WorldWideScience

Sample records for emittance compensation studies

  1. Criteria for emittance compensation in high-brightness photoinjectors

    Directory of Open Access Journals (Sweden)

    Chun-xi Wang

    2007-10-01

    Full Text Available A critical process in high-brightness photoinjectors is emittance compensation, which brings under control the correlated transverse emittance growth due to the linear space-charge force. Although emittance compensation has been used and studied for almost two decades, the exact criteria to achieve emittance compensation is not as clear as it should be. In this paper, a perturbative analysis of slice envelopes and emittance evolution close to any reference envelope is developed, via which space-charge and chromatic effects are investigated. A new criterion for emittance compensation is found, which is complementary to the well-known matching condition for the invariant envelope and agrees very well with simulations.

  2. Emittance compensation of CW DC-gun photoinjector

    International Nuclear Information System (INIS)

    Li Peng; Wu Dai; Xu Zhou; Li Ming; Yang Xingfan

    2011-01-01

    Emittance growth induced by space charge effect is very important, especially for CW DC-gun photoinjector. In this work, the linear space charge force and its effect on electron beam transverse emittance are studied, and the principle and properties of emittance compensation by solenoid are analyzed. The CAEP DC-gun photoinjector with a solenoid is also simulated by code Parmela. Simulated results indicate that the normalized transverse emittance of an 80 pC bunch at the 350 keV DC-gun ex-it is 5.14 mm · mrad. And after compensated by a solenoid, it becomes 1.27 mm · mrad. The emittance of beam is well compensated. (authors)

  3. Analysis of emittance compensation and simulation results to photo-cathode RF gun

    CERN Document Server

    LiuShengGuang

    2002-01-01

    The emittance compensation technology will be used on the photo-cathode RF gun for Shanghai SDUV-FEL. The space charge force and its effect on electron beam transverse emittance in RF gun is studied, the principle of emittance compensation in phase-space is discussed. The authors have designed a compensation solenoid and calculated its magnetic field distribution. Its performance has been studied by the code PARMELA. A simulation result indicates that the normalized transverse RMS emittance for electron beam of 1.5 nC is 1.612 pi mm centre dot mrad, electron energy E = 5.71 MeV

  4. Emittance compensation with dynamically optimized photoelectron beam profiles

    Energy Technology Data Exchange (ETDEWEB)

    Rosenzweig, J.B. [Department of Physics and Astronomy, UCLA, 405 Hilgard Avenue, Los Angeles, CA 90095 (United States)]. E-mail: rosen@physics.ucla.edu; Cook, A.M. [Department of Physics and Astronomy, UCLA, 405 Hilgard Avenue, Los Angeles, CA 90095 (United States); England, R.J. [Department of Physics and Astronomy, UCLA, 405 Hilgard Avenue, Los Angeles, CA 90095 (United States); Dunning, M. [Department of Physics and Astronomy, UCLA, 405 Hilgard Avenue, Los Angeles, CA 90095 (United States); Anderson, S.G. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States); Ferrario, Massimo [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionale di Frascati, Via E. Fermi 41, Frascati, Rome (Italy)

    2006-02-01

    Much of the theory and experimentation concerning creation of a high-brightness electron beam from a photocathode, and then applying emittance compensation techniques, assumes that one must strive for a uniform density electron beam, having a cylindrical shape. On the other hand, this shape has large nonlinearities in the space-charge field profiles near the beam's longitudinal extrema. These nonlinearities are known to produce both transverse and longitudinal emittance growth. On the other hand, it has recently been shown by Luiten that by illuminating the cathode with an ultra-short laser pulse of appropriate transverse profile, a uniform density, ellipsoidally shaped bunch is dynamically formed, which then has linear space-charge fields in all dimensions inside of the bunch. We study here this process, and its marriage to the standard emittance compensation scenario that is implemented in most recent photoinjectors. It is seen that the two processes are compatible, with simulations indicating a very high brightness beam can be obtained. The robustness of this scheme to systematic errors is examined. Prospects for experimental tests of this scheme are discussed.

  5. Emittance compensation with dynamically optimized photoelectron beam profiles

    International Nuclear Information System (INIS)

    Rosenzweig, J.B.; Cook, A.M.; England, R.J.; Dunning, M.; Anderson, S.G.; Ferrario, Massimo

    2006-01-01

    Much of the theory and experimentation concerning creation of a high-brightness electron beam from a photocathode, and then applying emittance compensation techniques, assumes that one must strive for a uniform density electron beam, having a cylindrical shape. On the other hand, this shape has large nonlinearities in the space-charge field profiles near the beam's longitudinal extrema. These nonlinearities are known to produce both transverse and longitudinal emittance growth. On the other hand, it has recently been shown by Luiten that by illuminating the cathode with an ultra-short laser pulse of appropriate transverse profile, a uniform density, ellipsoidally shaped bunch is dynamically formed, which then has linear space-charge fields in all dimensions inside of the bunch. We study here this process, and its marriage to the standard emittance compensation scenario that is implemented in most recent photoinjectors. It is seen that the two processes are compatible, with simulations indicating a very high brightness beam can be obtained. The robustness of this scheme to systematic errors is examined. Prospects for experimental tests of this scheme are discussed

  6. Emittance growth due to space charge compensation and beam intensity instabilities in negative ion beams

    Directory of Open Access Journals (Sweden)

    C. A. Valerio-Lizarraga

    2018-03-01

    Full Text Available The need to extract the maximum beam intensity with low transversal emittance often comes with the drawback of operating the ion source to limits where beam current instabilities arise, such fluctuations can change the beam properties producing a mismatch in the following sections of the machine. The space charge compensation (SCC generated by the beam particles colliding with the residual gas reaches a steady state after a build-up time. This paper shows how once in the steady state, the beam ends with a transversal emittance value bigger than the case without compensation. In addition, we study how the beam intensity variation can disturb the SCC dynamics and its impact on the beam properties. The results presented in this work come from 3-D simulations using tracking codes taking into account the secondary ions to estimate the degree of the emittance growth due to space charge and SCC.

  7. Nonlinear electrostatic emittance compensation in kA, fs electron bunches

    International Nuclear Information System (INIS)

    Geer, S.B. van der; Loos, M.J. de; Botman, J.I.M.; Luiten, O.J.; Wiel, M.J. van der

    2002-01-01

    Nonlinear space-charge effects play an important role in emittance growth in the production of kA electron bunches with a bunch length much smaller than the bunch diameter. We propose a scheme employing the radial third-order component of an electrostatic acceleration field, to fully compensate the nonlinear space-charge effects. This results in minimal transverse root-mean-square emittance. The principle is demonstrated using our design simulations of a device for the production of high-quality, high-current, subpicosecond electron bunches using electrostatic acceleration in a 1 GV/m field. Simulations using the GPT code produce a bunch of 100 pC and 73 fs full width at half maximum pulse width, resulting in a peak current of about 1.2 kA at an energy of 2 MeV. The compensation scheme reduces the root-mean-square emittance by 34% to 0.4π mm mrad

  8. Hydraulic performance evaluation of pressure compensating (pc) emitters and micro-tubing for drip irrigation system

    International Nuclear Information System (INIS)

    Mangrio, A.G.; Asif, M.; Jahangir, I.

    2013-01-01

    Drip irrigation system is necessary for those areas, where the water scarcity issues are present. The present study was conducted at the field station of Climate Change, Alternate Energy and Water Resources Institute (CAEWRI), National Agricultural Research Center (NARC), Islamabad, during 2013, regarding drip irrigation system. Drip irrigation system depends on uniform emitter application flow. All the emitters were tested and replicated thrice at pressure head (34 to 207Kpa) with an increment of 34 Kpa. The minimum and maximum discharges were 1.32 - 3.52, 3.36 - 5.42, and 43.22 - 100.99 Lph, with an average of 2.42, 4.63 and 73.66 Lph, for Bow Smith, RIS and Micro-tubing, respectively. It indicates that more than 90% of emission uniformity (EU) and uniformity coefficient (CU) for all Emitters, which shows excellent water application with least standard deviation, ranging 0.12 to 2.37, throughout the operating pressure heads in all emitters. An average coefficient of variation (CV) of all emitters were behaving less than 0.07, indicating an excellent class at all operating pressure heads between 34 to 207 Kpa. Moreover, the relationship of discharge and pressure of emitters indicates that discharge increased with the increase of pressure head. The Q-H curve plays key role in the selection of emitters. (author)

  9. Center for Worker's Compensation Studies

    Data.gov (United States)

    Federal Laboratory Consortium — The mission of the NIOSH Center for Workers’ Compensation Studies (CWCS) is to use workers’ compensation data and systems to improve workplace safety and health....

  10. Simulations of the BNL/SLAC/UCLA 1.6 cell emittance compensated photocathode RF gun low energy beam line

    International Nuclear Information System (INIS)

    Palmer, D.T.; Miller, R.H.; Winick, H.

    1995-01-01

    A dedicated low energy (2 to 10 MeV) experimental beam line is now under construction at Brookhaven National Laboratories Accelerator Test Facility (BNL/ATF) for photocathode RF gun testing and photoemission experiments. The design of the experimental line, using the 1.6 cell photocathode RF gun developed by the BNL/SLAC/UCLA RF gun collaboration is presented. Detailed beam dynamics simulations were performed for the 1.6 cell RF gun injector using a solenoidal emittance compensation technique. An experimental program for testing the 1.6 cell RF gun is presented. This program includes beam loading caused by dark current, higher order mode field measurements, integrated and slice emittance measurements using a pepper-pot and RF kicker cavity

  11. [Vestibular compensation studies]. [Vestibular Compensation and Morphological Studies

    Science.gov (United States)

    Perachio, Adrian A. (Principal Investigator)

    1996-01-01

    The following topics are reported: neurophysiological studies on MVN neurons during vestibular compensation; effects of spinal cord lesions on VNC neurons during compensation; a closed-loop vestibular compensation model for horizontally canal-related MVN neurons; spatiotemporal convergence in VNC neurons; contributions of irregularly firing vestibular afferents to linear and angular VOR's; application to flight studies; metabolic measures in vestibular neurons; immediate early gene expression following vestibular stimulation; morphological studies on primary afferents, central vestibular pathways, vestibular efferent projection to the vestibular end organs, and three-dimensional morphometry and imaging.

  12. Studies of emittance growth in the ATF

    International Nuclear Information System (INIS)

    Zimmermann, F.

    1997-03-01

    Several different mechanisms of emittance growth in the Accelerator Test Facility (ATF) at KEK are investigated: the author calculates rise times of the fast beam-ion instability for the damping ring (DR), and discusses the emittance growth caused by coherent synchrotron radiation in the beam-transport line (BT), the effect of quadrupole wake fields in the injector linac, and, finally, a single-bunch head-tail ion effect that can occur in both the DR and the BT. A first attempt to measure the quadrupole wake on the real machine is also reported

  13. Simulation studies of emittance growth in RMS mismatched beams

    International Nuclear Information System (INIS)

    Cucchetti, A.; Wangler, T.; Reiser, M.

    1991-01-01

    As shown in a separate paper, a charged-particle beam, whose rms size is not matched when injected into a transport channel or accelerator, has excess energy compared with that of a matched beam. If nonlinear space-charge forces are present and the mismatched beam transforms to a matched equilibrium state, rms-emittance growth will occur. The theory yields formulas for the possible rms-emittance growth, but not for the time it takes to achieve this growth. In this paper we present the results of systematic simulation studies for a mismatched 2-D round beam in an ideal transport channel with continuous linear focusing. Emittance growth rates obtained from the simulations for different amounts of mismatch and initial charge will be presented and the emittance growth will be compared with the theory. 6 refs., 7 figs

  14. Low Emittance Tuning Studies for SuperB

    Energy Technology Data Exchange (ETDEWEB)

    Liuzzo, Simone; /INFN, Pisa; Biagini, Maria; /INFN, Rome; Raimondi, Pantaleo; /INFN, Rome; Donald, Martin; /SLAC

    2012-07-06

    SuperB[1] is an international project for an asymmetric 2 rings collider at the B mesons cm energy to be built in the Rome area in Italy. The two rings will have very small beam sizes at the Interaction Point and very small emittances, similar to the Linear Collider Damping Rings ones. In particular, the ultra low vertical emittances, 7 pm in the LER and 4 pm in the HER, need a careful study of the misalignment errors effects on the machine performances. Studies on the closed orbit, vertical dispersion and coupling corrections have been carried out in order to specify the maximum allowed errors and to provide a procedure for emittance tuning. A new tool which combines MADX and Matlab routines has been developed, allowing for both corrections and tuning. Results of these studies are presented.

  15. Emittances Studies at the Fermilab/NICADD Photoinjector Laboratory

    CERN Document Server

    Tikhoplav, Rodion; Melissinos, A C; Regis-Guy Piot, Philippe

    2005-01-01

    The Fermilab/NICADD photoinjector incorporates an L-band rf-gun capable of generating 1-10 nC bunches. The bunches are then accelerated to 16 MeV with a TESLA superconducting cavity. In the present paper we present parametric studies of transverse emittances and energy spread for a various operating points of the electron source (RF-gun E-field, laser length and spot size, and solenoid settings). We especially study the impact, on transverse emittance, of Gaussian and Plateau temporal distribution of the photocathode drive-laser.

  16. Emittance studies of the BNL/SLAC/UCLA 1.6 cell photocathode rf gun

    International Nuclear Information System (INIS)

    Palmer, D.T.; Miller, R.H.; Wang, X.J.

    1997-01-01

    The symmetrized 1.6 cell S-band photocathode gun developed by the BNL/SLAC/UCLA collaboration is in operation at the Brookhaven Accelerator Test Facility (ATF). A novel emittance compensation solenoid magnet has also been designed, built and is in operation at the ATF. These two subsystems form an emittance compensated photoinjector used for beam dynamics, advanced acceleration and free electron laser experiments at the ATF. The highest acceleration field achieved on the copper cathode is 150 MV/m, and the guns normal operating field is 130 MV/m. The maximum rf pulse length is 3 micros. The transverse emittance of the photoelectron beam were measured for various injection parameters. The 1 nC emittance results are presented along with electron bunch length measurements that indicated that at above the 400 pC, space charge bunch lengthening is occurring. The thermal emittance, ε o , of the copper cathode has been measured

  17. Application of positron emitters to studies on plants

    Energy Technology Data Exchange (ETDEWEB)

    Ishioka, N S; Matsuoka, H [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Sekine, T [and others

    1998-10-01

    A newly developed positron emitting tracer imaging system enables us to study dynamically the physiological function of plants, although this system covers, at present, a limited area in a plant. Production of the positron emitters {sup 11}C, {sup 13}N, {sup 18}F and {sup 48}V for this application, using an AVF cyclotron, is described. (author)

  18. Study of beam-beam long range compensation with octupoles

    CERN Document Server

    AUTHOR|(CDS)2068329; Pieloni, Tatiana; Buffat, Xavier; Tambasco, Claudia

    2017-01-01

    Long range beam-beam effects are responsible for particle losses and define fundamental operational parameters of colliders (i.e. crossing angles, intensities, emittances, ${\\beta}$${^∗}$). In this study we propose octuple magnets as a possible scheme to efficiently compensate long-range beam-beam interactions with a global correction scheme. The impact and improvements on the dynamic aperture of colliding beams together with estimates of the luminosity potentials are dis- cussed for the HL-LHC upgrade and extrapolations made for the FCC project.

  19. Monte Carlo Transverse Emittance Study on Cs2Te

    CERN Document Server

    Banfi, F; Galimberti, P G; Giannetti, C; Pagliara, S; Parmigiani, F; Pedersoli, E

    2005-01-01

    A Monte Carlo study of electron transport in Cs2Te films is performed to investigate the transverse emittance epsilon at the cathode surface. We find the photoemitted electron angular distribution and explain the physical mechanism involved in the process, a mechanism hindered by the statistical nature of the Monte Carlo method. The effects of electron-phonon scattering are discussed. The transverse emittance is calculated for different radiation wavelengths and a laser spot size of 1.5*10(-3) m. For a laser radiation at 265 nm we find epsilon = 0.56 mm-mrad. The dependence of epsilon and the quantum yield on the electron affinity Ea is also investigated. The data shows the importance of aging/contamination on the material.

  20. Transverse emittance studies of an induction accelerator of heavy ions

    International Nuclear Information System (INIS)

    Garvey, T.; Eylon, S.; Fessenden, T.J.; Hahn, K.; Henestroza, E.

    1991-01-01

    Current amplification of heavy ion beams is an integral feature of the induction linac approach to heavy ion fusion. As part of the Heavy Ion Fusion Accelerator Research program at LBL the authors have been studying the evolution of the transverse emittance of ion beams while they are undergoing current amplification, achieved by longitudinal bunch compression and acceleration. Experiments are conducted on MBE-4, a four beam Cs + induction linac. The space-charge dominated beams of MBE-4 are focused by electrostatic quadrupoles while they are accelerated from nominally 200 keV up to ∼ 1 MEV by 24 accelerating gaps. Initially the beams have currents of typically 4 mA to 10 mA per beam. Early experimental results showed a growth of the normalized emittance by a factor of 2 while the beam current was amplified by up to 9 times its initial value. The authors will discuss the results of recent experiments in which a mild bunch length compression rate, more typical of that required by a fusion driver, has shown that the normalized emittance can be maintained at its injection value (0.03 mm-mr) during acceleration

  1. Experimental Study of Coherent Synchrotron Radiation in the Emittance Exchange Line at the A0-Photoinjector

    Science.gov (United States)

    Thangaraj, Jayakar C. T.; Thurman-Keup, R.; Johnson, A.; Lumpkin, A. H.; Edwards, H.; Ruan, J.; Santucci, J.; Sun, Y. E.; Church, M.; Piot, P.

    2010-11-01

    Next generation accelerators will require a high current, low emittance beam with a low energy spread. Such accelerators will employ advanced beam conditioning systems such as emittance exchangers to manipulate high brightness beams. One of the goals of the Fermilab A0 photoinjector is to investigate the transverse to longitudinal emittance exchange principle. Coherent synchrotron radiation could limit high current operation of the emittance exchanger. In this paper, we report on the preliminary experimental and simulation study of the coherent synchroton radiation (CSR) in the emittance exchange line at the A0 photoinjector.

  2. Design study of a low-emittance high-repetition rate thermionic rf gun

    Directory of Open Access Journals (Sweden)

    A. Opanasenko

    2017-05-01

    Full Text Available We propose a novel gridless continuous-wave radiofrequency (rf thermionic gun capable of generating nC ns electron bunches with a rms normalized slice emittance close to the thermal level of 0.3 mm mrad. In order to gate the electron emission, an externally heated thermionic cathode is installed into a stripline-loop conductor. Two high-voltage pulses propagating towards each other in the stripline-loop overlap in the cathode region and create a quasielectrostatic field gating the electron emission. The repetition rate of pulses is variable and can reach up to one MHz with modern solid-state pulsers. The stripline attached to a rf gun cavity wall has with the wall a common aperture that allows the electrons to be injected into the rf cavity for further acceleration. Thanks to this innovative gridless design, simulations suggest that the bunch emittance is approximately at the thermal level after the bunch injection into the cavity provided that the geometry of the cathode and aperture are properly designed. Specifically, a concave cathode is adopted to imprint an Ƨ-shaped distribution onto the beam transverse phase-space to compensate for an S-shaped beam distribution created by the spherical aberration of the aperture-cavity region. In order to compensate for the energy spread caused by rf fields of the rf gun cavity, a 3rd harmonic cavity is used. A detailed study of the electrodynamics of the stripline and rf gun cavity as well as the beam optics and bunch dynamics are presented.

  3. Experimental studies on coherent synchrotron radiation at an emittance exchange beam line

    Directory of Open Access Journals (Sweden)

    J. C. T. Thangaraj

    2012-11-01

    Full Text Available One of the goals of the Fermilab A0 photoinjector is to investigate experimentally the transverse to longitudinal emittance exchange (EEX principle. Coherent synchrotron radiation in the emittance exchange line could limit the performance of the emittance exchanger at short bunch lengths. In this paper, we present experimental and simulation studies of the coherent synchrotron radiation (CSR in the emittance exchange line at the A0 photoinjector. We report on time-resolved CSR studies using a skew-quadrupole technique. We also demonstrate the advantages of running the EEX with an energy-chirped beam.

  4. Experimental studies on coherent synchrotron radiation at an emittance exchange beam line

    Science.gov (United States)

    Thangaraj, J. C. T.; Thurman-Keup, R.; Ruan, J.; Johnson, A. S.; Lumpkin, A. H.; Santucci, J.

    2012-11-01

    One of the goals of the Fermilab A0 photoinjector is to investigate experimentally the transverse to longitudinal emittance exchange (EEX) principle. Coherent synchrotron radiation in the emittance exchange line could limit the performance of the emittance exchanger at short bunch lengths. In this paper, we present experimental and simulation studies of the coherent synchrotron radiation (CSR) in the emittance exchange line at the A0 photoinjector. We report on time-resolved CSR studies using a skew-quadrupole technique. We also demonstrate the advantages of running the EEX with an energy-chirped beam.

  5. A numerical study of emittance growths in RF guns

    CERN Document Server

    Masuda, K; Sobajima, M; Kitagaki, J; Ohnishi, M; Toku, H; Yoshikawa, K

    1999-01-01

    A beam with greatly reduced emittance is required for further improvements of FELs, in particular, for FELs of shorter wavelengths, and of narrower bandwidths. From this viewpoint, the BNL/SLAC/UCLA 1.6-cell S-band photocathode RF gun performance characteristics were calculated, first in order to evaluate what may contribute to the emittance growths in photocathode RF guns. We developed an RF gun to produce an electron beam with an extremely low emittance, by using a 2-D simulation code. It is found that, by optimizing the laser injection phase, the drive laser spot radius and the cavity shape around the laser spot, the beam emittance by the 1.6-cell RF gun can be greatly reduced to 2.1 pi mm mrad, from the previous 4.4 pi mm mrad of the original shape.

  6. Numerical studies of emittance exchange in 2-D charged-particle beams

    International Nuclear Information System (INIS)

    Guy, F.W.

    1986-01-01

    We describe results obtained from a two-dimensional particle-following computer code that simulates a continuous, nonrelativistic, elliptical charged-particle beam with linear continuous focusing. Emittances and focusing strengths can be different in the two transverse directions. The results can be applied, for example, for a quadrupole transport system in a smooth approximation to a real beam with unequal emittances in the two planes. The code was used to study emittance changes caused by kinetic-energy exchange between transverse directions and by shifts in charge distributions. Simulation results for space-charge-dominated beams agree well with analytic formulas. From simulation results, an empirical formula was developed for a ''partition parameter'' (the ratio of kinetic energies in the two directions) as a function of initial conditions and beamline length. Quantitative emittance changes for each transverse direction can be predicted by using this parameter. Simulation results also agree with Hofmann's generalized differential equation relating emittance and field energy

  7. Emitter depletion studies on electrodes of 50 Hz mercury/noble gas discharge lamps during ignition

    International Nuclear Information System (INIS)

    Hoek, W.J. van den; Thijssen, T.L.G.; Heijden, A.J.H. van der; Buijsse, B.; Haverlag, M.

    2002-01-01

    The depletion of emitter from the oxide cathodes during the glow switch starting of the discharge in 50 Hz operated low-pressure mercury/noble gas discharge lamps (fluorescent lamps) has been studied. It follows from pulse ignition studies and computer-controlled ignition experiments that two plasma modes exist during ignition: a glow discharge and a vapour-arc discharge. The occurrence of these modes depends on the point of interruption with respect to the phase of the 50 Hz preheat current. The vapour arc appears to be the dominant mechanism of emitter depletion. The average emitter loss per vapour-arc pulse has been quantified by radioactive Ba tracer experiments. The nature of the vapour arc has been studied by fast photography and SEM. The vapour arc involves dielectric breakdown over the non-conducting oxide mass and gives rise to explosive emitter vapourization. (author)

  8. Studies on space charge neutralization and emittance measurement of beam from microwave ion source

    Energy Technology Data Exchange (ETDEWEB)

    Misra, Anuraag; Goswami, A.; Sing Babu, P.; Srivastava, S.; Pandit, V. S., E-mail: pandit@vecc.gov.in, E-mail: vspandit12@gmail.com [Variable Energy Cyclotron Centre, 1-AF, Bidhannagar, Kolkata 700 064 (India)

    2015-11-15

    A 2.45 GHz microwave ion source together with a beam transport system has been developed at VECC to study the problems related with the injection of high current beam into a compact cyclotron. This paper presents the results of beam profile measurement of high current proton beam at different degrees of space charge neutralisation with the introduction of neon gas in the beam line using a fine leak valve. The beam profiles have been measured at different pressures in the beam line by capturing the residual gas fluorescence using a CCD camera. It has been found that with space charge compensation at the present current level (∼5 mA at 75 keV), it is possible to reduce the beam spot size by ∼34%. We have measured the variation of beam profile as a function of the current in the solenoid magnet under the neutralised condition and used these data to estimate the rms emittance of the beam. Simulations performed using equivalent Kapchinsky-Vladimirsky beam envelope equations with space charge neutralization factor are also presented to interpret the experimental results.

  9. Emittance studies of the 2.45 GHz permanent magnet ECR ion source

    Science.gov (United States)

    Zelenak, A.; Bogomolov, S. L.; Yazvitsky, N. Yu.

    2004-05-01

    During the past several years different types of permanent magnet 2.45 GHz (electron cyclotron resonance) ion sources were developed for production of singly charged ions. Ion sources of this type are used in the first stage of DRIBs project, and are planned to be used in the MASHA mass separator. The emittance of the beam provided by the source is one of the important parameters for these applications. An emittance scanner composed from a set of parallel slits and rotary wire beam profile monitor was used for the studying of the beam emittance characteristics. The emittance of helium and argon ion beams was measured with different shapes of the plasma electrode for several ion source parameters: microwave power, source potential, plasma aperture-puller aperture gap distance, gas pressure. The results of measurements are compared with previous simulations of ion optics.

  10. Emittance studies of the 2.45 GHz permanent magnet ECR ion source

    International Nuclear Information System (INIS)

    Zelenak, A.; Bogomolov, S.L.; Yazvitsky, N.Yu.

    2004-01-01

    During the past several years different types of permanent magnet 2.45 GHz (electron cyclotron resonance) ion sources were developed for production of singly charged ions. Ion sources of this type are used in the first stage of DRIBs project, and are planned to be used in the MASHA mass separator. The emittance of the beam provided by the source is one of the important parameters for these applications. An emittance scanner composed from a set of parallel slits and rotary wire beam profile monitor was used for the studying of the beam emittance characteristics. The emittance of helium and argon ion beams was measured with different shapes of the plasma electrode for several ion source parameters: microwave power, source potential, plasma aperture-puller aperture gap distance, gas pressure. The results of measurements are compared with previous simulations of ion optics

  11. Studies and calculations of transverse emittance growth in proton storage rings

    International Nuclear Information System (INIS)

    Mane, S.R.; Jackson, G.

    1989-01-01

    When high energy storage rings are used to collide beams of particles and antiparticles for high energy physics experiments, it is important to obtain as high an integrated luminosity as possible. Reduction of integrated luminosity can arise from several factors, in particular from growth of the transverse beam sizes (transverse emittances). We have studied the problem of transverse emittance growth in high energy storage rings caused by random dipole noise kicks to the beam. A theoretical formula for the emittance growth rate is derived, and agreement is obtained with experimental measurements where noise of known amplitude and power spectrum was deliberately injected into the Fermilab Tevatron, to kick the beam randomly. In the experiment, phase noise was introduced into the Tevatron rf system, and the measured dependence of horizontal emittance growth on phase noise amplitude is compared against the theoretically derived response. (orig.)

  12. Progress with Long-Range Beam-Beam Compensation Studies for High Luminosity LHC

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Adriana; et al.

    2017-05-01

    Long-range beam-beam (LRBB) interactions can be a source of emittance growth and beam losses in the LHC during physics and will become even more relevant with the smaller '* and higher bunch intensities foreseen for the High Luminosity LHC upgrade (HL-LHC), in particular if operated without crab cavities. Both beam losses and emittance growth could be mitigated by compensat-ing the non-linear LRBB kick with a correctly placed current carrying wire. Such a compensation scheme is currently being studied in the LHC through a demonstration test using current-bearing wires embedded into col-limator jaws, installed either side of the high luminosity interaction regions. For HL-LHC two options are considered, a current-bearing wire as for the demonstrator, or electron lenses, as the ideal distance between the particle beam and compensating current may be too small to allow the use of solid materials. This paper reports on the ongoing activities for both options, covering the progress of the wire-in-jaw collimators, the foreseen LRBB experiments at the LHC, and first considerations for the design of the electron lenses to ultimately replace material wires for HL-LHC.

  13. A critical study of emittance measurements of intense low-energy proton beams

    CERN Document Server

    Evans, Lyndon R

    1972-01-01

    The measurement of emittance in low energy proton beams suffers from two perturbing effects: 1) the neutralisation of the beam by backstreaming secondary electrons and 2) the space charge blowup of the beam sample between defining and analysing apparatus. An experimental study shows a significant change of the emittance orientation when bias is used to eliminate the secondary electrons. Biased and non-biased cases are also compared with computed dynamics including space charge. Criteria for the slit size and drift distance which make the space charge blow-up negligible are derived. In addition a transverse coherent oscillation of the proton beam, which was revealed the measurements, is discussed briefly. (11 refs).

  14. Emittance preservation

    Energy Technology Data Exchange (ETDEWEB)

    Kain, V; Arduini, G; Goddard, B; Holzer, B J; Jowett, J M; Meddahi, M; Mertens, T; Roncarolo, F; Schaumann, M; Versteegen, R; Wenninger, J [European Organization for Nuclear Research, Geneva (Switzerland)

    2012-07-01

    Emittance measurements during the LHC proton run 2011 indicated a blow-up of 20 % to 30 % from LHC injection to collisions. This presentation will show the emittance preservation throughout the different parts of the LHC cycle and discuss the current limitations on emittance determination. An overview of emittance preservation through the injector complex as function of bunch intensity will also be given. Possible sources for the observed blow-up and required tests in 2012 will be presented. Possible improvements of emittance diagnostics and analysis tools for 2012 will be shown.

  15. Theoretical Study of Watershed Eco-Compensation Standards

    Science.gov (United States)

    Yan, Dandan; Fu, Yicheng; Liu, Biu; Sha, Jinxia

    2018-01-01

    Watershed eco-compensation is an effective way to solve conflicts over water allocation and ecological destruction problems in the exploitation of water resources. Despite an increasing interest in the topic, the researches has neglected the effect of water quality and lacked systematic calculation method. In this study we reviewed and analyzed the current literature and proposedatheoretical framework to improve the calculation of co-compensation standard.Considering the perspectives of the river ecosystems, forest ecosystems and wetland ecosystems, the benefit compensation standard was determined by the input-output corresponding relationship. Based on the opportunity costs related to limiting development and water conservation loss, the eco-compensation standard was calculated.In order to eliminate the defects of eco-compensation implementation, the improvement suggestions were proposed for the compensation standard calculation and implementation.

  16. Study of thick, nuclear-compensated silicon detectors; Etude des detecteurs epais au silicium compense nucleairement

    Energy Technology Data Exchange (ETDEWEB)

    Le Coroller, Y. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-09-01

    A study is made here, from the point of view of the realization and the performance, of thick nuclear-compensated silicon detectors. After recalling the need for compensation and reviewing the existing methods, the author describes in detail the controlled realization of thick detectors by nuclear compensation from the theoretical and experimental points of view. The practical precautions which should be observed are given: control of the homogeneity of the starting material, control of the evolution of the compensation, elimination of parasitic processes. The performances of the detectors obtained are then studied: electrical characteristics (current, life-time) on the one hand, detection and spectrometry of penetrating radiations on the other hand. The results show, that the compensated diodes having an effective thickness of two millimeters operate satisfactorily as detectors for applied voltages of about 500 volts. The resolutions observed are then about 2 per cent for mono-energetic electrons and about 4 per cent for the gamma; they can be improved by the use of a pre-amplifier of very low background noise. (author) [French] Les detecteurs epais au silicium compense nucleairement sont etudies ici du double point de vue realisation et performances. Apres un rappel sur la necessite de la compensation et les procedes existants, la realisation controlee des detecteurs epais par compensation nucleaire est decrite en detail sous l'aspect theorique et l'aspect experimental. On met en evidence les precautions a prendre dans la pratique: controle de l'homogeneite du materiau de base, controle de l'evolution de la compensation, elimination des processus parasites. On etudie ensuite les performances de detecteurs obtenus : caracteristiques electriques (courant, duree de vie) d'une part, d'autre part detection et spectrometrie des rayonnements penetrants. Les resultats montrent que les diodes compensees ayant une epaisseur utile de deux

  17. Study of thick, nuclear-compensated silicon detectors; Etude des detecteurs epais au silicium compense nucleairement

    Energy Technology Data Exchange (ETDEWEB)

    Le Coroller, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-09-01

    A study is made here, from the point of view of the realization and the performance, of thick nuclear-compensated silicon detectors. After recalling the need for compensation and reviewing the existing methods, the author describes in detail the controlled realization of thick detectors by nuclear compensation from the theoretical and experimental points of view. The practical precautions which should be observed are given: control of the homogeneity of the starting material, control of the evolution of the compensation, elimination of parasitic processes. The performances of the detectors obtained are then studied: electrical characteristics (current, life-time) on the one hand, detection and spectrometry of penetrating radiations on the other hand. The results show, that the compensated diodes having an effective thickness of two millimeters operate satisfactorily as detectors for applied voltages of about 500 volts. The resolutions observed are then about 2 per cent for mono-energetic electrons and about 4 per cent for the gamma; they can be improved by the use of a pre-amplifier of very low background noise. (author) [French] Les detecteurs epais au silicium compense nucleairement sont etudies ici du double point de vue realisation et performances. Apres un rappel sur la necessite de la compensation et les procedes existants, la realisation controlee des detecteurs epais par compensation nucleaire est decrite en detail sous l'aspect theorique et l'aspect experimental. On met en evidence les precautions a prendre dans la pratique: controle de l'homogeneite du materiau de base, controle de l'evolution de la compensation, elimination des processus parasites. On etudie ensuite les performances de detecteurs obtenus : caracteristiques electriques (courant, duree de vie) d'une part, d'autre part detection et spectrometrie des rayonnements penetrants. Les resultats montrent que les diodes compensees ayant une epaisseur utile de deux millimetres fonctionnent

  18. Fatigue studies in compensated bulk lead zirconate titanate

    International Nuclear Information System (INIS)

    Verdier, Cyril; Morrison, Finlay D.; Lupascu, Doru C.; Scott, James F.

    2005-01-01

    Impedance analysis studies were carried out on compensated bulk lead zirconate titanate samples. Fatigue is concomitant with the onset of dielectric loss. This is shown to be dominantly due to an irreversibly modified near-surface layer that can be polished off. The highly compensated nature of these samples minimizes the role of oxygen vacancies

  19. Low emittance photoinjectors

    International Nuclear Information System (INIS)

    Ferrario, Massimo

    2001-01-01

    Photon colliders require high charge polarized electron beams with very low normalized emittances, possibly lower than the actual damping rings design goals. Recent analytical and numerical efforts in understanding beam dynamics in RF photoinjectors have raised again the question as to whether the performances of an RF electron gun based injector could be competitive with respect to a damping ring. As a matter of discussion we report in this paper the most recent results concerning low emittance photoinjector designs: the production of polarized electron beams by DC and/or RF guns is illustrated together with space charge compensation techniques and thermal emittance effects. New ideas concerning multi-gun injection system and generation of flat beams by RF gun are also discussed

  20. Studies on the photodegradation of red, green and blue phosphorescent OLED emitters

    Directory of Open Access Journals (Sweden)

    Susanna Schmidbauer

    2013-10-01

    Full Text Available The photodegradation behavior of four well-established iridium emitters was investigated. Irradiation of the samples in different solvents and under atmospheric as well as inert conditions helped to identify several pathways that can contribute to the deterioration of these compounds. Degradation via singlet oxygen or the excited states of the emitters as well as the detrimental influence of halogenated solvents are discussed for the different investigated iridium complexes. Some of the resulting degradation products could be identified by using LC–MS or other analytical techniques. The results show how even small structural changes can have a huge influence on rate and mechanism of the photodegradation. The observations from this study may help to better understand degradation processes occurring during the handling of the materials, but also during device processing and operation.

  1. Design Study of Low-Emittance Injector for SASE-XFEL at Pohang Accelerator Laboratory

    CERN Document Server

    Park, Sungju J; Yun, H J; Kim, D E; Kim, E S; Ko, In Soo; Nam, S H; Oh, Jong Seok

    2004-01-01

    We report on the design study of the low-emittance injector for the SASE-XFEL that is being considered as a possible choice for the next-generation light sources at the Pohang Accelerator Laboratory, POSTECH. Using the PARMELA code, beam dynamics simulations were performed aiming to achieve the invariant-envelope matching at booster entrance, and to insure beam emittance < 1 mm.mrad (at 1-nC bunch charge) at the injector end. We also utilized the MAGIC code for analyzing beam dynamics inside the RF-gun cavities and to confirm the part of PARMELA simulations. Hardware design was done with possible implementation of high-Q.E. photocathode, which could reduce burdens imposed on laser system, thus improving overall system stability and reliability.

  2. Studies and calculations of transverse emittance growth in high-energy proton storage rings

    International Nuclear Information System (INIS)

    Mane, S.R.; Jackson, G.

    1989-03-01

    In the operation of proton-antiproton colliders, an important goal is to maximize the integrated luminosity. During such operations in the Fermilab Tevatron, the transverse beam emittances were observed to grow unexpectedly quickly, thus causing a serious reduction of the luminosity. We have studied this phenomenon experimentally and theoretically. A formula for the emittance growth rate, due to random dipole kicks, is derived. In the experiment, RF phase noise of known amplitude was deliberately injected into the Tevatron to kick the beam randomly, via dispersion at the RF cavities. Theory and experiment are found to agree reasonably well. We also briefly discuss the problem of quadrupole kicks. 14 refs., 2 figs., 3 tabs

  3. Experimental studies on coherent synchrotron radiaiton in the emittance exchange line at the Fermilab A0 Photoinjector

    International Nuclear Information System (INIS)

    Thangaraj, J.C.T.; Keup, R.; Johnson, A.; Ruan, J.; Piot, P.; Church, M.; Edwards, H.; Lumpkin, A.; Sun, Y.-E.; Santucci, J.

    2011-01-01

    Future accelerators will employ advanced beam conditioning systems such as emittance exchangers to manipulate high brightness beams. Coherent synchrotron radiation (CSR) in the dipoles could limit the performance of the emittance exchanger. In this paper, we report the experimental studies on measuring CSR and its effects on the beam at the A0 photoinjector in the emittance exchange line. After reporting the CSR power measurements, we report on the diagnostic scheme based on a weak skew quad in the emittance exchange line to study the CSR effects on the beam and other beam dynamics. In this work, we have reported on CSR measurements and the effect of skew quad on the dogleg line with the 5-cell turned on and off. We plan to study CSR effects on the bunch with the 5-cell on at larger chirp. This is will not only increase the CSR self-effect but also reduce the beamsize at the screen for convenient beamsize measurements.

  4. Transport and emittance study for 18 GHz superconducting-ECR ion source at RCNP.

    Science.gov (United States)

    Yorita, T; Hatanaka, K; Fukuda, M; Ueda, H; Kibayashi, M; Morinobu, S; Tamii, A

    2012-02-01

    As the upgrade program of the azimuthally varying field (AVF) cyclotron is at the cyclotron facility of the RCNP, Osaka University for the improvement of the quality, stability, and intensity of accelerated beams, an 18 GHz superconducting (SC) ECR ion source has been installed to increase beam currents and to extend the variety of ions, especially for highly charged heavy ions which can be accelerated by RCNP AVF cyclotron. The production development of several ions such as B, O, N, Ne, Ar, Ni, Kr, and Xe has been performed by Yorita et al. [Rev. Sci. Instrum. 79, 02A311(2008); 81, 02A332 (2010)]. Further studies for the beam transport have been done in order to improve the beam current more for injection of cyclotron. The effect of field leakage of AVF main coil is not negligible and additional steering magnet has been installed and then beam transmission has been improved. The emittance monitor has also been developed for the purpose of investigating correlation between emittance of beam from ECR ion sources and injection efficiency. The monitor consists with BPM82 with rotating wire for fast measurement for efficient study.

  5. Selección tecnico-economica de emisores Technical and economical selection of emitters

    Directory of Open Access Journals (Sweden)

    Eduardo A. Holzapfel

    2007-12-01

    Full Text Available El presente trabajo tuvo como objetivo estudiar los factores que intervienen en la selección técnico económico de goteros. En el estudio fueron utilizados emisores autocompensados y no autocompensados, considerando a los aspectos técnicos como porcentaje de suelo humedecido, número de emisores por planta y coeficiente de uniformidad y precio y la presión de operación del emisor como aspectos económicos. Los resultados muestran que la presión de operación de los emisores es el factor más importante a considerar en la selección, ya que para valores más bajos de presión de operación se obtuvieron menores valores de costo total anualizado, independiente del tipo de gotero. En general, los goteros no autocompesados presentaron valores de costo anualizado menores, para un rango de presión similar. Finalmente el análisis tecnico-económico en la selección de emisores es un procedimiento importante.The objective of this research was to study the parameters that affect the technical-economical selection of emitters. In the study compensated and non-compensated emitters were used. The technical aspects considered were: percentage of wetted soil, number of emitters per plant and the uniformity coefficient as well as price and operation pressure for economic aspects. The results shows that the operation pressure of emitters is the most important factor to be considered in the selection , with smaller values of pressure giving lower total annual cost, independently of the type of emitter. In general, the non-compensated emitter shows lower annual cost values than for compensated emitters, for a similar range of pressures. Finally the technical-economical analysis in the emitter selection is an important procedure.

  6. Impact of Optics on CSR-Related Emittance Growth in Bunch Compressor Chicanes

    CERN Document Server

    Limberg, Torsten

    2005-01-01

    The dependence of emittance growth due to Coherent Synchrotron Radiation (CSR) in bunch compressor chicanes on optics has been noticed and empirically studied in the past. We revisit the subject, suggesting a model to explain slice emittance growth dependence on chicane optics. A simplified model to calculate projected emittance growth when it is mainly caused by transverse slice centroid offsets is presented. It is then used to find optimal compensation of centroid kicks in the single chicanes of a two-stage compression system by adjusting the phase advance of the transport in between and the ration of the compression factors.

  7. Studies of gamma emitters in the alluvial deposit and in water of the Bug River

    International Nuclear Information System (INIS)

    Chibowski, S.; Pawlik, M.

    1995-01-01

    Studies of the contents of gamma emitters in samples of water and deposit taken from the Bug River (in Poland only) are presented. The total γ-activity of deposits ranges from 120-650 Bq/kg and the average value is 350 Bq/kg. The elevated activity is chiefly due to the presence of natural radionuclides. The main artificial radionuclides are Cs-137 and Cs-134, whose contribution to the total activity ranges from 0.2 to 6%. The activity of waters samples is low, namely, 1.7-3.5 Bq/kg and is due to the presence of natural radionuclides. The heterogeneity of the distribution of natural and artificial radionuclides in the studies samples reveals the effect of economical and industrial activities on contamination of the Bug. (author). 7 refs, 1 fig., 4 tabs

  8. Emittance investigation of RF photo-injector

    CERN Document Server

    Yang Mao Rong; Li Zheng; Li Ming; Xu Zhou

    2002-01-01

    A high-power laser beam illuminates a photocathode surface placed on an end wall of an RF cavity. The emitted electrons are accelerated immediately to a relativistic energy by the strong RF find in the cavity. But space charge effect induces beam emittance growth especially near the cathode where the electrons are still nonrelativistic. The author analyzes the factors which lead the transverse emittance growth and method how to resolve this problem. After introducing solenoidal focusing near the photocathode, the beam emittance growth is suppressed dramatically. The beam emittance is given also after compensation and simulation results. The measurements show these results are coincident

  9. Cash or Credit? Compensation in Psychology Studies: Motivation Matters

    Directory of Open Access Journals (Sweden)

    Holly J. Bowen

    2017-05-01

    Full Text Available It is common practice for psychology researchers to recruit their sample of participants from the undergraduate student population. Participants are typically compensated with partial course credit or a monetary payment. The current study reveals that the motivation to participate in a study (cash versus course credit can relate to performance on a behavioral task of rewarded memory. In Experiment 1, undergraduate participants were recruited and compensated for their time with either partial course credit or cash. Potential performance-based cash rewards were earned during a rewarded memory task, where correct recognition of half the stimuli was worth a high reward and the other half a low reward. Memory for high reward items was better than low reward items, but only for the cash group. The credit group did not modulate their performance based on the value of the stimuli. In Experiment 2, undergraduates were compensated with partial course credit for their time and given the opportunity to earn a bonus credit for performance on a memory test. The findings were in line with the results from the credit group of Experiment 1, suggesting that the modulation of performance in the cash group of Experiment 1 cannot be accounted for by congruency between motivation to participate and reward for task performance. Of methodological importance, the findings indicate that recruiting and compensating participants with cash versus course credit may influence the results on a rewarded memory task. This factor should be taken into consideration in studies of reward motivation.

  10. Beam structure and transverse emittance studies of high-energy ion beams

    International Nuclear Information System (INIS)

    Saadatmand, K.; Johnson, K.F.; Schneider, J.D.

    1991-01-01

    A visual diagnostic technique has been developed to monitor and study ion beam structure shape and size along a transport line. In this technique, a commercially available fluorescent screen is utilized in conjunction with a video camera. This visual representation of the beam structure is digitized and enhanced through use of false-color coding and displayed on a TV monitor for on-line viewing. Digitized information is stored for further off-line processing (e.g., extraction of beam profiles). An optional wire grid placed upstream of the fluor screen adds the capability of transverse emittance (or angular spread) measurement to this technique. This diagnostic allows real-time observation of the beam response to parameter changes (e.g., evolution of the beam structure, shifts in the beam intensity at various spatial locations within the beam perimeter, and shifts in the beam center and position). 3 refs., 5 figs

  11. Analytical and numerical study of New field emitter processing for superconducting cavities

    Science.gov (United States)

    Volkov, Vladimir; Petrov, Victor

    2018-02-01

    In this article a scientific prove for a new technology to maximize the accelerating gradient in superconducting cavities by processing on higher order mode frequencies is presented. As dominant energy source the heating of field emitters by an induced rf current (rf-heating) is considered. The field emitter structure is assumed to be a chain of conductive particles, which are formed by attractive forces.

  12. Cancer from internal emitters

    International Nuclear Information System (INIS)

    Boecker, B.B.; Griffith, W.C. Jr.

    1995-01-01

    Irradiation from internal emitters, or internally deposited radionuclides, is an important component of radiation exposures encountered in the workplace, home, or general environment. Long-term studies of human populations exposed to various internal emitters by different routes of exposure are producing critical information for the protection of workers and members of the general public. The purpose of this report is to examine recent developments and discuss their potential importance for understanding lifetime cancer risks from internal emitters. The major populations of persons being studied for lifetime health effects from internally deposited radionuclides are well known: Lung cancer in underground miners who inhaled Rn progeny, liver cancer from persons injected with the Th-containing radiographic contrast medium Thorotrast, bone cancer from occupational or medical intakes of 226 Ra or medical injections of 224 Ra, and thyroid cancer from exposures to iodine radionuclides in the environment or for medical purposes

  13. Transverse emittance dilution due to coupler kicks in linear accelerators

    Directory of Open Access Journals (Sweden)

    Brandon Buckley

    2007-11-01

    Full Text Available One of the main concerns in the design of low emittance linear accelerators (linacs is the preservation of beam emittance. Here we discuss one possible source of emittance dilution, the coupler kick, due to transverse electromagnetic fields in the accelerating cavities of the linac caused by the power coupler geometry. In addition to emittance growth, the coupler kick also produces orbit distortions. It is common wisdom that emittance growth from coupler kicks can be strongly reduced by using two couplers per cavity mounted opposite each other or by having the couplers of successive cavities alternate from above to below the beam pipe so as to cancel each individual kick. While this is correct, including two couplers per cavity or alternating the coupler location requires large technical changes and increased cost for superconducting cryomodules where cryogenic pipes are arranged parallel to a string of several cavities. We therefore analyze consequences of alternate coupler placements. We show here that alternating the coupler location from above to below compensates the emittance growth as well as the orbit distortions. For sufficiently large Q values, alternating the coupler location from before to after the cavity leads to a cancellation of the orbit distortion but not of the emittance growth, whereas alternating the coupler location from before and above to behind and below the cavity cancels the emittance growth but not the orbit distortion. We show that cancellations hold for sufficiently large Q values. These compensations hold even when each cavity is individually detuned, e.g., by microphonics. Another effective method for reducing coupler kicks that is studied is the optimization of the phase of the coupler kick so as to minimize the effects on emittance from each coupler. This technique is independent of the coupler geometry but relies on operating on crest. A final technique studied is symmetrization of the cavity geometry in the

  14. Beam phase space and emittance

    International Nuclear Information System (INIS)

    Buon, J.

    1990-12-01

    The classical and elementary results for canonical phase space, the Liouville theorem and the beam emittance are reviewed. Then, the importance of phase portraits to obtain a geometrical description of motion is emphasized, with examples in accelerator physics. Finally, a statistical point of view is used to define beam emittance, to study its law of approximate conservation and to treat two particular examples

  15. Experimental studies of emittance growth and energy spread in a photocathode RF gun

    International Nuclear Information System (INIS)

    Yang, J.; Sakai, F.; Okada, Y.; Yorozu, M.; Yanagida, T.; Endo, A.

    2002-01-01

    In this paper we report on a low emittance electron source, based on a photocathode RF gun, a solenoid magnet and a subsequent linac. The dependencies of the beam transverse emittance and relative energy spread with respect to the laser injection phase of the radio-frequency (RF) gun, the RF phase of the linac and the bunch charge were investigated experimentally. It was found that a lower beam emittance is observed when the laser injection phase in the RF gun is low. The emittance increases almost linearly with the bunch charge under a constant solenoid magnetic field. The corrected relative energy spread of the beam is not strongly dependent on the bunch charge. Finally, an optimal normalized rms transverse emittance of 1.91±0.28 πmm mrad at a bunch charge of 0.6 nC was obtained when the RF gun was driven by a picosecond Nd:YAG laser. A corrected relative rms energy spread of 0.2-0.25% at a bunch charge of 0.3-2 nC was obtained after the beam was accelerated to 14 MeV by the subsequent linac

  16. Experimental studies of emittance growth and energy spread in a photocathode RF gun

    CERN Document Server

    Yang, J; Okada, Y; Yorozu, M; Yanagida, T; Endo, A

    2002-01-01

    In this paper we report on a low emittance electron source, based on a photocathode RF gun, a solenoid magnet and a subsequent linac. The dependencies of the beam transverse emittance and relative energy spread with respect to the laser injection phase of the radio-frequency (RF) gun, the RF phase of the linac and the bunch charge were investigated experimentally. It was found that a lower beam emittance is observed when the laser injection phase in the RF gun is low. The emittance increases almost linearly with the bunch charge under a constant solenoid magnetic field. The corrected relative energy spread of the beam is not strongly dependent on the bunch charge. Finally, an optimal normalized rms transverse emittance of 1.91+-0.28 pi mm mrad at a bunch charge of 0.6 nC was obtained when the RF gun was driven by a picosecond Nd:YAG laser. A corrected relative rms energy spread of 0.2-0.25% at a bunch charge of 0.3-2 nC was obtained after the beam was accelerated to 14 MeV by the subsequent linac.

  17. Investigation of slice emittance using an energy-chirped electron beam in a dispersive section for photo injector characterization at PITZ

    Energy Technology Data Exchange (ETDEWEB)

    Ivanisenko, Yevgeniy

    2012-06-15

    This work describes a transverse slice emittance diagnostics with an RMS temporal resolution down to 2 ps that was implemented at the Photo Injector Test facility in Zeuthen (PITZ). The measurements were performed for several bunch charges generated by a laser pulse that has a flat-top temporal profile of 21-22 ps FWHM duration. This diagnostics allows to study the beam projected emittance compensation with a solenoid magnetic field experimentally and therefore contributes to the beam emittance optimization for the needs of short wavelength linac-based FELs in particular. The diagnostics is based upon the usage of electron bunches which have a correlation between the longitudinal position and the momentum of the bunch particles. This property allows to convert the bunch longitudinal distribution into a transverse one in a dipole magnet. A slit with a narrow opening at the dipole exit selects a fraction of the particle ensemble, a slice, which emittance is analyzed at a screen downstream. Slit scan and quadrupole scan techniques can be used to measure the emittance of the slices. In the experiments it was found that the slice emittance values are 5-10% lower than the projected emittance values, indicating a good effectivity of the solenoid compensation. The emittance obtained using quadrupole scan technique has shown different results when compared to slit scan technique due to a beam halo. The observed beam halo in phase space contributes up to 40% of the emittance value while having only 10% of the bunch charge.

  18. Investigation of slice emittance using an energy-chirped electron beam in a dispersive section for photo injector characterization at PITZ

    International Nuclear Information System (INIS)

    Ivanisenko, Yevgeniy

    2012-06-01

    This work describes a transverse slice emittance diagnostics with an RMS temporal resolution down to 2 ps that was implemented at the Photo Injector Test facility in Zeuthen (PITZ). The measurements were performed for several bunch charges generated by a laser pulse that has a flat-top temporal profile of 21-22 ps FWHM duration. This diagnostics allows to study the beam projected emittance compensation with a solenoid magnetic field experimentally and therefore contributes to the beam emittance optimization for the needs of short wavelength linac-based FELs in particular. The diagnostics is based upon the usage of electron bunches which have a correlation between the longitudinal position and the momentum of the bunch particles. This property allows to convert the bunch longitudinal distribution into a transverse one in a dipole magnet. A slit with a narrow opening at the dipole exit selects a fraction of the particle ensemble, a slice, which emittance is analyzed at a screen downstream. Slit scan and quadrupole scan techniques can be used to measure the emittance of the slices. In the experiments it was found that the slice emittance values are 5-10% lower than the projected emittance values, indicating a good effectivity of the solenoid compensation. The emittance obtained using quadrupole scan technique has shown different results when compared to slit scan technique due to a beam halo. The observed beam halo in phase space contributes up to 40% of the emittance value while having only 10% of the bunch charge.

  19. Beam dynamics studies and emittance optimization in the CTF3 linac at CERN

    CERN Document Server

    Urschütz, Peter; Corsini, Roberto; Döbert, Steffen; Ferrari, Arnaud; Tecker, Frank

    2006-01-01

    Small transverse beam emittances and well-known lattice functions are crucial for the 30 GHz power production in the Power Extraction and Transfer Structure (PETS) and for the commissioning of the Delay Loop of the CLIC Test Facility 3 (CTF3). Following beam dynamics simulation results, two additional solenoids were installed in the CTF3 injector in order to improve the emittance. During the runs in 2005 and 2006, an intensive measurement campaign to determine Twiss parameters and beam sizes was launched. The results obtained by means of quadrupole scans for different modes of operation suggest emittances well below the nominal .n,rms = 100 ?Î?Êm and a good agreement with PARMELA simulations.

  20. Low-emittance uniform density Cs+ sources for heavy ion fusion accelerators studies

    International Nuclear Information System (INIS)

    Eylon, S.; Henestroza, E.; Garvey, T.; Johnson, R.; Chupp, W.

    1991-04-01

    Low-emittance (high-brightness) Cs + thermionic sources were developed for the heavy ion induction linac experiment MBE-4 at LBL. The MBE-4 linac accelerates four 10 mA beams from 200 ke V to 900 ke V while amplifying the current up to a factor of nine. Recent studies of the transverse beam dynamics suggested that characteristics of the injector geometry were contributing to the normalized transverse emissions growth. Phase-space and current density distribution measurements of the beam extracted from the injector revealed overfocusing of the outermost rays causing a hollow density profile. We shall report on the performance of a 5 mA scraped beam source (which eliminates the outermost beam rays in the diode) and on the design of an improved 10 mA source. The new source is based on EGUN calculations which indicated that a beam with good emissions and uniform current density could be obtained by modifying the cathode Pierce electrodes and using a spherical emitting surface. The measurements of the beam current density profile on a test stand were found to be in agreement with the numerical simulations. 3 refs., 6 figs

  1. FACET Emittance Growth

    Energy Technology Data Exchange (ETDEWEB)

    Frederico, J; Hogan, M.J.; Nosochkov, Y.; Litos, M.D.; Raubenheimer, T.; /SLAC

    2011-04-05

    FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration. The FACET beamline consists of a chicane and final focus system to compress the 23 GeV, 3.2 nC electron bunches to {approx}20 {micro}m long and {approx}10 {micro}m wide. Simulations of the FACET beamline indicate the short-duration and large, 1.5% rms energy spread beams may suffer a factor of four emittance growth from a combination of chromaticity, incoherent synchrotron radiation (ISR), and coherent synchrotron radiation (CSR). Emittance growth is directly correlated to head erosion in plasma wakefield acceleration and is a limiting factor in single stage performance. Studies of the geometric, CSR, and ISR components are presented. Numerical calculation of the rms emittance can be overwhelmed by long tails in the simulated phase space distributions; more useful definitions of emittance are given. A complete simulation of the beamline is presented as well, which agrees with design specifications.

  2. FACET Emittance Growth

    International Nuclear Information System (INIS)

    Frederico, Joel

    2011-01-01

    FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration. The FACET beamline consists of a chicane and final focus system to compress the 23 GeV, 3.2 nC electron bunches to ∼20 (micro)m long and ∼10 (micro)m wide. Simulations of the FACET beamline indicate the short-duration and large, 1.5% rms energy spread beams may suffer a factor of four emittance growth from a combination of chromaticity, incoherent synchrotron radiation (ISR), and coherent synchrotron radiation (CSR). Emittance growth is directly correlated to head erosion in plasma wakefield acceleration and is a limiting factor in single stage performance. Studies of the geometric, CSR, and ISR components are presented. Numerical calculation of the rms emittance can be overwhelmed by long tails in the simulated phase space distributions; more useful definitions of emittance are given. A complete simulation of the beamline is presented as well, which agrees with design specifications.

  3. Instrumentation for the study of low emittance tuning and beam dynamics at CESR

    Science.gov (United States)

    Billing, M. G.; Dobbins, J. A.; Forster, M. J.; Kreinick, D. L.; Meller, R. E.; Peterson, D. P.; Ramirez, G. A.; Rendina, M. C.; Rider, N. T.; Sagan, D. C.; Shanks, J.; Sikora, J. P.; Stedinger, M. G.; Strohman, C. R.; Williams, H. A.; Palmer, M. A.; Holtzapple, R. L.; Flanagan, J.

    2017-11-01

    The Cornell Electron-positron Storage Ring (CESR) has been converted from a High Energy Physics electron-positron collider to operate as a dedicated synchrotron light source for the Cornell High Energy Synchrotron Source (CHESS) and to conduct accelerator physics research as a test accelerator, capable of studying topics relevant to future damping rings, colliders and light sources. Some of the specific topics that were targeted for the initial phase of operation of the storage ring in this mode for CESR as a Test Accelerator (CesrTA) included 1) tuning techniques to produce low emittance beams, 2) the study of electron cloud development in a storage ring and 3) intra-beam scattering effects. The complete conversion of CESR to CesrTA occurred over a several year period, described elsewhere [1-3]. In addition to instrumentation for the storage ring, which was created for CesrTA, existing instrumentation was modified to facilitate the entire range of investigations to support these studies. Procedures were developed, often requiring coordinated measurements among different instruments [4]. This paper describes the instruments utilized for the study of beam dynamics during the operation of CesrTA. The treatment of these instruments will remain fairly general in this paper as it focusses on an overview of the instruments themselves. Their interaction and inter-relationships during sequences of observations is found in a companion paper describing the associated measurement techniques. More detailed descriptions and detailed operational performance for some of the instrumentation may be found elsewhere and these will be referenced in the related sections of this paper.

  4. Feasibility Study of Silver as Emitter of In-core Neutron Detector

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Chi Dong; Lee, Hyun Suk [UNIST, Ulsan (Korea, Republic of); Shin, Ho Cheol; Cha, Kyoon Ho [Korea Hydro and Nuclear Power Corporation, Daejeon (Korea, Republic of); Lee, Deok Jung [UNIST, Ulsan (Korea, Republic of)

    2016-05-15

    The rhodium SPND(rhodium self-powered neutron detectors) provides strong detector signals so that they can be easily detected, but there is an issue the rhodium emitter needs to be replaced frequently because of its fast depletion. As an alternative, the vanadium SPND was designed and evaluated by Lee et al., but it also has an issue the detector signal level is too low. In this work, another material, silver, was introduced as emitter material of in-core detectors because its neutron absorption cross section is bigger than that of vanadium and smaller than rhodium. The feasibility of silver was investigated in comparison with the rhodium and vanadium detectors. The SPND model was designed using a Monte Carlo code MCNP6 and ORIGEN-S in SCALE code package. A silver self-powered neutron detector (SPND) was introduced in this paper, and the feasibility of silver as an emitter material of in-core detectors was investigated. The comparisons with rhodium and vanadium emitters demonstrate that silver has 0.78 years longer lifetime than rhodium and 10 times stronger signal than vanadium. Since a cycle length is generally 1.5 years, silver can be used for three cycles whereas rhodium should be replaced after two cycles.

  5. Asymmetrical field emitter

    Science.gov (United States)

    Fleming, J.G.; Smith, B.K.

    1995-10-10

    A method is disclosed for providing a field emitter with an asymmetrical emitter structure having a very sharp tip in close proximity to its gate. One preferred embodiment of the present invention includes an asymmetrical emitter and a gate. The emitter having a tip and a side is coupled to a substrate. The gate is connected to a step in the substrate. The step has a top surface and a side wall that is substantially parallel to the side of the emitter. The tip of the emitter is in close proximity to the gate. The emitter is at an emitter potential, and the gate is at a gate potential such that with the two potentials at appropriate values, electrons are emitted from the emitter. In one embodiment, the gate is separated from the emitter by an oxide layer, and the emitter is etched anisotropically to form its tip and its asymmetrical structure. 17 figs.

  6. Shielding in ungated field emitter arrays

    Energy Technology Data Exchange (ETDEWEB)

    Harris, J. R. [U.S. Navy Reserve, Navy Operational Support Center New Orleans, New Orleans, Louisiana 70143 (United States); Jensen, K. L. [Code 6854, Naval Research Laboratory, Washington, D.C. 20375 (United States); Shiffler, D. A. [Directed Energy Directorate, Air Force Research Laboratory, Albuquerque, New Mexico 87117 (United States); Petillo, J. J. [Leidos, Billerica, Massachusetts 01821 (United States)

    2015-05-18

    Cathodes consisting of arrays of high aspect ratio field emitters are of great interest as sources of electron beams for vacuum electronic devices. The desire for high currents and current densities drives the cathode designer towards a denser array, but for ungated emitters, denser arrays also lead to increased shielding, in which the field enhancement factor β of each emitter is reduced due to the presence of the other emitters in the array. To facilitate the study of these arrays, we have developed a method for modeling high aspect ratio emitters using tapered dipole line charges. This method can be used to investigate proximity effects from similar emitters an arbitrary distance away and is much less computationally demanding than competing simulation approaches. Here, we introduce this method and use it to study shielding as a function of array geometry. Emitters with aspect ratios of 10{sup 2}–10{sup 4} are modeled, and the shielding-induced reduction in β is considered as a function of tip-to-tip spacing for emitter pairs and for large arrays with triangular and square unit cells. Shielding is found to be negligible when the emitter spacing is greater than the emitter height for the two-emitter array, or about 2.5 times the emitter height in the large arrays, in agreement with previously published results. Because the onset of shielding occurs at virtually the same emitter spacing in the square and triangular arrays, the triangular array is preferred for its higher emitter density at a given emitter spacing. The primary contribution to shielding in large arrays is found to come from emitters within a distance of three times the unit cell spacing for both square and triangular arrays.

  7. Simulation study of electron cloud induced instabilities and emittance growth for the CERN Large Hadron Collider proton beam

    CERN Document Server

    Benedetto, Elena; Schulte, Daniel; Rumolo, Giovanni

    2005-01-01

    The electron cloud may cause transverse single-bunch instabilities of proton beams such as those in the Large Hadron Collider (LHC) and the CERN Super Proton Synchrotron (SPS). We simulate these instabilities and the consequent emittance growth with the code HEADTAIL, which models the turn-by-turn interaction between the cloud and the beam. Recently some new features were added to the code, in particular, electric conducting boundary conditions at the chamber wall, transverse feedback, and variable beta functions. The sensitivity to several numerical parameters has been studied by varying the number of interaction points between the bunch and the cloud, the phase advance between them, and the number of macroparticles used to represent the protons and the electrons. We present simulation results for both LHC at injection and SPS with LHC-type beam, for different electron-cloud density levels, chromaticities, and bunch intensities. Two regimes with qualitatively different emittance growth are observed: above th...

