WorldWideScience

Sample records for elevation impairs implantation

  1. Amorphisation during elevated temperature implantation

    International Nuclear Information System (INIS)

    Carter, G.; Nobes, M.J.; Elliman, R.G.

    1994-01-01

    Transition state theory is employed to predict the rates of amorphous zone recrystallization by direct thermal and radiation mediated thermal annealing processes. These rates are functions of zone radius and are employed to describe the competition between amorphous zone generation and annealing during elevated temperature heavy ion implantation of, particularly, Si and the accumulation of amorphousness with increasing ion fluence. This analysis predicts a change from monotonic to sigmoidal to biexponential accumulation functions with increasing annealing rate or substrate temperature in agreement with experiments. A logarithmic dependence of ion flux density upon substrate temperature for the achievement of defined fractional amorphisation is predicted and is also in agreement with the experiment. (author)

  2. Troponin T elevation after permanent pacemaker implantation.

    Science.gov (United States)

    Chen, Xueying; Yu, Ziqing; Bai, Jin; Hu, Shulan; Wang, Wei; Qin, Shengmei; Wang, Jingfeng; Sun, Zhe; Su, Yangang; Ge, Junbo

    2017-08-01

    The objective of the study is to study the incidence, significance, and factors associated with cardiac troponin T (CTNT) elevation after pacemaker implantation. Three hundred seventy-four patients (104 single-chamber pacemakers or ICD, 243 dual-chamber pacemakers, and 27 cardiac resynchronization therapy/cardiac resynchronization therapy defibrillator) who had normal levels of CTNT at baseline and underwent implantation of a permanent pacemaker system were included in this study. Serum levels of CTNT were measured at baseline, 6 and 24 h after the implantation procedure. The median of CTNT levels increased from 0.012 ng/mL at baseline to 0.032 and 0.019 ng/mL at 6 and 24 h after the procedure, respectively (all p 0.09 ng/mL). After 1-year follow-up, the incidence of complications including dislodgement of the lead, pocket infection, pneumothorax, hemothorax, and vein thrombus and cardiac outcomes including hospitalization of heart failure, coronary artery disease, arrhythmia, and cardiovascular mortality was not significantly different between the normal and elevated CTNT groups at 6 h after the procedure. By logistic regression analysis, gender, N-terminal pro-B type natriuretic peptide (NT-pro-BNP) at baseline, left ventricular ejection fractions (LVEF), estimated glomerular filtration rate (eGFR), and fluoroscopy time were independently associated with CTNT elevation after adjusted for age, pacemaker types, right ventricle lead location (RVA or RVOT), heart function, and left ventricular end systolic dimension. Pacemaker implantation was found to be accompanied with CTNT elevation in 55.6% of the patients at 6 h after the procedure, and its kinetics were fast, which might not be related to the complications and adverse cardiac outcomes within 1 year of follow-up. Moreover, gender, NT-pro-BNP at baseline, LVEF, eGFR, and fluoroscopy time were found to be independent predictors of CTNT elevation.

  3. Elevated Lipoprotein(A Impairs Platelet Radiolabeling Yield

    Directory of Open Access Journals (Sweden)

    Susanne Granegger

    2015-02-01

    Full Text Available Objectives: Platelet radiolabeling in clinical routine usually results in labeling efficiencies (LE above 80%. A variety of risk factors and clinical conditions are known to impair platelet labeling yield, among them elevated triglycerides and low-density lipoproteins. The potential influence of lipoprotein(a (Lp(a, an atherogenic lipoprotein particle containing a kringle subunit, which is widely found in the proteins of fibrinolysis pathway, has never been studied. Normal Lp(a levels range below 30 mg/ dl. The exact prevalence of elevated Lp(a is unknown, most likely ranging below 10%. Even more rare is an isolated elevation despite an otherwise normal lipoprotein profile. Methods: We examined the role of isolated elevated Lp(a (> 50 mg/dl, ranging up to 440 mg/dl compared to patients with normal lipid profile. Platelets were radiolabeled with in-111-oxine at 37 °C for 5 minutes using ISORBE-consensus methodology. Results: The findings indicate that already at levels below 100 mg/dl Lp(a decreases LE. LE assessment after cross-incubation of hyper-Lp(a platelets with normal Lp(a plasma and vice versa reveals that platelets rather than the plasmatic environment are responsible for the deterioration of labeling yield. This behavior already has been reported for elevated low-density lipoproteins. Apparently, the quantitative influence of LDL and Lp(a/mg is comparable. Plotting the sum of LDL and Lp(a versus LE reveals a clear significant negative correlation. Conclusion: As extremely elevated Lp(a, particularly above 150 mg/dl, may significantly impair labeling results. We therefore recommend to include extremely elevated Lp(a into the list of parameters, which should be known before performing radiolabeling of human platelets.

  4. Effects of elevated ambient temperature on embryo implantation in rats

    African Journals Online (AJOL)

    Yomi

    2012-03-22

    Mar 22, 2012 ... ambient temperature leads to a delayed implantation and reduced number of implantation sites in. Sprague ... rates decrease after exposure to stress. One of the ..... implantation initiation time, support the previous findings.

  5. Predicting impaired extinction of traumatic memory and elevated startle.

    Directory of Open Access Journals (Sweden)

    Rebecca Nalloor

    Full Text Available Emotionally traumatic experiences can lead to debilitating anxiety disorders, such as phobias and Post-Traumatic Stress Disorder (PTSD. Exposure to such experiences, however, is not sufficient to induce pathology, as only up to one quarter of people exposed to such events develop PTSD. These statistics, combined with findings that smaller hippocampal size prior to the trauma is associated with higher risk of developing PTSD, suggest that there are pre-disposing factors for such pathology. Because prospective studies in humans are limited and costly, investigating such pre-dispositions, and thus advancing understanding of the genesis of such pathologies, requires the use of animal models where predispositions are identified before the emotional trauma. Most existing animal models are retrospective: they classify subjects as those with or without a PTSD-like phenotype long after experiencing a traumatic event. Attempts to create prospective animal models have been largely unsuccessful.Here we report that individual predispositions to a PTSD-like phenotype, consisting of impaired rate and magnitude of extinction of an emotionally traumatic event coupled with long-lasting elevation of acoustic startle responses, can be revealed following exposure to a mild stressor, but before experiencing emotional trauma. We compare, in rats, the utility of several classification criteria and report that a combination of criteria based on acoustic startle responses and behavior in an anxiogenic environment is a reliable predictor of a PTSD-like phenotype.There are individual predispositions to developing impaired extinction and elevated acoustic startle that can be identified after exposure to a mildly stressful event, which by itself does not induce such a behavioral phenotype. The model presented here is a valuable tool for studying the etiology and pathophysiology of anxiety disorders and provides a platform for testing behavioral and pharmacological

  6. Maxillary Sinus Membrane Elevation With Simultaneous Installation of Implants Without the Use of a Graft Material

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Schou, Søren

    2017-01-01

    OBJECTIVE: To compare implant treatment outcome after maxillary sinus membrane elevation with simultaneous installation of implants with or without the use of graft material applying the lateral window technique. MATERIALS AND METHODS: MEDLINE/PubMed, Cochrane Library, and Embase search in combin...

  7. Delayed breast reconstruction with implants after invasive breast cancer does not impair prognosis

    DEFF Research Database (Denmark)

    Holmich, L.R.; During, M.; Henriksen, T.F.

    2008-01-01

    We investigated if delayed breast implant reconstruction after breast cancer impairs prognosis. Using data from the Danish Breast Cancer Cooperative Group register, we identified all women......We investigated if delayed breast implant reconstruction after breast cancer impairs prognosis. Using data from the Danish Breast Cancer Cooperative Group register, we identified all women...

  8. Soaking morselized allograft in bisphosphonate can impair implant fixation

    DEFF Research Database (Denmark)

    Jakobsen, Thomas; Baas, Jørgen; Bechtold, Joan E

    2007-01-01

    biomechanical implant fixation and graft incorporation. In 10 dogs, a pair of titanium implants surrounded by a 2.5-mm gap was inserted into the proximal part of each humerus during two separate surgeries to allow two observation periods. The gap was filled with impacted, morselized allograft soaked in either...... of implants was observed for 12 weeks and the second pair for 4 weeks. Implants were evaluated by histomorphometry and biomechanical pushout test. We found substantially decreased biomechanical implant fixation for all implants surrounded by impacted, morselized allograft that had been soaked in alendronate...

  9. Elevations in core and muscle temperature impairs repeated sprint performance

    DEFF Research Database (Denmark)

    Drust, B.; Rasmussen, P.; Mohr, Magni

    2005-01-01

    on a cycle ergometer in normal (approximately 20 degrees C, control) and hot (40 degrees C, hyperthermia) environments. RESULTS: Completion of the intermittent protocol in the heat elevated core and muscle temperatures (39.5 +/- 0.2 degrees C; 40.2 +/- 0.4 degrees C), heart rate (178 +/- 11 beats min(-1...... metabolic fatigue agents and we, therefore, suggest that it may relate to the influence of high core temperature on the function of the central nervous system.......)), rating of perceived exertion (RPE) (18 +/- 1) and noradrenaline (38.9 +/- 13.2 micromol l(-1)) (all P

  10. Psycholinguistic abilities in cochlear implant and hearing impaired children

    OpenAIRE

    Hassan, Hatem Ezzeldin; Eldin, Sally Taher Kheir; Al Kasaby, Rasha Mohamed

    2014-01-01

    Background: Many congenitally sensorineural hearing loss (SNHL) children and cochlear implant (CI) recipients develop near-normal language skills. However, there is a wide variation in individual outcomes following cochlear implantation, or using hearing aids. Some CI recipients or Hearing aids users never develop useable speech and oral language skills. The causes of this enormous variation in outcomes are only partly understood at the present time. So, the aim of this study was to assess th...

  11. Elevated Temperature and CO2 Stimulate Late-Season Photosynthesis But Impair Cold Hardening in Pine.

    Science.gov (United States)

    Chang, Christine Y; Fréchette, Emmanuelle; Unda, Faride; Mansfield, Shawn D; Ensminger, Ingo

    2016-10-01

    Rising global temperature and CO 2 levels may sustain late-season net photosynthesis of evergreen conifers but could also impair the development of cold hardiness. Our study investigated how elevated temperature, and the combination of elevated temperature with elevated CO 2 , affected photosynthetic rates, leaf carbohydrates, freezing tolerance, and proteins involved in photosynthesis and cold hardening in Eastern white pine (Pinus strobus). We designed an experiment where control seedlings were acclimated to long photoperiod (day/night 14/10 h), warm temperature (22°C/15°C), and either ambient (400 μL L -1 ) or elevated (800 μmol mol -1 ) CO 2 , and then shifted seedlings to growth conditions with short photoperiod (8/16 h) and low temperature/ambient CO 2 (LTAC), elevated temperature/ambient CO 2 (ETAC), or elevated temperature/elevated CO 2 (ETEC). Exposure to LTAC induced down-regulation of photosynthesis, development of sustained nonphotochemical quenching, accumulation of soluble carbohydrates, expression of a 16-kD dehydrin absent under long photoperiod, and increased freezing tolerance. In ETAC seedlings, photosynthesis was not down-regulated, while accumulation of soluble carbohydrates, dehydrin expression, and freezing tolerance were impaired. ETEC seedlings revealed increased photosynthesis and improved water use efficiency but impaired dehydrin expression and freezing tolerance similar to ETAC seedlings. Sixteen-kilodalton dehydrin expression strongly correlated with increases in freezing tolerance, suggesting its involvement in the development of cold hardiness in P. strobus Our findings suggest that exposure to elevated temperature and CO 2 during autumn can delay down-regulation of photosynthesis and stimulate late-season net photosynthesis in P. strobus seedlings. However, this comes at the cost of impaired freezing tolerance. Elevated temperature and CO 2 also impaired freezing tolerance. However, unless the frequency and timing of extreme low

  12. Precise Estimation of Cellular Radio Electromagnetic Field in Elevators and EMI Impact on Implantable Cardiac Pacemakers

    Science.gov (United States)

    Harris, Louis-Ray; Hikage, Takashi; Nojima, Toshio

    The purpose of this paper is to investigate the possible impact of cellular phones' signals on implantable cardiac pacemakers in elevators. This is achieved by carrying out precise numerical simulations based on the Finite-Difference-Time-Domain method to examine the electromagnetic fields in elevator models. In order to examine the realistic and complicated situations where humans are present in the elevator, we apply the realistic homogeneous human phantom and cellular radios operating in the frequency bands 800MHz, 1.5GHz and 2GHz. These computed results of field strength inside the elevator are compared with a certain reference level determined from the experimentally obtained maximum interference distance of implantable cardiac pacemakers. This enables us to carry out a quantitative evaluation of the EMI risk to pacemakers by cellular radio transmission. The results show that for the case when up to 5 mobile radio users are present in the elevator model used, there is no likelihood of pacemaker malfunction for the frequency bands 800MHz, 1.5GHz and 2GHz.

  13. Elevated cystatin C: is it a reflection for kidney or liver impairment in hepatic children?

    Science.gov (United States)

    El-Sayed, Behairy; El-Araby, Hanaa; Adawy, Nermin; Hassona, Mona; El-Nady, Naglaa; Zakaria, Haidy; Khedr, Mohammed

    2017-09-01

    To assess if elevated serum cystatin C (Cyst-C) is an indicator for renal or hepatic dysfunction in presence of liver fibrosis. Data of 50 children with chronic liver diseases (CLDs), out of which 25 were without renal impairment, and 25 with renal impairment were analyzed. Twenty healthy children served as a healthy control group. Routine investigations, creatinine clearance, hepatitis viral markers, abdominal ultrasonography, and liver biopsy were performed for patients with CLDs. Measurement of serum Cyst-C concentration by particle induced immunonephelometry were completed for both patients and control group. Results showed that serum Cyst-C is not correlated with the degree of hepatic impairment ( p > 0.05). Cyst-C levels were significantly higher in patients with renal impairment (3.66 ± 0.85) than those without (0.71 ± 0.12), and healthy control group (0.63 ± 0.85). Cystatin-C showed significant elevation in patients with severe fibrosis with renal impairment (3.66 ± 0.85) than those without (0.76 ± 0.04) ( p without renal impairment. Cyst-C > 2.34 mg/l predicting GFR 2.73 mg/l predicting GFR impairment in children with CLDs. Further studies are needed to estimate the accuracy of serum Cyst-C for early detection of renal impairment and close monitoring of the hepatic children.

  14. Developmental dysgraphia with profound hearing impairment: intervention by auditory methods enabled by cochlear implant.

    Science.gov (United States)

    Fukushima, Kunihiro; Kawasaki, Akihiro; Nagayasu, Rie; Kunisue, Kazuya; Maeda, Yukihide; Kariya, Shin; Kataoka, Yuko; Nishizaki, Kazunori

    2008-06-01

    Learning disability combined with hearing impairment (LDHI) is a poor prognostic factor for the language development of hearing impaired children after educational intervention. A typical example of a child with LDHI and effective interventions provided by cochlear implants are presented in this report. A case of congenital cytomegaloviral infection that showed dysgraphia as well as profound deafness was reported and an underlying visual processing problem diagnosed in the present case caused the patient's dysgraphia. The dysgraphia could be circumvented by the use of auditory memory fairly established by a cochlear implant.

  15. The microstructure and surface hardness of Ti6Al4V alloy implanted with nitrogen ions at an elevated temperature

    Energy Technology Data Exchange (ETDEWEB)

    Vlcak, Petr, E-mail: petr.vlcak@fs.cvut.cz [Department of Physics, Faculty of Mechanical Engineering, Czech Technical University in Prague, Technicka 4, 16607 Prague (Czech Republic); Cerny, Frantisek [Department of Physics, Faculty of Mechanical Engineering, Czech Technical University in Prague, Technicka 4, 16607 Prague (Czech Republic); Drahokoupil, Jan [Department of Metals, Institute of Physics, AS CR, v.v.i., Na Slovance 2, 182 21 Prague (Czech Republic); Sepitka, Josef [Department of Mechanics, Biomechanics and Mechatronics, Faculty of Mechanical Engineering, Czech Technical University in Prague, Technicka 4, 16607 Prague (Czech Republic); Tolde, Zdenek [Department of Materials Engineering, Faculty of Mechanical Engineering, Czech Technical University in Prague, Technicka 4, 16607 Prague (Czech Republic)

    2015-01-25

    Highlights: • The Ti6Al4V samples were implanted with 90 keV nitrogen ions. • The samples were annealed at 500 °C during the ion implantation process. • An elevated temperature increases the mobility of the atoms and the quantity of TiN. • The hardness showed a significant increase compared to room temperature implantation. - Abstract: The effect of an elevated temperature during nitrogen ion implantation on the microstructure and on the surface hardness of Ti6Al4V titanium alloy was examined. The implantation process was carried out at fluences of 1 ⋅ 10{sup 17}, 2.7 ⋅ 10{sup 17} and 6 ⋅ 10{sup 17} cm{sup −2} and at ion energy 90 keV. The implanted samples were annealed at 500 °C during the implantation process. X-ray diffraction analysis was performed to obtain a phase characterization and a phase quantification in the implanted sample surface. The surface hardness was investigated by nanoindentation testing, and the nitrogen depth distribution was measured by Rutherford Backscattering Spectroscopy. Elevated temperature led to increased formation of a TiN compound. It was found that a mixture of TiN and an α-Ti(+N) solid solution had a predominant amount of TiN for samples with fluence of 2.7 ⋅ 10{sup 17} cm{sup −2} or higher. Elevated temperature during ion implantation caused an increase in surface hardening more towards the depth of the substrate in comparison with room temperature implantation. The hardness showed a remarkably significant increase at a fluence of 1 ⋅ 10{sup 17} and 2.7 ⋅ 10{sup 17} cm{sup −2} compared to samples implanted at the same fluences and at room temperature. There is a discussion of such mechanisms that explain the observed hardening more towards the depth of the substrate, and the increase in hardness.

  16. Demographic factors influencing educational placement of the hearing-impaired child with a cochlear implant.

    Science.gov (United States)

    Yehudai, Noam; Tzach, Naama; Shpak, Talma; Most, Tova; Luntz, Michal

    2011-08-01

    To analyze educational placement settings of Israeli children with cochlear implants (CIs) and evaluate the prognostic influence of the following demographic variables on mainstreaming: age at implantation, experience with CI, socioeconomic status, ethnicity, and parents' educational level. Retrospective review. Tertiary referral center. The study population comprised 245 children with severe-to-profound hearing impairment and at least 1 year of experience with a unilateral CI. Mean age at implantation was 4.5 ± 3.9 years, and mean duration of CI use was 5.4 ± 2.8 years. Follow-up review and statistical analysis of available data on educational placement after cochlear implantation. Placement in mainstream education. Regular schools were attended by 89 children (36.3%) and special education schools by 156 (63.7%). Variables found to be significantly associated with mainstream educational placement were younger age at implantation, higher level of parental education, higher socioeconomic status, and ethnicity. Multivariate analysis using a logistic regression model revealed that the factor with the highest positive correlation with mainstreaming was parental education level. Our results show that parental education, a variable that the health system cannot control, significantly influences postimplantation results in term of educational placement and can thus limit the chances of implanted children to achieve mainstream placement even when identified and implanted at an early age.

  17. Elevated 20-HETE impairs coronary collateral growth in metabolic syndrome via endothelial dysfunction.

    Science.gov (United States)

    Joseph, Gregory; Soler, Amanda; Hutcheson, Rebecca; Hunter, Ian; Bradford, Chastity; Hutcheson, Brenda; Gotlinger, Katherine H; Jiang, Houli; Falck, John R; Proctor, Spencer; Schwartzman, Michal Laniado; Rocic, Petra

    2017-03-01

    Coronary collateral growth (CCG) is impaired in metabolic syndrome (MetS). microRNA-145 (miR-145-Adv) delivery to our rat model of MetS (JCR) completely restored and neutrophil depletion significantly improved CCG. We determined whether low endogenous levels of miR-145 in MetS allowed for elevated production of 20-hydroxyeicosatetraenoic acid (20-HETE), which, in turn, resulted in excessive neutrophil accumulation and endothelial dysfunction leading to impaired CCG. Rats underwent 0-9 days of repetitive ischemia (RI). RI-induced cardiac CYP4F (neutrophil-specific 20-HETE synthase) expression and 20-HETE levels were increased (4-fold) in JCR vs. normal rats. miR-145-Adv and 20-HETE antagonists abolished and neutrophil depletion (blocking antibodies) reduced (~60%) RI-induced increases in CYP4F expression and 20-HETE production in JCR rats. Impaired CCG in JCR rats (collateral-dependent blood flow using microspheres) was completely restored by 20-HETE antagonists [collateral-dependent zone (CZ)/normal zone (NZ) flow ratio was 0.76 ± 0.07 in JCR + 20-SOLA, 0.84 ± 0.05 in JCR + 20-HEDGE vs. 0.11 ± 0.02 in JCR vs. 0.84 ± 0.03 in normal rats]. In JCR rats, elevated 20-HETE was associated with excessive expression of endothelial adhesion molecules and neutrophil infiltration, which were reversed by miR-145-Adv. Endothelium-dependent vasodilation of coronary arteries, endothelial nitric oxide synthase (eNOS) Ser1179 phosphorylation, eNOS-dependent NO ·- production and endothelial cell survival were compromised in JCR rats. These parameters of endothelial dysfunction were completely reversed by 20-HETE antagonism or miR-145-Adv delivery, whereas neutrophil depletion resulted in partial reversal (~70%). We conclude that low miR-145 in MetS allows for increased 20-HETE, mainly from neutrophils, which compromises endothelial cell survival and function leading to impaired CCG. 20-HETE antagonists could provide viable therapy for restoration of CCG in MetS. NEW & NOTEWORTHY

  18. Alternativas a la elevación de seno maxilar: implantes cortos Alternatives to maxillary sinus elevation: short implants

    Directory of Open Access Journals (Sweden)

    J. González Lagunas

    2008-12-01

    Full Text Available La mala calidad del hueso, reabsorciones extremas y la presencia de la cavidad del seno maxilar constituían obstáculos insalvables para la rehabilitación implanto-soportada en el sector posterior del maxilar atrófico. La elevación de seno es probablemente la primera opción de tratamiento en el paciente tributario de rehabilitación con implantes en ese sector. El uso de implantes cortos (menos de 10 mm se ha asociado tradicionalmente con unas tasas de supervivencia menores que la de los implantes largos. No obstante la aparición de nuevas superficies y diseños indican que este tipo de implantes puede soportar de forma fiable restauraciones dentales. Presentamos la técnica de instalación de implantes de superficie porosa sinterizada, asi como una revisión actualizada sobre el comportamiento de los implantes cortos.Poor bone quality, extreme bony resorption and a pneumatized mqxillary sinus are a severe Challenger for reconstruction of the atrophic edentuous posterior maxilla. Sinus lift is probably the gold standard for Management of that area. Short implants (<10mm have traditionally been associated with lower survival rates. The introduction of new surfaces and designs indicate that this type of implants can adequately support dental restorations. We present the technique of installation of sinterised porous dental implants together with an update on the behaviour of short implants.

  19. Motor Skills in Hearing Impaired Children with or without Cochlear Implant--A Systematic Review.

    Science.gov (United States)

    Vidranski, Tihomir; Farkaš, Daria

    2015-07-01

    Hearing impairment is a major limitation in communication, and it can obstruct psychological development, development of social skills and motor development. Hearing impairment is the third most common contemporary chronic health condition, and it has become a public health problem. The effectiveness of problem solving in everyday life and in emergency situations depends greatly on the amount and quality of the motor programs. Therefore, it is evident that the normal motor development in persons with hearing impairment is essential for everyday life. The aim of this research is to analyze the available information pertaining to motor skills of hearing impaired children both with and without a cochlear implant (CI) and to analyze possibilities of influencing their motor skills. The relevant studies on motor skills of hearing impaired children both with and without CI were obtained by an extensive computer search of various databases using special keywords and extraction with respect to certain criteria, resulting in 22 studies. The overall results of this systematic review indicate that the children with hearing impairment exhibit suboptimal levels of motor skills especially balance. Very few studies compared children with hearing impairment with CI units and without CI units and the results of those studies are quite contradictory. Numerous studies have confirmed that the regular and appropriate physical exercise can improve motor skills of children with hearing impairment, especially balance. The fact that the development of motor skills is crucial for the child's interaction with the outside world, action, perception and acquisition of academic skills and other skills necessary for life shows the importance of motor skills development for children with hearing impairment.

  20. Elevation of endogenous anandamide impairs LTP, learning, and memory through CB1 receptor signaling in mice.

    Science.gov (United States)

    Basavarajappa, Balapal S; Nagre, Nagaraja N; Xie, Shan; Subbanna, Shivakumar

    2014-07-01

    In rodents, many exogenous and endogenous cannabinoids, such as anandamide (AEA) and 2-arachidonyl glycerol (2-AG), have been shown to play an important role in certain hippocampal memory processes. However, the mechanisms by which endogenous AEA regulate this processes are not well understood. Here the effects of AEA on long-term potentiation (LTP), hippocampal-dependent learning and memory tasks, pERK1/2, pCaMKIV, and pCREB signaling events in both cannabinoid receptor type 1 (CB1R) wild-type (WT) and knockout (KO) mice were assessed following administration of URB597, an inhibitor of the fatty acid amide hydrolase (FAAH). Acute administration of URB597 enhanced AEA levels without affecting the levels of 2-AG or CB1R in the hippocampus and neocortex as compared to vehicle. In hippocampal slices, URB597 impaired LTP in CB1R WT but not in KO littermates. URB597 impaired object recognition, spontaneous alternation and spatial memory in the Y-maze test in CB1R WT mice but not in KO mice. Furthermore, URB597 enhanced ERK phosphorylation in WT without affecting total ERK levels in WT or KO mice. URB597 impaired CaMKIV and CREB phosphorylation in WT but not in KO mice. CB1R KO mice have a lower pCaMKIV/CaMKIV ratio and higher pCREB/CREB ratio as compared to WT littermates. Our results indicate that pharmacologically elevated AEA impair LTP, learning and memory and inhibit CaMKIV and CREB phosphorylation, via the activation of CB1Rs. Collectively, these findings also suggest that pharmacological elevation of AEA beyond normal concentrations is also detrimental for the underlying physiological responses. © 2014 Wiley Periodicals, Inc.

  1. Memory-impairing effects of local anesthetics in an elevated plus-maze test in mice

    Directory of Open Access Journals (Sweden)

    S.L. Blatt

    1998-04-01

    Full Text Available Post-training intracerebroventricular administration of procaine (20 µg/µl and dimethocaine (10 or 20 µg/µl, local anesthetics of the ester class, prolonged the latency (s in the retention test of male and female 3-month-old Swiss albino mice (25-35 g body weight; N = 140 in the elevated plus-maze (mean ± SEM for 10 male mice: control = 41.2 ± 8.1; procaine = 78.5 ± 10.3; 10 µg/µl dimethocaine = 58.7 ± 12.3; 20 µg/µl dimethocaine = 109.6 ± 5.73; for 10 female mice: control = 34.8 ± 5.8; procaine = 55.3 ± 13.4; 10 µg/µl dimethocaine = 59.9 ± 12.3 and 20 µg/µl dimethocaine = 61.3 ± 11.1. However, lidocaine (10 or 20 µg/µl, an amide class type of local anesthetic, failed to influence this parameter. Local anesthetics at the dose range used did not affect the motor coordination of mice exposed to the rota-rod test. These results suggest that procaine and dimethocaine impair some memory process(es in the plus-maze test. These findings are interpreted in terms of non-anesthetic mechanisms of action of these drugs on memory impairment and also confirm the validity of the elevated plus-maze for the evaluation of drugs affecting learning and memory in mice

  2. Studies in RF power communication, SAR, and temperature elevation in wireless implantable neural interfaces.

    Directory of Open Access Journals (Sweden)

    Yujuan Zhao

    Full Text Available Implantable neural interfaces are designed to provide a high spatial and temporal precision control signal implementing high degree of freedom real-time prosthetic systems. The development of a Radio Frequency (RF wireless neural interface has the potential to expand the number of applications as well as extend the robustness and longevity compared to wired neural interfaces. However, it is well known that RF signal is absorbed by the body and can result in tissue heating. In this work, numerical studies with analytical validations are performed to provide an assessment of power, heating and specific absorption rate (SAR associated with the wireless RF transmitting within the human head. The receiving antenna on the neural interface is designed with different geometries and modeled at a range of implanted depths within the brain in order to estimate the maximum receiving power without violating SAR and tissue temperature elevation safety regulations. Based on the size of the designed antenna, sets of frequencies between 1 GHz to 4 GHz have been investigated. As expected the simulations demonstrate that longer receiving antennas (dipole and lower working frequencies result in greater power availability prior to violating SAR regulations. For a 15 mm dipole antenna operating at 1.24 GHz on the surface of the brain, 730 uW of power could be harvested at the Federal Communications Commission (FCC SAR violation limit. At approximately 5 cm inside the head, this same antenna would receive 190 uW of power prior to violating SAR regulations. Finally, the 3-D bio-heat simulation results show that for all evaluated antennas and frequency combinations we reach FCC SAR limits well before 1 °C. It is clear that powering neural interfaces via RF is possible, but ultra-low power circuit designs combined with advanced simulation will be required to develop a functional antenna that meets all system requirements.

  3. Elevated Temperature and CO2 Stimulate Late-Season Photosynthesis But Impair Cold Hardening in Pine[OPEN

    Science.gov (United States)

    2016-01-01

    Rising global temperature and CO2 levels may sustain late-season net photosynthesis of evergreen conifers but could also impair the development of cold hardiness. Our study investigated how elevated temperature, and the combination of elevated temperature with elevated CO2, affected photosynthetic rates, leaf carbohydrates, freezing tolerance, and proteins involved in photosynthesis and cold hardening in Eastern white pine (Pinus strobus). We designed an experiment where control seedlings were acclimated to long photoperiod (day/night 14/10 h), warm temperature (22°C/15°C), and either ambient (400 μL L−1) or elevated (800 μmol mol−1) CO2, and then shifted seedlings to growth conditions with short photoperiod (8/16 h) and low temperature/ambient CO2 (LTAC), elevated temperature/ambient CO2 (ETAC), or elevated temperature/elevated CO2 (ETEC). Exposure to LTAC induced down-regulation of photosynthesis, development of sustained nonphotochemical quenching, accumulation of soluble carbohydrates, expression of a 16-kD dehydrin absent under long photoperiod, and increased freezing tolerance. In ETAC seedlings, photosynthesis was not down-regulated, while accumulation of soluble carbohydrates, dehydrin expression, and freezing tolerance were impaired. ETEC seedlings revealed increased photosynthesis and improved water use efficiency but impaired dehydrin expression and freezing tolerance similar to ETAC seedlings. Sixteen-kilodalton dehydrin expression strongly correlated with increases in freezing tolerance, suggesting its involvement in the development of cold hardiness in P. strobus. Our findings suggest that exposure to elevated temperature and CO2 during autumn can delay down-regulation of photosynthesis and stimulate late-season net photosynthesis in P. strobus seedlings. However, this comes at the cost of impaired freezing tolerance. Elevated temperature and CO2 also impaired freezing tolerance. However, unless the frequency and timing of extreme low

  4. Causes of hearing impairment in the Norwegian paediatric cochlear implant program.

    Science.gov (United States)

    Siem, Geir; Fagerheim, Toril; Jonsrud, Christoffer; Laurent, Claude; Teig, Erik; Harris, Sten; Leren, Trond P; Früh, Andreas; Heimdal, Ketil

    2010-08-01

    Severe to profound hearing impairment (HI) is estimated to affect around 1/2000 young children. Advances in genetics have made it possible to identify several genes related to HI. This information can cast light upon prognostic factors regarding the outcome in cochlear implantation, and provide information both for scientific and genetic counselling purposes. From 1992 to 2005, 273 children from 254 families (probands) were offered cochlear implants in Norway. An evaluation of the causes of HI, especially regarding the genes GJB2, GJB6, SLC26A4, KCNQ1, KCNE1, and the mutation A1555G in mitochondrial DNA was performed in 85% of the families. The number of probands with unknown cause of HI was thus reduced from 120 to 68 (43% reduction). Ninety-eight (46%) of the probands had an identified genetic etiology of their HI. A relatively high prevalence of Jervell and Lange-Nielsen syndrome was found. The main causes of severe and profound HI were similar to those found in other European countries. GJB2 mutations are a common cause of prelingual HI in Norwegian cochlear implanted children.

  5. Impaired bone formation in ovariectomized mice reduces implant integration as indicated by longitudinal in vivo micro-computed tomography.

    Science.gov (United States)

    Li, Zihui; Kuhn, Gisela; Schirmer, Michael; Müller, Ralph; Ruffoni, Davide

    2017-01-01

    Although osteoporotic bone, with low bone mass and deteriorated bone architecture, provides a less favorable mechanical environment than healthy bone for implant fixation, there is no general agreement on the impact of osteoporosis on peri-implant bone (re)modeling, which is ultimately responsible for the long term stability of the bone-implant system. Here, we inserted an implant in a mouse model mimicking estrogen deficiency-induced bone loss and we monitored with longitudinal in vivo micro-computed tomography the spatio-temporal changes in bone (re)modeling and architecture, considering the separate contributions of trabecular, endocortical and periosteal surfaces. Specifically, 12 week-old C57BL/6J mice underwent OVX/SHM surgery; 9 weeks after we inserted special metal-ceramics implants into the 6th caudal vertebra and we measured bone response with in vivo micro-CT weekly for the following 6 weeks. Our results indicated that ovariectomized mice showed a reduced ability to increase the thickness of the cortical shell close to the implant because of impaired peri-implant bone formation, especially at the periosteal surface. Moreover, we observed that healthy mice had a significantly higher loss of trabecular bone far from the implant than estrogen depleted animals. Such behavior suggests that, in healthy mice, the substantial increase in peri-implant bone formation which rapidly thickened the cortex to secure the implant may raise bone resorption elsewhere and, specifically, in the trabecular network of the same bone but far from the implant. Considering the already deteriorated bone structure of estrogen depleted mice, further bone loss seemed to be hindered. The obtained knowledge on the dynamic response of diseased bone following implant insertion should provide useful guidelines to develop advanced treatments for osteoporotic fracture fixation based on local and selective manipulation of bone turnover in the peri-implant region.

  6. Impaired bone formation in ovariectomized mice reduces implant integration as indicated by longitudinal in vivo micro-computed tomography.

    Directory of Open Access Journals (Sweden)

    Zihui Li

    Full Text Available Although osteoporotic bone, with low bone mass and deteriorated bone architecture, provides a less favorable mechanical environment than healthy bone for implant fixation, there is no general agreement on the impact of osteoporosis on peri-implant bone (remodeling, which is ultimately responsible for the long term stability of the bone-implant system. Here, we inserted an implant in a mouse model mimicking estrogen deficiency-induced bone loss and we monitored with longitudinal in vivo micro-computed tomography the spatio-temporal changes in bone (remodeling and architecture, considering the separate contributions of trabecular, endocortical and periosteal surfaces. Specifically, 12 week-old C57BL/6J mice underwent OVX/SHM surgery; 9 weeks after we inserted special metal-ceramics implants into the 6th caudal vertebra and we measured bone response with in vivo micro-CT weekly for the following 6 weeks. Our results indicated that ovariectomized mice showed a reduced ability to increase the thickness of the cortical shell close to the implant because of impaired peri-implant bone formation, especially at the periosteal surface. Moreover, we observed that healthy mice had a significantly higher loss of trabecular bone far from the implant than estrogen depleted animals. Such behavior suggests that, in healthy mice, the substantial increase in peri-implant bone formation which rapidly thickened the cortex to secure the implant may raise bone resorption elsewhere and, specifically, in the trabecular network of the same bone but far from the implant. Considering the already deteriorated bone structure of estrogen depleted mice, further bone loss seemed to be hindered. The obtained knowledge on the dynamic response of diseased bone following implant insertion should provide useful guidelines to develop advanced treatments for osteoporotic fracture fixation based on local and selective manipulation of bone turnover in the peri-implant region.

  7. Prevalence of sinus floor elevation procedures and survival rates of implants placed in the posterior maxilla

    Directory of Open Access Journals (Sweden)

    Ceyda Ozçakır Tomruk

    2016-01-01

    Full Text Available The aim of this study was to assess the prevalence of sinus-lifting procedures and survival rates of implants placed in the posterior maxilla. This retrospective chart review examined consecutive patients with tooth/teeth loss in the posterior maxilla between 2008 and 2012 treated with sinus lift, when needed, and implant insertion. Demographic variables, health status, residual alveolar bone height, augmentation types, the implant position, diameter and height, and implant failure, prosthesis types, and the marginal bone loss were recorded. The study included 302 patients at a mean age of 5.2 years, who received a total of 609 dental implants. A total of 380 (62.3% implants were inserted in native areas, 203 (33.3% ones in external sinus-lifted areas and 26 (4.4% ones in internal lifted areas. The survival rate in native or internal lifted areas were 100% and 95.6% in external sinus lifted ones (10 implant failures/203 implants. Almost half of the implants were examined radiologically with a mean duration of 30 months and the mean marginal bone loss was 0.64 ± 1.2 mm. The results showed that the survival rates of native bone and the internal sinus lifting were slightly higher than that of external sinus lifting. Implants placed with sinus augmentation exhibited more marginal bone loss than implants in native bone.

  8. Technical devices for hearing-impaired individuals: cochlear implants and brain stem implants - developments of the last decade.

    Science.gov (United States)

    Müller, Joachim

    2005-01-01

    Over the past two decades, the fascinating possibilities of cochlear implants for congenitally deaf or deafened children and adults developed tremendously and created a rapidly developing interdisciplinary research field.The main advancements of cochlear implantation in the past decade are marked by significant improvement of hearing and speech understanding in CI users. These improvements are attributed to the enhancement of speech coding strategies.The Implantation of more (and increasingly younger) children as well as the possibilities of the restoration of binaural hearing abilities with cochlear implants reflect the high standards reached by this development. Despite this progress, modern cochlear implants do not yet enable normal speech understanding, not even for the best patients. In particular speech understanding in noise remains problematic [1]. Until the mid 1990ies research concentrated on unilateral implantation. Remarkable and effective improvements have been made with bilateral implantation since 1996. Nowadays an increasing numbers of patients enjoy these benefits.

  9. Hearing-impaired children in the United Kingdom, III : cochlear implantation and the economic costs incurred by families

    OpenAIRE

    Barton, GR; Fortnum, HM; Stacey, PC; Summerfield, AQ

    2006-01-01

    Objectives: This article addresses two questions. First, are there differences in the economic costs incurred by families of hearing-impaired children depending on whether or not children have cochlear implants? Second, are these differences important when assessed from the perspective of society? Methods: In a cross-sectional survey, parents of a representative sample of hearing-impaired children provided data about annual resources used by the family because of their child’s hearing impairm...

  10. Symptomatic heart failure is the most important clinical correlate of impaired quality of life, anxiety, and depression in implantable cardioverter-defibrillator patients

    DEFF Research Database (Denmark)

    Johansen, Jens B; Pedersen, Susanne S.; Spindler, Helle

    2008-01-01

    To identify correlates of impaired quality of life (QOL), anxiety, and depression in patients with an implantable cardioverter-defibrillator (ICD).......To identify correlates of impaired quality of life (QOL), anxiety, and depression in patients with an implantable cardioverter-defibrillator (ICD)....

  11. Displacement of a dental implant into the maxillary sinus after internal sinus floor elevation: report of a case and review of literature.

    Science.gov (United States)

    Ding, Xiaojun; Wang, Qing; Guo, Xuehua; Yu, Youcheng

    2015-01-01

    Dental implant placement in the posterior maxilla may be complicated by implant migration into the maxillary sinus. To report the clinical and radiological characteristics of a patient who experienced dental implant displacement into the maxillary sinus following sinus floor elevation, and to compare our findings with those of other published reports of the displacement of dental implants. Implant placement and maxillary sinus elevation were performed simultaneously. The location of the displaced implant was monitored for 8 years, until the ectopic implant was surgically removed using the lateral window approach. The contributing factors, treatment modality, and clinical outcome for our patient were compared with those of patients reported in the literature. The clinical characteristics of our case were similar to those of patients with displaced implants who were also asymptomatic for long periods. The clinical outcome of our case was consistent with that of patients who underwent similar surgeries. Transnasal endoscopic removal of an ectopic implant may be suitable in cases in which the ectopic implant is accessible. Transoral direct approaches are adequate in most cases in which endoscopic approaches may be confounded. The bony-window transoral technique may allow the removal of large implants.

  12. Maxillary sinus floor elevation surgery with BioOss (R) mixed with a bone marrow concentrate or autogenous bone : test of principle on implant survival and clinical performance

    NARCIS (Netherlands)

    Rickert, D.; Vissink, A.; Slot, Jan; Sauerbier, S.; Meijer, H. J. A.; Raghoebar, G. M.

    The purpose of this study was to assess implant survival and 1-year clinical performance of implants placed in the posterior maxilla that had been subjected to maxillary sinus floor elevation surgery with bovine bone mineral (BioOss (R)) mixed with autogenous bone marrow concentrate or autogenous

  13. Sinus Floor Elevation with Modified Crestal Approach and Single Loaded Short Implants: A Case Report with 4 Years of Follow-Up

    Directory of Open Access Journals (Sweden)

    Michele Perelli

    2017-01-01

    Full Text Available Tooth extraction is usually followed by bone reduction. In the maxillary posterior region, this remodelling combined with sinus pneumatisation and periodontal defects may lead to a reduced basal bone height available for implant placement. Sinus floor elevation can be performed with different surgical techniques. Crestal approach has demonstrated to be effective, less invasive, and associated with a reduced morbidity. This article reports a modified sinus floor elevation by means of rotary, noncutting instruments, addition of xenograft, and 2 short-threaded implant placements. The aim of the study was to evaluate the implant’s success and intrasinus radiographical bone gain after 4 years of functional loading. The premolar implant site presented a starting basal bone height of 6 mm, while the molar site was of 2 mm. In the first surgical step, sinus floor elevation was performed mesially and the implant was inserted, and distally only sinus floor elevation was performed. After 6 months, the mesial implant was uncovered and the second implant was inserted; 4 months later, the second fixture was uncovered, and both fixtures were loaded with single provisional screw-retained crowns and later with single screw-retained porcelain fused to metal crowns. Implants integrated successfully, and crestal bone remodelling did not exceed the smooth collar. Bone gain was 3 mm for the mesial implant and more than 5 mm for the distal one.

  14. Impaired Perception of Sensory Consonance and Dissonance in Cochlear Implant Users.

    Science.gov (United States)

    Caldwell, Meredith T; Jiradejvong, Patpong; Limb, Charles J

    2016-03-01

    In light of previous research demonstrating poor pitch perception in cochlear implant (CI) users, we hypothesized that the presence of consonant versus dissonant chord accompaniment in real-world musical stimuli would not impact subjective assessment of degree of pleasantness in CI users. Consonance/dissonance are perceptual features of harmony resulting from pitch relationships between simultaneously presented musical notes. Generally, consonant sounds are perceived as pleasant and dissonant ones as unpleasant. CI users exhibit impairments in pitch perception, making music listening difficult and often unenjoyable. To our knowledge, consonance/dissonance perception has not been studied in the CI population. Twelve novel melodies were created for this study. By altering the harmonic structures of the accompanying chords, we created three permutations of varying dissonance for each melody (36 stimuli in all). Ten CI users and 12 NH listeners provided Likert scale ratings from -5 (very unpleasant) to +5 (very pleasant) for each of the stimuli. A two-way ANOVA showed main effects for Dissonance Level and Subject Type as well as a two-way interaction between the two. Pairwise comparisons indicated that NH stimuli pleasantness ratings decreased with increasing dissonance, whereas CI ratings did not. NH pleasantness ratings were consistently lower than CI ratings. For CI users, consonant versus dissonant chord accompaniment had no significant impact on whether a melody was considered pleasant or unpleasant. This finding may be partially responsible for the decreased enjoyment of many CI users during music perception and is another manifestation of impaired pitch perception in CI users.

  15. Long-term outcome after drug-eluting versus bare-metal stent implantation in patients with ST-segment elevation myocardial infarction

    DEFF Research Database (Denmark)

    Holmvang, Lene; Kelbæk, Henning; Kaltoft, Anne Kjer

    2013-01-01

    This study sought to compare the long-term effects of drug-eluting stent (DES) compared with bare-metal stent (BMS) implantation in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention.......This study sought to compare the long-term effects of drug-eluting stent (DES) compared with bare-metal stent (BMS) implantation in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention....

  16. Risk of Microgravity-Induced Visual Impairment and Elevated Intracranial Pressure (VIIP)

    Science.gov (United States)

    Otto, Christian

    2011-01-01

    Eight cases identified, represent 23.5% of the 34 crewmembers flown on the ISS, with inflight visual changes and pre-to-postflight refractive changes. In some cases, the changes were transient while in others they are persistent with varying degrees of visual impairment. (1) Decreased intraocular pressure (IOP) postflight was observed in 3 cases. (2) Fundoscopic exams revealed postflight findings of choroidal folds in 4 cases, optic disc edema in 5 cases and presence of cotton wool spots in 3 cases. (3) Optical coherence tomography (OCT) confirmed findings of choroidal folds and disc edema and documented retinal nerve fiber layer thickening (4 cases). (4) Findings from MRI examinations showed posterior globe flattening (5 cases) and optic nerve sheath distension (6 cases). (5) Opening cerebrospinal fluid (CSF) pressure was elevated in 4 cases postflight reflecting raised intracranial pressure. While the etiology remains unknown, hypotheses speculate that venous insufficiency or hypertension in the brain caused by cephalad fluid shifts during spaceflight are possible mechanisms for ocular changes in astronauts.

  17. Dysregulated LIF-STAT3 pathway is responsible for impaired embryo implantation in a Streptozotocin-induced diabetic mouse model

    Directory of Open Access Journals (Sweden)

    Tong-Song Wang

    2015-07-01

    Full Text Available The prevalence of diabetes is increasing worldwide with the trend of patients being young and creating a significant burden on health systems, including reproductive problems, but the effects of diabetes on embryo implantation are still poorly understood. Our study was to examine effects of diabetes on mouse embryo implantation, providing experimental basis for treating diabetes and its complications. Streptozotocin (STZ was applied to induce type 1 diabetes from day 2 of pregnancy or pseudopregnancy in mice. Embryo transfer was used to analyze effects of uterine environment on embryo implantation. Our results revealed that the implantation rate is significantly reduced in diabetic mice compared to controls, and the change of uterine environment is the main reason leading to the decreased implantation rate. Compared to control, the levels of LIF and p-STAT3 are significantly decreased in diabetic mice on day 4 of pregnancy, and serum estrogen level is significantly higher. Estrogen stimulates LIF expression under physiological level, but the excessive estrogen inhibits LIF expression. LIF, progesterone or insulin supplement can rescue embryo implantation in diabetic mice. Our data indicated that the dysregulated LIF-STAT3 pathway caused by the high level of estrogen results in the impaired implantation in diabetic mice, which can be rescued by LIF, progesterone or insulin supplement.

  18. Deferred versus conventional stent implantation in patients with ST-segment elevation myocardial infarction (DANAMI 3-DEFER)

    DEFF Research Database (Denmark)

    Kelbæk, Henning; Høfsten, Dan Eik; Køber, Lars

    2016-01-01

    to assess the clinical outcomes of deferred stent implantation versus standard PCI in patients with STEMI. METHODS: We did this open-label, randomised controlled trial at four primary PCI centres in Denmark. Eligible patients (aged >18 years) had acute onset symptoms lasting 12 h or less, and ST......-segment elevation of 0·1 mV or more in at least two or more contiguous electrocardiographic leads or newly developed left bundle branch block. Patients were randomly assigned (1:1), via an electronic web-based system with permuted block sizes of two to six, to receive either standard primary PCI with immediate...

  19. Impaired expression of importin/karyopherin β1 leads to post-implantation lethality

    International Nuclear Information System (INIS)

    Miura, Katsutaka; Yoshinobu, Kumiko; Imaizumi, Takashi; Haruna, Kyoko; Miyamoto, Yoichi; Yoneda, Yoshihiro; Nakagata, Naomi; Araki, Masatake; Miyakawa, Taihei; Yamamura, Ken-ichi; Araki, Kimi

    2006-01-01

    Importin β1 (Impβ)/karyopherin β1 (Kpnb1) mediates the nuclear import of a large variety of substrates. This study aimed to investigate the requirement for the Kpnb1 gene in mouse development, using a gene trap line, B6-CB-Ayu8108 GtgeoIMEG (Ayu8108 geo ), in which the trap vector was inserted into the promoter region of the Kpnb1 gene, but in reverse orientation of the Kpnb1 gene. Ayu8108 geo/geo homozygous embryos could develop to the blastocyst stage, but died before embryonic day 5.5, and expression of the Kpnb1 gene in homozygous blastocysts was undetectable. We also replaced the βgeo gene with Impβ cDNA through Cre-mediated recombination to rescue Impβ expression. Homozygous mice for the rescued allele Ayu8108 Impβ/Impβ were born and developed normally. These results demonstrated that the cause of post-implantation lethality of Ayu8108 geo/geo homozygous embryos was impaired expression of the Kpnb1 gene, indicating indispensable roles of Impβ1 in early development of mice

  20. Transient ST-segment elevation in precordial leads by acute marginal branch occlusion during stent implantation.

    Science.gov (United States)

    Arzola, Leidimar Carballo; Esteban, Marcos T Rodríguez; Niebla, Javier García

    2016-01-01

    The isolated right ventricular infarction is a rare entity. Our case presented a selective occlusion of an acute marginal branch that supplies the right ventricular free wall with isolated ST elevation in precordial leads simulating an occlusion of the left anterior descending artery and without pseudonormalization in inferior due to the non-involvement of the main branch in the ischemic process. Our case clearly illustrates a rare differential diagnosis when a new ST segment elevation appears in earlier precordial leads in patients with symptoms of myocardial ischemia. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Impaired perception of temporal fine structure and musical timbre in cochlear implant users.

    Science.gov (United States)

    Heng, Joseph; Cantarero, Gabriela; Elhilali, Mounya; Limb, Charles J

    2011-10-01

    Cochlear implant (CI) users demonstrate severe limitations in perceiving musical timbre, a psychoacoustic feature of sound responsible for 'tone color' and one's ability to identify a musical instrument. The reasons for this limitation remain poorly understood. In this study, we sought to examine the relative contributions of temporal envelope and fine structure for timbre judgments, in light of the fact that speech processing strategies employed by CI systems typically employ envelope extraction algorithms. We synthesized "instrumental chimeras" that systematically combined variable amounts of envelope and fine structure in 25% increments from two different source instruments with either sustained or percussive envelopes. CI users and normal hearing (NH) subjects were presented with 150 chimeras and asked to determine which instrument the chimera more closely resembled in a single-interval two-alternative forced choice task. By combining instruments with similar and dissimilar envelopes, we controlled the valence of envelope for timbre identification and compensated for envelope reconstruction from fine structure information. Our results show that NH subjects utilize envelope and fine structure interchangeably, whereas CI subjects demonstrate overwhelming reliance on temporal envelope. When chimeras were created from dissimilar envelope instrument pairs, NH subjects utilized a combination of envelope (p = 0.008) and fine structure information (p = 0.009) to make timbre judgments. In contrast, CI users utilized envelope information almost exclusively to make timbre judgments (p < 0.001) and ignored fine structure information (p = 0.908). Interestingly, when the value of envelope as a cue was reduced, both NH subjects and CI users utilized fine structure information to make timbre judgments (p < 0.001), although the effect was quite weak in CI users. Our findings confirm that impairments in fine structure processing underlie poor perception of musical timbre in CI

  2. Deferred stent implantation in patients with ST-segment elevation myocardial infarction

    DEFF Research Database (Denmark)

    Kelbæk, Henning; Engstrøm, Thomas; Ahtarovski, Kiril A

    2013-01-01

    Disturbance in the flow of an infarct-related artery due to embolisation of thrombus and plaque material occurs frequently during primary percutaneous coronary intervention (PCI) and is associated with impaired prognosis. The aim of the present study was to minimise the risk of embolisation durin...

  3. Th1, Th17, CXCL16 and homocysteine elevated after intracranial and cervical stent implantation.

    Science.gov (United States)

    Tang, Yanyan; Wei, Yunfei; Ye, Ziming; Qin, Chao

    2017-08-01

    The presence of Th1 and Th17 cells has been observed as major inducers in inflammation and immune responses associated stenting. However, there is rare data on the impact of Th1, Th17, CXCL16 and homocysteine after cerebral stent implantation. Here, we performed the statistical analysis to first evaluate the variation of the Th17and Th1 cells and their related cytokines, CXCL16 and homocysteine in the peripheral blood of patients with cerebral stenting. The flow cytometry was used to detect the proportion of Th1 and Th17 cells in peripheral blood mononuclear cells (PBMCs). The enzyme-linked immunosorbent assay was used to measure the serum concentrations of IFN-γ, IL-17 and CXCL16. Plasma homocysteine was examined by immunoturbidimetry. The level of Th1, CXCL16 and homocysteine showed an increase at 3 d, followed by the continuous decrease at 7 d and 3 months. The frequency of Th17 cells increased to a peak at three days, and subsequently decreased with a higher level than baseline. Our data revealed that the variation in Th1, Th17, CXCL16 and homocysteine in peripheral blood of patients with stenting may be implicated in inflammation after intracranial and cervical stent implantation. A better understanding of these factors will provide help for further drug design and clinical therapy.

  4. Stent Thrombosis is the Primary Cause of ST-Segment Elevation Myocardial Infarction following Coronary Stent Implantation

    DEFF Research Database (Denmark)

    Kristensen, Søren Lund; Galløe, Anders M; Thuesen, Leif

    2014-01-01

    Background: The widespread use of coronary stents has exposed a growing population to the risk of stent thrombosis, but the importance in terms of risk of ST-segment elevation myocardial infarctions (STEMIs) remains unclear. Methods: We studied five years follow-up data for 2,098 all-comer patients...... treated with coronary stents in the randomized SORT OUT II trial (mean age 63.6 yrs. 74.8% men). Patients who following stent implantation were readmitted with STEMI were included and each patient was categorized ranging from definite-to ruled-out stent thrombosis according to the Academic Research...... Consortium definitions. Multivariate logistic regression was performed on selected covariates to assess odds ratios (ORs) for definite stent thrombosis. Results: 85 patients (4.1%), mean age 62.7 years, 77.1% men, were admitted with a total of 96 STEMIs, of whom 60 (62.5%) had definite stent thrombosis...

  5. Elevated tropospheric CO2 and O3 concentrations impair organic pollutant removal from grassland soil.

    Science.gov (United States)

    Ai, Fuxun; Eisenhauer, Nico; Jousset, Alexandre; Butenschoen, Olaf; Ji, Rong; Guo, Hongyan

    2018-04-03

    The concentrations of tropospheric CO 2 and O 3 have been rising due to human activities. These rising concentrations may have strong impacts on soil functions as changes in plant physiology may lead to altered plant-soil interactions. Here, the effects of eCO 2 and eO 3 on the removal of polycyclic aromatic hydrocarbon (PAH) pollutants in grassland soil were studied. Both elevated CO 2 and O 3 concentrations decreased PAH removal with lowest removal rates at elevated CO 2 and elevated O 3 concentrations. This effect was linked to a shift in soil microbial community structure by structural equation modeling. Elevated CO 2 and O 3 concentrations reduced the abundance of gram-positive bacteria, which were tightly linked to soil enzyme production and PAH degradation. Although plant diversity did not buffer CO 2 and O 3 effects, certain soil microbial communities and functions were affected by plant communities, indicating the potential for longer-term phytoremediation approaches. Results of this study show that elevated CO 2 and O 3 concentrations may compromise the ability of soils to degrade organic pollutants. On the other hand, the present study also indicates that the targeted assembly of plant communities may be a promising tool to shape soil microbial communities for the degradation of organic pollutants in a changing world.

  6. Caffeine prevents weight gain and cognitive impairment caused by a high-fat diet while elevating hippocampal BDNF

    OpenAIRE

    Moy, Gregory A.; McNay, Ewan C.

    2012-01-01

    Obesity, high-fat diets, and subsequent type 2 diabetes (T2DM) are associated with cognitive impairment. Moreover, T2DM increases the risk of Alzheimer’s disease (AD) and leads to abnormal elevation of brain beta-amyloid levels, one of the hallmarks of AD. The psychoactive alkaloid caffeine has been shown to have therapeutic potential in AD but the central impact of caffeine has not been well-studied in the context of a high-fat diet. Here we investigated the impact of caffeine administration...

  7. Prevalence, predictors, and prognostic implications of residual impairment of functional capacity after transcatheter aortic valve implantation

    NARCIS (Netherlands)

    M. Abdelghani (Mohammad); R. Cavalcante (Rafael); Y. Miyazaki (Yosuke); R.J. de Winter (Robbert); R. Sarmento-Leite (Rogerio); J.A. Mangione (José A.); A.C. Abizaid (Alexandre); P.A. Lemos Neto (Pedro); P.W.J.C. Serruys (Patrick); F.S. De Brito Jr. (Fabio)

    2017-01-01

    markdownabstractBackground: Patients with degenerative aortic stenosis (AS) referred for transcatheter aortic valve implantation (TAVI) typically have advanced cardiac and vascular adverse remodeling and multiple comorbidities and, therefore, might not recover a normal functional capacity after

  8. Prevalence, predictors, and prognostic implications of residual impairment of functional capacity after transcatheter aortic valve implantation

    NARCIS (Netherlands)

    Abdelghani, Mohammad; Cavalcante, Rafael; Miyazaki, Yosuke; de Winter, Robbert J.; Sarmento-Leite, Rogério; Mangione, José A.; Abizaid, Alexandre; Lemos, Pedro A.; Serruys, Patrick W.; de Brito, Fabio S.

    2017-01-01

    Background Patients with degenerative aortic stenosis (AS) referred for transcatheter aortic valve implantation (TAVI) typically have advanced cardiac and vascular adverse remodeling and multiple comorbidities and, therefore, might not recover a normal functional capacity after valve replacement. We

  9. Understanding minds: early cochlear implantation and the development of theory of mind in children with profound hearing impairment.

    Science.gov (United States)

    Sundqvist, Annette; Lyxell, Björn; Jönsson, Radoslava; Heimann, Mikael

    2014-03-01

    The present study investigates how auditory stimulation from cochlear implants (CI) is associated with the development of Theory of Mind (ToM) in severely and profoundly hearing impaired children with hearing parents. Previous research has shown that deaf children of hearing parents have a delayed ToM development. This is, however, not always the case with deaf children of deaf parents, who presumably are immersed in a more vivid signing environment. Sixteen children with CI (4.25 to 9.5 years of age) were tested on measures of cognitive and emotional ToM, language and cognition. Eight of the children received their first implant relatively early (before 27 months) and half of them late (after 27 months). The two groups did not differ in age, gender, language or cognition at entry of the study. ToM tests included the unexpected location task and a newly developed Swedish social-emotional ToM test. The tests aimed to test both cognitive and emotional ToM. A comparison group of typically developing hearing age matched children was also added (n=18). Compared to the comparison group, the early CI-group did not differ in emotional ToM. The late CI-group differed significantly from the comparison group on both the cognitive and emotional ToM tests. The results revealed that children with early cochlear implants solved ToM problems to a significantly higher degree than children with late implants, although the groups did not differ on language or cognitive measures at baseline. The outcome suggests that early cochlear implantation for deaf children in hearing families, in conjunction with early social and communicative stimulation in a language that is native to the parents, can provide a foundation for a more normalized ToM development. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. Akita spontaneously type 1 diabetic mice exhibit elevated vascular arginase and impaired vascular endothelial and nitrergic function.

    Science.gov (United States)

    Toque, Haroldo A; Nunes, Kenia P; Yao, Lin; Xu, Zhimin; Kondrikov, Dmitry; Su, Yunchao; Webb, R Clinton; Caldwell, Ruth B; Caldwell, R William

    2013-01-01

    Elevated arginase (Arg) activity is reported to be involved in diabetes-induced vascular endothelial dysfunction. It can reduce L-arginine availability to nitric oxide (NO) synthase (NOS) and NO production. Akita mice, a genetic non-obese type 1 diabetes model, recapitulate human diabetes. We determined the role of Arg in a time-course of diabetes-associated endothelial dysfunction in aorta and corpora cavernosa (CC) from Akita mice. Endothelium-dependent relaxation, Arg and NOS activity, and protein expression levels of Arg and constitutive NOS were assessed in aortas and CC from Akita and non-diabetic wild type (WT) mice at 4, 12 and 24 wks of age. Systolic blood pressure (SBP) was assessed by tail cuff. In aorta and CC, Akita mice exhibited a progressive impairment of vascular endothelial and nitrergic function increased Arg activity and expression (Arg1 in aorta and both Arg1 and Arg2 in CC) compared with that of age-matched WT mice. Treatment of aorta and CC from Akita mice with an Arg inhibitor (BEC or ABH) reduced diabetes-induced elevation of Arg activity and restored endothelial and nitrergic function. Reduced levels of phospho-eNOS at Ser(1177) (in aorta and CC) and nNOS expression (in CC) were observed in Akita mice at 12 and 24 wks. Akita mice also had decreased NOS activity in aorta and CC at 12 and 24 wks that was restored by BEC treatment. Further, Akita mice exhibited moderately increased SBP at 24 wks and increased sensitivity to PE-induced contractions in aorta and sympathetic nerve stimulation in CC at 12 and 24 wks. Over 24 wks of diabetes in Akita mice, both aortic and cavernosal tissues exhibited increased Arg activity/expression, contributing to impaired endothelial and nitrergic function and reduced NO production. Our findings demonstrate involvement of Arg activity in diabetes-induced impairment of vascular function in Akita mouse.

  11. Akita spontaneously type 1 diabetic mice exhibit elevated vascular arginase and impaired vascular endothelial and nitrergic function.

    Directory of Open Access Journals (Sweden)

    Haroldo A Toque

    Full Text Available Elevated arginase (Arg activity is reported to be involved in diabetes-induced vascular endothelial dysfunction. It can reduce L-arginine availability to nitric oxide (NO synthase (NOS and NO production. Akita mice, a genetic non-obese type 1 diabetes model, recapitulate human diabetes. We determined the role of Arg in a time-course of diabetes-associated endothelial dysfunction in aorta and corpora cavernosa (CC from Akita mice.Endothelium-dependent relaxation, Arg and NOS activity, and protein expression levels of Arg and constitutive NOS were assessed in aortas and CC from Akita and non-diabetic wild type (WT mice at 4, 12 and 24 wks of age. Systolic blood pressure (SBP was assessed by tail cuff. In aorta and CC, Akita mice exhibited a progressive impairment of vascular endothelial and nitrergic function increased Arg activity and expression (Arg1 in aorta and both Arg1 and Arg2 in CC compared with that of age-matched WT mice. Treatment of aorta and CC from Akita mice with an Arg inhibitor (BEC or ABH reduced diabetes-induced elevation of Arg activity and restored endothelial and nitrergic function. Reduced levels of phospho-eNOS at Ser(1177 (in aorta and CC and nNOS expression (in CC were observed in Akita mice at 12 and 24 wks. Akita mice also had decreased NOS activity in aorta and CC at 12 and 24 wks that was restored by BEC treatment. Further, Akita mice exhibited moderately increased SBP at 24 wks and increased sensitivity to PE-induced contractions in aorta and sympathetic nerve stimulation in CC at 12 and 24 wks.Over 24 wks of diabetes in Akita mice, both aortic and cavernosal tissues exhibited increased Arg activity/expression, contributing to impaired endothelial and nitrergic function and reduced NO production. Our findings demonstrate involvement of Arg activity in diabetes-induced impairment of vascular function in Akita mouse.

  12. Lateral approach for maxillary sinus membrane elevation without bone materials in maxillary mucous retention cyst with immediate or delayed implant rehabilitation: case reports.

    Science.gov (United States)

    Han, Ji-Deuk; Cho, Seong-Ho; Jang, Kuk-Won; Kim, Seong-Gwang; Kim, Jung-Han; Kim, Bok-Joo; Kim, Chul-Hun

    2017-08-01

    This case series study demonstrates the possibility of successful implant rehabilitation without bone augmentation in the atrophic posterior maxilla with cystic lesion in the sinus. Sinus lift without bone graft using the lateral approach was performed. In one patient, the cyst was aspirated and simultaneous implantation under local anesthesia was performed, whereas the other cyst was removed under general anesthesia, and the sinus membrane was elevated in a second process, followed by implantation. In both cases, tapered 11.5-mm-long implants were utilized. With all of the implants, good stability and appropriate bone height were achieved. The mean bone level gain was 5.73 mm; adequate bone augmentation around the implants was shown, the sinus floor was moved apically, and the cyst was no longer radiologically detected. Completion of all of the treatments required an average of 12.5 months. The present study showed that sufficient bone formation and stable implantation in a maxilla of insufficient bone volume are possible through sinus lift without bone materials. The results serve to demonstrate, moreover, that surgical treatment of mucous retention cyst can facilitate rehabilitation. These techniques can reduce the risk of complications related to bone grafts, save money, and successfully treat antral cyst.

