WorldWideScience

Sample records for emission computed tomography

  1. Emission computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.

    1986-01-01

    Emission Computed Tomography is a technique used for producing single or multiple cross-sectional images of the distribution of radionuclide labelled agents in vivo. The techniques of Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are described with particular regard to the function of the detectors used to produce images and the computer techniques used to build up images. (UK)

  2. Emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Gullberg, G.T.; Huesman, R.H.

    1979-01-01

    This chapter is devoted to the methods of computer assisted tomography for determination of the three-dimensional distribution of gamma-emitting radionuclides in the human body. The major applications of emission computed tomography are in biological research and medical diagnostic procedures. The objectives of these procedures are to make quantitative measurements of in vivo biochemical and hemodynamic functions

  3. Positron emission computed tomography

    International Nuclear Information System (INIS)

    Grover, M.; Schelbert, H.R.

    1985-01-01

    Regional mycardial blood flow and substrate metabolism can be non-invasively evaluated and quantified with positron emission computed tomography (Positron-CT). Tracers of exogenous glucose utilization and fatty acid metabolism are available and have been extensively tested. Specific tracer kinetic models have been developed or are being tested so that glucose and fatty acid metabolism can be measured quantitatively by Positron-CT. Tracers of amino acid and oxygen metabolism are utilized in Positron-CT studies of the brain and development of such tracers for cardiac studies are in progress. Methods to quantify regional myocardial blood flow are also being developed. Previous studies have demonstrated the ability of Positron-/CT to document myocardial infarction. Experimental and clinical studies have begun to identify metabolic markers of reversibly ischemic myocardium. The potential of Positron-CT to reliably detect potentially salvageable myocardium and, hence, to identify appropriate therapeutic interventions is one of the most exciting applications of the technique

  4. Emission computed tomography

    International Nuclear Information System (INIS)

    Phelps, M.E.

    1977-01-01

    Although there are many common aspects to x-ray transmission and radionuclide emission (ECT) computerized tomography, there are added difficulties and a number of particular factors which form the basis of ECT. The relationship between the physical factors, system design, methodologic approach and assumptions of ECT is discussed. The instrumentation design and application strategies in ECT at this time are diverse and in a rapid stage of development. The approaches are divided into two major categories of Single Photon Counting (SPC) employing scanner and camera concepts with radionuclides of 99 /sup m/Tc, 201 Tl, 123 I etc., and Annihilation Coincidence Detection (ACD) of positron-emitting radionuclides. Six systems in the former and ten systems in the latter category, with examples of typical studies, illustrate the different approaches

  5. An introduction to emission computed tomography

    International Nuclear Information System (INIS)

    Williams, E.D.

    1985-01-01

    This report includes salient features of the theory and an examination of practical considerations for someone who is using or introducing tomography, selecting equipment for it or wishing to develop a clinical application. Emphasis is on gamma camera tomography. The subject is dealt with under the following headings: emission computed and gamma camera tomography and the relationship to other medical imaging techniques, the tomographic reconstruction technique theory, rotating gamma camera tomography, attenuation correction and quantitative reconstruction, other single photon tomographic techniques, positron tomography, image display, clinical application of single photon and positron tomography, and commercial systems for SPECT. Substantial bibliography. (U.K.)

  6. Development of emission computed tomography in Japan

    International Nuclear Information System (INIS)

    Tanaka, E.

    1984-01-01

    Two positron emission computed tomography (PCT) devices developed in Japan are described. One is for head and the other for wholebody. The devices show fairly quantitative images with slight modifications of the existing algorithms because they were developed based on filtered back-projection. The PCT device seems to be better than the single photon emission computed tomography (SPECT) since it provides adequade compensation for photon attenuation in patients. (M.A.C.) [pt

  7. Measuring techniques in emission computed tomography

    International Nuclear Information System (INIS)

    Jordan, K.; Knoop, B.

    1988-01-01

    The chapter reviews the historical development of the emission computed tomography and its basic principles, proceeds to SPECT and PET, special techniques of emission tomography, and concludes with a comprehensive discussion of the mathematical fundamentals of the reconstruction and the quantitative activity determination in vivo, dealing with radon transformation and the projection slice theorem, methods of image reconstruction such as analytical and algebraic methods, limiting conditions in real systems such as limited number of measured data, noise enhancement, absorption, stray radiation, and random coincidence. (orig./HP) With 111 figs., 6 tabs [de

  8. Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography in Disseminated Cryptococcosis.

    Science.gov (United States)

    Tripathy, Sarthak; Parida, Girish Kumar; Roy, Shambo Guha; Singhal, Abhinav; Mallick, Saumya Ranjan; Tripathi, Madhavi; Shamim, Shamim Ahmed

    2017-01-01

    Disseminated cryptococcosis without pulmonary involvement is a very rare phenomenon. Patterns of organ involvement in cryptococcosis resemble various other infective conditions as well as malignant conditions on fluorodeoxyglucose positron emission tomography-computed tomography. We present a case of a 43-year-old male patient who had disseminated cryptococcosis. The rarity of the case being noninvolvement of lungs and meninges and resembling more like lymphoma due to the diffuse involvement of the lymph nodes on both sides of the diaphragm.

  9. 21 CFR 892.1200 - Emission computed tomography system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Emission computed tomography system. 892.1200... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1200 Emission computed tomography system. (a) Identification. An emission computed tomography system is a device intended to detect the...

  10. Emission computed tomography: methodology and applications

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.; Greenberg, J.; Fowler, J.; Christman, D.; Rosenquist, A.; Rintelmann, W.; Hand, P.; MacGregor, R.; Wolf, A.

    1980-01-01

    A technique for the determination of local cerebral glucose metabolism using positron emission computed tomography is described as an example of the development of use of this methodology for the study of these parameters in man. The method for the determination of local cerebral glucose metabolism utilizes 18 F-2-fluoro-2-deoxyglucose ([ 18 F]-FDG). In this method [ 18 F]-FDG is used as a tracer for the exchange of glucose between plasma and brain and its phosphorylation by hexokinase in the tissue. The labelled product of metabolism, [ 18 F]-FDG phosphate, is essentially trapped in the tissue over the time course of the measurement. The studies demonstrate the potential usefulness of emission computed tomography for the measurement of various biochemical and physiological parameters in man. (Auth.)

  11. Physics and instrumentation of emission computed tomography

    International Nuclear Information System (INIS)

    Links, J.M.

    1986-01-01

    Transverse emission computed tomography can be divided into two distinct classes: single photon emission computed tomography (SPECT) and positron emission tomography (PET). SPECT is usually accomplished with specially-adapted scintillation cameras, although dedicated SPECT scanners are available. The special SPECT cameras are standard cameras which are mounted on gantries that allow 360 degree rotation around the long axis of the head or body. The camera stops at a number of angles around the body (usually 64-128), acquiring a ''projection'' image at each stop. The data from these projections are used to reconstruct transverse images with a standard ''filtered back-projection'' algorithm, identical to that used in transmission CT. Because the scintillation camera acquires two-dimensional images, a simple 360 degree rotation around the patient results in the acquisition of data for a number of contiguous transverse slices. These slices, once reconstructed, can be ''stacked'' in computer memory, and orthogonal coronal and sagittal slices produced. Additionally, reorienting algorithms allow the generation of slices that are oblique to the long axis of the body

  12. Positron emission tomography/computed tomography scanning for ...

    African Journals Online (AJOL)

    Background: Although the site of nosocomial sepsis in the critically ill ventilated patient is usually identifiable, it may remain occult, despite numerous investigations. The rapid results and precise anatomical location of the septic source using positron emission tomography (PET) scanning, in combination with computed ...

  13. Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Pan, Tinsu; Zaidi, Habib

    2013-01-01

    This article discusses attenuation correction strategies in positron emission tomography/computed tomography (PET/CT) and 4 dimensional PET/CT imaging. Average CT scan derived from averaging the high temporal resolution CT images is effective in improving the registration of the CT and the PET images and quantification of the PET data. It underscores list mode data acquisition in 4 dimensional PET and introduces 4 dimensional CT popular in thoracic treatment planning to 4 dimensional PET/CT. ...

  14. Single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.

    1986-01-01

    Single photon tomography dates from the early 1960's when the idea of emission transverse section tomography was presented by Kuhl and Edwards. They used a rectilinear scanner and analogue back-projection methods to detect emissions from a series of sequential positions transverse to the cephaldcaudad axis of the body. This chapter presents an explanation of emission tomography by describing longitudinal and transverse section tomography. In principle all modes of tomography can be considered under the general topic of coded apertures wherein the code ranges from translation of a pinhole collimator to rotation of a parallel hole or focused collimator array

  15. Electrocardiographic gating in positron emission computed tomography

    International Nuclear Information System (INIS)

    Hoffman, E.J.; Phelps, M.E.; Wisenberg, G.; Schelbert, H.R.; Kuhl, D.E.

    1979-01-01

    Electrocardiographic (ECG) synchronized multiple gated data acquisition was employed with positron emission computed tomography (ECT) to obtain images of myocardial blood pool and myocardium. The feasibility and requirements of multiple gated data acquisition in positron ECT were investigated for 13NH3, ( 18 F)-2-fluoro-2-D-deoxyglucose, and ( 11 C)-carboxyhemoglobin. Examples are shown in which image detail is enhanced and image interpretation is facilitated when ECG gating is employed in the data collection. Analysis of count rate data from a series of volunteers indicates that multiple, statistically adequate images can be obtained under a multiple gated data collection format without an increase in administered dose

  16. Neutron stimulated emission computed tomography: Background corrections

    International Nuclear Information System (INIS)

    Floyd, Carey E.; Sharma, Amy C.; Bender, Janelle E.; Kapadia, Anuj J.; Xia, Jessie Q.; Harrawood, Brian P.; Tourassi, Georgia D.; Lo, Joseph Y.; Kiser, Matthew R.; Crowell, Alexander S.; Pedroni, Ronald S.; Macri, Robert A.; Tajima, Shigeyuki; Howell, Calvin R.

    2007-01-01

    Neutron stimulated emission computed tomography (NSECT) is an imaging technique that provides an in-vivo tomographic spectroscopic image of the distribution of elements in a body. To achieve this, a neutron beam illuminates the body. Nuclei in the body along the path of the beam are stimulated by inelastic scattering of the neutrons in the beam and emit characteristic gamma photons whose unique energy identifies the element. The emitted gammas are collected in a spectrometer and form a projection intensity for each spectral line at the projection orientation of the neutron beam. Rotating and translating either the body or the beam will allow a tomographic projection set to be acquired. Images are reconstructed to represent the spatial distribution of elements in the body. Critical to this process is the appropriate removal of background gamma events from the spectrum. Here we demonstrate the equivalence of two background correction techniques and discuss the appropriate application of each

  17. Positron emission tomography/computed tomography imaging and rheumatoid arthritis.

    Science.gov (United States)

    Wang, Shi-Cun; Xie, Qiang; Lv, Wei-Fu

    2014-03-01

    Rheumatoid arthritis (RA) is a phenotypically heterogeneous, chronic, destructive inflammatory disease of the synovial joints. A number of imaging tools are currently available for evaluation of inflammatory conditions. By targeting the upgraded glucose uptake of infiltrating granulocytes and tissue macrophages, positron emission tomography/computed tomography with fluorine-18 fluorodeoxyglucose ((18) F-FDG PET/CT) is available to delineate inflammation with high sensitivity. Recently, several studies have indicated that FDG uptake in affected joints reflects the disease activity of RA. In addition, usage of FDG PET for the sensitive detection and monitoring of the response to treatment has been reported. Combined FDG PET/CT enables the detailed assessment of disease in large joints throughout the whole body. These unique capabilities of FDG PET/CT imaging are also able to detect RA-complicated diseases. Therefore, PET/CT has become an excellent ancillary tool to assess disease activity and prognosis in RA. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  18. Therapy response evaluation with positron emission tomography-computed tomography.

    Science.gov (United States)

    Segall, George M

    2010-12-01

    Positron emission tomography-computed tomography with F-18-fluorodeoxyglucose is widely used for evaluation of therapy response in patients with solid tumors but has not been as readily adopted in clinical trials because of the variability of acquisition and processing protocols and the absence of universal response criteria. Criteria proposed for clinical trials are difficult to apply in clinical practice, and gestalt impression is probably accurate in individual patients, especially with respect to the presence of progressive disease and complete response. Semiquantitative methods of determining tissue glucose metabolism, such as standard uptake value, can be a useful descriptor for levels of tissue glucose metabolism and changes in response to therapy if technical quality control measures are carefully maintained. The terms partial response, complete response, and progressive disease are best used in clinical trials in which the terms have specific meanings and precise definitions. In clinical practice, it may be better to use descriptive terminology agreed upon by imaging physicians and clinicians in their own practice. Copyright © 2010. Published by Elsevier Inc.

  19. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  20. Hybrid Single Photon Emission Computed Tomography/Computed Tomography Sulphur Colloid Scintigraphy in Focal Nodular Hyperplasia

    International Nuclear Information System (INIS)

    Bhoil, Amit; Gayana, Shankramurthy; Sood, Ashwani; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2013-01-01

    It is important to differentiate focal nodular hyperplasia (FNH), a benign condition of liver most commonly affecting women, from other neoplasm such as hepatic adenoma and metastasis. The functional reticuloendothelial features of FNH can be demonstrated by scintigraphy. We present a case of breast cancer in whom fluorodeoxyglucose positron emission tomography/computerized tomography (CT) showed a homogenous hyperdense lesion in liver, which on Tc99m sulfur colloid single-photon emission computed tomography/CT was found to have increased focal tracer uptake suggestive of FNH

  1. Applications of X-ray Computed Tomography and Emission Computed Tomography

    International Nuclear Information System (INIS)

    Seletchi, Emilia Dana; Sutac, Victor

    2005-01-01

    Computed Tomography is a non-destructive imaging method that allows visualization of internal features within non-transparent objects such as sedimentary rocks. Filtering techniques have been applied to circumvent the artifacts and achieve high-quality images for quantitative analysis. High-resolution X-ray computed tomography (HRXCT) can be used to identify the position of the growth axis in speleothems by detecting subtle changes in calcite density between growth bands. HRXCT imagery reveals the three-dimensional variability of coral banding providing information on coral growth and climate over the past several centuries. The Nuclear Medicine imaging technique uses a radioactive tracer, several radiation detectors, and sophisticated computer technologies to understand the biochemical basis of normal and abnormal functions within the brain. The goal of Emission Computed Tomography (ECT) is to accurately determine the three-dimensional radioactivity distribution resulting from the radiopharmaceutical uptake inside the patient instead of the attenuation coefficient distribution from different tissues as obtained from X-ray Computer Tomography. ECT is a very useful tool for investigating the cognitive functions. Because of the low radiation doses associated with Positron Emission Tomography (PET), this technique has been applied in clinical research, allowing the direct study of human neurological diseases. (authors)

  2. Diagnosis of dementia with single photon emission computed tomography

    International Nuclear Information System (INIS)

    Jagust, W.J.; Budinger, T.F.; Reed, B.R.

    1987-01-01

    Single photon emission computed tomography is a practical modality for the study of physiologic cerebral activity in vivo. We utilized single photon emission computed tomography and N-isopropyl-p-iodoamphetamine iodine 123 to evaluate regional cerebral blood flow in nine patients with Alzheimer's disease (AD), five healthy elderly control subjects, and two patients with multi-infarct dementia. We found that all subjects with AD demonstrated flow deficits in temporoparietal cortex bilaterally, and that the ratio of activity in bilateral temporoparietal cortex to activity in the whole slice allowed the differentiation of all patients with AD from both the controls and from the patients with multi-infarct dementia. Furthermore, this ratio showed a strong correlation with disease severity in the AD group. Single photon emission computed tomography appears to be useful in the differential diagnosis of dementia and reflects clinical features of the disease

  3. Single photon emission computed tomography and oth selected computer topics

    International Nuclear Information System (INIS)

    Frey, G.D.

    1981-01-01

    This book, the proceedings of a meeting in January 1980, contains 21 papers. Thirteen are devoted to aspects of emission tomography, four to nuclear cardiology, and five to other topics. The initial set of papers consists of reviews of the single photon emission tomography process. These include transverse axial tomography using scintillation cameras and other devices, longitudinal section tomography, and pin-hole and slant-hole systems. These reviews are generally well done, but as might be expected, lack any coherence from paper to paper. The papers on nuclear cardiology include several of Fourier analysis in nuclear cardiology and one on shunt quantification. Other clinical papers are on quantifying Tc-99m glucoheptonate uptake in the brain and on iron-59 retention studies. A general criticism of the book is the poor quality of photographic reproductions

  4. Quantification in single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Buvat, Irene

    2005-01-01

    The objective of this lecture is to understand the possibilities and limitations of the quantitative analysis of single photon emission computed tomography (SPECT) images. It is also to identify the conditions to be fulfilled to obtain reliable quantitative measurements from images. Content: 1 - Introduction: Quantification in emission tomography - definition and challenges; quantification biasing phenomena; 2 - quantification in SPECT, problems and correction methods: Attenuation, scattering, un-stationary spatial resolution, partial volume effect, movement, tomographic reconstruction, calibration; 3 - Synthesis: actual quantification accuracy; 4 - Beyond the activity concentration measurement

  5. Single photon emission computed tomography in children with idiopathic seizures

    International Nuclear Information System (INIS)

    Hara, Masafumi; Takahashi, Mutsumasa; Kojima, Akihiro; Shimomura, Osamu; Kinoshita, Rumi; Tomiguchi, Seiji; Taku, Keiichi; Miike, Teruhisa

    1991-01-01

    Single photon emission computed tomography (SPECT) with N-isoprophyl-p [ 123 I]-iodoamphetamine (IMP), X-ray computed tomography (X-CT), and magnetic resonance imaging (MRI) were performed in 20 children with idiopathic seizures. In children with idiopathic seizures, SPECT could detect the abnormal sites at the highest rate (45%) compared with CT (10%) and MRI (12%), but the abnormal sites on SPECT correlated poorly with the foci on electroencephalograph (EEG). Idiopathic epilepsy with hypoperfusion on SPECT was refractory to treatment and was frequently associated with mental and/or developmental retardation. Perfusion defects on SPECT scans probably affect the development and maturation of the brain in children. (author)

  6. Single Photon Emission Computed Tomography (SPECT)

    Science.gov (United States)

    ... examined for the location of the tracer. Computer graphics can be used to create a 3-dimensional ... a Second Heart Attack | Spanish Cardiac Rehab Referral Card | Spanish Heart Attack Warning Signs: Patient sheet | Infographic | ...

  7. Recurrent ovarian endodermal sinus tumor: demonstration by computed tomography, magnetic resonance imaging, and positron emission tomography

    International Nuclear Information System (INIS)

    Romero, J.A.; Kim, E.E.; Tresukosol, D.; Kudelka, A.P.; Edwards, C.L.; Kavanagh, J.J.

    1995-01-01

    We report a case of recurrent endodermal sinus tumor of the ovary that was identified and/or clearly depicted by computed tomography, magnetic resonance imaging, and positron emission tomography. The potential roles of various imaging modalities in the detection of recurrent endodermal sinus tumor are discussed. (orig.)

  8. Fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography in evaluation of residual intramuscular myxoma

    International Nuclear Information System (INIS)

    Zade, Anand; Ahire, Archana; Shetty, Shishir; Rai, Sujith; Bokka, Rajashekharrao; Velumani, Arokiaswamy; Kabnurkar, Rasika

    2015-01-01

    Intramuscular myxoma (IM) is a rare benign neoplasm. In a patient diagnosed with IM of left thigh, we report the utility of a postoperative fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography scan in assessing the efficacy of surgical excision

  9. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  10. Fluorodeoxyglucose Positron Emission Tomography–Computed Tomography in Disseminated Cryptococcosis

    Science.gov (United States)

    Tripathy, Sarthak; Parida, Girish Kumar; Roy, Shambo Guha; Singhal, Abhinav; Mallick, Saumya Ranjan; Tripathi, Madhavi; Shamim, Shamim Ahmed

    2017-01-01

    Disseminated cryptococcosis without pulmonary involvement is a very rare phenomenon. Patterns of organ involvement in cryptococcosis resemble various other infective conditions as well as malignant conditions on fluorodeoxyglucose positron emission tomography–computed tomography. We present a case of a 43-year-old male patient who had disseminated cryptococcosis. The rarity of the case being noninvolvement of lungs and meninges and resembling more like lymphoma due to the diffuse involvement of the lymph nodes on both sides of the diaphragm. PMID:29142368

  11. Measurement of liver volume by emission computed tomography

    International Nuclear Information System (INIS)

    Kan, M.K.; Hopkins, G.B.

    1979-01-01

    In 22 volunteers without clinical or laboratory evidence of liver disease, liver volume was determined using single-photon emission computed tomography (ECT). This technique provided excellent object contrast between the liver and its surroundings and permitted calculation of liver volume without geometric assumptions about the liver's configuration. Reproducibility of results was satisfactory, with a root-mean-square error of less than 6% between duplicate measurements in 15 individuals. The volume measurements were validated by the use of phantoms

  12. 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography in Tuberculosis: Spectrum of Manifestations.

    Science.gov (United States)

    Agarwal, Krishan Kant; Behera, Abhishek; Kumar, Rakesh; Bal, Chandrasekhar

    2017-01-01

    The objective of this article is to provide an illustrative tutorial highlighting the utility of 18 F-fluorodeoxyglucose-positron emission tomography/computed tomography ( 18 F-FDG-PET/CT) imaging to detect spectrum of manifestations in patients with tuberculosis (TB). FDG-PET/CT is a powerful tool for early diagnosis, measuring the extent of disease (staging), and consequently for evaluation of response to therapy in patients with TB.

  13. Single photon emission computed tomography in AIDS dementia complex

    International Nuclear Information System (INIS)

    Pohl, P.; Vogl, G.; Fill, H.; Roessler, H.Z.; Zangerle, R.; Gerstenbrand, F.

    1988-01-01

    Single photon emission computed tomography (SPECT) studies were performed in AIDS dementia complex using IMP in 12 patients (and HM-PAO in four of these same patients). In all patients, SPECT revealed either multiple or focal uptake defects, the latter corresponding with focal signs or symptoms in all but one case. Computerized tomography showed a diffuse cerebral atrophy in eight of 12 patients, magnetic resonance imaging exhibited changes like atrophy and/or leukoencephalopathy in two of five cases. Our data indicate that both disturbance of cerebral amine metabolism and alteration of local perfusion share in the pathogenesis of AIDS dementia complex. SPECT is an important aid in the diagnosis of AIDS dementia complex and contributes to the understanding of the pathophysiological mechanisms of this disorder

  14. Imaging local brain function with emission computed tomography

    International Nuclear Information System (INIS)

    Kuhl, D.E.

    1984-01-01

    Positron emission tomography (PET) using 18 F-fluorodeoxyglucose (FDG) was used to map local cerebral glucose utilization in the study of local cerebral function. This information differs fundamentally from structural assessment by means of computed tomography (CT). In normal human volunteers, the FDG scan was used to determine the cerebral metabolic response to conrolled sensory stimulation and the effects of aging. Cerebral metabolic patterns are distinctive among depressed and demented elderly patients. The FDG scan appears normal in the depressed patient, studded with multiple metabolic defects in patients with multiple infarct dementia, and in the patients with Alzheimer disease, metabolism is particularly reduced in the parietal cortex, but only slightly reduced in the caudate and thalamus. The interictal FDG scan effectively detects hypometabolic brain zones that are sites of onset for seizures in patients with partial epilepsy, even though these zones usually appear normal on CT scans. The future prospects of PET are discussed

  15. Shielding Calculations for Positron Emission Tomography - Computed Tomography Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Baasandorj, Khashbayar [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Yang, Jeongseon [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-10-15

    Integrated PET-CT has been shown to be more accurate for lesion localization and characterization than PET or CT alone, and the results obtained from PET and CT separately and interpreted side by side or following software based fusion of the PET and CT datasets. At the same time, PET-CT scans can result in high patient and staff doses; therefore, careful site planning and shielding of this imaging modality have become challenging issues in the field. In Mongolia, the introduction of PET-CT facilities is currently being considered in many hospitals. Thus, additional regulatory legislation for nuclear and radiation applications is necessary, for example, in regulating licensee processes and ensuring radiation safety during the operations. This paper aims to determine appropriate PET-CT shielding designs using numerical formulas and computer code. Since presently there are no PET-CT facilities in Mongolia, contact was made with radiological staff at the Nuclear Medicine Center of the National Cancer Center of Mongolia (NCCM) to get information about facilities where the introduction of PET-CT is being considered. Well-designed facilities do not require additional shielding, which should help cut down overall costs related to PET-CT installation. According to the results of this study, building barrier thicknesses of the NCCM building is not sufficient to keep radiation dose within the limits.

  16. Spectrum of single photon emission computed tomography/computed tomography findings in patients with parathyroid adenomas.

    Science.gov (United States)

    Chakraborty, Dhritiman; Mittal, Bhagwant Rai; Harisankar, Chidambaram Natrajan Balasubramanian; Bhattacharya, Anish; Bhadada, Sanjay

    2011-01-01

    Primary hyperparathyroidism results from excessive parathyroid hormone secretion. Approximately 85% of all cases of primary hyperparathyroidism are caused by a single parathyroid adenoma; 10-15% of the cases are caused by parathyroid hyperplasia. Parathyroid carcinoma accounts for approximately 3-4% of cases of primary disease. Technetium-99m-sestamibi (MIBI), the current scintigraphic procedure of choice for preoperative parathyroid localization, can be performed in various ways. The "single-isotope, double-phase technique" is based on the fact that MIBI washes out more rapidly from the thyroid than from abnormal parathyroid tissue. However, not all parathyroid lesions retain MIBI and not all thyroid tissue washes out quickly, and subtraction imaging is helpful. Single photon emission computed tomography (SPECT) provides information for localizing parathyroid lesions, differentiating thyroid from parathyroid lesions, and detecting and localizing ectopic parathyroid lesions. Addition of CT with SPECT improves the sensitivity. This pictorial assay demonstrates various SPECT/CT patterns observed in parathyroid scintigraphy.

  17. Promising role of single photon emission computed tomography/computed tomography in Meckel's scan

    International Nuclear Information System (INIS)

    Jain, Anurag; Chauhan, MS; Pandit, AG; Kumar, Rajeev; Sharma, Amit

    2012-01-01

    Meckel's scan is a common procedure performed in nuclear medicine. Single-photon emission computed tomography/computed tomography (SPECT/CT) in a suspected case of heterotopic location of gastric mucosa can increase the accuracy of its anatomic localization. We present two suspected cases of Meckel's diverticulum in, which SPECT/CT co-registration has helped in better localization of the pathology

  18. Acute Calculous Cholecystitis Missed on Computed Tomography and Ultrasound but Diagnosed with Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Carina Mari Aparici

    2016-01-01

    Full Text Available We present a case of a 69-year-old patient who underwent ascending aortic aneurysm repair with aortic valve replacement. On postsurgical day 12, he developed leukocytosis and low-grade fevers. The chest computed tomography (CT showed a periaortic hematoma which represents a postsurgical change from aortic aneurysm repair, and a small pericardial effusion. The abdominal ultrasound showed cholelithiasis without any sign of cholecystitis. Finally, a fluorodeoxyglucose (FDG-positron emission tomography (PET/CT examination was ordered to find the cause of fever of unknown origin, and it showed increased FDG uptake in the gallbladder wall, with no uptake in the lumen. FDG-PET/CT can diagnose acute cholecystitis in patients with nonspecific clinical symptoms and laboratory results.

  19. Quantified measurement of brain blood volume: comparative evaluations between the single photon emission computer tomography and the positron computer tomography

    International Nuclear Information System (INIS)

    Bouvard, G.; Fernandez, Y.; Petit-Taboue, M.C.; Derlon, J.M.; Travere, J.M.; Le Poec, C.

    1991-01-01

    The quantified measurement of cerebral blood volume is interesting for the brain blood circulation studies. This measurement is often used in positron computed tomography. It's more difficult in single photon emission computed tomography: there are physical problems with the limited resolution of the detector, the Compton effect and the photon attenuation. The objectif of this study is to compare the results between these two techniques. The quantified measurement of brain blood volume is possible with the single photon emission computer tomogragry. However, there is a loss of contrast [fr

  20. Single-photon emission computed tomography/computed tomography in lung cancer and malignant lymphoma.

    Science.gov (United States)

    Schillaci, Orazio

    2006-10-01

    In nuclear oncology, despite the fast-growing diffusion of (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET), single-photon emission computed tomography (SPECT) studies can still play an useful clinical role in several applications. The main limitation of SPECT imaging with tumor-seeking agents is the lack of the structural delineation of the pathologic processes they detect; this drawback sometimes renders SPECT interpretation difficult and can diminish its diagnostic accuracy. Fusion with morphological studies can overcome this limitation by giving an anatomical map to scintigraphic data. In the past, software-based fusion of independently performed SPECT and CT images proved to be time-consuming and impractical for routine use. The recent development of dual-modality integrated imaging systems that provide functional (SPECT) and anatomical (CT) images in the same scanning session, with the acquired images coregistered by means of the hardware, has opened a new era in this field. The first reports indicate that SPECT/CT is very useful in cancer imaging because it is able to provide further information of clinical value in several cases. In SPECT, studies of lung cancer and malignant lymphomas using different radiopharmaceutical, hybrid images are of value in providing the correct localization of tumor sites, with a precise detection of the involved organs, and the definition of their functional status, and in allowing the exclusion of disease in sites of physiologic tracer uptake. Therefore, in lung cancer and lymphomas, hybrid SPECT/CT can play a role in the diagnosis of the primary tumor, in the staging of the disease, in the follow-up, in the monitoring of therapy, in the detection of recurrence, and in dosimetric estimations for target radionuclide therapy.

  1. The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in resectable pancreatic cancer.

    Science.gov (United States)

    Crippa, Stefano; Salgarello, Matteo; Laiti, Silvia; Partelli, Stefano; Castelli, Paola; Spinelli, Antonello E; Tamburrino, Domenico; Zamboni, Giuseppe; Falconi, Massimo

    2014-08-01

    The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in pancreatic ductal adenocarcinoma is debated. We retrospectively assessed the value of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in addition to conventional imaging as a staging modality in pancreatic cancer. (18)Fluoro-deoxyglucose positron emission tomography/computed tomography was performed in 72 patients with resectable pancreatic carcinoma after multi-detector computed tomography positron emission tomography was considered positive for a maximum standardized uptake value >3. Overall, 21% of patients had a maximum standardized uptake value ≤ 3, and 60% of those had undergone neoadjuvant treatment (P=0.0001). Furthermore, 11% of patients were spared unwarranted surgery since positron emission tomography/computed tomography detected metastatic disease. All liver metastases were subsequently identified with contrast-enhanced ultrasound. Sensitivity and specificity of positron emission tomography/computed tomography for distant metastases were 78% and 100%. The median CA19.9 concentration was 48.8 U/mL for the entire cohort and 292 U/mL for metastatic patients (P=0.112). The widespread application of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in patients with resectable pancreatic carcinoma seems not justified. It should be considered in selected patients at higher risk of metastatic disease (i.e. CA19.9>200 U/mL) after undergoing other imaging tests. Neoadjuvant treatment is significantly associated with low metabolic activity, limiting the value of positron emission tomography in this setting. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  2. Diagnostic utility of fluorodeoxyglucose positron emission tomography/computed tomography in pyrexia of unknown origin

    International Nuclear Information System (INIS)

    Singh, Nidhi; Kumar, Rakesh; Malhotra, Arun; Bhalla, Ashu Seith; Kumar, Uma; Sood, Rita

    2005-01-01

    The present study was undertaken to evaluate the diagnostic utility of fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) in patients presenting as pyrexia of unknown origin (PUO). Forty-seven patients (31 males and 16 females; mean age of 42.7 ± 19.96 years) presenting as PUO to the Department of Medicine at the All India Institute of Medical Sciences, New Delhi over a period of 2 years underwent F-18 FDG PET/CT. PET ⁄ CT was considered supportive when its results correlated with the final definitive diagnosis. Final diagnosis was made on the basis of combined evaluation of history, clinical findings, investigations, and response to treatment. Thirty-five PET/CT studies (74.5%) were positive. However, only 18 (38.3%) were supportive of the final diagnosis. In three patients (6.4%), PET/CT was considered diagnostic as none of the other investigations including contrast-enhanced computed tomography of chest and abdomen, and directed tissue sampling could lead to the final diagnosis. All these three patients were diagnosed as aortoarteritis. Fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography is an important emerging modality in the workup of PUO. It supported the final diagnosis in 38% of our patients and was diagnostic in 6.4% of patients. Thus, PET/CT should only be considered as second-line investigation for the diagnostic evaluation of PUO; especially in suspected noninfectious inflammatory disorders

  3. Single photon emission computed tomography of the liver

    International Nuclear Information System (INIS)

    Makler, P.T. Jr.

    1988-01-01

    Single photon emission computed tomography (SPECT) of the liver has been introduced in order to improve sensitivity and localization of space-occupying lesions. There have been numerous reports on the usefulness of the technique, as well as extensive analyses of its technical drawbacks. In general, SPECT provides a more accurate estimation of defect size than does conventional planar scintigraphy for cases in which one wishes to evaluate changes in lesion size due to therapy. The presence of a superimposed parenchymal disease, however, remains a major problem, which will only be resolved by a scanning technique that specifically detects the disease process of concern (hot spot imaging) rather than displacement of normal tissue (cold spot imaging)

  4. Fluorodeoxyglucose positron emission tomography-computed tomography findings in a case of xanthogranulomatous pyelonephritis

    Science.gov (United States)

    Joshi, Prathamesh; Lele, Vikram; Shah, Hardik

    2013-01-01

    Xanthogranulomatous pyelonephritis (XGNP) is an uncommon condition characterized by chronic suppurative renal inflammation that leads to progressive parenchymal destruction. This condition can clinically present as recurrent urinary tract infections, flank pain, hematuria, and occasionally sepsis, and weight loss. This condition is usually associated with obstructing renal calculus. We present 18-fluorodeoxyglucose positron emission tomography-computed tomography (18-FDG PET/CT) findings in an elderly male suffering from pyrexia and weight loss and suspected urinary tract infection. PET/CT findings in this case lead to diagnosis of XGNP. This diagnosis should be kept in mind while evaluating similar symptoms and PET/CT scan findings. PMID:24019680

  5. Position emission tomography with or without computed tomography in the primary staging of Hodgkin's lymphoma

    DEFF Research Database (Denmark)

    Hutchings, Martin; Loft, Annika; Hansen, Mads

    2006-01-01

    BACKGROUND AND OBJECTIVES: In order to receive the most appropriate therapy, patients with Hodgkin's lymphoma (HL) must be accurately stratified into different prognostic staging groups. Computed tomography (CT) plays a pivotal role in the conventional staging. The aim of the present study...... was to investigate the value of positron emission tomography using 2-[18F]fluoro-2-deoxy-D-glucose (FDG-PET) and combined FDG-PET/CT for the staging of HL patients, and the impact on the choice of treatment. DESIGN AND METHODS: Ninety-nine consecutive, prospectively included patients had FDG-PET and CT...

  6. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography

    DEFF Research Database (Denmark)

    Rochitte, Carlos E; George, Richard T; Chen, Marcus Y

    2014-01-01

    AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed...... emission computed tomography (SPECT/MPI). Sixteen centres enroled 381 patients who underwent combined CTA-CTP and SPECT/MPI prior to conventional coronary angiography. All four image modalities were analysed in blinded independent core laboratories. The prevalence of obstructive CAD defined by combined ICA...... tomography (SPECT). METHODS AND RESULTS: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon...

  7. Iterative concurrent reconstruction algorithms for emission computed tomography

    International Nuclear Information System (INIS)

    Brown, J.K.; Hasegawa, B.H.; Lang, T.F.

    1994-01-01

    Direct reconstruction techniques, such as those based on filtered backprojection, are typically used for emission computed tomography (ECT), even though it has been argued that iterative reconstruction methods may produce better clinical images. The major disadvantage of iterative reconstruction algorithms, and a significant reason for their lack of clinical acceptance, is their computational burden. We outline a new class of ''concurrent'' iterative reconstruction techniques for ECT in which the reconstruction process is reorganized such that a significant fraction of the computational processing occurs concurrently with the acquisition of ECT projection data. These new algorithms use the 10-30 min required for acquisition of a typical SPECT scan to iteratively process the available projection data, significantly reducing the requirements for post-acquisition processing. These algorithms are tested on SPECT projection data from a Hoffman brain phantom acquired with a 2 x 10 5 counts in 64 views each having 64 projections. The SPECT images are reconstructed as 64 x 64 tomograms, starting with six angular views. Other angular views are added to the reconstruction process sequentially, in a manner that reflects their availability for a typical acquisition protocol. The results suggest that if T s of concurrent processing are used, the reconstruction processing time required after completion of the data acquisition can be reduced by at least 1/3 T s. (Author)

  8. Fluorodeoxyglucose-positron emission tomography/computed tomography imaging features of colloid adenocarcinoma of the lung: a case report.

    Science.gov (United States)

    Wang, ZhenGuang; Yu, MingMing; Chen, YueHua; Kong, Yan

    2017-07-27

    Colloid adenocarcinoma of the lung is a rare subtype of variants of invasive adenocarcinomas. We report the appearance of this unusual entity on 18 F-fluorodeoxyglucose positron emission tomography/computed tomography. A 60-year-old man of Chinese Han nationality coughed with a little white sputum for 1 month. Chest computed tomography showed multiple bilateral subpleural nodules and plaques accompanied by air bronchograms, which were most concentrated in the lower lobe of his right lung. Positron emission tomography indicated increased radioactivity uptake with a maximum standardized uptake value of 3.5. Positron emission tomography/computed tomography showed a soft tissue density lesion in his left adrenal gland with a maximum standardized uptake value of 4.1. The positron emission tomography/computed tomography appearance suggested a primary colloid adenocarcinoma in the lower lobe of his right lung accompanied by intrapulmonary and left adrenal gland metastases. The diagnostic rate of colloid adenocarcinoma can be increased by combining the anatomic and metabolic information of lesions. The advantage of positron emission tomography/computed tomography in the diagnosis of colloid adenocarcinoma, as with other cancers, is the ability to locate extrapulmonary disease, facilitating clinical staging.

  9. Positron emission tomography of malignant tumours at head and neck. Evaluation of the diagnostic value of positron emission tomography by comparison with computed tomography

    International Nuclear Information System (INIS)

    Kettler, Nele

    2011-01-01

    Imaging methods for early, accurate diagnosis and aftercare of malignant growths is currently one of the most important research topics. The objective of this thesis is to evaluate the diagnostic value of FDG-positron emission tomography by comparison with computed tomography for patients with squamous cell carcinoma, malignant melanoma or sarcoma at head and neck. Measurement criteria are sensitivity and specificity. A retrospective evaluation of 100 examinations on 85 patients of University clinic Aachen was performed. The examination reports were supported by reports from histology, positron emission tomography and computed tomography. In each case, the histological results were assumed to provide a reliable benchmark. Sensitivity and specificity for the primary tumour site, metastatic lymphatic nodes and defined anatomic structures were compared across all patients. Comparisons were also performed on sub groups separated by gender, cancer type and the time and frequency at which tumours arose. The statistic analysis was done with MedCalc. Results: The results for sensitivity and specificity of the primary tumour site were 86.42% and 42.86%, and 64.71% and 66.07%, for positron emission tomography and computed tomography respectively. The results for the lymphatic nodes were 51.52% and 92.86% and 64.71% and 66.07%. When the constituent anatomic structures were evaluated separately, the specificity was significantly higher. The separation by gender showed no difference. Because the classification by tumor type resulted in samples that were of varying size, a comparison was difficult. For the diagnosis of primary tumours, the examination with positron emission tomography was superior, whereas computed tomography proved more effective for the diagnosis of recurrent tumours. For the diagnosis of the main tumour site, both methods were shown to be equally suitable. For the assessment of lymphatic nodes, positron emission tomography was superior to computed tomography

  10. Efficacy of 3D-positron emission tomography/computed tomography for upper abdomen.

    Science.gov (United States)

    Murakami, Koji; Nakahara, Tadaki

    2014-04-01

    Recent advancement in computed tomography (CT) enables us to obtain high spatial resolution image and made it possible to construct extensive high-definition three-dimensional (3D) images. But a lack of contrast resolution in CT alone is still remained problem. Meanwhile, as fluorodeoxyglucose-positron emission tomography (PET) can visualize tumors in high contrast, we can create 3D images fusing the accumulation in tumors on PET/CT images. Such images can play the role of a "map of body" which makes it easy to understand the anatomical information before surgery. We also try to evaluate segmental liver function by using PET/CT fusion images. By using (11) C-methionine PET/contrast-enhanced CT, superior image quality compared to single photon emission computed tomography/CT can be obtained. CT, especially with contrast enhancement for obtaining anatomical imaging information plus PET for obtaining functional imaging information is a highly compatible combination, and adding these two types information will further increase clinical usefulness. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  11. Brain single photon emission computed tomography in neonates

    International Nuclear Information System (INIS)

    Denays, R.; Van Pachterbeke, T.; Tondeur, M.

    1989-01-01

    This study was designed to rate the clinical value of [ 123 I]iodoamphetamine (IMP) or [ 99m Tc] hexamethyl propylene amine oxyme (HM-PAO) brain single photon emission computed tomography (SPECT) in neonates, especially in those likely to develop cerebral palsy. The results showed that SPECT abnormalities were congruent in most cases with structural lesions demonstrated by ultrasonography. However, mild bilateral ventricular dilatation and bilateral subependymal porencephalic cysts diagnosed by ultrasound were not associated with an abnormal SPECT finding. In contrast, some cortical periventricular and sylvian lesions and all the parasagittal lesions well visualized in SPECT studies were not diagnosed by ultrasound scans. In neonates with subependymal and/or intraventricular hemorrhage the existence of a parenchymal abnormality was only diagnosed by SPECT. These results indicate that [ 123 I]IMP or [ 99m Tc]HM-PAO brain SPECT shows a potential clinical value as the neurodevelopmental outcome is clearly related to the site, the extent, and the number of cerebral lesions. Long-term clinical follow-up is, however, mandatory in order to define which SPECT abnormality is associated with neurologic deficit

  12. 67Ga-emission computed tomography in bronchogenic carcinoma

    International Nuclear Information System (INIS)

    Ichiya, Yuichi; Oshiumi, Yoshihiko; Kuwabara, Yasuo; Wada, Makoto; Ayabe, Zenji; Matsuura, Keiichi

    1982-01-01

    Both conventional 67 Ga scintigraphy and 67 Ga emission computed tomography (ECT) were performed in 36 patients with bronchogenic carcinoma to evaluate clinical significance of 67 Ga-ECT as an adjunctive method. Each patient received 111 -- 185 MBq (3 -- 5 mCi) of 67 Ga-citrate intravenously. A rotation #betta# camera (Shimadzu LFOV-E) was used for ECT study, and a #betta# camera (Searle LFOV) was used for conventional scintigraphy. The detectability of 67 Ga scintigraphy with ECT in primary tumors and regional lymph node metastases was compared retrospectively with that of conventional 67 Ga scintigraphy alone. There was little improvement in detection of primary and metastatic lesions by adding 67 Ga-ECT. Only 3 primary tumors were demonstrated more distinctly by 67 Ga-ECT. However, there was no lesion which was detected only by 67 Ga-ECT. Our data indicate that inclusion of 67 Ga-ECT in the routine examination is unnecessary in cases with bronchogenic carcinoma. (author)

  13. Gallium tomoscintigraphic imaging of esophageal cancer using emission computed tomography

    International Nuclear Information System (INIS)

    Hattori, Takao; Nakagawa, Tsuyoshi; Takeda, Kan; Maeda, Hisato; Taguchi, Mitsuo

    1983-01-01

    Emission computed tomography (ECT) was clinically evaluated in 67 Ga imaging of esophageal cancer. ECT system used in this study is equipped with opposed dual large-field-of-view cameras (GCA 70A-S, Toshiba Co.). Data were acquired by rotating the two cameras 180 0 about the longitudinal axis of the patient. Total acquisition time was about 12 minutes. Multiple slices of transaxial, sagittal and coronal sections were reconstructed in a 64 x 64 matrix form using convolution algorithms. In three out of six cases studied the tumor uptake was not detected on conventional images, because the lesion was small, concentration of activity was poor or the lesion activity was overlapped with the neighbouring activities distributed to normal organs such as sternum, vertebra, liver and hilus. On ECT images, by contrast, abnormal uptake of the tumors was definitively detected in all the six cases. ECT imaging was also useful in estimating the effect of treatment by the decrease in 67 Ga concentration. We have devised a special technique to repeat ECT scan with a thin tube filled with 67 Ga solution inserted through the esophagus. By this technique, comparing paired images with and without the tube activity, exact location of the uptake against the esophagus and extraesophageal extension of the disease could be accurately evaluated in a three-dimensional field of view. ECT in gallium scanning is expected to be of great clinical value to elevate the confidence level of diagnosis in detecting, localizing and following up the diseases. (author)

  14. Proceedings of clinical SPECT [single photon emission computed tomography] symposium

    International Nuclear Information System (INIS)

    1986-09-01

    It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have selected the key areas which demand awareness and attention in order to make SPECT operational in clinical practice. These include selection of equipment, details of uniformity correction, utilization of phantoms for equipment acceptance and quality assurance, the major aspect of algorithms, an understanding of filtered back projection and appropriate choice of filters and an awareness of the most commonly generated artifacts and how to recognize them. With respect to the acquisition and interpretation of organ images, the faculty will present information on the major aspects of hepatic, brain, cardiac, skeletal, and immunologic imaging techniques. Individual papers are processed separately for the data base

  15. Single-Photon Emission Computed Tomography (SPECT) in childhood epilepsy

    International Nuclear Information System (INIS)

    Gulati, Sheffali; Kalra, Veena; Bal, C.S.

    2000-01-01

    The success of epilepsy surgery is determined strongly by the precise location of the epileptogenic focus. The information from clinical electrophysiological data needs to be strengthened by functional neuroimaging techniques. Single photon emission computed tomography (SPECT) available locally has proved useful as a localising investigation. It evaluates the regional cerebral blood flow and the comparison between ictal and interictal blood flow on SPECT has proved to be a sensitive nuclear marker for the site of seizure onset. Many studies justify the utility of SPECT in localising lesions to possess greater precision than interictal scalp EEG or anatomic neuroimaging. SPECT is of definitive value in temporal lobe epilepsy. Its role in extratemporal lobe epilepsy is less clearly defined. It is useful in various other generalized and partial seizure disorders including epileptic syndromes and helps in differentiating pseudoseizures from true seizures. The need for newer radiopharmaceutical agents with specific neurochemical properties and longer shelf life are under investigation. Subtraction ictal SPECT co-registered to MRI is a promising new modality. (author)

  16. F-18-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Appearance of Extramedullary Hematopoesis in a Case of Primary Myelofibrosis

    Science.gov (United States)

    Mukherjee, Anirban; Bal, Chandrasekhar; Tripathi, Madhavi; Das, Chandan Jyoti; Shamim, Shamim Ahmed

    2017-01-01

    A 44-year-old female with known primary myelofibrosis presented with shortness of breath. High Resolution Computed Tomography thorax revealed large heterogeneously enhancing extraparenchymal soft tissue density mass involving bilateral lung fields. F-18-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography revealed mildly FDG avid soft tissue density mass with specks of calcification involving bilateral lung fields, liver, and spleen. Subsequent histopathologic evaluation from the right lung mass was suggestive of extramedullary hematopoesis. PMID:28533647

  17. The Comparison of Computed Tomography Perfusion, Contrast-Enhanced Computed Tomography and Positron-Emission Tomography/Computed Tomography for the Detection of Primary Esophageal Carcinoma.

    Science.gov (United States)

    Genc, Berhan; Kantarci, Mecit; Sade, Recep; Orsal, Ebru; Ogul, Hayri; Okur, Aylin; Aydin, Yener; Karaca, Leyla; Eroğlu, Atilla

    2016-01-01

    The purpose of this study was to investigate the efficiency of computed tomography perfusion (CTP), contrast-enhanced computed tomography (CECT) and 18F-fluoro-2-deoxy-D-glucose (18F-FDG) positron-emission tomography (PET/CT) in the diagnosis of esophageal cancer. This prospective study consisted of 33 patients with pathologically confirmed esophageal cancer, 2 of whom had an esophageal abscess. All the patients underwent CTP, CECT and PET/CT imaging and the imaging findings were evaluated. Sensitivity, specificity and positive and negative predictive values were calculated for each of the 3 imaging modalities relative to the histological diagnosis. Thirty-three tumors were visualized on CTP, 29 on CECT and 27 on PET/CT. Six tumors were stage 1, and 2 and 4 of these tumors were missed on CECT and PET/CT, respectively. Significant differences between CTP and CECT (p = 0.02), and between CTP and PET/CT (p = 0.04) were found for stage 1 tumors. Values for the sensitivity, specificity and positive and negative predictive values on CTP were 100, 100, 100 and 100%, respectively. Corresponding values on CECT were 93.94, 0, 93.94 and 0%, respectively, and those on PET/CT were 87.88, 0, 93.55 and 0%, respectively. Hence, the sensitivity, specificity and positive and negative predictive values of CTP were better than those of CECT and PET/CT. CTP had an advantage over CECT and PET/CT in detecting small lesions. CTP was valuable, especially in detecting stage 1 tumors. © 2016 S. Karger AG, Basel.

  18. Fasciola Hepatica Mimicking Malignancy on 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Science.gov (United States)

    Sürücü, Erdem; Demir, Yusuf; Dülger, Ahmet C.; Batur, Abdüssamed; Ölmez, Şehmus; Kitapçı, Mehmet T.

    2016-01-01

    A 48-year-old female with complaints of gastrointestinal symptoms such as abdominal pain, fatigue, vomiting, nausea, and weight loss was diagnosed with neuroendocrine tumor after removal of a 2 mm lesion from the stomach with endoscopic biopsy. Her magnetic resonance imaging that was performed due to on-going symptoms showed multiple linear hypointense lesions in the liver. Positron emission tomography/computed tomography (PET/CT) scan was performed for differential diagnosis, which showed high fluorodeoxyglucose (FDG) uptake in these lesions. Clinical and laboratory findings revealed the final diagnosis as Fasciola hepatica. The imaging features of this case is presented to aid in differentiating this infectious disease from malignancy and avoid misdiagnosis on FDG-PET/CT. PMID:27751978

  19. Prognostic Evaluation of 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in Endometrial Cancer

    DEFF Research Database (Denmark)

    Vilstrup, Mie Holm; Jochumsen, Kirsten M; Hess, Søren

    2017-01-01

    .19-8.49) and 1.93 (0.80-4.68), respectively. Whole-body cTLG of greater than or equal to 176.1 g yielded a hazard ratio of 5.70 (1.94-16.78) for OS in a multivariate analysis. CONCLUSIONS: Preoperative SUVmax and cTLG showed potential as independent prognostic markers of OS in patients with primarily high...... and a preoperative F-fluorodeoxyglucose positron emission tomography/computed tomography before curatively intended treatment were included. The scans were evaluated using standard uptake values [maximum standard uptake value (SUVmax) and partial volume corrected (c) mean standardized uptake value (SUVmean...... proportional regression models were used for prognostic evaluation. RESULTS: Eighty-three patients (median age, 69.9 y; range, 26.8-91.1) with primarily high-risk endometrial cancer or suspected high The International Federation of Gynecology and Obstetrics stage were included. Mean follow-up time was 3...

  20. Fasciola Hepatica Mimicking Malignancy on 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Erdem Sürücü

    2016-10-01

    Full Text Available A 48-year-old female with complaints of gastrointestinal symptoms such as abdominal pain, fatigue, vomiting, nausea, and weight loss was diagnosed with neuroendocrine tumor after removal of a 2 mm lesion from the stomach with endoscopic biopsy. Her magnetic resonance imaging that was performed due to on-going symptoms showed multiple linear hypointense lesions in the liver. Positron emission tomography/computed tomography (PET/CT scan was performed for differential diagnosis, which showed high fluorodeoxyglucose (FDG uptake in these lesions. Clinical and laboratory findings revealed the final diagnosis as Fasciola hepatica. The imaging features of this case is presented to aid in differentiating this infectious disease from malignancy and avoid misdiagnosis on FDG-PET/CT.

  1. Positron emission tomography/computed tomography and radioimmunotherapy of prostate cancer

    DEFF Research Database (Denmark)

    Bouchelouche, Kirsten; Capala, Jacek; Oehr, Peter

    2009-01-01

    of a number of diagnostic and therapeutic strategies. J591, a monoclonal antibody, which targets the extracellular domain of prostate-specific membrane antigen, shows promising results. HER2 receptors may also have a potential as target for PET/CT imaging and RIT of advanced prostate cancer. SUMMARY: PET......PURPOSE OF REVIEW: Traditional morphologically based imaging modalities are now being complemented by positron emission tomography (PET)/computed tomography (CT) in prostate cancer. Metastatic prostate cancer is an attractive target for radioimmunotherapy (RIT) as no effective therapies...... are available. This review highlights the most important achievements within the last year in PET/CT and RIT of prostate cancer. RECENT FINDINGS: Conflicting results exist on the use of choline for detection of malignant disease in the prostate gland. The role of PET/CT in N-staging remains to be elucidated...

  2. Fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of primary pulmonary angiosarcomas

    International Nuclear Information System (INIS)

    Krishnamurthy, Arvind; Nayak, Deepika; Ramshankar, Vijayalakshmi; Majhi, Urmila

    2015-01-01

    Angiosarcoma is a malignant vascular tumor that originates from the mesenchymal cells which have undergone angioblastic differentiation. Pulmonary angiosarcomas are invariably (>90%) metastatic tumors form primaries of the skin, bone, liver, breast, or heart. Primary pulmonary angiosarcomas are exceedingly rare, with just about 20 cases being reported in the literature. We report an additional case with a brief review of the literature of a primary pulmonary angiosarcoma in a 26-year-old lady who presented with intractable hemoptysis. In addition, we highlight the potential of fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography as an important diagnostic tool in the evaluation of this tumor and thus contribute to the existing sparse literature on this fascinating yet devastating disease

  3. Role of Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in Diagnostic Evaluation of Carcinoma Urinary Bladder: Comparison with Computed Tomography

    International Nuclear Information System (INIS)

    Chakraborty, Dhritiman; Mittal, Bhagwant Rai; Kashyap, Raghava; Mete, Utham Kumar; Narang, Vikram; Das, Ashim; Bhattacharya, Anish; Khandelwal, Niranjan; Mandal, Arup K.

    2014-01-01

    Bladder carcinoma is the most frequent tumor of the urinary tract and accounts 7% of all malignancies in men and 2% of all malignancies in women. This retrospective study was carried out to assess the diagnostic utility of F18-fludeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in the imaging evaluation of bladder carcinoma. Seventy-seven consecutive patients diagnosed to have carcinoma urinary bladder referred for F18-FDG PET/CT were included in this study. Thirty-four patients were for initial staging after transurethral biopsy and remaining 43 patients were for restaging. All patients also underwent CT scan of the abdomen and pelvis. PET/CT findings were correlated with diagnostic CT scan and histopathological findings. In 30 of the 34 patients for initial staging, both PET/CT and CT confirmed the primary lesion in the bladder. Histopathology report was available in 23 patients. Lymph nodes FDG uptake reported to be metastatic in 10/23 patients while CT detected lymph node metastasis in 12 patients. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy have been calculated to be 87.5%, 80%, 70%, 92%, 82% for PET/CT and 66%, 57%, 50%, 72%, 60% for CT respectively. PET/CT detected metastatic disease in 8 patients whereas CT detected in 4 patients. Of the 43 patients for restaging, local recurrence was detected in 24 patients on both PET/CT and CT. Histopathology report was available in 17 patients. Sensitivity, specificity, PPV, NPV and accuracy were 85%, 60%, 60%, 85%, 70% for PET/CT and 80%, 50%, 40%, 85%, 58% for CT respectively. Nineteen patients were detected to have metastatic disease by PET/CT, whereas CT detected metastases in 11 patients. F-18 FDG PET/CT is a very useful modality in pre-operative staging and monitoring after surgery, chemotherapy or radiotherapy of patients with carcinoma urinary bladder

  4. Cone beam tomography of the heart using single-photon emission-computed tomography

    International Nuclear Information System (INIS)

    Gullberg, G.T.; Christian, P.E.; Zeng, G.L.; Datz, F.L.; Morgan, H.T.

    1991-01-01

    The authors evaluated cone beam single-photon emission-computed tomography (SPECT) of the heart. A new cone beam reconstruction algorithm was used to reconstruct data collected from short scan acquisitions (of slightly more than 180 degrees) of a detector anteriorally traversing a noncircular orbit. The less than 360 degrees acquisition was used to minimize the attenuation artifacts that result from reconstructing posterior projections of 201T1 emissions from the heart. The algorithm includes a new method for reconstructing truncated projections of background tissue activity that eliminates reconstruction ring artifacts. Phantom and patient results are presented which compare a high-resolution cone beam collimator (50-cm focal length; 6.0-mm full width at half maximum [FWHM] at 10 cm) to a low-energy general purpose (LEGP) parallel hole collimator (8.2-mm FWHM at 10 cm) which is 1.33 times more sensitive. The cone beam tomographic results are free of reconstruction artifacts and show improved spatial and contrast resolution over that obtained with the LEGP parallel hole collimator. The limited angular sampling restrictions and truncation problems associated with cone beam tomography do not deter from obtaining diagnostic information. However, even though these preliminary results are encouraging, a thorough clinical study is still needed to investigate the specificity and sensitivity of cone beam tomography

  5. Is there any role of positron emission tomography computed tomography for predicting resectability of gallbladder cancer?

    Science.gov (United States)

    Kim, Jaihwan; Ryu, Ji Kon; Kim, Chulhan; Paeng, Jin Chul; Kim, Yong-Tae

    2014-05-01

    The role of integrated (18)F-2-fluoro-2-deoxy-D-glucose positron emission tomography computed tomography (PET-CT) is uncertain in gallbladder cancer. The aim of this study was to show the role of PET-CT in gallbladder cancer patients. Fifty-three patients with gallbladder cancer underwent preoperative computed tomography (CT) and PET-CT scans. Their medical records were retrospectively reviewed. Twenty-six patients underwent resection. Based on the final outcomes, PET-CT was in good agreement (0.61 to 0.80) with resectability whereas CT was in acceptable agreement (0.41 to 0.60) with resectability. When the diagnostic accuracy of the predictions for resectability was calculated with the ROC curve, the accuracy of PET-CT was higher than that of CT in patients who underwent surgical resection (P=0.03), however, there was no difference with all patients (P=0.12). CT and PET-CT had a discrepancy in assessing curative resection in nine patients. These consisted of two false negative and four false positive CT results (11.3%) and three false negative PET-CT results (5.1%). PET-CT was in good agreement with the final outcomes compared to CT. As a complementary role of PEC-CT to CT, PET-CT tended to show better prediction about resectability than CT, especially due to unexpected distant metastasis.

  6. An analysis of true- and false-positive results of vocal fold uptake in positron emission tomography-computed tomography imaging.

    Science.gov (United States)

    Seymour, N; Burkill, G; Harries, M

    2018-03-01

    Positron emission tomography-computed tomography with fluorine-18 fluorodeoxy-D-glucose has a major role in the investigation of head and neck cancers. Fluorine-18 fluorodeoxy-D-glucose is not a tumour-specific tracer and can also accumulate in benign pathology. Therefore, positron emission tomography-computed tomography scan interpretation difficulties are common in the head and neck, which can produce false-positive results. This study aimed to investigate patients detected as having abnormal vocal fold uptake on fluorine-18 fluorodeoxy-D-glucose positron emission tomography-computed tomography. Positron emission tomography-computed tomography scans were identified over a 15-month period where reports contained evidence of unilateral vocal fold uptake or vocal fold pathology. Patients' notes and laryngoscopy results were analysed. Forty-six patients were identified as having abnormal vocal fold uptake on positron emission tomography-computed tomography. Twenty-three patients underwent positron emission tomography-computed tomography and flexible laryngoscopy: 61 per cent of patients had true-positive positron emission tomography-computed tomography scans and 39 per cent had false-positive scan results. Most patients referred to ENT for abnormal findings on positron emission tomography-computed tomography scans had true-positive findings. Asymmetrical fluorine-18 fluorodeoxy-D-glucose uptake should raise suspicion of vocal fold pathology, accepting a false-positive rate of approximately 40 per cent.

  7. Proceedings of clinical SPECT (single photon emission computed tomography) symposium

    Energy Technology Data Exchange (ETDEWEB)

    1986-09-01

    It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have selected the key areas which demand awareness and attention in order to make SPECT operational in clinical practice. These include selection of equipment, details of uniformity correction, utilization of phantoms for equipment acceptance and quality assurance, the major aspect of algorithms, an understanding of filtered back projection and appropriate choice of filters and an awareness of the most commonly generated artifacts and how to recognize them. With respect to the acquisition and interpretation of organ images, the faculty will present information on the major aspects of hepatic, brain, cardiac, skeletal, and immunologic imaging techniques. Individual papers are processed separately for the data base. (TEM)

  8. Study of brain metabolism using positron emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Heiss, W D

    1983-03-21

    Positron emission tomography permits the three-dimensional regional measurement of metabolism and blood flow in the brain. For the determination of cerebral metabolic rates of glucose by PET /sup 18/fluordeoxyglucose is usually applied: cerebral metabolic rate of glucose was found to be 36 to 47 ..mu..mol/100 g/min in the grey matter and 23 to 29 ..mu..mol/100 g/min in the white matter of normal volunteers. During physiologic activation metabolic rate of glucose is increased in the respective brain areas in relation to the strength and complexity of the stimulation. In patients suffering from ischaemic stroke glucose metabolism is markedly decreased within the infarction. Additonally, glucose metabolism is reduced by 20% in morphologically intact areas of the homolateral cortex, in the basal ganglia, in the cortical area contralateral to the infarction and in the contralateral cerebellum. This remote reduction of glucose utilization is probably caused by functional inactivation of these brain structures; it could be responsible for the diffuse organic syndrome in stroke victims not caused by the focal lesion. In patients suffering from dementia of the multi-infarct type and of the Alzheimer type glucose metabolism is reduced; the lesions in Alzheimer cases are most prominent in partietal and frontal cortical areas. In Chorea Huntington cases glucose metabolism is primarily disturbed in the striate, especially in the caudate nucleus; in these cases the metabolic disturbance can be detected earlier than the atrophy in computed tomograms. Disturbances of glucose and oxygen utilization are not necessary causes, but may also be sequelae od functional impairment. Additional information on pathogentic mechanisms may be obtained by the investigation of the protein synthesis.

  9. Report of two cases of fluorodeoxyglucose positron emission tomography/computed tomography appearance of hibernoma: A rare benign tumor

    International Nuclear Information System (INIS)

    Agrawal, Archi; Kembhavi, Seema; Purandare, Nilendu; Shah, Sneha; Rangarajan, Venkatesh

    2014-01-01

    False-positive findings are commonly seen in positron emission tomography computed tomography imaging. One of the most common false positive finding is uptake of fluorodeoxyglucose in brown adipose tissue. Herein, we report two cases with incidentally detected hibernomas-a brown fat containing tumor with metabolic activity

  10. Unusual sites of metastatic recurrence of osteosarcoma detected on fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Kabnurkar, Rasika; Agrawal, Archi; Rekhi, Bharat; Purandare, Nilendu; Shah, Sneha; Rangarajan, Venkatesh

    2015-01-01

    Osteosarcoma (OS) is the most common nonhematolymphoid primary bone malignancy characterized by osteoid or new bone formation. Lungs and bones are the most common sites of metastases. We report a case where unusual sites of the soft tissue recurrence from OS were detected on restaging fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography scan done post 6 years of disease free interval

  11. The value of positron emission tomography/computed tomography for evaluating metastatic disease in patients with pancreatic cancer.

    Science.gov (United States)

    Kim, Mi-Jin; Lee, Kwang Hyuck; Lee, Kyu Taek; Lee, Jong Kyun; Ku, Bon-Ho; Oh, Cho-Rong; Heo, Jin Seok; Choi, Seong-Ho; Choi, Dong Wook

    2012-08-01

    Routine application of positron emission tomography/computed tomography (PET/CT) for pancreatic cancer staging remains a controversial approach. The purpose of this study was to reassess the clinical impact of PET/CT for the detection of distant metastasis of pancreatic cancer. From January 2006 to June 2009, 125 patients with histologically proven pancreatic cancer that had undergone PET/CT at our hospital were retrospectively reviewed. To evaluate the clinical efficacy of PET/CT on the management plan, the post-PET/CT management plans were compared with the pre-PET/CT management plans. After the conventional staging workup, we determined that 76 patients (60.8%) had resectable lesions, whereas 48 patients had unresectable lesions. One patient underwent explorative laparotomy due to equivocal resectability. Positron emission tomography/computed tomography diagnosed distant metastasis in only 2 (2.6%) of the 76 patients with resectable lesions, and these patients did not undergo unnecessary surgical treatment. Complete resection was not performed in 8 of the 74 operative patients because they had distant metastasis detected during the operative procedure. Positron emission tomography/computed tomography diagnosed distant metastasis in 32 of the 44 patients with metastatic lesions that were histologically shown to have sensitivity of 72.7%. Positron emission tomography/computed tomography has a limited role in the evaluation of metastatic disease from pancreatic cancer.

  12. Incidental head and neck findings on 18F-fluoro-deoxy-glucose positron emission tomography computed tomography.

    Science.gov (United States)

    Williams, S P; Kinshuck, A J; Williams, C; Dwivedi, R; Wieshmann, H; Jones, T M

    2015-09-01

    The overlapping risk factors for lung and head and neck cancer present a definite risk of synchronous malignant pathology. This is the first study to specifically review incidental positron emission tomography computed tomography findings in the head and neck region in lung carcinoma patients. A retrospective review was performed of all lung cancer patients who underwent positron emission tomography computed tomography imaging over a five-year period (January 2008 - December 2012), identified from the Liverpool thoracic multidisciplinary team database. Six hundred and nine patients underwent positron emission tomography computed tomography imaging over this period. In 76 (12.5 per cent) scans, incidental regions of avid 18F-fluoro-deoxy-glucose uptake were reported in the head and neck region. In the 28 patients who were fully investigated, there were 4 incidental findings of malignancy. In lung cancer patients undergoing investigative positron emission tomography computed tomography scanning, a significant number will also present with areas of clinically significant 18F-fluoro-deoxy-glucose uptake in the head and neck region. Of these, at least 5 per cent may have an undiagnosed malignancy.

  13. Extensive tumor thrombus of hepatocellular carcinoma in the entire portal venous system detected on fluorodeoxyglucose positron emission tomography computed tomography

    International Nuclear Information System (INIS)

    Agrawal, Archi; Purandare, Nilendu; Shah, Sneha; Puranik, Ameya; Rangarajan, Venkatesh

    2013-01-01

    Detection of thrombus is usually an incidental finding on fluorodeoxyglucose positron emission tomography/computed tomography studies. Nevertheless this is an important finding in terms of disease prognostication and in planning the treatment strategy. We herein report a case of a 50-years-old male, a diagnosed case of hepatocellular carcinoma with extensive hypermetabolic thrombus involving the entire portal venous system. (author)

  14. Diagnosis of sinusoidal obstruction syndrome by positron emission tomography/computed tomography: report of two cases treated by defibrotide.

    Science.gov (United States)

    Gauthé, Mathieu; Bozec, Laurence; Bedossa, Pierre

    2014-11-01

    Sinusoidal obstruction syndrome (SOS) is a potentially fatal liver injury that mainly occurs after myeloablative chemotherapy. We report two cases of SOS investigated by 18F-fluorodeoxyglucose positron emission tomography/computed tomography and treated with defibrotide. © 2014 by the American Association for the Study of Liver Diseases.

  15. X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.

    Science.gov (United States)

    Kinahan, Paul E; Hasegawa, Bruce H; Beyer, Thomas

    2003-07-01

    A synergy of positron emission tomography (PET)/computed tomography (CT) scanners is the use of the CT data for x-ray-based attenuation correction of the PET emission data. Current methods of measuring transmission use positron sources, gamma-ray sources, or x-ray sources. Each of the types of transmission scans involves different trade-offs of noise versus bias, with positron transmission scans having the highest noise but lowest bias, whereas x-ray scans have negligible noise but the potential for increased quantitative errors. The use of x-ray-based attenuation correction, however, has other advantages, including a lack of bias introduced from post-injection transmission scanning, which is an important practical consideration for clinical scanners, as well as reduced scan times. The sensitivity of x-ray-based attenuation correction to artifacts and quantitative errors depends on the method of translating the CT image from the effective x-ray energy of approximately 70 keV to attenuation coefficients at the PET energy of 511 keV. These translation methods are usually based on segmentation and/or scaling techniques. Errors in the PET emission image arise from positional mismatches caused by patient motion or respiration differences between the PET and CT scans; incorrect calculation of attenuation coefficients for CT contrast agents or metallic implants; or keeping the patient's arms in the field of view, which leads to truncation and/or beam-hardening (or x-ray scatter) artifacts. Proper interpretation of PET emission images corrected for attenuation by using the CT image relies on an understanding of the potential artifacts. In cases where an artifact or bias is suspected, careful inspection of all three available images (CT and PET emission with and without attenuation correction) is recommended. Copyright 2003 Elsevier Inc. All rights reserved.

  16. Use of Computed Tomography and Positron Emission Tomography/Computed Tomography for Staging of Local Extent in Patients With Malignant Pleural Mesothelioma

    OpenAIRE

    Frauenfelder, Thomas; Kestenholz, Peter; Hunziker, Roger; Nguyen, Thi Dan Linh; Fries, Martina; Veit-Haibach, Patrick; Husmann, Lars; Stahel, Rolf; Weder, Walter; Opitz, Isabelle

    2015-01-01

    PURPOSE The objective of this study was to determine the diagnostic value of computed tomography (CT) and positron emission tomography (PET)/CT for staging of malignant pleural mesothelioma (MPM) in patients undergoing induction chemotherapy. METHODS Sixty-two patients (median age, 61 years; female: n = 9) with proven MPM underwent CT after induction chemotherapy. Of these, 28 underwent additional PET/CT. Extrapleural pneumonectomy was performed for pathological TNM staging. Clinical TNM s...

  17. Roles of computed tomography and [18F]fluorodeoxyglucose-positron emission tomography/computed tomography in the characterization of multiple solitary solid lung nodules

    OpenAIRE

    Travaini, LL; Trifirò, G; Vigna, PD; Veronesi, G; De Pas, TM; Spaggiari, L; Paganelli, G; Bellomi, M

    2012-01-01

    The purpose of this study is to compare the performance of multidetector computed tomography (CT) and positron emission tomography/CT (PET/CT) with [18F]fluorodeoxyglucose in the diagnosis of multiple solitary lung nodules in 14 consecutive patients with suspicious lung cancer. CT and PET/CT findings were reviewed by a radiologist and nuclear medicine physician, respectively, blinded to the pathological diagnoses of lung cancer, considering nodule size, shape, and location (CT) and maximum st...