  8. A comparative study of the plasmon effect in nanoelectrode THz emitters: Pulse vs. continuous-wave radiation

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Kiwon; Lee, Eui Su; Lee, Il-Min; Han, Sang-Pil; Kim, Hyun-Soo; Park, Kyung Hyun, E-mail: khp@etri.re.kr [Terahertz Basic Research Section, Electronics and Telecommunications Research Institute (ETRI), Daejeon 305-700 (Korea, Republic of); Choi, Jeongyong [Metal-Insulator Transition Research Section, Electronics and Telecommunications Research Institute (ETRI), Daejeon 305-700 (Korea, Republic of); Lee, Donghun [Optical Internet Components Research Section, Electronics and Telecommunications Research Institute (ETRI), Daejeon 305-700 (Korea, Republic of)

    2016-08-15

    Plasmonic field enhancement in terahertz (THz) generation is one of the recently arisen techniques in the THz field that has attracted considerable interest. However, the reported levels of enhancement of THz output power in the literature are significantly different from each other, from less than two times to about two orders of magnitude of enhancement in power, which implies the existence of other major limiting factors yet to be revealed. In this work, the contribution of the plasmonic effect to the power enhancement of THz emitters is revisited. We show that the carrier collection efficiency in a THz emitter with plasmonic nanostructures is more critical to the device performance than the plasmonic field enhancement itself. The strong reverse fields induced by the highly localized plasmonic carriers in the vicinity of the nanoelectrodes screen the carrier collections and seriously limit the power enhancement. This is supported by our experimental observations of the significantly enhanced power in a plasmonic nanoelectrode THz emitter in continuous-wave radiation mode, while the same device has limited enhancement with pulsed radiation. We hope that our study may provide an intuitive but practical guideline in adopting plasmonic nanostructures with an aim of enhancing the efficiency of optoelectronic devices.

  9. Preliminary studies for the determination of alpha emitters using the gross alpha coprecipitation methods

    International Nuclear Information System (INIS)

    Suarez-Navarro, J. A.; Pujol, L.; Suarez, J. A.; Pablo, M. A. de

    2003-01-01

    The radiological quality of drinking water in Spain is regulated by Nuclear Security Guideline No, 7.7 (Rev.1) of the Nuclear Security Council (NSC). this guideline establishes the protocol to follow when the radiological level exceeds 0,1 Bq.l''1. When this level is passed, the responsible alpha emitter must be identified; ''210 Po, ''226Ra, ''230Th, ''239Pu, ''224Ra, ''234 U and ''138 U. Activity due to these isotopes is usually determined using alpha spectrometry with semiconductor detectors. This method allows the activity of the alpha emitters to be determined with a good sensitivity. however, it requires long radiochemical isolations and long counting times, so the method is not suitable for rough estimate radiological analysis. In this preliminary work, we present the conditioning of the sample-precipitate that is essential for further radiochemical isolations. (Author) 9 refs

  10. Impact of water temperature and structural parameters on the hydraulic labyrinth-channel emitter performance

    Directory of Open Access Journals (Sweden)

    Ahmed I. Al-Amoud

    2014-06-01

    Full Text Available The effects of water temperature and structural parameters of a labyrinth emitter on drip irrigation hydraulic performance were investigated. The inside structural parameters of the trapezoidal labyrinth emitter include path width (W and length (L, trapezoidal unit numbers (N, height (H, and spacing (S. Laboratory experiments were conducted using five different types of labyrinth-channel emitters (three non-pressure compensating and two pressure-compensating emitters commonly used for subsurface drip irrigation systems. The water temperature effect on the hydraulic characteristics at various operating pressures was recorded and a comparison was made to identify the most effective structural parameter on emitter performance. The pressure compensating emitter flow exponent (x average was 0.014, while non-pressure compensating emitter’s values average was 0.456, indicating that the sensitivity of non-pressure compensating emitters to pressure variation is an obvious characteristic (p<0.001 of this type of emitters. The effects of water temperature on emitter flow rate were insignificant (p>0.05 at various operating pressures, where the flow rate index values for emitters were around one. The effects of water temperature on manufacturer’s coefficient of variation (CV values for all emitters were insignificant (p>0.05. The CV values of the non-pressure compensating emitters were lower than those of pressure compensating emitters. This is typical for most compensating models because they are manufactured with more elements than non-compensating emitters are. The results of regression analysis indicate that N and H are the essential factors (p<0.001 to affect the hydraulic performance.

  11. Theoretical studies of thermionic conversion of solar energy with graphene as emitter and collector

    Science.gov (United States)

    Olawole, Olukunle C.; De, Dilip Kumar

    2018-01-01

    Thermionic energy conversion (TEC) using nanomaterials is an emerging field of research. It is known that graphene can withstand temperatures as high as 4600 K in vacuum, and it has been shown that its work function can be engineered from a high value (for monolayer/bilayer) of 4.6 eV to as low as 0.7 eV. Such attractive electronic properties (e.g., good electrical conductivity and high dielectric constant) make engineered graphene a good candidate as an emitter and collector in a thermionic energy converter for harnessing solar energy efficiently. We have used a modified Richardson-Dushman equation and have adopted a model where the collector temperature could be controlled through heat extraction in a calculated amount and a magnet can be attached on the back surface of the collector for future control of the space-charge effect. Our work shows that the efficiency of solar energy conversion also depends on power density falling on the emitter surface, and that a power conversion efficiency of graphene-based solar TEC as high as 55% can be easily achieved (in the absence of the space-charge effect) through proper choice of work functions, collector temperature, and emissivity of emitter surfaces. Such solar energy conversion would reduce our dependence on silicon solar panels and offers great potential for future renewable energy utilization.

  12. Dosimetry of internal emitters

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    The Dosimetry of Internal Emitter Program endeavors to refine the correlation between radiation dose and observed biological effects. The program is presently engaged in the development of studies that will demonstrate the applicability of microdosimetry models developed under the Microdosimetry of Internal Sources Program. The program also provides guidance and assistance to Pacific Northwest Laboratory's Biology Department in the dosimetric analysis of internally deposited radionuclides. This report deals with alpha particle dosimetry plutonium 239 inhalation, and in vitro studies of chromosomal observations

  13. Study of SPM tolerances of electronically compensated DML based systems.

    Science.gov (United States)

    Papagiannakis, I; Klonidis, D; Birbas, Alexios N; Kikidis, J; Tomkos, I

    2009-05-25

    This paper experimentally investigates the effectiveness of electronic dispersion compensation (EDC) for signals limited by self phase modulation (SPM) and various dispersion levels. The sources considered are low-cost conventional directly modulated lasers (DMLs), fabricated for operation at 2.5 Gb/s but modulated at 10 Gb/s. Performance improvement is achieved by means of electronic feed-forward and decision-feedback equalization (FFE/DFE) at the receiver end. Experimental studies consider both transient and adiabatic chirp dominated DMLs sources. The improvement is evaluated in terms of required optical signal-to-noise ratio (ROSNR) for bit-error-rate (BER) values of 10(-3) versus launch power over uncompensated links of standard single mode fiber (SSMF).

  14. Spherical proton emitters

    International Nuclear Information System (INIS)

    Berg, S.; Semmes, P.B.; Nazarewicz, W.

    1997-01-01

    Various theoretical approaches to proton emission from spherical nuclei are investigated, and it is found that all the methods employed give very similar results. The calculated decay widths are found to be qualitatively insensitive to the parameters of the proton-nucleus potential, i.e., changing the potential parameters over a fairly large range typically changes the decay width by no more than a factor of ∼3. Proton half-lives of observed heavy proton emitters are, in general, well reproduced by spherical calculations with the spectroscopic factors calculated in the independent quasiparticle approximation. The quantitative agreement with experimental data obtained in our study requires that the parameters of the proton-nucleus potential be chosen carefully. It also suggests that deformed proton emitters will provide invaluable spectroscopic information on the angular momentum decomposition of single-proton orbitals in deformed nuclei. copyright 1997 The American Physical Society

  15. Nanodiamond Emitters of Single Photons

    Directory of Open Access Journals (Sweden)

    Vlasov I.I.

    2015-01-01

    Full Text Available Luminescence properties of single color centers were studied in nanodiamonds of different origin. It was found that single photon emitters could be realized even in molecularsized diamond (less than 2 nm capable of housing stable luminescent center “silicon-vacancy.” First results on incorporation of single-photon emitters based on luminescent nanodiamonds in plasmonic nanoantennas to enhance the photon count rate and directionality, diminish the fluorescence decay time, and provide polarization selectivity are presented.

  16. Emittance control and RF bunch compression in the NSRRC photoinjector

    International Nuclear Information System (INIS)

    Lau, W.K.; Hung, S.B.; Lee, A.P.; Chou, C.S.; Huang, N.Y.

    2011-01-01

    The high-brightness photoinjector being constructed at the National Synchrotron Radiation Research Center is for testing new accelerator and light-source concepts. It is the so-called split photoinjector configuration in which a short solenoid magnet is used for emittance compensation. The UV-drive laser pulses are also shaped to produce uniform cylindrical bunches for further reduction of beam emittance. However, limited by the available power from our microwave power system, the nominal accelerating gradient in the S-band booster linac is set at 18 MV/m. A simulation study with PARMELA shows that the linac operating at this gradient fails to freeze the electron beam emittance at low value. A background solenoid magnetic field is applied for beam emittance control in the linac during acceleration. A satisfactory result that meets our preliminary goal has been achieved with the solenoid magnetic field strength at 0.1 T. RF bunch compression as a means to achieve the required beam brightness for high-gain free-electron laser experiments is also examined. The reduction of bunch length to a few hundred femtoseconds can be obtained.

  17. Emittance study of a 28 GHz electron cyclotron resonance ion source for the Rare Isotope Science Project superconducting linear accelerator.

    Science.gov (United States)

    Park, Bum-Sik; Hong, In-Seok; Jang, Ji-Ho; Jin, Hyunchang; Choi, Sukjin; Kim, Yonghwan

    2016-02-01

    A 28 GHz electron cyclotron resonance (ECR) ion source is being developed for use as an injector for the superconducting linear accelerator of the Rare Isotope Science Project. Beam extraction from the ECR ion source has been simulated using the KOBRA3-INP software. The simulation software can calculate charged particle trajectories in three dimensional complex magnetic field structures, which in this case are formed by the arrangement of five superconducting magnets. In this study, the beam emittance is simulated to understand the effects of plasma potential, mass-to-charge ratio, and spatial distribution. The results of these simulations and their comparison to experimental results are presented in this paper.

  18. Production of positron emitters of metallic elements to study plant uptake and distribution

    International Nuclear Information System (INIS)

    Watanabe, S.; Ishioka, N.S.; Sekine, T.; Osa, A.; Koizumi, M.; Kiyomiya, S.; Nakanishi, H.; Mori, S.

    2001-01-01

    The metallic positron emitters 52 Mn, 52 Fe and 62 Zn, the elements of which are essential nutrients for plants as well as for animals, have been produced for a new tracer method in plant physiology. The tracer method utilizes the detection of annihilation γ-rays, like PET in nuclear medicine, to obtain two-dimensional images on a plant as well as to obtain radioactivity counts at specified points in a plant; this method allows us to observe the tracer movement in a living plant without touching the test plant. The previously reported methods of radiochemical separation of these metallic positron emitters from targets were partly modified from the view of their use in plant physiology. Radionuclidic impurities remaining in the final solutions were examined by γ-ray spectrometry, and their influences on the above-mentioned measurements are discussed. From the experiments on a barley plant, the speeds of 52 Mn 2+ ion and 52 Fe 3+ - mugineic-acid complex have been obtained for the first time to be 0.2 cm/min and 1.0 cm/min, respectively. (orig.)

  19. Emittance control in linear colliders

    International Nuclear Information System (INIS)

    Ruth, R.D.

    1991-01-01

    Before completing a realistic design of a next-generation linear collider, the authors must first learn the lessons taught by the first generation, the SLC. Given that, they must make designs fault tolerant by including correction and compensation in the basic design. They must also try to eliminate these faults by improved alignment and stability of components. When these two efforts cross, they have a realistic design. The techniques of generation and control of emittance reviewed here provide a foundation for a design which can obtain the necessary luminosity in a next-generation linear collider

  20. Skills and compensation strategies in adult ADHD - A qualitative study.

    Science.gov (United States)

    Canela, Carlos; Buadze, Anna; Dube, Anish; Eich, Dominique; Liebrenz, Michael

    2017-01-01

    The primary objectives of this study were to investigate how adult patients with ADHD coped with their symptoms prior to diagnosis and treatment, what skills and compensation strategies they had developed and what their self-perceptions of these strategies were. We used a qualitative approach to analyze interviews with 32 outpatients of a specialty care unit at a university hospital. Patients reported frequent use of diverse compensatory strategies with varying degrees of effectiveness. These were classified into five categories (organizational, motoric, attentional, social, psychopharmacological). In certain circumstances, ADHD symptoms were even perceived as useful. Before diagnosis and treatment, patients with ADHD may develop a variety of skills to cope with their symptoms. Several of these skills are perceived as helpful. Knowledge of self-generated coping strategies may help better understand patients and their histories and thus facilitate patient cooperation. Moreover, knowing ways in which such patients cope with their symptoms may help elucidate reasons for late or under-diagnosing of the disorder.

  1. Study of plasmonics in hybrids made from a quantum emitter and double metallic nanoshell dimer

    Science.gov (United States)

    Guo, Jiaohan; Black, Kevin; Hu, Jiawen; Singh, Mahi

    2018-05-01

    We developed a theory for the fluorescence (FL) for quantum emitter and double metallic nanoshell dimer hybrids using the density matrix method. The dimer is made from two identical double metallic nanoshells, which are made of a dielectric core, a gold metallic shell and a dielectric spacer layer. The quantum emitters are deposited on the surface of the spacer layers of the dimers due to the electrostatic absorptions. We consider that dimer hybrids are surrounded by biological cells. This can be achieved by injecting them into human or animal cells. The surface plasmon polaritons (SPP) are calculated for the dimer using Maxwell’s equations in the static wave approximation. The calculated SPP energy agrees with experimental data from Zhai et al (2017 Plasmonics 12 263) for the dimer made from a silica core, a gold metallic nanoshell and a silica spacer layer. We have also obtained an analytical expression of the FL using the density matrix method. We compare our theory with FL experimental data from Zhai et al (2017 Plasmonics 12 263) where the FL spectrum was measured by varying the thickness of the spacer layer from 9 nm to 40 nm. A good agreement between theory and experiment is found. We have shown that the enhancement of the FL increases as the thickness of the spacer layer decreases. We have also found that the enhancement of the FL increases as the distance between the double metallic nanoshells in the dimer decreases. These are interesting findings which are consistent with the experiments of Zhai et al (2017 Plasmonics 12 263) and can be used to control the FL enhancement in the FL-based biomedical imaging and cancer treatment. These interesting findings may also be useful in the fabrication of nanosensors and nanoswitches for applications in medicine.

  2. Study on Compensation Control of STATCOM Based on MMC

    Directory of Open Access Journals (Sweden)

    Xie Yan

    2016-01-01

    Full Text Available This paper introduced modular multi-level converter (MMC, which could enhance the voltage and power level by sub-converter modules in series and was easy to extend to any level of output. Its structure and working mechanism were described. By analyzing the energy transfer performance of STATCOM based on MMC working conditions in the compensation, a comprehensive compensation control strategy was proposed based on direct current control mode. By analyzing the higher harmonic components circulation generated by the inconsistencies in the three-phase upper and lower arm voltage, a loop control strategy is proposed for the suppression of the circulation in the arms of the M-STATCOM. The simulation results show the strategy has a better tracking precision and response speed for the compensation control.

  3. Bent solenoids for spectrometers and emittance exchange sections

    International Nuclear Information System (INIS)

    Norem, J.

    1999-01-01

    Bent solenoids can be used to transport low energy beams as they provide both confinement and dispersion of particle orbits. Solenoids are being considered both as emittance exchange sections and spectrometers in the muon cooling system as part of the study of the muon collider. They present the results of a study of bent solenoids which considers the design of coupling sections between bent solenoids to straight solenoids, drift compensation fields, aberrations, and factors relating to the construction, such as field ripple, stored energy, coil forces and field errors

  4. Emittance Growth in the NLCTA First Chicane

    International Nuclear Information System (INIS)

    Sun, Yipeng

    2011-01-01

    In this paper, the emittance growth in the NLCTA (Next Linear Collider Test Accelerator) first chicane region is evaluated by simulation studies. It is demonstrated that the higher order fields of the chicane dipole magnet and the dipole corrector magnet (which is attached on the quadrupoles) are the main contributions for the emittance growth, especially for the case with a large initial emittance (γε 0 = 5 (micro)m for instance). These simulation results agree with the experimental observations.

  5. Quantum efficiency and thermal emittance of metal photocathodes

    Directory of Open Access Journals (Sweden)

    David H. Dowell

    2009-07-01

    Full Text Available Modern electron beams have demonstrated the brilliance needed to drive free electron lasers at x-ray wavelengths with major advances occurring since the invention of the photocathode gun and the realization of emittance compensation. These state-of-the-art electron beams are now becoming limited by the intrinsic thermal emittance of the cathode. In both dc and rf photocathode guns details of the cathode emission physics strongly influence the quantum efficiency and the thermal emittance. Therefore improving cathode performance is essential to increasing the brightness of beams. It is especially important to understand the fundamentals of cathode quantum efficiency and thermal emittance. This paper investigates the relationship between the quantum efficiency and the thermal emittance for metal cathodes using the Fermi-Dirac model for the electron distribution. We use a consistent theory to derive the quantum efficiency and thermal emittance, and compare our results to those of others.

  6. Hydration of mineral shrinkage-compensating admixture for concrete : an experimental and numerical study

    NARCIS (Netherlands)

    Chen, Wei; Brouwers, H.J.H.

    2012-01-01

    The use of shrinkage-compensating admixture in concrete has been proven to be an effective way to mitigate the shrinkage of concrete. The hydration of a shrinkage-compensating admixture in cement paste and concrete is investigated in this paper with numerical simulation and experimental study. An

  7. Caloric compensation for sugar-sweetened beverages in meals: A population-based study in Brazil.

    Science.gov (United States)

    Gombi-Vaca, Maria Fernanda; Sichieri, Rosely; Verly, Eliseu

    2016-03-01

    Sugar-sweetened beverage (SSB) consumption can cause positive energy balance, therefore leading to weight gain. A plausible biological mechanism to explain this association is through weak caloric compensation for liquid calories. However, there is an ongoing debate surrounding SSB calorie compensation. The body of evidence comes from a diversity of study designs and highly controlled settings assessing food and beverage intake. Our study aimed to test for caloric compensation of SSB in the free-living setting of daily meals. We analyzed two food records of participants (age 10 years or older) from the 2008-2009 National Dietary Survey (Brazil, N = 34,003). We used multilevel analyses to estimate the within-subject effects of SSB on food intake. Sugar-sweetened beverage calories were not compensated for when comparing daily energy intake over two days for each individual. When comparing meals, we found 42% of caloric compensation for breakfast, no caloric compensation for lunch and zero to 22% of caloric compensation for dinner, differing by household per capita income. In conclusion, SSB consumption contributed to higher energy intake due to weak caloric compensation. Discouraging the intake of SSB especially during lunch and dinner may help reduce excessive energy intake and lead to better weight management. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Preliminary study on the analysis of alpha emitters at working places in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hanna; Kim, Jeong In; Lee, Byoungil [Korea Hydro and Nuclear Power Co., Seoul (Korea, Republic of); Yoon, Suk Won [Korea Institute of Radiological and Medical Sciences National Radiation Emergency Medical Center, Seoul (Korea, Republic of)

    2012-10-15

    Over sea nuclear power plants have been reported cases of internal contamination by alpha nuclides. In many cases, stations encountered significant alpha contamination when aged/legacy equipment was disturbed or handled. Under normal operating conditions, transuranic radionuclides are contained within the fuel rods and therefore are not a contributor to radioactive contamination within a facility. However, transuranic radionuclides result from the presence of tramp-uranium contamination on the exterior of fuel elements. Fuel failures may develop during operating cycles due to a variety of causes, ranging from manufacturing defects to mechanical or abrasive damage. In case of domestic nuclear power plants, the pressure tube replacements in Wolsong Unit 1 and steam generator replacements in Kori Unit 1 were done. Due to deterioration of equipment in accordance with the long-term operation, the domestic nuclear power plants are expected to improve the facilities and the probability of internal exposure from alpha emitters is increasing. The domestic nuclear power plants are only keeping alpha radionuclides of the effluent from the exterior under constant surveillance. The representative areas of CV are just carried out continuous alpha monitoring in during a unit outage. So far, there is no other case with alpha nuclides analysis. As the domestic nuclear power plants are expected to improve the facilities, it is the time to take proactive measures to deal with internal contamination by alpha emitting radioactive elements. In this paper, the possible risk of internal exposure is based on preliminary experiments on the analysis of alpha emitting radioactive elements at working places in nuclear power plants.

  9. A study on tissue compensator thickness ratio and an application for 4MV X-rays

    International Nuclear Information System (INIS)

    Kim, Young Bum; Kwon, Young Ho; Jung, Hee Young; Kim, You Hyun

    1996-01-01

    A radiation beam incident on irregular or sloping surface produces an inhomogeneity of absorbed dose. The use of a tissue compensator can partially correct this dose inhomogeneity. The tissue compensator should be made based on experimentally measured thickness ratio. The thickness ratio depends on beam energy, distance from the tissue compensator to the surface of patient, field size, treatment depth, tissue deficit and other factors. In this study, the thickness ratio was measured for various field size of 5cm x 5cm, 10cm x 10cm, 15cm x 15cm, 20 x 20cm for 4MV X-ray beams. The distance to the compensator from the X-ray target was fixed, 49cm, and measurement depth was 3, 5, 7, 9 cm. For each measurement depth, the tissue deficit was changed from 0 to(measurement depth-1)cm by 1cm increment. As a result, thickness ratio was decreased according to field size and tissue deficit was increased. Use of a representative thickness ratio for tissue compensator, there was 10% difference of absorbed dose but use of a experimentally measured thickness ratio for tissue compensator, there was 2% difference of absorbed dose. Therefore, it can be concluded that the tissue compensator made by experimentally measured thickness ratio can produce good distribution with acceptable inhomogeneity and such tissue compensator can be effectively applied to clinical radiotherapy.

  10. Study on the risk of late damage in humans after incorporation of the short-lived alpha emitter Ra-224

    International Nuclear Information System (INIS)

    Wick, R.R.; Nekolla, E.A.; Kellerer, A.M.; Goessner, W.

    2003-01-01

    An epidemiological study has been carried out at the GSF - National Research Center for Environment and Health - between 1948 and 1975, on 1460 ankylosing spondylitis (AS) patients. The aim of the study was to ascertain the late health effects suffered by these patients who had received repeated intravenous injections of the short lived α-emitter 224 Ra. These patients have been followed together with a control group of 1323 ankylosing spondylitis patients not treated with radioactive drugs and/or X-rays. Causes of death have been ascertained for 842 exposed patients and 861 controls by the end of 2002. In the exposed group there has been a total of 219 malignant diseases and 206 cases among the controls. In particular, we observed 15 cases of leukaemia in the exposure group and 8 cases of leukaemia in the control group. Further subclassification of the leukaemias demonstrated a high increase of myeloid leukaemia in the exposure group (9 cases obs. vs. 2.5 cases exp.), and out of these especially the acute myeloid leukaemias (6 cases observed vs. 1.6 expected), whereas in the control group the observed cases are within the expected range (3 myeloid leukaemias vs. 2.6 cases). Out of these 6 cases of myeloid leukaemia, 3 cases have been observed at doses comparable to those of the currently applied 224 Ra treatment with the preparation SpondylAT registered , in one case the 224 Ra-dose was the 0.6fold, in another case 1.6fold, whereas in one case the total dose could not be verified exactly. The enhanced leukaemia incidence in our exposed group is in line with results from animal experiments in mice having been injected with bone seeking α-emitters given at low dose rates. (orig.) [de

  11. Beam phase space and emittance

    International Nuclear Information System (INIS)

    Buon, J.

    1992-02-01

    The classical and elementary results for canonical phase space, the Liouville theorem and the beam emittance are reviewed. Then, the importance of phase portraits to obtain a geometrical description of motion is emphasized, with examples in accelerator physics. Finally, a statistical point of view is used to define beam emittance, to study its law of approximate conservation, with three particular examples, and to introduce a beam envelope-ellipse and the β-function, emphasing the statistical features of its properties. (author) 14 refs.; 11 figs

  12. Veterans affairs disability compensation: a case study in countertherapeutic jurisprudence.

    Science.gov (United States)

    Mossman, D

    1996-01-01

    This article examines the disability compensation programs and health care system of the Department of Veterans Affairs (VA) from the perspective of therapeutic jurisprudence scholarship. VA psychiatric patients have unambiguous financial incentives to endlessly litigate disability claims, to seek lengthy hospitalization rather than outpatient treatment, and to be ill, disabled, and unemployed. These countertherapeutic incentives reward incapacitation, encourage perceiving one-self as sick, diminish personal responsibility, taint treatment relationships, and lead to disparaging perceptions of VA patients. In addition, such perceptions produce moral dilemmas that arise from mutual distrust and frustration when patients and caregivers have antagonistic goals for the clinical encounter. Changes in disability determination procedures, compensation levels, and patterns of payment for treatment could give VA patients and caregivers a "healthier" health care system that encourages personal responsibility and promotes respectful attitudes toward patients. In the absence of such changes, an awareness of countertherapeutic financial incentives can help clinicians distinguish between psychopathological behavior and the pursuit of a rational income strategy, and can help practitioners recognize that apparently deceitful or litigious behavior represents a reasonable response to the economic contingencies that VA patients face.

  13. Motion-compensating gradients in the study of multiple sclerosis

    International Nuclear Information System (INIS)

    Runge, V.M.; Wood, M.L.; Kaufman, D.L.

    1987-01-01

    A low bandwidth motion compensating technique (no. 1) was compared with a conventional spin-echo technique (no. 2) in 20 patients with multiple sclerosis using a 1.0-T MR imaging system. In technique 1, refocusing gradients were employed to compensate for motion of constant velocity along the frequency-encoding direction. The sampling time was also increased to provide a greater S/N. Use of technique 1 was resulted in detection of 42% +- 23% more lesions (n = 8). The contrast-to-noise ratio for gray versus white matter improved by 87% +- 54% and that for lesion versus white matter by 66% +- 22%. The S/N for white matter improved by 56% +- 25%. An increase in chemical shift artifact was noted but not felt to be detrimental to lesion visualization. In the majority of cases, normal brain stem structures were more distinctly visualized. In two cases, pontine lesions were more clearly demarcated due to reduced pulsation artifacts. The combined use of refocusing gradients and low bandwidth techniques provides reduction of motion artifacts (from CSF and vessel pulsation) and improved S/N, leading to improved lesion detection

  14. Performance Evaluations and Victim Satisfaction With State Compensation for Violent Crime: A Prospective Study.

    Science.gov (United States)

    Kunst, M J J; Koster, N N; Van Heugten, J

    2015-07-29

    Satisfaction with a particular good or service represents an affective state in response to an individual's evaluation of the performance of that good or service. This evaluation involves a comparison between perceived actual performance and prior expectations. The current study used this theoretical idea to study violent crime victims' levels of satisfaction with services provided by a Dutch state compensation scheme. One hundred and seventy-seven victims of violent crime who had applied for compensation from the Dutch Violent Offences Compensation Fund (DVOCF) participated in two brief telephone interviews: one before receipt of the fund's decision upon their request for compensation and one after receipt of that decision. Based on the theories of distributive and procedural justice, measurement of prior expectations was differentiated in expectations about receipt of compensation, treatment by fund workers, and information provision. Results suggested that satisfaction with the DVOCF depended on fulfillment of expectations about treatment by fund workers and information provision, but not on fulfillment of expectations about receipt of compensation. Other predictors of victim satisfaction were as follows: duration of the application procedure, approval upon request for compensation, and satisfaction assessed during the first interview. Results were discussed in light of theory, policy implications, study limitations, and future research. © The Author(s) 2015.

  15. Coupling single emitters to quantum plasmonic circuits

    DEFF Research Database (Denmark)

    Huck, Alexander; Andersen, Ulrik Lund

    2016-01-01

    In recent years, the controlled coupling of single-photon emitters to propagating surface plasmons has been intensely studied, which is fueled by the prospect of a giant photonic nonlinearity on a nanoscaled platform. In this article, we will review the recent progress on coupling single emitters...

  16. Studies on compensating valency substituted BaTi (Mnx/2Nbx/2O3 ...

    Indian Academy of Sciences (India)

    Studies on compensating valency substituted BaTi(1-)Mn/2Nb/2O3 ceramics ... Annealing is observed to improve quality factor `' of the materials with a ... material engineering efforts are required to improve the material properties.

  17. An experimental study on the effects of swirling oxidizer flow and diameter of fuel nozzle on behaviour and light emittance of propane-oxygen non-premixed flame

    Directory of Open Access Journals (Sweden)

    Javareshkian Alireza

    2017-01-01

    Full Text Available In this study, the stability and the light emittance of non-premixed propane-oxygen flames have been experimentally evaluated with respect to swirling oxidizer flow and variations in fuel nozzle diameter. Hence, three types of the vanes with the swirl angles of 30°, 45°, and 60° have been chosen for producing the desired swirling flows. The main aims of this study are to determine the flame behaviour, light emittance, and also considering the effect of variation in fuel nozzle diameter on combustion phenomena such as flame length, flame shape, and soot free length parameter. The investigation into the flame phenomenology was comprised of variations of the oxidizer and fuel flow velocities (respective Reynolds numbers and the fuel nozzle diameter. The results showed that the swirl effect could change the flame luminosity and this way could reduce or increase the maximum value of the flame light emittance in the combustion zone. Therefore, investigation into the flame light emittance can give a good clue for studying the mixing quality of reactants, the flame phenomenology (blue flame or sooty flame, localized extinction, and the combustion intensity in non-premixed flames.

  18. Compensation phenomena of a mixed spin-2 and spin-12 Heisenberg ferrimagnetic model: Green function study

    International Nuclear Information System (INIS)

    Li Jun; Wei Guozhu; Du An

    2005-01-01

    The compensation and critical behaviors of a mixed spin-2 and spin-12 Heisenberg ferrimagnetic system on a square lattice are investigated theoretically by the two-time Green's function technique, which takes into account the quantum nature of Heisenberg spins. The model can be relevant for understanding the magnetic behavior of the new class of organometallic ferromagnetic materials that exhibit spontaneous magnetic properties at room temperature. We carry out the calculation of the sublattice magnetizations and the spin-wave spectra of the ground state. In particular, we have studied the effects of the nearest, next-nearest-neighbor interactions, the crystal field and the external magnetic field on the compensation temperature and the critical temperature. When only the nearest-neighbor interactions and the crystal field are included, no compensation temperature exists; when the next-nearest-neighbor interaction between spin-12 is taken into account and exceeds a minimum value, a compensation point appears and it is basically unchanged for other parameters in Hamiltonian fixed. The next-nearest-neighbor interactions between spin-2 and the external magnetic field have the effects of changing the compensation temperature and there is a narrow range of parameters of the Hamiltonian for which the model has the compensation temperatures and compensation temperature exists only for a small value of them

  19. Emittance measurements of the CLIO electron beam

    Science.gov (United States)

    Chaput, R.; Devanz, G.; Joly, P.; Kergosien, B.; Lesrel, J.

    1997-02-01

    We have designed a setup to measure the transverse emittance at the CLIO accelerator exit, based on the "3 gradients" method. The beam transverse size is measured simply by scanning it with a steering coil across a fixed jaw and recording the transmitted current, at various quadrupole strengths. A code then performs a complete calculation of the emittance using the transfer matrix of the quadrupole instead of the usual classical lens approximation. We have studied the influence of various parameters on the emittance: Magnetic field on the e-gun and the peak current. We have also improved a little the emittance by replacing a mismatched pipe between the buncher and accelerating section to avoid wake-field effects; The resulting improvements of the emittance have led to an increase in the FEL emitted power.

  20. An Experimental Study of the Accuracy of Compensation in Lithium Drifted Germanium Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Lauber, A; Malmsten, B

    1969-10-15

    The nature and magnitude of the space charge existing in the compensated layer of lithium drifted germanium detectors has been studied as a function of drifted depth and of the electric field applied during drift. Experimental values were obtained from the dependence of detector capacitance on applied bias. In most cases there was a linear space charge gradient in the compensated layer. When small electric fields were applied to deep compensated layers, the space charge became constant throughout a large part of the compensated layer. There is some evidence for a strong decrease of mobile carrier recombination lifetime with increasing drifted depth, possibly down to a few microseconds for drifted depths of the order of 7 mm. The experimental results of the investigation are to a large extent in good agreement with theory.

  1. Ecological Compensation Mechanism in Water Conservation Area: A Case Study of Dongjiang River

    Directory of Open Access Journals (Sweden)

    Kong Fanbin

    2015-07-01

    Full Text Available The appropriate economic compensation from downstream to upstream watershed is important to solve China’s social and economic imbalances between regions and can potentially enhance water resources protection and ecological security. The study analyzes the implementation of ecological compensation policy and related legal basis under ecological compensation mechanism theory and practice patterns, based on current natural environment and socio-economic development of national origin in Dongjiang water conservation areas. Under the principle of “Users pay”, the Dongjiang River is the subject of ecological compensation and recipient. By using the “cost-benefit analysis” and “cost method of industrial development opportunity”, we estimate that the total ecological compensation amounted to 513.35 million yuan. When estimated by the indicators such as water quantity, water quality and water use efficiency, we establish the “environmental and ecological protection cost sharing model” and measure the total cost of protecting downstream watershed areas, the Guangdong Province, is about 108.61 million yuan. The implementation of the Dongjiang source region that follows the principles of ecological compensation and approaches are also designed

  2. Differences in perceived fairness and health outcomes in two injury compensation systems: a comparative study.

    Science.gov (United States)

    Elbers, Nieke A; Collie, Alex; Hogg-Johnson, Sheilah; Lippel, Katherine; Lockwood, Keri; Cameron, Ian D

    2016-07-29

    Involvement in a compensation process following a motor vehicle collision is consistently associated with worse health status but the reasons underlying this are unclear. Some compensation systems are hypothesised to be more stressful than others. In particular, fault-based compensation systems are considered to be more adversarial than no-fault systems and associated with poorer recovery. This study compares the perceived fairness and recovery of claimants in the fault-based compensation system in New South Wales (NSW) to the no-fault system in Victoria, Australia. One hundred eighty two participants were recruited via claims databases of the compensation system regulators in Victoria and NSW. Participants were > 18 years old and involved in a transport injury compensation process. The crash occurred 12 months (n = 95) or 24 months ago (n = 87). Perceived fairness about the compensation process was measured by items derived from a validated organisational justice questionnaire. Health outcome was measured by the initial question of the Short Form Health Survey. In Victoria, 84 % of the participants considered the claims process fair, compared to 46 % of NSW participants (χ(2) = 28.54; p < .001). Lawyer involvement and medical assessments were significantly associated with poorer perceived fairness. Overall perceived fairness was positively associated with health outcome after adjusting for demographic and injury variables (Adjusted Odds Ratio = 2.8, 95 % CI = 1.4 - 5.7, p = .004). The study shows large differences in perceived fairness between two different compensation systems and an association between fairness and health. These findings are politically important because compensation processes are designed to improve recovery. Lower perceived fairness in NSW may have been caused by potential adversarial aspects of the scheme, such as liability assessment, medical assessments, dealing with a third party for-profit insurance

  3. Differences in perceived fairness and health outcomes in two injury compensation systems: a comparative study

    Directory of Open Access Journals (Sweden)

    Nieke A. Elbers

    2016-07-01

    Full Text Available Abstract Background Involvement in a compensation process following a motor vehicle collision is consistently associated with worse health status but the reasons underlying this are unclear. Some compensation systems are hypothesised to be more stressful than others. In particular, fault-based compensation systems are considered to be more adversarial than no-fault systems and associated with poorer recovery. This study compares the perceived fairness and recovery of claimants in the fault-based compensation system in New South Wales (NSW to the no-fault system in Victoria, Australia. Methods One hundred eighty two participants were recruited via claims databases of the compensation system regulators in Victoria and NSW. Participants were > 18 years old and involved in a transport injury compensation process. The crash occurred 12 months (n = 95 or 24 months ago (n = 87. Perceived fairness about the compensation process was measured by items derived from a validated organisational justice questionnaire. Health outcome was measured by the initial question of the Short Form Health Survey. Results In Victoria, 84 % of the participants considered the claims process fair, compared to 46 % of NSW participants (χ2 = 28.54; p < .001. Lawyer involvement and medical assessments were significantly associated with poorer perceived fairness. Overall perceived fairness was positively associated with health outcome after adjusting for demographic and injury variables (Adjusted Odds Ratio = 2.8, 95 % CI = 1.4 – 5.7, p = .004. Conclusion The study shows large differences in perceived fairness between two different compensation systems and an association between fairness and health. These findings are politically important because compensation processes are designed to improve recovery. Lower perceived fairness in NSW may have been caused by potential adversarial aspects of the scheme, such as liability assessment, medical

  4. Studies of emittance growth and halo particle production in intense charged particle beams using the Paul Trap Simulator Experiment

    International Nuclear Information System (INIS)

    Gilson, Erik P.; Davidson, Ronald C.; Dorf, Mikhail; Efthimion, Philip C.; Majeski, Richard; Chung, Moses; Gutierrez, Michael S.; Kabcenell, Aaron N.

    2010-01-01

    The Paul Trap Simulator Experiment (PTSX) is a compact laboratory experiment that places the physicist in the frame-of-reference of a long, charged-particle bunch coasting through a kilometers-long magnetic alternating-gradient (AG) transport system. The transverse dynamics of particles in both systems are described by the same set of equations, including nonlinear space-charge effects. The time-dependent voltages applied to the PTSX quadrupole electrodes in the laboratory frame are equivalent to the spatially periodic magnetic fields applied in the AG system. The transverse emittance of the charge bunch, which is a measure of the area in the transverse phase space that the beam distribution occupies, is an important metric of beam quality. Maintaining low emittance is an important goal when defining AG system tolerances and when designing AG systems to perform beam manipulations such as transverse beam compression. Results are reviewed from experiments in which white noise and colored noise of various amplitudes and durations have been applied to the PTSX electrodes. This noise is observed to drive continuous emittance growth and increase in root-mean-square beam radius over hundreds of lattice periods. Additional results are reviewed from experiments that determine the conditions necessary to adiabatically reduce the charge bunch's transverse size and simultaneously maintain high beam quality. During adiabatic transitions, there is no change in the transverse emittance. The transverse compression can be achieved either by a gradual change in the PTSX voltage waveform amplitude or frequency. Results are presented from experiments in which low emittance is achieved by using focusing-off-defocusing-off waveforms.

  5. A study of creep behavior in refractory alloys for thermionic emitter applications

    International Nuclear Information System (INIS)

    Gao Hong; Zee, Ralph

    1997-01-01

    The creep behavior of HfC strengthened tungsten alloys was studied. An ultrahigh vacuum high precision creep test system was constructed for this purpose so that the samples could be heated up to 3000 K for heat treatment and creep strain could be measured from the creep sample inside the vacuum chamber. Creep tests were conducted in tungsten strengthened with 0.37 percent of HfC at temperatures between 2000 K to 2500 K for durations up to 8 weeks. To explain the creep behavior observed in this dispersion strengthened alloy, a creep model was proposed which accounted for the presence of HfC particles in the form of a back stress generated by these particles. This model was verified by the creep test data of a W-0.37HfC alloy tested under both extruded and recrystallized microstructural conditions. According to this model, the steady state creep of this type alloys was expected to increase with time due to the HfC particle coarsening and recrystallization under high temperatures. In contrast, conventional simple power law creep only predicts a constant steady state creep for these materials, which does not represent the microstructural evolution of the materials. In this study, the experimental study was designed to verify the semi-mechanistic phenomenological creep model developed for carbide particle strengthened tungsten alloys

  6. Gold-195m short-lived single-photon emitter for cardiovascular studies

    International Nuclear Information System (INIS)

    Mena, I.; de Jong, R.; Mena, F.J.; Narahara, K.A.

    1985-01-01

    Ultrashort-lived radionuclides offer many advantages for clinical nuclear medicine. These radionuclide are generator-produced at bedside, with markedly diminished radiation exposure to the patient; larger doses of radionuclides can therefore be administered, and rapid, sequential, background-free studies can be performed. Gold-195m is an example of an ultrashort-lived radionuclide with a half-life of 30.4 sec. It is generated from /sup 195m/Hg (T/sub 1/2/, 40.6 hr). The quality of imaging and radiation exposure to patients is a function of the percentage breakthrough of /sup 195m/Hg owing to high-energy gamma radiation and longer half-life. Percentage breakthrough of /sup 195m/Hg was measured. The performance of the generator was assessed by determining the coefficient of variation of subsequent measurements

  7. Socioeconomic outcomes following spinal cord injury and the role of no-fault compensation: longitudinal study.

    Science.gov (United States)

    Paul, C; Derrett, S; McAllister, S; Herbison, P; Beaver, C; Sullivan, M

    2013-12-01

    Longitudinal cohort study. To estimate socioeconomic and work outcomes over 2 and a half years following spinal cord injury (SCI), and to compare those in receipt of compensation (Accident Compensation Corporation, ACC) and those not. People admitted to the two spinal units in 2007-2009 in New Zealand, where there is a unique no-fault compensation scheme for injury. Interviews were conducted at ∼6, 18 and 30 months after SCI and data collected on pre-SCI and post-SCI health and socioeconomic characteristics. Poisson regression, quantile regression and a linear mixed model regression were used to compare differences in outcomes. Of the 162 eligible people, 118 (73%) participated and 91(77%) were followed to 30 months; 79% received ACC. Median personal income, self-reported standard of living and household income adequacy all fell slightly to 18 months and then stabilized at 30 months. At that time, 49% had returned to paid work. Among those not eligible for ACC, income fell to less than half the ACC group (Pretained their economic status and that return to work was relatively high appear to be due to the proportion entitled to the ACC no-fault compensation scheme for injury; with earnings-related compensation, a focus on rehabilitation to work and non-means-tested support services. This situation should mitigate against the downward spiral into poverty and further ill-health.

  8. High topographic resolution for the study of micro-distribution of alpha-emitters in bones

    International Nuclear Information System (INIS)

    Hanzlik, J.

    1977-10-01

    The project dealt with the method of using dielectric track detectors to determine the micro distribution of bone seekers, particularly radium-226. The bones studied were the mouse femur and vertebrae which were incorporated with radium-226. The preparatory work consisted of a.) preparation of dielectric foils suitable for optimal quantitative alpha autoradiography; b.) preparation of bone sections for such autoradiography; and c.) comparison of various dielectric materials. The autoradiographic method was applied to detect the radium deposition in small localities in bones and in particular, to determine the micro distribution with the aim of establishing a relationship between the incorporated activity and the dose. In evaluating such a relationship, it was concluded that it is essential to take into consideration the density distribution (using the macro method), the concentration gradient in the bands (using the semi micro method) and special track groups (using the micro method). Seven bands were observed characterized by transversal and longitudinal gradients. The transversal concentration gradients are functions of metabolism. The concentration gradients gave information about incorporative trend. Special track groupings indicate the existence of a variable course of repair process

  9. Modified theoretical minimum emittance lattice for an electron storage ring with extreme-low emittance

    Directory of Open Access Journals (Sweden)

    Yi Jiao

    2011-05-01

    Full Text Available In the continuing efforts to reduce the beam emittance of an electron storage ring composed of theoretical minimum emittance (TME lattice, down to a level of several tens of picometers, nonlinear dynamics grows to be a great challenge to the performance of the storage ring because of the strong sextupoles needed to compensate for its large global natural chomaticities coupled with its small average dispersion function. To help in dealing with the challenge of nonlinear optimization, we propose a novel variation of theoretical minimum emittance (TME lattice, named as “modified-TME” lattice, with minimal emittance about 3 times of the exact theoretical minimum, while with more compact layout, lower phase advance per cell, smaller natural chromaticities, and more relaxed optical functions than that in a TME cell, by using horizontally defocusing quadrupole closer to the dipole or simply combined-function dipole with horizontally defocusing gradient. We present approximate scaling formulas to describe the relationships of the design parameters in a modified-TME cell. The applications of modified-TME lattice in the PEP-X storage ring design are illustrated and the proposed lattice appears a good candidate for synchrotron radiation light source with extremely low emittance.

  10. An empirical study of desired versus actual compensation practices in determining intrapreneurial behaviour

    Directory of Open Access Journals (Sweden)

    Ugochukwu O. Madu

    2014-08-01

    Full Text Available Orientation: Past research recognises that human resources management practices may influence innovative behaviour, particularly as compensation systems can be used as a tool to increase intrapreneurial activity. Research purpose: The aim of this study is to determine the relationship between actual versus desired compensation practices and elevated intrapreneurial behaviour. This is in line with research that focuses on how to promote business innovation, rather than merely research whether innovation is desirable for businesses or not. Motivation for the study: Recognising that entrepreneurial actions are the bedrock of intrapreneurial behaviour and that these behaviours may be critical to the long-term vitality of a firm and economy, it is important to facilitate the empirical study of them in an underresearched, emerging market environment. Moreover, compensation such as reward preferences and variable pay schemes remain controversial in terms of their costs versus contributions, and these constructs deserve more empirical research. Research approach, design and method: The study employed a quantitative research design, using a cross-sectional and empirical approach with primary data sources. A structured webbased instrument rendered a sample of 209 respondents from a diverse set of businesses. Canonical correlational analysis was carried out to test the hypotheses. Main findings: The results reveal that a gap exists between an employee’s perception of desired compensation practices and the actual compensation practices. The results further highlight that non-outcome-based measures like pay risk, job risk and expectations of success play a role in determining whether employees decide to be intrapreneurial or not. Practical/managerial implications: Due to the potential impact rewards have on intrapreneurial behaviour, it is necessary to design relevant compensation systems as part of organisational architecture in order to foster

  11. MOKE study of Co/Ti/(Gd-Co) multilayers near the magnetic compensation state

    International Nuclear Information System (INIS)

    Svalov, A.V.; Fernandez, A.; Vas'kovskiy, V.O.; Kurlyandskaya, G.V.; Barandiaran, J.M.; Anton, R. Lopez; Tejedor, M.

    2006-01-01

    The magnetic behaviour of [Co/Ti/a-Gd 0.36 Co 0.64 /Ti] 4 /Co layered structures was studied by means of the transversal magneto-optic Kerr effect, with Ti spacers of different thicknesses. Within the Gd 0.36 Co 0.64 amorphous layer, the Gd magnetic sub-lattice dominates at all investigated temperatures. The strong exchange interaction at the interfaces causes 'macroscopic ferrimagnetic behaviour' in the whole system. The existence of a magnetic compensation state in the complete multilayer system was manifested by the change of sign in the magneto-optic hysteresis loops and the increase of coercivity. The evolution of the critical field for a spin-orientation transition leading to a non-collinear magnetic state near the 'compensation temperature' can be described within molecular field theory. The influence of the non-magnetic spacer thickness on the characteristics of the compensation state is also discussed

  12. Evaluation of compensation in breast radiotherapy: a planning study using multiple static fields

    International Nuclear Information System (INIS)

    Donovan, Ellen M.; Johnson, Ursula; Shentall, Glyn; Evans, Philip M.; Neal, Anthony J.; Yarnold, John R.

    2000-01-01

    Purpose: A method that uses electronic portal imaging to design intensity-modulated beams for compensation in breast radiotherapy was implemented using multiple static fields in a planning study. We present the results of the study to verify the algorithm, and to assess improvements to the dosimetry. Methods and Materials: Fourteen patients were imaged with computed tomography (CT) and on a treatment unit using an electronic portal imager. The portal imaging data were used to design intensity-modulated beams to give an ideal dose distribution in the breast. These beams were implemented as multiple static fields added to standard wedged tangential fields. Planning of these treatments was performed on a commercial treatment planning system (Target 2, IGE Medical Systems, Slough, U.K.) using the CT data for each patient. Dose-volume histogram (DVH) analysis of the plans with and without multileaf collimator (MLC) compensation was carried out. This work has been used as the basis for a randomized clinical trial investigating whether improvements in dosimetry are correlated with the reduction of long-term side effects from breast radiotherapy. Results: The planning analysis showed a mean increase in target volume receiving 95-105% of prescribed dose of 7.5% (range -0.8% to 15.9%) when additional MLC compensation was applied. There was no change to the minimum dose for all 14 patient data sets. The change in the volume of breast tissue receiving over 105% of prescribed dose, when applying MLC compensation, was between -1.4% and 11.9%, with positive numbers indicating an improvement. These effects showed a correlation with breast size; the larger the breast the greater the amount of improvement. Conclusions: The method for designing compensation for breast treatments using an electronic portal imager has been verified using planning on CT data for 14 patients. An improvement was seen in planning when applying MLC compensation and this effect was greater the larger the

  13. Alpha particle emitters in medicine

    International Nuclear Information System (INIS)

    Fisher, D.R.

    1989-09-01

    Radiation-induced cancer of bone, liver and lung has been a prominent harmful side-effect of medical applications of alpha emitters. In recent years, however, the potential use of antibodies labeled with alpha emitting radionuclides against cancer has seemed promising because alpha particles are highly effective in cell killing. High dose rates at high LET, effectiveness under hypoxic conditions, and minimal expectancy of repair are additional advantages of alpha emitters over antibodies labeled with beta emitting radionuclides for cancer therapy. Cyclotron-produced astatine-211 ( 211 At) and natural bismuth-212 ( 212 Bi) have been proposed and are under extensive study in the United States and Europe. Radium-223 ( 223 Ra) also has favorable properties as a potential alpha emitting label, including a short-lived daughter chain with four alpha emissions. The radiation dosimetry of internal alpha emitters is complex due to nonuniformly distributed sources, short particle tracks, and high relative specific ionization. The variations in dose at the cellular level may be extreme. Alpha-particle radiation dosimetry, therefore, must involve analysis of statistical energy deposition probabilities for cellular level targets. It must also account fully for nonuniform distributions of sources in tissues, source-target geometries, and particle-track physics. 18 refs., 4 figs

  14. Financial compensation and vocational recovery: a prospective study of secondary care neck and back patients

    DEFF Research Database (Denmark)

    Hestbæk, Lise; Rasmussen, C; Leboeuf-Yde, C

    2009-01-01

    Financial compensation has been shown to be a negative prognostic factor for pain and disability in patients with neck or low back pain. It is unclear whether this association is causal and to what extent it hampers return to work. The objective of this study was to assess the direct influence of...

  15. The effects of performance measurement and compensation on motivation: An empirical study

    NARCIS (Netherlands)

    van Herpen, M.; van Praag, C.M.; Cools, K.

    2003-01-01

    The design and implementation of a performance measurement and compensation system can strongly affect the motivation of employees. Building on economic and psychological theory this study develops a conceptual model that is used to empirically test this effect. Our survey results demonstrate a

  16. GAS MOTION STUDY OF Lyα EMITTERS AT z ∼ 2 USING FUV AND OPTICAL SPECTRAL LINES ,

    International Nuclear Information System (INIS)

    Hashimoto, Takuya; Shimasaku, Kazuhiro; Nakajima, Kimihiko; Ouchi, Masami; Ono, Yoshiaki; Rauch, Michael; Janice Lee; Okamura, Sadanori

    2013-01-01

    We present the results of Magellan/MMIRS and Keck/NIRSPEC spectroscopy for five Lyα emitters (LAEs) at z ≅ 2.2 for which high-resolution FUV spectra from Magellan/MagE are available. We detect nebular emission lines including Hα on the individual basis and low-ionization interstellar (LIS) absorption lines in a stacked FUV spectrum, and measure average offset velocities of the Lyα line, Δv Lyα , and LIS absorption lines, Δv abs , with respect to the systemic velocity defined by the nebular lines. For a sample of eight z ∼ 2-3 LAEs without active galactic nucleus from our study and the literature, we obtain Δv Lyα = 175 ± 35 km s –1 , which is significantly smaller than that of Lyman-break Galaxies (LBGs), Δv Lyα ≅ 400 km s –1 . The stacked FUV spectrum gives Δv abs = –179 ± 73 km s –1 , comparable to that of LBGs. These positive Δv Lyα and negative Δv abs suggest that LAEs also have outflows. In contrast to LBGs, however, the LAEs' Δv Lyα is as small as |Δv abs |, suggesting low neutral hydrogen column densities. Such a low column density with a small number of resonant scattering may cause the observed strong Lyα emission of LAEs. We find an anti-correlation between Lyα equivalent width (EW) and Δv Lyα in a compilation of LAE and LBG samples. Although its physical origin is not clear, this anti-correlation result appears to challenge the hypothesis that a strong outflow, by means of a reduced number of resonant scattering, produces a large EW. If LAEs at z > 6 have similarly small Δv Lyα values, constraints on the reionization history derived from the Lyα transmissivity may need to be revised.

  17. GAS MOTION STUDY OF Ly{alpha} EMITTERS AT z {approx} 2 USING FUV AND OPTICAL SPECTRAL LINES {sup ,}

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Takuya; Shimasaku, Kazuhiro; Nakajima, Kimihiko [Department of Astronomy, Graduate School of Science, The University of Tokyo, Tokyo 113-0033 (Japan); Ouchi, Masami; Ono, Yoshiaki [Institute for Cosmic Ray Research, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8582 (Japan); Rauch, Michael; Janice Lee [Observatories of the Carnegie Institution of Washington, 813 Santa Barbara Street, Pasadena, CA 91101 (United States); Okamura, Sadanori, E-mail: thashimoto@astron.s.u-tokyo.ac.jp [Department of Advanced Sciences, Faculty of Science and Engineering, Hosei University, 3-7-2 Kajino-cho, Koganei-shi, Tokyo 184-8584 (Japan)

    2013-03-01

    We present the results of Magellan/MMIRS and Keck/NIRSPEC spectroscopy for five Ly{alpha} emitters (LAEs) at z {approx_equal} 2.2 for which high-resolution FUV spectra from Magellan/MagE are available. We detect nebular emission lines including H{alpha} on the individual basis and low-ionization interstellar (LIS) absorption lines in a stacked FUV spectrum, and measure average offset velocities of the Ly{alpha} line, {Delta}v {sub Ly{alpha}}, and LIS absorption lines, {Delta}v {sub abs}, with respect to the systemic velocity defined by the nebular lines. For a sample of eight z {approx} 2-3 LAEs without active galactic nucleus from our study and the literature, we obtain {Delta}v {sub Ly{alpha}} = 175 {+-} 35 km s{sup -1}, which is significantly smaller than that of Lyman-break Galaxies (LBGs), {Delta}v {sub Ly{alpha}} {approx_equal} 400 km s{sup -1}. The stacked FUV spectrum gives {Delta}v {sub abs} = -179 {+-} 73 km s{sup -1}, comparable to that of LBGs. These positive {Delta}v {sub Ly{alpha}} and negative {Delta}v {sub abs} suggest that LAEs also have outflows. In contrast to LBGs, however, the LAEs' {Delta}v {sub Ly{alpha}} is as small as |{Delta}v {sub abs}|, suggesting low neutral hydrogen column densities. Such a low column density with a small number of resonant scattering may cause the observed strong Ly{alpha} emission of LAEs. We find an anti-correlation between Ly{alpha} equivalent width (EW) and {Delta}v {sub Ly{alpha}} in a compilation of LAE and LBG samples. Although its physical origin is not clear, this anti-correlation result appears to challenge the hypothesis that a strong outflow, by means of a reduced number of resonant scattering, produces a large EW. If LAEs at z > 6 have similarly small {Delta}v {sub Ly{alpha}} values, constraints on the reionization history derived from the Ly{alpha} transmissivity may need to be revised.

  18. NETEX Task 1: a study of the effect of ultrawideband (UWB) emitters on existing narrowband military receivers

    Science.gov (United States)

    Light, Arthur H.; Griggs, Stephen

    2003-07-01

    The goal of the DARPA NETEX program is to create a wireless networking technology for the military user that enables robust connectivity in harsh environments and support its integration into new and emerging sensor and communication systems. Phase 1 resulted in a thorough understanding of the effects of UWB system operation on existing military spectrum users based on modeling, simulation, and measurements. DARPA procured UWB emitters and broadband antennas to use as interference sources and contracted with the NAWC AD to provide candidate victim systems from the existing US inventory for testing. Testing was conducted on thirteen systems from October 2002 through March 2003. The purpose of this paper is to describe the results of these tests. It will provide a brief definition of UWB emissions as described by the US FCC and describe the generic UWB emitter used for these tests. It will then provide a brief overview of the general test plan and explain how it was adapted to the various systems tested. It will then provide a discussion of the results as they apply to the purpose of the NETEX program. Finally, the paper will look at where NETEX is going after Task 1.

  19. Low-emittance Storage Rings

    CERN Document Server

    Wolski, Andrzej

    2014-01-01

    The effects of synchrotron radiation on particle motion in storage rings are discussed. In the absence of radiation, particle motion is symplectic, and the beam emittances are conserved. The inclusion of radiation effects in a classical approximation leads to emittance damping: expressions for the damping times are derived. Then, it is shown that quantum radiation effects lead to excitation of the beam emittances. General expressions for the equilibrium longitudinal and horizontal (natural) emittances are derived. The impact of lattice design on the natural emittance is discussed, with particular attention to the special cases of FODO-, achromat- and theoretical-minimum-emittance-style lattices. Finally, the effects of betatron coupling and vertical dispersion (generated by magnet alignment and lattice tuning errors) on the vertical emittance are considered.

  20. Rare Earth Garnet Selective Emitter

    Science.gov (United States)

    Lowe, Roland A.; Chubb, Donald L.; Farmer, Serene C.; Good, Brian S.

    1994-01-01

    Thin film Ho-YAG and Er-YAG emitters with a platinum substrate exhibit high spectral emittance in the emission band (epsilon(sub lambda) approx. = 0.75, sup 4)|(sub 15/2) - (sup 4)|(sub 13/2),for Er-YAG and epsilon(sub lambda) approx. = 0.65, (sup 5)|(sub 7) - (sup 5)|(sub 8) for Ho-YAG) at 1500 K. In addition, low out-of-band spectral emittance, epsilon(sub lambda) less than 0.2, suggest these materials would be excellent candidates for high efficiency selective emitters in thermophotovoltaic (TPV) systems operating at moderate temperatures (1200-1500 K). Spectral emittance measurements of the thin films were made (1.2 less than lambda less than 3.0 microns) and compared to the theoretical emittances calculated using measured values of the spectral extinction coefficient. In this paper we present the results for a new class of rare earth ion selective emitters. These emitters are thin sections (less than 1 mm) of yttrium aluminum garnet (YAG) single crystal with a rare earth substitutional impurity. Selective emitters in the near IR are of special interest for thermophotovoltaic (TPV) energy conversion. The most promising solid selective emitters for use in a TPV system are rare earth oxides. Early spectral emittance work on rare earth oxides showed strong emission bands in the infrared (0.9 - 3 microns). However, the emittance outside the emission band was also significant and the efficiency of these emitters was low. Recent improvements in efficiency have been made with emitters fabricated from fine (5 - 10 microns) rare earth oxide fibers similar to the Welsbach mantle used in gas lanterns. However, the rare earth garnet emitters are more rugged than the mantle type emitters. A thin film selective emitter on a low emissivity substrate such as gold, platinum etc., is rugged and easily adapted to a wide variety of thermal sources. The garnet structure and its many subgroups have been successfully used as hosts for rare earth ions, introduced as substitutional

  1. Nonintercepting emittance monitor

    International Nuclear Information System (INIS)

    Miller, R.H.; Clendenin, J.E.; James, M.B.; Sheppard, J.C.

    1983-08-01

    A nonintercepting emittance monitor is a helpful device for measuring and improving particle beams in accelerators and storage rings as it allows continuous monitoring of the beam's distribution in phase space, and perhaps closed loop computer control of the distributions. Stripline position monitors are being investigated for use as nonintercepting emittance monitors for a beam focused by a FODO array in the first 100 meters of our linear accelerator. The technique described here uses the signal from the four stripline probes of a single position monitor to measure the quadrupole mode of the wall current in the beam pipe. This current is a function of the quadrupole moment of the beam, sigma 2 /sub x/ - sigma 2 /sub y/. In general, six independent measurements of the quadrupole moment are necessary to determine the beam emittance. This technique is dependent on the characteristically large variations of sigma 2 /sub x/ - sigma 2 /sub y/ in a FODO array. It will not work in a focusing system where the beam is round at each focusing element

  2. Skills and compensation strategies in adult ADHD – A qualitative study

    OpenAIRE

    Canela, Carlos; Buadze, Anna; Dube, Anish; Eich, Dominique; Liebrenz, Michael

    2017-01-01

    OBJECTIVE The primary objectives of this study were to investigate how adult patients with ADHD coped with their symptoms prior to diagnosis and treatment, what skills and compensation strategies they had developed and what their self-perceptions of these strategies were. METHODS We used a qualitative approach to analyze interviews with 32 outpatients of a specialty care unit at a university hospital. RESULTS Patients reported frequent use of diverse compensatory strategie...

  3. Helix-length compensation studies reveal the adaptability of the VS ribozyme architecture

    OpenAIRE

    Lacroix-Labonté, Julie; Girard, Nicolas; Lemieux, Sébastien; Legault, Pascale

    2011-01-01

    Compensatory mutations in RNA are generally regarded as those that maintain base pairing, and their identification forms the basis of phylogenetic predictions of RNA secondary structure. However, other types of compensatory mutations can provide higher-order structural and evolutionary information. Here, we present a helix-length compensation study for investigating structure–function relationships in RNA. The approach is demonstrated for stem-loop I and stem-loop V of the Neurospora VS riboz...

  4. Electron emitter pulsed-type cylindrical IEC

    International Nuclear Information System (INIS)

    Miley, G.H.; Gu, Y.; Stubbers, R.; Zich, R.; Anderl, R.; Hartwell, J.

    1997-01-01

    A cylindrical version of the single grid Inertial Electrostatic Confinement (IEC) device (termed the C-device) has been developed for use as a 2.5-MeV D-D fusion neutron source for neutron activation analysis. The C-device employs a hollow-tube type cathode with similar anodes backed up by ''reflector'' dishes. The resulting discharge differs from a conventional hollow cathode discharge, by creating an explicit ion beam which is ''pinched'' in the cathode region. Resulting fusion reactions generate ∼10 6 neutron/s. A pulsed version is under development for applications requiring higher fluxes. Several pulsing techniques are under study, including an electron emitter (e-emitter) assisted discharge in a thorated tungsten wire emitter located behind a slotted area in the reflector dishes. Pulsing is initiated after establishing a low power steady-state discharge by pulsing the e-emitter current using a capacitor switch type circuit. The resulting electron jet, coupled with the discharge by the biased slot array, creates a strong pulse in the pinched ion beam. The pulse length/repetition rate are controlled by the e-emitter pulse circuit. Typical parameters in present studies are ∼30micros, 10Hz and 1-amp ion current. Corresponding neutron measurements are an In-foil type activation counter for time averaged rates. Results for a wide variety of operating conditions are presented

  5. Study of on-machine error identification and compensation methods for micro machine tools

    International Nuclear Information System (INIS)

    Wang, Shih-Ming; Yu, Han-Jen; Lee, Chun-Yi; Chiu, Hung-Sheng

    2016-01-01

    Micro machining plays an important role in the manufacturing of miniature products which are made of various materials with complex 3D shapes and tight machining tolerance. To further improve the accuracy of a micro machining process without increasing the manufacturing cost of a micro machine tool, an effective machining error measurement method and a software-based compensation method are essential. To avoid introducing additional errors caused by the re-installment of the workpiece, the measurement and compensation method should be on-machine conducted. In addition, because the contour of a miniature workpiece machined with a micro machining process is very tiny, the measurement method should be non-contact. By integrating the image re-constructive method, camera pixel correction, coordinate transformation, the error identification algorithm, and trajectory auto-correction method, a vision-based error measurement and compensation method that can on-machine inspect the micro machining errors and automatically generate an error-corrected numerical control (NC) program for error compensation was developed in this study. With the use of the Canny edge detection algorithm and camera pixel calibration, the edges of the contour of a machined workpiece were identified and used to re-construct the actual contour of the work piece. The actual contour was then mapped to the theoretical contour to identify the actual cutting points and compute the machining errors. With the use of a moving matching window and calculation of the similarity between the actual and theoretical contour, the errors between the actual cutting points and theoretical cutting points were calculated and used to correct the NC program. With the use of the error-corrected NC program, the accuracy of a micro machining process can be effectively improved. To prove the feasibility and effectiveness of the proposed methods, micro-milling experiments on a micro machine tool were conducted, and the results

  6. Monolithic multinozzle emitters for nanoelectrospray mass spectrometry

    Science.gov (United States)

    Wang, Daojing [Daly City, CA; Yang, Peidong [Kensington, CA; Kim, Woong [Seoul, KR; Fan, Rong [Pasadena, CA

    2011-09-20

    Novel and significantly simplified procedures for fabrication of fully integrated nanoelectrospray emitters have been described. For nanofabricated monolithic multinozzle emitters (NM.sup.2 emitters), a bottom up approach using silicon nanowires on a silicon sliver is used. For microfabricated monolithic multinozzle emitters (M.sup.3 emitters), a top down approach using MEMS techniques on silicon wafers is used. The emitters have performance comparable to that of commercially-available silica capillary emitters for nanoelectrospray mass spectrometry.

