    Science.gov (United States)

    2010-10-01

    ... TRANSPORTATION TRACK SAFETY STANDARDS Train Operations at Track Classes 6 and Higher § 213.317 Waivers. (a) Any... railroad safety, the Administrator may grant the waiver subject to any conditions the Administrator deems necessary. Where a waiver is granted, the Administrator publishes a notice containing the reasons for...

  10. 49 CFR 234.213 - Grounds.

    Science.gov (United States)

    2010-10-01

    ... Maintenance Standards § 234.213 Grounds. Each circuit that affects the proper functioning of a highway-rail... in the circuit. This requirement does not apply to: circuits that include track rail; alternating current power distribution circuits that are grounded in the interest of safety; and common return wires...

  11. Calculating emittance for Gaussian and Non-Gaussian distributions by the method of correlations for slits

    International Nuclear Information System (INIS)

    Tan, Cheng-Yang; Fermilab

    2006-01-01

    One common way for measuring the emittance of an electron beam is with the slits method. The usual approach for analyzing the data is to calculate an emittance that is a subset of the parent emittance. This paper shows an alternative way by using the method of correlations which ties the parameters derived from the beamlets to the actual parameters of the parent emittance. For parent distributions that are Gaussian, this method yields exact results. For non-Gaussian beam distributions, this method yields an effective emittance that can serve as a yardstick for emittance comparisons

  12. Fabrication of multi-emitter array of CNT for enhancement of current density

    Energy Technology Data Exchange (ETDEWEB)

    Chouhan, Vijay, E-mail: vchouhan@post.kek.jp [Department of Accelerator Science, Graduate University for Advanced Studies, 1-1 Oho, Tsukuba, Ibaraki (Japan); Noguchi, Tsuneyuki [High Energy Accelerator Research Organization-KEK, 1-1 Oho, Tsukuba, Ibaraki (Japan); Kato, Shigeki [Department of Accelerator Science, Graduate University for Advanced Studies, 1-1 Oho, Tsukuba, Ibaraki (Japan); High Energy Accelerator Research Organization-KEK, 1-1 Oho, Tsukuba, Ibaraki (Japan)

    2011-11-11

    We studied and compared field emission properties of two kinds of emitters of randomly oriented multi-wall carbon nanotubes (MWNTs), viz. continuous film emitter (CFE) and multi-emitter array (MEA). The CFE has a continuous film of MWNTs while the MEA consists of many equidistant small circular emitters. Both types of emitters were prepared by dispersing MWNTs over a titanium (Ti) film (for CFEs) or Ti circular islands (for MEAs) deposited on tantalum (Ta) followed by rooting of MWNTs into the Ti film or the Ti islands at high temperature. Emission properties of both types of emitters were analyzed with changing their emission areas. In case of the CFEs, current density decreased with an increase in emission area whereas consistent current densities were achieved from MEAs with different emission areas. In other words, the total emission current was achieved in proportion to the emission area in the case of MEAs. Additionally a high current density of 22 A/cm{sup 2} was achieved at an electric field of 8 V/{mu}m from MEAs, which was far better than that obtained from CFEs. The high current density in MEAs was attributed to edge effect, in which higher emission current is achieved from the edge of film emitter. The results indicate that the field emission characteristics can be greatly improved if a cathode contains many small equidistant circular emitters instead of a continuous film. The outstanding stability of the CFE and the MEA has been demonstrated for 2100 and 1007 h, respectively.

  13. Emittance growth due to negative-mass instability above transition

    International Nuclear Information System (INIS)

    Ng, King-Yuen.

    1994-08-01

    Due to space-charge effect, there is a growth of bunch emittance across transition as a result of negative-mass instability. The models of growth at cutoff frequency and growth from high-frequency Schottky noise are reviewed. The difficulties of performing reliable simulations are discussed. An intuitive self-bunching model for estimating emittance growth is presented

  14. Experimental studies on coherent synchrotron radiation at an emittance exchange beam line

    Directory of Open Access Journals (Sweden)

    J. C. T. Thangaraj

    2012-11-01

    Full Text Available One of the goals of the Fermilab A0 photoinjector is to investigate experimentally the transverse to longitudinal emittance exchange (EEX principle. Coherent synchrotron radiation in the emittance exchange line could limit the performance of the emittance exchanger at short bunch lengths. In this paper, we present experimental and simulation studies of the coherent synchrotron radiation (CSR in the emittance exchange line at the A0 photoinjector. We report on time-resolved CSR studies using a skew-quadrupole technique. We also demonstrate the advantages of running the EEX with an energy-chirped beam.

  15. Analysis of emittance compensation and simulation results to photo-cathode RF gun

    CERN Document Server

    LiuShengGuang

    2002-01-01

    The emittance compensation technology will be used on the photo-cathode RF gun for Shanghai SDUV-FEL. The space charge force and its effect on electron beam transverse emittance in RF gun is studied, the principle of emittance compensation in phase-space is discussed. The authors have designed a compensation solenoid and calculated its magnetic field distribution. Its performance has been studied by the code PARMELA. A simulation result indicates that the normalized transverse RMS emittance for electron beam of 1.5 nC is 1.612 pi mm centre dot mrad, electron energy E = 5.71 MeV

  16. Very low recombination phosphorus emitters for high efficiency crystalline silicon solar cells

    International Nuclear Information System (INIS)

    Ortega, P; Vetter, M; Bermejo, S; Alcubilla, R

    2008-01-01

    This work studies low recombination phosphorus emitters on c-Si. The emitters are fabricated by diffusion from solid sources and then passivated by thermal oxide yielding sheet resistances between 15 and 280 Ω/sq. Emitter saturation current densities lie in the 2.5–110 fA cm −2 range, leading to implicit open-circuit voltages between 674 and 725 mV. Bulk lifetime is limited by intrinsic recombination mechanisms. Surface recombination velocities between 80 and 300 cm s −1 have been obtained, appearing among the lowest reported in this range of emitter sheet resistances

  17. Facile Fabrication of BiOI/BiOCl Immobilized Films With Improved Visible Light Photocatalytic Performance

    Directory of Open Access Journals (Sweden)

    Yingxian Zhong

    2018-03-01

    Full Text Available HIGHLIGHTSA facial method was used to fabricate BiOI/BiOCl film at room temperature.30% BiOI/BiOCl showed an excellent photocatalytic activity and stability.Improvement of photocatalytic activity was owed to expanded visible light absorption and high separation efficiency of charge.Photocatalysis has been considered to be one of the most promising ways to photodegrade organic pollutants. Herein, a series of BiOI/BiOCl films coating on FTO were fabricated through a simple method at room temperature. The photocatalytic efficiency of 30%BiOI/BiOCl could reach more than 99% aiming to degrading RhB and MB after 90 and 120 min, respectively. Compared with BiOCl, 30%BiOI/BiOCl showed 12 times higher efficiency when degrading RhB. In comparison with BiOI, 30%BiOI/BiOCl showed 5 and 6 times higher efficiency when degrading RhB and MB, respectively. These obvious enhancements were attributed to expanded visible light absorption and high separation performance of photoinduced charge. Moreover, the photocatalytic activity of 30%BiOI/BiOCl had no obvious decrease after five recycles, suggesting that it was a promising photocatalyst for the removal of MB and RhB pollutants. Finally, the possible growth process for the BiOI/BiOCl thin films and photocatalysis mechanism were investigated in details. This work would provide insight to the reasonable construction of BiOX heterojunction and the photocatalytic mechanism in degrading organic pollutants.

  18. Influence of photoinduced Bi-related self-doping on the photocatalytic activity of BiOBr nanosheets

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Dan [School of Life Sciences, The Chinese University of Hong Kong, Shatin, NT, Hong Kong SAR (China); Yue, Songtao; Wang, Wei [College of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); An, Tiacheng, E-mail: antc99@gig.ac.cn [Institute of Environmental Health and Pollution Control, School of Environmental Science and Engineering, Guangdong University of Technology, Guangzhou 510006 (China); Li, Guiying [Institute of Environmental Health and Pollution Control, School of Environmental Science and Engineering, Guangdong University of Technology, Guangzhou 510006 (China); Ye, Liqun [School of Life Sciences, The Chinese University of Hong Kong, Shatin, NT, Hong Kong SAR (China); College of Chemistry and Pharmaceutical Engineering, Nanyang Normal University, Nanyang 473061 (China); Yip, Ho Yin [School of Life Sciences, The Chinese University of Hong Kong, Shatin, NT, Hong Kong SAR (China); Wong, Po Keung, E-mail: pkwong@cuhk.edu.hk [School of Life Sciences, The Chinese University of Hong Kong, Shatin, NT, Hong Kong SAR (China)

    2017-01-01

    Highlights: • Bi{sup 5+} self-doped BiOBr nanosheets are achieved under UV irradiation. • Bi{sup 5+} is formed due to the oxidation of surface Bi{sup 3+} by photoexcited h{sup +} of BiOBr. • Two photoinduced h{sup +} mediated oxidation processes happen simultaneously. • Self-doped BiOBr is superior in phenol degradation and bacterial inactivation. • Bi{sup 5+} electron trapping induced photocatalytic enhancement mechanism is proposed. - Abstract: Under UV irradiation, self-doped Bi{sup 5+} is evidenced to be generated on the surface of BiOBr nanosheets, but with well-preserved crystal structure and morphology compared with pure counterpart. Bi{sup 5+} self-doping BiOBr (BiOBr-4) exhibits distinct photocatalytic mode for dyes degradation, as compared with pure BiOBr nanosheets. These photodegradation distinctions are mainly due to the simultaneous occurrence of two photoinduced hole (h{sup +}) mediated oxidation processes on the BiOBr surfaces: (1) a portion of photoexcited h{sup +} participates in the photocatalytic oxidation of dyes, and (2) partial h{sup +} involves the oxidation of Bi{sup 3+} to Bi{sup 5+}. Notably, BiOBr-4 nanosheets comparatively show superior photocatalytic activity for the phenol decomposition as well as the bacterial inactivation. Besides Bi{sup 5+} induced narrowed bandgap and enhanced light adsorption capacity, significantly, the oxidative Bi{sup 5+} acts as electron traps to promote the photoexcited electron-hole separation and accelerate h{sup +} migration, resulting in the considerable photocatalytic enhancement of BiOBr-4 nanosheets. These novel findings will not only give new insights into the photocatalytic mechanism but also explore new route to enhance photocatalytic performance of Bi-based materials.

  19. Origins of transverse emittance blow-up during the LHC energy tramp

    CERN Document Server

    Kuhn, M; Arduini, G; Kain, V; Schaumann, M; Tomas, R

    2014-01-01

    During LHC Run 1 about 30 % of the potential peak performance was lost due to transverse emittance blow-up through the LHC cycle. Measurements indicated that the majority of the blow-up occurred during the energy ramp. Until the end of LHC Run 1 this emittance blow-up could not be eliminated. In this paper the measurements and observations of emittance growth through the ramp are summarized. Simulation results for growth due to Intra Beam Scattering will be shown and compared to measurements. A summary of investigations of other possible sources will be given and backed up with simulations where possible. Requirements for commissioning the LHC with beam in 2015 after Long Shutdown 1 to understand and control emittance blow-up will be listed.

  20. 166Ho and 90Y labeled 6D2 monoclonal antibody for targeted radiotherapy of melanoma: Comparison with 188Re radiolabel

    International Nuclear Information System (INIS)

    Thompson, S.; Ballard, B.; Jiang, Z.; Revskaya, E.; Sisay, N.; Miller, W.H.; Cutler, C.S.; Dadachova, E.; Francesconi, L.C.

    2014-01-01

    Introduction: An approach to radioimmunotherapy (RIT) of metastatic melanoma is the targeting of melanin pigment with monoclonal antibodies (mAbs) to melanin radiolabeled with therapeutic radionuclides. The proof of principle experiments were performed using a melanin-binding antibody 6D2 of IgM isotype radiolabeled with a β emitter 188 Re and demonstrated the inhibition of tumor growth. In this study we investigated the efficacy of 6D2 antibody radiolabeled with two other longer lived β emitters 90 Y and 166 Ho in treatment of experimental melanoma, with the objective to find a possible correlation between the efficacy and half-life of the radioisotopes which possess high energy β (E max > 1.5 MeV) emission properties. Methods: 6D2 was radiolabeled with longer lived β emitters 90 Y and 166 Ho in treatment of experimental melanoma in A2058 melanoma tumor-bearing nude mice. The immunoreactivity of the radiolabeled 6D2 mAb, its in vitro binding to the MNT1 human melanoma cells, the biodistribution and therapy in A2058 human melanoma bearing nude mice as well as dosimetry calculations were performed. Results: When labeled with the longer lived 90 Y radionuclide, the 6D2 mAb did not produce any therapeutic effect in tumor bearing mice while the reduction of the tumor growth by 166 Ho-6D2 was very similar to the previously reported therapy results for 188 Re-6D2. In addition, 166 Ho-labeled mAb produced the therapeutic effect on the tumor without any toxic effects while the administration of the 90 Y-labeled radioconjugate was toxic to mice with no appreciable anti-tumor effect. Conclusions: 166 Ho-labeled mAb to melanin produced some therapeutic effect on the tumor without any toxic effects while the administration of the 90 Y-labeled radioconjugate was toxic to mice with no appreciable anti-tumor effect. We concluded that the serum half-life of the 6D2 carrier antibody matched well the physical half-life of 166 Ho to deliver the tumoricidal absorbed dose to the

  1. Schottky’s conjecture, field emitters, and the point charge model

    Directory of Open Access Journals (Sweden)

    Kevin L. Jensen

    2016-06-01

    Full Text Available A Point Charge Model of conical field emitters, in which the emitter is defined by an equipotential surface of judiciously placed charges over a planar conductor, is used to confirm Schottky’s conjecture that field enhancement factors are multiplicative for a small protrusion placed on top of a larger base structure. Importantly, it is shown that Schottky’s conjecture for conical / ellipsoidal field emitters remains unexpectedly valid even when the dimensions of the protrusion begin to approach the dimensions of the base structure. The model is analytic and therefore the methodology is extensible to other configurations.

  2. Positioning with stationary emitters in a two-dimensional space-time

    International Nuclear Information System (INIS)

    Coll, Bartolome; Ferrando, Joan Josep; Morales, Juan Antonio

    2006-01-01

    The basic elements of the relativistic positioning systems in a two-dimensional space-time have been introduced in a previous work [Phys. Rev. D 73, 084017 (2006)] where geodesic positioning systems, constituted by two geodesic emitters, have been considered in a flat space-time. Here, we want to show in what precise senses positioning systems allow to make relativistic gravimetry. For this purpose, we consider stationary positioning systems, constituted by two uniformly accelerated emitters separated by a constant distance, in two different situations: absence of gravitational field (Minkowski plane) and presence of a gravitational mass (Schwarzschild plane). The physical coordinate system constituted by the electromagnetic signals broadcasting the proper time of the emitters are the so called emission coordinates, and we show that, in such emission coordinates, the trajectories of the emitters in both situations, the absence and presence of a gravitational field, are identical. The interesting point is that, in spite of this fact, particular additional information on the system or on the user allows us not only to distinguish both space-times, but also to complete the dynamical description of emitters and user and even to measure the mass of the gravitational field. The precise information under which these dynamical and gravimetric results may be obtained is carefully pointed out

  3. Drifts in ADCC-related quality attributes of Herceptin®: Impact on development of a trastuzumab biosimilar.

    Science.gov (United States)

    Kim, Seokkyun; Song, Jinsu; Park, Seungkyu; Ham, Sunyoung; Paek, Kyungyeol; Kang, Minjung; Chae, Yunjung; Seo, Heewon; Kim, Hyung-Chan; Flores, Michael

    A biosimilar product needs to demonstrate biosimilarity to the originator reference product, and the quality profile of the latter should be monitored throughout the period of the biosimilar's development to match the quality attributes of the 2 products that relate to efficacy and safety. For the development of a biosimilar version of trastuzumab, the reference product, Herceptin®, was extensively characterized for the main physicochemical and biologic properties by standard or state-of-the-art analytical methods, using multiple lots expiring between March 2015 and December 2019. For lots with expiry dates up to July 2018, a high degree of consistency was observed for all the tested properties. However, among the lots expiring in August 2018 or later, a downward drift was observed in %afucose (G0+G1+G2). Furthermore, the upward drift of %high mannose (M5+M6) was observed in the lots with expiry dates from June 2019 to December 2019. As a result, the combination of %afucose and %high mannose showed 2 marked drifts in the lots with expiry dates from August 2018 to December 2019, which was supported by the similar trend of biologic data, such as FcγRIIIa binding and antibody-dependent cell-mediated cytotoxicity (ADCC) activity. Considering that ADCC is one of the clinically relevant mechanisms of action for trastuzumab, the levels of %afucose and %high mannose should be tightly monitored as critical quality attributes for biosimilar development of trastuzumab.

  4. Bi3+–Pr3+ energy transfer processes and luminescent properties of LuAG:Bi,Pr and YAG:Bi,Pr single crystalline films

    International Nuclear Information System (INIS)

    Zorenko, Y.; Gorbenko, V.; Savchyn, V.; Zorenko, T.; Nikl, M.; Mares, J.A.; Beitlerova, A.; Jary, V.

