WorldWideScience

Sample records for emission tomography synthese

  1. Distributed Microprocessor Automation Network for Synthesizing Radiotracers Used in Positron Emission Tomography [PET

    Science.gov (United States)

    Russell, J. A. G.; Alexoff, D. L.; Wolf, A. P.

    1984-09-01

    This presentation describes an evolving distributed microprocessor network for automating the routine production synthesis of radiotracers used in Positron Emission Tomography. We first present a brief overview of the PET method for measuring biological function, and then outline the general procedure for producing a radiotracer. The paper identifies several reasons for our automating the syntheses of these compounds. There is a description of the distributed microprocessor network architecture chosen and the rationale for that choice. Finally, we speculate about how this network may be exploited to extend the power of the PET method from the large university or National Laboratory to the biomedical research and clinical community at large. (DT)

  2. Positron emission tomography

    CERN Document Server

    Paans, A M J

    2006-01-01

    Positron Emission Tomography (PET) is a method for measuring biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides such as 11C, 13N, 15O and 18F and by measuring the annihilation radiation using a coincidence technique. This includes also the measurement of the pharmacokinetics of labelled drugs and the measurement of the effects of drugs on metabolism. Also deviations of normal metabolism can be measured and insight into biological processes responsible for diseases can be obtained. At present the combined PET/CT scanner is the most frequently used scanner for whole-body scanning in the field of oncology.

  3. Positron Emission Tomography (PET)

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs.

  4. Positron emission tomography basic sciences

    CERN Document Server

    Townsend, D W; Valk, P E; Maisey, M N

    2003-01-01

    Essential for students, science and medical graduates who want to understand the basic science of Positron Emission Tomography (PET), this book describes the physics, chemistry, technology and overview of the clinical uses behind the science of PET and the imaging techniques it uses. In recent years, PET has moved from high-end research imaging tool used by the highly specialized to an essential component of clinical evaluation in the clinic, especially in cancer management. Previously being the realm of scientists, this book explains PET instrumentation, radiochemistry, PET data acquisition and image formation, integration of structural and functional images, radiation dosimetry and protection, and applications in dedicated areas such as drug development, oncology, and gene expression imaging. The technologist, the science, engineering or chemistry graduate seeking further detailed information about PET, or the medical advanced trainee wishing to gain insight into the basic science of PET will find this book...

  5. Positron emission tomography/computed tomography scanning for ...

    African Journals Online (AJOL)

    making positron emission tomography (PET) an attractive alternative for ... 1Department of Surgery, Nelson R Mandela School of Medicine, College of Health Sciences, University of KwaZulu-Natal, ..... This emphasises the benefit of this hybrid.

  6. Positron emission tomography/computed tomography scanning for ...

    African Journals Online (AJOL)

    Background: Although the site of nosocomial sepsis in the critically ill ventilated patient is usually identifiable, it may remain occult, despite numerous investigations. The rapid results and precise anatomical location of the septic source using positron emission tomography (PET) scanning, in combination with computed ...

  7. Advanced Instrumentation for Positron Emission Tomography [PET

    Science.gov (United States)

    Derenzo, S. E.; Budinger, T. F.

    1985-04-01

    This paper summarizes the physical processes and medical science goals that underlay modern instrumentation design for Positron Emission Tomography. The paper discusses design factors such as detector material, crystalphototube coupling, shielding geometry, sampling motion, electronics design, time-of-flight, and the interrelationships with quantitative accuracy, spatial resolution, temporal resolution, maximum data rates, and cost.

  8. Positron Emission Tomography of the Heart

    Science.gov (United States)

    Schelbert, H. R.; Phelps, M. E.; Kuhl, D. E.

    1979-01-01

    Positron emission computed tomography (PCT) represents an important new tool for the noninvasive evaluation and, more importantly, quantification of myocardial performance. Most currently available techniques permit assessment of only one aspect of cardiac function, i.e., myocardial perfusion by gamma scintillation camera imaging with Thallium-201 or left ventricular function by echocardiography or radionuclide angiocardiography. With PCT it may become possible to study all three major segments of myocardial performance, i.e., regional blood flow, mechanical function and, most importantly, myocardial metabolism. Each of these segments can either be evaluated separately or in combination. This report briefly describes the principles and technological advantages of the imaging device, reviews currently available radioactive tracers and how they can be employed for the assessment of flow, function and metabolism; and, lastly, discusses possible applications of PCT for the study of cardiac physiology or its potential role in the diagnosis of cardiac disease.

  9. Motion correction in thoracic positron emission tomography

    CERN Document Server

    Gigengack, Fabian; Dawood, Mohammad; Schäfers, Klaus P

    2015-01-01

    Respiratory and cardiac motion leads to image degradation in Positron Emission Tomography (PET), which impairs quantification. In this book, the authors present approaches to motion estimation and motion correction in thoracic PET. The approaches for motion estimation are based on dual gating and mass-preserving image registration (VAMPIRE) and mass-preserving optical flow (MPOF). With mass-preservation, image intensity modulations caused by highly non-rigid cardiac motion are accounted for. Within the image registration framework different data terms, different variants of regularization and parametric and non-parametric motion models are examined. Within the optical flow framework, different data terms and further non-quadratic penalization are also discussed. The approaches for motion correction particularly focus on pipelines in dual gated PET. A quantitative evaluation of the proposed approaches is performed on software phantom data with accompanied ground-truth motion information. Further, clinical appl...

  10. Bayesian image reconstruction: Application to emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nunez, J.; Llacer, J.

    1989-02-01

    In this paper we propose a Maximum a Posteriori (MAP) method of image reconstruction in the Bayesian framework for the Poisson noise case. We use entropy to define the prior probability and likelihood to define the conditional probability. The method uses sharpness parameters which can be theoretically computed or adjusted, allowing us to obtain MAP reconstructions without the problem of the grey'' reconstructions associated with the pre Bayesian reconstructions. We have developed several ways to solve the reconstruction problem and propose a new iterative algorithm which is stable, maintains positivity and converges to feasible images faster than the Maximum Likelihood Estimate method. We have successfully applied the new method to the case of Emission Tomography, both with simulated and real data. 41 refs., 4 figs., 1 tab.

  11. Teflon laryngeal granuloma presenting as laryngeal cancer on combined positron emission tomography and computed tomography scanning.

    Science.gov (United States)

    Ondik, M P; Kang, J; Bayerl, M G; Bruno, M; Goldenberg, D

    2009-05-01

    Positron emission tomography with 18F-fluorodeoxyglucose (18FDG) has been increasingly used in the diagnostic investigation of patients with neoplasms of the head and neck. Positron emission tomography and computed tomography have also proven useful for surveillance of thyroid cancers that no longer concentrate radioiodine. However, certain benign or inflammatory lesions can also accumulate 18F-fluorodeoxyglucose and lead to misdiagnosis. We review and discuss the pitfalls of using positron emission tomography and computed tomography for surveillance of thyroid cancer. We present the case of a 48-year-old woman who was diagnosed with a laryngeal neoplasm on integrated positron emission tomography and computed tomography scanning, after a routine ultrasound demonstrated an enlarged thyroid nodule. On physical examination, she had a laryngeal mass overlying an immobile vocal fold. The mass was biopsied and found to harbour a Teflon granuloma. Positron emission tomography positive Teflon granulomas have previously been reported in the nasopharynx and vocal folds, and should be considered in the differential diagnosis of patients who have undergone prior surgery involving Teflon injection. It is important for otolaryngologists and radiologists to recognise potential causes of false positive positron emission tomography and computed tomography findings, including Teflon granulomas.

  12. Amorphous silicon detectors in positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Conti, M. (Istituto Nazionale di Fisica Nucleare, Pisa (Italy) Lawrence Berkeley Lab., CA (USA)); Perez-Mendez, V. (Lawrence Berkeley Lab., CA (USA))

    1989-12-01

    The physics of the detection process is studied and the performances of different Positron Emission Tomography (PET) system are evaluated by theoretical calculation and/or Monte Carlo Simulation (using the EGS code) in this paper, whose table of contents can be summarized as follows: a brief introduction to amorphous silicon detectors and some useful equation is presented; a Tantalum/Amorphous Silicon PET project is studied and the efficiency of the systems is studied by Monte Carlo Simulation; two similar CsI/Amorphous Silicon PET projects are presented and their efficiency and spatial resolution are studied by Monte Carlo Simulation, light yield and time characteristics of the scintillation light are discussed for different scintillators; some experimental result on light yield measurements are presented; a Xenon/Amorphous Silicon PET is presented, the physical mechanism of scintillation in Xenon is explained, a theoretical estimation of total light yield in Xenon and the resulting efficiency is discussed altogether with some consideration of the time resolution of the system; the amorphous silicon integrated electronics is presented, total noise and time resolution are evaluated in each of our applications; the merit parameters {epsilon}{sup 2}{tau}'s are evaluated and compared with other PET systems and conclusions are drawn; and a complete reference list for Xenon scintillation light physics and its applications is presented altogether with the listing of the developed simulation programs.

  13. Positron emission tomography in generalized seizures

    Energy Technology Data Exchange (ETDEWEB)

    Theodore, W.H.; Brooks, R.; Margolin, R.; Patronas, N.; Sato, S.; Porter, R.J.; Mansi, L.; Bairamian, D.; DiChiro, G.

    1985-05-01

    The authors used /sup 18/F-fluorodeoxyglucose (FDG) positron emission tomography (PET) to study nine patients with clinical absence or generalized seizures. One patient had only absence seizures, two had only generalized tonic-clonic seizures, and six had both seizure types. Interictal scans in eight failed to reveal focal or lateralized hypometabolism. No apparent abnormalities were noted. Two patients had PET scans after isotope injection during hyperventilation-induced generalized spike-wave discharges. Diffusely increased metabolic rates were found in one compared with an interictal scan, and in another compared with control values. Another patient had FDG injected during absence status: EEG showed generalized spike-wave discharges (during which she was unresponsive) intermixed with slow activity accompanied by confusion. Metabolic rates were decreased, compared with the interictal scan, throughout both cortical and subcortical structures. Interictal PET did not detect specific anatomic regions responsible for absence seizure onset in any patient, but the results of the ictal scans did suggest that pathophysiologic differences exist between absence status and single absence attacks.

  14. Obesity and Brain Positron Emission Tomography.

    Science.gov (United States)

    Pak, Kyoungjune; Kim, Seong-Jang; Kim, In Joo

    2018-02-01

    Obesity, an increasingly common problem in modern societies, results from energy intake chronically exceeding energy expenditure. This imbalance of energy can be triggered by the internal state of the caloric equation (homeostasis) and non-homeostatic factors, such as social, cultural, psychological, environmental factors or food itself. Nowadays, positron emission tomography (PET) radiopharmaceuticals have been examined to understand the cerebral control of food intake in humans. Using 15O-H2 PET, changes in regional cerebral blood flow (rCBF) coupled to neuronal activity were reported in states of fasting, satiation after feeding, and sensory stimulation. In addition, rCBF in obese subjects showed a greater increase in insula, the primary gustatory cortex. 18F-fluorodeoxyglucose PET showed higher metabolic activity in postcentral gyrus of the parietal cortex and lower in prefrontal cortex and anterior cingulate cortex in obese subjects. In addition, dopamine receptor (DR) PET demonstrated lower DR availability in obese subjects, which might lead to overeating to compensate. Brain PET has been utilized to reveal the connectivity between obesity and brain. This could improve understanding of obesity and help develop a new treatment for obesity.

  15. Microfluidics for Positron Emission Tomography Probe Development

    Directory of Open Access Journals (Sweden)

    Ming-Wei Wang

    2010-07-01

    Full Text Available Owing to increased needs for positron emission tomography (PET, high demands for a wide variety of radiolabeled compounds will have to be met by exploiting novel radiochemistry and engineering technologies to improve the production and development of PET probes. The application of microfluidic reactors to perform radiosyntheses is currently attracting a great deal of interest because of their potential to deliver many advantages over conventional labeling systems. Microfluidics-based radiochemistry can lead to the use of smaller quantities of precursors, accelerated reaction rates, and easier purification processes with greater yield and higher specific activity of desired probes. Several proof-of-principle examples along with the basics of device architecture and operation and the potential limitations of each design are discussed. Along with the concept of radioisotope distribution from centralized cyclotron facilities to individual imaging centers and laboratories (“decentralized model”, an easy-to-use, stand-alone, flexible, fully automated, radiochemical microfluidic platform can provide simpler and more cost-effective procedures for molecular imaging using PET.

  16. Positron emission tomography (PET): evaluation of chronic periaortitis

    National Research Council Canada - National Science Library

    Salvarani, Carlo; Pipitone, Nicolò; Versari, Annibale; Vaglio, Augusto; Serafini, Desiderio; Bajocchi, Gianluigi; Salvo, Diana; Buzio, Carlo; Greco, Paolo; Boiardi, Luigi

    2005-01-01

    ...)F-fluorodeoxyglucose-positron emission tomography (FDG-PET). A consecutive case series consisting of 7 patients with CP seen over a 3-year period and a control group of 14 patients with malignancy were evaluated with FDG-PET...

  17. Positron emission tomography: labelling with fluorine 18; Tomographie par emission de positons: les possibilites de marquage au fluor 18

    Energy Technology Data Exchange (ETDEWEB)

    Le Bars, D. [Cermep Imagerie du Vivant, 69 - Lyon (France)

    2005-04-15

    Fluorine 18 labelling of biological molecules leads to radiopharmaceuticals for positron emission tomography. besides [{sup 18}F]F.D.G., various chemical reactions enable development of new tracers. (author)

  18. Positron emission tomography/computed tomography for optimized colon cancer staging and follow up

    DEFF Research Database (Denmark)

    Engelmann, Bodil Elisabeth; Loft, Annika; Kjær, Andreas

    2014-01-01

    OBJECTIVES: Optimal management of colon cancer (CC) requires detailed assessment of extent of disease. This study prospectively investigates the diagnostic accuracy of 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography/computed tomography (PET/CT) for staging and detection of recurrence...

  19. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  20. An online emission spectral tomography system with digital signal processor.

    Science.gov (United States)

    Wan, Xiong; Xiong, Wenlin; Zhang, Zhimin; Chang, Fangfei

    2009-03-30

    Emission spectral tomography (EST) has been adopted to test the three-dimensional distribution parameters of fluid fields, such as burning gas, flame and plasma etc. In most cases, emission spectral data received by the video cameras are enormous so that the emission spectral tomography calculation is often time-consuming. Hence, accelerating calculation becomes the chief factor that one must consider for the practical application of EST. To solve the problem, a hardware implementation method was proposed in this paper, which adopted a digital signal processor (DSP) DM642 in an emission spectral tomography test system. The EST algorithm was fulfilled in the DSP, then calculation results were transmitted to the main computer via the user datagram protocol. Compared with purely VC++ software implementations, this new approach can decrease the calculation time significantly.

  1. Positron emission tomography and migraine. Tomographie par emission de positons et migraine

    Energy Technology Data Exchange (ETDEWEB)

    Chabriat, H. (CEA, 91 - Orsay (France). Service Hospitalier Frederic Joliot)

    1992-04-01

    Positron emission tomography (PET) is a brain imaging technique that allows in vivo studies of numerous physiological parameters. There have been few PET studies in migraine patients. Cerebral blood flow changes with no variations in brain oxygen consumption have been reported in patients with prolonged neurologic manifestations during migraine attacks. Parenteral administration of reserpine during migraine headache has been followed by a fall in the overall cerebral uptake of glucose. The small sample sizes and a number of methodologic problems complicate the interpretation of these results. Recent technical advances and the development of new PET tracers can be expected to provide further insight into the pathophysiology of migraine. Today cerebral cortex 5 HT{sub 2} serotonin receptors can be studied in migraine patients with PET.

  2. Monte Carlo Simulation of Emission Tomography and other Medical Imaging Techniques

    Science.gov (United States)

    Harrison, Robert L.

    2010-01-01

    As an introduction to Monte Carlo simulation of emission tomography, this paper reviews the history and principles of Monte Carlo simulation, then applies these principles to emission tomography using the public domain simulation package SimSET (a Simulation System for Emission Tomography) as an example. Finally, the paper discusses how the methods are modified for X-ray computed tomography and radiotherapy simulations.

  3. Introducing Positron Emission Tomography (PET) in Clinical Practice

    OpenAIRE

    Janevik-Ivanovska, Emilija; Avmedovski, Fatmir; YAMAMOTO, Mayumi; Bhonsle, Uday

    2009-01-01

    Positron emission tomography (PET) is a major diagnostic imaging technique predominantly used in determining the presence and severity of cancers, neurological conditions, and cardiovascular diseases. It is currently the most effective way to check for cancer recurrences and it offers significant advantages over other forms of imaging such as computed tomography (CT) or magnetic resonance imaging (MRI) scans in detecting disease in many patients. In the USA, an estimated 1 129 900 clinical PE...

  4. Gliomatosis cerebri mimicking encephalitis evaluated using fluorine-18 fluorodeoxyglucose: Positron emission tomography/computed tomography.

    Science.gov (United States)

    Kamaleshwaran, Koramadai Karuppusamy; Krishnan, Vijayan; Mohanan, Vyshakh; Shibu, Deepu; Shinto, Ajit Sugunan

    2015-01-01

    Gliomatosis cerebri (GC) is a rare condition in which an infiltrative glial neoplasm spreads through the brain with preservation of the underlying structure. F-18 fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) has an important role in demonstrating the appropriate metabolism and differentiating pathologies mimicking GC on CT and magnetic resonance imaging. We describe imaging findings of FDG PET/CT in GC in a 9-year-old male child mimicking encephalitis.

  5. Cardiac investigations with positron emission tomography;Les examens cardiaques en tomographie par emission de positons

    Energy Technology Data Exchange (ETDEWEB)

    Marie, P.Y.; Djaballah, W.; Didot, N.; Karcher, G. [CHU de Nancy, Service de medecine nucleaire, hopital de Brabois, 54 - Vandoeuvre (France); Marie, P.Y.; Djaballah, W.; Didot, N.; Karcher, G. [Universite de Nancy, Faculte de medecine, 54 - Nancy (France); Marie, P.Y. [Inserm U961, 54 - Nancy (France); Djaballah, W. [Inserm U947, 54 - Nancy (France)

    2010-03-15

    Cardiac positron emission tomography (PET) is yet considered as a reference imaging technique but remains poorly used in clinical practice. At the present time, the advantages of cardiac PET investigations are far to be evident, when compared with conventional tomo-scintigraphy (SPECT), except for perfusion imaging in the obese and for viability assessment in case of very severe cardiac dysfunction. However, this situation might quickly move because of an enhanced availability of PET imaging, dramatic technical progresses and promising new tracers. In particular, the last-generation PET-cameras allow reaching spatial resolutions and detection sensitivities, which are now spectacularly higher than those from conventional SPECT imaging. In addition, the list mode recording allows the subsequent images reconstruction to be synchronized to cardiac cycle but also to respiratory cycle; and the quantifications of myocardial perfusion flow and of coronary flow reserve are now available in clinical routine. Furthermore, new tracers labelled with fluorine-18 are under development, especially for perfusion investigations, and kinetics properties of these new tracers are dramatically enhanced when compared with current perfusion SPECT tracers. (authors)

  6. Detection of unknown occult primary tumors using positron emission tomography

    NARCIS (Netherlands)

    Kole, AC; Nieweg, OE; Pruim, J; Hoekstra, HJ; Roodenburg, JLN; Vaalburg, W; Vermey, A; Schraffordt Koops, H.

    1998-01-01

    BACKGROUND. The potential of positron emission tomography (PET) with F-18-fluoro-2-deoxy-D-glucose (FDG) to detect primary tumors after unsuccessful conventional diagnostic workup was assessed in patients with metastatic disease from an unknown primary tumor. METHODS. Twenty-nine patients with

  7. Recent Developments in Positron Emission Tomography (PET) Instrumentation

    Science.gov (United States)

    Derenzo, S. E.; Budinger, T. F.

    1986-04-01

    This paper presents recent detector developments and perspectives for positron emission tomography (PET) instrumentation used for medical research, as well as the physical processes in positron annihilation, photon scattering and detection, tomograph design considerations, and the potentials for new advances in detectors.

  8. Recent developments in positron emission tomography (PET) instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Derenzo, S.E.; Budinger, T.F.

    1986-04-01

    This paper presents recent detector developments and perspectives for positron emission tomography (PET) instrumentation used for medical research, as well as the physical processes in positron annihilation, photon scattering and detection, tomograph design considerations, and the potentials for new advances in detectors. 117 refs., 4 figs., 4 tabs.

  9. 64Cu loaded liposomes as positron emission tomography imaging agents

    DEFF Research Database (Denmark)

    Petersen, Anncatrine Luisa; Binderup, Tina; Rasmussen, Palle

    2011-01-01

    We have developed a highly efficient method for utilizing liposomes as imaging agents for positron emission tomography (PET) giving high resolution images and allowing direct quantification of tissue distribution and blood clearance. Our approach is based on remote loading of a copper-radionuclid...

  10. Sentence comprehension and word repetition : A positron emission tomography investigation

    NARCIS (Netherlands)

    Stowe, L.A.; Paans, A.M.J.; Wijers, A.A.; Zwarts, F.; Mulder, G.; Vaalburg, W.

    1999-01-01

    Using positron emission tomography, visual presentation of sentences was shown to cause increased regional cerebral blood flow relative to word Lists in the left lateral anterior superior and middle temporal gyri, attributable to cognitive processes that occur during sentence comprehension in

  11. Hybrid Gama Emission Tomography (HGET): FY16 Annual Report

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Erin A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Smith, Leon E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wittman, Richard S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Campbell, Luke W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Deshmukh, Nikhil S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Zalavadia, Mital A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Batie, Margo A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Mozin, Vladimir V. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-02-01

    Current International Atomic Energy Agency (IAEA) methodologies for the verification of fresh low-enriched uranium (LEU) and mixed oxide (MOX) fuel assemblies are volume-averaging methods that lack sensitivity to individual pins. Further, as fresh fuel assemblies become more and more complex (e.g., heavy gadolinium loading, high degrees of axial and radial variation in fissile concentration), the accuracy of current IAEA instruments degrades and measurement time increases. Particularly in light of the fact that no special tooling is required to remove individual pins from modern fuel assemblies, the IAEA needs new capabilities for the verification of unirradiated (i.e., fresh LEU and MOX) assemblies to ensure that fissile material has not been diverted. Passive gamma emission tomography has demonstrated potential to provide pin-level verification of spent fuel, but gamma-ray emission rates from unirradiated fuel emissions are significantly lower, precluding purely passive tomography methods. The work presented here introduces the concept of Hybrid Gamma Emission Tomography (HGET) for verification of unirradiated fuels, in which a neutron source is used to actively interrogate the fuel assembly and the resulting gamma-ray emissions are imaged using tomographic methods to provide pin-level verification of fissile material concentration.

  12. Positron emission tomography makes cerebral metabolism visible

    Energy Technology Data Exchange (ETDEWEB)

    Meermann, H.

    1982-05-12

    In the present publication the principle and advantage of positron emission topography as a nuclear medical method for the diagnosis of brain diseases are described. By this method the metabolic processes in the brain are measured using labelled compounds which are actively metabolized in the brain. These are for instance glucose, aminoacids and psychopharmaceutics, whose main site of action is in the brain. Thus not only tumorous processes but also regional blood circulation, oxygen absorption, regional protein synthesis, distribution and utilization of carrier substances and the absorption of drugs can be established.

  13. Multifocal sparganosis mimicking lymphoma involvement: Multimodal imaging findings of ultrasonography, CT, MRI, and position emission tomography-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Heo, So Young; Park, Ji Yeon; Park, Noh Hyuck; Park, Chan Sub; Kim, Tae Jung [Myongji Hospital, Seonam University College of Medicine, Goyang (Korea, Republic of); Yi, Seong Yoon [Dev. of Hematology-Omcology, Dept. of Internal Medicine, Inje University Ilsan Paik Hospital, Goyang (Korea, Republic of); Jun, Hyun Jung [Dev. of Hematology-Omcology, Dept. of Internal Medicine, Seoul Medical Center, Seoul (Korea, Republic of)

    2016-01-15

    Sparganosis is a rare parasitic disease caused by the migrating plerocercoid larva of Spirometra species tapeworms. The most frequent clinical manifestation is a subcutaneous nodule resembling a neoplasm. In this study, we presented multimodal findings of ultrasonography, computed tomography, magnetic resonance imaging, positron emission tomography-computed tomography and follow-up imagings on multifocal sparganosis, mimicking lymphoma involvement in a patient with lymphoma.

  14. Imaging opiate receptors with positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Frost, J.J.; Dannals, R.F.; Ravert, H.T.; Wilson, A.A.; Wong, D.F.; Links, J.M.; Burns, H.D.; Kuhar, M.J.; Snyder, S.H.; Wagner, H.N. Jr.

    1984-01-01

    Opiate receptors exist in the mammalian brain and are thought to meditate the diverse pharmacological actions of the opiates, such as analgesia, euphoria, and sedation. The 4-carbomethoxyl derivatives of fentanyl, such as lofentanil and R31833 (4-carbomethoxyfentanyl) bind to the opiate receptor with high affinity. C-11 R31833 was synthesized by reacting C-11 methyl iodide with the appropriate carboxylate. Male ICR mice were injected intravenously with C-11 R31833 (5..mu..g/kg), killed 30 minutes later, and the brains rapidly dissected. The thalami, striata, and cerebral cortex are rich in opiate receptors, but the cerebellum contains a very low concentration of opiate receptors. The thalamus/cerebellum and striatum/cerebellum activity ratios, calculated per mg of wet tissue, were 4.1 and 5.2 respectively. Coinjection of 5mg/kg naloxone reduced the ratios to 1.1, which indicates that the preferential localization of C-11 R31833 in the thalami and striata is due to binding to opiate is due to binding to opiate receptors. A 22 kg anesthetized male baboon was imaged using the NeuroECAT after injection of 18.9 mCi of C-11 R13833 (0.50 ..mu..g/kg, specific activity 616 Ci/mmole at time of injection). From 15-70 minutes after injection preferential accumulation of activity could be seen in the thalami, caudate nuclei, and cerebral cortex and, conversely, low activity was demonstrated in the cerebellum. At one hour postinjection the maximum measured caudate/cerebellum activity ratio per pixel was 2.9. For the NeuroECAT the recovery coefficient for the baboon caudate is ca. 0.2-0.3, and therefore the actual caudate/cerebellum ratio is ca. 10-15.

  15. ENVISION, developing Positron Emission Tomography for particle therapy

    CERN Multimedia

    2013-01-01

    Particle therapy is an advanced technique of cancer radiation therapy, using protons or other ions to target the cancerous mass. ENVISION aims at developing medical imaging tools to improve the dose delivery to the patient, to ensure a safer and more effective treatment. The animation illustrates the use of Positron Emission Tomography (PET) for monitoring the dose during treatment. Produced by: CERN KT/Life Sciences and ENVISION Project Management: Manuela Cirilli 3D animation: Jeroen Huijben, Nymus3d

  16. Simultaneous in vivo positron emission tomography and magnetic resonance imaging

    OpenAIRE

    Catana, Ciprian; Procissi, Daniel; Wu, Yibao; Judenhofer, Martin S.; Qi, Jinyi; Pichler, Bernd J.; Jacobs, Russell E.; Cherry, Simon R.

    2008-01-01

    Positron emission tomography (PET) and magnetic resonance imaging (MRI) are widely used in vivo imaging technologies with both clinical and biomedical research applications. The strengths of MRI include high-resolution, high-contrast morphologic imaging of soft tissues; the ability to image physiologic parameters such as diffusion and changes in oxygenation level resulting from neuronal stimulation; and the measurement of metabolites using chemical shift imaging. PET images the distribution o...

  17. Fast Neutron Emission Tomography of Used Nuclear Fuel Assemblies

    Science.gov (United States)

    Hausladen, Paul; Iyengar, Anagha; Fabris, Lorenzo; Yang, Jinan; Hu, Jianwei; Blackston, Matthew

    2017-09-01

    Oak Ridge National Laboratory is developing a new capability to perform passive fast neutron emission tomography of spent nuclear fuel assemblies for the purpose of verifying their integrity for international safeguards applications. Most of the world's plutonium is contained in spent nuclear fuel, so it is desirable to detect the diversion of irradiated fuel rods from an assembly prior to its transfer to ``difficult to access'' storage, such as a dry cask or permanent repository, where re-verification is practically impossible. Nuclear fuel assemblies typically consist of an array of fuel rods that, depending on exposure in the reactor and consequent ingrowth of 244Cm, are spontaneous sources of as many as 109 neutrons s-1. Neutron emission tomography uses collimation to isolate neutron activity along ``lines of response'' through the assembly and, by combining many collimated views through the object, mathematically extracts the neutron emission from each fuel rod. This technique, by combining the use of fast neutrons -which can penetrate the entire fuel assembly -and computed tomography, is capable of detecting vacancies or substitutions of individual fuel rods. This paper will report on the physics design and component testing of the imaging system. This material is based upon work supported by the U.S. Department of Energy, Office of Defense Nuclear Nonproliferation Research and Development within the National Nuclear Security Administration, under Contract Number DE-AC05-00OR22725.

  18. Fabrication of polycrystalline scintillators for the positron emission tomography (PET); Herstellung polykristalliner Szintillatoren fuer die Positronen-Emissions-Tomographie (PET)

    Energy Technology Data Exchange (ETDEWEB)

    Karim, Kamran Said

    2010-07-01

    Transparent ceramics are becoming more and more important for two new types of applications. On the one hand in cases where high mechanical and thermal demands in combination with optical properties are required, on the other hand where the optical properties of transparent materials like glass are not sufficient e.g. in positron-emission-tomography (PET) diagnostics. Most state of the art PET-scanners are using high-priced single crystals as scintillator material. The technological challenge is to replace single crystal by cost-efficient transparent ceramics. Producing transparent ceramics is ordered in synthesis of the powders and in manufacturing of these into transparent ceramics. The aim of this work was to synthesize single phase yttrium-alumina-and Luthetiumalumina-garnet (YAG, LuAG) powders partially doped with neodymium or praseodymium by four different synthesis routes (Pechini-synthesis, sol-gel-route, coprecipitation and solid state reactions). Additionally industrial LuAG and LuPO{sub 4} powders were characterized and manufactured. The powders were processed as submicron- and nanopowders. The compaction of nanopowder greenbodies sintered at high temperatures leads to a ''cross-over'' between both manufacturing route. Newly produced single-phase powders were homogenized with additions of sintering additives like tetraethyl orthosilicate (TEOS) and binders like polyvinyl alcohol (PVA). Moulding the powders were carried out by uniaxial pressing, cold isostatic pressing and in individual cases also by slip casting. The achieved green densities were in a range of 25-42 %. Examination of calcination behaviour leads to a calcination temperature of 1000 C with 2 hours dwell time in air atmosphere. Only solid state reactions resulted into transparent YAG, YAG:Pr, LuAG, LuAG:Pr ceramics. Solid state reactions of nanopowders resulted in heterogeneously transparent samples. Ceramics made by powders of other synthetic routes gave nontransparent

  19. Differentiation of retroperitoneal tumor using positron emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Buonocore, E.; Huebner, K.F.; Collmann, I.R.

    1979-12-01

    Positron emission computed tomography (ECT) with /sup 11/C-DL-tryptophan and /sup 11/C-aminocyclobutanecarboxylic acid (/sup 11/C-ACBC) has produced some promising results in patients with retroperitoneal masses. This brief report gives an example of one patient in whom a retroperitoneal mass could not be differentiated from the pancreas by transmission computed tomography but was suspected to be of pancreatic origin based on arteriographic findings. The ECT scans with /sup 11/C-DL-tryptophan showed a normal pancreas, whereas the tumor localizing agent /sup 11/C-ACBC concentrated in a tumor surrounding the tail and body of the pancreas. This approach with dual radiopharmaceuticals for the differentiation of metabolically active neoplasms and normal tissues warrants further investigation.

  20. Positron emission tomography of incidentally detected small pulmonary nodules

    DEFF Research Database (Denmark)

    Fischer, B M; Mortensen, J; Dirksen, A

    2004-01-01

    from an ongoing 4-year placebo controlled intervention study of the effect of inhaled steroids in 300 smokers with moderate to severe chronic obstructive pulmonary disease. The participants received yearly CT scans of the chest. Patients with a negative chest radiograph at the time of inclusion......The aim of this study was to assess the value of fluorodeoxyglucose positron emission tomography (FDG PET) imaging of small pulmonary nodules incidentally detected by spiral computed tomography (CT) in a high-risk population. Ten patients (five females, five males, aged 54-72 years) were recruited......, but with pulmonary nodules indeterminate for malignancy detected by conventional spiral CT on a subsequent scan, were referred for FDG PET. Histological diagnoses were sought for all nodules with FDG uptake or where CT showed that they had grown. Ten patients had pulmonary nodules indeterminate for malignancy...

  1. [Positron emission tomography (PET) in gastro-intestinal cancer].

    Science.gov (United States)

    Wartski, Myriam

    2016-09-01

    The existing recommendations for fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) use in digestive cancers (excluding neuroendocrine tumours) are summarized in the present article. FDG-PET/CT is nowadays a routine imaging modality for digestive malignancies and its use is currently increasing. FDG-PET/CT is considered to be a crucial tool in pretherapeutic assessment of esophageal, localized pancreatic and anal cancer. It represents a key exam in suspicion of recurrence of colorectal cancer in case of elevated serum tumor markers. New data are emerging regarding FDG-PET/CT in therapeutic efficacy assessment, radiotherapy treatment planning and detection of recurrence in many digestive cancers. Incidental focal colonic FDG uptake has to be explored by colonoscopy, as often associated with premalignant or malignant lesions. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  2. Imaging prostate cancer: an update on positron emission tomography and magnetic resonance imaging

    DEFF Research Database (Denmark)

    Bouchelouche, Kirsten; Turkbey, Baris; Choyke, Peter

    2010-01-01

    , and molecular imaging information. Developments in imaging technologies, specifically magnetic resonance imaging (MRI) and positron emission tomography (PET)/computed tomography (CT), have improved the detection rate of prostate cancer. MRI has improved lesion detection and local staging. Furthermore, MRI...

  3. Emission computerized myocardial tomography with the 7-pinhole collimator

    Energy Technology Data Exchange (ETDEWEB)

    Sochor, H.; Pachinger, O.; Ogris, E.; Probst, P.; Joskowicz, G.; Kaindl, F. (Vienna Univ. (Austria). Kardiologische Klinik)

    1983-01-01

    89 patients (78 with coronary artery disease, 11 normals) were studied comparatively with Tl-201 planar myocardial scintigraphy and 7-pinhole emission tomography with a mobile gamma-camera. In 46 patients stress studies were performed, the other studies were performed as resting protocols. In 13 patients a correlation of scintigraphically determined infarct size calculated from the Tl-201 tomograms with CK and CK-MB values (maximum values) in the acute infarction period was performed. 17 patients having undergone intracoronary streptolysis were studied to investigate the effect of this intervention. In patients without previous myocardial infarction (n=35) sensitivity of 7-pinhole tomography was significantly superior over planar reading of images (83% for qualitative evaluation, 91% for quantitative analysis). In patients with previous myocardial infarction (n=26) comparative sensitivities were not significantly different, although slightly higher, neverthelesss the fraction of questionable findings was reduced from 9 to 4%, furthermore in 31% an additional information concerning size or localization could be obtained from the tomograms. Predictive diagnostic accuracy was highest for quantitative 7-pinhole tomography (91%) but not significantly different from qualitative tomography but higher than for planar imaging. Specificities of all methods were comparable. In patients during the acute phase of myocardial infarction a significant correlation (r = 0.76 for CK, r = 0.78 for CK-MB, p < 0.01) was obtained with enzymatic markers of infarct size. In the group after intracoronary streptolysis 7-pinhole tomography was able to demonstrate a quantitative reduction of thallium infarct size in patients after successful lysis (23.5% vs 48.7%, p < 0.01).

  4. Positron Emission Tomography (PET) and breast cancer in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Lavayssiere, Robert [Centre d' Imagerie Paris-Nord, 1, avenue Charles Peguy, 95200 Sarcelles (France); Institut du Sein Henri Hartmann (ISHH), 1, rue des Dames Augustines, 92200 Neuilly sur Seine (France)], E-mail: cab.lav@wanadoo.fr; Cabee, Anne-Elizabeth [Centre d' Imagerie Paris-Nord, 1, avenue Charles Peguy, 95200 Sarcelles (France); Institut du Sein Henri Hartmann (ISHH), 1, rue des Dames Augustines, 92200 Neuilly sur Seine (France); Centre RMX, 80, avenue Felix Faure, 75105 Paris (France); Filmont, Jean-Emmanuel [Institut du Sein Henri Hartmann (ISHH), 1, rue des Dames Augustines, 92200 Neuilly sur Seine (France); American Hospital of Paris, Nuclear Medicine, 63, boulevard Victor Hugo - BP 109, 92202 Neuilly sur Seine Cedex (France)

    2009-01-15

    The landscape of oncologic practice has changed deeply during the past few years and there is now a need, through a multidisciplinary approach, for imaging to provide accurate evaluation of morphology and function and to guide treatment (Image Guided Therapy). Increasing emphasis has been put on Position Emission Tomography (PET) role in various cancers among clinicians and patients despite a general context of healthcare expenditure limitation. Positron Emission Tomography has currently a limited role in breast cancer, but also general radiologists and specialists should be aware of these indications, especially when staging aggressive cancers and looking for recurrence. Currently, the hybrid systems associating PET and Computed Tomography (CT) and in the same device [Rohren EM, Turkington TG, Coleman RE. Clinical applications of PET in oncology. Radiology 2004;231:305-32; Blodgett TM, Meltzer CM, Townsend DW. PET/CT: form and function. Radiology 2007;242:360-85; von Schulthess GK, Steinert HC, Hany TF. Integrated PET/CT: current applications and futures directions. Radiology 2006;238(2):405-22], or PET-CT, are more commonly used and the two techniques are adding their potentialities. Other techniques, MRI in particular, may also compete with PET in some instance and as far as ionizing radiations dose limitation is considered, some breast cancers becoming some form of a chronic disease. Breast cancer is a very complex, non-uniform, disease and molecular imaging at large may contribute to a better knowledge and to new drugs development. Ongoing research, Positron Emission Mammography (PEM) and new tracers, are likely to bring improvements in patient care [Kelloff GJ, Hoffman JM, Johnson B, et al. Progress and promise of FDG-PET Imaging for cancer patient management and oncologic drug development. Clin Cancer Res 2005;1(April (8)): 2005].

  5. Direct conversion semiconductor detectors in positron emission tomography

    Science.gov (United States)

    Cates, Joshua W.; Gu, Yi; Levin, Craig S.

    2015-05-01

    Semiconductor detectors are playing an increasing role in ongoing research to improve image resolution, contrast, and quantitative accuracy in preclinical applications of positron emission tomography (PET). These detectors serve as a medium for direct detection of annihilation photons. Early clinical translation of this technology has shown improvements in image quality and tumor delineation for head and neck cancers, relative to conventional scintillator-based systems. After a brief outline of the basics of PET imaging and the physical detection mechanisms for semiconductor detectors, an overview of ongoing detector development work is presented. The capabilities of semiconductor-based PET systems and the current state of these devices are discussed.

  6. Routine Bone Marrow Biopsy Has Little or No Therapeutic Consequence for Positron Emission Tomography/Computed Tomography-Staged Treatment-Naive Patients With Hodgkin Lymphoma

    DEFF Research Database (Denmark)

    El-Galaly, Tarec Christoffer; d´Amore, Francesco; Juul Mylam, Karen

    2012-01-01

    Routine Bone Marrow Biopsy Has Little or No Therapeutic Consequence for Positron Emission Tomography/Computed Tomography-Staged Treatment-Naive Patients With Hodgkin Lymphoma......Routine Bone Marrow Biopsy Has Little or No Therapeutic Consequence for Positron Emission Tomography/Computed Tomography-Staged Treatment-Naive Patients With Hodgkin Lymphoma...

  7. Acute Calculous Cholecystitis Missed on Computed Tomography and Ultrasound but Diagnosed with Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography.

    Science.gov (United States)

    Aparici, Carina Mari; Win, Aung Zaw

    2016-01-01

    We present a case of a 69-year-old patient who underwent ascending aortic aneurysm repair with aortic valve replacement. On postsurgical day 12, he developed leukocytosis and low-grade fevers. The chest computed tomography (CT) showed a periaortic hematoma which represents a postsurgical change from aortic aneurysm repair, and a small pericardial effusion. The abdominal ultrasound showed cholelithiasis without any sign of cholecystitis. Finally, a fluorodeoxyglucose (FDG)-positron emission tomography (PET)/CT examination was ordered to find the cause of fever of unknown origin, and it showed increased FDG uptake in the gallbladder wall, with no uptake in the lumen. FDG-PET/CT can diagnose acute cholecystitis in patients with nonspecific clinical symptoms and laboratory results.

  8. Acute Calculous Cholecystitis Missed on Computed Tomography and Ultrasound but Diagnosed with Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Carina Mari Aparici

    2016-01-01

    Full Text Available We present a case of a 69-year-old patient who underwent ascending aortic aneurysm repair with aortic valve replacement. On postsurgical day 12, he developed leukocytosis and low-grade fevers. The chest computed tomography (CT showed a periaortic hematoma which represents a postsurgical change from aortic aneurysm repair, and a small pericardial effusion. The abdominal ultrasound showed cholelithiasis without any sign of cholecystitis. Finally, a fluorodeoxyglucose (FDG-positron emission tomography (PET/CT examination was ordered to find the cause of fever of unknown origin, and it showed increased FDG uptake in the gallbladder wall, with no uptake in the lumen. FDG-PET/CT can diagnose acute cholecystitis in patients with nonspecific clinical symptoms and laboratory results.

  9. Clinical Pearls: Etiologies of Superscan Appearance on Fluorine-18-Fludeoxyglucose Positron Emission Tomography-Computed Tomography.

    Science.gov (United States)

    Manov, John Joseph; Roth, Patrick J; Kuker, Russ

    2017-01-01

    The term "superscan" usually refers to a characteristic pattern on skeletal scintigraphy consisting of symmetrically intense and diffuse radiotracer uptake in the skeleton with absent or diminished visualization of the genitourinary system and soft tissues. Superscans and superscan-like appearances have also been described on fluorine-18-fludeoxyglucose positron emission tomography-computed tomography (18-F-FDG PET/CT). We review reported cases of 18-F-FDG PET/CT superscans and propose criteria for differentiating pathologic superscans from physiologic causes. Knowledge of the 18-F-FDG PET/CT superscan, its reported pathologic causes, its benign imitators, and its clinical implications is important to the nuclear medicine physician or radiologist specializing in the interpretation of nuclear studies to avoid several diagnostic pitfalls.

  10. Prognostic Evaluation of 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in Endometrial Cancer

    DEFF Research Database (Denmark)

    Vilstrup, Mie Holm; Jochumsen, Kirsten M; Hess, Søren

    2017-01-01

    OBJECTIVE: This study aims to ascertain if semiquantitative measurements derived from F-fluorodeoxyglucose positron emission tomography/computed tomography can be used as prognostic markers in patients with newly diagnosed endometrial cancer. MATERIALS AND METHODS: Patients with endometrial cancer...... proportional regression models were used for prognostic evaluation. RESULTS: Eighty-three patients (median age, 69.9 y; range, 26.8-91.1) with primarily high-risk endometrial cancer or suspected high The International Federation of Gynecology and Obstetrics stage were included. Mean follow-up time was 3......-risk endometrial cancer. Thus, SUVmax and cTLG might help identify patients who could benefit from a more aggressive treatment strategy or closer surveillance....

  11. Fasciola Hepatica Mimicking Malignancy on 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Erdem Sürücü

    2016-10-01

    Full Text Available A 48-year-old female with complaints of gastrointestinal symptoms such as abdominal pain, fatigue, vomiting, nausea, and weight loss was diagnosed with neuroendocrine tumor after removal of a 2 mm lesion from the stomach with endoscopic biopsy. Her magnetic resonance imaging that was performed due to on-going symptoms showed multiple linear hypointense lesions in the liver. Positron emission tomography/computed tomography (PET/CT scan was performed for differential diagnosis, which showed high fluorodeoxyglucose (FDG uptake in these lesions. Clinical and laboratory findings revealed the final diagnosis as Fasciola hepatica. The imaging features of this case is presented to aid in differentiating this infectious disease from malignancy and avoid misdiagnosis on FDG-PET/CT.

  12. In Vivo Treatment Sensitivity Testing With Positron Emission Tomography/Computed Tomography After One Cycle of Chemotherapy for Hodgkin Lymphoma

    DEFF Research Database (Denmark)

    Hutchings, Martin; Kostakoglu, Lale; Zaucha, Jan Maciej

    2014-01-01

    PURPOSE: Negative [(18)F]fluorodeoxyglucose (FDG) -positron emission tomography (PET)/computed tomography (CT) after two cycles of chemotherapy indicates a favorable prognosis in Hodgkin lymphoma (HL). We hypothesized that the negative predictive value would be even higher in patients responding...

  13. Molecular Imaging of Transporters with Positron Emission Tomography

    Science.gov (United States)

    Antoni, Gunnar; Sörensen, Jens; Hall, Håkan

    Positron emission tomography (PET) visualization of brain components in vivo is a rapidly growing field. Molecular imaging with PET is also increasingly used in drug development, especially for the determination of drug receptor interaction for CNS-active drugs. This gives the opportunity to relate clinical efficacy to per cent receptor occupancy of a drug on a certain targeted receptor and to relate drug pharmacokinetics in plasma to interaction with target protein. In the present review we will focus on the study of transporters, such as the monoamine transporters, the P-glycoprotein (Pgp) transporter, the vesicular monoamine transporter type 2, and the glucose transporter using PET radioligands. Neurotransmitter transporters are presynaptically located and in vivo imaging using PET can therefore be used for the determination of the density of afferent neurons. Several promising PET ligands for the noradrenaline transporter (NET) have been labeled and evaluated in vivo including in man, but a really useful PET ligand for NET still remains to be identified. The most promising tracer to date is (S,S)-[18F]FMeNER-D2. The in vivo visualization of the dopamine transporter (DAT) may give clues in the evaluation of conditions related to dopamine, such as Parkinson's disease and drug abuse. The first PET radioligands based on cocaine were not selective, but more recently several selective tracers such as [11C]PE2I have been characterized and shown to be suitable as PET radioligands. Although there are a large number of serotonin transporter inhibitors used today as SSRIs, it was not until very recently, when [11C]McN5652 was synthesized, that this transporter was studied using PET. New candidates as PET radioligands for the SERT have subsequently been developed and [11C]DASB and [11C]MADAM and their analogues are today the most promising ligands. The existing radioligands for Pgp transporters seem to be suitable tools for the study of both peripheral and central drug

  14. Single Photon Emission Tomography Imaging in Parkinsonian Disorders: A Review

    Directory of Open Access Journals (Sweden)

    Paul D. Acton

    2000-01-01

    Full Text Available Parkinsonian symptoms are associated with a number of neurodegenerative disorders, such as Parkinson’s disease, multiple system atrophy and progressive supranuclear palsy. Pathological evidence has shown clearly that these disorders are associated with a loss of neurons, particularly in the nigrostriatal dopaminergic pathway. Positron emission tomography (PET and single photon emission tomography (SPECT now are able to visualise and quantify changes in cerebral blood flow, glucose metabolism, and dopaminergic function produced by parkinsonian disorders. Both PET and SPECT have become important tools in the differential diagnosis of these diseases, and may have sufficient sensitivity to detect neuronal changes before the onset of clinical symptoms. Imaging is now being utilised to elucidate the genetic contribution to Parkinson’s disease, and in longitudinal studies to assess the efficacy and mode of action of neuroprotective drug and surgical treatments. This review summarises recent applications of SPECT imaging in the study of parkinsonian disorders, with particular reference to the increasing role it is playing in the understanding, diagnosis and management of these diseases.

  15. Positron Emission Tomography imaging with the SmartPET system

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, R.J. [Department of Physics, University of Liverpool, Liverpool, Merseyside L69 7ZE (United Kingdom)], E-mail: cooperrj@ornl.gov; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Grint, A.N.; Harkness, L.J.; Nolan, P.J.; Oxley, D.C.; Scraggs, D.P.; Mather, A.R. [Department of Physics, University of Liverpool, Liverpool, Merseyside L69 7ZE (United Kingdom); Lazarus, I.; Simpson, J. [STFC Daresbury Laboratory, Daresbury, Warrington, Cheshire WA4 4AD (United Kingdom)

    2009-07-21

    The Small Animal Reconstruction Tomograph for Positron Emission Tomography (SmartPET) project is the development of a small animal Positron Emission Tomography (PET) demonstrator based on the use of High-Purity Germanium (HPGe) detectors and state of the art digital electronics. The experimental results presented demonstrate the current performance of this unique system. By performing high precision measurements of one of the SmartPET HPGe detectors with a range of finely collimated gamma-ray beams the response of the detector as a function of gamma-ray interaction position has been quantified, facilitating the development of parametric Pulse Shape Analysis (PSA) techniques and algorithms for the correction of imperfections in detector performance. These algorithms have then been applied to data from PET imaging measurements using two such detectors in conjunction with a specially designed rotating gantry. In this paper we show how the use of parametric PSA approaches allows over 60% of coincident events to be processed and how the nature and complexity of an event has direct implications for the quality of the resulting image.

  16. Hydrogen-bond promoted nucleophilic fluorination: concept, mechanism and applications in positron emission tomography.

    Science.gov (United States)

    Lee, Ji-Woong; Oliveira, Maria Teresa; Jang, Hyeong Bin; Lee, Sungyul; Chi, Dae Yoon; Kim, Dong Wook; Song, Choong Eui

    2016-08-22

    Due to the tremendous interest in carbon-fluorine bond-forming reactions, research efforts in this area have been dedicated to the development of facile processes to synthesize small fluorine-containing organic molecules. Among others, PET (Positron Emission Tomography) is one of the most important applications of fluorine chemistry. Recognizing the specific requirements of PET processes, some groups have focused on fluorination reactions using alkali metal fluorides, particularly through SN2-type reactions. However, a common "misconception" about the role of protic solvents and hydrogen bonding interactions in this class of reactions has hampered the employment of these excellent promoters. Herein, we would like to review recent discoveries in this context, showing straightforward nucleophilic fluorination reactions using alkali metal fluorides promoted by protic solvents. Simultaneous dual activation of reacting partners by intermolecular hydrogen bonding and the enhancement of the "effective fluoride nucleophilicity", which is Nature's biocatalytic approach with the fluorinase enzyme, are the key to this unprecedentedly successful nucleophilic fluorination.

  17. Kinetic modeling in pre-clinical positron emission tomography.

    Science.gov (United States)

    Kuntner, Claudia

    2014-12-01

    Pre-clinical positron emission tomography (PET) has evolved in the last few years from pure visualization of radiotracer uptake and distribution towards quantification of the physiological parameters. For reliable and reproducible quantification the kinetic modeling methods used to obtain relevant parameters of radiotracer tissue interaction are important. Here we present different kinetic modeling techniques with a focus on compartmental models including plasma input models and reference tissue input models. The experimental challenges off deriving the plasma input function in rodents and the effect of anesthesia are discussed. Finally, in vivo application of kinetic modeling in various areas of pre-clinical research is presented and compared to human data. Copyright © 2014. Published by Elsevier GmbH.

  18. Determination of the attenuation map in emission tomography

    CERN Document Server

    Zaidi, H

    2002-01-01

    Reliable attenuation correction methods for quantitative emission computed tomography (ECT) require accurate delineation of the body contour and often necessitate knowledge of internal anatomical structure. Two broad classes of methods have been used to calculate the attenuation map referred to as "transmissionless" and transmission-based attenuation correction techniques. While calculated attenuation correction belonging to the first class of methods is appropriate for brain studies, more adequate methods must be performed in clinical applications where the attenuation coefficient distribution is not known a priori, and for areas of inhomogeneous attenuation such as the chest. Measured attenuation correction overcomes this problem and utilizes different approaches to determine this map including transmission scanning, segmented magnetic resonance images or appropriately scaled X-ray CT scans acquired either independently on separate or simultaneously on multimodality imaging systems. Combination of data acqu...

  19. Positron emission tomography in CNS drug discovery and drug monitoring.

    Science.gov (United States)

    Piel, Markus; Vernaleken, Ingo; Rösch, Frank

    2014-11-26

    Molecular imaging methods such as positron emission tomography (PET) are increasingly involved in the development of new drugs. Using radioactive tracers as imaging probes, PET allows the determination of the pharmacokinetic and pharmacodynamic properties of a drug candidate, via recording target engagement, the pattern of distribution, and metabolism. Because of the noninvasive nature and quantitative end point obtainable by molecular imaging, it seems inherently suited for the examination of a pharmaceutical's behavior in the brain. Molecular imaging, most especially PET, can therefore be a valuable tool in CNS drug research. In this Perspective, we present the basic principles of PET, the importance of appropriate tracer selection, the impact of improved radiopharmaceutical chemistry in radiotracer development, and the different roles that PET can fulfill in CNS drug research.

  20. A Case of Corticobasal Degeneration Studied with Positron Emission Tomography

    Directory of Open Access Journals (Sweden)

    H. Nagasawa

    1993-01-01

    Full Text Available We measured cerebral blood flow, oxygen metabolism, glucose utilization, and dopamine metabolism in the brain of a patient with corticobasal degeneration using positron emission tomography (PET. The clinical picture is distinctive, comprising features referable to both cortical and basal ganglionic dysfunction. Brain imagings of glucose and dopamine metabolism can demonstrate greater abnormalities in the cerebral cortex and in the striatum contralateral to the more affected side than those of blood flow and oxygen metabolism. This unique combination study measuring both cerebral glucose utilization and dopamine metabolism in the nigrostriatal system can provide efficient information about the dysfunctions which are correlated with individual clinical symptoms, and this study is essential to diagnosis of corticobasal degeneration.

  1. A Review on Segmentation of Positron Emission Tomography Images

    Science.gov (United States)

    Foster, Brent; Bagci, Ulas; Mansoor, Awais; Xu, Ziyue; Mollura, Daniel J.

    2014-01-01

    Positron Emission Tomography (PET), a non-invasive functional imaging method at the molecular level, images the distribution of biologically targeted radiotracers with high sensitivity. PET imaging provides detailed quantitative information about many diseases and is often used to evaluate inflammation, infection, and cancer by detecting emitted photons from a radiotracer localized to abnormal cells. In order to differentiate abnormal tissue from surrounding areas in PET images, image segmentation methods play a vital role; therefore, accurate image segmentation is often necessary for proper disease detection, diagnosis, treatment planning, and follow-ups. In this review paper, we present state-of-the-art PET image segmentation methods, as well as the recent advances in image segmentation techniques. In order to make this manuscript self-contained, we also briefly explain the fundamentals of PET imaging, the challenges of diagnostic PET image analysis, and the effects of these challenges on the segmentation results. PMID:24845019

  2. Positron emission tomography evaluation of sedative properties of antihistamines.

    Science.gov (United States)

    Yanai, Kazuhiko; Zhang, Dongying; Tashiro, Manabu; Yoshikawa, Takeo; Naganuma, Fumito; Harada, Ryuichi; Nakamura, Tadaho; Shibuya, Katsuhiko; Okamura, Nobuyuki

    2011-07-01

    H(1) antihistamines are often used in the medication for allergic diseases, coughs and colds, and insomnia, with or without prescription, even though their sedative properties are a potentially dangerous unwanted side effect that is not properly recognized. These sedative properties have been evaluated using the incidence of subjective sleepiness, objective cognitive and psychomotor functions, and positron emission tomography (PET) measurement of H(1) receptor occupancy. This article reviews the current updated literature on the sedative properties of antihistamines examined by PET measurement of H(1) receptor occupancy. The use of PET to examine antihistamine penetration in the human brain in relation to psychometric and other functional measures of CNS effects is a major breakthrough and provides a new standard by which the functional CNS effects of antihistamines can be related directly to H(1) receptor occupancy. Therapy with antihistamines can be better guided by considering histamine H(1) receptor occupancy from the view of their sedative properties.

  3. Methodological review on functional neuroimaging using positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hae Jeong [Yonsei University, College of Medicine, Seoul (Korea, Republic of)

    2007-04-15

    Advance of neuroimaging technique has greatly influenced recent brain research field. Among various neuroimaging modalities, positron emission tomography has played a key role in molecular neuroimaging though functional MRI has taken over its role in the cognitive neuroscience. As the analysis technique for PET data is more sophisticated, the complexity of the method is more increasing. Despite the wide usage of the neuroimaging techniques, the assumption and limitation of procedures have not often been dealt with for the clinician and researchers, which might be critical for reliability and interpretation of the results. In the current paper, steps of voxel-based statistical analysis of PET including preprocessing, intensity normalization, spatial normalization, and partial volume correction will be revisited in terms of the principles and limitations. Additionally, new image analysis techniques such as surface-based PET analysis, correlational analysis and multimodal imaging by combining PET and DTI, PET and TMS or EEG will also be discussed.

  4. Temporoparietal cortex in aphasia. Evidence from positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Metter, E.J.; Hanson, W.R.; Jackson, C.A.; Kempler, D.; van Lancker, D.; Mazziotta, J.C.; Phelps, M.E. (National Institute of Aging, Baltimore, MD (USA))

    1990-11-01

    Forty-four aphasic patients were examined with (F18)-fluorodeoxyglucose positron emission tomography in a resting state to determine whether consistent glucose metabolic abnormalities were present. Ninety-seven percent of subjects showed metabolic abnormalities in the angular gyrus, 89% in the supramarginal gyrus, and 87% in the lateral and transverse superior temporal gyrus. Pearson product moment correlations were calculated between regional metabolic measures and performance on the Western Aphasia Battery. No significant correlations were found between the Western Aphasia Battery scores and right hemisphere metabolic measures. Most left hemisphere regions correlated with more than one score from the Western Aphasia Battery. Temporal but not frontal regions had significant correlations to the comprehension score. The left temporoparietal region was consistently affected in these subjects, suggesting that common features in the aphasias were caused by left temporoparietal dysfunction, while behavioral differences resulted from (1) the extent of temporoparietal changes, and (2) dysfunction elsewhere in the brain, particularly the left frontal and subcortical areas.

  5. Quality control of positron emission tomography radiopharmaceuticals: An institutional experience.

    Science.gov (United States)

    Shukla, Jaya; Vatsa, Rakhee; Garg, Nitasha; Bhusari, Priya; Watts, Ankit; Mittal, Bhagwant R

    2013-10-01

    To study quality control parameters of routinely prepared positron emission tomography (PET) radiopharmaceuticals. Three PET radiopharmaceuticals fluorine-18 fluorodeoxyglucose (F-18 FDG), N-13 ammonia (N-13 NH3), and Ga-68 DOTATATE (n = 25 each), prepared by standardized protocols were used. The radionuclide purity, radiochemical purity, residual solvents, pH, endotoxins, and sterility of these radiopharmaceuticals were determined. The physical half-life of radionuclide in radiopharmaceuticals, determined by both graphical and formula method, demonstrated purity of radionuclides used. pH of all PET radiopharmaceuticals used was in the range of 5-6.5. No microbial growth was observed in radiopharmaceutical preparations. The residual solvents, chemical impurity, and pyrogens were within the permissible limits. All three PET radiopharmaceuticals were safe for intravenous administration.

  6. Serotonin synthesis studied with positron emission tomography, (PET)

    DEFF Research Database (Denmark)

    Honoré, Per Gustaf Hartvig; Lundquist, Pinelopi

    Positron emission tomography (PET) has the potential to study the biosynthesis and release of serotonin (5HT) at brain serotonergic neurons. PET requires probe compounds with specific attributes to enable imaging and quantification of biological processes. This section focuses on probes to measure...... seroonin synthesis rate. Knowledge of altered 5HT synthesis and release in disease states may furnish basis for effective pharmacotherapy that may improve the care of psychiatric and neurological disease. Validation of PET measurements of the two PET tracers using perturbation showed that 5-hydroxy......-L-(beta-11C tryptophan) (5HTP) quantifies the activity of amino acid decarboxylase in the conversion to 5HT. On the other hand, alpha-methyl-tryptophan (AMT) measures the conversion to the corresponding 5-hydroxytryptophan analogue. The irreversible binding of the PET probe 5HTP in the monkey brain was lower...

  7. Studies of the brain cannabinoid system using positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Gatley, S.J.; Volkow, N.D.

    1995-10-01

    Studies using radiolabeled psychoactive drugs in conjunction with positron emission tomography (PET) have permitted the imaging of binding sites in the human brain. Similar studies of marijuana have been hampered by the unsuitability of radiolabeled THC for PET studies, and the current unavailability of other in vivo imaging agents for cannabinoid receptors. Recent developments in medicinal chemistry suggest that a PET radiotracer for cannabinoid receptors will soon become available. This chapter briefly reviews these developments, together with the results of PET studies of the effects of marijuana and other abused drugs on brain metabolism. It also reviews PET studies of cocaine binding sites, to demonstrate the kind of investigations that will be possible when a cannabinoid receptor PET radioligand becomes available.

  8. Positron Emission Tomography with Three-Dimensional Reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Erlandsson, K.

    1996-10-01

    The development of two different low-cost scanners for positron emission tomography (PET) based on 3D acquisition are presented. The first scanner consists of two rotating scintillation cameras, and produces quantitative images, which have shown to be clinically useful. The second one is a system with two opposed sets of detectors, based on the limited angle tomography principle, dedicated for mammographic studies. The development of low-cost PET scanners can increase the clinical impact of PET, which is an expensive modality, only available at a few centres world-wide and mainly used as a research tool. A 3D reconstruction method was developed that utilizes all the available data. The size of the data-sets is considerably reduced, using the single-slice rebinning approximation. The 3D reconstruction is divided into 1D axial deconvolution and 2D transaxial reconstruction, which makes it relatively fast. This method was developed for the rotating scanner, but was also implemented for multi-ring scanners with and without inter plane septa. An iterative 3D reconstruction method was developed for the limited angle scanner, based on the new concept of `mobile pixels`, which reduces the finite pixel errors and leads to an improved signal to noise ratio. 100 refs.

  9. Method of synthesizing small-diameter carbon nanotubes with electron field emission properties

    Science.gov (United States)

    Liu, Jie (Inventor); Du, Chunsheng (Inventor); Qian, Cheng (Inventor); Gao, Bo (Inventor); Qiu, Qi (Inventor); Zhou, Otto Z. (Inventor)

    2009-01-01

    Carbon nanotube material having an outer diameter less than 10 nm and a number of walls less than ten are disclosed. Also disclosed are an electron field emission device including a substrate, an optionally layer of adhesion-promoting layer, and a layer of electron field emission material. The electron field emission material includes a carbon nanotube having a number of concentric graphene shells per tube of from two to ten, an outer diameter from 2 to 8 nm, and a nanotube length greater than 0.1 microns. One method to fabricate carbon nanotubes includes the steps of (a) producing a catalyst containing Fe and Mo supported on MgO powder, (b) using a mixture of hydrogen and carbon containing gas as precursors, and (c) heating the catalyst to a temperature above 950.degree. C. to produce a carbon nanotube. Another method of fabricating an electron field emission cathode includes the steps of (a) synthesizing electron field emission materials containing carbon nanotubes with a number of concentric graphene shells per tube from two to ten, an outer diameter of from 2 to 8 nm, and a length greater than 0.1 microns, (b) dispersing the electron field emission material in a suitable solvent, (c) depositing the electron field emission materials onto a substrate, and (d) annealing the substrate.

  10. Use of Positron Emission Tomography/Computed Tomography in Radiation Treatment Planning for Lung Cancer

    Directory of Open Access Journals (Sweden)

    Kezban Berberoğlu

    2016-06-01

    Full Text Available Radiotherapy (RT plays an important role in the treatment of lung cancer. Accurate diagnosis and staging are crucial in the delivery of RT with curative intent. Target miss can be prevented by accurate determination of tumor contours during RT planning. Currently, tumor contours are determined manually by computed tomography (CT during RT planning. This method leads to differences in delineation of tumor volume between users. Given the change in RT tools and methods due to rapidly developing technology, it is now more significant to accurately delineate the tumor tissue. F18 fluorodeoxyglucose positron emission tomography/CT (F18 FDG PET/CT has been established as an accurate method in correctly staging and detecting tumor dissemination in lung cancer. Since it provides both anatomic and biologic information, F18 FDG PET decreases interuser variability in tumor delineation. For instance, tumor volumes may be decreased as atelectasis and malignant tissue can be more accurately differentiated, as well as better evaluation of benign and malignant lymph nodes given the difference in FDG uptake. Using F18 FDG PET/CT, the radiation dose can be escalated without serious adverse effects in lung cancer. In this study, we evaluated the contribution of F18 FDG PET/CT for RT planning in lung cancer.

  11. Small-Animal Imaging Using Clinical Positron Emission Tomography/Computed Tomography and Super-Resolution

    Directory of Open Access Journals (Sweden)

    Frank P. DiFilippo

    2012-05-01

    Full Text Available Considering the high cost of dedicated small-animal positron emission tomography/computed tomography (PET/CT, an acceptable alternative in many situations might be clinical PET/CT. However, spatial resolution and image quality are of concern. The utility of clinical PET/CT for small-animal research and image quality improvements from super-resolution (spatial subsampling were investigated. National Electrical Manufacturers Association (NEMA NU 4 phantom and mouse data were acquired with a clinical PET/CT scanner, as both conventional static and stepped scans. Static scans were reconstructed with and without point spread function (PSF modeling. Stepped images were postprocessed with iterative deconvolution to produce super-resolution images. Image quality was markedly improved using the super-resolution technique, avoiding certain artifacts produced by PSF modeling. The 2 mm rod of the NU 4 phantom was visualized with high contrast, and the major structures of the mouse were well resolved. Although not a perfect substitute for a state-of-the-art small-animal PET/CT scanner, a clinical PET/CT scanner with super-resolution produces acceptable small-animal image quality for many preclinical research studies.

  12. Positron emission tomography / computerized tomography evaluation of primary Hodgkin's disease of liver.

    Science.gov (United States)

    Gota, V S; Purandare, N C; Gujral, S; Shah, S; Nair, R; Rangarajan, V

    2009-01-01

    Occurrence of primary Hodgkin's lymphoma (PHL) of the liver is extremely rare. We report on a case of a 60-year-old male who presented with liver mass and B-symptomatology. Hepatoma or hepatic metastasis from a gastrointestinal primary was initially suspected. Tumor markers like AFP, CEA, Total PSA, and CA-19.9 were within normal limits. Positron Emission Tomography / Computerized Tomography (PET/CT) revealed a large hepatic lesion and a nodal mass in the porta hepatis. A liver biopsy was consistent with Hodgkin's lymphoma. There was complete regression of the hepatic lesion and evidence of shrinkage of the nodal mass following four cycles of chemotherapy. 18F Fluro -de-oxy Glucose (FDG) PET / CT in this case helped in establishing a primary hepatic lymphoma by demonstrating the absence of pathologically hypermetabolic foci in any other nodes or organs. PET / CT scan is a useful adjunct to conventional imaging and histopathology, not only to establish the initial diagnosis, but also to monitor treatment response in PHL.

  13. Positron emission tomography/computed tomography imaging features of renal cell carcinoma and pulmonary metastases in a dog.

    Science.gov (United States)

    Song, Sun-Hye; Park, Noh-Won; Eom, Ki-Dong

    2014-05-01

    A 9-year-old spayed female cocker spaniel dog was referred for hematuria. A large abdominal mass and multiple pulmonary nodules were identified radiographically. A whole-body 2-deoxy-2-[(18)F]fluoro-d-glucose positron emission tomography/computed tomography (PET/CT) scan revealed intensely increased uptake in a renal mass and the pulmonary nodules. Renal cell carcinoma was diagnosed on histological examination.

  14. Positron emission tomography/computed tomography imaging features of renal cell carcinoma and pulmonary metastases in a dog

    OpenAIRE

    Song, Sun-Hye; Park, Noh-Won; Eom, Ki-Dong

    2014-01-01

    A 9-year-old spayed female cocker spaniel dog was referred for hematuria. A large abdominal mass and multiple pulmonary nodules were identified radiographically. A whole-body 2-deoxy-2-[18F]fluoro-d-glucose positron emission tomography/computed tomography (PET/CT) scan revealed intensely increased uptake in a renal mass and the pulmonary nodules. Renal cell carcinoma was diagnosed on histological examination.

  15. Primary Retroperitoneal Seminoma Staging and Surveillance by Means of Fluoro-2-Deoxyglucose-Positron Emission Tomography/Computed Tomography.

    Science.gov (United States)

    Liu, Tianye; Aparici, Carina Mari

    2015-01-01

    Primary retroperitoneal seminoma is a very rare entity. We present a case of 39-year-old male with primary retroperitoneal seminoma with staging and surveillance by means of F-18 fluoro-2-deoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT). The case demonstrates that primary retroperitoneal seminoma can be easy to identify with FDG-PET/CT and potential follow-up on recurrence, or metastatic disease can be performed using this technique.

  16. Impact of F-18-fluorodeoxyglucose positron emission tomography/computed tomography staging in newly diagnosed classical Hodgkin lymphoma

    DEFF Research Database (Denmark)

    El-Galaly, T. C.; Hutchings, M.; Juul Mylam, Karen

    2014-01-01

    F-18-Fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) is a highly accurate staging method in classical Hodgkin lymphoma (cHL). We retrospectively compared the staging results obtained in two large cohorts of patients with cHL diagnosed before (n = 324) and after (n = 406......%, p Hodgkin Study Group (GHSG) risk classification (early, intermediate, advanced disease) predicted outcome in PET...

  17. Radiolabelling diverse positron emission tomography (PET) tracers using a single digital microfluidic reactor chip.

    Science.gov (United States)

    Chen, Supin; Javed, Muhammad Rashed; Kim, Hee-Kwon; Lei, Jack; Lazari, Mark; Shah, Gaurav J; van Dam, R Michael; Keng, Pei-Yuin; Kim, Chang-Jin C J

    2014-03-07

    Radiotracer synthesis is an ideal application for microfluidics because only nanogram quantities are needed for positron emission tomography (PET) imaging. Thousands of radiotracers have been developed in research settings but only a few are readily available, severely limiting the biological problems that can be studied in vivo via PET. We report the development of an electrowetting-on-dielectric (EWOD) digital microfluidic chip that can synthesize a variety of (18)F-labeled tracers targeting a range of biological processes by confirming complete syntheses of four radiotracers: a sugar, a DNA nucleoside, a protein labelling compound, and a neurotransmitter. The chip employs concentric multifunctional electrodes that are used for heating, temperature sensing, and EWOD actuation. All of the key synthesis steps for each of the four (18)F-labeled tracers are demonstrated and characterized with the chip: concentration of fluoride ion, solvent exchange, and chemical reactions. The obtained fluorination efficiencies of 90-95% are comparable to, or greater than, those achieved by conventional approaches.

  18. European health telematics networks for positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kontaxakis, George [Universidad Politecnica de Madrid, ETSI Telecomunicacion, Madrid 28040 (Spain)]. E-mail: g.kontaxakis@upm.es; Pozo, Miguel Angel [Centro PET Complutense, Madrid 28040 (Spain); Universidad Complutense de Madrid, Instituto Pluridisciplinar, Madrid 28040 (Spain); Ohl, Roland [MedCom Gesellschaft fuer medizinische Bildverarbeitung mbH, Darmstadt 64283 (Germany); Visvikis, Dimitris [U650 INSERM, Lab. du Traitement de L' Information Medicale, University of Brest Occidentale, CHU Morvan, Brest 29609 (France); Sachpazidis, Ilias [Fraunhofer Institute for Computer Graphics, Darmstadt 64283 (Germany); Ortega, Fernando [Fundacion Instituto Valenciano de Oncologia, Valencia 46009 (Spain); Guerra, Pedro [Universidad Politecnica de Madrid, ETSI Telecomunicacion, Madrid 28040 (Spain); Cheze-Le Rest, Catherine [Dept. Medicine Nucleaire, CHU Morvan, Brest 29609 (France); Selby, Peter [MedCom Gesellschaft fuer medizinische Bildverarbeitung mbH, Darmstadt 64283 (Germany); Pan, Leyun [German Cancer Research Centre, Clinical Cooperation Unit Nuclear Medicine, Heidelberg 69120 (Germany); Diaz, Javier [Fundacion Instituto Valenciano de Oncologia, Valencia 46009 (Spain); Dimitrakopoulou-Strauss, Antonia [German Cancer Research Centre, Clinical Cooperation Unit Nuclear Medicine, Heidelberg 69120 (Germany); Santos, Andres [Universidad Politecnica de Madrid, ETSI Telecomunicacion, Madrid 28040 (Spain); Strauss, Ludwig [German Cancer Research Centre, Clinical Cooperation Unit Nuclear Medicine, Heidelberg 69120 (Germany); Sakas, Georgios [MedCom Gesellschaft fuer medizinische Bildverarbeitung mbH, Darmstadt 64283 (Germany); Fraunhofer Institute for Computer Graphics, Darmstadt 64283 (Germany)

    2006-12-20

    A pilot network of positron emission tomography centers across Europe has been setup employing telemedicine services. The primary aim is to bring all PET centers in Europe (and beyond) closer, by integrating advanced medical imaging technology and health telematics networks applications into a single, easy to operate health telematics platform, which allows secure transmission of medical data via a variety of telecommunications channels and fosters the cooperation between professionals in the field. The platform runs on PCs with Windows 2000/XP and incorporates advanced techniques for image visualization, analysis and fusion. The communication between two connected workstations is based on a TCP/IP connection secured by secure socket layers and virtual private network or jabber protocols. A teleconsultation can be online (with both physicians physically present) or offline (via transmission of messages which contain image data and other information). An interface sharing protocol enables online teleconsultations even over low bandwidth connections. This initiative promotes the cooperation and improved communication between nuclear medicine professionals, offering options for second opinion and training. It permits physicians to remotely consult patient data, even if they are away from the physical examination site.

  19. Simultaneous laser speckle imaging and positron emission tomography

    Science.gov (United States)

    Gramer, M.; Feuerstein, D.; Backes, H.; Takagaki, M.; Kumagai, T.; Graf, R.

    2013-06-01

    Complex biological systems often require measurements of multiple parameters with high temporal and spatial resolution. Multimodal approaches and the combination of methods are therefore a powerful tool to address such scientific questions. Laser speckle imaging (LSI) is an optical method that monitors dynamic changes in cortical blood flow (CBF) with high temporal resolution. Positron emission tomography (PET) allows for quantitative imaging of physiological processes and is a gold standard method to determine absolute cerebral blood flow. We developed a setup that allows simultaneous measurement with both modalities. Here, we simultaneously measured CBF with PET and LSI in rats and analyzed how the correlation of PET and LSI is modified when (1) different methods are used for the calculation of speckle inverse correlation time (ICT), (2) speckle data is acquired through thinned or craniectomized skull, (3) influence of surface vessels is removed from the speckle data. For the latter, a method for automated vessel segmentation from LSI data was developed. We obtained the best correlation (R² = 0.890, pICT. Thus, LSI provides CBF in absolute units at high temporal resolution.

  20. Effect of attenuation correction on image quality in emission tomography

    Science.gov (United States)

    Denisova, N. V.; Ondar, M. M.

    2017-10-01

    In this paper, mathematical modeling and computer simulations of myocardial perfusion SPECT imaging are performed. The main factors affecting the quality of reconstructed images in SPECT are anatomical structures, the diastolic volume of a myocardium and attenuation of gamma rays. The purpose of the present work is to study the effect of attenuation correction on image quality in emission tomography. The basic 2D model describing a Tc-99m distribution in a transaxial slice of the thoracic part of a patient body was designed. This model was used to construct four phantoms simulated various anatomical shapes: 2 male and 2 female patients with normal, obese and subtle physique were included in the study. Data acquisition model which includes the effect of non-uniform attenuation, collimator-detector response and Poisson statistics was developed. The projection data were calculated for 60 views in accordance with the standard myocardial perfusion SPECT imaging protocol. Reconstructions of images were performed using the OSEM algorithm which is widely used in modern SPECT systems. Two types of patient's examination procedures were simulated: SPECT without attenuation correction and SPECT/CT with attenuation correction. The obtained results indicate a significant effect of the attenuation correction on the SPECT images quality.

  1. Characterization of time resolved photodetector systems for Positron Emission Tomography

    CERN Document Server

    Powolny, François

    The main topic of this work is the study of detector systems composed of a scintillator, a photodetector and readout electronics, for Positron Emission Tomography (PET). In particular, the timing properties of such detector systems are studied. The first idea is to take advantage of the good timing properties of the NINO chip, which is a fast preamplifier-discriminator developed for the ALICE Time of flight detector at CERN. This chip uses a time over threshold technique that is to be applied for the first time in medical imaging applications. A unique feature of this technique is that it delivers both timing and energy information with a single digital pulse, the time stamp with the rising edge and the energy from the pulse width. This entails substantial simplification of the entire readout architecture of a tomograph. The scintillator chosen in the detector system is LSO. Crystals of 2x2x10mm3 were used. For the photodetector, APDs were first used, and were then replaced by SiPMs to make use of their highe...

  2. European health telematics networks for positron emission tomography

    Science.gov (United States)

    Kontaxakis, George; Pozo, Miguel Angel; Ohl, Roland; Visvikis, Dimitris; Sachpazidis, Ilias; Ortega, Fernando; Guerra, Pedro; Cheze-Le Rest, Catherine; Selby, Peter; Pan, Leyun; Diaz, Javier; Dimitrakopoulou-Strauss, Antonia; Santos, Andres; Strauss, Ludwig; Sakas, Georgios

    2006-12-01

    A pilot network of positron emission tomography centers across Europe has been setup employing telemedicine services. The primary aim is to bring all PET centers in Europe (and beyond) closer, by integrating advanced medical imaging technology and health telematics networks applications into a single, easy to operate health telematics platform, which allows secure transmission of medical data via a variety of telecommunications channels and fosters the cooperation between professionals in the field. The platform runs on PCs with Windows 2000/XP and incorporates advanced techniques for image visualization, analysis and fusion. The communication between two connected workstations is based on a TCP/IP connection secured by secure socket layers and virtual private network or jabber protocols. A teleconsultation can be online (with both physicians physically present) or offline (via transmission of messages which contain image data and other information). An interface sharing protocol enables online teleconsultations even over low bandwidth connections. This initiative promotes the cooperation and improved communication between nuclear medicine professionals, offering options for second opinion and training. It permits physicians to remotely consult patient data, even if they are away from the physical examination site.