  13. Ahmed Versus Baerveldt Glaucoma Drainage Implantation in Patients With Markedly Elevated Intraocular Pressure (≥30 mm Hg).

    Science.gov (United States)

    Resende, Arthur F; Moster, Marlene R; Patel, Neal S; Lee, Daniel; Dhami, Hermandeep; Pro, Michael J; Waisbourd, Michael

    2016-09-01

    Glaucoma patients with markedly elevated intraocular pressure (IOP) are at risk for developing severe hypotony-related complications. The goal of this study was to compare the surgical outcomes of the Ahmed Glaucoma Valve (AGV) and the Baerveldt Glaucoma Implant (BGI) in this patient population. Patients with preoperative IOP≥30 mm Hg were included. Outcome measures were: (1) surgical failure (IOP>21 mm Hg or glaucoma surgery, or loss of light perception) and (2) surgical complications. A total of 75 patients were included: 37 in the AGV group and 38 in the BGI group. The mean±SD follow-up was 2.3±1.6 years for the AGV group and 2.4±1.7 years for the BGI group (P=0.643). Mean preoperative IOP was 38.7±6.5 mm Hg for the AGV group and 40.8±7.6 mm Hg for the BGI group. At the last follow-up, 10 (27.0%) patients failed in the AGV group compared with 6 (15.8%) patients in the BGI group (P=0.379). The BGI group had higher rate of flat or shallow anterior chamber (n=4, 10%) compared with the AGV group (n=0, 0%) (P=0.043). Failure rates of AGV and BGI in patients with IOP≥30 mm Hg were comparable. There were more early hypotony-related complications in the BGI group; however, none were vision threatening. Both glaucoma drainage implants were effective in treating patients with uncontrolled glaucoma in an emergency setting.

  14. Exposure to elevated sea-surface temperatures below the bleaching threshold impairs coral recovery and regeneration following injury.

    Science.gov (United States)

    Bonesso, Joshua Louis; Leggat, William; Ainsworth, Tracy Danielle

    2017-01-01

    Elevated sea surface temperatures (SSTs) are linked to an increase in the frequency and severity of bleaching events due to temperatures exceeding corals' upper thermal limits. The temperatures at which a breakdown of the coral- Symbiodinium endosymbiosis (coral bleaching) occurs are referred to as the upper thermal limits for the coral species. This breakdown of the endosymbiosis results in a reduction of corals' nutritional uptake, growth, and tissue integrity. Periods of elevated sea surface temperature, thermal stress and coral bleaching are also linked to increased disease susceptibility and an increased frequency of storms which cause injury and physical damage to corals. Herein we aimed to determine the capacity of corals to regenerate and recover from injuries (removal of apical tips) sustained during periods of elevated sea surface temperatures which result in coral stress responses, but which do not result in coral bleaching (i.e., sub-bleaching thermal stress events). In this study, exposure of the species Acropora aspera to an elevated SST of 32 °C (2 °C below the bleaching threshold, 34 °C) was found to result in reduced fluorescence of green fluorescent protein (GFP), reduced skeletal calcification and a lack of branch regrowth at the site of injury, compared to corals maintained under ambient SST conditions (26 °C). Corals maintained under normal, ambient, sea surface temperatures expressed high GFP fluorescence at the injury site, underwent a rapid regeneration of the coral branch apical tip within 12 days of sustaining injury, and showed extensive regrowth of the coral skeleton. Taken together, our results have demonstrated that periods of sustained increased sea surface temperatures, below the corals' bleaching threshold but above long-term summertime averages, impair coral recovery from damage, regardless of the onset or occurrence of coral bleaching.

  15. Elevated occipital β-amyloid deposition is associated with widespread cognitive impairment in logopenic progressive aphasia.

    Science.gov (United States)

    Whitwell, Jennifer L; Lowe, Val J; Duffy, Joseph R; Strand, Edythe A; Machulda, Mary M; Kantarci, Kejal; Wille, Samantha M; Senjem, Matthew L; Murphy, Matthew C; Gunter, Jeffrey L; Jack, Clifford R; Josephs, Keith A

    2013-12-01

    Most subjects with logopenic variant of primary progressive aphasia (lvPPA) have β-amyloid (Aβ) deposition on Pittsburgh Compound B positron emission tomography (PiB-PET), usually affecting prefrontal and temporoparietal cortices, with less occipital involvement. To assess clinical and imaging features in lvPPA subjects with unusual topographic patterns of Aβ deposition with highest uptake in occipital lobe. Thirty-three lvPPA subjects with Aβ deposition on PiB-PET were included in this case-control study. Line plots of regional PiB uptake were created, including frontal, temporal, parietal and occipital regions, for each subject. Subjects in which the line sloped downwards in occipital lobe (lvPPA-low), representing low uptake, were separated from those where the line sloped upwards in occipital lobe (lvPPA-high), representing unusually high occipital uptake compared to other regions. Clinical variables, atrophy on MRI, hypometabolism on 18F-fluorodeoxyglucose positron emission tomography (FDG-PET), and presence and distribution of microbleeds and white matter hyperintensities (WMHs) were assessed. Seventeen subjects (52%) were classified as lvPPA-high. Mean occipital PiB uptake in lvPPA-high was higher than all other regions and higher than all regions in lvPPA-low. The lvPPA-high subjects performed more poorly on cognitive testing, including executive and visuospatial testing, but the two groups did not differ in aphasia severity. Proportion of microbleeds and WMH was higher in lvPPA-high than lvPPA-low. Parietal hypometabolism was greater in lvPPA-high than lvPPA-low. Unusually high occipital Aβ deposition is associated with widespread cognitive impairment and different imaging findings in lvPPA. These findings help explain clinical heterogeneity in lvPPA and suggest that Aβ influences severity of overall cognitive impairment but not aphasia.

  16. Graft shrinkage and survival rate of implants after sinus floor elevation using a nanocrystalline hydroxyapatite embedded in silica gel matrix: a 1-year prospective study.

    Science.gov (United States)

    El Hage, Marc; Abi Najm, Semaan; Bischof, Mvark; Nedir, Rabah; Carrel, Jean-Pierre; Bernard, Jean-Pierre

    2012-06-01

    The aims of this study were (1) to evaluate the vertical shrinkage percentage of nanocrystalline hydroxyapatite embedded in silica gel used for maxillary sinus floor elevation (SFE) and (2) to determine the survival rate of the implants 1 year after placement in the healed grafted sinuses. Eleven maxillary sinuses were augmented in eight patients with NanoBone. After a healing period averaging 14.42 months, 19 implants were placed and followed up with clinical and radiographic evaluation. Panoramic radiographs were taken immediately after SFE and at 12 months after grafting. Measurements of changes in height were made by a computerized measuring technique using an image editing software. The mean graft height shrinkage percentage at 12 months after surgery was 8.84% (±5.32). One implant was lost before loading. All the 18 remaining osseointegrated implants received the prosthetic rehabilitation and were controlled after 3 months of functional loading. The implant survival rate at the 1-year interval was 94.74%. A 100% NanoBone alloplastic graft used in lateral SFE procedures presented limited height shrinkage. Implants placed in these grafted sinuses showed survival rates similar to those found in published data. These results should be interpreted cautiously considering the study's reduced sample size.

  17. Study of deuterium retention in/release from ITER-relevant Be-containing mixed material layers implanted at elevated temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Sugiyama, K., E-mail: kazuyoshi.sugiyama@ipp.mpg.de [Max-Planck-Institut für Plasmaphysik, EURATOM Association, D-85748 Garching (Germany); Porosnicu, C. [National Institute for Laser, Plasma and Radiation Physics, EURATOM-MEdC Association, 077125 Bucharest (Romania); Jacob, W.; Roth, J.; Dürbeck, Th. [Max-Planck-Institut für Plasmaphysik, EURATOM Association, D-85748 Garching (Germany); Jepu, I.; Lungu, C.P. [National Institute for Laser, Plasma and Radiation Physics, EURATOM-MEdC Association, 077125 Bucharest (Romania)

    2013-07-15

    D implantation into Be-containing mixed material layers: Be, Be–W (W: ∼6 at.%) and Be–C (C: ∼50 at.%), was performed at elevated temperatures. The temperature dependence of D retention varied depending on the admixed element. D retention in Be and Be–W layers decreases with increasing implantation temperature, while the Be–C layers maintained rather high D retention in the present investigated temperature range (up to 623 K). D desorption behaviour from Be–C suggests the contribution of C–D bonds to D retention. W admixture into Be can significantly suppress D retention in Be. Long-term isothermal annealing at 513 and 623 K for D removal was also performed to simulate the ITER-wall-baking scenario. Even extended annealing at temperatures comparable to or lower than the implantation temperature does not lead to a significant release of retained D.

  18. Important Factors in the Cognitive Development of Children with Hearing Impairment: Case Studies of Candidates for Cochlear Implants

    Directory of Open Access Journals (Sweden)

    Nasralla, Heloisa Romeiro

    2014-06-01

    Full Text Available Introduction The factors that affect the development of children with and without hearing disabilities are similar, provided their innate communication abilities are taken into account. Parents need to mourn the loss of the expected normally hearing child, and it is important that parents create bonds of affection with their child. Objective To conduct a postevaluation of the development and cognition of 20 candidates for cochlear implants between 1 and 13 years of age and to observe important factors in their development. Methods The following instruments were used in accordance with their individual merits: interviews with parents; the Vineland Social Maturity Scale; the Columbia Maturity Scale; free drawings; Bender and Pre-Bender testing; and pedagogical tests. Results The results are described. Conclusion Parental acceptance of a child's deafness proved to be the starting point for the child's verbal or gestural communication development, as well as for cognitive, motor, and emotional development. If the association between deafness and fine motor skills (with or without multiple disabilities undermines the development of a child's speech, it does not greatly affect communication when the child interacts with his or her peers and receives maternal stimulation. Overprotection and poor sociability make children less independent, impairs their development, and causes low self-esteem. Further observational studies are warranted to determine how cochlear implants contribute to patient recovery.

  19. Important factors in the cognitive development of children with hearing impairment: case studies of candidates for cochlear implants.

    Science.gov (United States)

    Nasralla, Heloisa Romeiro; Goffi Gomez, Maria Valéria Schimidt; Magalhaes, Ana Tereza; Bento, Ricardo Ferreira

    2014-10-01

    Introduction The factors that affect the development of children with and without hearing disabilities are similar, provided their innate communication abilities are taken into account. Parents need to mourn the loss of the expected normally hearing child, and it is important that parents create bonds of affection with their child. Objective To conduct a postevaluation of the development and cognition of 20 candidates for cochlear implants between 1 and 13 years of age and to observe important factors in their development. Methods The following instruments were used in accordance with their individual merits: interviews with parents; the Vineland Social Maturity Scale; the Columbia Maturity Scale; free drawings; Bender and Pre-Bender testing; and pedagogical tests. Results The results are described. Conclusion Parental acceptance of a child's deafness proved to be the starting point for the child's verbal or gestural communication development, as well as for cognitive, motor, and emotional development. If the association between deafness and fine motor skills (with or without multiple disabilities) undermines the development of a child's speech, it does not greatly affect communication when the child interacts with his or her peers and receives maternal stimulation. Overprotection and poor sociability make children less independent, impairs their development, and causes low self-esteem. Further observational studies are warranted to determine how cochlear implants contribute to patient recovery.

  20. Acute restriction impairs memory in the elevated T-maze (ETM) and modifies serotonergic activity in the dorsolateral striatum.

    Science.gov (United States)

    Cruz-Morales, Sara Eugenia; García-Saldívar, Norma Laura; González-López, María Reyes; Castillo-Roberto, Georgina; Monroy, Juana; Domínguez, Roberto

    2008-12-16

    Serotonin (5-HT) is involved in behaviors such as sleep, eating, memory, in mental disorders like anxiety and depression and plays an important role in the modulation of stress. On the other hand, exposure to stress influence learning as well as declarative and non-declarative memory. These effects are dependent on the type of stressor, their magnitude, and the type of memory. The striatum has been associated with non-declarative procedural memory, while the information about stress effects on procedural memory and their relation with striatal serotonin is scarce. The objective of this study was to evaluate the effects of stress on the modifications of the striatal serotonergic system. In Experiment 1, the effects of either 60 min of restraint (R) or exposure to the elevated T-maze (ETM) was assessed. Exposure to ETM decreased 5-HT concentration and to R increased 5-HT activity ([metabolite]/[neurotransmitter]). In Experiment 2, we evaluated the effects of restraint on ETM trained immediately, 24 or 48 h after restraint. No effects were detected in acquisition or escape latencies, while retention latencies were lower in all groups compared with the non-restrained group, although significant effects were detected immediately and 24h after restraint. The memory impairment seems to be associated with changes in striatal serotonergic system, given that 5-HT concentration increased, while serotonergic activity decreased. The differences in the activity of 5-HT detected in each experiment could be explained by the effects of different stressors on the serotonergic neurons ability to synthesize the neurotransmitter. Thus, we suggest that exposure to stress impairs procedural memory and that striatal serotonin modulates this effect.

  1. Elevated HLA-A expression impairs HIV control through inhibition of NKG2A-expressing cells.

    Science.gov (United States)

    Ramsuran, Veron; Naranbhai, Vivek; Horowitz, Amir; Qi, Ying; Martin, Maureen P; Yuki, Yuko; Gao, Xiaojiang; Walker-Sperling, Victoria; Del Prete, Gregory Q; Schneider, Douglas K; Lifson, Jeffrey D; Fellay, Jacques; Deeks, Steven G; Martin, Jeffrey N; Goedert, James J; Wolinsky, Steven M; Michael, Nelson L; Kirk, Gregory D; Buchbinder, Susan; Haas, David; Ndung'u, Thumbi; Goulder, Philip; Parham, Peter; Walker, Bruce D; Carlson, Jonathan M; Carrington, Mary

    2018-01-05

    The highly polymorphic human leukocyte antigen ( HLA ) locus encodes cell surface proteins that are critical for immunity. HLA-A expression levels vary in an allele-dependent manner, diversifying allele-specific effects beyond peptide-binding preference. Analysis of 9763 HIV-infected individuals from 21 cohorts shows that higher HLA-A levels confer poorer control of HIV. Elevated HLA-A expression provides enhanced levels of an HLA-A-derived signal peptide that specifically binds and determines expression levels of HLA-E, the ligand for the inhibitory NKG2A natural killer (NK) cell receptor. HLA-B haplotypes that favor NKG2A-mediated NK cell licensing (i.e., education) exacerbate the deleterious effect of high HLA-A on HIV control, consistent with NKG2A-mediated inhibition impairing NK cell clearance of HIV-infected targets. Therapeutic blockade of HLA-E:NKG2A interaction may yield benefit in HIV disease. Copyright © 2017, American Association for the Advancement of Science.

  2. Optical and electronic properties of sub-surface conducting layers in diamond created by MeV B-implantation at elevated temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Willems van Beveren, L. H., E-mail: laurensw@unimelb.edu.au; Bowers, H.; Ganesan, K.; Johnson, B. C.; McCallum, J. C.; Prawer, S. [School of Physics, University of Melbourne, Parkville, Victoria 3010 (Australia); Liu, R. [SIMS Facility, Office of the Deputy-Vice Chancellor (Research and Development) Western Sydney University, Locked Bag 1797, Penrith, New South Wales 2751 (Australia)

    2016-06-14

    Boron implantation with in-situ dynamic annealing is used to produce highly conductive sub-surface layers in type IIa (100) diamond plates for the search of a superconducting phase transition. Here, we demonstrate that high-fluence MeV ion-implantation, at elevated temperatures avoids graphitization and can be used to achieve doping densities of 6 at. %. In order to quantify the diamond crystal damage associated with implantation Raman spectroscopy was performed, demonstrating high temperature annealing recovers the lattice. Additionally, low-temperature electronic transport measurements show evidence of charge carrier densities close to the metal-insulator-transition. After electronic characterization, secondary ion mass spectrometry was performed to map out the ion profile of the implanted plates. The analysis shows close agreement with the simulated ion-profile assuming scaling factors that take into account an average change in diamond density due to device fabrication. Finally, the data show that boron diffusion is negligible during the high temperature annealing process.

  3. Lexical and semantic ability in groups of children with cochlear implants, language impairment and autism spectrum disorder.

    Science.gov (United States)

    Löfkvist, Ulrika; Almkvist, Ove; Lyxell, Björn; Tallberg, Ing-Mari

    2014-02-01

    Lexical-semantic ability was investigated among children aged 6-9 years with cochlear implants (CI) and compared to clinical groups of children with language impairment (LI) and autism spectrum disorder (ASD) as well as to age-matched children with normal hearing (NH). In addition, the influence of age at implantation on lexical-semantic ability was investigated among children with CI. 97 children divided into four groups participated, CI (n=34), LI (n=12), ASD (n=12), and NH (n=39). A battery of tests, including picture naming, receptive vocabulary and knowledge of semantic features, was used for assessment. A semantic response analysis of the erroneous responses on the picture-naming test was also performed. The group of children with CI exhibited a naming ability comparable to that of the age-matched children with NH, and they also possessed a relevant semantic knowledge of certain words that they were unable to name correctly. Children with CI had a significantly better understanding of words compared to the children with LI and ASD, but a worse understanding than those with NH. The significant differences between groups remained after controlling for age and non-verbal cognitive ability. The children with CI demonstrated lexical-semantic abilities comparable to age-matched children with NH, while children with LI and ASD had a more atypical lexical-semantic profile and poorer sizes of expressive and receptive vocabularies. Dissimilar causes of neurodevelopmental processes seemingly affected lexical-semantic abilities in different ways in the clinical groups. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  4. An assessment of driving fitness in patients with visual impairment to understand the elevated risk of motor vehicle accidents.

    Science.gov (United States)

    Kunimatsu-Sanuki, Shiho; Iwase, Aiko; Araie, Makoto; Aoki, Yuki; Hara, Takeshi; Nakazawa, Toru; Yamaguchi, Takuhiro; Ono, Hiroshi; Sanuki, Tomoyuki; Itoh, Makoto

    2015-02-27

    To assess the driving fitness of patients with glaucoma by identifying specific areas and degrees of visual field impairment that threaten safe driving. Case-control study. This prospective study included 36 patients with advanced glaucoma, defined as Humphrey field analyzer (HFA; 24-2 SITA standard program) measurements of mean deviation in both eyes of worse than -12 dB, and 36 age-matched and driving exposure time-matched normal subjects. All participants underwent testing in a novel driving simulator (DS) system. Participants were recruited between September 2010 and January 2012. The number of collisions with simulated hazards and braking response time in 14 DS scenarios was recorded. Monocular HFA 24-2 test results from both eyes were merged to calculate the binocular integrated visual field (IVF). The position of the IVF subfields in which the collision-involved patients had lower sensitivity than the collision-uninvolved patients was compared with the track of the hazard. The cut-off value to predict an elevated risk of collisions was determined, as were its sensitivity and specificity, with the area under the receiver operating characteristic (AUROC) curve. Patients with advanced glaucoma were involved in a significantly higher number of collisions in the DS than the age-matched and driving exposure time-matched normal subjects (119 vs 40, respectively, p<0.0001), especially in four specific DS scenarios. In these four scenarios, IVF sensitivity was significantly lower in the collision-involved patients than in the collision-uninvolved patients in subfields on or near the track of the simulated hazard (p<0.05). The subfields with the largest AUROC curve had values ranging from 0.72 to 0.91 and were located in the paracentral visual field just below the horizontal. Our novel DS system effectively assessed visual impairment, showing that simulators may have future potential in educating patients. Published by the BMJ Publishing Group Limited. For

  5. Duodenal-jejunal bypass liner implantation provokes rapid weight loss and improved glycemic control, accompanied by elevated fasting ghrelin levels

    NARCIS (Netherlands)

    Koehestanie, P.; Dogan, K.; Berends, F.; Janssen, I.; Wahab, P.J.; Groenen, M.; Müller, M.R.; Wit, de N.J.W.

    2014-01-01

    Background and study aims: Endoscopic implantation of a duodenal-jejunal bypass liner (DJBL) is a novel bariatric technique to induce weight loss and remission of type 2 diabetes mellitus. Placement of the DJBL mimics the bypass component of the Roux-en-Y gastric bypass (RYGB) procedure. In this

  6. The mirostructure and surface hardness of Ti6Al4V alloy implanted with nitrogen ions at an elevated temperature

    Czech Academy of Sciences Publication Activity Database

    Vlčák, P.; Černý, F.; Drahokoupil, Jan; Sepitka, J.; Tolde, Z.

    2015-01-01

    Roč. 620, Jan (2015), 48-54 ISSN 0925-8388 Institutional support: RVO:68378271 Keywords : hardening * microstructure * phase identification * phase quantification * ion implantation * titanium alloy Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 3.014, year: 2015

  7. Eicosanoyl-5-hydroxytryptamide (EHT prevents Alzheimer's disease-related cognitive and electrophysiological impairments in mice exposed to elevated concentrations of oligomeric beta-amyloid.

    Directory of Open Access Journals (Sweden)

    Kesava Asam

    Full Text Available Soluble forms of oligomeric beta-amyloid (Aβ are thought to play a central role in Alzheimer's disease (AD. Transgenic manipulation of methylation of the serine/threonine protein phosphatase, PP2A, was recently shown to alter the sensitivity of mice to AD-related impairments resulting from acute exposure to elevated levels of Aβ. In addition, eicosanoyl-5-hydroxytryptamide (EHT, a naturally occurring component from coffee beans that modulates PP2A methylation, was shown to confer therapeutic benefits in rodent models of AD and Parkinson's disease. Here, we tested the hypothesis that EHT protects animals from the pathological effects of exposure to elevated levels of soluble oligomeric Aβ. We treated mice with EHT-containing food at two different doses and assessed the sensitivity of these animals to Aβ-induced behavioral and electrophysiological impairments. We found that EHT administration protected animals from Aβ-induced cognitive impairments in both a radial-arm water maze and contextual fear conditioning task. We also found that both chronic and acute EHT administration prevented Aβ-induced impairments in long-term potentiation. These data add to the accumulating evidence suggesting that interventions with pharmacological agents, such as EHT, that target PP2A activity may be therapeutically beneficial for AD and other neurological conditions.

  8. ASSOCIATION OF CARDIORESPIRATORY FITNESS WITH ELEVATED HEPATIC ENZYME AND LIVER FAT IN JAPANESE PATIENTS WITH IMPAIRED GLUCOSE TOLERANCE AND TYPE 2 DIABETES MELLITUS

    Directory of Open Access Journals (Sweden)

    Mayumi Nagano

    2010-09-01

    Full Text Available No study has so far determined whether a favorable level of cardiorespiratory fitness (CF contributes to a reduced risk of elevated hepatic enzymes and a high degree of liver fat in patients having various metabolic risks. This study investigated the association between the maximal oxygen uptake (VO2 max and the prevalence of elevated liver enzymes and high liver fat, while considering such factors as abdominal obesity, hyperinsulinemia and the other metabolic risks. The study enrolled newly diagnosed Japanese patients (n = 84; 52 males and 32 females; aged 25-69 years with impaired glucose tolerance (IGT and type 2 diabetes mellitus (Type2DM who did not receive any intervention or pharmacological therapy. The subjects were divided into 3 groups according to the distribution of the VO2max for each sex. The odds ratios (ORs for the prevalence of elevated aspartate and alanine aminotransferase (AST and ALT and high degree of liver fat adjusted for age, sex, disease type, daily ethanol intake, and current smoking were significantly lower in the moderate- and high CF groups in comparison to the low CF group. In addition, a significant OR for AST was maintained in the moderate and high CF group after adjusting for abdominal obesity and/or hyperinsulinemia. The significant ORs for the prevalence of elevated ALT and a high degree of liver fat were attenuated after adjusting for abdominal obesity and/or hyperinsulinemia. No significant OR for the prevalence of elevated gamma-glutamyl transferase (GGT was recognized in all logistic models. These results indicated that CF was negatively and independently associated with the prevalence of elevated AST even in Japanese diabetic patients having various metabolic risks. It was concluded that the AST level might be useful as a simple marker reflecting physical inactivity in such subjects

  9. Success and Failure Rates of 1,344 6- to 9-mm-Length Rough-Surface Implants Placed at the Time of Transalveolar Sinus Elevations, Restored with Single Crowns, and Followed for 60 to 229 Months in Function.

    Science.gov (United States)

    Fugazzotto, Paul A

    To assess the success and stability of 6-, 7-, 8-, and 9-mm-long, 6.5-mm-wide-neck tissue-level implants placed at the time of transalveolar sinus augmentation therapy, utilizing a trephine and osteotome approach, which were restored with single crowns. In total, 1,344 implants were placed by the author, varying in length from 6 to 9 mm, with parallel-wall 4.8-mm-diameter implant bodies and 6.5-mm-diameter implant necks. The implants were restored with single abutments and crowns by a variety of practitioners. They were followed for 60 to 229 months in function, with a mean time of 121.1 months in function. Implant success was evaluated by the author utilizing a combination of the Albrektsson et al criteria, and buccal and palatal/lingual bone sounding under anesthesia. The overall cumulative success rate was 98.8%. One hundred ninety 6-mm-long implants demonstrated a cumulative success rate of 97.5% at a mean time of 109.2 months in function. Eleven 7-mm-long implants demonstrated a cumulative success rate of 100% at a mean time of 218.5 months in function. One thousand ninety-four 8-mm-long implants demonstrated a cumulative success rate of 98.9% at a mean time of 112.3 months in function. Forty-nine 9-mm-long implants demonstrated a cumulative success rate of 100% at a mean time of 212.1 months in function. Implants of 6 to 9 mm in length, placed at the time of trephine and osteotome transalveolar sinus elevation procedures and restored with abutments and single crowns, demonstrate a high level of long-term clinical success, assuming specific comprehensive treatment criteria are met.

  10. Implantable cardioverter-defibrillators improve survival after coronary artery bypass grafting in patients with severely impaired left ventricular function

    Directory of Open Access Journals (Sweden)

    Pasque Michael K

    2007-01-01

    Full Text Available Abstract Objective Patients with severe left ventricular (LV dysfunction have a poor long term survival despite complete surgical revascularization. Recent data suggests that the use of Implantable Cardioverter-Defibrillator (ICD improves survival in patients with severe LV dysfunction. We compared the survival impact of ICD implantation in patients with severe LV dysfunction who underwent CABG. Methods Between January 1996 and August 2004, 305 patients with LV ejection fraction (EF ≤25% had CABG surgery at our institution. Demographics of patients who had received an ICD (ICD+ in the post -operative period was compared to those without ICD (ICD-. Survival was evaluated by the Kaplan-Meier method. Results Of the entire group, 35 (11.5% patients received an ICD with a median of 2 (+/-2 years after CABG. Indication for ICD implantation was clinical evidence of non sustained ventricular tachycardia (NSVT. There were no differences between the 2 groups with respect to age, gender, NYHA classification, number of bypasses, or other co-morbidities. Survival at 1, 3 and 5 years was 88%, 79%, and 67% for the ICD- group compared to 94%, 89% and 83% for the ICD+ group, respectively (figure, p Conclusion Implantation of ICD after CABG confers improved short and long term survival benefit to patients with severe LV dysfunction. Prophylactic ICD implantation in the setting of severe LV dysfunction and CABG surgery should be considered.

  11. Titanium Implant Impairment and Surrounding Muscle Cell Death Following High-Salt Diet: An In Vivo Study.

    Directory of Open Access Journals (Sweden)

    Mathieu Lecocq

    Full Text Available High-salt consumption has been widely described as a risk factor for cardiovascular, renal and bone functions. In the present study, the extent to which high-salt diet could influence Ti6Al4V implant surface characteristic, its adhesion to rat tibial crest, and could modify muscle cell viability of two surrounding muscles, was investigated in vivo. These parameters have also been assessed following a NMES (neuro-myoelectrostimulation program similar to that currently used in human care following arthroplasty.After a three-week diet, a harmful effect on titanium implant surface and muscle cell viability was noted. This is probably due to salt corrosive effect on metal and then release of toxic substance around biologic tissue. Moreover, if the use of NMES with high-salt diet induced muscles damages, the latter were higher when implant was added. Unexpectedly, higher implant-to-bone adhesion was found for implanted animals receiving salt supplementation.Our in vivo study highlights the potential dangerous effect of high-salt diet in arthroplasty based on titanium prosthesis. This effect appears to be more important when high-salt diet is combined with NMES.

  12. Brain implants for substituting lost motor function: state of the art and potential impact on the lives of motor-impaired seniors.

    Science.gov (United States)

    Ramsey, N F; Aarnoutse, E J; Vansteensel, M J

    2014-01-01

    Recent scientific achievements bring the concept of neural prosthetics for reinstating lost motor function closer to medical application. Current research involves severely paralyzed people under the age of 65, but implications for seniors with stroke or trauma-induced impairments are clearly on the horizon. Demographic changes will lead to a shortage of personnel to care for an increasing population of senior citizens, threatening maintenance of an acceptable level of care and urging ways for people to live longer at their home independent from personal assistance. This is particularly challenging when people suffer from disabilities such as partial paralysis after stroke or trauma, where daily personal assistance is required. For some of these people, neural prosthetics can reinstate some lost motor function and/or lost communication, thereby increasing independence and possibly quality of life. In this viewpoint article, we present the state of the art in decoding brain activity in the service of brain-computer interfacing. Although some noninvasive applications produce good results, we focus on brain implants that benefit from better quality brain signals. Fully implantable neural prostheses for home use are not available yet, but clinical trials are being prepared. More sophisticated systems are expected to follow in the years to come, with capabilities of interest for less severe paralysis. Eventually the combination of smart robotics and brain implants is expected to enable people to interact well enough with their environment to live an independent life in spite of motor disabilities. © 2014 S. Karger AG, Basel.

  13. Short-Term and Working Memory Impairments in Early-Implanted, Long-Term Cochlear Implant Users Are Independent of Audibility and Speech Production.

    Science.gov (United States)

    AuBuchon, Angela M; Pisoni, David B; Kronenberger, William G

    2015-01-01

    To determine whether early-implanted, long-term cochlear implant (CI) users display delays in verbal short-term and working memory capacity when processes related to audibility and speech production are eliminated. Twenty-three long-term CI users and 23 normal-hearing controls each completed forward and backward digit span tasks under testing conditions that differed in presentation modality (auditory or visual) and response output (spoken recall or manual pointing). Normal-hearing controls reproduced more lists of digits than the CI users, even when the test items were presented visually and the responses were made manually via touchscreen response. Short-term and working memory delays observed in CI users are not due to greater demands from peripheral sensory processes such as audibility or from overt speech-motor planning and response output organization. Instead, CI users are less efficient at encoding and maintaining phonological representations in verbal short-term memory using phonological and linguistic strategies during memory tasks.

  14. The Repeatable Battery for the Assessment of Neuropsychological Status for Hearing Impaired Individuals (RBANS-H) before and after Cochlear Implantation: A Protocol for a Prospective, Longitudinal Cohort Study.

    Science.gov (United States)

    Claes, Annes J; Mertens, Griet; Gilles, Annick; Hofkens-Van den Brandt, Anouk; Fransen, Erik; Van Rompaey, Vincent; Van de Heyning, Paul

    2016-01-01

    Background: Currently, an independent relationship between hearing loss and cognitive decline in older adults is suggested by large prospective studies. In general, cochlear implants improve hearing and the quality of life in severely to profoundly hearing impaired older persons. However, little is known about the effects of cochlear implantation on the cognitive evolution in this population. Aim of the study: The primary goal of this prospective, longitudinal cohort study is to explore the cognitive profile of severely to profoundly postlingually hearing impaired subjects before and after cochlear implantation. In addition, the current study aims to investigate the relationship between the cognitive function, audiometric performances, quality of life, and self-reliance in these patients. Methods: Twenty-five patients aged 55 or older, scheduled for cochlear implantation, will be enrolled in the study. They will be examined prior to implantation, at 6 and 12 months after implantation and annually thereafter. The test battery consists of (1) a cognitive examination, using the Repeatable Battery for the Assessment of Neuropsychological Status adapted for Hearing impaired persons (RBANS-H), (2) an audiological examination, including unaided and aided pure tone audiometry, speech audiometry in quiet and speech audiometry in noise, (3) the administration of four questionnaires evaluating quality of life and subjective hearing benefit and (4) a semi-structured interview about the self-reliance of the participant. Discussion: Up until now only one study has been conducted on this topic, focusing on the short-term effects of cochlear implantation on cognition in older adults. The present study is the first study to apply a comprehensive neuropsychological assessment adapted for severely to profoundly hearing impaired subjects in order to investigate the cognitive capabilities before and after cochlear implantation. Trial registration: The present protocol is

  15. Relationships of elevated systemic pentraxin-3 levels with high-risk coronary plaque components and impaired myocardial perfusion after percutaneous coronary intervention in patients with ST-elevation acute myocardial infarction.

    Science.gov (United States)

    Kimura, Shigeki; Inagaki, Hiroshi; Haraguchi, Go; Sugiyama, Tomoyo; Miyazaki, Toru; Hatano, Yu; Yoshikawa, Shunji; Ashikaga, Takashi; Isobe, Mitsuaki

    2014-01-01

    We aimed to assess the relationships of pentraxin-3 (PTX3) with coronary plaque components and myocardial perfusion after percutaneous coronary intervention (PCI) in order to clarify the mechanisms underlying the prognostic function of PTX3 in ST-elevation acute myocardial infarction (STEMI) patients. We enrolled 75 STEMI patients who underwent pre-PCI virtual histology (VH)-intravascular ultrasound. Relationships of the systemic pre-PCI PTX3 level with coronary plaque components and post-PCI myocardial blush grade (MBG) were evaluated. Lesions with elevated pre-PCI PTX3 (median ≥3.79ng/ml) had higher frequencies of VH-derived thin-cap fibroatheroma (65.8% vs. 24.3%, P2 on admission (hazard ratio, 5.356; 95% CI, 1.409-20.359; P=0.014) as independent predictors of adverse cardiac events during follow-up. Systemic pre-PCI PTX3 was associated with high-risk plaque components and impaired post-PCI myocardial perfusion. Thus, PTX3 may be a reliable predictor of outcome in STEMI patients.

  16. Low-dose thioperamide injected into the cerebellar vermis of mice immediately after exposure to the elevated plus-maze impairs their avoidance behavior on re-exposure to the apparatus

    Directory of Open Access Journals (Sweden)

    J. Costa Neto

    2013-11-01

    Full Text Available The present study investigated the effect of thioperamide (THIO, an H3 histaminergic receptor antagonist, microinjected into the cerebellar vermis on emotional memory consolidation in male Swiss albino mice re-exposed to the elevated plus-maze (EPM. We implanted a guide cannula into the cerebellar vermis using stereotactic surgery. On the third day after surgery, we performed behavioral tests for two consecutive days. On the first day (exposure, the mice (n=10/group were exposed to the EPM and received THIO (0.06, 0.3, or 1.5 ng/0.1 µL immediately after the end of the session. Twenty-four hours later, the mice were re-exposed to the EPM under the same experimental conditions, but without drug injection. A reduction in the exploration of the open arms upon re-exposure to the EPM (percentage of number of entries and time spent in open arms compared with the initial exposure was used as an indicator of learning and memory. One-way analysis of variance (ANOVA followed by the Duncan post hoc test was used to analyze the data. Upon re-exposure, exploratory activity in the open arms was reduced in the control group, and with the two highest THIO doses: 0.3 and 1.5 ng/0.1 µL. No reduction was seen with the lowest THIO dose (0.06 ng/0.1 µL, indicating inhibition of the consolidation of emotional memory. None of the doses interfered with the animals' locomotor activity. We conclude that THIO at the lowest dose (0.06 ng/0.1 µL microinjected into the cerebellum impaired emotional memory consolidation in mice.

  17. Morphological correlates of hearing loss after cochlear implantation and electro-acoustic stimulation in a hearing-impaired Guinea pig model.

    Science.gov (United States)

    Reiss, Lina A J; Stark, Gemaine; Nguyen-Huynh, Anh T; Spear, Kayce A; Zhang, Hongzheng; Tanaka, Chiemi; Li, Hongzhe

    2015-09-01

    Hybrid or electro-acoustic stimulation (EAS) cochlear implants (CIs) are designed to provide high-frequency electric hearing together with residual low-frequency acoustic hearing. However, 30-50% of EAS CI recipients lose residual hearing after implantation. The objective of this study was to determine the mechanisms of EAS-induced hearing loss in an animal model with high-frequency hearing loss. Guinea pigs were exposed to 24 h of noise (12-24 kHz at 116 dB) to induce a high-frequency hearing loss. After recovery, two groups of animals were implanted (n = 6 per group), with one group receiving chronic acoustic and electric stimulation for 10 weeks, and the other group receiving no stimulation during this time frame. A third group (n = 6) was not implanted, but received chronic acoustic stimulation. Auditory brainstem responses were recorded biweekly to monitor changes in hearing. The organ of Corti was immunolabeled with phalloidin, anti-CtBP2, and anti-GluR2 to quantify hair cells, ribbons and post-synaptic receptors. The lateral wall was immunolabeled with phalloidin and lectin to quantify stria vascularis capillary diameters. Bimodal or trimodal diameter distributions were observed; the number and location of peaks were objectively determined using the Aikake Information Criterion and Expectation Maximization algorithm. Noise exposure led to immediate hearing loss at 16-32 kHz for all groups. Cochlear implantation led to additional hearing loss at 4-8 kHz; this hearing loss was negatively and positively correlated with minimum and maximum peaks of the bimodal or trimodal distributions of stria vascularis capillary diameters, respectively. After chronic stimulation, no significant group changes in thresholds were seen; however, elevated thresholds at 1 kHz in implanted, stimulated animals were significantly correlated with decreased presynaptic ribbon and postsynaptic receptor counts. Inner and outer hair cell counts did not differ between groups and

  18. Characterization of silver colloids formed in LiBbO3 by Ag and O implantation at room and elevated temperatures

    International Nuclear Information System (INIS)

    Williams, E.K.; Ila, D.; Darwish, A.; Poker, D.B.; Sarkisov, S.S.; Curley, M.J.; Wang, J.-C.; Svetchnikov, V.L.; Zandbergen, H.W.

    1999-01-01

    To address the issue of dispersion of Ag colloids in LiNbO 3 at heat treatment temperatures of 400-500 deg. C, Ag and O were implanted at energies of 160 and 35 keV, respectively, at room temperature (Rt) and at 500 deg. C. Fluences were 4x10 16 and 8x10 16 /cm 2 and the order of the Ag and O implants was varied. Electron paramagnetic resonance spectra indicated that only O followed by Ag implantation of 500 deg. C produced silver oxide. Optical absorption spectrometry and RBS showed significant differences in the dispersion of the colloids with implant temperature and implant order. Implantation of Ag at 1.5 MeV to a fluence of 2x10 16 /cm 2 followed by heat treatment at 500 deg. C for 1 h produced nonlinear optical waveguides with a nonlinear index of the order of 10 -10 cm 2 /W at 532 nm

  19. Randomized controlled multicenter study comparing short dental implants (6 mm) versus longer dental implants (11-15 mm) in combination with sinus floor elevation procedures. Part 2: clinical and radiographic outcomes at 1 year of loading.

    Science.gov (United States)

    Schincaglia, Gian Pietro; Thoma, Daniel S; Haas, Robert; Tutak, Marcin; Garcia, Abel; Taylor, Thomas D; Hämmerle, Christoph H F

    2015-11-01

    To compare, clinically and radiographically, short dental implants (6 mm) to long implants (11-15 mm) placed with sinus grafting. Participants with 5-7 mm of bone height in the posterior maxilla were randomly allocated to receive short implants (GS) or long implants with sinus grafting (GG). Implants were loaded with single crowns 6 months after placement (PR). Patients were re-evaluated 12 months after loading (FU-1). Outcome variables included: Implant survival rate (CSR), marginal bone level alteration (MBL), periodontal probing depth (PPD), bleeding on probing (BoP), plaque control record (PCR) and crown-to-implant ratios (C/I). Statistical analysis was performed using parametric tests. In 97 subjects, 132 implants were re-evaluated at FU-1. The CSR was 100%. The MBL from implant placement (IP) to (PR) was -0.22 ± 0.4 mm for GG and -0.3 ± 0.45 mm for GS (p 0.05), PPD (p = 1) and PCR (p = 0.09). BoP was higher in the GS (p = 0.04). The C/I was 0.99 ± 0.17 for GG and 1.86 ± 0.23 for GS (p < 0.001). No correlation was observed between C/I and MBL, (GG: p = 0.13; GS: p = 0.38). Both treatment modalities provided similar outcomes. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Long-term outcome after drug-eluting versus bare-metal stent implantation in patients with ST-segment elevation myocardial infarction: 3-year follow-up of the randomized DEDICATION (Drug Elution and Distal Protection in Acute Myocardial Infarction) Trial

    DEFF Research Database (Denmark)

    Kaltoft, Anne; Kelbaek, Henning; Thuesen, Leif

    2010-01-01

    The purpose of this study was to compare long-term clinical outcomes after implantation of drug-eluting stents (DES) and bare-metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI).......The purpose of this study was to compare long-term clinical outcomes after implantation of drug-eluting stents (DES) and bare-metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI)....

  1. Relationship between spectrotemporal modulation detection and music perception in normal-hearing, hearing-impaired, and cochlear implant listeners.

    Science.gov (United States)

    Choi, Ji Eun; Won, Jong Ho; Kim, Cheol Hee; Cho, Yang-Sun; Hong, Sung Hwa; Moon, Il Joon

    2018-01-15

    The objective of this study was to examine the relationship between spectrotemporal modulation (STM) sensitivity and the ability to perceive music. Ten normal-nearing (NH) listeners, ten hearing aid (HA) users with moderate hearing loss, and ten cochlear Implant (CI) users participated in this study. Three different types of psychoacoustic tests including spectral modulation detection (SMD), temporal modulation detection (TMD), and STM were administered. Performances on these psychoacoustic tests were compared to music perception abilities. In addition, psychoacoustic mechanisms involved in the improvement of music perception through HA were evaluated. Music perception abilities in unaided and aided conditions were measured for HA users. After that, HA benefit for music perception was correlated with aided psychoacoustic performance. STM detection study showed that a combination of spectral and temporal modulation cues were more strongly correlated with music perception abilities than spectral or temporal modulation cues measured separately. No correlation was found between music perception performance and SMD threshold or TMD threshold in each group. Also, HA benefits for melody and timbre identification were significantly correlated with a combination of spectral and temporal envelope cues though HA.

  2. Impact of Moderate to Severe Renal Impairment on Mortality and Appropriate Shocks in Patients with Implantable Cardioverter Defibrillators

    Directory of Open Access Journals (Sweden)

    Venkata M. Alla

    2010-01-01

    Full Text Available Background. Due to underrepresentation of patients with chronic kidney disease (CKD in large Implantable-Cardioverter Defibrillator (ICD clinical trials, the impact of ICD remains uncertain in this population. Methods. Consecutive patients who received ICD at Creighton university medical center between years 2000–2004 were included in a retrospective cohort after excluding those on maintenance dialysis. Based on baseline Glomerular filtration rate (GFR, patients were classified as severe CKD: GFR < 30 mL/min; moderate CKD: GFR: 30–59 mL/min; and mild or no CKD: GFR ≥ 60 mL/min. The impact of GFR on appropriate shocks and survival was assessed using Kaplan-Meier method and Generalized Linear Models (GLM with log-link function. Results. There were 509 patients with a mean follow-up of 3.0 + 1.3 years. Mortality risk was inversely proportional to the estimated GFR: 2 fold higher risk with GFR between 30–59 mL/min and 5 fold higher risk with GFR < 30 mL/min. One hundred and seventy-seven patients received appropriate shock(s; appropriate shock-free survival was lower in patients with severe CKD (GFR < 30 compared to mild or no CKD group (2.8 versus 4.2 yrs. Conclusion. Even moderate renal dysfunction increases all cause mortality in CKD patients with ICD. Severe but not moderate CKD is an independent predictor for time to first appropriate shock.

  3. Elevating your elevator talk

    Science.gov (United States)

    An important and often overlooked item that every early career researcher needs to do is compose an elevator talk. The elevator talk, named because the talk should not last longer than an average elevator ride (30 to 60 seconds), is an effective method to present your research and yourself in a clea...

  4. Specific Language Impairment, Nonverbal IQ, Attention-Deficit/Hyperactivity Disorder, Autism Spectrum Disorder, Cochlear Implants, Bilingualism, and Dialectal Variants: Defining the Boundaries, Clarifying Clinical Conditions, and Sorting Out Causes.

    Science.gov (United States)

    Rice, Mabel L

    2016-02-01

    The purpose of this research forum article is to provide an overview of a collection of invited articles on the topic "specific language impairment (SLI) in children with concomitant health conditions or nonmainstream language backgrounds." Topics include SLI, attention-deficit/hyperactivity disorder, autism spectrum disorder, cochlear implants, bilingualism, and dialectal language learning contexts. The topic is timely due to current debates about the diagnosis of SLI. An overarching comparative conceptual framework is provided for comparisons of SLI with other clinical conditions. Comparisons of SLI in children with low-normal or normal nonverbal IQ illustrate the unexpected outcomes of 2 × 2 comparison designs. Comparative studies reveal unexpected relationships among speech, language, cognitive, and social dimensions of children's development as well as precise ways to identify children with SLI who are bilingual or dialect speakers. The diagnosis of SLI is essential for elucidating possible causal pathways of language impairments, risks for language impairments, assessments for identification of language impairments, linguistic dimensions of language impairments, and long-term outcomes. Although children's language acquisition is robust under high levels of risk, unexplained individual variations in language acquisition lead to persistent language impairments.

  5. Gender-related differences in outcome after BMS or DES implantation in patients with ST-segment elevation myocardial infarction treated by primary angioplasty

    DEFF Research Database (Denmark)

    De Luca, Giuseppe; Verdoia, Monica; Dirksen, Maurits T

    2013-01-01

    Several studies have found that among patients with ST-segment elevation myocardial infarction (STEMI) treated by thrombolysis, female sex is associated with a worse outcome. However, still controversial is the prognostic impact of gender in primary angioplasty, especially in the era of drug-elut...

  6. Increased susceptibility to metabolic dysregulation in a mouse model of Alzheimer's disease is associated with impaired hypothalamic insulin signaling and elevated BCAA levels.

    Science.gov (United States)

    Ruiz, Henry H; Chi, Tiffany; Shin, Andrew C; Lindtner, Claudia; Hsieh, Wilson; Ehrlich, Michelle; Gandy, Sam; Buettner, Christoph

    2016-08-01

    Epidemiologic studies have demonstrated an association between diabetes and dementia. Insulin signaling within the brain, in particular within the hypothalamus regulates carbohydrate, lipid, and branched chain amino acid (BCAA) metabolism in peripheral organs such as the liver and adipose tissue. We hypothesized that cerebral amyloidosis impairs central nervous system control of metabolism through disruption of insulin signaling in the hypothalamus, which dysregulates glucose and BCAA homeostasis resulting in increased susceptibility to diabetes. We examined whether APP/PS1 mice exhibit increased susceptibility to aging or high-fat diet (HFD)-induced metabolic impairment using metabolic phenotyping and insulin-signaling studies. APP/PS1 mice were more susceptible to high-fat feeding and aging-induced metabolic dysregulation including disrupted BCAA homeostasis and exhibited impaired hypothalamic insulin signaling. Our data suggest that AD pathology increases susceptibility to diabetes due to impaired hypothalamic insulin signaling, and that plasma BCAA levels could serve as a biomarker of hypothalamic insulin action in patients with AD. Copyright © 2016 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.

  7. Ion implantation

    International Nuclear Information System (INIS)

    Dearnaley, Geoffrey

    1975-01-01

    First, ion implantation in semiconductors is discussed: ion penetration, annealing of damage, gettering, ion implanted semiconductor devices, equipement requirements for ion implantation. The importance of channeling for ion implantation is studied. Then, some applications of ion implantation in metals are presented: study of the corrosion of metals and alloys; influence or ion implantation on the surface-friction and wear properties of metals; hyperfine interactions in implanted metals

  8. Study design of the influence of SErotonin inhibition on patients with RENAl impairment or diabetes undergoing drug-eluting stent implantation (SERENADE) study: A multicenter, open-label, prospective, randomized study.

    Science.gov (United States)

    Lee, Seung-Ah; Suh, Jung-Won; Park, Jin Joo; Yoon, Chang-Hwan; Cho, Young-Suk; Youn, Tae-Jin; Chae, In-Ho; Kim, Hyo-Soo; Kim, Sang-Hyun; Choi, Dong-Ju

    2015-07-01

    The rates of stent failure after percutaneous coronary intervention have decreased since the introduction of the drug-eluting stent (DES). However, chronic kidney disease (CKD) and diabetes mellitus (DM) remain strong clinical predictors of poor prognosis despite DES implantation. Sarpogrelate, a selective serotonin (5-hydroxytryptamine (HT)2a [5-HT2A]) receptor antagonist, has antiproliferative effects, reducing neointimal hyperplasia and smooth muscle cell proliferation, as well as potent antiplatelet action, inhibiting 5-HT-induced platelet aggregation. However, efficacy and safety data for sarpogrelate in patients with CKD or DM are limited. We aim to determine whether sarpogrelate has beneficial effects in patients with CDK or DM treated with DES implantation. The SERENADE trial is a multicenter, open-label, prospective, randomized study that will test the superiority of triple anti-platelet therapy (TAT; aspirin, clopidogrel, and sarpogrelate) to conventional dual antiplatelet therapy (DAT; aspirin and clopidogrel) in preventing late lumen loss 9 months after the index procedure in patients with CKD or DM. A total of 220 patients diagnosed with coronary artery disease with DM or CKD will be randomized to the TAT or DAT groups (1:1 ratio) after DES implantation. The primary endpoint is late lumen loss at 9 months assessed by quantitative coronary angiography. Secondary efficacy endpoints are composites of major adverse cardiovascular events including cardiac death, nonfatal myocardial infarction, and target lesion revascularization. Secondary safety endpoints are major bleeding events and hepatic or renal impairment. The SERENADE trial will provide insight on the efficacy of adjunctive therapy with sarpogrelate after DES implantation for patients with high-risk profiles such as CKD or DM. National Institutes of Health Clinical Trials Registry (ClinicalTrials.gov NCT02294643). Copyright © 2015. Published by Elsevier Inc.

  9. Cognitive Compensation of Speech Perception With Hearing Impairment, Cochlear Implants, and Aging : How and to What Degree Can It Be Achieved?

    NARCIS (Netherlands)

    Baskent, Deniz; Clarke, Jeanne; Pals, Carina; Benard, Michel R.; Bhargava, Pranesh; Saija, Jefta; Sarampalis, Anastasios; Wagner, Anita; Gaudrain, Etienne

    2016-01-01

    External degradations in incoming speech reduce understanding, and hearing impairment further compounds the problem. While cognitive mechanisms alleviate some of the difficulties, their effectiveness may change with age. In our research, reviewed here, we investigated cognitive compensation with

  10. Soluble CD163 levels are elevated in cerebrospinal fluid and serum in people with Type 2 diabetes mellitus and are associated with impaired peripheral nerve function

    DEFF Research Database (Denmark)

    Kallestrup, M; Møller, Holger Jon; Tankisi, H

    2015-01-01

    and serum in participants with neuropathy than in those without neuropathy [cerebrospinal fluid: median (range) 131 (86-173) vs 101 (70-190) μg/l, P = 0.08 and serum: 3725 (920-7060) vs 2220 (1130-4780), P = 0.06). CONCLUSIONS: Cerebrospinal fluid soluble CD163 level is associated with impaired peripheral......AIMS: To measure soluble CD163 levels in the cerebrospinal fluid and serum of people with Type 2 diabetes, with and without polyneuropathy, and to relate the findings to peripheral nerve function. METHODS: A total of 22 people with Type 2 diabetes and 12 control subjects without diabetes were...... included in this case-control study. Participants with diabetes were divided into those with neuropathy (n = 8) and those without neuropathy (n = 14) based on clinical examination, vibratory perception thresholds and nerve conduction studies. Serum and cerebrospinal fluid soluble CD163 levels were analysed...

  11. Elevated 1-h post-challenge plasma glucose levels in subjects with normal glucose tolerance or impaired glucose tolerance are associated with whole blood viscosity.

    Science.gov (United States)

    Marini, Maria Adelaide; Fiorentino, Teresa Vanessa; Andreozzi, Francesco; Mannino, Gaia Chiara; Perticone, Maria; Sciacqua, Angela; Perticone, Francesco; Sesti, Giorgio

    2017-08-01

    It has been suggested that glucose levels ≥155 mg/dl at 1-h during an oral glucose tolerance test (OGTT) may predict development of type 2 diabetes and cardiovascular events among adults with normal glucose tolerance (NGT 1 h-high). Studies showed a link between increased blood viscosity and type 2 diabetes. However, whether blood viscosity is associated with dysglycemic conditions such as NGT 1 h-high, impaired glucose tolerance (IGT) or impaired fasting glucose (IFG) is unsettled. 1723 non-diabetic adults underwent biochemical evaluation and OGTT. A validated formula based on hematocrit and total plasma proteins was employed to estimate whole blood viscosity. Subjects were categorized into NGT with 1 h glucose h-low), NGT-1 h-high, IFG and/or IGT. Hematocrit and blood viscosity values appeared significantly higher in individuals with NGT 1 h-high, IFG and/or IGT as compared to NGT 1 h-low subjects. Blood viscosity was significantly correlated with age, waist circumference, blood pressure, HbA1c, fasting, 1- and 2-h post-challenge insulin levels, total cholesterol and low-density lipoprotein, triglycerides, fibrinogen, white blood cell, and inversely correlated with high-density lipoprotein and insulin sensitivity. Of the four glycemic parameters, 1-h post-challenge glucose showed the strongest correlation with blood viscosity (β = 0.158, P h post-challenge plasma glucose. They also suggest that a subgroup of NGT individuals with 1-h post-challenge plasma >155 mg/dl have increased blood viscosity comparable to that observed in subjects with IFG and/or IGT.

  12. Elevated pulmonary arterial and systemic plasma aldosterone levels associate with impaired cardiac reserve capacity during exercise in left ventricular systolic heart failure patients: A pilot study.

    Science.gov (United States)

    Maron, Bradley A; Stephens, Thomas E; Farrell, Laurie A; Oldham, William M; Loscalzo, Joseph; Leopold, Jane A; Lewis, Gregory D

    2016-03-01

    Elevated levels of aldosterone are a modifiable contributor to clinical worsening in heart failure with reduced ejection fraction (HFrEF). Endothelin-1 (ET-1), which is increased in HFrEF, induces pulmonary endothelial aldosterone synthesis in vitro. However, whether transpulmonary aldosterone release occurs in humans or aldosterone relates to functional capacity in HFrEF is not known. Therefore, we aimed to characterize ET-1 and transpulmonary aldosterone levels in HFrEF and determine if aldosterone levels relate to peak volume of oxygen uptake (pVO2). Data from 42 consecutive HFrEF patients and 18 controls referred for invasive cardiopulmonary exercise testing were analyzed retrospectively. Radial ET-1 levels (median [interquartile range]) were higher in HFrEF patients compared with controls (17.5 [11.5-31.4] vs 11.5 [4.4-19.0] pg/ml, p = 0.04). A significant ET-1 transpulmonary gradient (pulmonary arterial [PA] - radial arterial levels) was present in HFrEF (p reserve capacity in HFrEF. Published by Elsevier Inc.

  13. Auditory Discrimination of Lexical Stress Patterns in Hearing-Impaired Infants with Cochlear Implants Compared with Normal Hearing: Influence of Acoustic Cues and Listening Experience to the Ambient Language.

    Science.gov (United States)

    Segal, Osnat; Houston, Derek; Kishon-Rabin, Liat

    2016-01-01

    To assess discrimination of lexical stress pattern in infants with cochlear implant (CI) compared with infants with normal hearing (NH). While criteria for cochlear implantation have expanded to infants as young as 6 months, little is known regarding infants' processing of suprasegmental-prosodic cues which are known to be important for the first stages of language acquisition. Lexical stress is an example of such a cue, which, in hearing infants, has been shown to assist in segmenting words from fluent speech and in distinguishing between words that differ only the stress pattern. To date, however, there are no data on the ability of infants with CIs to perceive lexical stress. Such information will provide insight to the speech characteristics that are available to these infants in their first steps of language acquisition. This is of particular interest given the known limitations that the CI device has in transmitting speech information that is mediated by changes in fundamental frequency. Two groups of infants participated in this study. The first group included 20 profoundly hearing-impaired infants with CI, 12 to 33 months old, implanted under the age of 2.5 years (median age of implantation = 14.5 months), with 1 to 6 months of CI use (mean = 2.7 months) and no known additional problems. The second group of infants included 48 NH infants, 11 to 14 months old with normal development and no known risk factors for developmental delays. Infants were tested on their ability to discriminate between nonsense words that differed on their stress pattern only (/dóti/ versus /dotí/ and /dotí/ versus /dóti/) using the visual habituation procedure. The measure for discrimination was the change in looking time between the last habituation trial (e.g., /dóti/) and the novel trial (e.g., /dotí/). (1) Infants with CI showed discrimination between lexical stress pattern with only limited auditory experience with their implant device, (2) discrimination of stress

  14. Two-stage implant systems.

    Science.gov (United States)

    Fritz, M E

    1999-06-01

    Since the advent of osseointegration approximately 20 years ago, there has been a great deal of scientific data developed on two-stage integrated implant systems. Although these implants were originally designed primarily for fixed prostheses in the mandibular arch, they have been used in partially dentate patients, in patients needing overdentures, and in single-tooth restorations. In addition, this implant system has been placed in extraction sites, in bone-grafted areas, and in maxillary sinus elevations. Often, the documentation of these procedures has lagged. In addition, most of the reports use survival criteria to describe results, often providing overly optimistic data. It can be said that the literature describes a true adhesion of the epithelium to the implant similar to adhesion to teeth, that two-stage implants appear to have direct contact somewhere between 50% and 70% of the implant surface, that the microbial flora of the two-stage implant system closely resembles that of the natural tooth, and that the microbiology of periodontitis appears to be closely related to peri-implantitis. In evaluations of the data from implant placement in all of the above-noted situations by means of meta-analysis, it appears that there is a strong case that two-stage dental implants are successful, usually showing a confidence interval of over 90%. It also appears that the mandibular implants are more successful than maxillary implants. Studies also show that overdenture therapy is valid, and that single-tooth implants and implants placed in partially dentate mouths have a success rate that is quite good, although not quite as high as in the fully edentulous dentition. It would also appear that the potential causes of failure in the two-stage dental implant systems are peri-implantitis, placement of implants in poor-quality bone, and improper loading of implants. There are now data addressing modifications of the implant surface to alter the percentage of

  15. Carbon implantation into tungsten at elevated temperatures

    International Nuclear Information System (INIS)

    Eckstein, W.; Shulga, V.I.; Roth, J.

    1999-01-01

    The bombardment of W with 2.4 keV C at normal incidence in the temperature range between 293 and 973 K is investigated experimentally and by computer simulation. At room temperature the measured weight is at first increasing but then changing to a weight gain with the incident C fluence. This weight gain is reduced at temperatures above 750 K, and at 973 K a constant weight loss is observed. The computing approach was to couple the dynamic Monte Carlo program TRIDYN with the diffusion program PIDAT. Input data for C diffusion in W are taken from the literature. Agreement between experimental data and computed results can be achieved at temperatures around 800 K by using a smaller diffusion coefficient in the simulations than those found in the literature

  16. Restoring the IL-1β/NF-κB-induced impaired chondrogenesis by diallyl disulfide in human adipose-derived mesenchymal stem cells via attenuation of reactive oxygen species and elevation of antioxidant enzymes.

    Science.gov (United States)

    Bahrampour Juybari, Kobra; Kamarul, Tunku; Najafi, Mohammad; Jafari, Davood; Sharifi, Ali Mohammad

    2018-03-26

    Strategies based on mesenchymal stem cell (MSC) therapy for restoring injured articular cartilage are not effective enough in osteoarthritis (OA). Due to the enhanced inflammation and oxidative stress in OA microenvironment, differentiation of MSCs into chondrocytes would be impaired. This study aims to explore the effects of diallyl disulfide (DADS) on IL-1β-mediated inflammation and oxidative stress in human adipose derived mesenchymal stem cells (hADSCs) during chondrogenesis. MTT assay was employed to examine the effects of various concentrations of DADS on the viability of hADSCs at different time scales to obtain non-cytotoxic concentration range of DADS. The effects of DADS on IL-1β-induced intracellular ROS generation and lipid peroxidation were evaluated in hADSCs. Western blotting was used to analyze the protein expression levels of IκBα (np), IκBα (p), NF-κB (np) and NF-κB (p). Furthermore, the gene expression levels of antioxidant enzymes in hADSCs and chondrogenic markers at days 7, 14 and 21 of differentiation were measured using qRT-PCR. The results showed that addition of DADS significantly enhanced the mRNA expression levels of antioxidant enzymes as well as reduced ROS elevation, lipid peroxidation, IκBα activation and NF-κB nuclear translocation in hADSCs treated with IL-1β. In addition, DADS could significantly increase the expression levels of IL-1β-induced impaired chondrogenic marker genes in differentiated hADSCs. Treatment with DADS may provide an effective approach to prevent the pro-inflammatory cytokines and oxidative stress as catabolic causes of chondrocyte cell death and enhance the protective anabolic effects by promoting chondrogenesis associated gene expressions in hADSCs exposed to OA condition.

  17. Cochlear Implants

    Science.gov (United States)

    ... implant, including: • How long a person has been deaf, •The number of surviving auditory nerve fibers, and • ... Implant, Severe Sensoryneurial Hearing Loss Get Involved Professional Development Practice Management ENT Careers Marketplace Privacy Policy Terms ...

  18. Critical Assessment of Implantable Drug Delivery Devices in Glaucoma Management

    Directory of Open Access Journals (Sweden)

    Dharani Manickavasagam

    2013-01-01

    Full Text Available Glaucoma is a group of heterogeneous disorders involving progressive optic neuropathy that can culminate into visual impairment and irreversible blindness. Effective therapeutic interventions must address underlying vulnerability of retinal ganglion cells (RGCs to degeneration in conjunction with correcting other associated risk factors (such as elevated intraocular pressure. However, realization of therapeutic outcomes is heavily dependent on suitable delivery system that can overcome myriads of anatomical and physiological barriers to intraocular drug delivery. Development of clinically viable sustained release systems in glaucoma is a widely recognized unmet need. In this regard, implantable delivery systems may relieve the burden of chronic drug administration while potentially ensuring high intraocular drug bioavailability. Presently there are no FDA-approved implantable drug delivery devices for glaucoma even though there are several ongoing clinical studies. The paper critically assessed the prospects of polymeric implantable delivery systems in glaucoma while identifying factors that can dictate (a patient tolerability and acceptance, (b drug stability and drug release profiles, (c therapeutic efficacy, and (d toxicity and biocompatibility. The information gathered could be useful in future research and development efforts on implantable delivery systems in glaucoma.

  19. Data Elevator

    Energy Technology Data Exchange (ETDEWEB)

    2017-04-29

    Data Elevator: Efficient Asynchronous Data Movement in Hierarchical Storage Systems Multi-layer storage subsystems, including SSD-based burst buffers and disk-based parallel file systems (PFS), are becoming part of HPC systems. However, software for this storage hierarchy is still in its infancy. Applications may have to explicitly move data among the storage layers. We propose Data Elevator for transparently and efficiently moving data between a burst buffer and a PFS. Users specify the final destination for their data, typically on PFS, Data Elevator intercepts the I/O calls, stages data on burst buffer, and then asynchronously transfers the data to their final destination in the background. This system allows extensive optimizations, such as overlapping read and write operations, choosing I/O modes, and aligning buffer boundaries. In tests with large-scale scientific applications, Data Elevator is as much as 4.2X faster than Cray DataWarp, the start-of-art software for burst buffer, and 4X faster than directly writing to PFS. The Data Elevator library uses HDF5's Virtual Object Layer (VOL) for intercepting parallel I/O calls that write data to PFS. The intercepted calls are redirected to the Data Elevator, which provides a handle to write the file in a faster and intermediate burst buffer system. Once the application finishes writing the data to the burst buffer, the Data Elevator job uses HDF5 to move the data to final destination in an asynchronous manner. Hence, using the Data Elevator library is currently useful for applications that call HDF5 for writing data files. Also, the Data Elevator depends on the HDF5 VOL functionality.

