WorldWideScience

Sample records for element comparative analysis

  1. PHARMACOPOEIA METHODS FOR ELEMENTAL ANALYSIS OF MEDICINES: A COMPARATIVE STUDY

    Directory of Open Access Journals (Sweden)

    Tetiana M. Derkach

    2018-01-01

    Full Text Available The article is devoted to the problem of quality assurance of medicinal products, namely the determination of elemental impurity concentration compared to permitted daily exposures for and the correct choice analytical methods that are adequate to the formulated tasks. The paper goal is to compare characteristics of four analytical methods recommended by the Pharmacopoeia of various countries to control the content of elemental impurities in medicines, including medicinal plant raw materials and herbal medicines. Both advantages and disadvantages were described for atomic absorption spectroscopy with various atomising techniques, as well as atomic emission spectroscopy and mass spectrometry with inductively coupled plasma. The choice of the most rational analysis method depends on a research task and is reasoned from the viewpoint of analytical objectives, possible complications, performance attributes, and economic considerations. The methods of ICP-MS and GFAAS were shown to provide the greatest potential for determining the low and ultra-low concentrations of chemical elements in medicinal plants and herbal medicinal products. The other two methods, FAAS and ICP-AES, are limited to the analysis of the main essential elements and the largest impurities. The ICP-MS is the most efficient method for determining ultra-low concentrations. However, the interference of mass peaks is typical for ICP-MS. It is formed not only by impurities but also by polyatomic ions with the participation of argon, as well as atoms of gases from the air (C, N and O or matrices (O, N, H, P, S and Cl. Therefore, a correct sample preparation, which guarantees minimisation of impurity contamination and loss of analytes becomes the most crucial stage of analytical applications of ICP-MS. The detections limits for some chemical elements, which content is regulated in modern Pharmacopoeia, were estimated for each method and analysis conditions of medicinal plant raw

  2. Thermal buckling comparative analysis using Different FE (Finite Element) tools

    Energy Technology Data Exchange (ETDEWEB)

    Banasiak, Waldemar; Labouriau, Pedro [INTECSEA do Brasil, Rio de Janeiro, RJ (Brazil); Burnett, Christopher [INTECSEA UK, Surrey (United Kingdom); Falepin, Hendrik [Fugro Engineers SA/NV, Brussels (Belgium)

    2009-12-19

    High operational temperature and pressure in offshore pipelines may lead to unexpected lateral movements, sometimes call lateral buckling, which can have serious consequences for the integrity of the pipeline. The phenomenon of lateral buckling in offshore pipelines needs to be analysed in the design phase using FEM. The analysis should take into account many parameters, including operational temperature and pressure, fluid characteristic, seabed profile, soil parameters, coatings of the pipe, free spans etc. The buckling initiation force is sensitive to small changes of any initial geometric out-of-straightness, thus the modeling of the as-laid state of the pipeline is an important part of the design process. Recently some dedicated finite elements programs have been created making modeling of the offshore environment more convenient that has been the case with the use of general purpose finite element software. The present paper aims to compare thermal buckling analysis of sub sea pipeline performed using different finite elements tools, i.e. general purpose programs (ANSYS, ABAQUS) and dedicated software (SAGE Profile 3D) for a single pipeline resting on an the seabed. The analyses considered the pipeline resting on a flat seabed with a small levels of out-of straightness initiating the lateral buckling. The results show the quite good agreement of results of buckling in elastic range and in the conclusions next comparative analyses with sensitivity cases are recommended. (author)

  3. Comparative analysis of regulatory elements in different germin-like ...

    African Journals Online (AJOL)

    It was observed that these promoters have important regulatory elements, which are involved in various important functions. These elements have been compared on the basis of location, copy number, and distributed on positive and negative strands. It was also observed that some of these elements are common and ...

  4. A comparative phylogenetic analysis of full-length mariner elements

    Indian Academy of Sciences (India)

    Mariner like elements (MLEs) are widely distributed type II transposons with an open reading frame (ORF) for transposase. We studied comparative phylogenetic evolution and inverted terminal repeat (ITR) conservation of MLEs from Indian saturniid silkmoth, Antheraea mylitta with other full length MLEs submitted in the ...

  5. Comparative analysis of vitamin C, crude protein, elemental nitrogen ...

    African Journals Online (AJOL)

    Yomi

    2011-12-21

    Dec 21, 2011 ... greens (Brassica napus L.) and kale (Brassica oleracea var. acephala) ... Nitrogen is essential for protein production, for proper growth of ... Brassica crops. ..... the effect of trace element-amended fertilizers on their Co, Se, and.

  6. A Comparative Analysis of Nutrients and Mineral Elements Content ...

    African Journals Online (AJOL)

    (Mg), Iron (Fe), Copper (Cu) and Zinc (Zn) content, while P. pedicellatum has high ... INTRODUCTION ... central to animal production and productivity. .... for growth and serve as structural element in all plant ... the animal's body, it ensured correct maintenance of ... Ash content because Ash is the approximation of total.

  7. Comparative analysis of regulatory elements in different germin-like ...

    African Journals Online (AJOL)

    STORAGESEVER

    INTRODUCTION. Germin and germin-like proteins (GLPs) is a member of ..... analysis of germin-like protein gene 2 promoter from Oryza sativa L. ssp. Indica. ... esculenta Crantz) root proteome: Protein identification and differential expression.

  8. Identification of conserved regulatory elements by comparative genome analysis

    Directory of Open Access Journals (Sweden)

    Jareborg Niclas

    2003-05-01

    Full Text Available Abstract Background For genes that have been successfully delineated within the human genome sequence, most regulatory sequences remain to be elucidated. The annotation and interpretation process requires additional data resources and significant improvements in computational methods for the detection of regulatory regions. One approach of growing popularity is based on the preferential conservation of functional sequences over the course of evolution by selective pressure, termed 'phylogenetic footprinting'. Mutations are more likely to be disruptive if they appear in functional sites, resulting in a measurable difference in evolution rates between functional and non-functional genomic segments. Results We have devised a flexible suite of methods for the identification and visualization of conserved transcription-factor-binding sites. The system reports those putative transcription-factor-binding sites that are both situated in conserved regions and located as pairs of sites in equivalent positions in alignments between two orthologous sequences. An underlying collection of metazoan transcription-factor-binding profiles was assembled to facilitate the study. This approach results in a significant improvement in the detection of transcription-factor-binding sites because of an increased signal-to-noise ratio, as demonstrated with two sets of promoter sequences. The method is implemented as a graphical web application, ConSite, which is at the disposal of the scientific community at http://www.phylofoot.org/. Conclusions Phylogenetic footprinting dramatically improves the predictive selectivity of bioinformatic approaches to the analysis of promoter sequences. ConSite delivers unparalleled performance using a novel database of high-quality binding models for metazoan transcription factors. With a dynamic interface, this bioinformatics tool provides broad access to promoter analysis with phylogenetic footprinting.

  9. Test Capability of Comparative NAA Method in Analysis of Long Lived Element in SRM 1648

    International Nuclear Information System (INIS)

    Sri-Wardani

    2005-01-01

    The comparative NAA method had been examine on the analysis of long-lived elements content in air particulate sample of NIST.SRM 1648 for evaluation of a capability of comparative NAA method that used at P2TRR. From the result of analysis it could be determined analysis elements contained in the sample, namely: Sc, Co, Zn, Br, Rb, Sb, Hf and Th with optimum results in bias of 10%. The optimum result of long-lived elements obtained on a good accuracy and precision. From the analysis data obtained showed that the comparative NAA method with Gamma Trac and APTEC software capable to analyze several kinds of elements in environmental samples. Therefore, this method could be implement in biological and healthy samples. (author)

  10. Comparative analysis of C A R A fuel element in argentinean PHWR Argentinas

    International Nuclear Information System (INIS)

    Brasnarof D; Marino, A. C; Florido, P. C; Daverio, H

    2006-01-01

    This paper presents an analysis of the thermal mechanical behaviour, fuel consumption and economical estimations of the CARA fuel element in the Atucha and Embalse nuclear power plants, compared with the present fuel performance.The present results show that the expect profit by the use of the CARA fuel element in our reactor guaranties the recovery of fund for its development. Likewise it reduces the number of spent fuel to be storage and treated [es

  11. The Elements of Competitive Environment of an Enterprise: A Case of Oligopolic Markets Comparative Analysis

    Directory of Open Access Journals (Sweden)

    Algirdas Krivka

    2011-03-01

    Full Text Available The article raises the problem of the complex analysis of competitive environment of an enterprise, which is considered to be the main source of factors, influencing enterprise‘s strategic behaviour and performance. The elements of competitive environment are derived from “traditional” market structure characteristics, developed by the scholars of classical economics and modern microeconomics, with additional factors coming from industrial organization, theoretical oligopoly models, M. Porter’s five competitive forces and diamond. The developed set of the elements of competitive environment is applied for the comparative analysis of three Lithuanian oligopolic markets. The results obtained confirm the potential for practical application of the developed classification for similar analysis.Article in Lithuanian