  3. Quantitative Cardiac Positron Emission Tomography: The Time Is Coming!

    Directory of Open Access Journals (Sweden)

    Roberto Sciagrà

    2012-01-01

    Full Text Available In the last 20 years, the use of positron emission tomography (PET has grown dramatically because of its oncological applications, and PET facilities are now easily accessible. At the same time, various groups have explored the specific advantages of PET in heart disease and demonstrated the major diagnostic and prognostic role of quantitation in cardiac PET. Nowadays, different approaches for the measurement of myocardial blood flow (MBF have been developed and implemented in user-friendly programs. There is large evidence that MBF at rest and under stress together with the calculation of coronary flow reserve are able to improve the detection and prognostication of coronary artery disease. Moreover, quantitative PET makes possible to assess the presence of microvascular dysfunction, which is involved in various cardiac diseases, including the early stages of coronary atherosclerosis, hypertrophic and dilated cardiomyopathy, and hypertensive heart disease. Therefore, it is probably time to consider the routine use of quantitative cardiac PET and to work for defining its place in the clinical scenario of modern cardiology.

  4. Brain single photon emission computed tomography in neonates

    Energy Technology Data Exchange (ETDEWEB)

    Denays, R.; Van Pachterbeke, T.; Tondeur, M.; Spehl, M.; Toppet, V.; Ham, H.; Piepsz, A.; Rubinstein, M.; Nol, P.H.; Haumont, D. (Free Universities of Brussels (Belgium))

    1989-08-01

    This study was designed to rate the clinical value of ({sup 123}I)iodoamphetamine (IMP) or ({sup 99m}Tc) hexamethyl propylene amine oxyme (HM-PAO) brain single photon emission computed tomography (SPECT) in neonates, especially in those likely to develop cerebral palsy. The results showed that SPECT abnormalities were congruent in most cases with structural lesions demonstrated by ultrasonography. However, mild bilateral ventricular dilatation and bilateral subependymal porencephalic cysts diagnosed by ultrasound were not associated with an abnormal SPECT finding. In contrast, some cortical periventricular and sylvian lesions and all the parasagittal lesions well visualized in SPECT studies were not diagnosed by ultrasound scans. In neonates with subependymal and/or intraventricular hemorrhage the existence of a parenchymal abnormality was only diagnosed by SPECT. These results indicate that ({sup 123}I)IMP or ({sup 99m}Tc)HM-PAO brain SPECT shows a potential clinical value as the neurodevelopmental outcome is clearly related to the site, the extent, and the number of cerebral lesions. Long-term clinical follow-up is, however, mandatory in order to define which SPECT abnormality is associated with neurologic deficit.

  5. Silicon as an unconventional detector in positron emission tomography

    Science.gov (United States)

    Clinthorne, Neal; Brzezinski, Karol; Chesi, Enrico; Cochran, Eric; Grkovski, Milan; Grošičar, Borut; Honscheid, Klaus; Huh, Sam; Kagan, Harris; Lacasta, Carlos; Linhart, Vladimir; Mikuž, Marko; Smith, D. Shane; Stankova, Vera; Studen, Andrej; Weilhammer, Peter; Žontar, Dejan

    2013-01-01

    Positron emission tomography (PET) is a widely used technique in medical imaging and in studying small animal models of human disease. In the conventional approach, the 511 keV annihilation photons emitted from a patient or small animal are detected by a ring of scintillators such as LYSO read out by arrays of photodetectors. Although this has been successful in achieving ˜5 mm FWHM spatial resolution in human studies and ˜1 mm resolution in dedicated small animal instruments, there is interest in significantly improving these figures. Silicon, although its stopping power is modest for 511 keV photons, offers a number of potential advantages over more conventional approaches including the potential for high intrinsic spatial resolution in 3D. To evaluate silicon in a variety of PET "magnifying glass" configurations, an instrument was constructed that consists of an outer partial-ring of PET scintillation detectors into which various arrangements of silicon detectors are inserted to emulate dual-ring or imaging probe geometries. Measurements using the test instrument demonstrated the capability of clearly resolving point sources of 22Na having a 1.5 mm center-to-center spacing as well as the 1.2 mm rods of a 18F-filled resolution phantom. Although many challenges remain, silicon has potential to become the PET detector of choice when spatial resolution is the primary consideration.

  6. Quantifying the limitations of small animal positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Oxley, D.C. [Department of Physics, University of Liverpool, Liverpool L69 7ZE (United Kingdom)], E-mail: dco@ns.ph.liv.ac.uk; Boston, A.J.; Boston, H.C.; Cooper, R.J.; Cresswell, J.R.; Grint, A.N.; Nolan, P.J.; Scraggs, D.P. [Department of Physics, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Lazarus, I.H. [STFC Daresbury Laboratory, Warrington, WA4 4AD Cheshire (United Kingdom); Beveridge, T.E. [School of Materials and Engineering, Monash University, Melbourne (Australia)

    2009-06-01

    The application of position sensitive semiconductor detectors in medical imaging is a field of global research interest. The Monte-Carlo simulation toolkit GEANT4 [ (http://geant4.web.cern.ch/geant4/)] was employed to improve the understanding of detailed {gamma}-ray interactions within the small animal Positron Emission Tomography (PET), high-purity germanium (HPGe) imaging system, SmartPET [A.J. Boston, et al., Oral contribution, ANL, Chicago, USA, 2006]. This system has shown promising results in the field of PET [R.J. Cooper, et al., Nucl. Instr. and Meth. A (2009), accepted for publication] and Compton camera imaging [J.E. Gillam, et al., Nucl. Instr. and Meth. A 579 (2007) 76]. Images for a selection of single and multiple point, line and phantom sources were successfully reconstructed using both a filtered-back-projection (FBP) [A.R. Mather, Ph.D. Thesis, University of Liverpool, 2007] and an iterative reconstruction algorithm [A.R. Mather, Ph.D. Thesis, University of Liverpool, 2007]. Simulated data were exploited as an alternative route to a reconstructed image allowing full quantification of the image distortions introduced in each phase of the data processing. Quantifying the contribution of uncertainty in all system components from detector to reconstruction algorithm allows the areas in need of most attention on the SmartPET project and semiconductor PET to be addressed.

  7. Simultaneous in vivo positron emission tomography and magnetic resonance imaging.

    Science.gov (United States)

    Catana, Ciprian; Procissi, Daniel; Wu, Yibao; Judenhofer, Martin S; Qi, Jinyi; Pichler, Bernd J; Jacobs, Russell E; Cherry, Simon R

    2008-03-11

    Positron emission tomography (PET) and magnetic resonance imaging (MRI) are widely used in vivo imaging technologies with both clinical and biomedical research applications. The strengths of MRI include high-resolution, high-contrast morphologic imaging of soft tissues; the ability to image physiologic parameters such as diffusion and changes in oxygenation level resulting from neuronal stimulation; and the measurement of metabolites using chemical shift imaging. PET images the distribution of biologically targeted radiotracers with high sensitivity, but images generally lack anatomic context and are of lower spatial resolution. Integration of these technologies permits the acquisition of temporally correlated data showing the distribution of PET radiotracers and MRI contrast agents or MR-detectable metabolites, with registration to the underlying anatomy. An MRI-compatible PET scanner has been built for biomedical research applications that allows data from both modalities to be acquired simultaneously. Experiments demonstrate no effect of the MRI system on the spatial resolution of the PET system and PET scanner inside the MRI. The signal-to-noise ratio and uniformity of the MR images, with the exception of one particular pulse sequence, were little affected by the presence of the PET scanner. In vivo simultaneous PET and MRI studies were performed in mice. Proof-of-principle in vivo MR spectroscopy and functional MRI experiments were also demonstrated with the combined scanner.

  8. Epithelioid sarcoma with muscle metastasis detected by positron emission tomography

    Directory of Open Access Journals (Sweden)

    Oya Masafumi

    2008-08-01

    Full Text Available Abstract Background Epithelioid sarcoma is an uncommon high-grade sarcoma, mostly involving the extremities. Case presentation A 33-year-old man was referred to our institute with a diagnosis of Volkmann's contracture with the symptom of flexion contracture of the fingers associated with swelling in his left forearm. Magnetic resonance imaging (MRI showed abnormal signal intensity, comprising iso-signal intensity on T1- and high-signal intensity on T2-weighted images surrounding the flexor tendons in the forearm. Diagnosis of epithelioid sarcoma was made by open biopsy, and amputation at the upper arm was then undertaken. [18F]-2-fluoro-2-deoxy-D-glucose-positron emission tomography (FDG-PET detected multiple lesions with an increased uptake in the right neck, the bilateral upper arms and the right thigh, as well as in the left axillary lymph nodes, with maximum standardized uptake value (SUVmax ranging from 2.0 to 5.5 g/ml. Magnetic resonance imaging confirmed that there was a lesion within the right thigh muscle which was suggestive of metastasis, even though the lesion was occult clinically. Conclusion Increased uptake on FDG-PET might be representative of epithelioid sarcoma, and for this reason FDG-PET may be useful for detecting metastasis. Muscle metastasis is not well documented in epithelioid sarcoma. Accordingly, the frequency of muscle metastasis, including occult metastasis, needs to be further analyzed.

  9. Quantifying the limitations of small animal positron emission tomography

    Science.gov (United States)

    Oxley, D. C.; Boston, A. J.; Boston, H. C.; Cooper, R. J.; Cresswell, J. R.; Grint, A. N.; Nolan, P. J.; Scraggs, D. P.; Lazarus, I. H.; Beveridge, T. E.

    2009-06-01

    The application of position sensitive semiconductor detectors in medical imaging is a field of global research interest. The Monte-Carlo simulation toolkit GEANT4 [ http://geant4.web.cern.ch/geant4/] was employed to improve the understanding of detailed γ-ray interactions within the small animal Positron Emission Tomography (PET), high-purity germanium (HPGe) imaging system, SmartPET [A.J. Boston, et al., Oral contribution, ANL, Chicago, USA, 2006]. This system has shown promising results in the field of PET [R.J. Cooper, et al., Nucl. Instr. and Meth. A (2009), accepted for publication] and Compton camera imaging [J.E. Gillam, et al., Nucl. Instr. and Meth. A 579 (2007) 76]. Images for a selection of single and multiple point, line and phantom sources were successfully reconstructed using both a filtered-back-projection (FBP) [A.R. Mather, Ph.D. Thesis, University of Liverpool, 2007] and an iterative reconstruction algorithm [A.R. Mather, Ph.D. Thesis, University of Liverpool, 2007]. Simulated data were exploited as an alternative route to a reconstructed image allowing full quantification of the image distortions introduced in each phase of the data processing. Quantifying the contribution of uncertainty in all system components from detector to reconstruction algorithm allows the areas in need of most attention on the SmartPET project and semiconductor PET to be addressed.

  10. Trends in radiation protection of positron emission tomography/computed tomography imaging.

    Science.gov (United States)

    Alenezi, A; Soliman, K

    2015-06-01

    Over the past decade, the number of positron emission tomography/computed tomography (PET/CT) imaging procedures has increased substantially. This imaging technique provides accurate functional and anatomical information, particularly for oncological applications. Separately, both PET and CT are considered as high-dose imaging modalities. With the increased use of PET/CT, one could expect an increase in radiation doses to staff and patients. As such, major efforts have been made to reduce radiation dose in PET/CT facilities. Variations in working techniques have made it difficult to compare published results. This study aimed to review the literature on proposed methods to reduce patient and staff dose in clinical PET/CT imaging. A brief overview of some published information on staff and patient doses will be analysed and presented. Recent trends regarding radiation protection in PET/CT imaging will be discussed, and practical recommendations for reducing radiation doses to staff and patients will be discussed and summarised. Generally, the CT dose component is often higher in magnitude than the dose from PET alone; as such, focusing on CT dose reduction will decrease the overall patient dose in PET/CT imaging studies. The following factors should be considered in order to reduce the patient's dose from CT alone: proper justification for ordering contrast-enhanced CT; use of automatic exposure control features; use of adaptive statistical iterative reconstruction algorithms; and optimisation of scan parameters, especially scan length. The PET dose component can be reduced by administration of lower activity to the patient, optimisation of the workflow, and appropriate use of protective devices and engineered systems. At the international level, there is wide variation in work practices among institutions. The current observed trends are such that the annual dose limits for radiation workers in PET/CT imaging are unlikely to be exceeded. © Author(s) 2014.

  11. F18-fluorodeoxyglucose-positron emission tomography/computed tomography screening in Li-Fraumeni syndrome.

    Science.gov (United States)

    Masciari, Serena; Van den Abbeele, Annick D; Diller, Lisa R; Rastarhuyeva, Iryna; Yap, Jeffrey; Schneider, Katherine; Digianni, Lisa; Li, Frederick P; Fraumeni, Joseph F; Syngal, Sapna; Garber, Judy E

    2008-03-19

    Individuals with Li-Fraumeni syndrome (LFS) have an inherited cancer predisposition to a diverse array of malignancies beginning early in life; survivors of one cancer have a markedly elevated risk of additional primary tumors. The underlying genetic defect in the majority of the families is a germline mutation in the TP53 tumor suppressor gene. The diversity of tumors and rarity of families have contributed to the difficulty in devising effective screening recommendations for members of LFS kindreds. To gather preliminary data with which to evaluate F18-fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) imaging as a potential surveillance modality to detect early malignancies in asymptomatic members of LFS kindreds. Members of LFS families with documented germline TP53 mutations or obligate carrier status, no history of cancer within 5 years of enrollment, and no symptoms of cancer or ill-health were offered FDG-PET/CT scanning as a screening test in a comprehensive US cancer center from 2006 to 2007. Scans were initially reviewed clinically, then centrally reviewed by an expert radiologist. The primary outcome was the detection of new primary cancers using FDG-PET/CT scanning. Of 15 individuals, baseline FDG-PET/CT scan identified asymptomatic cancers in 3 (20%). Two individuals had papillary thyroid cancers (stage II and stage III) and one individual had stage II esophageal adenocarcinoma. These preliminary data provide the first evidence for a potential cancer surveillance strategy that may be worthy of further investigation for patients with LFS. Concerns about radiation exposure and other challenges inherent in screening high-risk patients will require further consideration.

  12. Whole-body magnetic resonance imaging and positron emission tomography-computed tomography in oncology.

    Science.gov (United States)

    Schmidt, Gerwin P; Kramer, Harald; Reiser, Maximilian F; Glaser, Christian

    2007-06-01

    The advent of positron emission tomography-computed tomography (PET-CT) and whole-body magnetic resonance imaging (WB-MRI) has introduced tumor imaging with a systemic and functional approach compared with established sequential, multimodal diagnostic algorithms.Whole-body PET with [18F]-fluoro-2-desoxy-glucose is a useful imaging procedure for tumor staging and monitoring that can visualize active tumor tissue by detecting pathological glucose metabolism. The combination of PET with the detailed anatomical information of multislice computed tomography as dual-modality scanners has markedly increased lesion localization and diagnostic accuracy compared with both modalities as standalone applications.Hardware innovations, such as the introduction of multi-receiver channel whole-body MRI scanners at 1.5 and, recently, 3 T, combined with acquisition acceleration techniques, have made high-resolution WB-MRI clinically feasible. Now, a dedicated assessment of individual organs with various soft tissue contrast, spatial resolution, and contrast media dynamics can be combined with whole-body anatomical coverage in a multiplanar imaging approach. More flexible protocols (eg, T1-weighted turbo spin-echo and short inversion recovery imaging, dedicated lung imaging or dynamic contrast-enhanced studies of the abdomen) can be performed within 45 minutes.Whole-body magnetic resonance imaging has recently been proposed for tumor screening of asymptomatic individuals, and potentially life-changing diagnoses, such as formerly unknown malignancy, have been reported. However, larger patient cohort studies will have to show the cost efficiency and the clinical effectiveness of such an approach.For initial tumor staging, PET-CT has proved more accurate for the definition of T-stage and lymph node assessment, mainly because of the missing metabolic information in WB-MRI. However, new applications, such as magnetic resonance whole-body diffusion-weighted imaging or lymphotropic contrast

  13. Central benzodiazepine receptor imaging and quantitation with single photon emission computerised tomography

    DEFF Research Database (Denmark)

    Okocha, C I; Kapczinski, F; Lassen, N

    1995-01-01

    This review discusses the current use of single photon emission computerised tomography (SPECT) for central benzodiazepine receptor imaging and quantitation. The general principles underlying SPECT imaging and receptor quantitation methods such as the kinetic, pseudo-equilibrium and steady...

  14. Imaging Atherosclerosis with Hybrid Positron Emission Tomography/Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Ripa, Rasmus Sejersten; Kjær, Andreas

    2015-01-01

    Noninvasive imaging of atherosclerosis could potentially move patient management towards individualized triage, treatment, and followup. The newly introduced combined positron emission tomography (PET) and magnetic resonance imaging (MRI) system could emerge as a key player in this context. Both ...

  15. Estimation of intersubject variability of cerebral blood flow measurements using MRI and positron emission tomography

    DEFF Research Database (Denmark)

    Henriksen, Otto Mølby; Larsson, Henrik B W; Hansen, Adam E

    2012-01-01

    PURPOSE: To investigate the within and between subject variability of quantitative cerebral blood flow (CBF) measurements in normal subjects using various MRI techniques and positron emission tomography (PET). MATERIALS AND METHODS: Repeated CBF measurements were performed in 17 healthy, young...

  16. Readout of scintillator light with avalanche photodiodes for positron emission tomography

    CERN Document Server

    Chen, R; Tavernier, Stefaan; Bruyndonckx, P; Clément, D; Loude, J F; Morel, Christian

    1999-01-01

    The noise properties and other relevant characteristics of avalanche photodiodes have been investigated with the perspective of replacing photomultiplier tubes in positron emission tomography. It is clearly demonstrated that they are a valid alternative to photomultiplier tubes in this application.

  17. Positron emission tomography for serial imaging of the contused adult rat spinal cord.

    NARCIS (Netherlands)

    Nandoe, R.D.S.; Yu, J.; Seidel, J.; Rahiem, S.T.; Hurtado, A.; Tsui, B.M.; Grotenhuis, J.A.; Pomper, M.G.; Oudega, M.

    2010-01-01

    We investigated whether small-animal positron emission tomography (PET) could be used in combination with computed tomography (CT) imaging techniques for longitudinal monitoring of the injured spinal cord. In adult female Sprague-Dawley rats (n = 6), the ninth thoracic (T9) spinal cord segment was

  18. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography

    DEFF Research Database (Denmark)

    Rochitte, Carlos E; George, Richard T; Chen, Marcus Y

    2014-01-01

    AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed ...

  19. Positron emission tomography: Which indications, which benefits?; Tomographie par emission de positons (TEP): quelles indications, quels benefices?

    Energy Technology Data Exchange (ETDEWEB)

    Chassoux, F. [Ctr Hosp St Anne, Serv Neurochirurg, F-75014 Paris (France); Chassoux, F.; Chiron, C. [CEA, I2BM, Serv Hosp Frederic Joliot, F-91 Orsay (France); Chiron, C. [Hop Necker Enfants Malad, INSERM, U663, F-75015 Paris (France); Chassoux, F.; Chiron, C. [Univ Paris 06, F-75005 Paris (France)

    2008-07-01

    Positron emission tomography (PET) is currently used in the pre-surgical workup for drug-resistant partial epilepsies in addition to MRI. Inter-ictal metabolism is studied in clinical practice using {sup 18}fluoro-desoxy-glucose ({sup 18}FDG). In medial temporal lobe epilepsy (MTLE) associated with hippocampal sclerosis, hypo-metabolism ipsilateral to the epileptogenic focus is found in 70-90% of cases. However, hypo-metabolism is larger than the structural lesion observed on MRI and includes the epileptogenic zone and ictal discharge spread areas. Hypo-metabolism is related to surgical outcome and cognitive disturbances in MTLE. Although the usefulness of PET appears less well-established in extra-temporal lobe epilepsy and in children, its sensitivity may be improved by co-registration and superimposition of PET on MRI at any age. Focal hypo-metabolism can be easily detected by visual analysis, allowing detection of minor gyral abnormalities that may correspond to focal cortical dysplasias. Moreover, in cases of negative MRI, focal hypo-metabolism findings may help invasive monitoring planning and deep electrode placement for SEEG, and finally improve surgical outcome. (authors)

  20. Physiologic positron emission tomography/CT imaging of an integrated orbital implant.

    Science.gov (United States)

    Graue, Gerardo F; Finger, Paul T

    2012-01-01

    A 46-year-old woman with a T4N0M0 choroidal melanoma was staged for metastatic disease with whole-body positron emission tomography/CT imaging. She underwent enucleation of the right eye and placement of a 20-mm MEDPOR spherical implant. Four months after surgery, follow-up positron emission tomography/CT imaging revealed physiologic metabolic activity in the MEDPOR implant with no evidence of orbital melanoma or chronic inflammation.

  1. Myocardial perfusion single photon emission computed tomography in asymptomatic diabetics.

    Science.gov (United States)

    Harshad, K; Sathyamurthy, I; Ashish, G; Padma, D; Shelley, S; Indirani, M; Subramanian, K

    2010-01-01

    Coronary artery disease (CAD) is the most important cause of mortality in diabetic patients. Diabetes mellitus (DM) due to autonomic neuropathy leads to asymptomatic CAD. Hence, it is important to screen the patients with DM for CAD. To study the prevalence of asymptomatic CAD by Myocardial Perfuision SPECT (Single Photon Emission Computed Tomography) (MPS) in diabetics. This prospective study included 88 asymptomatic patients (58 males and 30 females) of Type 2 DM of more than 5 years duration in the age group of 40-65 years. Risk factors like hypertension, dyslipidemia, smoking, family history of CAD and Body Mass Index > or = 25 kg/sq.m were assessed. All these patients underwent MPS study as two day standard protocol. Thirty eight patients underwent invasive Coronary Angiography (CAG) and stenosis greater than 50% was considered significant. Abnormal perfusion was detected in 38 (43%) diabetics and 4 (11%) controls. A total of 81 perfusion defects were identified (19 fired and 62 reversible). CAG showed significant coronary stenosis in 26 (68.4%), insignificant in 8 (21%) and no stenosis in 4 (10.6%) patients. A total of 114 coronaries were analysed, significant stenosis in 67 (58.8%) coronaries, 21 (18.4%) had insignificant lesions and 26(22.8%) were normal. In comparison to CAG, MPS had sensitivity of 86.6% and specificity of 51%. The Myocardial Perfusion SPECT is a sensitive diagnostic tool to identify ischemia in asymptomatic diabetics. MPS can be used as screening test for risk stratification. It has a prognostic value in predicting the outcome of CAD and can be useful for long-term follow up too.

  2. Alcohol ADME in primates studied with positron emission tomography.

    Directory of Open Access Journals (Sweden)

    Zizhong Li

    Full Text Available The sensitivity to the intoxicating effects of alcohol as well as its adverse medical consequences differ markedly among individuals, which reflects in part differences in alcohol's absorption, distribution, metabolism, and elimination (ADME properties. The ADME of alcohol in the body and its relationship with alcohol's brain bioavailability, however, is not well understood.The ADME of C-11 labeled alcohol, CH(3 (11CH(2OH, 1 and C-11 and deuterium dual labeled alcohol, CH(3 (11CD(2OH, 2 in baboons was compared based on the principle that C-D bond is stronger than C-H bond, thus the reaction is slower if C-D bond breaking occurs in a rate-determining metabolic step. The following ADME parameters in peripheral organs and brain were derived from time activity curve (TAC of positron emission tomography (PET scans: peak uptake (C(max; peak uptake time (T(max, half-life of peak uptake (T(1/2, the area under the curve (AUC(60 min, and the residue uptake (C(60 min.For 1 the highest uptake occurred in the kidney whereas for 2 it occurred in the liver. A deuterium isotope effect was observed in the kidneys in both animals studied and in the liver of one animal but not the other. The highest uptake for 1 and 2 in the brain was in striatum and cerebellum but 2 had higher uptake than 1 in all brain regions most evidently in thalamus and cingulate. Alcohol's brain uptake was significantly higher when given intravenously than when given orally and also when the animal was pretreated with a pharmacological dose of alcohol.The study shows that alcohol metabolism in peripheral organs had a large effect on alcohol's brain bioavailability. This study sets the stage for clinical investigation on how genetics, gender and alcohol abuse affect alcohol's ADME and its relationship to intoxication and medical consequences.

  3. Nonhuman Primate Positron Emission Tomography Neuroimaging in Drug Abuse Research

    Science.gov (United States)

    Murnane, Kevin Sean

    2011-01-01

    Positron emission tomography (PET) neuroimaging in nonhuman primates has led to significant advances in our current understanding of the neurobiology and treatment of stimulant addiction in humans. PET neuroimaging has defined the in vivo biodistribution and pharmacokinetics of abused drugs and related these findings to the time course of behavioral effects associated with their addictive properties. With novel radiotracers and enhanced resolution, PET neuroimaging techniques have also characterized in vivo drug interactions with specific protein targets in the brain, including neurotransmitter receptors and transporters. In vivo determinations of cerebral blood flow and metabolism have localized brain circuits implicated in the effects of abused drugs and drug-associated stimuli. Moreover, determinations of the predisposing factors to chronic drug use and long-term neurobiological consequences of chronic drug use, such as potential neurotoxicity, have led to novel insights regarding the pathology and treatment of drug addiction. However, similar approaches clearly need to be extended to drug classes other than stimulants. Although dopaminergic systems have been extensively studied, other neurotransmitter systems known to play a critical role in the pharmacological effects of abused drugs have been largely ignored in nonhuman primate PET neuroimaging. Finally, the study of brain activation with PET neuroimaging has been replaced in humans mostly by functional magnetic resonance imaging (fMRI). There has been some success in implementing pharmacological fMRI in awake nonhuman primates. Nevertheless, the unique versatility of PET imaging will continue to complement the systems-level strengths of fMRI, especially in the context of nonhuman primate drug abuse research. PMID:21317354

  4. Proceedings of clinical SPECT (single photon emission computed tomography) symposium

    Energy Technology Data Exchange (ETDEWEB)

    1986-09-01

    It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have selected the key areas which demand awareness and attention in order to make SPECT operational in clinical practice. These include selection of equipment, details of uniformity correction, utilization of phantoms for equipment acceptance and quality assurance, the major aspect of algorithms, an understanding of filtered back projection and appropriate choice of filters and an awareness of the most commonly generated artifacts and how to recognize them. With respect to the acquisition and interpretation of organ images, the faculty will present information on the major aspects of hepatic, brain, cardiac, skeletal, and immunologic imaging techniques. Individual papers are processed separately for the data base. (TEM)

  5. High-resolution PET [Positron Emission Tomography] for Medical Science Studies

    Science.gov (United States)

    Budinger, T. F.; Derenzo, S. E.; Huesman, R. H.; Jagust, W. J.; Valk, P. E.

    1989-09-01

    One of the unexpected fruits of basic physics research and the computer revolution is the noninvasive imaging power available to today's physician. Technologies that were strictly the province of research scientists only a decade or two ago now serve as the foundations for such standard diagnostic tools as x-ray computer tomography (CT), magnetic resonance imaging (MRI), magnetic resonance spectroscopy (MRS), ultrasound, single photon emission computed tomography (SPECT), and positron emission tomography (PET). Furthermore, prompted by the needs of both the practicing physician and the clinical researcher, efforts to improve these technologies continue. This booklet endeavors to describe the advantages of achieving high resolution in PET imaging.

  6. Role of Positron Emission Tomography-Computed Tomography in the Management of Anal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Mistrangelo, Massimiliano, E-mail: mistrangelo@katamail.com [Digestive and Colorectal Surgical Department, Centre of Minimal Invasive Surgery, University of Turin, Molinette Hospital, Turin (Italy); Pelosi, Ettore [PET Center IRMET spa, Turin (Italy); Bello, Marilena [Department of Nuclear Medicine, University of Turin, Molinette Hospital (Italy); Ricardi, Umberto [Department of Radiotherapy, University of Turin, Molinette Hospital (Italy); Milanesi, Enrica [Oncological Centre for Gastrointestinal Neoplasms, University of Turin, Molinette Hospital (Italy); Cassoni, Paola [Department of Biomedical Sciences and Human Oncology, University of Turin, Molinette Hospital (Italy); Baccega, Massimo [Department of Nuclear Medicine, Molinette Hospital (Italy); Filippini, Claudia [Anaesthesia and Intensive Care Unit, University of Turin, Molinette Hospital (Italy); Racca, Patrizia [Oncological Centre for Gastrointestinal Neoplasms, University of Turin, Molinette Hospital (Italy); Lesca, Adriana [Department of Nuclear Medicine, Molinette Hospital (Italy); Munoz, Fernando H. [Department of Radiotherapy, University of Turin, Molinette Hospital (Italy); Fora, Gianluca [Oncological Centre for Gastrointestinal Neoplasms, University of Turin, Molinette Hospital (Italy); Skanjeti, Andrea [Department of Nuclear Medicine, University of Turin, Molinette Hospital (Italy); Cravero, Francesca; Morino, Mario [Digestive and Colorectal Surgical Department, Centre of Minimal Invasive Surgery, University of Turin, Molinette Hospital, Turin (Italy)

    2012-09-01

    Purpose: Pre- and post-treatment staging of anal cancer are often inaccurate. The role of positron emission tomograpy-computed tomography (PET-CT) in anal cancer is yet to be defined. The aim of the study was to compare PET-CT with CT scan, sentinel node biopsy results of inguinal lymph nodes, and anal biopsy results in staging and in follow-up of anal cancer. Methods and Materials: Fifty-three consecutive patients diagnosed with anal cancer underwent PET-CT. Results were compared with computed tomography (CT), performed in 40 patients, and with sentinel node biopsy (SNB) (41 patients) at pretreatment workup. Early follow-up consisted of a digital rectal examination, an anoscopy, a PET-CT scan, and anal biopsies performed at 1 and 3 months after the end of treatment. Data sets were then compared. Results: At pretreatment assessment, anal cancer was identified by PET-CT in 47 patients (88.7%) and by CT in 30 patients (75%). The detection rates rose to 97.9% with PET-CT and to 82.9% with CT (P=.042) when the 5 patients who had undergone surgery prior to this assessment and whose margins were positive at histological examination were censored. Perirectal and/or pelvic nodes were considered metastatic by PET-CT in 14 of 53 patients (26.4%) and by CT in 7 of 40 patients (17.5%). SNB was superior to both PET-CT and CT in detecting inguinal lymph nodes. PET-CT upstaged 37.5% of patients and downstaged 25% of patients. Radiation fields were changed in 12.6% of patients. PET-CT at 3 months was more accurate than PET-CT at 1 month in evaluating outcomes after chemoradiation therapy treatment: sensitivity was 100% vs 66.6%, and specificity was 97.4% vs 92.5%, respectively. Median follow-up was 20.3 months. Conclusions: In this series, PET-CT detected the primary tumor more often than CT. Staging of perirectal/pelvic or inguinal lymph nodes was better with PET-CT. SNB was more accurate in staging inguinal lymph nodes.

  7. Value of positron emission tomography and computer tomography (PET/CT) for urologic malignancies; Interet de la tomographie par emission de positons couplee a la scanographie (TEP/TDM) dans les cancers urologiques

    Energy Technology Data Exchange (ETDEWEB)

    Boujelbene, N.; Mirimanoff, R.O.; Ozsahin, M.; Zouhair, A. [Service de radio-oncologie, CHU Vaudois (CHUV), rue du Bugnon 46, CH-1011 Lausanne (Switzerland); Prior, J.O.; Boubaker, A. [Service de medecine nucleaire, CHU Vaudois (CHUV), rue du Bugnon 46, CH-1011 Lausanne (Switzerland); Azria, D. [Service de radio-oncologie, CRLC Val d' Aurelle-Paul-Lamarque, rue Croix-Verte, parc Euromedecine, 34298 Montpellier cedex 5 (France); Universite Montpellier I, 5, boulevard Henri-IV, CS 19044, 34967 Montpellier cedex (France); Schaffer, M. [Service de radio-oncologie, Ludwig-Maximilians-Universitaet Muenchen, Marchioninistr. 15, 81377 Munich (Germany); Gez, E. [Service de radio-oncologie, The Tel Aviv Sourasky Medical Center, 6 Weizmann Street, Tel Aviv 64239 (Israel); Jichlinski, P. [Service d' urologie, CHU Vaudois (CHUV), rue du Bugnon 46, CH-1011 Lausanne (Switzerland); Meuwly, J.Y. [Service de radiologie, CHU Vaudois (CHUV), rue du Bugnon 46, CH-1011 Lausanne (Switzerland)

    2011-07-15

    Positron emission tomography is a functional imaging technique that allows the detection of the regional metabolic rate, and is often coupled with other morphological imaging technique such as computed tomography. The rationale for its use is based on the clearly demonstrated fact that functional changes in tumor processes happen before morphological changes. Its introduction to the clinical practice added a new dimension in conventional imaging techniques. This review presents the current and proposed indications of the use of positron emission/computed tomography for prostate, bladder and testes, and the potential role of this exam in radiotherapy planning. (authors)

  8. 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography for Other Thyroid Cancers: Medullary, Anaplastic, Lymphoma and So Forth.

    Science.gov (United States)

    Araz, Mine; Çayır, Derya

    2017-02-05

    Positron emission tomography/computed tomography (PET/CT) with 18F-fluorodeoxyglucose (FDG) is used in staging, restaging, and evaluation of therapy response in many cancers as well as differentiated thyroid carcinomas especially in non-iodine avid variants. Its potential in less frequent thyroid tumors like medullary, anaplastic thyroid cancers, thyroid lymphoma and metastatic tumors of the thyroid however, is not well established yet. The aim of this review is to provide an overview on the recent applications and indications of 18F-FDG PET/CT in these tumors and to focus on the controversies in the clinical setting.

  9. Recurrent proliferating trichilemmal tumor with malignant change on the f-18 fluorodeoxyglucose position emission tomography/computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Eun Ha; Kim, Eun Ha; Kim, Young Jun; Yoo, Seol Bong; Nam, Kyung Hwa [Presbyterian Medical Center, Seonam University College of Medicine, Jeonju (Korea, Republic of)

    2016-06-15

    F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography scan has been used for the diagnosis, assessment of treatment response, and follow-up of various neoplasms. Proliferating trichilemmal cyst or tumor (PTT) is a rare neoplasm, originated from the outer root sheath of a hair follicle. Because this tumor has unpredictable biological and clinical behavior, the long-term clinical follow-up is necessary to detect metastasis or recurrence. We reported a case of recurrent malignant PTT on scalp that showed increased FDG uptake.

  10. Data on analysis of coronary atherosclerosis on computed tomography and 18F-sodium fluoride positron emission tomography

    Directory of Open Access Journals (Sweden)

    Toshiro Kitagawa

    2017-08-01

    Full Text Available This article contains the data showing illustrative examples of plaque classification on coronary computed tomography angiography (CCTA and measurement of 18F-sodium fluoride (18F-NaF uptake in coronary atherosclerotic lesions on positron emission tomography (PET. We divided the lesions into one of three plaque types on CCTA (calcified plaque, non-calcified plaque, partially calcified plaque. Focal 18F-NaF uptake of each lesion was quantified using maximum tissue-to-background ratio. This article also provides a representative case with a non-calcified coronary plaque detected on CCTA and identified on 18F-NaF PET/non-contrast computed tomography based on a location of a vessel branch as a landmark. These complement the data reported by Kitagawa et al. (2017 [1].

  11. [Systematic review of the value of positron emission tomography in the diagnosis of Alzheimer's disease].

    Science.gov (United States)

    Carnero-Pardo, C

    A great deal of controversy has arisen about the role positron emission tomography (PET) has to play in the diagnostic assessment of Alzheimer s disease (AD). AIMS. The objective of this study is to review, assess and synthesize existing evidence about the value of PET in the prediction of the progression towards dementia undergone by subjects with mild cognitive impairment and in the differential diagnosis of AD from other types of dementia. We performed a systematic review with explicit search criteria in primary and secondary databases in order to locate documents that could serve our research purposes. Selection and assessment of the quality of the documents found was performed according to a set of pre established criteria. The search for secondary sources yielded nine technical reports, a clinical guideline and a systematic review. To sum up their conclusions it would appear that little work has been published, it is of poor quality and the findings are against the routine use of this technology. The search in primary sources produced three original scientific papers dealing with its value in prediction and two others that referred to differential diagnosis; this new evidence did not, however, modify the previous conclusions. At present, and according to available evidence, the routine use of PET cannot be recommended in the diagnostic assessment of AD. The number of original works available is very low and, generally speaking, they offer important methodological limitations.

  12. Radiolabelled molecules for imaging the translocator protein (18 kDa) using positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Dolle, F.; Luus, C.; Reynolds, A.; Kassiou, M. [CEA, Institut d' Imagerie BioMedicale, Service Hospitalier Frederic Joliot, Orsay (France)

    2009-07-01

    The translocator protein (18 kDa) (TSPO), formerly known as the peripheral benzodiazepine receptor (PBR), was originally identified as an alternate binding site for the central benzodiazepine receptor (CBR) ligand, diazepam, in the periphery, but has now been distinguished as a novel site. The TSPO is ubiquitously expressed in peripheral tissues but only minimally in the healthy brain and increased levels of TSPO expression have been noted in neuro inflammatory conditions such as Alzheimer's disease, Parkinson's disease and stroke. This increase in TSPO expression has been reported to coincide with the process of micro-glial activation, whereby the brain's intrinsic immune system becomes active. Therefore, by using recently developed high affinity, selective TSPO ligands in conjunction with functional imaging modalities such as positron emission tomography (PET), it becomes possible to study the process of micro-glial activation in the living brain. A number of high affinity ligands, the majority of which are C, N-substituted acetamide derivatives, have been successfully radiolabelled and used in in vivo studies of the TSPO and the process of micro-glial activation. This review highlights recent achievements (up to December 2008) in the field of functional imaging of the TSPO as well as the radio-syntheses involved in such studies. (authors)

  13. Computed tomography and (18)F-fluorodeoxyglucose positron emission tomography/computed tomography findings in adrenal candidiasis and histoplasmosis: two cases.

    Science.gov (United States)

    Altinmakas, Emre; Guo, Ming; Kundu, Uma R; Habra, Mouhammed Amir; Ng, Chaan

    2015-01-01

    We report the contrast-enhanced computed tomography (CT) and (18)F-fluorodeoxyglucose positron emission tomography findings in adrenal histoplasmosis and candidiasis. Both demonstrated bilateral hypermetabolic heterogeneous adrenal masses with limited wash-out on delayed CT. Adrenal candidiasis has not been previously reported, nor have the CT wash-out findings in either infection. The adrenal imaging findings are indistinguishable from malignancy, which is more common; but in this setting, physicians should be alert to the differential diagnosis of fungal infections, since it can be equally deadly. Published by Elsevier Inc.

  14. Single photon emission computed tomography and serial MRI in preterm infants with kernicterus.

    Science.gov (United States)

    Okumura, Akihisa; Hayakawa, Fumio; Maruyama, Koichi; Kubota, Tetsuo; Kato, Katsuhiko; Watanabe, Kazuyoshi

    2006-07-01

    Single photon emission computed tomography was performed in three preterm infants with athetoid cerebral palsy due to kernicterus. No clinical signs and symptoms of kernicterus, or ultrasonographic abnormalities were seen during the neonatal period in any patients. Although MRI during infancy revealed high intensity areas in bilateral globi pallidi in all of them, MRI abnormalities were mild in two of them. On later MRI, subtle high intensity areas in the globi pallidi were recognized in only one of them. Single photon emission computed tomography demonstrated hypoperfusion in the basal ganglia regions in all patients. Regions of interest analyses showed decreased blood flow in the basal ganglia related to the cortical areas. Single photon emission computed tomography will be useful for the diagnosis of kernicterus, whereas MRI abnormalities become less clear beyond infancy.

  15. Synthesis and positron emission tomography studies of carbon-11-labeled imatinib (Gleevec)

    Energy Technology Data Exchange (ETDEWEB)

    Kil, Kun-Eek [Medical Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); Department of Chemistry, State University of New York at Stony Brook, Stony Brook, NY 11794-3400 (United States); Ding Yushin [Department of Radiology, Yale University School of Medicine, New Haven, CT 06520-8048 (United States); Lin Kuoshyan [Department of Radiology, University of Pittsburgh, Pittsburgh, PA 15213 (United States); Alexoff, David [Medical Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); Kim, Sung Won [Medical Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); Department of Chemistry, State University of New York at Stony Brook, Stony Brook, NY 11794-3400 (United States); Shea, Colleen [Medical Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); Xu Youwen [Medical Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); Muench, Lisa [Medical Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); Fowler, Joanna S. [Medical Department, Brookhaven National Laboratory, Upton, NY 11973 (United States) and Department of Chemistry, State University of New York at Stony Brook, Stony Brook, NY 11794-3400 (United States)]. E-mail: fowler@bnl.gov

    2007-02-15

    Introduction: Imatinib mesylate (Gleevec) is a well known drug for treating chronic myeloid leukemia and gastrointestinal stromal tumors. Its active ingredient, imatinib ([4-[(4-methyl-1-piperazinyl)methyl]-N-[4-methyl-3-[[4-(3-pyridyl) -2-pyrimidinyl]amino]phenyl]benzamide), blocks the activity of several tyrosine kinases. Here we labeled imatinib with carbon-11 as a tool for determining the drug distribution and pharmacokinetics of imatinib, and we carried out positron emission tomography (PET) studies in baboons. Methods: [N-{sup 11}C-methyl]imatinib was synthesized from [{sup 11}C]methyl iodide and norimatinib was synthesized by the demethylation of imatinib (isolated from Gleevec tablets) according to a patent procedure [Collins JM, Klecker RW Jr, Anderson LW. Imaging of drug accumulation as a guide to antitumor therapy. US Patent 20030198594A1, 2003]. Norimatinib was also synthesized from the corresponding amine and acid. PET studies were carried out in three baboons to measure pharmacokinetics in the brain and peripheral organs and to determine the effect of a therapeutic dose of imatinib. Log D and plasma protein binding were also measured. Results: [N-{sup 11}C-methyl]imatinib uptake in the brain is negligible (consistent with P-glycoprotein-mediated efflux); it peaks and clears rapidly from the heart, lungs and spleen. Peak uptake and clearance occur more slowly in the liver and kidneys, followed by accumulation in the gallbladder and urinary bladder. Pretreatment with imatinib did not change uptake in the heart, lungs, kidneys and spleen, and increased uptake in the liver and gallbladder. Conclusions: [N-{sup 11}C-methyl]imatinib has potential for assessing the regional distribution and kinetics of imatinib in the human body to determine whether the drug targets tumors and to identify other organs to which the drug or its labeled metabolites distribute. Paired with tracers such as 2'deoxy-2'-[{sup 18}F]fluoro-D-glucose ({sup 18}FDG) and 3&apos

  16. Respiratory motion in positron emission tomography for oncology applications: Problems and solutions

    Energy Technology Data Exchange (ETDEWEB)

    Visvikis, D. [INSERM U650, LaTIM, University Hospital Medical School, F-29609, Brest (France)]. E-mail: Visvikis.Dimitris@univ-brest.fr; Lamare, F. [INSERM U650, LaTIM, University Hospital Medical School, F-29609, Brest (France); Bruyant, P. [INSERM U650, LaTIM, University Hospital Medical School, F-29609, Brest (France); Boussion, N. [INSERM U650, LaTIM, University Hospital Medical School, F-29609, Brest (France); Cheze Le Rest, C. [INSERM U650, LaTIM, University Hospital Medical School, F-29609, Brest (France)

    2006-12-20

    The effect of physiological motion in emission tomography is a reduction in overall image contrast and loss of sensitivity. In particular, respiratory motion affects imaging in the thoracic and the upper abdomen area, leading to a reduction in lesion detection as a result of the associated blurring. Furthermore, respiratory motion leads to a compromise in quantitative accuracy in terms of functional volume determination and activity concentration recovery for oncology imaging. This paper presents a review of the current state of the art in the implementation of respiratory motion compensation techniques in positron emission tomography (PET) imaging for oncology applications.

  17. Single-Photon Emission Computerized Tomography (SPECT in Neuropsychiatry: A Review

    Directory of Open Access Journals (Sweden)

    B. K. Puri

    1992-01-01

    Full Text Available Cranial single-photon emission computerized tomography (SPECT or SPET can now give regional cerebral blood flow images with a resolution approaching that of positron emission tomography (PET. In this paper, the use of high resolution SPECT neuroimaging in neuropsychiatric disorders, including Alzheimer's disease, multi-infarct dementia, Pick's disease, progressive supranuclear palsy, Korsakoff's psychosis, Creutzfeld-Jakob disease, Parkinson's disease, Huntington's disease, schizophrenia, mood disorders, obsessive–compulsive disorder, HIV infection and AIDS is reviewed. Finally, further potential research and clinical uses, based on ligand studies, are outlined.

  18. No difference in cardiac event-free survival between positron emission tomography-guided and single-photon emission computed tomography-guided patient management - A prospective, randomized comparison of patients with suspicion of jeopardized myocardium

    NARCIS (Netherlands)

    Siebelink, HMJ; Blanksma, PK; Crijns, HJGM; Bax, JJ; van Boven, AJ; Kingma, T; Piers, DA; Pruim, J; Jager, PL; Vaalburg, W; van der Wall, EE

    OBJECTIVES We sought to prospectively compare nitrogen-13 (N-13)-ammonia/(18)fluorodeoxyglucose ((18)FDG) positron emission tomography (PET)-guided management with stress/rest technetium-99m (Tc-99m)-sestamibi single-photon emission computed tomography (SPECT)-guided management BACKGROUND Patients

  19. Positron emission tomography (PET) study of the alterations in brain pharmacokinetics of methamphetamine in methamphetamine sensitized animals

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Hitoshi [Tohoku Univ., Sendai (Japan). Hospital

    2001-08-01

    I investigated the differences in brain pharmacokinetics of [{sup 11}C]methamphetamine ([{sup 11}C]MAP) in normal and MAP sensitized animals using positron emission tomography (PET). [{sup 11}C]MAP was synthesized by an automated on-line [{sup 11}C]methylation system. I newly produced MAP sensitized dog and monkey by repeated MAP treatment. The maximal level of accumulation of [{sup 11}C]MAP in the sensitized dog brain was 1.4 times higher than that in the control. This result suggests the changes in the pharmacokinetic profile of MAP in the brain affect the development or expression of MAP-induced behavioral sensitization. However, the overaccumulation of [{sup 11}C]MAP in the sensitized monkey brain was not observed due to the influence of anesthesia. (author)

  20. Fluorodeoxyglucose and C-Choline positron emission tomography for distinction of metastatic plexopathy and neuritis : a case report

    NARCIS (Netherlands)

    Bartels, Anna L.; Zeebregts, Clark J; Enting, Roeline; Slart, Riemer Hja

    2009-01-01

    INTRODUCTION: Fluorodeoxyglucose positron emission tomography scanning has an established role in the diagnostic work-up of many malignant diseases and also in the evaluation of cancer treatment response. Fluorodeoxyglucose positron emission tomography may, however be non-specific as infectious

  1. Positron emission tomography/computed tomography and biomarkers for early treatment response evaluation in metastatic colon cancer

    DEFF Research Database (Denmark)

    Engelmann, Bodil E.; Loft, Annika; Kjær, Andreas

    2014-01-01

    BACKGROUND: Treatment options for metastatic colon cancer (mCC) are widening. We prospectively evaluated serial 2-deoxy-2-[18F]fluoro-d-glucose positron-emission tomography/computed tomography (PET/CT) and measurements of tissue inhibitor of metalloproteinases-1 (TIMP-1), carcinoembryonic antigen...... (CEA), and liberated domain I of urokinase plasminogen activator receptor (uPAR(I)) for early assessment of treatment response in mCC patients. METHODS: Thirty-three mCC patients scheduled for first-line chemotherapy with capecitabine and oxaliplatin (CAPOX) and bevacizumab participated; 27 were...... evaluated by PET/CT before treatment, after one and four treatment series. Morphological and metabolic response was independently assessed according to Response Evaluation Criteria in Solid Tumors and European Organization for Research and Treatment of Cancer PET criteria. Plasma TIMP-1, plasma u...

  2. [18F]Fluorodeoxyglucose (FDG)-Positron Emission Tomography (PET)/Computed Tomography (CT) in Suspected Recurrent Breast Cancer

    DEFF Research Database (Denmark)

    Hildebrandt, Malene Grubbe; Gerke, Oke; Baun, Christina

    2016-01-01

    PURPOSE: To prospectively investigate the diagnostic accuracy of [(18)F]fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) with dual-time-point imaging, contrast-enhanced CT (ceCT), and bone scintigraphy (BS) in patients with suspected breast cancer recurrence....... PATIENTS AND METHODS: One hundred women with suspected recurrence of breast cancer underwent 1-hour and 3-hour FDG-PET/CT, ceCT, and BS within approximately 10 days. The study was powered to estimate the precision of the individual imaging tests. Images were visually interpreted using a four...... the receiver operating curve and higher sensitivity, specificity, and superior likelihood ratios. CONCLUSION: FDG-PET/CT was accurate in diagnosing recurrence in breast cancer patients. It allowed for distant recurrence to be correctly ruled out and resulted in only a small number of false-positive cases...

  3. Benign thyroid and neck lesions mimicking malignancy with false positive findings on positron emission tomography-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Ye Ri; Kim, Shin Young; Lee, Sang Mi [Soonchunhyang University Cheonan Hospital, Cheonan (Korea, Republic of); Lee, Deuk Young [Dept. of Surgery, Younsei Angelot Women' s Clinic, Cheonan (Korea, Republic of)

    2017-02-15

    The increasing use of positron emission tomography-computed tomography (PET/CT) has led to the frequent detection of incidental thyroid and neck lesions with increased 18F-deoxyglucose (FDG) uptake. Although lesions with increased FDG uptake are commonly assumed to be malignant, benign lesions may also exhibit increased uptake. The purpose of this pictorial essay is to demonstrate that benign thyroid and neck lesions can produce false-positive findings on PET/CT, and to identify various difficulties in interpretation. It is crucial to be aware that differentiating between benign and malignant lesions is difficult in a considerable proportion of cases, when relying only on PET/CT findings. Correlation of PET/CT findings with additional imaging modalities is essential to avoid misdiagnosis.

  4. Bilateral diffuse fluorodeoxyglucose uptake in thyroid gland diagnosed by fluorodeoxyglucose-positron emission tomography/computed tomography.

    Science.gov (United States)

    Win, Aung Zaw; Aparici, Carina Mari

    2014-05-01

    Our patient is a female who was first diagnosed with breast cancer at the age of 23. A follow-up fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) at age 44 revealed diffuse high FDG uptake in an enlarged thyroid gland. Fine-needle aspiration (FNA) of the thyroid mass revealed estrogen receptor/progesterone receptor negative, human epidermal growth factor receptor 2+ breast cancer. To the best of our knowledge, this is the first case to report breast cancer metastasis to the thyroid in a diffuse pattern on FDG-PET/CT. Bilateral diffuse uptake of FDG in thyroid is the most commonly associated with benign conditions. However, FNA biopsies need to be done to rule out metastatic disease in thyroid lesions with diffuse high FDG uptake, especially for patients with history of cancer.

  5. Lynch Syndrome Associated Colon Adenocarcinoma Resembling Lymphoma on Fluoro-Deoxyglucose-Positron Emission Tomography/Computed Tomography.

    Science.gov (United States)

    Aparici, Carina Mari; Win, Aung Zaw

    2015-01-01

    The patient was a 46-year-old Asian male diagnosed with lynch syndrome associated colon adenocarcinoma in the right ascending colon. A presurgical staging 18-fluoro-deoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) found increased metabolic activity in the cervical, axillary, mediastinal, supraclavicular, para-aortic and mesenteric lymph nodes. This pattern of metastasis was very unusual for lynch syndrome associated colon adenocarcinoma and the involvement of those lymph nodes resembles the pattern of spread of lymphoma. He underwent right hemicolectomy and he was subsequently treated with 12 cycles of folinic acid (leucovorin), fluorouracil (5-FU), irinotecan. A restaging FDG-PET/CT at the end of the chemotherapy showed interval decrease in size and metabolic activity in the affected lymph nodes. FDG-PET/CT is a useful imaging modality in following-up the treatment response in colon adenocarcinoma.

  6. Perineural Spread of Mucoepidermoid Carcinoma of Parotid Gland Involving V, VI, and VII Cranial Nerves Demonstrated on Positron Emission Tomography/Computed Tomography.

    Science.gov (United States)

    Chandra, Piyush; Nath, Satish

    2017-01-01

    Perineural spread (PNS) in head and neck malignancies has been associated with extremely poor prognosis. Through this interesting case, we demonstrate the PNS of a mucoepidermoid carcinoma of parotid gland with simultaneous involvement of V, VI, and VII cranial nerves identified on positron emission tomography/computed tomography.

  7. Patient study of in vivo verification of beam delivery and range, using positron emission tomography and computed tomography imaging after proton therapy

    NARCIS (Netherlands)

    Parodi, Katia; Paganetti, Harald; Shih, Helen A; Michaud, Susan; Loeffler, Jay S; DeLaney, Thomas F; Liebsch, Norbert J; Munzenrider, John E; Fischman, Alan J; Knopf, Antje; Bortfeld, Thomas

    2007-01-01

    PURPOSE: To investigate the feasibility and value of positron emission tomography and computed tomography (PET/CT) for treatment verification after proton radiotherapy. METHODS AND MATERIALS: This study included 9 patients with tumors in the cranial base, spine, orbit, and eye. Total doses of 1.8-3

  8. High-resolution PET (positron emission tomography) for medical science studies

    Energy Technology Data Exchange (ETDEWEB)

    Budinger, T.F.; Derenzo, S.E.; Huesman, R.H.; Jagust, W.J.; Valk, P.E. (Lawrence Berkeley Lab., CA (USA))

    1989-09-01

    One of the unexpected fruits of basic physics research and the computer revolution is the noninvasive imaging power available to today's physician. Technologies that were strictly the province of research scientists only a decade or two ago now serve as the foundations for such standard diagnostic tools as x-ray computer tomography (CT), magnetic resonance imaging (MRI), magnetic resonance spectroscopy (MRS), ultrasound, single photon emission computed tomography (SPECT), and positron emission tomography (PET). Furthermore, prompted by the needs of both the practicing physician and the clinical researcher, efforts to improve these technologies continue. This booklet endeavors to describe the advantages of achieving high resolution in PET imaging. 6 refs., 21 figs.

  9. Positron Emission Tomography Methods with Potential for Increased Understanding of Mental Retardation and Developmental Disabilities

    Science.gov (United States)

    Sundaram, Senthil K.; Chugani, Harry T.; Chugani, Diane C.

    2005-01-01

    Positron emission tomography (PET) is a technique that enables imaging of the distribution of radiolabeled tracers designed to track biochemical and molecular processes in the body after intravenous injection or inhalation. New strategies for the use of radiolabeled tracers hold potential for imaging gene expression in the brain during development…

  10. Fluorine-18-fluorodeoxyglucose Positron Emission Tomography in Diffuse Large B-cell Lymphoma

    DEFF Research Database (Denmark)

    Mylam, Karen Juul; Nielsen, Anne Lerberg; Pedersen, Lars Møller

    2014-01-01

    Diffuse large B-cell lymphoma (DLBCL) is an aggressive and potentially curable type of lymphoma. Fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) is part of clinical routine for DLBCL in most hospitals and also recommended for staging and end-of-therapy evaluation. FDG......-PET assessment methods and the clinical application of FDG-PET for management of DLBCL....

  11. 77 FR 8262 - Draft Guidance on Investigational New Drug Applications for Positron Emission Tomography Drugs...

    Science.gov (United States)

    2012-02-14

    ... HUMAN SERVICES Food and Drug Administration Draft Guidance on Investigational New Drug Applications for Positron Emission Tomography Drugs; Availability AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and Drug Administration (FDA) is announcing the availability of a draft guidance...

  12. Activity-based costing evaluation of a [F-18]-fludeoxyglucose positron emission tomography study

    NARCIS (Netherlands)

    Krug, Bruno; Van Zanten, Annie; Pirson, Anne-Sophie; Crott, Ralph; Vander Borght, Thierry

    2009-01-01

    Objective: The aim of the study is to use the activity-based costing approach to give a better insight in the actual cost structure of a positron emission tomography procedure (FDG-PET) by defining the constituting components and by simulating the impact of possible resource or practice changes.

  13. Detection of unknown primary head and neck tumors by positron emission tomography

    NARCIS (Netherlands)

    Braams, JW; Pruim, J; Kole, AC; Nikkels, PGJ; Vaalburg, W; Vermey, A; Roodenburg, JLN

    The purpose of this study was to investigate the potential of using positron emission tomography (PET) with F-18-labeled fluoro-2-deoxy-D-glucose (FDG) to detect unknown primary tumors of cervical metastases. Thirteen patients with various histologic types of cervical metastases of unknown primary

  14. Small animal positron emission tomography imaging and in vivo studies of atherosclerosis

    DEFF Research Database (Denmark)

    Hag, Anne Mette Fisker; Ripa, Rasmus Sejersten; Pedersen, Sune Folke

    2013-01-01

    Atherosclerosis is a growing health challenge globally, and despite our knowledge of the disease has increased over the last couple of decades, many unanswered questions remain. As molecular imaging can be used to visualize, characterize and measure biological processes at the molecular and cellu...... knowledge obtained from in vivo positron emission tomography studies of atherosclerosis performed in small animals....

  15. Preoperative staging of non-small-cell lung cancer with positron-emission tomography.

    NARCIS (Netherlands)

    Pieterman, RM; van Putten, JWG; Meuzelaar, JJ; Mooyaart, EL; Vaalburg, W; Koeter, GH; Fidler, [No Value; Pruim, J; Groen, HJM

    2000-01-01

    Background: Determining the stage of non-small-cell lung cancer often requires multiple preoperative tests and invasive procedures. Whole-body positron-emission tomography (PET) may simplify and improve the evaluation of patients with this tumor. Methods: We prospectively compared the ability of a

  16. Visualization of prostate cancer with C-11-choline positron emission tomography

    NARCIS (Netherlands)

    de Jong, IJ; Pruim, J; Elsinga, PH; Vaalburg, W; Mensink, HJA

    Background and Objective: Visualization of prostate cancer with positron emission tomography (PET) using 2-[F-18]2-deoxy-D-glucose (FDG) as radiopharmaceutical is limited by the low uptake of FDG in the tumor and by radioactivity excreted into the bladder. More specific PET radiopharmaceuticals

  17. A method for calculating regional cerebral blood flow from emission computed tomography of inert gas concentrations

    DEFF Research Database (Denmark)

    Celsis, P; Goldman, T; Henriksen, L

    1981-01-01

    Emission tomography of positron or gamma emitting inert gases allows calculation of regional cerebral blood flow (rCBF) in cross-sectional slices of human brain. An algorithm is presented for rCBF calculations from a sequence of time averaged tomograms using inhaled 133Xe. The approach is designed...

  18. Novel targets for positron emission tomography (PET) radiopharmaceutical tracers for visualization of neuroinflammation

    Science.gov (United States)

    Shchepetkin, I.; Shvedova, M.; Anfinogenova, Y.; Litvak, M.; Atochin, D.

    2017-08-01

    Non-invasive molecular imaging techniques can enhance diagnosis of neurological diseases to achieve their successful treatment. Positron emission tomography (PET) imaging can identify activated microglia and provide detailed functional information based on molecular biology. This imaging modality is based on detection of isotope labeled tracers, which emit positrons. The review summarizes the developments of various radiolabeled ligands for PET imaging of neuroinflammation.

  19. Multiple pulmonary sclerosing hemangiomas (pneumocytoma) mimicking lung metastasis detected in fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography.

    Science.gov (United States)

    Kamaleshwaran, Koramadai Karuppusamy; Rajan, Firoz; Mehta, Sangita; Mohanan, Vyshakh; Shinto, Ajit Sugunan

    2014-07-01

    Pulmonary sclerosing hemangioma (PSH), or the alternative name of "sclerosing pneumocytoma," is a rare benign neoplasm. PSH is often asymptomatic and presents as a solitary or multiple pulmonary nodules on radiologic imaging studies. Few articles have been reported to describe the fluorodeoxyglucose positron emission tomography (FDG PET) findings about PSH. The authors describe an interesting but uncommonly encountered cause of false positive FDG PET scan in the thorax in a 25-year-old woman, a known case of arteriovenous malformation of oral cavity who underwent embolization and presented with incidental detection of bilateral lung nodules. She is asymptomatic and is on follow-up.

  20. Positron Emission Tomography: Current Challenges and Opportunities for Technological Advances in Clinical and Preclinical Imaging Systems.

    Science.gov (United States)

    Vaquero, Juan José; Kinahan, Paul

    2015-01-01

    Positron emission tomography (PET) imaging is based on detecting two time-coincident high-energy photons from the emission of a positron-emitting radioisotope. The physics of the emission, and the detection of the coincident photons, give PET imaging unique capabilities for both very high sensitivity and accurate estimation of the in vivo concentration of the radiotracer. PET imaging has been widely adopted as an important clinical modality for oncological, cardiovascular, and neurological applications. PET imaging has also become an important tool in preclinical studies, particularly for investigating murine models of disease and other small-animal models. However, there are several challenges to using PET imaging systems. These include the fundamental trade-offs between resolution and noise, the quantitative accuracy of the measurements, and integration with X-ray computed tomography and magnetic resonance imaging. In this article, we review how researchers and industry are addressing these challenges.

  1. Increased fluoro-deoxy-D-glucose uptake on positron emission tomography-computed tomography postbronchoalveolar lavage: a potential cause of radiologic misinterpretation.

    LENUS (Irish Health Repository)

    Leong, Sum

    2011-08-01

    Cytologic analysis of bronchoalveolar lavage (BAL) fluid is used for lung cancer diagnosis. We describe a patient with a history of rectal carcinoma who presented with a new lung mass. BAL was performed, with positron emission tomography-computed tomography the following day. There was mildly increased fluoro-deoxy-D-glucose uptake in areas of the lung parenchyma with new ground-glass opacification. This created ambiguity in staging, clarified 2 weeks later by a computed tomography showing complete resolution of the ground-glass opacity. Clinicians should be aware that BAL may cause increased pulmonary fluoro-deoxy-D-glucose uptake, making accurate radiologic interpretation problematic. We suggest that to optimize positron emission tomography-computed tomography, studies should not be performed within 24 hours of BAL.

  2. The positrons emission tomography in cardiology on expecting for the rubidium 82; La tomographie par emission de positons en cardiologie en attendant le rubidium-82

    Energy Technology Data Exchange (ETDEWEB)

    Agostini, D. [Societe Francaise de Cardiologie Nucleaire et IRM, 75 - Paris (France)

    2005-11-15

    The positron emission tomography in cardiology has an important place in France. A new tracer, the rubidium 82 can be used for the detection of myocardium ischemia among the patients where the SPECT was ineffective or not very useful, it will be necessary to propose a permit to market the tracer in the two next years.Recently, the Food drug administration in Usa has allowed the repayment of the rubidium 82 for the myocardium detection as normal or abnormal in the post myocardium infarction. (N.C.)

  3. Degenerative dementia: nosological aspects and results of single photon emission computed tomography; Les demences degeneratives: aspects nosologiques et resultats de la tomographie d'emission monophotonique

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, B.; Habert, M.O. [Hopital Pitie-Salpetriere, 75 - Paris (France)

    1999-12-01

    Ten years ago, the diagnosis discussion of a dementia case for the old patient was limited to two pathologies: the Alzheimer illness and the Pick illness. During these last years, the frame of these primary degenerative dementia has fallen into pieces. The different diseases and the results got with single photon emission computed tomography are discussed. for example: fronto-temporal dementia, primary progressive aphasia, progressive apraxia, visio-spatial dysfunction, dementia at Lewy's bodies, or cortico-basal degeneration. (N.C.)

  4. Focal nodular hyperplasia (FNH): a potential cause of false-positive positron emission tomography.

    Science.gov (United States)

    Aznar, D López; Ojeda, Reyes; Garcia, E Uruburu; Aparici, F; Sánchez, P Abreu; Flores, D; Martínez, C; Sopena, R

    2005-09-01

    Positron emission tomography (PET) using F-18 fluorodeoxyglucose (FDG) has been proven to be a useful tool in the differential diagnosis of liver tumors. Focal nodular hyperplasia (FNH) is an uncommon benign liver lesion, which can be difficult to differentiate from other benign and malignant liver pathologies. FDG PET imaging usually shows uptake similar or even decreased compared to that of the normal liver. We describe a hypermetabolic FNH lesion in a patient with a history of breast cancer. Computed tomography scan, ultrasonography (US), and magnetic resonance imaging were negative. The lesion was resected, and histologic findings were consistent with FNH.

  5. Synthesis and Characterization of Theranostic Poly(HPMA)-c(RGDyK)-DOTA-64Cu Copolymer Targeting Tumor Angiogenesis: Tumor Localization Visualized by Positron Emission Tomography

    OpenAIRE

    Jianchao Yuan; Haiyuan Zhang; Harpreet Kaur; David Oupicky; Fangyu Peng

    2013-01-01

    Poly(HPMA)-c(RGDyK)-DOTA-64Cu copolymers were synthesized and characterized for tumor localization in vivo as a theranostic scaffold for cancer imaging and anticancer drug delivery targeting tumor angiogenesis. Tumor localization of the poly(HPMA)-c(RGDyK)-DOTA-64Cu copolymers was visualized in mice bearing human prostate cancer xenografts by positron emission tomography (PET) using a microPET scanner. PET quantitative analysis demonstrated that tumor 64Cu radioactivity (2.75 ± 0.34 %ID/g) in...

  6. HaloTag as a reporter gene: positron emission tomography imaging with 64Cu-labeled second generation HaloTag ligands

    OpenAIRE

    Hong, Hao; Benink, Hélène A.; Uyeda, H. Tetsuo; Valdovinos, Hector F.; Zhang, Yin; Meisenheimer, Poncho; Barnhart, Todd E.; Fan, Frank; Cai, Weibo

    2013-01-01

    The goal of this study is to employ the HaloTag technology for positron emission tomography (PET), which involves two components: the HaloTag protein (a modified hydrolase which covalently binds to synthetic ligands) and HaloTag ligands (HTLs). 4T1 murine breast cancer cells were stably transfected to express HaloTag protein on the surface (termed as 4T1-HaloTag-ECS, ECS denotes extracellular surface). Two new HTLs were synthesized and termed NOTA-HTL2G-S and NOTA-HTL2G-L (2G indicates second...

  7. Evaluation of dosimetry and image of very low-dose computed tomography attenuation correction for pediatric positron emission tomography/computed tomography: phantom study

    Science.gov (United States)

    Bahn, Y. K.; Park, H. H.; Lee, C. H.; Kim, H. S.; Lyu, K. Y.; Dong, K. R.; Chung, W. K.; Cho, J. H.

    2014-04-01

    In this study, phantom was used to evaluate attenuation correction computed tomography (CT) dose and image in case of pediatric positron emission tomography (PET)/CT scan. Three PET/CT scanners were used along with acryl phantom in the size for infant and ion-chamber dosimeter. The CT image acquisition conditions were changed from 10 to 20, 40, 80, 100 and 160 mA and from 80 to 100, 120 and 140 kVp, which aimed at evaluating penetrate dose and computed tomography dose indexvolume (CTDIvol) value. And NEMA PET Phantom™ was used to obtain PET image under the same CT conditions in order to evaluate each attenuation-corrected PET image based on standard uptake value (SUV) value and signal-to-noise ratio (SNR). In general, the penetrate dose was reduced by around 92% under the minimum CT conditions (80 kVp and 10 mA) with the decrease in CTDIvol value by around 88%, compared with the pediatric abdomen CT conditions (100 kVp and 100 mA). The PET image with its attenuation corrected according to each CT condition showed no change in SUV value and no influence on the SNR. In conclusion, if the minimum dose CT that is properly applied to body of pediatric patient is corrected for attenuation to ensure that the effective dose is reduced by around 90% or more compared with that for adult patient, this will be useful to reduce radiation exposure level.

  8. WAVELET ANALYSIS OF REAL EAR AND SYNTHESIZED CLICK-EVOKED OTOACOUSTIC EMISSIONS

    NARCIS (Netherlands)

    WIT, HP; VANDIJK, P; AVAN, P

    Wavelet analysis was performed to obtain time-frequency analyses of click evoked otoacoustic emissions from normal ears and one ear with a high-frequency hearing loss; mainly to introduce this relatively new method and to show its potentials for emission analysis. The same analysis was then used to

  9. Existing Pittsburgh Compound-B positron emission tomography thresholds are too high: statistical and pathological evaluation.

    Science.gov (United States)

    Villeneuve, Sylvia; Rabinovici, Gil D; Cohn-Sheehy, Brendan I; Madison, Cindee; Ayakta, Nagehan; Ghosh, Pia M; La Joie, Renaud; Arthur-Bentil, Samia Kate; Vogel, Jacob W; Marks, Shawn M; Lehmann, Manja; Rosen, Howard J; Reed, Bruce; Olichney, John; Boxer, Adam L; Miller, Bruce L; Borys, Ewa; Jin, Lee-Way; Huang, Eric J; Grinberg, Lea T; DeCarli, Charles; Seeley, William W; Jagust, William

    2015-07-01

    Amyloid-β, a hallmark of Alzheimer's disease, begins accumulating up to two decades before the onset of dementia, and can be detected in vivo applying amyloid-β positron emission tomography tracers such as carbon-11-labelled Pittsburgh compound-B. A variety of thresholds have been applied in the literature to define Pittsburgh compound-B positron emission tomography positivity, but the ability of these thresholds to detect early amyloid-β deposition is unknown, and validation studies comparing Pittsburgh compound-B thresholds to post-mortem amyloid burden are lacking. In this study we first derived thresholds for amyloid positron emission tomography positivity using Pittsburgh compound-B positron emission tomography in 154 cognitively normal older adults with four complementary approaches: (i) reference values from a young control group aged between 20 and 30 years; (ii) a Gaussian mixture model that assigned each subject a probability of being amyloid-β-positive or amyloid-β-negative based on Pittsburgh compound-B index uptake; (iii) a k-means cluster approach that clustered subjects into amyloid-β-positive or amyloid-β-negative based on Pittsburgh compound-B uptake in different brain regions (features); and (iv) an iterative voxel-based analysis that further explored the spatial pattern of early amyloid-β positron emission tomography signal. Next, we tested the sensitivity and specificity of the derived thresholds in 50 individuals who underwent Pittsburgh compound-B positron emission tomography during life and brain autopsy (mean time positron emission tomography to autopsy 3.1 ± 1.8 years). Amyloid at autopsy was classified using Consortium to Establish a Registry for Alzheimer's Disease (CERAD) criteria, unadjusted for age. The analytic approaches yielded low thresholds (standard uptake value ratiolow = 1.21, distribution volume ratiolow = 1.08) that represent the earliest detectable Pittsburgh compound-B signal, as well as high thresholds (standard

  10. Brain metabolism in autism. Resting cerebral glucose utilization rates as measured with positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Rumsey, J.M.; Duara, R.; Grady, C.; Rapoport, J.L.; Margolin, R.A.; Rapoport, S.I.; Cutler, N.R.

    1985-05-01

    The cerebral metabolic rate for glucose was studied in ten men (mean age = 26 years) with well-documented histories of infantile autism and in 15 age-matched normal male controls using positron emission tomography and (F-18) 2-fluoro-2-deoxy-D-glucose. Positron emission tomography was completed during rest, with reduced visual and auditory stimulation. While the autistic group as a whole showed significantly elevated glucose utilization in widespread regions of the brain, there was considerable overlap between the two groups. No brain region showed a reduced metabolic rate in the autistic group. Significantly more autistic, as compared with control, subjects showed extreme relative metabolic rates (ratios of regional metabolic rates to whole brain rates and asymmetries) in one or more brain regions.

  11. Estrogen Sulfotransferase-Mediated Imaging with Positron Emission Tomography in Moyamoya Syndrome

    OpenAIRE

    Surmak, Andrew John

    2017-01-01

    Moyamoya syndrome presents a cerebrovascular pathology that progressively introduces chronic ischemia. The network of collateral vessels created in response to arterial stenosis causes hypoperfusion and stimulates inflammatory insults that jeopardize the brain. Within this study, we used positron emission tomography (PET) to image inflammatory responses in patients with moyamoya syndrome and present the first report of [11C]-PiB in moyamoya patients. [11C]-PiB has a high affinity for estrogen...

  12. An Application of Micro-channel Plate Photomultiplier Tube to Positron Emission Tomography

    OpenAIRE

    Kim, H.; Chen, C. -T.; Frisch, H.; Tang, F.; Kao, C.-M.

    2012-01-01

    We are developing a Time-of-Flight Positron Emission Tomography detector using flat panel micro-channel plate photomultiplier tubes (MCP PMT). The high-speed waveform sampling data acquisition is adopted to exploit the fast time response of MCP PMT efficiently by using transmission-line readout scheme. To demonstrate the feasibility of the proposed detector, prototype detector modules were built using Photonis XP85022 MCP PMT, transmission-line board (TL), and high-speed waveform sampling ele...

  13. 18F-Labeling of Sensitive Biomolecules for Positron Emission Tomography

    Science.gov (United States)

    Krishnan, Hema S.; Ma, Longle; Vasdev, Neil; Liang, Steven H.

    2017-01-01

    Positron emission tomography (PET) imaging study of fluorine-18 labeled biomolecules is an emerging and rapidly growing area for preclinical and clinical research. The present review focuses on recent advances in radiochemical methods for incorporating fluorine-18 into biomolecules via ‘direct’ or ‘indirect’ bioconjugation. Recently developed prosthetic groups and pre-targeting strategies, as well as representative examples in 18F-labeling of biomolecules in PET imaging research studies are highlighted. PMID:28704575

  14. PET and Single-Photon Emission Computed Tomography in Brain Concussion.

    Science.gov (United States)

    Raji, Cyrus A; Henderson, Theodore A

    2018-02-01

    This article offers an overview of the application of PET and single photon emission computed tomography brain imaging to concussion, a type of mild traumatic brain injury and traumatic brain injury, in general. The article reviews the application of these neuronuclear imaging modalities in cross-sectional and longitudinal studies. Additionally, this article frames the current literature with an overview of the basic physics and radiation exposure risks of each modality. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Dosage optimization in positron emission tomography: state-of-the-art methods and future prospects

    OpenAIRE

    Karakatsanis, Nicolas A; Fokou, Eleni; Tsoumpas, Charalampos

    2015-01-01

    Positron emission tomography (PET) is widely used nowadays for tumor staging and therapy response in the clinic. However, average PET radiation exposure has increased due to higher PET utilization. This study aims to review state-of-the-art PET tracer dosage optimization methods after accounting for the effects of human body attenuation and scan protocol parameters on the counting rate. In particular, the relationship between the noise equivalent count rate (NECR) and the dosage (NECR-dosage ...

  16. Single photon emission computed tomography using perfusion tracers in seizure disorders.

    Science.gov (United States)

    Dierckx, R A; Vandevivere, J; Dom, L; Melis, K; Janssens, G; Dobbeleir, A; De Deyn, P P

    1992-07-01

    Single photon emission computed tomography (SPECT) using perfusion tracers makes it possible to estimate regional cerebral blood flow (rCBF) and, indirectly, local brain metabolism. It may be possible to detect and follow physiopathological alterations, such as may be seen in seizure disorders. The authors review the principles of and some data on perfusion SPECT in seizure disorders, stress advantages as well as major drawbacks and add their initial experience with Tc-99m hexamethylpropyleneamine oxime (HMPAO) SPECT in febrile convulsions.

  17. Oscillator based analog to digital converters applied for charge based radiation detectors in positron emission tomography

    OpenAIRE

    Völker, M.

    2014-01-01

    This thesis presents the development of a readout strategy and a front-end for radiation detectors especially adapted for positron emission tomography. The developed front-end is optimized for the implementation in modern CMOS technologies. On one hand, most of the signal processing is transferred into the digital domain to benefit from the high digital integration density. On the other hand, the circuits have to be robust against cross-talk and power supply noise. Low-power design methods ar...

  18. Hot water epilepsy: Phenotype and single photon emission computed tomography observations

    OpenAIRE

    Mehul Patel; Parthasarathy Satishchandra; Hanumanthapura Aravinda; Bharath, Rose D.; Sanjib Sinha

    2014-01-01

    We studied the anatomical correlates of reflex hot water epilepsy (HWE) using multimodality investigations viz. magnetic resonance imaging (MRI), electroencephalography (EEG), and single photon emission computed tomography (SPECT). Five men (mean age: 27.0 ΁ 5.8 years) with HWE were subjected to MRI of brain, video-EEG studies, and SPECT scan. These were correlated with phenotypic presentations. Seizures could be precipitated in three patients with pouring of hot water over the head and semio...