  20. An elevator

    Energy Technology Data Exchange (ETDEWEB)

    Loginovskiy, V.I.; Medinger, N.V.; Rasskazov, V.A.; Solonitsyn, V.A.

    1983-01-01

    An elevator is proposed which includes a body, spring loaded cams and a shut-off ring. To increase the reliability of the elevator by eliminating the possibility of spontaneous shifting of the shut-off ring, the latter is equipped with handles hinged to it and is made with evolvent grooves. The cams are equipped with rollers installed in the evolvent grooves of the shut off ring, where the body is made with grooves for the handles.

  1. Monocular Elevation Deficiency - Double Elevator Palsy

    Science.gov (United States)

    ... Español Condiciones Chinese Conditions Monocular Elevation Deficiency/ Double Elevator Palsy En Español Read in Chinese What is monocular elevation deficiency (Double Elevator Palsy)? Monocular Elevation Deficiency, also known by the ...

  2. Impaired CD4+ and T-helper 17 cell memory response to Streptococcus pneumoniae is associated with elevated glucose and percent glycated hemoglobin A1c in Mexican Americans with type 2 diabetes mellitus.

    Science.gov (United States)

    Martinez, Perla J; Mathews, Christine; Actor, Jeffrey K; Hwang, Shen-An; Brown, Eric L; De Santiago, Heather K; Fisher Hoch, Susan P; McCormick, Joseph B; Mirza, Shaper

    2014-01-01

    Individuals with type 2 diabetes are significantly more susceptible to pneumococcal infections than healthy individuals of the same age. Increased susceptibility is the result of impairments in both innate and adaptive immune systems. Given the central role of T-helper 17 (Th17) and T-regulatory (Treg) cells in pneumococcal infection and their altered phenotype in diabetes, this study was designed to analyze the Th17 and Treg cell responses to a whole heat-killed capsular type 2 strain of Streptococcus pneumoniae. Patients with diabetes demonstrated a lower frequency of total CD+T-cells, which showed a significant inverse association with elevated fasting blood glucose. Measurement of specific subsets indicated that those with diabetes had, low intracellular levels of interleukin (IL)-17, and lower pathogen-specific memory CD4+ and IL-17+ cell numbers. No significant difference was observed in the frequency of CD4+ and Th17 cells between those with and without diabetes. However, stratification of data by obesity indicated a significant increase in frequency of CD4+ and Th17 cells in obese individuals with diabetes compared with nonobese individual with diabetes. The memory CD+T-cell response was associated inversely with both fasting blood glucose and percent glycated hemoglobin A1c. This study demonstrated that those with type 2 diabetes have a diminished pathogen-specific memory CD4+ and Th17 response, and low percentages of CD+T-cells in response to S. pneumoniae stimulation. Copyright © 2014 Mosby, Inc. All rights reserved.

  3. Ion implantation

    International Nuclear Information System (INIS)

    Johnson, E.

    1986-01-01

    It is the purpose of the present paper to give a review of surface alloy processing by ion implantation. However, rather than covering this vast subject as a whole, the survey is confined to a presentation of the microstructures that can be found in metal surfaces after ion implantation. The presentation is limited to alloys processed by ion implantation proper, that is to processes in which the alloy compositions are altered significantly by direct injection of the implanted ions. The review is introduced by a presentation of the processes taking place during development of the fundamental event in ion implantation - the collision cascade, followed by a summary of the various microstructures which can be formed after ion implantation into metals. This is compared with the variability of microstructures that can be achieved by rapid solidification processing. The microstructures are subsequently discussed in the light of the processes which, as the implantations proceed, take place during and immediately after formation of the individual collision cascades. These collision cascades define the volumes inside which individual ions are slowed down in the implanted targets. They are not only centres for vigorous agitation but also the sources for formation of excess concentrations of point defects, which will influence development of particular microstructures. A final section presents a selection of specific structures which have been observed in different alloy systems. (orig./GSCH)

  4. Elevator wheel

    Energy Technology Data Exchange (ETDEWEB)

    Zhornik, V.I.; Cherkov, Ye.M.; Simonov, A.A.

    1982-01-01

    An elevator wheel is suggested for unloading a sunken product from a bath of a heavy-average separator including discs of a bucket with inner walls, and covering sheets hinged to the buckets. In order to improve the degree of dehydration of the removed product, the inner wall of each bucket is made of sheets installed in steps with gaps of one in relation to the other.

  5. Implantation in assisted reproduction: a look at endometrial receptivity.

    Science.gov (United States)

    Fatemi, H M; Popovic-Todorovic, B

    2013-11-01

    Implantation failure in assisted reproduction is thought to be mainly due to impaired uterine receptivity. With normal uterine anatomy, changes in endocrine profile during ovarian stimulation and medical conditions of the mother (i.e. thrombophilia and abnormal immunological response) could result in a non-receptive endometrium. High oestradiol concentrations during ovarian stimulation lead to premature progesterone elevation, causing endometrial advancement and hampering implantation, which can be overcome by a freeze-all approach and embryo transfer in natural cycles or by milder stimulation protocols. Patients with recurrent implantation failure (RIF) should be tested for inherited and acquired thrombophilias. Each patient should be individually assessed and counselled regarding therapy with low-molecular-weight heparin (LMWH). Empirical treatment with LMWH, aspirin or corticosteroids is not effective for women with RIF who have negative thrombophilic tests. If thrombophilic tests are normal, patients should be tested for immunological causes. If human leukocyte antigen dissimilarity is proven, treatment with intravenous immunoglobulin might be beneficial. Preliminary observational studies using intralipid infusion in the presence of increased natural killer cytotoxic activity are interesting but the proposed rationale is controversial and randomized controlled trials are needed. Hysteroscopy and/or endometrial scratching in the cycle preceding ovarian stimulation should become standard for patients with RIF. Copyright © 2013 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  6. Piezosurgery in implant dentistry

    Science.gov (United States)

    Stübinger, Stefan; Stricker, Andres; Berg, Britt-Isabelle

    2015-01-01

    Piezosurgery, or the use of piezoelectric devices, is being applied increasingly in oral and maxillofacial surgery. The main advantages of this technique are precise and selective cuttings, the avoidance of thermal damage, and the preservation of soft-tissue structures. Through the application of piezoelectric surgery, implant-site preparation, bone grafting, sinus-floor elevation, edentulous ridge splitting or the lateralization of the inferior alveolar nerve are very technically feasible. This clinical overview gives a short summary of the current literature and outlines the advantages and disadvantages of piezoelectric bone surgery in implant dentistry. Overall, piezoelectric surgery is superior to other methods that utilize mechanical instruments. Handling of delicate or compromised hard- and soft-tissue conditions can be performed with less risk for the patient. With respect to current and future innovative surgical concepts, piezoelectric surgery offers a wide range of new possibilities to perform customized and minimally invasive osteotomies. PMID:26635486

  7. An elevator

    Energy Technology Data Exchange (ETDEWEB)

    Gusev, A.S.; Peshkov, L.P.; Rozin, M.M.; Shestov, A.G.

    1983-01-01

    An elevator is proposed which includes a body, a flap, a lock with a catch and a spring-loaded shut-off clamp in the form of upper and lower horizontal levers which are connected by a handle and an axle and one end of which is made in the form of an eccentric cam. The size of the eccentricity of the cam of the levers is increased toward the handle of the clamp in order to increase the operational reliability and to extend the service life.

  8. An elevator

    Energy Technology Data Exchange (ETDEWEB)

    Rastorguyev, M.A.; Maloyarovslavtesv, D.A.; Prokopov, O.I.; Tukayev, Sh.V.; Zanilov, I.F.

    1983-01-01

    An elevator is proposed which includes a body with a turning collar locking device and a rod with longitudinal grooves, which are flexibly linked with jaws positioned in grooves in the body. To increase safety through ensuring automatic locking of the jaws in the closed position, the locking device is made in the form of head on wedges, spring loaded relative to the collar and made with cams and positioned with the capability of interacting with the grooves of the rod and through the cams with the collar.

  9. Carmustine Implant

    Science.gov (United States)

    ... works by slowing or stopping the growth of cancer cells in your body. ... are pregnant, plan to become pregnant, or are breast-feeding. If you become pregnant while receiving carmustine implant, call your doctor. Carmustine may harm the fetus.

  10. Cochlear Implants

    Science.gov (United States)

    ... NIDCD A cochlear implant is a small, complex electronic device that can help to provide a sense ... Hearing Aids Retinitis Pigmentosa - National Eye Institute Telecommunications Relay Services Usher Syndrome Your Baby's Hearing Screening News ...

  11. Bucket elevator

    OpenAIRE

    Chromek, Jiří

    2013-01-01

    Cílem této bakalářské práce je návrh svislého korečkového elevátoru, který má sloužit k dopravě obilovin s dopravní výškou 19 m a dopravovaným množstvím 100 t/hod. Práce se skládá z popisu korečkového elevátoru a jeho hlavních částí, zmiňující se v úvodní rešerši. Tato práce je zaměřena na funkční a kapacitní výpočet, určení pohonu a napínacího zařízení. Další výpočet je kontrolní, skládající se z pevnostní kontroly hnacího hřídele, výpočtu pera, životnosti ložisek a výpočtu napínacího zaříze...

  12. Implantation, recoil implantation, and sputtering

    International Nuclear Information System (INIS)

    Kelly, R.

    1984-01-01

    The implantation and sputtering mechanisms which are relevant to ion bombardment of surfaces are described. These are: collision, thermal, electronic and photon-induced sputtering. 135 refs.; 36 figs.; 9 tabs

  13. Basic research on maxillofacial implants

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, Yoshiro [Showa Univ., Tokyo (Japan). School of Dentistry

    2001-11-01

    Osseointegrated implants have begun to be used not only in general practice in dentistry but also in various clinical situations in the maxillofacial region. The process has yielded three problems: the spread of application, new materials and diagnostic methods, and management for difficult situations. This paper presents basic data and clinical guidelines for new applications, it investigates the characteristics of the materials and the usefulness of a new diagnostic method, and it studies effective techniques for difficult cases. The results obtained are as follows: Investigations into the spreading application. The lateral and superior orbital rim have sufficient bone thickness and width for the implant body to be placed. Osseointegrated implants, especially by the fixed bridge technique, are not recommended in the craniofacial bone and jaws of young children. Implant placement into bone after/before irradiation must be performed in consideration of impaired osteogenesis, the decrease of trabecular bone, and the time interval between implantation and irradiation. Investigations into materials and diagnostic methods. Hydroxyapatite-coated and titanium implants should be selected according to the characteristics of the materials. A dental simulating soft may also be applicable in the craniofacial region. Investigations into the management of difficult cases. Hyperbaric oxygen therapy (HBO), bone morphogenetic protein (BMP), and tissue engineering should be useful for improving the quality and increasing the quantity of bone where implants are placed. Soft tissue around implants placed in the reconstructed area should be replaced with mucosal tissue. The data obtained here should be useful for increasing the efficiency of osseointegrated implants, but further basic research is required in the future. (author)

  14. Basic research on maxillofacial implants

    International Nuclear Information System (INIS)

    Matsui, Yoshiro

    2001-01-01

    Osseointegrated implants have begun to be used not only in general practice in dentistry but also in various clinical situations in the maxillofacial region. The process has yielded three problems: the spread of application, new materials and diagnostic methods, and management for difficult situations. This paper presents basic data and clinical guidelines for new applications, it investigates the characteristics of the materials and the usefulness of a new diagnostic method, and it studies effective techniques for difficult cases. The results obtained are as follows: Investigations into the spreading application. The lateral and superior orbital rim have sufficient bone thickness and width for the implant body to be placed. Osseointegrated implants, especially by the fixed bridge technique, are not recommended in the craniofacial bone and jaws of young children. Implant placement into bone after/before irradiation must be performed in consideration of impaired osteogenesis, the decrease of trabecular bone, and the time interval between implantation and irradiation. Investigations into materials and diagnostic methods. Hydroxyapatite-coated and titanium implants should be selected according to the characteristics of the materials. A dental simulating soft may also be applicable in the craniofacial region. Investigations into the management of difficult cases. Hyperbaric oxygen therapy (HBO), bone morphogenetic protein (BMP), and tissue engineering should be useful for improving the quality and increasing the quantity of bone where implants are placed. Soft tissue around implants placed in the reconstructed area should be replaced with mucosal tissue. The data obtained here should be useful for increasing the efficiency of osseointegrated implants, but further basic research is required in the future. (author)

  15. Surface modifications of dental implants.

    Science.gov (United States)

    Stanford, C M

    2008-06-01

    Dental implant surface technologies have been evolving rapidly to enhance a more rapid bone formation on their surface and hold a potential to increase the predictability of expedited implant therapy. While implant outcomes have become highly predictable, there are sites and conditions that result in elevated implant loss. This paper reviews the impact of macro-retentive features which includes approaches to surface oxide modification, thread design, press-fit and sintered-bead technologies to increase predictability of outcomes. Implant designs that lead to controlled lateral compression of the bone can improve primary stability as long as the stress does not exceed the localized yield strength of the cortical bone. Some implant designs have reduced crestal bone loss by use of multiple cutting threads that are closely spaced, smoothed on the tip but designed to create a hoop-stress stability of the implant as it is completely seated in the osteotomy. Following the placement of the implant, there is a predictable sequence of bone turnover and replacement at the interface that allows the newly formed bone to adapt to microscopic roughness on the implant surface, and on some surfaces, a nanotopography (<10(-9) m scale) that has been shown to preferably influence the formation of bone. Newly emerging studies show that bone cells are exquisitely sensitive to these topographical features and will upregulate the expression of bone related genes for new bone formation when grown on these surfaces. We live in an exciting time of rapid changes in the modalities we can offer patients for tooth replacement therapy. Given this, it is our responsibility to be critical when claims are made, incorporate into our practice what is proven and worthwhile, and to continue to support and provide the best patient care possible.

  16. A lateral approach for sinus elevation using PRGF technology.

    Science.gov (United States)

    Anitua, Eduardo; Prado, Roberto; Orive, Gorka

    2009-10-01

    A lateral approach for sinus elevation using plasma rich in growth factors (PRGF) technology is described. The long-term survival of dental implants installed following a two-stage procedure after sinus elevation using this procedure is reported, using implant loss as the outcome variable. A retrospective cohort study design was used. Eighteen patients received 43 implants (BTI implants, Biotechnology Institute, Vitoria, Spain) with sinus floor elevation. All patients presented a residual bone height of class D (1-3 mm). Implants were installed using a low-speed drilling procedure (50 rpm) without irrigation. Finally, the histological and histomorphometric evaluation of eight samples from PRGF grafted sinus involved in the study was carried out 5-6 months posttreatment. The overall survival rate of dental implants was 100%. The mean follow-up period for all implants was 33 +/- 7 months ranging from 24 to 44 months. In addition, the histomorphometrical evaluation of the samples evidenced a 25.24 +/- 4.62% of vital newly formed bone, 50.31 +/- 15.56% of soft connective tissue, and the remaining 24.46 +/- 12.79% of bovine anorganic bone. Based on these results, this new approach for sinus elevation and implant installation using PRGF technology can be considered safe, simple, effective, and predictable.

  17. Hip Implant Systems

    Science.gov (United States)

    ... Implants and Prosthetics Metal-on-Metal Hip Implants Hip Implants Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Hip implants are medical devices intended to restore mobility ...

  18. Breast reconstruction - implants

    Science.gov (United States)

    Breast implants surgery; Mastectomy - breast reconstruction with implants; Breast cancer - breast reconstruction with implants ... harder to find a tumor if your breast cancer comes back. Getting breast implants does not take as long as breast reconstruction ...

  19. RBS studies of the lattice damage caused by 1 MeV Si+ implantation into Al0.3Ga0.7As/GaAs superlattices at elevated temperature

    International Nuclear Information System (INIS)

    Xu Tianbing; Zhu Peiran; Zhou Junsi; Li Daiqing; Gong Baoan; Wan Ya; Mu Shanming; Zhao Qingtai; Wang Zhonglie

    1994-01-01

    The lattice damage accumulation in GaAs and Al 0.3 Ga 0.7 As/GaAs superlattices by 1 MeV Si + irradiation at room temperature and 350 C has been studied. For irradiations at 350 C, at lower doses the samples were almost defect-free after irradiation, while a large density of accumulated defects was induced at a higher dose. The critical dose above which the damage accumulation is more efficient is estimated to be 2 x 10 15 Si/cm 2 for GaAs, and is 5 x 10 15 Si/cm 2 for Al 0.8 Ga 0.7 As/GaAs superlattice for implantation with 1.0 MeV Si ions at 350 C. The damage accumulation rate for 1 MeV Si ion implantation in Al 0.3 Ga 0.7 As/GaAs superlattice is less than that in GaAs. (orig.)

  20. Piezosurgery in implant dentistry

    Directory of Open Access Journals (Sweden)

    Stübinger S

    2015-11-01

    Full Text Available Stefan Stübinger,1 Andres Stricker,2 Britt-Isabelle Berg3,4 1Hightech Research Center of Cranio-maxillofacial Surgery, University of Basel, Allschwil, Switzerland; 2Private Practice, Konstanz, Germany; 3Department of Cranio-maxillofacial Surgery, University Hospital Basel, Basel, Switzerland; 4Division of Oral and Maxillofacial Radiology, Columbia University Medical Center, New York, NY, USA Abstract: Piezosurgery, or the use of piezoelectric devices, is being applied increasingly in oral and maxillofacial surgery. The main advantages of this technique are precise and selective cuttings, the avoidance of thermal damage, and the preservation of soft-tissue structures. Through the application of piezoelectric surgery, implant-site preparation, bone grafting, sinus-floor elevation, edentulous ridge splitting or the lateralization of the inferior alveolar nerve are very technically feasible. This clinical overview gives a short summary of the current literature and outlines the advantages and disadvantages of piezoelectric bone surgery in implant dentistry. Overall, piezoelectric surgery is superior to other methods that utilize mechanical instruments. Handling of delicate or compromised hard- and soft-tissue conditions can be performed with less risk for the patient. With respect to current and future innovative surgical concepts, piezoelectric surgery offers a wide range of new possibilities to perform customized and minimally invasive osteotomies. Keywords: implantology, piezoelectric device, piezosurgery, maxillary sinus elevation, bone grafting, osteotomy, edentulous ridge splitting

  1. Tinnitus and Sleep Difficulties After Cochlear Implantation.

    Science.gov (United States)

    Pierzycki, Robert H; Edmondson-Jones, Mark; Dawes, Piers; Munro, Kevin J; Moore, David R; Kitterick, Pádraig T

    To estimate and compare the prevalence of and associations between tinnitus and sleep difficulties in a sample of UK adult cochlear implant users and those identified as potential candidates for cochlear implantation. The study was conducted using the UK Biobank resource, a population-based cohort of 40- to 69-year olds. Self-report data on hearing, tinnitus, sleep difficulties, and demographic variables were collected from cochlear implant users (n = 194) and individuals identified as potential candidates for cochlear implantation (n = 211). These "candidates" were selected based on (i) impaired hearing sensitivity, inferred from self-reported hearing aid use and (ii) impaired hearing function, inferred from an inability to report words accurately at negative signal to noise ratios on an unaided closed-set test of speech perception. Data on tinnitus (presence, persistence, and related distress) and on sleep difficulties were analyzed using logistic regression models controlling for gender, age, deprivation, and neuroticism. The prevalence of tinnitus was similar among implant users (50%) and candidates (52%; p = 0.39). However, implant users were less likely to report that their tinnitus was distressing at its worst (41%) compared with candidates (63%; p = 0.02). The logistic regression model suggested that this difference between the two groups could be explained by the fact that tinnitus was less persistent in implant users (46%) compared with candidates (72%; p reported difficulties with sleep were similar among implant users (75%) and candidates (82%; p = 0.28), but participants with tinnitus were more likely to report sleep difficulties than those without (p explanation is supported by the similar prevalence of sleep problems among implant users and potential candidates for cochlear implantation, despite differences between the groups in tinnitus persistence and related emotional distress. Cochlear implantation may therefore not be an appropriate intervention

  2. Systematic review: Radiological and histological evidence of cochlear implant insertion trauma in adult patients.

    Science.gov (United States)

    Hoskison, Emma; Mitchell, Scott; Coulson, Chris

    2017-07-01

    Cochlear implantation (CI) has developed from its origins in the 1980s. Initially, CI was for profound bilateral hearing impairment. However, candidacy for CI have become more widespread in recent years with unilateral implantation and an emphasis on hearing preservation. Evidence supports full electrode insertion in an atraumatic fashion into the scala tympani (ST) provides optimal hearing outcomes. The main aim of this systematic review was to elucidate the degree of trauma associated with CI insertion. A systematic literature search was undertaken using PubMed Medline. A grading system described by Eshraghi was used to classify cochlear trauma. Both radiological and histological studies were included. Twenty one papers were identified which were relevant to our search. In total, 653 implants were inserted and 115 (17.6%) showed evidence of trauma. The cochleas with trauma had basilar membrane elevation in 5.2%, ruptured in 5.2%, the electrode passed from the ST to the SV in 84.4% and there was grade 4 trauma in 5.2%. The studies used a variety of histological and radiological methods to assess for evidence of trauma in both cadaveric temporal bones and live recipients. Minimizing cochlear trauma during implant insertion is important to preserve residual hearing and optimize audiological performance. An overall 17.6% trauma rate suggests that CI insertion could be improved with more accurate and consistent electrode insertion such as in the form of robotic guidance. The correlation of cochlea trauma with post-operative hearing has yet to be determined.

  3. [Cochlear implant treatment in Germany].

    Science.gov (United States)

    Jacob, R; Stelzig, Y

    2013-01-01

    Restoration of impaired auditory function through cochlear implant is possible, with high reliably and great success. Nevertheless, there are regular disputes between patients and insurance companies due to high costs. In Germany, approx. 1.9 Mio. people are severely hearing impaired. It can be estimated that for adequate hearing rehabilitation about 30,000 cochlear implants/year are necessary. Currently, less than 10% of those affected are offered cochlear implant. A handicap is defined if there is deviation from normal hearing for more than 6 months. This sets a time frame for the supply with cochlear implant after sudden deafness. The professional code requires to advice all medical options to a person seeking help for hearing loss. This includes benefit-risk consideration. At this point, the economic aspect plays no role. The indication for medical treatment is only subject to the treating physician and should not be modified by non-physicians or organizations. It should be noted that a supply of hearing aids is qualitatively different to the help from a cochlear implant, which provides a restoration of lost function. In social law (SGB V and IX) doctors are requested to advise and recommend all measures which contribute to normal hearing (both sides). This indicates that doctors may be prosecuted for not offering help when medically possible, just because health insurance employees did not approve the cost balance. The current situation, with insufficient medical care for the hearing impaired, needs clarifying. To do this, patients, health insurance companies, the political institutions, legislation and professional societies need to accept their responsibilities.

  4. Importance of cochlear health for implant function.

    Science.gov (United States)

    Pfingst, Bryan E; Zhou, Ning; Colesa, Deborah J; Watts, Melissa M; Strahl, Stefan B; Garadat, Soha N; Schvartz-Leyzac, Kara C; Budenz, Cameron L; Raphael, Yehoash; Zwolan, Teresa A

    2015-04-01

    Amazing progress has been made in providing useful hearing to hearing-impaired individuals using cochlear implants, but challenges remain. One such challenge is understanding the effects of partial degeneration of the auditory nerve, the target of cochlear implant stimulation. Here we review studies from our human and animal laboratories aimed at characterizing the health of the implanted cochlea and the auditory nerve. We use the data on cochlear and neural health to guide rehabilitation strategies. The data also motivate the development of tissue-engineering procedures to preserve or build a healthy cochlea and improve performance obtained by cochlear implant recipients or eventually replace the need for a cochlear implant. This article is part of a Special Issue entitled . Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Cochlear implant users' spectral ripple resolution.

    Science.gov (United States)

    Jeon, Eun Kyung; Turner, Christopher W; Karsten, Sue A; Henry, Belinda A; Gantz, Bruce J

    2015-10-01

    This study revisits the issue of the spectral ripple resolution abilities of cochlear implant (CI) users. The spectral ripple resolution of recently implanted CI recipients (implanted during the last 10 years) were compared to those of CI recipients implanted 15 to 20 years ago, as well as those of normal-hearing and hearing-impaired listeners from previously published data from Henry, Turner, and Behrens [J. Acoust. Soc. Am. 118, 1111-1121 (2005)]. More recently, implanted CI recipients showed significantly better spectral ripple resolution. There is no significant difference in spectral ripple resolution for these recently implanted subjects compared to hearing-impaired (acoustic) listeners. The more recently implanted CI users had significantly better pre-operative speech perception than previously reported CI users. These better pre-operative speech perception scores in CI users from the current study may be related to better performance on the spectral ripple discrimination task; however, other possible factors such as improvements in internal and external devices cannot be excluded.

  6. Cochlear implant: Speech and language development in deaf and hard of hearing children following implantation

    Directory of Open Access Journals (Sweden)

    Ostojić Sanja

    2011-01-01

    Full Text Available Bacground/Aim. Almost 200 cochlear implantations were done in the four centers (two in Belgrade, per one in Novi Sad and Niš in Serbia from 2002 to 2009. Less than 10% of implantees were postlingually deaf adults. The vast majority, i.e. 90% were pre- and perilingually profoundly deaf children. The aim of this study was to assess the influence of improved auditory perception due to cochlear implantation on comprehension of abstract words in children as compared with hearing impaired children with conventional hearing aids and normal hearing children. Methods. Thirty children were enrolled in this study: 20 hearing impaired and 10 normal hearing. The vocabulary test was used. Results. The overall results for the whole test (100 words showed a significant difference in favor of the normal hearing as compared with hearing impaired children. The normal hearing children successfully described or defined 77.93% of a total of 100 words. Success rate for the cochlear implanted children was 26.87% and for the hearing impaired children with conventional hearing aids 20.32%. Conclusion. Testing for abstract words showed a statistically significant difference between the cochlear implanted and the hearing impaired children with hearing aids (Mann- Whitney U-test, p = 0.019 implying considerable advantage of cochlear implants over hearing aids regarding successful speech development in prelingually deaf children.

  7. Short Implants: New Horizon in Implant Dentistry.

    Science.gov (United States)

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  8. Visual Impairment

    Science.gov (United States)

    ... site Sitio para adolescentes Body Mind Sexual Health Food & Fitness Diseases & Conditions Infections Drugs & Alcohol School & Jobs Sports Expert Answers (Q&A) Staying Safe Videos for Educators Search English Español Visual Impairment KidsHealth / For Teens / Visual Impairment What's in ...

  9. Are parents of children with cochlear implants coping?: research ...

    African Journals Online (AJOL)

    Many variables must be considered during the evaluation and rehabilitation of children for cochlear implantation, one of which is parental influence (for the duration of this report the parents, caregivers and guardians of children with cochlear implants and / or hearing impairments will be referred to as 'parents'). The aim of ...

  10. Implantation, recoil implantation, and sputtering

    International Nuclear Information System (INIS)

    Kelly, R.

    1984-01-01

    Underlying ion-beam modification of surfaces is the more basic subject of particle-surface interaction. The ideas can be grouped into forward and backward features, i.e. those affecting the interior of the target and those leading to particle expulsion. Forward effects include the stopping of the incident particles and the deposition of energy, both governed by integral equations which are easily set up but difficult to solve. Closely related is recoil implantation where emphasis is placed not on the stopping of the incident particles but on their interaction with target atoms with resulting implantation of these atoms. Backward effects, all of which are denoted as sputtering, are in general either of collisional, thermal, electronic, or exfoliational origin. (Auth.)

  11. Neurotrophic treatment of the degenerating auditory nerve; cochlear implants in deafened guinea pigs

    NARCIS (Netherlands)

    Agterberg, M.J.H.

    2009-01-01

    To date, the cochlear implant is the most successful sensorineural prosthesis. The device consists of a small array with a number of electrodes implanted in the cochlea of profoundly hearing impaired people. Some people with an implant are able to use the telephone. Unfortunately, others hardly

  12. Intra-operative defibrillation testing and clinical shock efficacy in patients with implantable cardioverter-defibrillators

    DEFF Research Database (Denmark)

    Bänsch, Dietmar; Bonnemeier, Hendrik; Brandt, Johan

    2015-01-01

    AIMS: This trial was designed to test the hypothesis that shock efficacy during follow-up is not impaired in patients implanted without defibrillation (DF) testing during first implantable cardioverter-defibrillator (ICD) implantation. METHODS AND RESULTS: Between February 2011 and July 2013, 107...

  13. Dental Implant Surgery

    Science.gov (United States)

    ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, ... to find out more. Wisdom Teeth Management Wisdom Teeth Management An impacted wisdom tooth can damage neighboring ...

  14. Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Mehrnaz Karimi

    1992-04-01

    Full Text Available People with profound hearing loss are not able to use some kinds of conventional amplifiers due to the nature of their loss . In these people, hearing sense is stimulated only when the auditory nerve is activated via electrical stimulation. This stimulation is possible through cochlear implant. In fact, for the deaf people who have good mental health and can not use surgical and medical treatment and also can not benefit from air and bone conduction hearing aids, this device is used if they have normal central auditory system. The basic parts of the device included: Microphone, speech processor, transmitter, stimulator and receiver, and electrode array.

  15. National Elevation Dataset (NED)

    Data.gov (United States)

    Kansas Data Access and Support Center — The U.S. Geological Survey has developed a National Elevation Database (NED). The NED is a seamless mosaic of best-available elevation data. The 7.5-minute elevation...

  16. Elevated Liver Enzymes

    Science.gov (United States)

    Symptoms Elevated liver enzymes By Mayo Clinic Staff Elevated liver enzymes may indicate inflammation or damage to cells in the liver. Inflamed or ... than normal amounts of certain chemicals, including liver enzymes, into the bloodstream, which can result in elevated ...

  17. Elevated 1-hour postload plasma glucose levels identify subjects with normal glucose tolerance but impaired β-cell function, insulin resistance, and worse cardiovascular risk profile: the GENFIEV study.

    Science.gov (United States)

    Bianchi, Cristina; Miccoli, Roberto; Trombetta, Maddalena; Giorgino, Francesco; Frontoni, Simona; Faloia, Emanuela; Marchesini, Giulio; Dolci, Maria A; Cavalot, Franco; Cavallo, Gisella; Leonetti, Frida; Bonadonna, Riccardo C; Del Prato, Stefano

    2013-05-01

    In subjects with normal glucose tolerance (NGT) 1-hour postload plasma glucose (1-h oral glucose tolerance test [OGTT]) of >155 mg/dL predicts type 2 diabetes (T2DM) and is associated with subclinical atherosclerosis. The purpose of this study was to evaluate β-cell function, insulin resistance, and cardiovascular risk profile in subjects with NGT with a 1-h OGTT glucose of >155 mg/dL. The GENFIEV (Genetics, PHYsiopathology, and Evolution of Type 2 diabetes) study is a multicenter study recruiting individuals at high risk of T2DM. A total of 926 subjects underwent a 75-g OGTT for assessment of plasma glucose and C-peptide for mathematical modeling of β-cell function (derivative and proportional control). Fasting insulin, lipid profile, and clinical parameters were determined as well. A 1-hour OGTT glucose of >155 mg/dL was found in 39% of subjects with NGT, 76% with impaired fasting glucose (IFG), 90% with impaired glucose tolerance (IGT), and 99% and 98% with IFG + IGT or newly diagnosed T2DM, respectively. Among subjects with NGT (n = 474), those with 1-hour OGTT glucose of >155 mg/dL were more insulin-resistant and had worse β-cell function than those with 1-hour OGTT glucose of ≤155 mg/dL. Moreover, glycosylated hemoglobin, blood pressure, low-density lipoprotein cholesterol, and triglycerides were higher in subjects with NGT with 1-hour OGTT glucose of >155 mg/dL, whereas high-density lipoprotein cholesterol was lower compared with that in subjects with NGT with 1-hour OGTT glucose of ≤155 mg/dL. Compared with subjects with IGT, those with NGT with 1-hour OGTT glucose of >155 mg/dL had comparable cardiovascular risk profile and insulin resistance but slightly better β-cell function. Among subjects with NGT, those with 1-hour OGTT glucose of >155 mg/dL showed lower insulin sensitivity, impaired β-cell function, and worse cardiovascular risk profile and therefore are at greater risk of developing T2DM and cardiovascular disease.

  18. Ion implantation as an efficient surface treatment

    International Nuclear Information System (INIS)

    Straede, C.A.

    1992-01-01

    Ion beam processing has for several years been well established in the semiconductor industry. In recent years ion implantation of tool steels, ceramics and even plastics has gained increasing industrial awareness. The development of ion implantation to a commercially viable surface treatment of tools and spare parts working in production type environments is very dependent on technical merits, economic considerations, competing processes and highly individual barriers to acceptance for each particular application. Some examples of this will be discussed. The development of the process is very closely linked with the development of high current accelerators and their ability to efficiently manipulate the samples being treated, or to make sample manipulation superfluous by using special beam systems like the PSII. Furthermore, the ability to produce high beam currents (mA) of a wide variety of ions is crucial. Previously, it was broadly accepted that ion implantation of tools on a commercial basis generally had to be limited to nitrogen implantation. The development of implanters which can produce high beam currents of ions like B + , C + , Ti + , Cr + and others is rapidly changing this situation, and today an increasing number of commercial implantations are performed with these ions although nitrogen is still successfully used in the majority of commercial implantation. All in all, the recent development of equipment makes it possible to a higher extent than before to tailor the implantation to a specific situation. The emerging new possibilities in this direction will be discussed, and a broad selection of practical examples of ion implantation at standard low temperatures of tools and spare parts will be given. Furthermore, very interesting results have been obtained recently by implanting nitrogen at elevated temperatures, which yields a relatively deep penetration of the implanted ions. (orig./WL)

  19. Impaired Driving

    Science.gov (United States)

    ... Get the Facts What Works: Strategies to Increase Car Seat and Booster Seat ... narcotics. 3 That’s one percent of the 111 million self-reported episodes of alcohol-impaired driving among U.S. ...

  20. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard

    2013-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  1. THE IMPLANT INFECTION PARADOX : WHY DO SOME SUCCEED WHEN OTHERS FAIL? OPINION AND DISCUSSION PAPER

    NARCIS (Netherlands)

    Yue, C.; Zhao, Bingran; Ren, Y.; Kuijer, R.; van der Mei, H. C.; Busscher, H. J.; Rochford, E. T. J.

    2015-01-01

    Biomaterial-implants are frequently used to restore function and form of human anatomy. However, the presence of implanted biomaterials dramatically elevates infection risk. Paradoxically, dental-implants placed in a bacteria-laden milieu experience moderate failure-rates, due to infection (0.0-1.1

  2. Syngeneic B16F10 Melanoma Causes Cachexia and Impaired Skeletal Muscle Strength and Locomotor Activity in Mice

    Directory of Open Access Journals (Sweden)

    Fabrício A. Voltarelli

    2017-09-01

    Full Text Available Muscle wasting has been emerging as one of the principal components of cancer cachexia, leading to progressive impairment of work capacity. Despite early stages melanomas rarely promotes weight loss, the appearance of metastatic and/or solid tumor melanoma can leads to cachexia development. Here, we investigated the B16F10 tumor-induced cachexia and its contribution to muscle strength and locomotor-like activity impairment. C57BL/6 mice were subcutaneously injected with 5 × 104 B16F10 melanoma cells or PBS as a Sham negative control. Tumor growth was monitored during a period of 28 days. Compared to Sham mice, tumor group depicts a loss of skeletal muscle, as well as significantly reduced muscle grip strength and epididymal fat mass. This data are in agreement with mild to severe catabolic host response promoted by elevated serum tumor necrosis factor-alpha (TNF-α, interleukin-6 (IL-6 and lactate dehydrogenase (LDH activity. Tumor implantation has also compromised general locomotor activity and decreased exploratory behavior. Likewise, muscle loss, and elevated inflammatory interleukin were associated to muscle strength loss and locomotor activity impairment. In conclusion, our data demonstrated that subcutaneous B16F10 melanoma tumor-driven catabolic state in response to a pro-inflammatory environment that is associated with impaired skeletal muscle strength and decreased locomotor activity in tumor-bearing mice.

  3. Pain from Dental Implant Placement, Inflammatory Pulpitis Pain, and Neuropathic Pain Present Different Somatosensory Profiles.

    Science.gov (United States)

    Porporatti, André Luís; Bonjardim, Leonardo Rigoldi; Stuginski-Barbosa, Juliana; Bonfante, Estevam Augusto; Costa, Yuri Martins; Rodrigues Conti, Paulo César

    2017-01-01

    To address the two following questions: (1) What kind of somatosensory abnormalities may be characterized in patients receiving dental implants (IMP), in ongoing inflammatory dental pulpitis (IP) patients, and in neuropathic pain (atypical odontalgia [AO]) patients? and (2) What sort of sensory and neural changes may result from dental implant placement surgery and pulpectomy? A total of 60 subjects were divided into three groups: the IMP (n = 20), IP (n = 20), and AO groups (n = 20). Quantitative sensory testing (QST) was performed preoperatively (baseline) for all three groups and postoperatively at 1 month and 3 months after dental implant placement or pulpectomy (in the IMP group and IP group, respectively). Statistical analyses were completed with one-way and two-way analysis of variance and z score transformations (α = 5%). The main findings of this study indicated that: (1) Elevations in mechanical detection threshold (MDT) and in current perception threshold (CPT) related to C-fiber activation, indicating a loss of function, were found at baseline in IP patients; (2) Somatosensory abnormalities such as allodynia, reduced MDT and mechanical pain threshold (MPT), and impaired pain modulation were found in AO patients; (3) No somatosensory alterations after implant placement were found in the IMP group; and (4) Somatosensory alterations in the form of reduction in the CPT related to C-fiber activation were reported 3 months after pulpectomy in the IP group. This study showed that somatosensory abnormalities were evident in AO and IP patients, and somatosensory alterations were seen in IP patients even 3 months after pulpectomy. However, no somatosensory alterations were seen after implant placement.

  4. Specific Language Impairment, Nonverbal IQ, Attention-Deficit/Hyperactivity Disorder, Autism Spectrum Disorder, Cochlear Implants, Bilingualism, and Dialectal Variants: Defining the Boundaries, Clarifying Clinical Conditions, and Sorting out Causes

    Science.gov (United States)

    Rice, Mabel L.

    2016-01-01

    Purpose: The purpose of this research forum article is to provide an overview of a collection of invited articles on the topic "specific language impairment (SLI) in children with concomitant health conditions or nonmainstream language backgrounds." Topics include SLI, attention-deficit/hyperactivity disorder, autism spectrum disorder,…

  5. Spirulina platensis Improves Mitochondrial Function Impaired by Elevated Oxidative Stress in Adipose-Derived Mesenchymal Stromal Cells (ASCs) and Intestinal Epithelial Cells (IECs), and Enhances Insulin Sensitivity in Equine Metabolic Syndrome (EMS) Horses.

    Science.gov (United States)

    Nawrocka, Daria; Kornicka, Katarzyna; Śmieszek, Agnieszka; Marycz, Krzysztof

    2017-08-03

    Equine Metabolic Syndrome (EMS) is a steadily growing life-threatening endocrine disorder linked to insulin resistance, oxidative stress, and systemic inflammation. Inflammatory microenvironment of adipose tissue constitutes the direct tissue milieu for various cell populations, including adipose-derived mesenchymal stromal cells (ASCs), widely considered as a potential therapeutic cell source in the course of the treatment of metabolic disorders. Moreover, elevated oxidative stress induces inflammation in intestinal epithelial cells (IECs)-the first-line cells exposed to dietary compounds. In the conducted research, we showed that in vitro application of Spirulina platensis contributes to the restoration of ASCs' and IECs' morphology and function through the reduction of cellular oxidative stress and inflammation. Enhanced viability, suppressed senescence, and improved proliferation of ASCs and IECs isolated from metabolic syndrome-affected individuals were evident following exposition to Spirulina. A protective effect of the investigated extract against mitochondrial dysfunction and degeneration was also observed. Moreover, our data demonstrate that Spirulina extract effectively suppressed LPS-induced inflammatory responses in macrophages. In vivo studies showed that horses fed with a diet based on Spirulina platensis supplementation lost weight and their insulin sensitivity improved. Thus, our results indicate the engagement of Spirulina platensis nourishing as an interesting alternative approach for supporting the conventional treatment of equine metabolic syndrome.

  6. Brainjacking: Implant Security Issues in Invasive Neuromodulation.

    Science.gov (United States)

    Pycroft, Laurie; Boccard, Sandra G; Owen, Sarah L F; Stein, John F; Fitzgerald, James J; Green, Alexander L; Aziz, Tipu Z

    2016-08-01

    The security of medical devices is critical to good patient care, especially when the devices are implanted. In light of recent developments in information security, there is reason to be concerned that medical implants are vulnerable to attack. The ability of attackers to exert malicious control over brain implants ("brainjacking") has unique challenges that we address in this review, with particular focus on deep brain stimulation implants. To illustrate the potential severity of this risk, we identify several mechanisms through which attackers could manipulate patients if unauthorized access to an implant can be achieved. These include blind attacks in which the attacker requires no patient-specific knowledge and targeted attacks that require patient-specific information. Blind attacks include cessation of stimulation, draining implant batteries, inducing tissue damage, and information theft. Targeted attacks include impairment of motor function, alteration of impulse control, modification of emotions or affect, induction of pain, and modulation of the reward system. We also discuss the limitations inherent in designing implants and the trade-offs that must be made to balance device security with battery life and practicality. We conclude that researchers, clinicians, manufacturers, and regulatory bodies should cooperate to minimize the risk posed by brainjacking. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Physical Impairment

    Science.gov (United States)

    Trewin, Shari

    Many health conditions can lead to physical impairments that impact computer and Web access. Musculoskeletal conditions such as arthritis and cumulative trauma disorders can make movement stiff and painful. Movement disorders such as tremor, Parkinsonism and dystonia affect the ability to control movement, or to prevent unwanted movements. Often, the same underlying health condition also has sensory or cognitive effects. People with dexterity impairments may use a standard keyboard and mouse, or any of a wide range of alternative input mechanisms. Examples are given of the diverse ways that specific dexterity impairments and input mechanisms affect the fundamental actions of Web browsing. As the Web becomes increasingly sophisticated, and physically demanding, new access features at the Web browser and page level will be necessary.

  8. Retrograde peri-implantitis

    Directory of Open Access Journals (Sweden)

    Mohamed Jumshad

    2010-01-01

    Full Text Available Retrograde peri-implantitis constitutes an important cause for implant failure. Retrograde peri-implantitis may sometimes prove difficult to identify and hence institution of early treatment may not be possible. This paper presents a report of four cases of (the implant placed developing to retrograde peri-implantitis. Three of these implants were successfully restored to their fully functional state while one was lost due to extensive damage. The paper highlights the importance of recognizing the etiopathogenic mechanisms, preoperative assessment, and a strong postoperative maintenance protocol to avoid retrograde peri-implant inflammation.

  9. Individual titanium zygomatic implant

    Science.gov (United States)

    Nekhoroshev, M. V.; Ryabov, K. N.; Avdeev, E. V.

    2018-03-01

    Custom individual implants for the reconstruction of craniofacial defects have gained importance due to better qualitative characteristics over their generic counterparts – plates, which should be bent according to patient needs. The Additive Manufacturing of individual implants allows reducing cost and improving quality of implants. In this paper, the authors describe design of zygomatic implant models based on computed tomography (CT) data. The fabrication of the implants will be carried out with 3D printing by selective laser melting machine SLM 280HL.

  10. Rutherford backscatter measurements on tellurium and cadmium implanted gallium arsenide

    International Nuclear Information System (INIS)

    Bell, E.C.

    1979-10-01

    The primary aim of the work described in this thesis was to examine implanted layers of the dopant impurities cadmium and tellurium in gallium arsenide and to experimentally assess their potential for producing electrically active layers. 1.5 MeV Rutherford backscattering measurements of lattice disorder and atom site location have been used to assess post implantation thermal annealing and elevated temperature implantations to site the dopant impurities on either gallium or arsenic lattice positions in an otherwise undisordered lattice. Pyrolitically deposited silicon dioxide was used as an encapsulant to prevent thermal dissociation of the gallium arsenide during annealing. It has been shown that high doses of cadmium and tellurium can be implanted without forming amorphous lattice disorder by heating the gallium arsenide during implantation to relatively low temperatures. Atom site location measurements have shown that a large fraction of a tellurium dose implanted at 180 0 C is located on or near lattice sites. Channeled backscatter measurements have shown that there is residual disorder or lattice strain in gallium arsenide implanted at elevated temperatures. The extent of this disorder has been shown to depend on the implanted dose and implantation temperature. The channeling effect has been used to measure annealing of the disorder. (author)

  11. He reemission implanted in metals

    International Nuclear Information System (INIS)

    Tanabe, T.

    2014-01-01

    Highlights: • Observation of He reemission of various metals under He + implantation at wide temperature range. • Materials examined are aluminum (Al), Nickel (Ni) and molybdenum (Mo). • He reemission is quite temperature dependent and different with materials. • Three metals show similar dependence on temperature normalized with respective melting point. • He reemission is successfully correlated with He behavior in metals. - Abstract: Helium (He) reemission of Al, Ni and Mo under energetic He implantation (10–30 keV) in wide temperature range is studied to understand behavior of implanted He in correlation with structure changes. The reemission behavior is categorized into 4 different temperature ranges with the normalized temperature (T m ) to the melting point of each metal. At elevated temperatures (well above ∼0.6 T m ), interstitial He atoms and/or He-vacancy (ies) clusters can migrate remaining no structure change and showing smooth reemission without any burst. Between ∼0.25 and 0.6 T m , He reemission always accompanies significant structure modification. For ∼04–0.6 T m , implanted He coalesce to make bubbles and the bubbles can move to the surface. Bubble migration accompanies materials flow to the surface resulting in fuzz surface or columnar structure, depending on implantation flux. Slower bubble motion at ∼0.25–0.4 prohibits the material migration. Instead the bubbles coalesce to grow large and multi-layered blistering appears as periodic reemission behavior. Below ∼0.25 T m , He migration is too slow for bubbles to grow large, but bubble density increases up to a certain fluence, where neighboring bubbles start to coalesce. Accordingly, He release is mostly caused by mechanical failure or blister rapture. With increasing fluence, all defects (bubbles and dislocation loops) tangle or inter connected with neighboring defects and accordingly He migration to the surface along the tangled or connected defects is enhanced

  12. Iowa Bedrock Surface Elevation

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — This Digital Elevation Model (DEM) of the bedrock surface elevation in Iowa was compiled using all available data, principally information from GEOSAM, supplemented...

  13. Auditory, Visual, and Auditory-Visual Speech Perception by Individuals with Cochlear Implants versus Individuals with Hearing Aids

    Science.gov (United States)

    Most, Tova; Rothem, Hilla; Luntz, Michal

    2009-01-01

    The researchers evaluated the contribution of cochlear implants (CIs) to speech perception by a sample of prelingually deaf individuals implanted after age 8 years. This group was compared with a group with profound hearing impairment (HA-P), and with a group with severe hearing impairment (HA-S), both of which used hearing aids. Words and…

  14. Comparative evaluation of peri-implant tissues in patients wearing mandibular overdenture with different implant platforms

    Directory of Open Access Journals (Sweden)

    Laércio Almeida de Melo

    2017-01-01

    Full Text Available Background: The poor hygiene of peri-implant tissues causes inflammation at tissue-implant interface, which may impair the rehabilitation success. The aim of this study was to evaluate the influence of external hexagon and Morse taper implants on peri-implant health in patients wearing mandibular overdentures for 1 year. Materials and Methods: A total of 46 implants were evaluated, 28 external hexagon and 18 Morse taper. Plaque index in the mini-abutment, bleeding index, peri-implant inflammation, keratinized mucosa zone, probing depth, and marginal mucosa level were evaluated after 3 months and 1 year of prostheses insertion. Results: Deeper probing was found in the external hexagon group compared with Morse taper (P = 0.024 after 1 year of rehabilitation. Although the Morse taper group exhibited worse scenario of peri-implant inflammation than the external hexagon group (P = 0.001, both groups showed reduced inflammation after 1 year. A larger keratinized mucosa zone was observed with external hexagon implants (P = 0.020. No significant difference was found between the groups for plaque index in the mini-abutment, bleeding index, and marginal mucosa level. Conclusion: In a follow-up period of 1 year, it was concluded that the external hexagon group had a larger probing depth than the Morse taper group. However, better periodontal conditions about inflammation and keratinized mucosa zone were found in external hexagon implants. It was found no influence of implant platform on plaque index in the mini-abutment, bleeding index, and marginal mucosa level.

  15. Radioactive implants for medical applications; Radioaktive Implantate fuer medizinische Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, M.

    2008-07-01

    dosimetry of 1-2 MeV electrons, the challenge arises from the short range (few millimeters only) in the tissue and the resulting steep dose decay. Therefore a Monte Carlo Simulation has been developed, based on the library GEANT4. In this dose planning system, apart form the possibility of schematic geometry, calculations based on patients computer tomography data have been made possible. For the validation of this simulation, a system for three-dimensional dosimetric measurements has been developed by means of a plastic scintillator in a water phantom. The simulations could be reproduced within a deviation of 10%. Furthermore, to establish a quality control for each implant produced, an electron counter system has been developed to measure activity. The calibration has been carried out by liquid scintillation counting. Additionally, Monte Carlo Simulations have been performed to allow for calibration of implant materials, which can hardly be diluted such as the used materials silicone or nickel titanium alloys. The measured changes of the material properties of silicone and the bioabsorbable polymer PLGA, which occur due to the production process, were reasonable, confirming the suitability as an implant material, in particular for the long-lasting fixation of the radionuclide. The implants have been tested in the context of two preclinical studies: (i) Otorhinolaryngology faces problems with congested paranasal sinuses, which entail infections. By the implantation of a radioactive silicone stent with an irradiation time of 7 days, it has been shown that an artificially created opening can be kept open on a long-term basis. (ii) In the field of ophthalmology the glaucoma is a wide-spread disease, which can cause blindness, resulting from an elevated intra-ocular pressure. However, it can be treated by a surgical intervention. For the first time, a bioabsorbable, radioactive implant has been used that is suitable to keep the artificially created drainage open, and hence, is

  16. Implantable Medical Devices

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Implantable Medical Devices Updated:Sep 16,2016 For Rhythm Control ... a Heart Attack Introduction Medications Surgical Procedures Implantable Medical Devices • Life After a Heart Attack • Heart Attack ...

  17. Intercavitary implants dosage calculation

    International Nuclear Information System (INIS)

    Rehder, B.P.

    The use of spacial geometry peculiar to each treatment for the attainment of intercavitary and intersticial implants dosage calculation is presented. The study is made in patients with intercavitary implants by applying a modified Manchester technique [pt

  18. Surface morphologies of He-implanted tungsten

    Energy Technology Data Exchange (ETDEWEB)

    Bannister, M.E., E-mail: bannisterme@ornl.gov [Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6371 (United States); Meyer, F.W.; Hijazi, H. [Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6371 (United States); Unocic, K.A.; Garrison, L.M.; Parish, C.M. [Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    2016-09-01

    Surface morphologies of tungsten surfaces, both polycrystalline and single-crystal [1 1 0], were investigated using SEM and FIB/SEM techniques after implantations at elevated surfaces temperatures (1200–1300 K) using well-characterized, mono-energetic He ion beams with a wide range of ion energies (218 eV–250 keV). Nanofuzz was observed on polycrystalline tungsten (PCW) following implantation of 100-keV He ions at a flux threshold of 0.9 × 10{sup 16} cm{sup −2} s{sup −1}, but not following 200-keV implantations with similar fluxes. No nanofuzz formation was observed on single-crystal [1 1 0] tungsten (SCW), despite fluxes exceeding those demonstrated previously to produce nanofuzz on polycrystalline tungsten. Pre-damaging the single-crystal tungsten with implanted C impurity interstitials did not significantly affect the surface morphologies resulting from the high-flux He ion implantations. The main factor leading to the different observed surface structures for the pristine and C-implanted single-crystal W samples appeared to be the peak He ion flux characterizing the different exposures. It was speculated that nanofuzz formation was not observed for any SCW target exposures because of increased incubation fluences required for such targets.

  19. Implantable electronic medical devices

    CERN Document Server

    Fitzpatrick, Dennis

    2014-01-01

    Implantable Electronic Medical Devices provides a thorough review of the application of implantable devices, illustrating the techniques currently being used together with overviews of the latest commercially available medical devices. This book provides an overview of the design of medical devices and is a reference on existing medical devices. The book groups devices with similar functionality into distinct chapters, looking at the latest design ideas and techniques in each area, including retinal implants, glucose biosensors, cochlear implants, pacemakers, electrical stimulation t

  20. Firm Elevation of Reconstructed Auricle Using Polydactyly Digit in Microtia.

    Science.gov (United States)

    Jang, Suk Yoon; Kim, Woo Seob; Kim, Han Koo; Bae, Tae Hui

    2018-03-01

    Total ear reconstruction for microtia is usually accomplished in 2 stages which is known as Nagata technique. After framework fabrication and implantation, the elevation procedure is required as a second step surgery. The authors are introducing a novel material for augmenting projection of rib cartilage framework in microtia treatment.

  1. Prosthetic Rehabilitation of a Patient with Mandibular Resection Prosthesis Using Mini Dental Implants (MDIs) – Case Report

    OpenAIRE

    Vojvodić, Denis; Čelebić, Asja; Mehulić, Ketij; Žabarović, Domagoj

    2012-01-01

    Physical disfigurement and functional impairments associated with facial trauma are a challenge to a prosthodontist, because even novel sophisticated surgical reconstructive techniques fail to provide adequate support for dental resection prosthesis. Therefore, different endosseous implants are often used as prosthesis-supporting elements. Manufacturers of dental implants have recently presented mini dental implants (MDIs) with diameter of only 1.8–2.4 mm. These implants allow very suitable p...

  2. De stille elever

    DEFF Research Database (Denmark)

    Winther-Lindqvist, Ditte Alexandra

    2012-01-01

    Det er blevet en afgørende samværskompetence i uddannelsessystemet at stå aktivt frem og deltage verbalt i skoleklassens liv både fagligt og socialt. Men ikke alle elever deltager lige villigt verbalt i plenum. Artiklen handler om de stille elever og konsekvenserne af stillehed i skolen. Det...... foreslås at skolesystemet sanktionerer ældre elever hårdere for stillehed end yngre elever og det forklares med at skolelivet også er en kultivering henimod elevhed som social identitet og denne er der forventning om at eleverne mestrer i udskolingen....

  3. Piezoelectric surgery in implant dentistry: clinical applications

    Directory of Open Access Journals (Sweden)

    Lydia Masako Ferreira

    2009-01-01

    Full Text Available Pizosurgery has therapeutic characteristics in osteotomies, such as extremely precise, selective and millimetric cuts and a clear operating field. Piezoelectricity uses ultrasonic frequencies, which cause the points specially designed for osteotomy to vibrate. The points of the instrument oscillate, allowing effective osteotomy with minimal or no injury to the adjacent soft tissues, membranes and nerve tissues. This article presents the various applications of piezoelectricity in oral implant surgery such as: removal of autogenous bone; bone window during elevation of the sinus membrane and removal of fractured implants. The cavitational effect caused by the vibration of the point and the spray of physiological solution, provided a field free of bleeding and easy to visualize. The study showed that the piezoelectric surgery is a new surgical procedurethat presents advantages for bone cutting in many situations in implant dentistry, with great advantages in comparison with conventional instrumentation. Operating time is longer when compared with that of conventional cutters.

  4. Trends in cochlear implants.

    Science.gov (United States)

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.

  5. Benefits and Risks of Cochlear Implants

    Science.gov (United States)

    ... and Medical Procedures Implants and Prosthetics Cochlear Implants Benefits and Risks of Cochlear Implants Share Tweet Linkedin ... the Use of Cochlear Implants What are the Benefits of Cochlear Implants? For people with implants: Hearing ...

  6. [Perioperative nursing of internal sinus floor elevation surgery with piezosurgery].

    Science.gov (United States)

    He, Jing; Lei, Yiling; Wang, Liqiong

    2013-12-01

    This study aims to summarize the nursing experience in the internal sinus floor elevation surgery with piezosurgery. The medical records of 48 patients who underwent sinus floor elevation surgery with piezosurgery in the Department of Implantation, West China Hospital of Stomatology, Sichuan University, were reviewed. The preoperative, intraoperative, and postoperative nursing methods were summarized. All 48 patients underwent smooth surgeries and did not encounter complications. Careful preoperative preparation, careful and meticulous intraoperative nursing cooperation, and provision of sufficient health education after surgery to the patients are the key factors that ensure the success of internal sinus floor elevation surgery with piezosurgery.

  7. Undervisning af tosprogede elever

    DEFF Research Database (Denmark)

    Horst, Christian

    2003-01-01

    Artiklen fremdrager hovedresultaterne fra Virginia P. Collier's og Wayne P. Thomas's længdeundersøgelser af tosprogede elever i USA, som formentlig er de mest omfattende undersøgelser af undervisningen af tosprogede elever overhovedet. Resultaterne diskuteres i relation til udviklingen af en...

  8. Effects of elevated CO

    NARCIS (Netherlands)

    Xue, Sha; Yang, Xiaomei; Liu, Guobin; Gai, Lingtong; Zhang, Changsheng; Ritsema, Coen J.; Geissen, Violette

    2017-01-01

    Elevated CO2 and drought are key consequences of climate change and affect soil processes and plant growth. This study investigated the effects of elevated CO2 and drought on the microbial biomass and enzymatic activities in the rhizospheres of Bothriochloa ischaemum and

  9. Benefits of simultaneous bilateral cochlear implantation on verbal reasoning skills in prelingually deaf children

    NARCIS (Netherlands)

    Jacobs, Evi; Langereis, Margreet C.; Frijns, Johan H. M.; Free, Rolien H.; Goedegebure, Andre; Smits, Cas; Stokroos, Robert J.; Ariens-Meijer, Saskia A. M.; Mylanus, Emmanuel A. M.; Vermeulen, Anneke M.

    2016-01-01

    Background: Impaired auditory speech perception abilities in deaf children with hearing aids compromised their verbal intelligence enormously. The availability of unilateral cochlear implantation (Cl) auditory speech perception and spoken vocabulary enabled them to reach near ageappropriate levels.

  10. Benefits of simultaneous bilateral cochlear implantation on verbal reasoning skills in prelingually deaf children

    NARCIS (Netherlands)

    Jacobs, E.; Langereis, M.C.; Frijns, J.H.; Free, R.H.; Goedegebure, A.; Smits, C.; Stokroos, R.J.; Ariens-Meijer, S.A.; Mylanus, E.A.M.; Vermeulen, A.M.J.

    2016-01-01

    BACKGROUND: Impaired auditory speech perception abilities in deaf children with hearing aids compromised their verbal intelligence enormously. The availability of unilateral cochlear implantation (CI) auditory speech perception and spoken vocabulary enabled them to reach near ageappropriate levels.

  11. Chronically implanted pressure sensors: challenges and state of the field.

    Science.gov (United States)

    Yu, Lawrence; Kim, Brian J; Meng, Ellis

    2014-10-31

    Several conditions and diseases are linked to the elevation or depression of internal pressures from a healthy, normal range, motivating the need for chronic implantable pressure sensors. A simple implantable pressure transduction system consists of a pressure-sensing element with a method to transmit the data to an external unit. The biological environment presents a host of engineering issues that must be considered for long term monitoring. Therefore, the design of such systems must carefully consider interactions between the implanted system and the body, including biocompatibility, surgical placement, and patient comfort. Here we review research developments on implantable sensors for chronic pressure monitoring within the body, focusing on general design requirements for implantable pressure sensors as well as specifications for different medical applications. We also discuss recent efforts to address biocompatibility, efficient telemetry, and drift management, and explore emerging trends.

  12. Annealing of Al implanted 4H silicon carbide

    International Nuclear Information System (INIS)

    Hallen, A; Suchodolskis, A; Oesterman, J; Abtin, L; Linnarsson, M

    2006-01-01

    Al ions were implanted with multiple energies up to 250 keV at elevated temperatures in n-type 4H SiC epitaxial layers to reach a surface concentration of 1x10 20 cm -3 . These samples were then annealed at temperatures between 1500 and 1950 deg. C. A similar 4H SiC epitaxial sample was implanted by MeV Al ions to lower doses and annealed only at 200 and 400 deg. C. After annealing, cross-sections of the samples were characterized by scanning spreading resistance microscopy (SSRM). The results show that the resistivity of high-dose Al implanted samples has not reached a saturated value, even after annealing at the highest temperature. For the MeV Al implanted sample, the activation of Al has not yet started, but a substantial annealing of the implantation induced damage can be seen from the SSRM depth profiles

  13. Elevator and hydraulics; Elevator to yuatsu

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, I. [Hitachi, Ltd., Tokyo (Japan)

    1994-07-15

    A hydraulic type elevator is installed in relatively lower buildings as compared with a rope type elevator, but the ratio in the number of installation of the former elevator is increasing. This paper explains from its construction and features to especially various control systems for the riding comfort and safety. A direct push-up system with hydraulic jacks arranged beneath a car, and an indirect push-up system that has hydraulic jacks arranged on flank of a car and transmits the movement of a plunger via a rope are available. The latter system eliminates the need of large holes to embed hydraulic jacks. While the speed is controlled by controlling flow rates of high-pressure oil, the speed, position, acceleration and even time differential calculus of the acceleration must be controlled severely. The system uses two-step control for the through-speed and the landing speed. Different systems that have been realized may include compensation for temperatures in flow rate control valves, load pressures, and oil viscosity, from learning control to fuzzy control for psychological effects, or control of inverters in motors. 13 refs., 12 figs., 1 tab.

  14. Implant therapy in the esthetic zone: smile line assessment.

    Science.gov (United States)

    Kourkouta, Stella

    2011-04-01

    Assessment of the smile or lip line is imperative when implant therapy is carried out in the esthetic zone. The smile is generally defined as high, average, or low. Females are reported to have higher lip lines than males, which means that they are at greater risk when placing and restoring implants in the esthetic zone. Maximum upper lip elevation, usually observed during a strained posed smile, should be assessed. This paper discusses some clinical observations and concepts in relation to smile line assessment for implant therapy in the esthetic zone. (Int J Periodontics Restorative Dent 2011;31:195-201.).

  15. Subgingival Microbiome Colonization and Cytokine Production during Early Dental Implant Healing.

    Science.gov (United States)

    Payne, Jeffrey B; Johnson, Paul G; Kok, Car Reen; Gomes-Neto, João C; Ramer-Tait, Amanda E; Schmid, Marian J; Hutkins, Robert W

    2017-01-01

    Little is known about longitudinal development of the peri-implant subgingival microbiome and cytokine production as a new sulcus forms after dental implant placement. Therefore, the purpose of this observational study was to evaluate simultaneous longitudinal changes in the oral microbiome and cytokine production in the developing peri-implant sulcus compared to control natural teeth. Four and 12 weeks after implant placement and abutment connection, a dental implant and a natural tooth were sampled in 25 patients for subgingival plaque and gingival crevicular fluid (GCF [around teeth] and peri-implant crevicular fluid [PICF] around implants). DNA from plaque samples was extracted and sequenced using Illumina-based 16S rRNA sequencing. GCF and PICF samples were analyzed using a customized Milliplex human cytokine and chemokine magnetic bead panel. Beta diversity analysis revealed that natural teeth and implants had similar subgingival microbiomes, while teeth had greater alpha diversity than implants. At the genus level, however, few differences were noted between teeth and dental implants over 12 weeks. Specifically, Actinomyces and Selenomonas were significantly elevated around teeth versus dental implants at both 4 weeks and 12 weeks, while Corynebacterium and Campylobacter were significantly elevated only at 4 weeks around teeth. The only difference between PICF and GCF biomarkers was significantly elevated granulocyte-macrophage colony-stimulating factor levels around teeth versus dental implants at the 4-week visit. The subgingival microbiome and cytokine production were similar between teeth and implants during early healing, suggesting that these profiles are driven by the patient following dental implant placement and are not determined by anatomical niche. IMPORTANCE Dental implants are a common treatment option offered to patients for tooth replacement. However, little is known regarding initial colonization of the subgingival microbiome and

  16. Influences of serum from ozone-exposed pregnant rats in an in vitro model of implantation

    Science.gov (United States)

    In our previous studies, ozone (O3) exposure during implantation [gestational day (GD) 5 and 6)] in rats resulted in intrauterine growth restriction (IUGR), suggesting impairment of implantation with exposure. The aim of this study was to (1) determine if serum collected from pre...

