WorldWideScience

Sample records for eluting beads results

  1. Chemoembolization (TACE) of Unresectable Intrahepatic Cholangiocarcinoma with Slow-Release Doxorubicin-Eluting Beads: Preliminary Results

    International Nuclear Information System (INIS)

    Aliberti, Camillo; Benea, Giorgio; Tilli, Massimo; Fiorentini, Giammaria

    2008-01-01

    The purpose of this study was to evaluate the safety and efficacy of TACE with microspheres preloaded with doxorubicin in unresectable intrahepatic cholangiocarcinoma (UCH). Twenty patients with UCH were observed; 9 refused, preferring other palliative care or chemotherapy, and 11 agreed to be treated with one or more cycles of DC beads loaded with doxorubicin (100-150 mg) in a TACE procedure between February 2006 and September 2007. A total of 29 individual TACE procedures were performed. Follow-up imaging was performed on all patients before, immediately after, and 4 weeks after each TACE procedure to evaluate the response and need for further treatment. Each patient received i.v hydration, antibiotics, and medications against nausea and pain before TACE. Survival rate was calculated using Kaplan-Meier survival curve. A response rate of 100% followed RECIST criteria was observed. Eight of eleven patients are alive, with a median survival of 13 months. TACE was well tolerated by all patients. One patient developed hepatic abscess requiring antibiotic therapy. No evidence of marrow toxicity has been reported. Only one of nine patients treated with chemotherapy or palliative care is alive (with a median survival of 7 months in this group of patients). In conclusion, we suggest that doxorubicin-eluting beads TACE is a feasible and effective treatment in patients with UCH. Survival seems to be clearly prolonged in the treated group with respect to the palliative group. We consider that doxorubicin-eluting beads TACE of 100-150 mg may be an appropriate palliative therapy for these patients. Further studies are warranted to confirm these interesting preliminary data.

  2. Toxicity of Irinotecan-Eluting Beads in the Treatment of Hepatic Malignancies: Results of a Multi-Institutional Registry

    International Nuclear Information System (INIS)

    Martin, R. C. G.; Howard, J.; Tomalty, D.; Robbins, K.; Padr, R.; Bosnjakovic, P. M.; Tatum, Cliff

    2010-01-01

    PurposeTo evaluate the predictors of toxicity of drug-eluting beads loaded with irinotecan (DEBIRI) in the treatment of hepatic malignancies.Materials and MethodsA total of 330 patients were enrolled in a prospective, open-label, multicenter, multinational, single-arm study administering two types of drug-eluting beads (DEBIRI and drug-eluting beads loaded with doxorubicin). Complications were graded by Cancer Therapy Evaluation Program's Common Terminology Criteria for Adverse Events (CTCAE) version 3.0. All events requiring additional physician treatment or requiring extended hospital stay or readmission within 30 days were included.ResultsA total of 109 patients received 187 DEBIRI treatments (range 1 to 5 per patient). The most common histology was metastatic colorectal cancer in 76% of patients, cholangiocarcinoma in 7% of patients, and other metastatic disease in 17% of patients. There were 35 patients (19%) with irinotecan treatments who sustained 158 treatment-related adverse events, with the median CTCAE event grade being CTCAE grade 2 (range 1 to 5). The most common adverse events were postembolic symptoms (42%). Multivariate analysis identified pretreatment and treatment-related risk factors as follows: lack of pretreatment with hepatic arterial lidocaine (p = 0.005), ≥3 treatments (p = 0.05), achievement of complete stasis (p = 0.04), treatment with >100 mg DEBIRI in 1 treatment (p = 0.03), and bilirubin >2.0 μg/dl with >50% liver involvement (p = 0.05). These factors were predictive of adverse events and significantly greater hospital length of stay.ConclusionsDEBIRI is safe when appropriate technique and treatment are used. Adverse events can be predicted based on pretreatment- and treatment-related factors, and their occurrence can become part of the informed consent process. Continued standardization of this treatment will lead to fewer adverse events and improved patient quality of life.

  3. Transarterial chemoembolization with drug-eluting beads in hepatocellular carcinoma

    Science.gov (United States)

    Nam, Hee Chul; Jang, Bohyun; Song, Myeong Jun

    2016-01-01

    Transarterial chemoembolization (TACE) is a widely used standard treatment for patients with hepatocellular carcinoma (HCC) who are not suitable candidates for curative treatments. The rationale for TACE is that intra-arterial chemotherapy using lipiodol and chemotherapeutic agents, followed by selective vascular embolization, results in a strong cytotoxic effect as well as ischemia (conventional TACE). Recently, drug-eluting beads (DC Beads®) have been developed for transcatheter treatment of HCC to deliver higher doses of the chemotherapeutic agent and to prolong contact time with the tumor. DC Beads® can actively sequester doxorubicin hydrochloride from solution and release it in a controlled sustained fashion. Treatment with DC Beads® substantially reduced the amount of chemotherapeutic agent that reached the systemic circulation compared with conventional, lipiodol-based regimens, significantly reducing drug-related adverse events. In this article, we describe the treatment response, survival, and safety of TACE used with drug-eluting beads for the treatment of HCC and discuss future therapeutic possibilities. PMID:27833376

  4. Prospective Randomized Study of Doxorubicin-Eluting-Bead Embolization in the Treatment of Hepatocellular Carcinoma: Results of the PRECISION V Study

    International Nuclear Information System (INIS)

    Lammer, Johannes; Malagari, Katarina; Vogl, Thomas; Pilleul, Frank; Denys, Alban; Watkinson, Anthony; Pitton, Michael; Sergent, Geraldine; Pfammatter, Thomas; Terraz, Sylvain; Benhamou, Yves; Avajon, Yves; Gruenberger, Thomas; Pomoni, Maria; Langenberger, Herbert; Schuchmann, Marcus; Dumortier, Jerome; Mueller, Christian; Chevallier, Patrick; Lencioni, Riccardo

    2010-01-01

    Transcatheter arterial chemoembolization (TACE) offers a survival benefit to patients with intermediate hepatocellular carcinoma (HCC). A widely accepted TACE regimen includes administration of doxorubicin-oil emulsion followed by gelatine sponge-conventional TACE. Recently, a drug-eluting bead (DC Bead) has been developed to enhance tumor drug delivery and reduce systemic availability. This randomized trial compares conventional TACE (cTACE) with TACE with DC Bead for the treatment of cirrhotic patients with HCC. Two hundred twelve patients with Child-Pugh A/B cirrhosis and large and/or multinodular, unresectable, N0, M0 HCCs were randomized to receive TACE with DC Bead loaded with doxorubicin or cTACE with doxorubicin. Randomization was stratified according to Child-Pugh status (A/B), performance status (ECOG 0/1), bilobar disease (yes/no), and prior curative treatment (yes/no). The primary endpoint was tumor response (EASL) at 6 months following independent, blinded review of MRI studies. The drug-eluting bead group showed higher rates of complete response, objective response, and disease control compared with the cTACE group (27% vs. 22%, 52% vs. 44%, and 63% vs. 52%, respectively). The hypothesis of superiority was not met (one-sided P = 0.11). However, patients with Child-Pugh B, ECOG 1, bilobar disease, and recurrent disease showed a significant increase in objective response (P = 0.038) compared to cTACE. DC Bead was associated with improved tolerability, with a significant reduction in serious liver toxicity (P < 0.001) and a significantly lower rate of doxorubicin-related side effects (P = 0.0001). TACE with DC Bead and doxorubicin is safe and effective in the treatment of HCC and offers a benefit to patients with more advanced disease.

  5. Elution of Clindamycin and Enrofloxacin From Calcium Sulfate Hemihydrate Beads In Vitro.

    Science.gov (United States)

    Phillips, Heidi; Boothe, Dawn M; Bennett, R Avery

    2015-11-01

    To compare the in vitro elution characteristics of clindamycin and enrofloxacin from calcium sulfate hemihydrate beads containing a single antibiotic, both antibiotics, and each antibiotic incubated in the same eluent well. Experimental in vitro study. Calcium sulfate hemihydrate beads were formed by mixing with clindamycin and/or enrofloxacin to create 4 study groups: (1) 160 mg clindamycin/10 beads; (2) 160 mg enrofloxacin/10 beads; (3) 160 mg clindamycin + 160 mg enrofloxacin/10 beads; and (4) 160 mg clindamycin/5 beads and 160 mg enrofloxacin/5 beads. Chains of beads were formed in triplicate and placed in 5 mL phosphate buffered saline (PBS; pH 7.4 and room temperature) with constant agitation. Antibiotic-conditioned PBS was sampled at 14 time points from 1 hour to 30 days. Clindamycin and enrofloxacin concentrations in PBS were determined using high-performance liquid chromatography. Eluent concentrations from clindamycin-impregnated beads failed to remain sufficiently above minimum inhibitory concentration (MIC) for common infecting bacteria over the study period. Enrofloxacin eluent concentrations remained sufficiently above MIC for common wound pathogens of dogs and cats and demonstrated an atypical biphasic release pattern. No significant differences in elution occurred as a result of copolymerization of the antibiotics into a single bead or from individual beads co-eluting in the same eluent well. Clindamycin-impregnated beads cannot be recommended for treatment of infection at the studied doses; however, use of enrofloxacin-impregnated beads may be justified when susceptible bacteria are cultured. © Copyright 2015 by The American College of Veterinary Surgeons.

  6. Towards Hypoxia-responsive Drug-eluting Embolization Beads.

    Science.gov (United States)

    Ashrafi, Koorosh; Heaysman, Clare L; Phillips, Gary J; Lloyd, Andrew W; Lewis, Andrew L

    2017-05-30

    Drug release from chemoembolization microspheres stimulated by the presence of a chemically reducing environment may provide benefits for targeting drug resistant and metastatic hypoxic tumours. A water-soluble disulfide-based bifunctional cross-linker bis(acryloyl)-(l)-cystine (BALC) was synthesised, characterised and incorporated into a modified poly(vinyl) alcohol (PVA) hydrogel beads at varying concentrations using reverse suspension polymerisation. The beads were characterised to confirm the amount of cross-linker within each formulation and its effects on the bead properties. Elemental and UV/visible spectroscopic analysis confirmed the incorporation of BALC within the beads and sizing studies showed that in the presence of a reducing agent, all bead formulations increased in mean diameter. The BALC beads could be loaded with doxorubicin hydrochloride and amounts in excess of 300mg of drug per mL of hydrated beads could be achieved but required conversion of the carboxylic acid groups of the BALC to their sodium carboxylate salt forms. Elution of doxorubicin from the beads demonstrated a controlled release via ionic exchange. Some formulations exhibited an increase in size and release of drug in the presence of a reducing agent, and therefore demonstrated the ability to respond to an in vitro reducing environment. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  7. Hepatic Arterial Chemoembolization Using Drug-Eluting Beads in Gastrointestinal Neuroendocrine Tumor Metastatic to the Liver

    International Nuclear Information System (INIS)

    Gaur, Shantanu K.; Friese, Jeremy L.; Sadow, Cheryl A.; Ayyagari, Rajasekhara; Binkert, Christoph A.; Schenker, Matthew P.; Kulke, Matthew; Baum, Richard

    2011-01-01

    Purpose: This study was designed to evaluate short ( 3 months) follow-up in patients with metastatic neuroendocrine tumor to the liver who underwent hepatic arterial chemoembolization with drug-eluting beads at a single institution. Methods: Institutional review board approval was obtained for this retrospective review. All patients who were treated with 100–300 or 300–500 μm drug-eluting LC Beads (Biocompatibles, UK) preloaded with doxorubicin (range, 50–100 mg) for GI neuroendocrine tumor metastatic to the liver from June 2004 to June 2009 were included. CT and MRI were evaluated for progression using Response Evaluation Criteria In Solid Tumors (RECIST) or European Association for the Study of the Liver (EASL) criteria. Short-term ( 3 months) imaging response was determined and Kaplan–Meier survival curves were plotted. Results: Thirty-eight drug-eluting bead chemoembolization procedures were performed on 32 hepatic lobes, comprising 21 treatment cycles in 18 patients. All procedures were technically successful with two major complications (biliary injuries). At short-term follow-up (<3 months), 22 of 38 (58%) procedures and 10 of 21 (48%) treatment cycles produced an objective response (OR) with the remainder having stable disease (SD). At intermediate-term follow-up (mean, 445 days; range, 163–1247), 17 of 26 (65%) procedures and 8 of 14 (57%) treatment cycles produced an OR. Probability of progressing was approximately 52% at 1 year with a median time to progression of 419 days. Conclusions: Drug-eluting bead chemoembolization is a reasonable alternative to hepatic arterial embolization and chemoembolization for the treatment of metastatic neuroendocrine tumor to the liver.

  8. Response rates of hepatocellular carcinoma and hepatic colorectal cancer metastases to drug eluting bead regional liver therapy

    Institute of Scientific and Technical Information of China (English)

    Glenn W. Stambo; Deborah Cragan

    2017-01-01

    Aim: The purpose of this study was to evaluate and compare how hepatocellular carcinoma (HCC) and colorectal metastases respond to LC Bead chemoembolization using doxorubicin and irinotecan. Methods: The authors report their experience with doxorubicin and irinotecan eluting beads to treat 13 patients with primary HCC and 25 patients with colorectal metastases over a 1-year period at a single community based oncology practice. Within the colorectal cancer group they compared irinotecan eluting beads to doxorubicin eluting beads. Results:Nine of the 11 (81.8%) doxorubicin treated HCC patients had either complete response or partial response. All of the HCC lesions showed reduction in size and tumor enhancement and 10/11 (91%) HCC patients were alive at 24 months post treatment. Fisher's exact test revealed that among the 22 with colorectal metastases for whom follow-up data were available, those 11 who were treated with doxorubicin were significantly more likely to demonstrate complete or partial response compared to the 11 in the irinotecan treated group (P < 0.001). Conclusion:Overall, HCC and colon metastasis patients clearly demonstrated the effectiveness of drug eluting beads with 91% of the HCC patients alive 24 months after treatment.

  9. Bradycardia Associated With Drug-Eluting Beads Loaded With Irinotecan (DEBIRI) Infusion for Colorectal Liver Metastases

    International Nuclear Information System (INIS)

    Pua, Uei

    2013-01-01

    Intra-arterial injection of drug-eluting beads loaded with irinotecan (DEBIRI) is a new treatment option being investigated, with encouraging results, for unresectable colorectal liver metastases that are refractory to systemic chemotherapy (Martin et al., Ann Surg Oncol 18:192–198, 2011). Toxicity related to DEBIRI has also been described (Martin et al., Cardiovasc Intervent Radiol 33:960–966, 2010). Nevertheless, experience and literature related to DEBIRI remain limited, and experience with this treatment is expected to increase. The purpose of this article is to describe bradycardia occurring during DEBIRI administration, which has not been reported thus far.

  10. Bradycardia Associated With Drug-Eluting Beads Loaded With Irinotecan (DEBIRI) Infusion for Colorectal Liver Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei, E-mail: druei@yahoo.com [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore)

    2013-06-15

    Intra-arterial injection of drug-eluting beads loaded with irinotecan (DEBIRI) is a new treatment option being investigated, with encouraging results, for unresectable colorectal liver metastases that are refractory to systemic chemotherapy (Martin et al., Ann Surg Oncol 18:192-198, 2011). Toxicity related to DEBIRI has also been described (Martin et al., Cardiovasc Intervent Radiol 33:960-966, 2010). Nevertheless, experience and literature related to DEBIRI remain limited, and experience with this treatment is expected to increase. The purpose of this article is to describe bradycardia occurring during DEBIRI administration, which has not been reported thus far.

  11. A simple elution strategy for biotinylated proteins bound to streptavidin conjugated beads using excess biotin and heat.

    Science.gov (United States)

    Cheah, Joleen S; Yamada, Soichiro

    2017-12-02

    Protein-protein interactions are the molecular basis of cell signaling. Recently, proximity based biotin identification (BioID) has emerged as an alternative approach to traditional co-immunoprecipitation. In this protocol, a mutant biotin ligase promiscuously labels proximal binding partners with biotin, and resulting biotinylated proteins are purified using streptavidin conjugated beads. This approach does not require preservation of protein complexes in vitro, making it an ideal approach to identify transient or weak protein complexes. However, due to the high affinity bond between streptavidin and biotin, elution of biotinylated proteins from streptavidin conjugated beads requires harsh denaturing conditions, which are often incompatible with downstream processing. To effectively release biotinylated proteins bound to streptavidin conjugated beads, we designed a series of experiments to determine optimal binding and elution conditions. Interestingly, the concentrations of SDS and IGEPAL-CA630 during the incubation with streptavidin conjugated beads were the key to effective elution of biotinylated proteins using excess biotin and heating. This protocol provides an alternative method to isolate biotinylated proteins from streptavidin conjugated beads that is suitable for further downstream analysis. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Sustained multiple organ ischaemia after transarterial chemoembolization with drug-eluting beads for hepatocellular carcinoma.

    Science.gov (United States)

    Kim, Young Woon; Kwon, Jung Hyun; Nam, Soon Woo; Jang, Jeong Won; Jung, Hyun Suk; Shin, Yu Ri; Park, Eun Su; Shim, Dong Jae

    2018-02-01

    Transarterial chemoembolization (TACE) with drug-eluting beads (DC beads) may enhance drug delivery to tumours and reduce systemic toxicity. TACE with DC beads leads to significantly fewer serious side-effects compared with conventional TACE. A 66-year-old man with hepatocellular carcinoma (HCC) complained of continuous abdominal pain 1 month after TACE with DC beads. At the time of TACE, angiography revealed severe stenosis of both hepatic arteries. The diagnostic work up on admission suggested severe bile duct injury with regional bile duct dilatation, segmental liver and spleen infarction, necrotizing pancreatitis, as well as gastric and duodenal ulcers. The pathology specimens of the duodenum contained DC beads that had passed through small vessels in the connective tissue. The patient's condition appeared to improve after 2 weeks of antibiotic treatment and supportive care, but new multifocal liver and spleen infarction subsequently developed. After 2 months, he was well enough to be discharged. His HCC partially responded to the TACE with DC beads but eventually progressed and he died after 11 months. The present case report highlights unexpected ongoing multiple organ ischaemia in a 66-year-old man treated for HCC using TACE with DC beads. The use of TACE with DC beads should be carefully considered in patients with vascular strictures or aberrant blood supply.

  13. Transarterial chemoembolization with drug-eluting beads for hepatocellular carcinoma: its research progress

    International Nuclear Information System (INIS)

    Zhao Yan; Han Guohong; Bai Wei; Fan Daiming

    2012-01-01

    Transarterial chemoembolization (TACE) has been the main treatment for patients with intermediate-stage hepatocellular carcinoma (HCC). However, the clinical application of TACE is limited due to the technical deficiencies, such as uncontrolled local drug delivery and systemic toxicity. Recently, the new drug-eluting beads (DEB), loading with doxorubicin, have be used in the TACE procedures. This new technique can not only maintain the local drug level for quite a long time and thus get a higher objective response, but also decrease the systemic toxicity. Transarterial chemoembolization with drug-eluting beads (DEB-TACE) have already been widely used abroad, and more related clinical trials are underway to clarify its advantages. This paper aims to make a comprehensive review in the respects of its characteristics and the latest research progress in DEB-TACE. (authors)

  14. Posterior reversible leukoencephalopathy syndrome secondary to hepatic transarterial chemoembolization with doxorubicin drug eluting beads

    Science.gov (United States)

    Kistler, C. Andrew; McCall, Joseph Caleb; Ghumman, Saad Sultan; Ali, Ijlal Akbar

    2014-01-01

    Posterior reversible encephalopathy syndrome (PRES) is a rare complication of transarterial chemoembolization (TACE) used to treat liver metastases and has never been reported in a patient with metastatic uveal melanoma (UM) to the liver. We report the first case of PRES secondary to TACE with drug eluting beads (DEBs) loaded with doxorubicin in a 56-year-old woman with metastatic UM to the liver. PMID:24772346

  15. Small Versus Large-Sized Drug-Eluting Beads (DEBIRI) for the Treatment of Hepatic Colorectal Metastases: A Propensity Score Matching Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Akinwande, Olaguoke K., E-mail: gokeakin@gmail.com [University of Louisville Hospital, Department of Interventional Radiology (United States); Philips, Prejesh, E-mail: prejesh.philips@louisville.edu [University of Louisville, Division of Surgical Oncology, Department of Surgery (United States); Duras, Petr, E-mail: durasp@seznam.cz [Fakultní nemocnice Plzeň (Czech Republic); Pluntke, Stefan, E-mail: stefan.pluntke@t-online.de [Onkologe bei Kliniken Essen-Mitte (Germany); Scoggins, Charles, E-mail: charles.scoggins@louisville.edu; Martin, Robert C. G., E-mail: Robert.Martin@louisville.edu [University of Louisville, Division of Surgical Oncology, Department of Surgery (United States)

    2015-04-15

    PurposeTo compare the feasibility, safety, and efficacy with small and large irinotecan drug-eluting beads (DEBIRI) for treating hepatic colorectal metastases.MethodsUsing our prospectively maintained, multi-center, intra-arterial therapy registry, we identified 196 patients treated with a combination of large beads (100–300 to 500–700 μm) and patients treated with a combination of small beads (70–150 to 100–300 μm). To minimize selection bias, a propensity score analysis was performed to compare both groups.ResultsUnadjusted analysis consisted of 196 and 30 patients treated with large and small beads, respectively. The adjusted analysis consisted of 19 patients each. Unadjusted analysis showed decreased all-grade (p = <0.001) and high-grade adverse effects (p = 0.02) in the small bead group, with a persisting trend toward decreased overall side effects in the adjusted analysis favoring small beads (p = 0.09) The adjusted analysis showed the percentage dose delivered (delivered dose/intended dose) was significantly greater in the small bead group compared to the large bead group (96 vs 79 %; p = 0.005). There were also a lower percentage of treatments terminating in complete stasis in the adjusted analysis (0.0035). Adjusted analysis also showed increased objective response rate (ORR) at 12 months (p = 0.04), with a corresponding trend also seen in the unadjusted analysis (0.09).ConclusionSmaller beads result in increased dose delivery probably due to less propensity to reach complete stasis. It may also lead to more durable long-term efficacy. Smaller beads also demonstrate similarly low toxicity compared to large-sized beads with a trend toward less toxicity.

  16. Small Versus Large-Sized Drug-Eluting Beads (DEBIRI) for the Treatment of Hepatic Colorectal Metastases: A Propensity Score Matching Analysis

    International Nuclear Information System (INIS)

    Akinwande, Olaguoke K.; Philips, Prejesh; Duras, Petr; Pluntke, Stefan; Scoggins, Charles; Martin, Robert C. G.

    2015-01-01

    PurposeTo compare the feasibility, safety, and efficacy with small and large irinotecan drug-eluting beads (DEBIRI) for treating hepatic colorectal metastases.MethodsUsing our prospectively maintained, multi-center, intra-arterial therapy registry, we identified 196 patients treated with a combination of large beads (100–300 to 500–700 μm) and patients treated with a combination of small beads (70–150 to 100–300 μm). To minimize selection bias, a propensity score analysis was performed to compare both groups.ResultsUnadjusted analysis consisted of 196 and 30 patients treated with large and small beads, respectively. The adjusted analysis consisted of 19 patients each. Unadjusted analysis showed decreased all-grade (p = <0.001) and high-grade adverse effects (p = 0.02) in the small bead group, with a persisting trend toward decreased overall side effects in the adjusted analysis favoring small beads (p = 0.09) The adjusted analysis showed the percentage dose delivered (delivered dose/intended dose) was significantly greater in the small bead group compared to the large bead group (96 vs 79 %; p = 0.005). There were also a lower percentage of treatments terminating in complete stasis in the adjusted analysis (0.0035). Adjusted analysis also showed increased objective response rate (ORR) at 12 months (p = 0.04), with a corresponding trend also seen in the unadjusted analysis (0.09).ConclusionSmaller beads result in increased dose delivery probably due to less propensity to reach complete stasis. It may also lead to more durable long-term efficacy. Smaller beads also demonstrate similarly low toxicity compared to large-sized beads with a trend toward less toxicity

  17. Irinotecan drug eluting beads used as a treatment of advanced intra hepatic cholangiocarcinoma

    Directory of Open Access Journals (Sweden)

    Jean Amede Roch

    2008-10-01

    Full Text Available

    This report describes a 74-year-old male with unresectable intrahepatic cholangiocarcinoma (ICC. However surgical procedure is the only curative treatment, it often seems to be ineffective because of the aggressive behaviour of the disease. The role of systemic chemotherapy in the ICC is undefined with a median survival between 6.43 to 12.17 months obtained by using the combination chemotherapy of gemcitabine with cisplatin. In the present case, we performed a targeted treatment using drug eluting beads (DEB with irinotecan (IRI administered as transarterial-chemoembolization (TACE. After one session, the tumour vascularity decreased significantly at the one month evaluation on computed tomography (CT scan of the liver.  This case report suggested that minimally invasive transcatheter DEB embolization could be a promising, safe and effective treatment for selective patients with unresectable ICC.

  18. In vitro biologic efficacy of sunitinib drug-eluting beads on human colorectal and hepatocellular carcinoma-A pilot study.

    Directory of Open Access Journals (Sweden)

    Steven Lahti

    Full Text Available Sunitinib drug eluting beads (DEB are a novel anti-angiogenic bead preparation for use in transarterial chemoembolization. However, systematic studies of sunitinib DEB's effect on cancer cells have not been reported. Herein, we assess their direct biologic efficacy against carcinoma cell lines and correlate cell viability with drug release in vitro.Sunitinib-HCl (10mg/mL in Milli-Q water was mixed with LC Bead® 300-500μm (Biocompatibles UK Ltd.. Loading and release were assessed by measurement of drug UV absorbance using UV-visible spectrophotometer. Viability of human colorectal cancer (CRC, HCT116 and HT29 and hepatocellular carcinoma (HCC, HepG2 cells upon exposure to sunitinib DEB was measured using a bioluminescent assay. Drug concentration during exposure was quantified using HPLC.When added to cultured HepG2 cells, sunitinib DEB rapidly inhibited viability with a significant decrease observed within 1 hour of incubation. Viability of HCT116 and HT29 cells decreased relatively slower, with significant reductions observed after 8 and 24 hours, respectively. After 24 hours there was nearly complete inhibition of all three cell lines. There was no difference in viability observed between cells treated with 5 μl, 10 μL, or 20 μL of sunitinib DEB. HPLC analysis of the cell culture supernatant demonstrated saturation of the cell medium within approximately 4 hours for each amount added, with sunitinib achieving a final concentration of 17.61 μM (SE ±1.01.Sunitinib can be efficiently loaded to and released from LC beads, and the resulting sunitinib DEB demonstrate strong in vitro inhibition of human CRC and HCC cells.

  19. Histological assessment of the efficacy of drug-eluting beads in portal tumor thrombosis of hepatocellular carcinoma

    Directory of Open Access Journals (Sweden)

    Yusuke Imai, MD

    2017-03-01

    Full Text Available A 58-year-old man was diagnosed with advanced hepatocellular carcinoma with portal vein tumor thrombosis (PVTT. The tumors were multiple and existed in both lobes. Drug-eluting beads transcatheter arterial chemoembolization (DEB-TACE was performed for the tumors in the left lobe. Embosphere and Hepasphere were selected for embolization of the arterioportal shunt, followed by loaded epirubicin infusion into the left hepatic artery. Computed tomography showed reduction of PVTT. However, liver failure progressed, and the patient died 67 days after DEB-TACE. Autopsy showed that the beads reached the tumor thrombosis in the portal vein. The prognosis of hepatocellular carcinoma with PVTT is poor. Although there are no established treatments for unresectable PVTT, DEB-TACE might be a useful option for such cases.

  20. Unenhanced and Contrast-Enhanced Ultrasonography During Hepatic Transarterial Embolization and Chemoembolization With Drug-Eluting Beads

    International Nuclear Information System (INIS)

    Moschouris, Hippocrates; Malagari, Katerina; Kornezos, Ioannis; Papadaki, Marina Georgiou; Gkoutzios, Panagiotis; Matsaidonis, Dimitrios

    2010-01-01

    The purpose of this study was to describe and evaluate the findings of unenhanced ultrasonography (US) and contrast-enhanced ultrasonography (CEUS) when these modalities are applied during transarterial embolization (TAE) or transarterial chemoembolization (TACE) of liver tumors. Sixteen tumors (9 hepatocellular carcinomas, 5 metastases from colorectal cancer, and 2 hemangiomas) were treated with TAE with microspheres and/or TACE with drug-eluting beads. All of these lesions were studied with intraprocedural unenhanced US and 12 were studied with intraprocedural CEUS. For the latter, a second-generation echo-enhancer (SonoVue; Bracco, Milan, Italy) and a low mechanical index technique were used. Intraprocedural findings were classified according to an arbitrary scale and were compared with pretreatment imaging (CEUS and computed tomography or CEUS and magnetic resonance imaging), with postembolization angiography, and with follow-up results. On unenhanced intraprocedural US, 13 of 16 tumors demonstrated intralesional high-level echoes of varying extent. These feature correlated poorly (r = 0.33, p = 0.097) with and generally underestimated the actual extent of necrosis. Exceptionally, high-level echoes that occupied the largest part of the treated lesions were associated with >50% tumor necrosis. Intraprocedural CEUS clearly depicted immediate partial or complete disappearance of tumor enhancement as a result of TAE/TACE. Three of 6 tumors with complete devascularization on postembolization angiogram showed residual enhancement on intraprocedural CEUS. Intraprocedural CEUS findings correlated closely (r = 0.91, p = 0.002) with follow-up findings. Intraprocedural sonography, particularly with echo-enhancers, could be used for intraprocedural monitoring in selected cases of liver tumors that undergo TAE or TACE.

  1. Beads.

    Science.gov (United States)

    Weewish Tree, 1979

    1979-01-01

    Beads served both as ornaments and as a medium of exchange, and the Indians manufactured them from such natural sources as bones, stones, beans, nuts, animal teeth, and polished antlers. Even after the introduction of European glass beads, the Indians continued to make their favorite beads from the natural sources. (DS)

  2. Chemoembolization With Doxorubicin-Eluting Beads for Unresectable Hepatocellular Carcinoma: Five-Year Survival Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Malagari, Katerina, E-mail: kmalag@otonet.gr [University of Athens, Second Department of Radiology (Greece); Pomoni, Mary [University of Athens, Imaging and Research Unit (Greece); Moschouris, Hippocrates, E-mail: hipmosch@gmail.com [Tzanion Hospital, Department of Radiology (Greece); Bouma, Evanthia [University of Athens, Imaging and Research Unit (Greece); Koskinas, John [Ippokration Hospital, University of Athens, Department of Internal Medicine and Hepatology (Greece); Stefaniotou, Aspasia [University of Athens, Imaging and Research Unit (Greece); Marinis, Athanasios [Tzanion Hospital, Department of Surgery (Greece); Kelekis, Alexios; Alexopoulou, Efthymia [University of Athens, Second Department of Radiology (Greece); Chatziioannou, Achilles [University of Athens, First Department of Radiology (Greece); Chatzimichael, Katerina [University of Athens, Second Department of Radiology (Greece); Dourakis, Spyridon [Ippokration Hospital, University of Athens, Department of Internal Medicine and Hepatology (Greece); Kelekis, Nikolaos [University of Athens, Second Department of Radiology (Greece); Rizos, Spyros [Tzanion Hospital, Department of Surgery (Greece); Kelekis, Dimitrios [University of Athens, Imaging and Research Unit (Greece)

    2012-10-15

    Purpose: The purpose of this study was to report on the 5-year survival of hepatocellular carcinoma (HCC) patients treated with DC Bead loaded with doxorubicin (DEB-DOX) in a scheduled scheme in up to three treatments and thereafter on demand. Materials and Methods: 173 HCC patients not suitable for curable treatments were prospectively enrolled (mean age 70.4 {+-} 7.4 years). Child-Pugh (Child) class was A/B (102/71 [59/41 %]), Okuda stage was 0/1/2 (91/61/19 [53.2/35.7/11.1 %]), and mean lesion diameter was 7.6 {+-} 2.1 cm. Lesion morphology was one dominant {<=}5 cm (22 %), one dominant >5 cm (41.6 %), multifocal {<=}5 (26 %), and multifocal >5 (10.4 %). Results: Overall survival at 1, 2, 3, 4, and 5 years was 93.6, 83.8, 62, 41.04, and 22.5 %, with higher rates achieved in Child class A compared with Child class B patients (95, 88.2, 61.7, 45, and 29.4 % vs. 91.5, 75, 50.7, 35.2, and 12.8 %). Mean overall survival was 43.8 months (range 1.2-64.8). Cumulative survival was better for Child class A compared with Child class B patients (p = 0.029). For patients with dominant lesions {<=}5 cm 1-, 2-, 3-, 4-, and 5-year survival rates were 100, 95.2, 71.4, 66.6, and 47.6 % for Child class A and 94.1, 88.2, 58.8, 41.2, 29.4, and 23.5 % for Child class B patients. Regarding DEB-DOX treatment, multivariate analysis identified number of lesions (p = 0.033), lesion vascularity (p < 0.0001), initially achieved complete response (p < 0.0001), and objective response (p = 0.046) as significant and independent determinants of 5-year survival. Conclusion: DEB-DOX results, with high rates of 5-year survival for patients, not amenable to curative treatments. Number of lesions, lesion vascularity, and local response were significant independent determinants of 5-year survival.

  3. Chemoembolization With Doxorubicin-Eluting Beads for Unresectable Hepatocellular Carcinoma: Five-Year Survival Analysis

    International Nuclear Information System (INIS)

    Malagari, Katerina; Pomoni, Mary; Moschouris, Hippocrates; Bouma, Evanthia; Koskinas, John; Stefaniotou, Aspasia; Marinis, Athanasios; Kelekis, Alexios; Alexopoulou, Efthymia; Chatziioannou, Achilles; Chatzimichael, Katerina; Dourakis, Spyridon; Kelekis, Nikolaos; Rizos, Spyros; Kelekis, Dimitrios

    2012-01-01

    Purpose: The purpose of this study was to report on the 5-year survival of hepatocellular carcinoma (HCC) patients treated with DC Bead loaded with doxorubicin (DEB-DOX) in a scheduled scheme in up to three treatments and thereafter on demand. Materials and Methods: 173 HCC patients not suitable for curable treatments were prospectively enrolled (mean age 70.4 ± 7.4 years). Child-Pugh (Child) class was A/B (102/71 [59/41 %]), Okuda stage was 0/1/2 (91/61/19 [53.2/35.7/11.1 %]), and mean lesion diameter was 7.6 ± 2.1 cm. Lesion morphology was one dominant ≤5 cm (22 %), one dominant >5 cm (41.6 %), multifocal ≤5 (26 %), and multifocal >5 (10.4 %). Results: Overall survival at 1, 2, 3, 4, and 5 years was 93.6, 83.8, 62, 41.04, and 22.5 %, with higher rates achieved in Child class A compared with Child class B patients (95, 88.2, 61.7, 45, and 29.4 % vs. 91.5, 75, 50.7, 35.2, and 12.8 %). Mean overall survival was 43.8 months (range 1.2–64.8). Cumulative survival was better for Child class A compared with Child class B patients (p = 0.029). For patients with dominant lesions ≤5 cm 1-, 2-, 3-, 4-, and 5-year survival rates were 100, 95.2, 71.4, 66.6, and 47.6 % for Child class A and 94.1, 88.2, 58.8, 41.2, 29.4, and 23.5 % for Child class B patients. Regarding DEB-DOX treatment, multivariate analysis identified number of lesions (p = 0.033), lesion vascularity (p < 0.0001), initially achieved complete response (p < 0.0001), and objective response (p = 0.046) as significant and independent determinants of 5-year survival. Conclusion: DEB-DOX results, with high rates of 5-year survival for patients, not amenable to curative treatments. Number of lesions, lesion vascularity, and local response were significant independent determinants of 5-year survival.

  4. Liver and biliary damages following transarterial chemoembolization of hepatocellular carcinoma: comparison between drug-eluting beads and lipiodol emulsion

    Energy Technology Data Exchange (ETDEWEB)

    Monier, Arnaud; Duran, Rafael; Bize, Pierre; Dunet, Vincent; Denys, Alban [Lausanne University Hospital, Department of Diagnostic and Interventional Radiology, Lausanne (Switzerland); Guiu, Boris [Lausanne University Hospital, Department of Diagnostic and Interventional Radiology, Lausanne (Switzerland); Montpellier University Hospital, Department of Diagnostic and Interventional Radiology, Montpellier (France); Aho, Serge [University Hospital, Department of Epidemiology, Dijon (France); Deltenre, Pierre [Lausanne University Hospital, Department of Gastroenterology, Lausanne (Switzerland)

    2017-04-15

    To compare transarterial chemoembolization (TACE)-related hepatic toxicities of conventional TACE (cTACE) and drug-eluting beads TACE (DEB-TACE) in patients with intermediate-stage hepatocellular carcinoma. In this retrospective study, 151 consecutive patients undergoing cTACE or DEB-TACE and MRI 3-6 weeks before and after therapy were included. Toxicity was assessed on imaging (global hepatic damages (GHD), overall biliary injuries, biliary cast, bile duct dilatation, intrahepatic biloma, portal thrombosis), and clinico-biological follow-ups. Tumour response, time to progression (TTP), and overall survival were assessed. Factors influencing complication rate were identified by generalized equation logistic regression model. Biliary injuries and intrahepatic biloma incidence were significantly higher following DEB-TACE (p < 0.001). DEB-TACE showed a significant increased risk of GHD (OR: 3.13 [1.74-5.63], p < 0.001) and biliary injuries (OR: 4.53 [2.37-8.67], p < 0.001). A significant relationship was found between baseline prothrombin value and GHD, biliary injuries and intrahepatic biloma (all p < 0.01), and between the dose of chemotherapy and intrahepatic biloma (p = 0.001). Only TTP was significantly shorter following DEB-TACE compared to cTACE (p = 0.025). DEB-TACE was associated with increased hepatic toxicities compared to cTACE. GHD, biliary injuries, and intrahepatic biloma were more frequently observed with high baseline prothrombin value, suggesting that cTACE might be more appropriate than DEB-TACE in patients with less advanced cirrhosis. (orig.)

  5. Phase II Study of Chemoembolization With Drug-Eluting Beads in Patients With Hepatic Neuroendocrine Metastases: High Incidence of Biliary Injury

    Energy Technology Data Exchange (ETDEWEB)

    Bhagat, Nikhil, E-mail: nbhagat1@jhmi.edu; Reyes, Diane K., E-mail: dreyes@jhmi.edu [Johns Hopkins University Medical Center, Johns Hopkins Hospital, Division of Vascular and Interventional Radiology, Department of Radiology (United States); Lin, Mingde, E-mail: ming.lin@philips.com [Philips Research North America, Clinical Informatics, Interventional, and Translational Solutions (CIITS) (United States); Kamel, Ihab [Johns Hopkins University Medical Center, Johns Hopkins Hospital, Division of Vascular and Interventional Radiology, Department of Radiology (United States); Pawlik, Timothy M. [Johns Hopkins University Medical Center, Department of Surgery (United States); Frangakis, Constantine, E-mail: cfrangak@jhsph.edu [Johns Hopkins University, Department of Biostatistics, Bloomberg School of Public Health (United States); Geschwind, J. F., E-mail: jfg@jhmi.edu [Johns Hopkins University Medical Center, Johns Hopkins Hospital, Division of Vascular and Interventional Radiology, Department of Radiology (United States)

    2013-04-15

    To evaluate safety in an interim analysis of transarterial chemoembolization (TACE) with doxorubicin-eluting beads (DEB) in 13 patients with hepatic metastases from neuroendocrine tumors (NETs) as part of a phase II trial. Institutional Review Board approval and informed consent were obtained. Thirteen patients completed preliminary safety analysis. Their mean age was 65 years, Eastern Cooperative Oncology Group status was 0/1, tumor burden range was 4-75 %, and mean targeted tumor size was 5.9 cm. Up to four DEB-TACE sessions (100-300 {mu}m beads loaded with {<=}100 mg doxorubicin) within 6 months were allowed. Tumor response was assessed by magnetic resonance imaging 1 month after treatment using contrast-enhancement [European Association for the Study of the Liver (EASL) and size Response Evaluation Criteria in Solid Tumors (RECIST)] criteria. Safety was assessed by National Cancer Institute Common Terminology Criteria. DEB-TACE was successfully performed in all 13 patients. At 1 month follow-up, there was a mean 12 % decrease in tumor size (p < 0.0003) and a 56 % decrease in tumor enhancement (p < 0.0001). By EASL criteria, the targeted lesion objective response rate was 78 %. Grade 3 to 4 toxicities were fatigue (23 %), increased alanine amino transferase (15 %), hyperglycemia (15 %), and abdominal pain (8 %). Seven patients developed bilomas (54 %); all of these patients had multiple small (<4 cm) lesions. Subsequently, four underwent percutaneous drainage, three for abscess formation and one for symptoms related to mass effect. Although biloma and liver abscess are known risks after TACE, the high incidence in our study population was unexpected and forced interruption of the trial. Although this occurred in a small group of patients, we have changed our technique and patient selection as a result of these findings, thus allowing resumption of the trial.

  6. Phase II Study of Chemoembolization With Drug-Eluting Beads in Patients With Hepatic Neuroendocrine Metastases: High Incidence of Biliary Injury

    International Nuclear Information System (INIS)

    Bhagat, Nikhil; Reyes, Diane K.; Lin, Mingde; Kamel, Ihab; Pawlik, Timothy M.; Frangakis, Constantine; Geschwind, J. F.

    2013-01-01

    To evaluate safety in an interim analysis of transarterial chemoembolization (TACE) with doxorubicin-eluting beads (DEB) in 13 patients with hepatic metastases from neuroendocrine tumors (NETs) as part of a phase II trial. Institutional Review Board approval and informed consent were obtained. Thirteen patients completed preliminary safety analysis. Their mean age was 65 years, Eastern Cooperative Oncology Group status was 0/1, tumor burden range was 4–75 %, and mean targeted tumor size was 5.9 cm. Up to four DEB-TACE sessions (100–300 μm beads loaded with ≤100 mg doxorubicin) within 6 months were allowed. Tumor response was assessed by magnetic resonance imaging 1 month after treatment using contrast-enhancement [European Association for the Study of the Liver (EASL) and size Response Evaluation Criteria in Solid Tumors (RECIST)] criteria. Safety was assessed by National Cancer Institute Common Terminology Criteria. DEB-TACE was successfully performed in all 13 patients. At 1 month follow-up, there was a mean 12 % decrease in tumor size (p < 0.0003) and a 56 % decrease in tumor enhancement (p < 0.0001). By EASL criteria, the targeted lesion objective response rate was 78 %. Grade 3 to 4 toxicities were fatigue (23 %), increased alanine amino transferase (15 %), hyperglycemia (15 %), and abdominal pain (8 %). Seven patients developed bilomas (54 %); all of these patients had multiple small (<4 cm) lesions. Subsequently, four underwent percutaneous drainage, three for abscess formation and one for symptoms related to mass effect. Although biloma and liver abscess are known risks after TACE, the high incidence in our study population was unexpected and forced interruption of the trial. Although this occurred in a small group of patients, we have changed our technique and patient selection as a result of these findings, thus allowing resumption of the trial.

  7. Contrast-Enhanced Ultrasonography of Hepatocellular Carcinoma After Chemoembolisation Using Drug-Eluting Beads: A Pilot Study Focused on Sustained Tumor Necrosis

    International Nuclear Information System (INIS)

    Moschouris, Hippocrates; Malagari, Katerina; Papadaki, Marina Georgiou; Kornezos, Ioannis; Matsaidonis, Dimitrios

    2010-01-01

    The purpose of this study was to assess the use of contrast-enhanced ultrasonography (CEUS) and the sustained antitumor effect of drug-eluting beads used for transarterial chemoembolisation (TACE) of unresectable hepatocellular carcinoma (HCC). Ten patients with solitary, unresectable HCC underwent CEUS before, 2 days after, and 35 to 40 days after TACE using a standard dose (4 ml) of drug-eluting beads (DC Beads; Biocompatibles, Surrey, UK) preloaded with doxorubicin (25 mg doxorubicin/ml hydrated beads). For CEUS, a second-generation contrast agent (SonoVue, Bracco, Milan, Italy) and a low mechanical-index technique were used. A part of the tumor was characterized as necrotic if it showed complete lack of enhancement. The percentage of necrosis was calculated at the sonographic section that depicted the largest diameter of the tumor. Differences in the extent of early (2 days after TACE) and delayed (35 to 40 days after TACE) necrosis were quantitatively and subjectively assessed. Early post-TACE tumor necrosis ranged from 21% to 70% (mean 43.5% ± 19%). There was a statistically significant (p = 0.0012, paired Student t test) higher percentage of delayed tumor necrosis, which ranged from 24% to 88% (mean 52.3% ± 20.3%). Subjective evaluation showed a delayed obvious increase of the necrotic areas in 5 patients. In 2 patients, tumor vessels that initially remained patent disappeared on the delayed follow-up. A part of tumor necrosis after chemoembolisation of HCC with DEB seems to take place later than 2 days after TACE. CEUS may provide evidence for the sustained antitumor effect of DEB-TACE. Nevertheless, the ideal time for the imaging evaluation of tumor response remains to be defined.

  8. An on-line monitor for cation exchange elution chromatography using lithium silicate glass beads as solid scintillator

    International Nuclear Information System (INIS)

    Zhu Rongbao; Yang Liucheng; Wei Liansheng; Ji Liqiang; Zhang Zengrui

    1988-03-01

    A new type of on-line monitoring system used to monitor radioactive nuclides with α or soft β radiation in the effluent from a high pressure ion exchange column is described. The beads made of cerium-impregnated lithium silicate glass are used as scientillation material. They are filled into a quartz glass tube to form a flow cell. By reducing the diameter of glass beads to more closly approximate the average range of α or soft β radiation in solution, the absolute counting efficiency for 241 Am, 242 Cm α radiation have reached and 85.8% and 92.8% respectively, for 14 C, 90 Sr- 90 Y β radiation, 62.1% and 88.6% respectively. These values can be comparable to those achieved with on-line liquid scientillation technique. When the total amount of 241 Am added into column is decreased to 7.4 Bq it is still possible to obtain a clear chromatography peak (half peak width = 0.22 mL)

  9. 2-year clinical outcomes after implantation of sirolimus-eluting, paclitaxel-eluting, and bare-metal coronary stents: results from the WDHR (Western Denmark Heart Registry)

    DEFF Research Database (Denmark)

    Kaltoft, Anne; Jensen, Lisette Okkels; Maeng, Michael

    2009-01-01

    OBJECTIVES: This registry study assessed the safety and efficacy of the 2 types of drug-eluting stents (DES), sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES), compared with bare-metal stents (BMS). BACKGROUND: Drug-eluting stents may increase the risk of stent thrombosis (ST...... databases. We used Cox regression analysis to control for confounding. RESULTS: The 2-year incidence of definite ST was 0.64% in BMS patients, 0.79% in DES patients (adjusted relative risk [RR]: 1.09; 95% confidence interval [CI]: 0.72 to 1.65), 0.50% in SES patients (adjusted RR: 0.63, 95% CI: 0.35 to 1...

  10. Meta-analysis: adjusted indirect comparison of drug-eluting bead transarterial chemoembolization versus 90Y-radioembolization for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Ludwig, Johannes M.; Xing, Minzhi; Zhang, Di; Kim, Hyun S.

    2017-01-01

    To investigate comparative effectiveness of drug-eluting bead transarterial chemoembolization (DEB-TACE) versus Yttrium-90 ( 90 Y)-radioembolization for hepatocellular carcinoma (HCC). Studies comparing conventional (c)TACE versus 90 Y-radioembolization or DEB-TACE for HCC treatment were identified using PubMed/Medline, Embase, and Cochrane databases. The adjusted indirect meta-analytic method for effectiveness comparison of DEB-TACE versus 90 Y-radioembolization was used. Wilcoxon rank-sum test was used to compare baseline characteristics. A priori defined sensitivity analysis of stratified study subgroups was performed for primary outcome analyses. Publication bias was tested by Egger's and Begg's tests. Fourteen studies comparing DEB-TACE or 90 Y-radioembolization with cTACE were included. Analysis revealed a 1-year overall survival benefit for DEB-TACE over 90 Y-radioembolization (79 % vs. 54.8 %; OR: 0.57; 95 %CI: 0.355-0.915; p = 0.02; I-squared: 0 %; p > 0.5), but not for the 2-year (61 % vs. 34 %; OR: 0.65; 95%CI: 0.294-1.437; p = 0.29) and 3-year survival (56.4 % vs. 20.9 %; OR: 0.713; 95 % CI: 0.21-2.548; p = 0.62). There was significant heterogeneity in the 2- and 3-year survival analyses. The pooled median overall survival was longer for DEB-TACE (22.6 vs. 14.7 months). There was no significant difference in tumour response rate. DEB-TACE and 90 Y-radioembolization are efficacious treatments for patients suffering from HCC; DEB-TACE demonstrated survival benefit at 1-year compared to 90 Y-radioembolization but direct comparison is warranted for further evaluation. (orig.)

  11. Meta-analysis: adjusted indirect comparison of drug-eluting bead transarterial chemoembolization versus {sup 90}Y-radioembolization for hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Ludwig, Johannes M.; Xing, Minzhi [Yale School of Medicine, Division of Interventional Radiology, Department of Radiology and Biomedical Imaging, New Haven, CT (United States); Zhang, Di [University of Pittsburgh Graduate School of Public Health, Department of Biostatistics, Pittsburgh, PA (United States); Kim, Hyun S. [Yale School of Medicine, Division of Interventional Radiology, Department of Radiology and Biomedical Imaging, New Haven, CT (United States); Yale School of Medicine, Yale Cancer Center, New Haven, CT (United States)

    2017-05-15

    To investigate comparative effectiveness of drug-eluting bead transarterial chemoembolization (DEB-TACE) versus Yttrium-90 ({sup 90}Y)-radioembolization for hepatocellular carcinoma (HCC). Studies comparing conventional (c)TACE versus {sup 90}Y-radioembolization or DEB-TACE for HCC treatment were identified using PubMed/Medline, Embase, and Cochrane databases. The adjusted indirect meta-analytic method for effectiveness comparison of DEB-TACE versus {sup 90}Y-radioembolization was used. Wilcoxon rank-sum test was used to compare baseline characteristics. A priori defined sensitivity analysis of stratified study subgroups was performed for primary outcome analyses. Publication bias was tested by Egger's and Begg's tests. Fourteen studies comparing DEB-TACE or {sup 90}Y-radioembolization with cTACE were included. Analysis revealed a 1-year overall survival benefit for DEB-TACE over {sup 90}Y-radioembolization (79 % vs. 54.8 %; OR: 0.57; 95 %CI: 0.355-0.915; p = 0.02; I-squared: 0 %; p > 0.5), but not for the 2-year (61 % vs. 34 %; OR: 0.65; 95%CI: 0.294-1.437; p = 0.29) and 3-year survival (56.4 % vs. 20.9 %; OR: 0.713; 95 % CI: 0.21-2.548; p = 0.62). There was significant heterogeneity in the 2- and 3-year survival analyses. The pooled median overall survival was longer for DEB-TACE (22.6 vs. 14.7 months). There was no significant difference in tumour response rate. DEB-TACE and {sup 90}Y-radioembolization are efficacious treatments for patients suffering from HCC; DEB-TACE demonstrated survival benefit at 1-year compared to {sup 90}Y-radioembolization but direct comparison is warranted for further evaluation. (orig.)

  12. Coupling sequential injection on-line preconcentration by means of a renewable microcolumn with ion-exchange beads with detection by electrothermal atomic absorption spectrometry. Comparing the performance of eluting the loaded beads with transporting them directly into the graphite tube

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2001-01-01

    The design of a flow injection/sequential injection (FIA/SIA) on-line preconcentration system incorporating a renewable microcolumn with ion-exchange beads and interfaced with an electrothermal atomic absorption spectrometry (ETAAS) detector is described, and its practical applicability.......4% for the procedure in which the loaded beads are transported directly to the graphite furnace for pyrolysis and atomization, and even improved in comparison to the traditional unidirectional and bidirectional repetitive elution procedures which under comparable conditions yield R.S.D.-values of 5.8 and 4...

  13. Safeguards Analytical Laboratory evaluation program. Part 1. Resin bead mass spectrometry. Part 2. Results of a resin bead field experiment-Tastex-J

    International Nuclear Information System (INIS)

    Walker, R.L.; Smith, D.H.; Carter, J.A.; Musick, W.R.; Donohue, D.L.; Deron, S.; Asakura, Y.; Kagami, K.; Irinouchi, S.; Masui, J.

    1981-01-01

    The first part of this report covers background of resin bead spectrometry and the new batch resin bead method. In the original technique, about ten anion resin beads in the nitrate form were exposed to the diluted sample solution. The solution was adjusted to be a 8 M HNO 3 and to have about 1 μg U per bead. Up to 48 hours of static contact between beads and solution was required for adsorption of 1 to 3 ng Pu and U per bead to be achieved. Under these conditions, contamination was a problem at reprocessing facilities. The new batch techniques reduces the risk of contamination by handling one hundred times more U in the final diluted sample which is exposed to a proportionately larger number of beads. Moreover, it only requires ten minutes adsorption time to provide about 1000 purified samples for mass spectrometry. The amounts of Pu and U adsorbed versus time were determined and results are tabulated. The second part of this report briefly summarizes results of resin bead field tests completed at the Power Reactor and Nuclear Fuel Development Corporation (PNC) reprocessing plant in Tokai-mura, Japan. Both methods, the original small-sample resin bead and the batch technique, were investigated on spent fuel solutions. Beads were prepared at PNC and distributed to IAEA and ORNL along with dried residues for conventional mass spectrometric analysis at IAEA. Parallel measurements were made at PNC using their normal measuring routines. The U and Pu measurements of all resin and those of PNC are in excellent agreement for the batch method. Discrepancies were noted in the U measurements by the original method

  14. Drug-Eluting Beads Loaded With Doxorubicin (DEBDOX) Chemoembolisation Before Liver Transplantation for Hepatocellular Carcinoma: An Imaging/Histologic Correlation Study

    Energy Technology Data Exchange (ETDEWEB)

    Pauwels, Xavier, E-mail: xpauwels@hotmail.com; Azahaf, Mustapha, E-mail: mustapha.azahaf@chru-lille.fr [CHRU Lille, Hôpital Claude Huriez, Department of Digestive Diagnostic and Interventional Radiology (France); Lassailly, Guillaume, E-mail: guillaume.lassailly@chru-lille.fr [CHRU Lille, Hôpital Claude Huriez, Department of Digestive Diseases and Nutrition (France); Sergent, Géraldine, E-mail: geraldine.sergent@chru-lille.fr [CHRU Lille, Hôpital Claude Huriez, Department of Digestive Diagnostic and Interventional Radiology (France); Buob, David, E-mail: david.buob@chru-lille.fr [CHRU Lille, Department of Pathology (France); Truant, Stéphanie, E-mail: stephanie.truant@chru-lille.fr; Boleslawski, Emmanuel, E-mail: emmanuel.boleslawski@gmail.com [CHRU Lille, Hôpital Claude Huriez, Department of Digestive Surgery and Transplantation (France); Louvet, Alexandre, E-mail: alexandre.louvet@chru-lille.fr [CHRU Lille, Hôpital Claude Huriez, Department of Digestive Diseases and Nutrition (France); Gnemmi, Vivianne, E-mail: viviane.gnemmi@chru-lille.fr [CHRU Lille, Department of Pathology (France); Canva, Valérie, E-mail: valerie.canva@chru-lille.fr; Mathurin, Philippe, E-mail: philippe.mathurin@chru-lille.fr [CHRU Lille, Hôpital Claude Huriez, Department of Digestive Diseases and Nutrition (France); Pruvot, François-René, E-mail: francois-rene.pruvot@chru-lille.fr [CHRU Lille, Hôpital Claude Huriez, Department of Digestive Surgery and Transplantation (France); Leteurtre, Emmanuelle, E-mail: emmanuelle.leteurtre@chru-lille.fr [CHRU Lille, Department of Pathology (France); and others

    2015-06-15

    Purpose Most transplant centers use chemoembolisation as locoregional bridge therapy for hepatocellular carcinoma (HCC) before liver transplantation (LT). Chemoembolisation using beads loaded with doxorubicin (DEBDOX) is a promising technique that enables delivery of a large quantity of drugs against HCC. We sought to assess the imaging–histologic correlation after DEBDOX chemoembolisation.Materials and Methods All consecutive patients who had undergone DEBDOX chemoembolisation before receiving liver graft for HCC were included. Tumour response was evaluated according to Response Evaluation Criteria in Solid Tumours (RECIST) and modified RECIST (mRECIST) criteria. The result of final imaging made before LT was correlated with histological data to predict tumour necrosis.ResultsTwenty-eight patients underwent 43 DEBDOX procedures for 45 HCC. Therapy had a significant effect as shown by a decrease in the mean size of the largest nodule (p = 0.02) and the sum of viable part of tumour sizes according to mRECIST criteria (p < 0.001). An objective response using mRECIST criteria was significantly correlated with mean tumour necrosis ≥90 % (p = 0.03). A complete response using mRECIST criteria enabled accurate prediction of complete tumour necrosis (p = 0.01). Correlations using RECIST criteria were not significant.ConclusionOur data confirm the potential benefit of DEBDOX chemoembolisation as bridge therapy before LT, and they provide a rational basis for new studies focusing on recurrence-free survival after LT. Radiologic evaluation according to mRECIST criteria enables accurate prediction of tumour necrosis, whereas RECIST criteria do not.

  15. HIGH ASPECT RATIO ION EXCHANGE RESIN BED - HYDRAULIC RESULTS FOR SPERICAL RESIN BEADS

    International Nuclear Information System (INIS)

    Duignan, M; Charles Nash, C; Timothy Punch, T

    2007-01-01

    A principal role of the DOE Savannah River Site is to safely dispose of a large volume of liquid nuclear waste held in many storage tanks. An in-tank ion exchange unit is being considered for cesium removal to accelerate waste processing. This unit is planned to have a relatively high bed height to diameter ratio (10:1). Complicating the design is the need to cool the ion exchange media; therefore, the ion exchange column will have a central cooling core making the flow path annular. To separate cesium from waste the media being considered is made of resorcinol formaldehyde resin deposited on spherical plastic beads and is a substitute for a previously tested resin made of crystalline silicotitanate. This spherical media not only has an advantage of being mechanically robust, but, unlike its predecessor, it is also reusable, that is, loaded cesium can be removed through elution and regeneration. Resin regeneration leads to more efficient operation and less spent resin waste, but its hydraulic performance in the planned ion exchange column was unknown. Moreover, the recycling process of this spherical resorcinol formaldehyde causes its volume to significantly shrink and swell. To determine the spherical media's hydraulic demand a linearly scaled column was designed and tested. The waste simulant used was prototypic of the wastes' viscosity and density. This paper discusses the hydraulic performance of the media that will be used to assist in the design of a full-scale unit

  16. Differentiated analysis of an everolimus-eluting stent and a paclitaxel-eluting stent among higher risk subgroups for restenosis: results from the SPIRIT II trial.

    Science.gov (United States)

    Khattab, Ahmed A; Richardt, Gert; Verin, Vitali; Kelbaek, Henning; Macaya, Carlos; Berland, Jacques; Miquel-Hebert, Karine; Dorange, Cécile; Serruys, Patrick W

    2008-03-01

    Restenosis is higher among certain subpopulations when subjected to percutaneous coronary interventions even when using drug-eluting stents. The randomised SPIRIT II trial demonstrated the superiority of the XIENCE V Everolimus Eluting Coronary Stent System over the TAXUS Paclitaxel-Eluting Stent System in terms of in-stent late loss at six months among 300 patients treated for de novo native coronary artery lesions. In this post-hoc analysis of SPIRIT II we focused on six-month angiographic outcomes of diabetic patients (n=69), left anterior descending arteries (n=149), long lesions >20 mm (n=43), small vessels B2 and C lesions (n=233). In-stent late loss was consistently less among all subgroups when treated by everolimus-eluting stents compared to paclitaxel-eluting stents: diabetics 0.15+/-0.26 mm versus 0.39+/-0.34 mm, p=0.006; LAD 0.12+/-0.23 mm versus 0.44+/-0.37 mm, pB2/C lesions 0.12+/-0.31 mm versus 0.36+/-0.36 mm, pSPIRIT II trial population.

  17. Endeavour zotarolimus-eluting stent reduces stent thrombosis and improves clinical outcomes compared with cypher sirolimus-eluting stent : 4-year results of the PROTECT randomized trial

    NARCIS (Netherlands)

    Wijns, William; Steg, Ph. Gabriel; Mauri, Laura; Kurowski, Volkhard; Parikh, Keyur; Gao, Runlin; Bode, Christoph; Greenwood, John P.; Lipsic, Erik; Alamgir, Farqad; Rademaker-Havinga, Tessa; Boersma, Eric; Radke, Peter; van Leeuwen, Frank; Camenzind, Edoardo

    2014-01-01

    Aims To compare the long-term clinical safety between two drug-eluting stents with different healing characteristics in the Patient Related Outcomes with Endeavour (E-ZES) vs. Cypher (C-SES) Stenting Trial (PROTECT). At 3 years, there was no difference in the primary outcome of definite or probable

  18. Influence of Immobilized Biomolecules on Magnetic Bead Plug Formation and Retention in Capillary Electrophoresis

    Science.gov (United States)

    Henken, Rachel L.; Chantiwas, Rattikan; Gilman, S. Douglass

    2012-01-01

    Significant changes in the formation and retention of magnetic bead plugs in a capillary during electrophoresis were studied, and it was demonstrated that these effects were due to the type of biological molecule immobilized on the surface of these beads. Three biological molecules, an antibody, an oligonucleotide and alkaline phosphatase, were attached to otherwise identical streptavidin-coated magnetic beads through biotin-avidin binding in order to isolate differences in bead immobilization in a magnetic field resulting from the type of biological molecule immobilized on the bead surface. Alkaline phosphatase also was attached to the magnetic beads using epoxy groups on the bead surfaces (instead of avidin-biotin binding) to study the impact of immobilization chemistry. The formation and retention of magnetic bead plugs were studied quantitatively using light scattering detection of magnetic particles eluting from the bead plugs and qualitatively using microscopy. Both the type of biomolecule immobilized on the magnetic bead surface and the chemistry used to link the biomolecule to the magnetic bead impacted the formation and retention of the bead plugs. PMID:22437880

  19. Intra-arterial therapy of neuroendocrine tumour liver metastases: comparing conventional TACE, drug-eluting beads TACE and yttrium-90 radioembolisation as treatment options using a propensity score analysis model

    Energy Technology Data Exchange (ETDEWEB)

    Minh, Duc Do; Gorodetski, Boris; Smolka, Susanne; Savic, Lynn Jeanette; Wainstejn, David [Charite Universitaetsmedizin, Campus Virchow Klinikum, Department of Diagnostic and Interventional Radiology, Berlin (Germany); Yale University School of Medicine, Department of Radiology and Biomedical Imaging, New Haven, CT (United States); Chapiro, Julius; Schlachter, Todd [Yale University School of Medicine, Department of Radiology and Biomedical Imaging, New Haven, CT (United States); Huang, Qiang [Yale University School of Medicine, Department of Radiology and Biomedical Imaging, New Haven, CT (United States); Capital Medical University, Department of Interventional Radiology, Beijing Chaoyang Hospital, Beijing (China); Liu, Cuihong [Yale University School of Medicine, Department of Radiology and Biomedical Imaging, New Haven, CT (United States); Shandong Provincial Hospital Affiliated to Shandong University, The Ultrasound Department, Jinan (China); Lin, MingDe [Yale University School of Medicine, Department of Radiology and Biomedical Imaging, New Haven, CT (United States); Philips Research North America, U/S Imaging and Interventions (UII), Cambridge, MA (United States); Gebauer, Bernhard [Charite Universitaetsmedizin, Campus Virchow Klinikum, Department of Diagnostic and Interventional Radiology, Berlin (Germany); Geschwind, Jean-Francois [Yale University School of Medicine, Department of Radiology and Biomedical Imaging, New Haven, CT (United States)

    2017-12-15

    To compare efficacy, survival outcome and prognostic factors of conventional transarterial chemoembolisation (cTACE), drug-eluting beads TACE (DEB-TACE) and yttrium-90 radioembolisation (Y90) for the treatment of liver metastases from gastroenteropancreatic (GEP) neuroendocrine tumours (NELM). This retrospective analysis included 192 patients (58.6 years mean age, 56% men) with NELM treated with cTACE (N = 122), DEB-TACE (N = 26) or Y90 (N = 44) between 2000 and 2014. Radiologic response to therapy was assessed according to Response Evaluation Criteria in Solid Tumours (RECIST) and World Health Organization (WHO) criteria using periprocedural MR imaging. Survival analysis included propensity score analysis (PSA), median overall survival (MOS), hepatic progression-free survival, Kaplan-Meier using log-rank test and the uni- and multivariate Cox proportional hazards model (MVA). MOS of the entire study population was 28.8 months. As for cTACE, DEB-TACE and Y90, MOS was 33.8 months, 21.7 months and 23.6 months, respectively. According to the MVA, cTACE demonstrated a significantly longer MOS as compared to DEB-TACE (p <.01) or Y90 (p =.02). The 5-year survival rate after initial cTACE, DEB-TACE and Y90 was 28.2%, 10.3% and 18.5%, respectively. Upon PSA, our study suggests significant survival benefits for patients treated with cTACE as compared to DEB-TACE and Y90. This data supports the therapeutic decision for cTACE as the primary intra-arterial therapy option in patients with unresectable NELM until proven otherwise. (orig.)

  20. Clinical results with the Resolute zotarolimus-eluting stent in total coronary occlusions

    DEFF Research Database (Denmark)

    Kelbæk, Henning; Holmvang, Lene; Richardt, Gert

    2015-01-01

    Aims: We conducted a pooled post hoc analysis (RESOLUTE All Comers and RESOLUTE International) of patients who had the Resolute® zotarolimus-eluting stent (R-ZES) implanted in revascularised total occlusions (TO) compared with patients treated with R-ZES for non-occluded lesions. Methods and resu......Aims: We conducted a pooled post hoc analysis (RESOLUTE All Comers and RESOLUTE International) of patients who had the Resolute® zotarolimus-eluting stent (R-ZES) implanted in revascularised total occlusions (TO) compared with patients treated with R-ZES for non-occluded lesions. Methods...... lesion revascularisation) and Academic Research Consortium definite or probable stent thrombosis. The rate of TLF at two years was not significantly different among patients in the CTO (9.1%), TO (9.8%), and no occlusion (10.4%) groups (log-rank p=0.800); neither were the components of TLF. Definite...... or probable stent thrombosis occurred more frequently in the TO group (2.8% vs. 1.2% in the CTO and 1.1% in the group with no occlusion, p=0.027). There were 10 late and six very late stent thrombosis events. Conclusions: Apart from a higher rate of stent thrombosis in patients with TO, patients with totally...

  1. Role of diffusion-weighted magnetic resonance imaging in the evaluation of hepatocellular carcinoma response to transcatheter arterial chemoembolization using drug eluting beads; correlation with dynamic MRI

    Directory of Open Access Journals (Sweden)

    Mohamed I. Yousef

    2017-12-01

    Conclusion: DWI is useful highly sensitive technique in evaluation of HCC response to DEB TACE, yet it has low specificity related to high number of false positive results preventing using it solely. Also, DWIs is a reliable method in differentiation between active tumor residue/recurrence and benign perilesional enhancement.

  2. Randomized Comparison of Selective Internal Radiotherapy (SIRT) Versus Drug-Eluting Bead Transarterial Chemoembolization (DEB-TACE) for the Treatment of Hepatocellular Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Pitton, Michael B., E-mail: michael.pitton@unimedizin-mainz.de; Kloeckner, Roman [Johannes Gutenberg University Medical Center, Department of Diagnostic and Interventional Radiology (Germany); Ruckes, Christian [Johannes Gutenberg University Medical Center, IZKS (Germany); Wirth, Gesine M. [Johannes Gutenberg University Medical Center, Department of Diagnostic and Interventional Radiology (Germany); Eichhorn, Waltraud [Johannes Gutenberg University Medical Center, Department of Nuclear Medicine (Germany); Wörns, Marcus A.; Weinmann, Arndt [Johannes Gutenberg University Medical Center, Department of Internal Medicine (Germany); Schreckenberger, Mathias [Johannes Gutenberg University Medical Center, Department of Nuclear Medicine (Germany); Galle, Peter R. [Johannes Gutenberg University Medical Center, Department of Internal Medicine (Germany); Otto, Gerd [Johannes Gutenberg University Medical Center, Department of Transplantation Surgery (Germany); Dueber, Christoph [Johannes Gutenberg University Medical Center, Department of Diagnostic and Interventional Radiology (Germany)

    2015-04-15

    PurposeTo prospectively compare SIRT and DEB-TACE for treating hepatocellular carcinoma (HCC).MethodsFrom 04/2010–07/2012, 24 patients with histologically proven unresectable N0, M0 HCCs were randomized 1:1 to receive SIRT or DEB-TACE. SIRT could be repeated once in case of recurrence; while, TACE was repeated every 6 weeks until no viable tumor tissue was detected by MRI or contraindications prohibited further treatment. Patients were followed-up by MRI every 3 months; the final evaluation was 05/2013.ResultsBoth groups were comparable in demographics (SIRT: 8males/4females, mean age 72 ± 7 years; TACE: 10males/2females, mean age 71 ± 9 years), initial tumor load (1 patient ≥25 % in each group), and BCLC (Barcelona Clinic Liver Cancer) stage (SIRT: 12×B; TACE 1×A, 11×B). Median progression-free survival (PFS) was 180 days for SIRT versus 216 days for TACE patients (p = 0.6193) with a median TTP of 371 days versus 336 days, respectively (p = 0.5764). Median OS was 592 days for SIRT versus 788 days for TACE patients (p = 0.9271). Seven patients died in each group. Causes of death were liver failure (n = 4 SIRT group), tumor progression (n = 4 TACE group), cardiovascular events, and inconclusive (n = 1 in each group).ConclusionsNo significant differences were found in median PFS, OS, and TTP. The lower rate of tumor progression in the SIRT group was nullified by a greater incidence of liver failure. This pilot study is the first prospective randomized trial comparing SIRT and TACE for treating HCC, and results can be used for sample size calculations of future studies.

  3. Randomized Comparison of Selective Internal Radiotherapy (SIRT) Versus Drug-Eluting Bead Transarterial Chemoembolization (DEB-TACE) for the Treatment of Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Pitton, Michael B.; Kloeckner, Roman; Ruckes, Christian; Wirth, Gesine M.; Eichhorn, Waltraud; Wörns, Marcus A.; Weinmann, Arndt; Schreckenberger, Mathias; Galle, Peter R.; Otto, Gerd; Dueber, Christoph

    2015-01-01

    PurposeTo prospectively compare SIRT and DEB-TACE for treating hepatocellular carcinoma (HCC).MethodsFrom 04/2010–07/2012, 24 patients with histologically proven unresectable N0, M0 HCCs were randomized 1:1 to receive SIRT or DEB-TACE. SIRT could be repeated once in case of recurrence; while, TACE was repeated every 6 weeks until no viable tumor tissue was detected by MRI or contraindications prohibited further treatment. Patients were followed-up by MRI every 3 months; the final evaluation was 05/2013.ResultsBoth groups were comparable in demographics (SIRT: 8males/4females, mean age 72 ± 7 years; TACE: 10males/2females, mean age 71 ± 9 years), initial tumor load (1 patient ≥25 % in each group), and BCLC (Barcelona Clinic Liver Cancer) stage (SIRT: 12×B; TACE 1×A, 11×B). Median progression-free survival (PFS) was 180 days for SIRT versus 216 days for TACE patients (p = 0.6193) with a median TTP of 371 days versus 336 days, respectively (p = 0.5764). Median OS was 592 days for SIRT versus 788 days for TACE patients (p = 0.9271). Seven patients died in each group. Causes of death were liver failure (n = 4 SIRT group), tumor progression (n = 4 TACE group), cardiovascular events, and inconclusive (n = 1 in each group).ConclusionsNo significant differences were found in median PFS, OS, and TTP. The lower rate of tumor progression in the SIRT group was nullified by a greater incidence of liver failure. This pilot study is the first prospective randomized trial comparing SIRT and TACE for treating HCC, and results can be used for sample size calculations of future studies

  4. A novel magnet focusing plate for matrix-assisted laser desorption/ionization analysis of magnetic bead-bound analytes.

    Science.gov (United States)

    Gode, David; Volmer, Dietrich A

    2013-05-15

    Magnetic beads are often used for serum profiling of peptide and protein biomarkers. In these assays, the bead-bound analytes are eluted from the beads prior to mass spectrometric analysis. This study describes a novel matrix-assisted laser desorption/ionization (MALDI) technique for direct application and focusing of magnetic beads to MALDI plates by means of dedicated micro-magnets as sample spots. Custom-made MALDI plates with magnetic focusing spots were made using small nickel-coated neodymium micro-magnets integrated into a stainless steel plate in a 16 × 24 (384) pattern. For demonstrating the proof-of-concept, commercial C-18 magnetic beads were used for the extraction of a test compound (reserpine) from aqueous solution. Experiments were conducted to study focusing abilities, the required laser energies, the influence of a matrix compound, dispensing techniques, solvent choice and the amount of magnetic beads. Dispensing the magnetic beads onto the micro-magnet sample spots resulted in immediate and strong binding to the magnetic surface. Light microscope images illustrated the homogeneous distribution of beads across the surfaces of the magnets, when the entire sample volume containing the beads was pipetted onto the surface. Subsequent MALDI analysis of the bead-bound analyte demonstrated excellent and reproducible ionization yields. The surface-assisted laser desorption/ionization (SALDI) properties of the strongly light-absorbing γ-Fe2O3-based beads resulted in similar ionization efficiencies to those obtained from experiments with an additional MALDI matrix compound. This feasibility study successfully demonstrated the magnetic focusing abilities for magnetic bead-bound analytes on a novel MALDI plate containing small micro-magnets as sample spots. One of the key advantages of this integrated approach is that no elution steps from magnetic beads were required during analyses compared with conventional bead experiments. Copyright © 2013 John Wiley

  5. An Attempt to Shorten Loading Time of Epirubicin into DC Beads® Using Vibration and a Sieve

    International Nuclear Information System (INIS)

    Sonoda, Akinaga; Nitta, Norihisa; Yamamoto, Takefumi; Tomozawa, Yuki; Ohta, Shinichi; Watanabe, Shobu; Murata, Kiyoshi

    2017-01-01

    PurposeWe investigated the possibility of shortening the time required for loading epirubicin into calibrated polyvinyl alcohol-based hydrogel beads (DC Beads ® ) to be used for transarterial chemoembolization.MethodAfter separating the beads suspended in phosphate-buffered saline (PBS) solution by the use of a sieve (clearance 75 µm), epirubicin hydrochloride (EH) was loaded for 20, 30, or 60 s under vibration into DC beads. The EH loading rate into conventionally prepared (control) beads, i.e., beads loaded for 30 min without vibration, and vibration-loaded beads were calculated from the residual EH concentration in the bead-depleted EH solution. The amount of EH eluted from conventionally and vibration-loaded samples into a PBS solution (pH 7.0) was measured at 15 and 30 min and 1, 2, 6, 12, and 24 h. We also recorded the inhibitory effect of the PBS solution on the loading time. Using frozen sections, the EH load in the beads was evaluated visually under a fluorescence microscope.ResultsSpectrophotometry (495 nm) showed that the loading rate was 98.98 ± 0.34, 99.02 ± 0.32, and 99.50 ± 0.11 % with 20-, 30-, and 60-s vibration, respectively. The eluted rate was statistically similar between vibration- and statically loaded (control) beads. The PBS solution hampered EH loading into the beads. Visually, the distribution of EH in conventionally and vibration-loaded DC beads was similar.DiscussionThe use of vibration and the removal of PBS solution when epirubicin hydrochloride was loaded into DC beads dramatically shortened the loading time of epirubicin hydrochloride into DC beads.