  19. Usefulness of myocardial positron emission tomography/nuclear imaging in Takotsubo cardiomyopathy.

    Science.gov (United States)

    Testa, Marzia; Feola, Mauro

    2014-07-28

    To analyse and summarize all the articles related to positron emission tomography and Takotsubo cardiomyopathy (TTC). We performed a systematic review of the existing literature on positron emission tomography/nuclear imaging and Takotsubo cardiomyopathy using PUBMED database. We combined search terms such as "takotsubo", "takotsubo syndrome", "myocardial positron emission tomography", "positron emission tomography". All case reports were excluded. The list included only four articles which were reviewed by two independent investigators. It was not possible to undertake a formal meta-analysis because of the heterogeneity of the studies; therefore, we made a narrative synthesis of the collected data. Nuclear medicine techniques can be useful employed in the differential diagnosis of TTC from an acute coronary syndrome (ACS). In fact, transient left ventricular (LV) apical ballooning is a syndrome frequently misdiagnosed as an ACS and can mimic symptoms of myocardial infarction with ST-T segments changes on electrocardiography (ECG), a limited release of myocardial enzyme, mainly reported after sudden emotional or physical stress, and an akinesis or dyskinesis of the left ventricle apex which are completely reversible in a few weeks. In the studies included in this review, nuclear medicine techniques have demonstrated a discrepancy between normal perfusion and a reduced glucose utilization in TTC, commonly known as "inverse flow metabolism mismatch". This suggests that apical ballooning represents a transient metabolic disorder on the cellular level, rather than a structural contractile disease of the myocardium, due to a transient decrease of glucose metabolism that might be related to a coronary microcirculation impairment followed by prolonged myocardial stunning. Nuclear medicine techniques can be usefully used for the diagnosis of TTC and can increase our knowledge of the pathophysiological mechanisms of TTC.

  20. Two methods for calculating regional cerebral blood flow from emission computed tomography of inert gas concentrations

    DEFF Research Database (Denmark)

    Kanno, I; Lassen, N A

    1979-01-01

    Two methods are described for calculation of regional cerebral blood flow from completed tomographic data of radioactive inert gas distribution in a slice of brain tissue. It is assumed that the tomographic picture gives the average inert gas concentration in each pixel over data collection perio...... are implemented using synthetic data of xenon-133 emission computed tomography and some of the difficulties likely to be encountered in practice are stressed....

  1. Sodium-22-radiolabeled silica nanoparticles as new radiotracer for biomedical applications: in vivo positron emission tomography imaging, biodistribution, and biocompatibility.

    Science.gov (United States)

    Al Faraj, Achraf; Alotaibi, Basem; Shaik, Abjal Pasha; Shamma, Khaled Z; Al Jammaz, Ibrahim; Gerl, Jürgen

    2015-01-01

    Despite their advantageous chemical properties for nuclear imaging, radioactive sodium-22 ((22)Na) tracers have been excluded for biomedical applications because of their extremely long lifetime. In the current study, we proposed, for the first time, the use of (22)Na radiotracers for pre-clinical applications by efficiently loading with silica nanoparticles (SiNPs) and thus offering a new life for this radiotracer. Crown-ether-conjugated SiNPs (300 nm; -0.18±0.1 mV) were successfully loaded with (22)Na with a loading efficacy of 98.1%±1.4%. Noninvasive positron emission tomography imaging revealed a transient accumulation of (22)Na-loaded SiNPs in the liver and to a lower extent in the spleen, kidneys, and lung. However, the signal gradually decreased in a time-dependent manner to become not detectable starting from 2 weeks postinjection. These observations were confirmed ex vivo by quantifying (22)Na radioactivity using γ-counter and silicon content using inductively coupled plasma-mass spectrometry in the blood and the different organs of interest. Quantification of Si content in the urine and feces revealed that SiNPs accumulated in the organs were cleared from the body within a period of 2 weeks and completely in 1 month. Biocompatibility evaluations performed during the 1-month follow-up study to assess the possibility of synthesized nanocarriers to induce oxidative stress or DNA damage confirmed their safety for pre-clinical applications. (22)Na-loaded nanocarriers can thus provide an innovative diagnostic agent allowing ultra-sensitive positron emission tomography imaging. On the other hand, with its long lifetime, onsite generators or cyclotrons will not be required as (22)Na can be easily stored in the nuclear medicine department and be used on-demand.

  2. {sup 18}F-fluorodeoxyglucose positron emission tomography-computed tomography in the management of adult multisystem Langerhans cell histiocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Obert, Julie [Universite Paris Diderot, Paris (France); Assistance Publique-Hopitaux de Paris, Centre National de Reference de l' Histiocytose Langerhansienne, Service de Pneumologie, Hopital Saint-Louis, Paris (France); Vercellino, Laetitia [Assistance Publique-Hopitaux de Paris, Service de Medecine Nucleaire, Hopital Saint-Louis, Paris (France); Van der Gucht, Axel [Universite Paris Diderot, Paris (France); Assistance Publique-Hopitaux de Paris, Service de Medecine Nucleaire, Hopital Saint-Louis, Paris (France); De Margerie-Mellon, Constance [Universite Paris Diderot, Paris (France); Assistance Publique-Hopitaux de Paris, Service de Radiologie, Hopital Saint-Louis, Paris (France); Bugnet, Emmanuelle; Lorillon, Gwenael [Assistance Publique-Hopitaux de Paris, Centre National de Reference de l' Histiocytose Langerhansienne, Service de Pneumologie, Hopital Saint-Louis, Paris (France); Chevret, Sylvie [Universite Paris Diderot, Paris (France); Assistance Publique-Hopitaux de Paris, Service de Biostatistique et Information Medicale, Hopital Saint-Louis, Paris (France); Biostatistics and Clinical Epidemiology Research Team, U1153 CRESS, Paris (France); Tazi, Abdellatif [Universite Paris Diderot, Paris (France); Assistance Publique-Hopitaux de Paris, Centre National de Reference de l' Histiocytose Langerhansienne, Service de Pneumologie, Hopital Saint-Louis, Paris (France); Biostatistics and Clinical Epidemiology Research Team, U1153 CRESS, Paris (France)

    2017-04-15

    The standard evaluation of multisystem Langerhans cell histiocytosis (LCH) includes a clinical evaluation, laboratory tests and a skeleton/skull X-ray survey, with chest high-resolution computed tomography (HRCT) in the case of pulmonary involvement. Preliminary reports suggest that {sup 18}F-fluorodeoxyglucose positron emission tomography-computed tomography ({sup 18}F-FDG PET-CT) may be useful for evaluating patients with LCH. Fourteen consecutive adult patients with multisystem LCH were included in this retrospective study, and were evaluated using standard procedures and {sup 18}F-FDG PET-CT. The two sets of findings were compared both at baseline and during follow-up. Serial HRCT and pulmonary function tests were used to evaluate outcome in patients with lung involvement. At the baseline evaluation, PET-CT identified every LCH localization found with the standard evaluation (except a mild cecum infiltration). PET-CT showed additional lesions in seven patients, mostly involving bones, and differentiated inactive from active lesions. Thyroid {sup 18}F-FDG uptake was identified in three cases. No pituitary stalk {sup 18}F-FDG uptake was observed in patients with pituitary LCH. Only 3/12 (25 %) patients with pulmonary LCH displayed moderate pulmonary {sup 18}F-FDG uptake. During follow-up, variations (≥50 % of maximum standardized uptake) in bone {sup 18}F-FDG uptake intensity were correlated with disease state and response to treatment. The absence of lung {sup 18}F-FDG uptake did not preclude lung function improvement after treatment. Except for cases with pulmonary and pituitary involvement, {sup 18}F-FDG PET-CT could replace the standard evaluation for staging of adult patients with multisystem LCH. Serial PET-CT scans are useful for evaluating treatment responses, particularly in cases with bone LCH involvement. (orig.)

  3. Effect of tissue heterogeneity on quantification in positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blomqvist, G. [Dept. of Clinical Neuroscience, Experimental Alcohol and Drug Addiction Research Section, Karolinska Hospital, Stockholm (Sweden); Lammertsma, A.A. [PET Methodology Group, Cyclotron Unit, MRC Clinical Sciences Centre, Royal Postgraduate Medical School, Hammersmith Hospital, London (United Kingdom); Mazoyer, B. [Service Hospitalier Frederic Joliot CEA/Dept. de Biologie, Hopital d`Orsay and Antenne d`Informatique Medicale, Hopital Robert Debre, Paris (France); Wienhard, K. [Max-Planck-Inst. fuer Neurologische Forschung, Koeln (Germany)

    1995-07-01

    As a result of the limited spatial resolution of positron emission tomographic scanners, the measurements of physiological parameters are compromised by tissue heterogeneity. The effect of tissue heterogeneity on a number of parameters was studied by simulation and an analytical method. Five common tracer models were assessed. The input and tissue response functions were assumed to be free from noise and systematic errors. The kinetic model was assumed to be perfect. Two components with different kinetics were mixed in different proportions and contrast with respect to the model parameters. Different experimental protocols were investigated. Of three methods investigated for the measurement of cerebral blood flow (CBF) (steady state, dynamic, integral), the second one was least sensitive to errors caused by tissue heterogeneity and the main effect was an underestimation of the distribution volume. With the steady state method, errors in oxygen extraction fraction caused by tissue heterogeneity were always found to be less than the corresponding errors in CBF. For myocardial blood flow the steady state method was found to perform better than the bolus method. The net accumulation of substrate (i.e. rCMR{sub glc} in the case of glucose analogs) was found to be comparatively insensitive to tissue heterogeneity. Individual rate constans such as k{sub 2} and k{sub 3} for efflux and metabolism of the substrate in the pool of unmetabolized substrate in the tissue, respectively, were found to be more sensitive. In studies of radioligand binding, using only tracer doses, the effect of tissue heterogeneity on the parameter k{sub on}.B{sub max} could be considerable. In studies of radioligand binding using a protocol with two experiments, one with high and one with low specific activity, B{sub max} was found to be insensitive while K{sub d} was very sensitive to tissue heterogeneity. (orig.)

  4. Brady-tachycardia syndrome after radiotherapy for lung cancer. Assessment by computed tomography and carbon-11 methionine positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Takuya; Michihata, Tetsuo; Katagiri, Takashi [Showa Univ., Tokyo (Japan). School of Medicine; Okazaki, Osamu; Izumo, Kazuhide; Harumi, Kenichi

    1999-09-01

    A 74-year-old male who had received radiotherapy (total 54 Gy) for right lung cancer 7 months earlier developed a symptomatic brady-tachycardia syndrome requiring the implantation of a permanent pacemaker. Chest CT showed a pulmonary tumor of 2-cm diameter in the right lower lobe with direct extension into the surrounding tissue, suggesting the possibility of cardiac invasion. Carbon-11 methionine positron emission tomography (PET) indicated the absence of visible invasion of the heart with lung cancer. The brady-tachycardia syndrome, therefore, was considered to be associated with sinus node injury due to radiation. Carbon-11 methionine PET metabolic imaging might play an important role in evaluating noninvasively the cause of the arrhythmia in this patient. (author)

  5. Multiaxial tomography of heart chambers by gated blood-pool emission computed tomography using a rotating gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Tamaki, N.; Mukai, T.; Ishii, Y.; Yonekura, Y.; Yamamoto, K.; Kadota, K.; Kambara, H.; Kawai, C.; Torizuka, K.

    1983-05-01

    Fifteen patients and three volunteers underwent radionuclide blood-pool cardiac studies with electrocardiographic gating. Following conventional planar-gated imaging (anterior and left anterior oblique projections), emission computed tomography (ECT), using a rotating gamma camera, was performed.A series of transaxial tomograms of the cardiac chambers was obtained. The left ventricular short-axis plane, long-axis plane, and four-chamber-view plane were then reorganized; each chamber was visualized separately. Compared to gated planar imaging, this technique showed regional asynergy more clearly in patients with myocardial infarction and demonstrated dilatation of the atria and ventricles more accurately in patients with an atrial septal defect and valvular heart diseases. In addition, when a section of the heart is otained at any angle with gated blood pool ECT, three-dimensional assessment of cardiac chambers in motion is more precise; mutual superimposition becomes unnecessary.

  6. A comparison of endoscopic ultrasound guided biopsy and positron emission tomography with integrated computed tomography in lung cancer staging

    DEFF Research Database (Denmark)

    Larsen, S S; Vilmann, P; Krasnik, K

    2009-01-01

    -stage ≥ IIIA(N2), corresponding to T4- and/or N2-N3- and/or M1 disease. Diagnostic values of PET/CT and EUS-FNA, with regard to the diagnosis of advanced lung cancer, were assessed and compared. RESULTS: The sensitivity of PET/CT and EUS-FNA were respectively 60% and 60% for T4 disease, 56% versus 100% for N2......BACKGROUND AND STUDY AIMS: Exact staging of patients with non-small-cell lung cancer (NSCLC) is important to improve selection of resectable and curable patients for surgery. Positron emission tomography with integrated computed tomography (PET/CT) and endoscopic ultrasound guided fine needle...... aspiration biopsy (EUS-FNA) are new and promising methods, but indications in lung cancer staging are controversial. Only few studies have compared the 2 methods. The aim of this study was to assess and compare the diagnostic values of PET/CT and EUS-FNA for diagnosing advanced lung cancer in patients, who...

  7. A Comparison of Endoscopic Ultrasound Guided Biopsy and Positron Emission Tomography with Integrated Computed Tomography in Lung Cancer Staging

    DEFF Research Database (Denmark)

    Larsen, Stine Schmidt; Vilmann, P; Krasnik, K

    2009-01-01

    -stage ≥ IIIA(N2), corresponding to T4- and/or N2-N3- and/or M1 disease. Diagnostic values of PET/CT and EUS-FNA, with regard to the diagnosis of advanced lung cancer, were assessed and compared. RESULTS: The sensitivity of PET/CT and EUS-FNA were respectively 60% and 60% for T4 disease, 56% versus 100% for N2......BACKGROUND AND STUDY AIMS: Exact staging of patients with non-small-cell lung cancer (NSCLC) is important to improve selection of resectable and curable patients for surgery. Positron emission tomography with integrated computed tomography (PET/CT) and endoscopic ultrasound guided fine needle...... aspiration biopsy (EUS-FNA) are new and promising methods, but indications in lung cancer staging are controversial. Only few studies have compared the 2 methods. The aim of this study was to assess and compare the diagnostic values of PET/CT and EUS-FNA for diagnosing advanced lung cancer in patients, who...

  8. Kikuchi-Fujimoto disease mimicking tuberculous lymphadenitis or lymphoma on fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography

    Directory of Open Access Journals (Sweden)

    Abdul Rahim N

    2016-07-01

    Full Text Available Noraini Abdul Rahim,1 Abdul Jalil Nordin,2 Chiara Rusconi,3 Cristina Gabutti,3 Erika Ravelli,4 Claudio Rossetti5 1Diagnostic Imaging Department, Serdang Hospital, Selangor, 2Centre for Diagnostic Nuclear Imaging, University Putra Malaysia, Serdang, Malaysia; 3Department of Haematology, Ospedale Niguarda, Milan, 4Unit of Haematology, Valduce Hospital, Como, 5Department of Advance Technology (Nuclear Medicine, Ospedale Niguarda, Milan, Italy Abstract: Kikuchi-Fujimoto disease, also known as histiocytic lymphadenitis is a rare and benign disease characterized by regional cervical lymphadenopathy with fever of unknown origin, affecting mainly young women. We describe a case of a young Asian female who was initially misdiagnosed as having tuberculous lymphadenitis because of multiple lymphadenopathies with 18-fluorodeoxyglucose uptake on positron emission tomography/computed tomography. Final histologic diagnosis of Kikuchi-Fujimoto disease was made after excisional biopsy of the affected lymph node. The cervical lymphadenopathy has reduced in size and lung lesions disappeared after 2 months without specific treatment. Keywords: cervical lymphadenopathy, Kikuchi disease, PET/CT features

  9. Corrected coronary opacification decrease from coronary computed tomography angiography: Validation with quantitative 13N-ammonia positron emission tomography.

    Science.gov (United States)

    Benz, Dominik C; Gräni, Christoph; Ferro, Paola; Neumeier, Luis; Messerli, Michael; Possner, Mathias; Clerc, Olivier F; Gebhard, Catherine; Gaemperli, Oliver; Pazhenkottil, Aju P; Kaufmann, Philipp A; Buechel, Ronny R

    2017-07-06

    To assess the functional relevance of a coronary artery stenosis, corrected coronary opacification (CCO) decrease derived from coronary computed tomography angiography (CCTA) has been proposed. The present study aims at validating CCO decrease with quantitative 13N-ammonia positron emission tomography (PET) myocardial perfusion imaging (MPI). This retrospective study consists of 39 patients who underwent hybrid CCTA/PET-MPI. From CCTA, attenuation in the coronary lumen was measured before and after a stenosis and corrected to the aorta to calculate CCO and its decrease. Relative flow reserve (RFR) was calculated by dividing the stress myocardial blood flow (MBF) of a vessel territory subtended by a stenotic coronary by the stress MBF of the reference territories without stenoses. RFR was abnormal in 11 vessel territories (27%). CCO decrease yielded a sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for prediction of an abnormal RFR of 73%, 70%, 88%, 47%, and 70%, respectively. CCTA-derived CCO decrease has moderate diagnostic accuracy to predict an abnormal RFR in PET-MPI. However, its high negative predictive value to rule out functional relevance of a given lesion may confer clinical implications in the diagnostic work-up of patients with a coronary stenosis.

  10. Preoperative [18]fluorodeoxyglucose-positron emission tomography/computed tomography in early stage breast cancer: Rates of distant metastases.

    Science.gov (United States)

    Vinh-Hung, Vincent; Everaert, Hendrik; Farid, Karim; Djassemi, Navid; Baudin-Veronique, Jacqueline; Bougas, Stefanos; Michailovich, Yuriy; Joachim-Contaret, Clarisse; Cécilia-Joseph, Elsa; Verschraegen, Claire; Nguyen, Nam P

    2017-07-28

    To investigate rates of distant metastases (DM) detected with [18]fluorodeoxyglucose-positron emission tomography/computed tomography (18FDG-PET/CT) in early stage invasive breast cancer. We searched the English language literature databases of PubMed, EMBASE, ISI Web of Knowledge, Web of Science and Google Scholar, for publications on DM detected in patients who had 18FDG-PET/CT scans as part of the staging for early stages of breast cancer (stage I and II), prior to or immediately following surgery. Reports published between 2011 and 2017 were considered. The systematic review was conducted according to the PRISMA guidelines. Among the 18 total studies included in the analysis, the risk of DM ranged from 0% to 8.3% and 0% to 12.9% for stage I and II invasive breast cancer, respectively. Among the patients with clinical stage II, the rate of occult metastases diagnosed by 18FDG-PET/CT was 7.2% (range, 0%-19.6%) for stage IIA and 15.8% (range, 0%-40.8%) for stage IIB. In young patients (< 40-year-old), 18FDG-PET/CT demonstrated a higher prevalence of DM at the time of diagnosis for those with aggressive histology (i.e., triple-negative receptors and poorly differentiated grade). Young patients with poorly differentiated tumors and stage IIB triple-negative breast cancer may benefit from 18FDG-PET/CT at initial staging to detect occult DM prior to surgery.

  11. Scar imaging using multislice computed tomography versus metabolic imaging by F-18 FDG positron emission tomography: a pilot study.

    Science.gov (United States)

    Dwivedi, Girish; Al-Shehri, Halia; deKemp, Robert A; Ali, Iftikhar; Alghamdi, Abdul Aziz; Klein, Ran; Scullion, Andrew; Ruddy, Terrence D; Beanlands, Rob S; Chow, Benjamin J W

    2013-09-30

    F-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) FDG PET is an established metabolic imaging technique to assess myocardial viability. Delayed iodinated contrast enhancement (DE) of myocardium on computed tomography (CT) has also been shown to be an anatomical marker of nonviable myocardium. A pilot study was undertaken to determine quantitative and qualitative agreement between metabolic viability imaging and scar imaging using FDG PET and multislice CT respectively. Fifteen patients with coronary artery disease and left ventricular dysfunction were recruited in the study. All patients underwent same day FDG PET and DECT to evaluate myocardial viability. The images were analyzed quantitatively and qualitatively using a 17 segment model. DECT diagnosed viability in 57% (146/255) whilst PET in 51% (129/255) of segments. The per-segment agreement between DECT and FDG PET on qualitative analysis was 70% (Kappa: 0.40). The agreement in quantitative measurements between the two techniques for viability showed modest correlation [Pearson ρ: 0.63; Pcorrelate modestly with metabolic FDG PET, both qualitatively and quantitatively. Although in our study quantitative analysis offered superior agreement compared to qualitative with DECT, further studies are needed to determine its incremental value. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  12. Lymphadenopathy resulting from acute toxoplasmosis mimicking relapse of non-Hodgkin's lymphoma on fluorodeoxyglucose positron emission tomography/computed tomography.

    Science.gov (United States)

    Joshi, Prathamesh; Lele, Vikram; Mahajan, Pravin

    2012-01-01

    We report a case documenting fluorodeoxyglucose (FDG) accumulation in cervical, supraclavicular and axillary lymph nodes resulting from acute toxoplasmosis. A 50-year-old Indian female with history of non-Hodgkin's lymphoma (NHL) of left breast, postchemotherapy status, was found to have hypermetabolic right cervical, supraclavicular and axillary lymph nodes on a surveillance FDG positron emission tomography/computed tomography (PET/CT) scan. Her previous two PET/CT scans were unremarkable with no evidence of metabolically active disease. Therefore, a differential diagnosis of relapse of NHL versus infectious/inflammatory pathology was raised in the report. Biopsy of axillary lymph node demonstrated features characteristic of toxoplasmosis. The serological test results were also compatible with acute toxoplasmosis infection. Infective and inflammatory diseases are known to accumulate FDG, resulting in false positives for malignancy. This case demonstrates lymph nodal toxoplasmosis as a potential cause of false positive FDG PET/CT findings in patients with known malignancy and highlights the importance of histopathological and laboratory correlation for the accurate interpretation of FDG PET/CT scans.

  13. [Positron emission tomography combined with computed tomography in the initial evaluation and response assessment in primary central nervous system lymphoma].

    Science.gov (United States)

    Mercadal, Santiago; Cortés-Romera, Montserrat; Vélez, Patricia; Climent, Fina; Gámez, Cristina; González-Barca, Eva

    2015-06-08

    To evaluate the role of positron emission tomography combined with computed tomography (PET-CT) in the initial evaluation and response assessment in primary central nervous system lymphoma (PCNSL). Fourteen patients (8 males) with a median age 59.5 years diagnosed of PCNSL. A brain PET-CT and magnetic resonance imaging (MRI) were performed in the initial evaluation. In 7 patients a PET-CT after treatment was performed. PET-CT showed at diagnosis 31 hypermetabolic focuses and MRI showed 47 lesions, with a good grade of concordance between both (k = 0.61; P = .005). In the response assessment, correlation between both techniques was good, and PET-CT was helpful in the appreciation of residual MRI lesions. Overall survival at 2 years of negative vs. positive PET-CT at the end of treatment was 100 vs. 37.5%, respectively (P = .045). PET-CT can be useful in the initial evaluation of PCNSL, and especially in the assessment of response. Despite the fact that PET-CT detects less small lesions than MRI, a good correlation between MRI and PET-CT was observed. It is effective in the evaluation of residual lesions. Prospective studies are needed to confirm their possible prognostic value. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  14. Technetium-99m Methylene Diphosphonate Single-photon Emission Computed Tomography/Computed Tomography of the Foot and Ankle.

    Science.gov (United States)

    Upadhyay, Bhavin; Mo, Jonathan; Beadsmoore, Clare; Marshall, Tom; Toms, Andoni; Buscombe, John

    2017-01-01

    The complex anatomy and function of the foot and ankle can make it difficult to determine the cause of symptoms in patients with foot and ankle pathology. Following initial clinical and radiographic assessment, additional imaging with magnetic resonance imaging may be required, which is often seen as the modality of choice. Although sensitive to pathological changes in bone metabolism and vascularity, technetium-99m (Tc-99m) bone scintigraphy often lacks the specificity and resolution required to evaluate the structures of the foot and ankle. Tc-99m methylene diphosphonate single-photon emission computed tomography/computed tomography (SPECT/CT) combines this sensitivity with the superior anatomical detail of CT, enabling better localization of pathological uptake and evaluation of associated structural changes. As a result, SPECT/CT has been growing in popularity for the assessment of patients with foot and ankle pathology where it can provide additional information that may change the initial diagnosis and subsequent management plan. Studies have reported modification of the surgical approach and site of intra-articular local anesthetic injections following SPECT/CT with good results. Interpretation of SPECT/CT studies requires an understanding of the pathological changes that result in increased tracer accumulation in addition to the CT changes that may be seen. This review aims to highlight the advantages of SPECT/CT, potential applications and explain the imaging appearances of common pathologies that may be observed.

  15. Development of a Simple Image Processing Application that Makes Abdominopelvic Tumor Visible on Positron Emission Tomography/Computed Tomography Image.

    Science.gov (United States)

    Pandey, Anil Kumar; Saroha, Kartik; Sharma, Param Dev; Patel, Chetan; Bal, Chandrashekhar; Kumar, Rakesh

    2017-01-01

    In this study, we have developed a simple image processing application in MATLAB that uses suprathreshold stochastic resonance (SSR) and helps the user to visualize abdominopelvic tumor on the exported prediuretic positron emission tomography/computed tomography (PET/CT) images. A brainstorming session was conducted for requirement analysis for the program. It was decided that program should load the screen captured PET/CT images and then produces output images in a window with a slider control that should enable the user to view the best image that visualizes the tumor, if present. The program was implemented on personal computer using Microsoft Windows and MATLAB R2013b. The program has option for the user to select the input image. For the selected image, it displays output images generated using SSR in a separate window having a slider control. The slider control enables the user to view images and select one which seems to provide the best visualization of the area(s) of interest. The developed application enables the user to select, process, and view output images in the process of utilizing SSR to detect the presence of abdominopelvic tumor on prediuretic PET/CT image.

  16. The Medical Case for a Positron Emission Tomography and X-ray Computed Tomography Combined Service in Oman.

    Science.gov (United States)

    Al-Bulushi, Naima K; Bailey, Dale; Mariani, Giuliano

    2013-11-01

    The value of a positron emission tomography and X-ray computed tomography (PET/CT) combined service in terms of diagnostic accuracy, cost-effectiveness and impact on clinical decision-making is well-documented in the literature. Its role in the management of patients presenting with cancer is shifting from early staging and restaging to the early assessment of the treatment response. Currently, the application of PET/CT has extended to non-oncological specialties-mainly neurology, cardiology and rheumatology. A further emerging application for PET/CT is the imaging of infection/inflammation. This article illustrates some of the PET/CT applications in both oncological and non-oncological disorders. In view of the absence of this modality in Oman, this article aims to increase the awareness of the importance of these imaging modalities and their significant impact on diagnosis and management in both oncological and non-oncological specialties for patients of all age groups as well as the decision-makers.

  17. Clinico-radiological correlation of Wilson's disease by magnetic resonance imaging, computed tomography and positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Ken; Sakata, Chigusa; Nemoto, Hiroshi; Yokoi, Fuji; Sunohara, Nobuhiko (National Center of Neurology and Psychiatry, Kodaira, Tokyo (Japan)); Iio, Masaaki

    1991-02-01

    Five patients with Wilson's disease received repeated magnetic resonance imaging (MRI) and computed tomography (CT) examinations at intervals from 6 to 29 months. Four patients, except for asymptomatic one, also underwent positron emission tomography (PET). The significance and limitations of these imaging modalities were examined in the light of their correlation with clinical manifestations and their therapeutic evaluation. The following focal regions, detected on MRI, had a strong positive correlation with clinical manifestations: the lenticular nuclei for dystonia, the brain stem for abnormality of smooth persuit eye movements, and the caudate and lenticular nuclei for severe dysarthria/dysphagia. Follow-up MRI for 3 patients showed an improvement of findings in the lenticular nuclei, lateral part of the putamen, and brain stem, that was in accordance with improved clinical or neurologic manifestations, such as dystonia and cerebellar symptoms. Severe abnormality in the caudate nucleus was associated with poor prognosis. Repeated CT failed to show serial changes in any of the patients. Regional blood flow and oxygen metabolic rate, obtained by PET examinations, were slightly decreased in the thalamus that had normal findings on both MRI and CT, as well as in the cerebral cortex and basal ganglia. PET was, however, inferior to MRI in detecting fine foci within the basal ganglia. In conclusion, there was a good correlation between MRI findings, particularly foci of the caudate and lenticular nuclei, and clinical manifestations. Repeated MRI examinations were the most useful approach to the evaluation of therapeutic effects and prognosis. (N.K.).

  18. Positron emission tomography-computed tomography in the diagnostic evaluation of smoldering multiple myeloma: identification of patients needing therapy.

    Science.gov (United States)

    Siontis, B; Kumar, S; Dispenzieri, A; Drake, M T; Lacy, M Q; Buadi, F; Dingli, D; Kapoor, P; Gonsalves, W; Gertz, M A; Rajkumar, S V

    2015-10-23

    We studied 188 patients with a suspected smoldering multiple myeloma (MM) who had undergone a positron emission tomography-computed tomography (PET-CT) scan as part of their clinical evaluation. PET-CT was positive (clinical radiologist interpretation of increased bone uptake and/or evidence of lytic bone destruction) in 74 patients and negative in 114 patients. Of these, 25 patients with a positive PET-CT and 97 patients with a negative PET-CT were observed without therapy and formed the study cohort (n=122). The probability of progression to MM within 2 years was 75% in patients with a positive PET-CT observed without therapy compared with 30% in patients with a negative PET-CT; median time to progression was 21 months versus 60 months, respectively, P=0.0008. Of 25 patients with a positive PET-CT, the probability of progression was 87% at 2 years in those with evidence of underlying osteolysis (n=16) and 61% in patients with abnormal PET-CT uptake but no evidence of osteolysis (n=9). Patients with positive PET-CT and evidence of underlying osteolysis have a high risk of progression to MM within 2 years when observed without therapy. These observations support recent changes to imaging requirements in the International Myeloma Working Group updated diagnostic criteria for MM.

  19. The utility of (68)Ga-DOTATATE positron-emission tomography/computed tomography in the diagnosis, management, follow-up and prognosis of neuroendocrine tumors.

    Science.gov (United States)

    Tirosh, Amit; Kebebew, Electron

    2017-10-26

    Neuroendocrine tumors (NETs) are rare neoplasms that emerge mainly from the GI tract, pancreas and respiratory tract. The incidence of NETs has increased more than sixfold in the last decades. NETs typically express somatostatin receptors on their cell surface, which can be targeted by 'cold' somatostatin analogs for therapy or by 'hot' radiolabeled somatostatin analogs for tumor localization and treatment. 68-Gallium-DOTA peptides (DOTATATE, DOTATOC, DOTANOC) positron emission tomography/computed tomography is a highly accurate imaging modality for NETs that has been found to be more sensitive for NET detection than other imaging modalities. In the current review, we will discuss the clinical utility of 68-Gallium-DOTATATE positron emission tomography/computed tomography for the diagnosis and management of patients with NETs.

  20. Combined use of positron emission tomography and volume doubling time in lung cancer screening with low-dose CT scanning

    DEFF Research Database (Denmark)

    Ashraf, H; Dirksen, A; Jakobsen, Annika Loft

    2011-01-01

    In lung cancer screening the ability to distinguish malignant from benign nodules is a key issue. This study evaluates the ability of positron emission tomography (PET) and volume doubling time (VDT) to discriminate between benign and malignant nodules....

  1. Cost Effectiveness of Positron Emission Tomography for the Management of Potentially Operable Non-Small Cell Lung Cancer in Quebec

    Directory of Open Access Journals (Sweden)

    Van Hung Nguyen

    2005-01-01

    Full Text Available BACKGROUND: The potential benefits of positron emission tomography (PET scanning stem from the fact that it can reduce the number of diagnostic examinations; particularly, the number of unnecessary thoracic surgeries.

  2. Monolithic LaBr3 : Ce crystals on silicon photomultiplier arrays for time-of-flight positron emission tomography

    NARCIS (Netherlands)

    Seifert, Stefan; van Dam, Herman T.; Huizenga, Jan; Vinke, Ruud; Dendooven, Peter; Löhner, Herbert; Schaart, Dennis R.

    2012-01-01

    Positron emission tomography detectors based on monolithic scintillation crystals exhibit good spatial and energy resolution, intrinsically provide depth-of-interaction information, have high gamma-photon capture efficiency, and may reduce the manufacturing costs compared to pixelated crystal

  3. Changes in 18F-Fluorodeoxyglucose Uptake in the Spinal Cord in a Healthy Population on Serial Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Chong, Ari; Song, Ho-Chun; Byun, Byung-Hyun; Hong, Sun-Pyo; Min, Jung-Joon; Bom, Hee-Seung; Ha, Jung-Min; Lee, Jung-Kil

    2013-01-01

    We aimed to determine the changes in 18F-fluorodeoxyglucose (FDG) uptake in the spinal cord on two serial positron emission tomography/computed tomography (PET/CT) scans in a healthy population. We retrospectively enrolled healthy people who underwent PET/CT twice for cancer screening. We excluded those who had degenerative vertebral disease, neurologic disease, or a history of a vertebral operation. The standardized uptake value (SUVmax) of the spinal cord of each mid-vertebral body was obta...

  4. Lymphadenopathy resulting from acute toxoplasmosis mimicking relapse of non-Hodgkin′s lymphoma on fluorodeoxyglucose positron emission tomography/computed tomography

    OpenAIRE

    Prathamesh Joshi; Vikram Lele; Pravin Mahajan

    2012-01-01

    We report a case documenting fluorodeoxyglucose (FDG) accumulation in cervical, supraclavicular and axillary lymph nodes resulting from acute toxoplasmosis. A 50-year-old Indian female with history of non-Hodgkin′s lymphoma (NHL) of left breast, postchemotherapy status, was found to have hypermetabolic right cervical, supraclavicular and axillary lymph nodes on a surveillance FDG positron emission tomography/computed tomography (PET/CT) scan. Her previous two PET/CT scans were unremarkable wi...

  5. The Rate and Clinical Significance of Incidental Thyroid Uptake as Detected by Gallium-68 DOTATATE Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Nockel, Pavel; Millo, Corina; Keutgen, Xavier; Klubo-Gwiezdzinska, Joanna; Shell, Jasmine; Patel, Dhaval; Nilubol, Naris; Herscovitch, Peter; Sadowski, Samira M.; Kebebew, Electron

    2016-01-01

    Background: Gallium-68 (Ga-68) DOTATATE is a radiolabeled peptide���imaging modality that targets the somatostatin receptor (SSTR), especially subtype 2 (SSTR2). Benign and malignant thyroid tumors have been observed to express SSTR. The aim of this study was to evaluate the frequency and clinical significance of incidental atypical thyroid uptake as detected by Ga-68 DOTATATE positron emission tomography/computed tomography (PET/CT).

  6. Ga-68 DOTATATE positron emission tomography/computer tomography in initial staging and therapy response evaluation in a rare case of primary neuroblastoma in neck.

    Science.gov (United States)

    Agrawal, Kanhaiyalal; Kumar, Ritesh; Shukla, Jaya; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2014-07-01

    Gallium-68 (Ga-68) DOTA-peptide positron emission tomography/computer tomography (PET/CT) has higher sensitivity and improved spatial resolution for the detection of somatostatin receptor expressing tumors than conventional somatostatin receptor scintigraphy. We present the findings of Ga-68 DOTATATE PET/CT in a rare case of primary neuroblastoma of the neck in a 12-year-old female child and its role in the evaluation of the treatment response.

  7. Gallium-68 DOTA-TATE Positron Emission Tomography/Computed Tomography: Scintigraphic Changes of Adrenal Glands Following Management of Ectopic Cushing's Syndrome by Steroidogenesis Inhibitors

    OpenAIRE

    Huang, Yu-Ting; Aziz, Shaikh Irfan; Kumar, Aravind S. Ravi

    2014-01-01

    In the era of emerging functional imaging techniques, an understanding of the effects of hormonal therapies on the scintigraphic appearance of endocrine organs is desirable to minimize the erroneous scan interpretation. The mechanisms by which changes in the scintigraphic appearance of endocrine organs occur however sometimes remain ambiguous. This case demonstrates the gallium-68 (Ga-68) DOTA-TATE positron emission tomography/computed tomography (CT) appearance of adrenal glands following ma...

  8. Ga-68 DOTATATE positron emission tomography/computer tomography in initial staging and therapy response evaluation in a rare case of primary neuroblastoma in neck

    OpenAIRE

    Agrawal, Kanhaiyalal; Kumar, Ritesh; Shukla, Jaya; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2014-01-01

    Gallium-68 (Ga-68) DOTA-peptide positron emission tomography/computer tomography (PET/CT) has higher sensitivity and improved spatial resolution for the detection of somatostatin receptor expressing tumors than conventional somatostatin receptor scintigraphy. We present the findings of Ga-68 DOTATATE PET/CT in a rare case of primary neuroblastoma of the neck in a 12-year-old female child and its role in the evaluation of the treatment response.

  9. Rare case of isolated splenic metastases from gastric cancer detected with fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography.

    Science.gov (United States)

    Kamaleshwaran, Koramadai Karuppusamy; Sivanesan, Balasubramanian; Shibu, Deepu; Shinto, Ajit Sugunan

    2013-04-01

    We report a rare case of isolated splenic metastasis from gastric cancer detected with fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography (PET/CT). A 55-year-old man with gastric cancer 1 year post surgery, evaluated with PET/CT showed focal, intense uptake in the spleen, with no other abnormal findings. On splenectomy, the lesion was confirmed as metastasis from gastric cancer pathologically.

  10. Penile Metastasis from Prostate Cancer Presenting as Malignant Priapism Detected Using Gallium-68 Prostate-specific Membrane Antigen Positron Emission Tomography/Computed Tomography.

    Science.gov (United States)

    Kamaleshwaran, Koramadai Karuppusamy; Balasundararaj, Barani Kumar Pollachi; Jose, Raghi; Shinto, Ajit Sugunan

    2018-01-01

    Gallium-68 prostate-specific membrane antigen positron emission tomography/computed tomography (Ga-68 PSMA PET/CT) is a promising diagnostic tool for patients with prostate cancer. Penile metastasis from prostate cancer is a rare phenomenon that infrequently manifests as malignant priapism. We present a case of 79-year-old patient diagnosed as a case of adenocarcinoma prostate presenting with penile metastases imaged using Ga-68 PSMA PET/CT.

  11. Combined use of positron emission tomography and volume doubling time in lung cancer screening with low-dose CT scanning

    DEFF Research Database (Denmark)

    Ashraf, H; Dirksen, A; Jakobsen, Annika Loft

    2011-01-01

    In lung cancer screening the ability to distinguish malignant from benign nodules is a key issue. This study evaluates the ability of positron emission tomography (PET) and volume doubling time (VDT) to discriminate between benign and malignant nodules.......In lung cancer screening the ability to distinguish malignant from benign nodules is a key issue. This study evaluates the ability of positron emission tomography (PET) and volume doubling time (VDT) to discriminate between benign and malignant nodules....

  12. The contribution of single photon emission computed tomography in the clinical assessment of Alzheimer type dementia; Apport de la tomographie d'emission monophonique cerebrale dans l'evaluation des demences de type Alzheimer

    Energy Technology Data Exchange (ETDEWEB)

    Boudousq, V.; Collombier, L.; Kotzki, P.O. [Centre Hospitalier Universitaire de Nimes, 30 (France)

    1999-12-01

    Interest of brain single-photon emission computed tomography to support clinical diagnosis of Alzheimer-type dementia is now established. Numerous studies have reported a decreased perfusion in the association cortex of the parietal lobe and the posterior temporal regions. In patients with mild cognitive complaints, the presence of focal hypoperfusion may increase substantially the probability of the disease. In addition, emission tomography emerges as a helpful tool in situation in which there is diagnostic doubt. In this case, the presence of temporo-parietal perfusion deficit associated with hippocampal atrophy on MRI or X-ray computed tomography contributes to diagnostic accuracy. However, some studies suggest that emission tomography may be useful for preclinical prediction of Alzheimer's disease and to predict cognitive decline. (author)

  13. Non-oncological positron emission tomography (PET): brain imaging; La tomographie par emission de positons (TEP) hors oncologie: l'exploration du cerveau

    Energy Technology Data Exchange (ETDEWEB)

    Lomena, F. [Centro de Diagnostico por la imagen (CDIC), Hospital Clinic, Servicio de medicina nuclear, Barcelona (Spain)

    2008-10-15

    Positron emission tomography (PET) allows evaluation of the central nervous system function. Imaging of regional cerebral blood flow and metabolism, and of several neurotransmission systems may be obtained using PET. PET quantification is accurate and has good test-retest reliability. For research purposes, PET has been used to study brain physiology, to explore neurological and psychiatric diseases pathophysiology and for the new drugs research and development. F.D.G. is the only PET radioligand with clinical application. Following criteria of evidence-based medicine, the clinical indications of F.D.G.-PET are: evaluation of treated gliomas, pre surgical study of partial refractory epilepsy and diagnosis of Alzheimer's disease when it is impossible to differentiate clinically from fronto-temporal dementia.

  14. Positron emission tomography in digestive neuroendocrine tumors: choice of the tracer; Apport de la tomographie par emission de positons dans les tumeurs endocrines digestives: choix du traceur

    Energy Technology Data Exchange (ETDEWEB)

    Taieb, D.; Tessonnier, L.; Mundler, O. [Centre Hospitalo-Universitaire de La Timone, Service Central de Biophysique et de Medecine Nucleaire, 13 - Marseille (France)

    2009-11-15

    Digestive endocrine tumors represent a heterogeneous group of neoplasm sharing common characteristics such as their high density of peptide receptors, their ability to take up amino acids and de-carboxylate them into biogenic amines and their low glycolytic activity. These features are used for nuclear imaging targeting. To date, somatostatin receptor scintigraphy is considered the 'gold standard' imaging procedure of well-differentiated tumors. Despite the significant contribution of SPECT/CT, the use of positron emission tomography imaging (PET) is growing rapidly. Three PET imaging modalities are currently available: {sup 68}Ga-labeled somatostatin analogs PET, {sup 18}F-dihydroxy-phenylalanine PET ({sup 18}F-DOPA) and {sup 18}F-deoxyglucose PET ({sup 18}F-F.D.G.). This article focuses on the current targets of molecular imaging and highlights the potential clinical applications of new targets. (authors)

  15. Macrocyclic diamide ligand systems: potential chelators for 64Cu- and 68Ga-based positron emission tomography imaging agents.

    Science.gov (United States)

    Barnard, Peter J; Holland, Jason P; Bayly, Simon R; Wadas, Thaddeus J; Anderson, Carolyn J; Dilworth, Jonathan R

    2009-08-03

    The N(4)-macrocyclic ligand 2,10-dioxo-1,4,8,11-tetraazabicyclo[11.4.0]1,12-heptadeca-1(12),14,16-triene H(2)L has been synthesized by the [1 + 1] condensation reaction between N,N'-bis(chloroacetyl)-1,2-phenylenediamine and 1,3-propylenediamine. The coordination chemistry of this ligand has been investigated with the metal ions Cu(II), Ni(II), Zn(II), and Ga(III) (complexes 1, 2, 3 and 4, respectively). H(2)L and its metal complexes have been fully characterized by the use of NMR, UV/vis, electron paramagnetic resonance, and elemental analysis where appropriate. The four metal complexes 1-4 have been structurally characterized by X-ray crystallography which confirmed that in all cases the amide nitrogen atoms are deprotonated and coordinated to the metal center. Complexes 3 and 4 are five-coordinate with a water molecule and chloride ion occupying the apical site, respectively. Cyclic voltammetric measurements on complex 1 show that this complex is oxidized reversibly with a half-wave potential, E(1/2) = 0.47 V, and reduced irreversibly at E(P) = -1.84 V. Density functional theory calculations reproduce the geometries of the four complexes. The one-electron reduction and oxidation potentials for 1 were calculated by using two solvent models, DMF and H(2)O. The calculations indicated that the one electron oxidation of 1 may involve removal of an electron from the ligand as opposed to the metal center, producing a diradical. The diamide macrocyle is of interest for the development of new positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging agents, and a radiolabeled complex has been synthesized with the positron emitting isotope (64)Cu. In vivo biodistribution studies for the (64)Cu labeled complex, (64)Cu-1, in male Lewis rats, showed that the activity is cleared rapidly from the blood within 1-2 h post-administration.

  16. Absolute quantitation of iodine-123 epidepride kinetics using single-photon emission tomography: comparison with carbon-11 epidepride and positron emission tomography.

    Science.gov (United States)

    Almeida, P; Ribeiro, M J; Bottlaender, M; Loc'h, C; Langer, O; Strul, D; Hugonnard, P; Grangeat, P; Mazière, B; Bendriem, B

    1999-12-01

    Epidepride labelled with iodine-123 is a suitable probe for the in vivo imaging of striatal and extrastriatal dopamine D2 receptors using single-photon emission tomography (SPET). Recently, this molecule has also been labelled with carbon-11. The goal of this work was to develop a method allowing the in vivo quantification of radioactivity uptake in baboon brain using SPET and to validate it using positron emission tomography (PET). SPET studies were performed in Papio anubis baboons using 123I-epidepride. Emission and transmission measurements were acquired on a dual-headed system with variable head angulation and low-energy ultra-high resolution (LEUHR) collimation. The imaging protocol consisted of one transmission measurement (24 min, heads at 90 degrees), obtained with two sliding line sources of gadolinium-153 prior to injection of 0.21-0.46 GBq of 123I-epidepride, and 12 emission measurements starting 5 min post injection. For scatter correction (SC) we used a dual-window method adapted to 123I. Collimator blurring correction (CBC) was done by deconvolution in Fourier space and attenuation correction (AT) was applied on a preliminary (CBC) filtered back-projection reconstruction using 12 iterations of a preconditioned, regularized minimal residual algorithm. For each reconstruction, a calibration factor was derived from a uniform cylinder filled with a 123I solution of a known radioactivity concentration. Calibration and baboon images were systematically built with the same reconstruction parameters. Uncorrected (UNC) and (AT), (SC + AT) and (SC + CBC + AT) corrected images were compared. PET acquisitions using 0.11-0.44 GBq of 11C-epidepride were performed on the same baboons and used as a reference. The radioactive concentrations expressed in percent of the injected dose per 100 ml (% ID/100 ml) obtained after (SC + CBC + AT) in SPET are in good agreement with those obtained with PET and 11C-epidepride. A method for the in vivo absolute quantitation of 123

  17. Crystallization-induced red emission of a facilely synthesized biodegradable indigo derivative.

    Science.gov (United States)

    Yang, Cangjie; Trinh, Quang Thang; Wang, Xiaochen; Tang, Yuxin; Wang, Kai; Huang, Shuo; Chen, Xiaodong; Mushrif, Samir H; Wang, Mingfeng

    2015-02-25

    We report a new class of crystallization-induced red-emitting luminogen based on a synthetic biodegradable indigo derivative, Indigoid-B. This compound, upon an ultrasonic treatment, formed well-defined microcrystals that showed striking crystallization-induced emission (CIE) in mixed solvents of tetrahydrofuran-water.

  18. Comparison of {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography, hydro-stomach computed tomography, and their combination for detecting primary gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Hye Young; Chung, Woo Suk; Song, E Rang; Kim, Jin Suk [Konyang University Myunggok Medical Research Institute, Konyang University Hospital, Konyang University College of Medicine, Daejeon (Korea, Republic of)

    2015-01-15

    To retrospectively compare the diagnostic accuracy for detecting primary gastric cancer on positron emission tomography/computed tomography (PET/CT) and hydro-stomach CT (S-CT) and determine whether the combination of the two techniques improves diagnostic performance. A total of 253 patients with pathologically proven primary gastric cancer underwent PET/CT and S-CT for the preoperative evaluation. Two radiologists independently reviewed the three sets (PET/CT set, S-CT set, and the combined set) of PET/CT and S-CT in a random order. They graded the likelihood for the presence of primary gastric cancer based on a 4-point scale. The diagnostic accuracy of the PET/CT set, the S-CT set, and the combined set were determined by the area under the alternative-free receiver operating characteristic curve, and sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Diagnostic accuracy, sensitivity, and NPV for detecting all gastric cancers and early gastric cancers (EGCs) were significantly higher with the combined set than those with the PET/CT and S-CT sets. Specificity and PPV were significantly higher with the PET/CT set than those with the combined and S-CT set for detecting all gastric cancers and EGCs. The combination of PET/CT and S-CT is more accurate than S-CT alone, particularly for detecting EGCs.

  19. Whole body muscle activity during the FIFA 11+ program evaluated by positron emission tomography.

    Science.gov (United States)

    Nakase, Junsuke; Inaki, Anri; Mochizuki, Takafumi; Toratani, Tatsuhiro; Kosaka, Masahiro; Ohashi, Yoshinori; Taki, Junichi; Yahata, Tetsutaro; Kinuya, Seigo; Tsuchiya, Hiroyuki

    2013-01-01

    This study investigated the effect of the FIFA 11+ warm-up program on whole body muscle activity using positron emission tomography. Ten healthy male volunteers were divided into a control group and a group that performed injury prevention exercises (The 11+). The subjects of the control group were placed in a sitting position for 20 min and 37 MBq of (18)F-fluorodeoxyglucose (FDG) was injected intravenously. The subjects then remained seated for 45 min. The subjects of the exercise group performed part 2 of the 11+for 20 min, after which FDG was injected. They then performed part 2 of the 11+for 20 min, and rested for 25 min in a sitting position. Positron emission tomography-computed tomography images were obtained 50 min after FDG injection in each group. Regions of interest were defined within 30 muscles. The standardized uptake value was calculated to examine the FDG uptake of muscle tissue per unit volume. FDG accumulation within the abdominal rectus, gluteus medius and minimus were significantly higher in the exercise group than in the control group (PFIFA 11+ program.

  20. Whole body muscle activity during the FIFA 11+ program evaluated by positron emission tomography.

    Directory of Open Access Journals (Sweden)

    Junsuke Nakase

    Full Text Available PURPOSE: This study investigated the effect of the FIFA 11+ warm-up program on whole body muscle activity using positron emission tomography. METHODS: Ten healthy male volunteers were divided into a control group and a group that performed injury prevention exercises (The 11+. The subjects of the control group were placed in a sitting position for 20 min and 37 MBq of (18F-fluorodeoxyglucose (FDG was injected intravenously. The subjects then remained seated for 45 min. The subjects of the exercise group performed part 2 of the 11+for 20 min, after which FDG was injected. They then performed part 2 of the 11+for 20 min, and rested for 25 min in a sitting position. Positron emission tomography-computed tomography images were obtained 50 min after FDG injection in each group. Regions of interest were defined within 30 muscles. The standardized uptake value was calculated to examine the FDG uptake of muscle tissue per unit volume. RESULTS: FDG accumulation within the abdominal rectus, gluteus medius and minimus were significantly higher in the exercise group than in the control group (P<0.05. CONCLUSION: The hip abductor muscles and abdominal rectus were active during part 2 of the FIFA 11+ program.

  1. DIRECT OBSERVATION OF SOLAR CORONAL MAGNETIC FIELDS BY VECTOR TOMOGRAPHY OF THE CORONAL EMISSION LINE POLARIZATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Kramar, M. [Physics Department, The Catholic University of America, 620 Michigan Avenue NE, Washington, DC 20064 (United States); Lin, H. [Institute for Astronomy, University of Hawaii at Manoa, 34 Ohia Ku Street, Pukalani, Maui, HI 96768 (United States); Tomczyk, S., E-mail: kramar@cua.edu, E-mail: lin@ifa.hawaii.edu, E-mail: tomczyk@ucar.edu [High Altitude Observatory, 3080 Center Green Drive, Boulder, CO 80301 (United States)

    2016-03-10

    We present the first direct “observation” of the global-scale, 3D coronal magnetic fields of Carrington Rotation (CR) Cycle 2112 using vector tomographic inversion techniques. The vector tomographic inversion uses measurements of the Fe xiii 10747 Å Hanle effect polarization signals by the Coronal Multichannel Polarimeter (CoMP) and 3D coronal density and temperature derived from scalar tomographic inversion of Solar Terrestrial Relations Observatory (STEREO)/Extreme Ultraviolet Imager (EUVI) coronal emission lines (CELs) intensity images as inputs to derive a coronal magnetic field model that best reproduces the observed polarization signals. While independent verifications of the vector tomography results cannot be performed, we compared the tomography inverted coronal magnetic fields with those constructed by magnetohydrodynamic (MHD) simulations based on observed photospheric magnetic fields of CR 2112 and 2113. We found that the MHD model for CR 2112 is qualitatively consistent with the tomography inverted result for most of the reconstruction domain except for several regions. Particularly, for one of the most noticeable regions, we found that the MHD simulation for CR 2113 predicted a model that more closely resembles the vector tomography inverted magnetic fields. In another case, our tomographic reconstruction predicted an open magnetic field at a region where a coronal hole can be seen directly from a STEREO-B/EUVI image. We discuss the utilities and limitations of the tomographic inversion technique, and present ideas for future developments.

  2. Diagnostic performance of unenhanced computed tomography and 18 F-fluorodeoxyglucose positron emission tomography in indeterminate adrenal tumours.

    Science.gov (United States)

    Delivanis, Danae A; Bancos, Irina; Atwell, Thomas D; Schmit, Grant D; Eiken, Patrick W; Natt, Neena; Erickson, Dana; Maraka, Spyridoula; Young, William F; Nathan, Mark A

    2018-01-01

    Evidence on the diagnostic performance of adrenal imaging is limited. We aimed to assess the diagnostic performance of unenhanced computed tomography (CT) and 18 F-fluorodeoxyglucose (18 FDG) positron emission tomography (PET)/CT imaging in a high-risk population for adrenal malignancy using an optimal reference standard. Retrospective cohort study. Imaging studies of patients with adrenal nodules who underwent adrenal biopsy and/or adrenalectomy between 1994 and 2014 were reviewed and compared to the reference standard of histology. Eighty % of patients presented with known or suspected extra-adrenal malignancy. Unenhanced abdominal CT was performed in 353 patients with adrenal lesions; median size was 3 (0.7-15) cm and median radiodensity was 33 (-21-78) Hounsfield units (HU). Radiodensity of >10 HU diagnosed malignancy with a sensitivity of 100%, specificity of 33%, positive predictive value (PPV) of 72% and negative predictive value (NPV) of 100%. 18 FDG-PET/CT was performed in 89 patients; median tumour size was 2.1 (0.7-9.2) cm. Maximum standardized uptake (SUV max) was higher in malignant lesions when compared to benign lesions (median=10 [2.3-29.4] vs 3.7 [1.4-24.5], respectively, P1.8 diagnosed malignancy with a sensitivity of 87%, specificity of 84%, PPV of 85% and NPV of 86%. Noncontract CT radiodensity of ≤10 HU excludes malignancy even in a high-risk population. For indeterminate adrenal lesions, given a superior specificity, 18 FDG-PET/CT could be considered as a second stage imaging study. © 2017 John Wiley & Sons Ltd.

  3. Limited Identification of Dual-time-point Positron Emission Tomography/Computed Tomography in Advanced Colorectal Neoplasms.

    Science.gov (United States)

    Kashiwagi, Kazuhiro; Nakazato, Yoshihiro; Arai, Mari; Iwasaki, Eisuke; Naganuma, Makoto; Inoue, Nagamu; Iwao, Yasushi; Ogata, Haruhiko; Murakami, Koji; Kanai, Takanori

    2017-01-01

    Objective We investigated whether dual-time-point 18-Fluorodeoxyglucose (18FDG) positron emission tomography/computed tomography (PET/CT) could improve the positive predictive value for detecting advanced colorectal neoplasms (cancer, adenoma ≥10 mm or adenoma with high-grade dysplasia). Methods We retrospectively searched for consecutive patients with a known primary cancer, who had a colonic 18FDG uptake incidentally found by PET/CT, followed by colonoscopy between January 2013 and August 2014. The clinical characteristics including the maximum standardized uptake value (SUVmax) were compared between advanced colorectal neoplasms and non-advanced lesions. Results Forty-eight patients had 51 foci with an incidental focal colorectal uptake of 18FDG. Among these 51 foci, 28 foci were judged as being advanced neoplasms, whereas 23 foci identified as non-advanced lesions. Four cases were missed by PET/CT: two laterally spreading tumors (LSTs) with intramucosal cancer and two severe adenomas (neoplasms was 55%. The per-spot performance of PET/CT showed that SUVmax was significantly higher in advanced neoplasms than in non-advanced lesions for the early-phase (10.1±4.9 vs. 6.5±3.2, p=0.029) and the delayed-phase (12.0±6.0 vs. 7.4±4.0, p=0.022). However, more importantly, there was a significant overlap of the SUVmax and no significant difference was found in the retention index (19.2±20.1 vs. 16.6±29.4, p=0.767). Conclusion Dual-time-point PET/CT was found to have limited impact for identifying advanced colorectal neoplasms in spite of its high sensitivity and it might therefore not be able to identify either LSTs or small advanced neoplasms.

  4. Advantages and disadvantages of F-18 fluorodeoxyglucose positron emission tomography/computed tomography in carcinoma of unknown primary.

    Science.gov (United States)

    Yu, Xiaozhou; Li, Xiaofeng; Song, Xiuyu; Dai, Dong; Zhu, Lei; Zhu, Yanjia; Wang, Jian; Zhao, Huiqin; Xu, Wengui

    2016-11-01

    Carcinoma of unknown primary is a type of malignant disease where the primary carcinoma cannot be identified by conventional examination, which presents challenges in diagnosis and therapy. This study aims to evaluate the detailed clinical value and indications of using fluorine-18-2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (F-18 FDG PET/CT) in a large sample. A total of 449 patients who were selected under strict standards were retrospectively included in this study. F-18 FDG PET/CT accurately detected the primary carcinoma in 115 of 449 patients whose primaries could not be detected by conventional examination (25.6%), with additional 27 false-positive patients. The most common primary site was the lung (34.8%). In addition, except for in metastatic melanoma (1/19, 5.3%) and axillary metastasis patients (2/49, 4.1%), F-18 FDG PET/CT had a comparative performance in detecting primary carcinoma in other pathological types and anatomical locations. The scan is able to guide treatment strategy modifications to some extent (130/449, 29.0%). We strongly recommend the use of F-18 FDG PET/CT in the early phase of examination. It is also recommended as a supplementary radiological method, and certain patients may benefit from its application in cases where regular examination is inconclusive. However, in metastatic melanoma or axillary metastasis patients where the primary site cannot be identified by routine examination, regular application of F-18 FDG PET/CT for the sole purpose of detecting the primary carcinoma should not be encouraged.

  5. Prognostic Impact of Pretreatment Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography SUVmax in Patients With Locally Advanced Cervical Cancer.

    Science.gov (United States)

    Cima, Simona; Perrone, Anna Myriam; Castellucci, Paolo; Macchia, Gabriella; Buwenge, Milly; Cammelli, Silvia; Cilla, Savino; Ferioli, Martina; Ferrandina, Gabriella; Galuppi, Andrea; Salizzoni, Eugenio; Rubino, Daniela; Fanti, Stefano; De Iaco, Pierandrea; Morganti, Alessio Giuseppe

    2018-01-24

    The aim of this study was to investigate the impact of SUVmax fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) measured in the primary tumor, pelvic and para-aortic node with disease-free survival (DFS) and overall survival (OS) in patients with locally advanced cervical cancer. A total of 92 patients with histological diagnosis of locally advanced cervical cancer are treated with radiochemotherapy plus brachytherapy boost from January 2008 to April 2014 in our Institution. A pretreatment FDG-PET/CT for staging and radiotherapy planning was performed, and the value of SUVmax measured in primary tumor and positive nodes was related to DFS and OS. Univariate analysis showed that DFS is related to FDG-PET/CT positive para-aortic nodes (P = 0.01), International Federation of Gynecology and Obstetrics (FIGO) stage of disease (P = 0.01), and primary tumor SUVmax (P = 0.02), and OS is related to positive para-aortic nodes (P = 0.01) and primary tumor SUVmax (P = 0.02).In multivariate analysis, DFS is modified by FDG-PET/CT positive para-aortic lymph nodes, stage and high T SUVmax (P = 0.02; P = 0.003; P = 0.04), but the only worse prognostic factor of OS is the high SUVmax in the primary tumor (P = 0.01). We found that T SUVmax, stage, and para-aortic lymph node status assessed by FDG-PET were independent prognostic factors of DFS, whereas only T SUVmax correlated with OS.

  6. 18-Fluoro-2-deoxyglucose positron emission tomography-computed tomography: an additional tool in the diagnosis of prosthetic valve endocarditis.

    Science.gov (United States)

    Ricciardi, Alessandra; Sordillo, Pasquale; Ceccarelli, Laura; Maffongelli, Gaetano; Calisti, Giorgio; Di Pietro, Barbara; Caracciolo, Cristiana Ragano; Schillaci, Orazio; Pellegrino, Antonio; Chiariello, Luigi; Andreoni, Massimo; Sarmati, Loredana

    2014-11-01

    To evaluate the role of 18-fluoro-2-deoxyglucose positron emission tomography-computed tomography ((18)F-FDG-PET-CT) in the diagnosis of infectious endocarditis (IE). We retrospectively examined 27 consecutive patients who were admitted to the Infectious Diseases Department of Tor Vergata University Hospital between 2009 and 2013 with a suspicion of IE. The final IE diagnosis was defined according to the modified Duke criteria, and the microbiological and diagnostic results were collected for each patient. Twenty out of 27 patients had a suspected prosthetic valve endocarditis (PVE) and seven had a suspected native valve endocarditis (NVE). Twenty-five out of 27 patients (92%) had a confirmed diagnosis of IE (18/25 PVE and 7/25 NVE); 16 had a positive echocardiography evaluation and 16 had positive (18)F-FDG-PET-CT findings. Echocardiography showed a higher sensitivity as a diagnostic tool for the detection of IE compared to (18)F-FDG-PET-CT (80% vs. 55%). However, a greater number of PVE had positive (18)F-FDG-PET-CT results compared to those with positive echocardiography findings (11/13 vs. 9/13), and overall 89% (16/18) of confirmed PVE resulted (18)F-FDG-PET-CT positive. Analyzing only the cases who underwent transoesophageal echocardiography, (18)F-FDG-PET-CT showed a sensitivity of 85% in PVE (vs. 69% for echocardiography and 77% for the Duke criteria). All seven patients with NVE had a positive echocardiography and negative (18)F-FDG-PET-CT findings (p<0.001). The results of this study further highlight the limitations of echocardiography in the diagnosis of PVE and the potential advantages of (18)F-FDG-PET-CT in these cases.

  7. Whole-body positron emission tomography using fluorodeoxyglucose for staging of lymphoma: effectiveness and comparison with computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Stumpe, K.D.M.; Urbinelli, M.; Steinert, H.C.; Glanzmann, C.; Buck, A.; von Schulthess, G.K. [Department of Medical Radiology, University Hospital, Zurich (Switzerland)

    1998-07-01

    The purpose of this study was to evaluate whole-body positron emission tomography (WB-PET) as a staging modality in Hodgkin`s disease (HD) and non-Hodgkin lymphoma (NHL) and to compare it with computed tomography (CT) in a retrospective study. Seventy-one WB-PET studies using fluorodeoxyglucose (FDG) and 49 CT examinations were performed in 19 women and 31 men. Transaxial images were acquired and reformatted coronally and sagittally in PET. CT sections were obtained from the skull base to the pelvic floor. The written reports of the imaging data were compared with a reference standard constructed on the basis of all the data on the individual patients, including clinical follow-up of at least 6 months. The sensitivity and specificity of PET were, respectively, 86% and 96% for HD (n=53), and 89% and 100% for NHL (n=18). For CT sensitivity and specificity were 81% and 41% for HD (n=33) and 86% and 67% for NHL (n=16). Differences between PET and CT sensitivities were not significant, while in HD there was a significant difference in the specificity of PET and CT examinations, mainly because CT was unable to distinguish between active or recurrent disease and residual scar tissue after therapy. FDG tumour uptake was found in high- as well as low-grade NHL patients. In conclusion, PET appears to be highly sensitive and specific for staging of lymphoma. It is at least as sensitive as CT, and more specific, particularly in patients undergoing restaging, where a well-recognized diagnostic dilemma in CT is the presence of a post-therapeutic residual mass. (orig.) With 4 figs., 3 tabs., 23 refs.

  8. Computed tomography myocardial perfusion vs {sup 15}O-water positron emission tomography and fractional flow reserve

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Michelle C.; Dweck, Marc R.; Golay, Saroj K. [University of Edinburgh/British Heart Foundation Centre for Cardiovascular Science, Edinburgh (United Kingdom); Mirsadraee, Saeed; Weir, Nicholas W.; Fletcher, Alison; Lucatelli, Christophe; Reid, John H. [University of Edinburgh, Clinical Research Imaging Centre, Edinburgh (United Kingdom); MacGillivray, Tom; Van Beek, Edwin J.R.; Newby, David E. [University of Edinburgh/British Heart Foundation Centre for Cardiovascular Science, Edinburgh (United Kingdom); University of Edinburgh, Clinical Research Imaging Centre, Edinburgh (United Kingdom); Cruden, Nicholas L.; Henriksen, Peter A.; Uren, Neal [Edinburgh Heart Centre, Royal Infirmary of Edinburgh, Edinburgh (United Kingdom); McKillop, Graham; Patel, Dilip [Department of Radiology, Royal Infirmary of Edinburgh, Edinburgh (United Kingdom); Lima, Joao A.C. [Johns Hopkins Hospital, Departments of Medicine and Radiology, Baltimore, MD (United States)

    2017-03-15

    Computed tomography (CT) can perform comprehensive cardiac imaging. We compared CT coronary angiography (CTCA) and CT myocardial perfusion (CTP) with {sup 15}O-water positron emission tomography (PET) and invasive coronary angiography (ICA) with fractional flow reserve (FFR). 51 patients (63 (61-65) years, 80 % male) with known/suspected coronary artery disease (CAD) underwent 320-multidetector CTCA followed by ''snapshot'' adenosine stress CTP. Of these 22 underwent PET and 47 ICA/FFR. Obstructive CAD was defined as CTCA stenosis >50 % and CTP hypoperfusion, ICA stenosis >70 % or FFR <0.80. PET hyperaemic myocardial blood flow (MBF) was lower in obstructive than non-obstructive territories defined by ICA/FFR (1.76 (1.32-2.20) vs 3.11 (2.44-3.79) mL/(g/min), P < 0.001) and CTCA/CTP (1.76 (1.32-2.20) vs 3.12 (2.44-3.79) mL/(g/min), P < 0.001). Baseline and hyperaemic CT attenuation density was lower in obstructive than non-obstructive territories (73 (71-76) vs 86 (84-88) HU, P < 0.001 and 101 (96-106) vs 111 (107-114) HU, P 0.001). PET hyperaemic MBF corrected for rate pressure product correlated with CT attenuation density (r = 0.579, P < 0.001). There was excellent per-patient sensitivity (96 %), specificity (85 %), negative predictive value (90 %) and positive predictive value (94 %) for CTCA/CTP vs ICA/FFR. CT myocardial attenuation density correlates with {sup 15}O-water PET MBF. CTCA and CTP can accurately identify obstructive CAD. (orig.)

  9. (18) F-fluorodeoxyglucose positron emission tomography/computed tomography for the detection of recurrent bone and soft tissue sarcoma.

    Science.gov (United States)

    Al-Ibraheem, Akram; Buck, Andreas K; Benz, Matthias R; Rudert, Maximilian; Beer, Ambros J; Mansour, Asem; Pomykala, Kelsey L; Haller, Bernhard; Juenger, Hendrik; Scheidhauer, Klemens; Schwaiger, Markus; Herrmann, Ken

    2013-03-15

    The clinical utility of modern hybrid imaging modalities for detecting recurrent bone or soft tissue sarcoma remains to be determined. In this report, the authors present a clinical study on the diagnostic accuracy and incremental value of integrated (18) F-fluorodeoxyglucose positron emission tomography/computed tomography ((18) F-FDG PET/CT) in patients with a history of sarcoma who have clinically suspected disease recurrence. Forty-three patients who had a history of bone or soft tissue sarcoma and had documented complete remission underwent (18) F-FDG PET/CT. Image analysis was performed independently for (18) F-FDG PET (n = 43) and for contrast-enhanced spiral CT (CE-CT) (n = 30) by 2 separate readers, whereas combined (18) F-FDG PET/CT (n = 43) images were analyzed in consensus by both readers. Imaging findings were rated on a 5-point scale and finally were reported as malignant, benign, or equivocal. Imaging findings were validated either by histopathology (n = 24) or by clinical follow-up (n = 19). (18) F-FDG PET/CT had greater sensitivity and specificity compared with CE-CT alone (94% and 92% vs 78% and 67%, respectively), resulting in significantly greater accuracy (93% vs 73%; P = .03). (18) F-FDG PET/CT was particularly superior regarding detection of local recurrence or soft tissue lesions (sensitivity and specificity: 83% and 100% vs 50% and 100%, respectively) or bone metastases (100% and 100% vs 85% and 88%, respectively). (18) F-FDG PET/CT had greater diagnostic accuracy in the detection of recurrent bone or soft tissue sarcoma compared with CE-CT alone. The detection of local recurrence was the most evident advantage of (18) F-FDG PET/CT over CE-CT. Cancer 2013. © 2012 American Cancer Society. Copyright © 2012 American Cancer Society.

  10. Positron Emission Tomography/Magnetic Resonance Imaging for Local Tumor Staging in Patients With Primary Breast Cancer: A Comparison With Positron Emission Tomography/Computed Tomography and Magnetic Resonance Imaging.

    Science.gov (United States)

    Grueneisen, Johannes; Nagarajah, James; Buchbender, Christian; Hoffmann, Oliver; Schaarschmidt, Benedikt Michael; Poeppel, Thorsten; Forsting, Michael; Quick, Harald H; Umutlu, Lale; Kinner, Sonja

    2015-08-01

    This study aimed to assess the diagnostic performance of integrated positron emission tomography (PET)/magnetic resonance imaging (MRI) of the breast for lesion detection and local tumor staging of patients with primary breast cancer in comparison to PET/computed tomography (CT) and MRI. The study was approved by the local institutional review board. Forty-nine patients with biopsy-proven invasive breast cancer were prospectively enrolled in our study. All patients underwent a PET/CT, and subsequently, a contrast-enhanced PET/MRI of the breast after written informed consent was obtained before each examination. Two radiologists independently evaluated the corresponding data sets (PET/CT, PET/MRI, and MRI) and were instructed to identify primary tumors lesions as well as multifocal/multicentric and bilateral disease. Furthermore, the occurrence of lymph node metastases was assessed, and the T-stage for each patient was determined. Histopathological verification of the local tumor extent and the axillary lymph node status was available for 30 of 49 and 48 of 49 patients, respectively. For the remaining patients, a consensus characterization was performed for the determination of the T-stage and nodal status, taking into account the results of clinical staging, PET/CT, and PET/MRI examinations. Statistical analysis was performed to test for differences in diagnostic performance between the different imaging procedures. P values less than 0.05 were considered to be statistically significant. Positron emission tomography/MRI and MRI correctly identified 47 (96%) of the 49 patients with primary breast cancer, whereas PET/CT enabled detection of 46 (94%) of 49 breast cancer patients and missed a synchronous carcinoma in the contralateral breast in 1 patient. In a lesion-by-lesion analysis, no significant differences could be obtained between the 3 imaging procedures for the identification of primary breast cancer lesions (P > 0.05). Positron emission tomography/MRI and

  11. Molecular pathology in vulnerable carotid plaques: correlation with [18]-fluorodeoxyglucose positron emission tomography (FDG-PET)

    DEFF Research Database (Denmark)

    Graebe, M; Pedersen, Sune Folke; Borgwardt, L

    2008-01-01

    before carotid endarterectomy. Plaque mRNA expression of the inflammatory cytokine interleukin 18 (IL-18), the macrophage-specific marker CD68 and the two proteinases, Cathepsin K and matrix metalloproteinase 9 (MMP-9), were quantified using real-time quantitative polymerase chain reaction. RESULTS......OBJECTIVES: Atherosclerosis is recognised as an inflammatory disease, and new diagnostic tools are warranted to evaluate plaque inflammatory activity and risk of cardiovascular events. We investigated [18]-fluorodeoxyglucose (FDG) uptake in vulnerable carotid plaques visualised by positron emission...... tomography (PET). Uptake was correlated to quantitative gene expression of known markers of inflammation and plaque vulnerability. METHODS: Ten patients with recent transient ischaemic attack and carotid artery stenosis (>50%) underwent combined FDG-PET and computed tomography angiography (CTA) the day...

  12. Risk of malignancy in thyroid incidentalomas detected by (18)f-fluorodeoxyglucose positron emission tomography

    DEFF Research Database (Denmark)

    Soelberg, Kerstin; Bonnema, Steen Joop; Brix, Thomas Heiberg

    2012-01-01

    Background: The expanding use of (18)F-fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) has led to the identification of increasing numbers of patients with an incidentaloma in the thyroid gland. We aimed to review the proportion of incidental thyroid cancers found by (18)F-FDG PET...... or PET/computed tomography imaging. Methods: Studies evaluating thyroid carcinomas discovered incidentally in patients or healthy volunteers by (18)F-FDG PET were systematically searched in the PubMed database from 2000 to 2011. The main exclusion criteria were known thyroid disease, lack of assigned...... diagnoses, investigation of diffuse uptake only, or investigation of patients with head and neck cancer, or cancer in the upper part of the thorax. Results: Twenty-two studies met our criteria comprising a total of 125,754 subjects. Of these, 1994 (1.6%) had unexpected focal hypermetabolic activity, while...

  13. Extensive Tattoos Mimicking Lymphatic Metastasis on Positron Emission Tomography Scan in a Patient With Cervical Cancer.

    Science.gov (United States)

    Grove, Narine; Zheng, Ma; Bristow, Robert E; Eskander, Ramez N

    2015-07-01

    Positron emission tomography (PET) fused with computed tomography (CT) imaging is common in the clinical assessment of patients with locally advanced cervical cancer. Limitations to the utilization and interpretation of PET-CT scans in patients with cervical cancer have been described, including false-positive findings secondary to tattoo ink. A 32-year-old woman presented with clinical stage 1B1 cervical cancer and extensive tattoos of the lower extremities. Preoperative PET-CT scan identified two ileac lymph nodes with increased fluorine-18-deoxyglucose uptake suspicious for metastatic disease. At the time of surgical resection, bilateral pigmented lymph nodes were identified with histologic examination showing deposition of tattoo ink and no malignant cells. Physicians should be cognizant of the possible effects of tattoos on PET-CT findings while counseling patients and formulating a treatment program.

  14. DETECTION OF MYOCARDIAL VIABILITY IN ISСHAEMIC DAMAGE USING MAGNETIC RESONANCE AND EMISSION TOMOGRAPHY

    Directory of Open Access Journals (Sweden)

    V. Yu. Ussov

    2013-01-01

    Full Text Available A review of modern methods of magnetic resonance imaging (MRI and emission tomography (singlephoton emission and positron emission computer tomography – SPECT and PET as toos for diagnosis and prognosis of myocardial ischaemic damage, in particular in coronary revascularization. The definition of term “myocardial viability” is discussed. It has been shown that the integrity of blood-tissue barrier between myocardium and microcirculatory vessels is the most sensitive marker of tissue viability and of functional integrity of myocardium. It’s evaluation by means of contrast-enhanced MRI of myocardium is the most available and most precise technique of diagnosis and prognosis both in patients with postinfarction myocardiosclerosis and in patients with coronary disease without myocardial infarction. It is proposed that in the nearest future the combination of MR-coronarography and contrast-enhanced MRI of myocardium will provide a possibility to obtain the full set of data necessary for planning of endovascular and surgical treatment of various forms of coronary heart disease. PET and SPECT techniques currently are of some essential interest for pathophysiologic research of coronary ishaemia in clinical and experimental studies as well as for qualitative visual studies of pharmacokinetics.

  15. Comparison of Diagnostic Performance of Three-Dimensional Positron Emission Mammography versus Whole Body Positron Emission Tomography in Breast Cancer

    Directory of Open Access Journals (Sweden)

    Dong Dai

    2017-01-01

    Full Text Available Objective. To compare the diagnostic performance of three-dimensional (3D positron emission mammography (PEM versus whole body positron emission tomography (WBPET for breast cancer. Methods. A total of 410 women with normal breast or benign or highly suspicious malignant tumors were randomized at 1 : 1 ratio to undergo 3D-PEM followed by WBPET or WBPET followed by 3D-PEM. Lumpectomy or mastectomy was performed on eligible participants after the scanning. Results. The sensitivity and specificity of 3D-PEM were 92.8% and 54.5%, respectively. WBPET showed a sensitivity of 95.7% and specificity of 56.8%. After exclusion of the patients with lesions beyond the detecting range of the 3D-PEM instrument, 3D-PEM showed higher sensitivity than WBPET (97.0% versus 95.5%, P = 0.913, particularly for small lesions (<1 cm (72.0% versus 60.0%, P = 0.685. Conclusions. The 3D-PEM appears more sensitive to small lesions than WBPET but may fail to detect lesions that are beyond the detecting range. This study was approved by the Ethics Committee (E2012052 at the Tianjin Medical University Cancer Institute and Hospital (Tianjin, China. The instrument positron emission mammography (PEMi was approved by China State Food and Drug Administration under the registration number 20153331166.

  16. Positron emission tomography in the diagnosis and staging of lung cancer

    DEFF Research Database (Denmark)

    Fischer, B M; Mortensen, J; Højgaard, L

    2001-01-01

    Lung cancer is the cause of 32% of all male cancer deaths and 25% of all female cancer deaths. Because the prognosis depends on early diagnosis and staging, continuous evaluation of the diagnostic tools available is important. The aim of this study was to assess the diagnostic value of dedicated...... positron emission tomography (PET) and gamma-camera PET in the diagnostic investigation of non-small-cell lung cancer (NSCLC). A systematic literature search was carried out in the MEDLINE and EMBASE databases and the Cochrane Controlled Trials Register. We identified 55 original works on the diagnostic...