  12. Comparative analysis of elemental components in airborne particulate matter by k0-NAA methods

    International Nuclear Information System (INIS)

    Chung, Yong-Sam; Moon, Jong-Hwa; Cho, Hyun-Je; Kim, Young-Jin

    2005-01-01

    A comparison of the analytical data obtained by three k 0 -NAA software programs was carried out using both the airborne particulate matter collected from an urban site and the certified reference materials of the air filter and urban dust to evaluate the performance of the analysis. The individual k 0 -NAA standardization methods of three countries, Korea, China and Vietnam which had been modified from the well established k 0 -program were used for the comparative analysis. The measured concentrations of 30 elements from the two kinds of air samples based on this software were in agreement with each other within about 20% analytical error except for a few elements. By contrast, the results of China and Vietnam were moderately higher than that of Korea due to a systematic error associated with the detection efficiency, gamma peak analysis and geometric effect

  13. Comparative measurement of inorganic elements in Korean space foods using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Kim, Sun Ha; Baek, Sung Ryel; Sun, Gwang Min; Moon, Jong Hwa; Choi, Jong Il; Lee, Joo Eun

    2012-01-01

    In April 2008, Korea's first astronaut became a crew member of the international space station and she brought special space versions of traditional Korean dishes such as kimchi, boiled rice, hot red pepper paste, soybean paste soup, ginseng tea, green tea, and ramyun. To date, seventy kinds of Korean space foods (KSFs) have been developed by KAERI. The information and role of trace mineral elements from an intake of created and processed foodstuff are important as a indicator of human health and nutrition, as well as a quality control of food and diet. In particular, special food created for consumption by astronauts in outer space may differ with common food on the earth to compensate a decrease in taste and nutrition by hygienic sterilization processing as well as strong cosmic rays, a state of non gravitation, low pressure, and an enclosed space environment. An accurate quantitative analysis of trace elements in various kinds of biological samples is serious work for analytical data quality. An neutron activation analysis is a sensitive, non destructive, multi elemental analytical method without loss and contamination of a sample by chemical pre treatment. The aim of this study is to identify and to compare the distribution of concentrations for essential and functional inorganic elements in six kinds of Korean space foods developed by KAERI in 2011 using INAA

  14. Comparative measurement of inorganic elements in Korean space foods using instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Yong Sam; Kim, Sun Ha; Baek, Sung Ryel; Sun, Gwang Min; Moon, Jong Hwa; Choi, Jong Il; Lee, Joo Eun [KAERI, Daejeon (Korea, Republic of)

    2012-10-15

    In April 2008, Korea's first astronaut became a crew member of the international space station and she brought special space versions of traditional Korean dishes such as kimchi, boiled rice, hot red pepper paste, soybean paste soup, ginseng tea, green tea, and ramyun. To date, seventy kinds of Korean space foods (KSFs) have been developed by KAERI. The information and role of trace mineral elements from an intake of created and processed foodstuff are important as a indicator of human health and nutrition, as well as a quality control of food and diet. In particular, special food created for consumption by astronauts in outer space may differ with common food on the earth to compensate a decrease in taste and nutrition by hygienic sterilization processing as well as strong cosmic rays, a state of non gravitation, low pressure, and an enclosed space environment. An accurate quantitative analysis of trace elements in various kinds of biological samples is serious work for analytical data quality. An neutron activation analysis is a sensitive, non destructive, multi elemental analytical method without loss and contamination of a sample by chemical pre treatment. The aim of this study is to identify and to compare the distribution of concentrations for essential and functional inorganic elements in six kinds of Korean space foods developed by KAERI in 2011 using INAA.

  15. A comparative finite elemental analysis of glass abutment supported and unsupported cantilever fixed partial denture.

    Science.gov (United States)

    Ramakrishaniah, Ravikumar; Al Kheraif, Abdulaziz A; Elsharawy, Mohamed A; Alsaleh, Ayman K; Ismail Mohamed, Karem M; Rehman, Ihtesham Ur

    2015-05-01

    The purpose of this study was to investigate and compare the load distribution and displacement of cantilever prostheses with and without glass abutment by three dimensional finite element analysis. Micro-computed tomography was used to study the relationship between the glass abutment and the ridge. The external surface of the maxilla was scanned, and a simplified finite element model was constructed. The ZX-27 glass abutment and the maxillary first and second premolars were created and modified. The solid model of the three-unit cantilever fixed partial denture was scanned, and the fitting surface was modified with reference to the created abutments using the 3D CAD system. The finite element analysis was completed in ANSYS. The fit and total gap volume between the glass abutment and dental model were determined by Skyscan 1173 high-energy spiral micro-CT scan. The results of the finite element analysis in this study showed that the cantilever prosthesis supported by the glass abutment demonstrated significantly less stress on the terminal abutment and overall deformation of the prosthesis under vertical and oblique load. Micro-computed tomography determined a gap volume of 6.74162 mm(3). By contacting the mucosa, glass abutments transfer some amount of masticatory load to the residual alveolar ridge, thereby preventing damage to the periodontal microstructures of the terminal abutment. The passive contact of the glass abutment with the mucosa not only preserves the health of the mucosa covering the ridge but also permits easy cleaning. It is possible to increase the success rate of cantilever FPDs by supporting the cantilevered pontic with glass abutments. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  16. Elemental analysis using instrumental neutron activation analysis and inductively coupled plasma atomic emission spectrometry: a comparative study

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Choi, Kwang Soon; Moon, Jong Hwa; Kim, Sun Ha; Lim, Jong Myoung; Kim, Young Jin; Quraishi, Shamshad Begum

    2003-05-01

    Elemental analyses for certified reference materials were carried out using instrumental neutron activation analysis and inductively coupled plasma-atomic emission spectrometry. Five Certified Reference Materials (CRM) were selected for the study on comparative analysis of environmental samples. The CRM are Soil (NIST SRM 2709), Coal fly ash (NIST SRM 1633a), urban dust (NIST SRM 1649a) and air particulate on filter media (NIST SRM 2783 and human hair (GBW 09101)

  17. Comparative analysis of elements and models of implementation in local-level spatial plans in Serbia

    Directory of Open Access Journals (Sweden)

    Stefanović Nebojša

    2017-01-01

    Full Text Available Implementation of local-level spatial plans is of paramount importance to the development of the local community. This paper aims to demonstrate the importance of and offer further directions for research into the implementation of spatial plans by presenting the results of a study on models of implementation. The paper describes the basic theoretical postulates of a model for implementing spatial plans. A comparative analysis of the application of elements and models of implementation of plans in practice was conducted based on the spatial plans for the local municipalities of Arilje, Lazarevac and Sremska Mitrovica. The analysis includes four models of implementation: the strategy and policy of spatial development; spatial protection; the implementation of planning solutions of a technical nature; and the implementation of rules of use, arrangement and construction of spaces. The main results of the analysis are presented and used to give recommendations for improving the elements and models of implementation. Final deliberations show that models of implementation are generally used in practice and combined in spatial plans. Based on the analysis of how models of implementation are applied in practice, a general conclusion concerning the complex character of the local level of planning is presented and elaborated. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. TR 36035: Spatial, Environmental, Energy and Social Aspects of Developing Settlements and Climate Change - Mutual Impacts and Grant no. III 47014: The Role and Implementation of the National Spatial Plan and Regional Development Documents in Renewal of Strategic Research, Thinking and Governance in Serbia

  18. Comparative Study on Interface Elements, Thin-Layer Elements, and Contact Analysis Methods in the Analysis of High Concrete-Faced Rockfill Dams

    Directory of Open Access Journals (Sweden)

    Xiao-xiang Qian

    2013-01-01

    Full Text Available This paper presents a study on the numerical performance of three contact simulation methods, namely, the interface element, thin-layer element, and contact analysis methods, through the analysis of the contact behavior between the concrete face slab and the dam body of a high concrete-faced rockfill dam named Tianshengqiao-I in China. To investigate the accuracy and limitations of each method, the simulation results are compared in terms of the dam deformation, contact stress along the interface, stresses in the concrete face slab, and separation of the concrete face slab from the cushion layer. In particular, the predicted dam deformation and slab separation are compared with the in-situ observation data to classify these methods according to their agreement with the in-situ observations. It is revealed that the interface element and thin-layer element methods have their limitations in predicting contact stress, slab separation, and stresses in the concrete face slab if a large slip occurs. The contact analysis method seems to be the best choice whether the separation is finite or not.

  19. Finite element analysis to compare complete denture and implant-retained overdentures with different attachment systems.