    2013-01-01

    Absorption, cathodoluminescence, excitation spectra of photoluminescence (PL) and PL decay kinetics were studied at 300 K for the double doped with Bi 3+ –Pr 3+ and separately doped with Bi 3+ and Pr 3+ Lu 3 Al 5 O 12 (LuAG) and Y 3 Al 5 O 12 (YAG) single crystalline film (SCF) phosphors grown by the liquid phase epitaxy method. The emission bands in the UV range arising from the intrinsic radiative transitions of Bi 3+ based centers, and emission bands in the visible range, related to the luminescence of excitons localized around Bi 3+ based centers, were identified both in Bi–Pr and Bi-doped LuAG and YAG SCFs. The energy transfer processes from the host lattice simultaneously to Bi 3+ and Pr 3+ ions and from Bi 3+ to Pr 3+ ions were investigated. Competition between Pr 3+ and Bi 3+ ions in the energy transfer processes from the LuAG and YAG hosts was evidenced. The strong decrease of the intensity of Pr 3+ luminescence both in LuAG:Pr and YAG:Pr SCFs phosphors, grown from Bi 2 O 3 flux, is observed due to the quenching influence of Bi 3+ flux related impurity. Due to overlap of the UV emission band of Bi 3+ centers with the f–d absorption bands of Pr 3+ ions in the UV range and the luminescence of excitons localized around Bi ions with the f–f absorption bands of Pr 3+ ions in the visible range, an effective energy transfer from Bi 3+ ions to Pr 3+ ions takes place in LuAG:Bi,Pr and YAG:Bi,Pr SCFs, resulting in the appearance of slower component in the decay kinetics of the Pr 3+ d–f luminescence. -- Highlights: • Bi and Pr doped film phosphor grown by liquid phase epitaxy method. • Energy transfer from Bi 3+ to Pr 3+ ions. • Strong quenching of the Pr 3+ luminescence by Bi 3+ co-dopant

  5. Facile Fabrication of BiOI/BiOCl Immobilized Films with Improved Visible Light Photocatalytic Performance

    Science.gov (United States)

    Zhong, Yingxian; Liu, Yuehua; Wu, Shuang; Zhu, Yi; Chen, Hongbin; Yu, Xiang; Zhang, Yuanming

    2018-03-01

    Photocatalysis has been considered to be one of the most promising ways to photodegrade organic pollutants. Herein, a series of BiOI/BiOCl films coating on FTO were fabricated through a simple method at room temperature. The photocatalytic efficiency of 30%BiOI/BiOCl could reach more than 99% aiming to degrading RhB and MB after 90 and 120 min, respectively. Compared with BiOCl, 30%BiOI/BiOCl showed 12 times higher efficiency when degrading RhB. In comparison with BiOI, 30%BiOI/BiOCl showed 5 and 6 times higher efficiency when degrading RhB and MB, respectively. These obvious enhancements were attributed to expanded visible light absorption and high separation performance of photoinduced charge. Moreover, the photocatalytic activity of 30%BiOI/BiOCl had no obvious decrease after 5 recycles, suggesting that it was a promising photocatalyst for the removal of MB and RhB pollutants. Finally, the possible growth process for the BiOI/BiOCl thin films and photocatalysis mechanism were investigated in details. This work would provide insight to the reasonable construction of BiOX heterojunction and the photocatalytic mechanism in degrading organic pollutants.

  6. Fluorine-18-labelled molecules: synthesis and application in medical imaging

    International Nuclear Information System (INIS)

    Dolle, F.; Perrio, C.; Barre, L.; Lasne, M.C.; Le Bars, D.

    2006-01-01

    Positron emission tomography (PET) is one of the more powerful available techniques for medical imaging. It relies on the use of molecules labelled with a positron emitter (β + ). Among those emitters, fluorine-18, available from a cyclotron, is a radionuclide of choice because of its relatively long-half-life (109.8 min) and the relatively low energy of the emitted-positron. The electrophilic form of fluorine-18 ([ 18 F]F 2 or reagents derived from [ 18 F]F 2 ) is mainly used for hydrogen or metal substitutions on aromatic or vinylic carbons. The presence of the stable isotope (fluorine-19) in the radiotracers limits their use in medical imaging. The nucleophilic form of fluorine-18 (alkaline mono-fluoride, K[ 18 F]F, the most used), obtained from irradiation of enriched water, is widely used in aliphatic and (hetero)aromatic substitutions for the synthesis of radiotracers with high specific radioactivity. Some examples of radio-fluorinated tracers used in PET are presented, as well as some of their in vivo applications in human. (authors)

  7. Laser Process for Selective Emitter Silicon Solar Cells

    Directory of Open Access Journals (Sweden)

    G. Poulain

    2012-01-01

    Full Text Available Selective emitter solar cells can provide a significant increase in conversion efficiency. However current approaches need many technological steps and alignment procedures. This paper reports on a preliminary attempt to reduce the number of processing steps and therefore the cost of selective emitter cells. In the developed procedure, a phosphorous glass covered with silicon nitride acts as the doping source. A laser is used to open locally the antireflection coating and at the same time achieve local phosphorus diffusion. In this process the standard chemical etching of the phosphorous glass is avoided. Sheet resistance variation from 100 Ω/sq to 40 Ω/sq is demonstrated with a nanosecond UV laser. Numerical simulation of the laser-matter interaction is discussed to understand the dopant diffusion efficiency. Preliminary solar cells results show a 0.5% improvement compared with a homogeneous emitter structure.

  8. Accurate estimation of the RMS emittance from single current amplifier data

    International Nuclear Information System (INIS)

    Stockli, Martin P.; Welton, R.F.; Keller, R.; Letchford, A.P.; Thomae, R.W.; Thomason, J.W.G.

    2002-01-01

    This paper presents the SCUBEEx rms emittance analysis, a self-consistent, unbiased elliptical exclusion method, which combines traditional data-reduction methods with statistical methods to obtain accurate estimates for the rms emittance. Rather than considering individual data, the method tracks the average current density outside a well-selected, variable boundary to separate the measured beam halo from the background. The average outside current density is assumed to be part of a uniform background and not part of the particle beam. Therefore the average outside current is subtracted from the data before evaluating the rms emittance within the boundary. As the boundary area is increased, the average outside current and the inside rms emittance form plateaus when all data containing part of the particle beam are inside the boundary. These plateaus mark the smallest acceptable exclusion boundary and provide unbiased estimates for the average background and the rms emittance. Small, trendless variations within the plateaus allow for determining the uncertainties of the estimates caused by variations of the measured background outside the smallest acceptable exclusion boundary. The robustness of the method is established with complementary variations of the exclusion boundary. This paper presents a detailed comparison between traditional data reduction methods and SCUBEEx by analyzing two complementary sets of emittance data obtained with a Lawrence Berkeley National Laboratory and an ISIS H - ion source

  9. Modulation characteristics of graphene-based thermal emitters

    Science.gov (United States)

    Mahlmeister, Nathan Howard; Lawton, Lorreta Maria; Luxmoore, Isaac John; Nash, Geoffrey Richard

    2016-01-01

    We have investigated the modulation characteristics of the emission from a graphene-based thermal emitter both experimentally and through simulations using finite element method modelling. Measurements were performed on devices containing square multilayer graphene emitting areas, with the devices driven by a pulsed DC drive current over a range of frequencies. Simulations show that the dominant heat path is from the emitter to the underlying substrate, and that the thermal resistance between the graphene and the substrate determines the modulation characteristics. This is confirmed by measurements made on devices in which the emitting area is encapsulated by hexagonal boron nitride.

  10. 49 CFR 213.307 - Class of track: operating speed limits.

    Science.gov (United States)

    2010-10-01

    ... requirements for its intended class, it is to be reclassified to the next lower class of track for which it... 49 Transportation 4 2010-10-01 2010-10-01 false Class of track: operating speed limits. 213.307... Higher § 213.307 Class of track: operating speed limits. (a) Except as provided in paragraph (b) of this...

  11. On the electronic structure and thermoelectric properties of BiTeBr and BiTeI single crystals and of BiTeI with the addition of BiI3 and CuI

    International Nuclear Information System (INIS)

    Kulbachinskii, Vladimir A.; Kytin, Vladimir G.; Kudryashov, Alexey A.; Kuznetsov, Alexei N.; Shevelkov, Andrei V.

    2012-01-01

    The electronic structures were calculated for BiTeBr and BiTeI using the density-functional theory approach and accounting for the strong spin–orbital interaction. Qualitatively, the band structures for two compounds are similar, showing strong mixing of the p states of all elements in vicinity of the Fermi level, with the band gaps of 0.595 and 0.478 eV for BiTeBr and BiTeI, respectively. The optimized crystal structures show a tendency for the Bi–X (X=Br, I) bond elongation compared to the Bi–Te one. Both compounds are intrinsic n-type semiconductors but display a metallic-like conductivity coupled to rather large thermopower, which is rationalized within the frames of the acoustic phonons scattering model. Because of larger thermopower BiTeBr exhibits a twice higher thermoelectric figure-of-merit near room temperature, ZT=0.17, compared to BiTeI. The addition of 1 mass% of BiI 3 or CuI to BiTeI decreases the mobility of electrons by two orders of magnitude, leading to significantly lower electrical conductivity, but at the same time effectively reduces the thermal conductivity. The prospects of further enhancing the thermoelectric efficiency are briefly discussed. - Graphical abstract: View of the crystal structure of BiTeBr is shown in the figure The optimized crystal structures show a tendency for the Bi–X (X=Br, I) bond elongation compared to the Bi–Te one. The electronic structures were calculated for BiTeBr and BiTeI using the density-functional theory approach and accounting for the strong spin–orbital interaction. Qualitatively, the band structures for two compounds are similar, showing strong mixing of the p states of all elements in vicinity of the Fermi level, with the band gaps of 0.595 and 0.478 eV for BiTeBr and BiTeI, respectively. Both compounds are intrinsic n-type semiconductors but display a metallic-like conductivity coupled to rather large thermopower, which is rationalized within the frames of the acoustic phonons scattering

  12. The synthesis of [2-13C]2-nitropropane at room temperature and at atmospheric pressure

    OpenAIRE

    Jacquemijns M; Zomer G

    1990-01-01

    In this report the synthesis of [2-13C]2-nitropropane at room temperature is described. [2-13C]Acetone was converted into the oxime with hydroxy hydrochloridelamine and sodium carbonate. Treatment with hypobromic acid resulted in 2-13C]2-bromo-2-nitropropane. Hydrogenation with sodium borohydride gave [2-13C]2-nitropropane in 14,3% overall yield.

  13. Relation between field energy and RMS emittance in intense particle beams

    International Nuclear Information System (INIS)

    Wangler, T.P.; Crandall, K.R.; Mills, R.S.; Reiser, M.

    1985-01-01

    An equation is presented for continuous beams with azimuthal symmetry and continuous linear focusing, which expresses a relationship between the rate of change for squared rms emittance and the rate of change for a quantity we call the nonlinear field energy. The nonlinear field energy depends on the shape of the charge distribution and corresponds to the residual field energy possessed by beams with nonuniform charge distributions. The equation can be integrated for the case of an rms matched beam to yield a formula for space-charge-induced emittance growth that we have tested numerically for a variety of initial distributions. The results provide a framework for discussing the scaling of rms emittance growth and an explanation for the well-established lower limit on output emittance. 15 refs., 4 figs

  14. Beam emittance of the Stony Brook Tandem-LINAC booster

    International Nuclear Information System (INIS)

    Scholldorf, A.H.

    1984-01-01

    This dissertation is primarily a study of the longitudinal and transverse beam emittance of the Stony Brook Heavy Ion Tandem LINAC Accelerator Facility, with a secondary emphasis on the beam dynamical design of two key elements of the system: a low energy double-drift buncher, and an achromatic double-90 0 LINAC injection system. A transverse emittance measuring system consisting of two translation stages controlled by stepper motors is described. Each stage carried a pair of beam defining slits mounted so that both horizontal and vertical emittances could be measured with only linear motion of the stage assembly. Beam currents were measured directly by a low-noise, high-sensitivity electrometer circuit integrated with the second slit-stage assembly. A mini-computer controlled the motors and acquired and displayed the data. Transverse emittance areas of beams of 12 C, 16 O, 32 S, and 58 Ni were measured at ion source extraction potential, after ion source acceleration, after tandem acceleration, and after LINAC acceleration. The results were analyzed in terms of source sputter-cone geometry, angle straggling in gas and foil strippers, and a variety of other factors

  15. Comparison between arc drops in ignited thermionic converters with and without ion reflections at the emitter

    International Nuclear Information System (INIS)

    Lundgren, L.

    1985-01-01

    The output performance of two thermionic energy converters is compared. One converter has a normal emitter, working with zero field at the emitter which is close to the optimum working point, and the other has a low work function emitter and ion reflection at the emitter. A simple model of the plasma and the sheaths shows that a converter working with a low work function emitter and ion reflections gives a worse performance than a similar converter with a normal emitter

  16. Radiolabeling of DOTATOC with the long-lived positron emitter {sup 44}Sc

    Energy Technology Data Exchange (ETDEWEB)

    Pruszynski, Marek; Majkowska-Pilip, Agnieszka [Centre of Radiochemistry and Nuclear Chemistry, Institute of Nuclear Chemistry and Technology, Dorodna 16, 03-195 Warszawa (Poland); Loktionova, Natalia S.; Eppard, Elisabeth [Institute of Nuclear Chemistry, Johannes Gutenberg-University of Mainz, Fritz-Strassmann-Weg 2, D-55128 Mainz (Germany); Roesch, Frank, E-mail: frank.roesch@uni-mainz.de [Institute of Nuclear Chemistry, Johannes Gutenberg-University of Mainz, Fritz-Strassmann-Weg 2, D-55128 Mainz (Germany)

    2012-06-15

    The positron-emitting radionuclide {sup 44}Sc with a half-life of 3.97 h and a {beta}{sup +} branching of 94.3% is of potential interest for clinical PET. As so far it is available from a {sup 44}Ti/{sup 44}Sc generator in Mainz, where long-lived {sup 44}Ti decays to no-carrier-added (nca) {sup 44}Sc. The {sup 44}Sc is a trivalent metal cation and should be suitable for complexation with many well established bifunctional chelators conjugated to peptides or other molecular targeting vectors. Thus, the aim of this work was to investigate the potential of {sup 44}Sc for labeling of DOTA-conjugated peptides. DOTA-D-Phe{sup 1}-Tyr{sup 3}-octreotide (DOTATOC) was used as a model molecule to study and optimize labeling procedure. Reaction parameters such as buffer conditions, concentration of peptide, pH range, reaction temperature and time were optimized. Addition of 21 nmol of DOTATOC to {sup 44}Sc in ammonium acetate buffer pH 4.0 provided labeling yields >98% within 25 min of heating in an oil-bath at 95 Degree-Sign C. This time can be reduced to 3 min only by applying microwave supported heating. {sup 44}Sc-DOTATOC was found to be stable in 0.9% NaCl, PBS pH 7.4, fetal calf and human serums, and also in the presence of competing metal cations (Fe{sup 3+}, Ca{sup 2+}, Cu{sup 2+}, Mg{sup 2+}), as well as other ligand competitors, like EDTA and DTPA, even after almost 25 h incubation at 37 Degree-Sign C. Present study shows that nca {sup 44}Sc forms stable complexes with the macrocyclic ligand DOTA and that {sup 44}Sc-DOTATOC and analog targeting vectors may be synthesized for further preclinical and clinical investigations. - Highlights: Black-Right-Pointing-Pointer Labeling of somatostatin analouges with positron emitter {sup 44}Sc was tested. Black-Right-Pointing-Pointer DOTATOC was labeled with {sup 44}Sc isotope. Black-Right-Pointing-Pointer Optimal conditions for {sup 44}Sc-DOTATOC synthesis were found. Black-Right-Pointing-Pointer Stability of {sup 44}Sc

  17. Electron source with the explosion-emission cathode on the base of Bi-Sr-Ca-Cu-O ceramics

    International Nuclear Information System (INIS)

    Korenev, S.A.

    1996-01-01

    Two electron sources with explosion-emission cathode on the basis of Bi 2 Sr 2 Ca 2 Cu 3 O x ceramics are described. The scheme of electron gun for formation of electron beams of microsecond length consists of vacuum chamber, flow-passage insulator and cathode with ceramic emitter. The pulse duration by 600 kV voltage equals 1 μs. The split anode, two short magnetic lenses and Rogovsky belt are used for production of low-energy beams. The nanosecond electrical beams with energy of 10-25 keV were produced through this electron source. The beam cross-sectional non-uniformity did not exceed 5% by the beam diameter of 1 cm. 11 refs., 4 figs

  18. Probing the emitter site of Renilla luciferase using small organic molecules; an attempt to understand the molecular architecture of the emitter site.