  17. Regional cerebral glucose metabolism during sevoflurane anaesthesia in healthy subjects studied with positron emission tomography

    DEFF Research Database (Denmark)

    Schlünzen, L; Juul, N; Hansen, K V

    2010-01-01

    BACKGROUND: The precise mechanism by which sevoflurane exerts its effects in the human brain remains unknown. In the present study, we quantified the effects of sevoflurane on regional cerebral glucose metabolism (rGMR) in the human brain measured with positron emission tomography. METHODS: Eight...... monitored and bispectral index responses were registered. Statistical parametric maps and conventional regions of interest analysis were used to determine rGMR differences. RESULTS: All subjects were unconsciousness at 1.0 MAC sevoflurane. Cardiovascular and respiratory parameters were constant over time...

  18. Reliability of eye lens dosimetry in workers of a positron emission tomography radiopharmaceutical production facility.

    Science.gov (United States)

    da Silva, Teógenes A; Guimarães, Margarete C; Meireles, Leonardo S; Teles, Luciana L D; Lacerda, Marco Aurélio S

    2016-11-01

    A new regulatory statement was issued concerning the eye lens radiation protection of persons in planned exposures. A debate was raised on the adequacy of the dosimetric quantity and on its method of measurement. The aim of this work was to establish the individual monitoring procedure with the EYE-D™ holder and a MCP-N LiF:Mg,Cu,P thermoluminescent chip detector for measuring the personal dose equivalent Hp(3) in workers of a Positron Emission Tomography Radiopharmaceutical Production Facility. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. (18) F-Labeling of Sensitive Biomolecules for Positron Emission Tomography.

    Science.gov (United States)

    Krishnan, Hema S; Ma, Longle; Vasdev, Neil; Liang, Steven H

    2017-11-07

    Positron emission tomography (PET) imaging study of fluorine-18 labeled biomolecules is an emerging and rapidly growing area for preclinical and clinical research. The present review focuses on recent advances in radiochemical methods for incorporating fluorine-18 into biomolecules via "direct" or "indirect" bioconjugation. Recently developed prosthetic groups and pre-targeting strategies, as well as representative examples in (18) F-labeling of biomolecules in PET imaging research studies are highlighted. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Radiolabeled phosphonium salts as mitocondrial voltage sensors for positron emission tomography myocardial imaging agents

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Yon; Min, Jung Joon [Dept. of Nuclear Medicine,Chonnam National University Medical School and Hwasun Hospital, Gwangju (Korea, Republic of)

    2016-09-15

    Despite substantial advances in the diagnosis of cardiovascular disease, {sup 18}F-labeled positron emission tomography (PET) radiopharmaceuticals remain necessary to diagnose heart disease because clinical use of current PET tracers is limited by their short half-life. Lipophilic cations such as phosphonium salts penetrate the mitochondrial membranes and accumulate in mitochondria of cardiomyocytes in response to negative inner-transmembrane potentials. Radiolabeled tetraphenyl phosphonium cation derivatives have been developed as myocardial imaging agents for PET. In this review, a general overview of these radiotracers, including their radiosynthesis, in vivo characterization, and evaluation is provided and clinical perspectives are discussed.

  1. Imaging of Carbon Translocation to Fruit Using Carbon-11-Labeled Carbon Dioxide and Positron Emission Tomography

    Science.gov (United States)

    Kawachi, Naoki; Kikuchi, Kaori; Suzui, Nobuo; Ishii, Satomi; Fujimaki, Shu; Ishioka, Noriko S.; Watabe, Hiroshi

    2011-04-01

    Carbon kinetics into the fruit is an agricultural issue on the growth and development of the sink organs to be harvested. Particularly, photoassimilate translocation and distribution are important topics for understanding the mechanism. In the present work, carbon-11 (11C) labeled photoassimilate translocation into fruits of tomato has been imaged using carbon-11-labeled carbon dioxide and the positron emission tomography (PET). Dynamice PET data of gradual increasing of 11C activity and its distribution is acquired quantitatively in intact plant body. This indicates that the 3-D photoassimilate translocation into the fruits is imaged successfully and carbon kinetics is analyzable to understand the plant physiology and nutrition.

  2. In vivo biodistribution of amino-functionalized ceria nanoparticles in rats using positron emission tomography.

    Science.gov (United States)

    Rojas, Santiago; Gispert, Juan Domingo; Abad, Sergio; Buaki-Sogo, Mireia; Victor, Victor M; Garcia, Hermenegildo; Herance, Jose Raúl

    2012-12-03

    A variety of nanoparticles have been proposed for several biomedical applications. To gauge the therapeutic potential of these nanoparticles, in vivo biodistribution is essential and mandatory. In the present study, ceria nanoparticles (5 nm average particle size) were labeled with (18)F to study their in vivo biodistribution in rats by positron emission tomography (PET). The (18)F isotope was anchored by reaction of N-succinimidyl 4-[(18)F]fluorobenzoate ((18)F-SFB) with a modified nanoparticle surface obtained by silylation with 3-aminopropylsilyl. Radiolabeled ceria nanoparticles accumulated mainly in lungs, spleen, and liver. Metabolic products of the radiolabeled nanoparticulate material were excreted into the urinary tract.

  3. Advances in Single-Photon Emission Computed Tomography Hardware and Software.

    Science.gov (United States)

    Piccinelli, Marina; Garcia, Ernest V

    2016-02-01

    Nuclear imaging techniques remain today's most reliable modality for the assessment and quantification of myocardial perfusion. In recent years, the field has experienced tremendous progress both in terms of dedicated cameras for cardiac applications and software techniques for image reconstruction. The most recent advances in single-photon emission computed tomography hardware and software are reviewed, focusing on how these improvements have resulted in an even more powerful diagnostic tool with reduced injected radiation dose and acquisition time. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Capillaries within compartments: microvascular interpretation of dynamic positron emission tomography data

    DEFF Research Database (Denmark)

    Munk, O L; Keiding, S; Bass, L

    2003-01-01

    Measurement of exchange of substances between blood and tissue has been a long-lasting challenge to physiologists, and considerable theoretical and experimental accomplishments were achieved before the development of the positron emission tomography (PET). Today, when modeling data from modern PET...... single- and multi-capillary systems and include effects of non-exchanging vessels. They are suitable for analysing dynamic PET data from any capillary bed using either intravascular or diffusible tracers, in terms of physiological parameters which include regional blood flow. Udgivelsesdato: 2003-Nov-7...

  5. Radiolabeled Phosphonium Salts as Mitochondrial Voltage Sensors for Positron Emission Tomography Myocardial Imaging Agents.

    Science.gov (United States)

    Kim, Dong-Yeon; Min, Jung-Joon

    2016-09-01

    Despite substantial advances in the diagnosis of cardiovascular disease, (18)F-labeled positron emission tomography (PET) radiopharmaceuticals remain necessary to diagnose heart disease because clinical use of current PET tracers is limited by their short half-life. Lipophilic cations such as phosphonium salts penetrate the mitochondrial membranes and accumulate in mitochondria of cardiomyocytes in response to negative inner-transmembrane potentials. Radiolabeled tetraphenylphosphonium cation derivatives have been developed as myocardial imaging agents for PET. In this review, a general overview of these radiotracers, including their radiosynthesis, in vivo characterization, and evaluation is provided and clinical perspectives are discussed.

  6. Painful spondylolysis or spondylolisthesis studied by radiography and single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Collier, B.D.; Johnson, R.P.; Carrera, G.F.; Meyer, G.A.; Schwab, J.P.; Flatley, T.J.; Isitman, A.T.; Hellman, R.S.; Zielonka, J.S.; Knobel, J.

    1985-01-01

    Planar bone scintigraphy (PBS) and single-photon emission computed tomography (SPECT) were compared in 19 adults with radiographic evidence of spondylolysis and/or spondylolisthesis. SPECT was more sensitive than PBS when used to identify symptomatic patients and sites of painful defects in the pars interarticularis. In addition, SPECT allowed more accurate localization than PBS. In 6 patients, spondylolysis or spondylolisthesis was unrealted to low back pain, and SPECT images of the posterior neural arch were normal. The authors conclude that when spondylolysis or spondylolisthesis is the cause of low back pain, pars defects are frequently heralded by increased scintigraphic activity which is best detected and localized by SPECT.

  7. Clinical correlates of decreased anteroposterior metabolic gradients in positron emission tomography (PET) of schizophrenic patients

    Energy Technology Data Exchange (ETDEWEB)

    DeLisi, L.E.; Buchsbaum, M.S.; Holcomb, H.H.; Dowling-Zimmerman, S.; Pickar, D.; Boronow, J.; Morihisa, J.M.; van Kammen, D.P.; Carpenter, W.; Kessler, R.

    1985-01-01

    The finding in schizophrenic patients of a reversal of the normal frontal to posterior pattern of brain metabolic activity with positron emission tomography (PET) is of interest, but its relevance to psychopathology is unknown. Using PET, the authors studied 21 patients with chronic schizophrenia and 21 age- and sex-matched control subjects. Although eight of the 21 patients and only one of the control subjects showed a relatively lower anteroposterior metabolic gradient, no clinical correlates of this finding were noted. In addition, cerebral atrophy, as determined by CAT scan, was not associated with this aberrant metabolic pattern.

  8. Evaluation of a 99Tcm bound brain scanning agent for single photon emission computed tomography

    DEFF Research Database (Denmark)

    Andersen, A R; Hasselbalch, S G; Paulson, O B

    1986-01-01

    D,L HM-PAO-99Tcm (PAO) is a lipophilic tracer complex which is avidly taken up by the brain. We have compared the regional distribution of PAO with regional cerebral blood flow (CBF). CBF was measured by single photon emission computed tomography (SPECT) by Tomomatic 64 after 133Xe inhalation in 41...... patients. With the same SPECT the distribution of PAO was measured after intravenous injection. High resolution (HR) and low resolution (LR) studies were performed yielding a resolution of 6-10 mm (HR) and 15-20 mm (LR). PAO images showed close resemblance to 133Xe CBF tomograms. Only 20 per cent...

  9. New Cyclotron Targetry to Enhance F-18 clinical Position Emission Tomography

    Energy Technology Data Exchange (ETDEWEB)

    J. Michael Doster

    2008-12-19

    This project proposes to develop cyclotron targets that produce F-18 for clinical Positron Emission Tomography (PET) at significantly higher rates than that available from current targetry. This production rate of 18F is directly proportional to the beam current. Higher beam currents would result in increased 18F production but would be accompanied by higher heat loads to the target. The beam power available in most commercial cyclotrons exceeds the heat removal capacity of current target technology by a factor of two to four, significantly limiting the production rate of Fluorine-18.

  10. Single photon image from position emission tomography with insertable collimator for boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Joo Young; Yoo, Do Kun; Suh, Tae Suk [Dept. of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, Catholic University of Korea, Seoul (Korea, Republic of); Hong, Key Jo [Molecular Imaging Program at Stanford (MIPS), Dept. of Radiology, Stanford University, Stanford (United States)

    2014-04-15

    The aim of our proposed system is to confirm the feasibility of extraction of two types of images from one positron emission tomography (PET) module with an insertable collimator for brain tumor treatment during the boron neutron capture therapy (BNCT). The BNCT theory and conceptual diagram of our proposed system are shown fig.1. Data from the PET module, neutron source, and collimator was entered in the Monte Carlon-particle extende source code. We attempted to acquire the PET and SPECT images simultaneously using only PET without an additional isotope. Single photon images were acquired using an insertable collimator on a PET detector.

  11. Simultaneous (68)Ga DOTATATE Positron Emission Tomography/Magnetic Resonance Imaging in Meningioma Target Contouring: Feasibility and Impact Upon Interobserver Variability Versus Positron Emission Tomography/Computed Tomography and Computed Tomography/Magnetic Resonance Imaging.

    Science.gov (United States)

    Maclean, J; Fersht, N; Sullivan, K; Kayani, I; Bomanji, J; Dickson, J; O'Meara, C; Short, S

    2017-07-01

    The increasing use of highly conformal radiation techniques to treat meningioma confers a greater need for accurate targeting. Several groups have shown that positron emission tomography/computed tomography (PET/CT) information alters meningioma targets contoured by single observers, but whether this translates into improved accuracy has not been defined. As magnetic resonance imaging (MRI) is the cornerstone of meningioma target contouring, simultaneous PET/MRI may be superior to PET/CT. We assessed whether (68)Ga DOTATATE PET imaging (from PET/CT and PET/MRI) reduced interobserver variability (IOV) in meningioma target volume contouring. Ten patients with meningioma underwent simultaneous (68)Ga DOTATATE PET/MRI followed by PET/CT. They were selected as it was anticipated that target volume definition in their cases would be particularly challenging. Three radiation oncologists contoured target volumes according to an agreed protocol: gross tumour volume (GTV) and clinical target volume (CTV) on CT/MRI alone, CT/MRI+PET(CT) and CT/MRI+PET(MRI). GTV/CTV Kouwenhoven conformity levels (KCL), regions of contour variation and qualitative differences between PET(CT) and PET(MRI) were evaluated. There was substantial IOV in contouring. GTV mean KCL: CT/MRI 0.34, CT/MRI+PET(CT) 0.38, CT/MRI+PET(MRI) 0.39 (P = 0.06). CTV mean KCL: CT/MRI 0.31, CT/MRI+PET(CT) 0.35, CT/MRI+PET(MRI) 0.35 (P = 0.04 for all groups; P > 0.05 for individual pairs). One observer consistently contoured largest and one smallest. Observers rarely decreased volumes in relation to PET. Most IOV occurred in bone followed by dural tail, postoperative bed and venous sinuses. Tumour edges were qualitatively clearer on PET(MRI) versus PET(CT), but this did not affect contouring. IOV in contouring challenging meningioma cases was large and only slightly improved with the addition of (68)Ga DOTATATE PET. Simultaneous PET/MRI for meningioma contouring is feasible, but did not improve IOV versus PET

  12. Virtual Reality Therapy for the Treatment of Alcohol Dependence: A Preliminary Investigation With Positron Emission Tomography/Computerized Tomography.

    Science.gov (United States)

    Son, Ji Hyun; Lee, Sang Hoon; Seok, Ju Won; Kee, Baik Seok; Lee, Hyun Woong; Kim, Hyung Joon; Lee, Tae Kyung; Han, Doug Hyun

    2015-07-01

    Virtual reality therapy (VRT) uses multimodal stimulation that includes visual, auditory, olfactory, and gustatory stimuli. The aim of this study was to assess the effectiveness of VRT in treating subjects with alcohol dependence (AD) by evaluating changes in brain metabolism. The VRT protocol consisted of three steps: relaxation, presentation of a high-risk situation, and presentation of an aversive situation. Twelve alcohol-dependent subjects underwent 10 sessions of VRT. The alcohol-dependent subjects were assessed with 18F-fluorodeoxyglucose positron emission tomography images before and after VRT, whereas the control group underwent imaging according to the same protocol only at baseline. Compared with the healthy control group, AD subjects showed higher metabolism in the right lentiform nucleus and right temporal lobe (BA20) at baseline (P(FDR brain metabolism in the right lentiform nucleus (P(FDR < .05) = .026) and right temporal lobe (BA38, P(FDR < .05) = .032) relative to that at baseline. Our results suggest a neurobiological imbalance, notably, a high sensitivity to stimuli, in the limbic system in subjects with AD. Furthermore, we determined that metabolism decreased in the basal ganglia after VRT, which may explain the limbic-regulated responses of reward and regulation. Therefore, we tentatively recommend VRT to treat AD through its regulating effect on limbic circuits.

  13. Synthesis and evaluation of fluorinated derivatives of fentanyl as candidates for opiate receptor studies using positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Dahren Hwang; Feliu, A.L.; Wolf, A.P.; MacGregor, R.R.; Fowler, J.S.; Arnett, C.D.

    1986-03-01

    Three fluorinated derivatives of fentanyl, fluorofentanyl (3), keto-fluorofentanyl (5), and fluorofentanol (6), were synthesized and their abilities to compete with /sup 3/diprenorphine for binding sites in guinea pig brain membranes were determined. The relative potencies were fentanyl > 3 approx.= 6 >> 5. On the basis of its apparent affinity for opiate receptors and its relative ease of synthesis, 6 was selected for further study. Fentanyl was slightly better than 6 in its ability to compete with (/sup 3/H)naltrexone for binding sites in rat brain membranes. Both fentayl and 6 exhibited a similar high ''sodium ratio'' (quotient of the IC/sub 50/'s against (/sup 3/H)naltrexone in the presence and absence of sodium chloride) generally characteristic of opiate agonists. The analgesic potencies of fentanyl and 6 were determined in rats by measuring suppression of locomotion and vocalization responses to footshock. 6 appeared slightly less potent than fentanyl, but produced a similar analgesia and catalepsy which was entirely blocked by pretreatment of rats with naloxone, an opiate antagonist. A rapid synthesis of (/sup 18/F)-6 was developed and the tissue distribution of (/sup 18/F)-6 in mice was determined 5, 60, and 120 minutes after intravenous injection. The use of this general route to /sup 18/F-labeled derivatives of fentanyl for studies of the opiate receptor using positron emission tomography is planned.

  14. Technetium-99m methylene diphosphonate uptake in the brachialis muscle hematoma in a patient with prostate cancer and coagulation disorder mimicking bone metastasis evaluated by single-photon emission tomography-computed tomography/computed tomography.

    Science.gov (United States)

    Kamaleshwaran, Koramadai Karuppusamy; Mohanan, Vyshakh; Madhavan, Devdas; Shinto, Ajit Sugunan

    2013-10-01

    We report a case of 79-year-old male with prostate cancer and coagulation disorder presented with left shoulder pain. He underwent bone scintigraphy to rule out metastasis, which showed intense foci of tracer activity in the left axilla. Hybrid single-photon emission tomography-computed tomography (SPECT/CT) of the shoulder region localized tracer uptake to the left brachialis muscle hematoma.

  15. Prevalence of detecting unknown cerebral metastases in fluorodeoxyglucose positron emission tomography/computed tomography and its potential clinical impact.

    Science.gov (United States)

    Kung, Boom Ting; Auyong, T K; Tong, C M

    2014-05-01

    To determine the prevalence of incidental finding of unknown cerebral metastases and explore the clinical impact of detecting unknown brain metastases among individuals underwent whole body fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) with brain included in field of view. A retrospective review of 1876 patients who underwent whole body PET/CT examination in our clinical PET center for oncological evaluation from January 2009 to September 2009 was performed. The total number and prevalence of unknown brain metastases detected by PET/CT were calculated. Patients diagnosed with cerebral metastases by PET/CT were further analyzed via the electronic patient record system for relevant clinical and radiological findings. Positive predictive value of PET/CT for the diagnosis of cerebral metastases was calculated with reference to contrast enhanced magnetic resonance imaging (MRI) or contrast enhanced CT. Of the 1876 subjects, 71 patients (3.8%) were diagnosed with cerebral metastases by PET/CT. 31 patients were already diagnosed with brain metastases before PET/CT. Among the 40 patients with unknown brain metastasis, 24 (60.0%) underwent either MRI (n = 5) or CT (n = 19) after PET/CT, of which 17 patients were confirmed with cerebral metastases. The true positive rate was 70.8% (17/24), while the false positive rate of PET/CT was 29.2% (7/24). Nearly 94.1% (16/17) patients with confirmed cerebral metastases on MRI or CT had subsequent change in management. Among the remaining 16 patients with positive findings of cerebral metastases without further radiological correlation, 43.8% (7/16) patients had change in management after PET/CT. A total of 57.5% (23/40) patients had change in management after PET/CT. The point prevalence of detecting unknown cerebral metastases by PET/CT was 2.1% (40/1876). 94.1% patients with newly diagnosed brain metastases confirmed with either MRI or CT received immediate treatment for cerebral

  16. Massively parallel computers for 3D single-photon-emission computed tomography.

    Science.gov (United States)

    Butler, C S; Miller, M I; Miller, T R; Wallis, J W

    1994-03-01

    Since the introduction of the expectation-maximization (EM) algorithm for generating maximum-likelihood (ML) and maximum a posteriori (MAP) estimates in emission tomography, there have been many investigators applying the ML method. However, almost all of the previous work has been restricted to two-dimensional (2D) reconstructions. The major focus and contribution of this paper is to demonstrate a fully three-dimensional (3D) implementation of the MAP method for single-photon-emission computed tomography (SPECT). The 3D reconstruction exhibits an improvement in resolution when compared to the generation of the series of separate 2D slice reconstructions. As has been noted, the iterative EM algorithm for 2D reconstruction is highly computational; the 3D algorithm is far worse. To accommodate the computational complexity, we have extended our previous work in the 2D arena and demonstrate an implementation on the class of massively parallel processors of the 3D algorithm. Using a 16000 processor MasPar machine, the algorithm is demonstrated to execute at 1.24 s/EM iteration for the entire 64 x 64 x 64 cube of 64 planar measurements obtained from the Siemens Orbiter rotating camera operating in the high-resolution mode.

  17. Positron emission tomography for measurement of copper fluxes in live organisms

    Science.gov (United States)

    Peng, Fangyu

    2014-01-01

    Copper is an essential nutrient for the physiology of live organisms, but excessive copper can be harmful. Copper radioisotopes are used for measurement of copper fluxes in live organisms using a radioactivity assay of body fluids or whole-body positron emission tomography (PET). Hybrid positron emission tomography–computed tomography (PET/CT) is a versatile tool for real-time measurement of copper fluxes combining the high sensitivity and quantification capability of PET and the superior spatial resolution of CT for anatomic localization of radioactive tracer activity. Kinetic analysis of copper metabolism in the liver and other extra-hepatic tissues of Atp7b−/− knockout mice, a mouse model of Wilson’s disease, demonstrated the feasibility of measuring copper fluxes in live organisms with PET/CT using copper-64 chloride (64CuCl2) as a radioactive tracer (64CuCl2-PET/CT). 64CuCl2-PET/CT holds potential as a useful tool for diagnosis of inherited and acquired human copper metabolism disorders, and for monitoring the effects of copper-modulating therapy. PMID:24628290

  18. Imaging of McCune-Albright syndrome using bone single photon emission computed tomography.

    Science.gov (United States)

    Kairemo, K J; Verho, S; Dunkel, L

    1999-02-01

    McCune-Albright syndrome is a rare disorder caused by a somatic, constitutively activating mutation in the gene (GNAS1) encoding the subunit of the signal transducing guanine nucleotide binding protein (G protein). The condition is characterized by polyostotic fibrous dysplasia, cafe-au-lait pigmentation and multiple endocrine hyperfunction, most commonly gonadotropin-independent precocious puberty in girls. Our patient, a 16-year-old male, with radiologically confirmed polyostotic fibrous dysplasia in cranium, thoracic and pelvic girdles, spine and extremities was studied using planar 99mTc-hydroxymethyldiphosphonate bone scintigraphy and single photon emission computed tomography. Using bone scintigraphy, an unusually extensive and asymmetric fibrous dysplasia was observed in the cranium, face, ribs, femur, humerus, ulna, tibia and the vertebral column, all on the left side. The whole body scan revealed only a few foci on the right side. Single photon emission computed tomography demonstrated extensive unilateral involvement in the base of the skull, facial bones, maxilla and mandible. All the lesions reached only the midline. These findings formed the basis of further treatment, eg. reconstructive surgery of facial asymmetry. McCune-Albright syndrome should be considered in the differential diagnosis when interpreting extensive unilateral predominance in paediatric bone scans.

  19. Application of Positron Emission Tomography to Aerosol Transport Research in a Model of Human Lungs

    Directory of Open Access Journals (Sweden)

    Jicha M.

    2013-04-01

    Full Text Available Positron Emission Tomography (PET is a convenient method for measurement of aerosol deposition in complex models of lungs. It allows not only the evaluation of regional deposition characteristics but also precisely detects deposition hot spots. The method is based on a detection of a pair of annihilation photons moving in opposite directions as a result of positron – electron interaction after the positron emission decay of a suitable radioisotope. Liquid di(2-ethylhexyl sebacate (DEHS particles tagged with fluorine-18 as a radioactive tracer were generated by condensation monodisperse aerosol generator. Aerosol deposition was measured for three different inhalation flowrates and for two sizes of particles. Combination of PET with Computed Tomography (CT in one device allowed precise localisation of particular segments of the model. The results proved correlation of deposition efficiency with Stokes number, which means that the main deposition mechanism is inertial impaction. As a next task the methodology for tagging the solid aerosol particles with radioactive tracer will be developed and deposition of porous and fiber aerosols will be measured.

  20. Geneva University - The AX-PET experiment : A demonstrator for an axial Positron Emission Tomography

    CERN Multimedia

    Université de Genève

    2012-01-01

    Geneva University École de physique Département de physique nucléaire et corspusculaire 24, quai Ernest-Ansermet 1211 Genève 4 Tél.: (022) 379 62 73 Fax: (022) 379 69 92   Wednesday 14 March 2012 SEMINAIRE DE PHYSIQUE CORPUSCULAIRE 11.15 a.m. - Science II, Auditoire 1S081, 30, quai Ernest-Ansermet, 1211 Genève 4 The AX-PET experiment : A demonstrator for an axial Positron Emission Tomography Dr Chiara CASELLA   ETH Zurich   PET (Positron Emission Tomography) is a tool for in-vivo functional imaging, successfully used since the earliest days of nuclear medicine. It is based on the detection of the two coincident 511 keV photons from the annihilation of a positron, emitted from a radiotracer injected into the body. Tomographic analysis of the coincidence data allows for a 3D reconstructed image of the source distribution. The AX-PET experiment proposes a novel geometrical approach for a PET scanner, in which l...

  1. Positron emission tomography myocardial perfusion imaging in children with suspected coronary abnormalities.

    Science.gov (United States)

    Singh, T P; Muzik, O; Forbes, T F; Di Carli, M F

    2003-01-01

    Positron emission tomography (PET) myocardial perfusion imaging has higher spatial resolution than conventional single photon emission computed tomography (SPECT) imaging and allows accurate and reproducible quantification of myocardial blood flow (MBF). In this article, we describe the role of PET myocardial perfusion imaging in clinical decision making in children with suspected coronary abnormalities. We performed a PET myocardial perfusion study using N-13 ammonia in 10 children (median age, 14 years; range, 1-17 years). The indications included exercise-induced chest pain and ST segment changes during exercise testing, coronary artery ectasia, hypertrophic cardiomyopathy with myocardial bridging of the left anterior descending coronary artery, and suspected left coronary stenosis in an infant with William's syndrome. MBF was assessed at baseline and during adenosine hyperemia in all 10 patients and postexercise in 8 patients. Myocardial perfusion was homogeneous at baseline in all 10 patients, during adenosine perfusion in 9 of 10 patients, and postexercise in all 8 patients. Three patients with homogeneous rest and stress perfusion had impaired myocardial flow reserve. The infant with William's syndrome developed a large, reversible perfusion defect in the left coronary territory during adenosine stress and underwent surgical repair. Myocardial flow reserve findings were valuable for clinical decision making in individual patients. We conclude that MBF quantification with N-13 ammonia and PET provides supplemental perfusion information and is helpful in clinical decision making in children with suspected coronary abnormalities.

  2. Positron emission tomography in amyotrophic lateral sclerosis: Towards targeting of molecular pathological hallmarks

    Energy Technology Data Exchange (ETDEWEB)

    Willekens, Stefanie M.A.; Weehaeghe, Donatienne van [University Hospitals Leuven and KU Leuven, Division of Nuclear Medicine, Department of Imaging and Pathology, Leuven (Belgium); Damme, Philip van [University Hospitals Leuven, Department of Neurology, Leuven (Belgium); KU Leuven, Department of Neurosciences, Experimental Neurology, Leuven (Belgium); Leuven Research Institute for Neuroscience and Disease (LIND), Leuven (Belgium); VIB, Vesalius Research Center, Laboratory of Neurobiology, Leuven (Belgium); Laere, Koen van [University Hospitals Leuven and KU Leuven, Division of Nuclear Medicine, Department of Imaging and Pathology, Leuven (Belgium); Leuven Research Institute for Neuroscience and Disease (LIND), Leuven (Belgium)

    2017-03-15

    During the past decades, extensive efforts have been made to expand the knowledge of amyotrophic lateral sclerosis (ALS). However, clinical translation of this research, in terms of earlier diagnosis and improved therapy, remains challenging. Since more than 30% of motor neurons are lost when symptoms become clinically apparent, techniques allowing non-invasive, in vivo detection of motor neuron degeneration are needed in the early, pre-symptomatic disease stage. Furthermore, it has become apparent that non-motor signs play an important role in the disease and there is an overlap with cognitive disorders, such as frontotemporal dementia (FTD). Radionuclide imaging, such as positron emission tomography (PET) and single-photon emission computed tomography (SPECT), form an attractive approach to quantitatively monitor the ongoing neurodegenerative processes. Although [{sup 18}F]-FDG has been recently proposed as a potential biomarker for ALS, active targeting of the underlying pathologic molecular processes is likely to unravel further valuable disease information and may help to decipher the pathogenesis of ALS. In this review, we provide an overview of radiotracers that have already been applied in ALS and discuss possible novel targets for in vivo imaging of various pathogenic processes underlying ALS onset and progression. (orig.)

  3. DE-BLURRING SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY IMAGES USING WAVELET DECOMPOSITION

    Directory of Open Access Journals (Sweden)

    Neethu M. Sasi

    2016-02-01

    Full Text Available Single photon emission computed tomography imaging is a popular nuclear medicine imaging technique which generates images by detecting radiations emitted by radioactive isotopes injected in the human body. Scattering of these emitted radiations introduces blur in this type of images. This paper proposes an image processing technique to enhance cardiac single photon emission computed tomography images by reducing the blur in the image. The algorithm works in two main stages. In the first stage a maximum likelihood estimate of the point spread function and the true image is obtained. In the second stage Lucy Richardson algorithm is applied on the selected wavelet coefficients of the true image estimate. The significant contribution of this paper is that processing of images is done in the wavelet domain. Pre-filtering is also done as a sub stage to avoid unwanted ringing effects. Real cardiac images are used for the quantitative and qualitative evaluations of the algorithm. Blur metric, peak signal to noise ratio and Tenengrad criterion are used as quantitative measures. Comparison against other existing de-blurring algorithms is also done. The simulation results indicate that the proposed method effectively reduces blur present in the image.

  4. Three dimensional quantification of left ventricular wall motion by ECG-gated blood pool emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Underwood, S.R.; Walton, S.; Laming, P.J.; Jarritt, P.H.; Ell, P.J.; Emanuel, R.W.; Swanton, R.H.

    1985-05-01

    ECG-gated blood pool emission tomography is a relatively new technique, and this study establishes a simple method for displaying the three dimensional data obtained, determines a normal range for ejection fraction in all regions of the left ventricle, and compares wall motion in abnormal subjects with that determined by X-ray contrast ventriculography. The short axis sections dividing the ventricle in slices from apex to base, were used to calculate ejection fraction for all parts of the ventricle and the results were plotted on a single colour coded circular image. The apex was represented in the centre, the base around the circumference, and all other parts of the ventricle were represented in between. The image was divided into 15 segments, and normal segmental ejection fraction was defined as within two standard deviations of the mean in a group of 10 normal subjects. In 25 subjects with coronary artery disease, motion of the anterior, apical, and inferior walls agreed in every case with the right anterior oblique contrast ventriculogram, but in 12 of these, the three dimensional ejection fraction image showed abnormal septal motion, and in a further 3, abnormal lateral wall motion in addition. In the 12 subjects there was disease of the left anterior descending coronary artery, and in the further 3 there was left circumflex disease. ECG-gated blood pool emission tomography thus provides an accurate quantitative assessment of left ventricular wall motion in three dimensions, and has significant advantages over conventional planar techniques.

  5. Usefulness of Positron Emission Tomography in Patients with Syphilis: A Systematic Review of Observational Studies.

    Science.gov (United States)

    Chen, Jian-Hua; Zheng, Xin; Liu, Xiu-Qin

    2017-05-05

    Diagnosis of syphilis is difficult. Follow-up and therapy evaluation of syphilitic patients are poor. Little is known about positron emission tomography (PET) in syphilis. This review was to systematically review usefulness of PET for diagnosis, disease extent evaluation, follow-up, and treatment response assessment in patients with syphilis. We searched PubMed, EMBASE, SCOPUS, Cochrane Library, Web of Science, ClinicalTrials.gov, and three Chinese databases (SinoMed, Wanfang, and CNKI) for English and Chinese language articles from inception to September 2016. We also collected potentially relevant studies and reviews using a manual search. The search keywords included the combined text and MeSH terms "syphilis" and "positron emission tomography". We included studies that reporting syphilis with a PET scan before and/or after antibiotic treatment. The diagnosis of syphilis was based on serological criteria or dark field microscopy. Outcomes include pre- and post-treatment PET scan, pre- and post-treatment computed tomography, and pre- and post-treatment magnetic resonance imaging. We excluded the articles not published in English or Chinese or not involving humans. Of 258 identified articles, 34 observational studies were included. Thirty-three studies were single-patient case reports and one study was a small case series. All patients were adults. The mean age of patients was 48.3 ± 12.1 years. In primary syphilis, increased fluorodeoxyglucose (FDG) accumulation could be seen at the site of inoculation or in the regional lymph nodes. In secondary syphilis with lung, bone, gastrointestinal involvement, or generalized lymphadenopathy, increased FDG uptake was the most commonly detected changes. In tertiary syphilis, increased glucose metabolic activity, hypometabolic lesions, or normal glucose uptake might be seen on PET. There were five types of PET scans in neurosyphilis. A repeated PET scan after treatment revealed apparent or complete resolution of the

  6. 18F-fluoro-deoxy-glucose-positron emission tomography/computed tomography in diagnosis of head and neck squamous cell carcinoma

    DEFF Research Database (Denmark)

    Rohde, Max; Dyrvig, Anne-Kirstine; Johansen, Jørgen

    2014-01-01

    18F-fluoro-deoxy-glucose-positron emission tomography/computed tomography-scan (PET/CT) is used increasingly for detection of cancer. Precise diagnostic assessment of tumour extension in head and neck squamous cell carcinoma (HNSCC) is of critical importance for ensuring that patients receive...... and qualitatively analysed. Along with the calculated pooled sensitivity and specificity of PET/CT and SCI, bubble- and summary receiver operating characteristics (SROC) plots were created. FINDINGS: Two meta-analyses of diagnostic accuracy were conducted. The first, on PET/CT, included 987 patients distributed...

  7. Potassium Chloride Infusion as the Cause of Altered Bio Distribution of (18)F-Fluorodeoxyglucose on Whole-Body Positron Emission Tomography-Computed Tomography Scan.

    Science.gov (United States)

    Mahajan, Shimpi Madhuri; Natasha, Singh; Sudeshna, Maitra; Pereira, Melvika

    2017-01-01

    (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography-computed tomography is a standard diagnostic imaging tool in many types of cancer. Its physiological in vivo distribution includes the brain, liver, heart, kidneys, and urinary tract at 1 h after tracer injection. Skeletal muscle is known to show variable amounts of (18)F-FDG uptake because it has a relatively high-glucose metabolism. We report a case of a 20-year-old patient with gross (18)F-FDG uptake involving multiple muscle groups and its likely correlation to potassium chloride infusion before (18)F-FDG injection.

  8. Potassium Chloride Infusion as the Cause of Altered Bio Distribution of 18F-Fluorodeoxyglucose on Whole-Body Positron Emission Tomography-Computed Tomography Scan

    Science.gov (United States)

    Mahajan, Shimpi Madhuri; Natasha, Singh; Sudeshna, Maitra; Pereira, Melvika

    2017-01-01

    18F-fluorodeoxyglucose (18F-FDG) positron emission tomography-computed tomography is a standard diagnostic imaging tool in many types of cancer. Its physiological in vivo distribution includes the brain, liver, heart, kidneys, and urinary tract at 1 h after tracer injection. Skeletal muscle is known to show variable amounts of 18F-FDG uptake because it has a relatively high-glucose metabolism. We report a case of a 20-year-old patient with gross 18F-FDG uptake involving multiple muscle groups and its likely correlation to potassium chloride infusion before 18F-FDG injection. PMID:28217028

  9. Primary neuroendocrine carcinoma of breast with liver and bone metastasis detected with fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography.

    Science.gov (United States)

    Kamaleshwaran, Koramadai Karuppusamy; Mohanan, Vyshak; Shibu, Deepu; Radhakrishnan, Edathuruthy Kalarikal; Shinto, Ajit Sugunan

    2014-01-01

    Cases of primary neuroendocrine carcinoma (NEC) of the breast have been reported, though rare. We report the case of a 45-year-old woman presented with jaundice and evaluated to have liver metastasis from neuroendocrine origin. She underwent whole body positron emission tomography/computed tomography, which showed left breast lesion and bone metastasis. Fine-needle aspiration (FNA) of breast revealed a NEC. A diagnosis of a primary NEC of the breast was rendered with hepatic and bone metastasis. She was treated with peptide receptor radionuclide therapy and is on follow-up.

  10. Image findings of monomorphic non-hogdkin lymphoproliferative disorder in a post renal transplant patient diagnosed with fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography.

    Science.gov (United States)

    Kamaleshwaran, Koramadai Karuppusamy; Rajasekar, Thirugnanam; Shibu, Deepu; Radhakrishnan, Edathurthy Kalarikal; Shinto, Ajit Sugunan

    2014-07-01

    Post-transplant lymphoproliferative disorder (PTLD) is a heterogeneous group of lymphoid proliferations caused by immunosuppression after solid organ or bone marrow transplantation. PTLD is categorized by early lesion, polymorphic PTLD and monomorphic PTLD. Fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography (F-18 FDG-PET/CT) scans have clinical significance in the evaluation of PTLD following renal transplantation. We report imaging findings of a monomorphic non-Hodgkin lymphoma, post renal transplant seen on FDG PET/CT in a 32-year-old lactating woman. Whole body FDG- ET/CT demonstrated uptake in right external iliac and inguinal lymph nodes.

  11. Positron emission tomography/magnetic resonance hybrid scanner imaging of cerebral blood flow using 15O-water positron emission tomography and arterial spin labeling magnetic resonance imaging in newborn piglets

    DEFF Research Database (Denmark)

    Andersen, Julie B; Henning, William S; Lindberg, Ulrich

    2015-01-01

    Abnormality in cerebral blood flow (CBF) distribution can lead to hypoxic-ischemic cerebral damage in newborn infants. The aim of the study was to investigate minimally invasive approaches to measure CBF by comparing simultaneous (15)O-water positron emission tomography (PET) and single TI pulsed...... arterial spin labeling (ASL) magnetic resonance imaging (MR) on a hybrid PET/MR in seven newborn piglets. Positron emission tomography was performed with IV injections of 20 MBq and 100 MBq (15)O-water to confirm CBF reliability at low activity. Cerebral blood flow was quantified using a one...

  12. Comparison of Positron Emission Tomography Quantification Using Magnetic Resonance- and Computed Tomography-Based Attenuation Correction in Physiological Tissues and Lesions: A Whole-Body Positron Emission Tomography/Magnetic Resonance Study in 66 Patients.

    Science.gov (United States)

    Seith, Ferdinand; Gatidis, Sergios; Schmidt, Holger; Bezrukov, Ilja; la Fougère, Christian; Nikolaou, Konstantin; Pfannenberg, Christina; Schwenzer, Nina

    2016-01-01

    Attenuation correction (AC) in fully integrated positron emission tomography (PET)/magnetic resonance (MR) systems plays a key role for the quantification of tracer uptake. The aim of this prospective study was to assess the accuracy of standardized uptake value (SUV) quantification using MR-based AC in direct comparison with computed tomography (CT)-based AC of the same PET data set on a large patient population. Sixty-six patients (22 female; mean [SD], 61 [11] years) were examined by means of combined PET/CT and PET/MR (11C-choline, 18F-FDG, or 68Ga-DOTATATE) subsequently. Positron emission tomography images from PET/MR examinations were corrected with MR-derived AC based on tissue segmentation (PET(MR)). The same PET data were corrected using CT-based attenuation maps (μ-maps) derived from PET/CT after nonrigid registration of the CT to the MR-based μ-map (PET(MRCT)). Positron emission tomography SUVs were quantified placing regions of interest or volumes of interest in 6 different body regions as well as PET-avid lesions, respectively. The relative differences of quantitative PET values when using MR-based AC versus CT-based AC were varying depending on the organs and body regions assessed. In detail, the mean (SD) relative differences of PET SUVs were as follows: -7.8% (11.5%), blood pool; -3.6% (5.8%), spleen; -4.4% (5.6%)/-4.1% (6.2%), liver; -0.6% (5.0%), muscle; -1.3% (6.3%), fat; -40.0% (18.7%), bone; 1.6% (4.4%), liver lesions; -6.2% (6.8%), bone lesions; and -1.9% (6.2%), soft tissue lesions. In 10 liver lesions, distinct overestimations greater than 5% were found (up to 10%). In addition, overestimations were found in 2 bone lesions and 1 soft tissue lesion adjacent to the lung (up to 28.0%). Results obtained using different PET tracers show that MR-based AC is accurate in most tissue types, with SUV deviations generally of less than 10%. In bone, however, underestimations can be pronounced, potentially leading to inaccurate SUV quantifications. In

  13. Positron emission tomography: a clinical and biological research tool; La tomographie par emission de positrons: un outil de recherche clinique et biologique

    Energy Technology Data Exchange (ETDEWEB)

    Kotzki, P.O. [Groupe Hospitalo-Universitaire Caremeau, Service de Medecine Nucleaire et de Biophysique Medicale, 30 - Nimes (France)

    2004-07-01

    Medical and biological imaging has undergone a revolution in the past decade. Positron emission tomography (PET) has been developed to visualize biochemical and physiological phenomena in living humans and animals. For instance, blood flow, blood volume, glucose metabolism, amino acid metabolism, can be quantitatively estimated by means of PET with various radioactive tracers. This functional and molecular imaging technique has progressed rapidly from being a research technique in laboratories to a routine clinical imaging modality. The most widely used radiotracer in routine is {sup 18}F-fluorodeoxyglucose ({sup 18}FDG), which is an analogue of glucose. Since glucose metabolism is increased many fold in malignant tumors, PET has a major role in the field of clinical oncology and recently in cardiology and neurology. PET is also a valuable tool to study cerebral or cardiac binding sites and to image the expression of reporter genes in small animals. In this review, we summarize the most recent developments in PET imaging with particular reference to the radiotracers available and their application. (author)

  14. Methods and clinical applications of positron emission tomography in endocrinology. Methodologie et applications cliniques en endocrinologie de la tomographie a emission de positons

    Energy Technology Data Exchange (ETDEWEB)

    Landsheere, C. de; Lamotte, D. (Liege Univ. (BE))

    1990-01-01

    Positron emission tomography (PET) allows to detect in coincidence photons issued from annihilation between positrons and electrons nearby situated. Tomographic detection (plane by plane) and tomographic reconstruction will lead to the quantitation of radioactive distribution per voxel, in the organ of interest. Recent tomographs can acquire simultaneously several transaxial slices, with a high sensitivity and a spatial resolution of 3-5 mm. Commonly used positron emitters have a short half-life: 2, 10, 20 and 110 min for {sup 15}0, {sup 13}N, {sup 11}C and {sup 18}F, respectively. The use of these isotopes requires on line production of radionuclides and synthesis of selected molecules. In endocrinology, PET allows among others to study noninvasively the receptor density of hormonodependent neoplasms such as breast, uterus, prostate tumors and prolactinomas. These last tumors represent a particular entity because of several combined characteristics: high turnover rate of amino acids, high density of dopaminergic receptors and response to bromocriptine (analogue of dopamine inhibiting the secretion of prolactine) in relation to the level of receptors. Because PET permits to evaluate the density of dopaminergic receptors and the metabolism of amino acids, theoretical response of the prolactinoma to bromocriptin can be predicted, the achieved therapeutic efficacy can be estimated and the long-term follow up of tumor growth can be assessed. This example illustrates the clinical value of PET in endocrinology.

  15. Synthesis of novel {sup 68}Ga-labeled amino acid derivatives for positron emission tomography of cancer cells

    Energy Technology Data Exchange (ETDEWEB)

    Shetty, Dinesh [Department of Nuclear Medicine, Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul 110-744 (Korea, Republic of); Cancer Research Institute, Seoul National University College of Medicine, Seoul 110-744 (Korea, Republic of); Department of Radiation Applied Life Science, Seoul National University College of Medicine, Seoul 110-744 (Korea, Republic of); Jeong, Jae Min, E-mail: jmjng@snu.ac.k [Department of Nuclear Medicine, Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul 110-744 (Korea, Republic of); Cancer Research Institute, Seoul National University College of Medicine, Seoul 110-744 (Korea, Republic of); Department of Radiation Applied Life Science, Seoul National University College of Medicine, Seoul 110-744 (Korea, Republic of); Ju, Chang Hwan [Cancer Research Institute, Seoul National University College of Medicine, Seoul 110-744 (Korea, Republic of); Department of Life and Nanopharmaceutical Sciences, Graduate School, Kyung Hee University, Seoul (Korea, Republic of); Lee, Yun-Sang [Department of Nuclear Medicine, Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul 110-744 (Korea, Republic of); Department of Radiation Applied Life Science, Seoul National University College of Medicine, Seoul 110-744 (Korea, Republic of); Jeong, Seo Young [Department of Life and Nanopharmaceutical Sciences, Graduate School, Kyung Hee University, Seoul (Korea, Republic of); Choi, Jae Yeon; Yang, Bo Yeun [Department of Nuclear Medicine, Institute of Radiation Medicine, Seoul National University College of Medicine, Seoul 110-744 (Korea, Republic of); Cancer Research Institute, Seoul National University College of Medicine, Seoul 110-744 (Korea, Republic of); Department of Radiation Applied Life Science, Seoul National University College of Medicine, Seoul 110-744 (Korea, Republic of)

    2010-11-15

    Objectives: We developed amino acid derivatives of 1,4,7,10-tetraazacyclododecane-1,7-diacetic acid (DO2A) and 1,4,7,10-tetraazacyclododecane-1,4,7,-triacetic acid (DO3A) that can be labeled with {sup 68}Ga, and we investigated their basic biological properties. Materials and methods: Alanine derivatives of DO2A and DO3A were synthesized by regiospecific nucleophilic attack of DO2tBu and DO3tBu on the {beta}-position of Boc-L-serine-{beta}-lactone, followed by acid hydrolysis. Also, homoalanine derivatives were synthesized by reacting with the protected bromo derivative of homoalanine, which was synthesized from N-Cbz-L-homoserine lactone. Further catalytic reduction and acid cleavage of protected groups resulted in the required products. All derivatives were labeled with {sup 68}Ga. Cell uptake assays were carried out in Hep3B (human hepatoma) and U87MG (human glioma) cell lines at 37{sup o}C. Positron emission tomography (PET) imaging studies were performed using balb/c mice xenografted with CT-26 (mouse colon cancer). Results: All compounds were labeled with >97% efficiency. According to in vitro studies, the labeled amino acid derivatives showed significantly greater uptakes than the control ({sup 68}Ga 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid) in cancer cells. Small animal PET images for labeled compounds showed high tumor uptake, as well as kidney and bladder uptakes, at 30 min postinjection. {sup 68}Ga-DO3A-homoalanine showed the highest standardized uptake value ratio (3.9{+-}0.3), followed by {sup 68}Ga-DO2A-alanine (3.1{+-}0.2), {sup 68}Ga-DO3A-alanine (2.8{+-}0.2) and {sup 68}Ga-DO2A-homoalanine (2.3{+-}0.2). Conclusion: These derivatives were found to have high labeling efficiencies, high stabilities, high tumor cell uptakes, high tumor/nontumor xenograft uptakes and low nonspecific uptake in normal organs, except for the kidneys. However, the uptake mechanism of these derivatives remains unclear, and uptake via specific amino acid

  16. Use of fluorine-18 fluorodeoxyglucose positron emission tomography in the detection of silent metastases from malignant melanoma

    DEFF Research Database (Denmark)

    Eigtved, A; Andersson, A P; Dahlstrøm, K

    2000-01-01

    Correct staging is crucial for the management and prognosis of patients with malignant melanoma. The aim of this prospective study was to compare staging by whole-body positron emission tomography using fluorine-18 fluorodeoxyglucose (18F-FDG) with staging by conventional methods. Thirty-eight pa......Correct staging is crucial for the management and prognosis of patients with malignant melanoma. The aim of this prospective study was to compare staging by whole-body positron emission tomography using fluorine-18 fluorodeoxyglucose (18F-FDG) with staging by conventional methods. Thirty...

  17. T cell homing to tumors detected by 3D-coordinated positron emission tomography and magnetic resonance imaging

    DEFF Research Database (Denmark)

    Agger, Ralf; Petersen, Mikkel; Petersen, Charlotte Christie

    2007-01-01

    of magnetic resonance imaging with the high sensitivity and spatial accuracy of positron emission tomography. We have used this technique, together with determination of tissue radioactivity, flow cytometry, and microscopy, to characterize and quantitate the specific accumulation of transferred CD8+ T cells...... was determined by flow cytometry each day for 8 consecutive days after adoptive transfer. From low levels 1 day after injection, their number gradually increased until day 5 when an average of 3.3x10(6) SIINFEKL-specific cells per gram tumor tissue was found. By applying the combined positron emission tomography...

  18. Monte-Carlo simulations and image reconstruction for novel imaging scenarios in emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Gillam, John E. [The University of Sydney, Faculty of Health Sciences and The Brain and Mind Centre, Camperdown (Australia); Rafecas, Magdalena, E-mail: rafecas@imt.uni-luebeck.de [University of Lubeck, Institute of Medical Engineering, Ratzeburger Allee 160, 23538 Lübeck (Germany)

    2016-02-11

    Emission imaging incorporates both the development of dedicated devices for data acquisition as well as algorithms for recovering images from that data. Emission tomography is an indirect approach to imaging. The effect of device modification on the final image can be understood through both the way in which data are gathered, using simulation, and the way in which the image is formed from that data, or image reconstruction. When developing novel devices, systems and imaging tasks, accurate simulation and image reconstruction allow performance to be estimated, and in some cases optimized, using computational methods before or during the process of physical construction. However, there are a vast range of approaches, algorithms and pre-existing computational tools that can be exploited and the choices made will affect the accuracy of the in silico results and quality of the reconstructed images. On the one hand, should important physical effects be neglected in either the simulation or reconstruction steps, specific enhancements provided by novel devices may not be represented in the results. On the other hand, over-modeling of device characteristics in either step leads to large computational overheads that can confound timely results. Here, a range of simulation methodologies and toolkits are discussed, as well as reconstruction algorithms that may be employed in emission imaging. The relative advantages and disadvantages of a range of options are highlighted using specific examples from current research scenarios.

  19. Stimulated Emission Computed Tomography (NSECT) images enhancement using a linear filter in the frequency domain

    Energy Technology Data Exchange (ETDEWEB)

    Viana, Rodrigo S.S.; Tardelli, Tiago C.; Yoriyaz, Helio, E-mail: hyoriyaz@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Jackowski, Marcel P., E-mail: mjack@ime.usp.b [University of Sao Paulo (USP), SP (Brazil). Dept. of Computer Science

    2011-07-01

    In recent years, a new technique for in vivo spectrographic imaging of stable isotopes was presented as Neutron Stimulated Emission Computed Tomography (NSECT). In this technique, a fast neutrons beam stimulates stable nuclei in a sample, which emit characteristic gamma radiation. The photon energy is unique and is used to identify the emitting nuclei. The emitted gamma energy spectra can be used for reconstruction of the target tissue image and for determination of the tissue elemental composition. Due to the stochastic nature of photon emission process by irradiated tissue, one of the most suitable algorithms for tomographic reconstruction is the Expectation-Maximization (E-M) algorithm, once on its formulation are considered simultaneously the probabilities of photons emission and detection. However, a disadvantage of this algorithm is the introduction of noise in the reconstructed image as the number of iterations increases. This increase can be caused either by features of the algorithm itself or by the low sampling rate of projections used for tomographic reconstruction. In this work, a linear filter in the frequency domain was used in order to improve the quality of the reconstructed images. (author)

  20. Prospective, blinded trial of whole-body magnetic resonance imaging versus computed tomography positron emission tomography in staging primary and recurrent cancer of the head and neck.

    LENUS (Irish Health Repository)

    O'Neill, J P

    2012-02-01

    OBJECTIVES: To compare the use of computed tomography - positron emission tomography and whole-body magnetic resonance imaging for the staging of head and neck cancer. PATIENTS AND METHODS: From January to July 2009, 15 consecutive head and neck cancer patients (11 men and four women; mean age 59 years; age range 19 to 81 years) underwent computed tomography - positron emission tomography and whole-body magnetic resonance imaging for pre-therapeutic evaluation. All scans were staged, as per the American Joint Committee on Cancer tumour-node-metastasis classification, by two blinded consultant radiologists, in two sittings. Diagnoses were confirmed by histopathological examination of endoscopic biopsies, and in some cases whole surgical specimens. RESULTS: Tumour staging showed a 74 per cent concordance, node staging an 80 per cent concordance and metastasis staging a 100 per cent concordance, comparing the two imaging modalities. CONCLUSION: This study found radiological staging discordance between the two imaging modalities. Whole-body magnetic resonance imaging is an emerging staging modality with superior visualisation of metastatic disease, which does not require exposure to ionising radiation.

  1. Development of radiotracers for imaging NR2B subtype NMDA receptors with positron emission tomography; Developpement de radiotraceurs pour la visualisation des recepteurs NMDA de sous-type NR2B par tomographie par emission de positons

    Energy Technology Data Exchange (ETDEWEB)

    Labas, R

    2007-07-01

    The aim of this thesis was to develop new radioactive tracers for imaging NR2B subtype NMDA receptors with positron emission tomography. Several compounds including 4-(4-fluoro-benzyl)piperidine and presenting interesting in vivo biological properties were the object of a labelling with a positrons emitter atom ({sup 11}C or {sup 18}F)

  2. 68Ga-labeled phage-display selected peptides as tracers for positron emission tomography imaging of Staphylococcus aureus biofilm-associated infections

    DEFF Research Database (Denmark)

    Nielsen, Karin Michaelsen; Kyneb, Majbritt Hauge; Alstrup, Aage Kristian Olsen

    2016-01-01

    INTRODUCTION: Staphylococcus aureus is a major cause of skin and deep-sited infections, often associated with the formation of biofilms. Early diagnosis and initiated therapy is essential to prevent disease progression and to reduce complications that can be serious. Imaging techniques are helpful...... combining anatomical with functional data in order to describe and characterize site, extent and activity of the disease. The purpose of the study was to identify and (68)Ga-label peptides with affinity for S. aureus biofilm and evaluate their potential as bacteria-specific positron emission tomography (PET......) imaging agents. METHODS: Phage-displayed dodecapeptides were selected using an in vitro grown S. aureus biofilm as target. One cyclic (A8) and two linear (A9, A11) dodecapeptides were custom synthesized with 1,4,7,10-tetraazacyclododecane-N,N',N″,N‴-tetraacetic acid (DOTA) conjugated via a lysine linker...

  3. Positron emission tomography (PET) study of the alterations in brain distribution of [{sup 11}C]dethamphetamine in methamphetamine sensitized dog

    Energy Technology Data Exchange (ETDEWEB)

    Mizugaki, Michinao; Nakamura, Hitoshi; Hishinuma, Takanori; Tomioka, Yoshihisa; Ishiwata, Shunji; Suzuki, Hideaki; Ido, Tatsuo; Iwata, Ren; Funaki, Yoshihito; Itoh, Masatoshi; Fujiwara, Takehiko; Yanai, Kazuhiko; Sato, Mitsumoto; Numachi, Yohtaro; Yoshida, Sumiko

    1995-08-01

    [{sup 11}C]Methamphetamine ([{sup 11}C]MAP) was synthesized by an automated on-line [{sup 11}C]methylation system for positron emission tomography (PET) study. We newly produced a MAP sensitized dog by repeated MAP treatment and studied the brain distribution of [{sup 11}C]MAP in the normal and the MAP sensitized dog. The maximal level of accumulation of [{sup 11}C]MAP in the sensitized dog brain was 1.4 times higher than that in the control. No difference was found in the metabolism of MAP between the two conditions. The significant increase of [{sup 11}C]MAP in the MAP sensitized brain indicates that subchronic MAP administration causes some functional change in uptake site of MAP.

  4. Synthesis, radiolabeling and evaluation of novel amine guanidine derivatives as potential positron emission tomography tracers for the ion channel of the N-methyl-d-aspartate receptor.

    Science.gov (United States)

    Klein, Pieter J; Chomet, Marion; Metaxas, Athanasios; Christiaans, Johannes A M; Kooijman, Esther; Schuit, Robert C; Lammertsma, Adriaan A; van Berckel, Bart N M; Windhorst, Albert D

    2016-08-08

    The N-Methyl-d-Aspartate receptor (NMDAR) is involved in many neurological and psychiatric disorders including Alzheimer's disease and schizophrenia. The aim of this study was to develop a positron emission tomography (PET) ligand to assess the bio-availability of the NMDAR ion channel in vivo. A series of tri-N-substituted diarylguanidines was synthesized and their in vitro binding affinities for the NMDAR ion channel assessed in rat forebrain membrane fractions. Compounds 21, 23 and 26 were radiolabeled with either carbon-11 or fluorine-18 and ex vivo biodistribution and metabolite studies were performed in Wistar rats. Biodistribution studies showed high uptake especially in prefrontal cortex and lowest uptake in cerebellum. Pre-treatment with MK-801, however, did not decrease uptake of the radiolabeled ligands. In addition, all three ligands showed fast metabolism. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  5. Diagnostic accuracy of 18F-Fluorodeoxyglucose positron emission tomography in the follow-up of papillary or follicular thyroid cancer.

    NARCIS (Netherlands)

    Hooft, L.; Hoekstra, O.S.; Devillé, W.; Lips, W.; Teule, J.J.; Boers, M.; Tulder, M.W. van

    2001-01-01

    Positron emission tomography with 18F-fluorodeoxyglucose is a relatively new nuclear imaging technique in oncology. We conducted a systematic review to determine the diagnostic accuracy of 18F-fluorodeoxyglucose positron emission tomography in patients suspected of recurrent papillary or follicular

  6. Cerebral blood flow and metabolism for Broca's aphasia using positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Toshiaki

    1987-12-01

    A total of 11 patients with Broca's aphasia (BA) underwent positron emission tomography (PET) with the purpose of investigating the responsible region and the symptomatic flow and metabolism thresholds for BA. Computed tomography (CT) was concurrently performed. In the group of 3 patients undergoing PET with C-11 glucose, both PET and CT provided abnormal findings in the region that is thought to be responsible for BA (Broca's area), including the cortex and subcortex in the anterior region to Sylvian fissure. The Broca's area in the remaining one was shown as low C-11 accumulation area on PET and as isodensity on CT. The second group, consisting of 8 BA patients and 30 control patients without BA, underwent PET using O-15 steady method. PET showed reduction of regional cerebral blood flow (rCBF) and oxygen metabolic rate (rCMRO/sub 2/) in the Broca's area in all BA patients. Computed tomography showed abnormal low density in the Broca's area in 3 patients, and abnormal findings in the basal ganglionic region and subcortex without evidence for abnormal low density in the Broca's area in the other 5 patients. Comparison of rCBF and rCMRO/sub 2/ in BA patients with those in control patients may show the symptomatic thresholds to be 20 - 27 ml100 gmin for rCBF and 2.0 ml100 gmin for rCMRO/sub 2/. (Namekawa, K.).

  7. Professional practice assessment. Pertinence of positron emission tomography clinical indications in oncology; Evaluation des pratiques professionnelles. Pertinence des indications de la tomographie a emission de positons en cancerologie

    Energy Technology Data Exchange (ETDEWEB)

    Le Stanc, E.; Tainturier, C. [Hopital Foch, Service de Medecine Nucleaire, 92 - Suresnes (France); Swaenepoel, J. [Hopital Foch, Cellule Qualite, 92 - Suresnes (France)

    2009-09-15

    Introduction As part of the health care quality and safety policy in France, Professional Practice Assessment (P.P.A.) are mandatory in the health services 'certification' process. We present our study regarding the pertinence of Positron Emission Tomography (PET) indications in oncology. Materials and methods A multidisciplinary task group used the Quick Audit method with two rounds of 100 request forms each. The assessment list of criteria comprised four items of decreasing relevance grading the PET scans clinical indications, which were derived from the three French published guidelines (S.O.R. [F.N.C.L.C.C]., 'Guide du bon usage des examens d'imagerie medicale' [S.F.R.-S.F.M.N.], 'Guide pour la redaction de protocoles pour la TEP au F.D.G. en cancerologie' [S.F.M.N.]) and five additional items: clinical information, patient's body weight, previous treatments dates, diabetes, claustrophobia. Results The first round showed that 68% of the requested scans corresponded to the two most relevant groups of indications (S.O.R. Standards and Options). The request forms were correctly filled in regarding the clinical information, but this was not the case for the other items we tested. Several actions were conducted: dedicated PET request form, availability of the S.O.R. on the hospital intranet, boost of the referring physicians awareness during the multidisciplinary oncology meetings (Reunions de Concertation Pluridisciplinaires RCP). The second round showed a better pertinence of the PET scans indications (75% versus 68%); the patient's body weight was more frequently mentioned on the request form. Discussion This study is an example of P.P.A. in our discipline. It led to an improvement of the oncologic PET scans clinical indications in our hospital. This work is pursued in everyday discussion with the referring clinicians, especially during the RCP. (authors)

  8. Early positron emission tomography response-adapted treatment in stage I and II hodgkin lymphoma

    DEFF Research Database (Denmark)

    André, Marc P.E.; Girinsky, Théodore; Federico, Massimo

    2017-01-01

    Purpose Patients who receive combined modality treatment for stage I and II Hodgkin lymphoma (HL) have an excellent outcome. Early response evaluation with positron emission tomography (PET) scan may improve selection of patients who need reduced or more intensive treatments. Methods We performed...... and II HL. The standard arm consisted of ABVD followed by involved-node radiotherapy (INRT), regardless of ePET result. In the experimental arm, ePET-negative patients received ABVD only (noninferiority design), whereas ePET-positive patients switched to two cycles of bleomycin, etoposide, doxorubicin......, cyclophosphamide, vincristine, procarbazine, and prednisone (BEACOPPesc) and INRT (superiority design). Primary end point was progression-free survival (PFS). Results Of 1,950 randomly assigned patients, 1,925 received an ePET—361 patients (18.8%) were positive. In ePET-positive patients, 5-year PFS improved from...

  9. Nicotine Blocks Brain Estrogen Synthase (Aromatase): In Vivo Positron Emission Tomography Studies in Female Baboons

    Science.gov (United States)

    Biegon, Anat; Kim, Sung-Won; Logan, Jean; Hooker, Jacob M.; Muench, Lisa; Fowler, Joanna S.

    2010-01-01

    Background Cigarette smoking and nicotine have complex effects on human physiology and behavior, including some effects similar to those elicited by inhibition of aromatase, the last enzyme in estrogen biosynthesis. We report the first in vivo primate study to determine whether there is a direct effect of nicotine administration on brain aromatase. Methods Brain aromatase availability was examined with positron emission tomography and the selective aromatase inhibitor [11C]vorozole in six baboons before and after exposure to IV nicotine at .015 and .03 mg/kg. Results Nicotine administration produced significant, dose-dependent reductions in [11C]vorozole binding. The amygdala and preoptic area showed the largest reductions. Plasma levels of nicotine and its major metabolite cotinine were similar to those found in cigarette smokers. Conclusions Nicotine interacts in vivo with primate brain aromatase in regions involved in mood, aggression, and sexual behavior. PMID:20188349

  10. An Application of Micro-channel Plate Photomultiplier Tube to Positron Emission Tomography.

    Science.gov (United States)

    Kim, H; Chen, C-T; Frisch, H; Tang, F; Kao, C-M

    2012-01-01

    We are developing a Time-of-Flight Positron Emission Tomography detector using flat panel micro-channel plate photomultiplier tubes (MCP PMT). The high-speed waveform sampling data acquisition is adopted to exploit the fast time response of MCP PMT efficiently by using transmission-line readout scheme. To demonstrate the feasibility of the proposed detector, prototype detector modules were built using Photonis XP85022 MCP PMT, transmission-line board (TL), and high-speed waveform sampling electronics equipped with DRS4 chips. The MCP/TL module was coupled to single LYSO crystal, and experimental tests have been conducted in a coincidence setup to measure the responses to 511 keV annihilation photon. The details of the prototype module, experimental setup, and the preliminary results are presented and discussed.

  11. Kinetic filtering of [18F]Fluorothymidine in positron emission tomography studies

    Science.gov (United States)

    Gray, Katherine R.; Contractor, Kaiyumars B.; Kenny, Laura M.; Al-Nahhas, Adil; Shousha, Sami; Stebbing, Justin; Wasan, Harpreet S.; Coombes, R. Charles; Aboagye, Eric O.; Turkheimer, Federico E.; Rosso, Lula

    2010-02-01

    [18F]Fluorothymidine (FLT) is a cell proliferation marker that undergoes predominantly hepatic metabolism and therefore shows a high level of accumulation in the liver, as well as in rapidly proliferating tumours. Furthermore, the tracer's uptake is substantial in other organs including the heart. We present a nonlinear kinetic filtering technique which enhances the visualization of tumours imaged with FLT positron emission tomography (FLT-PET). A classification algorithm to isolate cancerous tissue from healthy organs was developed and validated using 29 scan data from patients with locally advanced or metastatic breast cancer. A large reduction in signal from the liver and heart of 80% was observed following application of the kinetic filter, whilst the majority of signal from both primary tumours and metastases was retained. A scan acquisition time of 60 min has been shown to be sufficient to obtain the necessary kinetic data. The algorithm extends utility of FLT-PET imaging in oncology research.

  12. Kinetic filtering of [{sup 18}F]Fluorothymidine in positron emission tomography studies

    Energy Technology Data Exchange (ETDEWEB)

    Gray, Katherine R; Contractor, Kaiyumars B; Kenny, Laura M; Aboagye, Eric O; Turkheimer, Federico E; Rosso, Lula [MRC Clinical Sciences Centre, Imperial College London, Hammersmith Hospital, London (United Kingdom); Al-Nahhas, Adil [Department of Nuclear Medicine, Imperial College NHS Trust, Hammersmith Hospital, London (United Kingdom); Shousha, Sami [Department of Pathology, Imperial College NHS Trust, Charing Cross Hospital, London (United Kingdom); Stebbing, Justin; Wasan, Harpreet S; Coombes, R Charles [Department of Oncology, Faculty of Medicine, Imperial College London, Hammersmith Hospital, London (United Kingdom)], E-mail: eric.aboagye@imperial.ac.uk

    2010-02-07

    [{sup 18}F]Fluorothymidine (FLT) is a cell proliferation marker that undergoes predominantly hepatic metabolism and therefore shows a high level of accumulation in the liver, as well as in rapidly proliferating tumours. Furthermore, the tracer's uptake is substantial in other organs including the heart. We present a nonlinear kinetic filtering technique which enhances the visualization of tumours imaged with FLT positron emission tomography (FLT-PET). A classification algorithm to isolate cancerous tissue from healthy organs was developed and validated using 29 scan data from patients with locally advanced or metastatic breast cancer. A large reduction in signal from the liver and heart of 80% was observed following application of the kinetic filter, whilst the majority of signal from both primary tumours and metastases was retained. A scan acquisition time of 60 min has been shown to be sufficient to obtain the necessary kinetic data. The algorithm extends utility of FLT-PET imaging in oncology research.

  13. Marked reduction of cerebral oxygen metabolism in patients with advanced cirrhosis; A positron emission tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Kawatoko, Toshiharu; Murai, Koichiro; Ibayashi, Setsurou; Tsuji, Hiroshi; Nomiyama, Kensuke; Sadoshima, Seizo; Eujishima, Masatoshi; Kuwabara, Yasuo; Ichiya, Yuichi (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    1992-01-01

    Regional cerebral blood flow (rCBF), cerebral metabolic rate of oxygen (rCMRO{sub 2}), and oxygen extraction fraction (rOEF) were measured using positron emission tomography (PET) in four patients with cirrhosis (two males and two females, aged 57 to 69 years) in comparison with those in five age matched controls with previous transient global amnesia. PET studies were carried out when the patients were fully alert and oriented after the episodes of encephalopathy. In the patients, rCBF tended to be lower, while rCMRO{sub 2} was significantly lowered in almost all hemisphere cortices, more markedly in the frontal cortex. Our results suggest that the brain oxygen metabolism is diffusely impaired in patients with advanced cirrhosis, and the frontal cortex seems to be more susceptible to the systemic metabolic derangements induced by chronic liver disease. (author).

  14. Coronary microvascular dysfunction in women with nonobstructive ischemic heart disease as assessed by positron emission tomography.

    Science.gov (United States)

    Campisi, Roxana; Marengo, Fernando D

    2017-04-01

    Traditional approaches for risk assessment of ischemic heart disease (IHD) are based on the physiological consequences of an epicardial coronary stenosis. Of note, normal coronary arteries or nonobstructive coronary artery disease (CAD) is a common finding in women with signs and symptoms of ischemia. Therefore, assessment of risk based on a coronary stenosis approach may fail in women. Positron emission tomography (PET) quantifies absolute myocardial blood flow (MBF) which may help to elucidate other mechanisms involved such as endothelial dysfunction and alterations in the smooth muscle cell relaxation responsible for IHD in women. The objective of the present review is to describe the current state of the art of PET imaging in assessing IHD in women with nonobstructive CAD.

  15. Transthoracic Doppler echocardiography compared with positron emission tomography for assessment of coronary microvascular dysfunction

    DEFF Research Database (Denmark)

    Michelsen, Marie Mide; Mygind, Naja Dam; Pena, Adam

    2017-01-01

    for measuring coronary microvascular function but has limited availability. We compared TTDE CFVR with PET MBFR in women with angina pectoris and no obstructive coronary artery disease and assessed repeatability of TTDE CFVR. METHODS: From a cohort of women with angina and no obstructive coronary artery......BACKGROUND: Coronary microvascular function can be assessed by transthoracic Doppler echocardiography as a coronary flow velocity reserve (TTDE CFVR) and by positron emission tomography as a myocardial blood flow reserve (PET MBFR). PET MBFR is regarded the noninvasive reference standard...... stenosis at invasive coronary angiography, TTDE CFVR by dipyridamole induced stress and MBFR by rubidium-82 PET with adenosine was successfully measured in 107 subjects. Repeatability of TTDE CFVR was assessed in 10 symptomatic women and in 10 healthy individuals. RESULTS: MBFR was systematically higher...

  16. Injectable silver nanosensors: in vivo dosimetry for external beam radiotherapy using positron emission tomography

    DEFF Research Database (Denmark)

    Christensen, Anders Nymark; Rydhög, J. S.; Søndergaard, Rikke Vicki

    2016-01-01

    Development of safe and efficient radiotherapy routines requires quantification of the delivered absorbed dose to the cancer tissue in individual patients. In vivo dosimetry can provide accurate information about the absorbed dose delivered during treatment. In the current study, a novel silver......-nanosensor formulation based on poly(vinylpyrrolidinone)-coated silver nanoparticles formulated in a gelation matrix composed of sucrose acetate isobutyrate has been developed for use as an in vivo dosimeter for external beam radiotherapy. In situ photonuclear reactions trigger the formation of radioactive (106)Ag......, which enables post treatment verification of the delivered dose using positron emission tomography imaging. The silver-nanosensor was investigated in a tissue equivalent thorax phantom using clinical settings and workflow for both standard fractionated radiotherapy (2 Gy) and stereotactic radiotherapy...

  17. Carbon-11 and Fluorine-18 Labeled Amino Acid Tracers for Positron Emission Tomography Imaging of Tumors

    Directory of Open Access Journals (Sweden)

    Aixia Sun

    2018-01-01

    Full Text Available Tumor cells have an increased nutritional demand for amino acids (AAs to satisfy their rapid proliferation. Positron-emitting nuclide labeled AAs are interesting probes and are of great importance for imaging tumors using positron emission tomography (PET. Carbon-11 and fluorine-18 labeled AAs include the [1-11C] AAs, labeling alpha-C- AAs, the branched-chain of AAs and N-substituted carbon-11 labeled AAs. These tracers target protein synthesis or amino acid (AA transport, and their uptake mechanism mainly involves AA transport. AA PET tracers have been widely used in clinical settings to image brain tumors, neuroendocrine tumors, prostate cancer, breast cancer, non-small cell lung cancer (NSCLC and hepatocellular carcinoma. This review focuses on the fundamental concepts and the uptake mechanism of AAs, AA PET tracers and their clinical applications.

  18. An objective evaluation framework for segmentation techniques of functional positron emission tomography studies

    CERN Document Server

    Kim, J; Eberl, S; Feng, D

    2004-01-01

    Segmentation of multi-dimensional functional positron emission tomography (PET) studies into regions of interest (ROI) exhibiting similar temporal behavior is useful in diagnosis and evaluation of neurological images. Quantitative evaluation plays a crucial role in measuring the segmentation algorithm's performance. Due to the lack of "ground truth" available for evaluating segmentation of clinical images, automated segmentation results are usually compared with manual delineation of structures which is, however, subjective, and is difficult to perform. Alternatively, segmentation of co-registered anatomical images such as magnetic resonance imaging (MRI) can be used as the ground truth to the PET segmentation. However, this is limited to PET studies which have corresponding MRI. In this study, we introduce a framework for the objective and quantitative evaluation of functional PET study segmentation without the need for manual delineation or registration to anatomical images of the patient. The segmentation ...

  19. Nicotine Blocks Brain Estrogen Synthase (Aromatase): In Vivo Positron Emission Tomography Studies in Female Baboons

    Energy Technology Data Exchange (ETDEWEB)

    Biegon, A.; Biegon, A.; Kim, S.-W.; Logan, J.; Hooker, J.M.; Muench, L.; Fowler, J.S.

    2010-01-12

    Cigarette smoking and nicotine have complex effects on human physiology and behavior, including some effects similar to those elicited by inhibition of aromatase, the last enzyme in estrogen biosynthesis. We report the first in vivo primate study to determine whether there is a direct effect of nicotine administration on brain aromatase. Brain aromatase availability was examined with positron emission tomography and the selective aromatase inhibitor [{sup 11}C]vorozole in six baboons before and after exposure to IV nicotine at .015 and .03 mg/kg. Nicotine administration produced significant, dose-dependent reductions in [{sup 11}C]vorozole binding. The amygdala and preoptic area showed the largest reductions. Plasma levels of nicotine and its major metabolite cotinine were similar to those found in cigarette smokers. Nicotine interacts in vivo with primate brain aromatase in regions involved in mood, aggression, and sexual behavior.

  20. Technetium-99m hexamethylpropylene amine oxime single photon emission tomography in febrile convulsions.

    Science.gov (United States)

    Dierckx, R A; Melis, K; Dom, L; Janssens, G; Luysterborgh, E; De Deyn, P P; Vandevivere, J

    1992-01-01

    We report our initial experience with technetium-99m hexamethyl propylene amine oxime (99mTC-HMPAO) brain single photon emission tomography (SPET) in the investigation of 19 children presenting with febrile convulsions. Two patients with complex febrile convulsions showed focal SPET lesions contralateral to the neurological deficit. However, in 9 out of 17 patients with simple febrile convulsions, focally disturbed perfusion was shown. In 4 out of 6 patients with electroencephalogram (EEG) abnormalities on admittance, SPET revealed at least 2 focal lesions. The temporofrontal region was the one most commonly involved. The SPET findings presented here also suggest a temporal relationship with the febrile convulsions, with markedly fewer lesions if examined after 12 days. In our initial experience, perfusion SPET did not show any particular pattern helpful in the differential diagnosis of the child presenting with febrile convulsions. Physiopathologically, our findings may support the hypothesis that brain tissue is regionally more vulnerable to fever, in patients presenting with febrile convulsions.

  1. Speech processing system demonstrated by positron emission tomography (PET). A review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Hirano, Shigeru; Naito, Yasushi; Kojima, Hisayoshi [Kyoto Univ. (Japan)

    1996-03-01

    We review the literature on speech processing in the central nervous system as demonstrated by positron emission tomography (PET). Activation study using PET has been proved to be a useful and non-invasive method of investigating the speech processing system in normal subjects. In speech recognition, the auditory association areas and lexico-semantic areas called Wernicke`s area play important roles. Broca`s area, motor areas, supplementary motor cortices and the prefrontal area have been proved to be related to speech output. Visual speech stimulation activates not only the visual association areas but also the temporal region and prefrontal area, especially in lexico-semantic processing. Higher level speech processing, such as conversation which includes auditory processing, vocalization and thinking, activates broad areas in both hemispheres. This paper also discusses problems to be resolved in the future. (author) 42 refs.

  2. Design And Development Of A Mammary And Axillary Region Positron Emission Tomography System (maxpet)

    CERN Document Server

    Doshi, N K

    2000-01-01

    Breast cancer is the second leading cause of cancer death in women. Currently, mammography and physical breast examination, both non-invasive techniques, provide the two most effective methods available for screening potential breast cancer patients. During the management of patients, however, several invasive techniques such as axillary lymph node dissection, core biopsies and lumpectomies, are utilized to determine the stage or malignancy of the disease with significant cost and morbidity associated with them. Positron Emission Tomography (PET), using [F-18] fluorodeoxyglucose (FDG) tracer is a sensitive and non-invasive imaging modality that may be a cost-effective alternative to certain invasive procedures. In this project we have developed a low cost, high performance, dedicated PET camera (maxPET) for mammary and axillary region imaging. The system consists of two 15x15 cm2 planar scintillation detector arrays composed of modular detectors operating in coincidence. The modular detectors are comprised of...