  17. Elevators or stairs?

    Science.gov (United States)

    Shah, Sachin; O’Byrne, Michael; Wilson, Merne; Wilson, Thomas

    2011-01-01

    Background: Staff in hospitals frequently travel between floors and choose between taking the stairs or elevator. We compared the time savings with these two options. Methods: Four people aged 26–67 years completed 14 trips ranging from one to six floors, both ascending and descending. We compared the amount of time per floor travelled by stairs and by two banks of elevators. Participants reported their fatigue levels using a modified Borg scale. We performed two-way analysis of variance to compare the log-transformed data, with participant and time of day as independent variables. Results: The mean time taken to travel between each floor was 13.1 (standard deviation [SD] 1.7) seconds by stairs and 37.5 (SD 19.0) and 35.6 (SD 23.1) seconds by the two elevators (F = 8.61, p elevator equaled about 15 minutes a day. Self-reported fatigue was less than 13 (out of 20) on the Borg scale for all participants, and they all stated that they were able to continue their duties without resting. The extra time associated with elevator use was because of waiting for its arrival. There was a difference in the amount of time taken to travel by elevator depending on the time of day and day of the week. Interpretation: Taking the stairs rather than the elevator saved about 15 minutes each workday. This 3% savings per workday could translate into improved productivity as well as increased fitness. PMID:22159365

  18. Optical effects of ion implantation

    International Nuclear Information System (INIS)

    Townsend, P.D.

    1987-01-01

    The review concerns the effects of ion implantation that specifically relate to the optical properties of insulators. Topics which are reviewed include: ion implantation, ion range and damage distributions, colour centre production by ion implantation, high dose ion implantation, and applications for integrated optics. Numerous examples are presented of both diagnostic and industrial examples of ion implantation effects in insulators. (U.K.)

  19. Ion implantation in semiconductors

    International Nuclear Information System (INIS)

    Gusev, V.; Gusevova, M.

    1980-01-01

    The historical development is described of the method of ion implantation, the physical research of the method, its technological solution and practical uses. The method is universally applicable, allows the implantation of arbitrary atoms to an arbitrary material, ensures high purity of the doping element. It is linked with sample processing at low temperatures. In implantation it is possible to independently change the dose and energy of the ions thereby affecting the spatial distribution of the ions. (M.S.)

  20. Ion implantation in semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Gusev, V; Gusevova, M

    1980-06-01

    The historical development of the method of ion implantation, the physical research of the method, its technological solution and practical uses is described. The method is universally applicable, allows the implantation of arbitrary atoms to an arbitrary material and ensures high purity of the doping element. It is linked with sample processing at low temperatures. In implantation it is possible to independently change the dose and energy of the ions thereby affecting the spatial distribution of the ions.

  1. Trends in Cochlear Implants

    OpenAIRE

    Zeng, Fan-Gang

    2004-01-01

    More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic as...

  2. Ion implantation technology

    CERN Document Server

    Downey, DF; Jones, KS; Ryding, G

    1993-01-01

    Ion implantation technology has made a major contribution to the dramatic advances in integrated circuit technology since the early 1970's. The ever-present need for accurate models in ion implanted species will become absolutely vital in the future due to shrinking feature sizes. Successful wide application of ion implantation, as well as exploitation of newly identified opportunities, will require the development of comprehensive implant models. The 141 papers (including 24 invited papers) in this volume address the most recent developments in this field. New structures and possible approach

  3. High energy ion implantation

    International Nuclear Information System (INIS)

    Ziegler, J.F.

    1985-01-01

    High energy ion implantation offers the oppertunity for unique structures in semiconductor processing. The unusual physical properties of such implantations are discussed as well as the special problems in masking and damage annealing. A review is made of proposed circuit structures which involve deep implantation. Examples are: deep buried bipolar collectors fabricated without epitaxy, barrier layers to reduce FET memory sensitivity to soft-fails, CMOS isolation well structures, MeV implantation for customization and correction of completed circuits, and graded reach-throughs to deep active device components. (orig.)

  4. [Silastic implant and synovitis].

    Science.gov (United States)

    Sennwald, G

    1989-07-22

    The silastic implant based on siloxane polymere induces granulomatous synovitis in certain predisposed individuals, a reaction which may continue even after removal of the implant. This is also true of a prosthesis of the trapezium in two of our patients, though to a lesser degree. This is probably the reason why the problem has not yet been widely recognized. The hypothesis is put forward that an enzymatic predisposition may allow chemical degradation of the fragmented silastic implant into a toxic component responsible for the pathologic condition. The slow progression of the lesions is a challenge for the future and puts in question the further use of silastic implants.

  5. Cochlear implant magnet retrofit.

    Science.gov (United States)

    Cohen, N L; Breda, S D; Hoffman, R A

    1988-06-01

    An implantable magnet is now available for patients who have received the standard Nucleus 22-channel cochlear implant and who are not able to wear the headband satisfactorily. This magnet is attached in piggy-back fashion to the previously implanted receiver/stimulator by means of a brief operation under local anesthesia. Two patients have received this magnet retrofit, and are now wearing the headset with greater comfort and satisfaction. It is felt that the availability of this magnet will increase patient compliance in regard to hours of implant usage.

  6. [Cochlear implant in children: rational, indications and cost/efficacy].

    Science.gov (United States)

    Martini, A; Bovo, R; Trevisi, P; Forli, F; Berrettini, S

    2013-06-01

    A cochlear implant (CI) is a partially implanted electronic device that can help to provide a sense of sound and support speech to severely to profoundly hearing impaired patients. It is constituted by an external portion, that usually sits behind the ear and an internal portion surgically placed under the skin. The external components include a microphone connected to a speech processor that selects and arranges sounds pucked up by the microphone. This is connected to a transmitter coil, worn on the side of the head, which transmits data to an internal receiver coil placed under the skin. The received data are delivered to an array of electrodes that are surgically implanted within the cochlea. The primary neural targets of the electrodes are the spiral ganglion cells which innervate fibers of the auditory nerve. When the electrodes are activated by the signal, they send a current along the auditory nerve and auditory pathways to the auditory cortex. Children and adults who are profoundly or severely hearing impaired can be fitted with cochlear implants. According to the Food and Drug Administration, approximately 188,000 people worldwide have received implants. In Italy it is extimated that there are about 6-7000 implanted patients, with an average of 700 CI surgeries per year. Cochlear implantation, followed by intensive postimplantation speech therapy, can help young children to acquire speech, language, and social skills. Early implantation provides exposure to sounds that can be helpful during the critical period when children learn speech and language skills. In 2000, the Food and Drug Administration lowered the age of eligibility to 12 months for one type of CI. With regard to the results after cochlear implantation in relation to early implantation, better linguistic results are reported in children implanted before 12 months of life, even if no sufficient data exist regarding the relation between this advantage and the duration of implant use and how long

  7. Elevated temperature fracture mechanics

    International Nuclear Information System (INIS)

    Tomkins, B.

    1979-01-01

    The application of fracture mechanics concepts to cracks at elevated temperatures is examined. Particular consideration is given to the characterisation of crack tip stress-strain fields and parameters controlling crack extension under static and cyclic loads. (author)

  8. Cardiovascular disease risk factors and cognitive impairment.

    Science.gov (United States)

    Nash, David T; Fillit, Howard

    2006-04-15

    The role of cardiovascular disease risk factors in the occurrence and progression of cognitive impairment has been the subject of a significant number of publications but has not achieved widespread recognition among many physicians and educated laymen. It is apparent that the active treatment of certain of these cardiovascular disease risk factors is accompanied by a reduced risk for cognitive impairment. Patients with hypertension who are treated experience fewer cardiovascular disease events as well as less cognitive impairment than similar untreated patients. Patients who exercise may present with less cognitive impairment, and obesity may increase the risk for cognitive impairment. Lipid abnormalities and genetic markers are associated with an increased risk for cardiovascular disease and cognitive impairment. Autopsy studies have demonstrated a correlation between elevated levels of cholesterol and amyloid deposition in the brain. Research has demonstrated a relation between atherosclerotic obstruction lesions in the circle of Willis and dementia. Diabetes mellitus is associated with an increased risk for cardiovascular disease and cognitive impairment. A number of nonpharmacologic factors have a role in reducing the risk for cognitive impairment. Antioxidants, fatty acids, and micronutrients may have a role, and diets rich in fruits and vegetables and other dietary approaches may improve the outlook for patients considered at risk for cognitive impairment.

  9. Indsatser for tosprogede elever

    DEFF Research Database (Denmark)

    Andersen, Dines; Jakobsen, Vibeke; Jensen, Vibeke Myrup

    Fagligt set klarer tosprogede elever sig dårligere i skolen og det videre uddannelsessystem end ’danske’ elever. Kommuner og folkeskoler har derfor sat en række tiltag i værk, som sigter mod at forbedre de tosprogede elevers skole- og uddannelsessituation. Rapporten kortlægger og analyserer...... af klasseundervisningen. Analysen viser, at de elever, der bliver taget ud af klassen for at få ekstra undervisning i dansk som andetsprog, klarer sig dårligere end elever, der modtager ekstraundervisningen i klassen eller uden for skoletid. Undersøgelsen er baseret på spørgeskemaundersøgelser blandt...... kommunale forvaltningschefer, skoleledere, lærere og forældre til børn i 2. klasse samt lærere til og elever i 9. klasse, SFI’s forløbsundersøgelse af årgang 1995 og registerdata. Undersøgelsen er via Ministeriet for Børn og Undervisning betalt med midler fra satspuljeaftalen 2009 om integration....

  10. Cerebral Pulsatility Index Is Elevated in Patients with Elevated Right Atrial Pressure.

    Science.gov (United States)

    Lahiri, Shouri; Schlick, Konrad H; Padrick, Matthew M; Rinsky, Brenda; Gonzalez, Nestor; Jones, Heather; Mayer, Stephan A; Lyden, Patrick D

    2018-01-01

    Extracerebral venous congestion can precipitate intracranial hypertension due to obstruction of cerebral blood outflow. Conditions that increase right atrial pressure, such as hypervolemia, are thought to increase resistance to jugular venous outflow and contribute to cerebro-venous congestion. Cerebral pulsatility index (CPI) is considered a surrogate marker of distal cerebrovascular resistance and is elevated with intracranial hypertension. Thus, we sought to test the hypothesis that elevated right atrial pressure is associated with increased CPI compared to normal right atrial pressure. We retrospectively reviewed 61 consecutive patients with subarachnoid hemorrhage. We calculated CPI from transcranial Doppler studies and correlated these with echocardiographic measures of right atrial pressure. CPIs were compared from patients with elevated and normal right atrial pressure. There was a significant difference between CPI obtained from all patients with elevated right atrial pressure compared to those with normal right atrial pressure (P right and left hemispheric CPI from patients with both elevated and normal right atrial pressure. Patients with elevated right atrial pressure had significantly higher CPI compared to patients with normal right atrial pressure. These findings suggest that cerebro-venous congestion due to impaired jugular venous outflow may increase distal cerebrovascular resistance as measured by CPI. Since elevated CPI is associated with poor outcome in numerous neurological conditions, future studies are needed to elucidate the significance of these results in other populations. Copyright © 2017 by the American Society of Neuroimaging.

  11. Evaluation of Functionalized Porous Titanium Implants for Enhancing Angiogenesis in Vitro

    Directory of Open Access Journals (Sweden)

    Laura Roland

    2016-04-01

    Full Text Available Implant constructs supporting angiogenesis are favorable for treating critically-sized bone defects, as ingrowth of capillaries towards the center of large defects is often insufficient. Consequently, the insufficient nutritional supply of these regions leads to impaired bone healing. Implants with specially designed angiogenic supporting geometry and functionalized with proangiogenic cytokines can enhance angiogenesis. In this study, Vascular Endothelial Growth Factor (VEGF and High Mobility Group Box 1 (HMGB1 were used for incorporation into poly-ε-caprolactone (PCL-coated porous titanium implants. Bioactivity of released factors and influence on angiogenesis of functionalized implants were evaluated using a migration assay and angiogenesis assays. Both implants released angiogenic factors, inducing migration of endothelial cells. Also, VEGF-functionalized PCL-coated titanium implants enhanced angiogenesis in vitro. Both factors were rapidly released in high doses from the implant coating during the first 72 h.

  12. Plasma immersion ion implantation: duplex layers from a single process

    International Nuclear Information System (INIS)

    Hutchings, R.; Collins, G.A.; Tendys, J.

    1992-01-01

    Plasma immersion ion implantation (PI 3 ) is an alternative non-line-of-sight technique for implanting ions directly from a plasma which surrounds the component to be treated. In contrast to plasma source ion implantation, the PI 3 system uses an inductively coupled r.f. plasma. It is shown that nitrogen can be retained during implantation at elevated temperatures, even for unalloyed steels. This allows controlled diffusion of nitrogen to greater depths, thereby improving the load bearing capacity of the implanted layer. Components can be heated directly, using the energy deposited by the incident ions during the pulsed implantation. The necessary temperature control can be accomplished simply by regulating the frequency and length of the high voltage pulses applied to the component. Chemical depth profiles and microstructural data obtained from H13 tool steel are used to show that PI 3 can, in a single process, effectively produce a duplex subsurface structure. This structure consists of an outer non-equilibrium layer typical of nitrogen implantation (containing in excess of 20 at.% nitrogen) backed by a substantial diffusion zone of much lower nitrogen content. The relationship between implantation temperature and the resultant subsurface microstructure is explored. (orig.)

  13. Implantation damage in heavy gas implanted 4H-SiC

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, C. [Institut Pprime, CNRS, Université de Poitiers, ENSMA, UPR 3346, Département Physique et Mécanique des Matériaux, Bd Marie et Pierre Curie, BP 30179, 86962 Futuroscope Chasseneuil Cedex (France); Nicolaï, J., E-mail: julien.nicolai@univ-poitiers.fr [Institut Pprime, CNRS, Université de Poitiers, ENSMA, UPR 3346, Département Physique et Mécanique des Matériaux, Bd Marie et Pierre Curie, BP 30179, 86962 Futuroscope Chasseneuil Cedex (France); Declémy, A. [Institut Pprime, CNRS, Université de Poitiers, ENSMA, UPR 3346, Département Physique et Mécanique des Matériaux, Bd Marie et Pierre Curie, BP 30179, 86962 Futuroscope Chasseneuil Cedex (France); Gilabert, E. [Centre d’Etude Nucléaire de Bordeaux-Gradignan, 33175 Gradignan Cedex (France); Beaufort, M.-F.; Barbot, J.-F. [Institut Pprime, CNRS, Université de Poitiers, ENSMA, UPR 3346, Département Physique et Mécanique des Matériaux, Bd Marie et Pierre Curie, BP 30179, 86962 Futuroscope Chasseneuil Cedex (France)

    2016-05-01

    Single crystals of SiC were implanted with heavy inert gases (Xe, Ar) at elevated temperatures (300–800 °C) and for a large range of fluence (1 × 10{sup 12}–1 × 10{sup 15} ions cm{sup −2}). Thermodesorption measurements suggest that gas is trapped by implantation-induced vacancy-type defects impeding any gas diffusion. The damage accumulation versus dose was studied through the tensile elastic strain determined by using X-ray diffraction. Results show that at low dose the strain is predictable via a thermally activated direct impact model. The low thermal activation energy at saturation suggests a dynamic recovery process dominated by the migration of interstitial-type defects as its relaxation during post thermal annealing. As compared with light-gas implantation the heavy-gas to defect ratio is low enhancing the formation of strongly perturbed zones rather than the formation of bubble precursors.

  14. Percutaneous and skeletal biocarbon implants

    Science.gov (United States)

    Mooney, V.

    1977-01-01

    Review of carbon implants developed by NASA discussed four different types of implants and subsequent improvements. Improvements could be of specific interest to rehabilitation centers and similar organizations.

  15. Degradable Implantate: Entwicklungsbeispiele

    Science.gov (United States)

    Ruffieux, Kurt; Wintermantel, Erich

    Resorbierbare Implantate werden seit mehreren Jahrzehnten in der Implantologie eingesetzt. Bekannt wurden diese Biomaterialien mit dem Aufkommen von sich selbst auflösenden Nahtfäden auf der Basis von synthetisch hergestellten Polylactiden und Polyglycoliden in den 70er Jahren. In einem nächsten Schritt wurden Implantate wie Platten und Schrauben zur Gewebefixation aus den gleichen Biomaterialien hergestellt.

  16. Risks of Breast Implants

    Science.gov (United States)

    ... have a risk of developing a type of cancer called breast implant-associated anaplastic large cell lymphoma (BIA-ALCL) in the breast tissue surrounding the implant. BIA-ALCL is not breast cancer. Women diagnosed with BIA-ALCL may need to ...

  17. Ion implantation of metals

    International Nuclear Information System (INIS)

    Dearnaley, G.

    1976-01-01

    In this part of the paper descriptions are given of the effects of ion implantation on (a) friction and wear in metals; and (b) corrosion of metals. In the study of corrosion, ion implantation can be used either to introduce a constituent that is known to convey corrosion resistance, or more generally to examine the parameters which control corrosion. (U.K.)

  18. Ion implantation into diamond

    International Nuclear Information System (INIS)

    Sato, Susumu

    1994-01-01

    The graphitization and the change to amorphous state of diamond surface layer by ion implantation and its characteristics are reported. In the diamond surface, into which more than 10 16 ions/cm 2 was implanted, the diamond crystals are broken, and the structure changes to other carbon structure such as amorphous state or graphite. Accompanying this change of structure, the electric conductivity of the implanted layer shows two discontinuous values due to high resistance and low resistance. This control of structure can be done by the temperature of the base during the ion implantation into diamond. Also it is referred to that by the base temperature during implantation, the mutual change of the structure between amorphous state and graphite can be controlled. The change of the electric resistance and the optical characteristics by the ion implantation into diamond surface, the structural analysis by Raman spectroscopy, and the control of the structure of the implanted layer by the base temperature during implantation are reported. (K.I.)

  19. Bone compaction enhances implant fixation in a canine gap model

    DEFF Research Database (Denmark)

    Kold, Søren; Rahbek, Ole; Toft, Marianne

    2005-01-01

    A new bone preparation technique, compaction, has increased fixation of implants inserted with exact-fit or press-fit to bone. Furthermore, a demonstrated spring-back effect of compacted bone might be of potential value in reducing the initial gaps that often exist between clinical inserted...... implants and bone. However, it is unknown whether the compression and breakage of trabeculae during the compaction procedure results in impaired gap-healing of compacted bone. Therefore, we compared compaction with conventional drilling in a canine gap model. Grit-blasted titanium implants (diameter 6 mm...... that the beneficial effect of reduced gap size, as compacted bone springs back, is not eliminated by an impaired gap-healing of compacted bone....

  20. Number of implants for mandibular implant overdentures: a systematic review

    Science.gov (United States)

    Lee, Jeong-Yol; Kim, Ha-Young; Bryant, S. Ross

    2012-01-01

    PURPOSE The aim of this systematic review is to address treatment outcomes of Mandibular implant overdentures relative to implant survival rate, maintenance and complications, and patient satisfaction. MATERIALS AND METHODS A systematic literature search was conducted by a PubMed search strategy and hand-searching of relevant journals from included studies. Randomized Clinical Trials (RCT) and comparative clinical trial studies on mandibular implant overdentures until August, 2010 were selected. Eleven studies from 1098 studies were finally selected and data were analyzed relative to number of implants. RESULTS Six studies presented the data of the implant survival rate which ranged from 95% to 100% for 2 and 4 implant group and from 81.8% to 96.1% for 1 and 2 implant group. One study, which statistically compared implant survival rate showed no significant differences relative to the number of implants. The most common type of prosthetic maintenance and complications were replacement or reattaching of loose clips for 2 and 4 implant group, and denture repair due to the fracture around an implant for 1 and 2 implant groups. Most studies showed no significant differences in the rate of prosthetic maintenance and complication, and patient satisfaction regardless the number of implants. CONCLUSION The implant survival rate of mandibular overdentures is high regardless of the number of implants. Denture maintenance is likely not inflenced substantially by the number of implants and patient satisfaction is typically high again regardless os the number of implants. PMID:23236572

  1. Ion implantation into iron

    International Nuclear Information System (INIS)

    Iwaki, Masaya

    1978-01-01

    The distribution of implanted ions in iron, the friction characteristics and the corrosion of iron were studied. The distribution of Ni or Cr ions implanted into mild steel was measured. The accelerated voltage was 150 keV, and the beam current density was about 2 microampere/cm 2 . The measurement was made with an ion microanalyzer. The measured distribution was compared with that of LSS theory. Deep invasion of Ni was seen in the measured distribution. The distribution of Cr ions was different from the distribution calculated by the LSS theory. The relative friction coefficient of mild steel varied according to the dose of implanted Cu or N ions, and to the accelerating voltage. Formation of compound metals on the surfaces of metals by ion-implantation was investigated for the purpose to prevent the corrosion of metals. The resistance of mild steel in which Ni ions were implanted was larger than that of mild steel without any treatment. (Kato, T.)

  2. Influence of Palatal Coverage and Implant Distribution on Implant Strain in Maxillary Implant Overdentures.

    Science.gov (United States)

    Takahashi, Toshihito; Gonda, Tomoya; Mizuno, Yoko; Fujinami, Yozo; Maeda, Yoshinobu

    2016-01-01

    Maxillary implant overdentures are often used in clinical practice. However, there is no agreement or established guidelines regarding prosthetic design or optimal implant placement configuration. The purpose of this study was to examine the influence of palatal coverage and implant number and distribution in relation to impact strain under maxillary implant overdentures. A maxillary edentulous model with implants and experimental overdentures with and without palatal coverage was fabricated. Four strain gauges were attached to each implant, and they were positioned in the anterior, premolar, and molar areas. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the implant strains were compared using one-way analysis of variance (P = .05). The palatolabial strain was much higher on anterior implants than on other implants in both denture types. Although there was no significant difference between the strain under dentures with and without palatal coverage, palateless dentures tended to result in higher implant strain than dentures with palatal coverage. Dentures supported by only two implants registered higher strain than those supported by four or six implants. Implants under palateless dentures registered higher strain than those under dentures with palatal coverage. Anterior implants exhibited higher palatolabial strain than other implants regardless of palatal coverage and implant configuration; it is therefore recommended that maxillary implant overdentures should be supported by six implants with support extending to the distal end of the arch.

  3. Metallic implants and exposure to radiofrequency radiation

    International Nuclear Information System (INIS)

    Joyner, K.H.; Fleming, A.H.F.; MacFarlane, I.P.; Hocking, B.

    1988-01-01

    There is increasing use of radiofrequency radiation (RFR) in industry for communications, welding, security, radio, medicine, navigation etc. It has been recognised for some years that RFR may interact with cardiac pacemakers and steps have been taken to prevent this interference. It is less well recognised that other metallic implants may also act as antennas in an RFR field and possibly cause adverse health effects by heating local tissues. There are a large and increasing number of implants having metal components which may be found in RFR workers. These implants include artificial joints, rods and plates used in orthopaedics, rings in heart valves, wires in sutures, bionic ears, subcutaneous infusion systems and (external) transdermal drug delivery patches 1 . The physician concerned with job placement of such persons requires information on the likelihood of an implant interacting with RFR so as to impair health. The following outlines the approach developed in Telecom Australia, beginning with the general principles and then presenting a specific example discussion of a specific example

  4. Cochlear Implantation in Siblings With Refsum's Disease.

    Science.gov (United States)

    Stähr, Kerstin; Kuechler, Alma; Gencik, Martin; Arnolds, Judith; Dendy, Meaghan; Lang, Stephan; Arweiler-Harbeck, Diana

    2017-08-01

    Whether the origin of severe hearing loss in Refsum's syndrome is caused by cochlear impairment or retrocochlear degeneration remains unclear. This case report aims to investigate hearing performance before and after cochlear implantation to shed light on this question. Also, identification of new mutations causing Refsum's syndrome would be helpful in generating additional means of diagnosis. A family of 4 individuals was subjected to genetic testing. Two siblings (56 and 61 years old) suffered from severe hearing and vision loss and received bilateral cochlear implants. Genetic analysis, audiological outcome, and clinical examinations were performed. One new mutation in the PHYH gene (c.768del63bp) causing Refsum's disease was found. Preoperative distortion product otoacoustic emissions (DPAOEs) were absent. Postoperative speech perception in Freiburger speech test was 100% for bisyllabic words and 85% (patient No. 1) and 65% (patient No. 2), respectively, for monosyllabic words. Five years after implantation, speech perception remained stable for bisyllabic words but showed decreasing capabilities for monosyllabic words. A new mutation causing Refsum's disease is presented. Cochlear implantation in case of severe hearing loss leads to an improvement in speech perception and should be recommended for patients with Refsum's disease, especially when the hearing loss is combined with a severe loss of vision. Decrease of speech perception in the long-term follow-up could indicate an additional retrocochlear degeneration.

  5. Suppressing the Morning Rise in Cortisol Impairs Free Recall

    Science.gov (United States)

    Rimmele, Ulrike; Meier, Flurina; Lange, Tanja; Born, Jan

    2010-01-01

    Elevated glucocorticoid levels impair memory retrieval. We investigated whether retrieval under naturally elevated glucocorticoid levels, i.e., during the morning rise in cortisol can be improved by suppressing cortisol. In a crossover study 16 men retrieved emotional and neutral texts and pictures (learned 3 d earlier) 30 min after morning…

  6. National Elevation Dataset

    Science.gov (United States)

    ,

    2002-01-01

    The National Elevation Dataset (NED) is a new raster product assembled by the U.S. Geological Survey. NED is designed to provide National elevation data in a seamless form with a consistent datum, elevation unit, and projection. Data corrections were made in the NED assembly process to minimize artifacts, perform edge matching, and fill sliver areas of missing data. NED has a resolution of one arc-second (approximately 30 meters) for the conterminous United States, Hawaii, Puerto Rico and the island territories and a resolution of two arc-seconds for Alaska. NED data sources have a variety of elevation units, horizontal datums, and map projections. In the NED assembly process the elevation values are converted to decimal meters as a consistent unit of measure, NAD83 is consistently used as horizontal datum, and all the data are recast in a geographic projection. Older DEM's produced by methods that are now obsolete have been filtered during the NED assembly process to minimize artifacts that are commonly found in data produced by these methods. Artifact removal greatly improves the quality of the slope, shaded-relief, and synthetic drainage information that can be derived from the elevation data. Figure 2 illustrates the results of this artifact removal filtering. NED processing also includes steps to adjust values where adjacent DEM's do not match well, and to fill sliver areas of missing data between DEM's. These processing steps ensure that NED has no void areas and artificial discontinuities have been minimized. The artifact removal filtering process does not eliminate all of the artifacts. In areas where the only available DEM is produced by older methods, then "striping" may still occur.

  7. Implants for orthodontic anchorage

    Science.gov (United States)

    Zheng, Xiaowen; Sun, Yannan; Zhang, Yimei; Cai, Ting; Sun, Feng; Lin, Jiuxiang

    2018-01-01

    Abstract Implantanchorage continues to receive much attention as an important orthodontic anchorage. Since the development of orthodontic implants, the scope of applications has continued to increase. Although multiple reviews detailing implants have been published, no comprehensive evaluations have been performed. Thus, the purpose of this study was to comprehensively evaluate the effects of implants based on data published in review articles. An electronic search of the Cochrane Library, Medline, Embase, Ebsco and Sicencedirect for reviews with “orthodontic” and “systematic review or meta analysis” in the title, abstract, keywords, or full text was performed. A subsequent manual search was then performed to identify reviews concerning orthodontic implants. A manual search of the orthodontic journals American Journal of Orthodontics and Dentofacial Orthopedics (AJODO), European Journal of Orthodontics (EJO), and Angle Othodontist was also performed. Such systematic reviews that evaluated the efficacy and safety of orthodontic implants were used to indicate success rates and molar movements. A total of 23 reviews were included in the analysis. The quality of each review was assessed using a measurement tool for Assessment of Multiple Systematic Reviews (AMSTAR), and the review chosen to summarize outcomes had a quality score of >6. Most reviews were less than moderate quality. Success rates of implants ranged in a broad scope, and movement of the maxillary first molar was superior with implants compared with traditional anchorage. PMID:29595673

  8. Maintenance in dental implants

    Directory of Open Access Journals (Sweden)

    Giselle Póvoa Gomes

    2008-01-01

    Full Text Available In implants, maintenance is a decisive factor for obtaining success when implant supported overdentures and dentures are used. The present stud presents, a clinical case of a patient, a 70 year-old white man, with a completely edentulous mandibular alveolar ridge, severe bone resorption with presence of basal bone only, and absence of vestibule. Initially, treatment consisted of the placement of a mandibular overdenture, supported on three implants in the anterior inter-foramen region, as the left implant was transfixed in the basal bone of 2 to 3 millimeters. Eleven years later, another two implants were placed in the anterior area and an immediate load was performed up to the first molars, for the placement of an implant supported fixed. Throughout the entire treatment, meticulous maintenance was carried out, with follow-up for fourteen years, interrupted by the patient’s death. From the third month after the opening the three implants initially placed, the presence of keratinized mucosa, definition of the vestibule, maturation of the alveolar ridge and bone formation in the mento region were observed. It was concluded that good planning, allied to mastery of the technique and adequate maintenance were the prerequisites necessary for obtaining favorable results, success of the present case, and for the patient to have a better quality of life.

  9. Nanotechnology for dental implants.

    Science.gov (United States)

    Tomsia, Antoni P; Lee, Janice S; Wegst, Ulrike G K; Saiz, Eduardo

    2013-01-01

    With the advent of nanotechnology, an opportunity exists for the engineering of new dental implant materials. Metallic dental implants have been successfully used for decades, but they have shortcomings related to osseointegration and mechanical properties that do not match those of bone. Absent the development of an entirely new class of materials, faster osseointegration of currently available dental implants can be accomplished by various surface modifications. To date, there is no consensus regarding the preferred method(s) of implant surface modification, and further development will be required before the ideal implant surface can be created, let alone become available for clinical use. Current approaches can generally be categorized into three areas: ceramic coatings, surface functionalization, and patterning on the micro- to nanoscale. The distinctions among these are imprecise, as some or all of these approaches can be combined to improve in vivo implant performance. These surface improvements have resulted in durable implants with a high percentage of success and long-term function. Nanotechnology has provided another set of opportunities for the manipulation of implant surfaces in its capacity to mimic the surface topography formed by extracellular matrix components of natural tissue. The possibilities introduced by nanotechnology now permit the tailoring of implant chemistry and structure with an unprecedented degree of control. For the first time, tools are available that can be used to manipulate the physicochemical environment and monitor key cellular events at the molecular level. These new tools and capabilities will result in faster bone formation, reduced healing time, and rapid recovery to function.

  10. Cortical visual impairment

    OpenAIRE

    Koželj, Urša

    2013-01-01

    In this thesis we discuss cortical visual impairment, diagnosis that is in the developed world in first place, since 20 percent of children with blindness or low vision are diagnosed with it. The objectives of the thesis are to define cortical visual impairment and the definition of characters suggestive of the cortical visual impairment as well as to search for causes that affect the growing diagnosis of cortical visual impairment. There are a lot of signs of cortical visual impairment. ...

  11. Interaktive tavler - interaktive elever

    DEFF Research Database (Denmark)

    Reusch, Charlotte F.; Otzen, Elsebeth

    Abstract, Poster-præsentation 13.-14. juni 2012, Pilotprojekt: Interaktive tavler – interaktive elever Lektor, cand. pæd., Elsebeth Otzen og Lektor, cand. mag., Charlotte Reusch, Institut for Skole og Læring, Læreruddannelsen, Professionshøjskolen Metropol, København Hvordan motiverer en interaktiv...... tavle lærere og elever? Hvad sker der mellem elev, stof og lærer, når læreren bliver i stand til at billedliggøre og dynamisere sine oplæg på tavlen? Bliver læreroplæg prioriteret? Bliver eleverne aktive, eller ender den interaktive tavle med blot at understøtte lærerens envejskommunikation til klassen......? Og hvad sker der mellem eleverne? Disse spørgsmål var igangsættende for arbejdet med pilotprojektet Interaktive tavler – interaktive elever, som blev afviklet i skoleåret 2010-2011. Projektet blev udført af en tværfaglig gruppe, bestående af lektorer i matematik, biologi og dansk i læreruddannelsen...

  12. Udeskole og elevers handlekompetence

    DEFF Research Database (Denmark)

    Breiting, Søren

    2011-01-01

    Elever elsker at komme væk fra undervisningen i skolen. Er det positivt eller negativt? Og hvad har betydning for, at eleverne får mest muligt ud af oplevelserne uden for skolen? Forskellige former for udeskole giver nogle oplagte muligheder, så eleverne udvikler sig som engagerede borgere i et...

  13. Interaktive tavler - interaktive elever

    DEFF Research Database (Denmark)

    Reusch, Charlotte; Otzen, Elsebeth

    Abstract, Poster-præsentation 13.-14. juni 2012, Pilotprojekt: Interaktive tavler ? interaktive elever Lektor, cand. pæd., Elsebeth Otzen og Lektor, cand. mag., Charlotte Reusch, Institut for Skole og Læring, Læreruddannelsen, Professionshøjskolen Metropol, København Hvordan motiverer en interaktiv...... tavle lærere og elever? Hvad sker der mellem elev, stof og lærer, når læreren bliver i stand til at billedliggøre og dynamisere sine oplæg på tavlen? Bliver læreroplæg prioriteret? Bliver eleverne aktive, eller ender den interaktive tavle med blot at understøtte lærerens envejskommunikation til klassen......? Og hvad sker der mellem eleverne? Disse spørgsmål var igangsættende for arbejdet med pilotprojektet Interaktive tavler ? interaktive elever, som blev afviklet i skoleåret 2010-2011. Projektet blev udført af en tværfaglig gruppe, bestående af lektorer i matematik, biologi og dansk i læreruddannelsen...

  14. Ion implantation for microelectronics

    International Nuclear Information System (INIS)

    Dearnaley, G.

    1977-01-01

    Ion implantation has proved to be a versatile and efficient means of producing microelectronic devices. This review summarizes the relevant physics and technology and assesses the advantages of the method. Examples are then given of widely different device structures which have been made by ion implantation. While most of the industrial application has been in silicon, good progress continues to be made in the more difficult field of compound semiconductors. Equipment designed for the industrial ion implantation of microelectronic devices is discussed briefly. (Auth.)

  15. Optimization of dental implantation

    Science.gov (United States)

    Dol, Aleksandr V.; Ivanov, Dmitriy V.

    2017-02-01

    Modern dentistry can not exist without dental implantation. This work is devoted to study of the "bone-implant" system and to optimization of dental prostheses installation. Modern non-invasive methods such as MRI an 3D-scanning as well as numerical calculations and 3D-prototyping allow to optimize all of stages of dental prosthetics. An integrated approach to the planning of implant surgery can significantly reduce the risk of complications in the first few days after treatment, and throughout the period of operation of the prosthesis.

  16. Female Offspring From Chronic Hyperandrogenemic Dams Exhibit Delayed Puberty and Impaired Ovarian Reserve.

    Science.gov (United States)

    Wang, Zhiqiang; Shen, Mingjie; Xue, Ping; DiVall, Sara A; Segars, James; Wu, Sheng

    2018-02-01

    Female offspring of many species exposed to high doses of androgens in utero experience endocrine dysfunction during adulthood. The phenotype of offspring from females with prepregnancy hyperandrogenemia and impaired ovulation, however, has not been examined. We developed a mouse model of hyperandrogenemia by implanting a low-dose dihydrotestosterone (DHT) pellet 15 days before conception. Female offspring born to dams with hyperandrogenemia (DHT daughters) had delayed puberty (P DHT (non-DHT daughters, PND37.5). Serum follicle-stimulating hormone (FSH) levels in the DHT daughters were fourfold higher (P DHT daughters (controls). DHT daughters showed an extended time in metestrus/diestrus and a shorter time in the proestrus/estrus phase compared with non-DHT daughters (P DHT daughters compared with non-DHT daughters (P DHT daughters compared with non-DHT daughters. Daughters from hyperandrogenemic females exhibited elevated prepubertal FSH levels, diminished ovarian response to superovulation, impaired estrous cyclicity, delayed onset of puberty, and reduced ovarian reserve, suggesting that fetal androgen exposure had lasting effects on female reproductive function. Copyright © 2018 Endocrine Society.

  17. Frontal subregions mediating Elevator Counting task performance.

    Science.gov (United States)

    MacPherson, Sarah E; Turner, Martha S; Bozzali, Marco; Cipolotti, Lisa; Shallice, Tim

    2010-10-01

    Deficits in sustained attention may lead to action slips in everyday life as irrelevant action sequences are inappropriately triggered internally or by the environment. While deficits in sustained attention have been associated with damage to the frontal lobes of the brain, little is known about the role of the frontal lobes in the Elevator Counting subtest of the Test of Everyday Attention. In the current study, 55 frontal patients subdivided into medial, orbital and lateral subgroups, 18 patients with posterior lesions and 82 healthy controls performed the Elevator Counting task. The results revealed that patients with medial and left lateral prefrontal lesions were significantly impaired on the task compared to healthy controls. Research suggests that patients with medial lesions are susceptible to competition from task irrelevant schema; whereas the left lateral group in the current study may fail to keep track of the tones already presented. Copyright © 2010 Elsevier Ltd. All rights reserved.

  18. Effects of silicone expanders and implants on echocardiographic image quality after breast reconstruction.

    Science.gov (United States)

    Pignatti, Marco; Mantovani, Francesca; Bertelli, Luca; Barbieri, Andrea; Pacchioni, Lucrezia; Loschi, Pietro; De Santis, Giorgio

    2013-08-01

    Use of silicone expanders and implants is the most common breast reconstruction technique after mastectomy. Postmastectomy patients often need echocardiographic monitoring of potential cardiotoxicity induced by cancer chemotherapy. The impairment of the echocardiographic acoustic window caused by silicone implants for breast augmentation has been reported. This study investigates whether the echocardiographic image quality was impaired in women reconstructed with silicone expanders and implants. The records of 44 consecutive women who underwent echocardiographic follow-up after breast reconstruction with expanders and implants at the authors' institution from January of 2000 to August of 2012 were reviewed. The population was divided into a study group (left or bilateral breast expanders/implants, n=30) and a control group (right breast expanders/implants, n=14). The impact of breast expanders/implants on echocardiographic image quality was tested (analysis of covariance model). Patients with a breast expander/implant (left or bilateral and right breast expanders/implants) were included. The mean volume of the breast devices was 353.2±125.5 cc. The quality of the echocardiographic images was good or sufficient in the control group; in the study group, it was judged as adequate in only 50 percent of cases (15 patients) and inadequate in the remaining 15 patients (pimplants in postmastectomy left breast reconstruction considerably reduce the image quality of echocardiography. This may have important clinical implications, given the need for periodic echocardiographic surveillance before and during chemotherapy. Therapeutic, III.

  19. The use of tungsten as a chronically implanted material

    Science.gov (United States)

    Shah Idil, A.; Donaldson, N.

    2018-04-01

    This review paper shows that tungsten should not generally be used as a chronically implanted material. The metal has a long implant history, from neuroscience, vascular medicine, radiography, orthopaedics, prosthodontics, and various other fields, primarily as a result of its high density, radiopacity, tensile strength, and yield point. However, a crucial material criterion for chronically implanted metals is their long-term resistance to corrosion in body fluids, either by inherently noble metallic surfaces, or by protective passivation layers of metal oxide. The latter is often assumed for elemental tungsten, with references to its ‘inertness’ and ‘stability’ common in the literature. This review argues that in the body, metallic tungsten fails this criterion, and will eventually dissolve into the soluble hexavalent form W6+, typically represented by the orthotungstate WO42- (monomeric tungstate) anion. This paper outlines the metal’s unfavourable corrosion thermodynamics in the human physiological environment, the chemical pathways to either metallic or metal oxide dissolution, the rate-limiting steps, and the corrosion-accelerating effects of reactive oxidising species that the immune system produces post-implantation. Multiple examples of implant corrosion have been reported, with failure by dissolution to varying extents up to total loss, with associated emission of tungstate ions and elevated blood serum levels measured. The possible toxicity of these corrosion products has also been explored. As the field of medical implants grows and designers explore novel solutions to medical implant problems, the authors recommend the use of alternative materials.

  20. Tribological studies of ion-implanted steel constituents

    International Nuclear Information System (INIS)

    Wei, Ronghau.

    1990-01-01

    Tribological properties of ion-implanted ferrite and austenite were studied systematically using a unique oscillating pin-on-disc wear tester. Results show that nitrogen implantation at elevated temperatures to high doses dramatically improves the adhesive wear resistance of ferrite and the critical load at which the adhesive wear mechanism changes from mild to severe for austenite. The wear resistance of nitrogen-implanted ferrite is determined by the nitride formed. Extremely hard solid solutions of nitrogen develop on the implanted austenite surfaces and induce three orders of magnitude reductions in wear rates. The implantation conditions that should be used to produce deep, wear-resistant layers for both steels are discussed in detail. Oscillating pin-on-disc wear tests demonstrate that nitrogen does not diffuse during the wearing process although tests conducted using conventional fixed pin-on-disc test equipment could erroneously suggest this occurs. Taken together, the results show that high-dose-rate implantation at low energies yields very-high-quality implanted surfaces at low cost

  1. Breast Reconstruction with Implants

    Science.gov (United States)

    ... your surgical options and discuss the advantages and disadvantages of implant-based reconstruction, and may show you ... Policy Notice of Privacy Practices Notice of Nondiscrimination Advertising Mayo Clinic is a not-for-profit organization ...

  2. Ion Implantation of Polymers

    DEFF Research Database (Denmark)

    Popok, Vladimir

    2012-01-01

    The current paper presents a state-of-the-art review in the field of ion implantation of polymers. Numerous published studies of polymers modified by ion beams are analysed. General aspects of ion stopping, latent track formation and changes of structure and composition of organic materials...... are discussed. Related to that, the effects of radiothermolysis, degassing and carbonisation are considered. Specificity of depth distributions of implanted into polymers impurities is analysed and the case of high-fluence implantation is emphasised. Within rather broad topic of ion bombardment, the focus...... is put on the low-energy implantation of metal ions causing the nucleation and growth of nanoparticles in the shallow polymer layers. Electrical, optical and magnetic properties of metal/polymer composites are under the discussion and the approaches towards practical applications are overviewed....

  3. Precipitation processes in implanted materials

    International Nuclear Information System (INIS)

    Borders, J.A.

    1978-01-01

    Ion implantation is a nonequilibrium process. It is possible to implant materials with impurities to concentration levels which exceed the solid solubilities. The return of the system to thermodynamic equilibrium is often accomplished by precipitation of the implanted species or a compound involving atoms of both the host and the implanted species. This may involve long time scales when taking place at room temperature or it may take place during the implantation

  4. Ion implantation for semiconductors

    International Nuclear Information System (INIS)

    Grey-Morgan, T.

    1995-01-01

    Full text: Over the past two decades, thousands of particle accelerators have been used to implant foreign atoms like boron, phosphorus and arsenic into silicon crystal wafers to produce special embedded layers for manufacturing semiconductor devices. Depending on the device required, the atomic species, the depth of implant and doping levels are the main parameters for the implantation process; the selection and parameter control is totally automated. The depth of the implant, usually less than 1 micron, is determined by the ion energy, which can be varied between 2 and 600 keV. The ion beam is extracted from a Freeman or Bernas type ion source and accelerated to 60 keV before mass analysis. For higher beam energies postacceleration is applied up to 200 keV and even higher energies can be achieved by mass selecting multiplycharged ions, but with a corresponding reduction in beam output. Depending on the device to be manufactured, doping levels can range from 10 10 to 10 15 atoms/cm 2 and are controlled by implanter beam currents in the range up to 30mA; continuous process monitoring ensures uniformity across the wafer of better than 1 % . As semiconductor devices get smaller, additional sophistication is required in the design of the implanter. The silicon wafers charge electrically during implantation and this charge must be dissipated continuously to reduce the electrical stress in the device and avoid destructive electrical breakdown. Electron flood guns produce low energy electrons (below 10 electronvolts) to neutralize positive charge buildup and implanter design must ensure minimum contamination by other isotopic species and ensure low internal sputter rates. The pace of technology in the semiconductor industry is such that implanters are being built now for 256 Megabit circuits but which are only likely to be widely available five years from now. Several specialist companies manufacture implanter systems, each costing around US$5 million, depending on the

  5. Device-based local delivery of siRNA against mammalian target of rapamycin (mTOR) in a murine subcutaneous implant model to inhibit fibrous encapsulation

    OpenAIRE

    Takahashi, Hironobu; Wang, Yuwei; Grainger, David W.

    2010-01-01

    Fibrous encapsulation of surgically implant devices is associated with elevated proliferation and activation of fibroblasts in tissues surrounding these implants, frequently causing foreign body complications. Here we test the hypothesis that inhibition of the expression of mammalian target of rapamycin (mTOR) in fibroblasts can mitigate the soft tissue implant foreign body response by suppressing fibrotic responses around implants. In this study, mTOR was knocked down using small interfering...

  6. Quantitative ion implantation

    International Nuclear Information System (INIS)

    Gries, W.H.

    1976-06-01

    This is a report of the study of the implantation of heavy ions at medium keV-energies into electrically conducting mono-elemental solids, at ion doses too small to cause significant loss of the implanted ions by resputtering. The study has been undertaken to investigate the possibility of accurate portioning of matter in submicrogram quantities, with some specific applications in mind. The problem is extensively investigated both on a theoretical level and in practice. A mathematical model is developed for calculating the loss of implanted ions by resputtering as a function of the implanted ion dose and the sputtering yield. Numerical data are produced therefrom which permit a good order-of-magnitude estimate of the loss for any ion/solid combination in which the ions are heavier than the solid atoms, and for any ion energy from 10 to 300 keV. The implanted ion dose is measured by integration of the ion beam current, and equipment and techniques are described which make possible the accurate integration of an ion current in an electromagnetic isotope separator. The methods are applied to two sample cases, one being a stable isotope, the other a radioisotope. In both cases independent methods are used to show that the implantation is indeed quantitative, as predicted. At the same time the sample cases are used to demonstrate two possible applications for quantitative ion implantation, viz. firstly for the manufacture of calibration standards for instrumental micromethods of elemental trace analysis in metals, and secondly for the determination of the half-lives of long-lived radioisotopes by a specific activity method. It is concluded that the present study has advanced quantitative ion implantation to the state where it can be successfully applied to the solution of problems in other fields

  7. Ion implantation - an introduction

    International Nuclear Information System (INIS)

    Townsend, P.D.

    1986-01-01

    Ion implantation is a widely used technique with a literature that covers semiconductor production, surface treatments of steels, corrosion resistance, catalysis and integrated optics. This brief introduction outlines advantages of the technique, some aspects of the underlying physics and examples of current applications. Ion implantation is already an essential part of semiconductor technology while in many other areas it is still in an early stage of development. The future scope of the subject is discussed. (author)

  8. External ear anomalies and hearing impairment in Noonan Syndrome.

    Science.gov (United States)

    van Trier, Dorothée C; van Nierop, Josephine; Draaisma, Jos M Th; van der Burgt, Ineke; Kunst, Henricus; Croonen, Ellen A; Admiraal, Ronald J C

    2015-06-01

    This is the first cohort in which hearing impairment and external ear anomalies in Noonan Syndrome are described extensively. Retrospective analysis of the otorhinolaryngological and clinical genetic data from 97 Noonan Syndrome (NS) patients. Forty-four NS patients were seen by an otorhinolaryngologist for the analysis of hearing impairment. In our cohort 80 of the 97 patients were genetically tested. In 71 of these mutations were found: in 48 patients a mutation in PTPN11, in 10 patients in SOS1, in 5 patients in SHOC2, in 5 patients in RAF1, in 1 patient in MAP2K2, in 1 patient in KRAS and in 1 patient in A2ML1. External ear anomalies were reported in 75 NS patients (77%). In 69 patients the ears were low-set, 28 patients had posteriorly rotated ears, 14 patients showed protruding ears and 18 had thickened helices. Hearing impairment was detected in 34 NS patients. Nine patients had sensorineural hearing impairment, two a permanent conductive hearing impairment, two other patients had mixed hearing impairment and 20 patients had conductive hearing impairment in the past, caused by otitis media with effusion. Their temporary conductive hearing impairment resolved between the ages of 2 and 18 years. Sensorineural hearing impairment varied between mild high-frequency hearing impairment and profound (uni- and bilateral) hearing impairment and was progressive in three patients. Four NS patients received cochlear implants for their severe sensorineural hearing impairment. The cohort is small for genotype-phenotype correlations, but sensorineural hearing impairment, especially the bilateral severe hearing impairment, was only seen in patients with a PTPN11 mutation. NS is characterized by dysmorphic external ear anomalies and both sensorineural and conductive hearing impairment. Audiological examinations are recommended in all patients with Noonan Syndrome. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. Contraceptive implants: current perspectives

    Directory of Open Access Journals (Sweden)

    Rowlands S

    2014-09-01

    Full Text Available Sam Rowlands,1,2 Stephen Searle3 1Centre of Postgraduate Medical Research and Education, School of Health and Social Care, Bournemouth University, Bournemouth, United Kingdom; 2Dorset HealthCare, Bournemouth, United Kingdom; 3Sexual Health Services, Chesterfield, United KingdomAbstract: Progestin-only contraceptive implants are a highly cost-effective form of long-acting reversible contraception. They are the most effective reversible contraceptives and are of a similar effectiveness to sterilization. Pregnancies are rare in women using this method of contraception, and those that do occur must be fully investigated, with an ultrasound scan of the arm and serum etonogestrel level if the implant cannot be located. There are very few contraindications to use of implants, and they have an excellent safety profile. Both acceptability and continuation with the method are high. Noncontraceptive benefits include improvements in dysmenorrhea, ovulatory pain, and endometriosis. Problematic bleeding is a relatively common adverse effect that must be covered in preinsertion information-giving and supported adequately if it occurs. Recognized training for both insertion and removal should be undertaken. Care needs to be taken at both insertion and removal to avoid neurovascular injury. Implants should always be palpable; if they are not, noninsertion should be assumed until disproven. Etonogestrel implants are now radiopaque, which aids localization. Anticipated difficult removals should be performed by specially trained experts. Keywords: contraceptive, subdermal implant, etonogestrel, levonorgestrel, progestin-only, long-acting reversible contraception

  10. Anodized dental implant surface

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Mishra

    2017-01-01

    Full Text Available Purpose: Anodized implants with moderately rough surface were introduced around 2000. Whether these implants enhanced biologic effect to improve the environment for better osseointegration was unclear. The purpose of this article was to review the literature available on anodized surface in terms of their clinical success rate and bone response in patients till now. Materials and Methods: A broad electronic search of MEDLINE and PubMed databases was performed. A focus was made on peer-reviewed dental journals. Only articles related to anodized implants were included. Both animal and human studies were included. Results: The initial search of articles resulted in 581 articles on anodized implants. The initial screening of titles and abstracts resulted in 112 full-text papers; 40 animal studies, 16 studies on cell adhesion and bacterial adhesion onto anodized surfaced implants, and 47 human studies were included. Nine studies, which do not fulfill the inclusion criteria, were excluded. Conclusions: The long-term studies on anodized surface implants do favor the surface, but in most of the studies, anodized surface is compared with that of machined surface, but not with other surfaces commercially available. Anodized surface in terms of clinical success rate in cases of compromised bone and immediately extracted sockets has shown favorable success.

  11. Plasma source ion implantation

    International Nuclear Information System (INIS)

    Conrad, J.R.; Forest, C.

    1986-01-01

    The authors' technique allows the ion implantation to be performed directly within the ion source at higher currents without ion beam extraction and transport. The potential benefits include greatly increased production rates (factors of 10-1000) and the ability to implant non-planar targets without rastering or shadowing. The technique eliminates the ion extractor grid set, beam raster equipment, drift space and target manipulator equipment. The target to be implanted is placed directly within the plasma source and is biased to a large negative potential so that plasma ions gain energy as they accelerate through the potential drop across the sheath that forms at the plasma boundary. Because the sheath surrounds the target on all sides, all surfaces of the target are implanted without the necessity to raster the beam or to rotate the target. The authors have succeeded in implanting nitrogen ions in a silicon target to the depths and concentrations required for surface treatment of materials like stainless steel and titanium alloys. They have performed ESCA measurements of the penetration depth profile of a silicon target that was biased to 30 kV in a nitrogen discharge plasma. Nitrogen ions were implanted to a depth of 700A at a peak concentration of 30% atomic. The measured profile is quite similar to a previously obtained profile in titanium targets with conventional techniques

  12. Clinical application of single-tooth replacement with ankylos implant system

    International Nuclear Information System (INIS)

    Yang Xu; Liu Xue; Zhang Heng; Deng Yan; Guo Zhaozhong; Zhang Yufeng

    2011-01-01

    Objective: To evaluate the clinical effects of Ankylos implant system to restore the loss of single-tooth. Methods: 90 cases with loss of single-tooth were selected and treated with routinely two-stage surgery. When the patients presented with deficient alveolar ridge, guided bone regeneration (GBR), osteotome sinus floor elevation, lateral antrostomy surgery with simultaneous placement of implant were applied. They were restored with platinum ceramic crown. All the implants were followed up, and the records were kept about stability of the implant and abutment, the status of surrounding soft tissue, sealability of implant abutment junction and the marginal bone lossing through X-ray checking,and satisfaction of the patients to mastication and aspect of the restorations. The follow-up time was 1-2.5 years. Results: Among the cases,one case had peri-implant inflammation, and one case had porcelain dropped. No loosening occurred in the other implants and abuments. Implant abutment junction was sealed well. The marginal bone loss 1 year after final restoration was less than 1 mm. Soft tissue surrounding implants was healthy. The satisfaction rate was 98.9% (89/90). According to standard of implant success, 88 cases were successful, the 2.5-year cumulative success rate was 97.8%, 2 cases failed, and the failure rate was 2.2 %. Conclusion: A satisfactory treatment effects could be gotten by using Ankylos implant system to restore the loss of single-tooth. (authors)

  13. Short dental implants: an emerging concept in implant treatment.

    Science.gov (United States)

    Al-Hashedi, Ashwaq Ali; Taiyeb Ali, Tara Bai; Yunus, Norsiah

    2014-06-01

    Short implants have been advocated as a treatment option in many clinical situations where the use of conventional implants is limited. This review outlines the effectiveness and clinical outcomes of using short implants as a valid treatment option in the rehabilitation of edentulous atrophic alveolar ridges. Initially, an electronic search was performed on the following databases: Medline, PubMed, Embase, Cochrane Database of Systematic Reviews, and DARE using key words from January 1990 until May 2012. An additional hand search was included for the relevant articles in the following journals: International Journal of Oral and Maxillofacial Implants, Clinical Oral Implants Research, Journal of Clinical Periodontology, International Journal of Periodontics, Journal of Periodontology, and Clinical Implant Dentistry and Related Research. Any relevant papers from the journals' references were hand searched. Articles were included if they provided detailed data on implant length, reported survival rates, mentioned measures for implant failure, were in the English language, involved human subjects, and researched implants inserted in healed atrophic ridges with a follow-up period of at least 1 year after implant-prosthesis loading. Short implants demonstrated a high rate of success in the replacement of missing teeth in especially atrophic alveolar ridges. The advanced technology and improvement of the implant surfaces have encouraged the success of short implants to a comparable level to that of standard implants. However, further randomized controlled clinical trials and prospective studies with longer follow-up periods are needed.

  14. Skuldertesten "Kombineret Elevation"

    DEFF Research Database (Denmark)

    Clausen, Mikkel Bek; Overkær, Brian

    2010-01-01

    Formål: At udarbejde en testprotokol for testen Kombineret Elevation (KE) og undersøge test-retest variationen ved test af elite svømmere, samt diskutere testens relevans og validitet. Materiale og Metode: 9 elite og 10 sub-elite svømmere, heraf var 11 mænd og 8 kvinder, gennemførte testen KE 2...

  15. Comparison of Immediate With Delayed Stenting Using the Minimalist Immediate Mechanical Intervention Approach in Acute ST-Segment-Elevation Myocardial Infarction: The MIMI Study.

    Science.gov (United States)

    Belle, Loic; Motreff, Pascal; Mangin, Lionel; Rangé, Grégoire; Marcaggi, Xavier; Marie, Antoine; Ferrier, Nadine; Dubreuil, Olivier; Zemour, Gilles; Souteyrand, Géraud; Caussin, Christophe; Amabile, Nicolas; Isaaz, Karl; Dauphin, Raphael; Koning, René; Robin, Christophe; Faurie, Benjamin; Bonello, Laurent; Champin, Stanislas; Delhaye, Cédric; Cuilleret, François; Mewton, Nathan; Genty, Céline; Viallon, Magalie; Bosson, Jean Luc; Croisille, Pierre

    2016-03-01

    Delayed stent implantation after restoration of normal epicardial flow by a minimalist immediate mechanical intervention aims to decrease the rate of distal embolization and impaired myocardial reperfusion after percutaneous coronary intervention. We sought to confirm whether a delayed stenting (DS) approach (24-48 hours) improves myocardial reperfusion, versus immediate stenting, in patients with acute ST-segment-elevation myocardial infarction undergoing primary percutaneous coronary intervention. In the prospective, randomized, open-label minimalist immediate mechanical intervention (MIMI) trial, patients (n=140) with ST-segment-elevation myocardial infarction ≤12 hours were randomized to immediate stenting (n=73) or DS (n=67) after Thrombolysis In Myocardial Infarction 3 flow restoration by thrombus aspiration. Patients in the DS group underwent a second coronary arteriography for stent implantation a median of 36 hours (interquartile range 29-46) after randomization. The primary end point was microvascular obstruction (% left ventricular mass) on cardiac magnetic resonance imaging performed 5 days (interquartile range 4-6) after the first procedure. There was a nonsignificant trend toward lower microvascular obstruction in the immediate stenting group compared with DS group (1.88% versus 3.96%; P=0.051), which became significant after adjustment for the area at risk (P=0.049). Median infarct weight, left ventricular ejection fraction, and infarct size did not differ between groups. No difference in 6-month outcomes was apparent for the rate of major cardiovascular and cerebral events. The present findings do not support a strategy of DS versus immediate stenting in patients with ST-segment-elevation infarction undergoing primary percutaneous coronary intervention and even suggested a deleterious effect of DS on microvascular obstruction size. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01360242. © 2016 American Heart Association, Inc.

  16. Effect of radial head implant shape on joint contact area and location during static loading.

    Science.gov (United States)

    Shannon, Hannah L; Deluce, Simon R; Lalone, Emily A; Willing, Ryan; King, Graham J W; Johnson, James A

    2015-04-01

    To examine the effect of implant shape on radiocapitellar joint contact area and location in vitro. We used 8 fresh-frozen cadaveric upper extremities. An elbow loading simulator examined joint contact in pronation, neutral rotation, and supination with the elbow at 90° flexion. Muscle tendons were attached to pneumatic actuators to allow for computer-controlled loading to achieve the desired forearm rotation. We performed testing with the native radial head, an axisymmetric implant, a reverse-engineered patient-specific implant, and a population-based quasi-anatomic implant. Implants were inserted using computer navigation. Contact area and location were quantified using a casting technique. We found no significant difference between contact locations for the native radial head and the 3 implants. All of the implants had a contact area lower than the native radial head; however, only the axisymmetric implant was significantly different. There was no significant difference in contact area between implant shapes. The similar contact areas and locations of the 3 implant designs suggest that the shape of the implant may not be important with respect to radiocapitellar joint contact mechanics when placed optimally using computer navigation. Further work is needed to explore the sensitivity of radial head implant malpositioning on articular contact. The lower contact area of the radial head implants relative to the native radial head is similar to previous benchtop studies and is likely the result of the greater stiffness of the implant. Radial head implant shape does not appear to have a pronounced influence on articular contact, and both axisymmetric and anatomic metal designs result in elevated cartilage stress relative to the intact state. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  17. Mild Cognitive Impairment (MCI)

    Science.gov (United States)

    Mild cognitive impairment (MCI) Overview Mild cognitive impairment (MCI) is an intermediate stage between the expected cognitive decline of normal aging and the more-serious decline of dementia. It ...

  18. Oral rehabilitation of segmental mandibulectomy patient with osseointegrated dental implant

    Directory of Open Access Journals (Sweden)

    Archana Singh

    2014-01-01

    Full Text Available Surgical management of oral cancer lesions results in explicit aesthetic and functional disfigurement, including facial deformity, loss of hard and soft tissue, impaired speech, swallowing and mastication, which modify the patient′s self-image and quality-of-life. Recent advances in head and neck reconstruction techniques and dental implant based prosthetic rehabilitation may significantly improve the quality-of-life and self-esteem for such post-surgery patients. This clinical report describes rehabilitation of oral cancer patient having segmental mandibulectomy with implant-supported fixed partial denture.

  19. Adapting for Impaired Patrons.

    Science.gov (United States)

    Schuyler, Michael

    1999-01-01

    Describes how a library, with an MCI Corporation grant, approached the process of setting up computers for the visually impaired. Discusses preparations, which included hiring a visually-impaired user as a consultant and contacting the VIP (Visually Impaired Persons) group; equipment; problems with the graphical user interface; and training.…

  20. A spider elevator

    Energy Technology Data Exchange (ETDEWEB)

    Butylkin, A.V.; Butylkin, V.A.; Izosimov, A.M.

    1983-01-01

    A spider elevator is proposed which contains a body, a wedge clamp with wedges hinged to each other, a subassembly for holding the wedge clamp in the open and closed positions and a mechanism for changing the wedge clamp, which is made in the form of levers with ears for cleats and installed in the body with the capability of turning. To increase reliability in the operational mode through using the external force for clamping the pipe, the free ends of the levers are hinged with the body by a power cylinder.

  1. Elevator Control Strategies

    OpenAIRE

    Ceder, Frederick; Nordin, Alexandra

    2013-01-01

    The purpose of this essay is to investigate if it is eective to switch strategies for elevators during one day in an oce building. This essay describes some of the strategies in use today, followed by a comparison and analysis of two of the strategies described. We have also implemented optimizations to one of these strategies. From our test results we can conclude that our optimized strategy worked and produced better results on average waiting time and total traveling time than the two stra...

  2. [Bilateral cochlear implants].

    Science.gov (United States)

    Müller, J

    2017-07-01

    Cochlear implants (CI) are standard for the hearing rehabilitation of severe to profound deafness. Nowadays, if bilaterally indicated, bilateral implantation is usually recommended (in accordance with German guidelines). Bilateral implantation enables better speech discrimination in quiet and in noise, and restores directional and spatial hearing. Children with bilateral CI are able to undergo hearing-based hearing and speech development. Within the scope of their individual possibilities, bilaterally implanted children develop faster than children with unilateral CI and attain, e.g., a larger vocabulary within a certain time interval. Only bilateral implantation allows "binaural hearing," with all the benefits that people with normal hearing profit from, namely: better speech discrimination in quiet and in noise, as well as directional and spatial hearing. Naturally, the developments take time. Binaural CI users benefit from the same effects as normal hearing persons: head shadow effect, squelch effect, and summation and redundancy effects. Sequential CI fitting is not necessarily disadvantageous-both simultaneously and sequentially fitted patients benefit in a similar way. For children, earliest possible fitting and shortest possible interval between the two surgeries seems to positively influence the outcome if bilateral CI are indicated.

  3. Elevated placental adenosine signaling contributes to the pathogenesis of preeclampsia.

    Science.gov (United States)

    Iriyama, Takayuki; Sun, Kaiqi; Parchim, Nicholas F; Li, Jessica; Zhao, Cheng; Song, Anren; Hart, Laura A; Blackwell, Sean C; Sibai, Baha M; Chan, Lee-Nien L; Chan, Teh-Sheng; Hicks, M John; Blackburn, Michael R; Kellems, Rodney E; Xia, Yang

    2015-02-24

    Preeclampsia is a prevalent hypertensive disorder of pregnancy and a leading cause of maternal and neonatal morbidity and mortality worldwide. This pathogenic condition is speculated to be caused by placental abnormalities that contribute to the maternal syndrome. However, the specific factors and signaling pathways that lead to impaired placentas and maternal disease development remain elusive. Using 2 independent animal models of preeclampsia (genetically engineered pregnant mice with elevated adenosine exclusively in placentas and a pathogenic autoantibody-induced preeclampsia mouse model), we demonstrated that chronically elevated placental adenosine was sufficient to induce hallmark features of preeclampsia, including hypertension, proteinuria, small fetuses, and impaired placental vasculature. Genetic and pharmacological approaches revealed that elevated placental adenosine coupled with excessive A₂B adenosine receptor (ADORA2B) signaling contributed to the development of these features of preeclampsia. Mechanistically, we provided both human and mouse evidence that elevated placental CD73 is a key enzyme causing increased placental adenosine, thereby contributing to preeclampsia. We determined that elevated placental adenosine signaling is a previously unrecognized pathogenic factor for preeclampsia. Moreover, our findings revealed the molecular basis underlying the elevation of placental adenosine and the detrimental role of excess placental adenosine in the pathophysiology of preeclampsia, and thereby, we highlight novel therapeutic targets. © 2014 American Heart Association, Inc.