    Science.gov (United States)

    Barão, Valentim Adelino Ricardo; Assunção, Wirley Gonçalves; Tabata, Lucas Fernando; Delben, Juliana Aparecida; Gomes, Erica Alves; de Sousa, Edson Antonio Capello; Rocha, Eduardo Passos

    2009-07-01

    This finite element analysis compared stress distribution on complete dentures and implant-retained overdentures with different attachment systems. Four models of edentulous mandible were constructed: group A (control), complete denture; group B, overdenture retained by 2 splinted implants with bar-clip system; group C, overdenture retained by 2 unsplinted implants with o'ring system; and group D, overdenture retained by 2 splinted implants with bar-clip and 2 distally placed o'ring system. Evaluation was performed on Ansys software, with 100-N vertical load applied on central incisive teeth. The lowest maximum general stress value (in megapascal) was observed in group A (64.305) followed by groups C (119.006), D (258.650), and B (349.873). The same trend occurred in supporting tissues with the highest stress value for cortical bone. Unsplinted implants associated with the o'ring attachment system showed the lowest maximum stress values among all overdenture groups. Furthermore, o'ring system also improved stress distribution when associated with bar-clip system.

  20. Comparative Analysis of Bulge Deformation between 2D and 3D Finite Element Models

    Directory of Open Access Journals (Sweden)

    Qin Qin

    2014-02-01

    Full Text Available Bulge deformation of the slab is one of the main factors that affect slab quality in continuous casting. This paper describes an investigation into bulge deformation using ABAQUS to model the solidification process. A three-dimensional finite element analysis model of the slab solidification process has been first established because the bulge deformation is closely related to slab temperature distributions. Based on slab temperature distributions, a three-dimensional thermomechanical coupling model including the slab, the rollers, and the dynamic contact between them has also been constructed and applied to a case study. The thermomechanical coupling model produces outputs such as the rules of bulge deformation. Moreover, the three-dimensional model has been compared with a two-dimensional model to discuss the differences between the two models in calculating the bulge deformation. The results show that the platform zone exists in the wide side of the slab and the bulge deformation is affected strongly by the ratio of width-to-thickness. The indications are also that the difference of the bulge deformation for the two modeling ways is little when the ratio of width-to-thickness is larger than six.

  1. Comparative analysis of transposable elements highlights mobilome diversity and evolution in vertebrates.

    Science.gov (United States)

    Chalopin, Domitille; Naville, Magali; Plard, Floriane; Galiana, Delphine; Volff, Jean-Nicolas

    2015-01-09

    Transposable elements (TEs) are major components of vertebrate genomes, with major roles in genome architecture and evolution. In order to characterize both common patterns and lineage-specific differences in TE content and TE evolution, we have compared the mobilomes of 23 vertebrate genomes, including 10 actinopterygian fish, 11 sarcopterygians, and 2 nonbony vertebrates. We found important variations in TE content (from 6% in the pufferfish tetraodon to 55% in zebrafish), with a more important relative contribution of TEs to genome size in fish than in mammals. Some TE superfamilies were found to be widespread in vertebrates, but most elements showed a more patchy distribution, indicative of multiple events of loss or gain. Interestingly, loss of major TE families was observed during the evolution of the sarcopterygian lineage, with a particularly strong reduction in TE diversity in birds and mammals. Phylogenetic trends in TE composition and activity were detected: Teleost fish genomes are dominated by DNA transposons and contain few ancient TE copies, while mammalian genomes have been predominantly shaped by nonlong terminal repeat retrotransposons, along with the persistence of older sequences. Differences were also found within lineages: The medaka fish genome underwent more recent TE amplification than the related platyfish, as observed for LINE retrotransposons in the mouse compared with the human genome. This study allows the identification of putative cases of horizontal transfer of TEs, and to tentatively infer the composition of the ancestral vertebrate mobilome. Taken together, the results obtained highlight the importance of TEs in the structure and evolution of vertebrate genomes, and demonstrate their major impact on genome diversity both between and within lineages. © The Author(s) 2015. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution.

  2. The Comparative Analysis of Packaging Design Element to Purchasing Decision Between Coca Cola and Big Cola in Manado

    OpenAIRE

    Gessal, Putri

    2013-01-01

    Packaging can play a very interesting role in the success or failure of a product. Its success depends a lot on how it is designed by its creators. Packaging function to protect the contents of a product lies within the package design. It has the power to influence your choices, and with its carefully thought-out aesthetics can affect your emotions. This aim of the study comparative analysis of packaging design element to purchase decision between Coca Cola and Big Cola with packaging element...

  3. Comparative analysis of nodal and edge finite element method for numerical analysis of 3-D magnetostatic systems

    International Nuclear Information System (INIS)

    Mintchev, Pavel; Dimitrov, Marin; Balinov, Stoimen

    2002-01-01

    The possibilities for applying the Finite Element Method (FEM) with gauged magnetic vector potential and the Edge Element Method (EEM) for three-dimensional numerical analysis of magnetostatic systems are analyzed. It is established that the EEM ensures sufficient accuracy for engineering calculations but in some cases its use results in bad convergence. The use of the FEM with gauged magnetic vector potential instead of the EEM is recommended for preliminary calculations of devices with complex geometry and large air gaps between the ferromagnetic parts. (Author)

  4. Comparative Investigation on Modal analysis of LM25 Aluminium alloy with other Aluminim alloys using Finite element analysis software

    Science.gov (United States)

    Arunkumar, S.; Baskaralal, V. P. M.; Muthuraman, V.

    2017-03-01

    The rudimentary steps of the modal analysis and simulation are carried out. The modal analysis is carried out on the different Aluminum Alloys cantilever beam. The cantilever beam is designed in the graphical environment of the ANSYS. The cantilever beam was fine-tuned on one end with all degree of liberation on this end were taken, beam cannot move and rotate. Mode shapes and natural frequencies are premeditated in platforms ANSYS with arithmetical formulation of the direct solver including the block Lanczos method. Aluminum alloys are widely utilized in much application due to their estimable weight to vigor property. Many examination works have been distributed out to make developments the mechanical properties of aluminum alloys. The composition of alloying elements plays a consequential role in deciding the properties of an alloy. In this study a numerical analysis implement i.e., finite element analysis (FEA) is utilized. The work obtainable in this paper is aimed at the study of effect of modal analysis of different aluminum alloys. The modeling and analysis is carried out utilizing ANSYS FEA software. A modal analysis is carried out to understand the modes of frequency demeanor of the material considered. The modal analysis play a vital role in the design of components subjected to high vibration.

  5. Ultratrace element contents in rat tissues: Comparative analysis of serum and hair as indicative matrices of the total body burden

    Directory of Open Access Journals (Sweden)

    Skalny Anatoly V.

    2016-01-01

    Full Text Available The aim of this study was to investigate the distribution of ultratrace elements in rat tissues and to perform a comparative analysis of hair and serum as potential bioindicators of the total ultratrace element content. Thirty-six male Wistar rats were fed a standard chow containing 0.006±0.000, 0.001±0.000, 0.017±0.002, 0.382±0.031, 0.168±0.014, 3.211±0.134, 0.095±0.006, 0.000±0.000, 6.675±0.336, 15.327±0.564, 0.002±0.000, and 1.185±0.202 μg/g of silver (Ag, gold (Au, cesium (Cs, gallium (Ga, germanium (Ge, lanthanum (La, niobium (Nb, platinum (Pt, rubidium (Rb, titanium (Ti, thallium (Tland zirconium (Zr, respectively, from weaning to 3 months old. The ultratrace element content in the liver, kidney, muscle, heart, serum and hair was assessed using inductively coupled plasma mass spectrometry. The obtained data indicate that the highest concentrations of most of the studied elements (Ti, Zr, Ge, Nb, tungsten (W, La, uranium (U, Ag, Au, Pt are in hair, whereas the lowest were observed in the serum. Statistical analysis revealed a significant association between concentrations in the hair and other tissues for Cs, Ti, Nb, Tl, La, U and Au. At the same time, serum Cs, Rb, Ti, Ge, Nb, W, Ga, Tl and La concentrations significantly correlated with the tissue content of the respective ultratrace elements. It can be concluded that hair may be used as a potential bioindicator for certain ultratrace element content in the mammalian organism.

  6. Finite element analysis of vibration energy harvesting using lead-free piezoelectric materials: A comparative study

    Directory of Open Access Journals (Sweden)

    Anuruddh Kumar

    2014-06-01

    Full Text Available In this article, the performance of various piezoelectric materials is simulated for the unimorph cantilever-type piezoelectric energy harvester. The finite element method (FEM is used to model the piezolaminated unimorph cantilever structure. The first-order shear deformation theory (FSDT and linear piezoelectric theory are implemented in finite element simulations. The genetic algorithm (GA optimization approach is carried out to optimize the structural parameters of mechanical energy-based energy harvester for maximum power density and power output. The numerical simulation demonstrates the performance of lead-free piezoelectric materials in unimorph cantilever-based energy harvester. The lead-free piezoelectric material K0.5Na0.5NbO3-LiSbO3-CaTiO3 (2 wt.% has demonstrated maximum mean power and maximum mean power density for piezoelectric energy harvester in the ambient frequency range of 90–110 Hz. Overall, the lead-free piezoelectric materials of K0.5Na0.5NbO3-LiSbO3 (KNN-LS family have shown better performance than the conventional lead-based piezoelectric material lead zirconate titanate (PZT in the context of piezoelectric energy harvesting devices.