    Science.gov (United States)

    Salehi, Farajollah; Emamzadeh, Rahman; Nazari, Mahboobeh; Rasa, Seyed Mohammad Mahdi

    2016-12-01

    Renilla luciferase is a sensitive enzyme and has wide applications in biotechnology such as drug screening. Previous studies have tried to show the catalytic residues, nevertheless, the accurate architecture and molecular behavior of its emitter site remains uncharacterized. In this study, the activity of Renilla luciferase, in the presence of two small organic molecules including dimethyl sulfoxide (DMSO) and isopropanol was considered and the structure was studied by circular dichroism (CD) and fluorescence spectroscopy. Moreover, the interaction of small organic molecules with the Renilla luciferase was studied using molecular dynamics simulations. Kinetics studies showed that at low concentration of DMSO (16.6-66mM) and isopropanol (19.3-76mM) the K m changed and a competitive inhibition pattern was observed. Moreover, spectroscopy studies reveled that the changes of activity of Renilla luciferase in the presence of low concentrations of small organic molecules was not associated with structural collapse or severe changes in the enzyme conformation. Molecular dynamics simulations indicated that DMSO and isopropanol, as probing molecules, were both able to bind to the emitter site and remained with the residues of the emitter site. Based on the probing data, the architecture of the emitter site in the "non-binding" model was proposed. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Strong nonlinearity-induced correlations for counterpropagating photons scattering on a two-level emitter

    DEFF Research Database (Denmark)

    Nysteen, Anders; McCutcheon, Dara; Mørk, Jesper

    2015-01-01

    We analytically treat the scattering of two counterpropagating photons on a two-level emitter embedded in an optical waveguide. We find that the nonlinearity of the emitter can give rise to significant pulse-dependent directional correlations in the scattered photonic state, which could be quanti......We analytically treat the scattering of two counterpropagating photons on a two-level emitter embedded in an optical waveguide. We find that the nonlinearity of the emitter can give rise to significant pulse-dependent directional correlations in the scattered photonic state, which could...

  20. Emittance scans for CMS luminosity calibration in 2017

    CERN Document Server

    CMS Collaboration

    2018-01-01

    Emittance scans are short van der Meer type scans performed at the beginning and at the end of LHC fills. The beams are scanned against each other in X and Y planes in 7 displacement steps. These scans are used for LHC diagnostics and since 2017 for a cross check of the CMS luminosity calibration. An XY pair of scans takes around 3 minutes. The BRIL project provides to LHC three independent online luminosity measurement from the Pixel Luminosity Telescope (PLT), the Fast Beam Condition Monitor (BCM1F) and the Forward calorimeter (HF). The excellent performance of the BRIL detector front-ends, fast back-end electronics and CMS XDAQ based data processing and publication allow the use of emittance scans for linearity and stability studies of the luminometers. Emittance scans became a powerful tool and dramatically improved the understanding of the luminosity measurement during the year. Since each luminometer is independently calibrated in every scan the measurements are independent and ratios of luminometers ca...

  1. Low Emittance Gun Project based on Field Emission

    CERN Document Server

    Ganter, Romain; Dehler, M; Gobrecht, Jens; Gough, Chris; Ingold, Gerhard; Leemann, Simon C; Shing-Bruce-Li, Kevin; Paraliev, Martin; Pedrozzi, Marco; Raguin, Jean Yves; Rivkin, Leonid; Schlott, Volker; Sehr, Harald; Streun, Andreas; Wrulich, Albin F; Zelenika, Sasa

    2004-01-01

    The design of an electron gun capable of producing beam emittance one order of magnitude lower than current technology would reduce considerably the cost and size of a free electron laser emitting at 0.1nm. Field emitter arrays (FEAs) including a gate and a focusing layer are an attractive technology for such high brightness sources. Electrons are extracted from micrometric tips thanks to voltage pulses between gate and tips. The focusing layer should then reduce the initial divergence of each emitted beamlets. This FEA will be inserted in a high gradient diode configuration coupled with a radiofrequency structure. In the diode part very high electric field pulses (several hundreds of MV/m) will limit the degradation of emittance due to space charge effect. This first acceleration will be obtained with high voltage pulses (typically a megavolt in a few hundred of nanoseconds) synchronized with the low voltage pulses applied to the FEA (typically one hundred of volts in one nanosecond at frequency below kilohe...

  2. Control and Data Analysis for Emittance Measuring Devices

    CERN Document Server

    Hoffmann, T

    2001-01-01

    Due to the wide range of heavy ion beam intensities and energies in the GSI linac and the associated transfer channel to the synchrotron, several different types of emittance measurement systems have been established. Many common devices such as slit/grid or dipole-sweep systems are integrated into the GSI control system. Other systems like the single shot pepper pot method using CCD-cameras or stand-alone slit/grid set-ups are connected to personal computers. An overview is given about the various systems and their software integration. Main interest is directed on the software development for emittance front-end control and data analysis such as evaluation algorithms or graphical presentation of the results. In addition, special features for improved usability of the software such as data export, project databases and automatic report generation will be presented. An outlook on a unified evaluation procedure for all different types of emittance measurement is given.

  3. Superconducting wiggler magnets for beam-emittance damping rings

    CERN Document Server

    Schoerling, Daniel

    2012-01-01

    Ultra-low emittance beams with a high bunch charge are necessary for the luminosity performance of linear electron-positron colliders, such as the Compact Linear Collider (CLIC). An effective way to create ultra-low emittance beams with a high bunch charge is to use damping rings, or storage rings equipped with strong damping wiggler magnets. The remanent field of the permanent magnet materials and the ohmic losses in normal conductors limit the economically achievable pole field in accelerator magnets operated at around room temperature to below the magnetic saturation induction, which is 2.15 T for iron. In wiggler magnets, the pole field in the center of the gap is reduced further like the hyperbolic cosine of the ratio of the gap size and the period length multiplied by pi. Moreover, damping wiggler magnets require relatively large gaps because they have to accept the un-damped beam and to generate, at a small period length, a large magnetic flux density amplitude to effectively damp the beam emittance....

  4. Nanometer emittance ultralow charge beams from rf photoinjectors

    Directory of Open Access Journals (Sweden)

    R. K. Li

    2012-09-01

    Full Text Available In this paper we discuss the generation of a new class of high brightness relativistic electron beams, characterized by ultralow charge (0.1–1 pC and ultralow normalized emittance (<50  nm. These beams are created in rf photoinjectors when the laser is focused on the cathode to very small transverse sizes (<30  μm rms. In this regime, the charge density at the cathode approaches the limit set by the extraction electric field. By shaping the laser pulse to have a cigarlike aspect ratio (the longitudinal dimension much larger than the transverse dimension and a parabolic temporal profile, the resulting space charge dominated dynamics creates a uniformly filled ellipsoidal distribution and the emittance can be nearly preserved to its thermal value. We also present a new method, based on a variation of the pepper-pot technique, for single shot measurements of the ultralow emittances for this new class of beams.

  5. Gamma-ray response of NE-213 measured between 2 and 11.5 MeV

    International Nuclear Information System (INIS)

    Ingersoll, D.T.; Wehring, B.W.; Starr, R.D.

    1976-01-01

    Because of the capability to discriminate between neutrons and gamma rays, NE-213 scintillators are useful as both fast-neutron and gamma-ray spectrometers. However, measured NE-213 Compton-recoil spectra require unfolding to yield gamma-ray energy spectra which entails a detailed knowledge of the gamma-ray response of the NE-213 detector system. Absolute measurements of the gamma-ray response of an NE-213 scintillator in the energy range of 2 to 11.5 MeV were made. The measurements were made using the University of Illinois superconducting electron microtron equipped with a gamma-ray monochromator. The response measurements will be used to construct a gamma-ray response matrix for NE-213 to be used with the FORIST unfolding code

  6. Experimental Studies for the VVER-440/213 Bubble Condenser System for Kola NPP at the Integral Test Facility BC V-213

    International Nuclear Information System (INIS)

    Blinkov, V.N.; Melikhov, O.I.; Melikhov, V.I.; Davydov, M.V.; Wolff, H.; Arndt, S.

    2012-01-01

    In the frame of Tacis Project R2.01/99, which was running from 2003 to 2005, the bubble condenser system of Kola NPP (unit 3) was qualified at the integral test facility BC V-213. Three LB LOCA tests, two MSLB tests, and one SB LOCA test were performed. The appropriate test scenarios for BC V-213 test facility, modeling accidents in the Kola NPP unit 3, were determined with pretest calculations. Analysis of test results has shown that calculated initial conditions and test scenarios were properly reproduced in the tests. The detailed posttest analysis of the tests performed at BC V-213 test facility was aimed to validate the COCOSYS code for the calculation of thermohydraulic processes in the hermetic compartments and bubble condenser. After that the validated COCOSYS code was applied to NPP calculations for Kola NPP (unit 3). Results of Tacis R2.01/99 Project confirmed the bubble condenser functionality during large and small break LOCAs and MSLB accidents. Maximum loads were reached in the LB LOCA case. No condensation oscillations were observed.

  7. Graphene field emitters: A review of fabrication, characterization and properties

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Leifeng, E-mail: chlf@hdu.edu.cn [College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018 (China); State Key Laboratory of Silicon Materials, Zhejiang University, Hangzhou 310027 (China); Yu, Hu; Zhong, Jiasong; Song, Lihui [College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018 (China); Wu, Jun, E-mail: wujun@hdu.edu.cn [Institute of Electron Device & Application, Hangzhou Dianzi University, Hangzhou, Zhejiang 310018 (China); Su, Weitao [College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018 (China)

    2017-06-15

    Highlights: • The preparation, characterization and field emission properties for Gs are reviewed. • The review provides an updated progress on design and construction of Gs field emitters. • The review offers fundamental insights into understanding and design of Gs emitters. • The review can broach the subject and inspire readers in field of Gs based emitters. - Abstract: Graphenes are beneficial to electrons field emission due to its high aspect ratio, high carrier density, the larger carrier mobility, excellent electrical and thermal conductivity, excellent mechanical strength and chemical stability. In recent years, graphene or reduced oxide graphene field emitters have been successfully constructed by various methods such as chemical vapor deposition, chemical exfoliation, electrophoretic deposition, screen-printing and chemical synthesis methods. Graphene emitters are tried to construct in distribution with some angles or vertical orientation with respect to the substrate surface. The vertical alignment of graphene sheets or edges arrays can facilitate efficient electron emission from the atomically thick sheets. Therefore they have even more a low turn-on and threshold-field electronic field, high field enhancement factor, high current stability and high luminance. In this review, we shortly survey and discuss recent research progress in graphene field emission properties with particular an emphasis on their preparing method, characterization and applications in devices especially for vertical graphene and single layer graphene, also including their challenges and future prospects.

  8. Preparation, characterization and enhanced visible-light photocatalytic activities of BiPO4/BiVO4 composites

    International Nuclear Information System (INIS)

    Wu, Siyuan; Zheng, Hong; Lian, Youwei; Wu, Yiying

    2013-01-01

    Graphical abstract: - Highlights: • BiPO 4 /BiVO 4 composites were successfully prepared by the hydrothermal method. • BiPO 4 /BiVO 4 composites exhibited broad absorption in the visible region. • Visible-light photocatalytic activities of BiPO 4 /BiVO 4 composites were enhanced. • P/V molar ratio and pH value of the reaction affect photocatalytic activity. • The mechanism of enhanced visible-light photocatalytic activities was discussed. - Abstract: BiPO 4 /BiVO 4 composites with different P/V molar ratios were prepared by the hydrothermal method and the effect of pH values of hydrothermal reaction on photocatalytic activity of BiPO 4 /BiVO 4 composite was investigated. The photocatalysts were characterized by X-ray diffraction, field emission scanning electron microscopy, energy-dispersive spectroscopy, X-ray photoelectron spectroscopy and UV–vis diffuse reflectance spectroscopy. The photocatalytic property of BiPO 4 /BiVO 4 was evaluated by photocatalytic degradation of Methylene blue under visible light irradiation. The results showed that the photocatalytic activity of the composites was much higher than that of pure BiPO 4 and BiVO 4 . The rate constant of Methylene blue degradation over BiPO 4 /BiVO 4 (P/V molar ratio of 5:1 and hydrothermal reaction pH value of 1.5) is 1.7 times that of pure BiVO 4 . The photocatalytic activity enhancement of BiPO 4 /BiVO 4 composite is closely related to the BiVO 4 functioning as a sensitizer to adsorb visible light and the heterojunction of BiPO 4 /BiVO 4 acting as an active center for hindering the rapid recombination of electron–hole pairs during the photocatalytic reaction

  9. Spatial profile of thermoelectric effects during Peltier pulsing in Bi and Bi/MnBi eutectic

    Science.gov (United States)

    Silberstein, R. P.; Larson, D. J., Jr.

    1987-01-01

    The spatial profile of the thermal transients that occur during and following the current pulsing associated with Peltier Interface Demarcation during directional solidification is studied. Results for pure Bi are presented in detail and compared with corresponding results for the Bi/MnBi eutectic. Significant thermal transients occur throughout the sample that can be accounted for by the Peltier effect, the Thomson effect, and Joule heating. These effects are separated and their behavior is studied as a function of time, current density, and position with respect to the solid/liquid interface.

  10. Studies and calculations of transverse emittance growth in proton storage rings

    International Nuclear Information System (INIS)

    Mane, S.R.; Jackson, G.

    1989-01-01

    When high energy storage rings are used to collide beams of particles and antiparticles for high energy physics experiments, it is important to obtain as high an integrated luminosity as possible. Reduction of integrated luminosity can arise from several factors, in particular from growth of the transverse beam sizes (transverse emittances). We have studied the problem of transverse emittance growth in high energy storage rings caused by random dipole noise kicks to the beam. A theoretical formula for the emittance growth rate is derived, and agreement is obtained with experimental measurements where noise of known amplitude and power spectrum was deliberately injected into the Fermilab Tevatron, to kick the beam randomly. In the experiment, phase noise was introduced into the Tevatron rf system, and the measured dependence of horizontal emittance growth on phase noise amplitude is compared against the theoretically derived response. (orig.)

  11. State diagram of Pr-Bi system

    International Nuclear Information System (INIS)

    Abulkhaev, V.L.; Ganiev, I.N.

    1994-01-01

    By means of thermal differential analysis, X-ray and microstructural analysis the state diagram of Pr-Bi system was studied. Following intermetallic compounds were defined in the system: Pr 2 Bi, Pr 5 Bi 3 , Pr 4 Bi 3 , Pr Bi, PrBi 2 , Pr 2 Bi, Pr 5 Bi 3 , Pr 4 Bi 3 and PrBi 2 . The data analysis on Ln-Bi diagram allowed to determine the regularity of change of properties of intermetallic compounds in the line of rare earth elements of cerium subgroup.

  12. Emittances Studies at the Fermilab/NICADD Photoinjector Laboratory

    CERN Document Server

    Tikhoplav, Rodion; Melissinos, A C; Regis-Guy Piot, Philippe

    2005-01-01

    The Fermilab/NICADD photoinjector incorporates an L-band rf-gun capable of generating 1-10 nC bunches. The bunches are then accelerated to 16 MeV with a TESLA superconducting cavity. In the present paper we present parametric studies of transverse emittances and energy spread for a various operating points of the electron source (RF-gun E-field, laser length and spot size, and solenoid settings). We especially study the impact, on transverse emittance, of Gaussian and Plateau temporal distribution of the photocathode drive-laser.

  13. LabVIEW Data Acquisition for NE213 Neutron Detector

    International Nuclear Information System (INIS)

    Gangadharan, Dhevan

    2003-01-01

    A neutron spectroscopy system based on a NE213 liquid scintillation detector at the Stanford Linear Accelerator Center measures neutron energies from a few MeV up to 800 MeV. The neutrons are produced from the electron beam and target interactions. The NE 213 scintillator, coupled with a Photomultiplier Tube (PMT), detects and converts radiation into electric pulses for signal processing. Signals are processed through Nuclear Instrument Modules (NIM) and Computer Automated Measurement and Control (CAMAC) modules. The processed pulses are then fed into a CAMAC analog to digital converter module (ADC). The ADC classifies the incoming analog pulses into one of 2048 digital channels. Data acquisition (DAQ) software based on LabVIEW version 7.0 acquires and organizes data from the CAMAC ADC. The DAQ system presents a spectrum showing a relationship between pulse events and respective charge (digital channel number). Various photon sources, such as Co-60, Y-88, and AmBe-241, are used to calibrate the NE213 detector. For each source, a Compton edge and reference energy in MeVee is obtained, resulting in a calibration curve. This project is focused on the development of a DAQ system and control setup to collect and process information from a NE213 liquid scintillation detector. A manual is also created to document the process of the development and interpretation of the LabVIEW-based DAQ system

  14. Simple emittance measurement of H- beams from a large plasma source

    International Nuclear Information System (INIS)

    Guharay, S.K.; Tsumori, K.; Hamabe, M.; Takeiri, Y.; Kaneko, O.; Kuroda, T.

    1996-03-01

    An emittance meter is developed using pepper-pot method. Kapton foils are used to detect intensity distributions of small beamlets at the 'image' plane of the pepper-pot. Emittance of H - beams from a large plasma source for the neutral beam injector of the Large Helical Device (LHD) has been measured. The normalized emittance (95%) of a 6 mA H - beam with emission current density of about 10 mA/cm 2 is ∼0.59 mm mrad. The present system is very simple, and it eliminates many complexities of the existing schemes. (author)

  15. Achievement of ultra-low emittance beam in the ATF damping ring

    CERN Document Server

    Honda, Y; Araki, S; Bane, Karl Leopold Freitag; Brachmann, A; Frisch, J; Fukuda, M; Hasegawa, K; Hayano, H; Hendrickson, L; Higashi, Y; Higo, T; Hirano, K; Hirose, T; Iida, K; Imai, T; Inoue, Y; Karataev, P; Kubo, K; Kurihara, Y; Kuriki, M; Kuroda, R; Kuroda, S; Luo, X; Matsuda, M; McCormick, D; Muto, T; Nakajima, K; Nelson, J; Nomura, M; Ohashi, A; Okugi, T; Omori, T; Ross, M; Sakai, H; Sakai, I; Sasao, N; Smith, S; Suzuki, T; Takano, M; Takashi, N; Taniguchi, T; Terunuma, N; Toge, N; Turner, J; Urakawa, J; Vogel, V; Wolski, A; Woodley, M; Yamazaki, I; Yamazaki, Y; Yocky, J; Young, A; Zimmermann, Frank

    2003-01-01

    We report on the smallest vertical emittance achieved in single-bunch-mode operation of the ATF. The emittances were measured with a laser-wire beam-profile monitor installed in the damping ring. The bunch length and the momentum spread of the beam were also recorded under the same conditions. The smallest vertical rms emittance measured is 4 pm in the limit of zero current. It increases by a factor of 1.5 for a bunch intensity of 10^10 electrons. There are no discrepancies between the measured data and the calculations of intra-beam scattering.