  4. Psychological intervention following implantation of an implantable defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Sears, Samuel F

    2007-01-01

    The medical benefits of the implantable cardioverter defibrillator (ICD) are unequivocal, but a subgroup of patients experiences emotional difficulties following implantation. For this subgroup, some form of psychological intervention may be warranted. This review provides an overview of current ...

  5. Influence of cochlear implantation on peripheral vestibular receptor function.

    Science.gov (United States)

    Krause, Eike; Louza, Julia P R; Wechtenbruch, Juliane; Gürkov, Robert

    2010-06-01

    The objectives of this study were 1) to assess the influence of a cochlear implantation on peripheral vestibular receptor function in the inner ear in the implant and in the nonimplant side, and 2) to analyze a possible correlation with resulting vertigo symptoms. Prospective clinical study. Cochlear implant center at tertiary referral hospital. A total of 32 patients, aged 15 to 83 years, undergoing cochlear implantation were assessed pre- and postoperatively for caloric horizontal semicircular canal response and vestibular-evoked myogenic potentials of the sacculus, and postoperatively for subjective vertigo symptoms. Patients with vertigo were compared with patients without symptoms with regard to the findings of the vestibular function tests. Cochlear implantation represents a significant risk factor for horizontal semicircular canal impairment (P 0.05). Cochlear implantation is a relevant risk factor for damage of peripheral vestibular receptor function. Therefore, preservation not only of residual hearing function but also of vestibular function should be aimed for, by using minimally invasive surgical techniques. Copyright 2010 American Academy of Otolaryngology-Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.

  6. Management of peri-implantitis

    Directory of Open Access Journals (Sweden)

    Jayachandran Prathapachandran

    2012-01-01

    Full Text Available Peri-implantitis is a site-specific infectious disease that causes an inflammatory process in soft tissues, and bone loss around an osseointegrated implant in function. The etiology of the implant infection is conditioned by the status of the tissue surrounding the implant, implant design, degree of roughness, external morphology, and excessive mechanical load. The microorganisms most commonly associated with implant failure are spirochetes and mobile forms of Gram-negative anaerobes, unless the origin is the result of simple mechanical overload. Diagnosis is based on changes of color in the gingiva, bleeding and probing depth of peri-implant pockets, suppuration, X-ray, and gradual loss of bone height around the tooth. Treatment will differ depending upon whether it is a case of peri-implant mucositis or peri-implantitis. The management of implant infection should be focused on the control of infection, the detoxification of the implant surface, and regeneration of the alveolar bone. This review article deals with the various treatment options in the management of peri-implantitis. The article also gives a brief description of the etiopathogenesis, clinical features, and diagnosis of peri-implantitis.

  7. Development of a CMOS process using high energy ion implantation

    International Nuclear Information System (INIS)

    Stolmeijer, A.

    1986-01-01

    The main interest of this thesis is the use of complementary metal oxide semiconductors (CMOS) in electronic technology. Problems in developing a CMOS process are mostly related to the isolation well of p-n junctions. It is shown that by using high energy ion implantation, it is possible to reduce lateral dimensions to obtain a rather high packing density. High energy ion implantation is also presented as a means of simplifying CMOS processing, since extended processing steps at elevated temperatures are superfluous. Process development is also simplified. (Auth.)

  8. Hearing Preservation in Cochlear Implant Surgery

    Directory of Open Access Journals (Sweden)

    Priscila Carvalho Miranda

    2014-01-01

    Full Text Available In the past, it was thought that hearing loss patients with residual low-frequency hearing would not be good candidates for cochlear implantation since insertion was expected to induce inner ear trauma. Recent advances in electrode design and surgical techniques have made the preservation of residual low-frequency hearing achievable and desirable. The importance of preserving residual low-frequency hearing cannot be underestimated in light of the added benefit of hearing in noisy atmospheres and in music quality. The concept of electrical and acoustic stimulation involves electrically stimulating the nonfunctional, high-frequency region of the cochlea with a cochlear implant and applying a hearing aid in the low-frequency range. The principle of preserving low-frequency hearing by a “soft surgery” cochlear implantation could also be useful to the population of children who might profit from regenerative hair cell therapy in the future. Main aspects of low-frequency hearing preservation surgery are discussed in this review: its brief history, electrode design, principles and advantages of electric-acoustic stimulation, surgical technique, and further implications of this new treatment possibility for hearing impaired patients.

  9. Automatic pipe elevator

    Energy Technology Data Exchange (ETDEWEB)

    Haney, K.M.; Willis, C.A.

    1987-03-17

    This patent describes an elevator adapted for use with a power swivel for supporting a drilling or production tubular, the elevator comprising: at least two jaws, each jaw having a clamping surface; a connector member for supporting the jaws, the connector member comprising an upper end, a lower end, means for coupling the upper end to the power swivel, means for coupling the lower end to a tubular. The member also comprises means for defining a passageway extending from the upper end to the lower end through the connector member to allow drilling mud to be passed from the power swivel through the bore, into the tubular; and linkage means mounted between the connector member and the jaws for coupling the jaws to the connector member and for maintaining the clamping surfaces of the jaws in clamping engagement with the tubular when the connector member and the tubular are urged apart relative to one another. The linkage means is configured such that the force by which the clamping surfaces clamp the tubular increases as the force urging the connector member and the tubular apart increases.

  10. Parkinson's disease associated with impaired oxidative phosphorylation

    International Nuclear Information System (INIS)

    Finsterer, J.; Jarius, C.; Baumgartner, M.

    2001-01-01

    Parkinson's disease may be due to primary or secondary oxidative phosphorylation (OXPHOS) defects. In a 76-year-old man with Parkinson's disease since 1992, slightly but recurrently elevated creatine phosphokinase, recurrently elevated blood glucose, thickening of the left ventricular myocardium, bifascicular block and hypacusis were found. Cerebral MRI showed atrophy, periventricular demyelination, multiple, disseminated, supra- and infratentorial lacunas, and haemosiderin deposits in both posterior horns. Muscle biopsy showed typical features of an OXPHOS defect. Whether the association of Parkinson's disease and impaired OXPHOS was causative or coincidental remains unknown. Possibly, the mitochondrial defect acted as an additional risk factor for Parkinson's disease or the OXPHOS defect worsened the preexisting neurological impairments by a cumulative or synergistic mechanism. In conclusion, this case shows that Parkinson's disease may be associated with a mitochondrially or nuclearly encoded OXPHOS defect, manifesting as hypacusis, myopathy, axonal polyneuropathy, cardiomyopathy and recurrent subclinical ischaemic strokes and haemorrhages. (orig.)

  11. Elevation data for floodplain mapping

    National Research Council Canada - National Science Library

    Committee on Floodplain Mapping Technologies; National Research Council; Division on Earth and Life Studies; National Research Council

    2007-01-01

    .... Elevation Data for Floodplain Mapping shows that there is sufficient two-dimensional base map imagery to meet FEMA's flood map modernization goals, but that the three-dimensional base elevation data...

  12. Ion implantation control system

    International Nuclear Information System (INIS)

    Gault, R. B.; Keutzer, L. L.

    1985-01-01

    A control system is disclosed for an ion implantation system of the type in which the wafers to be implanted are mounted around the periphery of a disk which rotates and also moves in a radial direction relative to an ion beam to expose successive sections of each wafer to the radiation. The control system senses beam current which passes through one or more apertures in the disk and is collected by a Faraday cup. This current is integrated to obtain a measure of charge which is compared with a calculated value based upon the desired ion dosage and other parameters. The resultant controls the number of incremental steps the rotating disk moves radially to expose the adjacent sections of each wafer. This process is continued usually with two or more traverses until the entire surface of each wafer has been implanted with the proper ion dosage

  13. Implantation for tribological applications

    International Nuclear Information System (INIS)

    Leutenecker, R.; Cao-Minh, U.; Overbeck, R.

    1992-08-01

    Empirical results on the strength enhancement of steels by N- and B-implantation should be explained from a materials science point of view. The methods applied were X-ray diffractometry and element depth profiling. The investigations of N-implanted steels focussed on the nitride formation in selected model materials and, with respect to applications, in: X90 CrMoV and S 6-5-2 tool steels, austenite X10 CrNiTi189 as well as in hard chromium plates. Main topic in B-implanted steels were the transformations: crystalline Fe-phase - amorphous Fe-B-phase - crystalline boride phases. The result is an improvement in process control by first an insight into the strength enhancing mechanisms and second in into their generation depending on the materials microstructure and the process parameter. (orig.). 101 figs., 16 tabs., 15 refs [de

  14. Dental implants: A review.

    Science.gov (United States)

    Guillaume, B

    2016-12-01

    A high number of patients have one or more missing tooth and it is estimated that one in four American subjects over the age of 74 have lost all their natural teeth. Many options exist to replace missing teeth but dental implants have become one of the most used biomaterial to replace one (or more) missing tooth over the last decades. Contemporary dental implants made with titanium have been proven safe and effective in large series of patients. This review considers the main historical facts concerned with dental implants and present the different critical factors that will ensure a good osseo-integration that will ensure a stable prosthesis anchorage. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  15. Memory Impairment in Children with Language Impairment

    Science.gov (United States)

    Baird, Gillian; Dworzynski, Katharina; Slonims, Vicky; Simonoff, Emily

    2010-01-01

    Aim: The aim of this study was to assess whether any memory impairment co-occurring with language impairment is global, affecting both verbal and visual domains, or domain specific. Method: Visual and verbal memory, learning, and processing speed were assessed in children aged 6 years to 16 years 11 months (mean 9y 9m, SD 2y 6mo) with current,…

  16. Tribology of implantation bilayers

    International Nuclear Information System (INIS)

    Pivin, J.C.

    1989-01-01

    The mechanical behaviour of implantation films must be analysed in terms of bilayer rheology (laws of mechanical behaviour). Tribology takes into account thermodynamical, chemical and metallurgical parameters to interpret the friction properties of a system as a whole. One can distinguish between alloying effects of ion implantation and structural modifications. Alloying affects the basic properties of the crystal: elasticity, cohesion, mobility of planar defects, and its surface electronic structure, which determines the reactivity with the atmosphere or the friction counterpart (adhesion). Radiation damage and phase changes act more particularly on the modes of gliding and climbing of dislocations, and fracture mechanisms. 105 refs.; 11 figs.; 1 table

  17. [Tinnitus and implants].

    Science.gov (United States)

    Despreaux, G; Tison, P; Van Den Abbeele, T; Moine, A; Frachet, B

    1990-01-01

    The experience with cochlear implantation at Avicenne hospital prompted us to carry out a retrospective study on tinnitus in a population of operated patients. Improvement or disappearance of the symptoms was noted in all cases. These results, which partly match those found in the literature, are probably produced by rehabilitation inhibiting the "deafferentation" mechanisms in analogy with pain phenomena. In some precise cases, which are described, they led us to proposing implantation even though the main, if not sole, complaint of the patient was tinnitus.

  18. Surgical pitfalls with custom-made porous hydroxyapatite cranial implants

    Directory of Open Access Journals (Sweden)

    Bruno Zanotti

    2015-03-01

    Full Text Available Aim: Cranioplasty implants are used primarily in cases of surgical cranial decompression following pathological elevations of intracranial pressure. Available bone substitutes include porous hydroxyapatite (HA and polymethylmethacrylate. Whichever material is used, however, prosthetic cranial implants are susceptible to intra- and postsurgical complications and even failure. The aim of this study was to investigate such occurrences in HA cranioplasty implants, seeking not only to determine the likely causes (whether correlated or not with the device itself but also, where possible, to suggest countermeasures. Methods: We analyzed information regarding failures or complications reported in postmarketing surveillance and clinical studies of patients treated worldwide with custom-made HA cranial implants (Custom Bone Service Fin-Ceramica Faenza, Italy in the period 1997-2013. Results: The two most common complications were implant fractures (84 cases, 2.9% of the total fitted and infections (51 cases, 1.77%. Conclusion: Although cranioplasties are superficial and not difficult types of surgery, and use of custom-made implants are often considered the "easy" option from a surgical perspective, these procedures are nonetheless plagued by potential pitfalls. If performed well they yield more than satisfactory results from the points of view of both the patient and surgeon, but lack of appropriate care can open the door to numerous potential sources of failure, which can compromise-even irreparably-the ability to heal.

  19. The oxidation behaviour of lanthanum implanted stainless steels

    International Nuclear Information System (INIS)

    Ager, F.J.; Respaldiza, M.A.; Luna, C.; Botella, J.; Soares, C.G.; da Silva, M.F.

    1997-01-01

    Rare earth oxide deposition onto stainless steel surfaces has been attempted as a way of improving corrosion resistance at elevated temperatures. The improvement in the corrosion behaviour has been related to the modification of the diffusion mechanisms through the chromia protective layer. In a previous work we have postulated the formation of a LaCrO 3 as responsible for such a behaviour. Among the alternatives to deposit reactive elements, ion implantation has been chosen as a way of obtaining surface and/or subsurface alloys with the desired composition. During ion implantation, a modification of the alloy structure may also occur, resulting in a way of testing the influence of the alloy structure on the oxidation behaviour. In the present work we propose two procedures for obtaining the refractory behaviour implantation in the bulk alloy and in controlled preoxidized layers. Ion fluency has been chosen in such a way that final rare earth element concentration falls within the limits experimentally observed as adequate using wet chemistry methods. Excellent parabolic oxidation is observed in every case showing the efficiency of the implantation method both in the implanted bulk alloy as well as in the preoxidized specimens. The differences in the oxidation kinetics are related to the surface composition and to the structure of the implanted materials. (author)

  20. A phone-assistive device based on Bluetooth technology for cochlear implant users.

    Science.gov (United States)

    Qian, Haifeng; Loizou, Philipos C; Dorman, Michael F

    2003-09-01

    Hearing-impaired people, and particularly hearing-aid and cochlear-implant users, often have difficulty communicating over the telephone. The intelligibility of telephone speech is considerably lower than the intelligibility of face-to-face speech. This is partly because of lack of visual cues, limited telephone bandwidth, and background noise. In addition, cellphones may cause interference with the hearing aid or cochlear implant. To address these problems that hearing-impaired people experience with telephones, this paper proposes a wireless phone adapter that can be used to route the audio signal directly to the hearing aid or cochlear implant processor. This adapter is based on Bluetooth technology. The favorable features of this new wireless technology make the adapter superior to traditional assistive listening devices. A hardware prototype was built and software programs were written to implement the headset profile in the Bluetooth specification. Three cochlear implant users were tested with the proposed phone-adapter and reported good speech quality.

  1. The relationship of silicone breast implants and cancer at other sites.

    Science.gov (United States)

    Brinton, Louise A

    2007-12-01

    Although most attention regarding the effects of silicone breast implants on cancer risk has focused on breast cancer, there have also been concerns regarding effects on other cancers. This includes malignancies that could occur as a result of foreign-body carcinogenesis (sarcomas) or immune alterations (hematopoietic malignancies), or cancers suggested as possibly elevated on the basis of previous epidemiologic studies (cancers of the cervix, vulva, lung, and brain). Searches of the English language literature on the topic of silicone breast implants and cancer risk were conducted and reviewed to determine relationships that might have etiologic relevance. Epidemiologic studies provide no support for an increased risk of either sarcoma or multiple myeloma among breast implant recipients, disputing clinical and laboratory findings suggesting such a link. Although a number of epidemiologic studies have demonstrated elevated risks of cervical, vulvar, and lung cancers among breast implant patients, it is likely that these excesses relate more to lifestyle characteristics (e.g., cigarette smoking, sexual behavior) than to the effects of the implants. Brain cancer excesses, suggested in one study, have not been confirmed in either an update of the mortality experience in this study or on the basis of other investigations. At present, there is no convincing evidence that breast implants alter the risk of nonbreast malignancies. Breast implant patients should continue to be monitored for longer term risks and to assess whether cancer risk is influenced by various patient and implant characteristics.

  2. Outcomes of Late Implantation in Usher Syndrome Patients.

    Science.gov (United States)

    Hoshino, Ana Cristina H; Echegoyen, Agustina; Goffi-Gomez, Maria Valéria Schmidt; Tsuji, Robinson Koji; Bento, Ricardo Ferreira

    2017-04-01

    Introduction  Usher syndrome (US) is an autosomal recessive disorder characterized by hearing loss and progressive visual impairment. Some deaf Usher syndrome patients learn to communicate using sign language. During adolescence, as they start losing vision, they are usually referred to cochlear implantation as a salvage for their new condition. Is a late implantation beneficial to these children? Objective  The objective of this study is to describe the outcomes of US patients who received cochlear implants at a later age. Methods  This is a retrospective study of ten patients diagnosed with US1. We collected pure-tone thresholds and speech perception tests from pre and one-year post implant. Results  Average age at implantation was 18.9 years (5-49). Aided average thresholds were 103 dB HL and 35 dB HL pre and one-year post implant, respectively. Speech perception was only possible to be measured in four patients preoperatively, who scored 13.3; 26.67; 46% vowels and 56% 4-choice. All patients except one had some kind of communication. Two were bilingual. After one year of using the device, seven patients were able to perform the speech tests (from four-choice to close set sentences) and three patients abandoned the use of the implant. Conclusion  We observed that detection of sounds can be achieved with late implantation, but speech recognition is only possible in patients with previous hearing stimulation, since it depends on the development of hearing skills and the maturation of the auditory pathways.

  3. An elevator wheel

    Energy Technology Data Exchange (ETDEWEB)

    Zhornik, V.I.; Cherkov, Ye.M.; Simonov, A.A.

    1982-01-01

    This invention deals with mineral enrichment and is primarily for unloading submerged products of enrichment during separation in heavy mediums. An elevator wheel is proposed for unloading the submerged product from the bath of a heavy to medium separator which includes ladle disks with internal walls and overlapping sheets hinged to the ends. In order to increase the degree of dehydration of the unloaded product, the internal wall of each ladle is made of sheets installed in stages with clearances relative to each other. The advantages of the proposed device include an improvement in the degree of dehydration of the submerged product in the ladles and a reduction in the carry away of the heavy medium with the enrichment products.

  4. Identifying cochlear implant channels with poor electrode-neuron interface: electrically-evoked auditory brainstem responses measured with the partial tripolar configuration

    Science.gov (United States)

    Bierer, Julie Arenberg; Faulkner, Kathleen F.; Tremblay, Kelly L.

    2011-01-01

    Objectives The goal of this study was to compare cochlear implant behavioral measures and electrically-evoked auditory brainstem responses (EABRs) obtained with a spatially focused electrode configuration. It has been shown previously that channels with high thresholds, when measured with the tripolar configuration, exhibit relatively broad psychophysical tuning curves (Bierer and Faulkner, 2010). The elevated threshold and degraded spatial/spectral selectivity of such channels are consistent with a poor electrode-neuron interface, such as suboptimal electrode placement or reduced nerve survival. However, the psychophysical methods required to obtain these data are time intensive and may not be practical during a clinical mapping procedure, especially for young children. Here we have extended the previous investigation to determine if a physiological approach could provide a similar assessment of channel functionality. We hypothesized that, in accordance with the perceptual measures, higher EABR thresholds would correlate with steeper EABR amplitude growth functions, reflecting a degraded electrode-neuron interface. Design Data were collected from six cochlear implant listeners implanted with the HiRes 90k cochlear implant (Advanced Bionics). Single-channel thresholds and most comfortable listening levels were obtained for stimuli that varied in presumed electrical field size by using the partial tripolar configuration, for which a fraction of current (σ) from a center active electrode returns through two neighboring electrodes and the remainder through a distant indifferent electrode. EABRs were obtained in each subject for the two channels having the highest and lowest tripolar (σ=1 or 0.9) behavioral threshold. Evoked potentials were measured with both the monopolar (σ=0) and a more focused partial tripolar (σ ≥ 0.50) configuration. Results Consistent with previous studies, EABR thresholds were highly and positively correlated with behavioral thresholds

  5. Identifying cochlear implant channels with poor electrode-neuron interfaces: electrically evoked auditory brain stem responses measured with the partial tripolar configuration.

    Science.gov (United States)

    Bierer, Julie Arenberg; Faulkner, Kathleen F; Tremblay, Kelly L

    2011-01-01

    The goal of this study was to compare cochlear implant behavioral measures and electrically evoked auditory brain stem responses (EABRs) obtained with a spatially focused electrode configuration. It has been shown previously that channels with high thresholds, when measured with the tripolar configuration, exhibit relatively broad psychophysical tuning curves. The elevated threshold and degraded spatial/spectral selectivity of such channels are consistent with a poor electrode-neuron interface, defined as suboptimal electrode placement or reduced nerve survival. However, the psychophysical methods required to obtain these data are time intensive and may not be practical during a clinical mapping session, especially for young children. Here, we have extended the previous investigation to determine whether a physiological approach could provide a similar assessment of channel functionality. We hypothesized that, in accordance with the perceptual measures, higher EABR thresholds would correlate with steeper EABR amplitude growth functions, reflecting a degraded electrode-neuron interface. Data were collected from six cochlear implant listeners implanted with the HiRes 90k cochlear implant (Advanced Bionics). Single-channel thresholds and most comfortable listening levels were obtained for stimuli that varied in presumed electrical field size by using the partial tripolar configuration, for which a fraction of current (σ) from a center active electrode returns through two neighboring electrodes and the remainder through a distant indifferent electrode. EABRs were obtained in each subject for the two channels having the highest and lowest tripolar (σ = 1 or 0.9) behavioral threshold. Evoked potentials were measured with both the monopolar (σ = 0) and a more focused partial tripolar (σ ≥ 0.50) configuration. Consistent with previous studies, EABR thresholds were highly and positively correlated with behavioral thresholds obtained with both the monopolar and partial

  6. Recent advances in dental implants.

    Science.gov (United States)

    Hong, Do Gia Khang; Oh, Ji-Hyeon

    2017-12-01

    Dental implants are a common treatment for the loss of teeth. This paper summarizes current knowledge on implant surfaces, immediate loading versus conventional loading, short implants, sinus lifting, and custom implants using three-dimensional printing. Most of the implant surface modifications showed good osseointegration results. Regarding biomolecular coatings, which have been recently developed and studied, good results were observed in animal experiments. Immediate loading had similar clinical outcomes compared to conventional loading and can be used as a successful treatment because it has the advantage of reducing treatment times and providing early function and aesthetics. Short implants showed similar clinical outcomes compared to standard implants. A variety of sinus augmentation techniques, grafting materials, and alternative techniques, such as tilted implants, zygomatic implants, and short implants, can be used. With the development of new technologies in three-dimension and computer-aided design/computer-aided manufacturing (CAD/CAM) customized implants can be used as an alternative to conventional implant designs. However, there are limitations due to the lack of long-term studies or clinical studies. A long-term clinical trial and a more predictive study are needed.

  7. Untreated silicone breast implant rupture

    DEFF Research Database (Denmark)

    Hölmich, Lisbet R; Vejborg, Ilse M; Conrad, Carsten

    2004-01-01

    Implant rupture is a well-known complication of breast implant surgery that can pass unnoticed by both patient and physician. To date, no prospective study has addressed the possible health implications of silicone breast implant rupture. The aim of the present study was to evaluate whether untre...

  8. Biocompatibility of titanium based implants treated with plasma immersion ion implantation

    International Nuclear Information System (INIS)

    Maendl, S.; Sader, R.; Thorwarth, G.; Krause, D.; Zeilhofer, H.-F.; Horch, H.H.; Rauschenbach, B.

    2003-01-01

    In this work, the biocompatibility of titanium before and after oxygen PIII is investigated using a rat animal model. Pure titanium (grade 2) and pre-anodized titanium were implanted with oxygen at elevated temperatures between 200 and 550 deg. C and subsequently analyzed for oxygen content and phase composition. No deterioration of the tensile strength and the yield strength was detected after the implantation. The mechanical stability of the osseointegration was determined with a pull-out test, where an increased shear strength was measured after PIII treatment. Only a slight improvement of the bone contact area, from an already excellent starting value, was observed for pure titanium. In contrast, a significant improvement was found for anodized titanium after PIII treatment. This astonishing difference can be explained with the surface topography and the phase composition of the anodized titanium samples

  9. A hot implantation study on the evolution of defects in He ion implanted MgO(1 0 0)

    International Nuclear Information System (INIS)

    Fedorov, A.V.; Huis, M.A. van; Veen, A. van

    2002-01-01

    Ion implantation at elevated temperature, so-called hot implantation, was used to study nucleation and thermal stability of the defects. In this work, MgO(1 0 0) single crystal samples were implanted with 30 keV He ions at various implantation temperatures. The implantation doses ranged from 10 14 to 10 16 cm -2 . The implantation introduced defects were subsequently studied by thermal helium desorption spectroscopy (THDS) and Doppler broadening positron beam analysis (PBA). The THDS study provides vital information on the kinetics of He release from the sample. PBA technique, being sensitive to the open volume defects, provides complementary information on cavity evolution. The THD study has shown that in most cases helium release is characterised by the activation energy of Q=4.7±0.5 eV with the maximum release temperature of T max =1830 K. By applying first order desorption model the pre-exponent factor is estimated as ν=4.3x10 11 s -1

  10. Quantifying risk of penile prosthesis infection with elevated glycosylated hemoglobin.

    Science.gov (United States)

    Wilson, S K; Carson, C C; Cleves, M A; Delk, J R

    1998-05-01

    Elevation of glycosylated hemoglobin above levels of 11.5 mg.% has been considered a contraindication to penile prosthesis implantation in diabetic patients. We determine the predictive value of glycosylated hemoglobin A1C in penile prosthesis infections in diabetic and nondiabetic patients to confirm or deny this prevalent opinion. We conducted a 2-year prospective study of 389 patients, including 114 diabetics, who underwent 3-piece penile prosthesis implantation. All patients had similar preoperative preparation without regard to diabetic status, control or glycosylated hemoglobin A1C level. Risk of infection was statistically analyzed for diabetics versus nondiabetics, glycosylated hemoglobin A1C values above and below 11.5 mg.%, insulin dependent versus oral medication diabetics, and fasting blood sugars above and below 180 mg.%. Prosthesis infections developed in 10 diabetics (8.7%) and 11 nondiabetics (4.0%). No increased infection rate was observed in diabetics with high fasting sugars or diabetics on insulin. There was no statistically significant increased infection risk with increased levels of glycosylated hemoglobin A1C among all patients or among only the diabetics. In fact, there was no meaningful difference in the median or mean level of glycosylated hemoglobin A1C in the infected and noninfected patients regardless of diabetes. Use of glycosylated hemoglobin A1C values to identify and exclude surgical candidates with increased risk of infections is not proved by this study. Elevation of fasting sugar or insulin dependence also does not increase risk of infection in diabetics undergoing prosthesis implantation.

  11. Semiconductor Ion Implanters

    International Nuclear Information System (INIS)

    MacKinnon, Barry A.; Ruffell, John P.

    2011-01-01

    In 1953 the Raytheon CK722 transistor was priced at $7.60. Based upon this, an Intel Xeon Quad Core processor containing 820,000,000 transistors should list at $6.2 billion! Particle accelerator technology plays an important part in the remarkable story of why that Intel product can be purchased today for a few hundred dollars. Most people of the mid twentieth century would be astonished at the ubiquity of semiconductors in the products we now buy and use every day. Though relatively expensive in the nineteen fifties they now exist in a wide range of items from high-end multicore microprocessors like the Intel product to disposable items containing 'only' hundreds or thousands like RFID chips and talking greeting cards. This historical development has been fueled by continuous advancement of the several individual technologies involved in the production of semiconductor devices including Ion Implantation and the charged particle beamlines at the heart of implant machines. In the course of its 40 year development, the worldwide implanter industry has reached annual sales levels around $2B, installed thousands of dedicated machines and directly employs thousands of workers. It represents in all these measures, as much and possibly more than any other industrial application of particle accelerator technology. This presentation discusses the history of implanter development. It touches on some of the people involved and on some of the developmental changes and challenges imposed as the requirements of the semiconductor industry evolved.

  12. Implantable enzyme amperometric biosensors.

    Science.gov (United States)

    Kotanen, Christian N; Moussy, Francis Gabriel; Carrara, Sandro; Guiseppi-Elie, Anthony

    2012-05-15

    The implantable enzyme amperometric biosensor continues as the dominant in vivo format for the detection, monitoring and reporting of biochemical analytes related to a wide range of pathologies. Widely used in animal studies, there is increasing emphasis on their use in diabetes care and management, the management of trauma-associated hemorrhage and in critical care monitoring by intensivists in the ICU. These frontier opportunities demand continuous indwelling performance for up to several years, well in excess of the currently approved seven days. This review outlines the many challenges to successful deployment of chronically implantable amperometric enzyme biosensors and emphasizes the emerging technological approaches in their continued development. The foreign body response plays a prominent role in implantable biotransducer failure. Topics considering the approaches to mitigate the inflammatory response, use of biomimetic chemistries, nanostructured topographies, drug eluting constructs, and tissue-to-device interface modulus matching are reviewed. Similarly, factors that influence biotransducer performance such as enzyme stability, substrate interference, mediator selection and calibration are reviewed. For the biosensor system, the opportunities and challenges of integration, guided by footprint requirements, the limitations of mixed signal electronics, and power requirements, has produced three systems approaches. The potential is great. However, integration along the multiple length scales needed to address fundamental issues and integration across the diverse disciplines needed to achieve success of these highly integrated systems, continues to be a challenge in the development and deployment of implantable amperometric enzyme biosensor systems. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. HA-Coated Implant

    DEFF Research Database (Denmark)

    Daugaard, Henrik; Søballe, Kjeld; Bechtold, Joan E

    2014-01-01

    of improving the fixation of implants. Of these, hydroxyapatite (HA) is the most widely used and most extensively investigated. HA is highly osseoconductive, and the positive effect is well documented in both basic and long-term clinical research [1–6]. This chapter describes experimental and clinical studies...

  14. Middle ear implants

    Directory of Open Access Journals (Sweden)

    K S Gangadhara Somayaji

    2013-01-01

    Full Text Available Hearing loss is becoming more common in the society living in cities with lot of background noise around, and frequent use of gadgets like mobile phones, MP3s, and IPods are adding to the problem. The loss may involve the conductive or perceptive pathway. Majority of the patients with conductive hearing loss will revert back to normal hearing levels with medical and/or surgical treatment. However, in sensorineural hearing loss, many factors are involved in the management. Though traditionally hearing aids in various forms are the most commonly used modality in managing these patients, there are some drawbacks associated with them. Implantable middle ear amplifiers represent the most recent breakthrough in the management of hearing loss. Middle ear implants are surgically implanted electronic devices that aim to correct hearing loss by stimulating the ossicular chain or middle ear. Of late, they are also being used in the management of congenital conductive hearing loss and certain cases of chronic otitis media with residual hearing loss. The article aims to provide general information about the technology, indications and contraindications, selection of candidates, available systems, and advantages of middle ear implants. (MEI

  15. Delayed breast implant reconstruction

    DEFF Research Database (Denmark)

    Hvilsom, Gitte B.; Hölmich, Lisbet R.; Steding-Jessen, Marianne

    2011-01-01

    the period 1999 to 2006; 239 one-stage procedures and 353 two-stage procedures. The postoperative course through November 2009 was evaluated by cumulative incidence adjusting for competing risks for the selected outcomes; hematoma, infection, seroma, implant rupture, severe capsular contracture (modified...

  16. Remote actuated valve implant

    Science.gov (United States)

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  17. Hermetic electronic packaging of an implantable brain-machine-interface with transcutaneous optical data communication.

    Science.gov (United States)

    Schuettler, Martin; Kohler, Fabian; Ordonez, Juan S; Stieglitz, Thomas

    2012-01-01

    Future brain-computer-interfaces (BCIs) for severely impaired patients are implanted to electrically contact the brain tissue. Avoiding percutaneous cables requires amplifier and telemetry electronics to be implanted too. We developed a hermetic package that protects the electronic circuitry of a BCI from body moisture while permitting infrared communication through the package wall made from alumina ceramic. The ceramic package is casted in medical grade silicone adhesive, for which we identified MED2-4013 as a promising candidate.

  18. Assessment of a polyelectrolyte multilayer film coating loaded with BMP-2 on titanium and PEEK implants in the rabbit femoral condyle

    Science.gov (United States)

    Guillot, R.; Pignot-Paintrand, I.; Lavaud, J.; Decambron, A.; Bourgeois, E.; Josserand, V.; Logeart-Avramoglou, D.; Viguier, E.; Picart, C.

    2016-01-01

    The aim of this study was to evaluate the osseointegration of titanium implants (Ti-6Al-4V, noted here TA6V) and poly(etheretherketone) PEEK implants induced by a BMP-2-delivering surface coating made of polyelectrolyte multilayer films. The in vitro bioactivity of the polyelectrolyte film-coated implants was assessed using the alkaline phosphatase assay. BMP-2-coated TA6V and PEEK implants with a total dose of 9.3 µg of BMP-2 were inserted into the femoral condyles of New Zealand white rabbits and compared to uncoated implants. Rabbits were sacrificed 4 and 8 weeks after implantation. Histomorphometric analyses on TA6V and PEEK implants and microcomputed tomography on PEEK implants revealed that the bone-to-implant contact and bone area around the implants were significantly lower for the BMP-2-coated implants than for the bare implants. This was confirmed by scanning electron microscopy imaging. This difference was more pronounced at 4 weeks in comparison to the 8-week time point. However, bone growth inside the hexagonal upper hollow cavity of the screws was higher in the case of the BMP-2 coated implants. Overall, this study shows that a high dose of BMP-2 leads to localized and temporary bone impairment, and that the dose of BMP-2 delivered at the surface of an implant needs to be carefully optimized. PMID:26965394

  19. Thin type inverter for machine-room-less elevator; Machine roomless elevator yo usugata inverter

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-01-10

    In the elevator industry, a machine-room-less elevator, which does not necessitate a machine room usually installed on the roof, has come into the spotlight in the domain of low and intermediate speed elevators. The lack of a machine room, however, will necessarily limit the space for the installation of the traction motor and control panel. Fuji Electric Co., Ltd., in order to properly cope with the situation, has developed in cooperation with Fujitec Co., Ltd., a very thin type inverter installable on an elevator hall floor. The inverter, based on Fuji Electric's high-performance vector control inverter FRENIC5000VG5, is as thin as 100mm, and is available in three series up to 11kW. For the embodiment of such a thin structure, a cooling structure of Fuji Electric's own is employed, and prudence is exercised as required at many locations so that maintainability will not be impaired throughout the very thin control panel design. (translated by NEDO)

  20. Two-stage implant placement technique for the management of irradiated jaws: An animal study.

    Science.gov (United States)

    Aboushelib, Moustafa N; Arnaout, Mohamed A; Elsafi, Mohamed H; Kassem, Youssef M

    2017-10-01

    Radiotherapy results in diminished bone remodeling capacity and an elevated risk of osteoradionecrosis, which can negatively influence the survival rate of dental implants. Patients receiving radiotherapy are advised not to receive dental implants during or soon after completing their radiotherapy. The purpose of this animal study was to investigate a 2-stage implant placement technique designed to diminish applied trauma on irradiated bone. Two groups of white New Zealand rabbits received radiotherapy in ascending doses (2, 4, 8 Gy), while a nonirradiated group served as control. Three weeks after completion of the last radiotherapy session, one of the irradiated groups and the control group received titanium dental implants bilaterally in the femur head. For the second irradiated group, an osteotomy was performed, and the surgical wound was left to heal for 2 weeks before implant placement. All animals were sacrificed 4 weeks after implant placement, and histomorphometric analysis was used to study bone-implant contact (n=14, α=.05). Statistical analysis revealed significantly higher (F=159, P<.001) bone-implant contact in the 2-stage (40.2 ±1.9) implant placement technique than in the immediately placed implants (21.2 ±2.3) in irradiated bone. Both of the groups had a significantly lower bone-to-implant contact ratio than the non-irradiated control (64.2 ±3.8). Within the limitations of this animal study, the 2-stage implant placement technique could be used to reduce trauma in irradiated bone and to improve wound healing around dental implants. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  1. Cochlear Implants (For Parents)

    Science.gov (United States)

    ... What Happens in the Operating Room? Can Loud Music Hurt My Ears? Your Ears Word! Cochlea Hearing Impairment Hearing Aids Earbuds Ears View more About Us Contact Us Partners Editorial Policy Permissions Guidelines Privacy Policy & Terms of Use Notice ...

  2. Periconception onset diabetes is associated with embryopathy and fetal growth retardation, reproductive tract hyperglycosylation and impaired immune adaptation to pregnancy.

    Science.gov (United States)

    Brown, Hannah M; Green, Ella S; Tan, Tiffany C Y; Gonzalez, Macarena B; Rumbold, Alice R; Hull, M Louise; Norman, Robert J; Packer, Nicolle H; Robertson, Sarah A; Thompson, Jeremy G

    2018-02-01

    Diabetes has been linked with impaired fertility but the underlying mechanisms are not well defined. Here we use a streptozotocin-induced diabetes mouse model to investigate the cellular and biochemical changes in conceptus and maternal tissues that accompany hyperglycaemia. We report that streptozotocin treatment before conception induces profound intra-cellular protein β-O-glycosylation (O-GlcNAc) in the oviduct and uterine epithelium, prominent in early pregnancy. Diabetic mice have impaired blastocyst development and reduced embryo implantation rates, and delayed mid-gestation growth and development. Peri-conception changes are accompanied by increased expression of pro-inflammatory cytokine Trail, and a trend towards increased Il1a, Tnf and Ifng in the uterus, and changes in local T-cell dynamics that skew the adaptive immune response to pregnancy, resulting in 60% fewer anti-inflammatory regulatory T-cells within the uterus-draining lymph nodes. Activation of the heat shock chaperones, a mechanism for stress deflection, was evident in the reproductive tract. Additionally, we show that the embryo exhibits elevated hyper-O-GlcNAcylation of both cytoplasmic and nuclear proteins, associated with activation of DNA damage (ɣH2AX) pathways. These results advance understanding of the impact of peri-conception diabetes, and provide a foundation for designing interventions to support healthy conception without propagation of disease legacy to offspring.

  3. Implant-assisted removable partial dentures: practical considerations.

    Science.gov (United States)

    Omura, Aaron J; Latthe, Vaibhav; Marin, Mark M; Cagna, David R

    2016-01-01

    At the heart of prosthodontic treatment planning must be a sound understanding of the quality and reliability of the prosthodontic foundation. Implant prosthodontics relies almost entirely on the biological and mechanical properties of an osseous foundation. Initiation of therapy in the absence of a healthy and stable prosthodontic foundation risks unintended and suboptimal treatment outcomes. For conventional removable partial denture (RPD) therapy, consideration must be given to interactions between the soft and hard tissues available to support and stabilize planned prostheses. The strategic addition of implants to the partially edentulous foundation can improve the support, comfort, and esthetics of an RPD, resulting in elevated patient satisfaction and greater therapeutic success. This article discusses aspects of diagnosis, treatment planning, clinical management, laboratory execution, and maintenance that must be considered in order to obtain optimal results with implant-assisted RPDs.

  4. Defect-impurity interactions in ion-implanted metals

    International Nuclear Information System (INIS)

    Turos, A.

    1986-01-01

    An overview of defect-impurity interactions in metals is presented. When point defects become mobile they migrate towards the sinks and on the way can be captured by impurity atoms forming stable associations so-called complexes. In some metallic systems complexes can also be formed athermally during ion implantation by trapping point defects already in the collision cascade. An association of a point defect with an impurity atom leads to its displacement from the lattice site. The structure and stability of complexes are strongly temperature dependent. With increasing temperature they dissociate or grow by multiple defect trapping. The appearance of freely migrating point defects at elevated temperatures, due to ion bombardment or thermal annealing, causes via coupling with defect fluxes, important impurity redistribution. Because of the sensitivity of many metal-in-metal implanted systems to radiation damage the understanding of this processes is essential for a proper interpretation of the lattice occupancy measurements and the optimization of implantation conditions. (author)

  5. High-temperature superconductors induced by ion implantation. Final report

    International Nuclear Information System (INIS)

    Greenwald, A.C.; Johnson, E.

    1988-08-01

    High dose oxygen ion implantation (10 to the 17th power ions per sq. cm.) at elevated temperatures (300 C) has been shown to adjust the critical temperature of gamma-Y-Ba-Cu-O and Bi-Ca-Sr-Cu-O materials. These results are in marked contrast to earlier work which showed complete destruction of superconducting properties for similar radiation doses, and marked reduction in superconducting properties at one-tenth this dose in the 1-2-3- compound only. Experiments also showed that the superconducting materials can be patterned into conducting and nonconducting areas without etching by ion implantation, allowing maintenance of planar geometries required for microcircuit fabrication. Experiments on deposition of thin films of high temperature superconductors for use with the ion implantation experiments showed that ion beam sputtering from a single target could achieve the correct stoichiometry. Variations of composition with ion beam energy and angle of sputtered ions were studied

  6. Lattice damage in ion-implanted silicon-germanium alloys

    International Nuclear Information System (INIS)

    Haynes, T.E.; Holland, O.W.

    1992-08-01

    The damage produced in Si 1-x Ge x alloys (0≤x≤1) by implantation of 70--100 keV 30 Si + has been measured as a function of temperature and fluence by ion channeling. For all compositions, the damage efficiency decreased sharply as the implant temperature was increased between room temperature and 150 degrees C. Furthermore, the damage efficiency in alloys of intermediate compositions (0.34≤x≤0.5) exceeds that in Ge, especially at elevated temperatures, despite the larger cascade energy density in Ge. It is shown that this behavior can be described based on a model in which the point-defect mobility is the dominant factor controlling damage retention, rather than the cascade energy density. This approach provides a framework for understanding other temperature-dependent phenomena related to damage growth in Si-Ge alloys including dose-rate effects and damage saturation in MeV implantation

  7. Oral Rehabilitation with Implant-Retained Overdenture in a Patient with Down Syndrome.

    Science.gov (United States)

    Altintas, Nuray Yilmaz; Kilic, Serdar; Altintas, Subutay Han

    2017-01-24

    Down syndrome, known as trisomy 21, is the most common chromosomal disorder. The disorder affects mental and systemic development as well as oral structure, including dental anomalies, high susceptibility of periodontal disease, and poor quality of alveolar bone. This report presents a case of dental rehabilitation by means of dental implants of a patient with Down syndrome. Two titanium dental implants were placed in the maxilla, and three titanium dental implants were installed in the mandible. One implant was lost during the osseointegration period. The prosthetic rehabilitation was performed with implant-retained maxillary and mandibular overdentures with the Locator attachment system. After a 2-year follow-up period, the patient was doing well, and all implants were clinically stable with no signs of bone loss or inflammation. The present study emphasizes that implant-retained overdentures with Locator attachment system could be a therapeutic option even for patients with Down syndrome. This therapy prevents crestal bone loss around the implants, improves functional and esthetic outcomes, and provides optimum oral hygiene for patients with mild mental impairment. Careful patient selection and education of patients and caregivers are essential considerations for a successful and safe treatment with dental implants in Down syndrome patients. © 2017 by the American College of Prosthodontists.

  8. Outcomes of cochlear implantation in deaf children of deaf parents: comparative study.

    Science.gov (United States)

    Hassanzadeh, S

    2012-10-01

    This retrospective study compared the cochlear implantation outcomes of first- and second-generation deaf children. The study group consisted of seven deaf, cochlear-implanted children with deaf parents. An equal number of deaf children with normal-hearing parents were selected by matched sampling as a reference group. Participants were matched based on onset and severity of deafness, duration of deafness, age at cochlear implantation, duration of cochlear implantation, gender, and cochlear implant model. We used the Persian Auditory Perception Test for the Hearing Impaired, the Speech Intelligibility Rating scale, and the Sentence Imitation Test, in order to measure participants' speech perception, speech production and language development, respectively. Both groups of children showed auditory and speech development. However, the second-generation deaf children (i.e. deaf children of deaf parents) exceeded the cochlear implantation performance of the deaf children with hearing parents. This study confirms that second-generation deaf children exceed deaf children of hearing parents in terms of cochlear implantation performance. Encouraging deaf children to communicate in sign language from a very early age, before cochlear implantation, appears to improve their ability to learn spoken language after cochlear implantation.

  9. Beam Profile Disturbances from Implantable Pacemakers or Implantable Cardioverter-Defibrillator Interactions

    Energy Technology Data Exchange (ETDEWEB)

    Gossman, Michael S., E-mail: mgossman@tsrcc.com [Tri-State Regional Cancer Center, Medical Physics Section, Ashland, KY (United States); Comprehensive Heart and Vascular Associates, Heart and Vascular Center, Ashland, KY (United States); Medtronic, Inc., External Research Program, Mounds View, MN (United States); Nagra, Bipinpreet; Graves-Calhoun, Alison; Wilkinson, Jeffrey [Tri-State Regional Cancer Center, Medical Physics Section, Ashland, KY (United States); Comprehensive Heart and Vascular Associates, Heart and Vascular Center, Ashland, KY (United States); Medtronic, Inc., External Research Program, Mounds View, MN (United States)

    2011-01-01

    The medical community is advocating for progressive improvement in the design of implantable cardioverter-defibrillators and implantable pacemakers to accommodate elevations in dose limitation criteria. With advancement already made for magnetic resonance imaging compatibility in some, a greater need is present to inform the radiation oncologist and medical physicist regarding treatment planning beam profile changes when such devices are in the field of a therapeutic radiation beam. Treatment plan modeling was conducted to simulate effects induced by Medtronic, Inc.-manufactured devices on therapeutic radiation beams. As a continuation of grant-supported research, we show that radial and transverse open beam profiles of a medical accelerator were altered when compared with profiles resulting when implantable pacemakers and cardioverter-defibrillators are placed directly in the beam. Results are markedly different between the 2 devices in the axial plane and the sagittal planes. Vast differences are also presented for the therapeutic beams at 6-MV and 18-MV x-ray energies. Maximum changes in percentage depth dose are observed for the implantable cardioverter-defibrillator as 9.3% at 6 MV and 10.1% at 18 MV, with worst distance to agreement of isodose lines at 2.3 cm and 1.3 cm, respectively. For the implantable pacemaker, the maximum changes in percentage depth dose were observed as 10.7% at 6 MV and 6.9% at 18 MV, with worst distance to agreement of isodose lines at 2.5 cm and 1.9 cm, respectively. No differences were discernible for the defibrillation leads and the pacing lead.

  10. Group control of elevators

    Energy Technology Data Exchange (ETDEWEB)

    Umeda, Yasukazu; Hikita, Shiro; Tuji, Sintaro (Mitsubishi Electric Corp., Tokyo (Japan))

    1988-09-05

    Items to be evaluated in the group control of elevators, and a typical control system are described. A new system in which the fuzzy rule base is employed is introduced together with the configuration. The items to be evaluated are waiting time, riding time, accuracy of forecasting, energy saving, and ease of usage. The everage waiting time of less than 20 seconds with less than 3% waiting rate of more than 60 seconds is accepted as a satisfactory service condition. There are many conflicting matters in group-controlling, and the study for the controlling must deal with the optimization of multi-purpose problems. The standards for group-control evaluation differ according to building structures and the tastes of users, and an important problem is where to give emphasis of the evaluation. The TRAFFIC PATTERN LEARNING METHOD has been applied in the system for careful control to accommodate the traffic. No specific function is provided for the evaluation, but the call allocation is made by fuzzy rule-base. The configuration of a new group-control system is introduced. 7 references, 7 figures, 1 table.

  11. Relaxation of mechanical stresses in Si-Ge/Si structures implanted by carbon ions. Study with optical methods

    International Nuclear Information System (INIS)

    Klyuj, M.Yi.

    1998-01-01

    Optical properties of Si-Ge/Si structures implanted by carbon ions with the energy of 20 keV and at the doses of 5 centre dot 10 15 - 1- 16 cm -2 are studied by spectro ellipsometry and Raman scattering techniques. From the comparison of experimental data with the results of theoretical calculations, it is shown that, as a result of implantation, a partial relaxation of mechanical stresses in the Si 1-x Ge x film due to introduction of carbon atoms with a small covalent radius into the Si-Ge lattice takes place. An elevated implantation temperature allows one to maintain a high structural perfection of the implanted film

  12. Productivity of lexical categories in French-speaking children with cochlear implants.

    Science.gov (United States)

    Le Normand, M-T; Ouellet, C; Cohen, H

    2003-11-01

    The productivity of lexical categories was studied longitudinally in a sample of 17 young hearing-impaired French-speaking children with cochlear implants. Age of implantation ranged from 22 months to 76 months. Spontaneous speech samples were collected at six-month intervals over a period of 36 months, starting at the one-word stage. Four general measures of their linguistic production (number of utterances, verbal fluency, vocabulary, and grammatical production) as well as 36 specific lexical categories, according to the CHILDES codes, were computed in terms of tokens, i.e., total number of words. Cochlear-implanted children (CI) were compared to a French database of normally hearing children aged 2-4 compiled by the first author. Follow-up results indicate that, at the two-year post-implantation follow-up, noun, and verb morphology was significantly impaired. At the three-year follow-up, the cochlear-implanted group had recovered on adjectives, determiners and nouns, main verbs, and auxiliaries. The two groups differed significantly in processing locative adverbs, prepositions, pronouns, and verbs (infinitive verb, modal, and modal lexical), but individual variability within the cochlear-implanted group was substantial. Results are discussed in terms of recovery and developmental trends and variability in the acquisition of lexical categories by French children two years and three years post-implantation.

  13. In situ Transmission Electron Microscopy He{sup +} implantation and thermal aging of nanocrystalline iron

    Energy Technology Data Exchange (ETDEWEB)

    Muntifering, Brittany, E-mail: brmunti@sandia.gov [Sandia National Laboratories, Albuquerque, NM, 87185 (United States); Department of Civil and Environmental Engineering, Northwestern University, Evanston, IL, 60208 (United States); Fang, Youwu [Department of Civil and Environmental Engineering, Northwestern University, Evanston, IL, 60208 (United States); Leff, Asher C. [Department of Materials Science & Engineering, Drexel University, Philadelphia, PA, 19104 (United States); Dunn, Aaron [Sandia National Laboratories, Albuquerque, NM, 87185 (United States); George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, UMI 2958 Georgia Tech CNRS, 57070, Metz (France); Qu, Jianmin [Department of Civil and Environmental Engineering, Northwestern University, Evanston, IL, 60208 (United States); School of Engineering, Tufts University, Medford, MA, 02155 (United States); Taheri, Mitra L. [Department of Materials Science & Engineering, Drexel University, Philadelphia, PA, 19104 (United States); Dingreville, Remi; Hattar, Khalid [Sandia National Laboratories, Albuquerque, NM, 87185 (United States)

    2016-12-15

    The high density of interfaces in nanostructured materials are hypothesized to improve radiation tolerance compared to coarse-grained materials. In order to investigate the roles of vacancies, self-interstitials, and helium, both room temperature in situ TEM He{sup +} implantation and annealing, as well as high temperature He{sup +} implantation was performed on nanocrystalline iron. Dislocation loops are formed by the accumulation of mobile point defects rather than by displacement cascades at intermediate temperatures. Around 600 °C, loops disappeared through gradual shrinking, which is hypothesized to correspond to the annihilation of self-interstitial atoms by mobile vacancies that also resulted in cavity formation. The room temperature implantation resulted in cavities evenly distributed throughout the grain after annealing, whereas cavities were predominately observed at grain boundaries for the elevated temperature implantation. This difference is associated with the formation of stable helium-vacancy complexes in the grains during room temperature implantation, which is not present during high temperature implantation. - Highlights: • In situ TEM He{sup +} implantation and annealing was performed on nanocrystalline iron. • Small grains limited loop size and resulted in complete disappearance of loops by 600 °C. • Implantation followed by annealing resulted in cavities evenly distributed through grain. • Cavities predominately observed at grain boundaries after He{sup +} implantation at 600 °C.

  14. Elevated arousal levels enhance contrast perception.

    Science.gov (United States)

    Kim, Dongho; Lokey, Savannah; Ling, Sam

    2017-02-01

    Our state of arousal fluctuates from moment to moment-fluctuations that can have profound impacts on behavior. Arousal has been proposed to play a powerful, widespread role in the brain, influencing processes as far ranging as perception, memory, learning, and decision making. Although arousal clearly plays a critical role in modulating behavior, the mechanisms underlying this modulation remain poorly understood. To address this knowledge gap, we examined the modulatory role of arousal on one of the cornerstones of visual perception: contrast perception. Using a reward-driven paradigm to manipulate arousal state, we discovered that elevated arousal state substantially enhances visual sensitivity, incurring a multiplicative modulation of contrast response. Contrast defines vision, determining whether objects appear visible or invisible to us, and these results indicate that one of the consequences of decreased arousal state is an impaired ability to visually process our environment.

  15. Lærer-elev-relationer

    DEFF Research Database (Denmark)

    Laursen, Per Fibæk; Nielsen, Anne Maj

    2015-01-01

    I kapitlet belyser vi relationskompetence i forholdet mellem lærer og elever og hvordan læreren kan arbejde med forhold til elever og med sin opmærksomhed på relationsarbejdet. Afslutningsvis ser vi på hvordan lærere fortsat kan udvikle deres relationskompetence.......I kapitlet belyser vi relationskompetence i forholdet mellem lærer og elever og hvordan læreren kan arbejde med forhold til elever og med sin opmærksomhed på relationsarbejdet. Afslutningsvis ser vi på hvordan lærere fortsat kan udvikle deres relationskompetence....

  16. Tanzania Elevation and Surface Characteristics

    Data.gov (United States)

    US Agency for International Development — The dataset displays Elevation, Slope, Aspect, Topographic Position Index, Terrain Ruggedness, and Roughness based on Shuttle Radar Topography Mission (SRTM) (3...

  17. Temperature evaluation of dental implant surface irradiated with high-power diode laser.

    Science.gov (United States)

    Rios, F G; Viana, E R; Ribeiro, G M; González, J C; Abelenda, A; Peruzzo, D C

    2016-09-01

    The prevalence of peri-implantitis and the absence of a standard approach for decontamination of the dental implant surface have led to searches for effective therapies. Since the source of diode lasers is portable, has reduced cost, and does not cause damage to the titanium surface of the implant, high-power diode lasers have been used for this purpose. The effect of laser irradiation on the implants is the elevation of the temperature surface. If this elevation exceeds 47 °C, the bone tissue is irreversibly damaged, so for a safety therapy, the laser parameters should be controlled. In this study, a diode laser of GaAsAl was used to irradiate titanium dental implants, for powers 1.32 to 2.64 W (real) or 2.00 to 4.00 W (nominal), in continuous/pulsed mode DC/AC, with exposure time of 5/10 s, with/without air flow for cooling. The elevation of the temperature was monitored in real time in two positions: cervical and apical. The best results for decontamination using a 968-nm diode laser were obtained for a power of 1.65 and 1.98 W (real) for 10 s, in DC or AC mode, with an air flow of 2.5 l/min. In our perspective in this article, we determine a suggested approach for decontamination of the dental implant surface using a 968-nm diode laser.

  18. Criteria for driver impairment

    NARCIS (Netherlands)

    Brookhuis, K.A.; De Waard, D.; Fairclough, S.H

    2003-01-01

    Most traffic accidents can be attributed to driver impairment, e.g. inattention, fatigue, intoxication, etc. It is now technically feasible to monitor and diagnose driver behaviour with respect to impairment with the aid of a limited number of in-vehicle sensors. However, a valid framework for the

  19. Efter cochlear implant

    DEFF Research Database (Denmark)

    Højen, Anders

    Dit barn har netop fået et cochlear implant. Hvad nu? Skal barnet fokusere udelukkende på at lære talt sprog, eller skal det også lære/fortsætte med tegnsprog eller støttetegn? Det er et vanskeligt spørgsmål, og før valget foretages, er det vigtigt at vurdere hvilke konsekvenser valget har, dels...... for den sproglige udvikling isoleret set, og dels for barnets udvikling ud fra en helhedsbetragtning. Dette indlæg fokuserer på, hvilke forventninger man kan have til cochlear implant-brugeres sproglige udvikling med talt sprog alene, hhv. med to sprog (tale og tegn). Disse forventninger er baseret på...

  20. Delayed breast implant reconstruction

    DEFF Research Database (Denmark)

    Hvilsom, Gitte B.; Hölmich, Lisbet R.; Steding-Jessen, Marianne

    2012-01-01

    We evaluated the association between radiation therapy and severe capsular contracture or reoperation after 717 delayed breast implant reconstruction procedures (288 1- and 429 2-stage procedures) identified in the prospective database of the Danish Registry for Plastic Surgery of the Breast during...... of radiation therapy was associated with a non-significantly increased risk of reoperation after both 1-stage (HR = 1.4; 95% CI: 0.7-2.5) and 2-stage (HR = 1.6; 95% CI: 0.9-3.1) procedures. Reconstruction failure was highest (13.2%) in the 2-stage procedures with a history of radiation therapy. Breast...... reconstruction approaches other than implants should be seriously considered among women who have received radiation therapy....

  1. Ion implantation in metals

    International Nuclear Information System (INIS)

    Vook, F.L.

    1977-02-01

    The application of ion beams to metals is rapidly emerging as a promising area of research and technology. This report briefly describes some of the recent advances in the modification and study of the basic properties of metals by ion implantation techniques. Most of the research discussed illustrates some of the new and exciting applications of ion beams to metals which are under active investigation at Sandia Laboratories, Albuquerque

  2. Use of bone compressors and atraumatic bone elevators in crestal sinus lift.

    Science.gov (United States)

    Di Alberti, L; Tamborrino, F; Di Vera, A; Lo Muzio, L; Rossetto, A; D'Agostino, A; De Santis, D; Bertossi, D

    2013-06-11

    Atrophy of the alveolar processes of the jaws, as a result of edentulism, often cannot allow a prosthetic rehabilitation, also if it only consists of a total removable prosthesis - for the inadequate base support - and also if it is backed by implants, because the small residual thickness bone compromises the primary implant stability, a fundamental requirement for a correct osseointegration. In addition to atrophy itself, the presence of noble structures (maxillary sinus, inferior alveolar nerve) make an implant-prosthetic rehabilitation contraindicated. To obviate this problem, there are many techniques to increase bone. The technique of the maxillary sinus elevation allows the increasing of the residual bone up to reach the minimum thickness in order to insert an implant. With this work we want to analyze the properties of the Bone Compression Kit (MIS, Israel) that make this surgical procedure safe, simple to perform, and predictable.

  3. The breast implant controversy.

    Science.gov (United States)

    Cook, R R; Harrison, M C; LeVier, R R

    1994-02-01

    The breast implant issue is a "bad news/good news" story. For many women with implants, the controversy has caused a fair degree of anxiety which may or may not be resolved as further information becomes available. It has also taken its toll on Dow Corning. Whole lines of medical products have been eliminated or are being phase out. The development of new medical applications has been terminated. As a consequence, employees have lost their jobs. What the effect will be on the biomedical industry as a whole remains to be seen (11). While silicones have been an important component in various medical devices, it is likely that other materials can be used as replacements. However, suppliers of non-silicone materials are also reevaluating their role in this market. For example, Du Pont, the nation's largest chemical company, has determined that the unpredictable and excessive costs of doing business with manufacturers of implantable medical devices no longer justifies the unrestricted sale of standard raw materials into this industry. Other companies are quietly following suit. On the up side, it is possible that the research being driven by this controversy will result in a greater understanding of the immunologic implications of xenobiotics, of the importance of nonbiased observations, of the need for ready access to valid data sets, and of the opportunity for valid scientific information to guide legal decisions. Only time will tell.

  4. Microstructure and tribology of carbon, nitrogen, and oxygen implanted ferrous materials

    International Nuclear Information System (INIS)

    Williamson, D.L.

    1993-01-01

    Nitrogen, carbon, and oxygen ions have been implanted into ferrous materials under unusual conditions of elevated temperatures and very high dose rates. The tribological durabilities of the resulting surfaces are examined with a special type of pin-on-disc wear test apparatus and found in most cases to be dramatically improved compared to surfaces prepared with conventional implantation conditions. Near-surface microstructures and compositions are characterized after implantation and after wear testing by backscatter Moessbauer spectroscopy, X-ray diffraction, scanning electron microscopy, and Auger electron spectroscopy. These data provide evidence for the predominant mechanisms responsible for the observed sliding wear behavior induced by each of the three species. (orig.)

  5. Cochlear implants in children implanted in Jordan: A parental overview.

    Science.gov (United States)

    Alkhamra, Rana A

    2015-07-01

    Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (pparents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.

  6. Sub-meninges implantation reduces immune response to neural implants.

    Science.gov (United States)

    Markwardt, Neil T; Stokol, Jodi; Rennaker, Robert L

    2013-04-15

    Glial scar formation around neural interfaces inhibits their ability to acquire usable signals from the surrounding neurons. To improve neural recording performance, the inflammatory response and glial scarring must be minimized. Previous work has indicated that meningeally derived cells participate in the immune response, and it is possible that the meninges may grow down around the shank of a neural implant, contributing to the formation of the glial scar. This study examines whether the glial scar can be reduced by placing a neural probe completely below the meninges. Rats were implanted with sets of loose microwire implants placed either completely below the meninges or implanted conventionally with the upper end penetrating the meninges, but not attached to the skull. Histological analysis was performed 4 weeks following surgical implantation to evaluate the glial scar. Our results found that sub-meninges implants showed an average reduction in reactive astrocyte activity of 63% compared to trans-meninges implants. Microglial activity was also reduced for sub-meninges implants. These results suggest that techniques that isolate implants from the meninges offer the potential to reduce the encapsulation response which should improve chronic recording quality and stability. Published by Elsevier B.V.

  7. Management of complications of cosmetic iris implants in a phakic eye: a case report and literature review.

    Science.gov (United States)

    Bore, Millicent; Choudhari, Nikhil; Chaurasia, Sunita

    2018-03-21

    To report the intricacies of managing complications that arose out of cosmetic iris implants (BrightOcular) placement. Interventional case report. A thirty-year-old gentleman presented with complaint of progressive loss of vision after having cosmetic iris implant surgery to change his eye colour. He then developed raised intraocular pressures and had a right eye trabeculectomy conducted with the implants in situ. Subsequently, he had implant removal surgery because of persistent implant-associated complications. The vision was impaired due to progressive corneal oedema and glaucoma. Various considerations were taken while planning for surgical intervention because of the extensive structural damage to the anterior segment of the eye. This case report highlights that cosmetic iris implants are dangerous intraocular devices and management of the associated complications is also challenging. As these devices cause irreversible structural and functional damage, their use should be discouraged in normal eyes.

  8. Factors associated with dental implant survival: a 4-year retrospective analysis.

    Science.gov (United States)

    Zupnik, Jamie; Kim, Soo-woo; Ravens, Daniel; Karimbux, Nadeem; Guze, Kevin

    2011-10-01

    Dental implants are a predictable treatment option for replacing missing teeth and have strong survival and success outcomes. However, previous research showed a wide array of potential risk factors that may have contributed to dental implant failures. The objectives of this study are to study if implant survival rates were affected by known risk factors and risk indicators that may have contributed to implant failures. The secondary outcome measures were whether the level of expertise of the periodontal residents affected success rates and how the rate of implant success at the Harvard School of Dental Medicine (HSDM) compared to published standards. A retrospective chart review of patients at the HSDM who had one of two types of rough-surface implants (group A or B) placed by periodontology residents from 2003 to 2006 was performed. Demographic, health, and implant data were collected and analyzed by multimodel analyses to determine failure rates and any factors that may have increased the likelihood of an implant failure. The study cohort included 341 dental implants. The odds ratio for an implant failure was most clearly elevated for diabetes (2.59 implant surface group B (7.84), and male groups (4.01). There was no significant difference regarding the resident experience. The success rate for HSDM periodontology residents was 96.48% during the 4-year study period. This study demonstrates that implant success rates at HSDM fell within accepted published standards, confirmed previously identified risk factors for a failure, and potentially suggested that other acknowledged risk factors could be controlled for. Furthermore, the level of experience of the periodontology resident did not have an impact on survival outcomes.