  7. A Comparative Analysis of the Universal Elements of Music and the Fetal Environment

    Science.gov (United States)

    Teie, David

    2016-01-01

    Although the idea that pulse in music may be related to human pulse is ancient and has recently been promoted by researchers (Parncutt, 2006; Snowdon and Teie, 2010), there has been no ordered delineation of the characteristics of music that are based on the sounds of the womb. I describe features of music that are based on sounds that are present in the womb: tempo of pulse (pulse is understood as the regular, underlying beat that defines the meter), amplitude contour of pulse, meter, musical notes, melodic frequency range, continuity, syllabic contour, melodic rhythm, melodic accents, phrase length, and phrase contour. There are a number of features of prenatal development that allow for the formation of long-term memories of the sounds of the womb in the areas of the brain that are responsible for emotions. Taken together, these features and the similarities between the sounds of the womb and the elemental building blocks of music allow for a postulation that the fetal acoustic environment may provide the bases for the fundamental musical elements that are found in the music of all cultures. This hypothesis is supported by a one-to-one matching of the universal features of music with the sounds of the womb: (1) all of the regularly heard sounds that are present in the fetal environment are represented in the music of every culture, and (2) all of the features of music that are present in the music of all cultures can be traced to the fetal environment. PMID:27555828

  8. Stress distribution patterns of implant supported overdentures-analog versus finite element analysis: A comparative in-vitro study

    Directory of Open Access Journals (Sweden)

    Soumyadev Satpathy

    2015-01-01

    Full Text Available Aims and Objectives: The aim of this study was to asses & compare the load transfer characteristics of Ball/O-ring and Bar/Clip attachment systems in implant supported overdentures using analog and finite element analysis models. Methodology: For the analog part of the study, castable bar was used for the bar and clip attachment and a metallic housing with a rubber O-ring component was used for the ball/O-ring attachment. The stress on the implant surface was measured using the strain-gauge technique. For the finite element analysis, the model were fabricated and load applications were done in a similar manner as in analog study. Results: The difference between both the attachment systems was found to be statistically significant (P<0.001. Conclusion: Ball/O-ring attachment system transmitted lesser amount of stresses to the implants on the non-loading side, as compared to the Bar-Clip attachment system. When overall stress distribution is compared, the Bar-Clip attachment seems to perform better than the Ball/O-ring attachment, because the force was distributed better.

  9. Comparative element analysis on femur of antler hemo-treated ovariectomized wistar rats by SRXRF

    International Nuclear Information System (INIS)

    Yang Jianhong; Fei Yurong; Wang Ruilin; Cao Yi; Huang Yuying; He Wei

    2007-01-01

    To investigate the relationship between bone element contents and bone m/neral density (BMD), left femur of sham-operated rats (SHAM, n=5), ovariectomized rats (OVX, n=5) and antler hemo-treated ovariectomized rats (OVX + antler hemo, n=5) were analyzed by synchrotron radiation X-ray fluorescence (SRXRF) microprobe. The results showed that there were very good positive correlations among contents of Ca, P, Zn and Sr. In comparison to the SHAM group, decreased relative intensities of Ca, P, Zn and Sr (especially Ca and P, p<0.05) were observed in femur of the OVX group, which showed significant decrease (p<0.05) of the BMD. The results indicate that loss of Ca and P in bone will cause osteoporosis. On the other hand, increased relative intensities of Ca, P and Zn in femur, and the BMD (p<0.05), of the anlter hemo-treated OVX group were found, in comparison to the OVX group. This suggests that anlter hemo may help cure osteoporosis through maintaining bone contents of Zn, Ca and P, and increasing the BMD. (authors)

  10. Comparative analysis of regulatory elements between Escherichia coli and Klebsiella pneumoniae by genome-wide transcription start site profiling.

    Directory of Open Access Journals (Sweden)

    Donghyuk Kim

    Full Text Available Genome-wide transcription start site (TSS profiles of the enterobacteria Escherichia coli and Klebsiella pneumoniae were experimentally determined through modified 5' RACE followed by deep sequencing of intact primary mRNA. This identified 3,746 and 3,143 TSSs for E. coli and K. pneumoniae, respectively. Experimentally determined TSSs were then used to define promoter regions and 5' UTRs upstream of coding genes. Comparative analysis of these regulatory elements revealed the use of multiple TSSs, identical sequence motifs of promoter and Shine-Dalgarno sequence, reflecting conserved gene expression apparatuses between the two species. In both species, over 70% of primary transcripts were expressed from operons having orthologous genes during exponential growth. However, expressed orthologous genes in E. coli and K. pneumoniae showed a strikingly different organization of upstream regulatory regions with only 20% identical promoters with TSSs in both species. Over 40% of promoters had TSSs identified in only one species, despite conserved promoter sequences existing in the other species. 662 conserved promoters having TSSs in both species resulted in the same number of comparable 5' UTR pairs, and that regulatory element was found to be the most variant region in sequence among promoter, 5' UTR, and ORF. In K. pneumoniae, 48 sRNAs were predicted and 36 of them were expressed during exponential growth. Among them, 34 orthologous sRNAs between two species were analyzed in depth, and the analysis showed that many sRNAs of K. pneumoniae, including pleiotropic sRNAs such as rprA, arcZ, and sgrS, may work in the same way as in E. coli. These results reveal a new dimension of comparative genomics such that a comparison of two genomes needs to be comprehensive over all levels of genome organization.

  11. Genome-wide comparative analysis of 20 miniature inverted-repeat transposable element families in Brassica rapa and B. oleracea.

    Directory of Open Access Journals (Sweden)

    Perumal Sampath

    Full Text Available Miniature inverted-repeat transposable elements (MITEs are ubiquitous, non-autonomous class II transposable elements. Here, we conducted genome-wide comparative analysis of 20 MITE families in B. rapa, B. oleracea, and Arabidopsis thaliana. A total of 5894 and 6026 MITE members belonging to the 20 families were found in the whole genome pseudo-chromosome sequences of B. rapa and B. oleracea, respectively. Meanwhile, only four of the 20 families, comprising 573 members, were identified in the Arabidopsis genome, indicating that most of the families were activated in the Brassica genus after divergence from Arabidopsis. Copy numbers varied from 4 to 1459 for each MITE family, and there was up to 6-fold variation between B. rapa and B. oleracea. In particular, analysis of intact members showed that whereas eleven families were present in similar copy numbers in B. rapa and B. oleracea, nine families showed copy number variation ranging from 2- to 16-fold. Four of those families (BraSto-3, BraTo-3, 4, 5 were more abundant in B. rapa, and the other five (BraSto-1, BraSto-4, BraTo-1, 7 and BraHAT-1 were more abundant in B. oleracea. Overall, 54% and 51% of the MITEs resided in or within 2 kb of a gene in the B. rapa and B. oleracea genomes, respectively. Notably, 92 MITEs were found within the CDS of annotated genes, suggesting that MITEs might play roles in diversification of genes in the recently triplicated Brassica genome. MITE insertion polymorphism (MIP analysis of 289 MITE members showed that 52% and 23% were polymorphic at the inter- and intra-species levels, respectively, indicating that there has been recent MITE activity in the Brassica genome. These recently activated MITE families with abundant MIP will provide useful resources for molecular breeding and identification of novel functional genes arising from MITE insertion.

  12. Comparative trace elemental analysis of cancerous and non-cancerous tissues of rectal cancer patients using PIXE

    Science.gov (United States)

    Naga Raju, G. J.; Sarita, P.; Murthy, K. S. R.

    2017-08-01

    Particle Induced X-ray Emission (PIXE), an accelerator based analytical technique has been employed in this work for the analysis of trace elements in the cancerous and non-cancerous tissues of rectal cancer patients. A beam of 3 MeV protons generated from 3 MV Pelletron accelerator at the Ion Beam Laboratory of Institute of Physics, Bhubaneswar, India was used as projectile to excite the atoms present in the tissues samples. PIXE technique, with its capability to detect simultaneously several elements present at very low concentrations, offers an excellent tool for trace element analysis. The characteristic X-rays emitted by the samples were recorded by a high resolution Si (Li) detector. On the basis of the PIXE spectrum obtained for each sample, the elements Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, and Br were identified and their relative concentrations were estimated in the cancerous and non-cancerous tissues of rectum. The levels of Mn, Fe, Co, Cu, Zn, and As were higher (p < 0.005) while the levels of Ca, Cr and Ni were lower (p < 0.005) in the cancer tissues relative to the normal tissues. The alterations in the levels of the trace elements observed in the present work are discussed in this paper with respect to their potential role in the initiation, promotion and inhibition of cancer of the rectum.