  18. Single photon emission tomography

    International Nuclear Information System (INIS)

    Buvat, Irene

    2011-09-01

    The objective of this lecture is to present the single photon emission computed tomography (SPECT) imaging technique. Content: 1 - Introduction: anatomic, functional and molecular imaging; Principle and role of functional or molecular imaging; 2 - Radiotracers: chemical and physical constraints, main emitters, radioisotopes production, emitters type and imaging techniques; 3 - Single photon emission computed tomography: gamma cameras and their components, gamma camera specifications, planar single photon imaging characteristics, gamma camera and tomography; 4 - Quantification in single photon emission tomography: attenuation, scattering, un-stationary spatial resolution, partial volume effect, movements, others; 5 - Synthesis and conclusion

  19. Detection of non-aggressive stage IA lung cancer using chest computed tomography and positron emission tomography/computed tomography.

    Science.gov (United States)

    Shiono, Satoshi; Yanagawa, Naoki; Abiko, Masami; Sato, Toru

    2014-10-01

    In contrast to lung cancer with ground-glass opacity, the radiological investigation of solid lung cancer has not been well examined. The aim of this study was to explore chest computed tomography (CT) and positron emission tomography (PET)/CT findings with regard to outcomes after lung cancer surgery in order to radiologically classify clinical stage IA lung cancers by tumour aggressiveness. Three hundred and fifteen clinical stage IA patients were analysed. Four groups were defined by tumour solidity on CT and by the standardized uptake value (SUV) index on PET-CT (tumour maximum SUV/mean right liver lobe SUV). We analysed the association between radiological findings and both pathological invasiveness and postoperative outcome. Group A (n = 84) had an SUV index <1.0 and non-solid tumours, Group B (n = 24) had an SUV index <1.0 and solid tumours, Group C (n = 54) had an SUV index ≥1.0 and non-solid tumours, while Group D (n = 153) had an SUV index ≥1.0 and solid tumours. Invasive lung cancer was found in 2/84 (2.4%) patients in Group A, 1/24 (4.2%) in Group B, 13/54 (24.1%) in Group C and 58/153 (37.9%) in Group D (P < 0.01). The 5-year recurrence-free rate was 100% in Groups A and B, 90.3% in C and 65.7% in D (P < 0.01). The cancer-specific survival rate was 100% in A and B, 94.6% in C and 81.7% in D (P < 0.01). The present results suggest that preoperative PET/CT and thin-section CT findings provide important information for a selection of surgical procedures for clinical stage IA lung cancers. In clinical stage IA lung cancers displaying solid or non-solid density in thin-section findings, an SUV index <1.0 may be a better criterion for detecting non-aggressive lung cancer even in solid lung cancers. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  20. Computed tomography

    International Nuclear Information System (INIS)

    Wells, P.; Davis, J.; Morgan, M.

    1994-01-01

    X-ray or gamma-ray transmission computed tomography (CT) is a powerful non-destructive evaluation (NDE) technique that produces two-dimensional cross-sectional images of an object without the need to physically section it. CT is also known by the acronym CAT, for computerised axial tomography. This review article presents a brief historical perspective on CT, its current status and the underlying physics. The mathematical fundamentals of computed tomography are developed for the simplest transmission CT modality. A description of CT scanner instrumentation is provided with an emphasis on radiation sources and systems. Examples of CT images are shown indicating the range of materials that can be scanned and the spatial and contrast resolutions that may be achieved. Attention is also given to the occurrence, interpretation and minimisation of various image artefacts that may arise. A final brief section is devoted to the principles and potential of a range of more recently developed tomographic modalities including diffraction CT, positron emission CT and seismic tomography. 57 refs., 2 tabs., 14 figs

  1. Image reconstruction from projections and its application in emission computer tomography

    International Nuclear Information System (INIS)

    Kuba, Attila; Csernay, Laszlo

    1989-01-01

    Computer tomography is an imaging technique for producing cross sectional images by reconstruction from projections. Its two main branches are called transmission and emission computer tomography, TCT and ECT, resp. After an overview of the theory and practice of TCT and ECT, the first Hungarian ECT type MB 9300 SPECT consisting of a gamma camera and Ketronic Medax N computer is described, and its applications to radiological patient observations are discussed briefly. (R.P.) 28 refs.; 4 figs

  2. Occult primary tumors of the head and neck: accuracy of thallium 201 single-photon emission computed tomography and computed tomography and/or magnetic resonance imaging

    NARCIS (Netherlands)

    van Veen, S. A.; Balm, A. J.; Valdés Olmos, R. A.; Hoefnagel, C. A.; Hilgers, F. J.; Tan, I. B.; Pameijer, F. A.

    2001-01-01

    To determine the accuracy of thallium 201 single-photon emission computed tomography (thallium SPECT) and computed tomography and/or magnetic resonance imaging (CT/MRI) in the detection of occult primary tumors of the head and neck. Study of diagnostic tests. National Cancer Institute, Amsterdam,

  3. Positron emission tomography/computed tomography surveillance in patients with Hodgkin lymphoma in first remission has a low positive predictive value and high costs.

    Science.gov (United States)

    El-Galaly, Tarec Christoffer; Mylam, Karen Juul; Brown, Peter; Specht, Lena; Christiansen, Ilse; Munksgaard, Lars; Johnsen, Hans Erik; Loft, Annika; Bukh, Anne; Iyer, Victor; Nielsen, Anne Lerberg; Hutchings, Martin

    2012-06-01

    The value of performing post-therapy routine surveillance imaging in patients with Hodgkin lymphoma is controversial. This study evaluates the utility of positron emission tomography/computed tomography using 2-[18F]fluoro-2-deoxyglucose for this purpose and in situations with suspected lymphoma relapse. We conducted a multicenter retrospective study. Patients with newly diagnosed Hodgkin lymphoma achieving at least a partial remission on first-line therapy were eligible if they received positron emission tomography/computed tomography surveillance during follow-up. Two types of imaging surveillance were analyzed: "routine" when patients showed no signs of relapse at referral to positron emission tomography/computed tomography, and "clinically indicated" when recurrence was suspected. A total of 211 routine and 88 clinically indicated positron emission tomography/computed tomography studies were performed in 161 patients. In ten of 22 patients with recurrence of Hodgkin lymphoma, routine imaging surveillance was the primary tool for the diagnosis of the relapse. Extranodal disease, interim positron emission tomography-positive lesions and positron emission tomography activity at response evaluation were all associated with a positron emission tomography/computed tomography-diagnosed preclinical relapse. The true positive rates of routine and clinically indicated imaging were 5% and 13%, respectively (P = 0.02). The overall positive predictive value and negative predictive value of positron emission tomography/computed tomography were 28% and 100%, respectively. The estimated cost per routine imaging diagnosed relapse was US$ 50,778. Negative positron emission tomography/computed tomography reliably rules out a relapse. The high false positive rate is, however, an important limitation and a confirmatory biopsy is mandatory for the diagnosis of a relapse. With no proven survival benefit for patients with a pre-clinically diagnosed relapse, the high costs and low

  4. Detecting Metastatic Bladder Cancer Using (18)F-Fluorodeoxyglucose Positron-Emission Tomography/Computed Tomography.

    Science.gov (United States)

    Öztürk, Hakan

    2015-10-01

    The purpose of this study was to retrospectively investigate the contribution of (18)F-fluorodeoxyglucose-positron emission tomography/computed tomography ((18)F-FDG-PET/CT) to detection of metastatic bladder cancer. The present study included 79 patients (69 men and 10 women) undergoing (18)F-FDG-PET/CT upon suspicion of metastatic bladder cancer between July 2007 and April 2013. The mean age was 66.1 years with a standard deviation of 10.7 years (range, 21 to 85 years). Patients were required to fast for 6 hours prior to scanning, and whole-body PET scanning from the skull base to the upper thighs was performed approximately 1 hour after intravenous injection of 555 MBq of (18)F-FDG. Whole body CT scanning was performed in the cranio-caudal direction. FDG-PET images were reconstructed using CT data for attenuation correction. Suspicious recurrent or metastatic lesions were confirmed by histopathology or clinical follow-up. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of (18)F-FDG-PET/CT were 89%, 78%, 90%, 75%, and 86%, respectively. (18)F-FDG-PET/CT can detect metastases with high sensitivity and positive predictive values in patients with metastatic bladder carcinoma.

  5. Brain Positron Emission Tomography-Computed Tomography Gender Differences in Tinnitus Patients.

    Science.gov (United States)

    Shlamkovich, Nathan; Gavriel, Haim; Eviatar, Ephraim; Lorberboym, Mordechay; Aviram, Eliad

    2016-10-01

    Increased metabolism in the left auditory cortex has been reported in tinnitus patients. However, gender difference has not been addressed. To assess the differences in Positron emission tomography-computed tomography (PET-CT) results between the genders in tinnitus patients. Retrospective cohort. Included were patients referred to our clinic between January 2011 and August 2013 who complained of tinnitus and underwent fluorodeoxyglucose (FDG)-PET to assess brain metabolism. Univariate and multivariate nominal logistic regressions were used to evaluate the association between upper temporal gyrus (UTG; right and left) and gender. Included were 140 patients (87 males) with an average age of 52.5 yr (median = 53.1). Bilateral tinnitus was found in 85 patients (60.7%), left sided in 30 (21.4%), and right sided in 21(15%). Increased uptake in the UTG was found in 60% of the patients on either side. Males had a statistically significant increased uptake in the UTG in those with unilateral tinnitus and in the entire population. We present the largest study reported so far on tinnitus patients who have undergone FDG-PET-CT. We found a statistically significant difference between the genders in FDG uptake by the UTG. Further investigations should be undertaken to reveal the etiologies for these differences and to assess different therapeutic protocols according to gender. American Academy of Audiology

  6. Use of Positron Emission Tomography/Computed Tomography in Radiation Treatment Planning for Lung Cancer

    Directory of Open Access Journals (Sweden)

    Kezban Berberoğlu

    2016-06-01

    Full Text Available Radiotherapy (RT plays an important role in the treatment of lung cancer. Accurate diagnosis and staging are crucial in the delivery of RT with curative intent. Target miss can be prevented by accurate determination of tumor contours during RT planning. Currently, tumor contours are determined manually by computed tomography (CT during RT planning. This method leads to differences in delineation of tumor volume between users. Given the change in RT tools and methods due to rapidly developing technology, it is now more significant to accurately delineate the tumor tissue. F18 fluorodeoxyglucose positron emission tomography/CT (F18 FDG PET/CT has been established as an accurate method in correctly staging and detecting tumor dissemination in lung cancer. Since it provides both anatomic and biologic information, F18 FDG PET decreases interuser variability in tumor delineation. For instance, tumor volumes may be decreased as atelectasis and malignant tissue can be more accurately differentiated, as well as better evaluation of benign and malignant lymph nodes given the difference in FDG uptake. Using F18 FDG PET/CT, the radiation dose can be escalated without serious adverse effects in lung cancer. In this study, we evaluated the contribution of F18 FDG PET/CT for RT planning in lung cancer.

  7. 18F-FDG positron emission tomography/computed tomography in infective endocarditis.

    Science.gov (United States)

    Salomäki, Soile Pauliina; Saraste, Antti; Kemppainen, Jukka; Bax, Jeroen J; Knuuti, Juhani; Nuutila, Pirjo; Seppänen, Marko; Roivainen, Anne; Airaksinen, Juhani; Pirilä, Laura; Oksi, Jarmo; Hohenthal, Ulla

    2017-02-01

    The diagnosis of infective endocarditis (IE), especially the diagnosis of prosthetic valve endocarditis (PVE) is challenging since echocardiographic findings are often scarce in the early phase of the disease. We studied the use of 2-[ 18 F]fluoro-2-deoxy-D-glucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) in IE. Sixteen patients with suspected PVE and 7 patients with NVE underwent visual evaluation of 18 F-FDG-PET/CT. 18 F-FDG uptake was measured also semiquantitatively as maximum standardized uptake value (SUV max ) and target-to-background ratio (TBR). The modified Duke criteria were used as a reference. There was strong, focal 18 F-FDG uptake in the area of the affected valve in all 6 cases of definite PVE, in 3 of 5 possible PVE cases, and in 2 of 5 rejected cases. In all patients with definite PVE, SUV max of the affected valve was higher than 4 and TBR higher than 1.8. In contrast to PVE, only 1 of 7 patients with NVE had uptake of 18 F-FDG by PET/CT in the valve area. Embolic infectious foci were detected in 58% of the patients with definite IE. 18 F-FDG-PET/CT appears to be a sensitive method for the detection of paravalvular infection associated with PVE. Instead, the sensitivity of PET/CT is limited in NVE.

  8. Mycosis fungoides: Positron emission tomography/computed tomography in staging and monitoring the effect of therapy

    International Nuclear Information System (INIS)

    D’Souza, Maria Mathew; D’Souza, Paschal; Sharma, Rajnish; Jaimini, Abhinav; Mondal, Anupam

    2015-01-01

    A 58-year-old woman, diagnosed as a case of mycosis fungoides (MF), underwent [18F]-fluoro-D-glucose positron emission tomography/computed tomography (FDG PET/CT) examination. The study revealed intense FDG uptake in a large ulceroproliferative right thigh lesion, indurated plaques in the chest wall and left thigh, along with multiple sites of cutaneous involvement, axillary and inguinal lymphadenopathy. The patient underwent chemotherapy with CHOP regimen, radiotherapy for the right thigh lesion, along with topical corticosteroids and emollients for the disseminated cutaneous involvement. Repeat [18F]-FDG PET/CT study performed a year later, showed near complete disease regression specifically of the ulceroproliferative lesion and indurated cutaneous plaques, no change in lymphadenopathy, and a subtle diffuse progression of the remaining cutaneous lesions. A multidisciplinary approach to the diagnosis, staging and treatment of MF has long been suggested for optimizing outcomes from management of patients with this disease. This case highlights the potential role of incorporating PET/CT as a single modality imaging technique in the staging and assessment of response to therapy

  9. Technical aspects of positron emission tomography/computed tomography in radiotherapy treatment planning.

    Science.gov (United States)

    Scripes, Paola G; Yaparpalvi, Ravindra

    2012-09-01

    The usage of functional data in radiation therapy (RT) treatment planning (RTP) process is currently the focus of significant technical, scientific, and clinical development. Positron emission tomography (PET) using ((18)F) fluorodeoxyglucose is being increasingly used in RT planning in recent years. Fluorodeoxyglucose is the most commonly used radiotracer for diagnosis, staging, recurrent disease detection, and monitoring of tumor response to therapy (Lung Cancer 2012;76:344-349; Lung Cancer 2009;64:301-307; J Nucl Med 2008;49:532-540; J Nucl Med 2007;48:58S-67S). All the efforts to improve both PET and computed tomography (CT) image quality and, consequently, lesion detectability have a common objective to increase the accuracy in functional imaging and thus of coregistration into RT planning systems. In radiotherapy, improvement in target localization permits reduction of tumor margins, consequently reducing volume of normal tissue irradiated. Furthermore, smaller treated target volumes create the possibility of dose escalation, leading to increased chances of tumor cure and control. This article focuses on the technical aspects of PET/CT image acquisition, fusion, usage, and impact on the physics of RTP. The authors review the basic elements of RTP, modern radiation delivery, and the technical parameters of coregistration of PET/CT into RT computerized planning systems. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. SPECT: Theoretical aspecte and evolution of emission computed axial tomography

    International Nuclear Information System (INIS)

    Brunol, J.; Nuta, V.

    1981-01-01

    We have detailed certain of the elements of 3-D image reconstruction from axial projections. Two of the aspects specific to nuclear medicine have been analysed namely self-absorption and statistics. In our view, the development of ECAT in the months to come must hence proceed in two essential directions: - application to dynamic cardiac imagery (multigated). Results of this type have been obtained over 8 months in the Radioisotope Service of Cochin Hospital in Paris. It must be stressed here that the number of images to be processed then becomes considerable (multiplication by the gate factor yielding more than 100 images), the more the statistics are reduced due to the fact of the temporal separation. The obtaining of good image quality requires sophisticated quadri-dimensional processing. It follows that the computing times, with all the mini-computers available in nuclear medicine, then become much too great to envisage really application in hospital routine (several hours of computing). This is the reason why we connected an array processor with the IMAC system. This very powerful system (several tens of times the power of a mini-computer) will reduce the time of such computing to less than 10 minutes. New elements can be introduced into the reconstruction algorithm (static case opposite the foregoing one). These important elements of improvement are to the detriment of space and hence of computing time. Here again, the use of an array processor appears indispensable. It is to recall that the ECAT is today a currently used method, the theoretical analyses that it has necessitated have opened the way to new effective methods of tomography by 'Slanted Hole'. (orig.) [de

  11. 18 F-fluorodeoxyglucose positron emission tomography-computed tomography for preoperative lymph node staging in patients undergoing radical cystectomy for bladder cancer: a prospective study.

    Science.gov (United States)

    Hitier-Berthault, Maryam; Ansquer, Catherine; Branchereau, Julien; Renaudin, Karine; Bodere, Françoise; Bouchot, Olivier; Rigaud, Jérôme

    2013-08-01

    The objective of our study was to analyze the diagnostic performance of (18) F-fluorodeoxyglucose positron emission tomography-computed tomography for lymph node staging in patients with bladder cancer before radical cystectomy and to compare it with that of computed tomography. A total of 52 patients operated on between 2005 and 2010 were prospectively included in this prospective, mono-institutional, open, non-randomized pilot study. Patients who had received neoadjuvant chemotherapy or radiotherapy were excluded. (18) F-fluorodeoxyglucose positron emission tomography-computed tomography in addition to computed tomography was carried out for lymph node staging of bladder cancer before radical cystectomy. Lymph node dissection during radical cystectomy was carried out. Findings from (18) F-fluorodeoxyglucose positron emission tomography-computed tomography and computed tomography were compared with the results of definitive histological examination of the lymph node dissection. The diagnostic performance of the two imaging modalities was assessed and compared. The mean number of lymph nodes removed during lymph node dissection was 16.5 ± 10.9. Lymph node metastasis was confirmed on histological examination in 22 cases (42.3%). This had been suspected in five cases (9.6%) on computed tomography and in 12 cases (23.1%) on (18) F-fluorodeoxyglucose positron emission tomography-computed tomography. Sensitivity, specificity, positive predictive value, negative predictive value, relative risk and accuracy were 9.1%, 90%, 40%, 57.4%, 0.91 and 55.7%, respectively, for computed tomography, and 36.4%, 86.7%, 66.7%, 65%, 2.72, 65.4%, respectively, for (18) F-fluorodeoxyglucose positron emission tomography-computed tomography. (18) F-fluorodeoxyglucose positron emission tomography-computed tomography is more reliable than computed tomography for preoperative lymph node staging in patients with invasive bladder carcinoma undergoing radical cystectomy. © 2012 The Japanese

  12. Emission computer tomography on a Dodewaard mixed oxide fuel pin

    International Nuclear Information System (INIS)

    Buurveld, H.A.; Dassel, G.

    1993-12-01

    A nondestructive technique as well as a destructive PIE technique have been used to verify the results obtained with a newly 8-e computer tomography (GECT) system. Multi isotope Scanning (MIS), electron probe micro analysis (EPMA) and GECT were used on a mixed oxide (MOX) fuel rod from the Dodewaard reactor with an average burnup of 24 MWd/kg fuel. GECT shows migration of Cs to the periphery of fuel pellets and to radial cracks and pores in the fuel, whereas MIS shows Cs migration to pellet interfaces. The EPMA technique appeared not to be useful to show migration of Cs but, it shows the distribution of fission products from Pu. EPMA clearly shows the distribution of fission products from Pu, but did not reveal the Cs-migration. (orig./HP)

  13. The contribution of single photon emission computed tomography in the clinical assessment of Alzheimer type dementia

    International Nuclear Information System (INIS)

    Boudousq, V.; Collombier, L.; Kotzki, P.O.

    1999-01-01

    Interest of brain single-photon emission computed tomography to support clinical diagnosis of Alzheimer-type dementia is now established. Numerous studies have reported a decreased perfusion in the association cortex of the parietal lobe and the posterior temporal regions. In patients with mild cognitive complaints, the presence of focal hypoperfusion may increase substantially the probability of the disease. In addition, emission tomography emerges as a helpful tool in situation in which there is diagnostic doubt. In this case, the presence of temporo-parietal perfusion deficit associated with hippocampal atrophy on MRI or X-ray computed tomography contributes to diagnostic accuracy. However, some studies suggest that emission tomography may be useful for preclinical prediction of Alzheimer's disease and to predict cognitive decline. (author)

  14. A general class of preconditioners for statistical iterative reconstruction of emission computed tomography

    International Nuclear Information System (INIS)

    Chinn, G.; Huang, S.C.

    1997-01-01

    A major drawback of statistical iterative image reconstruction for emission computed tomography is its high computational cost. The ill-posed nature of tomography leads to slow convergence for standard gradient-based iterative approaches such as the steepest descent or the conjugate gradient algorithm. In this paper new theory and methods for a class of preconditioners are developed for accelerating the convergence rate of iterative reconstruction. To demonstrate the potential of this class of preconditioners, a preconditioned conjugate gradient (PCG) iterative algorithm for weighted least squares reconstruction (WLS) was formulated for emission tomography. Using simulated positron emission tomography (PET) data of the Hoffman brain phantom, it was shown that the convergence rate of the PCG can reduce the number of iterations of the standard conjugate gradient algorithm by a factor of 2--8 times depending on the convergence criterion

  15. Retroperitoneal Endometriosis: A Possible Cause of False Positive Finding at 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography

    International Nuclear Information System (INIS)

    Maffione, Anna Margherita; Panzavolta, Riccardo; Lisato, Laura Camilla; Ballotta, Maria; D'Isanto, Mariangela Zanforlini; Rubello, Domenico

    2015-01-01

    Endometriosis is a frequent and clinically relevant problem in young women. Laparoscopy is still the gold standard for the diagnosis of endometriosis, but frequently both morphologic and functional imaging techniques are involved in the diagnostic course before achieving a conclusive diagnosis. We present a case of a patient affected by infiltrating retroperitoneal endometriosis falsely interpreted as a malignant mass by contrast-enhanced magnetic resonance imaging and 18 F-fluorodeoxyglucose positron emission tomography/computed tomography

  16. Utility of fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography in a child with chronic granulomatous disease

    International Nuclear Information System (INIS)

    Garg, Gunjan; DaSilva, Raphaella; Bhalakia, Avni; Milstein, David M.

    2016-01-01

    We report the fluorodeoxyglucose positron emission tomography/computed tomography (FDG - PET/CT) findings in an 11-month-old boy with suspected milk protein allergy, presented to the hospital with 2-month history of fever of unknown origin and failure to thrive. It showed FDG avid lymphadenopathy above and below the diaphragm and splenic focus, which could represent diffuse inflammatory process or lymphoma. Subsequent jejunal biopsy showed non-necrotizing granulomas

  17. Head and neck: normal variations and benign findings in FDG positron emission tomography/computed tomography imaging.

    Science.gov (United States)

    Højgaard, Liselotte; Berthelsen, Anne Kiil; Loft, Annika

    2014-04-01

    Positron emission tomography (PET)/computed tomography with FDG of the head and neck region is mainly used for the diagnosis of head and neck cancer, for staging, treatment evaluation, relapse, and planning of surgery and radio therapy. This article is a practical guide of imaging techniques, including a detailed protocol for FDG PET in head and neck imaging, physiologic findings, and pitfalls in selected case stories. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. EEG, transmission computed tomography, and positron emission tomography with fluorodeoxyglucose 18F. Their use in adults with gliomas

    International Nuclear Information System (INIS)

    Newmark, M.E.; Theodore, W.H.; Sato, S.; De La Paz, R.; Patronas, N.; Brooks, R.; Jabbari, B.; Di Chiro, G.

    1983-01-01

    We evaluated the relationship between findings from EEG, transmission computed tomography (CT), and positron emission tomography in 23 adults with gliomas. The cortical metabolic rate was suppressed in patients with and without focal slowing. Focal delta activity was not related to involvement of gray or white matter. Rhythmic delta activity and focal attenuation of background amplitude on EEG, however, were correlated with involvement of the thalamus

  19. Patterns of brown fat uptake of 18F-fluorodeoxyglucose in positron emission tomography/computed tomography scan

    International Nuclear Information System (INIS)

    Chakraborty, Dhritiman; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2015-01-01

    Fluorodeoxyglucose (FDG) positron emission tomography (PET) has become the common imaging modality in oncological practice. FDG uptake is seen in brown adipose tissue in a significant number of patients. Recognizing the uptake patterns is important for optimal FDG PET interpretation. The introduction of PET/computed tomography (PET/CT) revolutionized PET imaging, bringing much-needed anatomical information. Careful review and correlation of FDG PET images with anatomical imaging should be performed to characterize accurately any lesion having high FDG uptake

  20. In Vivo Treatment Sensitivity Testing With Positron Emission Tomography/Computed Tomography After One Cycle of Chemotherapy for Hodgkin Lymphoma

    DEFF Research Database (Denmark)

    Hutchings, Martin; Kostakoglu, Lale; Zaucha, Jan Maciej

    2014-01-01

    PURPOSE: Negative [(18)F]fluorodeoxyglucose (FDG) -positron emission tomography (PET)/computed tomography (CT) after two cycles of chemotherapy indicates a favorable prognosis in Hodgkin lymphoma (HL). We hypothesized that the negative predictive value would be even higher in patients responding....... In the absence of precise pretherapeutic predictive markers, PET1 is the best method for response-adapted strategies designed to select patients for less intensive treatment....

  1. Trails on 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Leading to Diagnosis of Testicular Adrenal Rest Tumor.

    Science.gov (United States)

    Kashyap, Raghava

    2018-01-01

    Testicular adrenal rest tumors (TARTs) are secondary to hypertrophy of adrenal rest cells in the rete testis in settings of hypersecretion of androgens. We present a case of congenital adrenal hyperplasia with TART with clues to the diagnosis on 18 F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT). To the best of our knowledge, this is the first reported case on the role of 18 F-FDG PET/CT in TART.

  2. ¹⁸F-fluorodeoxyglucose positron emission tomography-computed tomography for the evaluation of bone metastasis in patients with gastric cancer.

    Science.gov (United States)

    Ma, Dae Won; Kim, Jie-Hyun; Jeon, Tae Joo; Lee, Yong Chan; Yun, Mijin; Youn, Young Hoon; Park, Hyojin; Lee, Sang In

    2013-09-01

    The roles of positron emission tomography and bone scanning in identifying bone metastasis in gastric cancer are unclear. We compared the usefulness of positron emission tomography-computed tomography and scanning in detecting bone metastasis in gastric cancer. Data from 1485 patients diagnosed with gastric cancer who had undergone positron emission tomography-computed tomography and scanning were reviewed. Of 170 enrolled patients who were suspected of bone metastasis in either positron emission tomography or scanning, 81.2% were confirmed to have bone metastasis. The sensitivity, specificity, and accuracy were 93.5%, 25.0%, and 80.6%, respectively, for positron emission tomography and 93.5%, 37.5%, and 82.9%, respectively, for scanning. 87.7% of patients with bone metastasis showed positive findings on two modalities. 15.0% of solitary bone metastases were positive on positron emission tomography only. Positron emission tomography was superior to scanning for the detection of synchronous bone metastasis, but the two modalities were similar for the detection of metachronous bone metastasis. The concordance rate of response assessment after treatment between two modalities was moderate. Positron emission tomography-computed tomography may be more effective for the diagnosis of bone metastasis in the initial staging workup. Conversely, bone scanning and positron emission tomography-computed tomography may be similarly effective for the detection of metachronous bone metastasis. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  3. Computed tomography and (18)F-fluorodeoxyglucose positron emission tomography/computed tomography findings in adrenal candidiasis and histoplasmosis: two cases.

    Science.gov (United States)

    Altinmakas, Emre; Guo, Ming; Kundu, Uma R; Habra, Mouhammed Amir; Ng, Chaan

    2015-01-01

    We report the contrast-enhanced computed tomography (CT) and (18)F-fluorodeoxyglucose positron emission tomography findings in adrenal histoplasmosis and candidiasis. Both demonstrated bilateral hypermetabolic heterogeneous adrenal masses with limited wash-out on delayed CT. Adrenal candidiasis has not been previously reported, nor have the CT wash-out findings in either infection. The adrenal imaging findings are indistinguishable from malignancy, which is more common; but in this setting, physicians should be alert to the differential diagnosis of fungal infections, since it can be equally deadly. Published by Elsevier Inc.

  4. Relationship of computed tomography perfusion and positron emission tomography to tumour progression in malignant glioma

    Energy Technology Data Exchange (ETDEWEB)

    Yeung, Timothy P C [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Robarts Research Institute, The University of Western Ontario, Ontario, Canada, N6A 5B7 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Yartsev, Slav [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Lee, Ting-Yim [Robarts Research Institute, The University of Western Ontario, Ontario, Canada, N6A 5B7 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Department of Medical Imaging, The University of Western Ontario, London Health Sciences Centre, Victoria Hospital, Ontario, Canada, N6A 5W9 (Australia); Lawson Health Research Institute, St. Joseph' s Health Care London, Ontario, Canada, N6A 4V2 (Canada); Wong, Eugene [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Department of Physics and Astronomy, The University of Western Ontario, Ontario, Canada, N6A 3K7 (Canada); He, Wenqing [Department of Statistical and Actuarial Sciences, The University of Western Ontario, Ontario, Canada, N6A 5B7 (Canada); Fisher, Barbara; VanderSpek, Lauren L [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Macdonald, David [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Department of Clinical Neurological Sciences, The University of Western Ontario, London Health Sciences Centre, University Hospital, Ontario, Canada, N6A 5A5 (Canada); Bauman, Glenn, E-mail: glenn.bauman@lhsc.on.ca [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada)

    2014-02-15

    Introduction: This study aimed to explore the potential for computed tomography (CT) perfusion and 18-Fluorodeoxyglucose positron emission tomography (FDG-PET) in predicting sites of future progressive tumour on a voxel-by-voxel basis after radiotherapy and chemotherapy. Methods: Ten patients underwent pre-radiotherapy magnetic resonance (MR), FDG-PET and CT perfusion near the end of radiotherapy and repeated post-radiotherapy follow-up MR scans. The relationships between these images and tumour progression were assessed using logistic regression. Cross-validation with receiver operating characteristic (ROC) analysis was used to assess the value of these images in predicting sites of tumour progression. Results: Pre-radiotherapy MR-defined gross tumour; near-end-of-radiotherapy CT-defined enhancing lesion; CT perfusion blood flow (BF), blood volume (BV) and permeability-surface area (PS) product; FDG-PET standard uptake value (SUV); and SUV:BF showed significant associations with tumour progression on follow-up MR imaging (P < 0.0001). The mean sensitivity (±standard deviation), specificity and area under the ROC curve (AUC) of PS were 0.64 ± 0.15, 0.74 ± 0.07 and 0.72 ± 0.12 respectively. This mean AUC was higher than that of the pre-radiotherapy MR-defined gross tumour and near-end-of-radiotherapy CT-defined enhancing lesion (both AUCs = 0.6 ± 0.1, P ≤ 0.03). The multivariate model using BF, BV, PS and SUV had a mean AUC of 0.8 ± 0.1, but this was not significantly higher than the PS only model. Conclusion: PS is the single best predictor of tumour progression when compared to other parameters, but voxel-based prediction based on logistic regression had modest sensitivity and specificity.

  5. Role of positron emission tomography-computed tomography in endometrial cancer

    Science.gov (United States)

    Erdemoğlu, Evrim; Çerçi, Sevim Süreyya; Erdemoğlu, Ebru; Yalçın, Yakup; Tatar, Burak

    2017-01-01

    Objective: The efficacy of preoperative 18F-fluoro-D-glucose (18F-FDG) positron emission tomography-computed tomography (PET-CT) in endometrium cancer is controversial. We examined the efficacy of PET-CT and the association between maximum standardized uptake value (SUVmax) and prognostic factors in endometrial cancer. Materials and Methods: Thirty patients with endometrial cancer underwent preoperative 18F-FDG/PET-CT. The patients were treated with abdominal hysterectomy with bilateral salpingo-oophorectomy, and bilateral systemic pelvic lymphadenectomy was planned for all patients; paraaortic lymphadenectomy was performed in patients with intermediate and high risk. Tumor histology, grade, depth of myometrial invasion, maximum tumor diameter, lymphovascular invasion, nodal status, and ovarian/adnexal metastases were recorded. Results: The mean primary tumor diameter was reported smaller in PET-CT and the effect size of PET-CT was -0.60. The kappa value was 0.06 for myometrial invasion. Pelvic lymph node metastasis was reported in 22.2% of patients in PET-CT. However, 3.7% of patients had pelvic lymph node metastasis. The kappa value for pelvic lymph node metastasis was 0.23, and sensitivity, specificity, and positive and negative predictive values were 100%, 80.7%, 16.6%, and 100%, respectively. Paraaortic lymph node metastasis in PET-CT was suspected in 10%. However, paraaortic lymph node metastasis was found in 6.7% in histopathologic analyses. The kappa value was 0.15. The sensitivity, specificity, and positive and negative predictive values of PET-CT for detecting paraaortic lymph node metastases were 100%, 93.7%, 66.6%, and 100%, respectively. Myometrial invasion and tumor diameter were the only important prognostic factors affecting SUVmax. Conclusion: According to our results, PET-CT has a limited role and diagnostic efficacy in endometrial cancer. The indications of FDG/PET-CT in endometrium cancer should be studied further and revised. PMID:29379661

  6. Positron emission tomography combined with computed tomography for diagnosis of synchronous and metachronous tumors

    International Nuclear Information System (INIS)

    Zlatareva, D.; Garcheva, M.; Hadjiiska, V.

    2013-01-01

    Full text: Introduction: Positron emission tomography combined computed tomography (PET/CT) has proved to be the method of choice in oncology for diagnosis and staging, planning and determining the effect of treatment. Aim of the study was to determine the diagnostic capabilities of PET/CT for the detection of synchronous and metachronous tumors. Materials and Methods: The study was conducted with 18F FDG on Discovery, GE Healthcare under standard protocol. 18F FDG is dosed per kg body weight applying before a meal in blood sugar within reference values. The survey was conducted 60 min after application, in addition to visual assessment using quantitative indicators. For a period of a year (2012) 1408 patients were studied. In 11 (2 men, 9 women) of them synchronous and metachronous unsuspected tumors were found. Results: The most common as the second tumors are found processes in the head and neck, followed by lung cancer and colorectal cancer. In four of the cases operational or histological verification was made. In others cases due to refusal or advanced disease indications for systemic therapy the verification wasn't made. Diagnosis of the second tumor has changed the approach to patients as the therapeutic effect was detected at 3 patients over a period of nine months by repeated PET/CT study. Conclusion: The hybrid PET/CT, combining information about structural changes (CT) and metabolic changes (PET) plays an important role in the diagnosis of synchronous and metachronous tumors. This can significantly change the therapeutic management and prognosis of patients

  7. Positron emission tomography/computed tomography--imaging protocols, artifacts, and pitfalls.

    Science.gov (United States)

    Bockisch, Andreas; Beyer, Thomas; Antoch, Gerald; Freudenberg, Lutz S; Kühl, Hilmar; Debatin, Jörg F; Müller, Stefan P

    2004-01-01

    There has been a longstanding interest in fused images of anatomical information, such as that provided by computed tomography (CT) or magnetic resonance imaging (MRI) systems, with biological information obtainable by positron emission tomography (PET). The near-simultaneous data acquisition in a fixed combination of a PET and a CT scanner in a combined PET/CT imaging system minimizes spatial and temporal mismatches between the modalities by eliminating the need to move the patient in between exams. In addition, using the fast CT scan for PET attenuation correction, the duration of the examination is significantly reduced compared to standalone PET imaging with standard rod-transmission sources. The main source of artifacts arises from the use of the CT-data for scatter and attenuation correction of the PET images. Today, CT reconstruction algorithms cannot account for the presence of metal implants, such as dental fillings or prostheses, properly, thus resulting in streak artifacts, which are propagated into the PET image by the attenuation correction. The transformation of attenuation coefficients at X-ray energies to those at 511 keV works well for soft tissues, bone, and air, but again is insufficient for dense CT contrast agents, such as iodine or barium. Finally, mismatches, for example, due to uncoordinated respiration result in incorrect attenuation-corrected PET images. These artifacts, however, can be minimized or avoided prospectively by careful acquisition protocol considerations. In doubt, the uncorrected images almost always allow discrimination between true and artificial finding. PET/CT has to be integrated into the diagnostic workflow for harvesting the full potential of the new modality. In particular, the diagnostic power of both, the CT and the PET within the combination must not be underestimated. By combining multiple diagnostic studies within a single examination, significant logistic advantages can be expected if the combined PET

  8. Relationship of computed tomography perfusion and positron emission tomography to tumour progression in malignant glioma

    International Nuclear Information System (INIS)

    Yeung, Timothy P C; Yartsev, Slav; Lee, Ting-Yim; Wong, Eugene; He, Wenqing; Fisher, Barbara; VanderSpek, Lauren L; Macdonald, David; Bauman, Glenn

    2014-01-01

    Introduction: This study aimed to explore the potential for computed tomography (CT) perfusion and 18-Fluorodeoxyglucose positron emission tomography (FDG-PET) in predicting sites of future progressive tumour on a voxel-by-voxel basis after radiotherapy and chemotherapy. Methods: Ten patients underwent pre-radiotherapy magnetic resonance (MR), FDG-PET and CT perfusion near the end of radiotherapy and repeated post-radiotherapy follow-up MR scans. The relationships between these images and tumour progression were assessed using logistic regression. Cross-validation with receiver operating characteristic (ROC) analysis was used to assess the value of these images in predicting sites of tumour progression. Results: Pre-radiotherapy MR-defined gross tumour; near-end-of-radiotherapy CT-defined enhancing lesion; CT perfusion blood flow (BF), blood volume (BV) and permeability-surface area (PS) product; FDG-PET standard uptake value (SUV); and SUV:BF showed significant associations with tumour progression on follow-up MR imaging (P < 0.0001). The mean sensitivity (±standard deviation), specificity and area under the ROC curve (AUC) of PS were 0.64 ± 0.15, 0.74 ± 0.07 and 0.72 ± 0.12 respectively. This mean AUC was higher than that of the pre-radiotherapy MR-defined gross tumour and near-end-of-radiotherapy CT-defined enhancing lesion (both AUCs = 0.6 ± 0.1, P ≤ 0.03). The multivariate model using BF, BV, PS and SUV had a mean AUC of 0.8 ± 0.1, but this was not significantly higher than the PS only model. Conclusion: PS is the single best predictor of tumour progression when compared to other parameters, but voxel-based prediction based on logistic regression had modest sensitivity and specificity

  9. Enhancement of positron emission tomography-computed tomography image quality using the principle of stochastic resonance

    International Nuclear Information System (INIS)

    Pandey, Anil Kumar; Sharma, Sanjay Kumar; Sharma, Punit; Singh, Harmandeep; Patel, Chetan; Sarkar, Kaushik; Kumar, Rakesh; Bal, Chandra Sekhar

    2014-01-01

    Acquisition of higher counts improves visual perception of positron emission tomography-computed tomography (PET-CT) image. Larger radiopharmaceutical doses (implies more radiation dose) are administered to acquire this count in a short time period. However, diagnostic information does not increase after a certain threshold of counts. This study was conducted to develop a post processing method based on principle of “stochastic resonance” to improve visual perception of the PET-CT image having a required threshold counts. PET-CT images (JPEG file format) with low, medium, and high counts in the image were included in this study. The image was corrupted with the addition of Poisson noise. The amplitude of the Poisson noise was adjusted by dividing each pixel by a constant 1, 2, 4, 8, 16, and 32. The best amplitude of the noise that gave best images quality was selected based on high value of entropy of the output image, high value of structural similarity index and feature similarity index. Visual perception of the image was evaluated by two nuclear medicine physicians. The variation in structural and feature similarity of the image was not appreciable visually, but statistically images deteriorated as the noise amplitude increases although maintaining structural (above 70%) and feature (above 80%) similarity of input images in all cases. We obtained the best image quality at noise amplitude “4” in which 88% structural and 95% feature similarity of the input images was retained. This method of stochastic resonance can be used to improve the visual perception of the PET-CT image. This can indirectly lead to reduction of radiation dose

  10. Quantification in emission tomography

    International Nuclear Information System (INIS)

    Buvat, Irene

    2011-11-01

    The objective of this lecture is to understand the possibilities and limitations of the quantitative analysis of single photon emission computed tomography (SPECT) and positron emission tomography (PET) images. It is also to identify the conditions to be fulfilled to obtain reliable quantitative measurements from images. Content: 1 - Introduction: Quantification in emission tomography - definition and challenges; quantification biasing phenomena 2 - Main problems impacting quantification in PET and SPECT: problems, consequences, correction methods, results (Attenuation, scattering, partial volume effect, movement, un-stationary spatial resolution in SPECT, fortuitous coincidences in PET, standardisation in PET); 3 - Synthesis: accessible efficiency, know-how, Precautions, beyond the activity measurement

  11. Simulation Study of Single Photon Emission Computed Tomography for Industrial Applications

    International Nuclear Information System (INIS)

    Roy, Tushar; Sarkar, P. S.; Sinha, Amar

    2008-01-01

    SPECT (Single Photon Emission Computed Tomography) provides for an invaluable non-invasive technique for the characterization and activity distribution of the gamma-emitting source. For many applications of radioisotopes for medical and industrial application, not only the positional information of the distribution of radioisotopes is needed but also its strength. The well-established X-ray radiography or transmission tomography techniques do not yield sufficient quantitative information about these objects. Emission tomography is one of the important methods for such characterization. Application of parallel beam, fan beam and 3D cone beam emission tomography methods have been discussed in this paper. Simulation studies to test these algorithms have been carried out to validate the technique.

  12. Fluorodeoxyglucose positron emission tomography/computed tomography findings in a patient with cerebellar mutism after operation in posterior fossa

    Directory of Open Access Journals (Sweden)

    Gonca Kara Gedik

    2017-03-01

    Full Text Available Cerebellar mutism is a transient period of speechlessness that evolves after posterior fossa surgery in children. Although direct cerebellar and brain stem injury and supratentorial dysfunction have been implicated in the mediation of mutism, the pathophysiological mechanisms involved in the evolution of this kind of mutism remain unclear. Magnetic resonance imaging revealed dentatothalamocortical tract injuries and single photon emission computed tomography showed cerebellar and cerebral hypoperfusion in patients with cerebellar mutism. However, findings with 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT in this group of patients have not been documented previously. In this clinical case, we report a patient who experienced cerebellar mutism after undergoing a posterior fossa surgery. Right cerebellar and left frontal lobe hypometabolism was shown using FDG PET/CT. The FDG metabolism of both the cerebellum and the frontal lobe returned to normal levels after the resolution of the mutism symptoms.

  13. The diagnostic value of single-photon emission computed tomography/computed tomography for severe sacroiliac joint dysfunction.

    Science.gov (United States)

    Tofuku, Katsuhiro; Koga, Hiroaki; Komiya, Setsuro

    2015-04-01

    We aimed to evaluate the value of single-photon emission computed tomography (SPECT)/computed tomography (CT) for the diagnosis of sacroiliac joint (SIJ) dysfunction. SPECT/CT was performed in 32 patients with severe SIJ dysfunction, who did not respond to 1-year conservative treatment and had a score of >4 points on a 10-cm visual analog scale. We investigated the relationship between the presence of severe SIJ dysfunction and tracer accumulation, as confirmed by SPECT/CT. In cases of bilateral SIJ dysfunction, we also compared the intensity of tracer accumulation on each side. Moreover, we examined the relationship between the intensity of tracer accumulation and the different treatments the patients subsequently received. All 32 patients with severe SIJ dysfunction had tracer accumulation with a standardized uptake value (SUV) of >2.2 (mean SUV 4.7). In the 19 patients with lateralized symptom intensity, mean SUVs of the dominant side were significantly higher than those of the nondominant side. In 10 patients with no lateralization, the difference in the SUVs between sides was dysfunction as well as a useful technique for predicting the prognosis of this condition.

  14. Contrast-enhanced fluorodeoxyglucose positron emission tomography/contrast-enhanced computed tomography in mediastinal T-cell lymphoma with superior vena cava syndrome

    International Nuclear Information System (INIS)

    Santhosh, Sampath; Gorla, Arun Kumar Reddy; Bhattacharya, Anish; Varma, Subhash Chander; Mittal, Bhagwant Rai

    2016-01-01

    Positron emission tomography-computed tomography (PET/CT) is a routine investigation for the staging of lymphomas. Contrast-enhanced computed tomography is mandatory whenever parenchymal lesions, especially in the liver and spleen are suspected. We report a rare case of primary mediastinal T-cell lymphoma evaluated with contrast-enhanced PET/CT that showed features of superior vena cava syndrome

  15. Use of computed tomography and positron emission tomography/computed tomography for staging of local extent in patients with malignant pleural mesothelioma.

    Science.gov (United States)

    Frauenfelder, Thomas; Kestenholz, Peter; Hunziker, Roger; Nguyen, Thi Dan Linh; Fries, Martina; Veit-Haibach, Patrick; Husmann, Lars; Stahel, Rolf; Weder, Walter; Opitz, Isabelle

    2015-01-01

    The objective of this study was to determine the diagnostic value of computed tomography (CT) and positron emission tomography (PET)/CT for staging of malignant pleural mesothelioma (MPM) in patients undergoing induction chemotherapy. Sixty-two patients (median age, 61 years; female: n = 9) with proven MPM underwent CT after induction chemotherapy. Of these, 28 underwent additional PET/CT. Extrapleural pneumonectomy was performed for pathological TNM staging. Clinical TNM stage was assessed by 3 independent readers. Relative and absolute underestimation and overestimation were compared with pathological tumor stage. Sensitivity, specificity, and accuracy for differentiation between stages T2 and T3 were assessed. Interobserver agreement between the readers was analyzed (κ). Positron emission tomography/CT and CT underestimated T stage in up to 30% of the cases. Positron emission tomography/CT had a higher accuracy for tumor extent compared with CT (PET/CT: 0.92; CT: 0.84). The accuracy for nodal staging was higher for CT than for PET/CT (PET/CT: 0.78; CT: 0.87). Concerning International Mesothelioma Interest Group classification, PET/CT improved the accuracy of preoperative staging compared with CT (PET/CT: 0.91; CT: 0.82). Interobserver agreement was moderate for CT (0.48-0.62) and good for PET/CT (0.64-0.83) for T staging. For nodal staging, interobserver agreement was fair to moderate for CT and good for PET/CT (CT: 0.37-0.51; PET/CT: 0.73-0.76). Positron emission tomography/CT is more accurate and has a lower interobserver variability for clinical intrathoracic staging of MPM compared with CT. Nevertheless PET/CT underestimated tumor stage in a substantial number of cases, showing the need for a more accurate imaging technology or approach.

  16. Combined computed tomography and fluorodeoxyglucose positron emission tomography in the diagnosis of prosthetic valve endocarditis: a case series.

    Science.gov (United States)

    Bartoletti, Michele; Tumietto, Fabio; Fasulo, Giovanni; Giannella, Maddalena; Cristini, Francesco; Bonfiglioli, Rachele; Raumer, Luigi; Nanni, Cristina; Sanfilippo, Silvia; Di Eusanio, Marco; Scotton, Pier Giorgio; Graziosi, Maddalena; Rapezzi, Claudio; Fanti, Stefano; Viale, Pierluigi

    2014-01-13

    The diagnosis of prosthetic valve endocarditis is challenging. The gold standard for prosthetic valve endocarditis diagnosis is trans-esophageal echocardiography. However, trans-esophageal echocardiography may result in negative findings or yield images difficult to differentiate from thrombus in patients with prosthetic valve endocarditis. Combined computed tomography and fluorodeoxyglucose positron emission tomography is a potentially promising diagnostic tool for several infectious conditions and it has also been employed in patients with prosthetic valve endocarditis but data are still scant. We reviewed the charts of 6 patients with prosthetic aortic valves evaluated for suspicion of prosthetic valve endocarditis, at two different hospital, over a 3-year period. We found 3 patients with early-onset PVE cases and blood cultures yielding Pseudomonas aeruginosa, Staphylococcus epidermidis and Staphylococcus lugdunensis, respectively; and 3 late-onset cases in the remaining 3 patients with isolation in the blood of Streptococcus bovis, Candida albicans and P. aeruginosa, respectively. Initial trans-esophageal echocardiography was negative in all the patients, while fluorodeoxyglucose positron emission tomography showed images suspicious for prosthetic valve endocarditis. In 4 out of 6 patients valve replacement was done with histology confirming the prosthetic valve endocarditis diagnosis. After an adequate course of antibiotic therapy fluorodeoxyglucose positron emission tomography showed resolution of prosthetic valve endocarditis in all the patients. Our experience confirms the potential role of fluoroseoxyglucose positron emission tomography in the diagnosis and follow-up of prosthetic valve endocarditis.

  17. Single photon emission computed tomography in lumbar degenerative spondylolisthesis

    International Nuclear Information System (INIS)

    Ito, S.; Muro, T.; Eisenstein, S.

    1998-01-01

    Analysis of single photon emission computed tomographic images and plain X-ray films of the lumbar vertebrae was performed in 15 patients with lumbar spondylosis and 15 patients with lumbar degenerative spondylolisthesis. The facet joint and osteophyte images were observed in particular, and the slipping ratio of spondylolisthetic vertebrae was determined. The slipping ratio of degenerative spondylolisthesis ranged from 11.8 % to 22.3 %. Hot uptake of 99mTc-HMDP by both L4-5 facet joints was significantly greater in the patients with degenerative spondylolisthesis than in those with lumbar spondylosis. The hot uptake by the osteophytes in lumbar spondylosis was nearly uniform among the three inferior segments, L3-4, L4-5 and L5-S, but was localized to the spondylolisthetic vertebrae, L4-5, or L5-S, in the patients with spondylolisthesis. Half of the osteophytes with hot uptake were assigned to the 3rd degree of Nathan's grading. It was suggested that stress was localized to the slipping vertebrae and their facet joints in patients with lumbar degenerative spondylolisthesis. (author)

  18. Positron Emission Tomography Computed Tomography: A Guide for the General Radiologist.

    Science.gov (United States)

    Beadsmoore, Clare; Newman, David; MacIver, Duncan; Pawaroo, Davina

    2015-11-01

    Cancer remains a leading cause of death in Canada and worldwide. Whilst advances in anatomical imaging to detect and monitor malignant disease have continued over the last few decades, limitations remain. Functional imaging, such as positron emission tomography (PET), has improved the sensitivity and specificity in detecting malignant disease. In combination with computed tomography (CT), PET is now commonly used in the oncology setting and is an integral part of many cancer patients' pathways. Although initially the CT component of the study was purely for attenuation of the PET imaging and to provide anatomical coregistration, many centers now combine the PET study with a diagnostic quality contrast enhanced CT to provide one stop staging, thus refining the patient's pathway. The commonest tracer used in everyday practice is FDG (F18-fluorodeoxyglucose). There are many more tracers in routine clinical practice and those with emerging roles, such as 11C-choline, useful in the imaging of prostate cancer; 11C-methionine, useful in imaging brain tumours; C11-acetate, used in imaging hepatocellular carcinomas; 18F-FLT, which can be used as a marker of cellular proliferation in various malignancies; and F18-DOPA and various 68Ga-somatostatin analogues, used in patients with neuroendocrine tumours. In this article we concentrate on FDG PETCT as this is the most commonly available and widely utilised tracer now used to routinely stage a number of cancers. PETCT alters the stage in approximately one-third of patients compared to anatomical imaging alone. Increasingly, PETCT is being used to assess early metabolic response to treatment. Metabolic response can be seen much earlier than a change in the size/volume of the disease which is measured by standard CT imaging. This can aid treatment decisions in both in terms of modifying therapy and in addition to providing important prognostic information. Furthermore, it is helpful in patients with distorted anatomy from surgery

  19. Budget impact from the incorporation of positron emission tomography - computed tomography for staging lung cancers.

    Science.gov (United States)

    Biz, Aline Navega; Caetano, Rosângela

    2015-01-01

    To estimate the budget impact from the incorporation of positron emission tomography (PET) in mediastinal and distant staging of non-small cell lung cancer. The estimates were calculated by the epidemiological method for years 2014 to 2018. Nation-wide data were used about the incidence; data on distribution of the disease's prevalence and on the technologies' accuracy were from the literature; data regarding involved costs were taken from a micro-costing study and from Brazilian Unified Health System (SUS) database. Two strategies for using PET were analyzed: the offer to all newly-diagnosed patients, and the restricted offer to the ones who had negative results in previous computed tomography (CT) exams. Univariate and extreme scenarios sensitivity analyses were conducted to evaluate the influence from sources of uncertainties in the parameters used. The incorporation of PET-CT in SUS would imply the need for additional resources of 158.1 BRL (98.2 USD) million for the restricted offer and 202.7 BRL (125.9 USD) million for the inclusive offer in five years, with a difference of 44.6 BRL (27.7 USD) million between the two offer strategies within that period. In absolute terms, the total budget impact from its incorporation in SUS, in five years, would be 555 BRL (345 USD) and 600 BRL (372.8 USD) million, respectively. The costs from the PET-CT procedure were the most influential parameter in the results. In the most optimistic scenario, the additional budget impact would be reduced to 86.9 BRL (54 USD) and 103.8 BRL (64.5 USD) million, considering PET-CT for negative CT and PET-CT for all, respectively. The incorporation of PET in the clinical staging of non-small cell lung cancer seems to be financially feasible considering the high budget of the Brazilian Ministry of Health. The potential reduction in the number of unnecessary surgeries may cause the available resources to be more efficiently allocated.

  20. Budget impact from the incorporation of positron emission tomographycomputed tomography for staging lung cancers

    Directory of Open Access Journals (Sweden)

    Aline Navega Biz

    2015-01-01

    Full Text Available OBJECTIVE To estimate the budget impact from the incorporation of positron emission tomography (PET in mediastinal and distant staging of non-small cell lung cancer.METHODS The estimates were calculated by the epidemiological method for years 2014 to 2018. Nation-wide data were used about the incidence; data on distribution of the disease´s prevalence and on the technologies’ accuracy were from the literature; data regarding involved costs were taken from a micro-costing study and from Brazilian Unified Health System (SUS database. Two strategies for using PET were analyzed: the offer to all newly-diagnosed patients, and the restricted offer to the ones who had negative results in previous computed tomography (CT exams. Univariate and extreme scenarios sensitivity analyses were conducted to evaluate the influence from sources of uncertainties in the parameters used.RESULTS The incorporation of PET-CT in SUS would imply the need for additional resources of 158.1 BRL (98.2 USD million for the restricted offer and 202.7 BRL (125.9 USD million for the inclusive offer in five years, with a difference of 44.6 BRL (27.7 USD million between the two offer strategies within that period. In absolute terms, the total budget impact from its incorporation in SUS, in five years, would be 555 BRL (345 USD and 600 BRL (372.8 USD million, respectively. The costs from the PET-CT procedure were the most influential parameter in the results. In the most optimistic scenario, the additional budget impact would be reduced to 86.9 BRL (54 USD and 103.8 BRL (64.5 USD million, considering PET-CT for negative CT and PET-CT for all, respectively.CONCLUSIONS The incorporation of PET in the clinical staging of non-small cell lung cancer seems to be financially feasible considering the high budget of the Brazilian Ministry of Health. The potential reduction in the number of unnecessary surgeries may cause the available resources to be more efficiently allocated.

  1. Does positron emission tomography/computed tomography aid the diagnosis of prosthetic valve infective endocarditis?

    Science.gov (United States)

    Balmforth, Damian; Chacko, Jacob; Uppal, Rakesh

    2016-10-01

    A best evidence topic was constructed according to a structured protocol. The question addressed was whether (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) aids the diagnosis of prosthetic valve endocarditis (PVE)? A total of 107 publications were found using the reported search, of which 6 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. The reported outcome of all studies was a final diagnosis of confirmed endocarditis on follow-up. All the six studies were non-randomized, single-centre, observational studies and thus represented level 3 evidence. The diagnostic capability of PET/CT for PVE was compared with that of the modified Duke Criteria and echocardiography, and reported in terms of sensitivity, specificity and positive and negative predictive values. All studies demonstrated an increased sensitivity for the diagnosis of PVE when PET/CT was combined with the modified Duke Criteria on admission. A higher SUVmax on PET was found to be significantly associated with a confirmed diagnosis of endocarditis and an additional diagnostic benefit of PET/CT angiography over conventional PET/non-enhanced CT is reported due to improved anatomical resolution. However, PET/CT was found to be unreliable in the early postoperative period due to its inability to distinguish between infection and residual postoperative inflammatory changes. PET/CT was also found to be poor at diagnosing cases of native valve endocarditis. We conclude that PET/CT aids in the diagnosis of PVE when combined with the modified Duke Criteria on admission by increasing the diagnostic sensitivity. The diagnostic ability of PET/CT can be potentiated by the use of PET/CTA; however, its use may be unreliable in the early postoperative period or in native valve endocarditis. © The Author 2016. Published by

  2. Sacrococcygeal chordoma: increased 99mTc methylene diphosphonate uptake on single photon emission computed tomography/computed tomography bone scintigraphy

    International Nuclear Information System (INIS)

    Kamaleshwaran, Koramadai Karuppuswamy; Bhattacharya, Anish; Harisankar, Chidambaram Natarajan Balasubramaniam; Mittal, Bhagwant Rai; Goni, Vijay

    2012-01-01

    Chordoma is a malignant tumor arising from the remnants of the notochord, and is the most frequent primitive tumor of the sacrum. While most sacral tumors show increased concentration of bone-seeking radiopharmaceuticals, chordomas usually exhibit decreased uptake. The authors present an image of a sacrococcygeal chordoma with osteolysis and increased uptake of 99m Tc methylene diphosphonate on planar and single photon emission computed tomography/computed tomography bone scintigraphy. (author)

  3. Positron emission tomography

    International Nuclear Information System (INIS)

    Wienhard, K.; Heiss, W.D.

    1984-01-01

    The principles and selected clinical applications of positron emission tomography are described. In this technique a chemical compound is labeled with a positron emitting isotope and its biochemical pathway is traced by coincidence detection of the two annihilation photons. The application of the techniques of computed tomography allows to reconstruct the spatial distribution of the radioactivity within a subject. The 18 F-deoxyglucose method for quantitative measurement of local glucose metabolism is discussed in order to illustrate the possibilities of positron emission tomography to record physiological processes in vivo. (orig.) [de

  4. Data on analysis of coronary atherosclerosis on computed tomography and 18F-sodium fluoride positron emission tomography

    Directory of Open Access Journals (Sweden)

    Toshiro Kitagawa

    2017-08-01

    Full Text Available This article contains the data showing illustrative examples of plaque classification on coronary computed tomography angiography (CCTA and measurement of 18F-sodium fluoride (18F-NaF uptake in coronary atherosclerotic lesions on positron emission tomography (PET. We divided the lesions into one of three plaque types on CCTA (calcified plaque, non-calcified plaque, partially calcified plaque. Focal 18F-NaF uptake of each lesion was quantified using maximum tissue-to-background ratio. This article also provides a representative case with a non-calcified coronary plaque detected on CCTA and identified on 18F-NaF PET/non-contrast computed tomography based on a location of a vessel branch as a landmark. These complement the data reported by Kitagawa et al. (2017 [1].

  5. Utility of Quantitative Parameters from Single-Photon Emission Computed Tomography/Computed Tomography in Patients with Destructive Thyroiditis

    Science.gov (United States)

    Kim, Ji-Young; Kim, Ji Hyun; Moon, Jae Hoon; Kim, Kyoung Min; Oh, Tae Jung; Lee, Dong-Hwa; So, Young

    2018-01-01

    Objective Quantitative parameters from Tc-99m pertechnetate single-photon emission computed tomography/computed tomography (SPECT/CT) are emerging as novel diagnostic markers for functional thyroid diseases. We intended to assess the utility of SPECT/CT parameters in patients with destructive thyroiditis. Materials and Methods Thirty-five destructive thyroiditis patients (7 males and 28 females; mean age, 47.3 ± 13.0 years) and 20 euthyroid patients (6 males and 14 females; mean age, 45.0 ± 14.8 years) who underwent Tc-99m pertechnetate quantitative SPECT/CT were retrospectively enrolled. Quantitative parameters from the SPECT/CT (%uptake, standardized uptake value [SUV], thyroid volume, and functional thyroid mass [SUVmean × thyroid volume]) and thyroid hormone levels were investigated to assess correlations and predict the prognosis for destructive thyroiditis. The occurrence of hypothyroidism was the outcome for prognosis. Results All the SPECT/CT quantitative parameters were significantly lower in the 35 destructive thyroiditis patients compared to the 20 euthyroid patients using the same SPECT/CT scanner and protocol (p thyroid-stimulating hormone (TSH) significantly correlated with %uptake (p = 0.004), SUVmean (p thyroid mass (p thyroiditis patients, 16 progressed to hypothyroidism. On univariate and multivariate analyses, only T3 levels were associated with the later occurrence of hypothyroidism (p = 0.002, exp(β) = 1.022, 95% confidence interval: 1.008 – 1.035). Conclusion Novel quantitative SPECT/CT parameters could discriminate patients with destructive thyroiditis from euthyroid patients, suggesting the robustness of the quantitative SPECT/CT approach. However, disease progression of destructive thyroiditis could not be predicted using the parameters, as these only correlated with TSH, but not with T3, the sole predictor of the later occurrence of hypothyroidism. PMID:29713225

  6. Clinical value of whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of metastatic bladder cancer.

    Science.gov (United States)

    Yang, Zhongyi; Pan, Lingling; Cheng, Jingyi; Hu, Silong; Xu, Junyan; Ye, Dingwei; Zhang, Yingjian

    2012-07-01

    To investigate the value of whole-body fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography for the detection of metastatic bladder cancer. From December 2006 to August 2010, 60 bladder cancer patients (median age 60.5 years old, range 32-96) underwent whole body positron emission tomography/computed tomography positron emission tomography/computed tomography. The diagnostic accuracy was assessed by performing both organ-based and patient-based analyses. Identified lesions were further studied by biopsy or clinically followed for at least 6 months. One hundred and thirty-four suspicious lesions were identified. Among them, 4 primary cancers (2 pancreatic cancers, 1 colonic and 1 nasopharyngeal cancer) were incidentally detected, and the patients could be treated on time. For the remaining 130 lesions, positron emission tomography/computed tomography detected 118 true positive lesions (sensitivity = 95.9%). On the patient-based analysis, the overall sensitivity and specificity resulted to be 87.1% and 89.7%, respectively. There was no difference of sensitivity and specificity in patients with or without adjuvant treatment in terms of detection of metastatic sites by positron emission tomography/computed tomography. Compared with conventional imaging modality, positron emission tomography/computed tomography correctly changed the management in 15 patients (25.0%). Positron emission tomography/computed tomography has excellent sensitivity and specificity in the detection of metastatic bladder cancer and it provides additional diagnostic information compared to standard imaging techniques. © 2012 The Japanese Urological Association.

  7. Clinical value of whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of metastatic bladder cancer

    International Nuclear Information System (INIS)

    Yang Zhongyi; Pan Lingling; Cheng Jingyi; Hu Silong; Xu Junyan; Zhang Yingjian; Ye Dingwei

    2012-01-01

    The objective of this study was to investigate the value of whole-body fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography for the detection of metastatic bladder cancer. From December 2006 to August 2010, 60 bladder cancer patients (median age 60.5 years old, range 32-96) underwent whole body positron emission tomography/computed tomography positron emission tomography/computed tomography. The diagnostic accuracy was assessed by performing both organ-based and patient-based analyses. Identified lesions were further studied by biopsy or clinically followed for at least 6 months. One hundred and thirty-four suspicious lesions were identified. Among them, 4 primary cancers (2 pancreatic cancers, 1 colonic and 1 nasopharyngeal cancer) were incidentally detected, and the patients could be treated on time. For the remaining 130 lesions, positron emission tomography/computed tomography detected 118 true positive lesions (sensitivity=95.9%). On the patient-based analysis, the overall sensitivity and specificity resulted to be 87.1% and 89.7%, respectively. There was no difference of sensitivity and specificity in patients with or without adjuvant treatment in terms of detection of metastatic sites by positron emission tomography/computed tomography. Compared with conventional imaging modality, positron emission tomography/computed tomography correctly changed the management in 15 patients (25.0%). Positron emission tomography/computed tomography has excellent sensitivity and specificity in the detection of metastatic bladder cancer and it provides additional diagnostic information compared to standard imaging techniques. (author)

  8. Recurrent proliferating trichilemmal tumor with malignant change on the f-18 fluorodeoxyglucose position emission tomography/computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Eun Ha; Kim, Eun Ha; Kim, Young Jun; Yoo, Seol Bong; Nam, Kyung Hwa [Presbyterian Medical Center, Seonam University College of Medicine, Jeonju (Korea, Republic of)

    2016-06-15

    F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography scan has been used for the diagnosis, assessment of treatment response, and follow-up of various neoplasms. Proliferating trichilemmal cyst or tumor (PTT) is a rare neoplasm, originated from the outer root sheath of a hair follicle. Because this tumor has unpredictable biological and clinical behavior, the long-term clinical follow-up is necessary to detect metastasis or recurrence. We reported a case of recurrent malignant PTT on scalp that showed increased FDG uptake.

  9. Spectrum of fluorodeoxyglucose-positron emission tomography/computed tomography and magnetic resonance imaging findings of ovarian tumors.

    Science.gov (United States)

    Kitajima, Kazuhiro; Ueno, Yoshiko; Maeda, Tetsuo; Murakami, Koji; Kaji, Yasushi; Kita, Masato; Suzuki, Kayo; Sugimura, Kazuro

    2011-11-01

    The purpose of this article is to review fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) and magnetic resonance imaging (MRI) findings in a variety of benign, malignant, and borderline malignant ovarian tumors. It is advantageous to become familiar with the wide variety of FDG-PET/CT findings of this entity. Benign ovarian tumors generally have faint uptake, whereas endometriomas, fibromas, and teratomas show mild to moderate uptake. Malignant ovarian tumors generally have intense uptake, whereas tumors with a small solid component often show minimal uptake.

  10. Positron emission tomography/computed tomography and biomarkers for early treatment response evaluation in metastatic colon cancer

    DEFF Research Database (Denmark)

    Engelmann, Bodil E.; Loft, Annika; Kjær, Andreas

    2014-01-01

    BACKGROUND: Treatment options for metastatic colon cancer (mCC) are widening. We prospectively evaluated serial 2-deoxy-2-[18F]fluoro-d-glucose positron-emission tomography/computed tomography (PET/CT) and measurements of tissue inhibitor of metalloproteinases-1 (TIMP-1), carcinoembryonic antigen...... evaluated by PET/CT before treatment, after one and four treatment series. Morphological and metabolic response was independently assessed according to Response Evaluation Criteria in Solid Tumors and European Organization for Research and Treatment of Cancer PET criteria. Plasma TIMP-1, plasma u...

  11. Contrast-enhanced 18F-fluorodeoxyglucose positron emission tomography/computed tomography in immunoglobulin G4-related retroperitoneal fibrosis

    International Nuclear Information System (INIS)

    Sharma, Punit; Chatterjee, Piyali

    2015-01-01

    Immunoglobulin G4 (IgG4)-related disease encompasses a wide variety of immune disorders previously thought be distinct. IgG4-related retroperitoneal fibrosis is one such entity. Metabolic imaging with 18 F-fluorodeoxyglucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) can be useful in the management of IgG4-related retroperitoneal fibrosis. We here discuss the case of 63-year-old male with IgG4-related retroperitoneal fibrosis and the role, 18 F-FDG PET/CT played in his management

  12. Budget impact from the incorporation of positron emission tomography ? computed tomography for staging lung cancers

    OpenAIRE

    Biz, Aline Navega; Caetano, Ros?ngela

    2015-01-01

    OBJECTIVE To estimate the budget impact from the incorporation of positron emission tomography (PET) in mediastinal and distant staging of non-small cell lung cancer.METHODS The estimates were calculated by the epidemiological method for years 2014 to 2018. Nation-wide data were used about the incidence; data on distribution of the disease´s prevalence and on the technologies’ accuracy were from the literature; data regarding involved costs were taken from a micro-costing study and from Brazi...

  13. [Treatment choice in dacryostenosis based on single-photon emission computed tomography and X-ray computed tomography findings].

    Science.gov (United States)

    At'kova, E L; Yartsev, V D; Tomashevskiy, I O; Krakhovetskiy, N N

    2016-01-01

    To develop surgical indications in dacryostenosis within the vertical portion of lacrimal pathways that would consider findings of single-photon emission computed tomography (SPECT) combined with X-ray computed tomography (CT). A total of 96 patients with isolated vertical-portion dacryostenosis (127 cases) were enrolled. The examination included collecting Munk's scores for epiphora, optical coherence tomography of the lower tear meniscus, lacrimal scintigraphy, and SPECT/CT. Group 1 (40 cases) was composed of patients with lacrimal obstruction on CT, group 2 (87 cases) - of those whose lacrimal pathways proved passable. There were also 3 patients (4 cases) from group 1, whose lacrimal pathways, despite being blocked on CT, were still passable on SPECT. Surgeries performed in group 1 were endoscopic endonasal dacryocystorhinostomy (DCR) (36 cases) and pathways recanalization with bicanalicular intubation and balloon dacryoplasty (DCP) (4 cases). In group 2, all patients (87 cases) underwent recanalization with bicanalicular intubation (supplemented with balloon DCP in 32 cases). Surgical results were evaluated 8-12 months after the treatment. In group 2, particular attention was paid to the concordance in locations of dacryostenosis provided by CT and SPECT scans. Favorable outcomes of endoscopic endonasal DCR were obtained in as many as 32 cases from group 1 (88.9%), while in 4 cases (12.1%) the condition relapsed. Of those patients whose stenosis was not complete on SPECT, 3 cases (75.0%) improved, 1 (25.0%) - relapsed. In group 2, favorable outcomes were obtained in 65 cases (74.7%), relapses were 22 (25.3%). A high concordance in stenosis locations by CT and SPECT was noted in 60 cases of those who improved (92.3%) and 3 cases of those who relapsed (13.6%). The value of information provided by SPECT/CT has proved high in patients with nasolacrimal duct stenosis or obstruction. A combined scan allows to establish causal relationships between anatomical changes

  14. Comparison of single photon emission computed tomography-computed tomography, computed tomography, single photon emission computed tomography and planar scintigraphy for characterization of isolated skull lesions seen on bone scintigraphy in cancer patients

    International Nuclear Information System (INIS)

    Sharma, Punit; Jain, Tarun Kumar; Reddy, Rama Mohan; Faizi, Nauroze Ashgar; Bal, Chandrasekhar; Malhotra, Arun; Kumar, Rakesh

    2014-01-01

    The purpose of this study is to evaluate the added value of single photon emission computed tomography-computed tomography (SPECT-CT) over planar scintigraphy, SPECT and CT alone for characterization of isolated skull lesions in bone scintigraphy (BS) in cancer patients. A total of 32 cancer patients (age: 39.5 ± 21.9; male: female - 1:1) with 36 isolated skull lesions on planar BS, underwent SPECT-CT of skull. Planar BS, SPECT, CT and SPECT-CT images were evaluated in separate sessions to minimize recall bias. A scoring scale of 1-5 was used, where 1 is definitely metastatic, 2 is probably metastatic, 3 is indeterminate, 4 is probably benign and 5 is definitely benign. With receiver operating characteristic analysis area under the curves (AUC) was calculated for each modality. For calculation of sensitivity, specificity and predictive values a Score ≤3 was taken as metastatic. Clinical/imaging follow-up and/or histopathology were taken as reference standard. Of 36 skull lesions 11 lesions each were on frontal, parietal and occipital bone while three lesions were in the temporal bone. Of these 36 lesions, 16 were indeterminate (Score-3) on planar and SPECT, five on CT and none on SPECT-CT. The AUC was largest for SPECT-CT followed by CT, SPECT and planar scintigraphy, respectively. Planar scintigraphy was inferior to SPECT-CT (P = 0.006) and CT (P = 0.012) but not SPECT (P = 0.975). SPECT was also inferior to SPECT-CT (P = 0.007) and CT (P = 0.015). Although no significant difference was found between SPECT-CT and CT (P = 0.469), the former was more specific (100% vs. 94%). SPECT-CT is better than planar scintigraphy and SPECT alone for correctly characterizing isolated skull lesions on BS in cancer patients. It is more specific than CT, but provides no significant advantage over CT alone for this purpose

  15. Lung Cancer in Patients With Tuberculous Fibrothorax and Empyema: Computed Tomography and 18F-Fluorodeoxyglucose Positron Emission Tomography Findings.