  6. An Attempt to Shorten Loading Time of Epirubicin into DC Beads{sup ®} Using Vibration and a Sieve

    Energy Technology Data Exchange (ETDEWEB)

    Sonoda, Akinaga, E-mail: akinagasonoda@yahoo.co.jp; Nitta, Norihisa [Shiga University of Medical Science, Department of Radiology (Japan); Yamamoto, Takefumi [Shiga University of Medical Science, Central Research Laboratory (Japan); Tomozawa, Yuki; Ohta, Shinichi; Watanabe, Shobu; Murata, Kiyoshi [Shiga University of Medical Science, Department of Radiology (Japan)

    2017-04-15

    PurposeWe investigated the possibility of shortening the time required for loading epirubicin into calibrated polyvinyl alcohol-based hydrogel beads (DC Beads{sup ®}) to be used for transarterial chemoembolization.MethodAfter separating the beads suspended in phosphate-buffered saline (PBS) solution by the use of a sieve (clearance 75 µm), epirubicin hydrochloride (EH) was loaded for 20, 30, or 60 s under vibration into DC beads. The EH loading rate into conventionally prepared (control) beads, i.e., beads loaded for 30 min without vibration, and vibration-loaded beads were calculated from the residual EH concentration in the bead-depleted EH solution. The amount of EH eluted from conventionally and vibration-loaded samples into a PBS solution (pH 7.0) was measured at 15 and 30 min and 1, 2, 6, 12, and 24 h. We also recorded the inhibitory effect of the PBS solution on the loading time. Using frozen sections, the EH load in the beads was evaluated visually under a fluorescence microscope.ResultsSpectrophotometry (495 nm) showed that the loading rate was 98.98 ± 0.34, 99.02 ± 0.32, and 99.50 ± 0.11 % with 20-, 30-, and 60-s vibration, respectively. The eluted rate was statistically similar between vibration- and statically loaded (control) beads. The PBS solution hampered EH loading into the beads. Visually, the distribution of EH in conventionally and vibration-loaded DC beads was similar.DiscussionThe use of vibration and the removal of PBS solution when epirubicin hydrochloride was loaded into DC beads dramatically shortened the loading time of epirubicin hydrochloride into DC beads.

  7. Long-Term Results of Everolimus-Eluting Stents Versus Drug-Eluting Balloons in Patients With Bare-Metal In-Stent Restenosis: 3-Year Follow-Up of the RIBS V Clinical Trial.

    Science.gov (United States)

    Alfonso, Fernando; Pérez-Vizcayno, María José; García Del Blanco, Bruno; Otaegui, Imanol; Masotti, Mónica; Zueco, Javier; Veláquez, Maite; Sanchís, Juan; García-Touchard, Arturo; Lázaro-García, Rosa; Moreu, José; Bethencourt, Armando; Cuesta, Javier; Rivero, Fernando; Cárdenas, Alberto; Gonzalo, Nieves; Jiménez-Quevedo, Pilar; Fernández, Cristina

    2016-06-27

    The aim of this study was to compare the long-term efficacy of everolimus-eluting stents (EES) and drug-eluting balloons (DEB) in patients with bare-metal stent in-stent restenosis (ISR). The relative long-term clinical efficacy of current therapeutic modalities in patients with ISR remains unknown. The 3-year clinical follow-up (pre-specified endpoint) of patients included in the RIBS V (Restenosis Intra-Stent of Bare-Metal Stents: Drug-Eluting Balloon vs Everolimus-Eluting Stent Implantation) randomized clinical trial was analyzed. All patients were followed yearly using a pre-defined structured questionnaire. A total of 189 patients with bare-metal stent ISR were allocated to either EES (n = 94) or DEB (n = 95). Clinical follow-up at 1, 2, and 3 years was obtained in all patients (100%). Compared with patients treated with DEB, those treated with EES obtained better angiographic results, including larger minimal luminal diameter at follow-up (primary study endpoint; 2.36 ± 0.6 mm vs. 2.01 ± 0.6 mm; p 1 year) target vessel (3 [3.2%] vs. 3 [3.2%]; p = 0.95) and target lesion (1 [1%] vs. 2 [2.1%]; p = 0.54) revascularization was low and similar in the 2 arms. Rates of definite or probable stent thrombosis (1% vs. 0%) were also similar in the 2 arms. The 3-year clinical follow-up of the RIBS V clinical trial confirms the sustained safety and efficacy of EES and DEB in patients treated for bare-metal stent ISR. In this setting, EES reduce the need for target lesion revascularization at very long-term follow-up. (RIBS V [Restenosis Intra-Stent of Bare Metal Stents: Paclitaxel-Eluting Balloon vs Everolimus-Eluting Stent] [RIBS V]; NCT01239953). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  8. Six-Month Clinical and Angiographic Results of Paclitaxel Eluting Simpax Stent

    Directory of Open Access Journals (Sweden)

    Mehmet Muhsin Türkmen

    2012-08-01

    Full Text Available Introduction: We aimed to evaluate the safety and efficacy of the simpax stent in the treatmentof different patient groups.Patients and Methods: Forty-five patients were treated with the simpax stent. Of these patients,23 patients gave consent for six months of follow-up by quantitative coronary angiography (QSAand six patients were evaluated by exercise electrocardiographic test. Only the patients havinglesions with stenosis > 50% of diameter and lengths > 16 mm with reference diameters < 2.75mm were included.Results: The device success rate was 100% and procedure success rate was 97.7%. The meanstent length was 24.6 ± 7.3 mm and stent size was 2.54 ± 0.24 mm. The overall six months incidenceof major adverse cardiac events (MACE was 8.8%. MACE was consisted of two casesof non-Q wave myocardial infarction and two cases of repeated revascularization of the targetlesion. MACE rate was higher in chronic total occlusion (CTO group than non-CTO group (respectively33.3% and 5.1. Also when compared to stent size, MACE rate was 25% in < 2.5 mm,0% ≥ 2.5 mm. The QSA results at six months showed in-stent late lumen loss witha diameter of0.25 ± 0.15 mm in 17 patients.Conclusion: The six month results in this study demonsrated excellent procedural and devicesuccess. Simpax stent was associated with a low in-stent late lumen loss. Also this study showedsimpax stent was a safe and effective device in non-CTO group with stent size ≥ 2.5 mm.

  9. A randomised comparison of novolimus-eluting and zotarolimus-eluting coronary stents: 9-Month follow-up results of the EXCELLA II study

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); S.A. Garg (Scot); A.C. Abizaid (Alexandre); J.A. Ormiston (John); S.W. Windecker (Stephan); S. Verheye (Stefan); C. Dubois (Christophe); J. Stewart (J.); K. Hauptmann (Karl); J. Schofer (Joachim); K. Stangl (Karl); B. Witzenbichler (Bernhard); M. Wiemer (Marcus); E. Barbato (Emanuele); T. de Vries (Ton); A.-M. den Drijver (Anne-Marie); H. Otake (Hiromasa); L. Meredith (Lynn); S. Toyloy (Sara); P.J. Fitzgerald (Peter)

    2010-01-01

    textabstractAims: Novolimus, a macrocyclic lactone with anti-proliferative properties, has a similar efficacy to currently available agents; however it requires a lower dose, and less polymer, and is therefore conceivably safer. Methods and results: The EXCELLA II study was a prospective,

  10. Single-pass continuous-flow leach test of PNL 76-68 glass: some selected Bead Leach I results

    International Nuclear Information System (INIS)

    Coles, D.G.

    1981-01-01

    A single-pass continuous-flow leach test of PNL 76-68 glass beads (7 mm dia) was concluded after 420 days of uninterrupted operation. Variables included in the experimental matrix were flow-rate, leachant composition, and temperature. Analysis was conducted on all leachate samples for 237 Np and 239 Pu as well as a number of nonradioactive elements. Results indicated that flow-rate and leachant systematically affected the leach rate, but only slightly. Temperature effects were significant. Plutonium leach rate was lower at higher temperature suggesting that Pu sorption onto the beads was enhanced at the higher temperature. The range of leach rates for all analyzed elements (except Pu), at both temperature, at all three flow rates, and with all three leachant compositions varied only three orders of magnitude. The range of variables used in this experiment covered those expected in many proposed repository environments. The preliminary interpretation of the results also indicated that matrix dissolution may be the dominant leaching mechanism, at least for Np in bicarbonate leachant. Regardless of the leaching mechanism the importance of this study is that it bounds the effects of repository environments when the ground water is oxidizing and when it doesn't reach the waste form until the waste has cooled to ambient rock temperature

  11. Single-pass continuous-flow leach test of PNL 76-68 glass: some selected Bead Leach I results

    International Nuclear Information System (INIS)

    Coles, D.G.

    1981-01-01

    A single-pass continuous-flow leach test of PNL 76-68 glass beads (7 mm dia) was concluded after 420 days of uninterrupted operation. Variables included in the experimental matrix were flow-rate, leachant composition, and temperature. Analysis was conducted on all leachate samples for 237 Np and 239 Pu as well as a number of nonradioactive elements. Results indicated that flow-rate and leachant systematically affected the leach rate, but only slightly. Temperature effects were significant. Plutonium leach rate was lower at higher temperature suggesting that Pu sorption onto the beads was enhanced at the higher temperature. The range of leach rates for all analyzed elements (except Pu), at both temperatures, at all three flow rates, and with all three leachant compositions varied over only three orders of magnitude. The range of variables used in this experiment covered those expected in many proposed repository environments. The preliminary interpretation of the results aPPh 3 also reacted with Mn 2 (CO) 10 and Cp 2 Mo 2 (CO) 6 to give a variety of products at room temperature. A radical mechanism was suggested

  12. Comparison of everolimus- and paclitaxel-eluting stents in patients with acute and stable coronary syndromes: pooled results from the SPIRIT (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) Trials.

    Science.gov (United States)

    Planer, David; Smits, Pieter C; Kereiakes, Dean J; Kedhi, Elvin; Fahy, Martin; Xu, Ke; Serruys, Patrick W; Stone, Gregg W

    2011-10-01

    This study sought to compare the clinical outcomes of everolimus-eluting stents (EES) versus paclitaxel-eluting stents (PES) in patients with acute coronary syndromes (ACS) and stable coronary artery disease (CAD). Although randomized trials have shown superiority of EES to PES, the safety and efficacy of EES in ACS is unknown. We performed a patient-level pooled analysis from the prospective, randomized SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) II, III, IV, and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) trials in which 2,381 patients with ACS and 4,404 patients with stable CAD were randomized to EES or to PES. Kaplan-Meier estimates of death, myocardial infarction (MI), ischemia-driven target lesion revascularization, and stent thrombosis were assessed at 2 years and stratified by clinical presentation (ACS vs. stable CAD). At 2 years, patients with ACS compared with stable CAD had higher rates of death (3.2% vs. 2.4%, hazard ratio [HR]: 1.37 [95% confidence interval (CI): 1.02 to 1.85], p = 0.04) and MI (4.9% vs. 3.4%, HR: 1.45 [95% CI: 1.14 to 1.85], p = 0.02). In patients with ACS, EES versus PES reduced the rate of death or MI (6.6% vs. 9.3%, HR: 0.70 [95% CI: 0.52 to 0.94], p = 0.02), stent thrombosis (0.7% vs. 2.9%, HR: 0.25 [95% CI: 0.12 to 0.52], p = 0.0002), and ischemia-driven target lesion revascularization (4.7% vs. 6.2%, HR: 0.69 [95% CI: 0.48 to 0.99], p = 0.04). In patients with stable CAD, EES reduced the rate of death or MI (4.5% vs. 7.1%, HR: 0.62 [95% CI: 0.48 to 0.80], p = 0.0002), stent thrombosis (0.7% vs. 1.8%, HR: 0.34 [95% CI: 0.19 to 0.62], p = 0.0002), and ischemia-driven target lesion revascularization (3.9% vs. 6.9%, HR: 0.55 [95% CI: 0.42 to 0.73], p SPIRIT II]; NCT00180310; SPIRIT III: A Clinical Evaluation of the Investigational Device XIENCE V Everolimus Eluting Coronary Stent System [EECSS] in the

  13. Glass bead cultivation of fungi

    DEFF Research Database (Denmark)

    Droce, Aida; Sørensen, Jens Laurids; Giese, H.

    2013-01-01

    Production of bioactive compounds and enzymes from filamentous fungi is highly dependent on cultivation conditions. Here we present an easy way to cultivate filamentous fungi on glass beads that allow complete control of nutrient supply. Secondary metabolite production in Fusarium graminearum...... and Fusarium solani cultivated on agar plates, in shaking liquid culture or on glass beads was compared. Agar plate culture and glass bead cultivation yielded comparable results while liquid culture had lower production of secondary metabolites. RNA extraction from glass beads and liquid cultures was easier...... to specific nutrient factors. •Fungal growth on glass beads eases and improves fungal RNA extraction....

  14. Cierny-Mader Type III chronic osteomyelitis: the results of patients treated with debridement, irrigation, vancomycin beads and systemic antibiotics

    Science.gov (United States)

    Karaduman, Mert

    2007-01-01

    Cierny-Mader (C-M) Type III osteomyelitis is defined as a localised lesion with both medullary and cortical involvement that is stable mechanically after debridement. The treatment of C-M Type III osteomyelitisis is difficult and requires a precise protocol to achieve a disease-free long-term follow-up. We report here the results of our study on 26 patients (19 men and 7 women; average age: 34.7 years) with C-M Type III osteomylelitis who were treated with radical debridement, irrigation, vancomycin-impregnated custom-made beads and culture-specific systemic antibiotics. Those patients with metaphyseal involvement were treated with deroofing of the cortex and debridement by means of a “trough” (16 patients); those with diaphyseal involvement were treated with both intramedullary reaming and debridement from a trough (ten patients). Antibiotic cement rods were used as an additional therapy in five patients with diaphyseal involvement. Recurrence developed in three patients and was attributed to inadequate debridement; all three patients were treated again in the same manner with success. The mean follow-up is currently 3.6 years (range: 2–6 years). All of the patients have normal clinical, radiographic and laboratory parameters, and all are ambulatory and have returned to their pretreatment level of activity or better. We conclude that C-M Type III chronic osteomyelitis can be safely treated with this protocol. PMID:17375299

  15. Five-year clinical and functional multislice computed tomography angiographic results after coronary implantation of the fully resorbable polymeric everolimus-eluting scaffold in patients with de novo coronary artery disease

    DEFF Research Database (Denmark)

    Onuma, Yoshinobu; Dudek, Dariusz; Thuesen, Leif

    2013-01-01

    This study sought to demonstrate the 5-year clinical and functional multislice computed tomography angiographic results after implantation of the fully resorbable everolimus-eluting scaffold (Absorb BVS, Abbott Vascular, Santa Clara, California).......This study sought to demonstrate the 5-year clinical and functional multislice computed tomography angiographic results after implantation of the fully resorbable everolimus-eluting scaffold (Absorb BVS, Abbott Vascular, Santa Clara, California)....

  16. Favorable Outcomes after Implantation of Biodegradable Polymer Coated Sirolimus-Eluting Stents in Diabetic Population: Results from INDOLIMUS-G Diabetic Registry

    Directory of Open Access Journals (Sweden)

    Anurag Polavarapu

    2015-01-01

    Full Text Available Objective. The main aim is to evaluate safety, efficacy, and clinical performance of the Indolimus (Sahajanand Medical Technologies Pvt. Ltd., Surat, India sirolimus-eluting stent in high-risk diabetic population with complex lesions. Methods. It was a multicentre, retrospective, non-randomized, single-arm study, which enrolled 372 diabetic patients treated with Indolimus. The primary endpoint of the study was major adverse cardiac events (MACE, which is a composite of cardiac death, target lesion revascularization (TLR, target vessel revascularization (TVR, myocardial infarction (MI, and stent thrombosis (ST. The clinical follow-ups were scheduled at 30 days, 6 months, and 9 months. Results. The mean age of the enrolled patients was 53.4 ± 10.2 years. A total of 437 lesions were intervened successfully with 483 stents (1.1 ± 0.3 per lesion. There were 256 (68.8% male patients. Hypertension and totally occluded lesions were found in 202 (54.3% and 45 (10.3% patients, respectively. The incidence of MACE at 30 days, 6 months and 9 months was 0 (0%, 6 (1.6%, and 8 (2.2%, respectively. The event-free survival at 9-month follow-up by Kaplan Meier method was found to be 97.8%. Conclusion. The use of biodegradable polymer coated sirolimus-eluting stent is associated with favorable outcomes. The results demonstrated in our study depict its safety and efficacy in diabetic population.

  17. Disposal of bead ion exchange resin wastes

    International Nuclear Information System (INIS)

    Gay, R.L.; Granthan, L.F.

    1985-01-01

    Bead ion exchange resin wastes are disposed of by a process which involves spray-drying a bead ion exchange resin waste in order to remove substantially all of the water present in such waste, including the water on the surface of the ion exchange resin beads and the water inside the ion exchange resin beads. The resulting dried ion exchange resin beads can then be solidified in a suitable solid matrix-forming material, such as a polymer, which solidifies to contain the dried ion exchange resin beads in a solid monolith suitable for disposal by burial or other conventional means

  18. Randomized Comparison of Ridaforolimus- and Zotarolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease: Primary Results From the BIONICS Trial (BioNIR Ridaforolimus-Eluting Coronary Stent System in Coronary Stenosis).

    Science.gov (United States)

    Kandzari, David E; Smits, Pieter C; Love, Michael P; Ben-Yehuda, Ori; Banai, Shmuel; Robinson, Simon D; Jonas, Michael; Kornowski, Ran; Bagur, Rodrigo; Iniguez, Andres; Danenberg, Haim; Feldman, Robert; Jauhar, Rajiv; Chandna, Harish; Parikh, Manish; Perlman, Gidon Y; Balcells, Mercedes; Markham, Peter; Ozan, Melek Ozgu; Genereux, Philippe; Edelman, Elazer R; Leon, Martin B; Stone, Gregg W

    2017-10-03

    The safety and efficacy of a novel cobalt alloy-based coronary stent with a durable elastomeric polymer eluting the antiproliferative agent ridaforolimus for treatment of patients with coronary artery disease is undetermined. A prospective, international 1:1 randomized trial was conducted to evaluate in a noninferiority design the relative safety and efficacy of ridaforolimus-eluting stents (RESs) and slow-release zotarolimus-eluting stents among 1919 patients undergoing percutaneous coronary intervention at 76 centers. Inclusion criteria allowed enrollment of patients with recent myocardial infarction, total occlusions, bifurcations lesions, and other complex conditions. Baseline clinical and angiographic characteristics were similar between the groups. Overall, mean age was 63.4 years, 32.5% had diabetes mellitus, and 39.7% presented with acute coronary syndromes. At 12 months, the primary end point of target lesion failure (composite of cardiac death, target vessel-related myocardial infarction, and target lesion revascularization) was 5.4% for both devices (upper bound of 1-sided 95% confidence interval 1.8%, P noninferiority =0.001). Definite/probable stent thrombosis rates were low in both groups (0.4% RES versus 0.6% zotarolimus-eluting stent, P =0.75); 13-month angiographic in-stent late lumen loss was 0.22±0.41 mm and 0.23±0.39 mm ( P noninferiority =0.004) for the RES and zotarolimus-eluting stent groups, respectively, and intravascular ultrasound percent neointimal hyperplasia was 8.10±5.81 and 8.85±7.77, respectively ( P noninferiority =0.01). In the present trial, which allowed broad inclusion criteria, the novel RESs met the prespecified criteria for noninferiority compared with zotarolimus-eluting stents for the primary end point of target lesion failure at 12 months and had similar measures of late lumen loss. These findings support the safety and efficacy of RESs in patients who are representative of clinical practice. URL: http

  19. A multicenter post-marketing evaluation of the Elixir DESolve® Novolimus-eluting bioresorbable coronary scaffold system: First results from the DESolve PMCF study.

    Science.gov (United States)

    Nef, Holger; Wiebe, Jens; Boeder, Niklas; Dörr, Oliver; Bauer, Timm; Hauptmann, Karl-Eugen; Latib, Azeem; Colombo, Antonio; Fischer, Dieter; Rudolph, Tanja; Foin, Nicolas; Richardt, Gert; Hamm, Christian

    2018-03-06

    To date, experience with bioresorbable scaffolds (BRS) that elute agents other than everolimus is limited. Thus, a post-marketing clinical follow-up study was conducted to evaluate the continued safety and effectiveness of the DESolve® NOVOLIMUS™ Eluting BRS as treatment for patients with stable coronary artery disease. The DESolve BRS combines a poly-l-lactide-based backbone with a biodegradable polylactide-based polymer and Novolimus, a macrocyclic lactone mTOR inhibitor. One hundred and two patients (mean age 62 years, 77.5% male) were enrolled at 10 European sites. Comparison of baseline and post-procedural angiographic assessment was performed, and a device-oriented composite endpoint (comprising cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization) and rate of scaffold thrombosis at 12 months were examined. The device was successfully delivered and deployed in 98.2% (107/109) of the lesions, with two failures to cross the lesion. A total of 100 patients (109 lesions) were treated with a DESolve BRS. Post-procedural angiographic assessment indicated an in-scaffold acute gain of 1.54 ± 0.44 mm, with a reduction in % diameter stenosis from 61.00 ± 11.29 to 12.69 ± 0.44. At 12 months, the device-oriented composite endpoint had occurred in 3.0% (3/100) of patients, with 1.0% (1/100) experiencing scaffold thrombosis and myocardial infarction and 3.0% (3/100) undergoing target lesion revascularization. There were no cardiac deaths. Results through 12 months indicate that the DESolve BRS is a safe and effective treatment for coronary lesions, though larger, long-term prospective studies are needed. © 2018 Wiley Periodicals, Inc.

  20. Elution behaviors of elements from the hair

    International Nuclear Information System (INIS)

    Akashi, Junko; Fukushima, Ichiro; Imahori, Akira

    1981-01-01

    The elution of the neutron activated elements out of hair soaked in some organic solvents and EDTA solution was studied. Soakage of the hair sample, which was washed with water and acetone in advance as IAEA's proposal, in ether and acetone for 30 minutes each resulted in no elution of Hg, Zn, Co and Se. Elution of Zn and Co from the powdered hair sample soaked in 0.1 M EDTA solution was rapid, while Zn did not elute out from the cut hair (2 -- 3 mm length) on the same condition. Hg, Se and Au were not eluted out by 0.1 M EDTA solution in the both case of cut hair and of powdered hair. Br was removed by 0.1 M EDTA solution from the cut hair and from the powdered hair with equal ease. (author)

  1. Risk of stent thrombosis among bare-metal stents, first-generation drug-eluting stents, and second-generation drug-eluting stents: results from a registry of 18,334 patients.

    Science.gov (United States)

    Tada, Tomohisa; Byrne, Robert A; Simunovic, Iva; King, Lamin A; Cassese, Salvatore; Joner, Michael; Fusaro, Massimiliano; Schneider, Simon; Schulz, Stefanie; Ibrahim, Tareq; Ott, Ilka; Massberg, Steffen; Laugwitz, Karl-Ludwig; Kastrati, Adnan

    2013-12-01

    This study sought to compare the risk of stent thrombosis among patients treated with bare-metal stents (BMS), first-generation drug-eluting stents (G1-DES), and second-generation drug-eluting stents (G2-DES) for a period of 3 years. In patients undergoing coronary stenting, there is a scarcity of long-term follow-up data on cohorts large enough to compare rates of stent thrombosis across the stent generations. A total of 18,334 patients undergoing successful coronary stent implantation from 1998 to 2011 at 2 centers in Munich, Germany, were included in this study. Patients were stratified into 3 groups according to treatment with BMS, G1-DES, and G2-DES. The cumulative incidence of definite stent thrombosis at 3 years was 1.5% with BMS, 2.2% with G1-DES, and 1.0% with G2-DES. On multivariate analysis, G1-DES compared with BMS showed a significantly higher risk of stent thrombosis (odds ratio [OR]: 2.05; 95% confidence interval [CI]: 1.47 to 2.86; p stent thrombosis compared with BMS (OR: 0.82; 95% CI: 0.56 to 1.19; p = 0.30). Beyond 1 year, the risk of stent thrombosis was significantly increased with G1-DES compared with BMS (OR: 4.72; 95% CI: 2.01 to 11.1; p stenting, compared with BMS, there was a significant excess risk of stent thrombosis at 3 years with G1-DES, driven by an increased risk of stent thrombosis events beyond 1 year. G2-DES were associated with a similar risk of stent thrombosis compared with BMS. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. Effect of algal density in bead, bead size and bead concentrations ...

    African Journals Online (AJOL)

    Effect of algal density in bead, bead size and bead concentrations on wastewater nutrient removal. ... African Journal of Biotechnology ... The bioreactor containing algal beads (4 mm diameter) with 1.5 x 106 cells bead-1 (cell stocking) at concentration of 10.66 beads ml-1 wastewater (1:3 bead: wastewater, v/v) achieved ...

  3. Risk and timing of clinical events according to diabetic status of patients treated with everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting stent: 2-year results from a propensity score matched comparison of ABSORB EXTEND and SPIRIT trials.

    Science.gov (United States)

    Campos, Carlos M; Caixeta, Adriano; Franken, Marcelo; Bartorelli, Antonio L; Whitbourn, Robert J; Wu, Chiung-Jen; Li Paul Kao, Hsien; Rosli, Mohd Ali; Carrie, Didier; De Bruyne, Bernard; Stone, Gregg W; Serruys, Patrick W; Abizaid, Alexandre

    2018-02-15

    to compare the occurrence of clinical events in diabetics treated with the Absorb bioresorbable vascular scaffold (Absorb BVS; Abbott Vascular, Santa Clara, CA) versus everolimus-eluting metal stents (EES; XIENCE V; Abbott Vascular, Santa Clara, CA) BACKGROUND: There are limited data dedicated to clinical outcomes of diabetic patients treated with bioresorbable scaffolds (BRS) at 2-year horizon. The present study included 812 patients in the ABSORB EXTEND study in which a total of 215 diabetic patients were treated with Absorb BVS. In addition, 882 diabetic patients treated with EES in pooled data from the SPIRIT clinical program (SPIRIT II, SPIRIT III and SPIRIT IV trials) were used for comparison by applying propensity score matching using 29 different variables. The primary endpoint was ischemia driven major adverse cardiac events (ID-MACE), including cardiac death, myocardial infarction (MI), and ischemia driven target lesion revascularization (ID-TLR). After 2 years, the ID-MACE rate was 6.5% in the Absorb BVS vs. 8.9% in the Xience group (P = 0.40). There was no difference for MACE components or definite/probable device thrombosis (HR: 1.43 [0.24,8.58]; P = 0.69). The occurrence of MACE was not different for both diabetic status (insulin- and non-insulin-requiring diabetes) in all time points up to the 2-year follow-up for the Absorb and Xience groups. In this largest ever patient-level pooled comparison on the treatment of diabetic patients with BRS out to two years, individuals with diabetes treated with the Absorb BVS had a similar rate of MACE as compared with diabetics treated with the Xience EES. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  4. Zilver PTX Post-Market Surveillance Study of Paclitaxel-Eluting Stents for Treating Femoropopliteal Artery Disease in Japan: 12-Month Results.

    Science.gov (United States)

    Yokoi, Hiroyoshi; Ohki, Takao; Kichikawa, Kimihiko; Nakamura, Masato; Komori, Kimihiro; Nanto, Shinsuke; O'Leary, Erin E; Lottes, Aaron E; Snyder, Scott A; Dake, Michael D

    2016-02-08

    This multicenter, prospective, post-market surveillance study in Japan evaluates the paclitaxel-coated Zilver PTX stent in real-world patients with complex lesions. The Zilver PTX stent is the first drug-eluting stent (DES) approved for the superficial femoral artery. Previously, results from a large randomized study and a complementary, large single-arm study supported the safety and effectiveness of the DES. There were no exclusion criteria, and consecutive patients with symptomatic peripheral artery disease (PAD) treated with the DES were enrolled in the study. Clinically driven target lesion revascularization (TLR) was defined as reintervention performed for ≥50% diameter stenosis after recurrent clinical symptoms of PAD. Clinical benefit was defined as freedom from persistent or worsening symptoms of ischemia. Patency was evaluated by duplex ultrasound where physicians considered this standard of care. In this study, 907 patients were enrolled at 95 institutions in Japan. There were numerous comorbidities including high incidences of diabetes (58.8%), chronic kidney disease (43.8%), and critical limb ischemia (21.5%). Lesions were also complex, with an average length of 14.7 cm, 41.6% total occlusions, and 18.6% in-stent restenosis. In total, 1,861 DES were placed in 1,075 lesions. Twelve-month follow-up was obtained for >95% of eligible patients. Freedom from TLR was 91.0%, and clinical benefit was 87.7% through 12 months. The 12-month primary patency rate was 86.4%. Despite more challenging lesions, results from the current study are similar to outcomes from the previous Zilver PTX studies, confirming the benefit of the Zilver PTX DES in a real-world patient population. (Zilver PTX Post-Market Study in Japan; NCT02254837). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  5. First-Generation Versus Second-Generation Drug-Eluting Stents in Coronary Chronic Total Occlusions: Two-Year Results of a Multicenter Registry.

    Directory of Open Access Journals (Sweden)

    Jong-Hwa Ahn

    Full Text Available Limited data are available regarding the long-term clinical outcomes of second-generation drug-eluting stents (DES versus first-generation DES in patients with coronary chronic total occlusion (CTO who undergo percutaneous coronary intervention (PCI. The aim of this study was to compare the clinical outcomes of second-generation DES with those of first-generation DES for the treatment of CTO.Between March 2003 and February 2012, 1,006 consecutive patients with CTO who underwent successful PCI using either first-generation DES (n = 557 or second-generation DES (n = 449 were enrolled in a multicenter, observational registry. Propensity-score matching was also performed. The primary outcome was cardiac death over a 2-year follow-up period. No significant differences were observed between the two groups regarding the incidence of cardiac death (first-generation DES versus second-generation DES; 2.5% vs 2.0%; hazard ratio [HR]: 0.86; 95% confidence interval [CI]: 0.37 to 1.98; p = 0.72 or major adverse cardiac events (MACE, 11.8% vs 11.4%; HR: 1.00; 95% CI: 0.67 to 1.50; p = 0.99. After propensity score matching, the incidences of cardiac death (HR: 0.86; 95% CI: 0.35 to 2.06; p = 0.86 and MACE (HR: 0.93; 95% CI: 0.63 to 1.37; p = 0.71 were still similar in both groups. Furthermore, no significant differences were observed between sirolimus-eluting, paclitaxel-eluting, zotarolimus-eluting, and everolimus-eluting stents regarding the incidence of cardiac death or MACE.This study shows that the efficacy of second-generation DES is comparable to that of first-generation DES for treatment of CTO over 2 years of follow-up.

  6. Microfluidic magnetic bead conveyor belt.

    Science.gov (United States)

    van Pelt, Stijn; Frijns, Arjan; den Toonder, Jaap

    2017-11-07

    Magnetic beads play an important role in the miniaturization of clinical diagnostics systems. In lab-on-chip platforms, beads can be made to link to a target species and can then be used for the manipulation and detection of this species. Current bead actuation systems utilize complex on-chip coil systems that offer low field strengths and little versatility. We demonstrate a novel system based on an external rotating magnetic field and on-chip soft-magnetic structures to focus the field locally. These structures were designed and optimized using finite element simulations in order to create a number of local flux density maxima. These maxima, to which the magnetic beads are attracted, move over the chip surface in a continuous way together with the rotation of the external field, resulting in a mechanism similar to that of a conveyor belt. A prototype was fabricated using PDMS molding techniques mixed with iron powder for the magnetic structures. In the subsequent experiments, a quadrupole electromagnet was used to create the rotating external field. We observed that beads formed agglomerates that rolled over the chip surface, just above the magnetic structures. Field rotation frequencies between 0.1-50 Hz were tested resulting in magnetic bead speeds of over 1 mm s -1 for the highest frequency. With this, we have shown that our novel concept works, combining a simple design and simple operation with a powerful and versatile method for bead actuation. This makes it a promising method for further research and utilization in lab-on-chip systems.

  7. Bead-size directed distribution of Pseudomonas aeruginosa results in distinct inflammatory response in a mouse model of chronic lung infection

    DEFF Research Database (Denmark)

    Christophersen, L J; Trøstrup, H; Damlund, Dina Silke Malling

    2012-01-01

    or in the peripheral respiratory zone. To study this we produced two distinct sizes of small alginate beads (SB) and large beads (LB) containing P. aeruginosa. In total, 175 BALB/c mice were infected with either SB or LB. At day 1 the quantitative bacteriology was higher in the SB group compared to the LB group (P

  8. Innovative Elution Processes for Recovering Uranium from Seawater

    International Nuclear Information System (INIS)

    Wai, Chien; Tian, Guoxin; Janke, Christopher

    2014-01-01

    Utilizing amidoxime-based polymer sorbents for extraction of uranium from seawater has attracted considerable interest in recent years. Uranium collected in the sorbent is recovered typically by elution with an acid. One drawback of acid elution is deterioration of the sorbent which is a significant factor that limits the economic competitiveness of the amidoxime-based sorbent systems for sequestering uranium from seawater. Developing innovative elution processes to improve efficiency and to minimize loss of sorbent capacity become essential in order to make this technology economically feasible for large-scale industrial applications. This project has evaluated several elution processes including acid elution, carbonate elution, and supercritical fluid elution for recovering uranium from amidoxime-based polymer sorbents. The elution efficiency, durability and sorbent regeneration for repeated uranium adsorption- desorption cycles in simulated seawater have been studied. Spectroscopic techniques are used to evaluate chemical nature of the sorbent before and after elution. A sodium carbonate-hydrogen peroxide elution process for effective removal of uranium from amidoxime-based sorbent is developed. The cause of this sodium carbonate and hydrogen peroxide synergistic leaching of uranium from amidoxime-based sorbent is attributed to the formation of an extremely stable uranyl peroxo-carbonato complex. The efficiency of uranium elution by the carbonate-hydrogen peroxide method is comparable to that of the hydrochloric acid elution but damage to the sorbent material is much less for the former. The carbonate- hydrogen peroxide elution also does not need any elaborate step to regenerate the sorbent as those required for hydrochloric acid leaching. Several CO2-soluble ligands have been tested for extraction of uranium from the sorbent in supercritical fluid carbon dioxide. A mixture of hexafluoroacetylacetone and tri-n-butylphosphate shows the best result but uranium

  9. Innovative Elution Processes for Recovering Uranium from Seawater

    Energy Technology Data Exchange (ETDEWEB)

    Wai, Chien [Univ. of Idaho, Moscow, ID (United States); Tian, Guoxin [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Janke, Christopher [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-05-29

    Utilizing amidoxime-based polymer sorbents for extraction of uranium from seawater has attracted considerable interest in recent years. Uranium collected in the sorbent is recovered typically by elution with an acid. One drawback of acid elution is deterioration of the sorbent which is a significant factor that limits the economic competitiveness of the amidoxime-based sorbent systems for sequestering uranium from seawater. Developing innovative elution processes to improve efficiency and to minimize loss of sorbent capacity become essential in order to make this technology economically feasible for large-scale industrial applications. This project has evaluated several elution processes including acid elution, carbonate elution, and supercritical fluid elution for recovering uranium from amidoxime-based polymer sorbents. The elution efficiency, durability and sorbent regeneration for repeated uranium adsorption- desorption cycles in simulated seawater have been studied. Spectroscopic techniques are used to evaluate chemical nature of the sorbent before and after elution. A sodium carbonate-hydrogen peroxide elution process for effective removal of uranium from amidoxime-based sorbent is developed. The cause of this sodium carbonate and hydrogen peroxide synergistic leaching of uranium from amidoxime-based sorbent is attributed to the formation of an extremely stable uranyl peroxo-carbonato complex. The efficiency of uranium elution by the carbonate-hydrogen peroxide method is comparable to that of the hydrochloric acid elution but damage to the sorbent material is much less for the former. The carbonate- hydrogen peroxide elution also does not need any elaborate step to regenerate the sorbent as those required for hydrochloric acid leaching. Several CO2-soluble ligands have been tested for extraction of uranium from the sorbent in supercritical fluid carbon dioxide. A mixture of hexafluoroacetylacetone and tri-n-butylphosphate shows the best result but uranium

  10. Quality-of-Life After Everolimus-Eluting Stents or Bypass Surgery for Left-Main Disease: Results From the EXCEL Trial.

    Science.gov (United States)

    Baron, Suzanne J; Chinnakondepalli, Khaja; Magnuson, Elizabeth A; Kandzari, David E; Puskas, John D; Ben-Yehuda, Ori; van Es, Gerrit-Anne; Taggart, David P; Morice, Marie-Claude; Lembo, Nicholas J; Brown, W Morris; Banning, Adrian; Simonton, Charles A; Kappetein, A Pieter; Sabik, Joseph F; Serruys, Patrick W; Stone, Gregg W; Cohen, David J

    2017-12-26

    The EXCEL (Evaluation of Xience Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) trial compared outcomes in patients with unprotected left main coronary artery disease (LMCAD) treated with coronary artery bypass graft (CABG) or percutaneous coronary intervention (PCI) using everolimus-eluting stents. Whereas rates of death, stroke, and myocardial infarction were similar at 36 months, event timing and repeat revascularization rates differed by treatment group. To understand the effects of revascularization strategy from the patient's perspective, a prospective quality of life (QoL) substudy was performed alongside the EXCEL trial. Between September 2010 and March 2014, 1,905 patients with LMCAD were randomized to undergo CABG or PCI, of whom 1,788 participated in the QoL substudy. QoL was assessed at baseline and 1, 12, and 36 months using the Seattle Angina Questionnaire, the 12-Item Short Form Health Survey, the Rose Dyspnea Scale, the Patient Health Questionnaire-8, and the EQ-5D. Differences between PCI and CABG were assessed using longitudinal random-effect growth curve models. Over 36 months, both PCI and CABG were associated with significant improvements in QoL compared with baseline. At 1 month, PCI was associated with better QoL than CABG. By 12 months though, these differences were largely attenuated, and by 36 months, there were no significant QoL differences between PCI and CABG. Among selected patients with LMCAD, both PCI and CABG result in similar QoL improvement through 36 months, although a greater early benefit is seen with PCI. Taken together with the 3-year clinical results of EXCEL, these findings suggest that PCI and CABG provide similar intermediate-term outcomes for patients with LMCAD. (Evaluation of Xience Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization [EXCEL]; NCT01205776). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier

  11. Bioresorbable Everolimus-Eluting Vascular Scaffold for Patients With Peripheral Artery Disease (ESPRIT I): 2-Year Clinical and Imaging Results.

    Science.gov (United States)

    Lammer, Johannes; Bosiers, Marc; Deloose, Koen; Schmidt, Andrej; Zeller, Thomas; Wolf, Florian; Lansink, Wouter; Sauguet, Antoine; Vermassen, Frank; Lauwers, Geert; Scheinert, Dierk; Popma, Jeffrey J; McGreevy, Robert; Rapoza, Richard; Schwartz, Lewis B; Jaff, Michael R

    2016-06-13

    This is the first-in-human study of a drug-eluting bioresorbable vascular scaffold (BVS) for treatment of peripheral artery disease (PAD) involving the external iliac artery (EIA) and superficial femoral artery (SFA). Drug-eluting BVS has shown promise in coronary arteries. The ESPRIT BVS system is a device-drug combination consisting of an everolimus-eluting poly-l-lactide scaffold. Safety and performance were evaluated in 35 subjects with symptomatic claudication. Lesions were located in the SFA (88.6%) and EIA (11.4%). Mean lesion length was 35.7 ± 16.0 mm. The study device was successfully deployed in 100% of cases, without recoil. Procedure-related minor complications were observed in 3 patients (groin hematoma, dissection). Within 2 years there was 1 unrelated death, but no patients in this cohort had an amputation. At 1 and 2 years, the binary restenosis rates were 12.1% and 16.1%, respectively, and target lesion revascularization was performed in 3 of 34 patients (8.8%) and 4 of 32 patients (11.8%), respectively. The ankle brachial index 0.75 ± 0.14 improved from pre-procedure to 0.96 ± 0.16 at 2 years' follow-up. At 2 years, 71.0% of the patients were Rutherford-Becker 0, and 93.5% achieved a maximum walking distance of 1,500 feet. The safety of the ESPRIT BVS was demonstrated with no procedure or device-related deaths or amputations within 2 years. The low occurrence of revascularizations was consistent with duplex-ultrasonography showing sustained patency at 2-years. (A Clinical Evaluation of the Abbott Vascular ESPRIT BVS [Bioresorbable Vascular Scaffold] System [ESPRIT I]; NCT01468974). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Investigation of the elution by seawater of caesium and strontium from loaded clinoptilolite

    International Nuclear Information System (INIS)

    Harder, B.R.; Mitchell, I.H.; Smyth, M.J.

    1985-07-01

    Simple investigations of the elution of caesium and strontium from loaded clinoptilolite are described. The clinoptilolite was loaded to levels expected in the British Nuclear Fuels plc SIXEP plant and contacted with seawater at approx. 15 C. (The elution time was measured until about 99% of the caesium and strontium had been eluted.) It was found that 99% of the caesium was eluted in 35 hours but the strontium (with more variable results) took at least 400 hours for 99% elution. (author)

  13. Prevalence and impact of high platelet reactivity in chronic kidney disease: results from the Assessment of Dual Antiplatelet Therapy with Drug-Eluting Stents registry.

    Science.gov (United States)

    Baber, Usman; Mehran, Roxana; Kirtane, Ajay J; Gurbel, Paul A; Christodoulidis, Georgios; Maehara, Akiko; Witzenbichler, Bernhard; Weisz, Giora; Rinaldi, Michael J; Metzger, D Christopher; Henry, Timothy D; Cox, David A; Duffy, Peter L; Mazzaferri, Ernest L; Xu, Ke; Parise, Helen; Brodie, Bruce R; Stuckey, Thomas D; Stone, Gregg W

    2015-06-01

    Chronic kidney disease (CKD) is associated with increased rates of adverse events after percutaneous coronary intervention. We sought to determine the impact of CKD on platelet reactivity in clopidogrel-treated patients and whether high platelet reactivity (HPR) confers a similar or differential risk for adverse events among patients with CKD and non-CKD. We performed a post hoc analysis of the Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents (ADAPT-DES) registry, which included 8582 patients undergoing percutaneous coronary intervention with drug-eluting stents and platelet function testing using the VerifyNow assay. We compared HPR and its impact on ischemic and bleeding events >2 years among patients with CKD and non-CKD. Patients with CKD (n=1367) were older, more often female, diabetic, and had lower ejection fraction compared with their non-CKD counterparts (n=7043). Although HPR prevalence increased with worsening renal function in unadjusted analyses, these associations were no longer present after adjustment. Major adverse cardiac event rates at 2 years among those without CKD or HPR, HPR alone, CKD alone, and both CKD and HPR were 9.0%, 11.2%, 13.3%, and 17.5%, respectively (Pimpact of HPR on ischemic and bleeding events is similar irrespective of CKD status. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00638794. © 2015 American Heart Association, Inc.

  14. A String of Beads

    Science.gov (United States)

    Mead, Kelly C.

    2006-01-01

    In this article, the author relates how she designed a math activity she called Beads to use in conjunction with their school's 100th day celebration. Beads has provided her kindergarten class with many opportunities to practice a variety of math skills - counting, patterning, sorting, comparing, making sets, predicting, identifying numerals,…

  15. A randomized study to compare bioactive titanium stents and everolimus-eluting stents in diabetic patients (TITANIC XV): 1-year results.

    Science.gov (United States)

    López-Mínguez, José R; Nogales-Asensio, Juan M; Doncel-Vecino, Luis J; Merchán-Herrera, Antonio; Pomar-Domingo, Francisco; Martínez-Romero, Pedro; Fernández-Díaz, José A; Valdesuso-Aguilar, Raúl; Moreu-Burgos, José; Díaz-Fernández, José

    2014-07-01

    Up to 25% of patients who undergo a percutaneous coronary intervention show some limitation in the use of drug-eluting stents. The aim of this study was to evaluate if titanium-nitride-oxide-coated stents could be a good alternative to everolimus-eluting stents in diabetic patients. A total of 173 diabetic patients with lesions at moderate risk of restenosis (exclusion criteria: diameter 28 mm in vessels < 3mm, chronic occlusion) were randomized to a titanium group (83 patients) or an everolimus group (90 patients). Baseline characteristics were well balanced; 28.3% of patients were insulin dependent. At 1 year, the incidence of major adverse cardiac events (death, nonfatal myocardial infarction, stroke, or repeat target vessel revascularization) was significantly higher in the titanium group than in the everolimus group (total, 14.5% vs 4.4%; P = .02; noninsulin-dependent subgroup, 9.7% vs 3.2%; P = .14; insulin-dependent subgroup, 28.6% vs 7.1%; P = .04). The incidence of death, nonfatal myocardial infarction, stroke, or any revascularization was 16.9% in the titanium group and 7.8% in the everolimus group (P = .06). Target lesion and vessel revascularizations occurred in 8.4% compared with 3.3% (P = .15) and in 13.3% compared with 3.3% (P = .01) in the titanium and everolimus groups, respectively. Angiographic follow-up at 9 months showed significantly less late lumen loss in the everolimus group (in-segment, 0.52 [standard deviation, 0.58) mm vs -0.05 [0.32] mm; in-stent, 0.76 [0.54] mm vs 0.13 [0.31] mm; P < .0001). The everolimus-eluting stent is superior to the titanium stent for clinical and angiographic end points in diabetic patients with lesions at moderate risk of restenosis. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  16. Five-year clinical and functional multislice computed tomography angiographic results after coronary implantation of the fully resorbable polymeric everolimus-eluting scaffold in patients with de novo coronary artery disease: the ABSORB cohort A trial.

    Science.gov (United States)

    Onuma, Yoshinobu; Dudek, Dariusz; Thuesen, Leif; Webster, Mark; Nieman, Koen; Garcia-Garcia, Hector M; Ormiston, John A; Serruys, Patrick W

    2013-10-01

    This study sought to demonstrate the 5-year clinical and functional multislice computed tomography angiographic results after implantation of the fully resorbable everolimus-eluting scaffold (Absorb BVS, Abbott Vascular, Santa Clara, California). Multimodality imaging of the first-in-humans trial using a ABSORB BVS scaffold demonstrated at 2 years the bioresorption of the device while preventing restenosis. However, the long-term safety and efficacy of this therapy remain to be documented. In the ABSORB cohort A trial (ABSORB Clinical Investigation, Cohort A [ABSORB A] Everolimus-Eluting Coronary Stent System Clinical Investigation), 30 patients with a single de novo coronary artery lesion were treated with the fully resorbable everolimus-eluting Absorb scaffold at 4 centers. As an optional investigation in 3 of the 4 centers, the patients underwent multislice computed tomography (MSCT) angiography at 18 months and 5 years. Acquired MSCT data were analyzed at an independent core laboratory (Cardialysis, Rotterdam, the Netherlands) for quantitative analysis of lumen dimensions and was further processed for calculation of fractional flow reserve (FFR) at another independent core laboratory (Heart Flow, Redwood City, California). Five-year clinical follow-up is available for 29 patients. One patient withdrew consent after 6 months, but the vital status of this patient remains available. At 46 days, 1 patient experienced a single episode of chest pain and underwent a target lesion revascularization with a slight troponin increase after the procedure. At 5 years, the ischemia-driven major adverse cardiac event rate of 3.4% remained unchanged. Clopidogrel was discontinued in all but 1 patient. Scaffold thrombosis was not observed in any patient. Two noncardiac deaths were reported, 1 caused by duodenal perforation and the other from Hodgkin's disease. At 5 years, 18 patients underwent MSCT angiography. All scaffolds were patent, with a median minimal lumen area of 3

  17. Long-term clinical and angiographic results of Sirolimus-Eluting Stent in Complex Coronary Chronic Total Occlusion Revascularization: the SECTOR registry.

    Science.gov (United States)

    Galassi, Alfredo R; Tomasello, Salvatore D; Costanzo, Luca; Campisano, Maria B; Barrano, Giombattista; Tamburino, Corrado

    2011-10-01

    Drug-eluting stents showed a better angiographic and clinical outcome in comparison with bare metal stent in chronic total occlusions (CTOs) percutaneous revascularization, however, great concerns still remain regarding the rate of restenosis and reocclusion in comparison with nonocclusive lesions. To evaluate angiographic and clinical outcomes after sirolimus-eluting stent (SES) implantation in the setting of a "real world" series of complex CTOs. From January 2006 to December 2008, 172 consecutive patients with 179 CTO lesions were enrolled into registry. Among these, successful recanalization was obtained in 144 lesions (80.4%) with exclusive SES implantation in 104 lesions. The 9-12 months angiographic follow-up was executed in 85.5% of lesions with evidence of angiographic binary restenosis in 16.8% of lesions. Total stent length and number of stent implanted were recognized as independent predictors of restenosis (odds ratio [OR] 4.7, 95% confidence interval [CI] 1.28-107.09, P = 0.02) and (OR 5.8, 95% CI 1.39-23.55, P = 0.01), respectively.The 2-year clinical follow-up showed rates of target lesion revascularization, non-Q wave myocardial infarction, and total major adverse cardiovascular events (MACEs) of 11.1%, 2%, and 13.1%, respectively. Cox proportional-hazard analysis showed diabetes as independent predictor of MACEs (hazard ratio [HR] 4.832; 95% CI, 0.730-0.861; P = 0.028). Data from this registry demonstrate the long-term efficacy and safety of SES implantation after complex CTOs recanalization. ©2011, Wiley Periodicals, Inc.

  18. Incidence of adverse cardiac events 5 years after polymer-free sirolimus eluting stent implantation: Results from the prospective Bad Berka Yukon Choice™ registry.

    Science.gov (United States)

    Ohlow, Marc-Alexander; von Korn, Hubertus; Gunkel, Oliver; Farah, Ahmed; Fuhrmann, Joerg T; Lauer, Bernward

    2014-12-01

    Drug-eluting stents (DES) constitute a major achievement in preventing re-stenosis, concerns remain regarding the increased inflammatory responses associated with the polymers used. This analysis focuses on outcomes in patients receiving the polymer-free sirolimus-eluting stent system YUKON-Choice (Yukon-DES, Translumina, Germany). From 01/2006-09/2008 all patients receiving Yukon-DES (≥2.5 mm diameter) were prospectively enrolled in our registry. The primary endpoint was long-term major adverse cardiac events (MACE). 701 patients were included in our registry. Mean age was 65.7 ± 10 years (73% male gender, 35.5% diabetes, and 32.2% acute coronary syndrome). 76% of the lesions were of Type B2/C. Lesion length was 24.6 ± 5.2 mm and mean stent diameter was 2.8 ± 0.4 mm. A total of 511 pts (72%) underwent 6-months angiographic follow-up, target vessel revascularization was noted in 23.5%. At 5 years clinical outcomes were: cardiac death 5.8%; myocardial infarction 3.4%; and TVR 24.6%. The incidence of MACE differed significantly between "on-label" and "off-label" indications (14.8% vs. 40.8% MACE; P 1 year) ST occurred in 0.29%. Our data suggests that the implantation of the sirolimus-coated polymer-free YUKON-DES is safe and feasible with a very low incidence of ST in this real world patient cohort with high percentage of diabetes and small vessels. © 2013 Wiley Periodicals, Inc.

  19. Three-bead steering microswimmers

    Science.gov (United States)

    Rizvi, Mohd Suhail; Farutin, Alexander; Misbah, Chaouqi

    2018-02-01

    The self-propelled microswimmers have recently attracted considerable attention as model systems for biological cell migration as well as artificial micromachines. A simple and well-studied microswimmer model consists of three identical spherical beads joined by two springs in a linear fashion with active oscillatory forces being applied on the beads to generate self-propulsion. We have extended this linear microswimmer configuration to a triangular geometry where the three beads are connected by three identical springs in an equilateral triangular manner. The active forces acting on each spring can lead to autonomous steering motion; i.e., allowing the swimmer to move along arbitrary paths. We explore the microswimmer dynamics analytically and pinpoint its rich character depending on the nature of the active forces. The microswimmers can translate along a straight trajectory, rotate at a fixed location, as well as perform a simultaneous translation and rotation resulting in complex curved trajectories. The sinusoidal active forces on the three springs of the microswimmer contain naturally four operating parameters which are more than required for the steering motion. We identify the minimal operating parameters which are essential for the motion of the microswimmer along any given arbitrary trajectory. Therefore, along with providing insights into the mechanics of the complex motion of the natural and artificial microswimmers, the triangular three-bead microswimmer can be utilized as a model for targeted drug delivery systems and autonomous underwater vehicles where intricate trajectories are involved.

  20. Fused Bead Analysis of Diogenite Meteorites

    Science.gov (United States)

    Mittlefehldt, D.W.; Beck, B.W.; McSween, H.Y.; Lee, C.T. A.

    2009-01-01

    Bulk rock chemistry is an essential dataset in meteoritics and planetary science [1]. A common method used to obtain the bulk chemistry of meteorites is ICP-MS. While the accuracy, precision and low detection limits of this process are advantageous [2], the sample size used for analysis (approx.70 mg) can be a problem in a field where small and finite samples are the norm. Fused bead analysis is another bulk rock analytical technique that has been used in meteoritics [3]. This technique involves forming a glass bead from 10 mg of sample and measuring its chemistry using a defocused beam on a microprobe. Though the ICP-MS has lower detection limits than the microprobe, the fused bead method destroys a much smaller sample of the meteorite. Fused bead analysis was initially designed for samples with near-eutectic compositions and low viscosities. Melts generated of this type homogenize at relatively low temperatures and produce primary melts near the sample s bulk composition [3]. The application of fused bead analysis to samples with noneutectic melt compositions has not been validated. The purpose of this study is to test if fused bead analysis can accurately determine the bulk rock chemistry of non-eutectic melt composition meteorites. To determine this, we conduct two examinations of the fused bead. First, we compare ICP-MS and fused bead results of the same samples using statistical analysis. Secondly, we inspect the beads for the presence of crystals and chemical heterogeneity. The presence of either of these would indicate incomplete melting and quenching of the bead.

  1. Gender difference on five-year outcomes of EXCEL biodegradable polymer-coated sirolimus-eluting stents implantation: results from the CREATE study.

    Science.gov (United States)

    Zhang, Lei; Qiao, Bing; Han, Ya-Ling; Li, Yi; Xu, Kai; Zhang, Quan-Yu; Yang, Li-Xia; Liu, Hui-Liang; Xu, Bo; Gao, Run-Lin

    2013-03-01

    The gender difference on long-term outcome in unselected patients after percutaneous coronary intervention (PCI) has not yet been fully investigated. This study aimed to evaluate the gender difference on five-year outcomes following EXCEL biodegradable polymer-coated sirolimus-eluting stenting in patients with coronary disease. A total of 2077 "all comers", consisting of 1528 (73.6%) men and 549 (26.4%) women, who were exclusively treated with EXCEL coronary stents were enrolled in the prospective CREATE study at 59 centers from four countries. After propensity score matching, the baseline characteristics of the two groups were well matched. Recommended antiplatelet regimen was clopidogrel and aspirin for six months followed by chronic aspirin therapy. The primary outcome that was the rate of major adverse cardiac events (MACE), defined as a composite of cardiac mortality, non-fatal myocardial infarction (MI) and target lesion revascularization (TLR), and stent thrombosis (ST) at five years were compared between the two gender groups. In the two groups, women had higher proportions of clinical risk factors, such as being elderly, diabetes mellitus, hypertension and hyperlipidemia, compared to men. Besides, the mean target vessel number per patient was higher and the mean reference vessel diameter smaller for women. Men had higher risks of cardiac death (3.7% vs. 1.6%, P = 0.021) and MACE (8.4% vs. 4.7%, P = 0.004) at five years compared with women. However, the cumulative hazards of non-fatal MI and TLR were similar between men and women. The incidence of Academic Research Consortium (ARC) definite or probable stent thrombosis was similar between the two groups (1.3% vs. 1.0%, P = 0.639). Prolonged clopidogrel therapy (>6 months) did not reduce the cumulative hazards of ST from six months to five years in both men (χ(2) = 0.098, log rank P = 0.754) and women (χ(2) = 2.043, log rank P = 0.153) patients. Women had a lower MACE and cardiac death rate than men after

  2. Intravascular imaging comparison of two metallic limus-eluting stents abluminally coated with biodegradable polymers: IVUS and OCT results of the DESTINY trial.

    Science.gov (United States)

    Costa, J Ribamar; Chamié, Daniel; Abizaid, Alexandre A C; Ribeiro, Expedito; Meireles, George C; Prudente, Maurício; Campos, Carlos A; Castro, Juliana P; Costa, Ricardo; Lemos, Pedro A

    2017-02-01

    We sought to compare, by means of IVUS and OCT imaging, the performance of a novel sirolimus-eluting drug-eluting stent (DES) with biodegradable polymer (Inspiron™) to the Biomatrix™ DES. From the DESTINY trial, a total of 70 randomized patients (2:1) were enrolled in the IVUS substudy (Inspiron™, n = 46; Biomatrix™: n = 20) while 25 patients were evaluated with OCT (Inspiron™, n = 19; Biomatrix™: n = 06) at 9-month follow-up. The main endpoints were % of neointimal tissue obstruction (IVUS) and neointimal stut coverage (OCT) at 9 months. Patients treated with both DES had very little NIH formation at 9 months either by IVUS (% of NIH obstruction of 4.9 ± 4.1 % with Inspiron™ vs. 2.7 ± 2.9 % with Biomatrix™, p = 0.03) or by OCT (neointimal thickness of 144.2 ± 72.5 µm Inspiron™ vs. 115.0 ± 53.9 µm with Biomatrix™, p = 0.45). Regarding OCT strut-level assessment, again both devices showed excellent 9-month performance, with high rates of strut coverage (99.49 ± 1.01 % with Inspiron™ vs. 97.62 ± 2.21 % with Biomatrix™, p < 0.001) and very rare malapposition (0.29 ± 1.06 % with Inspiron™ vs. 0.53 ± 0.82 % with Biomatrix™, p = 0.44). Patients with any uncovered struts were more frequently identified in the Biomatrix™ group (9.78 ± 7.13 vs. 2.29 ± 3.91 %, p < 0.001). In the present study, midterm IVUS and OCT evaluations showed that both new generation DES with biodegradable polymer were effective in terms of suppressing excessive neointimal response, with very high rates of apposed and covered struts, suggesting a consistent and benign healing pattern.

  3. Concanavalin A immobilized magnetic poly(glycidyl methacrylate) beads for prostate specific antigen binding.

    Science.gov (United States)

    Idil, Neslihan; Perçin, Işık; Karakoç, Veyis; Yavuz, Handan; Aksöz, Nilüfer; Denizli, Adil

    2015-10-01

    The aim of this study was to prepare Concanavalin A (Con A) immobilized magnetic poly(glycidyl methacrylate) (mPGMA) beads for prostate specific antigen (PSA) binding and to study binding capacities of the beads using lectin-glycoprotein interactions. Firstly, iron oxide nanoparticles were synthesized by co-precipitation method and then, beads were synthesized by dispersion polymerization in the presence of iron oxide nanoparticles. Con A molecules were both covalently immobilized onto the beads directly and through the spacer arm (1,6-diaminohexane-HDMA). The total PSA and free PSA binding onto the mPGMA-HDMA-Con A beads were higher than that of the mPGMA-Con A beads. Maximum PSA binding capacity was observed as 91.2 ng/g. Approximately 45% of the bound PSA was eluted by using 0.1 M mannose as elution agent. The mPGMA-HDMA-Con A beads could be reused without a remarkable decrease in the binding capacities after 5 binding-desorption cycles. Serum fractions were analyzed using SDS-PAGE. The mPGMA-HDMA-Con A beads could be useful for the detection of PSA and suggested as a model system for other glycoprotein biomarkers. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. In-bead screening

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to screening of one-bead-one-compound (OBOC) combinatorial libraries which is useful for the discovery of compounds displaying molecular interactions with a biological or a physicochemical system, such as substrates and inhibitors of enzymes and the like. The invention...... provides a method for screening a library of compounds for their interaction with a physico- chemical or biological system and a corresponding kit for performing the method of screening a one-bead-one-compound library of compounds....

  5. Effect of algal density in bead, bead size and bead concentrations ...

    African Journals Online (AJOL)

    Laboratory experiments were performed to study nitrogen and phosphorus uptake by the unicellular green microalga Chlorella vulgaris immobilized in calcium alginate beads. Different cell stockings in beads, different bead sizes and different algal bead concentrations in wastewaters were tested. Significant higher nutrients ...

  6. Drug-eluting stent thrombosis: results from the multicenter Spanish registry ESTROFA (Estudio ESpañol sobre TROmbosis de stents FArmacoactivos).

    Science.gov (United States)

    de la Torre-Hernández, José M; Alfonso, Fernando; Hernández, Felipe; Elizaga, Jaime; Sanmartin, Marcelo; Pinar, Eduardo; Lozano, Iñigo; Vazquez, Jose M; Botas, Javier; Perez de Prado, Armando; Hernández, Jose M; Sanchis, Juan; Nodar, Juan M Ruiz; Gomez-Jaume, Alfredo; Larman, Mariano; Diarte, Jose A; Rodríguez-Collado, Javier; Rumoroso, Jose R; Lopez-Minguez, Jose R; Mauri, Josepa

    2008-03-11

    This study sought to assess the incidence, predictors, and outcome of drug-eluting stent(DES) thrombosis in real-world clinical practice. The DES thromboses in randomized trials could not be comparable to those observed in clinical practice, frequently including off-label indications. We designed a large-scale, nonindustry-linked multicentered registry, with 20 centers in Spain. The participant centers provided follow-up data for their patients treated with DES, reporting a detailed standardized form in the event of any angiography-documented DES-associated thrombosis occurring. Of 23,500 patients treated with DES, definite stent thrombosis(ST) developed in 301: 24 acute, 125 subacute, and 152 late. Of the late, 62 occurred >1 year(very late ST). The cumulative incidence was 2% at 3 years. Antiplatelet treatment had been discontinued in 95 cases(31.6%). No differences in incidences were found among stent types. Independent predictors for subacute ST analyzed in a subgroup of 14,120 cases were diabetes, renal failure, acute coronary syndrome, ST-segment elevation myocardial infarction, stent length, and left anterior descending artery stenting, and for late ST were ST-segment elevation myocardial infarction, stenting in left anterior descending artery, and stent length. Mortality at 1-year follow-up was 16% and ST recurrence 4.6%. Older age, left ventricular ejection fraction <45%, nonrestoration of Thrombolysis In Myocardial Infarction flow grade 3, and additional stenting were independent predictors for mortality. The cumulative incidence of ST after DES implantation was 2% at 3 years. No differences were found among stent types. Patient profiles differed between early and late ST. Short-term prognosis is poor, especially when restoration of normal flow fails.

  7. Developement of Spherical Polyurethane Beads

    Institute of Scientific and Technical Information of China (English)

    K. Maeda; H. Ohmori; H. Gyotoku

    2005-01-01

    @@ 1Results and Discussion We established a new method to produce the spherical polyurethane beads which have narrower distribution of particle size. This narrower distribution was achieved by the polyurethane prepolymer which contains ketimine as a blocked chain-extending agent. Firstly, the prepolymer is dispersed into the aqueous solution containing surfactant. Secondaly, water comes into the inside of prepolymer as oil phase. Thirdly, ketimine is hydrolyzed to amine, and amine reacts with prepolymer immediately to be polyurethane.Our spherical polyurethane beads are very suitable for automotive interior parts especially for instrument panel cover sheet producing under the slush molding method, because of good process ability, excellent durability to the sunlight and mechanical properties at low temperature. See Fig. 1 ,Fig. 2 and Fig. 3 (Page 820).

  8. Sangadzhi Kononov, Buddhist Prayer Beads

    OpenAIRE

    Churyumov, Anton; Kovaeva, Bair

    2016-01-01

    Prayer beads have special dividers that divide the beads into 7, 21 and 33. Apart from using in prayers, the Kalmyks also keep beads as amulets that are believed to have strong energy. After prayers, old people often bless their children and grandchildren with their beads. Such beads are also kept in families from one generation to the next. Sangadzhi believes that prayer beads store inside them the energy of mantras that have been read with them. There is an interesting story about the pray...

  9. Half bead welding technique

    International Nuclear Information System (INIS)

    Canonico, D.A.; Holz, P.P.

    1978-05-01

    The ORNL has employed the Section XI half-bead procedure for six repair welds. Table 2 identifies the repairs and the components upon which they were accomplished. The weld repairs were performed to permit us to evaluate material properties, residual stresses, weld repair procedures, and structural behavior of repaired pressure vessels. As a consequence of our study we concluded that when the half bead procedure is correctly applied: (1) there is no metallurgical degradation of the base material, (2) residual stresses of yield point magnitude will be present, and (3) the structural integrity of the pressure vessel is not impaired at Charpy V-notch upper shelf temperatures

  10. Blood Compatibility of Sulfonated Cladophora Nanocellulose Beads

    Directory of Open Access Journals (Sweden)

    Igor Rocha

    2018-03-01

    Full Text Available Sulfonated cellulose beads were prepared by oxidation of Cladophora nanocellulose to 2,3-dialdehyde cellulose followed by sulfonation using bisulfite. The physicochemical properties of the sulfonated beads, i.e., high surface area, high degree of oxidation, spherical shape, and the possibility of tailoring the porosity, make them interesting candidates for the development of immunosorbent platforms, including their application in extracorporeal blood treatments. A desired property for materials used in such applications is blood compatibility; therefore in the present work, we investigate the hemocompatibility of the sulfonated cellulose beads using an in vitro whole blood model. Complement system activation (C3a and sC5b-9 levels, coagulation activation (thrombin-antithrombin (TAT levels and hemolysis were evaluated after whole blood contact with the sulfonated beads and the results were compared with the values obtained with the unmodified Cladophora nanocellulose. Results showed that neither of the cellulosic materials presented hemolytic activity. A marked decrease in TAT levels was observed after blood contact with the sulfonated beads, compared with Cladophora nanocellulose. However, the chemical modification did not promote an improvement in Cladophora nanocellulose hemocompatibility in terms of complement system activation. Even though the sulfonated beads presented a significant reduction in pro-coagulant activity compared with the unmodified material, further modification strategies need to be investigated to control the complement activation by the cellulosic materials.

  11. Blood Compatibility of Sulfonated Cladophora Nanocellulose Beads.

    Science.gov (United States)

    Rocha, Igor; Lindh, Jonas; Hong, Jaan; Strømme, Maria; Mihranyan, Albert; Ferraz, Natalia

    2018-03-07

    Sulfonated cellulose beads were prepared by oxidation of Cladophora nanocellulose to 2,3-dialdehyde cellulose followed by sulfonation using bisulfite. The physicochemical properties of the sulfonated beads, i.e., high surface area, high degree of oxidation, spherical shape, and the possibility of tailoring the porosity, make them interesting candidates for the development of immunosorbent platforms, including their application in extracorporeal blood treatments. A desired property for materials used in such applications is blood compatibility; therefore in the present work, we investigate the hemocompatibility of the sulfonated cellulose beads using an in vitro whole blood model. Complement system activation (C3a and sC5b-9 levels), coagulation activation (thrombin-antithrombin (TAT) levels) and hemolysis were evaluated after whole blood contact with the sulfonated beads and the results were compared with the values obtained with the unmodified Cladophora nanocellulose. Results showed that neither of the cellulosic materials presented hemolytic activity. A marked decrease in TAT levels was observed after blood contact with the sulfonated beads, compared with Cladophora nanocellulose. However, the chemical modification did not promote an improvement in Cladophora nanocellulose hemocompatibility in terms of complement system activation. Even though the sulfonated beads presented a significant reduction in pro-coagulant activity compared with the unmodified material, further modification strategies need to be investigated to control the complement activation by the cellulosic materials.

  12. Discrete dipole approximation simulation of bead enhanced diffraction grating biosensor

    International Nuclear Information System (INIS)

    Arif, Khalid Mahmood

    2016-01-01

    We present the discrete dipole approximation simulation of light scattering from bead enhanced diffraction biosensor and report the effect of bead material, number of beads forming the grating and spatial randomness on the diffraction intensities of 1st and 0th orders. The dipole models of gratings are formed by volume slicing and image processing while the spatial locations of the beads on the substrate surface are randomly computed using discrete probability distribution. The effect of beads reduction on far-field scattering of 632.8 nm incident field, from fully occupied gratings to very coarse gratings, is studied for various bead materials. Our findings give insight into many difficult or experimentally impossible aspects of this genre of biosensors and establish that bead enhanced grating may be used for rapid and precise detection of small amounts of biomolecules. The results of simulations also show excellent qualitative similarities with experimental observations. - Highlights: • DDA was used to study the relationship between the number of beads forming gratings and ratio of first and zeroth order diffraction intensities. • A very flexible modeling program was developed to design complicated objects for DDA. • Material and spatial effects of bead distribution on surfaces were studied. • It has been shown that bead enhanced grating biosensor can be useful for fast detection of small amounts of biomolecules. • Experimental results qualitatively support the simulations and thus open a way to optimize the grating biosensors.

  13. Thrombosis of second-generation drug-eluting stents in real practice results from the multicenter Spanish registry ESTROFA-2 (Estudio Español Sobre Trombosis de Stents Farmacoactivos de Segunda Generacion-2).

    Science.gov (United States)

    de la Torre Hernández, José M; Alfonso, Fernando; Gimeno, Federico; Diarte, Jose A; Lopez-Palop, Ramón; Pérez de Prado, Armando; Rivero, Fernando; Sanchis, Juan; Larman, Mariano; Diaz, Jose F; Elizaga, Jaime; Moreiras, Javier Martín; Gomez Jaume, Alfredo; Hernández, José M; Mauri, Josepa; Recalde, Angel Sánchez; Bullones, Juan A; Rumoroso, Jose R; Del Blanco, Bruno García; Baz, Jose A; Bosa, Francisco; Botas, Javier; Hernández, Felipe

    2010-09-01

    This study sought to evaluate second-generation drug-eluting stent (DES) thrombosis in clinical practice. First-generation DES are associated with a significant incidence of late thrombosis. There is paucity of data regarding real practice late thrombosis incidence and predictors with second-generation DES, zotarolimus-eluting stent (ZES), and everolimus-eluting stents (EES). A prospective, large-scale, non-industry-linked multicenter registry was designed. Complete clinical-procedural data and systematic follow-up of all patients treated with these stents was reported in a dedicated registry supported by the Spanish Working Group on Interventional Cardiology. From 2005 to 2008, 4,768 patients were included in 34 centers: 2,549 treated with ZES, and 2,219 with EES. The cumulative incidence of definite/probable thrombosis for ZES was 1.3% at 1 year and 1.7% at 2 years and for EES 1.4% at 1 year and 1.7% at 2 years (p = 0.8). The increment of definite thrombosis between the first and second year was 0.2% and 0.25%, respectively. In a propensity score analysis, the incidence remained very similar. Ejection fraction (adjusted hazard ratio [HR]: 0.97; 95% confidence interval [CI]: 0.95 to -0.99; p = 0.008), stent diameter (adjusted HR: 0.37; 95% CI: 0.17to 0.81; p = 0.01) and bifurcations (adjusted HR: 2.1; 95% CI: 1.14 to 3.7; p = 0.02) emerged as independent predictors of thrombosis. In the subgroup of patients with bifurcations, the use of ZES was independently associated with a higher thrombosis rate (adjusted HR: 4; 95% CI: 1.1 to 13; p = 0.03). In a real practice setting, the incidence of thrombosis at 2 years with ZES and EES was low and quite similar. The incidence of very late thrombosis resulted lower than was reported in registries of first-generation DES. In the subset of bifurcations, the use of ZES significantly increased the risk of thrombosis. Copyright © 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Microfluidic magnetic bead conveyor belt

    NARCIS (Netherlands)

    van Pelt, S.; Frijns, A.J.H.; den Toonder, J.M.J.

    2017-01-01

    Magnetic beads play an important role in the miniaturization of clinical diagnostics systems. In lab-on-chip platforms, beads can be made to link to a target species and can then be used for the manipulation and detection of this species. Current bead actuation systems utilize complex on-chip coil

  15. Configurational Statistics of Magnetic Bead Detection with Magnetoresistive Sensors

    DEFF Research Database (Denmark)

    Henriksen, Anders Dahl; Ley, Mikkel Wennemoes Hvitfeld; Flyvbjerg, Henrik

    2015-01-01

    Magnetic biosensors detect magnetic beads that, mediated by a target, have bound to a functionalized area. This area is often larger than the area of the sensor. Both the sign and magnitude of the average magnetic field experienced by the sensor from a magnetic bead depends on the location...... of the bead relative to the sensor. Consequently, the signal from multiple beads also depends on their locations. Thus, a given coverage of the functionalized area with magnetic beads does not result in a given detector response, except on the average, over many realizations of the same coverage. We present...... a systematic theoretical analysis of how this location-dependence affects the sensor response. The analysis is done for beads magnetized by a homogeneous in-plane magnetic field. We determine the expected value and standard deviation of the sensor response for a given coverage, as well as the accuracy...

  16. Coated Aerogel Beads

    Science.gov (United States)

    Littman, Howard (Inventor); Plawsky, Joel L. (Inventor); Paccione, John D. (Inventor)

    2014-01-01

    Methods and apparatus for coating particulate material are provided. The apparatus includes a vessel having a top and a bottom, a vertically extending conduit having an inlet in the vessel and an outlet outside of the vessel, a first fluid inlet in the bottom of the vessel for introducing a transfer fluid, a second fluid inlet in the bottom of the vessel for introducing a coating fluid, and a fluid outlet from the vessel. The method includes steps of agitating a material, contacting the material with a coating material, and drying the coating material to produce a coated material. The invention may be adapted to coat aerogel beads, among other materials. A coated aerogel bead and an aerogel-based insulation material are also disclosed.

  17. Elution of Monomers from Provisional Composite Materials

    Directory of Open Access Journals (Sweden)

    Simon Daniel Schulz

    2015-01-01

    Full Text Available The aim of this study was to evaluate the elution of substances from different materials used for the manufacturing of temporary indirect restorations, after storage in saliva and ethanol 75%. 10 samples of three chemically cured materials (Protemp 3 Garant, Systemp.c&b, and Trim and one light-cured material (Clip F were stored in saliva and ethanol 75% for 24 h, 7, and days 28 days. From the storage media at each time period, samples were prepared and analysed by LC-MS/MS, in order to access the elution of monomers. The results differed among the materials (P ≤ 0.05. No monomers were detected in the samples of Protemp 3 Garant and Clip F. Substances were detected only in ethanol samples of Systemp.c&b and Trim. The amount of BisGMA, TEGDMA, and UDMA 2 released from Systemp.c&b was higher compared to Trim. Storage time affected the release of substances (P ≤ 0.05. The highest release was observed within the first 24 h. It can be concluded that provisional resin composite materials do not show high release of monomers and this release is material dependent. However, the detection of additional peaks during the analysis, suggesting the formation of by-products of the eluted substances, may not be in favour of these materials with respect to their toxicity.

  18. Left ventricular contractile function after distal protection in primary percutaneous coronary intervention Results from the Drug Elution and Distal Protection in ST-Elevation Myocardial Infarction trial

    DEFF Research Database (Denmark)

    Kofoed, K F; Kelbæk, H; Thuesen, L

    2011-01-01

    Coronary intervention (PCI) may result in an increased infarct size. We evaluated the effect of distal protection during PCI for ST-segment elevation myocardial infarction (STEMI) on myocardial function.......Coronary intervention (PCI) may result in an increased infarct size. We evaluated the effect of distal protection during PCI for ST-segment elevation myocardial infarction (STEMI) on myocardial function....

  19. Evaluation on elution feature of bentonite buffer materials

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, Hirohisa; Kanno, Takeshi; Matsumoto, Kazuhiro

    1997-09-01

    In order to evaluate long term physical stability of artificial barrier in land disposal of high level radioactive wastes, it is necessary to know quantitatively elution behavior of buffering materials from disposal road (or cavity) to circumferential rock crack. When elution of the buffer material occurs on large scale, amount of bentonite in the disposal road (or cavity) reduces and reduction of various functions expected to the buffer materials is presumed. According to specification examples of road transverse arrangement and disposal vertical arrangement systems, evaluation on elution amount of the buffer materials at disposal environment was conducted. Opening width of rock crack in the disposal environment was supposed to be 0.5 mm. As a result, obtained mass elution ratios of the buffer materials due to extrusion phenomenon were 0.04 to 0.2% after 10,000 year and 2 to 12% after 1,000,000 years. (G.K.)

  20. New Nanoparticles Dispersing Beads Mill with Ultra Small Beads and its Application

    International Nuclear Information System (INIS)

    Inkyo, M; Tahara, T; Imajyo, Y

    2011-01-01

    Two of the major problems related to nanoparticle dispersion with a conventional beads mill are re-agglomeration and damage to the crystalline structure of the particles. The Ultra Apex Mill was developed to solve these problems by enabling the use of ultra-small beads with a diameter of less than 0.1mm. The core of this breakthrough development is centrifugation technology which allows the use of beads as small as 0.015mm. When dispersing agglomerated nanoparticles the impulse of the small beads is very low which means there is little influence on the particles. The surface energy of the nanoparticles remains low so the properties are not likely to change. As a result, stable nanoparticle dispersions can be achieved without re-cohesion. The Ultra Apex Mill is superior to conventional beads mills that are limited to much larger bead sizes. The technology of the Ultra Apex Mill has pioneered practical applications for nanoparticles in various fields: composition materials for LCD screens, ink-jet printing, ceramic condensers and cosmetics.