  13. Comparative analysis of unilateral removable partial denture and classical removable partial denture by using finite element method

    Directory of Open Access Journals (Sweden)

    Radović Katarina

    2010-01-01

    Full Text Available Introduction. Various mobile devices are used in the therapy of unilateral free-end saddle. Unilateral dentures with precise connectivity elements are not used frequently. In this paper the problem of applying and functionality of unilateral freeend saddle denture without major connector was taken into consideration. Objective. The aim was to analyze and compare a unilateral RPD (removable partial denture and a classical RPD by calculating and analyzing stresses under different loads. Methods. 3D models of unilateral removable partial denture and classical removable partial denture with casted clasps were made by using computer program CATIA V5 (abutment teeth, canine and first premolar, with crowns and abutment tissues were also made. The models were built in full-scale. Stress analyses for both models were performed by applying a force of 300 N on the second premolar, a force of 500 N on the first molar and a force of 700 N on the second molar. Results. The Fault Model Extractor (FME analysis and calculation showed the complete behavior of unilateral removable partial denture and abutments (canine and first premolar, as well as the behavior of RPD under identical loading conditions. Applied forces with extreme values caused high stress levels on both models and their abutments within physiological limits. Conclusion. Having analyzed stresses under same conditions, we concluded that the unilateral RPD and classical RPD have similar physiological values.

  14. A comparative study of minor and trace elements in human, animal and commercial milk samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Garg, A.N.; Weginwar, R.G.; Chutke, N.L.

    1993-01-01

    Human, animal (cow, buffalo and goat) and commercial milk powders (for infants and adults) have been analyzed for 5 minor (Na, K, Mg, Cl and P) and 13 trace elements (Cr, Mn, Fe, Co, Cu, Zn, Cd, Hg, As, Se, Sb, Cs and Br) by instrumental and radiochemical neutron activation. Milk standards NIST SRM 1549 and IAEA A-11 along with diet standards RM 8431a and IAEA H-9 were also analyzed for quality assurance. The method involves thermal neutron irradiation for 10 m, 1 h, 6 h and 1 week in a reactor followed by high resolution γ-spectrometry. Concentrations of Fe, Co, Zn, Sb and Se were also determined by radiochemical solvent extraction. Mean concentrations of Na, K, Mg, P, Cl, Fe, Mn and Cu in human milk (colostrum) are comparable with that of a WHO/IAEA study. It has, however, lower contents of toxic trace elements (Cr, Cd, Hg, Br, Se, Sb and As) compared to breast tissue from the same area. Cow milk is richer in Na, K, Cl, Mn and Se but it has comparable amounts of Mg, Zn, Br, Fe and Sb with respect to breast milk. Significant differences have been observed for elemental concentrations of Na, K, P and Fe in commercial formula milk powders for infants and adults. Infant's milk powders contain all the nutrient elements in balanced amounts required for the higher growth rate of a child. (author) 41 refs.; 2 figs.; 3 tabs

  15. Comparative study of finite element method, isogeometric analysis, and finite volume method in elastic wave propagation of stress discontinuities

    Czech Academy of Sciences Publication Activity Database

    Berezovski, A.; Kolman, Radek; Blažek, Jiří; Kopačka, Ján; Gabriel, Dušan; Plešek, Jiří

    2014-01-01

    Roč. 19, č. 12 (2014) ISSN 1435-4934. [European Conference on Non-Destructive Testing (ECNDT 2014) /11./. Praha, 06.10.2014-10.10.2014] R&D Projects: GA ČR(CZ) GAP101/11/0288; GA ČR(CZ) GAP101/12/2315 Institutional support: RVO:61388998 Keywords : elastic wave propagation * finite element method * isogeometric analysis * finite volume method * stress discontinuities * spurious oscillations Subject RIV: JR - Other Machinery http://www.ndt.net/events/ECNDT2014/app/content/Paper/25_Berezovski_Rev1.pdf

  16. Comparative analysis of torsional and bending behavior through finite-element models of 5 Ni-Ti endodontic instruments.

    Science.gov (United States)

    Arbab-Chirani, Reza; Chevalier, Valérie; Arbab-Chirani, Shabnam; Calloch, Sylvain

    2011-01-01

    The objectives of this study were to compare numerically the bending and torsional mechanical behavior of 5 endodontic rotary Ni-Ti instruments with equivalent size and various designs for tapers, pitch, and cutting blades.First, the geometries of Hero (20/0.06), HeroShaper (20/0.06), ProFile (20/0.06), Mtwo (20/0.06), and ProTaper F1 were generated by finite element code. Then, the 2 most representative clinical loadings, i.e., bending and torsion, were studied with an ad hoc model for the superelasticity of Ni-Ti. Bending was generated by tip deflection and torsion by a constant twist-angle of the tip. Mechanical behavior of these 5 endodontic rotary Ni-Ti instruments could be evaluated and compared. Protaper F1 presented the greatest level of bending stress and torque. Hero and HeroShaper were more rigid than ProFile and Mtwo. This numerical comparison evaluated the effects of the geometrical parameters on the instrumental mechanical behavior. The 5 endodontic instruments, investigated in the present study, do not have the same bending and torsional mechanical behavior. Each clinician must be aware of these behavior differences so as to use the adequate file according to the clinical situation and to the manufacturer's recommendations. Copyright © 2011 Mosby, Inc. All rights reserved.

  17. A Comparative Experimental Study on Identification of Defect Severity in Rolling Element Bearings using Acoustic Emission and Vibration Analysis

    Directory of Open Access Journals (Sweden)

    V.V. Rao

    2015-06-01

    Full Text Available This paper describes the comparison between Vibration Analysis (VA and Acoustic Emission (AE method to predict the defect severity in rolling element bearings with respect to the gradual increase of defect size. In bearing fault diagnosis vibration based methods are very popular, but the signals acquired by its transducers from the bearings are distorted by other faults and mechanical noise from the equipment. Vibration based methods are effective when the defect in the bearings has already become severe. AE is a non destructive testing (NDT technique used in structural health monitoring and its application for bearing defect diagnosis is gaining momentum as an alternate diagnostic tool because of its inherent high signal-to-noise-ratio (SNR. A bearing test rig was designed and set up to study the various defects in rolling element bearings in real environment. In earlier cases, though the researchers studied on different types of seeded defects with random sizes, they could not ascertain the correlation between their defect sizes and the vibration amplitude. The experimental investigation reported in this paper is centered on seeded defect of same type with gradual increase of its size on outer race of radially loaded cylindrical roller bearings and running the defective bearing at different speeds and loads. Data acquired through AE & vibration probes simultaneously for better diagnosis. Comparisons between AE and VA over a range of speed and load conditions at gradual increase of defect size are presented and from them it is concluded that AE method is superior to identify the severity of defect.

  18. Comparative analysis of pepper and tomato reveals euchromatin expansion of pepper genome caused by differential accumulation of Ty3/Gypsy-like elements

    Directory of Open Access Journals (Sweden)

    Ahn Jong Hwa

    2011-01-01

    Full Text Available Abstract Background Among the Solanaceae plants, the pepper genome is three times larger than that of tomato. Although the gene repertoire and gene order of both species are well conserved, the cause of the genome-size difference is not known. To determine the causes for the expansion of pepper euchromatic regions, we compared the pepper genome to that of tomato. Results For sequence-level analysis, we generated 35.6 Mb of pepper genomic sequences from euchromatin enriched 1,245 pepper BAC clones. The comparative analysis of orthologous gene-rich regions between both species revealed insertion of transposons exclusively in the pepper sequences, maintaining the gene order and content. The most common type of the transposon found was the LTR retrotransposon. Phylogenetic comparison of the LTR retrotransposons revealed that two groups of Ty3/Gypsy-like elements (Tat and Athila were overly accumulated in the pepper genome. The FISH analysis of the pepper Tat elements showed a random distribution in heterochromatic and euchromatic regions, whereas the tomato Tat elements showed heterochromatin-preferential accumulation. Conclusions Compared to tomato pepper euchromatin doubled its size by differential accumulation of a specific group of Ty3/Gypsy-like elements. Our results could provide an insight on the mechanism of genome evolution in the Solanaceae family.