  16. Minimum emittance of isochronus rings for synchrotron light source

    CERN Document Server

    Shoji, Y

    1999-01-01

    Theoretically achievable minimum emittances of isochronus rings for synchrotron light source are calculated. The rings discussed in this paper consist of isochronus and achromatic bending cells, isochronus TBA (triple bend achromat) cells with negative dispersion, isochronus TBA cells with inverse bends or isochronus QBA (four bend achromat) cells. We show that the minimum emittances of these rings are roughly 2 or 3 times of those of the optimized non-isochronus rings.

  17. Emittance growth from rotated quadrupoles in heavy ion accelerators

    International Nuclear Information System (INIS)

    Barnard, J.J.

    1995-01-01

    We derive a set of moment equations which incorporates linear quadrupolar focusing and space-charge defocusing, in the presence of rotational misalignments of the quadrupoles about the direction of beam propagation. Although the usual beam emittance measured relative to fixed transverse x and y coordinate axes is not constant, a conserved emittance-like quantity has been found. Implications for alignment tolerances in accelerators for heavy-ion inertial fusion are discussed

  18. 24 CFR 213.259a - Premiums-mortgages insured pursuant to section 238(c) of the Act.

    Science.gov (United States)

    2010-04-01

    .... All of the provisions of §§ 213.253 through 213.259 governing mortgage insurance premiums shall apply... mortgage insurance premiums due on such mortgages in accordance with §§ 213.253 through 213.259 shall be... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Premiums-mortgages insured pursuant...

  19. Ghost signals in Allison emittance scanners

    International Nuclear Information System (INIS)

    Stockli, Martin P.; Leitner, M.; Moehs, D.P.; Keller, R.; Welton, R.F.

    2004-01-01

    For over 20 years, Allison scanners have been used to measure emittances of low-energy ion beams. We show that scanning large trajectory angles produces ghost signals caused by the sampled beamlet impacting on an electric deflection plate. The ghost signal strength is proportional to the amount of beam entering the scanner. Depending on the ions, and their velocity, the ghost signals can have the opposite or the same polarity as the main beam signals. The ghost signals cause significant errors in the emittance estimates because they appear at large trajectory angles. These ghost signals often go undetected because they partly overlap with the real signals, are mostly below the 1% level, and often hide in the noise. A simple deflection plate modification is shown to reduce the ghost signal strength by over 99%

  20. Ghost Signals In Allison Emittance Scanners

    International Nuclear Information System (INIS)

    Stockli, Martin P.; Leitner, M.; Keller, R.; Moehs, D.P.; Welton, R. F.

    2005-01-01

    For over 20 years, Allison scanners have been used to measure emittances of low-energy ion beams. We show that scanning large trajectory angles produces ghost signals caused by the sampled beamlet impacting on an electric deflection plate. The ghost signal strength is proportional to the amount of beam entering the scanner. Depending on the ions, and their velocity, the ghost signals can have the opposite or the same polarity as the main beam signals. The ghost signals cause significant errors in the emittance estimates because they appear at large trajectory angles. These ghost signals often go undetected because they partly overlap with the real signals, are mostly below the 1% level, and often hide in the noise. A simple deflection plate modification is shown to reduce the ghost signal strength by over 99%

  1. Computing Eigen-Emittances from Tracking Data

    Energy Technology Data Exchange (ETDEWEB)

    Alexahin, Y. [Fermilab

    2014-09-18

    In a strongly nonlinear system the particle distribution in the phase space may develop long tails which contribution to the covariance (sigma) matrix should be suppressed for a correct estimate of the beam emittance. A method is offered based on Gaussian approximation of the original particle distribution in the phase space (Klimontovich distribution) which leads to an equation for the sigma matrix which provides efficient suppression of the tails and cannot be obtained by introducing weights. This equation is easily solved by iterations in the multi-dimensional case. It is also shown how the eigen-emittances and coupled optics functions can be retrieved from the sigma matrix in a strongly coupled system. Finally, the developed algorithm is applied to 6D ionization cooling of muons in HFOFO channel.

  2. Optical characterization of OLED emitter properties by radiation pattern analyses

    Energy Technology Data Exchange (ETDEWEB)

    Flaemmich, Michael

    2011-09-08

    Researches in both, academia and industry are investigating optical loss channels in OLED layered systems by means of optical simulation tools in order to derive promising concepts for a further enhancement of the overall device performance. Besides other factors, the prospects of success of such optimization strategies rely severely on the credibility of the optical input data. The present thesis provides a guideline to measure the active optical properties of OLED emitter materials in situ by radiation pattern analyses. Reliable and widely applicable methods are introduced to determine the internal electroluminescence spectrum, the profile of the emission zone, the dipole emitter orientation, and the internal luminescence quantum efficiency of emissive materials from the optical far field emission of OLEDs in electrical operation. The proposed characterization procedures are applied to sets of OLEDs containing both, fluorescent polymeric materials as well as phosphorescent small-molecular emitters, respectively. On the one hand, quite expected results are obtained. On the other hand, several novel and truly surprising results are found. Most importantly, this thesis contains the first report of a non-isotropic, mainly parallel emitter orientation in a phosphorescent small-molecular guest-host system (Ir(MDQ)2(acac) in a-NPD). Due to the latter result, emitter orientation based optimization of phosphorescent OLEDs seems to be within reach. Since parallel dipoles emit preferably into air, the utilization of smart emissive materials with advantageous molecular orientation is capable to boost the efficiency of phosphorescent OLEDs by 50%. Materials design, the influence of the matrix material and the substrate, as well as film deposition conditions are just a few parameters that need to be studied further in order to exploit the huge potential of the dipole emitter orientation in phosphorescent OLEDs.

  3. Sub-nanometer emittance monitor for high brightness synchrotron radiation source

    International Nuclear Information System (INIS)

    Nakajima, K.

    1991-01-01

    Method of measuring a very small beam emittance in electron storage rings is presented. The monitor can sense an intrinsic emittance of beam particles by detecting the angular distribution of Compton scatterings of laser photons on beam electrons. It is possible to achieve measurement resolution smaller than 10 -9 m-rad without difficulty. (author)

  4. One-step growth of nanosheet-assembled BiOCl/BiOBr microspheres for highly efficient visible photocatalytic performance

    Science.gov (United States)

    Zhang, Jinfeng; Lv, Jiali; Dai, Kai; Liang, Changhao; Liu, Qi

    2018-02-01

    In this work, we have developed a simple synthetic approach of nanosheet-assembled BiOCl/BiOBr microspheres by an ethylene glycol (EG)-assisted hydrothermal method. The crystalline form, morphology, chemical composition, optical performance and surface area of BiOCl/BiOBr microspheres were identified using X-ray diffraction (XRD), transmission electron microscopy (TEM), high resolution TEM (HRTEM), scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy spectra (EDX), UV-vis diffuse reflectance spectroscopy (DRS) analysis, high resolution X-ray photoelectron spectra (XPS) and N2 adsorption-desorption isotherms. BiOCl/BiOBr microspheres were nanosheet-assembled particles, which possessed visible light absorption under LED light irridation. Additionally, the methylene blue (MB) photodegradation performance of different BiOCl/BiOBr microspheres irradiated under 410 nm LED light arrays were investigated, the results exhibited that as-prepared BiOCl/BiOBr products showed higher catalytic effiency than pure BiOCl or BiOBr. By optimizing the composition ration of the BiOCl and BiOBr, up to 93% degradation rate can be obtained in the 40%BiOCl/BiOBr microspheres. Finally, the photocatalytic mechanism of BiOCl/BiOBr microspheres had been proposed.

  5. Normal spectral emittance of Inconel 718 aeronautical alloy coated with yttria stabilized zirconia films

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Fernandez, L. [Departamento de Fisica de la Materia Condensada, Facultad de Ciencia y Tecnologia, Universidad del Pais Vasco, Barrio Sarriena s/n, 48940 Leioa, Bizkaia (Spain); Industria de Turbo Propulsores, S.A., Planta de Zamudio, Edificio 300, 48170 Zamudio, Bizkaia (Spain); Campo, L. del [Departamento de Fisica de la Materia Condensada, Facultad de Ciencia y Tecnologia, Universidad del Pais Vasco, Barrio Sarriena s/n, 48940 Leioa, Bizkaia (Spain); Perez-Saez, R.B., E-mail: raul.perez@ehu.es [Departamento de Fisica de la Materia Condensada, Facultad de Ciencia y Tecnologia, Universidad del Pais Vasco, Barrio Sarriena s/n, 48940 Leioa, Bizkaia (Spain); Tello, M.J. [Departamento de Fisica de la Materia Condensada, Facultad de Ciencia y Tecnologia, Universidad del Pais Vasco, Barrio Sarriena s/n, 48940 Leioa, Bizkaia (Spain)

    2012-02-05

    Highlights: Black-Right-Pointing-Pointer Emittance of Inconel 718 coated with plasma sprayed yttria stabilized zirconia. Black-Right-Pointing-Pointer The coating is opaque for {lambda} > 9 {mu}m and semi-transparent for {lambda} < 9 {mu}m. Black-Right-Pointing-Pointer In the semi-transparent region the emittance decreases with coating thickness. Black-Right-Pointing-Pointer 300 {mu}m thick coatings are still semi-transparent. Black-Right-Pointing-Pointer In the opaque region the surface roughness determines the emittance level. - Abstract: Knowledge of the radiative behaviour of the yttria stabilized zirconia (YSZ) thermal barrier coatings (TBCs) is needed to perform radiative heat transfer calculations in industrial applications. In this paper, normal spectral emittance experimental data of atmospheric plasma sprayed (PS) YSZ films layered on Inconel 718 substrates are shown. The spectral emittance was measured between 2.5 and 22 {mu}m on samples with film thicknesses ranging from 20 to 280 {mu}m. The samples were heated in a controlled environment, and the emittance was measured for several temperatures between 330 and 730 Degree-Sign C. The dependence of the spectral emittance with film thickness, surface roughness and temperature has been studied and compared with the available results for YSZ TBCs obtained by electron-beam physical vapour deposition. The PS-TBC samples show a Christiansen point at {lambda} = 12.8 {mu}m. The films are semi-transparent for {lambda} < 9 {mu}m, and opaque for {lambda} > 9 {mu}m. In the semi-transparent region, the contribution of the radiation emitted by the Inconel 718 substrate to the global emittance of the samples is analysed. In addition, the influence of the roughness in the emittance values in the opaque spectral region is discussed. Finally, the total normal emittance is obtained as a function of the TBC thickness.

  6. The emittance of high current heavy ion beams

    International Nuclear Information System (INIS)

    White, N.R.; Devaney, A.S.

    1989-01-01

    Ion implantation is the main application for high current heavy ion beams. Transfer ratio is defined as the ratio of the total ion current leaving the ion source to the current delivered to the endstation. This ratio is monitored and logged and its importance is explained. It is also affected by other factors, such as the isotopic and molecular composition of the total ion beam. The transfer ratio reveals the fraction of ions which are intercepted by parts of the beamline system. The effects of these ions are discussed in two categories: processing purity and reliability. In discussing the emittance of ribbon beams, the two orthogonal planes are usually considered separately. Longitudinal emittance is determined by slot length and by plasma ion temperature. It has already been revealed that the longitudinal divergence of the beams from BF3 is perhaps double that of the beam from arsenic vapour or argon, at the same total perveance from the ion source. This poses the question: why is the ion temperature higher for BF3 than for As or Ar? The transverse emittance is in practical terms dominated by the divergence. It is the most fruitful area for improvement in most real-world systems. There is an intrinsic divergence arising from initial ion energies within the plasma, and there is emittance growth that can occur as a result of aberration in the beam extraction optics. (N.K.)

  7. Development and labeling of EP-00652218 analogues, NK1 receptors antagonist, for PET and SPECT imaging

    International Nuclear Information System (INIS)

    Bagot-Gueret, C.

    2001-12-01

    The aim of this work was the synthesis and radiosynthesis of compounds labelled either with a positron emitter (fluorine-18, t 1/2 = 109 minutes) or with a gamma emitter (iodine-123, t 1/2 = 16.2 hours), for Positron Emission Tomography (PET) and Single Photon Emission Computed Tomography (SPECT) studies. EP-00652218 is a novel potent antagonist, with a sub-nano-molar affinity towards the NK 1 receptors. In order to develop ligands that could be used either in PET or SPECT, we undertook the synthesis of poly-halogenated analogues of EP-00652218. Compound 17 was synthesized through two different synthetic pathways. A series of original compounds has been obtained from compound 17 by halogen exchanges on the naphthyridone or the benzene ring. These molecules were tested to determine their in vitro affinity towards NK 1 receptors. Compound 21 was labelled with fluorine-18 in 135 minutes and with a 20% radiochemical yield. Compound 26 was radioiodinated following reaction with Na 125 I (t 1/2 = 60.14 days) in a 18% radiochemical yield. Despite expectation, these analogues of EP-00652218 exhibited an insufficient affinity for NK 1 receptors (IC 50 = 10 -7 M) and thus unlikely usable for in vivo studies with PET and SPECT. (author)

  8. Emittance control and RF bunch compression in the NSRRC photoinjector

    International Nuclear Information System (INIS)

    Lau, W.K.; Hung, S.B.; Lee, A.P.; Chou, C.S.; Huang, N.Y.

    2011-01-01

    The high-brightness photoinjector being constructed at the National Synchrotron Radiation Research Center is for testing new accelerator and light-source concepts. It is the so-called split photoinjector configuration in which a short solenoid magnet is used for emittance compensation. The UV-drive laser pulses are also shaped to produce uniform cylindrical bunches for further reduction of beam emittance. However, limited by the available power from our microwave power system, the nominal accelerating gradient in the S-band booster linac is set at 18 MV/m. A simulation study with PARMELA shows that the linac operating at this gradient fails to freeze the electron beam emittance at low value. A background solenoid magnetic field is applied for beam emittance control in the linac during acceleration. A satisfactory result that meets our preliminary goal has been achieved with the solenoid magnetic field strength at 0.1 T. RF bunch compression as a means to achieve the required beam brightness for high-gain free-electron laser experiments is also examined. The reduction of bunch length to a few hundred femtoseconds can be obtained.

  9. Benchmarking of measurement and simulation of transverse rms-emittance growth

    Directory of Open Access Journals (Sweden)

    L. Groening

    2008-09-01

    Full Text Available Transverse emittance growth along the Alvarez drift tube linac (DTL section is a major concern with respect to the preservation of beam quality of high current beams at the GSI UNILAC. In order to define measures to reduce this growth, appropriate tools to simulate the beam dynamics are indispensable. This paper is about the benchmarking of three beam dynamics simulation codes, i.e. DYNAMION, PARMILA, and PARTRAN against systematic measurements of beam emittances for different transverse phase advances along the DTL. Special emphasis is put on the modeling of the initial distribution for the simulations. The concept of rms equivalence is expanded from full intensity to fractions of less than 100% of the beam. The experimental setup, data reduction, preparation of the simulations, and the evaluation of the simulations are described. In the experiments and in the simulations, a minimum of the rms-emittance growth was observed at zero current phase advances of about 60°. In general, good agreement was found between simulations and experiment for the mean values of horizontal and vertical emittances at the DTL exit.

  10. High efficiency and stable white OLED using a single emitter

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jian [Arizona State Univ., Tempe, AZ (United States). School of Mechanical, Aerospace, Chemical and Materials Engineering

    2016-01-18

    The ultimate objective of this project was to demonstrate an efficient and stable white OLED using a single emitter on a planar glass substrate. The focus of the project is on the development of efficient and stable square planar phosphorescent emitters and evaluation of such class of materials in the device settings. Key challenges included improving the emission efficiency of molecular dopants and excimers, controlling emission color of emitters and their excimers, and improving optical and electrical stability of emissive dopants. At the end of this research program, the PI has made enough progress to demonstrate the potential of excimer-based white OLED as a cost-effective solution for WOLED panel in the solid state lighting applications.

  11. Measuring Beam Sizes and Ultra-Small Electron Emittances Using an X-ray Pinhole Camera.

    Science.gov (United States)

    Elleaume, P; Fortgang, C; Penel, C; Tarazona, E

    1995-09-01

    A very simple pinhole camera set-up has been built to diagnose the electron beam emittance of the ESRF. The pinhole is placed in the air next to an Al window. An image is obtained with a CCD camera imaging a fluorescent screen. The emittance is deduced from the size of the image. The relationship between the measured beam size and the electron beam emittance depends upon the lattice functions alpha, beta and eta, the screen resolution, pinhole size and photon beam divergence. The set-up is capable of measuring emittances as low as 5 pm rad and is presently routinely used as both an electron beam imaging device and an emittance diagnostic.