  1. Friction of N-bead macromolecules in solution: Effects of the bead-solvent interaction

    International Nuclear Information System (INIS)

    Uvarov, Alexander; Fritzsche, Stephan

    2006-01-01

    The role of the bead-solvent interaction has been studied for its influence on the dynamics of an N-bead macromolecule which is immersed into a solution. Using a Fokker-Planck equation for the phase-space distribution function of the macromolecule, we show that all the effects of the solution can be treated entirely in terms of the friction tensors which are assigned to each pair of interacting beads in the chain. For the high-density as well as for the critical solvent, the properties of these tensors are discussed in detail and are calculated by using several (realistic) choices of the bead-solvent potential. From the friction tensors, moreover, an expression for the center-of-mass friction coefficient of a (N-bead) chain macromolecule is derived. Numerical data for this coefficient for 'truncated' Lennard-Jones bead-solvent potential are compared with results from molecular dynamic simulations and from the phenomenological theoretical data as found in the literature

  2. Cooling Rates of Lunar Volcanic Glass Beads

    Science.gov (United States)

    Hui, Hejiu; Hess, Kai-Uwe; Zhang, Youxue; Peslier, Anne; Lange, Rebecca; Dingwell, Donald; Neal, Clive

    2016-01-01

    It is widely accepted that the Apollo 15 green and Apollo 17 orange glass beads are of volcanic origin. The diffusion profiles of volatiles in these glass beads are believed to be due to degassing during eruption (Saal et al., 2008). The degree of degassing depends on the initial temperature and cooling rate. Therefore, the estimations of volatiles in parental magmas of lunar pyroclastic deposits depend on melt cooling rates. Furthermore, lunar glass beads may have cooled in volcanic environments on the moon. Therefore, the cooling rates may be used to assess the atmospheric condition in an early moon, when volcanic activities were common. The cooling rates of glasses can be inferred from direct heat capacity measurements on the glasses themselves (Wilding et al., 1995, 1996a,b). This method does not require knowledge of glass cooling environments and has been applied to calculate the cooling rates of natural silicate glasses formed in different terrestrial environments. We have carried out heat capacity measurements on hand-picked lunar glass beads using a Netzsch DSC 404C Pegasus differential scanning calorimeter at University of Munich. Our preliminary results suggest that the cooling rate of Apollo 17 orange glass beads may be 12 K/min, based on the correlation between temperature of the heat capacity curve peak in the glass transition range and glass cooling rate. The results imply that the parental magmas of lunar pyroclastic deposits may have contained more water initially than the early estimations (Saal et al., 2008), which used higher cooling rates, 60-180 K/min in the modeling. Furthermore, lunar volcanic glass beads could have been cooled in a hot gaseous medium released from volcanic eruptions, not during free flight. Therefore, our results may shed light on atmospheric condition in an early moon.

  3. The Indicating FTA Elute Cartridge

    Science.gov (United States)

    de Bie, Roosmarie P.; Schmeink, Channa E.; Bakkers, Judith M.J.E.; Snijders, Peter J.F.; Quint, Wim G.V.; Massuger, Leon F.A.G.; Bekkers, Ruud L.M.; Melchers, Willem J.G.

    2011-01-01

    The clinically validated high-risk human papillomavirus (hrHPV) Hybrid Capture 2 (HC2) and GP5+/6+-PCR assays were analyzed on an Indicating FTA Elute cartridge (FTA cartridge). The FTA cartridge is a solid dry carrier that allows safe transport of cervical samples. FTA cartridge samples were compared with liquid-based samples for hrHPV and high-grade cervical intraepithelial neoplasia (CIN) detection. One cervical sample was collected in a liquid-based medium, and one was applied to the FTA cartridge. DNA was eluted directly from the FTA cartridge by a simple elution step. HC2 and GP5+/6+-PCR assays were performed on both the liquid-based and the FTA-eluted DNA of 88 women. Overall agreement between FTA and liquid-based samples for the presence of hrHPV was 90.9% with GP5+/6+-PCR and 77.3% with HC2. The sensitivity for high-grade CIN of hrHPV testing on the FTA cartridges was 84.6% with GP5+/6+-PCR and only 53.8% with HC2. By comparison, these sensitivities on liquid-based samples were 92.3% and 100% for GP5+/6+-PCR and HC2, respectively. Therefore, the FTA cartridge shows reasonably good overall agreement for hrHPV detection with liquid-based media when using GP5+/6+-PCR but not HC2 testing. Even with GP5+/6+-PCR, the FTA cartridge is not yet capable of detecting all high-grade CIN lesions. PMID:21704269

  4. Elution of Artificial Sputum from Swab by Rotating Magnetic Field-Induced Mechanical Impingement

    Directory of Open Access Journals (Sweden)

    Shubham Banik

    2017-12-01

    Full Text Available Cotton-tipped applicator swabs are used as a collection device for many biological samples and its complete elution is a desired step for clinical and forensic diagnostics. Swabs are used to collect infectious body fluids, where the concentration of pathogens can range from 1 × 104 CFU/mL (colony forming units/mL in respiratory-tract infections and 1 × 105 in urinary-tract infections, to up to 1 × 109 CFU/mL in salivary samples. These samples are then eluted and lysed, prior to DNA (De-oxy Ribonucleic Acid analysis. The recovery of micro-organisms from a matrix of swab fibres depends on the nature of the body fluid, the type of the swab fibres, and the process of elution. Various methods to elute samples from swab include chemical digestion of fibres (~20% recovery, centrifugation (~58% recovery, piezoelectric vibration, or pressurized fluid-flow (~60% recovery. This study reports a magnetically-actuated physical impingement method for elution and recovery of artificial sputum samples from cotton fibres. A device has been fabricated to induce a rotating magnetic field on smaller magnetic particles in a vial that strikes the swab within a confined gap. Elution from the swab in this device was characterized using 2% Methyl cellulose in deionised water, loaded with fluorescent-tagged polystyrene beads and E. coli at various concentrations. The recovery efficiency was found to increase with both rotational speed and elution time, but plateaus after 400 RPM (Revolutions per minute and 120 s, respectively. At a higher concentration of polystyrene beads (5 × 108 particles/mL, a maximum recovery of ~85% was achieved. With lower concentration, (1 × 105 particles/mL the maximum efficiency (~92.8% was found to be almost twice of passive elution (46.7%. In the case of E. coli, the corresponding recovery efficiency at 3.35 × 105 CFU/mL is 90.4% at 500 RPM and 120 s. This elution method is expected to have a wide applicability in clinical diagnostics.

  5. Design of systems for handling radioactive ion exchange resin beads

    International Nuclear Information System (INIS)

    Shapiro, S.A.; Story, G.L.

    1979-01-01

    The flow of slurries in pipes is a complex phenomenon. There are little slurry data available on which to base the design of systems for radioactive ion exchange resin beads and, as a result, the designs vary markedly in operating plants. With several plants on-line, the opportunity now exists to evaluate the designs of systems handling high activity spent resin beads. Results of testing at Robbins and Meyers Pump Division to quantify the behavior of resin bead slurries are presented. These tests evaluated the following slurry parameters; resin slurry velocity, pressure drop, bead degradation, and slurry concentration effects. A discussion of the general characteristics of resin bead slurries is presented along with a correlation to enable the designer to establish the proper flowrate for a given slurry composition and flow regime as a function of line size. Guidelines to follow in designing a resin handling system are presented

  6. Microfabricated Passive Magnetic Bead separators

    DEFF Research Database (Denmark)

    Hansen, Mikkel Fougt; Lund-Olesen, Torsten; Smistrup, Kristian

    2006-01-01

    The use and manipulation of functionalized magnetic beads for bioanalysis in lab-on-a-chip systems is receiving growing interest. We have developed microfluidic systems with integrated magnetic structures for the capture and release of magnetic beads. The systems are fabricated in silicon by deep...

  7. bEADS

    DEFF Research Database (Denmark)

    Williams, Peter Leslie; Overholt, Daniel

    2017-01-01

    While there are a great variety of digital musical interfaces available to the working musician, few offer the level of immediate, nuanced and instinctive interaction that one finds in an acoustic shaker. bEADS is a prototype of a digital musical instrument that utilises the gestural vocabulary...... associated with shaken idiophones and expands on the techniques and sonic possibilities associated with them. By using a bespoke physically informed synthesis engine, in conjunction with accelerometer and pressure sensor data, an actuated handheld instrument has been built that allows for quickly switching...... between widely differing percussive sound textures. The prototype has been evaluated by three experts with different levels of involvement in professional music making....

  8. Graphene Oxide Conjugated Magnetic Beads for RNA Extraction.

    Science.gov (United States)

    Pham, Xuan-Hung; Baek, Ahruem; Kim, Tae Han; Lee, Sang Hun; Rho, Won-Yeop; Chung, Woo-Jae; Kim, Dong-Eun; Jun, Bong-Hyun

    2017-08-04

    A magnetic material that consists of silica-coated magnetic beads conjugated with graphene oxide (GO) was successfully prepared for facile ribonucleic acid (RNA) extraction. When the GO-modified magnetic beads were applied to separate the RNA from the lysed cell, the cellular RNAs were readily adsorbed to and readily desorbed from the surface of the GO-modified magnetic beads by urea. The amount of RNA extracted by the GO-modified magnetic beads was ≈170 % as much as those of the control extracted by a conventional phenol-based chaotropic solution. These results demonstrate that the facile method of RNA separation by using GO-modified magnetic beads as an adsorbent is an efficient and simple way to purify intact cellular RNAs and/or microRNA from cell lysates. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Oxytetracycline removal from water by novel microbial embedding gel beads

    Science.gov (United States)

    Wu, Nan; Pan, Peng; Zeng, Ming; Wang, Wei; Xu, Chenshan; Zhang, Zongpeng; Liu, Xinyuan; Wang, Yichao

    2018-01-01

    As a common antibiotic in aquatic environment, excessive oxytetracycline (OTC) is urgent to be removed due to its great biological toxicity. Compared with the traditional activated sludge, microbial embedding can enhance the treating efficiency. In this study, novel microbial embedding gel beads were produced with the additional agent of cyclodextrin (CD). Results show that CD could increase the mass transfer of OTC into gel beads, possibly because of its strong affinity for organic matters. In terms of OTC biodegradation, gel beads with CD were comparable to gel beads without CD, while the former’s sucrose removal efficiency was higher than the latter. The biodegradation of OTC only occurred in the presence of sucrose. The respiration test also confirmed these findings. Overall, the produced novel gel beads modified with CD could improve the removal performance of OTC.

  10. Long-Term Effectiveness of the Zilver PTX Drug-Eluting Stent for Femoropopliteal Peripheral Artery Disease in Patients with No Patent Tibial Runoff Vessels-Results from the Zilver PTX Japan Post-Market Surveillance Study.

    Science.gov (United States)

    Cipollari, Stefano; Yokoi, Hiroyoshi; Ohki, Takao; Kichikawa, Kimihiko; Nakamura, Masato; Komori, Kimihiro; Nanto, Shinsuke; O'Leary, Erin E; Lottes, Aaron E; Saunders, Alan T; Dake, Michael D

    2018-01-01

    To evaluate 2-year results of the Zilver PTX (Cook Medical, Bloomington, Indiana) drug-eluting stent (DES) for femoropopliteal peripheral artery disease (PAD) in patients with no continuous patent infrapopliteal runoff arteries compared with patients with ≥ 1 continuous patent runoff vessels. A retrospective analysis of patients with femoropopliteal PAD enrolled in the Zilver PTX Post-Market Surveillance Study in Japan was performed. There were no exclusion criteria. Outcomes, including freedom from target lesion revascularization (TLR), patency, and clinical benefit, for the no-runoff group (n = 54) were compared with the runoff group (n = 846). The 2 groups were similar in terms of demographics, lesion characteristics, and comorbidities (P > .05). There was a higher incidence of critical limb ischemia in the no-runoff group compared with the runoff group (44.8% vs 19.7%; P < .01). There were 3 amputations (5.6%) in the no-runoff group versus 7 amputations (0.8%) in the runoff group (P = .02). At 2 years, freedom from TLR rates were 81.3% versus 83.8% (P = .87), patency rates were 68.4% versus 70.7% (P = .95), and clinical benefit rates were 73.7% versus 80.0% (P = .16) in the no-runoff versus runoff group, respectively. Results in patients with no continuous patent tibial runoff were favorable through 2 years and similar to results for patients with ≥ 1 continuous patent runoff vessels, indicating that the Zilver PTX DES may be a valid treatment option for patients with these difficult-to-treat lesions. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  11. A new affinity-HPLC packing for protein separation: Cibacron blue attached uniform porous poly(HEMA-co-EDM) beads.

    Science.gov (United States)

    Unsal, Ender; Durdu, Aysun; Elmas, Begum; Tuncel, Murvet; Tuncel, Ali

    2005-11-01

    In this study, a new affinity high-performance liquid chromatography (HPLC) stationary phase suitable for protein separation was synthesized. In the first stage of the synthesis, uniform porous poly(2-hydroxyethyl methacrylate-co-ethylene dimethacrylate), poly(HEMA-co-EDM), beads 6.2 mum in size were obtained. Homogeneous distribution of hydroxyl groups in the bead interior was confirmed by confocal laser scanning microscopy. The plain poly(HEMA-co-EDM) particles gave very low non-specific protein adsorption with albumin. The selected dye ligand Cibacron blue F3G-A (CB F3G-A) was covalently linked onto the beads via hydroxyl groups. In the batch experiments, albumin adsorption up to 60 mg BSA/g particles was obtained with the CB F3G-A carrying poly(HEMA-co-EDM) beads. The affinity-HPLC of selected proteins (albumin and lysozyme) was investigated in a 25 mm x 4.0-mm inner diameter column packed with CB F3G-A carrying beads and both proteins were successfully resolved. By a single injection, 200 mug of protein was loaded and quantitatively eluted from the column. The protein recovery increased with increasing flow rate and salt concentration of the elution buffer and decreased with the increasing protein feed concentration. During the albumin elution, theoretical plate numbers up to 30,000 plates/m were achieved by increasing the salt concentration.

  12. The stenting strategy of drug-eluting stents for coronary artery disease in patients on dialysis

    Directory of Open Access Journals (Sweden)

    Hiroshi Fujita

    2014-12-01

    Full Text Available Background: Reports regarding the relationship between the length and diameter of implanted drug-eluting stents and clinical and angiographic outcomes in dialysis patients are limited. Aim: We investigated the efficiency of drug-eluting stents for coronary artery disease in patients on dialysis from the viewpoint of stent sizing. Methods: Sirolimus-eluting stents were implanted in 88 lesions and bare metal stents were implanted in 43 lesions. We compared stenting strategy, major adverse cardiac events, and angiographic results between sirolimus-eluting stent and bare metal stent groups. Results: Stent diameter was smaller and stent length was longer in the sirolimus-eluting stent group than in the bare metal stent group in our routine practices. There was no significant between-group difference in late diameter loss. Rates of angiographic restenosis and target lesion revascularization were significantly higher in the sirolimus-eluting stent group than in the bare metal stent group. Although stent length was significantly longer and stent diameter was smaller in the sirolimus-eluting stent group, sirolimus-eluting stents did not improve the subsequent clinical and angiographic results compared with bare metal stents in dialysis patients. Conclusion: In dialysis patients, a longer length and/or smaller diameter sirolimus-eluting stent implantation was associated with high rates of restenosis and target lesion revascularization compared with bare metal stents.

  13. Comparison between simulation and experimentally observed interactions between two magnetic beads in a fluidic system

    Energy Technology Data Exchange (ETDEWEB)

    Oduwole, Olayinka, E-mail: olayinka.oduwole@eng.ox.ac.uk; Grob, David Tim, E-mail: tim.grob@eng.ox.ac.uk; Sheard, Steve, E-mail: steve.sheard@eng.ox.ac.uk

    2016-06-01

    Continuous flow separation of magnetic particles within a microfluidic device could lead to improved performance of magnetic bead-based assays but the undesirable formation of bead clusters reduces its efficiency; this efficiency refers to the ability to separate bound magnetic beads from a mixture of particles. Such agglomerates are formed due to magnetic binding forces while hydrodynamic interactions strongly influence the particles' movement. This paper presents a model for interactions between a pair of equal sized super-paramagnetic beads suspended in water within a uniform magnetic field. To the best of our knowledge, we present for the first time a comparison between simulated trajectories and the beads' movement captured on video; the beads were suspended in a stationary fluid placed within a uniform magnetic field. In conclusion, the model is a good approximation for beads interacting with their nearest neighbours and is able to predict the trajectory pattern of these particles in a magnetic bead-based assay. Predicting the magnetically induced interaction of nearby beads will help in determining the density of beads in an assay and in avoiding agglomeration over a fixed time duration. - Highlights: • We modelled the interactions between a pair of super-paramagnetic beads suspended in water within a uniform magnetic field. • We tracked the movement of the bead pair and captured it on video. • We compared the numerical results with the video data and achieved a good agreement. • We predicted the agglomeration time as a function of the separation distance.

  14. Strategies for enumeration of circulating microvesicles on a conventional flow cytometer: Counting beads and scatter parameters.

    Science.gov (United States)

    Alkhatatbeh, Mohammad J; Enjeti, Anoop K; Baqar, Sara; Ekinci, Elif I; Liu, Dorothy; Thorne, Rick F; Lincz, Lisa F

    2018-01-01

    Enumeration of circulating microvesicles (MVs) by conventional flow cytometry is accomplished by the addition of a known amount of counting beads and calculated from the formula: MV/μl = (MV count/bead count) × final bead concentration. We sought to optimize each variable in the equation by determining the best parameters for detecting 'MV count' and examining the effects of different bead preparations and concentrations on the final calculation. Three commercially available bead preparations (TruCount, Flow-Count and CountBright) were tested, and MV detection on a BD FACSCanto was optimized for gating by either forward scatter (FSC) or side scatter (SSC); the results were compared by calculating different subsets of MV on a series of 74 typical patient plasma samples. The relationship between the number of beads added to each test and the number of beads counted by flow cytometry remained linear over a wide range of bead concentrations ( R 2 ≥ 0.997). However, TruCount beads produced the most consistent (concentration variation = 3.8%) calculated numbers of plasma CD41 + /Annexin V + MV, which were significantly higher from that calculated using either Flow-Count or CountBright ( p beads by FSC and 0.16 μm beads by SSC, but there were significantly more background events using SSC compared with FSC (3113 vs. 470; p = 0.008). In general, sample analysis by SSC resulted in significantly higher numbers of MV ( p beads provided linear results at concentrations ranging from 6 beads/μl to 100 beads/μl, but TruCount was the most consistent. Using SSC to gate MV events produced high background which negatively affected counting bead enumeration and overall MV calculations. Strategies to reduce SSC background should be employed in order to reliably use this technique.

  15. Calcium Pectinate Beads Formation: Shape and Size Analysis

    Directory of Open Access Journals (Sweden)

    Boon-Beng Lee

    2014-04-01

    Full Text Available The aim of this study was to investigate the inter-relationship between process variables and the size and shape of pectin solution droplets upon detachment from a dripping tip as well as Ca-pectinate beads formed after gelation via image analysis. The sphericity factor (SF of the droplets was generally smaller than 0.05. There was no specific trend between the SF of the droplets and the pectin concentration or the dripping tip radius. The SF the beads formed from high-concentration pectin solutions and a small dripping tip was smaller than 0.05. The results show that the Reynolds number and Ohnesorge number of the droplets fall within the operating region for forming spherical beads in the shape diagram, with the exception to the lower boundary. The lower boundary of the operating region has to be revised to Oh = 2.3. This is because the critical viscosity for Ca-pectinate bead formation is higher than that of Ca-alginate beads. On the other hand, the radius of the droplets and beads increased as the dripping tip radius increased. The bead radius can easily be predicted by Tate’s law equation.

  16. Bead-bead interaction parameters in dissipative particle dynamics: Relation to bead-size, solubility parameter, and surface tension

    Science.gov (United States)

    Maiti, Amitesh; McGrother, Simon

    2004-01-01

    Dissipative particle dynamics (DPD) is a mesoscale modeling method for simulating equilibrium and dynamical properties of polymers in solution. The basic idea has been around for several decades in the form of bead-spring models. A few years ago, Groot and Warren [J. Chem. Phys. 107, 4423 (1997)] established an important link between DPD and the Flory-Huggins χ-parameter theory for polymer solutions. We revisit the Groot-Warren theory and investigate the DPD interaction parameters as a function of bead size. In particular, we show a consistent scheme of computing the interfacial tension in a segregated binary mixture. Results for three systems chosen for illustration are in excellent agreement with experimental results. This opens the door for determining DPD interactions using interfacial tension as a fitting parameter.

  17. Simulation of non-linear coaxial line using ferrite beads

    International Nuclear Information System (INIS)

    Furuya, S.; Matsumoto, H.; Tachi, K.; Takano, S.; Irisawa, J.

    2002-01-01

    A ferrite sharpener is a non-linear coaxial line using ferrite beads, which produces high-voltage, high-dV/dt pulses. We have been examining the characteristics of ferrite sharpeners experimentally, varying various parameters. Also we have made the simulation of the ferrite sharpener and compared the predictions with the experimental results in detail to analyze the characteristics of the sharpener. In this report, calculating the magnetization M of the ferrite bead, we divide the bead into n sections radially instead of adopting M at the average radius in the previous report. (author)

  18. A High-Throughput SU-8Microfluidic Magnetic Bead Separator

    DEFF Research Database (Denmark)

    Bu, Minqiang; Christensen, T. B.; Smistrup, Kristian

    2007-01-01

    We present a novel microfluidic magnetic bead separator based on SU-8 fabrication technique for high through-put applications. The experimental results show that magnetic beads can be captured at an efficiency of 91 % and 54 % at flow rates of 1 mL/min and 4 mL/min, respectively. Integration...... of soft magnetic elements in the chip leads to a slightly higher capturing efficiency and a more uniform distribution of captured beads over the separation chamber than the system without soft magnetic elements....

  19. Drug-eluting versus plain balloon angioplasty for the treatment of failing dialysis access: Final results and cost-effectiveness analysis from a prospective randomized controlled trial (NCT01174472)

    Energy Technology Data Exchange (ETDEWEB)

    Kitrou, Panagiotis M., E-mail: panoskitrou@gmail.com [Department of Interventional Radiology, Patras University Hospital, School of Medicine, Rion 26504 (Greece); Katsanos, Konstantinos [Department of Interventional Radiology, Guy' s and St. Thomas’ Hospitals, NHS Foundation Trust, King' s Health Partners, London SE1 7EH (United Kingdom); Spiliopoulos, Stavros; Karnabatidis, Dimitris; Siablis, Dimitris [Department of Interventional Radiology, Patras University Hospital, School of Medicine, Rion 26504 (Greece)

    2015-03-15

    Highlights: •1-Year target lesion primary patency significantly higher after PCB application compared to plain balloon angioplasty in the failing dialysis access. •Significant difference in favor of PCB in cumulative primary patency of AVGs at 1 year. •No significant difference in cumulative primary patency of AVFs treated with PCB at 1 year. •Cost effectiveness analysis performed. •Paclitaxel-coated balloon angioplasty proves to be a cost-effective option for treating dialysis access. -- Abstract: Objective: To report the final results and cost-effectiveness analysis of a prospective randomized controlled trial investigating drug-eluting balloon (DEB) versus plain balloon angioplasty (BA) for the treatment of failing dialysis access ( (NCT01174472)). Methods: 40 patients were randomized to angioplasty with either DEB (n = 20) or BA (n = 20) for treatment of significant venous stenosis causing a failing dialysis access. Both arteriovenous fistulas (AVF) and synthetic arteriovenous grafts (AVG) were included. Angiographic follow up was scheduled every two months. Primary endpoints were technical success and target lesion primary patency at 1 year. Cumulative and survival analysis was performed. Incremental net benefit (INB) and incremental cost effectiveness ratio (ICER) were calculated and the cost-effectiveness acceptability curve (CEAC) was drawn. Results: Baseline variables were equally distributed between the two groups. At 1 year, cumulative target lesion primary patency was significantly higher after DEB application (35% vs. 5% after BA, p < 0.001). Overall, median primary patency was 0.64 years in case of DEB vs. 0.36 years in case of BA (p = 0.0007; unadjusted HR = 0.27 [95%CI: 0.13–0.58]; Cox adjusted HR = 0.23 [95%CI: 0.10–0.50]). ICER was 2198 Euros (€) per primary patency year of dialysis access gained. INB was 1068€ (95%CI: 31–2105€) for a willingness-to-pay (WTP) threshold of 5000€ (corresponding acceptability probability >97

  20. Capture, isolation and release of cancer cells with aptamer-functionalized glass bead array.

    Science.gov (United States)

    Wan, Yuan; Liu, Yaling; Allen, Peter B; Asghar, Waseem; Mahmood, M Arif Iftakher; Tan, Jifu; Duhon, Holli; Kim, Young-tae; Ellington, Andrew D; Iqbal, Samir M

    2012-11-21

    Early detection and isolation of circulating tumor cells (CTC) can enable better prognosis for cancer patients. A Hele-Shaw device with aptamer functionalized glass beads is designed, modeled, and fabricated to efficiently isolate cancer cells from a cellular mixture. The glass beads are functionalized with anti-epidermal growth factor receptor (EGFR) aptamer and sit in ordered array of pits in polydimethylsiloxane (PDMS) channel. A PDMS encapsulation is then used to cover the channel and to flow through cell solution. The beads capture cancer cells from flowing solution depicting high selectivity. The cell-bound glass beads are then re-suspended from the device surface followed by the release of 92% cells from glass beads using combination of soft shaking and anti-sense RNA. This approach ensures that the cells remain in native state and undisturbed during capture, isolation and elution for post-analysis. The use of highly selective anti-EGFR aptamer with the glass beads in an array and subsequent release of cells with antisense molecules provide multiple levels of binding and release opportunities that can help in defining new classes of CTC enumeration devices.

  1. Absorb bioresorbable vascular scaffold versus everolimus-eluting metallic stent in ST-segment elevation myocardial infarction: 1-year results of a propensity score matching comparison: the BVS-EXAMINATION Study (bioresorbable vascular scaffold-a clinical evaluation of everolimus eluting coronary stents in the treatment of patients with ST-segment elevation myocardial infarction).

    Science.gov (United States)

    Brugaletta, Salvatore; Gori, Tommaso; Low, Adrian F; Tousek, Petr; Pinar, Eduardo; Gomez-Lara, Josep; Scalone, Giancarla; Schulz, Eberhard; Chan, Mark Y; Kocka, Viktor; Hurtado, Jose; Gomez-Hospital, Juan Antoni; Münzel, Thomas; Lee, Chi-Hang; Cequier, Angel; Valdés, Mariano; Widimsky, Petr; Serruys, Patrick W; Sabaté, Manel

    2015-01-01

    The purpose of this study was to compare the 1-year outcome between bioresorbable vascular scaffold (BVS) and everolimus-eluting metallic stent (EES) in ST-segment elevation myocardial infarction (STEMI) patients. The Absorb BVS (Abbott Vascular, Santa Clara, California) is a polymeric scaffold approved for treatment of stable coronary lesions. Limited and not randomized data are available on its use in ST-segment elevation myocardial infarction (STEMI) patients. This study included 290 consecutive STEMI patients treated by BVS, compared with either 290 STEMI patients treated with EES or 290 STEMI patients treated with bare-metal stents (BMS) from the EXAMINATION (A Clinical Evaluation of Everolimus Eluting Coronary Stents in the Treatment of Patients With ST-segment Elevation Myocardial Infarction) trial, by applying propensity score matching. The primary endpoint was a device-oriented endpoint (DOCE), including cardiac death, target vessel myocardial infarction, and target lesion revascularization, at 1-year follow-up. Device thrombosis, according to the Academic Research Consortium criteria, was also evaluated. The cumulative incidence of DOCE did not differ between the BVS and EES or BMS groups either at 30 days (3.1% vs. 2.4%, hazard ratio [HR]: 1.31 [95% confidence interval (CI): 0.48 to 3.52], p = 0.593; vs. 2.8%, HR: 1.15 [95% CI: 0.44 to 2.30], p = 0.776, respectively) or at 1 year (4.1% vs. 4.1%, HR: 0.99 [95% CI: 0.23 to 4.32], p = 0.994; vs. 5.9%, HR: 0.50 [95% CI: 0.13 to 1.88], p = 0.306, respectively). Definite/probable BVS thrombosis rate was numerically higher either at 30 days (2.1% vs. 0.3%, p = 0.059; vs. 1.0%, p = 0.324, respectively) or at 1 year (2.4% vs. 1.4%, p = 0.948; vs. 1.7%, p = 0.825, respectively), as compared with EES or BMS. At 1-year follow-up, STEMI patients treated with BVS showed similar rates of DOCE compared with STEMI patients treated with EES or BMS, although rate of scaffolds thrombosis, mostly clustered in the early phase

  2. A planar conducting microstructure to guide and confine magnetic beads to a sensing zone

    KAUST Repository

    Gooneratne, Chinthaka Pasan

    2011-08-01

    A novel planar conducting microstructure is proposed to transport and confine magnetic micro/nano beads to a sensing zone. Manipulation and concentration of magnetic beads are achieved by employing square-shaped conducting micro-loops, with a few hundred nano-meters in thickness, arranged in a unique fashion. These microstructures are designed to produce high magnetic field gradients which are directly proportional to the force applied to manipulate the magnetic beads. Furthermore, the size of the microstructures allows greater maneuverability and control of magnetic beads than what could be achieved by permanent magnets. The aim of the microstructures is to guide magnetic beads from a large area and confine them to a smaller area where for example quantification would take place. Experiments were performed with different concentrations of 2 μm diameter magnetic beads. Experimental results showed that magnetic beads could be successfully guided and confined to the sensing zone. © 2011 Elsevier B.V. All rights reserved.

  3. On the occurrence of ‘bead lightning’ phenomena in long laboratory sparks

    Energy Technology Data Exchange (ETDEWEB)

    Vayanganie, S.P.A., E-mail: amilavayanganie@gmail.com [Atmospheric Physics and Lightning Research Group, University of Colombo, Colombo 03 (Sri Lanka); Cooray, V.; Rahman, Mahbubur; Hettiarachchi, Pasan; Diaz, Oscar [Lightning Research Group, The Ångström Laboratory Division of Electricity, Department of Engineering Sciences, Uppsala University, Box 534, SE-751 21 Uppsala (Sweden); Fernando, M. [Atmospheric Physics and Lightning Research Group, University of Colombo, Colombo 03 (Sri Lanka)

    2016-02-22

    The formation of bead lightning, where the lightning channel appears to break up into luminous fragments, is still an object of speculation. Here we report similar observations in laboratory discharges. Analysis of time resolved photographs shows that the discharge channel exhibits a ‘bead pattern’ in the decaying stage of the discharge and the occurrence of loops in the channel sections where the bead pattern is observed. This result presents the first evidence that the rapid cooling of non-uniform channel sections could lead to the formation of beads. It is suggested that periodically occurring non-uniform channel sections could explain the bead pattern of lightning discharges. - Highlights: • For the first time, the occurrence of bead patterns in the channel of laboratory sparks was reported. • Depending on the geometry some regions of the channel decays faster than the other sections. • A possible mechanism for the occurrence of beads in decaying states of lightning flashes is proposed.

  4. Biosorption of americium by alginate beads

    International Nuclear Information System (INIS)

    Borba, Tania Regina de; Marumo, Julio Takehiro; Goes, Marcos Maciel de; Ferreira, Rafael Vicente de Padua; Sakata, Solange Kazumi

    2009-01-01

    The use of biotechnology to remove heavy metals from wastes plays great potential in treatment of radioactive wastes and therefore the aim of this study was to evaluate the biosorption of americium by alginate beads. Biosorption has been defined as the property of certain biomolecules to bind and remove selected ions or other molecules from aqueous solutions. The calcium alginate beads as biosorbent were prepared and analyzed for americium uptaking. The experiments were performed in different solution activity concentrations, pH and exposure time. The results suggest that biosorption process is more efficient at pH 4 and for 75, 150, 300 Bq/mL and 120 minutes were necessary to remove almost 100% of the americium-241 from the solution. (author)

  5. Influence of recycled polystyrene beads on cement paste properties

    Directory of Open Access Journals (Sweden)

    Maaroufi Maroua

    2018-01-01

    Full Text Available In order to keep up with the requirements of sustainable development, there is a growing interest towards reducing the energy consumption in the construction and rehabilitation of buildings and the promotion of recycling waste in building materials. The use of recycled polystyrene beads in cement-based materials composition constitutes a solution to improve the insulation in buildings. This allows also limiting landfill by reusing the polystyrene waste. The aim of this study is to compare some properties and performances of a cement paste containing polystyrene beads to a reference paste designed with only the same cement. An experimental campaign was conducted and the obtained results showed that adding recycled polystyrene beads to a cement paste improves its hygro-thermal properties. Further studies are however necessary to better understand the real role of the polystyrene beads in the heat and mass transfers.

  6. Elution behavior of heavy metals from cement solidified products of incinerated ash waste - 59102

    International Nuclear Information System (INIS)

    Meguro, Yoshihiro; Kawato, Yoshimi; Nakayama, Takuya; Tomioka, Osamu; Mitsuda, Motoyuki

    2012-01-01

    A method, in which incinerated ash is solidified with a cement material, has been developed to dispose radioactive incinerated ash waste. In order to bury the solidified product, it is required that elution of hazardous heavy metals included in the ash from the solidified products is inhibited. In this study, the elution behavior of the heavy metals from the synthetic solidified products, which included Pb(II), Cd(II), and Cr(VI) and were prepared using ordinary portland cement (OPC), blast furnace slag cement (BFS), or a cement material that showed low alkalinity (LA-Cement), was investigated. Several chemicals and materials were added as additive agents to prevent the elution of the heavy metals. When OPC was used, Cd elution was inhibited, but Pb and Cr were not enough even using the additive agent examined. FeSO 4 and Na 2 S additive agents worked effective to inhibit elution of Cr. When BFS was used, the elution of Pb, Cd and Cr was inhibited for the all products prepared. In the case of LA-Cement, the elution of Pb and Cd was inhibited for the all products, but only the product that was added FeSO 4 showed good result of the elution of Cr. (authors)

  7. Antibiotic-Loaded Synthetic Calcium Sulfate Beads for Prevention of Bacterial Colonization and Biofilm Formation in Periprosthetic Infections

    Science.gov (United States)

    Howlin, R. P.; Brayford, M. J.; Webb, J. S.; Cooper, J. J.; Aiken, S. S.

    2014-01-01

    Periprosthetic infection (PI) causes significant morbidity and mortality after fixation and joint arthroplasty and has been extensively linked to the formation of bacterial biofilms. Poly(methyl methacrylate) (PMMA), as a cement or as beads, is commonly used for antibiotic release to the site of infection but displays variable elution kinetics and also represents a potential nidus for infection, therefore requiring surgical removal once antibiotics have eluted. Absorbable cements have shown improved elution of a wider range of antibiotics and, crucially, complete biodegradation, but limited data exist as to their antimicrobial and antibiofilm efficacy. Synthetic calcium sulfate beads loaded with tobramycin, vancomycin, or vancomycin-tobramycin dual treatment (in a 1:0.24 [wt/wt] ratio) were assessed for their abilities to eradicate planktonic methicillin-resistant Staphylococcus aureus (MRSA) and Staphylococcus epidermidis relative to that of PMMA beads. The ability of the calcium sulfate beads to prevent biofilm formation over multiple days and to eradicate preformed biofilms was studied using a combination of viable cell counts, confocal microscopy, and scanning electron microscopy of the bead surface. Biofilm bacteria displayed a greater tolerance to the antibiotics than their planktonic counterparts. Antibiotic-loaded beads were able to kill planktonic cultures of 106 CFU/ml, prevent bacterial colonization, and significantly reduce biofilm formation over multiple days. However, established biofilms were harder to eradicate. These data further demonstrate the difficulty in clearing established biofilms; therefore, early preventive measures are key to reducing the risk of PI. Synthetic calcium sulfate loaded with antibiotics has the potential to reduce or eliminate biofilm formation on adjacent periprosthetic tissue and prosthesis material and, thus, to reduce the rates of periprosthetic infection. PMID:25313221

  8. Selective elution of HLA antigens and beta 2-microglobulin from human platelets by chloroquine diphosphate

    International Nuclear Information System (INIS)

    Kao, K.J.

    1988-01-01

    To determine whether chloroquine can specifically elute HLA antigens and beta 2-microglobulin (beta 2-M) from the platelet surface, quantitative immunofluorescence flow cytometry and monoclonal antibodies were used to show that HLA antigens and beta 2-M were proportionally eluted from the platelet surface without affecting the membrane glycoproteins IIb and IIIa. Second, an autoradiogram of electrophoresed I-125-labeled platelets showed that only beta 2-M but not other I-125-labeled membrane proteins could be eluted. Although HLA antigens were poorly labeled by I-125 and could not be detected on the autoradiogram, the eluted HLA antigens could be detected by anti-HLA monoclonal antibody and immunoblotting techniques. No loss of plasma membrane integrity was observed by transmission electron microscopy after chloroquine treatment of platelets. The results indicate that chloroquine selectively elutes HLA antigens and their noncovalently associated beta 2-M without affecting other integral platelet membrane proteins

  9. Long-Term Safety of Drug-Eluting and Bare-Metal Stents

    DEFF Research Database (Denmark)

    Palmerini, Tullio; Benedetto, Umberto; Biondi-Zoccai, Giuseppe

    2015-01-01

    BACKGROUND: Previous meta-analyses have investigated the relative safety and efficacy profiles of different types of drug-eluting stents (DES) and bare-metal stents (BMS); however, most prior trials in these meta-analyses reported follow-up to only 1 year, and as such, the relative long-term safety....... RESULTS: Fifty-one trials that included a total of 52,158 randomized patients with follow-up duration ≥3 years were analyzed. At a median follow-up of 3.8 years, cobalt-chromium everolimus-eluting stents (EES) were associated with lower rates of mortality, definite stent thrombosis (ST), and myocardial...... infarction than BMS, paclitaxel-eluting stents (PES), and sirolimus-eluting stents (SES) and less ST than BES. Phosphorylcholine-based zotarolimus-eluting stents had lower rates of definite ST than SES and lower rates of myocardial infarction than BMS and PES. The late rates of target...

  10. Plasma membrane isolation using immobilized concanavalin A magnetic beads.

    Science.gov (United States)

    Lee, Yu-Chen; Srajer Gajdosik, Martina; Josic, Djuro; Lin, Sue-Hwa

    2012-01-01

    Isolation of highly purified plasma membranes is the key step in constructing the plasma membrane proteome. Traditional plasma membrane isolation method takes advantage of the differential density of organelles. While differential centrifugation methods are sufficient to enrich for plasma membranes, the procedure is lengthy and results in low recovery of the membrane fraction. Importantly, there is significant contamination of the plasma membranes with other organelles. The traditional agarose affinity matrix is suitable for isolating proteins but has limitation in separating organelles due to the density of agarose. Immobilization of affinity ligands to magnetic beads allows separation of affinity matrix from organelles through magnets and could be developed for the isolation of organelles. We have developed a simple method for isolating plasma membranes using lectin concanavalin A (ConA) magnetic beads. ConA is immobilized onto magnetic beads by binding biotinylated ConA to streptavidin magnetic beads. The ConA magnetic beads are used to bind glycosylated proteins present in the membranes. The bound membranes are solubilized from the magnetic beads with a detergent containing the competing sugar alpha methyl mannoside. In this study, we describe the procedure of isolating rat liver plasma membranes using sucrose density gradient centrifugation as described by Neville. We then further purify the membrane fraction by using ConA magnetic beads. After this purification step, main liver plasma membrane proteins, especially the highly glycosylated ones and proteins containing transmembrane domains could be identified by LC-ESI-MS/MS. While not described here, the magnetic bead method can also be used to isolate plasma membranes from cell lysates. This membrane purification method should expedite the cataloging of plasma membrane proteome.

  11. Static antibiotic spacers augmented by calcium sulphate impregnated beads in revision TKA: Surgical technique and review of literature.

    Science.gov (United States)

    Risitano, Salvatore; Sabatini, Luigi; Atzori, Francesco; Massè, Alessandro; Indelli, Pier Francesco

    2018-06-01

    Periprosthetic joint infection (PJI) is a serious complication in total knee arthroplasty (TKA) and represents one of the most common causes of revision. The challenge for surgeons treating an infected TKA is to quickly obtain an infection-free joint in order to re-implant, when possible, a new TKA. Recent literature confirms the role of local antibiotic-loaded beads as a strong bactericidal, allowing higher antibiotic elution when compared with antibiotic loaded spacers only. Unfortunately, classical Polymethylmethacrylate (PMMA) beads might allow bacteria adhesion, secondary development of antibiotic resistance and eventually surgical removal once antibiotics have eluted. This article describes a novel surgical technique using static, custom-made antibiotic loaded spacers augmented by calcium sulphate antibiotic-impregnated beads to improve the success rate of revision TKA in a setting of PJI. The use of calcium sulphate beads has several potential benefits, including a longer sustained local antibiotic release when compared with classical PMMA beads and, being resorbable, not requiring accessory surgical interventions.

  12. Hydrodynamic Torques and Rotations of Superparamagnetic Bead Dimers

    Science.gov (United States)

    Pease, Christopher; Etheridge, J.; Wijesinghe, H. S.; Pierce, C. J.; Prikockis, M. V.; Sooryakumar, R.

    Chains of micro-magnetic particles are often rotated with external magnetic fields for many lab-on-a-chip technologies such as transporting beads or mixing fluids. These applications benefit from faster responses of the actuated particles. In a rotating magnetic field, the magnetization of superparamagnetic beads, created from embedded magnetic nano-particles within a polymer matrix, is largely characterized by induced dipoles mip along the direction of the field. In addition there is often a weak dipole mop that orients out-of-phase with the external rotating field. On a two-bead dimer, the simplest chain of beads, mop contributes a torque Γm in addition to the torque from mip. For dimers with beads unbound to each other, mop rotates individual beads which generate an additional hydrodynamic torque on the dimer. Whereas, mop directly torques bound dimers. Our results show that Γm significantly alters the average frequency-dependent dimer rotation rate for both bound and unbound monomers and, when mop exceeds a critical value, increases the maximum dimer rotation frequency. Models that include magnetic and hydrodynamics torques provide good agreement with the experimental findings over a range of field frequencies.

  13. Intimal hyperplasia and vascular remodeling after everolimus-eluting and sirolimus-eluting stent implantation in diabetic patients the randomized diabetes and drug-eluting stent (DiabeDES) IV intravascular ultrasound trial

    DEFF Research Database (Denmark)

    Antonsen, Lisbeth; Maeng, Michael; Thayssen, Per

    2013-01-01

    OBJECTIVE: To evaluate the effects of the everolimus-eluting Xience™/Promus™ stent (EES) and the sirolimus-eluting Cypher™ stent (SES) on intimal hyperplasia (IH) in diabetic patients. BACKGROUND: Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent...... implantation due to intimal hyperplasia (IH). METHODS: In a sub study of the Randomized Comparison of Everolimus-Eluting and Sirolimus-Eluting Stents in Patients Treated with Percutaneous Coronary Intervention (SORT OUT IV trial), serial intravascular ultrasound (IVUS) 10-month follow-up data were available...... in 88 patients, including 48 EES and 40 SES treated patients. IVUS endpoints included IH volume, in-stent % volume obstruction and changes in external elastic membrane (EEM) volume. RESULTS: Compared with the SES group, IH volume was increased in the EES group [median (interquartile range): 2.8 mm(3) (0...

  14. Calibration beads containing luminescent lanthanide ion complexes

    Science.gov (United States)

    The reliability of lanthanide luminescence measurements, by both flow cytometry and digital microscopy, will be enhanced by the availability of narrow-band emitting lanthanide calibration beads. These beads can also be used to characterize spectrographic instruments, including mi...

  15. Economic Outcomes of Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Stents in Patients Undergoing Percutaneous Coronary Intervention: 1-Year Results From the ABSORB III Trial.

    Science.gov (United States)

    Baron, Suzanne J; Lei, Yang; Chinnakondepalli, Khaja; Vilain, Katherine; Magnuson, Elizabeth A; Kereiakes, Dean J; Ellis, Stephen G; Stone, Gregg W; Cohen, David J

    2017-04-24

    The purpose of this study was to evaluate the economic impact of the Absorb bioresorbable vascular scaffold compared with the Xience everolimus-eluting stent in patients undergoing percutaneous coronary intervention. The ABSORB III trial (Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease) demonstrated that the Absorb scaffold was noninferior to the Xience stent with respect to target lesion failure at 1 year. Whether health care costs differ between the Absorb scaffold and the Xience stent is unknown. We performed a prospective health economic study alongside the ABSORB III trial, in which patients undergoing percutaneous coronary intervention for stable or unstable angina were randomized to receive the Absorb scaffold (n = 1,322) or Xience stent (n = 686). Resource use data were collected through 1 year of follow-up. Costs were assessed using resource-based accounting (for procedures), MedPAR data (for other index hospitalization costs), and Medicare reimbursements (for follow-up costs and physician fees). Initial procedural costs were higher with the Absorb scaffold than the Xience stent ($6,316 ± 1,892 vs. $6,103 ± 1,895; p = 0.02), driven mainly by greater balloon catheter use and the higher cost of the scaffold in the Absorb group. Nonetheless, index hospitalization costs ($15,035 ± 2,992 for Absorb vs. $14,903 ± 3,449 for Xience; p = 0.37) and total 1-year costs ($17,848 ± 6,110 for Absorb vs. $17,498 ± 7,411 for Xience; p = 0.29) were similar between the 2 groups. Although initial procedural costs were higher with the Absorb scaffold, there were no differences in total 1-year health care costs between the 2 cohorts. Longer term follow-up is needed to determine whether meaningful cost savings emerge after scaffold resorption. (A Clinical Evaluation of Absorb™ BVS, the Everolimus-Eluting Bioresorbable Vascular Scaffold in the Treatment of Subjects With de Novo Native Coronary Artery Lesions; NCT01751906). Copyright © 2017

  16. Neutron activation analysis of AD 1660-1930 European copper-coloured blue glass trade beads from Ontario, Canada

    International Nuclear Information System (INIS)

    Kenyon, I.; Hancock, R.G.V.; Aufreiter, S.

    1995-01-01

    Blue glass trade beads from well-dated late seventeenth- to early twentieth-century sites and collections have been analysed non-destructively by instrumental neutron activation analysis. The beads display enough variations in their elemental contents to allow us to characterize the different chemistries. The implication of these results is that similar chemical analyses of blue beads from undated archaeological sites may be used to help date the sites, since each bead chemistry has a specific earliest period. (author)

  17. Preparation of Macroporous Poly (vinyl alcohol-co-triallyl isocyanurate) Beads Bearing Aminocarboxylic Acid as Functional Groups by Suspension Polymerization

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    Macroporous poly (vinyl acetate-co-triallyl isocyanurate) beads were prepared with suspension polymerization method. The copolymer beads were then transformed into poly (vinyl alcohol-co-triallyl isocyanurate) by ester exchange reaction. Aminocarboxylic acids were immobilized on the copolymer beads by the esterification of hydroxyl groups with diethyl-lenetriaminepentaacetic bisanhydride. The weak acid exchange capacities, specific surface areas and mean pore diameters of the resultant resin beads were measured.

  18. Effects of agitation rate on aggregation during beads-to-beads subcultivation of microcarrier culture of human mesenchymal stem cells.

    Science.gov (United States)

    Takahashi, Iori; Sato, Keigo; Mera, Hisashi; Wakitani, Shigeyuki; Takagi, Mutsumi

    2017-06-01

    With the aim to utilize human mesenchymal stem cells (hMSCs) grown in large scale for regenerative medicine, effects of agitation rate on aggregation during beads-to-beads subcultivation of microcarrier culture of hMSCs were studied. hMSCs could attach and grew on surface-type microcarriers of Cytodex 1, whereas almost no cell elongation and growth were observed on porous type microcarriers of Cytopores. The percentages of aggregated Cytodex 1 microcarriers at an agitation rate of 60 and 90 rpm were lower than that at 30 rpm, which was the lowest agitation rate necessary for the suspension of Cytodex 1 microcarriers, and the cells grew fastest at 60 rpm. hMSC could be subcultivated on Cytodex 1 by the beads-to-beads method at both 30 and 60 rpm without trypsinization. However, agitation at 60 rpm resulted in a markedly lower percentage of aggregated microcarriers not only before but also after subcultivation. The percentages of CD90- and CD166-positive cells among cells grown on Cytodex 1 at 60 rpm (91.5 and 87.6 %) were comparable to those of cells grown in the pre-culture on dishes. In conclusion, hMSCs could be subcultivated on Cytodex 1 by beads-to-beads method maintaining the expressions of the cell surface antigens CD90 and CD166, while adjusting agitation rate could decrease the microcarrier aggregation.

  19. Sustained release of bactericidal concentrations of penicillin in the pleural space via an antibiotic-eluting pigtail catheter coated with electrospun nanofibers: results from in vivo and in vitro studies.

    Science.gov (United States)

    Chao, Yin-Kai; Lee, Cheng-Hung; Liu, Kuo-Sheng; Wang, Yi-Chuan; Wang, Chih-Wei; Liu, Shih-Jung

    2015-01-01

    Inadequate intrapleural drug concentrations caused by poor penetration of systemic antibiotics into the pleural cavity is a major cause of treatment failure in empyema. Herein, we describe a novel antibiotic-eluting pigtail catheter coated with electrospun nanofibers used for the sustained release of bactericidal concentrations of penicillin in the pleural space. Electrospun nanofibers prepared using polylactide-polyglycolide copolymer and penicillin G sodium dissolved in 1,1,1,3,3,3-hexafluoro-2-propanol were used to coat the surface of an Fr6 pigtail catheter. The in vitro patterns of drug release were tested by placing the catheter in phosphate-buffered saline. In vivo studies were performed using rabbits treated with penicillin either intrapleurally (Group 1, 20 mg delivered through the catheter) or systemically (Group 2, intramuscular injection, 10 mg/kg). Penicillin concentrations in the serum and pleural fluid were then measured and compared. In vitro studies revealed a burst release of penicillin (10% of the total dose) occurring in the first 24 hours, followed by a sustained release in the subsequent 30 days. Intrapleural drug levels were significantly higher in Group 1 than in Group 2 (Ppenicillin concentrations remained above the minimum inhibitory concentration breakpoint throughout the entire study period. In contrast, serum penicillin levels were significantly higher in Group 2 than in Group 1 (P<0.001). Notably, all Group 2 rabbits showed signs of systemic toxicity (paralytic ileus and weight loss). We conclude that our antibiotic-eluting catheter may serve as a novel therapeutic option to treat empyema.

  20. Efficacy and Safety of the Absorb Everolimus-Eluting Bioresorbable Scaffold for Treatment of Patients With Diabetes Mellitus: Results of the Absorb Diabetic Substudy.

    Science.gov (United States)

    Kereiakes, Dean J; Ellis, Stephen G; Kimura, Takeshi; Abizaid, Alexandre; Zhao, Weiying; Veldhof, Susan; Vu, Minh-Thien; Zhang, Zhen; Onuma, Yoshinobu; Chevalier, Bernard; Serruys, Patrick W; Stone, Gregg W

    2017-01-09

    The study sought to evaluate the efficacy and safety of the Absorb everolimus-eluting bioresorbable vascular scaffold (BVS) (Abbott Vascular, Abbott Park, Illinois) in patients with diabetes mellitus. Randomized, controlled trials have demonstrated comparable clinical outcomes following percutaneous coronary intervention with either Absorb BVS or metallic Xience everolimus-eluting stent. However, these trials lack power required to provide reliable treatment effect estimates in this high-risk population. In a pre-specified, powered analysis, patients with diabetes who received ≥1 Absorb were pooled from the ABSORB II, III, and JAPAN randomized trials and from the single arm ABSORB EXTEND registry. The study composite primary endpoint was target lesion failure (TLF) at 1 year following Absorb BVS compared with a performance goal of 12.7%. Among 754 diabetic patients included in analysis (27.3% insulin treated), the 1-year TLF rate was 8.3% (upper 1-sided 95% confidence limit: 10.1%; p = 0.0001 vs. performance goal). Scaffold thrombosis (definite or probable) was observed in 2.3% of patients. Multivariable regression identified older age, insulin treatment, and smaller pre-procedure reference vessel diameter as significant independent predictors of 1-year TLF. The Absorb diabetic substudy suggests efficacy and safety of the Absorb BVS for treatment of patients with diabetes mellitus. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  1. Preparation and characterization of chitosan/cashew gum beads loaded with Lippia sidoides essential oil

    Energy Technology Data Exchange (ETDEWEB)

    Paula, Haroldo C.B., E-mail: hpaula@ufc.br [Department of Analytical and Physical Chemistry, Federal University of Ceara, UFC, Fortaleza-CE (Brazil); Sombra, Fernanda Matoso; Cavalcante, Rafaela de Freitas; Abreu, Flavia O.M.S. [Department of Analytical and Physical Chemistry, Federal University of Ceara, UFC, Fortaleza-CE (Brazil); Paula, Regina C.M. de [Department of Organic and Inorganic Chemistry, Federal University of Ceara, UFC, Fortaleza-CE (Brazil)

    2011-03-12

    Beads based on chitosan (CH) and cashew gum (CG), were prepared and loaded with an essential oil with larvicide activity (Lippia sidoides - Ls). CH and CH-CG beads were characterized by scanning electron microscopy (SEM), infrared and UV-VIS spectroscopy, thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC), as well as, regarding their larvicide loading, swelling, in vitro and in vivo release kinetics. The oil encapsulation was evidenced by FTIR analysis and LS loading ranges from 2.4% to 4.4%. CH beads duly showed swelling degree (Q) values from 4.0 to 6.7, reaching equilibrium after 30 min, whereas crosslinked CH-CG beads showed lower swelling values, from 0.4 to 3.8, exhibiting a longer equilibrium time. Liquid transport parameters have revealed diffusion coefficient for CH-CG beads, as low as 2 x 10{sup -15} m{sup 2}/s. TGA and DSC revealed that CH:CG crosslinked beads are more thermally stable than CH beads. In vitro release follows a non-Fickian diffusion profile for both bead types, however, and a prolonged release being achieved only after beads crosslinking. In vivo release showed that both CH and CH-CG presented a prolonged larvicide effect. These aforesaid results, indicate that CH-CG beads loaded with LS are efficient for A. aegypti larval control.

  2. Preparation and characterization of chitosan/cashew gum beads loaded with Lippia sidoides essential oil

    International Nuclear Information System (INIS)

    Paula, Haroldo C.B.; Sombra, Fernanda Matoso; Cavalcante, Rafaela de Freitas; Abreu, Flavia O.M.S.; Paula, Regina C.M. de

    2011-01-01

    Beads based on chitosan (CH) and cashew gum (CG), were prepared and loaded with an essential oil with larvicide activity (Lippia sidoides - Ls). CH and CH-CG beads were characterized by scanning electron microscopy (SEM), infrared and UV-VIS spectroscopy, thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC), as well as, regarding their larvicide loading, swelling, in vitro and in vivo release kinetics. The oil encapsulation was evidenced by FTIR analysis and LS loading ranges from 2.4% to 4.4%. CH beads duly showed swelling degree (Q) values from 4.0 to 6.7, reaching equilibrium after 30 min, whereas crosslinked CH-CG beads showed lower swelling values, from 0.4 to 3.8, exhibiting a longer equilibrium time. Liquid transport parameters have revealed diffusion coefficient for CH-CG beads, as low as 2 x 10 -15 m 2 /s. TGA and DSC revealed that CH:CG crosslinked beads are more thermally stable than CH beads. In vitro release follows a non-Fickian diffusion profile for both bead types, however, and a prolonged release being achieved only after beads crosslinking. In vivo release showed that both CH and CH-CG presented a prolonged larvicide effect. These aforesaid results, indicate that CH-CG beads loaded with LS are efficient for A. aegypti larval control.

  3. Elution behavior of poly(ethylene glycol) through poly(vinyl alcohol) gel column using several solvents as eluents

    International Nuclear Information System (INIS)

    Hirayama, Chuichi; Motozato, Yoshiaki; Matsumoto, Kazuaki.

    1983-01-01

    γ-Irradiated poly(vinyl alcohol) beads, which were sufficiently allowed to swell in water, were washed with methanol, and then were packed into column. Gel chromatography was performed using methanol, benzene, esters and ketones as eluents and poly(ethylene glycol) as a sample. When the elution was carried out using methanol and benzene as eluents, elution behavior of samples was ordinary. When ethyl formate, methyl acetate and ethyl propionate were used as eluents, samples were slightly adsorbed and the elution was delayed. In the case the elution was carried out using ethyl acetate, propyl acetate, butyl acetate and ethyl methyl ketone as eluents, samples were adsorbed strongly on the bed material, and the adsorption curve was analogous to the calibration curve using methanol as an eluent. Dried poly(vinyl alcohol) gel as a packing material, showed ordinary elution behaviors for the samples. The adsorption of poly(ethylene glycol) on the present bed material was attributed to the existence of hydrated water on poly(vinyl alcohol) gel matrix. (author)

  4. Evaluation of electrochemical ion exchange for cesium elution

    International Nuclear Information System (INIS)

    Bontha, J.D.; Kurath, D.E.; Surma, J.E.; Buehler, M.F.

    1996-04-01

    Electrochemical elution was investigated as an alternative method to acid elution for the desorption of cesium from loaded ion exchange resins. The approach was found to have several potential advantages over existing technologies, in particular, electrochemical elution eliminates the need for addition of chemicals to elute cesium from the ion exchange resin. Also, since, in the electrochemical elution process the eluting solution is not in direct contact with the ion exchange material, very small volumes of the eluting solution can be used in a complete recycle mode in order to minimize the total volume of the cesium elute. In addition, the cesium is eluted as an alkaline solution that does not require neutralization with caustic to meet the tank farm specifications. Other advantages include easy incorporation of the electrochemical elution process into the present cesium recovery schemes

  5. Microstructural Study on Oxygen Permeated Arc Beads

    Directory of Open Access Journals (Sweden)

    Kuan-Heng Liu

    2015-01-01

    Full Text Available We simulated short circuit of loaded copper wire at ambient atmosphere and successfully identified various phases of the arc bead. A cuprous oxide flake was formed on the surface of the arc bead in the rapid solidification process, and there were two microstructural constituents, namely, Cu-κ eutectic structure and solutal dendrites. Due to the arc bead formed at atmosphere during the local equilibrium solidification process, the phase of arc bead has segregated to the cuprous oxide flake, Cu-κ eutectic, and Cu phase solutal dendrites, which are the fingerprints of the arc bead permeated by oxygen.

  6. Magnetic bead detection using nano-transformers

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung Kwon; Ahn, Doyeol [Institute of Quantum Information Processing and Systems, University of Seoul, 90 Jeonnong, Dongdaemun, Seoul 130-743 (Korea, Republic of); Hwang, Jong Seung; Hwang, Sung Woo, E-mail: dahn@uos.ac.kr [Research Center for Time-domain Nano-functional Devices and School of Electrical Engineering, Korea University, 5-1 Anam, Sungbuk, Seoul 136-701 (Korea, Republic of)

    2010-11-19

    A novel scheme to detect magnetic beads using a nano-scale transformer with a femtoweber resolution is reported. We have performed a Faraday's induction experiment with the nano-transformer at room temperature. The transformer shows the linear output voltage responses to the sinusoidal input current. When magnetic beads are placed on the transformer, the output responses are increased by an amount corresponding to the added magnetic flux from the beads when compared with the case of no beads on the transformer. In this way, we could determine whether magnetic beads are on top of the transformer in a single particle level.

  7. Magnetic bead detection using nano-transformers.

    Science.gov (United States)

    Kim, Hyung Kwon; Hwang, Jong Seung; Hwang, Sung Woo; Ahn, Doyeol

    2010-11-19

    A novel scheme to detect magnetic beads using a nano-scale transformer with a femtoweber resolution is reported. We have performed a Faraday's induction experiment with the nano-transformer at room temperature. The transformer shows the linear output voltage responses to the sinusoidal input current. When magnetic beads are placed on the transformer, the output responses are increased by an amount corresponding to the added magnetic flux from the beads when compared with the case of no beads on the transformer. In this way, we could determine whether magnetic beads are on top of the transformer in a single particle level.

  8. Zotarolimus-eluting vs. sirolimus-eluting coronary stents in patients with and without acute coronary syndromes

    DEFF Research Database (Denmark)

    Thim, Troels; Maeng, Michael; Kaltoft, Anne Kjer

    2012-01-01

    To compare clinical outcomes among patients with acute coronary syndrome treated with zotarolimus-eluting and sirolimus-eluting stents in the SORT OUT III trial.......To compare clinical outcomes among patients with acute coronary syndrome treated with zotarolimus-eluting and sirolimus-eluting stents in the SORT OUT III trial....

  9. XIENCE V everolimus-eluting coronary stent system: a novel second generation drug-eluting stent

    NARCIS (Netherlands)

    Beijk, Marcel A. M.; Piek, Jon J.

    2007-01-01

    Drug-eluting stents (DES) have been shown to be safe and significantly reduce clinical events and angiographic restenosis in the percutaneous treatment of coronary artery disease. Currently, three DES have been approved in Europe and Northern America: the sirolimus-eluting stent (SES), the

  10. Direct friction measurement in draw bead testing

    DEFF Research Database (Denmark)

    Olsson, David Dam; Bay, Niels; Andreasen, Jan Lasson

    2005-01-01

    The application of draw beads in sheet metal stamping ensures controlled drawing-in of flange parts. Lubrication conditions in draw beads are severe due to sliding under simultaneous bending. Based on the original draw bead test design by Nine [1] comprehensive studies of friction in draw beads...... have been reported in literature. A major drawback in all these studies is that friction is not directly measured, but requires repeated measurements of the drawing force with and without relative sliding between the draw beads and the sheet material. This implies two tests with a fixed draw bead tool...... and a freely rotating tool respectively, an approach, which inevitably implies large uncertainties due to scatter in the experimental conditions. In order to avoid this problem a new draw bead test is proposed by the authors measuring the friction force acting on the tool radius directly by a build...

  11. Modeling of welded bead profile for rapid prototyping by robotic MAG welding

    Institute of Scientific and Technical Information of China (English)

    CAO Yong; ZHU Sheng; WANG Tao; WANG Wanglong

    2009-01-01

    As a deposition technology, robotic metal active gas(MAG) welding has shown new promise for rapid prototyping (RP) of metallic parts. During the process of metal forming using robotic MAG welding, sectional profile of single-pass welded bead is critical to formed accuracy and quality of metal pans. In this paper, the experiments of single-pass welded bead for rapid prototyping using robotic MAG welding were carried out. The effect of some edge detectors on the cross-sectional edge of welded bead was discussed and curve fitting was applied using leat square fitting. Consequently, the mathematical model of welded bead profile was developed. The experimental results show that good shape could be obtained under suitable welding parameters. Canny operawr is suitable to edge detection of welded bead profile, and the mathematical model of welded bead profile developed is approximately parabola.

  12. Magnetic measurements of suspended functionalised ferromagnetic beads under DC applied fields

    International Nuclear Information System (INIS)

    De Los Santos V, Luis; Llandro, Justin; Lee, Dongwook; Mitrelias, Thanos; Palfreyman, Justin J.; Hayward, Thomas J.; Cooper, Jos; Bland, J.A.C.; Barnes, Crispin H.W.; Arroyo C, Juan L.; Lees, Martin

    2009-01-01

    In this work, a simple technique to obtain the hysteresis loops of magnetic beads (Spherotech Inc.) in liquid suspension is presented. The magnetic measurements were taken in a DC Magnetic Property Measurement System (MPMS-SQUID sensor). Samples were based on ferromagnetic beads (surface-functionalized NH 2 , mean diameter 4.32 μm) prepared in three conditions: dry, suspended in sucrose solution and in suspension after functionalization with fluorophore. Special small containers (1.3 cm long) made of non magnetic plastic were designed to hold the beads in liquid. The results indicate that the bead's remnant magnetization is half of the value at maximum applied field in all cases. However, due to the additional degrees of rotational freedom, beads suspended in a liquid do not present coercivity. The use of ferromagnetic beads and magnetic elements of different architectures for applications in bioassays is also discussed.

  13. Towards enhanced automated elution systems for waterborne protozoa using megasonic energy.

    Science.gov (United States)

    Horton, B; Katzer, F; Desmulliez, M P Y; Bridle, H L

    2018-02-01

    Continuous and reliable monitoring of water sources for human consumption is imperative for public health. For protozoa, which cannot be multiplied efficiently in laboratory settings, concentration and recovery steps are key to a successful detection procedure. Recently, the use of megasonic energy was demonstrated to recover Cryptosporidium from commonly used water industry filtration procedures, forming thereby a basis for a simplified and cost effective method of elution of pathogens. In this article, we report the benefits of incorporating megasonic sonication into the current methodologies of Giardia duodenalis elution from an internationally approved filtration and elution system used within the water industry, the Filta-Max®. Megasonic energy assisted elution has many benefits over current methods since a smaller final volume of eluent allows removal of time-consuming centrifugation steps and reduces manual involvement resulting in a potentially more consistent and more cost-effective method. We also show that megasonic sonication of G. duodenalis cysts provides the option of a less damaging elution method compared to the standard Filta-Max® operation, although the elution from filter matrices is not currently fully optimised. A notable decrease in recovery of damaged cysts was observed in megasonic processed samples, potentially increasing the abilities of further genetic identification options upon isolation of the parasite from a filter sample. This work paves the way for the development of a fully automated and more cost-effective elution method of Giardia from water samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. An optimized method for elution of enteroviral RNA from a cellulose-based substrate.

    Science.gov (United States)

    Li, Yan; Yoshida, Hiromu; Wang, Lu; Tao, Zexin; Wang, Haiyan; Lin, Xiaojuan; Xu, Aiqiang

    2012-12-01

    The Flinders Technology Australia (FTA) Elute Card is a commercial product that facilitates the collection, transport, archiving and processing of nucleic acids from a wide variety of biological samples at room temperature. While the cards have been designed so that sterile/deionized water can elute DNA easily, they are not suitable for some less stable RNAs. This study was undertaken to determine the optimal conditions such as the buffer type, buffer pH and incubation temperature for the elution of enteroviral RNA from FTA Elute Cards prior to quantitative analysis using real-time PCR (qPCR) or consensus degenerate hybrid oligonucleotide primer VP1 RT-semi nested PCR (CODEHOP VP1 RT-snPCR). TE-1 (pH 8.0), rather than sterile water, was the best buffer for high efficiency elution of enteroviral RNA at 95°C. However, as the estimated recovery rate of viral RNA eluted from the cards averaged to be only 6.1%, enterovirus assays using FTA elution should be considered qualitative, especially at low virus titers, and therefore the results of the assay should be interpreted carefully. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. EVALUATION OF PETROLEUM HYDROCARBONS ELUTION FROM SOIL

    Directory of Open Access Journals (Sweden)

    Janina Piekutin

    2015-06-01

    Full Text Available The paper presents studies on oil removal from soil by means of water elution with a help of shaking out the contaminants from the soil. The tests were performed on simulated soil samples contaminated with a mixture of petroleum hydrocarbons. The study consisted in recording the time influence and the number of elution cycles to remove contaminants from the soil. The samples were then subject to the determination of petroleum hydrocarbons, aliphatic hydrocarbons, and BTEX compounds (benzene, toluene, ethylbenzene, xylene. Due to adding various concentrations of petroleum into particular soil samples and applying different shaking times, it was possible to find out the impact of petroleum content and sample shaking duration on the course and possibility of petroleum substances removal by means of elution process.

  16. PRELIMINARY STUDY ON RETRO-REFLECTIVE COATED PAPER BASED ON MICRO-GLASS BEADS

    Institute of Scientific and Technical Information of China (English)

    YulongWang; ChuanshanZhao; TaoZhang

    2004-01-01

    High-reflectivity micro-glass bead, as a kind ofretro-reflective material, is widely used in reflectivefabric or film and other reflective coatings. But it israrely used in coated paper. The retro-reflectivetheory of micro-bead is described. Also the effect ofsize of micro-bead, dosage of binder and differentcolor layers on reflective properties of coated paperare discussed in this article. The results show that itsretro-reflective efficiency is good, equally toreflective fabric or film when the micro-glass bead isused in coated paper.

  17. PRELIMINARY STUDY ON RETRO-REFLECTIVE COATED PAPER BASED ON MICRO-GLASS BEADS

    Institute of Scientific and Technical Information of China (English)

    Yulong Wang; Chuanshan Zhao; Tao Zhang

    2004-01-01

    High-reflectivity micro-glass bead, as a kind of retro-reflective material, is widely used in reflective fabric or film and other reflective coatings. But it is rarely used in coated paper. The retro-reflective theory of micro-bead is described. Also the effect of size of micro-bead, dosage of binder and different color layers on reflective properties of coated paper are discussed in this article. The results show that its retro-reflective efficiency is good, equally to reflective fabric or film when the micro-glass bead is used in coated paper.

  18. Mechanisms of Very Late Drug-Eluting Stent Thrombosis Assessed by Optical Coherence Tomography

    DEFF Research Database (Denmark)

    Taniwaki, Masanori; Radu, Maria D; Zaugg, Serge

    2016-01-01

    BACKGROUND: The pathomechanisms underlying very late stent thrombosis (VLST) after implantation of drug-eluting stents (DES) are incompletely understood. Using optical coherence tomography, we investigated potential causes of this adverse event. METHODS AND RESULTS: Between August 2010 and Decemb...

  19. Processes Leading to Beaded Channels Formation in Central Yakutia

    Science.gov (United States)

    Tarbeeva, A. M.; Lebedeva, L.; Efremov, V. S.; Krylenko, I. V.; Surkov, V. V.

    2017-12-01

    Beaded channels, consisting of deepened and widened pools and connecting narrow runs, are common fluvial forms in permafrost regions. Recent studies have shown that beaded channels are very important for connecting alluvial rivers with headwater lakes allowing fish passage and foraging habitats, as well as regulating river runoff. Beaded channels are known as typical thermokarst landforms; however, there is no evidence of their origin and formative processes. Geomorphological analyzes of beaded channels have been completed in several permafrost regions including field observations of Shestakovka River in Central Yakutia. The study aims to recognize the modern exogenic processes and formative mechanisms of beaded river channels. We show that beaded channel of Shestakovka River form in the perennially frozen sand with low ice content, leading us to hypothesize that thermokarst is not the main process of formation. Due to the significant volume of water, the pools don't freeze over entirely during winters, even under harsh climatic conditions. As a result, lenses of pressurized water remain under surface ice underlain by perennially thawed sediments. The presence of thawed sediments under the pools and frozen sediments under the runs leads to uneven thermoerosion of the riverbed during floods, providing the beaded form of the channel. In addition, freezing of pools during winter leads to pressure increasing under ice cover and formation of ice mounds, which crack several times during winter leading to disturbance of riverbanks. Many 1st to 3rd order streams have a specific transitional meandering-to-beaded form resembling the shape of unconfined meandering rivers, but consisting of pools and runs. However, such channels exhibit no evidences of present-day erosion of concave banks and sediment accumulation at the convex banks as typically being observed in normally meandering rivers. Such forms of channels indicates that their formation occurred by the greater channel

  20. Preparation and testing of a tetra-amine copper(II) chitosan bead system for enhanced phosphate remediation.

    Science.gov (United States)

    Kumar, Ilango Aswin; Viswanathan, Natrayasamy

    2018-03-01

    A tetra-amine copper(II) chitosan bead system (TAC@CS composite beads) was developed by grafting tetra-amine copper(II) (TAC) with chitosan (CS) and utilized for phosphate removal. The prepared TAC@CS composite beads possess enhanced phosphate sorption capacity (SC) of 41.42 ± 0.071 mg/g than copper grafted chitosan (Cu@CS) composite, TAC and chitosan which were found to be 37.01 ± 0.803, 33.20 ± 0.650 and 7.24 ± 0.059 mg/g respectively. In batch mode, various adsorption influencing parameters like contact time, initial phosphate concentration, solution pH, co-anions and temperature were optimized for maximum phosphate sorption. The prepared adsorbents were characterized by FTIR, XRD, UV-Visible, SEM and EDAX analysis. The adsorption isotherms and thermodynamic parameters of the adsorbent were studied. The feasible phosphate uptake mechanism of TAC@CS biocomposite beads was reported. The reusability studies of TAC@CS composite beads were carried out using NaOH as elutant. The suitability of TAC@CS composite beads at field conditions was tested with phosphate contaminated field water samples collected from nearby areas of Dindigul district. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Enhancing the antimony sorption properties of nano titania-chitosan beads using epichlorohydrin as the crosslinker.

    Science.gov (United States)

    Nishad, Padala Abdul; Bhaskarapillai, Anupkumar; Velmurugan, Sankaralingam

    2017-07-15

    Antimony is classified as a pollutant of priority importance by USEPA. We have earlier reported the synthesis of nano-titania impregnated epichlorohydrin crosslinked chitosan (TA-Cts-Epi) beads, in a format suitable for large scale applications with high sorption capacity for antimony. To understand the sorption mechanism, and to fine tune the bead composition, the effect of crosslinking density on the swelling and sorption properties of the beads was investigated in detail. Epichlorohydrin effected significant changes in physical and sorption properties of the beads. The antimony sorption capacity of the TA-Cts-Epi beads prepared by crosslinking 0.3g non-crosslinked titania-chitosan beads (TA-Cts-NCL) with 6.4mmol epichlorohydrin was 493μmol/g, while those crosslinked with 0.64mmol showed a capacity of 133μmol/g. Whereas, TA-Cts-NCL beads showed a capacity of 75μmol/g. The increase in uptake capacity with increase in crosslinking demonstrated the active involvement of the epichlorohydrin moieties in antimony binding leading to enhanced sorption. Apart from altering the stability, swelling behaviour and sorption kinetics of the beads, crosslinking significantly increased the uptake of the anionic species via electrostatic interactions. Epichlorohydrin crosslinked chitosan beads prepared without TiO 2 also showed similar behaviour. The results demonstrated the involvement of chitosan, TiO 2 and epichlorohydrin in sorption. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Surface imprinted beads for the recognition of human serum albumin.

    Science.gov (United States)

    Bonini, Francesca; Piletsky, Sergey; Turner, Anthony P F; Speghini, Adolfo; Bossi, Alessandra

    2007-04-15

    The synthesis of poly-aminophenylboronic acid (ABPA) imprinted beads for the recognition of the protein human serum albumin (HSA) is reported. In order to create homogeneous recognition sites, covalent immobilisation of the template HSA was exploited. The resulting imprinted beads were selective for HSA. The indirect imprinting factor (IF) calculated from supernatant was 1.6 and the direct IF, evaluated from the protein recovered from the beads, was 1.9. The binding capacity was 1.4 mg/g, which is comparable to commercially available affinity materials. The specificity of the HSA recognition was evaluated with competitive experiments, indicating a molar ratio 4.5/1 of competitor was necessary to displace half of the bound HSA. The recognition and binding of the imprinted beads was also tested with a complex sample, human serum and targeted removal of HSA without a loss of the other protein components was demonstrated. The easy preparation protocol of derivatised beads and a good protein recognition properties make the approach an attractive solution to analytical and bio-analytical problems in the field of biotechnology.

  3. Removal of Uranium from Aqueous Solution by Alginate Beads

    Directory of Open Access Journals (Sweden)

    Jing Yu

    2017-04-01

    Full Text Available The adsorption of uranium (VI by calcium alginate beads was examined by batch experiments. The effects of environmental conditions on U (VI adsorption were studied, including contact time, pH, initial concentration of U (VI, and temperature. The alginate beads were characterized by using scanning electron microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy, and Fourier transform infrared spectroscopy. Fourier transform infrared spectra indicated that hydroxyl and alkoxy groups are present at the surface of the beads. The experimental results showed that the adsorption of U (VI by alginate beads was strongly dependent on pH, the adsorption increased at pH 3∼7, then decreased at pH 7∼9. The adsorption reached equilibrium within 2 minutes. The adsorption kinetics of U (VI onto alginate beads can be described by a pseudo first-order kinetic model. The adsorption isotherm can be described by the Redlich-Peterson model, and the maximum adsorption capacity was 237.15 mg/g. The sorption process is spontaneous and has an exothermic reaction.

  4. Removal of uranium from aqueous solution by aliginate beads

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Jing; Wang, Jian Long [Collaborative Innovation Center for Advanced Nuclear Energy Technology, INET, Tsinghua University, Beijing (China); Jiang, Yizhou [Northwest Institute of Nuclear Technology, Xian (China)

    2017-04-15

    The adsorption of uranium (VI) by calcium alginate beads was examined by batch experiments. The effects of environmental conditions on U (VI) adsorption were studied, including contact time, pH, initial concentration of U (VI), and temperature. The alginate beads were characterized by using scanning electron microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy, and Fourier transform infrared spectroscopy. Fourier transform infrared spectra indicated that hydroxyl and alkoxy groups are present at the surface of the beads. The experimental results showed that the adsorption of U (VI) by alginate beads was strongly dependent on pH, the adsorption increased at pH 3∼7, then decreased at pH 7∼9. The adsorption reached equilibrium within 2 minutes. The adsorption kinetics of U (VI) onto alginate beads can be described by a pseudo first-order kinetic model. The adsorption isotherm can be described by the Redlich-Peterson model, and the maximum adsorption capacity was 237.15 mg/g. The sorption process is spontaneous and has an exothermic reaction.