  3. Interstitial brachytherapy for liver metastases and assessment of response by positron emission tomography: a case report

    Directory of Open Access Journals (Sweden)

    Goura Kishor Rath

    2010-10-01

    Full Text Available For liver metastases (LM, image guided percutaneous ablative procedures such as radiofrequency ablation (RFA, laser induced thermal therapy (LITT and trans-arterial chemo-embolisation (TACE are increasingly being used because they are relatively safer, less invasive and equally effective. CT scan guided interstitial brachytherapy (IBT with a single large dose of radiation by high dose rate (HDR brachytherapy is a novel technique of treating LM and has shown good results. Positron emission tomography (PET scan may provide better information for assessing the response toIBT procedures. We hereby report a case of LM that was treated by HDR IBT and PET scan was done in addition to CT scan for assessing the response.

  4. Regional cerebral glucose metabolic rate in human sleep assessed by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Buchsbaum, M.S.; Wu, J.; Hazlett, E.; Sicotte, N.; Bunney, W.E. Jr. (Univ. of California, Irvine (USA)); Gillin, J.C. (Univ. of California, San Diego (USA))

    1989-01-01

    The cerebral metabolic rate of glucose was measured during nighttime sleep in 36 normal volunteers using positron emission tomography and fluorine-18-labeled 2-deoxyglucose (FDG). In comparison to waking controls, subjects given FDG during non-rapid eye movement (NREM) sleep showed about a 23% reduction in metabolic rate across the entire brain. This decrease was greater for the frontal than temporal or occipital lobes, and greater for basal ganglia and thalamus than cortex. Subjects in rapid eye movement (REM) sleep tended to have higher cortical metabolic rates than walking subjects. The cingulate gyrus was the only cortical structure to show a significant increase in glucose metabolic rate in REM sleep in comparison to waking. The basal ganglia were relatively more active on the right in REM sleep and symmetrical in NREM sleep.

  5. Parametric imaging via kinetics-induced filter for dynamic positron emission tomography.

    Science.gov (United States)

    Bian, Zhaoying; Huang, Jing; Lu, Lijun; Ma, Jianhua; Zeng, Dong; Feng, Qianjin; Chen, Wufan

    2013-01-01

    Due to the noisy measurement of the voxel-wise time activity curve (TAC), parametric imaging for dynamic positron emission tomography (PET) is a challenging task. To address this problem, some spatial filters, such as Gaussian filter, bilateral filter, wavelet-based filter, and so on, are often performed to reduce the noise of each frame. However, these filters usually just consider local properties of each frame without exploring the kinetic information. In this paper, aiming to improve the quantitative accuracy of parametric imaging, we present a kinetics-induced filter to lower the noise of dynamic PET images by incorporating the kinetic information. The present kinetics-induced filter is designed via the similarity between voxel-wise TACs under the framework of bilateral filter. Experimental results with a simulation study demonstrate that the present kinetics-induced filter can achieve noticeable gains than other existing methods for parametric images in terms of quantitative accuracy measures.

  6. Hot water epilepsy: Phenotype and single photon emission computed tomography observations.

    Science.gov (United States)

    Patel, Mehul; Satishchandra, Parthasarathy; Aravinda, Hanumanthapura; Bharath, Rose D; Sinha, Sanjib

    2014-10-01

    We studied the anatomical correlates of reflex hot water epilepsy (HWE) using multimodality investigations viz. magnetic resonance imaging (MRI), electroencephalography (EEG), and single photon emission computed tomography (SPECT). Five men (mean age: 27.0 ΁ 5.8 years) with HWE were subjected to MRI of brain, video-EEG studies, and SPECT scan. These were correlated with phenotypic presentations. Seizures could be precipitated in three patients with pouring of hot water over the head and semiology of seizures was suggestive of temporal lobe epilepsy. Ictal SPECT showed hyperperfusion in: left medial temporal - one, left lateral temporal - one, and right parietal - one. Interictal SPECT was normal in all five patients and did not help in localization. MRI and interictal EEG was normal in all the patients. The clinical and SPECT studies suggested temporal lobe as the seizure onset zone in some of the patients with HWE.

  7. PET and paediatrics; La tomographie par emission de positons (ou PET scan) en pediatrie

    Energy Technology Data Exchange (ETDEWEB)

    Boddaert, N. [Necker Enfants Malades, AP-HP, Serv Radiol Pediat, Paris (France); Ribeiro, M.J. [CEA, DSV, I2BM, Serv Hosp Frederic Joliot, F-91406 Orsay (France)

    2008-07-01

    Positon emission tomography (PET scan) is a functional imagery technique.As in scintigraphy, a radioactive tracer is administrated to the patient and its distribution into the organism is detected by a tomograph or a PET scanner. The nuclear medicine techniques which use radioactive tracers allow to obtain an imagery of the regional metabolism of glucose, blood flow or of different neurotransmitters. The PET-TDM (tomodensitometry) is an hybrid imagery system which associates a PET to a multi-bars scanner (4 to 64 bars). The use of hybrid imagery systems allows an anatomic register of the metabolic anomalies or others, as well as the adjustment of the attenuation of the emitted particles. (O.M.)

  8. Asymptomatic Thymic Carcinoma With Solitary Hepatic Metastasis Detected by Fluorodeoxyglucose Positron Emission Tomography

    Directory of Open Access Journals (Sweden)

    Lien-Yen Wang

    2009-08-01

    Full Text Available Thymic carcinoma is a rare anterior mediastinal malignancy. Most patients present initially with chest pain, cough or dyspnea. Asymptomatic patients account for less than one third of the total cases. Thymic carcinoma is aggressive and tends to metastasize to the lymph nodes, lungs, and bones, and less commonly to the liver, spleen, brain, and adrenal glands. We present a 49-year-old man who received abdominal ultrasound and magnetic resonance imaging for a health checkup, during which, a necrotic hepatic tumor was found incidentally. Fluorodeoxyglucose (FDG positron emission tomography was performed to search for the primary site of malignancy, and lobulated FDG hypermetabolic lesions in the anterior mediastinum were found. The diagnosis of thymic carcinoma with liver metastasis was then confirmed after morphological and immunohistochemical studies of hepatic and mediastinal biopsy specimens.

  9. Short time bacterial endotoxins test for positron emission tomography by means of positively charged filters

    Energy Technology Data Exchange (ETDEWEB)

    Nakazawa, Nobuhiro; Wakita, Kazuo [Nishijin Hospital, Kyoto (Japan); Mineura, Katsuyoshi [Kyoto Prefectural Univ. of Medicine (Japan)] (and others)

    2002-11-01

    Positron emission tomography (PET) radiotracers have very short physical half-lives. It is hard to complete a bacterial endotoxins test prior to release from medical institutes. For endotoxin quantitative determination, limulus amebocyte lysate (LAL) reagent and kinetic-turbidimetry system were previously developed. We investigated the possibility of a short time test by means of positively charged filters. As a result of this study, the effects of positively charged filters on endotoxin removal were over 99.5% for [{sup 18}F]FDG and [{sup 18}F]NaF, which were contaminated with the indicated concentration of endotoxin. Combining this filter and the kinetic-turbidimetric method, it was possible to complete a bacterial endotoxins test in 5 min prior to the patient's administration. This test should be required prior to release for PET radiopharmaceutical quality control. It has been suggested that this combination is a good method for this purpose. (author)

  10. Recommendations for measurement of tumour vascularity with positron emission tomography in early phase clinical trials

    Energy Technology Data Exchange (ETDEWEB)

    Aboagye, Eric O.; Kenny, Laura M.; Myers, Melvyn [Imperial College London, Department of Surgery and Cancer, Faculty of Medicine, London (United Kingdom); Gilbert, Fiona J. [University of Cambridge, Radiology Department, Cambridge (United Kingdom); Fleming, Ian N. [University of Aberdeen, NCRI PET Research Network, Aberdeen Bioimaging Centre, Aberdeen (United Kingdom); Beer, Ambros J. [Technische Universitaet Munchen, Klinikum rechts der Isar, Department of Nuclear Medicine, Munich (Germany); Cunningham, Vincent J. [University of Aberdeen, Institute of Medical Sciences, Aberdeen (United Kingdom); Marsden, Paul K. [St. Thomas' Hospital, Division of Imaging Sciences, PET Imaging Centre, London (United Kingdom); Visvikis, Dimitris [INSERM National Institute of Health and Clinical Sciences LaTIM, CHU Morvan, Brest (France); Gee, Antony D. [St. Thomas' Hospital, Division of Imaging Sciences, The Rayne Institute, London (United Kingdom); Groves, Ashley M. [University College London, University College Hospital, Institute of Nuclear Medicine, London (United Kingdom); Cook, Gary J. [St. Thomas' Hospital, KCL Division of Imaging, Sciences and Biomedical Engineering, PET Imaging Centre, London (United Kingdom); Kinahan, Paul E. [University of Washington, 222 Old Fisheries Center (FIS), Box 357987, Seattle, WA (United States); Clarke, Larry [Cancer Imaging Program, Imaging Technology Development Branch, Rockville, MD (United States)

    2012-07-15

    The evaluation of drug pharmacodynamics and early tumour response are integral to current clinical trials of novel cancer therapeutics to explain or predict long term clinical benefit or to confirm dose selection. Tumour vascularity assessment by positron emission tomography could be viewed as a generic pharmacodynamic endpoint or tool for monitoring response to treatment. This review discusses methods for semi-quantitative and quantitative assessment of tumour vascularity. The radioligands and radiotracers range from direct physiological functional tracers like [{sup 15}O]-water to macromolecular probes targeting integrin receptors expressed on neovasculature. Finally we make recommendations on ways to incorporate such measurements of tumour vascularity into early clinical trials of novel therapeutics. (orig.)

  11. Greater left cerebral hemispheric metabolism in bulimia assessed by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Wu, J.C.; Hagman, J.; Buchsbaum, M.S.; Blinder, B.; Derrfler, M.; Tai, W.Y.; Hazlett, E.; Sicotte, N. (Univ. of California, Irvine (USA))

    1990-03-01

    Eight women with bulimia and eight age- and sex-matched normal control subjects were studied with positron emission tomography using (18F)-fluorodeoxyglucose (FDG) as a tracer of brain metabolic rate. Subjects performed a visual vigilance task during FDG uptake. In control subjects, the metabolic rate was higher in the right hemisphere than in the left, but patients with bulimia did not have this normal asymmetry. Lower metabolic rates in the basal ganglia, found in studies of depressed subjects, and higher rates in the basal ganglia, reported in a study of anorexia nervosa, were not found. This is consistent with the suggestion that bulimia is a diagnostic grouping distinct from these disorders.

  12. Metabolic and hemodynamic evaluation of brain metastases from small cell lung cancer with positron emission tomography

    DEFF Research Database (Denmark)

    Lassen, U; Andersen, P; Daugaard, G

    1998-01-01

    Brain metastases from small cell lung cancer respond to chemotherapy, but response duration is short and the intracerebral concentration of chemotherapy may be too low because of the characteristics of the blood-brain barrier. Positron emission tomography has been applied in a variety of tumors...... for studies of metabolic and hemodynamic features. This study was performed to determine regional cerebral metabolic rate of glucose (rCMRglu), regional cerebral blood flow (rCBF), and regional cerebral blood volume (rCBV) in brain metastases from small cell lung cancer and the surrounding brain. Tumor r......CMRglu, rCBF, and rCBV exerted a broad variability, but were higher than the corresponding values in white matter and higher than or similar to those of gray matter. Tumor rCMRglu and rCBF were highly correlated (P

  13. Hot water epilepsy: Phenotype and single photon emission computed tomography observations

    Directory of Open Access Journals (Sweden)

    Mehul Patel

    2014-01-01

    Full Text Available We studied the anatomical correlates of reflex hot water epilepsy (HWE using multimodality investigations viz. magnetic resonance imaging (MRI, electroencephalography (EEG, and single photon emission computed tomography (SPECT. Five men (mean age: 27.0 ΁ 5.8 years with HWE were subjected to MRI of brain, video-EEG studies, and SPECT scan. These were correlated with phenotypic presentations. Seizures could be precipitated in three patients with pouring of hot water over the head and semiology of seizures was suggestive of temporal lobe epilepsy. Ictal SPECT showed hyperperfusion in: left medial temporal - one, left lateral temporal - one, and right parietal - one. Interictal SPECT was normal in all five patients and did not help in localization. MRI and interictal EEG was normal in all the patients. The clinical and SPECT studies suggested temporal lobe as the seizure onset zone in some of the patients with HWE.

  14. Monitoring variables affecting positron emission tomography measurements of cerebral blood flow in anaesthetized pigs

    DEFF Research Database (Denmark)

    Alstrup, Aage Kristian Olsen; Zois, Nora Elisabeth; Simonsen, Mette

    female pigs. Results: We found that low blood pH, high arterial carbon dioxide tension (PaCO2), high heart rate, high body temperature and long anaesthesia time are associated with high CBF in anaesthetized pigs. No associations were noted between CBF and low arterial oxygen tension, haematocrit......, systolic and diastolic blood pressure. Conclusions: Our observations indicate that monitoring of pH, PaCO2, heart rate and body temperature are crucial for maintaining stable levels of CBF and thus optimizing PET imaging of molecular mechanisms in the brain of living pig. Furtermore, anaesthesia length......Background: Positron emission tomography (PET) imaging of anaesthetised pig brains is a useful tool in neuroscience. Stable cerebral blood flow (CBF) is essential for PET, since variations can affect the kinetics of several radiotracers. However, the impact of physiological factors regulating CBF...

  15. 18F-fluorodeoxyglucose positron emission tomography might be useful for diagnosis of hepatic amyloidosis

    Directory of Open Access Journals (Sweden)

    Tawada A

    2014-06-01

    Full Text Available Akinobu Tawada,1 Tatsuo Kanda,1 Takashi Oide,2 Toshio Tsuyuguchi,1 Fumio Imazeki,1,3 Yukio Nakatani,2 Osamu Yokosuka11Department of Gastroenterology, 2Department of Diagnostic Pathology, Chiba University Hospital, Chuo-ku, Chiba, Japan; 3Safety and Health Organization, Chiba University, Inage-ku, Chiba, JapanAbstract: We report on a woman with hepatic involvement of primary systemic (immunoglobulin light chain, AL amyloidosis. Her diagnosis was confirmed by liver biopsy. Clinical symptoms of hepatic amyloidosis are generally mild at its first stage, with most frequent findings being hepatomegaly and alkaline phosphatase elevation. Recent advances in the understanding of the pathophysiology of systemic amyloidosis have made several treatments available. However, its prognosis is occasionally poor. Because liver biopsy is not always safe, other modalities for the diagnosis are needed. Of interest was that fluorodeoxyglucose (FDG uptake into the liver was observed, compared with that into the spleen, in this patient, indicating that FDG positron emission tomography and computed tomography might be useful for the diagnosis of hepatic amyloidosis with mild liver dysfunction.Keywords: amyloidosis, diagnosis, hepatic involvement, FDG PET

  16. Positron Emission Tomography for Serial Imaging of the Contused Adult Rat Spinal Cord

    Directory of Open Access Journals (Sweden)

    Rishi D.S. Nandoe Tewarie

    2010-03-01

    Full Text Available We investigated whether small-animal positron emission tomography (PET could be used in combination with computed tomography (CT imaging techniques for longitudinal monitoring of the injured spinal cord. In adult female Sprague-Dawley rats (n = 6, the ninth thoracic (T9 spinal cord segment was exposed by laminectomy and subsequently contused using the Infinite Horizon impactor (Precision System and Instrumentation, Lexington, KY at 225 kDyn. In control rats (n = 4, the T9 spinal cord was exposed by laminectomy but not contused. At 0.5 hours and 3, 7, and 21 days postinjury, 2-[18F]fluoro-2-deoxy-d-glucose ([18F]FDG was given intravenously followed 1 hour later by sequential PET and CT. Regions of interest (ROIs at T9 (contused and T6 (uninjured spinal cord segments were manually defined on CT images and aided by fiduciary markers superimposed onto the coregistered PET images. Monte Carlo simulation revealed that about 33% of the activity in the ROIs was due to spillover from adjacent hot areas. A simulation-based partial-volume compensation (PVC method was developed and used to correct for this spillover effect. With PET-CT, combined with PVC, we were able to serially measure standardized uptake values of the T9 and T6 spinal cord segments and reveal small, but significant, differences. This approach may become a tool to assess the efficacy of spinal cord repair strategies.

  17. Positron Emission Tomography-Determined Hyperemic Flow, Myocardial Flow Reserve, and Flow Gradient-Quo Vadis?

    Science.gov (United States)

    Leucker, Thorsten M; Valenta, Ines; Schindler, Thomas Hellmut

    2017-01-01

    Positron emission tomography/computed tomography (PET/CT) applied with positron-emitting flow tracers such as (13)N-ammonia and (82)Rubidium enables the quantification of both myocardial perfusion and myocardial blood flow (MBF) in milliliters per gram per minute for coronary artery disease (CAD) detection and characterization. The detection of a regional myocardial perfusion defect during vasomotor stress commonly identifies the culprit lesion or most severe epicardial narrowing, whereas adding regional hyperemic MBFs, myocardial flow reserve (MFR), and/or longitudinal flow decrease may also signify less severe but flow-limiting stenosis in multivessel CAD. The addition of regional hyperemic flow parameters, therefore, may afford a comprehensive identification and characterization of flow-limiting effects of multivessel CAD. The non-specific origin of decreases in hyperemic MBFs and MFR, however, prompts an evaluation and interpretation of regional flow in the appropriate context with the presence of obstructive CAD. Conversely, initial results of the assessment of a longitudinal hyperemic flow gradient suggest this novel flow parameter to be specifically related to increases in CAD caused epicardial resistance. The concurrent assessment of myocardial perfusion and several hyperemic flow parameters with PET/CT may indeed open novel avenues of precision medicine to guide coronary revascularization procedures that may potentially lead to a further improvement in cardiovascular outcomes in CAD patients.

  18. 18F-FDG positron emission tomography in oncology: main indications.

    Science.gov (United States)

    Vercher-Conejero, J L; Gámez Cenzano, C

    2016-01-01

    The development of molecular and functional imaging with new imaging techniques such as computed tomography, magnetic resonance imaging, and positron emission tomography (PET) among others, has greatly improved the detection of tumors, tumor staging, and the detection of possible recurrences. Furthermore, the combination of these different imaging modalities and the continual development of radiotracers for PET have advanced our understanding and knowledge of the different pathophysiological processes in cancer, thereby helping to make treatment more efficacious, improving patients' quality of life, and increasing survival. PET is one of the imaging techniques that has attracted the most interest in recent years for its diagnostic capabilities. Its ability to anatomically locate pathologic foci of metabolic activity has revolutionized the detection and staging of many tumors, exponentially broadening its potential indications not only in oncology but also in other fields such as cardiology, neurology, and inflammatory and infectious diseases. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Prospective evaluation of positron emission tomography in the preoperative staging of esophageal carcinoma.

    Science.gov (United States)

    Kneist, Werner; Schreckenberger, Mathias; Bartenstein, Peter; Menzel, Christian; Oberholzer, Katja; Junginger, Theodor

    2004-10-01

    Positron emission tomography (PET) is a useful tool in the selection of patients with esophageal cancer who may not benefit from esophageal resection. Case series. Tertiary care hospital. Eighty-one patients with newly diagnosed esophageal cancer who underwent PET and computer tomography (CT) of the chest and abdomen (and of the neck in 45 patients) within 45 days were included. We calculated the sensitivity and specificity in detecting metastatic sites on the basis of 31 histologically verified lesions. In addition to results obtained on CT, the information provided by PET was evaluated with a view to the choice of management strategies. The PET findings had a higher specificity (89% vs 11%) but a lower sensitivity (38% vs 63%) than CT findings in the detection of metastatic sites. The CT results showed greater agreement with histopathological findings than did PET results. In 8 patients (10%), PET detected distant metastases that were not identified with CT. In 4 patients (5%), PET detected bone metastases only, but in all of these patients metastases in other locations were detected by CT. Although PET led to upstaging (M1) in 2 patients (2%), it did not enable the exclusion of esophageal resection. Preoperative PET was not characterized by greater accuracy in the detection of metastatic sites previously identified by CT. Therefore, PET did not lead to a change in the indication for esophagectomy. An increase in the sensitivity and the combined use of CT and PET may lead to new indications for this staging procedure.

  20. An unusual presentation of a sarcoidosis that mimicked lymphatic metastatize non small cell lung carcinoma in positron emission tomography: a case report

    OpenAIRE

    Dzemali, Omer; Papadopoulos, Nestoras; Bakhtiary, Farhad; Therapidis, Panagiotis; Kleine, Peter

    2009-01-01

    In the last decade, several sophisticated and accurate imaging methods such as positron emission tomography have been developed in order to evaluate malignant potential in enlarged mediastinal lymph nodes. This case illustrates an unusual presentation of sarcoidosis that mimicked lymphatic metastases of non small cell lung carcinoma. The reported high specificity and sensitivity of positron emission tomography-Computer Tomography regarding mediastinal staging could lead in same cases of false...

  1. Prediction of arrhythmic events with positron emission tomography: PAREPET study design and methods.

    Science.gov (United States)

    Fallavollita, James A; Luisi, Andrew J; Michalek, Suzanne M; Valverde, Arturo M; deKemp, Robert A; Haka, Michael S; Hutson, Alan D; Canty, John M

    2006-08-01

    In medically-treated patients with ischemic cardiomyopathy, myocardial viability is associated with a worse prognosis than scar. The risk is especially great with hibernating myocardium (chronic regional dysfunction with reduced resting flow), and the excess mortality appears to be due to sudden cardiac death (SCD). Hibernating myocardium also results in sympathetic nerve dysfunction, which has been independently associated with risk of SCD. PAREPET is a prospective, observational cohort study funded by NHLBI. It is designed to determine whether hibernating myocardium and/or inhomogeneity of sympathetic innervation by positron emission tomography imaging identifies patients with ischemic cardiomyopathy who are at high risk for SCD and cardiovascular mortality. Patients with documented ischemic cardiomyopathy, an ejection fraction of emission tomography to quantify resting perfusion (13N-ammonia), norepinephrine uptake as an index of sympathetic innervation (11C-meta-hydroxyephedrine), and metabolic viability (18F-2-deoxyglucose during glucose-insulin clamp). The development of SCD or cardiovascular mortality will be determined by telephone follow-up every three months. In patients with an implantable cardiac defibrillator, appropriate device discharge will be considered a surrogate for SCD. The PAREPET study will prospectively determine whether the amount of viable dysfunction myocardium and/or cardiac sympathetic dysinnervation is associated with the risk of SCD. It is anticipated that the

  2. Measurement of lower limb blood flow in patients with neurogenic claudication using positron emission tomography.

    Science.gov (United States)

    Keenan, G F; Ashcroft, G P; Roditi, G H; Hutchison, J D; Evans, N T; Mikecz, P; Chaloner, F; Dodd, M; Leonard, C; Porter, R W

    1995-02-15

    Ten subjects (seven with neurogenic claudication and three control subjects) underwent examination of lower limb muscle blood flow before and after exercise using positron emission tomography. To investigate the hypothesis that lower limb muscle ischemia was the origin of symptoms in neurogenic claudication. Patients with neurogenic claudication secondary to spinal stenosis experience lower limb discomfort after exercise similar to that of ischemic claudication. However, they do not have clinical evidence of peripheral vascular disease. The authors postulated that the lower limb discomfort in patients with neurogenic claudication may arise from muscle ischemia due to inadequate dilatation of arterioles in response to exercise, this itself arising secondary to sympathetic dysfunction due to spinal stenosis. Using O15-labeled water and positron emission tomography measured thigh and leg muscle blood flow response to exercise bilaterally in seven patients with unilateral neurogenic claudication and three control subjects were measured. The average values obtained for mid-thigh and mid-calf muscle perfusion at rest were 2.57 ml/min/100 g tissue (2.23-3.90) and 2.39 ml/min/100 g tissue (2.03-3.46), respectively. The average values obtained from mid-thigh and mid-calf perfusion after exercise were 4.41 ml/min/100 g tissue (2.8-6.0) and 4.87 ml/min/100 g (2.2-11.7). We found no difference in muscle perfusion between symptomatic and asymptomatic limbs in this group of patients. These studies suggest that muscle ischemia is not the origin of symptoms in most patients with neurogenic claudication.

  3. Positron emission tomography demonstrates that coronary sinus retroperfusion can restore regional myocardial perfusion and preserve metabolism

    Energy Technology Data Exchange (ETDEWEB)

    O' Byrne, G.T.; Nienaber, C.A.; Miyazaki, A.; Araujo, L.; Fishbein, M.C.; Corday, E.; Schelbert, H.R. (Department of Radiological Sciences, University of California, Los Angeles School of Medicine (USA))

    1991-07-01

    Positron emission tomography was used to image blood flow and metabolic tracers in risk zone myocardium after left anterior descending coronary artery occlusion during synchronized coronary venous retroperfusion. Six control and seven intervention open chest dogs had occlusion of the mid left anterior descending coronary artery. Synchronized retroperfusion commenced 25 min later. Flow tracers (rubidium-82 and nitrogen-13 ammonia) were injected retrogradely. Three hours after coronary occlusion, fluorine-18 (F-18) deoxyglucose uptake in the control and treatment groups was compared. At 200 min of occlusion, infarct size was assessed. Retrograde flow tracer uptake was observed in the risk zone in the seven intervention dogs. Fluorine-18 deoxyglucose uptake in the risk zone was increased in five of the six intervention dogs but was reduced in five of the six control dogs. The risk zone to normal zone F-18 deoxyglucose count ratio was higher in the intervention than the control group (1.13 {plus minus} 0.39 vs. 0.59 {plus minus} 0.51; p less than 0.05). The endocardial subsegment risk zone to normal zone F-18 deoxyglucose count ratio was also significantly higher in the intervention group. Percent infarction in the risk zone was 70% lower in the group treated with synchronized retroperfusion than in the control group (18.4 {plus minus} 22.6% vs. 61.2 {plus minus} 25.4%; p less than 0.02). Thus, positron emission tomography revealed that retroperfusion could deliver oxygenated blood and maintain metabolism in risk zone myocardium. Infarct size was limited to 30% of that of control. In acute closure of the left anterior descending coronary artery, synchronized retroperfusion might be considered for maintaining viability of the jeopardized myocardium if the artery cannot be reopened rapidly.

  4. Positron emission tomography in pebble beds. Part 1: Liquid particle deposition

    Energy Technology Data Exchange (ETDEWEB)

    Barth, T., E-mail: t.barth@hzdr.de [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics (IFD), Bautzner Landstraße 400, 01328 Dresden (Germany); Ludwig, M. [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics (IFD), Bautzner Landstraße 400, 01328 Dresden (Germany); Kulenkampff, J.; Gründig, M. [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Resource Ecology (IRE), Permoserstraße 15, 04318 Leipzig (Germany); Franke, K. [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Resource Ecology (IRE), Permoserstraße 15, 04318 Leipzig (Germany); Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiopharmacy (IRP), Permoserstraße 15, 04318 Leipzig (Germany); Lippmann-Pipke, J. [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Resource Ecology (IRE), Permoserstraße 15, 04318 Leipzig (Germany); Hampel, U. [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics (IFD), Bautzner Landstraße 400, 01328 Dresden (Germany); Helmholtz-Zentrum Dresden-Rossendorf, AREVA Endowed Chair of Imaging Techniques in Energy and Process Engineering, Technische Universität Dresden, 01062 Dresden (Germany)

    2014-02-15

    Highlights: • Particle deposition in a pebble bed was recorded by positron emission tomography. • The particles were radioactively labelled and their spatial distribution was recorded. • Particle deposition was mainly driven by particle inertia and turbulent dispersion. • Particle deposits form hot spots on the upstream face of the single pebbles. - Abstract: Accidental scenarios such as the depressurisation of the primary circuit of high temperature gas cooled pebble bed reactors may lead to the release of fission products via the discharge of radioactive graphite dust. For a detailed source term assessment in such accident scenarios knowledge of the flow mechanics of dust transport in complex coolant circuit components, like pebble beds, recuperator structures and pipe systems is necessary. In this article an experimental study of aerosol deposition in a pebble bed is described. We investigated the deposition of radiolabelled liquid aerosol particles in a scaled pebble bed in an air-driven small-scale aerosol flow test facility under isothermal ambient conditions. The aerosol particles were generated by means of a condensational aerosol generator with potassium-fluoride (KF) condensation nuclei. Particle concentration measurements upstream and downstream of the pebble bed were performed by isokinetic sampling and particle counting. The results agree with typical deposition curves for turbulent and inertia driven particle deposition. Furthermore, positron emission tomography (PET) was performed to visualize and measure particle deposition distributions in the pebble bed. Results of a selected deposition experiment with moderately large particles (d{sub aero} = 3.5 μm, Re{sup ′}{sub pb}=2200) show that the deposited particles are located in the vicinity of the upstream stagnation points of the pebbles. These findings support the thesis that inertia driven particle deposition is predominating.

  5. Attenuation correction in pulmonary and myocardial single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Almquist, H

    2000-01-01

    The objective was to develop and validate methods for single photon emission computed tomography, SPECT, allowing quantitative physiologic and diagnostic studies of lung and heart. A method for correction of variable attenuation in SPECT, based on transmission measurements before administration of an isotope to the subject, was developed and evaluated. A protocol based upon geometrically well defined phantoms was developed. In a mosaic pattern phantom count rates were corrected from 39-43% to 101-110% of reference. In healthy subjects non-gravitational pulmonary perfusion gradients observed without attenuation correctionwere artefacts caused by attenuation. Pulmonary density in centre of right lung, obtained from the transmission measurement, was 0.28 {+-} 0.03 g/ml in normal subjects. Mean density was lower in large lungs compared to smaller ones. We also showed that regional ventilation/perfusion ratios could be measured with SPECT, using the readily available tracer {sup 133}Xe. Because of the low energy of {sup 133}Xe this relies heavily upon attenuation correction. A commercially available system for attenuation correction with simultaneous emission and transmission, considered to improve myocardial SPECT, performed erroneously. This could lead to clinical misjudgement. We considered that manufacturer-independent pre-clinical tests are required. In a test of two other commercial systems, based on different principles, an adapted variant of our initial protocol was proven useful. Only one of the systems provided correct emission count rates independently on phantom configuration. Errors in the other system were related to inadequate compensation of the influence of emission activity on the transmission study.

  6. Sensitivity of 6-[F-18]fluoro-L-dihydroxyphenylalanine positron emission tomography for localizing tumors causing catecholamine excess

    NARCIS (Netherlands)

    Fiebrich, H.; Brouwers, A H; Kerstens, M. N.; Pijl, M. E.; Kema, I. P.; de Jong, J. R.; van der Wal, J. E.; Sluiter, W. J.; de Vries, E. G.; Links, T. P.

    11064 Background: Positron emission tomography (PET) using the catecholamine precursor 6-[F-18]fluoro-L-dihydroxyphenylalanine ((18)F-DOPA) has emerged as promising technique to localize tumors with catecholamine excess. This study investigated the sensitivity of (18)F-DOPA PET, compared to

  7. 2-¹⁸fluoro-deoxy-D-glucose positron emission tomography (FDG-PET) for postchemotherapy seminoma residual lesions

    DEFF Research Database (Denmark)

    Bachner, M; Loriot, Y; Gross-Goupil, M

    2012-01-01

    2-¹⁸fluoro-deoxy-D-glucose positron emission tomography (FDG-PET) has been recommended in international guidelines in the evaluation of postchemotherapy seminoma residuals. Our trial was designed to validate these recommendations in a larger group of patients....

  8. Few-view single photon emission computed tomography (SPECT) reconstruction based on a blurred piecewise constant object model

    DEFF Research Database (Denmark)

    Wolf, Paul A.; Jørgensen, Jakob Sauer; Schmidt, Taly G.

    2013-01-01

    A sparsity-exploiting algorithm intended for few-view Single Photon Emission Computed Tomography (SPECT) reconstruction is proposed and characterized. The algorithm models the object as piecewise constant subject to a blurring operation. To validate that the algorithm closely approximates the true...

  9. Tyrosine positron emission tomography and protein synthesis rate in pituitary adenoma : Different effects of surgery and radiation therapy

    NARCIS (Netherlands)

    van den Bergh, Alfons C. M.; Pruim, Jan; Links, Thera P.; Vliet , van der Anton M.; Sluiter, Wim; Wolffenbuttel, Bruce H. R.; Langendijk, Johannes A.; Hoving, Eelco W.; Dullaart, Robin P. F.

    Introduction: Positron emission tomography (PET) using amino acid tracers is able to establish biochemical tumour characterization in vivo. The use of PET in the follow-up of non-functioning pituitary adenomas (NFA) and growth hormone producing pituitary adenomas (GHA) after surgery and radiation

  10. Levodopa pharmacokinetic-pharmacodynamic modeling and 6-[F-18]levodopa positron emission tomography in patients with Parkinson's disease

    NARCIS (Netherlands)

    Dietz, M; Harder, S; Graff, J; Kunig, G; Vontobel, P; Leenders, KL; Baas, H

    Objective: Parameters of a pharmacokinetic-pharmacodynamic (PK-PD) model of levodopa have been claimed to reflect the magnitude of the dopaminergic deficit in patients with Parkinson's disease. The aim of this study was to correlate such parameters with positron emission tomography (PET) with

  11. Effects of high amphetamine dose on mood and cerebral glucose metabolism in normal volunteers using positron emission tomography (PET)

    NARCIS (Netherlands)

    Vollenweider, FX; Maguire, RP; Leenders, KL; Mathys, K; Angst, J

    1998-01-01

    The effects of high euphorigenic doses of D-amphetamine (0.9-1.0 mg/kg p.o.) on regional cerebral glucose metabolism (rCMRglu) and psychological measures were investigated in 10 healthy human volunteers using a within-subject design and [F-18]-fluorodeoxygrucose positron emission tomography

  12. MeV-range velocity-space tomography from gamma-ray and neutron emission spectrometry measurements at JET

    DEFF Research Database (Denmark)

    Salewski, Mirko; Nocente, M.; Jacobsen, Asger Schou

    2017-01-01

    We demonstrate the measurement of a 2D MeV-range ion velocity distribution function by velocity-space tomography at JET. Deuterium ions were accelerated into the MeV-range by third harmonic ion cyclotron resonance heating. We made measurements with three neutron emission spectrometers and a high-...

  13. Positron emission tomography studies of human airways using an inhaled beta-adrenoceptor antagonist, S-11C-CGP 12388

    NARCIS (Netherlands)

    Van Waarde, Aren; Maas, Bram; Doze, Petra; Slart, Riemer H.; Frijlink, Henderik W.; Vaalburg, Willem; Elsinga, Philippus

    2005-01-01

    Objectives: Positron emission tomography (PET) scanning may provide information on changes in the density and affinity of airway beta-adrenoceptors in lung diseases. However, the injection of a radiolabeled P-blocker results in a pulmonary PET signal that reflects the binding of the ligand in the

  14. Exploiting the Metal-Chelating Properties of the Drug Cargo for In Vivo Positron Emission Tomography Imaging of Liposomal Nanomedicines

    DEFF Research Database (Denmark)

    Edmonds, Scott; Volpe, Alessia; Shmeeda, Hilary

    2016-01-01

    The clinical value of current and future nanomedicines can be improved by introducing patient selection strategies based on noninvasive sensitive whole-body imaging techniques such as positron emission tomography (PET). Thus, a broad method to radiolabel and track preformed nanomedicines such as ...

  15. A fluorine-18 labeled progestin as an imaging agent for progestin receptor positive tumors with positron emission tomography

    NARCIS (Netherlands)

    Verhagen, Aalt; Elsinga, Philippus; DEGROOT, TJ; Paans, Anne; DEGOEIJ, CCJ; SLUYSER, M; Vaalburg, Willem

    The potential of the fluorine-18 labeled progestin 21-[F-18]fluoro-16-alpha-ethyl-19-norpregn-4-ene-3,20-dione ([F-18]FENP) as an imaging agent for the in vivo assessment of progestin receptor (PR) positive neoplasms with positron emission tomography has been investigated. Tissue distribution

  16. Measurement of clinical and subclinical tumour response using [F-18]-fluorodeoxyglucose and positron emission tomography : Review and 1999 EORTC recommendations

    NARCIS (Netherlands)

    Young, H; Baum, R; Cremerius, U; Herholz, K; Hoekstra, O; Lammertsma, AA; Pruim, J; Price, P

    1999-01-01

    [F-18]-fluorodeoxyglucose ([F-18]-FDG) uptake is enhanced in most malignant tumours which in turn can be measured using positron emission tomography (PET). A number of small clinical trials have indicated that quantification of the change in tumour [F-18]-FDG uptake may provide an early, sensitive,

  17. 18F-2-Fluoro-2-Deoxy-D-Glucose Positron Emission Tomography in Staging of Locally Advanced Breast Cancer

    NARCIS (Netherlands)

    Hoeven, J.J.M. van der; Krak, N.C.; Hoekstra, O.S.; Comans, E.F.I.; Boom, R.P.A.; Geldere, D. van; Meijer, S.; Wall, E. van der; Buter, J.; Pinedo, H.M.; Teule, G.J.J.; Lammertsma, A.A.

    2004-01-01

    PURPOSE To prospectively evaluate the effect of adding whole-body 18F-2-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) to conventional screening for distant metastases in patients with locally advanced breast cancer (LABC). PATIENTS AND METHODS All women with LABC referred for

  18. Thalamic glucose metabolism in temporal lobe epilepsy measured with 18F-FDG positron emission tomography (PET)

    NARCIS (Netherlands)

    Khan, N; Leenders, KL; Hajek, M; Maguire, P; Missimer, J; Wieser, HG

    1997-01-01

    Thalamic glucose metabolism has been studied in 24 patients suffering from temporal lobe epilepsy (TLE) using interictal F-18-fluorodeoxyglucose (FDG) positron emission tomography (PET). A total of 17 patients had a unilateral TL seizure onset, 11 of these patients had a mesial temporal lobe

  19. Regional myocardial oxygen consumption estimated by carbon-11 acetate and positron emission tomography before and after repetitive ischemia

    DEFF Research Database (Denmark)

    Kofoed, K F; Hansen, P R; Holm, S

    2011-01-01

    Preserved myocardial oxygen consumption estimated by carbon 11-acetate and positron emission tomography (PET) in myocardial regions with chronic but reversibly depressed contractile function in patients with ischemic heart disease have been suggested to be caused by repeated short episodes of acute...

  20. (89)Zr-Immuno-Positron Emission Tomography in Oncology: State-of-the-Art (89)Zr Radiochemistry

    NARCIS (Netherlands)

    Heskamp, S.; Raavé , R.; Boerman, O.C.; Rijpkema, M.J.P.; Goncalves, V.; Denat, F.

    2017-01-01

    Immuno-positron emission tomography (immunoPET) with (89)Zr-labeled antibodies has shown great potential in cancer imaging. It can provide important information about the pharmacokinetics and tumor-targeting properties of monoclonal antibodies and may help in anticipating on toxicity. Furthermore,

  1. 89Zr-Immuno-Positron Emission Tomography in Oncology: State-of-the-Art 89Zr Radiochemistry

    NARCIS (Netherlands)

    Heskamp, S.; Raave, R.; Boerman, O.C.; Rijpkema, M.J.P.; Goncalves, V.; Denat, F.

    2017-01-01

    Immuno-positron emission tomography (immunoPET) with 89Zr-labeled antibodies has shown great potential in cancer imaging. It can provide important information about the pharmacokinetics and tumor-targeting properties of monoclonal antibodies and may help in anticipating on toxicity. Furthermore, it

  2. Comparison of planar bone scintigraphy and single photon emission computed tomography in patients suspected of having unilateral condylar hyperactivity

    NARCIS (Netherlands)

    Saridin, C.P.; Raijmakers, P.G.H.M.; Tuinzing, D.B.; Becking, A.G.

    2008-01-01

    Objective A comparison is made of single photon emission computed tomography (SPECT) and planar bone scintigraphy in the diagnosis of patients with suspected unilateral condylar hyperactivity (UCH). Study design The subjects comprised 56 patients with suspected UCH who underwent SPECT and regular

  3. Comparison of planar bone scintigraphy and single photon emission computed tomography in patients suspected of having unilateral condylar hyperactivity

    NARCIS (Netherlands)

    Saridin, Carrol P.; Raijmakers, Pieter G. H. M.; Tuinzing, Dirk B.; Becking, Alfred G.

    2008-01-01

    A comparison is made of single photon emission computed tomography (SPECT) and planar bone scintigraphy in the diagnosis of patients with suspected unilateral condylar hyperactivity (UCH). The subjects comprised 56 patients with suspected UCH who underwent SPECT and regular planar bone scans.

  4. Lhermitte-Duclos disease presenting with positron emission tomography-magnetic resonance fusion imaging: a case report

    Directory of Open Access Journals (Sweden)

    Calabria Ferdinando

    2012-03-01

    Full Text Available Abstract Introduction Lhermitte-Duclos disease or dysplastic gangliocytoma of the cerebellum is an extremely rare tumor. It is a slowly enlarging mass within the cerebellar cortex. The majority of cases are diagnosed in the third or fourth decade of life. Case presentation We report the case of a 37-year-old Caucasian woman who underwent positron emission tomography-computed tomography with fluorine-18-fluorodeoxyglucose for evaluation of a solitary lung node. No pathological uptake was detected in the solitary lung node but the positron emission tomography-computed tomography of her brain showed intense tracer uptake, suggestive of a malignant neoplasm, in a mass in her left cerebellar lobe. Our patient had experienced two years of occipital headache and movement disorder. Subsequently, magnetic resonance imaging was performed with contrast agent administration, showing a large subtentorial mass in her left cerebellar hemisphere, with compression and dislocation of the fourth ventricle. Metabolic data provided by positron emission tomography and morphological magnetic resonance imaging views were fused in post-processing, allowing a diagnosis of dysplastic gangliocytoma with increased glucose metabolism. Total resection of the tumor was performed and histological examination confirmed the diagnosis of Lhermitte-Duclos disease. Conclusions Our case indicates that increased uptake of fluorine-18-fluorodeoxyglucose may be misinterpreted as a neoplastic process in the evaluation of patients with Lhermitte-Duclos disease, but supports the usefulness of integrated positron emission tomography-magnetic resonance imaging in the exact pathophysiologic explanation of this disease and in making the correct diagnosis. However, an accurate physical examination and exact knowledge of clinical data is of the utmost importance.

  5. Magnetic resonance-based motion correction for positron emission tomography imaging.

    Science.gov (United States)

    Ouyang, Jinsong; Li, Quanzheng; El Fakhri, Georges

    2013-01-01

    Positron emission tomography (PET) image quality is limited by patient motion. Emission data are blurred owing to cardiac and/or respiratory motion. Although spatial resolution is 4 mm for standard clinical whole-body PET scanners, the effective resolution can be as low as 1 cm owing to motion. Additionally, the deformation of attenuation medium causes image artifacts. Previously, gating has been used to "freeze" the motion, but led to significantly increased noise level. Simultaneous PET/magnetic resonance (MR) modality offers a new way to perform PET motion correction. MR can be used to measure 3-dimensional motion fields, which can then be incorporated into the iterative PET reconstruction to obtain motion-corrected PET images. In this report, we present MR imaging techniques to acquire dynamic images, a nonrigid image registration algorithm to extract motion fields from acquired MR images, and a PET reconstruction algorithm with motion correction. We also present results from both phantom and in vivo animal PET/MR studies. We demonstrate that MR-based PET motion correction using simultaneous PET/MR improves image quality and lesion detectability compared with gating and no motion correction. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Value of 18fluorodeoxyglucose-positron-emission tomography in amyotrophic lateral sclerosis: a prospective study.

    Science.gov (United States)

    Van Laere, Koen; Vanhee, Annelies; Verschueren, Jolien; De Coster, Liesbeth; Driesen, An; Dupont, Patrick; Robberecht, Wim; Van Damme, Philip

    2014-05-01

    Amyotrophic lateral sclerosis (ALS) is a neurodegenerative disorder primarily affecting the motor system, with extramotor involvement to a variable extent. Biomarkers for early differential diagnosis and prognosis are needed. An autosomal dominant hexanucleotide (GGGGCC) expansion in the noncoding region of the chromosome 9 open reading frame 72 (C9orf72) gene is the most frequent genetic cause of ALS, but its metabolic pattern has not been studied systematically. To evaluate the use of 18fluorodeoxyglucose-positron-emission tomography as a marker of ALS pathology and investigate whether a specific metabolic signature is present in patients with C9orf72 mutations. In total, 81 patients with a suspected diagnosis of ALS at University Hospital Leuven were prospectively investigated. All underwent detailed neurological examination and electrodiagnostic and genetic testing for the major known genetic causes of ALS (C9orf72, SOD1, TARDBP, and FUS). A diagnosis of ALS was made in 70 of 81 patients. Of these, 11 were C9orf72 positive and 59 were C9orf72 negative. In 7 patients, the diagnosis of primary lateral sclerosis was made; 4 patients had progressive muscular atrophy. A screened healthy control population was used for comparison. Positron-emission tomographic data were spatially normalized and analyzed using a predefined volume of interest and a voxel-based analysis (SPM8). Discriminant analysis was done both volume of interest based and voxel based using a support vector machine approach. Compared with control participants, 18fluorodeoxyglucose-positron-emission tomography showed perirolandic and variable prefrontal hypometabolism in most patients. Patients with primary lateral sclerosis showed a similar pattern. Patients with C9orf72-positive ALS had discrete relative hypometabolism in the thalamus and posterior cingulate compared with those with C9orf72-negative ALS. A posteriori-corrected discriminant analysis was able to correctly classify 95% of ALS cases and

  7. 18 F-sodium fluoride positron emission tomography of the equine distal limb: Exploratory study in three horses.

    Science.gov (United States)

    Spriet, M; Espinosa, P; Kyme, A Z; Phillips, K L; Katzman, S A; Galuppo, L D; Stepanov, P; Beylin, D

    2018-01-01

    Positron emission tomography (PET) is a cross-sectional, functional imaging modality that has recently become available to the horse. The use of 18 F-sodium fluoride (18 F-NaF), a PET bone tracer, has not previously been reported in this species. To assess the feasibility of 18 F-NaF PET in the equine distal limb and explore possible applications in the horse in comparison with other imaging modalities. Exploratory descriptive study involving three research horses. Horses were placed under general anaesthesia prior to intravenous (i.v.) administration of 1.5 MBq/kg of 18 F-NaF. Positron emission tomography imaging of both front feet and fetlocks was performed using a portable scanner. Computed tomography (CT) of the distal limb was performed under a separate anaesthetic episode. Bone scintigraphy and magnetic resonance imaging (MRI) were subsequently performed under standing sedation. Images obtained from PET and other imaging modalities were independently assessed and the results correlated. Positron emission tomography images were obtained without complication. The radiation exposure rate was similar to equine bone scintigraphy. Positron emission tomography detected focal 18 F-NaF uptake in areas where other imaging modalities did not identify any abnormalities. This included sites of ligamentous attachment, subchondral compact bone plate and the flexor cortex of the navicular bone. 18 F-NaF uptake was identified in some, but not all, osseous fragments and areas of osseous formation, suggesting a distinction between active and inactive lesions. A small number of horses were included and histopathology was not available. 18 F-NaF PET imaging of the equine distal limb provides useful additional information when compared with CT, MRI and scintigraphy and has the potential for both research and clinical applications in the horse. The Summary is available in Chinese - see Supporting information. © 2017 EVJ Ltd.

  8. Digital contrast enhancement of (18)Fluorine-fluorodeoxyglucose positron emission tomography images in hepatocellular carcinoma.

    Science.gov (United States)

    Pandey, Anil Kumar; Sharma, Sanjay Kumar; Agarwal, Krishan Kant; Sharma, Punit; Bal, Chandrasekhar; Kumar, Rakesh

    2016-01-01

    The role of (18)fluorodeoxyglucose positron emission tomography (PET) is limited for detection of primary hepatocellular carcinoma (HCC) due to low contrast to the tumor, and normal hepatocytes (background). The aim of the present study was to improve the contrast between the tumor and background by standardizing the input parameters of a digital contrast enhancement technique. A transverse slice of PET image was adjusted for the best possible contrast, and saved in JPEG 2000 format. We processed this image with a contrast enhancement technique using 847 possible combinations of input parameters (threshold "m" and slope "e"). The input parameters which resulted in an image having a high value of 2(nd) order entropy, and edge content, and low value of absolute mean brightness error, and saturation evaluation metrics, were considered as standardized input parameters. The same process was repeated for total nine PET-computed tomography studies, thus analyzing 7623 images. The selected digital contrast enhancement technique increased the contrast between the HCC tumor and background. In seven out of nine images, the standardized input parameters "m" had values between 150 and 160, and for other two images values were 138 and 175, respectively. The value of slope "e" was 4 in 4 images, 3 in 3 images and 1 in 2 images. It was found that it is important to optimize the input parameters for the best possible contrast for each image; a particular value was not sufficient for all the HCC images. The use of above digital contrast enhancement technique improves the tumor to background ratio in PET images of HCC and appears to be useful. Further clinical validation of this finding is warranted.

  9. Brain glucose utilization in systemic lupus erythematosus with neuropsychiatric symptoms: a controlled positron emission tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Otte, A. [Institute of Nuclear Medicine, University Hospital, Basel (Switzerland)]|[Department of Nuclear Medicine, University Hospital Freiburg (Germany); Weiner, S.M. [Department of Rheumatology and Immunology, University Hospital Freiburg (Germany); Peter, H.H. [Department of Rheumatology and Immunology, University Hospital Freiburg (Germany); Mueller-Brand, J. [Institute of Nuclear Medicine, University Hospital, Basel (Switzerland); Goetze, M. [Institute of Nuclear Medicine, University Hospital, Basel (Switzerland); Moser, E. [Department of Nuclear Medicine, University Hospital Freiburg (Germany); Gutfleisch, J. [Department of Rheumatology and Immunology, University Hospital Freiburg (Germany); Hoegerle, S. [Department of Nuclear Medicine, University Hospital Freiburg (Germany); Juengling, F.D. [Department of Nuclear Medicine, University Hospital Freiburg (Germany); Nitzsche, E.U. [Department of Nuclear Medicine, University Hospital Freiburg (Germany)

    1997-07-01

    In contrast to morphological imaging [such as magnetic resonance imaging (MRI) or computed tomography], functional imaging may be of advantage in the detection of brain abnormalities in cases of neuropsychiatric systemic lupus erythematosus (SLE). Therefore, we studied 13 patients (aged 40{+-}14 years, 11 female, 2 male) with neuropsychiatric SLE who met four of the American Rheumatism Association criteria for the classification of SLE. Ten clinically and neurologically healthy volunteers served as controls (aged 40{+-}12 years, 5 female, 5 male). Both groups were investigated using fluorine-18-labelled fluorodeoxyglucose brain positron emission tomography (PET) and cranial MRI. The normal controls and 11 of the 13 patients showed normal MRI scans. However, PET scan was abnormal in all 13 SLE patients. Significant group-to-group differences in the glucose metabolic index (GMI=region of interest uptake/global uptake at the level of the basal ganglia and thalamus) were found in the parieto-occipital region on both sides: the GMI of the parieto-occipital region on the right side was 0.922{+-}0.045 in patients and 1.066{+-}0.081 in controls (P<0.0001, Mann Whitney U test), while on the left side it was 0.892{+-}0.060 in patients and 1.034{+-}0.051 in controls (P=0.0002). Parieto-occipital hypometabolism is a conspicuous finding in mainly MRI-negative neuropsychiatric SLE. As the parieto-occipital region is located at the boundary of blood supply of all three major arteries, it could be the most vulnerable zone of the cerebrum and may be affected at an early stage of the cerebrovascular disease. (orig.). With 1 fig., 1 tab.

  10. In vivo imaging of schistosomes to assess disease burden using positron emission tomography (PET).

    Science.gov (United States)

    Salem, Nicolas; Balkman, Jason D; Wang, Jing; Wilson, David L; Lee, Zhenghong; King, Christopher L; Basilion, James P

    2010-09-21

    Schistosomes are chronic intravascular helminth parasites of humans causing a heavy burden of disease worldwide. Diagnosis of schistosomiasis currently requires the detection of schistosome eggs in the feces and urine of infected individuals. This method unreliably measures disease burden due to poor sensitivity and wide variances in egg shedding. In vivo imaging of schistosome parasites could potentially better assess disease burden, improve management of schistosomiasis, facilitate vaccine development, and enhance study of the parasite's biology. Schistosoma mansoni (S. mansoni) have a high metabolic demand for glucose. In this work we investigated whether the parasite burden in mice could be assessed by positron emission tomography (PET) imaging with 2-deoxy-2[(18)F]fluoro-D-glucose (FDG). Live adult S. mansoni worms FDG uptake in vitro increased with the number of worms. Athymic nude mice infected with S. mansoni 5-6 weeks earlier were used in the imaging studies. Fluorescence molecular tomography (FMT) imaging with Prosense 680 was first performed. Accumulation of the imaging probe in the lower abdomen correlated with the number of worms in mice with low infection burden. The total FDG uptake in the common portal vein and/or regions of elevated FDG uptake in the liver linearly correlated to the number of worms recovered from infected animals (R(2) =0.58, Pworm burden in mice with more than 50 worms (R(2) = 0.85, Pworms in a mouse with a high infection burden were in the portal vein, but not in a mouse with a low infection burden. FDG uptake in recovered worms measured by well counting closely correlated with worm number (R(2) = 0.85, Pworm burden in schistosomiasis-infected animals. Future investigations aiming at minimizing non-specific FDG uptake and to improve the recovery of signal from worms located in the lower abdomen will include the development of more specific radiotracers.

  11. {sup 18}F-fluorodeoxyglucose uptake on positron emission tomography in mucinous adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Shuji, E-mail: murakamis@kcch.jp [Department of Thoracic Oncology, Kanagawa Cancer Center Hospital (Japan); Saito, Haruhiro; Karino, Fumi; Kondo, Tetsuro; Oshita, Fumihiro; Ito, Hiroyuki; Nakayama, Haruhiko [Department of Thoracic Oncology, Kanagawa Cancer Center Hospital (Japan); Yokose, Tomoyuki [Department of Pathology, Kanagawa Cancer Center Hospital (Japan); Yamada, Kouzo [Department of Thoracic Oncology, Kanagawa Cancer Center Hospital (Japan)

    2013-11-01

    Background: The prognostic value of maximum standardized uptake value (maxSUV) on {sup 18}F-fluorodeoxyglucose positron emission tomography (FDG-PET) is known for localized pulmonary adenocarcinoma, which is most commonly non-mucinous adenocarcinoma. We examined the validity of thin-section computed tomography (TS-CT) and FDG-PET findings in mucinous adenocarcinoma. Materials and Methods: TS-CT and FDG-PET were performed on 25 patients with mucinous lung adenocarcinoma that was subsequently resected between January 2009 and March 2013. Based on the percentage reduction of maximum tumor diameter on the mediastinal window image compared with the diameter on the lung window image on TS-CT, tumors were classified as air-type (≥50%) or solid-type (<50%). All resected specimens were pathologically diagnosed according to the International Association for the Study of Lung Cancer (IASLC) classification, and the diameter of the pathological invasive area was assessed. Results: Most mucinous adenocarcinomas were located in the lower lobe. All except two were classified as solid-type tumor on TS-CT. Multiple regression analysis revealed the correlation of maxSUV with pathological tumor size and diameter of pathological invasive area; these two parameters showed no significant correlation with each other (r = 0.354, p = 0.083). maxSUV was significantly lower for tumors with invasive area ≤5 mm than for tumors with invasive area >5 mm (1.62 vs. 3.77, p = 0.01), but no statistically significant difference was found in terms of other pathological invasive findings such as the presence of lymphatic or vascular invasion, pleural involvement, or predominant histological subtype. Conclusions: Most mucinous adenocarcinomas had appearances of solid-type tumor on TS-CT. maxSUV on FDG-PET indicates the pathological invasive area in mucinous adenocarcinoma as well as non-mucinous adenocarcinoma.

  12. Safety of ventilation/perfusion single photon emission computed tomography for pulmonary embolism diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Le Roux, Pierre-Yves; Palard, Xavier; Robin, Philippe; Abgral, Ronan; Querellou, Solene; Salaun, Pierre-Yves [Universite Europeenne de Bretagne, Brest (France); Universite de Brest, Brest (France); CHRU de la Cavale Blanche, Service de medecine nucleaire, Brest (France); Delluc, Aurelien; Couturaud, Francis [Universite Europeenne de Bretagne, Brest (France); Universite de Brest, Brest (France); CHRU de la Cavale Blanche, Departement de medecine interne et de pneumologie, Brest (France); Le Gal, Gregoire [Universite Europeenne de Bretagne, Brest (France); University of Ottawa, Ottawa Hospital Research Institute, Ottawa (Canada); CHRU de la Cavale Blanche, Departement de medecine interne et de pneumologie, Brest (France); Universite de Brest, Brest (France)

    2014-10-15

    The aim of this management outcome study was to assess the safety of ventilation/perfusion single photon emission computed tomography (V/Q SPECT) for the diagnosis of pulmonary embolism (PE) using for interpretation the criteria proposed in the European Association of Nuclear Medicine (EANM) guidelines for V/Q scintigraphy. A total of 393 patients with clinically suspected PE referred to the Nuclear Medicine Department of Brest University Hospital from April 2011 to March 2013, with either a high clinical probability or a low or intermediate clinical probability but positive D-dimer, were retrospectively analysed. V/Q SPECT were interpreted by the attending nuclear medicine physician using a diagnostic cut-off of one segmental or two subsegmental mismatches. The final diagnostic conclusion was established by the physician responsible for patient care, based on clinical symptoms, laboratory test, V/Q SPECT and other imaging procedures performed. Patients in whom PE was deemed absent were not treated with anticoagulants and were followed up for 3 months. Of the 393 patients, the prevalence of PE was 28 %. V/Q SPECT was positive for PE in 110 patients (28 %) and negative in 283 patients (72 %). Of the 110 patients with a positive V/Q SPECT, 78 (71 %) had at least one additional imaging test (computed tomography pulmonary angiography or ultrasound) and the diagnosis of PE was eventually excluded in one patient. Of the 283 patients with a negative V/Q SPECT, 74 (26 %) patients had another test. The diagnosis of PE was finally retained in one patient and excluded in 282 patients. The 3-month thromboembolic risk in the patients not treated with anticoagulants was 1/262: 0.38 % (95 % confidence interval 0.07-2.13). A diagnostic management including V/Q SPECT interpreted with a diagnostic cut-off of ''one segmental or two subsegmental mismatches'' appears safe to exclude PE. (orig.)

  13. [Positron emission tomography for preoperative lymph node diagnosis in esophageal carcinoma].

    Science.gov (United States)

    Kneist, W; Schreckenberger, M; Bartenstein, P; Grünwald, F; Oberholzer, K; Junginger, Th

    2003-10-01

    Exact preoperative staging is a prerequisite for the indication and the choice of appropriate operative technique for patients with esophageal carcinoma. The objective of this prospective study was to assess whether positron emission tomography (PET) with 18F-fluorodeoxyglucose (FDG) increases the accuracy of preoperative lymph node staging with standard computed tomography (CT) and thus leads to a different surgical approach. Fifty-eight patients with carcinoma of the esophagus (46 men and 12 women) with a median age of 61 years underwent FDG-PET imaging of the neck, chest, and abdomen as well as CT of the chest and abdomen. Sensitivity, specificity, and accuracy were calculated for both imaging techniques to evaluate the detection of histologically verified lymph node metastases. The FDG-PET showed higher specificity, whereas CT proved to be more accurate for detecting lymph node metastases not only of the abdomen (73% vs 59%) but also of the thorax (73% vs 63%). Resections were transhiatal in 23 patients and transthoracal in 16. As a supplement to conventional CT diagnostic procedure, FDG-PET was not decisive for the surgical approach. Altogether, pretherapeutical PET imaging did not increase the accuracy of lymph node staging for our patients with esophageal carcinoma, which had already been defined through CT. Therefore, no new consequences resulted for the surgical procedure. Due to the high costs involved with PET investigation, lymph node staging with it is momentarily indicated mainly for clinical studies and when CT does not offer unequivocal results. Increased sensitivity of the already advantageous whole-body FDG-PET imaging by means of tumor-affinitive radiopharmaceuticals and optimized apparatus resolution could lead to new indications for this staging procedure.

  14. Positron emission tomography for staging esophageal cancer: does it lead to a different therapeutic approach?

    Science.gov (United States)

    Kneist, Werner; Schreckenberger, Mathias; Bartenstein, Peter; Grünwald, Frank; Oberholzer, Katja; Junginger, Theodor

    2003-10-01

    Accurate preoperative staging is essential for the indication and selection of the appropriate surgical procedure in patients with esophageal cancer. The present prospective study was designed to determine if the preoperative use of (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET) increases the accuracy of staging esophageal cancer compared with computed tomography (CT) and if it thereby leads to a different therapeutic approach. A total of 58 patients, 46 men and 12 women (mean age 61 years), with histologic proof of esophageal carcinoma underwent FDG-PET of the neck, chest, and abdomen, as well as CT of the chest and abdomen, to determine tumor stage. FDG-PET and CT data were compared with each other and with pathohistologic findings. Sensitivity, specificity, and overall accuracy for detecting histologically verified lymph node and distant metastases were calculated for FDG-PET and CT. FDG-PET showed a higher specificity, whereas CT had higher accuracy for detecting both abdominal (73% vs. 59%) and thoracic (73% vs. 63%) lymph node metastases. The accuracy of detecting blood-borne and lymphatic distant metastases was identical for CT and FDG-PET imaging (50%). FDG-PET had a higher specificity than CT (87% vs. 13%) but lower sensitivity (35% vs. 67%). FDG-PET did not provide new information on the indication for surgery, nor was it helpful for choosing the appropriate surgical procedure in patients with esophageal carcinoma. In view of the relatively high cost of FDG-PET examinations, the use of this modality is indicated primarily in patients with inconclusive CT findings or for scientific research projects. Higher sensitivity as a result of tumor-affinity radiopharmaceuticals and optimized apparatus resolution, in addition to the advantages offered by whole-body PET scanning, may lead to new indications for this staging procedure in the future.

  15. Utility of positron emission tomography for tumour surveillance in children with neurofibromatosis type 1

    Energy Technology Data Exchange (ETDEWEB)

    Moharir, Mahendranath [Hospital for Sick Children, Division of Neurology, Ontario (Canada); London, Kevin [Children' s Hospital at Westmead, Department of Nuclear Medicine, Sydney (Australia); Howman-Giles, Robert [University of Sydney, Discipline of Imaging, Faculty of Medicine, Sydney (Australia); North, Kathryn [Children' s Hospital at Westmead, Institute for Neuroscience and Muscle Research, Sydney, NSW (Australia)

    2010-07-15

    There is little consensus regarding optimal surveillance of optic pathway glioma (OPG) and plexiform neurofibroma (PNF) in childhood neurofibromatosis type 1 (NF1). {sup 18}F-2-Fluoro-2-deoxy-D-glucose (FDG) positron emission tomography and computed tomography (PET/CT) is employed in the surveillance of adult PNFs; but its utility has neither been specifically studied in children with PNFs nor in children with OPG. Review of PET/CT studies was performed in NF1 children with OPG or PNF. FDG-avidity of tumours was semi-quantitatively analysed and graded by calculating the maximum standardised uptake value (SUV{sub max}) [grade 1: <3 (low), grade 2: >3-<4 (intermediate), grade 3: >4 (intense)]. Eighteen children (ten girls; median age: 8.5-years) had PET/CT. Nineteen OPGs were imaged. The SUV{sub max} could be measured in 16. Ten were grade 1 and three each were grade 2 and grade 3. FDG-avidity reduced from grade 3 to grade 1 in two symptomatic OPGs following chemotherapy and this was associated with clinical improvement. PET/CT diagnosed symptomatic OPGs with a sensitivity of 0.625 [95% confidence interval (CI): 0.259-0.897] and specificity of 0.875 (95% CI: 0.466-0.993). Sixteen PNFs were imaged. Twelve were grade 1 and two each were grade 2 and grade 3. The two grade 3 PNFs were confirmed malignant peripheral nerve sheath tumours. PET/CT diagnosed malignant transformation with a sensitivity of 1.0 (95% CI: 0.197-1.0) and specificity of 0.857 (95% CI: 0.561-0.974). PET/CT may contribute useful information to the surveillance of OPG in childhood NF1 - particularly to identify progressive, symptomatic tumours. As in adults, PET/CT is useful for the detection of malignant transformation in PNFs in children with NF1. (orig.)

  16. The clinical utility of fluorodeoxyglucose-positron emission tomography for investigation of fever in immunocompromised children.

    Science.gov (United States)

    Wang, Shiqi Stacie; Mechinaud, Francoise; Thursky, Karin; Cain, Timothy; Lau, Eddie; Haeusler, Gabrielle M

    2017-12-13

    Fever in immunocompromised children presents significant challenges. We aimed to determine the clinical impact of fluorodeoxyglucose-positron emission tomography (FDG-PET) in combination with computed tomography (CT) in children with malignancy or following haematopoietic stem cell transplantation with prolonged or recurrent fever. Immunocompromised children who underwent FDG-PET/CT for investigation of prolonged or recurrent fever were identified from hospital databases. The clinical impact of the FDG-PET/CT was considered 'high' if it contributed to any of the following: diagnosis of a new site infection/inflammation, change to antimicrobials or chemotherapy, or additional investigations or specialist consult contributing to final diagnosis. Fourteen patients underwent an FDG-PET/CT for prolonged or recurrent fever. Median age was 11 years and 46% had diagnosis of acute lymphoblastic leukaemia. The median absolute neutrophil count on the day of FDG-PET/CT was 0.47 cells/μL. The clinical impact of FDG-PET/CT was 'high' in 11 (79%) patients, contributing to rationalisation of antimicrobials in three, and cessation of antimicrobials in five. Compared to conventional imaging, FDG PET/CT identified seven additional sites of clinically significant infection/inflammation in seven patients. Of the 10 patients who had a cause of fever identified, FDG-PET/CT contributed to the final diagnosis in six (60%). This study has identified potential utility for FDG-PET/CT in immunocompromised children with prolonged or recurrent fever. Further prospective studies are needed to compare FDG-PET/CT versus conventional imaging, to identify the optimal timing of FDG-PET/CT and to study the role of subsequent scans to monitor response to therapy. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  17. Design of a portable optical emission tomography system for microwave induced compact plasma for visible to near-infrared emission lines

    Energy Technology Data Exchange (ETDEWEB)

    Rathore, Kavita, E-mail: kavira@iitk.ac.in, E-mail: pmunshi@iitk.ac.in, E-mail: sudeepb@iitk.ac.in; Munshi, Prabhat, E-mail: kavira@iitk.ac.in, E-mail: pmunshi@iitk.ac.in, E-mail: sudeepb@iitk.ac.in [Nuclear Engineering and Technology Programme, Indian Institute of Technology Kanpur, Kanpur (India); Bhattacharjee, Sudeep, E-mail: kavira@iitk.ac.in, E-mail: pmunshi@iitk.ac.in, E-mail: sudeepb@iitk.ac.in [Department of Physics, Indian Institute of Technology Kanpur, Kanpur 208016 (India)

    2016-03-15

    A new non-invasive diagnostic system is developed for Microwave Induced Plasma (MIP) to reconstruct tomographic images of a 2D emission profile. A compact MIP system has wide application in industry as well as research application such as thrusters for space propulsion, high current ion beams, and creation of negative ions for heating of fusion plasma. Emission profile depends on two crucial parameters, namely, the electron temperature and density (over the entire spatial extent) of the plasma system. Emission tomography provides basic understanding of plasmas and it is very useful to monitor internal structure of plasma phenomena without disturbing its actual processes. This paper presents development of a compact, modular, and versatile Optical Emission Tomography (OET) tool for a cylindrical, magnetically confined MIP system. It has eight slit-hole cameras and each consisting of a complementary metal–oxide–semiconductor linear image sensor for light detection. The optical noise is reduced by using aspheric lens and interference band-pass filters in each camera. The entire cylindrical plasma can be scanned with automated sliding ring mechanism arranged in fan-beam data collection geometry. The design of the camera includes a unique possibility to incorporate different filters to get the particular wavelength light from the plasma. This OET system includes selected band-pass filters for particular argon emission 750 nm, 772 nm, and 811 nm lines and hydrogen emission H{sub α} (656 nm) and H{sub β} (486 nm) lines. Convolution back projection algorithm is used to obtain the tomographic images of plasma emission line. The paper mainly focuses on (a) design of OET system in detail and (b) study of emission profile for 750 nm argon emission lines to validate the system design.

  18. Preoperative lymph-node staging of invasive urothelial bladder cancer with 18F-fluorodeoxyglucose positron emission tomography/computed axial tomography and magnetic resonance imaging

    DEFF Research Database (Denmark)

    Jensen, Thor Knak; Holt, Per; Gerke, Oke

    2011-01-01

    OBJECTIVE: The treatment and prognosis of bladder cancer are based on the depth of primary tumour invasion and the presence of metastases. A highly accurate preoperative tumour, node, metastasis (TNM) staging is critical to proper patient management and treatment. This study retrospectively...... investigated the value of ¹⁸F-fluorodeoxyglucose (FDG) positron emission tomography/computed axial tomography (¹⁸F-FDG PET/CT) and magnetic resonance imaging (MRI) for preoperative N staging of bladder cancer. Material and methods. From June 2006 to January 2008, 48 consecutive patients diagnosed with bladder......) for MRI and ¹⁸F-FDG PET/CT, respectively. The differences in specificity and negative predictive values were not statistically significant. Conclusions. No significant statistical difference between ¹⁸F-FDG PET/CT and MRI for preoperative N staging of urothelial bladder cancer was found in the study...

  19. Infective endocarditis detected by 18F-fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography in a patient with occult infection

    Directory of Open Access Journals (Sweden)

    Chia-Lu Yeh

    2011-11-01

    Full Text Available Integrated 18F-fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography (FDG PET/CT has been clinically used to detect infectious lesions. We present a case with pyrexia and bacteremia of unknown origin. Whole body FDG PET/CT was arranged to look for an occult source of infection and it revealed a focal lesion with increased FDG uptake in the mitral valve area. Under suspicion of infective endocarditis, transthoracic echocardiography was repeated and then the presence of linear vegetation over the calcified mitral annulus was confirmed. Ultimately, definite infective endocarditis was diagnosed according to the Duke criteria. The patient recovered after the antibiotic therapy. In our case, FDG PET/CT can help to localize the exact site of occult infection, thereby guiding additional testing and facilitating timely definitive diagnosis and therapy.

  20. Use of NaF-18-Positron Emission Tomography/Computed Tomography in the Detection of Bone Metastasis from Papillary Renal Cell Carcinoma.

    Science.gov (United States)

    Aparici, Carina Mari; Win, Aung Zaw

    2014-05-01

    We present a case of a 60-year-old white male with a history of papillary renal cell carcinoma (PRCC) status postpartial nepherectomy. He was followed-up annually with abdominal computed tomography (CT) scans to monitor for tumor recurrence. A solitary metastatic bony lesion was detected by CT 4 years after partial nephrectomy and it was confirmed by NaF-positron emission tomography (PET)/CT and magnetic resonance imaging. He underwent external beam radiation therapy (XRT) for solitary metastasis to L1 vertebra. The L1 lesion was treated with XRT, which exhibited no fluorodeoxyglucose activity after the treatment. This is the first case report to mention the use of NaF-18-PET/CT in the detection of bone metastasis from PRCC. Our case once again emphasizes the usefulness of NaF-18-PET/CT in RCC follow-up.

  1. {sup 68}Gallium-arginine-glycine-aspartic acid and {sup 18}F-fluorodeoxyglucose position emission tomography/computed tomography in chondroblastic osteosarcoma of the skull

    Energy Technology Data Exchange (ETDEWEB)

    Orunmuyi, Akintunde; Modiselle, Moshe; Lengana, Thabo; Ebenhan, Thomas; Vorster, Mariza; Sathekge, Mike [Dept. of Nuclear MedicineUniversity of Pretoria and Steve Biko Academic Hospital, Pretoria (South Africa)

    2017-09-15

    We report the case of a 32 year-old male with Chondroblastic Osteosarcoma of the skull, which was imaged with both {sup 18}[F]fluorodeoxyglucose ({sup 18}F-FDG) positron emission tomography/computed tomography (PET/CT) and {sup 68}Gallium-arginine-glycine-aspartic acid ({sup 68}Ga-RGD) PET/CT. The {sup 18}F-FDG PET/CT did not demonstrate the tumour, whereas the {sup 68}Ga-RGD PET/CT clearly depicted a left-sided frontal tumour. {sup 68}Ga-RGD PET/CT may be a clinically useful imaging modality for early detection of recurrent osteosarcoma, considering the limitations of {sup 18}F-FDG PET in a setting of low glycolytic activity.

  2. Isolated thymic Langerhans cell histiocytosis discovered on F-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT)

    Energy Technology Data Exchange (ETDEWEB)

    Turpin, Sophie [CHU Sainte-Justine, Nuclear Medicine, Montreal (Canada); Carret, Anne-Sophie [CHU Sainte-Justine, Hemato-Oncology, Montreal (Canada); Dubois, Josee [CHU Sainte-Justine, Radiology, Montreal (Canada); Buteau, Chantal [CHU Sainte-Justine, Infectious Diseases, Montreal (Canada); Patey, Natalie [CHU Sainte-Justine, Pathology, Montreal (Canada)

    2015-11-15

    The thymic infiltration in young patients with multisystemic Langerhans cell histiocytosis and its radiologic features are well known. However, isolated thymic disease has seldom been reported in the literature. We report the case of a 10-month-old child admitted for fever of unknown origin. Whole-body F-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) was performed to identify a focus of infection. It demonstrated an unusual aspect of the thymus, which led to further investigation and revealed isolated infiltration of the thymus by Langerhans cell histiocytosis. The patient was treated accordingly and is now disease free. As evaluation of Langerhans cell histiocytosis patients with F-18 FDG PET/CT is becoming more frequent, it is important to be aware of the scintigraphical characteristics of thymic Langerhans cell histiocytosis. (orig.)

  3. Hybrid Single-Photon Emission Computed Tomography/Computed Tomography Imaging Features of Tumoral Calcinosis in Technetium-99m Methylene Diphosphonate Bone Scintigraphy.

    Science.gov (United States)

    Kamaleshwaran, Koramadai Karuppusamy; Asokumar, Premkumar; Malaikkal, Anjali; Mohanan, Vyshakh; Shinto, Ajit Sugunan

    2015-01-01

    Tumoral calcinosis (TC) is an uncommon ectopic calcification syndrome. TC is a benign condition characterized by the presence of large calcific soft tissue deposits occurring predominantly in a periarticular location. It generally occurs as a complication of renal dialysis or trauma, and is rarely seen in familial and sporadic cases. Bone scintigraphy is a sensitive method for diagnosing TC. We report a case of year old female with. She underwent bone scintigraphy to see the sites of involvement, which showed intense foci of tracer activity in soft tissue in bilateral thigh and gluteal region. Hybrid single-photon emission computed tomography/computed tomography of the pelvis and thigh localized tracer uptake to the calcification in the gluteal and thigh region.

  4. Spindle cell sarcoma of pulmonary artery mimicking thromboembolism with lung metastasis detected in fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography.

    Science.gov (United States)

    Kamaleshwaran, Koramadai Karuppusamy; Pattabiraman, Vr; Mehta, Sangita; Mohanan, Vyshakh; Shinto, Ajit Sugunan

    2014-10-01

    Pulmonary artery sarcoma (PAS), although rare, must be considered in the differential diagnosis of pulmonary thromboembolism (PTE). This tumor is highly malignant and the prognosis is very poor. As much as the standardized uptake values (SUVs) at fluorine-18 fluorodeoxyglucose positron emission tomography (18F-FDG PET) have helped in differentiating between benign and malignant tumors, visualization of a low-attenuation filling defect within a pulmonary artery on contrast-enhanced chest computed tomography (CT) can be suggestive of a malignancy, such as PAS, if the lesion shows high FDG uptake at PET. We present a case of PAS that showed high FDG uptake on integrated FDG PET/CT and with lung metastasis. Patient underwent endoscopic bronchial ultrasound-transbronchial needle aspiration (EBUS-TBNA), which confirmed spindle cell sarcoma.

  5. Fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography imaging of an isolated subcutaneous loin metastasis from primary papillary carcinoma of the thyroid.

    Science.gov (United States)

    Kamaleshwaran, Koramadai Karuppusamy; Shibu, Deepu; Edathurthy, Radhakrishnan; Shinto, Ajit Sugunan

    2014-04-01

    Differentiated thyroid cancer frequently metastasizes but generally spreads to regional cervical lymph nodes and, in advanced cases, to the lungs and/or skeleton. Metastases to the skin/subcutaneous tissue are rare. We report 45-year-old male patient presented with a loin swelling which on biopsy showed a papillary carcinoma and referred for fluorodeoxyglucose-positron emission tomography/computed tomography (FDG PET/CT) to find out the primary disease. PET/CT showed abnormal FDG uptake within a loin metastasis and right lobe thyroid nodule. Fine-needle aspiration from nodule showed papillary carcinoma. Because thyroid cancer can rarely metastasize to the skin, attention should be given to that region during interpretation of the images. He was advised total thyroidectomy and metastasis excision.