  7. Study on a Mechanical Semi-Active Heave Compensation System of Drill String for Use on Floating Drilling Platform

    Science.gov (United States)

    Liu, Qingyou; Tang, Yang; Huang, Chongjun; Xie, Chong

    2015-01-01

    There are some disadvantages for existing heave compensation systems of drill string used for the Floating Drilling Platform (FDP), including high energy consumption, large and complex structure, and expensive manufacturing and maintenance costs. In view of the above, we present a streamlined mechanical semi-active heave compensation system (MSAHC) in this study. This system consists of active compensation part with the pinion and rack and passive compensation part. In order to evaluate system performance of the MSAHC, we establish its simulation model with AMEsim software. In the process of simulation, displacement of rotary hook and energy consumption is regarded as performance parameters of the system. And the change rule of two performance parameters are analyzed by changing these design parameters including gear radius of the pinion and rack, scale coefficient of PID, rotary hook load, heave height and heave period of the FDP, and accumulator volume. Then, based on the simulation results of the MSAHC system performance, we have selected out a best set of design parameters from them. Moreover, the feasibility of the design scheme of the MSAHC is effectively verified by comparison with the existing three heave compensation system. The result shows that the energy consumption of the MSAHC is lower than the active heave compensation system (AHC) and the semi-active heave compensation system (SAHC) when achieving a same compensation effect as well as the accumulator volume of MSAHC is half of the passive heave compensation system (PHC). Therefore, the new designed MSAHC not only ensure compensation effect but also lower energy consumption, and its structure is simplified by adopting the simple mechanical structure to decrease manufacturing cost, maintenance cost and floor space. PMID:26186620

  8. TH-EF-BRB-08: Robotic Motion Compensation for Radiation Therapy: A 6DOF Phantom Study

    Energy Technology Data Exchange (ETDEWEB)

    Belcher, AH; Liu, X; Wiersma, R [The University of Chicago, Chicago, IL (United States)

    2016-06-15

    Purpose: The high accuracy of frame-based stereotactic radiosurgery (SRS), which uses a rigid frame fixed to the patient’s skull, is offset by potential drawbacks of poor patient compliance and clinical workflow restrictions. Recent research into frameless SRS has so far resulted in reduced accuracy. In this study, we investigate the use of a novel 6 degree-of-freedom (6DOF) robotic head motion cancellation system that continuously detects and compensates for patient head motions during a SRS delivery. This approach has the potential to reduce invasiveness while still achieving accuracies better or equal to traditional frame-based SRS. Methods: A 6DOF parallel kinematics robotics stage was constructed, and controlled using an inverse kinematics-based motion compensation algorithm. A 6DOF stereoscopic infrared (IR) marker tracking system was used to monitor real-time motions at sub-millimeter and sub-degree levels. A novel 6DOF calibration technique was first applied to properly orient the camera coordinate frame to match that of the LINAC and robotic control frames. Simulated head motions were measured by the system, and the robotic stage responded to these 6DOF motions automatically, returning the reflective marker coordinate frame to its original position. Results: After the motions were introduced to the system in the phantom-based study, the robotic stage automatically and rapidly returned the phantom to LINAC isocenter. When errors exceeded the compensation lower threshold of 0.25 mm or 0.25 degrees, the system registered the 6DOF error and generated a cancellation trajectory. The system responded in less than 0.5 seconds and returned all axes to less than 0.1 mm and 0.1 degree after the 6DOF compensation was performed. Conclusion: The 6DOF real-time motion cancellation system was found to be effective at compensating for translational and rotational motions to current SRS requirements. This system can improve frameless SRS by automatically returning

  9. TH-EF-BRB-08: Robotic Motion Compensation for Radiation Therapy: A 6DOF Phantom Study

    International Nuclear Information System (INIS)

    Belcher, AH; Liu, X; Wiersma, R

    2016-01-01

    Purpose: The high accuracy of frame-based stereotactic radiosurgery (SRS), which uses a rigid frame fixed to the patient’s skull, is offset by potential drawbacks of poor patient compliance and clinical workflow restrictions. Recent research into frameless SRS has so far resulted in reduced accuracy. In this study, we investigate the use of a novel 6 degree-of-freedom (6DOF) robotic head motion cancellation system that continuously detects and compensates for patient head motions during a SRS delivery. This approach has the potential to reduce invasiveness while still achieving accuracies better or equal to traditional frame-based SRS. Methods: A 6DOF parallel kinematics robotics stage was constructed, and controlled using an inverse kinematics-based motion compensation algorithm. A 6DOF stereoscopic infrared (IR) marker tracking system was used to monitor real-time motions at sub-millimeter and sub-degree levels. A novel 6DOF calibration technique was first applied to properly orient the camera coordinate frame to match that of the LINAC and robotic control frames. Simulated head motions were measured by the system, and the robotic stage responded to these 6DOF motions automatically, returning the reflective marker coordinate frame to its original position. Results: After the motions were introduced to the system in the phantom-based study, the robotic stage automatically and rapidly returned the phantom to LINAC isocenter. When errors exceeded the compensation lower threshold of 0.25 mm or 0.25 degrees, the system registered the 6DOF error and generated a cancellation trajectory. The system responded in less than 0.5 seconds and returned all axes to less than 0.1 mm and 0.1 degree after the 6DOF compensation was performed. Conclusion: The 6DOF real-time motion cancellation system was found to be effective at compensating for translational and rotational motions to current SRS requirements. This system can improve frameless SRS by automatically returning

  10. Low emittance electron storage rings

    Science.gov (United States)

    Levichev, E. B.

    2018-01-01

    Low-emittance electron (positron) beams are essential for synchrotron light sources, linear collider damping rings, and circular Crab Waist colliders. In this review, the principles and methods of emittance minimization are discussed, prospects for developing relativistic electron storage rings with small beam phase volume are assessed, and problems related to emittance minimization are examined together with their possible solutions. The special features and engineering implementation aspects of various facilities are briefly reviewed.

  11. Optimization of coronary optical coherence tomography imaging using the attenuation-compensated technique: a validation study.

    NARCIS (Netherlands)

    Teo, Jing Chun; Foin, Nicolas; Otsuka, Fumiyuki; Bulluck, Heerajnarain; Fam, Jiang Ming; Wong, Philip; Low, Fatt Hoe; Leo, Hwa Liang; Mari, Jean-Martial; Joner, Michael; Girard, Michael J A; Virmani, Renu; Bezerra, HG.; Costa, MA.; Guagliumi, G.; Rollins, AM.; Simon, D.; Gutiérrez-Chico, JL.; Alegría-Barrero, E.; Teijeiro-Mestre, R.; Chan, PH.; Tsujioka, H.; de Silva, R.; Otsuka, F.; Joner, M.; Prati, F.; Virmani, R.; Narula, J.; Members, WC.; Levine, GN.; Bates, ER.; Blankenship, JC.; Bailey, SR.; Bittl, JA.; Prati, F.; Guagliumi, G.; Mintz, G.S.; Costa, Marco; Regar, E.; Akasaka, T.; Roleder, T.; Jąkała, J.; Kałuża, GL.; Partyka, Ł.; Proniewska, K.; Pociask, E.; Girard, MJA.; Strouthidis, NG.; Ethier, CR.; Mari, JM.; Mari, JM.; Strouthidis, NG.; Park, SC.; Girard, MJA.; van der Lee, R.; Foin, N.; Otsuka, F.; Wong, P.K.; Mari, J-M.; Joner, M.; Nakano, M.; Vorpahl, M.; Otsuka, F.; Taniwaki, M.; Yazdani, SK.; Finn, AV.; Nakano, M.; Yahagi, K.; Yamamoto, H.; Taniwaki, M.; Otsuka, F.; Ladich, ER.; Girard, MJ.; Ang, M.; Chung, CW.; Farook, M.; Strouthidis, N.; Mehta, JS.; Foin, N.; Mari, JM.; Nijjer, S.; Sen, S.; Petraco, R.; Ghione, M.; Liu, X.; Kang, JU.; Virmani, R.; Kolodgie, F.D.; Burke, AP.; Farb, A.; Schwartz, S.M.; Yahagi, K.; Kolodgie, F.D.; Otsuka, F.; Finn, AV.; Davis, HR.; Joner, M.; Kume, T.; Akasaka, T.; Kawamoto, T.; Watanabe, N.; Toyota, E.; Neishi, Y.; Rieber, J.; Meissner, O.; Babaryka, G.; Reim, S.; Oswald, M.E.; Koenig, A.S.; Tearney, G. J.; Regar, E.; Akasaka, T.; Adriaenssens, T.; Barlis, P.; Bezerra, HG.; Yabushita, H.; Bouma, BE.; Houser, S. L.; Aretz, HT.; Jang, I-K.; Schlendorf, KH.; Guo, J.; Sun, L.; Chen, Y.D.; Tian, F.; Liu, HB.; Chen, L.; Kawasaki, M.; Bouma, BE.; Bressner, J. E.; Houser, S. L.; Nadkarni, S. K.; MacNeill, BD.; Jansen, CHP.; Onthank, DC.; Cuello, F.; Botnar, RM.; Wiethoff, AJ.; Warley, A.; von Birgelen, C.; Hartmann, A. M.; Kubo, T.; Akasaka, T.; Shite, J.; Suzuki, T.; Uemura, S.; Yu, B.; Habara, M.; Nasu, K.; Terashima, M.; Kaneda, H.; Yokota, D.; Ko, E.; Virmani, R.; Burke, AP.; Kolodgie, F.D.; Farb, A.; Takarada, S.; Imanishi, T.; Kubo, T.; Tanimoto, T.; Kitabata, H.; Nakamura, N.; Hattori, K.; Ozaki, Y.; Ismail, TF.; Okumura, M.; Naruse, H.; Kan, S.; Nishio, R.; Shinke, T.; Otake, H.; Nakagawa, M.; Nagoshi, R.; Inoue, T.; Sinclair, H.D.; Bourantas, C.; Bagnall, A.; Mintz, G.S.; Kunadian, V.; Tearney, G. J.; Yabushita, H.; Houser, S. L.; Aretz, HT.; Jang, I-K.; Schlendorf, KH.; van Soest, G.; Goderie, T.; Regar, E.; Koljenović, S.; Leenders, GL. van; Gonzalo, N.; Xu, C.; Schmitt, JM.; Carlier, SG.; Virmani, R.; van der Meer, FJ; Faber, D.J.; Sassoon, DMB.; Aalders, M.C.; Pasterkamp, G.; Leeuwen, TG. van; Schmitt, JM.; Knuttel, A.; Yadlowsky, M.; Eckhaus, MA.; Karamata, B.; Laubscher, M.; Leutenegger, M.; Bourquin, S.; Lasser, T.; Lambelet, P.; Vermeer, K.A.; Mo, J.; Weda, J.J.A.; Lemij, H.G.; Boer, JF. de

    2016-01-01

    PURPOSE To optimize conventional coronary optical coherence tomography (OCT) images using the attenuation-compensated technique to improve identification of plaques and the external elastic lamina (EEL) contour. METHOD The attenuation-compensated technique was optimized via manipulating contrast

  12. Study of the radioactive impurities gamma emitters present in the radiopharmaceutical solutions produced at IPEN/CNEN-SP

    International Nuclear Information System (INIS)

    Almeida, Jamille da Silveira

    2017-01-01

    This work aims to investigate the concentration of radioactive impurities gamma emitters in the radiopharmaceutical solutions produced at Nuclear and Energy Research Institute -IPEN in Sao Paulo, So that this radiopharmaceutical may be used properly, its quality should be evaluated in accordance with the procedures established by quality control agencies, such as General Requirements for the Competence of Testing and Calibration Laboratories' ISO/IEC 17025:2005 and the 'Good Laboratory Practice (GLP), controlled by ANVISA (National Agency Health Surveillance), in Brazil, requiring a confirmation of the values of impurities related at the certificates supplied by the manufacturers. To determine the activity, a high resolution gamma spectrometer were used in two source-detector distances. One was 18 cm and the other 1.7 cm. For the 18 cm distance, the high pure germanium spectrometer was calibrated in the energy range between 81 keV and 1408 keV by measuring sealed ampoules of "6"0Co, "1"3"3Ba, "1"3"7Cs and "1"5"2Eu, standardized at the Nuclear Metrology Laboratory (NML) of IPEN. For lower activity of the impurities, the distance source-detector of 1.7 cm was assumed. However, as at this distance, the sum coincidence effect is very high, making the measurement of the standard calibration ampoules difficult, the spectrometer efficiency curve was obtained by a Monte Carlo simulation code, developed at IPEN. In this code, all details of the detection system are modeled and the response curves for x-rays and gamma rays are calculated by the MCNPX radiation transport code. The gamma spectra were analyzed by Alpino code, which applies the method of numeric peak integration of the area under the photopeaks. For gamma emitter impurities, not visually detected, the decision threshold and the detection limits were calculated from the background count rate, under the peak area. The radiopharmaceutical solutions analyzed were "6"7Ga, "9"9Mo, "9"9"mTc, "1"1"1In, "1"3"1I, "1"5"3Sm

  13. Space Charge Compensation in the Linac4 Low Energy Beam Transport Line with Negative Hydrogen Ions

    CERN Document Server

    Valerio-Lizarraga, C; Leon-Monzon, I; Lettry, J; Midttun, O; Scrivens, R

    2014-01-01

    The space charge effect of low energy, unbunched ion beams can be compensated by the trapping of ions or electrons into the beam potential. This has been studied for the 45 keV negative hydrogen ion beam in the CERN Linac4 Low Energy Beam Tranport (LEBT) using the package IBSimu1, which allows the space charge calculation of the particle trajectories. The results of the beam simulations will be compared to emittance measurements of an H- beam at the CERN Linac4 3 MeV test stand, where the injection of hydrogen gas directly into the beam transport region has been used to modify the space charge compensation degree.

  14. Study designs for identifying risk compensation behavior among users of biomedical HIV prevention technologies: balancing methodological rigor and research ethics.

    Science.gov (United States)

    Underhill, Kristen

    2013-10-01

    The growing evidence base for biomedical HIV prevention interventions - such as oral pre-exposure prophylaxis, microbicides, male circumcision, treatment as prevention, and eventually prevention vaccines - has given rise to concerns about the ways in which users of these biomedical products may adjust their HIV risk behaviors based on the perception that they are prevented from infection. Known as risk compensation, this behavioral adjustment draws on the theory of "risk homeostasis," which has previously been applied to phenomena as diverse as Lyme disease vaccination, insurance mandates, and automobile safety. Little rigorous evidence exists to answer risk compensation concerns in the biomedical HIV prevention literature, in part because the field has not systematically evaluated the study designs available for testing these behaviors. The goals of this Commentary are to explain the origins of risk compensation behavior in risk homeostasis theory, to reframe risk compensation as a testable response to the perception of reduced risk, and to assess the methodological rigor and ethical justification of study designs aiming to isolate risk compensation responses. Although the most rigorous methodological designs for assessing risk compensation behavior may be unavailable due to ethical flaws, several strategies can help investigators identify potential risk compensation behavior during Phase II, Phase III, and Phase IV testing of new technologies. Where concerns arise regarding risk compensation behavior, empirical evidence about the incidence, types, and extent of these behavioral changes can illuminate opportunities to better support the users of new HIV prevention strategies. This Commentary concludes by suggesting a new way to conceptualize risk compensation behavior in the HIV prevention context. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Commissioning of the SPARC Movable Emittance Meter and Its First Operation at PITZ

    CERN Document Server

    Catani, L; Cianchi, A

    2005-01-01

    For the SPARC Project a novel diagnostic device, called "Emittance-meter", has been conceived and constructed to perform a detailed study of the emittance compensation process in the SPARC photo-injector and to optimize the RF-gun and the accelerator working point. It consists of a movable emittance measurement system, based on the 1D pepper-pot method, installed between two long bellows with the possibility to scan a region 1.5 m long downstream the RF-gun. The construction of the device was completed in the first part of this year and a series of laboratory tests, to evaluate its performances, were carried out in Spring 2005. At the beginning of the summer the complete system was moved to DESY at Zeuthen to be installed on the Photo Injector Test Facility PITZ. After the commissioning it will used for measurements of the PITZ electron beam in the framework of a collaboration between the SPARC and PITZ Projects aiming on studies and operations with photo injectors.

  16. A comparative study of Kalman filter and Linear Matrix Inequality based H infinity filter for SPND delay compensation

    International Nuclear Information System (INIS)

    Tamboli, P.K.; Duttagupta, Siddhartha P.; Roy, Kallol

    2016-01-01

    Highlights: • Derivation for delay compensation algorithm using recursive Kalman filter. • Derivation for delay compensation algorithm using Linear Matrix Inequality based H infinity filter. • Process modeling suitable for delay compensation. • Dynamic tuning of the delay compensation algorithm for both Kalman and H infinity filter. • Simulations and trade-off curve for Kalman and H infinity filter. - Abstract: This paper deals with delay compensation of vanadium Self Powered Neutron Detectors (SPNDs) using Linear Matrix Inequality (LMI) based H-infinity filtering method and compares the results with Kalman filtering method. The entire study is established upon the framework of neutron flux estimation in large core Pressurized Heavy Water Reactor (PHWR) in which delayed SPNDs such as vanadium SPNDs are used as in-core flux monitoring detectors. The use of vanadium SPNDs are limited to 3-D flux mapping despite of providing better Signal to Noise Ratio as compared to other prompt SPNDs, due to their small prompt component in the signal. The use of an appropriate delay compensation technique has been always considered to be an effective strategy to build a prompt and accurate estimate of the neutron flux. We also indicate the noise-response trade-off curve for both the techniques. Since all the delay compensation algorithms always suffer from noise amplification, we propose an efficient adaptive parameter tuning technique for improving performance of the filtering algorithm against noise in the measurement.

  17. The possible role of solitons in energy transfer in DNA: the relevance of studies with Auger emitters

    International Nuclear Information System (INIS)

    Baverstock, K.F.; Cundall, R.B.

    1988-01-01

    The interpretation of some experiments in which ionising energy is directly absorbed by DNA involve postulates that large scale energy migration takes place in DNA over long distances (kilobase pairs). A possible mechanism for such processes is provided by solitary vibrational waves called solitons. (Solitons arise when a pseudo-one dimensional system with non-linear characteristics suffers a large local transitory displacement from equilibrium). Various synthetic polymers, such as polyacetylene are known, to sustain solitons and various physical properties of biopolymers such as DNA can be described in terms of 'open states' associated with inplane rotation of a group of the hydrogen bonded bases which has solitonic properties. The absorption of ionising energy by DNA systems can provide the transient displacement from equilibrium necessary to set-up wave conditions appropriate for soliton production. Auger emitters would be particularly well suited for inducing solitons and offer the possibility for causing ionising energy to be 'injected' into the DNA molecule at a specific point in the molecular sequence. Experiments to test the hypothesis that this event causes long range energy transfer are discussed. (author)

  18. Study on the balance mechanism of interests in marine ecological compensation

    Science.gov (United States)

    Qian, Cao; Hongjun, Cao; Hongcai, Yan

    2017-11-01

    From the point of view of game theory and through establishing the game model of the subject and object of marine ecological compensation, this paper makes a research on the balance mechanism the interests of marine ecological compensation. The results show that the optimal amount of capital investment of environmental protection enterprises for ecological compensation depends not only on energy conservation and emission reduction of itself as well as competition enterprises, but also on the policy support for ecological compensation. At the same time, it is limited by the public’s understanding and acceptance for ecological compensation.

  19. Emittance growth due to dipole ripple and sextupole

    International Nuclear Information System (INIS)

    Shih, H.J.; Ellison, J.A.; Syphers, M.J.; Newberger, B.S.

    1993-05-01

    Ripple in the power supplies for storage ring magnets can have adverse effects on the circulating beams: orbit distortion and emittance growth from dipole ripple, tune modulation and dynamic aperture reduction from quadrupole ripple, etc. In this paper, we study the effects of ripple in the horizontal bending field of the SSC in the presence of nonlinearity, in particular, the growth in beam emittance

  20. A cross-language study of compensation in response to real-time formant perturbation

    DEFF Research Database (Denmark)

    Mitsuya, Takashi; MacDonald, Ewen; Purcell, David W.

    2011-01-01

    error operates at a purely acoustic level. This hypothesis was tested by comparing the response of three language groups to real-time formant perturbations, (1) native English speakers producing an English vowel /e/, (2) native Japanese speakers producing a Japanese vowel (=e...Past studies have shown that when formants are perturbed in real time, speakers spontaneously compensate for the perturbation by changing their formant frequencies in the opposite direction to the perturbation. Further, the pattern of these results suggests that the processing of auditory feedback...... for formant perturbation operates at a purely acoustic level was rejected. Rather, some level of phonological processing influences the feedback processing behavior....

  1. A quality-driven physician compensation model: four-year follow-up study.

    Science.gov (United States)

    Chung, Richard S; Chernicoff, Helen O; Nakao, Kimberly A; Nickel, Robert C; Legorreta, Antonio P

    2003-01-01

    This case report describes a qualitative and preliminary quantitative assessment of a quality-based physician compensation program. The Hawaii Medical Service Association's Physician Quality and Service Recognition program offers an innovative and effective approach for improving delivery of high-quality and cost-effective care to patients enrolled in preferred provider organizations. Support for the program is demonstrated through increasing numbers of voluntarily participating physicians. Preliminary assessment of population outcomes reveals sustained improvements in many clinical areas and mixed findings in others. This study contributes to the body of knowledge available to payers and policy makers considering alternative payment methods to reward improved performance.

  2. Creative compensation

    International Nuclear Information System (INIS)

    Coll, D.

    1994-01-01

    A discussion is presented of executive compensation in Canada's petroleum industry. Mandatory disclosure of executive compensation and benefits is regulated by the Ontario Securities Commission. Examination of the compensation packages of 80 oilpatch CEOs shows a clear difference in philosophy between large and small companies. Larger companies pay larger salaries, offer pension plans, and reward long-term loyalty. Within smaller companies, compensation tends to be linked with stock performance. Trends in compensation are to lower base salaries with more variables such as bonuses, cash incentives and gain-sharing programs. Increasing shareholder scrutiny is prompting more stringent guidelines on stock option plans. Some companies place performance conditions on stock vesting. Another option is to grant premium priced options to executives, to increase the gains required for the executive to post a profit. Other comapanies are granting stock options to their field personnel, or are granting stock to all employees. Directors are playing an increasing role in executive compensation. 4 tabs

  3. Emittance growth in rf linacs

    International Nuclear Information System (INIS)

    Jameson, R.A.

    1979-01-01

    As the space-charge limit is approached, the current that can be accelerated in an rf linac and the output emittance that can be expected are discussed. The role of the envelope equations to estimate limits is outlined. The results of numerical experiments to explore general properties of emittance growth are given

  4. Treatment of carcinoma in situ of the urinary bladder with an alpha-emitter immunoconjugate targeting the epidermal growth factor receptor: a pilot study.

    Science.gov (United States)

    Autenrieth, Michael E; Seidl, Christof; Bruchertseifer, Frank; Horn, Thomas; Kurtz, Florian; Feuerecker, Benedikt; D'Alessandria, Calogero; Pfob, Christian; Nekolla, Stephan; Apostolidis, Christos; Mirzadeh, Saed; Gschwend, Jürgen E; Schwaiger, Markus; Scheidhauer, Klemens; Morgenstern, Alfred

    2018-07-01

    Patients with carcinoma in situ (CIS) of the bladder refractory to bacillus Calmette-Guérin (BCG) treatment are usually treated with cystectomy. Therefore, new treatment options with preservation of the urinary bladder are needed. The objective of the study was to investigate the feasibility, safety and efficacy of a novel targeted alpha-emitter immunotherapy for CIS after BCG treatment failure. A pilot study was conducted in 12 patients (age range 64-86 years, ten men, two women) with biopsy-proven CIS of the bladder refractory to BCG treatment. The patients were treated intravesically with a single instillation (one patient was treated twice) of the alpha-emitter 213 Bi coupled to an anti-EGFR antibody (366-821 MBq). The primary aims of the study were to determine the feasibility of treatment with the 213 Bi-immunoconjugate and evaluation of adverse effects. Therapeutic efficacy was monitored by histological mapping of the urinary bladder 8 weeks after treatment and at different time points thereafter. The study proved that intravesical instillation of the 213 Bi-immunoconjugate targeting EGFR is feasible. No adverse effects were observed and all blood and urine parameters determined remained in their normal ranges. Therapeutic efficacy was considered satisfactory, in that three of the 12 patients showed no signs of CIS 44, 30 and 3 months after treatment. Intravesical instillation of 213 Bi-anti-EGFR monoclonal antibody was well tolerated and showed therapeutic efficacy. Repeated instillation and/or instillation of higher activities of the 213 Bi-immunoconjugate might lead to better therapeutic outcomes. A phase I clinical trial is planned.

  5. Are people who claim compensation "cured by a verdict"? A longitudinal study of health outcomes after whiplash.

    Science.gov (United States)

    Spearing, Natalie M; Gyrd-Hansen, Dorte; Pobereskin, Louis H; Rowell, David S; Connelly, Luke B

    2012-09-01

    This study examines whether the lure of injury compensation prompts whiplash claimants to overstate their symptoms. Claim settlement is the intervention of interest, as it represents the point at which there is no further incentive to exaggerate symptoms, and neck pain at 24 months is the outcome of interest. Longitudinal data on neck pain scores and timing of claim settlement were regressed, controlling for the effect of time on recovery, to compare outcomes in claimants who had and had not settled their compensation claims. The results show clearly that removing the financial incentive to over-report symptoms has no effect on self-reported neck pain in a fault-based compensation scheme, and this finding concurs with other studies on this topic. Policy decisions to limit compensation in the belief that claimants systematically misrepresent their health status are not supported empirically Claimants do not appear to be "cured by a verdict".

  6. Assessment of beta-emitter radionuclides in biological samples using liquid scintillation counting. Application to the study of internal doses in molecular and cellular biology techniques

    International Nuclear Information System (INIS)

    Sierra, I.; Delgado, A.; Navarro, T.; Macias, M. T.

    2007-01-01

    The radioisotopic techniques used in Molecular and Cellular Biology involve external and internal irradiation risk. It is necessary to control the possible internal contamination associated to the development of these techniques. The internal contamination risk can be due to physical and chemical properties of the labelled compounds, aerosols generated during the performance technique. The aim of this work was to estimate the possible intake of specific beta emitters during the technique development and to propose the required criterions to perform Individual Monitoring. The most representative radioisotopic techniques were selected attending their potential risk of internal contamination. Techniques were analysed applying IAEA methodology according to the used activity in each technique. It was necessary to identify the worker groups that would require individual monitoring on the base of their specific risk. Different measurement procedures were applied to study the possible intake in group risk and more than 160 persons were measured by in vitro bioassay. (Author) 96 refs

  7. Emittance growth rates for displaced beams

    International Nuclear Information System (INIS)

    Anderson, O.A.

    1993-05-01

    Emittance growth rates have been previously analyzed for nonuniform beams in linear channels and for initially uniform mismatched beams in nonlinear channels. These studies were for centered beams. Additional emittance growth can arise in cases where the beam is initially displaced. The purpose of this study is to obtain growth rates for displaced beams. This work differs from studies involving random displacement of electrodes. Our analysis assumes instead that the focusing system is perfectly aligned but that the beam is initially displaced with respect to the equilibrium axis. If the focusing force is slightly nonlinear, we find a gradual transfer of the potential energy of beam displacement into kinetic energy associated with emittance growth. We present explicit results for the emittance growth distance as a function of the nonlinearity of the channel. These results will have practical importance for designers of accelerators and transport systems when setting realistic tolerances for initial beam alignment. These tolerances will depend on the nonlinearity and the length of the system

  8. Argumentative Strategies in the Action of Compensation for Moral Damages: a Study of an Initial Petition

    Directory of Open Access Journals (Sweden)

    Ariana de Carvalho

    2016-12-01

    Full Text Available Guided by the semiolinguistics theory, this work intended to investigate initial petition involving a claim for compensation for moral damages in consumer relations, verifying how the dimensions of the features of logos and pathos were used by lawyers to persuade the judge that the claim for compensation was valid. This study also aimed to investigate which socio-discursive imaginaries were expressed in these speeches. We came to the conclusion that the notion of communication contract is very striking and guiding in these speeches. It was also found a predominance of the dimension of logos and a regularity in the use of techniques from this dimension. We also found that the patêmica order arguments also had a great importance in the argumentation, as being the moral damage connected directly to the emotional shock of the applicant for the violation of his rights, the argument based only on the logos would be somewhat consistent. It was clear that the lawyer’s voice comes from the collectivity with which he shares values and principles.

  9. Coercion, dissatisfaction, and social stigma: an ethnographic study of compensated living kidney donation in Iran.

    Science.gov (United States)

    Fry-Revere, Sigrid; Chen, Deborah; Bastani, Bahar; Golestani, Simin; Agarwal, Rachana; Kugathasan, Howsikan; Le, Melissa

    2018-02-26

    This article updates the qualitative research on Iran reported in the 2012 article by Tong et al. "The experiences of commercial kidney donors: thematic synthesis of qualitative research" (Tong et al. in Transpl Int 25:1138-1149, 2012). The basic approach used in the Tong et al. article is applied to a more recent and more comprehensive study of Iranian living organ donors, providing a clearer picture of what compensated organ donation is like in Iran since the national government began regulating compensated donation. Iran is the only country in the world where kidney selling is legal, regulated, and subsidized by the national government. This article focuses on three themes: (1) coercion and other pressures to donate, (2) donor satisfaction with their donation experience, and (3) whether donors fear social stigma. We found no evidence of coercion, but 68% of the paid living organ donors interviewed felt pressure to donate due to extreme poverty or other family pressures. Even though 27% of the living kidney donors interviewed said they were satisfied with their donation experience, 74% had complaints about the donation process or its results, including some of the donors who said they were satisfied. In addition, 84% of donors indicated they feared experiencing social stigma because of their kidney donation.

  10. Measurements of Transverse Emittance for RF Photocathode Gun at the PAL

    CERN Document Server

    Park Jang Ho; Park, Sung-Ju; Soo Ko In; Wang, Xijie; Woon Parc, Yong; Xiang, Dao

    2005-01-01

    A BNL GUN-IV type RF photo-cathode gun is under fabrication for use in the FIR (Far Infra-Red) facility being built at the Pohang Accelerator Laboratory (PAL). Performance test of the gun will include the measurement of transverse emittance profile along the longitudinal direction. Successful measurement of the emittance profile will provide powerful tool for the commissioning of the 4GLS (4th generation light source) injectors based on the emittance compensation principle. We are going to achieve this withthe use of pepper-pot based emittance meters that can be moved along the longitudinal direction. In this article, we present design considerations on the emittance meter with the resolution of 1 mm mrad.

  11. Losses compensation; Compensation des pertes

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    One mission of RTE (Electric Power Transportation), is to watch over the losses compensation resulting from the power transport on the electric power network. Since january 2001, RTE makes good the electric losses by the purchase of energy. To choose the marketers, a consultation has been realized by RTE. This document presents the rules concerning these losses compensation. (A.L.B.)

  12. Eating Patterns in Patients with Compensated Cirrhosis: A Case-Control Study

    Directory of Open Access Journals (Sweden)

    Camille Buscail

    2018-01-01

    Full Text Available Background: There is growing evidence suggesting that maintaining an adequate nutritional status for patients with liver cirrhosis (LC is relevant to prevent complications. The present study aimed to describe dietary behaviours of patients with compensated and non-complicated LC and comparing them with those of subjects from the general population. Methods: In this case-control study, patients were volunteers enrolled in the ALICIR (ALImentation et CIRrhose study, an observational survey nested in two French prospective cohorts of patients with biopsy-proven compensated cirrhosis related either to excessive alcohol consumption (CIRRAL or to hepatitis B or C virus infection (CirVir. Controls were selected from the NutriNet-Santé cohort. Dietary data were collected through a semi quantitative food frequency questionnaire. Dietary and nutritional data were compared using multi-adjusted paired Student’s tests. Results: Between June 2014 and February 2016, 174 patients of CirVir (N = 97 or CIRRAL (N = 77 were matched with 348 controls from the NutriNet-Santé cohort, according to gender, age, BMI and educational level. Compared to controls, patients (mean ± SD consumed more sodas (236.0 ± 29.8 mL vs. 83.0 ± 33.0 mL and water (1787.6 ± 80.6 mL vs. 933.6 ± 85.3 mL, and lower amounts of salty snacks (4.2 ± 1.42 g vs. 9.0 ± 1.6 g and alcoholic beverages (71.8 ± 23.4 g vs. 151.2 ± 25.9 g, with all p values < 0.0001. Dietary behaviours differed according to LC aetiology. Conclusions: Dietary behaviour of patients significantly differed from subjects from the general population.

  13. A study on multi-point gravity compensation of mirror bending system

    International Nuclear Information System (INIS)

    Sun Fuquan; Fu Yuan; Zhu Wanqian; Xue Song

    2011-01-01

    The sag of mirror due to gravity induces unacceptable slope errors in beamline mirror-bending system of a synchrotron radiation facility, and approaches must be found to eliminate the unwanted gravity effect. According to the beam bending theory, the multi-point gravity compensation method is applicable. Taking an example of the bent collimating mirror for the XAFS beam-line (BL14W) at Shanghai Synchrotron Radiation Facility (SSRF), the best position and value of the equilibrant were calculated through minimizing the gravity effect. With two, three and four points gravity compensation, slope errors were 0.179, 0.067 and 0.032 μrad,respectively, i.e.the multi-point gravity compensation is better than the two-point gravity compensation, which is used for the Phase I beamlines of SSRF. The four-point gravity compensation method reduces more slope error and stress due to four support points. (authors)

  14. The study of thickness and density compensation of neutron-measuring moisture system on conveyor belt

    International Nuclear Information System (INIS)

    Jia Wenbao; Su Tongling; Zhang Xiaomin; Xu Zhongfeng

    1999-01-01

    The neutron-measuring transmission moisture system on the conveyer belt is systematically studied. A method of density and thickness compensation has been used to carryout the on-line measurements of the moisture of the unshaped, discontinuous and irregular moving matter. At the same time, the thickness weighed average method is employed to modify the prompt moisture at a fixed time, and to improve the accuracy of measuring the moisture. The experimental data show that the measurement errors are within ±2.5% when the thickness is between 2 cm and 16 cm and the water percentage is between 6% and 16%. The errors can reach 0.2% if thickness weighed average for moving matter lasts for a long time

  15. Studies On The Materiality And Aggregation, Compensation And Offsetting In Financial Statements

    Directory of Open Access Journals (Sweden)

    Liana GADAU

    2016-04-01

    Full Text Available The accounting principles should be considered an essential element in the preparation and presentation of financial statements, with our analysis focusing especially on the relative principles: Materiality and aggregation, compensation and offsetting. We consider necessary to improve the analyzed concepts by bringing additional information, as clear and comprehensive as possible, information used as reference in the preparation of financial statements.  Moreover, is crucial to apply an unitary thinking of the accounting referential which is linked to these accounting principles. The research methods used in analyzing the principles are: documentation of theoretical study of normative acts in the field of accounting, observation, comparative analysis, synthesis, information classification and data interpretation.

  16. Trends in compensation for deaths from occupational cancer in Canada: a descriptive study.

    Science.gov (United States)

    Del Bianco, Ann; Demers, Paul A

    2013-09-01

    Occupational cancer is the leading cause of work-related deaths, yet it is often unrecognized and under reported, and associated claims for compensation go unfiled. We sought to examine trends in deaths from occupational cancer, high-risk industries and exposures, and commonly compensated categories of occupational cancers. In addition, we compared deaths from occupational lung cancer for which compensation had been given with total deaths from lung cancer. We used data from the Association of Workers' Compensation Boards of Canada pertaining to the nature and source of the injury or disease and the industry in which it occurred (by jurisdiction) to describe trends in compensated claims for deaths from occupational cancer in Canada for the period 1997-2010. We used data published by the Canadian Cancer Society in Canadian Cancer Statistics to compare compensated occupational lung cancer deaths with total estimated lung cancer deaths for the period between 2006 and 2010. Compensated claims for deaths from occupational cancer have increased in recent years and surpassed those for traumatic injuries and disorders in Canada, particularly in Ontario. Between 1997 and 2010, one-half of all compensated deaths from occupational cancer in Canada were from Ontario. High-risk industries for occupational cancer include manufacturing, construction, mining and, more recently, government services. Deaths from lung cancer and mesothelioma comprise most of the compensated claims for deaths from occupational cancer in Ontario and Canada. These diseases are usually the result of asbestos exposure. The burden of other occupational carcinogens is not reflected in claims data. Although the number of accepted claims for deaths from occupational cancers has increased in recent years, these claims likely only represent a fraction of the true burden of this problem. Increased education of patients, workers at high risk of exposure and health care providers is needed to ensure that people

  17. Electrohydrodynamic emitters of ion beams

    International Nuclear Information System (INIS)

    Dudnikov, V.G.; Shabalin, A.L.

    1990-01-01

    Physical processes determining generation of ion beams with high emission current density in electrohydrodynamic emitters are considered. Electrohydrodynamic effects developing in ion emission features and kinetics of ion interaction in beams with high density are discussed. Factors determining the size of the emission zone, emission stability at high and low currents, cluster generation, increase of energy spread and decrease of brightness are analyzed. Problems on practical provision of stable EHD emitter functioning are considered. 94 refs.; 8 figs.; 1 tab

  18. Diamondoid monolayers as electron emitters

    Science.gov (United States)

    Yang, Wanli [El Cerrito, CA; Fabbri, Jason D [San Francisco, CA; Melosh, Nicholas A [Menlo Park, CA; Hussain, Zahid [Orinda, CA; Shen, Zhi-Xun [Stanford, CA

    2012-04-10

    Provided are electron emitters based upon diamondoid monolayers, preferably self-assembled higher diamondoid monolayers. High intensity electron emission has been demonstrated employing such diamondoid monolayers, particularly when the monolayers are comprised of higher diamondoids. The application of such diamondoid monolayers can alter the band structure of substrates, as well as emit monochromatic electrons, and the high intensity electron emissions can also greatly improve the efficiency of field-effect electron emitters as applied to industrial and commercial applications.

  19. A device for electron gun emittance measurement

    International Nuclear Information System (INIS)

    Aune, B.; Corveller, P.; Jablonka, M.; Joly, J.M.

    1985-05-01

    In order to improve the final emittance of the beam delivered by the ALS electron linac a new gun is going to be installed. To measure its emittance and evaluate the contribution of different factors to emittance growth we have developed an emittance measurement device. We describe the experimental and mathematical procedure we have followed, and give some results of measurements

  20. Emittance variations in current-amplifying ion induction linacs

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1991-01-01

    Since 1985 the Heavy Ion Fusion Accelerator Research program at the Lawrence Berkeley Laboratory has been studying current amplification and emittance variations in MBE-4, a four-cesium-beam induction linac. This experiment models much of the accelerator physics of the electrostatically focused section of a fusion driver. Four space-charge dominated Cs + beams, initially about one meter in length at currents of 5-10 mA, are focused by electrostatic quadrupoles and accelerated in parallel from approximately 200 keV up to one MeV by 24 accelerating gaps. Final currents of 20-40 mA per beam are typical. Recent experiments with extremely low emittance beams (var-epsilon n =0.03 mm-mRad) have investigated variations of transverse and longitudinal normalized emittance for drifting and accelerating beams. These very strongly tune-depressed beams (σ 0 =72 degree, σ∼6 degree) are difficult to match to the accelerator so as to avoid emittance growth during acceleration. During transport strong emittance fluctuations are observed in good qualitative agreement with simulations. Warmer beams with less tune depression exhibit little to no emittance growth, show smaller emittance fluctuations, and are much easier to match. A summary of findings from the MBE-4 studies is presented

  1. Emittance variations in current-amplifying ion induction linacs

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1991-04-01

    Since 1985 the Heavy Ion Fusion Accelerator Research program at the Lawrence Berkeley Laboratory has been studying current amplification and emittance variations in MBE-4, a four-cesium-beam induction linac. This experiment models much of the accelerator physics of the electrostatically focused section of a fusion driver. Four space-charge dominated Cs + beams, initially about one meter in length at currents of 5--10 mA, are focused by electrostatic quadrupoles and accelerated in parallel from approximately 200 keV up to one MeV by 24 accelerating gaps. Final currents of 20--40 mA per beam are typical. Recent experiments with extremely low emittance beams (ε n = 0.03 mm-mRad) have investigated variations of transverse and longitudinal normalized emittance for drifting and accelerating beams. These very strongly tune-depressed beams (σ o = 72 degrees, σ∼6 degree) are difficult to match the accelerator so as to avoid emittance growth during acceleration. During transport strong emittance fluctuations are observed in good qualitative agreement with simulations. Warmer beams with less tune depression exhibit little to no emittance growth, show smaller emittance fluctuations, and are much easier to match. A summary of findings from the MBE-4 studies is presented. 12 refs., 8 figs

  2. [Ecological compensation based on farmers' willingness: A case study of Jingsan County in Hubei Province, China].

    Science.gov (United States)

    Yu, Liang-liang; Cai, Yin-ying

    2015-01-01

    Farmland protection is a pressing issue in China' s major agricultural regions because of the strategic importance of these regions for national food security. This study quantified the appropriate ecological compensation criteria for farmland protection by way of estimating farmers' opportunity cost and willingness to adopt environment-friendly farming practices. Based on survey data collected from Jingsan County, Hubei Province, a Tobit model was constructed to identify factors affecting farmers' willingness to accept (WTA). The result showed that with appropriate economic compensation for farmland protection, 77.1% and 64.7% of the surveyed households were willing to reduce usage of fertilizers and pesticides. When the reduced rates of fertilizer and pesticide increased from 50%, farmers' opportunity costs of production respectively increased from 1198 and 5850 yuan to 9698 and 9750 yuan per hectare per year, and their WTA increased from 4750 and 7313 yuan to 9781 and 12393 yuan per hectare per year. Farmers' opportunity cost and WTA in reducing pesticide inputs were larger than those in reducing the same rate of fertilizer inputs, and in each case farmers' WTA was greater than their opportunity cost. A farm' s distance from township, farmers' knowledge about the ecology of farmland, and their expectation to improve the ecological environment of farmland had positive, significant effect on the farmers' WTA to reducing fertilization, while farmers' education level and the overall economic condition of the village had significantly negative effect. The proportion of agriculture income, farmers' knowledge about the ecology of farmland, and their expectation to improve the ecological environment of farmland had positive, significant effect on the farmers' WTA to reducing pesticide, while household' cash income and the overall economic condition of the village had significantly negative effect.

  3. Creative compensation

    Energy Technology Data Exchange (ETDEWEB)

    Coll, D

    1994-09-19

    A discussion is presented of executive compensation in Canada's petroleum industry. Mandatory disclosure of executive compensation and benefits is regulated by the Ontario Securities Commission. Examination of the compensation packages of 80 oilpatch CEOs shows a clear difference in philosophy between large and small companies. Larger companies pay larger salaries, offer pension plans, and reward long-term loyalty. Within smaller companies, compensation tends to be linked with stock performance. Trends in compensation are to lower base salaries with more variables such as bonuses, cash incentives and gain-sharing programs. Increasing shareholder scrutiny is prompting more stringent guidelines on stock option plans. Some companies place performance conditions on stock vesting. Another option is to grant premium priced options to executives, to increase the gains required for the executive to post a profit. Other comapanies are granting stock options to their field personnel, or are granting stock to all employees. Directors are playing an increasing role in executive compensation. 4 tabs.

  4. Study on APD real time compensation methods of laser Detection system

    International Nuclear Information System (INIS)

    Feng Ying; Zhang He; Zhang Xiangjin; Liu Kun

    2011-01-01

    With the monochromatic and the directional capability of the laser, laser detection system is confidential in anti-jamming. Detection accuracy is improved significantly as the result of laser's good orientation ability. Sensitivity is enhanced as laser's high-brightness characteristic. With the development of laser technology and laser devices, laser detections are developed both in civilian and military areas. In the military field, laser detection system has been widely applied in various types of tactical missiles, the technique is more mature. Because photo detectors receive the backscattering echo signal of target in laser detection system, they are required sensitive enough to weak signal. With APD's salient features of high sensitivity, rapid response speed, high response frequency and low noise equivalent power, etc.; PIN is replaced by APD to improve sensitivity of laser detection system in recent years. The signal magnification is inadequate in laser detection system, the detector output is usually amplified by multistage amplifiers. And then the system noise includes detector noise and latter amplifiers noise. With its high internal gain, APD becomes the primary noise source of receiving system. This point can be attested by analyzing the transfer function of laser detection system receiver. To ensure the system detecting ability, APD noise must be mitigated as low as possible. According to a large number of experiments, the power signal-to-noise (SNR) and the best multiplication factor of APD are mostly affected by background radiation and temperature. In order to make APD operate at state of the best multiplication factor, the optimum bias must be selected due to the actual operating circumstance. Therefore, APD realtime compensation must be adopted. The existing APD compensation includes the constant false alarm rate compensation, the noise compensation and the temperature compensation. The features of these compensations are obtained by analyzing

  5. Study on APD real time compensation methods of laser Detection system

    Energy Technology Data Exchange (ETDEWEB)

    Feng Ying; Zhang He; Zhang Xiangjin; Liu Kun, E-mail: fy_caimi@163.com [ZNDY of Ministerial Key Laboratory, Nanjing University of Science and Technology, Nanjing 210094 (China)

    2011-02-01

    With the monochromatic and the directional capability of the laser, laser detection system is confidential in anti-jamming. Detection accuracy is improved significantly as the result of laser's good orientation ability. Sensitivity is enhanced as laser's high-brightness characteristic. With the development of laser technology and laser devices, laser detections are developed both in civilian and military areas. In the military field, laser detection system has been widely applied in various types of tactical missiles, the technique is more mature. Because photo detectors receive the backscattering echo signal of target in laser detection system, they are required sensitive enough to weak signal. With APD's salient features of high sensitivity, rapid response speed, high response frequency and low noise equivalent power, etc.; PIN is replaced by APD to improve sensitivity of laser detection system in recent years. The signal magnification is inadequate in laser detection system, the detector output is usually amplified by multistage amplifiers. And then the system noise includes detector noise and latter amplifiers noise. With its high internal gain, APD becomes the primary noise source of receiving system. This point can be attested by analyzing the transfer function of laser detection system receiver. To ensure the system detecting ability, APD noise must be mitigated as low as possible. According to a large number of experiments, the power signal-to-noise (SNR) and the best multiplication factor of APD are mostly affected by background radiation and temperature. In order to make APD operate at state of the best multiplication factor, the optimum bias must be selected due to the actual operating circumstance. Therefore, APD realtime compensation must be adopted. The existing APD compensation includes the constant false alarm rate compensation, the noise compensation and the temperature compensation. The features of these compensations are obtained

  6. Study on APD real time compensation methods of laser Detection system

    Science.gov (United States)

    Ying, Feng; He, Zhang; Xiangjin, Zhang; Kun, Liu

    2011-02-01

    With the monochromatic and the directional capability of the laser, laser detection system is confidential in anti-jamming. Detection accuracy is improved significantly as the result of laser's good orientation ability. Sensitivity is enhanced as laser's high-brightness characteristic. With the development of laser technology and laser devices, laser detections are developed both in civilian and military areas. In the military field, laser detection system has been widely applied in various types of tactical missiles, the technique is more mature. Because photo detectors receive the backscattering echo signal of target in laser detection system, they are required sensitive enough to weak signal. With APD's salient features of high sensitivity, rapid response speed, high response frequency and low noise equivalent power, etc.; PIN is replaced by APD to improve sensitivity of laser detection system in recent years. The signal magnification is inadequate in laser detection system, the detector output is usually amplified by multistage amplifiers. And then the system noise includes detector noise and latter amplifiers noise. With its high internal gain, APD becomes the primary noise source of receiving system. This point can be attested by analyzing the transfer function of laser detection system receiver. To ensure the system detecting ability, APD noise must be mitigated as low as possible. According to a large number of experiments, the power signal-to-noise (SNR) and the best multiplication factor of APD are mostly affected by background radiation and temperature. In order to make APD operate at state of the best multiplication factor, the optimum bias must be selected due to the actual operating circumstance. Therefore, APD realtime compensation must be adopted. The existing APD compensation includes the constant false alarm rate compensation, the noise compensation and the temperature compensation. The features of these compensations are obtained by analyzing

  7. SU-F-T-533: Study of Dosimetric Properties of Cadmium Free Alloy Used in Compensator Based IMRT

    Energy Technology Data Exchange (ETDEWEB)

    Tyagi, A [Dr B L Kapoor Hospital, New Delhi, Delhi (India); Kaushik, S [Dr B L Kapoor Hospital, New Delhi, Delhi (India); Guru Jambheshwar University of Science & Technology, Hisar, Haryana (India); Punia, R [Guru Jambheshwar University of Science & Technology, Hisar, Haryana (India); Singh, M [MMH College, Ghaziabad, Utter Pradesh (India)

    2016-06-15

    Purpose: To study the dosimetric properties of cadmium free alloy which is used in compensator based IMRT. Methods: A mixture of 30% of lead,52% of bismuth and 18% of tin was used to prepare alloy. We prepared slabs of different thicknesses ranging from 0.71 cm to 6.14 cm. Density of alloy was measured by Archimedes’ principle using SI-234 Denver instrument and water as buoyant liquid. Transmission, linear attenuation coefficient (µ), tissue phantom ration (TPR), beam hardening, surface dose (Ds), percentage depth dose (PDD) and effect of scatter were measured and analyze for different field size and different thickness of compensator for 6 MV photon beam. Measurements were carried out at 100 cm SSD and 160 cm SSD. Results: Density of alloy was found to be 9.5456 gm/cm3. Melting point of alloy is 90–95 °C. For a field size of 10×10 cm2 µ was 0.4253 cm-1 at 100 cm SSD. Calculated TPR was found to be within 3 % of measured TPR. Ds was found to be decreasing with increasing thickness of compensator. 1cm, 1.98 cm and 4.16 cm thick compensator slab decreased surface dose by 4.2%, 6.1% and 9.5% respectively for a field size of 10×10cm2 at 100 cm SSD. As field size increases Ds increases for a given compensator thickness. This is due to increase in amount of scattered dose from wider collimator opening. For smaller field size, PDDs are increased from 3.0% to 5.5% of open beam PDDs as compensator thickness increases from 1 cm to 6.14 cm at a depth of 10 cm in water. For larger field size variation in PDDs is not significant. Conclusion: High degree of modulation can be achieved from this compensator material, which is essential in compensator based IMRT. Dosimetric properties analyzed in this study establish this alloy as a reliable, cost effective, reusable compensator material.

  8. Radiobiological compensation: A case study of uterine cervix cancer with concurrent chemotherapy

    International Nuclear Information System (INIS)

    Herrera, Higmar; Yañez, Elvia; López, Jesús

    2012-01-01

    The case of a patient diagnosed with uterine cervix cancer is presented as an example of the clinical application of the radiobiological compensation method implemented at Centro Estatal de Cancerología de Durango. Radiotherapy treatment was initially modified to compensate for the chemotherapy component and, as medical complications arose during treatment delivery resulting in an 18 days gap, new compensation followed. All physical and radiobiological assumptions to calculate the Biologically Effective Dose in the external beam and brachytherapy parts of the treatment are presented. Good local control of the tumor was achieved, the theoretical tolerance limits for the organs at risk were not surpassed and the patient manifested no extensive morbidity.

  9. Radiobiological compensation: A case study of uterine cervix cancer with concurrent chemotherapy

    Science.gov (United States)

    Herrera, Higmar; Yañez, Elvia; López, Jesús

    2012-10-01

    The case of a patient diagnosed with uterine cervix cancer is presented as an example of the clinical application of the radiobiological compensation method implemented at Centro Estatal de Cancerología de Durango. Radiotherapy treatment was initially modified to compensate for the chemotherapy component and, as medical complications arose during treatment delivery resulting in an 18 days gap, new compensation followed. All physical and radiobiological assumptions to calculate the Biologically Effective Dose in the external beam and brachytherapy parts of the treatment are presented. Good local control of the tumor was achieved, the theoretical tolerance limits for the organs at risk were not surpassed and the patient manifested no extensive morbidity.

  10. Radiobiological compensation: A case study of uterine cervix cancer with concurrent chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, Higmar; Yanez, Elvia; Lopez, Jesus [Centro Estatal de Cancerologia de Durango, Victoria de Durango, Durango (Mexico); ISSSTE General Hospital Dr. Santiago Ramon y Cajal, Victoria de Durango, Durango (Mexico)

    2012-10-23

    The case of a patient diagnosed with uterine cervix cancer is presented as an example of the clinical application of the radiobiological compensation method implemented at Centro Estatal de Cancerologia de Durango. Radiotherapy treatment was initially modified to compensate for the chemotherapy component and, as medical complications arose during treatment delivery resulting in an 18 days gap, new compensation followed. All physical and radiobiological assumptions to calculate the Biologically Effective Dose in the external beam and brachytherapy parts of the treatment are presented. Good local control of the tumor was achieved, the theoretical tolerance limits for the organs at risk were not surpassed and the patient manifested no extensive morbidity.

  11. Part-time physician faculty in a pediatrics department: a study of equity in compensation and academic advancement.

    Science.gov (United States)

    Darbar, Mumtaz; Emans, S Jean; Harris, Z Leah; Brown, Nancy J; Scott, Theresa A; Cooper, William O

    2011-08-01

    To assess equity in compensation and academic advancement in an academic pediatrics department in which a large proportion of the physician faculty hold part-time appointments. The authors analyzed anonymized data from Vanderbilt University School of Medicine Department of Pediatrics databases for physician faculty (faculty with MD or MD/PhD degrees) employed during July 1, 2007 to June 30, 2008. The primary outcomes were total compensation and years at assistant professor rank. They compared compensation and years at junior rank by part-time versus full-time status, controlling for gender, rank, track, years since first appointment as an assistant professor, and clinical productivity. Of the 119 physician faculty in the department, 112 met inclusion criteria. Among those 112 faculty, 23 (21%) were part-time and 89 (79%) were full-time faculty. Part-time faculty were more likely than full-time faculty to be women (74% versus 28%, P part-time versus full-time status. In other adjusted analyses, faculty with part-time appointments spent an average of 2.48 more years as an assistant professor than did faculty with full-time appointments. Overall group differences in total compensation were not apparent in this department, but physician faculty with part-time appointments spent more time at the rank of assistant professor. This study provides a model for determining and analyzing compensation and effort to ensure equity and transparency across faculty.

  12. Progress on low emittance tuning for the CLIC Damping Rings

    CERN Document Server

    Alabau-Gonzalvo, J; Papaphilippou, Y

    2014-01-01

    In the frame of the CLIC main Damping Ring a study on the sensitivity of the lattice to different sources of misalignment is presented. The minimum equilibrium emittance is simulated and analytically estimated under dipole and quadrupole rolls, and quadrupole and sextupole vertical offsets. The result of this study establishes alignment tolerances to preserve the vertical emittance below the design value (1 pmrad). Non-linear dynamics studies have been done to determine the dynamic aperture in the presence of misalignments.

  13. Study of Thermal-Field Emission Properties and Investigation of Temperature dependent Noise in the Emission Current form vertical Carbon nanotube emitters

    KAUST Repository

    Kolekar, Sadhu

    2017-05-05

    We have investigated temperature dependent field electron emission characteristics of vertical carbon nanotubes (CNTs). The generalized expression for electron emission from well defined cathode surface is given by Millikan and Lauritsen [1] for the combination of temperature and electric field effect. The same expression has been used to explain the electron emission characteristics from vertical CNT emitters. Furthermore, this has been applied to explain the electron emission for different temperatures ranging from room temperature to 1500 K. The real-time field electron emission images at room temperature and 1500 K are recorded by using Charge Coupled Device (CCD), in order to understand the effect of temperature on electron emission spots in image morphology (as indicated by ring like structures) and electron emission spot intensity of the emitters. Moreover, the field electron emission images can be used to calculate the total number of emitters per cm2 for electron emission. The calculated number of emitters per cm2 is 4.5x107 and, the actual number emitters per cm2 present for electron emission calculated from Atomic Force Microscopy (AFM) data is 1.2x1012. The measured Current-Voltage (I-V) characteristics obey the Folwer-Nordheim (F-N) type behavior. The fluctuations in the emission current are recorded at different temperatures and, temperature dependence of power spectral density obeys power law relation s(f)=I2/f2 with that of emission current and frequency.

  14. Mesoscopic quantum emitters coupled to plasmonic nanostructures

    DEFF Research Database (Denmark)

    Andersen, Mads Lykke

    for the spontaneous emission of mesoscopic quantum emitters is developed. The light-matter interaction is in this model modied beyond the dipole expectancy and found to both suppress and enhance the coupling to plasmonic modes in excellent agreement with our measurements. We demonstrate that this mesoscopic effect......This thesis reports research on quantum dots coupled to dielectric and plasmonic nano-structures by way of nano-structure fabrication, optical measurements, and theoretical modeling. To study light-matter interaction, plasmonic gap waveguides with nanometer dimensions as well as samples for studies...... to allow for e- cient plasmon-based single-photon sources. Theoretical studies of coupling and propagation properties of plasmonic waveguides reveal that a high-refractive index of the medium surrounding the emitter, e.g. nGaAs = 3.5, limits the realizability of ecient plasmon-based single-photon sources...

  15. Study on the compensation of electron beam space charge in facilittes with electron cooling

    International Nuclear Information System (INIS)

    Dikanskij, N.S.; Kudelajnen, V.I.; Parkhomchuk, V.V.; Pestrikov, D.V.

    1981-01-01

    The results of experimental investigations of a compensated electron beam on the NAP-M facility are presented. The electron beam is compensated by electrostatic plugs preventing ion leakage along the beam. Cut-off electrodes have the shape of cutted cylinders encircling the electron beam. To eliminate electron accumulation around the plugs one of the electrodes has a zero potential, which results in formation of an transverse electric field causing ionization electron drift in the transverse direction to the electric and magnetic fields. The effect of wave damping, in the compensated beam is observed, that demonstrates the possibility of gaining great current densities in long compensated beams necessary for antiproton storage. For the NAP-M at the 10 10 cm/s electron velocity, 300 cm length of ion column, and 1 kOe field intensity the threshold beam current density is 0.96 A/cm 2 [ru

  16. The effects of performance measurement and compensation on motivation : an empirical study

    NARCIS (Netherlands)

    van Herpen, M.; van Praag, M.; Cools, K.

    2005-01-01

    This paper analyzes empirically the relationship between pay and performance. Economic and psychological theories predict that the design and implementation of a performance measurement and compensation system affect the motivation of employees. Our survey results demonstrate a positive relationship

  17. The effects of performance measurement and compensation on motivation : An empirical study

    NARCIS (Netherlands)

    Van Herpen, M; Van Praag, M; Cools, K

    This paper analyzes empirically the relationship between pay and performance. Economic and psychological theories predict that the design and implementation of a performance measurement and compensation system affect the motivation of employees. Our survey results demonstrate a positive relationship

  18. Few emitters in a cavity: from cooperative emission to individualization

    International Nuclear Information System (INIS)

    Auffeves, A; Portolan, S; Gerace, D; Drezet, A; Franca Santos, M

    2011-01-01

    We study the temporal correlations of the field emitted by an electromagnetic resonator coupled to a mesoscopic number of two-level emitters that are incoherently pumped by a weak external drive. We solve the master equation of the system for increasing number of emitters and as a function of the cavity quality factor, and we identify three main regimes characterized by well-distinguished statistical properties of the emitted radiation. For small cavity decay rates, the emission events are uncorrelated and the number of photons in the emitted field becomes larger than one, resembling the build-up of a laser field inside the cavity. At intermediate decay rates (as compared with the emitter-cavity coupling) and for a few emitters, the statistics of the emitted radiation is bunched and strikingly dependent on the parity of the number of emitters. The latter property is related to the cooperativity of the emitters mediated by their coupling to the cavity mode, and its connection with steady-state subradiance is discussed. Finally, in the bad cavity regime the typical situation of emission from a collection of individual emitters is recovered. We also analyze how the cooperative behavior evolves as a function of pure dephasing, which allows us to recover the case of a classical source made of an ensemble of independent emitters, similar to what is obtained for a very leaky cavity. State-of-the-art techniques of Q-switch of resonant cavities, allied with the recent capability of tuning single emitters in and out of resonance, suggest this system to be a versatile source of different quantum states of light.

  19. Few emitters in a cavity: from cooperative emission to individualization

    Energy Technology Data Exchange (ETDEWEB)

    Auffeves, A; Portolan, S [CEA/CNRS/UJF Joint Team ' Nanophysics and Semiconductors' , Institut Neel-CNRS, BP 166, 25 Rue des Martyrs, 38042 Grenoble Cedex 9 (France); Gerace, D [Dipartimento di Fisica ' Alessandro Volta' and UdR CNISM, Universita di Pavia, via Bassi 6, 27100 Pavia (Italy); Drezet, A [Institut Neel-CNRS, BP 166, 25 Rue des Martyrs, 38042 Grenoble Cedex 9 (France); Franca Santos, M, E-mail: msantos@fisica.ufmg.br [Departamento de Fisica, Universidade Federal de Minas Gerais, Belo Horizonte, CP 702, 30123-970 (Brazil)

    2011-09-15

    We study the temporal correlations of the field emitted by an electromagnetic resonator coupled to a mesoscopic number of two-level emitters that are incoherently pumped by a weak external drive. We solve the master equation of the system for increasing number of emitters and as a function of the cavity quality factor, and we identify three main regimes characterized by well-distinguished statistical properties of the emitted radiation. For small cavity decay rates, the emission events are uncorrelated and the number of photons in the emitted field becomes larger than one, resembling the build-up of a laser field inside the cavity. At intermediate decay rates (as compared with the emitter-cavity coupling) and for a few emitters, the statistics of the emitted radiation is bunched and strikingly dependent on the parity of the number of emitters. The latter property is related to the cooperativity of the emitters mediated by their coupling to the cavity mode, and its connection with steady-state subradiance is discussed. Finally, in the bad cavity regime the typical situation of emission from a collection of individual emitters is recovered. We also analyze how the cooperative behavior evolves as a function of pure dephasing, which allows us to recover the case of a classical source made of an ensemble of independent emitters, similar to what is obtained for a very leaky cavity. State-of-the-art techniques of Q-switch of resonant cavities, allied with the recent capability of tuning single emitters in and out of resonance, suggest this system to be a versatile source of different quantum states of light.

  20. Emittance growth in coast in the SPS

    CERN Document Server

    Alekou, A; Bartosik, H; Calaga, R

    2017-01-01

    The CERN SPS will be used as a test-bed for the LHCprototype crab-cavities, which will be installed and testedin the SPS in 2018. As the time available for experimen-tal beam dynamics studies with the crab cavities installedin the machine will be limited, a very good preparation isrequired in advance. One of the main concerns is the in-duced emittance growth, driven by phase jitter in the crabcavities. In this respect, several machine development (MD)studies were performed during the past years to quantifyand characterize the emittance evolution of proton beamsin coast in the SPS. In these proceedings, the experimentalobservations from past years are summarized and the MDstudies from 2016 are presented. Finally, a proposal for anexperimental program for 2017 is discussed.

  1. Compensation Consultants and CEO Pay

    NARCIS (Netherlands)

    Kabir, Mohammed Rezaul; Minhat, Marizah

    2014-01-01

    The study examines the practice of employing multiple compensation consultants. Examining data of a sample of UK companies over the period 2003–2006 we find that CEOs receive higher equity-based pay when firms employ more than one compensation consultant. An increase in the number of compensation

  2. Management accounting approach to analyse energy related CO2 emission: A variance analysis study of top 10 emitters of the world

    International Nuclear Information System (INIS)

    Pani, Ratnakar; Mukhopadhyay, Ujjaini

    2013-01-01

    The paper undertakes a decomposition study of carbon dioxide emission of the top ten emitting countries over the period 1980–2007 using variance analysis method, with the objectives of examining the relative importance of the major determining factors, the role of energy structure and impact of liberalisation on emission and exploring the possibilities of arresting emission with simultaneous rise in population and income. The major findings indicate that although rising income and population are the main driving forces, they are neither necessary nor sufficient for increasing emission, rather energy structure and emission intensities are the crucial determinants, pointing towards the fact that a country with higher income and population with proper energy policy may be a low emitter and vice-versa. Since modern energy-intensive production limits the scope of reduction in total energy use, it is necessary to decouple the quantum of energy use from emission through technological upgradation. The results indicate that liberalisation resulted in higher emission. The paper attempts to illustrate the required adjustments in energy structure and suggests necessary policy prescriptions.