    Science.gov (United States)

    Xu, Hai; Koo, Hyun Jung; Lee, Han Na; Lim, Soyeoun; Lee, Jae Wook; Choi, Chang-Min; Kim, Mi Young

    The aim of this study was to describe the characteristics of lung cancers in patients with tuberculous fibrothorax or empyema. We retrospectively evaluated 138 consecutive patients with a diagnosis of lung cancer combined with fibrothorax (n = 127) or empyema (n = 11) from January 2005 to May 2015. All patients underwent computed tomography, and 105 underwent F-fluorodeoxyglucose positron emission tomography. Clinical, pathologic, and computed tomography characteristics and maximum standardized uptake values on positron emission tomography of 76 cancers ipsilateral to the fibrothorax or empyema (group 1) were compared with those of 62 contralateral cancers (group 2). The median age at diagnosis of patients was 70 years, with a male-to-female ratio of 8.9:1. The most common type was squamous cell carcinoma (41.3%) followed by adenocarcinoma (39.1%). Most were in the peripheral lung (70.3%), and half abutted the pleura. The median maximum standardized uptake value was 8.9. Tumors in group 1 were larger (median, 48.5 vs 42.8 mm, P = 0.036) and more advanced (T3 or T4) (P = 0.014) than those in group 2. Lung cancers ipsilateral to tuberculous fibrothorax or empyema presented larger and advanced T stages, and the diagnosis could be delayed. The most common type cancer was squamous cell carcinoma.

  16. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using (18) F-fluorodeoxyglucose positron emission tomography-computed tomography.

    Science.gov (United States)

    Kimizuka, Yoshifumi; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko; Hasegawa, Naoki

    2013-11-14

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess.

  17. A case of skeletal tuberculosis and psoas abscess: disease activity evaluated using 18 F-fluorodeoxyglucose positron emission tomography-computed tomography

    International Nuclear Information System (INIS)

    Kimizuka, Yoshifumi; Hasegawa, Naoki; Ishii, Makoto; Murakami, Koji; Ishioka, Kota; Yagi, Kazuma; Ishii, Ken; Watanabe, Kota; Soejima, Kenzo; Betsuyaku, Tomoko

    2013-01-01

    Psoas abscess complicating tuberculous spondylitis is a rare morbidity in extrapulmonary tuberculosis. There are no established guidelines for evaluating the clinical response of psoas abscess. Although several studies have shown that positron emission tomography-computed tomography with 18 F-fluorodeoxyglucose can play a potential role in diagnosing multifocal tuberculosis and monitoring the clinical response of pulmonary tuberculosis, to our knowledge, this is the first report demonstrating that positron emission tomography-computed tomography is useful for evaluating local inflammation and disease activity of a tuberculous psoas abscess. We report a case of multifocal bone and lymph node tuberculosis with concomitant lumbar psoas abscess in a 77-year-old man, along with a literature review. An initial positron emission tomography-computed tomography scan showed intense 18 F-fluorodeoxyglucose accumulation in the sternum, ribs, vertebrae, and lymph nodes. The patient was successfully treated with antitubercular agents and computed tomography-guided drainage therapy. A follow-up positron emission tomography-computed tomography after abscess drainage and 9 months of antitubercular drug treatment revealed that the majority of lesions improved; however, protracted inflammation surrounding the psoas abscess was still observed. These results indicate that disease activity of psoas abscess can remain, even after successful drainage and antitubercular medication regime of appropriate duration. We have successfully followed up the extent of skeletal tuberculosis complicated with psoas abscess by positron emission tomography-computed tomography. In this patient, positron emission tomography-computed tomography is useful for evaluating the disease activity of tuberculous psoas abscess and for assessing the appropriate duration of antitubercular drug therapy in psoas abscess

  18. Utility of single photon emission computed tomography/computed tomography imaging in evaluation of chronic low back pain

    International Nuclear Information System (INIS)

    Harisankar, Chidambaram Natrajan Balasubramanian; Mittal, Bhagwant Rai; Bhattacharya, Anish; Singh, Paramjeet; Sen, Ramesh

    2012-01-01

    Abnormal morphologic findings in imaging were thought to explain the etiology of low back pain (LBP). However, it is now known that variety of morphologic abnormalities is noted even in asymptomatic individuals. Single photon emission computed tomography/computed tomography (SPECT/CT) could be used to differentiate incidental findings from clinically significant findings. This study was performed to define the SPECT/CT patterns in patients with LBP and to correlate these with clinical and magnetic resonance imaging (MRI) findings. Thirty adult patients with LBP of duration 3 months or more were prospectively evaluated in this study. Patients with known or suspected malignancy, trauma or infectious processes were excluded. A detailed history of sensory and motor symptoms and neurologic examination was performed. All the patients were subjected to MRI and bone scintigraphy with hybrid SPECT/CT of the lumbo-sacral spine within 1 month of each other. The patients were classified into those with and without neurologic symptoms, activity limitation. The findings of clinical examination and imaging were compared. MRI and SPECT/CT findings were also compared. Thirty patients (18 men and 12 women; mean age 38 years; range 17-64 years) were eligible for the study. Clinically, 14 of 30 (46%) had neurologic signs and or symptoms. Six of the 30 patients (20%) had positive straight leg raising test (SLRT). Twenty-two of the 30 patients (73%) had SPECT abnormality. Most frequent SPECT/CT abnormality was tracer uptake in the anterior part of vertebral body with osteophytes/sclerotic changes. Significant positive agreement was noted between this finding and MRI evidence of degenerative disc disease. Only 13% of patients had more than one abnormality in SPECT. All 30 patients had MRI abnormalities. The most frequent abnormality was degenerative disc disease and facet joint arthropathy. MRI showed single intervertebral disc abnormality in 36% of the patients and more than one

  19. PET and Single-Photon Emission Computed Tomography in Brain Concussion.

    Science.gov (United States)

    Raji, Cyrus A; Henderson, Theodore A

    2018-02-01

    This article offers an overview of the application of PET and single photon emission computed tomography brain imaging to concussion, a type of mild traumatic brain injury and traumatic brain injury, in general. The article reviews the application of these neuronuclear imaging modalities in cross-sectional and longitudinal studies. Additionally, this article frames the current literature with an overview of the basic physics and radiation exposure risks of each modality. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Degenerative dementia: nosological aspects and results of single photon emission computed tomography

    International Nuclear Information System (INIS)

    Dubois, B.; Habert, M.O.

    1999-01-01

    Ten years ago, the diagnosis discussion of a dementia case for the old patient was limited to two pathologies: the Alzheimer illness and the Pick illness. During these last years, the frame of these primary degenerative dementia has fallen into pieces. The different diseases and the results got with single photon emission computed tomography are discussed. for example: fronto-temporal dementia, primary progressive aphasia, progressive apraxia, visio-spatial dysfunction, dementia at Lewy's bodies, or cortico-basal degeneration. (N.C.)

  1. Noninvasive measurement of regional myocardial glucose metabolism by positron emission computed tomography

    International Nuclear Information System (INIS)

    Schelbert, H.R.; Phelps, M.E.

    While the results of regional myocardial glucose metabolism measurements using positron emission computed tomography ( 13 N-ammonia) are promising, their utility and value remains to be determined in man. If this technique can be applied to patients with acute myocardial ischemia or infarction it may permit delineation of regional myocardial segments with altered, yet still active metabolism. Further, it may become possible to evaluate the effects of interventions designed to salvage reversibly injured myocardium by this technique

  2. Imaging by single photon emission computed tomography: interest in the pre surgical check up of epilepsy

    International Nuclear Information System (INIS)

    Biraben, A.; Bernard, A.M.

    1999-01-01

    With the single photon emission computed tomography, it is a more reliable technique that is at someone's disposal, especially to limit spatially the evolution of epilepsy crisis before any surgery act. The determination of the precise area is necessary to make sure that the crisis come really from this area and the determination of the functionality of this area is checked to be sure that the ablation of the zone will not lead to an unacceptable functional deficit. (N.C.)

  3. Single photon emission computed tomography by using fan beam collimator

    International Nuclear Information System (INIS)

    Akiyama, Yoshihisa

    1992-01-01

    A multislice fan beam collimator which has parallel collimation along the cephalic-caudul axis of a patient and converging collimation within planes that are perpendicular to that axis was designed for a SPECT system with a rotating scintillation camera, and it was constructed by the lead casting method which was developed in recent years. A reconstruction algorithm for fan beam SPECT was formed originally by combining the reconstruction algorithm of the parallel beam SPECT with that of the fan beam X-ray CT. The algorithm for fan beam SPECT was confirmed by means of computer simulation and a head phantom filled with diluted radionuclide. Not only 99m Tc but also 123 I was used as a radionuclide. A SPECT image with the fan beam collimator was compared with that of a parallel hole, low energy, high resolution collimator which was routinely used for clinical and research SPECT studies. Both system resolution and sensitivity of the fan beam collimator were ∼20% better than those of the parallel hole collimator. Comparing SPECT images obtained from fan beam collimator with those of parallel hole collimator, the SPECT images using fan beam collimator had far better resolution. A fan beam collimator is a useful implement for the SPECT study. (author)

  4. Myocardial blood flow quantification for evaluation of coronary artery disease by positron emission tomography, cardiac magnetic resonance imaging, and computed tomography.

    Science.gov (United States)

    Waller, Alfonso H; Blankstein, Ron; Kwong, Raymond Y; Di Carli, Marcelo F

    2014-05-01

    The noninvasive detection of the presence and functional significance of coronary artery stenosis is important in the diagnosis, risk assessment, and management of patients with known or suspected coronary artery disease. Quantitative assessment of myocardial perfusion can provide an objective and reproducible estimate of myocardial ischemia and risk prediction. Positron emission tomography, cardiac magnetic resonance, and cardiac computed tomography perfusion are modalities capable of measuring myocardial blood flow and coronary flow reserve. In this review, we will discuss the technical aspects of quantitative myocardial perfusion imaging with positron emission tomography, cardiac magnetic resonance imaging, and computed tomography, and its emerging clinical applications.

  5. Role of single photon emission computed tomography/computed tomography in diagnostic iodine-131 scintigraphy before initial radioiodine ablation in differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Agrawal, Kanhaiyalal; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2005-01-01

    The study was performed to evaluate the incremental value of single photon emission computed tomography/computed tomography (SPECT/CT) over planar radioiodine imaging before radioiodine ablation in the staging, management and stratification of risk of recurrence (ROR) in differentiated thyroid cancer (DTC) patients. Totally, 83 patients (21 male, 62 female) aged 17–75 (mean 39.9) years with DTC were included consecutively in this prospective study. They underwent postthyroidectomy planar and SPECT/CT scans after oral administration of 37–114 MBq iodine-131 (I-131). The scans were interpreted as positive, negative or suspicious for tracer uptake in the thyroid bed, cervical lymph nodes and sites outside the neck. In each case, the findings on planar images were recorded first, without knowledge of SPECT/CT findings. Operative and pathological findings were used for postsurgical tumor–node–metastasis staging. The tumor staging was reassessed after each of these two scans. Single photon emission computed tomography/computed tomography localized radioiodine uptake in the thyroid bed in 9/83 (10.8%) patients, neck nodes in 24/83 (28.9%) patients and distant metastases in 8/83 (9.6%) patients in addition to the planar study. Staging was changed in 8/83 (9.6%), ROR in 11/83 (13.2%) and management in 26/83 (31.3%) patients by the pretherapy SPECT/CT in comparison to planar imaging. SPECT/CT had incremental value in 32/83 patients (38.5%) over the planar scan. Single photon emission computed tomography/computed tomography is feasible during a diagnostic I-131 scan with a low amount of radiotracer. It improved the interpretation of pretherapy I-131 scintigraphy and changed the staging and subsequent patient management

  6. Computed tomography

    International Nuclear Information System (INIS)

    Andre, M.; Resnick, D.

    1988-01-01

    Computed tomography (CT) has matured into a reliable and prominent tool for study of the muscoloskeletal system. When it was introduced in 1973, it was unique in many ways and posed a challenge to interpretation. It is in these unique features, however, that its advantages lie in comparison with conventional techniques. These advantages will be described in a spectrum of important applications in orthopedics and rheumatology

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  8. Illustrated computer tomography

    International Nuclear Information System (INIS)

    Takahashi, S.

    1983-01-01

    This book provides the following information: basic aspects of computed tomography; atlas of computed tomography of the normal adult; clinical application of computed tomography; and radiotherapy planning and computed tomography

  9. Single-photon emission computed tomography in the clinical evaluation of dementia

    International Nuclear Information System (INIS)

    Jagust, W.J.; Reed, B.R.; Budinger, T.F.; Colina, M.

    1987-01-01

    Physiological imaging using positron emission tomography (PET) has been a useful tool in the investigation of dementia. In particular, patterns of cerebral glucose utilization appear to differentiate various types of dementia, with Alzheimer's disease (AD) demonstrating a propensity for hypometabolism to involve the temporoparietal cortex. Single-photon emission computed tomography (SPECT) using new tracers for the measurement of regional cerebral blood flow is a technique with potentially broader clinical availability than PET and thus may provide a practical method of routinely evaluating patients. The authors studied eight patients with AD, four healthy elderly controls, and one patient with multi-infarct dementia (MID) using the tracer 123 I-N-isopropyl-p-iodoamphetamine with SPECT

  10. Lung Hot Spot Without Corresponding Computed Tomography Abnormality on Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography: Artifactual or Real, Iatrogenic or Pathologic?

    Science.gov (United States)

    Liu, Yiyan

    Focal lung uptake without corresponding lesions or abnormalities on computed tomography (CT) scan poses a dilemma in the interpretation of fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT). A limited number of case reports have previously suggested an artifactual or iatrogenic nature of the uptake. In the present study, 8 relevant cases were included within a retrospective search of the database. Medical records were reviewed for follow-up radiological and pathologic information. In 7 of 8 cases with focal increased FDG uptake but no corresponding lesions or abnormalities on CT scan, the lung hot spots were artifactual or iatrogenic upon follow-up diagnostic chest CT or repeated PET/CT or both the scans. Microemboli were most likely a potential cause of the pulmonary uptake, with or without partial paravenous injection. One case in the series had a real pulmonary lesion demonstrated on follow-up PET/CT scans and on surgical pathology, although the initial integrated CT and follow-up diagnostic chest CT scans revealed negative findings to demonstrate pulmonary abnormalities corresponding to the hot spot on the PET scan. In conclusion, the finding of a lung hot spot in the absence of anatomical abnormality on FDG PET/CT was most likely artifactual or iatrogenic, but it might also represent a real pulmonary lesion. Nonvisualization of anatomical abnormality could be because of its small size and position directly overlying a segmental vessel. Further image follow-up is necessary and important to clarify the nature of the uptake. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Brain receptor single-photon emission computer tomography with 123I Datscan in Parkinson's disease

    International Nuclear Information System (INIS)

    Minchev, D.; Peshev, N.; Kostadinova, I.; Grigorova, O.; Trindev, P.; Shotekov, P.

    2005-01-01

    Clinical aspects of Parkinson's disease are not enough for the early diagnosis of the disease. Positron emission tomography and the receptor single - photon emission tomography can be used for imaging functional integrity of nigrostriatal dopaminergic structures. 24 patient (17 men and 7 women) were investigated. 20 of them are with Parkinson's disease and 4 are with essential tremor. The radiopharmaceutical - 123I-Datscan (ioflupane, bind with 123I) represent a cocaine analogue with selective affinity to dopamine transporters, located in the dopaminergic nigrostriatal terminals in the striatum. Single - photon emission computer tomography was performed with SPECT gamma camera (ADAC, SH Epic detector). The scintigraphic study was made 3 to 6 hours after intravenous injection of the radiopharmaceutical - 123I- Datscan in dose 185 MBq. 120 frames are registered with duration of each one 22 seconds and gamma camera rotation 360. After generation of transversal slices we generated two composites pictures. The first composite picture image the striatum, the second - the occipital region. Two ratios were calculated representing the uptake of the radiopharmaceutical in the left and right striatum. Qualitative and quantitative criteria were elaborated for evaluating the scintigraphic patterns. Decreased, nonhomogeneous and asymmetric uptake of the radiopharmaceutical coupled with low quantitative parameters in range from 1.44 to 2.87 represents the characteristic scintigraphic pattern for Parkinson's disease with clear clinical picture. Homogenous with high intensity and symmetric uptake of the radiopharmaceutical in the striatum coupled with his clear frontier and with quantitative parameters up to 4.40 represent the scintigraphic pattern in two patients with essential tremor. Receptor single - photon emission computer tomography with 123I - Datscan represents an accurate nuclear-medicine method for precise diagnosis of Parkinson's disease and for its differentiation from

  12. A Comparison of Endoscopic Ultrasound Guided Biopsy and Positron Emission Tomography with Integrated Computed Tomography in Lung Cancer Staging

    DEFF Research Database (Denmark)

    Larsen, Stine Schmidt; Vilmann, P; Krasnik, K

    2009-01-01

    BACKGROUND AND STUDY AIMS: Exact staging of patients with non-small-cell lung cancer (NSCLC) is important to improve selection of resectable and curable patients for surgery. Positron emission tomography with integrated computed tomography (PET/CT) and endoscopic ultrasound guided fine needle...... aspiration biopsy (EUS-FNA) are new and promising methods, but indications in lung cancer staging are controversial. Only few studies have compared the 2 methods. The aim of this study was to assess and compare the diagnostic values of PET/CT and EUS-FNA for diagnosing advanced lung cancer in patients, who...... had both procedures performed. PATIENTS AND METHODS: 27 patients considered to be potential candidates for resection of NSCLC underwent PET/CT and EUS-FNA. Diagnoses were confirmed either by open thoracotomy, mediastinoscopy or clinical follow-up. Advanced lung cancer was defined as tumour...

  13. Imaging spectrum and pitfalls of ¹⁸F-fluorodeoxyglucose positron emission tomography/computed tomography in patients with tuberculosis.

    Science.gov (United States)

    Ito, Kimiteru; Morooka, Miyako; Minamimoto, Ryogo; Miyata, Yoko; Okasaki, Momoko; Kubota, Kazuo

    2013-08-01

    Mycobacterium tuberculosis (TB) is one of the most prominant diseases frequently causing false positive lesions in oncologic surveys using (18)F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT), since TB granulomas are composed of activated macrophages and lymphocytes with high affinity for glucose. These pitfalls of (18)F-FDG PET/CT are important for radiologists. Being familiar with (18)F-FDG images of TB could assist in preventing unfavorable clinical results based on misdiagnoses. In addition, (18)F-FDG PET/CT has the advantage of being able to screen the whole body, and can clearly detect harboring TB lesions as high uptake foci. This article details the spectrum and pitfalls of (18)F-FDG PET/CT imaging in TB.

  14. Contrast-enhanced fluorodeoxyglucose positron emission tomography/computed tomography in solid pseudopapillary neoplasm of the pancreas

    International Nuclear Information System (INIS)

    Santhosh, Sampath; Lakshmanan, Ramesh Kumar; Sonik, Bhavay; Padmavathy, Rajagopalan; Gunaseelan, Rajamani Emmanuel

    2016-01-01

    Solid pseudopapillary neoplasm (SPN) of the pancreas is a rare pancreatic tumor with low malignant potential. It occurs characteristically more often in young women. Radiological and pathological studies have revealed that the tumor is quite different from other pancreatic tumors. Limited information is available in the literature reporting their accumulation of fluorine- 18 fluorodeoxyglucose ( 18 F-FDG) in positron emission tomography/computed tomography (PET/CT). Here, we report a case of pancreatic SPN imaged with contrast-enhanced FDG PET/CT. A percutaneous fine needle aspiration from the metabolically active lesion revealed SPN, and it was confirmed with histopathological results. Recurrence or metastasis was not found after 7 months of follow-up

  15. Benign thyroid and neck lesions mimicking malignancy with false positive findings on positron emission tomography-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Ye Ri; Kim, Shin Young; Lee, Sang Mi [Soonchunhyang University Cheonan Hospital, Cheonan (Korea, Republic of); Lee, Deuk Young [Dept. of Surgery, Younsei Angelot Women' s Clinic, Cheonan (Korea, Republic of)

    2017-02-15

    The increasing use of positron emission tomography-computed tomography (PET/CT) has led to the frequent detection of incidental thyroid and neck lesions with increased 18F-deoxyglucose (FDG) uptake. Although lesions with increased FDG uptake are commonly assumed to be malignant, benign lesions may also exhibit increased uptake. The purpose of this pictorial essay is to demonstrate that benign thyroid and neck lesions can produce false-positive findings on PET/CT, and to identify various difficulties in interpretation. It is crucial to be aware that differentiating between benign and malignant lesions is difficult in a considerable proportion of cases, when relying only on PET/CT findings. Correlation of PET/CT findings with additional imaging modalities is essential to avoid misdiagnosis.

  16. Positron emission tomography-computed tomography standardized uptake values in clinical practice and assessing response to therapy.

    Science.gov (United States)

    Kinahan, Paul E; Fletcher, James W

    2010-12-01

    The use of standardized uptake values (SUVs) is now common place in clinical 2-deoxy-2-[(18)F] fluoro-D-glucose (FDG) position emission tomography-computed tomography oncology imaging and has a specific role in assessing patient response to cancer therapy. Ideally, the use of SUVs removes variability introduced by differences in patient size and the amount of injected FDG. However, in practice there are several sources of bias and variance that are introduced in the measurement of FDG uptake in tumors and also in the conversion of the image count data to SUVs. In this article the overall imaging process is reviewed and estimates of the magnitude of errors, where known, are given. Recommendations are provided for best practices in improving SUV accuracy. Copyright © 2010 Elsevier Inc. All rights reserved.

  17. Lynch Syndrome Associated Colon Adenocarcinoma Resembling Lymphoma on Fluoro-Deoxyglucose-Positron Emission Tomography/Computed Tomography

    International Nuclear Information System (INIS)

    Aparici, Carina Mari; Win, Aung Zaw

    2015-01-01

    The patient was a 46-year-old Asian male diagnosed with lynch syndrome associated colon adenocarcinoma in the right ascending colon. A presurgical staging 18-fluoro-deoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) found increased metabolic activity in the cervical, axillary, mediastinal, supraclavicular, para-aortic and mesenteric lymph nodes. This pattern of metastasis was very unusual for lynch syndrome associated colon adenocarcinoma and the involvement of those lymph nodes resembles the pattern of spread of lymphoma. He underwent right hemicolectomy and he was subsequently treated with 12 cycles of folinic acid (leucovorin), fluorouracil (5-FU), irinotecan. A restaging FDG-PET/CT at the end of the chemotherapy showed interval decrease in size and metabolic activity in the affected lymph nodes. FDG-PET/CT is a useful imaging modality in following-up the treatment response in colon adenocarcinoma

  18. Early-Dynamic Positron Emission Tomography (PET)/Computed Tomography and PET Angiography for Endoleak Detection After Endovascular Aneurysm Repair.

    Science.gov (United States)

    Drescher, Robert; Gühne, Falk; Freesmeyer, Martin

    2017-06-01

    To propose a positron emission tomography (PET)/computed tomography (CT) protocol including early-dynamic and late-phase acquisitions to evaluate graft patency and aneurysm diameter, detect endoleaks, and rule out graft or vessel wall inflammation after endovascular aneurysm repair (EVAR) in one examination without intravenous contrast medium. Early-dynamic PET/CT of the endovascular prosthesis is performed for 180 seconds immediately after intravenous injection of F-18-fluorodeoxyglucose. Data are reconstructed in variable time frames (time periods after tracer injection) to visualize the arterial anatomy and are displayed as PET angiography or fused with CT images. Images are evaluated in view of vascular abnormalities, graft configuration, and tracer accumulation in the aneurysm sac. Whole-body PET/CT is performed 90 to 120 minutes after tracer injection. This protocol for early-dynamic PET/CT and PET angiography has the potential to evaluate vascular diseases, including the diagnosis of complications after endovascular procedures.

  19. 123I-IMP single photon emission computed tomography (SPECT) study in childhood epilepsy

    International Nuclear Information System (INIS)

    Hara, Masafumi; Shimomura, Osamu; Kojima, Akihiro; Izunaga, Hiroshi; Tomiguchi, Seiji; Hirota, Yoshihisa; Taku, Keiichi; Miike, Teruhisa; Takahashi, Mutsumasa

    1990-01-01

    N-isopropyl-p[ 123 I]-iodoamphetamine (IMP) single photon emission computed tomography (SPECT), X-ray computed tomography (X-CT) and magnetic resonance imaging (MRI) were performed in 18 children with idiopathic seizures. In children with idiopathic seizures SPECT identified abnormal lesions in the highest rate (50%) compared with X-CT (11%) and MRI (13%), but the findings of SPECT poorly correlated with the foci on electroencephalography (EEG). Idiopathic epilepsy with abnormal uptake on SPECT was refractory to medical treatments and frequently associated with mental and/or developmental retardation. Perfusion defects identified on SPECT probably influenced the development of the brains in children. IMP SPECT is useful in the diagnosis and medical treatment in children with seizures. (author)

  20. Single-photon emission computed tomography in human immunodeficiency virus encephalopathy: A preliminary report

    International Nuclear Information System (INIS)

    Masdeu, J.C.; Yudd, A.; Van Heertum, R.L.; Grundman, M.; Hriso, E.; O'Connell, R.A.; Luck, D.; Camli, U.; King, L.N.

    1991-01-01

    Depression or psychosis in a previously asymptomatic individual infected with the human immunodeficiency virus (HIV) may be psychogenic, related to brain involvement by the HIV or both. Although prognosis and treatment differ depending on etiology, computed tomography (CT) and magnetic resonance imaging (MRI) are usually unrevealing in early HIV encephalopathy and therefore cannot differentiate it from psychogenic conditions. Thirty of 32 patients (94%) with HIV encephalopathy had single-photon emission computed tomography (SPECT) findings that differed from the findings in 15 patients with non-HIV psychoses and 6 controls. SPECT showed multifocal cortical and subcortical areas of hypoperfusion. In 4 cases, cognitive improvement after 6-8 weeks of zidovudine (AZT) therapy was reflected in amelioration of SPECT findings. CT remained unchanged. SPECT may be a useful technique for the evaluation of HIV encephalopathy

  1. An X-Ray computed tomography/positron emission tomography system designed specifically for breast imaging.

    Science.gov (United States)

    Boone, John M; Yang, Kai; Burkett, George W; Packard, Nathan J; Huang, Shih-ying; Bowen, Spencer; Badawi, Ramsey D; Lindfors, Karen K

    2010-02-01

    Mammography has served the population of women who are at-risk for breast cancer well over the past 30 years. While mammography has undergone a number of changes as digital detector technology has advanced, other modalities such as computed tomography have experienced technological sophistication over this same time frame as well. The advent of large field of view flat panel detector systems enable the development of breast CT and several other niche CT applications, which rely on cone beam geometry. The breast, it turns out, is well suited to cone beam CT imaging because the lack of bones reduces artifacts, and the natural tapering of the breast anteriorly reduces the x-ray path lengths through the breast at large cone angle, reducing cone beam artifacts as well. We are in the process of designing a third prototype system which will enable the use of breast CT for image guided interventional procedures. This system will have several copies fabricated so that several breast CT scanners can be used in a multi-institutional clinical trial to better understand the role that this technology can bring to breast imaging.

  2. Comparison of {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography, hydro-stomach computed tomography, and their combination for detecting primary gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Hye Young; Chung, Woo Suk; Song, E Rang; Kim, Jin Suk [Konyang University Myunggok Medical Research Institute, Konyang University Hospital, Konyang University College of Medicine, Daejeon (Korea, Republic of)

    2015-01-15

    To retrospectively compare the diagnostic accuracy for detecting primary gastric cancer on positron emission tomography/computed tomography (PET/CT) and hydro-stomach CT (S-CT) and determine whether the combination of the two techniques improves diagnostic performance. A total of 253 patients with pathologically proven primary gastric cancer underwent PET/CT and S-CT for the preoperative evaluation. Two radiologists independently reviewed the three sets (PET/CT set, S-CT set, and the combined set) of PET/CT and S-CT in a random order. They graded the likelihood for the presence of primary gastric cancer based on a 4-point scale. The diagnostic accuracy of the PET/CT set, the S-CT set, and the combined set were determined by the area under the alternative-free receiver operating characteristic curve, and sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Diagnostic accuracy, sensitivity, and NPV for detecting all gastric cancers and early gastric cancers (EGCs) were significantly higher with the combined set than those with the PET/CT and S-CT sets. Specificity and PPV were significantly higher with the PET/CT set than those with the combined and S-CT set for detecting all gastric cancers and EGCs. The combination of PET/CT and S-CT is more accurate than S-CT alone, particularly for detecting EGCs.

  3. Comparison of 18F-fluorodeoxyglucose positron emission tomography/computed tomography, hydro-stomach computed tomography, and their combination for detecting primary gastric cancer

    International Nuclear Information System (INIS)

    Jang, Hye Young; Chung, Woo Suk; Song, E Rang; Kim, Jin Suk

    2015-01-01

    To retrospectively compare the diagnostic accuracy for detecting primary gastric cancer on positron emission tomography/computed tomography (PET/CT) and hydro-stomach CT (S-CT) and determine whether the combination of the two techniques improves diagnostic performance. A total of 253 patients with pathologically proven primary gastric cancer underwent PET/CT and S-CT for the preoperative evaluation. Two radiologists independently reviewed the three sets (PET/CT set, S-CT set, and the combined set) of PET/CT and S-CT in a random order. They graded the likelihood for the presence of primary gastric cancer based on a 4-point scale. The diagnostic accuracy of the PET/CT set, the S-CT set, and the combined set were determined by the area under the alternative-free receiver operating characteristic curve, and sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Diagnostic accuracy, sensitivity, and NPV for detecting all gastric cancers and early gastric cancers (EGCs) were significantly higher with the combined set than those with the PET/CT and S-CT sets. Specificity and PPV were significantly higher with the PET/CT set than those with the combined and S-CT set for detecting all gastric cancers and EGCs. The combination of PET/CT and S-CT is more accurate than S-CT alone, particularly for detecting EGCs.

  4. Positron emission tomography-computed tomography protocol considerations for head and neck cancer imaging.

    Science.gov (United States)

    Escott, Edward J

    2008-08-01

    Positron emission tomographic-computed tomographic (PET-CT) imaging of patients with primary head and neck cancers has become an established approach for staging and restaging, as well as radiation therapy planning. The inherent co-registration of PET and CT images made possible by the integrated PET-CT scanner is particularly valuable in head and neck cancer imaging due to the complex and closely situated anatomy in this part of the body, the varied sources of physiologic and benign 2-deoxy-2-[F-18]fluoro-D-glucose (FDG) tracer uptake that occurs in the neck, and the varied and complex posttreatment appearance of the neck. Careful optimization of both the CT and the PET portion of the examination is essential to insure the most accurate and clinically valuable interpretation of these examinations.

  5. (18)F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography in Malignancies of the Thyroid and in Head and Neck Squamous Cell Carcinoma

    DEFF Research Database (Denmark)

    Lauridsen, Jeppe Kiilerich; Rohde, Max; Thomassen, Anders

    2015-01-01

    18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) is a valuable diagnostic tool in a spectrum of malignant and benign conditions, because of a high sensitivity to detect even very small lesions with increased metabolism. This review focuses on the use of FDG...

  6. Patient study of in vivo verification of beam delivery and range, using positron emission tomography and computed tomography imaging after proton therapy

    NARCIS (Netherlands)

    Parodi, Katia; Paganetti, Harald; Shih, Helen A; Michaud, Susan; Loeffler, Jay S; DeLaney, Thomas F; Liebsch, Norbert J; Munzenrider, John E; Fischman, Alan J; Knopf, Antje; Bortfeld, Thomas

    2007-01-01

    PURPOSE: To investigate the feasibility and value of positron emission tomography and computed tomography (PET/CT) for treatment verification after proton radiotherapy. METHODS AND MATERIALS: This study included 9 patients with tumors in the cranial base, spine, orbit, and eye. Total doses of 1.8-3

  7. The added value of 18F-fluorodeoxyglucose positron emission tomography computed tomography in patients with neck lymph node metastases from an unknown primary malignancy.

    Science.gov (United States)

    Prowse, S J B; Shaw, R; Ganeshan, D; Prowse, P M; Hanlon, R; Lewis-Jones, H; Wieshmann, H

    2013-08-01

    The search for a primary malignancy in patients with a metastatic cervical lymph node is challenging yet ultimately of utmost clinical importance. This study evaluated the efficacy of positron emission tomography computed tomography in detecting the occult primary, within the context of a tertiary referral centre head and neck cancer multidisciplinary team tumour board meeting. Thirty-two patients (23 men and 9 women; mean and median age, 61 years) with a metastatic cervical lymph node of unknown primary origin, after clinical examination and magnetic resonance imaging, underwent positron emission tomography computed tomography. The primary tumour detection rate was 50 per cent (16/32). Positron emission tomography computed tomography had a sensitivity of 94 per cent (16/17) and a specificity of 67 per cent (10/15). Combining these results with those of 10 earlier studies of similar patients gave an overall detection rate of 37 per cent. Positron emission tomography computed tomography has become an important imaging modality. To date, it has the highest primary tumour detection rate, for head and neck cancer patients presenting with cervical lymph node metastases from an unknown primary.

  8. Routine Bone Marrow Biopsy Has Little or No Therapeutic Consequence for Positron Emission Tomography/Computed Tomography-Staged Treatment-Naive Patients With Hodgkin Lymphoma

    DEFF Research Database (Denmark)

    El-Galaly, Tarec Christoffer; d'Amore, Francesco; Mylam, Karen Juul

    2012-01-01

    PURPOSETo investigate whether bone marrow biopsy (BMB) adds useful information to [(18)F]fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) staging in patients with Hodgkin lymphoma (HL). PATIENTS AND METHODSNewly diagnosed patients with HL undergoing a pretherapeu...

  9. Coexistence of atrial myxoma and lung cancer on fluorodeoxyglucose positron emission tomography/computed tomography: The impact of distinct fluorodeoxyglucose uptake pattern on differential diagnosis

    International Nuclear Information System (INIS)

    Koc, Kevser; Aras, Mustafa; Inanir, Sabahat

    2014-01-01

    The information regarding fluorodeoxyglucose (FDG) uptake in benign and malignant cardiac tumors is limited in the literature and most of the currrently available data were derived from single case reports. Herein we reported coexistence of atrial myxoma and lung cancer on FDG positron emission tomography/computed tomography with the aim of emphasizing the importance of distinct FDG uptake pattern on differential diagnosis

  10. Diagnostic performance of fluorodeoxyglucose positron emission tomography/magnetic resonance imaging fusion images of gynecological malignant tumors. Comparison with positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Nakajo, Kazuya; Tatsumi, Mitsuaki; Inoue, Atsuo

    2010-01-01

    We compared the diagnostic accuracy of fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) and PET/magnetic resonance imaging (MRI) fusion images for gynecological malignancies. A total of 31 patients with gynecological malignancies were enrolled. FDG-PET images were fused to CT, T1- and T2-weighted images (T1WI, T2WI). PET-MRI fusion was performed semiautomatically. We performed three types of evaluation to demonstrate the usefulness of PET/MRI fusion images in comparison with that of inline PET/CT as follows: depiction of the uterus and the ovarian lesions on CT or MRI mapping images (first evaluation); additional information for lesion localization with PET and mapping images (second evaluation); and the image quality of fusion on interpretation (third evaluation). For the first evaluation, the score for T2WI (4.68±0.65) was significantly higher than that for CT (3.54±1.02) or T1WI (3.71±0.97) (P<0.01). For the second evaluation, the scores for the localization of FDG accumulation showing that T2WI (2.74±0.57) provided significantly more additional information for the identification of anatomical sites of FDG accumulation than did CT (2.06±0.68) or T1WI (2.23±0.61) (P<0.01). For the third evaluation, the three-point rating scale for the patient group as a whole demonstrated that PET/T2WI (2.72±0.54) localized the lesion significantly more convincingly than PET/CT (2.23±0.50) or PET/T1WI (2.29±0.53) (P<0.01). PET/T2WI fusion images are superior for the detection and localization of gynecological malignancies. (author)

  11. Variabilities of Magnetic Resonance Imaging-, Computed Tomography-, and Positron Emission Tomography-Computed Tomography-Based Tumor and Lymph Node Delineations for Lung Cancer Radiation Therapy Planning.

    Science.gov (United States)

    Karki, Kishor; Saraiya, Siddharth; Hugo, Geoffrey D; Mukhopadhyay, Nitai; Jan, Nuzhat; Schuster, Jessica; Schutzer, Matthew; Fahrner, Lester; Groves, Robert; Olsen, Kathryn M; Ford, John C; Weiss, Elisabeth

    2017-09-01

    To investigate interobserver delineation variability for gross tumor volumes of primary lung tumors and associated pathologic lymph nodes using magnetic resonance imaging (MRI), and to compare the results with computed tomography (CT) alone- and positron emission tomography (PET)-CT-based delineations. Seven physicians delineated the tumor volumes of 10 patients for the following scenarios: (1) CT only, (2) PET-CT fusion images registered to CT ("clinical standard"), and (3) postcontrast T1-weighted MRI registered with diffusion-weighted MRI. To compute interobserver variability, the median surface was generated from all observers' contours and used as the reference surface. A physician labeled the interface types (tumor to lung, atelectasis (collapsed lung), hilum, mediastinum, or chest wall) on the median surface. Contoured volumes and bidirectional local distances between individual observers' contours and the reference contour were analyzed. Computed tomography- and MRI-based tumor volumes normalized relative to PET-CT-based volumes were 1.62 ± 0.76 (mean ± standard deviation) and 1.38 ± 0.44, respectively. Volume differences between the imaging modalities were not significant. Between observers, the mean normalized volumes per patient averaged over all patients varied significantly by a factor of 1.6 (MRI) and 2.0 (CT and PET-CT) (P=4.10 × 10 -5 to 3.82 × 10 -9 ). The tumor-atelectasis interface had a significantly higher variability than other interfaces for all modalities combined (P=.0006). The interfaces with the smallest uncertainties were tumor-lung (on CT) and tumor-mediastinum (on PET-CT and MRI). Although MRI-based contouring showed overall larger variability than PET-CT, contouring variability depended on the interface type and was not significantly different between modalities, despite the limited observer experience with MRI. Multimodality imaging and combining different imaging characteristics might be the best approach to define

  12. Increased fluoro-deoxy-D-glucose uptake on positron emission tomography-computed tomography postbronchoalveolar lavage: a potential cause of radiologic misinterpretation.

    LENUS (Irish Health Repository)

    Leong, Sum

    2011-08-01

    Cytologic analysis of bronchoalveolar lavage (BAL) fluid is used for lung cancer diagnosis. We describe a patient with a history of rectal carcinoma who presented with a new lung mass. BAL was performed, with positron emission tomography-computed tomography the following day. There was mildly increased fluoro-deoxy-D-glucose uptake in areas of the lung parenchyma with new ground-glass opacification. This created ambiguity in staging, clarified 2 weeks later by a computed tomography showing complete resolution of the ground-glass opacity. Clinicians should be aware that BAL may cause increased pulmonary fluoro-deoxy-D-glucose uptake, making accurate radiologic interpretation problematic. We suggest that to optimize positron emission tomography-computed tomography, studies should not be performed within 24 hours of BAL.

  13. Comparing staging by positron emission tomography with contrast-enhanced computed tomography and by pathology in head and neck squamous cell carcinoma.

    Science.gov (United States)

    Qualliotine, J R; Mydlarz, W K; Chan, J Y K; Zhou, X; Wang, H; Agrawal, N

    2015-12-01

    This study aimed to evaluate the ability of positron emission tomography with contrast-enhanced computed tomography to correctly stage head and neck squamous cell carcinomas, in comparison with pathological staging. Positron emission tomography computed tomography was used to determine the tumour-node-metastasis classification and overall cancer stage in 85 head and neck squamous cell carcinoma patients who underwent pre-operative imaging using this modality and primary surgery between July 2010 and January 2013. Staging by positron emission tomography computed tomography was retrospectively compared with staging using pathological specimens. Agreement between imaging stage and pathological stage was examined by univariate and multivariate analysis both overall and for each primary tumour site. This imaging modality was 87.5 per cent sensitive and 44.8 per cent specific in identifying regional cervical metastases, and had false positive and false negative rates of 18.8 per cent and 8.2 per cent, respectively. The positive predictive and negative predictive values were 75.4 per cent and 65.0 per cent, respectively. Univariate and multivariate analyses revealed a significant agreement between positron emission tomography computed tomography and pathological node classification in older patients and for the oral cavity primary tumour site. There was significant agreement between both methods in the overall classification only for tumours classified as T3 or greater. Positron emission tomography computed tomography should be used with caution for the pre-operative staging of head and neck cancers because of its high false positive and false negative rates.

  14. DIAGNOSTIC ROLE OF FLUORINE-18 (18F) FLUORODEOXYGLUCOSE POSITRON EMISSION TOMOGRAPHY COMPUTED TOMOGRAPHY IN DETECTING RECURRENT DISEASE IN PATIENTS WITH COLORECTAL CANCER AND ELEVATED CARCINOEMBRYONIC ANTIGEN.

    Science.gov (United States)

    Matovina, Emil; Mihailović, Jasna; Nikoletić, Katarina; Srbovan, Dolores

    2015-01-01

    Early detection of recurrence is an important factor for long term survival of patients with colorectal cancer. Measurement of serum levels of carcinoembryonic antigen has been commonly used in the postoperative surveillance of colorectal cancer. The purpose of this study was to evaluate the ability of positron emission tomography-computed tomography to detect pathological substrate of elevated serum carcinoembryonic antigen in patients with colorectal cancer. The patients with colorectal cancer who underwent curative surgical resection and/ or chemotherapy, who were found in our database, were analyzed retrospectively. Forty-eight 18F-fluorodeoxyglucose positron emission tomography-computed tomography studies including 45 patients (14 women, 31 men; mean age: 62.93 years) with elevated serum, carcinoembryonic antigen levels, which had been performed between January 2011 and January 2014, were evaluated. Serum levels of carcinoembryonic antigen were measured within 3 months after positron emission tomography-computed tomography examination. Final diagnosis of recurrence was made by histopathological findings, radiology studies or clinical follow-up. Recurrences were diagnosed in 37 patients, the prevalence being 77.1%. Liver metastases were found in 18 patients, abdominal, pelvic and/or mediastinal lymph nodes were positive in 19 patients, 11 patients had loco regional recurrences and 4 patients had pulmonary metastasis, and bone metastases were found in one patient. One patient was diagnosed with metastasis in scar tissue. The overall sensitivity and specificity of positron emission tomography-computed tomography was 90.24% and 71.42%, respectively. The positive and negative predictive values were 94.87% and 55.56%, respectively. 18F-fluorodeoxyglucose positron emission tomography-computed tomography is a powerful tool that could be used in determining colorectal cancer recurrence in patients with elevated carcinoembryonic antigen levels and could have an

  15. Left ventricular volume determination from single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Bunker, S.R.; Hartshorne, M.F.; Schmidt, W.P.; Cawthon, M.A.; Karl, R.D. Jr.; Bauman, J.M.; Howard, W.H. III; Rubal, B.J.

    1985-01-01

    To compare the accuracy of single-photon emission computed tomography (SPECT) with that of contrast cineangiography in measuring left ventricular end-diastolic volume, 25 consecutive patients undergoing catheterizaiton for coronary artery or valvular heart disease were first evaluated scintigraphically. SPECT volume values showed a high degree of correlation with those determined by angiography with a standard error of the estimate of 23 ml. SPECT offers a highly accurate and essentially noninvasive method for measuring chamber volumes that is independent of geometric assumptions about ventricular configuration and chest wall attenuation and does not require blood sample counting

  16. Left ventricular volume determination from single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bunker, S.R.; Hartshorne, M.F.; Schmidt, W.P.; Cawthon, M.A.; Karl, R.D. Jr.; Bauman, J.M.; Howard, W.H. III; Rubal, B.J.

    1985-02-01

    To compare the accuracy of single-photon emission computed tomography (SPECT) with that of contrast cineangiography in measuring left ventricular end-diastolic volume, 25 consecutive patients undergoing catheterizaiton for coronary artery or valvular heart disease were first evaluated scintigraphically. SPECT volume values showed a high degree of correlation with those determined by angiography with a standard error of the estimate of 23 ml. SPECT offers a highly accurate and essentially noninvasive method for measuring chamber volumes that is independent of geometric assumptions about ventricular configuration and chest wall attenuation and does not require blood sample counting.

  17. Painful spondylolysis or spondylolisthesis studied by radiography and single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Collier, B.D.; Johnson, R.P.; Carrera, G.F.

    1985-01-01

    Planar bone scintigraphy (PBS) and single-photon emission computed tomography (SPECT) were compared in 19 adults with radiographic evidence of spondylolysis and/or spondylolisthesis. SPECT was more sensitive than PBS when used to identify symptomatic patients and sites of painful defects in the pars interarticularis. In addition, SPECT allowed more accurate localization than PBS. In 6 patients, spondylolysis or spondylolisthesis was unrealted to low back pain, and SPECT images of the posterior neural arch were normal. The authors conclude that when spondylolysis or spondylolisthesis is the cause of low back pain, pars defects are frequently heralded by increased scintigraphic activity which is best detected and localized by SPECT

  18. Image reconstruction using three-dimensional compound Gauss-Markov random field in emission computed tomography

    International Nuclear Information System (INIS)

    Watanabe, Shuichi; Kudo, Hiroyuki; Saito, Tsuneo

    1993-01-01

    In this paper, we propose a new reconstruction algorithm based on MAP (maximum a posteriori probability) estimation principle for emission tomography. To improve noise suppression properties of the conventional ML-EM (maximum likelihood expectation maximization) algorithm, direct three-dimensional reconstruction that utilizes intensity correlations between adjacent transaxial slices is introduced. Moreover, to avoid oversmoothing of edges, a priori knowledge of RI (radioisotope) distribution is represented by using a doubly-stochastic image model called the compound Gauss-Markov random field. The a posteriori probability is maximized by using the iterative GEM (generalized EM) algorithm. Computer simulation results are shown to demonstrate validity of the proposed algorithm. (author)

  19. The display of multiple images derived from emission computed assisted tomography (ECAT)

    International Nuclear Information System (INIS)

    Jackson, P.C.; Davies, E.R.; Goddard, P.R.; Wilde, R.P.H.

    1983-01-01

    In emission computed assisted tomography, a technique has been developed to display the multiple sections of an organ within a single image, such that three dimensional appreciation of the organ can be obtained, whilst also preserving functional information. The technique when tested on phantoms showed no obvious deterioration in resolution and when used clinically gave satisfactory visual results. Such a method should allow easier appreciation of the extent of a lesion through an organ and thus allow dimensions to be obtained by direct measurement. (U.K.)

  20. Special issues in quantitation of brain receptors and related markers by emission computed tomography

    International Nuclear Information System (INIS)

    Links, J.M.

    1998-01-01

    Emission computed tomography provides an opportunity to quantify neurotransmitter-neuro receptor systems in vivo. In order to do so, very high image quality and quantitative accuracy are required. Quantitation of receptor systems involves considerations of physical effects (such as finite spatial resolution, scatter, and attenuation), instrumentation design (such as spatial sampling), image processing (such as filtering), and data analysis (such as kinetic modeling). Appropriate application of these considerations can lead to useful results, but emerging approaches promise even greater levels of accuracy and precision

  1. Painful spondylolysis or spondylolisthesis studied by radiography and single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Collier, B.D.; Johnson, R.P.; Carrera, G.F.; Meyer, G.A.; Schwab, J.P.; Flatley, T.J.; Isitman, A.T.; Hellman, R.S.; Zielonka, J.S.; Knobel, J.

    1985-01-01

    Planar bone scintigraphy (PBS) and single-photon emission computed tomography (SPECT) were compared in 19 adults with radiographic evidence of spondylolysis and/or spondylolisthesis. SPECT was more sensitive than PBS when used to identify symptomatic patients and sites of painful defects in the pars interarticularis. In addition, SPECT allowed more accurate localization than PBS. In 6 patients, spondylolysis or spondylolisthesis was unrealted to low back pain, and SPECT images of the posterior neural arch were normal. The authors conclude that when spondylolysis or spondylolisthesis is the cause of low back pain, pars defects are frequently heralded by increased scintigraphic activity which is best detected and localized by SPECT.

  2. Bronchobiliary Fistula Localized by Cholescintigraphy with Single-Photon Emission Computed Tomography

    International Nuclear Information System (INIS)

    Artunduaga, Maddy; Patel, Niraj R.; Wendt, Julie A.; Guy, Elizabeth S.; Nachiappan, Arun C.

    2015-01-01

    Biliptysis is an important clinical feature to recognize as it is associated with bronchobiliary fistula, a rare entity. Bronchobiliary fistulas have been diagnosed with planar cholescintigraphy. However, cholescintigraphy with single-photon emission computed tomography (SPECT) can better spatially localize a bronchobiliary fistula as compared to planar cholescintigraphy alone, and is useful for preoperative planning if surgical treatment is required. Here, we present the case of a 23-year-old male who developed a bronchobiliary fistula in the setting of posttraumatic and postsurgical infection, which was diagnosed and localized by cholescintigraphy with SPECT

  3. An analysis of regional cerebral blood flow in impulsive murderers using single photon emission computed tomography.

    Science.gov (United States)

    Amen, Daniel G; Hanks, Chris; Prunella, Jill R; Green, Aisa

    2007-01-01

    The authors explored differences in regional cerebral blood flow in 11 impulsive murderers and 11 healthy comparison subjects using single photon emission computed tomography. The authors assessed subjects at rest and during a computerized go/no-go concentration task. Using statistical parametric mapping software, the authors performed voxel-by-voxel t tests to assess significant differences, making family-wide error corrections for multiple comparisons. Murderers were found to have significantly lower relative rCBF during concentration, particularly in areas associated with concentration and impulse control. These results indicate that nonemotionally laden stimuli may result in frontotemporal dysregulation in people predisposed to impulsive violence.

  4. Voluminal modelling for the characterization of wastes packages by gamma emission computed tomography

    International Nuclear Information System (INIS)

    Pettier, J.L.; Thierry, R.

    2001-01-01

    The aim of this work is to model the measurement process used for multi-photon emission computed tomography on nuclear waste drum. Our model MEPHISTO (Multi-Energy PHoton Imagery through Segmented TOmography) takes into account all phenomena influencing gamma emergent flux and high resolution spectrometric measurements using an HpGe detector through a collimator aperture. These phenomena are absorption and Compton scattering of gamma photons in waste drum, geometrical blur, spatial and energetic response of the detector. The analysis of results shows better localisation and quantification performances compared with a Ray-Driven method. It proves the importance of an accurate modelization of collimated measurements to reduce noise and stabilize iterative image reconstructions. (authors)

  5. I-123 iomazenil single photon emission computed tomography for detecting loss of neuronal integrity in patients with traumatic brain injury

    OpenAIRE

    Abiko, Kagari; Ikoma, Katsunori; Shiga, Tohru; Katoh, Chietsugu; Hirata, Kenji; Kuge, Yuji; Kobayashi, Kentaro; Tamaki, Nagara

    2017-01-01

    Background Traumatic brain injury (TBI) causes brain dysfunction in many patients. Using C-11 flumazenil (FMZ) positron emission tomography (PET), we have detected and reported the loss of neuronal integrity, leading to brain dysfunction in TBI patients. Similarly to FMZ PET, I-123 iomazenil (IMZ) single photon emission computed tomography (SPECT) is widely used to determine the distribution of the benzodiazepine receptor (BZR) in the brain cortex. The purpose of this study is to examine whet...

  6. Performance of Positron Emission Tomography and Positron Emission Tomography/Computed Tomography Using Fluorine-18-Fluorodeoxyglucose for the Diagnosis, Staging, and Recurrence Assessment of Bone Sarcoma

    Science.gov (United States)

    Liu, Fanxiao; Zhang, Qingyu; Zhu, Dezhi; Li, Zhenfeng; Li, Jianmin; Wang, Boim; Zhou, Dongsheng; Dong, Jinlei

    2015-01-01

    Abstract To investigate the performance of fluorine-18-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) and PET/computed tomography (CT) in the diagnosis, staging, restaging, and recurrence surveillance of bone sarcoma by systematically reviewing and meta-analyzing the published literature. To retrieve eligible studies, we searched the MEDLINE, Embase, and the Cochrane Central library databases using combinations of following Keywords: “positron emission tomography” or “PET,” and “bone tumor” or “bone sarcoma” or “sarcoma.” Bibliographies from relevant articles were also screened manually. Data were extracted and the pooled sensitivity, specificity, and diagnostic odds ratio (DOR), on an examination-based or lesion-based level, were calculated to appraise the diagnostic accuracy of 18F-FDG PET and PET/CT. All statistical analyses were performed using Meta-Disc 1.4. Forty-two trials were eligible. The pooled sensitivity and specificity of PET/CT to differentiate primary bone sarcomas from benign lesions were 96% (95% confidence interval [CI], 93–98) and 79% (95% CI, 63–90), respectively. For detecting recurrence, the pooled results on an examination-based level were sensitivity 92% (95% CI, 85–97), specificity 93% (95% CI, 88–96), positive likelihood ratio (PLR) 10.26 (95% CI, 5.99–17.60), and negative likelihood ratio (NLR) 0.11 (95% CI, 0.05–0.22). For detecting distant metastasis, the pooled results on a lesion-based level were sensitivity 90% (95% CI, 86–93), specificity 85% (95% CI, 81–87), PLR 5.16 (95% CI, 2.37–11.25), and NLR 0.15 (95% CI, 0.11–0.20). The accuracies of PET/CT for detecting local recurrence, lung metastasis, and bone metastasis were satisfactory. Pooled outcome estimates of 18F-FDG PET were less complete compared with those of PET/CT. 18F-FDG PET and PET/CT showed a high sensitivity for diagnosing primary bone sarcoma. Moreover, PET/CT demonstrated excellent accuracy for the staging

  7. A comparative study of attenuation correction algorithms in single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Murase, Kenya; Itoh, Hisao; Mogami, Hiroshi; Ishine, Masashiro; Kawamura, Masashi; Iio, Atsushi; Hamamoto, Ken

    1987-01-01

    A computer based simulation method was developed to assess the relative effectiveness and availability of various attenuation compensation algorithms in single photon emission computed tomography (SPECT). The effect of the nonuniformity of attenuation coefficient distribution in the body, the errors in determining a body contour and the statistical noise on reconstruction accuracy and the computation time in using the algorithms were studied. The algorithms were classified into three groups: precorrection, post correction and iterative correction methods. Furthermore, a hybrid method was devised by combining several methods. This study will be useful for understanding the characteristics limitations and strengths of the algorithms and searching for a practical correction method for photon attenuation in SPECT. (orig.)

  8. Positron emission tomography

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.

    1985-01-01

    This book contains 24 selections. Some of the titles are: Positron Emission Tomography Instrumentation, Generator Systems for Positron Emitters, Reconstruction Algorithms, Cerebral Glucose Consumption: Methodology and Validation, Cerebral Blood Flow Tomography Using Xenon-133 Inhalation: Methods and Clinical Applications, PET Studies of Stroke, Cardiac Positron Emission Tomography, and Use of PET in Oncology

  9. Positron emission tomography

    International Nuclear Information System (INIS)

    Yamamoto, Y.L.; Thompson, C.J.; Diksic, M.; Meyer, E.; Feindel, W.H.

    1984-01-01

    One of the most exciting new technologies introduced in the last 10 yr is positron emission tomography (PET). PET provides quantitative, three-dimensional images for the study of specific biochemical and physiological processes in the human body. This approach is analogous to quantitative in-vivo autoradiography but has the added advantage of permitting non-invasive in vivo studies. PET scanning requires a small cyclotron to produce short-lived positron emitting isotopes such as oxygen-15, carbon-11, nitrogen-13 and fluorine-18. Proper radiochemical facilities and advanced computer equipment are also needed. Most important, PET requires a multidisciplinary scientific team of physicists, radiochemists, mathematicians, biochemists and physicians. The most recent trends are reviewed in the imaging technology, radiochemistry, methodology and clinical applications of positron emission tomography. (author)

  10. Effects of Respiration-Averaged Computed Tomography on Positron Emission Tomography/Computed Tomography Quantification and its Potential Impact on Gross Tumor Volume Delineation

    International Nuclear Information System (INIS)

    Chi, Pai-Chun Melinda; Mawlawi, Osama; Luo Dershan; Liao Zhongxing; Macapinlac, Homer A.; Pan Tinsu

    2008-01-01

    Purpose: Patient respiratory motion can cause image artifacts in positron emission tomography (PET) from PET/computed tomography (CT) and change the quantification of PET for thoracic patients. In this study, respiration-averaged CT (ACT) was used to remove the artifacts, and the changes in standardized uptake value (SUV) and gross tumor volume (GTV) were quantified. Methods and Materials: We incorporated the ACT acquisition in a PET/CT session for 216 lung patients, generating two PET/CT data sets for each patient. The first data set (PET HCT /HCT) contained the clinical PET/CT in which PET was attenuation corrected with a helical CT (HCT). The second data set (PET ACT /ACT) contained the PET/CT in which PET was corrected with ACT. We quantified the differences between the two datasets in image alignment, maximum SUV (SUV max ), and GTV contours. Results: Of the patients, 68% demonstrated respiratory artifacts in the PET HCT , and for all patients the artifact was removed or reduced in the corresponding PET ACT . The impact of respiration artifact was the worst for lesions less than 50 cm 3 and located below the dome of the diaphragm. For lesions in this group, the mean SUV max difference, GTV volume change, shift in GTV centroid location, and concordance index were 21%, 154%, 2.4 mm, and 0.61, respectively. Conclusion: This study benchmarked the differences between the PET data with and without artifacts. It is important to pay attention to the potential existence of these artifacts during GTV contouring, as such artifacts may increase the uncertainties in the lesion volume and the centroid location

  11. DE-BLURRING SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY IMAGES USING WAVELET DECOMPOSITION

    Directory of Open Access Journals (Sweden)

    Neethu M. Sasi

    2016-02-01

    Full Text Available Single photon emission computed tomography imaging is a popular nuclear medicine imaging technique which generates images by detecting radiations emitted by radioactive isotopes injected in the human body. Scattering of these emitted radiations introduces blur in this type of images. This paper proposes an image processing technique to enhance cardiac single photon emission computed tomography images by reducing the blur in the image. The algorithm works in two main stages. In the first stage a maximum likelihood estimate of the point spread function and the true image is obtained. In the second stage Lucy Richardson algorithm is applied on the selected wavelet coefficients of the true image estimate. The significant contribution of this paper is that processing of images is done in the wavelet domain. Pre-filtering is also done as a sub stage to avoid unwanted ringing effects. Real cardiac images are used for the quantitative and qualitative evaluations of the algorithm. Blur metric, peak signal to noise ratio and Tenengrad criterion are used as quantitative measures. Comparison against other existing de-blurring algorithms is also done. The simulation results indicate that the proposed method effectively reduces blur present in the image.

  12. Assessment of left ventricular function by electrocardiogram-gated myocardial single photon emission computed tomography using quantitative gated single photon emission computed tomography software

    International Nuclear Information System (INIS)

    Morita, Koichi; Adachi, Itaru; Konno, Masanori

    1999-01-01

    Electrocardiogram (ECG)-gated myocardial single photon emission computed tomography (SPECT) can assess left ventricular (LV) perfusion and function easily using quantitative gated SPECT (QGS) software. ECG-gated SPECT was performed in 44 patients with coronary artery disease under post-stress and resting conditions to assess the values of LV functional parameters, by comparison to LV ejection fraction derived from gated blood pool scan and myocardial characteristics. A good correlation was obtained between ejection fraction using QGS and that using cardiac blood pool scan (r=0.812). Some patients with myocardial ischemia had lower ejection fraction under post-stress compared to resting conditions, indicating post-stress LV dysfunction. LV wall motion and wall thickening were significantly impaired in ischemic and infarcted myocardium, and the degree of abnormality in the infarcted areas was greater than in the ischemia area. LV functional parameters derived using QGS were useful to assess post-stress LV dysfunction and myocardial viability. In conclusion, ECG-gated myocardial SPECT permits simultaneous quantitative assessment of myocardial perfusion and function. (author)

  13. Computer tomography, magnetic resonance imaging, and positron emission tomography or positron emission tomography/computer tomography for detection of metastatic lymph nodes in patients with ovarian cancer: A meta-analysis

    International Nuclear Information System (INIS)

    Yuan Ying; Gu Zhaoxiang; Tao Xiaofeng; Liu Shiyuan

    2012-01-01

    Objectives: To compare the diagnostic performances of computed tomography (CT), magnetic resonance (MR) imaging, and positron emission tomography (PET or PET/CT) for detection of metastatic lymph nodes in patients with ovarian cancer. Methods: Relevant studies were identified with MEDLINE and EMBASE from January 1990 to July 2010. We estimated the weighted summary sensitivities, specificities, OR (odds ratio), and summary receiver operating characteristic (sROC) curves of each imaging technique and conducted pair-wise comparisons using the two-sample Z-test. Meta-regression, subgroup analysis, and funnel plots were also performed to explain the between-study heterogeneity. Results: Eighteen eligible studies were included, with a total of 882 patients. PET or PET/CT was a more accurate modality (sensitivity, 73.2%; specificity, 96.7%; OR [odds ratio], 90.32). No significant difference was detected between CT (sensitivity, 42.6%; specificity, 95.0%; OR, 19.87) and MR imaging (sensitivity, 54.7%; specificity, 88.3%; OR, 12.38). Meta-regression analyses and subgroup analyses revealed no statistical difference. Funnel plots with marked asymmetry suggested a publication bias. Conclusion: FDG-PET or FDG-PET/CT is more accurate than CT and MR imaging in the detection of lymph node metastasis in patients with ovarian cancer.

  14. {sup 18}F-fluorodeoxyglucose positron emission tomography-computed tomography in the management of adult multisystem Langerhans cell histiocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Obert, Julie [Universite Paris Diderot, Paris (France); Assistance Publique-Hopitaux de Paris, Centre National de Reference de l' Histiocytose Langerhansienne, Service de Pneumologie, Hopital Saint-Louis, Paris (France); Vercellino, Laetitia [Assistance Publique-Hopitaux de Paris, Service de Medecine Nucleaire, Hopital Saint-Louis, Paris (France); Van der Gucht, Axel [Universite Paris Diderot, Paris (France); Assistance Publique-Hopitaux de Paris, Service de Medecine Nucleaire, Hopital Saint-Louis, Paris (France); De Margerie-Mellon, Constance [Universite Paris Diderot, Paris (France); Assistance Publique-Hopitaux de Paris, Service de Radiologie, Hopital Saint-Louis, Paris (France); Bugnet, Emmanuelle; Lorillon, Gwenael [Assistance Publique-Hopitaux de Paris, Centre National de Reference de l' Histiocytose Langerhansienne, Service de Pneumologie, Hopital Saint-Louis, Paris (France); Chevret, Sylvie [Universite Paris Diderot, Paris (France); Assistance Publique-Hopitaux de Paris, Service de Biostatistique et Information Medicale, Hopital Saint-Louis, Paris (France); Biostatistics and Clinical Epidemiology Research Team, U1153 CRESS, Paris (France); Tazi, Abdellatif [Universite Paris Diderot, Paris (France); Assistance Publique-Hopitaux de Paris, Centre National de Reference de l' Histiocytose Langerhansienne, Service de Pneumologie, Hopital Saint-Louis, Paris (France); Biostatistics and Clinical Epidemiology Research Team, U1153 CRESS, Paris (France)

    2017-04-15

    The standard evaluation of multisystem Langerhans cell histiocytosis (LCH) includes a clinical evaluation, laboratory tests and a skeleton/skull X-ray survey, with chest high-resolution computed tomography (HRCT) in the case of pulmonary involvement. Preliminary reports suggest that {sup 18}F-fluorodeoxyglucose positron emission tomography-computed tomography ({sup 18}F-FDG PET-CT) may be useful for evaluating patients with LCH. Fourteen consecutive adult patients with multisystem LCH were included in this retrospective study, and were evaluated using standard procedures and {sup 18}F-FDG PET-CT. The two sets of findings were compared both at baseline and during follow-up. Serial HRCT and pulmonary function tests were used to evaluate outcome in patients with lung involvement. At the baseline evaluation, PET-CT identified every LCH localization found with the standard evaluation (except a mild cecum infiltration). PET-CT showed additional lesions in seven patients, mostly involving bones, and differentiated inactive from active lesions. Thyroid {sup 18}F-FDG uptake was identified in three cases. No pituitary stalk {sup 18}F-FDG uptake was observed in patients with pituitary LCH. Only 3/12 (25 %) patients with pulmonary LCH displayed moderate pulmonary {sup 18}F-FDG uptake. During follow-up, variations (≥50 % of maximum standardized uptake) in bone {sup 18}F-FDG uptake intensity were correlated with disease state and response to treatment. The absence of lung {sup 18}F-FDG uptake did not preclude lung function improvement after treatment. Except for cases with pulmonary and pituitary involvement, {sup 18}F-FDG PET-CT could replace the standard evaluation for staging of adult patients with multisystem LCH. Serial PET-CT scans are useful for evaluating treatment responses, particularly in cases with bone LCH involvement. (orig.)

  15. Low Accuracy of Computed Tomography and Positron Emission Tomography to Detect Lung and Lymph Node Metastases of Colorectal Cancer.

    Science.gov (United States)

    Guerrera, Francesco; Renaud, Stéphane; Schaeffer, Mickaël; Nigra, Victor; Solidoro, Paolo; Santelmo, Nicola; Filosso, Pier Luigi; Falcoz, Pierre-Emmanuel; Ruffini, Enrico; Oliaro, Alberto; Massard, Gilbert

    2017-10-01

    Minimally invasive surgery, stereotactic radiotherapy, and radiofrequency ablation are commonly proposed in the case of pulmonary colorectal-metastasis as alternatives to conventional open surgery. Preoperative imaging assessment by computed tomography (CT) scan and fluorodeoxyglucose positron emission tomography (FDG-PET) are critical to guide oncologic radical treatment. Our aim was to investigate the accuracy of CT and FDG-PET for the evaluation of the number of pulmonary colorectal metastases and thoracic lymph nodal involvement (LNI). Patients who underwent lung surgical resection for pulmonary colorectal metastases from 2004 to 2014 were analyzed. Concordance between histology, CT scan, and FDG-PET findings were assessed. Data of 521 patients were analyzed. Of those, FDG-PET was performed in 435 (83.5%). A moderate agreement between both CT scan (kappa index: 0.42) and FDG-PET (kappa index: 0.42) findings and the histologically proven number of metastases was observed. The number of histologically proven metastases was correctly discriminated in 61.7% of cases with CT scan and in 61.8% of cases with FDG-PET. Multiple metastases were discovered in 20.9% of clinical single metastasis cases with CT scan, and in 24.4% of those cases with FDG-PET. One hundred fifty patients (29.1%) presented with pathologic LNI. A poor agreement was observed between LNI and CT scan findings (kappa index: 0.02), and a weak agreement was observed concerning LNI and FDG-PET findings (kappa index: 0.39). Computed tomography and FDG-PET have limitations if the objective is to detect all malignant nodules and to discriminate the LNI in cases of pulmonary metastases of colorectal cancer. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Multiaxial tomography of heart chambers by gated blood-pool emission computed tomography using a rotating gamma camera

    International Nuclear Information System (INIS)

    Tamaki, N.; Mukai, T.; Ishii, Y.; Yonekura, Y.; Yamamoto, K.; Kadota, K.; Kambara, H.; Kawai, C.; Torizuka, K.

    1983-01-01

    Fifteen patients and three volunteers underwent radionuclide blood-pool cardiac studies with electrocardiographic gating. Following conventional planar-gated imaging (anterior and left anterior oblique projections), emission computed tomography (ECT), using a rotating gamma camera, was performed.A series of transaxial tomograms of the cardiac chambers was obtained. The left ventricular short-axis plane, long-axis plane, and four-chamber-view plane were then reorganized; each chamber was visualized separately. Compared to gated planar imaging, this technique showed regional asynergy more clearly in patients with myocardial infarction and demonstrated dilatation of the atria and ventricles more accurately in patients with an atrial septal defect and valvular heart diseases. In addition, when a section of the heart is otained at any angle with gated blood pool ECT, three-dimensional assessment of cardiac chambers in motion is more precise; mutual superimposition becomes unnecessary

  17. Asymmetrically increased rib cage uptake on bone scintigraphy: Incidental detection of pleural mesothelioma on single photon emission computed tomography/computed tomography

    International Nuclear Information System (INIS)

    Dhull, Varun Singh; Sharma, Punit; Durgapal, Prashant; Karunanithi, Sellam; Tripathi, Madhavi; Kumar, Rakesh

    2014-01-01

    Follow-up bone scintigraphy (BS) in a patient of carcinoma left breast, who was treated with surgery followed by radiotherapy 12 years back, revealed asymmetrically increased radiotracer uptake in left-sided ribs. Since, this pattern was atypical for metastatic rib involvement, single photon emission computed tomography/computed tomography (SPECT/CT) of thorax was done in the same setting which revealed circumferential nodular left-sided pleural thickening. Biopsy confirmed it to be pleural mesothelioma. Left-sided ribs showed no abnormality on CT, thus suggesting the rib uptake as reactive in nature. This pattern of asymmetric rib uptake on BS should be kept in mind and warrants further investigation for determining underlying pathology

  18. A case of dual ectopy thyroid along the thyroglossal tract demonstrated on 99mTc-Pertechnatate hybrid single photon emission computed tomography/computed tomography

    International Nuclear Information System (INIS)

    Agarwal, Krishan Kant; Karunanithi, Sellam; Jain, Sachin; Tripathi, Madhavi

    2014-01-01

    Ectopic thyroid tissue (ETT) refers to the presence of thyroid tissue in locations other than the normal anterior neck region between the second and fourth tracheal cartilages. Multiple ectopia of the thyroid is extremely rare. Here we report a case of 10-year-old girl with anterior midline neck swelling and hypothyroidism with dual ectopia of thyroid gland without orthotopic thyroid gland. Planar 99 m-technetium pertechnatate scan identified ETT corresponding to the palpable neck swelling. Single photon emission computed tomography/computed tomography (SPECT/CT) demonstrated ETT in two locations, one corresponding to the palpable mass and another in the in the sublingual location. This case thus demonstrates the important role of hybrid SPECT/CT in the identification of dual ectopia along the thyroglossal tract

  19. Degenerative dementia: nosological aspects and results of single photon emission computed tomography; Les demences degeneratives: aspects nosologiques et resultats de la tomographie d'emission monophotonique

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, B.; Habert, M.O. [Hopital Pitie-Salpetriere, 75 - Paris (France)

    1999-12-01

    Ten years ago, the diagnosis discussion of a dementia case for the old patient was limited to two pathologies: the Alzheimer illness and the Pick illness. During these last years, the frame of these primary degenerative dementia has fallen into pieces. The different diseases and the results got with single photon emission computed tomography are discussed. for example: fronto-temporal dementia, primary progressive aphasia, progressive apraxia, visio-spatial dysfunction, dementia at Lewy's bodies, or cortico-basal degeneration. (N.C.)