  12. Auger electron emitters: Insights gained from in vitro experiments

    International Nuclear Information System (INIS)

    Makrigiorgos, G.; Adelstein, S.J.; Kassis, A.I.

    1990-01-01

    This paper outlines the evolution of the current rationale for research into the biological effects of tissue-incorporated Auger electron emitters. The first section is a brief review of the research conducted by several groups in the last fifteen years. The second section describes the in vitro model used in our studies, dosimetric calculations, experimental techniques and recent findings. The third section focuses on the use of Auger electron emitters as in vitro microprobes for the investigation of the radiosensitivity of distinct subcellular components. Examination of the biological effects of the Auger electron emitter 125 I located in different cellular compartments of a single cell line (V 79 hamster lung fibroblast) verifies that DNA is the critical cell structure for radiation damage and that the sensitive sites are of nanometer dimensions. The data from incorporation of several Auger electron emitters at the same location within DNA suggest that there are no saturation effects from the decay of these isotopes (i.e. all the emitted energy is biologically effective) and provide some insight into which of the numerous physical mechanisms accompanying the Auger decay are most important in causing cell damage. Finally the implications of Auger electron emission for radiotherapy and radiation protection in diagnostic nuclear medicine are detailed and further research possibilities are suggested. (orig.)

  13. Beam emittance reduction during operation of Indus-2

    Energy Technology Data Exchange (ETDEWEB)

    Fakhri, Ali Akbar, E-mail: fakhri@rrcat.gov.in; Kant, Pradeep; Ghodke, A. D.; Singh, Gurnam [Raja Ramanna Centre for Advanced Technology, Indore 452 013 (India)

    2015-11-15

    Indus-2 storage ring is a 2.5 GeV third generation synchrotron radiation source. This source was commissioned using a moderate optics. Beam injection was accomplished using an off momentum electron beam to avoid difficulties faced in storage of beam at 550 MeV. The injection procedure and relevant beam dynamical studies are discussed. The switch over from the moderate optics to low emittance optics is done at 2.5 GeV after storing the electron beam. The procedure evolved to reduce the beam emittance and its implementation during the operation is discussed.

  14. Nanodiamonds with photostable, sub-gigahertz linewidth quantum emitters

    Directory of Open Access Journals (Sweden)

    Toan Trong Tran

    2017-11-01

    Full Text Available Single-photon emitters with narrow linewidths are highly sought after for applications in quantum information processing and quantum communications. In this letter, we report on a bright, highly polarized near infrared single photon emitter embedded in diamond nanocrystals with a narrow, sub-GHz optical linewidth at 10 K. The observed zero-phonon line at ∼780 nm is optically stable under low power excitation and blue shifts as the excitation power increases. Our results highlight the prospect for using new near infrared color centers in nanodiamonds for quantum applications.

  15. Nanodiamonds with photostable, sub-gigahertz linewidth quantum emitters

    Science.gov (United States)

    Tran, Toan Trong; Kianinia, Mehran; Bray, Kerem; Kim, Sejeong; Xu, Zai-Quan; Gentle, Angus; Sontheimer, Bernd; Bradac, Carlo; Aharonovich, Igor

    2017-11-01

    Single-photon emitters with narrow linewidths are highly sought after for applications in quantum information processing and quantum communications. In this letter, we report on a bright, highly polarized near infrared single photon emitter embedded in diamond nanocrystals with a narrow, sub-GHz optical linewidth at 10 K. The observed zero-phonon line at ˜780 nm is optically stable under low power excitation and blue shifts as the excitation power increases. Our results highlight the prospect for using new near infrared color centers in nanodiamonds for quantum applications.

  16. Room-temperature deposition of diamond-like carbon field emitter on flexible substrates

    International Nuclear Information System (INIS)

    Chen, H.; Iliev, M.N.; Liu, J.R.; Ma, K.B.; Chu, W.-K.; Badi, N.; Bensaoula, A.; Svedberg, E.B.

    2006-01-01

    Room-temperature fabrication of diamond-like carbon electron field emitters on flexible polyimide substrate is reported. These thin film field emitters are made using an Ar gas cluster ion beam assisted C 6 vapor deposition method. The bond structure of the as-deposited diamond-like carbon film was studied using Raman spectroscopy. The field emission characteristics of the deposited films were also measured. Electron current densities over 15 mA/cm 2 have been recorded under an electrical field of about 65 V/μm. These diamond-like carbon field emitters are easy and inexpensive to fabricate. The results are promising for flexible field-emission fabrication without the need of complex patterning and tip shaping as compared to the Spindt-type field emitters

  17. DC-SC Photoinjector with Low Emittance at Peking University

    CERN Document Server

    Xiang Rong; Hao, J; Huang, Senlin; Lu Xiang Yang; Quan, Shengwen; Zhang, Baocheng; Zhao, Kui

    2005-01-01

    High average power Free Electron Lasers require the high quality electron beams with the low emittance and the sub-picosecond bunches. The design of DC-SC photoinjector, directly combining a DC photoinjector with an SRF cavity, can produce high average current beam with moderate bunch charge and high duty factor. Because of the DC gun, the emittance increases quickly at the beginning, so a carefully design is needed to control that. In this paper, the simulation of an upgraded design has been done to lower the normalized emittance below 1.5mm·mrad. The photoinjector consists of a DC gap and a 2+1/2-cell SRF cavity, and it is designed to produce 4.2 MeV electron beams at 100pC bunch charge and 81.25MHz repetition rate (8 mA average current).

  18. 33 CFR 117.213 - New Haven Harbor, Quinnipiac and Mill Rivers.

    Science.gov (United States)

    2010-07-01

    ... Mill Rivers. 117.213 Section 117.213 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... Haven Harbor, Quinnipiac and Mill Rivers. The draws of the Tomlinson bridge, mile 0.0, the Ferry Street... bridge, mile 0.4 across Mill River, shall operate as follows: (a) The draws shall open on signal; except...

  19. Calculations of emittance and damping time effects in the SLC damping rings

    International Nuclear Information System (INIS)

    Limberg, T.; Moshammer, H.; Raubenheimer, T.; Spencer, J.; Siemann, R.

    1992-03-01

    In a recent NDR machine experiment the transverse emittance was studied as a function of store time and tune. To explain the observed transverse emittance damping time constants, the magnetic measurement data of the longitudinal field of the bending magnets had to be taken into account. The variation of the transverse emittances with tune due to misalignments and the associated anomalous dispersion is studied as well as the effect of synchrobetatron coupling due to dispersion in the RF cavities

  20. LabVIEW DAQ for NE213 Neutron Detector

    International Nuclear Information System (INIS)

    Al-Adeeb, Mohammed

    2003-01-01

    A neutron spectroscopy system, based on a NE213 liquid scintillation detector, to be placed at the Stanford Linear Accelerator Center to measure neutron spectra from a few MeV up to 800 MeV, beyond shielding. The NE213 scintillator, coupled with a Photomultiplier Tube (PMT), detects and converts radiation into current for signal processing. Signals are processed through Nuclear Instrument Modules (NIM) and Computer Automated Measurement and Control (CAMAC) modules. CAMAC is a computer automated data acquisition and handling system. Pulses are properly prepared and fed into an analog to digital converter (ADC), a standard CAMAC module. The ADC classifies the incoming analog pulses into 1 of 2048 digital channels. Data acquisition (DAQ) software based on LabVIEW, version 7.0, acquires and organizes data from the CAMAC ADC. The DAQ system presents a spectrum showing a relationship between pulse events and respective charge (digital channel number). Various photon sources, such as Co-60, Y-88, and AmBe-241, are used to calibrate the NE213 detector. For each source, a Compton edge and reference energy [units of MeVee] is obtained. A complete calibration curve results (at a given applied voltage to the PMT and pre-amplification gain) when the Compton edge and reference energy for each source is plotted. This project is focused to development of a DAQ system and control setup to collect and process information from a NE213 liquid scintillation detector. A manual is created to document the process of the development and interpretation of the LabVIEW-based DAQ system. Future high-energy neutron measurements can be referenced and normalized according to this calibration curve

  1. The enhanced thermoelectric properties of BiMnO3 ceramics by Sr-doped

    Science.gov (United States)

    Yu, X. Y.; Wang, Y.; Peng, J. J.; Wang, B. L.; Wei, K. L.; Liu, J. M.; He, Q. Y.

    2018-04-01

    A series of Bi1‑xSrxMnO3 (x = 0.40, 0.45, 0.50, 0.55) samples labeled as BSMO040, BSMO045, BSMO050, and BSMO055, respectively, have been fabricated by the modified solid-state reaction method. The crystal structural, microstructures, and chemical states of the elements and the thermoelectric properties were investigated with respect to the partial substitution of Sr2+ for Bi3+. The samples were characterized by x-ray diffraction (XRD) at 723 K, scanning electron microscopy (SEM), and x-ray photoelectron spectroscopy (XPS). Moreover, their electrical conductivities (σ), Seebeck coefficients (S), and thermal conductivities (κ) were determined. All the samples exhibited orthorhombic structure. The partial substitution of Sr2+ for Bi3+ caused valence shift of some Mn ions from +3 to +4 to maintain electric charge balance. The change in electric charge led to an increase in electron concentration, and thus, the electrical conductivity as well as the absolute value of Seebeck coefficient increased. Consequently, the power factor also increased. The highest power factor (0.3 × 10‑4 Wm‑1 K‑1) was obtained for BSMO055 at 1023 K. Moreover, the highest dimensionless figure-of-merit (ZT) obtained in this study was 0.015 for BSMO055 at 1073 K. It can be concluded that the partial substitution of Sr2+ for Bi3+ in the Bi1‑xSrxMnO3 samples (x = 0.40, 0.45, 0.50, and 0.55) improved the thermoelectric properties effectively.

  2. Anti-restenotic effect of copper-62 liquid-filled balloon in porcine coronary arteries: novel use of a short half-life positron emitter

    International Nuclear Information System (INIS)

    Chan, Rosanna C.; Lacy, Jeffrey L.; Bhargava, Balram; Collins, Sara D.; Cates, Pamela; Cottin, Yves; Kollum, Marc; Yang, Nathan; Haynes, Neal G.; Martin, Christopher S.; Nayak, Nisha; Vodovotz, Yoram; Kim, Han-Soo; Waksman, Ron

    2000-01-01

    Purpose: To determine the efficacy of the use of copper-62, a positron emitter with a half-life of 9.7 minutes, as an intracoronary brachytherapy (IRBT) source in the prevention of neointima formation (NF) following overstretch balloon injury (BI) in the porcine model. Methods and Materials: Sixteen swine were treated after BI to their left anterior descending (LAD), left circumflex (LCX), and/or right coronary artery (RCA). Twelve of the injured arteries received placebo and 10 received 25 Gy, delivered to 0.5 mm from the surface of the treatment balloon filled with liquid 62 Cu. Dosimetry was based on Monte Carlo calculations. Two weeks after treatment, the animals were sacrificed, and the treated coronaries were perfusion-fixed and stained. Intimal area (IA) and medial fracture length (FL) were analyzed by computer-aided histomorphometry. Results: The ( 62 Zn/ 62 Cu) generator, together with a rapid concentration process, was successful in delivering the short-lived 62 Cu at the high concentration required for intravascular brachytherapy (IVBT). The fracture length in the two groups was similar (2.10 ± 0.57; 2.02 ± 0.77; p = NS). Arteries studied showed significant reduction in NF (IA: 0.23 ± 0.47 mm 2 vs. 1.08 ± 0.57 mm 2 ; p 62 Cu as an IVBT source is safe and feasible. All 16 swine tolerated the treatment well with no radiation-induced side effects or symptoms throughout the 2-week period. The isotope delivered the dose necessary to inhibit NF in the porcine coronary BI model

  3. Highly flexible and robust N-doped SiC nanoneedle field emitters

    KAUST Repository

    Chen, Shanliang

    2015-01-23

    Flexible field emission (FE) emitters, whose unique advantages are lightweight and conformable, promise to enable a wide range of technologies, such as roll-up flexible FE displays, e-papers and flexible light-emitting diodes. In this work, we demonstrate for the first time highly flexible SiC field emitters with low turn-on fields and excellent emission stabilities. n-Type SiC nanoneedles with ultra-sharp tips and tailored N-doping levels were synthesized via a catalyst-assisted pyrolysis process on carbon fabrics by controlling the gas mixture and cooling rate. The turn-on field, threshold field and current emission fluctuation of SiC nanoneedle emitters with an N-doping level of 7.58 at.% are 1.11 V μm-1, 1.55 V μm-1 and 8.1%, respectively, suggesting the best overall performance for such flexible field emitters. Furthermore, characterization of the FE properties under repeated bending cycles and different bending states reveal that the SiC field emitters are mechanically and electrically robust with unprecedentedly high flexibility and stabilities. These findings underscore the importance of concurrent morphology and composition controls in nanomaterial synthesis and establish SiC nanoneedles as the most promising candidate for flexible FE applications. © 2015 Nature Publishing Group All rights reserved.

  4. Optimization of oxidation processes to improve crystalline silicon solar cell emitters

    Directory of Open Access Journals (Sweden)

    L. Shen

    2014-02-01

    Full Text Available Control of the oxidation process is one key issue in producing high-quality emitters for crystalline silicon solar cells. In this paper, the oxidation parameters of pre-oxidation time, oxygen concentration during pre-oxidation and pre-deposition and drive-in time were optimized by using orthogonal experiments. By analyzing experimental measurements of short-circuit current, open circuit voltage, series resistance and solar cell efficiency in solar cells with different sheet resistances which were produced by using different diffusion processes, we inferred that an emitter with a sheet resistance of approximately 70 Ω/□ performed best under the existing standard solar cell process. Further investigations were conducted on emitters with sheet resistances of approximately 70 Ω/□ that were obtained from different preparation processes. The results indicate that emitters with surface phosphorus concentrations between 4.96 × 1020 cm−3 and 7.78 × 1020 cm−3 and with junction depths between 0.46 μm and 0.55 μm possessed the best quality. With no extra processing, the final preparation of the crystalline silicon solar cell efficiency can reach 18.41%, which is an increase of 0.4%abs compared to conventional emitters with 50 Ω/□ sheet resistance.

  5. Highly flexible and robust N-doped SiC nanoneedle field emitters

    KAUST Repository

    Chen, Shanliang; Ying, Pengzhan; Wang, Lin; Wei, Guodong; Gao, Fengmei; Zheng, Jinju; Shang, Minhui; Yang, Zuobao; Yang, Weiyou; Wu, Tao

    2015-01-01

    Flexible field emission (FE) emitters, whose unique advantages are lightweight and conformable, promise to enable a wide range of technologies, such as roll-up flexible FE displays, e-papers and flexible light-emitting diodes. In this work, we demonstrate for the first time highly flexible SiC field emitters with low turn-on fields and excellent emission stabilities. n-Type SiC nanoneedles with ultra-sharp tips and tailored N-doping levels were synthesized via a catalyst-assisted pyrolysis process on carbon fabrics by controlling the gas mixture and cooling rate. The turn-on field, threshold field and current emission fluctuation of SiC nanoneedle emitters with an N-doping level of 7.58 at.% are 1.11 V μm-1, 1.55 V μm-1 and 8.1%, respectively, suggesting the best overall performance for such flexible field emitters. Furthermore, characterization of the FE properties under repeated bending cycles and different bending states reveal that the SiC field emitters are mechanically and electrically robust with unprecedentedly high flexibility and stabilities. These findings underscore the importance of concurrent morphology and composition controls in nanomaterial synthesis and establish SiC nanoneedles as the most promising candidate for flexible FE applications. © 2015 Nature Publishing Group All rights reserved.

  6. 45 CFR 213.11 - Notice of hearing or opportunity for hearing.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 2 2010-10-01 2010-10-01 false Notice of hearing or opportunity for hearing. 213.11 Section 213.11 Public Welfare Regulations Relating to Public Welfare OFFICE OF FAMILY ASSISTANCE (ASSISTANCE PROGRAMS), ADMINISTRATION FOR CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES PRACTICE AND PROCEDURE FOR HEARINGS TO STATE...

  7. Investigations on the transverse phase space at a photo injector for minimized emittance

    Energy Technology Data Exchange (ETDEWEB)

    Miltchev, V.

    2006-08-15

    Radio frequency photoinjectors are electron sources able to generate beams of extremely high brightness, which are applicable to linac driven Free Electron Lasers (FEL). Because of the high phase space density, the dynamics of the electron beam is dominated by space charge interactions between the particles. This thesis studies the transverse phase space of space charge dominated electron beams produced by the Photo Injector Test Facility in Zeuthen (PITZ). The operation conditions for minimizing the transverse emittance are studied experimentally, theoretically and in simulations. The influence of the longitudinal profile of the driving UV laser pulse on the transverse emittance is investigated. Emphasis is placed on the experimental study of the emittance as a function of different machine parameters like the laser beam spot size, the amplitude of the focusing magnetic field, the rf phase and the electron bunch charge. First investigations on the thermal emittance for Cs{sub 2}Te photocathodes under rf operating conditions are presented. Measurements of the thermal emittance scaling with the photocathode laser spot size are analyzed. The significance of the applied rf field in the emittance formation process is discussed. (orig.)

  8. Investigations on the transverse phase space at a photo injector for minimized emittance

    International Nuclear Information System (INIS)

    Miltchev, V.