  9. Medicolegal implications of dental implant therapy.

    Science.gov (United States)

    Rees, Jonathan

    2013-04-01

    Despite the recent economic downturn, the dental implant market continues to grow year on year. Many more dentists are involved in the placement restoration of dental implants and dental implants are being placed in an extended range of clinical scenarios. Dental implant therapy remains a high risk area for the inexperienced interns of civil negligence claims and General Dental Council hearings. Risk can be mitigated by:• Ensuring appropriate indemnity • Complying with the published requirements for training • Maintaining detailed and extensive clinical records • Completing the initial phases of history, examination and investigations robustly • Recording a diagnosis • Providing a bespoke written treatment plan that includes details of the need for treatment, the treatment options (the risks and benefits), the phases of treatment, the costs of treatment,the expected normal sequelae of surgery, the risks and complications of implant therapy and the requirement for future maintenance. The provision of treatment that is different in nature or extent to that agreed can result in a breach of contract as well as a claim for negligence • Engaging sufficiently with the patient to obtain consent • Providing written postoperative instructions detailing emergency arrangements, patients who are anxious or in pain may not retain oral information • Making a frank disclosure of complication or collateral damage • Considering referral at an early stage particularly if reparative surgery is required. The stress of complications or failure may impair a dentist's normally sound judgement; there may be financial pressure, or concerns regarding reputation. In some cases, dentists avoid making a frank disclosure, feel obliged to undertake complicated reparative surgery, fail to make a timely referral, fail to respond appropriately to patient's concerns and in some cases attempt to alter the clinical records.However, in the best of hands and without negligence

  10. Elevation of the diaphragmatic cupola

    International Nuclear Information System (INIS)

    Semenov, V.M.; Talesnik, M.R.

    1988-01-01

    Altogether 45 patients with elevation of the diaphragmatic cupola were examined. A high frequency of erroneous initial interpretation of examination results was noted in inflammatory and tumorous lesions and congenital conditions. Routine and contrast methods (pneumoperitoneum, bronchography, pleurography and fistulography) were used. Disease-related methods of X-ray investigation were proposed. A variety of causes of diaphragm elevation was indicated

  11. Improving osseointegration of dental implants.

    Science.gov (United States)

    Elias, Carlos Nelson; Meirelles, Luiz

    2010-03-01

    In the beginning of implantology, the procedures adopted for treating patients were performed in two surgical phases with an interval of 3-6 months. Nowadays, it is possible to insert and load a dental implant in the same surgical procedure. This change is due to several factors, such as improvement of surgical technique, modifications of the implant design, increased quality of implant manufacturing, development of the surgical instruments' quality, careful patient screening and adequate treatment of the implant surface. The clinical results show that adequate treatment of surfaces is crucial for reducing healing time and treating at-risk patients. The surface properties of dental implants can be significantly improved at the manufacturing stage, affecting cells' activity during the healing phase that will ultimately determine the host tissue response, a fundamental requirement for clinical success. This review focuses on different types of dental implant surfaces and the influence of surface characteristics on osseointegration.

  12. Adipose tissue-derived microvascular fragments from aged donors exhibit an impaired vascularisation capacity

    Directory of Open Access Journals (Sweden)

    MW Laschke

    2014-10-01

    Full Text Available Adipose tissue-derived microvascular fragments are promising vascularisation units for applications in the field of tissue engineering. Elderly patients are the major future target population of such applications due to an increasing human life expectancy. Therefore, we herein investigated the effect of aging on the fragments’ vascularisation capacity. Microvascular fragments were isolated from epididymal fat pads of adult (8 months and aged (16 months C57BL/6 donor mice. These fragments were seeded onto porous polyurethane scaffolds, which were implanted into dorsal skinfold chambers to study their vascularisation using intravital fluorescence microscopy, histology and immunohistochemistry. Scaffolds seeded with fragments from aged donors exhibited a significantly lower functional microvessel density and intravascular blood flow velocity. This was associated with an impaired vessel maturation, as indicated by vessel wall irregularities, constantly elevated diameters and a lower fraction of CD31/α-smooth muscle actin double positive microvessels in the implants’ border and centre zones. Additional in vitro analyses revealed that microvascular fragments from adult and aged donors do not differ in their stem cell content as well as in their release of angiogenic growth factors, survival and proliferative activity under hypoxic conditions. However, fragments from aged donors exhibit a significantly lower number of matrix metalloproteinase -9-positive perivascular cells. Taken together, these findings demonstrate that aging is a crucial determinant for the vascularisation capacity of isolated microvascular fragments.

  13. Space Station tethered elevator system

    Science.gov (United States)

    Haddock, Michael H.; Anderson, Loren A.; Hosterman, K.; Decresie, E.; Miranda, P.; Hamilton, R.

    1989-01-01

    The optimized conceptual engineering design of a space station tethered elevator is presented. The tethered elevator is an unmanned, mobile structure which operates on a ten-kilometer tether spanning the distance between Space Station Freedom and a platform. Its capabilities include providing access to residual gravity levels, remote servicing, and transportation to any point along a tether. The report discusses the potential uses, parameters, and evolution of the spacecraft design. Emphasis is placed on the elevator's structural configuration and three major subsystem designs. First, the design of elevator robotics used to aid in elevator operations and tethered experimentation is presented. Second, the design of drive mechanisms used to propel the vehicle is discussed. Third, the design of an onboard self-sufficient power generation and transmission system is addressed.

  14. The comparison of balance performance among children with cochlear implantation, post-aural aid and normal children

    Directory of Open Access Journals (Sweden)

    Arezoo Ahmad pour

    2014-11-01

    Full Text Available Background: This cross-sectional study was carried out to compare balance performance between children with cochlear implants and post-aural aid and normal children. Methods: The present study was done on 67 severe to profound hearing impaired children. Of these, 21 children with an average age of 7 years and 4 months (±1.7 wore cochlear implant, 46 children with an average age of 7 years and 7 months (±1.7 wore post-aural aid and 60 children with an average 8 years and one month (±11 months were considered as a control group. All of the children were tested with the 9-stage balance subtest of Bruininks-Oseretsky Test of Motor Proficiency2 (BOT2. Results: The mean total BOT2 score of hearing impaired children was significantly lower than the normal group (P≤0.001. The mean total BOT2 score among children with cochlear implant, post-aural aids and normal group showed that cochlear implant group significantly performed weaker than the other two groups (P≤0.001. Conclusion: Hearing impaired children particularly children with cochlear implant are exposed to the risk of balance deficit. Hearing impaired children specially those who wear cochlear implants must be screened for vestibular hypofunction.

  15. Effects of Elevated Ambient Temperature on Reproductive Outcomes and Offspring Growth Depend on Exposure Time

    Directory of Open Access Journals (Sweden)

    Huda Yahia Hamid

    2012-01-01

    Full Text Available Reproductive performance has been shown to be greatly affected by changes in environmental factors, such as temperature. However, it is also crucial to identify the particular stage of pregnancy that is most adversely affected by elevated ambient temperature. The aims of this study were to determine the effect on reproductive outcomes of exposure to elevated ambient temperature during different stages of pregnancy and to determine the effect of prenatal heat stress on offspring growth. Sixty pregnant rats were used in this study. The rats were divided equally into four groups as group 1 (control, group 2 (exposed to elevated temperature following implantation, group 3 (exposed to elevated temperature during pre- and periimplantation, and group 4 (exposed to elevated temperature during pre- and periimplantation and following implantation. Groups 3 and 4 had prolonged gestation periods, reduced litter sizes, and male-biased sex ratios. Moreover, the growth patterns of group 3 and 4 pups were adversely affected by prenatal exposure to elevated temperature. The differences between group 1 and group 3 and between group 1 and group 4 were highly significant. However, no significant differences were observed between groups 1 and 2 in the gestation length, sex ratios, and growth patterns. Thus, it can be concluded that exposure to elevated ambient temperature during pre- and periimplantation has stronger adverse effects on reproductive outcomes and offspring growth than postimplantation exposure.

  16. Congenital hearing impairment

    Energy Technology Data Exchange (ETDEWEB)

    Robson, Caroline D. [Children' s Hospital and Harvard Medical School, Division of Neuroradiology, Department of Radiology, Boston, MA (United States)

    2006-04-15

    Establishing the etiology of congenital hearing impairment can significantly improve treatment for certain causes of hearing loss and facilitates genetic counseling. High-resolution CT and MRI have contributed to the evaluation and management of hearing impairment. In addition, with the identification of innumerable genetic loci and genetic defects involved in hearing loss, genetic testing has emerged as an invaluable tool in the assessment of hearing impairment. Some of the common forms of congenital hearing loss are reviewed and their imaging features illustrated. (orig.)

  17. Congenital hearing impairment

    International Nuclear Information System (INIS)

    Robson, Caroline D.

    2006-01-01

    Establishing the etiology of congenital hearing impairment can significantly improve treatment for certain causes of hearing loss and facilitates genetic counseling. High-resolution CT and MRI have contributed to the evaluation and management of hearing impairment. In addition, with the identification of innumerable genetic loci and genetic defects involved in hearing loss, genetic testing has emerged as an invaluable tool in the assessment of hearing impairment. Some of the common forms of congenital hearing loss are reviewed and their imaging features illustrated. (orig.)

  18. Immediate Direct-To-Implant Breast Reconstruction Using Anatomical Implants

    Directory of Open Access Journals (Sweden)

    Sung-Eun Kim

    2014-09-01

    Full Text Available BackgroundIn 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience.MethodsFrom November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction.ResultsThe mean breast resection volume was 240 mL (range, 83-540 mL. The mean size of the breast implants was 217 mL (range, 125-395 mL. Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen.ConclusionsBy using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.

  19. Dental implants in growing children

    Directory of Open Access Journals (Sweden)

    S K Mishra

    2013-01-01

    Full Text Available The replacement of teeth by implants is usually restricted to patients with completed craniofacial growth. The aim of this literature review is to discuss the use of dental implants in normal growing patients and in patients with ectodermal dysplasia and the influence of maxillary and mandibular skeletal and dental growth on the stability of those implants. It is recommended that while deciding the optimal individual time point of implant insertion, the status of skeletal growth, the degree of hypodontia, and extension of related psychological stress should be taken into account, in addition to the status of existing dentition and dental compliance of a pediatric patient.

  20. Printing of Titanium implant prototype

    International Nuclear Information System (INIS)

    Wiria, Florencia Edith; Shyan, John Yong Ming; Lim, Poon Nian; Wen, Francis Goh Chung; Yeo, Jin Fei; Cao, Tong

    2010-01-01

    Dental implant plays an important role as a conduit of force and stress to flow from the tooth to the related bone. In the load sharing between an implant and its related bone, the amount of stress carried by each of them directly related to their stiffness or modulus. Hence, it is a crucial issue for the implant to have matching mechanical properties, in particular modulus, between the implant and its related bone. Titanium is a metallic material that has good biocompatibility and corrosion resistance. Whilst the modulus of the bulk material is still higher than that of bone, it is the lowest among all other commonly used metallic implant materials, such as stainless steel or cobalt alloy. Hence it is potential to further reduce the modulus of pure Titanium by engineering its processing method to obtain porous structure. In this project, porous Titanium implant prototype is fabricated using 3-dimensional printing. This technique allows the flexibility of design customization, which is beneficial for implant fabrication as tailoring of implant size and shape helps to ensure the implant would fit nicely to the patient. The fabricated Titanium prototype had a modulus of 4.8-13.2 GPa, which is in the range of natural bone modulus. The compressive strength achieved was between 167 to 455 MPa. Subsequent cell culture study indicated that the porous Titanium prototype had good biocompatibility and is suitable for bone cell attachment and proliferation.

  1. Cochlear implantation in Mondini dysplasia.

    Science.gov (United States)

    Daneshi, Ahmad; Hassanzadeh, Saeid; Abasalipour, Parvaneh; Emamdjomeh, Hessamaddin; Farhadi, Mohammad

    2003-01-01

    The use of cochlear implantation to treat patients with inner ear malformations such as Mondini dysplasia has been increasingly successful. Until now, conventional hearing aids in these patients have not performed well. Consequently, the hearing problem for patients with this condition has been somewhat improved with the use of cochlear implants. Various results of cochlear implantation have been reported in these patients so far. This is a report of 5 patients with Mondini malformation who have undergone cochlear implant surgery. Copyright 2003 S. Karger AG, Basel

  2. Implant-retained maxillary overdentures.

    Science.gov (United States)

    Eckert, Steven E; Carr, Alan B

    2004-07-01

    Overdentures supported by osseointegrated implants overcome many of the complications observed with overdentures supported by natural teeth. Dental implants are free of biologic consequences associated with natural teeth, such as dental caries and periodontal disease. Bone undercuts adjacent to implants do not mimic those found adjacent to natural tooth roots. Implants are used to provide predictable retention, support, and stability for overdenture prostheses. When lip or facial support is required, the overdenture is the treatment of choice. Likewise the overdenture may improve phonetic deficiencies associated with alveolar bone loss.

  3. Cochlear implants in Waardenburg syndrome.

    Science.gov (United States)

    Cullen, Robert D; Zdanski, Carlton; Roush, Patricia; Brown, Carolyn; Teagle, Holly; Pillsbury, Harold C; Buchman, Craig

    2006-07-01

    Waardenburg syndrome is an autosomal-dominant syndrome characterized by dystopia canthorum, hyperplasia of the eyebrows, heterochromia irides, a white forelock, and sensorineural hearing loss in 20% to 55% of patients. This patient population accounts for approximately 2% of congenitally deaf children. The purpose of this retrospective case review was to describe the outcomes for those children with Waardenburg syndrome who have undergone cochlear implantation. Pediatric cochlear implant recipients with documented evidence of Waardenburg syndrome underwent retrospective case review. All patients received their cochlear implants at the study institution followed by outpatient auditory habilitation. Charts were reviewed for etiology and duration of deafness, age at time of cochlear implantation, perioperative complications, duration of use, and performance outcomes. Results of standard tests batteries for speech perception and production administered as a part of the patients' auditory habilitation were reviewed. Seven patients with Waardenburg syndrome and cochlear implants were identified. The average age at implantation was 37 months (range, 18-64 months) and the average duration of use was 69 months (range, 12-143 months). All of these patients are active users of their devices and perform very well after implantation. There were no major complications in this small group of patients. Children with congenital sensorineural hearing loss without other comorbidities (e.g., developmental delay, inner ear malformations) perform well when they receive cochlear implantation and auditory habilitation. Patients with Waardenburg syndrome can be expected to have above-average performance after cochlear implantation.

  4. Sensation Following Immediate Breast Reconstruction with Implants.

    Science.gov (United States)

    Lagergren, Jakob; Wickman, Marie; Hansson, Per

    2010-01-01

    Sensation is a neglected aspect of the outcome of breast reconstructions with implants. The aim of this prospective study was to evaluate the cutaneous somatosensory status in breasts following mastectomy and immediate reconstruction with permanent adjustable prostheses and to analyze the patients' subjective experience of the sensation. Twenty-four consecutive patients diagnosed with invasive or in situ breast carcinoma were examined preoperatively and 2 years after mastectomy and reconstruction, for assessment of perception thresholds for touch, cold, warmth, and heat pain above and below the areola. Von Frey filaments and a Peltier element-based thermode were used. The patients completed a questionnaire concerning their experienced sensation in the reconstructed breast. Using quantitative somato-sensory testing, the sensation to all the examined modalities was significantly impaired compared to preoperatively. Most affected was the area above the areola. Patients given postoperative radiotherapy (n = 9) did not differ from those without radiotherapy (n = 15) regarding any of the modalities. All patients reported reduced sensation in the reconstructed breast compared to that preoperatively. Twenty-three patients stated that the reconstructed breast felt different from the other breast; nevertheless 16 reported that the reconstructed breast felt like a real breast. The study revealed sensation impairment following mastectomy and immediate reconstruction with implants. Patients should be informed about this effect preoperatively to allow adequate expectations regarding the sensation outcome. However, two-thirds of the study patients considered that the reconstructed breast felt like a real breast, which must be one of the main purposes of a breast reconstruction.

  5. Patient benefit from seamless implant monitoring

    Directory of Open Access Journals (Sweden)

    Karsten Wallbrück

    2005-12-01

    Full Text Available Background: Patients with electrostimulation devices visit the hospital regularly for follow-up. The workload of out-patient departments is ever increasing, but a less frequent check-up is unwanted, as it could impair reliability and effectiveness of the therapy. A system of remote patient monitoring might improve this situation by enabling identification of patients who benefit from a shortened time for corrective action after any undesired event. A completely automatic system for patient remote monitoring has been introduced (BIOTRONIK Home Monitoring, HM. Daily patient and device data are displayed on an internet site which allows authorized persons to follow the parameters trends. Several clinical studies are presently being conducted to investigate the benefit of HM in pacemaker and implantable cardioverter/defibrillator therapy. Preliminary results show the system’s ability to individualize implant therapy for the patients’ and the physicians’ benefits. Previous studies in heart failure (HF therapy have shown that hospital readmission rates, hospitalisation duration and also mortality can be reduced by patient monitoring programs. A recently started study investigating HM in heart failure therapy aims to define a HF-indicator that predicts a worsening of the patient’s status leading to hospitalisation. With such an indicator, the responsible physician could be alerted and the patient can be called in. Although several issues connected to Home Monitoring remain to be solved, the time has come for a more flexible patient management. The incorporation of modern information technology into cardiovascular implants offers a way to solve the conflict between limited resources and high quality medical therapy for an aging population.

  6. Esthetic, functional, and prosthetic outcomes with implant-retained finger prostheses.

    Science.gov (United States)

    Aydin, Cemal; Nemli, Secil Karakoca; Yilmaz, Handan

    2013-04-01

    Traumatic amputation of fingers results in a serious impairment of hand function and affects the psychological status of the patients. The implant-retained finger prostheses are an alternative treatment. The aim of this case report is to represent the use of osseointegrated implants for retention of finger prostheses in a patient with amputated thumb and index finger. Dental implants were placed in the residual bone of the fingers using two-stage surgery. Custom-made attachments were used to provide retention between implants and silicone prostheses. Prosthetic fingernails were made of composite resin material. After 6 months, implants were clinically successful, and the patient was satisfied with the appearance and the function of the prostheses. The complications of broken prosthetic nail and mild discoloration were observed. Reconstruction of amputated fingers with implant-retained prosthesis is a worthwhile treatment providing esthetic, functional, and psychological benefits, although some complications might be experienced. Clinical relevance Implant-retained finger prostheses are an acceptable treatment modality for patients with amputated fingers. Evaluating implant prognosis, functional results and prosthetic results of the patients are necessary to address the benefits and complications of the treatment.

  7. Silicone implant correction of pectus excavatum.

    Science.gov (United States)

    Wechselberger, G; Ohlbauer, M; Haslinger, J; Schoeller, T; Bauer, T; Piza-Katzer, H

    2001-11-01

    Between May 1989 and December 2000 in 24 adult patients with pectus excavatum, a subcutaneous implantation of silicone prostheses was performed. Of the 24 patients, 20 were followed. During follow-up the authors encountered seroma complications in 13 patients and postoperative hematoma in 4 patients. The patients stayed in the hospital 5 days on average, and showed excellent aesthetic results in 80% (N = 16), good results in 10% (N = 2), and fair results in 10% (N = 2). Patient satisfaction was also taken into consideration. A follow-up survey questioned whether patients were satisfied with the cosmetic outcome. On a scale of 1 to 5 points, with 1 point being the highest level of satisfaction, 85% of patients used ratings of 1 and 2 to express satisfaction levels. Silicone implant correction of pectus excavatum in adult patients without any impairment of cardiopulmonary function has value. The major advantages are the minimally invasive operation, the short hospital stay, good aesthetic results, and high patient satisfaction

  8. Dissociation between learning and memory impairment and other sickness behaviours during simulated Mycoplasma infection in rats.

    Science.gov (United States)

    Swanepoel, Tanya; Harvey, Brian H; Harden, Lois M; Laburn, Helen P; Mitchell, Duncan

    2011-11-01

    To investigate potential consequences for learning and memory, we have simulated the effects of Mycoplasma infection, in rats, by administering fibroblast-stimulating lipopepide-1 (FSL-1), a pyrogenic moiety of Mycoplasma salivarium. We measured the effects on body temperature, cage activity, food intake, and on spatial learning and memory in a Morris Water Maze. Male Sprague-Dawley rats had radio transponders implanted to measure abdominal temperature and cage activity. After recovery, rats were assigned randomly to receive intraperitoneal (I.P.) injections of FSL-1 (500 or 1000 μg kg(-1) in 1 ml kg(-1) phosphate-buffered saline; PBS) or vehicle (PBS, 1 ml kg(-1)). Body mass and food intake were measured daily. Training in the Maze commenced 18 h after injections and continued daily for four days. Spatial memory was assessed on the fifth day. In other rats, we measured concentrations of brain pro-inflammatory cytokines, interleukin (IL)-1β and IL-6, at 3 and 18 h after injections. FSL-1 administration induced a dose-dependent fever (∼1°C) for two days, lethargy (∼78%) for four days, anorexia (∼65%) for three days and body mass stunting (∼6%) for at least four days. Eighteen hours after FSL-1 administration, when concentrations of IL-1β, but not that of IL-6, were elevated in both the hypothalamus and the hippocampus, and when rats were febrile, lethargic and anorexic, learning in the Maze was unaffected. There also was no memory impairment. Our results support emerging evidence that impaired learning and memory is not inevitable during simulated infection. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. Impairments to Vision

    Science.gov (United States)

    ... an external Non-Government web site. Impairments to Vision Normal Vision Diabetic Retinopathy Age-related Macular Degeneration In this ... pictures, fixate on the nose to simulate the vision loss. In diabetic retinopathy, the blood vessels in ...

  10. Stormwater Impaired Watersheds

    Data.gov (United States)

    Vermont Center for Geographic Information — Stormwater impaired watersheds occuring on both the Priority Waters (Part D - Completed TMDL) and 303(d) list of waters (Part A - need TMDL) The Vermont State...

  11. Age at implantation and auditory memory in cochlear implanted children.

    Science.gov (United States)

    Mikic, B; Miric, D; Nikolic-Mikic, M; Ostojic, S; Asanovic, M

    2014-05-01

    Early cochlear implantation, before the age of 3 years, provides the best outcome regarding listening, speech, cognition an memory due to maximal central nervous system plasticity. Intensive postoperative training improves not only auditory performance and language, but affects auditory memory as well. The aim of this study was to discover if the age at implantation affects auditory memory function in cochlear implanted children. A total of 50 cochlear implanted children aged 4 to 8 years were enrolled in this study: early implanted (1-3y) n = 27 and late implanted (4-6y) n = 23. Two types of memory tests were used: Immediate Verbal Memory Test and Forward and Backward Digit Span Test. Early implanted children performed better on both verbal and numeric tasks of auditory memory. The difference was statistically significant, especially on the complex tasks. Early cochlear implantation, before the age of 3 years, significantly improve auditory memory and contribute to better cognitive and education outcomes.

  12. Context-Aware Elevator Scheduling

    OpenAIRE

    Strang, Thomas; Bauer, Christian

    2007-01-01

    Research on context-aware systems is usually user-centric and thus focussed on the context of a specific user to serve his or her needs in an optimized way. In this paper, we want to apply core concepts developed in research on context-awareness in a system-centric way, namely to elevator systems. We show with three different examples that the performance of an elevator system can be significantly improved if the elevator control has access to contextual knowledge. The first example demons...

  13. Elevation of B-Type Natriuretic Peptide at Discharge is Associated With 2-Year Mortality After Transcatheter Aortic Valve Replacement in Patients With Severe Aortic Stenosis: Insights From a Multicenter Prospective OCEAN-TAVI (Optimized Transcatheter Valvular Intervention-Transcatheter Aortic Valve Implantation) Registry.

    Science.gov (United States)

    Mizutani, Kazuki; Hara, Masahiko; Iwata, Shinichi; Murakami, Takashi; Shibata, Toshihiko; Yoshiyama, Minoru; Naganuma, Toru; Yamanaka, Futoshi; Higashimori, Akihiro; Tada, Norio; Takagi, Kensuke; Araki, Motoharu; Ueno, Hiroshi; Tabata, Minoru; Shirai, Shinichi; Watanabe, Yusuke; Yamamoto, Masanori; Hayashida, Kentaro

    2017-07-14

    In this study, we sought to investigate the 2-year prognostic impact of B-type natriuretic peptide (BNP) levels at discharge, following transcatheter aortic valve replacement. We enrolled 1094 consecutive patients who underwent transcatheter aortic valve replacement between 2013 and 2016. Study patients were stratified into 2 groups according to survival classification and regression tree analysis (high versus low BNP groups). We evaluated the impact of high BNP on 2-year mortality compared with that of low BNP using a multivariable Cox model, and assessed whether this stratification would improve predictive accuracy for determining 2-year mortality by assessing time-dependent net reclassification improvement and integrated discrimination improvement. The median age of patients was 85 years (quartile 82-88), and 29.2% of the study population were men. The median Society of Thoracic Surgeons score was 6.8 (4.7-9.5), and BNP at discharge was 186 (93-378) pg/mL. All-cause mortality following discharge was 7.9% (95% CI, 5.8-9.9%) at 1 year and 15.4% (95% CI, 11.6-19.0%) at 2 years. The survival classification and regression tree analysis revealed that the discriminating BNP level to discern 2-year mortality was 202 pg/mL, and that elevated BNP had a statistically significant impact on outcomes, with an adjusted hazard ratio of 2.28 (1.36-3.82, P =0.002). The time-dependent net reclassification improvement ( P =0.047) and integrated discrimination improvement ( P =0.029) analysis revealed that the incorporation of BNP stratification with other clinical variables significantly improved predictive accuracy for 2-year mortality. Elevation of BNP at discharge is associated with 2-year mortality after transcatheter aortic valve replacement. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  14. Fixation of revision implants is improved by a surgical technique to crack the sclerotic bone rim.

    Science.gov (United States)

    Kold, Søren; Bechtold, Joan E; Mouzin, Olivier; Elmengaard, Brian; Chen, Xinqian; Søballe, Kjeld

    2005-03-01

    Revision joint replacement has poorer outcomes compared with primary joint replacement, and these poor outcomes have been associated with poorer fixation. We investigated a surgical technique done during the revision operation to improve access from the marrow space to the implant interface by locally cracking the sclerotic bone rim that forms during aseptic loosening. Sixteen implants were inserted bilaterally by distal femur articulation of the knee joint of eight dogs, using our controlled experimental model that replicates the revision setting (sclerotic bone rim, dense fibrous tissue, macrophages, elevated cytokines) by pistoning a loaded 6.0-mm implant 500 microm into the distal femur with particulate PE. At 8 weeks, one of two revision procedures was done. Both revision procedures included complete removal of the membrane, scraping, lavaging, and inserting a revision plasma-spray Ti implant. The crack revision procedure also used a splined tool to circumferentially locally perforate the sclerotic bone rim before insertion of an identical revision implant. Superior fixation was achieved with the cracking procedure in this experimental model. Revision implants inserted with the rim cracking procedure had a significantly higher pushout strength (fivefold median increase) and energy to failure (sixfold median increase), compared with the control revision procedure. Additional evaluation is needed of local perforation of sclerotic bone rim as a simple bone-sparing means to improve revision implant fixation and thereby increase revision implant longevity.

  15. Alveolar nerve repositioning with rescue implants for management of previous treatment. A clinical report.

    Science.gov (United States)

    Amet, Edward M; Uehlein, Chris

    2013-12-01

    The goal of modern implant dentistry is to return patients to oral health in a rapid and predictable fashion, following a diagnostically driven treatment plan. If only a limited number of implants can be placed, or some fail and the prosthetic phase of implant dentistry is chosen to complete the patient's treatment, the final outcome may result in partial patient satisfaction and is commonly referred to as a "compromise." Previous All-on-4 implant treatment for the patient presented here resulted in a compromise, with an inadequate support system for the mandibular prosthesis and a maxillary complete denture with poor esthetics. The patient was unable to function adequately and also was disappointed with the resulting appearance. Correction of the compromised treatment consisted of bilateral inferior alveolar nerve elevation and repositioning without bone removal for lateral transposition, to gain room for rescue implants for a totally implant-supported and stabilized prosthesis. Treatment time to return the patient to satisfactory comfort, function, facial esthetics, and speech was approximately 2 weeks. The definitive mandibular prosthesis was designed for total implant support and stability with patient retrievability. Adequate space between the mandibular bar system and the soft tissue created a high water bridge effect for self-cleansing. Following a short interim mandibular healing period, the maxillary sinuses were bilaterally grafted to compensate for bone inadequacies and deficiencies for future maxillary implant reconstruction. © 2013 by the American College of Prosthodontists.

  16. Cobalt-alloy implant debris induce HIF-1α hypoxia associated responses: a mechanism for metal-specific orthopedic implant failure.

    Directory of Open Access Journals (Sweden)

    Lauryn Samelko

    Full Text Available The historical success of orthopedic implants has been recently tempered by unexpected pathologies and early failures of some types of Cobalt-Chromium-Molybdenum alloy containing artificial hip implants. Hypoxia-associated responses to Cobalt-alloy metal debris were suspected as mediating this untoward reactivity at least in part. Hypoxia Inducible Factor-1α is a major transcription factor involved in hypoxia, and is a potent coping mechanism for cells to rapidly respond to changing metabolic demands. We measured signature hypoxia associated responses (i.e. HIF-1α, VEGF and TNF-α to Cobalt-alloy implant debris both in vitro (using a human THP-1 macrophage cell line and primary human monocytes/macrophages and in vivo. HIF-1α in peri-implant tissues of failed metal-on-metal implants were compared to similar tissues from people with metal-on-polymer hip arthroplasties, immunohistochemically. Increasing concentrations of cobalt ions significantly up-regulated HIF-1α with a maximal response at 0.3 mM. Cobalt-alloy particles (1 um-diameter, 10 particles/cell induced significantly elevated HIF-1α, VEGF, TNF-α and ROS expression in human primary macrophages whereas Titanium-alloy particles did not. Elevated expression of HIF-1α was found in peri-implant tissues and synovial fluid of people with failing Metal-on-Metal hips (n = 5 compared to failed Metal-on-Polymer articulating hip arthroplasties (n = 10. This evidence suggests that Cobalt-alloy, more than other metal implant debris (e.g. Titanium alloy, can elicit hypoxia-like responses that if unchecked can lead to unusual peri-implant pathologies, such as lymphocyte infiltration, necrosis and excessive fibrous tissue growths.

  17. A Longitudinal Study of Pragmatic Language Development in Three Children with Cochlear Implants

    Science.gov (United States)

    Dammeyer, Jesper

    2012-01-01

    Research has shown how cochlear implants (CIs), in children with hearing impairments, have improved speech perception and production, but very little is known about the children's pragmatic language development. During a 4-year longitudinal study of three children with CIs, certain aspects of pragmatic language development were observed in free…

  18. Transcatheter aortic valve implantation: emerging role in poor left ventricular function severe aortic stenosis?

    Directory of Open Access Journals (Sweden)

    K. M. John Chan

    2014-01-01

    Full Text Available Transcatheter aortic valve implantation (TAVI has become an established treatment option for high risk elderly patients with symptomatic severe aortic stenosis. Its role in less high risk patients is being evaluated in clinical trials. Patients with severely impaired left ventricular function may be another group who may benefit from this emerging percutaneous treatment option.

  19. Cluster Implantation and Deposition Apparatus

    DEFF Research Database (Denmark)

    Hanif, Muhammad; Popok, Vladimir

    2015-01-01

    In the current report, a design and capabilities of a cluster implantation and deposition apparatus (CIDA) involving two different cluster sources are described. The clusters produced from gas precursors (Ar, N etc.) by PuCluS-2 can be used to study cluster ion implantation in order to develop...

  20. Porous metal for orthopedics implants

    OpenAIRE

    Matassi, Fabrizio; Botti, Alessandra; Sirleo, Luigi; Carulli, Christian; Innocenti, Massimo

    2013-01-01

    Porous metal has been introduced to obtain biological fixation and improve longevity of orthopedic implants. The new generation of porous metal has intriguing characteristics that allows bone healing and high osteointegration of the metallic implants. This article gives an overview about biomaterials properties of the contemporary class of highly porous metals and about the clinical use in orthopaedic surgery.

  1. [The impact of dental implants

    NARCIS (Netherlands)

    Meijer, G.J.

    2013-01-01

    The importance of the introduction of dental implants can only be understood when the historical context is clarified. In the past, the main treatment carried out by dentists consisted of filling or, in unfortunate cases, removal of painful teeth. Only since the introduction of dental implants did

  2. Sequential provisional implant prosthodontics therapy.

    Science.gov (United States)

    Zinner, Ira D; Markovits, Stanley; Jansen, Curtis E; Reid, Patrick E; Schnader, Yale E; Shapiro, Herbert J

    2012-01-01

    The fabrication and long-term use of first- and second-stage provisional implant prostheses is critical to create a favorable prognosis for function and esthetics of a fixed-implant supported prosthesis. The fixed metal and acrylic resin cemented first-stage prosthesis, as reviewed in Part I, is needed for prevention of adjacent and opposing tooth movement, pressure on the implant site as well as protection to avoid micromovement of the freshly placed implant body. The second-stage prosthesis, reviewed in Part II, should be used following implant uncovering and abutment installation. The patient wears this provisional prosthesis until maturation of the bone and healing of soft tissues. The second-stage provisional prosthesis is also a fail-safe mechanism for possible early implant failures and also can be used with late failures and/or for the necessity to repair the definitive prosthesis. In addition, the screw-retained provisional prosthesis is used if and when an implant requires removal or other implants are to be placed as in a sequential approach. The creation and use of both first- and second-stage provisional prostheses involve a restorative dentist, dental technician, surgeon, and patient to work as a team. If the dentist alone cannot do diagnosis and treatment planning, surgery, and laboratory techniques, he or she needs help by employing the expertise of a surgeon and a laboratory technician. This team approach is essential for optimum results.

  3. Labyrinthectomy with cochlear implantation.

    Science.gov (United States)

    Zwolan, T A; Shepard, N T; Niparko, J K

    1993-05-01

    Numerous reports indicate that the cochlea remains responsive to electrical stimulation following labyrinthectomy. We report a case of a 47-year-old woman with a severe to profound sensorineural hearing loss from birth, who developed episodic vertigo with symptoms suggestive of delayed onset endolymphatic hydrops. Following 8 months of failed medical and vestibular rehabilitation management, a right-sided labyrinthectomy combined with cochlear implantation was performed without complication. Postoperatively the patient was free of vertigo. Attempts to activate the patient's device between 4 to 12 weeks after surgery were unsuccessful as stimulation of the electrodes resulted in discomfort. However, all 20 electrodes elicited comfortable hearing sensations 16 weeks postsurgery. One year after the successful activation, the patient demonstrated improved sound awareness and speech recognition with the implant when compared with preoperative performance with a hearing aid. This case study suggests that electrical detection thresholds with prosthetic stimulation may be unstable in the recently labyrinthectomized ear but supports and extends prior observations of preserved cochlear responsiveness after labyrinthectomy.

  4. FEMA DFIRM Base Flood Elevations

    Data.gov (United States)

    Minnesota Department of Natural Resources — The Base Flood Elevation (BFE) table is required for any digital data where BFE lines will be shown on the corresponding Flood Insurance Rate Map (FIRM). Normally,...

  5. Advanced energy saving hydraulic elevator

    Energy Technology Data Exchange (ETDEWEB)

    Garrido, A.; Sevilleja, J.; Servia, A.

    1993-08-24

    An hydraulic elevator is described comprising: a counterweighted elevator comprising a car, a counterweight, and a rope connecting the car and the counterweight; a ram having a first reaction surface for driving one of the car or the counterweight upwardly and a second reaction surface for driving one of the car or the counterweight downwardly; multiplier means for moving the car a distance greater than a stroke of the ram, the multiplier means connecting the ram to the counterweighted elevator, the multiplier means comprising: a first pulley; a second pulley; means for rigidly connecting the first and second pulley, the means having a length corresponding to a rise of the hydraulic elevator, the means attaching to the ram; and a pulley rope which: has a first end attaching to a first fixed point, extends about the first pulley, extends about the second pulley, and has a second end attaching to a second fixed point.

  6. Space Elevators Preliminary Architectural View

    Science.gov (United States)

    Pullum, L.; Swan, P. A.

    Space Systems Architecture has been expanded into a process by the US Department of Defense for their large scale systems of systems development programs. This paper uses the steps in the process to establishes a framework for Space Elevator systems to be developed and provides a methodology to manage complexity. This new approach to developing a family of systems is based upon three architectural views: Operational View OV), Systems View (SV), and Technical Standards View (TV). The top level view of the process establishes the stages for the development of the first Space Elevator and is called Architectural View - 1, Overview and Summary. This paper will show the guidelines and steps of the process while focusing upon components of the Space Elevator Preliminary Architecture View. This Preliminary Architecture View is presented as a draft starting point for the Space Elevator Project.

  7. Coastal Digital Elevation Models (DEMs)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Digital elevation models (DEMs) of U.S. and other coasts that typically integrate ocean bathymetry and land topography. The DEMs support NOAA's mission to understand...

  8. Base Flood Elevation (BFE) Lines

    Data.gov (United States)

    Department of Homeland Security — The Base Flood Elevation (BFE) table is required for any digital data where BFE lines will be shown on the corresponding Flood Insurance Rate Map (FIRM). Normally if...

  9. Elevated Fixed Platform Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Elevated Fixed Platform (EFP) is a helicopter recovery test facility located at Lakehurst, NJ. It consists of a 60 by 85 foot steel and concrete deck built atop...

  10. Energy efficient elevators and escalators

    Energy Technology Data Exchange (ETDEWEB)

    Patrao, Carlos; Fong, Joao; Almeida, Anibal de (Dep. Electrical Engineering, Univ. of Coimbra, Coimbra (Portugal)); Rivet, Luc

    2009-07-01

    Elevators and escalators are the crucial element that makes it practical to live and work several floors above ground - more than 4,3 million units are installed in Europe. Due to ageing of the European population the installation of elevators in single family houses is experiencing a significant growth, as well as equipping existing buildings. Elevators use about 4% of the electricity in tertiary sector buildings. High untapped saving potentials exist with respect to energy-efficient technologies, investment decisions and behavioural approaches, in these sectors. This paper presents preliminary results from the IEE project E4, whose overall objective is the improvement of the energy performance of elevators and escalators, in tertiary sector buildings and in multi family residential buildings. The project is characterizing people conveyors electricity consumption in the tertiary sector and in residential buildings in the EU. The installed park is characterised by a survey among elevators national associations in each country. An assessment of the barriers has been made in the first phase of the project and will be presented. Monitoring campaigns in elevators and escalators are being conducted in each country according to a common developed methodology. More than fifty elevators and escalators will be audited. This will allow the collection of load curves (start up, travel up and down, travel full and empty), including the characterization of standby consumption. Standby consumption of an elevator can represent up to 80% of the total energy consumed per year, and can be drastically reduced. This paper presents the preliminary results of the first ten audits performed in Portugal by Isr-UC.

  11. Ion implantation and amorphous metals

    International Nuclear Information System (INIS)

    Hohmuth, K.; Rauschenbach, B.

    1981-01-01

    This review deals with ion implantation of metals in the high concentration range for preparing amorphous layers (>= 10 at%, implantation doses > 10 16 ions/cm 2 ). Different models are described concerning formation of amorphous phases of metals by ion implantation and experimental results are given. The study of amorphous phases has been carried out by the aid of Rutherford backscattering combined with the channeling technique and using transmission electron microscopy. The structure of amorphous metals prepared by ion implantation has been discussed. It was concluded that amorphous metal-metalloid compounds can be described by a dense-random-packing structure with a great portion of metal atoms. Ion implantation has been compared with other techniques for preparing amorphous metals and the adventages have been outlined

  12. Ion implantation: an annotated bibliography

    International Nuclear Information System (INIS)

    Ting, R.N.; Subramanyam, K.

    1975-10-01

    Ion implantation is a technique for introducing controlled amounts of dopants into target substrates, and has been successfully used for the manufacture of silicon semiconductor devices. Ion implantation is superior to other methods of doping such as thermal diffusion and epitaxy, in view of its advantages such as high degree of control, flexibility, and amenability to automation. This annotated bibliography of 416 references consists of journal articles, books, and conference papers in English and foreign languages published during 1973-74, on all aspects of ion implantation including range distribution and concentration profile, channeling, radiation damage and annealing, compound semiconductors, structural and electrical characterization, applications, equipment and ion sources. Earlier bibliographies on ion implantation, and national and international conferences in which papers on ion implantation were presented have also been listed separately

  13. [Sinus floor elevation and augmentation. Evidence-based analysis of prognosis and risk factors].

    Science.gov (United States)

    Strietzel, F P

    2004-03-01

    It was the aim of this investigation to analyze evidence of prognosis, predictors, and risk factors concerning sinus floor elevation and augmentation (SFEA). A MEDLINE search was performed to analyze the literature published between 1990 and 2002, limited to keywords ("sinus floor elevation and dental implants", "complications", "success"), study type (randomized as well as clinical prospective studies, retrospective studies, reviews), and language (German or English). Of 229 publications identified, 72 met the inclusion criteria (22 prospective and 47 retrospective studies, 3 reviews). Considering the augmentation material [autogenous bone (AB), bone substitution materials (BSM), and combinations of AB and BSM], the frequency of implant loss was not significantly different (AB 8%, BSM 9%, AB + BSM 5%, p>0.09) after an observation period of 2-4 years. The average duration of the healing period was 6 months (AB) and 8 months (BSM) with simultaneous SFEA and implantation and 6-7 months (AB and BSM) for the staged approach after an average healing period of 6 months for the augmentation materials. Frequency of implant loss was not different between simultaneous and staged approaches (7-8%). Postoperative sinusitis occurred in 3-8% of the cases. Smoking, positive sinusitis history, obstructive pathoses of the nose and ostium, allergic rhino-pathoses, use of short implants (bruxism, and uncontrolled early loading of implants were identified as predictors for complications. Presupposing proper consideration of indications, SFEA should be considered as an evidence-based and clinically established method for implant prosthetic rehabilitation of the atrophic posterior maxilla with an overall cumulative survival rate of 90% within an average observation period of 4 years.

  14. Characterisation of Physical Frailty and Associated Physical and Functional Impairments in Mild Cognitive Impairment

    Directory of Open Access Journals (Sweden)

    Ma Shwe Zin Nyunt

    2017-12-01

    Full Text Available ObjectiveTo characterize the physical frailty phenotype and its associated physical and functional impairments in mild cognitive impairment (MCI.MethodParticipants with MCI (N = 119, normal low cognition (NLC, N = 138, and normal high cognition (NHC, N = 1,681 in the Singapore Longitudinal Ageing Studies (SLAS-2 were compared on the prevalence of physical frailty, low lean body mass, weakness, slow gait, exhaustion and low physical activity, and POMA balance and gait impairment and fall risk.ResultsThere were significantly higher prevalence of frailty in MCI (18.5%, than in NLC (8.0% and NHC (3.9%, and pre-frailty in MCI (54.6%, NLC (52.9% than in NHC (48.0%. Age, sex, and ethnicity-adjusted OR (95% CI of association with MCI (versus NHC for frailty were 4.65 (2.40–9.04 and for pre-frailty, 1.67 (1.07–2.61. Similar significantly elevated prevalence and adjusted ORs of association with MCI were observed for frailty-associated physical and functional impairments. Further adjustment for education, marital status, living status, comorbidities, and GDS significantly reduced the OR estimates. However, the OR estimates remained elevated for frailty: 3.86 (1.83–8.17, low body mass: 1.70 (1.08–2.67, slow gait: 1.84 (1.17–2.89, impaired gait: 4.17 (1.98–8.81, and elevated fall risk 3.42 (1.22–9.53.ConclusionTwo-thirds of MCI were physically frail or pre-frail, most uniquely due to low lean muscle mass, slow gait speed, or balance and gait impairment. The close associations of frailty and physical and functional impairment with MCI have important implications for improving diagnostic acuity of MCI and targetting interventions among cognitively frail individuals to prevent dementia and disability.

  15. Diet-induced obesity impairs endometrial stromal cell decidualization: a potential role for impaired autophagy.

    Science.gov (United States)

    Rhee, Julie S; Saben, Jessica L; Mayer, Allyson L; Schulte, Maureen B; Asghar, Zeenat; Stephens, Claire; Chi, Maggie M-Y; Moley, Kelle H

    2016-06-01

    What effect does diet-induced obesity have on endometrial stromal cell (ESC) decidualization? Diet-induced obesity impairs ESC decidualization. Decidualization is important for successful implantation and subsequent health of the pregnancy. Compared with normal-weight women, obese women have lower pregnancy rates (both spontaneous and by assisted reproductive technology), higher rates of early pregnancy loss and poorer oocyte quality. Beginning at 6 weeks of age, female C57Bl/6J mice were fed either a high-fat/high-sugar diet (HF/HS; 58% Fat Energy/Sucrose) or a diet of standard mouse chow (CON; 13% Fat) for 12 weeks. At this point, metabolic parameters were measured. Some of the mice (n = 9 HF/HS and 9 CON) were mated with reproductively competent males, and implantation sites were assessed. Other mice (n = 11 HF/HS and 10 CON) were mated with vasectomized males, and artificial decidualization was induced. For in vitro human studies of primary ESCs, endometrial tissue was obtained via biopsy from normo-ovulatory patients without history of infertility (obese = BMI > 30 kg/m(2), n = 11 and lean = BMI treatment with cAMP and medroxyprogesterone. The level of expression of decidualization markers was assessed by RT-qPCR (mRNA) and western blotting (protein). ATP content of ESCs was measured, and levels of autophagy were assessed by western blotting of the autophagy regulators acetyl coa carboxylase (ACC) and ULK1 (Ser 317). Autophagic flux was measured by western blot of the marker LC3b-II. Mice exposed to an HF/HS diet became obese and metabolically impaired. HF/HS-exposed mice mated to reproductively competent males had smaller implantation sites in early pregnancy (P obese women than in those of normal-weight women (Ptreatment abrogated this increase. Many aspects of obesity and metabolic impairment could contribute to the decidualization defects observed in the HF/HS-exposed mice. Although our findings suggest that both autophagy and decidualization are impaired

  16. Tribological properties of nitrogen implanted and boron implanted steels

    International Nuclear Information System (INIS)

    Kern, K.T.

    1996-01-01

    Samples of a steel with high chrome content was implanted separately with 75 keV nitrogen ions and with 75 keV boron ions. Implanted doses of each ion species were 2-, 4-, and 8 x 10 17 /cm 2 . Retained doses were measured using resonant non-Rutherford Backscattering Spectrometry. Tribological properties were determined using a pin-on-disk test with a 6-mm diameter ruby pin with a velocity of 0.94 m/min. Testing was done at 10% humidity with a load of 377 g. Wear rate and coefficient of friction were determined from these tests. While reduction in the wear rate for nitrogen implanted materials was observed, greater reduction (more than an order of magnitude) was observed for boron implanted materials. In addition, reduction in the coefficient of friction for high-dose boron implanted materials was observed. Nano-indentation revealed a hardened layer near the surface of the material. Results from grazing incidence x-ray diffraction suggest the formation of Fe 2 N and Fe 3 N in the nitrogen implanted materials and Fe 3 B in the boron implanted materials. Results from transmission electron microscopy will be presented

  17. Cochlear implantation in late-implanted adults with prelingual deafness.

    Science.gov (United States)

    Most, Tova; Shrem, Hadas; Duvdevani, Ilana

    2010-01-01

    The purpose of this study was to examine the effect of cochlear implantation (CI) on prelingually deafened participants who were implanted as adults. The effect of the CI was examined with regard to the following variables: communication, family, social skills, education, and work satisfaction with one's life, loneliness, and self-esteem. Thirty-eight adults participated. Four self-report questionnaires were used at 2 points in time: before and after CI. The research findings show significant differences in the reports of most variables before and after implantation. The participants felt better with regard to communication, social skills, education, and work and satisfaction with one's life after implantation in comparison to their feelings before implantation. Furthermore, they felt less lonely after implantation. However, there were no significant differences before and after implantation regarding their feelings within the family and regarding their self-esteem. The results demonstrated the need to evaluate the benefits resulting from the CI not only with traditional clinical measures but with additional measures as well. Furthermore, they demonstrated the benefit of the CI on the positive psychosociological implications of prelingually deafened adults. Copyright © 2010 Elsevier Inc. All rights reserved.

  18. Application of ion implantation in metals and alloys

    International Nuclear Information System (INIS)

    Dearnaley, G.

    1981-01-01

    Ion implantation first became established as a precise method of introducing dopant elements into semiconductors. It is now appreciated that there may be equally important applications in metallic tools or components with the purpose of improving their resistance to wear, fatigue or corrosion. Nitrogen ions implanted into steels pin dislocations and thereby harden the metal. Some metallic ions such as yttrium reduce the tendency for oxidative wear. There is a fairly good understanding of how both treatments can provide a long-lasting protection that extends to many times the original depth of implantation. Nitrogen implantation also improves the wear resistance of Co-cemented tungsten carbide and of hard chromium electroplated coatings. These treatments have wide application in press tools, molds, dies and other metal-forming tools as well as in a more limited variety of cutting tools. Some striking improvements can be achieved in the corrosion field, but there are economic and technical reasons for concluding that practical applications of ion implantation will be more restricted and specialized in this area. The most promising area is that in which mechanical stress and oxidation coexist. When a metallic species has to be introduced, a promising new development is to bombard a thin coating of the metal at an elevated temperature. Several powerful mechanisms of radiation-enhanced diffusion can bring about a complete intermixing. Examples of how this has been used to produce wear resistant surfaces in titanium are given. Finally, the equipment developed for the large scale application of the ion implantation process in the engineering field is described

  19. Vitamin E Phosphate Coating Stimulates Bone Deposition in Implant-related Infections in a Rat Model.

    Science.gov (United States)

    Lovati, Arianna B; Bottagisio, Marta; Maraldi, Susanna; Violatto, Martina B; Bortolin, Monica; De Vecchi, Elena; Bigini, Paolo; Drago, Lorenzo; Romanò, Carlo L

    2018-06-01

    Implant-related infections are associated with impaired bone healing and osseointegration. In vitro antiadhesive and antibacterial properties and in vivo antiinflammatory effects protecting against bone loss of various formulations of vitamin E have been demonstrated in animal models. However, to the best of our knowledge, no in vivo studies have demonstrated the synergistic activity of vitamin E in preventing bacterial adhesion to orthopaedic implants, thus supporting the bone-implant integration. The purpose of this study was to test whether a vitamin E phosphate coating on titanium implants may be able to reduce (1) the bacterial colonization of prosthetic implants and (2) bone resorption and osteomyelitis in a rat model of Staphylococcus aureus-induced implant-related infection. Twelve rats were bilaterally injected in the femurs with S aureus UAMS-1-Xen40 and implanted with uncoated or vitamin E phosphate-coated titanium Kirschner wires without local or systemic antibiotic prophylaxis. Eight rats represented the uninfected control group. A few hours after surgery, two control and three infected animals died as a result of unexpected complications. With the remaining rats, we assessed the presence of bacterial contamination with qualitative bioluminescence imaging and Gram-positive staining and with quantitative bacterial count. Bone changes in terms of resorption and osteomyelitis were quantitatively analyzed through micro-CT (bone mineral density) and semiquantitatively through histologic scoring systems. Six weeks after implantation, we found only a mild decrease in bacterial count in coated versus uncoated implants (Ti versus controls: mean difference [MD], -3.705; 95% confidence interval [CI], -4.416 to -2.994; p E-treated group compared with uncoated implants (knee joint: MD, -11.88; 95% CI, -16.100 to -7.664; p E-coated nails compared with the uncoated nails. These preliminary findings indicate that vitamin E phosphate implant coatings can exert a

  20. Iridium-192 implants in the treatment of tonsillar region malignancies

    International Nuclear Information System (INIS)

    Puthawala, A.A.; Syed, A.M.; Gates, T.C.

    1985-01-01

    A total of 127 patients with histologically proved diagnosis of carcinoma of the tonsillar region and soft palate were treated over the past ten years utilizing interstitial iridium-192 implants. Eighty patients were treated for primary tumors and 47 patients for either recurrent or persistent tumors after definitive irradiation and/or surgery. All patients with primary tumors were treated by a combination of external megavoltage irradiation and interstitial iridium-192 implants, whereas patients with recurrent tumors were treated by interstitial implants alone. In the primary group, 95% of patients with T1 and T2 lesions and 79% with T3 and T4 lesions achieved complete local tumor control. The three-year absolute disease-free survival rate was 72%. Seventy-five percent local tumor control was obtained in patients with recurrent disease, with two-year absolute disease-free survival of 42%. Treatment-related complications such as soft-tissue necrosis or osteoradionecrosis occurred in 6% of patients in the primary group and 23% in recurrent group. This treatment regimen offers an excellent locoregional control with no significant functional or esthetic impairment. Most patients with primary lesions who fail this regimen can be salvaged by surgery or reirradiation using interstitial implants

  1. Ethical considerations in resource allocation in a cochlear implant program.

    Science.gov (United States)

    Westerberg, Brian D; Pijl, Sipke; McDonald, Michael

    2008-04-01

    To review processes of resource allocation and the ethical considerations relevant to the fair allocation of a limited number of cochlear implants to increasing numbers of potential recipients. Review of relevant considerations. Tertiary referral hospital. Editorial discussion of the ethical issues of resource allocation. Heterogeneity of audiometric thresholds, self-reported disability of hearing loss, age of the potential cochlear implant recipient, cost-effectiveness, access to resources, compliance with follow-up, social support available to the recipient, social consequences of hearing impairment, and other recipient-related factors. In a publicly funded health care system, there will always be a need for decision-making processes for allocation of finite fiscal resources. All candidates for cochlear implantation deserve fair consideration. However, they are a heterogeneous group in terms of needs and expected outcomes consisting of traditional and marginal candidates, with a wide range of benefit from acoustic amplification. We argue that implant programs should thoughtfully prioritize treatment on the basis of need and potential benefit. We reject queuing on the basis of "first-come, first-served" or on the basis of perceived social worth.

  2. A Retrospective Analysis of Ruptured Breast Implants

    Directory of Open Access Journals (Sweden)

    Woo Yeol Baek

    2014-11-01

    Full Text Available BackgroundRupture is an important complication of breast implants. Before cohesive gel silicone implants, rupture rates of both saline and silicone breast implants were over 10%. Through an analysis of ruptured implants, we can determine the various factors related to ruptured implants.MethodsWe performed a retrospective review of 72 implants that were removed for implant rupture between 2005 and 2014 at a single institution. The following data were collected: type of implants (saline or silicone, duration of implantation, type of implant shell, degree of capsular contracture, associated symptoms, cause of rupture, diagnostic tools, and management.ResultsForty-five Saline implants and 27 silicone implants were used. Rupture was diagnosed at a mean of 5.6 and 12 years after insertion of saline and silicone implants, respectively. There was no association between shell type and risk of rupture. Spontaneous was the most common reason for the rupture. Rupture management was implant change (39 case, microfat graft (2 case, removal only (14 case, and follow-up loss (17 case.ConclusionsSaline implants have a shorter average duration of rupture, but diagnosis is easier and safer, leading to fewer complications. Previous-generation silicone implants required frequent follow-up observation, and it is recommended that they be changed to a cohesive gel implant before hidden rupture occurs.

  3. [Maintenance care for dental implant].

    Science.gov (United States)

    Kamoi, K

    1989-10-01

    Dental implant has tried at the early stage in 19th century recovering an oral function and esthetics. Technological revolutions in biochemical and new materials have developed on the remarkable change in the dental implants, nowadays we call the three generation therapy for dental implantology. There are many kinds of methods and techniques in dental implants, however a lot of troublesome complication on the process of surgical phase, construction of prothodontics and prognosis of maintenance care. In the proceedings of this symposium, I would like to propose you how to manage the maintenance care for various kind of dental implants through the methodology and case presentations. Tendenay and future for dental implants The current outlook of dental implant has increasing supply and demand not only dentists but also patients. According to Japanese Welfare Ministry's report in 1987, average missing teeth over sixty years old generations are approximately 42% in accordance with NIDR (U.S.A.) research. They are missed on ten over teeth in full 28th teeth dentitions owing to dental caries and periodontal diseases. Generally speaking, latent implant patients are occupied on the same possibility of needs for dental implants both Japan and U.S.A. Management of maintenance care The patients hardly recognized the importance of plaque control for the maintenance care in the intraoral condition after implantation. Dentists and dental staffs must be instruct patients for importance of plaque removal and control, because they already had forgotten the habit of teeth cleaning, especially in the edenturous conditions. 1) Concept of establishment in oral hygiene. Motivation and instruction for patients include very important factors in dental implants as well as in periodontal diseases. Patients who could not achieve on good oral hygiene levels obtained no good results in the long term observations. To establish good oral hygiene are how to control supra plaque surrounding tissues

  4. Vascular cognitive impairment

    Directory of Open Access Journals (Sweden)

    N.V. Vakhnina

    2014-01-01

    Full Text Available Vascular pathology of the brain is the second most common cause of cognitive impairment after Alzheimer's disease. The article describes the modern concepts of etiology, pathogenetic mechanisms, clinical features and approaches to diagnosis and therapy of vascular cognitive impairment (VCI. Cerebrovascular accident, chronic cerebral circulatory insufficiency and their combination, sometimes in combination with a concomitant neurodegenerative process, are shown to be the major types of brain lesions leading to VCI. The clinical presentation of VCI is characterized by the neuropsychological status dominated by impairment of the executive frontal functions (planning, control, attention in combination with focal neurological symptoms. The diagnosis is based on comparing of the revealed neuropsychological and neurological features with neuroimaging data. Neurometabolic, acetylcholinergic, glutamatergic, and other vasoactive drugs and non-pharmacological methods are widely used to treat VCI. 

  5. Lithium and Renal Impairment

    DEFF Research Database (Denmark)

    Nielsen, René Ernst; Kessing, Lars Vedel; Nolen, Willem A

    2018-01-01

    INTRODUCTION: Lithium is established as an effective treatment of mania, of depression in bipolar and unipolar disorder, and in maintenance treatment of these disorders. However, due to the necessity of monitoring and concerns about irreversible adverse effects, in particular renal impairment......, after long-term use, lithium might be underutilized. METHODS: This study reviewed 6 large observational studies addressing the risk of impaired renal function associated with lithium treatment and methodological issues impacting interpretation of results. RESULTS: An increased risk of renal impairment...... associated with lithium treatment is suggested. This increased risk may, at least partly, be a result of surveillance bias. Additionally, the earliest studies pointed toward an increased risk of end-stage renal disease associated with lithium treatment, whereas the later and methodologically most sound...

  6. Ion implantation apparatus

    International Nuclear Information System (INIS)

    Forneris, J.L.; Hicks, W.W.; Keller, J.H.; McKenna, C.M.; Siermarco, J.A.; Mueller, W.F.

    1981-01-01

    The invention relates to ion bombardment or implantation apparatus. It comprises an apparatus for bombarding a target with a beam of ions, including an arrangement for measuring the ion beam current and controlling the surface potential of the target. This comprises a Faraday cage formed, at least in part, by the target and by walls adjacent to, and electrically insulated from, the target and surrounding the beam. There is at least one electron source for supplying electrons to the interior of the Faraday cage and means within the cage for blocking direct rectilinear radiation from the source to the target. The target current is measured and combined with the wall currents to provide a measurement of the ion beam current. The quantity of electrons supplied to the interior of the cage can be varied to control the target current and thereby the target surface potential. (U.K.)

  7. Implantable biochemical fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Richter, G; Rao, J R

    1978-01-05

    Implantable biochemical fuel cells for the operation of heart pacemakers or artificial hearts convert oxidisable body substances such as glucose on the anode side and reduce the oxygen contained in body fluids at the cathode. The anode and cathode are separated by membranes which are impermeable to albumen and blood corpuscles in body fluids. A chemical shortcircuit cannot occur in practice if, according to the invention, one or more selective oxygen electrodes with carbon as catalyst are arranged so that the mixture which diffuses into the cell from body fluids during operation reaches the fuel cell electrode through the porous oxygen electrode. The membranes used must be permeable to water. Cellulose, polymerised polyvinyl alcohol or an ion exchanger with a buffering capacity between pH5 and 8 act as permeable materials.

  8. Implant materials modified by colloids

    Directory of Open Access Journals (Sweden)

    Zboromirska-Wnukiewicz Beata

    2016-03-01

    Full Text Available Recent advances in general medicine led to the development of biomaterials. Implant material should be characterized by a high biocompatibility to the tissue and appropriate functionality, i.e. to have high mechanical and electrical strength and be stable in an electrolyte environment – these are the most important properties of bioceramic materials. Considerations of biomaterials design embrace also electrical properties occurring on the implant-body fluid interface and consequently the electrokinetic potential, which can be altered by modifying the surface of the implant. In this work, the surface of the implants was modified to decrease the risk of infection by using metal colloids. Nanocolloids were obtained using different chemical and electrical methods. It was found that the colloids obtained by physical and electrical methods are more stable than colloids obtained by chemical route. In this work the surface of modified corundum implants was investigated. The implant modified by nanosilver, obtained by electrical method was selected. The in vivo research on animals was carried out. Clinical observations showed that the implants with modified surface could be applied to wounds caused by atherosclerotic skeleton, for curing the chronic and bacterial inflammations as well as for skeletal reconstruction surgery.

  9. Influence of Statins locally applied from orthopedic implants on osseous integration

    Directory of Open Access Journals (Sweden)

    Pauly Stephan

    2012-10-01

    Full Text Available Abstract Background Simvastatin increases the expression of bone morphogenetic protein 2 (BMP-2 in osteoblasts, therefore it is important to investigate the influence of statins on bone formation, fracture healing and implant integration. The aim of the present study was to investigate the effect of Simvastatin, locally applied from intramedullary coated and bioactive implants, on bone integration using biomechanical and histomorphometrical analyses. Methods Eighty rats received retrograde nailing of the femur with titanium implants: uncoated vs. polymer-only (poly(D,L-lactide vs. polymer plus drug coated (either Simvastatin low- or high dosed; “SIM low/ high”. Femurs were harvested after 56 days for radiographic and histomorphometric or biomechanical analysis (push-out. Results Radiographic analysis revealed no pathological findings for animals of the control and SIM low dose group. However, n=2/10 animals of the SIM high group showed osteolysis next to the implant without evidence of bacterial infection determined by microbiological analysis. Biomechanical results showed a significant decrease in fixation strength for SIM high coated implants vs. the control groups (uncoated and PDLLA. Histomorphometry revealed a significantly reduced total as well as direct bone/implant contact for SIM high- implants vs. controls (uncoated and PDLLA-groups. Total contact was reduced for SIM low vs. uncoated controls. Significantly reduced new bone formation was measured around SIM high coated implants vs. both control groups. Conclusions This animal study suggests impaired implant integration with local application of Simvastatin from intramedullary titanium implants after 8 weeks when compared to uncoated or carrier-only coated controls.

  10. Decrease of Staphylococcal adhesion on surgical stainless steel after Si ion implantation

    International Nuclear Information System (INIS)

    Braceras, Iñigo; Pacha-Olivenza, Miguel A.; Calzado-Martín, Alicia; Multigner, Marta; Vera, Carolina; Broncano, Luis Labajos-; Gallardo-Moreno, Amparo M.; González-Carrasco, José Luis; Vilaboa, Nuria

    2014-01-01

    Highlights: • Si ion implantation of AISI 316LVM medical grade alloy might reduce bacterial adhesion and colonization. • Si ion implantation does not impair the attachment, viability and matrix maturation of human mesenchymal stem cells. • Nano-topography and surface chemistry changes account for the Si ion implantation induced effects. - Abstract: 316LVM austenitic stainless steel is often the material of choice on temporal musculoskeletal implants and surgical tools as it combines good mechanical properties and acceptable corrosion resistance to the physiologic media, being additionally relatively inexpensive. This study has aimed at improving the resistance to bacterial colonization of this surgical stainless steel, without compromising its biocompatibility and resistance. To achieve this aim, the effect of Si ion implantation on 316LVM has been studied. First, the effect of the ion implantation parameters (50 keV; fluence: 2.5–5 × 10 16 ions/cm 2 ; angle of incidence: 45–90°) has been assessed in terms of depth profiling of chemical composition by XPS and nano-topography evaluation by AFM. The in vitro biocompatibility of the alloy has been evaluated with human mesenchymal stem cells. Finally, bacterial adhesion of Staphylococcus epidermidis and Staphylococcus aureus on these surfaces has been assessed. Reduction of bacterial adhesion on Si implanted 316LVM is dependent on the implantation conditions as well as the features of the bacterial strains, offering a promising implantable biomaterial in terms of biocompatibility, mechanical properties and resistance to bacterial colonization. The effects of surface composition and nano-topography on bacterial adhesion, directly related to ion implantation conditions, are also discussed

  11. Decrease of Staphylococcal adhesion on surgical stainless steel after Si ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Braceras, Iñigo, E-mail: inigo.braceras@tecnalia.com [Tecnalia, Mikeletegi Pasealekua 2, 20009 Donostia-San Sebastian (Spain); CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); Pacha-Olivenza, Miguel A. [CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); Universidad de Extremadura, Departamento de Física Aplicada, Facultad de Ciencias, Av. Elvas s/n, 06006 Badajoz (Spain); Calzado-Martín, Alicia [Hospital Universitario La Paz-IdiPAZ, Paseo de la Castellana 261, 28046 Madrid (Spain); CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); Multigner, Marta [Centro Nacional de Investigaciones Metalúrgicas, CENIM-CSIC, Avda Gregorio del Amo 8, 28040 Madrid (Spain); CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); Vera, Carolina [Tecnalia, Mikeletegi Pasealekua 2, 20009 Donostia-San Sebastian (Spain); CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); Broncano, Luis Labajos-; Gallardo-Moreno, Amparo M. [Universidad de Extremadura, Departamento de Física Aplicada, Facultad de Ciencias, Av. Elvas s/n, 06006 Badajoz (Spain); CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); González-Carrasco, José Luis [Centro Nacional de Investigaciones Metalúrgicas, CENIM-CSIC, Avda Gregorio del Amo 8, 28040 Madrid (Spain); CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); Vilaboa, Nuria [Hospital Universitario La Paz-IdiPAZ, Paseo de la Castellana 261, 28046 Madrid (Spain); CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); and others

    2014-08-15

    Highlights: • Si ion implantation of AISI 316LVM medical grade alloy might reduce bacterial adhesion and colonization. • Si ion implantation does not impair the attachment, viability and matrix maturation of human mesenchymal stem cells. • Nano-topography and surface chemistry changes account for the Si ion implantation induced effects. - Abstract: 316LVM austenitic stainless steel is often the material of choice on temporal musculoskeletal implants and surgical tools as it combines good mechanical properties and acceptable corrosion resistance to the physiologic media, being additionally relatively inexpensive. This study has aimed at improving the resistance to bacterial colonization of this surgical stainless steel, without compromising its biocompatibility and resistance. To achieve this aim, the effect of Si ion implantation on 316LVM has been studied. First, the effect of the ion implantation parameters (50 keV; fluence: 2.5–5 × 10{sup 16} ions/cm{sup 2}; angle of incidence: 45–90°) has been assessed in terms of depth profiling of chemical composition by XPS and nano-topography evaluation by AFM. The in vitro biocompatibility of the alloy has been evaluated with human mesenchymal stem cells. Finally, bacterial adhesion of Staphylococcus epidermidis and Staphylococcus aureus on these surfaces has been assessed. Reduction of bacterial adhesion on Si implanted 316LVM is dependent on the implantation conditions as well as the features of the bacterial strains, offering a promising implantable biomaterial in terms of biocompatibility, mechanical properties and resistance to bacterial colonization. The effects of surface composition and nano-topography on bacterial adhesion, directly related to ion implantation conditions, are also discussed.