  20. [Positron emission tomography combined with computed tomography in the initial evaluation and response assessment in primary central nervous system lymphoma].

    Science.gov (United States)

    Mercadal, Santiago; Cortés-Romera, Montserrat; Vélez, Patricia; Climent, Fina; Gámez, Cristina; González-Barca, Eva

    2015-06-08

    To evaluate the role of positron emission tomography combined with computed tomography (PET-CT) in the initial evaluation and response assessment in primary central nervous system lymphoma (PCNSL). Fourteen patients (8 males) with a median age 59.5 years diagnosed of PCNSL. A brain PET-CT and magnetic resonance imaging (MRI) were performed in the initial evaluation. In 7 patients a PET-CT after treatment was performed. PET-CT showed at diagnosis 31 hypermetabolic focuses and MRI showed 47 lesions, with a good grade of concordance between both (k = 0.61; P = .005). In the response assessment, correlation between both techniques was good, and PET-CT was helpful in the appreciation of residual MRI lesions. Overall survival at 2 years of negative vs. positive PET-CT at the end of treatment was 100 vs. 37.5%, respectively (P = .045). PET-CT can be useful in the initial evaluation of PCNSL, and especially in the assessment of response. Despite the fact that PET-CT detects less small lesions than MRI, a good correlation between MRI and PET-CT was observed. It is effective in the evaluation of residual lesions. Prospective studies are needed to confirm their possible prognostic value. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  1. The role of positron emission tomography/computed tomography imaging with radiolabeled choline analogues in prostate cancer.

    Science.gov (United States)

    Navarro-Pelayo Láinez, M M; Rodríguez-Fernández, A; Gómez-Río, M; Vázquez-Alonso, F; Cózar-Olmo, J M; Llamas-Elvira, J M

    2014-11-01

    prostate cancer is the most frequent solid malignant tumor in Western Countries. Positron emission tomography/x-ray computed tomography imaging with radiolabeled choline analogues is a useful tool for restaging prostate cancer in patients with rising prostate-specific antigen after radical treatment (in whom conventional imaging techniques have important limitations) as well as in the initial assessment of a selected group of prostate cancer patients. For this reason a literature review is necessary in order to evaluate the usefulness of this imaging test for the diagnosis and treatment of prostate cancer. a MEDLINE (PubMed way) literature search was performed using the search parameters: «Prostate cancer» and «Choline-PET/CT». Other search terms were «Biochemical failure» and/or «Staging» and/or «PSA kinetics». English and Spanish papers were selected; original articles, reviews, systematic reviews and clinical guidelines were included. according to available data, radiolabeled choline analogues plays an important role in the management of prostate cancer, especially in biochemical relapse because technique accuracy is properly correlated with prostate-specific antigen values and kinetics. Although is an emerging diagnostic technique useful in treatment planning of prostate cancer, final recommendations have not been submitted. Copyright © 2013 AEU. Published by Elsevier Espana. All rights reserved.

  2. The Medical Case for a Positron Emission Tomography and X-ray Computed Tomography Combined Service in Oman.

    Science.gov (United States)

    Al-Bulushi, Naima K; Bailey, Dale; Mariani, Giuliano

    2013-11-01

    The value of a positron emission tomography and X-ray computed tomography (PET/CT) combined service in terms of diagnostic accuracy, cost-effectiveness and impact on clinical decision-making is well-documented in the literature. Its role in the management of patients presenting with cancer is shifting from early staging and restaging to the early assessment of the treatment response. Currently, the application of PET/CT has extended to non-oncological specialties-mainly neurology, cardiology and rheumatology. A further emerging application for PET/CT is the imaging of infection/inflammation. This article illustrates some of the PET/CT applications in both oncological and non-oncological disorders. In view of the absence of this modality in Oman, this article aims to increase the awareness of the importance of these imaging modalities and their significant impact on diagnosis and management in both oncological and non-oncological specialties for patients of all age groups as well as the decision-makers.

  3. Seeing the Unseen—Bioturbation in 4D: Tracing Bioirrigation in Marine Sediment Using Positron Emission Tomography and Computed Tomography

    Science.gov (United States)

    Delefosse, Matthieu; Kristensen, Erik; Crunelle, Diane; Braad, Poul Erik; Dam, Johan Hygum; Thisgaard, Helge; Thomassen, Anders; Høilund-Carlsen, Poul Flemming

    2015-01-01

    Understanding spatial and temporal patterns of bioirrigation induced by benthic fauna ventilation is critical given its significance on benthic nutrient exchange and biogeochemistry in coastal ecosystems. The quantification of this process challenges marine scientists because faunal activities and behaviors are concealed in an opaque sediment matrix. Here, we use a hybrid medical imaging technique, positron emission tomography and computed tomography (PET/CT) to provide a qualitative visual and fully quantitative description of bioirrigation in 4D (space and time). As a study case, we present images of porewater advection induced by the well-studied lugworm (Arenicola marina). Our results show that PET/CT allows more comprehensive studies on ventilation and bioirrigation than possible using techniques traditionally applied in marine ecology. We provide a dynamic three-dimensional description of bioirrigation by the lugworm at very high temporal and spatial resolution. Results obtained with the PET/CT are in agreement with literature data on lugworm ventilation and bioirrigation. Major advantages of PET/CT over methods commonly used are its non-invasive and non-destructive approach and its capacity to provide information that otherwise would require multiple methods. Furthermore, PET/CT scan is versatile as it can be used for a variety of benthic macrofauna species and sediment types and it provides information on burrow morphology or animal behavior. The lack of accessibility to the expensive equipment is its major drawback which can only be overcome through collaboration among several institutions. PMID:25837626

  4. Advantages of 18F-fluorodeoxyglucose positron emission tomography combined with computed tomography in detecting post cardiac surgery infections.

    Science.gov (United States)

    Adjtoutah, Djamel; Azhari, Alaa; Larabi, Youcef; Dorigo, Enrica; Merlin, Charles; Marcaggi, Xavier; Nana, Armel Simplice; Camilleri, Lionel; Azarnoush, Kasra

    2014-01-01

    The 18F-fluorodeoxyglucose positron emission tomography combined with computed tomography (FDG-PET/CT) offers an excellent negative predictive value. Consequently, it is a reliable tool for excluding an infectious phenomenon in case of negativity. In case of persistent fever of unknown origin after cardiac surgery and in combination with other bacteriological examinations and medical imaging, we can rely on FDG-PET/CT to confirm or eliminate deep infections and prosthetic endocarditis. For this reason, FDG-PET/CT should be considered among the examinations to be performed in case of suspected infection after cardiac surgery. We have reported the case of a 76-year-old man who presented with a fever of unknown origin and recurrent septic shocks after a biological Bentall procedure combined with left anterior descending (LAD) coronary artery revascularization by the left internal thoracic artery. We performed a FDG-PET/CT which showed external iliac vein and right common femoral vein hyperfixation with infiltration of adjacent soft tissues, highly suspected to be an infectious process. The aim of this case report is to show that FDG-PET/CT, in combination with other bacteriological examinations and medical imaging, can be extremely helpful in detecting deep infectious sources, even during the early postoperative period.

  5. Therapeutic impact of [18F]fluoride positron-emission tomography/computed tomography on patients with unclear foot pain

    International Nuclear Information System (INIS)

    Fischer, Dorothee Rita; Hesselmann, Rolf; Johayem, Anass; Hany, Thomas F.; Schulthess, Gustav K. von; Strobel, Klaus; Maquieira, Gerardo J.; Espinosa, Norman; Zanetti, Marco

    2010-01-01

    To evaluate the therapeutic impact of [ 18 F]fluoride positron-emission tomography/computed tomography ([ 18 F]fluoride PET/CT) imaging on patients with unclear foot pain. Twenty-eight patients were prospectively included in this study. Therapeutic management was defined by two experienced dedicated foot surgeons before and after [ 18 F]fluoride PET/CT imaging. Twenty-six patients underwent cross-sectional imaging [CT, magnetic resonance (MR)] prior to PET/CT. A retrospective analysis of the magnetic resonance imaging (MRI) diagnoses was performed when a therapy change occurred after PET/CT imaging. In 13/28 (46%) patients therapeutic management was changed due to PET/CT results. Management changes occurred in patients with the following diagnoses: os trigonum syndrome; sinus tarsi syndrome; os tibiale externum syndrome; osteoarthritis of several joints; non-consolidated fragments; calcaneo-navicular coalition; plantar fasciitis; insertional tendinopathy; suggestion of periostitis; neoarticulations between metatarsal bones. Os trigonum, os tibiale externum, subtalar osteoarthritis and plantar fasciitis were only seen to be active on PET/CT images but not on MR images. [ 18 F]fluoride PET/CT has a substantial therapeutic impact on management in patients with unclear foot pain. (orig.)

  6. Technetium-99m methylene diphosphonate uptake in the brachialis muscle hematoma in a patient with prostate cancer and coagulation disorder mimicking bone metastasis evaluated by single-photon emission tomography-computed tomography/computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kamaleshwaran, Koramadai Karuppusamy; Mohanan, Vyshakh; Shinto, Ajit Sugunan, E-mail: dr.kamaleshwar@gmail.com [Department of Nuclear Medicine and PET/CT, Kovai Medical Centre and Hospital Limited, Coimbatore (India); Madhavan, Devdas [Department of Urology, Comprehensive Cancer Care Centre, Kovai Medical Centre and Hospital Limited, Coimbatore (India)

    2013-10-15

    We report a case of 79-year-old male with prostate cancer and coagulation disorder presented with left shoulder pain. He underwent bone scintigraphy to rule out metastasis, which showed intense foci of tracer activity in the left axilla. Hybrid single-photon emission tomography-computed tomography (SPECT/CT) of the shoulder region localized tracer uptake to the left brachialis muscle hematoma. (author)

  7. Technetium-99m methylene diphosphonate uptake in the brachialis muscle hematoma in a patient with prostate cancer and coagulation disorder mimicking bone metastasis evaluated by single-photon emission tomography-computed tomography/computed tomography

    International Nuclear Information System (INIS)

    Kamaleshwaran, Koramadai Karuppusamy; Mohanan, Vyshakh; Shinto, Ajit Sugunan; Madhavan, Devdas

    2013-01-01

    We report a case of 79-year-old male with prostate cancer and coagulation disorder presented with left shoulder pain. He underwent bone scintigraphy to rule out metastasis, which showed intense foci of tracer activity in the left axilla. Hybrid single-photon emission tomography-computed tomography (SPECT/CT) of the shoulder region localized tracer uptake to the left brachialis muscle hematoma. (author)

  8. Scintigraphic appearance of focal fatty infiltration of the liver using single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Kudo, M.; Hirasa, M.; Ibuki, Y.

    1984-01-01

    Fatty infiltration of the liver had been considered to assume a uniform distribution until quite recently. However, the development of X-ray computed tomography (XCT) and the ultrasound (US) has proven that fatty infiltration of the liver may sometimes assume a nonuniform distribution (focal fatty infiltration (FFI)). This investigation was undertaken to evaluate the scintigraphic appearance of FFI using single-photon emission computed tomography (SPECT) with a GE Maxicamera 400T. Radionuclide images including SPECT were evaluated in 12 cases with FFI which were diagnosed by XCT and US. Most of them were histrogically confirmed to be positive fatty infiltration in the liver. The results were as follows. The fatty infiltrated area was visualized as a hot spot in one case, a defect in 2 cases, a low uptake in one case and a normal uptake in 8 cases. Radionuclide imaging of FFI shows a large variety of findings and it suggests that Kupffer cell function varies with the causes or stage of fatty infiltration. And one can understand the pathological state of FFI from a viewpoint of Kupffer cell function only by radionuclide imaging including SPECT, which is very useful to compare the images with XCT images

  9. The identification of spinal pathology in chronic low back pain using single photon emission computed tomography

    International Nuclear Information System (INIS)

    Ryan, R.J.; Gibson, T.; Fogelman, I.

    1992-01-01

    Single photon emission computed tomography (SPECT) findings were investigated in 80 consecutive patients (aged 18-70 years, median 44) referred to a rheumatology outpatient clinic with low back pain persisting for more than 3 months. Lesions of the lumbar spine were demonstrated in 60% of patients using SPECT but in only 35% with planar imaging. Fifty-one per cent of all lesions were only detected by SPECT, and lesions visualized on SPECT could be precisely localized to the vertebral body, or different parts of the posterior elements. Fifty per cent of lesions involved the facetal joints of which almost 60% were identified on SPECT alone. X-rays of the lumbar spine, with posterior oblique views, failed to demonstrate abnormalities corresponding to almost all SPECT posterior element lesions although it identified abnormalities corresponding to over 60% of anterior SPECT lesions. Computed tomography (CT) was performed in 30 patients with a SPECT lesion and sites of facetal joint activity corresponded to facetal osteoarthritis in 82%. (author)

  10. Influence of 18F-fluorodeoxyglucose-positron emission tomography on computed tomography-based radiation treatment planning for oesophageal cancer

    International Nuclear Information System (INIS)

    Everitt, C.; Leong, T.

    2006-01-01

    The addition of positron emission tomography (PET) information to CT-based radiotherapy treatment planning has the potential to improve target volume definition through more accurate localization of the primary tumour and involved regional lymph nodes. This case report describes the first patient enrolled to a prospective study evaluating the effects of coregistered positron emission tomography/CT images on radiotherapy treatment planning for oesophageal cancer. The results show that if combined positron emission tomography/CT is used for radiotherapy treatment planning, there may be alterations to the delineation of tumour volumes when compared to CT alone. For this patient, a geographic miss of tumour would have occurred if CT data alone were used for radiotherapy planning Copyright (2006) Blackwell Publishing Asia Pty Ltd

  11. Prostate cancer nodal oligometastasis accurately assessed using prostate-specific membrane antigen positron emission tomography-computed tomography and confirmed histologically following robotic-assisted lymph node dissection.

    Science.gov (United States)

    O'Kane, Dermot B; Lawrentschuk, Nathan; Bolton, Damien M

    2016-01-01

    We herein present a case of a 76-year-old gentleman, where prostate-specific membrane antigen positron emission tomography-computed tomography (PSMA PET-CT) was used to accurately detect prostate cancer (PCa), pelvic lymph node (LN) metastasis in the setting of biochemical recurrence following definitive treatment for PCa. The positive PSMA PET-CT result was confirmed with histological examination of the involved pelvic LNs following pelvic LN dissection.

  12. Post meningitis subdural hygroma: Anatomical and functional evaluation with 99mTc-ehylene cysteine dimer single photon emission tomography/computed tomography

    OpenAIRE

    Sharma, Punit; Mishra, Ajiv; Arora, Geetanjali; Tripathi, Madhavi; Bal, Chandrasekhar; Kumar, Rakesh

    2013-01-01

    Subdural hygroma is the collection of cerebrospinal fluid in the subdural space. Most often these resolve spontaneously. However, in cases with neurological complications surgical drainage may be needed. We here, present the case of an 8-year-old boy with post meningitis subdural hygroma. 99mTc-ehylene cysteine dimer (99mTc-ECD) hybrid single photon emission tomography/computed tomography (SPECT/CT) carried out in this patient, demonstrated the subdural hygroma as well as the associated cereb...

  13. Unusual presentation of metastatic carcinoma cervix with clinically silent primary identified by 18F-flouro deoxy glucose positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Senthil, Raja; Mohapatra, Ranjan Kumar; Srinivas, Shripriya; Sampath, Mouleeswaran Koramadai; Sundaraiya, Sumati

    2016-01-01

    Carcinoma cervix is the most common gynecological malignancy among Indian women. The common symptoms at presentation include abnormal vaginal bleeding, unusual discharge from the vagina, or pain during coitus and postmenopausal bleeding. Rarely, few patients may present with distant metastases without local symptoms. We present two patients with an unusual presentation of metastatic disease without any gynecological symptoms, where 18 F-flouro deoxy glucose positron emission tomography/computed tomography helped in identifying the primary malignancy in the uterine cervix

  14. Review of cardiovascular imaging in the journal of nuclear cardiology in 2015. Part 1 of 2: Plaque imaging, positron emission tomography, computed tomography, and magnetic resonance.

    Science.gov (United States)

    AlJaroudi, Wael A; Hage, Fadi G

    2016-02-01

    In 2015, many original articles pertaining to cardiovascular imaging with impressive quality were published in the Journal of Nuclear Cardiology. In a set of 2 articles, we provide an overview of these contributions to facilitate for the interested reader a quick review of the advancements that occurred in the field over this year. In this first article, we focus on arterial plaque imaging, cardiac positron emission tomography, computed tomography, and magnetic resonance imaging.

  15. Rare case of isolated splenic metastases from gastric cancer detected with fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Kamaleshwaran, Koramadai Karuppusamy; Shibu, Deepu; Sugunan Shinto, Ajit; Sivanesan, Balasubramanian

    2013-01-01

    We report a rare case of isolated splenic metastasis from gastric cancer detected with fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography (PET/CT). A 55-year-old man with gastric cancer 1 year post surgery, evaluated with PET/CT showed focal, intense uptake in the spleen, with no other abnormal findings. On splenectomy, the lesion was confirmed as metastasis from gastric cancer pathologically. (author)

  16. Fluorodeoxyglucose positron emission tomography?computed tomography in evaluation of pelvic and para-aortic nodal involvement in early stage and operable cervical cancer: Comparison with surgicopathological findings

    OpenAIRE

    Bansal, Vandana; Damania, Kaizad; Sharma, Anshu Rajnish

    2011-01-01

    Introduction: Nodal metastases in cervical cancer have prognostic implications. Imaging is used as an adjunct to clinical staging for evaluation of nodal metastases. Fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) has an advantage of superior resolution of its CT component and detecting nodal disease based on increased glycolytic activity rather than node size. But there are limited studies describing its limitations in early stage cervical cancers. Objectiv...

  17. Prostate cancer nodal oligometastasis accurately assessed using prostate-specific membrane antigen positron emission tomography-computed tomography and confirmed histologically following robotic-assisted lymph node dissection

    Directory of Open Access Journals (Sweden)

    Dermot B O′Kane

    2016-01-01

    Full Text Available We herein present a case of a 76-year-old gentleman, where prostate-specific membrane antigen positron emission tomography-computed tomography (PSMA PET-CT was used to accurately detect prostate cancer (PCa, pelvic lymph node (LN metastasis in the setting of biochemical recurrence following definitive treatment for PCa. The positive PSMA PET-CT result was confirmed with histological examination of the involved pelvic LNs following pelvic LN dissection.

  18. 18F-FLT Positron Emission Tomography/Computed Tomography Imaging in Pancreatic Cancer: Determination of Tumor Proliferative Activity and Comparison with Glycolytic Activity as Measured by 18F-FDG Positron Emission Tomography/Computed Tomography Imaging

    Directory of Open Access Journals (Sweden)

    Senait Aknaw Debebe

    2016-02-01

    Full Text Available Objective: This phase-I imaging study examined the imaging characteristic of 3’-deoxy-3’-(18F-fluorothymidine (18F-FLT positron emission tomography (PET in patients with pancreatic cancer and comparisons were made with (18F-fluorodeoxyglucose (18F-FDG. The ultimate aim was to develop a molecular imaging tool that could better define the biologic characteristics of pancreas cancer, and to identify the patients who could potentially benefit from surgical resection who were deemed inoperable by conventional means of staging. Methods: Six patients with newly diagnosed pancreatic cancer underwent a combined FLT and FDG computed tomography (CT PET/CT imaging protocol. The FLT PET/CT scan was performed within 1 week of FDG PET/CT imaging. Tumor uptake of a tracer was determined and compared using various techniques; statistical thresholding (z score=2.5, and fixed standardized uptake value (SUV thresholds of 1.4 and 2.5, and applying a threshold of 40% of maximum SUV (SUVmax and mean SUV (SUVmean. The correlation of functional tumor volumes (FTV between 18F-FDG and 18F-FLT was assessed using linear regression analysis. Results: It was found that there is a correlation in FTV due to metabolic and proliferation activity when using a threshold of SUV 2.5 for FDG and 1.4 for FLT (r=0.698, p=ns, but a better correlation was obtained when using SUV of 2.5 for both tracers (r=0.698, p=ns. The z score thresholding (z=2.5 method showed lower correlation between the FTVs (r=0.698, p=ns of FDG and FLT PET. Conclusion: Different tumor segmentation techniques yielded varying degrees of correlation in FTV between FLT and FDGPET images. FLT imaging may have a different meaning in determining tumor biology and prognosis.

  19. Single photon emission computed tomography study of human pulmonary perfusion: preliminary findings

    Energy Technology Data Exchange (ETDEWEB)

    Carratu, L; Sofia, M [Naples Univ. (Italy). Facolta di Medicina e Chirurgia; Salvatore, M; Muto, P; Ariemma, G [Istituto Nazionale per la Prevenzione, Lo Studio e La Cura dei Tumori Fondazione Pascale, Naples (Italy); Lopez-Majano, V [Cook County Hospital, Chicago, IL (USA). Nuclear Medicine Div.

    1984-02-01

    Single photon emission computed tomography (SPECT) was performed with /sup 99/Tcsup(m)-albumin macroaggregates to study human pulmonary perfusion in healthy subjects and patients with respiratory diseases such as chronic obstructive pulmonary disease (COPD) and lung neoplasms. The reconstructed SPECT data was displayed in coronal, transverse, sagittal plane sections and compared to conventional perfusion scans. The SPECT data gave more complicated anatomical information about the extent of damage and morphology of the pulmonary vascular bed. In healthy subjects and COPD patients, qualitative and quantitative assessment of pulmonary perfusion could be obtained from serial SPECT scans with respect to distribution and relative concentration of the injected radiopharmaceutical. Furthermore, SPECT of pulmonary perfusion has been useful in detecting the extent of damage to the pulmonary circulation. This is useful for the preoperative evaluation and staging of lung cancer.

  20. Evaluation of a 99Tcm bound brain scanning agent for single photon emission computed tomography

    DEFF Research Database (Denmark)

    Andersen, A R; Hasselbalch, S G; Paulson, O B

    1986-01-01

    D,L HM-PAO-99Tcm (PAO) is a lipophilic tracer complex which is avidly taken up by the brain. We have compared the regional distribution of PAO with regional cerebral blood flow (CBF). CBF was measured by single photon emission computed tomography (SPECT) by Tomomatic 64 after 133Xe inhalation in 41...... patients. With the same SPECT the distribution of PAO was measured after intravenous injection. High resolution (HR) and low resolution (LR) studies were performed yielding a resolution of 6-10 mm (HR) and 15-20 mm (LR). PAO images showed close resemblance to 133Xe CBF tomograms. Only 20 per cent...... of the (decay corrected) brain counts were lost during 24 hours....

  1. Differentiation of malignant glioma and metastatic brain tumor by thallium-201 single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kojima, Yasuhiro; Kuwana, Nobumasa; Noji, Masato; Tosa, Junichi [Yokohama Minami Kyosai Hospital (Japan)

    1994-09-01

    The use of superdelayed thallium-201 single photon emission computed tomography ([sup 201]Tl SPECT) for differentiating malignant gliomas from cerebral metastases was investigated in 23 patients (7 with meningioma, 6 with glioma, 7 with cerebral metastasis, 1 with each of neurinoma, abscess, and necrosis). 4 mCi of [sup 201]Tl was injected intravenously, and gamma camera scans were performed after 10 minutes and 4, 24, 72, and 96 hours (superdelayed scan). The mean thallium index of meningiomas was significantly higher than those of gliomas and cerebral metastases after 10 minutes, while the mean thallium indices of meningiomas and gliomas were significantly higher than those of cerebral metastases after 96 hours. The combination of early and superdelayed [sup 201]Tl SPECT may be useful in differentiating malignant gliomas from cerebral metastases. (author).

  2. Hot water epilepsy: Phenotype and single photon emission computed tomography observations

    Directory of Open Access Journals (Sweden)

    Mehul Patel

    2014-01-01

    Full Text Available We studied the anatomical correlates of reflex hot water epilepsy (HWE using multimodality investigations viz. magnetic resonance imaging (MRI, electroencephalography (EEG, and single photon emission computed tomography (SPECT. Five men (mean age: 27.0 ΁ 5.8 years with HWE were subjected to MRI of brain, video-EEG studies, and SPECT scan. These were correlated with phenotypic presentations. Seizures could be precipitated in three patients with pouring of hot water over the head and semiology of seizures was suggestive of temporal lobe epilepsy. Ictal SPECT showed hyperperfusion in: left medial temporal - one, left lateral temporal - one, and right parietal - one. Interictal SPECT was normal in all five patients and did not help in localization. MRI and interictal EEG was normal in all the patients. The clinical and SPECT studies suggested temporal lobe as the seizure onset zone in some of the patients with HWE.

  3. Brain perfusion single photon emission computed tomography in major psychiatric disorders: From basics to clinical practice

    International Nuclear Information System (INIS)

    Santra, Amburanjan; Kumar, Rakesh

    2014-01-01

    Brain single photon emission computed tomography (SPECT) is a well-established and reliable method to assess brain function through measurement of regional cerebral blood flow (rCBF). It can be used to define a patient's pathophysiological status when neurological or psychiatric symptoms cannot be explained by anatomical neuroimaging findings. Though there is ample evidence validating brain SPECT as a technique to track human behavior and correlating psychiatric disorders with dysfunction of specific brain regions, only few psychiatrists have adopted brain SPECT in routine clinical practice. It can be utilized to evaluate the involvement of brain regions in a particular patient, to individualize treatment on basis of SPECT findings, to monitor the treatment response and modify treatment, if necessary. In this article, we have reviewed the available studies in this regard from existing literature and tried to present the evidence for establishing the clinical role of brain SPECT in major psychiatric illnesses

  4. Studies of left ventricular volume estimation from single photon emission computed tomography

    International Nuclear Information System (INIS)

    Hiraki, Yoshio; Shimizu, Mitsuharu; Joja, Ikuo; Aono, Kaname; Yanagi, Hidekiyo; Indo, Haruaki; Seno, Yoshimasa; Teramoto, Shigeru; Nagaya, Isao.

    1988-01-01

    We studied the comparative accuracy of 99m Tc cardiac blood pool Single Photon Emission Computed Tomography (SPECT) for the measurement of left ventricular volume in 20 patients undergoing SPECT and single plane contrast left ventriculography (LVG). Left ventricular volume was calculated based on the total number of voxels in left ventricle. End-diastolic left ventricular volume (EDV) and end-systolic left ventricular volume (ESV) calculated from SPECT were compared with those from LVG. SPECT volume values showed a high degree of correlation with those by LVG (r = 0.923 for EDV, r = 0.903 for ESV). We appreciated the usefulness and accuracy of SPECT in measuring left ventricular volume because of its three-dimensional information. (author)

  5. Diagnosis of coronary stenosis using thallium-201 myocardial emission computed tomography

    International Nuclear Information System (INIS)

    Ito, Tsunaaki; Takeda, Hiroshi; Maeda, Hisato; Nakagawa, Tsuyoshi; Yamaguchi, Nobuo; Makino, Katsutoshi; Futagami, Yasuo; Konishi, Tokuji

    1985-01-01

    Thallium-201 myocardial emission computed tomography (ECT) was described with respect to methods of correcting ECT data and reconstructing the images, qualitative and quantitative diagnosis in the detection of coronary stenosis. Although 201 Tl myocardial ECT (using circumferential profile method combined with washout method) has relatively high diagnostic sensitivity, the correction of absorption is not satisfactory yet. Inside absorption coefficient is considered uniform by regarding the human body as oval shape. However, the chest, including the heart, lungs, vertebrae and thoracic wall, has four different absorption coefficients. If absorption can be corrected accurately, it will be possible to completely assess the myocardial blood flow by measuring the regional myocardial uptake of thallium-201. (Namekawa, K.)

  6. Brain perfusion single photon emission computed tomography in children after acute encephalopathy

    International Nuclear Information System (INIS)

    Kurihara, Mana; Nakae, Yoichiro; Kohagizawa, Toshitaka; Eto, Yoshikatsu

    2005-01-01

    We studied single photon emission computed tomography (SPECT) of 15 children with acute encephalopathy after more than 1 year from the onset, using technetium-99 m-L, L-ethyl cystinate dimer ( 99m Tc-ECD) and a three-dementional stereotaxic region of interest template. Regional cerebral blood flow was evaluated and divided in three groups according to the severity of disability: absent or mild, moderate, and severe. There was no abnormality on SPECT in the patients without disability or with mild disability. Diffuse hypoperfusion was shown in the groups with moderate and severe disability. The patients with severe disability showed hypoperfusion in the pericallosal, frontal and central areas which was more pronounced than in the patients with moderate disability. (author)

  7. Detection of avascular necrosis in adults by single photon emission computed tomography

    International Nuclear Information System (INIS)

    Collier, B.D.; Johnston, R.P.; Carrera, G.; Isitman, A.T.; Hellman, R.S.; Zielonka, J.S.

    1984-01-01

    Twenty-one adult patients with the clinical diagnosis of avascular necrosis (AVN) of the femoral head were examined with planar bone scintigraphy (high resolution collimator) and single photon emission computed tomography (SPECT). The duration of hip pain ranged from 1 day to 18 months. Risk factors (including steroids, renal transplantation, alcoholism, and trauma) were present in 17 cases. A final diagnosis of AVN (20 hips), osteochondral facture, or stress fracture, was established for 17 patients. The 4 remaining patients, who were radiographically normal and did not complain of pain 3 months later, were thought to have no significant bone pathology. SPECT and planar bone scintigraphy were reported as positive for AVN only if a photopenic bony defect could be identified. In particular, uniformly increased activity throughout the femoral head was not considered to be diagnostic of AVN. The authors conclude that by identifying a photopenic defect which is not evident on planar bone scintigraphy, SPECT can contribute to accurate diagnosis of AVN

  8. Fluorine-18 Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Imaging in Patients With Carcinoma of the Nasopharynx: Diagnostic Accuracy and Impact on Clinical Management

    International Nuclear Information System (INIS)

    Gordin, Arie; Golz, Avishay; Daitzchman, Marcello; Keidar, Zohar; Bar-Shalom, Rachel; Kuten, Abraham; Israel, Ora

    2007-01-01

    Purpose: To assess the value of 18 F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in patients with nasopharyngeal carcinoma as compared with PET and conventional imaging (CI) alone, and to assess the impact of PET/CT on further clinical management. Methods and Materials: Thirty-three patients with nasopharyngeal carcinoma had 45 PET/CT examinations. The study was a retrospective analysis. Changes in patient care resulting from the PET/CT studies were recorded. Results: Positron emission tomography/computed tomography had sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 92%, 90%, 90%, 90%, and 91%, respectively, as compared with 92%, 65%, 76%, 86%, and 80% for PET and 92%, 15%, 60%, 60%, and 60% for CI. Imaging with PET/CT altered further management of 19 patients (57%). Imaging with PET/CT eliminated the need for previously planned diagnostic procedures in 11 patients, induced a change in the planned therapeutic approach in 5 patients, and guided biopsy to a specific metabolically active area inside an edematous region in 3 patients, thus decreasing the chances for tissue sampling errors and avoiding damage to nonmalignant tissue. Conclusions: In cancer of the nasopharynx, the diagnostic performance of PET/CT is better than that of stand-alone PET or CI. Positron emission tomography/computed tomography had a major impact on further clinical management in 57% of patients

  9. Stimulated Emission Computed Tomography (NSECT) images enhancement using a linear filter in the frequency domain

    Energy Technology Data Exchange (ETDEWEB)

    Viana, Rodrigo S.S.; Tardelli, Tiago C.; Yoriyaz, Helio, E-mail: hyoriyaz@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Jackowski, Marcel P., E-mail: mjack@ime.usp.b [University of Sao Paulo (USP), SP (Brazil). Dept. of Computer Science

    2011-07-01

    In recent years, a new technique for in vivo spectrographic imaging of stable isotopes was presented as Neutron Stimulated Emission Computed Tomography (NSECT). In this technique, a fast neutrons beam stimulates stable nuclei in a sample, which emit characteristic gamma radiation. The photon energy is unique and is used to identify the emitting nuclei. The emitted gamma energy spectra can be used for reconstruction of the target tissue image and for determination of the tissue elemental composition. Due to the stochastic nature of photon emission process by irradiated tissue, one of the most suitable algorithms for tomographic reconstruction is the Expectation-Maximization (E-M) algorithm, once on its formulation are considered simultaneously the probabilities of photons emission and detection. However, a disadvantage of this algorithm is the introduction of noise in the reconstructed image as the number of iterations increases. This increase can be caused either by features of the algorithm itself or by the low sampling rate of projections used for tomographic reconstruction. In this work, a linear filter in the frequency domain was used in order to improve the quality of the reconstructed images. (author)

  10. Stimulated Emission Computed Tomography (NSECT) images enhancement using a linear filter in the frequency domain

    International Nuclear Information System (INIS)

    Viana, Rodrigo S.S.; Tardelli, Tiago C.; Yoriyaz, Helio; Jackowski, Marcel P.

    2011-01-01

    In recent years, a new technique for in vivo spectrographic imaging of stable isotopes was presented as Neutron Stimulated Emission Computed Tomography (NSECT). In this technique, a fast neutrons beam stimulates stable nuclei in a sample, which emit characteristic gamma radiation. The photon energy is unique and is used to identify the emitting nuclei. The emitted gamma energy spectra can be used for reconstruction of the target tissue image and for determination of the tissue elemental composition. Due to the stochastic nature of photon emission process by irradiated tissue, one of the most suitable algorithms for tomographic reconstruction is the Expectation-Maximization (E-M) algorithm, once on its formulation are considered simultaneously the probabilities of photons emission and detection. However, a disadvantage of this algorithm is the introduction of noise in the reconstructed image as the number of iterations increases. This increase can be caused either by features of the algorithm itself or by the low sampling rate of projections used for tomographic reconstruction. In this work, a linear filter in the frequency domain was used in order to improve the quality of the reconstructed images. (author)

  11. An economic evaluation of positron emission tomography (PET) and positron emission tomography/computed tomography (PET/CT) for the diagnosis of breast cancer recurrence.

    Science.gov (United States)

    Auguste, P; Barton, P; Hyde, C; Roberts, T E

    2011-04-01

    To review the published economic studies that have evaluated positron emission tomography/computed tomography (PET/CT) in the treatment of recurrent breast cancer, and to develop and carry out a model-based economic evaluation to investigate the relative cost-effectiveness of PET/CT to detect breast cancer recurrence compared with conventional work-up. A systematic review of economic and diagnostic evidence for PET/CT in diagnosis of breast cancer recurrence. The original databases searched include MEDLINE (Ovid) (1950 to week 5 May 2009), EMBASE (Ovid) (1980 to 2009 week 22) and the NHS Economic Evaluation Database. An updated search was conducted for each database from May 2009 to week 4 April 2010. A decision tree was developed in TREEAGE software (TreeAge Software Inc., Williamstown, MA, USA). The relevant data on accuracy, sensitivity and specificity of each diagnostic test were linked in the model, to costs and the primary outcome measure, cost per quality-adjusted life-year (QALY). The model estimated the mean cost associated with each diagnostic procedure and assumed that patients entering the model were aged 50-75 years. The results of the cost-effectiveness analysis are presented in terms of the incremental cost-effectiveness ratios (ICERs). The ICER for the strategy of PET compared with conventional work-up was estimated at £29,300 per QALY; the ICER for PET/CT compared with PET was £ 31,000 per QALY; and the ICER for PET/CT combined with conventional work-up versus PET/CT was £ 42,100. Clearly, for each additional diagnostic test that is added to PET, the more expensive the package becomes, but also the more effective it becomes in terms of QALYs gained. The probabilistic sensitivity analysis shows that at a willingness-to-pay threshold of £ 20,000 per QALY, conventional work-up is the preferred option. Only data from indirect comparisons are available from the accuracy review, and there is some uncertainty about whether the data defining the

  12. Clinical applications of 18F-fluorodeoxyglucose positron emission tomography/computed tomography in carcinoma of unknown primary

    Institute of Scientific and Technical Information of China (English)

    HU Man; YU Jin-ming; ZHAO Wei; ZHANG Pin-liang; JU Gui-fang; FU Zheng; ZHANG Guo-li; KONG Li; YANG Yan-qin; MA Yi-dong

    2011-01-01

    Background Carcinoma of unknown primary (CUP) encompasses a heterogeneous group of tumors with varying clinical features. The management of patients of CUP remains a clinical challenge. The purpose of this study was to evaluate the clinical applications of integrated 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) information in patients with CUP,including detecting the occult primary tumor and effecting on disease therapy.Methods One hundred and forty-nine patients with histologically-proven metastases of CUP were included. For all patients,the conventional diagnostic work-up was unsuccessful in localizing the primary site. Whole-body PET/CT images were obtained approximately 60 minutes after intravenous injection of 350-425 MBq of 18F-FDG.Results In 24.8% of patients,FDG PET/CT detected primary tumors that were not apparent after conventional workup.In this group of patients,the overall sensitivity,specificity,and accuracy rates of FDG PET/CT in detecting unknown primary tumors were 86.0%,87.7%,and 87.2%,respectively. FDG PET/CT imaging also led to the detection of previously unrecognized metastases in 29.5% of patients. Forty-seven (31.5%,47 of 149) patients underwent a change in therapeutic management.Conclusions FDG PET/CT is a valuable tool in patients with CUP,because it assisted in detecting unknown primary tumors and previously unrecognized distant metastases,and optimized the mangement of these patients.

  13. Computed tomography myocardial perfusion vs {sup 15}O-water positron emission tomography and fractional flow reserve

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Michelle C.; Dweck, Marc R.; Golay, Saroj K. [University of Edinburgh/British Heart Foundation Centre for Cardiovascular Science, Edinburgh (United Kingdom); Mirsadraee, Saeed; Weir, Nicholas W.; Fletcher, Alison; Lucatelli, Christophe; Reid, John H. [University of Edinburgh, Clinical Research Imaging Centre, Edinburgh (United Kingdom); MacGillivray, Tom; Van Beek, Edwin J.R.; Newby, David E. [University of Edinburgh/British Heart Foundation Centre for Cardiovascular Science, Edinburgh (United Kingdom); University of Edinburgh, Clinical Research Imaging Centre, Edinburgh (United Kingdom); Cruden, Nicholas L.; Henriksen, Peter A.; Uren, Neal [Edinburgh Heart Centre, Royal Infirmary of Edinburgh, Edinburgh (United Kingdom); McKillop, Graham; Patel, Dilip [Department of Radiology, Royal Infirmary of Edinburgh, Edinburgh (United Kingdom); Lima, Joao A.C. [Johns Hopkins Hospital, Departments of Medicine and Radiology, Baltimore, MD (United States)

    2017-03-15

    Computed tomography (CT) can perform comprehensive cardiac imaging. We compared CT coronary angiography (CTCA) and CT myocardial perfusion (CTP) with {sup 15}O-water positron emission tomography (PET) and invasive coronary angiography (ICA) with fractional flow reserve (FFR). 51 patients (63 (61-65) years, 80 % male) with known/suspected coronary artery disease (CAD) underwent 320-multidetector CTCA followed by ''snapshot'' adenosine stress CTP. Of these 22 underwent PET and 47 ICA/FFR. Obstructive CAD was defined as CTCA stenosis >50 % and CTP hypoperfusion, ICA stenosis >70 % or FFR <0.80. PET hyperaemic myocardial blood flow (MBF) was lower in obstructive than non-obstructive territories defined by ICA/FFR (1.76 (1.32-2.20) vs 3.11 (2.44-3.79) mL/(g/min), P < 0.001) and CTCA/CTP (1.76 (1.32-2.20) vs 3.12 (2.44-3.79) mL/(g/min), P < 0.001). Baseline and hyperaemic CT attenuation density was lower in obstructive than non-obstructive territories (73 (71-76) vs 86 (84-88) HU, P < 0.001 and 101 (96-106) vs 111 (107-114) HU, P 0.001). PET hyperaemic MBF corrected for rate pressure product correlated with CT attenuation density (r = 0.579, P < 0.001). There was excellent per-patient sensitivity (96 %), specificity (85 %), negative predictive value (90 %) and positive predictive value (94 %) for CTCA/CTP vs ICA/FFR. CT myocardial attenuation density correlates with {sup 15}O-water PET MBF. CTCA and CTP can accurately identify obstructive CAD. (orig.)

  14. Application of positron emission tomography-computed tomography in the diagnosis of pulmonary ground-glass nodules.

    Science.gov (United States)

    Hu, Lili; Pan, Yuanwei; Zhou, Zhigang; Gao, Jianbo

    2017-11-01

    The aim of the present study was to investigate the value of positron emission tomography-computed tomography (PET-CT) using 18 F-fluorodeoxyglucose in the clinical diagnosis of pulmonary ground-glass nodule. In total, 54 patients with pulmonary GGN that were identified by PET-CT examination were selected and confirmed by pathology and clinical diagnosis in hospital between April 2014 and April 2015. The association between PET-CT findings and pathology, and the value of PET-CT were then evaluated. In the 54 patients, solitary pulmonary GGN with a nodule diameter of between 0.6 and 2.0 cm were detected. Amongst them, the PET-CT examination of 42 patients revealed hyper metabolic nodules, and were all mixed GGN type nodules with a diameter >1 cm. The PET-CT examination of the remaining 12 patients demonstrated no evidence of metabolic abnormalities and the nodules in these patients were pure or mixed GGN with a diameter <1 cm (except 2 cases with a diameter ≥1 cm). Furthermore, the diagnoses for all patients were pathologically confirmed by CT-guided needle biopsy or thoracoscopic surgical resection. Amongst them, there were 41 cases of lung adenocarcinoma, 4 cases of fungal infection, 7 cases of inflammation and 2 cases of adenomatoid hyperplasia. Additionally, PET-CT has a lower detection rate for smaller GGN exhibits no clear advantage for pure GGN, but has a higher detection rate for larger GGN. In conclusion, to a certain extent, PET-CT makes up for the shortcomings of traditional imaging and has some clinical value for the diagnosis of GGN.

  15. Standardized uptake value on positron emission tomography/computed tomography predicts prognosis in patients with locally advanced pancreatic cancer.

    Science.gov (United States)

    Wang, Si-Liang; Cao, Shuo; Sun, Yu-Nan; Wu, Rong; Chi, Feng; Tang, Mei-Yue; Jin, Xue-Ying; Chen, Xiao-Dong

    2015-10-01

    The aim of the present study was to investigate the use and value of maximum standardized uptake value (SUV max) on positron emission tomography/computed tomography (PET/CT) images as a prognostic marker for patients with locally advanced pancreatic cancer (LAPC). The medical records of all consecutive patients who underwent PET/CT examination in our institution were retrospectively reviewed. Inclusion criteria were histologically or cytologically proven LAPC. Patients with distant metastasis were excluded. For statistical analysis, the SUV max of primary pancreatic cancer was measured. Survival rates were calculated using the Kaplan-Meier method, and multivariable analysis was performed to determine the association of SUV max with overall survival (OS) and progression-free survival (PFS) using a Cox proportional hazards model. Between July 2006 and June 2013, 69 patients were enrolled in the present study. OS and PFS were 14.9 months [95% confidence interval (CI) 13.1-16.7] and 8.3 months (95% CI 7.1-9.5), respectively. A high SUV max (>5.5) was observed in 35 patients, who had significantly worse OS and PFS than the remaining patients with a low SUV max (P = 0.025 and P = 0.003). Univariate analysis showed that SUV max and tumor size were prognostic factors for OS, with a hazard ratio of 1.90 and 1.81, respectively. A high SUV max was an independent prognostic factor, with a hazard ratio of 1.89 (95% CI 1.015-3.519, P = 0.045). The present study suggests that increased SUV max is a predictor of poor prognosis in patients with LAPC.

  16. Diagnostic accuracy of (18) F-methylcholine positron emission tomography/computed tomography for intra- and extrahepatic hepatocellular carcinoma.

    Science.gov (United States)

    Bieze, Matthanja; Klümpen, Heinz-Josef; Verheij, Joanne; Beuers, Ulrich; Phoa, Saffire S K S; van Gulik, Thomas M; Bennink, Roelof J

    2014-03-01

    Diagnosis of hepatocellular carcinoma (HCC) primarily involves imaging. The aim of this study was to assess the accuracy of (18) F-fluorocholine ((18) F-FCH) positron emission tomography (PET) for detection of HCC and evaluation of extent of disease. Patients with HCC >1 cm were included between 2009 and July 2011, and follow-up closed in February 2013. Diagnosis was based on American Association for the Study of Liver Diseases criteria, and all patients underwent (18) F-FCH PET/computed tomography (CT) at baseline before treatment, 6 underwent a second PET/CT posttreatment, and 1 a third during follow-up. Whole-body PET and low-dose CT imaging were performed 15 minutes after (18) F-FCH injection. Evaluation of imaging was done with standardized uptake value (SUV) ratios: SUV maximum of the lesion divided by the SUV mean of surrounding tissue. Statistical analyses included descriptive analyses, receiver operating characteristic curve, McNemar's test, and Kaplan-Meier's test at 5% level of significance. Twenty-nine patients revealed 53 intrahepatic lesions. In 48 of 53 lesions, (18) F-FCH PET was positive (SUVratio , 1.95 ± 0.66; sensitivity, 88%; specificity, 100%). PET/CT showed uptake in 18 extrahepatic lesions and no uptake in 3 lesions affirmed non-HCC lesions; all lesions were confirmed with additional investigation (accuracy, 100%). In 17 of 29 patients, additional lesions were found on PET/CT imaging, with implications for treatment in 15 patients. Posttreatment PET/CT showed identical results, compared with standard treatment evaluation. This study shows additional value of (18) F-FCH PET/CT for patients with HCC. (18) F-FCH PET/CT has implications for staging, management, and treatment evaluation because of accurate assessment of extrahepatic disease. © 2014 by the American Association for the Study of Liver Diseases.

  17. Differences in fluorodeoxyglucose positron emission tomography/computed tomography findings between elderly onset rheumatoid arthritis and polymyalgia rheumatica.

    Science.gov (United States)

    Takahashi, Hiroyuki; Yamashita, Hiroyuki; Kubota, Kazuo; Miyata, Yoko; Okasaki, Momoko; Morooka, Miyako; Takahashi, Yuko; Kaneko, Hiroshi; Kano, Toshikazu; Mimori, Akio

    2015-07-01

    To compare the fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) findings in patients with elderly-onset rheumatoid arthritis (EORA) with those in patients with polymyalgia rheumatica (PMR), two conditions with similar clinical presentations. We retrospectively analyzed the FDG-PET/CT findings in 10 patients with EORA and 27 patients with PMR admitted to our department between 2006 and 2012. No significant difference was observed in the median patient ages at the time of FDG-PET/CT scans in the EORA and PMR groups (73.5 vs. 78.0 years, respectively). Significant differences in both FDG uptake scores and standardized uptake values were observed between the two groups in the ischial tuberosities, spinous processes, and wrists. No significant differences were detected in the shoulders and hips. However, specific uptake patterns were observed in each group: circular and linear uptake patterns were observed around the humeral head in the EORA group, whereas focal and non-linear uptake patterns were observed in the PMR group. Moreover, focal uptake in front of the hip joint, indicating iliopectineal bursitis, tended to be limited to the PMR group. High sensitivity (92.6%) and specificity (90%) were observed for PMR diagnoses when at least three of the following five items were satisfied: characteristic findings of shoulder and iliopectineal bursitis, FDG uptake in ischial tuberosities and spinal spinous processes, and lack of FDG uptake in the wrists. The differences in the degree of uptake at each lesion and in uptake patterns at the shoulders and hips are potentially useful for obtaining a definitive diagnosis.

  18. (18)F-FDG positron-emission tomography/computed tomography findings of radiographic lesions suggesting old healed tuberculosis.

    Science.gov (United States)

    Jeong, Yun-Jeong; Paeng, Jin Chul; Nam, Hyun-Yeol; Lee, Ji Sun; Lee, Sang-Min; Yoo, Chul-Gyu; Kim, Young Whan; Han, Sung Koo; Yim, Jae-Joon

    2014-03-01

    The presence of radiographic lesions suggesting old healed tuberculosis (TB) is one of the strongest risk factors for the subsequent development of active TB. We elucidated the metabolic activity of radiographic lesions suggesting old healed TB using (18)F-fluorodeoxyglucose positron emission tomography/computed tomography ((18)F-FDG PET/CT). This cross-sectional study included 63 participants with radiographic lesions suggesting old healed TB and with available (18)F-FDG PET/CT scans. The maximum standardized uptake value (SUVmax) measured in the lesions, the clinical characteristics, results of the tuberculin skin test (TST) and interferon-γ release assay (IGRA) were analyzed. The SUVmax in old healed TB was 1.5 or higher among nine (14.3%) participants. Age (adjusted odds ratio [aOR], 1.23; 95% CI, 1.03-1.46), history of previous TB (aOR, 60.43; 95% CI, 1.71-2131.65), and extent of the lesions (aOR, 1.34; 95% CI, 1.02-1.75) were associated with higher SUVmax. The positive rates for the TST and IGRA were not different between groups with and without increased FDG uptake. Increased FDG uptake on (18)F-FDG PET/CT was observed in a subset of patients with radiographic lesions suggesting old healed TB. Given that the factors associated with increased FDG uptake are known risk factors for TB development, the possibility exists that participants with old healed TB lesions with higher SUV on (18)F-FDG PET/CT scans might be at higher risk for active TB.

  19. Whole-body positron emission tomography using fluorodeoxyglucose for staging of lymphoma: effectiveness and comparison with computed tomography

    International Nuclear Information System (INIS)

    Stumpe, K.D.M.; Urbinelli, M.; Steinert, H.C.; Glanzmann, C.; Buck, A.; Schulthess, G.K. von

    1998-01-01

    The purpose of this study was to evaluate whole-body positron emission tomography (WB-PET) as a staging modality in Hodgkin's disease (HD) and non-Hodgkin lymphoma (NHL) and to compare it with computed tomography (CT) in a retrospective study. Seventy-one WB-PET studies using fluorodeoxyglucose (FDG) and 49 CT examinations were performed in 19 women and 31 men. Transaxial images were acquired and reformatted coronally and sagittally in PET. CT sections were obtained from the skull base to the pelvic floor. The written reports of the imaging data were compared with a reference standard constructed on the basis of all the data on the individual patients, including clinical follow-up of at least 6 months. The sensitivity and specificity of PET were, respectively, 86% and 96% for HD (n=53), and 89% and 100% for NHL (n=18). For CT sensitivity and specificity were 81% and 41% for HD (n=33) and 86% and 67% for NHL (n=16). Differences between PET and CT sensitivities were not significant, while in HD there was a significant difference in the specificity of PET and CT examinations, mainly because CT was unable to distinguish between active or recurrent disease and residual scar tissue after therapy. FDG tumour uptake was found in high- as well as low-grade NHL patients. In conclusion, PET appears to be highly sensitive and specific for staging of lymphoma. It is at least as sensitive as CT, and more specific, particularly in patients undergoing restaging, where a well-recognized diagnostic dilemma in CT is the presence of a post-therapeutic residual mass. (orig.)

  20. Cervical Lymph Node Metastases of Unknown Origin: Primary Tumor Detection with Whole-Body Positron Emission Tomography/Computed Tomography

    International Nuclear Information System (INIS)

    Nassenstein, K.; Veit-Haibach, P.; Stergar, H.; Gutzeit, A.; Freudenberg, L.; Kuehl, H.; Fischer, M.; Barkhausen, J.; Bockisch, A.; Antoch, G.

    2007-01-01

    Background: Identification of primary tumor in patients with cervical lymph node metastasis of unknown primary (MUO) has a great impact on therapy approach and potentially on patient prognosis. Purpose: To assess the diagnostic accuracy of combined positron emission tomography (PET)/computer tomography (CT) for primary tumor detection in cervical metastases of unknown origin compared to PET, CT, and PET+CT side-by-side evaluation. Material and Methods: 39 consecutive patients (eight women, 31 men; mean age 59.9±11.2 years) with MUO were enrolled in this study. PET/CT images were obtained 1 hour after injection of 350 MBq of fluorodeoxyglucose. Oral and intravenous contrast agents were administered in all patients to ensure diagnostic CT data. Fused PET/CT data were evaluated for primary tumor detection. Diagnostic accuracy was calculated and compared with CT alone, PET alone, and side-by-side PET+CT evaluation. Statistical analysis of differences in diagnostic performance between the different imaging procedures was based on the McNemar test. Results: Fused PET/CT depicted the primary tumor in 11 of 39 (28%) patients. In 28 (72%) patients, the primary tumor remained occult. CT revealed the primary in five (13%), PET alone in 10 (26%), and side-by-side evaluation of PET+CT in 10 (26%) of 39 patients. Statistical analysis showed no significant differences between the imaging modalities. Conclusion: PET, side-by-side PET+CT, and PET/CT revealed similar detection rates for primary tumors in cervical MUO patients. Therefore, cervical metastases of an unknown primary may be assessed with either of these imaging modalities. Detection rates with CT were substantially lower. Thus, inclusion of functional data for assessment of cervical MUO patients must be recommended

  1. A computed tomography-based spatial normalization for the analysis of [18F] fluorodeoxyglucose positron emission tomography of the brain.

    Science.gov (United States)

    Cho, Hanna; Kim, Jin Su; Choi, Jae Yong; Ryu, Young Hoon; Lyoo, Chul Hyoung

    2014-01-01

    We developed a new computed tomography (CT)-based spatial normalization method and CT template to demonstrate its usefulness in spatial normalization of positron emission tomography (PET) images with [(18)F] fluorodeoxyglucose (FDG) PET studies in healthy controls. Seventy healthy controls underwent brain CT scan (120 KeV, 180 mAs, and 3 mm of thickness) and [(18)F] FDG PET scans using a PET/CT scanner. T1-weighted magnetic resonance (MR) images were acquired for all subjects. By averaging skull-stripped and spatially-normalized MR and CT images, we created skull-stripped MR and CT templates for spatial normalization. The skull-stripped MR and CT images were spatially normalized to each structural template. PET images were spatially normalized by applying spatial transformation parameters to normalize skull-stripped MR and CT images. A conventional perfusion PET template was used for PET-based spatial normalization. Regional standardized uptake values (SUV) measured by overlaying the template volume of interest (VOI) were compared to those measured with FreeSurfer-generated VOI (FSVOI). All three spatial normalization methods underestimated regional SUV values by 0.3-20% compared to those measured with FSVOI. The CT-based method showed slightly greater underestimation bias. Regional SUV values derived from all three spatial normalization methods were correlated significantly (p normalization may be an alternative method for structure-based spatial normalization of [(18)F] FDG PET when MR imaging is unavailable. Therefore, it is useful for PET/CT studies with various radiotracers whose uptake is expected to be limited to specific brain regions or highly variable within study population.

  2. Feasibility of Computed Tomography-Guided Methods for Spatial Normalization of Dopamine Transporter Positron Emission Tomography Image.

    Science.gov (United States)

    Kim, Jin Su; Cho, Hanna; Choi, Jae Yong; Lee, Seung Ha; Ryu, Young Hoon; Lyoo, Chul Hyoung; Lee, Myung Sik

    2015-01-01

    Spatial normalization is a prerequisite step for analyzing positron emission tomography (PET) images both by using volume-of-interest (VOI) template and voxel-based analysis. Magnetic resonance (MR) or ligand-specific PET templates are currently used for spatial normalization of PET images. We used computed tomography (CT) images acquired with PET/CT scanner for the spatial normalization for [18F]-N-3-fluoropropyl-2-betacarboxymethoxy-3-beta-(4-iodophenyl) nortropane (FP-CIT) PET images and compared target-to-cerebellar standardized uptake value ratio (SUVR) values with those obtained from MR- or PET-guided spatial normalization method in healthy controls and patients with Parkinson's disease (PD). We included 71 healthy controls and 56 patients with PD who underwent [18F]-FP-CIT PET scans with a PET/CT scanner and T1-weighted MR scans. Spatial normalization of MR images was done with a conventional spatial normalization tool (cvMR) and with DARTEL toolbox (dtMR) in statistical parametric mapping software. The CT images were modified in two ways, skull-stripping (ssCT) and intensity transformation (itCT). We normalized PET images with cvMR-, dtMR-, ssCT-, itCT-, and PET-guided methods by using specific templates for each modality and measured striatal SUVR with a VOI template. The SUVR values measured with FreeSurfer-generated VOIs (FSVOI) overlaid on original PET images were also used as a gold standard for comparison. The SUVR values derived from all four structure-guided spatial normalization methods were highly correlated with those measured with FSVOI (P normalization methods provided reliable striatal SUVR values comparable to those obtained with MR-guided methods. CT-guided methods can be useful for analyzing dopamine transporter PET images when MR images are unavailable.

  3. Detection of thoracic aortic prosthetic graft infection with 18F-fluorodeoxyglucose positron emission tomography/computed tomography.

    Science.gov (United States)

    Tokuda, Yoshiyuki; Oshima, Hideki; Araki, Yoshimori; Narita, Yuji; Mutsuga, Masato; Kato, Katsuhiko; Usui, Akihiko

    2013-06-01

    To investigate the diagnostic value of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) in detecting thoracic aortic prosthetic graft infection. Nine patients with clinically suspected thoracic aortic graft infection underwent FDG-PET/CT scanning. In these patients, the diagnoses could not be confirmed using conventional modalities. The patients' clinical courses were retrospectively reviewed. On the basis of surgical, microbiological and clinical follow-up findings, the aortic grafts were considered infected in 4 patients and not infected in 5. All 4 patients with graft infection (root: 2 cases, arch: 1 case and descending: 1 case) eventually underwent in situ re-replacement. Two of the 4 patients also had abdominal grafts; however, only the thoracic grafts were replaced because uptake was low around the abdominal grafts. The maximal standardized uptake value (SUVmax) in the perigraft area was higher in the infected group than in the non-infected group (11.4 ± 4.5 vs 6.9 ± 6.4), although the difference was not statistically significant. According to the receiver operating characteristic analysis, SUVmax >8 appeared to be the cut-off value in distinguishing the two groups (sensitivity: 1.0 and specificity: 0.8). FDG-PET/CT is useful for confirming the presence of graft infection by detecting high uptake around grafts and excluding other causes of inflammation. An SUVmax value greater than 8 around a graft suggests the presence of graft infection. In addition, FDG-PET/CT can be used to clarify the precise extent of infection. This is especially useful if multiple separated prosthetic grafts have been implanted.

  4. Prognostic Value of SUVmax Measured by Fluorine-18 Fluorodeoxyglucose Positron Emission Tomography with Computed Tomography in Patients with Gallbladder Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jae Pil; Lim, Ilhan; Na, Im II; Cho, Eung Ho; Kim, Byung II; Choi, Chang Woon; Lim, Sang Moo [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2014-06-15

    The aim of this study is to investigate the prognostic value of F-18 fluorodeoxyglucose (F-18 FDG) positron emission tomography (PET)/computed tomography (CT) in gallbladder cancer patients. From June 2004 to June 2010, a total of 50 patients with gallbladder cancer who underwent diagnostic staging with F-18 FDG PET/CT following curative or palliative treatments were retrospectively evaluated. For the analysis, all patients were classified by age, sex, maximum standardized uptake value (SUVmax), lymph node (LN) or distant metastasis, serum level of CA19-9 and CEA, type of treatment and American Joint Committee on Cancer (AJCC) stage. The median survival for the 50 patients was 245 days and the median SUVmax in PET/CT was 8.3 (range, 0-19.7). Patients with SUVmax<6 survived significantly longer than patients with SUVmax≥6 (median 405 days vs 203 days, p = 0.0400). On Kaplan-Meier analysis, SUVmax (p =0.0400), stage (p =0.0001), CA19-9 (p =0.013), CEA (p =0.006), LN metastasis (p =0.0001), distant metastasis (p =0.0020), type of treatment (p =0.0001) were significantly associated with overall survival. Multivariate analysis study revealed that the patients with lower SUVmax measured from initial staging PET/CT (p =0.0380), no LN metastasis (p =0.0260), a lower stage (p =0.026) and curative treatment (p =0.0005) had longer survivals. The present study shows that SUVmax on F-18 FDG PET/CT can provide prognostic information in patients with gallbladder cancer.

  5. Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration for Staging of Patients with Non-Small Cell Lung Cancer without Mediastinal Involvement at Positron Emission Tomography-Computed Tomography

    DEFF Research Database (Denmark)

    Naur, Therese Maria Henriette; Konge, Lars; Clementsen, Paul Frost

    2017-01-01

    BACKGROUND: Staging of lung cancer is essential to the treatment, which is curative only in cases of localized disease. Previous studies have suggested that endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is unnecessary when positron emission tomography-computed tomog...

  6. The role of 18F-fluoro-2-deoxyglucose positron emission tomography/computed tomography in the management of patients with carcinoma of unknown primary.

    Science.gov (United States)

    Deonarine, P; Han, S; Poon, F W; de Wet, C

    2013-08-01

    Carcinoma of unknown primary is one of the ten most frequent cancers worldwide. Its median survival time is less than 10 months. Detecting primary tumour locations and/or occult metastatic lesions may inform definitive treatment and improve patients' prognosis. We aimed to determine: (1) the sensitivity, specificity and accuracy of (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography; (2) its detection rate of primary tumour locations and occult metastases and (3) factors associated with improved survival times. We retrospectively reviewed all cases in the West of Scotland for the period 1 December 2007 to 31 May 2011 that met all our selection criteria: (1) diagnosis of carcinoma of unknown primary; (2) a thorough but negative 'work-up' and (3) (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography report. Statistical methods included frequencies, Kaplan-Meier graphs and log-rank tests to compare survival times. (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography detected primary tumour sites in 19/51 (37.3%) and occult metastases in 28/51 (54.9%) of eligible patients. Its sensitivity, specificity and accuracy were 79.2%, 70.4% and 74.5%, respectively; 20/51 (39.2%) patients died during the study period with a median survival of 8.4 months (range 21.4, SD ± 6.2). The number of metastatic locations was strongly associated with survival (p = 0.002), but detection of a primary tumour site (p = 0.174) or histopathology (p = 0.301) was not. (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography detected occult metastatic sites in the majority and a primary cancer location in a substantial minority of patients. Our results were comparable with international literature and may indicate that (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography have an early role to improve the accuracy of cancer staging and to optimise carcinoma of unknown

  7. Impact of Single-Photon Emission Computed Tomography/Computed Tomography (SPECT/CT) and Positron Emission Tomography/Computed Tomography (PET/CT) in the Diagnosis of Traumatic Brain Injury (TBI): Case Report.

    Science.gov (United States)

    Molina-Vicenty, Irma L; Santiago-Sánchez, Michelaldemar; Vélez-Miró, Iván; Motta-Valencia, Keryl

    2016-09-01

    Traumatic brain injury (TBI) is defined as damage to the brain resulting from an external force. TBI, a global leading cause of death and disability, is associated with serious social, economic, and health problems. In cases of mild-to-moderate brain damage, conventional anatomical imaging modalities may or may not detect the cascade of metabolic changes that have occurred or are occurring at the intracellular level. Functional nuclear medicine imaging and neurophysiological parameters can be used to characterize brain damage, as the former provides direct visualization of brain function, even in the absence of overt behavioral manifestations or anatomical findings. We report the case of a 30-year-old Hispanic male veteran who, after 2 traumatic brain injury events, developed cognitive and neuropsychological problems with no clear etiology in the presence of negative computed tomography (CT) findings.

  8. Attenuation correction in pulmonary and myocardial single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Almquist, H

    2000-01-01

    The objective was to develop and validate methods for single photon emission computed tomography, SPECT, allowing quantitative physiologic and diagnostic studies of lung and heart. A method for correction of variable attenuation in SPECT, based on transmission measurements before administration of an isotope to the subject, was developed and evaluated. A protocol based upon geometrically well defined phantoms was developed. In a mosaic pattern phantom count rates were corrected from 39-43% to 101-110% of reference. In healthy subjects non-gravitational pulmonary perfusion gradients observed without attenuation correctionwere artefacts caused by attenuation. Pulmonary density in centre of right lung, obtained from the transmission measurement, was 0.28 {+-} 0.03 g/ml in normal subjects. Mean density was lower in large lungs compared to smaller ones. We also showed that regional ventilation/perfusion ratios could be measured with SPECT, using the readily available tracer {sup 133}Xe. Because of the low energy of {sup 133}Xe this relies heavily upon attenuation correction. A commercially available system for attenuation correction with simultaneous emission and transmission, considered to improve myocardial SPECT, performed erroneously. This could lead to clinical misjudgement. We considered that manufacturer-independent pre-clinical tests are required. In a test of two other commercial systems, based on different principles, an adapted variant of our initial protocol was proven useful. Only one of the systems provided correct emission count rates independently on phantom configuration. Errors in the other system were related to inadequate compensation of the influence of emission activity on the transmission study.

  9. Attenuation correction in pulmonary and myocardial single photon emission computed tomography

    International Nuclear Information System (INIS)

    Almquist, H.

    2000-01-01

    The objective was to develop and validate methods for single photon emission computed tomography, SPECT, allowing quantitative physiologic and diagnostic studies of lung and heart. A method for correction of variable attenuation in SPECT, based on transmission measurements before administration of an isotope to the subject, was developed and evaluated. A protocol based upon geometrically well defined phantoms was developed. In a mosaic pattern phantom count rates were corrected from 39-43% to 101-110% of reference. In healthy subjects non-gravitational pulmonary perfusion gradients observed without attenuation correction were artefacts caused by attenuation. Pulmonary density in centre of right lung, obtained from the transmission measurement, was 0.28 ± 0.03 g/ml in normal subjects. Mean density was lower in large lungs compared to smaller ones. We also showed that regional ventilation/perfusion ratios could be measured with SPECT, using the readily available tracer 133 Xe. Because of the low energy of 133 Xe this relies heavily upon attenuation correction. A commercially available system for attenuation correction with simultaneous emission and transmission, considered to improve myocardial SPECT, performed erroneously. This could lead to clinical misjudgement. We considered that manufacturer-independent pre-clinical tests are required. In a test of two other commercial systems, based on different principles, an adapted variant of our initial protocol was proven useful. Only one of the systems provided correct emission count rates independently on phantom configuration. Errors in the other system were related to inadequate compensation of the influence of emission activity on the transmission study

  10. 2-deoxy-2-(18F)fluoro-D-glucose positron emission tomography/computed tomography imaging in paediatric oncology

    Institute of Scientific and Technical Information of China (English)

    John; Freebody; Eva; A; Wegner; Monica; A; Rossleigh

    2014-01-01

    Positron emission tomography(PET) is a minimally in-vasive technique which has been well validated for the diagnosis, staging, monitoring of response to therapy, and disease surveillance of adult oncology patients. Tra-ditionally the value of PET and PET/computed tomogra-phy(CT) hybrid imaging has been less clearly defined for paediatric oncology. However recent evidence has emerged regarding the diagnostic utility of these mo-dalities, and they are becoming increasingly important tools in the evaluation and monitoring of children with known or suspected malignant disease. Important indi-cations for 2-deoxy-2-(18F)fluoro-D-glucose(FDG) PET in paediatric oncology include lymphoma, brain tumours, sarcoma, neuroblastoma, Langerhans cell histiocytosis, urogenital tumours and neurofibromatosis type Ⅰ. This article aims to review current evidence for the use of FDG PET and PET/CT in these indications. Attention will also be given to technical and logistical issues, the description of common imaging pitfalls, and dosimetric concerns as they relate to paediatric oncology.

  11. Safety of ventilation/perfusion single photon emission computed tomography for pulmonary embolism diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Le Roux, Pierre-Yves; Palard, Xavier; Robin, Philippe; Abgral, Ronan; Querellou, Solene; Salaun, Pierre-Yves [Universite Europeenne de Bretagne, Brest (France); Universite de Brest, Brest (France); CHRU de la Cavale Blanche, Service de medecine nucleaire, Brest (France); Delluc, Aurelien; Couturaud, Francis [Universite Europeenne de Bretagne, Brest (France); Universite de Brest, Brest (France); CHRU de la Cavale Blanche, Departement de medecine interne et de pneumologie, Brest (France); Le Gal, Gregoire [Universite Europeenne de Bretagne, Brest (France); University of Ottawa, Ottawa Hospital Research Institute, Ottawa (Canada); CHRU de la Cavale Blanche, Departement de medecine interne et de pneumologie, Brest (France); Universite de Brest, Brest (France)

    2014-10-15

    The aim of this management outcome study was to assess the safety of ventilation/perfusion single photon emission computed tomography (V/Q SPECT) for the diagnosis of pulmonary embolism (PE) using for interpretation the criteria proposed in the European Association of Nuclear Medicine (EANM) guidelines for V/Q scintigraphy. A total of 393 patients with clinically suspected PE referred to the Nuclear Medicine Department of Brest University Hospital from April 2011 to March 2013, with either a high clinical probability or a low or intermediate clinical probability but positive D-dimer, were retrospectively analysed. V/Q SPECT were interpreted by the attending nuclear medicine physician using a diagnostic cut-off of one segmental or two subsegmental mismatches. The final diagnostic conclusion was established by the physician responsible for patient care, based on clinical symptoms, laboratory test, V/Q SPECT and other imaging procedures performed. Patients in whom PE was deemed absent were not treated with anticoagulants and were followed up for 3 months. Of the 393 patients, the prevalence of PE was 28 %. V/Q SPECT was positive for PE in 110 patients (28 %) and negative in 283 patients (72 %). Of the 110 patients with a positive V/Q SPECT, 78 (71 %) had at least one additional imaging test (computed tomography pulmonary angiography or ultrasound) and the diagnosis of PE was eventually excluded in one patient. Of the 283 patients with a negative V/Q SPECT, 74 (26 %) patients had another test. The diagnosis of PE was finally retained in one patient and excluded in 282 patients. The 3-month thromboembolic risk in the patients not treated with anticoagulants was 1/262: 0.38 % (95 % confidence interval 0.07-2.13). A diagnostic management including V/Q SPECT interpreted with a diagnostic cut-off of ''one segmental or two subsegmental mismatches'' appears safe to exclude PE. (orig.)