  3. Energetic studies on DNA-peptide interaction in relation to the enthalpy-entropy compensation paradox.

    Science.gov (United States)

    Yang, Robin C K; Huang, Jonathan T B; Chien, Shih-Chuan; Huang, Roy; Jeng, Kee-Ching G; Chen, Yen-Chung; Liao, Mokai; Wu, Jia-Rong; Hung, Wei-Kang; Hung, Chia-Chun; Chen, Yu-Ling; Waring, Michael J; Sheh, Leung

    2013-01-07

    This study aims to interpret the energetic basis of complex DNA-peptide interactions according to a novel allosteric interaction network approach. In common with other designed peptides, five new conjugates incorporating the XPRK or XHypRK motif (Hyp = hydroxyproline) attached to a N-methylpyrrole (Py) tract with a basic tail have been found to display cooperative binding to DNA involving multiple monodentate as well as interstrand bidentate interactions. Using quantitative DNase I footprinting it appears that allosteric communication via cooperative binding to multiple sites on complementary DNA strands corresponds to two different types of DNA-peptide interaction network. Temperature variation experiments using a dodecapeptide RY-12 show that lower temperature (25 °C) favor a circuit type of allosteric interaction network, whereas higher temperatures (31 and 37 °C) afford only a partial-circuit type of network. Circular dichroism studies show that our five peptides induce significant local conformational changes in DNA via the minor groove, with apparently dimeric binding stoichiometry. Isothermal titration calorimetry reveals that these peptides, together with another seven for comparison, are strongly exothermic upon binding to a model 13-mer DNA duplex, characterized by ΔH ranging from -14.7 to -74.4 kcal mol(-1), and also high TΔS ranging from -6.5 to -65.9 kcal mol(-1). Multiple monodentate and bidentate interactions, as well as ionic forces that mediate positive cooperativity in sequence recognition, are consistent with a dramatic decrease in entropy and a 'tightening' effect of DNA conformation. Distinctive enthalpy-entropy compensation (EEC) relationships are demonstrated for the interaction of all twelve designed peptides with DNA, affording a straight line of slope close to unity when ΔH is plotted versus TΔS, with a y-axis intercept (average ΔG) corresponding to -8.5 kcal mol(-1), while the observed ΔG ranges from -8.2 to -9.1 kcal mol(-1) for

  4. Importance of scatter compensation algorithm in heterogeneous tissue for the radiation dose calculation of small lung nodules. A clinical study

    International Nuclear Information System (INIS)

    Baba, Yuji; Murakami, Ryuji; Mizukami, Naohisa; Morishita, Shoji; Yamashita, Yasuyuki; Araki, Fujio; Moribe, Nobuyuki; Hirata, Yukinori

    2004-01-01

    The purpose of this study was to compare radiation doses of small lung nodules calculated with beam scattering compensation and those without compensation in heterogeneous tissues. Computed tomography (CT) data of 34 small (1-2 cm: 12 nodules, 2-3 cm 11 nodules, 3-4 cm 11 nodules) lung nodules were used in the radiation dose measurements. Radiation planning for lung nodule was performed with a commercially available unit using two different radiation dose calculation methods: the superposition method (with scatter compensation in heterogeneous tissues), and the Clarkson method (without scatter compensation in heterogeneous tissues). The energy of the linac photon used in this study was 10 MV and 4 MV. Monitor unit (MU) to deliver 10 Gy at the center of the radiation field (center of the nodule) calculated with the two methods were compared. In 1-2 cm nodules, MU calculated by Clarkson method (MUc) was 90.0±1.1% (4 MV photon) and 80.5±2.7% (10 MV photon) compared to MU calculated by superposion method (MUs), in 2-3 cm nodules, MUc was 92.9±1.1% (4 MV photon) and 86.6±2.8% (10 MV photon) compared to MUs, and in 3-4 cm nodules, MUc was 90.5±2.0% (4 MV photon) and 90.1±1.7% (10 MV photon) compared to MUs. In 1-2 cm nodules, MU calculated without lung compensation (MUn) was 120.6±8.3% (4 MV photon) and 95.1±4.1% (10 MV photon) compared to MU calculated by superposion method (MUs), in 2-3 cm nodules, MUc was 120.3±11.5% (4 MV photon) and 100.5±4.6% (10 MV photon) compared to MUs, and in 3-4 cm nodules, MUc was 105.3±9.0% (4 MV photon) and 103.4±4.9% (10 MV photon) compared to MUs. The MU calculated without lung compensation was not significantly different from the MU calculated by superposition method in 2-3 cm nodules. We found that the conventional dose calculation algorithm without scatter compensation in heterogeneous tissues substantially overestimated the radiation dose of small nodules in the lung field. In the calculation of dose distribution of small

  5. A Conservation-Based Approach to Compensation for Livestock Depredation: The Florida Panther Case Study.

    Science.gov (United States)

    Jacobs, Caitlin E; Main, Martin B

    2015-01-01

    Calf (Bos taurus) depredation by the federally endangered Florida panther (Puma concolor coryi) on ranches in southwest Florida is an important issue because ranches represent mixed landscapes that provide habitat critical to panther recovery. The objectives of this study were to (1) quantify calf depredation by panthers on two ranches in southwest Florida, and (2) develop a habitat suitability model to evaluate the quality of panther hunting habitat on ranchlands, assess whether the model could predict predation risk to calves, and discuss its potential to be incorporated into an incentive-based compensation program. We ear-tagged 409 calves with VHF transmitters on two ranches during 2011-2013 to document calf mortality. We developed a model to evaluate the quality of panther hunting habitat on private lands in southwest Florida using environmental variables obtained from the Florida Natural Areas Inventory (FNAI) Cooperative Landcover Database and nocturnal GPS locations of panthers provided by the Florida Fish and Wildlife Conservation Commission (FWC). We then tested whether the model could predict the location of calf depredation sites. Tagged calf loss to panthers varied between the two ranches (0.5%/yr to 5.3%/yr) and may have been influenced by the amount of panther hunting habitat on each ranch as the ranch that experienced higher depredation rates contained a significantly higher probability of panther presence. Depredation sites of tagged calves had a significantly greater probability of panther presence than depredation sites of untagged calves that were found by ranchers in open pastures. This suggests that there may be more calves killed in high risk environments than are being found and reported by ranchers and that panthers can hunt effectively in open environments. It also suggests that the model may provide a means for evaluating the quality of panther hunting habitat and the corresponding risk of depredation to livestock across the landscape. We

  6. A Conservation-Based Approach to Compensation for Livestock Depredation: The Florida Panther Case Study.

    Directory of Open Access Journals (Sweden)

    Caitlin E Jacobs

    Full Text Available Calf (Bos taurus depredation by the federally endangered Florida panther (Puma concolor coryi on ranches in southwest Florida is an important issue because ranches represent mixed landscapes that provide habitat critical to panther recovery. The objectives of this study were to (1 quantify calf depredation by panthers on two ranches in southwest Florida, and (2 develop a habitat suitability model to evaluate the quality of panther hunting habitat on ranchlands, assess whether the model could predict predation risk to calves, and discuss its potential to be incorporated into an incentive-based compensation program. We ear-tagged 409 calves with VHF transmitters on two ranches during 2011-2013 to document calf mortality. We developed a model to evaluate the quality of panther hunting habitat on private lands in southwest Florida using environmental variables obtained from the Florida Natural Areas Inventory (FNAI Cooperative Landcover Database and nocturnal GPS locations of panthers provided by the Florida Fish and Wildlife Conservation Commission (FWC. We then tested whether the model could predict the location of calf depredation sites. Tagged calf loss to panthers varied between the two ranches (0.5%/yr to 5.3%/yr and may have been influenced by the amount of panther hunting habitat on each ranch as the ranch that experienced higher depredation rates contained a significantly higher probability of panther presence. Depredation sites of tagged calves had a significantly greater probability of panther presence than depredation sites of untagged calves that were found by ranchers in open pastures. This suggests that there may be more calves killed in high risk environments than are being found and reported by ranchers and that panthers can hunt effectively in open environments. It also suggests that the model may provide a means for evaluating the quality of panther hunting habitat and the corresponding risk of depredation to livestock across the

  7. Radiation emitter-detector package

    International Nuclear Information System (INIS)

    O'Brien, J.T.; Limm, A.C.; Nyul, P.; Tassia, V.S. Jr.

    1978-01-01

    Mounted on the metallic base of a radiation emitter-detector is a mounting block is a first projection, and a second projection. A radiation detector is on the first projection and a semiconductor electroluminescent device, i.e., a radiation emitter, is on the second projection such that the plane of the recombination region of the electroluminescent device is perpendicular to the radiation incident surface of the radiation detector. The electroluminescent device has a primary emission and a secondary emission in a direction different from the primary emission. A radiation emitter-detector package as described is ideally suited to those applications wherein the secondary radiation of the electroluminescent device is fed into a feedback circuit regulating the biasing current of the electroluminescent device

  8. Legislative Study on China’s Compensation for Nuclear Damage Liability

    Directory of Open Access Journals (Sweden)

    Jiu Liu

    2018-06-01

    Full Text Available The civil nuclear industry plays an important role in improving environmental quality and safeguarding energy security in China. Nevertheless, the industry is facing a huge risk of nuclear accident damage. The legal system of nuclear damage compensation is of vital importance for the industry to address potential risks. The Nuclear Safety Law, which has recently been published in China, stipulates two articles about nuclear damage compensation in principle. However, in general, the current nuclear damage compensation legal system in China has not yet been made systematic and there are still problems, such as a lack of maneuverability and details. This paper adopts qualitative and quantitative methodologies to summarize and analyze the current legislation and regulation pertaining to civil nuclear damage compensation liability in China and analyzes the shortages and deficiencies of these rules in detail by using legal analysis methods. Suggestions to establish and perfect China’s legal system of nuclear damage compensation are proposed to safeguard the healthy development of the civil nuclear industry and remedy damages brought about by nuclear accidents. Such a legal system should contain the elements of clear legislative goals and objectives, a specific definition and scope of nuclear damage, strict and sole responsibility principles for operators, an appropriate liability amount, a stable financial guarantee for operators, and national supplementary liability.

  9. Skills and compensation strategies in adult ADHD – A qualitative study

    Science.gov (United States)

    Buadze, Anna; Dube, Anish; Eich, Dominique; Liebrenz, Michael

    2017-01-01

    Objective The primary objectives of this study were to investigate how adult patients with ADHD coped with their symptoms prior to diagnosis and treatment, what skills and compensation strategies they had developed and what their self-perceptions of these strategies were. Methods We used a qualitative approach to analyze interviews with 32 outpatients of a specialty care unit at a university hospital. Results Patients reported frequent use of diverse compensatory strategies with varying degrees of effectiveness. These were classified into five categories (organizational, motoric, attentional, social, psychopharmacological). In certain circumstances, ADHD symptoms were even perceived as useful. Conclusion Before diagnosis and treatment, patients with ADHD may develop a variety of skills to cope with their symptoms. Several of these skills are perceived as helpful. Knowledge of self-generated coping strategies may help better understand patients and their histories and thus facilitate patient cooperation. Moreover, knowing ways in which such patients cope with their symptoms may help elucidate reasons for late or under-diagnosing of the disorder. PMID:28953946

  10. Combustion powered thermophotovoltaic emitter system

    Energy Technology Data Exchange (ETDEWEB)

    McHenry, R.S. [Naval Academy, Annapolis, MD (United States). Naval Architecture, Ocean and Marine Engineering

    1995-07-01

    The US Naval Academy (USNA) has recently completed an engineering design project for a high temperature thermophotovoltaic (TPV) photon emitter. The final apparatus was to be portable, completely self contained, and was to incorporate cycle efficiency optimization such as exhaust stream recuperation. Through computer modeling and prototype experimentation, a methane fueled emitter system was designed from structural ceramic materials to fulfill the high temperature requirements necessary for high system efficiency. This paper outlines the engineering design process, discusses obstacles and solutions encountered, and presents the final design.

  11. Transverse Emittance Measurement and Preservation at the LHC

    CERN Document Server

    AUTHOR|(CDS)2082907

    The Large Hadron Collider (LHC) at CERN is a high energy storage ring that provides proton and heavy ion collisions to study fundamental particle physics. The luminosity production is closely linked to emittance preservation in the accelerator. The transverse emittance is the phase space density of the beam and should be conserved when the particle beam is transformed through the accelerator. Perturbing effects, however, can lead to emittance increase and hence luminosity degradation. Measuring the emittance growth is a complex task with high intensity beams and changing energies. The machine optics and the transverse beam size have to be measured as accurately as possible. Beta function measurements with k-modulation will be discussed. With this method the quadrupole focussing strength is varied and the resulting tune change is traced to determine the beta function at the quadrupole. A new k-modulation measurement tool was developed for the LHC. The fully automatic and online measurement system takes constra...

  12. Emittance increase caused by core depletion in collisions

    CERN Document Server

    Bruce, R

    2009-01-01

    A new effect is presented, which changes the emittance during colliding-beam operation in circular colliders. If the initial transverse distribution is Gaussian, the collision probability is much higher for particles in the core of the beam than in the tails. When small-amplitude particles are removed, the remaining ones therefore have a larger transverse emittance. This effect, called core depletion, may cause a decrease in luminosity. An approximate analytic model is developed to study the effect and benchmarked against a multiparticle tracking simulation. Finally, the time evolution of the intensity and emittances of a Pb bunch in the Large Hadron Collider (LHC) at CERN is calculated, taking into account also other processes than collisions. The results show that integrated luminosity drops by 3--4% if core depletion is taken into account. It is also found that core depletion causes the transverse emittance to be larger when more experiments are active. This observation could be checked against experimenta...

  13. List mode reconstructions for PET with motion compensation: A simulation study

    International Nuclear Information System (INIS)

    Qi, Jinyi; Huesman, Ronald H.

    2002-01-01

    Motion artifacts can be a significant factor that limits the image quality in high-resolution PET. Surveillance systems have been developed to track the movements of the subject during a scan. Development of reconstruction algorithms that are able to compensate for the subject motion will increase the potential of PET. In this paper we present a list mode likelihood reconstruction algorithm with the ability of motion compensation. The subject motion is explicitly modeled in the likelihood function. The detections of each detector pair are modeled as a Poisson process with time-varying rate function. The proposed method has several advantages over the existing methods. It uses all detected events and does not introduce any interpolation error. Computer simulations show that the proposed method can compensate simulated subject movements and that the reconstructed images have no visible motion artifacts

  14. List mode reconstruction for PET with motion compensation: A simulation study

    International Nuclear Information System (INIS)

    Qi, Jinyi; Huesman, Ronald H.

    2002-01-01

    Motion artifacts can be a significant factor that limits the image quality in high-resolution PET. Surveillance systems have been developed to track the movements of the subject during a scan. Development of reconstruction algorithms that are able to compensate for the subject motion will increase the potential of PET. In this paper we present a list mode likelihood reconstruction algorithm with the ability of motion compensation. The subject moti is explicitly modeled in the likelihood function. The detections of each detector pair are modeled as a Poisson process with time vary ingrate function. The proposed method has several advantages over the existing methods. It uses all detected events and does not introduce any interpolation error. Computer simulations show that the proposed method can compensate simulated subject movements and that the reconstructed images have no visible motion artifacts

  15. Study on A Control Method of PAPF for Resonance Damping and Harmonics Compensation in Power System

    DEFF Research Database (Denmark)

    Zhou, Fang; Wu, Longhui; Chen, Zhe

    2009-01-01

    In power system, capacitors are widely used to compensate reactive power, which generally cause resonance problems in harmonic distorted network. In this paper, A method of using a parallel active power filter (PAPF) to damp the resonances is proposed. The proposed method is compound with traditi......In power system, capacitors are widely used to compensate reactive power, which generally cause resonance problems in harmonic distorted network. In this paper, A method of using a parallel active power filter (PAPF) to damp the resonances is proposed. The proposed method is compound...... with traditional method, it shows that whether the capacitor current is included in the detecting current of PAPF or not. Also the PAPF with proposed method has strong ability in harmonic compensation. Finally, the experiment results are presented to verify the analysis....

  16. Study of the time and space distribution of β+ emitters from 80MeV/u carbon ion beam irradiation on PMMA

    International Nuclear Information System (INIS)

    Agodi, C.; Bellini, F.; Cirrone, G.A.P.; Collamati, F.; Cuttone, G.; De Lucia, E.; De Napoli, M.; Di Domenico, A.; Faccini, R.; Ferroni, F.; Fiore, S.; Gauzzi, P.; Iarocci, E.; Marafini, M.; Mattei, I.; Paoloni, A.

    2012-01-01

    Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments and the on-line knowledge of the Bragg peak position is still a matter of research. A possible technique exploits the collinear 511keV photons produced by positrons annihilation from β + emitters created by the beam. This paper reports rate measurements of the 511keV photons emitted after the interactions of a 80MeV/u fully stripped carbon ion beam at the Laboratori Nazionali del Sud (LNS) of INFN, with a poly-methyl methacrylate target. The time evolution of the β + rate was parametrized and the dominance of 11 C emitters over the other species ( 13 N, 15 O, 14 O) was observed, measuring the fraction of carbon ions activating β + emitters to be (10.3±0.7)×10 -3 . The average depth in the PMMA of the positron annihilation from β + emitters was also measured, D β + =5.3±1.1mm, to be compared to the expected Bragg peak depth D Bragg =11.0±0.5mm obtained from simulations.

  17. Study of the time and space distribution of {beta}{sup +} emitters from 80MeV/u carbon ion beam irradiation on PMMA

    Energy Technology Data Exchange (ETDEWEB)

    Agodi, C. [Laboratori Nazionali del Sud dell' INFN, Catania (Italy); Bellini, F. [Dipartimento di Fisica, Sapienza Universita di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Cirrone, G.A.P. [Laboratori Nazionali del Sud dell' INFN, Catania (Italy); Collamati, F. [Dipartimento di Fisica, Sapienza Universita di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Cuttone, G. [Laboratori Nazionali del Sud dell' INFN, Catania (Italy); De Lucia, E. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); De Napoli, M. [Laboratori Nazionali del Sud dell' INFN, Catania (Italy); Di Domenico, A.; Faccini, R.; Ferroni, F. [Dipartimento di Fisica, Sapienza Universita di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Fiore, S. [Dipartimento di Fisica, Sapienza Universita di Roma, Roma (Italy); Gauzzi, P. [Dipartimento di Fisica, Sapienza Universita di Roma, Roma (Italy); INFN Sezione di Roma, Roma (Italy); Iarocci, E. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Dipartimento di Scienze di Base e Applicate per l' Ingegneria, Sapienza Universita di Roma, Roma (Italy); Marafini, M., E-mail: michela.marafini@roma1.infn.it [Museo Storico della Fisica e Centro Studi e Ricerche ' E. Fermi' , Roma (Italy); Mattei, I. [Dipartimento di Fisica, Roma Tre Universita di Roma, Roma (Italy); Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Paoloni, A. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); and others

    2012-07-15

    Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments and the on-line knowledge of the Bragg peak position is still a matter of research. A possible technique exploits the collinear 511keV photons produced by positrons annihilation from {beta}{sup +} emitters created by the beam. This paper reports rate measurements of the 511keV photons emitted after the interactions of a 80MeV/u fully stripped carbon ion beam at the Laboratori Nazionali del Sud (LNS) of INFN, with a poly-methyl methacrylate target. The time evolution of the {beta}{sup +} rate was parametrized and the dominance of {sup 11}C emitters over the other species ({sup 13}N, {sup 15}O, {sup 14}O) was observed, measuring the fraction of carbon ions activating {beta}{sup +} emitters to be (10.3{+-}0.7) Multiplication-Sign 10{sup -3}. The average depth in the PMMA of the positron annihilation from {beta}{sup +} emitters was also measured, D{sub {beta}{sup +}}=5.3{+-}1.1mm, to be compared to the expected Bragg peak depth D{sub Bragg}=11.0{+-}0.5mm obtained from simulations.

  18. Compensation of kinematic geometric parameters error and comparative study of accuracy testing for robot

    Science.gov (United States)

    Du, Liang; Shi, Guangming; Guan, Weibin; Zhong, Yuansheng; Li, Jin

    2014-12-01

    Geometric error is the main error of the industrial robot, and it plays a more significantly important fact than other error facts for robot. The compensation model of kinematic error is proposed in this article. Many methods can be used to test the robot accuracy, therefore, how to compare which method is better one. In this article, a method is used to compare two methods for robot accuracy testing. It used Laser Tracker System (LTS) and Three Coordinate Measuring instrument (TCM) to test the robot accuracy according to standard. According to the compensation result, it gets the better method which can improve the robot accuracy apparently.

  19. Feasibility study and marketing strategy for climate compensated products; Haalbaarheidsonderzoek en marketingstrategie voor klimaatgecompenseerde producten

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, H.C.; Van Boetzelaer, J.C.S.

    2000-05-01

    Energy conservation and other options to reduce the emission of greenhouse gases are important aspects in climatic change policy. In order to offer consumers choices for such options the Dutch Ministry of Housing, Spatial Planning and Environment (VROM) a number of tools and ideas have been developed. In this report the feasibility of so-called climatic change compensation for consumer products is determined and a marketing communication strategy elaborated for two products: 'green' (i.e. environment-friendly) petrol and a 'climate broker', who can help suppliers of consumer products to buy and sell (marketing) climate compensated products. 13 refs.

  20. A Study of Dispersion Compensation of Polarization Multiplexing-Based OFDM-OCDMA for Radio-over-Fiber Transmissions.

    Science.gov (United States)

    Yen, Chih-Ta; Chen, Wen-Bin

    2016-09-07

    Chromatic dispersion from optical fiber is the most important problem that produces temporal skews and destroys the rectangular structure of code patterns in the spectra-amplitude-coding-based optical code-division multiple-access (SAC-OCDMA) system. Thus, the balance detection scheme does not work perfectly to cancel multiple access interference (MAI) and the system performance will be degraded. Orthogonal frequency-division multiplexing (OFDM) is the fastest developing technology in the academic and industrial fields of wireless transmission. In this study, the radio-over-fiber system is realized by integrating OFDM and OCDMA via polarization multiplexing scheme. The electronic dispersion compensation (EDC) equalizer element of OFDM integrated with the dispersion compensation fiber (DCF) is used in the proposed radio-over-fiber (RoF) system, which can efficiently suppress the chromatic dispersion influence in long-haul transmitted distance. A set of length differences for 10 km-long single-mode fiber (SMF) and 4 km-long DCF is to verify the compensation scheme by relative equalizer algorithms and constellation diagrams. In the simulation result, the proposed dispersion mechanism successfully compensates the dispersion from SMF and the system performance with dispersion equalizer is highly improved.

  1. A Study of Dispersion Compensation of Polarization Multiplexing-Based OFDM-OCDMA for Radio-over-Fiber Transmissions

    Directory of Open Access Journals (Sweden)

    Chih-Ta Yen

    2016-09-01

    Full Text Available Chromatic dispersion from optical fiber is the most important problem that produces temporal skews and destroys the rectangular structure of code patterns in the spectra-amplitude-coding-based optical code-division multiple-access (SAC-OCDMA system. Thus, the balance detection scheme does not work perfectly to cancel multiple access interference (MAI and the system performance will be degraded. Orthogonal frequency-division multiplexing (OFDM is the fastest developing technology in the academic and industrial fields of wireless transmission. In this study, the radio-over-fiber system is realized by integrating OFDM and OCDMA via polarization multiplexing scheme. The electronic dispersion compensation (EDC equalizer element of OFDM integrated with the dispersion compensation fiber (DCF is used in the proposed radio-over-fiber (RoF system, which can efficiently suppress the chromatic dispersion influence in long-haul transmitted distance. A set of length differences for 10 km-long single-mode fiber (SMF and 4 km-long DCF is to verify the compensation scheme by relative equalizer algorithms and constellation diagrams. In the simulation result, the proposed dispersion mechanism successfully compensates the dispersion from SMF and the system performance with dispersion equalizer is highly improved.

  2. Experimental investigation of thermal emittance components of copper photocathode

    Directory of Open Access Journals (Sweden)

    H. J. Qian

    2012-04-01

    Full Text Available With progress of photoinjector technology, thermal emittance has become the primary limitation of electron beam brightness. Extensive efforts have been devoted to study thermal emittance, but experiment results differ between research groups and few can be well interpreted. Besides the ambiguity of photoemission mechanism, variations of cathode surface conditions during cathode preparation, such as work function, field enhancement factor, and surface roughness, will cause thermal emittance differences. In this paper, we report an experimental study of electric field dependence of copper cathode quantum efficiency (QE and thermal emittance in a radio frequency (rf gun, through which in situ cathode surface parameters and thermal emittance contributions from photon energy, Schottky effect, and surface roughness are extracted. It is found the QE of a copper cathode illuminated by a 266 nm UV laser increased substantially to 1.5×10^{-4} after cathode cleaning during rf conditioning, and a copper work function of 4.16 eV, which is much lower than nominal value (4.65 eV, was measured. Experimental results also show a thermal emittance growth as much as 0.92  mm mrad/mm at 50  MV/m due to the cathode surface roughness effect, which is consistent with cathode surface morphology measurements.

  3. A basic study on lesion detectability for hot spot imaging of positron emitters with dedicated PET and positron coincidence gamma camera

    International Nuclear Information System (INIS)

    Zhang, Hong; Inoue, Tomio; Tian, Mei; Alyafei, Saleh; Oriuchi, Noboru; Khan, Nasim; Endo, Keigo; Li Sijin

    2001-01-01

    The aim of this study was to explore the correlations of detectability and the semi-quantification for hot spot imaging with positron emitters in positron emission tomography (PET) and with a positron coincidence detection system (PCD). Phantom study results for the measurement of the lesion-to-background (L/B) ratio ranged from 2.0 to 30.3, and detectability for hot spot lesion of PET and PCD were performed to correspond to clinical conditions. The detectability and semi-quantitative evaluation of hot spots from 4.4 mm to 36.9 mm in diameter were performed from the PET and PCD images. There were strong correlations between the L/B ratios derived from PET and PCD hot spot images and actual L/B ratios; but the L/B ratio derived from PET was higher than that from PCD with a significant difference of 10% to 54.8%. The detectability of hot spot imaging of PCD was lower than that of PET at 64.8% (PCD) versus 77.8% (PET). Even the actual L/B ratio was 8.0, hot spots more than 10.6 mm in diameter could be clearly identified with PCD imaging. The same identification could be achieved with PET imaging even when the actual L/B ratio was 4.0. This detailed investigation indicated that FDG PCD yielded results comparable to FDG PET on visual analysis and semi-quantitative analysis in detecting hot spots in phantoms, but semi-quantitative analysis of the L/B ratio with FDG PCD was inferior to that with FDG PET and the detectability of PCD in smaller hot spots was significantly poor. (author)

  4. Dense plasma focus PACO as a hard X-ray emitter: a study on the radiation source

    OpenAIRE

    Supán, L.; Guichón, S.; Milanese, Maria Magdalena; Niedbalski, Jorge Julio; Moroso, Roberto Luis; Acuña, H.; Malamud, Florencia

    2016-01-01

    The radiation in the X-ray range detected outside the vacuum chamber of the dense plasma focus (DPF) PACO, are produced on the anode zone. The zone of emission is studied in a shot-to-shot analysis, using pure deuterium as filling gas. We present a diagnostic method to determine the place and size of the hard X-ray source by image analysis of high density radiography plates. Fil: Supán, L.. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Insti...

  5. Low Emittance Guns for the ILC Polarized Electron Beam

    International Nuclear Information System (INIS)

    Clendenin, J. E.; Brachmann, A.; Ioakeimidi, K.; Kirby, R. E.; Maruyama, T.; Miller, R. H.; Wang, J. W.; Zhou, F.

    2007-01-01

    Polarized electron beams generated by DC guns are routinely available at several accelerators including JLAB, Mainz and SLAC. These guns operate with a cathode bias on the order of -100 kV. To minimize space charge effects, relatively long bunches are generated at the gun and then compressed longitudinally external to the gun just before and during initial acceleration. For linear colliders, this compression is accomplished using a combination of rf bunchers. For the basic design of the International Linear Collider (ILC), a 120 kV DC photocathode gun is used to produce a series of nanosecond bunches that are each compressed by two sub-harmonic bunchers (SHBs) followed by an L-band buncher and capture section. The longitudinal bunching process results in a significantly higher emittance than produced by the gun alone. While high-energy experiments using polarized beams are not generally sensitive to the source emittance, there are several benefits to a lower source emittance including a simpler more efficient injector system and a lower radiation load during transport especially at bends as at the damping ring. For the ILC, the SHBs could be eliminated if the voltage of the gun is raised sufficiently. Simulations using the General Particle Tracer (GPT) package indicate that a cathode bias voltage of ≥200 kV should allow both SHBs to be operated at 433 or even 650 MHz, while ≥500 kV would be required to eliminate the SHBs altogether. Simulations can be used to determine the minimum emittance possible if the injector is designed for a given increased voltage. A possible alternative to the DC gun is an rf gun. Emittance compensation, routinely used with rf guns, is discussed for higher-voltage DC guns

  6. Low Emittance Guns for the ILC Polarized Electron Beam

    International Nuclear Information System (INIS)

    Clendenin, J.E.; Brachmann, A.; Ioakeimidi, K.; Kirby, R.E.; Maruyama, T.; Miller, R.H.; Wang, J.W.; Zhou, F.; SLAC

    2006-01-01

    Polarized electron beams generated by DC guns are routinely available at several accelerators including JLAB, Mainz and SLAC. These guns operate with a cathode bias on the order of -100 kV. To minimize space charge effects, relatively long bunches are generated at the gun and then compressed longitudinally external to the gun just before and during initial acceleration. For linear colliders, this compression is accomplished using a combination of rf bunchers. For the basic design of the International Linear Collider (ILC), a 120 kV DC photocathode gun is used to produce a series of nanosecond bunches that are each compressed by two sub-harmonic bunchers (SHBs) followed by an L-band buncher and capture section. The longitudinal bunching process results in a significantly higher emittance than produced by the gun alone. While high-energy experiments using polarized beams are not generally sensitive to the source emittance, there are several benefits to a lower source emittance including a simpler more efficient injector system and a lower radiation load during transport especially at bends as at the damping ring. For the ILC, the SHBs could be eliminated if the voltage of the gun is raised sufficiently. Simulations using the General Particle Tracer (GPT) package indicate that a cathode bias voltage of (ge)200 kV should allow both SHBs to be operated at 433 or even 650 MHz, while (ge)500 kV would be required to eliminate the SHBs altogether. Simulations can be used to determine the minimum emittance possible if the injector is designed for a given increased voltage. A possible alternative to the DC gun is an rf gun. Emittance compensation, routinely used with rf guns, is discussed for higher-voltage DC guns

  7. Comparative studies of natural and artificial α-emitters (actinides) in the lichen-reindeer-man food chain

    International Nuclear Information System (INIS)

    Holm, E.; Persson, B.R.R.

    1981-01-01

    Fallout of actinide elements has been investigated by studying samples of lichen collected at different places in Scandinavia. Maximum-activity concentrations of plutonium isotopes in lichen were found in 1965. Americium-241 has been formed in situ from the decay of 241 Pu, and the maximum-activity concentration found in lichen is 35 PCi/kg. In reindeer, the activity concentrations of 239+240 Pu, 241 Pu, and 241 Am have been studied in liver and bone. The fraction of Pu activity ingested and retained in reindeer liver is about two to three times higher than that of Am. Investigations of Pu and Am in human food chains raise the question of comparisons with the natural α-emitting radionuclides uranium, thorium, and their daughters. Americium and thorium exhibit very similar biophysical behavior in the environement. The fraction of activity that is absorbed by gastrointestinal ingestion seems to be of the same order of magnitude. High concentrations of uranium in reindeer tissues probably depend on a high intake from drinking water and other foodstuffs than lichen

  8. Skew quad compensation for SPEAR minibeta optics

    International Nuclear Information System (INIS)

    Wille, K.

    1984-06-01

    With the new minibeta insertion for SPEAR the betatron coupling and the perturbations of beam optics caused by the solenoid field of the MARK III detector can't be compensated by the simple coils used so far. Therefore another scheme with four skew quads arranged in two families has been chosen. Even though this scheme doesn't compensate the effect of the solenoid on the beam completely, the residual emittance coupling is much less than 1% which should be sufficient under all running conditions. The major advantage of this concept is its simplicity

  9. Low emittance configuration for spear

    International Nuclear Information System (INIS)

    Blumberg, L.N.; Harris, J.; Stege, R.; Cerino, J.; Hettel, R.; Hofmann, A.; Liu, R.Z.; Wiedemann, H.; Winick, H.

    1985-01-01

    The quality of synchrotron radiation beams from SPEAR, in particular the brilliance of undulator radiation, can be improved significantly by reducing the emittance of the stored electron beam. A reduction of the horizontal emittance by a factor of 3.5 to a value of 130 nanometer-radians (nm-r) at 3 GeV has been achieved by using stronger focussing, mainly in the horizontal plane. The low emittance configuration also reduces the dispersion and vertical beta functions in the straight sections, making them more suitable for wigglers. The higher betatron tunes lead to a larger phase advance between the two kickers, which has to be corrected during injection by shunting current from some quadrupoles. The configuration was optimized within SPEAR hardware limitations and tested for dynamic aperture with the tracking program PATRICIA. After implementation of this scheme, beam was successfully injected and accumulated. The measured emittance of the stored beam was in agreement with calculations. Presently the configuration is being made operational

  10. Measuring emittances and sigma matrices

    International Nuclear Information System (INIS)

    Rees, J.; Rivkin, L.

    1984-03-01

    The method used for measuring emittance at the SLAC Linac and the linear collider damping ring is described. The basis of the method is derived using one two-by-two matrix to specify the state of the input beam (sigma matrix) and another to describe the lens-drift transport system (R-matrix)

  11. Development of prediction models of stress and long-term disability among claimants to injury compensation systems: a cohort study.

    Science.gov (United States)

    Spittal, Matthew J; Grant, Genevieve; O'Donnell, Meaghan; McFarlane, Alexander C; Studdert, David M

    2018-04-28

    We sought to develop prognostic risk scores for compensation-related stress and long-term disability using markers collected within 3 months of a serious injury. Cohort study. Predictors were collected at baseline and at 3 months postinjury. Outcome data were collected at 72 months postinjury. Hospitalised patients with serious injuries recruited from four major trauma hospitals in Australia. 332 participants who made claims for compensation for their injuries to a transport accident scheme or a workers' compensation scheme. 12-item WHO Disability Assessment Schedule and 6 items from the Claims Experience Survey. Our model for long-term disability had four predictors (unemployed at the time of injury, history of a psychiatric disorder at time of injury, post-traumatic stress disorder symptom severity at 3 months and disability at 3 months). This model had good discrimination (R 2 =0.37) and calibration. The disability risk score had a score range of 0-180, and at a threshold of 80 had sensitivity of 56% and specificity of 86%. Our model for compensation-related stress had five predictors (intensive care unit admission, discharged to home, number of traumatic events prior to injury, depression at 3 months and not working at 3 months). This model also had good discrimination (area under the curve=0.83) and calibration. The compensation-related stress risk score had score range of 0-220 and at a threshold of 100 had sensitivity of 74% and specificity of 75%. By combining these two scoring systems, we were able to identify the subgroup of claimants at highest risk of experiencing both outcomes. The ability to identify at an early stage claimants at high risk of compensation-related stress and poor recovery is potentially valuable for claimants and the compensation agencies that serve them. The scoring systems we developed could be incorporated into the claims-handling processes to guide prevention-oriented interventions. © Article author(s) (or their employer

  12. Gender Bias in Compensation Structures: A Case Study of Its Historical Basis and Persistence.

    Science.gov (United States)

    Kim, Marlene

    1989-01-01

    Discusses ways in which historical wage structures still influence current salaries and underpay for female-dominated jobs. Examines the origins of the California State Civil Service's compensation structure, and finds that gender discrimination explicitly lowered wages for female-dominated jobs. Provides quantitative and qualitative evidence of…

  13. An explorative study into changes in reach performance after gravity compensation training in chronic stroke patients

    NARCIS (Netherlands)

    Prange, Grada Berendina; Krabben, T.; Renzenbrink, G.J.; de Boer, Jan; Hermens, Hermanus J.; Jannink, M.J.A.

    2009-01-01

    After stroke, arm function can be limited by a reduction in the selectivity of movements, due to involuntary coupling of shoulder abduction and elbow flexion, limiting the ability to reach. Gravity compensation reduces the required active shoulder abduction torques, which results in a larger range

  14. Electromagnetic compatibility of implantable neurostimulators to RFID emitters.

    Science.gov (United States)

    Pantchenko, Oxana S; Seidman, Seth J; Guag, Joshua W; Witters, Donald M; Sponberg, Curt L

    2011-06-09

    The objective of this study is to investigate electromagnetic compatibility (EMC) of implantable neurostimulators with the emissions from radio frequency identification (RFID) emitters. Six active implantable neurostimulators with lead systems were tested for susceptibility to electromagnetic fields generated by 22 RFID emitters. These medical devices have been approved for marketing in the U.S. for a number of intended uses that include: epilepsy, depression, incontinence, Parkinsonian tremor and pain relief. Each RFID emitter had one of the following carrier frequencies: 125 kHz, 134 kHz, 13.56 MHz, 433 MHz, 915 MHz and 2.45 GHz. The test results showed the output of one of the implantable neurostimulators was inhibited by 134 kHz RFID emitter at separation distances of 10 cm or less. The output of the same implantable neurostimulator was also inhibited by another 134 kHz RFID emitter at separation distances of 10 cm or less and also showed inconsistent pulsing rate at a separation distance of 15 cm. Both effects occurred during and lasted through out the duration of the exposure. The clinical significance of the effects was assessed by a clinician at the U.S. Food and Drug Administration. The effects were determined to be clinically significant only if they occurred for extended period of time. There were no observed effects from the other 5 implantable neurostimulators or during exposures from other RFID emitters.

  15. Electromagnetic compatibility of implantable neurostimulators to RFID emitters

    Directory of Open Access Journals (Sweden)

    Guag Joshua W

    2011-06-01

    Full Text Available Abstract Background The objective of this study is to investigate electromagnetic compatibility (EMC of implantable neurostimulators with the emissions from radio frequency identification (RFID emitters. Methods Six active implantable neurostimulators with lead systems were tested for susceptibility to electromagnetic fields generated by 22 RFID emitters. These medical devices have been approved for marketing in the U.S. for a number of intended uses that include: epilepsy, depression, incontinence, Parkinsonian tremor and pain relief. Each RFID emitter had one of the following carrier frequencies: 125 kHz, 134 kHz, 13.56 MHz, 433 MHz, 915 MHz and 2.45 GHz Results The test results showed the output of one of the implantable neurostimulators was inhibited by 134 kHz RFID emitter at separation distances of 10 cm or less. The output of the same implantable neurostimulator was also inhibited by another 134 kHz RFID emitter at separation distances of 10 cm or less and also showed inconsistent pulsing rate at a separation distance of 15 cm. Both effects occurred during and lasted through out the duration of the exposure. Conclusions The clinical significance of the effects was assessed by a clinician at the U.S. Food and Drug Administration. The effects were determined to be clinically significant only if they occurred for extended period of time. There were no observed effects from the other 5 implantable neurostimulators or during exposures from other RFID emitters.

  16. Measured emittance dependence on injection method in laser plasma accelerators

    Science.gov (United States)

    Barber, Samuel; van Tilborg, Jeroen; Schroeder, Carl; Lehe, Remi; Tsai, Hai-En; Swanson, Kelly; Steinke, Sven; Nakamura, Kei; Geddes, Cameron; Benedetti, Carlo; Esarey, Eric; Leemans, Wim

    2017-10-01

    The success of many laser plasma accelerator (LPA) based applications relies on the ability to produce electron beams with excellent 6D brightness, where brightness is defined as the ratio of charge to the product of the three normalized emittances. As such, parametric studies of the emittance of LPA generated electron beams are essential. Profiting from a stable and tunable LPA setup, combined with a carefully designed single-shot transverse emittance diagnostic, we present a direct comparison of charge dependent emittance measurements of electron beams generated by two different injection mechanisms: ionization injection and shock induced density down-ramp injection. Notably, the measurements reveal that ionization injection results in significantly higher emittance. With the down-ramp injection configuration, emittances less than 1 micron at spectral charge densities up to 2 pC/MeV were measured. This work was supported by the U.S. DOE under Contract No. DE-AC02-05CH11231, by the NSF under Grant No. PHY-1415596, by the U.S. DOE NNSA, DNN R&D (NA22), and by the Gordon and Betty Moore Foundation under Grant ID GBMF4898.

  17. Photoacoustic and dielectric spectroscopic studies of 4-dimethylamino-n-methyl-4-stilbazolium tosylate single crystal: An efficient terahertz emitter

    Science.gov (United States)

    Manivannan, M.; Martin Britto Dhas, S. A.; Jose, M.

    2016-12-01

    Bulk terahertz emitting single crystal of 4-dimethylamino-N-methyl-4-stilbazolium tosylate (DAST) was synthesized by condensation method and grown by slow solvent evaporation technique from methanol. The structure and cell parameters of the grown crystals were derived from single crystal and powder X-ray diffraction analyses and the optical properties of the crystal were analyzed by UV-Vis Spectrophotometer. The presence of functional groups was identified by FTIR and FT-Raman spectroscopic studies. We demonstrated that in DAST crystal, the thermal transport properties such as thermal conductivity, thermal diffusivity and thermal effusivity are better than several well recognized standard materials using photoacoustic spectrophotometer. The dielectric measurement was made as a function of frequency (1 Hz-35 MHz) at different temperatures (30-200 °C). The dielectric constant and dielectric loss were found to be strongly dependent on temperature and frequency of the applied electric field. The semicircle in the cole-cole plot showed the presence of dielectric relaxation in the crystal with its diameter representing the resistance of the crystal. The resistivity and ac conductivity were calculated from the measured dielectric data.

  18. Long-term follow-up of whiplash injuries reported to insurance companies: a cohort study on patient-reported outcomes and impact of financial compensation.

    Science.gov (United States)

    Rydman, Eric; Ponzer, Sari; Brisson, Rosa; Ottosson, Carin; Pettersson-Järnbert, Hans

    2018-02-10

    The long-term outcome of Whiplash-associated disorder (WADs) has been reported to be poor in populations from medical settings. However, no trials have investigated the long-term prognosis of patients from medico-legal environment. For this group, the "compensation hypothesis" suggests financial compensation being associated with worsened outcome. The aims of this study were to describe long-term (2-4 years) non-recovery rates in participants with WAD recruited from insurance companies and to investigate the association between self-reported non-recovery and financial compensation. 144 participants, reporting neck pain after a motor vehicle accident, were recruited from two major insurance companies in Sweden. Self-reported recovery was measured at 6 months and 2-4 years. Those who received financial compensation from an insurance company were compared with those who received no compensation. The overall non-recovery rate after 2-4 years was 55.9% (66/118). In the non-compensated group, the non-recovery rate was 51.0% (25/49) and in the compensated group 73% (27/37) (p = 0.039). Adjusted OR was 4.33 (1.37-13.66). High level of pain at baseline was a strong predictor of non-recovery [OR 46 (4.7-446.0)]. However, no association was found between pain level at baseline and financial compensation. The non-recovery rate among patients making insurance claims is high, especially among those receiving financial compensation even if causal relationship cannot be determined based on this study. However, lack of association between baseline level of pain and compensation supports the compensation hypothesis.

  19. Optical design and studies of a tiled single grating pulse compressor for enhanced parametric space and compensation of tiling errors

    Science.gov (United States)

    Daiya, D.; Patidar, R. K.; Sharma, J.; Joshi, A. S.; Naik, P. A.; Gupta, P. D.

    2017-04-01

    A new optical design of tiled single grating pulse compressor has been proposed, set-up and studied. The parametric space, i.e. the laser beam diameters that can be accommodated in the pulse compressor for the given range of compression lengths, has been calculated and shown to have up to two fold enhancement in comparison to our earlier proposed optical designs. The new optical design of the tiled single grating pulse compressor has an additional advantage of self compensation of various tiling errors like longitudinal and lateral piston, tip and groove density mismatch, compared to the earlier designs. Experiments have been carried out for temporal compression of 650 ps positively chirped laser pulses, at central wavelength 1054 nm, down to 235 fs in the tiled grating pulse compressor set up with the proposed design. Further, far field studies have been performed to show the desired compensation of the tiling errors takes place in the new compressor.

  20. Long-range and head-on beam-beam compensation studies in RHIC with lessons for the LHC

    International Nuclear Information System (INIS)

    Fischer, W.; Luo, Y.; Abreu, N.; Calaga, R.; Montag, C.; Robert-Demolaize, G.; Dorda, U.; Koutchouk, J.-P.; Sterbini, G.; Zimmermann, F.; Kim, H.-J.; Sen, T.; Shiltsev, V.; Valishev, A.; Qiang, J.; Kabel, A.

    2009-01-01

    Long-range as well as head-on beam-beam effects are expected to limit the LHC performance with design parameters. They are also important consideration for the LHC upgrades. To mitigate long-range effects, current carrying wires parallel to the beam were proposed. Two such wires are installed in RHIC where they allow studying the effect of strong long-range beam-beam effects, as well as the compensation of a single long-range interaction. The tests provide benchmark data for simulations and analytical treatments. Electron lenses were proposed for both RHIC and the LHC to reduce the head-on beam-beam effect. We present the experimental long-range beam-beam program at RHIC and report on head-on compensations studies based on simulations

  1. Monte-Carlo study of electron noise in compensated InSb

    International Nuclear Information System (INIS)

    Ašmontas, S; Raguotis, R; Bumelienė, S

    2015-01-01

    The results of Monte Carlo simulations of the electron noise in lightly doped and strongly compensated n-type InSb are presented. The strong electron scattering by ionized impurities is established to change essentially the electron distribution function, spectral density of velocity fluctuations and the dependence of noise temperature on the electric field strength. It is found that the electron noise temperature in strongly compensated InSb with low electron density at liquid nitrogen temperature is close to the lattice temperature in a wide range of electric field strength in which the electron gas cooling effect takes place. The increase of electron density is shown to weaken the electron gas cooling effect due to more intensive electron–electron collisions stimulating delocalization of electrons from the bottom of the conduction band. A satisfactory agreement between calculations and available experimental data is obtained. (paper)

  2. Calculations of emittance and damping time effects in the SLC damping rings

    International Nuclear Information System (INIS)

    Limberg, T.; Moshammer, H.; Raubenheimer, T.; Spencer, J.; Siemann, R.

    1992-03-01

    In a recent NDR machine experiment the transverse emittance was studied as a function of store time and tune. To explain the observed transverse emittance damping time constants, the magnetic measurement data of the longitudinal field of the bending magnets had to be taken into account. The variation of the transverse emittances with tune due to misalignments and the associated anomalous dispersion is studied as well as the effect of synchrobetatron coupling due to dispersion in the RF cavities

  3. Sources of Emittance in RF Photocathode Injectors

    Energy Technology Data Exchange (ETDEWEB)

    Dowell, David [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2016-12-11

    Advances in electron beam technology have been central to creating the current generation of x-ray free electron lasers and ultra-fast electron microscopes. These once exotic devices have become essential tools for basic research and applied science. One important beam technology for both is the electron source which, for many of these instruments, is the photocathode RF gun. The invention of the photocathode gun and the concepts of emittance compensation and beam matching in the presence of space charge and RF forces have made these high-quality beams possible. Achieving even brighter beams requires a taking a finer resolution view of the electron dynamics near the cathode during photoemission and the initial acceleration of the beam. In addition, the high brightness beam is more sensitive to degradation by the optical aberrations of the gun’s RF and magnetic lenses. This paper discusses these topics including the beam properties due to fundamental photoemission physics, space charge effects close to the cathode, and optical distortions introduced by the RF and solenoid fields. Analytic relations for these phenomena are derived and compared with numerical simulations.

  4. Whiplash and the compensation hypothesis.

    Science.gov (United States)

    Spearing, Natalie M; Connelly, Luke B

    2011-12-01

    Review article. To explain why the evidence that compensation-related factors lead to worse health outcomes is not compelling, either in general, or in the specific case of whiplash. There is a common view that compensation-related factors lead to worse health outcomes ("the compensation hypothesis"), despite the presence of important, and unresolved sources of bias. The empirical evidence on this question has ramifications for the design of compensation schemes. Using studies on whiplash, this article outlines the methodological problems that impede attempts to confirm or refute the compensation hypothesis. Compensation studies are prone to measurement bias, reverse causation bias, and selection bias. Errors in measurement are largely due to the latent nature of whiplash injuries and health itself, a lack of clarity over the unit of measurement (specific factors, or "compensation"), and a lack of appreciation for the heterogeneous qualities of compensation-related factors and schemes. There has been a failure to acknowledge and empirically address reverse causation bias, or the likelihood that poor health influences the decision to pursue compensation: it is unclear if compensation is a cause or a consequence of poor health, or both. Finally, unresolved selection bias (and hence, confounding) is evident in longitudinal studies and natural experiments. In both cases, between-group differences have not been addressed convincingly. The nature of the relationship between compensation-related factors and health is unclear. Current approaches to testing the compensation hypothesis are prone to several important sources of bias, which compromise the validity of their results. Methods that explicitly test the hypothesis and establish whether or not a causal relationship exists between compensation factors and prolonged whiplash symptoms are needed in future studies.

  5. Research on Value Assessment and Compensation for Health Hazards of Urban Air Pollution-A Case Study of Urumqi

    Directory of Open Access Journals (Sweden)

    Chen Yu

    Full Text Available ABSTRACT With the acceleration of urbanization and industrialization, urban air pollution has become a serious threat to the health of urban residents. In this study, to investigate health hazards caused by air pollution for urban residents, concentrations of main air pollutants and annual coal consumption amounts during the period from 2000 to 2013 were analyzed. Our results showed that economic losses of Urumqi caused by air pollution amounted to 63.155 million yuan in 2013, accounting for 0.2 ‰ of its GDP and 5.7% of public utility expenditures for that year. The compensation mechanism analysis suggested that it is necessary to further improve the health care system and increase corporate environmental taxes. More environmental health protection taxes should be levied on key monitoredenterprises in Urumqi to achieve effective compensations for urban residents affected by air pollution-related health hazards.

  6. Family members' involvement in elder care provision in nursing homes and their considerations about financial compensation: a qualitative study.

    Science.gov (United States)

    Habjanič, Ana; Pajnkihar, Majda

    2013-01-01

    The aim of this study was to establish how family members are involved in elder care provision in nursing homes; this included research into their feelings about potentially extending their involvement to obtain financial benefits as compensation for high accommodation costs. Family members remain involved in the caring process after their relatives have been admitted to an institution. On average, accommodation costs in nursing homes in Slovenia have risen above the residents' retirement pension, and families must supplement the difference. Because of this, familial involvement should be linked to reduced accommodation costs. This research employed a non-experimental, descriptive study design through unstructured interviews. Participants included fifty family members (n=50) who visit their relatives in nursing homes. Data were collected in 2010 at five nursing homes in Slovenia and processed by means of conventional content analysis. The major themes that emerged from the content analysis, describing family involvement, were as follows: visiting and making oneself useful, delivery of items for personal use, hands-on care, physical therapy and organization of nursing home activities. Family members showed some interest in receiving financial compensation for their involvement. The proposed financial compensation may be a delicate and morally questionable matter but would involve fairness and transparency, while enabling easier organization of elder care provision. Eventually, nursing home residents' well-being could be improved. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  7. Inequities in Academic Compensation by Gender: A Follow-up to the National Faculty Survey Cohort Study.

    Science.gov (United States)

    Freund, Karen M; Raj, Anita; Kaplan, Samantha E; Terrin, Norma; Breeze, Janis L; Urech, Tracy H; Carr, Phyllis L

    2016-08-01

    Cross-sectional studies have demonstrated gender differences in salaries within academic medicine. No research has assessed longitudinal compensation patterns. This study sought to assess longitudinal patterns by gender in compensation, and to understand factors associated with these differences in a longitudinal cohort. A 17-year longitudinal follow-up of the National Faculty Survey was conducted with a random sample of faculty from 24 U.S. medical schools. Participants employed full-time at initial and follow-up time periods completed the survey. Annual pretax compensation during academic year 2012-2013 was compared by gender. Covariates assessed included race/ethnicity; years since first academic appointment; retention in academic career; academic rank; departmental affiliation; percent effort distribution across clinical, teaching, administrative, and research duties; marital and parental status; and any leave or part-time status in the years between surveys. In unadjusted analyses, women earned a mean of $20,520 less than men (P = .03); women made 90 cents for every dollar earned by their male counterparts. This difference was reduced to $16,982 (P = .04) after adjusting for covariates. The mean difference of $15,159 was no longer significant (P = .06) when adjusting covariates and for those who had ever taken a leave or worked part-time. The continued gender gap in compensation cannot be accounted for by metrics used to calculate salary. Institutional actions to address these disparities include both initial appointment and annual salary equity reviews, training of senior faculty and administrators to understand implicit bias, and training of women faculty in negotiating skills.

  8. The opinion of Turkish cardiologists on current malpractice system and an alternative patient compensation system proposal: PCS study group.

    Science.gov (United States)

    Olcay, Ayhan; Emren, Sadık Volkan; Babür Güler, Gamze; Güler, Ekrem; Ertunç, Vedat; Berilgen, Rida; Aslan, Abdullah; Şimşek, Ersin Çağrı; Gölcük, Şükriye Ebru; Yalın, Kıvanç

    2017-10-01

    Cardiologists participate in the diagnosis and interventional treatment of numerous high-risk patients. The goal of this study was to investigate how the current malpractice system in Turkey influences cardiologists' diagnostic and interventional behavior and to obtain their opinions about an alternative patient compensation system. The present cross-sectional study assessed the practice of defensive medicine among cardiologists who are actively working in various types of workplace within the Turkish healthcare system. A 24-item questionnaire was distributed to cardiology residents, specialists, and academics in Turkey in print format, by electronic mail, or via cell phone message. A total of 253 cardiologists responded to the survey. Among them, 29 (11.6%) had been sued for malpractice claims in the past. Of the cardiologists who had been sued, 2 (6.9%) had been ordered to pay financial compensation, and 1 (3.4%) was given a sentence of imprisonment due to negligence. In all, 132 (52.8%) of the surveyed cardiologists reported that they had changed their practices due to fear of litigation, and 232 (92.8%) reported that they would prefer the new proposed patient compensation system to the current malpractice system. Among the cardiologists surveyed, 78.8% indicated that malpractice fear had affected their decision-making with regard to requesting computed tomography angiography or thallium scintigraphy, 71.6% for coronary angiography, 20% for stent implantation, and 83.2% for avoiding treating high-risk patients. The results of this survey demonstrated that cardiologists may request unnecessary tests and perform unneeded interventions due to the fear of malpractice litigation fear. Many also avoid high-risk patients and interventions. The majority indicated that they would prefer the proposed alternative patient compensation system to the current malpractice system.

  9. Narratives of Compensated Dating of Girls in Hong Kong Using Routine Activity Theory: Results of a Focus Group Study of Guardians.

    Science.gov (United States)

    Li, Jessica C M; Cheung, Chau-Kiu; Jia, Cindy X S; Yu, Yolanda M Y; Nguyen, Ping

    2018-02-01

    This article presents public discourses on compensated dating of adolescent girls in Chinese society. Data are obtained from eight focus groups comprising 50 guardians at private, parochial, and public levels (i.e., social workers, police officers, parents of students, and community representatives). Qualitative data are used to demonstrate how the guardians conceptualize and contextualize compensated dating as an outcome of the dynamics of societal features. Social features such as contemporary ideologies, Internet technology advancement, commercialization of human relationships, and ambiguity between "right" and "wrong" motivate the service providers and customers of compensated dating, and accelerate their convergence and weakened levels of guardianship in society. This study is the first to connect the features of compensated dating of adolescent girls with recent societal changes using the routine activity approach. The findings confirm the application of the routine activity approach in the phenomenon of girls' compensated dating, and also offer theoretical and practical implications.

  10. Compensator design for corrector magnet power supply of TPS facility

    International Nuclear Information System (INIS)

    Wong, Y.-S.; Chen, J.-F.; Liu, K.-B.; Liu, C.-Y.; Wang, B.-S.

    2017-01-01

    From 2012 to 2015, Taiwan government has a most important technology project is Taiwan Photon Source (TPS), the total budget of TPS fund to over US300 million. It set up a synchrotron storage ring (electron energy of 3.3 GeV, circumference of 518 m, and low emittance) that provides one of the world's brightest synchrotron sources of x-rays. This study presents a compensator design for corrector magnet power supply to avoid limitations in stabilizing the frequency when the machine output current load is valid. A lead-lag compensator had been built in a full-bridge converter to improve the system bandwidth. Lead-lag compensators influence various disciplines, such as robotics, satellite control, automobile diagnostics, and laser frequency stabilization. These components are important building blocks in analog control systems and can also be used in digital control. A 50V output voltage and 10A output current prototype converter is fabricated in the laboratory. From the experimental results, the effectiveness of the control loop design can be verified from the gain margin and phase margin.

  11. Compensator design for corrector magnet power supply of TPS facility

    Science.gov (United States)

    Wong, Y.-S.; Chen, J.-F.; Liu, K.-B.; Liu, C.-Y.; Wang, B.-S.

    2017-10-01

    From 2012 to 2015, Taiwan government has a most important technology project is Taiwan Photon Source (TPS), the total budget of TPS fund to over US300 million. It set up a synchrotron storage ring (electron energy of 3.3 GeV, circumference of 518 m, and low emittance) that provides one of the world's brightest synchrotron sources of x-rays. This study presents a compensator design for corrector magnet power supply to avoid limitations in stabilizing the frequency when the machine output current load is valid. A lead-lag compensator had been built in a full-bridge converter to improve the system bandwidth. Lead-lag compensators influence various disciplines, such as robotics, satellite control, automobile diagnostics, and laser frequency stabilization. These components are important building blocks in analog control systems and can also be used in digital control. A 50V output voltage and 10A output current prototype converter is fabricated in the laboratory. From the experimental results, the effectiveness of the control loop design can be verified from the gain margin and phase margin.

  12. Characteristics of and risk factors for compensated occupational injury and disease claims in dairy farmers: a case-control study.

    Science.gov (United States)

    Karttunen, J P; Rautiainen, R H

    2013-07-01

    Research indicates that dairy farmers have an elevated risk of work-related adverse health outcomes. This case-control study evaluated the characteristics of and risk factors for compensated occupational injury and disease claims among Finnish dairy farmers. The cases consisted of 19 farm couples in which both spouses had a history of multiple claims. There were 283 claims in total, a rate of 26.6 claims per 100 person-years. The controls consisted of 12 couples in which neither spouse had compensated or rejected claims during their work history as insured farmers. A combined mail/telephone survey charted potential risk factors for compensated claims. These claims frequently involved work tasks and causes related to animal husbandry. Cattle were the most common cause for injuries in general and for serious injuries in particular. Gender differences in farm work and claims were observed. Using logistic regression analyses, we identified personal and work-related risk factors including long work history, small-scale dairy farm operation, and conventional stanchion barn for dairy cattle. Outdated working conditions, while not statistically significant, were positively associated with claims as well. Declined current work ability and musculoskeletal or respiratory conditions were significantly associated with claims where each of these outcomes may contribute to the other. Identified factors could be used to select subgroups of dairy farmers with either elevated or reduced risk of claims. Prevention of adverse health outcomes could be most effective when targeted to farmers at highest risk of occupational injury and disease.

  13. Study on offshore wind farm integration mode and reactive power compensation

    Energy Technology Data Exchange (ETDEWEB)

    Bian, Xiaoyan; Hong, Lijun; Fu, Yang [Shanghai Univ. of Electrical Power (China). Power and Automation Engineering Dept.

    2013-07-01

    Two typical offshore wind farm grid-connected modes are introduced and dynamic characteristics under their modes are compared from the simulation by PSS/E. The result shows that offshore wind farm with VSC-HVDC has better dynamic characteristics on fault isolation, reactive power compensation, and fault ride through ability. In addition, STATCOM has been applied to the offshore wind farm, the simulation results indicates that it can improve the bus voltage stability in fault and maintain the voltage level under a small perturbation.

  14. Dielectric optical antenna thermal emitters and metamaterials

    Science.gov (United States)

    Schuller, Jonathan Aaron

    Optical antennas are critical components in nanophotonics research due to their unparalleled ability to concentrate electromagnetic energy into nanoscale volumes. Researchers typically construct such antennas from wavelength-size metallic structures. However, recent research has begun to exploit the scattering resonances of high-permittivity particles to realize all-dielectric optical antennas, emitters, and metamaterials. In this thesis, we experimentally and theoretically characterize the resonant modes of subwavelength rod-shaped dielectric particles and demonstrate their use in negative index metamaterials and novel infrared light emitters. At mid-infrared frequencies, Silicon Carbide (SiC) is an ideal system for studying the behavior of dielectric optical antennas. At frequencies below the TO phonon resonance, SiC behaves like a dielectric with very large refractive index. Using infrared spectroscopy and analytical Mie calculations we show that individual rod-shaped SiC particles exhibit a multitude of resonant modes. Detailed investigations of these SiC optical antennas reveal a wealth of new physics and applications. We discuss the distinct electromagnetic field profile for each mode, and demonstrate that two of the dielectric-type Mie resonances can be combined in a particle array to form a negative index metamaterial. We further show that these particles can serve as "broadcasting" antennas. Using a custom-built thermal emission microscope we collect emissivity spectra from single SiC particles at elevated temperatures, highlighting their use as subwavelength resonant light emitters. Finally, we derive and verify a variety of general analytical results applicable to all cylindrical dielectric antennas.

  15. Dielectric Optical Antenna Emitters and Metamaterials

    Science.gov (United States)

    Schuller, Jon

    2009-03-01

    Optical antennas are critical components in nanophotonics research due to their unparalleled ability to concentrate electromagnetic energy into nanoscale volumes. Researchers typically construct such antennas from wavelength-size metallic structures. However, recent research has begun to exploit the scattering resonances of high-permittivity particles to realize all-dielectric optical antennas, emitters, and metamaterials. In this talk, we experimentally and theoretically characterize the resonant modes of subwavelength rod-shaped dielectric particles and demonstrate their use in negative index metamaterials and novel infrared light emitters. At mid-infrared frequencies, Silicon Carbide (SiC) is an ideal system for studying the behavior of dielectric optical antennas. At frequencies below the TO phonon resonance, SiC behaves like a dielectric with very large refractive index. Using infrared spectroscopy and analytical Mie calculations we show that individual rod-shaped SiC particles exhibit a multitude of resonant modes. Detailed investigations of these SiC optical antennas reveal a wealth of new physics and applications. We discuss the distinct electromagnetic field profile for each mode, and demonstrate that two of the dielectric-type Mie resonances can be combined in a particle array to form a negative index metamaterial [1]. We further show that these particles can serve as ``broadcasting'' antennas. Using a custom-built thermal emission microscope we collect emissivity spectra from single SiC particles at elevated temperatures, highlighting their use as subwavelength resonant light emitters. Finally, we derive and verify a variety of general analytical results applicable to all cylindrical dielectric antennas and discuss extensions of the demonstrated concepts to different materials systems and frequency regimes. [1] J.A. Schuller, et al., Phys. Rev. Lett. 99, 107401 (2007)

  16. Multibunch emittance growth and its corrections in S-Band linear collider

    International Nuclear Information System (INIS)

    Gao, J.

    1994-11-01

    Multibunch emittance growths caused by long range wake fields with the misalignments of accelerating structures and quadrupoles in S-Band linear collider are studied. Tolerances for the misalignment errors of accelerating structures and quadrupoles are given corresponding to different detuned+damped structures. At the end of main linac, emittance corrector (EC) is proposed to be used to reduce further the multibunch emittance. Numerical simulations show that the effect of EC is obvious (multibunch emittance can be reduced about one order of magnitude), and it is believed that this kind of EC will be necessary for future linear colliders. (author). 16 refs., 21 figs., 4 tabs

  17. Very low recombination phosphorus emitters for high efficiency crystalline silicon solar cells

    International Nuclear Information System (INIS)

    Ortega, P; Vetter, M; Bermejo, S; Alcubilla, R

    2008-01-01

    This work studies low recombination phosphorus emitters on c-Si. The emitters are fabricated by diffusion from solid sources and then passivated by thermal oxide yielding sheet resistances between 15 and 280 Ω/sq. Emitter saturation current densities lie in the 2.5–110 fA cm −2 range, leading to implicit open-circuit voltages between 674 and 725 mV. Bulk lifetime is limited by intrinsic recombination mechanisms. Surface recombination velocities between 80 and 300 cm s −1 have been obtained, appearing among the lowest reported in this range of emitter sheet resistances

  18. Emittance Measurements from a Laser Driven Electron Injector

    Energy Technology Data Exchange (ETDEWEB)

    Reis, David A

    2003-07-28

    The Gun Test Facility (GTF) at the Stanford Linear Accelerator Center was constructed to develop an appropriate electron beam suitable for driving a short wavelength free electron laser (FEL) such as the proposed Linac Coherent Light Source (LCLS). For operation at a wavelength of 1.5 {angstrom}, the LCLS requires an electron injector that can produce an electron beam with approximately 1 {pi} mm-mrad normalized rms emittance with at least 1 nC of charge in a 10 ps or shorter bunch. The GTF consists of a photocathode rf gun, emittance-compensation solenoid, 3 m linear accelerator (linac), drive laser, and diagnostics to measure the beam. The rf gun is a symmetrized 1.6 cell, s-band high gradient, room temperature, photocathode structure. Simulations show that this gun when driven by a temporally and spatially shaped drive laser, appropriately focused with the solenoid, and further accelerated in linac can produce a beam that meets the LCLS requirements. This thesis describes the initial characterization of the laser and electron beam at the GTF. A convolved measurement of the relative timing between the laser and the rf phase in the gun shows that the jitter is less than 2.5 ps rms. Emittance measurements of the electron beam at 35 MeV are reported as a function of the (Gaussian) pulse length and transverse profile of the laser as well as the charge of the electron beam at constant phase and gradient in both the gun and linac. At 1 nC the emittance was found to be {approx} 13 {pi} mm-mrad for 5 ps and 8 ps long laser pulses. At 0.5 nC the measured emittance decreased approximately 20% in the 5 ps case and 40% in the 8 ps case. These measurements are between 40-80% higher than simulations for similar experimental conditions. In addition, the thermal emittance of the electron beam was measured to be 0.5 {pi} mm-mrad.