  6. Positron emission tomography of malignant tumours at head and neck. Evaluation of the diagnostic value of positron emission tomography by comparison with computed tomography; Positronenemissionstomographie bei malignen Tumoren im Kopf- und Halsbereich. Beurteilung der diagnostischen Wertigkeit der Positronenemissionstomographie im Vergleich zur Computertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Kettler, Nele

    2011-12-02

    Imaging methods for early, accurate diagnosis and aftercare of malignant growths is currently one of the most important research topics. The objective of this thesis is to evaluate the diagnostic value of FDG-positron emission tomography by comparison with computed tomography for patients with squamous cell carcinoma, malignant melanoma or sarcoma at head and neck. Measurement criteria are sensitivity and specificity. A retrospective evaluation of 100 examinations on 85 patients of University clinic Aachen was performed. The examination reports were supported by reports from histology, positron emission tomography and computed tomography. In each case, the histological results were assumed to provide a reliable benchmark. Sensitivity and specificity for the primary tumour site, metastatic lymphatic nodes and defined anatomic structures were compared across all patients. Comparisons were also performed on sub groups separated by gender, cancer type and the time and frequency at which tumours arose. The statistic analysis was done with MedCalc. Results: The results for sensitivity and specificity of the primary tumour site were 86.42% and 42.86%, and 64.71% and 66.07%, for positron emission tomography and computed tomography respectively. The results for the lymphatic nodes were 51.52% and 92.86% and 64.71% and 66.07%. When the constituent anatomic structures were evaluated separately, the specificity was significantly higher. The separation by gender showed no difference. Because the classification by tumor type resulted in samples that were of varying size, a comparison was difficult. For the diagnosis of primary tumours, the examination with positron emission tomography was superior, whereas computed tomography proved more effective for the diagnosis of recurrent tumours. For the diagnosis of the main tumour site, both methods were shown to be equally suitable. For the assessment of lymphatic nodes, positron emission tomography was superior to computed tomography

  7. Adequacy of compartmental model for positron emission tomography examinations; Adequacao de modelo compartimental para exames de tomografia por emissao de positrons

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Joao Eduardo Maeda Moreira da; Furuie, Sergio Shiguemi [Universidade de Sao Paulo (USP), SP (Brazil). Dept. de Engenharia de Telecomunicacoes e Controle. Lab. de Engenharia Biomedica

    2011-12-15

    The objective of this work is the determination of the most adequate compartmental model for the study of physiological dynamics based on positron emission tomography exams. We propose the use of Akaike's information criterion for the optimal model selection, and Levenberg-Marquardt algorithm with sensitivity equations for the task of estimating the characteristic parameters of the differential equations describing the models. We have considered three compartmental structures represented, respectively, by two compartments and two characteristic constants, three compartments and four characteristic constants and four compartments and six characteristics constants. The data considered in this work were synthesized taking into account key features of a real tomography exam, such as type and level of noise and morphology of the input function of the system. Applying the proposed methodology with three noise levels (low, medium and high), we obtained agreement of the best model with strong and considerable degrees (with Kappa indexes equal to 0.95, 0.93 and 0.63, respectively). It was observed that, with high noise level and more complex models (four compartments), the classification is deteriorated due to lack of data for the decision. Programs have been developed and a graphical interface that can be used in research, development, simulation and parameter identification of compartmental models, supporting analysis of clinical diagnostics and scientific practices. (author)

  8. Second-Generation Triple Reporter for Bioluminescence, Micro–Positron Emission Tomography, and Fluorescence Imaging

    Directory of Open Access Journals (Sweden)

    Aparna H. Kesarwala

    2006-10-01

    Full Text Available Bioluminescence, positron emission tomography (PET, and fluorescence modalities are currently available for noninvasive imaging in vivo, each with its own merits. To exploit the combined strengths of each and facilitate multimodality imaging, we engineered a dual-reporter construct in which firefly luciferase (FLuc and a 12–amino acid nonstructural linker were fused in frame to the N-terminus of a mutant herpes simplex virus thymidine kinase (mNLS-SR39TK kinetically enhanced for positron emission tomography (PET. Furthermore, a triple-reporter construct was developed in which monster green fluorescent protein (MGFP, a recently available enhanced fluorescent protein, was introduced into the fusion vector downstream of an internal ribosome entry site (IRES to allow analysis by fluorescence microscopy or flow cytometry without compromising the specific activities of the upstream fusion components. FLuc bioluminescence was measured with a cooled charge-coupled device camera and mNLS-SR39TK activity by 9-[4-[18F]fluoro-3-(hydroxymethyl butyl guanine (18F-FHBG microPET or 3H-penciclovir net accumulation. Importantly, HeLa cells transiently transfected with the FLuc-mNLS-SR39TK-IRES-MGFP triple reporter retained the same specific activities of the FLuc-mNLS-SR39TK heteroenzyme and the individual unfused enzymes with no change in protein half-lives. The presence of the IRES-MGFP modestly decreased upstream heteroprotein expression. In living mice, somatic gene transfer of a ubiquitin promoter-driven FLuc-mNLS-SR39TK-IRES-MGFP plasmid showed a > 1,000-fold increase in liver photon flux and a > 2-fold increase in liver retention of 18F-FHBG by microPET compared with mice treated with control plasmid. Multifocal hepatocellular fluorescence was readily observed by standard confocal microscopy. This second-generation triple reporter incorporating enhanced components enables bioluminescence, PET, and fluorescence imaging of cells and living animals.

  9. Injectable silver nanosensors: in vivo dosimetry for external beam radiotherapy using positron emission tomography

    Science.gov (United States)

    Christensen, A. N.; Rydhög, J. S.; Søndergaard, R. V.; Andresen, T. L.; Holm, S.; Munck Af Rosenschöld, P.; Conradsen, K.; Jølck, R. I.

    2016-05-01

    Development of safe and efficient radiotherapy routines requires quantification of the delivered absorbed dose to the cancer tissue in individual patients. In vivo dosimetry can provide accurate information about the absorbed dose delivered during treatment. In the current study, a novel silver-nanosensor formulation based on poly(vinylpyrrolidinone)-coated silver nanoparticles formulated in a gelation matrix composed of sucrose acetate isobutyrate has been developed for use as an in vivo dosimeter for external beam radiotherapy. In situ photonuclear reactions trigger the formation of radioactive 106Ag, which enables post treatment verification of the delivered dose using positron emission tomography imaging. The silver-nanosensor was investigated in a tissue equivalent thorax phantom using clinical settings and workflow for both standard fractionated radiotherapy (2 Gy) and stereotactic radiotherapy (10- and 22 Gy) in a high-energy beam setting (18 MV). The developed silver-nanosensor provided high radiopacity on the planning CT-scans sufficient for patient positioning in image-guided radiotherapy and provided dosimetric information about the absorbed dose with a 10% and 8% standard deviation for the stereotactic regimens, 10 and 22 Gy, respectively.Development of safe and efficient radiotherapy routines requires quantification of the delivered absorbed dose to the cancer tissue in individual patients. In vivo dosimetry can provide accurate information about the absorbed dose delivered during treatment. In the current study, a novel silver-nanosensor formulation based on poly(vinylpyrrolidinone)-coated silver nanoparticles formulated in a gelation matrix composed of sucrose acetate isobutyrate has been developed for use as an in vivo dosimeter for external beam radiotherapy. In situ photonuclear reactions trigger the formation of radioactive 106Ag, which enables post treatment verification of the delivered dose using positron emission tomography imaging. The

  10. Fludeoxyglucose positron emission tomography-computed tomography scan showing polyarthritis in a patient with an atypical presentation of Henoch-Schönlein vasculitis without clinical signs of arthritis: a case report.

    Science.gov (United States)

    Mooij, Christiaan F; Hermsen, Rick; Hoppenreijs, Esther P A H; Bleeker-Rovers, Chantal P; IJland, Marloes M; de Geus-Oei, Lioe-Fee

    2016-06-02

    Henoch-Schönlein vasculitis is the most common systemic vasculitis in children. Arthritis or arthralgia occurs in 80 % of patients. We believe this to be the first case report to describe the finding of polyarthritis in a fludeoxyglucose positron emission tomography-computed tomography scan in a patient with Henoch-Schönlein vasculitis without clinical signs of arthritis. A 4.5-year-old Caucasian boy presented with fever of 4 days' duration followed by debilitating migratory arthralgia and inflammation. He underwent a fludeoxyglucose positron emission tomography-computed tomography scan to exclude a possible malignant cause or to detect any infectious or autoimmune focus of his symptoms. Fludeoxyglucose uptake was observed in multiple large joints and in multiple tendons. These findings suggested active polyarthritis and polytendinitis. However, physical and ultrasound evaluations did not show any signs of arthritis in our patient, despite his evident arthralgia. Fludeoxyglucose positron emission tomography-computed tomography might be able to detect inflammatory activity in painful joints that cannot yet be detected clinically or with ultrasound evaluation in a patient with Henoch-Schönlein vasculitis. Therefore, fludeoxyglucose positron emission tomography-computed tomography can be of additional value in the diagnostic workup of patients with an unresolved diagnosis of suspected autoimmune disease, especially in patients with unresolved arthralgia and fever of unknown cause.

  11. Fludeoxyglucose positron emission tomography-computed tomography scan showing polyarthritis in a patient with an atypical presentation of Henoch-Schonlein vasculitis without clinical signs of arthritis: a case report

    NARCIS (Netherlands)

    Mooij, C.F.; Hermsen, Rick; Hoppenreijs, E.P.A.H.; Bleeker-Rovers, C.P.; IJland, M.M.; Geus-Oei, L.F. de

    2016-01-01

    BACKGROUND: Henoch-Schonlein vasculitis is the most common systemic vasculitis in children. Arthritis or arthralgia occurs in 80 % of patients. We believe this to be the first case report to describe the finding of polyarthritis in a fludeoxyglucose positron emission tomography-computed tomography

  12. Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration for Staging of Patients with Non-Small Cell Lung Cancer without Mediastinal Involvement at Positron Emission Tomography-Computed Tomography

    DEFF Research Database (Denmark)

    Naur, Therese Maria Henriette; Konge, Lars; Clementsen, Paul Frost

    2017-01-01

    BACKGROUND: Staging of lung cancer is essential to the treatment, which is curative only in cases of localized disease. Previous studies have suggested that endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is unnecessary when positron emission tomography-computed...... value as 89.6%. CONCLUSIONS: The overall probability of a clinically relevant upstaging by EBUS-TBNA in patients judged as N0/N1 at PET-CT was 6.0%, compared to 0.9% in patients classified as N0 and 17.3% in patients classified as N1. The risk of overlooking N2/N3 disease after both PET-CT and EBUS...

  13. 99m-Tc-ubiquicidin scintigraphy in diagnosis of knee prosthesis infection and comparison with F-18 fluorodeoxy-glucose positron emission tomography/computed tomography.

    Science.gov (United States)

    Kamaleshwaran, Koramadai Karuppusamy; Rajkumar, N; Mohanan, Vyshak; Kalarikal, Radhakrishnan; Shinto, Ajit Sugunan

    2015-01-01

    Total knee arthroplasty has witnessed a significant increase in recent years. Despite the advantages of this surgical procedure, it has some complications, the most serious of which is prosthetic infection. The discrimination of bacterial infections from sterile inflammatory processes is of great importance in the management of periprosthetic infection (PPI). Ubiquicidin (UBI) is a synthetic antimicrobial peptide fragment reported to be highly infection-specific. Tc99m-UBI has recently been reported to be a promising radiotracer for infection imaging. We report a case of left knee PPI diagnosed using 99mTc-UBI scintigraphy and compared with F-18 fluorodeoxy-glucose positron emission tomography.

  14. A Conway-Maxwell-Poisson (CMP) model to address data dispersion on positron emission tomography.

    Science.gov (United States)

    Santarelli, Maria Filomena; Della Latta, Daniele; Scipioni, Michele; Positano, Vincenzo; Landini, Luigi

    2016-10-01

    Positron emission tomography (PET) in medicine exploits the properties of positron-emitting unstable nuclei. The pairs of γ- rays emitted after annihilation are revealed by coincidence detectors and stored as projections in a sinogram. It is well known that radioactive decay follows a Poisson distribution; however, deviation from Poisson statistics occurs on PET projection data prior to reconstruction due to physical effects, measurement errors, correction of deadtime, scatter, and random coincidences. A model that describes the statistical behavior of measured and corrected PET data can aid in understanding the statistical nature of the data: it is a prerequisite to develop efficient reconstruction and processing methods and to reduce noise. The deviation from Poisson statistics in PET data could be described by the Conway-Maxwell-Poisson (CMP) distribution model, which is characterized by the centring parameter λ and the dispersion parameter ν, the latter quantifying the deviation from a Poisson distribution model. In particular, the parameter ν allows quantifying over-dispersion (ν1) of data. A simple and efficient method for λ and ν parameters estimation is introduced and assessed using Monte Carlo simulation for a wide range of activity values. The application of the method to simulated and experimental PET phantom data demonstrated that the CMP distribution parameters could detect deviation from the Poisson distribution both in raw and corrected PET data. It may be usefully implemented in image reconstruction algorithms and quantitative PET data analysis, especially in low counting emission data, as in dynamic PET data, where the method demonstrated the best accuracy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. High-performance computing and networking as tools for accurate emission computed tomography reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Passeri, A. [Dipartimento di Fisiopatologia Clinica - Sezione di Medicina Nucleare, Universita` di Firenze (Italy); Formiconi, A.R. [Dipartimento di Fisiopatologia Clinica - Sezione di Medicina Nucleare, Universita` di Firenze (Italy); De Cristofaro, M.T.E.R. [Dipartimento di Fisiopatologia Clinica - Sezione di Medicina Nucleare, Universita` di Firenze (Italy); Pupi, A. [Dipartimento di Fisiopatologia Clinica - Sezione di Medicina Nucleare, Universita` di Firenze (Italy); Meldolesi, U. [Dipartimento di Fisiopatologia Clinica - Sezione di Medicina Nucleare, Universita` di Firenze (Italy)

    1997-04-01

    It is well known that the quantitative potential of emission computed tomography (ECT) relies on the ability to compensate for resolution, attenuation and scatter effects. Reconstruction algorithms which are able to take these effects into account are highly demanding in terms of computing resources. The reported work aimed to investigate the use of a parallel high-performance computing platform for ECT reconstruction taking into account an accurate model of the acquisition of single-photon emission tomographic (SPET) data. An iterative algorithm with an accurate model of the variable system response was ported on the MIMD (Multiple Instruction Multiple Data) parallel architecture of a 64-node Cray T3D massively parallel computer. The system was organized to make it easily accessible even from low-cost PC-based workstations through standard TCP/IP networking. A complete brain study of 30 (64 x 64) slices could be reconstructed from a set of 90 (64 x 64) projections with ten iterations of the conjugate gradients algorithm in 9 s, corresponding to an actual speed-up factor of 135. This work demonstrated the possibility of exploiting remote high-performance computing and networking resources from hospital sites by means of low-cost workstations using standard communication protocols without particular problems for routine use. The achievable speed-up factors allow the assessment of the clinical benefit of advanced reconstruction techniques which require a heavy computational burden for the compensation effects such as variable spatial resolution, scatter and attenuation. The possibility of using the same software on the same hardware platform with data acquired in different laboratories with various kinds of SPET instrumentation is appealing for software quality control and for the evaluation of the clinical impact of the reconstruction methods. (orig.). With 4 figs., 1 tab.

  16. 18F-fluoro-deoxyglucose positron emission tomography/computed tomography scan findings in Rosai-Dorfman disease with IgG4-positive plasma cell infiltration mimicking breast malignancy: a case report and literature review

    Directory of Open Access Journals (Sweden)

    Fu Liping

    2012-11-01

    Full Text Available Abstract Introduction Rosai-Dorfman disease, also known as sinus histiocytosis with massive lymphadenopathy, is a rare benign disorder characterized histologically by lymphatic sinus dilatation due to histiocyte proliferation. Rosai-Dorfman disease accompanied by IgG4+ plasma cell infiltration is an even rarer situation. To the best of our knowledge, no imaging report of fluoro-deoxyglucose positron emission tomography/computed tomography findings of Rosai-Dorfman disease with IgG4+ plasma cell infiltration has been published, although a series of pathological research has focused on this phenomenon. Case presentation We reviewed the 18F-fluoro-deoxyglucose positron emission tomography/computed tomography scan of a 78-year-old Chinese woman with a solid mass that was found in her right breast during a health checkup. 18F-fluoro-deoxyglucose positron emission tomography/computed tomography showed a hypermetabolic nodule in her right breast and slightly heterogeneous increased fluoro-deoxyglucose uptake of the pulmonary nodules, which were histologically proven to be mammary Rosai-Dorfman disease with IgG4+ plasma cell infiltration and pulmonary amyloidosis, respectively. A literature review was performed to gather information on this rare disease process. Conclusions Although distinguishing benign lymphoplasmacytic proliferation from malignancy may be difficult with 18F-fluoro-deoxyglucose positron emission tomography/computed tomography in light of the pattern and intensity of fluoro-deoxyglucose uptake, our case highlights that whole-body positron emission tomography/computed tomography imaging not only can display the extent of the disease to help complete staging but also can provide functional information about disease activity to guide biopsy.

  17. Imaging of photoassimilates transport in plant tissues by positron emission tomography

    Directory of Open Access Journals (Sweden)

    Partelová Denisa

    2017-06-01

    Full Text Available The current findings show that positron emission tomography (PET, primarily developed for medical diagnostic imaging, can be applied in plant studies to analyze the transport and allocation of wide range of compounds labelled with positronemitting radioisotopes. This work is focused on PET analysis of the uptake and transport of 2-deoxy-2-fluoro[18F]-D-glucose (2-[18F]FDG, as a model of photoassimilates, in tissues of giant reed (Arundo donax L. var. versicolor as a potential energy crop. The absorption of 2-[18F]FDG and its subsequent transport in plant tissues were evaluated in both acropetal and basipetal direction as well. Visualization and quantification of the uptake and transport of 2-[18F]FDG in plants immersed with the root system into a 2-[18F]FDG solution revealed a significant accumulation of 18F radioactivity in the roots. The transport rate in plants was increased in the order of plant exposure through: stem > mechanically damaged root system > intact root system. PET analysis in basipetal direction, when the plant was immersed into the 2-[18F]FDG solution with the cut area of the leaf of whole plant, showed minimal translocation of 2-[18F]FDG into the other plant parts. The PET results were verified by measuring the accumulated radioactivity of 18F by direct gamma-spectrometry.

  18. Cerebral hypometabolism in progressive supranuclear palsy studied with positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Foster, N.L.; Gilman, S.; Berent, S.; Morin, E.M.; Brown, M.B.; Koeppe, R.A.

    1988-09-01

    Progressive supranuclear palsy (PSP) is characterized by supranuclear palsy of gaze, axial dystonia, bradykinesia, rigidity, and a progressive dementia. Pathological changes in this disorder are generally restricted to subcortical structures, yet the type and range of cognitive deficits suggest the involvement of many cerebral regions. We examined the extent of functional impairment to cerebral cortical and subcortical structures as measured by the level of glucose metabolic activity at rest. Fourteen patients with PSP were compared to 21 normal volunteers of similar age using 18F-2-fluoro-2-deoxy-D-glucose and positron emission tomography. Glucose metabolism was reduced in the caudate nucleus, putamen, thalamus, pons, and cerebral cortex, but not in the cerebellum in the patients with PSP as compared to the normal subjects. Analysis of individual brain regions revealed significant declines in cerebral glucose utilization in most regions throughout the cerebral cortex, particularly those in the superior half of the frontal lobe. Declines in the most affected regions of cerebral cortex were greater than those in any single subcortical structure. Although using conventional neuropathological techniques the cerebral cortex appears to be unaffected in PSP, significant and pervasive functional impairments in both cortical and subcortical structures are present. These observations help to account for the constellation of cognitive symptoms in individual patients with PSP and the difficulty encountered in identifying a characteristic psychometric profile for this group of patients.

  19. 2-18F-fluoro-2-deoxyglucose positron emission tomography in delirium.

    Science.gov (United States)

    Haggstrom, Lucy R; Nelson, Julia A; Wegner, Eva A; Caplan, Gideon A

    2017-11-01

    Delirium is a common, serious, yet poorly understood syndrome. Growing evidence suggests cerebral metabolism is fundamentally disturbed; however, it has not been investigated using 2-18F-fluoro-2-deoxyglucose (FDG) positron emission tomography (PET) in delirium. This prospective study thus explored FDG PET patterns of cerebral glucose metabolism in older inpatients with delirium. A particular emphasis was on the posterior cingulate cortex (PCC), a key region for attention, which is a central feature of delirium. Delirium scans were compared with post-delirium scans using visual analysis and semi-quantitative analysis with NeuroQ; 13 participants (8 female, median 84 y) were scanned during delirium, and 6 scanned again after resolution. On visual analysis, cortical hypometabolism was evident in all participants during delirium (13/13), and improved with delirium resolution (6/6). Using NeuroQ, glucose metabolism was higher post-delirium in the whole brain and bilateral PCC compared to during delirium ( p delirium duration. This research found widespread, reversible cortical hypometabolism during delirium and PCC hypometabolism was associated with inattention during delirium.

  20. Silicon photomultipliers for positron emission tomography detectors with depth of interaction encoding capability

    Energy Technology Data Exchange (ETDEWEB)

    Taghibakhsh, Farhad, E-mail: farhadt@sri.utoronto.ca [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Thunder Bay Regional Health Science Centre, Thunder Bay, ON (Canada); Reznik, Alla [Thunder Bay Regional Health Science Centre, Thunder Bay, ON (Canada); Department of Physics, Lake Head University, Thunder Bay, ON (Canada); Rowlands, John A. [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Thunder Bay Regional Health Science Centre, Thunder Bay, ON (Canada); Department of Physics, Lake Head University, Thunder Bay, ON (Canada)

    2011-05-15

    Silicon photomultipliers (SiPMs) are receiving increasing attention in the field of positron emission tomography (PET) detectors. Compared to photomultiplier tubes, they offer novel detector configurations for the extraction of depth of interaction (DOI) information, or enable emerging medical imaging modalities such as simultaneous PET-magnetic resonant imaging (MRI). In this article, we used 2x2x20 mm{sup 3} LYSO scintillator crystals coupled to SiPMs on both ends (dual-ended readout configuration) to evaluate the detector performance for DOI-PET applications. We investigated the effect of scintillator crystal surface finishing on sensitivity and resolution of DOI, as well as on energy and timing resolution. Measurements indicate DOI sensitivity and resolution of 7.1% mm{sup -1} and 2.1{+-}0.6 mm for saw-cut, and 1.3% mm{sup -1} and 9.0{+-}1.5 mm, for polished scintillator crystals, respectively. Energy resolution varies from 19% when DOI is in the center, to 15% with DOI at either end of the saw-cut crystal, while it remains constant at {approx}14% for polished scintillators. Based on our results we conclude that 2x2x20 mm{sup 3} saw-cut (without any special side wall polishing) LYSO crystals coupled to 2x2 mm{sup 2} silicon photomultipliers are optimal for isotropic 2 mm resolution DOI-PET applications.

  1. Positron emission tomography molecular imaging of dopaminergic system in drug addiction.

    Science.gov (United States)

    Hou, Haifeng; Tian, Mei; Zhang, Hong

    2012-05-01

    Dopamine (DA) is involved in drug reinforcement, but its role in drug addiction remains unclear. Positron emission tomography (PET) is the first technology used for the direct measurement of components of the dopaminergic system in the living human brain. In this article, we reviewed the major findings of PET imaging studies on the involvement of DA in drug addiction, especially in heroin addiction. Furthermore, we summarized PET radiotracers that have been used to study the role of DA in drug addiction. To investigate presynaptic function in drug addiction, PET tracers have been developed to measure DA synthesis and transport. For the investigation of postsynaptic function, several radioligands targeting dopamine one (D1) receptor and dopamine two (D2) receptor are extensively used in PET imaging studies. Moreover, we also summarized the PET imaging findings of heroin addiction studies, including heroin-induced DA increases and the reinforcement, role of DA in the long-term effects of heroin abuse, DA and vulnerability to heroin abuse and the treatment implications. PET imaging studies have corroborated the role of DA in drug addiction and increase our understanding the mechanism of drug addiction. Copyright © 2012 Wiley Periodicals, Inc.

  2. Incidental finding of a left over guide wire on a positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yap, Kok Hooi; Lee, Phong Teck; Buch, Mamta; Rammohan, Kandadai Seshadri

    2012-12-15

    The Seldinger technique is commonly used cannulate vessels for radiographical procedures. Loss of a guide wire into the circulation is a rare and preventable complication. It is often noticed by chance during routine radiographs. However, there is a lack of reported cases of incidental fin dings of leftover guide wire on a PET scan. An intravascular foreign body should be retrieved as soon as the diagnosis is made, to prevent complications such as embolisation or vascular damage by fractured wires. Interventional radiology is the method of choice for retrieval. We report a rare case of the coincidental finding of a lost guide wire on a PET scan. A 37 year old man presented with psychotic episodes, thigh weakness, weight gain, increased appetite and leg cramps. He was subsequently diagnosed with cushing syndrome secondary to ectopic adrenocorticotropic secretion from a right lung tumour. He subsequently underwent a staging positron emission tomography (PET) scan. The lung tumour had no uptake on PET bit had increased activity uptake on octreotide scanning. These appearances were suggestive of with carcinoid tumour. The PET scan also revealed an incidental finding of a leftover guide wire used during peripheral inserted central catheter (PICC) recently. The wire extended from right atrium to inferior vena cava. It also showed a high uptake in the adrenal glands, indicating hyperplasia, which was most likely due to adrenocorticotropic hormone stimulation. He underwent a percutaneous wire retrieval via the right femoral vein in a cardiac catheterisation laboratory and was transferred to a thoracic surgical unit for lung tumor resection.

  3. Amyloid and metabolic positron emission tomography imaging of cognitively normal adults with Alzheimer's parents

    DEFF Research Database (Denmark)

    Mosconi, Lisa; Rinne, Juha O; Tsui, Wai H

    2013-01-01

    , voxel-wise intermodality correlations, and logistic regressions were used to examine cerebral-to-cerebellar PiB and FDG standardized uptake value ratios across groups. The MH group showed higher PiB retention and lower metabolism in AD regions compared with NH and PH, which were negatively correlated...... emission tomography (PET) with (11)C-Pittsburgh compound B (PiB) and 18F-fluoro-2-deoxy-d-glucose (FDG). These included 19 NL with a maternal history (MH), 12 NL with a paternal history (PH), and 16 NL with negative family history of AD (NH). Automated regions of interest, statistical parametric mapping...... in posterior cingulate, frontal, and parieto-temporal regions (Pearson r ≤ -0.57, p ≤ 0.05). No correlations were observed in NH and PH. The combination of Aβ deposition and metabolism yielded accuracy ≥ 69% for MH vs. NH and ≥ 71% for MH vs. PH, with relative risk = 1.9-5.1 (p values

  4. AMG 580: a novel small molecule phosphodiesterase 10A (PDE10A) positron emission tomography tracer.

    Science.gov (United States)

    Chen, Hang; Lester-Zeiner, Dianna; Shi, Jianxia; Miller, Silke; Glaus, Charlie; Hu, Essa; Chen, Ning; Able, Jessica; Biorn, Christopher; Wong, Jamie; Ma, Ji; Michelsen, Klaus; Hill Della Puppa, Geraldine; Kazules, Tim; Dou, Hui Hannah; Talreja, Santosh; Zhao, Xiaoning; Chen, Ada; Rumfelt, Shannon; Kunz, Roxanne K; Ye, Hu; Thiel, Oliver R; Williamson, Toni; Davis, Carl; Porter, Amy; Immke, David; Allen, Jennifer R; Treanor, James

    2015-02-01

    Phosphodiesterase 10A (PDE10A) inhibitors have therapeutic potential for the treatment of psychiatric and neurologic disorders, such as schizophrenia and Huntington's disease. One of the key requirements for successful central nervous system drug development is to demonstrate target coverage of therapeutic candidates in brain for lead optimization in the drug discovery phase and for assisting dose selection in clinical development. Therefore, we identified AMG 580 [1-(4-(3-(4-(1H-benzo[d]imidazole-2-carbonyl)phenoxy)pyrazin-2-yl)piperidin-1-yl)-2-fluoropropan-1-one], a novel, selective small-molecule antagonist with subnanomolar affinity for rat, primate, and human PDE10A. We showed that AMG 580 is suitable as a tracer for lead optimization to determine target coverage by novel PDE10A inhibitors using triple-stage quadrupole liquid chromatography-tandem mass spectrometry technology. [(3)H]AMG 580 bound with high affinity in a specific and saturable manner to both striatal homogenates and brain slices from rats, baboons, and human in vitro. Moreover, [(18)F]AMG 580 demonstrated prominent uptake by positron emission tomography in rats, suggesting that radiolabeled AMG 580 may be suitable for further development as a noninvasive radiotracer for target coverage measurements in clinical studies. These results indicate that AMG 580 is a potential imaging biomarker for mapping PDE10A distribution and ensuring target coverage by therapeutic PDE10A inhibitors in clinical studies. Copyright © 2015 by The American Society for Pharmacology and Experimental Therapeutics.

  5. Positron-emission tomography of brain regions activated by recognition of familiar music.

    Science.gov (United States)

    Satoh, M; Takeda, K; Nagata, K; Shimosegawa, E; Kuzuhara, S

    2006-05-01

    We can easily recognize familiar music by listening to only one or 2 of its opening bars, but the brain regions that participate in this cognitive processing remain undetermined. We used positron-emission tomography (PET) to study changes in regional cerebral blood flow (rCBF) that occur during listening to familiar music. We used a PET subtraction technique to elucidate the brain regions associated with the recognition of familiar melodies such as well-known nursery tunes. Nonmusicians performed 2 kinds of musical tasks: judging the familiarity of musical pieces (familiarity task) and detecting deliberately altered notes in the pieces (alteration-detecting task). During the familiarity task, bilateral anterior portions of bilateral temporal lobes, superior temporal regions, and parahippocampal gyri were activated. The alteration-detecting task bilaterally activated regions in the precunei, superior/inferior parietal lobules, and lateral surface of frontal lobes, which seemed to show a correlation with the analysis of music. We hypothesize that during the familiarity task, activated brain regions participate in retrieval from long-term memory and verbal and emotional processing of familiar melodies. Our results reinforced the hypothesis reported in the literature as a result of group and case studies, that temporal lobe regions participate in the recognition of familiar melodies.

  6. Wavelength swept amplified spontaneous emission source for high speed retinal optical coherence tomography at 1060 nm.

    Science.gov (United States)

    Eigenwillig, Christoph M; Klein, Thomas; Wieser, Wolfgang; Biedermann, Benjamin R; Huber, Robert

    2011-08-01

    The wavelength swept amplified spontaneous emission (ASE) source presented in this paper is an alternative approach to realize a light source for high speed swept source optical coherence tomography (OCT). ASE alternately passes a cascade of different optical gain elements and tunable optical bandpass filters. In this work we show for the first time a wavelength swept ASE source in the 1060 nm wavelength range, enabling high speed retinal OCT imaging. We demonstrate ultra-rapid retinal OCT at a line rate of 170 kHz, a record sweep rate at 1060 nm of 340 kHz with 70 nm full sweep width, enabling an axial resolution of 11 μm. Two different implementations of the source are characterized and compared to each other. The last gain element is either a semiconductor optical amplifier or an Ytterbium-doped fibre amplifier enabling high average output power of >40 mW. Various biophotonic imaging examples provide a wide range of quality benchmarks achievable with such sources. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. [(18F]Fluoroethyltyrosine- positron emission tomography-guided radiotherapy for high-grade glioma

    Directory of Open Access Journals (Sweden)

    Ratib Osman

    2008-12-01

    Full Text Available Abstract Background To compare morphological gross tumor volumes (GTVs, defined as pre- and postoperative gadolinium enhancement on T1-weighted magnetic resonance imaging to biological tumor volumes (BTVs, defined by the uptake of 18F fluoroethyltyrosine (FET for the radiotherapy planning of high-grade glioma, using a dedicated positron emission tomography (PET-CT scanner equipped with three triangulation lasers for patient positioning. Methods Nineteen patients with malignant glioma were included into a prospective protocol using FET PET-CT for radiotherapy planning. To be eligible, patients had to present with residual disease after surgery. Planning was performed using the clinical target volume (CTV = GTV ∪ BTV and planning target volume (PTV = CTV + 20 mm. First, the interrater reliability for BTV delineation was assessed among three observers. Second, the BTV and GTV were quantified and compared. Finally, the geometrical relationships between GTV and BTV were assessed. Results Interrater agreement for BTV delineation was excellent (intraclass correlation coefficient 0.9. Although, BTVs and GTVs were not significantly different (p = 0.9, CTVs (mean 57.8 ± 30.4 cm3 were significantly larger than BTVs (mean 42.1 ± 24.4 cm3; p 3; p Conclusion Using FET, the interrater reliability had excellent agreement for BTV delineation. With FET PET-CT planning, the size and geometrical location of GTVs and BTVs differed in a majority of patients.

  8. Gliomatosis cerebri evaluated by {sup 18}F{alpha}-methyl tyrosine positron-emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sato, N.; Aoki, J. [Department of Diagnostic Radiology, Gunma University School of Medicine (Japan); Inoue, T. [Department of Radiology, Yokohama City University, Yokohama (Japan); Tomiyoshi, K.; Oriuchi, N.; Endo, K. [Department of Nuclear Medicine, Gunma University School of Medicine, Maebashi, Gunma (Japan); Takahashi, A.; Otani, T.; Kurihara, H.; Sasaki, T. [Department of Neurosurgery, Gunma University School of Medicine, Maebashi, Gunma (Japan)

    2003-10-01

    Gliomatosis cerebri is a rare condition in which an infiltrative glial neoplasm spreads through the brain with preservation of the underlying structure. CT and MRI show diffuse abnormal density or signal, without mass effect, and because these findings are nonspecific, it is difficult to make a definitive diagnosis. Our purpose was to assess the usefulness of a new tumour-detecting amino acid tracer for positron-emission tomography (PET), L-[3-{sup 18}F] {alpha}-methyl tyrosine (FMT), in patients with gliomatosis cerebri. We performed FMT PET, fluorodeoxyglucose FDG PET and MRI eight patients with gliomatosis cerebri and six with non-neoplastic disease, whose MRI also showed diffuse high signal on T2-weighted images. Standardised uptake (SUV) of FMT and FDG in the area of gliomatosis was obtained and the tumour-to-normal cortex (T/N) ratio of this was compared. The tumours were shown on FMT PET as areas of increased uptake, except in one patient with severe intracranial hypertension. There were significant differences between the SUV of FMT and the T/N ratio of FMT in patients and in controls (both P<0.01), and between the T/N ratio of FMT and FDG in patients (P <0.01). Increased uptake of FMT PET strongly suggests neoplasia. FMT PET is valuable for differentiating gliomatosis cerebri from non-neoplastic diseases showing similar diffuse high signal on T2-weighted images and little contrast enhancement. (orig.)

  9. Assessment of myocardial metabolism by positron emission tomography; Stoffwechseluntersuchungen des Herzens mit der Positronenemissionstomographie

    Energy Technology Data Exchange (ETDEWEB)

    Bengel, F.M.; Schwaiger, M. [Technische Univ. Muenchen (Germany). Nuklearmedizinische Klinik und Poliklinik

    1999-06-01

    In combination with a variety of tracers, positron emission tomography does provide noninvasive quantitative information not only about myocardial utilisation of substrates such as glucose or free fatty acids, but also about overall oxidative metabolism. PET studies of myocardial metabolism have substantially contributed to an improved understanding of regulatory mechanism as well as interaction between different substrates under normal conditions as well as under pathologic conditions such as ischemia, heart failure or diabetes mellitus, and will continue to do so in the future. (orig.) [German] Fuer die Positronenemissionstomographie stehen verschiedene Tracer zur Verfuegung, die am menschlichen Herzen nichtinvasive Quantifizierung der Utilisation von Substraten wie Glukose oder freien Fettsaeuren, aber auch des gesamten sauerstoffabhaengigen Metabolismus ermoeglichen. Stoffwechseluntersuchungen des Herzens mit der PET haben zu einem genaueren Verstaendnis von Regulationsmechanismen und Interaktionen zwischen verschiedenen Substraten sowohl im Normalzustand als auch unter pathologischen Bedingungen wie etwa bei ischaemischen Syndromen, Herzinsuffizienz oder Diabetis mellitus beigetragen. Insbesondere durch Untersuchungen von metabolischen Auswirkungen verschiedener Therapieansaetze bei Herzerkrankungen und zur Vorhersage der Effektivitaet solcher therapeutischer Strategien kann die PET auch in Zukunft einen Beitrag zur Weiterentwicklung der Kardiologie leisten. (orig.)

  10. Assessment of Cancer-Associated Biomarkers by Positron Emission Tomography: Advances and Challenges

    Directory of Open Access Journals (Sweden)

    T. Lee Collier

    2002-01-01

    Full Text Available Positron emission tomography (PET provides a powerful means to non-invasively image and quantify protein expression and biochemical changes in living subjects at nano- and picomolar levels. As the field of molecular imaging develops, and as advances in the biochemistry, pharmacology, therapeutics, and molecular biology of disease are made, there is a corresponding increase in the number of clinically relevant, novel disease-associated biomarkers that are brought to the attention of those developing imaging probes for PET. In addition, due to the high specificity of the PET radiotracers being developed, there is a demand for PET cameras with higher sensitivity and resolution. This manuscript reviews advances over the past five years in clinical and pre-clinical PET instrumentation and in new PET probes and imaging methods associated with the latest trends in the molecular imaging of cancer. Included in the PET tracer review is a description of new radioligands for steroid receptors, growth factor receptors, receptor tyrosine kinases, sigma receptors, tumor-associated enzymes, gene reporter probes, markers for tumor hypoxia and metabolism, and sites associated with angiogenesis and cellular proliferation. The use of PET imaging in drug development, including the monitoring of cancer chemotherapy, also is discussed.

  11. A behavioral and micro positron emission tomography imaging study in a rat model of hypothyroidism.

    Science.gov (United States)

    Yu, Jing; Tang, Yi-Yuang; Feng, Hong-Bo; Cheng, Xiao-Xin

    2014-09-01

    Hypothyroidism leads to somatic, neuropsychological, and psychiatric changes that are similar to depression. The mechanisms underlying the behavioral abnormalities in adult onset hypothyroidism remain ambiguous. Hypothyroidism was induced in adult male Wistar rats by the maintenance of 0.05% propylthiouracil (PTU) in drinking water for 5 weeks (hypothyroid group; HP group); control rats (CON group) received an equivalent amount of water. The open field and sucrose preference tests were employed, and the link between behavioral changes and brain glucose metabolism was evaluated using micro positron emission tomography imaging. The open field test revealed slightly decreased locomotor activity and significantly reduced rearing and defecation in the hypothyroid group. Hypothyroid rats were also characterized by decreased body weight, sucrose preference, and relative sucrose intake compared to control rats. Hypothyroidism induced reduced brain glucose metabolism in the bilateral motor cortex, the caudate putamen, the cortex cingulate, the nucleus accumbens, and the frontal association cortex. A decreased sucrose preference was positively correlated with metabolic glucose changes in the caudate putamen and the nucleus accumbens. The results indicate that the activity pattern in adult onset hypothyroidism is different from the activity pattern when hypothyroidism is induced in the developmental period of the central nervous system. Decreased sucrose preference in hypothyroid rats may be attributed to anhedonia. Furthermore, these findings suggest there may be a common mechanism underlying adult onset hypothyroidism and depression. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Localization of post-infarction myocardial ischemia by /sup 201/Tl emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Spielmann, R.P.; Heinemann, H.; Montz, R.; Nienaber, C.A.

    1985-12-01

    In 41 patients with a history of a single myocardial infarction, the location of myocardial ischemia was studied by /sup 201/Tl emission computed tomography immediately and 3 h after intravenous dipyridamole. Peri-infarctional ischemia without distant ischemia was observed in 15 patients. The occurrence of distant ischemia was found to be dependent on the severity of stenosis in non-infarct coronary vessels. Twelve (86%) of 14 patients with non-infarct stenosis of 75% or greater had distant ischemia, but only 1 (4%) of 27 patients with non-infarct stenosis of less than 75%. In the presence of distant ischemia, peri-infarctional ischemia was in 11 patients (85%) associated with collaterals supplying the infarct zone, whereas in 13 (87%) of the patients with peri-infarctional ischemia only, incomplete obstruction of the infarct vessel was observed. It is concluded that, by the distinction between peri-infarctional and distant ischemia, the presence of significant stenosis in non-infarct vessels can be non-invasively predicted from tomographic thallium scintigraphy with dipyridamole.

  13. Cerebral glucose utilization in pediatric neurological disorders determined by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yanai, Kazuhiko; Iinuma, Kazuie; Miyabayashi, Shigeaki; Narisawa, Kuniaki; Tada, Keiya; Matsuzawa, Taiju; Ito, Masatoshi; Yamada, Kenji

    1987-09-01

    We measured local cerebral glucose utilization in 19 patients with Lennox-Gastaut syndrome (LG), partial seizures (PS), atypical and classical phenylketonuria (PKU), Leigh disease, and subacute sclerosing panencephalitis (SSPE), using positron emission tomography (PET). The mean values of regional glucose utilization in interictal scans of LG were significantly reduced in all brain regions when compared with that of PS (P<0.005). PET studies of glucose utilization in LG revealed more widespread hypometabolism than in PS. Two sibling with dihydropteridine reductase deficiency, a patient with classical PKU, and a boy with cytochrome c oxidase deficiency showed reduced glucose utilization in the caudate and putamen. A marked decrease in glucose utilization was found in the cortical gray matter of a patient with rapidly progressive SSPE, despite relatively preserved utilization in the caudate and putamen. The PET study of a patient with slowly progressive SSPE revealed patterns and values of glucose utilization similar to those of the control. Thus, PET provided a useful clue toward understanding brain dysfunction in LG, PS, PKU, Leigh disease, and SSPE.

  14. Detection of unknown primary head and neck tumors by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Braams, J.W.; Roodenburg, J.L.N. [Groningen Univ. Hospital, Dept. of Oral and Maxillofacial Surgery, Groningen (Netherlands); Pruim, J.; Vaalburg, W.; Kole, A.C. [Groningen Univ. Hospital, PET center, Groningen (Netherlands); Vermey, A. [Groningen Univ. Hospital, Dept. of Surgical Oncology, Groningen (Netherlands); Nikkels, P.G.J. [Groningen Univ. Hospital, Dept. of Pathology, Groningen (Netherlands)

    1997-04-01

    The purpose of this study was to investigate the potential of using positron emission tomography (PET) with {sup 18}F-labeled fluoro-2-deoxy-D-glucose (FDG) to detect unknown primary tumors of cervical metastases. Thirteen patients with various histologic types of cervical metastases of unknown primary origin were studied. Patients received 185-370 MBq FDG intravenously and were scanned from 30 min after injection onward. Whole-body scans were made with a Siemens ECAT 951/31 PET camera. PET identified the primary tumor in four patients: plasmocytoma, squamous cell cacinoma of the oropharynx, squamous cell carcinoma of the larynx, and bronchial carcinoma, respectively. All known metastatic tumor sites were visualized. PET did not identify a primary tumor in one patient in whom a squamous cell carcinoma at the base of the tongue was found in a latr phase. In the remaining eight patients, a primary lesion was never found. The follow up ranged from 18 to 30 months. A previously unknown primary tumor can be identified with FDG-PET in approximately 30% of patients with cervical metastases. PET can reveal useful information that results in more appropriate treatment, and it can be of value in guiding endoscopic biopsies for histologic diagnosis. (au).

  15. Numerical study on simultaneous emission and transmission tomography in the MRI framework

    Science.gov (United States)

    Gjesteby, Lars; Cong, Wenxiang; Wang, Ge

    2017-09-01

    Multi-modality imaging methods are instrumental for advanced diagnosis and therapy. Specifically, a hybrid system that combines computed tomography (CT), nuclear imaging, and magnetic resonance imaging (MRI) will be a Holy Grail of medical imaging, delivering complementary structural/morphological, functional, and molecular information for precision medicine. A novel imaging method was recently demonstrated that takes advantage of radiotracer polarization to combine MRI principles with nuclear imaging. This approach allows the concentration of a polarized Υ-ray emitting radioisotope to be imaged with MRI resolution potentially outperforming the standard nuclear imaging mode at a sensitivity significantly higher than that of MRI. In our work, we propose to acquire MRI-modulated nuclear data for simultaneous image reconstruction of both emission and transmission parameters, suggesting the potential for simultaneous CT-SPECT-MRI. The synchronized diverse datasets allow excellent spatiotemporal registration and unique insight into physiological and pathological features. Here we describe the methodology involving the system design with emphasis on the formulation for tomographic images, even when significant radiotracer signals are limited to a region of interest (ROI). Initial numerical results demonstrate the feasibility of our approach for reconstructing concentration and attenuation images through a head phantom with various radio-labeled ROIs. Additional considerations regarding the radioisotope characteristics are also discussed.

  16. Brain positron emission tomography in patients with myotonic dystrophy type 1 and type 2.

    Science.gov (United States)

    Peric, Stojan; Brajkovic, Leposava; Belanovic, Bozidar; Ilic, Vera; Salak-Djokic, Biljana; Basta, Ivana; Rakocevic Stojanovic, Vidosava

    2017-07-15

    To determine regions of reduced brain metabolism in patients with myotonic dystrophy type 1 (DM1) and type 2 (DM2) using 18F-fluoro-2-deoxy-d-glucose positron emission tomography (FDG-PET), and to analyse their potential association with cognitive deficit. Study included 29 patients (16 DM1 and 13 DM2). FDG-PET and detailed neuropsychological testing were performed in both groups. The most common cognitive findings were executive, visuospatial, and naming dysfunction in DM1, and executive and naming dysfunction in DM2. FDG-PET showed the most prominent glucose hypometabolism in prefrontal, temporal, and pericentral regions in both DM1 and DM2 patients, with additional affection of insula and subcortical grey matter in DM2. In DM1 patients, we found association between right frontotemporal hypometabolism and executive dysfunction (pDM2 patients attention deficit was in association with prefrontal, insular, and striatal hypometabolism, as well as right frontotemporal hypometabolism (pDM2 was more common in patients with prefrontal and insular hypometabolism, right parietotemporal and frontotemporal hypometabolism, as well as left striatal hypometabolism (pDM2, but this hypothesis will have to be more strongly supported by larger studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Cerebello-cerebral functional relationship in spinocerebellar degeneration using positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Koshi, Yasuhiko; Kitamura, Shin; Sakayori, Osamu; Komaba, Yuichi; Terashi, Akiro [Nippon Medical School, Tokyo (Japan)

    1995-07-01

    In order to investigate the laterality of cerebellar ataxia and its influence for the cerebral cortex in spinocerebellar degeneration (SCD), regional cerebral blood flow (rCBF) was measured using positron emission tomography (PET) in 10 patients with sporadic olivopontocerebellar atrophy (sOPCA), 7 patients with hereditary SCD (hSCD), and 10 age matched control subjects. The laterality of cerebellar ataxia was evaluated by the total score of the difference between left and right limbs of three limb-coordination tests. The lateralities of rCBF were calculated by asymmetry indices (AIs) of each region of interest in the cerebellum, thalamus, caudate, putamen, cerebral cortices. The laterality of cerebellar ataxia was significantly correlated with AI in the cerebellum in patients with sOPCA. Furthermore, significant negative correlations were observed between AI in the cerebellum and each AI in the thalamus, frontal cortex in patients with sOPCA. However, no correlations were observed between AI in the cerebellum and the other AIs in controls and patients with h SCD. Duration of illness in patients with sOPCA with laterality is shorter than that in patients without laterality. These results suggest that the existence of crossed cerebello-cerebral diaschisis (CCCD) resulting from transneuronal deactivation through cerebello-thalamo-cerebral pathway in patients with the early stage of sOPCA with laterality. (author).

  18. Function of the shoulder muscles during arm elevation: an assessment using positron emission tomography

    Science.gov (United States)

    Omi, Rei; Sano, Hirotaka; Ohnuma, Masahiro; Kishimoto, Koshi N; Watanuki, Shoichi; Tashiro, Manabu; Itoi, Eiji

    2010-01-01

    Although 2-deoxy-2-[18F]fluoro-D-glucose (FDG) positron emission tomography (PET) has been used for the assessment of skeletal muscle activities, its application to the shoulder muscles is only sparse. The purpose of this study was to investigate the activities of the shoulder muscles during arm elevation using PET. Six healthy volunteers performed an arm elevation exercise before and after FDG injection. The exercise consisted of 200 repetitions of arm elevation in the scapular plane with a 0.25-kg weight fixed to the wrist on both arms. PET examination was performed 50 min after FDG injection. For control data, PET scan was repeated for each subject on a separate day without any exercise. The volume of interest was established for each shoulder muscle. The subscapularis was divided into three portions (superior, middle, and inferior). The standardized uptake value (SUV) was calculated in each muscle to quantify its activity. The SUVs increased significantly after exercise in the deltoid, supraspinatus, and the superior portion of subscapularis. Among three divided portions of the subscapularis, the SUV of the superior one-third was significantly greater than the rest of the muscle after exercise. Our current study clearly indicated that there were two functionally different portions in the subscapularis muscle and the superior one-third played an important role during arm elevation in the scapular plane. PMID:20298439

  19. Aspects of positron emission tomography radiochemistry as relevant for food chemistry.

    Science.gov (United States)

    Wuest, F

    2005-12-01

    Positron emission tomography (PET) is a medical imaging technique using compounds labelled with short-lived positron emitting radioisotopes to obtain functional information of physiological, biochemical and pharmacological processes in vivo. The need to understand the potential link between the ingestion of individual dietary agents and the effect of health promotion or health risk requires the exact metabolic characterization of food ingredients in vivo. This exciting but rather new research field of PET would provide new insights and perspectives on food chemistry by assessing quantitative information on pharmocokinetics and pharmacodynamics of food ingredients and dietary agents. To fully exploit PET technology in food chemistry appropriately radiolabelled compounds as relevant for food sciences are needed. The most widely used short-lived positron emitters are (11)C (t(1/2) = 20.4 min) and (18)F (t(1/2) = 109.8 min). Longer-lived radioisotopes are available by using (76)Br (t(1/2) = 16.2 h) and (124)I (t(1/2) = 4.12 d). The present review article tries to discuss some aspects for the radiolabelling of food ingredients and dietary agents either by means of isotopic labelling with (11)C or via prosthetic group labelling approaches using the positron emitting halogens (18)F, (76)Br and (124)I.

  20. Brain Metabolism of Less-Educated Patients With Alzheimer Dementia Studied by Positron Emission Tomography.

    Science.gov (United States)

    Huang, Yu Ching; Yen, Pao Sheng; Wu, Shwu Tzy; Chen, Jung Tai; Hung, Gung Uei; Kao, Chia Hung; Chen, Tai Yee; Ho, Feng Ming

    2015-07-01

    Alzheimer dementia (AD) is the commonest form of dementia. Although illiteracy is associated with high prevalence of dementia of the Alzheimer type (DAT), their relationship is still unclear. Nevertheless, mild DAT in illiterate participants seems to be due to brain atrophy.In this study, we compared the impact of brain metabolism efficiency in healthy participants and less-educated patients with mild DAT using 2-fluoro-2-deoxy-D-glucose (F-FDG-PET) positron emission tomography. Out of 43 eligible less-educated participants with dementia, only 23 (14 women and 9 men) met Diagnostic and Statistical Manual (DSM)-III-R or DSM-IV criteria for DAT and AD and were included. Participants with intracranial insults were excluded by brain magnetic resonance imaging and participants with metabolic or systemic conditions were excluded by blood sampling. In addition, 16 cognitively normal elderly (age >70 years), including 7 women and 9 men, were enrolled in the sham group. The PET imaging data were analyzed using statistical parametric mapping (SPM8) to determine reliability and specificity.Glucose metabolic rate was low in the DAT group, especially in the middle temporal gyrus, middle frontal gyrus, superior frontal gyrus, inferior frontal gyrus, posterior cingulate gyrus, angular gyrus, parahippocampal gyrus, middle occipital gyrus, rectal gyrus, and lingual gyrus.Our results showed that DAT patients with less education not only have prominent clinical signs and symptoms related to dementia but also decreased gray matter metabolism.

  1. Re-Evaluation of Clinical Dementia Diagnoses with Pittsburgh Compound B Positron Emission Tomography

    Directory of Open Access Journals (Sweden)

    M. Degerman Gunnarsson

    2013-12-01

    Full Text Available Objectives: There is an overlap regarding Pittsburgh compound B (PIB retention in patients clinically diagnosed as Alzheimer's disease (AD and non-AD dementia. The aim of the present study was to investigate whether there are any differences between PIB-positive and PIB-negative patients in a mixed cohort of patients with neurodegenerative dementia of mild severity regarding neuropsychological test performance and regional cerebral glucose metabolism measured with [18F]fluoro-2-deoxy-D-glucose (FDG positron emission tomography (PET. Methods: Eighteen patients clinically diagnosed as probable AD or frontotemporal dementia were examined with PIB PET, FDG PET and neuropsychological tests and followed for 5-9 years in a clinical setting. Results: The PIB-positive patients (7 out of 18 had slower psychomotor speed and more impaired visual episodic memory than the PIB-negative patients; otherwise performance did not differ between the groups. The initial clinical diagnoses were changed in one third of the patients (6 out of 18 during follow-up. Conclusions: The subtle differences in neuropsychological performance, the overlap of hypometabolic patterns and clinical features between AD and non-AD dementia highlight the need for amyloid biomarkers and a readiness to re-evaluate the initial diagnosis.

  2. A fast rebinning algorithm for 3D positron emission tomography using John's equation

    Science.gov (United States)

    Defrise, Michel; Liu, Xuan

    1999-08-01

    Volume imaging in positron emission tomography (PET) requires the inversion of the three-dimensional (3D) x-ray transform. The usual solution to this problem is based on 3D filtered-backprojection (FBP), but is slow. Alternative methods have been proposed which factor the 3D data into independent 2D data sets corresponding to the 2D Radon transforms of a stack of parallel slices. Each slice is then reconstructed using 2D FBP. These so-called rebinning methods are numerically efficient but are approximate. In this paper a new exact rebinning method is derived by exploiting the fact that the 3D x-ray transform of a function is the solution to the second-order partial differential equation first studied by John. The method is proposed for two sampling schemes, one corresponding to a pair of infinite plane detectors and another one corresponding to a cylindrical multi-ring PET scanner. The new FORE-J algorithm has been implemented for this latter geometry and was compared with the approximate Fourier rebinning algorithm FORE and with another exact rebinning algorithm, FOREX. Results with simulated data demonstrate a significant improvement in accuracy compared to FORE, while the reconstruction time is doubled. Compared to FOREX, the FORE-J algorithm is slightly less accurate but more than three times faster.

  3. A promising new mechanism of ionizing radiation detection for positron emission tomography: Modulation of optical properties

    Science.gov (United States)

    Tao, Li; Daghighian, Henry M.; Levin, Craig S.

    2016-01-01

    Using conventional scintillation detection, the fundamental limit in positron emission tomography (PET) time resolution is strongly dependent on the inherent temporal variances generated during the scintillation process, yielding an intrinsic physical limit for the coincidence time resolution of around 100 ps. On the other hand, modulation mechanisms of the optical properties of a material exploited in the optical telecommunications industry can be orders of magnitude faster. In this paper we borrow from the concept of optics pump-probe measurement to for the first time study whether ionizing radiation can produce modulations of optical properties, which can be utilized as a novel method for radiation detection. We show that a refractive index modulation of approximately 5 × 10−6 is induced by interactions in a cadmium telluride (CdTe) crystal from a 511 keV photon source. Furthermore, using additional radionuclide sources, we show that the amplitude of the optical modulation signal varies linearly with both the detected event rate and average photon energy of the radiation source. PMID:27716640

  4. Evaluation of therapy response in breast and ovarian cancer patients by positron emission tomography (PET)

    Energy Technology Data Exchange (ETDEWEB)

    Baum, R. P.; Przetak, C. [Zentralklinik Bad Berka, Clinic of Nuclear Medicine, Center for PET, Bad Berka (Germany)

    2001-09-01

    Positron emission tomography (PET) has the potential to contribute significantly to treatment planning and to the evaluation of response to therapy in patients with cancer. For disease recurrence PET imaging provides information non-invasively. The final goal is to biologically characterize an individual patients' tumor and to predict the response to treatment at the earliest possible time. Quantitative and/or semi-quantitative PET studies yield valuable information in breast cancer regarding prognosis and response to chemohormontherapy in a timely fashion. In ovarian cancer, up to now only few studies have been performed applying PET techniques for the evaluation of treatment response. These preliminary studies indicate that serial assessment of tumor metabolism by FDG-PET early during effective chemotherapy may predict subsequent response to such therapy. PET studies can be repeated without any side-effects and with low radiation exposure and results can be directly correlated with clinical laboratory data and histology. Therapy monitoring by PET could help to optimize neoadjuvant therapy protocols and to avoid ineffective preoperative therapy in non-responders, but this has to be proven in a larger number of patients and in different neoadjuvant settings such as chemotherapy, radiation therapy, hormone therapy or a combination of these.

  5. Cerebral blood flow and glucose metabolism in hypothyroidism: a positron emission tomography study.

    Science.gov (United States)

    Constant, E L; de Volder, A G; Ivanoiu, A; Bol, A; Labar, D; Seghers, A; Cosnard, G; Melin, J; Daumerie, C

    2001-08-01

    Hypothyroidism is often associated with defective memory, psychomotor slowing, and depression. However, the relationship between thyroid status and cognitive or psychiatric disturbances remains unclear. Using psychometric scales, 10 patients who had undergone total thyroidectomy for thyroid carcinoma were evaluated for depression, anxiety, and psychomotor slowing; they were examined both when euthyroid and hypothyroid after thyroid hormone withdrawal. Positron emission tomography was used, with oxygen-15-labeled water and fluorine-18F-labeled 2-deoxy-2fluoro-D-glucose as the tracers, to correlate the regional cerebral blood flow and cerebral glucose metabolism with the mental state in patients. Two different image analysis techniques (regions of interest and statistical parametric maps) were applied. In hypothyroidism, there was a generalized decrease in regional cerebral blood flow (23.4%, P < 0.001) and in cerebral glucose metabolism (12.1%, P < 0.001) and there were no specific local defects. Patients were also significantly more depressed (P < 0.001), anxious (P < 0.001) and psychomotor slowed (P < 0.005) in hypo than in euthyroid status. These results indicate that the brain activity was globally reduced in severe hypothyroidism of short duration without the regional modifications usually observed in primary depression.

  6. FPGA-Based Front-End Electronics for Positron Emission Tomography.

    Science.gov (United States)

    Haselman, Michael; Dewitt, Don; McDougald, Wendy; Lewellen, Thomas K; Miyaoka, Robert; Hauck, Scott

    2009-02-22

    Modern Field Programmable Gate Arrays (FPGAs) are capable of performing complex discrete signal processing algorithms with clock rates above 100MHz. This combined with FPGA's low expense, ease of use, and selected dedicated hardware make them an ideal technology for a data acquisition system for positron emission tomography (PET) scanners. Our laboratory is producing a high-resolution, small-animal PET scanner that utilizes FPGAs as the core of the front-end electronics. For this next generation scanner, functions that are typically performed in dedicated circuits, or offline, are being migrated to the FPGA. This will not only simplify the electronics, but the features of modern FPGAs can be utilizes to add significant signal processing power to produce higher resolution images. In this paper two such processes, sub-clock rate pulse timing and event localization, will be discussed in detail. We show that timing performed in the FPGA can achieve a resolution that is suitable for small-animal scanners, and will outperform the analog version given a low enough sampling period for the ADC. We will also show that the position of events in the scanner can be determined in real time using a statistical positioning based algorithm.

  7. Novel Electro-Optical Coupling Technique for Magnetic Resonance-Compatible Positron Emission Tomography Detectors

    Directory of Open Access Journals (Sweden)

    Peter D. Olcott

    2009-03-01

    Full Text Available A new magnetic resonance imaging (MRI-compatible positron emission tomography (PET detector design is being developed that uses electro-optical coupling to bring the amplitude and arrival time information of high-speed PET detector scintillation pulses out of an MRI system. The electro-optical coupling technology consists of a magnetically insensitive photodetector output signal connected to a nonmagnetic vertical cavity surface emitting laser (VCSEL diode that is coupled to a multimode optical fiber. This scheme essentially acts as an optical wire with no influence on the MRI system. To test the feasibility of this approach, a lutetium-yttrium oxyorthosilicate crystal coupled to a single pixel of a solid-state photomultiplier array was placed in coincidence with a lutetium oxyorthosilicate crystal coupled to a fast photomultiplier tube with both the new nonmagnetic VCSEL coupling and the standard coaxial cable signal transmission scheme. No significant change was observed in 511 keV photopeak energy resolution and coincidence time resolution. This electro-optical coupling technology enables an MRI-compatible PET block detector to have a reduced electromagnetic footprint compared with the signal transmission schemes deployed in the current MRI/PET designs.

  8. Positron Emission Tomography Reveals Abnormal Topological Organization in Functional Brain Network in Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Qiu eXiangzhe

    2016-05-01

    Full Text Available Recent studies have demonstrated alterations in the topological organization of structural brain networks in diabetes mellitus (DM. However, the DM-related changes in the topological properties in functional brain networks are almost unexplored so far. We therefore used fluoro-D-glucose positron emission tomography (FDG-PET data to construct functional brain networks of 73 DM patients and 91 sex- and age-matched normal controls (NCs, followed by a graph theoretical analysis. We found that both DM patients and NCs had a small-world topology in functional brain network. In comparison to the NC group, the DM group was found to have significantly lower small-world index, lower normalized clustering coefficients and higher normalized shortest path length. Moreover, for diabetic patients, the nodal centrality was significantly reduced in the right rectus, the right cuneus, the left middle occipital gyrus, and the left postcentral gyrus, and it was significantly increased in the orbitofrontal region of the left middle frontal gyrus, the left olfactory region, and the right paracentral lobule. Our results demonstrated that the diabetic brain was associated with disrupted topological organization in the functional PET network, thus providing the functional evidence for the abnormalities of brain networks in DM.

  9. [The Quality Assurance (QA) and the Quality Control (QC) of Positron Emission Tomography (PET) Image].

    Science.gov (United States)

    Iimori, Takashi

    2015-01-01

    Positron emission tomography (PET) is widely used for image diagnostics; making judgments for early diagnostics, differential diagnostics, staging and treatment effect. As for undertaking the large clinical trial and the multicenter study using several diagnostics, the quantitative standardization of PET images is important. We should maintain the safety and the accuracy of daily clinical images. Moreover, we have to develop a safety treatment manual for instruments, apparatus and radiopharmaceuticals in order to produce PET studies of the highest diagnostic accuracy. In addition, daily quality assurance (QA) and quality control (QC) are very important in order to achieve efficiency and safety of PET studies. The importance of the QA and the QC have been recognized from the view of clinical incident protection points. PET will become more advanced in the future, and therefore the QA and the QC for PET images will continue to important in our work. In the view-risk management, we should reaffirm the importance of both QA and QC. Furthermore, we underline the importance of the constant management system and organization in order to gain the quality enhancement of PET imaging.

  10. Single photon emission computed tomography in the diagnosis of Alzheimer`s disease

    Energy Technology Data Exchange (ETDEWEB)

    Hanyu, Haruo; Asano, Tetsuichi; Abe, Shin`e; Arai, Hisayuki; Iwamoto, Toshihiko; Takasaki, Masaru; Shindo, Hiroaki; Abe, Kimihiko [Tokyo Medical Coll. (Japan)

    1997-06-01

    Studies with single photon emission computed tomography (SPECT) have shown temporoparietal (TP) hypoperfusion in patients with Alzheimer`s disease (AD). We evaluated the utility of this findings in the diagnosis of AD. SPECT images with {sup 123}I-iodoamphetamine were analyzed qualitatively by a rater without knowledge of the subject`s clinical status. Sixty-seven of 302 consecutive patients were judged as having TP hypoperfusion by SPECT imaging. This perfusion pattern was observed in 44 of 51 patients with AD, in 5 with mixed dementia, 8 with cerebrovascular disease (including 5 with dementia), 4 with Parkinson`s disease (including 2 with dementia), 1 with normal pressure hydrocephalus, 1 with slowly progressive aphasia, 1 with progressive autonomic failure, 2 with age-associated memory impairment, and 1 with unclassified dementia. The sensitivity for AD was 86.3% (44 of 51 AD), and the specificity was 91.2% (229 of 251 non-AD). Next, we looked for differences in perfusion images between patients with AD and without AD. Some patients without AD had additional hypoperfusion beyond TP areas: deep gray matter hypoperfusion and diffuse frontal hypoperfusion, which could be used to differentiate them from the patients with AD. Others could not be distinguished from patients with AD by their perfusion pattern. Although patients with other cerebral disorders occasionally have TP hypoperfusion, this finding makes the diagnosis of AD very likely. (author)

  11. Software development for dynamic position emission tomography: Dynamic image analysis (DIA) tool

    Energy Technology Data Exchange (ETDEWEB)

    Pyeon, Do Yeong; Jung, Young Jin [Dongseo University, Busan (Korea, Republic of); Kim, Jung Su [Dept. of Radilogical Science, Dongnam Health University, Suwon (Korea, Republic of)

    2016-09-15

    Positron Emission Tomography(PET) is nuclear medical tests which is a combination of several compounds with a radioactive isotope that can be injected into body to quantitatively measure the metabolic rate (in the body). Especially, Phenomena that increase (sing) glucose metabolism in cancer tissue using the 18F-FDG (Fluorodeoxyglucose) is utilized widely in cancer diagnosis. And then, Numerous studies have been reported that incidence seems high availability even in the modern diagnosis of dementia and Parkinson's (disease) in brain disease. When using a dynamic PET image including the time information in the static information that is provided for the diagnosis many can increase the accuracy of diagnosis. For this reason, clinical researchers getting great attention but, it is the lack of tools to conduct research. And, it interfered complex mathematical algorithm and programming skills for activation of research. In this study, in order to easy to use and enable research dPET, we developed the software based graphic user interface(GUI). In the future, by many clinical researcher using DIA-Tool is expected to be of great help to dPET research.

  12. Positron emission tomography imaging of tumor cell metabolism and application to therapy response monitoring

    Directory of Open Access Journals (Sweden)

    Amarnath eChallapalli

    2016-02-01

    Full Text Available Cancer cells do reprogramme their energy metabolism to enable several functions such as generation of biomass including membrane biosynthesis, and overcoming bioenergetic and redox stress. In this article we review both established and evolving radioprobes developed in association with positron emission tomography (PET to detect tumor cell metabolism and effect of treatment. Measurement of enhanced tumor cell glycolysis using 2-deoxy-2-[18F]-fluoro-D-glucose is well established in the clinic. Analogues of choline including [11C]-choline and various fluorinated derivatives are being tested in several cancer types clinically with PET. In addition to these, there is an evolving array of metabolic tracers for measuring intracellular transport of glutamine and other amino acids or for measuring glycogenesis, as well as probes used as surrogates for fatty acid synthesis or precursors for fatty acid oxidation. In addition to providing us with opportunities for examining the complex regulation of reprogrammed energy metabolism in living subjects, the PET methods open up opportunities for monitoring pharmacological activity of new therapies that directly or indirectly inhibit tumor cell metabolism.

  13. Identification of residual viable tissue in chronic ECG Q wave infarcts with positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Brunken, R.; Tillisch, J.; Schwaiger, M.; Child, J.; Marshall, R.; Phelps, M.; Schelbert, H.

    1985-05-01

    Although electrocardiographic Q waves have routinely been associated with transmural infarction, even small subendocardial infarctions may result in Q waves. The authors postulated that some chronic Q wave infarct regions might exhibit preserved metabolic activity on postron emission tomography (PET) with N-13 ammonia (NH3) and F-18 deoxyglucose (FDG). Twenty patients with 31 Q wave infarct regions (11 septal, 7 anterior, 3 lateral, and 10 inferoposterior) were studied. PET ischemia was defined as a discordant increase in FDG activity relative to NH3, while PET infarction was defined as a concordant reduction in both FDG and NH3 activity. The observed PET patterns were correlated with regional wall motion as assessed by independent observers on LV gram, 2D echo or radionuclide angiogram. There was a significant difference in wall motion score between regions that were normal on PET and those that were ischemic or infarcted on PET. No difference in wall motion was noted between regions with PET ischemia and PET infarction. Thus, PET reveals residual metabolic activity in a high proportion of Q wave infarct regions (68%) and analysis of wall motion does not allow differentiation between ischemic and infarcted regions.

  14. Speech disorders in olivopontocerebellar atrophy correlate with positron emission tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Kluin, K.J.; Gilman, S.; Markel, D.S.; Koeppe, R.A.; Rosenthal, G.; Junck, L.

    1988-06-01

    We compared the severity of ataxic and spastic dysarthria with local cerebral metabolic rates for glucose (lCMRGlc) in 30 patients with olivopontocerebellar atrophy (OPCA). Perceptual analysis was used to examine the speech disorders, and rating scales were devised to quantitate the degree of ataxia and spasticity in the speech of each patient. lCMRGlc was measured with /sup 18/F-2-fluoro-2-deoxy-D-glucose and positron emission tomography (PET). PET studies revealed marked hypometabolism in the cerebellar hemispheres, cerebellar vermis, and brainstem of OPCA patients compared with 30 control subjects. With data normalized to the cerebral cortex, a significant inverse correlation was found between the severity of ataxia in speech and the lCMRGlc within the cerebellar vermis, cerebellar hemispheres, and brainstem, but not within the thalamus. No significant correlation was found between the severity of spasticity in speech and lCMRGlc in any of these structures. The findings support the view that the severity of ataxia in speech in OPCA is related to the functional activity of the cerebellum and its connections in the brainstem.

  15. INSIDE in-beam positron emission tomography system for particle range monitoring in hadrontherapy.

    Science.gov (United States)

    Bisogni, Maria Giuseppina; Attili, Andrea; Battistoni, Giuseppe; Belcari, Nicola; Camarlinghi, Niccolo'; Cerello, Piergiorgio; Coli, Silvia; Del Guerra, Alberto; Ferrari, Alfredo; Ferrero, Veronica; Fiorina, Elisa; Giraudo, Giuseppe; Kostara, Eleftheria; Morrocchi, Matteo; Pennazio, Francesco; Peroni, Cristiana; Piliero, Maria Antonietta; Pirrone, Giovanni; Rivetti, Angelo; Rolo, Manuel D; Rosso, Valeria; Sala, Paola; Sportelli, Giancarlo; Wheadon, Richard

    2017-01-01

    The quality assurance of particle therapy treatment is a fundamental issue that can be addressed by developing reliable monitoring techniques and indicators of the treatment plan correctness. Among the available imaging techniques, positron emission tomography (PET) has long been investigated and then clinically applied to proton and carbon beams. In 2013, the Innovative Solutions for Dosimetry in Hadrontherapy (INSIDE) collaboration proposed an innovative bimodal imaging concept that combines an in-beam PET scanner with a tracking system for charged particle imaging. This paper presents the general architecture of the INSIDE project but focuses on the in-beam PET scanner that has been designed to reconstruct the particles range with millimetric resolution within a fraction of the dose delivered in a treatment of head and neck tumors. The in-beam PET scanner has been recently installed at the Italian National Center of Oncologic Hadrontherapy (CNAO) in Pavia, Italy, and the commissioning phase has just started. The results of the first beam test with clinical proton beams on phantoms clearly show the capability of the in-beam PET to operate during the irradiation delivery and to reconstruct on-line the beam-induced activity map. The accuracy in the activity distal fall-off determination is millimetric for therapeutic doses.

  16. The value of positron emission tomography in patients with non-small cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kee, Frank [Centre for Public Health, Queen' s University Belfast, Mulhouse Building, Royal Victoria Hospital Site, Grosvenor Road, Belfast BT12 6BJ, Northern Ireland (United Kingdom)], E-mail: f.kee@qub.ac.uk; Erridge, Sara [Edinburgh Cancer Centre, University of Edinburgh, Crewe Road South, Edinburgh EH4 2XU, Scotland (United Kingdom); Bradbury, Ian [Frontier Science (Scotland) Ltd., Grampian View, Kincraig, Inverness-shire PH21 1NA, Scotland (United Kingdom); Cairns, Karen [School of Maths and Physics, Queen' s University Belfast, David Bates Building, University Road, Belfast BT7 1NN, Northern Ireland (United Kingdom)

    2010-01-15

    Background: Pre-operative assessment of non-small cell lung cancer (NSCLC) is a major application of positron emission tomography (FDG-PET). Despite substantial evidence of diagnostic accuracy, relatively little attention has been paid to its effects on patient outcomes. This paper addresses this by extending an existing decision model to include patient-elicited utilities. Patients and methods: A decision-tree model of the effect of FDG-PET on pre-operative staging was converted to a Markov model. Utilities for futile and appropriate thoracotomy were elicited from 75 patients undergoing staging investigation for NSCLC. The decision model was then used to estimate the expected value of perfect information (EVPI) associated with three sources of uncertainty-the accuracy of PET, the accuracy of CT and the patient related utility of a futile thoracotomy. Results: The model confirmed the apparent cost-effectiveness of FDG-PET and indicated that the EVPI associated with the utility of futile thoracotomy considerably exceeds that associated with measures of accuracy. Conclusion: The study highlights the importance of patient related utilities in assessing the cost-effectiveness of diagnostic technologies. In the specific case of PET for pre-operative staging of NSCLC, future research effort should focus on such elicitation, rather than further refinement of accuracy estimates.

  17. Function of the shoulder muscles during arm elevation: an assessment using positron emission tomography.

    Science.gov (United States)

    Omi, Rei; Sano, Hirotaka; Ohnuma, Masahiro; Kishimoto, Koshi N; Watanuki, Shoichi; Tashiro, Manabu; Itoi, Eiji

    2010-05-01

    Although 2-deoxy-2-[(18)F]fluoro-D-glucose (FDG) positron emission tomography (PET) has been used for the assessment of skeletal muscle activities, its application to the shoulder muscles is only sparse. The purpose of this study was to investigate the activities of the shoulder muscles during arm elevation using PET. Six healthy volunteers performed an arm elevation exercise before and after FDG injection. The exercise consisted of 200 repetitions of arm elevation in the scapular plane with a 0.25-kg weight fixed to the wrist on both arms. PET examination was performed 50 min after FDG injection. For control data, PET scan was repeated for each subject on a separate day without any exercise. The volume of interest was established for each shoulder muscle. The subscapularis was divided into three portions (superior, middle, and inferior). The standardized uptake value (SUV) was calculated in each muscle to quantify its activity. The SUVs increased significantly after exercise in the deltoid, supraspinatus, and the superior portion of subscapularis. Among three divided portions of the subscapularis, the SUV of the superior one-third was significantly greater than the rest of the muscle after exercise. Our current study clearly indicated that there were two functionally different portions in the subscapularis muscle and the superior one-third played an important role during arm elevation in the scapular plane.

  18. Neural correlates of sensorimotor gating: A metabolic positron emission tomography study in awake rats

    Directory of Open Access Journals (Sweden)

    Cathrin eRohleder

    2014-05-01

    Full Text Available Impaired sensorimotor gating occurs in neuropsychiatric disorders such as schizophrenia and can be measured using the prepulse inhibition (PPI paradigm of the acoustic startle response. This assay is frequently used to validate animal models of neuropsychiatric disorders and to explore the therapeutic potential of new drugs. The underlying neural network of PPI has been extensively studied with invasive methods and genetic modifications. However, its relevance for healthy untreated animals and the functional interplay between startle- and PPI-related areas during a PPI session is so far unknown. Therefore, we studied awake rats in a PPI paradigm, startle control and background noise control, combined with behavioral [18F]fluoro-2-deoxyglucose positron emission tomography (FDG-PET. Subtractive analyses between conditions were used to identify brain regions involved in startle and PPI processing in well-hearing Black hooded rats. For correlative analysis with regard to the amount of PPI we also included hearing-impaired Lister hooded rats that startled more often, because their hearing threshold was just below the lowest prepulses. Metabolic imaging showed that the brain areas proposed for startle and PPI mediation are active during PPI paradigms in healthy untreated rats. More importantly, we show for the first time that the whole PPI modulation network is active during passive PPI sessions, where no selective attention to prepulse or startle stimulus is required. We conclude that this reflects ongoing monitoring of stimulus significance and constant adjustment of sensorimotor gating.

  19. Bone single photon emission computed tomography (SPECT in a patient with Pancoast tumor: a case report

    Directory of Open Access Journals (Sweden)

    Hamid Javadi

    Full Text Available CONTEXT: Non-small cell lung carcinomas (NSCLCs of the superior sulcus are considered to be the most challenging type of malignant thoracic disease. In this disease, neoplasms originating mostly from the extreme apex of the lung expand to the chest wall and thoracic inlet structures. Multiple imaging procedures have been applied to identify tumors and to stage and predict tumor resectability in surgical operations. Clinical examinations to localize pain complaints in shoulders and down the arms, and to screen for Horner's syndrome and abnormalities seen in paraclinical assessments, have been applied extensively for differential diagnosis of superior sulcus tumors. Although several types of imaging have been utilized for diagnosing and staging Pancoast tumors, there have been almost no reports on the efficiency of whole-body bone scans (WBBS for detecting the level of abnormality in cases of superior sulcus tumors. CASE REPORT: We describe a case of Pancoast tumor in which technetium-99m methylene diphosphonate (Tc-99m MDP bone single-photon emission-computed tomography (SPECT was able to accurately detect multiple areas of abnormality in the vertebrae and ribs. In describing this case, we stress the clinical and diagnostic points, in the hope of stimulating a higher degree of suspicion and thereby facilitating appropriate diagnosis and treatment. From the results of this study, further clinical trials to evaluate the potential of SPECT as an efficient imaging tool for the work-up on cases of Pancoast tumor are recommended.