  12. Safety of ventilation/perfusion single photon emission computed tomography for pulmonary embolism diagnosis

    International Nuclear Information System (INIS)

    Le Roux, Pierre-Yves; Palard, Xavier; Robin, Philippe; Abgral, Ronan; Querellou, Solene; Salaun, Pierre-Yves; Delluc, Aurelien; Couturaud, Francis; Le Gal, Gregoire

    2014-01-01

    The aim of this management outcome study was to assess the safety of ventilation/perfusion single photon emission computed tomography (V/Q SPECT) for the diagnosis of pulmonary embolism (PE) using for interpretation the criteria proposed in the European Association of Nuclear Medicine (EANM) guidelines for V/Q scintigraphy. A total of 393 patients with clinically suspected PE referred to the Nuclear Medicine Department of Brest University Hospital from April 2011 to March 2013, with either a high clinical probability or a low or intermediate clinical probability but positive D-dimer, were retrospectively analysed. V/Q SPECT were interpreted by the attending nuclear medicine physician using a diagnostic cut-off of one segmental or two subsegmental mismatches. The final diagnostic conclusion was established by the physician responsible for patient care, based on clinical symptoms, laboratory test, V/Q SPECT and other imaging procedures performed. Patients in whom PE was deemed absent were not treated with anticoagulants and were followed up for 3 months. Of the 393 patients, the prevalence of PE was 28 %. V/Q SPECT was positive for PE in 110 patients (28 %) and negative in 283 patients (72 %). Of the 110 patients with a positive V/Q SPECT, 78 (71 %) had at least one additional imaging test (computed tomography pulmonary angiography or ultrasound) and the diagnosis of PE was eventually excluded in one patient. Of the 283 patients with a negative V/Q SPECT, 74 (26 %) patients had another test. The diagnosis of PE was finally retained in one patient and excluded in 282 patients. The 3-month thromboembolic risk in the patients not treated with anticoagulants was 1/262: 0.38 % (95 % confidence interval 0.07-2.13). A diagnostic management including V/Q SPECT interpreted with a diagnostic cut-off of ''one segmental or two subsegmental mismatches'' appears safe to exclude PE. (orig.)

  13. Development of a simple photon emission computed tomography dedicated to the small animal

    International Nuclear Information System (INIS)

    Bekaert, V.

    2006-11-01

    The development of in vivo small animal imaging becomes essential to study human pathologies. The ImaBio project of Institut Pluridisciplinaire Hubert Curien (IPHC) fits in the process of developing new instruments for biomedical applications with the development of a multimodality imaging platform dedicated to small animal imaging (AMISSA). This thesis presents the study, the design and the development of a Single Photon Emission Computed Tomography (SPECT) which will be integrated to the AMISSA platform. The result of these developments is the possibility to obtain the spatial distribution of an injected molecule into the animal. The SPECT technical solutions are based on the acquired knowledge of the institute allowing the conception of a device with cameras adapted to the gamma detection produced by the radiotracers used in single photon imaging. In order to cover the entire of the transverse field of view, four gamma cameras are arranged in a ring around the volume of interest. Each camera consists of 5 individual modules based on a YAP:Ce crystal array, a multi-anode photomultiplier and a dedicated multichannel electronic device. Finally, 20 detection modules were calibrated to give the same result for an identical energy deposit. The data are acquired then process to extract the positions and the energies deposited by gamma photons in the crystals. This last information is then gathered to build the projections. The 3D reconstructed image from the projections is carried out by the sequence of two algorithms, analytical and iterative OS-EM, both modified to take into account the singular geometry of our detection system. Finally, the obtained image is fused with the anatomical information given by the micro Computed Tomography system. (author)

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  15. Multimodal imaging analysis of single-photon emission computed tomography and magnetic resonance tomography for improving diagnosis of Parkinson's disease

    International Nuclear Information System (INIS)

    Barthel, H.; Georgi, P.; Slomka, P.; Dannenberg, C.; Kahn, T.

    2000-01-01

    Parkinson's disease (PD) is characterized by a degeneration of nigrostriated dopaminergic neurons, which can be imaged with 123 I-labeled 2β-carbomethoxy-3β-(4-iodophenyl) tropane ([ 123 I]β-CIT) and single-photon emission computed tomography (SPECT). However, the quality of the region of interest (ROI) technique used for quantitative analysis of SPECT data is compromised by limited anatomical information in the images. We investigated whether the diagnosis of PD can be improved by combining the use of SPECT images with morphological image data from magnetic resonance imaging (MRI)/computed tomography (CT). We examined 27 patients (8 men, 19 women; aged 55±13 years) with PD (Hoehn and Yahr stage 2.1±0.8) by high-resolution [ 123 I]β-CIT SPECT (185-200 MBq, Ceraspect camera). SPECT images were analyzed both by a unimodal technique (ROIs defined directly within the SPECT studies) and a multimodal technique (ROIs defined within individual MRI/CT studies and transferred to the corresponding interactively coregistered SPECT studies). [ 123 I]β-CIT binding ratios (cerebellum as reference), which were obtained for heads of caudate nuclei (CA), putamina (PU), and global striatal structures were compared with clinical parameters. Differences between contra- and ipsilateral (related to symptom dominance) striatal [ 123 I]β-CIT binding ratios proved to be larger in the multimodal ROI technique than in the unimodal approach (e.g., for PU: 1.2*** vs. 0.7**). Binding ratios obtained by the unimodal ROI technique were significantly correlated with those of the multimodal technique (e.g., for CA: y=0.97x+2.8; r=0.70; P com subscore (r=-0.49* vs. -0.32). These results show that the impact of [ 123 I]β-CIT SPECT for diagnosing PD is affected by the method used to analyze the SPECT images. The described multimodal approach, which is based on coregistration of SPECT and morphological imaging data, leads to improved determination of the degree of this dopaminergic disorder

  16. Simultaneous 68Ga DOTATATE Positron Emission Tomography/Magnetic Resonance Imaging in Meningioma Target Contouring: Feasibility and Impact Upon Interobserver Variability Versus Positron Emission Tomography/Computed Tomography and Computed Tomography/Magnetic Resonance Imaging.

    Science.gov (United States)

    Maclean, J; Fersht, N; Sullivan, K; Kayani, I; Bomanji, J; Dickson, J; O'Meara, C; Short, S

    2017-07-01

    The increasing use of highly conformal radiation techniques to treat meningioma confers a greater need for accurate targeting. Several groups have shown that positron emission tomography/computed tomography (PET/CT) information alters meningioma targets contoured by single observers, but whether this translates into improved accuracy has not been defined. As magnetic resonance imaging (MRI) is the cornerstone of meningioma target contouring, simultaneous PET/MRI may be superior to PET/CT. We assessed whether 68 Ga DOTATATE PET imaging (from PET/CT and PET/MRI) reduced interobserver variability (IOV) in meningioma target volume contouring. Ten patients with meningioma underwent simultaneous 68 Ga DOTATATE PET/MRI followed by PET/CT. They were selected as it was anticipated that target volume definition in their cases would be particularly challenging. Three radiation oncologists contoured target volumes according to an agreed protocol: gross tumour volume (GTV) and clinical target volume (CTV) on CT/MRI alone, CT/MRI+PET(CT) and CT/MRI+PET(MRI). GTV/CTV Kouwenhoven conformity levels (KCL), regions of contour variation and qualitative differences between PET(CT) and PET(MRI) were evaluated. There was substantial IOV in contouring. GTV mean KCL: CT/MRI 0.34, CT/MRI+PET(CT) 0.38, CT/MRI+PET(MRI) 0.39 (P = 0.06). CTV mean KCL: CT/MRI 0.31, CT/MRI+PET(CT) 0.35, CT/MRI+PET(MRI) 0.35 (P = 0.04 for all groups; P > 0.05 for individual pairs). One observer consistently contoured largest and one smallest. Observers rarely decreased volumes in relation to PET. Most IOV occurred in bone followed by dural tail, postoperative bed and venous sinuses. Tumour edges were qualitatively clearer on PET(MRI) versus PET(CT), but this did not affect contouring. IOV in contouring challenging meningioma cases was large and only slightly improved with the addition of 68 Ga DOTATATE PET. Simultaneous PET/MRI for meningioma contouring is feasible, but did not improve IOV versus PET

  17. The use of combined single photon emission computed tomography and X-ray computed tomography to assess the fate of inhaled aerosol.

    Science.gov (United States)

    Fleming, John; Conway, Joy; Majoral, Caroline; Tossici-Bolt, Livia; Katz, Ira; Caillibotte, Georges; Perchet, Diane; Pichelin, Marine; Muellinger, Bernhard; Martonen, Ted; Kroneberg, Philipp; Apiou-Sbirlea, Gabriela

    2011-02-01

    Gamma camera imaging is widely used to assess pulmonary aerosol deposition. Conventional planar imaging provides limited information on its regional distribution. In this study, single photon emission computed tomography (SPECT) was used to describe deposition in three dimensions (3D) and combined with X-ray computed tomography (CT) to relate this to lung anatomy. Its performance was compared to planar imaging. Ten SPECT/CT studies were performed on five healthy subjects following carefully controlled inhalation of radioaerosol from a nebulizer, using a variety of inhalation regimes. The 3D spatial distribution was assessed using a central-to-peripheral ratio (C/P) normalized to lung volume and for the right lung was compared to planar C/P analysis. The deposition by airway generation was calculated for each lung and the conducting airways deposition fraction compared to 24-h clearance. The 3D normalized C/P ratio correlated more closely with 24-h clearance than the 2D ratio for the right lung [coefficient of variation (COV), 9% compared to 15% p computer analysis is a useful approach for applications requiring regional information on deposition.

  18. Statistical noise with the weighted backprojection method for single photon emission computed tomography

    International Nuclear Information System (INIS)

    Murayama, Hideo; Tanaka, Eiichi; Toyama, Hinako.

    1985-01-01

    The weighted backprojection (WBP) method and the radial post-correction (RPC) method were compared with other several attenuation correction methods for single photon emission computed tomography by computer simulation. These methods are the pre-correction method with arithmetic means of opposing projections, the post-correction method with a correction matrix, and the inverse attenuated Randon transform method. Statistical mean square noise in a reconstructed image was formulated, and was displayed two-dimensionally for typical simulated phantoms. The noise image for the WBP method was dependent on several parameters, namely, size of an attenuating object, distribution of activity, the attenuation coefficient, and choise of the reconstruction index, k and position of the reconstruction origin. The noise image for the WBP method with k=0 was almost the same for the RPC method. It has been shown that position of the reconstruction origin has to be chosen appropriately in order to improve the noise properties of the reconstructed image for the WBP method as well as the RPC method. Comparision of the different attenuation correction methods accomplished by using both the reconstructed images and the statistical noise images with the same mathematical phantom and convolving function concluded that the WBP method and the RPC method were more amenable to any radioisotope distributions than the other methods, and had the advantage of flexibility to improve image noise of any local positions. (author)

  19. Single photon emission computed tomography using a regularizing iterative method for attenuation correction

    International Nuclear Information System (INIS)

    Soussaline, Francoise; Cao, A.; Lecoq, G.

    1981-06-01

    An analytically exact solution to the attenuated tomographic operator is proposed. Such a technique called Regularizing Iterative Method (RIM) belongs to the iterative class of procedures where a priori knowledge can be introduced on the evaluation of the size and shape of the activity domain to be reconstructed, and on the exact attenuation distribution. The relaxation factor used is so named because it leads to fast convergence and provides noise filtering for a small number of iteractions. The effectiveness of such a method was tested in the Single Photon Emission Computed Tomography (SPECT) reconstruction problem, with the goal of precise correction for attenuation before quantitative study. Its implementation involves the use of a rotating scintillation camera based SPECT detector connected to a mini computer system. Mathematical simulations of cylindical uniformly attenuated phantoms indicate that in the range of a priori calculated relaxation factor a fast converging solution can always be found with a (contrast) accuracy of the order of 0.2 to 4% given that numerical errors and noise are or not, taken into account. The sensitivity of the (RIM) algorithm to errors in the size of the reconstructed object and in the value of the attenuation coefficient μ was studied, using the same simulation data. Extreme variations of +- 15% in these parameters will lead to errors of the order of +- 20% in the quantitative results. Physical phantoms representing a variety of geometrical situations were also studied

  20. Cardiac positron emission tomography

    International Nuclear Information System (INIS)

    Eftekhari, M.; Ejmalian, G.

    2003-01-01

    Positron emission tomography is an intrinsically tool that provide a unique and unparalleled approach for clinicians and researchers to interrogate the heart noninvasively. The ability to label substances of physiological interest with positron-emitting radioisotopes has permitted insight into normal blood flow and metabolism and the alterations that occur with disease states. Positron emission tomography of the heart has evolved as a unique, noninvasive approach for the assessment of myocardial perfusion, metabolism, and function. Because of the intrinsic quantitative nature of positron emission tomography measurements as well as the diverse compounds that can be labeled with positron- emitting radioisotopes, studies with positron emission tomography have provided rich insight into the physiology of the heart under diverse conditions

  1. Positron emission tomography

    International Nuclear Information System (INIS)

    Iio, Masahiro

    1982-01-01

    Utilization of positron emission tomography was reviewed in relation to construction and planned construction of small-size medical cyclotrons, planned construction of positron cameras and utilization of short-lived radionuclides. (Chiba, N.)

  2. Physical factors affecting single photon emission computed tomography (SPECT) applied in nuclear medicine

    International Nuclear Information System (INIS)

    Farag, H.I.; Khalil, W.A.; Hassan, R.A.

    2003-01-01

    many physical factors degrade single photon emission computed tomography (SPECT) images both qualitatively and quantitatively. Physical properties important for the assessment of the potential of emission computed tomography implemented by collimated detector systems include sensitivity, statistical and angular sampling requirements, attenuation compensation, resolution, uniformity, and multisection design constraints. SPECT has highlighted the used to improve gamma camera performance. Flood field nonuniformity is translated into tomographic the need to improve gamma camera performance. Flood field nonuniformity is translated into tomographic images as major artifacts because it distorts the data obtained at each projection. Also, poor energy resolution translates directly into degraded spatial resolution through reduced ability to reject scattered photons on the basic of pluses height analysis. The aim of this work is study the different and most important acquisition and processing parameters, which affect the quality of the SPECT images. The present study investigates the various parameters effecting SPECT images and experimental results demonstrate that: daily uniformity checks and evaluation are essential to ensure that the SPECT system is working properly. The Core used in the reconstruction process could be correct to avoid data misalignment. 60 mumblers of views gave the best image quality, rather than 20 or 30 views. Time per view (TPV) 30 or 20 sec gave a good image quality, rather than high-resolution collimator, is recommended in order to provide good spatial resolution. On the other hand patient motion could cause serious reconstruction artifacts. A cine display is recommended to identify movement artifacts. In the case of matrix size, matrix 128x128 give the best resolution than matrix 64x64. Energy window width, 15% compared with the standard 20% improved the resolution. Butter worth filter (cut off 0.57 cyc/cm with order 6 ) give the best resolution

  3. Positron emission tomography

    International Nuclear Information System (INIS)

    Dvorak, O.

    1989-01-01

    The principle is briefly described of positron emission tomography, and its benefits and constraints are listed. It is emphasized that positron emission tomography (PET) provides valuable information on metabolic changes in the organism that are otherwise only very difficult to obtain, such as brain diagnosis including relationships between mental disorders and the physiology and pathophysiology of the brain. A PET machine is to be installed in Czechoslovakia in the near future. (L.O.)

  4. Is a positron emission tomography-computed tomography scan useful in the staging of thymic epithelial neoplasms?

    Science.gov (United States)

    Viti, Andrea; Terzi, Alberto; Bianchi, Andrea; Bertolaccini, Luca

    2014-07-01

    A best evidence topic in thoracic surgery was written according to a structured protocol. The question addressed concerned the employment of 18-fluorine fluorodeoxyglucose positron emission tomography/computed tomography (PET-CT) in the preoperative evaluation of thymic epithelial neoplasms (TENs). We reviewed its role as a predictor of Masaoka stage and histology (according to the WHO). In clinical practice, stage is considered the most important determinant in the therapeutic approach. A total of 265 papers were found as a result of the reported search, of which 14 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. All the studies are retrospective analyses. Patient numbers varied from 13 to 58. Our research showed that PET-CT could clearly add information about the histology of the tumour. Thymic carcinoma constantly showed a higher standard uptake value (SUVmax) than thymomas. Furthermore, in one retrospective study of 36 patients, when using a derived PET indicator, the T/M ratio (ratio between SUVmax of the tumour and SUVmax of mediastinum, as conventionally measured at the level of the aortic arc), PET-CT could also differentiate between low- and high-risk thymomas (low risk vs high risk P = 0.01). In another study, a cut-off value of T/M ratio of 2.75 was identified between low- and high-risk TENs. The role of PET-CT in prediction of stage is harder to recognize. In one study, there was a statistically significant correlation between SUVmax, T/M ratio and Masaoka stage (P = 0.781 and 0.718, respectively). When analysing the data from the three larger series on this topic (58, 51 and 47 patients, the latter group selected in a multicentre study), only one study identified a correlation between SUVmax and Masaoka stage (Spearman correlation coefficient 0.30, P = 0.0436), while the other two failed

  5. Pretreatment Staging Positron Emission Tomography/Computed Tomography in Patients With Inflammatory Breast Cancer Influences Radiation Treatment Field Designs

    International Nuclear Information System (INIS)

    Walker, Gary V.; Niikura, Naoki; Yang Wei; Rohren, Eric; Valero, Vicente; Woodward, Wendy A.; Alvarez, Ricardo H.; Lucci, Anthony; Ueno, Naoto T.; Buchholz, Thomas A.

    2012-01-01

    Purpose: Positron emission tomography/computed tomography (PET/CT) is increasingly being utilized for staging of inflammatory breast cancer (IBC). The purpose of this study was to define how pretreatment PET/CT studies affected postmastectomy radiation treatment (PMRT) planning decisions for IBC. Methods and Materials: We performed a retrospective analysis of 62 patients diagnosed with IBC between 2004 and 2009, who were treated with PMRT in our institution and who had a staging PET/CT within 3 months of diagnosis. Patients received a baseline physical examination, staging mammography, ultrasonographic examination of breast and draining lymphatics, and chest radiography; most patients also had a bone scan (55 patients), liver imaging (52 patients), breast MRI (46 patients), and chest CT (25 patients). We compared how PET/CT findings affected PMRT, assuming that standard PMRT would target the chest wall, level III axilla, supraclavicular fossa, and internal mammary chain (IMC). Any modification of target volumes, field borders, or dose prescriptions was considered a change. Results: PET/CT detected new areas of disease in 27 of the 62 patients (44%). The areas of additional disease included the breast (1 patient), ipsilateral axilla (1 patient), ipsilateral supraclavicular (4 patients), ipsilateral infraclavicular (1 patient), ipsilateral IMC (5 patients), ipsilateral subpectoral (3 patients), mediastinal (8 patients), other distant/contralateral lymph nodes (15 patients), or bone (6 patients). One patient was found to have a non-breast second primary tumor. The findings of the PET/CT led to changes in PMRT in 11 of 62 patients (17.7%). These changes included additional fields in 5 patients, adjustment of fields in 2 patients, and higher doses to the supraclavicular fossa (2 patients) and IMC (5 patients). Conclusions: For patients with newly diagnosed IBC, pretreatment PET/CT provides important information concerning involvement of locoregional lymph nodes

  6. Ultrasound, elastography, and fluorodeoxyglucose positron emission tomography/computed tomography imaging in Riedel's thyroiditis: report of two cases.

    Science.gov (United States)

    Slman, Rouba; Monpeyssen, Hervé; Desarnaud, Serge; Haroche, Julien; Fediaevsky, Laurence Du Pasquier; Fabrice, Menegaux; Seret-Begue, Dominique; Amoura, Zahir; Aurengo, André; Leenhardt, Laurence

    2011-07-01

    Riedel's thyroiditis (RT) is a rare disease characterized by a chronic inflammatory lesion of the thyroid gland with invasion by a dense fibrosis. Publications of the imaging features of RT are scarce. To our knowledge, ultrasound elastography (USE) findings have not been previously reported. Therefore, we describe two patients with RT who were imaged with ultrasonography (US), USE, and fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT). Two women were referred for a large, hard goiter with compressive symptoms (dyspnea and dysphagia); in one patient, the goiter was associated with retroperitoneal fibrosis. In both cases, RT was confirmed by surgical biopsy with pathological examination. Thyroid US imaging was performed with a US scan and a 10-13 MHz linear transducer. The hardness of the tissues was analyzed using transient USE (ShearWave, Aixplorer-SuperSonic Imagine). PET/CT scanning was performed with a Philips Gemini GXL camera (GE Medical Systems). In the first patient, US examination revealed a compressive multinodular goiter with large solid hypoechoic and poorly vascularized areas adjacent to the nodules. The predominant right nodule was hypoechoic with irregular margins. The second patient had a hypoechoic goiter with large bilateral hypoechoic areas. In both cases, an unusual feature was observed: the presence of tissue surrounding the primitive carotid artery, associated with thrombi of the internal jugular vein. Further, USE showed heterogeneity in the stiffness values of the thyroid parenchyma varying between 21 kPa and 281 kPa. FDG-PET/CT imaging showed uptake foci in the thyroid gland. In both cases, US showed a decrease in the thyroid gland volume and the disappearance of encasement of the neck vasculature in response to corticosteroid treatment. In contrast, the FDG-PET/CT features remained unchanged. US features, such as vascular encasement and improvement under corticosteroid treatment, seem to be specific to this

  7. The early years of single photon emission computed tomography (SPECT): an anthology of selected reminiscences

    International Nuclear Information System (INIS)

    Jaszczak, Ronald Jack

    2006-01-01

    The origin of SPECT can be found in pioneering experiments on emission tomography performed approximately 50 years ago. This historical review consists of a compilation of first person recollections from nine trailblazing scientists who shaped the early years of SPECT instrumentation during the 1960s and 1970s. (review)

  8. The early years of single photon emission computed tomography (SPECT): an anthology of selected reminiscences

    Energy Technology Data Exchange (ETDEWEB)

    Jaszczak, Ronald Jack [Duke University Medical Center, Durham, NC 27710 (United States)

    2006-07-07

    The origin of SPECT can be found in pioneering experiments on emission tomography performed approximately 50 years ago. This historical review consists of a compilation of first person recollections from nine trailblazing scientists who shaped the early years of SPECT instrumentation during the 1960s and 1970s. (review)

  9. REVIEW: The early years of single photon emission computed tomography (SPECT): an anthology of selected reminiscences

    Science.gov (United States)

    Jaszczak, Ronald Jack

    2006-07-01

    The origin of SPECT can be found in pioneering experiments on emission tomography performed approximately 50 years ago. This historical review consists of a compilation of first person recollections from nine trailblazing scientists who shaped the early years of SPECT instrumentation during the 1960s and 1970s.

  10. The early years of single photon emission computed tomography (SPECT): an anthology of selected reminiscences.

    Science.gov (United States)

    Jaszczak, Ronald Jack

    2006-07-07

    The origin of SPECT can be found in pioneering experiments on emission tomography performed approximately 50 years ago. This historical review consists of a compilation of first person recollections from nine trailblazing scientists who shaped the early years of SPECT instrumentation during the 1960s and 1970s.

  11. Value of image fusion using single photon emission computed tomography with integrated low dose computed tomography in comparison with a retrospective voxel-based method in neuroendocrine tumours

    International Nuclear Information System (INIS)

    Amthauer, H.; Denecke, T.; Ruf, J.; Gutberlet, M.; Felix, R.; Lemke, A.J.; Rohlfing, T.; Boehmig, M.; Ploeckinger, U.

    2005-01-01

    The objective was the evaluation of single photon emission computed tomography (SPECT) with integrated low dose computed tomography (CT) in comparison with a retrospective fusion of SPECT and high-resolution CT and a side-by-side analysis for lesion localisation in patients with neuroendocrine tumours. Twenty-seven patients were examined by multidetector CT. Additionally, as part of somatostatin receptor scintigraphy (SRS), an integrated SPECT-CT was performed. SPECT and CT data were fused using software with a registration algorithm based on normalised mutual information. The reliability of the topographic assignment of lesions in SPECT-CT, retrospective fusion and side-by-side analysis was evaluated by two blinded readers. Two patients were not enrolled in the final analysis because of misregistrations in the retrospective fusion. Eighty-seven foci were included in the analysis. For the anatomical assignment of foci, SPECT-CT and retrospective fusion revealed overall accuracies of 91 and 94% (side-by-side analysis 86%). The correct identification of foci as lymph node manifestations (n=25) was more accurate by retrospective fusion (88%) than from SPECT-CT images (76%) or by side-by-side analysis (60%). Both modalities of image fusion appear to be well suited for the localisation of SRS foci and are superior to side-by-side analysis of non-fused images especially concerning lymph node manifestations. (orig.)

  12. Evaluation of left ventricular function and volume with multidetector-row computed tomography. Comparison with electrocardiogram-gated single photon emission computed tomography

    International Nuclear Information System (INIS)

    Suzuki, Takeya; Yamashina, Shohei; Nanjou, Shuji; Yamazaki, Junichi

    2007-01-01

    This study compared left ventricular systolic function and volume determined by multidetector-row computed tomography (MDCT) and electrocardiogram-gated single photon emission computed tomography (G-SPECT) Thirty-seven patients with coronary artery disease and non-cardiovascular disease underwent MDCT. In this study, left ventricular ejection fraction (EF), left ventricular end-diastolic volume (EDV) and left ventricular end-systolic volume (ESV) were calculated using only two-phase imaging with MDCT. Left ventricular function and volume were compared using measurements from G-SPECT. We conducted MDCT and G-SPECT virtually simultaneously. Both the EF and ESV evaluated by MDCT closely correlated with G-SPECT (r=0.763, P 65 bpm) during MDCT significantly influenced the difference in EF calculated from MDCT and G-SPECT (P<0.05). Left ventricular function can be measured with MDCT as well as G-SPECT. However, a heart rate over 65 bpm during MDCT negatively affects the EF correlation between MDCT and G-SPECT. (author)

  13. Influence of the Pixel Sizes of Reference Computed Tomography on Single-photon Emission Computed Tomography Image Reconstruction Using Conjugate-gradient Algorithm.

    Science.gov (United States)

    Okuda, Kyohei; Sakimoto, Shota; Fujii, Susumu; Ida, Tomonobu; Moriyama, Shigeru

    The frame-of-reference using computed-tomography (CT) coordinate system on single-photon emission computed tomography (SPECT) reconstruction is one of the advanced characteristics of the xSPECT reconstruction system. The aim of this study was to reveal the influence of the high-resolution frame-of-reference on the xSPECT reconstruction. 99m Tc line-source phantom and National Electrical Manufacturers Association (NEMA) image quality phantom were scanned using the SPECT/CT system. xSPECT reconstructions were performed with the reference CT images in different sizes of the display field-of-view (DFOV) and pixel. The pixel sizes of the reconstructed xSPECT images were close to 2.4 mm, which is acquired as originally projection data, even if the reference CT resolution was varied. The full width at half maximum (FWHM) of the line-source, absolute recovery coefficient, and background variability of image quality phantom were independent on the sizes of DFOV in the reference CT images. The results of this study revealed that the image quality of the reconstructed xSPECT images is not influenced by the resolution of frame-of-reference on SPECT reconstruction.

  14. Mathematics of Computed Tomography

    Science.gov (United States)

    Hawkins, William Grant

    A review of the applications of the Radon transform is presented, with emphasis on emission computed tomography and transmission computed tomography. The theory of the 2D and 3D Radon transforms, and the effects of attenuation for emission computed tomography are presented. The algebraic iterative methods, their importance and limitations are reviewed. Analytic solutions of the 2D problem the convolution and frequency filtering methods based on linear shift invariant theory, and the solution of the circular harmonic decomposition by integral transform theory--are reviewed. The relation between the invisible kernels, the inverse circular harmonic transform, and the consistency conditions are demonstrated. The discussion and review are extended to the 3D problem-convolution, frequency filtering, spherical harmonic transform solutions, and consistency conditions. The Cormack algorithm based on reconstruction with Zernike polynomials is reviewed. An analogous algorithm and set of reconstruction polynomials is developed for the spherical harmonic transform. The relations between the consistency conditions, boundary conditions and orthogonal basis functions for the 2D projection harmonics are delineated and extended to the 3D case. The equivalence of the inverse circular harmonic transform, the inverse Radon transform, and the inverse Cormack transform is presented. The use of the number of nodes of a projection harmonic as a filter is discussed. Numerical methods for the efficient implementation of angular harmonic algorithms based on orthogonal functions and stable recursion are presented. The derivation of a lower bound for the signal-to-noise ratio of the Cormack algorithm is derived.

  15. Gated single photon emission computer tomography for the detection of silent myocardial ischemia

    International Nuclear Information System (INIS)

    Pena Q, Yamile; Coca P, Marco Antonio; Batista C, Juan Felipe; Fernandez-Britto, Jose; Quesada P, Rodobaldo; Pena C; Andria

    2009-01-01

    Background: Asymptomatic patients with severe coronary atherosclerosis may have a normal resting electrocardiogram and stress test. Aim: To assess the yield of Gated Single Photon Emission Computer Tomography (SPECT) for the screening of silent myocardial ischemia in type 2 diabetic patients. Material and methods: Electrocardiogram, stress test and gated-SPECT were performed on 102 type 2 diabetic patients aged 60 ± 8 years without cardiovascular symptoms. All subjects were also subjected to a coronary angiography, whose results were used as gold standard. Results: Gated-SPECT showed myocardial ischemia on 26.5% of studied patients. The sensibility, specificity, accuracy, positive predictive value and negative predictive value were 92.3%, 96%, 95%, 88.8%, 97.3%, respectively. In four and six patients ischemia was detected on resting electrocardiogram and stress test, respectively. Eighty percent of patients with doubtful resting electrocardiogram results and 70% with a doubtful stress test had a silent myocardial ischemia detected by gated-SPECT. There was a good agreement between the results of gated-SPECT and coronary angiography (k =0.873). Conclusions: Gated-SPECT was an useful tool for the screening of silent myocardial ischemia

  16. Exercise-induced silent myocardial ischemia: Evaluation by thallium-201 emission computed tomography

    International Nuclear Information System (INIS)

    Kurata, C.; Sakata, K.; Taguchi, T.; Kobayashi, A.; Yamazaki, N.

    1990-01-01

    Factors associated with silent myocardial ischemia (SMI) during exercise testing were studied by means of thallium-201 emission computed tomography (ECT) in 471 patients. Coronary angiography was done in 290, of whom 167 were found to have significant coronary artery disease (CAD). Exercise-induced ischemia and its severity were defined with ECT. During exercise 108 (62%) of 173 patients with ischemia and 57 (50%) of 115 with ischemia and angiographically documented CAD had no chest pain. One third of the patients showed an inconsistency between scintigraphic ischemia and ischemia ST depression. Age, sex, prior myocardial infarction, and diabetes mellitus were not related to SMI. Patients with SMI had less severe ischemia despite a higher peak double product compared to those with painful ischemia. Among 91 with prior myocardial infarction and exercise-induced ischemia, 51 with periinfarction ischemia had a higher frequency of SMI than did 14 with ischemia remote from the prior infarct zone despite similarities in the severity of ischemia. In conclusion, factors localized within ischemic myocardium such as less severe ischemia or adjacency to a prior infarct made SMI more prevalent

  17. Single photon emission computed tomography in the diagnosis of Alzheimer`s disease

    Energy Technology Data Exchange (ETDEWEB)

    Hanyu, Haruo; Asano, Tetsuichi; Abe, Shin`e; Arai, Hisayuki; Iwamoto, Toshihiko; Takasaki, Masaru; Shindo, Hiroaki; Abe, Kimihiko [Tokyo Medical Coll. (Japan)

    1997-06-01

    Studies with single photon emission computed tomography (SPECT) have shown temporoparietal (TP) hypoperfusion in patients with Alzheimer`s disease (AD). We evaluated the utility of this findings in the diagnosis of AD. SPECT images with {sup 123}I-iodoamphetamine were analyzed qualitatively by a rater without knowledge of the subject`s clinical status. Sixty-seven of 302 consecutive patients were judged as having TP hypoperfusion by SPECT imaging. This perfusion pattern was observed in 44 of 51 patients with AD, in 5 with mixed dementia, 8 with cerebrovascular disease (including 5 with dementia), 4 with Parkinson`s disease (including 2 with dementia), 1 with normal pressure hydrocephalus, 1 with slowly progressive aphasia, 1 with progressive autonomic failure, 2 with age-associated memory impairment, and 1 with unclassified dementia. The sensitivity for AD was 86.3% (44 of 51 AD), and the specificity was 91.2% (229 of 251 non-AD). Next, we looked for differences in perfusion images between patients with AD and without AD. Some patients without AD had additional hypoperfusion beyond TP areas: deep gray matter hypoperfusion and diffuse frontal hypoperfusion, which could be used to differentiate them from the patients with AD. Others could not be distinguished from patients with AD by their perfusion pattern. Although patients with other cerebral disorders occasionally have TP hypoperfusion, this finding makes the diagnosis of AD very likely. (author)

  18. Evaluation of auto region of interest settings for single photon emission computed tomography findings

    International Nuclear Information System (INIS)

    Mizuno, Takashi; Takahashi, Masaaki; Yoshioka, Katsunori

    2008-01-01

    It has been noted that the manual settings of region of interest (ROI) to the single-photon-emission-computed-tomography (SPECT) slice lacked objectivity when the fixed quantity value of regional cerebral blood flow (rCBF) was measured previously. Therefore, we jointly developed software Brain ROI' with Daiichi Radioisotope Laboratories, Ltd. (Present name: FUJIFILM RI Pharma Co., Ltd.) The software normalized an individual brain to a standard brain template by using Statistical Parametric Mapping 2 (SPM 2) of the easy Z-score Imaging System ver. 3.0 (eZIS Ver. 3.0), and the ROI template was set to a specific slice. In this study, we evaluated the accuracy of this software with an ROI template that we made of useful size and shape, in some clinical samples. The method of automatic setting of ROI was the objective. However, we felt that we should use the shape of the ROI template without the influence of brain atrophy. Moreover, we should see normalization of the individual brain and confirm the accuracy of normalization. When normalization failed, we should partially correct the ROI or set everything by manual operation for the operator. However, it was thought that this software was useful if the tendency was understood because examples of failure were few. (author)

  19. Astigmatic single photon emission computed tomography imaging with a displaced center of rotation

    International Nuclear Information System (INIS)

    Wang, H.; Smith, M.F.; Stone, C.D.; Jaszczak, R.J.

    1998-01-01

    A filtered backprojection algorithm is developed for single photon emission computed tomography (SPECT) imaging with an astigmatic collimator having a displaced center of rotation. The astigmatic collimator has two perpendicular focal lines, one that is parallel to the axis of rotation of the gamma camera and one that is perpendicular to this axis. Using SPECT simulations of projection data from a hot rod phantom and point source arrays, it is found that a lack of incorporation of the mechanical shift in the reconstruction algorithm causes errors and artifacts in reconstructed SPECT images. The collimator and acquisition parameters in the astigmatic reconstruction formula, which include focal lengths, radius of rotation, and mechanical shifts, are often partly unknown and can be determined using the projections of a point source at various projection angles. The accurate determination of these parameters by a least squares fitting technique using projection data from numerically simulated SPECT acquisitions is studied. These studies show that the accuracy of parameter determination is improved as the distance between the point source and the axis of rotation of the gamma camera is increased. The focal length to the focal line perpendicular to the axis of rotation is determined more accurately than the focal length to the focal line parallel to this axis. copyright 1998 American Association of Physicists in Medicine

  20. Bone single photon emission computed tomography (SPECT in a patient with Pancoast tumor: a case report

    Directory of Open Access Journals (Sweden)

    Hamid Javadi

    Full Text Available CONTEXT: Non-small cell lung carcinomas (NSCLCs of the superior sulcus are considered to be the most challenging type of malignant thoracic disease. In this disease, neoplasms originating mostly from the extreme apex of the lung expand to the chest wall and thoracic inlet structures. Multiple imaging procedures have been applied to identify tumors and to stage and predict tumor resectability in surgical operations. Clinical examinations to localize pain complaints in shoulders and down the arms, and to screen for Horner's syndrome and abnormalities seen in paraclinical assessments, have been applied extensively for differential diagnosis of superior sulcus tumors. Although several types of imaging have been utilized for diagnosing and staging Pancoast tumors, there have been almost no reports on the efficiency of whole-body bone scans (WBBS for detecting the level of abnormality in cases of superior sulcus tumors. CASE REPORT: We describe a case of Pancoast tumor in which technetium-99m methylene diphosphonate (Tc-99m MDP bone single-photon emission-computed tomography (SPECT was able to accurately detect multiple areas of abnormality in the vertebrae and ribs. In describing this case, we stress the clinical and diagnostic points, in the hope of stimulating a higher degree of suspicion and thereby facilitating appropriate diagnosis and treatment. From the results of this study, further clinical trials to evaluate the potential of SPECT as an efficient imaging tool for the work-up on cases of Pancoast tumor are recommended.

  1. Quantification of myocardial infarct size by technetium-99m pyrophosphate single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Hiromichi; Fukuyama, Takaya; Aoki, Makoto; Inou, Tetsuji; Ashihara, Toshiaki; Nabeyama, Shyohzou; Yamamoto, Yuhsuke

    1989-04-01

    Myocardial infarct size in 41 patients with the first attack of acute transmural myocardial infarction (MI) was assessed by technetium-99m pyrophosphate single photon emission computed tomography (/sup 99m/TcPYP-SPECT). A ratio of the number of voxels of /sup 99m/TcPYP uptake into the infarct area to that into the thorax was calculated as a parameter of MI size. The ratio was positively correlated with both peak CPK activity (r=0.53, p<0.005, n=24) and extent score in /sup 201/Tl-SPECT (r=0.70, p<0.005, n=14) significantly in patients with anterior MI but not in patients with inferior MI. There was also significant negative correlation between the ratio and the left ventricular ejection fraction (LVEF) measured by RI angiography in both acute (r=-0.67, p<0.005, n=18) and chronic (r=-0.75, p<0.005, n=25) phases in patients with anterior MI. Recovery in LVEF at chronic phase was noted in patients with small anterior MI but not with large anterior MI. Eight of 14 patients with inferior MI had right ventricular MI, that might have affected evaluation of MI size and resulted in no correlation between variables. It was suggested that /sup 99m/TcPYP-SPECT was a useful method to evaluate MI size and to predict prognosis of cardiac function in patients with anterior MI but not in patients with inferior MI. (author).

  2. Verification of a hybrid adjoint methodology in Titan for single photon emission computed tomography - 316

    International Nuclear Information System (INIS)

    Royston, K.; Haghighat, A.; Yi, C.

    2010-01-01

    The hybrid deterministic transport code TITAN is being applied to a Single Photon Emission Computed Tomography (SPECT) simulation of a myocardial perfusion study. The TITAN code's hybrid methodology allows the use of a discrete ordinates solver in the phantom region and a characteristics method solver in the collimator region. Currently we seek to validate the adjoint methodology in TITAN for this application using a SPECT model that has been created in the MCNP5 Monte Carlo code. The TITAN methodology was examined based on the response of a single voxel detector placed in front of the heart with and without collimation. For the case without collimation, the TITAN response for single voxel-sized detector had a -9.96% difference relative to the MCNP5 response. To simulate collimation, the adjoint source was specified in directions located within the collimator acceptance angle. For a single collimator hole with a diameter matching the voxel dimension, a difference of -0.22% was observed. Comparisons to groupings of smaller collimator holes of two different sizes resulted in relative differences of 0.60% and 0.12%. The number of adjoint source directions within an acceptance angle was increased and showed no significant change in accuracy. Our results indicate that the hybrid adjoint methodology of TITAN yields accurate solutions greater than a factor of two faster than MCNP5. (authors)

  3. Brain blood flow studies with single photon emission computed tomography in patients with plateau waves

    International Nuclear Information System (INIS)

    Hayashi, Minoru; Kobayashi, Hidenori; Kawano, Hirokazu; Handa, Yuji; Noguchi, Yoshiyuki; Shirasaki, Naoki; Hirose, Satoshi

    1986-01-01

    The authors studied brain blood flow with single photon emission computed tomography (SPECT) in two patients with plateau waves. The intracranial pressure and blood pressure were also monitored continuously in these patients. They included one patient with brain-tumor (rt. sphenoid ridge meningioma) and another with hydrocephalus after subarachnoid hemorrhage due to rupture of lt. internal carotid aneurysm. The intracranial pressure was monitored through an indwelling ventricular catheter attached to a pressure transducer. The blood pressure was recorded through an intraarterial catheter placed in the dorsalis pedis artery. Brain blood flow was studied with Headtome SET-011 (manufactured by Shimazu Co., Ltd.). For this flow measurement study, an intravenous injection of Xenon-133 of about 30 mCi was given via an antecubital vein. The position of the slice for the SPECT was selected so as to obtain information not only from the cerebral hemisphere but also from the brain stem : a cross section 25 deg over the orbito-meatal line, passing through the inferior aspect of the frontal horn, the basal ganglia, the lower recessus of the third ventricle and the brain stem. The results indicated that, in the cerebral hemisphere, plateau waves were accompanied by a decrease in blood flow, whereas, in the brain stem, the blood flow showed little change during plateau waves as compared with the interval phase between two plateau waves. These observations may explain why there is no rise in the blood pressure and why patients are often alert during plateau waves. (author)

  4. Evaluation of myocardial involvement in muscular dystrophy with Thallium-201 emission computed tomography

    International Nuclear Information System (INIS)

    Yamamoto, S.; Kawai, N.; Matsushima, H.; Okada, M.; Yamauchi, K.; Yokota, M.; Hayashi, H.; Sotobata, I.; Sakuma, S.

    1985-01-01

    The clinical usefulness of quantitative analysis of thallium-201 emission computed tomography (ECT) for evaluation of left ventricular myocardial fibrosis was assessed on 45 patients with Duchenne(D), facioscapulohumeral(FSH), limbgirdle(LG) and myotonic(M) dystrophy. Trans-,long- and short-axial images were interpreted quantitatively using circumferential profile analysis, and the fibrotic tissue size (%FIB) was estimated by integration of hypoperfused areas in 6 to 8 consecutive short-axial slices. Lung/mediastinum count ratios (L/M ratio) were also assessed. Distinct ECT defects were found in 42 patients (all cases of D, FSH and LG, and 2 of 5 MTs). ECT defects were observed specifically in the posterolateral wall (71%) and apex (58%) in D, and were scattered in all LV walls in FSHG, LG and MT. ECG and VCG underestimated the extent of myocardial fibrosis in 17 patients (40%). Percent FIBs coincided with fibrotic tissue sizes proven by autopsy. Body-surface ECG should be influenced by cardiac position and rotation in the thorax, which were often observed in these disease entities. These factors were also assessed with ECT. The authors conclude; ECT to be useful for non-invasive evaluation of myocardial fibrosis in patients with various types of muscular dystrophy

  5. Hemodynamic evaluation of vascular reconstructive surgery for childhood moyamoya disease using single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Takikawa, Shugo; Kamiyama, Hiroyasu; Abe, Hiroshi [Hokkaido Univ., Sapporo (Japan). School of Medicine; Mitsumori, Kenji; Tsuru, Mitsuo

    1990-06-01

    To evaluate the efficacy of vascular reconstructive surgery for childhood moyamoya disease, the cerebral blood flow (CBF) in 31 hemispheres of 16 patients was examined by single photon emission computed tomography (SPECT) using the {sup 133}Xe inhalation method. Results were divided into two groups; 17 hemispheres with superficial temporal artery-middle cerebral artery (STA-MCA) anastomosis (A(+) group) and 14 hemispheres without anastomosis (A(-) group). The mean hemispheric CBF (mCBF) and regional CBF (rCBF) in the frontal, temporal, occipital, and basal ganglia regions were calculated. Pre- and postoperative SPECT on the 10 hemispheres of the A(+) group showed an increase in mCBF in 6 hemispheres, the disappearance of the low perfusion area (LPA) in all 5 hemispheres where LPA was present before surgery, and an improvement in rCBF distribution (an increase in rCBF in the frontal and temporal lobes and a decrease in the basal ganglia). This suggests that vascular reconstruction is greatly effective in treating this disease. A comparison between the A(+) group and the A(-) group by postoperative SPECT, as well as the clinical outcomes and the postoperative findings of electroencephalography and angiography, revealed that the A(+) group was superior to the A(-) group in the frequency of LPA (12% and 43%, respectively) and rCBF in the frontal region where STA-MCA anastomosis was usually performed. These results indicate that STA-MCA anastomosis with indirect synangiosis is the most effective treatment of childhood moyamoya disease. (author).

  6. Design of a serotonin 4 receptor radiotracer with decreased lipophilicity for single photon emission computed tomography.

    Science.gov (United States)

    Fresneau, Nathalie; Dumas, Noé; Tournier, Benjamin B; Fossey, Christine; Ballandonne, Céline; Lesnard, Aurélien; Millet, Philippe; Charnay, Yves; Cailly, Thomas; Bouillon, Jean-Philippe; Fabis, Frédéric

    2015-04-13

    With the aim to develop a suitable radiotracer for the brain imaging of the serotonin 4 receptor subtype (5-HT4R) using single photon emission computed tomography (SPECT), we synthesized and evaluated a library of di- and triazaphenanthridines with lipophilicity values which were in the range expected to favour brain penetration, and which demonstrated specific binding to the target of interest. Adding additional nitrogen atoms to previously described phenanthridine ligands exhibiting a high unspecific binding, we were able to design a radioiodinated compound [(125)I]14. This compound exhibited a binding affinity value of 0.094 nM toward human 5-HT4R and a high selectivity over other serotonin receptor subtypes (5-HTR). In vivo SPECT imaging studies and competition experiments demonstrated that the decreased lipophilicity (in comparison with our previously reported compounds 4 and 5) allowed a more specific labelling of the 5-HT4R brain-containing regions. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  7. Evaluation of myocardial involvement in muscular dystrophy with thallium-201 emission computed tomography

    International Nuclear Information System (INIS)

    Yamamoto, Shuhei; Sotobata, Iwao; Indo, Toshikatsu; Matsuoka, Yukihiko; Kawai, Naoki; Matsushima, Hideo; Suzuki, Akio; Abe, Tetsutaro; Sakuma, Sadayuki

    1986-01-01

    The clinical usefulness of thallium-201 myocardial perfusion scanning with emission computed tomography (ECT) for evaluation of left ventricular myocardial fibrosis was assessed on 47 patients with Duchenne (DMD), facioscapulohumeral (FSH), limb-girdle (LG) and myotonic (MT) dystrophy. Trans-, long- and short-axial images were interpreted quantitatively by circumferential profile analysis, and the fibrotic tissue size (%FIB) was estimated by integration of hypoperfused areas in 6 to 8 consecutive short-axial slices. Lung/mediastinum count ratios (L/M ratio), LV cavity dilatation, aneurysm formation and cardiac malrotations were also assessed with ECT. Distinct ECT perfusion defect was observed in 26 of 29 DMDs, and in 11 of 18 patients with other types. Perfusion defect was demonstrated in 95 of total 235 segments, and was observed specifically in the posterior wall (82 %) and the apex (65 %) in DMD, and was scattered in all LV wall segments in FSH, LG, and MT. Percent FIB correlated significantly with L/M ratio (r = 0.82, p < 0.01), and did not with age or clinical stage score. ECT showed marked LV dilatation in 7, apical aneurysm in 5 and cardiac malrotation in 23 of the 47 patients. In conclusion, ECT was considered to be a useful clinical means of evaluating myocardial involvement in patients with muscular dystrophy. (author)

  8. Single photon emission computed tomography (SPECT) in seizure disorders in childhood

    International Nuclear Information System (INIS)

    Vles, J.S.H.; Demandt, E.; Ceulemans, B.; de Roo, M.; Casaer, P.J.M.

    1990-01-01

    In 38 children with partial seizures, the EEG, CT and NMR findings were compared to the results obtained with Tc99m HMPAO single photon emission computed tomography (SPECT) in order to determine whether SPECT is a useful adjunct to EEG, CT and NMR in this age group. In 3 out of 7 patients with a normal EEG, SPECT showed focal abnormalities. Nine patients whose EEGs did not show adequate lateralization had an abnormal SPECT which revealed a focus. In 14 out of 21 patients with a normal CT, SPECT showed focal changes in 13 patients and diffuse changes in the other one. In 7 out of 12 patients with a normal NMR, SPECT showed focal abnormalities. Although clinical history and a careful description of the seizures are the most valuable information in partial seizure disorders, SPECT imaging gives valuable additional information, which might target treatment. SPECT was superior to CT and NMR with respect to the depiction of some kind of abnormality. (author)

  9. Regional cerebral blood flow analysis of vascular dementia by the single photon emission computed tomography

    International Nuclear Information System (INIS)

    Miyakawa, Kouichi; Watanabe, Sho; Suzuki, Michiyo; Kamijima, Gonbei

    1989-01-01

    In order to evaluate the relationship between the regional cerebral blood flow (CBF) and cerebrovascular dementia, eleven patients with vascular dementia and eight patients with non-demented infarction were studied and regional CBF were measured quantitatively with single photon emission computed tomography (SPECT) by using N-isopropyl-p-(I-123) iodoamphetamine. All cases were basal infarction and vascular dementia were diagnosed by less than 21.5 of the Hasegawa's dementia score and more than 7 of Hachinsk's ischemic score. The results of the present study were as follows: (1) Cerebrovascular dementia showed lower mean CBF value compared with non-demented group. (2) Regional CBF of bilateral frontal areas and affected basal ganglia were significantly reduced than occipital area in the dementia group. (3) A comparison of regional CBF and the Hasegawa's dementia score revealed a statistically significant correlation at the bilateral frontal areas in the dementia group. It is possible that measuring the regional CBF quantitatively by IMP-SPECT is useful for clinical analysis of vascular dementia. (author)

  10. Two-dimensional restoration of single photon emission computed tomography images using the Kalman filter

    International Nuclear Information System (INIS)

    Boulfelfel, D.; Rangayyan, R.M.; Kuduvalli, G.R.; Hahn, L.J.; Kloiber, R.

    1994-01-01

    The discrete filtered backprojection (DFBP) algorithm used for the reconstruction of single photon emission computed tomography (SPECT) images affects image quality because of the operations of filtering and discretization. The discretization of the filtered backprojection process can cause the modulation transfer function (MTF) of the SPECT imaging system to be anisotropic and nonstationary, especially near the edges of the camera's field of view. The use of shift-invariant restoration techniques fails to restore large images because these techniques do not account for such variations in the MTF. This study presents the application of a two-dimensional (2-D) shift-variant Kalman filter for post-reconstruction restoration of SPECT slices. This filter was applied to SPECT images of a hollow cylinder phantom; a resolution phantom; and a large, truncated cone phantom containing two types of cold spots, a sphere, and a triangular prism. The images were acquired on an ADAC GENESYS camera. A comparison was performed between results obtained by the Kalman filter and those obtained by shift-invariant filters. Quantitative analysis of the restored images performed through measurement of root mean squared errors shows a considerable reduction in error of Kalman-filtered images over images restored using shift-invariant methods

  11. Single photon emission computed tomography in the diagnosis of Alzheimer's disease

    International Nuclear Information System (INIS)

    Hanyu, Haruo; Asano, Tetsuichi; Abe, Shin'e; Arai, Hisayuki; Iwamoto, Toshihiko; Takasaki, Masaru; Shindo, Hiroaki; Abe, Kimihiko

    1997-01-01

    Studies with single photon emission computed tomography (SPECT) have shown temporoparietal (TP) hypoperfusion in patients with Alzheimer's disease (AD). We evaluated the utility of this findings in the diagnosis of AD. SPECT images with 123 I-iodoamphetamine were analyzed qualitatively by a rater without knowledge of the subject's clinical status. Sixty-seven of 302 consecutive patients were judged as having TP hypoperfusion by SPECT imaging. This perfusion pattern was observed in 44 of 51 patients with AD, in 5 with mixed dementia, 8 with cerebrovascular disease (including 5 with dementia), 4 with Parkinson's disease (including 2 with dementia), 1 with normal pressure hydrocephalus, 1 with slowly progressive aphasia, 1 with progressive autonomic failure, 2 with age-associated memory impairment, and 1 with unclassified dementia. The sensitivity for AD was 86.3% (44 of 51 AD), and the specificity was 91.2% (229 of 251 non-AD). Next, we looked for differences in perfusion images between patients with AD and without AD. Some patients without AD had additional hypoperfusion beyond TP areas: deep gray matter hypoperfusion and diffuse frontal hypoperfusion, which could be used to differentiate them from the patients with AD. Others could not be distinguished from patients with AD by their perfusion pattern. Although patients with other cerebral disorders occasionally have TP hypoperfusion, this finding makes the diagnosis of AD very likely. (author)

  12. Forensic applications of cerebral single photon emission computed tomography in mild traumatic brain injury.

    Science.gov (United States)

    Wortzel, Hal S; Filley, Christopher M; Anderson, C Alan; Oster, Timothy; Arciniegas, David B

    2008-01-01

    Traumatic brain injury (TBI) is a substantial source of mortality and morbidity world wide. Although most such injuries are relatively mild, accurate diagnosis and prognostication after mild TBI are challenging. These problems are complicated further when considered in medicolegal contexts, particularly civil litigation. Cerebral single photon emission computed tomography (SPECT) may contribute to the evaluation and treatment of persons with mild TBI. Cerebral SPECT is relatively sensitive to the metabolic changes produced by TBI. However, such changes are not specific to this condition, and their presence on cerebral SPECT imaging does not confirm a diagnosis of mild TBI. Conversely, the absence of abnormalities on cerebral SPECT imaging does not exclude a diagnosis of mild TBI, although such findings may be of prognostic value. The literature does not demonstrate consistent relationships between SPECT images and neuropsychological testing or neuropsychiatric symptoms. Using the rules of evidence shaped by Daubert v. Merrell Dow Pharmaceuticals, Inc., and its progeny to analyze the suitability of SPECT for forensic purposes, we suggest that expert testimony regarding SPECT findings should be admissible only as evidence to support clinical history, neuropsychological test results, and structural brain imaging findings and not as stand-alone diagnostic data.

  13. Evaluation of suspected malignant pulmonary lesions with 201Tl single photon emission computed tomography

    International Nuclear Information System (INIS)

    Tonami, N.; Yokoyama, K.; Shuke, N.

    1993-01-01

    201 Tl single photo emission computed tomography (SPECT) was evaluated in 170 patients suspected of having a malignant pulmonary lesion greater than 20 mm in diameter on the surgical specimen. Delayed SPECT visualized all of the 147 malignant pulmonary lesions and 16 of the 23 benign pulmonary lesions, and generally exhibited the lesion more clearly than the early SPECT images. There was no significant difference in delayed ratio (uptake ratio of the lesion to the normal lung on delayed scan) among the various histological groups except between the adenocarcinoma and large cell carcinoma groups, and no difference was noted between the malignant and benign lesions. However, in retention index (degree of retention in the lesion) a significant difference was noted between the malignant and benign lesions, although there was no significant difference in this index among malignant different histology groups. These results indicate that this method is useful for visualizing malignant pulmonary lesions greater than 20 mm in diameter to exclude the possibility of malignancy in the lesions when no abnormal 201 Tl accumulation is observed. When the lesion shows abnormal 201 Tl accumulation, the retention index seems to help differentiate malignant from benign lesions. (author)

  14. Quantitation of postexercise lung thallium-201 uptake during single photon emission computed tomography

    International Nuclear Information System (INIS)

    Kahn, J.K.; Carry, M.M.; McGhie, I.; Pippin, J.J.; Akers, M.S.; Corbett, J.R.

    1989-01-01

    To test the hypothesis that analysis of lung thallium uptake measured during single photon emission computed tomography (SPECT) yields supplementary clinical information as reported for planar imaging, quantitative analysis of lung thallium uptake following maximal exercise was performed in 40 clinically normal subjects (Group 1) and 15 angiographically normal subjects (Group 2). Lung thallium uptake was measured from anterior projection images using a ratio of heart-to-lung activities. Seventy subjects with coronary artery disease (CAD) (Group 3) determined by angiography (greater than or equal to 70% luminal stenosis) underwent thallium perfusion SPECT. Thirty-nine percent of these subjects had multivessel and 61% had single vessel CAD. Lung thallium uptake was elevated in 47 of 70 (67%) Group 3 subjects. Group 3 subjects with elevated lung thallium uptake did not differ from Group 3 subjects with normal lung thallium uptake with respect to extent or distribution of coronary artery disease, left ventricular function, or severity of myocardial ischemia as determined by exercise and redistribution thallium SPECT. Thus, the measurement of thallium lung uptake from anterior projection images obtained during SPECT frequently identifies patients with CAD, but it may not provide supplementary information regarding the extent of myocardial ischemia or ventricular dysfunction

  15. Time sequential single photon emission computed tomography studies in brain tumour using thallium-201

    International Nuclear Information System (INIS)

    Ueda, Takashi; Kaji, Yasuhiro; Wakisaka, Shinichiro; Watanabe, Katsushi; Hoshi, Hiroaki; Jinnouchi, Seishi; Futami, Shigemi

    1993-01-01

    Time sequential single photon emission computed tomography (SPECT) studies using thallium-201 were performed in 25 patients with brain tumours to evaluate the kinetics of thallium in the tumour and the biological malignancy grade preoperatively. After acquisition and reconstruction of SPECT data from 1 min post injection to 48 h (1, 2, 3, 4, 5, 6, 7, 8, 9, 10 and 15-20 min, followed by 4-6, 24 and 48 h), the thallium uptake ratio in the tumour versus the homologous contralateral area of the brain was calculated and compared with findings of X-ray CT, magnetic resonance imaging, cerebral angiography and histological investigations. Early uptake of thallium in tumours was related to tumour vascularity and the disruption of the blood-brain barrier. High and rapid uptake and slow reduction of thallium indicated a hypervascular malignant tumour; however, high and rapid uptake but rapid reduction of thallium indicated a hypervascular benign tumour, such as meningioma. Hypovascular and benign tumours tended to show low uptake and slow reduction of thallium. Long-lasting retention or uptake of thallium indicates tumour malignancy. (orig.)

  16. Imaging of lesions in the posterior cranial fossa using single photon emission computed tomography

    International Nuclear Information System (INIS)

    Kawakami, Michiro; Uesugi, Yasuo; Higashikawa, Masahiko; Ochi, Mari; Makimoto, Kazuo; Takahashi, Hiroaki; Shin, Akinori; Utsunomiya, Keita; Akagi, Hiroaki

    1988-01-01

    Lesions in the posterior cranial fossa were visualized by single photon emission computed tomography (SPECT) with 123 I-IMP (N-isopropyl-p- 123 I-iodoamphetamine) and 99m Tc-HM-PAO ( 99m Tc-hexametylpropyleneamine oxime). It is generally held that these radiopharmaceuticals penetrate the walls of cerebral blood vessels and that their accumulations in the brain tissue may reflect the cerebral blood flow. Six patients with lesions in the central nervous system all showed wider areas of abnormality in SPECT than in X-ray CT, indicating a larger lesion of blood flow disturbance. In the next series of 11 patients with vertigo or dizziness of unknown etiology, eight had abnormal findings in the scan with 123 I-IMP as did four of the nine in the scan with 99m Tc-HM-PAO. Thus, most patients with dizziness of unknown etiology may have some vertebral blood flow disorder, which in some cases is not clearly diagnosed by conventional vestibular examinations or even by X-ray CT scan. The accuracy of the diagnostic measures for otoneurological problems awaits further studies of their sensitivity and specificity. (author)

  17. Cardiac single-photon emission-computed tomography using combined cone-beam/fan-beam collimation

    International Nuclear Information System (INIS)

    Gullberg, Grant T.; Zeng, Gengsheng L.

    2004-01-01

    The objective of this work is to increase system sensitivity in cardiac single-photon emission-computed tomography (SPECT) studies without increasing patient imaging time. For imaging the heart, convergent collimation offers the potential of increased sensitivity over that of parallel-hole collimation. However, if a cone-beam collimated gamma camera is rotated in a planar orbit, the projection data obtained are not complete. Two cone-beam collimators and one fan-beam collimator are used with a three-detector SPECT system. The combined cone-beam/fan-beam collimation provides a complete set of data for image reconstruction. The imaging geometry is evaluated using data acquired from phantom and patient studies. For the Jaszazck cardiac torso phantom experiment, the combined cone-beam/fan-beam collimation provided 1.7 times greater sensitivity than standard parallel-hole collimation (low-energy high-resolution collimators). Also, phantom and patient comparison studies showed improved image quality. The combined cone-beam/fan-beam imaging geometry with appropriate weighting of the two data sets provides improved system sensitivity while measuring sufficient data for artifact free cardiac images

  18. Stress scintigraphy using single-photon emission computed tomography in the evaluation of coronary artery disease

    International Nuclear Information System (INIS)

    Nohara, R.; Kambara, H.; Suzuki, Y.; Tamaki, S.; Kadota, K.; Kawai, C.; Tamaki, N.; Torizuka, K.

    1984-01-01

    Twenty-seven patients with angina pectoris, 24 with postmyocardial infarction angina and 7 with normal coronary arteries were examined by exercise thallium-201 emission computed tomography (SPECT) and planar scintigraphy. Exercise SPECT was compared with the reperfusion imaging obtained approximately 2 to 3 hours after exercise. The sensitivity and specificity of demonstrating involved coronary arteries by identifying the locations of myocardial perfusion defects were 96 and 87% for right coronary artery, 88 and 89% for left anterior descending artery (LAD) and 78 and 100% for left circumflex artery (LC). These figures are higher than those for planar scintigraphy (85 and 87% for right coronary artery, 73 and 89% for LAD and 39 and 100% for LC arteries). In patients with 3-vessel disease, sensitivity of SPECT (100, 88 and 75% for right coronary artery, LAD and LC, respectively) was higher than planar imaging (88, 63 and 31%, respectively), with a significant difference for LC (p less than 0.05). In 1, 2 and 0-vessel disease the sensitivity and specificity of the 2 techniques were comparable. Multivessel disease was more easily identified as multiple coronary involvement than planar imaging with a significant difference in 3-vessel disease (p less than 0.05). In conclusion, stress SPECT provides useful information for the identification of LC lesions in coronary heart disease, including 3-vessel involvement

  19. Single photon emission computed tomography and albumin colloid imaging of the liver

    International Nuclear Information System (INIS)

    Croft, B.Y.; Teates, C.D.; Honeyman, J.C.

    1984-01-01

    A single photon emission computed tomography (ECT) system using the GE 400T Anger camera with 37 PM tubes and the SPETS software has been installed in our clinical laboratory. It has been used in the study of liver imaging with Tc-99m albumin colloid and other agents. The object of the study is to define what improvement in liver diagnosis might be made using ECT. Patients were injected with 3-4 mCi (ca 120 MBq) of colloid; five standard liver-spleen views and a 64-image ECT study were acquired. The ECT images were acquired either in a circle of the radius of the longer transverse axis of the patient or in an ellipse to match the patient contour. Studies were corrected for the attenuation of the Tc-99m gamma rays by tissue. A series of normal and abnormal patients have been studied and the data analyzed. The significant change in the technique of ECT imaging is the elliptical motion of the camera head which allows a better approximation of the patient contour and improves the spatial resolution of the images. (orig.)

  20. Quantification of leg muscle perfusion using thallium-201 single photon emission computed tomography

    International Nuclear Information System (INIS)

    Oshima, M.; Akanabe, H.; Sakuma, S.; Yano, T.; Nishikimi, N.; Shionoya, S.

    1989-01-01

    The purpose of this study is to quantify leg muscle perfusion with 201 Tl single photon emission computed tomography (SPECT). Six normal controls and 21 patients with peripheral arterial disease underwent this examination. Thallium-201 leg SPECT of both stress and redistribution was performed using a dual-headed digital gamma camera. Each slice of transverse images was normalized with pixels and whole-body counts. In normal controls, the activity of posterior tibial muscle components was significantly higher than that of anterior tibial muscle components (p less than 0.001). In 14 components, where patients had insignificant lesions, profile curves were normal in 10 (71%). In 62 components, where patients had arteriographically significant lesions, stress profile curves were abnormal in 57 (92%) compared with normal controls. Approximately, in half (28/62) components which had significant lesions, profile curves showed redistribution after 3 hr compared with normal redistribution curves. In three patients who underwent successful bypass graftings, the activity of each muscle component returned to a normal range

  1. Brain Single Photon Emission Computed Tomography in Anosmic Subjects Ater Closed Head Trauma

    Directory of Open Access Journals (Sweden)

    Roozbeh Banan

    2011-01-01

    Full Text Available Anosmia following head trauma is relatively common and in many cases is persistent and irreversible. The ability to objectively measure such a decline in smelling, for both clinical and medicolegal goals, is very important. The aim of this study was to find results of brain Single Photon Emission Computed Tomography (SPECT in anosmic subjects after closed head trauma. This case-control cross sectional study was conducted in a tertiary referral University Hospital. The brain perfusion state of nineteen anosmic patients and thirteen normal controls was evaluated by means of the SPECT with 99mtc- ECD infusion- before and after olfactory stimulation. The orbitofrontal lobe of the brain was assumed as the region of interest and changes in perfusion of this area before and after the stimulations were compared in two groups. The mean of brain perfusion in controls before and after the stimulation was 8.26% ± 0.19% and 9.89% ± 0.54%, respectively (P < 0.0001. Among patients group, these quantities were 7.97% ± 1.05% and 8.49% ± 1.5%, respectively (P < 0.004. The difference between all the measures in cases and controls were statistically significant (P < 0.0001. There were no differences in age and sex between two groups. The brain SPECT is an objective technique suitable for evaluating anosmia following the head trauma and it may be used with other diagnostic modalities

  2. Musicogenic epilepsy: review of the literature and case report with ictal single photon emission computed tomography.

    Science.gov (United States)

    Wieser, H G; Hungerbühler, H; Siegel, A M; Buck, A

    1997-02-01

    We report a case of musicogenic epilepsy with ictal single photon emission computed tomography (SPECT) study and discuss the findings of this patient in the context of 76 cases with musicogenic epilepsy described in the literature and seven other cases followed in Zurich. We analyzed the 83 patients according to the precipitating musical factors, type of epilepsy, presumed localization of seizure onset, and demographic data. Fourteen of 83 patients (17%) had seizures triggered exclusively by music. At time of examination, music was the only known precipitating stimulus in 65 of 83 patients (78%). Various characteristics of the musical stimulus were significant, e.g., musical category, familiarity, and instruments. Musicogenic epilepsy is a particular form of epilepsy with a strong correlation to the temporal lobe and a right-sided preponderance. A high musial standard might predispose for musicogenic epilepsy. Moreover, the majority of cases do not fall into the category of a strictly defined "reflex epilepsy," but appear to depend on the indermediary of a certain emotional reaction mediated through limbic mesial temporal lobe structures.

  3. Field-flood requirements for emission computed tomography with an Anger camer

    International Nuclear Information System (INIS)

    Rogers, W.L.; Clinthorne, N.H.; Harkness, B.A.; Koral, K.F.; Keyes, J.W. Jr.

    1982-01-01

    Emission computed tomography with a rotating camera places stringent requirements on camera uniformity and the stability of camera response. In terms of clinical tomographic imaging, we have studied the statistical accuracy required for camera flood correction, the requirements for flood accuracy, the utility and validity of flood and data image smoothing to reduce random noise effects, and the magnitude and effect of camera variations as a function of angular position, energy window, and tuning. Uniformity of the corrected flood response must be held to better than 1% to eliminate image artifacts that are apparent in a million-count image of a liver slice. This requires calibration with an accurate, well-mixed flood source. Both random fluctuations and variations in camera response with rotation must be kept below 1%. To meet the statistical limit, one requires at least 30 million counts for the flod-correction image. Smoothing the flood image alone introduces unacceptable image artifacts. Smoothing both the flood image and data, however, appears to be a good approach toward reducing noise effects. Careful camera tuning and magnetic shield design provide camera stability suitable for present clinical applications

  4. Pattern evoked cortical potential topography and positron emission computed tomography in cases with homonymous quadrantanopsia

    International Nuclear Information System (INIS)

    Kakisu, Yonetsugu; Adachi-Usami, Emiko; Kuroda, Noriko; Kawamura, Mitsuru; Yamazaki, Toshiro.

    1985-01-01

    Pattern evoked cortical potentials (PVECPs) and positron emission computed tomography (PET) were studied in two cases with lower homonymous quadrantanopsia caused by occlusion or hemorrhages of the artery of the optic radiation. Using 15 O 2 and C 15 O 2 as a tracer, PET was performed at rest under opened eye stimulation on 6 cm and 8 cm transverse section above the orbito-meatal line. On OM-6 level where the visual cortex of right and left hemisphere received the upper visual field information, symmetrical images of 15 O 2 and C 15 O 2 uptake were found. However, they were lateralized at the non-affected hemisphere in the images of OM-8 level, which corresponded to the anatomical lesion. The PVECP topogram recorded to the stimulation of the right and left lower quadrant visual field was studied by a 16 channel recording system. The positive maxima at the peak latency of P100 were found only at the non-affected hemisphere. It was, thus, proved that PVECP topogram and PET findings could demonstrate the functional abnormalities of the visual cortex in accordance with visual field defect measured by subjective perimetry. (author)

  5. What is Computed Tomography?

    Science.gov (United States)

    ... Imaging Medical X-ray Imaging What is Computed Tomography? Share Tweet Linkedin Pin it More sharing options ... Chest X ray Image back to top Computed Tomography (CT) Although also based on the variable absorption ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  7. Computed tomography

    International Nuclear Information System (INIS)

    Boyd, D.P.

    1989-01-01

    This paper reports on computed tomographic (CT) scanning which has improved computer-assisted imaging modalities for radiologic diagnosis. The advantage of this modality is its ability to image thin cross-sectional planes of the body, thus uncovering density information in three dimensions without tissue superposition problems. Because this enables vastly superior imaging of soft tissues in the brain and body, CT scanning was immediately successful and continues to grow in importance as improvements are made in speed, resolution, and cost efficiency. CT scanners are used for general purposes, and the more advanced machines are generally preferred in large hospitals, where volume and variety of usage justifies the cost. For imaging in the abdomen, a scanner with a rapid speed is preferred because peristalsis, involuntary motion of the diaphram, and even cardiac motion are present and can significantly degrade image quality. When contrast media is used in imaging to demonstrate scanner, immediate review of images, and multiformat hardcopy production. A second console is reserved for the radiologist to read images and perform the several types of image analysis that are available. Since CT images contain quantitative information in terms of density values and contours of organs, quantitation of volumes, areas, and masses is possible. This is accomplished with region-of- interest methods, which involve the electronic outlining of the selected region of the television display monitor with a trackball-controlled cursor. In addition, various image- processing options, such as edge enhancement (for viewing fine details of edges) or smoothing filters (for enhancing the detectability of low-contrast lesions) are useful tools

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  11. Post meningitis subdural hygroma: Anatomical and functional evaluation with (99m)Tc-ehylene cysteine dimer single photon emission tomography/computed tomography.