  19. Transverse emittance measurement and preservation at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Maria

    2016-06-20

    The Large Hadron Collider (LHC) at CERN is a high energy storage ring that provides proton and heavy ion collisions to study fundamental particle physics. The luminosity production is closely linked to emittance preservation in the accelerator. The transverse emittance is the phase space density of the beam and should be conserved when the particle beam is transformed through the accelerator. Perturbing effects, however, can lead to emittance increase and hence luminosity degradation. Measuring the emittance growth is a complex task with high intensity beams and changing energies. The machine optics and the transverse beam size have to be measured as accurately as possible. Beta function measurements with k-modulation are discussed. With this method the quadrupole focussing strength is varied and the resulting tune change is traced to determine the beta function at the quadrupole. A new k-modulation measurement tool was developed for the LHC. The fully automatic and online measurement system takes constraints of various systems such as tune measurement precision and powering limitations of the LHC superconducting circuits into account. With sinusoidal k-modulation record low beta function measurement uncertainties in the LHC have been reached. 2015 LHC beta function and β*, which is the beta function at the collision point, measurements with k-modulation will be presented. Wire scanners and synchrotron light monitors are presently used in the LHC to measure the transverse beam size. Accuracy and limitations of the LHC transverse profile monitors are discussed. During the 2012 LHC proton run it was found that wire scanner photomultiplier saturation added significant uncertainty on all measurements. A large discrepancy between emittances from wire scanners and luminosity was discovered but not solved. During Long Shutdown 1 the wire scanner system was upgraded with new photomultipliers. A thorough study of LHC wire scanner measurement precision in 2015 is presented

  20. Improved contrast deep optoacoustic imaging using displacement-compensated averaging: breast tumour phantom studies

    Energy Technology Data Exchange (ETDEWEB)

    Jaeger, M; Preisser, S; Kitz, M; Frenz, M [Institute of Applied Physics, University of Bern, Sidlerstrasse 5, CH-3012 Bern (Switzerland); Ferrara, D; Senegas, S; Schweizer, D, E-mail: frenz@iap.unibe.ch [Fukuda Denshi Switzerland AG, Reinacherstrasse 131, CH-4002 Basel (Switzerland)

    2011-09-21

    For real-time optoacoustic (OA) imaging of the human body, a linear array transducer and reflection mode optical irradiation is usually preferred. Such a setup, however, results in significant image background, which prevents imaging structures at the ultimate depth determined by the light distribution and the signal noise level. Therefore, we previously proposed a method for image background reduction, based on displacement-compensated averaging (DCA) of image series obtained when the tissue sample under investigation is gradually deformed. OA signals and background signals are differently affected by the deformation and can thus be distinguished. The proposed method is now experimentally applied to image artificial tumours embedded inside breast phantoms. OA images are acquired alternately with pulse-echo images using a combined OA/echo-ultrasound device. Tissue deformation is accessed via speckle tracking in pulse echo images, and used to compensate in the OA images for the local tissue displacement. In that way, OA sources are highly correlated between subsequent images, while background is decorrelated and can therefore be reduced by averaging. We show that image contrast in breast phantoms is strongly improved and detectability of embedded tumours significantly increased, using the DCA method.

  1. Cooperative spontaneous emission of nano-emitters with inter-emitter coupling in a leaky microcavity

    International Nuclear Information System (INIS)

    Hong, Suc-Kyoung; Nam, Seog Woo; Yang, Hyung Jin

    2015-01-01

    We study the spontaneous emission from a few two-level nano-emitters placed in a leaky microcavity with Lorentzian spectral density near a critically damped regime. Collective features of the spontaneous emission are investigated by numerical analysis of the excitation dynamics when initially one nano-emitter is totally excited but we do not know which one. The results show that there are three decay rates in the excitation dynamics, two for simple exponential decays and one for damped oscillatory decay. The excitation dynamics is found to critically depend on the regime of the system. It is shown that the spontaneous emission is enhanced or suppressed depending on whether the system is in the underdamped or overdamped regime, respectively. On the other hand, the cooperative spontaneous emission is suppressed in the underdamped while it is enhanced in the overdamped regime. Furthermore, the effect of the direct inter-emitter coupling on the breaking of the cooperativeness of the spontaneous emission is shown as well. (paper)

  2. Emittance growth and tune spectra at PETRA III

    International Nuclear Information System (INIS)

    Wanzenberg, R.

    2011-08-01

    At DESY the PETRA ring has been converted into a synchrotron radiation facility, called PETRA III. 20 damping wigglers have been installed to achieve an emittance of 1 nm. The commissioning with beam started in April 2009 and user runs have been started in 2010. The design current is 100 mA and the bunch to bunch distance is 8 ns for one particular filling pattern with 960 bunches. At a current of about 50 mA a strong vertical emittance increase has been observed. During machine studies it was found that the emittance increase depends strongly on the bunch filling pattern. For the user operation a filling scheme has been found which mitigates the increase of the vertical emittance. In August 2010 PETRA III has been operated without damping wigglers for one week. The vertical emittance growth was not significantly smaller without wigglers. Furthermore tune spectra at PETRA III show characteristic lines which have been observed at other storage rings in the connection with electron clouds. Measurements at PETRA III are presented for different bunch filling patterns and with and without wiggler magnets. (orig.)

  3. Transverse emittance growth in staged laser-wakefield acceleration

    Directory of Open Access Journals (Sweden)

    T. Mehrling

    2012-11-01

    Full Text Available We present a study on the emittance evolution of electron bunches, externally injected into laser-driven plasma waves using the three-dimensional particle-in-cell (PIC code OSIRIS. Results show order-of-magnitude transverse emittance growth during the injection process, if the electron bunch is not matched to its intrinsic betatron motion inside the wakefield. This behavior is supported by analytic theory reproducing the simulation data to a percent level. The length over which the full emittance growth develops is found to be less than or comparable to the typical dimension of a single plasma module in current multistage designs. In addition, the analytic theory enables the quantitative prediction of emittance degradation in two consecutive accelerators coupled by free-drift sections, excluding this as a scheme for effective emittance-growth suppression, and thus suggests the necessity of beam-matching sections between acceleration stages with fundamental implications on the overall design of staged laser-wakefield accelerators.

  4. Field emission characteristics of a small number of carbon fiber emitters

    Directory of Open Access Journals (Sweden)

    Wilkin W. Tang

    2016-09-01

    Full Text Available This paper reports an experiment that studies the emission characteristics of small number of field emitters. The experiment consists of nine carbon fibers in a square configuration. Experimental results show that the emission characteristics depend strongly on the separation between each emitter, providing evidence of the electric field screening effects. Our results indicate that as the separation between the emitters decreases, the emission current for a given voltage also decreases. The authors compare the experimental results to four carbon fiber emitters in a linear and square configurations as well as to two carbon fiber emitters in a paired array. Voltage-current traces show that the turn-on voltage is always larger for the nine carbon fiber emitters as compared to the two and four emitters in linear configurations, and approximately identical to the four emitters in a square configuration. The observations and analysis reported here, based on Fowler-Nordheim field emission theory, suggest the electric field screening effect depends critically on the number of emitters, the separation between them, and their overall geometric configuration.

  5. Factors that challenge health for people involved in the compensation process following a motor vehicle crash: A longitudinal study

    NARCIS (Netherlands)

    Elbers, N.A.; Akkermans, A.J.; Lockwood, K.; Craig, A.; Cameron, I.D.

    2014-01-01

    Background People who claim compensation after a motor vehicle accident do not recover as well as people with similar injuries who do not claim compensation. It has been suggested that this impeded recovery is caused by the stressful compensation process and the adversarial attitude of

  6. Transverse and longitudinal emittance measurements in the ELSA linac

    International Nuclear Information System (INIS)

    Loulergue, A.; Dowell, D.H.; Joly, S.; De Brion, J.P.; Haouat, G.; Schumann, F.

    1997-01-01

    The ELSA RF linac photoinjector has been designed to deliver high-brightness electron beams. The present paper deals with the transverse and longitudinal emittance measurements, at different locations along the ELSA beam line, and the analysis of their variations as a function of the photoinjector parameters : magnetic field generated by the anode focusing lens, bunch charge and pulse duration. While transverse emittance has been already studied in other similar installations, there has been little study of the electron beam longitudinal dynamics. Experimental results are presented and compared to simulation-code expectations. For 2.0 nC, 85 A electron bunches, a normalized rms emittance of 2 π mm mrad and a brightness of 4.5 x 10 13 A/(π m rad) 2 at the linac exit have been measured as well as less than 10 keV rms energy spread (or less than 0.1% at 16.5 MeV). (orig.)

  7. RF emittance in a low energy electron linear accelerator

    Science.gov (United States)

    Sanaye Hajari, Sh.; Haghtalab, S.; Shaker, H.; Kelisani, M. Dayyani

    2018-04-01

    Transverse beam dynamics of an 8 MeV low current (10 mA) S-band traveling wave electron linear accelerator has been studied and optimized. The main issue is to limit the beam emittance, mainly induced by the transverse RF forces. The linac is being constructed at Institute for Research in Fundamental Science (IPM), Tehran Iran Labeled as Iran's First Linac, nearly all components of this accelerator are designed and constructed within the country. This paper discusses the RF coupler induced field asymmetry and the corresponding emittance at different focusing levels, introduces a detailed beam dynamics design of a solenoid focusing channel aiming to reduce the emittance growth and studies the solenoid misalignment tolerances. In addition it has been demonstrated that a prebuncher cavity with appropriate parameters can help improving the beam quality in the transverse plane.

  8. Production of alpha emitters for therapy

    International Nuclear Information System (INIS)

    Vucina, J.; Orlic, M.; Lukic, D.

    2006-01-01

    The basis for the introduction of alpha emitters into nuclear medical practice are their radiobiological properties. High LET values and short ranges in biological tissues are advantageous in comparison with nowadays most often used beta emitters, primarily 90 Y and 131 I. Given are the most important criteria for the introduction of a given radionuclide in the routine use. Shown are the procedures for the production of the most important alpha emitters 211 At, 212 Bi and 213 Bi. (author)

  9. Emittance measurements by variable quadrupole method

    International Nuclear Information System (INIS)

    Toprek, D.

    2005-01-01

    The beam emittance is a measure of both the beam size and beam divergence, we cannot directly measure its value. If the beam size is measured at different locations or under different focusing conditions such that different parts of the phase space ellipse will be probed by the beam size monitor, the beam emittance can be determined. An emittance measurement can be performed by different methods. Here we will consider the varying quadrupole setting method.

  10. Iatrogenic nerve injury in a national no-fault compensation scheme: an observational cohort study.

    Science.gov (United States)

    Moore, A E; Zhang, J; Stringer, M D

    2012-04-01

    Iatrogenic nerve injury causes distress and disability, and often leads to litigation. The scale and profile of these injuries has only be estimated from published case reports/series and analyses of medicolegal claims.   To determine the current spectrum of iatrogenic nerve injury in New Zealand by analysing treatment injury claims accepted by a national no-fault compensation scheme. The Accident Compensation Corporation (ACC) provides national no-fault personal accident insurance cover, which extends to patients who have sustained a treatment injury from a registered healthcare professional. Nerve injury claims identified from 5227 treatment injury claims accepted by the ACC in 2009 were analysed. From 327 claims, 292 (89.3%) documenting 313 iatrogenic nerve injuries contained sufficient information for analysis. Of these, 211 (67.4%) occurred in 11 surgical specialties, particularly orthopaedics and general surgery; the remainder involved phlebotomy services, anaesthesia and various medical specialties. The commonest causes of injury were malpositioning (n = 40), venepuncture (n = 26), intravenous cannulation (n = 21) and hip arthroplasty (n = 21). Most commonly injured were the median nerve and nerve roots (n = 32 each), brachial plexus (n = 26), and the ulnar nerve (n = 25). At least 34 (11.6%) patients were referred for surgical management of their nerve injury. Iatrogenic nerve injuries are not rare and occur in almost all branches of medicine, with malpositioning under general anaesthesia and venepuncture as leading causes. Some of these injuries are probably unavoidable, but greater awareness of which nerves are at risk and in what context should facilitate the development and/or wider implementation of preventive strategies. © 2012 Blackwell Publishing Ltd.

  11. Influence of gravity compensation on kinematics and muscle activation patterns during reach and retrieval in subjects with cervical spinal cord injury: An explorative study

    OpenAIRE

    Marieke G . M. Kloosterman, PT, MSc; Govert J. Snoek, MD, PhD; Mirjam Kouwenhoven, MD; Anand V. Nene, MD, PhD; Michiel J. A. Jannink, PhD

    2010-01-01

    Many interventions in upper-limb rehabilitation after cervical spinal cord injury (CSCI) use arm support (gravity compensation); however, its specific effects on kinematics and muscle activation characteristics in subjects with a CSCI are largely unknown. We conducted a cross-sectional explorative study to study these effects. Nine subjects with a CSCI performed two goal-directed arm movements (maximal reach, reach and retrieval) with and without gravity compensation. Angles at elbow and shou...

  12. Minimum emittance in TBA and MBA lattices

    Science.gov (United States)

    Xu, Gang; Peng, Yue-Mei

    2015-03-01

    For reaching a small emittance in a modern light source, triple bend achromats (TBA), theoretical minimum emittance (TME) and even multiple bend achromats (MBA) have been considered. This paper derived the necessary condition for achieving minimum emittance in TBA and MBA theoretically, where the bending angle of inner dipoles has a factor of 31/3 bigger than that of the outer dipoles. Here, we also calculated the conditions attaining the minimum emittance of TBA related to phase advance in some special cases with a pure mathematics method. These results may give some directions on lattice design.

  13. Minimum emittance in TBA and MBA lattices

    International Nuclear Information System (INIS)

    Xu Gang; Peng Yuemei

    2015-01-01

    For reaching a small emittance in a modern light source, triple bend achromats (TBA), theoretical minimum emittance (TME) and even multiple bend achromats (MBA) have been considered. This paper derived the necessary condition for achieving minimum emittance in TBA and MBA theoretically, where the bending angle of inner dipoles has a factor of 3 1/3 bigger than that of the outer dipoles. Here, we also calculated the conditions attaining the minimum emittance of TBA related to phase advance in some special cases with a pure mathematics method. These results may give some directions on lattice design. (authors)

  14. Hybrid emitter all back contact solar cell

    Science.gov (United States)

    Loscutoff, Paul; Rim, Seung

    2016-04-12

    An all back contact solar cell has a hybrid emitter design. The solar cell has a thin dielectric layer formed on a backside surface of a single crystalline silicon substrate. One emitter of the solar cell is made of doped polycrystalline silicon that is formed on the thin dielectric layer. The other emitter of the solar cell is formed in the single crystalline silicon substrate and is made of doped single crystalline silicon. The solar cell includes contact holes that allow metal contacts to connect to corresponding emitters.

  15. Emittance measurements from the LLUMC proton accelerator

    International Nuclear Information System (INIS)

    Coutrakon, G.; Gillespie, G.H.; Hubbard, J.; Sanders, E.

    2005-01-01

    A new method of calculating beam emittances at the extraction point of a particle accelerator is presented. The technique uses the optimization programs NPSOL and MINOS developed at Stanford University in order to determine the initial values of beam size, divergence and correlation parameters (i.e. beam sigma matrix, σ ij ) that best fit measured beam parameters. These σ ij elements are then used to compute the Twiss parameters α, β, and the phase space area, ε, of the beam at the extraction point. Beam size measurements in X and Y throughout the transport line were input to the optimizer along with the magnetic elements of bends, quads, and drifts. The σ ij parameters were optimized at the accelerator's extraction point by finding the best agreement between these measured beam sizes and those predicted by TRANSPORT. This expands upon a previous study in which a 'trial and error' technique was used instead of the optimizer software, and which yielded similar results. The Particle Beam Optics Laboratory (PBO Lab TM ) program used for this paper integrates particle beam optics and other codes into a single intuitive graphically-based computing environment. This new software provides a seamless interface between the NPSOL and MINOS optimizer and TRANSPORT calculations. The results of these emittance searches are presented here for the eight clinical energies between 70 and 250 MeV currently being used at LLUMC

  16. Space charge compensation in the Linac4 low energy beam transport line with negative hydrogen ions

    Energy Technology Data Exchange (ETDEWEB)

    Valerio-Lizarraga, Cristhian A., E-mail: cristhian.alfonso.valerio.lizarraga@cern.ch [CERN, Geneva (Switzerland); Departamento de Investigación en Física, Universidad de Sonora, Hermosillo (Mexico); Lallement, Jean-Baptiste; Lettry, Jacques; Scrivens, Richard [CERN, Geneva (Switzerland); Leon-Monzon, Ildefonso [Facultad de Ciencias Fisico-Matematicas, Universidad Autónoma de Sinaloa, Culiacan (Mexico); Midttun, Øystein [CERN, Geneva (Switzerland); University of Oslo, Oslo (Norway)

    2014-02-15

    The space charge effect of low energy, unbunched ion beams can be compensated by the trapping of ions or electrons into the beam potential. This has been studied for the 45 keV negative hydrogen ion beam in the CERN Linac4 Low Energy Beam Transport using the package IBSimu [T. Kalvas et al., Rev. Sci. Instrum. 81, 02B703 (2010)], which allows the space charge calculation of the particle trajectories. The results of the beam simulations will be compared to emittance measurements of an H{sup −} beam at the CERN Linac4 3 MeV test stand, where the injection of hydrogen gas directly into the beam transport region has been used to modify the space charge compensation degree.

  17. Emittance control in linear colliders

    International Nuclear Information System (INIS)

    Ruth, R.D.

    1991-05-01

    In this paper, we discuss the generation and control of the emittance in a next-generation linear collider. The beams are extracted from a damping ring and compressed in length by the first bunch compressor. They are then accelerated in a preaccelerator linac up to an energy appropriate for injection into a high gradient linac. In many designs this pre-acceleration is followed by another bunch compression to reach a short bunch. After acceleration in the linac, the bunches are finally focused transversely to a small spot. The proposed vertical beam sizes at the interaction point are the order of a few nanometers while the horizontal sizes are about a factor of 100 larger. This cross-sectional area is about a factor of 10 4 smaller than the SLC. However, the main question is: what are the tolerances to achieve such a small size, and how do they compare to present techniques for alignment and stability? These tolerances are very design dependent. Alignment tolerances in the linac can vary from 1 μm to 100 μm depending upon the basic approach. In this paper we discuss techniques of emittance generation and control which move alignment tolerances to the 100 μm range

  18. Takeovers and (Excess) CEO Compensation

    NARCIS (Netherlands)

    Feito Ruiz, Isabel; Renneboog, Luc

    2017-01-01

    We study if a CEO’s equity-based compensation affects the expected value generation in takeovers. When the objectives of management and shareholders are more aligned, as proxied by the use of equity-based compensation, more value-maximizing acquisitions are expected. Whereas in widely-held firms the

  19. Takeovers and (excess) CEO compensation

    NARCIS (Netherlands)

    Feito Ruiz, Isabel; Renneboog, Luc

    We study if a CEO’s equity-based compensation affects the expected value generation in takeovers. When the objectives of management and shareholders are more aligned, as proxied by the use of equity-based compensation, more value-maximizing acquisitions are expected. Whereas in widely-held firms the

  20. Beam emittance reduction during operation of Indus-2

    Energy Technology Data Exchange (ETDEWEB)

    Fakhri, Ali Akbar, E-mail: fakhri@rrcat.gov.in; Kant, Pradeep; Ghodke, A. D.; Singh, Gurnam [Raja Ramanna Centre for Advanced Technology, Indore 452 013 (India)

    2015-11-15

    Indus-2 storage ring is a 2.5 GeV third generation synchrotron radiation source. This source was commissioned using a moderate optics. Beam injection was accomplished using an off momentum electron beam to avoid difficulties faced in storage of beam at 550 MeV. The injection procedure and relevant beam dynamical studies are discussed. The switch over from the moderate optics to low emittance optics is done at 2.5 GeV after storing the electron beam. The procedure evolved to reduce the beam emittance and its implementation during the operation is discussed.

  1. Mirrorless lasing from light emitters in percolating clusters

    Science.gov (United States)

    Burlak, Gennadiy; Rubo, Y. G.

    2015-07-01

    We describe the lasing effect in the three-dimensional percolation system, where the percolating cluster is filled by active media composed by light emitters excited noncoherently. We show that, due to the presence of a topologically nontrivial photonic structure, the stimulated emission is modified with respect to both conventional and random lasers. The time dynamics and spectra of the lasing output are studied numerically with finite-difference time-domain approach. The Fermat principle and Monte Carlo approach are applied to characterize the optimal optical path and interconnection between the radiating emitters. The spatial structure of the laser mode is found by a long-time FDTD simulation.

  2. Low emittance electron beam formation with a 17 GHz RF gun

    Directory of Open Access Journals (Sweden)

    W. J. Brown

    2001-08-01

    Full Text Available We report on electron beam quality measurement results from the Massachusetts Institute of Technology 17 GHz RF gun experiment. The 1.5 cell RF gun uses a solenoid for emittance compensation. It has produced bunch charges up to 0.1 nC with beam energies up to 1 MeV. The normalized rms emittance of the beam after 35 cm of transport from the gun has been measured by a slit technique to be 3π mm mrad for a 50 pC bunch. This agrees well with PARMELA simulations at these beam energies. At the exit of the electron gun, we estimate the emittance to be about 1π mm mrad, which corresponds to a beam brightness of about 80 A/(π mm mrad^{2}. Improved beam quality should be possible with a higher energy output electron beam from the gun.

  3. Intermediate energies heavy ion collisions : study of the charged particles emission dynamics and emitters characterization; Collisions d`ions lourds aux energies intermediaires: etude de la dynamique d`emission des particules chargees et caracterisation des emetteurs

    Energy Technology Data Exchange (ETDEWEB)

    Bauge, E

    1994-07-01

    In heavy ion collisions at intermediate energies, reaction processes are ranging from slow processes where equilibrium is achieved between every emission, up to direct processes where nucleon nucleon scattering and phase space availability are the deciding factors. In order to investigate this transition, both the emission dynamics and the characteristics of the emitter have been studied, both theoretically and experimentally in the AMPHORA detector, for the systems 7, 17, 27 and 34 AMeV, {sup 40}Ar+Al, {sup 40}Ar+Cu and {sup 40}Ar+Ag. First, the linear momentum transfer of the most central collisions has been evaluated for these systems, by measuring the velocity of heavy residues. Then, by measuring azimuthal angle correlations functions, and by comparing them with statistical model predictions, the average angular momentum of the emitter has been evaluated. To study the charged particles emission dynamics, experimental azimuthal angle and relative momentum correlation functions have been compared with simulations based on a classical trajectory model. Finally, predictions of an advanced BUU model have been studied for the system 34 AMeV 40 Ar+Al. (authors). 69 refs., 52 figs., 5 tabs.

  4. Boundary conditions on the plasma emitter surface in the presence of a particle counter flow: I. Ion emitter

    Energy Technology Data Exchange (ETDEWEB)

    Astrelin, V. T., E-mail: V.T.Astrelin@inp.nsk.su; Kotelnikov, I. A. [Russian Academy of Sciences, Budker Institute of Nuclear Physics, Siberian Branch (Russian Federation)

    2017-02-15

    Emission of positively charged ions from a plasma emitter irradiated by a counterpropagating electron beam is studied theoretically. A bipolar diode with a plasma emitter in which the ion temperature is lower than the electron temperature and the counter electron flow is extracted from the ion collector is calculated in the one-dimensional model. An analog of Bohm’s criterion for ion emission in the presence of a counterpropagating electron beam is derived. The limiting density of the counterpropagating beam in a bipolar diode operating in the space-charge-limited-emission regime is calculated. The full set of boundary conditions on the plasma emitter surface that are required for operation of the high-current optics module in numerical codes used to simulate charged particle sources is formulated.

  5. Drip irrigation emitter clogging in Dutch greenhouses as affected by methane and organic acids

    NARCIS (Netherlands)

    Kreij, de C.; Burg, van der A.M.M.; Runia, W.T.

    2003-01-01

    It is believed that the serious clogging of drip irrigation emitters in the Dutch greenhouse industry is caused by methane-oxidising bacteria and/or organic acids used as anti-clogging agents. In this study greenhouses with moderate to severe emitter clogging have been examined. High methane

  6. Tellurium adsorption on single crystal faces of molybdenum and tungsten field emitters

    International Nuclear Information System (INIS)

    Collins, R.A.; Kiwanga, C.A.

    1978-01-01

    The purpose of this letter is to report the extension of previous studies of Te adsorption on Mo and W field emitters to measurements on single crystal planes. The adsorption of semiconductors on metallic emitters has been found to be characterized by simultaneous decreases in emission current and the Fowler-Nordheim work function for adsorbate coverages of less than a monolayer. (Auth.)

  7. Optical characterization of OLED emitter properties by radiation pattern analyses

    Energy Technology Data Exchange (ETDEWEB)

    Flaemmich, Michael

    2011-09-08

    Researches in both, academia and industry are investigating optical loss channels in OLED layered systems by means of optical simulation tools in order to derive promising concepts for a further enhancement of the overall device performance. Besides other factors, the prospects of success of such optimization strategies rely severely on the credibility of the optical input data. The present thesis provides a guideline to measure the active optical properties of OLED emitter materials in situ by radiation pattern analyses. Reliable and widely applicable methods are introduced to determine the internal electroluminescence spectrum, the profile of the emission zone, the dipole emitter orientation, and the internal luminescence quantum efficiency of emissive materials from the optical far field emission of OLEDs in electrical operation. The proposed characterization procedures are applied to sets of OLEDs containing both, fluorescent polymeric materials as well as phosphorescent small-molecular emitters, respectively. On the one hand, quite expected results are obtained. On the other hand, several novel and truly surprising results are found. Most importantly, this thesis contains the first report of a non-isotropic, mainly parallel emitter orientation in a phosphorescent small-molecular guest-host system (Ir(MDQ)2(acac) in a-NPD). Due to the latter result, emitter orientation based optimization of phosphorescent OLEDs seems to be within reach. Since parallel dipoles emit preferably into air, the utilization of smart emissive materials with advantageous molecular orientation is capable to boost the efficiency of phosphorescent OLEDs by 50%. Materials design, the influence of the matrix material and the substrate, as well as film deposition conditions are just a few parameters that need to be studied further in order to exploit the huge potential of the dipole emitter orientation in phosphorescent OLEDs.

  8. Studies on the nondestructive emittance measurement at a negative-hydrogen-ion beam; Untersuchungen zur zerstoerungsfreien Emittanzmessung an einem negativen Wasserstoffionenstrahl

    Energy Technology Data Exchange (ETDEWEB)

    Gabor, C.

    2007-07-01

    In the present thesis the already known idea to apply photodetechment for the diagnosis at a H{sup -} beam has be newly interpretated and improved. Thereby a nondestructive emittance measurement method was developed, which is especially suited for future high-current accelerator projects. For emittance measurements thereby mechanical components can be totally abandoned, if at a small part of the H{sup -} ions the additional with only 0.754 eV weak bound electron is separated by photodetachment {Dirac_h}{omega}+H{sup -}{yields}H{sup 0}+e{sup -}. The neutralized H{sup -} ions can be magnetically or electrostatically separated from the electrons and the remaining H{sup -} ions. Especially the neutral particles are offered by their insensitivity against external electromagnetic fields for the determination of the phase-space distribution of the ion beam. Also the momentum transfer by photodetechment can be neglected at the neutralized ions. The detection of the divergence angle has been pursued by a scintillator with a CCD camera. For the calculation of the number of neutralized particles a simplified model under assumption of homogeneous density distributions was developed. The aim of the approximation was to make statements about the requirement on the laser system and the detector. Thereby especially the suitability of the measurement for high beam currents and beam parameters, as they are typically present behind a RFQ. Further aspects like the influence of the angle between laser and ion beams, relativistic ion beam, as well as the position and angular resolution have been also object of the discussion.

  9. Preliminary study on helical CT algorithms for patient motion estimation and compensation

    International Nuclear Information System (INIS)

    Wang, G.; Vannier, M.W.

    1995-01-01

    Helical computed tomography (helical/spiral CT) has replaced conventional CT in many clinical applications. In current helical CT, a patient is assumed to be rigid and motionless during scanning and planar projection sets are produced from raw data via longitudinal interpolation. However, rigid patient motion is a problem in some cases (such as in the skull base and temporal bone imaging). Motion artifacts thus generated in reconstructed images can prevent accurate diagnosis. Modeling a uniform translational movement, the authors address how patient motion is ascertained and how it may be compensated. First, mismatch between adjacent fan-beam projections of the same orientation is determined via classical correlation, which is approximately proportional to the patient displacement projected onto an axis orthogonal to the central ray of the involved fan-beam. Then, the patient motion vector (the patient displacement per gantry rotation) is estimated from its projections using a least-square-root method. To suppress motion artifacts, adaptive interpolation algorithms are developed that synthesize full-scan and half-scan planar projection data sets, respectively. In the adaptive scheme, the interpolation is performed along inclined paths dependent upon the patient motion vector. The simulation results show that the patient motion vector can be accurately and reliably estimated using their correlation and least-square-root algorithm, patient motion artifacts can be effectively suppressed via adaptive interpolation, and adaptive half-scan interpolation is advantageous compared with its full-scale counterpart in terms of high contrast image resolution

  10. Study on transient beam loading compensation for China ADS proton linac injector II

    Science.gov (United States)

    Gao, Zheng; He, Yuan; Wang, Xian-Wu; Chang, Wei; Zhang, Rui-Feng; Zhu, Zheng-Long; Zhang, Sheng-Hu; Chen, Qi; Powers, Tom

    2016-05-01

    Significant transient beam loading effects were observed during beam commissioning tests of prototype II of the injector for the accelerator driven sub-critical (ADS) system, which took place at the Institute of Modern Physics, Chinese Academy of Sciences, between October and December 2014. During these tests experiments were performed with continuous wave (CW) operation of the cavities with pulsed beam current, and the system was configured to make use of a prototype digital low level radio frequency (LLRF) controller. The system was originally operated in pulsed mode with a simple proportional plus integral and deviation (PID) feedback control algorithm, which was not able to maintain the desired gradient regulation during pulsed 10 mA beam operations. A unique simple transient beam loading compensation method which made use of a combination of proportional and integral (PI) feedback and feedforward control algorithm was implemented in order to significantly reduce the beam induced transient effect in the cavity gradients. The superconducting cavity field variation was reduced to less than 1.7% after turning on this control algorithm. The design and experimental results of this system are presented in this paper. Supported by National Natural Science Foundation of China (91426303, 11525523)

  11. A phantom study of dose compensation behind hip prosthesis using portal dosimetry and dynamic MLC

    International Nuclear Information System (INIS)

    Nielsen, Martin Skovmos; Carl, Jesper; Nielsen, Jane

    2008-01-01

    Background and purpose: A dose compensation method is presented for patients with hip prosthesis based on Dynamic Multi Leaves Collimator (DMLC) planning. Calculations are done from an exit Portal Dose Image (PDI) from 6 MV Photon beam using an Electronic Portal Imaging Device (EPID) from Varian. Four different hip prostheses are used for this work. Methods: From an exit PDI the fluence needed to yield a uniform dose distribution behind the prosthesis is calculated. To back-project the dose distribution through the phantom, the lateral scatter is removed by deconvolution with a point spread function (PSF) determined for depths from 10 to 40 cm. The dose maximum, D max , is determined from the primary plan which delivers the PDI. A further deconvolution to remove the dose glare effect in the EPID is performed as well. Additionally, this calculated fluence distribution is imported into the Treatment Planning System (TPS) for the final calculation of a DMLC plan. The fluence file contains information such as the relative central axis (CAX) position, grid size and fluence size needed for correct delivery of the DMLC plan. GafChromic EBT films positioned at 10 cm depth are used as verification of uniform dose distributions behind the prostheses. As the prosthesis is positioned at the phantom surface the dose verifications are done 10 cm from the prosthesis. Conclusion: The film measurement with 6 MV photon beam shows uniform doses within 5% for most points, but with hot/cold spots of 10% near the femoral head prostheses

  12. Positron emitter labeled enzyme inhibitors

    International Nuclear Information System (INIS)

    Fowler, J.S.; MacGregor, R.R.; Wolf, A.P.; Langstrom, B.

    1990-01-01

    This invention involves a new strategy for imagining and mapping enzyme activity in the living human and animal body using positron emitter-labeled suicide enzyme inactivators or inhibitors which become covalently bound to the enzyme as a result of enzymatic catalysis. Two such suicide inactivators for monoamine oxidase have been labeled with carbon-11 and used to map the enzyme subtypes in the living human and animal body using PET. By using positron emission tomography to image the distribution of radioactivity produced by the body penetrating radiation emitted by carbon-11, a map of functionally active monoamine oxidase activity is obtained. Clorgyline and L-deprenyl are suicide enzyme inhibitors and irreversibly inhibit monoamine oxidase. When these inhibitors are labeled with carbon-11 they provide selective probes for monoamine oxidase localization and reactivity in vivo using positron emission tomography

  13. High current plasma electron emitter

    International Nuclear Information System (INIS)

    Fiksel, G.; Almagri, A.F.; Craig, D.

    1995-07-01

    A high current plasma electron emitter based on a miniature plasma source has been developed. The emitting plasma is created by a pulsed high current gas discharge. The electron emission current is 1 kA at 300 V at the pulse duration of 10 ms. The prototype injector described in this paper will be used for a 20 kA electrostatic current injection experiment in the Madison Symmetric Torus (MST) reversed-field pinch. The source will be replicated in order to attain this total current requirement. The source has a simple design and has proven very reliable in operation. A high emission current, small size (3.7 cm in diameter), and low impurity generation make the source suitable for a variety of fusion and technological applications

  14. Mitigating the Effect of an Orbit Kink on Vertical Emittance and Polarization

    CERN Document Server

    Koop, I

    2015-01-01

    Orbit kinks in FCC tunnel are under discussions for they can help to reduce the depth of few shafts [1]. Still two unwanted effects could make their use completely forbidden. The vertical emittance growth due to vertical bending and vertical dispersion is one of these concerns [2]. Another concern is the need to somehow compensate strong distortions of spin motion [3]. Here I present an idea of how we can simultaneously solve both these problems.

  15. Radiation dosimetry in radiotherapy with internal emitters

    International Nuclear Information System (INIS)

    Stabin, Michael G.

    1997-01-01

    Full text. Radiation dosimetry radionuclides are currently being labeled to various biological agents used in internal emitter radiotherapy. This talk will review the various technologies and types of radiolabel in current use, with focus on the characterization of the radiation dose to the various important tissues of the body. Methods for obtaining data, developing kinetic models, and calculating radiation doses will be reviewed. Monoclonal antibodies are currently being labeled with both alpha and beta emitting radionuclides in attempts to find effective agents against cancer. Several radionuclides are also being used as bone pain palliation agents. These agents must be studied in clinical trials to determine the biokinetics and radiation dosimetry prior to approval for general use. In such studies, it is important to ensure the collection of the appropriate kinds of data and to collect the data at appropriate time intervals. The uptake and retention of activity in all significant source organs and in excreta be measured periodically (with at least 2 data points phase of uptake or clearance). Then, correct dosimetry methods must be applied - the best available methods for characterizing the radionuclide kinetic and for estimating the dosimetry in the various organs of the body especially the marrow, should be used. Attempts are also under way to develop methods for estimating true patient-specific dosimetry. Cellular and animal studies are also. Valuable in evaluating the efficacy of the agents in shrinking or eliminating tumors; some results from such studies will also be discussed. The estimation of radiation doses to patients in therapy with internal emitters involves several complex phases of analysis. Careful attention to detail and the use of the best available methods are essential to the protection of the patient and a successful outcome

  16. Fabrication of multi-emitter array of CNT for enhancement of current density

    Energy Technology Data Exchange (ETDEWEB)

    Chouhan, Vijay, E-mail: vchouhan@post.kek.jp [Department of Accelerator Science, Graduate University for Advanced Studies, 1-1 Oho, Tsukuba, Ibaraki (Japan); Noguchi, Tsuneyuki [High Energy Accelerator Research Organization-KEK, 1-1 Oho, Tsukuba, Ibaraki (Japan); Kato, Shigeki [Department of Accelerator Science, Graduate University for Advanced Studies, 1-1 Oho, Tsukuba, Ibaraki (Japan); High Energy Accelerator Research Organization-KEK, 1-1 Oho, Tsukuba, Ibaraki (Japan)

    2011-11-11

    We studied and compared field emission properties of two kinds of emitters of randomly oriented multi-wall carbon nanotubes (MWNTs), viz. continuous film emitter (CFE) and multi-emitter array (MEA). The CFE has a continuous film of MWNTs while the MEA consists of many equidistant small circular emitters. Both types of emitters were prepared by dispersing MWNTs over a titanium (Ti) film (for CFEs) or Ti circular islands (for MEAs) deposited on tantalum (Ta) followed by rooting of MWNTs into the Ti film or the Ti islands at high temperature. Emission properties of both types of emitters were analyzed with changing their emission areas. In case of the CFEs, current density decreased with an increase in emission area whereas consistent current densities were achieved from MEAs with different emission areas. In other words, the total emission current was achieved in proportion to the emission area in the case of MEAs. Additionally a high current density of 22 A/cm{sup 2} was achieved at an electric field of 8 V/{mu}m from MEAs, which was far better than that obtained from CFEs. The high current density in MEAs was attributed to edge effect, in which higher emission current is achieved from the edge of film emitter. The results indicate that the field emission characteristics can be greatly improved if a cathode contains many small equidistant circular emitters instead of a continuous film. The outstanding stability of the CFE and the MEA has been demonstrated for 2100 and 1007 h, respectively.

  17. Strong coupling of collection of emitters on hyperbolic meta-material

    Science.gov (United States)

    Biehs, Svend-Age; Xu, Chenran; Agarwal, Girish S.

    2018-04-01

    Recently, considerable effort has been devoted to the realization of a strong coupling regime of the radiation matter interaction in the context of an emitter at a meta surface. The strong interaction is well realized in cavity quantum electrodynamics, which also show that strong coupling is much easier to realize using a collection of emitters. Keeping this in mind, we study if emitters on a hyperbolic meta materials can yield a strong coupling regime. We show that strong coupling can be realized for densities of emitters exceeding a critical value. A way to detect strong coupling between emitters and hyperbolic metamaterials is to use the Kretschman-Raether configuration. The strong coupling appears as the splitting of the reflectivity dip. In the weak coupling regime, the dip position shifts. The shift and splitting can be used to sense active molecules at surfaces.

  18. Gamma emitters in Hong Kong water

    International Nuclear Information System (INIS)

    Shun-Yin, L.; Chung-Keung, M.; Wai-Kwok, N.; Shiu-Chun, A.

    1990-01-01

    Radioactivity in water originates from natural and artificial sources. The development of a nuclear powerplant near Hong Kong necessitates that attention be given to formulating techniques to assess the possible resultant environmental radioactive contamination. Water samples collected from various sites in Hong Kong in the spring and summer of 1987, representing seawater, river water, reservoir water, drinking water, and underground water were studied through gamma-ray spectral analysis. Only gamma emitters in the U238 and Th232 series and K40 were detected. No fission product was detected with specific activity above 0.1 Bq/kg. The data could be the baseline for future monitoring of the radioactivity released from a nuclear plant being built at a 50-km distance from Hong Kong. The variation of detected specific activities may be due to geological differences and the effect of plants. 1 ref., 3 tabs

  19. Reactive power compensating system

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Timothy J. (Redondo Beach, CA); El-Sharkawi, Mohamed A. (Renton, WA); Venkata, Subrahmanyam S. (Seattle, WA)

    1987-01-01

    The reactive power of an induction machine is compensated by providing fixed capacitors on each phase line for the minimum compensation required, sensing the current on one line at the time its voltage crosses zero to determine the actual compensation required for each phase, and selecting switched capacitors on each line to provide the balance of the compensation required.

  20. Effect of high-pitch dual-source CT to compensate motion artifacts: a phantom study.

    Science.gov (United States)

    Farshad-Amacker, Nadja A; Alkadhi, Hatem; Leschka, Sebastian; Frauenfelder, Thomas

    2013-10-01

    To evaluate the potential of high-pitch, dual-source computed tomography (DSCT) for compensation of motion artifacts. Motion artifacts were created using a moving chest/cardiac phantom with integrated stents at different velocities (from 0 to 4-6 cm/s) parallel (z direction), transverse (x direction), and diagonal (x and z direction combined) to the scanning direction using standard-pitch (SP) (pitch = 1) and high-pitch (HP) (pitch = 3.2) 128-detector DSCT (Siemens, Healthcare, Forchheim, Germany). The scanning parameters were (SP/HP): tube voltage, 120 kV/120 kV; effective tube current time product, 300 mAs/500 mAs; and a pitch of 1/3.2. Motion artifacts were analyzed in terms of subjective image quality and object distortion. Image quality was rated by two blinded, independent observers using a 4-point scoring system (1, excellent; 2, good with minor object distortion or blurring; 3, diagnostically partially not acceptable; and 4, diagnostically not acceptable image quality). Object distortion was assessed by the measured changes of the object's outer diameter (x) and length (z) and a corresponding calculated distortion vector (d) (d = √(x(2) + z(2))). The interobserver agreement was excellent (k = 0.91). Image quality using SP was diagnostically not acceptable with any motion in x direction (scores 3 and 4), in contrast to HP DSCT where it remained diagnostic up to 2 cm/s (scores 1 and 2). For motion in the z direction only, image quality remained diagnostic for SP and HP DSCT (scores 1 and 2). Changes of the object's diameter (x), length (z), and distortion vectors (d) were significantly greater with SP (overall: x = 1.9 cm ± 1.7 cm, z = 0.6 cm ± 0.8 cm, and d = 1.4 cm ± 1.5 cm) compared to HP DSCT (overall: x = 0.1 cm ± 0.1 cm, z = 0.0 cm ± 0.1 cm, and d = 0.1 cm ± 0.1 cm; each P pitch DSCT significantly decreases motion artifacts in various directions and improves image quality. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  1. The perceptions and experiences of people injured in motor vehicle crashes in a compensation scheme setting: a qualitative study.

    Science.gov (United States)

    Murgatroyd, Darnel; Lockwood, Keri; Garth, Belinda; Cameron, Ian D

    2015-04-25

    The evidence that compensation related factors are associated with poor recovery is substantial but these measures are generic and do not consider the complexity of scheme design. The objectives of this study were to understand people's perceptions and experiences of the claims process after sustaining a compensable injury in a motor vehicle crash (including why people seek legal representation); and to explore ways to assist people following a compensable injury and improve their experience with the claims process. A qualitative study in a Compulsory Third Party (CTP) personal injury scheme covering the state of New South Wales (NSW), Australia. A series of five focus groups, with a total of 32 participants who had sustained mild to moderate injuries in a motor vehicle crash, were conducted from May to June 2011 with four to eight attendees in each group. These were audio-recorded and transcribed. The methodology was based on a grounded theory approach using thematic analysis and constant comparison to generate coding categories for themes. Data saturation was reached. Analyst triangulation was used to ensure credibility of the results. Five primary themes were identified: complexity of the claims process; requirement of legal representation; injury recovery expectations; importance of timely healthcare decision making; and improvements for injury recovery. Some participants struggled, finding the claims process stressful and subsequently sought legal advice; whilst others reported a straight forward recovery, helpful insurer interactions and no legal representation. Most participants were influenced by injury recovery expectations, and timely healthcare decision making. To assist with injury recovery, access to objective information about the claims process using online technology and social media was considered paramount. Participants had contrasting injury recovery experiences and their perceptions of the claims process differed and were influenced by injury

  2. Beam diagnostics using an emittance measurement device

    International Nuclear Information System (INIS)

    Sarstedt, M.; Becker, R.; Klein, H.; Maaser, A.; Mueller, J.; Thomae, R.; Weber, M.

    1995-01-01

    For beam diagnostics aside from Faraday cups for current measurements and analysing magnets for the determination of beam composition and energy the most important tool is an emittance measurement device. With such a system the distribution of the beam particles in phase-space can be determined. This yields information not only on the position of the particles but also on their angle with respect to the beam axis. There are different kinds of emittance measurement devices using either circular holes or slits for separation of part of the beam. The second method (slit-slit measurement), though important for the determination of the rms-emittance, has the disadvantage of integrating over the y- and y'-coordinate (measurement in xx'-plane assumed). This leads to different emittance diagrams than point-point measurements, since in xx'-plane for each two corresponding points of rr'-plane there exists a connecting line. With regard to beam aberrations this makes xx'-emittances harder to interpret. In this paper the two kinds of emittance diagrams are discussed. Additionally the influence of the slit height on the xx'-emittance is considered. The analytical results are compared to experimental measurements in rr'-, rx'- and xx'-phase-space. (orig.)

  3. Emittance Measurements from a Laser Driven Electron Injector

    CERN Document Server

    Reis, D

    2003-01-01

    The Gun Test Facility (GTF) at the Stanford Linear Accelerator Center was constructed to develop an appropriate electron beam suitable for driving a short wavelength free electron laser (FEL) such as the proposed Linac Coherent Light Source (LCLS). For operation at a wavelength of 1.5 (angstrom), the LCLS requires an electron injector that can produce an electron beam with approximately 1 pi mm-mrad normalized rms emittance with at least 1 nC of charge in a 10 ps or shorter bunch. The GTF consists of a photocathode rf gun, emittance-compensation solenoid, 3 m linear accelerator (linac), drive laser, and diagnostics to measure the beam. The rf gun is a symmetrized 1.6 cell, s-band high gradient, room temperature, photocathode structure. Simulations show that this gun when driven by a temporally and spatially shaped drive laser, appropriately focused with the solenoid, and further accelerated in linac can produce a beam that meets the LCLS requirements. This thesis describes the initial characterization of the ...

  4. A study of influences of the workers' compensation and injury management regulations on aviation safety at a workplace.

    Science.gov (United States)

    Yadav, Devinder K; Nikraz, Hamid; Chen, Yongqing

    2016-01-01

    As the aviation industries developed, so too did the recognition that there must be an effective regulatory framework to address issues related to the workers' compensation and rehabilitation. All employees would like to work and return home safely from their workplace. Therefore, the efficient management of workplace injury and disease reduces the cost of aviation operations and improves flight safety. Workers' compensation and injury management laws regulate a majority of rehabilitation and compensation issues, but achieving an injury-free workplace remains a major challenge for the regulators. This paper examines the clauses of the workers' compensation and injury management laws of Western Australia related to workplace safety, compensation, and rehabilitations of the injured workers. It also discusses various provisions of common law under the relevant workers' health injury management legislations.

  5. Laser-assisted electron emission from gated field-emitters

    CERN Document Server

    Ishizuka, H; Yokoo, K; Mimura, H; Shimawaki, H; Hosono, A

    2002-01-01

    Enhancement of electron emission by illumination of gated field-emitters was studied using a 100 mW cw YAG laser at a wavelength of 532 nm, intensities up to 10 sup 7 W/m sup 2 and mechanically chopped with a rise time of 4 mu s. When shining an array of 640 silicon emitters, the emission current responded quickly to on-off of the laser. The increase of the emission current was proportional to the basic emission current at low gate voltages, but it was saturated at approx 3 mu A as the basic current approached 100 mu A with the increase of gate voltage. The emission increase was proportional to the square root of laser power at low gate voltages and to the laser power at elevated gate voltages. For 1- and 3-tip silicon emitters, the rise and fall of the current due to on-off of the laser showed a significant time lag. The magnitude of emission increase was independent of the position of laser spot on the emitter base and reached 2 mu A at a basic current of 5 mu A without showing signs of saturation. The mech...

  6. Beam emittance of the Stony Brook Tandem-LINAC booster

    International Nuclear Information System (INIS)

    Scholldorf, A.H.

    1984-01-01

    This dissertation is primarily a study of the longitudinal and transverse beam emittance of the Stony Brook Heavy Ion Tandem LINAC Accelerator Facility, with a secondary emphasis on the beam dynamical design of two key elements of the system: a low energy double-drift buncher, and an achromatic double-90 0 LINAC injection system. A transverse emittance measuring system consisting of two translation stages controlled by stepper motors is described. Each stage carried a pair of beam defining slits mounted so that both horizontal and vertical emittances could be measured with only linear motion of the stage assembly. Beam currents were measured directly by a low-noise, high-sensitivity electrometer circuit integrated with the second slit-stage assembly. A mini-computer controlled the motors and acquired and displayed the data. Transverse emittance areas of beams of 12 C, 16 O, 32 S, and 58 Ni were measured at ion source extraction potential, after ion source acceleration, after tandem acceleration, and after LINAC acceleration. The results were analyzed in terms of source sputter-cone geometry, angle straggling in gas and foil strippers, and a variety of other factors

  7. Auger electron emitters: Insights gained from in vitro experiments

    International Nuclear Information System (INIS)

    Makrigiorgos, G.; Adelstein, S.J.; Kassis, A.I.

    1990-01-01

    This paper outlines the evolution of the current rationale for research into the biological effects of tissue-incorporated Auger electron emitters. The first section is a brief review of the research conducted by several groups in the last fifteen years. The second section describes the in vitro model used in our studies, dosimetric calculations, experimental techniques and recent findings. The third section focuses on the use of Auger electron emitters as in vitro microprobes for the investigation of the radiosensitivity of distinct subcellular components. Examination of the biological effects of the Auger electron emitter 125 I located in different cellular compartments of a single cell line (V 79 hamster lung fibroblast) verifies that DNA is the critical cell structure for radiation damage and that the sensitive sites are of nanometer dimensions. The data from incorporation of several Auger electron emitters at the same location within DNA suggest that there are no saturation effects from the decay of these isotopes (i.e. all the emitted energy is biologically effective) and provide some insight into which of the numerous physical mechanisms accompanying the Auger decay are most important in causing cell damage. Finally the implications of Auger electron emission for radiotherapy and radiation protection in diagnostic nuclear medicine are detailed and further research possibilities are suggested. (orig.)

  8. An Experimental Study of Medical Error Explanations: Do Apology, Empathy, Corrective Action, and Compensation Alter Intentions and Attitudes?

    Science.gov (United States)

    Nazione, Samantha; Pace, Kristin

    2015-01-01

    Medical malpractice lawsuits are a growing problem in the United States, and there is much controversy regarding how to best address this problem. The medical error disclosure framework suggests that apologizing, expressing empathy, engaging in corrective action, and offering compensation after a medical error may improve the provider-patient relationship and ultimately help reduce the number of medical malpractice lawsuits patients bring to medical providers. This study provides an experimental examination of the medical error disclosure framework and its effect on amount of money requested in a lawsuit, negative intentions, attitudes, and anger toward the provider after a medical error. Results suggest empathy may play a large role in providing positive outcomes after a medical error.

  9. Beam emittance measurement from CERN thermionic guns

    International Nuclear Information System (INIS)

    Kester, O.; Rao, R.; Rinolfi, L.

    1992-01-01

    In the LEP Injector Linacs (LIL) a thermionic gun provides electron beams with different peak intensities at an energy of 80 keV. The beam emittances were estimated from the EGUN programme. Since the gun is of triode type, the main contribution to the emittance comes from the grid. The simulation programme does not model the real geometry by assuming a cylindrical symmetry, while the grid does not have such symmetry. A Gun Test Facility (GTF), allowing emittance measurements, based on the 3-gradients-method was installed. The experimental results are presented. (author) 6 refs.; 6 figs

  10. Normal spectral emittance of Inconel 718 aeronautical alloy coated with yttria stabilized zirconia films

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Fernandez, L. [Departamento de Fisica de la Materia Condensada, Facultad de Ciencia y Tecnologia, Universidad del Pais Vasco, Barrio Sarriena s/n, 48940 Leioa, Bizkaia (Spain); Industria de Turbo Propulsores, S.A., Planta de Zamudio, Edificio 300, 48170 Zamudio, Bizkaia (Spain); Campo, L. del [Departamento de Fisica de la Materia Condensada, Facultad de Ciencia y Tecnologia, Universidad del Pais Vasco, Barrio Sarriena s/n, 48940 Leioa, Bizkaia (Spain); Perez-Saez, R.B., E-mail: raul.perez@ehu.es [Departamento de Fisica de la Materia Condensada, Facultad de Ciencia y Tecnologia, Universidad del Pais Vasco, Barrio Sarriena s/n, 48940 Leioa, Bizkaia (Spain); Tello, M.J. [Departamento de Fisica de la Materia Condensada, Facultad de Ciencia y Tecnologia, Universidad del Pais Vasco, Barrio Sarriena s/n, 48940 Leioa, Bizkaia (Spain)

    2012-02-05

    Highlights: Black-Right-Pointing-Pointer Emittance of Inconel 718 coated with plasma sprayed yttria stabilized zirconia. Black-Right-Pointing-Pointer The coating is opaque for {lambda} > 9 {mu}m and semi-transparent for {lambda} < 9 {mu}m. Black-Right-Pointing-Pointer In the semi-transparent region the emittance decreases with coating thickness. Black-Right-Pointing-Pointer 300 {mu}m thick coatings are still semi-transparent. Black-Right-Pointing-Pointer In the opaque region the surface roughness determines the emittance level. - Abstract: Knowledge of the radiative behaviour of the yttria stabilized zirconia (YSZ) thermal barrier coatings (TBCs) is needed to perform radiative heat transfer calculations in industrial applications. In this paper, normal spectral emittance experimental data of atmospheric plasma sprayed (PS) YSZ films layered on Inconel 718 substrates are shown. The spectral emittance was measured between 2.5 and 22 {mu}m on samples with film thicknesses ranging from 20 to 280 {mu}m. The samples were heated in a controlled environment, and the emittance was measured for several temperatures between 330 and 730 Degree-Sign C. The dependence of the spectral emittance with film thickness, surface roughness and temperature has been studied and compared with the available results for YSZ TBCs obtained by electron-beam physical vapour deposition. The PS-TBC samples show a Christiansen point at {lambda} = 12.8 {mu}m. The films are semi-transparent for {lambda} < 9 {mu}m, and opaque for {lambda} > 9 {mu}m. In the semi-transparent region, the contribution of the radiation emitted by the Inconel 718 substrate to the global emittance of the samples is analysed. In addition, the influence of the roughness in the emittance values in the opaque spectral region is discussed. Finally, the total normal emittance is obtained as a function of the TBC thickness.

  11. Study on the Optimizing Operation of Exhaust Air Heat Recovery and Solar Energy Combined Thermal Compensation System for Ground-Coupled Heat Pump

    Directory of Open Access Journals (Sweden)

    Kuan Wang

    2017-01-01

    Full Text Available This study proposed an exhaust air heat recovery and solar energy combined thermal compensation system (ESTC for ground-coupled heat pumps. Based on the prediction of the next day’s exhaust air temperature and solar irradiance, an optimized thermal compensation (OTC method was developed in this study as well, in which the exhaust air heat recovery compensator and solar energy compensator in the ESTC system run at high efficiency throughout various times of day. Moreover, a modified solar term similar days group (STSDG method was proposed to improve the accuracy of solar irradiance prediction in hazy weather. This modified STSDG method was based on air quality forecast and AQI (air quality index correction factors. Through analyzing the operating parameters and the simulation results of a case study, the ESTC system proved to have good performance and high efficiency in eliminating the heat imbalance by using the OTC method. The thermal compensation quantity per unit energy consumption (TEC of ESTC under the proposed method was 1.25 times as high as that under the traditional operation method. The modified STSDG method also exhibited high accuracy. For the accumulated solar irradiance of the four highest daily radiation hours, the monthly mean absolute percentage error (MAPE between the predicted values and the measured values was 6.35%.

  12. Individualized FAC on bottom tab subassemblies to minimize adhesive gap between emitter and optics

    Science.gov (United States)

    Sauer, Sebastian; Müller, Tobias; Haag, Sebastian; Beleke, Andreas; Zontar, Daniel; Baum, Christoph; Brecher, Christian

    2017-02-01

    High Power Diode Laser (HPDL) systems with short focal length fast-axis collimators (FAC) require submicron assembly precision. Conventional FAC-Lens assembly processes require adhesive gaps of 50 microns or more in order to compensate for component tolerances (e.g. deviation of back focal length) and previous assembly steps. In order to control volumetric shrinkage of fast-curing UV-adhesives shrinkage compensation is mandatory. The novel approach described in this paper aims to minimize the impact of volumetric shrinkage due to the adhesive gap between HPDL edge emitters and FAC-Lens. Firstly, the FAC is actively aligned to the edge emitter without adhesives or bottom tab. The relative position and orientation of FAC to emitter are measured and stored. Consecutively, an individual subassembly of FAC and bottom tab is assembled on Fraunhofer IPT's mounting station with a precision of +/-1 micron. Translational and lateral offsets can be compensated, so that a narrow and uniform glue gap for the consecutive bonding process of bottom tab to heatsink applies (Figure 4). Accordingly, FAC and bottom tab are mounted to the heatsink without major shrinkage compensation. Fraunhofer IPT's department assembly of optical systems and automation has made several publications regarding active alignment of FAC lenses [SPIE LASE 8241-12], volumetric shrinkage compensation [SPIE LASE 9730-28] and FAC on bottom tab assembly [SPIE LASE 9727-31] in automated production environments. The approach described in this paper combines these and is the logical continuation of that work towards higher quality of HPDLs.

  13. Preservation of low slice emittance in bunch compressors

    Directory of Open Access Journals (Sweden)

    S. Bettoni

    2016-03-01

    Full Text Available Minimizing the dilution of the electron beam emittance is crucial for the performance of accelerators, in particular for free electron laser facilities, where the length of the machine and the efficiency of the lasing process depend on it. Measurements performed at the SwissFEL Injector Test Facility revealed an increase in slice emittance after compressing the bunch even for moderate compression factors. The phenomenon was experimentally studied by characterizing the dependence of the effect on beam and machine parameters relevant for the bunch compression. The reproduction of these measurements in simulation required the use of a 3D beam dynamics model along the bunch compressor that includes coherent synchrotron radiation. Our investigations identified transverse effects, such as coherent synchrotron radiation and transverse space charge as the sources of the observed emittance dilution, excluding other effects, such as chromatic effects on single slices or spurious dispersion. We also present studies, both experimental and simulation based, on the effect of the optics mismatch of the slices on the variation of the slice emittance along the bunch. After a corresponding reoptimization of the beam optics in the test facility we reached slice emittances below 200 nm for the central slices along the longitudinal dimension with a moderate increase up to 300 nm in the head and tail for a compression factor of 7.5 and a bunch charge of 200 pC, equivalent to a final current of 150 A, at about 230 MeV energy.

  14. Skew quad compensation at PEP

    International Nuclear Information System (INIS)

    Murray, J.J.

    1977-10-01

    Rotational and focal effects of solenoids used in PEP detectors will cause severe perturbations of machine beam optics and must be corrected. Ordinarily this would be accomplished by the addition of compensating solenoids and adjustment of insertion quadrupole strengths. It has been found that an arbitrary cross plane coupling representing the effects of solenoids and/or skew quads in any combination can be synthesized (or compensated) exactly using a quartet of skew quads combined with other erect transport elements in a wide variety of configurations. Specific skew quad compensating systems for PEP have been designed and are under study by PEP staff. So far no fundamental flaws have been discovered. In view of that, PEP management has tentatively authorized the use of such a system in the PEP-4, PEP-9 experiments and proposes to leave the question open ''without prejudice'' for other experiments. Use of skew quad compensation involves an imponderable risk, of course, simply because the method is new and untested. But in addition to providing the only known method for dealing with skew quad perturbations, skew quad compensation, as an alternate to compensating solenoids, promises to be much cheaper, to require much less power and to occupy much less space in the IR's. The purpose of this note is to inform potential users of the foregoing situation and to explain skew quad compensation more fully. 2 refs., 1 fig., 1 tab

  15. A comparison of leak compensation in acute care ventilators during noninvasive and invasive ventilation: a lung model study.

    Science.gov (United States)

    Oto, Jun; Chenelle, Christopher T; Marchese, Andrew D; Kacmarek, Robert M

    2013-12-01

    Although leak compensation has been widely introduced to acute care ventilators to improve patient-ventilator synchronization in the presence of system leaks, there are no data on these ventilators' ability to prevent triggering and cycling asynchrony. The goal of this study was to evaluate the ability of leak compensation in acute care ventilators during invasive and noninvasive ventilation (NIV). Using a lung simulator, the impact of system leaks was compared on 7 ICU ventilators and 1 dedicated NIV ventilator during triggering and cycling at 2 respiratory mechanics (COPD and ARDS models) settings, various modes of ventilation (NIV mode [pressure support ventilation], and invasive mode [pressure support and continuous mandatory ventilation]), and 2 PEEP levels (5 and 10 cm H(2)O). Leak levels used were up to 35-36 L/min in NIV mode and 26-27 L/min in invasive mode. Although all of the ventilators were able to synchronize with the simulator at baseline, only 4 of the 8 ventilators synchronized to all leaks in NIV mode, and 2 of the 8 ventilators in invasive mode. The number of breaths to synchronization was higher during increasing than during decreasing leak. In the COPD model, miss-triggering occurred more frequently and required a longer time to stabilize tidal volume than in the ARDS model. The PB840 required fewer breaths to synchronize in both invasive and noninvasive modes, compared with the other ventilators (P ventilators. The PB840 and the V60 were the only ventilators to acclimate to all leaks, but there were differences in performance between these 2 ventilators. It is not clear if these differences have clinical importance.

  16. Quercetin Feeding in Newborn Dairy Calves Cannot Compensate Colostrum Deprivation: Study on Metabolic, Antioxidative and Inflammatory Traits

    Science.gov (United States)

    Gruse, Jeannine; Kanitz, Ellen; Weitzel, Joachim M.; Tuchscherer, Armin; Stefaniak, Tadeusz; Jawor, Paulina; Wolffram, Siegfried; Hammon, Harald M.

    2016-01-01

    Immaturity of the neonatal immune system is causative for high morbidity in calves and colostrum intake is crucial for acquiring passive immunity. Pathogenesis is promoted by reactive oxygen species accumulating at birth if counter-regulation is inadequate. The flavonol quercetin exerts antioxidative and anti-inflammatory effects that may enhance neonatal health. The aim of this work was to study effects of quercetin feeding on metabolic, antioxidative and inflammatory parameters in neonatal calves to investigate whether quercetin could compensate for insufficient colostrum supply. Twenty-eight newborn calves were assigned to two dietary groups fed colostrum or milk-based formula on day 1 and 2 and milk replacer thereafter. From day 2 onwards, 7 calves per diet group were additionally fed quercetin aglycone (50 mg/(kg body weight × day)). Blood samples were taken repeatedly to measure plasma concentrations of flavonols, glucose, lactate, total protein, albumin, urea, non-esterified fatty acids, triglycerides, cholesterol, insulin, glucagon, cortisol, immunoglobulins, fibrinogen, haptoglobin and serum amyloid A. Trolox equivalent antioxidative capacity, ferric reducing ability of plasma, thiobarbituric acid reactive species and F2-isoprostanes were analyzed to evaluate plasma antioxidative status. Expression of tumor necrosis factor, interleukin-1α, interleukin-1β, serum amyloid A, haptoglobin, fibrinogen, C-reactive protein, catalase, glutathione peroxidase and superoxide dismutase mRNA were measured in liver tissue on day 8. Plasma flavonol concentrations were detectable only after quercetin-feeding without differences between colostrum and formula feeding. Plasma glucose, lactate, total protein, immunoglobulins, triglycerides, cholesterol, trolox equivalent antioxidative capacity and thiobarbituric acid reactive species were higher after colostrum feeding. Body temperature, fecal fluidity and plasma concentrations of cortisol and haptoglobin were higher in

  17. Compensating for non-response in a study estimating the incidence of mental disorders in long-term sickness absence by a two-phased design

    DEFF Research Database (Denmark)

    Søgaard, Hans Jørgen; Bech, Per

    2010-01-01

    AIMS: The study compensates for the non-response that was observed in a previous study that estimated the frequencies of mental disorders in long-term sickness absence (LSA) (more than eight weeks of continuous sickness absence). In this study, the frequency of any mental disorder was estimated a...

  18. Internal emitter research and standard setting

    International Nuclear Information System (INIS)

    Stannard, J.N.