  19. Elements of real analysis

    CERN Document Server

    Sprecher, David A

    2010-01-01

    This classic text in introductory analysis delineates and explores the intermediate steps between the basics of calculus and the ultimate stage of mathematics: abstraction and generalization.Since many abstractions and generalizations originate with the real line, the author has made it the unifying theme of the text, constructing the real number system from the point of view of a Cauchy sequence (a step which Dr. Sprecher feels is essential to learn what the real number system is).The material covered in Elements of Real Analysis should be accessible to those who have completed a course in

  20. A comparative study of laser induced breakdown spectroscopy analysis for element concentrations in aluminum alloy using artificial neural networks and calibration methods

    International Nuclear Information System (INIS)

    Inakollu, Prasanthi; Philip, Thomas; Rai, Awadhesh K.; Yueh Fangyu; Singh, Jagdish P.

    2009-01-01

    A comparative study of analysis methods (traditional calibration method and artificial neural networks (ANN) prediction method) for laser induced breakdown spectroscopy (LIBS) data of different Al alloy samples was performed. In the calibration method, the intensity of the analyte lines obtained from different samples are plotted against their concentration to form calibration curves for different elements from which the concentrations of unknown elements were deduced by comparing its LIBS signal with the calibration curves. Using ANN, an artificial neural network model is trained with a set of input data of known composition samples. The trained neural network is then used to predict the elemental concentration from the test spectra. The present results reveal that artificial neural networks are capable of predicting values better than traditional method in most cases

  1. Comparative three-dimensional finite element analysis of implant-supported fixed complete arch mandibular prostheses in two materials.

    Science.gov (United States)

    Tribst, João Paulo Mendes; de Morais, Dayana Campanelli; Alonso, Alexandre Abhdala; Piva, Amanda Maria de Oliveira Dal; Borges, Alexandre Luis Souto

    2017-01-01

    The increase of requests for implant-supported prosthesis (ISP) with zirconia as infrastructure has attracted a lot of attention due to its esthetics, biocompatibility, and survival rate similar to metallic infrastructure. The aim of this study was to evaluate the influence of two different framework materials on stress distribution over a bone tissue-simulating material. Two ISP were modeled and divided into two infrastructure materials: titanium (Ti) and zirconia. Then, these bars were attached to a modeled jaw with polyurethane properties to simulate bone tissue. An axial load of 200 N was applied on a standardized area for both systems. Maximum principal stress (MPS) on solids and microstrain (MS) generated through the jaw were analyzed by finite element analysis. According to MS, both models showed strains on peri-implant region of the penultimate (same side of the load application) and central implants. For MPS, more stress concentration was slightly higher in the left posterior region for Ti's bar. In prosthetic fixation screws, the MPS prevailed strongly in Ti protocol, while for zirconia's bar, the cervical of the penultimate implant was the one that highlighted larger areas of possible damages. The stress generated in all constituents of the system was not significantly influenced by the framework's material. This allows suggesting that in cases without components, the use of a framework in zirconia has biomechanical behavior similar to that of a Ti bar.

  2. Comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: An in vitro study

    OpenAIRE

    Krishna Chaitanya Kanneganti; Dileep Nag Vinnakota; Srinivas Rao Pottem; Mahesh Pulagam

    2018-01-01

    Purpose: The purpose of this study is to compare the effect of implant-abutment connections, abutment angulations, and screw lengths on screw loosening (SL) of preloaded abutment using three dimensional (3D) finite element analysis. Materials and Methods: 3D models of implants (conical connection with hex/trilobed connections), abutments (straight/angulated), abutment screws (short/long), and crown and bone were designed using software Parametric Technology Corporation Creo and assembled t...

  3. Comparative evaluation of trace elements in blood

    International Nuclear Information System (INIS)

    Goeij, J.J.M. de; Tjioe, P.S.; Pries, C.; Zwiers, J.H.L.

    1976-01-01

    The Interuniversitair Reactor Instituut and the Centraal Laboratorium TNO have carried out a common investigation on neutron-activation-analytical procedures for the determination of trace elements in blood. A comparative evaluation of five methods, destructive as well as non-destructive, is given. The sensitivity and reproducibility of the procedures are discussed. By combining some of the methods it is possible, starting with 1 ml blood, to give quantitative information on 14 important trace elements: antimony, arsenic, bromine, cadmium, cobalt, gold, copper, mercury, molybdenum, nickel, rubidium, selenium, iron and zinc. The methods have also been applied to sodium, chromium and potassium

  4. Machined and plastic copings in three-element prostheses with different types of implantabutment joints: a strain gauge comparative analysis

    Directory of Open Access Journals (Sweden)

    Renato Sussumu Nishioka

    2010-06-01

    Full Text Available OBJECTIVE: Using strain gauge (SG analysis, the aim of this in vitro study was quantify the strain development during the fixation of three-unit screw implant-supported fixed partial dentures, varying the types of implant-abutment joints and the type of prosthetic coping. The hypotheses were that the type of hexagonal connection would generate different microstrains and the type of copings would produce similar microstrains after prosthetic screws had been tightened onto microunit abutments. MATERIALS AND METHODS: Three dental implants with external (EH and internal (IH hexagonal configurations were inserted into two polyurethane blocks. Microunit abutments were screwed onto their respective implant groups, applying a torque of 20 Ncm. Machined Co-Cr copings (M and plastic prosthetic copings (P were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in Co-Cr alloy (n=5, forming four groups: G1 EH/M; G2 EH/P; G3 IH/M and G4 IH/P. Four SGs were bonded onto the surface of the block tangentially to the implants, SG 1 mesially to implant 1, SG 2 and SG 3 mesially and distally to implant 2, respectively, and SG 4 distally to implant 3. The superstructure's occlusal screws were tightened onto microunit abutments with 10 Ncm torque using a manual torque driver. The magnitude of microstrain on each SG was recorded in units of microstrain (µε. The data were analyzed statistically by ANOVA and Tukey's test (p0.05. The hypotheses were partially accepted. CONCLUSIONS: It was concluded that the type of hexagonal connection and coping presented similar mechanical behavior under tightening conditions.

  5. Comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: An in vitro study.

    Science.gov (United States)

    Kanneganti, Krishna Chaitanya; Vinnakota, Dileep Nag; Pottem, Srinivas Rao; Pulagam, Mahesh

    2018-01-01

    The purpose of this study is to compare the effect of implant-abutment connections, abutment angulations, and screw lengths on screw loosening (SL) of preloaded abutment using three dimensional (3D) finite element analysis. 3D models of implants (conical connection with hex/trilobed connections), abutments (straight/angulated), abutment screws (short/long), and crown and bone were designed using software Parametric Technology Corporation Creo and assembled to form 8 simulations. After discretization, the contact stresses developed for 150 N vertical and 100 N oblique load applications were analyzed, using ABAQUS. By assessing damage initiation and shortest fatigue load on screw threads, the SL for 2.5, 5, and 10 lakh cyclic loads were estimated, using fe-safe program. The obtained values were compared for influence of connection design, abutment angulation, and screw length. In straight abutment models, conical connection showed more damage (14.3%-72.3%) when compared to trilobe (10.1%-65.73%) at 2.5, 5, and 10 lakh cycles for both vertical and oblique loads, whereas in angulated abutments, trilobe (16.1%-76.9%) demonstrated more damage compared to conical (13.5%-70%). Irrespective of the connection type and abutment angulation, short screws showed more percentage of damage compared to long screws. The present study suggests selecting appropriate implant-abutment connection based on the abutment angulation, as well as preferring long screws with more number of threads for effective preload retention by the screws.

  6. Comparing the influence of crestal cortical bone and sinus floor cortical bone in posterior maxilla bi-cortical dental implantation: a three-dimensional finite element analysis.

    Science.gov (United States)

    Yan, Xu; Zhang, Xinwen; Chi, Weichao; Ai, Hongjun; Wu, Lin

    2015-05-01

    This study aimed to compare the influence of alveolar ridge cortical bone and sinus floor cortical bone in sinus areabi-cortical dental implantation by means of 3D finite element analysis. Three-dimensional finite element (FE) models in a posterior maxillary region with sinus membrane and the same height of alveolar ridge of 10 mm were generated according to the anatomical data of the sinus area. They were either with fixed thickness of crestal cortical bone and variable thickness of sinus floor cortical bone or vice versa. Ten models were assumed to be under immediate loading or conventional loading. The standard implant model based on the Nobel Biocare implant system was created via computer-aided design software. All materials were assumed to be isotropic and linearly elastic. An inclined force of 129 N was applied. Von Mises stress mainly concentrated on the surface of crestal cortical bone around the implant neck. For all the models, both the axial and buccolingual resonance frequencies of conventional loading were higher than those of immediate loading; however, the difference is less than 5%. The results showed that bi-cortical implant in sinus area increased the stability of the implant, especially for immediately loading implantation. The thickness of both crestal cortical bone and sinus floor cortical bone influenced implant micromotion and stress distribution; however, crestal cortical bone may be more important than sinus floor cortical bone.