    2006-08-01

    Radio frequency photoinjectors are electron sources able to generate beams of extremely high brightness, which are applicable to linac driven Free Electron Lasers (FEL). Because of the high phase space density, the dynamics of the electron beam is dominated by space charge interactions between the particles. This thesis studies the transverse phase space of space charge dominated electron beams produced by the Photo Injector Test Facility in Zeuthen (PITZ). The operation conditions for minimizing the transverse emittance are studied experimentally, theoretically and in simulations. The influence of the longitudinal profile of the driving UV laser pulse on the transverse emittance is investigated. Emphasis is placed on the experimental study of the emittance as a function of different machine parameters like the laser beam spot size, the amplitude of the focusing magnetic field, the rf phase and the electron bunch charge. First investigations on the thermal emittance for Cs 2 Te photocathodes under rf operating conditions are presented. Measurements of the thermal emittance scaling with the photocathode laser spot size are analyzed. The significance of the applied rf field in the emittance formation process is discussed. (orig.)

  9. Emittance studies of the BNL/SLAC/UCLA 1.6 cell photocathode rf gun

    International Nuclear Information System (INIS)

    Palmer, D.T.; Miller, R.H.; Wang, X.J.

    1997-01-01

    The symmetrized 1.6 cell S-band photocathode gun developed by the BNL/SLAC/UCLA collaboration is in operation at the Brookhaven Accelerator Test Facility (ATF). A novel emittance compensation solenoid magnet has also been designed, built and is in operation at the ATF. These two subsystems form an emittance compensated photoinjector used for beam dynamics, advanced acceleration and free electron laser experiments at the ATF. The highest acceleration field achieved on the copper cathode is 150 MV/m, and the guns normal operating field is 130 MV/m. The maximum rf pulse length is 3 micros. The transverse emittance of the photoelectron beam were measured for various injection parameters. The 1 nC emittance results are presented along with electron bunch length measurements that indicated that at above the 400 pC, space charge bunch lengthening is occurring. The thermal emittance, ε o , of the copper cathode has been measured

  10. Development of MnBi permanent magnet: Neutron diffraction of MnBi powder

    Energy Technology Data Exchange (ETDEWEB)

    Cui, J., E-mail: jun.cui@pnnl.gov; Choi, J. P.; Li, G.; Polikarpov, E.; Darsell, J. [Energy and Environment Directorate, Pacific Northwest National Laboratory, Richland, Washington 99354 (United States); Kramer, M. J.; Zarkevich, N. A.; Wang, L. L.; Johnson, D. D. [Materials Sciences and Engineering Division, Ames Laboratory, Ames, Iowa 50011 (United States); Marinescu, M. [Electron Energy Corporation, Landisville, Pennsylvania 17538 (United States); Huang, Q. Z.; Wu, H. [NIST Center for Neutron Research, National Institute of Standards and Technology, Gaithersburg, Maryland 20899-6102 (United States); Vuong, N. V.; Liu, J. P. [Department of Physics, University of Texas at Arlington, Arlington, Texas 76019 (United States)

    2014-05-07

    MnBi attracts great attention in recent years for its great potential as permanent magnet materials. MnBi phase is difficult to obtain because of the rather drastic peritectic reaction between Mn and Bi. In this paper, we report our effort on synthesizing high purity MnBi compound using conventional powder metallurgical approaches. Neutron diffraction was carried out to investigate the crystal and nuclear structure of the obtained powder. The result shows that the purity of the obtained powder is about 91 wt. % at 300 K, and the magnetic moment of the Mn atom in MnBi lattice is 4.424 and 4.013 μ{sub B} at 50 K and 300 K, respectively.

  11. Development of MnBi permanent magnet: Neutron diffraction of MnBi powder

    Energy Technology Data Exchange (ETDEWEB)

    Cui, J; Choi, JP; Li, G; Polikarpov, E; Darsell, J; Kramer, MJ; Zarkevich, NA; Wang, LL; Johnson, DD; Marinescu, M; Huang, QZ; Wu, H; Vuong, NV; Liu, JP

    2014-05-07

    MnBi attracts great attention in recent years for its great potential as permanent magnet materials. MnBi phase is difficult to obtain because of the rather drastic peritectic reaction between Mn and Bi. In this paper, we report our effort on synthesizing high purity MnBi compound using conventional powder metallurgical approaches. Neutron diffraction was carried out to investigate the crystal and nuclear structure of the obtained powder. The result shows that the purity of the obtained powder is about 91 wt. % at 300 K, and the magnetic moment of the Mn atom in MnBi lattice is 4.424 and 4.013 mu(B) at 50 K and 300 K, respectively. (C) 2014 AIP Publishing LLC.

  12. New Method for Determination of Electrically Inactive Phosphorus in n-type Emitters

    OpenAIRE

    Steyer, Michael; Dastgheib-Shirazi, Amir; Hahn, Giso; Terheiden, Barbara

    2015-01-01

    The precise knowledge of the amount and the location in depth of inactive phosphorus in an n-type emitter is still a challenge. As a new approach, we determine the total amount of phosphorus (P dose) in the emitter stepwise in dependence of etching depth with the characterization tool ICP-OES. A comparison of the data with the electrically active P concentration profile measured by ECV allows to determine in which depths electrically inactive phosphorus is present. For a highly doped emitter,...

  13. Emittance compensation with dynamically optimized photoelectron beam profiles

    Energy Technology Data Exchange (ETDEWEB)

    Rosenzweig, J.B. [Department of Physics and Astronomy, UCLA, 405 Hilgard Avenue, Los Angeles, CA 90095 (United States)]. E-mail: rosen@physics.ucla.edu; Cook, A.M. [Department of Physics and Astronomy, UCLA, 405 Hilgard Avenue, Los Angeles, CA 90095 (United States); England, R.J. [Department of Physics and Astronomy, UCLA, 405 Hilgard Avenue, Los Angeles, CA 90095 (United States); Dunning, M. [Department of Physics and Astronomy, UCLA, 405 Hilgard Avenue, Los Angeles, CA 90095 (United States); Anderson, S.G. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States); Ferrario, Massimo [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionale di Frascati, Via E. Fermi 41, Frascati, Rome (Italy)

    2006-02-01

    Much of the theory and experimentation concerning creation of a high-brightness electron beam from a photocathode, and then applying emittance compensation techniques, assumes that one must strive for a uniform density electron beam, having a cylindrical shape. On the other hand, this shape has large nonlinearities in the space-charge field profiles near the beam's longitudinal extrema. These nonlinearities are known to produce both transverse and longitudinal emittance growth. On the other hand, it has recently been shown by Luiten that by illuminating the cathode with an ultra-short laser pulse of appropriate transverse profile, a uniform density, ellipsoidally shaped bunch is dynamically formed, which then has linear space-charge fields in all dimensions inside of the bunch. We study here this process, and its marriage to the standard emittance compensation scenario that is implemented in most recent photoinjectors. It is seen that the two processes are compatible, with simulations indicating a very high brightness beam can be obtained. The robustness of this scheme to systematic errors is examined. Prospects for experimental tests of this scheme are discussed.

  14. Emittance compensation with dynamically optimized photoelectron beam profiles

    International Nuclear Information System (INIS)

    Rosenzweig, J.B.; Cook, A.M.; England, R.J.; Dunning, M.; Anderson, S.G.; Ferrario, Massimo

    2006-01-01

    Much of the theory and experimentation concerning creation of a high-brightness electron beam from a photocathode, and then applying emittance compensation techniques, assumes that one must strive for a uniform density electron beam, having a cylindrical shape. On the other hand, this shape has large nonlinearities in the space-charge field profiles near the beam's longitudinal extrema. These nonlinearities are known to produce both transverse and longitudinal emittance growth. On the other hand, it has recently been shown by Luiten that by illuminating the cathode with an ultra-short laser pulse of appropriate transverse profile, a uniform density, ellipsoidally shaped bunch is dynamically formed, which then has linear space-charge fields in all dimensions inside of the bunch. We study here this process, and its marriage to the standard emittance compensation scenario that is implemented in most recent photoinjectors. It is seen that the two processes are compatible, with simulations indicating a very high brightness beam can be obtained. The robustness of this scheme to systematic errors is examined. Prospects for experimental tests of this scheme are discussed

  15. Measuring emittances and sigma matrices

    International Nuclear Information System (INIS)

    Rees, J.; Rivkin, L.

    1984-03-01

    The method used for measuring emittance at the SLAC Linac and the linear collider damping ring is described. The basis of the method is derived using one two-by-two matrix to specify the state of the input beam (sigma matrix) and another to describe the lens-drift transport system (R-matrix)

  16. Generation of low-emittance electron beams in electrostatic accelerators for FEL applications

    Science.gov (United States)

    Teng, Chen; Elias, Luis R.

    1995-02-01

    This paper reports results of transverse emittance studies and beam propagation in electrostatic accelerators for free electron laser applications. In particular, we discuss emittance growth analysis of a low current electron beam system consisting of a miniature thermoionic electron gun and a National Electrostatics Accelerator (NEC) tube. The emittance growth phenomenon is discussed in terms of thermal effects in the electron gun cathode and aberrations produced by field gradient changes occurring inside the electron gun and throughout the accelerator tube. A method of reducing aberrations using a magnetic solenoidal field is described. Analysis of electron beam emittance was done with the EGUN code. Beam propagation along the accelerator tube was studied using a cylindrically symmetric beam envelope equation that included beam self-fields and the external accelerator fields which were derived from POISSON simulations.

  17. Generation of low-emittance electron beams in electrostatic accelerators for FEL applications

    International Nuclear Information System (INIS)

    Chen Teng; Central Florida Univ., Orlando, FL; Elias, L.R. R.; Central Florida Univ., Orlando, FL

    1995-01-01

    This paper reports results of transverse emittance studies and beam propagation in electrostatic accelerators for free electron laser applications. In particular, we discuss emittance growth analysis of a low current electron beam system consisting of a miniature thermoionic electron gun and a National Electrostatics Accelerator (NEC) tube. The emittance growth phenomenon is discussed in terms of thermal effects in the electron gun cathode and aberrations produced by field gradient changes occurring inside the electron gun and throughout the accelerator tube. A method of reducing aberrations using a magnetic solenoidal field is described. Analysis of electron beam emittance was done with the EGUN code. Beam propagation along the accelerator tube was studied using a cylindrically symmetric beam envelope equation that included beam self-fields and the external accelerator fields which were derived from POISSON simulations. ((orig.))

  18. Generation of low-emittance electron beams in electrostatic accelerators for FEL applications

    Energy Technology Data Exchange (ETDEWEB)

    Chen Teng [University of Central Florida, Orlando, FL (United States). Center for Research in Electro-Optics and Lasers (CREOL)]|[Central Florida Univ., Orlando, FL (United States). Dept. of Physics; Elias, L.R. R. [University of Central Florida, Orlando, FL (United States). Center for Research in Electro-Optics and Lasers (CREOL)]|[Central Florida Univ., Orlando, FL (United States). Dept. of Physics

    1995-01-30

    This paper reports results of transverse emittance studies and beam propagation in electrostatic accelerators for free electron laser applications. In particular, we discuss emittance growth analysis of a low current electron beam system consisting of a miniature thermoionic electron gun and a National Electrostatics Accelerator (NEC) tube. The emittance growth phenomenon is discussed in terms of thermal effects in the electron gun cathode and aberrations produced by field gradient changes occurring inside the electron gun and throughout the accelerator tube. A method of reducing aberrations using a magnetic solenoidal field is described. Analysis of electron beam emittance was done with the EGUN code. Beam propagation along the accelerator tube was studied using a cylindrically symmetric beam envelope equation that included beam self-fields and the external accelerator fields which were derived from POISSON simulations. ((orig.))

  19. Global EiBI-monopole

    Directory of Open Access Journals (Sweden)

    JIN Xinghua

    2014-04-01

    Full Text Available A global EiBI-monopole problem is studied under EiBI gravitational theory.The equations of global EiBI-monopole are derived in the curved spacetime and the relation between the spacetime metric and auxiliary metric is found.In the case of a very small parameter,an asymptotic form of equations is given.The series solutions of global EiBI-monopole at infinity are found.

  20. Internal emitter limits for iodine, radium and radon daughters

    Energy Technology Data Exchange (ETDEWEB)

    Schlenker, R.A.

    1984-08-15

    This paper identifies some of the issues which arise in the consideration of the derivation of new limits on exposure to internal emitters. Basic and secondary radiation protection limits are discussed. Terms are defined and applied to the limitation of risk from stochastic effects. Non-stochastic data for specific internal emitters (/sup 131/I and the radium isotopes) are presented. Emphasis is placed on the quantitative aspects of the limit setting problem. 65 references, 2 figures, 12 tables.

  1. Transverse emittance measurement at REGAE via a solenoid scan

    Energy Technology Data Exchange (ETDEWEB)

    Hachmann, Max; Mayet, Frank; Gruener, Florian [Institut fuer Experimentalphysik, Universitaet Hamburg (Germany); Floettmann, Klaus [DESY, Hamburg (Germany)

    2013-07-01

    The linear accelerator REGAE at DESY produces short and low charged electron bunches, on the one hand to resolve the excitation transitions of atoms temporally by pump probe electron diffraction experiments and on the other hand to investigate principal mechanisms of laser plasma acceleration. For both cases a high quality electron beam is required which can be identified with a small beam emittance. The current method to measure the transverse beam emittance at REGAE and results are presented.

  2. Quantum emitters coupled to surface plasmons of an nanowire

    DEFF Research Database (Denmark)

    Dzsotjan, David; Sørensen, Anders Søndberg; Fleischhauer, Michael

    2010-01-01

    We investigate a system consisting of a single, as well as two emitters strongly coupled to surface plasmon modes of a nanowire using a Green's function approach. Explicit expressions are derived for the spontaneous decay rate into the plasmon modes and for the atom-plasmon coupling as well......-qubit quantum gate. We also discuss a possible realization of interesting many-body Hamiltonians, such as the spin-boson model, using strong emitter-plasmon coupling. Udgivelsesdato: 27 August...

  3. Internal emitter limits for iodine, radium and radon daughters

    International Nuclear Information System (INIS)

    Schlenker, R.A.

    1984-01-01

    This paper identifies some of the issues which arise in the consideration of the derivation of new limits on exposure to internal emitters. Basic and secondary radiation protection limits are discussed. Terms are defined and applied to the limitation of risk from stochastic effects. Non-stochastic data for specific internal emitters ( 131 I and the radium isotopes) are presented. Emphasis is placed on the quantitative aspects of the limit setting problem. 65 references, 2 figures, 12 tables

  4. Low Emittance Guns for the ILC Polarized Electron Beam

    International Nuclear Information System (INIS)

    Clendenin, J. E.; Brachmann, A.; Ioakeimidi, K.; Kirby, R. E.; Maruyama, T.; Miller, R. H.; Wang, J. W.; Zhou, F.

    2007-01-01

    Polarized electron beams generated by DC guns are routinely available at several accelerators including JLAB, Mainz and SLAC. These guns operate with a cathode bias on the order of -100 kV. To minimize space charge effects, relatively long bunches are generated at the gun and then compressed longitudinally external to the gun just before and during initial acceleration. For linear colliders, this compression is accomplished using a combination of rf bunchers. For the basic design of the International Linear Collider (ILC), a 120 kV DC photocathode gun is used to produce a series of nanosecond bunches that are each compressed by two sub-harmonic bunchers (SHBs) followed by an L-band buncher and capture section. The longitudinal bunching process results in a significantly higher emittance than produced by the gun alone. While high-energy experiments using polarized beams are not generally sensitive to the source emittance, there are several benefits to a lower source emittance including a simpler more efficient injector system and a lower radiation load during transport especially at bends as at the damping ring. For the ILC, the SHBs could be eliminated if the voltage of the gun is raised sufficiently. Simulations using the General Particle Tracer (GPT) package indicate that a cathode bias voltage of ≥200 kV should allow both SHBs to be operated at 433 or even 650 MHz, while ≥500 kV would be required to eliminate the SHBs altogether. Simulations can be used to determine the minimum emittance possible if the injector is designed for a given increased voltage. A possible alternative to the DC gun is an rf gun. Emittance compensation, routinely used with rf guns, is discussed for higher-voltage DC guns

  5. Low Emittance Guns for the ILC Polarized Electron Beam

    International Nuclear Information System (INIS)

    Clendenin, J.E.; Brachmann, A.; Ioakeimidi, K.; Kirby, R.E.; Maruyama, T.; Miller, R.H.; Wang, J.W.; Zhou, F.; SLAC

    2006-01-01

    Polarized electron beams generated by DC guns are routinely available at several accelerators including JLAB, Mainz and SLAC. These guns operate with a cathode bias on the order of -100 kV. To minimize space charge effects, relatively long bunches are generated at the gun and then compressed longitudinally external to the gun just before and during initial acceleration. For linear colliders, this compression is accomplished using a combination of rf bunchers. For the basic design of the International Linear Collider (ILC), a 120 kV DC photocathode gun is used to produce a series of nanosecond bunches that are each compressed by two sub-harmonic bunchers (SHBs) followed by an L-band buncher and capture section. The longitudinal bunching process results in a significantly higher emittance than produced by the gun alone. While high-energy experiments using polarized beams are not generally sensitive to the source emittance, there are several benefits to a lower source emittance including a simpler more efficient injector system and a lower radiation load during transport especially at bends as at the damping ring. For the ILC, the SHBs could be eliminated if the voltage of the gun is raised sufficiently. Simulations using the General Particle Tracer (GPT) package indicate that a cathode bias voltage of (ge)200 kV should allow both SHBs to be operated at 433 or even 650 MHz, while (ge)500 kV would be required to eliminate the SHBs altogether. Simulations can be used to determine the minimum emittance possible if the injector is designed for a given increased voltage. A possible alternative to the DC gun is an rf gun. Emittance compensation, routinely used with rf guns, is discussed for higher-voltage DC guns

  6. 13 CFR 120.213 - What fixed interest rates may a Lender charge?