    1981-01-01

    The history of the use of data from internal emitter research in the derivation of safety standards is reviewed. At first, observed biological effects were correlated with body burdens or exposure levels. This direct approach is illustrated by detailed accounts of the cases of uranium and plutonium. In the 1950's, when it was decided to provide standards for over 200 isotopes, the direct approach was replaced by a system of calculations. This necessitated changes in internal emitter research programs to provide metabolic data, and the development of models such as Reference Man and the Lung and Gastrointestinal Tract models. The continuing contribution of internal emitter research to standard setting can be seen in the references quoted in the metabolic data section of the new ICRP report (ICRP Publication 30). Present trends suggest a possible return to the direct use of internal emitter effects data for obtaining risk estimates. (U.K.)

  19. Beam emittance measurements on multicusp ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Sarstedt, M.; Lee, Y.; Leung, K.N. [and others

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 {mu}m patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma.

  20. Beam emittance measurements on multicusp ion sources

    International Nuclear Information System (INIS)

    Sarstedt, M.; Lee, Y.; Leung, K.N.

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 μm patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma

  1. Self-powered detectors with thulium emitter

    International Nuclear Information System (INIS)

    Haller, P.; Klar, E.

    1978-01-01

    In addition to fission chambers, prompt-indicating self-powered (SPN) detectors are used for measuring the neutron flux density in the core of power reactors. Although current SPN detectors with a cobalt emitter give satisfactora results, detectors with other emitter materials have been analyzed and tested. The author describes the properties and decay pattern of the nuclide thulium and presents the results of measurements made while testing thulium detectors. (orig.) [de

  2. Alpha-emitters for medical therapy workshop

    International Nuclear Information System (INIS)

    Feinendegen, L.E.; McClure, J.J.

    1996-01-01

    A workshop on ''Alpha-Emitters for Medical Therapy'' was held May 30-31, 1996 in Denver Colorado to identify research goals and potential clinical needs for applying alpha-particle emitters and to provide DOE with sufficient information for future planning. The workshop was attended by 36 participants representing radiooncology, nuclear medicine, immunotherapy, radiobiology, molecular biology, biochemistry, radiopharmaceutical chemistry, dosimetry, and physics. This report provides a summary of the key points and recommendations arrived at during the conference

  3. Alpha-emitters for medical therapy workshop

    Energy Technology Data Exchange (ETDEWEB)

    Feinendegen, L.E.; McClure, J.J.

    1996-12-31

    A workshop on ``Alpha-Emitters for Medical Therapy`` was held May 30-31, 1996 in Denver Colorado to identify research goals and potential clinical needs for applying alpha-particle emitters and to provide DOE with sufficient information for future planning. The workshop was attended by 36 participants representing radiooncology, nuclear medicine, immunotherapy, radiobiology, molecular biology, biochemistry, radiopharmaceutical chemistry, dosimetry, and physics. This report provides a summary of the key points and recommendations arrived at during the conference.

  4. Localization of alpha emitters by damage production in a thin film. Application to the study of alpha emitter diffusion in irradiated samples; Localisation des emetteurs alpha par creation de dommages dans un film mince. Application a l'etude de la diffusion des emetteurs alpha dans des echantillons irradies

    Energy Technology Data Exchange (ETDEWEB)

    Houdaille, B; Perrot, M [Commissariat a l' Energie Atomique, 91 - Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    The process of recording {alpha} particles on cellulose nitrate films, called alpha-graphy, is applied to the study of the diffusion of {alpha}-emitting elements in irradiated alloys. The existence of diffusion is shown by attacking the film with concentrated caustic soda after exposition. The insensitivity of the recorder to {beta} {gamma} radiation emitted by the sample after passing in the reactor makes it possible to operate with long exposure times and to detect small diffusions. The concentration-penetration curves are drawn up after carrying out a densitometric analysis of the alpha-graphies. - As the cellulose nitrate is affected only by {alpha} particles of energies of between 0.5 and 4 MeV, it was first necessary to determine the yield of the recorder for {alpha} particles emitted by a thick source, i.e. whose energy varies between 0 and E{sub 0}, E{sub 0} being the energy of the alpha emitter. - The concentration C of the {alpha}-emitter, as a function of the optical density D of the alpha-graphy, and of the exposure time t is given by a simple relationship: C = D/at where a is an experimental constant determined by calibration. It depends on the nature of the cellulose nitrate, of the {alpha}-emitting element and of the alloy studied. (authors) [French] Le procede d'enregistrement des particules alpha sur film de nitrate de cellulose, ou alphagraphie, est applique a l'etude de la diffusion d'elements emetteurs alpha dans des alliages irradies. La diffusion est mise en evidence par une attaque du film de nitrate, apres exposition, dans de la soude concentree. L'insensibilite de l'enregistreur au rayonnement {beta} {gamma}, emis par l'echantillon apres son sejour en pile, permet d'operer sur de longs temps de pose et de detecter des diffusions faibles. Les courbes concentration - penetration sont etablies par exploitation densitometrique des alphagraphies. - Comme le nitrate de cellulose n'est impressionne que par des particules alpha dont l'energie est

  5. Multinozzle emitter arrays for ultrahigh-throughput nanoelectrospray mass spectrometry

    Science.gov (United States)

    Wang, Daojing; Mao, Pan; Wang, Hung-Ta; Yang, Peidong

    2017-10-17

    The present invention provides for a structure comprising a plurality of emitters, wherein a first nozzle of a first emitter and a second nozzle of a second emitter emit in two directions that are not or essentially not in the same direction; wherein the walls of the nozzles and the emitters form a monolithic whole. The present invention also provides for a structure comprising an emitter with a sharpened end from which the emitter emits; wherein the emitters forms a monolithic whole. The present invention also provides for a fully integrated separation of proteins and small molecules on a silicon chip before the electrospray mass spectrometry analysis.

  6. CEO Compensation and Disclosure Policy

    OpenAIRE

    Zhang, Weijia; Zhang, Kun

    2016-01-01

    This paper examines the relationship between CEO compensation and disclosure policy related to corporate governance information within S&P 500 index. Our sample consists of 456 companies for the period from 2005 to 2015. Most previous researchers mainly put their attention on various corporate governance characteristics such as board size, board independence, and executive ownership when analysing CEO compensation. Our paper extends the previous study by dividing corporate governance into...

  7. Prototype of a subsurface drip irrigation emitter: Manufacturing, hydraulic evaluation and experimental analyses

    Science.gov (United States)

    Souza, Wanderley De Jesus; Rodrigues Sinobas, Leonor; Sánchez, Raúl; Arriel Botrel, Tarlei; Duarte Coelho, Rubens

    2013-04-01

    Root and soil intrusion into the conventional emitters is one of the major disadvantages to obtain a good uniformity of water application in subsurface drip irrigation (SDI). In the last years, there have been different approaches to reduce these problems such as the impregnation of emitters with herbicide, and the search for an emitter geometry impairing the intrusion of small roots. Within the last this study, has developed and evaluated an emitter model which geometry shows specific physical features to prevent emitter clogging. This work was developed at the Biosystems Engineering Department at ESALQ-USP/Brazil, and it is a part of a research in which an innovated emitteŕs model for SDI has been developed to prevent root and soil particles intrusion. An emitter with a mechanical-hydraulic mechanism (opening and closing the water outlet) for SDI was developed and manufactured using a mechanical lathe process. It was composed by a silicon elastic membrane a polyethylene tube and a Vnyl Polychloride membrane protector system. In this study the performance of the developed prototype was assessed in the laboratory and in the field conditions. In the laboratory, uniformity of water application was calculated by the water emission uniformity coefficient (CUE), and the manufacturer's coefficient of variation (CVm). In addition, variation in the membrane diameter submitted to internal pressures; head losses along the membrane, using the energy equation; and, precision and accuracy of the equation model, analyzed by Pearson's correlation coefficient (r), and by Willmott's concordance index (d) were also calculated with samples of the developed emitters. In the field, the emitters were installed in pots with and without sugar cane culture from October 2010 to January 2012. During this time, flow rate in 20 emitters were measured periodically, and the aspects of them about clogging at the end of the experiment. Emitters flow rates were measured quarterly to calculate

  8. The Effect of Compensation Studies on Disadvantaged Children's Self Concept Levels and Locus of Control

    Science.gov (United States)

    Sadioglu, Ömür

    2017-01-01

    The aim of this study is to determine the effect of "Bir Umut Ol Benim Için" (Be My Hope) project which was prepared for the children who were disadvantaged by being influenced from several risk factors as compared to their peers on the self-concepts and locus of controls of the children. The study group consisted of 33 children who were…

  9. Improved cable compensation technique for self powered neutron detectors

    International Nuclear Information System (INIS)

    Nieuwenhove, R. van

    1996-01-01

    Measurements with cobalt self powered neutron detectors on the BR2 reactor have revealed that the currents induced by external gamma radiation can be of the same order as the neutron induced signal and that the gamma induced current on the emitter and the compensator wires are not symmetric. In this case, the standard detection electronic setup leads to erroneous results. It is shown that a slightly modified electronic setup, in which this asymmetry is compensated for, can nevertheless allow to obtain correct neutron flux measurements. Measures to reduce the influence of external gamma radiation in general will also be discussed. (orig.)

  10. Magnetic response in the vicinity of magnetic compensation: a case study in spin ferromagnetic Sm1-xGdxAl2 intermetallic alloys

    International Nuclear Information System (INIS)

    Venkatesh, S; Vaidya, Ulhas; Rakhecha, Veer Chand; Ramakrishnan, S; Grover, A K

    2010-01-01

    A compensated magnetic state in an ideally homogeneous system with long range magnetic order is characterized by a net zero magnetization (M) throughout the sample (macroscopic). In the pristine state of the sample (i.e. with no external field, H = 0), this implies that at the magnetic compensation temperature (T comp ) we must have M = 0 at H = 0 irrespective of any thermal and magnetic history of the sample and any underlying physics. This simple fact voids the usual identification (and interpretation) of M-H loop parameters at and in the vicinity of magnetic compensation temperature, specifically the coercivity, the remanence, and the exchange bias characteristics. The physics of coercivity and exchange bias continues to be fully relevant, but its manifestation in an M-H loop would get camouflaged at (and near) a magnetic compensation because M→0 at H = 0. We present an experimental elucidation of the above premise through a case study in the spin ferromagnetic Sm 1-x Gd x Al 2 alloys [x = 0.01-0.06], where the specimens with x ≤ 0.03 show compensation below the Curie temperature T c , while those with x ≥ 0.03 have rather small magnetization due to near cancellation of opposing contributions, but are otherwise devoid of compensation. The experiments comprised low field (near zero) as well as high field (70 kOe) magnetization measurements from the paramagnetic state down to 5 K in the ordered regime (T c ∼ 125 K) and isothermal M-H loop studies on the remnant magnetic state of polycrystalline samples.

  11. Measurements of Thermal Emittance for Cesium Telluride Photocathodes at PITZ

    CERN Document Server

    Miltchev, V; Grabosch, H J; Han, J H; Krasilnikov, M; Oppelt, A; Petrosian, B; Staykov, L; Stephan, F

    2005-01-01

    The thermal emittance determines the lower emittance limit and its measurement is of high importance to understand the ultimate injector performance. In this contribution we present results of thermal emittance measurements under rf operation conditions for various Cs2Te cathodes and different accelerating gradients. Measurements of thermal emittance scaling with the cathode laser spot size are presented and analysed. The significance of the Schottky effect in the emittance formation process is discussed.

  12. Studies of internal bremsstrahlung spectrum of 35S beta emitter in the photon energy region of 1–100 keV

    International Nuclear Information System (INIS)

    Singh, Amrit; Dhaliwal, A.S.

    2014-01-01

    The internal bremsstrahlung (IB) spectral photon distribution, produced by soft beta particles of 35 S (W max =164 keV), in the photon energy region of 1–100 keV, is measured by using a Si(Li) detector, having high energy resolution and efficiency at low energy region. The measured spectral IB photon distribution is compared with KUB theory and Coulomb corrected IB theories given by Nilsson, and Lewis and Ford. After applying the necessary corrections, the experimental and theoretical IB spectral photon distributions are compared in terms of the number of IB photon of energy k per m o c 2 per unit photon yield. In the low energy region (below 10 keV), the experimental results are in agreement with all the theories. However, in photon energy region of 10–50 keV, experimental results are in agreement with Coulomb corrected Nilsson theory only, within the experimental errors. Further, beyond 50 keV, the Nilsson theory is more close to the experimental results than the KUB, and the Lewis and Ford theories. Hence, the Nilsson theory is more accurate than the other theories given by KUB and Lewis and Ford, particularly at a high energy end. The experimental results reported here with Si(Li) detector are free from number of ambiguities in earlier measurements reported with NaI(Tl) and HPGe detectors. The present results are indicating a relook into the theoretical considerations, given by different theories, while taking into account the Coulomb corrections for predicting the IB spectrum, particularly at high photon energy region. - Highlights: • The internal bremsstrahlung spectrum of 35 S beta emitter, in the photon energy region of 1–100 keV. • These measurement are taken by using a Si(Li) detector. • Theoretical and experimental results are reported in terms of number of photons of energy k per m 0 c 2 per unit photon yield. • The Nilsson theory for IB is more accurate than KUB and Lewis and Ford, particularly at high photon energy region

  13. A low-emittance lattice for SPEAR

    International Nuclear Information System (INIS)

    Safranek, J.; Wiedemann, H.

    1992-01-01

    The design and implementation of a low emittance lattice for the SPEAR storage ring including measurements of the performance of the lattice are presented (J. Safranek, Ph. D. thesis, Stanford University, 1991). The low emittance lattice is designed to optimize the performance of SPEAR as a synchrotron radiation source while keeping SPEAR hardware changes at a minimum. The horizontal emittance of the electron beam in the low emittance lattice is reduced by a factor of 4 from the previous lattice. This reduces the typical horizontal source size and divergence of the photon beams by a factor of 2 each and increases the photon beam brightness. At 3 GeV the horizontal emittance is 129 π nm rad, which makes the low emittance lattice the lowest emittance, runnning synchroton radiation source in the world in the 1.5 to 4.0 GeV energy range for the emittance scaled to 3 GeV. The measured vertical emittance was reduced to half that typically seen at SPEAR in the past. The brightness of the photon beams was further incrased by reducing β y at the insertion devices to 1.1 m and reducing the energy dispersion at the insertion devices by more than a factor of 2 on average. The horizontal despersion at the rf cavities was reduced by a factor of nearly 4 which gives much less problems with synchrobetatron resonances. The dynamic and physical apertures of the lattice are large, giving long beam lifetimes and easy injection of electrons. The measurements of the linear optics and intensity dependent phenomena gave resonable agreement with the design . The overall performance of the machine was very good. Injection rates of 10 to 20 mA/min and larger were achieved routinely, and 100 mA total current was stored. Repeated ramping of stored beam from the injection energy of 2.3 GeV to the running energy of 3.0 GeV was achieved with very little beam loss. This low emittance configuration is expected to be the operating configuration for SPEAR starting in January 1992. (orig.)

  14. Emittance Correction in the 2006 ILC Bunch Compressor

    International Nuclear Information System (INIS)

    Tenenbaum, P.; SLAC

    2007-01-01

    A recent study [1] has indicated substantial potential emittance growth in the ILC bunch compressor due to quad misalignments, BPM misalignments, and pitches in the RF cavities. Table 1 summarizes several results from [1]. In this simulation, quad misalignments and cavity pitches are Gaussian distributed and are considered with respect to the nominal survey line; BPM misalignments are also Gaussian-distributed but are considered with respect to the quadrupole axis. It is assumed that the BPM offsets with respect to the quads are found in a previous quad-shunting BBA step which is not simulated. In this study we seek to repeat the studies documented above, and additionally to perform a study in which additional dispersion bumps are used to further reduce the projected emittance

  15. Filters for stochastic cooling of longitudinal beam emittance

    International Nuclear Information System (INIS)

    Kramer, S.L.; Konecny, R.; Simpson, J.; Wright, A.J.

    1983-03-01

    The shorted stub filter (SSF) has been used extensively to provide the electronics gain shaping for stochastic cooling of longitudinal beam emittance. The repetitive notch of this filter results from the cancellation of the incident signal by the reflected signal at frequencies where the cable electrical length equals an integer number of half wavelengths. Variations in notch depth of the SSF have been approximately compensated by a rather complicated system. Dispersion of the notch frequency resulting from variation of the phase velocity can also be approximately corrected using tuned imperfections in the shorted cable. Dispersion due to imperfections in the coaxial cable can be quite significant and can only be compensated for by costly construction techniques. This paper describes another type of notch filter. Although this filter has been mentioned previously, this analysis demonstrates the advantages of this filter in providing small notch dispersion and other properties necessary for stochastic cooling systems. Because this filter uses only forward signals, it is quite insensitive to imperfections in cables and components, and can therefore be constructed from commercially available components

  16. Space-charge driven emittance growth in a 3D mismatched anisotropic beam

    International Nuclear Information System (INIS)

    Qiang, J.; Ryne, R.D.; Hofmann, I.

    2002-01-01

    In this paper we present a 3D simulation study of the emittance growth in a mismatched anisotropic beam. The equipartitioning driven by a 4th order space-charge resonance can be significantly modified by the presence of mismatch oscillation and halo formation. This causes emittance growth in both the longitudinal and transverse directions which could drive the beam even further away from equipartition. The averaged emittance growth per degree freedom follows the upper bound of the 2D free energy limit plus the contributions from equipartitioning

  17. Common mode noise on the main Tevatron bus and associated beam emittance growth

    International Nuclear Information System (INIS)

    Zhang, P.; Johnson, R.P.; Kuchnir, M.; Siergiej, D.; Wolff, D.

    1991-05-01

    Overlap of betatron tune frequencies with the power supply noise spectrum can cause transverse beam emittance growth in a storage ring. We have studied this effect for tunes near the integer, where the betatron frequency is low. By injecting noise onto the main power supply bus, it was determined that common mode noise was the dominant source of emittance growth. A noise suppression feed-back loop was then used to reduce the noise and the emittance growth. These experiments are described as are investigations of the common mode propagation along the Tevatron bus and measurements of the fields generated by common mode excitation of isolated Tevatron magnets. 3 refs., 4 figs

  18. A Study of Learner-Oriented Negative Emotion Compensation in E-Learning

    Science.gov (United States)

    Qin, Jiwei; Zheng, Qinghua; Li, Haifei

    2014-01-01

    E-learning provides an unprecedented flexibility and convenience for e-learners by breaking the limitations of space and time. However, the role of emotion is neglected in current e-learning systems. We focus strictly on negative emotions of e-learners, integrating emotion regulation theories with recommender technique, and present the study of…

  19. Essays in Executive Compensation

    NARCIS (Netherlands)

    D. Zhang (Dan)

    2012-01-01

    textabstractThis dissertation focuses on how executive compensation is designed and its implications for corporate finance and government regulations. Chapter 2 analyzes several proposals to restrict CEO compensation and calibrates two models of executive compensation that describe how firms would

  20. Long-term follow-up study of compensated low-dose 131I therapy for Graves' disease

    International Nuclear Information System (INIS)

    Sridama, V.; McCormick, M.; Kaplan, E.L.; Fauchet, R.; DeGroot, L.J.

    1984-01-01

    We treated 187 patients who had Graves' disease with low-dose radioactive iodide ( 131 I), using a protocol that included a compensation for thyroid size. The incidence of early hypothyroidism (12 per cent) was acceptably low in the first year after 131 I treatment, but we found a cumulative high incidence (up to 76 per cent) at the end of the 11th year. In contrast, the incidence of permanent hypothyroidism was relatively stable in 166 surgically treated patients, increasing from 19 to 27 per cent at the end of 11 years. Among 122 medically treated patients, only 40 per cent entered remission, and hypothyroidism developed in 2 per cent during the same period of follow-up. The long-term incidence of hypothyroidism in our patients treated with low-dose 131 I therapy was much higher than that found in earlier studies using a comparable dose. Our study suggests that it will be difficult to modify therapy with 131 I alone to produce both early control of thyrotoxicosis and a low incidence of hypothyroidism

  1. Emittance measurement and optimization for the photocathode RF gun with laser profile shaping

    International Nuclear Information System (INIS)

    Liu Shengguang; Masafumi Fukuda; Sakae Araki; Nobuhiro Terunuma; Junji Urakawa

    2010-01-01

    The Laser Undulator Compact X-ray source (LUCX) is a test bench for a compact high brightness X-ray generator, based on inverse Compton Scattering at KEK, which requires high intensity multi-bunch trains with low transverse emittance. A photocathode RF gun with emittance compensation solenoid is used as an electron source. Much endeavor has been made to increase the beam intensity in the multi-bunch trains. The cavity of the RF gun is tuned into an unbalanced field in order to reduce space charge effects, so that the field gradient on the cathode surface is relatively higher when the forward RF power into gun cavity is not high enough. A laser profile shaper is employed to convert the driving laser profile from Gaussian into uniform. In this research we seek to find the optimized operational conditions for the decrease of the transverse emittance. With the uniform driving laser and the unbalanced RF gun, the RMS transverse emittance of a 1 nC bunch has been improved effectively from 5.46 πmm.mrad to 3.66 πmm·mrad. (authors)

  2. Symptomatic cervical disc herniation following a motor vehicle collision: return to work comparative study of workers' compensation versus personal injury insurance status.

    Science.gov (United States)

    Scuderi, Gaetano J; Sherman, Andrew L; Brusovanik, Georgiy V; Pahl, Michael A; Vaccaro, Alexander R

    2005-01-01

    Patients with approved workers' compensation injuries receive guaranteed compensation for the duration of their injury, whereas patients with personal injury claims are only compensated, if at all, at the time of a successful settlement or trial verdict at a time point distant from their injury. This study compares the financial impact and loss of work patterns due to a workers' compensation (WC) claim or personal injury in patients with a symptomatic cervical disc herniation resulting from a motor vehicle collision. A prospective study of patients who were seen by a single spine specialist between 1/2/96 and 9/1/01. A consecutive evaluation of 531 patients who were treated for a cervical pain syndrome caused by a motor vehicle collision. Mechanism of injury and insurance type, ie, workers' compensation or personal injury, was recorded for each patient as well as treatment response and return to work patterns. The data were analyzed using the two-way Z test. All patients were managed in a similar manner with noninvasive treatment initially, followed by injections, and finally surgical intervention in those who failed conservative measures. Return to work rates and work disability were determined at either final follow-up or at the last doctor's visit before loss to follow-up. 270 of 531 patients were diagnosed with a symptomatic one or two level disc herniation by a cervical magnetic resonance imaging scan. Fifty-four patients were insured through the workers' compensation board, and 216 reported their crash as a personal injury claim. In the WC group the work disability at 3 months follow-up revealed a cumulative 2,262 total lost days of work (average 37.1 days per person). At the point of maximal medical improvement (MMI) or 2-year follow-up, total days lost from work were 7,107 (average 131.6 days per person.) In the personal injury non-WC group, the 3-month follow-up of lost days of work was 1,093 days (average 5.1 days per person.) At 2 years follow-up, the

  3. Generalized superradiant assembly for nanophotonic thermal emitters

    Science.gov (United States)

    Mallawaarachchi, Sudaraka; Gunapala, Sarath D.; Stockman, Mark I.; Premaratne, Malin

    2018-03-01

    Superradiance explains the collective enhancement of emission, observed when nanophotonic emitters are arranged within subwavelength proximity and perfect symmetry. Thermal superradiant emitter assemblies with variable photon far-field coupling rates are known to be capable of outperforming their conventional, nonsuperradiant counterparts. However, due to the inability to account for assemblies comprising emitters with various materials and dimensional configurations, existing thermal superradiant models are inadequate and incongruent. In this paper, a generalized thermal superradiant assembly for nanophotonic emitters is developed from first principles. Spectral analysis shows that not only does the proposed model outperform existing models in power delivery, but also portrays unforeseen and startling characteristics during emission. These electromagnetically induced transparency like (EIT-like) and superscattering-like characteristics are reported here for a superradiant assembly, and the effects escalate as the emitters become increasingly disparate. The fact that the EIT-like characteristics are in close agreement with a recent experimental observation involving the superradiant decay of qubits strongly bolsters the validity of the proposed model.

  4. Diamond-based single-photon emitters

    International Nuclear Information System (INIS)

    Aharonovich, I; Castelletto, S; Simpson, D A; Su, C-H; Greentree, A D; Prawer, S

    2011-01-01

    The exploitation of emerging quantum technologies requires efficient fabrication of key building blocks. Sources of single photons are extremely important across many applications as they can serve as vectors for quantum information-thereby allowing long-range (perhaps even global-scale) quantum states to be made and manipulated for tasks such as quantum communication or distributed quantum computation. At the single-emitter level, quantum sources also afford new possibilities in terms of nanoscopy and bio-marking. Color centers in diamond are prominent candidates to generate and manipulate quantum states of light, as they are a photostable solid-state source of single photons at room temperature. In this review, we discuss the state of the art of diamond-based single-photon emitters and highlight their fabrication methodologies. We present the experimental techniques used to characterize the quantum emitters and discuss their photophysical properties. We outline a number of applications including quantum key distribution, bio-marking and sub-diffraction imaging, where diamond-based single emitters are playing a crucial role. We conclude with a discussion of the main challenges and perspectives for employing diamond emitters in quantum information processing.

  5. Electron field emission characteristics of graphene/carbon nanotubes hybrid field emitter

    International Nuclear Information System (INIS)

    Chen, Leifeng; He, Hong; Yu, Hua; Cao, Yiqi; Lei, Da; Menggen, QiQiGe; Wu, Chaoxing; Hu, Liqin

    2014-01-01

    The graphene (GP) and multi-walled carbon nanotubes (MCNTs) hybrid nanostructure emitter was constructed by a larger scale electrophoretic deposition (EPD) method. The field emission (FE) performance of the hybrid emitter is greatly improved compared with that of only GP or MCNTs emitter. The low turn-on electric field (EF), the low threshold EF and the reliability FE properties are obtained from the hybrid emitter. The better FE properties result from the improved electrical properties. For further enhancement FE of hybrids, Ag Nanoparticles (NPs) were decorated on the hybrids and FE characteristics were also studied. These studies indicate that we can use the hybrid nanostructure to improve conductivity and contact resistance, which results in enhancement of the FE properties

  6. Generation of low-emittance electron beams in electrostatic accelerators for FEL applications

    Science.gov (United States)

    Teng, Chen; Elias, Luis R.

    1995-02-01

    This paper reports results of transverse emittance studies and beam propagation in electrostatic accelerators for free electron laser applications. In particular, we discuss emittance growth analysis of a low current electron beam system consisting of a miniature thermoionic electron gun and a National Electrostatics Accelerator (NEC) tube. The emittance growth phenomenon is discussed in terms of thermal effects in the electron gun cathode and aberrations produced by field gradient changes occurring inside the electron gun and throughout the accelerator tube. A method of reducing aberrations using a magnetic solenoidal field is described. Analysis of electron beam emittance was done with the EGUN code. Beam propagation along the accelerator tube was studied using a cylindrically symmetric beam envelope equation that included beam self-fields and the external accelerator fields which were derived from POISSON simulations.

  7. Generation of low-emittance electron beams in electrostatic accelerators for FEL applications

    International Nuclear Information System (INIS)

    Chen Teng; Central Florida Univ., Orlando, FL; Elias, L.R. R.; Central Florida Univ., Orlando, FL

    1995-01-01

    This paper reports results of transverse emittance studies and beam propagation in electrostatic accelerators for free electron laser applications. In particular, we discuss emittance growth analysis of a low current electron beam system consisting of a miniature thermoionic electron gun and a National Electrostatics Accelerator (NEC) tube. The emittance growth phenomenon is discussed in terms of thermal effects in the electron gun cathode and aberrations produced by field gradient changes occurring inside the electron gun and throughout the accelerator tube. A method of reducing aberrations using a magnetic solenoidal field is described. Analysis of electron beam emittance was done with the EGUN code. Beam propagation along the accelerator tube was studied using a cylindrically symmetric beam envelope equation that included beam self-fields and the external accelerator fields which were derived from POISSON simulations. ((orig.))

  8. Generation of low-emittance electron beams in electrostatic accelerators for FEL applications

    Energy Technology Data Exchange (ETDEWEB)

    Chen Teng [University of Central Florida, Orlando, FL (United States). Center for Research in Electro-Optics and Lasers (CREOL)]|[Central Florida Univ., Orlando, FL (United States). Dept. of Physics; Elias, L.R. R. [University of Central Florida, Orlando, FL (United States). Center for Research in Electro-Optics and Lasers (CREOL)]|[Central Florida Univ., Orlando, FL (United States). Dept. of Physics

    1995-01-30

    This paper reports results of transverse emittance studies and beam propagation in electrostatic accelerators for free electron laser applications. In particular, we discuss emittance growth analysis of a low current electron beam system consisting of a miniature thermoionic electron gun and a National Electrostatics Accelerator (NEC) tube. The emittance growth phenomenon is discussed in terms of thermal effects in the electron gun cathode and aberrations produced by field gradient changes occurring inside the electron gun and throughout the accelerator tube. A method of reducing aberrations using a magnetic solenoidal field is described. Analysis of electron beam emittance was done with the EGUN code. Beam propagation along the accelerator tube was studied using a cylindrically symmetric beam envelope equation that included beam self-fields and the external accelerator fields which were derived from POISSON simulations. ((orig.))

  9. Chromosome X-wide association study identifies Loci for fasting insulin and height and evidence for incomplete dosage compensation.

    Science.gov (United States)

    Tukiainen, Taru; Pirinen, Matti; Sarin, Antti-Pekka; Ladenvall, Claes; Kettunen, Johannes; Lehtimäki, Terho; Lokki, Marja-Liisa; Perola, Markus; Sinisalo, Juha; Vlachopoulou, Efthymia; Eriksson, Johan G; Groop, Leif; Jula, Antti; Järvelin, Marjo-Riitta; Raitakari, Olli T; Salomaa, Veikko; Ripatti, Samuli

    2014-02-01

    The X chromosome (chrX) represents one potential source for the "missing heritability" for complex phenotypes, which thus far has remained underanalyzed in genome-wide association studies (GWAS). Here we demonstrate the benefits of including chrX in GWAS by assessing the contribution of 404,862 chrX SNPs to levels of twelve commonly studied cardiometabolic and anthropometric traits in 19,697 Finnish and Swedish individuals with replication data on 5,032 additional Finns. By using a linear mixed model, we estimate that on average 2.6% of the additive genetic variance in these twelve traits is attributable to chrX, this being in proportion to the number of SNPs in the chromosome. In a chrX-wide association analysis, we identify three novel loci: two for height (rs182838724 near FGF16/ATRX/MAGT1, joint P-value = 2.71×10(-9), and rs1751138 near ITM2A, P-value = 3.03×10(-10)) and one for fasting insulin (rs139163435 in Xq23, P-value = 5.18×10(-9)). Further, we find that effect sizes for variants near ITM2A, a gene implicated in cartilage development, show evidence for a lack of dosage compensation. This observation is further supported by a sex-difference in ITM2A expression in whole blood (P-value = 0.00251), and is also in agreement with a previous report showing ITM2A escapes from X chromosome inactivation (XCI) in the majority of women. Hence, our results show one of the first links between phenotypic variation in a population sample and an XCI-escaping locus and pinpoint ITM2A as a potential contributor to the sexual dimorphism in height. In conclusion, our study provides a clear motivation for including chrX in large-scale genetic studies of complex diseases and traits.

  10. Low emittance optics of photon factory storage ring at KEK

    International Nuclear Information System (INIS)

    Kamiya, Y.; Katoh, M.; Honjo, I.; Araki, A.; Kihara, M.

    1987-01-01

    A new optics is being successfully tested at the Photon Factory Storage Ring (PF-RING) in order to reduce the emittance to 0.13 mm mrad, about one third of the present value. This optics with four additional quadrupole magnets is a modified version of one of the optics designed as an option at the early period of PF construction. One advantage of this new optics is that the beta-function at RF-sections is smaller than that of the old option. The other advantage is that the dispersion function is zero at the long straight sections for insertion devices and RF cavities. The aim of this paper is to describe the new low-emittance optics as well as the parameters of the new quadrupole magnets and power supplies. Some preliminary results of machine study are also presented

  11. Tellurium adsorption on tungsten and molybdenum field emitters

    International Nuclear Information System (INIS)

    Collins, R.A.; Kiwanga, C.A.

    1977-01-01

    Studies of the adsorption of tellurium onto tungsten and molybdenum field emitters are described and the results obtained are compared with those obtained in previous work on the adsorption of silicon and selenium. The adsorption of Te onto W was found to be much more uniform than in the case of Se. Although Te is metallic in many of its properties its adsorptive behavior on field emitters is found to be similar to that of selenium and these adsorptive properties are basically common to all semiconductors. The most evident property of these adsorbates is that the work function and emission current decrease simultaneously at coverages of less than half a monolayer and the work function subsequently increases. (B.D.)

  12. Emittance growth in non-symmetric beam configurations

    International Nuclear Information System (INIS)

    Anderson, O.A.

    1996-06-01

    Emittance growth in intense beams due to nonuniformity, mismatch, and misalignment has been analyzed by Reiser for the special case of axisymmetry. A more complex problem occurs in cases where a number of discrete beamlets are to be merged into a single focusing channel, for example, in designs for Heavy Ion Fusion drivers or Magnetic Fusion negative-ion systems. Celata, assuming the system to be perfectly matched and aligned, analyzed the case of four round beamlets arranged in a square array. We generalize these previous studies and analyze emittance growth in systems that are less symmetric. We include beam systems that are not necessarily matched and where the x and y moments may be unequal. We also include the possibility of initial convergence velocities that may differ in the two planes and allow for misalignment of the beam center-of-mass position and direction

  13. BEAM EMITTANCE MEASUREMENT TOOL FOR CEBAF OPERATIONS

    International Nuclear Information System (INIS)

    Chevtsov, Pavel; Tiefenback, Michael

    2008-01-01

    A new software tool was created at Jefferson Lab to measure the emittance of the CEBAF electron beams. The tool consists of device control and data analysis applications. The device control application handles the work of wire scanners and writes their measurement results as well as the information about accelerator settings during these measurements into wire scanner data files. The data analysis application reads these files and calculates the beam emittance on the basis of a wire scanner data processing model. Both applications are computer platform independent but are mostly used on LINUX PCs recently installed in the accelerator control room. The new tool significantly simplifies beam emittance measurement procedures for accelerator operations and contributes to a very high availability of the CEBAF machine for the nuclear physics program at Jefferson Lab.

  14. Solid-state single-photon emitters

    Science.gov (United States)

    Aharonovich, Igor; Englund, Dirk; Toth, Milos

    2016-10-01

    Single-photon emitters play an important role in many leading quantum technologies. There is still no 'ideal' on-demand single-photon emitter, but a plethora of promising material systems have been developed, and several have transitioned from proof-of-concept to engineering efforts with steadily improving performance. Here, we review recent progress in the race towards true single-photon emitters required for a range of quantum information processing applications. We focus on solid-state systems including quantum dots, defects in solids, two-dimensional hosts and carbon nanotubes, as these are well positioned to benefit from recent breakthroughs in nanofabrication and materials growth techniques. We consider the main challenges and key advantages of each platform, with a focus on scalable on-chip integration and fabrication of identical sources on photonic circuits.

  15. Emittance Measurement for Beamline Extension at the PET Cyclotron

    Directory of Open Access Journals (Sweden)

    Sae-Hoon Park

    2016-01-01

    Full Text Available Particle-induced X-ray emission is used for determining the elemental composition of materials. This method uses low-energy protons (of several MeV, which can be obtained from high-energy (of tens MeV accelerators. Instead of manufacturing an accelerator for generating the MeV protons, the use of a PET cyclotron has been suggested for designing the beamline for multipurpose applications, especially for the PIXE experiment, which has a dedicated high-energy (of tens MeV accelerator. The beam properties of the cyclotron were determined at this experimental facility by using an external beamline before transferring the ion beam to the experimental chamber. We measured the beam profile and calculated the emittance using the pepper-pot method. The beam profile was measured as the beam current using a wire scanner, and the emittance was measured as the beam distribution at the beam dump using a radiochromic film. We analyzed the measurement results and are planning to use the results obtained in the simulations of external beamline and aligned beamline components. We will consider energy degradation after computing the beamline simulation. The experimental study focused on measuring the emittance from the cyclotron, and the results of this study are presented in this paper.

  16. Shaping the electron beams with submicrosecond pulse duration in sources and electron accelerators with plasma emitters

    CERN Document Server

    Gushenets, V I

    2001-01-01

    One studies the techniques in use to shape submicrosecond electron beams and the physical processes associated with extraction of electrons from plasma in plasma emitters. Plasma emitter base sources and accelerators enable to generate pulse beams with currents varying from tens of amperes up to 10 sup 3 A, with current densities up to several amperes per a square centimeter, with pulse duration constituting hundreds of nanoseconds and with high frequencies of repetition

  17. Low emittance lattice optimization using a multi-objective evolutionary algorithm

    International Nuclear Information System (INIS)

    Gao Weiwei; Wang Lin; Li Weimin; He Duohui

    2011-01-01

    A low emittance lattice design and optimization procedure are systematically studied with a non-dominated sorting-based multi-objective evolutionary algorithm which not only globally searches the low emittance lattice, but also optimizes some beam quantities such as betatron tunes, momentum compaction factor and dispersion function simultaneously. In this paper the detailed algorithm and lattice design procedure are presented. The Hefei light source upgrade project storage ring lattice, with fixed magnet layout, is designed to illustrate this optimization procedure. (authors)

  18. Prevalence and compensation of academic leaders, professors, and trustees on publicly traded US healthcare company boards of directors: cross sectional study.

    Science.gov (United States)

    Anderson, Timothy S; Good, Chester B; Gellad, Walid F

    2015-09-29

    To identify the prevalence, characteristics, and compensation of members of the boards of directors of healthcare industry companies who hold academic appointments as leaders, professors, or trustees. Cross sectional study. US healthcare companies publicly traded on the NASDAQ or New York Stock Exchange in 2013. 3434 directors of pharmaceutical, biotechnology, medical equipment and supply, and healthcare provider companies. Prevalence, annual compensation, and beneficial stock ownership of directors with affiliations as leaders, professors, or trustees of academic medical and research institutions. 446 healthcare companies met the study search criteria, of which 442 (99%) had publicly accessible disclosures on boards of directors. 180 companies (41%) had one or more academically affiliated directors. Directors were affiliated with 85 geographically diverse non-profit academic institutions, including 19 of the top 20 National Institute of Health funded medical schools and all of the 17 US News honor roll hospitals. Overall, these 279 academically affiliated directors included 73 leaders, 121 professors, and 85 trustees. Leaders included 17 chief executive officers and 11 vice presidents or executive officers of health systems and hospitals; 15 university presidents, provosts, and chancellors; and eight medical school deans or presidents. The total annual compensation to academically affiliated directors for their services to companies was $54,995,786 (£35,836,000; €49,185,900) (median individual compensation $193,000) and directors beneficially owned 59,831,477 shares of company stock (median 50,699 shares). A substantial number and diversity of academic leaders, professors, and trustees hold directorships at US healthcare companies, with compensation often approaching or surpassing common academic clinical salaries. Dual obligations to for profit company shareholders and non-profit clinical and educational institutions pose considerable personal, financial, and

  19. MD2065: Emittance exchange with linear coupling

    CERN Document Server

    Carver, Lee Robert; Persson, Tobias Hakan Bjorn; Amorim, David; Levens, Tom; Pesah, Arthur Chalom; CERN. Geneva. ATS Department

    2018-01-01

    In order to better understand the luminosity imbalance between ATLAS and CMS that was observed in 2016, it was proposed to perform a test whereby the horizontal and vertical emittances are exchanged by crossing the tunes in the presence of linear coupling. The luminosity before and after the exchange could be compared to see if the imbalance stems purely from the uneven emittances or if there is an additional mechanism in play. However, due to limited machine availability only tests at injection were able to performed.

  20. Minimum emittance of three-bend achromats

    International Nuclear Information System (INIS)

    Li Xiaoyu; Xu Gang

    2012-01-01

    The calculation of the minimum emittance of three-bend achromats (TBAs) made by Mathematical software can ignore the actual magnets lattice in the matching condition of dispersion function in phase space. The minimum scaling factors of two kinds of widely used TBA lattices are obtained. Then the relationship between the lengths and the radii of the three dipoles in TBA is obtained and so is the minimum scaling factor, when the TBA lattice achieves its minimum emittance. The procedure of analysis and the results can be widely used in achromats lattices, because the calculation is not restricted by the actual lattice. (authors)

  1. Quadrupole Transfer Function for Emittance Measurement

    CERN Document Server

    Cameron, Peter; Jansson, Andreas; Tan, Cheng-Yang

    2008-01-01

    Historically the use of the quadrupole moment measurement has been impeded by the requirement for large dynamic range, as well as measurement sensitivity to beam position. We investigate the use of the transfer function technique [1-3] in combination with the sensitivity and 160dB revolution line rejection of the direct diode detection analog front end [4] to open the possibility of an emittance diagnostic that may be implemented without operational complication, quasi- parasitic to the operation of existing tune measurement systems. Such a diagnostic would be particularly useful as an emittance monitor during acceleration ramp development in machines like RHIC and the LHC.

  2. An investigation of models of rhodium emitter used in self-powered neutron detector

    International Nuclear Information System (INIS)

    Borisenko, V.I.; Piontkovskij, Yu.F.; Goranchuk, V.V.

    2017-01-01

    he paper presents the results of MCNP simulation of the self-powered neutron detector (SPND) signal formation as a result of emitter nuclei activation under the irradiation with neutrons generated in the fuel assemblies. To account for the non-uniformity of emitter burnup along the radius, its model was divided radially into 10 layers of equal thickness. It has been shown that the main contribution of about 88 % of SPND signal is provided by the four peripheral emitter layers. The contribution of different parts of emitter to the SPND signal formation throughout the lifetime of the SPND in the In-Core Monitoring System was found. Simulation results allow us to determine the SPND signal when the spectral characteristics of the neutron flux at the detector location change during the fuel campaign. The study has investigated and proposed a SPND model with the higher neutron sensitivity even though a smaller amount of expensive rhodium is used.

  3. Room-temperature deposition of diamond-like carbon field emitter on flexible substrates

    International Nuclear Information System (INIS)

    Chen, H.; Iliev, M.N.; Liu, J.R.; Ma, K.B.; Chu, W.-K.; Badi, N.; Bensaoula, A.; Svedberg, E.B.

    2006-01-01

    Room-temperature fabrication of diamond-like carbon electron field emitters on flexible polyimide substrate is reported. These thin film field emitters are made using an Ar gas cluster ion beam assisted C 6 vapor deposition method. The bond structure of the as-deposited diamond-like carbon film was studied using Raman spectroscopy. The field emission characteristics of the deposited films were also measured. Electron current densities over 15 mA/cm 2 have been recorded under an electrical field of about 65 V/μm. These diamond-like carbon field emitters are easy and inexpensive to fabricate. The results are promising for flexible field-emission fabrication without the need of complex patterning and tip shaping as compared to the Spindt-type field emitters

  4. CT-based attenuation correction and resolution compensation for I-123 IMP brain SPECT normal database: a multicenter phantom study.

    Science.gov (United States)

    Inui, Yoshitaka; Ichihara, Takashi; Uno, Masaki; Ishiguro, Masanobu; Ito, Kengo; Kato, Katsuhiko; Sakuma, Hajime; Okazawa, Hidehiko; Toyama, Hiroshi

    2018-03-19

    Statistical image analysis of brain SPECT images has improved diagnostic accuracy for brain disorders. However, the results of statistical analysis vary depending on the institution even when they use a common normal database (NDB), due to different intrinsic spatial resolutions or correction methods. The present study aimed to evaluate the correction of spatial resolution differences between equipment and examine the differences in skull bone attenuation to construct a common NDB for use in multicenter settings. The proposed acquisition and processing protocols were those routinely used at each participating center with additional triple energy window (TEW) scatter correction (SC) and computed tomography (CT) based attenuation correction (CTAC). A multicenter phantom study was conducted on six imaging systems in five centers, with either single photon emission computed tomography (SPECT) or SPECT/CT, and two brain phantoms. The gray/white matter I-123 activity ratio in the brain phantoms was 4, and they were enclosed in either an artificial adult male skull, 1300 Hounsfield units (HU), a female skull, 850 HU, or an acrylic cover. The cut-off frequency of the Butterworth filters was adjusted so that the spatial resolution was unified to a 17.9 mm full width at half maximum (FWHM), that of the lowest resolution system. The gray-to-white matter count ratios were measured from SPECT images and compared with the actual activity ratio. In addition, mean, standard deviation and coefficient of variation images were calculated after normalization and anatomical standardization to evaluate the variability of the NDB. The gray-to-white matter count ratio error without SC and attenuation correction (AC) was significantly larger for higher bone densities (p correction. The proposed protocol showed potential for constructing an appropriate common NDB from SPECT images with SC, AC and spatial resolution compensation.

  5. Investigations on the transverse phase space at a photo injector for minimized emittance

    Energy Technology Data Exchange (ETDEWEB)

    Miltchev, V.

    2006-08-15

    Radio frequency photoinjectors are electron sources able to generate beams of extremely high brightness, which are applicable to linac driven Free Electron Lasers (FEL). Because of the high phase space density, the dynamics of the electron beam is dominated by space charge interactions between the particles. This thesis studies the transverse phase space of space charge dominated electron beams produced by the Photo Injector Test Facility in Zeuthen (PITZ). The operation conditions for minimizing the transverse emittance are studied experimentally, theoretically and in simulations. The influence of the longitudinal profile of the driving UV laser pulse on the transverse emittance is investigated. Emphasis is placed on the experimental study of the emittance as a function of different machine parameters like the laser beam spot size, the amplitude of the focusing magnetic field, the rf phase and the electron bunch charge. First investigations on the thermal emittance for Cs{sub 2}Te photocathodes under rf operating conditions are presented. Measurements of the thermal emittance scaling with the photocathode laser spot size are analyzed. The significance of the applied rf field in the emittance formation process is discussed. (orig.)

  6. Investigations on the transverse phase space at a photo injector for minimized emittance

    International Nuclear Information System (INIS)

    Miltchev, V.

    2006-08-01

    Radio frequency photoinjectors are electron sources able to generate beams of extremely high brightness, which are applicable to linac driven Free Electron Lasers (FEL). Because of the high phase space density, the dynamics of the electron beam is dominated by space charge interactions between the particles. This thesis studies the transverse phase space of space charge dominated electron beams produced by the Photo Injector Test Facility in Zeuthen (PITZ). The operation conditions for minimizing the transverse emittance are studied experimentally, theoretically and in simulations. The influence of the longitudinal profile of the driving UV laser pulse on the transverse emittance is investigated. Emphasis is placed on the experimental study of the emittance as a function of different machine parameters like the laser beam spot size, the amplitude of the focusing magnetic field, the rf phase and the electron bunch charge. First investigations on the thermal emittance for Cs 2 Te photocathodes under rf operating conditions are presented. Measurements of the thermal emittance scaling with the photocathode laser spot size are analyzed. The significance of the applied rf field in the emittance formation process is discussed. (orig.)

  7. Emittance scans for CMS luminosity calibration in 2017

    CERN Document Server

    CMS Collaboration

    2018-01-01

    Emittance scans are short van der Meer type scans performed at the beginning and at the end of LHC fills. The beams are scanned against each other in X and Y planes in 7 displacement steps. These scans are used for LHC diagnostics and since 2017 for a cross check of the CMS luminosity calibration. An XY pair of scans takes around 3 minutes. The BRIL project provides to LHC three independent online luminosity measurement from the Pixel Luminosity Telescope (PLT), the Fast Beam Condition Monitor (BCM1F) and the Forward calorimeter (HF). The excellent performance of the BRIL detector front-ends, fast back-end electronics and CMS XDAQ based data processing and publication allow the use of emittance scans for linearity and stability studies of the luminometers. Emittance scans became a powerful tool and dramatically improved the understanding of the luminosity measurement during the year. Since each luminometer is independently calibrated in every scan the measurements are independent and ratios of luminometers ca...

  8. 1024x1024 resistive emitter array design and fabrication status

    Science.gov (United States)

    Bryant, Paul T.; Oleson, Jim; McHugh, Stephen W.; Beuville, Eric; Schlesselmann, John D.; Woolaway, James T.; Barskey, Steve; Solomon, Steven L.; Joyner, Thomas W.

    2002-07-01

    Santa Barbara Infrared (SBIR) is producing a high performance 1,024 x 1,024 Large Format Resistive emitter Array (LFRA) for use in the next generation of IR Scene Projectors (IRSPs). LFRA requirements were developed through close cooperation with the Tri-Service IR Scene Projector working group, and through detailed trade studies sponsored by the OSD Central T&E Investment Program (CTEIP) and a Phase I US Navy Small Business Innovative Research (SBIR) contract. The CMOS Read-In Integrated Circuit (RIIC) is being designed by SBIR and Indigo Systems under a Small Business Innovative Research (SBIR) contract. Performance and features include 750 K MWIR maximum apparent temperature, 5 ms radiance rise time, 200 Hz full frame update, and 400 Hz window mode operation. Ten 8-inch CMOS wafers will be fabricated and characterized in mid-2002, followed by emitter fabrication in late 2002. This paper discusses array performance, requirements flow-down, array design, fabrication of 2 X 2-inch CMOS devices, and plans for subsequent RIIC wafer test and emitter pixel fabrication.

  9. Fowler Nordheim theory of carbon nanotube based field emitters

    Energy Technology Data Exchange (ETDEWEB)

    Parveen, Shama; Kumar, Avshish [Department of Physics, Jamia Millia Islamia (Central University), New Delhi (India); Husain, Samina [Centre for Nanoscience and Nanotechnology, Jamia Millia Islamia (Central University), New Delhi (India); Husain, Mushahid, E-mail: mush_reslab@rediffmail.com [Department of Physics, Jamia Millia Islamia (Central University), New Delhi (India)

    2017-01-15

    Field emission (FE) phenomena are generally explained in the frame-work of Fowler Nordheim (FN) theory which was given for flat metal surfaces. In this work, an effort has been made to present the field emission mechanism in carbon nanotubes (CNTs) which have tip type geometry at nanoscale. High aspect ratio of CNTs leads to large field enhancement factor and lower operating voltages because the electric field strength in the vicinity of the nanotubes tip can be enhanced by thousand times. The work function of nanostructure by using FN plot has been calculated with reverse engineering. With the help of modified FN equation, an important formula for effective emitting area (active area for emission of electrons) has been derived and employed to calculate the active emitting area for CNT field emitters. Therefore, it is of great interest to present a state of art study on the complete solution of FN equation for CNTs based field emitter displays. This manuscript will also provide a better understanding of calculation of different FE parameters of CNTs field emitters using FN equation.

  10. Disparate compensation policies for research related injury in an era of multinational trials: a case study of Brazil, Russia, India, China and South Africa.

    Science.gov (United States)

    Chingarande, George Rugare; Moodley, Keymanthri

    2018-02-17

    Compensation for research related injuries is a subject that is increasingly gaining traction in developing countries which are burgeoning destinations of multi center research. However, the existence of disparate compensation rules violates the ethical principle of fairness. The current paper presents a comparison of the policies of Brazil, Russia, India, China and South Africa (BRICS). A systematic search of good clinical practice guidelines was conducted employing search strategies modeled in line with the recommendations of ADPTE Collaboration (2007). The search focused on three main areas namely bibliographic data bases, clinical practice guidelines data bases and a restricted internet search. A manual search of references cited in relevant guideline documents was also conducted. The search terms, Medical Subject Headings (MeSH) and key words were developed for a PubMed platform and then adapted for all other data bases. The search terms were kept constant for each country with the only difference being the country name. The documents so obtained were subjected to systematic content analysis. The study revealed that there is vast panoply of regulations which exist on a continuum. On one extreme is India with comprehensive regulations that are codified into law, and on the other end there is China which does not have specific laws regulating research related injuries. There are a number of differences and similarities such as mandatory insurance requirements, existence of no fault compensation, compensable injuries and the role of research ethics committees. It is imperative to enact legislations that protect participants without stifling the research enterprise. There is need for consistency and ideally harmonization of such regulations at a global level. A model policy on compensation for research related injuries should borrow from the best aspects of the different country policies and should be informed by the cardinal ethics principles of autonomy, justice

  11. High emittance black nickel coating on copper substrate for space applications

    Energy Technology Data Exchange (ETDEWEB)

    Somasundaram, Soniya, E-mail: jrf0013@isac.gov.in; Pillai, Anju M., E-mail: anjum@isac.gov.in; Rajendra, A., E-mail: rajendra@isac.gov.in; Sharma, A.K., E-mail: aks@isac.gov.in

    2015-09-15

    Highlights: • High emittance black nickel coating is obtained on copper substrate. • The effect of various process parameters on IR emittance is studied systematically. • Process parameters are optimized to develop a high emittance black nickel coating. • Coating obtained using the finalized parameters exhibited an emittance of 0.83. • SEM and EDAX are used for coating characterization. - Abstract: Black nickel, an alloy coating of zinc and nickel, is obtained on copper substrate by pulse electrodeposition from a modified Fishlock bath containing nickel sulphate, nickel ammonium sulphate, zinc sulphate and ammonium thiocyanate. A nickel undercoat of 4–5 μm thickness is obtained using Watts bath to increase the corrosion resistance and adhesion of the black nickel coating. The effect of bath composition, temperature, solution pH, current density and plating time on the coating appearance and corresponding infra-red emittance of the coating is investigated systematically. Process parameters are optimized to develop a high emittance space worthy black nickel coating to improve the heat radiation characteristics. The effect of the chemistry of the plating bath on the coating composition was studied using energy dispersive X-ray analysis (EDAX) of the coatings. The 5–6 μm thick uniform jet black zinc–nickel alloy coating obtained with optimized process exhibited an emittance of 0.83 and an absorbance of 0.92. The zinc to nickel ratio of black nickel coatings showing high emittance and appealing appearance was found to be in the range 2.3–2.4.

  12. Developing fair compensation structures

    International Nuclear Information System (INIS)

    Trousdale, W.J.

    1998-01-01

    The issue of finding an effective way to incorporate Aboriginal values into the process of developing fair compensation structures was discussed. This paper discusses pricing intangible values using dollars, but it was emphasized that 'values' are whatever are important to us. Therefore, in order to achieve fair compensation, creative alternatives that are value-focused should be pursued. In addition to the more straight-forward monetary compensation, compensation could also be about avoiding losses, mitigating adverse impacts, achieving better communication, and promoting cultural understanding. 25 refs., 2 tabs

  13. A low emittance configuration for spear

    International Nuclear Information System (INIS)

    Blumberg, L.N.; Cerino, J.; Harris, J.; Hettel, R.; Hofmann, A.; Liu, R.Z.; Stego, R.; Wiedemann, H.; Winick, H.

    1985-01-01

    The quality of synchrotron radiation beams from SPEAR, in particular the brilliance of undulator radiation, can be improved significantly by reducing the emittance of the stored electron beam. A reduction of the horizontal emittance by a factor of 3.5 to a value of 130 nanometer-radians (nm-r) at 3 GeV has been achieved by using stronger focussing, mainly in the horizontal plane. The low emittance configuration also reduces the dispersion and vertical beta functions in the straight sections, making them more suitable for wigglers. The higher betatron tunes lead to a larger phase advance between the two kickers, which has to be corrected during injection by shunting current from some quadrupoles. The configuration was optimized within SPEAR hardware limitations and tested for dynamic aperture with the tracking program PATRICIA. After implementation of this scheme, beam was successfully injected and accumulated. The measured emittance of the stored beam was in agreement with calculations. Presently the configuration is being made operational

  14. Simple-to-prepare multipoint field emitter

    Science.gov (United States)

    Sominskii, G. G.; Taradaev, E. P.; Tumareva, T. A.; Mishin, M. V.; Kornishin, S. Yu.

    2015-07-01

    We investigate multitip field emitters prepared by electroerosion treatment of the surface of molybdenum samples. Their characteristics are determined for operation with a protecting activated fullerene coating. Our experiments indicate that such cathodes are promising for high-voltage electron devices operating in technical vacuum.

  15. Emittance measuring system on the UNILAC

    International Nuclear Information System (INIS)

    Ehrich, A.; Glatz, J.; Strahl, P.

    A description is given of one of the beam emittance measuring systems designed for the UNILAC at GSI. The measuring system mechanics and the detector system are detailed, and the associated electronics are discussed. Computer programming and data processing and evaluation are described

  16. Aluminum oxide film thickness and emittance

    International Nuclear Information System (INIS)

    Thomas, J.K.; Ondrejcin, R.S.

    1991-11-01

    Aluminum reactor components which are not actively cooled could be subjected to high temperatures due to gamma heating after the core coolant level dropped during the ECS phase of a hypothetical LOCA event. Radiative heat transfer is the dominant heat transfer process in this scenario and therefore the emittance of these components is of interest. Of particular interest are the safety rod thimbles and Mark 60B blanket assemblies; for the K Reactor, these components have been exposed to low temperature (< 55 degrees C) moderator for about a year. The average moderator temperature was assumed to be 30 degrees C. The Al oxide film thickness at this temperature, after one year of exposure, is predicted to be 6.4 μm ± 10%; insensitive to exposure time. Dehydration of the film during the gamma heating accident would result in a film thickness of 6.0 μm ± 11%. Total hemispherical emittance is predicted to be 0.69 at 96 degrees C, decreasing to 0.45 at 600 degrees C. Some phenomena which would tend to yield thicker oxide films in the reactor environment relative to those obtained under experimental conditions were neglected and the predicted film thickness values are therefore conservative. The emittance values predicted for a given film thickness are also conservative. The conservativisms inherent in the predicted emittance are particularly relevant for uncertainty analysis of temperatures generated using these values

  17. Low Cost Constant – Head Drip Irrigation Emitter for Climate ...

    African Journals Online (AJOL)

    Low Cost Constant – Head Drip Irrigation Emitter for Climate Change Adaptation in Nigeria: Engineering Design and Calibration. ... The drip system comprises of abarrel, sub-main line, lateral lines, tubes and emitters, it can irrigate140 crop ...

  18. Acceleration, current amplification and emittance in MBE-4, an experimental beam induction linear accelerator for heavy ions

    International Nuclear Information System (INIS)

    Warwick, A.I.; Gough, D.E.; Keefe, D.; Meuth, H.

    1988-10-01

    We report on the implementation of a second schedule of acceleration and current amplification in MBE-4. Control of the beam current within the bunch is improved over that in the first schedule by the addition of several small amplitude induction pulsers to compensate for acceleration errors and to control the ends of the bunch. Measurements of the longitudinal and transverse emittance are presented. 5 refs., 3 figs., 1 tab

  19. Acceleration, current amplification and emittance in MBE-4, an experimental multiple beam induction linear accelerator for heavy ions

    International Nuclear Information System (INIS)

    Warwick, A.I.; Gough, D.E.; Keefe, D.; Meuth, H.

    1989-01-01

    The authors report on the implementation of a second schedule of acceleration and current amplification in MBE-4. Control of the beam current within the bunch is improved over that in the first schedule by the addition of several small amplitude induction pulsers to compensate for acceleration errors and to control the ends of the bunch. Measurements of the longitudinal and transverse emittance are presented. 5 refs., 3 figs., 1 tab

  20. Chromosome X-wide association study identifies Loci for fasting insulin and height and evidence for incomplete dosage compensation.

    Directory of Open Access Journals (Sweden)

    Taru Tukiainen

    2014-02-01

    Full Text Available The X chromosome (chrX represents one potential source for the "missing heritability" for complex phenotypes, which thus far has remained underanalyzed in genome-wide association studies (GWAS. Here we demonstrate the benefits of including chrX in GWAS by assessing the contribution of 404,862 chrX SNPs to levels of twelve commonly studied cardiometabolic and anthropometric traits in 19,697 Finnish and Swedish individuals with replication data on 5,032 additional Finns. By using a linear mixed model, we estimate that on average 2.6% of the additive genetic variance in these twelve traits is attributable to chrX, this being in proportion to the number of SNPs in the chromosome. In a chrX-wide association analysis, we identify three novel loci: two for height (rs182838724 near FGF16/ATRX/MAGT1, joint P-value = 2.71×10(-9, and rs1751138 near ITM2A, P-value = 3.03×10(-10 and one for fasting insulin (rs139163435 in Xq23, P-value = 5.18×10(-9. Further, we find that effect sizes for variants near ITM2A, a gene implicated in cartilage development, show evidence for a lack of dosage compensation. This observation is further supported by a sex-difference in ITM2A expression in whole blood (P-value = 0.00251, and is also in agreement with a previous report showing ITM2A escapes from X chromosome inactivation (XCI in the majority of women. Hence, our results show one of the first links between phenotypic variation in a population sample and an XCI-escaping locus and pinpoint ITM2A as a potential contributor to the sexual dimorphism in height. In conclusion, our study provides a clear motivation for including chrX in large-scale genetic studies of complex diseases and traits.

  1. Minimization of the emittance growth of multi-charge particle beams in the charge stripping section of RAON

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji-Gwang [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Kim, Eun-San, E-mail: eskim1@knu.ac.kr [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Kim, Hye-Jin, E-mail: hjkim87@ibs.re.kr [Rare Isotope Science Project, Institute for Basic Science, Jeonmin-dong, Yuseong-gu, Daejeon (Korea, Republic of); Jeon, Dong-O [Rare Isotope Science Project, Institute for Basic Science, Jeonmin-dong, Yuseong-gu, Daejeon (Korea, Republic of)

    2014-12-11

    The charge stripping section of the Rare isotope Accelerator Of Newness (RAON), which is one of the critical components to achieve a high power of 400 kW with a short lianc, is a source of transverse emittance growth. The dominant effects are the angular straggling in the charge stripper required to increase the charge state of the beam and chromatic aberrations in the dispersive section required to separate the selected ion beam from the various ion beams produced in the stripper. Since the main source of transverse emittance growth in the stripper is the angular straggling, it can be compensated for by changing the angle of the phase ellipse. Therefore the emittance growth is minimized by optimizing the Twiss parameters at the stripper. The emittance growth in the charge selection section is also minimized by the correction of high-order aberrations using six sextupole magnets. In this paper, we present a method to minimize the transverse emittance growth in the stripper by changing the Twiss parameters and in the charge selection section by using sextupole magnets.

  2. Test results on two thermionic converters with cermet emitters

    International Nuclear Information System (INIS)

    Saunders, M.; Danielson, L.; Huffman, F.

    1983-01-01

    An emitter made of a directionally solidified Mo-Al 2 O 3 , Cr 2 O 3 eutectic was provided by Eindhoven University of Technology in Eindhoven, The Netherlands. Although the high temperature braze cycle used in bonding this electrode to the emitter substrate destroyed its characteristic needle microstructure, the converter gave good performance. Apparently, chemical species evaporated from the emitter onto the collector provided a low collector work function. The resulting low barrier indices suggest that this surface is a promising emitter

  3. Does Miscanthus cultivation on organic soils compensate for carbon loss from peat oxidation? A dual label study

    Science.gov (United States)

    Bader, Cédric; Leifeld, Jens; Müller, Moritz; Schulin, Rainer

    2016-04-01

    Agricultural use of organic soils requires drainage and thereby changes conditions in these soils from anoxic to oxic. As a consequence, organic carbon that had been accumulated over millennia is rapidly mineralized, so that these soils are converted from a CO2 sink to a source. The peat mineralization rate depends mainly on drainage depth, but also on crop type. Various studies show that Miscanthus, a C4 bioenergy plant, shows potential for carbon sequestration in mineral soils because of its high productivity, its dense root system, absence of tillage and high preharvest litterfall. If Miscanthus cropping would have a similar effect in organic soils, peat consumption and thus CO2 emissions might be reduced. For our study we compared two adjacent fields, on which organic soil is cultivated with Miscanthus (since 20 years) and perennial grass (since 6 years). Both sites are located in the Bernese Seeland, the largest former peatland area of Switzerland. To determine wether Miscanthus-derived carbon accumulated in the organic soil, we compared the stable carbon isotopic signatures of the experimental soil with those of an organic soil without any C4-plant cultivation history. To analyze the effect of C4-C accumulation on peat degradability we compared the CO2 emissions by incubating 90 soil samples of the two fields for more than one year. Additionally, we analysed the isotopic CO2 composition (13C, 14C) during the first 25 days of incubation after trapping the emitted CO2 in NaOH and precipitating it as BaCO3. The ∂13C values of the soil imply, that the highest share of C4-C of around 30% is situated at a depth of 10-20 cm. Corn that used to be cultivated on the grassland field before 2009 still accounts for 8% of SOC. O/C and H/C ratios of the peat samples indicate a stronger microbial imprint of organic matter under Miscanthus cultivation. The amount of CO2 emitted was not affected by the cultivation type. On average 57% of the CO2 was C4 derived in the

  4. Cooperation, compensation and transition

    NARCIS (Netherlands)

    Ju, Y.