  5. Controlled antiseptic release by alginate polymer films and beads.

    Science.gov (United States)

    Liakos, Ioannis; Rizzello, Loris; Bayer, Ilker S; Pompa, Pier Paolo; Cingolani, Roberto; Athanassiou, Athanassia

    2013-01-30

    Biodegradable polymeric materials based on blending aqueous dispersions of natural polymer sodium alginate (NaAlg) and povidone iodine (PVPI) complex, which allow controlled antiseptic release, are presented. The developed materials are either free standing NaAlg films or Ca(2+)-cross-linked alginate beads, which properly combined with PVPI demonstrate antibacterial and antifungal activity, suitable for therapeutic applications, such as wound dressing. Glycerol was used as the plasticizing agent. Film morphology was studied by optical and atomic force microscopy. It was found that PVPI complex forms well dispersed circular micro-domains within the NaAlg matrix. The beads were fabricated by drop-wise immersion of NaAlg/PVPI/glycerol solutions into aqueous calcium chloride solutions to form calcium alginate beads encapsulating PVPI solution (CaAlg/PVPI). Controlled release of PVPI was possible when the composite films and beads were brought into direct contact with water or with moist media. Bactericidal and fungicidal properties of the materials were tested against Escherichia coli bacteria and Candida albicans fungi. The results indicated very efficient antibacterial and antifungal activity within 48 h. Controlled release of PVPI into open wounds is highly desired in clinical applications to avoid toxic doses of iodine absorption by the wound. A wide variety of applications are envisioned such as external and internal wound dressings with controlled antiseptic release, hygienic and protective packaging films for medical devices, and polymer beads as water disinfectants. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. EXPERIMENTAL TESTING OF DRAW-BEAD RESTRAINING FORCE IN SHEET METAL FORMING

    Institute of Scientific and Technical Information of China (English)

    J.H. Yang; J. Chen; D.N. He; X. Y. Ruan

    2003-01-01

    Due to complexities of draw-bead restraining force calculated according to theory anddepending on sheet metal forming properties experiment testing system, a simplifiedmethod to calculate draw-bead restraining force is put forward by experimental methodin cup-shaped drawing process. The experimental results were compared with numer-ical results and proved agreement. It shows the method is effective.

  7. Comparison of paclitaxel- and sirolimus-eluting stents in everyday clinical practice: the SORT OUT II randomized trial

    DEFF Research Database (Denmark)

    Galløe, Anders M; Thuesen, Leif; Kelbaek, Henning

    2008-01-01

    Approval of drug-eluting coronary stents was based on results of relatively small trials of selected patients; however, in routine practice, stents are used in a broader spectrum of patients.......Approval of drug-eluting coronary stents was based on results of relatively small trials of selected patients; however, in routine practice, stents are used in a broader spectrum of patients....

  8. Softening and elution of monomers in ethanol

    DEFF Research Database (Denmark)

    Benetti, Ana Raquel; Asmussen, Erik; Munksgaard, E Christian

    2009-01-01

    The purpose of this study was to investigate the effect of light-curing protocol on softening and elution of monomers in ethanol as measured on a model polymer. It was a further aim to correlate the measured values with previously reported data on degree of conversion and glass transition...

  9. Early Diagnosis of Irkut Virus Infection Using Magnetic Bead-Based Serum Peptide Profiling by MALDI-TOF MS in a Mouse Model

    Directory of Open Access Journals (Sweden)

    Nan Li

    2014-03-01

    Full Text Available Early diagnosis is important for the prompt post-exposure prophylaxis of lyssavirus infections. To diagnose Irkut virus (IRKV infection during incubation in mice, a novel method using magnetic bead-based serum peptide profiling by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS has been established. For this test, serum peptides were concentrated by adsorption to and elution from the magnetic bead-based weak cation ion exchanger. Mass spectrograms obtained by MALDI-TOF MS were analyzed using ClinProTools bioinformatics software. Construction of the diagnostic model was performed using serum samples from mice infected with IRKV and rabies virus (RABV BD06, Flury-LEP, and SRV9 (as controls. The method accurately diagnosed sera 2, 4 and 8 days after IRKV and RABV infections. The sensitivity, specificity, and total accuracy of diagnosis were 86.7%, 95.2%, and 92.9%, respectively. However, IRKV could not be differentiated from RABV 1 day after infection. The results of the present study indicate that serum peptide profiling by MALDI-TOF MS is a promising technique for the early clinical diagnosis of lyssavirus infections and needs to be further tested in humans and farm animals.

  10. A Pneumatic Actuated Microfluidic Beads-Trapping Device

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Guocheng; Cai, Ziliang; Wang, Jun; Wang, Wanjun; Lin, Yuehe

    2011-08-20

    The development of a polydimethylsiloxane (PDMS) microfluidic microbeads trapping device is reported in this paper. Besides fluid channels, the proposed device includes a pneumatic control chamber and a beads-trapping chamber with a filter array structure. The pneumatic flow control chamber and the beads-trapping chamber are vertically stacked and separated by a thin membrane. By adjusting the pressure in the pneumatic control chamber, the membrane can either be pushed against the filter array to set the device in trapping mode or be released to set the device in releasing mode. In this paper, a computational fluid dynamics simulation was conducted to optimize the geometry design of the filter array structure; the device fabrication was also carried out. The prototype device was tested and the preliminary experimental results showed that it can be used as a beads-trapping unit for various biochemistry and analytical chemistry applications, especially for flow injection analysis systems.

  11. The dispersion of fine chitosan particles by beads-milling

    Science.gov (United States)

    Rochima, Emma; Utami, Safira; Hamdani, Herman; Azhary, Sundoro Yoga; Praseptiangga, Danar; Joni, I. Made; Panatarani, Camellia

    2018-02-01

    This research aimed to produce fine chitosan particles from a crab shell waste by beads-milling method by two different concentration of PEG as dispersing agent (150 and 300 wt. %). The characterization was performed to obtain the size and size distribution, the characteristics of functional groups and the degree of deacetylation. The results showed that the chitosan fine particles was obtained with a milling time 120 minutes with the best concentration of PEG 400 150 wt. %. The average particle size of the as-prepared suspension is 584 nm after addition of acetic acid solution (1%, v/v). Beads milling process did not change the glucosamine and N-acetylglucosamine content on chitosan structure which is indicated by degree of deacetylation higher than 70%. It was concluded that beads milling process can be applied to prepare chitosan fineparticles by proper adjustment in the milling time, pH and dosage of dispersing agent.

  12. Comparison of an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent for the treatment of coronary artery stenosis (ABSORB II): a 3 year, randomised, controlled, single-blind, multicentre clinical trial

    NARCIS (Netherlands)

    Serruys, Patrick W.; Chevalier, Bernard; Sotomi, Yohei; Cequier, Angel; Carrié, Didier; Piek, Jan J.; van Boven, Ad J.; Dominici, Marcello; Dudek, Dariusz; McClean, Dougal; Helqvist, Steffen; Haude, Michael; Reith, Sebastian; de Sousa Almeida, Manuel; Campo, Gianluca; Iñiguez, Andrés; Sabaté, Manel; Windecker, Stephan; Onuma, Yoshinobu

    2016-01-01

    No medium-term data are available on the random comparison between everolimus-eluting bioresorbable vascular scaffolds and everolimus-eluting metallic stents. The study aims to demonstrate two mechanistic properties of the bioresorbable scaffold: increase in luminal dimensions as a result of

  13. Alendronate-Eluting Biphasic Calcium Phosphate (BCP Scaffolds Stimulate Osteogenic Differentiation

    Directory of Open Access Journals (Sweden)

    Sung Eun Kim

    2015-01-01

    Full Text Available Biphasic calcium phosphate (BCP scaffolds have been widely used in orthopedic and dental fields as osteoconductive bone substitutes. However, BCP scaffolds are not satisfactory for the stimulation of osteogenic differentiation and maturation. To enhance osteogenic differentiation, we prepared alendronate- (ALN- eluting BCP scaffolds. The coating of ALN on BCP scaffolds was confirmed by scanning electron microscopy (FE-SEM, energy-dispersive X-ray spectroscopy (EDS, and attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR. An in vitro release study showed that release of ALN from ALN-eluting BCP scaffolds was sustained for up to 28 days. In vitro results revealed that MG-63 cells grown on ALN-eluting BCP scaffolds exhibited increased ALP activity and calcium deposition and upregulated gene expression of Runx2, ALP, OCN, and OPN compared with the BCP scaffold alone. Therefore, this study suggests that ALN-eluting BCP scaffolds have the potential to effectively stimulate osteogenic differentiation.

  14. Boron removal from aqueous solutions by ion-exchange resin: Column sorption-elution studies

    International Nuclear Information System (INIS)

    Koese, T. Ennil; Oztuerk, Nese

    2008-01-01

    A column sorption-elution study was carried out by using a strong base anion-exchange resin (Dowex 2 x 8) for the removal of boron from aqueous solutions. The breakthrough curve was obtained as a function of feed flow rate and the total and breakthrough capacity values of the resin were calculated. The boron on the resin was quantitatively eluted with 0.5 M HCl solution at different flow rates. Three consecutive sorption-elution-washing-regeneration-washing cycles were applied to the resin in order to investigate the reusability of the ion-exchange resin. Total capacity values remained almost the same after three sorption-elution-regeneration cycles. The Thomas and the Yoon-Nelson models were applied to experimental data to predict the breakthrough curves and to determine the characteristic column parameters required for process design. The results proved that the models would describe the breakthrough curves well

  15. The Surface Imprinted Polystyrene Beads Prepared via Emulsion Templates

    Institute of Scientific and Technical Information of China (English)

    Guo Xiang CHENG; Guang Ling PEI; Ling Gang ZENG; Li Yong ZHANG; Chao LIU

    2004-01-01

    In this paper, the surface imprinted cross-linked polystyrene beads were prepared via suspension polymerization with styrene (St), divinylbezene (DVB), polyvinyl alcohol (PVA1788), the mixture of Span 85 and xylene or the mixture of Span 85 and paraffin as monomer, cross-linking agent, dispersion stabilizer and templates, respectively. The results indicate that there are dense cavities on the surface of beads, and the diameter and density of cavity are related with the composition and amount of emulsion template. The forming mechanism of cavity from thermodynamics and dynamics was proposed.

  16. Heparin monotherapy or bivalirudin during percutaneous coronary intervention in patients with non-ST-segment-elevation acute coronary syndromes or stable ischemic heart disease: results from the Evaluation of Drug-Eluting Stents and Ischemic Events registry.

    Science.gov (United States)

    Bangalore, Sripal; Pencina, Michael J; Kleiman, Neal S; Cohen, David J

    2014-06-01

    The use of bivalirudin versus unfractionated heparin monotherapy in patients without ST-segment-elevation myocardial infarction is not well defined. The study population consisted of patients enrolled in the Evaluation of Drug-Eluting Stents and Ischemic Events (EVENT) registry with either non-ST-segment-elevation acute coronary syndromes or stable ischemic heart disease, who underwent percutaneous coronary intervention with either unfractionated heparin or bivalirudin monotherapy. Propensity score matching was used to adjust for baseline characteristics. The primary bleeding (in-hospital composite bleeding-access site bleeding, thrombolysis in myocardial infarction major/minor bleeding, or transfusion) and primary (in-hospital death/myocardial infarction) and secondary ischemic outcomes (death/myocardial infarction/unplanned repeat revascularization at 12 months) were evaluated. Propensity score matching yielded 1036 patients with non-ST-segment-elevation acute coronary syndromes and 2062 patients with stable ischemic heart disease. For the non-ST-segment-elevation acute coronary syndrome cohort, bivalirudin use was associated with lower bleeding (difference, -3.3% [-0.8% to -5.8%]; P=0.01; number need to treat=30) without increase in either primary (difference, 1.2% [4.1% to -1.8%]; P=0.45) or secondary ischemic outcomes, including stent thrombosis (difference, 0.0% [1.3% to -1.3%]; P=1.00). Similarly, in the stable ischemic heart disease cohort, bivalirudin use was associated with lower bleeding (difference, -1.8% [-0.4% to -3.3%]; P=0.01; number need to treat=53) without increase in either primary (difference, 0.4% [2.3% to -1.5%]; P=0.70) or secondary ischemic outcomes, including stent thrombosis (difference, 0.0% [0.7% to -0.7%]; P=1.00) when compared with unfractionated heparin monotherapy. Among patients with non-ST-segment-elevation acute coronary syndromes or stable ischemic heart disease undergoing percutaneous coronary intervention, bivalirudin use

  17. Miniaturized bead-beating device to automate full DNA sample preparation processes for gram-positive bacteria.

    Science.gov (United States)

    Hwang, Kyu-Youn; Kwon, Sung Hong; Jung, Sun-Ok; Lim, Hee-Kyun; Jung, Won-Jong; Park, Chin-Sung; Kim, Joon-Ho; Suh, Kahp-Yang; Huh, Nam

    2011-11-07

    We have developed a miniaturized bead-beating device to automate nucleic acids extraction from Gram-positive bacteria for molecular diagnostics. The microfluidic device was fabricated by sandwiching a monolithic flexible polydimethylsiloxane (PDMS) membrane between two glass wafers (i.e., glass-PDMS-glass), which acted as an actuator for bead collision via its pneumatic vibration without additional lysis equipment. The Gram-positive bacteria, S. aureus and methicillin-resistant S. aureus, were captured on surface-modified glass beads from 1 mL of initial sample solution and in situ lyzed by bead-beating operation. Then, 10 μL or 20 μL of bacterial DNA solution was eluted and amplified successfully by real-time PCR. It was found that liquid volume fraction played a crucial role in determining the cell lysis efficiency in a confined chamber by facilitating membrane deflection and bead motion. The miniaturized bead-beating operation disrupted most of S. aureus within 3 min, which turned out to be as efficient as the conventional benchtop vortexing machine or the enzyme-based lysis technique. The effective cell concentration was significantly enhanced with the reduction of initial sample volume by 50 or 100 times. Combination of such analyte enrichment and in situ bead-beating lysis provided an excellent PCR detection sensitivity amounting to ca. 46 CFU even for the Gram-positive bacteria. The proposed bead-beating microdevice is potentially useful as a nucleic acid extraction method toward a PCR-based sample-to-answer system. This journal is © The Royal Society of Chemistry 2011

  18. Comparison of non-magnetic and magnetic beads in bead-based assays

    NARCIS (Netherlands)

    Hansenová Maňásková, S.; van Belkum, A.; Endtz, H.P.; Bikker, F.J.; Veerman, E.C.I.; van Wamel, W.J.B.

    2016-01-01

    Multiplex bead-based flow cytometry is an attractive way for simultaneous, rapid and cost-effective analysis of multiple analytes in a single sample. Previously, we developed various bead-based assays using non-magnetic beads coated with Staphylococcus aureus and Streptococcus pneumoniae antigens

  19. Beautiful Beads: A Lesson in Making Beads with Friendly Clay. AMACO[R] Lesson.

    Science.gov (United States)

    Gamble, Harriet; Gamble, David

    This lesson resource includes a brief summary of the history of bead making and historic fascination with beads as adornment. A focus on design elements, color theory, craftsmanship, and technical skill in bead making is encouraged. The plan includes lesson goals and objectives; background preparation; a glossary of terms; a list of supplies; and…

  20. Chemical–physical characterisation of Early Iron Age glass beads from Central Europe

    Energy Technology Data Exchange (ETDEWEB)

    Agua, F.; Conde, J.F.; Kobylińska, U.; Kobyliński, Z.; García-Heras, M.; Villegas, M.A.

    2017-07-01

    Archaeological excavation of the Institute of Archaeology and Ethnology (Polish Academy of Sciences, PAN) at several Iron Age sites located in West Poland and South Germany has allowed the recovery of an important set of coloured glass beads mostly decorated (6th–4th centuries BC). The present paper summarises the results obtained through the chemical and microstructural characterisation of such beads. The research was carried out by binocular microscope observations, X-ray diffraction, scanning electron microscopy, energy dispersive X-ray spectrometry and visible spectrophotometry. The main objective was to attain information on the production technology and conservation state of these beads. The results indicated that all them were produced with soda lime silicate glass, even though two groups can be separated: (i) beads containing high MgO percentages made from plant ashes as an alkaline source, and (ii) beads containing low MgO percentages made from natron as an alkaline source. As regards decorations, opaque white was obtained from tin oxide, turquoise blue from Cu2+-ions, and opaque yellow from lead antimonate. Additionally, results showed microstructural and microcrystalline differences between some glass beads studied here and other glass beads from Mediterranean areas, dated in the same chronological period. This fact pointed out the valuable role given to these beads by Iron Age communities from Central Europe. (Author)

  1. Development of an elution device for ViroCap virus filters.

    Science.gov (United States)

    Fagnant, Christine Susan; Toles, Matthew; Zhou, Nicolette Angela; Powell, Jacob; Adolphsen, John; Guan, Yifei; Ockerman, Byron; Shirai, Jeffry Hiroshi; Boyle, David S; Novosselov, Igor; Meschke, John Scott

    2017-10-19

    Environmental surveillance of waterborne pathogens is vital for monitoring the spread of diseases, and electropositive filters are frequently used for sampling wastewater and wastewater-impacted surface water. Viruses adsorbed to electropositive filters require elution prior to detection or quantification. Elution is typically facilitated by a peristaltic pump, although this requires a significant startup cost and does not include biosafety or cross-contamination considerations. These factors may pose a barrier for low-resource laboratories that aim to conduct environmental surveillance of viruses. The objective of this study was to develop a biologically enclosed, manually powered, low-cost device for effectively eluting from electropositive ViroCap™ virus filters. The elution device described here utilizes a non-electric bilge pump, instead of an electric peristaltic pump or a positive pressure vessel. The elution device also fully encloses liquids and aerosols that could contain biological organisms, thereby increasing biosafety. Moreover, all elution device components that are used in the biosafety cabinet are autoclavable, reducing cross-contamination potential. This device reduces costs of materials while maintaining convenience in terms of size and weight. With this new device, there is little sample volume loss due to device inefficiency, similar virus yields were demonstrated during seeded studies with poliovirus type 1, and the time to elute filters is similar to that required with the peristaltic pump. The efforts described here resulted in a novel, low-cost, manually powered elution device that can facilitate environmental surveillance of pathogens through effective virus recovery from ViroCap filters while maintaining the potential for adaptability to other cartridge filters.

  2. Brownian dynamics simulations with stiff finitely extensible nonlinear elastic-Fraenkel springs as approximations to rods in bead-rod models.

    Science.gov (United States)

    Hsieh, Chih-Chen; Jain, Semant; Larson, Ronald G

    2006-01-28

    A very stiff finitely extensible nonlinear elastic (FENE)-Fraenkel spring is proposed to replace the rigid rod in the bead-rod model. This allows the adoption of a fast predictor-corrector method so that large time steps can be taken in Brownian dynamics (BD) simulations without over- or understretching the stiff springs. In contrast to the simple bead-rod model, BD simulations with beads and FENE-Fraenkel (FF) springs yield a random-walk configuration at equilibrium. We compare the simulation results of the free-draining bead-FF-spring model with those for the bead-rod model in relaxation, start-up of uniaxial extensional, and simple shear flows, and find that both methods generate nearly identical results. The computational cost per time step for a free-draining BD simulation with the proposed bead-FF-spring model is about twice as high as the traditional bead-rod model with the midpoint algorithm of Liu [J. Chem. Phys. 90, 5826 (1989)]. Nevertheless, computations with the bead-FF-spring model are as efficient as those with the bead-rod model in extensional flow because the former allows larger time steps. Moreover, the Brownian contribution to the stress for the bead-FF-spring model is isotropic and therefore simplifies the calculation of the polymer stresses. In addition, hydrodynamic interaction can more easily be incorporated into the bead-FF-spring model than into the bead-rod model since the metric force arising from the non-Cartesian coordinates used in bead-rod simulations is absent from bead-spring simulations. Finally, with our newly developed bead-FF-spring model, existing computer codes for the bead-spring models can trivially be converted to ones for effective bead-rod simulations merely by replacing the usual FENE or Cohen spring law with a FENE-Fraenkel law, and this convertibility provides a very convenient way to perform multiscale BD simulations.

  3. OBT analysis method using polyethylene beads for limited quantities of animal tissue

    International Nuclear Information System (INIS)

    Kim, S.B.; Stuart, M.

    2015-01-01

    This study presents a polyethylene beads method for OBT determination in animal tissues and animal products for cases where the amount of water recovered by combustion is limited by sample size or quantity. In the method, the amount of water recovered after combustion is enhanced by adding tritium-free polyethylene beads to the sample prior to combustion in an oxygen bomb. The method reduces process time by allowing the combustion water to be easily collected with a pipette. Sufficient water recovery was achieved using the polyethylene beads method when 2 g of dry animal tissue or animal product were combusted with 2 g of polyethylene beads. Correction factors, which account for the dilution due to the combustion water of the beads, are provided for beef, chicken, pork, fish and clams, as well as egg, milk and cheese. The method was tested by comparing its OBT results with those of the conventional method using animal samples collected on the Chalk River Laboratories (CRL) site. The results determined that the polyethylene beads method added no more than 25% uncertainty when appropriate correction factors are used. - Highlights: • Polyethylene beads method for OBT determination in animal tissues and animal products were determined. • The method reduces process time. • The polyethylene beads method added no more than 25% uncertainty when appropriate correction factors are used

  4. Radioactive cesium elution speed in dried wild Mushrooms collected in 2015

    International Nuclear Information System (INIS)

    Yamaguchi, Toshiro; Arai, Hirotsugu; Ohnuma, Tohru; Arai, Hiromu; Takyu, Sodai; Matsuyama, Tetsuo; Ishii, Keizo

    2016-01-01

    Dried wild mushrooms (12 species, 13 samples) collected in Nagano, Fukushima, and Miyagi Prefectures, Japan, in 2015 were immersed in water for 1,440 min. The elution rate of radioactive cesium (Cs) was calculated based on its radioactivity, which was measured with a high-purity germanium semiconductor detector (GX2018; CANBERRA Industries, Meriden, CT, USA) before and after immersion for each mushroom. Immersion fluid was sampled after 10, 30, 60, 180, 360, and 1,440 min of immersion and dried on aluminum foil. Then, imaging plates (BAS-III, Fujifilm, Tokyo, Japan) exposed to the dried immersion fluid were measured with a Bio-imaging Analyzer System-1800 II (Fujifilm). The 50% elution time of each wild mushroom was calculated based on the photo stimulated luminescence density of the autoradiographs. The radioactive Cs elution rate was > 80% for 11 samples (84% of total) comprising 11 mushroom species. Moreover, the 50% elution time was < 30 min for 9 samples (69% of total) comprising 9 species. This shows that the radioactive Cs elution rate and elution speed were not constant among mushroom species. Based on these results, immersing the mushrooms, which were dried, in water for at least 120 min is an effective method for removing radioactive Cs from wild mushrooms. (author)

  5. StoryBeads: Preserving indigenous knowledge through tangible interaction design

    CSIR Research Space (South Africa)

    Reitsma, L

    2013-09-01

    Full Text Available in technology adoption. The study resulted in a recording device that fits the target group’s oral tradition and is based on a concept in which oral stories are recorded and associated with tangible beads that can be incorporated into traditional beadwork...

  6. Elastase-coupled beads as a tool for characterizing localized alveolar tissue destruction associated with the onset of emphysema

    Science.gov (United States)

    Craig, J. M.; Scott, A. L.

    2013-01-01

    Intratracheal elastase challenge of laboratory animals has long been established as a model for observing the physiological and morphological changes that result from alveolar destruction, the hallmark of emphysema. However, instillation of elastase suspended in buffer results in widespread inflammation and variable emphysematous lesions, which has made the identification of specific cellular and molecular events associated with the onset of emphysema difficult to define. Here we establish a bead-based elastase delivery system that induces localized tissue destruction, a key event in the initiation of emphysema. Elastase was coupled to bisacrylamide beads, which were shown to retain enzymatic activity prior to intratracheal administration in mice. C57BL/6 mice were given a single dose of 40,000 beads, which became distributed throughout the small airways and parenchyma of the lung. Elastase-coupled beads resulted in a quantifiable loss of alveolar tissue immediately surrounding the beads, an effect that was not observed with beads that lacked protein altogether or with beads containing elastase inactivated by an irreversible inhibitor. Furthermore, beads bound with active elastase elicited local recruitment of mononuclear cells, including macrophages, and polymorphonuclear neutrophils to the site of bead deposition, a feature consistent with the cellular infiltration observed following conventional solubilized elastase challenges. This work identifies a novel bead-based enzyme delivery system that also extends the elastase model of emphysema to permit the characterization of mechanisms that drive alveolar surface area loss following elastin degradation in focal emphysematous lesions. PMID:23558388

  7. Magnetic nanoparticle-loaded alginate beads for local micro-actuation of in vitro tissue constructs.

    Science.gov (United States)

    Alshehri, Awatef M; Wilson, Otto C; Dahal, Bishnu; Philip, John; Luo, Xiaolong; Raub, Christopher B

    2017-11-01

    Magnetic nanoparticles (MNPs) self-align and transduce magnetic force, two properties which lead to promising applications in cell and tissue engineering. However, the toxicity of MNPs to cells which uptake them is a major impediment to applications in engineered tissue constructs. To address this problem, MNPs were embedded in millimeter-scale alginate beads, coated with glutaraldehyde cross-linked chitosan, and loaded in acellular and MDA-MB-231 cancer cell-seeded collagen hydrogels, providing local micro-actuation under an external magnetic field. Brightfield microscopy was used to assess nanoparticle diffusion from the bead. Phase contrast microscopy and digital image correlation were used to track collagen matrix displacement and estimate intratissue strain under magnetic actuation. Coating the magnetic alginate beads with glutaraldehyde-chitosan prevents bulk diffusion of nanoparticles into the surrounding microenvironment. Further, the beads exert force on the surrounding collagen gel and cells, resulting in intratissue strains of 0-10% tunable with bead dimensions, collagen density, and distance from the bead. Cells seeded adjacent to the embedded beads are subjected to strain gradients without loss of cell viability over two days culture. This study describes a simple way to fabricate crosslinked magnetic alginate beads to load in a collagen tissue construct without direct exposure of the construct to nanoparticles. The findings are significant to in vitro studies of mechanobiology in enabling precise control over dynamic mechanical loading of tissue constructs. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Preparation of chitosan/amino multiwalled carbon nanotubes nanocomposite beads for bilirubin adsorption in hemoperfusion.

    Science.gov (United States)

    Zong, Wenhui; Chen, Jian; Han, Wenyan; Chen, Jie; Wang, Yue; Wang, Weichao; Cheng, Guanghui; Ou, Lailiang; Yu, Yaoting

    2018-01-01

    Chitosan-carbon nanotube composite beads combines the advantages of chitosan in forming a stable biocompatible framework and carbon nanotube that provide nanometer effects (high strength and high specific surface area etc.). In this study, chitosan/amino multiwalled carbon nanotubes (CS/AMWCNT) composite beads was prepared by phase-inversion method, in which CS and AMWCNT was crosslinked by ethylene glycol diglycidyl ether (EGDE). The CS/AMWCNT nanocomposite beads produced has been characterized by BET, SEM, TGA, and Raman spectroscopy which exhibited enhanced thermal stability due to the incorporation of AMWCNT. Mechanical test results showed that mechanical strength of the CS/AMWCNT composite beads was significantly enhanced when comparing to unmodified chitosan beads, the breakage percentage decreased from 34.1% to 0.67%. The adsorption capacity for bilirubin was measured in PBS and BSA solutions, and the CS/AMWCNT composite beads with 5 wt% AMWCNT showed much higher adsorption capacity (12.7 mg/g in PBS and 7.6 mg/g in BSA) to bilirubin than chitosan beads (8.5 mg/g in PBS and 4.2 mg/g in BSA). Our nanocomposite beads with excellent hemocompatibility has a high potential application in blood purification as an efficient adsorbent for bilirubin. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 96-103, 2018. © 2016 Wiley Periodicals, Inc.

  9. In vivo cleansing efficacy of biodegradable exfoliating beads assessed by skin bioengineering techniques.

    Science.gov (United States)

    Kitsongsermthon, J; Duangweang, K; Kreepoke, J; Tansirikongkol, A

    2017-11-01

    The plastic microbeads, used in many cleansers, will be banned in cosmetic and personal care products within 2017 since they are non-degradable and can disturb the living organisms in water reservoirs. Various choices of biodegradable beads are commercially available, but their efficacy has not been proven yet. This study aimed to compare the cleansing efficacy in dirt and sebum removal aspects of three types of exfoliating beads. The gel scrubs with polyethylene (PE) beads, mannan beads or wax beads, were formulated and evaluated for their stability. The in vivo evaluation was done in 38 healthy volunteers and the skin irritation, efficacy for dirt and sebum removal were measured by Mexameter ® , Colorimeter ® , and Sebumeter ® , respectively. The selected gel scrubs did not cause an irritation in any volunteers. The differences in dirt residues between before and after scrubbing were not statistically significant among three gel scrubs and the similar result was also reported in the sebum removal study. All gel scrubs demonstrated the comparable cleansing efficacy in term of dirt and sebum removal. Thus, mannan beads and wax beads may be replaced non-biodegradable PE beads to achieve the similar cleansing effect. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Preparation and Characterization of Highly Spherical Silica-titania Aerogel Beads with High Surface Area

    Directory of Open Access Journals (Sweden)

    YU Yu-xi

    2017-02-01

    Full Text Available The silica-titania aerogel beads were synthesized through sol-gel reaction followed by supercritical drying, in which TEOS and TBT as co-precursors, EtOH as solvents, HAC and NH3·H2O as catalysts. The as-prepared aerogel beads were characterized by SEM,TEM,XRD,FT-IR,TG-DTA and nitrogen adsorption-desorption. The results indicate that the diameter distribution of beads are between 1-8mm, the average diameter of beads is 3.5mm. The aerogel beads have nanoporous network structure with high specific surface area of 914.5m2/g, and the TiO2 particles are distributed in the aerogel uniformly, which keep the anatase crystal under high temperature.

  11. Investigation on rare earth magnets recycling by organophosphoric extractant encapsulated polymeric beads for separation of dysprosium

    International Nuclear Information System (INIS)

    Yadav, Kartikey K.; Singh, D.K.; Kain, V.

    2017-01-01

    Rare earth elements (REEs) are a basic requirement of the electronics and new industries including green technology. In the present work an organophosphoric extractant encapsulating polyethersulfone (PES) beads has been developed and employed for dysprosium (Dy) separation from aqueous stream. Polyethersulfonic beads encapsulating PC88A were prepared by phase inversion method. During the synthesis of the beads, preparatory parameters were also optimized to obtain best suited beads which were subsequently characterized for their encapsulation capacity and micro structural investigation. The results obtained in the present investigation suggested that PES/PVAJPC88A composite beads could be used for separation of rare earths from aqueous medium obtained from the solubilisation of magnetic scrap materials

  12. Hierarchically templated beads with tailored pore structure for phosphopeptide capture and phosphoproteomics

    DEFF Research Database (Denmark)

    Wierzbicka, Celina; Torsetnes, Silje B.; Jensen, Ole N.

    2017-01-01

    Two templating approaches to produce imprinted phosphotyrosine capture beads with a controllable pore structure are reported and compared with respect to their ability to enrich phosphopeptides from a tryptic peptide mixture. The beads were prepared by the polymerization of urea-based host monomers...... and crosslinkers inside the pores of macroporous silica beads with both free and immobilized template. In the final step the silica was removed by fluoride etching resulting in mesoporous polymer replicas with narrow pore size distributions, pore diameters ≈ 10 nm and surface area > 260 m2 g-1. The beads displayed...... pronounced phosphotyrosine affinity and selectivity in binding tests using model peptides in acetonitrile rich solutions with a performance surpassing solution polymerized bulk imprinted materials. Tests of the beads for the enrichment of phosphopeptides from tryptic digests of twelve proteins revealed both...

  13. A Phos-tag-based magnetic-bead method for rapid and selective separation of phosphorylated biomolecules.

    Science.gov (United States)

    Tsunehiro, Masaya; Meki, Yuma; Matsuoka, Kanako; Kinoshita-Kikuta, Emiko; Kinoshita, Eiji; Koike, Tohru

    2013-04-15

    A simple and efficient method based on magnetic-bead technology has been developed for the separation of phosphorylated and nonphosphorylated low-molecular-weight biomolecules, such as nucleotides, phosphorylated amino acids, or phosphopeptides. The phosphate-binding site on the bead is an alkoxide-bridged dinuclear zinc(II) complex with 1,3-bis(pyridin-2-ylmethylamino)propan-2-olate (Phos-tag), which is linked to a hydrophilic cross-linked agarose coating on a magnetic core particle. All steps for the phosphate-affinity separation are conducted in buffers of neutral pH with 50 μL of the magnetic beads in a 1.5-mL microtube. The entire separation protocol for phosphomonoester-type compounds, from addition to elution, requires less than 12 min per sample if the buffers and the zinc(II)-bound Phos-tag magnetic beads have been prepared in advance. The phosphate-affinity magnetic beads are reusable at least 15 times without a decrease in their phosphate-binding ability and they are stable for three months in propan-2-ol. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Preparation of Polymeric Resin Beads Using Gamma Irradiation and Chemical Processes for Use in the Recovery of Some Alkali Metal Ions

    International Nuclear Information System (INIS)

    El-Nahas, H. H.; Khalil, F. H.; Ibrahim, G. M.; El-Gammal, B.

    2007-01-01

    Syntheses of resin beads from unsaturated polyester and urea-formaldehyde were carried out by dispersion polymerization. The reaction was performed through gamma irradiation and chemical processing. Factors affecting the reaction and syntheses parameters that are the type and viscosity of dispersant, irradiation dose and agitation rate on the resin beads size were thoroughly investigated. The resulting resin beads were smooth on their spherical surface and the beads diameters were in the range 2-200μm. Some measurements such as beads diameter, surface hardness and scanning electron microscopy were studied. The bead diameter was generally decreased with increasing concentration and viscosity of the dispersant and agitation rate. A comparison study between irradiation and chemical processes for resin beads synthesis was discussed to identify the suitable process for preparing a resin beads in a pilot scale. The different methods of preparation were tried to be applied in the recovery of Li + , Na+, k + and Cs + ions from acidic media.

  15. Randomised comparison of a bioresorbable everolimus-eluting scaffold with a metallic everolimus-eluting stent for ischaemic heart disease caused by de novo native coronary artery lesions

    DEFF Research Database (Denmark)

    Chevalier, Bernard; Onuma, Yoshinobu; van Boven, Ad J

    2016-01-01

    AIMS: The one-year randomised data of the ABSORB II trial showed that the everolimus-eluting bioresorbable scaffold and the everolimus-eluting metallic stent were comparable for the composite secondary clinical outcomes of patient-oriented composite endpoint (PoCE) and device-oriented composite...... Clara, CA, USA) or treatment with an everolimus-eluting metallic stent (XIENCE; Abbott Vascular). The trial enrolled 501 patients. Clinical follow-up at two years was available in 320 patients in the Absorb BVS arm and 160 patients in the XIENCE arm. At two years, the PoCE for the Absorb and XIENCE arms......-six percent and 34% of patients remained on DAPT at two years, respectively. Ninety-two percent of patients in both arms remained on aspirin. CONCLUSIONS: Two-year clinical results demonstrate sustained low rates of PoCE, MACE, DoCE and TVF with the Absorb BVS as compared to the XIENCE stent....

  16. Low-cost commercial glass beads as dosimeters in radiotherapy

    International Nuclear Information System (INIS)

    Jafari, S.M.; Bradley, D.A.; Gouldstone, C.A.; Sharpe, P.H.G.; Alalawi, A.; Jordan, T.J.; Clark, C.H.; Nisbet, A.; Spyrou, N.M.

    2014-01-01

    Recent developments in advanced radiotherapy techniques using small field photon beams, require small detectors to determine the delivered dose in steep dose gradient fields. Commercially available glass jewellery beads exhibit thermoluminescent properties and have the potential to be used as dosimeters in radiotherapy due to their small size ( 60 Co gamma rays over doses ranging from 1 to 2500 cGy. A thermoluminescence (TL) system and an electron paramagnetic resonance (EPR) system were employed for read out. Both the TL and EPR studies demonstrated a radiation-induced signal, the sensitivity of which varied with bead colour. White coloured beads proved to be the most sensitive for both systems. The smallest and therefore least sensitive bead sizes allowed measurement of doses of 1 cGy using the TL system while that for the EPR system was approximately 1000 cGy. The fading rate was found to be 10% 30 days after irradiation with both readout systems. The dose response is linear with measured dose over the dose range 1 to 2500 cGy, with an R 2 correlation coefficient of greater than 0.999. The batch-to-batch reproducibility of a set of dosimeters after a single irradiation was found to be 3% (1 SD). The reproducibility of individual dosimeters was found to be 1.7%. No measurable angular dependence was found (results agreed within 1%). Dose rate response was found to agree within 1% for dose rates of 100 to 600 cGy/min. These results demonstrate the potential use of glass beads as TL dosimeters over the dose range commonly applied in radiotherapy. - Highlights: • We examined the dosimetric properties of a low cost commercially produced glass seed beads. • Glass beads are available in small size of 1–3 mm, suitable for dosimetry of small radiation fields. • The results demonstrate a mean reproducibility of 0.23% (2 SD), batch homogeneity of within 5%. • Dose response was linear over wide dose range tested for 1 cGy to kGy. • Improved fading effect of 10

  17. Evaluation of the Effect of Psyllium on the Viability of Lactobacillus Acidophilus in Alginate-Polyl Lysine Beads.

    Science.gov (United States)

    Esmaeilzadeh, Jaleh; Nazemiyeh, Hossein; Maghsoodi, Maryam; Lotfipour, Farzaneh

    2016-09-01

    Purpose: Psylliumseeds are used in traditional herbal medicine to treat various disorders. Moreover, as a soluble fiber, psyllium has potential to stimulate bacterial growth in digestive system. We aimed to substitute alkali-extractable polysaccharides of psyllium for alginate in beads with second coat of poly-l-lysine to coat Lactobacillus acidophilus. Methods: Beads were prepared using extrusion technique. Poly-l-lysine as second coat was incorporated on optimum alginate/psyllium beads using immersion technique. Beads were characterized in terms of size, encapsulation efficiency, integrity and bacterial survival in harsh conditions. Results: Beads with narrow size distribution ranging from 1.85 ± 0.05 to 2.40 ± 0.18 mm with encapsulation efficiency higher than 96% were achieved. Psyllium concentrations in beads did not produce constant trend in bead sizes. Surface topography by SEM showed that substitution of psyllium enhanced integrity of obtained beads. Psyllium successfully protected the bacteria against acidic condition and lyophilization equal to alginate in the beads. Better survivability with beads of alginate/psyllium-poly-l-lysine was achieved with around 2 log rise in bacterial count in acid condition compared to the corresponding single coat beads. Conclusion: Alginate/psyllium (1:2) beads with narrow size distribution and high encapsulation efficiency of the bacteria have been achieved. Presence of psyllium produced a much smoother and integrated surface texture for the beads with sufficient protection of the bacteria against acidic condition as much as alginate. Considering the health benefits of psyllium and its prebiotic activity, psyllium can be beneficially replaced in part for alginate in probiotic coating.

  18. Antimony sorption properties of chitosan - nano TiO2 composite beads

    International Nuclear Information System (INIS)

    Nishad, Padala Abdul; Bhaskarapillai, Anupkumar; Velmurugan, Sankaralingam

    2015-01-01

    Routine decontamination campaigns of nuclear reactors are generally effective in removing various radionuclides such as cobalt, caesium, etc., and bring down the radiation field. However, during some of the decontamination campaigns, the radiation field at some surfaces was seen to have actually gone up. This was found to be due to lack of removal of antimony isotopes by the regular ion exchange resins used, which subsequently deposited over out of core surfaces leading to increased radiation field on those surfaces. Thus there exists a need for efficient antimony removal system. We have synthesised nano titania impregnated - epichlorohydrin crosslinked chitosan beads, which were found to have high sorption capacity for antimony. The beads, which were synthesised in formats suitable for large scale (column mode) applications, were shown to be effective sorbent of antimony in both +3 and +5 oxidation states. The sorbent exhibited complete removal of antimony from its aqueous solutions of concentration ranging from 150 ppb to 120 ppm. In order to understand the sorption mechanism and to fine tune the bead composition, the effect of crosslinker concentration used during the synthesis on the swelling and sorption properties of the beads was investigated in detail. The variation effected significant changes in physical parameters such as bead diameter, swelling ratio, equilibrium water content and true wet density. Sorption capacity, unlike with regular resins, was found to increase with increase in crosslinker amount. The antimony sorption capacity of the crosslinked beads prepared by crosslinking 0.3 g uncrosslinked beads with 6.4 mmol epichlorohydrin (crosslinker) was 493 μmol/g. Non-crosslinked beads showed a capacity of 75 μmol/g, while the crosslinked beads made with the least amount of crosslinker (0.64 mmol per 0.3 g beads) showed a capacity of 133 μmol/g. These results indicate the possible involvement of the crosslinker in the sorption. (author)

  19. Impact of ultrasonication time on elution of super heavy oil and its biomarkers from aging soils using a Triton X-100 micellar solution

    International Nuclear Information System (INIS)

    Ji Guodong; Zhou Guohui

    2010-01-01

    An ultrasound-enhanced elution system with Triton X-100 solution was used to remediate aging soils contaminated with super heavy oil. We used GC/MS, SEM, and X-ray diffraction (XRD) to analyze the effect of ultrasonic time (0-1800 s) on the elution of super heavy oil and its three characteristic biomarkers (C 26-34 17α 25-norhopanes, C 26-28 triaromatic steroid [TAS], and C 27-29 methyl triaromatic steroid [MTAS]). The oil and biomarkers remaining in the treated soils followed similar second-order functions with increasing ultrasonication times. Biomarker elution was closely related to carbon numbers in the marker. For C 26-34 17α 25-norhopanes, the smaller molecules were more readily eluted during 0-360 s ultrasound. This trend was reversed upon application of ultrasound during 1080-1800 s, with improved elution of larger molecules and elution followed a similar second-order function. For C 26-28 TAS, smaller molecules were more readily eluted but the elution of larger molecules followed a similar second-order function. For C 27-29 MTAS, elution of larger molecules was close to that of C 26-34 17α 25-norhopanes. Results of SEM and XRD indicated that the mineral and chemical compositions of soils eluted at ultrasonication times of 1080-1800 s closely resembled clean soils.

  20. Optimization of Drug Delivery by Drug-Eluting Stents.

    Directory of Open Access Journals (Sweden)

    Franz Bozsak

    Full Text Available Drug-eluting stents (DES, which release anti-proliferative drugs into the arterial wall in a controlled manner, have drastically reduced the rate of in-stent restenosis and revolutionized the treatment of atherosclerosis. However, late stent thrombosis remains a safety concern in DES, mainly due to delayed healing of the endothelial wound inflicted during DES implantation. We present a framework to optimize DES design such that restenosis is inhibited without affecting the endothelial healing process. To this end, we have developed a computational model of fluid flow and drug transport in stented arteries and have used this model to establish a metric for quantifying DES performance. The model takes into account the multi-layered structure of the arterial wall and incorporates a reversible binding model to describe drug interaction with the cells of the arterial wall. The model is coupled to a novel optimization algorithm that allows identification of optimal DES designs. We show that optimizing the period of drug release from DES and the initial drug concentration within the coating has a drastic effect on DES performance. Paclitaxel-eluting stents perform optimally by releasing their drug either very rapidly (within a few hours or very slowly (over periods of several months up to one year at concentrations considerably lower than current DES. In contrast, sirolimus-eluting stents perform optimally only when drug release is slow. The results offer explanations for recent trends in the development of DES and demonstrate the potential for large improvements in DES design relative to the current state of commercial devices.

  1. Molecularly imprinted polymer beads for nicotine recognition prepared by RAFT precipitation polymerization: a step forward towards multifunctionalities

    DEFF Research Database (Denmark)

    Zhou, Tongchang; Jørgensen, Lars; Mattebjerg, Maria Ahlm

    2014-01-01

    A nicotine imprinted polymer was synthesized by reversible addition-fragmentation chain transfer (RAFT) polymerization using methacrylic acid (MAA) as a functional monomer. The resulting molecularly imprinted polymers were monodispersed beads with an average diameter of 1.55 mm. The molecular...... selectivity of the imprinted polymer beads was evaluated by studying the uptake of nicotine and its structural analogs by the polymer beads. Equilibrium binding results indicate that the amount of nicotine bound to the imprinted polymer beads is significantly higher than that bound to the nonimprinted polymer...

  2. Pulsed laser manipulation of an optically trapped bead: Averaging thermal noise and measuring the pulsed force amplitude

    DEFF Research Database (Denmark)

    Lindballe, Thue Bjerring; Kristensen, Martin V. G.; Keiding, Søren Rud

    2013-01-01

    An experimental strategy for post-eliminating thermal noise on position measurements of optically trapped particles is presented. Using a nanosecond pulsed laser, synchronized to the detection system, to exert a periodic driving force on an optically trapped 10 polystyrene bead, the laser pulse-bead...... interaction is repeated hundreds of times. Traces with the bead position following the prompt displacement from equilibrium, induced by each laser pulse, are averaged and reveal the underlying deterministic motion of the bead, which is not visible in a single trace due to thermal noise. The motion of the bead...... is analyzed from the direct time-dependent position measurements and from the power spectrum. The results show that the bead is on average displaced 208 nm from the trap center and exposed to a force amplitude of 71 nanoNewton, more than five orders of magnitude larger than the trapping forces. Our...

  3. New approaches to the preparation of PαMS beads as mandrels for NIF-scale target capsules

    International Nuclear Information System (INIS)

    Cook, R.; Buckley, S.R.; Fearon, E.; Letts, S.A.

    1999-01-01

    The authors report on a new method using heated density gradient columns for preparing spherical poly(αmethylstyrene) (PαMS) bead mandrels for inertial confinement fusion spherical shell targets. Using 1,2 propane diol/glycerol mixtures, stable density gradient columns for supporting PαMS beads can be prepared at temperatures as high as 150 C. At these temperatures plasticized commercial beads become fluid and spherical, however loss of the plasticizer and very low molecular weight components of the bead due to limited solubility in the column fluid leads to surface finish problems. The authors also present results on PαMS beads prepared in an aqueous bath batch mode. Using these techniques beads with maximum out-of-rounds less than 5 microm have been produced

  4. Studies of post-elution concentration of 99m-Tc eluted from a gel type chromatographic generator

    International Nuclear Information System (INIS)

    Suzuki, Katia N.; Osso Junior, Joao Alberto

    2007-01-01

    The radiopharmaceuticals most used in Diagnostic Nuclear Medicine are those labeled with the metastable technetium ( 99m Tc) due to its ideal physical properties of decay (t 1/2 6.01 h, Eγ 140 keV), low cost and availability facilitated through the commercial generator 99 Mo / 99m Tc. This radionuclide is formed by the β - decay of 99 Mo adsorbed on an alumina column of the generator and collected in the form of sodium pertechnetate (Na 99m TcO 4 ) by elution with saline solution (0.9%). The Radiopharmacy Center (CR) of the IPEN-CNEN/SP developed a gel type chromatographic generator of MoZr with 99 Mo produced by 98 Mo(n, γ) 99 Mo reaction that occurs in IEA-R1 Nuclear Reactor. The gel is composed of zirconium molybdate with elution volume of 12 ml with an activity of 11100 MBq (300 mCi) producing a radioactive concentration of 925 MBq (34 mCi) / ml. The fission generator gives a higher radioactive concentration around 1850 MBq (69 mCi) / ml. The aim of this work is to study a system of post-elution concentration using ion exchange cartridges in tandem (cation - anion) for the attainment of a high enough radioactive concentration to meet the demand of market, with a proved quality. This system of concentration will be made based in the technique of solid phase extraction (SPE) using commercial cartridges of extraction, which contains the solid phase and eluent saline solution (0.9%). As the eluent results of this system used in the gel generator of MoZr will be compared with the fission generator currently produced by IPEN-CNEN/SP. (author)

  5. Studies of post-elution concentration of {sup 99m}-Tc eluted from a gel type chromatographic generator

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Katia N.; Osso Junior, Joao Alberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: norisuzuki6@yahoo.com.br; jaosso@ipen.br

    2007-07-01

    The radiopharmaceuticals most used in Diagnostic Nuclear Medicine are those labeled with the metastable technetium ({sup 99m}Tc) due to its ideal physical properties of decay (t{sub 1/2} 6.01 h, E{gamma} 140 keV), low cost and availability facilitated through the commercial generator {sup 99}Mo /{sup 99m}Tc. This radionuclide is formed by the {beta}{sup -} decay of {sup 99}Mo adsorbed on an alumina column of the generator and collected in the form of sodium pertechnetate (Na{sup 99m}TcO{sub 4}) by elution with saline solution (0.9%). The Radiopharmacy Center (CR) of the IPEN-CNEN/SP developed a gel type chromatographic generator of MoZr with {sup 99}Mo produced by {sup 98}Mo(n, {gamma}){sup 99}Mo reaction that occurs in IEA-R1 Nuclear Reactor. The gel is composed of zirconium molybdate with elution volume of 12 ml with an activity of 11100 MBq (300 mCi) producing a radioactive concentration of 925 MBq (34 mCi) / ml. The fission generator gives a higher radioactive concentration around 1850 MBq (69 mCi) / ml. The aim of this work is to study a system of post-elution concentration using ion exchange cartridges in tandem (cation - anion) for the attainment of a high enough radioactive concentration to meet the demand of market, with a proved quality. This system of concentration will be made based in the technique of solid phase extraction (SPE) using commercial cartridges of extraction, which contains the solid phase and eluent saline solution (0.9%). As the eluent results of this system used in the gel generator of MoZr will be compared with the fission generator currently produced by IPEN-CNEN/SP. (author)

  6. Safety and efficacy of limus-eluting stents and balloon angioplasty for sirolimus-eluting in-stent restenosis

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Hideaki [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Mahmoudi, Michael [University of Surrey, Guildford Road, Surrey, GU2-7XH (United Kingdom); Kitabata, Hironori; Torguson, Rebecca; Chen, Fang; Satler, Lowell F.; Suddath, William O.; Pichard, Augusto D. [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States); Waksman, Ron, E-mail: ron.waksman@medstar.net [Division of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC 20010 (United States)

    2015-03-15

    Objectives: The aim of this study was to compare the safety and efficacy of everolimus-eluting stent (EES), sirolimus-eluting stent (SES), and plain old balloon angioplasty (POBA) for the treatment of SES in-stent restenosis (S-ISR). Background: The optimal treatment for drug-eluting in-stent restenosis remains controversial. Methods: The study cohort comprised 310 consecutive patients (444 lesions) who presented with S-ISR to our institution and underwent treatment with EES (43 patients), SES (102), or POBA (165). The analyzed clinical parameters were the 1-year rates of death, Q-wave myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), definite stent thrombosis (ST) and major adverse cardiac event (MACE) defined as the composite of death, MI, or TLR at 1-year. Results: The three groups were well matched for the conventional risk factors for coronary artery disease except for smoking. The 1-year analyzed clinical parameters were similar in the three groups: MACE (EES = 14%, SES = 18%, POBA = 20%; p = 0.65), death (EES = 2.3%, SES = 6.2%, POBA = 6.1%; p = 0.61), MI (EES = 4.8%, SES = 2.1%, POBA = 2.5%; p = 0.69), TLR (EES = 11.9%, SES = 12.1%, POBA = 24%; p = 0.78), and TVR (EES = 11.9%, SES = 24.8%, POBA = 22.2%; p = 0.23). There were no cases of definite ST. MACE-free rate was significantly lower in patients with recurrent in-stent restenosis (log-rank p = 0.006). Presentation with acute MI, number of treated lesions and a previous history of MI were found to be independent predictors of MACE. Conclusions: In patients presenting with S-ISR, treatment with implantation of an EES, SES, or POBA is associated with similar clinical outcomes. Patients presenting with recurrent ISR may have a poorer clinical outcome.

  7. Gradient elution behavior of proteins in hydrophobic interaction chromatography with U-shaped retention factor curves.

    Science.gov (United States)

    Creasy, Arch; Lomino, Joseph; Barker, Gregory; Khetan, Anurag; Carta, Giorgio

    2018-04-27

    Protein retention in hydrophobic interaction chromatography is described by the solvophobic theory as a function of the kosmostropic salt concentration. In general, an increase in salt concentration drives protein partitioning to the hydrophobic surface while a decrease reduces it. In some cases, however, protein retention also increases at low salt concentrations resulting in a U-shaped retention factor curve. During gradient elution the salt concentration is gradually decreased from a high value thereby reducing the retention factor and increasing the protein chromatographic velocity. For these conditions, a steep gradient can overtake the protein in the column, causing it to rebind. Two dynamic models, one based on the local equilibrium theory and the other based on the linear driving force approximation, are presented. We show that the normalized gradient slope determines whether the protein elutes in the gradient, partially elutes, or is trapped in the column. Experimental results are presented for two different monoclonal antibodies and for lysozyme on Capto Phenyl (High Sub) resin. One of the mAbs and lysozyme exhibit U-shaped retention factor curves and for each, we determine the critical gradient slope beyond which 100% recovery is no longer possible. Elution with a reverse gradient is also demonstrated at low salt concentrations for these proteins. Understanding this behavior has implications in the design of gradient elution since the gradient slope impacts protein recovery. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Optimization of elution salt concentration in stepwise elution of protein chromatography using linear gradient elution data. Reducing residual protein A by cation-exchange chromatography in monoclonal antibody purification.

    Science.gov (United States)

    Ishihara, Takashi; Kadoya, Toshihiko; Endo, Naomi; Yamamoto, Shuichi

    2006-05-05

    Our simple method for optimization of the elution salt concentration in stepwise elution was applied to the actual protein separation system, which involves several difficulties such as detection of the target. As a model separation system, reducing residual protein A by cation-exchange chromatography in human monoclonal antibody (hMab) purification was chosen. We carried out linear gradient elution experiments and obtained the data for the peak salt concentration of hMab and residual protein A, respectively. An enzyme-linked immunosorbent assay was applied to the measurement of the residual protein A. From these data, we calculated the distribution coefficient of the hMab and the residual protein A as a function of salt concentration. The optimal salt concentration of stepwise elution to reduce the residual protein A from the hMab was determined based on the relationship between the distribution coefficient and the salt concentration. Using the optimized condition, we successfully performed the separation, resulting in high recovery of hMab and the elimination of residual protein A.

  9. Development of a novel colorimetric sensor based on alginate beads for monitoring rainbow trout spoilage.

    Science.gov (United States)

    Majdinasab, Marjan; Hosseini, Seyed Mohammad Hashem; Sepidname, Marziyeh; Negahdarifar, Manizheh; Li, Peiwu

    2018-05-01

    Alginate is a non-toxic, renewable, and linear copolymer obtained from the brown algae Laminaria digitata that can be easily shaped into beads. Its good gel forming properties have made it useful for entrapping food and pharmaceutical ingredients. In this study, alginate beads were used in a novel application as a colorimetric sensor in food intelligent packaging. Colorimetric sensor was developed through entrapping red cabbage extract as a pH indicator in alginate beads. The pH indicator beads were used in rainbow trout packaging for monitoring fillets spoilage. Color change of beads during fish storage was measured using the CIELab method. The alginate bead colorimetric sensor is validated by measuring total volatile basic nitrogen (TVB-N) levels and microbial populations in fish samples. Moreover, peroxide value (PV) and thiobarbituric acid reactive substances (TBARS) were evaluated during storage. Results indicated that increasing the bacterial population during storage and production of proteolytic enzymes resulted in protein degradation, accumulation of volatile amine compounds, increase in the pH and finally color change of alginate beads. The values of TVB-N, pH, PV and TBARS increased with time of storage. The results of TVB-N and microbial growth were in accordance with color change of beads and CIELab data. Therefore, the proposed system enjoys a high sensitivity to pH variations and is capable of monitoring the spoilage of fish or other protein-rich products through its wide range of color changes. The alginate beads containing the red cabbage extract can, thus, be used as a low-cost colorimetric sensor for intelligent packaging applications.

  10. Observation of self-assembled fluorescent beads by scanning near-field optical microscopy and atomic force microscopy

    International Nuclear Information System (INIS)

    Oh, Y.J.; Jo, W.; Kim, Min-Gon; Kyu Park, Hyun; Hyun Chung, Bong

    2006-01-01

    Optical response and topography of fluorescent latex beads both on flat self-assembled monolayer and on a micron-patterned surface with poly(dimethylsiloxane) are studied. Scanning near-field optical microscopy and atomic force microscopy were utilized together for detecting fluorescence and imaging topography of the patterned latex beads, respectively. As a result, the micro-patterned latex beads where a specific chemical binding occurred show a strong signal, whereas no signals are observed in the case of nonspecific binding. With fluorescein isothiocyanate (FITC), it is convenient to measure fluorescence signal from the patterned beads allowing us to monitor the small balls of fluorescent latex

  11. In vitro evaluation of chitosan coated- and uncoated-calcium alginate beads containing methyl salicylate-lactose physical mixture.

    Science.gov (United States)

    Tamilvanan, S; Karmegam, S

    2012-01-01

    Methyl salicylate-lactose physical mixture (1:1 and 1:1.5 ratios) was incorporated into calcium alginate beads by a coacervation method involving an ionotropic gelation/polyelectrolyte complexation approach. This study aims to determine the influence of chitosan coating over the beads on drug entrapment efficiency (DEE) and release characteristics in artificial saliva compared to that of the uncoated beads. Changes in formulation parameters (gelation time, concentrations of Ca(2+) and alginate) resulted in decrease in DEE of chitosan-uncoated beads (p methyl salicylate-lactose physical mixture.

  12. Analysis of surface properties of fixed and live cells using derivatized agarose beads.

    Science.gov (United States)

    Navarro, Vanessa M; Walker, Sherri L; Badali, Oliver; Abundis, Maria I; Ngo, Lylla L; Weerasinghe, Gayani; Barajas, Marcela; Zem, Gregory; Oppenheimer, Steven B

    2002-01-01

    A novel assay has been developed for the histochemical characterization of surface properties of cells based on their adhesion to agarose beads derivatized with more than 100 types of molecules, including sugars, lectins and other proteins, and amino acids. The assay simply involves mixing small quantities of washed cells and beads in droplets on glass microscope slides and determining to which beads various cell types adhere. Distilled water was found to be the best medium for this assay because added ions or molecules in other media inhibit adhesion in some cases. Many cells, however, cannot tolerate distilled water. Here we show that cells fixed with either of two fixatives (1% formaldehyde or Prefer fixative) displayed similar bead-binding properties as did live cells. Specificity of cell-bead binding was tested by including specific free molecules in the test suspensions in hapten-type inhibition experiments. If a hapten compound inhibited live-cell adhesion to a specific bead, it also inhibited fixed-cell adhesion to a specific bead. The results of these experiments suggest that fixed cells display authentic surface properties, opening the door for the use of this assay with many cell types that cannot tolerate distilled water.

  13. Wax-incorporated emulsion gel beads of calcium pectinate for intragastric floating drug delivery.

    Science.gov (United States)

    Sriamornsak, Pornsak; Asavapichayont, Panida; Nunthanid, Jurairat; Luangtana-Anan, Manee; Limmatvapirat, Sontaya; Piriyaprasarth, Suchada

    2008-01-01

    The purpose of this study was to prepare wax-incorporated pectin-based emulsion gel beads using a modified emulsion-gelation method. The waxes in pectin-olive oil mixtures containing a model drug, metronidazole, were hot-melted, homogenized and then extruded into calcium chloride solution. The beads formed were separated, washed with distilled water and dried for 12 h. The influence of various types and amounts of wax on floating and drug release behavior of emulsion gel beads of calcium pectinate was investigated. The drug-loaded gel beads were found to float on simulated gastric fluid if the sufficient amount of oil was used. Incorporation of wax into the emulsion gel beads affected the drug release. Water-soluble wax (i.e. polyethylene glycol) increased the drug release while other water-insoluble waxes (i.e. glyceryl monostearate, stearyl alcohol, carnauba wax, spermaceti wax and white wax) significantly retarded the drug release. Different waxes had a slight effect on the drug release. However, the increased amount of incorporated wax in the formulations significantly sustained the drug release while the beads remained floating. The results suggest that wax-incorporated emulsion gel beads could be used as a carrier for intragastric floating drug delivery.

  14. REVIEW: CHITOSAN BASED HYDROGEL POLYMERIC BEADS – AS DRUG DELIVERY SYSTEM

    Directory of Open Access Journals (Sweden)

    Manjusha Rani

    2010-11-01

    Full Text Available Chitosan obtained by alkaline deacetylation of chitin is a non-toxic, biocompatible, and biodegradable natural polymer. Chitosan-based hydrogel polymeric beads have been extensively studied as micro- or nano-particulate carriers in the pharmaceutical and medical fields, where they have shown promise for drug delivery as a result of their controlled and sustained release properties, as well as biocompatibility with tissue and cells. To introduce desired properties and enlarge the scope of the potential applications of chitosan, graft copolymerization with natural or synthetic polymers on it has been carried out, and also, various chitosan derivatives have been utilized to form beads. The desired kinetics, duration, and rate of drug release up to therapeutical level from polymeric beads are limited by specific conditions such as beads material and their composition, bead preparation method, amount of drug loading, drug solubility, and drug polymer interaction. The present review summarizes most of the available reports about compositional and structural effects of chitosan-based hydrogel polymeric beads on swelling, drug loading, and releasing properties. From the studies reviewed it is concluded that chitosan-based hydrogel polymeric beads are promising drug delivery systems.

  15. Magnetic composite beads for sorption of cesium ions from aqueous streams

    International Nuclear Information System (INIS)

    Shinde, Rakesh N.; Pandey, A.K.; Acharya, R.; Rajurkar, N.S.

    2014-01-01

    Magnetic separation of metal ions is one of the promising methods due to simple, fast, efficient and cost effective technology. Highly selective magnetic sorbents can be designed by immobilizing functional groups in magnetic carrier which binds to the target specific ions. In the present work chitosan-(3-aminopropyl) triethoxysilane (APTS)- copperferrocyanide (CFC) composite beads have been synthesized for sorption of 137 Cs ions from aqueous streams. Physical characterization of the best resulted polymer beads was carried out by SEM-EDX and VSM technique. Sorption of Cs ions in the various magnetic polymer beads were studied in different aqueous condition by 137 Cs (662 KeV) radiotracer assay

  16. Advantages and disadvantages of biodegradable platforms in drug eluting stents.

    Science.gov (United States)

    Rodriguez-Granillo, Agustina; Rubilar, Bibiana; Rodriguez-Granillo, Gaston; Rodriguez, Alfredo E

    2011-03-26

    Coronary angioplasty with drug-eluting stent (DES) implantation is currently the most common stent procedure worldwide. Since the introduction of DES, coronary restenosis as well as the incidence of target vessel and target lesion revascularization have been significantly reduced. However, the incidence of very late stent thrombosis beyond the first year after stent deployment has more commonly been linked to DES than to bare-metal stent (BMS) implantation. Several factors have been associated with very late stent thrombosis after DES implantation, such as delayed healing, inflammation, stent mal-apposition and endothelial dysfunction. Some of these adverse events were associated with the presence of durable polymers, which were essential to allow the elution of the immunosuppressive drug in the first DES designs. The introduction of erodable polymers in DES technology has provided the potential to complete the degradation of the polymer simultaneously or immediately after the release of the immunosuppressive drug, after which a BMS remains in place. Several DES designs with biodegradable (BIO) polymers have been introduced in preclinical and clinical studies, including randomized trials. In this review, we analyze the clinical results from 6 observational and randomized studies with BIO polymers and discuss advantages and disadvantages of this new technology.

  17. Dynamics of silver elution from functionalised antimicrobial nanofiltration membranes.

    Science.gov (United States)

    Choudhari, S; Habimana, O; Hannon, J; Allen, A; Cummins, E; Casey, E

    2017-07-01

    In an effort to mitigate biofouling on thin film composite membranes such as nanofiltration and reverse osmosis, a myriad of different surface modification strategies has been published. The use of silver nanoparticles (Ag-NPs) has emerged as being particularly promising. Nevertheless, the stability of these surface modifications is still poorly understood, particularly under permeate flux conditions. Leaching or elution of Ag-NPs from the membrane surface can not only affect the antimicrobial characteristics of the membrane, but could also potentially present an environmental liability when applied in industrial-scale systems. This study sought to investigate the dynamics of silver elution and the bactericidal effect of an Ag-NP functionalised NF270 membrane. Inductively coupled plasma-atomic emission spectroscopy was used to show that the bulk of leached silver occurred at the start of experimental runs, and was found to be independent of salt or permeate conditions used. Cumulative amounts of leached silver did, however, stabilise following the initial release, and were shown to have maintained the biocidal characteristics of the modified membrane, as observed by a higher fraction of structurally damaged Pseudomonas fluorescens cells. These results highlight the need to comprehensively assess the time-dependent nature of bactericidal membranes.

  18. Preparation of ionic-crosslinked chitosan-based gel beads and effect of reaction conditions on drug release behaviors.

    Science.gov (United States)

    Chen, Shilan; Liu, Mingzhu; Jin, Shuping; Wang, Bin

    2008-02-12

    Drug-loaded chitosan (CS) beads were prepared under simple and mild condition using trisodium citrate as ionic crosslinker. The beads were further coated with poly(methacrylic acid) (PMAA) by dipping the beads in PMAA aqueous solution. The surface and cross-section morphology of these beads were observed by scanning electron microscopy and the observation showed that the coating beads had core-shell structure. In vitro release of model drug from these beads obtained under different reaction conditions was investigated in buffer medium (pH 1.8). The results showed that the rapid drug release was restrained by PMAA coating and the optimum conditions for preparing CS-based drug-loaded beads were decided through the effect of reaction conditions on the drug release behaviors. In addition, the drug release mechanism of CS-based drug-loaded beads was analyzed by Peppa's potential equation. According to this study, the ionic-crosslinked CS beads coated by PMAA could serve as suitable candidate for drug site-specific carrier in stomach.

  19. Decolourisation of dyes under electro-Fenton process using Fe alginate gel beads

    Energy Technology Data Exchange (ETDEWEB)

    Rosales, E.; Iglesias, O.; Pazos, M. [Department of Chemical Engineering, University of Vigo, Isaac Newton Building, Campus As Lagoas, Marcosende 36310, Vigo (Spain); Sanroman, M.A., E-mail: sanroman@uvigo.es [Department of Chemical Engineering, University of Vigo, Isaac Newton Building, Campus As Lagoas, Marcosende 36310, Vigo (Spain)

    2012-04-30

    Highlights: Black-Right-Pointing-Pointer Catalytic activity of Fe alginate gel beads for the remediation of wastewater was tested. Black-Right-Pointing-Pointer New electro-Fenton process for the remediation of polluted wastewater. Black-Right-Pointing-Pointer Continuous dye treatment without operational problem with high removal. - Abstract: This study focuses on the application of electro-Fenton technique by use of catalytic activity of Fe alginate gel beads for the remediation of wastewater contaminated with synthetic dyes. The Fe alginate gel beads were evaluated for decolourisation of two typical dyes, Lissamine Green B and Azure B under electro-Fenton process. After characterization of Fe alginate gel beads, the pH effect on the process with Fe alginate beads and a comparative study of the electro-Fenton process with free Fe and Fe alginate bead was done. The results showed that the use of Fe alginate beads increases the efficiency of the process; moreover the developed particles show a physical integrity in a wide range of pH (2-8). Around 98-100% of dye decolourisation was obtained for both dyes by electro-Fenton process in successive batches. Therefore, the process was performed with Fe alginate beads in a bubble continuous reactor. High color removal (87-98%) was attained for both dyes operating at a residence time of 30 min, without operational problems and maintaining particle shapes throughout the oxidation process. Consequently, the stable performance of Fe alginate beads opens promising perspectives for fast and economical treatment of wastewater polluted by dyes or similar organic contaminants.

  20. Decolourisation of dyes under electro-Fenton process using Fe alginate gel beads

    International Nuclear Information System (INIS)

    Rosales, E.; Iglesias, O.; Pazos, M.; Sanromán, M.A.

    2012-01-01

    Highlights: ► Catalytic activity of Fe alginate gel beads for the remediation of wastewater was tested. ► New electro-Fenton process for the remediation of polluted wastewater. ► Continuous dye treatment without operational problem with high removal. - Abstract: This study focuses on the application of electro-Fenton technique by use of catalytic activity of Fe alginate gel beads for the remediation of wastewater contaminated with synthetic dyes. The Fe alginate gel beads were evaluated for decolourisation of two typical dyes, Lissamine Green B and Azure B under electro-Fenton process. After characterization of Fe alginate gel beads, the pH effect on the process with Fe alginate beads and a comparative study of the electro-Fenton process with free Fe and Fe alginate bead was done. The results showed that the use of Fe alginate beads increases the efficiency of the process; moreover the developed particles show a physical integrity in a wide range of pH (2–8). Around 98–100% of dye decolourisation was obtained for both dyes by electro-Fenton process in successive batches. Therefore, the process was performed with Fe alginate beads in a bubble continuous reactor. High color removal (87–98%) was attained for both dyes operating at a residence time of 30 min, without operational problems and maintaining particle shapes throughout the oxidation process. Consequently, the stable performance of Fe alginate beads opens promising perspectives for fast and economical treatment of wastewater polluted by dyes or similar organic contaminants.

  1. EXPERIMENTAL TESTING OF DRAW—BEAD RESTRAINING FORCE IN SHEET METAL FORMING

    Institute of Scientific and Technical Information of China (English)

    J.H.Yang; J.Chen; 等

    2003-01-01

    Due to complexities of draw-bead restraining force calculated according to theory and depending on sheet metal forming properties experiment testing system,a simplified method to calculate draw-bead restraining force is put forward by experimental method in cup-shaped drawing process.The experimental results were compared with numer-ical results and proved agreement.It shows the method is effective.

  2. Long-term outcome in patients treated with sirolimus-eluting stents in complex coronary artery lesions: 3-year results of the SCANDSTENT (Stenting Coronary Arteries in Non-Stress/Benestent Disease) trial

    DEFF Research Database (Denmark)

    Kelbaek, H.; Klovgaard, L.; Helqvist, S.

    2008-01-01

    data of the long-term outcome of patients with complex coronary artery lesions. METHODS: We randomly assigned 322 patients with total coronary occlusions or lesions located in bifurcations, ostial, or angulated segments of the coronary arteries to have SES or BMS implanted. RESULTS: At 3 years, major...... performed between 1 and 3 years after the index treatment (p = NS). According to revised definitions, stent thrombosis occurred in 5 patients (3.1%) in the SES group and in 7 patients (4.4%) in the BMS group (p = NS); very late stent thrombosis was observed in 4 versus 1 patient. CONCLUSIONS: A continued...

  3. The Beads of Translation: Using Beads to Translate mRNA into a Polypeptide Bracelet

    Science.gov (United States)

    Dunlap, Dacey; Patrick, Patricia

    2012-01-01

    During this activity, by making beaded bracelets that represent the steps of translation, students simulate the creation of an amino acid chain. They are given an mRNA sequence that they translate into a corresponding polypeptide chain (beads). This activity focuses on the events and sites of translation. The activity provides students with a…

  4. Development and validation of predictive simulation model of multi-layer repair welding process by temper bead technique

    International Nuclear Information System (INIS)

    Okano, Shigetaka; Miyasaka, Fumikazu; Mochizuki, Masahito; Tanaka, Manabu

    2015-01-01

    Stress corrosion cracking (SCC) has recently been observed in the nickel base alloy weld metal of dissimilar pipe joint used in pressurized water reactor (PWR) . Temper bead technique has been developed as one of repair procedures against SCC applicable in case that post weld heat treatment (PWHT) is difficult to carry out. In this regard, however it is essential to pass the property and performance qualification test to confirm the effect of tempering on the mechanical properties at repair welds before temper bead technique is actually used in practice. Thus the appropriate welding procedure conditions in temper bead technique are determined on the basis of the property and performance qualification testing. It is necessary for certifying the structural soundness and reliability at repair welds but takes a lot of work and time in the present circumstances. Therefore it is desirable to establish the reasonable alternatives for qualifying the property and performance at repair welds. In this study, mathematical modeling and numerical simulation procedures were developed for predicting weld bead configuration and temperature distribution during multi-layer repair welding process by temper bead technique. In the developed simulation technique, characteristics of heat source in temper bead welding are calculated from weld heat input conditions through the arc plasma simulation and then weld bead configuration and temperature distribution during temper bead welding are calculated from characteristics of heat source obtained through the coupling analysis between bead surface shape and thermal conduction. The simulation results were compared with the experimental results under the same welding heat input conditions. As the results, the bead surface shape and temperature distribution, such as A cl lines, were in good agreement between simulation and experimental results. It was concluded that the developed simulation technique has the potential to become useful for

  5. Analysis of the role of elution buffers on the separation capabilities of dielectrophoretic devices

    Directory of Open Access Journals (Sweden)

    Rossana Di Martino

    2016-03-01

    Full Text Available Field flow fractionation dielectrophoretic (FFF-DEP devices are currently used, among the others, for the separation of tumor cells from healthy blood cells. To this end specific suspension/elution buffers (EBs, with reduced conductivity (with respect to that of the cell cytoplasm are generally used. In this paper we investigate the long-term alterations of the cells and elution buffers. We find that the EB conductivity is critically modified within few minutes after cells suspension. In turn, this modification results in a change the ideal separation frequency of the FFF-DEP device. On the other hand we prove that DEP manipulation is preserved for more than three hours for cells suspended in the considered EBs. Keywords: Dielectrophoresis, Elution buffer, Circulating tumor cells, Cell motility

  6. Analysis of platinum content in biodegradable carboplatin-impregnated beads and retrospective assessment of tolerability for intralesional use of the beads in dogs following excision of subcutaneous sarcomas: 29 cases (2011-2014).

    Science.gov (United States)

    Hess, Theresa A; Drinkhouse, Macy E; Prey, Joshua D; Miller, Jonathan M; Fettig, Arthur A; Carberry, Carol A; Brenn, Stephen H; Bailey, Dennis B

    2018-02-15

    OBJECTIVE To evaluate platinum content in biodegradable carboplatin-impregnated beads and retrospectively assess tolerability and outcome data for dogs treated by intralesional placement of such beads following surgical excision of subcutaneous sarcomas. DESIGN Evaluation study and retrospective case series. SAMPLE 9 carboplatin-impregnated beads and 29 client-owned dogs. PROCEDURES Platinum content in 9 carboplatin-impregnated beads from 3 lots was measured by spectrophotometry, and calculated carboplatin content was compared with the labeled content. Medical records were searched to identify dogs with subcutaneous sarcomas for which treatment included placement of carboplatin-impregnated beads between 2011 and 2014. Signalment, tumor characteristics, surgical and histologic data, adverse events, and local recurrences were recorded. Associations between variables of interest and adverse events or local disease-free interval were analyzed. RESULTS In vitro analysis identified a mean ± SD platinum content of 5.38 ± 0.97 mg/bead. Calculated carboplatin content (10.24 ± 1.84 mg/bead) was significantly greater than the labeled amount (4.6 mg/bead). Bead weight and total platinum content differed significantly among lots, but platinum content per bead weight did not. Mild-to-moderate local adverse events were reported for 11 of 29 tumors; all resolved without additional surgery. No dogs had signs of systemic toxicosis. Overall local disease-free rates 1, 2, and 3 years after surgery were 70%, 70%, and 58%, respectively, as determined by Kaplan-Meier analysis. CONCLUSIONS AND CLINICAL RELEVANCE Carboplatin-impregnated beads were well tolerated; however, results of in vitro tests indicated that caution is needed because of manufacturing inconsistencies.

  7. One-step isolation of plasma membrane proteins using magnetic beads with immobilized concanavalin A

    DEFF Research Database (Denmark)

    Lee, Yu-Chen; Block, Gregory; Chen, Huiwen

    2008-01-01

    We have developed a simple method for isolating and purifying plasma membrane proteins from various cell types. This one-step affinity-chromatography method uses the property of the lectin concanavalin A (ConA) and the technique of magnetic bead separation to obtain highly purified plasma membrane...... proteins from crude membrane preparations or cell lines. ConA is immobilized onto magnetic beads by binding biotinylated ConA to streptavidin magnetic beads. When these ConA magnetic beads were used to enrich plasma membranes from a crude membrane preparation, this procedure resulted in 3.7-fold enrichment...... of plasma membrane marker 5'-nucleotidase activity with 70% recovery of the activity in the crude membrane fraction of rat liver. In agreement with the results of 5'-nucleotidase activity, immunoblotting with antibodies specific for a rat liver plasma membrane protein, CEACAM1, indicated that CEACAM1...

  8. [Evaluation of TB-beads assay utilizing the technique of magnetic beads--an innovative assay method for detection of acid fast bacilli].