    Science.gov (United States)

    Sharma, Punit; Mishra, Ajiv; Arora, Geetanjali; Tripathi, Madhavi; Bal, Chandrasekhar; Kumar, Rakesh

    2013-01-01

    Subdural hygroma is the collection of cerebrospinal fluid in the subdural space. Most often these resolve spontaneously. However, in cases with neurological complications surgical drainage may be needed. We here, present the case of an 8-year-old boy with post meningitis subdural hygroma. (99m)Tc-ehylene cysteine dimer ((99m)Tc-ECD) hybrid single photon emission tomography/computed tomography (SPECT/CT) carried out in this patient, demonstrated the subdural hygroma as well as the associated cerebral hypoperfusion. If (99m)Tc-ECD SPECT/CT is integrated into management of these patients, it can help in decision making with respect to conservative versus surgical management.

  12. [(18) F]fluoromethylcholine (FCH) positron emission tomography/computed tomography (PET/CT) for lymph node staging of prostate cancer

    DEFF Research Database (Denmark)

    Poulsen, Mads H; Bouchelouche, Kirsten; Høilund-Carlsen, Poul F

    2012-01-01

    recurrence. Therefore, one may question whether surgical lymph node dissection (LND) is sufficiently reliable for staging of these patients. Several imaging methods for primary LN staging of patients with prostate cancer have been tested. Acceptable detection rates have not been achieved by CT or MRI...... this procedure. However, we did detect several bone metastases with [(18) F]FCH PET/CT that the normal bone scans had missed, and this might be worth pursuing. OBJECTIVES: •  To assess the value of [(18) F]fluoromethylcholine (FCH) positron emission tomography/computed tomography (PET/CT) for lymph node (LN...

  13. Primary neuroendocrine carcinoma of breast with liver and bone metastasis detected with fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Kamaleshwaran, Koramadai Karuppusamy; Mohanan, Vyshak; Shibu, Deepu; Radhakrishnan, Edathuruthy Kalarikal; Shinto, Ajit Sugunan

    2014-01-01

    Cases of primary neuroendocrine carcinoma (NEC) of the breast have been reported, though rare. We report the case of a 45-year-old woman presented with jaundice and evaluated to have liver metastasis from neuroendocrine origin. She underwent whole body positron emission tomography/computed tomography, which showed left breast lesion and bone metastasis. Fine-needle aspiration (FNA) of breast revealed a NEC. A diagnosis of a primary NEC of the breast was rendered with hepatic and bone metastasis. She was treated with peptide receptor radionuclide therapy and is on follow-up

  14. [18F]Fluorodeoxyglucose (FDG)-Positron Emission Tomography (PET)/Computed Tomography (CT) in Suspected Recurrent Breast Cancer

    DEFF Research Database (Denmark)

    Hildebrandt, Malene Grubbe; Gerke, Oke; Baun, Christina

    2016-01-01

    PURPOSE: To prospectively investigate the diagnostic accuracy of [(18)F]fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) with dual-time-point imaging, contrast-enhanced CT (ceCT), and bone scintigraphy (BS) in patients with suspected breast cancer recurrence....... PATIENTS AND METHODS: One hundred women with suspected recurrence of breast cancer underwent 1-hour and 3-hour FDG-PET/CT, ceCT, and BS within approximately 10 days. The study was powered to estimate the precision of the individual imaging tests. Images were visually interpreted using a four...

  15. A Unique Case of Diffuse Metastatic Neuroendocrine Cancer with Subcutaneous Nodules on 18F-Fluorodeoxyglucose Positron Emission Tomography/Computer Assisted Tomography

    International Nuclear Information System (INIS)

    Johnston, Mickaila J.; Sachedina, Archana; McDonald, James E.

    2015-01-01

    Neuroendocrine tumors (NETs) account for 8–10% of cases of carcinomas of unknown primary. Most of these cases are poorly differentiated with metastatic disease at the time of diagnosis. However, cutaneous metastatic presentation is rare. We present an interesting case of a 74-year-old woman presenting with cutaneous metastatic involvement from high grade poorly differentiated NET of unknown origin. She was referred to us with a diagnosis of lymphoma. 18 F-fluorodeoxyglucose positron emission tomography/computer assisted tomography imaging at our institution offered a differential diagnosis, including neuroendocrine cancer. Repeat skin lesion biopsy demonstrated “non-Merkel cell” carcinoma, favoring metastatic high-grade neuroendocrine carcinoma

  16. Malaria masquerading as relapse of Hodgkin's lymphoma on contrast enhanced 18F-fluorodeoxyglucose positron emission tomography/computed tomography: A diagnostic dilemma

    International Nuclear Information System (INIS)

    Jeph, Sunil; Thakur, Kamia; Shamim, Shamim Ahmed; Aggarwal, Ajay

    2014-01-01

    18 Flurodeoxyglucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) is nowadays routinely used in management of lymphoma patients. We here present a case of Hodgkin's lymphoma which showed 18 F-FDG avid splenomegaly on PET/CT done for clinically suspected relapse. Further evaluation by peripheral smear examination revealed malaria. The patient was then started on anti-malarial medications and follow-up PET/CT revealed resolution of hypermetabolic splenomegaly. This report highlights that in endemic regions malaria can cause 18 F-FDG avid splenomegaly and might mimic relapse of lymphoma

  17. A rare case of extensive skeletal muscle metastases in adenocarcinoma cervix identified by 18F-fluorodeoxyglucose positron emission tomography/computed tomography scan

    International Nuclear Information System (INIS)

    Vishnoi, Madan Gopal; Jain, Anurag; John, Arun Ravi; Paliwal, Dharmesh

    2016-01-01

    Adenocarcinoma cervix is an uncommon histological subtype of carcinoma cervix; further incidence of skeletal muscle metastases is even rarer. We report the identification of extensive fluorodeoxyglucose (FDG) avid metastatic skeletal muscle deposits in a known case of adenocarcinoma cervix. The largest lesion representative of muscle deposit in the right deltoid was histopathologically confirmed to be metastatic poorly differentiated carcinoma. This report also serves to highlight the importance of 18 F-FDG positron emission tomography/computed tomography (CT) as compared to conventional imaging modalities such as CT and ultrasonography and comments better over the description of invasiveness as well as the extent of disease in carcinoma cervix

  18. Skull base osteomyelitis in otitis externa: The utility of triphasic and single photon emission computed tomography/computed tomography bone scintigraphy

    International Nuclear Information System (INIS)

    Chakraborty, Dhritiman; Bhattacharya, Anish; Gupta, Ashok Kumar; Panda, Naresh Kumar; Das, Ashim; Mittal, Bhagwant Rai

    2013-01-01

    Skull base osteomyelitis (SBO) refers to infection that has spread beyond the external auditory canal to the base of the skull in advanced stages of otitis externa. Clinically, it may be difficult to differentiate SBO from severe otitis externa without bony involvement. This study was performed to determine the role of three phase bone scintigraphy (TPBS) and single photon emission tomography/computed tomography (SPECT/CT) in detecting SBO. We retrospectively analyzed records of 20 patients (14 M, 6 F) with otitis externa and suspected SBO. TPBS and SPECT/CT of the skull were performed. Findings were correlated with clinical, laboratory and diagnostic CT scan findings. All patients were diabetic with elevated erythrocyte sedimentation rate. A total of 18 patients had bilateral and two unilateral symptoms. Cranial nerves were involved in eight patients and microbiological culture of ear discharge fluid positive in seven. Early images showed increased temporal vascularity in nine patients and increased soft-tissue uptake in 10, while delayed images showed increased bone uptake in 19/20 patients. Localized abnormal tracer uptake was shown by SPECT/CT in the mastoid temporal (15), petrous (11), sphenoid (3) and zygomatic (1) and showed destructive changes in five. Thus, TPBS was found positive for SBO in 10/20 patients and changed the management in four. Our study suggests that TPBS with SPECT/CT is a useful non-invasive investigation for detection of SBO in otitis externa

  19. Diagnostic dilemma of degenerative joint disease, chronic avascular necrosis or metastasis in planar Tc-99m-methylene diphosphonate planar skeletal scintigraphy excluded by single positron emission computed tomography/computed tomography

    International Nuclear Information System (INIS)

    Jain, Tarun Kumar; Phulsunga, Rohit Kumar; Basher, Rajender Kumar; Kumar, Narendra; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2005-01-01

    We present a 71-year-old male patient subjected to skeletal scintigraphy for metastasis work up of prostate cancer. Whole body planar images revealed a solitary focal tracer uptake in left femoral head mimicking as solitary metastatic focus. Single positron emission computed tomography/computed tomography images localized this increased tracer uptake to the subchondral cysts with minimal sclerosis in left femur head with no decrease in size of femur head and was reported as (degenerative joint disease)

  20. Brain hypoperfusion on Tc-99m-ethylene dicysteine diethyl ester single-photon emission computed tomography in Hashimoto's encephalopathy

    OpenAIRE

    Grande, Mar?a Luz Dom?nguez; Constantino, Ana; Rayo, Juan Ignacio; Serrano, Justo; Infante, Jose Rafael; Garcia, Lucia; Duran, Carmen

    2013-01-01

    We present a 17-year-old female, previously diagnosed of autoimmune hyperthyroidism who had an acute neurological episode and presented high antithyroid antibodies titers, cerebral spinal fluid and electroencephalogram changes. Tc-99m ethylene dicysteine diethyl ester brain single-photon emission computed tomography (SPECT) showed global and patchy hypoperfusion. With glucocorticoid therapy, clinical symptoms disappeared; there was a decrease in antithyroid antibody levels and repeat brain SP...

  1. Brain hypoperfusion on Tc-99m-ethylene dicysteine diethyl ester single-photon emission computed tomography in Hashimoto's encephalopathy

    International Nuclear Information System (INIS)

    Grande, María Luz Domínguez; Rayo, Juan Ignacio; Serrano, Justo; Infante, Jose Rafael; Garcia, Lucia; Duran, Carmen; Constantino, Ana

    2013-01-01

    We present a 17-year-old female, previously diagnosed of autoimmune hyperthyroidism who had an acute neurological episode and presented high antithyroid antibodies titers, cerebral spinal fluid and electroencephalogram changes. 99m Tc ethylene dicysteine diethyl ester brain single-photon emission computed tomography (SPECT) showed global and patchy hypoperfusion. With glucocorticoid therapy, clinical symptoms disappeared; there was a decrease in antithyroid antibody levels and repeat brain SPECT revealed improvement of perfusion. (author)

  2. Evaluation of regional cerebral circulation and metabolism in moyamoya disease using positron emission computed tomography

    International Nuclear Information System (INIS)

    Kuwabara, Yasuo

    1986-01-01

    Regional cerebral blood flow, oxygen extraction fraction, metabolic rate of oxygen, blood volume and transit time were evaluated in 11 patients with moyamoya disease and 3 with suspected moyamoya disease using positron emission computed tomography. Eight of them were examined before and after EC-IC bypass surgery. Moyamoya patients were classified into four groups, namely, pediatric bilateral chronic type (over 5 years from onset), pediatric bilateral early type (within 5 years from onset), pediatric unilateral early type and adult type, according to age, duration of disease from onset and angiographic findings. These four groups showed different patterns on PET images; diffusely decreased CBF and CMRO2 in pediatric bilateral chronic type, decreased CBF and increased OEF in the frontal or temporoparietal region in pediatric bilateral early type, diffusely decreased CBF and increased OEF in the unilateral cerebral hemisphere in pediatric unilateral cerebral hemisphere in pediatric unilateral early type, and decreased CBF and CMRO2 in adult type. An increase of rCBV was demonstrated in frontal regions or basal ganglia in all groups, more prominently in pediatric patients. This was thought to be a common finding in moyamoya disease, corresponding to moyamoya vessels. Staging of moyamoya disease by PET was presented and compared to the angiographic staging. They were significantly correlated, and the stage 3 on PET image with decreased CMRO2 corresponded to the stage 3 or 4 on angiography, the most active stage of moyamoya disease. PET revealed increased CBF in the cortical area around EC-IC bypass but no remarkable changes in mean values of rCBF, OEF, CMRO2 and CBV in cerebral hemisphere. Some patients showed decreased rCBV in the basal ganglia. (J.P.N.)

  3. Dynamic single photon emission computed tomography-basic principles and cardiac applications

    International Nuclear Information System (INIS)

    Gullberg, Grant T; Reutter, Bryan W; Maltz, Jonathan S; Budinger, Thomas F; Sitek, Arkadiusz

    2010-01-01

    The very nature of nuclear medicine, the visual representation of injected radiopharmaceuticals, implies imaging of dynamic processes such as the uptake and wash-out of radiotracers from body organs. For years, nuclear medicine has been touted as the modality of choice for evaluating function in health and disease. This evaluation is greatly enhanced using single photon emission computed tomography (SPECT), which permits three-dimensional (3D) visualization of tracer distributions in the body. However, to fully realize the potential of the technique requires the imaging of in vivo dynamic processes of flow and metabolism. Tissue motion and deformation must also be addressed. Absolute quantification of these dynamic processes in the body has the potential to improve diagnosis. This paper presents a review of advancements toward the realization of the potential of dynamic SPECT imaging and a brief history of the development of the instrumentation. A major portion of the paper is devoted to the review of special data processing methods that have been developed for extracting kinetics from dynamic cardiac SPECT data acquired using rotating detector heads that move as radiopharmaceuticals exchange between biological compartments. Recent developments in multi-resolution spatiotemporal methods enable one to estimate kinetic parameters of compartment models of dynamic processes using data acquired from a single camera head with slow gantry rotation. The estimation of kinetic parameters directly from projection measurements improves bias and variance over the conventional method of first reconstructing 3D dynamic images, generating time-activity curves from selected regions of interest and then estimating the kinetic parameters from the generated time-activity curves. Although the potential applications of SPECT for imaging dynamic processes have not been fully realized in the clinic, it is hoped that this review illuminates the potential of SPECT for dynamic imaging

  4. Effectiveness of revascularization surgery evaluated by proton magnetic resonance spectroscopy and single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Uno, Masaaki; Ueda, Shin; Hondo, Hideki; Matsumoto, Keizo; Harada, Masafumi [Tokushima Univ. (Japan). School of Medicine

    1996-08-01

    Proton magnetic resonance spectroscopy (MRS) and single photon emission computed tomography (SPECT) were used to evaluate chronic ischemic regions in 26 stroke patients before and 1, 3, and 6 months after revascularization surgery. The volume of interest for proton MRS was placed in an area including part of the frontal and temporal opercula, insular cortex, and basal ganglia. Twenty healthy volunteers served as controls for proton MRS. Patients were divided into three groups according to the preoperative proton MRS. Group A (n=12) had significantly lower N-acetylaspartate/choline (NAA/Cho) and N-acetylaspartate/creatine (NAA/Cr) ratios on the operative side compared to those on the contralateral side, and also lower than those in normal subjects. In seven patients in Group A, postoperative serial proton MRS demonstrated no recovery of these ratios on the operative side. However, proton MRS of the other five patients indicated gradual improvement in these ratios on the operative side at 3 to 6 months after surgery, and SPECT indicated an increase in cerebral blood flow on the operative side in four of these five patients. In Group B (n=9), proton MRS and SPECT showed no laterality before revascularization and no remarkable change during the postoperative course. In Group C (n=5), NAA/Cho or NAA/Cr decreased on the contralateral side preoperatively. Two patients showed fluctuating values of NAA/Cho or NAA/Cr during the postoperative period. Serial proton MRS and SPECT Studies may be useful for the evaluation of revascularization surgery on ischemic regions. The efficacy of revascularization surgery on the metabolism may appear gradually within 3-6 months. (author)

  5. Myocardial involvement in muscular dystrophy evaluated by thallium-201 emission computed tomography

    International Nuclear Information System (INIS)

    Yamamoto, Shuhei; Matsushima, Hideo; Kawai, Naoki; Sotobata, Iwao

    1986-01-01

    The clinical usefulness of thallium-201 myocardial emission computed tomography (ECT) for evaluating left ventricular myocardial fibrosis was assessed in 47 patients with Duchenne (MD), facio-scapulo-humeral (FSH), limb-girdle (LG) and myotonic (MT) dystrophy. 1. Trans-, long- and short-axial images were interpreted quantitatively by circumferential profile analysis, and the extent of fibrotic tissue (%FIB) was estimated by integrating hypoperfused areas in six to eight consecutive short-axial slices. Lung/mediastinum count ratio (L/M ratio), LV cavity dilatation, aneurysm formation and cardiac malrotation were also assessed with ECT. 2. Distinct ECT defects were demonstrated in 95 of a total of 235 LV segments (40 %) and in 37 of 47 cases (85 % of DMD, 71 % of FSH, 50 % of MT and 60 % of LG). They were observed specifically in the posterior wall (82 %) and the apex (65 %) in DMD, and were scattered in all LV wall segments in FSH, LG, and MT. 3. There was a significant correlation between %FIB and the L/M ratio (r = 0.79, p < 0.001), and the L/M ratio was significantly higher in DMD than in MT (0.67 ± 0.36 vs 0.34 ± 0.25, p < 0.05). 4. ECT showed marked LV dilatation in seven (15 %), apical aneurysm in five (11 %) and vertical heart in 12 (26 %) of the 47 patients. 5. There were no significant correlations between age or clinical stage scores and numbers of defect segments or %FIB in each group. 6. During the one-year follow-up period of these patients, a DMD boy with the largest %FIB (54 %) and the highest L/M ratio (1.4) together with LV dilatation had complications of refractory heart failure and he died eight months following the ECT examination. 7. Thallium-201 planar imaging and standard 12-lead ECG underestimated the perfusion defects which were evaluated with ECT. (author)

  6. Single-photon emission computed tomography for the assessment of ventricular perfusion and function

    International Nuclear Information System (INIS)

    Gonzalez, Patricio; Dussaillant, Gaston; Gutierrez, Daniela; Berrocal, Isabel; Alay, Rita; Otarola, Sonia

    2013-01-01

    Background: Single-photon emission computed tomography (SPECT) can be used as a non-invasive tool for the assessment of coronary perfusion. Aim: To assess ventricular perfusion and function by SPECT in patients with single vessel coronary artery disease. Material and Methods: Among patients with indications for a coronary artery angiography, those with significant lesions in one vessel, were selected for the study. Within 24 hours, cardiac SPECT examinations on basal conditions and after high doses of dipyridamole, were performed. SPECT data from 38 patients with a low probability of coronary artery disease was used for comparisons. Results:Ten patients aged 61 ± 8 years (seven men) were studied. Visual analysis of SPECT revealed signs suggestive of ischemia in eight patients. The remaining two patients did not have perfusion disturbances. SPECT detected eight of ten abnormal vessels reported in the coronary artery angiography. There were two false negative results Summed stress, summed rest and summed difference scores were 9.78 ± 6.51, 3.22 ± 5.07 and 6.33 ± 4.97, respectively. The ejection fractions under stress and at rest were 53 ± 11.7% and 61 ± 15.7% respectively (p ≤ 0.01). The figures for the control group were 69.1 ± 13.5% and 75.2 ± 12.04% respectively (significantly different from patients). Two patients had a summed motion score above 14.9. Likewise, two patients had a summed thickening score above 10.9. Conclusions: SPECT detected 80% of coronary lesions found during coronary artery angiography. Visual analysis of perfusion is highly reliable for diagnosis. Quantitative parameters must be considered only as reference parameters

  7. Reverse redistribution in dipyridamole-loading thallium-201 images using single photon emission computed tomography

    International Nuclear Information System (INIS)

    Mori, Kiyoo; Masuda, Masanosuke; Bunko, Hisashi.

    1986-01-01

    Dipyridamole was infused intravenously at a rate of 0.142 mg/kg per min for four min, and a stress image was obtained 10 min after the injection of two mCi 201 Tl. The myocardial image of Tl was analyzed by single photon emission computed tomography and its washout rate was calculated by the segmental ROI method. Myocardial function and the motion of the left ventricular wall were analyzed by 99m Tc-RBC-gated cardiac pool imaging. Reverse redistribution was noted in 27 (21.6 %) of 125 consecutive Tl dipyridamole and redistribution myocardial imaging studies. The stress image demonstrated normal perfusion (group 1) and reduced perfusion (group 2) of Tl. Group 1 consisted of 17 patients with diabetes mellitus, supraventricular arrhythmias, hypertension, and others. Group 2 consisted of 10 patients with subendocardial infarction, diabetes mellitus, and hypertension, and others. The percentage prevalence of reverse redistribution among patients with supraventricular arrhythmia was 62.5 % (five of eight patients), with subendocardial infarction 60.0 % (three of five), with hypertension 42.8 % (six of 14), and with diabetes mellitus 40.0 % (eight of 20), while in those with transmyocardial infarction and angina pectoris no reverse redistribution percentage was found. The washout rate of Tl in normal perfusion areas was 44.0 ± 12.8 %, the reverse redistribution of group 1 was 47.4 ± 12.8 %, and of group 2 was 51.2 ± 8.2 %. The washout rate of the reverse redistribution of group 2 was significantly greater than that of the normal areas. In gated cardiac pool imaging, patients in group 2 had significantly larger areas showing abnormal contraction of the left ventricular wall and significantly lower ejection fraction than did group 1. In the electrocardiogram ST segment depression was noted more frequently in group 2 than group 1. No Q wave was present in the corresponding reverse redistribution area. (J.P.N.)

  8. Dynamic single photon emission computed tomography-basic principles and cardiac applications

    Energy Technology Data Exchange (ETDEWEB)

    Gullberg, Grant T; Reutter, Bryan W; Maltz, Jonathan S; Budinger, Thomas F [E O Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Sitek, Arkadiusz, E-mail: gtgullberg@lbl.go [Brigham and Women' s Hospital and Harvard Medical School, Boston, MA (United States)

    2010-10-21

    The very nature of nuclear medicine, the visual representation of injected radiopharmaceuticals, implies imaging of dynamic processes such as the uptake and wash-out of radiotracers from body organs. For years, nuclear medicine has been touted as the modality of choice for evaluating function in health and disease. This evaluation is greatly enhanced using single photon emission computed tomography (SPECT), which permits three-dimensional (3D) visualization of tracer distributions in the body. However, to fully realize the potential of the technique requires the imaging of in vivo dynamic processes of flow and metabolism. Tissue motion and deformation must also be addressed. Absolute quantification of these dynamic processes in the body has the potential to improve diagnosis. This paper presents a review of advancements toward the realization of the potential of dynamic SPECT imaging and a brief history of the development of the instrumentation. A major portion of the paper is devoted to the review of special data processing methods that have been developed for extracting kinetics from dynamic cardiac SPECT data acquired using rotating detector heads that move as radiopharmaceuticals exchange between biological compartments. Recent developments in multi-resolution spatiotemporal methods enable one to estimate kinetic parameters of compartment models of dynamic processes using data acquired from a single camera head with slow gantry rotation. The estimation of kinetic parameters directly from projection measurements improves bias and variance over the conventional method of first reconstructing 3D dynamic images, generating time-activity curves from selected regions of interest and then estimating the kinetic parameters from the generated time-activity curves. Although the potential applications of SPECT for imaging dynamic processes have not been fully realized in the clinic, it is hoped that this review illuminates the potential of SPECT for dynamic imaging

  9. Prognostic implications of atrial fibrillation in patients undergoing myocardial perfusion single-photon emission computed tomography.

    Science.gov (United States)

    Abidov, Aiden; Hachamovitch, Rory; Rozanski, Alan; Hayes, Sean W; Santos, Marcia M; Sciammarella, Maria G; Cohen, Ishac; Gerlach, James; Friedman, John D; Germano, Guido; Berman, Daniel S

    2004-09-01

    The aim of this research was to determine whether presence of atrial fibrillation (AF) provides incremental prognostic information relative to myocardial perfusion single-photon emission computed tomography (MPS) with respect to risk of cardiac death (CD). The prognostic significance of AF in patients undergoing MPS is not known. A total of 16,048 consecutive patients undergoing MPS were followed-up for a mean of 2.21 +/- 1.15 years for the development of CD. Of those, 384 patients (2.4%) had AF. Cox proportional hazards method was used to compare clinical and perfusion data for the prediction of CD in patients with and without AF. Atrial fibrillation was a significant predictor of CD in patients with normal (1.6% per year vs. 0.4% per year in non-AF patients), mildly abnormal (6.3% per year vs. 1.2% per year), and severely abnormal MPS (6.4% per year vs. 3.7% per year) (p < 0.001 for all). By multivariable analysis, AF patients had worse survival (p = 0.001) even after adjustment for the variables most predictive of CD: age, diabetes, shortness of breath, use of vasodilator stress, rest heart rate, and the nuclear variables. In the 4,239 patients with left ventricular ejection fraction evaluated by gated MPS, AF demonstrated incremental prognostic value not only over clinical and nuclear variables, but also over left ventricular ejection in predicting CD (p = 0.014). The presence of AF independently increases the risk of cardiac events over perfusion and function variables in patients undergoing MPS. Patients with AF have a high risk of CD, even when MPS is only mildly abnormal. Whether patients with AF and mildly abnormal MPS constitute a group more deserving of early referral to cardiac catheterization is a question warranting further study.

  10. Regional cerebral blood flow in status epileptics measured by single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Ichiseki, Hajime; Terashi, Akiro; Hamamoto, Makoto; Miyazaki, Tokuzo.

    1995-01-01

    We have performed single photon emission computed tomography (SPECT) with 99m Tc-hexamethylpropylene amineoxime (HM-PAO) to evaluate regional cerebral blood flow (rCBF) in status epileptics (SE) caused by a cerebral vascular accident. In addition, we have discussed the neurophysiology of SE based on the SPECT findings. A total of sixteen patients (5 males and 11 females, average age; 78.2 years old) with SE who were suffering from prolonged consciousness disturbance were investigated. When SPECT was performed in the ictal state, there was a remarkable increase in radio isotope (RI) uptake at the focus which correlated well with EEG findings. However, in other cortical regions, basal ganglia and thalamus, there was a relatively demonstrated decrease in RI uptake compared with that of the focus. Additionally in the interictal state, we found a decrease in RI uptake in the epileptic foci and normal recovery of the RI uptake level in other cerebral regions. We speculate that these characteristic patterns of cerebral blood flow distribution shown by SPECT scans in the ictal state reflect the state of consciousness disturbance due to SE. In general, in the elderly, it is difficult to make a differential diagnosis between prolonged consciousness disturbance due to nonconvulsive SE and other diseases such as cardiovascular diseases, dehydration, metabolic disorder, etc. Nevertheless, nonconvulsive SE causes diffuse cell loss and irreversible brain damage. Therefore the elderly who have suffered from prolonged consciousness disturbance due to SE need an exact diagnosis and immediate medical treatment. When we diagnose a nonconvulsive SE, the characteristic findings of SPECT scans in the ictal state are very clear and useful. In conclusion, SPECT is a very simple and non-invasive method that demonstrates abnormalities of brain function exactly. Therefore, we should perform not only EEC but also SPECT scans when making a diagnosis of SE. (author)

  11. Regional cerebral blood flow in status epileptics measured by single photon emission computed tomography (SPECT)

    Energy Technology Data Exchange (ETDEWEB)

    Ichiseki, Hajime; Terashi, Akiro [Nippon Medical School, Tokyo (Japan); Hamamoto, Makoto; Miyazaki, Tokuzo

    1995-12-01

    We have performed single photon emission computed tomography (SPECT) with {sup 99m}Tc-hexamethylpropylene amineoxime (HM-PAO) to evaluate regional cerebral blood flow (rCBF) in status epileptics (SE) caused by a cerebral vascular accident. In addition, we have discussed the neurophysiology of SE based on the SPECT findings. A total of sixteen patients (5 males and 11 females, average age; 78.2 years old) with SE who were suffering from prolonged consciousness disturbance were investigated. When SPECT was performed in the ictal state, there was a remarkable increase in radio isotope (RI) uptake at the focus which correlated well with EEG findings. However, in other cortical regions, basal ganglia and thalamus, there was a relatively demonstrated decrease in RI uptake compared with that of the focus. Additionally in the interictal state, we found a decrease in RI uptake in the epileptic foci and normal recovery of the RI uptake level in other cerebral regions. We speculate that these characteristic patterns of cerebral blood flow distribution shown by SPECT scans in the ictal state reflect the state of consciousness disturbance due to SE. In general, in the elderly, it is difficult to make a differential diagnosis between prolonged consciousness disturbance due to nonconvulsive SE and other diseases such as cardiovascular diseases, dehydration, metabolic disorder, etc. Nevertheless, nonconvulsive SE causes diffuse cell loss and irreversible brain damage. Therefore the elderly who have suffered from prolonged consciousness disturbance due to SE need an exact diagnosis and immediate medical treatment. When we diagnose a nonconvulsive SE, the characteristic findings of SPECT scans in the ictal state are very clear and useful. In conclusion, SPECT is a very simple and non-invasive method that demonstrates abnormalities of brain function exactly. Therefore, we should perform not only EEC but also SPECT scans when making a diagnosis of SE. (author).

  12. Emission computed tomography using rotating gamma cameras for stress 201Tl myocardial imaging

    International Nuclear Information System (INIS)

    Takeda, Kan; Maeda, Hisato; Nakagawa, Tsuyoshi; Yamaguchi, Nobuo; Taguchi, Mitsuo

    1983-01-01

    The purpose of this study is to evaluate the efficacy of emission computed tomography (ECT) for stress 201 Tl myocardial imaging to localize coronary artery disease (CAD) in comparison with planar (PL) images. In a series of 14 normal subjects and 53 patients with CAD proved coronary arteriography, ECT and PL imaging were performed successively. ECT data were collected for 90 projections in a 64 x 64 matrix form with a total aquisition time of 6 munutes over 180 0 of opposed dual cameras ratation and tomographic sections oriented perpendicular and parallel to the long axis of left ventricle were reconstructed. PL images were obtained for left lateral, left anterior oblique (30 0 and 45 0 ) and anterior projections. Both ECT and PL myocardial images were divided into 8 segments and segmental analysis was performed by visual interpretation. The ECT images remarkably increased sensitivity over the PL images in left anterior descending (LAD) artery (from 56% to 76%), right coronary artery (RCA) (from 50% to 96%), and circumflex artery (CX) (from 56% to 69%) lesions. The specificity for ECT images, as compared with PL images, was higher in LAD (88% against 85%) but slightly lower in RCA (70% ag ainst 72%) and CX (84% against 88%). Overall accuracy, therefore, was improved in LAD (from 67% to 81%) and RCA (from 64% to 79%) but equal in CX (81%). We conclude that stress 201 Tl ECT imaging result in a remarkable improvement in the localization of CAD, especially in patients with RCA lesions and multi-vessel disease. (author)

  13. Usefulness of isoproterenol stress thallium-201 myocardial single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Watanabe, Shigeyuki; Ajisaka, Ryuichi; Masuoka, Takeshi

    1990-01-01

    Twenty patients complaining of chest pain were referred for isoproterenol stress thallium-201 myocardial single photon emission computed tomography (ISO-SPECT). The findings were compared with those obtained from isoproterenol stress ECG testing (ISO-ECG) and exercise SPECT (EX-SPECT). Isoproterenol was iv injected in a dose of 0.02 μg/kg/min. The amount was continuously increased until limited by chest pain, ST depression, and/or determined heart rate criteria. The patients were scanned immediately and three hours after giving isoproterenol. Transient hypoperfusion was regarded as myocardial ischemia. Washout rate, obtained from circumferential profile analysis on the short axis SPECT images, was expressed by Bull's eye display. Fifteen patients with angiographically significant stenosis of 75% or greater were diagnosed as having coronary artery disease (CAD). The other five patients had normal coronary artery (NC). In diagnosing CAD, ISO-ECG and ISO-SPECT had a sensitivity of 80% and 92%, respectively. Because the NC group had negative findings for redistribution on ISO-SPECT, the specificy of ISO-SPECT seemed to be high. For multi-vessel disease, redistribution on ISO-SPECT tended to underestimate coronary lesions. The underestimation was, however, corrected by calculating washout rate. For evaluable 11 patients undergoing concurrent EX-SPECT, ISP-SPECT was equivalent or superior to EX-SPECT in diagnostic sensitivity. None of the patients had severe side effects of isoproterenol, except for some having arrhythmia. The results indicated that ISO-SPECT is a safe, high sensitive diagnostic approach that is comparable to Ex-SPECT. (N.K.)

  14. Novel application of quantitative single-photon emission computed-tomography/computed tomography to predict early response to methimazole in Graves' disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Joo; Bang, Ji In; Kim, Ji Young; Moon, Jae Hoon [Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam (Korea, Republic of); So, Young [Dept. of Nuclear Medicine, Konkuk University Medical Center, Seoul (Korea, Republic of); Lee, Won Woo [Institute of Radiation Medicine, Medical Research Center, Seoul National University, Seoul (Korea, Republic of)

    2017-06-15

    Since Graves' disease (GD) is resistant to antithyroid drugs (ATDs), an accurate quantitative thyroid function measurement is required for the prediction of early responses to ATD. Quantitative parameters derived from the novel technology, single-photon emission computed tomography/computed tomography (SPECT/CT), were investigated for the prediction of achievement of euthyroidism after methimazole (MMI) treatment in GD. A total of 36 GD patients (10 males, 26 females; mean age, 45.3 ± 13.8 years) were enrolled for this study, from April 2015 to January 2016. They underwent quantitative thyroid SPECT/CT 20 minutes post-injection of {sup 99m}Tc-pertechnetate (5 mCi). Association between the time to biochemical euthyroidism after MMI treatment and uptake, standardized uptake value (SUV), functional thyroid mass (SUVmean × thyroid volume) from the SPECT/CT, and clinical/biochemical variables, were investigated. GD patients had a significantly greater %uptake (6.9 ± 6.4%) than historical control euthyroid patients (n = 20, 0.8 ± 0.5%, p < 0.001) from the same quantitative SPECT/CT protocol. Euthyroidism was achieved in 14 patients at 156 ± 62 days post-MMI treatment, but 22 patients had still not achieved euthyroidism by the last follow-up time-point (208 ± 80 days). In the univariate Cox regression analysis, the initial MMI dose (p = 0.014), %uptake (p = 0.015), and functional thyroid mass (p = 0.016) were significant predictors of euthyroidism in response to MMI treatment. However, only uptake remained significant in a multivariate Cox regression analysis (p = 0.034). A uptake cutoff of 5.0% dichotomized the faster responding versus the slower responding GD patients (p = 0.006). A novel parameter of thyroid uptake from quantitative SPECT/CT is a predictive indicator of an early response to MMI in GD patients.

  15. The Added Value of a Single-photon Emission Computed Tomography-Computed Tomography in Sentinel Lymph Node Mapping in Patients with Breast Cancer and Malignant Melanoma.

    Science.gov (United States)

    Bennie, George; Vorster, Mariza; Buscombe, John; Sathekge, Mike

    2015-01-01

    Single-photon emission computed tomography-computed tomography (SPECT-CT) allows for physiological and anatomical co-registration in sentinel lymph node (SLN) mapping and offers additional benefits over conventional planar imaging. However, the clinical relevance when considering added costs and radiation burden of these reported benefits remains somewhat uncertain. This study aimed to evaluate the possible added value of SPECT-CT and intra-operative gamma-probe use over planar imaging alone in the South African setting. 80 patients with breast cancer or malignant melanoma underwent both planar and SPECT-CT imaging for SLN mapping. We assessed and compared the number of nodes detected on each study, false positive and negative findings, changes in surgical approach and or patient management. In all cases where a sentinel node was identified, SPECT-CT was more accurate anatomically. There was a significant change in surgical approach in 30 cases - breast cancer (n = 13; P 0.001) and malignant melanoma (n = 17; P 0.0002). In 4 cases a node not identified on planar imaging was seen on SPECT-CT. In 16 cases additional echelon nodes were identified. False positives were excluded by SPECT-CT in 12 cases. The addition of SPECT-CT and use of intra-operative gamma-probe to planar imaging offers important benefits in patients who present with breast cancer and melanoma. These benefits include increased nodal detection, elimination of false positives and negatives and improved anatomical localization that ultimately aids and expedites surgical management. This has been demonstrated in the context of industrialized country previously and has now also been confirmed in the setting of a emerging-market nation.

  16. The Added Value of a Single-photon Emission Computed Tomography-Computed Tomography in Sentinel Lymph Node Mapping in Patients with Breast Cancer and Malignant Melanoma

    International Nuclear Information System (INIS)

    Bennie, George; Vorster, Mariza; Buscombe, John; Sathekge, Mike

    2015-01-01

    Single-photon emission computed tomography-computed tomography (SPECT-CT) allows for physiological and anatomical co-registration in sentinel lymph node (SLN) mapping and offers additional benefits over conventional planar imaging. However, the clinical relevance when considering added costs and radiation burden of these reported benefits remains somewhat uncertain. This study aimed to evaluate the possible added value of SPECT-CT and intra-operative gamma-probe use over planar imaging alone in the South African setting. 80 patients with breast cancer or malignant melanoma underwent both planar and SPECT-CT imaging for SLN mapping. We assessed and compared the number of nodes detected on each study, false positive and negative findings, changes in surgical approach and or patient management. In all cases where a sentinel node was identified, SPECT-CT was more accurate anatomically. There was a significant change in surgical approach in 30 cases - breast cancer (n = 13; P 0.001) and malignant melanoma (n = 17; P 0.0002). In 4 cases a node not identified on planar imaging was seen on SPECT-CT. In 16 cases additional echelon nodes were identified. False positives were excluded by SPECT-CT in 12 cases. The addition of SPECT-CT and use of intra-operative gamma-probe to planar imaging offers important benefits in patients who present with breast cancer and melanoma. These benefits include increased nodal detection, elimination of false positives and negatives and improved anatomical localization that ultimately aids and expedites surgical management. This has been demonstrated in the context of industrialized country previously and has now also been confirmed in the setting of a emerging-market nation

  17. Comparison of Single-Photon Emission Computed Tomography-Computed Tomography (SPECT/CT) and Conventional Planar Lymphoscintigraphy for Sentinel Node Localization in Patients with Cutaneous Malignancies.

    Science.gov (United States)

    Doepker, Matthew P; Yamamoto, Maki; Applebaum, Matthew A; Patel, Nupur U; Jaime Montilla-Soler, M; Sarnaik, Amod A; Wayne Cruse, C; Sondak, Vernon K; Zager, Jonathan S

    2017-02-01

    Accurate preoperative lymphoscintigraphy is vital to performing sentinel lymph node biopsy (SLNB) for cutaneous malignancies. Potential advantages of single-photon emission computed tomography with integrated computed tomography (SPECT/CT) include the ability to readily identify aberrant drainage patterns as well as provide the surgeon with three-dimensional anatomic landmarks not seen on conventional planar lymphoscintigraphy (PLS). Patients with cutaneous malignancies who underwent SLNB with preoperative imaging using both SPECT/CT and PLS from 2011 to 2014 were identified. Both SPECT/CT and PLS were obtained in 351 patients (median age, 69 years; range, 5-94 years) with cutaneous malignancies (melanoma = 300, Merkel cell carcinoma = 33, squamous cell carcinoma = 8, other = 10) after intradermal injection of 99m technetium sulfur colloid (median dose 300 µCi). A mean of 4.3 hot spots were identified on SPECT/CT compared to 3.0 on PLS (p CT and PLS, while 172 (49 %) had additional hot spots identified on SPECT/CT compared to only 24 (6.8 %) additional on PLS. SPECT/CT demonstrated additional nodal basins in 103 patients (29.4 %), compared to only 11 patients (3.1 %) with additional basins on PLS. SPECT/CT is a useful adjunct that can help with sentinel node localization in challenging cases. It identified additional hot spots not seen on PLS in almost 50 % of patients. Because PLS identified hot spots not seen on SPECT/CT in 6.8 % of patients, we recommend using both modalities jointly. Long-term follow-up will be required to validate the clinical significance of the additional hot spots identified by SPECT/CT.

  18. Prediction of sentinel lymph node status using single-photon emission computed tomography (SPECT)/computed tomography (CT) imaging of breast cancer.

    Science.gov (United States)

    Tomiguchi, Mai; Yamamoto-Ibusuki, Mutsuko; Yamamoto, Yutaka; Fujisue, Mamiko; Shiraishi, Shinya; Inao, Touko; Murakami, Kei-ichi; Honda, Yumi; Yamashita, Yasuyuki; Iyama, Ken-ichi; Iwase, Hirotaka

    2016-02-01

    Single-photon emission computed tomography (SPECT)/computed tomography (CT) improves the anatomical identification of sentinel lymph nodes (SNs). We aimed to evaluate the possibility of predicting the SN status using SPECT/CT. SN mapping using a SPECT/CT system was performed in 381 cases of clinically node-negative, operable invasive breast cancer. We evaluated and compared the values of SN mapping on SPECT/CT, the findings of other modalities and clinicopathological factors in predicting the SN status. Patients with SNs located in the Level I area were evaluated. Of the 355 lesions (94.8 %) assessed, six cases (1.6 %) were not detected using any imaging method. According to the final histological diagnosis, 298 lesions (78.2 %) were node negative and 83 lesions (21.7 %) were node positive. The univariate analysis showed that SN status was significantly correlated with the number of SNs detected on SPECT/CT in the Level I area (P = 0.0048), total number of SNs detected on SPECT/CT (P = 0.011), findings of planar lymphoscintigraphy (P = 0.011) and findings of a handheld gamma probe during surgery (P = 0.012). According to the multivariate analysis, the detection of multiple SNs on SPECT/CT imaging helped to predict SN metastasis. The number of SNs located in the Level I area detected using the SPECT/CT system may be a predictive factor for SN metastasis.

  19. Single photon emission computed tomography/spiral computed tomography fusion imaging for the diagnosis of bone metastasis in patients with known cancer

    International Nuclear Information System (INIS)

    Zhao, Zhen; Li, Lin; Li, Fanglan; Zhao, Lixia

    2010-01-01

    To evaluate single photon emission computed tomography (SPECT)/spiral computed tomography (CT) fusion imaging for the diagnosis of bone metastasis in patients with known cancer and to compare the diagnostic efficacy of SPECT/CT fusion imaging with that of SPECT alone and with SPECT + CT. One hundred forty-one bone lesions of 125 cancer patients (with nonspecific bone findings on bone scintigraphy) were investigated in the study. SPECT, CT, and SPECT/CT fusion images were acquired simultaneously. All images were interpreted independently by two experienced nuclear medicine physicians. In cases of discrepancy, consensus was obtained by a joint reading. The final diagnosis was based on biopsy proof and radiologic follow-up over at least 1 year. The final diagnosis revealed 63 malignant bone lesions and 78 benign lesions. The diagnostic sensitivity of SPECT, SPECT + CT, and SPECT/CT fusion imaging for malignant lesions was 82.5%, 93.7%, and 98.4%, respectively. Specificity was 66.7%, 80.8%, and 93.6%, respectively. Accuracy was 73.8%, 86.5%, and 95.7%, respectively. The specificity and accuracy of SPECT/CT fusion imaging for the diagnosis malignant bone lesions were significantly higher than those of SPECT alone and of SPECT + CT (P 2 = 9.855, P = 0.002). The numbers of equivocal lesions were 37, 18, and 5 for SPECT, SPECT + CT, and SPECT/CT fusion imaging, respectively, and 29.7% (11/37), 27.8% (5/18), and 20.0% (1/5) of lesions were confirmed to be malignant by radiologic follow-up over at least 1 year. SPECT/spiral CT is particularly valuable for the diagnosis of bone metastasis in patients with known cancer by providing precise anatomic localization and detailed morphologic characteristics. (orig.)

  20. Applying standardized uptake values in gallium-67-citrate single-photon emission computed tomography/computed tomography studies and their correlation with blood test results in representative organs.

    Science.gov (United States)

    Toriihara, Akira; Daisaki, Hiromitsu; Yamaguchi, Akihiro; Yoshida, Katsuya; Isogai, Jun; Tateishi, Ukihide

    2018-05-21

    Recently, semiquantitative analysis using standardized uptake value (SUV) has been introduced in bone single-photon emission computed tomography/computed tomography (SPECT/CT). Our purposes were to apply SUV-based semiquantitative analytic method for gallium-67 (Ga)-citrate SPECT/CT and to evaluate correlation between SUV of physiological uptake and blood test results in representative organs. The accuracy of semiquantitative method was validated using an National Electrical Manufacturers Association body phantom study (radioactivity ratio of sphere : background=4 : 1). Thereafter, 59 patients (34 male and 25 female; mean age, 66.9 years) who had undergone Ga-citrate SPECT/CT were retrospectively enrolled in the study. A mean SUV of physiological uptake was calculated for the following organs: the lungs, right atrium, liver, kidneys, spleen, gluteal muscles, and bone marrow. The correlation between physiological uptakes and blood test results was evaluated using Pearson's correlation coefficient. The phantom study revealed only 1% error between theoretical and actual SUVs in the background, suggesting the sufficient accuracy of scatter and attenuation corrections. However, a partial volume effect could not be overlooked, particularly in small spheres with a diameter of less than 28 mm. The highest mean SUV was observed in the liver (range: 0.44-4.64), followed by bone marrow (range: 0.33-3.60), spleen (range: 0.52-2.12), and kidneys (range: 0.42-1.45). There was no significant correlation between hepatic uptake and liver function, renal uptake and renal function, or bone marrow uptake and blood cell count (P>0.05). The physiological uptake in Ga-citrate SPECT/CT can be represented as SUVs, which are not significantly correlated with corresponding blood test results.

  1. Correlation of uptake patterns on single-photon emission computed tomography/computed tomography (SPECT/CT)and treatment response in patients with knee pain

    International Nuclear Information System (INIS)

    Koh, Geon; Hwang, Kyung Hoon; Lee, Hae Jin; Kim, Seog Gyun; Lee, Beom Koo

    2016-01-01

    To determine whether treatment response in patients with knee pain could be predicted using uptake patterns on single-photon emission computed tomography/computed tomography (SPECT/CT) images. Ninety-five patients with knee pain who had undergone SPECT/CT were included in this retrospective study. Subjects were divided into three groups: increased focal uptake (FTU), increased irregular tracer uptake (ITU), and no tracer uptake (NTU). A numeric rating scale (NRS-11) assessed pain intensity. We analyzed the association between uptake patterns and treatment response using Pearson's chi-square test and Fisher's exact test. Uptake was quantified from SPECT/CT with region of interest (ROI) counting, and an intraclass correlation coefficient (ICC) calculated agreement. We used Student' t-test to calculate statistically significant differences of counts between groups and the Pearson correlation to measure the relationship between counts and initial NRS-1k1. Multivariate logistic regression analysis determined which variables were significantly associated with uptake. The FTU group included 32 patients; ITU, 39; and NTU, 24. With conservative management, 64 % of patients with increased tracer uptake (TU, both focal and irregular) and 36 % with NTU showed positive response. Conservative treatment response of FTU was better than NTU, but did not differ from that of ITU. Conservative treatment response of TU was significantly different from that of NTU (OR 3.1; p 0.036). Moderate positive correlation was observed between ITU and initial NRS-11. Age and initial NRS-11 significantly predicted uptake. Patients with uptake in their knee(s) on SPECT/CT showed positive treatment response under conservative treatment

  2. Correlation of uptake patterns on single-photon emission computed tomography/computed tomography (SPECT/CT)and treatment response in patients with knee pain

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Geon; Hwang, Kyung Hoon; Lee, Hae Jin; Kim, Seog Gyun; Lee, Beom Koo [Gachon University Gil Hospital, Incheon (Korea, Republic of)

    2016-06-15

    To determine whether treatment response in patients with knee pain could be predicted using uptake patterns on single-photon emission computed tomography/computed tomography (SPECT/CT) images. Ninety-five patients with knee pain who had undergone SPECT/CT were included in this retrospective study. Subjects were divided into three groups: increased focal uptake (FTU), increased irregular tracer uptake (ITU), and no tracer uptake (NTU). A numeric rating scale (NRS-11) assessed pain intensity. We analyzed the association between uptake patterns and treatment response using Pearson's chi-square test and Fisher's exact test. Uptake was quantified from SPECT/CT with region of interest (ROI) counting, and an intraclass correlation coefficient (ICC) calculated agreement. We used Student' t-test to calculate statistically significant differences of counts between groups and the Pearson correlation to measure the relationship between counts and initial NRS-1k1. Multivariate logistic regression analysis determined which variables were significantly associated with uptake. The FTU group included 32 patients; ITU, 39; and NTU, 24. With conservative management, 64 % of patients with increased tracer uptake (TU, both focal and irregular) and 36 % with NTU showed positive response. Conservative treatment response of FTU was better than NTU, but did not differ from that of ITU. Conservative treatment response of TU was significantly different from that of NTU (OR 3.1; p 0.036). Moderate positive correlation was observed between ITU and initial NRS-11. Age and initial NRS-11 significantly predicted uptake. Patients with uptake in their knee(s) on SPECT/CT showed positive treatment response under conservative treatment.

  3. The predictive value of single-photon emission computed tomography/computed tomography for sentinel lymph node localization in head and neck cutaneous malignancy.

    Science.gov (United States)

    Remenschneider, Aaron K; Dilger, Amanda E; Wang, Yingbing; Palmer, Edwin L; Scott, James A; Emerick, Kevin S

    2015-04-01

    Preoperative localization of sentinel lymph nodes in head and neck cutaneous malignancies can be aided by single-photon emission computed tomography/computed tomography (SPECT/CT); however, its true predictive value for identifying lymph nodes intraoperatively remains unquantified. This study aims to understand the sensitivity, specificity, and positive and negative predictive values of SPECT/CT in sentinel lymph node biopsy for cutaneous malignancies of the head and neck. Blinded retrospective imaging review with comparison to intraoperative gamma probe confirmed sentinel lymph nodes. A consecutive series of patients with a head and neck cutaneous malignancy underwent preoperative SPECT/CT followed by sentinel lymph node biopsy with a gamma probe. Two nuclear medicine physicians, blinded to clinical data, independently reviewed each SPECT/CT. Activity within radiographically defined nodal basins was recorded and compared to intraoperative gamma probe findings. Sensitivity, specificity, and negative and positive predictive values were calculated with subgroup stratification by primary tumor site. Ninety-two imaging reads were performed on 47 patients with cutaneous malignancy who underwent SPECT/CT followed by sentinel lymph node biopsy. Overall sensitivity was 73%, specificity 92%, positive predictive value 54%, and negative predictive value 96%. The predictive ability of SPECT/CT to identify the basin or an adjacent basin containing the single hottest node was 92%. SPECT/CT overestimated uptake by an average of one nodal basin. In the head and neck, SPECT/CT has higher reliability for primary lesions of the eyelid, scalp, and cheek. SPECT/CT has high sensitivity, specificity, and negative predictive value, but may overestimate relevant nodal basins in sentinel lymph node biopsy. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  4. Differentiation of myocardial ischemia and infarction assessed by dynamic computed tomography perfusion imaging and comparison with cardiac magnetic resonance and single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tanabe, Yuki; Kido, Teruhito; Kurata, Akira; Miyagawa, Masao; Mochizuki, Teruhito [Ehime University Graduate School of Medicine, Department of Radiology, Toon, Ehime (Japan); Uetani, Teruyoshi; Kono, Tamami; Ogimoto, Akiyoshi [Ehime University Graduate School of Medicine, Department of Cardiology, Pulmonology, Hypertension and Nephrology, Toon, Ehime (Japan); Soma, Tsutomu [FUJIFILM RI Pharma Co., Ltd., QMS Group, Quality Assurance Department, Tokyo (Japan); Graduate School of Medicine, University of Tokyo, Department of Radiology, Tokyo (Japan); Murase, Kenya [Osaka University Graduate School of Medicine, Department of Medical Physics and Engineering, Division of Medical Technology and Science, Faculty of Health Science, Osaka (Japan); Iwaki, Hirotaka [Ehime University Graduate School of Medicine, Center for Clinical Research Data and Biostatistics, Toon, Ehime (Japan)

    2016-11-15

    To evaluate the feasibility of myocardial blood flow (MBF) by computed tomography from dynamic CT perfusion (CTP) for detecting myocardial ischemia and infarction assessed by cardiac magnetic resonance (CMR) or single-photon emission computed tomography (SPECT). Fifty-three patients who underwent stress dynamic CTP and either SPECT (n = 25) or CMR (n = 28) were retrospectively selected. Normal and abnormal perfused myocardium (ischemia/infarction) were assessed by SPECT/CMR using 16-segment model. Sensitivity and specificity of CT-MBF (mL/g/min) for detecting the ischemic/infarction and severe infarction were assessed. The abnormal perfused myocardium and severe infarction were seen in SPECT (n = 90 and n = 19 of 400 segments) and CMR (n = 223 and n = 36 of 448 segments). For detecting the abnormal perfused myocardium, sensitivity and specificity were 80 % (95 %CI, 71-90) and 86 % (95 %CI, 76-91) in SPECT (cut-off MBF, 1.23), and 82 % (95 %CI, 76-88) and 87 % (95 %CI, 80-92) in CMR (cut-off MBF, 1.25). For detecting severe infarction, sensitivity and specificity were 95 % (95 %CI, 52-100) and 72 % (95 %CI, 53-91) in SPECT (cut-off MBF, 0.92), and 78 % (95 %CI, 67-97) and 80 % (95 %CI, 58-86) in CMR (cut-off MBF, 0.98), respectively. Dynamic CTP has a potential to detect abnormal perfused myocardium and severe infarction assessed by SPECT/CMR using comparable cut-off MBF. (orig.)

  5. Prospective, blinded trial of whole-body magnetic resonance imaging versus computed tomography positron emission tomography in staging primary and recurrent cancer of the head and neck.

    LENUS (Irish Health Repository)

    O'Neill, J P

    2012-02-01

    OBJECTIVES: To compare the use of computed tomography - positron emission tomography and whole-body magnetic resonance imaging for the staging of head and neck cancer. PATIENTS AND METHODS: From January to July 2009, 15 consecutive head and neck cancer patients (11 men and four women; mean age 59 years; age range 19 to 81 years) underwent computed tomography - positron emission tomography and whole-body magnetic resonance imaging for pre-therapeutic evaluation. All scans were staged, as per the American Joint Committee on Cancer tumour-node-metastasis classification, by two blinded consultant radiologists, in two sittings. Diagnoses were confirmed by histopathological examination of endoscopic biopsies, and in some cases whole surgical specimens. RESULTS: Tumour staging showed a 74 per cent concordance, node staging an 80 per cent concordance and metastasis staging a 100 per cent concordance, comparing the two imaging modalities. CONCLUSION: This study found radiological staging discordance between the two imaging modalities. Whole-body magnetic resonance imaging is an emerging staging modality with superior visualisation of metastatic disease, which does not require exposure to ionising radiation.

  6. Emission computed tomography with technetium-99m pyrophosphate for delineating location and size of acute myocardial infarction in man

    Energy Technology Data Exchange (ETDEWEB)

    Tamaki, S; Kadota, K; Kambara, H; Suzuki, Y; Nohara, R; Murakami, T; Kawai, C; Tamaki, N; Torizuka, K [Kyoto Univ. (Japan). Faculty of Medicine

    1984-07-01

    Emission computed tomography with technetium-99m pyrophosphate was used to delineate the location and estimate the size of myocardial infarcts in 20 patients with documented acute myocardial infarction. Tomography was performed after planar imaging within 2-5 days after the onset of infarction. Infarct volume was measured from the tomographic images by computerised planimetry and compared with the cumulative release of creatine kinase MB isoenzyme. The planar images showed discrete myocardial uptake in 13 of the 20 patients and diffuse uptake throughout the cardiac region in the remaining seven. In contrast, the tomographic images clearly delineated myocardial uptake by avoiding confusion of myocardial activity with that of surrounding structures, particularly bones, in all patients. For the 10 patients whose infarct size was assessed by analysis of the creatine kinase MB curve there was a close correlation between infarct volume estimated by tomography and by cumulative creatine kinase MB release. Thus emission computed tomography can provide a three dimensional map of technetium-99m pyrophosphate distribution within the heart and is thus able accurately to localise and estimate the size of myocardial infarcts in man.

  7. Emission computed tomography with technetium-99m pyrophosphate for delineating location and size of acute myocardial infarction in man

    International Nuclear Information System (INIS)

    Tamaki, S.; Kadota, K.; Kambara, H.; Suzuki, Y.; Nohara, R.; Murakami, T.; Kawai, C.; Tamaki, N.; Torizuka, K.

    1984-01-01

    Emission computed tomography with technetium-99m pyrophosphate was used to delineate the location and estimate the size of myocardial infarcts in 20 patients with documented acute myocardial infarction. Tomography was performed after planar imaging within 2-5 days after the onset of infarction. Infarct volume was measured from the tomographic images by computerised planimetry and compared with the cumulative release of creatine kinase MB isoenzyme. The planar images showed discrete myocardial uptake in 13 of the 20 patients and diffuse uptake throughout the cardiac region in the remaining seven. In contrast, the tomographic images clearly delineated myocardial uptake by avoiding confusion of myocardial activity with that of surrounding structures, particularly bones, in all patients. For the 10 patients whose infarct size was assessed by analysis of the creatine kinase MB curve there was a close correlation between infarct volume estimated by tomography and by cumulative creatine kinase MB release. Thus emission computed tomography can provide a three dimensional map of technetium-99m pyrophosphate distribution within the heart and is thus able accurately to localise and estimate the size of myocardial infarcts in man. (author)

  8. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.

    1986-01-01

    Computed tomography is regarded by many as a complicated union of sophisticated x-ray equipment and computer technology. This book overcomes these complexities. The rigid technicalities of the machinery and the clinical aspects of computed tomography are discussed including the preparation of patients, both physically and mentally, for scanning. Furthermore, the author also explains how to set up and run a computed tomography department, including advice on how the room should be designed

  9. Somatostatin receptor positron emission tomography/computed tomography (PET/CT) in the evaluation of opsoclonus-myoclonus ataxia syndrome

    International Nuclear Information System (INIS)

    Joshi, Prathamesh; Lele, Vikram

    2013-01-01

    Opsoclonus-myoclonus ataxia (OMA) syndrome is the most common paraneoplastic neurological syndrome of childhood, associated with occult neuroblastoma in 20%-50% of all cases. OMA is the initial presentation of neuroblastoma in 1%-3% of children. Conventional radiological imaging approaches include chest radiography and abdominal computed tomography (CT). Nuclear medicine techniques, in form of 123 I/ 131 I-metaiodobenzylguanidine (MIBG) scintigraphy have been incorporated in various diagnostic algorithms for evaluation of OMA. We describe use of somatostatin receptor PET/CT with 68 Gallium- DOTA-DPhe 1 , Tyr 3 -octreotate (DOTATATE) in diagnosis of neuroblastoma in two cases of OMA

  10. Somatostatin receptor positron emission tomography/computed tomography (PET/CT) in the evaluation of opsoclonus-myoclonus ataxia syndrome.

    Science.gov (United States)

    Joshi, Prathamesh; Lele, Vikram

    2013-04-01

    Opsoclonus-myoclonus ataxia (OMA) syndrome is the most common paraneoplastic neurological syndrome of childhood, associated with occult neuroblastoma in 20%-50% of all cases. OMA is the initial presentation of neuroblastoma in 1%-3% of children. Conventional radiological imaging approaches include chest radiography and abdominal computed tomography (CT). Nuclear medicine techniques, in form of (123)I/(131)I-metaiodobenzylguanidine (MIBG) scintigraphy have been incorporated in various diagnostic algorithms for evaluation of OMA. We describe use of somatostatin receptor PET/CT with (68)Gallium- DOTA-DPhe(1), Tyr(3)-octreotate (DOTATATE) in diagnosis of neuroblastoma in two cases of OMA.

  11. Prediction of Central Nervous System Relapse of Diffuse Large B-Cell Lymphoma Using Pretherapeutic [18F]2-Fluoro-2-Deoxyglucose (FDG) Positron Emission Tomography/Computed Tomography.

    Science.gov (United States)

    Song, Yoo Sung; Lee, Won Woo; Lee, Jong Seok; Kim, Sang Eun

    2015-11-01

    Central nervous system (CNS) relapse of diffuse large B-cell lymphoma (DLBCL) is a rare complication, but has a poor prognosis with unknown pathophysiology. Recent trials of CNS prophylaxis have shown to be ineffective, despite patient's selection using several known clinical risk factors. In this study, the authors evaluated the value of pretreatment [F]2-Fluoro-2-deoxyglucose positron emission tomography in predicting CNS relapse in DLBCL patients.The authors analyzed 180 pathologically confirmed DLBCL patients, retrospectively. Patients underwent [F]2-Fluoro-2-deoxyglucose positron emission tomography/computed tomography before first line rituximab to cyclophosphamide, doxorubicin, vincristine, and prednisone therapy. Clinical characteristics were evaluated and total lesion glycolysis (TLG) with a threshold margin of 50% was calculated.Among age, sex, Ann Arbor stage, International Prognostic Index, revised International Prognostic Index, high serum lactate dehydrogenase level, presence of B symptoms, bulky disease (≥10 cm), extranodal lesion involvement, bone marrow involvement, high metabolic tumor volume ( >450 mL), and high TLG50 (>2000), the high TLG50 was the only significant prognostic factor for predicting CNS relapse in a multivariate analysis (P = 0.04). Kaplan-Meir survival analysis between high TLG50 (>2000) and low TLG50 (≤2000) groups revealed significantly different mean progression free survival (PFS) of 1317.2 ± 134.3 days and 1968.6 ± 18.3 days, respectively (P positron emission tomography/computed tomography is the most significant predictor of CNS relapse in un-treated DLBCL patients.

  12. Positron emission tomography

    International Nuclear Information System (INIS)

    Chandrasekhar, Preethi; Himabindu, Pucha

    2000-01-01

    Positron Emission Tomography (PET) is a non-invasive nuclear imaging technique used to study different molecular pathways and anatomical structures. PET has found extensive applications in various fields of medicine viz. cardiology, oncology, psychiatry/psychology, neuro science and pulmonology. This study paper basically deals with the physics, chemistry and biology behind the PET technique. It discusses the methodology for generation of the radiotracers responsible for emission of positrons and the annihilation and detection techniques. (author)

  13. Feasibility of optimizing the dose distribution in lung tumors using fluorine-18-fluorodeoxyglucose positron emission tomography and single photon emission computed tomography guided dose prescriptions

    International Nuclear Information System (INIS)

    Das, S.K.; Miften, M.M.; Zhou, S.; Bell, M.; Munley, M.T.; Whiddon, C.S.; Craciunescu, O.; Baydush, A.H.; Wong, T.; Rosenman, J.G.; Dewhirst, M.W.; Marks, L.B.

    2004-01-01

    The information provided by functional images may be used to guide radiotherapy planning by identifying regions that require higher radiation dose. In this work we investigate the dosimetric feasibility of delivering dose to lung tumors in proportion to the fluorine-18-fluorodeoxyglucose activity distribution from positron emission tomography (FDG-PET). The rationale for delivering dose in proportion to the tumor FDG-PET activity distribution is based on studies showing that FDG uptake is correlated to tumor cell proliferation rate, which is shown to imply that this dose delivery strategy is theoretically capable of providing the same duration of local control at all voxels in tumor. Target dose delivery was constrained by single photon emission computed tomography (SPECT) maps of normal lung perfusion, which restricted irradiation of highly perfused lung and imposed dose-function constraints. Dose-volume constraints were imposed on all other critical structures. All dose-volume/function constraints were considered to be soft, i.e., critical structure doses corresponding to volume/function constraint levels were minimized while satisfying the target prescription, thus permitting critical structure doses to minimally exceed dose constraint levels. An intensity modulation optimization methodology was developed to deliver this radiation, and applied to two lung cancer patients. Dosimetric feasibility was assessed by comparing spatially normalized dose-volume histograms from the nonuniform dose prescription (FDG-PET proportional) to those from a uniform dose prescription with equivalent tumor integral dose. In both patients, the optimization was capable of delivering the nonuniform target prescription with the same ease as the uniform target prescription, despite SPECT restrictions that effectively diverted dose from high to low perfused normal lung. In one patient, both prescriptions incurred similar critical structure dosages, below dose-volume/function limits

  14. Positron emission tomography

    International Nuclear Information System (INIS)

    Pavuk, M.

    2003-12-01

    The aim of this project is to provide a simple summary of new trends in positron emission tomography and its basic physical principles. It provides thereby compendious introduction of the trends of the present development in diagnostics using PET systems. A review of available literature was performed. (author)

  15. Positron emission tomography

    NARCIS (Netherlands)

    Paans, AMJ

    Positron Emission Tomography (PET) is a method for determining biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides as C-11, N-13, O-15 and F-18 and by measuring the annihilation radiation using a

  16. Positron emission tomography response criteria in solid tumours criteria for quantitative analysis of [18F]-fluorodeoxyglucose positron emission tomography with integrated computed tomography for treatment response assessment in metastasised solid tumours: All that glitters is not gold.

    Science.gov (United States)

    Willemsen, Annelieke E C A B; Vlenterie, Myrella; van Herpen, Carla M L; van Erp, Nielka P; van der Graaf, Winette T A; de Geus-Oei, Lioe-Fee; Oyen, Wim J G

    2016-03-01

    For solid tumours, quantitative analysis of [(18)F]-fluorodeoxyglucose positron emission tomography with integrated computed tomography potentially can have significant value in early response assessment and thereby discrimination between responders and non-responders at an early stage of treatment. Standardised strategies for this analysis have been proposed, and the positron emission tomography response criteria in solid tumours (PERCIST) criteria can be regarded as the current standard to perform quantitative analysis in a research setting, yet is not implemented in daily practice. However, several exceptions and limitations limit the feasibility of PERCIST criteria. In this article, we point out dilemmas that arise when applying proposed criteria like PERCIST on an expansive set of patients with metastasised solid tumours. Clinicians and scientists should be aware of these limitations to prevent that methodological issues impede successful introduction of research data into clinical practice. Therefore, to deliver on the high potential of quantitative imaging, consensus should be reached on a standardised, feasible and clinically useful analysis methodology. This methodology should be applicable in the majority of patients, tumour types and treatments. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Single photon emission computed tomography (SPECT of anxiety disorders before and after treatment with citalopram

    Directory of Open Access Journals (Sweden)

    Seedat Soraya

    2004-10-01

    Full Text Available Abstract Background Several studies have now examined the effects of selective serotonin reuptake inhibitor (SSRI treatment on brain function in a variety of anxiety disorders including obsessive-compulsive disorder (OCD, posttraumatic stress disorder (PTSD, and social anxiety disorder (social phobia (SAD. Regional changes in cerebral perfusion following SSRI treatment have been shown for all three disorders. The orbitofrontal cortex (OFC (OCD, caudate (OCD, medial pre-frontal/cingulate (OCD, SAD, PTSD, temporal (OCD, SAD, PTSD and, thalamic regions (OCD, SAD are some of those implicated. Some data also suggests that higher perfusion pre-treatment in the anterior cingulate (PTSD, OFC, caudate (OCD and antero-lateral temporal region (SAD predicts subsequent treatment response. This paper further examines the notion of overlap in the neurocircuitry of treatment and indeed treatment response across anxiety disorders with SSRI treatment. Methods Single photon emission computed tomography (SPECT using Tc-99 m HMPAO to assess brain perfusion was performed on subjects with OCD, PTSD, and SAD before and after 8 weeks (SAD and 12 weeks (OCD and PTSD treatment with the SSRI citalopram. Statistical parametric mapping (SPM was used to compare scans (pre- vs post-medication, and responders vs non-responders in the combined group of subjects. Results Citalopram treatment resulted in significant deactivation (p = 0.001 for the entire group in the superior (t = 4.78 and anterior (t = 4.04 cingulate, right thalamus (t = 4.66 and left hippocampus (t = 3.96. Deactivation (p = 0.001 within the left precentral (t = 4.26, right mid-frontal (t = 4.03, right inferior frontal (t = 3.99, left prefrontal (3.81 and right precuneus (t= 3.85 was more marked in treatment responders. No pattern of baseline activation distinguished responders from non-responders to subsequent pharmacotherapy. Conclusions Although each of the anxiety disorders may be mediated by different

  18. Positron Emission Tomography/Computed Tomography-Guided Intensity-Modulated Radiotherapy for Limited-Stage Small-Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Shirvani, Shervin M.; Komaki, Ritsuko [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Heymach, John V.; Fossella, Frank V. [Department of Thoracic/Head and Neck Medical Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Chang, Joe Y., E-mail: jychang@mdanderson.org [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States)

    2012-01-01

    Purpose: Omitting elective nodal irradiation from planning target volumes does not compromise outcomes in patients with non-small-cell lung cancer, but whether the same is true for those with limited-stage small-cell lung cancer (LS-SCLC) is unknown. Therefore, in the present study, we sought to determine the clinical outcomes and the frequency of elective nodal failure in patients with LS-SCLC staged using positron emission tomography/computed tomography and treated with involved-field intensity-modulated radiotherapy. Methods and Materials: Between 2005 and 2008, 60 patients with LS-SCLC at our institution underwent disease staging using positron emission tomography/computed tomography before treatment using an intensity-modulated radiotherapy plan in which elective nodal irradiation was intentionally omitted from the planning target volume (mode and median dose, 45 Gy in 30 fractions; range, 40.5 Gy in 27 fractions to 63.8 Gy in 35 fractions). In most cases, concurrent platinum-based chemotherapy was administered. We retrospectively reviewed the clinical outcomes to determine the overall survival, relapse-free survival, and failure patterns. Elective nodal failure was defined as recurrence in initially uninvolved hilar, mediastinal, or supraclavicular nodes. Survival was assessed using the Kaplan-Meier method. Results: The median age of the study patients at diagnosis was 63 years (range, 39-86). The median follow-up duration was 21 months (range, 4-58) in all patients and 26 months (range, 4-58) in the survivors. The 2-year actuarial overall survival and relapse-free survival rate were 58% and 43%, respectively. Of the 30 patients with recurrence, 23 had metastatic disease and 7 had locoregional failure. We observed only one isolated elective nodal failure. Conclusions: To our knowledge, this is the first study to examine the outcomes in patients with LS-SCLC staged with positron emission tomography/computed tomography and treated with definitive intensity

  19. Positron Emission Tomography/Computed Tomography-Guided Intensity-Modulated Radiotherapy for Limited-Stage Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Shirvani, Shervin M.; Komaki, Ritsuko; Heymach, John V.; Fossella, Frank V.; Chang, Joe Y.