    2004-01-01

    Cooperation and compensation are two important and well-linked issues in economics. The central question in cooperation is how to share the joint gains among participating players. Compensation is a specific aspect of surplus sharing problems providing incentives for agents to sacrifice their own

  5. Options in Compensation

    DEFF Research Database (Denmark)

    Flor, Christian Riis; Frimor, Hans; Munk, Claus

    2014-01-01

    We derive the optimal compensation contract in a principal–agent setting in which outcome is used to provide incentives for both effort and risky investments. To motivate investment, optimal compensation entails rewards for high as well as low outcomes, and it is increasing at the mean outcome...

  6. Economic and financial benefits as a compensation for living near a nuclear power station. A case study of Kashiwazaki-Kariwa Nuclear Power Station

    International Nuclear Information System (INIS)

    Kato, Takaaki; Hatta, Masahisa; Matsumoto, Shiro; Nishikawa, Masashi

    2007-01-01

    Although dwellers living near a nuclear power station are entitled to economic/financial benefits such as increased job opportunities and local tax revenues pertaining to the power station, it is not clear whether such benefits are appreciated by the dwellers. Two findings of this study based upon a social survey of local dwellers living near the Kashiwazaki-Kariwa Nuclear Power Station are summarized as follows. First, an increase in the per capita sizes of the local tax revenue and national subsidies resulted in a larger share of respondents who thought that those revenues are beneficial. Therefore, local dwellers are aware of the sizes of economic/financial benefits. Second, given the same risk level of nuclear disaster, a larger per capita financial benefit resulted in a larger share of respondents who felt compensated for the nuclear risk. However, this increase in the number of compensated respondents is low relative to the increase in the amount of financial benefits. (author)

  7. Successful Beam-Beam Tuneshift Compensation

    Energy Technology Data Exchange (ETDEWEB)

    Bishofberger, Kip Aaron [Univ. of California, Los Angeles, CA (United States)

    2005-01-01

    The performance of synchrotron colliders has been limited by the beam-beam limit, a maximum tuneshift that colliding bunches could sustain. Due to bunch-to-bunch tune variation and intra-bunch tune spread, larger tuneshifts produce severe emittance growth. Breaking through this constraint has been viewed as impossible for several decades. This dissertation introduces the physics of ultra-relativistic synchrotrons and low-energy electron beams, with emphasis placed on the limits of the Tevatron and the needs of a tuneshift-compensation device. A detailed analysis of the Tevatron Electron Lens (TEL) is given, comparing theoretical models to experimental data whenever possible. Finally, results of Tevatron operations with inclusion of the TEL are presented and analyzed. It is shown that the TEL provides a way to shatter the previously inescapable beam-beam limit.

  8. The Prototype Inductive Adder With Droop Compensation for the CLIC Kicker Systems

    CERN Document Server

    Holma, J

    2014-01-01

    The Compact Linear Collider (CLIC) study is exploring the scheme for an electron-positron collider with high luminosity and a nominal center-of-mass energy of 3 TeV. The CLIC predamping rings and damping rings (DRs) will produce, through synchrotron radiation, an ultralow emittance beam with high bunch charge. To avoid beam emittance increase, the DR kicker systems must provide extremely flat, high-voltage, pulses. The specifications for the extraction kickers of the DRs are particularly demanding: the flattops of the pulses must be ±12.5 kV with a combined ripple and droop of not more than ±0.02% (±2.5 V). An inductive adder is a very promising approach to meeting the specifications. Recently, a five-layer prototype has been built at CERN. Passive analog modulation has been applied to compensate the voltage droop, for example of the pulse capacitors. The output waveforms of the prototype inductive adder have been compared with predictions of the voltage droop and pulse shape. Conclusions are drawn concern...

  9. 2-D emittance equation with acceleration and compression

    International Nuclear Information System (INIS)

    Hahn, K.D.; Smith, L.

    1988-10-01

    Since both acceleration and compression are required for an Inertial Fusion Driver, the understanding of their effect on the beam quality, emittance, is important. This report attempts to generalize the usual emittance formula for the drifting beam to include these effects. The derivation of the 2-D emittance equation is carried out and a comparison with the particle code results is given. The 2-D emittance at a given axial location is reasonable to consider for a long beam, particularly with velocity tilt; transverse emittance averaged over the entire bunch is not a useful quantity. 6 refs., 2 figs., 1 tab

  10. Small horizontal emittance in the TESLA damping ring

    International Nuclear Information System (INIS)

    Decking, W.

    2001-01-01

    The present TESLA damping ring is designed for a normalized horizontal emittance of 8x10 -6 m. γ-γ collisions at the TESLA linear collider will benefit from a further decrease of the horizontal emittance. This paper reviews the processes which limit the horizontal emittance in the damping ring. Preliminary estimates on the smallest horizontal emittance for the present TESLA damping ring design as well as an ultimate limit of the emittance reachable with the TESLA damping ring concept will be given

  11. Differences in baseline factors and survival between normocapnia, compensated respiratory acidosis and decompensated respiratory acidosis in COPD exacerbation: A pilot study.

    Science.gov (United States)

    Lun, Chung-Tat; Tsui, Miranda S N; Cheng, Suet-Lai; Chan, Veronica L; Leung, Wah-Shing; Cheung, Alice P S; Chu, Chung-Ming

    2016-01-01

    Patients with chronic obstructive pulmonary disease (COPD) experiencing acute exacerbation (AE-COPD) with decompensated respiratory acidosis are known to have poor outcomes in terms of recurrent respiratory failure and death. However, the outcomes of AE-COPD patients with compensated respiratory acidosis are not known. We performed a 1-year prospective, single-centre, cohort study in patients surviving the index admission for AE-COPD to compare baseline factors between groups with normocapnia, compensated respiratory acidosis and decompensated respiratory acidosis. Survival analysis was done to examine time to readmissions, life-threatening events and death. A total of 250 patients fulfilling the inclusion and exclusion criteria were recruited and 245 patients were analysed. Compared with normocapnia, both compensated and decompensated respiratory acidosis are associated with lower FEV1 % (P respiratory acidosis, there was no difference in FEV1 (% predicted) (P = 0.15), GOLD stage (P = 0.091), BODE index (P = 0.158) or time to life-threatening events (P = 0.301). High PaCO2 level (P = 0.002) and previous use of non-invasive ventilation (NIV) in acute setting (P respiratory acidosis are associated with poorer lung function and higher risk of future life-threatening events. High PaCO2 level and past history of NIV use in acute settings were predictive factors for future life-threatening events. Compensated respiratory acidosis warrants special attention and optimization of medical therapy as it poses risk of life-threatening events. © 2015 Asian Pacific Society of Respirology.

  12. [Study on the Effects and Compensation Effect of Recording Parameters Error on Imaging Performance of Holographic Grating in On-Line Spectral Diagnose].

    Science.gov (United States)

    Jiang, Yan-xiu; Bayanheshig; Yang, Shuo; Zhao, Xu-long; Wu, Na; Li, Wen-hao

    2016-03-01

    To making the high resolution grating, a numerical calculation was used to analyze the effect of recording parameters on groove density, focal curve and imaging performance of the grating and their compensation. Based on Fermat' s principle, light path function and aberration, the effect on imaging performance of the grating was analyzed. In the case of fixed using parameters, the error of the recording angle has a greater influence on imaging performance, therefore the gain of the weight of recording angle can improve the accuracy of the recording angle values in the optimization; recording distance has little influence on imaging performance; the relative errors of recording parameters cause the change of imaging performance of the grating; the results indicate that recording parameter errors can be compensated by adjusting its corresponding parameter. The study can give theoretical guidance to the fabrication for high resolution varied-line-space plane holographic grating in on-line spectral diagnostic and reduce the alignment difficulty by analyze the main error effect the imaging performance and propose the compensation method.

  13. Development of Emittance Analysis Software for Ion Beam Characterization

    International Nuclear Information System (INIS)

    Padilla, M.J.; Liu, Yuan

    2007-01-01

    Transverse beam emittance is a crucial property of charged particle beams that describes their angular and spatial spread. It is a figure of merit frequently used to determine the quality of ion beams, the compatibility of an ion beam with a given beam transport system, and the ability to suppress neighboring isotopes at on-line mass separator facilities. Generally, a high-quality beam is characterized by a small emittance. In order to determine and improve the quality of ion beams used at the Holifield Radioactive Ion Beam Facility (HRIBF) for nuclear physics and nuclear astrophysics research, the emittances of the ion beams are measured at the off-line Ion Source Test Facilities. In this project, emittance analysis software was developed to perform various data processing tasks for noise reduction, to evaluate root-mean-square emittance, Twiss parameters, and area emittance of different beam fractions. The software also provides 2D and 3D graphical views of the emittance data, beam profiles, emittance contours, and RMS. Noise exclusion is essential for accurate determination of beam emittance values. A Self-Consistent, Unbiased Elliptical Exclusion (SCUBEEx) method is employed. Numerical data analysis techniques such as interpolation and nonlinear fitting are also incorporated into the software. The software will provide a simplified, fast tool for comprehensive emittance analysis. The main functions of the software package have been completed. In preliminary tests with experimental emittance data, the analysis results using the software were shown to be accurate

  14. DEVELOPMENT OF EMITTANCE ANALYSIS SOFTWARE FOR ION BEAM CHARACTERIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Padilla, M. J.; Liu, Y.

    2007-01-01

    Transverse beam emittance is a crucial property of charged particle beams that describes their angular and spatial spread. It is a fi gure of merit frequently used to determine the quality of ion beams, the compatibility of an ion beam with a given beam transport system, and the ability to suppress neighboring isotopes at on-line mass separator facilities. Generally a high quality beam is characterized by a small emittance. In order to determine and improve the quality of ion beams used at the Holifi eld Radioactive Ion beam Facility (HRIBF) for nuclear physics and nuclear astrophysics research, the emittances of the ion beams are measured at the off-line Ion Source Test Facilities. In this project, emittance analysis software was developed to perform various data processing tasks for noise reduction, to evaluate root-mean-square emittance, Twiss parameters, and area emittance of different beam fractions. The software also provides 2D and 3D graphical views of the emittance data, beam profi les, emittance contours, and RMS. Noise exclusion is essential for accurate determination of beam emittance values. A Self-Consistent, Unbiased Elliptical Exclusion (SCUBEEx) method is employed. Numerical data analysis techniques such as interpolation and nonlinear fi tting are also incorporated into the software. The software will provide a simplifi ed, fast tool for comprehensive emittance analysis. The main functions of the software package have been completed. In preliminary tests with experimental emittance data, the analysis results using the software were shown to be accurate.

  15. Multiple Compensation Consultants and CEO Pay

    NARCIS (Netherlands)

    Kabir, Mohammed Rezaul; Minhat, Marizah

    The study examines the practice of employing multiple compensation consultants. Data for a sample of UK companies over the period 2003-2006 are analyzed using a variety of econometric methods. We find that CEOs receive higher equity-based pay when firms employ more than one compensation consultant.

  16. Ghost signals in Allison emittance scanners

    International Nuclear Information System (INIS)

    Stockli, Martin P.; Leitner, M.; Moehs, D.P.; Keller, R.; Welton, R.F.

    2004-01-01

    For over 20 years, Allison scanners have been used to measure emittances of low-energy ion beams. We show that scanning large trajectory angles produces ghost signals caused by the sampled beamlet impacting on an electric deflection plate. The ghost signal strength is proportional to the amount of beam entering the scanner. Depending on the ions, and their velocity, the ghost signals can have the opposite or the same polarity as the main beam signals. The ghost signals cause significant errors in the emittance estimates because they appear at large trajectory angles. These ghost signals often go undetected because they partly overlap with the real signals, are mostly below the 1% level, and often hide in the noise. A simple deflection plate modification is shown to reduce the ghost signal strength by over 99%

  17. Computing Eigen-Emittances from Tracking Data

    Energy Technology Data Exchange (ETDEWEB)

    Alexahin, Y. [Fermilab

    2014-09-18

    In a strongly nonlinear system the particle distribution in the phase space may develop long tails which contribution to the covariance (sigma) matrix should be suppressed for a correct estimate of the beam emittance. A method is offered based on Gaussian approximation of the original particle distribution in the phase space (Klimontovich distribution) which leads to an equation for the sigma matrix which provides efficient suppression of the tails and cannot be obtained by introducing weights. This equation is easily solved by iterations in the multi-dimensional case. It is also shown how the eigen-emittances and coupled optics functions can be retrieved from the sigma matrix in a strongly coupled system. Finally, the developed algorithm is applied to 6D ionization cooling of muons in HFOFO channel.

  18. Reducing longitudinal emittance growth in RFQ accelerators

    International Nuclear Information System (INIS)

    Koscielniak, S.

    1994-08-01

    Bunching and capture of a monochromatic beam into an rf bucket inevitably lead to substantial emittance growth through the mechanisms of filamentation and non-adiabatic variation of parameters. We describe a three step strategy for minimizing this growth, based on a clear understanding of the non-linear beam dynamics, and apply to acceleration of heavy ions with Z/A = 1/60 (and initial kinetic energy 60 keV/u) in a radio frequency quadrupole (RFQ) operating at 25 MHz. We also describe a scheme, to further reduce the emittance, based upon the use of an external RFQ-type prebuncher before the main accelerator. The external unit permits the bunching voltage to be reduced, to inject into a moving bucket, and to reduce the structure length. (author). 7 refs., 6 figs

  19. Ghost Signals In Allison Emittance Scanners

    International Nuclear Information System (INIS)

    Stockli, Martin P.; Leitner, M.; Keller, R.; Moehs, D.P.; Welton, R. F.

    2005-01-01

    For over 20 years, Allison scanners have been used to measure emittances of low-energy ion beams. We show that scanning large trajectory angles produces ghost signals caused by the sampled beamlet impacting on an electric deflection plate. The ghost signal strength is proportional to the amount of beam entering the scanner. Depending on the ions, and their velocity, the ghost signals can have the opposite or the same polarity as the main beam signals. The ghost signals cause significant errors in the emittance estimates because they appear at large trajectory angles. These ghost signals often go undetected because they partly overlap with the real signals, are mostly below the 1% level, and often hide in the noise. A simple deflection plate modification is shown to reduce the ghost signal strength by over 99%

  20. Photonic Crystal Emitters for Thermophotovoltaic Energy Conversion

    International Nuclear Information System (INIS)

    Stelmakh, Veronika; Chan, Walker R; Joannopoulos, John D; Celanovic, Ivan; Ghebrebrhan, Michael; Soljacic, Marin

    2015-01-01

    This paper reports the design, fabrication, and characterization of 2D photonic crystal (PhC) thermal emitters for a millimeter-scale hydrocarbon TPV microgenerator as a possible replacement for batteries in portable microelectronics, robotics, etc. In our TPV system, combustion heats a PhC emitter to incandescence and the resulting radiation is converted by a low-bandgap TPV cell. The PhC tailors the photonic density of states to produce spectrally confined thermal emission that matches the bandgap of the TPV cell, enabling high heat-to-electricity conversion efficiency. The work builds on a previously developed fabrication process to produce a square array of cylindrical cavities in a metal substrate. We will present ongoing incremental improvements in the optical and thermo-mechanical properties, the fabrication process, and the system integration, as recently combined with fabrication using novel materials, such as sputtered coatings, to enable a monolithic system. (paper)

  1. Reactive power compensator

    Science.gov (United States)

    El-Sharkawi, Mohamed A.; Venkata, Subrahmanyam S.; Chen, Mingliang; Andexler, George; Huang, Tony

    1992-01-01

    A system and method for determining and providing reactive power compensation for an inductive load. A reactive power compensator (50,50') monitors the voltage and current flowing through each of three distribution lines (52a, 52b, 52c), which are supplying three-phase power to one or more inductive loads. Using signals indicative of the current on each of these lines when the voltage waveform on the line crosses zero, the reactive power compensator determines a reactive power compensator capacitance that must be connected to the lines to maintain a desired VAR level, power factor, or line voltage. Alternatively, an operator can manually select a specific capacitance for connection to each line, or the capacitance can be selected based on a time schedule. The reactive power compensator produces control signals, which are coupled through optical fibers (102/106) to a switch driver (110, 110') to select specific compensation capacitors (112) for connections to each line. The switch driver develops triggering signals that are supplied to a plurality of series-connected solid state switches (350), which control charge current in one direction in respect to ground for each compensation capacitor. During each cycle, current flows from ground to charge the capacitors as the voltage on the line begins to go negative from its positive peak value. The triggering signals are applied to gate the solid state switches into a conducting state when the potential on the lines and on the capacitors reaches a negative peak value, thereby minimizing both the potential difference and across the charge current through the switches when they begin to conduct. Any harmonic distortion on the potential and current carried by the lines is filtered out from the current and potential signals used by the reactive power compensator so that it does not affect the determination of the required reactive compensation.

  2. Reactive power compensator

    Energy Technology Data Exchange (ETDEWEB)

    El-Sharkawi, Mohamed A. (Renton, WA); Venkata, Subrahmanyam S. (Woodinville, WA); Chen, Mingliang (Kirkland, WA); Andexler, George (Everett, WA); Huang, Tony (Seattle, WA)

    1992-01-01

    A system and method for determining and providing reactive power compensation for an inductive load. A reactive power compensator (50,50') monitors the voltage and current flowing through each of three distribution lines (52a, 52b, 52c), which are supplying three-phase power to one or more inductive loads. Using signals indicative of the current on each of these lines when the voltage waveform on the line crosses zero, the reactive power compensator determines a reactive power compensator capacitance that must be connected to the lines to maintain a desired VAR level, power factor, or line voltage. Alternatively, an operator can manually select a specific capacitance for connection to each line, or the capacitance can be selected based on a time schedule. The reactive power compensator produces control signals, which are coupled through optical fibers (102/106) to a switch driver (110, 110') to select specific compensation capacitors (112) for connections to each line. The switch driver develops triggering signals that are supplied to a plurality of series-connected solid state switches (350), which control charge current in one direction in respect to ground for each compensation capacitor. During each cycle, current flows from ground to charge the capacitors as the voltage on the line begins to go negative from its positive peak value. The triggering signals are applied to gate the solid state switches into a conducting state when the potential on the lines and on the capacitors reaches a negative peak value, thereby minimizing both the potential difference and across the charge current through the switches when they begin to conduct. Any harmonic distortion on the potential and current carried by the lines is filtered out from the current and potential signals used by the reactive power compensator so that it does not affect the determination of the required reactive compensation.

  3. Studies on the kinetics of unconjugated [14C]bilirubin metabolism in normal subjects and patients with compensated cirrhosis

    International Nuclear Information System (INIS)

    Owens, D.; Jones, E.A.; Carson, E.R.

    1977-01-01

    The kinetics of unconjugated 14 C-bilirubin metabolism have been investigated and analysed in terms of a three-pool model in a group of seven normal subjects and in a group of eight cirrhotic patients who had appreciable impairment of liver cell function. The results indicate that, in patients with compensated cirrhosis, the efficiency of the liver in extracting unconjugated bilirubin from plasma against a concentration gradient is impaired, even though the liver's capacity to conjugate bilirubin may be normal. As a consequence of the increased volume of distribution, the absolute hepatic clearance of unconjugated bilirubin is relatively well maintained. (author)

  4. Study of instabilities and emittance growth in periodic focusing systems for intense beams. Technical report No. PP 82-142. Progress report

    International Nuclear Information System (INIS)

    Reiser, M.

    1982-03-01

    Experimental studies of beam properties and nonlinear effects with one and two solenoid lenses have yielded a large amount of valuable data. Several phenomena were identified and explored such as images and halos and formation of pronounced hollow beam profiles after passage through the lenses. The hollow beam effect is qualitatively attributed to nonlinear space charge forces and lens aberrations. The main research effort during the past year was devoted to the experimental investigation of beam focusing with one and two solenoid lenses

  5. Complementary methods of transverse emittance measurement

    Energy Technology Data Exchange (ETDEWEB)

    Zagel, James; Hu, Martin; Jansson, Andreas; Thurman-Keup, Randy; Yan, Ming-Jen; /Fermilab

    2008-05-01

    Several complementary transverse emittance monitors have been developed and used at the Fermilab accelerator complex. These include Ionization profile Monitors (IPM), Flying Wires, Schottky detectors and a Synchrotron Light Monitor (Synchlite). Mechanical scrapers have also been used for calibration purposes. This paper describes the various measurement devices by examining their basic features, calibration requirements, systematic uncertainties, and applications to collider operation. A comparison of results from different kinds of measurements is also presented.

  6. Modular low-voltage electron emitters

    International Nuclear Information System (INIS)

    Berejka, Anthony J.

    2005-01-01

    Modular, low-voltage electron emitters simplify electron beam (EB) technology for many industrial uses and for research and development. Modular electron emitters are produced in quantity as sealed systems that are evacuated at the factory, eliminating the need for vacuum pumps at the point of use. A plug-out-plug-in method of replacement facilitates servicing. By using an ultra-thin 6-7 μm titanium foil window, solid-state power supplies, an innovative design to extract and spread the beam (enabling systems to be placed adjacent to each other to extend beam width) and touch-screen computer controls, these modular units combine ease of use and electrical transfer efficiency at voltages that can be varied between 80 kV and 150 kV with beam currents up to 40 mA per 25 cm across the beam window. These new devices have been made in three widths: 5 cm, 25 cm, and 40 cm. Details of the beam construction and illustrations of industrial uses will be presented. Traditional uses in the graphic arts and coatings areas have welcomed this modular technology as well as uses for surface sterilization. Being compact and lightweight (∼15 kg/emitter), these modular beams have been configured around complex shapes to achieve three-dimensional surface curing at high production rates

  7. Modular low-voltage electron emitters

    Science.gov (United States)

    Berejka, Anthony J.

    2005-12-01

    Modular, low-voltage electron emitters simplify electron beam (EB) technology for many industrial uses and for research and development. Modular electron emitters are produced in quantity as sealed systems that are evacuated at the factory, eliminating the need for vacuum pumps at the point of use. A plug-out-plug-in method of replacement facilitates servicing. By using an ultra-thin 6-7 μm titanium foil window, solid-state power supplies, an innovative design to extract and spread the beam (enabling systems to be placed adjacent to each other to extend beam width) and touch-screen computer controls, these modular units combine ease of use and electrical transfer efficiency at voltages that can be varied between 80 kV and 150 kV with beam currents up to 40 mA per 25 cm across the beam window. These new devices have been made in three widths: 5 cm, 25 cm, and 40 cm. Details of the beam construction and illustrations of industrial uses will be presented. Traditional uses in the graphic arts and coatings areas have welcomed this modular technology as well as uses for surface sterilization. Being compact and lightweight (∼15 kg/emitter), these modular beams have been configured around complex shapes to achieve three-dimensional surface curing at high production rates.

  8. Field emission from optimized structure of carbon nanotube field emitter array

    International Nuclear Information System (INIS)

    Chouhan, V.; Noguchi, T.; Kato, S.

    2016-01-01

    The authors report a detail study on the emission properties of field emitter array (FEA) of micro-circular emitters of multiwall carbon nanotubes (CNTs). The FEAs were fabricated on patterned substrates prepared with an array of circular titanium (Ti) islands on titanium nitride coated tantalum substrates. CNTs were rooted into these Ti islands to prepare an array of circular emitters. The circular emitters were prepared in different diameters and pitches in order to optimize their structure for acquiring a high emission current. The pitch was varied from 0 to 600 μm, while a diameter of circular emitters was kept constant to be 50 μm in order to optimize a pitch. For diameter optimization, a diameter was changed from 50 to 200 μm while keeping a constant edge-to-edge distance of 150 μm between the circular emitters. The FEA with a diameter of 50 μm and a pitch of 120 μm was found to be the best to achieve an emission current of 47 mA corresponding to an effective current density of 30.5 A/cm"2 at 7 V/μm. The excellent emission current was attributed to good quality of CNT rooting into the substrate and optimized FEA structure, which provided a high electric field on a whole circular emitter of 50 μm and the best combination of the strong edge effect and CNT coverage. The experimental results were confirmed with computer simulation.

  9. Surface-conduction electron-emitter characteristics and fabrication based on vertically aligned carbon nanotube arrays

    Energy Technology Data Exchange (ETDEWEB)

    Shih, Yi-Ting [Graduate Institute of Electro-Optical Engineering, National Taiwan University of Science and Technology, No. 43, Section 4, Keelung Road, Taipei 10607, Taiwan (China); Li, Kuan-Wei [Department of Electronic and Computer Engineering, National Taiwan University of Science and Technology, No. 43, Section 4, Keelung Road, Taipei 10607, Taiwan (China); Honda, Shin-ichi [Graduate School of Engineering, University of Hyogo, 2167 Shosha, Himeji, Hyogo 671-2280 (Japan); Lin, Pao-Hung; Huang, Ying-Sheng [Graduate Institute of Electro-Optical Engineering, National Taiwan University of Science and Technology, No. 43, Section 4, Keelung Road, Taipei 10607, Taiwan (China); Department of Electronic and Computer Engineering, National Taiwan University of Science and Technology, No. 43, Section 4, Keelung Road, Taipei 10607, Taiwan (China); Lee, Kuei-Yi, E-mail: kylee@mail.ntust.edu.tw [Graduate Institute of Electro-Optical Engineering, National Taiwan University of Science and Technology, No. 43, Section 4, Keelung Road, Taipei 10607, Taiwan (China); Department of Electronic and Computer Engineering, National Taiwan University of Science and Technology, No. 43, Section 4, Keelung Road, Taipei 10607, Taiwan (China)

    2017-06-01

    Graphical abstract: The pattern design provides a new structure of surface-conduction electron-emitter display (SED). Delta-star shaped vertically aligned CNT (VACNT) arrays with 20o tips can simultaneously provide three emitters to bombard the sides of equilateral triangles pattern of VACNT, which produces numerous secondary electrons and enhance the SED efficiency. - Highlights: • The carbon nanotube (CNT) has replaced palladium oxide (PdO) as the electrode material for surface-conduction electron-emitter (SCE) applications. • The vertically aligned CNT (VACNT) arrays with 20° tips of the delta-star arrangement are used as cathodes that easily emit electrons. The cathode pattern simultaneously provides three emitters to bombard the sides of equilateral triangles pattern of VACNT. • The VACNT arrays were covered with magnesium oxide (MgO) nanostructures to promote the surface-conduction electron-emitter display (SED) efficiency (η). • The η was stably maintained in the 75–85% range. The proposed design provides a facile new method for developing SED applications. - Abstract: The carbon nanotube (CNT) has replaced palladium oxide (PdO) as the electrode material for surface-conduction electron-emitter (SCE) applications. Vertically aligned CNT arrays with a delta-star arrangement were patterned and synthesized onto a quartz substrate using photolithography and thermal chemical vapor deposition. Delta-star shaped VACNT arrays with 20° tips are used as cathodes that easily emit electrons because of their high electrical field gradient. In order to improve the field emission and secondary electrons (SEs) in SCE applications, magnesium oxide (MgO) nanostructures were coated onto the VACNT arrays to promote the surface-conduction electron-emitter display (SED) efficiency (η). According to the definition of η in SCE applications, in this study, the η was stably maintained in the 75–85% range. The proposed design provides a facile new method for

  10. Field emission from optimized structure of carbon nanotube field emitter array

    Energy Technology Data Exchange (ETDEWEB)

    Chouhan, V., E-mail: vchouhan@post.kek.jp, E-mail: vijaychouhan84@gmail.com [School of High Energy Accelerator, The Graduate University for Advanced Studies, Tsukuba 305-0801 (Japan); Noguchi, T. [High Energy Accelerator Research Organization (KEK), Tsukuba 305-0801 (Japan); Kato, S. [School of High Energy Accelerator, The Graduate University for Advanced Studies, Tsukuba 305-0801 (Japan); High Energy Accelerator Research Organization (KEK), Tsukuba 305-0801 (Japan)

    2016-04-07

    The authors report a detail study on the emission properties of field emitter array (FEA) of micro-circular emitters of multiwall carbon nanotubes (CNTs). The FEAs were fabricated on patterned substrates prepared with an array of circular titanium (Ti) islands on titanium nitride coated tantalum substrates. CNTs were rooted into these Ti islands to prepare an array of circular emitters. The circular emitters were prepared in different diameters and pitches in order to optimize their structure for acquiring a high emission current. The pitch was varied from 0 to 600 μm, while a diameter of circular emitters was kept constant to be 50 μm in order to optimize a pitch. For diameter optimization, a diameter was changed from 50 to 200 μm while keeping a constant edge-to-edge distance of 150 μm between the circular emitters. The FEA with a diameter of 50 μm and a pitch of 120 μm was found to be the best to achieve an emission current of 47 mA corresponding to an effective current density of 30.5 A/cm{sup 2} at 7 V/μm. The excellent emission current was attributed to good quality of CNT rooting into the substrate and optimized FEA structure, which provided a high electric field on a whole circular emitter of 50 μm and the best combination of the strong edge effect and CNT coverage. The experimental results were confirmed with computer simulation.

  11. The Brookhaven ATF low-emittance beam line

    International Nuclear Information System (INIS)

    Wang, X.J.; Kirk, H.G.

    1991-01-01

    One component of the experimental program at the Brookhaven Accelerator Test Facility (ATF) consists of a class of experiments which will study the acceleration of electrons through micron-size structures which are exposed in coincidence to a 100 GW CO 2 laser beam. These experiments require the development and control of an electron beam with geometric emittances on the order of 10 -10 m-rad and intensities on the order of 10 6 electrons. In this paper, the authors describe the strategies for producing such beams and the effects of higher-order aberrations. Particle tracking results are presented for the final-focus system

  12. The Brookhaven ATF low-emittance beam line

    International Nuclear Information System (INIS)

    Wang, X.J.

    1991-01-01

    One component of the experimental program at the Brookhaven Accelerator Test Facility (ATF) consists of a class of experiments which will study the acceleration of electrons through micron-size structures which are exposed in coincidence to a 100 GW CO 2 laser beam. These experiments require the development and control of an electron beam with geometric emittances on the order of 10 -10 m-rad and intensities on the order of 10 6 electrons. In this paper, we describe the strategies for producing such beams and the effects of high-order aberrations. Particle tracking results are presented for the final-focus system. 9 refs., 6 figs., 2 tabs

  13. Measurement of Alpha Emitters Concentration in Imported Cigarettes

    International Nuclear Information System (INIS)

    Nasser Allah, Z.K.; Musa, W.A.; AL-Rawi, A.A.S.

    2011-01-01

    The aime of this study was to measured the alpha emitters concentration of (15) different kinds of imported cigarettes. the nuclear reaction used U-235(n, f) obtained by the bombardment of U-235 with thermal neutrons from (Am B e)neutron source with thermal flux of(5*10 3 n.cm -2 .s -1 ). The Results obtained showed the values of the Uranium concentration, and varies from (0.041 ppm) in five stares kind to (2.374ppm) in Machbeth (chocolate) 100's kind. All the result obtained are within the limit levels as given by UNSCAR data

  14. Climate change and compensation

    DEFF Research Database (Denmark)

    Jensen, Karsten Klint; Flanagan, Tine Bech

    2013-01-01

    This paper presents a case for compensation of actual harm from climate change in the poorest countries. First, it is shown that climate change threatens to reverse the fight to eradicate poverty. Secondly, it is shown how the problems raised in the literature for compensation to some extent...... are based on misconceptions and do not apply to compensation of present actual harm. Finally, two arguments are presented to the effect that, in so far as developed countries accept a major commitment to mitigate climate change, they should also accept a commitment to address or compensate actual harm from...... climate change. The first argument appeals to the principle that if it is an injustice to cause risk of incurring harm in the future, then it is also an injustice to cause a similar harm now. The second argument appeals to the principle that if there is moral reason to reduce the risk of specific harms...

  15. Workers Compensation Claim Data -

    Data.gov (United States)

    Department of Transportation — This data set contains DOT employee workers compensation claim data for current and past DOT employees. Types of data include claim data consisting of PII data (SSN,...

  16. Synchrony - Cyberknife Respiratory Compensation Technology

    International Nuclear Information System (INIS)

    Ozhasoglu, Cihat; Saw, Cheng B.; Chen Hungcheng; Burton, Steven; Komanduri, Krishna; Yue, Ning J.; Huq, Saiful M.; Heron, Dwight E.

    2008-01-01

    Studies of organs in the thorax and abdomen have shown that these organs can move as much as 40 mm due to respiratory motion. Without compensation for this motion during the course of external beam radiation therapy, the dose coverage to target may be compromised. On the other hand, if compensation of this motion is by expansion of the margin around the target, a significant volume of normal tissue may be unnecessarily irradiated. In hypofractionated regimens, the issue of respiratory compensation becomes an important factor and is critical in single-fraction extracranial radiosurgery applications. CyberKnife is an image-guided radiosurgery system that consists of a 6-MV LINAC mounted to a robotic arm coupled through a control loop to a digital diagnostic x-ray imaging system. The robotic arm can point the beam anywhere in space with 6 degrees of freedom, without being constrained to a conventional isocenter. The CyberKnife has been recently upgraded with a real-time respiratory tracking and compensation system called Synchrony. Using external markers in conjunction with diagnostic x-ray images, Synchrony helps guide the robotic arm to move the radiation beam in real time such that the beam always remains aligned with the target. With the aid of Synchrony, the tumor motion can be tracked in three-dimensional space, and the motion-induced dosimetric change to target can be minimized with a limited margin. The working principles, advantages, limitations, and our clinical experience with this new technology will be discussed

  17. Probing the emitter site of Renilla luciferase using small organic molecules; an attempt to understand the molecular architecture of the emitter site.

    Science.gov (United States)

    Salehi, Farajollah; Emamzadeh, Rahman; Nazari, Mahboobeh; Rasa, Seyed Mohammad Mahdi

    2016-12-01

    Renilla luciferase is a sensitive enzyme and has wide applications in biotechnology such as drug screening. Previous studies have tried to show the catalytic residues, nevertheless, the accurate architecture and molecular behavior of its emitter site remains uncharacterized. In this study, the activity of Renilla luciferase, in the presence of two small organic molecules including dimethyl sulfoxide (DMSO) and isopropanol was considered and the structure was studied by circular dichroism (CD) and fluorescence spectroscopy. Moreover, the interaction of small organic molecules with the Renilla luciferase was studied using molecular dynamics simulations. Kinetics studies showed that at low concentration of DMSO (16.6-66mM) and isopropanol (19.3-76mM) the K m changed and a competitive inhibition pattern was observed. Moreover, spectroscopy studies reveled that the changes of activity of Renilla luciferase in the presence of low concentrations of small organic molecules was not associated with structural collapse or severe changes in the enzyme conformation. Molecular dynamics simulations indicated that DMSO and isopropanol, as probing molecules, were both able to bind to the emitter site and remained with the residues of the emitter site. Based on the probing data, the architecture of the emitter site in the "non-binding" model was proposed. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Does CEO compensation impact patient satisfaction?

    Science.gov (United States)

    Akingbola, Kunle; van den Berg, Herman A

    2015-01-01

    This study examines the relationship between CEO compensation and patient satisfaction in Ontario, Canada. The purpose of this paper is to determine what impact hospital CEO compensation has on hospital patient satisfaction. The analyses in this study were based on data of 261 CEO-hospital-year observations in a sample of 103 nonprofit hospitals. A number of linear regressions were conducted, with patient satisfaction as the dependent variable and CEO compensation as the independent variable of interest. Controlling variables included hospital size, type of hospital, and frequency of adverse clinical outcomes. CEO compensation does not significantly influence hospital patient satisfaction. Both patient satisfaction and CEO compensation appear to be driven primarily by hospital size. Patient satisfaction decreases, while CEO compensation increases, with the number of acute care beds in a hospital. In addition, CEO compensation does not even appear to moderate the influence of hospital size on patient satisfaction. There are several limitations to this study. First, observations of CEO-hospital-years in which annual nominal CEO compensation was below $100,000 were excluded, as they were not publicly available. Second, this research was limited to a three-year range. Third, this study related the compensation of individual CEOs to a measure of performance based on a multitude of patient satisfaction surveys. Finally, this research is restricted to not-for-profit hospitals in Ontario, Canada. The findings seem to suggest that hospital directors seeking to improve patient satisfaction may find their efforts frustrated if they focus exclusively on the hospital CEO. The findings highlight the need for further research on how CEOs may, through leading and supporting those hospital clinicians and staff that interact more closely with patients, indirectly enhance patient satisfaction. To the best of the authors' knowledge, no research has examined the relationship between

  19. US-LHC IR magnet error analysis and compensation

    International Nuclear Information System (INIS)

    Wei, J.; Ptitsin, V.; Pilat, F.; Tepikian, S.; Gelfand, N.; Wan, W.; Holt, J.

    1998-01-01

    This paper studies the impact of the insertion-region (IR) magnet field errors on LHC collision performance. Compensation schemes including magnet orientation optimization, body-end compensation, tuning shims, and local nonlinear correction are shown to be highly effective

  20. The relationship between South African CEO compensation and ...

    African Journals Online (AJOL)

    1A study of corporate financial performance and CEO compensation by Firth, Lohne,. Ropstad .... requires both a qualitative and quantitative analysis. REMCOs, in ...... 'Executive compensation as an agency problem', Journal of. Economic ...

  1. Feasibility Study of Schottky Emitter Arrays

    NARCIS (Netherlands)

    Dokania, A.K.

    2010-01-01

    In this thesis an attempt is made to make a step forward in the development of next a generation scanning electron lithography machine for sub 25nm chip making. One of the challenges for such a system is to have sufficient beam-lets with enough current for parallel writing which requires a

  2. Effectiveness of Emittance Bumps in the NLC and US Cold LC Main Linear Accelerators (LCC-0138)

    International Nuclear Information System (INIS)

    Tenenbaum, P

    2004-01-01

    We report on a series of studies on the effectiveness of closed orbit bumps in the linacs of the NLC and the USColdLC. In the first study, emittance dilutions of a pure-wakefield or pure-dispersion character are introduced in each linac, and a set of emittance bumps is tested to determine the most effective bump location in the linac, and the net effectiveness. In the second study, a more realistic set of dilutions are introduced and the wakefield bumps used in the first study are applied

  3. Dynamical theory of single-photon transport in a one-dimensional waveguide coupled to identical and nonidentical emitters

    Science.gov (United States)

    Liao, Zeyang; Nha, Hyunchul; Zubairy, M. Suhail

    2016-11-01

    We develop a general dynamical theory for studying a single-photon transport in a one-dimensional (1D) waveguide coupled to multiple emitters which can be either identical or nonidentical. In this theory, both the effects of the waveguide and non-waveguide vacuum modes are included. This theory enables us to investigate the propagation of an emitter excitation or an arbitrary single-photon pulse along an array of emitters coupled to a 1D waveguide. The dipole-dipole interaction induced by the non-waveguide modes, which is usually neglected in the literature, can significantly modify the dynamics of the emitter system as well as the characteristics of the output field if the emitter separation is much smaller than the resonance wavelength. Nonidentical emitters can also strongly couple to each other if their energy difference is less than or of the order of the dipole-dipole energy shift. Interestingly, if their energy difference is close but nonzero, a very narrow transparency window around the resonance frequency can appear which does not occur for identical emitters. This phenomenon may find important applications in quantum waveguide devices such as optical switches and ultranarrow single-photon frequency comb generator.

  4. High brightness fiber laser pump sources based on single emitters and multiple single emitters

    Science.gov (United States)

    Scheller, Torsten; Wagner, Lars; Wolf, Jürgen; Bonati, Guido; Dörfel, Falk; Gabler, Thomas

    2008-02-01

    Driven by the potential of the fiber laser market, the development of high brightness pump sources has been pushed during the last years. The main approaches to reach the targets of this market had been the direct coupling of single emitters (SE) on the one hand and the beam shaping of bars and stacks on the other hand, which often causes higher cost per watt. Meanwhile the power of single emitters with 100μm emitter size for direct coupling increased dramatically, which also pushed a new generation of wide stripe emitters or multi emitters (ME) of up to 1000μm emitter size respectively "minibars" with apertures of 3 to 5mm. The advantage of this emitter type compared to traditional bars is it's scalability to power levels of 40W to 60W combined with a small aperture which gives advantages when coupling into a fiber. We show concepts using this multiple single emitters for fiber coupled systems of 25W up to 40W out of a 100μm fiber NA 0.22 with a reasonable optical efficiency. Taking into account a further efficiency optimization and an increase in power of these devices in the near future, the EUR/W ratio pushed by the fiber laser manufacturer will further decrease. Results will be shown as well for higher power pump sources. Additional state of the art tapered fiber bundles for photonic crystal fibers are used to combine 7 (19) pump sources to output powers of 100W (370W) out of a 130μm (250μm) fiber NA 0.6 with nominal 20W per port. Improving those TFB's in the near future and utilizing 40W per pump leg, an output power of even 750W out of 250μm fiber NA 0.6 will be possible. Combined Counter- and Co-Propagated pumping of the fiber will then lead to the first 1kW fiber laser oscillator.

  5. A compensating point defect in carbon-doped GaN substrates studied with electron paramagnetic resonance spectroscopy

    Science.gov (United States)

    Willoughby, W. R.; Zvanut, M. E.; Paudel, Subash; Iwinska, M.; Sochacki, T.; Bockowski, M.

    2018-04-01

    Electron paramagnetic resonance (EPR) spectroscopy was used to investigate a type of point defect present in 1019 cm-3 carbon-doped GaN substrates grown by hydride vapor phase epitaxy. A broad, isotropic resonance at g ˜ 1.987 was observed at 3.5 K, and the EPR intensity increased with illumination at energies greater than 2.75 eV and decreased with photon energies greater than 0.95 eV. The latter is consistent with a deep level of 0.95 eV above the valence band maximum and implies that the associated defect likely participates in donor compensation. The ionization energy for this defect is close to the predicted value for the (-/0) transition level of CN and transition levels associated with Ga vacancies such as VGa and VGa-ON-2H.

  6. Finite-element modeling of spontaneous emission of a quantum emitter at nanoscale proximity to plasmonic waveguides

    DEFF Research Database (Denmark)

    Chen, Yuntian; Nielsen, Torben Roland; Gregersen, Niels

    2010-01-01

    of the plasmonic waveguide can be arbitrary. The fraction of the energy coupled to the plasmonic mode can be calculated exactly, which can be used to determine the efficiency with which single optical plasmons are generated. We apply our numerical method to calculate the coupling of a quantum emitter......We develop a self-consistent finite-element method to quantitatively study spontaneous emission from emitters in nanoscale proximity of plasmonic waveguides. In the model, it is assumed that only one guided mode is dominatingly excited by the quantum emitter, while the cross section...

  7. Internal dynamics and emittance growth in space-charge-dominated beams

    International Nuclear Information System (INIS)

    Anderson, O.A.

    1987-01-01

    Previous analytical studies have related transverse rms emittance growth in nonuniform beams to changes in the beam density profile, but the time evolution of the process has not been analyzed. Our new approach analyzes the internal motion of the beam and from this obtains the explicit time dependence of the rms emittance. It is shown to reach its peak value explosively in about one quarter of a plasma period. The subsequent behavior depends on the uniformity of the initial density profile. We derive a uniformity criterion that determines whether or not the emittance oscillates periodically and present examples of density profiles for which the emittance returns to its initial value and then continues to oscillate. We discuss a class of continuous initial profiles that lead to discontinuous shocklike behavior (with partial irreversibility of the oscillations) and a class of segmented profiles for which the emittance jumps to its maximum value in one fourth of a plasma period and remains at that value with essentially no further change. (author)

  8. Plexciton quenching by resonant electron transfer from quantum emitter to metallic nanoantenna.

    Science.gov (United States)

    Marinica, D C; Lourenço-Martins, H; Aizpurua, J; Borisov, A G

    2013-01-01

    Coupling molecular excitons and localized surface plasmons in hybrid nanostructures leads to appealing, tunable optical properties. In this respect, the knowledge about the excitation dynamics of a quantum emitter close to a plasmonic nanoantenna is of importance from fundamental and practical points of view. We address here the effect of the excited electron tunneling from the emitter into a metallic nanoparticle(s) in the optical response. When close to a plasmonic nanoparticle, the excited state localized on a quantum emitter becomes short-lived because of the electronic coupling with metal conduction band states. We show that as a consequence, the characteristic features associated with the quantum emitter disappear from the optical absorption spectrum. Thus, for the hybrid nanostructure studied here and comprising quantum emitter in the narrow gap of a plasmonic dimer nanoantenna, the quantum tunneling might quench the plexcitonic states. Under certain conditions the optical response of the system approaches that of the individual plasmonic dimer. Excitation decay via resonant electron transfer can play an important role in many situations of interest such as in surface-enhanced spectroscopies, photovoltaics, catalysis, or quantum information, among others.

  9. Counter-rotating effects and entanglement dynamics in strongly coupled quantum-emitter-metallic-nanoparticle structures

    Science.gov (United States)

    Iliopoulos, Nikos; Thanopulos, Ioannis; Yannopapas, Vassilios; Paspalakis, Emmanuel

    2018-03-01

    We study the spontaneous emission of a two-level quantum emitter next to a plasmonic nanoparticle beyond the Markovian approximation and the rotating-wave approximation (RWA) by combining quantum dynamics and classical electromagnetic calculations. For emitters with decay times in the picosecond to nanosecond time regime, as well as located at distances from the nanoparticle up to its radius, the dynamics with and without the RWA and the transition from the non-Markovian to the Markovian regime are investigated. For emitters with longer decay times, the Markov approximation proves to be adequate for distances larger than half the nanoparticle radius. However, the RWA is correct for all distances of the emitter from the nanoparticle. For short decay time emitters, the Markov approximation and RWA are both inadequate, with only the RWA becoming valid again at a distance larger than half the nanoparticle radius. We also show that the entanglement dynamics of two initially entangled qubits interacting independently with the nanoparticle may have a strong non-Markovian character when counter-rotating effects are included. Interesting effects such as entanglement sudden death, periodic entanglement revival, entanglement oscillations, and entanglement trapping are further observed when different initial two-qubit states and different distances between the qubit and the nanoparticle are considered.

  10. The Quantum Efficiency and Thermal Emittance of Metal Photocathodes

    International Nuclear Information System (INIS)

    Dowell, D.

    2009-01-01

    Modern electron beams have demonstrated the brilliance needed to drive free electron lasers at x-ray wavelengths, with the principle improvements occurring since the invention of the photocathode gun. The state-of-the-art normalized emittance electron beams are now becoming limited by the thermal emittance of the cathode. In both DC and RF photocathode guns, details of the cathode emission physics strongly influence the quantum efficiency and the thermal emittance. Therefore improving cathode performance is essential to increasing the brightness of beams. It is especially important to understand the fundamentals of cathode quantum efficiency and thermal emittance. This paper investigates the relationship between the quantum efficiency and the thermal emittance of metal cathodes using the Fermi-Dirac model for the electron distribution. We derive the thermal emittance and its relationship to the quantum efficiency, and compare our results to those of others

  11. Effects of emittance and space-charge in femtosecond bunch compression

    International Nuclear Information System (INIS)

    Kan, K.; Yang, J.; Kondoh, T.; Norizawa, K.; Yoshida, Y.

    2008-01-01

    Ultrashort electron bunches of the order of <100fs are essential for the study of ultrafast reactions and phenomena by means of time-resolved pump-probe experiments. In order to generate such an electron bunch, the effects of emittance, space-charge (SC) and coherent synchrotron radiation (CSR) on the bunch length in a femtosecond magnetic bunch compressor were studied theoretically. It was observed that the bunch length is dominated by the emittance, SC and CSR effects when the electron bunch is compressed into a femtosecond electron bunch. The increases in bunch length due to the transverse emittance, SC and CSR effects in the bunch compressor were 1.7 fs/mm mrad, 107 fs/nC and 72 fs/nC, respectively. Finally, the simulated bunch length was compared with the experimental results.

  12. Emittance measurement and modeling for the Fermilab Booster

    Directory of Open Access Journals (Sweden)

    Xiaobiao Huang

    2006-01-01

    Full Text Available Turn-by-turn beam profile data measured at the Fermilab Booster are studied. Lattice models with experimental accelerator ramping parameters are used to obtain the lattice functions for data analysis. We studied the horizontal and vertical emittance growth behavior in different stages of a booster ramping cycle and its relation to the beam intensity. The transverse and longitudinal components in the horizontal beam width are separated by a fitting model which makes use of the different scaling rules of the beam momentum. We analyze the post-transition horizontal beam size oscillation based on a model where the longitudinal phase-space mismatch has resulted from rf voltage mismatch during the transition-energy crossing. We carried out systematic multiparticle simulation to show that the source of the vertical emittance growth is a combination of the random errors in skew-quadrupole and dipole fields, and the systematic Montague resonance. The effect of random quadrupole field is small for the Fermilab Booster because the betatron envelope tunes are reasonably far away from the half-integer stop band.

  13. Rayleigh scattering in an emitter-nanofiber-coupling system

    Science.gov (United States)

    Tang, Shui-Jing; Gao, Fei; Xu, Da; Li, Yan; Gong, Qihuang; Xiao, Yun-Feng

    2017-04-01

    Scattering is a general process in both fundamental and applied physics. In this paper, we investigate Rayleigh scattering of a solid-state-emitter coupled to a nanofiber, by S -matrix-like theory in k -space description. Under this model, both Rayleigh scattering and dipole interaction are studied between a two-level artificial atom embedded in a nanocrystal and fiber modes (guided and radiation modes). It is found that Rayleigh scattering plays a critical role in the transport properties and quantum statistics of photons. On the one hand, Rayleigh scattering produces the transparency in the optical transmitted field of the nanofiber, accompanied by the change of atomic phase, population, and frequency shift. On the other hand, the interference between two kinds of scattering fields by Rayleigh scattering and dipole transition modifies the photon statistics (second-order autocorrelation function) of output fields, showing a strong wavelength dependence. This study provides guidance for the solid-state emitter acting as a single-photon source and can be extended to explore the scattering effect in many-body physics.

  14. Investigations on cermet electrodes for thermionic emitters

    International Nuclear Information System (INIS)

    Schmidt, D.; Nazare, S.

    1975-01-01

    Unstable Ba 2 CaWO 6 -W with their own supply of Ba, as well as stable UO 2 -Mo-emitter cermets that have to be operated with an external Ba-source, have been prepared by axial hot pressing. The relevant properties of these cermets such as electrical resistivity and thermal expansion are reported and compared with theoretical predictions. The electron emission of these materials is discussed on the basis of the surface films formed. It provides the basis for optimising the behavior of these materials

  15. Multi-channel polarized thermal emitter

    Science.gov (United States)

    Lee, Jae-Hwang; Ho, Kai-Ming; Constant, Kristen P

    2013-07-16

    A multi-channel polarized thermal emitter (PTE) is presented. The multi-channel PTE can emit polarized thermal radiation without using a polarizer at normal emergence. The multi-channel PTE consists of two layers of metallic gratings on a monolithic and homogeneous metallic plate. It can be fabricated by a low-cost soft lithography technique called two-polymer microtransfer molding. The spectral positions of the mid-infrared (MIR) radiation peaks can be tuned by changing the periodicity of the gratings and the spectral separation between peaks are tuned by changing the mutual angle between the orientations of the two gratings.

  16. High efficiency quasi-monochromatic infrared emitter

    Energy Technology Data Exchange (ETDEWEB)

    Brucoli, Giovanni; Besbes, Mondher; Benisty, Henri, E-mail: henri.benisty@institutoptique.fr; Greffet, Jean-Jacques [Laboratoire Charles Fabry, UMR 8501, Institut d’Optique, CNRS, Université Paris-Sud 11, 2, Avenue Augustin Fresnel, 91127 Palaiseau Cedex (France); Bouchon, Patrick; Haïdar, Riad [Office National d’Études et de Recherches Aérospatiales, Chemin de la Hunière, 91761 Palaiseau (France)

    2014-02-24

    Incandescent radiation sources are widely used as mid-infrared emitters owing to the lack of alternative for compact and low cost sources. A drawback of miniature hot systems such as membranes is their low efficiency, e.g., for battery powered systems. For targeted narrow-band applications such as gas spectroscopy, the efficiency is even lower. In this paper, we introduce design rules valid for very generic membranes demonstrating that their energy efficiency for use as incandescent infrared sources can be increased by two orders of magnitude.

  17. Longitudinal emittance measurement at the ATS

    International Nuclear Information System (INIS)

    Cottingame, W.B.; Cortez, J.H.; Higgins, W.W.; Sander, O.R.; Sandoval, D.P.

    1986-01-01

    With increasing brightness, beam diagnostic techniques requiring interception of the beam become impractical. For H - particle beams, solutions for this problem based on the phenomenon of photodissociation are now being investigated at the Los Alamos National Laboratory accelerator test stand (ATS). A laser can be used to selectively neutralize portions of the beam than can be characterized after the charged particles have been swept away. We have used this technique for measuring longitudinal emittance at the output of the ATS radio-frequency quadrupole

  18. Emittance growth from transient coherent synchrotron radiation

    International Nuclear Information System (INIS)

    Bohn, C.L.; Li, R.; Bisognano, J.J.

    1996-01-01

    If the energies of individual particles in a bunch change as the bunch traverses a bending system, even if it is achromatic, betatron oscillations can be excited. Consequently, the transverse emittance of the bunch will grow as it moves downstream. Short bunches may be particularly susceptible to emission of coherent synchrotron radiation which can act back on the particles to change their energies and trajectories. Because a bend spans a well-defined length and angle, the bunch-excited wakefield and its effect back on the bunch are inherently transient. We outline a recently developed theory of this effect and apply it to example bending systems

  19. Tolerances for the vertical emittance in damping rings

    International Nuclear Information System (INIS)

    Raubenheimer, T.O.

    1991-11-01

    Future damping rings for linear colliders will need to have very small vertical emittances. In the limit of low beam current, the vertical emittance is primarily determined by the vertical dispersion and the betatron coupling. In this paper, the contributions to these effects from random misalignments are calculated and tolerances are derived to limit the vertical emittance with a 95% confidence level. 10 refs., 5 figs

  20. Emittance calculations for the Stanford Linear Collider injector

    International Nuclear Information System (INIS)

    Sheppard, J.C.; Clendenin, J.E.; Helm, R.H.; Lee, M.J.; Miller, R.H.; Blocker, C.A.

    1983-03-01

    A series of measurements have been performed to determine the emittance of the high intensity, single bunch beam that is to be injected into the Stanford Linear Collider. On-line computer programs were used to control the Linac for the purpose of data acquisition and to fit the data to a model in order to deduce the beam emittance. This paper will describe the method of emittance calculation and present some of the measurement results

  1. Measurement of emittance of metal interface in molten salt

    International Nuclear Information System (INIS)

    Araki, N.; Makino, A.; Nakamura, Y.

    1995-01-01

    A new technique for measuring the total normal emittance of a metal in a semi-transparent liquid has been proposed and this technique has been applied to measure the emittance of stainless steel (SUS304), nickel, and gold in molten potassium nitrate KNO 3 . These emittance data are indispensable to analyzing the radiative heat transfer between a metal and a semitransparent liquid, such as a molten salt

  2. Development and application of an emitter for research of an on-board ultraviolet polarimeter

    Science.gov (United States)

    Nevodovskyi, P. V.; Geraimchuk, M. D.; Vidmachenko, A. P.; Ivakhiv, O. V.

    2018-05-01

    In carrying out of the work a layout of on-board small-sized ultraviolet polarimeter (UVP) was created. UVP is the device, which provides an implementation of passive remote studies of stratospheric aerosol from the board of the microsatellite of the Earth by the method of polarimetry. For carrying out of tests and the research of polarimetric equipment, a special stand was created at MAO of NAS of Ukraine. In its composition is an ultraviolet emitter. Emitter is one of the main components of a special stand for the study of on-board ultraviolet polarimeters.

  3. Non-stochastic effects of different energy beta emitters on pig and mouse skin

    International Nuclear Information System (INIS)

    Peel, D.M.; Hopewell, J.W.; Hansen, L.S.; Coggle, J.E.; Charles, M.W.; Wells, J.

    1982-01-01

    In this collaborative study skin areas of various sizes were irradiated with different energy beta emitters. In the post-irradiation period fields were examined for erythema, desquamation, ulceration and dermal necrosis. The aim of the study is to determine the threshold doses for the different biological reactions as a function of the energy of the radiation and the size of skin field irradiated. At St. Bartholomew's Hospital and Oxford the irradiation of mouse and pig skin was carried out using strontium-90 and thulium-170 sources. In addition, mice were irradiated with thallium-204, a slightly lower energy beta emitter than thulium. (author)

  4. Assessment of Wetland Valuation Processes for Compensation in ...

    African Journals Online (AJOL)

    The issue of compensation has been debated in various fora; however compensation on wetland resources has not been given the primary place. Wetland valuation like any other type of valuation requires going through stages, which may be more complex than real estate valuation for compensation. This study therefore ...

  5. Performance of Leak Compensation in All-Age ICU Ventilators During Volume-Targeted Neonatal Ventilation: A Lung Model Study.

    Science.gov (United States)

    Itagaki, Taiga; Bennett, Desmond J; Chenelle, Christopher T; Fisher, Daniel F; Kacmarek, Robert M

    2017-01-01

    Volume-targeted ventilation is increasingly used in low birthweight infants because of the potential for reducing volutrauma and avoiding hypocapnea. However, it is not known what level of air leak is acceptable during neonatal volume-targeted ventilation when leak compensation is activated concurrently. Four ICU ventilators (Servo-i, PB980, V500, and Avea) were compared in available invasive volume-targeted ventilation modes (pressure control continuous spontaneous ventilation [PC-CSV] and pressure control continuous mandatory ventilation [PC-CMV]). The Servo-i and PB980 were tested with (+) and without (-) their proximal flow sensor. The V500 and Avea were tested with their proximal flow sensor as indicated by their manufacturers. An ASL 5000 lung model was used to simulate 4 neonatal scenarios (body weight 0.5, 1, 2, and 4 kg). The ASL 5000 was ventilated via an endotracheal tube with 3 different leaks. Two minutes of data were collected after each change in leak level, and the asynchrony index was calculated. Tidal volume (V T ) before and after the change in leak was assessed. The differences in delivered V T between before and after the change in leak were within ±5% in all scenarios with the PB980 (-/+) and V500. With the Servo-i (-/+), baseline V T was ≥10% greater than set V T during PC-CSV, and delivered V T markedly changed with leak. The Avea demonstrated persistent high V T in all leak scenarios. Across all ventilators, the median asynchrony index was 1% (interquartile range 0-27%) in PC-CSV and 1.8% (0-45%) in PC-CMV. The median asynchrony index was significantly higher in the Servo-i (-/+) than in the PB980 (-/+) and V500 in 1 and 2 kg scenarios during PC-CSV and PC-CMV. The PB980 and V500 were the only ventilators to acclimate to all leak scenarios and achieve targeted V T . Further clinical investigation is needed to validate the use of leak compensation during neonatal volume-targeted ventilation. Copyright © 2017 by Daedalus Enterprises.

  6. Transverse beam emittance optimization for the injection into BESSY II

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, Felix [Helmholtz Zentrum Berlin, Institut Beschleunigerphysik (Germany); Humboldt-Universitaet zu Berlin, Institut fuer Physik (Germany)

    2016-07-01

    For top up injection into the storage ring BESSY II an average injection efficiency of at least 90% is required. In low alpha mode the injection efficiency does not meet the requirements. Future BESSY II features will include shorter bunches in the storage ring (VSR) and user transparent injection with a non linear kicker. These will raise the demands on the quality of the injected beam even further. This work investigates the development of transverse emittance over the acceleration cycle in the synchrotron and the possibility of transverse emittance exchange by a sequence of skew quadrupoles in the transfer line. Results of emittance measurements and emittance exchange simulations will be given.

  7. Emittance Growth during Bunch Compression in the CTF-II

    Energy Technology Data Exchange (ETDEWEB)

    Raubenheimer, Tor O

    1999-02-26

    Measurements of the beam emittance during bunch compression in the CLIC Test Facility (CTF-II) are described. The measurements were made with different beam charges and different energy correlations versus the bunch compressor settings which were varied from no compression through the point of full compression and to over-compression. Significant increases in the beam emittance were observed with the maximum emittance occurring near the point of full (maximal) compression. Finally, evaluation of possible emittance dilution mechanisms indicate that coherent synchrotron radiation was the most likely cause.

  8. Exploring the importance of different items as reasons for leaving emergency medical services between fully compensated, partially compensated, and non-compensated/volunteer samples.

    Science.gov (United States)

    Blau, Gary; Chapman, Susan; Gibson, Gregory; Bentley, Melissa A

    2011-01-01

    The purpose of our study was to investigate the importance of different items as reasons for leaving the Emergency Medical Service (EMS) profession. An exit survey was returned by three distinct EMS samples: 127 full compensated, 45 partially compensated and 72 non-compensated/volunteer respondents, who rated the importance of 17 different items for affecting their decision to leave EMS. Unfortunately, there were a high percentage of "not applicable" responses for 10 items. We focused on those seven items that had a majority of useable responses across the three samples. Results showed that the desire for better pay and benefits was a more important reason for leaving EMS for the partially compensated versus fully compensated respondents. Perceived lack of advancement opportunity was a more important reason for leaving for the partially compensated and volunteer groups versus the fully compensated group. Study limitations are discussed and suggestions for future research offered.

  9. Aeromagnetic Compensation for UAVs

    Science.gov (United States)

    Naprstek, T.; Lee, M. D.

    2017-12-01

    Aeromagnetic data is one of the most widely collected types of data in exploration geophysics. With the continuing prevalence of unmanned air vehicles (UAVs) in everyday life there is a strong push for aeromagnetic data collection using UAVs. However, apart from the many political and legal barriers to overcome in the development of UAVs as aeromagnetic data collection platforms, there are also significant scientific hurdles, primary of which is magnetic compensation. This is a well-established process in manned aircraft achieved through a combination of platform magnetic de-noising and compensation routines. However, not all of this protocol can be directly applied to UAVs due to fundamental differences in the platforms, most notably the decrease in scale causing magnetometers to be significantly closer to the avionics. As such, the methodology must be suitably adjusted. The National Research Council of Canada has collaborated with Aeromagnetic Solutions Incorporated to develop a standardized approach to de-noising and compensating UAVs, which is accomplished through a series of static and dynamic experiments. On the ground, small static tests are conducted on individual components to determine their magnetization. If they are highly magnetic, they are removed, demagnetized, or characterized such that they can be accounted for in the compensation. Dynamic tests can include measuring specific components as they are powered on and off to assess their potential effect on airborne data. The UAV is then flown, and a modified compensation routine is applied. These modifications include utilizing onboard autopilot current sensors as additional terms in the compensation algorithm. This process has been applied with success to fixed-wing and rotary-wing platforms, with both a standard manned-aircraft magnetometer, as well as a new atomic magnetometer, much smaller in scale.

  10. Photophysics of GaN single-photon emitters in the visible spectral range

    Science.gov (United States)

    Berhane, Amanuel M.; Jeong, Kwang-Yong; Bradac, Carlo; Walsh, Michael; Englund, Dirk; Toth, Milos; Aharonovich, Igor

    2018-04-01

    In this work, we present a detailed photophysical analysis of recently discovered, optically stable single-photon emitters (SPEs) in gallium nitride (GaN). Temperature-resolved photoluminescence measurements reveal that the emission lines at 4 K are three orders of magnitude broader than the transform-limited width expected from excited-state lifetime measurements. The broadening is ascribed to ultrafast spectral diffusion. The photophysical study on several emitters at room temperature (RT) reveals an average brightness of (427 ±215 )kCounts /s . Finally, polarization measurements from 14 emitters are used to determine visibility as well as dipole orientation of defect systems within the GaN crystal. Our results underpin some of the fundamental properties of SPEs in GaN both at cryogenic and RT, and define the benchmark for future work in GaN-based single-photon technologies.

  11. Emittance growth in displaced, space-charge-dominated beams with energy spread

    International Nuclear Information System (INIS)

    Barnard, J.J.; Miller, J.; Haber, I.

    1993-01-01

    Conversion of transverse energy associated with the coherent motion of displaced beams into thermal energy, and thus emittance growth, has been predicted theoretically by a number of authors. Here, they authors show, using 2-D particle-in-cell simulations, that emittance growth is inhibited for tune depressed beams, if the energy spread of the beam is not too large. Further, using a uniform density model to calculate the space charge field of the beam, they numerically determine the criteria for emittance growth as a function of tune depression, energy spread, and beam displacement over a wide range of parameters. A theoretical interpretation of the results is presented. This study is applicable to an inertial fusion reactor driven by a heavy ion accelerator

  12. Emittance simulation for a different electron bunch charges with upgraded PITZ setup

    Energy Technology Data Exchange (ETDEWEB)

    Vashchenko, Grygorii [DESY, Platanenallee 6, 15738 Zeuthen (Germany)

    2013-07-01

    The photo injector test facility at DESY, Zeuthen site (PITZ) was invented with an aim to develop, characterize and optimize the electron sources for linac driven free electron lasers like FLASH and European XFEL. As a prerequisite for a successful experimental emittance optimization, emittance dependencies on the majority of linac parameters have to be studied in simulations. Despite that the nominal electron bunch charge for the operation of FLASH and XFEL is 1nC, there is an interest of the community to operate with other bunch charges. Emittance dependencies on such machine parameters like laser spot size on the photo cathode, laser pulse length, gun launching phase, focusing solenoid current and first accelerating structure gradient are simulated for different electron bunch charges. Based on the simulations data the systematic errors caused by detuning of the different machine parameters from their optimum values are estimated.