    Science.gov (United States)

    Ohkuma, Masanori; Ikeda, Katsuyoshi; Obayashi, Konen; Ando, Yukio; Koriyama, Toyoyasu; Kimu, Minhi; Hirose, Nobuyuki; Nagasawa, Zenzo; Miyamoto, Hiroshi

    2012-01-01

    The centrifuge method with the use of Semi-Alkalin Proteinase (SAP) and NALC-NaOH, recommended by the "2007 edition of the assay guideline for detection of Mycobacterium tuberculosis," has significantly contributed to improving the sensitivities and specificities of both smear and culture tests for detection of acid fast bacilli (AFB). However, this method poses some challenges in terms of its cumbersome and time-consuming assay protocol. "TB-beads (Kyokuto Pharmaceutical Industrial Co., Ltd.)" is a newly-developed method for detection of AFB utilizing magnetic beads. We evaluated the quality of this method in comparison with the centrifuge method, focusing on the results of smear and culture tests. This evaluation study was conducted using both 5 positive and 5 negative sputum samples. The sensitivity of TB-beads for fluorescent smear tests, conducted using "Acri-stain," was almost the same as that of the centrifuge method. One advantage of TB-beads, however, was that it was very convenient to practice microscopic observation due to the clear background of the smeared glass slides. The comparison of the contamination rates between the two methods showed that TB-beads suggested significantly lower contamination rates. The centrifuge method resulted in 50% and 60% of contamination rates for HK Semisolid Isolation Medium and BacT/ALERT MP, respectively. On the other hand, the contamination rates of TB-beads for both of the culture methods were only 10%. With regard to the 5 positive sputum samples, the comparison of the detection rates between the centrifuge and TB-Beads method was made utilizing Myco Acid, Ogawa K, and BacT/ALERT MP. The TB-Beads method suggested higher detection rates for Myco Acid and Ogawa K, while there were no significant differences between the two methods for BacT/ALERT MP (16-23 days). TB-beads is an easy method that allows to simplify the process of smear tests, and contributes to significantly reducing the contamination rate of culture

  9. Stent Coating Integrity of Durable and Biodegradable Coated Drug Eluting Stents.

    Science.gov (United States)

    Yazdani, Saami K; Sheehy, Alexander; Pacetti, Stephen; Rittlemeyer, Brandon; Kolodgie, Frank D; Virmani, Renu

    2016-10-01

    Coatings consisting of a polymer and drug are widely used in drug-eluting stents (DES) and are essential in providing programmable drug release kinetics. Among other factors, stent coating technologies can influence blood compatibility, affect acute and sub-acute healing, and potentially trigger a chronic inflammatory response. The aim of this study was to investigate the short-term (7 and 28 days) and long-term (90 and 180 days) coating integrity of the Xience Prime Everolimus-Eluting Stent (EES), Resolute Zotarolimus-Eluting Stent (ZES), Taxus Paclitaxel-Eluting Stent (PES), and Nobori Biolimus A9-Eluting Stent (BES) in a rabbit ilio-femoral stent model. Stented arteries (n = 48) were harvested and the tissue surrounding the implanted stents digested away with an enzymatic solution. Results demonstrated that the majority of struts of EES were without any coating defects with a few struts showing minor defects. Similarly, for the ZES, most of the struts were without coating defects at all time points except at 180 days. The majority of PES demonstrated mostly webbing and uneven coating. In the BES group, the majority of strut coating showed polymer cracking. Overall, the EES and ZES had fewer coating defects than the PES and BES. Coating defects, however increase over time for the ZES, whereas the percent of coating irregularities remained constant for the EES. These results provide, for the first time, a comparison of the long-term durability of these drug-eluting stent coatings in vivo. © 2016, Wiley Periodicals, Inc.

  10. Bead perturbation measurement for the KEK linac cavity

    International Nuclear Information System (INIS)

    Okumura, Shoji; Swenson, D.A.

    1975-03-01

    The axial electric field in the KEK linac cavity is measured by a bead perturbation method. The beat signal of around 1 kHz is generated with the rf signals from the cavity in self-excitation and from a signal generator whose output frequency is fixed. The period of the beat signal is measured by a counter in order to detect the small change in the resonant frequency of the cavity due to a bead perturbation. The counting data are transferred to a mini-computer after each period of the beat signal. The average fields of each gap are calculated in the computer and they are displayed on a storage oscilloscope. It takes about 50 seconds to complete the whole process of the measurement. The measuring system and the results obtained are described in this paper. (auth.)

  11. Hypotonic elution, a new desorption principle in immunoadsorbent chromatography

    DEFF Research Database (Denmark)

    Danielsen, Erik Michael; Sjöström, H; Norén, O

    1982-01-01

    of finding an efficient means of elution which is not denaturing to neither the purified enzyme nor the immunoadsorbent column. Common properties of the microvillar enzymes with regard to amphiphilicity, glycosylation or subunit composition could hypothetically account for the similar elution properties...

  12. Drug-eluting stents to prevent stent thrombosis and restenosis.

    Science.gov (United States)

    Im, Eui; Hong, Myeong-Ki

    2016-01-01

    Although first-generation drug-eluting stents (DES) have significantly reduced the risk of in-stent restenosis, they have also increased the long-term risk of stent thrombosis. This safety concern directly triggered the development of new generation DES, with innovations in stent platforms, polymers, and anti-proliferative drugs. Stent platform materials have evolved from stainless steel to cobalt or platinum-chromium alloys with an improved strut design. Drug-carrying polymers have become biocompatible or biodegradable and even polymer-free DES were introduced. New limus-family drugs (such as everolimus, zotarolimus or biolimus) were adopted to enhance stent performances. As a result, these new DES demonstrated superior vascular healing responses on intracoronary imaging studies and lower stent thrombotic events in actual patients. Recently, fully-bioresorbable stents (scaffolds) have been introduced, and expanding their applications. In this article, the important concepts and clinical results of new generation DES and bioresorbable scaffolds are described.

  13. Production of 99Tc generators with automatic elution

    International Nuclear Information System (INIS)

    Mengatti, J.; Yanagawa, S.T.I.; Mazzarro, E.; Gasiglia, H.T.; Rela, P.R.; Silva, C.P.G. da; Pereira, N.P.S. de.

    1983-10-01

    The improvements performed on the routine production of sup(99m) Tc-generators at the Instituto de Pesquisas Energeticas e Nucleares-CNEN/SP, are described. The old model generators (manual elution of sup(99m) Tc) were substituted by automatically eluted generators (Vacuum system). The alumina column, elution system and acessories were modified; the elution time was reduced from 60 to 20-30 seconds. The new generators give 80-90% elution yields using six mililiters of sodium chloride 0,9% as sup(99m) Tc eluant instead of the 10 mililiters necessary to eluate the old generators. So, the radioactive concentrations are now 70% higher. The radioactive, radiochemical, chemical and microbiological criteria were examinated for sup(99m) Tc solutions. Like old generators, automatic generators were considered safe for medical purpose. (Author) [pt

  14. Multiple dual mode counter-current chromatography with variable duration of alternating phase elution steps.

    Science.gov (United States)

    Kostanyan, Artak E; Erastov, Andrey A; Shishilov, Oleg N

    2014-06-20

    The multiple dual mode (MDM) counter-current chromatography separation processes consist of a succession of two isocratic counter-current steps and are characterized by the shuttle (forward and back) transport of the sample in chromatographic columns. In this paper, the improved MDM method based on variable duration of alternating phase elution steps has been developed and validated. The MDM separation processes with variable duration of phase elution steps are analyzed. Basing on the cell model, analytical solutions are developed for impulse and non-impulse sample loading at the beginning of the column. Using the analytical solutions, a calculation program is presented to facilitate the simulation of MDM with variable duration of phase elution steps, which can be used to select optimal process conditions for the separation of a given feed mixture. Two options of the MDM separation are analyzed: 1 - with one-step solute elution: the separation is conducted so, that the sample is transferred forward and back with upper and lower phases inside the column until the desired separation of the components is reached, and then each individual component elutes entirely within one step; 2 - with multi-step solute elution, when the fractions of individual components are collected in over several steps. It is demonstrated that proper selection of the duration of individual cycles (phase flow times) can greatly increase the separation efficiency of CCC columns. Experiments were carried out using model mixtures of compounds from the GUESSmix with solvent systems hexane/ethyl acetate/methanol/water. The experimental results are compared to the predictions of the theory. A good agreement between theory and experiment has been demonstrated. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Drug elution from high-dose antibiotic-loaded acrylic cement: a comparative, in vitro study.

    Science.gov (United States)

    Gasparini, Giorgio; De Gori, Marco; Calonego, Giovanni; Della Bora, Tommaso; Caroleo, Benedetto; Galasso, Olimpio

    2014-11-01

    High-dose antibiotic-loaded acrylic cement (ALAC) is used for managing peri-prosthetic joint infections (PJIs). The marked increase in resistant high-virulence bacteria is drawing the attention of physicians toward alternative antimicrobial formulations loaded into acrylic bone cement. The aim of this in vitro study was to determine the elution kinetics of 14 different high-dose ALACs. All ALAC samples showed a burst release of antibiotics in the first hour, progressively decreasing over time, and elution curves strictly adhered to a nonlinear regression analysis formula. Among aminoglycosides, commonly seen as the most appropriate antibiotics to be loaded into the bone cement, the highest elution rate was that of tobramycin. Among the glycopeptides, a class of antibiotics that should be considered to treat PJIs because of the prevalence of aminoglycoside resistance, vancomycin showed better elution than teicoplanin. Clindamycin, which can be associated with aminoglycosides to prepare ALACs and represents a useful option against the most common pathogens responsible for PJIs, showed the highest absolute and relative elutions among all the tested formulations. A noticeable elution was also detected for colistin, an antibiotic of last resort for treating multidrug-resistant bacteria. The current study demonstrates theoretical advantages in the preparation of ALAC for some antibiotics not routinely used in the clinical setting for PJIs. The use of these antibiotics based on the infecting bacteria sensitivity may represent a useful option for physicians to eradicate PJIs. In vivo testing should be considered in the future to confirm the results of this study. Copyright 2014, SLACK Incorporated.

  16. CUTANEOUS SQUAMOUS CELL CARCINOMA IN A PANTHER CHAMELEON (FURCIFER PARDALIS) AND TREATMENT WITH CARBOPLATIN IMPLANTABLE BEADS.

    Science.gov (United States)

    Johnson, James G; Naples, Lisa M; Chu, Caroline; Kinsel, Michael J; Flower, Jennifer E; Van Bonn, William G

    2016-09-01

    A 3-yr-old male panther chameleon (Furcifer pardalis) presented with bilateral raised crusted skin lesions along the lateral body wall that were found to be carcinoma in situ and squamous cell carcinoma. Similar lesions later developed on the caudal body wall and tail. A subcutaneous implantable carboplatin bead was placed in the first squamous cell carcinoma lesion identified. Additional new lesions sampled were also found to be squamous cell carcinomas, and viral polymerase chain reaction was negative for papillomaviruses and herpesviruses. Significant skin loss would have resulted from excision of all the lesions, so treatment with only carboplatin beads was used. No adverse effects were observed. Lesions not excised that were treated with beads decreased in size. This is the first description of cutaneous squamous cell carcinoma and treatment with carboplatin implantable beads in a panther chameleon.

  17. Investigation the influence of dietary fiber on the rheological properties of alginate beads

    Directory of Open Access Journals (Sweden)

    Z. Manev

    2015-03-01

    Full Text Available Abstract. During the current investigation experiments for the preparation of alginate beads with aqueous solutions of sodium alginate, calcium lactate or calcium dichloride and dietary fiber in different concentrations: inulin with varying degrees of polymerization, wheat bran and amidated apple pectin were carried out. The sodium alginate solutions were at constant concentration 3%, while calcium salts in 7% were applied for bead formation. It was proven that the rupture force of alginate beads was always higher than the pure model system regardless of the chemical structure of dietary fibers used. In the result of the carried research the dependence at a certain concentration was established at which the rupture force and deformation of the beads increased gradually.

  18. STUDY ON THE SYNTHESIS AND STRUCTURE OF MACRORETICULAR BEAD PAN/PVC IPN RESINS

    Institute of Scientific and Technical Information of China (English)

    LI Yanfeng; ZHUO Renxi

    1993-01-01

    Macroreticular bead PAN/PVC IPN reans with cyano and chloro groups were synthesized by interpenetrating polymerization of acrylonitrile, or acrylonitrile and divinylbenzene into a macroporous polyvinyl chloride bead. The composition and structure of the bead IPN resins have been investigated by means of FT-IR, NMR, SEM, mercury porosimetry and elemental analysis. During the process of interpenetrating polymerization, the chain propagation obeys Bernoullian statistical law, and no grafting polymerization has been observed. The content of cyano group in the resulting IPN resins can be adjusted by the amount of acrylonitrile added. The morphology of the IPN resins basically resembles that of the polyvinyl chloride bead,whereas the pore structures vary to a certain degree

  19. Rapid bead-based immunoassay for measurement of mannose-binding lectin

    DEFF Research Database (Denmark)

    Bay, J T; Garred, P

    2009-01-01

    have been developed more automated platforms for MBL analysis is urgently needed. To pursue this, we set out to develop a flexible bead-based MBL immunoassay. Serum was obtained from 98 healthy individuals and 50 patients investigated for possible immunodeficiencies. We used the Luminex xMAP bead array...... coefficient were found be 7.88% and 5.70%, respectively. A close correlation between the new assay and a reference MBL measurement ELISA was found (rho 0.9381, P bead-based assay was less sensitive to interfering anti-murine antibodies in the blood samples than when the antibodies employed were...... used in the reference polystyrene-based ELISA. The new assay could be performed in 3 h with less than 25 microl serum required of each sample. These results show that MBL can be measured readily using a bead-based platform, which may form an efficient basis for a multiplex approach to measure different...

  20. Tumour metastasis-associated gene profiling using one-dimensional microfluidic beads array

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Great efforts have been made on the early diagnosis and molecular mechanism research of tumour metastasis in recent years. In this paper, based on the one-dimensional microfluidic beads array, a novel platform for tumour metastasis-associated genes profiling has been developed by depositing nucleic acids functional beads in the microchannel. This platform is sensitive (limit of detection: 0.02 nmol/L) and can perform mRNAs analysis without PCR. Two human colon cancer cell lines (primary and metastatic) from the same patient were used as a model, and transcriptional expression profiling of multiple tumour metastasis-associated genes in these two cell lines was successfully achieved. Furthermore, the results obtained on the beads array were validated by RT-PCR. This novel beads array has advantages of high sensitivity, little sample consumption, short assay time, low cost and high throughput capability. It holds the potential in early diagnosis and mechanism research of tumour metastasis.

  1. Polyaniline coated magnetic carboxymethylcellulose beads for selective removal of uranium ions from aqueous solution

    International Nuclear Information System (INIS)

    Yakup Arica, M.; Gulay Bayramoglu; Gazi University, Ankara

    2016-01-01

    Magnetic carboxymethylcellulose (CMC) beads were prepared via ionic cross-linking. Then CMC beads were coated with polyaniline (PANI). The results of FTIR, SEM, DTA and N 2 adsorption-desorption demonstrated that aniline was successfully grafted onto the surface of mCMC beads. The potential use of the prepared adsorbent was used for removal of U(VI) ions. The determined maximum adsorption capacities of the mCMC and mCMC-g-PANI beads for U(VI) ions were 129.4 and 386.5 mg/g dry weight at pH 4.5, respectively. The thermodynamic parameters (ΔH°, ΔS° and ΔG°) were evaluated. The adsorbent systems were regenerated using 0.1 M HCl. (author)

  2. Effect of Welding Parameters on Dilution and Weld Bead Geometry in Cladding

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The effect of pulsed gas metal arc welding (GMAW) variables on the dilution and weld bead geometry in cladding X65 pipeline steel with 316L stainless steel was studied. Using a full factorial method, a series of experiments were carried out to know the effect of wire feed rate, welding speed, distance between gas nozzle and plate, and the vertical angle of welding on dilution and weld bead geometry. The findings indicate that the dilution of weld metal and its dimension i.e. width, height and depth increase with the feed rate, but the contact angle of the bead decreases first and then increases. Meantime, welding speed has an opposite effect except for dilution. There is an interaction effect between welding parameters at the contact angle. The results also show forehand welding or decreasing electrode extension decrease the angle of contact. Finally,a mathematical model is contrived to highlight the relationship between welding variables with dilution and weld bead geometry.

  3. Asynchronous Magnetic Bead Rotation (AMBR Microviscometer for Label-Free DNA Analysis

    Directory of Open Access Journals (Sweden)

    Yunzi Li

    2014-03-01

    Full Text Available We have developed a label-free viscosity-based DNA detection system, using paramagnetic beads as an asynchronous magnetic bead rotation (AMBR microviscometer. We have demonstrated experimentally that the bead rotation period is linearly proportional to the viscosity of a DNA solution surrounding the paramagnetic bead, as expected theoretically. Simple optical measurement of asynchronous microbead motion determines solution viscosity precisely in microscale volumes, thus allowing an estimate of DNA concentration or average fragment length. The response of the AMBR microviscometer yields reproducible measurement of DNA solutions, enzymatic digestion reactions, and PCR systems at template concentrations across a 5000-fold range. The results demonstrate the feasibility of viscosity-based DNA detection using AMBR in microscale aqueous volumes.

  4. Preparation of carbon nanotubes/epoxy resin composites by using hollow glass beads as the carrier

    International Nuclear Information System (INIS)

    Wu, X.F.; Zhao, Y.K.; Zhang, D.; Chen, T.B.; Ma, L.Y.

    2012-01-01

    Hollow glass beads had been utilized as the carrier to assist dispersion of carbon nanotubes in epoxy resin. Hollow glass beads were firstly aminated with gamma-aminopropyl-triethoxysilane, sencondly reacted with carboxyl-functionalized carbon nanotubes via an amidation reaction and susequently mixed with epoxy resin and hardener. The experimental results showed that carbon nanotubes could be loaded on the surfaces of hollow glass beads and approximately a monolayer of carbon nanotubes was formed when the weight ratio of hollow glass beads to carbon nanotubes was 100:5. Moreover, the dispersity of carbon nanotubes in the matrix was improved as compared to the control samples prepared by using a conventional mixing method. (author)

  5. Synthesis and characterization of chitosan impregnated calcium alginate beads for removal of uranium from aquatic stream

    International Nuclear Information System (INIS)

    Singhal, R.K.; Basu, H.; Manisha, V.; Reddy, A.V.R.; Sawant, Manjiri; Kamane, Suman

    2015-01-01

    The present study was conducted to study the feasibility of chitosan impregnated calcium alginate beads (Cal-Alg-Chi) to sorb the excess uranium from the aquatic stream. Chitosan is a linear polysaccharide composed of randomly distributed β-(1-4)-linked D glucosamine (deacetylated unit) and N-acetyl-D-glucosamine (acetylated unit). The optimal composition of calcium alginate chitosan beads is 4 % (wt/vol) alginate gel having 5% loading of chitosan. The nature and morphology of pure and uranium sorbed calcium alginate chitosan beads were characterized by scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), and attenuated total reflectance Fourier transform infrared spectroscopy (ATRFTIR). The results of batch sorption experiments suggest that Cal-Alg-Chi beads are very effective for removal of uranium in the pH range of 2.0-5.0 and sorption is more than 80 % in the concentration range of 1-100 mgL -1

  6. ADSORPTION AND RELEASING PROPERTIES OF BEAD CELLULOSE

    Institute of Scientific and Technical Information of China (English)

    A. Morales; E. Bordallo; V. Leon; J. Rieumont

    2004-01-01

    The adsorption of some dyes on samples of bead cellulose obtained in the Unit of Research-Production "Cuba 9"was studied. Methylene blue, alizarin red and congo red fitted the adsorption isotherm of Langmuir. Adsorption kinetics at pH = 6 was linear with the square root of time indicating the diffusion is the controlling step. At pH = 12 a non-Fickian trend was observed and adsorption was higher for the first two dyes. Experiments carried out to release the methylene blue occluded in the cellulose beads gave a kinetic behavior of zero order. The study of cytochrome C adsorption was included to test a proteinic material. Crosslinking of bead cellulose was performed with epichlorohydrin decreasing its adsorption capacity in acidic or alkaline solution.

  7. Biolimus-eluting biodegradable polymer-coated stent versus durable polymer-coated sirolimus-eluting stent in unselected patients receiving percutaneous coronary intervention (SORT OUT V)

    DEFF Research Database (Denmark)

    Christiansen, Evald Høj; Jensen, Lisette Okkels; Thayssen, Per

    2013-01-01

    Third-generation biodegradable polymer drug-eluting stents might reduce the risk of stent thrombosis compared with first-generation permanent polymer drug-eluting stents. We aimed to further investigate the effects of a biodegradable polymer biolimus-eluting stent compared with a durable polymer......-coated sirolimus-eluting stent in a population-based setting....

  8. Bead Capture on Magnetic Sensors in a Microfluidic System

    DEFF Research Database (Denmark)

    Østerberg, Frederik Westergaard; Dalslet, Bjarke Thomas; Damsgaard, Christian Danvad

    2009-01-01

    The accumulation of magnetic beads by gravitational sedimentation and magnetic capture on a planar Hall-effect sensor integrated in a microfluidic channel is studied systematically as a function of the bead concentration, the fluid flow rate, and the sensor bias current. It is demonstrated...... that the sedimentation flux is proportional to the bead concentration and has a power law relation to the fluid flow rate. The mechanisms for the bead accumulation are investigated and it is found that gravitational sedimentation dominates the bead accumulation, whereas the stability of the sedimented beads against...

  9. Involvement of COX-2 in nickel elution from a wire implanted subcutaneously in mice.

    Science.gov (United States)

    Sato, Taiki; Kishimoto, Yu; Asakawa, Sanki; Mizuno, Natsumi; Hiratsuka, Masahiro; Hirasawa, Noriyasu

    2016-07-01

    Many types of medical alloys include nickel (Ni), and the elution of Ni ions from these materials causes toxicities and inflammation. We have previously reported that inflammation enhances Ni elution, although the molecular mechanisms underlying this effect remain unclear. In this study, we investigated how inflammatory responses enhanced Ni elution in a wire-implantation mouse model. Subcutaneous implantation of Ni wire induced the expression of cyclooxygenase-2 (COX-2) and microsomal prostaglandin E synthase-1 (mPGES-1) mRNA in the surrounding tissues. Immunostaining analysis showed that cells expressing COX-2 were mainly fibroblast-like cells 8h after implantation of a Ni wire, but were mainly infiltrated leukocytes at 24h. NiCl2 induced the expression of COX-2 mRNA in primary fibroblasts, neutrophils, RAW 264 cells, and THP-1 cells, indicating that Ni ions can induce COX-2 expression in various types of cells. The elution of Ni ions from the implanted Ni wire at 8h was reduced by dexamethasone (Dex), indomethacin (Ind), or celecoxib (Cel) treatment. Ni wire implantation induced an increase in mRNA levels for anaerobic glycolytic pathway components glucose transporter 1 (GLUT1), hexokinase 2 (HK2), lactate dehydrogenase A (LDHA), and monocarboxylate transporter 4 (MCT4); the expression of these genes was also inhibited by Dex, Ind, and Cel. In primary fibroblasts, the expression of these mRNAs and the production of lactate were induced by NiCl2 and further potentiated by PGE2. Furthermore, Ni wire-induced infiltration of inflammatory leukocytes was significantly reduced by Dex, Ind, or Cel. Depletion of neutrophils with a specific antibody caused reduction of both leukocyte infiltration and Ni elution. These results indicate that Ni ions eluted from wire induced COX-2 expression, which further promoted elution of Ni ions by increasing lactate production and leukocyte infiltration. Since COX inhibitors and Dex reduced the elution of Ni ions, these drugs may be

  10. Micro-Raman and micro-XRF analysis of glass beads from the Chungde site, Taiwan

    Science.gov (United States)

    Liou, Y. S.; Wang, S. C.; Liu, Y. C.

    2014-12-01

    A large number of ancient glass beads dating back from Late Neolithic Age to early Historical Period (ca. 2300-400 BP) of Taiwan have been uncovered from archaeological sites. These glass beads with variant colors, shapes, and stylistics have long been considered to possess socio-cultural significance. Due to the color and chemical composition of glass bead might be determined by raw materials, fluxing agents, colorants, opacifiers and stabilizers. In addition, ancient glass beads are rare and precious, non-destructive analysis has been employed to decipher about the provenances, manufacturing techniques, and exchange/trade routes. In this work, micro-Raman spectroscopy and micro X-ray fluorescent spectrometer (μ-XRF) were used to examine ten ancient glass beads excavated from the Chungde site, Hualien, Taiwan, dating back to 1500-800 BP, to unravel the mineralogical and chemical compositions. Micro Raman experimental results show that glass and anorthite glass are the main constituents accompanying with trace level of quartz, albite, siderite, ankerite, and amazonite. The Raman Index of Polymerization (Ip) indicate that the sintering temperature of the glass beads is in the range of 1000~1400°C. Furthermore, the chemical compositions are corresponding to the maximum stretching vibration peak wave number (νmax Si-O Stretching) and the maximum bending vibration peak wave number (δmax Si-O Bending), which are essentially consistent with that of the India-Pacific beads. The μ-XRF results indicate the presence of oxides including SiO2, Al2O3, Fe2O3, Na2O, K2O, CaO, MgO, SnO2, TiO2, CuO, etc., and could be classified to high aluminum of soda-lime glass system. According to ternary phase diagram analysis of CaO-K2O-Na2O and K2O-Al2O3-CaO, the ancient glass beads analyzed could be attributed to the India-Pacific beads, and is in accordance with that of Raman spectra. The combination of these facts leads to the conclusion that glass beads obtained from the Chungde

  11. Chitosan and chemically modified chitosan beads for acid dyes sorption

    Institute of Scientific and Technical Information of China (English)

    AZLAN Kamari; WAN SAIME Wan Ngah; LAI KEN Liew

    2009-01-01

    The capabilities of chitosan and chitosan-EGDE (ethylene glycol diglycidyl ether) beads for removing Acid Red 37 (AR 37) and Acid Blue 25 (AB 25) from aqueous solution were examined. Chitosan beads were cross-linked with EGDE to enhance its chemical resistance and mechanical strength. Experiments were performed as a function of pH, agitation period and concentration of AR 37 and AB 25. It was shown that the adsorption capacities of chitosan were comparatively higher than chitosan-EGDE for both acid dyes. This is mainly because cross-linking using EGDE reduces the major adsorption sites -NH3+ on chitosan. Langmuir isotherm model showed best conformity compared to Freundlich and BET. The kinetic experimental data agreed very well to the pseudo second-order kinetic model. The desorption study revealed that after three cycles of adsorption and desorption by NaOH and HCl, both adsorbents retained their promising adsorption abilities. FT-IR analysis proved that the adsorption of acid dyes onto chitosan-based adsorbents was a physical adsorption. Results also showed that chitosan and chitosan-EGDE beads were favourable adsorbers and could be employed as low-cost alternatives for the removal of acid dyes in wastewater treatment.

  12. Irinotecan-Eluting Beads in Treating Patients With Refractory Metastatic Colon or Rectal Cancer That Has Spread to the Liver

    Science.gov (United States)

    2018-02-22

    Liver Metastases; Mucinous Adenocarcinoma of the Colon; Mucinous Adenocarcinoma of the Rectum; Recurrent Colon Cancer; Recurrent Rectal Cancer; Signet Ring Adenocarcinoma of the Colon; Signet Ring Adenocarcinoma of the Rectum; Stage IVA Colon Cancer; Stage IVA Rectal Cancer; Stage IVB Colon Cancer; Stage IVB Rectal Cancer

  13. Use of micrometric latex beads to improve the porosity of hydroxyapatite obtained by chemical coprecipitation method

    Science.gov (United States)

    Webler, G. D.; Rodrigues, W. C.; Silva, A. E. S.; Silva, A. O. S.; Fonseca, E. J. S.; Degenhardt, M. F. S.; Oliveira, C. L. P.; Otubo, L.; Barros Filho, D. A.

    2018-04-01

    Hydroxyapatite is one of the most important biomaterials whose application mainly extends to implants and drug delivery. This work will discuss the changes in the pore size distribution of hydroxyapatite when there are latex beads present during the synthesis. These changes were monitored using different techniques: small angle X-ray scattering, X-ray diffraction, thermal gravimetrical analysis, N2 adsorption, scanning and transmission electron microscopy. Latex beads and hydroxyapatite form a single nanocomposite with well-distinguished inorganic and organic phases. Latex bead removal in the temperature range of 300-600 °C did not modify the original crystalline structure of hydroxyapatite. However, the latex beads favored an increase in the adsorption capacity of mesopores at temperatures higher than their glassy transition (Tg). The main result of this research work consists on the increase of surface area and pore size distribution obtained after the removal of latex beads template. Latex beads have been used in a different approach changing the porosity of hydroxyapatite scaffolds not only introducing new routes for cell integration but also broadening the pore size distribution which can result in a more high efficiency for drug release in living cells.

  14. “Nanofiltration” Enabled by Super-Absorbent Polymer Beads for Concentrating Microorganisms in Water Samples

    Science.gov (United States)

    Xie, Xing; Bahnemann, Janina; Wang, Siwen; Yang, Yang; Hoffmann, Michael R.

    2016-01-01

    Detection and quantification of pathogens in water is critical for the protection of human health and for drinking water safety and security. When the pathogen concentrations are low, large sample volumes (several liters) are needed to achieve reliable quantitative results. However, most microbial identification methods utilize relatively small sample volumes. As a consequence, a concentration step is often required to detect pathogens in natural waters. Herein, we introduce a novel water sample concentration method based on superabsorbent polymer (SAP) beads. When SAP beads swell with water, small molecules can be sorbed within the beads, but larger particles are excluded and, thus, concentrated in the residual non-sorbed water. To illustrate this approach, millimeter-sized poly(acrylamide-co-itaconic acid) (P(AM-co-IA)) beads are synthesized and successfully applied to concentrate water samples containing two model microorganisms: Escherichia coli and bacteriophage MS2. Experimental results indicate that the size of the water channel within water swollen P(AM-co-IA) hydrogel beads is on the order of several nanometers. The millimeter size coupled with a negative surface charge of the beads are shown to be critical in order to achieve high levels of concentration. This new concentration procedure is very fast, effective, scalable, and low-cost with no need for complex instrumentation. PMID:26876979

  15. Drug-eluting stents: from bench-top to clinical research

    NARCIS (Netherlands)

    Basalus, Mounir Welson Zakhary

    2013-01-01

    The development of drug-eluting stents (DES) has improved the invasive treatment of obstructive coronary artery disease by reducing both, restenosis rate and need for reinterventions. This success resulted in a widespread utilization of DES in clinical practice and entailed many clinical research

  16. Behavior of phenolic substances in the decaying process of plants. V. Elution of heavy metals with phenolic acids from soil

    Energy Technology Data Exchange (ETDEWEB)

    Shindo, H; Kuwatsuka, S

    1977-01-01

    The relationship between the elution of heavy metals with phenolic substances and the chemical structure of phenolic substances, as well as the interaction between phenolic substances and metals were studied using batch and column methods. The elution of 3 metals (Fe, Al and Mn) with 4 phenolic acids (rho-hydroxybenzoic, salicylic, ..cap alpha..-resorcylic, and protocatechuic acids) and phthalic acid were investigated using 3 different soils. The results are as follows: (1) The elution of heavy metals was largely influenced by the chemical structures of the phenolic acids. Protocatechuic, salicylic, and phthalic acids which had different chelating sites easily extracted iron, aluminum, and manganese from the soils. Hydroxybenzoic and ..cap alpha..-resorcylic acids which had no chelating sites contributed little to the elution process. (2) In many cases protocatechuic acid showed a stronger affinity to iron than to aluminum, but salicylic acid showed the opposite trend. The affinity of phthalic acid to metals was much less than that of both phenolic acids. (3) The elution of heavy metals was also influenced by the soil pH. The amounts of heavy metals eluted with protocatechuic acid increased as the soil pH increased. The amounts eluted with salicylic and phthalic acids increased as the soil pH decreased. (4) The results suggested that chelating phenolics such as protocatechuic and salicylic acids, which were exuded from plant residues or produced during the decaying process of plant residues, eluted heavy metals such as iron, aluminum and manganese from soil particles and accelerated the downward movement of these metal ions.

  17. Evaluation of differences between dual salt-pH gradient elution and mono gradient elution using a thermodynamic model: Simultaneous separation of six monoclonal antibody charge and size variants on preparative-scale ion exchange chromatographic resin.

    Science.gov (United States)

    Lee, Yi Feng; Jöhnck, Matthias; Frech, Christian

    2018-02-21

    The efficiencies of mono gradient elution and dual salt-pH gradient elution for separation of six mAb charge and size variants on a preparative-scale ion exchange chromatographic resin are compared in this study. Results showed that opposite dual salt-pH gradient elution with increasing pH gradient and simultaneously decreasing salt gradient is best suited for the separation of these mAb charge and size variants on Eshmuno ® CPX. Besides giving high binding capacity, this type of opposite dual salt-pH gradient also provides better resolved mAb variant peaks and lower conductivity in the elution pools compared to single pH or salt gradients. To have a mechanistic understanding of the differences in mAb variants retention behaviors of mono pH gradient, parallel dual salt-pH gradient, and opposite dual salt-pH gradient, a linear gradient elution model was used. After determining the model parameters using the linear gradient elution model, 2D plots were used to show the pH and salt dependencies of the reciprocals of distribution coefficient, equilibrium constant, and effective ionic capacity of the mAb variants in these gradient elution systems. Comparison of the 2D plots indicated that the advantage of opposite dual salt-pH gradient system with increasing pH gradient and simultaneously decreasing salt gradient is the noncontinuous increased acceleration of protein migration. Furthermore, the fitted model parameters can be used for the prediction and optimization of mAb variants separation in dual salt-pH gradient and step elution. © 2018 American Institute of Chemical Engineers Biotechnol. Prog., 2018. © 2018 American Institute of Chemical Engineers.

  18. Beads from Inhumation Rite Burials of Gnezdovo Burial Mound

    Directory of Open Access Journals (Sweden)

    Dobrova Olga P.

    2017-12-01

    Full Text Available The beads from 33 inhumation burials at Gnezdovo burial mound are examined in the article. The beads (total 367 were crafted from stretched tube (258, stretched stick (3, winding (45, press molding (2 pcs., welding (2 pcs., and mosaic beads (9 pcs.. The burial mound contains virtually no broken beads, including the settlement's most common yellow glass beads. Besides glass beads, cornelian, crystal, amber and faience beads have been registered among the burial mound material, as well as beads crafted with metal. Apart from beads, grave inventories contained a series of pendants with a bead strung on a wire ring. The considered complexes contain five pendants of this type. Besides Gnezdovo, similar pendants have been discovered in Kiev, Timerev, Pskov and Vladimir barrows. A comparison between bead sets from Gnezdovo and Kiev burial mounds allows to conclude that the general composition and occurrence frequency of beads is identical for these burials. At the same time, beads crafted with rock crystal, cornelian and metal are more frequently discovered in Kiev inhumations.

  19. Design and characteristics of gellan gum beads for modified release of meloxicam.

    Science.gov (United States)

    Osmałek, Tomasz; Milanowski, Bartłomiej; Froelich, Anna; Szybowicz, Mirosław; Białowąs, Wojciech; Kapela, Marcin; Gadziński, Piotr; Ancukiewicz, Katarzyna

    2017-08-01

    The aim of the presented work was to design, formulate and evaluate the properties of low-acyl gellan macro beads with the potential application as carriers for oral delivery of meloxicam (MLX) in the prophylaxis of colorectal cancer. The beads were obtained by means of ionotropic gelation technique. Calcium chloride (1.0%, 9.0 × 10 -2  M) was used as the cross-linking agent. Nine different polymer, drug and surfactant (Tween ® 80) mixtures were used for production of the beads. The quantitative compositions of the mixtures were generated with the application of the Design of Experiments (DoE) modulus from the STATISTICA Software. The prepared formulations revealed 7.2-27.0% of drug loading and 29.2-50.7% drug encapsulation efficiency. It turned out that 0.5% amount of gellan gum in the mixtures was not sufficient to obtain spherical beads. The morphology and surface of the dried beads were analyzed by SEM. Raman spectra confirmed that MLX did not undergo structural changes during production of the beads. The swelling behavior and degradation of the beads were evaluated in three simulated gastrointestinal fluids at different pH (1.2; 4.5; 6.8). The MLX in vitro release studies were conducted on USP apparatus IV, working in the open loop mode. The obtained results showed that MLX release from the dried beads was pH-dependent. The formulations obtained from mixtures containing 1.0 and 1.5% of gellan may be considered as oral dosage forms for MLX, intended to omit the stomach and release the drug in the distal parts of the gastrointestinal tract.

  20. Arsenate removal by layered double hydroxides embedded into spherical polymer beads: Batch and column studies.

    Science.gov (United States)

    Nhat Ha, Ho Nguyen; Kim Phuong, Nguyen Thi; Boi An, Tran; Mai Tho, Nguyen Thi; Ngoc Thang, Tran; Quang Minh, Bui; Van Du, Cao

    2016-01-01

    In this study, the performance of poly(layered double hydroxides) [poly(LDHs)] beads as an adsorbent for arsenate removal from aqueous solution was investigated. The poly(LDHs) beads were prepared by immobilizing LDHs into spherical alginate/polyvinyl alcohol (PVA)-glutaraldehyde beads (spherical polymer beads). Batch adsorption studies were conducted to assess the effect of contact time, solution pH, initial arsenate concentrations and co-existing anions on arsenate removal performance. The potential reuse of these poly(LDHs) beads was also investigated. Approximately 79.1 to 91.2% of arsenic was removed from an arsenate solution (50 mg As L(-1)) by poly(LDHs). The adsorption data were well described by the pseudo-second-order kinetics model and the Langmuir isotherm model, and the adsorption capacities of these poly(LDHs) beads at pH 8 were from 1.64 to 1.73 mg As g(-1), as calculated from the Langmuir adsorption isotherm. The adsorption ability of the poly(LDHs) beads decreased by approximately 5-6% after 5 adsorption-desorption cycles. Phosphates markedly decreased arsenate removal. The effect of co-existing anions on the adsorption capacity declined in the following order: HPO4 (2-) > HCO3 (-) > SO4 (2-) > Cl(-). A fixed-bed column study was conducted with real-life arsenic-containing water. The breakthrough time was found to be from 7 to 10 h. Under optimized conditions, the poly(LDHs) removed more than 82% of total arsenic. The results obtained in this study will be useful for further extending the adsorbents to the field scale or for designing pilot plants in future studies. From the viewpoint of environmental friendliness, the poly(LDHs) beads are a potential cost-effective adsorbent for arsenate removal in water treatment.

  1. Parental experiences with a hospital-based bead programme for children with congenital heart disease.

    Science.gov (United States)

    Wilson, Valerie; Chando, Shingisai

    2015-02-01

    To present survey findings on parental experiences with a hospital-based bead programme for children with congenital heart disease. The Heart Beads programme commenced at a paediatric hospital in Australia in 2008. Children enrolled in the programme are awarded a distinctive bead for every procedure/treatment they have while in hospital. A previous evaluation study on the programme revealed that the beads are therapeutic for the child and parents; however, due to a small sample size, the results were representative of the experiences of a small number of families who participated in the programme. This was an evaluation study which employed a nonexperimental descriptive design. Surveys were mailed to all eligible families who enrolled in the programme. Data collection occurred between July-December 2012. Questions on parental experiences with the Heart Beads programme were divided into three categories: understanding, acknowledgement and quality. Descriptive statistics were obtained and analysed. One hundred and sixty-two mothers and 136 fathers responded to the survey. Heart Beads assisted mothers (83%) and fathers (80%) with understanding their child's condition and helped them with communication (mothers 80%, fathers 58%). The majority of fathers felt that their experience was acknowledged by nursing staff (64%) and medical staff (62%), while mothers indicated a higher response from nurses (76%) compared to medical staff (67%). Overall, parents rated the programme positively; however, there was some concern that children at times missed out on beads. Understanding how mothers and fathers experience the programme differently can guide staff in their communication with parents and inform future initiatives. The Heart Beads help nurses understand how parents are experiencing care and ways in which they can provide support and acknowledgement of the parent's experience. © 2014 John Wiley & Sons Ltd.

  2. Functional Nanoarchitectures For Enhanced Drug Eluting Stents

    Science.gov (United States)

    Saleh, Yomna E.; Gepreel, Mohamed A.; Allam, Nageh K.

    2017-01-01

    Different strategies have been investigated to allow for optimum duration and conditions for endothelium healing through the enhancement of coronary stents. In this study, a nanoarchitectured system is proposed as a surface modification for drug eluting stents. Highly oriented nanotubes were vertically grown on the surface of a new Ni-free biocompatible Ti-based alloy, as a potential material for self-expandable stents. The fabricated nanotubes were self-grown from the potential stent substrate, which are also proposed to enhance endothelial proliferation while acting as drug reservoir to hinder Vascular Smooth Muscle Cells (VSMC) proliferation. Two morphologies were synthesized to investigate the effect of structure homogeneity on the intended application. The material was characterized by field-emission scanning electron microscope (FESEM), X-ray diffraction (XRD), Raman spectroscopy, energy dispersive X-ray spectroscopy (EDX), and X-ray photoelectron spectroscopy (XPS). Nanoindentation technique was used to study the mechanical properties of the fabricated material. Cytotoxicity and proliferation studies were performed and compared for the two fabricated nanoarchitectures, versus smooth untextured samples, using in-vitro cultured endothelial cells. Finally, the drug loading capacity was experimentally studied and further supported by computational modeling of the release profile.

  3. Rapid Detection of Enterobacter Sakazakii in milk Powder using amino modified chitosan immunomagnetic beads.

    Science.gov (United States)

    Zhu, Yinglian; Wang, Dongfeng

    2016-12-01

    Chitosan immunomagnetic beads (CIBs) were first prepared through converting hydroxyl groups of natural polymer material-chitosan into amino groups using epichlorohydrin and ethylenediamine as modification agent and then coupling with polyclonal antibodies of Enterobacter sakazakii using glutaraldehyde as cross-linking agent. The beads before coupling with antibodies were characterized by magnetic property measurement, FTIR, SEM and XRD technologies. In the assay a natural polysaccharide-chitosan, which has good biological and chemical properties such as non-toxicity, biocompatibility and high chemical reactivity was first used for synthesis of immunomagnetic beads. The detection method first established in this paper that combined the beads with chromogenic medium together to rapid detect E. sakazakii in milk powder could greatly improve the detection specificity and working efficiency. The beads exhibited a maximum capturing capacity of 1×10 6 cfu/g with the detection sensitivity of 4cfu/g. The results demonstrate that the assay is a straightforward, specific and sensitive alternative for rapid detection of E.sakazakii in food matrix. The total analysis time was as little as about 25h, which greatly shorten the detection time. The method can provides new ideas not only to preparation technique of immunomagnetic beads but to imunne detection technique in food safety. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Boiling phenomenon and heat transfer in bead-packed porous structure

    International Nuclear Information System (INIS)

    Zhang Xiaojie; ZHu Yanlei; Bai Bofeng; Yan Xiao; Xiao Zejun

    2009-01-01

    A visual study on pool boiling behavior and phase distribution was conducted on the porous structures made of staggered glass beads at atmospheric pressure. The bead-packed structure was heated on the bottom. The investigations were carried out respectively at different glass bead diameters which were 4 mm, 6 mm and 8 mm. The results show that during subcooled boiling, small isolated bubbles are formed on the heated surface and combine into main-bubbles, the dispersion frequency of the main-bubbles is low and the small bubbles scatter in the bead-packed porous structures. At the initial stage of saturated boiling, the bubble growth rate, the volume of main-bubbles and the range of continuous vapor phase increase. The dispersion frequency of main-bubbles increases with the increasing of heat flux. During film boiling, the heated surface is absolutely covered with vapor film and the porous structure is full of liquid. The larger the diameter of beads is, the higher heat flux is needed for the same phenomenon, and the higher maximum value of heat transfer coefficient will be. During the whole saturated boiling, and the heat transfer enhanced firstly and then weakened. Being opposite to that of the diameters of 4 mm and 8 mm, the heat transfer coefficient in the 6 mm-bead-packed porous structure decreases with the increasing of the heat flux. (authors)

  5. Monoolein-alginate beads as a platform to promote adenosine cutaneous localization and wound healing.

    Science.gov (United States)

    Ng, Wing Y; Migotto, Amanda; Ferreira, Thamyres Soares; Lopes, Luciana B

    2017-09-01

    Alginate beads containing the polar lipid monoolein were developed as a strategy to manage wet wounds by providing improved uptake of excess exudate while releasing adenosine locally for promotion of healing. To obtain monoolein-containing beads, the lipid was mixed with almond oil (2:1w/w), and emulsified within the alginate aqueous dispersion, followed by ionotropic gelation in CaCl 2 solution. Compared to alginate-only, monoolein-alginate systems were 1.44-fold larger, their swelling ability was 1.40-fold higher and adenosine cumulative release was approximately 1.30-fold lower (at 24h). Monoolein-alginate beads were considered safe for topical application as demonstrated by the absence of changes on the viability of reconstructed skin equivalents compared to PBS. Smaller amounts of adenosine were delivered by the beads into and across damaged porcine skin (created by an incisional wound) compared to the drug aqueous solution, and cutaneous localization was favored. More specifically, the beads increased the viable skin layer/receptor phase delivery ratio by approximately 4-fold at 12h post-application. Considering the wide range of adenosine physiological effects and the importance of skin localization for its use in wound healing, these results demonstrate the potential of monoolein-containing beads for localized drug delivery and management of wet wounds. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Chemical surface modification of glass beads for the treatment of paper machine process waters

    International Nuclear Information System (INIS)

    Jradi, Khalil; Daneault, Claude; Chabot, Bruno

    2011-01-01

    Adsorption of detrimental contaminants on a solid sorbent is proposed to remove these contaminants from process waters to increase water recycling and reduce effluent loads in the papermaking industry. A self-assembly process of attaching (covalent grafting) cationic aminosilane molecules to glass beads was investigated. The existence and the hydrolytic stability of self-assembled monolayers and multilayers were confirmed by X-Ray Photoelectron Spectroscopy and contact angle measurements. Effects of reaction time and curing on aminosilane layer structures are also discussed. The curing step after silanization seems to be crucial in the hydrophobization of the quaternary ammonium silane coated onto glass beads, and curing could affect the final chemical structure of the ammonium groups of grafted organosilane. Results indicated that modified glass beads have a strong hydrophobicity, which is attributed to the hydrophobic property of the longest carbon chain grafted onto the glass surface. Adsorption of a model contaminant (stearic acid) onto chemically modified glass beads was determined using colloidal titration. Hydrophobic interactions could be the main driving force involved between the long carbon chains of stearic acid and the carbon chains of the aminosilane layers on glass bead surfaces. Finally, self-assembly processes applied onto glass beads may have two promising applications for papermaking and self-cleaning systems.

  7. Preservation of viability and antibacterial activity of Lactobacillus spp. in calcium alginate beads.

    Science.gov (United States)

    Brachkova, Mariya I; Duarte, Maria A; Pinto, João F

    2010-12-23

    The objective of the study was to produce calcium alginate beads able to deliver Lactobacillus spp. (Lactobacillus plantarum, Lactobacillus rhamnosus GG, Lactobacillus bulgaricus and Lactobacillus lactis) with preserved viability and antibacterial activity. Four types of beads, containing entrapped (E), surface and entrapped (ES), surface (S) and concentrated surface and entrapped lactobacilli (C(ES)) were prepared and physically characterized. The antibacterial activity of lactobacilli cultures before and after immobilization, freeze-drying and throughout storage was studied in relationship to the viable number of lactobacilli. Multi-resistant clinical isolates (methicillin-resistant Staphylococcus aureus, vancomycine-resistant Enterococcus faecalis, VIM-2-metalo-β-lactamase producing Pseudomonas aeruginosa and CTX-M-15-β-lactamase producing strains: Escherichia coli and Klebsiella pneumoniae) were used as indicator strains. Alginate beads in which lactobacilli proliferated to the beads surface (ES and C(ES)) differed significantly from the other types of beads in their physicochemical properties, showing smoother surface morphology, more spherical shape, bigger weight, lower calcium content, density and crushing force. Lactobacilli cultures, at high cell concentrations (10(8)cfu/ml) were active against both Gram-positive and negative multi-resistant bacteria. Beads containing both entrapped and surface lactobacilli (ES) resulted in viability and antibacterial activity most similar to non-processed lactobacilli cultures. The viability and antibacterial activity of the immobilized lactobacilli remained stable after 6 months storage. Copyright © 2010 Elsevier B.V. All rights reserved.

  8. Air plasma processing of poly(methyl methacrylate) micro-beads: Surface characterisations

    International Nuclear Information System (INIS)

    Liu Chaozong; Cui Naiyi; Osbeck, Susan; Liang He

    2012-01-01

    Highlights: ► PMMA micro-beads were processed using a rotary air plasma reactor. ► Surface chemistry and surface texture of PMMA micro-beads were characterised. ► Surface wettability was evaluated using “floating” water contact angle method. ► Surface oxidation and texture changes induced by air plasma attributed to the improvement of surface wettability. - Abstract: This paper reports the surface processing of poly(methyl methacrylate) (PMMA) micro-beads by using a rotary air plasma reactor, and its effects on surface properties. The surface properties, including surface wettability, surface chemistry and textures of the PMMA beads, were characterised. It was observed that the air plasma processing can improve the surface wettability of the PMMA microbeads significantly. A 15 min plasma processing can reduce the surface water contact angle of PMMA beads to about 50° from its original value of 80.3°. This was accompanied by about 8% increase in surface oxygen concentration as confirmed by XPS analysis. The optical profilometry examination revealed the air plasma processing resulted in a rougher surface that has a “delicate” surface texture. It is concluded that the surface chemistry and texture, induced by air plasma processing, co-contributed to the surface wettability improvement of PMMA micro-beads.

  9. Bio-absorbable antibiotic impregnated beads for the treatment of prosthetic vascular graft infections

    Science.gov (United States)

    Genovese, Elizabeth A; Avgerinos, Efthymios D; Baril, Donald T; Makaroun, Michel S; Chaer, Rabih A

    2017-01-01

    Objective There is limited investigation into the use of bio-absorbable antibiotic beads for the treatment of prosthetic vascular graft infections. Our goal was to investigate the rates of infection eradication, graft preservation, and limb salvage in patients who are not candidates for graft explant or extensive reconstruction. Methods A retrospective review of patients implanted with antibiotic impregnated bio-absorbable calcium sulfate beads at a major university center was conducted. Results Six patients with prosthetic graft infections were treated with bio-absorbable antibiotics beads from 2012–2014. Grafts included an aortobifemoral, an aorto-hepatic/superior mesenteric artery, and four extra-anatomic bypasses. Pathogens included Gram-positive and Gram-negative bacteria. Half of the patients underwent graft explant with reconstruction and half debridement of the original graft, all with antibiotic bead placement around the graft. Mean follow-up was 7.3±8.3 months; all patients had infection resolution, healed wounds, and 100% graft patency, limb salvage, and survival. Conclusion This report details the successful use of bio-absorbable antibiotic beads for the treatment prosthetic vascular graft infections in patients at high risk for graft explant or major vascular reconstruction. At early follow-up, we demonstrate successful infection suppression, graft preservation, and limb salvage with the use of these beads in a subset of vascular patients. PMID:26896286

  10. Antibody-integrated and functionalized graphite-encapsulated magnetic beads, produced using ammonia gas plasma technology, for capturing Salmonella.

    Science.gov (United States)

    Sakudo, Akikazu; Chou, Han; Nagatsu, Masaaki

    2015-03-01

    Salmonella spp. is the single and most important causative agent of foodborne infections, especially involving foods such as eggs, milk and meat. To prevent infection, a reliable surveillance system is required that can quickly and sensitively detect Salmonella. Here, we describe the development of antibody-integrated magnetic beads that are functionalized by a novel strategy using ammonia gas plasma. Ammonia plasma, produced by a radio frequency (RF) power supply, was allowed to react with the surface of graphite-encapsulated magnetic beads, resulting in the introduction of amino groups. An anti-Salmonella antibody was then anchored by sulfide groups present on the protein surface to the amino groups of the magnetic beads via N-succinimidyl 3-(2-pyridyldithio) propionate (SPDP). The potential usefulness of these magnetic beads for capturing Salmonella was examined as follows. The beads were incubated with Salmonella in liquid medium and then separated from the supernatant by applying a magnetic field. After thorough washing, adsorption of Salmonella to the beads was confirmed by immunochromatography, polymerase chain reaction and a direct culture assay. Our findings indicate that the capture and concentration of Salmonella using the antibody-integrated magnetic beads was more efficient than commercial Dynabeads® anti-Salmonella, which are conventionally used for concentrating Salmonella from liquid cultures. We believe this novel bead technology will contribute to the enhanced detection of Salmonella. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. A dedicated on-line system for the preparation and validation of standard beads in XRF analysis

    International Nuclear Information System (INIS)

    Yamamoto, Yasuyuki; Ogasawara, Noriko; Nakata, Akio; Shoji, Shizuko.

    1995-01-01

    A dedicated on-line system in X-ray Fluorescence (XRF) analysis with glass-bead method was developed in which preparation of standard beads was automated including proper choice of reagents, assignment of bead compositions and validation of the prepared beads. This system features: a. Fundamental Parameter (FP) Method for validation of standard beads. b. An original database of high purity reagents for standards. c. Automatic calculation of suitable composition for each standard bead, by giving a range for each element and the number of standard beads. 1) The calculation is based on random numbers, and makes a random assignment of composition for each bead. 2) The calculation results are automatically stored in a computer as a condition file for quantitative analysis. 3) An amount of a material for a standard mixture is corrected if a valence or a chemical compound for an analysis element is different from that of the standard material in the database. In order to realize these features, many high purity reagents were examined for their purities and other characteristics to test a suitability to use for a standard material, and a software for on-line processings was originally developed. (author)

  12. exploring traditional glass bead making techniques in jewellery

    African Journals Online (AJOL)

    User

    Glass bead making techniques and their mass production will help the individual ... communicate cultural values in a symbolic lan- guage which ..... Surface of most of the new beads were rough ... tourism potential to be developed further to.

  13. Fungal cultivation on glass-beads

    DEFF Research Database (Denmark)

    Droce, Aida; Sørensen, Jens Laurids; Giese, Henriette

    Transcription of various bioactive compounds and enzymes are dependent on fungal cultivation method. In this study we cultivate Fusarium graminearum and Fusarium solani on glass-beads with liquid media in petri dishes as an easy and inexpensive cultivation method, that resembles in secondary...... metabolite production to agar-cultivation but with an easier and more pure RNA-extraction of total fungal mycelia....

  14. Study on the etched carnelian beads unearthed in China

    Institute of Scientific and Technical Information of China (English)

    Deyun Zhao

    2014-01-01

    Etched carnelian beads originated in the Indus Civilization;this kind of ornaments and its manufacturing techniques were spread to the whole Eurasia Continent.The etched carnelian beads unearthed in China can be classified into four types,the comparisons of which to their foreign counterparts may reveal their different sources and diffusion routes.The etched carnelian beads and their glass imitations unearthed in China had influences to the making of the glass "eye beads" in

  15. Metal-Containing Polystyrene Beads as Standards for Mass Cytometry.

    Science.gov (United States)

    Abdelrahman, Ahmed I; Ornatsky, Olga; Bandura, Dmitry; Baranov, Vladimir; Kinach, Robert; Dai, Sheng; Thickett, Stuart C; Tanner, Scott; Winnik, Mitchell A

    2010-01-01

    We examine the suitability of metal-containing polystyrene beads for the calibration of a mass cytometer instrument, a single particle analyser based on an inductively coupled plasma ion source and a time of flight mass spectrometer. These metal-containing beads are also verified for their use as internal standards for this instrument. These beads were synthesized by multiple-stage dispersion polymerization with acrylic acid as a comonomer. Acrylic acid acts as a ligand to anchor the metal ions within the interior of the beads. Mass cytometry enabled the bead-by-bead measurement of the metal-content and determination of the metal-content distribution. Beads synthesized by dispersion polymerization that involved three stages were shown to have narrower bead-to-bead variation in their lanthanide content than beads synthesized by 2-stage dispersion polymerization. The beads exhibited insignificant release of their lanthanide content to aqueous solutions of different pHs over a period of six months. When mixed with KG1a or U937 cell lines, metal-containing polymer beads were shown not to affect the mass cytometry response to the metal content of element-tagged antibodies specifically attached to these cells.

  16. Controlled torque on superparamagnetic beads for functional biosensors

    NARCIS (Netherlands)

    Janssen, X.J.A.; Schellekens, A.J.; van Ommering, K.; IJzendoorn, van L.J.; Prins, M.W.J.

    2009-01-01

    We demonstrate that a rotating magnetic field can be used to apply a controlled torque on superparamagnetic beads which leads to a tunable bead rotation frequency in fluid. Smooth rotation is obtained for field rotation frequencies many orders of magnitude higher than the bead rotation frequency. A

  17. A Controlled Drug-Delivery Experiment Using Alginate Beads

    Science.gov (United States)

    Farrell, Stephanie; Vernengo, Jennifer

    2012-01-01

    This paper describes a simple, cost-effective experiment which introduces students to drug delivery and modeling using alginate beads. Students produce calcium alginate beads loaded with drug and measure the rate of release from the beads for systems having different stir rates, geometries, extents of cross-linking, and drug molecular weight.…

  18. Assessment of the Problems of Manual Automobile Tyre Bead ...

    African Journals Online (AJOL)

    The tyre-rim bead bond must be broken to carry out repairs on a failed automobile tyre. The use of the locally fabricated manual bead breaking equipment as it is being practiced today by commercial tyre repair artisans in Nigeria is characterized by drudgery. This article reports a study of the local manual bead breaking ...

  19. Studies on the production of technetium-99m generators based on gel elution

    International Nuclear Information System (INIS)

    Castro, M.

    1993-12-01

    Technetium-99m generator based on Ti Mo elution has been carried out. The gel matrix was prepared by mixing non-irradiated molybdate with Titanium Chloride solution. Conditions of preparing and drying Ti Mo were evaluated as a function of elution yield. Thus, pH and water content were found highly critical for reproductiveness of the results. Non-elutable form of Tc-99m can be oxidized treating the target after irradiation with K 2 Cr 2 O 7 0.001M solution. During several experiments the columns were soaked with this oxidizing solution for one hour and afterwards the Ti Mo was washed with 150 ml physiological saline. Daily elutions were done with 10 ml of NaCl 0.9%. Cooling water reactor during irradiation quartz ampoules has been studied. To study this effect, one group of samples were irradiated in aluminium caps air-tight screw and another one was irradiated in drilled caps with six holes to permit water reactor recirculation around quartz ampoules. By combination K 2 Cr 2 O 7 target treatment and cooling Ti Mo during irradiation is possible to get yields of Tc-99m near to 76%. The radiochemical purity was > 99% and Al content < 10ppm , Cr < 0.05ppm , Mo <20ppm, Ti was no detected. Biological scans practiced in animals have been considered satisfactory. (author). 8 refs., 7 tabs., 3 figs

  20. Clopidogrel discontinuation within the first year after coronary drug-eluting stent implantation

    DEFF Research Database (Denmark)

    Thim, Troels; Johansen, Martin Berg; Chisholm, Gro Egholm

    2014-01-01

    BACKGROUND: The impact of adherence to the recommended duration of dual antiplatelet therapy after first generation drug-eluting stent implantation is difficult to assess in real-world settings and limited data are available. METHODS: We followed 4,154 patients treated with coronary drug-eluting ......BACKGROUND: The impact of adherence to the recommended duration of dual antiplatelet therapy after first generation drug-eluting stent implantation is difficult to assess in real-world settings and limited data are available. METHODS: We followed 4,154 patients treated with coronary drug......-eluting stents in Western Denmark for 1 year and obtained data on redeemed clopidogrel prescriptions and major adverse cardiovascular events (MACE, i.e., cardiac death, myocardial infarction, or stent thrombosis) from medical databases. RESULTS: Discontinuation of clopidogrel within the first 3 months after...... stent implantation was associated with a significantly increased rate of MACE at 1-year follow-up (hazard ratio (HR) 2.06; 95% confidence interval (CI): 1.08-3.93). Discontinuation 3-6 months (HR 1.29; 95% CI: 0.70-2.41) and 6-12 months (HR 1.29; 95% CI: 0.54-3.07) after stent implantation were...

  1. Production and setting of fractional elution facility for recovery of useful rare metals from seawater

    International Nuclear Information System (INIS)

    Seko, Noriaki; Kasai, Noboru; Tamada, Masao; Hasegawa, Shin; Katakai, Akio

    2005-01-01

    In September 1999, we have soaked 200 kg of fibrous amidoxime absorbents, synthesized by radiation-induced graft polymerization, into seawater to evaluate their performance. Fractional elution facility was set effectively to elute the rare metals on adsorbents in Mutsu-Establishment. This facility consists of two parts of pre-washing and elution. The present report dealt with planning, manufacture and setting of fractional facility. Marine organism and slime on adsorbent cassette (290 x 295 x 160 mm) were washed out and every 72 cassettes were set in elution unit (1210 x 1210 x H1460 mm) with nonwoven materials as a packing to avoid elution loss. In the elution process alkaline and alkaline earth metals were eluted with low concentration hydrochloric acid (0.01M) and rare metals were eluted with high concentration (0.5 M) after the packing of elution unit into fractional elution facility. Adsorbent cassettes were regenerated with alkaline solution after elution procedure. (author)

  2. Characterization of CRUDE OILS and petroleum products: (i) elution ...

    African Journals Online (AJOL)

    Characterization of CRUDE OILS and petroleum products: (i) elution liquid chromatographic separation and gas chromatographic analysis of crude oils and petroleum products. E.O. Odebunmi, E.A. Ogunsakin, P.E.P. Ilukhor ...

  3. Kuldkaru elutöö eest / Endel Link

    Index Scriptorium Estoniae

    Link, Endel

    2001-01-01

    Ameerika näitleja Kirk Douglas (1916), kellele seekordsel Berlinalel antakse elutöö eest Kuldkaru. Austamisõhtul näidatakse teda Stanley Kubricku kaua keelu all olnud filmis "Tee kuulsusele " ("Paths of Glory") : 1957

  4. Nickel elution properties of contemporary interatrial shunt closure devices.

    Science.gov (United States)

    Verma, Divya Ratan; Khan, Muhammad F; Tandar, Anwar; Rajasekaran, Namakkal S; Neuharth, Renée; Patel, Amit N; Muhlestein, Joseph B; Badger, Rodney S

    2015-02-01

    We sought to compare nickel elution properties of contemporary interatrial shunt closure devices in vitro. There are two United States Food and Drug Administration (FDA)-approved devices for percutaneous closure of secundum atrial septal defect: the Amplatzer septal occluder (ASO; St Jude Medical Corporation) and Gore Helex septal occluder (HSO; W.L. Gore & Associates). The new Gore septal occluder (GSO) device is in clinical trials. These are also used off-label for patent foramen ovale closure in highly selected patients. These devices have high nickel content. Nickel allergy is the most common reason for surgical device explantation. Nickel elution properties of contemporary devices remain unknown. We compared nickel elution properties of 4 devices - ASO, GSO, HSO, and sternal wire (SW) - while Dulbecco's phosphate-buffered saline (DPBS) served as control. Three samples of each device were submerged in DPBS. Nickel content was measured at 14 intervals over 90 days. Nickel elution at 24 hours, compared to control (0.005 ± 0.0 mg/L), was significantly higher for ASO (2.98 ± 1.65 mg/L; P=.04) and SW (0.03 ± 0.014 mg/L; P=.03). Nickel levels at 90 days, compared to control (0.005 ± 0.0 mg/L) and adjusting for multiple comparisons, were significantly higher for ASO (19.80 ± 2.30 mg/L; P=.01) and similar for HSO (P=.34), GSO (P=.34), and SW (P=.34). ASO had significantly higher nickel elution compared to HSO, GSO, and SW (P=.01). There is substantial variability in nickel elution; devices with less exposed nickel (HSO and GSO) have minimal elution. The safety of low nickel elution devices in patients with nickel allergy needs to be evaluated in prospective trials.

  5. Safety and efficacy of everolimus-eluting stents compared with first-generation drug-eluting stents in patients undergoing primary percutaneous coronary intervention

    Energy Technology Data Exchange (ETDEWEB)

    Escárcega, Ricardo O.; Baker, Nevin C.; Magalhaes, Marco A.; Lipinski, Michael J.; Minha, Sa’ar; Torguson, Rebecca; Satler, Lowell F.; Pichard, Augusto D.; Suddath, William O.; Waksman, Ron, E-mail: ron.waksman@medstar.net

    2014-09-15

    Objective: To assess the safety and efficacy everolimus-eluting stents (EES) compared with first-generation drug-eluting stents (DES) in patients with acute myocardial infarction (MI) undergoing primary percutaneous coronary intervention (PCI). Background: EES have been associated with improved clinical outcomes compared to paclitaxel-eluting stents (PES) and with similar outcomes compared to sirolimus-eluting stents (SES). Methods: A total of 520 patients who presented with ST-elevation myocardial infarction (STEMI) from 2003 to 2013, who underwent primary PCI with DES, were retrospectively analyzed. Of these, 247 received SES, 136 PES, and 137 EES. Patients were followed up to 2 years for major adverse cardiac events (MACE). Univariate and multivariate models detected correlates to outcome. Results: EES implantation, compared with PES and SES, resulted in comparable rates of MACE (8.8% vs. 16.2%, p = 0.06 and 8.8% vs. 12.6%, respectively, p = 0.26), stent thrombosis, MI, and target lesion revascularization. Patients who received EES had lower rates of all-cause mortality (3.7% vs. 12.6% vs. 9.4%, p = 0.03) at 1-year follow up. However, in the univariate and multivariate analyses, stent type was not independently associated with the primary outcome or with all-cause mortality. Diabetes mellitus and number of stents implanted were independently associated with the primary outcome. Conclusion: While EES seem to be associated with better outcome when compared to PES, the main correlates of STEMI patients are the presence of diabetes and number of stents implanted, and not the type of stent used for intervention.

  6. Covalent attachment of the plant natural product naringenin to small glass and ceramic beads

    Directory of Open Access Journals (Sweden)

    Grotewold Erich

    2005-10-01

    Full Text Available Abstract Background Natural products have numerous medicinal applications and play important roles in the biology of the organisms that accumulate them. Few methods are currently available for identifying proteins that bind to small molecules, therefore the discovery of cellular targets for natural products with pharmacological activity continues to pose a significant challenge in drug validation. Similarly, the identification of enzymes that participate in the biosynthesis or modification of natural products remains a formidable bottleneck for metabolic engineering. Flavonoids are one large group of natural products with a diverse number of functions in plants and in human health. The coupling of flavonoids to small ceramic and glass beads provides a first step in the development of high-throughput, solid-support base approaches to screen complex libraries to identify proteins that bind natural products. Results The utilization of small glass and ceramic beads as solid supports for the coupling of small molecules was explored. Initial characterization of the beads indicated uniform and high capacity loading of amino groups. Once the beads were deemed adequate for the linking of small molecules by the coupling of NHS-fluorescein followed by microscopy, chemical hydrolysis and fluorometry, the flavonoid naringenin was modified with 1,4-dibromobutane, followed by the attachment of aminopropyltriethoxysilane. After NMR structural confirmation, the resulting 7-(4-(3-(triethoxysilylpropylaminobutoxy naringenin was attached to the ceramic beads. Conclusion Our results demonstrate that ceramic and glass beads provide convenient solid supports for the efficient and facile coupling of small molecules. We succeeded in generating naringenin-coupled ceramic and glass beads. We also developed a convenient series of steps that can be applied for the solid-support coupling of other related flavonoids. The availability of solid-support coupled naringenin opens

  7. Transarterial Chemoembolization for Hepatocellular Carcinoma with a New Generation of Beads: Clinical–Radiological Outcomes and Safety Profile

    Energy Technology Data Exchange (ETDEWEB)

    Spreafico, Carlo, E-mail: carlo.spreafico@istitutotumori.mi.it; Cascella, Tommaso, E-mail: tommaso.cascella@istitutotumori.mi.it [Fondazione Istituto Tumori, Department of Radiology (Italy); Facciorusso, Antonio, E-mail: antonio.facciorusso@istitutotumori.mi.it; Sposito, Carlo, E-mail: carlo.sposito@istitutotumori.mi.it [Fondazione Istituto Tumori, Department of Liver Surgery and Transplant (Italy); Rodolfo, Lanocita, E-mail: rodolfo.lanocita@istitutotumori.mi.it; Morosi, Carlo, E-mail: carlo.morosi@istitutotumori.mi.it; Civelli, Enrico M., E-mail: enrico.civelli@istitutotumori.mi.it; Vaiani, Marta, E-mail: marta.vaiani@istitutotumori.mi.it [Fondazione Istituto Tumori, Department of Radiology (Italy); Bhoori, Sherrie, E-mail: sherrie.bhoori@istitutotumori.mi.it [Fondazione Istituto Tumori, Department of Liver Surgery and Transplant (Italy); Pellegrinelli, Alessandro, E-mail: alessandro.pellegrinelli@istitutotumori.mi.it [Fondazione Istituto Tumori, Department of Pathology (Italy); Marchianò, Alfonso, E-mail: alfonso.marchiano@istitutotumori.mi.it [Fondazione Istituto Tumori, Department of Radiology (Italy); Mazzaferro, Vincenzo, E-mail: vincenzo.mazzaferro@istitutotumori.mi.it [Fondazione Istituto Tumori, Department of Liver Surgery and Transplant (Italy)

    2015-02-15

    PurposeTo evaluate the short-term safety and efficacy of the new generation of 70–150 µm drug-eluting beads (M1 DEB) in patients with hepatocellular carcinoma undergoing transarterial chemoembolization (TACE) as a primary therapy or as a bridge to liver transplantation (LT).MethodsForty-five consecutive patients underwent TACE with M1 DEB loaded with doxorubicin (DEBDOX/M1). Clinical data were recorded at 12, 24, and 48 h, 7 and 30 days after treatment. Response was assessed by computed tomographic scan according to the modified response evaluation criteria in solid tumors criteria, and a second DEBDOX/M1 TACE was scheduled within 6 weeks in case of a noncomplete response.ResultsAll patients had well-compensated cirrhosis (97.7 % Child A, 44.4 % hepatitis C virus, median age 61 years). Twenty patients (44.4 %) had Barcelona Clinic for Liver Cancer class B disease; the median number of nodules and their sum of diameters were 2 (range 1–6) and 43 mm (range 10–190), respectively. The mean number of TACE procedures per patient was 1.4. Objective response rate (complete + partial response) was 77.7 % with a median time to best response of 3 months (95 % confidence interval 2–4). In 13 patients, DEBDOX/M1 TACE served as a bridge/downstaging to LT/surgery. Pathology showed that more than 90 % necrosis was achieved in 10 of 28 nodules. DEBDOX/M1 TACE was well tolerated, and the grade 3/4 adverse event rate was low (1 of 65 procedures).ConclusionDEBDOX/M1 TACE is an effective procedure with a favorable safety profile and promising results in terms of objective response rate, tumor downstaging, and necrosis.

  8. [XPS analysis of beads formed by fuse breaking of electric copper wire].

    Science.gov (United States)

    Wu, Ying; Meng, Qing-Shan; Wang, Xin-Ming; Gao, Wei; Di, Man

    2010-05-01

    The in-depth composition of beads formed by fuse breaking of the electric copper wire in different circumstances was studied by XPS with Ar+ ion sputtering. In addition, the measured Auger spectra and the calculated Auger parameters were compared for differentiation of the substances of Cu and Cu2O. Corresponding to the sputtering depth, the molten product on a bead induced directly by fuse breaking of the copper wire without cover may be distinguished as three portions: surface layer with a drastic decrease in carbon content; intermediate layer with a gentle change in oxygen content and gradually diminished carbon peak, and consisting of Cu2O; transition layer without Cu2O and with a rapid decrease in oxygen content. While the molten product on a bead formed by fuse breaking of the copper wire after its insulating cover had been burned out may be distinguished as two portions: surface layer with carbon content decreasing quickly; subsurface layer without Cu2O and with carbon and oxygen content decreasing gradually. Thus, it can be seen that there was an obvious interface between the layered surface product and the substrate for the first type of bead, while as to the second type of bead there was no interface. As a result, the presence of Cu2O and the quantitative results can be used to identify the molten product on a bead induced directly by fuse breaking of the copper wire without cover and the molten product on a bead formed by fuse breaking of the cupper wire after its insulating cover had been burned out, as a complementary technique for the judgments of fire cause.

  9. Elemental analysis of bead samples using a laser-induced plasma at low pressure

    International Nuclear Information System (INIS)

    Lie, Tjung Jie; Kurniawan, Koo Hendrik; Kurniawan, Davy P.; Pardede, Marincan; Suliyanti, Maria Margaretha; Khumaeni, Ali; Natiq, Shouny A.; Abdulmadjid, Syahrun Nur; Lee, Yong Inn; Kagawa, Kiichiro; Idris, Nasrullah; Tjia, May On

    2006-01-01

    An Nd:YAG laser (1064 nm, 8 ns, 30 mJ) was focused on various types of fresh, fossilized white coral and giant shell samples, including samples of imitation shell and marble. Such samples are extremely important as material for preparing prayer beads that are extensively used in the Buddhist faith. The aim of this research was to develop a non-destructive method to distinguish original beads from their imitations by means of spectral measurements of the carbon, hydrogen, sodium and magnesium emission intensities and by measuring the hardness of the sample using the ratio between Ca (II) 396.8 nm and Ca (I) 422.6 nm. Based on these measurements, original fresh coral beads can be distinguished from any imitation made from hard wood. The same technique was also effective in distinguishing beads made of shell from its imitation. A spectral analysis of bead was also performed on a fossilized white coral sample and the result can be used to distinguish to some extent the fossilized white coral beads from any imitation made from marble. It was also found that the plasma plume should be generated at low ambient pressure to significantly improve the hydrogen and carbon emission intensity and also to avoid energy loss inside the crater during laser irradiation at atmospheric pressure. The results of this study confirm that operating the laser-induced plasma spectroscopy at reduced ambient pressure offers distinct advantage for bead analysis over the conventional laser-induced breakdown spectroscopy (LIBS) technique operated at atmospheric pressure

  10. Elemental analysis of bead samples using a laser-induced plasma at low pressure

    Energy Technology Data Exchange (ETDEWEB)

    Lie, Tjung Jie [Research Center of Maju Makmur Mandiri Foundation, 40 Srengseng Raya, Kembangan, Jakarta Barat 11630 (Indonesia); Kurniawan, Koo Hendrik [Research Center of Maju Makmur Mandiri Foundation, 40 Srengseng Raya, Kembangan, Jakarta Barat 11630 (Indonesia)]. E-mail: kurnia18@cbn.net.id; Kurniawan, Davy P. [Research Center of Maju Makmur Mandiri Foundation, 40 Srengseng Raya, Kembangan, Jakarta Barat 11630 (Indonesia); Pardede, Marincan [Research Center of Maju Makmur Mandiri Foundation, 40 Srengseng Raya, Kembangan, Jakarta Barat 11630 (Indonesia); Suliyanti, Maria Margaretha [Graduate Program in Opto Electrotechniques and Laser Applications, Faculty of Engineering, The University of Indonesia, 4 Salemba Raya, Jakarta 10430 (Indonesia); Khumaeni, Ali [Department of Physics, Faculty of Mathematics and Natural Sciences, Diponegoro University, Tembalang Campus, Semarang 50275 (Indonesia); Natiq, Shouny A. [Department of Physics, Faculty of Mathematics and Natural Sciences, Diponegoro University, Tembalang Campus, Semarang 50275 (Indonesia); Abdulmadjid, Syahrun Nur [Department of Physics, Faculty of Mathematics and Natural Sciences, Syiah Kuala University, Darussalam, Banda Aceh 23116 (Indonesia); Lee, Yong Inn [Physics Department, Chonbuk National University, Chonju 561-756, South Korea (Korea); Kagawa, Kiichiro [Department of Physics, Faculty of Education and Regional Studies, Fukui University, 9-1 bunkyo 3-chome, Fukui 910-8507 (Japan); Idris, Nasrullah [Department of Physics, Faculty of Education and Regional Studies, Fukui University, 9-1 bunkyo 3-chome, Fukui 910-8507 (Japan); Tjia, May On [Department of Physics, Faculty of Mathematics and Natural Sciences, Bandung Institute of Technology, 10 Ganesha, Bandung 40132 (Indonesia)

    2006-01-15

    An Nd:YAG laser (1064 nm, 8 ns, 30 mJ) was focused on various types of fresh, fossilized white coral and giant shell samples, including samples of imitation shell and marble. Such samples are extremely important as material for preparing prayer beads that are extensively used in the Buddhist faith. The aim of this research was to develop a non-destructive method to distinguish original beads from their imitations by means of spectral measurements of the carbon, hydrogen, sodium and magnesium emission intensities and by measuring the hardness of the sample using the ratio between Ca (II) 396.8 nm and Ca (I) 422.6 nm. Based on these measurements, original fresh coral beads can be distinguished from any imitation made from hard wood. The same technique was also effective in distinguishing beads made of shell from its imitation. A spectral analysis of bead was also performed on a fossilized white coral sample and the result can be used to distinguish to some extent the fossilized white coral beads from any imitation made from marble. It was also found that the plasma plume should be generated at low ambient pressure to significantly improve the hydrogen and carbon emission intensity and also to avoid energy loss inside the crater during laser irradiation at atmospheric pressure. The results of this study confirm that operating the laser-induced plasma spectroscopy at reduced ambient pressure offers distinct advantage for bead analysis over the conventional laser-induced breakdown spectroscopy (LIBS) technique operated at atmospheric pressure.