  7. Comparative measurement of silicon and major elements (P,S,Cl,K,Ca) in arterial walls using macro and microbeam analysis

    International Nuclear Information System (INIS)

    Moretto, P.

    1987-01-01

    There are few techniques available for the measurement of silicon at trace levels in biological materials. PIXE and prompt nuclear reaction analysis were used to locate and measure silicon and major elements in arterial walls. Macrobeam analysis, carried out by the Van de Graaff accelerator at CENBG, enabled measurement of mean tissue levels. Microbeam analysis, using the nuclear microprobe at Karlsruhe, yielded the distribution of these elements through the thickness of the arterial wall. The microanalyses were performed on arterial walls from healthy rabbits and the macrobeam study was carried out on the same samples and also on human aorta specimens [fr

  8. Comparative Study of Radon Concentration with Two Techniques and Elemental Analysis in Drinking Water Samples of the Jammu District, Jammu and Kashmir, India.

    Science.gov (United States)

    Kumar, Ajay; Kaur, Manpreet; Mehra, Rohit; Sharma, Dinesh Kumar; Mishra, Rosaline

    2017-10-01

    The level of radon concentration has been assessed using the Advanced SMART RnDuo technique in 30 drinking water samples from Jammu district, Jammu and Kashmir, India. The water samples were collected from wells, hand pumps, submersible pumps, and stored waters. The randomly obtained 14 values of radon concentration in water sources using the SMART RnDuo technique have been compared and cross checked by a RAD7 device. A good positive correlation (R = 0.88) has been observed between the two techniques. The overall value of radon concentration in various water sources has ranged from 2.45 to 18.43 Bq L, with a mean value of 8.24 ± 4.04 Bq L, and it agreed well with the recommended limit suggested by the European Commission and UNSCEAR. However, the higher activity of mean radon concentration was found in groundwater drawn from well, hand and submersible pumps as compared to stored water. The total annual effective dose due to radon inhalation and ingestion ranged from 6.69 to 50.31 μSv y with a mean value of 22.48 ± 11.03 μSv y. The total annual effective dose was found to lie within the safe limit (100 μSv y) suggested by WHO. Heavy metal analysis was also carried out in various water sources by using an atomic absorption spectrophotometer (AAS), and the highest value of heavy metals was found mostly in groundwater samples. The obtained results were compared with Indian and International organizations like WHO and the EU Council. Among all the samples, the elemental analysis is not on the exceeding side of the permissible limit.

  9. A CAREM type fuel element dynamic analysis

    International Nuclear Information System (INIS)

    Magoia, J.E.

    1990-01-01

    A first analysis on the dynamic behaviour of a fuel element designed for the CAREM nuclear reactor (Central Argentina de Elementos Modulares) was performed. The model used to represent this dynamic behaviour was satisfactorily evaluated. Using primary estimations for some of its numerical parameters, a first approximation to its natural vibrational modes was obtained. Results obtained from fuel elements frequently used in nuclear power plants of the PWR (Pressurized Water Reactors) type, are compared with values resulting from similar analysis. (Author) [es

  10. FINITE ELEMENT ANALYSIS OF ELEMENT ANALYSIS OF A FREE ...

    African Journals Online (AJOL)

    eobe

    the stairs and to compare the finite element ana ... tual three dimensional behavior of the stair slab system. ..... due to its close relation of output with the propo .... flights. It is best not to consider any open well when .... thermodynamics of solids.

  11. Modelling optimization involving different types of elements in finite element analysis

    International Nuclear Information System (INIS)

    Wai, C M; Rivai, Ahmad; Bapokutty, Omar

    2013-01-01

    Finite elements are used to express the mechanical behaviour of a structure in finite element analysis. Therefore, the selection of the elements determines the quality of the analysis. The aim of this paper is to compare and contrast 1D element, 2D element, and 3D element used in finite element analysis. A simple case study was carried out on a standard W460x74 I-beam. The I-beam was modelled and analyzed statically with 1D elements, 2D elements and 3D elements. The results for the three separate finite element models were compared in terms of stresses, deformation and displacement of the I-beam. All three finite element models yield satisfactory results with acceptable errors. The advantages and limitations of these elements are discussed. 1D elements offer simplicity although lacking in their ability to model complicated geometry. 2D elements and 3D elements provide more detail yet sophisticated results which require more time and computer memory in the modelling process. It is also found that the choice of element in finite element analysis is influence by a few factors such as the geometry of the structure, desired analysis results, and the capability of the computer

  12. Evaluation of Bone Atrophy After Treatment of Forearm Fracture Using Nonlinear Finite Element Analysis: A Comparative Study of Locking Plates and Conventional Plates.

    Science.gov (United States)

    Matsuura, Yusuke; Rokkaku, Tomoyuki; Suzuki, Takane; Thoreson, Andrew Ryan; An, Kai-Nan; Kuniyoshi, Kazuki

    2017-08-01

    Forearm diaphysis fractures are usually managed by open reduction internal fixation. Recently, locking plates have been used for treatment. In the long-term period after surgery, some patients present with bone atrophy adjacent to the plate. However, a comparison of locking and conventional plates as a cause of atrophy has not been reported. The aim of this study was to investigate long-term bone atrophy associated with use of locking and conventional plates for forearm fracture treatment. In this study we included 15 patients with forearm fracture managed by either locking or conventional plates and with more than 5 years of follow-up. Computed tomographic imaging of both forearms was performed to assess bone thickness and local bone mineral density and to predict bone strength without plate reinforcement based on finite element analysis. Mean patient age at surgery was 48.0 years. Eight patients underwent reduction with fixed locking plates and were followed up for a mean of 79.5 months; the remaining 7 patients were treated with conventional plates and were followed up for a mean of 105.0 months. Compared with the conventional plate group, the locking plate group had the same fractured limb-contralateral limb ratio of cortex bone thickness, but had significantly lower ratios of mineral density adjacent to the plate and adjusted bone strength. This study demonstrated bone atrophy after locking plate fixation for forearm fractures. Treatment plans for forearm fracture should take into consideration the impact of bone atrophy long after plate fixation. Therapeutic IV. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  13. METHODOLOGICAL ELEMENTS OF SITUATIONAL ANALYSIS

    Directory of Open Access Journals (Sweden)

    Tetyana KOVALCHUK

    2016-07-01

    Full Text Available The article deals with the investigation of theoretical and methodological principles of situational analysis. The necessity of situational analysis is proved in modern conditions. The notion “situational analysis” is determined. We have concluded that situational analysis is a continuous system study which purpose is to identify dangerous situation signs, to evaluate comprehensively such signs influenced by a system of objective and subjective factors, to search for motivated targeted actions used to eliminate adverse effects of the exposure of the system to the situation now and in the future and to develop the managerial actions needed to bring the system back to norm. It is developed a methodological approach to the situational analysis, its goal is substantiated, proved the expediency of diagnostic, evaluative and searching functions in the process of situational analysis. The basic methodological elements of the situational analysis are grounded. The substantiation of the principal methodological elements of system analysis will enable the analyst to develop adaptive methods able to take into account the peculiar features of a unique object which is a situation that has emerged in a complex system, to diagnose such situation and subject it to system and in-depth analysis, to identify risks opportunities, to make timely management decisions as required by a particular period.

  14. Elemental analysis with external-beam PIXE

    Science.gov (United States)

    Lin, E. K.; Wang, C. W.; Teng, P. K.; Huang, Y. M.; Chen, C. Y.

    1992-05-01

    A beamline system and experimental setup has been established for elemental analysis using PIXE with an external beam. Experiments for the study of the elemental composition of ancient Chinese potsherds (the Min and Ching ages) were performed. Continuum X-ray spectra from the samples bombarded by 3 MeV protons have been measured with a Si(Li) detector. From the analysis of PIXE data, the concentration of the main elements (Al, Si, K, and Ca) and of more than ten trace elements in the matrices and glazed surfaces were determined. Results for two different potsherds are presented, and those obtained from the glaze colorants are compared with the results of measurements on a Ching blue-and-white porcelain vase.