  13. Compensation Techniques in Accelerator Physics

    Energy Technology Data Exchange (ETDEWEB)

    Sayed, Hisham Kamal [Old Dominion Univ., Norfolk, VA (United States)

    2011-05-01

    Accelerator physics is one of the most diverse multidisciplinary fields of physics, wherein the dynamics of particle beams is studied. It takes more than the understanding of basic electromagnetic interactions to be able to predict the beam dynamics, and to be able to develop new techniques to produce, maintain, and deliver high quality beams for different applications. In this work, some basic theory regarding particle beam dynamics in accelerators will be presented. This basic theory, along with applying state of the art techniques in beam dynamics will be used in this dissertation to study and solve accelerator physics problems. Two problems involving compensation are studied in the context of the MEIC (Medium Energy Electron Ion Collider) project at Jefferson Laboratory. Several chromaticity (the energy dependence of the particle tune) compensation methods are evaluated numerically and deployed in a figure eight ring designed for the electrons in the collider. Furthermore, transverse coupling optics have been developed to compensate the coupling introduced by the spin rotators in the MEIC electron ring design.

  14. Review of studies validating the protective efficacy of a new technology designed to compensate adverse biological effects caused by vdu and GSM cell phone radiation

    International Nuclear Information System (INIS)

    Youbicier-Simo, B.J.; Messagier, R.; Fillion-Robin, M

    2001-01-01

    A total of 13 studies were initiated and coordinated by Technolab Research Center in 6 laboratories from 3 countries (France, UK, Japan). These studies were aimed at: 1) investigating potential adverse biological effects associated with exposure to non ionizing radiation emitted by two types of communication devices, video display units and cell phones; 2) assessing the efficacy of a compensation magnetic oscillating technology designed to protect from non ionizing radiation. Five types of biological systems including chicken embryos, young chickens, healthy mice, mice suffering from cancer and humans were used. A set of 10 biological parameters were assessed, including embryonic mortality, hormones, antibodies, haematological parameters, stress, mood, ocular damage, neurogenesis, micronuclei formation and intracellular calcium. Overall endpoints were affected by irradiation, in terms of increased embryonic mortality, immune depression, depletion of hormones crucial for the regulation of the immune system, changes in haematological parameters, increased stress, mood alteration, induction of ophthalmologic disorders, inhibition of the neurogenesis in brain areas associated with memory processes, induction of symptoms of cell dysfunction, apoptosis or cancer, and disruption of trans-membrane fluxes of calcium. On the other hand, the compensation magnetic oscillation technology tested allowed significant correction of altered physiological parameters, as well as improvement or disappearance of observed pathological symptoms (author)

  15. Comparative Study of Determining of the Responsible Person and the Basis of Compensation in Civil Liability Results from Events Related to Nuclear Facilities

    Directory of Open Access Journals (Sweden)

    Sayyed Mohammad Mahdi Qabuli Dorafshan

    2015-12-01

    Full Text Available Nuclear facilities, though have large advantages for human being, they also creates heavy hazards. Thus, the question of civil liability results from events of mentioned facilities are so significant. This paper studies the question of the basis and responsible for compensation results from aforementioned events in international instruments, Iran and French law. Outcome of this study shows that in this regard, Paris and Vienna conventions and the other related conventions and protocols adjust a special legal régime. In this respect, the international instruments while distancing themselves from liability based on fault, highlight the exclusive responsibility of the operator of nuclear facilities and they have commited the operator to insurance or appropriate secure financing. Also French legal régime have followed this manner with the impact of the Paris Convention and its amendments and additions. There is no special provisions in Iran legal régime in this matter so civil liability results from nuclear events is under general rules of civil liability and rules such Itlaf (loss, Tasbib (causation, Taqsir (fault and La-zarar (no damage in the context of Imamye jurisprudence. Ofcourse, the responsible is basically the one who the damage is attributable to him. Finaly, It is appropriate that the Iranian legislator predict favorable régime and provides special financial fund for compensation of possible injured parties in accordance with necessities and specific requirements related to nuclear energy

  16. A positron annihilation study of compensation defects responsible for conduction-type conversions in LEC-grown InP

    International Nuclear Information System (INIS)

    Shan, Y.Y.; Ling, C.C.; Fung, S.; Beling, C.D.; Zhao, Y.W.

    2001-01-01

    Positron annihilation techniques have been employed to investigate the formation of vacancy type of compensation defects in undoped LEC-grown InP. N-type InP becomes p-type semiconducting by short time annealing at 700 C, and then turns to be n-type again after further annealing but with a much higher resistivity. Positron lifetime measurements show that the positron average lifetime τ av increases to a high value of 247ps for the first n-type to p-type conversion and decreases to 240ps for the following p-type to n-type conversion. τ av increases slightly and saturates at 242ps upon further annealing. The results of positron annihilation Doppler-broadening measurements are consistent with the positron lifetime measurements. The correlation between the characteristics of positron annihilation and the conversions of conduction type indicates that the formation of vacancy type defects and the progressive variation of their concentrations during annealing are critical to the electrical properties of the bulk InP material. (orig.)

  17. An fMRI Study of Nonverbally Gifted Reading Disabled Adults: Has Deficit Compensation Effected Gifted Potential?

    Directory of Open Access Journals (Sweden)

    Jeffrey W Gilger

    2013-08-01

    Full Text Available Neuroscience has advanced our understanding of the neurological basis of reading disability. Yet, no functional imaging work has been reported on the twice-exceptional dyslexic: individuals exhibiting both nonverbal-giftedness and reading disability (RD. We compared groups of reading-disabled (RD, nonverbally-gifted (G, nonverbally-gifted-RD (GRD, and control (C adults on validated word-rhyming and spatial visualization fMRI tasks, and standardized psychometric tests, to ascertain if the neurological functioning of GRD subjects was similar to that of typical RD or G subjects, or perhaps some unique RD subtype. Results demonstrate that GRD adults resemble non-gifted reading disabled (RD adults in performance on paper-and-pencil reading, math and spatial tests, and in patterns of functional activation during rhyming and spatial processing. Data are consistent with what may be a shared etiology of reading disability and giftedness in GRD individuals that yields a lifespan interaction with reading compensation effects, modifying how their adult brain processes text and spatial stimuli.

  18. Mandatory Compensation to Commercial Agents upon Termination ...

    African Journals Online (AJOL)

    Kamil Abdu Oumer

    the compensation due to the agent upon the termination of the commercial .... Virginia School of Law Legal Studies Working Papers Series, Working Paper No. ..... grant up to a one year commission if they find the circumstances equitable.67 In.

  19. Dosimetry of internal emitters - quo vadis?

    International Nuclear Information System (INIS)

    Reddy, A.R.; Nagaratnam, A.; Jain, S.C.; Gupta, M.M.; Mehta, S.C.

    1999-01-01

    The dosimetry of internally administered radiopharmaceuticals in nuclear medicine procedures using MIRD formalisms and dosimetry in the case of intakes of radionuclides and ICRP methodology for the purpose of radiological protection are well established working practices. It should, however, be remembered that dose or dose coefficients calculated refer to a reference individual, defined in terms of a mathematical phantom established on the basis of certain biokinetic reference parameters. The reference individual represents a typical caucasian adult of West Europe or North American origin. Recently, some attempts have been made to define a Reference Asian and a Reference Indian individual and to assess the effects of anatomical differences and changes in the biokinetics of radiopharmaceuticals and other radionuclides in these different reference individuals on the estimation of dose and dose coefficients in relation to the intake of internal radionuclides. The assessment of doses to the embryo/fetus due to intake of radionuclides by pregnant women, local dose estimates, microdosimetry, radiobiology and radiation protection aspects relating to Auger electron emitters represent other areas of active research in the area of dosimetry of internal emitters. The present review summarises these different aspects of work. (orig.) [de

  20. Barium depletion in hollow cathode emitters

    International Nuclear Information System (INIS)

    Polk, James E.; Mikellides, Ioannis G.; Katz, Ira; Capece, Angela M.

    2016-01-01

    Dispenser hollow cathodes rely on a consumable supply of Ba released by BaO-CaO-Al 2 O 3 source material in the pores of a tungsten matrix to maintain a low work function surface. The examination of cathode emitters from long duration tests shows deposits of tungsten at the downstream end that appear to block the flow of Ba from the interior. In addition, a numerical model of Ba transport in the cathode plasma indicates that the Ba partial pressure in the insert may exceed the equilibrium vapor pressure of the dominant Ba-producing reaction, and it was postulated previously that this would suppress Ba loss in the upstream part of the emitter. New measurements of the Ba depletion depth from a cathode insert operated for 8200 h reveal that Ba loss is confined to a narrow region near the downstream end, confirming this hypothesis. The Ba transport model was modified to predict the depletion depth with time. A comparison of the calculated and measured depletion depths gives excellent qualitative agreement, and quantitative agreement was obtained assuming an insert temperature 70 °C lower than measured beginning-of-life values

  1. Emittance growth of bunched beams in bends

    International Nuclear Information System (INIS)

    Carlsten, B.E.; Raubenheimer, T.O.

    1995-01-01

    Talman [Phys. Rev. Lett. 56, 1429 (1986)] has proposed a novel relativistic effect that occurs when a charged particle beam is bent in the magnetic field from an external dipole. The consequence of this effect is that the space-charge forces from the particles do not exhibit the usual inverse-square energy dependence and some part of them are, in fact, independent of energy. This led to speculation that this effect could introduce significant emittance growth for a bending electron beam. Subsequently, it was shown that this effect's influence on the beam's transverse motion is canceled for a dc beam by a potential depression within the beam (to first order in the beam radius divided by the bend radius). In this paper, we extend the analysis to include short bunch lengths (as compared to the beam pipe dimensions) and find that there is no longer the cancellation for forces both transverse to and in the direction of motion. We provide an estimate for the emittance growth as a function of bend angle, beam radius, and current, and for magnetic compression of an electron bunch

  2. Narrowband infrared emitters for combat ID

    Science.gov (United States)

    Pralle, Martin U.; Puscasu, Irina; Daly, James; Fallon, Keith; Loges, Peter; Greenwald, Anton; Johnson, Edward

    2007-04-01

    There is a strong desire to create narrowband infrared light sources as personnel beacons for application in infrared Identify Friend or Foe (IFF) systems. This demand has augmented dramatically in recent years with the reports of friendly fire casualties in Afghanistan and Iraq. ICx Photonics' photonic crystal enhanced TM (PCE TM) infrared emitter technology affords the possibility of creating narrowband IR light sources tuned to specific IR wavebands (near 1-2 microns, mid 3-5 microns, and long 8-12 microns) making it the ideal solution for infrared IFF. This technology is based on a metal coated 2D photonic crystal of air holes in a silicon substrate. Upon thermal excitation the photonic crystal modifies the emitted yielding narrowband IR light with center wavelength commensurate with the periodicity of the lattice. We have integrated this technology with microhotplate MEMS devices to yield 15mW IR light sources in the 3-5 micron waveband with wall plug efficiencies in excess of 10%, 2 orders of magnitude more efficient that conventional IR LEDs. We have further extended this technology into the LWIR with a light source that produces 9 mW of 8-12 micron light at an efficiency of 8%. Viewing distances >500 meters were observed with fielded camera technologies, ideal for ground to ground troop identification. When grouped into an emitter panel, the viewing distances were extended to 5 miles, ideal for ground to air identification.

  3. Compact Rare Earth Emitter Hollow Cathode

    Science.gov (United States)

    Watkins, Ronald; Goebel, Dan; Hofer, Richard

    2010-01-01

    A compact, high-current, hollow cathode utilizing a lanthanum hexaboride (LaB6) thermionic electron emitter has been developed for use with high-power Hall thrusters and ion thrusters. LaB6 cathodes are being investigated due to their long life, high current capabilities, and less stringent xenon purity and handling requirements compared to conventional barium oxide (BaO) dispenser cathodes. The new cathode features a much smaller diameter than previously developed versions that permit it to be mounted on axis of a Hall thruster ( internally mounted ), as opposed to the conventional side-mount position external to the outer magnetic circuit ("externally mounted"). The cathode has also been reconfigured to be capable of surviving vibrational loads during launch and is designed to solve the significant heater and materials compatibility problems associated with the use of this emitter material. This has been accomplished in a compact design with the capability of high-emission current (10 to 60 A). The compact, high-current design has a keeper diameter that allows the cathode to be mounted on the centerline of a 6- kW Hall thruster, inside the iron core of the inner electromagnetic coil. Although designed for electric propulsion thrusters in spacecraft station- keeping, orbit transfer, and interplanetary applications, the LaB6 cathodes are applicable to the plasma processing industry in applications such as optical coatings and semiconductor processing where reactive gases are used. Where current electrical propulsion thrusters with BaO emitters have limited life and need extremely clean propellant feed systems at a significant cost, these LaB6 cathodes can run on the crudest-grade xenon propellant available without impact. Moreover, in a laboratory environment, LaB6 cathodes reduce testing costs because they do not require extended conditioning periods under hard vacuum. Alternative rare earth emitters, such as cerium hexaboride (CeB6) can be used in this

  4. Anthropogenic Methane Emissions in California's San Joaquin Valley: Characterizing Large Point Source Emitters

    Science.gov (United States)

    Hopkins, F. M.; Duren, R. M.; Miller, C. E.; Aubrey, A. D.; Falk, M.; Holland, L.; Hook, S. J.; Hulley, G. C.; Johnson, W. R.; Kuai, L.; Kuwayama, T.; Lin, J. C.; Thorpe, A. K.; Worden, J. R.; Lauvaux, T.; Jeong, S.; Fischer, M. L.

    2015-12-01

    Methane is an important atmospheric pollutant that contributes to global warming and tropospheric ozone production. Methane mitigation could reduce near term climate change and improve air quality, but is hindered by a lack of knowledge of anthropogenic methane sources. Recent work has shown that methane emissions are not evenly distributed in space, or across emission sources, suggesting that a large fraction of anthropogenic methane comes from a few "super-emitters." We studied the distribution of super-emitters in California's southern San Joaquin Valley, where elevated levels of atmospheric CH4 have also been observed from space. Here, we define super-emitters as methane plumes that could be reliably detected (i.e., plume observed more than once in the same location) under varying wind conditions by airborne thermal infrared remote sensing. The detection limit for this technique was determined to be 4.5 kg CH4 h-1 by a controlled release experiment, corresponding to column methane enhancement at the point of emissions greater than 20% above local background levels. We surveyed a major oil production field, and an area with a high concentration of large dairies using a variety of airborne and ground-based measurements. Repeated airborne surveys (n=4) with the Hyperspectral Thermal Emission Spectrometer revealed 28 persistent methane plumes emanating from oil field infrastructure, including tanks, wells, and processing facilities. The likelihood that a given source type was a super-emitter varied from roughly 1/3 for processing facilities to 1/3000 for oil wells. 11 persistent plumes were detected in the dairy area, and all were associated with wet manure management. The majority (11/14) of manure lagoons in the study area were super-emitters. Comparing to a California methane emissions inventory for the surveyed areas, we estimate that super-emitters comprise a minimum of 9% of inventoried dairy emissions, and 13% of inventoried oil emissions in this region.

  5. Multi-component Lattice Boltzmann simulation of the hydrodynamics in drip emitters

    Directory of Open Access Journals (Sweden)

    Giacomo Falcucci

    2017-09-01

    Full Text Available In this paper, we propose a fast and efficient numerical technique based on the Lattice Boltzmann method (LBM to model the flow through a reference drip emitter geometry. The aim of the study is to demonstrate the applicability of the LBM as a reliable simulation tool for the hydraulic optimisation of irrigation systems. Results for the water flow through a rectangular drip emitter are in good agreement with literature numerical and experimental data. Furthermore, we demonstrate the feasibility of the proposed model to simulate a multi-component flow that could be used to simulate the presence of additives, contaminants, and suspended particles.

  6. Vertically aligned carbon nanotube emitter on metal foil for medical X-ray imaging.

    Science.gov (United States)

    Ryu, Je Hwang; Kim, Wan Sun; Lee, Seung Ho; Eom, Young Ju; Park, Hun Kuk; Park, Kyu Chang

    2013-10-01

    A simple method is proposed for growing vertically aligned carbon nanotubes on metal foil using the triode direct current plasma-enhanced chemical vapor deposition (PECVD). The carbon nanotube (CNT) electron emitter was fabricated using fewer process steps with an acid treated metal substrate. The CNT emitter was used for X-ray generation, and the X-ray image of mouse's joint was obtained with an anode current of 0.5 mA at an anode bias of 60 kV. The simple fabrication of a well-aligned CNT with a protection layer on metal foil, and its X-ray application, were studied.

  7. Computer simulation of the emittance growth due to noise in large hadron colliders

    International Nuclear Information System (INIS)

    Lebedev, V.

    1993-03-01

    The problem of emittance growth due to random fluctuations of the magnetic field in a hadron collider is considered. The results of computer simulations are compared with the analytical theory developed earlier. A good agreement was found between the analytical theory predictions and the computer simulations for the collider tunes located far enough from high order betatron resonances. The dependencies of the emittance growth rate on noise spectral density, beam separation at the Interaction Point (IP) and value of beam separation at long range collisions are studied. The results are applicable to the Superconducting Super Collider (SSC)

  8. Epigenetic Variation May Compensate for Decreased Genetic Variation with Introductions: A Case Study Using House Sparrows (Passer domesticus on Two Continents

    Directory of Open Access Journals (Sweden)

    Aaron W. Schrey

    2012-01-01

    Full Text Available Epigenetic mechanisms impact several phenotypic traits and may be important for ecology and evolution. The introduced house sparrow (Passer domesticus exhibits extensive phenotypic variation among and within populations. We screened methylation in populations from Kenya and Florida to determine if methylation varied among populations, varied with introduction history (Kenyan invasion <50 years old, Florida invasion ~150 years old, and could potentially compensate for decrease genetic variation with introductions. While recent literature has speculated on the importance of epigenetic effects for biological invasions, this is the first such study among wild vertebrates. Methylation was more frequent in Nairobi, and outlier loci suggest that populations may be differentiated. Methylation diversity was similar between populations, in spite of known lower genetic diversity in Nairobi, which suggests that epigenetic variation may compensate for decreased genetic diversity as a source of phenotypic variation during introduction. Our results suggest that methylation differences may be common among house sparrows, but research is needed to discern whether methylation impacts phenotypic variation.

  9. Risk Compensation Following Medical Male Circumcision: Results from a 1-Year Prospective Cohort Study of Young School-Going Men in KwaZulu-Natal, South Africa.

    Science.gov (United States)

    Govender, K; George, G; Beckett, S; Montague, C; Frohlich, J

    2018-02-01

    This study sought to assess risk compensation following voluntary medical male circumcision of young school-going men. Risk compensation is defined as an inadvertent increase in sexual risk behaviors and a corresponding decrease in self-perceived risk for contracting HIV following the application of a risk reduction technology. This study documented the sexual practices of circumcised (n = 485) and uncircumcised (n = 496) young men in 42 secondary schools at three time points (baseline and 6 and 12 months) in a sub-district of KwaZulu-Natal, South Africa. Study participants were aged from 16 to 24 years old. At the end of the study period, there was no significant difference between the two cohorts concerning learners' perceptions of being at risk of contracting HIV (interaction effect: b = -0.12, p = 0.40). There was also no significant difference in the number of sexual partners in the previous month (interaction effect: b = -0.23, p = 0.15). The proportion of learners who have never used a condom decreased significantly over time (time effect: b = -0.27, p = 0.01), and there was no difference between the circumcised and uncircumcised learners (interaction effect: b = -0.09, p = 0.91). Risk compensation, as evidenced in this study over a 1-year period, was not associated with undergoing voluntary medical male circumcision (VMMC) in our sample of young school-going men. However, it is of concern that at the end of this study, less than half of the sexually active sample in a high-HIV-prevalence community used condoms consistently in the previous month (39% for both study cohorts). The latter underscores the need to view VMMC as a potential entry point for planned HIV and sexuality education interventions targeting young men in this community.

  10. Enthalpy–entropy compensation

    Indian Academy of Sciences (India)

    Enthalpy–entropy compensation is the name given to the correlation sometimes observed between the estimates of the enthalpy and entropy of a reaction obtained from temperature-dependence data. Although the mainly artefactual nature of this correlation has been known for many years, the subject enjoys periodical ...

  11. Motion compensated digital tomosynthesis

    NARCIS (Netherlands)

    van der Reijden, Anneke; van Herk, Marcel; Sonke, Jan-Jakob

    2013-01-01

    Digital tomosynthesis (DTS) is a limited angle image reconstruction method for cone beam projections that offers patient surveillance capabilities during VMAT based SBRT delivery. Motion compensation (MC) has the potential to mitigate motion artifacts caused by respiratory motion, such as blur. The

  12. Teacher Compensation and Organization.

    Science.gov (United States)

    Kelley, Carolyn

    1997-01-01

    Examines changes in the conceptualization of schooling over time from an organizational perspective. Explores how compensation systems might be better designed to match alternative organizational designs, considering scientific management, effective schools, content-driven schooling, and high standards/high involvement schools as organizational…

  13. (statcom) in synchronous compensator

    African Journals Online (AJOL)

    eobe

    with fast response and low cost for stabilizing electricity grid power and voltage. ... The conventional and modified Newton-Raphson-based power flow equations .... The control of the reactive power exchange between .... because of its faster rate of convergence and accuracy ..... compensator, North American Power System.

  14. Reactive Power Compensating System.

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Timothy J.; El-Sharkawi, Mohamed A.; Venkata, Subrahmanyam S.

    1985-01-04

    The circuit was designed for the specific application of wind-driven induction generators. It has great potential for application in any situation where a varying reactive power load is present, such as with induction motors or generators, or for transmission network compensation.

  15. Improvement of electron emission characteristics of porous silicon emitter by using cathode reduction and electrochemical oxidation

    Energy Technology Data Exchange (ETDEWEB)

    Li, He; Wenjiang, Wang, E-mail: wwj@mail.xjtu.edu.cn; Xiaoning, Zhang

    2017-03-31

    Highlights: • An electron emitter based on porous silicon having the strong application potential was prepared in the studying. • A new simple and convenient post-treat technique was proposed to improve the electron emission properties of the PS emitter. • It demonstrated that the improving of the PS morphology and the oxygen distribution is very important to the PS emitter. - Abstract: A new simple and convenient post-treat technique combined the cathode reduction (CR) and electrochemical oxidation (ECO) was proposed to improve the electron emission properties of the surface-emitting cold cathodes based on the porous silicon (PS). It is demonstrated here that by introducing this new technique combined CR and ECO, the emission properties of the diode have been significantly improved than those as-prepared samples. The experimental results showed that the emission current densities and efficiencies of sample treated by CR were 62 μA/cm{sup 2} and 12.10‰, respectively, nearly 2 orders of magnitude higher than those of as-prepared sample. Furthermore, the CR-treated PS emitter shows higher repeatability and stability compared with the as-prepared PS emitter. The scanning electron microscope (SEM), atomic force microscope (AFM), energy dispersive spectrometer (EDS), furier transformed infrared (FTIR) spectroscopy results indicated that the improved mechanism is mainly due to the passivation of the PS, which not only improve the PS morphology by the passivation of the H{sup +} but also improve the uniformity of the oxygen content distribution in the whole PS layer. Therefore, the method combined the CR treatment and ECO is expected to be a valuable technique to enhance the electron emission characteristics of the PS emitter.

  16. Improvement of electron emission characteristics of porous silicon emitter by using cathode reduction and electrochemical oxidation

    International Nuclear Information System (INIS)

    Li, He; Wenjiang, Wang; Xiaoning, Zhang

    2017-01-01

    Highlights: • An electron emitter based on porous silicon having the strong application potential was prepared in the studying. • A new simple and convenient post-treat technique was proposed to improve the electron emission properties of the PS emitter. • It demonstrated that the improving of the PS morphology and the oxygen distribution is very important to the PS emitter. - Abstract: A new simple and convenient post-treat technique combined the cathode reduction (CR) and electrochemical oxidation (ECO) was proposed to improve the electron emission properties of the surface-emitting cold cathodes based on the porous silicon (PS). It is demonstrated here that by introducing this new technique combined CR and ECO, the emission properties of the diode have been significantly improved than those as-prepared samples. The experimental results showed that the emission current densities and efficiencies of sample treated by CR were 62 μA/cm"2 and 12.10‰, respectively, nearly 2 orders of magnitude higher than those of as-prepared sample. Furthermore, the CR-treated PS emitter shows higher repeatability and stability compared with the as-prepared PS emitter. The scanning electron microscope (SEM), atomic force microscope (AFM), energy dispersive spectrometer (EDS), furier transformed infrared (FTIR) spectroscopy results indicated that the improved mechanism is mainly due to the passivation of the PS, which not only improve the PS morphology by the passivation of the H"+ but also improve the uniformity of the oxygen content distribution in the whole PS layer. Therefore, the method combined the CR treatment and ECO is expected to be a valuable technique to enhance the electron emission characteristics of the PS emitter.

  17. Radiation doses and risks from internal emitters

    International Nuclear Information System (INIS)

    Harrison, John; Day, Philip

    2008-01-01

    This review updates material prepared for the UK Government Committee Examining Radiation Risks from Internal Emitters (CERRIE) and also refers to the new recommendations of the International Commission on Radiological Protection (ICRP) and other recent developments. Two conclusions from CERRIE were that ICRP should clarify and elaborate its advice on the use of its dose quantities, equivalent and effective dose, and that more attention should be paid to uncertainties in dose and risk estimates and their implications. The new ICRP recommendations provide explanations of the calculation and intended purpose of the protection quantities, but further advice on their use would be helpful. The new recommendations refer to the importance of understanding uncertainties in estimates of dose and risk, although methods for doing this are not suggested. Dose coefficients (Sv per Bq intake) for the inhalation or ingestion of radionuclides are published as reference values without uncertainty. The primary purpose of equivalent and effective dose is to enable the summation of doses from different radionuclides and from external sources for comparison with dose limits, constraints and reference levels that relate to stochastic risks of whole-body radiation exposure. Doses are calculated using defined biokinetic and dosimetric models, including reference anatomical data for the organs and tissues of the human body. Radiation weighting factors are used to adjust for the different effectiveness of different radiation types, per unit absorbed dose (Gy), in causing stochastic effects at low doses and dose rates. Tissue weighting factors are used to take account of the contribution of individual organs and tissues to overall detriment from cancer and hereditary effects, providing a simple set of rounded values chosen on the basis of age- and sex-averaged values of relative detriment. While the definition of absorbed dose has the scientific rigour required of a basic physical quantity

  18. A Follow-up Study on Return to Work in the Year After Reporting an Occupational Injury Stratified by Outcome of the Workers' Compensation System

    DEFF Research Database (Denmark)

    Rudbeck, Marianne; Johansen, Jens Peter; Omland, Øyvind

    2017-01-01

    benefits were granted by the municipalities independently of any compensation claim if sick-listed. RESULTS: Claimants with ongoing claims were the group with the largest proportion remaining on disability benefits. Claimants with rejected claims returned to work at the same rate (occupational disease......) or slower (industrial accident) compared to claimants with recognized claim without compensation the subsequent year and at a faster rate after decision. CONCLUSIONS: Compensation claims and proceedings of the workers' compensation system probably increase time to return to work, other factors as health...

  19. Altitude Compensating Nozzle

    Science.gov (United States)

    Ruf, Joseph H.; Jones, Daniel

    2015-01-01

    The dual-bell nozzle (fig. 1) is an altitude-compensating nozzle that has an inner contour consisting of two overlapped bells. At low altitudes, the dual-bell nozzle operates in mode 1, only utilizing the smaller, first bell of the nozzle. In mode 1, the nozzle flow separates from the wall at the inflection point between the two bell contours. As the vehicle reaches higher altitudes, the dual-bell nozzle flow transitions to mode 2, to flow full into the second, larger bell. This dual-mode operation allows near optimal expansion at two altitudes, enabling a higher mission average specific impulse (Isp) relative to that of a conventional, single-bell nozzle. Dual-bell nozzles have been studied analytically and subscale nozzle tests have been completed.1 This higher mission averaged Isp can provide up to a 5% increase2 in payload to orbit for existing launch vehicles. The next important step for the dual-bell nozzle is to confirm its potential in a relevant flight environment. Toward this end, NASA Marshall Space Flight Center (MSFC) and Armstrong Flight Research Center (AFRC) have been working to develop a subscale, hot-fire, dual-bell nozzle test article for flight testing on AFRC's F15-D flight test bed (figs. 2 and 3). Flight test data demonstrating a dual-bell ability to control the mode transition and result in a sufficient increase in a rocket's mission averaged Isp should help convince the launch service providers that the dual-bell nozzle would provide a return on the required investment to bring a dual-bell into flight operation. The Game Changing Department provided 0.2 FTE to ER42 for this effort in 2014.

  20. Movement of Irrigation Water in Soil from a Surface Emitter

    Directory of Open Access Journals (Sweden)

    Ibrahim Abbas Dawood

    2016-09-01

    Full Text Available rickle irrigation is one of the most conservative irrigation techniques since it implies supplying water directly on the soil through emitters. Emitters dissipate energy of water at the end of the trickle irrigation system and provide water at emission points. The area wetted by an emitter depends upon the discharge of emitter, soil texture, initial soil water content, and soil permeability. The objectives of this research were to predict water distribution profiles through different soils for different conditions and quantify the distribution profiles in terms of main characteristics of soil and emitter. The wetting patterns were simulated at the end of each hour for a total time of application of 12 hrs, emitter discharges of 0.5, 0.75, 1, 2, 3, 4, and 5 lph, and five initial volumetric soil water contents. Simulation of water flow from a single surface emitter was carried out by using the numerically-based software Hydrus-2D/3D, Version 2.04. Two approaches were used in developing formulas to predict the domains of the wetted pattern. In order to verify the results obtained by implementing the software Hydrus-2D/3D a field experiment was conducted to measure the wetted diameter and compare measured values with simulated ones. The results of the research showed that the developed formulas to express the wetted diameter and depth in terms of emitter discharge, time of application, and initial soil water content are very general and can be used with very good accuracy.

  1. Coupling of Quantum Emitters in Nanodiamonds to Plasmonic Structures

    DEFF Research Database (Denmark)

    Kumar, Shailesh

    This PhD thesis describes work towards the enhancement and efficient channeling of photons emitted from a single photon emitter. The emitter used is a defect center, the Nitrogen-Vacancy (NV) center, in diamond. The NV-center has many unique properties, such as long coherence time of its electron...

  2. Emittance growth due to negative-mass instability above transition

    International Nuclear Information System (INIS)

    Ng, King-Yuen.

    1994-08-01

    Due to space-charge effect, there is a growth of bunch emittance across transition as a result of negative-mass instability. The models of growth at cutoff frequency and growth from high-frequency Schottky noise are reviewed. The difficulties of performing reliable simulations are discussed. An intuitive self-bunching model for estimating emittance growth is presented

  3. Emittance formula for slits and pepper-pot measurement

    International Nuclear Information System (INIS)

    Zhang, M.

    1996-10-01

    In this note, a rigid formula for slits and pepper-pot emittance measurement is derived. The derivation is based on the one- dimensional slit measurement setup. A mathematical generalization of the slit emittance formula to the pepper-pot measurement is discussed

  4. MEV Energy Electrostatic Accelerator Ion Beam Emittance Measurement

    OpenAIRE

    I.G. Ignat’ev; M.I. Zakharets; S.V. Kolinko; D.P. Shulha

    2014-01-01

    The testing equipment was designed, manufactured and tried out permitting measurements of total current, current profile and emittance of an ion beam extracted from the ion beam. MeV energy electrostatic accelerator ion H + beam emittance measurement results are presented.

  5. Measurement of the transverse emittance for the NSC Pelletron

    International Nuclear Information System (INIS)

    Rodriques, G.; Mandal, A.; Chopra, S.; Joshi, R.; Datta, S.K.; Roy, A.

    1998-01-01

    The knowledge of the emittance (transverse and longitudinal) of the NSC pelletron is essential for matching the acceptance of the LINAC which is to be installed to augment the pelletron beam energies. The transverse emittance of NSC pelletron has been measured by employing a focussing element and a down-stream beam profile monitor

  6. Jamming of Quantum Emitters by Active Coated Nanoparticles

    DEFF Research Database (Denmark)

    Arslanagic, Samel; Ziolkowski, Richard W.

    2013-01-01

    to effectively cloak the emitters to a far-field observer is reported and explained through thorough near- and far-field investigations. This property offers an interesting route toward the jamming of quantum emitters/nanoantennas that might be of potential use, for instance, in biological fluorescence assays...

  7. Low emittance lattices for electron storage rings revisited

    International Nuclear Information System (INIS)

    Trbojevic, D.; Courant, E.

    1994-01-01

    Conditions for the lowest possible emittance of the lattice for electron storage rings are obtained by a simplified analytical approach. Examples of electron storage lattices with minimum emittances are presented. A simple graphical presentation in the normalized dispersion space (Floquet's transformation) is used to illustrate the conditions and results

  8. Stock Option Compensation and Managerial Turnover

    OpenAIRE

    Raluca Georgiana NASTASESCU

    2009-01-01

    This study examines the association between managerial turnover and equity-based compensation. I investigate whether stock options act to bond executives to their firms and whether retention of managers is a motivation of companies in designing CEO incentive contracts. The results show that stock options do negatively influence the probability of a CEO leaving the company. The monetary cost of losing the value of equity-based compensation package keeps the manager with his company. I also fin...

  9. Evaluations of carbon nanotube field emitters for electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Nakahara, Hitoshi, E-mail: nakahara@nagoya-u.jp [Department of Quantum Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Kusano, Yoshikazu; Kono, Takumi; Saito, Yahachi [Department of Quantum Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan)

    2009-11-30

    Brightness of carbon nanotube (CNT) emitters was already reported elsewhere. However, brightness of electron emitter is affected by a virtual source size of the emitter, which strongly depends on electron optical configuration around the emitter. In this work, I-V characteristics and brightness of a CNT emitter are measured under a practical field emission electron gun (e-gun) configuration to investigate availability of CNT for electron microscopy. As a result, it is obtained that an emission area of MWNT is smaller than its tip surface area, and the emission area corresponds to a five-membered-ring with 2nd nearest six-membered-rings on the MWNT cap surface. Reduced brightness of MWNT is measured as at least 2.6x10{sup 9} A/m{sup 2} sr V. It is concluded that even a thick MWNT has enough brightness under a practical e-gun electrode configuration and suitable for electron microscopy.

  10. Evaluations of carbon nanotube field emitters for electron microscopy

    Science.gov (United States)

    Nakahara, Hitoshi; Kusano, Yoshikazu; Kono, Takumi; Saito, Yahachi

    2009-11-01

    Brightness of carbon nanotube (CNT) emitters was already reported elsewhere. However, brightness of electron emitter is affected by a virtual source size of the emitter, which strongly depends on electron optical configuration around the emitter. In this work, I- V characteristics and brightness of a CNT emitter are measured under a practical field emission electron gun (e-gun) configuration to investigate availability of CNT for electron microscopy. As a result, it is obtained that an emission area of MWNT is smaller than its tip surface area, and the emission area corresponds to a five-membered-ring with 2nd nearest six-membered-rings on the MWNT cap surface. Reduced brightness of MWNT is measured as at least 2.6×109 A/m 2 sr V. It is concluded that even a thick MWNT has enough brightness under a practical e-gun electrode configuration and suitable for electron microscopy.

  11. Internal Auger emitters: effects on spermatogenesis and oogenesis in mice

    International Nuclear Information System (INIS)

    Rao, D.V.; Mylavarapu, V.B.; Sastry, K.S.R.; Howell, R.W.

    1988-01-01

    The in vivo biological effects of Auger emitters are investigated using [A] spermatogenesis in mouse testis, and [B] oogenesis in mouse ovary as experimental models. Spermhead survival and induction of abnormal sperm, following intratesticular administration of radiopharmaceuticals, were the end points in Model A. Of interest in Model B is primary oocyte survival after intraperitoneal injection of the radiochemicals. The effectiveness of the Auger emitter is determined relative to its beta emitting companion or external X-rays in the absence of such an analogue. Results reveal pronounced effects of Auger emitters on all end points, not dependent on mode of administration. The efficacy of the Auger emitter is related intimately to its subcellular distribution, which, is governed by the chemical form of the carrier molecule. Conventional dosimetry is inadequate and biophysically meaningful dosimetric approaches are needed to understand in vivo effects of Auger emitters. (author)

  12. Executive compensation and firm performance: Evidence from Indian firms

    Directory of Open Access Journals (Sweden)

    Mehul Raithatha

    2016-09-01

    Full Text Available The study examines the relationship between executive compensation and firm performance among Indian firms. The evidence suggests that firm performance measured by accounting, as well as market-based measures, significantly affects executive compensation. We also test for the presence of persistence in executive compensation by employing the system-generalised methods of moments (GMM estimator. We find significant persistence in executive compensation among the sample firms. Further, we report the absence of pay–performance relationship among the smaller sample firms and business group affiliated firms. Thus, our findings cast doubts over the performance-based executive compensation practices of Indian business group affiliated firms.

  13. Plasma treatment for producing electron emitters

    Science.gov (United States)

    Coates, Don Mayo; Walter, Kevin Carl

    2001-01-01

    Plasma treatment for producing carbonaceous field emission electron emitters is disclosed. A plasma of ions is generated in a closed chamber and used to surround the exposed surface of a carbonaceous material. A voltage is applied to an electrode that is in contact with the carbonaceous material. This voltage has a negative potential relative to a second electrode in the chamber and serves to accelerate the ions toward the carbonaceous material and provide an ion energy sufficient to etch the exposed surface of the carbonaceous material but not sufficient to result in the implantation of the ions within the carbonaceous material. Preferably, the ions used are those of an inert gas or an inert gas with a small amount of added nitrogen.

  14. International Standardization of Pure Beta Emitters

    International Nuclear Information System (INIS)

    Los Arcos, Jose Maria; Rodriguez, Leonor

    2006-01-01

    The paper describes the traditional methods of standardization of Pure Beta Emitters, their principal characteristics, advantage and drawbacks. It does comparisons between two metrological LSC methods: Triple to double coincidence ratio (TDCR) method and the CIEMAT/NIST method and presents the result obtained with several Key Comparisons serving as practical test of both methods. Both of them represent the siferrit of methods of standardization of pure (and mixed decay) radionuclides. ESIR WG of CCRI(II) is to implement a reference exchange system for the permanent equivalence of β, α and electron capture nuclides, similar to traditional SIR gamma. ESIR project is currently testing a new XAN scintillator and operational tests of the whole system at BIPM are expected by the end of 2006 (test restricted to ESIR NMI members)

  15. Beta-delayed proton emitter $^{113}Xe$

    CERN Document Server

    Hagberg, E; Jonson, B; Jørgensen, B; Kugler, E; Mowinckel, T

    1973-01-01

    The ISOLDE facility at the CERN synchrocyclotron has been used for extending the series of beta -delayed proton emitters in xenon to masses lighter than those previously observed (/sup 115,117/Xe). Owing to the rapid decrease of the yields, experiments with solid-state counters were inconclusive, and instead a new and much more sensitive method based on nuclear emulsions was developed. The mass range 111-114 showed one new activity, /sup 113/Xe, with a half-life of 2.8+or-0.2 sec. From measurements of the track lengths for a total of 1130 protons from /sup 113/Xe it was possible to determine the energy spectrum. The results extend the systematics of beta -strength functions in the light xenon isotopes. (19 refs).

  16. Passivated emitters in silicon solar cells

    International Nuclear Information System (INIS)

    King, R.R.; Gruenbaum, P.E.; Sinton, R.A.; Swanson, R.M.

    1990-01-01

    In high-efficiency silicon solar cells with low metal contact coverage fractions and high bulk lifetimes, cell performance is often dominated by recombination in the oxide-passivated diffusions on the cell surface. Measurements of the emitter saturation current density, J o , of oxide-passivated, boron and phosphorus diffusions are presented, and from these measurements, the dependence of surface recombination velocity on dopant concentration was extracted. The lowest observed values of J o which are stable under UV light are given for both boron- and phosphorus-doped, oxide-passivated diffusions, for both textured and untextured surfaces. Contour plots which incorporate the above data have been applied to two types of backside-contact solar cells with large area (37.5 cm 2 ) and one-sun efficiencies up to 22.7%

  17. Theory and measurements of emittance preservation in plasma wakefield acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Frederico, Joel

    2016-12-01

    In this dissertation, we examine the preservation and measurement of emittance in the plasma wakefield acceleration blowout regime. Plasma wakefield acceleration (PWFA) is a revolutionary approach to accelerating charged particles that has been demonstrated to have the potential for gradients orders of magnitude greater than traditional approaches. The application of PWFA to the design of a linear collider will make new high energy physics research possible, but the design parameters must first be shown to be competitive with traditional methods. Emittance preservation is necessary in the design of a linear collider in order to maximize luminosity. We examine the conditions necessary for circular symmetry in the PWFA blowout regime, and demonstrate that current proposals meet these bounds. We also present an application of beam lamentation which describes the process of beam parameter and emittance matching. We show that the emittance growth saturates as a consequence of energy spread in the beam. The initial beam parameters determine the amount of emittance growth, while the contribution of energy spread is negligible. We also present a model for ion motion in the presence of a beam that is much more dense than the plasma. By combining the model of ion motion and emittance growth, we find the emittance growth due to ion motion is minimal in the case of marginal ion motion. In addition, we present a simulation that validates the ion motion model, which is under further development to examine emittance growth of both marginal and pronounced ion motion. Finally, we present a proof-of-concept of an emittance measurement which may enable the analysis of emittance preservation in future PWFA experiments.

  18. Non-exponential spontaneous emission dynamics for emitters in a time-dependent optical cavity

    NARCIS (Netherlands)

    Thyrrestrup Nielsen, Henri; Hartsuiker, A.; Gerard, J.M.; Vos, Willem L.

    2013-01-01

    We have theoretically studied the effect of deterministic temporal control of spontaneous emission in a dynamic optical microcavity. We propose a new paradigm in light emission: we envision an ensemble of two-level emitters in an environment where the local density of optical states is modified on a

  19. Multichannel all–optical switch based on a thin slab of resonant two–level emitters

    Directory of Open Access Journals (Sweden)

    Malikov Ramil

    2017-01-01

    Full Text Available We discuss the possibility of using a thin layer of inhomogeneously broadened resonant emitters as a multichannel all–optical switch. Switching time from the lower stable branch of the system's bistable characteristics to the upper one and vice versa, which determines the speed of operation of a bistable device, is studied.

  20. Addressing inadequate compensation | IDRC - International ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2016-08-12

    Aug 12, 2016 ... The issue LSLAs raise a number of concerns regarding compensation, including ... at a meeting with traders in Lamu, Kenya, where a new port is planned. ... compensation and a fair share of benefits and risks in land deals.

  1. Structuring competitive physician compensation models.

    Science.gov (United States)

    Mobley, Kim; Turcotte, Claire

    2010-12-01

    When developing and reviewing their physician compensation programs, healthcare organizations should: Understand the market data. Test outcomes of incentive plans for fair market value. Check total compensation for fair market value and reasonableness.

  2. Compensation methods to support generic graph editing: A case study in automated verification of schema requirements for an advanced transaction model

    NARCIS (Netherlands)

    Even, S.J.; Spelt, D.

    Compensation plays an important role in advanced transaction models, cooperative work, and workflow systems. However, compensation operations are often simply written as a^−1 in transaction model literature. This notation ignores any operation parameters, results, and side effects. A schema designer

  3. Comparison between arc drops in ignited thermionic converters with and without ion reflections at the emitter

    International Nuclear Information System (INIS)

    Lundgren, L.

    1985-01-01

    The output performance of two thermionic energy converters is compared. One converter has a normal emitter, working with zero field at the emitter which is close to the optimum working point, and the other has a low work function emitter and ion reflection at the emitter. A simple model of the plasma and the sheaths shows that a converter working with a low work function emitter and ion reflections gives a worse performance than a similar converter with a normal emitter

  4. RELIABILITY OF LENTICULAR EXPANSION COMPENSATORS

    Directory of Open Access Journals (Sweden)

    Gabriel BURLACU,

    2011-11-01

    Full Text Available Axial lenticular compensators are made to take over the longitudinal heat expansion, shock , vibration and noise, made elastic connections for piping systems. In order to have a long life for installations it is necessary that all elements, including lenticular compensators, have a good reliability. This desire can be did by technology of manufactoring and assembly of compensators, the material for lenses and by maintenance.of compensator

  5. Decreasing the emittance using a multi-period Robinson wigglers in TPS

    Energy Technology Data Exchange (ETDEWEB)

    Huamg, C. W., E-mail: huang.zw@nsrrc.org.tw [Department of Physics, National Tsing Hua University Hsinchu 30043, Taiwan (China); Hwang, C. S., E-mail: cshwang@nsrrc.org.tw [NSRRC, 101 Hsin-Ann Road, Hsinchu Science Park, Hsinchu 30076, Taiwan (China); Department of Electrophysics, National Chiao Tung University, Hsinchu 300, Taiwan (China); Lee, S. Y., E-mail: shylee@indiana.edu [Department of Physics, Indiana University (United States)

    2016-07-27

    The Taiwan Photon Source (TPS) has been successfully commissioned. However, the minimum emittance in the TPS lattice is 1.6 nm rad. In the existing TPS storage ring lattice, it is imperative to reduce the emittance to below 1 nm rad. Therefore, a feasibility study for reducing the effective emittance of the TPS storage ring by using a Robinson wiggler was launched; the reduction is necessary to enhance the photon brilliance. In this study, a permanent-magnet multiperiod Robinson wiggler (MRW) was developed for use instead of the single-period Robinson wiggler. In general, the quadruple field of a combined function magnet in the storage ring is approximately few tesla per meter. According to beam dynamic analysis, we found that it is necessary to adopt a high gradient (40 T/m) combined-function MRW magnet to reduce the emittance effectively. Therefore, a high gradient field strength is required in the combined function MRW magnet. In this study, the quadrupole field strength of the MRW magnet was allowed to be approximately 40 T/m at a magnet gap of 20 mm. The period length of the MRW magnet was 300 mm and the period number was 16. The of MRWs is discussed in regard to the possibility of increasing the photon brilliance from IU22.

  6. Effectiveness of employer financial incentives in reducing time to report worker injury: an interrupted time series study of two Australian workers' compensation jurisdictions.

    Science.gov (United States)

    Lane, Tyler J; Gray, Shannon; Hassani-Mahmooei, Behrooz; Collie, Alex

    2018-01-05

    Early intervention following occupational injury can improve health outcomes and reduce the duration and cost of workers' compensation claims. Financial early reporting incentives (ERIs) for employers may shorten the time between injury and access to compensation benefits and services. We examined ERI effect on time spent in the claim lodgement process in two Australian states: South Australia (SA), which introduced them in January 2009, and Tasmania (TAS), which introduced them in July 2010. Using administrative records of 1.47 million claims lodged between July 2006 and June 2012, we conducted an interrupted time series study of ERI impact on monthly median days in the claim lodgement process. Time periods included claim reporting, insurer decision, and total time. The 18-month gap in implementation between the states allowed for a multiple baseline design. In SA, we analysed periods within claim reporting: worker and employer reporting times (similar data were not available in TAS). To account for external threats to validity, we examined impact in reference to a comparator of other Australian workers' compensation jurisdictions. Total time in the process did not immediately change, though trend significantly decreased in both jurisdictions (SA: -0.36 days per month, 95% CI -0.63 to -0.09; TAS: 0.35, -0.50 to -0.20). Claim reporting time also decreased in both (SA: -1.6 days, -2.4 to -0.8; TAS: -5.4, -7.4 to -3.3). In TAS, there was a significant increase in insurer decision time (4.6, 3.9 to 5.4) and a similar but non-significant pattern in SA. In SA, worker reporting time significantly decreased (-4.7, -5.8 to -3.5), but employer reporting time did not (-0.3, -0.8 to 0.2). The results suggest that ERIs reduced claim lodgement time and, in the long-term, reduced total time in the claim lodgement process. However, only worker reporting time significantly decreased in SA, indicating that ERIs may not have shortened the process through the intended target of

  7. Tunable, Room Temperature THZ Emitters Based on Nonlinear Photonics

    Science.gov (United States)

    Sinha, Raju

    The Terahertz (1012 Hz) region of the electromagnetic spectrum covers the frequency range from roughly 300 GHz to 10 THz, which is in between the microwave and infrared regimes. The increasing interest in the development of ultra-compact, tunable room temperature Terahertz (THz) emitters with wide-range tunability has stimulated in-depth studies of different mechanisms of THz generation in the past decade due to its various potential applications such as biomedical diagnosis, security screening, chemical identification, life sciences and very high speed wireless communication. Despite the tremendous research and development efforts, all the available state-of-the-art THz emitters suffer from either being large, complex and costly, or operating at low temperatures, lacking tunability, having a very short spectral range and a low output power. Hence, the major objective of this research was to develop simple, inexpensive, compact, room temperature THz sources with wide-range tunability. We investigated THz radiation in a hybrid optical and THz micro-ring resonators system. For the first time, we were able to satisfy the DFG phase matching condition for the above-mentioned THz range in one single device geometry by employing a modal phase matching technique and using two separately designed resonators capable of oscillating at input optical waves and generated THz waves. In chapter 6, we proposed a novel plasmonic antenna geometry – the dimer rod-tapered antenna (DRTA), where we created a hot-spot in the nanogap between the dimer arms with a very large intensity enhancement of 4.1x105 at optical resonant wavelength. Then, we investigated DFG operation in the antenna geometry by incorporating a nonlinear nanodot in the hot-spot of the antenna and achieved continuously tunable enhanced THz radiation across 0.5-10 THz range. In chapter 8, we designed a multi-metallic resonators providing an ultrasharp toroidal response at THz frequency, then fabricated and

  8. Working and Living in Northern vs Southern Ontario Is Associated with the Duration of Compensated Time off Work: A Retrospective Cohort Study

    Directory of Open Access Journals (Sweden)

    S Senthanar

    2015-07-01

    Full Text Available Background: Northern Ontario, Canada has a larger elder population, more resource-based employment, and limited access to physicians and specialists compared to southern Ontario. Given these important differences, it is possible that work disability rates will vary between the two Ontario jurisdictions. Objective: To determine the association between time lost due to workplace injuries and illnesses occurring in northern vs southern Ontario and work disability duration from 2006– 2011. Methods: The study base included all lost-time claims approved by the Workplace Safety and Insurance Board in Ontario, Canada for workplace injury or illness compensation occurring between January 1, 2006 and December 31, 2011. All eligible participants had to be 18 years of age or older at the time of making the claim and participants were excluded if one of the three variables used to determine location (claimant home postal code, workplace geographical code, and WSIB firm location were missing. Multivariable proportional hazards regression models were used to estimate hazard ratios and 95% confidence intervals adjusted for sex, age, occupation, part of body, and nature of injury relating Ontario geographical location to compensated time off work. Results: A total of 156 453 lost-time claims were approved over the study period. Injured and ill workers from northern Ontario were 16% less likely to return to work than those from southern Ontario. Adjustment for potential confounding factors had no effect. Conclusion: The disability duration in northern Ontario is longer than that in southern Ontario. Future research should focus on assessing the relevant factors associated with this observation to identify opportunities for intervention.

  9. Compensability index for compensation radiotherapy after treatment interruptions

    International Nuclear Information System (INIS)

    Putora, Paul Martin; Schmuecking, Michael; Aebersold, Daniel; Plasswilm, Ludwig

    2012-01-01

    The goal of our work was to develop a simple method to evaluate a compensation treatment after unplanned treatment interruptions with respect to their tumour- and normal tissue effect. We developed a software tool in java programming language based on existing recommendations to compensate for treatment interruptions. In order to express and visualize the deviations from the originally planned tumour and normal tissue effects we defined the compensability index. The compensability index represents an evaluation of the suitability of compensatory radiotherapy in a single number based on the number of days used for compensation and the preference of preserving the originally planned tumour effect or not exceeding the originally planned normal tissue effect. An automated tool provides a method for quick evaluation of compensation treatments. The compensability index calculation may serve as a decision support system based on existing and established recommendations

  10. Compensability index for compensation radiotherapy after treatment interruptions

    Directory of Open Access Journals (Sweden)

    Putora Paul

    2012-12-01

    Full Text Available Abstract Background The goal of our work was to develop a simple method to evaluate a compensation treatment after unplanned treatment interruptions with respect to their tumour- and normal tissue effect. Methods We developed a software tool in java programming language based on existing recommendations to compensate for treatment interruptions. In order to express and visualize the deviations from the originally planned tumour and normal tissue effects we defined the compensability index. Results The compensability index represents an evaluation of the suitability of compensatory radiotherapy in a single number based on the number of days used for compensation and the preference of preserving the originally planned tumour effect or not exceeding the originally planned normal tissue effect. An automated tool provides a method for quick evaluation of compensation treatments. Conclusions The compensability index calculation may serve as a decision support system based on existing and established recommendations.

  11. Emittance and beam size distortion due to linear coupling

    International Nuclear Information System (INIS)

    Parzen, G.

    1993-01-01

    At injection, the presence of linear coupling may result in an increased beam emittance and in increased beam dimensions. Results for the emittance in the presence of linear coupling will be found. These results for the emittance distortion show that the harmonics of the skew quadrupole field close to ν x + ν y are the important harmonics. Results will be found for the important driving terms for the emittance distortion. It will be shown that if these driving terms are corrected, then the total emittance is unchanged, var-epsilon x + var-epsilon y = var-epsilon 1 + var-epsilon 2 . Also, the increase in the beam dimensions will be limited to a factor which is less than 1.414. If the correction is good enough, see below for details, one can achieve var-epsilon 1 = var-epsilon x , var-epsilon 2 = var-epsilon where var-epsilon 1 , var-epsilon 2 are the emittances in the presence of coupling, and the beam dimensions are unchanged. Global correction of the emittance and beam size distortion appears possible

  12. Design and Development of Emittance Measurement Device by Using the Pepper-pot Technique

    Science.gov (United States)

    Pakluea, S.; Rimjaem, S.

    2017-09-01

    Transverse emittance of a charged particle beam is one of the most important properties that reveals the quality of the beam. It is related to charge density, transvers size and angular displacement of the beam in transverse phase space. There are several techniques to measure the transverse emittance value. One of practical methods is the pepper-pot technique, which can measure both horizontal and vertical emittance value in a single measurement. This research concentrates on development of a pepper-pot device to measure the transverse emittance of electron beam produced from an accelerator injector system, which consists of a thermionic cathode RF electron gun and an alpha magnet, at the Plasma and Beam Physics Research Facility, Chiang Mai University. Simulation of beam dynamics was conducted with programs PARMELA, ELEGANT and self-developed codes using C and MATLAB. The geometry, dimensions and location of the pepper-pot as well as its corresponding screen station position were included in the simulation. The result from this study will be used to design and develop a practical pepper-pot experimental station.

  13. An asymmetric emittance electron source for the GALAXIE dielectric-laser accelerator injector

    Energy Technology Data Exchange (ETDEWEB)

    Valloni, A.; Cahill, A.; Fukusawa, A.; Musumeci, P.; Spataro, B.; Yakub, A.; Rosenzweig, J. B. [Dept. of Physics and Astronomy, University of California, Los Angeles, 405 Hilgard Ave., Los Angeles, CA 90034 (United States); Accelerator Division, Laboratori Nazionali di Frascati (INFN-LNF), Via E. Fermi 40, Frascati (RM) 00044 (Italy); Dept. of Physics and Astronomy, University of California, Los Angeles, 405 Hilgard Ave., Los Angeles, CA 90034 (United States)

    2012-12-21

    The GALAXIE project is a program to develop an all-optical, very high field accelerator and undulator integrated SASE FEL system based on dielectric laser-excited structures that support >GV/m fields. These structures are very wide in one direction to allow adequate charge given beam loading considerations, but also having small (subwavelength) apertures in the narrow direction. Such small vertical dimensions yield strict restrictions on the emittance in this direction, while no such constraint exists in the wide transverse direction. However, the overall beam brightness is restricted by the performance requirements on the FEL. To meet these demands, we are studying a very high field gun with a magnetized cathode, yielding a beam with angular momentum content. This beam is then subject to a skew-quad triplet that splits the emittances; this process is reversed to give a round beam after acceleration. This symmetric emittance beam avoids gain-degrading multiple-transverse-mode operation of the FEL, which also demands that the effects of the angular momentum in the beam be mitigated. In this paper we discuss the RF design of an X-band gun to be operated at {approx}200 MV/m peak field giving a 1 pC magnetized beam with unprecedented brightness. We examine the design of the focusing and skew-quad systems, investigating the associated beam dynamics and efficacy of emittance splitting.

  14. High resolution structuring of emitter tips for the gaseous field ionization source

    International Nuclear Information System (INIS)

    Kubby, J.A.; Siegel, B.M.

    1986-01-01

    Extraction of a stable, high brightness ion beam from an apertured field ion emitter surface requires microfabrication procedures to sculpture the surface topography on both microscopic (100 --1000 nm) and near atomic (10 --100 nm) length scales. Structuring on a near atomic scale is required to confine and stabilize the ion beam by local enhancement of the surface electrostatic field and to orient that emission on the optical axis. Control of the emitter contour on a microscopic scale is required for manipulating the supply of neutral molecules to the ionization site and also affects beam stability. We have developed a method using ion milling for configuring surface contour on microscopic and near atomic length scales which utilizes the morphological changes occurring at ion bombarded surfaces as a result of erosion by sputtering. A SEM study of the microscopic emitter topographical development is compared to computer simulations of the kinematical wave equation which depicts the erosion process. In this way, prediction of configuration on a length scale large compared to the ion penetration depth has been established. TEM observations show the surface development on the length scale of ion penetration depth. Preliminary results using this microfabricated emitter in a gaseous field ion source to produce a hydrogen ion beam with high angular beam confinement are given. Requirements for surface topography that are essential to obtain stable high brightness ion beams are discussed

  15. Coherent single-photon absorption by single emitters coupled to one-dimensional nanophotonic waveguides

    Energy Technology Data Exchange (ETDEWEB)

    Chen Yuntian; Wubs, Martijn; Moerk, Jesper [DTU Fotonik, Department of Photonics Engineering, Oersteds Plads, DK-2800 Kgs Lyngby (Denmark); Koenderink, A Femius, E-mail: yche@fotonik.dtu.dk [Center for Nanophotonics, FOM Institute for Atomic and Molecular Physics (AMOLF), Science Park 104, 1098 XG Amsterdam (Netherlands)

    2011-10-15

    We study the dynamics of single-photon absorption by a single emitter coupled to a one-dimensional waveguide that simultaneously provides channels for spontaneous emission (SE) decay and a channel for the input photon. We have developed a time-dependent theory that allows us to specify any input single-photon wavepacket guided by the waveguide as the initial condition, and calculate the excitation probability of the emitter, as well as the time evolution of the transmitted and reflected fields. For single-photon wavepackets with a Gaussian spectrum and temporal shape, we obtain analytical solutions for the dynamics of absorption, with maximum atomic excitation {approx}40%. We furthermore propose a terminated waveguide to aid the single-photon absorption. We found that for an emitter placed at an optimal distance from the termination, the maximum atomic excitation due to an incident single-photon wavepacket can exceed 70%. This high value is a direct consequence of the high SE {beta}-factor for emission into the waveguide. Finally, we have also explored whether waveguide dispersion could aid single-photon absorption by pulse shaping. For a Gaussian input wavepacket, we found that the absorption efficiency can be improved by a further 4% by engineering the dispersion. Efficient single-photon absorption by a single emitter has potential applications in quantum communication and quantum computation. (paper)

  16. Design of a minimum emittance nBA lattice

    Science.gov (United States)

    Lee, S. Y.

    1998-04-01

    An attempt to design a minimum emittance n-bend achromat (nBA) lattice has been made. One distinct feature is that dipoles with two different lengths were used. As a multiple bend achromat, five bend achromat lattices with six superperiod were designed. The obtained emittace is three times larger than the theoretical minimum. Tunes were chosen to avoid third order resonances. In order to correct first and second order chromaticities, eight family sextupoles were placed. The obtained emittance of five bend achromat lattices is almost equal to the minimum emittance of five bend achromat lattice consisting of dipoles with equal length.

  17. Remote detection of single emitters via optical waveguides

    Science.gov (United States)

    Then, Patrick; Razinskas, Gary; Feichtner, Thorsten; Haas, Philippe; Wild, Andreas; Bellini, Nicola; Osellame, Roberto; Cerullo, Giulio; Hecht, Bert

    2014-05-01

    The integration of lab-on-a-chip technologies with single-molecule detection techniques may enable new applications in analytical chemistry, biotechnology, and medicine. We describe a method based on the reciprocity theorem of electromagnetic theory to determine and optimize the detection efficiency of photons emitted by single quantum emitters through truncated dielectric waveguides of arbitrary shape positioned in their proximity. We demonstrate experimentally that detection of single quantum emitters via such waveguides is possible, confirming the predicted behavior of the detection efficiency. Our findings blaze the trail towards efficient lensless single-emitter detection compatible with large-scale optofluidic integration.

  18. Multi-dimensional beam emittance and β-functions

    International Nuclear Information System (INIS)

    Buon, J.

    1993-05-01

    The concept of r.m.s. emittance is extended to the case of several degrees of freedom that are coupled. That multi-dimensional emittance is lower than the product of the emittances attached to each degree of freedom, but is conserved in a linear motion. An envelope-hyperellipsoid is introduced to define the β-functions of the beam envelope. On the contrary of an one-degree of freedom motion, it is emphasized that these envelope functions differ from the amplitude functions of the normal modes of motion as a result of the difference between the Liouville and Lagrange invariants. (author) 4 refs

  19. Engineered Emitters for Improved Silicon Photovoltaics

    Science.gov (United States)

    Kamat, Ronak A.

    In 2014, installation of 5.3GW of new Photovoltaic (PV) systems occurred in the United States, raising the total installed capacity to 16.36GW. Strong growth is predicted for the domestic PV market with analysts reporting goals of 696GW by 2020. Conventional single crystalline silicon cells are the technology of choice, accounting for 90% of the installations in the global commercial market. Cells made of GaAs offer higher efficiencies, but at a substantially higher cost. Thin film technologies such as CIGS and CdTe compete favorably with multi-crystalline Si (u-Si), but at 20% efficiency, still lag the c-Si cell in performance. The c-Si cell can be fabricated to operate at approximately 25% efficiency, but commercially the efficiencies are in the 18-21% range, which is a direct result of cost trade-offs between process complexity and rapid throughput. With the current cost of c-Si cell modules at nearly 0.60/W. The technology is well below the historic metric of 1/W for economic viability. The result is that more complex processes, once cost-prohibitive, may now be viable. An example is Panasonic's HIT cell which operates in the 22-24% efficiency range. To facilitate research and development of novel PV materials and techniques, RIT has developed a basic solar cell fabrication process. Student projects prior to this work had produced cells with 12.8% efficiency using p type substrates. This thesis reports on recent work to improve cell efficiencies while simultaneously expanding the capability of the rapid prototyping process. In addition to the p-Si substrates, cells have been produced using n-Si substrates. The cell emitter, which is often done with a single diffusion or implant has been re-engineered using a dual implant of the same dose. This dual-implanted emitter has been shown to lower contact resistance, increase Voc, and increase the efficiency. A p-Si substrate cell has been fabricated with an efficiency of 14.6% and n-Si substrate cell with a 13

  20. Improved Rare-Earth Emitter Hollow Cathode

    Science.gov (United States)

    Goebel, Dan M.

    2011-01-01

    An improvement has been made to the design of the hollow cathode geometry that was created for the rare-earth electron emitter described in Compact Rare Earth Emitter Hollow Cathode (NPO-44923), NASA Tech Briefs, Vol. 34, No. 3 (March 2010), p. 52. The original interior assembly was made entirely of graphite in order to be compatible with the LaB6 material, which cannot be touched by metals during operation due to boron diffusion causing embrittlement issues in high-temperature refractory materials. Also, the graphite tube was difficult to machine and was subject to vibration-induced fracturing. This innovation replaces the graphite tube with one made out of refractory metal that is relatively easy to manufacture. The cathode support tube is made of molybdenum or molybdenum-rhenium. This material is easily gun-bored to near the tolerances required, and finish machined with steps at each end that capture the orifice plate and the mounting flange. This provides the manufacturability and robustness needed for flight applications, and eliminates the need for expensive e-beam welding used in prior cathodes. The LaB6 insert is protected from direct contact with the refractory metal tube by thin, graphite sleeves in a cup-arrangement around the ends of the insert. The sleeves, insert, and orifice plate are held in place by a ceramic spacer and tungsten spring inserted inside the tube. To heat the cathode, an insulating tube is slipped around the refractory metal hollow tube, which can be made of high-temperature materials like boron nitride or aluminum nitride. A screw-shaped slot, or series of slots, is machined in the outside of the ceramic tube to constrain a refractory metal wire wound inside the slot that is used as the heater. The screw slot can hold a single heater wire that is then connected to the front of the cathode tube by tack-welding to complete the electrical circuit, or it can be a double slot that takes a bifilar wound heater with both leads coming out