    2012-01-01

    Purpose: Omitting elective nodal irradiation from planning target volumes does not compromise outcomes in patients with non–small-cell lung cancer, but whether the same is true for those with limited-stage small-cell lung cancer (LS-SCLC) is unknown. Therefore, in the present study, we sought to determine the clinical outcomes and the frequency of elective nodal failure in patients with LS-SCLC staged using positron emission tomography/computed tomography and treated with involved-field intensity-modulated radiotherapy. Methods and Materials: Between 2005 and 2008, 60 patients with LS-SCLC at our institution underwent disease staging using positron emission tomography/computed tomography before treatment using an intensity-modulated radiotherapy plan in which elective nodal irradiation was intentionally omitted from the planning target volume (mode and median dose, 45 Gy in 30 fractions; range, 40.5 Gy in 27 fractions to 63.8 Gy in 35 fractions). In most cases, concurrent platinum-based chemotherapy was administered. We retrospectively reviewed the clinical outcomes to determine the overall survival, relapse-free survival, and failure patterns. Elective nodal failure was defined as recurrence in initially uninvolved hilar, mediastinal, or supraclavicular nodes. Survival was assessed using the Kaplan-Meier method. Results: The median age of the study patients at diagnosis was 63 years (range, 39–86). The median follow-up duration was 21 months (range, 4–58) in all patients and 26 months (range, 4–58) in the survivors. The 2-year actuarial overall survival and relapse-free survival rate were 58% and 43%, respectively. Of the 30 patients with recurrence, 23 had metastatic disease and 7 had locoregional failure. We observed only one isolated elective nodal failure. Conclusions: To our knowledge, this is the first study to examine the outcomes in patients with LS-SCLC staged with positron emission tomography/computed tomography and treated with definitive

  20. Positron Emission Tomography/Magnetic Resonance Imaging for Local Tumor Staging in Patients With Primary Breast Cancer: A Comparison With Positron Emission Tomography/Computed Tomography and Magnetic Resonance Imaging.

    Science.gov (United States)

    Grueneisen, Johannes; Nagarajah, James; Buchbender, Christian; Hoffmann, Oliver; Schaarschmidt, Benedikt Michael; Poeppel, Thorsten; Forsting, Michael; Quick, Harald H; Umutlu, Lale; Kinner, Sonja

    2015-08-01

    This study aimed to assess the diagnostic performance of integrated positron emission tomography (PET)/magnetic resonance imaging (MRI) of the breast for lesion detection and local tumor staging of patients with primary breast cancer in comparison to PET/computed tomography (CT) and MRI. The study was approved by the local institutional review board. Forty-nine patients with biopsy-proven invasive breast cancer were prospectively enrolled in our study. All patients underwent a PET/CT, and subsequently, a contrast-enhanced PET/MRI of the breast after written informed consent was obtained before each examination. Two radiologists independently evaluated the corresponding data sets (PET/CT, PET/MRI, and MRI) and were instructed to identify primary tumors lesions as well as multifocal/multicentric and bilateral disease. Furthermore, the occurrence of lymph node metastases was assessed, and the T-stage for each patient was determined. Histopathological verification of the local tumor extent and the axillary lymph node status was available for 30 of 49 and 48 of 49 patients, respectively. For the remaining patients, a consensus characterization was performed for the determination of the T-stage and nodal status, taking into account the results of clinical staging, PET/CT, and PET/MRI examinations. Statistical analysis was performed to test for differences in diagnostic performance between the different imaging procedures. P values less than 0.05 were considered to be statistically significant. Positron emission tomography/MRI and MRI correctly identified 47 (96%) of the 49 patients with primary breast cancer, whereas PET/CT enabled detection of 46 (94%) of 49 breast cancer patients and missed a synchronous carcinoma in the contralateral breast in 1 patient. In a lesion-by-lesion analysis, no significant differences could be obtained between the 3 imaging procedures for the identification of primary breast cancer lesions (P > 0.05). Positron emission tomography/MRI and

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  2. Positron emission tomography

    International Nuclear Information System (INIS)

    Marchenkov, N.S.

    2000-01-01

    The foundations of the positron emission tomography (PET), widely used for the medical diagnostics, are considered. The brief description of the cyclotron for production of radionuclides, applied in the PET, the target devices for manufacturing the position emitters, the moduli for the radiopharmaceuticals synthesis (RPS) for the PET is presented. The necessity and concept of complete automation of the RPS for the PET are discussed [ru

  3. Positron emission tomography

    International Nuclear Information System (INIS)

    Paans, A.M.J.

    1981-01-01

    Positron emitting radiopharmaceuticals have special applications in in-vivo studies of biochemical processes. The combination of a cyclotron for the production of radionuclides and a positron emission tomograph for the registration of the distribution of radioactivity in the body enables the measurement of local radioactivity concentration in tissues, and opens up new possibilities in the diagnosis and examination of abnormalities in the metabolism. The principles and procedures of positron emission tomography are described and the necessary apparatus considered, with emphasis on the positron camera. The first clinical applications using 55 Co bloemycine for tumor detection are presented. (C.F.)

  4. Effect of expression of P-glycoprotein on technetium-99m methoxyisobutylisonitrile single photon emission computed tomography of brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Yasushi; Matsumura, Akira; Nose, Tadao [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2002-08-01

    The expression of P-glycoprotein was investigated imunohistochemically in 26 brain tumor tissues and compared with the findings of technetium-99m methoxyisobutylisonitrile single photon emission computed tomography ({sup 99m}Tc-MIBI SPECT) to clarify the effect of P-glycoprotein on the diagnostic accuracy. P-glycoprotein labeling index of both tumor cells and vascular endothelial cells showed no clear relationship with the findings of {sup 99m}Tc-MIBI SPECT imaging. Expression of P-glycoprotein has no effect on the diagnostic accuracy of {sup 99m}Tc-MIBI SPECT. (author)

  5. Evaluative studies in nuclear medicine research. Emission-computed tomography assessment. Progress report 1 January-15 August 1981

    International Nuclear Information System (INIS)

    Potchen, E.J.

    1981-01-01

    Questions regarding what imaging performance goals need to be met to produce effective biomedical research using positron emission computer tomography, how near those performance goals are to being realized by imaging systems, and the dependence of currently-unachieved performance goals on design and operational factors have been addressed in the past year, along with refinement of economic estimates for the capital and operating costs of a PECT research facility. The two primary sources of information have been solicitations of expert opinion and review of current literature

  6. Preoperative lymph-node staging of invasive urothelial bladder cancer with 18F-fluorodeoxyglucose positron emission tomography/computed axial tomography and magnetic resonance imaging

    DEFF Research Database (Denmark)

    Jensen, Thor Knak; Holt, Per; Gerke, Oke

    2011-01-01

    OBJECTIVE: The treatment and prognosis of bladder cancer are based on the depth of primary tumour invasion and the presence of metastases. A highly accurate preoperative tumour, node, metastasis (TNM) staging is critical to proper patient management and treatment. This study retrospectively...... investigated the value of ¹⁸F-fluorodeoxyglucose (FDG) positron emission tomography/computed axial tomography (¹⁸F-FDG PET/CT) and magnetic resonance imaging (MRI) for preoperative N staging of bladder cancer. Material and methods. From June 2006 to January 2008, 48 consecutive patients diagnosed with bladder......) for MRI and ¹⁸F-FDG PET/CT, respectively. The differences in specificity and negative predictive values were not statistically significant. Conclusions. No significant statistical difference between ¹⁸F-FDG PET/CT and MRI for preoperative N staging of urothelial bladder cancer was found in the study...

  7. Assessment of skull base involvement in nasopharyngeal carcinoma: comparisons of single-photon emission tomography with planar bone scintigraphy and X-ray computed tomography

    International Nuclear Information System (INIS)

    Lee Chianghsuan; Wang Peiwen; Chen Hueyong; Lui Chunchung; Su Chihying

    1995-01-01

    The diagnostic contribution of single-photon emission tomography (SPET) to the detection of bone lesions of the skull base was explored in 200 patients with nasopharyngeal carcinoma (NPC). Comparison of SPET with planar bone scintigraphy showed that SPET improved the contrast and better defined the lesions in 107 out of the 200 patients. Comparison of SPET with X-ray computed tomography (CT) showed that SPET did not miss the lesions detected by CT while CT missed 49% of the lesions detected by SPET. The only false-positive lesion with SPET was detected in the mastoid bone. SPET detected skull base lesions in all of the 35 patients with cranial nerve involvement, while CT missed eight and planar bone scintigraphy missed four. The findings suggest that SPET should be included in the routine check-up examinations of patients with NPC. (orig.)

  8. Isolated thymic Langerhans cell histiocytosis discovered on F-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT).

    Science.gov (United States)

    Turpin, Sophie; Carret, Anne-Sophie; Dubois, Josée; Buteau, Chantal; Patey, Natalie

    2015-11-01

    The thymic infiltration in young patients with multisystemic Langerhans cell histiocytosis and its radiologic features are well known. However, isolated thymic disease has seldom been reported in the literature. We report the case of a 10-month-old child admitted for fever of unknown origin. Whole-body F-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) was performed to identify a focus of infection. It demonstrated an unusual aspect of the thymus, which led to further investigation and revealed isolated infiltration of the thymus by Langerhans cell histiocytosis. The patient was treated accordingly and is now disease free. As evaluation of Langerhans cell histiocytosis patients with F-18 FDG PET/CT is becoming more frequent, it is important to be aware of the scintigraphical characteristics of thymic Langerhans cell histiocytosis.

  9. False-positive 18F-fluorodeoxyglucose positron emission tomography/computed tomography in a patient with metallic implants following chondrosarcoma resection.

    Science.gov (United States)

    Zhou, P U; Tang, Jinliang; Zhang, Dong; Li, Guanghui

    2016-05-01

    Positron emission tomography (PET) with fluorine-18-labeled fluorodeoxyglucose ( 18 F-FDG) has been used for the staging and evaluation of recurrence in cancer patients. We herein report a false-positive result of 18 F-FDG PET/computed tomography (CT) scan in a patient following chondrosarcoma resection and metallic implanting. A 35-year-old male patient with chondrosarcoma of the left iliac bone underwent radical resection, metal brace implanting and radiotherapy. A high uptake of 18 F-FDG was observed in the metallic implants and adjacent tissue during PET/CT scanning in the 5th year of follow-up. Tissue biopsy and follow-up examination identified no tumor recurrence or infection at these sites, suggesting that the results of 18 F-FDG PET/CT must be interpreted with caution in cancer patients with metallic implants.

  10. Fluorodeoxyglucose positron emission tomography-computed tomography scan in von Hippel-Lindau syndrome: a case report and review of literature

    International Nuclear Information System (INIS)

    Solav, Shrikant; Bhandari, Ritu

    2012-01-01

    Von Hippel-Lindau (VHL) syndrome is a hereditary autosomal dominant disorder caused by defective tumor suppression gene at 3p25-p26. The gene for VHL disease is found on chromosome 3, and is inherited in a dominant fashion. The VHL gene is a tumor suppressor gene. This means that its role in a normal cell is to stop the uncontrolled growth and proliferation. It is characterized by abnormal growth of blood vessels. It strikes the eyes, central nervous system, kidneys, endocrine glands, etc. It predisposes the patient to retinal angiomas, central nervous system hemangioblastoma, renal cell carcinoma (RCC), pheochromocytomas, islet cell tumor of the pancreas, endolymphatic sac tumors, renal, pancreatic, epididymal cysts. We present a case of familial VHL syndrome whose Fluorine 18-fluorodeoxyglucose positron emission tomography-computed tomography scan was truly positive for adrenal pheochromocytoma but was falsely negative for RCC. Review of literature related to this entity is made. (author)

  11. Gallium-68 DOTA-TATE Positron Emission Tomography/Computed Tomography: Scintigraphic Changes of Adrenal Glands Following Management of Ectopic Cushing's Syndrome by Steroidogenesis Inhibitors

    International Nuclear Information System (INIS)

    Huang, Yu-Ting; Aziz, Shaikh Irfan; Kumar, Aravind S. Ravi

    2014-01-01

    In the era of emerging functional imaging techniques, an understanding of the effects of hormonal therapies on the scintigraphic appearance of endocrine organs is desirable to minimize the erroneous scan interpretation. The mechanisms by which changes in the scintigraphic appearance of endocrine organs occur however sometimes remain ambiguous. This case demonstrates the gallium-68 (Ga-68) DOTA-TATE positron emission tomography/computed tomography (CT) appearance of adrenal glands following management with steroidogenesis inhibitors. The potential mechanisms underlying this change are discussed. A 17-year-old boy with adrenocorticotropic hormone (ACTH) dependent Cushing's syndrome secondary to ectopic ACTH secretion underwent pre- and post-metyrapone and dexamethasone treatment Ga-68 DOTA-TATE scans 4 months apart. Pretreatment, both adrenals demonstrated normal symmetrical prominent Ga-68 DOTA-TATE uptake and normal CT appearance. The posttherapy scan revealed marked symmetrical suppression of Ga-68 DOTA-TATE uptake, but with bilateral adrenal hypertrophy on CT

  12. Post meningitis subdural hygroma: anatomical and functional evaluation with 99mTc-ethylene cysteine dimer single photon emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Sharma, Punit; Mishra, Ajiv; Arora, Geetanjali; Tripathi, Madhavi; Bal, Chandrasekhar; Kumar, Rakesh

    2013-01-01

    Subdural hygroma is the collection of cerebrospinal fluid in the subdural space. Most often these resolve spontaneously. However, in cases with neurological complications surgical drainage may be needed. We here, present the case of an 8-year-old boy with post meningitis subdural hygroma. 99m Tc-ethylene cysteine dimer ( 99m Tc-ECD) hybrid single photon emission tomography/computed tomography (SPECT/CT) carried out in this patient, demonstrated the subdural hygroma as well as the associated cerebral hypoperfusion. If 99m Tc-ECD SPECT/CT is integrated into management of these patients, it can help in decision making with respect to conservative versus surgical management. (author)

  13. "6"8Gallium-arginine-glycine-aspartic acid and "1"8F-fluorodeoxyglucose position emission tomography/computed tomography in chondroblastic osteosarcoma of the skull

    International Nuclear Information System (INIS)

    Orunmuyi, Akintunde; Modiselle, Moshe; Lengana, Thabo; Ebenhan, Thomas; Vorster, Mariza; Sathekge, Mike

    2017-01-01

    We report the case of a 32 year-old male with Chondroblastic Osteosarcoma of the skull, which was imaged with both "1"8[F]fluorodeoxyglucose ("1"8F-FDG) positron emission tomography/computed tomography (PET/CT) and "6"8Gallium-arginine-glycine-aspartic acid ("6"8Ga-RGD) PET/CT. The "1"8F-FDG PET/CT did not demonstrate the tumour, whereas the "6"8Ga-RGD PET/CT clearly depicted a left-sided frontal tumour. "6"8Ga-RGD PET/CT may be a clinically useful imaging modality for early detection of recurrent osteosarcoma, considering the limitations of "1"8F-FDG PET in a setting of low glycolytic activity

  14. Isolated thymic Langerhans cell histiocytosis discovered on F-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT)

    Energy Technology Data Exchange (ETDEWEB)

    Turpin, Sophie [CHU Sainte-Justine, Nuclear Medicine, Montreal (Canada); Carret, Anne-Sophie [CHU Sainte-Justine, Hemato-Oncology, Montreal (Canada); Dubois, Josee [CHU Sainte-Justine, Radiology, Montreal (Canada); Buteau, Chantal [CHU Sainte-Justine, Infectious Diseases, Montreal (Canada); Patey, Natalie [CHU Sainte-Justine, Pathology, Montreal (Canada)

    2015-11-15

    The thymic infiltration in young patients with multisystemic Langerhans cell histiocytosis and its radiologic features are well known. However, isolated thymic disease has seldom been reported in the literature. We report the case of a 10-month-old child admitted for fever of unknown origin. Whole-body F-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) was performed to identify a focus of infection. It demonstrated an unusual aspect of the thymus, which led to further investigation and revealed isolated infiltration of the thymus by Langerhans cell histiocytosis. The patient was treated accordingly and is now disease free. As evaluation of Langerhans cell histiocytosis patients with F-18 FDG PET/CT is becoming more frequent, it is important to be aware of the scintigraphical characteristics of thymic Langerhans cell histiocytosis. (orig.)

  15. Infective endocarditis detected by 18F-fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography in a patient with occult infection

    Directory of Open Access Journals (Sweden)

    Chia-Lu Yeh

    2011-11-01

    Full Text Available Integrated 18F-fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography (FDG PET/CT has been clinically used to detect infectious lesions. We present a case with pyrexia and bacteremia of unknown origin. Whole body FDG PET/CT was arranged to look for an occult source of infection and it revealed a focal lesion with increased FDG uptake in the mitral valve area. Under suspicion of infective endocarditis, transthoracic echocardiography was repeated and then the presence of linear vegetation over the calcified mitral annulus was confirmed. Ultimately, definite infective endocarditis was diagnosed according to the Duke criteria. The patient recovered after the antibiotic therapy. In our case, FDG PET/CT can help to localize the exact site of occult infection, thereby guiding additional testing and facilitating timely definitive diagnosis and therapy.

  16. {sup 68}Gallium-arginine-glycine-aspartic acid and {sup 18}F-fluorodeoxyglucose position emission tomography/computed tomography in chondroblastic osteosarcoma of the skull

    Energy Technology Data Exchange (ETDEWEB)

    Orunmuyi, Akintunde; Modiselle, Moshe; Lengana, Thabo; Ebenhan, Thomas; Vorster, Mariza; Sathekge, Mike [Dept. of Nuclear MedicineUniversity of Pretoria and Steve Biko Academic Hospital, Pretoria (South Africa)

    2017-09-15

    We report the case of a 32 year-old male with Chondroblastic Osteosarcoma of the skull, which was imaged with both {sup 18}[F]fluorodeoxyglucose ({sup 18}F-FDG) positron emission tomography/computed tomography (PET/CT) and {sup 68}Gallium-arginine-glycine-aspartic acid ({sup 68}Ga-RGD) PET/CT. The {sup 18}F-FDG PET/CT did not demonstrate the tumour, whereas the {sup 68}Ga-RGD PET/CT clearly depicted a left-sided frontal tumour. {sup 68}Ga-RGD PET/CT may be a clinically useful imaging modality for early detection of recurrent osteosarcoma, considering the limitations of {sup 18}F-FDG PET in a setting of low glycolytic activity.

  17. Fluorodeoxyglucose positron emission tomography-computed tomography in evaluation of pelvic and para-aortic nodal involvement in early stage and operable cervical cancer: comparison with surgicopathological findings

    International Nuclear Information System (INIS)

    Bansal, Vandana; Damania, Kaizad; Sharma, Anshu Rajnish

    2011-01-01

    Nodal metastases in cervical cancer have prognostic implications. Imaging is used as an adjunct to clinical staging for evaluation of nodal metastases. Fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) has an advantage of superior resolution of its CT component and detecting nodal disease based on increased glycolytic activity rather than node size. But there are limited studies describing its limitations in early stage cervical cancers. We have done meta-analysis with an objective to evaluate the efficacy of FDG PET/CT and its current clinical role in early stage and operable cervical cancer. Studies in which FDG PET/CT was performed before surgery in patients with early stage cervical cancers were included for analysis. PET findings were confirmed with histopathological diagnosis rather than clinical follow-up. The current data suggest that FDG PET/CT is suboptimal in nodal staging in early stage cervical cancer

  18. Additional benefit of 18F-fluorodeoxyglucose integrated positron emission tomography/computed tomography in the staging of oesophageal cancer

    International Nuclear Information System (INIS)

    Gillies, R.S.; Middleton, M.R.; Maynard, N.D.; Bradley, K.M.; Gleeson, F.V.

    2011-01-01

    18 F-fluorodeoxyglucose positron emission tomography (FDG PET) has been shown to improve the accuracy of staging in oesophageal cancer. We assessed the benefit of PET/CT over conventional staging and determined if tumour histology had any significant impact on PET/CT findings. A retrospective cohort study, reviewing the results from 200 consecutive patients considered suitable for radical treatment, undergoing routine PET/CT staging comparing the results from CT and endoscopic ultrasound, as well as multi-disciplinary team records. Adenocarcinoma and squamous cell carcinoma were compared for maximum Standardised Uptake Value (SUV max ), involvement of local lymph nodes and distant metastases. PET/CT provided additional information in 37 patients (18.5%) and directly altered management in 34 (17%): 22 (11%) were upstaged; 15 (7.5%) were downstaged, 12 of whom (6%) received radical treatment. There were 11 false negatives (5.5%) and 1 false positive (0.5%). SUV max was significantly lower for adenocarcinoma than squamous cell carcinoma (median 9.1 versus 13.5, p = 0.003). Staging with PET/CT offers additional benefit over conventional imaging and should form part of routine staging for oesophageal cancer. Adenocarcinoma and squamous cell carcinoma display significantly different FDG-avidity. (orig.)

  19. Role of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography in diagnosis and management of pancreatic cancer; comparison with multidetector row computed tomography, magnetic resonance imaging and endoscopic ultrasonography.

    Science.gov (United States)

    Ergul, N; Gundogan, C; Tozlu, M; Toprak, H; Kadıoglu, H; Aydin, M; Cermik, T F

    2014-01-01

    We aimed to analyze the contribution of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) imaging to the diagnosis and management of pancreatic cancer compared with multidetector row computed tomography (MDCT), magnetic resonance imaging (MRI) and endoscopic ultrasonography (EUS). We retrospectively scanned the data of 52 patients who were referred for FDG PET/CT imaging for evaluation of pancreatic lesions greater than 10mm. The diagnostic performances of 4 imaging methods and the impact of PET/CT on the management of pancreatic cancer were defined. Pancreatic adenocarcinoma was diagnosed in 33 of 52 patients (63%), 15 patients had benign diseases of pancreas (29%), and 4 patients were normal (8%). Sensitivity and NPV of EUS and PET/CT were equal (100%) and higher than MDCT and MRI. Specificity, PPV and NPV of PET/CT were significantly higher than MDCT. However, sensitivities of two imaging methods were not significantly different. There was no significant difference between PET/CT and MRI and EUS for these values. When the cut-off value of SUVmax was 3.2, the most effective sensitivity and specificity values were obtained. PET/CT contributed to the management of pancreatic cancer in 30% of patients. FDG PET/CT is a valuable imaging method for the diagnosis and management of pancreatic cancer, especially when applied along with EUS as first line diagnostic tools. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  20. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  2. Tomography by positrons emission

    International Nuclear Information System (INIS)

    Mosconi, Sergio L.

    1999-01-01

    The tomography by positrons emission is a technology that allows to measure the concentration of positrons emission in a tri dimensional body through external measurements. Among the isotope emissions have carbon isotopes are ( 11 C), of the oxygen ( 15 O), of the nitrogen ( 13 N) that are three the element that constitute the base of the organic chemistry. Theses have on of the PET's most important advantages, since many biological interesting organic molecules can be tracer with these isotopes for the metabolism studies 'in vivo' through PET, without using organic tracers that modify the metabolism. The mentioned isotopes, also possess the characteristic of having short lifetime, that constitute on of PET's advantages from the dosimetric point of view. Among 11 C, 15 O, and 13 N, other isotopes that can be obtained of a generator as the 68 Ga and 82 Rb

  3. Prospective evaluation of fluorodeoxyglucose positron emission tomography/computed tomography scan (FDG-PET/CT) for axillary staging in breast cancer

    International Nuclear Information System (INIS)

    Yamaguchi, Masahide; Noguchi, Akinori; Tani, Naoki

    2008-01-01

    Seventy-two patients from 2005 October to 2007 February with operative breast cancer underwent fluorodeoxyglucose positron emission tomography/computed tomography scan (FDG-PET/CT) of chest and body, ultrasound scan (US) and enhanced computed tomography scan (CT) followed by sentinel lymph node biopsy (SLNB) and axillary lymph node dissection (ALND). The results of PET/CT were compared with histopathological diagnosis of SLNB and ALND. Sensitivity, specificity and accuracy of PET/CT for detection of axillary lymph node metastases were 61%, 96% and 88%, respectively. Seven false-negative and two false-positive of PET/CT results were found. In patients with false-negative of PET/CT results there are two skin-invasive breast cancer patients and axillary lymph node metastases were detected in three patients with US, in one with CT and in four with SLNB. In clinical method for diagnosis of axillary lymph node metastases SLNB should be recommended because sensitivity of PET/CT for early breast cancer patients were low and positive diagnosis of axillary lymph node metastases with PET needs more than 1 cm size of lesion. PET/CT is useful for not-early breast cancer patients. To decide the operation of axillary lymph node disection needs total diagnosis of US, CT, SLNB and clinical findings. (author)

  4. Computed tomography in dementia of Alzheimer type; Comparative study in each stage and comparison to single photon emission computed tomography with N-isopropyl-p-( sup 123 I) iodoamphetamine

    Energy Technology Data Exchange (ETDEWEB)

    Tsunoda, Masahiko; Fujii, Tsutomu; Tanii, Yasuyuki [Toyama Medical and Pharmaceutical Univ., Toyama (Japan); and others

    1990-05-01

    Computed tomography (CT) examinations of 7 patients with dementia of Alzheimer type were reviewed and correlated with clinical stages. The findings of CT were also compared with those of single photon emission computed tomography (SPECT). There was no positive correlation between the degree of cerebral atrophy on CT and clinical stage. Cerebral atrophy seemed to be influenced by aging, ill duration, and the degree of dementia. The cerebral/cerebellar uptake ratio of RI on SPECT was significantly decreased with the progression of clinical stage. SPECT seemed to reflect the degree of dementia, irrespective of ages and ill duration. (N.K.).

  5. Dystrophic calcification in muscles of legs in calcinosis, Raynaud's phenomenon, esophageal dysmotility, sclerodactyly, and telangiectasia syndrome: Accurate evaluation of the extent with 99mTc-methylene diphosphonate single photon emission computed tomography/computed tomography

    International Nuclear Information System (INIS)

    Chakraborty, Partha Sarathi; Karunanithi, Sellam; Dhull, Varun Singh; Kumar, Kunal; Tripathi, Madhavi

    2015-01-01

    We present the case of a 35-year-old man with calcinosis, Raynaud's phenomenon, esophageal dysmotility, sclerodactyly and telangiectasia variant scleroderma who presented with dysphagia, Raynaud's phenomenon and calf pain. 99m Tc-methylene diphosphonate bone scintigraphy was performed to identify the extent of the calcification. It revealed extensive dystrophic calcification in the left thigh and bilateral legs which was involving the muscles and was well-delineated on single photon emission computed tomography/computed tomography. Calcinosis in scleroderma usually involves the skin but can be found in deeper periarticular tissues. Myopathy is associated with a poor prognosis

  6. The clinical usefulness of 18F-fluorodeoxyglucose positron emission tomography-computed tomography (PET-CT) in follow-up of curatively resected pancreatic cancer patients.

    Science.gov (United States)

    Jung, Woohyun; Jang, Jin-Young; Kang, Mee Joo; Chang, Ye Rim; Shin, Yong Chan; Chang, Jihoon; Kim, Sun-Whe

    2016-01-01

    Computed tomography and serum tumor markers have limited value in detecting recurrence after curative surgery of pancreatic cancer. This study evaluated the clinical utility of 18F-fluorodeoxyglucose positron emission tomography-computed tomography (PET-CT) in diagnosing recurrence. One hundred ten patients underwent curative resection of pancreatic cancer were enrolled. The diagnostic value of abdominal computed tomography (CT), PET-CT and serum carbohydrate antigen (CA) 19-9 concentration were compared. The prognostic value of SUVmax on PET-CT was evaluated. PET-CT showed relatively higher sensitivity (84.5% vs. 75.0%) and accuracy (84.5% vs. 74.5%) than CT, whereas PET-CT plus CT showed greater sensitivity (97.6%) and accuracy (90.0%) than either alone. In detecting distant recurrences, PET-CT showed higher sensitivity (83.1% vs. 67.7%) than CT. Nineteen patients showed recurrences only on PET-CT, with eleven having invisible or suspected benign lesions on CT, and eight had recurrences in areas not covered by CT. SUVmax over 3.3 was predictive of poor survival after recurrence. PET-CT in combination with CT improves the detection of recurrence. PET-CT was especially advantageous in detecting recurrences in areas not covered by CT. If active post-operative surveillance after curative resection of pancreatic cancer is deemed beneficial, then it should include PET-CT combined with CT. Copyright © 2015 International Hepato-Pancreato-Biliary Association Inc. Published by Elsevier Ltd. All rights reserved.

  7. Primary pulmonary lymphoma-role of fluoro-deoxy-glucose positron emission tomography-computed tomography in the initial staging and evaluating response to treatment - case reports and review of literature

    International Nuclear Information System (INIS)

    Agarwal, Krishan Kant; Dhanapathi, Halanaik; Nazar, Aftab Hasan; Kumar, Rakesh

    2016-01-01

    Primary pulmonary lymphoma (PPL) is an uncommon entity of non-Hodgkin lymphoma, which accounts for <1% of all cases of lymphoma. We present two rare cases of PPL of diffuse large B-cell lymphoma, which underwent 18 fluorine fluoro-deoxy-glucose positron emission tomography-computed tomography for initial staging and response evaluation after chemotherapy

  8. Impact of 18-fluorodeoxyglucose positron emission tomography on computed tomography defined target volumes in radiation treatment planning of esophageal cancer : reduction in geographic misses with equal inter-observer variability

    NARCIS (Netherlands)

    Schreurs, Liesbeth; Busz, D. M.; Paardekooper, G. M. R. M.; Beukema, J. C.; Jager, P. L.; Van der Jagt, E. J.; van Dam, G. M.; Groen, H.; Plukker, J. Th. M.; Langendijk, J. A.

    P>Target volume definition in modern radiotherapy is based on planning computed tomography (CT). So far, 18-fluorodeoxyglucose positron emission tomography (FDG-PET) has not been included in planning modality in volume definition of esophageal cancer. This study evaluates fusion of FDG-PET and CT in

  9. Computer tomography in otolaryngology

    International Nuclear Information System (INIS)

    Gradzki, J.

    1981-01-01

    The principles of design and the action of computer tomography which was applied also for the diagnosis of nose, ear and throat diseases are discussed. Computer tomography makes possible visualization of the structures of the nose, nasal sinuses and facial skeleton in transverse and eoronal planes. The method enables an accurate evaluation of the position and size of neoplasms in these regions and differentiation of inflammatory exudates against malignant masses. In otology computer tomography is used particularly in the diagnosis of pontocerebellar angle tumours and otogenic brain abscesses. Computer tomography of the larynx and pharynx provides new diagnostic data owing to the possibility of obtaining transverse sections and visualization of cartilage. Computer tomograms of some cases are presented. (author)

  10. Comparison of Positron Emission Tomography Quantification Using Magnetic Resonance- and Computed Tomography-Based Attenuation Correction in Physiological Tissues and Lesions: A Whole-Body Positron Emission Tomography/Magnetic Resonance Study in 66 Patients.

    Science.gov (United States)

    Seith, Ferdinand; Gatidis, Sergios; Schmidt, Holger; Bezrukov, Ilja; la Fougère, Christian; Nikolaou, Konstantin; Pfannenberg, Christina; Schwenzer, Nina

    2016-01-01

    Attenuation correction (AC) in fully integrated positron emission tomography (PET)/magnetic resonance (MR) systems plays a key role for the quantification of tracer uptake. The aim of this prospective study was to assess the accuracy of standardized uptake value (SUV) quantification using MR-based AC in direct comparison with computed tomography (CT)-based AC of the same PET data set on a large patient population. Sixty-six patients (22 female; mean [SD], 61 [11] years) were examined by means of combined PET/CT and PET/MR (11C-choline, 18F-FDG, or 68Ga-DOTATATE) subsequently. Positron emission tomography images from PET/MR examinations were corrected with MR-derived AC based on tissue segmentation (PET(MR)). The same PET data were corrected using CT-based attenuation maps (μ-maps) derived from PET/CT after nonrigid registration of the CT to the MR-based μ-map (PET(MRCT)). Positron emission tomography SUVs were quantified placing regions of interest or volumes of interest in 6 different body regions as well as PET-avid lesions, respectively. The relative differences of quantitative PET values when using MR-based AC versus CT-based AC were varying depending on the organs and body regions assessed. In detail, the mean (SD) relative differences of PET SUVs were as follows: -7.8% (11.5%), blood pool; -3.6% (5.8%), spleen; -4.4% (5.6%)/-4.1% (6.2%), liver; -0.6% (5.0%), muscle; -1.3% (6.3%), fat; -40.0% (18.7%), bone; 1.6% (4.4%), liver lesions; -6.2% (6.8%), bone lesions; and -1.9% (6.2%), soft tissue lesions. In 10 liver lesions, distinct overestimations greater than 5% were found (up to 10%). In addition, overestimations were found in 2 bone lesions and 1 soft tissue lesion adjacent to the lung (up to 28.0%). Results obtained using different PET tracers show that MR-based AC is accurate in most tissue types, with SUV deviations generally of less than 10%. In bone, however, underestimations can be pronounced, potentially leading to inaccurate SUV quantifications. In

  11. Positron Emission Tomography (PET)

    International Nuclear Information System (INIS)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs

  12. Positron Emission Tomography (PET)

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs.

  13. Positron Emission Tomography (PET)

    Science.gov (United States)

    Welch, M. J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET.

  14. Positron emission tomography

    CERN Document Server

    Paans, A M J

    2006-01-01

    Positron Emission Tomography (PET) is a method for measuring biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides such as 11C, 13N, 15O and 18F and by measuring the annihilation radiation using a coincidence technique. This includes also the measurement of the pharmacokinetics of labelled drugs and the measurement of the effects of drugs on metabolism. Also deviations of normal metabolism can be measured and insight into biological processes responsible for diseases can be obtained. At present the combined PET/CT scanner is the most frequently used scanner for whole-body scanning in the field of oncology.

  15. Three-Dimensional Image Fusion of 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography and Contrast-Enhanced Computed Tomography for Computer-Assisted Planning of Maxillectomy of Recurrent Maxillary Squamous Cell Carcinoma and Defect Reconstruction.

    Science.gov (United States)

    Yu, Yao; Zhang, Wen-Bo; Liu, Xiao-Jing; Guo, Chuan-Bin; Yu, Guang-Yan; Peng, Xin

    2017-06-01

    The purpose of this study was to describe new technology assisted by 3-dimensional (3D) image fusion of 18 F-fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) and contrast-enhanced CT (CECT) for computer planning of a maxillectomy of recurrent maxillary squamous cell carcinoma and defect reconstruction. Treatment of recurrent maxillary squamous cell carcinoma usually includes tumor resection and free flap reconstruction. FDG-PET/CT provided images of regions of abnormal glucose uptake and thus showed metabolic tumor volume to guide tumor resection. CECT data were used to create 3D reconstructed images of vessels to show the vascular diameters and locations, so that the most suitable vein and artery could be selected during anastomosis of the free flap. The data from preoperative maxillofacial CECT scans and FDG-PET/CT imaging were imported into the navigation system (iPlan 3.0; Brainlab, Feldkirchen, Germany). Three-dimensional image fusion between FDG-PET/CT and CECT was accomplished using Brainlab software according to the position of the 2 skulls simulated in the CECT image and PET/CT image, respectively. After verification of the image fusion accuracy, the 3D reconstruction images of the metabolic tumor, vessels, and other critical structures could be visualized within the same coordinate system. These sagittal, coronal, axial, and 3D reconstruction images were used to determine the virtual osteotomy sites and reconstruction plan, which was provided to the surgeon and used for surgical navigation. The average shift of the 3D image fusion between FDG-PET/CT and CECT was less than 1 mm. This technique, by clearly showing the metabolic tumor volume and the most suitable vessels for anastomosis, facilitated resection and reconstruction of recurrent maxillary squamous cell carcinoma. We used 3D image fusion of FDG-PET/CT and CECT to successfully accomplish resection and reconstruction of recurrent maxillary squamous cell carcinoma

  16. Regional cerebral blood flow in patients with sickle cell disease: study with single photon emission computed tomography

    International Nuclear Information System (INIS)

    Al-Kandari, F.A.; Owunwanne, A.; Syed, G.M.; Elgazzar, A.H.; Rizui, A.M.; Al-Ajmi, J.A.; Mohammed, A.M.; Ar Marouf, R.; Shiekh, M.

    2007-01-01

    Neurological complications have been reported in patients with sickle-cell disease (SCD) using positron emission tomography (PET), magnetic resonance imaging (MRI), and computed tomography (CT), but not with single photon emission computed tomography (SPECT). The objective of this study was to investigate brain perfusion in the patients with SCD using SPECT after technetium-99m hexamethylpropylene amine oxime ( 99m Tc-HMPAO), was administered and compare the findings with those of demography, physical examination, MRI and hematological profile. The study involved 21 patients (12 males, 9 females, age at study 8-45 years) who were known to be having SCD for a duration of at least 5 years. The patients were not in acute crisis and had normal neurological assessments with no known history of stroke or transient ischemic episode or previous abnormal CT or MRI brain scan, and were right-handed. The brain SPECT was performed after intravenous injection of 740 MBq (20 mCi) 99m Tc-HMPAO in adults or an appropriate dose in pediatric patients. The scans were visually interpreted by two nuclear medicine physicians and a decision was reached by consensus. An MRI done 3 months later was interpreted by a radiologist. The demographic data and hematological profile were obtained from the medical records of the patients. Of the 21 patients, 7 (age 11-22 years) had brain perfusion deficit mostly in the frontal lobe either alone or in combination with temporal and/or parietal lobe. The MRI was abnormal in 2 patients. The brain perfusion deficit was not associated with the demographic data of the patients or hematological profiles. The findings show that SPECT was useful in detecting brain perfusion deficit in SCD patients, and such an early detection may be clinically useful in the subsequent follow-up of such patients, since it is known that cerebral perfusion deficit can lead to silent infarct and/or overt stroke, and affect cognitive skills. (author)

  17. The use of filtering methods to compensate for constant attenuation in single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Gullberg, G.T.; Budinger, T.F.

    1981-01-01

    A back projection of filtered projection (BKFIL) reconstruction algorithm is presented that is applicable to single-photon emission computed tomography (ECT) in the presence of a constant attenuating medium such as the brain. The filters used in transmission computed tomography (TCT)-comprised of a ramp multiplied by window functions-are modified so that the single-photon ECT filter is a function of the constant attenuation coefficient. The filters give good reconstruction results with sufficient angular and lateral sampling. With continuous samples the BKFIL algorithm has a point spread function that is the Hankel transform of the window function. The resolution and statistical properties of the filters are demonstrated by various simulations which assume an ideal detector response. Statistical formulas for the reconstructed image show that the square of the percent-root-mean-square (percent-rms) uncertainty of the reconstruction is inversely proportional to the total measured counts. The results indicate that constant attenuation can be compensated for by using an attenuation-dependent filter that reconstructs the transverse section reliably. Computer time requirements are two times that of conventional TCT or positron ECT and there is no increase in memory requirements

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... of the Sinuses? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... white on the x-ray; soft tissue, such as organs like the heart or liver, shows up ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info About Us News Physician Resources Professions Site Index A-Z Computed Tomography ( ...

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, air-filled spaces within the bones of the face surrounding the ...

  7. Single photon emission computed tomography (SPECT): Clinical routine diagnosis of cerebral malfunction

    International Nuclear Information System (INIS)

    Neidl, K.F.W.

    1993-01-01

    Positron emission tomography is the gold standard for in vivo research in neurophysiology and pathology. The introduction of SPECT and the development of such tracers as 99m Tc-HMPAYO ( 99m Tc-d,l-hexamethylpropylenaminoxim) and, more recently, 123 I-iomazenil and 123 I-IBZM ( 123 I-3-iodo-6-methoxybenzamide) allowed closer examination of the perfusion of the brain and neuroreceptor density mapping in more than the few institutions that can afford PET and the production of special tracers marked with a positron emitting nucleus. Nuclear medicine's future will be based on neuroreceptor density mapping, as further tracers will become commercially available and no other technique can probably show such low concentrations of the receptors. Probably MR techniques will be used for brain's perfusion measurement in future. For examination of a limited cerebral region xenon-enhanced CT is an alternative to perfusion measurements with HMPAO, or a very interesting supplement. Of the old techniques in nuclear medicine, examination of the liquor dynamics is still feasible and well supplemented by SPECT. (orig./MG) [de

  8. Positron emission tomography. Positronemisionstomografi

    Energy Technology Data Exchange (ETDEWEB)

    Bolwig, T G; Haunsoe, S; Dahlgaard Hove, J; Hesse, B; Hoejgard, L; Jensen, M; Paulson, O B; Hastrup Svendsen, J; Soelvsten Soerensen, S

    1994-10-01

    Positron emission tomography (PET) is a method for quantitative imaging of regional physiological and biochemical parameters. Positron emitting radioactive isotopes can be produced by a cyclotron, eg. the biologically important carbon ([sup 11]C), oxygen ([sup 15]O), and nitrogen ([sup 13]N) elements. With the tomographic principles of the PET scanner the quantitative distribution of the administered isotopes can be determined and images can be provided as well as dynamic information on blood flow, metabolism and receptor function. In neurology PET has been used for investigations on numerous physiological processes in the brain: circulation, metabolism and receptor studies. In Parkinson's disease PET studies have been able to localize the pathology specifically, and in early stroke PET technique can outline focal areas with living but non-functioning cells, and this could make it possible to intervene in this early state. With positron emission tomography a quantitative evaluation of myocardial blood flow, glucose and fatty acid metabolism can be made as well as combined assessments of blood flow and metabolism. Combined studies of blood flow and metabolism can determine whether myocardial segments with abnormal motility consist of necrotic or viable tissue, thereby delineating effects of revascularisation. In the future it will probably be possible to characterize the myocardial receptor status in different cardiac diseases. The PET technique is used in oncology for clinical as well as more basic research on tumor perfusion and metabolism. Further, tumor uptake of positron labelled cytotoxic drugs might predict the clinical benefit of treatment. (au) (19 refs.).

  9. Positron emission tomography

    International Nuclear Information System (INIS)

    Bolwig, T.G.; Haunsoe, S.; Dahlgaard Hove, J.; Hesse, B.; Hoejgard, L.; Jensen, M.; Paulson, O.B.; Hastrup Svendsen, J.; Soelvsten Soerensen, S.

    1994-01-01

    Positron emission tomography (PET) is a method for quantitative imaging of regional physiological and biochemical parameters. Positron emitting radioactive isotopes can be produced by a cyclotron, eg. the biologically important carbon ( 11 C), oxygen ( 15 O), and nitrogen ( 13 N) elements. With the tomographic principles of the PET scanner the quantitative distribution of the administered isotopes can be determined and images can be provided as well as dynamic information on blood flow, metabolism and receptor function. In neurology PET has been used for investigations on numerous physiological processes in the brain: circulation, metabolism and receptor studies. In Parkinson's disease PET studies have been able to localize the pathology specifically, and in early stroke PET technique can outline focal areas with living but non-functioning cells, and this could make it possible to intervene in this early state. With positron emission tomography a quantitative evaluation of myocardial blood flow, glucose and fatty acid metabolism can be made as well as combined assessments of blood flow and metabolism. Combined studies of blood flow and metabolism can determine whether myocardial segments with abnormal motility consist of necrotic or viable tissue, thereby delineating effects of revascularisation. In the future it will probably be possible to characterize the myocardial receptor status in different cardiac diseases. The PET technique is used in oncology for clinical as well as more basic research on tumor perfusion and metabolism. Further, tumor uptake of positron labelled cytotoxic drugs might predict the clinical benefit of treatment. (au) (19 refs.)

  10. Improving the quantitative accuracy of optical-emission computed tomography by incorporating an attenuation correction: application to HIF1 imaging

    Science.gov (United States)

    Kim, E.; Bowsher, J.; Thomas, A. S.; Sakhalkar, H.; Dewhirst, M.; Oldham, M.

    2008-10-01

    Optical computed tomography (optical-CT) and optical-emission computed tomography (optical-ECT) are new techniques for imaging the 3D structure and function (including gene expression) of whole unsectioned tissue samples. This work presents a method of improving the quantitative accuracy of optical-ECT by correcting for the 'self'-attenuation of photons emitted within the sample. The correction is analogous to a method commonly applied in single-photon-emission computed tomography reconstruction. The performance of the correction method was investigated by application to a transparent cylindrical gelatin phantom, containing a known distribution of attenuation (a central ink-doped gelatine core) and a known distribution of fluorescing fibres. Attenuation corrected and uncorrected optical-ECT images were reconstructed on the phantom to enable an evaluation of the effectiveness of the correction. Significant attenuation artefacts were observed in the uncorrected images where the central fibre appeared ~24% less intense due to greater attenuation from the surrounding ink-doped gelatin. This artefact was almost completely removed in the attenuation-corrected image, where the central fibre was within ~4% of the others. The successful phantom test enabled application of attenuation correction to optical-ECT images of an unsectioned human breast xenograft tumour grown subcutaneously on the hind leg of a nude mouse. This tumour cell line had been genetically labelled (pre-implantation) with fluorescent reporter genes such that all viable tumour cells expressed constitutive red fluorescent protein and hypoxia-inducible factor 1 transcription-produced green fluorescent protein. In addition to the fluorescent reporter labelling of gene expression, the tumour microvasculature was labelled by a light-absorbing vasculature contrast agent delivered in vivo by tail-vein injection. Optical-CT transmission images yielded high-resolution 3D images of the absorbing contrast agent, and

  11. Improving the quantitative accuracy of optical-emission computed tomography by incorporating an attenuation correction: application to HIF1 imaging

    International Nuclear Information System (INIS)

    Kim, E; Bowsher, J; Thomas, A S; Sakhalkar, H; Dewhirst, M; Oldham, M

    2008-01-01

    Optical computed tomography (optical-CT) and optical-emission computed tomography (optical-ECT) are new techniques for imaging the 3D structure and function (including gene expression) of whole unsectioned tissue samples. This work presents a method of improving the quantitative accuracy of optical-ECT by correcting for the 'self'-attenuation of photons emitted within the sample. The correction is analogous to a method commonly applied in single-photon-emission computed tomography reconstruction. The performance of the correction method was investigated by application to a transparent cylindrical gelatin phantom, containing a known distribution of attenuation (a central ink-doped gelatine core) and a known distribution of fluorescing fibres. Attenuation corrected and uncorrected optical-ECT images were reconstructed on the phantom to enable an evaluation of the effectiveness of the correction. Significant attenuation artefacts were observed in the uncorrected images where the central fibre appeared ∼24% less intense due to greater attenuation from the surrounding ink-doped gelatin. This artefact was almost completely removed in the attenuation-corrected image, where the central fibre was within ∼4% of the others. The successful phantom test enabled application of attenuation correction to optical-ECT images of an unsectioned human breast xenograft tumour grown subcutaneously on the hind leg of a nude mouse. This tumour cell line had been genetically labelled (pre-implantation) with fluorescent reporter genes such that all viable tumour cells expressed constitutive red fluorescent protein and hypoxia-inducible factor 1 transcription-produced green fluorescent protein. In addition to the fluorescent reporter labelling of gene expression, the tumour microvasculature was labelled by a light-absorbing vasculature contrast agent delivered in vivo by tail-vein injection. Optical-CT transmission images yielded high-resolution 3D images of the absorbing contrast agent

  12. Evaluation of diffuse large B-cell lymphoma patients with 64-slice multidetector computed tomography versus 18FDG positron emission tomography/computed tomography in initial staging and restaging after treatment.

    Science.gov (United States)

    Gómez León, Nieves; Vega, Gema; Rodríguez-Vigil Junco, Beatriz; Suevos Ballesteros, Carlos

    2018-04-25

    To prospectively compare the accuracy in initial staging and end-of-treatment restaging of diffuse large B-cell lymphoma (DLBCL) between 64-slice multidetector computed tomography (64MDCT) and 18FDG positron emission tomography/computed tomography (18FGD PET/CT) with intravenous contrast injection. Randomised and blind controlled clinical multicentric trial that included biopsy-proven DLBCL patients. Seventy-two patients from five different hospitals in the region of Madrid, Spain, were enrolled in the study between January 2012 and June 2015. Thirty-six were randomly allocated to 18FDG PET/TC and the other 36 to 64MDCT for initial staging and end-of-treatment restaging. A nuclear medicine physician and a radiologist independently analysed 18FDG PET/TC images and reached an agreement post-hoc. 64MDCT images were separately evaluated by a different radiologist. Every set of images was compared to the reference standard that included clinical data, complementary tests and follow-up. The study was approved by participating centres' ethics committees and written informed consent was obtained from all the participants. A good agreement was observed between both diagnostic techniques and the reference standard in initial staging [18FDG PET/CT (k=0.5) and 64MDCT (k=0.6)], although only the 18FDG PET/TC showed a good agreement with the reference standard for the end-of-treatment restaging (k=0.7). In DLBCL, both 18FDG PET/TC and 64MDCT have shown good agreement with the reference standard in initial staging. Nevertheless, 18FDG PET/CT has shown to be superior to 64MDCT in end-of-treatment response assessment. Copyright © 2018 Elsevier España, S.L.U. All rights reserved.

  13. Assessment of left ventricular function using 201Tl electrocardiogram-gated myocardial single photon emission computed tomography

    International Nuclear Information System (INIS)

    Nishikubo, Naotsugu; Tamai, Hiroyuki

    2013-01-01

    Advances in computed tomography (CT) technology make it possible to obtain left ventricular wall motion using 3D reconstruction. In this study, we compared the images obtained from CT and 201 Tl electrocardiogram (ECG) gated single photon emission computed tomography (SPECT). In 20 patients with ischemic heart disease, we performed 201 Tl ECG gated SPECT (GE Healthcare Millennium VG) and ECG gated CT (Philips Medical Systems Brilliance iCT) to evaluate of left ventricular wall motion during the resting phase. In SPECT, left ventricular images were reconstructed using quantitative gated SPECT (QGS) software. In CT, the images were reconstructed using Virtual Place (AZE Software). The left ventricle was classified into five regions (anterior, lateral, inferior, septal, and apical). The amplitude of the wall motion was classified into five grades according to AHA classification. The values of the wall motion were separately checked by two radiographers. Assessment of left ventricular function myocardial wall movement using the three-dimensional movie display with ECG gated myocardial SPECT data was in agreement with the evaluation by cardiac CT inspection, and corresponded with wall motion in 88 of all 100 segments. SPECT analysis has the same quantity as that of obtained from CT for evaluation of left ventricular wall motion. (author)

  14. Visual cortex activation recorded by dynamic emission computed tomography of inhaled xenon 133

    DEFF Research Database (Denmark)

    Henriksen, L; Paulson, O B; Lassen, N A

    1981-01-01

    to be well suited for detecting focal ischemia. In the present study its ability to detect focal hyperemia was investigated in 13 normal subjects studied during rest and during visual stimulation. A flickering light "seen' with eyes open and closed, increased blood flow in the visual cortex by 35% and 22......Regional cerebral blood flow (CBF) was studied tomographically with 133Xe administered by inhalation over a 1-min period at a concentration of 10 mCi/l. A fast rotating ("dynamic') single-photon emission computed tomograph with four detector heads was used, an instrument that has been found......% respectively. Looking at different pictures displayed on a screen raised regional CBF by 26%. The most complex task, reading and copying a text, increased blood flow by 45%. Averaging the different tasks resulted in a mean regional CBF increase in the visual cortex of 35%. The result is comparable...

  15. Outcomes of Modestly Hypofractionated Radiation for Lung Tumors: Pre- and Mid-Treatment Positron Emission Tomography-Computed Tomography Metrics as Prognostic Factors.

    Science.gov (United States)

    Harris, Jeremy P; Chang-Halpenny, Christine N; Maxim, Peter G; Quon, Andrew; Graves, Edward E; Diehn, Maximilian; Loo, Billy W

    2015-11-01

    Many patients with lung tumors have tumors too large for stereotactic ablative radiotherapy and comorbidities precluding concurrent chemotherapy. We report the outcomes of 29 patients treated with hypofractionated radiotherapy (RT) to 60 to 66 Gy in 3-Gy fractions. We also report an exploratory analysis of the prognostic value of the pre- and mid-RT positron emission tomography-computed tomography. Modestly hypofractionated radiation therapy (HypoRT; 60-66 Gy in 3-Gy fractions) allows patients with locally advanced thoracic tumors and poor performance status to complete treatment within a shorter period without concurrent chemotherapy. We evaluated the outcomes and imaging prognostic factors of HypoRT. We retrospectively reviewed the data from all patients with primary and metastatic intrathoracic tumors treated with HypoRT from 2006 to 2012. We analyzed the survival and toxicity outcomes, including overall survival (OS), progression-free survival (PFS), local recurrence (LR), and distant metastasis. We also evaluated the following tumor metrics in an exploratory analysis: gross tumor volume (GTV), maximum standardized uptake value (SUVMax), and metabolic tumor volume using a threshold of ≥ 50% of the SUVMax (MTV50%) or the maximum gradient of fluorine-18 fluorodeoxyglucose uptake (MTVEdge). We assessed the association of these metrics and their changes from before to mid-RT using positron emission tomography-computed tomography (PET-CT) with OS and PFS. We identified 29 patients, all with pre-RT and 20 with mid-RT PET-CT scans. The median follow-up period was 15 months. The 2-year overall and non-small-cell lung cancer-only rate for OS, PFS, and LR, was 59% and 59%, 52% and 41%, and 27% and 32%, respectively. No grade ≥ 3 toxicities developed. The median decrease in GTV, SUVMax, and MTVEdge was 11%, 24%, and 18%, respectively. Inferior OS was associated with a larger pre-RT MTVEdge (P = .005) and pre-RT MTV50% (P = .007). Inferior PFS was associated with a

  16. Geometrical differences in target volumes based on 18F-fluorodeoxyglucose positron emission tomography/computed tomography and four-dimensional computed tomography maximum intensity projection images of primary thoracic esophageal cancer.

    Science.gov (United States)

    Guo, Y; Li, J; Wang, W; Zhang, Y; Wang, J; Duan, Y; Shang, D; Fu, Z

    2014-01-01

    The objective of the study was to compare geometrical differences of target volumes based on four-dimensional computed tomography (4DCT) maximum intensity projection (MIP) and 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) images of primary thoracic esophageal cancer for radiation treatment. Twenty-one patients with thoracic esophageal cancer sequentially underwent contrast-enhanced three-dimensional computed tomography (3DCT), 4DCT, and 18F-FDG PET/CT thoracic simulation scans during normal free breathing. The internal gross target volume defined as IGTVMIP was obtained by contouring on MIP images. The gross target volumes based on PET/CT images (GTVPET ) were determined with nine different standardized uptake value (SUV) thresholds and manual contouring: SUV≥2.0, 2.5, 3.0, 3.5 (SUVn); ≥20%, 25%, 30%, 35%, 40% of the maximum (percentages of SUVmax, SUVn%). The differences in volume ratio (VR), conformity index (CI), and degree of inclusion (DI) between IGTVMIP and GTVPET were investigated. The mean centroid distance between GTVPET and IGTVMIP ranged from 4.98 mm to 6.53 mm. The VR ranged from 0.37 to 1.34, being significantly (P<0.05) closest to 1 at SUV2.5 (0.94), SUV20% (1.07), or manual contouring (1.10). The mean CI ranged from 0.34 to 0.58, being significantly closest to 1 (P<0.05) at SUV2.0 (0.55), SUV2.5 (0.56), SUV20% (0.56), SUV25% (0.53), or manual contouring (0.58). The mean DI of GTVPET in IGTVMIP ranged from 0.61 to 0.91, and the mean DI of IGTVMIP in GTVPET ranged from 0.34 to 0.86. The SUV threshold setting of SUV2.5, SUV20% or manual contouring yields the best tumor VR and CI with internal-gross target volume contoured on MIP of 4DCT dataset, but 3DPET/CT and 4DCT MIP could not replace each other for motion encompassing target volume delineation for radiation treatment. © 2014 International Society for Diseases of the Esophagus.

  17. [(18)F]Fluorodeoxyglucose - positron emission tomography/computed tomography improves staging in patients with high-risk muscle-invasive bladder cancer scheduled for radical cystectomy.

    Science.gov (United States)

    Kollberg, Petter; Almquist, Helen; Bläckberg, Mats; Cronberg, Carin; Garpered, Sabine; Gudjonsson, Sigurdur; Kleist, Jakob; Lyttkens, Kerstin; Patschan, Oliver; Liedberg, Fredrik

    2015-01-01

    The aim of this study was to evaluate the clinical use of [(18)F]fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) in addition to conventional preoperative radiological investigations in a defined group of patients with high-risk muscle-invasive bladder cancer. In total, 103 patients with high-risk muscle-invasive bladder cancer defined as stage T3/T4 disease or as stage T2 with hydronephrosis or high-risk histological features, who were provisionally scheduled to undergo cystectomy, were prospectively recruited to the study. The patients were referred to FDG-PET/CT in addition to standard preoperative investigation with computed tomography (CT). The final treatment decision was reached at a multidisciplinary conference based on all available information including the FDG-PET/CT findings. Compared to CT alone, FDG-PET/CT provided more supplemental findings suggesting malignant manifestations in 48 (47%) of the 103 patients. The additional FDG-PET/CT findings led to an altered provisional treatment plan in 28 out of 103 patients (27%), detection of disseminated bladder cancer and subsequent cancellation of the initially intended cystectomy in 16 patients, and identification of disseminated disease and treatment with induction chemotherapy before radical cystectomy in 12 patients. Preoperative FDG-PET/CT changed the treatment plan for a considerable proportion (27%) of the present patients. Accordingly, such examination can potentially improve the preoperative staging of cystectomy patients with high-risk features, and may also reduce the number of futile operations in patients with advanced disease who are beyond cure.

  18. Diagnostic performance of fluorodeoxyglucose-positron emission tomography/computed tomography of breast cancer in detecting axillary lymph node metastasis. Comparison with ultrasonography and contrast-enhanced CT

    International Nuclear Information System (INIS)

    Monzawa, Shuichi; Adachi, Shuji; Suzuki, Kayo; Hirokaga, Koichi; Takao, Shintaro; Sakuma, Toshiko; Hanioka, Keisuke

    2009-01-01

    The purpose of this retrospective study was to evaluate the diagnostic performance of positron emission tomography/computed tomography (PET/CT) with fluorine-18-labeled 2-fluoro-2-deoxy-D-glucose (FDG) in comparison with that of ultrasonography and contrast-enhanced computed tomography (CT) in detecting axillary lymph node metastasis in patients with breast cancer. Fifty patients with invasive breast cancer were recruited. They had received no neoadjuvant chemotherapy and underwent PET/CT, ultrasonography and contrast-enhanced CT before mastectomy. The clinical stage was I in 34 patients, II in 15 patients, and III in one patient. The images of these modalities were interpreted in usual practice before surgery and the diagnostic reports were reviewed for analysis. Sensitivity, specificity, positive predictive value, and negative predictive value of each modality were obtained taking histopathological results of axillary lymph node dissection or sentinel lymph node biopsy as the reference standard. Axillary lymph node metastasis was confirmed in 15 of 50 patients by histopathological studies. PET/CT identified lymph node metastasis in three of these 15 patients. The overall sensitivity and specificity, positive predictive value, and negative predictive value of PET/CT in the diagnosis of axillary lymph node metastasis were 20, 97, 75, and 74%, and those of ultrasonography were 33, 94, 71, and 77% and those of contrast-enhanced CT were 27, 97, 80, and 76%, respectively. PET/CT showed poor sensitivity and high specificity in the detection of axillary lymph node metastasis of breast cancer. Diagnostic performance of PET/CT was not superior to that of ultrasonography and contrast-enhanced CT. (author)

  19. Computed tomography of surface related radionuclide distributions ('BONN'-tomography)

    International Nuclear Information System (INIS)

    Bockisch, A.; Koenig, R.

    1989-01-01

    A method called the 'BONN' tomography is described to produce planar projections of circular activity distributions using standard single photon emission computed tomography. The clinical value of the method is demonstrated for bone scans of the jaw, thorax, and pelvis. Numerical or projection-related problems are discussed. (orig.) [de

  20. Positron emission tomography camera

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    A positron emission tomography camera having a plurality of detector planes positioned side-by-side around a patient area to detect radiation. Each plane includes a plurality of photomultiplier tubes and at least two rows of scintillation crystals on each photomultiplier tube extend across to adjacent photomultiplier tubes for detecting radiation from the patient area. Each row of crystals on each photomultiplier tube is offset from the other rows of crystals, and the area of each crystal on each tube in each row is different than the area of the crystals on the tube in other rows for detecting which crystal is actuated and allowing the detector to detect more inter-plane slides. The crystals are offset by an amount equal to the length of the crystal divided by the number of rows. The rows of crystals on opposite sides of the patient may be rotated 90 degrees relative to each other

  1. Positron emission tomography camera

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    A positron emission tomography camera having a plurality of detector rings positioned side-by-side or offset by one-half of the detector cross section around a patient area to detect radiation therefrom. Each ring contains a plurality of scintillation detectors which are positioned around an inner circumference with a septum ring extending inwardly from the inner circumference along each outer edge of each ring. An additional septum ring is positioned in the middle of each ring of detectors and parallel to the other septa rings, whereby the inward extent of all the septa rings may be reduced by one-half and the number of detectors required in each ring is reduced. The additional septa reduces the costs of the positron camera and improves its performance

  2. Positron emission tomography camera

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    A positron emission tomography camera having a plurality of detector rings positioned side-by-side or offset by one-half of the detector cross section around a patient area to detect radiation therefrom. Each detector ring or offset ring includes a plurality of photomultiplier tubes and a plurality of scintillation crystals are positioned relative to the photomultiplier tubes whereby each tube is responsive to more than one crystal. Each alternate crystal in the ring is offset by one-half or less of the thickness of the crystal such that the staggered crystals are seen by more than one photomultiplier tube. This sharing of crystals and photomultiplier tubes allows identification of the staggered crystal and the use of smaller detectors shared by larger photomultiplier tubes thereby requiring less photomultiplier tubes, creating more scanning slices, providing better data sampling, and reducing the cost of the camera. The offset detector ring geometry reduces the costs of the positron camera and improves its performance

  3. Cerebral perfusion inhomogeneities in schizophrenia demonstrated with single photon emission computed tomography and Tc99m-hexamethylpropyleneamineoxim

    International Nuclear Information System (INIS)

    Bajc, M.; Basic, M.; Topuzovic, N.; Babic, C.; Medved, V.

    1989-01-01

    Cerebral blood flow was measured in relative terms with Tc99m-hexamethylpropyleneamineoxim (HMPAO) and single photon emission computed tomography (SPECT) in 28 female schizophrenic patients (20 acute and 8 chronic) classified according to DSM-III. Eleven normals served as controls. The acute patients were classified according to positive and negative symptoms. Patients with predominantly positive symptoms showed by and large normal and homogeneous cerebral isotope uptake. Those with negative symptoms, and the chronic patients, showed inhomogeneous tracer uptake with multiple regions of hypoperfusion in slices 4-6 cm above the orbitomeatal line. The findings support in principle the notion that schizophrenia with negative or chronic symptoms does not affect the whole brain homogeneously. Brain imaging with Tc99m-HMPAO and SPECT might be used to distinguish various types of schizophrenia. (author)

  4. Three-dimensional SPECT [single photon emission computed tomography] reconstruction of combined cone beam and parallel beam data

    International Nuclear Information System (INIS)

    Jaszczak, R.J.; Jianying Li; Huili Wang; Coleman, R.E.

    1992-01-01

    Single photon emission computed tomography (SPECT) using cone beam (CB) collimation exhibits increased sensitivity compared with acquisition geometries using parallel (P) hole collimation. However, CB collimation has a smaller field-of-view which may result in truncated projections and image artifacts. A primary objective of this work is to investigate maximum likelihood-expectation maximization (ML-EM) methods to reconstruct simultaneously acquired parallel and cone beam (P and CB) SPECT data. Simultaneous P and CB acquisition can be performed with commercially available triple camera systems by using two cone-beam collimators and a single parallel-hole collimator. The loss in overall sensitivity (relative to the use of three CB collimators) is about 15 to 20%. The authors have developed three methods to combine P and CB data using modified ML-EM algorithms. (author)

  5. Usefulness of acute myocardial infarct size and localization using Tc-99m-pyrophosphate and single photon emission computed tomography

    International Nuclear Information System (INIS)

    Fujisue, Ryu; Ohyanagi, Mitsumasa; Todo, Yasuhiro

    1985-01-01

    Tc-99m-Pyrophosphate(PYP)myocardial emission computed tomography(ECT) was performed following standard planar imaging in 45 patients(pts) with acute myocardial infarction(AMI). All of them had clinical, electrocardiographic and enzymatic evidence of AMI. The planar imaging and ECT imaging were interpreted independently by two observers who had no knowledge of the clinical findings. 10 pts(22.2 %), who showed diffuse uptake on planar imaging, revealed focal uptake on ECT imaging without cardiac blood pool imaging. And there is no disagreement as to interpretation of the infarct location by two observers on ECT imaging. We conclude that ECT imaging with Tc-99m-PYP increases interobserver agreement in the diagnosis and localization of AMI and may lead to more accurate localization and sizing of AMI, espesically in cases of diffuse cardiac activity on planar imaging. (author)

  6. Evaluation of myocardial and skeletal muscular involvement with thallium-201 myocardial emission computed tomography and whole body scintigraphy

    International Nuclear Information System (INIS)

    Yamamoto, Shuhei; Matsushima, Hideo; Sotobata, Iwao; Suzuki, Akio; Indo, Toshikatsu; Matsuoka, Yukihiko

    1986-01-01

    Thallium-201 (Tl-201) myocardial emission computed tomography and whole body scintigraphy were performed using a rotating gamma camera in 64 patients with neurologic disease and 14 normal subjects. Thallium-201 myocardial perfusion defects were seen in 40 % of the muscular involvement in 47 patients with muscular dystrophy (MD), in whom morphological abnormality of the heart was common. There was strong relationship between the degree of left ventricular perfusion defects and the degree of pulmonary uptake of Tl-201. Thallium-201 whole body scintigraphy showed homogeneous distribution of Tl-201 in the extremities in normal subjects, and perfusion defects in 73 % of the muscular lesions in MD patients. Muscular and skeletal lesions for MD appear to progress independently. Thallium-201 imaging seems to be of clinical value in assessing the muscular and skeletal lesions. (Namekawa, K.)

  7. Recognition of regional hypertrophy in hypertrophic cardiomyopathy using thallium-201 emission-computed tomography: comparison with two-dimensional echocardiography

    International Nuclear Information System (INIS)

    Suzuki, Y.; Kadota, K.; Nohara, R.

    1984-01-01

    The configuration of the hypertrophied myocardium was evaluated by thallium-201 emission-computed tomography and 2-dimensional (2-D) sector scan in 10 patients with obstructive hypertrophic cardiomyopathy (HC), 10 with nonobstructive HC with giant negative T waves and 10 with concentric left ventricular (LV) hypertrophy. Thallium-201 myocardial imaging was reconstructed into multiple 12-mm-thick slices in 3 planes. The thickness ratio of the ventricular septum and the LV posterior wall in the short-axis plane and the ratio of the ventricular septum and the apical wall in the long-axis plane were analyzed. In the patients with obstructive HC the ventricular septal wall thickness index was increased, and the ratio of septal to posterior wall thickness index (1.45 +/- 0.23) was greater than that in the patients with nonobstructive HC with giant negative T waves or in those with concentric LV hypertrophy (1.03 +/- 0.20 and 0.98 +/- 0.11, respectively; p less than 0.01 for each). In the patients with nonobstructive HC with giant negative T waves, increased apical wall thickness with apical cavity obliteration was characteristic, and the ratio of ventricular septal to apical wall thickness index (0.66 +/- 0.14) was less than that in the patients with obstructive HC or in those with concentric LV hypertrophy (1.46 +/- 0.38 and 1.04 +/- 0.09, respectively; p less than 0.001 for each). In contrast, technically satisfactory 2-D sector scanning (83%) demonstrated various configurations of the hypertrophied ventricularseptum, but could not detect apical hypertrophy in 4 of the 10 patients with nonobstructive HC with giant negative T waves whose LV cineangiograms demonstrated apical hypertrophy. Thus, thallium-201 emission-computed tomography is useful in evaluating the characteristics of LV hypertrophy and assists 2-D sector scan, especially in patients with apical hypertrophy in HC

  8. Improved diagnostic performance of exercise thallium-201 single photon emission computed tomography over planar imaging in the diagnosis of coronary artery disease: a receiver operating characteristic analysis

    International Nuclear Information System (INIS)

    Fintel, D.J.; Links, J.M.; Brinker, J.A.; Frank, T.L.; Parker, M.; Becker, L.C.

    1989-01-01

    Qualitative interpretation of tomographic and planar scintigrams, a five point rating scale and receiver operating characteristic analysis were utilized to compare single photon emission computed tomography and conventional planar imaging of myocardial thallium-201 uptake in the accuracy of the diagnosis of coronary artery disease and individual vessel involvement. One hundred twelve patients undergoing cardiac catheterization and 23 normal volunteers performed symptom-limited treadmill exercise, followed by stress and redistribution imaging by both tomographic and planar techniques, with the order determined randomly. Paired receiver operating characteristic curves revealed that single photon emission computed tomography was more accurate than planar imaging over the entire range of decision thresholds for the overall detection and exclusion of coronary artery disease and involvement of the left anterior descending and left circumflex coronary arteries. Tomography offered relatively greater advantages in male patients and in patients with milder forms of coronary artery disease, who had no prior myocardial infarction, only single vessel involvement or no lesion greater than or equal to 50 to 69%. Tomography did not appear to provide improved diagnosis in women or in detection of disease in the right coronary artery. Although overall detection of coronary artery disease was not improved in patients with prior myocardial infarction, tomography provided improved identification of normal and abnormal vascular regions. These results indicate that single photon emission computed tomography provides improved diagnostic performance compared with planar imaging in many clinical subgroups

  9. Computed tomography and three-dimensional imaging

    International Nuclear Information System (INIS)

    Harris, L.D.; Ritman, E.L.; Robb, R.A.

    1987-01-01

    Presented here is a brief introduction to two-, three-, and four-dimensional computed tomography. More detailed descriptions of the mathematics of reconstruction and of CT scanner operation are presented elsewhere. The complementary tomographic imaging methods of single-photon-emission tomography (SPECT) positron-emission tomography (PET), nuclear magnetic resonance (NMR) imaging, ulltrasound sector scanning, and ulltrasound computer-assisted tomography [UCAT] are only named here. Each imaging modality ''probes'' the body with a different energy form, yielding unique and useful information about tomographic sections through the body

  10. (18)F-fluoride positron emission tomography/computed tomography and bone scintigraphy for diagnosis of bone metastases in newly diagnosed, high-risk prostate cancer patients: study protocol for a multicentre, diagnostic test accuracy study.