  11. An everolimus-eluting stent versus a paclitaxel-eluting stent in small vessel coronary artery disease: a pooled analysis from the SPIRIT II and SPIRIT III trials.

    Science.gov (United States)

    Bartorelli, Antonio L; Serruys, Patrick W; Miquel-Hébert, Karine; Yu, Shui; Pierson, Wes; Stone, Gregg W

    2010-07-01

    To evaluate the safety and efficacy of the XIENCE V everolimus-eluting stent compared to the TAXUS paclitaxel-eluting stent in small vessels. The XIENCE V everolimus-eluting stent (EES) has been shown to improve angiographic and clinical outcomes after percutaneous myocardial revascularization, but its performance in small coronary arteries has not been investigated. In this pooled analysis, we studied a cohort of 541 patients with small coronary vessels (reference diameter SPIRIT II and SPIRIT III studies. TAXUS Express (73% of lesions) and TAXUS Liberté (27% of lesions) paclitaxel-eluting stents (PES) were used as controls in SPIRIT II. In SPIRIT III, Taxus Express(2) PES was the control. Mean angiographic in-stent and in-segment late loss was significantly less in the EES group compared with the PES group, (0.15 +/- 0.37 mm vs. 0.30 +/- 0.44 mm; P = 0.011 for in-stent; 0.10 +/- 0.38 mm vs. 0.21 +/- 0.34 mm; P = 0.034 for in-segment). EES also resulted in a significant reduction in composite major adverse cardiac events at 1 year (19/366 [5.2%] vs. 17/159 [10.7%]; P = 0.037), due to fewer non-Q-wave myocardial infarctions and target lesion revascularizations. At 1 year, the rate of non-Q-wave myocardial infarction was significantly lower in the EES group compared with that of the PES group (6/366 [1.6%] vs. 8/159 [5.0%]; P = 0.037). In patients with small vessel coronary arteries, the XIENCE V EES was superior to the TAXUS PES. (c) 2010 Wiley-Liss, Inc.

  12. The control of beads diameter of bead-on-string electrospun nanofibers and the corresponding release behaviors of embedded drugs

    Energy Technology Data Exchange (ETDEWEB)

    Li, Tingxiao [Key Laboratory of Textile Science and Technology (Donghua University), Ministry of Education of China, Shanghai 201620 (China); College of Textiles, Donghua University, Shanghai 201620 (China); Ding, Xin, E-mail: xding@dhu.edu.cn [Key Laboratory of Textile Science and Technology (Donghua University), Ministry of Education of China, Shanghai 201620 (China); College of Textiles, Donghua University, Shanghai 201620 (China); Tian, Lingling, E-mail: lingling_tian@nus.edu.sg [Center of Nanofibers & Nanotechnology, Department of Mechanical Engineering, National University of Singapore, 117576 (Singapore); Hu, Jiyong; Yang, Xudong [Key Laboratory of Textile Science and Technology (Donghua University), Ministry of Education of China, Shanghai 201620 (China); College of Textiles, Donghua University, Shanghai 201620 (China); Ramakrishna, Seeram [Center of Nanofibers & Nanotechnology, Department of Mechanical Engineering, National University of Singapore, 117576 (Singapore); Guangdong-Hongkong-Macau Institute of CNS Regeneration (GHMICR), Jinan University, Guangzhou 510632 (China)

    2017-05-01

    Bead-on-string nanofibers, with appropriate control of the beads diameter, are potential fibrous structures for efficient encapsulation of particle drugs in micron scales and could achieve controlled drug release for tissue engineering applications. In this study, the beads diameter of electrospun bead-on-string nanofibers was controlled by adjusting the concentration of spinning polymer, poly (lactic-co-glycolic acid) (PLGA), and the solvent ratio of chloroform to acetone. The images of the scanning electron microscopy (SEM) suggested that bead-on-string nanofibers could be successfully obtained only with a certain range of PLGA solution concentration. Moreover, with the decrease in the solvent ratio of chloroform to acetone, the range was left-shifted towards a smaller concentration. In addition, increase in the PLGA solution concentration within the range the beads diameter became greater and the shape of the beads changed from oval to slender when increasing the PLGA concentration within the range. The bead-on-string nanofibers with different beads diameter were further used to load micro-particle drugs of tetracycline hydrochloride, as a model drug, to examine the release behavior of nanofibers scaffold. The release profiles of drug loaded bead-on-string nanofibers demonstrated the possibility to alleviate the burst drug release by means of beads diameter control. - Highlights: • Bead diameter of bead-on-string electrospun nanofibers was controlled by varying solvent ratio and polymer concentration. • The effect of the addition of particle drugs on BD of bead-on-string electrospun nanofibers was studied. • The corresponding release behaviors of nanofibers with different BD loading micro-particle drugs were investigated. • Bead-on-string nanofibers with bigger BD could alleviate the initial burst release.

  13. The control of beads diameter of bead-on-string electrospun nanofibers and the corresponding release behaviors of embedded drugs

    International Nuclear Information System (INIS)

    Li, Tingxiao; Ding, Xin; Tian, Lingling; Hu, Jiyong; Yang, Xudong; Ramakrishna, Seeram

    2017-01-01

    Bead-on-string nanofibers, with appropriate control of the beads diameter, are potential fibrous structures for efficient encapsulation of particle drugs in micron scales and could achieve controlled drug release for tissue engineering applications. In this study, the beads diameter of electrospun bead-on-string nanofibers was controlled by adjusting the concentration of spinning polymer, poly (lactic-co-glycolic acid) (PLGA), and the solvent ratio of chloroform to acetone. The images of the scanning electron microscopy (SEM) suggested that bead-on-string nanofibers could be successfully obtained only with a certain range of PLGA solution concentration. Moreover, with the decrease in the solvent ratio of chloroform to acetone, the range was left-shifted towards a smaller concentration. In addition, increase in the PLGA solution concentration within the range the beads diameter became greater and the shape of the beads changed from oval to slender when increasing the PLGA concentration within the range. The bead-on-string nanofibers with different beads diameter were further used to load micro-particle drugs of tetracycline hydrochloride, as a model drug, to examine the release behavior of nanofibers scaffold. The release profiles of drug loaded bead-on-string nanofibers demonstrated the possibility to alleviate the burst drug release by means of beads diameter control. - Highlights: • Bead diameter of bead-on-string electrospun nanofibers was controlled by varying solvent ratio and polymer concentration. • The effect of the addition of particle drugs on BD of bead-on-string electrospun nanofibers was studied. • The corresponding release behaviors of nanofibers with different BD loading micro-particle drugs were investigated. • Bead-on-string nanofibers with bigger BD could alleviate the initial burst release.

  14. PREPRARATION OF CoPcS/TiO2/BEADS AND THEIR PHOTOCATALYTIC REACTIVITY FOR PHOTODEGRADATION OF VEGETABLE OIL FLOATING ON WATER

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The paper introduces the preparation of floating TiO2/beads photocalyst attached to the hollow glass micro-beads surface by sol-gel technique using tetrabutyl titanate as material and the preparation of floating CoPcS/TiO2/beads by dip-coatig technique. The optimal factor of degradation of vegetable oil floating on water using CoPcS/TiO2/beads was studied. The result showed that the removal rate of vegetable oil floating on water can highly reach 90% at the optimal condition (acidity or neutrality, 375W medium-pressure mercury vapour lamp, illumination 2h~3h, 1g CoPcS/TiO2/beads). The photocatalytic removal efficiency causing by CoPcS/TiO2/beads was increased rapidly by adding a trace amount of H2O2.

  15. PREPRARATION OF CoPcS/TiO2/BEADS AND THEIR PHOTOCATALYTIC REACTIVITY FOR PHOTODEGRADATION OF VEGETABLE OIL FLOATING ON WATER

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xiaoye; YAN Yongsheng; KONG Feng; WANG Yun

    2007-01-01

    The paper introduces the preparation of floating TiO2/beads photocalyst attached to the hollow glass micro-beads surface by sol-gel technique using tetrabutyl titanate as material and the preparation of floating CoPcS/TiO2/beads by dip-coatig technique. The optimal factor of degradation of vegetable oil floating on water using CoPcS/TiO2/beads was studied. The result showed that the removal rate of vegetable oil floating on water can highly reach 90% at the optimal condition (acidity or neutrality, 375W medium-pressure mercury vapour lamp, illumination 2h~3h, 1g CoPcS/TiO2/beads). The photocatalytic removal efficiency causing by CoPcS/TiO2/beads was increased rapidly by adding a trace amount of H2O2.

  16. Aptamer-Modified Magnetic Beads in Biosensing

    Science.gov (United States)

    Scheper, Thomas; Walter, Johanna-Gabriela

    2018-01-01

    Magnetic beads (MBs) are versatile tools for the purification, detection, and quantitative analysis of analytes from complex matrices. The superparamagnetic property of magnetic beads qualifies them for various analytical applications. To provide specificity, MBs can be decorated with ligands like aptamers, antibodies and peptides. In this context, aptamers are emerging as particular promising ligands due to a number of advantages. Most importantly, the chemical synthesis of aptamers enables straightforward and controlled chemical modification with linker molecules and dyes. Moreover, aptamers facilitate novel sensing strategies based on their oligonucleotide nature that cannot be realized with conventional peptide-based ligands. Due to these benefits, the combination of aptamers and MBs was already used in various analytical applications which are summarized in this article. PMID:29601533

  17. RF Bead Pull Measurements of the DQW

    CERN Document Server

    Jaume, Guillaume

    2015-01-01

    This report was written within the framework of the CERN Summer Student Program. It is focused on the Radio Frequency study of the Double Quarter Wave Crab Cavity [1] considered for the crab-crossing scheme of the LHC Luminosity upgrade [2]. HFSS simulation [3] and Bead-Pull Measurements technique were used for the characterization of the higher-order terms of the main deflecting mode.

  18. Development of liposomes entrapped in alginate beads for the treatment of colorectal cancer.

    Science.gov (United States)

    Bansal, Divya; Gulbake, Arvind; Tiwari, Jyoti; Jain, Sanjay K

    2016-01-01

    Folic Acid conjugated liposomes encapsulating Oxaliplatin (L-OHP) were entrapped in alginate beads and further coated with Eudragit-S-100 for effective delivery to colon tumors. Liposomes were prepared by cast film method and folic acid was coupled on the surface of liposomes. They were further entrapped in alginate beads which were Eudragit coated for degradation in the colonic region. The prepared beads were characterized for shape and surface morphology, percentage entrapment efficiency and drug release studies. The in vitro drug release was investigated using a USP dissolution paddle type apparatus in different simulated gastrointestinal fluids. In vivo studies of the beads containing free drug, folic acid coupled and uncoupled liposomes bearing L-OHP was administered orally at the dose of 10mg L-OHP/kg body weight to tumor bearing NUDE/SCID mice. γ-Scintigraphic study showed that Eudragit coated alginate beads entered into the colon of Balb/c mice between 4.20 and 4.50h after oral administration. In vivo data showed that folic acid coupled liposomes entrapped in alginate beads delivered 2.82 ± 0.58 and 21.52 ± 2.76 μg L-OHP/g tissues in the colon and tumor after 12h, reflecting its targeting potential to colon and tumor. The results clearly demonstrate that Eudragit coated calcium alginate beads bearing folic acid coupled liposome can be used as a prospective carrier for drug delivery to colon specific tumor. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Alginate/magnetite hybrid beads for magnetically stimulated release of dopamine.

    Science.gov (United States)

    Kondaveeti, Stalin; Cornejo, Daniel R; Petri, Denise Freitas Siqueira

    2016-02-01

    Hybrid beads composed of magnetite nanoparticles (MNP) and alginate (Alg) were synthesized and coded as Alg-MNP. They were incubated in dopamine (DOPA) solution (5 g/L), at pH 7.4 and 8 °C, during 12 h, promoting the DOPA loaded magnetic beads, coded as Alg-MNP/DOPA. The release of DOPA was further evaluated in the absence and the presence of external magnetic field (EMF) of 0.4 T. The products Alg-MNP and Alg-MNP/DOPA were characterized by scanning electron microscopy with energy dispersive spectroscopy (SEM-EDS), Fourier transform infrared vibrational spectroscopy (FTIR), UV spectrophotometry, thermogravimetric analyses (TGA), inductively coupled plasma atomic emission spectroscopy (ICP-AES) analyses and superconducting quantum interference device (SQUID) magnetometer. The magnetic and chemical properties of Alg-MNP beads were not affected by DOPA loading. The incorporation of DOPA into the beads depended on the pH and on the negative charge density. At pH 7.4 38% of DOPA were loaded into Alg-MNP beads, whereas at pH 2 or using neat Alg beads (lower charge density than Alg-MNP) the loading efficiency decreased to one third or less. In the absence of EMF, 24% of the loaded DOPA was released from Alg-MNP at pH 7.4 over a period of 26 h. The released amount increased to 33% under the stimulus of EMF. A model was proposed to explain the loading efficiency of charged drugs, as DOPA, into hybrid beads and the role played by EMF on delivery systems, where drug and matrix are oppositely charged. The results suggest that the alginate combined with magnetite nanoparticles is a promising system for release of DOPA in the presence of EMF. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Recovery of uranium from phosphoric acid medium by polymeric composite beads encapsulating organophosphorus extractants

    Energy Technology Data Exchange (ETDEWEB)

    Singh, D.K.; Yadav, K.K.; Varshney, L.; Singh, H. [Bhabha Atomic Research Centre, Mumbai 400 085 (India)

    2013-07-01

    The present study deals with the preparation and evaluation of the poly-ethersulfone (PES) based composite beads encapsulating synergistic mixture of D2EHPA and Cyanex 923 (at 4:1 mole ratio) for the separation of uranium from phosphoric acid medium. SEM was used for the characterization of the composite materials. Addition of 1% PVA (polyvinyl alcohol) improved the internal morphology and porosity of the beads. Additionally, microscopic examination of the composite bead confirmed central coconut type cavity surrounded by porous polymer layer of the beads through which exchange of metal ions take place. Effect of various experimental variables including aqueous acidity, metal ion concentration in aqueous feed, concentration of organic extractant inside the beads, extractant to polymer ratio, liquid to solid (L/S) ratio and temperature on the extraction of uranium was studied. Increase in acidity (1-6 M), L/S ratio (1- 10), metal ion concentration (0.2-3 g/L U{sub 3}O{sub 8}) and polymer to extractant ratio (1:4 -1:10) led to decrease in extraction of uranium. At 5.5 M (comparable to wet process phosphoric acid concentration) the extraction of uranium was about 85% at L/S ratio 5. Increase in extractant concentration inside the bead resulted in enhanced extraction of metal ion. Increase in temperature in the range of 30 to 50 Celsius degrees increased the extraction, whereas further increase to 70 C degrees led to the decrease in extraction of uranium. Amongst various reagents tested, stripping of uranium was quantitative by 12% Na{sub 2}CO{sub 3} solution. Polymeric beads were found to be stable and reusable up-to 10 cycles of extraction/stripping. (authors)

  1. Multilayer sodium alginate beads with porous core containing chitosan based nanoparticles for oral delivery of anticancer drug.

    Science.gov (United States)

    Li, Jing; Jiang, Changqing; Lang, Xuqian; Kong, Ming; Cheng, Xiaojie; Liu, Ya; Feng, Chao; Chen, Xiguang

    2016-04-01

    To develop efficient and safe anticancer drug doxorubicin hydrochloride (DOX) delivery system for oral chemotherapy, chitosan based nanoparticles (CS/CMCS-NPs) composed of chitosan (CS) and o-carboxymeymethy chitosan (CMCS) were immobilized in multilayer sodium alginate beads (NPs-M-Beads). Two kinds of NPs-M-Beads, with or without porous core, were respectively prepared by internal or external ionic gelation method. In the small intestine, the intact CS/CMCS-NPs were able to escape from porous-beads and sustained release the loading DOX. In vivo results showed that the DOX could be efficiently absorbed by small intestine of SD rat and the higher concentration of the DOX in major organs of rats were found after oral administration of Porous-Beads, which were about 2-4 folds higher than that of non-porous-beads. These results suggested that the NPs-M-Beads with porous core to be exciting and promising for oral delivery of DOX. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Spray drying of bead resins: feasibility tests

    International Nuclear Information System (INIS)

    Gay, R.L.; Grantham, L.F.; Jones, L.J.

    1984-01-01

    Rockwell International has developed a volume reduction system for low-level reactor wastes based on drying the wastes in a heated-air spray dryer. The drying of slurries of sodium sulfate, boric acid, and powdered ion exchange resins was demonstrated in previous tests. The drying of bead ion exchange resins can be especially difficult due to the relatively large size of bead resins (about 500 to 800 microns) and their natural affinity for water. This water becomes part of the pore structure of the resins and normally comprises 50 t 60 wt % of the resin weight. A 76-cm-diameter spray dryer was used for feasibility tests of spray drying of cation and anion bead resins. These resins were fed to the dryer in the as-received form (similar to dewatered resins) and as slurries. A dry, free-flowing product was produced in all the tests. The volume of the spray-dried product was one-half to one-third the volume of the as-received material. An economic analysis was made of the potential cost savings that can be achieved using the Rockwel spray dryer system. In-plant costs, transportation costs, and burial costs of spray-dried resins were compared to similar costs for disposal of dewatered resins. A typical utility producing 170 m 3 (6,000 ft 3 ) per year of dewatered resins can save $600,000 to $700,000 per year using this volume reduction system

  3. Cultivation of human dermal fibroblasts and epidermal keratinocytes on keratin-coated silica bead substrates.

    Science.gov (United States)

    Tan, Bee Yi; Nguyen, Luong T H; Kim, Hyo-Sop; Kim, Jae-Ho; Ng, Kee Woei

    2017-10-01

    Human hair keratin is promising as a bioactive material platform for various biomedical applications. To explore its versatility further, human hair keratin was coated onto monolayers of silica beads to produce film-like substrates. This combination was hypothesized to provide a synergistic effect in improving the biochemical properties of the resultant composite. Atomic force microscopy analysis showed uniform coatings of keratin on the silica beads with a slight increase in the resulting surface roughness. Keratin-coated silica beads had higher surface energy and relatively lower negative charge than those of bare silica beads. To investigate cell response, human dermal fibroblasts (HDFs), and human epidermal keratinocytes (HEKs) were cultured on the substrates over 4 days. Results showed that keratin coatings significantly enhanced the metabolic activity of HDFs and encouraged cell spreading but did not exert any significant effects on HEKs. HDF expression of collagen I was significantly more intense on the keratin-coated compared to the bare silica substrates. Furthermore, HDF secretion of various cytokines suggested that keratin coatings triggered active cell responses related to wound healing. Collectively, our study demonstrated that human hair keratin-coated silica bead monolayers have the potential to modulate HDF behavior in culture and may be exploited further. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 2789-2798, 2017. © 2017 Wiley Periodicals, Inc.

  4. SparseBeads data: benchmarking sparsity-regularized computed tomography

    Science.gov (United States)

    Jørgensen, Jakob S.; Coban, Sophia B.; Lionheart, William R. B.; McDonald, Samuel A.; Withers, Philip J.

    2017-12-01

    Sparsity regularization (SR) such as total variation (TV) minimization allows accurate image reconstruction in x-ray computed tomography (CT) from fewer projections than analytical methods. Exactly how few projections suffice and how this number may depend on the image remain poorly understood. Compressive sensing connects the critical number of projections to the image sparsity, but does not cover CT, however empirical results suggest a similar connection. The present work establishes for real CT data a connection between gradient sparsity and the sufficient number of projections for accurate TV-regularized reconstruction. A collection of 48 x-ray CT datasets called SparseBeads was designed for benchmarking SR reconstruction algorithms. Beadpacks comprising glass beads of five different sizes as well as mixtures were scanned in a micro-CT scanner to provide structured datasets with variable image sparsity levels, number of projections and noise levels to allow the systematic assessment of parameters affecting performance of SR reconstruction algorithms6. Using the SparseBeads data, TV-regularized reconstruction quality was assessed as a function of numbers of projections and gradient sparsity. The critical number of projections for satisfactory TV-regularized reconstruction increased almost linearly with the gradient sparsity. This establishes a quantitative guideline from which one may predict how few projections to acquire based on expected sample sparsity level as an aid in planning of dose- or time-critical experiments. The results are expected to hold for samples of similar characteristics, i.e. consisting of few, distinct phases with relatively simple structure. Such cases are plentiful in porous media, composite materials, foams, as well as non-destructive testing and metrology. For samples of other characteristics the proposed methodology may be used to investigate similar relations.

  5. Microscope-controlled glass bead blasting: a new technique

    Directory of Open Access Journals (Sweden)

    Peter Kotschy

    2011-01-01

    Full Text Available Peter Kotschy1, Sascha Virnik2, Doris Christ3, Alexander Gaggl21Private Practice, Vienna, Austria; 2Department of Oral and Maxillofacial Surgery, Central Hospital, Klagenfurt, Austria; 3Klagenfurt, AustriaObjective: The aim of periodontal therapy is the healing of periodontal inflammation; the protection of the attachment and the alveolar bone; and the regeneration of the periodontal structures. In the therapy of periodontitis, supra- and subgingival scaling and root planing plays a main role. The procedure described combines perfect root cleaning without scaling and root planing and minimal invasive periodontal surgery without a scalpel.Material and methods: Glass beads of 90 µm were used with the kinetic preparation unit PrepStart® under a pressure of 0.5–5 bar. This technique was practised only under visual control using the OPMI® PRO Magis microscope. Seven examinations were carried out at baseline after 3, 6, 12, 18, 24, and 36 months.Results: Time shows a statistically significant influence on all of the considered target variables (P < 0.0001 for all. As the according estimate is negative, probing depth decreases over time. The major decrease seems to be during the first 6 months. Considering probing depth, plaque on the main effect root shows significant influence (again, P < 0.0001 for all. Observations with high probing depth at the beginning were faster than those with low probing depth. The same characteristic appears by attachment level. Patients with more loss of attachment show more gain.Conclusions: Using microscope-controlled glass bead blasting results in a perfectly clean root surface using visual control (magnification 20×. Microscope-controlled glass bead blasting is therefore a good alternative to periodontal surgery.Keywords: periodontal therapy, microscope, periodontitis

  6. Effects of Magnetic Particles Entrance Arrangements on Mixing Efficiency of a Magnetic Bead Micromixer

    Institute of Scientific and Technical Information of China (English)

    Reza Kamali; Seyed Alireza Shekoohi; Alireza Binesh

    2014-01-01

    In this study, a computer code is developed to numerically investigate a magnetic bead micromixer under different conditions. The micromixer consists of a microchannel and numerous micro magnetic particles which enter the micromixer by fluid flows and are actuated by an alternating magnetic field normal to the main flow. An important feature of micromixer which is not considered before by researchers is the particle entrance arrangement into the micromixer. This parameter could effectively affect the micromixer efficiency. There are two general micro magnetic particle entrance arrangements in magnetic bead micromixers: determined position entrance and random position entrance. In the case of determined position entrances, micro magnetic particles enter the micromixer at specific positions of entrance cross section. However, in a random position entrance,particles enter the microchannel with no order. In this study mixing efficiencies of identical magnetic bead micromixers which only differ in particle entrance arrangement are numerically investigated and compared.The results reported in this paper illustrate that the prepared computer code can be one of the most powerful and beneficial tools for the magnetic bead micromixer performance analysis. In addition, the results show that some features of the magnetic bead micromixer are strongly affected by the entrance arrangement of the particles.

  7. The characterization of ceramic alumina prepared by using additive glass beads

    Science.gov (United States)

    Suprapedi; Muljadi; Sardjono, Priyo

    2018-01-01

    The ceramic alumina has been made by using additive glass bead (5 and 10 % wt.). There are two kinds of materials, such as : gamma Alumina and glass bead. Synthesis of alumina was done by ball milling for 24 hours, then the mixed powder was dried in drying oven at 100 °C for 6 hours. Furthermore, the dried powder was mixed by using 2 % of PVA and continued with compacted to form a pellet with pressure of 50 MPA. The next step is sintering process with variation temperature of 1150, 1200, 1250, 1300 and 1400 °C and holding time for 2 hours. The characterization conducted are consist of test density, hardness, shrinkage, and microstructure. The results show that ceramic alumina with addition of 10 % wt. glass bead has the higher value of density, hardness and shrinkage than addition of 5% wt. glass bead. The highest characterization of ceramic alumina with addition 10 % glass bead was achieved at sintering temperature of 1400 °C with density 3.68 g/cm3, hardness vickers 780.40 Hv and shrinkage 15.23 %. The XRD results show that it was founds a corrundum (alpha Alumina) as dominant phase and mullite as minor phase.

  8. Physical and chemical analysis of glass beads and glassy slag from Iron Age sites in northeast Thailand : preliminary findings

    International Nuclear Information System (INIS)

    Saitowitz, S.J.; Reid, D.L.

    2001-01-01

    Substantial numbers of glass beads have been found at the Iron Age site of Noen U-Loke (ca. 850 BC to AD 500) in northeast Thailand. Typological classification of the beads, using standardised procedures, together with specialized analytical data show that while distinctly different bead-making techniques were used to produce the beads, the chemical composition of the glass was very similar. This information suggests the possibility of multiple craftsmen, at varied levels of expertise, using glass made at a single source or using raw materials found within a specific region. These findings allow for more detailed physical and chemical analysis of the beads, so as to quantify the spatial and temporal variability of different bead types. A fragment of glassy slag, excavated at Noen U-Loke, was analysed to distinguish whether it could be associated with a glass making process. However, the results were unable to confirm whether it was used to make glass suitable for beads. (author). 30 refs., 12 figs., 2 tabs

  9. Impact of Microplastic Beads and Fibers on Waterflea (Ceriodaphnia dubia) Survival, Growth, and Reproduction: Implications of Single and Mixture Exposures.

    Science.gov (United States)

    Ziajahromi, Shima; Kumar, Anupama; Neale, Peta A; Leusch, Frederic D L

    2017-11-21

    There is limited knowledge regarding the adverse effects of wastewater-derived microplastics, particularly fibers, on aquatic biota. In this study, we examined the acute (48 h) and chronic (8 d) effects of microplastic polyester fibers and polyethylene (PE) beads on freshwater zooplankton Ceriodaphnia dubia. We also assessed the acute response of C. dubia to a binary mixture of microplastic beads and fibers for the first time. Acute exposure to fibers and PE beads both showed a dose-dependent effect on survival. An equitoxic binary mixture of beads and fibers resulted in a toxic unit of 1.85 indicating less than additive effects. Chronic exposure to lower concentrations did not significantly affect survival of C. dubia, but a dose-dependent effect on growth and reproduction was observed. Fibers showed greater adverse effects than PE beads. While ingestion of fibers was not observed, scanning electron microscopy showed carapace and antenna deformities after exposure to fibers, with no deformities observed after exposure to PE beads. While much of the current research has focused on microplastic beads, our study shows that microplastic fibers pose a greater risk to C. dubia, with reduced reproductive output observed at concentrations within an order of magnitude of reported environmental levels.

  10. X-ray fluorescent analysis on Indo-Pacific glass beads from Sungai Mas archaeological sites, Kedah, Malaysia

    International Nuclear Information System (INIS)

    Zuliskandar Ramli; Nik Hassan Shuhaimi; Nik Abdul Rahman; Abdul Latif Samian

    2011-01-01

    Sungai Mas was an ancient port-kingdom located on West Coast of Peninsula Malaysia in a district of Kota Kuala Muda, Kedah, Malaysia. The port-kingdom evolved as an entrepot since fifth century AD and continuously visited by international trader from India, China, Middle East and Europe until eighteenth century AD. Sungai Mas was also one of the Indo-Pacific beads making centers in Southeast Asia since sixth to thirteenth century AD and also produced pottery and brick. X-ray fluorescent analysis (XRF) on Sungai Mas Indo-Pacific beads is carried out to determine whether the glass beads originated from Arikamedu, India or locally made by community in Sungai Mas. Totally, twenty-two samples of beads and beads materials assayed by XRF were chosen. Contents of nine major elements and nine trace elements, which might be present of flux, stabilizer, colorants or opacifier were examined. The elements Si, Na, K, Ca, Fe, Al, Ti, Mn, Mg, Cu, Pb, Zr, Sr, Ba, La, U, Ni and Cr were detectable in all samples. The concentration of elements found are discussed in terms of flux, silica or lead base glass, color and/or opacity of the glass beads and glass samples. The result showed that Sungai Mas produced their own Indo-Pacific beads from sixth to thirteenth century AD. (author)

  11. Butyl acetate synthesis using immobilized lipase in calcium alginate beads

    International Nuclear Information System (INIS)

    Mohd Zulkhairi Abdul Rahim; Lee, Pat M.; Lee, Kong H.

    2008-01-01

    The esterification reaction of acetic acid and n-butanol using immobilized lipase encapsulated in calcium alginate beads (Lipase - CAB) and in chitosan coated calcium alginate beads (Lipase-CCAB) in n-hexane under mild reaction conditions were studied. Effects of temperature and substrate concentration (acetic acid and n-butanol) using Lipase - CAB, Lipase - CCAB and free lipase on the esterification reaction and their thermal stability towards esterification reaction were investigated. Results of temperature studies showed that the butyl acetate conversion increased with increase of temperature and reached the highest yield of about 70% around 50 degree Celsius for both immobilized systems but the yield of product catalyzed by free enzyme decreased as temperature was increased. Thermal stabilities studies showed that the Lipase-CCAB and Lipase-CAB were stable throughout the temperature range of 30-60 degree Celsius. However, free lipase became less stable at temperatures higher than 50 degree Celsius. The substrates, n-butanol and acetic acid exerted different effects on the esterification reaction and the reaction was favoured by higher acetic acid concentration than butanol. Kinetics parameters, Km and Vmax values for both substrates and the specific activities of the three enzyme system were also determined. The beads morphology was examined using SEM. Batch-wise operational stability studies for both immobilized systems demonstrated that the immobilized lipase performed better in the batch wise reactor system than the continuous bioreactor system and that the immobilized lipase remained active for at least 5 cycles of batch wise esterification reactions. (author)

  12. Preparation of porous 2,3-dialdehyde cellulose beads crosslinked with chitosan and their application in adsorption of Congo red dye.

    Science.gov (United States)

    Ruan, Chang-Qing; Strømme, Maria; Lindh, Jonas

    2018-02-01

    Micrometer sized 2,3-dialdehyde cellulose (DAC) beads were produced via a recently developed method relying on periodate oxidation of Cladophora nanocellulose. The produced dialdehyde groups and pristine hydroxyl groups provided the DAC beads with a vast potential for further functionalization. The sensitivity of the DAC beads to alkaline conditions, however, limits their possible functionalization and applications. Hence, alkaline-stable and porous cellulose beads were prepared via a reductive amination crosslinking reaction between 2,3-dialdehyde cellulose beads and chitosan. The produced materials were thoroughly characterized with different methods. The reaction conditions, including the amount of chitosan used, conditions for reductive amination, reaction temperature and time, were investigated and the maintained morphology of the beads after exposure to 1M NaOH (aq.) was verified with SEM. Different washing and drying procedures were used and the results were studied by SEM and BET analysis. Furthermore, FTIR, TGA, EDX, XPS, DLS and elemental analysis were performed to characterize the properties of the prepared beads. Finally, the alkaline-stable porous chitosan cross-linked 2,3-dialdehyde cellulose beads were applied as adsorbent for the dye Congo red. The crosslinked beads displayed fast and high adsorption capacity at pH 2 and good desorption properties at pH 12, providing a promising sorption material. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Disintegration of Nannochloropsis sp. cells in an improved turbine bead mill.

    Science.gov (United States)

    Pan, Zhidong; Huang, Ying; Wang, Yanmin; Wu, Zhiwei

    2017-12-01

    The Nannochloropsis sp. cells in aqueous solution were disintegrated in an improved bead mill with turbine agitator. The disintegration rates of cell samples disrupted under various operating parameters (i.e., circumferential speed, bead size, disintegration time, and cell concentration) were analyzed. An experimental strategy to optimize the parameters affecting the cell disintegration process was proposed. The results show that Nannochloropsis sp. cells can be effectively disintegrated in the turbine stirred bead mill under the optimum condition (i.e., circumferential speed of 2.3m/s, concentration of 15vol.%, disintegration time of 40min and bead size of 0.3-0.4mm). The disintegration mechanism was discussed via the selection and breakage functions from population balance modelling. It is revealed that the impact and compression effects of stirring beads are more effective for the disruption of coarser fraction of cells, and the shear effect dominates the production of finer fractions of disintegrated cells. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Biodegradable, pH-sensitive chitosan beads obtained under microwave radiation for advanced cell culture.

    Science.gov (United States)

    Piątkowski, Marek; Janus, Łukasz; Radwan-Pragłowska, Julia; Bogdał, Dariusz; Matysek, Dalibor

    2018-04-01

    A new type of promising chitosan beads with advanced properties were obtained under microwave radiation according to Green Chemistry principles. Biomaterials were prepared using chitosan as raw material and glutamic acid/1,5-pentanodiol mixture as crosslinking agents. Additionally beads were modified with Tilia platyphyllos extract to enhance their antioxidant properties. Beads were investigated over their chemical structure by FT-IR analysis. Also their morphology has been investigated by SEM method. Additionally swelling capacity of the obtained hydrogels was determined. Lack of cytotoxicity has been confirmed by MTT assay. Proliferation studies were carried out on L929 mouse fibroblasts. Advanced properties of the obtained beads were investigated by studying pH sensitivity and antioxidant properties by DPPH method. Also susceptibility to degradation and biodegradation by Sturm Test method was evaluated. Results shows that proposed chitosan beads and their eco-friendly synthesis method can be applied in cell therapy and tissue engineering. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. High surface area mesoporous activated carbon-alginate beads for efficient removal of methylene blue.

    Science.gov (United States)

    Nasrullah, Asma; Bhat, A H; Naeem, Abdul; Isa, Mohamed Hasnain; Danish, Mohammed

    2018-02-01

    High surface area mesoporous activated carbon-alginate (AC-alginate) beads were successfully synthesized by entrapping activated carbon powder derived from Mangosteen fruit peel into calcium-alginate beads for methylene blue (MB) removal from aqueous solution. The structure and surface characteristics of AC-alginate beads were analyzed using Fourier transform infra-red (FTIR) spectroscopy, scanning electron microscopy (SEM) and surface area analysis (S BET ), while thermal properties were tested using thermogravimetric analysis (TGA). The effect of AC-alginate dose, pH of solution, contact time, initial concentration of MB solution and temperature on MB removal was elucidated. The results showed that the maximum adsorption capacity of 230mg/g was achieved for 100mg/L of MB solution at pH 9.5 and temperature 25°C. Furthermore, the adsorption of MB on AC-alginate beads followed well pseudo-second order equation and equilibrium adsorption data were better fitted by the Freundlich isotherm model. The findings reveal the feasibility of AC-alginate beads composite to be used as a potential and low cost adsorbent for removal of cationic dyes. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Am/Cm TTR testing - 3/8-inch glass beads evaluation in CIM5

    International Nuclear Information System (INIS)

    Witt, D. C.

    2000-01-01

    To facilitate the procurement and handling of the glass former for Am/Cm vitrification in the F-Canyon MPPF, 1/4 inch and 3/8 inch diameter glass beads were purchased from Corning for evaluation in the 5 inch Cylindrical Induction Melter (CIM5). Prior to evaluating the beads in the CIM5, tests were conducted in the Drain Tube Test Stand (DTTS) with 1/4 inch beads, 3/8 inch beads, and a 50/50 mixture to identify any process concerns. Results of the DTTS tests are summarized in Attachment 1. A somewhat larger volume expansion was experienced in all three DTTS runs as compared to a standard run using cullet. Further testing of the use of glass beads in the CIM5 was requested by the Design Authority as Task 1.02 of Technical Task Request 99-MNSS/SE-006. Since the Technical Task Plan was not yet approved, the completion of this task was conducted under an authorization request approved by the SRTC Laboratory Director, S. Wood. This request is included as Attachment 2

  17. Structure of yttria stabilized zirconia beads produced by gel supported precipitation

    International Nuclear Information System (INIS)

    Walter, M.; Somers, J.; Fernandez, A.; Specht, Eliot D.; Hunn, John D.; Boulet, P.; Denecke, M. A.; Gobel, C.

    2007-01-01

    Yttria stabilized zirconia (YSZ) is one of the inert matrix candidates selected for investigation as host matrix for minor actinide (MA) transmutation. The structural properties of (Zr0.84, Y0.16)O1.92 beads prepared by a sol-gel method for MA infiltration, are characterized as calcined (850 C) and sintered (1,600 C) beads. The calcined YSZ beads are fine-grained and homogenous over the entire sphere and are surrounded by a uniform outer layer of approximately 30 (micro)m thickness. After sintering at 1,600 C, the beads are compacted to 51% of their initial volume and exhibit a granular structure. The thermal expansion is nearly linear for the calcined material, but shows a parabolic behavior for the sintered (1,400 C) beads. In addition, the thermal expansion of calcined material is 20-25% less than after sintering. During heating up to 1,400 C, two processes can be distinguished. The first occurs between 900 and 1,000 C and is related to an increase in unit cell order. The second process involves grain-growth of the less crystalline calcined material between 1,100 and 1,300 C. These results have implications for preparation of YSZ and its use as an inert MA transmutation matrix

  18. Appropriate welding conditions of temper bead weld repair for SQV2A pressure vessel steel

    International Nuclear Information System (INIS)

    Mizuno, R.; Matsuda, F.; Brziak, P.; Lomozik, M.

    2004-01-01

    Temper bead welding technique is one of the most important repair welding methods for large structures for which it is difficult to perform the specified post weld heat treatment. In this study, appropriate temper bead welding conditions to improve the characteristics of heat affected zone (HAZ) are studied using pressure vessel steel SQV2A corresponding to ASTM A533 Type B Class 1. Thermal/mechanical simulator is employed to give specimens welding thermal cycles from single to quadruple cycle. Charpy absorbed energy and hardness of simulated CGHAZ by first cycle were degraded as compared with base metal. Improvability of these degradations by subsequent cycles is discussed and appropriate temper bead thermal cycles are clarified. When the peak temperature lower than Ac1 and near Ac1 in the second thermal cycle is applied to CGAHZ by first thermal cycle, the characteristics of CGHAZ improve enough. When the other peak temperatures (that is, higher than Ac1) in the second thermal cycle are applied to the CGHAZ, third or more thermal cycle temper bead process should be applied to improve the properties. Appropriate weld condition ranges are selected based on the above results. The validity of the selected ranges is verified by the temper bead welding test. (orig.)

  19. Heat transfer enhancement in energy storage in spherical capsules filled with paraffin wax and metal beads

    International Nuclear Information System (INIS)

    Ettouney, Hisham; Alatiqi, Imad; Al-Sahali, Mohammad; Al-Hajirie, Khalida

    2006-01-01

    Energy storage is an attractive option to conserve limited energy resources, where more than 50% of the generated industrial energy is discarded in cooling water and stack gases. This study focuses on the evaluation of heat transfer enhancement in phase change energy storage units. The experiments are performed using spherical capsules filled with paraffin wax and metal beads. The experiments are conducted by inserting a single spherical capsule filled with wax and metal beads in a stream of hot/cold air. Experimental measurements include the temperature field within the spherical capsule and in the air stream. To determine the enhancement effects of the metal beads, the measured data is correlated against those for a spherical capsule filled with pure wax. Data analysis shows a reduction of 15% in the melting and solidification times upon increasing the number and diameter of the metal beads. This reduction is caused by a similar decrease in the thermal load of the sphere due to replacement of the wax by metal beads. The small size of the spherical capsule limits the enhancement effects; this is evident upon comparison of the heat transfer in a larger size, double pipe energy storage unit, where 2% of the wax volume is replaced with metal inserts, result in a three fold reduction in the melting/solidification time and a similar enhancement in the heat transfer rate

  20. Efficacy and safety of zotarolimus-eluting and sirolimus-eluting coronary stents in routine clinical care (SORT OUT III): a randomised controlled superiority trial

    DEFF Research Database (Denmark)

    Rasmussen, Klaus; Maeng, Michael; Kaltoft, Anne

    2010-01-01

    In low-risk patients, the zotarolimus-eluting stent has been shown to reduce rates of restenosis without increasing the risk of stent thrombosis. We compared the efficacy and safety of the zotarolimus-eluting stent versus the sirolimus-eluting stent in patients with coronary artery disease who we...

  1. Effects of off-specification procedures on the mechanical properties of half-bead weld repairs

    International Nuclear Information System (INIS)

    Hobson, D.O.; Nanstad, R.K.

    1983-07-01

    We examined the effects of off-specification procedures on the mechanical properties of half-bead weld repairs. The name half-bead is derived from the specification that half the thickness of the initial weld layer be ground off before the second layer is deposited. In this study the heat-affected zones of a weldment made with both all and none of the first layer removed were tested for toughness, hardness, and microstructural differences, and the results were compared with the properties of a protypical half-bead repair made under ASME Boiler and Pressure Vessel Code, Sect. XI, guidelines. The results of this limited study showed no apparent justification for the requirement to grind off half the first layer in this type of weld repair. The graded electrode sizes used to make the welds probably had more to do with the weld properties than did the range of first-layer thicknesses used in this study

  2. Feasibility study of plutonium isotopic analysis of resin beads by nondestructive gamma-ray spectroscopy

    International Nuclear Information System (INIS)

    Li, T.K.

    1985-01-01

    We have initiated a feasibility study on the use of nondestructive low-energy gamma-ray spectroscopy for plutonium isotopic analysis on resin beads. Seven resin bead samples were measured, with each sample containing an average of 9 μg of plutonium; the isotopic compositions of the samples varied over a wide range. The gamma-ray spectroscopy results, obtained from 4-h counting-time measurements, were compared with mass spectrometry results. The average ratios of gamma-ray spectroscopy to mass spectrometry were 1.014 +- 0.025 for 238 Pu/ 239 Pu, 0.996 +- 0.018 for 240 Pu/ 239 Pu, and 0.980 +- 0.038 for 241 Pu/ 239 Pu. The rapid, automated, and accurate nondestructive isotopic analysis of resin beads may be very useful to process technicians and International Atomic Energy Agency inspectors. 3 refs., 1 fig., 3 tabs

  3. Automated bead-positioning system for measuring impedances of R-F cavity modes

    International Nuclear Information System (INIS)

    Goldberg, D.A.; Rimmer, R.A.

    1993-05-01

    We describe a fully automated bead puller system which uses stepping motors to position the bead, and an HP-8510 network analyzer to measure the resulting frequency shifts, both devices being under computer control. Longitudinal motion of the bead is used for measurement of cavity shunt impedance. In addition, azimuthal scans at fixed longitudinal position aid in determining the multipole character of higher-order modes. High sensitivity/accuracy is made possible by measuring phase shifts at the unperturbed resonant frequencies (rather than frequency shifts themselves), thereby permitting averaging factors of > 500 with only modest increases in data acquisition time. Sample measurements will be presented. A comprehensive analysis of the experimental results is presented in an accompanying paper

  4. Numerical Modelling of Insulin and Amyloglucosidase Release from Swelling Ca-Alginate Beads

    DEFF Research Database (Denmark)

    Rasmussen, Michael R.; Snabe, T.; Pedersen, Lars Haastrup

    2003-01-01

    The release of insulin hexamer (39 kD) and amyloglucosidase (AMG, 97 kD), entrapped in spherical Ca–alginate beads, was investigated. While the release of insulin could be described solely by diffusion this was not the case for the 1.6 (r m /r m) larger AMG protein, where rm is the Stokes....... Although it should be expected that the effective diffusion coefficient of AMG is only slightly lower than that of insulin, the results show that the effective diffusions coefficient of AMG was found to be much smaller. In the case of AMG, it was shown that including bead size changes and the resulting...

  5. Bioresorbable polymer coated drug eluting stent: a model study.

    Science.gov (United States)

    Rossi, Filippo; Casalini, Tommaso; Raffa, Edoardo; Masi, Maurizio; Perale, Giuseppe

    2012-07-02

    In drug eluting stent technologies, an increased demand for better control, higher reliability, and enhanced performances of drug delivery systems emerged in the last years and thus offered the opportunity to introduce model-based approaches aimed to overcome the remarkable limits of trial-and-error methods. In this context a mathematical model was studied, based on detailed conservation equations and taking into account the main physical-chemical mechanisms involved in polymeric coating degradation, drug release, and restenosis inhibition. It allowed highlighting the interdependence between factors affecting each of these phenomena and, in particular, the influence of stent design parameters on drug antirestenotic efficacy. Therefore, the here-proposed model is aimed to simulate the diffusional release, for both in vitro and the in vivo conditions: results were verified against various literature data, confirming the reliability of the parameter estimation procedure. The hierarchical structure of this model also allows easily modifying the set of equations describing restenosis evolution to enhance model reliability and taking advantage of the deep understanding of physiological mechanisms governing the different stages of smooth muscle cell growth and proliferation. In addition, thanks to its simplicity and to the very low system requirements and central processing unit (CPU) time, our model allows obtaining immediate views of system behavior.

  6. Studies on DNA damage: discordant responses of rate of DNA disentanglement (viscosimetrically evaluated) and alkaline elution rate, obtained for several compounds. Possible explanations of the discrepancies.

    Science.gov (United States)

    Parodi, S; Balbi, C; Abelmoschi, M L; Pala, M; Russo, P; Santi, L

    1983-12-01

    Alkaline elution is a well-known method for detecting DNA damage. Recently we have developed a viscosimetric method that is even more sensitive than alkaline elution. Here we report that the two methods, although apparently both revealing alkaline DNA fragmentation, can give dramatically different results for a significant series of compounds. We suspect that alkaline elution might reveal not only DNA fragmentation but also the extent of disentanglement of chromatin structure, whereas this DNA disentanglement rate, when evaluated viscosimetrically , is more strictly correlated with the initiation of DNA unwinding.

  7. HPMA and HEMA copolymer bead interactions with eukaryotic cells

    Directory of Open Access Journals (Sweden)

    Cristina D. Vianna-Soares

    2004-09-01

    Full Text Available Two different hydrophilic acrylate beads were prepared via aqueous suspension polymerization. Beads produced of a hydroxypropyl methacrylate (HPMA and ethyleneglycol methacrylate (EDMA copolymer were obtained using a polyvinyl alcohol suspending medium. Copolymers of 2hydroxyethyl methacrylate (HEMA, methyl methacrylate (MMA and ethyleneglycol methacrylate (EDMA beads were obtained using magnesium hydroxide as the suspending agent. Following characterization by scanning electron microscopy (SEM, nitrogen sorption analysis (NSA and mercury intrusion porosimetry (MIP, the beads were cultured with monkey fibroblasts (COS7 to evaluate their ability to support cell growth, attachment and adhesion. Cell growth behavior onto small HPMA/EDMA copolymer beads and large HEMA/MMA/EDMA copolymer beads is evaluated regarding their hidrophilicity/hidrophobicity and surface roughness.

  8. Microarray of DNA probes on carboxylate functional beads surface

    Institute of Scientific and Technical Information of China (English)

    黄承志; 李原芳; 黄新华; 范美坤

    2000-01-01

    The microarray of DNA probes with 5’ -NH2 and 5’ -Tex/3’ -NH2 modified terminus on 10 um carboxylate functional beads surface in the presence of 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDC) is characterized in the preseni paper. it was found that the microarray capacity of DNA probes on the beads surface depends on the pH of the aqueous solution, the concentra-tion of DNA probe and the total surface area of the beads. On optimal conditions, the minimum distance of 20 mer single-stranded DNA probe microarrayed on beads surface is about 14 nm, while that of 20 mer double-stranded DNA probes is about 27 nm. If the probe length increases from 20 mer to 35 mer, its microarray density decreases correspondingly. Mechanism study shows that the binding mode of DNA probes on the beads surface is nearly parallel to the beads surface.

  9. Microarray of DNA probes on carboxylate functional beads surface

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The microarray of DNA probes with 5′-NH2 and 5′-Tex/3′-NH2 modified terminus on 10 m m carboxylate functional beads surface in the presence of 1-ethyl-3-(3-dimethylaminopropyl)- carbodiimide (EDC) is characterized in the present paper. It was found that the microarray capacity of DNA probes on the beads surface depends on the pH of the aqueous solution, the concentration of DNA probe and the total surface area of the beads. On optimal conditions, the minimum distance of 20 mer single-stranded DNA probe microarrayed on beads surface is about 14 nm, while that of 20 mer double-stranded DNA probes is about 27 nm. If the probe length increases from 20 mer to 35 mer, its microarray density decreases correspondingly. Mechanism study shows that the binding mode of DNA probes on the beads surface is nearly parallel to the beads surface.

  10. Magmaris: a new generation metallic sirolimus-eluting fully bioresorbable scaffold: present status and future perspectives

    OpenAIRE

    Rapetto, Claudio; Leoncini, Massimo

    2017-01-01

    Drug-eluting stents (DES) have reached a high safety and efficacy profile, becoming the best option for percutaneous coronary interventions (PCI) based revascularization. However, despite their optimal performance, a few concerns remain regarding their use, mainly due to permanent caging of the vessels and its consequences, first of all late stent thrombosis (ST). Bioresorbable scaffolds (BRS) aim to overcome these issues. The results achieved in randomized controlled trials (RCT) by the firs...

  11. Self-Assembled Polystyrene Beads for Templated Covalent Functionalization of Graphitic Substrates Using Diazonium Chemistry.

    Science.gov (United States)

    Van Gorp, Hans; Walke, Peter; Bragança, Ana M; Greenwood, John; Ivasenko, Oleksandr; Hirsch, Brandon E; De Feyter, Steven

    2018-04-11

    A network of self-assembled polystyrene beads was employed as a lithographic mask during covalent functionalization reactions on graphitic surfaces to create nanocorrals for confined molecular self-assembly studies. The beads were initially assembled into hexagonal arrays at the air-liquid interface and then transferred to the substrate surface. Subsequent electrochemical grafting reactions involving aryl diazonium molecules created covalently bound molecular units that were localized in the void space between the nanospheres. Removal of the bead template exposed hexagonally arranged circular nanocorrals separated by regions of chemisorbed molecules. Small molecule self-assembly was then investigated inside the resultant nanocorrals using scanning tunneling microscopy to highlight localized confinement effects. Overall, this work illustrates the utility of self-assembly principles to transcend length scale gaps in the development of hierarchically patterned molecular materials.

  12. Applied Study on Magnetic Nanometer Beads in Preparation of Genechip Samples

    Institute of Scientific and Technical Information of China (English)

    陈慧; 高华方; 谢欣; 马雪梅; 杨渝珍

    2004-01-01

    Summary: A protocol for enrichment and adsorption of karyocyte from whole blood by using magnetic nanometer beads as solid-phase absorbents was presented. The PCR amplification could be accomplished by using the nanobeads with karyocyte as template directly and the PCR products were applied on an oligonucleotide array to do gene typing. The HLA-A PCR amplification system and a small HLA-A oligonucleotide microarray were applied as the platform and an experiment protocol of separating karyocyte from whole blood using the magnetic nanometer beads (Fe2O3) were set up.The experimental conditions were also discussed. It showed that pH level of PBS eluent, Taq enzyme quantity and fragment length of products could influent the amplification results, and the magnetic nano-beads could succeed in sample preparation in microarray to provide a promising way in automatic detection and lab-on-a-chip.

  13. Isotopic measurement of uranium using NP-type chelate resin beads

    International Nuclear Information System (INIS)

    Wu Lanbi; Chen Wenpo; Wang Shijun

    1994-08-01

    NP-type chelate resin beads is used as a carrier of samples in the isotopic measurements of uranium by mass spectrometry. The results show that its absorption efficiency for uranium can be greater than 50%. It is one order magnitude higher than that strong basic anion resin, however, the ionization efficiencies of both are almost the same. Therefore, the amount of uranium required for isotopic analysis can be reduced one order of magnitude. This method has been used for isotopic analysis of uranium in NP-type chelate resin beads contained 10 -9 ∼ 10 -7 g uranium. For standard sample UTB-500, the external precision of measurements are within +-0.2%, for natural uranium samples are within +- 0.5%. The application of NP-type chelate resin beads in the isotopic measurement of uranium is a new creative achievement. It has been used in the depletion test of uranium-atomic vapor laser isotope separation

  14. Biosorption of strontium ions from aqueous solution using Ca-alginate biopolymer beads

    International Nuclear Information System (INIS)

    Goek, C.; Aytas, S.; Gerstmann, U.

    2009-01-01

    Biosorption of strontium ions from aqueous solution onto calcium alginate biopolymer beads was investigated in a batch system. Ca-alginate biopolymer beads were prepared from Na-alginate via cross-linking with divalent calcium ions according to the egg box model. Optimum biosorption conditions were determined as a function of initial solution pH, initial Sr concentration, contact time, biomass dosage and temperature. Langmuir, Freundlich and Dubinin-Radushkevich (D-R) models were applied to describe the biosorption isotherm of Sr ions by Ca-alginate biopolymer beads. The thermodynamic parameters (ΔH, ΔS, ΔG) for Sr sorption onto biosorbent were also determined from the temperature dependence. The results indicate that this biosorbent has a good potential for removal of Sr ions from dilute aqueous solution.

  15. Analysis of early medieval glass beads - Glass in the transition period

    Energy Technology Data Exchange (ETDEWEB)

    Smit, Ziga, E-mail: ziga.smit@ijs.si [Faculty of Mathematics and Physics, University of Ljubljana, Jadranska 19, SI-1000 Ljubljana (Slovenia); Jozef Stefan Institute, Jamova 39, P.O.B. 3000, SI-1001 Ljubljana (Slovenia); Knific, Timotej [National Museum of Slovenia, Presernova 20, SI-1000 Ljubljana (Slovenia); Jezersek, David [Jozef Stefan Institute, Jamova 39, P.O.B. 3000, SI-1001 Ljubljana (Slovenia); Istenic, Janka [National Museum of Slovenia, Presernova 20, SI-1000 Ljubljana (Slovenia)

    2012-05-01

    Glass beads from graves excavated in Slovenia and dated archaeologically to the 7th-10th century AD were analysed by the combined PIXE-PIGE method. The results indicate two groups of glass; natron glass made in the Roman tradition and glass made with alkalis from the ash of halophytic plants, which gradually replaced natron glass after c. 800 AD. The alkalis used in the second group of glass seem to be in close relation to a variant of the Venetian white glass that appeared several centuries later. The origin of this glass may be traced to glass production in Mesopotamia and around the Aral Sea. All the mosaic beads with eye decoration, as well as most of the drawn-segmented and drawn-cut beads analysed, are of plant-ash glass, which confirms their supposed oriental origin.

  16. Solid phase extraction of penicillins from milk by using sacrificial silica beads as a support for a molecular imprint

    International Nuclear Information System (INIS)

    Giovannoli, Cristina; Anfossi, Laura; Biagioli, Flavia; Passini, Cinzia; Baggiani, Claudio

    2013-01-01

    We have prepared molecularly imprinted beads with molecular recognition capability for target molecules containing the penicillanic acid substructure. They were prepared by (a) grafting mesoporous silica beads with 6-aminopenicillanic acid as the mimic template, (b) filling the pores with a polymerized mixture of methacrylic acid and trimethylolpropane trimethacrylate, and (c) removing the silica support with ammonium fluoride. The resulting imprinted beads showed good molecular recognition capability for various penicillanic species, while antibiotics such as cephalosporins or chloramphenicol were poorly recognized. The imprinted beads were used to extract penicillin V, nafcillin, oxacillin, cloxacillin and dicloxacillin from skimmed and deproteinized milk in the concentration range of 5–100 μg·L −1 . The extracts were then analyzed by micellar electrokinetic chromatography by applying reverse polarity staking as an in-capillary preconcentration step, and this resulted in a fast and affordable method within the MRL levels, characterized by minimal pretreatment steps and recoveries of 64–90 %. (author)

  17. Detection of ''beading faults'' in welded tubes

    International Nuclear Information System (INIS)

    Mondot, J.

    In the steel tube industry the word ''beading'' refers to a highly localised leak affecting the welded zone. During the pneumatic test its flow rate is generally very low no more than a few thousandths of a mm 3 /second. Detection of such a fault by this test is consequently slow, and those which are choked or at the limit of leakage may escape detection. For greater safety, the tube technician is now using non-destructive testing methods such as eddy-currents and ultrasonics [fr

  18. Advantages of novel BioMimeTM Sirolimus Eluting Coronary Stent system. Moving towards biomimicry.

    Science.gov (United States)

    Upendra, K; Sanjeev, B

    2012-02-01

    Since the first reported use of percutaneous transluminal coronary angioplasty (PTCA), advancements in interventional cardiology arena have been fast paced. Within the last ten years, these developments have been exponential. Developers & clinicians are fast adapting from the learning curve awarded by the time course of DES evolution. In that light BioMimeTM Sirolimus Eluting Coronary Stent comes as a fresh thought in taking stents towards a biomimicry concept. The stent is built on an ultra-low strut thickness (65 µm) cobalt chromium stent platform, using an intelligent hybrid of close and open cells allowing for morphology mediated expansion, employs a well known anti-proliferative - Sirolimus that elutes from a biodegradable co-polymer formulation in 30 days and ensures high coating integrity and low coating thickness of 2 µm. The resultant stent demonstrates almost 100% endothelialization at 30 days in preclinical model and zero percent MACE >18 months in the primary efficacy and safety clinical study.

  19. Creating nanoshell on the surface of titanium hydride bead

    Directory of Open Access Journals (Sweden)

    PAVLENKO Vyacheslav Ivanovich

    2016-12-01

    Full Text Available The article presents data on the modification of titanium hydride bead by creating titanium nanoshell on its surface by ion-plasma vacuum magnetron sputtering. To apply titanium nanoshell on the titanium hydride bead vacuum coating plant of multifunctional nanocomposite coatings QVADRA 500 located in the center of high technology was used. Analysis of the micrographs of the original surface of titanium hydride bead showed that the microstructure of the surface is flat, smooth, in addition the analysis of the microstructure of material surface showed the presence of small porosity, roughness, mainly cavities, as well as shallow longitudinal cracks. The presence of oxide film in titanium hydride prevents the free release of hydrogen and fills some micro-cracks on the surface. Differential thermal analysis of both samples was conducted to determine the thermal stability of the initial titanium hydride bead and bead with applied titanium nanoshell. Hydrogen thermal desorption spectra of the samples of the initial titanium hydride bead and bead with applied titanium nanoshell show different thermal stability of compared materials in the temperature range from 550 to 860о C. Titanium nanoshells applied in this way allows increasing the heat resistance of titanium hydride bead – the temperature of starting decomposition is 695о C and temperature when decomposition finishes is more than 1000о C. Modified in this way titanium hydride bead can be used as a filler in the radiation protective materials used in the construction or upgrading biological protection of nuclear power plants.

  20. First-in-human evaluation of a bioabsorbable polymer-coated sirolimus-eluting stent: imaging and clinical results of the DESSOLVE I Trial (DES with sirolimus and a bioabsorbable polymer for the treatment of patients with de novo lesion in the native coronary arteries).

    Science.gov (United States)

    Ormiston, John; Webster, Mark; Stewart, James; Vrolix, Mathias; Whitbourn, Robert; Donohoe, Dennis; Knape, Charlene; Lansky, Alexandra; Attizzani, Guilherme F; Fitzgerald, Peter; Kandzari, David E; Wijns, William

    2013-10-01

    This first-in-human multicenter study sought to examine prospectively the safety and efficacy of a new, cobalt chromium thin-strut, coronary absorbable polymer-coated, sirolimus-eluting stent. Bioabsorbable polymers on drug-eluting stents may lower the long-term risks of inflammation, delayed healing, and adverse events. We enrolled patients with symptomatic coronary artery disease with stable or unstable angina pectoris and >50% diameter stenosis, amenable to coverage with a ≤23-mm long stent in a vessel 2.5 to 3.5 mm in diameter. All patients received dual antiplatelet therapy after implantation. Patients, in groups of 10, underwent repeat angiography, intravascular ultrasound, and optical coherence tomography at 4, 6, or 8 months, and all patients were seen or contacted at 18 months of follow-up. The median (range) in-stent late lumen loss (LLL) was 0.03 mm (-0.22 to 0.21 mm), 0.10 mm (-0.03 to 1.2 mm), and 0.08 mm (-0.01 to 0.28 mm), at 4, 6, and 8 months, respectively. At 18 months, the median in-stent LLL was 0.08 mm (-0.30 to 0.46 mm). On optical coherence tomography, the proportion of uncovered stent struts decreased from a median of 7.3% (range 0.4% to 46.3%) at 4 months to 0% (range: 0% to 3.4%) at 18 months. The percentage of neointimal volume obstruction by intravascular ultrasound increased from a median of 5.3% to 9.1% between 4 and 6 months and remained nearly unchanged thereafter through 18 months of follow-up. The only recorded major adverse cardiac event was a myocardial infarction. At 18 months of follow-up, this absorbable polymer-coated, cobalt chromium sirolimus-eluting stent was associated with a low and stable in-stent LLL, complete strut coverage, and no stent thrombosis. (First-In-Human Trial of the MiStent Drug-Eluting Stent [DES] in Coronary Artery Disease [DESSOLVE-I]; NCT01247428). Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  1. Long-term efficacy and safety of biodegradable-polymer biolimus-eluting stents: main results of the Basel Stent Kosten-Effektivitäts Trial-PROspective Validation Examination II (BASKET-PROVE II), a randomized, controlled noninferiority 2-year outcome trial.

    Science.gov (United States)

    Kaiser, Christoph; Galatius, Soeren; Jeger, Raban; Gilgen, Nicole; Skov Jensen, Jan; Naber, Christoph; Alber, Hannes; Wanitschek, Maria; Eberli, Franz; Kurz, David J; Pedrazzini, Giovanni; Moccetti, Tiziano; Rickli, Hans; Weilenmann, Daniel; Vuillomenet, André; Steiner, Martin; Von Felten, Stefanie; Vogt, Deborah R; Wadt Hansen, Kim; Rickenbacher, Peter; Conen, David; Müller, Christian; Buser, Peter; Hoffmann, Andreas; Pfisterer, Matthias

    2015-01-06

    Biodegradable-polymer drug-eluting stents (BP-DES) were developed to be as effective as second-generation durable-polymer drug-eluting stents (DP-DES) and as safe >1 year as bare-metal stents (BMS). Thus, very late stent thrombosis (VLST) attributable to durable polymers should no longer appear. To address these early and late aspects, 2291 patients presenting with acute or stable coronary disease needing stents ≥3.0 mm in diameter between April 2010 and May 2012 were randomly assigned to biolimus-A9-eluting BP-DES, second-generation everolimus-eluting DP-DES, or thin-strut silicon-carbide-coated BMS in 8 European centers. All patients were treated with aspirin and risk-adjusted doses of prasugrel. The primary end point was combined cardiac death, myocardial infarction, and clinically indicated target-vessel revascularization within 2 years. The combined secondary safety end point was a composite of VLST, myocardial infarction, and cardiac death. The cumulative incidence of the primary end point was 7.6% with BP-DES, 6.8% with DP-DES, and 12.7% with BMS. By intention-to-treat BP-DES were noninferior (predefined margin, 3.80%) compared with DP-DES (absolute risk difference, 0.78%; -1.93% to 3.50%; P for noninferiority 0.042; per protocol P=0.09) and superior to BMS (absolute risk difference, -5.16; -8.32 to -2.01; P=0.0011). The 3 stent groups did not differ in the combined safety end point, with no decrease in events >1 year, particularly VLST with BP-DES. In large vessel stenting, BP-DES appeared barely noninferior compared with DP-DES and more effective than thin-strut BMS, but without evidence for better safety nor lower VLST rates >1 year. Findings challenge the concept that durable polymers are key in VLST formation. http://www.clinicaltrials.gov. Unique identifier: NCT01166685. © 2014 American Heart Association, Inc.

  2. The Numerical Welding Simulation - Developments and Validation of Simplified and Bead Lumping Methods

    International Nuclear Information System (INIS)

    Baup, Olivier

    2001-01-01

    The aim of this work was to study the TIG multipass welding process on stainless steel, by means of numerical methods and then to work out simplified and bead lumping methods in order to reduce adjusting and realisation times of these calculations. A simulation was used as reference for the validation of these methods; after the presentation of the test series having led to the option choices of this calculation (2D generalised plane strains, elastoplastic model with an isotropic hardening, hardening restoration due to high temperatures), various simplifications were tried on a plate geometry. These simplifications related various modelling points with a correct plastic flow representation in the plate. The use of a reduced number of thermal fields characterising the bead deposit and a low number of tensile curves allow to obtain interesting results, decreasing significantly the Computing times. In addition various lumping bead methods have been studied and concerning both the shape and the thermic of the macro-deposits. The macro-deposit shapes studied are in 'L', or in layer or they represent two beads one on top of the other. Among these three methods, only those using a few number of lumping beads gave bad results since thermo-mechanical history was deeply modified near and inside the weld. Thereafter, simplified methods have been applied to a tubular geometry. On this new geometry, experimental measurements were made during welding, which allow a validation of the reference calculation. Simplified and reference calculations gave approximately the same stress fields as found on plate geometry. Finally, in the last part of this document a procedure for automatic data setting permitting to reduce significantly the calculation phase preparation is presented. It has been applied to the calculation of thick pipe welding in 90 beads; the results are compared with a simplified simulation realised by Framatome and with experimental measurements. A bead by

  3. Preparation of Immuno-magnetic Beads and Their Separation & Detection to Ovary Cancer Cells

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The organic monomer-molecule with nanometer magnetic powder by means of reforming the surface of nanometer magnetic powder have been synthesized.Magnetic beads in diameter of 2μm or so are obtained by controlling conditions.Ovary cancer cells of ascites are separated and ovary cancer cells of blood are detected by using immuno-magnetic beads linked with ovary cancer cell mono-antibodies.Results show that the specificity is 85%,sensitivity is 87%,accuracy is 84%,cells acquiring purity is 90%,cells activity is 92% and detection sensitivity is 25×10-7.

  4. Beads task vs. box task: The specificity of the jumping to conclusions bias.

    Science.gov (United States)

    Balzan, Ryan P; Ephraums, Rachel; Delfabbro, Paul; Andreou, Christina

    2017-09-01

    Previous research involving the probabilistic reasoning 'beads task' has consistently demonstrated a jumping-to-conclusions (JTC) bias, where individuals with delusions make decisions based on limited evidence. However, recent studies have suggested that miscomprehension may be confounding the beads task. The current study aimed to test the conventional beads task against a conceptually simpler probabilistic reasoning "box task" METHODS: One hundred non-clinical participants completed both the beads task and the box task, and the Peters et al. Delusions Inventory (PDI) to assess for delusion-proneness. The number of 'draws to decision' was assessed for both tasks. Additionally, the total amount of on-screen evidence was manipulated for the box task, and two new box task measures were assessed (i.e., 'proportion of evidence requested' and 'deviation from optimal solution'). Despite being conceptually similar, the two tasks did not correlate, and participants requested significantly less information on the beads task relative to the box task. High-delusion-prone participants did not demonstrate hastier decisions on either task; in fact, for box task, this group was observed to be significantly more conservative than low-delusion-prone group. Neither task was incentivized; results need replication with a clinical sample. Participants, and particularly those identified as high-delusion-prone, displayed a more conservative style of responding on the novel box task, relative to the beads task. The two tasks, whilst conceptually similar, appear to be tapping different cognitive processes. The implications of these results are discussed in relation to the JTC bias and the theoretical mechanisms thought to underlie it. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Spatially monitoring oxygen level in 3D microfabricated cell culture systems using optical oxygen sensing beads.

    Science.gov (United States)

    Wang, Lin; Acosta, Miguel A; Leach, Jennie B; Carrier, Rebecca L

    2013-04-21

    Capability of measuring and monitoring local oxygen concentration at the single cell level (tens of microns scale) is often desirable but difficult to achieve in cell culture. In this study, biocompatible oxygen sensing beads were prepared and tested for their potential for real-time monitoring and mapping of local oxygen concentration in 3D micro-patterned cell culture systems. Each oxygen sensing bead is composed of a silica core loaded with both an oxygen sensitive Ru(Ph2phen3)Cl2 dye and oxygen insensitive Nile blue reference dye, and a poly-dimethylsiloxane (PDMS) shell rendering biocompatibility. Human intestinal epithelial Caco-2 cells were cultivated on a series of PDMS and type I collagen based substrates patterned with micro-well arrays for 3 or 7 days, and then brought into contact with oxygen sensing beads. Using an image analysis algorithm to convert florescence intensity of beads to partial oxygen pressure in the culture system, tens of microns-size oxygen sensing beads enabled the spatial measurement of local oxygen concentration in the microfabricated system. Results generally indicated lower oxygen level inside wells than on top of wells, and local oxygen level dependence on structural features of cell culture surfaces. Interestingly, chemical composition of cell culture substrates also appeared to affect oxygen level, with type-I collagen based cell culture systems having lower oxygen concentration compared to PDMS based cell culture systems. In general, results suggest that oxygen sensing beads can be utilized to achieve real-time and local monitoring of micro-environment oxygen level in 3D microfabricated cell culture systems.

  6. Type D personality predicts chronic anxiety following percutaneous coronary intervention in the drug-eluting stent era

    DEFF Research Database (Denmark)

    Spindler, Helle; Pedersen, Susanne S.; Serruys, Patrick W.

    2007-01-01

      Background: Anxiety is an often overlooked risk factor in coronary artery disease (CAD). Hence, little is known about predictors of unremitting chronic anxiety in CAD patients. This study examined whether the distressed personality (Type D) predicts chronic anxiety post percutaneous coronary...... months post-PCI. Results: Of 167 patients anxious at 6 months, 108 (65%) were still anxious 12 months post-PCI. Significant univariable predictors of chronic anxiety were Type D personality (OR:3.17: 95% CI:1.64-6.14) and sirolimus-eluting stents (OR:0.51; 95% CI:0.27-0.98), with sirolimus-eluting stents...... showing a protective effect. In multivariable analyses, Type D personality (OR:3.31; 95% CI:1.59-6.87) and sirolimus-eluting stents (OR:0.44; 95% CI:0.21-0.92) remained significant independent predictors of chronic anxiety adjusting for depressive symptoms at 6 months, and demographic and clinical risk...

  7. Development of epigallocatechin gallate-eluting polymeric stent and its physicochemical, biomechanical and biological evaluations

    International Nuclear Information System (INIS)

    Han, Dong-Wook; Lee, Jun Jae; Jung, Duk-Young; Park, Jong-Chul; Hyon, Suong-Hyu

    2009-01-01

    Localized drug delivery from drug-eluting stents has been accepted as one of the most promising treatment methods for preventing restenosis after stenting. However, hypersensitivity reactions caused by their nonresorbable polymer coatings and bare-metal stents may result in serious clinical sequelae. Epigallocatechin-3-O-gallate (EGCG), the predominant catechin from tea, has been shown to exert anti-thrombotic, anti-inflammatory and anti-proliferative activities. In this study, it was hypothesized that sustainedly released EGCG from biodegradable poly(lactide-co-ε-caprolactone, PLCL) would suppress the proliferation of vascular smooth muscle cells (VSMCs). EGCG-releasing PLCL (E-PLCL) was prepared by blending PLCL with EGCG. The surface morphology, roughness and melting temperature of PLCL were not changed despite EGCG addition. EGCG was uniformly dispersed into E-PLCL and sustainedly released for periods up to 7 days by controlled diffusion rather than PLCL degradation. Moreover, EGCG did not affect tensile strength at break, but significantly increased the elastic modulus of PLCL. The proliferation of VSMCs onto E-PLCL was significantly suppressed although the cell attachment onto E-PLCL had been higher than that onto PLCL. On the other hand, EGCG-eluting polymeric stents were prepared with neither cracks nor webbings between struts, and their structural integrity was maintained without delamination or destruction. These results suggest that E-PLCL can be potentially applied for fabricating an EGCG-eluting vascular stent, namely an EGCG-eluting polymeric stent, or even an EGCG-releasing polymer-coated metal stent, to prevent thrombosis, inflammation and in-stent restenosis.

  8. Development of epigallocatechin gallate-eluting polymeric stent and its physicochemical, biomechanical and biological evaluations

    Energy Technology Data Exchange (ETDEWEB)

    Han, Dong-Wook [Department of Nanomedical Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan 609-735 (Korea, Republic of); Lee, Jun Jae [Division of Advanced Fibro-Science, Kyoto Institute of Technology, Kyoto 606-8585 (Japan); Jung, Duk-Young [Senior Products Industrial Center, Busan Techno-Park, Busan-617-030 (Korea, Republic of); Park, Jong-Chul [Cellbiocontrol Laboratory, Department of Medical Engineering, Yonsei University College of Medicine, Seoul 120-752 (Korea, Republic of); Hyon, Suong-Hyu, E-mail: nanohan@pusan.ac.k, E-mail: biogen@frontier.kyoto-u.ac.j [Department of Medical Simulation Engineering, Institute for Frontier Medical Sciences, Kyoto University, Kyoto 606-8507 (Japan)

    2009-08-15

    Localized drug delivery from drug-eluting stents has been accepted as one of the most promising treatment methods for preventing restenosis after stenting. However, hypersensitivity reactions caused by their nonresorbable polymer coatings and bare-metal stents may result in serious clinical sequelae. Epigallocatechin-3-O-gallate (EGCG), the predominant catechin from tea, has been shown to exert anti-thrombotic, anti-inflammatory and anti-proliferative activities. In this study, it was hypothesized that sustainedly released EGCG from biodegradable poly(lactide-co-epsilon-caprolactone, PLCL) would suppress the proliferation of vascular smooth muscle cells (VSMCs). EGCG-releasing PLCL (E-PLCL) was prepared by blending PLCL with EGCG. The surface morphology, roughness and melting temperature of PLCL were not changed despite EGCG addition. EGCG was uniformly dispersed into E-PLCL and sustainedly released for periods up to 7 days by controlled diffusion rather than PLCL degradation. Moreover, EGCG did not affect tensile strength at break, but significantly increased the elastic modulus of PLCL. The proliferation of VSMCs onto E-PLCL was significantly suppressed although the cell attachment onto E-PLCL had been higher than that onto PLCL. On the other hand, EGCG-eluting polymeric stents were prepared with neither cracks nor webbings between struts, and their structural integrity was maintained without delamination or destruction. These results suggest that E-PLCL can be potentially applied for fabricating an EGCG-eluting vascular stent, namely an EGCG-eluting polymeric stent, or even an EGCG-releasing polymer-coated metal stent, to prevent thrombosis, inflammation and in-stent restenosis.

  9. Histologic Assessment of Drug-Eluting Grafts Related to Implantation Site

    Directory of Open Access Journals (Sweden)

    Jean-Christophe Tille

    2016-02-01

    Full Text Available Drug-eluting vascular prostheses represent a new direction in vascular surgery to reduce early thrombosis and late intimal hyperplasia for small calibre grafts. Subcutaneous implantation in rats is a rapid and cost-effective screening model to assess the drug-elution effect and could, to some extent, be useful to forecast results for vascular prostheses. We compared biological and histological responses to scaffolds in different implantation sites. Polycaprolactone (PCL, paclitaxel-loaded PCL (PCL-PTX and dexamethasone-loaded PCL (PCL-DXM electrospun scaffolds were implanted subcutaneously and in an infrarenal abdominal aortic model in rats for up to 12 weeks. At the conclusion of the study, a histological analysis was performed. Cellular graft invasion revealed differences in the progression of cellular infiltration between PCL-PTX and PCL/PCL-DXM groups in both models. Cell infiltration increased over time in the aortic model compared to the subcutaneous model for all groups. Cell counting revealed major differences in fibroblast, macrophage and giant cell graft colonisation in all groups and models over time. Macrophages and giant cells increased in the PCL aortic model; whereas in the subcutaneous model these cell types increased only after three weeks or even decreased in the drug-eluting PCL groups. Other major findings were observed only in the aortic replacement such as extracellular matrix deposition and neo-angiogenesis. The subcutaneous implant model can be used for screening, especially when drug-eluting effects are studied. However, major histological differences were observed in cell type reaction and depth of cell penetration compared to the aortic model. Our results demonstrate that the implantation site is a critical determinant of the biological response.

  10. Investigation of Processes Controlling Elution of Solutes from Nonaqueous Phase Liquid (NAPL) Pools into Groundwater

    Science.gov (United States)

    Seyedabbasi, M.; Pirestani, K.; Holland, S. B.; Imhoff, P. T.