    Science.gov (United States)

    2010-01-01

    ... Lender charge? 120.213 Section 120.213 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION... have a reasonable fixed interest rate. SBA periodically publishes the maximum allowable rate in the... government determines the interest rate on direct loans. SBA publishes the rate periodically in the Federal...

  7. 24 CFR 213.275 - Nature of the Cooperative Management Housing Insurance Fund.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Nature of the Cooperative Management Housing Insurance Fund. 213.275 Section 213.275 Housing and Urban Development Regulations Relating... Nature of the Cooperative Management Housing Insurance Fund. The Cooperative Management Housing Insurance...

  8. 5 CFR 213.3301 - Positions of a confidential or policy-determining nature.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Positions of a confidential or policy-determining nature. 213.3301 Section 213.3301 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL... or policy-determining nature. (a) Upon specific authorization by OPM, agencies may make appointments...

  9. The synthesis of [2-13C]2-nitropropane at room temperature and at atmospheric pressure

    NARCIS (Netherlands)

    Jacquemijns M; Zomer G

    1990-01-01

    In this report the synthesis of [2-13C]2-nitropropane at room temperature is described. [2-13C]Acetone was converted into the oxime with hydroxy hydrochloridelamine and sodium carbonate. Treatment with hypobromic acid resulted in 2-13C]2-bromo-2-nitropropane. Hydrogenation with sodium borohydride

  10. HER2 specific delivery of methotrexate by dendrimer conjugated anti-HER2 mAb

    International Nuclear Information System (INIS)

    Shukla, Rameshwer; Thomas, Thommey P; Desai, Ankur M; Kotlyar, Alina; Park, Steve J; Baker, James R Jr

    2008-01-01

    Herceptin, a humanized monoclonal antibody that binds to human growth factor receptor-2 (HER2), was covalently attached to a fifth-generation (G5) polyamidoamine dendrimer containing the cytotoxic drug methotrexate. The specific binding and internalization of this conjugate labeled with FITC was clearly demonstrated in cell lines overexpressing HER2 by flow cytometry as well as confocal microscopic analysis. In addition, binding and uptake of antibody conjugated dendrimers was completely blocked by excess non-conjugated herceptin. The dendrimer conjugate was also shown to inhibit the dihydrofolate reductase with similar activity to methotrexate. Co-localization experiments with lysotracker red indicate that antibody conjugate, although internalized efficiently into cells, has an unusually long residence time in the lysosome. Somewhat lower cytotoxicity of the conjugate in comparison to free methotrexate was attributed to the slow release of methotrexate from the conjugate and its long retention in the lysosomal pocket

  11. Emittance growth caused by bends in the Los Alamos free-electron laser energy recovery experiment

    International Nuclear Information System (INIS)

    Carlsten, B.E.

    1987-01-01

    Experimentally transporting the beam from the wiggler to the decelerators in the energy recovery experiment (ERX) at the Los Alamos National Laboratory free-electron laser was more difficult than expected because of the large initial emittance in the beam. This emittance was apparently caused in an early 60 0 achromatic bend. To get this beam through subsequent bends without wall interception, the quadrupole focusing had to be changed from the design amount; as a result, the emittance grew further. This paper discusses various mechanisms for this emittance growth in the 60 0 bend, including effects caused by path changes in the bend resulting from wake-field-induced energy changes of particles in the beam and examines emittance filters, ranging from a simple aperture near a beam crossover to more complicated telescope schemes designed to regain the original emittance before the 60 0 bend

  12. Space-charge driven emittance growth in a 3D mismatched anisotropic beam

    International Nuclear Information System (INIS)

    Qiang, J.; Ryne, R.D.; Hofmann, I.

    2002-01-01

    In this paper we present a 3D simulation study of the emittance growth in a mismatched anisotropic beam. The equipartitioning driven by a 4th order space-charge resonance can be significantly modified by the presence of mismatch oscillation and halo formation. This causes emittance growth in both the longitudinal and transverse directions which could drive the beam even further away from equipartition. The averaged emittance growth per degree freedom follows the upper bound of the 2D free energy limit plus the contributions from equipartitioning

  13. Phenotype abnormality: 213 [Arabidopsis Phenome Database[Archive

    Lifescience Database Archive (English)

    Full Text Available 213 http://metadb.riken.jp/db/SciNetS_ria224i/cria224u1ria224u719i decreased sensitivity toward under influ...ence of brassinosteroid ... decreased sensitivity toward ... brassinosteroid ...

  14. Imaging of HER2/neu-positive BT-474 human breast cancer xenografts in athymic mice using {sup 111}In-trastuzumab (Herceptin) Fab fragments

    Energy Technology Data Exchange (ETDEWEB)

    Tang Ying [Division of Nuclear Medicine, University Health Network, Toronto, Ontario, M5G 2C4 (Canada); Department of Pharmaceutical Sciences, University of Toronto, Toronto, Ontario, M5S 2S2 (Canada); Wang, Judy [Division of Nuclear Medicine, University Health Network, Toronto, Ontario, M5G 2C4 (Canada); Scollard, Deborah A. [Division of Nuclear Medicine, University Health Network, Toronto, Ontario, M5G 2C4 (Canada); Mondal, Hridya [Division of Nuclear Medicine, University Health Network, Toronto, Ontario, M5G 2C4 (Canada); Holloway, Claire [Sunnybrook and Women' s College Health Sciences Center, Toronto, Ontario, M4N 3M5 (Canada); Kahn, Harriette J. [Sunnybrook and Women' s College Health Sciences Center, Toronto, Ontario, M4N 3M5 (Canada); Reilly, Raymond M. [Division of Nuclear Medicine, University Health Network, Toronto, Ontario, M5G 2C4 (Canada) and Department of Pharmaceutical Sciences, University of Toronto, Toronto, Ontario, M5S 2S2 (Canada) and Department of Medical Imaging, University of Toronto, Toronto, Ontario, M5S 3E2 (Canada)]. E-mail: raymond.reilly@utoronto.ca

    2005-01-01

    Trastuzumab (Herceptin) Fab were prepared by digestion of intact IgG with immobilized papain, derivatized with diethylenetriaminepentaacetic acid (DTPA) and radiolabeled with {sup 111}In. The dissociation constant (K{sub d}) for binding of Fab to HER2/neu-positive SK-BR-3 human breast cancer cells was two- to threefold higher than for intact IgG (14-36 vs. 8-14 nM). The binding affinity was not significantly decreased after DTPA derivatization (K{sub d}=47 nM). {sup 111}In-trastuzumab Fab localized specifically in HER2/neu-positive BT-474 human breast cancer xenografts in athymic mice with tumor uptake of 7.8{+-}0.7% injected dose (ID)/g and tumor/blood ratio of 25.2{+-}1.6 at 72 h postinjection compared with 2.7{+-}0.7% ID/g and 7.0{+-}0.9 for {sup 111}In-HuM195 anti-CD33 Fab (significantly different, P<.001). Small (3-5 mm in diameter) BT-474 tumors were imaged with {sup 111}In-trastuzumab Fab as early as 24 h postinjection.

  15. Selección tecnico-economica de emisores Technical and economical selection of emitters

    Directory of Open Access Journals (Sweden)

    Eduardo A. Holzapfel

    2007-12-01

    Full Text Available El presente trabajo tuvo como objetivo estudiar los factores que intervienen en la selección técnico económico de goteros. En el estudio fueron utilizados emisores autocompensados y no autocompensados, considerando a los aspectos técnicos como porcentaje de suelo humedecido, número de emisores por planta y coeficiente de uniformidad y precio y la presión de operación del emisor como aspectos económicos. Los resultados muestran que la presión de operación de los emisores es el factor más importante a considerar en la selección, ya que para valores más bajos de presión de operación se obtuvieron menores valores de costo total anualizado, independiente del tipo de gotero. En general, los goteros no autocompesados presentaron valores de costo anualizado menores, para un rango de presión similar. Finalmente el análisis tecnico-económico en la selección de emisores es un procedimiento importante.The objective of this research was to study the parameters that affect the technical-economical selection of emitters. In the study compensated and non-compensated emitters were used. The technical aspects considered were: percentage of wetted soil, number of emitters per plant and the uniformity coefficient as well as price and operation pressure for economic aspects. The results shows that the operation pressure of emitters is the most important factor to be considered in the selection , with smaller values of pressure giving lower total annual cost, independently of the type of emitter. In general, the non-compensated emitter shows lower annual cost values than for compensated emitters, for a similar range of pressures. Finally the technical-economical analysis in the emitter selection is an important procedure.

  16. Compact Rare Earth Emitter Hollow Cathode

    Science.gov (United States)

    Watkins, Ronald; Goebel, Dan; Hofer, Richard

    2010-01-01

    A compact, high-current, hollow cathode utilizing a lanthanum hexaboride (LaB6) thermionic electron emitter has been developed for use with high-power Hall thrusters and ion thrusters. LaB6 cathodes are being investigated due to their long life, high current capabilities, and less stringent xenon purity and handling requirements compared to conventional barium oxide (BaO) dispenser cathodes. The new cathode features a much smaller diameter than previously developed versions that permit it to be mounted on axis of a Hall thruster ( internally mounted ), as opposed to the conventional side-mount position external to the outer magnetic circuit ("externally mounted"). The cathode has also been reconfigured to be capable of surviving vibrational loads during launch and is designed to solve the significant heater and materials compatibility problems associated with the use of this emitter material. This has been accomplished in a compact design with the capability of high-emission current (10 to 60 A). The compact, high-current design has a keeper diameter that allows the cathode to be mounted on the centerline of a 6- kW Hall thruster, inside the iron core of the inner electromagnetic coil. Although designed for electric propulsion thrusters in spacecraft station- keeping, orbit transfer, and interplanetary applications, the LaB6 cathodes are applicable to the plasma processing industry in applications such as optical coatings and semiconductor processing where reactive gases are used. Where current electrical propulsion thrusters with BaO emitters have limited life and need extremely clean propellant feed systems at a significant cost, these LaB6 cathodes can run on the crudest-grade xenon propellant available without impact. Moreover, in a laboratory environment, LaB6 cathodes reduce testing costs because they do not require extended conditioning periods under hard vacuum. Alternative rare earth emitters, such as cerium hexaboride (CeB6) can be used in this

  17. Source brightness and useful beam current of carbon nanotubes and other very small emitters

    International Nuclear Information System (INIS)

    Kruit, P.; Bezuijen, M.; Barth, J.E.

    2006-01-01

    The potential application of carbon nanotubes as electron sources in electron microscopes is analyzed. The resolution and probe current that can be obtained from a carbon nanotube emitter in a low-voltage scanning electron microscope are calculated and compared to the state of the art using Schottky electron sources. Many analytical equations for probe-size versus probe-current relations in different parameter regimes are obtained. It is shown that for most carbon nanotube emitters, the gun lens aberrations are larger than the emitters' virtual source size and thus restrict the microscope's performance. The result is that the advantages of the higher brightness of nanotube emitters are limited unless the angular emission current is increased over present day values or the gun lens aberrations are decreased. For some nanotubes with a closed cap, it is known that the emitted electron beam is coherent over the full emission cone. We argue that for such emitters the parameter ''brightness'' becomes meaningless. The influence of phase variations in the electron wave front emitted from such a nanotube emitter on the focusing of the electron beam is analyzed

  18. A Program to Generate a Particle Distribution from Emittance Measurements

    CERN Document Server

    Bouma, DS; Lallement, JB

    2010-01-01

    We have written a program to generate a particle distribution based on emittance measurements in x-x’ and y-y’. The accuracy of this program has been tested using real and constructed emittance measurements. Based on these tests, the distribution generated by the program can be used to accurately simulate the beam in multi-particle tracking codes, as an alternative to a Gaussian or uniform distribution.

  19. Experimental Study of Coherent Synchrotron Radiation in the Emittance Exchange Line at the A0-Photoinjector

    Science.gov (United States)

    Thangaraj, Jayakar C. T.; Thurman-Keup, R.; Johnson, A.; Lumpkin, A. H.; Edwards, H.; Ruan, J.; Santucci, J.; Sun, Y. E.; Church, M.; Piot, P.

    2010-11-01

    Next generation accelerators will require a high current, low emittance beam with a low energy spread. Such accelerators will employ advanced beam conditioning systems such as emittance exchangers to manipulate high brightness beams. One of the goals of the Fermilab A0 photoinjector is to investigate the transverse to longitudinal emittance exchange principle. Coherent synchrotron radiation could limit high current operation of the emittance exchanger. In this paper, we report on the preliminary experimental and simulation study of the coherent synchroton radiation (CSR) in the emittance exchange line at the A0 photoinjector.

  20. Plexciton quenching by resonant electron transfer from quantum emitter to metallic nanoantenna.

    Science.gov (United States)

    Marinica, D C; Lourenço-Martins, H; Aizpurua, J; Borisov, A G

    2013-01-01

    Coupling molecular excitons and localized surface plasmons in hybrid nanostructures leads to appealing, tunable optical properties. In this respect, the knowledge about the excitation dynamics of a quantum emitter close to a plasmonic nanoantenna is of importance from fundamental and practical points of view. We address here the effect of the excited electron tunneling from the emitter into a metallic nanoparticle(s) in the optical response. When close to a plasmonic nanoparticle, the excited state localized on a quantum emitter becomes short-lived because of the electronic coupling with metal conduction band states. We show that as a consequence, the characteristic features associated with the quantum emitter disappear from the optical absorption spectrum. Thus, for the hybrid nanostructure studied here and comprising quantum emitter in the narrow gap of a plasmonic dimer nanoantenna, the quantum tunneling might quench the plexcitonic states. Under certain conditions the optical response of the system approaches that of the individual plasmonic dimer. Excitation decay via resonant electron transfer can play an important role in many situations of interest such as in surface-enhanced spectroscopies, photovoltaics, catalysis, or quantum information, among others.

  1. Polarization measurements made on LFRA and OASIS emitter arrays

    Science.gov (United States)

    Geske, Jon; Sparkman, Kevin; Oleson, Jim; Laveigne, Joe; Sieglinger, Breck; Marlow, Steve; Lowry, Heard; Burns, James

    2008-04-01

    Polarization is increasingly being considered as a method of discrimination in passive sensing applications. In this paper the degree of polarization of the thermal emission from the emitter arrays of two new Santa Barbara Infrared (SBIR) micro-bolometer resistor array scene projectors was characterized at ambient temperature and at 77 K. The emitter arrays characterized were from the Large Format Resistive Array (LFRA) and the Optimized Arrays for Space-Background Infrared Simulation (OASIS) scene projectors. This paper reports the results of this testing.

  2. High photocatalytic performance of BiOI/Bi{sub 2}WO{sub 6} toward toluene and Reactive Brilliant Red

    Energy Technology Data Exchange (ETDEWEB)

    Li Huiquan [School of Chemistry and Chemical Engineering, Fuyang Normal College, Fuyang 236041 (China); Key Laboratory of Mesoscopic Chemistry of MOE, Jiangsu Provincial Key Laboratory of Nanotechnology, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093 (China); Cui Yumin, E-mail: cuiyumin0908@163.com [School of Chemistry and Chemical Engineering, Fuyang Normal College, Fuyang 236041 (China); Hong Wenshan [School of Chemistry and Chemical Engineering, Fuyang Normal College, Fuyang 236041 (China)

    2013-01-01

    Graphical abstract: When BiOI/Bi{sub 2}WO{sub 6} catalyst was exposed to UV or visible light, the electrons in the valence band of Bi{sub 2}WO{sub 6} would be excited into the conduction band and then injected into the more positive conduction band of BiOI. Therefore, the photoelectrons were generated from Bi{sub 2}WO{sub 6} and transferred across the interface between BiOI and Bi{sub 2}WO{sub 6} to the surface of BiOI, leaving the photogenerated holes in the valence band of Bi{sub 2}WO{sub 6}. In this way, the photoinduced electron-hole pairs were effectively separated. Highlights: Black-Right-Pointing-Pointer BiOI sensitized Bi{sub 2}WO{sub 6} catalysts were successfully prepared by a facile method. Black-Right-Pointing-Pointer The 13.2% BiOI/Bi{sub 2}WO{sub 6} catalyst exhibits higher photoactivities than P25. Black-Right-Pointing-Pointer A possible transfer process of photogenerated carriers was proposed. - Abstract: BiOI sensitized nano-Bi{sub 2}WO{sub 6} photocatalysts with different BiOI contents were successfully synthesized by a facile deposition method at room temperature, and characterized by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) high-resolution transmission electron microscopy (HR-TEM), photoluminescence (PL) spectra, UV-vis diffuse reflection spectroscopy (UV-vis DRS) and Brunauer-Emmett-Teller (BET) surface area measurements. The photocatalytic activity of BiOI/Bi{sub 2}WO{sub 6} was evaluated by the photo-degradation of Reactive Brilliant Red (X-3B) in suspended solution and toluene in gas phase. It has been shown that the BiOI/Bi{sub 2}WO{sub 6} catalysts exhibit a coexistence of both tetragonal BiOI and orthorhombic Bi{sub 2}WO{sub 6} phases. With increasing BiOI content, the absorption intensity of BiOI/Bi{sub 2}WO{sub 6} catalysts increases in the 380-600 nm region and the absorption edge shifts significantly to longer wavelengths as compared to pure Bi{sub 2}WO{sub 6}. The 13.2% BiOI/Bi{sub 2}WO{sub 6} catalyst exhibits

  3. Emittance studies of the 2.45 GHz permanent magnet ECR ion source

    Science.gov (United States)

    Zelenak, A.; Bogomolov, S. L.; Yazvitsky, N. Yu.