  20. Modelling human drug abuse and addiction with dedicated small animal positron emission tomography.

    Science.gov (United States)

    Dalley, Jeffrey W; Fryer, Tim D; Aigbirhio, Franklin I; Brichard, Laurent; Richards, Hugh K; Hong, Young T; Baron, Jean-Claude; Everitt, Barry J; Robbins, Trevor W

    2009-01-01

    Drug addiction is a chronically relapsing brain disorder, which causes substantial harm to the addicted individual and society as a whole. Despite considerable research we still do not understand why some people appear particularly disposed to drug abuse and addiction, nor do we understand how frequently co-morbid brain disorders such as depression and attention-deficit hyperactivity disorder (ADHD) contribute causally to the emergence of addiction-like behaviour. In recent years positron emission tomography (PET) has come of age as a translational neuroimaging technique in the study of drug addiction, ADHD and other psychopathological states in humans. PET provides unparalleled quantitative assessment of the spatial distribution of radiolabelled molecules in the brain and because it is non-invasive permits longitudinal assessment of physiological parameters such as binding potential in the same subject over extended periods of time. However, whilst there are a burgeoning number of human PET experiments in ADHD and drug addiction there is presently a paucity of PET imaging studies in animals despite enormous advances in our understanding of the neurobiology of these disorders based on sophisticated animal models. This article highlights recent examples of successful cross-species convergence of findings from PET studies in the context of drug addiction and ADHD and identifies how small animal PET can more effectively be used to model complex psychiatric disorders involving at their core impaired behavioural self-control.

  1. Energy discrimination for positron emission tomography using the time information of the first detected photons

    Science.gov (United States)

    Therrien, A. C.; Lemaire, W.; Lecoq, P.; Fontaine, R.; Pratte, J.-F.

    2018-01-01

    The advantages of Time-of-Flight positron emission tomography (TOF-PET) have pushed the development of detectors with better time resolution. In particular, Silicon Photomultipliers (SiPM) have evolved tremendously in the past decade and arrays with a fully digital readout are the next logical step (dSiPM). New multi-timestamp methods use the precise time information of multiple photons to estimate the time of a PET event with greater accuracy, resulting in excellent time resolution. We propose a method which uses the same timestamps as the time estimator to perform energy discrimination, thus using data obtained within 5 ns of the beginning of the event. Having collected all the necessary information, the dSiPM could then be disabled for the remaining scintillation while dedicated electronics process the collected data. This would reduce afterpulsing as the SPAD would be turned off for several hundred nanoseconds, emptying the majority of traps. The proposed method uses a strategy based on subtraction and minimal electronics to reject energy below a selected threshold. This method achieves an error rate of less than 3% for photopeak discrimination (threshold at 400 keV) for dark count rates up to 100 cps/μm2, time-to-digital converter resolution up to 50 ps and a photon detection efficiency ranging from 10 to 70%.

  2. The sensitivity of 18-fluorodopa positron emission tomography and magnetic resonance imaging in Parkinson's disease.

    Science.gov (United States)

    Heiss, W-D; Hilker, R

    2004-01-01

    Parkinson's disease (PD) as the most important movement disorder is characterized by a progressive loss of nigral dopamine neurons and a subsequent degeneration within several other transmitter systems. Functional brain imaging with positron emission tomography (PET) and the radiotracer 18-fluorodopa (FDOPA) is capable to quantify the deficiency of dopamine synthesis and storage within pre-synaptic striatal nerve terminals. Therefore, FDOPA-PET allows the diagnosis of PD in early disease stages and the differentiation of clinically unclear cases from other movement disorders, e.g. essential tremor. Additionally, FDOPA-PET imaging permits the follow-up of disease progression, the assessment of medical and surgical PD therapy strategies with possible neuroprotective properties and the detection of pre-clinical disease in subjects at risk for the disorder. The classical domain of morphological magnetic resonance imaging (MRI) is the differentiation of symptomatic Parkinsonism from PD. However, recent advances in MRI data acquisition and analysis techniques demonstrated MRI to be also a valuable tool for detection of nigral pathology in PD and for differentiation of neurodegenerative disorders with atypical Parkinsonism.

  3. Novel electro-optical coupling technique for magnetic resonance-compatible positron emission tomography detectors.

    Science.gov (United States)

    Olcott, Peter D; Peng, Hao; Levin, Craig S

    2009-01-01

    A new magnetic resonance imaging (MRI)-compatible positron emission tomography (PET) detector design is being developed that uses electro-optical coupling to bring the amplitude and arrival time information of high-speed PET detector scintillation pulses out of an MRI system. The electro-optical coupling technology consists of a magnetically insensitive photodetector output signal connected to a nonmagnetic vertical cavity surface emitting laser (VCSEL) diode that is coupled to a multimode optical fiber. This scheme essentially acts as an optical wire with no influence on the MRI system. To test the feasibility of this approach, a lutetium-yttrium oxyorthosilicate crystal coupled to a single pixel of a solid-state photomultiplier array was placed in coincidence with a lutetium oxyorthosilicate crystal coupled to a fast photomultiplier tube with both the new nonmagnetic VCSEL coupling and the standard coaxial cable signal transmission scheme. No significant change was observed in 511 keV photopeak energy resolution and coincidence time resolution. This electro-optical coupling technology enables an MRI-compatible PET block detector to have a reduced electromagnetic footprint compared with the signal transmission schemes deployed in the current MRI/PET designs.

  4. Altered myocardial substrate metabolism is associated with myocardial dysfunction in early diabetic cardiomyopathy in rats: studies using positron emission tomography

    OpenAIRE

    Lammertsma Adriaan A; Molthoff Carla FM; Lubberink Mark; Duijst Suzanne; Boontje Nicky M; Vlasblom Ronald; Huisman Marc C; van den Brom Charissa E; van der Velden Jolanda; Boer Christa; Ouwens D Margriet; Diamant Michaela

    2009-01-01

    Abstract Background In vitro data suggest that changes in myocardial substrate metabolism may contribute to impaired myocardial function in diabetic cardiomyopathy (DCM). The purpose of the present study was to study in a rat model of early DCM, in vivo changes in myocardial substrate metabolism and their association with myocardial function. Methods Zucker diabetic fatty (ZDF) and Zucker lean (ZL) rats underwent echocardiography followed by [11C]palmitate positron emission tomography (PET) u...

  5. [Analysis of single-photon emission computed tomography in patients with hypertensive encephalopathy complicated with previous hypertensive crisis].

    Science.gov (United States)

    Kustkova, H S

    2012-01-01

    In cerebrovascular diseases pefuzionnaya single photon emission computed tomography with lipophilic amines used for the diagnosis of functional disorders of cerebral blood flow. Quantitative calculations helps clarify the nature of vascular disease and clarify the adequacy and effectiveness of the treatment. In this modern program for SPECT ensure conduct not only as to the calculation of blood flow, but also make it possible to compute also the absolute values of cerebral blood flow.

  6. Measuring brain synaptic vesicle protein 2A with positron emission tomography and [18F]UCB-H

    OpenAIRE

    Bahri, Mohamed Ali; Plenevaux, Alain; Aerts, Joël; Bastin, Christine; Becker, Guillaume; Mercier, Joël; Valade, Anne; Buchanan, Tim; Mestdagh, Nathalie; Ledoux, Didier; Seret, Alain; Luxen, André; Salmon, Eric

    2017-01-01

    Introduction: Brain distribution of synaptic vesicle protein 2Awas measured with fluorine-18 UCBH ([18F]UCB-H) and positron emission tomography (PET). Methods: Images of synaptic density were acquired in healthy volunteers (two young participants and two seniors). Input function was measured by arterial blood sampling (arterial input function) and derived from PET images using carotid activity (image-derived input function). Logan graphical analysis was used to estimate regional synaptic v...

  7. Decrease of prefrontal metabolism after subthalamic stimulation in obsessive-compulsive disorder: a positron emission tomography study.

    OpenAIRE

    Le Jeune, Florence; Vérin, Marc; N'Diaye, Karim; Drapier, Dominique; Leray, Emmanuelle; Du Montcel, Sophie Tezenas; Baup, Nicolas; Pelissolo, Antoine; Polosan, Mircea; Mallet, Luc; Yelnik, Jérome; Devaux, Bertrand; Fontaine, Denys; Chereau, Isabelle; Bourguignon, Aurélie

    2010-01-01

    International audience; BACKGROUND: High-frequency bilateral subthalamic nucleus (STN) deep brain stimulation (DBS) is a promising treatment in refractory obsessive-compulsive disorder (OCD). METHOD: Using the crossover, randomized, and double-blind procedure adopted by the STOC study, 10 patients treated with high-frequency bilateral STN DBS underwent am 18-fluorodeoxyglucose positron emission tomography (PET) investigation to highlight the neural substratum of this therapeutic approach. RES...

  8. 3D fast reconstruction in positron emission tomography; Reconstrucao 3D rapida em tomografia por emissao de positrons

    Energy Technology Data Exchange (ETDEWEB)

    Egger, M.L. [Sao Paulo Univ., SP (Brazil). Instituto do Coracao. Div. de Informatica; Scheurer, A. Hermann; Joseph, C. [Lausanne Univ. (Switzerland). Inst. de Physique Nucleaire; Morel, C. [Geneva Univ. (Switzerland). Hospital. Div. of Nuclear Medicine

    1996-12-31

    The issue of long reconstruction times in positron emission tomography (PET) has been addressed from several points of view, resulting in an affordable dedicated system capable of handling routine 3D reconstructions in a few minutes per frame : on the hardware side using fast processors and a parallel architecture, and on the software side, using efficient implementation of computationally less intensive algorithms 6 refs., 2 figs., 1 tab.

  9. Diagnostic advantage of stress computed tomography myocardial perfusion over single-photon emission computed tomography for the assessment of myocardial ischemia.

    Science.gov (United States)

    Ueki, Yasushi; Izawa, Atsushi; Kashiwagi, Daisuke; Nishiyama, Shigeki; Aso, Shinichi; Suzuki, Chihiro; Sakurai, Shumpei; Oguchi, Kazuhiro; Yazaki, Yoshikazu; Ikeda, Uichi; Kuwahara, Koichiro

    2017-08-01

    This study compared adenosine stress computed tomography myocardial perfusion (CTP) with single-photon emission computed tomography (SPECT) in the diagnosis of functionally significant coronary artery stenosis using fractional flow reserve (FFR) as reference standard. We included a total of 93 coronary arteries from 31 patients in whom at least one vessel with ≥50% stenosis was detected with computed tomography coronary angiography. All patients underwent both SPECT and adenosine stress CTP, followed by invasive coronary angiography (ICA) and FFR. Diagnostic accuracy between CTP and SPECT was compared according to positive findings of either ≥99% stenosis on ICA or FFR ≤0.8. Among 78 vessels eligible for the quantitative analyses, significant coronary artery disease (CAD) was diagnosed in 22 vessels of 19 patients. Comparison of CTP vs. SPECT for sensitivity, specificity, positive predictive value (PPV), negative predictive value, and accuracy in detecting significant CAD were 59% vs. 18%, 96% vs. 93%, 87% vs. 50%, 86% vs. 74%, and 86% vs. 72%, respectively. CTP demonstrated a significant diagnostic advantage over SPECT in the identification of significant CAD, especially in terms of sensitivity and PPV. Adenosine stress CTP is useful for the noninvasive diagnosis of functionally significant CAD. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  10. Carbon-11-Pittsburgh compound B positron emission tomography imaging of amyloid deposition in presenilin 1 mutation carriers.

    Science.gov (United States)

    Knight, William D; Okello, Aren A; Ryan, Natalie S; Turkheimer, Federico E; Rodríguez Martinez de Llano, Sofia; Edison, Paul; Douglas, Jane; Fox, Nick C; Brooks, David J; Rossor, Martin N

    2011-01-01

    (11)Carbon-Pittsburgh compound B positron emission tomography studies have suggested early and prominent amyloid deposition in the striatum in presenilin 1 mutation carriers. This cross-sectional study examines the (11)Carbon-Pittsburgh compound B positron emission tomography imaging profiles of presymptomatic and mildly affected (mini-mental state examination ≥ 20) carriers of seven presenilin 1 mutations, comparing them with groups of controls and symptomatic sporadic Alzheimer's disease cases. Parametric ratio images representing (11)Carbon-Pittsburgh compound B retention from 60 to 90 min were created using the pons as a reference region and nine regions of interest were studied. We confirmed that increased amyloid load may be detected in presymptomatic presenilin 1 mutation carriers with (11)Carbon-Pittsburgh compound B positron emission tomography and that the pattern of retention is heterogeneous. Comparison of presenilin 1 and sporadic Alzheimer's disease groups revealed significantly greater thalamic retention in the presenilin 1 group and significantly greater frontotemporal retention in the sporadic Alzheimer's disease group. A few individuals with presenilin 1 mutations showed increased cerebellar (11)Carbon-Pittsburgh compound B retention suggesting that this region may not be as suitable a reference region in familial Alzheimer's disease.

  11. Architecture of a Dual-Modality, High-Resolution, Fully Digital Positron Emission Tomography/Computed Tomography (PET/CT) Scanner for Small Animal Imaging

    Science.gov (United States)

    Fontaine, R.; Belanger, F.; Cadorette, J.; Leroux, J.-D.; Martin, J.-P.; Michaud, J.-B.; Pratte, J.-F.; Robert, S.; Lecomte, R.

    2005-06-01

    Contemporary positron emission tomography (PET) scanners are commonly implemented with very large scale integration analog front-end electronics to reduce power consumption, space, noise, and cost. Analog processing yields excellent results in dedicated applications, but offers little flexibility for sophisticated signal processing or for more accurate measurements with newer, fast scintillation crystals. Design goals of the new Sherbrooke PET/computed tomography (CT) scanner are: 1) to achieve 1 mm resolution in both emission (PET) and transmission (CT) imaging using the same detector channels; 2) to be able to count and discriminate individual X-ray photons in CT mode. These requirements can be better met by sampling the analog signal from each individual detector channel as early as possible, using off-the-shelf, 8-b, 100-MHz, high-speed analog-to-digital converters (ADC) and digital processing in field programmable gate arrays (FPGAs). The core of the processing units consists of Xilinx SpartanIIe that can hold up to 16 individual channels. The initial architecture is designed for 1024 channels, but modularity allows extending the system up to 10 K channels or more. This parallel architecture supports count rates in excess of a million hits/s/scintillator in CT mode and up to 100 K events/s/scintillator in PET mode, with a coincidence time window of less than 10 ns full-width at half-maximum.

  12. Redistribution of myocardial perfusion during permanent dual chamber pacing in symptomatic non-obstructive hypertrophic cardiomyopathy : A quantitative positron emission tomography study

    NARCIS (Netherlands)

    Posma, JL; Blanksma, PK; vanderWall, EE

    Dual chamber pacing causes significant symptomatic improvement in many patients with hypertrophic cardiomyopathy. The mechanism behind this beneficial response is not fully understood. Positron emission tomography showed a redistribution of myocardial flow during pacing in a patient with

  13. Quantification of myocardial perfusion using cardiac magnetic resonance imaging correlates significantly to rubidium-82 positron emission tomography in patients with severe coronary artery disease

    DEFF Research Database (Denmark)

    Qayyum, Abbas A; Hasbak, Philip; Larsson, Henrik B W

    2014-01-01

    INTRODUCTION: Aim was to compare absolute myocardial perfusion using cardiac magnetic resonance imaging (CMRI) based on Tikhonov's procedure of deconvolution and rubidium-82 positron emission tomography (Rb-82 PET). MATERIALS AND METHODS: Fourteen patients with coronary artery stenosis underwent ...

  14. Hybrid Magnetic Resonance Imaging and Positron Emission Tomography With Fluorodeoxyglucose to Diagnose Active Cardiac Sarcoidosis.

    Science.gov (United States)

    Dweck, Marc R; Abgral, Ronan; Trivieri, Maria Giovanna; Robson, Philip M; Karakatsanis, Nicolas; Mani, Venkatesh; Palmisano, Anna; Miller, Marc A; Lala, Anuradha; Chang, Helena L; Sanz, Javier; Contreras, Johanna; Narula, Jagat; Fuster, Valentin; Padilla, Maria; Fayad, Zahi A; Kovacic, Jason C

    2017-06-09

    The purpose of this study was to explore the diagnostic usefulness of hybrid cardiac magnetic resonance (CMR) and positron emission tomography (PET) using 18F-fluorodeoxyglucose (FDG) for active cardiac sarcoidosis. Active cardiac sarcoidosis (aCS) is underdiagnosed and has a high mortality. Patients with clinical suspicion of aCS underwent hybrid CMR/PET with late gadolinium enhancement (LGE) and FDG to assess the pattern of injury and disease activity, respectively. Patients were categorized visually as magnetic resonance (MR)+PET+ (characteristic LGE aligning exactly with increased FDG uptake), MR+PET- (characteristic LGE but no increased FDG), MR-PET- (neither characteristic LGE nor increased FDG), and MR-PET+ (increased FDG uptake in absence of characteristic LGE) and further characterized as aCS+ (MR+PET+) or aCS- (MR+PET-, MR-PET-, MR-PET+). FDG uptake was quantified using maximum target-to-normal-myocardium ratio and the net uptake rate (Ki) from dynamic Patlak analysis. Receiver operating characteristic methods were used to identify imaging biomarkers for aCS. FDG PET was assessed using computed tomography/PET in 19 control subjects with healthy myocardium. A total of 25 patients (12 males; 54.9 ± 9.8 years of age) were recruited prospectively; 8 were MR+PET+, suggestive of aCS; 1 was MR+PET-, consistent with inactive cardiac sarcoidosis; and 8 were MR-PET-, with no imaging evidence of cardiac sarcoidosis. Eight patients were MR-PET+ (6 with global myocardial FDG uptake, 2 with focal-on-diffuse uptake); they demonstrated distinct Ki values and hyperintense maximum standardized uptake value compared with MR+PET+ patients. Similar hyperintense patterns of global (n = 9) and focal-on-diffuse (n = 2) FDG uptake were also observed in control patients, suggesting physiological myocardial uptake. Maximum target-to-normal-myocardium ratio values were higher in the aCS+ group (p < 0.001), demonstrating an area under the curve of 0.98 on receiver operating

  15. In vivo imaging of schistosomes to assess disease burden using positron emission tomography (PET.

    Directory of Open Access Journals (Sweden)

    Nicolas Salem

    2010-09-01

    Full Text Available Schistosomes are chronic intravascular helminth parasites of humans causing a heavy burden of disease worldwide. Diagnosis of schistosomiasis currently requires the detection of schistosome eggs in the feces and urine of infected individuals. This method unreliably measures disease burden due to poor sensitivity and wide variances in egg shedding. In vivo imaging of schistosome parasites could potentially better assess disease burden, improve management of schistosomiasis, facilitate vaccine development, and enhance study of the parasite's biology. Schistosoma mansoni (S. mansoni have a high metabolic demand for glucose. In this work we investigated whether the parasite burden in mice could be assessed by positron emission tomography (PET imaging with 2-deoxy-2[(18F]fluoro-D-glucose (FDG.Live adult S. mansoni worms FDG uptake in vitro increased with the number of worms. Athymic nude mice infected with S. mansoni 5-6 weeks earlier were used in the imaging studies. Fluorescence molecular tomography (FMT imaging with Prosense 680 was first performed. Accumulation of the imaging probe in the lower abdomen correlated with the number of worms in mice with low infection burden. The total FDG uptake in the common portal vein and/or regions of elevated FDG uptake in the liver linearly correlated to the number of worms recovered from infected animals (R(2 =0.58, P<0.001, n = 40. FDG uptake showed a stronger correlation with the worm burden in mice with more than 50 worms (R(2 = 0.85, P<0.001, n = 17. Cryomicrotome imaging confirmed that most of the worms in a mouse with a high infection burden were in the portal vein, but not in a mouse with a low infection burden. FDG uptake in recovered worms measured by well counting closely correlated with worm number (R(2 = 0.85, P<0.001, n = 21. Infected mice showed a 32% average decrease in total FDG uptake after three days of praziquantel treatment (P = 0.12. The total FDG uptake in untreated mice increased

  16. Pulmonary Arterial Hypertension With Abnormal V/Q Single-Photon Emission Computed Tomography.

    Science.gov (United States)

    Chan, Kenneth; Ioannidis, Stefanos; Coghlan, John G; Hall, Margaret; Schreiber, Benjamin E

    2017-10-16

    This study aimed to evaluate the incidence and clinical outcomes of abnormal ventilation/perfusion (V/Q) single-photon emission computed tomography (SPECT) without thromboembolism, especially in patients with group I pulmonary arterial hypertension (PAH). American Heart Association/American College of Cardiology and European Society of Cardiology guidelines recommend V/Q scan for screening for chronic thromboembolic pulmonary hypertension. The significance of patients with abnormal V/Q SPECT findings but no thromboembolism demonstrated in further investigations remained unclear. A distinct pattern of global patchy changes not typical of thromboembolism is recognized, but guidelines for reporting these in the context of PAH are lacking. A total of 136 patients who underwent V/Q SPECT and right-sided heart catheterization showing mean pulmonary arterial pressure ≥25 mm Hg were included. V/Q SPECT findings were reported using European Association of Nuclear Medicine criteria for pulmonary embolism followed by computed tomography pulmonary angiography screening for positive thromboembolism and further invasive pulmonary angiography for distal thromboembolism. The abnormal V/Q SPECT images were further analyzed according to perfusion pattern into focal or global perfusion defects. V/Q SPECT showed thromboembolic disease in 44 patients, but 19 of these patients had no thromboembolism demonstrated by pulmonary angiography. Among these patients, 15 of 19 (78.9%) had group I PAH, and the majority had diffuse, patchy perfusion defects. After redefining V/Q SPECT images according to the perfusion pattern, those patients with global perfusion defects had higher mean pulmonary arterial pressure compared with patients with focal perfusion defects and normal scans (mean difference +13.9 and +6.2 mm Hg, respectively; p = 0.0002), as well as higher pulmonary vascular resistance (mean difference +316.6 and +226.3 absolute resistance units, respectively; p = 0

  17. Multitracer study with positron emission tomography in Creutzfeldt-Jakob disease

    Energy Technology Data Exchange (ETDEWEB)

    Engler, Henry [Uppsala University PET Centre, Uppsala University Hospital, SE 751 85 Uppsala (Sweden); Department of Neurology, Uppsala University Hospital, Uppsala (Sweden); Lundberg, Per Olov [Department of Neurology, Uppsala University Hospital, Uppsala (Sweden); Ekbom, Karl [Department of Neurology, Huddinge University Hospital, Stockholm (Sweden); Nennesmo, Inger [Department of Pathology, Huddinge University Hospital, Stockholm (Sweden); Nilsson, Anna; Bergstroem, Mats; Hartvig, Per; Laangstroem, Bengt [Uppsala University PET Centre, Uppsala University Hospital, SE 751 85 Uppsala (Sweden); Tsukada, Hideo [Hamamatsu Photonics K.K.Central Research Lab, Hamakita City (Japan)

    2003-01-01

    During the period February 1997 to April 2000, 15 patients with clinical symptoms of Creutzfeldt-Jakob disease (CJD) were referred to Uppsala University PET Centre. Positron emission tomography (PET) was performed to detect characteristic signs of the disease, e.g. neuronal death and/or astrocytosis in the brain. The examinations were performed in one session starting with oxygen-15 labelled water scan to measure regional cerebral blood flow, followed by imaging with the monoamine oxidase B inhibitor N-[{sup 11}C-methyl]-L-deuterodeprenyl (DED) to assess astrocytosis in the brain and finally imaging with fluorine-18 2-fluorodeoxyglucose (FDG) to assess regional cerebral glucose metabolism (rCMR{sub glu}). Nine of the patients fulfilled the clinical criteria of probable CJD. In eight of them, FDG and DED imaging revealed, in comparison with normal controls, a typical pattern characterized by a pronounced regional decrease (<2SD) in glucose brain metabolism, indicative of neuronal dysfunction; this was accompanied by a similar increase (>2SD) in DED binding, indicating astrocytosis. These changes were most pronounced in the cerebellum and the frontal, occipital and parietal cortices, whereas the pons, the thalamus and the putamen were less affected and the temporal cortex appeared unaffected. The cerebral blood flow showed a pattern similar to that observed with FDG. In the ninth patient, analysis with DED was not possible. The diagnosis of definite CJD according to international consensus criteria was confirmed in six of these patients. In one patient with probable CJD, protease-resistant prion protein (PrPres) could not be demonstrated. In two patients with probable CJD, autopsy was not allowed. Computed tomography and magnetic resonance imaging, performed in four and seven of these nine patients respectively, showed unspecific, mainly atrophic changes. In six other patients, the PET examinations gave a different pattern. In three of them, high rCMR{sub glu} was

  18. Uses and limitations of FDG positron emission tomography in patients with head and neck cancer.

    Science.gov (United States)

    Hanasono, M M; Kunda, L D; Segall, G M; Ku, G H; Terris, D J

    1999-06-01

    Numerous authors have reported the potential usefulness of positron emission tomography (PET). These studies have had conflicting results, at least partly owing to limited sample sizes. The objective of this study is to define not only the uses, but also the limitations of PET in patients with head and neck cancer. Nonrandomized, retrospective analysis of PET at an academic institution. The authors performed 146 PET scans on 133 patients with head and neck cancer. Eighteen patients (19 PET scans) with thyroid disorders were excluded. A minimum 1 year of follow-up was available in 84 patients, who were separated into groups based on whether the PET was used to detect unknown primary cancers (n = 20), stage neck nodal and distant metastases (n = 8), monitor response to nonsurgical therapy (n = 22), or detect recurrent or residual cancers (n = 34). The results of PET were compared with results from computed tomography (CT) and magnetic resonance imaging (MRI) performed in the same patients. Of the unknown primary cancers, PET correctly identified 7 of 20 primary sites, giving a sensitivity of 35%. When combined with CT or MRI, the sensitivity increased to 40%. When used for detection of metastatic disease, PET demonstrated five of five nodal metastases (100%) and two of four distant metastases (50%). In evaluating the response to nonsurgical therapy, PET had a sensitivity of 50% and a specificity of 83% for detecting tumor at the primary site and a sensitivity of 86% and a specificity of 73% for detecting nodal disease. When used for evaluation of recurrent/residual disease, PET identified seven of seven cases of local recurrences/residual disease and had a specificity of 85%. PET also detected seven of seven cases of nodal disease and had a specificity of 89%. For staging purposes, PET is limited by its lack of anatomic detail. However, PET compares favorably with CT and MRI in detecting recurrent/residual cancers. PET imaging complements the more traditional imaging

  19. Ventilation/Perfusion Positron Emission Tomography--Based Assessment of Radiation Injury to Lung.

    Science.gov (United States)

    Siva, Shankar; Hardcastle, Nicholas; Kron, Tomas; Bressel, Mathias; Callahan, Jason; MacManus, Michael P; Shaw, Mark; Plumridge, Nikki; Hicks, Rodney J; Steinfort, Daniel; Ball, David L; Hofman, Michael S

    2015-10-01

    To investigate (68)Ga-ventilation/perfusion (V/Q) positron emission tomography (PET)/computed tomography (CT) as a novel imaging modality for assessment of perfusion, ventilation, and lung density changes in the context of radiation therapy (RT). In a prospective clinical trial, 20 patients underwent 4-dimensional (4D)-V/Q PET/CT before, midway through, and 3 months after definitive lung RT. Eligible patients were prescribed 60 Gy in 30 fractions with or without concurrent chemotherapy. Functional images were registered to the RT planning 4D-CT, and isodose volumes were averaged into 10-Gy bins. Within each dose bin, relative loss in standardized uptake value (SUV) was recorded for ventilation and perfusion, and loss in air-filled fraction was recorded to assess RT-induced lung fibrosis. A dose-effect relationship was described using both linear and 2-parameter logistic fit models, and goodness of fit was assessed with Akaike Information Criterion (AIC). A total of 179 imaging datasets were available for analysis (1 scan was unrecoverable). An almost perfectly linear negative dose-response relationship was observed for perfusion and air-filled fraction (r(2)=0.99, Pfit as evaluated by AIC. Perfusion, ventilation, and the air-filled fraction decreased 0.75 ± 0.03%, 0.71 ± 0.06%, and 0.49 ± 0.02%/Gy, respectively. Within high-dose regions, higher baseline perfusion SUV was associated with greater rate of loss. At 50 Gy and 60 Gy, the rate of loss was 1.35% (P=.07) and 1.73% (P=.05) per SUV, respectively. Of 8/20 patients with peritumoral reperfusion/reventilation during treatment, 7/8 did not sustain this effect after treatment. Radiation-induced regional lung functional deficits occur in a dose-dependent manner and can be estimated by simple linear models with 4D-V/Q PET/CT imaging. These findings may inform future studies of functional lung avoidance using V/Q PET/CT. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  20. Spatiotemporal Stability of Cu-ATSM and FLT Positron Emission Tomography Distributions During Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Bradshaw, Tyler J.; Yip, Stephen; Jallow, Ngoneh [Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin, Madison, Wisconsin (United States); Forrest, Lisa J. [Department of Surgical Sciences, School of Veterinary Medicine, University of Wisconsin, Madison, Wisconsin (United States); Jeraj, Robert, E-mail: rjeraj@wisc.edu [Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin, Madison, Wisconsin (United States); Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin, Madison, Wisconsin (United States)

    2014-06-01

    Purpose: In dose painting, in which functional imaging is used to define biological targets for radiation therapy dose escalation, changes in spatial distributions of biological properties during treatment can compromise the quality of therapy. The goal of this study was to assess the spatiotemporal stability of 2 potential dose painting targets—hypoxia and proliferation—in canine tumors during radiation therapy. Methods and Materials: Twenty-two canine patients with sinonasal tumors (14 carcinoma and 8 sarcoma) were imaged before hypofractionated radiation therapy with copper(II)-diacetyl-bis(N4-methylthiosemicarbazone) (Cu-ATSM) positron emission tomography/computed tomography (PET/CT) for hypoxia and 3′-deoxy-3′-{sup 18}F-fluorothymidine (FLT) PET/CT for proliferation. The FLT scans were repeated after 2 fractions and the Cu-ATSM scans after 3 fractions. Midtreatment PET/CT images were deformably registered to pretreatment PET/CT images. Voxel-based Spearman correlation coefficients quantified the spatial stability of Cu-ATSM and FLT uptake distributions between pretreatment and midtreatment scans. Paired t tests determined significant differences between the patients' respective Cu-ATSM and FLT correlations coefficients. Standardized uptake value measures were also compared between pretreatment and midtreatment scans by use of paired t tests. Results: Spatial distributions of Cu-ATSM and FLT uptake were stable through midtreatment for both sarcomas and carcinomas: the population mean ± standard deviation in Spearman correlation coefficient was 0.88 ± 0.07 for Cu-ATSM and 0.79 ± 0.13 for FLT. The patients' Cu-ATSM correlation coefficients were significantly higher than their respective FLT correlation coefficients (P=.001). Changes in Cu-ATSM SUV measures from pretreatment to midtreatment were histology dependent: carcinomas experienced significant decreases in Cu-ATSM uptake (P<.05), whereas sarcomas did not (P>.20). Both histologies

  1. In vivo imaging of therapy response to a novel Pan-HER antibody mixture using FDG and FLT positron emission tomography

    DEFF Research Database (Denmark)

    Nielsen, Carsten H; Jensen, Mette M; Kristensen, Lotte K

    2015-01-01

    against either EGFR (HER1), HER2, HER3 or all three receptors combined by Pan-HER. Small animal positron emission tomography/computed tomography (PET/CT) with 2'-deoxy-2'-[18F]fluoro-D-glucose (FDG) and 3'-deoxy-3'-[18F]fluorothymidine (FLT) was performed at baseline and at day 1 or 2 after initiation...

  2. Neurofibroma of the breast detected on position emission tomography-CT in a patient with neurofibromatosis type 1: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ho Seok; Kim, Hye Jung; Yang, Bang; Lee So Mi; Jeong, Ji Yun [Kyungpook National University Hospital, Daegu(Korea, Republic of)

    2016-02-15

    Neurofibromas of the breast are rare. They are commonly found as solitary lesions or parts of neurofibromatosis type 1 and are usually located on the nipple-areolar area. We describe a case of neurofibroma of the breast in the retromammary space, which was detected on positron emission tomography-computed tomography after hysterectomy due to endometrial cancer.

  3. Synthesis and characterization of EADAM: a selective radioligand for mapping the brain serotonin transporters by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Jarkas, Nachwa [Department of Radiology, Division of Radiological Sciences, Emory University, Atlanta, GA 30322 (United States); McConathy, Jonathan [Department of Radiology, Division of Radiological Sciences, Emory University, Atlanta, GA 30322 (United States); Department of Psychiatry and Behavior Sciences, Emory University, Atlanta, GA 30322 (United States); Votaw, John R. [Department of Radiology, Division of Radiological Sciences, Emory University, Atlanta, GA 30322 (United States); Voll, Ronald J. [Department of Radiology, Division of Radiological Sciences, Emory University, Atlanta, GA 30322 (United States); Malveaux, Eugene [Department of Radiology, Division of Radiological Sciences, Emory University, Atlanta, GA 30322 (United States); Camp, Vernon M. [Department of Radiology, Division of Radiological Sciences, Emory University, Atlanta, GA 30322 (United States); Williams, Larry [Department of Radiology, Division of Radiological Sciences, Emory University, Atlanta, GA 30322 (United States); Goodman, Robin R. [Department of Radiology, Division of Radiological Sciences, Emory University, Atlanta, GA 30322 (United States); Kilts, Clinton D. [Department of Psychiatry and Behavior Sciences, Emory University, Atlanta, GA 30322 (United States); Goodman, Mark M. [Department of Radiology, Division of Radiological Sciences, Emory University, Atlanta, GA 30322 (United States) and Department of Psychiatry and Behavior Sciences, Emory University, Atlanta, GA 30322 (United States)]. E-mail: mgoodma@emory.edu

    2005-01-01

    [{sup 11}C]N,N-Dimethyl-2-(2'-amino-4'-ethylphenylthio)benzylamine ([{sup 11}C]EADAM) was synthesized in the development of a serotonin transporter (SERT) imaging ligand for positron emission tomography (PET). The methods of ligand synthesis, results of in vitro characterization, {sup 11}C labeling and in vivo micro-PET imaging studies of [{sup 11}C]EADAM in cynomolgus monkey brain are described. {sup 11}C was introduced into N,N-dimethyl-2-(2'-amino-4'-ethylphenylthio)benzylamine () by alkylation of N-methyl-2-(2'-amino-4'-ethylphenylthio)benzylamine () in 32% radiochemical yield (end of bombardment [EOB], decay-corrected from [{sup 11}C]methyl iodide). Competition binding assays in cells stably expressing the transfected human dopamine transporter (DAT), SERT and norepinephrine transporter (NET) labeled with [{sup 3}H]WIN 35428 or [{sup 125}I]RTI-55, [{sup 3}H]citalopram and [{sup 3}H]nisoxetine, respectively, indicated the following order of SERT affinity: ADAM>EADAM>>fluvoxamine. The affinity of EADAM for DAT and NET was 500- and >1000-fold lower, respectively, than for SERT. Micro-PET brain imaging studies in a cynomolgus monkey demonstrated high [{sup 11}C]EADAM uptake in the striatum, thalamus and brainstem. [{sup 11}C]EADAM uptake in these brain regions peaked in less than 60 min following administration of [{sup 11}C]EADAM. The tissue-to-cerebellum ratios of the striatum, thalamus and brainstem were 1.67, 1.71 and 1.63, respectively, at 120 min postinjection of [{sup 11}C]EADAM. Analysis of monkey arterial plasma samples using high-pressure liquid chromatography determined there was no detectable formation of lipophilic radiolabeled metabolites capable of entering the brain. In a displacement experiment with citalopram in a cynomolgus monkey, radioactivity in the striatum, thalamus and brainstem was displaced 20-60 min after administration of citalopram. In a blocking experiment with citalopram in a cynomolgus monkey

  4. [18F]-fluorocholine positron-emission/computed tomography for lymph node staging of patients with prostate cancer: preliminary results of a prospective study

    DEFF Research Database (Denmark)

    Poulsen, Mads; Bouchelouche, Kirsten; Gerke, Oke

    2010-01-01

    To evaluate prospectively [(18)F]-fluorocholine positron-emission/computed tomography (FCH PET/CT) for lymph node staging of prostate cancer before intended curative therapy, and to determine whether imaging 15 or 60 min after radiotracer injection is preferable.......To evaluate prospectively [(18)F]-fluorocholine positron-emission/computed tomography (FCH PET/CT) for lymph node staging of prostate cancer before intended curative therapy, and to determine whether imaging 15 or 60 min after radiotracer injection is preferable....

  5. Cholangiocarcinoma associated with limbic encephalitis and early cerebral abnormalities detected by 2-deoxy-2-[fluorine-18]fluoro-D-glucose integrated with computed tomography-positron emission tomography: a case report.

    Science.gov (United States)

    Schmidt, Sergio L; Schmidt, Juliana J; Tolentino, Julio C; Ferreira, Carlos G; de Almeida, Sergio A; Alvarenga, Regina P; Simoes, Eunice N; Schmidt, Guilherme J; Canedo, Nathalie H S; Chimelli, Leila

    2016-07-20

    Limbic encephalitis was originally described as a rare clinical neuropathological entity involving seizures and neuropsychological disturbances. In this report, we describe cerebral patterns visualized by positron emission tomography in a patient with limbic encephalitis and cholangiocarcinoma. To our knowledge, there is no other description in the literature of cerebral positron emission tomography findings in the setting of limbic encephalitis and subsequent diagnosis of cholangiocarcinoma. We describe a case of a 77-year-old Caucasian man who exhibited persistent cognitive changes 2 years before his death. A cerebral scan obtained at that time by 2-deoxy-2-[fluorine-18]fluoro- D -glucose integrated with computed tomography-positron emission tomography showed low radiotracer uptake in the frontal and temporal lobes. Cerebrospinal fluid analysis indicated the presence of voltage-gated potassium channel antibodies. Three months before the patient's death, a lymph node biopsy indicated a cholangiocarcinoma, and a new cerebral scan obtained by 2-deoxy-2-[fluorine-18]fluoro-D-glucose integrated with computed tomography-positron emission tomography showed an increment in the severity of metabolic deficit in the frontal and parietal lobes, as well as hypometabolism involving the temporal lobes. Two months before the patient's death, cerebral metastases were detected on a contrast-enhanced computed tomographic scan. Postmortem examination revealed a cholangiocarcinoma with multiple metastases including the lungs and lymph nodes. The patient's brain weighed 1300 g, and mild cortical atrophy, ex vacuo dilation of the ventricles, and mild focal thickening of the cerebellar leptomeninges, which were infiltrated by neoplastic epithelial cells, were observed. These findings support the need for continued vigilance in malignancy surveillance in patients with limbic encephalitis and early cerebral positron emission tomographic scan abnormalities. The difficulty in early

  6. Cone-beam computed tomography-synthesized cephalometric study of operated unilateral cleft lip and palate and noncleft children with Class III skeletal relationship.

    Science.gov (United States)

    Lin, Yifan; Fu, Zhen; Ma, Lian; Li, Weiran

    2016-11-01

    Our objective was to compare the craniofacial hard and soft tissue characteristics between children with operated unilateral cleft lip and palate (UCLP) and children with noncleft lip and palate (non-CLP) with a Class III skeletal relationship. The study sample consisted of 30 subjects (18 boys, 12 girls; mean age, 10.21 years) affected by UCLP and 30 non-CLP subjects (17 boys, 13 girls; mean age, 10.19 years) as the control group. All subjects were in the mixed dentition with a Class III skeletal relationship. Cone-beam computed tomography-synthesized cephalograms were traced and evaluated, and craniofacial hard and soft tissue morphologies were compared between the UCLP and non-CLP groups. Maxillary length and gonial angle were 2.66 mm shorter and 3.67° greater, respectively, in the UCLP group than those in the non-CLP group. The SNA and SNB angles describing the sagittal positions of the maxilla and mandible, respectively, relative to the cranial base were significantly smaller in the UCLP group (P plane angle and the growth direction vector were significantly greater in the UCLP group (P = 0.007 and P <0.001, respectively). Lastly, the UCLP group had a more concave soft tissue profile, manifested by a reduced facial convexity angle, as well as an acute nasolabial angle and a more protruded lower lip. Although the 2 groups had similar sagittal intermaxillary relationships, patients in the UCLP group had more retrusive maxillary and mandibular positions relative to the cranial base and more severe vertical discrepancies. Additionally, the soft tissue profiles of patients affected by UCLP were more concave, and the compensatory adaptation was less satisfactory. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  7. Optimised motion tracking for positron emission tomography studies of brain function in awake rats.

    Directory of Open Access Journals (Sweden)

    Andre Z Kyme

    Full Text Available Positron emission tomography (PET is a non-invasive molecular imaging technique using positron-emitting radioisotopes to study functional processes within the body. High resolution PET scanners designed for imaging rodents and non-human primates are now commonplace in preclinical research. Brain imaging in this context, with motion compensation, can potentially enhance the usefulness of PET by avoiding confounds due to anaesthetic drugs and enabling freely moving animals to be imaged during normal and evoked behaviours. Due to the frequent and rapid motion exhibited by alert, awake animals, optimal motion correction requires frequently sampled pose information and precise synchronisation of these data with events in the PET coincidence data stream. Motion measurements should also be as accurate as possible to avoid degrading the excellent spatial resolution provided by state-of-the-art scanners. Here we describe and validate methods for optimised motion tracking suited to the correction of motion in awake rats. A hardware based synchronisation approach is used to achieve temporal alignment of tracker and scanner data to within 10 ms. We explored the impact of motion tracker synchronisation error, pose sampling rate, rate of motion, and marker size on motion correction accuracy. With accurate synchronisation (20 Hz, and a small head marker suitable for awake animal studies, excellent motion correction results were obtained in phantom studies with a variety of continuous motion patterns, including realistic rat motion (<5% bias in mean concentration. Feasibility of the approach was also demonstrated in an awake rat study. We conclude that motion tracking parameters needed for effective motion correction in preclinical brain imaging of awake rats are achievable in the laboratory setting. This could broaden the scope of animal experiments currently possible with PET.

  8. A method for comparing intra-tumoural radioactivity uptake heterogeneity in preclinical positron emission tomography studies

    Energy Technology Data Exchange (ETDEWEB)

    Grafström, Jonas; Ahlzén, Hanna-Stina [Division of Biochemistry, Department of Medical Biochemistry and Biophysics, Karolinska Institutet, SE-17177 Stockholm (Sweden); Stone-Elander, Sharon [Department of Clinical Neuroscience, Karolinska Institutet, SE-17176 Stockholm (Sweden); PET Radiochemistry, Neuroradiology Department, Karolinska University Hospital, SE-17176 Stockholm (Sweden)

    2015-09-08

    Non-uniformity influences the interpretation of nuclear medicine based images and consequently their use in treatment planning and monitoring. However, no standardised method for evaluating and ranking heterogeneity exists. Here, we have developed a general algorithm that provides a ranking and a visualisation of the heterogeneity in small animal positron emission tomography (PET) images. The code of the algorithm was written using the Matrix Laboratory software (MATLAB). Parameters known to influence the heterogeneity (distances between deviating peaks, gradients and size compensations) were incorporated into the algorithm. All data matrices were mathematically constructed in the same format with the aim of maintaining overview and control. Histograms visualising the spread and frequency of contributions to the heterogeneity were also generated. The construction of the algorithm was tested using mathematically generated matrices and by varying post-processing parameters. It was subsequently applied in comparisons of radiotracer uptake in preclinical images in human head and neck carcinoma and endothelial and ovarian carcinoma xenografts. Using the developed algorithm, entire tissue volumes could be assessed and gradients could be handled in an indirect manner. Similar-sized volumes could be compared without modifying the algorithm. Analyses of the distribution of different tracers gave results that were generally in accordance with single plane preclinical images, indicating that it could appropriately handle comparisons of targeting vs. non-targeting tracers and also for different target levels. Altering the reconstruction algorithm, pixel size, tumour ROI volumes and lower cut-off limits affected the calculated heterogeneity factors in expected directions but did not reverse conclusions about which tumour was more or less heterogeneous. The algorithm constructed is an objective and potentially user-friendly tool for one-to-one comparisons of heterogeneity in

  9. Al18F-Labeling Of Heat-Sensitive Biomolecules for Positron Emission Tomography Imaging

    Science.gov (United States)

    Cleeren, Frederik; Lecina, Joan; Ahamed, Muneer; Raes, Geert; Devoogdt, Nick; Caveliers, Vicky; McQuade, Paul; Rubins, Daniel J; Li, Wenping; Verbruggen, Alfons; Xavier, Catarina; Bormans, Guy

    2017-01-01

    Positron emission tomography (PET) using radiolabeled biomolecules is a translational molecular imaging technology that is increasingly used in support of drug development. Current methods for radiolabeling biomolecules with fluorine-18 are laborious and require multistep procedures with moderate labeling yields. The Al18F-labeling strategy involves chelation in aqueous medium of aluminum mono[18F]fluoride ({Al18F}2+) by a suitable chelator conjugated to a biomolecule. However, the need for elevated temperatures (100-120 °C) required for the chelation reaction limits its widespread use. Therefore, we designed a new restrained complexing agent (RESCA) for application of the AlF strategy at room temperature. Methods. The new chelator RESCA was conjugated to three relevant biologicals and the constructs were labeled with {Al18F}2+ to evaluate the generic applicability of the one-step Al18F-RESCA-method. Results. We successfully labeled human serum albumin with excellent radiochemical yields in less than 30 minutes and confirmed in vivo stability of the Al18F-labeled protein in rats. In addition, we efficiently labeled nanobodies targeting the Kupffer cell marker CRIg, and performed µPET studies in healthy and CRIg deficient mice to demonstrate that the proposed radiolabeling method does not affect the functional integrity of the protein. Finally, an affibody targeting HER2 (PEP04314) was labeled site-specifically, and the distribution profile of (±)-[18F]AlF(RESCA)-PEP04314 in a rhesus monkey was compared with that of [18F]AlF(NOTA)-PEP04314 using whole-body PET/CT. Conclusion. This generic radiolabeling method has the potential to be a kit-based fluorine-18 labeling strategy, and could have a large impact on PET radiochemical space, potentially enabling the development of many new fluorine-18 labeled protein-based radiotracers. PMID:28824726

  10. Development of a multiplexed readout with high position resolution for positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sangwon; Choi, Yong [Molecular Imaging Research & Education (MiRe) Laboratory, Department of Electronic Engineering, Sogang University, Seoul 04107 (Korea, Republic of); Kang, Jihoon [Department of Biomedical Engineering, Chonnam National University, Yeosu 550-749 (Korea, Republic of); Jung, Jin Ho [Molecular Imaging Research & Education (MiRe) Laboratory, Department of Electronic Engineering, Sogang University, Seoul 04107 (Korea, Republic of)

    2017-04-01

    Detector signals for positron emission tomography (PET) are commonly multiplexed to reduce the number of digital processing channels so that the system can remain cost effective while also maintaining imaging performance. In this work, a multiplexed readout combining Anger position estimation algorithm and position decoder circuit (PDC) was developed to reduce the number of readout channels by a factor of 24, 96-to-4. The data acquisition module consisted of a TDC (50 ps resolution), 4-channel ADCs (12 bit, 105 MHz sampling rate), 2 GB SDRAM and USB3.0. The performance of the multiplexed readout was assessed with a high-resolution PET detector block composed of 2×3 detector modules, each consisting of an 8×8 array of 1.52×1.52×6 mm{sup 3} LYSO, a 4×4 array of 3×3 mm{sup 2} silicon photomultiplier (SiPM) and 13.4×13.4 mm{sup 2} light guide with 0.7 mm thickness. The acquired flood histogram showed that all 384 crystals could be resolved. The average energy resolution at 511 keV was 13.7±1.6% full-width-at-half-maximum (FWHM) and the peak-to-valley ratios of the flood histogram on the horizontal and vertical lines were 18.8±0.8 and 22.8±1.3, respectively. The coincidence resolving time of a pair of detector blocks was 6.2 ns FWHM. The reconstructed phantom image showed that rods down to a diameter of 1.6 mm could be resolved. The results of this study indicate that the multiplexed readout would be useful in developing a PET with a spatial resolution less than the pixel size of the photosensor, such as a SiPM array.

  11. Pre-clinical Positron Emission Tomography Reconstruction Algorithm Effect on Cu-64 ATSM Lesion Hypoxia

    Directory of Open Access Journals (Sweden)

    Bal Sanghera

    2016-02-01

    Full Text Available Objective: Application of distinct positron emission tomography (PET scan reconstruction algorithms can lead to statistically significant differences in measuring lesion functional properties. We looked at the influence of two-dimensional filtered back projection (2D FBP, two-dimensional ordered subset expectation maximization (2D OSEM, three-dimensional ordered subset expectation maximization (3D OSEM without 3D maximum a posteriori and with (3D OSEM MAP on lesion hypoxia tracer uptake using a pre-clinical PET scanner. Methods: Reconstructed images of a rodent tumor model bearing P22 carcinosarcoma injected with hypoxia tracer Copper- 64-Diacetyl-bis (N4-methylthiosemicarbazone (i.e. Cu-64 ATSM were analyzed at 10 minute intervals till 60 minute post injection. Lesion maximum standardized uptake values (SUVmax and SUVmax/background SUVmean (T/B were recorded and investigated after application of multiple algorithm and reconstruction parameters to assess their influence on Cu-64 ATSM measurements and associated trends over time. Results: SUVmax exhibited convergence for OSEM reconstructions while ANOVA results showed a significant difference in SUVmax or T/B between 2D FBP, 2D OSEM, 3D OSEM and 3D OSEM MAP reconstructions across all time frames. SUVmax and T/B were greatest in magnitude for 2D OSEM followed by 3D OSEM MAP, 3D OSEM and then 2D FBP at all time frames respectively. Similarly SUVmax and T/B standard deviations (SD were lowest for 2D OSEM in comparison with other algorithms. Conclusion: Significantly higher magnitude lesion SUVmax and T/B combined with lower SD were observed using 2D OSEM reconstruction in comparison with 2D FBP, 3D OSEM and 3D OSEM MAP algorithms at all time frames. Results are consistent with other published studies however more specimens are required for full validation.

  12. Dosage optimization in positron emission tomography: state-of-the-art methods and future prospects.

    Science.gov (United States)

    Karakatsanis, Nicolas A; Fokou, Eleni; Tsoumpas, Charalampos

    2015-01-01

    Positron emission tomography (PET) is widely used nowadays for tumor staging and therapy response in the clinic. However, average PET radiation exposure has increased due to higher PET utilization. This study aims to review state-of-the-art PET tracer dosage optimization methods after accounting for the effects of human body attenuation and scan protocol parameters on the counting rate. In particular, the relationship between the noise equivalent count rate (NECR) and the dosage (NECR-dosage curve) for a range of clinical PET systems and body attenuation sizes will be systematically studied to prospectively estimate the minimum dosage required for sufficiently high NECR. The optimization criterion can be determined either as a function of the peak of the NECR-dosage curve or as a fixed NECR score when NECR uniformity across a patient population is important. In addition, the systematic NECR assessments within a controllable environment of realistic simulations and phantom experiments can lead to a NECR-dosage response model, capable of predicting the optimal dosage for every individual PET scan. Unlike conventional guidelines suggesting considerably large dosage levels for obese patients, NECR-based optimization recommends: i) moderate dosage to achieve 90% of peak NECR for obese patients, ii) considerable dosage reduction for slimmer patients such that uniform NECR is attained across the patient population, and iii) prolongation of scans for PET/MR protocols, where longer PET acquisitions are affordable due to lengthy MR sequences, with motion compensation becoming important then. Finally, the need for continuous adaptation of dosage optimization to emerging technologies will be discussed.

  13. Vision 20/20: Positron emission tomography in radiation therapy planning, delivery, and monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Parodi, Katia, E-mail: Katia.parodi@physik.uni-muenchen.de [Faculty of Physics, Department of Medical Physics, Ludwig Maximilians University Munich, Munich 85748 (Germany)

    2015-12-15

    Positron emission tomography (PET) is increasingly considered as an effective imaging method to support several stages of radiation therapy. The combined usage of functional and morphological imaging in state-of-the-art PET/CT scanners is rapidly emerging to support the treatment planning process in terms of improved tumor delineation, and to assess the tumor response in follow-up investigations after or even during the course of fractionated therapy. Moreover, active research is being pursued on new tracers capable of providing different insights into tumor function, in order to identify areas of the planning volume which may require additional dosage for improved probability of tumor control. In this respect, major progresses in the next years will likely concern the development and clinical investigation of novel tracers and image processing techniques for reliable thresholding and segmentation, of treatment planning and beam delivery approaches integrating the PET imaging information, as well as improved multimodal clinical instrumentation such as PET/MR. But especially in the rapidly emerging case of ion beam therapy, the usage of PET is not only limited to the imaging of external tracers injected to the patient. In fact, a minor amount of positron emitters is formed in nuclear fragmentation reactions between the impinging ions and the tissue, bearing useful information for confirmation of the delivered treatment during or after therapeutic irradiation. Different implementations of unconventional PET imaging for therapy monitoring are currently being investigated clinically, and major ongoing research aims at new dedicated detector technologies and at challenging applications such as real-time imaging and time-resolved in vivo verification of motion compensated beam delivery. This paper provides an overview of the different areas of application of PET in radiation oncology and discusses the most promising perspectives in the years to come for radiation therapy

  14. What have positron emission tomography and 'Zippy' told us about the neuropharmacology of drug addiction?

    Science.gov (United States)

    Cumming, Paul; Caprioli, Daniele; Dalley, Jeffrey W

    2011-08-01

    Translational molecular imaging with positron emission tomography (PET) and allied technologies offer unrivalled applications in the discovery of biomarkers and aetiological mechanisms relevant to human disease. Foremost among clinical PET findings during the past two decades of addiction research is the seminal discovery of reduced dopamine D(2/3) receptor expression in the striatum of drug addicts, which could indicate a predisposing factor and/or compensatory reaction to the chronic abuse of stimulant drugs. In parallel, recent years have witnessed significant improvements in the performance of small animal tomographs (microPET) and a refinement of animal models of addiction based on clinically relevant diagnostic criteria. This review surveys the utility of PET in the elucidation of neuropharmacological mechanisms underlying drug addiction. It considers the consequences of chronic drug exposure on regional brain metabolism and neurotransmitter function and identifies those areas where further research is needed, especially concerning the implementation of PET tracers targeting neurotransmitter systems other than dopamine, which increasingly have been implicated in the pathophysiology of drug addiction. In addition, this review considers the causal effects of behavioural traits such as impulsivity and novelty/sensation-seeking on the emergence of compulsive drug-taking. Previous research indicates that spontaneously high-impulsive rats--as exemplified by 'Zippy'--are pre-disposed to escalate intravenous cocaine self-administration, and subsequently to develop compulsive drug taking tendencies that endure despite concurrent adverse consequences of such behaviour, just as in human addiction. The discovery using microPET of pre-existing differences in dopamine D(2/3) receptor expression in the striatum of high-impulsive rats suggests a neural endophenotype that may likewise pre-dispose to stimulant addiction in humans. © 2011 The Authors. British Journal of

  15. Potential requirement of positron emission tomography apparatuses in Asia and latin america including Mexico.

    Science.gov (United States)

    Watanabe, Naoyuki; Padhy, Ajit Kumar; Oku, Shinya; Sasaki, Yasuhito

    2013-01-01

    The number of positron emission tomography (PET) machines has been increasing in regions of East-, Southeast-, and South-Asia as well as in Latin America including Mexico. This study was performed to assess the potential requirement of PET machines in 19 countries which already use PET in the aforementioned regions. Data on the number of PET machines and internationally available characteristics of the restrictive countries such as the land area, the total population, the gross national income (GNI), and the average life span of inhabitants were obtained from IAEA, UN, WB, and WHO. Correlation between the number of PET machines and the characteristics of each country was evaluated. The potentially required number of PET machines, which was obtained by adjusting the number of PET machines with statistically significant, correlative characteristics of each country, standardized on the state of Japan, were compared. The number of PET machines could be significantly correlated to the GNI of a country and the average life span of its inhabitants (P machines. With installation of the potentially required number of PET machines in each of the countries, the number of PET machine per 10(6) population would increase by 1.1- to 12-fold, in comparison with the current situation. With regards to the potentially required number of PET machines, most of the countries in these regions may require a considerable increase of PET machines. Nevertheless, some countries in the Asia seem to require outside assistance such as international support in order to introduce PET and enhance the efficacy of their health services.

  16. Noninvasive evaluation of sympathetic nervous system in human heart by positron emission tomography.

    Science.gov (United States)

    Schwaiger, M; Kalff, V; Rosenspire, K; Haka, M S; Molina, E; Hutchins, G D; Deeb, M; Wolfe, E; Wieland, D M

    1990-08-01

    The noninvasive functional characterization of the cardiac sympathetic nervous system by imaging techniques may provide important pathophysiological information in various cardiac disease states. Hydroxyephedrine labeled with carbon 11 has been developed as a new catecholamine analogue to be used in the in vivo evaluation of presynaptic adrenergic nerve terminals by positron emission tomography (PET). To determine the feasibility of this imaging approach in the human heart, six normal volunteers and five patients with recent cardiac transplants underwent dynamic PET imaging after intravenous injection of 20 mCi [11C]hydroxyephedrine. Blood and myocardial tracer kinetics were assessed using a regions-of-interest approach. In normal volunteers, blood 11C activity cleared rapidly, whereas myocardium retained 11C activity with a long tissue half-life. Relative tracer retention in the myocardium averaged 79 +/- 31% of peak activity at 60 minutes after tracer injection. The heart-to-blood 11C activity ratio exceeded 6:1 as soon as 30 minutes after tracer injection, yielding excellent image quality. Little regional variation of tracer retention was observed, indicating homogeneous sympathetic innervation throughout the left ventricle. In the transplant recipients, myocardial [11C]hydroxyephedrine retention at 60 minutes was significantly less (-82%) than that of normal volunteers, indicating only little non-neuronal binding of the tracer in the denervated human heart. Thus, [11C]hydroxyephedrine, in combination with dynamic PET imaging, allows the noninvasive delineation of myocardial adrenergic nerve terminals. Tracer kinetic modeling may permit quantitative assessment of myocardial catecholamine uptake, which will in turn provide insights into the effects of various disease processes on the neuronal integrity of the heart.

  17. Cerebral lesions and event-related potential P300 using positron emission tomography (PET)

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Yasujiro; Okamoto, Kazuma; Tanaka, Makoto; Kondoh, Susumu; Hirai, Shunsaku (Gunma Univ., Maebashi (Japan). School of Medicine)

    1993-06-01

    To determine what lesions are involved in prolonging event-related potential P300 latency, regional cerebral blood flow (rCBF) and metabolism were investigated by positron emission tomography (PET) in a total of 40 patients with neurologic diseases (12 with chronic cerebrovascular disorder, 9 with spino-cerebellar degeneration, 4 with Alzheimer's type dementia, 4 with amyotrophic lateral sclerosis, and 11 with miscellaneous diseases). There was inverse correlation between rCBF and P300 latency in terms of any of the whole, left, and right hemispheres: P300 latency was associated with decreased rCBF. This was more noticeable in the cerebral cortex than white matter and in the right than left hemisphere, although there was no significant difference between them. In none of the regions, however, was there significant correlation between cerebral oxygen consumption and P300 latency. When the right and left frontal, temporal, parietal and occipital cortexes, thalamus, putamen, and caudatum were examined as regions of interest, there was significantly inverse correlation between rCBF and P300 latency in all regions except for the occipital cortex. This was more noticeable on the right than the left side, although no significant difference was observed. Cerebral oxygen consumption in these lesions did not correlate with P300 latency. In the study on bilateral rCBF difference, decreased rCBF confined to the right parietal lobe, bilateral thalamus and bilateral temporal lobes was found to be associated with a significantly prolonged P300 latency. Thus, rCBF in these regions seemed to be particularly responsible for P300 latency. (N.K.).

  18. The Positron Emission Tomography. A diagnostic technique; Con la PET diagnosi precoce della malattia

    Energy Technology Data Exchange (ETDEWEB)

    Salvadori, P. [Consiglio Nazionale delle Ricerche, Istituto di Fisiologia Clinica, Chimica e Radiofarmaceutica, Gruppo PET/Ciclotrone, Pisa (Italy)

    2001-07-01

    Positron Emission Tomography (PET) is a new imaging modality, which is able to assess non-invasively the biochemical mechanisms, underlying physiological and pathophysiological processes in vivo in humans. The technique relies on the administration of radioactive tracers labeled with short-lived positron emitters, which need to be produced on site via a particle accelerator (cyclotron). Radionuclides are produced upon request and formulated into biologically active organic molecules having precise pharmacokinetics and specificity. The radiotracer can be detected by the PET scanner and represented as tomographic sections (images of body sections) showing its regional distribution and concentration. This makes it possible to address clinical questions concerning occurrence and evolution of many diseases as well as their response to therapy. The ability to image (measure) biological processes and not only anatomy enables PET to explore diseases in the very early stage, including those diseases which are not related to modifications of organ structure (e.g. psychiatric diseases, metabolic disorders, biochemical disfunction). PET plays a major role, in conjunction with the other imaging modalities, to improve diagnosis capabilities and disease mechanism understanding. [Italian] La PET e' correntemente utilizzata come efficace strumento clinico, per l'elevata sensibilita' e specificita', nella valutazione dell'iter diagnostico di pazienti con sospetta cardiopatia ischemica e nel processo di decision making clinico di pazienti con disfunzione ventricolare sinistra e cardiopatia ischemica, in quanto metodica di riferimento per la diagnosi di vitalita' miocardica. In campo oncologico, viene impiegata l'ormai ben documentata capacita' del fluorodesossiglucosio (FDG), un tracciante contenente fluoro-18 ed in grado di permettere la misura del consumo cellulare di glucosio, nel porre in evidenza all'esame PET il tessuto neoplastico

  19. Positron emission tomography quantification of serotonin transporter in suicide attempters with major depressive disorder.

    Science.gov (United States)

    Miller, Jeffrey M; Hesselgrave, Natalie; Ogden, R Todd; Sullivan, Gregory M; Oquendo, Maria A; Mann, J John; Parsey, Ramin V

    2013-08-15

    Several lines of evidence implicate abnormal serotonergic function in suicidal behavior and completed suicide, including low serotonin transporter binding in postmortem studies of completed suicide. We have also reported low in vivo serotonin transporter binding in major depressive disorder (MDD) during a major depressive episode using positron emission tomography (PET) with [(11)C]McN5652. We quantified regional brain serotonin transporter binding in vivo in depressed suicide attempters, depressed nonattempters, and healthy controls using PET and a superior radiotracer, [(11)C]DASB. Fifty-one subjects with DSM-IV current MDD, 15 of whom were past suicide attempters, and 32 healthy control subjects underwent PET scanning with [(11)C]DASB to quantify in vivo regional brain serotonin transporter binding. Metabolite-corrected arterial input functions and plasma free-fraction were acquired to improve quantification. Depressed suicide attempters had lower serotonin transporter binding in midbrain compared with depressed nonattempters (p = .031) and control subjects (p = .0093). There was no difference in serotonin transporter binding comparing all depressed subjects with healthy control subjects considering six a priori regions of interest simultaneously (p = .41). Low midbrain serotonin transporter binding appears to be related to the pathophysiology of suicidal behavior rather than of major depressive disorder. This is consistent with postmortem work showing low midbrain serotonin transporter binding capacity in depressed suicides and may partially explain discrepant in vivo findings quantifying serotonin transporter in depression. Future studies should investigate midbrain serotonin transporter binding as a predictor of suicidal behavior in MDD and determine the cause of low binding. Copyright © 2013 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  20. Differentiating cardiomyopathy of coronary artery disease from nonischemic dilated cardiomyopathy utilizing positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Mody, F.V.; Brunken, R.C.; Stevenson, L.W.; Nienaber, C.A.; Phelps, M.E.; Schelbert, H.R. (Univ. of California, Los Angeles (USA))

    1991-02-01

    To determine if imaging of blood flow (using N-13 ammonia) and glucose metabolism (using F-18 2-deoxyglucose) with positron emission tomography can distinguish cardiomyopathy of coronary artery disease from nonischemic dilated cardiomyopathy, 21 patients with severe left ventricular dysfunction who were evaluated for cardiac transplantation were studied. The origin of left ventricular dysfunction had been previously determined by coronary angiography to be ischemic (11 patients) or nonischemic (10 patients). Images were visually analyzed by three observers on a graded scale in seven left ventricular segments and revealed fewer defects in dilated cardiomyopathy compared with ischemic cardiomyopathy for N-13 ammonia (2.7 +/- 1.6 versus 5 +/- 0.6; p less than 0.03) and F-18 deoxyglucose (2.8 +/- 2.1 versus 4.6 +/- 1.1; p less than 0.03). An index incorporating extent and severity of defects revealed more homogeneity with fewer and less severe defects in subjects with nonischemic than in those with ischemic cardiomyopathy as assessed by imaging of flow (2.8 +/- 1.8 versus 9.2 +/- 3; p less than 0.001) and metabolism (3.8 +/- 3.3 versus 8.5 +/- 3.6; p less than 0.005). Diagnostic accuracy for distinguishing the two subgroups by visual image analysis was 85%. Using previously published circumferential count profile criteria, patients with dilated cardiomyopathy had fewer ischemic segments (0.4 +/- 0.8 versus 2.5 +/- 2 per patient; p less than 0.01) and infarcted segments (0.1 +/- 0.3 versus 2.4 +/- 1.4 per patient; p less than 0.001) than did patients with cardiomyopathy of coronary artery disease. The sensitivity for differentiating the two clinical subgroups using circumferential profile analysis was 100% and the specificity 80%.

  1. [Nationwide survey on radioactive waste management related to positron emission tomography in Japan].

    Science.gov (United States)

    Nagaoka, Hiroaki; Watanabe, Hiroshi; Yamaguchi, Ichiro; Fujibuchi, Toshioh; Kida, Tetsuo; Tanaka, Shinji

    2009-12-20

    A clearance system for medical radioactive solid waste has not yet been implemented in Japan. Since 2004 new regulations have allowed institutions using positron emission tomography(PET)to handle totally decayed radioactive waste as non-radioactive waste after decay-in-storage. It was expected that this new regulation would mediate the installation of clearance systems in Japan. In order to assess the current situation of radiation safety management in PET institutions, we conducted a nationwide survey. The study design was a cross-sectional descriptive study conducted by questionnaire. The subjects of this survey were all the PET institutions in Japan. Among 224 institutes, 128 institutes are equipped with cyclotrons and 96 institutes are not. The number of returned questionnaires was 138. Among institutes that are using delivered radiopharmaceuticals, 80% treat their waste as non-radioactive according to the new regulation. The impact of new regulations for reducing radioactive waste in PET institutes without a cyclotron was estimated at about $400 thousand per year. The main concern of medical institutes was assessment of the contamination caused by by-products of radioactive nuclides generated in target water during the operation of a cyclotron. It was thought that a rational rule based on scientific risk management should be established because these by-products of radioactive nuclides are negligible for radiation safety. New regulation has had a good influence on medical PET institutes, and it is expected that a clearance system for medical radioactive waste will be introduced in the near future, following these recent experiences in PET institutes.

  2. HaloTag: a novel reporter gene for positron emission tomography.

    Science.gov (United States)

    Hong, Hao; Benink, Hélène A; Zhang, Yin; Yang, Yunan; Uyeda, H Tetsuo; Engle, Jonathan W; Severin, Gregory W; McDougall, Mark G; Barnhart, Todd E; Klaubert, Dieter H; Nickles, Robert J; Fan, Frank; Cai, Weibo

    2011-08-15

    Among the many molecular imaging techniques, reporter gene imaging has been a dynamic area of research. The HaloTag protein is a modified haloalkane dehalogenase which was designed to covalently bind to synthetic ligands (i.e. the HaloTag ligands [HTL]). Covalent bond formation between the HaloTag protein and the chloroal-kane within the HTL occurs rapidly under physiological conditions, which is highly specific and essentially irreversible. Over the years, HaloTag technology has been investigated for various applications such as in vitro/in vivo imaging, protein purification/trafficking, high-throughput assays, among others. The goal of this study is to explore the use of the HaloTag protein as a novel reporter gene for positron emission tomography (PET) imaging. By attaching a HaloTag -reactive chloroalkane to 1, 4, 7-triazacyclononane-N, N', N"-triacetic acid (NOTA) through hydrophilic linkers, the resulting NOTA-conjugated HTLs were labeled with (64)Cu and tested for PET imaging in living mice bearing 4T1-HaloTag-ECS tumors, which stably express the HaloTag protein on the cell surface. Significantly higher uptake of (64)Cu-NOTA-HTL-S (which contains a short hydrophilic linker) in the 4T1-HaloTag-ECS than the non-HaloTag-expressing 4T1 tumors was observed, which demonstrated the HaloTag specificity of (64)Cu-NOTA-HTL-S and warranted future investigation of the HaloTag protein as a PET reporter gene.

  3. Activity-based costing evaluation of a [(18)F]-fludeoxyglucose positron emission tomography study.

    Science.gov (United States)

    Krug, Bruno; Van Zanten, Annie; Pirson, Anne-Sophie; Crott, Ralph; Borght, Thierry Vander

    2009-10-01

    The aim of the study is to use the activity-based costing approach to give a better insight in the actual cost structure of a positron emission tomography procedure (FDG-PET) by defining the constituting components and by simulating the impact of possible resource or practice changes. The cost data were obtained from the hospital administration, personnel and vendor interviews as well as from structured questionnaires. A process map separates the process in 16 patient- and non-patient-related activities, to which the detailed cost data are related. One-way sensitivity analyses shows to which degree of uncertainty the different parameters affect the individual cost and evaluate the impact of possible resource or practice changes like the acquisition of a hybrid PET/CT device, the patient throughput or the sales price of a 370MBq (18)F-FDG patient dose. The PET centre spends 73% of time in clinical activities and the resting time after injection of the tracer (42%) is the single largest departmental cost element. The tracer cost and the operational time have the most influence on cost per procedure. The analysis shows a total cost per FDG-PET ranging from 859 Euro for a BGO PET camera to 1142 Euro for a 16 slices PET-CT system, with a distribution of the resource costs in decreasing order: materials (44%), equipment (24%), wage (16%), space (6%) and hospital overhead (10%). The cost of FDG-PET is mainly influenced by the cost of the radiopharmaceutical. Therefore, the latter rather than the operational time should be reduced in order to improve its cost-effectiveness.

  4. {sup 18}F-FDG positron emission tomography in the early diagnosis of enterocolitis: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Kresnik, E.; Gallowitsch, H.J.; Igerc, I.; Kumnig, G.; Gomez, I.; Lind, P. [Nuclear Medicine and Special Endocrinology, PET Centre, General Hospital, St. Veiterstrasse 47, 9020 Klagenfurt (Austria); Mikosch, P.; Alberer, D.; Hebenstreit, A. [Department of Internal Medicine and Gastroenterology, General Hospital, Klagenfurt (Austria); Wuertz, F. [Department of Pathology, General Hospital, Klagenfurt (Austria); Kogler, D.; Gasser, J. [Department of Radiology, General Hospital, Klagenfurt (Austria)

    2002-10-01

    Collagenous and eosinophilic colitis are rare diseases characterised by chronic watery diarrhoea. Radiographic evaluation of the gastrointestinal tract and colonoscopy are usually non-diagnostic since as many as one-third of patients will have minor abnormalities. To date a few investigators have reported increased fluorine-18 fluorodeoxyglucose ({sup 18}F-FDG) uptake on positron emission tomography (PET) in patients with acute enterocolitis, but there have been no reports on the use of {sup 18}F-FDG PET for the diagnosis of collagenous or eosinophilic colitis in an early clinical stage. The aim of this preliminary study was to evaluate the usefulness of {sup 18}F-FDG PET in the early diagnosis of patients with colitis. We investigated five women (mean age 61.2{+-}12.1 years) who had been diagnosed as having colitis in an early clinical stage. In all but one of the patients, the diagnosis of colitis was based on biopsy. Magnetic resonance colonography, ultrasonography and colonoscopy were performed in all but one of the patients. Two women were identified as having collagenous colitis in an early clinical stage. Another two patients had eosinophilic colitis. The morphological imaging methods, magnetic resonance colonography and ultrasonography, yielded no suspicious findings, and the results of colonoscopy similarly showed no abnormalities. One patient had colitis due to bacterial infection. In all patients {sup 18}F-FDG PET showed a pathological increase in tracer uptake in the large bowel, suggestive of colitis. In four of the five patients, colitis was confirmed by histology, and in one, by bacterial analysis. {sup 18}F-FDG PET was able to detect colitis in an early clinical stage, when morphological imaging methods and colonoscopy were non-diagnostic. The early performance of {sup 18}F-FDG PET imaging in patients with possible colitis is encouraging. (orig.)

  5. Dopamine D1 receptor availability is related to social behavior: a positron emission tomography study.

    Science.gov (United States)

    Plavén-Sigray, Pontus; Gustavsson, Petter; Farde, Lars; Borg, Jacqueline; Stenkrona, Per; Nyberg, Lars; Bäckman, Lars; Cervenka, Simon

    2014-11-15

    Dysfunctional interpersonal behavior is thought to underlie a wide spectrum of psychiatric disorders; however, the neurobiological underpinnings of these behavioral disturbances are poorly understood. Previous molecular imaging studies have shown associations between striatal dopamine (DA) D2-receptor binding and interpersonal traits, such as social conformity. The objective of this study was to explore, for the first time, the role of DA D1-receptors (D1-Rs) in human interpersonal behavior. Twenty-three healthy subjects were examined using positron emission tomography and the radioligand [(11)C]SCH23390, yielding D1-R binding potential values. Striatal D1-R binding was related to personality scales selected to specifically assess one dimension of interpersonal behavior, namely a combination of affiliation and dominance (i.e., the Social Desirability, Verbal Trait Aggression and Physical Trait Aggression scales from Swedish Universities Scales of Personality). An exploratory analysis was also performed for extrastriatal brain regions. D1-R binding potential values in the limbic striatum (r = .52; p = .015), associative striatum (r = .55; p = .009), and sensorimotor striatum (r = .67; p = .001) were positively related to Social Desirability scores. D1-R binding potential in the limbic striatum (r = -.51; p = .019) was negatively associated with Physical Trait Aggression scores. For extrastriatal regions, Social Desirability scores showed positive correlations in the amygdala (r = .60; p = .006) and medial frontal cortex (r = .60; p = .004). This study provides further support for the role of DA function in the expression of disaffiliative and dominant traits. Specifically, D1-R availability may serve as a marker for interpersonal behavior in humans. Associations were demonstrated for the same dimension of interpersonal behavior as for D2-R, but in the opposite direction, suggesting that the two receptor subtypes are involved in the same behavioral processes, but

  6. Carotid body autotransplantation in Parkinson disease: a clinical and positron emission tomography study

    Science.gov (United States)

    Mínguez‐Castellanos, Adolfo; Escamilla‐Sevilla, Francisco; Hotton, Gary R; Toledo‐Aral, Juan J; Ortega‐Moreno, Ángel; Méndez‐Ferrer, Simón; Martín‐Linares, José M; Katati, Majed J; Mir, Pablo; Villadiego, Javier; Meersmans, Miguel; Pérez‐García, Miguel; Brooks, David J; Arjona, Ventura; López‐Barneo, José

    2007-01-01

    Background Carotid body (CB) glomus cells are highly dopaminergic and express the glial cell line derived neurotrophic factor. The intrastriatal grafting of CB cell aggregates exerts neurotrophic actions on nigrostriatal neurons in animal models of Parkinson disease (PD). Objective We conducted a phase I–II clinical study to assess the feasibility, long term safety, clinical and neurochemical effects of intrastriatal CB autotransplantation in patients with PD. Methods Thirteen patients with advanced PD underwent bilateral stereotactic implantation of CB cell aggregates into the striatum. They were assessed before surgery and up to 1–3 years after surgery according to CAPIT (Core Assessment Programme for Intracerebral Transplantation) and CAPSIT‐PD (Core Assessment Programme for Surgical Interventional Therapies in Parkinson's Disease) protocols. The primary outcome measure was the change in video blinded Unified Parkinson's Disease Rating Scale III score in the off‐medication state. Seven patients had 18F‐dopa positron emission tomography scans before and 1 year after transplantation. Results Clinical amelioration in the primary outcome measure was observed in 10 of 12 blindly analysed patients, which was maximal at 6–12 months after transplantation (5–74%). Overall, mean improvement at 6 months was 23%. In the long term (3 years), 3 of 6 patients still maintained improvement (15–48%). None of the patients developed off‐period dyskinesias. The main predictive factors for motor improvement were the histological integrity of the CB and a milder disease severity. We observed a non‐significant 5% increase in mean putaminal 18F‐dopa uptake but there was an inverse relationship between clinical amelioration and annual decline in putaminal 18F‐dopa uptake (r = −0.829; p = 0.042). Conclusions CB autotransplantation may induce clinical effects in patients with advanced PD which seem partly related to the biological properties of

  7. Concept of an upright wearable positron emission tomography imager in humans.

    Science.gov (United States)

    Bauer, Christopher E; Brefczynski-Lewis, Julie; Marano, Gary; Mandich, Mary-Beth; Stolin, Alexander; Martone, Peter; Lewis, James W; Jaliparthi, Gangadhar; Raylman, Raymond R; Majewski, Stan

    2016-09-01

    Positron Emission Tomography (PET) is traditionally used to image patients in restrictive positions, with few devices allowing for upright, brain-dedicated imaging. Our team has explored the concept of wearable PET imagers which could provide functional brain imaging of freely moving subjects. To test feasibility and determine future considerations for development, we built a rudimentary proof-of-concept prototype (Helmet_PET) and conducted tests in phantoms and four human volunteers. Twelve Silicon Photomultiplier-based detectors were assembled in a ring with exterior weight support and an interior mechanism that could be adjustably fitted to the head. We conducted brain phantom tests as well as scanned four patients scheduled for diagnostic F(18-) FDG PET/CT imaging. For human subjects the imager was angled such that field of view included basal ganglia and visual cortex to test for typical resting-state pattern. Imaging in two subjects was performed ~4 hr after PET/CT imaging to simulate lower injected F(18-) FDG dose by taking advantage of the natural radioactive decay of the tracer (F(18) half-life of 110 min), with an estimated imaging dosage of 25% of the standard. We found that imaging with a simple lightweight ring of detectors was feasible using a fraction of the standard radioligand dose. Activity levels in the human participants were quantitatively similar to standard PET in a set of anatomical ROIs. Typical resting-state brain pattern activation was demonstrated even in a 1 min scan of active head rotation. To our knowledge, this is the first demonstration of imaging a human subject with a novel wearable PET imager that moves with robust head movements. We discuss potential research and clinical applications that will drive the design of a fully functional device. Designs will need to consider trade-offs between a low weight device with high mobility and a heavier device with greater sensitivity and larger field of view.