    2005-12-01

    Two major processes influencing the elution of solutes from porous media contaminated with nonaqueous phase liquids (NAPLs) are external mass transfer between the NAPL and groundwater and internal diffusion through NAPL ganglia and pools. There is a relatively large body of literature on the dissolution of single-species NAPLs. Less is known about the rates of elution of compounds dissolving from multicomponent NAPLs. We examined the mass transfer of one solute, 2,3-dimethyl-2-butanol (DMB) - a partitioning tracer, between groundwater and a dense NAPL - trichloroethylene (TCE). Diffusion cell experiments were used to measure the molecular diffusion coefficient of DMB in pure TCE and in porous media contaminated with a TCE pool. Measured diffusion coefficients were compared with empirical correlations (pure TCE) and a parallel resistance model (TCE pool). Based on the results from these analyses, a dimensionless Biot number was derived to express the ratio of the external rate of mass transfer from a NAPL pool to the internal rate of diffusion within the pool, which varies with NAPL saturation and NAPL-water partition coefficient. Biot numbers were then estimated for several laboratory scale experiments involving DMB transport between NAPL pools and groundwater. The estimated Biot numbers were in good agreement with experimental results. The expression for the Biot number developed here may be used to assess the processes controlling the elution of solutes from NAPL pools, which has implications on long-term predictions of solute dissolution from NAPLs in the field.

  11. Combination of maghemite and titanium oxide nanoparticles in polyvinyl alcohol-alginate encapsulated beads for cadmium ions removal

    Energy Technology Data Exchange (ETDEWEB)

    Majidnia, Zohreh; Idris, Ani [Universiti Teknologi Malaysia, johor bahru (Malaysia)

    2015-06-15

    Both maghemite (γ-Fe{sub 2}O{sub 3}) and titanium oxide (TiO{sub 2}) nanoparticles were mixed at various ratios and embedded in polyvinyl alcohol (PVA)-alginate beads. These beads were tested for photocatalytic behavior in eliminating toxic Cd(Ⅱ) from the aqueous solution. The photocatalytic experiments were performed under sunlight irradiation at various pH, initial feed concentrations and γ-Fe{sub 2}O{sub 3}: TiO{sub 2} ratios. The recycling attribute of these beads was also investigated. The results revealed that 100% of the Cd(Ⅱ) was eliminated in 150 minutes at pH 7 under sunlight. It shows that maghemite and titania PVA-alginate beads can be readily isolated from the aqueous solution after the photocatalyst process and reused for at least six times without losing their initial properties.

  12. Efficacy and Safety of Drug-Eluting Stents in the Real World: 8-Year Follow-Up

    Energy Technology Data Exchange (ETDEWEB)

    Pellegrini, Denise Oliveira, E-mail: dennizmo@yahoo.com.br; Gomes, Vitor Osório; Lasevitch, Ricardo; Smidt, Luis; Azeredo, Marco Aurélio; Ledur, Priscila; Bodanese, Rodrigo; Sinnott, Leonardo; Moriguchi, Emílio; Caramori, Paulo [Hospital São Lucas PUC, Porto Alegre, RS (Brazil)

    2014-09-15

    Drug-eluting stents have been used in daily practice since 2002, with the clear advantages of reducing the risk of target vessel revascularization and an impressive reduction in restenosis rate by 50%-70%. However, the occurrence of a late thrombosis can compromise long-term results, particularly if the risks of this event were sustained. In this context, a registry of clinical cases gains special value. To evaluate the efficacy and safety of drug-eluting stents in the real world. We report on the clinical findings and 8-year follow-up parameters of all patients that underwent percutaneous coronary intervention with a drug-eluting stent from January 2002 to April 2007. Drug-eluting stents were used in accordance with the clinical and interventional cardiologist decision and availability of the stent. A total of 611 patients were included, and clinical follow-up of up to 8 years was obtained for 96.2% of the patients. Total mortality was 8.7% and nonfatal infarctions occurred in 4.3% of the cases. Target vessel revascularization occurred in 12.4% of the cases, and target lesion revascularization occurred in 8% of the cases. The rate of stent thrombosis was 2.1%. There were no new episodes of stent thrombosis after the fifth year of follow-up. Comparative subanalysis showed no outcome differences between the different types of stents used, including Cypher®, Taxus®, and Endeavor®. These findings indicate that drug-eluting stents remain safe and effective at very long-term follow-up. Patients in the 'real world' may benefit from drug-eluting stenting with excellent, long-term results.

  13. Encapsulated human hepatocellular carcinoma cells by alginate gel beads as an in vitro metastasis model

    International Nuclear Information System (INIS)

    Xu, Xiao-xi; Liu, Chang; Liu, Yang; Li, Nan; Guo, Xin; Wang, Shu-jun; Sun, Guang-wei; Wang, Wei; Ma, Xiao-jun

    2013-01-01

    Hepatocellular carcinoma (HCC) is the most common primary liver cancer and often forms metastases, which are the most important prognostic factors. For further elucidation of the mechanism underlying the progression and metastasis of HCC, a culture system mimicking the in vivo tumor microenvironment is needed. In this study, we investigated the metastatic ability of HCC cells cultured within alginate gel (ALG) beads. In the culture system, HCC cells formed spheroids by proliferation and maintained in nuclear abnormalities. The gene and protein expression of metastasis-related molecules was increased in ALG beads, compared with the traditional adhesion culture. Furthermore, several gene expression levels in ALG bead culture system were even closer to liver cancer tissues. More importantly, in vitro invasion assay showed that the invasion cells derived from ALG beads was 7.8-fold higher than adhesion cells. Our results indicated that the in vitro three-dimensional (3D) model based on ALG beads increased metastatic ability compared with adhesion culture, even partly mimicked the in vivo tumor tissues. Moreover, due to the controllable preparation conditions, steady characteristics and production at large-scale, the 3D ALG bead model would become an important tool used in the high-throughput screening of anti-metastasis drugs and the metastatic mechanism research. -- Highlights: •We established a 3D metastasis model mimicking the metastatic ability in vivo. •The invasion ability of cells derived from our model was increased significantly. •The model is easy to reproduce, convenient to handle, and amenable for large-scale

  14. Current manufacturing processes of drug-eluting sutures.

    Science.gov (United States)

    Champeau, Mathilde; Thomassin, Jean-Michel; Tassaing, Thierry; Jérôme, Christine

    2017-11-01

    Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Two general approaches can be followed: (i) the ones that add the API into the material during the manufacturing process of the suture and (ii) the ones that load the API to an already manufactured suture. Areas covered: This review provides an overview of the current manufacturing processes for drug-eluting suture production and discusses their benefits and drawbacks depending on the type of drugs. The mechanical properties and the drug delivery profile of drug-eluting sutures are highlighted since these implants must fulfill both criteria. Expert opinion: For limited drug contents, melt extrusion and electrospinning are the emerging processes since the drug is added during the suture manufacture process. Advantageously, the drug release profile can be tuned by controlling the processing parameters specific to each process and the composition of the drug-containing polymer. If high drug content is targeted, the coating or grafting of a drug layer on a pre-manufactured suture allows for preservation of the tensile strength requirements of the suture.

  15. Development of a pheromone elution rate physical model

    Science.gov (United States)

    M.E. Teske; H.W. Thistle; B.L. Strom; H. Zhu

    2015-01-01

    A first principle modeling approach has been applied to available data describing the elution of semiochemicals from pheromone dispensers. These data included field data for 27 products developed by several manufacturers, including homemade devices, as well as environmental chamber data collected on three semiochemical products. The goal of this effort was to...

  16. Clinical benefits of drug-eluting stent implantation in septuagenarians with coronary artery disease

    International Nuclear Information System (INIS)

    Fang Yuehua; Shen Weifeng; Zhang Ruiyan; Zhang Jiansheng; Hu Jian; Zhang Xian; Zheng Aifang

    2005-01-01

    Objective: This study evaluated the safety and long-term outcomes of drug-eluting stents in septuagenarians with coronary artery disease. Methods: Two hundred and thirty-nine consecutive patients with coronary artery disease underwent drug-eluting stenting, including 88 patients aged ≥70 years (group A) and 151 aged <70 years (group B). Baseline clinical characteristics, procedural success rate, occurrence of cardiac events during follow-up were recorded and compared between the two groups. Results: Procedural success rate and complications were similar for the two groups. During follow-up, group A had higher recurrence rate of chest pain than group B (23.9% vs. 7.3%, P<0.001), and occurrence of cardiac events was higher in group A than in group B (5.7% vs. 2.7%, P<0.296). There was no significant difference in the frequency of restenosis between the two groups. Conclusions: Drug-eluting stent implantation for septuagenarians with coronary artery disease is safe but may have more recurrence of angina than younger ones during long-term follow-up. (authors)

  17. The elution of certain protein affinity tags with millimolar concentrations of diclofenac.

    Science.gov (United States)

    Baliova, Martina; Juhasova, Anna; Jursky, Frantisek

    2015-12-01

    Diclofenac (2-[(2, 6-dichlorophenyl)amino] benzeneacetic acid) is a sparingly soluble, nonsteroidal anti-inflammatory drug therapeutically acting at low micromolar concentrations. In pH range from 8 to 11, its aqueous solubility can be increased up to 200 times by the presence of counter ions such as sodium. Our protein interaction studies revealed that a millimolar concentration of sodium diclofenac is able to elute glutathione S-transferase (GST), cellulose binding protein (CBD), and maltose binding protein (MBP) but not histidine-tagged or PDZ-tagged proteins from their affinity resins. The elution efficiency of diclofenac is comparable with the eluting agents normally used at similar concentrations. Native gel electrophoresis of sodium diclofenac-treated proteins showed that the interaction is non-covalent and non-denaturing. These results suggest that sodium diclofenac, in addition to its pharmaceutical applications, can also be exploited as a lead for the development of new proteomics reagents. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Elution of Uranium and Calculation of Plate Number on the Column of Silica-TBP

    International Nuclear Information System (INIS)

    Endang Susiantini; Indra Suryawan

    2007-01-01

    Separation process of 99 Mo resulted of irradiated uranyl nitrate with an accelerator as the neutron source by the chromatographic extraction using column containing kiesel gel-TBP will be developed. Kiesel gel (silica) was used as an inert subpart, TBP as a phase stationary and simulated used natural uranyl nitrate of 200-300 g/l with the acidity of 2 N as the mobile phase. The inert support was made by means of kiesel-gel (silica) hydrophobization to change hydrophilic silica to hydrophobic silica, so that it could be impregnated by TBP. Uranium which has been attached to TBP would be eluted by dilute acid at acidity of 0.05; 0.1; 0.2 N HNO 3 ; Warm DW and cool DW. By using 0.1 N HNO 3 eluent and warm DW the uranium attached to silica-TBP could be eluted perfectly and more quickly than the three others eluent. Uranium concentration which were absorbed and eluted were analysed titrimetrically by using titan method and it was used to calculate Plate Number (N). The value of N obtained for the column which the inert support of 8 cm in height, 1 cm in diameter, 10 drops per minute by using of 0.1 N HNO 3 eluent was 300.6. (author)

  19. Chromium (VI) ion adsorption by grafted cross-linked chitosan beads in aqueous solution - a mathematical and statistical modeling study.

    Science.gov (United States)

    Igberase, E; Osifo, P; Ofomaja, A

    2017-12-01

    Chitosan outstanding qualities and efficient way of binding metal ions even to near zero concentration is the major reason for special attention. Modification of chitosan allows the polymer to be applied in numerous field of research. Depending on the modification techniques, chitosan possesses increased adsorption capacity. In this study chitosan beads (CS) were formulated from chitosan flakes, the beads were cross-linked with glutaraldehyde and thereafter grafted with ethyldiaminetetraacetic acid. The stability and amine concentration of the beads were determined. The chemical functionalities of the beads were obtained by Fourier transform infrared spectroscopy, X-ray diffraction and thermogravimetric analysis (TGA). However, in the adsorption studies with Cr(VI), the number of runs in the experiment was obtained by response surface methodology (RSM), and the maximum adsorption capacity (Q m ) from each run was determined from the Langmuir model. The results of the experiment showed that the non-modified beads were soluble at pH 1-4 and insoluble at pH 5, while the modified beads were insoluble at pH 1-6. The amine concentration of CS, CCS and grafted cross-linked chitosan beads (GCCS) were 4.4, 3.8 and 5.0 mmol/g, respectively. The point of zero charge (pH PZC ) of GCCS was found to be 4.4. The quadratic model was significant and adequate in describing the experimental data. The difference between experimental and predicted Q m was negligible. From the design matrix and results, increased Q m was achieved at pH 5, contact time 70 min, temperature 45°C, adsorbent dosage 5 g and initial concentration 70 mg/l. The desorption of the beads loaded with Cr(VI) was successful with 0.5 M HCl eluant and contact time of 180 min, leading to cost minimization.

  20. TiO2 beads and TiO2-chitosan beads for urease immobilization

    International Nuclear Information System (INIS)

    Ispirli Doğaç, Yasemin; Deveci, İlyas; Teke, Mustafa; Mercimek, Bedrettin

    2014-01-01

    The aim of the present study is to synthesize TiO 2 beads for urease immobilization. Two different strategies were used to immobilize the urease on TiO 2 beads. In the first method (A), urease enzyme was immobilized onto TiO 2 beads by adsorption and then crosslinking. In the second method (B), TiO 2 beads were coated with chitosan-urease mixture. To determine optimum conditions of immobilization, different parameters were investigated. The parameters of optimization were initial enzyme concentration (0.5; 1; 1.5; 2 mg/ml), alginate concentration (1; 2; 3%), glutaraldehyde concentration (1; 2; 3% v/v) and chitosan concentration (2; 3; 4 mg/ml). The optimum enzyme concentrations were determined as 1.5 mg/ml for A and 1.0 mg/ml for B. The other optimum conditions were found 2.0% (w/v) for alginate concentration (both A and B); 3.0 mg/ml for chitosan concentration (B) and 2.0% (v/v) for glutaraldehyde concentration (A). The optimum temperature (20-60 °C), optimum pH (3.0-10.0), kinetic parameters, thermal stability (4–70 °C), pH stability (4.0-9.0), operational stability (0-230 min) and reusability (20 times) were investigated for characterization. The optimum temperatures were 30 °C (A), 40 °C (B) and 35 °C (soluble). The temperature profiles of the immobilized ureases were spread over a large area. The optimum pH values for the soluble urease and immobilized urease prepared by using methods (A) and (B) were found to be 7.5, 7.0, 7.0, respectively. The thermal stabilities of immobilized enzyme sets were studied and they maintained 50% activity at 65 °C. However, at this temperature free urease protected only 15% activity. - Highlights: • TiO 2 and TiO 2 -chitosan beads for urease immobilization have been prepared and characterized. • The beads used in this work are good matrices for the immobilization of urease. • The immobilized urease was shown to have good properties and stabilities (pH and thermal stability, operational stability). • The 50

  1. Bead Collage: An Arts-Based Research Method

    Science.gov (United States)

    Kay, Lisa

    2013-01-01

    In this paper, "bead collage," an arts-based research method that invites participants to reflect, communicate and construct their experience through the manipulation of beads and found objects is explained. Emphasizing the significance of one's personal biography and experiences as a researcher, I discuss how my background as an…

  2. Growth and morphology of thermophilic dairy starters in alginate beads.

    Science.gov (United States)

    Lamboley, Laurence; St-Gelais, Daniel; Champagne, Claude P; Lamoureux, Maryse

    2003-06-01

    The aim of this research was to produce concentrated biomasses of thermophilic lactic starters using immobilized cell technology (ICT). Fermentations were carried out in milk using pH control with cells microentrapped in alginate beads. In the ICT fermentations, beads represented 17% of the weight. Some assays were carried out with free cells without pH control, in order to compare the ICT populations with those of classical starters. With Streptococcus thermophilus, overall populations in the fermentor were similar, but maximum bead population for (8.2 x 10(9) cfu/g beads) was 13 times higher than that obtained in a traditional starter (4.9 x 10(8) cfu/ml). For both Lactobacillus helveticus strains studied, immobilized-cell populations were about 3 x 10(9) cfu/g beads. Production of immobilized Lb. bulgaricus 210R strain was not possible, since no increases in viable counts occurred in beads. Therefore, production of concentrated cell suspension in alginate beads was more effective for S. thermophilus. Photomicrographs of cells in alginate beads demonstrated that, while the morphology of S. thermophilus remained unchanged during the ICT fermentation, immobilized cells of Lb. helveticus appeared wider. In addition, cells of Lb. bulgaricus were curved and elongated. These morphological changes would also impair the growth of immobilized lactobacilli.

  3. Towards a programmable magnetic bead microarray in a microfluidic channel

    DEFF Research Database (Denmark)

    Smistrup, Kristian; Bruus, Henrik; Hansen, Mikkel Fougt

    2007-01-01

    to use larger currents and obtain forces of longer range than from thin current lines at a given power limit. Guiding of magnetic beads in the hybrid magnetic separator and the construction of a programmable microarray of magnetic beads in the microfluidic channel by hydrodynamic focusing is presented....

  4. Concepts for increasing gentamicin release from handmade bone cement beads

    NARCIS (Netherlands)

    Rasyid, Hermawan N; van der Mei, Henny C; Frijlink, Henderik W; Soegijoko, Soegijardjo; Van Horn, Jim R; Busscher, Hendrik; Neut, Daniëlle

    2009-01-01

    BACKGROUND AND PURPOSE: Commercial gentamicin-loaded bone cement beads (Septopal) constitute an effective delivery system for local antibiotic therapy. These beads are not available in all parts of the world, and are too expensive for frequent use in others. Thus, orthopedic surgeons worldwide make

  5. Beaded Fiber Mats of PVA Containing Unsaturated Heteropoly Salt

    Institute of Scientific and Technical Information of China (English)

    Guo Cheng YANG; Yan PAN; Jian GONG; Chang Lu SHAO; Shang Bin WEN; Chen SHAO; Lun Yu QU

    2004-01-01

    Poly(vinyl alcohol) (PVA) fiber mats containing unsaturated heteropoly salt was prepared for the first time. IR, X-ray diffraction and SEM photographs characterized the beaded fiber mats.The viscoelasticity and the conductivity of the solution were the key factors that influence the formation of the beaded fiber mats.

  6. Optimization of weld bead geometry of MS plate

    Indian Academy of Sciences (India)

    The considered specimen was checked to harmonize the optimum setting between input factors, for example, welding current, open circuit voltage, and thickness of plate, with respect to obtaining prosperous weld strength as well as bead geometry quality characteristics, for example, tensile strength, bead width, ...

  7. SparseBeads data: benchmarking sparsity-regularized computed tomography

    DEFF Research Database (Denmark)

    Jørgensen, Jakob Sauer; Coban, Sophia B.; Lionheart, William R. B.

    2017-01-01

    -regularized reconstruction. A collection of 48 x-ray CT datasets called SparseBeads was designed for benchmarking SR reconstruction algorithms. Beadpacks comprising glass beads of five different sizes as well as mixtures were scanned in a micro-CT scanner to provide structured datasets with variable image sparsity levels...

  8. Analysis of U and Pu resin bead samples with a single stage mass spectrometer

    International Nuclear Information System (INIS)

    Smith, D.H.; Walker, R.L.; Bertram, L.K.; Carter, J.A.

    1979-01-01

    Resin bead sampling enables the shipment of nanogram U and Pu quantities for analysis. Application of this sampling technique to safeguards was investigated with a single-stage mass spectrometer. Standards gave results in good agreement with NBS certified values. External precisions of +-0.5% were obtained on isotopic ratios of approx. 0.01; precisions on quantitative measurements are +-1.0%

  9. In Vivo and In Vitro Elution of Analgesics from Multilayered Poly(D,L-lactide-co-glycolide Nanofibers Incorporated Ureteral Stents

    Directory of Open Access Journals (Sweden)

    Yi-Chia Lin

    2018-01-01

    Full Text Available We develop novel analgesic-eluting nanofiber-incorporated ureteral stents that offer sustained release of lidocaine and ketorolac for local drug delivery. Lidocaine and poly(D,L-lactide-co-glycolide (PLGA were dissolved in hexafluoroisopropanol and were electrospun into nonwoven nanofibers onto the surface of ureteral stents. This was followed by electrospinning of another layer of PLGA nanofibers containing ketorolac. Electrospun drug-loaded nanofibers were then characterized using scanning electron microscopy, Fourier transform infrared spectroscopy, and water contact angle analysis. In addition, the elution behavior characteristics of the analgesics, both in vivo and in vitro, from the nanofiber-incorporated stents were evaluated. Experimental results indicate that the analgesic-eluting ureteral stents could liberate high strengths of analgesics in vitro and in vivo for at least 50 and 30 days, respectively. The analgesic-eluting nanofiber-incorporated ureteral stents are potentially applicable for alleviating the discomfort associated with stent implant.

  10. l-Arginine grafted alginate hydrogel beads: A novel pH-sensitive system for specific protein delivery

    Directory of Open Access Journals (Sweden)

    Mohamed S. Mohy Eldin

    2015-05-01

    Full Text Available Novel pH-sensitive hydrogels based on l-arginine grafted alginate (Arg-g-Alg hydrogel beads were synthesized and utilized as a new carrier for protein delivery (BSA in specific pH media. l-arginine was grafted onto the polysaccharide backbone of virgin alginate via amine functions. Evidences of grafting of alginate were extracted from FT-IR and thermal analysis, while the morphological structure of Arg-g-Alg hydrogel beads was investigated by SEM photographs. Factors affecting on the grafting process e.g. l-arginine concentration, reaction time, reaction temperature, reaction pH, and crosslinking conditions, have been studied. Whereas, grafting efficiency of each factor was evaluated. Grafting of alginate has improved both thermal and morphological properties of Arg-g-Alg hydrogel beads. The swelling behavior of Arg-g-Alg beads was determined as a function of pH and compared with virgin calcium alginate beads. The cumulative in vitro release profiles of BSA loaded beads were studied at different pHs for simulating the physiological environments of the gastrointestinal tract. The amount of BSA released from neat alginate beads at pH 2 was almost 15% after 5 h, while the Arg-g-Alg beads at the same conditions were clearly higher than 45%, then it increased to 90% at pH 7.2. Accordingly, grafting of alginate has improved its release profile behavior particularly in acidic media. The preliminary results clearly suggested that the Arg-g-Alg hydrogel may be a potential candidate for polymeric carrier for oral delivery of protein or drugs.

  11. Development and in vivo evaluation of chitosan beads for the colonic delivery of azathioprine for treatment of inflammatory bowel disease.

    Science.gov (United States)

    Helmy, Abdelrahman M; Elsabahy, Mahmoud; Soliman, Ghareb M; Mahmoud, Mahmoud A; Ibrahim, Elsayed A

    2017-11-15

    Azathioprine is a highly efficient immunosuppressant drug used for treatment of inflammatory bowel disease (IBD). Systemic administration of azathioprine results in delayed therapeutic effect and serious adverse reactions. In the current study, we have developed, for the first time, colon-targeted chitosan beads for delivery of azathioprine in colitis rabbit model. Several characterizations were performed for the azathioprine-loaded beads (e.g. drug encapsulation efficiency, drug loading capacity, yield, size, shape and compatibility with other ingredients). The in vitro release profiles of acid-resistant capsules filled with azathioprine-loaded beads showed that most of azathioprine was released in IBD colon simulating medium. The therapeutic effects of azathioprine-loaded beads and azathioprine crude drug were examined on acetic acid-induced colitis rabbit model. Improved therapeutic outcomes were observed in the animals treated with the azathioprine-loaded beads, as compared to the untreated animal controls and the animals treated with the azathioprine free drug, based on the clinical activity score, index of tissue edema, mortality rate, colon macroscopic score and colon histopathological features. In the animals treated with the azathioprine-loaded beads, the levels of the inflammatory mediators, myeloperoxidase enzyme and tumor necrosis factor-α, were significantly reduced to levels similar to those observed in the normal rabbits. Furthermore, the activities of the antioxidant enzymes, superoxide dismutase and catalase, were restored considerably in the animals treated with the drug-loaded beads. The azathioprine-loaded beads developed in the current study might have great potential in the management of IBD. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. THE BEHAVIOR OF SOLUBLE METALS ELUTED FROM Ni/Fe-BASED ALLOY REACTORS AFTER HIGH-TEMPERATURE AND HIGH-PRESSURE WATER PROCESS

    Directory of Open Access Journals (Sweden)

    M. Faisal

    2012-05-01

    Full Text Available The behavior of heavy metals eluted from the wall of Ni/Fe-based alloy reactors after high-temperature and high-pressure water reaction were studied at temperatures ranging from 250 to 400oC. For this purpose, water and cysteic acid were heated in two reactor materials which are SUS 316 and Inconel 625. Under the tested conditions, the erratic behaviors of soluble metals eluted from the wall of Ni/Fe-based alloy in high temperature water were observed. Results showed that metals could be eluted even at a short contact time. The presence of air also promotes elution at sub-critical conditions. At sub-critical conditions, a significant amount of Cr was extracted from SUS 316, while only traces of Ni, Fe, Mo and Mn were eluted. In contrast, Ni was removed in significant amounts compared to Cr when Inconel 625 was tested. It was observed that eluted metals tend to increased under acidic conditions and most of those metals were over the limit of WHO guideline for drinking water. The results are significant both on the viewpoint of environmental regulation on disposal of wastes containing heavy metals, toxicity of resulting product and catalytic effect on a particular reaction.

  13. Entrapment of laurel lipase in chitosan hydrogel beads.

    Science.gov (United States)

    Yagar, Hulya; Balkan, Ugur

    2017-08-01

    Laurel seed lipase was entrapped within chitosan beads with ionotropic gelatin method using tripolyphosphate (TPP) as multivalent covalent counter ion. Immobilization yield was 78%. First, optimum immobilization conditions were determined, and morphology of chitosan beads was characterized by scanning electron microscopy. Optimum pH and temperature were evaluated as 6.0 and 40 °C, respectively. The immobilized beads saved about 55% of its activities at 60° while saved about 32% at 70 °C for 30 min. V max /K m values were determined as 31.75 and 2.87 using olive oil as substrate for immobilized beads and free enzyme, respectively. Immobilized beads showed the activities during 30 days at +4 °C.

  14. A NOVEL APPROACH TO SYNTHESIZE CHITOSAN BEADS CROSSLINKED BY EPICHLOROHYDRIN

    Institute of Scientific and Technical Information of China (English)

    WANG Yongjian; BAI Shu; SUN Yan

    2001-01-01

    The present investigation describes a novel method for preparing spherical chitosan particles based on crosslinking with epichlorohydrin. Certain amount of pre-crosslinking agent was added to form chitosan gels by traditional inverse phase suspension polymerization. Then the gels were crosslinked by epichlorohydrin at basic condition to obtain chitosan beads. The effects of reaction conditions, such as crosslinking time, the amount of crosslinking agent and the NaOtt concentration,on the physical properties of the chitosan beads were investigated. The beads were found to have more amino groups in the polymer chains than the beads crosslinked by glutaraldehyde. The capacity for copper ions is as high as 40mg/g. The beads have good mechanical strength and can be reused.

  15. A NOVEL APPROACH TO SYNTHESIZE CHITOSAN BEADS CROSSLINKED BY EPICHLOROHYDRIN

    Institute of Scientific and Technical Information of China (English)

    WANGYongjina; BAIShu; 等

    2001-01-01

    The present investigation describes a novel method for preparing spherical chitosan particles based on crosslinking with epichlorohydrin.Certain amount of pre-crosslinking agent was added to form chitosan gels by traditional inverse phase suspension polymerization.Then the gels were crosslinked by epichlorohydrin at basic condition to obtain chitosan beads.The effects of reaction conditions,such as crosslinking time,the amount of crosslinking agent and the NaOH concentration,on the physical properties of the chitosan beads were investigated.The beads were found to have more amino groups in the polymer chains than the beads crosslinked by glutaraldehyde.The capacity for copper ions in as high as 40mg/g,The beads have good mechanical strength and can be reused.

  16. Bead magnetorelaxometry with an on-chip magnetoresistive sensor

    DEFF Research Database (Denmark)

    Dalslet, Bjarke Thomas; Damsgaard, Christian Danvad; Donolato, Marco

    2011-01-01

    Magnetorelaxometry measurements on suspensions of magnetic beads are demonstrated using a planar Hall effect sensor chip embedded in a microfluidic system. The alternating magnetic field used for magnetizing the beads is provided by the sensor bias current and the complex magnetic susceptibility...... spectra are recorded as the 2nd harmonic of the sensor response. The complex magnetic susceptibility signal appears when a magnetic bead suspension is injected, it scales with the bead concentration, and it follows the Cole-Cole expression for Brownian relaxation. The complex magnetic susceptibility...... signal resembles that from conventional magnetorelaxometry done on the same samples apart from an offset in Brownian relaxation frequency. The time dependence of the signal can be rationalized as originating from sedimented beads....

  17. Adsorption and recovery of lead(II) from aqueous solutions by immobilized Pseudomonas Aeruginosa PU21 beads

    International Nuclear Information System (INIS)

    Lin, C.-C.; Lai, Y.-T.

    2006-01-01

    In this study, immobilized Pseudomonas aeruginosa PU21 beads were used as an adsorbent for lead(II). Different weight percentages of chitosan were added to polyethylene glycol (PEG, 0.5 wt.% in aqueous solution) and alginate (18 wt.% in aqueous solution), and then blended or cross-linked using different concentrations of epichlorohydrin (ECH) to prepare beads of different sizes and increased mechanical strength. Before blending or cross-linking, different weight percentages of P. aeruginosa PU21 were added to increase lead(II) adsorption. Subsequently the optimized bead composition (concentration of ECH, percentages of chitosan and P. aeruginosa PU21) and the optimum adsorption conditions (agitation rate and pH in the aqueous solution) were ascertained. Finally, the optimized beads adsorbing lead(II) were regenerated by 0.1 M aqueous HCl solutions and the most effective desorption agitation rate was ascertained. The results indicate that the reuse of immobilized P. aeruginosa PU21 beads was feasible. In addition, the equilibrium adsorption, kinetics, changes in the thermodynamic properties of adsorption of lead(II) on optimized beads were also investigated

  18. A half-ring GMR sensor for detection of magnetic beads immobilized on a circular micro-trap

    KAUST Repository

    Gooneratne, Chinthaka Pasan

    2011-11-01

    Utilizing magnetic principles in biological immunoassays is an attractive option given its ability to remotely and non-invasively manipulate and detect cells tagged with micro/nano size superparamagnetic type beads and due to the fact that even the most complex biological immunoassays will have very little magnetic effect. The presence of magnetic beads can be detected by a magnetic sensor which quantifies the amount of target cells present in the immunoassay. In order to increase the detection rate a circular conducting micro-trap is employed to attract, trap and transport the magnetic beads to the sensing area. In this research we propose a half-ring spin valve type giant magnetoresistance (GMR) sensor for the measurement of stray fields produced by 2 μm magnetic beads which are around the circular micro-trap. A couple of half-ring GMR sensors can be used to cover the entire circular border width, in order to detect the majority of the immobilized magnetic beads. Analytical and numerical analysis leading towards the fabrication of the half-ring GMR sensor are presented. DC characterization of the fabricated sensor showed a magnetoresistance of 5.9 %. Experimental results showed that the half-ring GMR sensor detected the presence of 2 μm magnetic beads. Hence, half-ring GMR sensors integrated with a circular micro-trap have great potential to be used as an effective disease diagnostic device. © 2011 IEEE.

  19. Alginate-caseinate composites: Molecular interactions and characterization of cross-linked beads for the delivery of anticandidals.

    Science.gov (United States)

    Khlibsuwan, Rapee; Khunkitti, Watcharee; Pongjanyakul, Thaned

    2018-04-19

    Polysaccharide-protein composites offer potential utility for the delivery of drugs. The objectives of this work were to investigate the molecular interactions between sodium alginate (SA) and sodium caseinate (SC) in dispersions and films and to characterize calcium alginate (CA) beads mixed with SC for the delivery of fluconazole (FZ) and clotrimazole (CZ). The results demonstrated that SA could interact with SC, which caused a viscosity synergism in the dispersions. Hydrogen bonding between the carboxyl or hydroxyl groups of SA and the amide groups of SC led to the formation of soluble complexes that could reinforce the CA beads prepared by calcium cross-linking. The SC-CA beads provided higher drug entrapment efficiency, lower water uptake and erosion, and slower drug release than for the CA beads. The loaded FZ was an amorphous form, but CZ crystals were embedded in the bead matrix due to the low water solubility of this drug. However, SC micellization could enhance the water solubility and efficacy of CZ against Candida albicans. This finding indicates that SA can interact with SC via hydrogen bonding to form complexes and that the anticandidal-loaded SC-CA beads can be used as drug delivery systems and drug reservoirs in tablets for oral candidiasis. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Zanamivir immobilized magnetic beads for voltammetric measurement of neuraminidase at gold-modified boron doped diamond electrode

    Energy Technology Data Exchange (ETDEWEB)

    Wahyuni, Wulan Tri, E-mail: wulantriws@gmail.com [Department of Chemistry, Faculty of Mathematics and Natural Sciences, Bogor Agricultural University, Kampus IPB Darmaga, Bogor 16680 (Indonesia); Department of Chemistry, FMIPA, Universitas Indonesia, Kampus UI Depok (Indonesia); Ivandini, Tribidasari A.; Saepudin, Endang [Department of Chemistry, FMIPA, Universitas Indonesia, Kampus UI Depok (Indonesia); Einaga, Yasuaki [Department of Chemistry, Faculty of Science and Technology, Keio University, Hiyoshi 3-14-1, Yokohama 223-8522 (Japan); CREST, JST, 3-14-1 Hiyoshi, Yokohama 223-8522 (Japan)

    2016-04-19

    Biomolecule modified magnetic beads has been widely used in separation and sensing process. This study used streptavidin modified magnetic beads to immobilize biotin modified zanamivir. Biotin-streptavidin affinity facilitates immobilization of zanamivir on magnetic beads. Then interaction of zanamivir and neuraminidase was adopted as basic for enzyme detection. Detection of neuraminidase was performed at gold modified BDD using cyclic voltammetry technique. The measurement was carried out based on alteration of electrochemical signals of working electrode as neuraminidase response. The result showed that zanamivir was successfully immobilized on magnetic beads. The optimum amount of magnetic beads for zanamivir immobilization was 120 ug. Linear responses of neuraminidase were detected in concentration range of 0-15 mU. Detection limit (LOD) of measurement was 2.32 mU (R2 = 0.959) with precision as % RSD of 1.41%. Measurement of neuraminidase on magnetic beads could be also performed in the presence of mucin matrix. The linearity range was 0-8 mU with LOD of 0.64 mU (R2 = 0.950) and % RSD of 7.25%.

  1. A half-ring GMR sensor for detection of magnetic beads immobilized on a circular micro-trap

    KAUST Repository

    Gooneratne, Chinthaka Pasan; Liang, Cai; Useinov, Arthur; Kosel, Jü rgen; Giouroudi, Ioanna

    2011-01-01

    Utilizing magnetic principles in biological immunoassays is an attractive option given its ability to remotely and non-invasively manipulate and detect cells tagged with micro/nano size superparamagnetic type beads and due to the fact that even the most complex biological immunoassays will have very little magnetic effect. The presence of magnetic beads can be detected by a magnetic sensor which quantifies the amount of target cells present in the immunoassay. In order to increase the detection rate a circular conducting micro-trap is employed to attract, trap and transport the magnetic beads to the sensing area. In this research we propose a half-ring spin valve type giant magnetoresistance (GMR) sensor for the measurement of stray fields produced by 2 μm magnetic beads which are around the circular micro-trap. A couple of half-ring GMR sensors can be used to cover the entire circular border width, in order to detect the majority of the immobilized magnetic beads. Analytical and numerical analysis leading towards the fabrication of the half-ring GMR sensor are presented. DC characterization of the fabricated sensor showed a magnetoresistance of 5.9 %. Experimental results showed that the half-ring GMR sensor detected the presence of 2 μm magnetic beads. Hence, half-ring GMR sensors integrated with a circular micro-trap have great potential to be used as an effective disease diagnostic device. © 2011 IEEE.

  2. Process parameters-weld bead geometry interactions and their influence on mechanical properties: A case of dissimilar aluminium alloy electron beam welds

    Directory of Open Access Journals (Sweden)

    P. Mastanaiah

    2018-04-01

    Full Text Available Prediction of weld bead geometry is always an interesting and challenging research topic as it involves understanding of complex multi input and multi output system. The weld bead geometry has a profound impact on the load bearing capability of a weld joint, which in-turn decides the performance in real time service conditions. The present study introduces a novel approach of detecting a relationship between weld bead geometry and mechanical properties (e.g. tensile load for the purpose of catering the best the process could offer. The significance of the proposed approach is demonstrated by a case of dissimilar aluminium alloy (AA2219 and AA5083 electron beam welds. A mathematical model of tensile braking load as a function of geometrical attributes of weld bead geometry is presented. The results of investigation suggests the effective thickness of weld – a geometric parameter of weld bead has the most significant influence on tensile breaking load of dissimilar weld joint. The observations on bead geometry and the mechanical properties (microhardness, ultimate tensile load and face bend angle are correlated with detailed metallurgical analysis. The fusion zone of dissimilar electron beam weld has finer grain size with a moderate evaporation and segregation of alloying elements magnesium and copper respectively. The mechanical properties of weld joint are controlled by optimum bead geometry and HAZ softening in weaker AA5083 Al alloy. Keywords: Electron beam welding, AA2219, AA5083, Bead geometry, Tensile breaking load

  3. Sirolimus-eluting versus bare-metal stent implantation in patients with ostial lesions

    DEFF Research Database (Denmark)

    Jørgensen, Erik; Kelbæk, Henning; Kløvgaard, Lene

    2010-01-01

    To investigate the efficacy of implantation of sirolimus-eluting stents (SES) in the ostium of coronary arteries.......To investigate the efficacy of implantation of sirolimus-eluting stents (SES) in the ostium of coronary arteries....

  4. Biodegradable Polymer Biolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents in Patients With Coronary Artery Disease: Final 5-Year Report From the COMPARE II Trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent).

    Science.gov (United States)

    Vlachojannis, Georgios J; Smits, Pieter C; Hofma, Sjoerd H; Togni, Mario; Vázquez, Nicolás; Valdés, Mariano; Voudris, Vassilis; Slagboom, Ton; Goy, Jean-Jaques; den Heijer, Peter; van der Ent, Martin

    2017-06-26

    This analysis investigates the 5-year outcomes of the biodegradable polymer biolimus-eluting stent (BP-BES) and durable polymer everolimus-eluting stent (DP-EES) in an all-comers population undergoing percutaneous coronary intervention. Recent 1- and 3-year results from randomized trials have indicated similar safety and efficacy outcomes of BP-BES and DP-EES. Whether benefits of the biodegradable polymer device arise over longer follow-up is unknown. Moreover, in-depth, prospective, long-term follow-up data on metallic drug-eluting stents with durable or biodegradable polymers are scarce. The COMPARE II trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent) was a prospective, randomized, multicenter, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BP-BES or DP-EES. The pre-specified endpoint at 5 years was major adverse cardiac events, a composite of cardiac death, nonfatal myocardial infarction, or target vessel revascularization. Five-year follow-up was available in 2,657 patients (98%). At 5 years, major adverse cardiac events occurred in 310 patients (17.3%) in the BP-BES group and 142 patients (15.6%) in the DP-EES group (p = 0.26). The rate of the combined safety endpoint all-cause death or myocardial infarction was 15.0% in the BP-BES group versus 14.8% in the DP-EES group (p = 0.90), whereas the efficacy measure target vessel revascularization was 10.6% versus 9.0% (p = 0.18), respectively. Interestingly, definite stent thrombosis rates did not differ between groups (1.5% for BP-BES vs. 0.9% for DP-EES; p = 0.17). The 5-year analysis comparing biodegradable polymer-coated BES and the durable polymer-coated EES confirms the initial early- and mid-term results regarding similar safety and efficacy outcomes in this all-comers percutaneous coronary intervention population. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights

  5. Switchable cell trapping using superparamagnetic beads

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, M. T.; Smith, K. H.; Real, M. E.; Bashir, M. A.; Fry, P. W.; Fischer, P.; Im, M.-Y.; Schrefl, T.; Allwood, D. A.; Haycock, J. W.

    2010-04-30

    Ni{sub 81}Fe{sub 19} microwires are investigated as the basis of a switchable template for positioning magnetically-labeled neural Schwann cells. Magnetic transmission X-ray microscopy and micromagnetic modeling show that magnetic domain walls can be created or removed in zigzagged structures by an applied magnetic field. Schwann cells containing superparamagnetic beads are trapped by the field emanating from the domain walls. The design allows Schwann cells to be organized on a surface to form a connected network and then released from the surface if required. As aligned Schwann cells can guide nerve regeneration, this technique is of value for developing glial-neuronal co-culture models in the future treatment of peripheral nerve injuries.

  6. Metallic gold beads in hyaluronic acid

    DEFF Research Database (Denmark)

    Pedersen, Dan Sonne; Tran, Thao Phuong; Smidt, Kamille

    2013-01-01

    . In conclusion, our findings support that bio-liberation of gold from metallic gold surfaces have anti-inflammatory properties similar to classic gold compounds, warranting further studies into the pharmacological potential of this novel gold-treatment and the possible synergistic effects of hyaluronic acid....... by exploiting macrophage-induced liberation of gold ions (dissolucytosis) from gold surfaces. Injecting gold beads in hyaluronic acid (HA) as a vehicle into the cavities of the brain can delay clinical signs of disease progression in the MS model, experimental autoimmune encephalitis (EAE). This study...... investigates the anti-inflammatory properties of metallic gold/HA on the gene expression of tumor necrosis factor (Tnf-α), Interleukin (Il)-1β, Il-6, Il-10, Colony-stimulating factor (Csf)-v2, Metallothionein (Mt)-1/2, Bcl-2 associated X protein (Bax) and B cell lymphoma (Bcl)-2 in cultured J774 macrophages...

  7. On-chip signal amplification of magnetic bead-based immunoassay by aviating magnetic bead chains.

    Science.gov (United States)

    Jalal, Uddin M; Jin, Gyeong Jun; Eom, Kyu Shik; Kim, Min Ho; Shim, Joon S

    2017-11-06

    In this work, a Lab-on-a-Chip (LOC) platform is used to electromagnetically actuate magnetic bead chains for an enhanced immunoassay. Custom-made electromagnets generate a magnetic field to form, rotate, lift and lower the magnetic bead chains (MBCs). The cost-effective, disposable LOC platform was made with a polymer substrate and an on-chip electrochemical sensor patterned via the screen-printing process. The movement of the MBCs is controlled to improve the electrochemical signal up to 230% when detecting beta-type human chorionic gonadotropin (β-hCG). Thus, the proposed on-chip MBC-based immunoassay is applicable for rapid, qualitative electrochemical point-of-care (POC) analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Increased Growth of the Microalga Chlorella vulgaris when Coimmobilized and Cocultured in Alginate Beads with the Plant-Growth-Promoting Bacterium Azospirillum brasilense†

    Science.gov (United States)

    Gonzalez, Luz E.; Bashan, Yoav

    2000-01-01

    Coimmobilization of the freshwater microalga Chlorella vulgaris and the plant-growth-promoting bacterium Azospirillum brasilense in small alginate beads resulted in a significantly increased growth of the microalga. Dry and fresh weight, total number of cells, size of the microalgal clusters (colonies) within the bead, number of microalgal cells per cluster, and the levels of microalgal pigments significantly increased. Light microscopy revealed that both microorganisms colonized the same cavities inside the beads, though the microalgae tended to concentrate in the more aerated periphery while the bacteria colonized the entire bead. The effect of indole-3-acetic acid addition to microalgal culture prior to immobilization of microorganisms in alginate beads partially imitated the effect of A. brasilense. We propose that coimmobilization of microalgae and plant-growth-promoting bacteria is an effective means of increasing microalgal populations within confined environments. PMID:10742237

  9. Inhibitive Effect of antibiotic-loaded beads to cure chronic osteomyelitis in developing country : Hand-made vs commercial beads

    NARCIS (Netherlands)

    Rasyid, Hcrmawan N.; Van Horn, Jim R.; Van der Mei, Henny C.; Soegijoko, Sooegijardjo; Busscher, Henk J.; Neut, Danielle; Ibrahim, F; Osman, NAA; Usman, J; Kadri, NA

    2007-01-01

    Local antibiotic-loaded beads have been approved for standard treatment of orthopaedic pathogens, especially chronic osteomyelitis. Septopal (R), the only commercial local antibiotic bead available on the market, is expensive and contains only gentamicin. This study aimed to compare the in vitro

  10. A prospective, randomized evaluation of a novel everolimus-eluting coronary stent

    DEFF Research Database (Denmark)

    Stone, Gregg W; Teirstein, Paul S; Meredith, Ian T

    2011-01-01

    We sought to evaluate the clinical outcomes with a novel platinum chromium everolimus-eluting stent (PtCr-EES) compared with a predicate cobalt chromium everolimus-eluting stent (CoCr-EES) in patients undergoing percutaneous coronary intervention (PCI).......We sought to evaluate the clinical outcomes with a novel platinum chromium everolimus-eluting stent (PtCr-EES) compared with a predicate cobalt chromium everolimus-eluting stent (CoCr-EES) in patients undergoing percutaneous coronary intervention (PCI)....

  11. How capping protein enhances actin filament growth and nucleation on biomimetic beads.

    Science.gov (United States)

    Wang, Ruizhe; Carlsson, Anders E

    2015-11-25

    Capping protein (CP), which caps the growing ends of actin filaments, accelerates actin-based motility. Recent experiments on biomimetic beads have shown that CP also enhances the rate of actin filament nucleation. Proposed explanations for these phenomena include (i) the actin funneling hypothesis (AFH), in which the presence of CP increases the free-actin concentration, and (ii) the monomer gating model, in which CP binding to actin filament barbed ends makes more monomers available for filament nucleation. To establish how CP increases the rates of filament elongation and nucleation on biomimetic beads, we perform a quantitative modeling analysis of actin polymerization, using rate equations that include actin filament nucleation, polymerization and capping, as modified by monomer depletion near the surface of the bead. With one adjustable parameter, our simulation results match previously measured time courses of polymerized actin and filament number. The results support a version of the AFH where CP increases the local actin monomer concentration at the bead surface, but leaves the global free-actin concentration nearly constant. Because the rate of filament nucleation increases with the monomer concentration, the increased local monomer concentration enhances actin filament nucleation. We derive a closed-form formula for the characteristic CP concentration where the local free-actin concentration reaches half the bulk value, and find it to be comparable to the global Arp2/3 complex concentration. We also propose an experimental protocol for distinguishing branching nucleation of filaments from spontaneous nucleation.

  12. A flow cytometric assay technology based on quantum dots-encoded beads

    International Nuclear Information System (INIS)

    Wang Haiqiao; Liu Tiancai; Cao Yuancheng; Huang Zhenli; Wang Jianhao; Li Xiuqing; Zhao Yuandi

    2006-01-01

    A flow cytometric detecting technology based on quantum dots (QDs)-encoded beads has been described. Using this technology, several QDs-encoded beads with different code were identified effectively, and the target molecule (DNA sequence) in solution was also detected accurately by coupling to its complementary sequence probed on QDs-encoded beads through DNA hybridization assay. The resolution of this technology for encoded beads is resulted from two longer wavelength fluorescence identification signals (yellow and red fluorescent signals of QDs), and the third shorter wavelength fluorescence signal (green reporting signal of fluorescein isothiocyanate (FITC)) for the determination of reaction between probe and target. In experiment, because of QDs' unique optical character, only one excitation light source was needed to excite the QDs and probe dye FITC synchronously comparing with other flow cytometric assay technology. The results show that this technology has present excellent repeatability and good accuracy. It will become a promising multiple assay platform in various application fields after further improvement

  13. Piroxicam loaded alginate beads obtained by prilling/microwave tandem technique: morphology and drug release.

    Science.gov (United States)

    Aquino, Rita P; Auriemma, Giulia; d'Amore, Matteo; D'Ursi, Anna Maria; Mencherini, Teresa; Del Gaudio, Pasquale

    2012-07-01

    This paper presents a tandem technique, based on the combination of prilling and microwave (MW) assisted treatments, to produce biodegradable alginate carriers of piroxicam with different drug controlled release behaviours. Results showed that alginate/piroxicam beads demonstrated high encapsulation efficiency and very narrow dimensional distribution. Beads dried by MW retained shape and size distribution of the hydrated particles while drying rate was strongly increased compared to convective drying processes. Moreover, different MW irradiation regimes promoted interactions between the drug and alginate matrix, affected drug polymorphism as well as inner and surface matrix structure leading to different piroxicam release profiles. High level MW irradiation led to beads with highly porous and swellable matrix able to release piroxicam in few minutes in the intestine while convective drying produced gastro-resistant beads that exhibit sustained piroxicam release (total release in 5.5h) in intestinal environment. On these results the tandem technique prilling/MW irradiation appears to be promising to obtain alginate carrier with tailored NSAIDs release depending on drug characteristics and MW irradiation. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Determination of 99Mo contamination in 99mTc elute obtained from 99Mo/99mTc- generator

    International Nuclear Information System (INIS)

    Momennezhad, M.; Zakavi, S. R.; Sadeghi, R.

    2010-01-01

    99m Tc is a widely used radioisotope in nuclear medicine centers which is obtained by elution from Mo-99/Tc-99m generators. Usually the generators are either supplied by the Iran Atomic Energy Agency or by private companies from foreign countries. In this study we have measured 99 Mo contamination in 99m Tc elute from different generators in a period of one year. Materials and Methods: The radionuclide impurity of the 99m Tc elute were studied in two types of radionuclide generators (A: produced in Iran and B: Imported from other country). In-vitro measurements were performed using dose calibrator. Direct measurements were made, using a standard canister at the time of milking of the generators and also in Subsequent hours after milking. Results: The results showed a mean of 99 Mo impurity in generators A and B to be 0.00932±0.0043 and 0.0170±0.0127 respectively. Although the results showed that the 99 Mo contamination in 99 mTc elute was lesser than the maximum accepted activity limit of 0.015%, the difference in these two types may reflect different methods of productions of generator, as well as the quality control procedures. Conclusion: The mean of 99 Mo contamination in generators produced in Iran Atomic Energy Organization was lesser than generators imported from foreign origin.

  15. Energy efficient bead milling of microalgae: Effect of bead size on disintegration and release of proteins and carbohydrates.

    Science.gov (United States)

    Postma, P R; Suarez-Garcia, E; Safi, C; Yonathan, K; Olivieri, G; Barbosa, M J; Wijffels, R H; Eppink, M H M

    2017-01-01

    The disintegration of three industry relevant algae (Chlorella vulgaris, Neochloris oleoabundans and Tetraselmis suecica) was studied in a lab scale bead mill at different bead sizes (0.3-1mm). Cell disintegration, proteins and carbohydrates released into the water phase followed a first order kinetics. The process is selective towards proteins over carbohydrates during early stages of milling. In general, smaller beads led to higher kinetic rates, with a minimum specific energy consumption of ⩽0.47kWhkg DW -1 for 0.3mm beads. After analysis of the stress parameters (stress number and stress intensity), it appears that optimal disintegration and energy usage for all strains occurs in the 0.3-0.4mm range. During the course of bead milling, the native structure of the marker protein Rubisco was retained, confirming the mildness of the disruption process. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. A dynamic bead-based microarray for parallel DNA detection

    International Nuclear Information System (INIS)

    Sochol, R D; Lin, L; Casavant, B P; Dueck, M E; Lee, L P

    2011-01-01

    A microfluidic system has been designed and constructed by means of micromachining processes to integrate both microfluidic mixing of mobile microbeads and hydrodynamic microbead arraying capabilities on a single chip to simultaneously detect multiple bio-molecules. The prototype system has four parallel reaction chambers, which include microchannels of 18 × 50 µm 2 cross-sectional area and a microfluidic mixing section of 22 cm length. Parallel detection of multiple DNA oligonucleotide sequences was achieved via molecular beacon probes immobilized on polystyrene microbeads of 16 µm diameter. Experimental results show quantitative detection of three distinct DNA oligonucleotide sequences from the Hepatitis C viral (HCV) genome with single base-pair mismatch specificity. Our dynamic bead-based microarray offers an effective microfluidic platform to increase parallelization of reactions and improve microbead handling for various biological applications, including bio-molecule detection, medical diagnostics and drug screening

  17. From drug eluting stents to bioresorbable scaffolds; to new horizons in PCI

    NARCIS (Netherlands)

    Tenekecioglu, Erhan; Bourantas, Christos; Abdelghani, Mohammad; Zeng, Yaping; Silva, Rafael Cavalcante; Tateishi, Hiroki; Sotomi, Yohei; Onuma, Yoshinobu; Yılmaz, Mustafa; Serruys, Patrick W.

    2016-01-01

    Drug eluting stents and particularly the fully bioresorbable drug-eluting scaffolds herald a new era in percutaneous treatment of coronary artery disease. There has been tremendous progress in drug eluting stents with fully biodegradable coating polymers and polymer-free devices with reservoir

  18. Comparison of Durable-Polymer Zotarolimus-Eluting and Biodegradable-Polymer Biolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease

    DEFF Research Database (Denmark)

    Raungaard, Bent; Christiansen, Evald H; Bøtker, Hans Erik

    2017-01-01

    artery disease or acute coronary syndromes and at least 1 coronary artery lesion requiring treatment with a drug-eluting stent. Endpoints included major adverse cardiac events (MACE), a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion......OBJECTIVES: The authors sought to compare the safety and efficacy of the biocompatible durable-polymer zotarolimus-eluting stent with the biodegradable-polymer biolimus-eluting stent in unselected coronary patients. BACKGROUND: Biodegradable-polymer biolimus-eluting stents are superior to first......-generation durable-polymer drug-eluting stents in long-term randomized all-comer trials. Long-term data comparing them to second-generation durable-polymer drug-eluting stents are lacking. METHODS: The study was a randomized, multicenter, all-comer, noninferiority trial in patients with chronic stable coronary...

  19. DWPF GLASS BEADS AND GLASS FRIT TRANSPORT DEMONSTRATION

    Energy Technology Data Exchange (ETDEWEB)

    Adamson, D; Bradley Pickenheim, B

    2008-11-24

    DWPF is considering replacing irregularly shaped glass frit with spherical glass beads in the Slurry Mix Evaporator (SME) process to decrease the yield stress of the melter feed (a non-Newtonian Bingham Plastic). Pilot-scale testing was conducted on spherical glass beads and glass frit to determine how well the glass beads would transfer when compared to the glass frit. Process Engineering Development designed and constructed the test apparatus to aid in the understanding and impacts that spherical glass beads may have on the existing DWPF Frit Transfer System. Testing was conducted to determine if the lines would plug with the glass beads and the glass frit slurry and what is required to unplug the lines. The flow loop consisted of vertical and horizontal runs of clear PVC piping, similar in geometry to the existing system. Two different batches of glass slurry were tested: a batch of 50 wt% spherical glass beads and a batch of 50 wt% glass frit in process water. No chemicals such as formic acid was used in slurry, only water and glass formers. The glass beads used for this testing were commercially available borosilicate glass of mesh size -100+200. The glass frit was Frit 418 obtained from DWPF and is nominally -45+200 mesh. The spherical glass beads did not have a negative impact on the frit transfer system. The transferring of the spherical glass beads was much easier than the glass frit. It was difficult to create a plug with glass bead slurry in the pilot transfer system. When a small plug occurred from setting overnight with the spherical glass beads, the plug was easy to displace using only the pump. In the case of creating a man made plug in a vertical line, by filling the line with spherical glass beads and allowing the slurry to settle for days, the plug was easy to remove by using flush water. The glass frit proved to be much more difficult to transfer when compared to the spherical glass beads. The glass frit impacted the transfer system to the point

  20. DWPF GLASS BEADS AND GLASS FRIT TRANSPORT DEMONSTRATION

    International Nuclear Information System (INIS)

    Adamson, D.; Pickenheim, Bradley

    2008-01-01

    DWPF is considering replacing irregularly shaped glass frit with spherical glass beads in the Slurry Mix Evaporator (SME) process to decrease the yield stress of the melter feed (a non-Newtonian Bingham Plastic). Pilot-scale testing was conducted on spherical glass beads and glass frit to determine how well the glass beads would transfer when compared to the glass frit. Process Engineering Development designed and constructed the test apparatus to aid in the understanding and impacts that spherical glass beads may have on the existing DWPF Frit Transfer System. Testing was conducted to determine if the lines would plug with the glass beads and the glass frit slurry and what is required to unplug the lines. The flow loop consisted of vertical and horizontal runs of clear PVC piping, similar in geometry to the existing system. Two different batches of glass slurry were tested: a batch of 50 wt% spherical glass beads and a batch of 50 wt% glass frit in process water. No chemicals such as formic acid was used in slurry, only water and glass formers. The glass beads used for this testing were commercially available borosilicate glass of mesh size -100+200. The glass frit was Frit 418 obtained from DWPF and is nominally -45+200 mesh. The spherical glass beads did not have a negative impact on the frit transfer system. The transferring of the spherical glass beads was much easier than the glass frit. It was difficult to create a plug with glass bead slurry in the pilot transfer system. When a small plug occurred from setting overnight with the spherical glass beads, the plug was easy to displace using only the pump. In the case of creating a man made plug in a vertical line, by filling the line with spherical glass beads and allowing the slurry to settle for days, the plug was easy to remove by using flush water. The glass frit proved to be much more difficult to transfer when compared to the spherical glass beads. The glass frit impacted the transfer system to the point

  1. Cationic mobility in polystyrene sulfone exchangers - Application to the elution of a cation on an exchange column

    International Nuclear Information System (INIS)

    Menin, Jean-Pierre

    1969-01-01

    The aim of this work is to improve elutions and separations carried out on inorganic exchangers by selective electromigration of the ionic species to be displaced. To do this, it has been found indispensable to make a fundamental study of the mobility of cations in exchangers. As the field for this research we have chosen those organic exchangers whose structure and behaviour with respect to ion-exchange are much better known that in the case of their inorganic equivalents. We have related the idea of the equivalent conductivity to that of the cation mobility in the exchanger, and this has entailed determining the specific conductivity of the exchanger and the cation concentration in the resin. The results obtained have allowed us to draw up a hypothesis concerning the cation migration mechanism in the exchanger. The third part of our work has been the application of the preceding results to an operation on an ion-exchange column, viz. the elution by an acid solution of a single fixed ion, magnesium or strontium. This work has enabled us to show that the electromigration of a cation during its elution can markedly accelerate or retard this elution. (author) [fr

  2. Electro-Fenton decolourisation of dyes in an airlift continuous reactor using iron alginate beads.

    Science.gov (United States)

    Iglesias, O; Rosales, E; Pazos, M; Sanromán, M A

    2013-04-01

    In this study, electro-Fenton dye degradation was performed in an airlift continuous reactor configuration by harnessing the catalytic activity of Fe alginate gel beads. Electro-Fenton experiments were carried out in an airlift reactor with a working volume of 1.5 L, air flow of 1.5 L/min and 115 g of Fe alginate gel beads. An electric field was applied by two graphite bars connected to a direct current power supply with a constant potential drop. In this study, Lissamine Green B and Reactive Black 5 were selected as model dyes. Fe alginate gel beads can be used as an effective heterogeneous catalyst for the degradation of organic dyes in the electro-Fenton process, as they are more efficient than the conventional electrochemical techniques. At optimal working conditions (3 V and pH 2), the continuous process was performed. For both dyes, the degree of decolourisation increases when the residence time augments. Taking into account hydrodynamic and kinetic behaviour, a model to describe the reactor profile was obtained, and the standard deviation between experimental and theoretical data was lower than 6%. The results indicate the suitability of the electro-Fenton technique to oxidise polluted effluents in the presence of Fe alginate gel beads. Moreover, the operation is possible in a continuous airlift reactor, due to the entrapment of iron in the alginate matrix.

  3. Preparation of diclofenac-imprinted polymer beads for selective molecular separation in water.

    Science.gov (United States)

    Zhou, Tongchang; Kamra, Tripta; Ye, Lei

    2018-03-01

    Molecular imprinting technique is an attractive strategy to prepare materials for target recognition and rapid separation. In this work, a new type of diclofenac (DFC)-imprinted polymer beads was synthesized by Pickering emulsion polymerization using 2-(dimethylamino)ethyl methacrylate as the functional monomer. The selectivity and capacity of the molecularly imprinted polymers (MIPs) were investigated in aqueous solution. Equilibrium binding results show that the MIPs have a high selectivity to bind DFC in a wide range of pH values. Moreover, in liquid chromatography experiment, the imprinted polymer beads were packed into column to investigate the binding selectivity under nonequilibrium conditions. The retention time of DFC on the MIP column is significantly longer than its structural analogues. Also, retention of DFC on the MIP column was significantly longer than on the nonimprinted polymer column under aqueous condition. As the new MIP beads can be used to achieve direct separation of DFC from water, the synthetic method and the affinity beads developed in this work opened new possibilities for removing toxic chemicals from environmental and drinking water. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Improving Adsorption Deinking by Identifying the Optimum Balance between Polymer Beads and Deinking Chemistry

    Directory of Open Access Journals (Sweden)

    Krithika Ravi

    2016-01-01

    Full Text Available Ink removal from recovered paper is a very important process in paper and board recycling. The current deinking processes have made obvious contributions to the use of raw materials for the paper and board industries. In contrast to the flotation deinking process, in which small air bubbles are used to remove ink from the pulp, the novel and more energy-efficient method of adsorption deinking technique depends on the attachment and adsorption of ink particles on small polymer beads. The energy savings of adsorption deinking results from the fact that the process is efficient at greater stock consistencies, thus providing water conservation and savings. The present study was carried out to improve the adsorption deinking method by identifying the optimum balance between the deinking chemistry and the polymer beads. Different types of deinking solutions and polymer beads were used for this study with newsprints and mixture of newsprints and magazines. It was found that EGA 3000 solution and polyethylene terephthalate beads worked well with newspaper pulp.

  5. Preparation of acetaminophen capsules containing beads prepared by hot-melt direct blend coating.

    Science.gov (United States)

    Pham, Loan; Christensen, John M

    2014-02-01

    Twelve hydrophobic coating agents were assessed for their effects on drug release after coating sugar cores by a flexible hot-melt coating method using direct blending. Drug-containing pellets were also produced and used as cores. The cores were coated with single or double wax layers containing acetaminophen (APAP). The harder the wax, the slower the resultant drug releases from single-coated beads. Wax coating can be deposited on cores up to 28% of the beads final weight and reaching 58% with wax and drug. Carnauba-coated beads dissolved in approximately 6 h releasing 80% of the loaded drug. Applying another wax layer extended drug release over 20 h, while still delivering 80% of the loaded drug. When drug-containing pellets (33-58% drug loading) were used as cores, double wax-coated pellets exhibited a near zero-order drug release for 16 h, releasing 80% of the loaded drug delivering 18 mg/h. The simple process of hot-melt coating by direct blending of pellet-containing drug-coated formulations provides excellent options for immediate and sustained release formulations when higher lipid coating or drug loading is warranted. Predicted plasma drug concentration time profiles using convolution and in vitro drug release properties of the beads were performed for optimal formulations.

  6. Certain patterns of IgG adsorption by polystyrene bead surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Mamedov, M K

    1985-01-01

    The article reports on tests of domestic Soviet polystyrene beads that permit a simplified modification of the enzyme-adsorption method to identify the alpha hepatitis virus and its antibody in nonspecialized, general laboratories. Only patterns of Ig immunoglobulin adsorption were studied. Human IgG was conjugated with the radioactive isotope /sup 125/I by a chloramine method, with mean radioactivity and protein concentration measured frequently. Bovine serum albumin (BSA) and an anionic detergent Tween-20, and a phosphate-salt buffer with pH 5.8-8.2, were used to produce m-Ig and Ig. Adsorption involved incubation of the beads in various solutions, followed by measurement of their radioactivity. Results of several series of tests were subjected to Student-Fisher evaluation. This suggested that the presence of albumin in physiological concentrations in the solution had no important impact on m-Ig adsorption on the bead surface, which effectively adsorbed Ig from solutions without additional proteins, but also from Ig solutions containing serum albumin in physiological concentrations. Thus, it was possible to coat the beads with alpha Ig hepatitis virus. The Tween-20 weak detergent was effective for eliminating unwanted protein adsorption. 9 references, 3 figures.

  7. Development of a magnetic bead-based method for the collection of circulating extracellular vesicles.

    Science.gov (United States)

    Shih, Chun-Liang; Chong, Kowit-Yu; Hsu, Shih-Che; Chien, Hsin-Jung; Ma, Ching-Ting; Chang, John Wen-Cheng; Yu, Chia-Jung; Chiou, Chiuan-Chian

    2016-01-25

    Cells release different types of extracellular vesicles (EVs). These EVs contain biomolecules, including proteins and nucleic acids, from their parent cells, which can be useful for diagnostic applications. The aim of this study was to develop a convenient procedure to collect circulating EVs with detectable mRNA or other biomolecules. Magnetic beads coated with annexin A5 (ANX-beads), which bound to phosphatidylserine moieties on the surfaces of most EVs, were tested for their ability to capture induced apoptotic bodies in vitro and other phosphatidylserine-presenting vesicles in body fluids. Our results show that up to 60% of induced apoptotic bodies could be captured by the ANX-beads. The vesicles captured from cultured media or plasma contained amplifiable RNA. Suitable blood samples for EV collection included EDTA-plasma and serum but not heparin-plasma. In addition, EVs in plasma were labile to freeze-and-thaw cycles. In rodents xenografted with human cancer cells, tumor-derived mRNA could be detected in EVs captured from serum samples. Active proteins could be detected in EVs captured from ascites but not from plasma. In conclusion, we have developed a magnetic bead-based procedure for the collection of EVs from body fluids and proved that captured EVs contain biomolecules from their parent cells, and therefore have great potential for disease diagnosis. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Fabrication of large size alginate beads for three-dimensional cell-cluster culture

    Science.gov (United States)

    Zhang, Zhengtao; Ruan, Meilin; Liu, Hongni; Cao, Yiping; He, Rongxiang

    2017-08-01

    We fabricated large size alginate beads using a simple microfluidic device under a co-axial injection regime. This device was made by PDMS casting with a mold formed by small diameter metal and polytetrafluorothylene tubes. Droplets of 2% sodium alginate were generated in soybean oil through the device and then cross-linked in a 2% CaCl2 solution, which was mixed tween80 with at a concentration of 0.4 to 40% (w/v). Our results showed that the morphology of the produced alginate beads strongly depends on the tween80 concentration. With the increase of concentration of tween80, the shape of the alginate beads varied from semi-spherical to tailed-spherical, due to the decrease of interface tension between oil and cross-link solution. To access the biocompatibility of the approach, MCF-7 cells were cultured with the alginate beads, showing the formation of cancer cells clusters which might be useful for future studies.

  9. Effect of Temperature on Granulocyte and Monocyte Adsorption to Cellulose Acetate Beads.

    Science.gov (United States)

    Nishise, Shoichi; Takeda, Yuji; Abe, Yasuhiko; Sasaki, Yu; Nara, Hidetoshi; Asao, Hironobu; Ueno, Yoshiyuki

    2017-06-01

    Granulocyte and monocyte (GM) adsorptive apheresis (GMA) is an effective therapy for inflammatory disorders including inflammatory bowel disease (IBD). During GMA, the blood of a patient with IBD passes through a column to contact cellulose acetate (CA) beads at a temperature below body temperature, likely close to room temperature. Here we investigated the effect of temperature on GM adsorption to CA beads in vitro. We incubated peripheral blood with and without CA beads at 5°C, 25°C, 37°C, and 43°C and calculated the ratios of adsorbed GMs. The ratios of adsorbed GMs increased as the temperature was raised. Additionally, we measured complement activation fragment concentrations. C3a and C5a concentrations also increased as the temperature was raised, and C5a concentrations had a positive correlation with the ratios of adsorbed GMs. These results suggest that warming the column during GMA might increase GM adsorption to CA beads, thereby enhancing the clinical efficacy of GMA. © 2017 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.

  10. Differential clinical outcomes after 1 year versus 5 years in a randomised comparison of zotarolimus-eluting and sirolimus-eluting coronary stents (the SORT OUT III study)

    DEFF Research Database (Denmark)

    Maeng, Michael; Tilsted, Hans Henrik; Jensen, Lisette Okkels

    2014-01-01

    received two different types of drug-eluting stents. METHODS: We undertook this multicentre, open-label, randomised superiority trial at five percutaneous coronary intervention centres in Denmark. We randomly allocated 2332 eligible adult patients (≥18 years of age) with an indication for drug......-eluting stent implantation to the zotarolimus-eluting Endeavor Sprint stent (Medtronic, Santa Rosa, CA, USA) or the sirolimus-eluting Cypher Select Plus stent (Cordis, Johnson & Johnson, Warren, NJ, USA). Randomisation of participants was achieved by computer-generated block randomisation and a telephone...

  11. Self-organizing magnetic beads for biomedical applications

    International Nuclear Information System (INIS)

    Gusenbauer, Markus; Kovacs, Alexander; Reichel, Franz; Exl, Lukas; Bance, Simon; Özelt, Harald; Schrefl, Thomas

    2012-01-01

    In the field of biomedicine magnetic beads are used for drug delivery and to treat hyperthermia. Here we propose to use self-organized bead structures to isolate circulating tumor cells using lab-on-chip technologies. Typically blood flows past microposts functionalized with antibodies for circulating tumor cells. Creating these microposts with interacting magnetic beads makes it possible to tune the geometry in size, position and shape. We developed a simulation tool that combines micromagnetics and discrete particle dynamics, in order to design micropost arrays made of interacting beads. The simulation takes into account the viscous drag of the blood flow, magnetostatic interactions between the magnetic beads and gradient forces from external aligned magnets. We developed a particle–particle particle–mesh method for effective computation of the magnetic force and torque acting on the particles. - Highlights: ► We propose to use self-organized bead structures to isolate circulating tumor cells. ► Flexible ways are important to get a high probability of catching cancer cells. ► The beads make it possible to tune the geometry in size position and shape.

  12. Ecohydraulics of Strings and Beads in Bedrock Rivers

    Science.gov (United States)

    Wohl, E.

    2016-12-01

    Twenty years ago, Jack Stanford and others described rivers in bedrock canyons as resembling beads on a string when viewed in planform. The beads are relatively wide, low gradient river segments with floodplains, whereas the strings are the intervening steep, narrow river segments with minimal floodplain development. This pattern of longitudinal variations in channel and valley morphology along bedrock canyon rivers is very common, from small channels to major rivers such as the Colorado. Basic understanding of river ecosystems, as well as limited studies, indicates that the beads are more retentive and biologically productive. Although both strings and beads can provide habitat for diverse organisms, strings are more likely to serve as migration corridors, whereas beads provide spawning and nursery habitat, facilitate lateral (channel-floodplain) and vertical (channel-hyporheic) exchanges and associated habitat diversity, and retain dissolved and particulate organic matter. Recognition of the different characteristics and functions of strings and beads can be used to identify their spatial distribution along a river or within a river network and the hydraulically driven processes that sustain channel form, water quality, and biota within strings and beads. Diverse modeling approaches can then be used to quantify the fluxes of water and sediment needed to maintain these hydraulically driven processes. This conceptual framework is illustrated using examples from mountain streams in the Southern Rockies and canyon rivers in the southwestern United States.

  13. [Drug-eluting stent thrombosis and its pharmacological prevention].

    Science.gov (United States)

    Pershukov, I V; Batyraliev, T A

    2007-01-01

    The problem of drug eluting stents (DES) safety has been actively discussed throughout 2006 because of increase of frequency of development of late stent thromboses which were noted during almost 2 years after stenting. In December 2006 US Food and Drug Administration (FDA) advisory panel acknowledged increase of development of late stent thrombosis. At the same time FDA accepted new definition of stent-thrombosis suggested by the Academic Research Consortium. According to this definition thrombosis can be definite, probable and possible. Any unexplained death before end of follow-up in a trial should be considered thrombosis related. Recalculation of thrombosis rate using this definition caused pronounced increase of this parameter in previously conducted trials. Thrombosis rate rose from 0,6 to 3,3% for bare metal stents, from 0,8 to 3,6% for sirolimus eluting stents and from 1,3 to 3,5% for paclitaxel eluting stents. Professional cardiological and angiographical societies (ACC, AHA, SCAI) responding to FDA advisory panel published their proofs and vision of the problem of stent thrombosis. In February 2007 ACC, AHA, SCAI, American College of Surgeons and Association of Dentists published scientific bulletin in which described preventive measures aimed at lowering of risk of thrombosis development. This document contains strict recommendation to continue double antithrombotic therapy with aspirin and clopidogrel for 12 months after implantation of DES or abandonment of the use of this type of stents when long term double antithrombotic therapy is not possible.

  14. JASPAS programme task JC-4: Isotopic and isotope dilution analysis of spent fuel solutions by resin bead mass spectrometry

    International Nuclear Information System (INIS)

    Hayashi, N.; Terakado, S.; Kuno, Y.

    1988-05-01

    The use of resin beads for mass spectrometry of U and Pu has been extensively developed at Oak Ridge National Laboratory in the USA and tested in a number of intercomparison experiments between the Safeguards Analytical Laboratory (SAL) of the IAEA and the Power Reactor and Fuel Development Corporation (PNC) - Tokai Reprocessing Plant (TRP) in Japan. Resin beads represent a convenient way to concentrate the U and Pu in spent fuel dissolver solution samples from reprocessing facilities, with the added advantage that fission product elements and other actinides such as Am are removed. Measurements on the resin bead samples at SAL were performed on the ORNL-designed 2-Stage Mass Spectrometer. For the dried tracer samples, the U measurements were obtained on the VG54E instrument and the Pu results were obtained with the Finnigan MAT 261 of SAL. PNC/TRP used a VG54 mass spectrometer and obtained their mass fractionation correction factor for the resin bead measurements from the mixed tracer plus chemical standard resin bead samples. The Safeguards Laboratory (NMCC) used their MAT 260 instrument and obtained the fractionation correction factor from resin bead standards provided with the TIGR-82 programme. Both PNC/TRP and NMCC reported problems with obtaining a sufficient ion beam intensity with the resin bead samples. This problem was overcome by both labs and further improvements in the loading and measurement techniques can be expected to yield even better results. It has been demonstrated that the resin bed sampling method can provide results of sufficient quality for safeguards purposes. 2 refs, 3 figs, 16 tabs

  15. Enhancing cognate target elution efficiency in gel-free chemical proteomics

    Directory of Open Access Journals (Sweden)

    Branka Radic-Sarikas

    2015-12-01

    Full Text Available Gel-free liquid chromatography mass spectrometry coupled to chemical proteomics is a powerful approach for characterizing cellular target profiles of small molecules. We have previously described a fast and efficient elution protocol; however, altered target profiles were observed. We hypothesised that elution conditions critically impact the effectiveness of disrupting drug-protein interactions. Thus, a number of elution conditions were systematically assessed with the aim of improving the recovery of all classes of proteins whilst maintaining compatibility with immunoblotting procedures. A double elution with formic acid combined with urea emerged as the most efficient and generically applicable elution method for chemical proteomics

  16. Random glycopeptide bead libraries for seromic biomarker discovery

    DEFF Research Database (Denmark)

    Kracun, Stjepan Kresimir; Cló, Emiliano; Clausen, Henrik

    2010-01-01

    have developed a random glycopeptide bead library screening platform for detection of autoantibodies and other binding proteins. Libraries were build on biocompatible PEGA beads including a safety-catch C-terminal amide linker (SCAL) that allowed mild cleavage conditions (I(2)/NaBH(4) and TFA...... to other tumor glycoforms by on-bead enzymatic glycosylation reactions with recombinant glycosyltransferases. Hence, we have developed a high-throughput flexible platform for rapid discovery of O-glycopeptide biomarkers and the method has applicability in other types of assays such as lectin...