  12. Social communication impairments: pragmatics.

    Science.gov (United States)

    Russell, Robert L

    2007-06-01

    Social communication or pragmatic impairments are characterized and illustrated as involving inappropriate or ineffective use of language and gesture in social contexts. Three clinical vignettes illustrate different pragmatic impairments and the wealth of diagnostic information that can be garnered from observation of a child's social communication behavior. Definitions of, and developmental milestones in, domains of pragmatic competence are provided. Several screening instruments are suggested for use in assessing pragmatic competence within the time-frame of a pediatric examination. Frequent comorbid psychiatric conditions are described and a sample of current neurobiologic research is briefly summarized.

  13. Capsule-Fixated Intraocular Lens Implantation in Small Pupil Cases.

    Science.gov (United States)

    Schojai, Merita; Schultz, Tim; Burkhard Dick, H

    2017-08-01

    To describe a new technique for implantation of capsule-fixated intraocular lenses (IOLs) (FEMTIS; Oculentis, Berlin, Germany) in patients with small pupils. In 4 eyes with small pupils, an anterior capsule-fixated IOL was implanted into the capsular bag after femtosecond laser treatment. The two large and two small flaps of the IOL were elevated to the front of the iris and the anterior capsule. Finally, the iris was flipped over the flaps to ensure a fixation of the capsule inside of the capsulotomy. In all cases, the implantation of anterior capsule-fixated IOLs was possible. No complications occurred during surgery or within the first months after surgery. With the described technique, capsulefixated IOLs can be implanted in eyes with small pupil easily and safely. This type of IOL has great potential to improve the refractive outcome by better prediction of the postoperative IOL position and eliminating IOL rotation after cataract surgery. [J Refract Surg. 2017;33(8):568-570.]. Copyright 2017, SLACK Incorporated.

  14. Implant Stability of Biological Hydroxyapatites Used in Dentistry

    Directory of Open Access Journals (Sweden)

    Maria Piedad Ramírez Fernández

    2017-06-01

    Full Text Available The aim of the present study was to monitor implant stability after sinus floor elevation with two biomaterials during the first six months of healing by resonance frequency analysis (RFA, and how physico-chemical properties affect the implant stability quotient (ISQ at the placement and healing sites. Bilateral maxillary sinus augmentation was performed in 10 patients in a split-mouth design using a bobine HA (BBM as a control and porcine HA (PBM. Six months after sinus lifting, 60 implants were placed in the posterior maxilla. The ISQ was recorded on the day of surgery from RFA at T1 (baseline, T2 (three months, and T3 (six months. Statistically significant differences were found in the ISQ values during the evaluation period. The ISQ (baseline was 63.8 ± 2.97 for BBM and 62.6 ± 2.11 for PBM. The ISQ (T2 was ~73.5 ± 4.21 and 67 ± 4.99, respectively. The ISQ (T3 was ~74.65 ± 2.93 and 72.9 ± 2.63, respectively. All of the used HAs provide osseointegration and statistical increases in the ISQ at baseline, T2 and T3 (follow-up, respectively. The BBM, sintered at high temperature with high crystallinity and low porosity, presented higher stability, which demonstrates that variations in the physico-chemical properties of a bone substitute material clearly influence implant stability.

  15. COCHLEAR IMPLANTATION PREVALENCE IN ELDERLY

    Directory of Open Access Journals (Sweden)

    A. V. Starokha

    2014-01-01

    Full Text Available Current paper describes an experience of cochlear implantation in elderly. Cochlear implantation has become a widely accepted intervention in the treatment of individuals with severe-to-profound sensorineural hearing loss. Cochlear implants are now accepted as a standard of care to optimize hearing and subsequent speech development in children and adults with deafness. But cochlear implantation affects not only hearing abilities, speech perception and speech production; it also has an outstanding impact on the social life, activities and self-esteem of each patient. The aim of this study was to evaluate the cochlear implantation efficacy in elderly with severe to profound sensorineural hearing loss. There were 5 patients under our observation. Surgery was performed according to traditional posterior tympanotomy and cochleostomy for cochlear implant electrode insertion for all observed patients. The study was conducted in two stages: before speech processor’s activation and 3 months later. Pure tone free field audiometry was performed to each patient to assess the efficiency of cochlear implantation in dynamics. The aim of the study was also to evaluate quality of life in elderly with severe to profound sensorineural hearing loss after unilateral cochlear implantation. Each patient underwent questioning with 36 Item Short Form Health Survey (SF-36. SF-36 is a set of generic, coherent, and easily administered quality-of-life measures. The SF-36 consists of eight scaled scores, which are the weighted sums of the questions in their section. Each scale is directly transformed into a 0-100 scale on the assumption that each question carries equal weight. The eight sections are: physical functioning; physical role functioning; emotional role functioning; vitality; emotional well-being; social role functioning; bodily pain; general health perceptions. Our results demonstrate that cochlear implantation in elderly consistently improved quality of life

  16. Number processing and arithmetic skills in children with cochlear implants

    Directory of Open Access Journals (Sweden)

    Silvia ePixner

    2014-12-01

    Full Text Available Though previous findings report that hearing impaired children exhibit impaired language and arithmetic skills, our current understanding of how hearing and the associated language impairments may influence the development of arithmetic skills is still limited. In the current study numerical/arithmetic performance of 45 children with a cochlea implant were compared to that of controls matched for hearing age, intelligence and sex. Our main results were twofold disclosing that children with CI show general as well as specific numerical/arithmetic impairments. On the one hand, we found an increased percentage of children with CI with an indication of dyscalculia symptoms, a general slowing in multiplication and subtraction as well as less accurate number line estimations. On the other hand, however, children with CI exhibited very circumscribed difficulties associated with place-value processing. Performance declined specifically when subtraction required a borrow procedure and number line estimation required the integration of units, tens, and hundreds instead of only units and tens. Thus, it seems that despite initially atypical language development, children with CI are able to acquire arithmetic skills in a qualitatively similar fashion as their normal hearing peers. Nonetheless, when demands on place-value understanding, which has only recently been proposed to be language mediated, hearing impaired children experience specific difficulties.

  17. Functional implications of corticospinal tract impairment on gait after spinal cord injury

    DEFF Research Database (Denmark)

    Barthélemy, Dorothy; Knudsen, Hanne; Willerslev-Olsen, Maria

    2013-01-01

    elevation with clinical physiotherapy tests.Setting:Cross-sectional study, laboratory and clinical settings.Methods:A total of 24 individuals with SCI (American Spinal Injury Association (ASIA) Impairment Scale D) were recruited. Maximum toe elevation during the swing phase of treadmill gait was measured...... indicate that maximum toe elevation, which is directly correlated with CST impairment, is functionally relevant as it also correlates with timed clinical tests, LEMS and sensory scores.Spinal Cord advance online publication, 13 August 2013; doi:10.1038/sc.2013.84....

  18. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection

    DEFF Research Database (Denmark)

    Starch-Jensen, Thomas; Christensen, Ann-Eva; Lorenzen, Henning

    2017-01-01

    OBJECTIVES: The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. MATERIAL AND METHODS: A MEDLINE (PubMed), Embase and Cochrane library search...... of suprastructures has never been compared within the same study. High implant survival rate was reported in all the included studies. Significantly more peri-implant marginal bone loss, higher probing depth score, bleeding score and gingival score was observed around implants with a scalloped implant-abutment...... loss around implants with a scalloped implant-abutment connection. CONCLUSIONS: A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must...

  19. Complex behavior of elevators in peak traffic

    Science.gov (United States)

    Nagatani, Takashi

    2003-08-01

    We study the dynamical behavior of elevators in the morning peak traffic. We present a stochastic model of the elevators to take into account the interactions between elevators through passengers. The dynamics of the elevators is expressed in terms of a coupled nonlinear map with noises. The number of passengers carried by an elevator and the time-headway between elevators exhibit the complex behavior with varying elevator trips. It is found that the behavior of elevators exhibits a deterministic chaos even if there are no noises. The chaotic motion depends on the loading parameter, the maximum capacity of an elevator, and the number of elevators. When the loading parameter is superior to the threshold, each elevator carries a full load of passengers throughout its trip. The dependence of the threshold (transition point) on the elevator capacity is clarified.

  20. Implantable cardioverter defibrillator implantation in children in The Netherlands

    NARCIS (Netherlands)

    Ten Harkel, ADJ; Blom, NA; Reimer, AG; Tukkie, R; Sreeram, N; Bink-Boelkens, MTE

    To evaluate the indications, underlying cardiac disorders, efficacy and complications involved with implantable cardioverter-defibrillators (ICDs) in paediatric patients in The Netherlands, the records of all patients aged 18 years or younger who underwent ICD placement were reviewed

  1. Implantable cardioverter defibrillator implantation in children in The Netherlands

    NARCIS (Netherlands)

    ten Harkel, A. Derk Jan; Blom, Nico A.; Reimer, Annette G.; Tukkie, Raymond; Sreeram, Narayanswami; Bink-Boelkens, Margreet T. E.

    2005-01-01

    To evaluate the indications, underlying cardiac disorders, efficacy and complications involved with implantable cardioverter-defibrillators (ICDs) in paediatric patients in The Netherlands, the records of all patients aged 18 years or younger who underwent ICD placement were reviewed

  2. Nitrogen implantation in steel with an impulsive ion implanter

    International Nuclear Information System (INIS)

    Feugeas, J.N.; Gonzalez, C.O.; Hermida, J.; Nieto, M.; Peyronel, M.F.; Sanchez, G.

    1990-01-01

    This work describes the results of steel implantation with nitrogen, with a pulsed accelerator which provides a continuous ion energy spectrum giving a uniform profile of nitrogen without changing its operative conditions. (Author)

  3. Ion implantation in semiconductor bodies

    International Nuclear Information System (INIS)

    Badawi, M.H.

    1984-01-01

    Ions are selectively implanted into layers of a semiconductor substrate of, for example, semi-insulating gallium arsenide via a photoresist implantation mask and a metallic layer of, for example, titanium disposed between the substrate surface and the photoresist mask. After implantation the mask and metallic layer are removed and the substrate heat treated for annealing purposes. The metallic layer acts as a buffer layer and prevents possible contamination of the substrate surface, by photoresist residues, at the annealing stage. Such contamination would adversely affect the electrical properties of the substrate surface, particularly gallium arsenide substrates. (author)

  4. Hardness of ion implanted ceramics

    International Nuclear Information System (INIS)

    Oliver, W.C.; McHargue, C.J.; Farlow, G.C.; White, C.W.

    1985-01-01

    It has been established that the wear behavior of ceramic materials can be modified through ion implantation. Studies have been done to characterize the effect of implantation on the structure and composition of ceramic surfaces. To understand how these changes affect the wear properties of the ceramic, other mechanical properties must be measured. To accomplish this, a commercially available ultra low load hardness tester has been used to characterize Al 2 O 3 with different implanted species and doses. The hardness of the base material is compared with the highly damaged crystalline state as well as the amorphous material

  5. Placement of single tooth implant in healed socket with immediate temporization: Clinical study

    Directory of Open Access Journals (Sweden)

    Jeevan Lata

    2012-01-01

    Full Text Available Introduction: Edentulous condition inadequately compensated for, by dentures, impair oral function and is accompanied by reduced self–confidence. In a continued effort to achieve these goals, implant dentistry was introduced. Immediate temporization is somehow a recent concept, which allows the maintenance of soft tissue contours, along with interdental alveolar contours. Aims and Obectives: Aims of the present study were to study the placement of implant in the post-extracted healed tooth socket of anterior maxilla and to evaluate the feasibility of early function on implants placed. Materials and Methods: In the present study, HI-TECH IMPLANTS TRX-OP one-piece immediate loading implant system with the built on abutment has been used.Immediate temporisation has been done and results have been evaluated in terms of stability, gingival health, esthetics, marginal bone loss, patient′s psychological attitude, and satisfaction.
Results: Out of eight implants, 6 successfully healed whereas 2 implants suffered failure
Conclusion: Overall conclusion drawn from the study is, immediate temporization is a successful method providing psychological, financial and emotional benefits to the patient.

  6. Correction of Malpositioned Implants through Periodontal Surgery and Prosthetic Rehabilitation Using Angled Abutment

    Directory of Open Access Journals (Sweden)

    Érica Dorigatti de Avila

    2014-01-01

    Full Text Available When dental implants are malpositioned in relation to the adjacent teeth and alveolar bone or in an excessive buccal or lingual position, the final prosthesis rehabilitation impairs the peri-implant health of the gingival tissues and the aesthetics of the patient. Thus, the purpose of this case was to report and discuss a multidisciplinary protocol for the treatment of a compromised maxillary tooth in a patient with an abscess in his right central incisor due to an excessive buccal implant position. The patient presented with an implant-supported provisional restoration on his right maxillary central incisor and a traumatic injury in his left central incisor. The treatment protocol consisted in (i abutment substitution to compensate the incorrect angulation of the implant, (ii clinical crown lengthening, (iii atraumatic extraction of the left central incisor, and (iv immediate implant placement. Finally, (v a custom abutment was fabricated to obtain a harmonious gingival contour around the prosthetic crown. In conclusion, when implants are incorrectly positioned in relation to the adjacent teeth, associated with soft-tissue defects, the challenge to create a harmonious mucogingival contours may be achieved with an interdisciplinary approach and with the placement of an appropriate custom abutment.

  7. The stereognostic ability of natural dentitions versus implant-supported fixed prostheses or overdentures.

    Science.gov (United States)

    Jacobs, R; Bou Serhal, C; van Steenberghe, D

    1997-06-01

    A stereognostic ability test was performed in 60 patients. Forty patients were rehabilitated by means of osseointegrated implants. One group consisted of 20 patients with fixed prostheses on implants in both the upper and lower jaws. The other 20 patients had a maxillary denture while in the mandible an overdenture was retained by means of two implants connected by a bar. They were compared to a group of 20 subjects (controls) with a non-restored natural dentition. For the stereognostic ability test, subjects had to recognise ten different test pieces by manipulating them with two antagonistic incisor teeth, avoiding any contact with other oral structures. Both response time and percentage accuracy of recognition were evaluated. The present findings indicated that subjects with an overdenture on implants did not score significantly different from those with an implant-supported fixed prosthesis. In contrast, subjects with teeth had a significantly better stereognostic ability. The percentage of correct responses was 52% for overdentures, 56% for fixed prostheses on implants and 75% for natural dentitions. From these results, it could be concluded that the stereognostic ability is impaired in subjects rehabilitated with osseointegrated implants by about one-third to one-quarter compared to subjects with natural teeth.

  8. An introduction to single implant abutments.

    LENUS (Irish Health Repository)

    Warreth, Abdulhadi

    2013-01-01

    This article is an introduction to single implant abutments and aims to provide basic information about abutments which are essential for all dental personnel who are involved in dental implantology. Clinical Relevance: This article provides a basic knowledge of implants and implant abutments which are of paramount importance, as replacement of missing teeth with oral implants has become a well-established clinical procedure.

  9. Cochlear implantation in a bilateral Mondini dysplasia.

    Science.gov (United States)

    Turrini, M; Orzan, E; Gabana, M; Genovese, E; Arslan, E; Fisch, U

    1997-01-01

    We report the speech perception progress and programming procedures of a case of congenital profound deafness and bilateral Mondini dysplasia implanted with a Nucleus 20 + 2 cochlear implant at the age of six. Unclear relations between electrodes array and cochlear partition made implant programming difficult and non-standard procedures were set. Cochlear implantation may give excellent rehabilitative results also in cochleae with malformation.

  10. Annealing Behavior of Al-Implantation-Induced Disorder in 4H-SiC

    International Nuclear Information System (INIS)

    Zhang, Yanwen; Weber, William J.; Jiang, Weilin; Shutthanandan, V.; Thevuthasan, Suntharampillai; Janson, Martin; Hallen, Anders

    2004-01-01

    Single crystal 4H-SiC films were implanted at 150 K with 1.1 MeV Al 2 2+ and subsequently annealed at elevated temperatures. Rutherford backscattering spectrometry (RBS) results indicate that the relative Si disorder at the damage peak recovers significantly as the annealing temperature increases. However, the residual Si disorder is more resistant to high-temperature annealing in the region of the implanted Al. The maximum concentration of Al profile measured by secondary ion mass spectroscopy (SIMS) is a factor of 1000 lower than the level of the residual Si disorder at the same region. Analysis of these results indicates that the excess residual Si disorder around the implanted Al projected range cannot be accounted for by just the Al interstitials; instead, it appears that each implanted Al stabilizes or inhibits recovery for an equivalent of a few hundred Si interstitials under the current experimental conditions

  11. The alteration of oxidation and related properties of metals by ion implantation

    International Nuclear Information System (INIS)

    Dearnaley, G.

    1981-01-01

    A review is given of the various ways in which ion implanted additives can affect the thermal oxidation of metals, for example by blocking diffusion paths for ions, by catalytic effects or by altering the plasticity of the oxide. The versatility of the process has already proved useful in the study of oxidation mechanisms. Ways of achieving a long-lasting protection are discussed in relation to the dominant mechanisms of oxidation inhibition. In many practical applications at elevated temperatures oxidation and mechanical stresses co-exist. In steels the process of oxidative wear is important under conditions of poor lubrication and implanted metallic ions have been shown to be effective. In titanium alloys fatigue cracks probably initiate at dislocation sites at which oxidation proceeds most rapidly, and hence the same implanted species can improve both types of behaviour. Successful implantation treatments for fretting fatigue in titanium and a corrosion-erosion problem in steel are described. (orig.)

  12. High-temperature Au implantation into Ni-Be and Ni-Si alloys

    Science.gov (United States)

    James, M. R.; Lam, N. Q.; Rehn, L. E.; Baldo, P. M.; Funk, L.; Stubbins, J. F.

    1992-12-01

    Effects of implantation temperature and target composition on depth distribution of implanted species were investigated. Au+ ions were implanted at 300 keV into polycrystalline Ni-Be and Ni-Si alloys between 25 and 700C to a dose of 10(exp 16) cm(exp -2). Depth distributions of Au were analyzed with RBS using He+ at both 1.7 and 3.0 MeV, and those of the other alloying elements by SIMS. Theoretical modeling of compositional redistribution during implantation at elevated temperatures was also carried out with the aid of a comprehensive kinetic model. The analysis indicated that below approximately 250C, the primary controlling processes were preferential sputtering and displacement mixing, while between 250 and 600C radiation-induced segregation was dominant. Above 600C, thermal-diffusion effects were most important. Fitting of model calculations to experimental measurements provided values for various defect migration and formation parameters.

  13. Vessels for elevated temperature service

    International Nuclear Information System (INIS)

    O'Donnell, W.J.; Porowski, J.S.

    1983-01-01

    The subject is covered in chapters, entitled: introduction (background; elevated temperature concerns; design tools); design of pressure vessels for elevated temperature per ASME code; basic elevated temperature failure modes; allowable stresses and strains per ASME code (basic allowable stress limits; ASME code limits for bending; time-fraction summations; strain limits; buckling and instability; negligible creep and stress-rupture effects); combined membrane and bending stresses in creep regime; thermal stress cycles; bounding methods based on elastic core concept (bounds on accumulated strains; more accurate bounds; strain ranges; maximum stresses; strains at discontinuities); elastic follow-up; creep strain concentrations; time-dependent fatigue (combined creep rupture and fatigue damage; limits for inelastic design analyses; limits for elastic design analyses); flaw evaluation techniques; type 316 stainless steel; type 304 stainless steel; steel 2 1/4Cr1Mo; Inconel 718; Incolloy 800; Hastelloy X; detailed inelastic design analyses. (U.K.)

  14. Implant retention systems for implant-retained overdentures.

    Science.gov (United States)

    Laverty, D P; Green, D; Marrison, D; Addy, L; Thomas, M B M

    2017-03-10

    Implant retained overdentures are being increasingly utilised in both general and specialist practice to rehabilitate patients with missing teeth, particularly those that are edentate. This article aims to inform the reader of a variety of retention systems that are available to retain an implant overdenture and to understand how these systems work, their advantages and disadvantages and to outline some of the clinical and treatment planning considerations involved in selecting the most appropriate retention system for patients.

  15. Implant Materials Generate Different Peri-implant Inflammatory Factors

    OpenAIRE

    Olivares-Navarrete, Rene; Hyzy, Sharon L.; Slosar, Paul J.; Schneider, Jennifer M.; Schwartz, Zvi; Boyan, Barbara D.

    2015-01-01

    Study Design. An in vitro study examining factors produced by human mesenchymal stem cells on spine implant materials. Objective. The aim of this study was to examine whether the inflammatory microenvironment generated by cells on titanium-aluminum-vanadium (Ti-alloy, TiAlV) surfaces is affected by surface microtexture and whether it differs from that generated on poly-ether-ether-ketone (PEEK). Summary of Background Data. Histologically, implants fabricated from PEEK have a fibrous connectiv...

  16. Impact of implant size on cement filling in hip resurfacing arthroplasty.

    Science.gov (United States)

    de Haan, Roel; Buls, Nico; Scheerlinck, Thierry

    2014-01-01

    Larger proportions of cement within femoral resurfacing implants might result in thermal bone necrosis. We postulate that smaller components are filled with proportionally more cement, causing an elevated failure rate. A total of 19 femoral heads were fitted with polymeric replicas of ReCap (Biomet) resurfacing components fixed with low-viscosity cement. Two specimens were used for each even size between 40 and 56 mm and one for size 58 mm. All specimens were imaged with computed tomography, and the cement thickness and bone density were analyzed. The average cement mantle thickness was 2.63 mm and was not correlated with the implant size. However, specimen with low bone density had thicker cement mantles regardless of size. The average filling index was 36.65% and was correlated to both implant size and bone density. Smaller implants and specimens with lower bone density contained proportionally more cement than larger implants. According to a linear regression model, bone density but not implant size influenced cement thickness. However, both implant size and bone density had a significant impact on the filling index. Large proportions of cement within the resurfacing head have the potential to generate thermal bone necrosis and implant failure. When considering hip resurfacing in patients with a small femoral head and/or osteoporotic bone, extra care should be taken to avoid thermal bone necrosis, and alternative cementing techniques or even cementless implants should be considered. This study should help delimiting the indications for hip resurfacing and to choose an optimal cementing technique taking implant size into account.

  17. Troponin elevation in subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Ioannis N. Mavridis

    2015-03-01

    Full Text Available Troponin (tr elevation in aneurysmal subarachnoid hemorrhage (SAH patients is often difficult to be appropriately assessed by clinicians, causing even disagreements regarding its management between neurosurgeons and cardiologists. The purpose of this article was to review the literature regarding the clinical interpretation of tr elevation in SAH. We searched for articles in PubMed using the key words: “troponin elevation” and “subarachnoid hemorrhage”. All of them, as well as relative neurosurgical books, were used for this review. Some type of cardiovascular abnormality develops in most SAH patients. Neurogenic stunned myocardium is a frequent SAH complication, due to catecholamine surge which induces cardiac injury, as evidenced by increased serum tr levels, electrocardiographic (ECG changes and cardiac wall motion abnormalities. Tr elevation, usually modest, is an early and specific marker for cardiac involvement after SAH and its levels peak about two days after SAH. Cardiac tr elevation predictors include poor clinical grade, intraventricular hemorrhage, loss of consciousness at ictus, global cerebral edema, female sex, large body surface area, lower systolic blood pressure, higher heart rate and prolonged Q-Tc interval. Elevated tr levels are associated with disability and death (especially tr >1 μg/L, worse neurological grade, systolic and diastolic cardiac dysfunction, pulmonary congestion, longer intensive care unit stay and incidence of vasospasm. Tr elevation is a common finding in SAH patients and constitutes a rightful cause of worry about the patients' cardiac function and prognosis. It should be therefore early detected, carefully monitored and appropriately managed by clinicians.

  18. Impaired receptivity and decidualization in DHEA-induced PCOS mice.

    Science.gov (United States)

    Li, Shu-Yun; Song, Zhuo; Song, Min-Jie; Qin, Jia-Wen; Zhao, Meng-Long; Yang, Zeng-Ming

    2016-12-07

    Polycystic ovary syndrome (PCOS), a complex endocrine disorder, is a leading cause of female infertility. An obvious reason for infertility in PCOS women is anovulation. However, success rate with high quality embryos selected by assisted reproduction techniques in PCOS patients still remain low with a high rate of early clinical pregnancy loss, suggesting a problem in uterine receptivity. Using a dehydroepiandrosterone-induced mouse model of PCOS, some potential causes of decreased fertility in PCOS patients were explored. In our study, ovulation problem also causes sterility in PCOS mice. After blastocysts from normal mice are transferred into uterine lumen of pseudopregnant PCOS mice, the rate of embryo implantation was reduced. In PCOS mouse uteri, the implantation-related genes are also dysregulated. Additionally, artificial decidualization is severely impaired in PCOS mice. The serum estrogen level is significantly higher in PCOS mice than vehicle control. The high level of estrogen and potentially impaired LIF-STAT3 pathway may lead to embryo implantation failure in PCOS mice. Although there are many studies about effects of PCOS on endometrium, both embryo transfer and artificial decidualization are applied to exclude the effects from ovulation and embryos in our study.

  19. Historie i spillefilm - for elever

    DEFF Research Database (Denmark)

    Tønnesen, Lone Guldbrandt

    2016-01-01

    MOOC om historiebrug i spillefilm, hvor elever kan lære om, hvordan spillefilm bruger fortiden, og om hvordan vores opfattelse af historien både sætter sig spor i filmene og bliver påvirket af dem.......MOOC om historiebrug i spillefilm, hvor elever kan lære om, hvordan spillefilm bruger fortiden, og om hvordan vores opfattelse af historien både sætter sig spor i filmene og bliver påvirket af dem....

  20. Tether Elevator Crawler Systems (TECS)

    Science.gov (United States)

    Swenson, Frank R.

    1987-01-01

    One of the needs of the experimenters on the space station is access to steady and controlled-variation microgravity environments. A method of providing these environments is to place the experiment on a tether attached to the space station. This provides a high degree of isolation from structural oscillations and vibrations. Crawlers can move these experiments along the tethers to preferred locations, much like an elevator. This report describes the motion control laws developed for these crawlers and the testing of laboratory models of these tether elevator crawlers.

  1. Medications and impaired driving.

    Science.gov (United States)

    Hetland, Amanda; Carr, David B

    2014-04-01

    To describe the association of specific medication classes with driving outcomes and provide clinical recommendations. The MEDLINE and EMBASE databases were searched for articles published from January 1973 to June 2013 on classes of medications associated with driving impairment. The search included outcome terms such as automobile driving, motor vehicle crash, driving simulator, and road tests. Only English-language articles that contained findings from observational or interventional designs with ≥ 10 participants were included in this review. Cross-sectional studies, case series, and case reports were excluded. Driving is an important task and activity for the majority of adults. Some commonly prescribed medications have been associated with driving impairment measured by road performance, driving simulation, and/or motor vehicle crashes. This review of 30 studies identified findings with barbiturates, benzodiazepines, hypnotics, antidepressants, opioid and nonsteroidal analgesics, anticonvulsants, antipsychotics, antiparkinsonian agents, skeletal muscle relaxants, antihistamines, anticholinergic medications, and hypoglycemic agents. Additional studies of medication impact on sedation, sleep latency, and psychomotor function, as well as the role of alcohol, are also discussed. Psychotropic agents and those with central nervous system side effects were associated with measures of impaired driving performance. It is difficult to determine if such associations are actually a result of medication use or the medical diagnosis itself. Regardless, clinicians should be aware of the increased risk of impaired driving with specific classes of medications, educate their patients, and/or consider safer alternatives.

  2. Structure of ion-implanted ceramics

    International Nuclear Information System (INIS)

    Naramoto, Hiroshi

    1983-01-01

    The variation of structure of LiF, MgO, Al 2 O 3 and TiO 2 accompanying annealing after ion implantation is explained. The analysis of structure is usually made by the perturbed gamma ray angular correlation, the internal electron Moessbauer method, or the ion scattering method. The results of analyses are discussed for alkali ion implantation, Fe-ion implantation, In-ion implantation, Au-ion implantation, Pt-ion implantation, Pb-ion implantation and transition metal ion implantation. The coupling of the implanted elements with lattice defects and matrix elements, and the compatibility between deposited elements and matrix crystal lattice were studied. The variation of physical properties due to ion implantation such as phase transition, volume change, the control of single crystal region, and the variation of hardness near surface were investigated, and the examples are presented. (Kato, T.)

  3. Can cochlear implantation improve neurocognition in the aging population?

    Directory of Open Access Journals (Sweden)

    Völter C

    2018-04-01

    Full Text Available Christiane Völter,1 Lisa Götze,1 Stefan Dazert,1 Michael Falkenstein,2,3 Jan Peter Thomas1 1Department of Otorhinolaryngology, Head and Neck Surgery, Ruhr University Bochum, St. Elisabeth-Hospital, Bochum, Germany; 2Institute for Work, Learning and Ageing (ALA, Bochum, Germany; 3Leibniz Research Centre for Working Environment and Human Factors, Dortmund, Germany Introduction: The relationship between cognition and the ability to hear is well known. Due to changes in demographics, the number of people with sensorineural hearing loss and cognitive impairment is increasing. The aim of this study was to identify the impact of hearing rehabilitation via cochlear implantation on cognitive decline among the aging population. Patients and methods: This prospective study included 60 subjects aged between 50 and 84 years (mean 65.8 years, SD=8.9 with a severe to profound bilateral hearing impairment. A computer-based evaluation of short- and long-term memory, processing speed, attention, working memory and inhibition was performed prior to surgery as well as 6 and 12 months after cochlear implantation. Additionally, speech perception at 65 and 80 dB (Freiburger monosyllabic speech test as well as disease-related (Nijmegen Cochlear Implant Questionnaire and general (WHOQOL-OLD quality of life were assessed. Results: Six months postimplantation, speech perception, quality of life and also neurocognitive abilities significantly increased. The most remarkable improvement after 6 months was detected in executive functions such as attention (p<0.001, inhibition (p=0.025 and working memory (n-back: p=0.002; operation span task: p=0.008, followed by delayed recall (p=0.03. In contrast, long-term memory showed a significant change of performance only after 12 months (p=0.021. After 6 months, most cognitive domains remained stable, except working memory assessed by the operation span task, which significantly improved between 6 and 12 months (p<0.001. No

  4. A novel intravitreal fluocinolone acetonide implant (Iluvien® in the treatment of patients with chronic diabetic macular edema that is insufficiently responsive to other medical treatment options: a case series

    Directory of Open Access Journals (Sweden)

    Schmit-Eilenberger VK

    2015-05-01

    Full Text Available Vera K Schmit-Eilenberger Augenklinik Städtisches Klinikum, Karlsruhe, Baden-Württemberg, Germany Background: Iluvien® is a novel, nonbiodegradable, sustained-release drug delivery system (0.2 µg/d fluocinolone acetonide [FAc] indicated in Europe for the treatment of vision impairment associated with chronic diabetic macular edema (DME, considered insufficiently responsive to available therapies.Objective: To evaluate the safety and efficacy of 190-µg FAc implant in patients with chronic DME refractory to other medical treatment options in a clinical setting. Methods: Retrospective registry data were collected by using standard case report forms (CRFs. Prior to intravitreal injection of the FAc implant, all patients were treated either with a vascular endothelial growth factor (VEGF antagonist and/or a steroid (triamcinolone, dexamethasone implant. Patients were excluded from receiving FAc if they had a known history of elevated intraocular pressure (IOP following corticosteroid therapy, glaucoma, ocular hypertension, or any contraindications cited in the summary of product characteristics. Best-corrected visual acuity (BCVA was the main study parameter. Central fovea thickness (CFT and IOP were measured concurrently. These parameters were recorded prior to and after the injection of the 190-µg FAc implant (between 1 week and 9 months. Injections were performed between May 2013 and March 2014.Results: Fifteen eyes from ten patients were treated. Thirteen eyes (nine patients were pseudophakic, and seven eyes (five patients were vitrectomized prior to receiving therapy. BCVA improved in eleven eyes (73.3%, remained unchanged in two eyes (13.3%, and decreased slightly in two eyes (13.3% at the last follow-up visit versus baseline levels. IOP increased in two patients and was controlled using fixed-combination of IOP-lowering eyedrops or sectorial cyclocryotherapy (n=1.Conclusion: The 190-µg FAc implant was efficacious and showed a favorable

  5. Do breast implants adversely affect prognosis among those subsequently diagnosed with breast cancer? Findings from an extended follow-up of a Canadian cohort.

    Science.gov (United States)

    Lavigne, Eric; Holowaty, Eric J; Pan, Sai Yi; Xie, Lin; Villeneuve, Paul J; Morrison, Howard; Brisson, Jacques

    2012-10-01

    Cosmetic breast implants may impair the ability to detect breast cancers. The aims of this study were to examine whether implants and implant characteristics are associated with more advanced breast tumors at diagnosis and poorer survival. Study population includes all invasive breast cancer cases diagnosed during follow-up of the large Canadian Breast Implant Cohort. A total of 409 women with cosmetic breast implants and 444 women with other cosmetic surgery were diagnosed with breast cancer. These women were compared for stage at diagnosis using multinomial logistic regression models. Cox proportional hazards regression models were used for breast cancer-specific mortality analyses. Comparisons were also conducted according to implant characteristics. Compared with women with other cosmetic surgery, those with cosmetic breast implants had at later stage breast cancer diagnosis (OR of having stage III/IV vs. stage I at diagnosis: 3.04, 95% confidence interval (CI): 1.81-5.10; P breast cancer-specific mortality rate for women with breast implants relative to surgical controls was observed (HR = 1.32, 95% CI: 0.94-1.83, P = 0.11). No statistically significant differences in stage and breast cancer mortality were observed according to implant characteristics. At diagnosis, breast cancers tended to be at more advanced stages among women with cosmetic breast implants. Breast cancer-specific survival was lower in these women although the reduction did not reach statistical significance. Further investigations of the effect of breast implants on breast cancer prognosis are warranted. 2012 AACR

  6. Time-dependent cytokine expression in bone of experimental animals after hydroxyapatite (Hap) implantation

    International Nuclear Information System (INIS)

    Pilmane, M; Salms, G; Salma, I; Skagers, A; Locs, J; Loca, D; Berzina-Cimdina, L

    2011-01-01

    Proinflammatory cytokines mediate bone loss around the implants in patients with peri-implant disease. However, there is no complete data about the expression of cytokines into the bone around the implants. The aim of this work was to investigate the distribution and appearance of inflammatory cytokines and anti-inflammatory proteins in the bone of jaw of experimental rabbits in different time periods after HAp implantation. Material was obtained from 8 rabbits in lower jaw 6 and 8 months after HAp implants were placed. Tissues were processed for immunohistochemical detection of tumor necrosis factor alfa (TNFα), Interleukin 1, 6, 8, 10 (IL-1, IL-6, IL-8, IL-10) and defensin 2. Results demonstrated practically unchanged expression of IL-6 and IL-10 between both - experimental and control side 6 months after implantation, while IL-1 and IL-8 notably increased in control side. IL-1 and IL-10 expression did not change in either the experimental side nor the controle side after 8 months HAP implantation, but IL-6 and IL-8 demonstrated a decrease in the control sites. Only IL-8 was elevated with time in experimental sites, while IL-10 showed individual variations in 2 cases.

  7. Amorphous Ge quantum dots embedded in SiO2 formed by low energy ion implantation

    International Nuclear Information System (INIS)

    Zhao, J. P.; Huang, D. X.; Jacobson, A. J.; Chen, Z. Y.; Makarenkov, B.; Chu, W. K.; Bahrim, B.; Rabalais, J. W.

    2008-01-01

    Under ultrahigh vacuum conditions, extremely small Ge nanodots embedded in SiO 2 , i.e., Ge-SiO 2 quantum dot composites, have been formed by ion implantation of 74 Ge + isotope into (0001) Z-cut quartz at a low kinetic energy of 9 keV using varying implantation temperatures. Transmission electron microscopy (TEM) images and micro-Raman scattering show that amorphous Ge nanodots are formed at all temperatures. The formation of amorphous Ge nanodots is different from reported crystalline Ge nanodot formation by high energy ion implantation followed by a necessary high temperature annealing process. At room temperature, a confined spatial distribution of the amorphous Ge nanodots can be obtained. Ge inward diffusion was found to be significantly enhanced by a synergetic effect of high implantation temperature and preferential sputtering of surface oxygen, which induced a much wider and deeper Ge nanodot distribution at elevated implantation temperature. The bimodal size distribution that is often observed in high energy implantation was not observed in the present study. Cross-sectional TEM observation and the depth profile of Ge atoms in SiO 2 obtained from x-ray photoelectron spectra revealed a critical Ge concentration for observable amorphous nanodot formation. The mechanism of formation of amorphous Ge nanodots and the change in spatial distribution with implantation temperature are discussed

  8. Time-dependent cytokine expression in bone of experimental animals after hydroxyapatite (Hap) implantation

    Energy Technology Data Exchange (ETDEWEB)

    Pilmane, M [Riga Stradins University, Institute of Anatomy and Anthropology, Dzirciema 16, LV-1007, Riga (Latvia); Salms, G; Salma, I; Skagers, A [Riga Stradins University, Department of Oral and Maxillofacial Surgery, Dzirciema 20. LV-1007, Riga (Latvia); Locs, J; Loca, D; Berzina-Cimdina, L, E-mail: pilmane@latnet.lv [Riga Technical University, Riga Biomaterials innovation and development centre, Pulka 3/3, LV-1007, Riga (Latvia)

    2011-06-23

    Proinflammatory cytokines mediate bone loss around the implants in patients with peri-implant disease. However, there is no complete data about the expression of cytokines into the bone around the implants. The aim of this work was to investigate the distribution and appearance of inflammatory cytokines and anti-inflammatory proteins in the bone of jaw of experimental rabbits in different time periods after HAp implantation. Material was obtained from 8 rabbits in lower jaw 6 and 8 months after HAp implants were placed. Tissues were processed for immunohistochemical detection of tumor necrosis factor alfa (TNF{alpha}), Interleukin 1, 6, 8, 10 (IL-1, IL-6, IL-8, IL-10) and defensin 2. Results demonstrated practically unchanged expression of IL-6 and IL-10 between both - experimental and control side 6 months after implantation, while IL-1 and IL-8 notably increased in control side. IL-1 and IL-10 expression did not change in either the experimental side nor the controle side after 8 months HAP implantation, but IL-6 and IL-8 demonstrated a decrease in the control sites. Only IL-8 was elevated with time in experimental sites, while IL-10 showed individual variations in 2 cases.

  9. Surface microhardening by ion implantation

    International Nuclear Information System (INIS)

    Singh, Amarjit

    1986-01-01

    The paper discusses the process and the underlying mechanism of surface microhardening by implanting suitable energetic ions in materials like 4145 steel, 304 stainless steel, aluminium and its 2024-T351 alloy. It has been observed that boron and nitrogen implantation in materials like 4145 steel and 304 stainless steel can produce a significant increase in surface hardness. Moreover the increase can be further enhanced with suitable overlay coatings such as aluminium (Al), Titanium (Ti) and carbon (C). The surface hardening due to implantation is attributed to precipitation hardening or the formation of stable/metastable phase or both. The effect of lithium implantation in aluminium and its alloy on microhardness with increasing ion dose and ion beam energy is also discussed. (author)

  10. Implanted-tritium permeation experiments

    International Nuclear Information System (INIS)

    Longhurst, G.R.; Holland, D.F.; Casper, L.A.; Hsu, P.Y.; Miller, L.G.; Schmunk, R.E.; Watts, K.D.; Wilson, C.J.; Kershner, C.J.; Rogers, M.L.

    1982-04-01

    In fusion reactors, charge exchange neutral atoms of tritium coming from the plasma will be implanted into the first wall and other interior structures. EG and G Idaho is conducting two experiments to determine the magnitude of permeation into the coolant streams and the retention of tritium in those structures. One experiment uses an ion gun to implant deuterium. The ion gun will permit measurements to be made for a variety of implantation energies and fluxes. The second experiment utilizes a fission reactor to generate a tritium implantation flux by the 3 He(n,p) 3 H reaction. This experiment will simulate the fusion reactor radiation environment. We also plan to verify a supporting analytical code development program, in progress, by these experiments

  11. Dental-Implantate und ihre Werkstoffe

    Science.gov (United States)

    Newesely, Heinrich

    1983-07-01

    Some new trends in materials for dental implants, which also effect in the operative techniques and implant design, are described. Advantages and shortcomings of the different material types are exemplified and correlated with their bioinert resp. bioactive functions. The practical interest in metallic implants focussed in titanium resp. oxide ceramics in the ceramic field, whereas the special goal of implant research follows from the improvement of the bioactive principle with loaded calcium phosphate implants.

  12. Biodegradable Implants in Orthopaedics and Traumatology

    OpenAIRE

    YETKIN, Haluk

    2014-01-01

    Biodegradable implants are an alternative to metallic implants and have the advantage of not being necessary to remove once the fracture has healed. Twenty-two patients with fractures were treated with biodegradable implants. There were osteolysis in eleven patients; however, no serious complication was encountered. Although biodegradable implants are expensive, a second surgical procedure to remove the implants is not necessary, relieving the patient of the related costs and risks.

  13. Basics of clinical diagnosis in implant dentistry

    Directory of Open Access Journals (Sweden)

    Manu Rathee

    2015-01-01

    Full Text Available Implant-based prosthetic rehabilitation requires an understanding of associated anatomical structures. The ultimate predictability of an implant site is determined by the existing anatomy as related to dentition and the associated hard and soft tissues. Meticulous clinical assessment helps in determining the suitability of the potential site for implant placement. The purpose of this article is to present the clinical assessment for dental implants' placement to modulate peri-implant tissue characteristics in individual clinical need.

  14. Provisional prostheses during ridge augmentation and implant dentistry.

    Science.gov (United States)

    Livada, Rania; Hottel, Timothy L; Shiloah, Jacob

    2013-01-01

    Recent advancements in ridge augmentation and bone regeneration have expanded the pool of patients that could benefit from dental implants. However, providing the patient with a temporary prosthesis during the wound healing phase without impairing the process is a challenging task. This article summarizes available information pertaining to provisional prostheses, both tooth-supported and soft tissue-supported, that may meet the patient needs. The advantages and disadvantages of each class of prosthesis, along with indications and contraindications, were taken into consideration to aid the restorative dentist in choosing the optimal provisional for their patients.

  15. Fuel retention under elevated wall temperature in KSTAR with a carbon wall

    Science.gov (United States)

    Cao, B.; Hong, S. H.

    2018-03-01

    The fuel retention during KSTAR discharges with elevated wall temperature (150 °C) has been studied by using the method of global particle balance. The results show that the elevated wall temperature could reduce the dynamic retention via implantation and absorption, especially for the short pulse shots with large injected fuel particles. There is no signature changing of long-term retention, which related to co-deposition, under elevated wall temperature. For soft-landing shots (normal shots), the exhausted fuel particles during discharges is larger with elevated wall temperature than without, but the exhausted particles after discharges within 90 s looks similar. The outgassing particles because of disruption could be exhausted within 15 s.

  16. Dannelsen af den ansvarlige elev

    DEFF Research Database (Denmark)

    Larsen, Jesper

    2010-01-01

    Denne artikel handler om den del af lærergerningen, der har at gøre med udarbejdelse af elevplaner. Der tages udgangspunkt i en foucaultsk forståelse, hvor beskrivelsen af den enkelte elev udtrykker et særligt normativt ideal om, hvilke former for elevhed der er de ønskværdige i den danske...

  17. Methylphenidatinduceret ST-elevations-myokardieinfarkt

    DEFF Research Database (Denmark)

    Ruwald, Martin Huth; Ruwald, Anne-Christine Huth; Tønder, Niels

    2012-01-01

    Adult attention deficit and hyperkinetic disorder (ADHD) is increasingly diagnosed and treated with methylphenidate. We present the case of an 20 year-old man, who was diagnosed with ADHD and suffered a ST elevation acute myocardial infarction due to coronary vasospasm related to an overdose...

  18. Elevated lactate during psychogenic hyperventilation

    NARCIS (Netherlands)

    ter Avest, E.; Patist, F. M.; ter Maaten, J. C.; Nijsten, M. W. N.

    Study objective Elevated arterial lactate levels are closely related to morbidity and mortality in various patient categories. In the present retrospective study, the relation between arterial lactate, partial pressure of carbon dioxide (Pco(2)) and pH was systematically investigated in patients who

  19. Body Implanted Medical Device Communications

    Science.gov (United States)

    Yazdandoost, Kamya Yekeh; Kohno, Ryuji

    The medical care day by day and more and more is associated with and reliant upon concepts and advances of electronics and electromagnetics. Numerous medical devices are implanted in the body for medical use. Tissue implanted devices are of great interest for wireless medical applications due to the promising of different clinical usage to promote a patient independence. It can be used in hospitals, health care facilities and home to transmit patient measurement data, such as pulse and respiration rates to a nearby receiver, permitting greater patient mobility and increased comfort. As this service permits remote monitoring of several patients simultaneously it could also potentially decrease health care costs. Advancement in radio frequency communications and miniaturization of bioelectronics are supporting medical implant applications. A central component of wireless implanted device is an antenna and there are several issues to consider when designing an in-body antenna, including power consumption, size, frequency, biocompatibility and the unique RF transmission challenges posed by the human body. The radiation characteristics of such devices are important in terms of both safety and performance. The implanted antenna and human body as a medium for wireless communication are discussed over Medical Implant Communications Service (MICS) band in the frequency range of 402-405MHz.

  20. Cochlear implants and medical tourism.

    Science.gov (United States)

    McKinnon, Brian J; Bhatt, Nishant

    2010-09-01

    To compare the costs of medical tourism in cochlear implant surgery performed in India as compared to the United States. In addition, the cost savings of obtaining cochlear implant surgery in India were compare d to those of other surgical interventions obtained as a medical tourist. Searches were conducted on Medline and Google using the search terms: 'medical tourism', 'medical offshoring', 'medical outsourcing', 'cochlear implants' and 'cochlear implantation'. The information regarding cost of medical treatment was obtained from personal communication with individuals familiar with India's cochlear implantation medical tourism industry. The range of cost depended on length of stay as well as the device chosen. Generally the cost, inclusive of travel, surgery and device, was in the range of $21,000-30,000, as compared to a cost range of $40,000-$60,000 in the US. With the escalating cost of healthcare in the United States, it is not surprising that some patients would seek to obtain surgical care overseas at a fraction of the cost. Participants in medical tourism often have financial resources, but lack health insurance coverage. While cardiovascular and orthopedic surgery performed outside the United States in India at centers that cater to medical tourists are often performed at one-quarter to one-third of the cost that would have been paid in the United States, the cost differential for cochlear implants is not nearly as favorable.

  1. Implantation damage in silicon devices

    International Nuclear Information System (INIS)

    Nicholas, K.H.

    1977-01-01

    Ion implantation, is an attractive technique for producing doped layers in silicon devices but the implantation process involves disruption of the lattice and defects are formed, which can degrade device properties. Methods of minimizing such damage are discussed and direct comparisons made between implantation and diffusion techniques in terms of defects in the final devices and the electrical performance of the devices. Defects are produced in the silicon lattice during implantation but they are annealed to form secondary defects even at room temperature. The annealing can be at a low temperature ( 0 C) when migration of defects in silicon in generally small, or at high temperature when they can grow well beyond the implanted region. The defect structures can be complicated by impurity atoms knocked into the silicon from surface layers by the implantation. Defects can also be produced within layers on top of the silicon and these can be very important in device fabrication. In addition to affecting the electrical properties of the final device, defects produced during fabrication may influence the chemical properties of the materials. The use of these properties to improve devices are discussed as well as the degradation they can cause. (author)

  2. The vestibular implant: Quo vadis?

    Directory of Open Access Journals (Sweden)

    Raymond eVan De Berg

    2011-08-01

    Full Text Available AbstractObjective: to assess the progress of the development of the vestibular implant and its feasibility short-term. Data sources: a search was performed in Pubmed, Medline and Embase. Key words used were vestibular prosth* and vestibular implant. The only search limit was language: English or Dutch. Additional sources were medical books, conference lectures and our personal experience with per-operative vestibular stimulation in patients selected for cochlear implantation.Study selection: all studies about the vestibular implant and related topics were included and evaluated by two reviewers. No study was excluded since every study investigated different aspects of the vestibular implant. Data extraction and synthesis: data was extracted by the first author from selected reports, supplemented by additional information, medical books conference lectures. Since each study had its own point of interest with its own outcomes, it was not possible to compare data of different studies. Conclusion: to use a basic vestibular implant in humans seems feasible in the very near future. Investigations show that electric stimulation of the canal nerves induces a nystagmus which corresponds to the plane of the canal which is innervated by the stimulated nerve branch. The brain is able to adapt to a higher baseline stimulation, while still reacting on a dynamic component. The best response will be achieved by a combination of the optimal stimulus (stimulus profile, stimulus location, precompensation, complemented by central vestibular adaptation. The degree of response will probably vary between individuals, depending on pathology and their ability to adapt.

  3. Imaging of common breast implants and implant-related complications: A pictorial essay.

    Science.gov (United States)

    Shah, Amisha T; Jankharia, Bijal B

    2016-01-01

    The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.

  4. Why are mini-implants lost: the value of the implantation technique!

    Science.gov (United States)

    Romano, Fabio Lourenço; Consolaro, Alberto

    2015-01-01

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  5. Why are mini-implants lost: The value of the implantation technique!

    Directory of Open Access Journals (Sweden)

    Fabio Lourenço Romano

    2015-02-01

    Full Text Available The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1 Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2 Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3 Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4 The more precise the lancing procedures, the better the implant placement technique; 5 Self-drilling does not mean higher pressures; 6 Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  6. Imaging of common breast implants and implant-related complications: A pictorial essay

    Directory of Open Access Journals (Sweden)

    Amisha T Shah

    2016-01-01

    Full Text Available The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.

  7. Grammatical Impairments in PPA.

    Science.gov (United States)

    Thompson, Cynthia K; Mack, Jennifer E

    2014-09-01

    Grammatical impairments are commonly observed in the agrammatic subtype of primary progressive aphasia (PPA-G), whereas grammatical processing is relatively preserved in logopenic (PPA-L) and semantic (PPA-S) subtypes. We review research on grammatical deficits in PPA and associated neural mechanisms, with discussion focused on production and comprehension of four aspects of morphosyntactic structure: grammatical morphology, functional categories, verbs and verb argument structure, and complex syntactic structures. We also address assessment of grammatical deficits in PPA, with emphasis on behavioral tests of grammatical processing. Finally, we address research examining the effects of treatment for progressive grammatical impairments. PPA-G is associated with grammatical deficits that are evident across linguistic domains in both production and comprehension. PPA-G is associated with damage to regions including the left inferior frontal gyrus (IFG) and dorsal white matter tracts, which have been linked to impaired comprehension and production of complex sentences. Detailing grammatical deficits in PPA is important for estimating the trajectory of language decline and associated neuropathology. We, therefore, highlight several new assessment tools for examining different aspects of morphosyntactic processing in PPA. Individuals with PPA-G present with agrammatic deficit patterns distinct from those associated with PPA-L and PPA-S, but similar to those seen in agrammatism resulting from stroke, and patterns of cortical atrophy and white matter changes associated with PPA-G have been identified. Methods for clinical evaluation of agrammatism, focusing on comprehension and production of grammatical morphology, functional categories, verbs and verb argument structure, and complex syntactic structures are recommended and tools for this are emerging in the literature. Further research is needed to investigate the real-time processes underlying grammatical impairments in

  8. Implantate in der Augenheilkunde

    Science.gov (United States)

    Dresp, Joachim H.

    Im Bereich der Augenheilkunde findet sich die weltweit am häufigsten ausgeführte chirurgische Massnahme, die operative Behandlung des Grauen Stars: die Katarakt. Bei der Katarakt handelt es sich um eine Eintrübung der natürlichen Augenlinse, die sich je nach Stadium der Erkrankung leicht opak, über milchig bis zu bräunlich präsentiert. Mit dieser Zunahme der Undurchlässigkeit für das sichtbare Licht geht eine Abnahme des Sehvermögens einher, die bis zur totalen Erblindung führen kann. Bedingt durch die sehr eingeschränkten chirurgischen Möglichkeiten in den Ländern der Dritten Welt ist die Katarakt die Erblindungsursache Nummer 1 in der Welt. Ganz im Gegensatz hierzu ist in den industrialisierten Ländern Europas, Amerikas und Asiens die Katarakt-OP die sicherste chirurgische Intervention. In der Augenheilkunde werden Implantate aller drei Aggregatszustände verwendet.

  9. Recovery of Ventriculo-Atrial Conduction after Adrenaline in Patients Implanted with Pacemakers.

    Science.gov (United States)

    Cismaru, Gabriel; Gusetu, Gabriel; Muresan, Lucian; Rosu, Radu; Andronache, Marius; Matuz, Roxana; Puiu, Mihai; Mester, Petru; Miclaus, Maria; Pop, Dana; Mircea, Petru Adrian; Zdrenghea, Dumitru

    2015-07-01

    Ventriculo-atrial (VA) conduction can have negative consequences for patients with implanted pacemakers and defibrillators. There is concern whether impaired VA conduction could recover during stressful situations. Although the influence of isoproterenol and atropine are well established, the effect of adrenaline has not been studied systematically. The objective of this study was to determine if adrenaline can facilitate recovery of VA conduction in patients implanted with pacemakers. A prospective study was conducted on 61 consecutive patients during a 4-month period (April-July 2014). The presence of VA conduction was assessed during the pacemaker implantation procedure. In case of an impaired VA conduction, adrenaline infusio was used as a stress surrogate to test conduction recovery. The indications for pacemaker implantation were: sinus node dysfunction in 18 patients, atrioventricular (AV) block in 40 patients, binodal dysfunction (sinus node+ AV node) in two patients and other (carotid sinus syndrome) in one patient. In the basal state, 15/61 (24.6%) presented spontaneous VA conduction and 46/61 (75.4%) had no VA conduction. After administration of adrenaline, there was VA conduction recovery in 5/46 (10.9%) patients. Adrenaline infusion produced recovery of VA conduction in 10.9% of patients with absent VA conduction in a basal state. Recovery of VA conduction during physiological or pathological stresses could be responsible for the pacemaker syndrome, PMT episodes, or certain implantable cardiac defibrillator detection issues. © 2015 Wiley Periodicals, Inc.

  10. Oxidative stress in mouse sperm impairs embryo development, fetal growth and alters adiposity and glucose regulation in female offspring.

    Directory of Open Access Journals (Sweden)

    Michelle Lane

    Full Text Available Paternal health cues are able to program the health of the next generation however the mechanism for this transmission is unknown. Reactive oxygen species (ROS are increased in many paternal pathologies, some of which program offspring health, and are known to induce DNA damage and alter the methylation pattern of chromatin. We therefore investigated whether a chemically induced increase of ROS in sperm impairs embryo, pregnancy and offspring health. Mouse sperm was exposed to 1500 µM of hydrogen peroxide (H2O2, which induced oxidative damage, however did not affect sperm motility or the ability to bind and fertilize an oocyte. Sperm treated with H2O2 delayed on-time development of subsequent embryos, decreased the ratio of inner cell mass cells (ICM in the resulting blastocyst and reduced implantation rates. Crown-rump length at day 18 of gestation was also reduced in offspring produced by H2O2 treated sperm. Female offspring from H2O2 treated sperm were smaller, became glucose intolerant and accumulated increased levels of adipose tissue compared to control female offspring. Interestingly male offspring phenotype was less severe with increases in fat depots only seen at 4 weeks of age, which was restored to that of control offspring later in life, demonstrating sex-specific impacts on offspring. This study implicates elevated sperm ROS concentrations, which are common to many paternal health pathologies, as a mediator of programming offspring for metabolic syndrome and obesity.

  11. Speech and language development in cognitively delayed children with cochlear implants.

    Science.gov (United States)

    Holt, Rachael Frush; Kirk, Karen Iler

    2005-04-01

    The primary goals of this investigation were to examine the speech and language development of deaf children with cochlear implants and mild cognitive delay and to compare their gains with those of children with cochlear implants who do not have this additional impairment. We retrospectively examined the speech and language development of 69 children with pre-lingual deafness. The experimental group consisted of 19 children with cognitive delays and no other disabilities (mean age at implantation = 38 months). The control group consisted of 50 children who did not have cognitive delays or any other identified disability. The control group was stratified by primary communication mode: half used total communication (mean age at implantation = 32 months) and the other half used oral communication (mean age at implantation = 26 months). Children were tested on a variety of standard speech and language measures and one test of auditory skill development at 6-month intervals. The results from each test were collapsed from blocks of two consecutive 6-month intervals to calculate group mean scores before implantation and at 1-year intervals after implantation. The children with cognitive delays and those without such delays demonstrated significant improvement in their speech and language skills over time on every test administered. Children with cognitive delays had significantly lower scores than typically developing children on two of the three measures of receptive and expressive language and had significantly slower rates of auditory-only sentence recognition development. Finally, there were no significant group differences in auditory skill development based on parental reports or in auditory-only or multimodal word recognition. The results suggest that deaf children with mild cognitive impairments benefit from cochlear implantation. Specifically, improvements are evident in their ability to perceive speech and in their reception and use of language. However, it may

  12. Including persistency of impairment in mild cognitive impairment classification enhances prediction of 5-year decline.

    Science.gov (United States)

    Vandermorris, Susan; Hultsch, David F; Hunter, Michael A; MacDonald, Stuart W S; Strauss, Esther

    2011-02-01

    Although older adults with Mild Cognitive Impairment (MCI) show elevated rates of conversion to dementia as a group, heterogeneity of outcomes is common at the individual level. Using data from a prospective 5-year longitudinal investigation of cognitive change in healthy older adults (N = 262, aged 64-92 years), this study addressed limitations in contemporary MCI identification procedures which rely on single occasion assessment ("Single-Assessment [SA] MCI") by evaluating an alternate operational definition of MCI requiring evidence of persistent cognitive impairment over multiple-testing sessions ("Multiple-Assessment [MA] MCI"). As hypothesized, prevalence of SA-MCI exceeded that of MA-MCI. Further, the MA-MCI groups showed lower baseline cognitive and functional performance and steeper cognitive decline compared with Control and SA-MCI group. Results are discussed with reference to retest effects and clinical implications.

  13. Working with impairments

    OpenAIRE

    Maroesjka Versantvoort; Patricia van Echtelt

    2012-01-01

    Original title: Belemmerd aan het werk The Netherlands was long known as a country with high sickness absenteeism rates and a burgeoning group of people who were unfit for work. In response to this, many policy measures have been introduced in recent decades which attempt to limit the benefit volume and foster the reintegration of people with health impairments. What is the position of the Netherlands today in this regard? The main trends in sickness absenteeism, degree of incapacity for work...

  14. Age-Related Sensory Impairments and Risk of Cognitive Impairment

    Science.gov (United States)

    Fischer, Mary E; Cruickshanks, Karen J.; Schubert, Carla R; Pinto, Alex A; Carlsson, Cynthia M; Klein, Barbara EK; Klein, Ronald; Tweed, Ted S.

    2016-01-01

    Background/Objectives To evaluate the associations of sensory impairments with the 10-year risk of cognitive impairment. Previous work has primarily focused on the relationship between a single sensory system and cognition. Design The Epidemiology of Hearing Loss Study (EHLS) is a longitudinal, population-based study of aging in the Beaver Dam, WI community. Baseline examinations were conducted in 1993 and follow-up exams have been conducted every 5 years. Setting General community Participants EHLS members without cognitive impairment at EHLS-2 (1998–2000). There were 1,884 participants (mean age = 66.7 years) with complete EHLS-2 sensory data and follow-up information. Measurements Cognitive impairment was a Mini-Mental State Examination score of impairment was a pure-tone average of hearing thresholds (0.5, 1, 2 and 4 kHz) of > 25 decibel Hearing Level in either ear. Visual impairment was Pelli-Robson contrast sensitivity of impairment was a San Diego Odor Identification Test score of impairment were independently associated with cognitive impairment risk [Hearing: Hazard Ratio (HR) = 1.90, 95% Confidence Interval (C.I.) = 1.11, 3.26; Vision: HR = 2.05, 95% C.I. = 1.24, 3.38; Olfaction: HR = 3.92, 95% C.I. = 2.45, 6.26]. However, 85% with hearing impairment, 81% with visual impairment, and 76% with olfactory impairment did not develop cognitive impairment during follow-up. Conclusion The relationship between sensory impairment and cognitive impairment was not unique to one sensory system suggesting sensorineural health may be a marker of brain aging. The development of a combined sensorineurocognitive measure may be useful in uncovering mechanisms of healthy brain aging. PMID:27611845

  15. 5-HT1A receptor blockade targeting the basolateral amygdala improved stress-induced impairment of memory consolidation and retrieval in rats.

    Science.gov (United States)

    Sardari, M; Rezayof, A; Zarrindast, M-R

    2015-08-06

    The aim of the present study was to investigate the possible role of basolateral amygdala (BLA) 5-HT1A receptors in memory formation under stress. We also examined whether the blockade of these receptors is involved in stress-induced state-dependent memory. Adult male Wistar rats received cannula implants that bilaterally targeted the BLA. Long-term memory was examined using the step-through type of passive avoidance task. Behavioral stress was evoked by exposure to an elevated platform (EP) for 10, 20 and 30min. Post-training exposure to acute stress (30min) impaired the memory consolidation. In addition, pre-test exposure to acute stress-(20 and 30min) induced the impairment of memory retrieval. Interestingly, the memory impairment induced by post-training exposure to stress was restored in the animals that received 20- or 30-min pre-test stress exposure, suggesting stress-induced state-dependent memory retrieval. Post-training BLA-targeted injection of a selective 5-HT1A receptor antagonist, (S)-WAY-100135 (2μg/rat), prevented the impairing effect of stress on memory consolidation. Pre-test injection of the same doses of (S)-WAY-100135 that was targeted to the BLA also reversed stress-induced memory retrieval impairment. It should be considered that post-training or pre-test BLA-targeted injection of (S)-WAY-100135 (0.5-2μg/rat) by itself had no effect on the memory formation. Moreover, pre-test injection of (S)-WAY-100135 (2μg/rat) that targeted the BLA inhibited the stress-induced state-dependent memory retrieval. Taken together, our findings suggest that post-training or pre-test exposure to acute stress induced the impairment of memory consolidation, retrieval and state-dependent learning. The BLA 5-HT1A receptors have a critical role in learning and memory under stress. Copyright © 2015 IBRO. Published by Elsevier Ltd. All rights reserved.