    2004-05-01

    During the past several years different types of permanent magnet 2.45 GHz (electron cyclotron resonance) ion sources were developed for production of singly charged ions. Ion sources of this type are used in the first stage of DRIBs project, and are planned to be used in the MASHA mass separator. The emittance of the beam provided by the source is one of the important parameters for these applications. An emittance scanner composed from a set of parallel slits and rotary wire beam profile monitor was used for the studying of the beam emittance characteristics. The emittance of helium and argon ion beams was measured with different shapes of the plasma electrode for several ion source parameters: microwave power, source potential, plasma aperture-puller aperture gap distance, gas pressure. The results of measurements are compared with previous simulations of ion optics.

  4. Emittance studies of the 2.45 GHz permanent magnet ECR ion source

    International Nuclear Information System (INIS)

    Zelenak, A.; Bogomolov, S.L.; Yazvitsky, N.Yu.

    2004-01-01

    During the past several years different types of permanent magnet 2.45 GHz (electron cyclotron resonance) ion sources were developed for production of singly charged ions. Ion sources of this type are used in the first stage of DRIBs project, and are planned to be used in the MASHA mass separator. The emittance of the beam provided by the source is one of the important parameters for these applications. An emittance scanner composed from a set of parallel slits and rotary wire beam profile monitor was used for the studying of the beam emittance characteristics. The emittance of helium and argon ion beams was measured with different shapes of the plasma electrode for several ion source parameters: microwave power, source potential, plasma aperture-puller aperture gap distance, gas pressure. The results of measurements are compared with previous simulations of ion optics

  5. MLED_BI: a new BI Design Approach to Support Multilingualism in Business Intelligence

    Directory of Open Access Journals (Sweden)

    Nedim Dedić

    2017-11-01

    Full Text Available Existing approaches to support Multilingualism (ML in Business Intelligence (BI create problems for business users, present a number of challenges from the technical perspective, and lead to issues with logical dependence in the star schema. In this paper, we propose MLED_BI (Multilingual Enabled Design for Business Intelligence, a novel BI design approach to support the application of ML in BI Environment, which overcomes the issues and problems found with existing approaches. The approach is based on a revision of the data warehouse dimensional modelling approach and treats the Star Schema as a higher level entity. This paper describes MLED_BI and the validation and evaluation approach used.

  6. Ga-Bi-Te system

    International Nuclear Information System (INIS)

    Rustamov, P.G.; Seidova, N.A.; Shakhbazov, M.G.; AN Azerbajdzhanskoj SSR, Baku. Inst. Neorganicheskoj i Fizicheskoj Khimii)

    1976-01-01

    To elucidate the nature of interaction in the system Ga-Bi-Te, a study has been made of sections GaTe-Bi 2 Te 3 , Ga 2 Te 3 -Bi, GaTe-Bi and Bi 2 Te 3 -Ga. The alloys have been prepared by direct melting of the components or their alloys with subsequent homogenizin.o annealing at 400 deg C. The study has been made by the methods of differential thermal, microstructural analysis and by microhardness measurements. On the basis of literature data and data obtained a projection of the liquidus surface of the phase diagram for the system Ga-Bi-Te has been constructed. In the ternary system there are 17 curves of monovariant equilibrium dividing the liquidus into 10 fields of primary crystallization of phases, 9 points of non-variant equilibrium of which 4 points are triple eutectics and 5 points are triple peritectics

  7. Emittance measuring system on the UNILAC

    International Nuclear Information System (INIS)

    Ehrich, A.; Glatz, J.; Strahl, P.

    A description is given of one of the beam emittance measuring systems designed for the UNILAC at GSI. The measuring system mechanics and the detector system are detailed, and the associated electronics are discussed. Computer programming and data processing and evaluation are described

  8. Simple emittance measurement of negative hydrogen ion beam using pepper-pot method

    International Nuclear Information System (INIS)

    Hamabe, M.; Tsumori, K.; Takeiri, Y.; Kaneko, O.; Asano, E.; Kawamoto, T.; Kuroda, T.; Guharay, S.K.

    1997-01-01

    A simple apparatus for emittance measurement using pepper-pot method is developed. The pepper-pot patterns are directly exposed and recorded on a Kapton foil. Using this apparatus, emittance was measured in the case of the negative hydrogen (H - ) beam from the large negative ion source, which is the 1/3 scaled test device for the negative-ion-based neutral beam injection (N-NBI) on the Large Helical Device (LHD). As the consequence of the first trial, the 95% normalized emittance value is measured as 0.59 mm mrad. (author)

  9. Simple emittance measurement of negative hydrogen ion beam using pepper-pot method

    Energy Technology Data Exchange (ETDEWEB)

    Hamabe, M.; Tsumori, K.; Takeiri, Y.; Kaneko, O.; Asano, E.; Kawamoto, T.; Kuroda, T. [National Inst. for Fusion Science, Nagoya (Japan); Guharay, S.K.

    1997-02-01

    A simple apparatus for emittance measurement using pepper-pot method is developed. The pepper-pot patterns are directly exposed and recorded on a Kapton foil. Using this apparatus, emittance was measured in the case of the negative hydrogen (H{sup -}) beam from the large negative ion source, which is the 1/3 scaled test device for the negative-ion-based neutral beam injection (N-NBI) on the Large Helical Device (LHD). As the consequence of the first trial, the 95% normalized emittance value is measured as 0.59 mm mrad. (author)

  10. Effects of emittance and space-charge in femtosecond bunch compression

    International Nuclear Information System (INIS)

    Kan, K.; Yang, J.; Kondoh, T.; Norizawa, K.; Yoshida, Y.

    2008-01-01

    Ultrashort electron bunches of the order of <100fs are essential for the study of ultrafast reactions and phenomena by means of time-resolved pump-probe experiments. In order to generate such an electron bunch, the effects of emittance, space-charge (SC) and coherent synchrotron radiation (CSR) on the bunch length in a femtosecond magnetic bunch compressor were studied theoretically. It was observed that the bunch length is dominated by the emittance, SC and CSR effects when the electron bunch is compressed into a femtosecond electron bunch. The increases in bunch length due to the transverse emittance, SC and CSR effects in the bunch compressor were 1.7 fs/mm mrad, 107 fs/nC and 72 fs/nC, respectively. Finally, the simulated bunch length was compared with the experimental results.

  11. Emittance growth in coast in the SPS

    CERN Document Server

    Alekou, A; Bartosik, H; Calaga, R

    2017-01-01

    The CERN SPS will be used as a test-bed for the LHCprototype crab-cavities, which will be installed and testedin the SPS in 2018. As the time available for experimen-tal beam dynamics studies with the crab cavities installedin the machine will be limited, a very good preparation isrequired in advance. One of the main concerns is the in-duced emittance growth, driven by phase jitter in the crabcavities. In this respect, several machine development (MD)studies were performed during the past years to quantifyand characterize the emittance evolution of proton beamsin coast in the SPS. In these proceedings, the experimentalobservations from past years are summarized and the MDstudies from 2016 are presented. Finally, a proposal for anexperimental program for 2017 is discussed.

  12. Decoupling Intensity Radiated by the Emitter in Distance Estimation from Camera to IR Emitter

    Directory of Open Access Journals (Sweden)

    Carlos Andrés Luna Vázquez

    2013-05-01

    Full Text Available Various models using radiometric approach have been proposed to solve the problem of estimating the distance between a camera and an infrared emitter diode (IRED. They depend directly on the radiant intensity of the emitter, set by the IRED bias current. As is known, this current presents a drift with temperature, which will be transferred to the distance estimation method. This paper proposes an alternative approach to remove temperature drift in the distance estimation method by eliminating the dependence on radiant intensity. The main aim was to use the relative accumulated energy together with other defined models, such as the zeroth-frequency component of the FFT of the IRED image and the standard deviation of pixel gray level intensities in the region of interest containing the IRED image. By using the abovementioned models, an expression free of IRED radiant intensity was obtained. Furthermore, the final model permitted simultaneous estimation of the distance between the IRED and the camera and the IRED orientation angle. The alternative presented in this paper gave a 3% maximum relative error over a range of distances up to 3 m.

  13. Transverse and longitudinal emittance measurements in the ELSA linac

    International Nuclear Information System (INIS)

    Loulergue, A.; Dowell, D.H.; Joly, S.; De Brion, J.P.; Haouat, G.; Schumann, F.

    1997-01-01

    The ELSA RF linac photoinjector has been designed to deliver high-brightness electron beams. The present paper deals with the transverse and longitudinal emittance measurements, at different locations along the ELSA beam line, and the analysis of their variations as a function of the photoinjector parameters : magnetic field generated by the anode focusing lens, bunch charge and pulse duration. While transverse emittance has been already studied in other similar installations, there has been little study of the electron beam longitudinal dynamics. Experimental results are presented and compared to simulation-code expectations. For 2.0 nC, 85 A electron bunches, a normalized rms emittance of 2 π mm mrad and a brightness of 4.5 x 10 13 A/(π m rad) 2 at the linac exit have been measured as well as less than 10 keV rms energy spread (or less than 0.1% at 16.5 MeV). (orig.)

  14. 7 CFR 1220.213 - Establishment and membership.

    Science.gov (United States)

    2010-01-01

    ....213 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING... of the Secretary, a Soybean Program Coordinating Committee to assist in the administration of this... soybean production. (c) Cooperator Organization representation on the Committee shall consist of five...

  15. Auger electron emitter against multiple myeloma - targeted endo-radio-therapy with 125I-labeled thymidine analogue 5-iodo-4'-thio-2'-deoxyuridine

    International Nuclear Information System (INIS)

    Morgenroth, Agnieszka; Dinger, Cornelia; Zlatopolskiy, Boris D.; Al-Momani, Ehab; Glatting, Gerhard; Mottaghy, Felix M.; Reske, Sven N.

    2011-01-01

    Introduction: Multiple myeloma (MM) is a plasma cell malignancy characterized by accumulation of malignant, terminally differentiated B cells in the bone marrow. Despite advances in therapy, MM remains an incurable disease. Novel therapeutic approaches are, therefore, urgently needed. Auger electron-emitting radiopharmaceuticals are attractive for targeted nano-irradiation therapy, given that DNA of malignant cells is selectively addressed. Here we evaluated the antimyeloma potential of the Auger electron-emitting thymidine analogue 125 I-labeled 5-iodo-4'-thio-2'-deoxyuridine ([ 125 I]ITdU). Methods: Cellular uptake and DNA incorporation of [ 125 I]ITdU were determined in fluorodeoxyuridine-pretreated KMS12BM, U266, dexamethasone-sensitive MM1.S and -resistant MM1.R cell lines. The effect of stimulation with interleukin 6 (IL6) or insulin-like growth factor 1 (IGF1) on the intracellular incorporation of [ 125 I]ITdU was investigated in cytokine-sensitive MM1.S and MM1.R cell lines. Apoptotic cells were identified using Annexin V. Cleavage of caspase 3 and PARP was visualized by Western blot. DNA fragmentation was investigated using laddering assay. Therapeutic efficiency of [ 125 I]ITdU was proven by clonogenic assay. Results: [ 125 I]ITdU was shown to be efficiently incorporated into DNA of malignant cells, providing a promising mechanism for delivering highly toxic Auger radiation emitters into tumor DNA. [ 125 I]ITdU had a potent antimyeloma effect in cell lines representing distinct disease stages and, importantly, in cell lines sensitive or resistant to the conventional therapeutic agent, but was not toxic for normal plasma and bone marrow stromal cells. Furthermore, [ 125 I]ITdU abrogated the protective actions of IL6 and IGF1 on MM cells. [ 125 I]ITdU induced massive damage in the DNA of malignant plasma cells, which resulted in efficient inhibition of clonogenic growth. Conclusion: These studies may provide a novel treatment strategy for overcoming

  16. The radiolabeled monoclonal antibodies in immunoscintigraphy and radioimmunotherapy: current state and perspectives

    International Nuclear Information System (INIS)

    Chatal, J. F.

    2000-01-01

    The antibodies can be satisfactorily labelled with technitium-99 m or indium-111 for tumor immunoscintigraphy. The immunoscintigraphy is not useful for the primary tumor diagnosis. It can be useful for the diagnosis of the some cancer extension and for recurrent tumor visualization. The immunoscintigraphy is widely competed with Positron Emission Tomography (PET) which gives accurate results. In the future the immunoscintigraphy, in pre-therapeutic stage, contribute to the estimation of the dose delivered to the tumor and to normal organs for adopting or not a radioimmunotherapy. The antibodies can also be labeled with Iodine-131 for an application in radioimmunotherapy (RIT). The RIT is efficient in the non-Hodgkin's lymphoma treatment because of their great radiosensitivity. Until now the results have been very modest in solid tumor treatment but methodological and biotechnological progresses have to improve the efficiency especially for the small tumors. In the future iodine-131 which requires the confinement (very expensive) of patients will be substituted by yttrium-90 beta emitter, more energetic than iodine-131 and can be injected in walking case. In the long term, the alpha emitter radionuclides (astatine-211 or bismuth-213) can be used for hematologic cancer treatment. In conclusion the future of radiolabeled monoclonal antibodies is essentially therapeutic. The radioimmunotherapy associated to the chemotherapy give promising perspectives for the radiosensitive cancer treatment and in general small solid tumor treatment (F.M.)

  17. Electronic structures and stability of Ni/Bi2Te3 and Co/Bi2Te3 interfaces

    International Nuclear Information System (INIS)

    Xiong Ka; Wang Weichao; Alshareef, Husam N; Gupta, Rahul P; Gnade, Bruce E; Cho, Kyeongjae; White, John B

    2010-01-01

    We investigate the electronic structures and stability for Ni/Bi 2 Te 3 , NiTe/Bi 2 Te 3 , Co/Bi 2 Te 3 and CoTe 2 /Bi 2 Te 3 interfaces by first-principles calculations. It is found that the surface termination strongly affects the band alignment. Ni and Co are found to form Ohmic contacts to Bi 2 Te 3 . The interface formation energy for Co/Bi 2 Te 3 interfaces is much lower than that of Ni/Bi 2 Te 3 interfaces. Furthermore, we found that NiTe on Bi 2 Te 3 is more stable than Ni, while the formation energies for Co and CoTe 2 on Bi 2 Te 3 are comparable.

  18. Simple-to-prepare multipoint field emitter

    Science.gov (United States)

    Sominskii, G. G.; Taradaev, E. P.; Tumareva, T. A.; Mishin, M. V.; Kornishin, S. Yu.

    2015-07-01

    We investigate multitip field emitters prepared by electroerosion treatment of the surface of molybdenum samples. Their characteristics are determined for operation with a protecting activated fullerene coating. Our experiments indicate that such cathodes are promising for high-voltage electron devices operating in technical vacuum.

  19. Characterization of microstructured fibre emitters: in pursuit of improved nano electrospray ionization performance.

    Science.gov (United States)

    Wu, Xinyun; Oleschuk, Richard D; Cann, Natalie M

    2012-09-21

    Full-dimensional computational fluid dynamics (CFD) simulations are presented for nano electrospray ionization (ESI) with various emitter designs. Our CFD electrohydrodynamic simulations are based on the Taylor-Melcher leaky-dielectric model, and the volume of fluid technique for tracking the fast-changing liquid-gas interface. The numerical method is first validated for a conventional 20 μm inner diameter capillary emitter. The impact of ESI voltage, flow rate, emitter tapering, surface hydrophobicity, and fluid conductivity on the nano-ESI behavior are thoroughly investigated and compared with experiments. Multi-electrospray is further simulated with 2-hole and 3-hole emitters with the latter having a linear or triangular hole arrangement. The simulations predict multi-electrospray behavior in good agreement with laboratory observations.

  20. Study of in vivo generators Pb-212/Bi--212 and U-230/Th-226 for alpha radioimmunotherapy

    International Nuclear Information System (INIS)

    Le Du, A.

    2011-01-01

    Alpha-radioimmunotherapy is a promising cancer therapy that uses a-particles vectorized by monoclonal antibody to break down cancerous tumors. The notion of in vivo generator was introduced in 1989 by Leonard Mausner. The concept involves labeling of various molecular carriers (antibodies, peptides, etc) with intermediate half-life generator parents, which after accumulation in the desired tissue generate much shorter half-life daughter radionuclide. This thesis focuses on the study of two in vivo generators potentially interesting for alpha-radioimmunotherapy: Pb-212 / Bi-212 generator and U-230 / Th-226 generator. The first part of this work presents the Pb-212 / Bi-212 generator, two approaches allowing the vectorization. Chelation approach on a protein and an approach by encapsulation in liposomes have been proposed. This last approach appears to be the most interesting. In vitro stability studies have been performed on these labeling. The second part of this work presents the U-230 / Th-226 generator. Studies have first been made to achieve a theoretical model to describe the speciation of Th(IV) in human serum. The efficacy of DTPA as chelating agent for complexation of Th(IV) in human serum could thus be estimated. (author)