  17. The study of drug eluting biodegradable intravascular stent with antiproliferation agent-paclitaxel in preventing vascular restenosis

    International Nuclear Information System (INIS)

    Xiao Yueyong; Zhang Jinshan; Cui Fuzhai; Meng Bo

    2004-01-01

    Objective: To define the effect of drug eluting BIS with antiproliferation agent-paclitaxel in preventing vascular restenosis. Methods: Bare BIS and drug BIS with 60 μg paclitaxel were prepared. Both types of the BIS were implanted into the infrarenal restenosis aortas in canine models, and the animals were euthanized 6 weeks after implantation for histopathological, morphometric and immunohistochemical assessment. Results: The mean lumen area of bare BIS group was (77 586.5 ± 66.0) μm 2 , and lumen of paclitaxel eluting BIS group was (113 435.9 ±71.0) μm 2 . The mean neointima area of bare BIS group was (24 803 ± 56) μm 2 , and paclitaxel eluting BIS group was (12 931 ± 63) μm 2 . The PCNA-positive ratio was (38 ± 15)% in bare BIS group and (11 ± 0.31)% in paclitaxel eluting BIS group. The statistically significant difference between the two groups were noted (P<0.01). Conclusion: BIS as a vehicle of loading and releasing drugs could significantly inhibit the VSMC and neointimal hyperplasia with antiproliferation agent-paclitaxel. BIS is a promising and new strategy in preventing the restenosis

  18. X-ray induced DNA double strand break production and repair in mammalian cells as measured by neutral filter elution

    Energy Technology Data Exchange (ETDEWEB)

    Bradley, M O; Kohn, K W [National Institutes of Health, Bethesda, MD (USA)

    1979-10-01

    A neutral filter elution method was used for detecting DNA double strand breaks in mouse L1210 cells after X-ray. The assay detected the number of double strand breaks induced by as little as 1000 rad of X-ray. The rate of DNA elution through the filters under neutral conditions increased with X-ray dose. Certain conditions for deproteinization, pH, and filter type were shown to increase the assay's sensitivity. Hydrogen peroxide and Bleomycin also induced apparent DNA double strand breaks, although the ratios of double to single strand breaks varied from those produced by X-ray. The introduction of double strand cuts by HpA I restriction endonuclease in DNA lysed on filters resulted in a rapid rate of elution under neutral conditions, implying that the method can detect double strand breaks if they exist in the DNA. The eluted DNA banded with a double stranded DNA marker in cesium chloride. This evidence suggested that the assay detected DNA double strand breaks. L1210 cells were shown to rejoin most of the DNA double strand breaks induced by 5-10 krad of X-ray with a half-time of about 40 minutes. (author).

  19. A two-channel detection method for autofluorescence correction and efficient on-bead screening of one-bead one-compound combinatorial libraries using the COPAS fluorescence activated bead sorting system

    International Nuclear Information System (INIS)

    Hintersteiner, Martin; Auer, Manfred

    2013-01-01

    One-bead one-compound combinatorial library beads exhibit varying levels of autofluorescence after solid phase combinatorial synthesis. Very often this causes significant problems for automated on-bead screening using TentaGel beads and fluorescently labeled target proteins. Herein, we present a method to overcome this limitation when fluorescence activated bead sorting is used as the screening method. We have equipped the COPAS bead sorting instrument with a high-speed profiling unit and developed a spectral autofluorescence correction method. The correction method is based on a simple algebraic operation using the fluorescence data from two detection channels and is applied on-the-fly in order to reliably identify hit beads by COPAS bead sorting. Our method provides a practical tool for the fast and efficient isolation of hit beads from one-bead one-compound library screens using either fluorescently labeled target proteins or biotinylated target proteins. This method makes hit bead identification easier and more reliable. It reduces false positives and eliminates the need for time-consuming pre-sorting of library beads in order to remove autofluorescent beads. (technical note)

  20. K Basin sludge/resin bead separation test report

    International Nuclear Information System (INIS)

    Squier, D.M.

    1998-01-01

    The K Basin sludge is an accumulation of fuel element corrosion products, organic and inorganic ion exchange materials, canister gasket materials, iron and aluminum corrosion products, sand, dirt and minor amounts of other organic material. The sludge will be collected and treated for storage and eventual disposal. This process will remove the large solid materials by a 1/4 inch screen. The screened material will be subjected to nitric acid in a chemical treatment process. The organic ion exchange resin beads produce undesirable chemical reactions with the nitric acid. The resin beads must be removed from the bulk material and treated by another process. An effective bead separation method must extract 95% of the resin bead mass without entraining more than 5% of the other sludge component mass. The test plan I-INF-2729, ''Organic Ion Exchange Resin Separation Methods Evaluation,'' proposed the evaluation of air lift, hydro cyclone, agitated slurry and elutriation resin bead separation methods. This follows the testing strategy outlined in section 4.1 of BNF-2574, ''Testing Strategy to Support the Development of K Basins Sludge Treatment Process''. Engineering study BNF-3128, ''Separation of Organic Ion Exchange Resins from Sludge,'' Rev. 0, focused the evaluation tests on a method that removed the fine sludge particles by a sieve and then extracted the beads by means of a elutriation column. Ninety-nine percent of the resin beads are larger than 125 microns and 98.5 percent are 300 microns and larger. Particles smaller than 125 microns make up the largest portion of sludge in the K Basins. Eliminating a large part of the sludge's non-bead component will reduce the quantity that is lifted with the resin beads in the elutriation column. Resin bead particle size distribution measurements are given in Appendix A The Engineering Testing Laboratory conducted measurements of a elutriation column's ability to extract resin beads from a sieved, non-radioactive sludge

  1. Efficient functionalization of poly(styrene) beads immobilized metal ...

    Indian Academy of Sciences (India)

    Three types of new bead-shaped heterogeneous nanoparticle (NP) catalysts were synthesized by sim- plified procedures .... and Ag+-doped titanium. Therefore, removal ..... References. 1. Storhoff J J, Elghanian R, Mucic R C, Mirkin C A and.

  2. An approach to implement virtual channels for flowing magnetic beads

    International Nuclear Information System (INIS)

    Tang, Shih-Hao; Chiang, Hung-Wei; Hsieh, Min-Chien; Chang, Yen-Di; Yeh, Po-Fan; Tsai, Jui-che; Shieh, Wung-Yang

    2014-01-01

    This work demonstrates the feasibility of a novel microfluidic system with virtual channels formed by ‘walls’ of magnetic fields, including collecting channels, transporting channels and function channels. The channels are defined by the nickel patterns. With its own ferromagnetism, nickel can be magnetized using an external magnetic field; the nickel structures then generate magnetic fields that can either guide or trap magnetic beads. A glass substrate is sandwiched between the liquid containing magnetic beads and the chip with nickel structures, preventing the liquid from directly contacting the nickel. In this work, collecting channels, transporting channels and function channels are displayed sequentially. In the collecting channel portion, channels with different shapes are compared. Next, in the transporting channel portion we demonstrate I-, S- and Y-shaped channels can steer magnetic beads smoothly. Finally, in the function channel portion, a switchable trapping channel implemented with a bistable mechanism performs the passing and blocking of a magnetic bead. (paper)

  3. Standard specification for beaded process glass pipe and fittings

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This specification covers chemically resistant, low expansion Type-I borosilicate glass, Class A, (see Specification E 438) used to manufacture beaded end flanged-glass pipe and fittings for pressure and vacuum applications.

  4. An integrated open-cavity system for magnetic bead manipulation.

    Science.gov (United States)

    Abu-Nimeh, F T; Salem, F M

    2013-02-01

    Superparamagnetic beads are increasingly used in biomedical assays to manipulate, transport, and maneuver biomaterials. We present a low-cost integrated system designed in bulk CMOS to manipulate and separate biomedical magnetic beads. The system consists of 8 × 8 coil-arrays suitable for single bead manipulation, or collaborative multi-bead manipulation, using pseudo-parallel executions. We demonstrate the flexibility of the design in terms of different coil sizes, DC current levels, and layout techniques. In one array module example, the size of a single coil is 30 μm × 30 μm and the full array occupies an area of 248 μm × 248 μm in 0.5 μm CMOS technology. The programmable DC current source supports 8 discrete levels up to 1.5 mA. The total power consumption of the entire module is 9 mW when running at full power.

  5. Selective manipulation of superparamagnetic beads by a magnetic microchip

    KAUST Repository

    Gooneratne, Chinthaka Pasan; Yassine, Omar; Giouroudi, Ioanna; Kosel, Jü rgen

    2013-01-01

    In this paper, a magnetic microchip (MMC) is presented, to first trap and then selectively manipulate individual, superparamagnetic beads (SPBs) to another trapping site. Trapping sites are realized through soft magnetic micro disks made of Ni80Fe20

  6. TiO₂ beads and TiO₂-chitosan beads for urease immobilization.

    Science.gov (United States)

    Ispirli Doğaç, Yasemin; Deveci, Ilyas; Teke, Mustafa; Mercimek, Bedrettin

    2014-09-01

    The aim of the present study is to synthesize TiO2 beads for urease immobilization. Two different strategies were used to immobilize the urease on TiO2 beads. In the first method (A), urease enzyme was immobilized onto TiO2 beads by adsorption and then crosslinking. In the second method (B), TiO2 beads were coated with chitosan-urease mixture. To determine optimum conditions of immobilization, different parameters were investigated. The parameters of optimization were initial enzyme concentration (0.5; 1; 1.5; 2mg/ml), alginate concentration (1; 2; 3%), glutaraldehyde concentration (1; 2; 3% v/v) and chitosan concentration (2; 3; 4 mg/ml). The optimum enzyme concentrations were determined as 1.5mg/ml for A and 1.0mg/ml for B. The other optimum conditions were found 2.0% (w/v) for alginate concentration (both A and B); 3.0mg/ml for chitosan concentration (B) and 2.0% (v/v) for glutaraldehyde concentration (A). The optimum temperature (20-60°C), optimum pH (3.0-10.0), kinetic parameters, thermal stability (4-70°C), pH stability (4.0-9.0), operational stability (0-230 min) and reusability (20 times) were investigated for characterization. The optimum temperatures were 30°C (A), 40°C (B) and 35°C (soluble). The temperature profiles of the immobilized ureases were spread over a large area. The optimum pH values for the soluble urease and immobilized urease prepared by using methods (A) and (B) were found to be 7.5, 7.0, 7.0, respectively. The thermal stabilities of immobilized enzyme sets were studied and they maintained 50% activity at 65°C. However, at this temperature free urease protected only 15% activity. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Sensitive detection of nucleic acids by PNA hybridization directed co-localization of fluorescent beads

    DEFF Research Database (Denmark)

    Shiraishi, Takehiko; Deborggraeve, Stijn; Büscher, Philippe

    2011-01-01

    )avidin-coated fluorescent beads, differing in size and color [green beads (1 µm) and red beads (5.9 µm)], thereby allowing distinct detection of each PNA probe by conventional fluorescence microscopy. These two PNA beads showed easily detectable co-localization when simultaneously hybridizing to a target nucleic acid...

  8. Ferrite bead effect on Class-D amplifier audio quality

    OpenAIRE

    Haddad , Kevin El; Mrad , Roberto; Morel , Florent; Pillonnet , Gael; Vollaire , Christian; Nagari , Angelo

    2014-01-01

    International audience; This paper studies the effect of ferrite beads on the audio quality of Class-D audio amplifiers. This latter is a switch-ing circuit which creates high frequency harmonics. Generally, a filter is used at the amplifier output for the sake of electro-magnetic compatibility (EMC). So often, in integrated solutions, this filter contains ferrite beads which are magnetic components and present nonlinear behavior. Time domain measurements and their equivalence in frequency do...

  9. Comparison of an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent for the treatment of coronary artery stenosis (ABSORB II)

    DEFF Research Database (Denmark)

    Serruys, Patrick W; Chevalier, Bernard; Sotomi, Yohei

    2016-01-01

    BACKGROUND: No medium-term data are available on the random comparison between everolimus-eluting bioresorbable vascular scaffolds and everolimus-eluting metallic stents. The study aims to demonstrate two mechanistic properties of the bioresorbable scaffold: increase in luminal dimensions as a re...

  10. Effect of Post-Dilatation Following Primary PCI With Everolimus-Eluting Bioresorbable Scaffold Versus Everolimus-Eluting Metallic Stent Implantation

    DEFF Research Database (Denmark)

    Yamaji, Kyohei; Brugaletta, Salvatore; Sabaté, Manel

    2017-01-01

    OBJECTIVES: This study sought to investigate the effect of post-dilatation on angiographic and intracoronary imaging parameters in the setting of primary percutaneous coronary intervention comparing the everolimus-eluting bioresorbable scaffold (BRS) with the everolimus-eluting metallic stent (EE...

  11. Preparation of Bio-beads and Their Atrazine Degradation Characteristics

    Institute of Scientific and Technical Information of China (English)

    BI Hai-tao; ZHANG Lan-ying; LIU Na; ZHU Bo-lin

    2011-01-01

    Screened atrazine-mineralizing bacterium-Pseudomonas W4 was embedded inside an improved PVAH3BO3 embedment matrix to make bio-beads to degrade atrazine. The atrazine degradation characteristics were studied. The preparation procedure of bio-beads was as follows: (1) preparing a mixture of 100, 12.5, 10, 1.5 and 1 g/L PVA, bentonite(Ca), activated carbon powder, sodium alginate and centrifuged Pseudomonas W4 bacterium, respectively; (2) the mixture was dropped into a gently stirred cross linker solution(pH=6.7) and cured at 10 ℃ for 24 h.The optimal atrazine degradation conditions by bio-beads were as follows: pH=7, the auxiliary carbon source was glucose, and the concentration of glucose was greater than 325 mg/L. The bio-beads demonstrated stronger tolerance ability than the free microorganism to the increase of PCBs, hydrogen ion and hydroxide ion. SEM images show the uniform distribution of the microorganism inside bio-beads and the porous cross-linked structure of bio-beads which provides excellent mass transfer capacity.

  12. Effects of Magnetic Particles Entrance Arrange-ments on Mixing Efficiency of a Magnetic Bead Micromixer

    Institute of Scientific and Technical Information of China (English)

    Reza Kamali∗; Seyed Alireza Shekoohi; Alireza Binesh

    2014-01-01

    In this study, a computer code is developed to numerically investigate a magnetic bead micromixer under different conditions. The micromixer consists of a microchannel and numerous micro magnetic particles which enter the micromixer by fluid flows and are actuated by an alternating magnetic field normal to the main flow. An important feature of micromixer which is not considered before by researchers is the particle entrance arrangement into the micromixer. This parameter could effectively affect the micromixer efficiency. There are two general micro magnetic particle entrance arrangements in magnetic bead micromixers: determined position entrance and random position entrance. In the case of determined position entrances, micro magnetic particles enter the micromixer at specific positions of entrance cross section. However, in a random position entrance, particles enter the microchannel with no order. In this study mixing efficiencies of identical magnetic bead micromixers which only differ in particle entrance arrangement are numerically investigated and compared. The results reported in this paper illustrate that the prepared computer code can be one of the most powerful and beneficial tools for the magnetic bead micromixer performance analysis. In addition, the results show that some features of the magnetic bead micromixer are strongly affected by the entrance arrangement of the particles.

  13. Zotarolimus-eluting durable-polymer-coated stent versus a biolimus-eluting biodegradable-polymer-coated stent in unselected patients undergoing percutaneous coronary intervention (SORT OUT VI)

    DEFF Research Database (Denmark)

    Raungaard, Bent; Jensen, Lisette Okkels; Tilsted, Hans-Henrik

    2015-01-01

    BACKGROUND: New-generation drug-eluting coronary stents have reduced the risk of coronary events, especially in patients with complex disease or lesions. To what extent different stent platforms, polymers, and antiproliferative drugs affect outcomes, however, is unclear. We investigated the safety...... and efficacy of a third-generation stent by comparing a highly biocompatible durable-polymer-coated zotarolimus-eluting stent with a biodegradable-polymer-coated biolimus-eluting stent. METHODS: This open-label, randomised, multicentre, non-inferiority trial was done at three sites across western Denmark. All......-polymer zotarolimus-eluting stent or the biodegradable-polymer biolimus-eluting stent. The primary endpoint was a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion) and efficacy (target-lesion revascularisation) at 12 months, analysed by intention to treat...

  14. Effects of gelling bath on the physical properties of alginate gel beads and the biological characteristics of entrapped HepG2 cells.

    Science.gov (United States)

    Sun, Dongsheng; Liu, Yang; Wu, Hao; Ren, Ying; Ma, Xiaojun; Wu, Huijian; Sun, Guangwei

    2018-03-01

    Optimizing alginate gel beads is necessary to support the survival, proliferation, and function of entrapped hepatocytes. In this study, gelling bath was modified by decreasing calcium ion concentration and increasing sodium ion concentration. Alginate gel beads (using 36% G sodium alginate) prepared in the modified gelling bath had more homogeneous structure and better mass transfer properties compared with the traditional gelling bath that contains only calcium ions. Moreover, alginate gel beads generated in the modified gelling bath could significantly promote the HepG2 cell proliferation and the growth of cell spheroids, and maintain the albumin secretion ability similar to alginate gel beads prepared in the traditional gelling bath with only calcium ions. The mass transfer properties and cell proliferation were similar in ALG beads with different M/G ratio (36% G and 55% G) generated in the modified gelling bath, whereas they were significantly increased compared with alginate gel beads (55% G) in traditional gelling bath. These results indicated that adjusting the gelling bath was a simple and convenient method to enhance the mass transfer properties of alginate gel beads for 3D hepatocyte culture, which might provide more hepatocytes for the bioartificial liver support system. © 2017 International Union of Biochemistry and Molecular Biology, Inc.

  15. A planar conducting micro-loop structure for transportation of magnetic beads: An approach towards rapid sensing and quantification of biological entities

    KAUST Repository

    Gooneratne, Chinthaka Pasan

    2012-03-01

    Magnetic beads are utilized effectively in a wide variety of medical applications due to their small size, biocompatibility and large surface to volume ratio. Microfluidic lab-on-a-chip (LOC) devices, which utilize magnetic beads, are promising tools for accurate and rapid cell sorting and counting. Effective manipulation of beads is a critical factor for the performance of LOC devices. In this paper we propose a planar conducting micro-loop structure to trap, manipulate and transport magnetic beads. Current through the micro-loops produces magnetic field gradients that are proportional to the force required to manipulate the beads. Numerical analyses were performed to study the magnetic forces and their spatial distributions. Experimental results showed that magnetic beads could not only be transported towards a target region, e.g., for sensing purposes, but also the trapping rate could be increased by switching current between the different loops in the micro-loop structure. This method could lead to rapid and accurate quantification of biological entities tagged with magnetic beads. Copyright © 2012 American Scientific Publishers. All rights reserved.

  16. Anti-Inflammatory Effect of Gallic Acid-Eluting Stent in a Porcine Coronary Restenosis Model

    Science.gov (United States)

    Seob Lim, Kyung; Park, Jun-Kyu; Ho Jeong, Myung; Ho Bae, In; Sung Park, Dae; Won Shim, Jae; Ha Kim, Jung; Kuk Kim, Hyun; Soo Kim, Sung; Sun Sim, Doo; Joon Hong, Young; Han Kim, Ju; Ahn, Youngkeun

    2018-01-01

    Background Gallic acid (3,4,5-trihydroxybenzoic acid) is a natural polyphenol and strong natural antioxidant found abundantly in red wine and green tea. The aim of this study was to examine the anti-inflammatory effect of a novel gallic acid-eluting stent in a porcine coronary restenosis model. Methods Fifteen pigs were randomized into three groups; in which a total of 30 coronary arteries (10 in each group) were implanted with gallic acid-eluting stents (GESs, n = 10), gallic acid and sirolimus-eluting stents (GSESs, n = 10), or sirolimus-eluting stents (SESs, n = 10). Histopathologic analysis was performed 28 days after stenting. Results There were no significant differences in injury score and fibrin score among the groups, however there were significant differences in the internal elastic lamina (4.0 ± 0.83 mm2 in GES vs. 3.0 ± 0.53 mm2 in GSES vs. 4.6 ± 1.43 mm2 in SES, p < 0.0001), lumen area (2.3 ± 0.49 mm2 in GES vs. 1.9 ± 0.67 mm2 in GSES vs. 2.9 ± 0.56 mm2 in SES, p < 0.0001), neointimal area (1.7 ± 0.63 mm2 in GES vs. 1.1 ± 0.28 mm2 in GSES vs. 1.7 ± 1.17 mm2 in SES, p < 0.05), and percent area of stenosis (42.4% ± 9.22% in GES vs. 38.2% ± 12.77% in GSES vs. 33.9% ± 15.64% in SES, p < 0.05). The inflammation score was significantly lower in the GES and GSES groups compared to that in the SES group [1.0 (range: 1.0 to 2.0) in GES vs. 1.0 (range: 1.0 to 1.0) in GSES vs. 1.5 (range: 1.0 to 3.0) in SES, p < 0.05]. Conclusions The GES group had a greater percent area of stenosis than the SES group. Although gallic acid in the GES and GSES groups did not show a synergistic effect in suppressing neointimal hyperplasia, it resulted in greater inhibition of the inflammatory reaction in the porcine coronary restenosis model than in the SES group. PMID:29844643

  17. Spectral Analysis Related to Bare-Metal and Drug-Eluting Coronary Stent Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Rose Mary Ferreira Lisboa da, E-mail: roselisboa@cardiol.br [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Silva, Carlos Augusto Bueno [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Greco, Otaviano José [Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Moreira, Maria da Consolação Vieira [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil)

    2014-08-15

    The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia. To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent. This study assessed 61 patients (mean age, 64.0 years; 35 men) with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform), measuring the low-frequency (LF) and high-frequency (HF) components, and the LF/HF ratio before and during the procedure. Bare-metal stent was implanted in 34 patients, while the others received drug-eluting stents. The right coronary artery was approached in 21 patients, the left anterior descending, in 28, and the circumflex, in 9. As compared with the pre-stenting period, all patients showed an increase in LF and HF during stent implantation (658 versus 185 ms2, p = 0.00; 322 versus 121, p = 0.00, respectively), with no change in LF/HF. During stent implantation, LF was 864 ms2 in patients with bare-metal stents, and 398 ms2 in those with drug-eluting stents (p = 0.00). The spectral analysis of heart rate variability showed no association with diabetes mellitus, family history, clinical presentation, beta-blockers, age, and vessel or its segment. Stent implantation resulted in concomitant sympathetic and vagal activations. Diabetes mellitus, use of beta-blockers, and the vessel approached showed no influence on the spectral analysis of heart rate variability. Sympathetic activation was lower during the implantation of drug-eluting stents.

  18. Antibiotic eluting clay mineral (Laponite®) for wound healing application: an in vitro study.

    Science.gov (United States)

    Ghadiri, M; Chrzanowski, W; Rohanizadeh, R

    2014-11-01

    Different materials in form of sponge, hydrogel and film have been developed and formulated for treating and dressing burn wounds. In this study, the potential of Laponite, a gel forming clay, in combination with an antimicrobial agent (mafenide), as a wound dressing material was tested in vitro. Laponite/mafenide (Lap/Maf) hydrogel was formulated in three different ratios of Lap/Maf 1:1, 1:2, 1:3. Laponite/mafenide/alginate (Lap/Maf/Alg) film was also formulated by combining Lap/Maf gel (1:1) with alginate. Intercalation rate of mafenide into the layers of Laponite nanoparticles and physico-chemical properties, including wound dressing characteristics of materials were studied using various analytical methods. Furthermore, the degradation of materials and the release profile of mafenide were investigated in simulated wound exudates fluid and antibacterial effectiveness of the eluted mafenide was tested on a range of bacterial species. The cytotoxicity of materials was also evaluated in skin fibroblast culture. The results showed that mafenide molecules were intercalated between the nano-sized layers of Laponite. The eluted mafenide showed active antibacterial effects against all three tested bacteria. All intercalated mafenide released from Lap/Maf 1:1 and 1:2 gel formulations and nearly 80% release from 1:3 formulation during test period. No significant difference was observed in release profile of mafenide between Lap/Maf/Alg film and Lap/Maf formulations. Wound dressing tests on Lap/Maf/Alg film showed it is a breathable dressing and has capacity to absorb wound exudates. The study showed that prepared Lap/Maf composite has the potential to be used as an antibiotic eluting gel or film for wound healing application. Additionally, Laponite has shown benefits in wound healing processes by releasing Mg(2+) ions and thereby reducing the cytotoxic effect of mafenide on fibroblast cells.

  19. Prediction of bead area contact load at the tire-wheel interface using NASTRAN

    Science.gov (United States)

    Chen, C. H. S.

    1982-01-01

    The theoretical prediction of the bead area contact load at the tire wheel interface using NASTRAN is reported. The application of the linear code to a basically nonlinear problem results in excessive deformation of the structure and the tire-wheel contact conditions become impossible to achieve. A psuedo-nonlinear approach was adopted in which the moduli of the cord reinforced composite are increased so that the computed key deformations matched that of the experiment. Numerical results presented are discussed.

  20. Biodegradable-Polymer Biolimus-Eluting Stents versus Durable-Polymer Everolimus-Eluting Stents at One-Year Follow-Up: A Registry-Based Cohort Study.

    Science.gov (United States)

    Parsa, Ehsan; Saroukhani, Sepideh; Majlessi, Fereshteh; Poorhosseini, Hamidreza; Lofti-Tokaldany, Masoumeh; Jalali, Arash; Salarifar, Mojtaba; Nematipour, Ebrahim; Alidoosti, Mohammad; Aghajani, Hassan; Amirzadegan, Alireza; Kassaian, Seyed Ebrahim

    2016-04-01

    We compared outcomes of percutaneous coronary intervention patients who received biodegradable-polymer biolimus-eluting stents with those who received durable-polymer everolimus-eluting stents. At Tehran Heart Center, we performed a retrospective analysis of the data from January 2007 through December 2011 on 3,270 consecutive patients with coronary artery disease who underwent percutaneous coronary intervention with the biodegradable-polymer biolimus-eluting stent or the durable-polymer everolimus-eluting stent. We excluded patients with histories of coronary artery bypass grafting or percutaneous coronary intervention, acute ST-segment-elevation myocardial infarction, or the implantation of 2 different stent types. Patients were monitored for 12 months. The primary endpoint was a major adverse cardiac event, defined as a composite of death, nonfatal myocardial infarction, and target-vessel and target-lesion revascularization. Durable-polymer everolimus-eluting stents were implanted in 2,648 (81%) and biodegradable-polymer biolimus-eluting stents in 622 (19%) of the study population. There was no significant difference between the 2 groups (2.7% vs 2.7%; P=0.984) in the incidence of major adverse cardiac events. The cumulative adjusted probability of major adverse cardiac events in the biodegradable-polymer biolimus-eluting stent group did not differ from that of such events in the durable-polymer everolimus-eluting stent group (hazard ratio=0.768; 95% confidence interval, 0.421-1.44; P=0.388). We conclude that in our patients the biodegradable-polymer biolimus-eluting stent was as effective and safe, during the 12-month follow-up period, as was the durable-polymer everolimus-eluting stent.

  1. A new fabrication process for uniform SU-8 thick photoresist structures by simultaneously removing edge bead and air bubbles

    International Nuclear Information System (INIS)

    Lee, Hun; Lee, Kangsun; Ahn, Byungwook; Xu, Jing; Xu, Linfeng; Oh, Kwang W

    2011-01-01

    This paper proposes a new SU-8 fabrication process to simultaneously remove edge bead and tiny air bubbles by spraying out edge bead removal (EBR) fluid over the entire surface of photoresist. In particular, the edge bead and air bubbles can cause an air gap between a film mask and a photoresist surface during UV exposure. The diffraction effect of UV light by the air gap leads to inaccurate and non-uniform SU-8 patterns. In this study, we demonstrate a simple method using EBR treatment to simultaneously eliminate the edge bead at the edge of wafer and tiny air bubbles inside SU-8. The profiles of thickness variation of SU-8 films with/without the EBR treatment are measured. The results show that the proposed EBR treatment can successfully remove the edge bead and air bubbles over the entire SU-8 films. The average pattern uniformity of SU-8 is improved from 50.5% to 11.3% in the case of 200 µm thickness. This method is simple and inexpensive, compared to a standard EBR process, because it does not require specialized equipment and it can be applied regardless of substrate geometry (e.g. circular wafer and rectangular slide glass).

  2. Effects of Heat Input and Bead Generation Methods on Finite Element Analysis of Multi-Pass Welding Process

    Energy Technology Data Exchange (ETDEWEB)

    Park, Won Dong; Kim, Ji Hoon; Bahn, Chi Bum [Pusan National University, Busan (Korea, Republic of)

    2016-10-15

    Welding residual stresses are determined by various factors such as heat input, initial temperature of molten bead, heating time, cooling time, cooling conditions, and boundary conditions. In this study, a sensitivity analysis was performed to find the major factors and reasonable assumptions for simulation. Two-dimensional axisymmetric simulation was conducted by using commercial finite element analysis program ABAQUS, for multi-pass Alloy 82 welds in a 304 Stainless Steel and SA-105 Carbon Steel. The major object is to evaluate effects of the heat input methods and weld bead generation methods on the welding residual stress distribution. Totally four kinds of methods were compared. From the previous results, we could make the following conclusions. 1. Although there are non-negligible differences in HAZ depending on heat input method, welding residual stress distributions have roughly similar trends. However, it is needed to perform the more exact analysis to apply heat energy more carefully into the individual bead. 2. Residual stress distribution were similar for the two weld bead generation technique. However, overlapping was happened when element birth technique was applied. Effects of overlapping could not ignore as deformation increases. However, overlapping problem was avoided when quiet element technique was used. 3. Since existence of inactive bead elements, inaccurate weld residual stresses could be occurred in boundaries of previous and next weld elements in case of quiet element technique.

  3. Influence of heat input on weld bead geometry using duplex stainless steel wire electrode on low alloy steel specimens

    Directory of Open Access Journals (Sweden)

    Ajit Mondal

    2016-12-01

    Full Text Available Gas metal arc welding cladding becomes a popular surfacing technique in many modern industries as it enhances effectively corrosion resistance property and wear resistance property of structural members. Quality of weld cladding may be enhanced by controlling process parameters. If bead formation is found acceptable, cladding is also expected to be good. Weld bead characteristics are often assessed by bead geometry, and it is mainly influenced by heat input. In this paper, duplex stainless steel E2209 T01 is deposited on E250 low alloy steel specimens with 100% CO2 gas as shielding medium with different heats. Weld bead width, height of reinforcement and depth of penetration are measured. Regression analysis is done on the basis of experimental data. Results reveal that within the range of bead-on-plate welding experiments done, parameters of welding geometry are on the whole linearly related with heat input. A condition corresponding to 0.744 kJ/mm heat input is recommended to be used for weld cladding in practice.

  4. Simulation of elution profiles in liquid chromatography - II: Investigation of injection volume overload under gradient elution conditions applied to second dimension separations in two-dimensional liquid chromatography.

    Science.gov (United States)

    Stoll, Dwight R; Sajulga, Ray W; Voigt, Bryan N; Larson, Eli J; Jeong, Lena N; Rutan, Sarah C

    2017-11-10

    An important research direction in the continued development of two-dimensional liquid chromatography (2D-LC) is to improve the detection sensitivity of the method. This is especially important in applications where injection of large volumes of effluent from the first dimension ( 1 D) column into the second dimension ( 2 D) column leads to severe 2 D peak broadening and peak shape distortion. For example, this is common when coupling two reversed-phase columns and the organic solvent content of the 1 D mobile phase overwhelms the 2 D column with each injection of 1 D effluent, leading to low resolution in the second dimension. In a previous study we validated a simulation approach based on the Craig distribution model and adapted from the work of Czok and Guiochon [1] that enabled accurate simulation of simple isocratic and gradient separations with very small injection volumes, and isocratic separations with mismatched injection and mobile phase solvents [2]. In the present study we have extended this simulation approach to simulate separations relevant to 2D-LC. Specifically, we have focused on simulating 2 D separations where gradient elution conditions are used, there is mismatch between the sample solvent and the starting point in the gradient elution program, injection volumes approach or even exceed the dead volume of the 2 D column, and the extent of sample loop filling is varied. To validate this simulation we have compared results from simulations and experiments for 101 different conditions, including variation in injection volume (0.4-80μL), loop filling level (25-100%), and degree of mismatch between sample organic solvent and the starting point in the gradient elution program (-20 to +20% ACN). We find that that the simulation is accurate enough (median errors in retention time and peak width of -1.0 and -4.9%, without corrections for extra-column dispersion) to be useful in guiding optimization of 2D-LC separations. However, this requires that real

  5. Comparative studies of Iodo-bead and chloramine-T methods for the radioiodination of human alpha-fetoprotein

    International Nuclear Information System (INIS)

    Lee, D.S.C.; Griffiths, B.W.

    1984-01-01

    Human alpha-fetoprotein (h-AFP) of iodination grade was radiolabeled with Na 125 I by chloramine-T (conventional method) and by Iodo-bead (solid-phase method) under standard and varied conditions, such as quantity of h-AFP and volume of the reaction mixture. The authors have modified the chloramine-T method and developed a protocol for the Iodo-bead method of iodination. The results show that while the chloramine-T method yields radiolabeled h-AFP of apparently 40% higher specific radioactivity (SR) than those of the Iodo-bead method, the latter appears to be a simpler, more controllable and milder method, giving rise to a more stable population of [ 125 I]h-AFP. This is supported by the results of radioactive counting of [ 125 I]h-AFP collected from a Sephadex G-50 column after radioiodination, storage stability and immunoreactivity with anti-h-AFP. (Auth.)

  6. Permittivity and performance of dielectric pads with sintered ceramic beads in MRI: early experiments and simulations at 3 T.

    Science.gov (United States)

    Luo, Wei; Lanagan, Michael T; Sica, Christopher T; Ryu, Yeunchul; Oh, Sukhoon; Ketterman, Matthew; Yang, Qing X; Collins, Christopher M

    2013-07-01

    Passive dielectric materials have been used to improve aspects of MRI by affecting the distribution of radiofrequency electromagnetic fields. Recently, interest in such materials has increased with the number of high-field MRI sites. Here, we introduce a new material composed of sintered high-permittivity ceramic beads in deuterated water. This arrangement maintains the ability to create flexible pads for conforming to individual subjects. The properties of the material are measured and the performance of the material is compared to previously used materials in both simulation and experiment at 3 T. Results show that both permittivity of the beads and effect on signal-to-noise ratio and required transmit power in MRI are greater than those of materials consisting of ceramic powder in water. Importantly, use of beads results in both higher permittivity and lower conductivity than use of powder. Copyright © 2012 Wiley Periodicals, Inc.

  7. Chitosan metal-crosslinked beads applied for n-alkylmonoamines removal from aqueous solutions – a thermodynamic study

    International Nuclear Information System (INIS)

    Oliveira, Margarete; Simoni, Jose A.; Airoldi, Claudio

    2014-01-01

    Highlights: • Chitosan beads were successfully synthesized with divalent cations. • Well-formed bead structures containing cations act as acceptor electron sites. • n-Alkylmonoamine/bead interactions are favorably sorbed at the solid/liquid interface. • The thermodynamic data were favorably obtained from calorimetric titrations. • Crosslinked metal–chitosan beads can remove amine-like substances from an ecosystem. - Abstract: Chitosan has ability in coordinating divalent cations when immersed in crosslinked beads, after dripping: (i) chitosan gel into a copper solution, (ii) nickel chitosan gel into sodium hydroxide and (iii) chitosan/cobalt gel into sodium tripolyphosphate. The amounts of (1.82; 1.27 and 0.44) mmol · g −1 for copper, nickel and cobalt cations in these well-formed structures were determined, to give nitrogen/metal ratios of 3.52; 2.09 and 8.51, indicating the least effectiveness for cobalt in the coordination. Copper cation is well-adjusted in the coordination model through free amino and hydroxyl electron pairs, while amino and acetamino groups for nickel and cobalt were used. The chitosan–hydrogen bond breaking in bead formation caused decreases in crystallinity to yield amorphous structures for cobalt and nickel. The water mass fraction released during heating depends on the hydration of the cations, with the highest value of 0.20 for cobalt. The quantitative aspects of the interaction among cations on beads and basic n-alkylmonoamines determined via sorption batch methodology adjusted to the Langmuir isothermal model, with maximum sorption quantities to saturate nickel of (2.50; 2.38; 2.03; 1.79) mmol · g −1 and copper of (2.59; 2.29; 2.28; 1.92) mmol · g −1 for ethyl- propyl-, butyl- and pentylamines, respectively. The interaction energies quantitatively determined from isothermal titration calorimetry (ITC) at the solid/liquid interface resulted in exothermic enthalpic values. These negative enthalpy values combined to

  8. Synthesis of magnetic hollow silica using polystyrene bead as a template

    International Nuclear Information System (INIS)

    Wu, W.; Caruntu, D.; Martin, A.; Yu, M.H.; O'Connor, C.J.; Zhou, W.L.; Chen, J.-F.

    2007-01-01

    In this paper, we report a new route to synthesize novel magnetic hollow silica nanospheres (MHSNs) using polystyrene particles as sacrificial templates, and TEOS and Fe 3 O 4 as precursors. TEM, EDS, XRD, and SQUID were applied to characterize MHSNs. TEM and EDS results show that the MHSNs consist of about 200 nm of hollow cores and ∼35 nm shells with ∼10 nm of Fe 3 O 4 nanoparticles embedded. The polystyrene beads were successfully removed by immersing the as-prepared silica nanocomposite in a toluene solution. XRD results demonstrate that the Fe 3 O 4 magnetic nanoparticles still keep spinel structure even heated at low temperature. The surface status of the polystyrene beads and Fe 3 O 4 nanoparticles has an important effect on the formation of the MHSNs. The MHSNs present a superparamagnetism at room temperature by SQUID measurement. The MHSNs have potential applications in biosystem and nanomedicine

  9. Comparison of clinical outcomes after drug-eluting balloon and drug-eluting stent use for in-stent restenosis related acute myocardial infarction: a retrospective study

    Directory of Open Access Journals (Sweden)

    Chih-Yuan Fang

    2018-04-01

    Full Text Available Background Good results of drug-eluting balloon (DEB use are achieved in in-stent restenosis (ISR lesions, small vessel disease, long lesions, and bifurcations. However, few reports exist about DEB use in acute myocardial infarction (AMI with ISR. This study’s aim was to evaluate the efficacy of DEB for AMI with ISR. Methods Between November 2011 and December 2015, 117 consecutive patients experienced AMI including ST-segment elevation MI, and non-ST-segment elevation MI due to ISR, and received percutaneous coronary intervention (PCI. We divided our patients into two groups: (1 PCI with further DEB, and (2 PCI with further drug-eluting stent (DES. Clinical outcomes such as target lesion revascularization, target vessel revascularization, recurrent MI, stroke, cardiovascular mortality, and all-cause mortality were analyzed. Results The patients’ average age was 68.37 ± 11.41 years; 69.2% were male. A total of 75 patients were enrolled in the DEB group, and 42 patients were enrolled in the DES group. The baseline characteristics between the two groups were the same without statistical differences except for gender. Peak levels of cardiac biomarker, pre- and post-PCI cardiac function were similar between two groups. The major adverse cardiac cerebral events rate (34.0% vs. 35.7%; p = 0.688 and cardiovascular mortality rate (11.7% vs. 12.8%; p = 1.000 were similar in both groups. Conclusions DEB is a reasonable strategy for AMI with ISR. Compared with DES, DEB is an alternative strategy which yielded acceptable short-term outcomes and similar 1-year clinical outcomes.

  10. Use of antibiotic beads to salvage infected breast implants.

    Science.gov (United States)

    Sherif, Rami D; Ingargiola, Michael; Sanati-Mehrizy, Paymon; Torina, Philip J; Harmaty, Marco A

    2017-10-01

    When an implant becomes infected, implant salvage is often performed where the implant is removed, capsulectomy is performed, and a new implant is inserted. The patient is discharged with a PICC line and 6-8 weeks of intravenous (IV) antibiotics. This method has variable success and subjects the patient to long-term systemic antibiotics. In the 1960s, the use of antibiotic-impregnated beads for the treatment of chronic osteomyelitis was described. These beads deliver antibiotic directly to the site of the infection, thereby eliminating the complications of systemic IV antibiotics. This study aimed to present a case series illustrating the use of STIMULAN calcium sulfate beads loaded with vancomycin and tobramycin to increase the rate of salvage of the infected implant and forgo IV antibiotics. A retrospective analysis was performed of patients who were treated at Mount Sinai Hospital for implant infection with salvage and antibiotic beads. Twelve patients were identified, 10 of whom had breast cancer. Comorbidities included hypertension, smoking, and immunocompromised status. Infections were noted anywhere from 5 days to 8 years postoperatively. Salvage was successful in 9 out of the 12 infected implants using antibiotic bead therapy without home IV antibiotics. The use of antibiotic beads is promising for salvaging infected breast implants without IV antibiotics. Seventy-five percent of the implants were successfully salvaged. Of the three patients who had unsalvageable implants, one was infected with antibiotic-resistant Rhodococcus that was refractory to bead therapy and one was noncompliant with postoperative instructions. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  11. Two Contrasting Failure Modes of Enteric Coated Beads.

    Science.gov (United States)

    Shi, Galen H; Dong, Xia; Lytle, Michelle; Kemp, Craig A J; Behme, Robert J; Hinds, Jeremy; Xiao, Zhicheng

    2018-04-09

    This study aimed to elucidate the mechanisms and kinetics of coating failure for enteric coated beads exposed to high-humidity conditions at different storage temperatures. Enteric coated beads were placed on high-humidity conditions (75 to 98% relative humidity (RH)) in the temperature range of 5 to 40°C. These stability samples of beads were tested for acid dissolution and water activity and also analyzed with SEM, X-ray CT, and DMA. Exposure of enteric coated beads to high humidity led to increased gastric release of drug which eventually failed the dissolution specification. SEM showed visible cracks on the surface of beads exposed to 5°C/high humidity and fusion of enteric beads into agglomerates at 40°C/high humidity. In a non-destructive time elapse study, X-ray CT demonstrated swelling of microcrystalline cellulose cores, crack initiation, and propagation through the API layer within days under 5°C/98% RH storage conditions and ultimately fracture through the enteric coating. DMA data showed a marked reduction in T g of the enteric coating materials after exposure to humidity. At 5°C/high humidity, the hygroscopic microcrystalline cellulose core absorbed moisture leading to core swelling and consequent fracture through the brittle API and enteric layers. At 40°C (high humidity) which is above the T g of the enteric polymer, enteric coated beads coalesced into agglomerates due to melt flow of the enteric coating. We believe it is the first report on two distinct failure models of enteric coated dosage forms.

  12. Drug-eluting Ti wires with titania nanotube arrays for bone fixation and reduced bone infection

    Science.gov (United States)

    Gulati, Karan; Aw, Moom Sinn; Losic, Dusan

    2011-10-01

    Current bone fixation technology which uses stainless steel wires known as Kirschner wires for fracture fixing often causes infection and reduced skeletal load resulting in implant failure. Creating new wires with drug-eluting properties to locally deliver drugs is an appealing approach to address some of these problems. This study presents the use of titanium [Ti] wires with titania nanotube [TNT] arrays formed with a drug delivery capability to design alternative bone fixation tools for orthopaedic applications. A titania layer with an array of nanotube structures was synthesised on the surface of a Ti wire by electrochemical anodisation and loaded with antibiotic (gentamicin) used as a model of bone anti-bacterial drug. Successful fabrication of TNT structures with pore diameters of approximately 170 nm and length of 70 μm is demonstrated for the first time in the form of wires. The drug release characteristics of TNT-Ti wires were evaluated, showing a two-phase release, with a burst release (37%) and a slow release with zero-order kinetics over 11 days. These results confirmed our system's ability to be applied as a drug-eluting tool for orthopaedic applications. The established biocompatibility of TNT structures, closer modulus of elasticity to natural bones and possible inclusion of desired drugs, proteins or growth factors make this system a promising alternative to replace conventional bone implants to prevent bone infection and to be used for targeted treatment of bone cancer, osteomyelitis and other orthopaedic diseases.

  13. Recent developments in drug eluting devices with tailored interfacial properties.

    Science.gov (United States)

    Sanchez-Rexach, Eva; Meaurio, Emilio; Sarasua, Jose-Ramon

    2017-11-01

    Drug eluting devices have greatly evolved during past years to become fundamental products of great marketing importance in the biomedical field. There is currently a large diversity of highly specialized devices for specific applications, making the development of these devices an exciting field of research. The replacement of the former bare metal devices by devices loaded with drugs allowed the sustained and controlled release of drugs, to achieve the desired local therapeutic concentration of drug. The newer devices have been "engineered" with surfaces containing micro- and nanoscale features in a well-controlled manner, that have shown to significantly affect cellular and subcellular function of various biological systems. For example, the topography can be structured to form an antifouling surface mimicking the defense mechanisms found in nature, like the skin of the shark. In the case of bone implants, well-controlled nanostructured interfaces can promote osteoblast differentiation and matrix production, and enhance short-term and long-term osteointegration. In any case, the goal of current research is to design implants that induce controlled, guided, and rapid healing. This article reviews recent trends in the development of drug eluting devices, as well as recent developments on the micro/nanotechnology scales, and their future challenges. For this purpose medical devices have been divided according to the different systems of the body they are focused to: orthopedic devices, breathing stents, gastrointestinal and urinary systems, devices for cardiovascular diseases, neuronal implants, and wound dressings. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Elution of monomer from different bulk fill dental composite resins.

    Science.gov (United States)

    Cebe, Mehmet Ata; Cebe, Fatma; Cengiz, Mehmet Fatih; Cetin, Ali Rıza; Arpag, Osman Fatih; Ozturk, Bora

    2015-07-01

    The purpose of this study was to evaluate the elution of Bis-GMA, TEGDMA, HEMA, and Bis-EMA monomers from six bulk fill composite resins over four different time periods, using HPLC. Six different composite resin materials were used in the present study: Tetric Evo Ceram Bulk Fill (Ivoclar Vivadent, Amherst, NY), X-tra Fill (VOCO, Cuxhaven, Germany), Sonic Fill (Kerr, Orange, CA, USA), Filtek Bulk Fill (3M ESPE Dental Product, St. Paul, MN), SDR (Dentsply, Konstanz, Germany), EQUIA (GC America INC, Alsip, IL). The samples (4mm thickness, 5mm diameter) were prepared and polymerized for 20s with a light emitted diode unit. After fabrication, each sample was immediately immersed in 75wt% ethanol/water solution used as extraction fluid and stored in the amber colored bottles at room temperature. Ethanol/water samples were taken (0.5mL) at predefined time intervals:10m (T1), 1h (T2), 24h (T3) and 30 days (T4). These samples were analyzed by HPLC. The obtained data were analyzed with one-way ANOVA and Tukey HSD at significance level of pcomposites (pcomposite resins in all time periods and the amount of eluted monomers was increased with time. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  15. Confocal nanoscanning, bead picking (CONA): PickoScreen microscopes for automated and quantitative screening of one-bead one-compound libraries.

    Science.gov (United States)

    Hintersteiner, Martin; Buehler, Christof; Uhl, Volker; Schmied, Mario; Müller, Jürgen; Kottig, Karsten; Auer, Manfred

    2009-01-01

    Solid phase combinatorial chemistry provides fast and cost-effective access to large bead based libraries with compound numbers easily exceeding tens of thousands of compounds. Incubating one-bead one-compound library beads with fluorescently labeled target proteins and identifying and isolating the beads which contain a bound target protein, potentially represents one of the most powerful generic primary high throughput screening formats. On-bead screening (OBS) based on this detection principle can be carried out with limited automation. Often hit bead detection, i.e. recognizing beads with a fluorescently labeled protein bound to the compound on the bead, relies on eye-inspection under a wide-field microscope. Using low resolution detection techniques, the identification of hit beads and their ranking is limited by a low fluorescence signal intensity and varying levels of the library beads' autofluorescence. To exploit the full potential of an OBS process, reliable methods for both automated quantitative detection of hit beads and their subsequent isolation are needed. In a joint collaborative effort with Evotec Technologies (now Perkin-Elmer Cellular Technologies Germany GmbH), we have built two confocal bead scanner and picker platforms PS02 and a high-speed variant PS04 dedicated to automated high resolution OBS. The PS0X instruments combine fully automated confocal large area scanning of a bead monolayer at the bottom of standard MTP plates with semiautomated isolation of individual hit beads via hydraulic-driven picker capillaries. The quantification of fluorescence intensities with high spatial resolution in the equatorial plane of each bead allows for a reliable discrimination between entirely bright autofluorescent beads and real hit beads which exhibit an increased fluorescence signal at the outer few micrometers of the bead. The achieved screening speed of up to 200,000 bead assayed in less than 7 h and the picking time of approximately 1 bead

  16. Some studies on weld bead geometries for laser spot welding process using finite element analysis

    International Nuclear Information System (INIS)

    Siva Shanmugam, N.; Buvanashekaran, G.; Sankaranarayanasamy, K.

    2012-01-01

    Highlights: → In this study, a 2 kW Nd:YAG laser welding system is used to conduct laser spot welding trials. → The size and shape of the laser spot weld is predicted using finite element simulation. → The heat input is assumed to be a three-dimensional conical Gaussian heat source. → The result highlights the effect of beam incident angle on laser spot welds. → The achieved results of numerical simulation are almost identical with a real weldment. -- Abstract: Nd:YAG laser beam welding is a high power density welding process which has the capability to focus the beam to a very small spot diameter of about 0.4 mm. It has favorable characteristics namely, low heat input, narrow heat affected zone and lower distortions, as compared to conventional welding processes. In this study, finite element method (FEM) is applied for predicting the weld bead geometry i.e. bead length (BL), bead width (BW) and depth of penetration (DP) in laser spot welding of AISI 304 stainless steel sheet of thickness 2.5 mm. The input parameters of laser spot welding such as beam power, incident angle of the beam and beam exposure time are varied for conducting experimental trials and numerical simulations. Temperature-dependent thermal properties of AISI 304 stainless steel, the effect of latent heat of fusion, and the convective and radiative aspects of boundary conditions are considered while developing the finite element model. The heat input to the developed model is assumed to be a three-dimensional conical Gaussian heat source. Finite-element simulations of laser spot welding were carried out by using Ansys Parametric Design Language (APDL) available in finite-element code, ANSYS. The results of the numerical analysis provide the shape of the weld beads for different ranges of laser input parameters that are subsequently compared with the results obtained through experimentation and it is found that they are in good agreement.

  17. Using Magnets and Magnetic Beads to Dissect Signaling Pathways Activated by Mechanical Tension Applied to Cells

    Science.gov (United States)

    Marjoram, R.J.; Guilluy, C; Burridge, K.

    2015-01-01

    Cellular tension has implications in normal biology and pathology. Membrane adhesion receptors serve as conduits for mechanotransduction that lead to cellular responses. Ligand-conjugated magnetic beads are a useful tool in the study of how cells sense and respond to tension. Here we detail methods for their use in applying tension to cells and strategies for analyzing the results. We demonstrate the methods by analyzing mechanotransduction through VE-cadherin on endothelial cells using both permanent magnets and magnetic tweezers. PMID:26427549

  18. Preparation of Ca-alginate coated nZVI core shell beads for uranium (VI) removal from aqueous solution

    International Nuclear Information System (INIS)

    Shuhong Hu; Xiaoyan Lin; Yahui Zhang; Meiling Shi

    2017-01-01

    In this study, the core-shell nanoscale zero-valent iron (nZVI)@Alg-Ca beads were synthesized by coaxial electronic injection method for removal of U (VI) from aqueous solution, and characterized by SEM, EDX and XPS. The results showed that the pseudo-second-order models and the Langmuir isotherm model fitted well with the data obtained. The removal mechanism may include both physical adsorption of U (VI) on the surface or inside of core-shell nZVI@Alg-Ca beads and subsequent reduction of U (VI) to U (IV). Therefore, the core-shell nZVI@Alg-Ca beads would have an application prospect in effective removal of U (VI) contamination from aqueous solution. (author)

  19. Fabrication of highly porous keratin sponges by freeze-drying in the presence of calcium alginate beads

    International Nuclear Information System (INIS)

    Hamasaki, Shinichi; Tachibana, Akira; Tada, Daisuke; Yamauchi, Kiyoshi; Tanabe, Toshizumi

    2008-01-01

    Novel fabrication method of highly porous and flexible keratin sponges was developed by combining a particulate-leaching method and a freeze-drying method. Reduced keratin aqueous solution was mixed with dried calcium alginate beads and was lyophilized to give keratin/calcium alginate complex, which was subsequently treated with EDTA solution to leach out calcium alginate beads. The resultant keratin sponge was flexible enough to handle even in dried state because of its quite high porosity (98.9 ± 0.1%), which was brought about by the large and small pores formed by the elimination of calcium alginate beads and water. The sponge supported the attachment and the proliferation of mouse fibroblast cells. Thus, the keratin sponge given by the present fabrication method afforded one alternative as a cell scaffold for tissue engineering

  20. TiO2/beads as a photocatalyst for the degradation of X3B azo dye

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    The feasibility of photocatalytic degradation of X3B azo dye by TiO2/beads photocatalyst was studied. The effects of parameters such as the amount of TiO2/beads, airflow, as well as the concentrations of H2O2, Fe3+, Mg2+ and Na+ on the photocatalytic degradation of X3B azo dye were also studied. The results showed that 25 mg/dm3 X3B azo dye can be photocatalytically degraded completely by 30 min illumination with a 375W medium pressure mercury lamp. Adding a small amount of H2O2 or Fe3+, the efficiencies of photocatalytic degradation of X3B azo dye were increased rapidly. The mechanisms of the reaction and the role of the additives were also investigated. After 120 hours TiO2/beads showed no significant loss of the photocatalytic activity.

  1. EFFECT OF INTERFACIAL ADHESION ON CRYSTALLIZATION AND MECHANICAL PROPERTIES OF POLY (ETHYLENE TEREPHTHALATE)/GLASS BEAD COMPOSITES

    Institute of Scientific and Technical Information of China (English)

    OU Yuchun; YU Zhongzhen; ZHU Jin; LI Ge; ZHU Shanguang

    1996-01-01

    The interfacial adhesion between poly (ethylene terephthalate) (PET) and glass bead was investigated by scanning electron microscope and parallel-plate rheometer. Effect of interfacial adhesion on the crystallization and mechanical properties of PET/glass bead composites was also studied by differential scanning calorimeter and mechanical testers.The results obtained indicate that the glass bead has a heterogeneous nucleation effect on the PET crystallization. Although better interfacial adhesion is advantageous to the increase of the tensile strength of the composite, yet it is unfavorable to the crystallization of PET. It should be pointed out that the crystallization rate of filled PET is always higher than that of pure PET, regardless of the state of interfacial adhesion.

  2. New Detection Modality for Label-Free Quantification of DNA in Biological Samples via Superparamagnetic Bead Aggregation

    Science.gov (United States)

    Leslie, Daniel C.; Li, Jingyi; Strachan, Briony C.; Begley, Matthew R.; Finkler, David; Bazydlo, Lindsay L.; Barker, N. Scott; Haverstick, Doris; Utz, Marcel; Landers, James P.

    2012-01-01

    Combining DNA and superparamagnetic beads in a rotating magnetic field produces multiparticle aggregates that are visually striking, and enables label-free optical detection and quantification of DNA at levels in the picogram per microliter range. DNA in biological samples can be quantified directly by simple analysis of optical images of microfluidic wells placed on a magnetic stirrer without DNA purification. Aggregation results from DNA/bead interactions driven either by the presence of a chaotrope (a nonspecific trigger for aggregation) or by hybridization with oligonucleotides on functionalized beads (sequence-specific). This paper demonstrates quantification of DNA with sensitivity comparable to that of the best currently available fluorometric assays. The robustness and sensitivity of the method enable a wide range of applications, illustrated here by counting eukaryotic cells. Using widely available and inexpensive benchtop hardware, the approach provides a highly accessible low-tech microscale alternative to more expensive DNA detection and cell counting techniques. PMID:22423674

  3. The role of drug-eluting balloons alone or in combination with drug-eluting stents in the treatment of de novo diffuse coronary disease.

    Science.gov (United States)

    Costopoulos, Charis; Latib, Azeem; Naganuma, Toru; Sticchi, Alessandro; Figini, Filippo; Basavarajaiah, Sandeep; Carlino, Mauro; Chieffo, Alaide; Montorfano, Matteo; Naim, Charbel; Kawaguchi, Masanori; Giannini, Francesco; Colombo, Antonio

    2013-11-01

    This study sought to investigate the role of drug-eluting balloons (DEB) alone or in combination with drug-eluting stents (DES) in the treatment of diffuse de novo coronary artery disease (CAD) (>25 mm). The use of DEB in diffuse CAD, either alone or in combination with DES, offers an alternative to stenting alone. Data regarding DEB in this context are limited. We retrospectively evaluated all patients treated with DEB for diffuse CAD between June 2009 and October 2012. Endpoints analyzed were major adverse cardiac events, defined as all-cause death, myocardial infarction, and target vessel revascularization (TVR), as well as TVR and target lesion revascularization separately. Results were compared with those obtained from a cohort of patients with similar characteristics treated with DES alone. A total of 69 patients (93 lesions) were treated with DEB ± DES, and 93 patients with DES alone (93 lesions). A high proportion of patients were diabetic (46.4% vs. 44.1%, p = 0.77). Of the DEB-treated lesions, 56.0% were treated with DEB alone, 7.4% with DEB and DES as bail out, and 36.6% with DES and DEB as part of a hybrid approach for very long disease. Outcome rates with DEB ± DES were comparable to those with DES alone at 2-year follow-up (major adverse cardiac events = 20.8% vs. 22.7%, p = 0.74; TVR = 14.8% vs. 11.5%, p = 0.44; target lesion revascularization = 9.6% vs. 9.3%, p = 0.84). DEB may have a role in the treatment of diffuse de novo CAD, either alone in smaller vessels or in combination with DES in very long disease. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  4. Late lumen loss and intima hyperplasia after sirolimus-eluting and zotarolimus-eluting stent implantation in diabetic patients: the diabetes and drug-eluting stent (DiabeDES III) angiography and intravascular ultrasound trial

    DEFF Research Database (Denmark)

    Jensen, Lisette Okkels; Mæng, Michael; Thayssen, Per

    2011-01-01

    Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent implantation due to neointimal hyperplasia (NIH). The aim of this study was to use quantitative coronary angiography (QCA) and volumetric intravascular ultrasound (IVUS) to evaluate the effects...... of the sirolimus-eluting Cypher® stent (SES) and the zotarolimus-eluting Endeavor® stent (ZES) on angiographic late lumen loss and intima hyperplasia in diabetic patients....

  5. Fluorescent detection of C-reactive protein using polyamide beads

    Science.gov (United States)

    Jagadeesh, Shreesha; Chen, Lu; Aitchison, Stewart

    2016-03-01

    Bacterial infection causes Sepsis which is one of the leading cause of mortality in hospitals. This infection can be quantified from blood plasma using C - reactive protein (CRP). A quick diagnosis at the patient's location through Point-of- Care (POC) testing could give doctors the confidence to prescribe antibiotics. In this paper, the development and testing of a bead-based procedure for CRP quantification is described. The size of the beads enable them to be trapped in wells without the need for magnetic methods of immobilization. Large (1.5 mm diameter) Polyamide nylon beads were used as the substrate for capturing CRP from pure analyte samples. The beads captured CRP either directly through adsorption or indirectly by having specific capture antibodies on their surface. Both methods used fluorescent imaging techniques to quantify the protein. The amount of CRP needed to give a sufficient fluorescent signal through direct capture method was found suitable for identifying bacterial causes of infection. Similarly, viral infections could be quantified by the more sensitive indirect capture method. This bead-based assay can be potentially integrated as a disposable cartridge in a POC device due to its passive nature and the small quantities needed.

  6. Size distribution of DNA molecules recovered from non-denaturing filter elution

    International Nuclear Information System (INIS)

    Bloecher, D.; Iliakis, G.

    1991-01-01

    DNA fragments removed from the filter during non-denaturing filter elution were collected and loaded on top of neutral sucrose gradients. Their size distribution was determined by low-speed centrifugation in neutral sucrose gradients. The average size of eluted DNA was found to be approximately 110 S; the average size of DNA collected after short elution times was found to be slightly larger than after long elution times. It is concluded that the size of eluted DNA fragments is not correlated with elution rate, and it is proposed that shear forces generated at the filter pores cause degradation of the DNA. Comparison of sedimentation profiles of carefully prepared cellular DNA before and after elution revealed that generated shear forces during elution break down DNA to an extent equivalent to around 20 000 DNA double-strand breaks (dsb) per G 1 cell. The size of DNA fragments decreased with increasing radiation dose; five times more dsb were found than expected after exposure to radiation alone. It is proposed that excess of dsb may derive from the transformation of other radiation-induced lesions to dsb under the action of shear forces generated during elution. (author)

  7. Measurement of M. luteus endonuclease-sensitive lesions by alkaline elution

    Energy Technology Data Exchange (ETDEWEB)

    Fornace, Jr, A J [National Cancer Inst., Bethesda, MD (USA). Lab. for Experimental Pathology

    1982-01-01

    The UV-endonuclease approach to detect DNA damage has been combined with the alkaline elution technique with a resultant marked increase in sensitivity compared to the conventional method using alkaline sedimentation. DNA from UV-irradiated cells was digested on an inert filter with an extract from Micrococcus luteus and then analyzed by alkaline elution. Endonuclease-sensitive sites (endo-sites) were measured after doses of 0.08-0.7 Jm/sup -2/ of UV-radiation. An estimate of endo-site production with UV radiation, 0.27 endo-sites/10/sup 8/ daltons of DNA/0.1 Jm/sup -2/, was similar to that usually seen at higher doses by others. With repair incubation, approx. 50% of the endo-sites were removed in 4 h by normal human fibroblasts after 0.2 or 0.4 Jm/sup -2/, no appreciable repair was seen in xeroderma pigmentosum fibroblasts from complementation group A after 24 h of repair incubation. No photoreaction of UV damage due to 0.4 Jm/sup -2/ was detected in normal human fibroblasts.

  8. Measurement of M. luteus endonuclease-sensitive lesions by alkaline elution

    International Nuclear Information System (INIS)

    Fornace, A.J. Jr.

    1982-01-01

    The UV-endonuclease approach to detect DNA damage has been combined with the alkaline elution technique with a resultant marked increase in sensitivity compared to the conventional method using alkaline sedimentation. DNA from UV-irradiated cells was digested on an inert filter with an extract from Micrococcus luteus and then analyzed by alkaline elution. Endonuclease-sensitive sites (endo-sites) were measured after doses of 0.08-0.7 Jm -2 of UV-radiation. An estimate of endo-site production with UV radiation, 0.27 endo-sites/10 8 daltons of DNA/0.1 Jm -2 , was similar to that usually seen at higher doses by others. With repair incubation, approx. 50% of the endo-sites were removed in 4 h by normal human fibroblasts after 0.2 or 0.4 Jm -2 , no appreciable repair was seen in xeroderma pigmentosum fibroblasts from complementation group A after 24 h of repair incubation. No photoreaction of UV damage due to 0.4 Jm -2 was detected in normal human fibroblasts. (orig./AJ)

  9. Adsorption of Cd(II) Metal Ion on Adsorbent beads from Biomass Saccharomycess cereviceae - Chitosan

    Science.gov (United States)

    Hasri; Mudasir

    2018-01-01

    The adsorbent beads that was preparation from Saccharomycess cereviceae culture strain FN CC 3012 and shrimp shells waste and its application for adsorption of Cd (II) metal ion has been studied. The study start with combination of Saccharomycess cereviceae biomass to chitosan (Sc-Chi), contact time, pH of solution and initial concentration of cations. Total Cd(II) metal ion adsorbed was calculated from the difference of metal ion concentration before and after adsorption by AAS. The results showed that optimum condition for adsorption of Cd(II) ions by Sc-Chi beads was achieved with solution pH of 4, contact time of 60 minutes and initial concentration adsorption 100mg/L. The hydroxyl (-OH) and amino (-NH2) functional groups were believed to be responsible for the adsorption of Cd(II) ions.

  10. Study on Surface Modification of Glass Bead by a Block Copolymer Coupling Agent

    Institute of Scientific and Technical Information of China (English)

    LI Yin; ZHANG Bing; ZHOU Xiao-dong

    2008-01-01

    A tri-block copolymer coupling agent polystyrene biock-poly(n-butyl-acrylate)-block-poly(r-methacryloxypro pylt rimethoxysilane)(PS-b-PnBA-b-PMPS)was synthesized by atom transfer radical polymerization(ATRP),and its molecular structure was characterized by fourier-transform infrared spectra,hydrogen nuclear magnetic resonance and gel permeation chromatography.The glass bead was treated with the block copolymer coupling agent,and then studied by transmission electron microscopy.The result showed that strong interaction was formed between the block copolymer coupling agent and the surface of glass bead,and then the block of poly(n-butylacrylate)formed a layer of film on the surface.

  11. Effect of patterned micro-magnets on superparamagnetic beads in microchannels

    International Nuclear Information System (INIS)

    Guo, S S; Deng, Y L; Zhao, L B; Zhao, X-Z; Chan, H L W

    2008-01-01

    The trapping response of patterned micro-magnets (PMMs) was studied based on the parameters affecting superparamagnetic beads in microfluidic channels. Using replica moulding and electroplating technologies, the PMMs were fabricated on the microchannel bottom, which generated sufficient magnetic forces to bias the moments of magnetic particles in a flowing stream. A simplified physical principle was used to analyse the relative velocity of the magnetic particle in the confined space of a microchannel. The results revealed that the magnetic force contributed to the fluidic flow rate as well as to the hydrodynamic drag force. The relative velocity of magnetic particles was dependent on the frequency under an external magnetic field driven by an alternate current (ac) source. It showed that the magnetic gradient induced hysteresis characteristics of the transmission spectrum, associated with the interaction of superparamagnetic beads and magnetic field

  12. A micro-pillar array to trap magnetic beads in microfluidic systems

    KAUST Repository

    Gooneratne, Chinthaka Pasan

    2012-12-01

    A micro-pillar array (MPA) is proposed in this paper to trap and separate magnetic beads (MBs) in microfluidic systems. MBs are used in many biomedical applications due to being compatible in dimension to biomolecules, the large surface area available to attach biomolecules, and the fact that they can be controlled by a magnetic field. Trapping and separating these labeled biomolecules is an important step toward achieving reliable and accurate quantification for disease diagnostics. Nickel Iron (Ni50Fe 50) micro-pillars were fabricated on a Silicon (Si) substrate by standard microfabrication techniques. Experimental results showed that MBs could be trapped on the MPA at the single bead level and separated from other non-target particles. This principle can easily be extended to trap and separate target biomolecules in heterogeneous biological samples. © 2012 IEEE.

  13. Improving the Stability of Astaxanthin by Microencapsulation in Calcium Alginate Beads.

    Directory of Open Access Journals (Sweden)

    Shen-Fu Lin

    Full Text Available There has been considerable interest in the biological functions of astaxanthin and its potential applications in the nutraceutical, cosmetics, food, and feed industries in recent years. However, the unstable structure of astaxanthin considerably limits its application. Therefore, this study reports the encapsulation of astaxanthin in calcium alginate beads using the extrusion method to improve its stability. This study also evaluates the stability of the encapsulated astaxanthin under different storage conditions. The evaluation of astaxanthin stability under various environmental factors reveals that temperature is the most influential environmental factor in astaxanthin degradation. Stability analysis shows that, regardless of the formulation used, the content of astaxanthin encapsulated in alginate beads remains above 90% of the original amount after 21 days of storage at 25°C. These results suggest that the proposed technique is a promising way to enhance the stability of other sensitive compounds.

  14. RELIC: a novel dye-bias correction method for Illumina Methylation BeadChip.

    Science.gov (United States)

    Xu, Zongli; Langie, Sabine A S; De Boever, Patrick; Taylor, Jack A; Niu, Liang

    2017-01-03

    The Illumina Infinium HumanMethylation450 BeadChip and its successor, Infinium MethylationEPIC BeadChip, have been extensively utilized in epigenome-wide association studies. Both arrays use two fluorescent dyes (Cy3-green/Cy5-red) to measure methylation level at CpG sites. However, performance difference between dyes can result in biased estimates of methylation levels. Here we describe a novel method, called REgression on Logarithm of Internal Control probes (RELIC) to correct for dye bias on whole array by utilizing the intensity values of paired internal control probes that monitor the two color channels. We evaluate the method in several datasets against other widely used dye-bias correction methods. Results on data quality improvement showed that RELIC correction statistically significantly outperforms alternative dye-bias correction methods. We incorporated the method into the R package ENmix, which is freely available from the Bioconductor website ( https://www.bioconductor.org/packages/release/bioc/html/ENmix.html ). RELIC is an efficient and robust method to correct for dye-bias in Illumina Methylation BeadChip data. It outperforms other alternative methods and conveniently implemented in R package ENmix to facilitate DNA methylation studies.

  15. Bead-based screening in chemical biology and drug discovery

    DEFF Research Database (Denmark)

    Komnatnyy, Vitaly V.; Nielsen, Thomas Eiland; Qvortrup, Katrine

    2018-01-01

    libraries for early drug discovery. Among the various library forms, the one-bead-one-compound (OBOC) library, where each bead carries many copies of a single compound, holds the greatest potential for the rapid identification of novel hits against emerging drug targets. However, this potential has not yet...... been fully realized due to a number of technical obstacles. In this feature article, we review the progress that has been made towards bead-based library screening and applications to the discovery of bioactive compounds. We identify the key challenges of this approach and highlight key steps needed......High-throughput screening is an important component of the drug discovery process. The screening of libraries containing hundreds of thousands of compounds requires assays amanable to miniaturisation and automization. Combinatorial chemistry holds a unique promise to deliver structural diverse...

  16. Development of multifunctional chitosan beads for fluoride removal

    Energy Technology Data Exchange (ETDEWEB)

    Viswanathan, Natrayasamy [Department of Chemistry, Gandhigram Rural University, Gandhigram 624 302, Tamilnadu (India); Sairam Sundaram, C. [Department of Science and Humanities, Karaikal Polytechnic College, Karaikal 609 609, Puducherry (India); Meenakshi, S., E-mail: drs_meena@rediffmail.com [Department of Chemistry, Gandhigram Rural University, Gandhigram 624 302, Tamilnadu (India)

    2009-08-15

    Chitosan beads (CB) which have negligible defluoridation capacity (DC) have been chemically modified by introducing multifunctional groups, viz., NH{sub 3}{sup +} and COOH groups by means of protonation and carboxylation in order to utilize both amine and hydroxyl groups for fluoride removal. The protonated cum carboxylated chitosan beads (PCCB) showed a maximum DC of 1800 mg F{sup -}/kg whereas raw chitosan beads displayed only 52 mg F{sup -}/kg. Sorption process was found to be independent of pH and slightly influenced in the presence of other common anions. The fluoride sorption on modified forms was reasonably explained by Freundlich and Langmuir isotherms. The sorbents were characterised by FTIR and SEM with EDAX analysis. The sorption process follows pseudo-second-order and intraparticle diffusion kinetic models. The suitability of PCCB has been tested with field sample collected from a nearby fluoride endemic area.

  17. A vortex-bowl disk atomizer system for the production of alginate beads in a 1500-liter fermentor.

    Science.gov (United States)

    Champagne, C P; Blahuta, N; Brion, F; Gagnon, C

    2000-06-20

    Using a model system, a concept for the immobilization of microbial cultures within alginate beads directly in a 1500-L fermentor with a height to diameter ratio of 1.85 is described. The system is comprised of a 60-cm diameter bowl fixed to the top of an agitation shaft, where calcium-ion-rich media is continuously recirculated from the bulk solution to the bowl. The rotation of the shaft and bowl creates a climbing film (vortex) of solution. An atomizing disk centrally recessed within the bowl sprays an alginate solution into the climbing film where the droplets harden into beads. The effect of heat treatment on the alginate solution on resulting bead properties was examined. The sterilization operation did not appear to have a major effect on the alginate bead mechanical properties of firmness and elasticity which was much more a function of alginate concentration. Beads of various sizes were produced by the unit. The system was characterized by the dimensionless numbers Reomega = (omega x rho x D(2))/mu and ReQ = (Q x rho)/(mu x D). At Reomega and ReQ values less than 500 and 0.15, respectively, the mechanism was direct drop. Parent droplets followed by satellite droplets were observed. When either the flow rate or speed was increased, filaments formed predominantly, which was unwanted in this system because filament breakdown into smaller droplets does not occur due to the proximity of the disk to the climbing film in the bowl. This system could be applied to the immobilization of microorganisms, as well as plant or animal cell cultures, and for other sizes or fermentors. The overflow from the bowl carries the gellified beads into the bulk solution where immobilized cells could act upon the fermentation media. Copyright 2000 John Wiley & Sons, Inc.

  18. Simultaneous detection and removal of radioisotopes with modified alginate beads containing an azo-based probe using RGB coordinates

    International Nuclear Information System (INIS)

    Jo, Ara; Jang, Geunseok; Namgung, Ho; Kim, Choongho; Kim, Daigeun; Kim, Yujun; Kim, Jongho; Lee, Taek Seung

    2015-01-01

    Highlights: • Modified alginate with azo-based probe (ABO) was synthesized by a reaction between sodium alginate and azo-based probe (BO2). • BO2 was found to be a good probe molecule for radioisotopes using colorimetric analysis. • Detection of Co 2+ and Sr 2+ was mainly carried out via interaction between BO2 and metal ions. • Simultaneous removal of radioisotopes was assessed by the ion-exchange of carboxylate groups in sodium alginate. • The alginate beads with dual functions of detection and removal of metal ions are successfully accomplished. - Abstract: We prepared alginate beads that were modified with an azo-based probe molecule to monitor simultaneously the removal (by alginate) and probing (by the azo-probe molecule) of radioisotopes such as cobalt, strontium, and cesium ions. As an azo-probe molecule, Basic Orange 2 (BO2) was immobilized to the alginate bead. The BO2 in aqueous solution exhibited a slight red shift in absorption with a change in color from orange to dark orange upon addition of cobalt and strontium ions. In contrast, the color of BO2 did not change upon exposure to cesium ions. Thus, the covalently embedded BO2 in alginate beads could adsorb cobalt and strontium ions resulting in recognizable color change of the beads, which was induced by the formation of a complex between BO2 and metal ions. The color changes of the beads in the presence of metal ions were determined quantitatively using RGB color coordinate values. In addition to effectively removing metal ions, the colorimetric coordinate method provides a convenient and simple sensing technique for naked-eye metal ion detection.

  19. Determinants of protein elution rates from preparative ion-exchange adsorbents.

    Science.gov (United States)

    Angelo, James M; Lenhoff, Abraham M

    2016-04-01

    The rate processes involved in elution in preparative chromatography can affect both peak resolution and hence selectivity as well as practical factors such as facility fit. These processes depend on the physical structure of the adsorbent particles, the amount of bound solute, the solution conditions for operation or some combination of these factors. Ion-exchange adsorbents modified with covalently attached or grafted polymer layers have become widely used in preparative chromatography. Their often easily accessible microstructures offer substantial binding capacities for biomolecules, but elution has sometimes been observed to be undesirably slow. In order to determine which physicochemical phenomena control elution behavior, commercially available cellulosic, dextran-grafted and unmodified agarose materials were characterized here by their elution profiles at various conditions, including different degrees of loading. Elution data were analyzed under the assumption of purely diffusion-limited control, including the role of pore structure properties such as porosity and tortuosity. In general, effective elution rates decreased with the reduction of accessible pore volume, but differences among different proteins indicated the roles of additional factors. Additional measurements and analysis, including the use of confocal laser scanning microscopy to observe elution within single chromatographic particles, indicated the importance of protein association within the particle during elution. The use of protein stabilizing agents was explored in systems presenting atypical elution behavior, and l-arginine and disaccharide excipients were shown to alleviate the effects for one protein, lysozyme, in the presence of sodium chloride. Incorporation of these excipients into eluent buffer gave rise to faster elution and significantly lower pool volumes in elution from polymer-modified adsorbents. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Resolution of co-eluting compounds of Cannabis Sativa in comprehensive two-dimensional gas chromatography/mass spectrometry detection with Multivariate Curve Resolution-Alternating Least Squares.

    Science.gov (United States)

    Omar, Jone; Olivares, Maitane; Amigo, José Manuel; Etxebarria, Nestor

    2014-04-01

    Comprehensive Two Dimensional Gas Chromatography - Mass Spectrometry (GC × GC/qMS) analysis of Cannabis sativa extracts shows a high complexity due to the large variety of terpenes and cannabinoids and to the fact that the complete resolution of the peaks is not straightforwardly achieved. In order to support the resolution of the co-eluted peaks in the sesquiterpene and the cannabinoid chromatographic region the combination of Multivariate Curve Resolution and Alternating Least Squares algorithms was satisfactorily applied. As a result, four co-eluting areas were totally resolved in the sesquiterpene region and one in the cannabinoid region in different samples of Cannabis sativa. The comparison of the mass spectral profiles obtained for each resolved peak with theoretical mass spectra allowed the identification of some of the co-eluted peaks. Finally, the classification of the studied samples was achieved based on the relative concentrations of the resolved peaks. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Development of DNA elution method to detect irradiated foodstuff

    International Nuclear Information System (INIS)

    Copin, M.P.; Bourgeois, C.M.

    1991-01-01

    The aim of the work is to develop a reliable method to detect whether a fresh and frozen foodstuff has been irradiated. The molecule of DNA is one of the targets of ionizing radiation. The induction of three major classes of lesion have been shown. Double strand breaks, single strand breaks and base damage. Among the different techniques used to observe and quantify the strand breaks, techniques of elution are very interesting. The method proposed consisted of a filtration of the DNA at the atmospheric pressure and in non denaturing conditions. The amount of DNA retained on the filter is measured after being suitably labelled by microfluorometry. A difference in the amount of DNA retained on a filter of 2 μm from a lysed muscular tissue sample between a frozen Norway lobster which has been irradiated and one which has not, is observed. 7 refs