  8. Tomography of the fast electron Bremsstrahlung emission during lower hybrid current drive on Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Peysson, Y.; Imbeaux, F. [Association Euratom-CEA, CEA/Cadarache, Dept. de Recherches sur la Fusion Controlee (DRFC), 13 - Saint-Paul-lez-Durance (France)

    1999-04-01

    A new tomography dedicated to detailed studies of the fast electron Bremsstrahlung emission in the hard X-ray (HXR) energy range between 20 and 200 keV during lower hybrid (LH) current drive experiments on the TORE SUPRA tokamak [Equipe TORE SUPRA, in Proceedings of the 15. Conference on Plasma Physics and Controlled Nuclear Fusion Research, Seville (International Atomic Energy Agency, Vienna, 1995), 1, AIEA-CN-60 / A1-5, p. 105] is presented. Radiation detection is performed by cadmium telluride(CdTe) semiconductors, which have most of the desirable features for a powerful diagnosing of magnetically confined hot plasmas - compact size, high X-ray stopping efficiency, fast timing characteristics, good energy resolution, no sensitivity to magnetic field, reasonable susceptibility to performance degradation from neutron/{gamma}-induced damages. This instrument is made of two independent cameras viewing a poloidal cross-section of the plasma, with respectively 21 and 38 detectors. A coarse spectrometry - 8 energy channels - is carried out for each chord, with an energy resolution of 20 keV. The spatial resolution in the core of the plasma is 4-5 cm, while the time sampling may be lowered down to of 2-4 ms. Powerful inversion techniques based on maximum entropy or regularization algorithms take fully advantage of the large number of line-integrated measurements for very robust estimates of the local HXR profiles as a function of time and photon energy. A detailed account of main characteristics and performances of the diagnostic is reported as well as preliminary results on LH current drive experiments. (authors)

  9. Dipyridamole-loading scintigraphy in patients with subendocardial infarction using single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Kiyoo; Masuda, Masanosuke (Hoju Memorial Hospital, Tatsunokuchi, Ishikawa (Japan)); Bunkou, Hisashi

    1988-12-01

    To detect myocardial lesions in patients with subendocardial (nontransmural) infarction, myocardial perfusion images of thallium-201 (Tl-201), using single photon emission computed tomography, were obtained in 17 patients during and three hours after coronary vasodilatation induced by the administration of dipyridamole. Controls consisted of 28 patients with transmural infarction and 11 with angina pectoris. Dipyridamole was infused intravenously at a rate of 0.142 mg/kg per min for four min, and the washout rate of Tl-201 was calculated by the segmental ROI method. Many patients with nontransmural infarction exhibited various Tl-201 myocardial perfusion images. The prevalence of redistribution among patients with nontransmural infarction was 88.2% (15 of 17), and its reverse redistribution was 64.7% (11 of 17). Every subject exhibited a number of abnormal Tl-201 myocardial perfusion images. In patients with nontransmural infarction the occurence of reverse redistribution images was significantly higher (64.7%) compared to those with transmural infarction (10.7%), and the occurrence of redistribution images was significantly higher (88.2%) compared to those with angina pectoris (45.5%). The abnormal perfusion images most frequently present in the areas corresponding to the sites of ST-T changes on ECG were reverse redistribution (26.7%), redistribution (17.3%), and fixed defect (6.7%) in order. The phenomenon of reverse redistribution images was found irrespective of stenotic coronary artery lesions on selective coronary angiography. Most areas corresponding to the sites of reverse redistribution showed ST-T changes on ECG and high washout rates of Tl-201. (J.P.N.).

  10. A multiresolution image based approach for correction of partial volume effects in emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Boussion, N; Hatt, M; Lamare, F; Bizais, Y; Turzo, A; Rest, C Cheze-Le; Visvikis, D [INSERM U650, Laboratoire du Traitement de l' Information Medicale (LaTIM), CHU Morvan, Brest (France)

    2006-04-07

    Partial volume effects (PVEs) are consequences of the limited spatial resolution in emission tomography. They lead to a loss of signal in tissues of size similar to the point spread function and induce activity spillover between regions. Although PVE can be corrected for by using algorithms that provide the correct radioactivity concentration in a series of regions of interest (ROIs), so far little attention has been given to the possibility of creating improved images as a result of PVE correction. Potential advantages of PVE-corrected images include the ability to accurately delineate functional volumes as well as improving tumour-to-background ratio, resulting in an associated improvement in the analysis of response to therapy studies and diagnostic examinations, respectively. The objective of our study was therefore to develop a methodology for PVE correction not only to enable the accurate recuperation of activity concentrations, but also to generate PVE-corrected images. In the multiresolution analysis that we define here, details of a high-resolution image H (MRI or CT) are extracted, transformed and integrated in a low-resolution image L (PET or SPECT). A discrete wavelet transform of both H and L images is performed by using the 'a trous' algorithm, which allows the spatial frequencies (details, edges, textures) to be obtained easily at a level of resolution common to H and L. A model is then inferred to build the lacking details of L from the high-frequency details in H. The process was successfully tested on synthetic and simulated data, proving the ability to obtain accurately corrected images. Quantitative PVE correction was found to be comparable with a method considered as a reference but limited to ROI analyses. Visual improvement and quantitative correction were also obtained in two examples of clinical images, the first using a combined PET/CT scanner with a lymphoma patient and the second using a FDG brain PET and corresponding T1

  11. Least-squares dual characterization for ROI assessment in emission tomography

    Science.gov (United States)

    Ben Bouallègue, F.; Crouzet, J. F.; Dubois, A.; Buvat, I.; Mariano-Goulart, D.

    2013-06-01

    Our aim is to describe an original method for estimating the statistical properties of regions of interest (ROIs) in emission tomography. Drawn upon the works of Louis on the approximate inverse, we propose a dual formulation of the ROI estimation problem to derive the ROI activity and variance directly from the measured data without any image reconstruction. The method requires the definition of an ROI characteristic function that can be extracted from a co-registered morphological image. This characteristic function can be smoothed to optimize the resolution-variance tradeoff. An iterative procedure is detailed for the solution of the dual problem in the least-squares sense (least-squares dual (LSD) characterization), and a linear extrapolation scheme is described to compensate for sampling partial volume effect and reduce the estimation bias (LSD-ex). LSD and LSD-ex are compared with classical ROI estimation using pixel summation after image reconstruction and with Huesman's method. For this comparison, we used Monte Carlo simulations (GATE simulation tool) of 2D PET data of a Hoffman brain phantom containing three small uniform high-contrast ROIs and a large non-uniform low-contrast ROI. Our results show that the performances of LSD characterization are at least as good as those of the classical methods in terms of root mean square (RMS) error. For the three small tumor regions, LSD-ex allows a reduction in the estimation bias by up to 14%, resulting in a reduction in the RMS error of up to 8.5%, compared with the optimal classical estimation. For the large non-specific region, LSD using appropriate smoothing could intuitively and efficiently handle the resolution-variance tradeoff.

  12. Glycine transporter type 1 occupancy by bitopertin: a positron emission tomography study in healthy volunteers.

    Science.gov (United States)

    Martin-Facklam, Meret; Pizzagalli, Flavia; Zhou, Yun; Ostrowitzki, Susanne; Raymont, Vanessa; Brašić, James R; Parkar, Nikhat; Umbricht, Daniel; Dannals, Robert F; Goldwater, Ron; Wong, Dean F

    2013-02-01

    Deficient N-methyl-D-aspartate (NMDA) receptor transmission is thought to underlie schizophrenia. An approach for normalizing glutamate neurotransmission by enhancing NMDA receptor transmission is to increase glycine availability by inhibiting the glycine transporter type 1 (GlyT1). This study investigated the relationship between the plasma concentration of the glycine reuptake inhibitor bitopertin (RG1678) and brain GlyT1 occupancy. Healthy male volunteers received up to 175 mg bitopertin once daily, for 10-12 days. Three positron emission tomography scans, preceded by a single intravenous infusion of ∼30 mCi [(11)C]RO5013853, were performed: at baseline, on the last day of bitopertin treatment, and 2 days after drug discontinuation. Eighteen subjects were enrolled. At baseline, regional volume of distribution (V(T)) values were highest in the pons, thalamus, and cerebellum (1.7-2.7 ml/cm(3)) and lowest in cortical areas (∼0.8 ml/cm(3)). V(T) values were reduced to a homogeneous level following administration of 175 mg bitopertin. Occupancy values derived by a two-tissue five-parameter (2T5P) model, a simplified reference tissue model (SRTM), and a pseudoreference tissue model (PRTM) were overall comparable. At steady state, the relationship between bitopertin plasma concentration and GlyT1 occupancy derived by the 2T5P model, SRTM, and PRTM exhibited an EC(50) of ∼190, ∼200, and ∼130 ng/ml, respectively. E(max) was ∼92% independently of the model used. Bitopertin plasma concentration was a reliable predictor of occupancy because the concentration-occupancy relationship was superimposable at steady state and 2 days after drug discontinuation. These data allow understanding of the concentration-occupancy-efficacy relationship of bitopertin and support dose selection of future molecules.

  13. Determination of left ventricular mass in man using single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Wolfe, C.L.; Jansen, D.E.; Corbett, J.R.; Willerson, J.T.; Lipscomb, K.; Redish, G.; Filipchuk, N.; Gabliani, G.; Lewis, S.E.

    1984-01-01

    The measurement of viable left ventricular (LV) mass may have important prognostic significance in patients with ischemic heart disease or hypertrophic heart disease. To test the hypothesis that single photon emission computed tomography (SPECT) could accurately determine LV mass in man, the authors compared SPECT measurements of LV mass to LV mas determined by cineangiography in 12 patients with normal coronary arteries and normal LV functions. Repeat SPECT determinations of LV mass were carried out in 5 patients. Each patient was injected with 2 to 2.4 mCi of thallium (T1)-201 in the resting state. Projection images (64x64) containing a minimum of 80,000 counts were acquired at 6-degree intervals over 180-degrees using a rotating gamma camera. Transverse sections were reconstructed by filtered backprojection. The boundary of LV uptake of T1-201 in each transverse section was defined using a simple three-dimensional threshold detector. The total number of voxels demonstrating LV T1-201 uptake was multiplied by the voxel volume and the specific gravity of myocardium (1.05g/cc). Cath determinations of LV mass were made from end diastolic frames of a biplane left ventriculogram using the method of a previous study. There was good correlation between LV mass determined by SPECT and by cineangiography. Mean cath LV mass was 207.8 +- 45.4g (S.D.). Mean SPECT LV mass was 207.4 +- 43.3 g. Linear regression analysis revealed the following relationship: SPECT LV mass = 0.78 x Cath LV mass +45.8 (r=0.82, root mean square deviation from regression = 25.1). The SPECT values of LV mass varied an average of 10.4+- 4.6 (S.D.) % in the 5 patients where two determinations were made. The authors conclude that SPECT of T1-201 can accurately measure left ventricular mass in man.

  14. Localized fetomaternal hyperglycemia: spatial and kinetic definition by positron emission tomography.

    Directory of Open Access Journals (Sweden)

    Jianrong Yao

    2010-08-01

    Full Text Available Complex but common maternal diseases such as diabetes and obesity contribute to adverse fetal outcomes. Understanding of the mechanisms involved is hampered by difficulty in isolating individual elements of complex maternal states in vivo. We approached this problem in the context of maternal diabetes and sought an approach to expose the developing fetus in vivo to isolated hyperglycemia in the pregnant rat.We hypothesized that glucose infused into the arterial supply of one uterine horn would more highly expose fetuses in the ipsilateral versus contralateral uterine horn. To test this, the glucose tracer [18F]fluorodeoxyglucose (FDG was infused via the left uterine artery. Regional glucose uptake into maternal tissues and fetuses was quantified using positron emission tomography (PET. Upon infusion, FDG accumulation began in the left-sided placentae, subsequently spreading to the fetuses. Over two hours after completion of the infusion, FDG accumulation was significantly greater in left compared to right uterine horn fetuses, favoring the left by 1.9+/-0.1 and 2.8+/-0.3 fold under fasted and hyperinsulinemic conditions (p<10(-11 n=32-35 and p<10(-12 n=27-45 respectively. By contrast, centrally administered [3H]-2-deoxyglucose accumulated equally between the fetuses of the two uterine horns. Induction of significant hyperglycemia (10(3 mg/dL localized to the left uterine artery was sustained for at least 48 hours while maternal euglycemia was maintained.This approach exposes selected fetuses to localized hyperglycemia in vivo, minimizing exposure of the mother and thus secondary effects. Additionally, a set of less exposed internal control fetuses are maintained for comparison, allowing direct study of the in vivo fetal effects of isolated hyperglycemia. Broadly, this approach can be extended to study a variety of maternal-sided perturbations suspected to directly affect fetal health.

  15. Quantification of regional myocardial oxygenation by magnetic resonance imaging: validation with positron emission tomography.

    Science.gov (United States)

    McCommis, Kyle S; Goldstein, Thomas A; Abendschein, Dana R; Herrero, Pilar; Misselwitz, Bernd; Gropler, Robert J; Zheng, Jie

    2010-01-01

    A comprehensive evaluation of myocardial ischemia requires measures of both oxygen supply and demand. Positron emission tomography (PET) is currently the gold standard for such evaluations, but its use is limited because of its ionizing radiation, limited availability, and high cost. A cardiac MRI method was developed for assessing myocardial oxygenation. The purpose of this study was to evaluate and validate this technique compared with PET during pharmacological stress in a canine model of coronary artery stenosis. Twenty-one beagles and small mongrel dogs without coronary artery stenosis (controls) or with moderate to severe acute coronary artery stenosis underwent MRI and PET imaging at rest and during dipyridamole vasodilation or dobutamine stress to induce a wide range of changes in cardiac perfusion and oxygenation. MRI first-pass perfusion imaging was performed to quantify myocardial blood flow and volume. The MRI blood oxygen level-dependent technique was used to determine the myocardial oxygen extraction fraction during pharmacological hyperemia. Myocardial oxygen consumption was determined by the Fick law. In the same dogs, (15)O-water and (11)C-acetate were used to measure myocardial blood flow and myocardial oxygen consumption, respectively, by PET. Regional assessments were performed for both MR and PET. MRI data correlated nicely with PET values for myocardial blood flow (R(2)=0.79, P<0.001), myocardial oxygen consumption (R(2)=0.74, P<0.001), and oxygen extraction fraction (R(2)=0.66, P<0.01). Cardiac MRI methods may provide an alternative to radionuclide imaging in settings of myocardial ischemia. Our newly developed quantitative MRI oxygenation imaging technique may be a valuable noninvasive tool to directly evaluate myocardial energetics and efficiency.

  16. Noninvasive quantification of muscarinic receptors in vivo with positron emission tomography in the dog heart

    Energy Technology Data Exchange (ETDEWEB)

    Delforge, J.; Janier, M.; Syrota, A.; Crouzel, C.; Vallois, J.M.; Cayla, J.; Lancon, J.P.; Mazoyer, B.M. (Commission a l' Energie Atomique, Orsay (France))

    1990-10-01

    The in vivo quantification of myocardial muscarinic receptors has been obtained in six closed-chest dogs by using positron emission tomography. The dogs were injected with a trace amount of 11C-labeled methylquinuclidinyl benzilate (MQNB), a nonmetabolized antagonist of the muscarinic receptor. This was followed 30 minutes later by an injection of an excess of unlabeled MQNB (displacement experiment). Two additional injections of unlabeled MQNB with (11C)MQNB and without (11C)MQNB (second displacement experiment) were administered after 70 and 120 minutes, respectively. This protocol allowed a separate evaluation of the quantity of available receptors (B'max) as well as the association and dissociation rate constants (k+1 and k-1) in each dog. The parameters were calculated by using a nonlinear mathematical model in regions of interest over the left ventricle and the interventricular septum. The average value of B'max was 42 +/- 11 pmol/ml tissue, the rate constants k+1, k-1, and Kd were 0.6 +/- 0.1 ml.pmol-1.min-1, 0.27 +/- 0.03 ml.pmol-1.min-1, and 0.49 +/- 0.14 pmol.ml-1, respectively, taking into account the MQNB reaction volume estimated to 0.15 ml/ml tissue. Although (11C)MQNB binding would appear irreversible, our findings indicate that the association of the antagonist is very rapid and that the dissociation is far from negligible. The dissociated ligand, however, has a high probability of rebinding to a free receptor site instead of escaping into the microcirculation. We deduce that the positron emission tomographic images obtained after injecting a trace amount of (11C)MQNB are more representative of blood flow than of receptor density or affinity. We also suggest a simplified protocol consisting of a tracer injection of (11C)MQNB and a second injection of an excess of cold MQNB, which is sufficient to measure B'max and Kd in humans.

  17. Dose absorbed by technologists in positron emission tomography procedures with FDG

    Directory of Open Access Journals (Sweden)

    Ademir Amaral

    2007-09-01

    Full Text Available The objective of this work was to evaluate radiation doses delivered to technologists engaged in different tasks involving positron emission tomography (PET studies with FDG (fluorodeoxyglucose. This investigation was performed in two French nuclear medicine departments, which presented significant differences in their arrangements and radiation safety conditions. Both centers administered about 300 MBq per PET/CT study, although only one of them is a dedicated clinical PET center. Dose equivalent Hp(10 and skin dose Hp(0.07 were measured using Siemens electronic personnel dosimeters. For assessment dose absorbed by hands during drawing up of tracer and injection into the patient, a Polimaster wristwatch gamma dosimeter was employed. Absorbed dose and the time spent during each investigated task were recorded for a total of 180 whole-body PET studies. In this report, the methodology employed, the results and their radioprotection issues are presented as well as discussed.O objetivo deste trabalho foi o de avaliar doses absorvidas por profissionais de saúde em diferentes tarefas relacionadas à tomografia por emissão de pósitrons com [18F]-FDG (fluordesoxiglicose. Esta pesquisa foi realizada em dois centros de medicina nuclear na França, os quais apresentavam diferenças significativas em sua organização e radioproteção. Esses centros aplicavam aproximadamente 300 MBq por exame PET/CT, embora apenas um deles correspondesse a um serviço de medicina nuclear dedicado a exames por PET. A dose equivalente (Hp(10 e a dose na pele Hp(0,07 foram medidas usando dosímetros eletrônicos (Siemens. Para avaliação da dose nas mãos do tecnologista durante a preparação do radiofármaco e durante injeção no paciente, um dosímetro tipo relógio de pulso (Polimaster foi empregado. A dose absorvida e o tempo empregado durante cada tarefa foram registrados para um total de 180 exames de corpo inteiro através da PET. Neste trabalho, a metodologia

  18. Use of fluorine-18 fluorodeoxyglucose positron emission tomography in the detection of silent metastases from malignant melanoma

    DEFF Research Database (Denmark)

    Jakobsen, Annika Loft; Andersson, A P; Dahlstrøm, K

    2000-01-01

    Correct staging is crucial for the management and prognosis of patients with malignant melanoma. The aim of this prospective study was to compare staging by whole-body positron emission tomography using fluorine-18 fluorodeoxyglucose (18F-FDG) with staging by conventional methods. Thirty-eight pa......Correct staging is crucial for the management and prognosis of patients with malignant melanoma. The aim of this prospective study was to compare staging by whole-body positron emission tomography using fluorine-18 fluorodeoxyglucose (18F-FDG) with staging by conventional methods. Thirty......-eight patients with malignant melanoma of clinical stage II (local recurrence, in-transit and regional lymph node metastases) or III (metastases to other sites than in stage II) were included in the study. The results of the PET scans were compared with those obtained by clinical examination, computed tomography...... method superior to conventional methods for detecting widespread metastases from malignant melanoma. Mutilating surgery of no benefit can thereby be avoided. 18F-FDG PET is useful as a supplement to clinical examination in melanoma staging....

  19. 18F-Fluorodeoxyglucose Positron Emission Tomography/Magnetic Resonance in Lymphoma

    Science.gov (United States)

    Giraudo, Chiara; Raderer, Markus; Karanikas, Georgios; Weber, Michael; Kiesewetter, Barbara; Dolak, Werner; Simonitsch-Klupp, Ingrid; Mayerhoefer, Marius E.

    2016-01-01

    Objectives The aim of this study was to compare 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/magnetic resonance (MR) (with and without diffusion-weighted imaging [DWI]) to 18F-FDG PET/computed tomography (CT), with regard to the assessment of nodal and extranodal involvement, in patients with Hodgkin lymphoma and non-Hodgkin lymphoma, without restriction to FDG-avid subytpes. Materials and Methods Patients with histologically proven lymphoma were enrolled in this prospective, institutional review board–approved study. After a single 18F-FDG injection, patients consecutively underwent 18F-FDG PET⁄CT and 18F-FDG PET/MR on the same day for staging or restaging. Three sets of images were analyzed separately: 18F-FDG PET/CT, 18F-FDG PET/MR without DWI, and 18F-FDG PET/MR with DWI. Region-based agreement and examination-based sensitivity and specificity were calculated for 18F-FDG PET/CT, 18F-FDG PET/MR without DWI, and 18F-FDG PET/MR DWI. Maximum and mean standardized uptake values (SUVmax, SUVmean) on 18F-FDG PET/CT and 18F-FDG PET/MR were compared and correlated with minimum and mean apparent diffusion coefficients (ADCmin, ADCmean). Results Thirty-four patients with a total of 40 examinations were included. Examination-based sensitivities for 18F-FDG PET/CT, 18F-FDG PET/MR, and 18F-FDG PET/MR DWI were 82.1%, 85.7%, and 100%, respectively; specificities were 100% for all 3 techniques; and accuracies were 87.5%, 90%, and 100%, respectively. 18F-FDG PET/CT was false negative in 5 of 40 examinations (all with mucosa-associated lymphoid tissue lymphoma), and 18F-FDG PET/MR (without DWI) was false negative in 4 of 40 examinations. Region-based percentages of agreement were 99% (κ, 0.95) between 18F-FDG PET/MR DWI and 18F-FDG PET/CT, 99.2% (κ, 0.96) between 18F-FDG PET/MR and 18F-FDG PET/CT, and 99.4% (κ, 0.97) between 18F-FDG PET/MR DWI and 18F-FDG PET/MR. There was a strong correlation between 18F-FDG PET/CT and 18F-FDG PET/MR for SUVmax (r = 0

  20. Single photon emission computed tomography using sup 99 Tc sup m -HMPAO in Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Liu, H.-C.; Liu, R.-S.; Lin, K.-N.; Wang, S.-J.; Fuh, J.-L.; Yeh, S.-H.; Chiang, B.N. (Veterans General Hospital, Taipei, Taiwan (China))

    1992-07-01

    Brain single photon emission computed tomography (SPET) using {sup 99m}Tc{sup m}-hexamethylpropyleneamine oxime (HMPAO) was performed in 37 patients satisfying standard clinical criteria of Alzheimer's disease (AD), correlating results with patient's age of onset, duration of illness, severity of dementia, neuropsychological impairment, computed tomography (CT) and EEG findings. All had abnormal SPET: 23 were bilaterally symmetric, 10 bilaterally asymmetric and four showed unilateral low regional cerebral perfusion. Low perfusion in bilateral parietal regions was the most consistent finding and was present alone or with other abnormal regions in 31 patients (84%). The only significant clinical correlation was found between asymmetric SPECT changes and onset of disease before the age of 65 years. 50% of patients with presenile onset, but only 19% with senile onset had asymmetric low regional cerebral perfusion. Fifteen of the 36 patients had normal brain CT scans, and 9 of 31 patients receiving EEG examination had normal results. (author).

  1. Imaging atherosclerosis with hybrid [18F]fluorodeoxyglucose positron emission tomography/computed tomography imaging: what Leonardo da Vinci could not see.

    Science.gov (United States)

    Cocker, Myra S; Mc Ardle, Brian; Spence, J David; Lum, Cheemun; Hammond, Robert R; Ongaro, Deidre C; McDonald, Matthew A; Dekemp, Robert A; Tardif, Jean-Claude; Beanlands, Rob S B

    2012-12-01

    Prodigious efforts and landmark discoveries have led toward significant advances in our understanding of atherosclerosis. Despite significant efforts, atherosclerosis continues globally to be a leading cause of mortality and reduced quality of life. With surges in the prevalence of obesity and diabetes, atherosclerosis is expected to have an even more pronounced impact upon the global burden of disease. It is imperative to develop strategies for the early detection of disease. Positron emission tomography (PET) imaging utilizing [(18)F]fluorodeoxyglucose (FDG) may provide a non-invasive means of characterizing inflammatory activity within atherosclerotic plaque, thus serving as a surrogate biomarker for detecting vulnerable plaque. The aim of this review is to explore the rationale for performing FDG imaging, provide an overview into the mechanism of action, and summarize findings from the early application of FDG PET imaging in the clinical setting to evaluate vascular disease. Alternative imaging biomarkers and approaches are briefly discussed.

  2. The Correlation Between Pre-treatment Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Parameters and Clinical Prognostic Factors in Pediatric Hodgkin Lymphoma

    Directory of Open Access Journals (Sweden)

    Ebru Tatcı

    2017-02-01

    Full Text Available Objective: To compare standardized uptake values (SUV derived from pre-treatment 18F-fluorodeoxyglucose (FDG positron emission tomography/computed tomography (PET/CT imaging and clinical prognostic factors in pediatric patients with Hodgkin lymphoma (HL. Methods: Pre-treatment FDG PET/CT findings of 28 children with HL were evaluated in this retrospective study. Metabolic tumor volume (MTV, SUVmax normalized by weight (SUVweight, lean body mass (SUVlbm, body surface area (SUVbsa and plasma glucose levels of tumors (SUVglucose were calculated using pre-treatment FDG PET/CT scan images. These metabolic parameters were correlated with clinical factors [age, sex, number of lymph node groups, presence of splenic involvement, bulky mediastinal disease, Ann Arbor stage, serum white blood cell (WBC count, erythrocyte sedimentation rate (ESR, serum albumin and hemoglobin levels]. Results: SUVbsa, SUVlbm, SUVweight, SUVglucose and MTV were higher in patients with stage III-IV disease, bulky tumor and ≥3 lymph node groups (p0.05. SUVbsa and SUVlbm were higher in patients with anemia (p0.05. Conclusion: Metabolic parameters derived from pre-treatment FDG PET/CT may have an important role in predicting high-risk disease in patients with HL. Also, SUVbsa and SUVlbm may be better markers than SUVweight in the quantitative evaluation of FDG PET/CT scans in pediatric patients.

  3. Therapeutic impact of [{sup 18}F]fluoride positron-emission tomography/computed tomography on patients with unclear foot pain

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Dorothee Rita; Hesselmann, Rolf; Johayem, Anass; Hany, Thomas F.; Schulthess, Gustav K. von; Strobel, Klaus [University Hospital of Zurich, Department of Nuclear Medicine, Zurich (Switzerland); Maquieira, Gerardo J.; Espinosa, Norman [University of Zurich, Foot and Ankle Surgery, Department of Orthopaedics, Zurich (Switzerland); Zanetti, Marco [University of Zurich, Department of Radiology, Zurich (Switzerland)

    2010-10-15

    To evaluate the therapeutic impact of [{sup 18}F]fluoride positron-emission tomography/computed tomography ([{sup 18}F]fluoride PET/CT) imaging on patients with unclear foot pain. Twenty-eight patients were prospectively included in this study. Therapeutic management was defined by two experienced dedicated foot surgeons before and after [{sup 18}F]fluoride PET/CT imaging. Twenty-six patients underwent cross-sectional imaging [CT, magnetic resonance (MR)] prior to PET/CT. A retrospective analysis of the magnetic resonance imaging (MRI) diagnoses was performed when a therapy change occurred after PET/CT imaging. In 13/28 (46%) patients therapeutic management was changed due to PET/CT results. Management changes occurred in patients with the following diagnoses: os trigonum syndrome; sinus tarsi syndrome; os tibiale externum syndrome; osteoarthritis of several joints; non-consolidated fragments; calcaneo-navicular coalition; plantar fasciitis; insertional tendinopathy; suggestion of periostitis; neoarticulations between metatarsal bones. Os trigonum, os tibiale externum, subtalar osteoarthritis and plantar fasciitis were only seen to be active on PET/CT images but not on MR images. [{sup 18}F]fluoride PET/CT has a substantial therapeutic impact on management in patients with unclear foot pain. (orig.)

  4. Positron emission tomography-computer tomography scan used as a monitoring tool following cellular therapy in cerebral palsy and mental retardation-a case report.

    Science.gov (United States)

    Sharma, Alok; Sane, Hemangi; Paranjape, Amruta; Gokulchandran, Nandini; Kulkarni, Pooja; Nagrajan, Anjana; Badhe, Prerna

    2013-01-01

    Cerebral palsy (CP) is one of the non-progressive neurological diseases caused by damage to the brain tissue at birth, which leads to physical, cognitive and perceptive symptoms. Even after lifelong medical and therapeutic management there are residual deficits which affect the quality of life of the patients and their families. We examined a maximally rehabilitated, 20 year old male suffering from CP and Mental Retardation (MR). He had diplegic gait and Intelligence Quotient (IQ) score of 44 with affected fine motor activities, balance, speech and higher functions. Positron Emission Tomography-Computer Tomography (PET-CT) scan identified frontal, temporal, parietal, occipital, left cerebellar lobes, amygdala, hippocampus, and parahippocampus as the affected areas. He was treated with cellular therapy of Autologous Bone Marrow Derived Mono-Nuclear Cells (MNCs) transplantation followed by multidisciplinary rehabilitation. Six months following therapy, PET-CT scan showed significant increase in metabolic activity in all four lobes, mesial temporal structures and left cerebellar hemisphere, also supported by clinical improvement in IQ, social behavior, speech, balance and daily functioning. These findings provide preliminary evidence to support the efficacy of cellular therapy for the treatment of CP with MR. PET-CT scan can also be viewed as an impressive tool to monitor the effects of cellular therapy.

  5. Head sinuses, melon, and jaws of bottlenose dolphins, Tursiops truncatus, observed with computed tomography structural and single photon emission computed tomography functional imaging

    Science.gov (United States)

    Ridgway, Sam; Houser, Dorian; Finneran, James J.; Carder, Don; van Bonn, William; Smith, Cynthia; Hoh, Carl; Corbeil, Jacqueline; Mattrey, Robert

    2003-04-01

    The head sinuses, melon, and lower jaws of dolphins have been studied extensively with various methods including radiography, chemical analysis, and imaging of dead specimens. Here we report the first structural and functional imaging of live dolphins. Two animals were imaged, one male and one female. Computed tomography (CT) revealed extensive air cavities posterior and medial to the ear as well as between the ear and sound-producing nasal structures. Single photon emission computed tomography (SPECT) employing 50 mCi of the intravenously injected ligand technetium [Tc-99m] biscisate (Neurolite) revealed extensive and uptake in the core of the melon as well as near the pan bone area of the lower jaw. Count density on SPECT images was four times greater in melon as in the surrounding tissue and blubber layer suggesting that the melon is an active rather than a passive tissue. Since the dolphin temporal bone is not attached to the skull except by fibrous suspensions, the air cavities medial and posterior to the ear as well as the abutment of the temporal bone, to the acoustic fat bodies of each lower jaw, should be considered in modeling the mechanism of sound transmission from the environment to the dolphin ear.

  6. Influence of the Pixel Sizes of Reference Computed Tomography on Single-photon Emission Computed Tomography Image Reconstruction Using Conjugate-gradient Algorithm.

    Science.gov (United States)

    Okuda, Kyohei; Sakimoto, Shota; Fujii, Susumu; Ida, Tomonobu; Moriyama, Shigeru

    The frame-of-reference using computed-tomography (CT) coordinate system on single-photon emission computed tomography (SPECT) reconstruction is one of the advanced characteristics of the xSPECT reconstruction system. The aim of this study was to reveal the influence of the high-resolution frame-of-reference on the xSPECT reconstruction. 99mTc line-source phantom and National Electrical Manufacturers Association (NEMA) image quality phantom were scanned using the SPECT/CT system. xSPECT reconstructions were performed with the reference CT images in different sizes of the display field-of-view (DFOV) and pixel. The pixel sizes of the reconstructed xSPECT images were close to 2.4 mm, which is acquired as originally projection data, even if the reference CT resolution was varied. The full width at half maximum (FWHM) of the line-source, absolute recovery coefficient, and background variability of image quality phantom were independent on the sizes of DFOV in the reference CT images. The results of this study revealed that the image quality of the reconstructed xSPECT images is not influenced by the resolution of frame-of-reference on SPECT reconstruction.

  7. Reduced ventilation-perfusion (V/Q) mismatch following endobronchial valve insertion demonstrated by Gallium-68 V/Q photon emission tomography/computed tomography.

    Science.gov (United States)

    Leong, Paul; Le Roux, Pierre-Yves; Callahan, Jason; Siva, Shankar; Hofman, Michael S; Steinfort, Daniel P

    2017-09-01

    Endobronchial valves (EBVs) are increasingly deployed in the management of severe emphysema. Initial studies focussed on volume reduction as the mechanism, with subsequent improvement in forced expiratory volume in 1 s (FEV1). More recent studies have emphasized importance of perfusion on predicting outcomes, though findings have been inconsistent. Gallium-68 ventilation-perfusion (V/Q) photon emission tomography (PET)/computed tomography (CT) is a novel imaging modality with advantages in spatial resolution, quantitation, and speed over conventional V/Q scintigraphy. We report a pilot case in which V/Q-PET/CT demonstrated discordant findings compared with quantitative CT analysis, and directed left lower lobe EBV placement. The patient experienced a significant improvement in 6-min walk distance (6MWD) without change in spirometry. Post-EBV V/Q-PET/CT demonstrated a marked decrease in unmatched (detrimental) V/Q areas and improvement in overall V/Q matching on post-EBV V/Q-PET/CT. These preliminary novel findings suggest that EBVs improve V/Q matching and may explain the observed functional improvements.

  8. Prognostic impact of myocardial perfusion single photon emission computed tomography in patients with major extracardiac findings by computed tomography for attenuation correction.

    Science.gov (United States)

    Zadro, Charline; Roussel, Noé; Cassol, Emmanuelle; Pascal, Pierre; Petermann, Antoine; Meyrignac, Olivier; Jaffro, Marion; Fournier, Pauline; Cournot, Maxime; Galinier, Michel; Carrié, Didier; Rousseau, Hervé; Berry, Isabelle; Lairez, Olivier

    2017-03-09

    Attenuation correction computed tomography (CT) contributes to an improvement in the diagnostic accuracy of myocardial perfusion imaging (MPI) by single photon emission tomography (SPECT). The aim of this study was to explore the prognosis of patients with major findings by CT according to the results of MPI. 1506 patients who underwent MPI by SPECT were retrospectively included. Attenuation correction CT images were systematically analyzed for major and minor abnormalities. 830 (55.1%) and 212 (14.1%) patients had minor and major extracardiac findings, respectively. Among patients with major extracardiac findings, the abnormality was previously unknown in 113 (53.3%) patients. 90 (41.9%) had abnormal MPI, 73 (34.4%) had a myocardial infarction scar, 55 (25.9%) had myocardial ischemia, and 38 (17.7%) patients had both myocardial infarction scar and myocardial ischemia. Among the 201 patients available for survival analysis, there were 67 (31.2%) deaths over a follow-up period of 3.2±1.3 years. There was no significant impact on survival arising from MPI, whatever the result. The results were the same among the 103 patients with previously unknown major extracardiac findings. Extracardiac findings by CT during MPI are frequent. Patients with major extracardiac findings have a poor mid-term outcome, whatever the results of the myocardial perfusion imaging. Extracardiac findings should be systematically checked when attenuation correction CT is performed.

  9. Endogenous endophthalmitis caused by Cryptococcus neoformans Var. Gattii mimicking choroidal tumor: From positron-emission tomography/computed tomography to histopathology

    Directory of Open Access Journals (Sweden)

    Chun-Ju Lin

    2017-01-01

    Full Text Available A 60-year-old immunocompetent female with pneumonia history about 10 years ago suffered from blurred vision overall survival for 3 weeks. Common cold with headache and unintentional body weight loss was also noted recently. Choroidal detachment simulating choroidal tumor was observed in the temporal quadrant. The 18F-fluoro-2-deoxyglucose (FDG positron-emission tomography/computed tomography (CT scan showed focal, mild to moderate FDG uptake in the left lateral orbit, and an enhanced lesion was seen on the recent CT scan. The suspicious choroidal tumor became larger in a week. Phacoemulsification, vitrectomy, and retinal biopsies were performed. Histochemical study of the retinal specimens established the diagnosis of endogenous cryptococcal endophthalmitis. Vitreous culture yielded Cryptococcus neoformans var. gattii. Systemic and topical voriconazole eliminated the infection. In the literature, endogenous endophthalmitis caused by C. neoformans var. gattii has not been reported in detail. The key to successful management lies in early diagnosis. If clinical improvement could not be achieved after conventional management and imaging studies have failed to yield a definite diagnosis, retinal biopsy can be considered.

  10. Lymphadenopathy resulting from acute toxoplasmosis mimicking relapse of non-Hodgkin′s lymphoma on fluorodeoxyglucose positron emission tomography/computed tomography

    Directory of Open Access Journals (Sweden)

    Prathamesh Joshi

    2012-01-01

    Full Text Available We report a case documenting fluorodeoxyglucose (FDG accumulation in cervical, supraclavicular and axillary lymph nodes resulting from acute toxoplasmosis. A 50-year-old Indian female with history of non-Hodgkin′s lymphoma (NHL of left breast, postchemotherapy status, was found to have hypermetabolic right cervical, supraclavicular and axillary lymph nodes on a surveillance FDG positron emission tomography/computed tomography (PET/CT scan. Her previous two PET/CT scans were unremarkable with no evidence of metabolically active disease. Therefore, a differential diagnosis of relapse of NHL versus infectious/inflammatory pathology was raised in the report. Biopsy of axillary lymph node demonstrated features characteristic of toxoplasmosis. The serological test results were also compatible with acute toxoplasmosis infection. Infective and inflammatory diseases are known to accumulate FDG, resulting in false positives for malignancy. This case demonstrates lymph nodal toxoplasmosis as a potential cause of false positive FDG PET/CT findings in patients with known malignancy and highlights the importance of histopathological and laboratory correlation for the accurate interpretation of FDG PET/CT scans.

  11. Superiority of Deformable Image Co-registration in the Integration of Diagnostic Positron Emission Tomography-Computed Tomography to the Radiotherapy Treatment Planning Pathway for Oesophageal Carcinoma.

    Science.gov (United States)

    Ward, G; Ramasamy, S; Sykes, J R; Prestwich, R; Chowdhury, F; Scarsbrook, A; Murray, P; Harris, K; Crellin, A; Hatfield, P; Sebag-Montefiore, D; Spezi, E; Crosby, T; Radhakrishna, G

    2016-10-01

    To investigate the use of image co-registration in incorporating diagnostic positron emission tomography-computed tomography (PET-CT) directly into the radiotherapy treatment planning pathway, and to describe the pattern of local recurrence relative to the PET-avid volume. Fourteen patients were retrospectively identified, six of whom had local recurrence. The accuracy of deformable image registration (DIR) and rigid registration of the diagnostic PET-CT and recurrence CT, to the planning CT, were quantitatively assessed by comparing co-registration of oesophagus, trachea and aorta contours. DIR was used to examine the correlation between PET-avid volumes, dosimetry and site of recurrence. Positional metrics including the dice similarity coefficient (DSC) and conformity index (CI), showed DIR to be superior to rigid registration in the co-registration of diagnostic and recurrence imaging to the planning CT. For diagnostic PET-CT, DIR was superior to rigid registration in the transfer of oesophagus (DSC=0.75 versus 0.65, Pimaging, DIR was superior to rigid registration in the transfer of trachea (DSC=0.91 versus 0.66, Pregistration in the co-registration of PET-CT and recurrence CT to the planning CT, and can be considered in the direct integration of PET-CT to the treatment planning process. Local recurrences occur within the PTVPET-CT, suggesting that this is a suitable target for dose-escalation strategies. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  12. Disease activity and 18F-FDG uptake in organising pneumonia: semi-quantitative evaluation using computed tomography and positron emission tomography.

    Science.gov (United States)

    Tateishi, Ukihide; Hasegawa, Tadashi; Seki, Kunihiko; Terauchi, Takashi; Moriyama, Noriyuki; Arai, Yasuaki

    2006-08-01

    The present study was conducted to evaluate whether( 18)F-fluorodeoxyglucose positron emission tomography (FDG-PET) in combination with computed tomography (CT) reflects disease activity in patients with organising pneumonia. Eighty-eight subjects who were normal (n=66) or who had proven organising pneumonia (n=22) underwent FDG-PET and CT imaging. The subjects included 55 men and 33 women, ranging in age from 24 to 63 years (mean 47 years). PET and CT data sets were digitally fused using a conformational PET/CT fusion algorithm. All scans were evaluated independently by two chest radiologists who were unaware of other clinical data. The visual score, maximal and mean standardised uptake value (SUV), and maximal and mean lesion-to-normal tissue ratio (LNR) were calculated. The imaging results were compared with the laboratory and pulmonary function test results. The inflammatory cells in the lesions were quantified immunohistochemically. The visual score, maximal and mean SUV, and maximal and mean LNR of the patients with organising pneumonia were significantly higher than those of the normal subjects. The patients with air-space consolidation had a significantly higher SUV than those without air-space consolidation (mean+/-SD 3.08+/-0.39 vs 2.35+/-0.56; porganising pneumonia have an enhanced FDG accumulation which reflects the degree of disease activity.

  13. Effect of furosemide administration before F-18 fluorodeoxyglucose positron emission tomography/computed tomography on urine radioactivity and detection of uterine cervical cancer.

    Science.gov (United States)

    d'Amico, Andrea; Gorczewska, Izabela; Gorczewski, Kamil; Turska-d'Amico, Maria; Di Pietro, Marco

    2014-01-01

    In evaluating uterine cervical cancer with ¹⁸F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT), there may be overlap between the FDG activity at tumor sites and nonspecific radioactivity in the urine. We evaluated the efficacy of furosemide premedication with routine hydration to obtain better contrast and less overlap between cervical cancer and the urinary bladder. We retrospectively evaluated 166 patients who had primary or relapsed cervical cancer and underwent FDG PET/CT scanning with (133 patients) or without (33 patients) furosemide premedication (10 mg intravenous, slowly injected 30 min before the scan). We calculated bladder and tumor maximum and median standardized uptake value (SUVmax and SUVmed), and overlap between tumor and urinary activity was detected visually. Overlap between urinary and tumor radioactivity was observed in 8 of 133 scans (6%) in patients who receive furosemide and in 3 of 33 scans (9%) in patients who did not receive furosemide. The SUVmax and SUVmed for the bladder were significantly lower in patients who were pretreated with furosemide (SUVmax, 6.3; SUVmed, 4.6) than patients who were not pretreated with furosemide (SUVmax, 8.8 [P ≤ 0.008]; SUVmed, 6.5 [P ≤ 0.002]). The tumor SUVmax and SUVmed were similar between the patient groups. Furosemide premedication before FDG PET/CT scanning may enable improved evaluation of activity and extension of cervical cancer.

  14. Clinical effectiveness of (18)f-fluorodeoxyglucose positron emission tomography/computed tomography in management of renal cell carcinoma: a single institution experience.

    Science.gov (United States)

    Win, Aung Zaw; Aparici, Carina Mari

    2015-01-01

    Positron emission tomography (PET) is currently the most advanced technique of metabolic imaging available for tumor diagnosis and follow-up. The aim of this study was to examine the versatility and accuracy of fluorodeoxyglucose (FDG) PET/computed tomography (CT) in the metastasis detection of renal cell carcinoma (RCC). We also compared our findings to other similar studies from the literature. This is the biggest study so far to examine the sensitivity and specificity of FDG PET/CT in the management of RCC. A retrospective review was carried out on all the FDG PET/CT studies done from January 1999 to January 2014 at our institution. Biopsy results were considered the gold standard. For our patients (n = 315) with biopsy results, FDG PET/CT studies exhibited 100% sensitivity, 100% specificity. Our results were better than results achieved by other studies. The use of FDG PET/CT in restaging and metastasis detection of RCC has many advantages, in addition to high accuracy. This imaging technique has great potential in influencing treatment decisions. We recommend the incorporation of FDG PET/CT in routine standard protocols for RCC.

  15. Clinical Effectiveness of 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in Management of Renal Cell Carcinoma: A Single Institution Experience

    Science.gov (United States)

    Win, Aung Zaw; Aparici, Carina Mari

    2015-01-01

    Positron emission tomography (PET) is currently the most advanced technique of metabolic imaging available for tumor diagnosis and follow-up. The aim of this study was to examine the versatility and accuracy of fluorodeoxyglucose (FDG) PET/computed tomography (CT) in the metastasis detection of renal cell carcinoma (RCC). We also compared our findings to other similar studies from the literature. This is the biggest study so far to examine the sensitivity and specificity of FDG PET/CT in the management of RCC. A retrospective review was carried out on all the FDG PET/CT studies done from January 1999 to January 2014 at our institution. Biopsy results were considered the gold standard. For our patients (n = 315) with biopsy results, FDG PET/CT studies exhibited 100% sensitivity, 100% specificity. Our results were better than results achieved by other studies. The use of FDG PET/CT in restaging and metastasis detection of RCC has many advantages, in addition to high accuracy. This imaging technique has great potential in influencing treatment decisions. We recommend the incorporation of FDG PET/CT in routine standard protocols for RCC. PMID:25709543

  16. F-8 sodium fluoride position emission tomography/computed tomography for detection of thyroid cancer bone metastasis compared with bone scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyun Jong; Lee, Won Woo; Park, So Yeon; Kim, Sang Eun [Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2016-04-15

    The aim of the study was to compare the diagnostic performances of F-18 sodium fluoride positron emission tomography/computed tomography (bone PET/CT) and bone scintigraphy (BS) for the detection of thyroid cancer bone metastasis. We retrospectively enrolled 6 thyroid cancer patients (age = 44.7 ± 9.8 years, M:F = 1:5, papillary:follicular = 2:4) with suspected bone metastatic lesions in the whole body iodine scintigraphy or BS, who subsequently underwent bone PET/CT. Pathologic diagnosis was conducted for 4 lesions of 4 patients. Of the 17 suspected bone lesions, 10 were metastatic and 7 benign. Compared to BS, bone PET/CT exhibited superior sensitivity (10/10 = 100% vs. 2/10 = 20%, p = 0.008), and accuracy (14/17 = 82.4% vs. 7/17 = 41.2%, p < 0.025). The specificity (4/7 = 57.1%) of bone PET/CT was not significantly different from that of BS (5/7 = 71.4%, p > 0.05). Bone PET/CT may be more sensitive and accurate than BS for the detection of thyroid cancer bone metastasis.

  17. The potential of positron emission tomography/computerized tomography (PET/CT) scanning as a detector of high-risk patients with oral infection during preoperative staging.

    Science.gov (United States)

    Yamashiro, Keisuke; Nakano, Makoto; Sawaki, Koichi; Okazaki, Fumihiko; Hirata, Yasuhisa; Takashiba, Shogo

    2016-08-01

    It is sometimes difficult to determine during the preoperative period whether patients have oral infections; these patients need treatment to prevent oral infection-related complications from arising during medical therapies, such as cancer therapy and surgery. One of the reasons for this difficulty is that basic medical tests do not identify oral infections, including periodontitis and periapical periodontitis. In this report, we investigated the potential of positron emission tomography/computerized tomography (PET/CT) as a diagnostic tool in these patients. We evaluated eight patients during the preoperative period. All patients underwent PET/CT scanning and were identified as having the signs of oral infection, as evidenced by (18)F-fludeoxyglucose (FDG) localization in the oral regions. Periodontal examination and orthopantomogram evaluation showed severe infection or bone resorption in the oral regions. (18)F-FDG was localized in oral lesions, such as severe periodontitis, apical periodontitis, and pericoronitis of the third molar. The densities of (18)F-FDG were proportional to the degree of inflammation. PET/CT is a potential diagnostic tool for oral infections. It may be particularly useful in patients during preoperative staging, as they frequently undergo scanning at this time, and those identified as having oral infections at this time require treatment before cancer therapy or surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. [11C]-(R)-PK11195 positron emission tomography in patients with complex regional pain syndrome

    Science.gov (United States)

    Jeon, So Yeon; Seo, Seongho; Lee, Jae Sung; Choi, Soo-Hee; Lee, Do-Hyeong; Jung, Ye-Ha; Song, Man-Kyu; Lee, Kyung-Jun; Kim, Yong Chul; Kwon, Hyun Woo; Im, Hyung-Jun; Lee, Dong Soo; Cheon, Gi Jeong; Kang, Do-Hyung

    2017-01-01

    Abstract Complex regional pain syndrome (CRPS) is characterized by severe and chronic pain, but the pathophysiology of this disease are not clearly understood. The primary aim of our case–control study was to explore neuroinflammation in patients with CRPS using positron emission tomography (PET), with an 18-kDa translocator protein specific radioligand [11C]-(R)-PK11195. [11C]-(R)-PK11195 PET scans were acquired for 11 patients with CRPS (30–55 years) and 12 control subjects (30–52 years). Parametric image of distribution volume ratio (DVR) for each participant was generated by applying a relative equilibrium-based graphical analysis. The DVR of [11C]-(R)-PK11195 in the caudate nucleus (t(21) = −3.209, P = 0.004), putamen (t(21) = −2.492, P = 0.022), nucleus accumbens (t(21) = −2.218, P = 0.040), and thalamus (t(21) = −2.395, P = 0.026) were significantly higher in CRPS patients than in healthy controls. Those of globus pallidus (t(21) = −2.045, P = 0.054) tended to be higher in CRPS patients than in healthy controls. In patients with CRPS, there was a positive correlation between the DVR of [11C]-(R)-PK11195 in the caudate nucleus and the pain score, the visual analog scale (r = 0.661, P = 0.026, R2 = 0.408) and affective subscales of McGill Pain Questionnaire (r = 0.604, P = 0.049, R2 = 0.364). We demonstrated that neuroinflammation of CRPS patients in basal ganglia. Our results suggest that microglial pathology can be an important pathophysiology of CRPS. Association between the level of caudate nucleus and pain severity indicated that neuroinflammation in this region might play a key role. These results may be essential for developing effective medical treatments. PMID:28072713

  19. Simplifications in analyzing positron emission tomography data: effects on outcome measures

    Energy Technology Data Exchange (ETDEWEB)

    Logan, Jean [Medical Department, Brookhaven National Laboratory, Upton, NY 11973 (United States)], E-mail: logan@bnl.gov; Alexoff, David; Kriplani, Aarti [Medical Department, Brookhaven National Laboratory, Upton, NY 11973 (United States)

    2007-10-15

    Initial validation studies of new radiotracers generally involve kinetic models that require a measured arterial input function. This allows for the separation of tissue binding from delivery and blood flow effects. However, when using a tracer in a clinical setting, it is necessary to eliminate arterial blood sampling due to its invasiveness and the extra burden of counting and analyzing the blood samples for metabolites. In some cases, it may also be necessary to replace dynamic scanning with a shortened scanning period some time after tracer injection, as is done with FDG (F-18 fluorodeoxyglucose). These approximations represent loss of information. In this work, we considered several questions related to this: (1) Do differences in experimental conditions (drug treatments) or populations affect the input function, and what effect, if any, does this have on the final outcome measure? (2) How do errors in metabolite measurements enter into results? (3) What errors are incurred if the uptake ratio is used in place of the distribution volume ratio? (4) Is one- or two-point blood sampling any better for FDG data than the standardized uptake value? and (5) If blood sampling is necessary, what alternatives are there to arterial blood sampling? The first three questions were considered in terms of data from human dynamic positron emission tomography (PET) studies under conditions of baseline and drug pretreatment. Data from [{sup 11}C]raclopride studies and those from the norepinephrine transporter tracer (S,S)-[{sup 11}C]O-methyl reboxetine were used. Calculation of a metabolic rate for FDG using the operational equation requires a measured input function. We tested a procedure based on two blood samples to estimate the plasma integral and convolution that occur in the operational equation. There are some tracers for which blood sampling is necessary. Strategies for brain studies involve using the internal carotids in estimating the radioactivity after correcting for

  20. Optimal transformations leading to normal distributions of positron emission tomography standardized uptake values

    Science.gov (United States)

    Scarpelli, Matthew; Eickhoff, Jens; Cuna, Enrique; Perlman, Scott; Jeraj, Robert

    2018-02-01

    The statistical analysis of positron emission tomography (PET) standardized uptake value (SUV) measurements is challenging due to the skewed nature of SUV distributions. This limits utilization of powerful parametric statistical models for analyzing SUV measurements. An ad-hoc approach, which is frequently used in practice, is to blindly use a log transformation, which may or may not result in normal SUV distributions. This study sought to identify optimal transformations leading to normally distributed PET SUVs extracted from tumors and assess the effects of therapy on the optimal transformations. Methods. The optimal transformation for producing normal distributions of tumor SUVs was identified by iterating the Box–Cox transformation parameter (λ) and selecting the parameter that maximized the Shapiro–Wilk P-value. Optimal transformations were identified for tumor SUVmax distributions at both pre and post treatment. This study included 57 patients that underwent 18F-fluorodeoxyglucose (18F-FDG) PET scans (publically available dataset). In addition, to test the generality of our transformation methodology, we included analysis of 27 patients that underwent 18F-Fluorothymidine (18F-FLT) PET scans at our institution. Results. After applying the optimal Box–Cox transformations, neither the pre nor the post treatment 18F-FDG SUV distributions deviated significantly from normality (P  >  0.10). Similar results were found for 18F-FLT PET SUV distributions (P  >  0.10). For both 18F-FDG and 18F-FLT SUV distributions, the skewness and kurtosis increased from pre to post treatment, leading to a decrease in the optimal Box–Cox transformation parameter from pre to post treatment. There were types of distributions encountered for both 18F-FDG and 18F-FLT where a log transformation was not optimal for providing normal SUV distributions. Conclusion. Optimization of the Box–Cox transformation, offers a solution for identifying normal SUV

  1. Characteristics of Smoothing Filters to Achieve the Guideline Recommended Positron Emission Tomography Image without Harmonization

    Directory of Open Access Journals (Sweden)

    Yuji Tsutsui

    2018-01-01

    Full Text Available Objective(s: The aim of this study is to examine the effect of different smoothing filters on the image quality and SUVmax to achieve the guideline recommended positron emission tomography (PET image without harmonization. Methods: We used a Biograph mCT PET scanner. A National Electrical Manufacturers Association (NEMA the International Electrotechnical Commission (IEC body phantom was filled with 18F solution with a background activity of 2.65 kBq/mL and a sphere-to-background ratio of 4. PET images obtained with the Biograph mCT PET scanner were reconstructed using the ordered subsets-expectation maximization (OSEM algorithm with time-of-flight (TOF models (iteration, 2; subset, 21; smoothing filters including the Gaussian, Butterworth, Hamming, Hann, Parzen, and Shepp-Logan filters with various full width at half maximum (FWHM values (1-15 mm were applied. The image quality was physically assessed according to the percent contrast (QH,10, background variability (N10, standardized uptake value (SUV, and recovery coefficient (RC. The results were compared with the guideline recommended range proposed by the Japanese Society of Nuclear Medicine and the Japanese Society of Nuclear Medicine Technology. The PET digital phantom was developed from the digital reference object (DRO of the NEMA IEC body phantom smoothed using a Gaussian filter with a 10-mm FWHM and defined as the reference image. The difference in the SUV between the PET image and the reference image was evaluated according to the root mean squared error (RMSE. Results: The FWHMs of the Gaussian, Butterworth, Hamming, Hann, Parzen, and Shepp-Logan filters that satisfied the image quality of the FDG-PET/CT standardization guideline criteria were 8-12 mm, 9-11 mm, 9-13 mm, 10-13 mm, 9-11 mm, and 12- 15 mm, respectively. The FWHMs of the Gaussian, Butterworth, Hamming, Hann, Parzen, and Shepp-Logan filters that provided the smallest RMSE between the PET images and the 3D digital phantom

  2. In-vivo detection of the erythropoietin receptor in tumours using positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Fuge, Felix; Doleschel, Dennis; Rix, Anne; Gremse, Felix; Lederle, Wiltrud; Kiessling, Fabian [RWTH Aachen University, Department for Experimental Molecular Imaging (ExMI), Medical Faculty, Aachen (Germany); Wessner, Axel [Roche Diagnostics GmbH, R and D RPD Protein Chemistry, Penzberg (Germany); Winz, Oliver; Mottaghy, Felix [University Clinic RWTH Aachen, Clinic for Nuclear Medicine, Aachen (Germany)

    2014-09-09

    Recombinant human erythropoietin (rhuEpo) is used clinically to treat anaemia. However, rhuEpo-treated cancer patients show decreased survival rates and erythropoietin receptor (EpoR) expression has been found in patient tumour tissue. Thus, rhuEpo application might promote EpoR{sup +} tumour progression. We therefore developed the positron emission tomography (PET)-probe {sup 68}Ga-DOTA-rhuEpo and evaluated its performance in EpoR{sup +} A549 non-small-cell lung cancer (NSCLC) xenografts. {sup 68}Ga-DOTA-rhuEpo was generated by coupling DOTA-hydrazide to carbohydrate side-chains of rhuEpo. Biodistribution was determined in tumour-bearing mice 0.5, 3, 6, and 9 h after probe injection. Competition experiments were performed by co-injecting {sup 68}Ga-DOTA-rhuEpo and rhuEpo in five-fold excess. Probe specificity was further evaluated histologically using Epo-Cy5.5 stainings. The blood half-life of {sup 68}Ga-DOTA-rhuEpo was 2.6 h and the unbound fraction was cleared by the liver and kidney. After 6 h, the highest tumour to muscle ratio was reached. The highest {sup 68}Ga-DOTA-rhuEpo accumulation was found in liver (10.06 ± 6.26%ID/ml), followed by bone marrow (1.87 ± 0.53%ID/ml), kidney (1.58 ± 0.39 %ID/ml), and tumour (0.99 ± 0.16%ID/ml). EpoR presence in these organs was histologically confirmed. Competition experiments showed significantly (p < 0.05) lower PET-signals in tumour and bone marrow at 3 and 6 h. {sup 68}Ga-DOTA-rhuEpo shows favourable pharmacokinetic properties and detects EpoR specifically. Therefore, it might become a valuable radiotracer to monitor EpoR status in tumours and support decision-making in anaemia therapy. (orig.)

  3. Radiolabeling human peripheral blood stem cells for positron emission tomography (PET imaging in young rhesus monkeys.

    Directory of Open Access Journals (Sweden)

    Alice F Tarantal

    Full Text Available These studies focused on a new radiolabeling technique with copper ((64Cu and zirconium ((89Zr for positron emission tomography (PET imaging using a CD45 antibody. Synthesis of (64Cu-CD45 and (89Zr-CD45 immunoconjugates was performed and the evaluation of the potential toxicity of radiolabeling human peripheral blood stem cells (hPBSC was assessed in vitro (viability, population doubling times, colony forming units. hPBSC viability was maintained as the dose of (64Cu-TETA-CD45 increased from 0 (92% to 160 µCi/mL (76%, p>0.05. Radiolabeling efficiency was not significantly increased with concentrations of (64Cu-TETA-CD45 >20 µCi/mL (p>0.50. Toxicity affecting both growth and colony formation was observed with hPBSC radiolabeled with ≥40 µCi/mL (p0.05, and a trend towards increased radiolabeling efficiency was noted as the dose of (89Zr-Df-CD45 increased, with a greater level of radiolabeling with 160 µCi/mL compared to 0-40 µCi/mL (p<0.05. A greater than 2,000 fold-increase in the level of (89Zr-Df-CD45 labeling efficiency was observed when compared to (64Cu-TETA-CD45. Similar to (64Cu-TETA-CD45, toxicity was noted when hPBSC were radiolabeled with ≥40 µCi/mL (p<0.05 (growth, colony formation. Taken together, 20 µCi/mL resulted in the highest level of radiolabeling efficiency without altering cell function. Young rhesus monkeys that had been transplanted prenatally with 25×10(6 hPBSC expressing firefly luciferase were assessed with bioluminescence imaging (BLI, then 0.3 mCi of (89Zr-Df-CD45, which showed the best radiolabeling efficiency, was injected intravenously for PET imaging. Results suggest that (89Zr-Df-CD45 was able to identify engrafted hPBSC in the same locations identified by BLI, although the background was high.

  4. Development of a prototype Open-close positron emission tomography system

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Seiichi, E-mail: s-yama@met.nagoya-u.ac.jp; Okumura, Satoshi; Komori, Masataka; Ogata, Yoshimune; Kato, Katsuhiko [Department of Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Nagoya (Japan); Watabe, Tadashi; Ikeda, Hayato; Kanai, Yasukazu [Department of Molecular Imaging in Medicine, Osaka University Graduate School of Medicine, Osaka (Japan); Toshito, Toshiyuki [Department of Proton Therapy Physics, Nagoya Proton Therapy Center, Nagoya City West Medical Center, Nagoya (Japan); Hatazawa, Jun [Department of Molecular Imaging in Medicine, Osaka University Graduate School of Medicine, Osaka (Japan); Department of Nuclear Medicine and Tracer Kinetics, Osaka University Graduate School of Medicine, Osaka (Japan)

    2015-08-15

    We developed a prototype positron emission tomography (PET) system based on a new concept called Open-close PET, which has two modes: open and close-modes. In the open-mode, the detector ring is separated into two halved rings and subject is imaged with the open space and projection image is formed. In the close-mode, the detector ring is closed to be a regular circular ring, and the subject can be imaged without an open space, and so reconstructed images can be made without artifacts. The block detector of the Open-close PET system consists of two scintillator blocks that use two types of gadolinium orthosilicate (GSO) scintillators with different decay times, angled optical fiber-based image guides, and a flat panel photomultiplier tube. The GSO pixel size was 1.6 × 2.4 × 7 mm and 8 mm for fast (35 ns) and slow (60 ns) GSOs, respectively. These GSOs were arranged into an 11 × 15 matrix and optically coupled in the depth direction to form a depth-of-interaction detector. The angled optical fiber-based image guides were used to arrange the two scintillator blocks at 22.5° so that they can be arranged in a hexadecagonal shape with eight block detectors to simplify the reconstruction algorithm. The detector ring was divided into two halves to realize the open-mode and set on a mechanical stand with which the distance between the two parts can be manually changed. The spatial resolution in the close-mode was 2.4-mm FWHM, and the sensitivity was 1.7% at the center of the field-of-view. In both the close- and open-modes, we made sagittal (y-z plane) projection images between the two halved detector rings. We obtained reconstructed and projection images of {sup 18}F-NaF rat studies and proton-irradiated phantom images. These results indicate that our developed Open-close PET is useful for some applications such as proton therapy as well as other applications such as molecular imaging.

  5. Transfer of learning with an application to the physics of positron emission tomography

    Science.gov (United States)

    Aryal, Bijaya

    2007-12-01

    A series of teaching activities using physical models was developed to present some portions of physics of Positron Emission Tomography (PET) and investigate students' understanding and transfer of learning in physics to a medical technology. A teaching interview protocol consistent with a qualitative research methodology was developed and administered to the students enrolled in an algebra-based introductory level physics course. 16 students participated in individual interviews and another 21 students participated in the group sessions. The major objectives of the teaching interviews were to investigate students' transfer of physics learning from their prior experiences to the provided physical models, from one model to the other and from the models to the PET problems. The study adapted phenomenological research methodology in analyzing students' use of cognitive resources and cognitive strategies during knowledge construction and reconstruction. A resource based transfer model framed under the cognitive theory of learning and consistent with contemporary views of transfer was used to describe the transfer of physics learning. Results of the study indicated both appropriate and inappropriate use of the students' prior conceptual resources in novel contexts. Scaffolding and questioning were found to be effective in activating appropriate and suppressing the inappropriate resources. The physical models used as analogies were found useful in transferring physics learning to understand image construction in PET. Positive transfer was possible when the models were introduced in an appropriate sequence. The results of the study indicate the occurrence of three types of non-scaffolded transfer---spontaneous, semi spontaneous and non-spontaneous. The research found connections between sequencing of hints and phrasing of information in activating students' different conceptual resources. A qualitative investigation based on Vygotsky's Zone of Proximal Development (ZPD

  6. A Sub-Sampling Approach for Data Acquisition in Gamma Ray Emission Tomography

    Science.gov (United States)

    Fysikopoulos, Eleftherios; Kopsinis, Yannis; Georgiou, Maria; Loudos, George

    2016-06-01

    State of the art data acquisition systems for small animal imaging gamma ray detectors often rely on free running Analog to Digital Converters (ADCs) and high density Field Programmable Gate Arrays (FPGA) devices for digital signal processing. In this work, a sub-sampling acquisition approach, which exploits a priori information regarding the shape of the obtained detector pulses is proposed. Output pulses shape depends on the response of the scintillation crystal, photodetector's properties and amplifier/shaper operation. Using these known characteristics of the detector pulses prior to digitization, one can model the voltage pulse derived from the shaper (a low-pass filter, last in the front-end electronics chain), in order to reduce the desirable sampling rate of ADCs. Fitting with a small number of measurements, pulse shape estimation is then feasible. In particular, the proposed sub-sampling acquisition approach relies on a bi-exponential modeling of the pulse shape. We show that the properties of the pulse that are relevant for Single Photon Emission Computed Tomography (SPECT) event detection (i.e., position and energy) can be calculated by collecting just a small fraction of the number of samples usually collected in data acquisition systems used so far. Compared to the standard digitization process, the proposed sub-sampling approach allows the use of free running ADCs with sampling rate reduced by a factor of 5. Two small detectors consisting of Cerium doped Gadolinium Aluminum Gallium Garnet (Gd3Al2Ga3O12 : Ce or GAGG:Ce) pixelated arrays (array elements: 2 × 2 × 5 mm3 and 1 × 1 × 10 mm3 respectively) coupled to a Position Sensitive Photomultiplier Tube (PSPMT) were used for experimental evaluation. The two detectors were used to obtain raw images and energy histograms under 140 keV and 661.7 keV irradiation respectively. The sub-sampling acquisition technique (10 MHz sampling rate) was compared with a standard acquisition method (52 MHz sampling

  7. Measurement of acetylcholinesterase (AChE) activity in living brain by positron emission tomography (PET)

    Energy Technology Data Exchange (ETDEWEB)

    Irie, Toshiaki [National Inst. of Radiological Sciences, Chiba (Japan)

    1999-07-01

    Central cholinergic neuronal system has been known to be related to learning and memory, and its deficit is found in the brain of Alzheimer's disease (AD) and other degenerative disorders. Postmortem studies have shown that acetylcholinesterase (AChE), one of biochemical markers of central cholinergic nerve system, is consistently reduced in the cerebral cortex of patients with Alzheimer's disease (AD). Non-invasive mapping and/or measuring AChE activity in the living brain by positron emission tomography (PET) would be a useful tool for assessment of cholinergic dysfunction in AD and other disorders, and provide a direct method for validation of therapeutic efficacy of drugs, AChE inhibitors. We have challenged to measure AChE activity using tracers of substrate type, radiolabelled acetylcholine analogs, which are lipophilic enough to go across blood brain barrier and are metabolically trapped by AChE in the brain. The analogs designed, N-methylpiperidyl esters, were evaluated in terms of their metabolic rate and specificity against AChE. Studies examining the response to AChE activity showed metabolic accumulation of some analogs responded well to changes in cortical AChE activity in an animal model of AD. The study was further applied to living human by PET using [{sup 11}C]N-methylpiperidyl-4-acetate (MP4A), which was chosen on the basis of its reactivity and specificity suitable for the human cortical AChE. Regional cerebral metabolic rate of MP4A reflecting AChE activity was quantitatively determined using three compartment model analysis of dynamic PET data and the arterial input function obtained by TLC-radioluminography or plasma samples. The kinetic analyses showed that AChE activities estimated were well agree with those of postmortem examination in cerebral cortices and thalamus in healthy subjects, and that there was significant reduction of cortical AChE activity in patients with AD. The results suggest feasibility of the present method for

  8. Cerebral Hypoperfusion in Hereditary Coproporphyria (HCP): A Single Photon Emission Computed Tomography (SPECT) Study

    Science.gov (United States)

    Valle, Guido; Guida, Claudio Carmine; Nasuto, Michelangelo; Totaro, Manuela; Aucella, Filippo; Frusciante, Vincenzo; Di Mauro, Lazzaro; Potenza, Adele; Savino, Maria; Stanislao, Mario; Popolizio, Teresa; Guglielmi, Giuseppe; Giagulli, Vito Angelo; Guastamacchia, Edoardo; Triggiani, Vincenzo

    2016-01-01

    Background: Hereditary Coproporphyria (HCP) is characterized by abdominal pain, neurologic symptoms and psychiatric disorders, even if it might remain asymptomatic. The pathophysiology of both neurologic and psychiatric symptoms is not fully understood. Therefore, aiming to evaluate a possible role of brain blood flow disorders, we have retrospectively investigated cerebral perfusion patterns in Single Photon Emission Computed Tomography (SPECT) studies in HCP patients. Materials & Methods: We retrospectively evaluated the medical records of patients diagnosed as being affected by HCP. A total of seven HCP patients had been submitted to brain perfusion SPECT study with 99mTc-Exametazime (hexamethylpropyleneamine oxime, HMPAO) or with its functionally equivalent 99mTc-Bicisate (ECD or Neurolite) according with common procedures. In 3 patients the scintigraphic study had been repeated for a second time after the first evaluation at 3, 10 and 20 months, respectively. All the studied subjects had been also submitted to an electromyographic and a Magnetic Resonance Imaging (MRI) study of the brain. Results: Mild to moderate perfusion defects were detected in temporal lobes (all 7 patients), frontal lobes (6 patients) and parietal lobes (4 patients). Occipital lobe, basal ganglia and cerebellar involvement were never observed. In the three subjects in which SPECT study was repeated, some recovery of hypo-perfused areas and appearance of new perfusion defects in other brain regions have been found. In all patients electromyography resulted normal and MRI detected few unspecific gliotic lesions only in one patient. Discussion & Conclusions: Since perfusion abnormalities were usually mild to moderate, this can probably explain the normal pattern observed at MRI studies. Compared to MRI, SPECT with 99mTc showed higher sensitivity in HCP patients. Changes observed in HCP patients who had more than one study suggest that transient perfusion defects might be due to a brain

  9. Brain Perfusion Single Photon Emission Computed Tomography Abnormalities in Patients with Minimal Hepatic Encephalopathy

    Science.gov (United States)

    Sunil, Hejjaji Venkataramarao; Mittal, Bhagwant Rai; Kurmi, Roshan; Chawla, Yogesh K; Dhiman, Radha K

    2012-01-01

    Background Minimal hepatic encephalopathy (MHE) is the mildest form of hepatic encephalopathy (HE). Minimal hepatic encephalopathy patients do not demonstrate clinically overt symptoms of HE but present with abnormal neuropsychological and/or neurophysiological tests indicative of cerebral dysfunction. This study was performed in such patients to identify regions of abnormal cerebral perfusion and to correlate regional cerebral blood flow (rCBF) changes with psychometric hepatic encephalopathy score (PHES), Child-Turcotte-Pugh's score (CTP), and model for end-stage liver disease (MELD) score. We also compared abnormal patterns of rCBF in cirrhotic patients of alcoholic etiology with non-alcoholic etiology. Methods This prospective study was performed to evaluate rCBF in 50 cirrhotic patients and 13 controls using technetium-99m ethyl cysteinate dimer (Tc-99m ECD) brain single photon emission computed tomography. All the patients underwent a battery of psychometry tests, PHES. Minimal hepatic encephalopathy was diagnosed if PHES was ≤−5. The rCBF changes were evaluated using region of interest (ROI) based semi-quantitative method of region/cerebellum and region/cortex ratios in 16 regions of the brain. Results Cirrhotic patients with MHE showed impaired perfusion in the superior prefrontal cortex and increased perfusion in the thalamus, brain-stem, medial temporal cortex, and the hippocampus when compared with the controls. Cerebral perfusion in superior prefrontal cortex correlated negatively with MELD score (r=−0.323, P=0.022). We found significant positive correlation between PHES score and rCBF values in the left superior prefrontal cortex (r=0.385, P=0.006). Cirrhotic patients with alcohol etiology showed significantly decreased rCBF in right inferior prefrontal cortex, right superior prefrontal cortex, and the anterior cingulate cortex while increased rCBF was noted in the right medial temporal cortex and hippocampus. Conclusion Our results suggest that

  10. Development of Traceable Phantoms for Improved Image Quantification in Positron Emission Tomography

    Science.gov (United States)

    Zimmerman, Brian

    2014-03-01

    Clinical trials for new drugs increasingly rely on imaging data to monitor patient response to the therapy being studied. In the case of radiopharmaceutical applications, imaging data are also used to estimate organ and tumor doses in order to arrive at the optimal dosage for safe and effective treatment. Positron Emission Tomography (PET) is one of the most commonly used imaging modalities for these types of applications. In large, multicenter trials it is crucial to minimize as much as possible the variability that arises due to use of different types of scanners and other instrumentation so that the biological response can be more readily evaluated. This can be achieved by ensuring that all the instruments are calibrated to a common standard and that their performance is continuously monitored throughout the trial. Maintaining links to a single standard also enables the comparability of data acquired on a heterogeneous collection of instruments in different clinical settings. As the standards laboratory for the United States, the National Institute of Standards and Technology (NIST) has been developing a suite of phantoms having traceable activity content to enable scanner calibration and performance testing. The configurations range from small solid cylindrical sources having volumes from 1 mL to 23 mL to large cylinders having a total volume of 9 L. The phantoms are constructed with 68Ge as a long-lived substitute for the more clinically useful radionuclide 18F. The contained activity values are traceable to the national standard for 68Ge and are also linked to the standard for 18F through a careful series of comparisons. The techniques that have been developed are being applied to a variety of new phantom configurations using different radionuclides. Image-based additive manufacturing techniques are also being investigated to create fillable phantoms having irregular shapes which can better mimic actual organs and tumors while still maintaining traceability

  11. Multimodality Imaging Probe for Positron Emission Tomography and Fluorescence Imaging Studies

    Directory of Open Access Journals (Sweden)

    Suresh K. Pandey

    2014-05-01

    Full Text Available Our goal is to develop multimodality imaging agents for use in cell tracking studies by positron emission tomography (PET and optical imaging (OI. For this purpose, bovine serum albumin (BSA was complexed with biotin (histologic studies, 5(6- carboxyfluorescein, succinimidyl ester (FAM SE (OI studies, and diethylenetriamine pentaacetic acid (DTPA for chelating gallium 68 (PET studies. For synthesis of BSA-biotin-FAM-DTPA, BSA was coupled to (+-biotin N-hydroxysuccinimide ester (biotin-NHSI. BSA- biotin was treated with DTPA-anhydride and biotin-BSA-DTPA was reacted with FAM. The biotin-BSA-DTPA-FAM was reacted with gallium chloride 3 to 5 mCi eluted from the generator using 0.1 N HCl and was passed through basic resin (AG 11 A8 and 150 mCi (100 μL, pH 7–8 was incubated with 0.1 mg of FAM conjugate (100 μL at room temperature for 15 minutes to give 66Ga-BSA-biotin-DTPA-FAM. A shaved C57 black mouse was injected with FAM conjugate (50 μL at one flank and FAM-68Ga (50 μL, 30 mCi at the other. Immediately after injection, the mouse was placed in a fluorescence imaging system (Kodak In-Vivo F, Bruker Biospin Co., Woodbridge, CT and imaged (Λex: 465 nm, Λem: 535 nm, time: 8 seconds, Xenon Light Source, Kodak. The same mouse was then placed under an Inveon microPET scanner (Siemens Medical Solutions, Knoxville, TN injected (intravenously with 25 μCi of 18F and after a half-hour (to allow sufficient bone uptake was imaged for 30 minutes. Molecular weight determined using matrix-associated laser desorption ionization (MALDI for the BSA sample was 66,485 Da and for biotin-BSA was 67,116 Da, indicating two biotin moieties per BSA molecule; for biotin-BSA-DTPA was 81,584 Da, indicating an average of 30 DTPA moieties per BSA molecule; and for FAM conjugate was 82,383 Da, indicating an average of 1.7 fluorescent moieties per BSA molecule. Fluorescence imaging clearly showed localization of FAM conjugate and FAM-68Ga at respective flanks of the mouse

  12. Development of a prototype Open-close positron emission tomography system

    Science.gov (United States)

    Yamamoto, Seiichi; Okumura, Satoshi; Watabe, Tadashi; Ikeda, Hayato; Kanai, Yasukazu; Toshito, Toshiyuki; Komori, Masataka; Ogata, Yoshimune; Kato, Katsuhiko; Hatazawa, Jun

    2015-08-01

    We developed a prototype positron emission tomography (PET) system based on a new concept called Open-close PET, which has two modes: open and close-modes. In the open-mode, the detector ring is separated into two halved rings and subject is imaged with the open space and projection image is formed. In the close-mode, the detector ring is closed to be a regular circular ring, and the subject can be imaged without an open space, and so reconstructed images can be made without artifacts. The block detector of the Open-close PET system consists of two scintillator blocks that use two types of gadolinium orthosilicate (GSO) scintillators with different decay times, angled optical fiber-based image guides, and a flat panel photomultiplier tube. The GSO pixel size was 1.6 × 2.4 × 7 mm and 8 mm for fast (35 ns) and slow (60 ns) GSOs, respectively. These GSOs were arranged into an 11 × 15 matrix and optically coupled in the depth direction to form a depth-of-interaction detector. The angled optical fiber-based image