    Science.gov (United States)

    Fonager, Randi F; Zacho, Helle D; Langkilde, Niels C; Petersen, Lars J

    2016-01-11

    For decades, planar bone scintigraphy has been the standard practice for detection of bone metastases in prostate cancer and has been endorsed by recent oncology/urology guidelines. It is a sensitive method with modest specificity. (18)F-fluoride positron emission tomography/computed tomography has shown improved sensitivity and specificity over bone scintigraphy, but because of methodological issues such as retrospective design and verification bias, the existing level of evidence with (18)F-fluoride positron emission tomography/computed tomography is limited. The primary objective is to compare the diagnostic properties of (18)F-fluoride positron emission tomography/computed tomography versus bone scintigraphy on an individual patient basis. One hundred forty consecutive, high-risk prostate cancer patients will be recruited from several hospitals in Denmark. Sample size was calculated using Hayen's method for diagnostic comparative studies. This study will be conducted in accordance with recommendations of standards for reporting diagnostic accuracy studies. Eligibility criteria comprise the following: 1) biopsy-proven prostate cancer, 2) PSA ≥ 50 ng/ml (equals a prevalence of bone metastasis of ≈ 50% in the study population on bone scintigraphy), 3) patients must be eligible for androgen deprivation therapy, 4) no current or prior cancer (within the past 5 years), 5) ability to comply with imaging procedures, and 6) patients must not receive any investigational drugs. Planar bone scintigraphy and (18)F-fluoride positron emission tomography/computed tomography will be performed within a window of 14 days at baseline. All scans will be repeated after 26 weeks of androgen deprivation therapy, and response of individual lesions will be used for diagnostic classification of the lesions on baseline imaging among responding patients. A response is defined as PSA normalisation or ≥ 80% reduction compared with baseline levels, testosterone below castration levels

  11. Performance of Positron Emission Tomography and Positron Emission Tomography/Computed Tomography Using Fluorine-18-Fluorodeoxyglucose for the Diagnosis, Staging, and Recurrence Assessment of Bone Sarcoma: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Liu, Fengxia; Zhang, Qingyu; Zhu, Dezhi; Li, Zhenfeng; Li, Jianmin; Wang, Boim; Zhou, Dongsheng; Dong, Jinlei

    2015-09-01

    To investigate the performance of fluorine-18-fluorodeoxyglucose (F-FDG) positron emission tomography (PET) and PET/computed tomography (CT) in the diagnosis, staging, restaging, and recurrence surveillance of bone sarcoma by systematically reviewing and meta-analyzing the published literature.To retrieve eligible studies, we searched the MEDLINE, Embase, and the Cochrane Central library databases using combinations of following Keywords: "positron emission tomography" or "PET," and "bone tumor" or "bone sarcoma" or "sarcoma." Bibliographies from relevant articles were also screened manually. Data were extracted and the pooled sensitivity, specificity, and diagnostic odds ratio (DOR), on an examination-based or lesion-based level, were calculated to appraise the diagnostic accuracy of F-FDG PET and PET/CT. All statistical analyses were performed using Meta-Disc 1.4.Forty-two trials were eligible. The pooled sensitivity and specificity of PET/CT to differentiate primary bone sarcomas from benign lesions were 96% (95% confidence interval [CI], 93-98) and 79% (95% CI, 63-90), respectively. For detecting recurrence, the pooled results on an examination-based level were sensitivity 92% (95% CI, 85-97), specificity 93% (95% CI, 88-96), positive likelihood ratio (PLR) 10.26 (95% CI, 5.99-17.60), and negative likelihood ratio (NLR) 0.11 (95% CI, 0.05-0.22). For detecting distant metastasis, the pooled results on a lesion-based level were sensitivity 90% (95% CI, 86-93), specificity 85% (95% CI, 81-87), PLR 5.16 (95% CI, 2.37-11.25), and NLR 0.15 (95% CI, 0.11-0.20). The accuracies of PET/CT for detecting local recurrence, lung metastasis, and bone metastasis were satisfactory. Pooled outcome estimates of F-FDG PET were less complete compared with those of PET/CT.F-FDG PET and PET/CT showed a high sensitivity for diagnosing primary bone sarcoma. Moreover, PET/CT demonstrated excellent accuracy for the staging, restaging, and recurrence surveillance of bone sarcoma. However

  12. Positron emission tomography of malignant tumours at head and neck. Evaluation of the diagnostic value of positron emission tomography by comparison with computed tomography; Positronenemissionstomographie bei malignen Tumoren im Kopf- und Halsbereich. Beurteilung der diagnostischen Wertigkeit der Positronenemissionstomographie im Vergleich zur Computertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Kettler, Nele

    2011-12-02

    Imaging methods for early, accurate diagnosis and aftercare of malignant growths is currently one of the most important research topics. The objective of this thesis is to evaluate the diagnostic value of FDG-positron emission tomography by comparison with computed tomography for patients with squamous cell carcinoma, malignant melanoma or sarcoma at head and neck. Measurement criteria are sensitivity and specificity. A retrospective evaluation of 100 examinations on 85 patients of University clinic Aachen was performed. The examination reports were supported by reports from histology, positron emission tomography and computed tomography. In each case, the histological results were assumed to provide a reliable benchmark. Sensitivity and specificity for the primary tumour site, metastatic lymphatic nodes and defined anatomic structures were compared across all patients. Comparisons were also performed on sub groups separated by gender, cancer type and the time and frequency at which tumours arose. The statistic analysis was done with MedCalc. Results: The results for sensitivity and specificity of the primary tumour site were 86.42% and 42.86%, and 64.71% and 66.07%, for positron emission tomography and computed tomography respectively. The results for the lymphatic nodes were 51.52% and 92.86% and 64.71% and 66.07%. When the constituent anatomic structures were evaluated separately, the specificity was significantly higher. The separation by gender showed no difference. Because the classification by tumor type resulted in samples that were of varying size, a comparison was difficult. For the diagnosis of primary tumours, the examination with positron emission tomography was superior, whereas computed tomography proved more effective for the diagnosis of recurrent tumours. For the diagnosis of the main tumour site, both methods were shown to be equally suitable. For the assessment of lymphatic nodes, positron emission tomography was superior to computed tomography

  13. 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Accuracy in the Staging of Non-Small Cell Lung Cancer: Review and Cost-Effectiveness

    International Nuclear Information System (INIS)

    Gómez León, Nieves; Escalona, Sofía; Bandrés, Beatriz; Belda, Cristobal; Callejo, Daniel; Blasco, Juan Antonio

    2014-01-01

    Aim of the performed clinical study was to compare the accuracy and cost-effectiveness of PET/CT in the staging of non-small cell lung cancer (NSCLC). Material and Methods. Cross-sectional and prospective study including 103 patients with histologically confirmed NSCLC. All patients were examined using PET/CT with intravenous contrast medium. Those with disease stage ≤IIB underwent surgery (n = 40). Disease stage was confirmed based on histology results, which were compared with those of PET/CT and positron emission tomography (PET) and computed tomography (CT) separately. 63 patients classified with ≥IIIA disease stage by PET/CT did not undergo surgery. The cost-effectiveness of PET/CT for disease classification was examined using a decision tree analysis. Results. Compared with histology, the accuracy of PET/CT for disease staging has a positive predictive value of 80%, a negative predictive value of 95%, a sensitivity of 94%, and a specificity of 82%. For PET alone, these values are 53%, 66%, 60%, and 50%, whereas for CT alone they are 68%, 86%, 76%, and 72%, respectively. Incremental cost-effectiveness of PET/CT over CT alone was €17,412 quality-adjusted life-year (QALY). Conclusion. In our clinical study, PET/CT using intravenous contrast medium was an accurate and cost-effective method for staging of patients with NSCLC

  14. Impacts of biological and procedural factors on semiquantification uptake value of liver in fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography imaging.

    Science.gov (United States)

    Mahmud, Mohd Hafizi; Nordin, Abdul Jalil; Ahmad Saad, Fathinul Fikri; Azman, Ahmad Zaid Fattah

    2015-10-01

    Increased metabolic activity of fluorodeoxyglucose (FDG) in tissue is not only resulting of pathological uptake, but due to physiological uptake as well. This study aimed to determine the impacts of biological and procedural factors on FDG uptake of liver in whole body positron emission tomography/computed tomography (PET/CT) imaging. Whole body fluorine-18 ((18)F) FDG PET/CT scans of 51 oncology patients have been reviewed. Maximum standardized uptake value (SUVmax) of lesion-free liver was quantified in each patient. Pearson correlation was performed to determine the association between the factors of age, body mass index (BMI), blood glucose level, FDG dose and incubation period and liver SUVmax. Multivariate regression analysis was established to determine the significant factors that best predicted the liver SUVmax. Then the subjects were dichotomised into four BMI groups. Analysis of variance (ANOVA) was established for mean difference of SUVmax of liver between those BMI groups. BMI and incubation period were significantly associated with liver SUVmax. These factors were accounted for 29.6% of the liver SUVmax variance. Statistically significant differences were observed in the mean SUVmax of liver among those BMI groups (Pvalue for physiological liver SUVmax as a reference standard for different BMI of patients in PET/CT interpretation and use a standard protocol for incubation period of patient to reduce variation in physiological FDG uptake of liver in PET/CT study.

  15. Impact of incidental findings on integrated 2-[18F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography in patients with gastric cancer.

    Science.gov (United States)

    Tae, Chung Hyun; Lee, Jun Haeng; Choi, Joon Young; Min, Byung-Hoon; Rhee, Poong-Lyul; Kim, Jae J

    2015-03-01

    Since positron emission tomography/computed tomography (PET/CT) has been introduced, many incidental findings have been identified. The aim of this study was to assess the clinical significance of incidental findings on PET/CT in patients with gastric cancer. A total of 421 patients with gastric cancer underwent PET/CT for initial staging. Incidental findings on PET/CT were classified into five categories according to clinical significance--normal variant, benign, probably benign, probably malignant, and definitely malignant. We obtained information regarding follow-up examinations, additional visits, final diagnosis of incidental findings and short-term medical costs for further evaluation. Eight hundred eighty-two incidental findings were detected in 386 (91.7%) patients. Of 274 incidental findings classified as probably benign, probably malignant or definitely malignant, 130 required one or more additional investigations. Finally, 12 (9.2%) were proved to be associated with second primary malignancy or metastasis of gastric cancer. One hundred twenty-nine additional outpatient visits and 10 additional hospitalizations were needed for evaluating the incidental findings. The treatment strategy for gastric cancer was changed in one patient. The estimated cost of additional investigations was $US283 (95% CI: $US248-$US311) per patient. Incidental findings on PET/CT were common. Although the incidental findings were suspicious of malignancy, most were benign with high costs for additional investigations. © 2015 Wiley Publishing Asia Pty Ltd.

  16. F-18 Sodium Fluoride Positron Emission Tomography/Computed Tomography for Detection of Thyroid Cancer Bone Metastasis Compared with Bone Scintigraphy.

    Science.gov (United States)

    Lee, Hyunjong; Lee, Won Woo; Park, So Yeon; Kim, Sang Eun

    2016-01-01

    The aim of the study was to compare the diagnostic performances of F-18 sodium fluoride positron emission tomography/computed tomography (bone PET/CT) and bone scintigraphy (BS) for the detection of thyroid cancer bone metastasis. We retrospectively enrolled 6 thyroid cancer patients (age = 44.7 ± 9.8 years, M:F = 1:5, papillary:follicular = 2:4) with suspected bone metastatic lesions in the whole body iodine scintigraphy or BS, who subsequently underwent bone PET/CT. Pathologic diagnosis was conducted for 4 lesions of 4 patients. Of the 17 suspected bone lesions, 10 were metastatic and 7 benign. Compared to BS, bone PET/CT exhibited superior sensitivity (10/10 = 100% vs. 2/10 = 20%, p = 0.008), and accuracy (14/17 = 82.4% vs. 7/17 = 41.2%, p 0.05). Bone PET/CT may be more sensitive and accurate than BS for the detection of thyroid cancer bone metastasis.

  17. Lower maximum standardized uptake value of fluorine-18 fluorodeoxyglucose positron emission tomography coupled with computed tomography imaging in pancreatic ductal adenocarcinoma patients with diabetes.

    Science.gov (United States)

    Chung, Kwang Hyun; Park, Joo Kyung; Lee, Sang Hyub; Hwang, Dae Wook; Cho, Jai Young; Yoon, Yoo-Seok; Han, Ho-Seong; Hwang, Jin-Hyeok

    2015-04-01

    The effects of diabetes mellitus (DM) on sensitivity of fluorine-18 fluorodeoxyglucose positron emission tomography coupled with computed tomography ((18)F-FDG PET/CT) for diagnosing pancreatic ductal adenocarcinomas (PDACs) is not well known. This study was aimed to evaluate the effects of DM on the validity of (18)F-FDG PET/CT in PDAC. A total of 173 patients with PDACs who underwent (18)F-FDG PET/CT were enrolled (75 in the DM group and 98 in the non-DM group). The maximum standardized uptake values (SUVsmax) were compared. The mean SUVmax was significantly lower in the DM group than in the non-DM group (4.403 vs 5.998, P = .001). The sensitivity of SUVmax (cut-off value 4.0) was significantly lower in the DM group than in the non-DM group (49.3% vs 75.5%, P < .001) and also lower in normoglycemic DM patients (n = 24) than in non-DM patients (54.2% vs 75.5%, P = .038). DM contributes to a lower SUVmax of (18)F-FDG PET/CT in patients with PDACs. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Effect of furosemide administration before F-18 fluorodeoxyglucose positron emission tomography/computed tomography on urine radioactivity and detection of uterine cervical cancer.

    Science.gov (United States)

    d'Amico, Andrea; Gorczewska, Izabela; Gorczewski, Kamil; Turska-d'Amico, Maria; Di Pietro, Marco

    2014-01-01

    In evaluating uterine cervical cancer with ¹⁸F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT), there may be overlap between the FDG activity at tumor sites and nonspecific radioactivity in the urine. We evaluated the efficacy of furosemide premedication with routine hydration to obtain better contrast and less overlap between cervical cancer and the urinary bladder. We retrospectively evaluated 166 patients who had primary or relapsed cervical cancer and underwent FDG PET/CT scanning with (133 patients) or without (33 patients) furosemide premedication (10 mg intravenous, slowly injected 30 min before the scan). We calculated bladder and tumor maximum and median standardized uptake value (SUVmax and SUVmed), and overlap between tumor and urinary activity was detected visually. Overlap between urinary and tumor radioactivity was observed in 8 of 133 scans (6%) in patients who receive furosemide and in 3 of 33 scans (9%) in patients who did not receive furosemide. The SUVmax and SUVmed for the bladder were significantly lower in patients who were pretreated with furosemide (SUVmax, 6.3; SUVmed, 4.6) than patients who were not pretreated with furosemide (SUVmax, 8.8 [P ≤ 0.008]; SUVmed, 6.5 [P ≤ 0.002]). The tumor SUVmax and SUVmed were similar between the patient groups. Furosemide premedication before FDG PET/CT scanning may enable improved evaluation of activity and extension of cervical cancer.

  19. 18F-fluorodeoxyglucose positron emission tomography/computed tomography for primary thyroid langerhans histiocytosis: A case report and literature review

    International Nuclear Information System (INIS)

    Long, Qi; Shaoyan, Wang; Hui, Wang

    2015-01-01

    Langerhans cell histiocytosis (LCH) is a rare clonal proliferative disease, with an incidence rate of 4.0–5.4/1 million individuals. LCH encompasses a spectrum of disorders with diverse clinical presentations ranging from a single organ to multiple organ involvement. LCH rarely involves the thyroid gland. We presented a case with LCH of thyroid gland. The patient had painless progressive neck enlargement and then diabetes insipidus. Ultrasonic scan and magnetic resonance imaging scan revealed nodular goiter and pituitary stalk enlargement, respectively. Histopathological analysis revealed features of histiocytoid cells. 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) was performed in order to rule out the presence of whole body infiltration. 18F-FDG PET/CT also demonstrated increased uptake in the thickening pituitary stalk and maxillofacial skin lesion, in addition to the bilateral thyroid nodules, CT showed the left lung nodule and the skull destruction without 18F-FDG uptake. This report emphasizes the role of 18F-FDG PET/CT in multiple organs involvement of patients with LCH

  20. F-8 sodium fluoride position emission tomography/computed tomography for detection of thyroid cancer bone metastasis compared with bone scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyun Jong; Lee, Won Woo; Park, So Yeon; Kim, Sang Eun [Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2016-04-15

    The aim of the study was to compare the diagnostic performances of F-18 sodium fluoride positron emission tomography/computed tomography (bone PET/CT) and bone scintigraphy (BS) for the detection of thyroid cancer bone metastasis. We retrospectively enrolled 6 thyroid cancer patients (age = 44.7 ± 9.8 years, M:F = 1:5, papillary:follicular = 2:4) with suspected bone metastatic lesions in the whole body iodine scintigraphy or BS, who subsequently underwent bone PET/CT. Pathologic diagnosis was conducted for 4 lesions of 4 patients. Of the 17 suspected bone lesions, 10 were metastatic and 7 benign. Compared to BS, bone PET/CT exhibited superior sensitivity (10/10 = 100% vs. 2/10 = 20%, p = 0.008), and accuracy (14/17 = 82.4% vs. 7/17 = 41.2%, p < 0.025). The specificity (4/7 = 57.1%) of bone PET/CT was not significantly different from that of BS (5/7 = 71.4%, p > 0.05). Bone PET/CT may be more sensitive and accurate than BS for the detection of thyroid cancer bone metastasis.

  1. 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Accuracy in the Staging of Non-Small Cell Lung Cancer: Review and Cost-Effectiveness

    International Nuclear Information System (INIS)

    Leon, N.G.; Bandrs, B.; Escalona, S.; Callejo, D.; Blasco, J.A.; Belda, C.; Blasco, J.A.

    2014-01-01

    Aim of the performed clinical study was to compare the accuracy and cost-effectiveness of PET/CT in the staging of non-small cell lung cancer (NSCLC). Material and Methods. Cross-sectional and prospective study including 103 patients with histologically confirmed NSCLC. All patients were examined using PET/CT with intravenous contrast medium. Those with disease stage ≤IIB underwent surgery (η=40). Disease stage was confirmed based on histology results, which were compared with those of PET/CT and positron emission tomography (PET) and computed tomography (CT) separately. 63 patients classified with ≥IIIA disease stage by PET/CT did not undergo surgery. The cost-effectiveness of PET/CT for disease classification was examined using a decision tree analysis. Results. Compared with histology, the accuracy of PET/CT for disease staging has a positive predictive value of 80%, a negative predictive value of 95%, a sensitivity of 94%, and a specificity of 82%. For PET alone, these values are 53%, 66%, 60%, and 50%, whereas for CT alone they are 68%, 86%, 76%, and 72%, respectively. Incremental cost-effectiveness of PET/CT over CT alone was €17,412 quality-adjusted life-year (QALY). Conclusion. In our clinical study, PET/CT using intravenous contrast medium was an accurate and cost-effective method for staging of patients with NSCLC

  2. [Prognostic value of (18)F-fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) in extensive-stage small cell lung cancer].

    Science.gov (United States)

    Ding, C Y; Guo, Z; Li, Y Y; Li, T R

    2017-11-23

    Objective: To investigated the prognostic value of (18)F-fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) in extensive-stage small cell lung cancer (ES -SCLC). Methods: Fifty-five patients with ES-SCLC who underwent pretreatment (18)F-FDG PET-CT were retrospectively recruited in this study. The correlations of maximum standardized uptake value (SUVmax) of primary lesion, metabolic tumor volume (MTV) of primary lesion (MTVp), total lesion glycolysis (TLG) of primary lesion (TLGp), the highest SUVmax of all lesions, the sum of metabolic volume (MTV sum), the sum of total lesions glycolysis (TLGsum) and clinical factors were analyzed. Results: The SUVmax, MTVp, TLGp, the highest SUVmax, MTVsum and TLGsum of 55 patients were 11.34±7.02, 29.61 cm(3,) 207.72, 13.61±7.10, 123.57 cm(3) and 988.48, respectively. The SUVmax of primary lesion, MTVp and TLGp were correlated with tumor type and the maximal tumor length, respectively(all P CT has certain prognostic value of patients with ES-SCLC. MTVsum and TLGsum are the independent predictors of PFS, and TLGsum is also an independent predictor of OS.

  3. Positron emission tomography/computed tomography (PET/CT) and CT for N staging of non-small cell lung cancer.

    Science.gov (United States)

    Vegar Zubović, Sandra; Kristić, Spomenka; Hadžihasanović, Besima

    2017-08-01

    Aim The aim of this study is to investigate the possibilities of non-invasive diagnostic imaging methods, positron emission tomography/computed tomography (PET/CT) and CT, in clinical N staging of non-small cell lung cancer (NSCLC). Methods Retrospective clinical study included 50 patients with diagnosed NSCLC who have undergone PET/CT for the purpose of disease staging. The International association for the study of lung cancer (IASLC) nodal mapping system was used for analysis of nodal disease. Data regarding CT N-staging and PET/CT Nstaging were recorded. Two methods were compared using χ2 test and Spearman rank correlation coefficient. Results Statistical analysis showed that although there were some differences in determining the N stage between CT and PET/CT, these methods were in significant correlation. CT and PET/CT findings established the same N stage in 74% of the patients. In five patients based on PET/CT findings the staging was changed from operable to inoperable, while in four patients staging was changed from inoperable to operable. Conclusion PET/CT and CT are noninvasive methods that can be reliably used for N staging of NSCLC. Copyright© by the Medical Assotiation of Zenica-Doboj Canton.

  4. Endogenous endophthalmitis caused by Cryptococcus neoformans Var. Gattii mimicking choroidal tumor: From positron-emission tomography/computed tomography to histopathology

    Directory of Open Access Journals (Sweden)

    Chun-Ju Lin

    2017-01-01

    Full Text Available A 60-year-old immunocompetent female with pneumonia history about 10 years ago suffered from blurred vision overall survival for 3 weeks. Common cold with headache and unintentional body weight loss was also noted recently. Choroidal detachment simulating choroidal tumor was observed in the temporal quadrant. The 18F-fluoro-2-deoxyglucose (FDG positron-emission tomography/computed tomography (CT scan showed focal, mild to moderate FDG uptake in the left lateral orbit, and an enhanced lesion was seen on the recent CT scan. The suspicious choroidal tumor became larger in a week. Phacoemulsification, vitrectomy, and retinal biopsies were performed. Histochemical study of the retinal specimens established the diagnosis of endogenous cryptococcal endophthalmitis. Vitreous culture yielded Cryptococcus neoformans var. gattii. Systemic and topical voriconazole eliminated the infection. In the literature, endogenous endophthalmitis caused by C. neoformans var. gattii has not been reported in detail. The key to successful management lies in early diagnosis. If clinical improvement could not be achieved after conventional management and imaging studies have failed to yield a definite diagnosis, retinal biopsy can be considered.

  5. Incidental detection of prostate-specific antigen-negative metastatic prostate cancer initially presented with solitary pulmonary nodule on fluorodeoxyglucose positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Erdogan, Ezgi Basak; Buyukpinarbasili, Nur; Ziyade, Sedat; Akman, Tolga; Turk, Haci Mehmet; Aydin, Mehmet

    2005-01-01

    A 71-year-old male patient with solitary pulmonary nodule underwent fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) showing slightly increased FDG uptake in this nodule. In addition, PET/CT detected hypermetabolic sclerotic bone lesions in the right second rib and 7 th thoracic vertebrae, which were interpreted as possible metastases, and mildly increased FDG uptake in the prostate gland highly suspicious of malignancy. The patient's prostate-specific antigen (PSA) level was within normal range (3.8 ng/dL). The histopathological examination of the lung nodule and right second rib lesion proved metastases from prostate cancer, then the prostate biopsy-confirmed prostate adenocarcinoma. The unique feature of this case is to emphasize the importance of performing PET/CT for solitary pulmonary nodule in detecting PSA-negative metastatic prostate cancer. This case indicated that it should be kept in mind that, even if the PSA is negative, a lung metastasis of prostate cancer may be an underlying cause in patients evaluated for solitary pulmonary nodule by FDG PET/CT

  6. Metastasis in urothelial carcinoma mimicking prostate cancer metastasis in Ga-68 prostate-specific membrane antigen positron emission tomography-computed tomography in a case of synchronous malignancy

    International Nuclear Information System (INIS)

    Gupta, Manoj; Choudhury, Partha Sarathi; Gupta, Gurudutt; Gandhi, Jatin

    2016-01-01

    Prostate cancer is the second most common cancer in man. It commonly presents with urinary symptoms, bone pain, or diagnosed with elevated prostate-specific antigen.(PSA) levels. Correct staging and early diagnosis of recurrence by a precise imaging tool are the keys for optimum management. Molecular imaging of prostate cancer with Ga-68 prostate-specific membrane antigen.(PSMA), positron emission tomography-computed tomography.(PET-CT) has recently received significant attention and frequently used with a signature to prostate cancer-specific remark. However, this case will highlight the more cautious use of it. A-72-year-old male treated earlier for synchronous double malignancy.(invasive papillary urothelial carcinoma right ureter and carcinoma prostate) presented with rising PSA.(0.51.ng/ml) and referred for Ga-68 PSMA PET-CT, which showed a positive enlarged left supraclavicular lymph node. Lymph node biopsy microscopic and immunohistochemistry examination revealed metastatic carcinoma favoring urothelial origin. Specificity of PSMA scan to prostate cancer has been seen to be compromised in a certain situation mostly due to neoangiogenesis, and false positives emerged in renal cell cancer, differentiated thyroid cancer, glioblastoma, breast cancer brain metastasis, and paravertebral schwannomas. Understanding the causes of false positive will further enhance the confidence of interpretating PSMA scans

  7. IgG4-associated multifocal systemic fibrosis detected by cancer screening with 18F-FDG positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Soga, Shigeyoshi; Kita, Tamotsu; Hiratsuka, Miyuki; Sakaguchi, Chiharu; Shinmoto, Hiroshi; Kosuda, Shigeru; Sakata, Ikuko; Miura, Soichiro

    2010-01-01

    Serial fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) studies were performed with an interval of one year in a 62-year-old man with IgG4-associated multifocal systemic fibrosis (IMSF). He first underwent 18 F-FDG PET/CT cancer screening, which revealed multiple 18 F-FDG-avid uptakes in the pancreas, prostate, and lymph nodes in the upper mediastinum, pulmonary hila, porta hepatis, and the left iliac and inguinal regions. He was not symptomatic at this initial examination. The follow-up 18 F-FDG PET/CT study showed disappearance of 18 F-FDG-avid uptake foci in the pancreas despite no treatment having been administered, but demonstrated new lesions in the abdominal para-aortic region and more intense FDG uptake in the porta hepatis lesion. Serial 18 F-FDG PET/CT studies might be useful in monitoring patients with IMSF, as well as evaluating the state of systemic involvement. Findings of 18 F-FDG PET/CT may provide information useful for determining the optimal initiation of IMSF treatment. (author)

  8. F-18 fluoride positron emission tomography/computed tomography in the diagnosis of avascular necrosis of the femoral head: Comparison with magnetic resonance imaging

    Science.gov (United States)

    Gayana, Shankaramurthy; Bhattacharya, Anish; Sen, Ramesh Kumar; Singh, Paramjeet; Prakash, Mahesh; Mittal, Bhagwant Rai

    2016-01-01

    Objective: Femoral head avascular necrosis (FHAVN) is one of the increasingly common causes of musculoskeletal disability and poses a major diagnostic and therapeutic challenge. Although radiography, scintigraphy, computed tomography (CT), and magnetic resonance imaging (MRI) have been widely used in the diagnosis of FHAVN, positron emission tomography (PET) has recently been evaluated to assess vascularity of the femoral head. In this study, the authors compared F-18 fluoride PET/CT with MRI in the initial diagnosis of FHAVN. Patients and Methods: We prospectively studied 51 consecutive patients with a high clinical suspicion of FHAVN. All patients underwent MRI and F-18 fluoride PET/CT, the time interval between the two scans being 4–10 (mean 8) days. Two nuclear medicine physicians blinded to the MRI report read the PET/CT scans. Clinical assessment was also done. Final diagnoses were made by surgical pathology or clinical and radiologic follow-up. Results: A final diagnosis of avascular necrosis (AVN) was made in 40 patients. MRI was 96.5% sensitive, 100% specific, and 98.03% accurate while PET/CT was 100% sensitive, specific, and accurate in diagnosing FHAVN. The agreement between the two imaging modalities for the diagnosis of AVN was 96.07%. Conclusion: F-18 fluoride PET/CT showed good agreement with MRI in the initial diagnosis of FHAVN and can be better than MRI in detecting early disease. PMID:26917886

  9. F-18 fluoride positron emission tomography/computed tomography in the diagnosis of avascular necrosis of the femoral head: Comparison with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Gayana, Shankaramurthy; Bhattacharya, Anish; Sen, Ramesh Kumar; Singh, Paramjeet; Prakash, Mahesh; Mittal, Bhagwant Rai

    2016-01-01

    Femoral head avascular necrosis (FHAVN) is one of the increasingly common causes of musculoskeletal disability and poses a major diagnostic and therapeutic challenge. Although radiography, scintigraphy, computed tomography (CT), and magnetic resonance imaging (MRI) have been widely used in the diagnosis of FHAVN, positron emission tomography (PET) has recently been evaluated to assess vascularity of the femoral head. In this study, the authors compared F-18 fluoride PET/CT with MRI in the initial diagnosis of FHAVN. We prospectively studied 51 consecutive patients with a high clinical suspicion of FHAVN. All patients underwent MRI and F-18 fluoride PET/CT, the time interval between the two scans being 4–10 (mean 8) days. Two nuclear medicine physicians blinded to the MRI report read the PET/CT scans. Clinical assessment was also done. Final diagnoses were made by surgical pathology or clinical and radiologic follow-up. A final diagnosis of avascular necrosis (AVN) was made in 40 patients. MRI was 96.5% sensitive, 100% specific, and 98.03% accurate while PET/CT was 100% sensitive, specific, and accurate in diagnosing FHAVN. The agreement between the two imaging modalities for the diagnosis of AVN was 96.07%. F-18 fluoride PET/CT showed good agreement with MRI in the initial diagnosis of FHAVN and can be better than MRI in detecting early disease

  10. Predictive value of pretreatment positron emission tomography/computed tomography in patients with newly diagnosed extranodal natural killer/T-cell lymphoma.

    Science.gov (United States)

    Bai, Bing; Huang, Hui-Qiang; Cai, Qi-Chun; Fan, Wei; Wang, Xiao-Xiao; Zhang, Xu; Lin, Ze-Xiao; Gao, Yan; Xia, Yun-Fei; Guo, Ying; Cai, Qing-Qing; Jiang, Wen-Qi; Lin, Tong-Yu

    2013-03-01

    The role of (18)Fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) in extranodal natural killer/T-cell lymphoma (ENKL) is not well established. This study aimed to investigate the prognostic role of the pretreatment maximum standardized uptake value (SUV(max)) on PET/CT in patients with newly diagnosed ENKL. Among 364 consecutive patients with newly diagnosed ENKL, 81 patients were included and reviewed. The impact of SUV(max) on survival and the relationship between SUV(max) and other clinicopathological parameters were analyzed. The median SUV(max) was 14.6 (range 2.0-45.4). The optimal cutoff value of SUV(max) to predict overall survival (OS) was 15. Patients with high SUV(max) (SUVmax >15) were associated with bulky disease (P KPI, P = 0.046), resistance to primary treatment (P = 0.014), poor OS (P 60 years (P = 0.001), stage III-IV (P = 0.023), SUV(max) >15 (P = 0.020), and bulky disease (>5 cm) (P = 0.002). By using the SUV(max), patients in most subgroups stratified by the KPI or the International Prognostic Index (IPI) were further discriminated in OS with significant statistical difference. Our results suggest the pretreatment SUV(max) is predictive of prognosis in patients with newly diagnosed ENKL. The SUV(max) may provide additional prognostic information for IPI and KPI.

  11. [Restoration filtering based on projection power spectrum for single-photon emission computed tomography].

    Science.gov (United States)

    Kubo, N

    1995-04-01

    To improve the quality of single-photon emission computed tomographic (SPECT) images, a restoration filter has been developed. This filter was designed according to practical "least squares filter" theory. It is necessary to know the object power spectrum and the noise power spectrum. The power spectrum is estimated from the power spectrum of a projection, when the high-frequency power spectrum of a projection is adequately approximated as a polynomial exponential expression. A study of the restoration with the filter based on a projection power spectrum was conducted, and compared with that of the "Butterworth" filtering method (cut-off frequency of 0.15 cycles/pixel), and "Wiener" filtering (signal-to-noise power spectrum ratio was a constant). Normalized mean-squared errors (NMSE) of the phantom, two line sources located in a 99mTc filled cylinder, were used. NMSE of the "Butterworth" filter, "Wiener" filter, and filtering based on a power spectrum were 0.77, 0.83, and 0.76 respectively. Clinically, brain SPECT images utilizing this new restoration filter improved the contrast. Thus, this filter may be useful in diagnosis of SPECT images.

  12. Restoration filtering based on projection power spectrum for single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Kubo, Naoki

    1995-01-01

    To improve the quality of single-photon emission computed tomographic (SPECT) images, a restoration filter has been developed. This filter was designed according to practical 'least squares filter' theory. It is necessary to know the object power spectrum and the noise power spectrum. The power spectrum is estimated from the power spectrum of a projection, when the high-frequency power spectrum of a projection is adequately approximated as a polynomial exponential expression. A study of the restoration with the filter based on a projection power spectrum was conducted, and compared with that of the 'Butterworth' filtering method (cut-off frequency of 0.15 cycles/pixel), and 'Wiener' filtering (signal-to-noise power spectrum ratio was a constant). Normalized mean-squared errors (NMSE) of the phantom, two line sources located in a 99m Tc filled cylinder, were used. NMSE of the 'Butterworth' filter, 'Wiener' filter, and filtering based on a power spectrum were 0.77, 0.83, and 0.76 respectively. Clinically, brain SPECT images utilizing this new restoration filter improved the contrast. Thus, this filter may be useful in diagnosis of SPECT images. (author)

  13. Dementia due to normal-pressure hydrocephalus by single photon emission computer tomography

    International Nuclear Information System (INIS)

    Borbely, K.; Kordas, M.; Kadar, K.; Nyary, I.

    2002-01-01

    Aims: Once a diagnosis of dementia is established, the irreversible and degenerative types of dementia should be differentiated from those with potentially treatable causes. Normal-pressure hydrocephalus (NPH) is a reversible and poorly understood cause of mental impairment. Ventricular enlargement as registered by Computer Tomography (CT) or Magnetic Resonance Imaging (MRI) might be neurologically stable or progressive in nature. CT/MRI can display the exact size and shape of the ventricles. However, either CT or MRI cerebrospinal fluid (CSF) flow studies are unable to predict the response to shunt operation. The purpose of this study was to determine the role of 99m Tc-HMPAO regional cerebral blood flow (rCBF) SPECT combined with 99m Tc-DTPA CSF-SPECT in the preoperative evaluation of patients with chronic hydrocephalus. Methods: 103 consecutive studies were carried out where patient management was of concern with a standard technique for each patient (555 MBq 99mTc-HMPAO/ECD; 250 MBq 99mTc-DTPA, 1/3/6/24 h planar, 6/24h SPECT; double head ADAC SPECT camera). RCBF SPECT studies were analysed visually and by a special region of interests (ROIs) program. Circular ROIs were placed over the striatum, thalamus, white matter, frontal, temporal, parietal, occipital cortex, and cerebellum. ROIs were normalized to the whole brain average. The statistical analysis was considered significant at P≤0.05. The results of combined SPECT studies were correlated with CT/MRI, and clinical findings. Results: In 75 cases the hydrocephalus appeared to be communicating. In 19 cases there was a contradiction between the results of CT/MRI and CSF SPECT. 67 ventriculoperitoneal shunt implantations were carried out on the basis of combined SPECT studies. In 67 patients the rCBF SPECT except for hydrocephalus, demonstrated decreased rCBF in the periventricular white matter, thalamus and basal ganglia. There were additional bilateral rCBF abnormalities in the frontal or fronto

  14. Prospective Study of 68Ga-DOTATATE Positron Emission Tomography/Computed Tomography for Detecting Gastro-Entero-Pancreatic Neuroendocrine Tumors and Unknown Primary Sites.

    Science.gov (United States)

    Sadowski, Samira M; Neychev, Vladimir; Millo, Corina; Shih, Joanna; Nilubol, Naris; Herscovitch, Peter; Pacak, Karel; Marx, Stephen J; Kebebew, Electron

    2016-02-20

    Gastro-entero-pancreatic neuroendocrine tumors (GEPNETs) are increasing in incidence, and accurate staging is important for selecting the appropriate treatment. (68)Ga-DOTATATE imaging is a promising approach for detecting GEPNETs and could help in selecting optimal therapeutic strategies. The aim of this study was to prospectively determine the clinical utility of (68)Ga-DOTATATE positron emission tomography (PET)/computed tomography (CT) in detecting unknown primary and metastatic GEPNETs. One hundred thirty-one patients were enrolled in a prospective study of patients undergoing (68)Ga-DOTATATE PET/CT, (111)In-pentetreotide single-photon emission computed tomography (SPECT)/CT and multiphasic CT scan, and/or magnetic resonance imaging in a blinded fashion with comprehensive biochemical testing. The primary outcome measure was the detection of lesions by each imaging study. (68)Ga-DOTATATE PET/CT imaging detected 95.1% of lesions (95% CI, 92.4% to 96.8%) with an average maximum standardized uptake value of 65.4 ± 47 (range, 6.9 to 244), anatomic imaging detected 45.3% of lesions (95% CI, 37.9% to 52.9%), and (111)In-pentetreotide SPECT/CT detected 30.9% of lesions (95% CI, 25.0% to 37.5%), with a significant difference between imaging modalities (P < .001). In four of 14 patients (28.6%), (68)Ga-DOTATATE PET/CT found a previously unknown primary tumor, and detected primary GEPNET, lymph node, and distant metastases correctly in 72 of 113 lesions (63.7%) when compared with histopathology, with 22.1% and 38.9% detected by using (111)In-pentetreotide SPECT/CT and anatomic imaging, respectively. On the basis of findings with (68)Ga-DOTATATE PET/CT, 43 of 131 patients (32.8%) had a change in management recommendation. In patients with carcinoid symptoms but negative biochemical testing, (68)Ga-DOTATATE PET/CT detected lesions in 65.2% of patients, 40% of which were detected neither by anatomic imaging nor by (111)In-pentetreotide SPECT/CT. (68)Ga-DOTATATE PET

  15. The peculiarities of regional volume cerebral blood flow in patients with hypertensive encephalopathy by the findings of single photon emission computed tomography

    International Nuclear Information System (INIS)

    Makejev, S.S.; Novyikova, T.G.; Kustkova, A.S.

    2012-01-01

    The investigation of the state of the brain perfusion in patients with stage II hypertensive encephalopathy (HE) at development of hypertension crisis vs. crisis-free course of HE showed that in 79,5% of the patients with stage II HE, single photon emission computed tomography demonstrated local changes of the blood flow

  16. Benzodiazepine receptor equilibrium constants for flumazenil and midazolam determined in humans with the single photon emission computer tomography tracer [123I]iomazenil

    DEFF Research Database (Denmark)

    Videbaek, C; Friberg, L; Holm, S

    1993-01-01

    twice, once without receptor blockade and once with a constant degree of partial blockade of the benzodiazepine receptors by infusion of nonradioactive flumazenil (Lanexat) or midazolam (Dormicum). Single photon emission computer tomography and blood sampling were performed intermittently for 6 h after...

  17. I-123 iomazenil single photon emission computed tomography for detecting loss of neuronal integrity in patients with traumatic brain injury.

    Science.gov (United States)

    Abiko, Kagari; Ikoma, Katsunori; Shiga, Tohru; Katoh, Chietsugu; Hirata, Kenji; Kuge, Yuji; Kobayashi, Kentaro; Tamaki, Nagara

    2017-12-01

    Traumatic brain injury (TBI) causes brain dysfunction in many patients. Using C-11 flumazenil (FMZ) positron emission tomography (PET), we have detected and reported the loss of neuronal integrity, leading to brain dysfunction in TBI patients. Similarly to FMZ PET, I-123 iomazenil (IMZ) single photon emission computed tomography (SPECT) is widely used to determine the distribution of the benzodiazepine receptor (BZR) in the brain cortex. The purpose of this study is to examine whether IMZ SPECT is as useful as FMZ PET for evaluating the loss of neuronal integrity in TBI patients. The subjects of this study were seven patients who suffered from neurobehavioral disability. They underwent IMZ SPECT and FMZ PET. Nondisplaceable binding potential (BP ND ) was calculated from FMZ PET images. The uptake of IMZ was evaluated on the basis of lesion-to-pons ratio (LPR). The locations of low uptake levels were visually evaluated both in IMZ SPECT and FMZ PET images. We compared FMZ BP ND and (LPR-1) of IMZ SPECT. In the visual assessment, FMZ BP ND decreased in 11 regions. In IMZ SPECT, low uptake levels were observed in eight of the 11 regions. The rate of concordance between FMZ PET and IMZ SPECT was 72.7%. The mean values IMZ (LPR-1) (1.95 ± 1.01) was significantly lower than that of FMZ BP ND (2.95 ± 0.80 mL/mL). There was good correlation between FMZ BP ND and IMZ (LPR-1) (r = 0.80). IMZ SPECT findings were almost the same as FMZ PET findings in TBI patients. The results indicated that IMZ SPECT is useful for evaluating the loss of neuronal integrity. Because IMZ SPECT can be performed in various facilities, IMZ SPECT may become widely adopted for evaluating the loss of neuronal integrity.

  18. Relationship Between Quantitative Adverse Plaque Features From Coronary Computed Tomography Angiography and Downstream Impaired Myocardial Flow Reserve by 13N-Ammonia Positron Emission Tomography: A Pilot Study.

    Science.gov (United States)

    Dey, Damini; Diaz Zamudio, Mariana; Schuhbaeck, Annika; Juarez Orozco, Luis Eduardo; Otaki, Yuka; Gransar, Heidi; Li, Debiao; Germano, Guido; Achenbach, Stephan; Berman, Daniel S; Meave, Aloha; Alexanderson, Erick; Slomka, Piotr J

    2015-10-01

    We investigated the relationship of quantitative plaque features from coronary computed tomography (CT) angiography and coronary vascular dysfunction by impaired myocardial flow reserve (MFR) by (13)N-Ammonia positron emission tomography (PET). Fifty-one patients (32 men, 62.4±9.5 years) underwent combined rest-stress (13)N-ammonia PET and CT angiography scans by hybrid PET/CT. Regional MFR was measured from PET. From CT angiography, 153 arteries were evaluated by semiautomated software, computing arterial noncalcified plaque (NCP), low-density NCP (NCP<30 HU), calcified and total plaque volumes, and corresponding plaque burden (plaque volumex100%/vessel volume), stenosis, remodeling index, contrast density difference (maximum difference in luminal attenuation per unit area in the lesion), and plaque length. Quantitative stenosis, plaque burden, and myocardial mass were combined by boosted ensemble machine-learning algorithm into a composite risk score to predict impaired MFR (MFR≤2.0) by PET in each artery. Nineteen patients had impaired regional MFR in at least 1 territory (41/153 vessels). Patients with impaired regional MFR had higher arterial NCP (32.4% versus 17.2%), low-density NCP (7% versus 4%), and total plaque burden (37% versus 19.3%, P<0.02). In multivariable analysis with 10-fold cross-validation, NCP burden was the most significant predictor of impaired MFR (odds ratio, 1.35; P=0.021 for all). For prediction of impaired MFR with 10-fold cross-validation, receiver operating characteristics area under the curve for the composite score was 0.83 (95% confidence interval, 0.79-0.91) greater than for quantitative stenosis (0.66, 95% confidence interval, 0.57-0.76, P=0.005). Compared with stenosis, arterial NCP burden and a composite score combining quantitative stenosis and plaque burden from CT angiography significantly improves identification of downstream regional vascular dysfunction. © 2015 American Heart Association, Inc.

  19. Respiratory-Gated Positron Emission Tomography and Breath-Hold Computed Tomography Coupling to Reduce the Influence of Respiratory Motion: Methodology and Feasibility

    International Nuclear Information System (INIS)

    Daouk, J.; Fin, L.; Bailly, P.; Meyer, M.E.

    2009-01-01

    Background: Respiratory motion causes uptake in positron emission tomography (PET) images of chest and abdominal structures to be blurred and reduced in intensity. Purpose: To compare two respiratory-gated PET binning methods (based on frequency and amplitude analyses of the respiratory signal) and to propose a 'BH-based' method based on an additional breath-hold computed tomography (CT) acquisition. Material and Methods: Respiratory-gated PET consists in list-mode (LM) acquisition with simultaneous respiratory signal recording. A phantom study featured rectilinear movement of a 0.5-ml sphere filled with 18 F-fluorodeoxyglucose ( 18 F-FDG) solution, placed in a radioactive background (sphere-to-background contrast 6:1). Two patients were also examined. Three figures of merit were calculated: the target-to-background ratio profile (TBRP) in the axial direction through the uptake (i.e., the sphere or lesion), full-width-at-half-maximum (FWHM) values, and maximized standard uptake values (SUVmax). Results: In the phantom study, the peak TBRP was 0.9 for non-gated volume, 1.83 for BH-based volume, and varied between 1.13 and 1.73 for Freq-based volumes and between 1.34 and 1.66 for Amp-based volumes. A reference volume (REF-static) was also acquired for the phantom (in a static, 'expiratory' state), with a peak TBRP at 1.88. TBRPs were computed for patient data, with higher peak values for all gated volumes than for non-gated volumes. Conclusion: Respiratory-gated PET acquisition reduces the blurring effect and increases image contrast. However, Freq-based and Amp-based volumes are still influenced by inappropriate attenuation correction and misregistration of mobile lesions on CT images. The proposed BH-based method both reduces motion artifacts and improves PET-CT registration

  20. Positron Emission Tomography/Computed Tomography Imaging of Residual Skull Base Chordoma Before Radiotherapy Using Fluoromisonidazole and Fluorodeoxyglucose: Potential Consequences for Dose Painting

    Energy Technology Data Exchange (ETDEWEB)

    Mammar, Hamid, E-mail: hamid.mammar@unice.fr [Radiation Oncology Department, Antoine Lacassagne Center, Nice (France); CNRS-UMR 6543, Institute of Developmental Biology and Cancer, University of Nice Sophia Antipolis, Nice (France); Kerrou, Khaldoun; Nataf, Valerie [Department of Nuclear Medicine and Radiopharmacy, Tenon Hospital, and University Pierre et Marie Curie, Paris (France); Pontvert, Dominique [Proton Therapy Center of Orsay, Curie Institute, Paris (France); Clemenceau, Stephane [Department of Neurosurgery, Pitie-Salpetriere Hospital, Paris (France); Lot, Guillaume [Department of Neurosurgery, Adolph De Rothschild Foundation, Paris (France); George, Bernard [Department of Neurosurgery, Lariboisiere Hospital, Paris (France); Polivka, Marc [Department of Pathology, Lariboisiere Hospital, Paris (France); Mokhtari, Karima [Department of Pathology, Pitie-Salpetriere Hospital, Paris (France); Ferrand, Regis; Feuvret, Loiec; Habrand, Jean-louis [Proton Therapy Center of Orsay, Curie Institute, Paris (France); Pouyssegur, Jacques; Mazure, Nathalie [CNRS-UMR 6543, Institute of Developmental Biology and Cancer, University of Nice Sophia Antipolis, Nice (France); Talbot, Jean-Noeel [Department of Nuclear Medicine and Radiopharmacy, Tenon Hospital, and University Pierre et Marie Curie, Paris (France)

    2012-11-01

    Purpose: To detect the presence of hypoxic tissue, which is known to increase the radioresistant phenotype, by its uptake of fluoromisonidazole (18F) (FMISO) using hybrid positron emission tomography/computed tomography (PET/CT) imaging, and to compare it with the glucose-avid tumor tissue imaged with fluorodeoxyglucose (18F) (FDG), in residual postsurgical skull base chordoma scheduled for radiotherapy. Patients and Methods: Seven patients with incompletely resected skull base chordomas were planned for high-dose radiotherapy (dose {>=}70 Gy). All 7 patients underwent FDG and FMISO PET/CT. Images were analyzed qualitatively by visual examination and semiquantitatively by computing the ratio of the maximal standardized uptake value (SUVmax) of the tumor and cerebellum (T/C R), with delineation of lesions on conventional imaging. Results: Of the eight lesion sites imaged with FDG PET/CT, only one was visible, whereas seven of nine lesions were visible on FMISO PET/CT. The median SUVmax in the tumor area was 2.8 g/mL (minimum 2.1; maximum 3.5) for FDG and 0.83 g/mL (minimum 0.3; maximum 1.2) for FMISO. The T/C R values ranged between 0.30 and 0.63 for FDG (median, 0.41) and between 0.75 and 2.20 for FMISO (median,1.59). FMISO T/C R >1 in six lesions suggested the presence of hypoxic tissue. There was no correlation between FMISO and FDG uptake in individual chordomas (r = 0.18, p = 0.7). Conclusion: FMISO PET/CT enables imaging of the hypoxic component in residual chordomas. In the future, it could help to better define boosted volumes for irradiation and to overcome the radioresistance of these lesions. No relationship was founded between hypoxia and glucose metabolism in these tumors after initial surgery.

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Share your patient story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related ...

  5. Computed tomography in traumatology

    International Nuclear Information System (INIS)

    Heller, M.; Jend, H.H.

    1986-01-01

    This volume offers a critical review and assessment of new avenues opened up by computed tomography in traumatology. Over 200 illustrations, including numerous CT scans, aid the physician engaged emergency care and postoperative treatment of accident victims. Technical prerequisites, special techniques of investigation, pathomorphology of organ changes conditioned by trauma, diagnostic leading symptoms and signs, and diagnostics of iatrogenic injuries and lesions are presented

  6. Computed tomography system

    International Nuclear Information System (INIS)

    Lambert, T.W.; Blake, J.E.

    1981-01-01

    This invention relates to computed tomography and is particularly concerned with determining the CT numbers of zones of interest in an image displayed on a cathode ray tube which zones lie in the so-called level or center of the gray scale window. (author)

  7. Chest computed tomography

    DEFF Research Database (Denmark)

    Loeve, Martine; Krestin, Gabriel P.; Rosenfeld, Margaret

    2013-01-01

    are not suitable to study CF lung disease in young children. Chest computed tomography (CT) holds great promise for use as a sensitive surrogate endpoint in CF. A large body of evidence has been produced to validate the use of chest CT as primary endpoint to study CF lung disease. However, before chest CT can...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the sinuses uses special x-ray equipment to evaluate the paranasal sinus cavities – hollow, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  10. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.J.

    1986-01-01

    This book is directed towards giving radiographers an introduction to and basic knowledge of computerized tomography. The technical section discusses gantries and x-ray production, computer and disc drive image display, storage, artefacts quality assurance and design of departments. The clinical section includes patient preparation, radiotherapy planning, and interpretation of images from various areas of the anatomy. (U.K.)

  11. Positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lindback, Stig [GEMS PET Systems AB, Uppsala (Sweden)

    1995-07-15

    Positron Emission Tomography (PET) is an advanced nuclear medicine technique used for research at major centres. Unique diagnostic information is obtained from tomographic measurements of the biochemistry and physiology of tissues and organs. In theory, diseases are related to biochemical changes and these can be observed with PET long before any anatomical changes are detectable. In PET the radioactive component is a positron-emitting isotope or 'tracer'. The positrons annihilate with electrons in the body to produce two gamma rays 180° apart; coincidence detection of these gammas provides a very efficient method of determining the spatial distribution of the radioisotope tracer. Because physiological measurements are usually required in a single imaging session, very short-lived isotopes are used to label the tracer molecules; isotope production and labelling is usually carried out in situ. The most commonly used radionuclides are carbon- 11 (half-life 20 minutes), nitrogen-13 (10 minutes), oxygen-15 (2 minutes), and fluorine-18 (110 minutes). A PET system has three major components: - a particle accelerator with targets for production of the positron-emitting isotopes; - chemistry modules for synthesis and labelling of the desired tracers; - and a PET camera for in-vivo measurements of the distribution of the tracer in the body.

  12. Positron emission tomography

    International Nuclear Information System (INIS)

    Lindback, Stig

    1995-01-01

    Positron Emission Tomography (PET) is an advanced nuclear medicine technique used for research at major centres. Unique diagnostic information is obtained from tomographic measurements of the biochemistry and physiology of tissues and organs. In theory, diseases are related to biochemical changes and these can be observed with PET long before any anatomical changes are detectable. In PET the radioactive component is a positron-emitting isotope or 'tracer'. The positrons annihilate with electrons in the body to produce two gamma rays 180° apart; coincidence detection of these gammas provides a very efficient method of determining the spatial distribution of the radioisotope tracer. Because physiological measurements are usually required in a single imaging session, very short-lived isotopes are used to label the tracer molecules; isotope production and labelling is usually carried out in situ. The most commonly used radionuclides are carbon- 11 (half-life 20 minutes), nitrogen-13 (10 minutes), oxygen-15 (2 minutes), and fluorine-18 (110 minutes). A PET system has three major components: - a particle accelerator with targets for production of the positron-emitting isotopes; - chemistry modules for synthesis and labelling of the desired tracers; - and a PET camera for in-vivo measurements of the distribution of the tracer in the body

  13. ¹⁸F-fluorodeoxyglucose-positron emission tomography/computed tomography in malignancies of the thyroid and in head and neck squamous cell carcinoma: a review of the literature.

    Science.gov (United States)

    Lauridsen, Jeppe Kiilerich; Rohde, Max; Thomassen, Anders

    2015-01-01

    18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) is a valuable diagnostic tool in a spectrum of malignant and benign conditions, because of a high sensitivity to detect even very small lesions with increased metabolism. This review focuses on the use of FDG-PET/CT in malignancies of the thyroid gland and in head and neck squamous cell carcinoma. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Use of 99mTc-sestamibi Single-photon Emission Computed Tomography / X-ray Computed Tomography in the Diagnosis of Hybrid Oncocytic / Chromophobe Tumor in a Pediatric Patient.

    Science.gov (United States)

    Almassi, Nima; Gorin, Michael A; Purysko, Andrei S; Rowe, Steven P; Kaouk, Jihad; Allaf, Mohamad E; Campbell, Steven C; Rhee, Audrey

    2018-03-01

    The differential diagnosis of solid renal neoplasms in adolescence includes aggressive malignancy and indolent oncocytic tumors, which are typically indistinguishable using conventional imaging. We report the use of 99m Tc-sestamibi single-photon emission computed tomography / x-ray computed tomography (SPECT/CT) in characterizing enhancing renal neoplasms in a pediatric patient. Genetic testing suggested a hereditary syndrome associated with aggressive malignancy, whereas renal mass biopsy suggested an oncocytic tumor. 99m Tc-sestamibi SPECT/CT indicated probable oncocytomas or hybrid oncocytic / chomophobe tumors. Enucleative resection was performed with final pathology demonstrating hybrid oncocytic / chomophobe tumors. This case highlights the potential utility of 99m Tc-sestamibi SPECT/CT in characterizing indeterminate enhancing renal neoplasm in pediatric patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. [The value of multimodal imaging by single photon emission computed tomography associated to X ray computed tomography (SPECT-CT) in the management of differentiated thyroid carcinoma: about 156 cases].

    Science.gov (United States)

    Mhiri, Aida; El Bez, Intidhar; Slim, Ihsen; Meddeb, Imène; Yeddes, Imene; Ghezaiel, Mohamed; Gritli, Saïd; Ben Slimène, Mohamed Faouzi

    2013-10-01

    Single photon emission computed tomography combined with a low dose computed tomography (SPECT-CT), is a hybrid imaging integrating functional and anatomical data. The purpose of our study was to evaluate the contribution of the SPECTCT over traditional planar imaging of patients with differentiated thyroid carcinoma (DTC). Post therapy 131IWhole body scan followed by SPECTCT of the neck and thorax, were performed in 156 patients with DTC. Among these 156 patients followed for a predominantly papillary, the use of fusion imaging SPECT-CT compared to conventional planar imaging allowed us to correct our therapeutic approach in 26.9 % (42/156 patients), according to the protocols of therapeutic management of our institute. SPECT-CT is a multimodal imaging providing better identification and more accurate anatomic localization of the foci of radioiodine uptake with impact on therapeutic management.

  16. Update on nodal staging in non-small cell lung cancer with integrated positron emission tomography/computed tomography: a meta-analysis.

    Science.gov (United States)

    Pak, Kyoungjune; Park, Sohyun; Cheon, Gi Jeong; Kang, Keon Wook; Kim, In-Joo; Lee, Dong Soo; Kim, E Edmund; Chung, June-Key

    2015-06-01

    Nowadays, the number of primary studies on fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) has been increasing rapidly. Thus, we updated meta-analysis to evaluate the test performance of FDG PET/CT for nodal staging in non-small cell lung cancer (NSCLC) including the most recent studies. We performed a systematic search of MEDLINE and EMBASE for English publications using keywords "positron emission tomography", "lung cancer", and "lymph node". All searches were limited to human studies. Inclusion criteria were studies of the initial nodal staging of NSCLC with PET/CT. The reasons for exclusion are as follows: (1) studies with PET, (2) previous therapy before PET/CT, (3) nodal staging not confirmed by histology, and (4) reviews, abstracts, and editorial materials. 786 articles were identified through database searching. 28 studies including 3,255 patients and 11,887 lymph nodes (LN) were eligible for this study. The pooled sensitivity was 0.62 (95% CI 0.54-0.70), widely ranging from 0.13 to 0.98. The specificity ranged between 0.72 and 0.98 with an overall estimated specificity of 0.92 (0.88-0.95) for node-based data. The pooled sensitivity, specificity, positive and negative likelihood ratio were 0.67 (0.54-0.79), 0.87 (0.82-0.91), 5.20 (3.59-7.54), and 0.37 (0.25-0.55) for patient-based data. Studies from tuberculosis (Tb) endemic countries showed lower sensitivity (0.56 vs 0.68, p = 0.03) for node-based data and lower specificity (0.83 vs 0.89, p < 0.01) for patient-based ones. PET/CT has a high specificity, but low sensitivity for detecting LN metastasis in patients with NSCLC. Tb might be one of the main reasons for lower sensitivity of PET/CT in several countries. The primary clinicians of lung cancer should be aware of the possibility of hidden metastatic LNs in bilateral FDG uptake of mediastinal and hilar LNs, especially in the Tb endemic countries.

  17. Quantitative cardiac computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Thelen, M.; Dueber, C.; Wolff, P.; Erbel, R.; Hoffmann, T.

    1985-06-01

    The scope and limitations of quantitative cardiac CT have been evaluated in a series of experimental and clinical studies. The left ventricular muscle mass was estimated by computed tomography in 19 dogs (using volumetric methods, measurements in two axes and planes and reference volume). There was good correlation with anatomical findings. The enddiastolic volume of the left ventricle was estimated in 22 patients with cardiomyopathies; using angiography as a reference, CT led to systematic under-estimation. It is also shown that ECG-triggered magnetic resonance tomography results in improved visualisation and may be expected to improve measurements of cardiac morphology.

  18. Improvement in the detection of locoregional recurrence in head and neck malignancies: F-18 fluorodeoxyglucose-positron emission tomography/computed tomography compared to high-resolution contrast-enhanced computed tomography and endoscopic examination.

    Science.gov (United States)

    Rangaswamy, Balasubramanya; Fardanesh, M Reza; Genden, Eric M; Park, Eunice E; Fatterpekar, Girish; Patel, Zara; Kim, Jongho; Som, Peter M; Kostakoglu, Lale

    2013-11-01

    To compare the diagnostic efficacy of positron emission tomography (PET) with F-18 fluorodeoxyglucose (FDG-PET)/computed tomography (CT) to that of contrast-enhanced high-resolution CT (HRCT) and assess the value of a combinatorial approach in detection of recurrent squamous cell cancer of the head and neck (HNC) and to assess the efficacy of FDG-PET/CT with and without HRCT in comparison to standard-of-care follow-up--physical examination (PE) and endoscopy (E)--in determination of locally recurrent HNC. Retrospective study. A total of 103 patients with HNC underwent FDG-PET/CT and neck HRCT. There were two groups of patients: Group A had an FDG-PET study acquired with low-dose CT, and group B had an FDG-PET study acquired with HRCT. The PET data obtained with or without HRCT were compared on a lesion and patient basis with the results of the PE/E. On a lesion basis, both groups combined had higher sensitivity and negative predictive value (NPV) than the HRCT. Specificity and positive predictive value (PPV) for group B were higher than for group A. On a patient basis, both groups combined had a higher sensitivity and NPV than PE/E, respectively, although specificity of PE/E was higher than that of either group. PET data obtained with either protocol directly influenced treatment. HRCT increases the specificity and PPV of PET/CT when acquired simultaneously with PET. FDG-PET/CT acquired with either LDCT or HRCT has higher accuracy than HRCT alone and increases the sensitivity and NPV of PE/E. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  19. Detection of distant metastases in patients with locally advanced breast cancer: role of {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography and conventional imaging with computed tomography scans

    Energy Technology Data Exchange (ETDEWEB)

    Bitencourt, Almir Galvao Vieira; Andrade, Wesley Pereira; Cunha, Rodrigo Rodrigues da; Conrado, Jorge Luis Fonseca de Acioli; Lima, Eduardo Nobrega Pereira; Barbosa, Paula Nicole Vieira Pinto; Chojniak, Rubens, E-mail: rodrigo.rcunha@hotmail.com [A. C. Camargo Cancer Center, Sao Paulo, SP (Brazil); Hospital Beneficincia Portuguesa de Sao Paulo, Sao Paulo, SP (Brazil)

    2017-07-15

    Objective: To evaluate positron emission tomography/computed tomography (PET/CT) and conventional imaging tests for the detection of distant metastases in patients with locally advanced breast cancer. Materials and Methods: We included 81 patients with breast cancer who had undergone {sup 18}-fluorodeoxyglucose (FDG) PET/CT before treatment. Conventional imaging included the following: bone scintigraphy; chest X-ray (in 14.5%) or CT (in 85.5%); and abdominal ultrasound (in 10.8%), CT (in 87.8%), or magnetic resonance imaging (in 1.4%). Histopathology and clinical/imaging follow-up served as reference. Results: Distant metastases were observed in nine patients (11.1%). On patient-based analysis, conventional imaging identified distant metastases in all 9 patients. In one patient, the initial {sup 18}F-FDG PET/CT failed to demonstrate bone metastases that was evident on bone scintigraphy. In two patients, the CT scan failed to show extra-axillary lymph node metastases that were identified on {sup 18}F-FDG PET/CT. There was no significant difference between {sup 18}F-FDG PET/CT and conventional imaging in terms of their sensitivity for the detection of distant metastases in patients with locally advanced breast cancer. Conclusion: This study showed that {sup 18}F-FDG PET/CT and conventional imaging with CT scans had similar sensitivity for the diagnosis of distant metastases in patients with locally advanced breast cancer. {sup 18}F-FDG PET/CT can add information about extra-axillary lymph node involvements. (author)

  20. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  1. What is the purpose of emission computed tomography in nuclear medicine

    International Nuclear Information System (INIS)

    Phelps, M.E.

    1977-01-01

    ECT is a mathematical and physical concept, an instrument, a radionuclide tracer technique, a research procedure and it is certainly both an old (Kuhl began his work in the late fifties) and a new concept. It also has great and unique potential as a diagnostic technique. It is interesting that the basic principles of medical CT were exemplified and developed in Nuclear Medicine by Kuhl and coworkers and the concept of ''physiologic or function tomography'' provides a technique to advance the original charter of Nuclear Medicine in the use of radionuclides for the measure of metabolism and physiologic function

  2. Computed tomography by reconstruction. Brain CT scanning. I. Basic physics, equipment, normal aspects, artefacts

    International Nuclear Information System (INIS)

    Chiras, J.; Palmieri, P.; Saudinos, J.; Salamon, G.

    1980-01-01

    The authors describe the physical basis, apparatus, normal images, and artefacts of computed tomography by reconstruction. Radio-anatomical sections enable clear comprehension of the computed tomography images. Other methods using computer reconstruction are outlined: tomography by Compton effect, tomography by positrons, tomography by gamma emission, tomography by protons, tomography by nuclear magnetic resonance [fr

  3. The application of positron emission tomography/computed tomography in radiation treatment planning: effect on gross target volume definition and treatment management.

    Science.gov (United States)

    Iğdem, S; Alço, G; Ercan, T; Unalan, B; Kara, B; Geceer, G; Akman, C; Zengin, F O; Atilla, S; Okkan, S

    2010-04-01

    To analyse the effect of the use of molecular imaging on gross target volume (GTV) definition and treatment management. Fifty patients with various solid tumours who underwent positron emission tomography (PET)/computed tomography (CT) simulation for radiotherapy planning from 2006 to 2008 were enrolled in this study. First, F-18 fluorodeoxyglucose (FDG)-PET and CT scans of the treatment site in the treatment position and then a whole body scan were carried out with a dedicated PET/CT scanner and fused thereafter. FDG-avid primary tumour and lymph nodes were included into the GTV. A multidisciplinary team defined the target volume, and contouring was carried out by a radiation oncologist using visual methods. To compare the PET/CT-based volumes with CT-based volumes, contours were drawn on CT-only data with the help of site-specific radiologists who were blind to the PET/CT results after a median time of 7 months. In general, our PET/CT volumes were larger than our CT-based volumes. This difference was significant in patients with head and neck cancers. Major changes (> or =25%) in GTV delineation were observed in 44% of patients. In 16% of cases, PET/CT detected incidental second primaries and metastatic disease, changing the treatment strategy from curative to palliative. Integrating functional imaging with FDG-PET/CT into the radiotherapy planning process resulted in major changes in a significant proportion of our patients. An interdisciplinary approach between imaging and radiation oncology departments is essential in defining the target volumes. Copyright 2010 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  4. The value of F-18 fluorodeoxyglucose positron emission tomography/computed tomography in asymptomatic examinees with unexplained elevated blood carcinoembryonic antigen levels

    Energy Technology Data Exchange (ETDEWEB)

    Li, Wenfeng [The First Affiliated Hospital of Wenzhou Medical University, Laboratory for Advanced Interdisciplinary Research, Institutes of Translational Medicine, Wenzhou (China); The First Affiliated Hospital of Wenzhou Medical University, Department of Radiation Oncology, Wenzhou (China); Yin, Weiwei [The First Affiliated Hospital of Wenzhou Medical University, Division of PET/CT, Department of Radiology, Wenzhou (China); Ou, Rongying [The First Affiliated Hospital of Wenzhou Medical University, Laboratory for Advanced Interdisciplinary Research, Institutes of Translational Medicine, Wenzhou (China); The First Affiliated Hospital of Wenzhou Medical University, Department of Gynaecology and Obstetrics, Wenzhou (China); Chen, Ting; Xiong, Lingling; Xu, Yunsheng [The First Affiliated Hospital of Wenzhou Medical University, Laboratory for Advanced Interdisciplinary Research, Institutes of Translational Medicine, Wenzhou (China); The First Affiliated Hospital of Wenzhou Medical University, Department of Dermatovenereology, Wenzhou (China); Cheng, Dezhi; Xie, Deyao [The First Affiliated Hospital of Wenzhou Medical University, Laboratory for Advanced Interdisciplinary Research, Institutes of Translational Medicine, Wenzhou (China); The First Affiliated Hospital of Wenzhou Medical University, Department of Cardiothoracic Surgery, Wenzhou (China); Zheng, Xiangwu; Zhao, Liang [The First Affiliated Hospital of Wenzhou Medical University, Laboratory for Advanced Interdisciplinary Research, Institutes of Translational Medicine, Wenzhou (China); The First Affiliated Hospital of Wenzhou Medical University, Division of PET/CT, Department of Radiology, Wenzhou (China); The First Affiliated Hospital of Wenzhou Medical University, Institutes of Intelligent and Molecular Imaging, Wenzhou (China)

    2016-04-15

    Cancer is still a clinical challenge, with many efforts invested in order to achieve timely detection. Unexplained elevated blood carcinoembryonic antigen levels are occasionally observed in an asymptomatic population and considered as a risk factor of cancers. The purpose of this study was to determine the validity of 18 F-fluorodeoxyglucose-positron emission tomography/computed tomography (F-18 FDG-PET/CT) for detecting cancer in an asymptomatic population with an unexplained elevation in blood carcinoembryonic antigen (CEA) levels. This retrospective study included a total of 1920 asymptomatic examinees conducted from August 2011 through September 2013. The participants underwent CEA assay and conventional medical imaging (CEA-conventional), or CEA assay and F-18 FDG-PET/CT (CEA-PET/CT). The validity of conventional medical imaging and CEA-PET/CT scanning for detecting cancer and early-stage cancer in an asymptomatic population with an unexplained elevation in blood CEA levels were evaluated. Sensitivity, specificity, cancer detection rate, missed cancer detection rate, early-stage cancer detection rate, and early-stage cancer ratio using the CEA-PET/CT scanning were 96.6 %, 100 %, 10.4 %, 0.4 %, 3.7 %, and 34.5 %, respectively. In contrast, the corresponding values obtained using the conventional medical imaging were 50.6 % (P < 0.0001), 100 % (P > 0.9999), 50.6 % (P < 0.0001), 99.9 % (P = 0.055), 2.6 % (P < 0.0001), 2.5 % (P = 0.04), 0.7 % (P = 0.0004), and 14.5 % (P = 0.002), respectively. The F-18 FDG-PET/CT scanning significantly improved the validity of the cancer detection program in the asymptomatic population with an unexplained elevation in CEA levels. (orig.)

  5. 18-F flourodeoxy glucose positron emission tomography-computed tomography imaging: A viable alternative to three phase bone scan in evaluating diabetic foot complications?

    International Nuclear Information System (INIS)

    Shagos, G. S.; Shanmugasundaram, Palaniswamy; Varma, Ajith Kumar; Padma, Subramanyam; Sarma, Manjit

    2015-01-01

    This paper is based on the initial findings from a prospective ongoing study to evaluate the efficacy of flourodeoxy glucose positron emission tomography-computed tomography (FDG-PET CT) in diabetic foot evaluation. The aim was to compare the diagnostic accuracies of three phase bone scan (TPBS) and FDG PET-CT (FDG-PET) in diabetic foot evaluation. Seventy-nine patients with complicated diabetic foot (osteomyelitis/cellulitis, Charcot's neuropathy) were prospectively investigated. TPBS (15 mci methylene di phosphonate [MDP] intravenous [IV]), followed by FDG-PET (5 mci IV) within 5 days were performed in all patients. Based on referral indication, patients grouped into Group I, n = 36, (?osteomyelitis/cellulitis) and Group II, n = 43 (?Charcot's neuropathy). Interpretation was based on intensity, extent, pattern of MDP and FDG uptake (standardized uptake value) along with CT correlation. Findings were compared with final diagnostic outcome based on bone/soft tissue culture in Group I and clinical, radiological or scintigraphic followup in Group II. Results: Group I: For diagnosing osteomyelitis, TP: TN: FP: FN were 14:5:2:2 by FDG PET and 13:02:05:03 by TPBS respectively. Sensitivity, specificity, positive predictive value and negative predictive value (NPV) of FDG-PET were 87.5%, 71%, 87.5% and 71% and 81.25%, 28.5%, 72% and 40% for TPBS, respectively. Group II: charcot's: cellulitis: Normal were 22:14:7 by FDG PET and 32:5:6 by TPBS, respectively. Flo