  16. Precision of fit between implant impression coping and implant replica pairs for three implant systems.

    Science.gov (United States)

    Nicoll, Roxanna J; Sun, Albert; Haney, Stephan; Turkyilmaz, Ilser

    2013-01-01

    The fabrication of an accurately fitting implant-supported fixed prosthesis requires multiple steps, the first of which is assembling the impression coping on the implant. An imprecise fit of the impression coping on the implant will cause errors that will be magnified in subsequent steps of prosthesis fabrication. The purpose of this study was to characterize the 3-dimensional (3D) precision of fit between impression coping and implant replica pairs for 3 implant systems. The selected implant systems represent the 3 main joint types used in implant dentistry: external hexagonal, internal trilobe, and internal conical. Ten impression copings and 10 implant replicas from each of the 3 systems, B (Brånemark System), R (NobelReplace Select), and A (NobelActive) were paired. A standardized aluminum test body was luted to each impression coping, and the corresponding implant replica was embedded in a stone base. A coordinate measuring machine was used to quantify the maximum range of displacement in a vertical direction as a function of the tightening force applied to the guide pin. Maximum angular displacement in a horizontal plane was measured as a function of manual clockwise or counterclockwise rotation. Vertical and rotational positioning was analyzed by using 1-way analysis of variance (ANOVA). The Fisher protected least significant difference (PLSD) multiple comparisons test of the means was applied when the F-test in the ANOVA was significant (α=.05). The mean and standard deviation for change in the vertical positioning of impression copings was 4.3 ±2.1 μm for implant system B, 2.8 ±4.2 μm for implant system R, and 20.6 ±8.8 μm for implant system A. The mean and standard deviation for rotational positioning was 3.21 ±0.98 degrees for system B, 2.58 ±1.03 degrees for system R, and 5.30 ±0.79 degrees for system A. The P-value for vertical positioning between groups A and B and between groups A and R was <.001. No significant differences were found for

  17. Assessment of Hearing Impaired Youth.

    Science.gov (United States)

    Hicks, Doin E., Ed.; And Others

    1980-01-01

    The issue of Directions contains 11 articles on assessment of hearing impaired individuals. Entries have the following titles and authors: "Classroom Assessment Techniques for Hearing Impaired Students--A Literature Review" (B. McKee, M. Hausknecht); "Informal Assessment of Hearing Impaired Students In the Classroom" (B. Culhane, R. Hein);…

  18. Elevator deflections on the icing process

    Science.gov (United States)

    Britton, Randall K.

    1990-01-01

    The effect of elevator deflection of the horizontal stabilizer for certain icing parameters is investigated. Elevator deflection can severely change the lower and upper leading-edge impingement limits, and ice can accrete on the elevator itself. Also, elevator deflection had practically no effect on the maximum local collection efficiency. It is shown that for severe icing conditions (large water droplets), elevator deflections that increase the projected height of the airfoil can significantly increase the total collection efficiency of the airfoil.

  19. The effects of implant topography on osseointegration under estrogen deficiency induced osteoporotic conditions: Histomorphometric, transcriptional and ultrastructural analysis.

    Science.gov (United States)

    Du, Zhibin; Xiao, Yin; Hashimi, Saeed; Hamlet, Stephen M; Ivanovski, Saso

    2016-09-15

    Compromised bone quality and/or healing in osteoporosis are recognised risk factors for impaired dental implant osseointegration. This study examined the effects of (1) experimentally induced osteoporosis on titanium implant osseointegration and (2) the effect of modified implant surface topography on osseointegration under osteoporosis-like conditions. Machined and micro-roughened surface implants were placed into the maxillary first molar root socket of 64 ovariectomised and sham-operated Sprague-Dawley rats. Subsequent histological and SEM observations showed tissue maturation on the micro-rough surfaced implants in ovariectomised animals as early as 3days post-implantation. The degree of osseointegration was also significantly higher around the micro-rough implants in ovariectomised animals after 14days of healing although by day 28, similar levels of osseointegration were found for all test groups. The micro-rough implants significantly increased the early (day 3) gene expression of alkaline phosphatase, osteocalcin, receptor activator of nuclear factor kappa-B ligand and dentin matrix protein 1 in implant adherent cells. By day 7, the expression of inflammatory genes decreased while the expression of the osteogenic markers increased further although there were few statistically significant differences between the micro-rough and machined surfaces. Osteocyte morphology was also affected by estrogen deficiency with the size of the cells being reduced in trabecular bone. In conclusion, estrogen deficiency induced osteoporotic conditions negatively influenced the early osseointegration of machined implants while micro-rough implants compensated for these deleterious effects by enhancing osteogenic cell differentiation on the implant surface. Lower bone density, poor bone quality and osseous microstructural changes are all features characteristic of osteoporosis that may impair the osseointegration of dental implants. Using a clinically relevant trabecular bone

  20. Når elever producerer

    DEFF Research Database (Denmark)

    Bremholm, Jesper; Hansen, Rune; Slot, Marie Falkesgaard

    2017-01-01

    Dette kapitel præsenterer centrale resultater fra studiet Elevopgaver og elevproduktion i det 21. århundrede der blandt andet rummer den første større kvantitative undersøgelse af opgavedidaktik og elevers produktive arbejde i den danske grundskole. Studiet omfatter også en kvalitativ del, og i...... undersøgelsen præsenteres og diskuteres gennem en række konkrete eksempler fra de berørte fag. I forhold til elevers produktive arbejde peger undersøgelsens resultater både på potentialer og særlige barrierer i forbindelse med at udvikle en kompetenceorienteret undervisning. I kapitlet argumenteres desuden...

  1. Læring mellem elever

    DEFF Research Database (Denmark)

    Georgsen, Marianne; Davidsen, Jacob

    2010-01-01

    I denne rapport præsenteres resultater fra følgeforskningen til projektet Læring gennem Bevægelse, som er gennemført på Søndervangskolen i Hammel i perioden august 2009 - maj 2010. Projektet er gennemført i samspil mellem lærere, it-vejleder, elever og skolens ledelse. Projektets overordnede formål...

  2. Science on a space elevator

    Energy Technology Data Exchange (ETDEWEB)

    Laubscher, B. E. (Bryan E.); Jorgensen, A. M. (Anders M.)

    2004-01-01

    The Space Elevator (SE) represents a major paradigm shift in space access. If the SE's promise of low cost access can be realized, everything becomes economically more feasible to accomplish in space. In this paper we describe in-situ science stations mounted on a science-dedicated space elevator tether. The concept presented here involves a carbon nanotube ribbon that is constructed by an existing space elevator and then science sensors are stationed along the ribbon at differing altitudes. The finished ribbon can be moved across the earth to the position at which its scientific measurements are to be taken. The ability to station scientific, in-situ instrumentation at different altitudes for round-the-clock observations is a unique capability of the SE. The environments that the science packages sense range from the troposphere out beyond the magnetopause of the magnetosphere on the solar side of the earth. Therefore, the very end of the SE can sense the solar wind. The measurements at various points along its length include temperature, pressure, density, sampling, chemical analyses, wind speed, turbulence, free oxygen, electromagnetic radiation, cosmic rays, energetic particles and plasmas in the earth's magnetosphere and the solar wind. There exist some altitudes that are difficult to access with aircraft or balloons or rockets and so remain relatively unexplored. The space elevator solves these problems and opens these regions up to in-situ measurements. Without the need for propulsion, the SE provides a more benign and pristine environment for atmospheric measurements than available with powered aircraft. Moreover, replacing and upgrading instrumentation is expected to be very cost effective with the SE. Moving and stationing the science SE affords the opportunity to sense multiple regions of the atmosphere. The SE's geosynchronous, orbital motion through the magnetosphere, albeit nominally with Earth's magnetic field, will trace a plane

  3. Language development in Japanese children who receive cochlear implant and/or hearing aid.

    Science.gov (United States)

    Iwasaki, Satoshi; Nishio, Shinya; Moteki, Hideaki; Takumi, Yutaka; Fukushima, Kunihiro; Kasai, Norio; Usami, Shin-Ichi

    2012-03-01

    This study aimed to investigate a wide variety of factors that influence auditory, speech, and language development following pediatric cochlear implantation (CI). Prospective collection of language tested data in profound hearing-impaired children. Pediatric CI can potentially be effective to development of practical communication skills and early implantation is more effective. We proposed a set of language tests (assessment package of the language development for Japanese hearing-impaired children; ALADJIN) consisting of communication skills testing (test for question-answer interaction development; TQAID), comprehensive (Peabody Picture Vocabulary Test-Revised; PVT-R and Standardized Comprehension Test for Abstract Words; SCTAW) and productive vocabulary (Word Fluency Test; WFT), and comprehensive and productive syntax (Syntactic processing Test for Aphasia; STA). Of 638 hearing-impaired children recruited for this study, 282 (44.2%) with >70 dB hearing impairment had undergone CI. After excluding children with low birth weight (11 points on the Pervasive Developmental Disorder ASJ Rating Scale for the test of autistic tendency, and those better than those in HA-only users. The scores for PVT-R (pbetter than those in HA-only users. STA and TQAID scores in CI-HA users were significantly (pbetter than those in unilateral CI-only users. The high correlation (r=0.52) has been found between the age of CI and maximum speech discrimination score. The scores of speech and language tests in the implanted children before 24 months of age have been better than those in the implanted children after 24 months of age. We could indicate that CI was effective for language development in Japanese hearing-impaired children and early CI was more effective for productive vocabulary and syntax. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  4. Falha prematura em implantes orais = Early oral implant failures

    Directory of Open Access Journals (Sweden)

    Fadanelli, Alexandro Bianchi

    2005-01-01

    Full Text Available Atualmente, ainda há uma percentagem significativa de fracassos de implantes na prática clínica, causando transtorno para o profissional e para o paciente. O objetivo deste estudo foi avaliar a bibliografia disponível sobre o assunto, apresentar um caso clínico e discutir os aspectos relacionados aos insucessos na terapia com implantes ocorridos durante o período de osteointegração. A avaliação da literatura mostrou haverem múltiplos fatores possivelmente envolvidos nas falhas de implantes, sendo que através do estudo das falhas pode-se minimizar sua ocorrência

  5. Medical implants and methods of making medical implants

    Science.gov (United States)

    Shaw, Wendy J; Yonker, Clement R; Fulton, John L; Tarasevich, Barbara J; McClain, James B; Taylor, Doug

    2014-09-16

    A medical implant device having a substrate with an oxidized surface and a silane derivative coating covalently bonded to the oxidized surface. A bioactive agent is covalently bonded to the silane derivative coating. An implantable stent device including a stent core having an oxidized surface with a layer of silane derivative covalently bonded thereto. A spacer layer comprising polyethylene glycol (PEG) is covalently bonded to the layer of silane derivative and a protein is covalently bonded to the PEG. A method of making a medical implant device including providing a substrate having a surface, oxidizing the surface and reacting with derivitized silane to form a silane coating covalently bonded to the surface. A bioactive agent is then covalently bonded to the silane coating. In particular instances, an additional coating of bio-absorbable polymer and/or pharmaceutical agent is deposited over the bioactive agent.

  6. An Unusual Bone Loss Around Implants

    Directory of Open Access Journals (Sweden)

    Amirreza Rokn

    2013-01-01

    Full Text Available AbstractPre-implant disease is an inflammatory process, which can affect the surrounding tissues of a functional Osseointegrated implant that is usually as a result of a disequilibrium between the micro-flora and the body defense system.This case reports a 57 years old male with unusual bone loss around dental implants.This was an unusual case of peri-implantitis which occurred only in the implants on one side of the mouth although they all were unloaded implants.

  7. Occlusal considerations for dental implant restorations.

    Science.gov (United States)

    Bergmann, Ranier H

    2014-01-01

    When placed, dental implants are put into an ever-changing oral environment in which teeth can continue to migrate. Yet, the implants themselves are ankylosed. This can lead to occlusal instability. Teeth may continue to erupt, leaving the implants in infraocclusion. Teeth may move mesially away from an implant, requiring modification to close an open contact point. Friction in the connection between teeth and implants can lead to intrusion of teeth and damage to the periodontal attachment apparatus. Implant occlusion with shallow incisal guidance minimizes lateral and tipping forces. Cross-arch stabilization allows the best distribution of occlusal forces. The choice of restorative materials influences long-term occlusal stability.

  8. Current trends in ion implantation

    International Nuclear Information System (INIS)

    Gwilliam, R.M.

    2001-01-01

    As semiconductor device dimensions continue to shrink, the drive beyond 250 nm is creating significant problems for the device processor. In particular, trends toward shallower-junctions, lower thermal budgets and simplified processing steps present severe challenges to ion implantation. In parallel with greater control of the implant process goes the need for a better understanding of the physical processes involved during implantation and subsequent activation annealing. For instance, the need for an understanding of dopant-defect interaction is paramount as defects mediate a number of technologically important phenomena such as transient enhanced diffusion and impurity gettering. This paper will outline the current trends in the ion implantation and some of the challenges it faces in the next decade, as described in the semiconductor roadmap. It will highlight some recent positron annihilation work that has made a contribution to addressing one of these challenges, namely the need for tighter control of implant uniformity and dose. Additionally, some vacancy-mediated processes are described with the implication that these may provide areas in which positron annihilation spectroscopy could make a significant contribution. (orig.)

  9. Composite fibrous glaucoma drainage implant

    Science.gov (United States)

    Klapstova, A.; Horakova, J.; Shynkarenko, A.; Lukas, D.

    2017-10-01

    Glaucoma is a frequent reason of loss vision. It is usually caused by increased intraocular pressure leading to damage of optic nerve head. This work deals with the development of fibrous structure suitable for glaucoma drainage implants (GDI). Commercially produced metallic glaucoma implants are very effective in lowering intraocular pressure. However, these implants may cause adverse events such as damage to adjacent tissue, fibrosis, hypotony or many others [1]. The aim of this study is to reduce undesirable properties of currently produced drains and improve their properties by creating of the composite fibrous drain for achieve a normal intraocular pressure. Two types of electrospinning technologies were used for the production of very small tubular implants. First type was focused for production of outer part of tubular drain and the second type of electrospinning method made the inner part of shape follows the connections of both parts. Complete implant had a special properties suitable for drainage of fluid. Morphological parameters, liquid transport tests and in-vitro cell adhesion tests were detected.

  10. Cranioplasty with individual titanium implants

    Science.gov (United States)

    Mishinov, S.; Stupak, V.; Sadovoy, M.; Mamonova, E.; Koporushko, N.; Larkin, V.; Novokshonov, A.; Dolzhenko, D.; Panchenko, A.; Desyatykh, I.; Krasovsky, I.

    2017-09-01

    Cranioplasty is the second procedure in the history of neurosurgery after trepanation, and it is still relevant despite the development of civilization and progress in medicine. Each cranioplasty operation is unique because there are no two patients with identical defects of the skull bones. The development of Direct Metal Laser Sintering (DMLS) technique opened up the possibility of direct implant printing of titanium, a biocompatible metal used in medicine. This eliminates the need for producing any intermediate products to create the desired implant. We have produced 8 patient-specific titanium implants using this technique for patients who underwent different decompressive cranioectomies associated with bone tumors. Follow-up duration ranged from 6 to 12 months. We observed no implant-related reactions or complications. In all cases of reconstructive neurosurgery we achieved good clinical and aesthetic results. The analysis of the literature and our own experience in three-dimensional modeling, prototyping, and printing suggests that direct laser sintering of titanium is the optimal method to produce biocompatible surgical implants.

  11. Aqueous shunt implantation in glaucoma

    Directory of Open Access Journals (Sweden)

    Jing Wang

    2017-01-01

    Full Text Available Aqueous shunts or glaucoma drainage devices are increasingly utilized in the management of refractory glaucoma. The general design of the most commonly-used shunts is based on the principles of the Molteno implant: ie. a permanent sclerostomy (tube, a predetermined bleb area (plate and diversion of aqueous humour to the equatorial region and away from the limbal subconjunctival space. These three factors make aqueous shunts more resistant to scarring as compared to trabeculectomy. The two most commonly used shunts are the Ahmed Glaucoma Valve, which contains a flow-restrictor, and the non-valved Baervedlt Glaucoma Implant. While the valved implants have a lower tendency to hypotony and related complications, the non-valved implants with larger, more-biocompatible end plate design, achieve lower intraocular pressures with less encapsulation. Non-valved implants require additional suturing techniques to prevent early hypotony and a number of these methods will be described. Although serious shunt-related infection is rare, corneal decompensation and diplopia are small but significant risks.

  12. Capacitive Feedthroughs for Medical Implants.

    Science.gov (United States)

    Grob, Sven; Tass, Peter A; Hauptmann, Christian

    2016-01-01

    Important technological advances in the last decades paved the road to a great success story for electrically stimulating medical implants, including cochlear implants or implants for deep brain stimulation. However, there are still many challenges in reducing side effects and improving functionality and comfort for the patient. Two of the main challenges are the wish for smaller implants on one hand, and the demand for more stimulation channels on the other hand. But these two aims lead to a conflict of interests. This paper presents a novel design for an electrical feedthrough, the so called capacitive feedthrough, which allows both reducing the size, and increasing the number of included channels. Capacitive feedthroughs combine the functionality of a coupling capacitor and an electrical feedthrough within one and the same structure. The paper also discusses the progress and the challenges of the first produced demonstrators. The concept bears a high potential in improving current feedthrough technology, and could be applied on all kinds of electrical medical implants, even if its implementation might be challenging.

  13. A new system of implant abutment connection: how to improve a two piece implant system sealing.

    Science.gov (United States)

    Grecchi, F; DI Girolamo, M; Cura, F; Candotto, V; Carinci, F

    2017-01-01

    Implant dentistry has become one of the most successful dentistry techniques for replacing missing teeth. The success rate of implant dentistry is above 80%. However, peri-implantitis is a later complication of implant dentistry that if untreated, can lead to implant loss. One of the hypotized causes of peri-implantis is the bacterial leakage at the level of implant-abutment connection. Bacterial leakage is favored to the presence of a micro gap at the implant-abutment interface, allowing microorganisms to penetrate and colonize the inner part of the implant leading to biofilm accumulation and consequently to peri-implantitis development. To identify the capability of the implant to protect the internal space from the external environment, the passage of genetically modified Escherichia coli across implant-abutment interface was evaluated. Implants were immerged in a bacterial culture for twenty-four hours and then bacteria amount was measured inside implant-abutment interface with Real-time PCR. Bacteria were detected inside all studied implants, with a median percentage of 9%. The reported results are better to those of previous studies carried out on different implant systems. Until now, none implant-abutment system has been proven to seal the gap between implant and abutment.

  14. Contemporary Management of ST-Elevation Myocardial Infarction.

    Science.gov (United States)

    Dind, Ashleigh; Allahwala, Usaid; Asrress, Kaleab N; Jolly, Sanjit S; Bhindi, Ravinay

    2017-02-01

    Recent advances have caused a major shift in the way ST-elevation myocardial infarctions are managed. This review explores the pharmacological and interventional techniques that have evidence for improving outcomes and the landmark trials that have sparked change. The new P2Y 12 inhibitors, ticagrelor and prasugrel, have been shown to be superior to clopidogrel in STEMI patients undergoing primary percutaneous coronary intervention. Concurrently, many technical aspects of percutaneous coronary intervention have been further clarified by trial data, with bare-metal stents, routine thrombus aspiration and femoral access showing evidence of inferiority. Ongoing trials will provide more information on the role of non-culprit lesion PCI, bioresorbable vascular scaffolds, mechanical devices in persistent ischaemia and early automatic implantable cardioverter-defibrillators for inducible ventricular tachycardia. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  15. Treatment of an Erratic Extraction Socket for Implant Therapy in a Patient with Chronic Periodontitis

    Science.gov (United States)

    Prabhu, Srividya

    2016-01-01

    As implant therapy becomes more commonplace in daily practice, preservation and preparation of edentulous sites are key. Many times, however, implant therapy may not be considered at the time of tooth extraction and additional measures are not taken to conserve the edentulous site. While the healing process in extraction sockets has been well investigated and bone fill can be expected, there are cases where even when clinicians perform thorough debridement of the sockets, connective tissue infiltration into the socket can occur. This phenomenon, known as “erratic healing,” may be associated with factors that lead to peri-implant disease and should be appropriately managed and treated prior to surgical implant placement. This case report describes the successful management of an erratic healing extraction socket in a 62-year-old Caucasian male patient with chronic periodontitis and the outcomes of an evidence-based treatment protocol performed prior to implant therapy. Careful preoperative analysis and cone beam computed tomography imaging can help detect signs of impaired healing in future implant sites and prevent surgical complications. PMID:27807485

  16. Treatment of an Erratic Extraction Socket for Implant Therapy in a Patient with Chronic Periodontitis

    Directory of Open Access Journals (Sweden)

    Yusuke Hamada

    2016-01-01

    Full Text Available As implant therapy becomes more commonplace in daily practice, preservation and preparation of edentulous sites are key. Many times, however, implant therapy may not be considered at the time of tooth extraction and additional measures are not taken to conserve the edentulous site. While the healing process in extraction sockets has been well investigated and bone fill can be expected, there are cases where even when clinicians perform thorough debridement of the sockets, connective tissue infiltration into the socket can occur. This phenomenon, known as “erratic healing,” may be associated with factors that lead to peri-implant disease and should be appropriately managed and treated prior to surgical implant placement. This case report describes the successful management of an erratic healing extraction socket in a 62-year-old Caucasian male patient with chronic periodontitis and the outcomes of an evidence-based treatment protocol performed prior to implant therapy. Careful preoperative analysis and cone beam computed tomography imaging can help detect signs of impaired healing in future implant sites and prevent surgical complications.

  17. Speech Recognition in Adults With Cochlear Implants: The Effects of Working Memory, Phonological Sensitivity, and Aging.

    Science.gov (United States)

    Moberly, Aaron C; Harris, Michael S; Boyce, Lauren; Nittrouer, Susan

    2017-04-14

    Models of speech recognition suggest that "top-down" linguistic and cognitive functions, such as use of phonotactic constraints and working memory, facilitate recognition under conditions of degradation, such as in noise. The question addressed in this study was what happens to these functions when a listener who has experienced years of hearing loss obtains a cochlear implant. Thirty adults with cochlear implants and 30 age-matched controls with age-normal hearing underwent testing of verbal working memory using digit span and serial recall of words. Phonological capacities were assessed using a lexical decision task and nonword repetition. Recognition of words in sentences in speech-shaped noise was measured. Implant users had only slightly poorer working memory accuracy than did controls and only on serial recall of words; however, phonological sensitivity was highly impaired. Working memory did not facilitate speech recognition in noise for either group. Phonological sensitivity predicted sentence recognition for implant users but not for listeners with normal hearing. Clinical speech recognition outcomes for adult implant users relate to the ability of these users to process phonological information. Results suggest that phonological capacities may serve as potential clinical targets through rehabilitative training. Such novel interventions may be particularly helpful for older adult implant users.

  18. In vivo dendritic cell depletion reduces breeding efficiency, affecting implantation and early placental development in mice.

    Science.gov (United States)

    Krey, Gesa; Frank, Pierre; Shaikly, Valerie; Barrientos, Gabriela; Cordo-Russo, Rosalia; Ringel, Frauke; Moschansky, Petra; Chernukhin, Igor V; Metodiev, Metodi; Fernández, Nelson; Klapp, Burghard F; Arck, Petra C; Blois, Sandra M

    2008-09-01

    Implantation of mammalian embryos into their mother's uterus ensures optimal nourishment and protection throughout development. Complex molecular interactions characterize the implantation process, and an optimal synchronization of the components of this embryo-maternal dialogue is crucial for a successful reproductive outcome. In the present study, we investigated the role of dendritic cells (DC) during implantation process using a transgenic mouse system (DTRtg) that allows transient depletion of CD11c+ cells in vivo through administration of diphtheria toxin. We observed that DC depletion impairs the implantation process, resulting in a reduced breeding efficiency. Furthermore, the maturity of uterine natural killer cells at dendritic cell knockout (DCKO) implantation sites was affected as well; as demonstrated by decreased perforin expression and reduced numbers of periodic-acid-Schiff (PAS)-positive cells. This was accompanied by disarrangements in decidual vascular development. In the present study, we were also able to identify a novel DC-dependent protein, phosphatidylinositol transfer protein beta (PITPbeta), involved in implantation and trophoblast development using a proteomic approach. Indeed, DCKO mice exhibited substantial anomalies in placental development, including hypocellularity of the spongiotrophoblast and labyrinthine layers and reduced numbers of trophoblast giant cells. Giant cells also down-regulated their expression of two characteristic markers of trophoblast differentiation, placental lactogen 1 and proliferin. In view of these findings, dendritic cells emerge as possible modulators in the orchestration of events leading to the establishment and maintenance of pregnancy.

  19. Missing upper incisors: a retrospective study of orthodontic space closure versus implant.

    Science.gov (United States)

    Jamilian, Abdolreza; Perillo, Letizia; Rosa, Marco

    2015-02-25

    The aim of this retrospective study was to compare the esthetic, periodontal, and functional outcomes of orthodontic space closure versus implant substitution in patients with missing maxillary incisors 5 years after completion of treatment. The study group consisted of ten patients treated with orthodontic space closure (six males, four females, mean age 19 ± 2.1 years at the completion of treatment) and ten patients treated with implant insertion (five males, five females, mean age 20 ± 1.4 years at the time of implant insertion). Tooth mobility, plaque index, probing depth, infraocclusion, open gingival embrasure (black triangle), and temporomandibular joint function were recorded at the 5.6 years follow-up. Self-perceived dental esthetic appearance was also evaluated through a visual analog scale (VAS) questionnaire. T-test was used to evaluate the data. All patients were equally satisfied with the appearance of their teeth 5.6 ± 0.4 years after the completion of treatment. No statistically significant differences were found in relation to the VAS scores of the subjects (P Orthodontic space closure and implant of missing maxillary incisors produced similar, well-accepted esthetic results. None of the treatments impaired temporomandibular joint function. Nevertheless, infraocclusion was evident in implant patients. Space closure patients also showed better periodontal health in comparison with implant patients.

  20. Treatment of an Erratic Extraction Socket for Implant Therapy in a Patient with Chronic Periodontitis.

    Science.gov (United States)

    Hamada, Yusuke; Prabhu, Srividya; John, Vanchit

    2016-01-01

    As implant therapy becomes more commonplace in daily practice, preservation and preparation of edentulous sites are key. Many times, however, implant therapy may not be considered at the time of tooth extraction and additional measures are not taken to conserve the edentulous site. While the healing process in extraction sockets has been well investigated and bone fill can be expected, there are cases where even when clinicians perform thorough debridement of the sockets, connective tissue infiltration into the socket can occur. This phenomenon, known as "erratic healing," may be associated with factors that lead to peri-implant disease and should be appropriately managed and treated prior to surgical implant placement. This case report describes the successful management of an erratic healing extraction socket in a 62-year-old Caucasian male patient with chronic periodontitis and the outcomes of an evidence-based treatment protocol performed prior to implant therapy. Careful preoperative analysis and cone beam computed tomography imaging can help detect signs of impaired healing in future implant sites and prevent surgical complications.

  1. Oral Implant-Prostheses: New Teeth for a Brighter Brain.

    Directory of Open Access Journals (Sweden)

    Vincenzo De Cicco

    Full Text Available Several studies have demonstrated that chewing can be regarded as a preventive measure for cognitive impairment, whereas masticatory deficiency, associated with soft-diet feeding, is a risk factor for the development of dementia. At present the link between orofacial sensorimotor activity and cognitive functions is unknown. In subjects with unilateral molar loss we have shown asymmetries in both pupil size and masticatory muscles electromyographic (EMG activity during clenching: the molar less side was characterized by a lower EMG activity and a smaller pupil. Since implant-prostheses, greatly reduced both the asymmetry in EMG activity and in pupil's size, trigeminal unbalance, leading to unbalance in the activity of the Locus Coeruleus (LC, may be responsible for the pupil's asymmetry. According to the findings obtained in animal models, we propose that the different activity of the right and left LC may induce an asymmetry in brain activity, thus leading to cognitive impairment. According to this hypothesis, prostheses improved the performance in a complex sensorimotor task and increased the mydriasis associated with haptic tasks. In conclusion, the present study indicates that the implant-prosthesis therapy, which reduces the unbalance of trigeminal proprioceptive afferents and the asymmetry in pupil's size, may improve arousal, boosting performance in a complex sensorimotor task.

  2. Rapid assessment of bilateral cochlear implantation for children in Kazakhstan.

    Science.gov (United States)

    Kosherbayeva, Lyazzat; Hailey, David; Kozhageldiyeva, Laura

    2014-10-01

    The aim of this study was to evaluate the effectiveness of bilateral cochlear implantation (CI) compared with unilateral CI for deaf children in the context of the Republic of Kazakhstan health system. Methods. A literature search was conducted, using the PubMed, Cochrane, and Embase data bases for studies that compared the effectiveness of bilateral and unilateral CI in children. The search included English language, publications from 2002-2012. Two reviewers independently evaluated all relevant studies. Administrative data relevant to CI in Kazakhstan were obtained from the Ministry of Health. Three relevant systematic reviews and an health technology assessment report were found. There was evidence of incremental benefits from bilateral CI but the quality of the available studies was poor and there was little information on longer term outcomes. No conclusions could be drawn regarding later incremental improvements to speech perception, learning, and quality of life. To date, in the Republic of Kazakhstan there is not full coverage of audiological screening due to the lack of medical equipment. This leads to late detection of hearing-impaired children and a long rehabilitation period, requiring more resources. Age of implantation in children is late and only a small minority attend general schools. The clinical effectiveness of bilateral CI, an expensive health technology, requires further study. Given the current situation in Kazakhstan with audiological screening and access to unilateral CI, there appeared to be other priorities for improving services for children with profound hearing impairment.

  3. Cochlear implantation in patient with Dandy-walker syndrome.

    Science.gov (United States)

    de Oliveira, Adriana Kosma Pires; Hamerschmidt, Rogerio; Mocelin, Marcos; Rezende, Rodrigo K

    2012-07-01

     Dandy Walker Syndrome is a congenital abnormality in the central nervous system, characterized by a deficiency in the development of middle cerebelar structures, cystic dilatation of the posterior pit communicating with the fourth ventricle and upward shift of the transverse sinuses, tentorium and dyes. Among the clinical signs are occipital protuberances, a progressive increase of the skull, bowing before the fontanels, papilledema, ataxia, gait disturbances, nystagmus, and intellectual impairment.  To describe a case of female patient, 13 years old with a diagnosis of this syndrome and bilateral hearing loss underwent cochlear implant surgery under local anesthesia and sedation.  CGS, 13 years old female was referred to the Otolaryngological Department of Otolaryngology Institute of Parana with a diagnosis of "Dandy-Walker syndrome" for Otolaryngological evaluation for bilateral hearing loss with no response to the use of hearing aids. Final Comments: The field of cochlear implants is growing rapidly. We believe that the presence of Dandy-Walker syndrome cannot be considered a contraindication to the performance of cochlear implant surgery, and there were no surgical complications due to neurological disorders with very favorable results for the patient who exhibits excellent discrimination. It has less need for lip reading with improvement in speech quality.

  4. Cochlear implantation in patient with Dandy-walker syndrome

    Directory of Open Access Journals (Sweden)

    Oliveira, Adriana Kosma Pires de

    2012-01-01

    Full Text Available Introduction: Dandy Walker Syndrome is a congenital abnormality in the central nervous system, characterized by a deficiency in the development of middle cerebelar structures, cystic dilatation of the posterior pit communicating with the fourth ventricle and upward shift of the transverse sinuses, tentorium and dyes. Among the clinical signs are occipital protuberances, a progressive increase of the skull, bowing before the fontanels, papilledema, ataxia, gait disturbances, nystagmus, and intellectual impairment. Objectives: To describe a case of female patient, 13 years old with a diagnosis of this syndrome and bilateral hearing loss underwent cochlear implant surgery under local anesthesia and sedation. Case Report: CGS, 13 years old female was referred to the Otolaryngological Department of Otolaryngology Institute of Parana with a diagnosis of "Dandy-Walker syndrome" for Otolaryngological evaluation for bilateral hearing loss with no response to the use of hearing aids. Final Comments: The field of cochlear implants is growing rapidly. We believe that the presence of Dandy-Walker syndrome cannot be considered a contraindication to the performance of cochlear implant surgery, and there were no surgical complications due to neurological disorders with very favorable results for the patient who exhibits excellent discrimination. It has less need for lip reading with improvement in speech quality.

  5. 20 CFR 220.184 - If the annuitant becomes disabled by another impairment(s).

    Science.gov (United States)

    2010-04-01

    ... impairment(s). 220.184 Section 220.184 Employees' Benefits RAILROAD RETIREMENT BOARD REGULATIONS UNDER THE... Activity or Medical Improvement § 220.184 If the annuitant becomes disabled by another impairment(s). If a new severe impairment(s) begins in or before the month in which the last impairment(s) ends, the Board...

  6. Cortical Plasticity after Cochlear Implantation

    DEFF Research Database (Denmark)

    Petersen, Bjørn; Gjedde, Albert; Wallentin, Mikkel

    2013-01-01

    recently implanted adult implant recipients listened to running speech or speech-like noise in four sequential PET sessions at each milestone. CI listeners with postlingual hearing loss showed differential activation of left superior temporal gyrus during speech and speech-like stimuli, unlike CI listeners...... with prelingual hearing loss. Furthermore, Broca's area was activated as an effect of time, but only in CI listeners with postlingual hearing loss. The study demonstrates that adaptation to the cochlear implant is highly related to the history of hearing loss. Speech processing in patients whose hearing loss...... occurred after the acquisition of language involves brain areas associated with speech comprehension, which is not the case for patients whose hearing loss occurred before the acquisition of language. Finally, the findings confirm the key role of Broca's area in restoration of speech perception, but only...

  7. Tinting of intraocular lens implants

    Energy Technology Data Exchange (ETDEWEB)

    Zigman, S.

    1982-06-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users.

  8. MRI of orbital hydroxyapatite implants

    International Nuclear Information System (INIS)

    Flanders, A.E.; De Potter P.; Rao, V.M.; Tom, B.M.; Shields, C.L.; Shields, J.A.

    1996-01-01

    Our aim was to use MRI for the postsurgical assessment of a new form of integrated orbital implant composed of a porous calcium phosphate hydroxyapatite substrate. We studied ten patients 24-74 years of age who underwent enucleation and implantation of a hydroxyapatite ball; 5-13 months after surgery, each patient was examined by spin-echo MRI, with fat suppression and gadolinium enhancement. Fibrovascular ingrowth was demonstrated in all ten patients as areas of enhancement at the periphery of the hydroxyapatite sphere that extended to the center to a variable degree. The radiologist should aware of the MRI appearances of the coralline hydroxyapatite orbital implant since it is now widely used following enucleation. MRI is a useful means to determine successful incorporation of the substrate into the orbital tissues. The normal pattern of contrast enhancement should not be mistaken for recurrent tumor or infection. (orig.)

  9. Tinting of intraocular lens implants

    International Nuclear Information System (INIS)

    Zigman, S.

    1982-01-01

    Intraocular lens (IOL) implants of polymethyl methacrylate (PMMA) lack an important yellow pigment useful as a filter in the visual process and in the protection of the retina from short-wavelength radiant energy. The ability to produce a yellow pigment in the PMMA used in IOL implants by exposure to near-ultraviolet (UV) light was tested. It was found that the highly cross-linked material in Copeland lens blanks was tinted slightly because of this exposure. The absorptive properties of lens blanks treated with near-UV light in this way approached that of the absorptive properties of human lenses. This finding shows that it is possible to alter IOL implants simply so as to induce a pale-yellow pigment in them to improve the visual process and to protect the retinas of IOL users

  10. Implant rehabilitation in bruxism patient

    Science.gov (United States)

    Goiato, Marcelo Coelho; Sonego, Mariana Vilela; dos Santos, Daniela Micheline; da Silva, Emily Vivianne Freitas

    2014-01-01

    A white female patient presented to the university clinic to obtain implant retained prostheses. She had an edentulous maxillary jaw and presented three teeth with poor prognosis (33, 34 and 43). The alveolar bone and the surrounding tissues were healthy. The patient did not report any relevant medical history contraindicating routine dental treatment or implant surgery, but self-reported a dental history of asymptomatic nocturnal bruxism. The treatment plan was set and two Branemark protocols supported by six implants in each arch were installed after a 6-month healing period. A soft occlusal splint was made due to the patient's history of bruxism, and the lack of its use by the patient resulted in an acrylic fracture. The prosthesis was repaired and the importance of using the occlusal splint was restated. In the 4-year follow-up no fractures were reported. PMID:24907215

  11. MR imaging of breast implants.

    Science.gov (United States)

    Gorczyca, D P

    1994-11-01

    MR imaging has proved to be an excellent imaging modality in locating free silicone and evaluating an implant for rupture, with a sensitivity of approximately 94% and specificity of 97%. Silicone has a unique MR resonance frequency and long T1 and T2 relaxation times, which allows several MR sequences to provide excellent diagnostic images. The most commonly used sequences include T2-weighted, STIR, and chemical shift imaging (Figs. 3, 13, and 14). The T2-weighted and STIR sequences are often used in conjunction with chemical water suppression. The most reliable findings on MR images for detection of implant rupture include identification of the collapsed implant shell (linguine sign) and free silicone within the breast parenchyma.

  12. Cognitive impairments in epilepsy

    Directory of Open Access Journals (Sweden)

    Aleksandr Anatolyevich Kostylev

    2013-01-01

    Full Text Available Cognitive impairments in epilepsy are a current problem in neurology. The basis of the idea on the pathogenesis of higher nervous system dysfunctions is the interaction of a few factors that include the form and duration of the disease, gender differences, and the impact of antiepileptic therapy. The role of interattack epileptiform changes in the development of cognitive deficit in adults and epileptic encephalopathies in children is discussed. Up-to-date neurophysiological and neuroimaging diagnostic methods allow the detection of new features in the course and progression of higher nervous system dysfunctions in epilepsy.

  13. Cognitive impairment and pragmatics.

    Science.gov (United States)

    Gutiérrez-Rexach, Javier; Schatz, Sara

    2016-01-01

    One of the most important ingredients of felicitous conversation exchanges is the adequate expression of illocutionary force and the achievement of perlocutionary effects, which can be considered essential to the functioning of pragmatic competence. The breakdown of illocutionary and perlocutionary functions is one of the most prominent external features of cognitive impairment in Alzheimer's Disease, with devastating psychological and social consequences for patients, their family and caregivers. The study of pragmatic functions is essential for a proper understanding of the linguistic and communicative aspects of Alzheimer's disease.

  14. Surface engineering by ion implantation

    International Nuclear Information System (INIS)

    Nielsen, Bjarne Roger

    1995-01-01

    Awidespread commercial applica tion iof particle accelerators is for ion implantation. Accelerator beams are used for ion implantation into metals, alloying a thin surface layer with foreign atoms to concentrations impossible to achieve by thermal processes, making for dramatic improvements in hardness and in resistance to wear and corrosion. Traditional hardening processes require high temperatures causing deformation; ion implantation on the other hand is a ''cold process'', treating the finished product. The ionimplanted layer is integrated in the substrate, avoiding the risk of cracking and delamination from normal coating processes. Surface properties may be ''engineered'' independently of those of the bulk material; the process does not use environmentally hazardous materials such as chromium in the surface coating. The typical implantation dose required for the optimum surface properties of metals is around 2 x 10 17 ion/cm 2 , a hundred times the typical doses for semiconductor processing. When surface areas of more than a few square centimetres have to be treated, the implanter must therefore be able to produce high beam currents (5 to 10 mA) to obtain an acceptable treatment time. Ion species used include nitrogen, boron, carbon, titanium, chromium and tantalum, and beam energies range from 50 to 200 keV. Since most components are three dimensional, it must be possible to rotate and tilt them in the beam, and control beam position over a large area. Examples of industrial applications are: - surface treatment of prostheses (hip and knee joints) to reduce wear of the moving parts, using biocompatible materials; - ion implantation into high speed ball bearings to protect against the aqueous corrosion in jet engines (important for service helicopters on oil rigs); - hardening of metal forming and cutting tools; - reduction of corrosive wear of plastic moulding tools, which are expensive to produce

  15. Carbon Fiber Biocompatibility for Implants

    Directory of Open Access Journals (Sweden)

    Richard Petersen

    2016-01-01

    Full Text Available Carbon fibers have multiple potential advantages in developing high-strength biomaterials with a density close to bone for better stress transfer and electrical properties that enhance tissue formation. As a breakthrough example in biomaterials, a 1.5 mm diameter bisphenol-epoxy/carbon-fiber-reinforced composite rod was compared for two weeks in a rat tibia model with a similar 1.5 mm diameter titanium-6-4 alloy screw manufactured to retain bone implants. Results showed that carbon-fiber-reinforced composite stimulated osseointegration inside the tibia bone marrow measured as percent bone area (PBA to a great extent when compared to the titanium-6-4 alloy at statistically significant levels. PBA increased significantly with the carbon-fiber composite over the titanium-6-4 alloy for distances from the implant surfaces of 0.1 mm at 77.7% vs. 19.3% (p < 10−8 and 0.8 mm at 41.6% vs. 19.5% (p < 10−4, respectively. The review focuses on carbon fiber properties that increased PBA for enhanced implant osseointegration. Carbon fibers acting as polymer coated electrically conducting micro-biocircuits appear to provide a biocompatible semi-antioxidant property to remove damaging electron free radicals from the surrounding implant surface. Further, carbon fibers by removing excess electrons produced from the cellular mitochondrial electron transport chain during periods of hypoxia perhaps stimulate bone cell recruitment by free-radical chemotactic influences. In addition, well-studied bioorganic cell actin carbon fiber growth would appear to interface in close contact with the carbon-fiber-reinforced composite implant. Resulting subsequent actin carbon fiber/implant carbon fiber contacts then could help in discharging the electron biological overloads through electrochemical gradients to lower negative charges and lower concentration.

  16. The perception of stress pattern in young cochlear implanted children: an EEG study

    Directory of Open Access Journals (Sweden)

    Niki Katerina Vavatzanidis

    2016-03-01

    Full Text Available Children with sensorineural hearing loss may (regain hearing with a cochlear implant – a device that transforms sounds into electric pulses and bypasses the dysfunctioning inner ear by stimulating the auditory nerve directly with an electrode array. Many implanted children master the acquisition of spoken language successfully, yet we still have little knowledge of the actual input they receive with the implant and specifically which language sensitive cues they hear. This would be important however, both for understanding the flexibility of the auditory system when presented with stimuli after a (life-long phase of deprivation and for planning therapeutic intervention. In rhythmic languages the general stress pattern conveys important information about word boundaries. Infant language acquisition relies on such cues and can be severely hampered when this information is missing, as seen for dyslexic children and children with specific language impairment. Here we ask whether children with a cochlear implant perceive differences in stress patterns during their language acquisition phase and if they do, whether it is present directly following implant stimulation or if and how much time is needed for the auditory system to adapt to the new sensory modality. We performed a longitudinal ERP study, testing in bimonthly intervals the stress pattern perception of 17 young hearing impaired children (age range: 9-50 months; mean: 22 months during their first 6 months of implant use. An additional session before the implantation served as control baseline. During a session they passively listened to an oddball paradigm featuring the disyllable baba, which was stressed either on the first or second syllable (trochaic vs. iambic stress pattern. A group of age-matched normal hearing children participated as controls.Our results show, that within the first 6 months of implant use the implanted children develop a negative mismatch response for iambic but not

  17. The Perception of Stress Pattern in Young Cochlear Implanted Children: An EEG Study.

    Science.gov (United States)

    Vavatzanidis, Niki K; Mürbe, Dirk; Friederici, Angela D; Hahne, Anja

    2016-01-01

    Children with sensorineural hearing loss may (re)gain hearing with a cochlear implant-a device that transforms sounds into electric pulses and bypasses the dysfunctioning inner ear by stimulating the auditory nerve directly with an electrode array. Many implanted children master the acquisition of spoken language successfully, yet we still have little knowledge of the actual input they receive with the implant and specifically which language sensitive cues they hear. This would be important however, both for understanding the flexibility of the auditory system when presented with stimuli after a (life-) long phase of deprivation and for planning therapeutic intervention. In rhythmic languages the general stress pattern conveys important information about word boundaries. Infant language acquisition relies on such cues and can be severely hampered when this information is missing, as seen for dyslexic children and children with specific language impairment. Here we ask whether children with a cochlear implant perceive differences in stress patterns during their language acquisition phase and if they do, whether it is present directly following implant stimulation or if and how much time is needed for the auditory system to adapt to the new sensory modality. We performed a longitudinal ERP study, testing in bimonthly intervals the stress pattern perception of 17 young hearing impaired children (age range: 9-50 months; mean: 22 months) during their first 6 months of implant use. An additional session before the implantation served as control baseline. During a session they passively listened to an oddball paradigm featuring the disyllable "baba," which was stressed either on the first or second syllable (trochaic vs. iambic stress pattern). A group of age-matched normal hearing children participated as controls. Our results show, that within the first 6 months of implant use the implanted children develop a negative mismatch response for iambic but not for trochaic

  18. Percutaneous closure of paravalvular leaks after transcatheter aortic valve implantation with Edwards SAPIEN prosthesis: a report of two cases.

    Science.gov (United States)

    Estévez-Loureiro, Rodrigo; Salgado-Fernández, Jorge; Vázquez-González, Nicolás

    2013-02-01

    Significant periprosthetic aortic regurgitation after transcatheter aortic valve implantation with Edwards SAPIEN prosthesis has become a major concern of this technique given its association with impaired survival. We report the successful closure of such defects using vascular occlusion devices with significant improvement in clinical status of patients.

  19. Neutrophil Responses to Sterile Implant Materials.

    Directory of Open Access Journals (Sweden)

    Siddharth Jhunjhunwala

    Full Text Available In vivo implantation of sterile materials and devices results in a foreign body immune response leading to fibrosis of implanted material. Neutrophils, one of the first immune cells to be recruited to implantation sites, have been suggested to contribute to the establishment of the inflammatory microenvironment that initiates the fibrotic response. However, the precise numbers and roles of neutrophils in response to implanted devices remains unclear. Using a mouse model of peritoneal microcapsule implantation, we show 30-500 fold increased neutrophil presence in the peritoneal exudates in response to implants. We demonstrate that these neutrophils secrete increased amounts of a variety of inflammatory cytokines and chemokines. Further, we observe that they participate in the foreign body response through the formation of neutrophil extracellular traps (NETs on implant surfaces. Our results provide new insight into neutrophil function during a foreign body response to peritoneal implants which has implications for the development of biologically compatible medical devices.

  20. Fractographic analysis of fractured dental implant components

    Directory of Open Access Journals (Sweden)

    Chih-Ling Chang

    2013-03-01

    Conclusion: To avoid implant fracture, certain underlying mechanical risk factors should be noted such as patients with a habit of bruxism, bridgework with a cantilever design, or two implants installed in a line in the posterior mandible.

  1. Production of amorphous alloys by ion implantation

    International Nuclear Information System (INIS)

    Grant, W.A.; Chadderton, L.T.; Johnson, E.

    1978-01-01

    Recent data are reported on the use of ion implantation to produce amorphous metallic alloys. In particular data on the dose dependence of the crystalline to amorphous transition induced by P + implantation of nickel is presented. (Auth.)

  2. Dental implant surgery: planning and guidance

    International Nuclear Information System (INIS)

    Lobregt, S.; Schillings, J.J.; Vuurberg, E.

    2001-01-01

    A prototype application has been developed for interactive planning of dental implants on the EasyVision workstation. The user is led step by step via virtual positioning of the implant to the design of a customized drill guide. (orig.)

  3. Preparation of targets by ion implantation

    International Nuclear Information System (INIS)

    Santry, D.C.

    1976-01-01

    Various factors are described which are involved in target preparation by direct ion implantation and the limitations and pitfalls of the method are emphasized. Examples are given of experiments for which ion implanted targets are well suited. (author)

  4. Surgical Templates for Dental Implant Positioning; Current ...

    African Journals Online (AJOL)

    prosthodontics; however, designing an implant‑supported prosthesis with function .... template where a provisional fixed restoration bridges the implant site. Pesun and ... in single implant therapy or short‑span implant‑supported prostheses.

  5. Influence of Hot Implantation on Residual Radiation Damage in Silicon Carbide

    International Nuclear Information System (INIS)

    Rawski, M.; Zuk, J.; Kulik, M.; Drozdziel, A.; Pyszniak, K.; Turek, M.; Lin, L.; Prucnal, S.

    2011-01-01

    Remarkable thermomechanical and electrical properties of silicon carbide (SiC) make this material very attractive for high-temperature, high-power, and high-frequency applications. Because of very low values of diffusion coefficient of most impurities in SiC, ion implantation is the best method to selectively introduce dopants over well-defined depths in SiC. Aluminium is commonly used for creating p-type regions in SiC. However, post-implantation radiation damage, which strongly deteriorates required electric properties of the implanted layers, is difficult to anneal even at high temperatures because of remaining residual damage. Therefore implantation at elevated target temperatures (hot implantation) is nowadays an accepted method to decrease the level of the residual radiation damage by avoiding ion beam-induced amorphization. The main objective of this study is to compare the results of the Rutherford backscattering spectroscopy with channeling and micro-Raman spectroscopy investigations of room temperature and 500 o C Al + ion implantation-induced damage in 6H-SiC and its removal by high temperature (up to 1600 o C) thermal annealing. (author)

  6. Surface layers in the 4A group metals with implanted silicon ions

    International Nuclear Information System (INIS)

    Kovneristyj, Yu.K.; Vavilova, V.V.; Krasnopevtsev, V.V.; Galkin, L.N.; Kudyshev, A.N.; Klechkovskaya, V.V.

    1987-01-01

    A study was made on the change of structure and phase composition of fine near the surface layers of 4A group metals (Hf, Zr, Ti) during ion Si implantation and successive thermal annealing at elevated temperatures. Implantation of Si + ions with 30 or 16 keV energy in Ti, Zr and Hf at room temperature results to amorphization of metal surface layer. The surface hafnium and titanium layer with implanted Si atoms due to interaction with residual atmosphere of oxygen turns during annealing at 870 K to amorphous solid solution of HfO 2m or TiO 2 with Si, preventing further metal oxidation; layers of amorphous alloy are characterized by thermal stability up to 1270 K. Oxidation of the surface amorphous layer in residual oxygen atmosphere and its crystallization in ZrO 2 take place in result of Zr annealing with implanted Si ions at temperature not exceeding 870 K. Similar phenomena are observed in the case of hafnium with implanted oxygen ions or small dose of silicon ions. Thermal stability of amorphous layers produced during ion implantation of Si in Ti, Zr and Hf corresponds to scale resistance of monolithic alloys in Ti-Si, Zr-Si and Hf-Si systems

  7. Using optical coherence tomography to evaluate glaucoma implant healing response in rabbit eyes

    Science.gov (United States)

    Gossage, Kirk W.; Tkaczyk, Tomasz S.; Barton, Jennifer K.

    2002-06-01

    Glaucoma is a set of diseases that cause optic nerve damage and visual field loss. The most important risk factor for the development of glaucoma is elevated intraocular pressure. One approach used to alleviate the pressure increase is to surgically install glaucoma implants. Two standard Ahmed and ten experimental ePTFE implants were evaluated in this study in rabbit eyes. The implants were imaged with optical coherence tomography (OCT) at 0, 7, 15, 30, and 90 days after implantation. Histology was collected at days 7, 15, 30, and 90 and compared to the OCT images. Preliminary analysis of images indicates that OCT can visualize the development of fibrous encapsulation of the implant, tissue erosion, fibrin accumulation in the implant tube, and tube position in the anterior chamber. A new OCT handheld probe was developed to facilitate in vivo imaging in rabbit eye studies. The OCT probe consists of a mechanical scaffold designed to allow the imaging fiber to be held in a fixed position with respect to the rabbit eye, with minimal anesthesia. A piezo electric lateral scanning device allows the imaging fiber to be scanned across the tissue so that 2D images may be acquired.

  8. Doping β-Ga2O3 with europium: influence of the implantation and annealing temperature

    Science.gov (United States)

    Peres, M.; Lorenz, K.; Alves, E.; Nogales, E.; Méndez, B.; Biquard, X.; Daudin, B.; Víllora, E. G.; Shimamura, K.

    2017-08-01

    β-Ga2O3 bulk single crystals were doped by ion implantation at temperatures from room temperature to 1000 °C, using a 300 keV Europium beam with a fluence of 1  ×  1015 at cm-2. Rising the implantation temperature from room temperature to 400-600 °C resulted in a significant increase of the substitutional Eu fraction and of the number of Eu ions in the 3+  charge state as well as in a considerable decrease of implantation damage. Eu is found in both charge states 2+  and 3+  and their relative fractions are critically dependent on the implantation and annealing temperature, suggesting that defects play an important role in stabilizing one of the charge states. The damage recovery during post-implant annealing is a complex process and typically defect levels first increase for intermediate annealing temperatures and a significant recovery of the crystal only starts around 1000 °C. Cathodoluminescence spectra are dominated by the sharp Eu3+ related intra-ionic 4f transition lines in the red spectral region. They show a strong increase of the emission intensity with increasing annealing temperature, in particular for samples implanted at elevated temperature, indicating the optical activation of Eu3+ ions. However, no direct correlation of emission intensity and Eu3+ fraction was found, again pointing to the important role of defects on the physical properties of these luminescent materials.

  9. Insulin protects against Aβ-induced spatial memory impairment, hippocampal apoptosis and MAPKs signaling disruption.

    Science.gov (United States)

    Ghasemi, Rasoul; Zarifkar, Asadollah; Rastegar, Karim; maghsoudi, Nader; Moosavi, Maryam

    2014-10-01

    Alzheimer disease (AD) is a progressive neurodegenerative disease characterized by extracellular deposits of beta amyloid (Aβ) and neuronal loss particularly in the hippocampus. Accumulating evidences have implied that insulin signaling impairment plays a key role in the pathology of AD; as much as it is considered as type 3 Diabetes. MAPKs are a group of signaling molecules which are involved in pathobiology of AD. Therefore this study was designed to investigate if intrahippocampal insulin hinders Aβ-related memory deterioration, hippocampal apoptosis and MAPKs signaling alteration induced by Aβ. Adult male Sprague-Dawely rats weighing 250-300 g were used in this study. The canules were implanted bilaterally into CA1 region. Aβ25-35 was administered during first 4 days after surgery (5 μg/2.5 μL/daily). Insulin treatment (0.5 or 6 mU) was done during days 4-9. The animal's learning and memory capability was assessed on days 10-13 using Morris water maze. After finishing of behavioral studies the hippocampi was isolated and the amount of hippocampal cleaved caspase 3 (the landmark of apoptosis) and the phosphorylated (activated) forms of P38, JNK and ERK was analyzed by western blot. The results showed that insulin in 6 but not 0.5 mU reversed the memory loss induced by Aβ25-35. Western blot analysis revealed that Aβ25-35 induced elevation of caspase-3 and all 3 MAPks subfamily activity, while insulin in 6 mu restored ERK and P38 activation but has no effect on JNK. This study disclosed that intrahippocampal insulin treatment averts not only Aβ-induced memory deterioration but also hippocampal caspase-3, ERK and P38 activation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Implants in free fibula flap supporting dental rehabilitation - Implant and peri-implant related outcomes of a randomized clinical trial.

    Science.gov (United States)

    Kumar, Vinay V; Ebenezer, Supriya; Kämmerer, Peer W; Jacob, P C; Kuriakose, Moni A; Hedne, Naveen; Wagner, Wilfried; Al-Nawas, Bilal

    2016-11-01

    The objective of this study was to assess the difference in success rates of implants when using two or four implant-supported-overdentures following segmental mandibular reconstruction with fibula free flap. This prospective, parallel designed, randomized clinical study was conducted with 1:1 ratio. At baseline, all participants already had segmental reconstruction of mandible with free fibula flap. The participants were randomized into two groups: Group-I received implant-supported-overdentures on two tissue-level implants and Group-II received implant-supported-overdentures on four tissue-level implants. Success rates of the implants were evaluated at 3 months, 6 months and 12 months following implant loading using marginal bone level changes as well as peri-implant indices (Buser et al., 1990). 52 patients were randomized into two treatment groups (26 each), out of which 18 patients (36 implants) of Group-I and 17 patients (68 implants) of Group-II were evaluated. One implant in Group-I was lost due to infective complications and one patient in the same group had superior barrel necrosis. There was a statistically significant increase at both time points (p = 0.03, p = 0.04 at 6 months, 12 months) in the amount of marginal bone loss in Group-I (0.4 mm, 0.5 mm at 6 months, 12 months) as compared to Group-II (0.1 mm, 0.2 mm at 6 months, 12 months). There were no clinically significant changes peri-implant parameters between both groups. Peri-implant soft tissue hyperplasia was seen in both groups, 32% of implants at 3-months, 26% at 6-months and 3% at 12-months follow-up. The results of this study show that patients with 2-implant-supported-overdentures had higher marginal bone loss as compared to patients with 4-implant-supported-overdentures. There were no clinically significant differences in peri-implant soft tissue factors in patients with 2- or 4-implant-supported-overdentures. Hyperplastic peri-implant tissues are common in the early implant

  11. Implant surface preparation in the surgical treatment of experimental peri-implantitis with autogenous bone graft and ePTFE membrane in cynomolgus monkeys

    DEFF Research Database (Denmark)

    Schou, Søren; Holmstrup, Palle; Jørgensen, Torben

    2003-01-01

    peri-implantitis; treatment; implant surface preparation; nonhuman primates; histology; stereology......peri-implantitis; treatment; implant surface preparation; nonhuman primates; histology; stereology...

  12. Impact of cone-beam computed tomography on implant planning and on prediction of implant size

    Energy Technology Data Exchange (ETDEWEB)

    Pedroso, Ludmila Assuncao de Mello; Silva, Maria Alves Garcia Santos, E-mail: ludmilapedroso@hotmail.com [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Fac. de Odontologia; Garcia, Robson Rodrigues [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Fac. de Odontologia. Dept. de Medicina Oral; Leles, Jose Luiz Rodrigues [Universidade Paulista (UNIP), Goiania, GO (Brazil). Fac. de Odontologia. Dept. de Cirurgia; Leles, Claudio Rodrigues [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Fac. de Odontologia. Dept. de Prevencao e Reabilitacao Oral

    2013-11-15

    The aim was to investigate the impact of cone-beam computed tomography (CBCT) on implant planning and on prediction of final implant size. Consecutive patients referred for implant treatment were submitted to clinical examination, panoramic (PAN) radiography and a CBCT exam. Initial planning of implant length and width was assessed based on clinical and PAN exams, and final planning, on CBCT exam to complement diagnosis. The actual dimensions of the implants placed during surgery were compared with those obtained during initial and final planning, using the McNemmar test (p < 0.05). The final sample comprised 95 implants in 27 patients, distributed over the maxilla and mandible. Agreement in implant length was 50.5% between initial and final planning, and correct prediction of the actual implant length was 40.0% and 69.5%, using PAN and CBCT exams, respectively. Agreement in implant width assessment ranged from 69.5% to 73.7%. A paired comparison of the frequency of changes between initial or final planning and implant placement (McNemmar test) showed greater frequency of changes in initial planning for implant length (p < 0.001), but not for implant width (p = 0.850). The frequency of changes was not influenced by implant location at any stage of implant planning (chi-square test, p > 0.05). It was concluded that CBCT improves the ability of predicting the actual implant length and reduces inaccuracy in surgical dental implant planning. (author)

  13. Implantable Cardiac Pacemakers – 50 Years from the First Implantation

    Directory of Open Access Journals (Sweden)

    Ratko Magjarević

    2010-01-01

    Overview: Development of implantable cardiac pacemaker was enabled by another important invention, the silicon transistor. h ough the invention of suitable lithium cells as appropriate power supply was essential for prolongation of battery life cycle and for increased reliability of pacemakers, main milestones in the development were associated with technological breakthroughs in electronics: from transistors, which introduced such features as small size and low power consumption, to hybrid and integrated circuits, which enabled programmability, microprocessors, which added more options in programming (multiprogrammability, diagnostics and telemetry, and the ICT (information communication technology that enabled physicians remote access to patients and interrogation of their implantable devices. Conclusions: Implantable pacemakers are reliable devices indicated for a wide range of dif erent therapies of cardiac rhythm disorders and heart failure. h ere is still a lot to learn about the physiology of a normal heart and even more about the failing heart. Modern pacemakers provide physicians valuable information from pacemakers’ memory via the built-in telemetry system. h ese information help physicians to better understand pathologic processes within the heart, thus contributing to the development of new ideas for treatment of diseases and for precise tailoring of the therapy to the patient’s needs. Although implantable pacemakers have reached the level of mature technology, they will continue to develop with therapies and diagnostics to facilitate a higher quality of life.

  14. Fertility impairment in radiotherapy

    Directory of Open Access Journals (Sweden)

    Marta Biedka

    2016-02-01

    Full Text Available Infertility as a result of antineoplastic therapy is becoming a very important issue due to the growing incidence of neoplastic diseases. Routinely applied antineoplastic treatments and the illness itself lead to fertility disorders. Therapeutic methods used in antineoplastic treatment may cause fertility impairment or sterilization due to permanent damage to reproductive cells. The risk of sterilization depends on the patient’s sex, age during therapy, type of neoplasm, radiation dose and treatment area. It is known that chemotherapy and radiotherapy can lead to fertility impairment and the combination of these two gives an additive effect. The aim of this article is to raise the issue of infertility in these patients. It is of growing importance due to the increase in the number of children and young adults who underwent radiotherapy in the past. The progress in antineoplastic therapy improves treatment results, but at the same time requires a deeper look at existential needs of the patient. Reproductive function is an integral element of self-esteem and should be taken into account during therapy planning.

  15. Mechanism for elevated temperature leaching

    International Nuclear Information System (INIS)

    Kenna, B.T.; Murphy, K.D.

    1979-01-01

    Long-term, elevated temperature leaching and subsequent electron microprobe analysis of simulated waste glass and ceramic materials have been completed. A cyclic leaching pattern was found in all systems over a 20-month period. It appears that the leaching of mobile ions by simple diffusional processes is modified by more complex chemical interactions. The release of immobile ions is primarily a function of their chemical interactions in the matrix which suggests that these ions may be complex species when released into solution. A mechanism is proposed which incorporates these ideas and the cyclic phenomenon observed

  16. PLC VVVF Elevator Control System

    OpenAIRE

    Tang, Yujian; Gui, Tianyu

    2016-01-01

    The aim of the thesis is to introduce the PLC VVVF elevator and its control system. The thesis can be divided into three parts. The first part is about the overview of the lift: the kinds of the lift and the structure of the lift, it shows the knowledge about the components and the operating systems of the lift. The second part is about the PLC control system, it’s about the operations of the lift from the introduction about the hardware and software of the PLC control system. And the thi...

  17. Augmentation Mammaplasty Using Implants: A Review

    Directory of Open Access Journals (Sweden)

    Susumu Takayanagi

    2012-09-01

    Full Text Available One of the techniques for augmentation mammaplasty is the procedure using implants. Even though this technique has been used for many years, there are still several controversial issues to be discussed and overcome for patient safety. In this review article, capsular contracture, leak or rupture of the implants, possible systemic disease, relation with breast cancer, and recent problems with Poly Implant Prothese implants are described and discussed.

  18. Augmentation Mammaplasty Using Implants: A Review

    Directory of Open Access Journals (Sweden)

    Susumu Takayanagi

    2012-09-01

    Full Text Available One of the techniques for augmentation mammaplasty is the procedure using implants. Eventhough this technique has been used for many years, there are still several controversial issuesto be discussed and overcome for patient safety. In this review article, capsular contracture,leak or rupture of the implants, possible systemic disease, relation with breast cancer, andrecent problems with Poly Implant Prothese implants are described and discussed.

  19. Plasma immersion ion implantation into insulating materials

    International Nuclear Information System (INIS)

    Tian Xiubo; Yang Shiqin

    2006-01-01

    Plasma immersion ion implantation (PIII) is an effective surface modification tool. During PIII processes, the objects to be treated are immersed in plasmas and then biased to negative potential. Consequently the plasma sheath forms and ion implantation may be performed. The pre-requirement of plasma implantation is that the object is conductive. So it seems difficult to treat the insulating materials. The paper focuses on the possibilities of plasma implantation into insulting materials and presents some examples. (authors)

  20. Influence of different implant materials on the primary stability of orthodontic mini-implants

    OpenAIRE

    Chin-Yun Pan; Szu-Ting Chou; Yu-Chuan Tseng; Yi-Hsin Yang; Chao-Yi Wu; Ting-Hsun Lan; Pao-Hsin Liu; Hong-Po Chang

    2012-01-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants w...