  15. Elements of abstract harmonic analysis

    CERN Document Server

    Bachman, George

    2013-01-01

    Elements of Abstract Harmonic Analysis provides an introduction to the fundamental concepts and basic theorems of abstract harmonic analysis. In order to give a reasonably complete and self-contained introduction to the subject, most of the proofs have been presented in great detail thereby making the development understandable to a very wide audience. Exercises have been supplied at the end of each chapter. Some of these are meant to extend the theory slightly while others should serve to test the reader's understanding of the material presented. The first chapter and part of the second give

  16. ED-XRF spectrometric analysis of comparative elemental composition of in vivo and in vitro roots of Andrographis paniculata (Burm.f.) Wall. ex Nees-a multi-medicinal herb

    Energy Technology Data Exchange (ETDEWEB)

    Behera, P.R., E-mail: priyaranjan2004@gmail.co [Plant Cell and Tissue culture Facility, Post-Graduate Department of Botany, Utkal University, Vani Vihar, Bhubaneswar 751004, Orissa (India); Plant Biotechnology Lab, Institute of Minerals and Materials Technology (CSIR), Bhubaneswar 751013, Orissa (India); Nayak, P [Plant Cell and Tissue culture Facility, Post-Graduate Department of Botany, Utkal University, Vani Vihar, Bhubaneswar 751004, Orissa (India); Plant Biotechnology Lab, Institute of Minerals and Materials Technology (CSIR), Bhubaneswar 751013, Orissa (India); Barik, D.P., E-mail: barikdp@yahoo.co [Plant Cell and Tissue culture Facility, Post-Graduate Department of Botany, Utkal University, Vani Vihar, Bhubaneswar 751004, Orissa (India); Rautray, T.R., E-mail: trrautray@gmail.co [Ion Beam Laboratory, Institute of Physics, Bhubaneswar 751013, Orissa (India); Thirunavoukkarasu, M [Plant Biotechnology Lab, Institute of Minerals and Materials Technology (CSIR), Bhubaneswar 751013, Orissa (India); Chand, P.K., E-mail: pkchanduubot@yahoo.co.i [Plant Cell and Tissue culture Facility, Post-Graduate Department of Botany, Utkal University, Vani Vihar, Bhubaneswar 751004, Orissa (India)

    2010-12-15

    The multi-elemental composition of in vitro-proliferated root tissues of Andrographis paniculata (Burm.f.) Wall. ex Nees was compared with that of the naturally grown in vivo plants. Trace elements namely Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Rb, Sr and Pb in addition to two macro-elements K and Ca were identified and quantified in root tissues of both sources using the energy dispersive X-ray fluorescence (ED-XRF) technique. ED-XRF analysis was performed using Mo K X-rays generated from a secondary molybdenum target. The elemental content of in vitro roots was found to be at par with that of naturally grown plants of the same species. This opens up a possibility of exploiting in vitro root cultures as a viable, alternative and renewable source of phytochemicals of relevance, besides providing a means for conservation of the valuable natural resources.

  17. ED-XRF spectrometric analysis of comparative elemental composition of in vivo and in vitro roots of Andrographis paniculata (Burm.f.) Wall. ex Nees-a multi-medicinal herb

    International Nuclear Information System (INIS)

    Behera, P.R.; Nayak, P.; Barik, D.P.; Rautray, T.R.; Thirunavoukkarasu, M.; Chand, P.K.

    2010-01-01

    The multi-elemental composition of in vitro-proliferated root tissues of Andrographis paniculata (Burm.f.) Wall. ex Nees was compared with that of the naturally grown in vivo plants. Trace elements namely Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Rb, Sr and Pb in addition to two macro-elements K and Ca were identified and quantified in root tissues of both sources using the energy dispersive X-ray fluorescence (ED-XRF) technique. ED-XRF analysis was performed using Mo K X-rays generated from a secondary molybdenum target. The elemental content of in vitro roots was found to be at par with that of naturally grown plants of the same species. This opens up a possibility of exploiting in vitro root cultures as a viable, alternative and renewable source of phytochemicals of relevance, besides providing a means for conservation of the valuable natural resources.

  18. Downhole Elemental Analysis with LIBS

    Science.gov (United States)

    Moreschini, Paolo; Zacny, Kris; Rickman, Doug

    2011-01-01

    In this paper we discuss a novel instrument, currently under development at Honeybee Robotics with SBIR funding from NASA. The device is designed to characterize elemental composition as a function of depth in non-terrestrial geological formations. The instrument consists of a miniaturized laser-induced breakdown spectrometer (LIBS) analyzer integrated in a 2" diameter drill string. While the drill provides subsurface access, the LIBS analyzer provides information on the elemental composition of the borehole wall. This instrument has a variety of space applications ranging from exploration of the Moon for which it was originally designed, to Mars, as well as a variety of terrestrial applications. Subsurface analysis is usually performed by sample acquisition through a drill or excavator, followed by sample preparation and subsequent sample presentation to an instrument or suite of instruments. An alternative approach consisting in bringing a miniaturized version of the instrument to the sample has many advantages over the traditional methodology, as it allows faster response, reduced probability of cross-contamination and a simplification in the sampling mechanisms. LIBS functions by focusing a high energy laser on a material inducing a plasma consisting of a small fraction of the material under analysis. Optical emission from the plasma, analyzed by a spectrometer, can be used to determine elemental composition. A triangulation sensor located in the sensor head determines the distance of the sensor from the borehole wall. An actuator modifies the position of the sensor accordingly, in order to compensate for changes due to the profile of the borehole walls. This is necessary because LIBS measurements are negatively affected by changes in the relative position of the focus of the laser with respect to the position of the sample (commonly referred to as the "lens to sample distance"). Profiling the borehole is done by adjusting the position of the sensor with a

  19. Comparative risk analysis

    International Nuclear Information System (INIS)

    Niehaus, F.

    1988-01-01

    In this paper, the risks of various energy systems are discussed considering severe accidents analysis, particularly the probabilistic safety analysis, and probabilistic safety criteria, and the applications of these criteria and analysis. The comparative risk analysis has demonstrated that the largest source of risk in every society is from daily small accidents. Nevertheless, we have to be more concerned about severe accidents. The comparative risk analysis of five different energy systems (coal, oil, gas, LWR and STEC (Solar)) for the public has shown that the main sources of risks are coal and oil. The latest comparative risk study of various energy has been conducted in the USA and has revealed that the number of victims from coal is 42 as many than victims from nuclear. A study for severe accidents from hydro-dams in United States has estimated the probability of dam failures at 1 in 10,000 years and the number of victims between 11,000 and 260,000. The average occupational risk from coal is one fatal accident in 1,000 workers/year. The probabilistic safety analysis is a method that can be used to assess nuclear energy risks, and to analyze the severe accidents, and to model all possible accident sequences and consequences. The 'Fault tree' analysis is used to know the probability of failure of the different systems at each point of accident sequences and to calculate the probability of risks. After calculating the probability of failure, the criteria for judging the numerical results have to be developed, that is the quantitative and qualitative goals. To achieve these goals, several systems have been devised by various countries members of AIEA. The probabilistic safety ana-lysis method has been developed by establishing a computer program permit-ting to know different categories of safety related information. 19 tabs. (author)

  20. Trace Element Analysis of Selenium

    International Nuclear Information System (INIS)

    Soliman, M.S.A.

    2010-01-01

    The present thesis divided into four chapters as follows:Chapter (1):This chapter contains an introduction on different oxidation states of organic and inorganic species for selenium in environmental and biological samples, the process for separation of selenium from these samples and the importance of selenium as a component for these samples. Also gives notes about the techniques which are used in the elemental analysis for selenium species and the detection limits for selenium in these techniques, selenium species in human body and the importance of these species in protecting the body from the different types of cancer and the sources of selenium in environmental samples (soil and water) and distribution levels of selenium in these samples.Chapter (2):This chapter is divided into two parts :The first part deals with the sample collection process for environmental samples (underground water, soil) and the wet digestion ( microwave digestion ) process of soil samples. It also contains the theory of work of the closed microwave digestion system.The second part contains detailed information concerning the theoretical considerations of the used analytical techniques. These techniques include Hydride generation - Atomic Absorption Spectrometer (HG-AAS), Inductively Coupled Plasma Mass Spectrometer (ICP-MS) and Neutron Activation Analysis (NAA).Chapter (3): This chapter includes the methods of sampling, sample preparation, and sample digesition. The measures of quality assurance are disscused in this chapter. It describes in details the closed microwave digestion technique and the analytical methods used in this study which are present in Central Laboratory for Elemental and Isotopic Analysis (CLEIA) and the Egypt Second Research Reactor (ETRR-2). The described techniques are Atomic Absorption Spectrometer (AAS 6 vario, Analytical Jena GmbH, Germany), JMS-PLASMAX2 Mass Spectrometer (ICP-MS) and the Egypt Second Research Reactor (NAA).

  1. A comparative study on the stress distribution around dental implants in three arch form models for replacing six implants using finite element analysis.

    Science.gov (United States)

    Zarei, Maryam; Jahangirnezhad, Mahmoud; Yousefimanesh, Hojatollah; Robati, Maryam; Robati, Hossein

    2018-01-01

    Dental implant is a method to replacement of missing teeth. It is important for replacing the missed anterior teeth. In vitro method is a safe method for evaluation of stress distribution. Finite element analysis as an in vitro method evaluated stress distribution around replacement of six maxillary anterior teeth implants in three models of maxillary arch. In this in vitro study, using ABAQUS software (Simulia Corporation, Vélizy-Villacoublay, France), implant simulation was performed for reconstruction of six maxillary anterior teeth in three models. Two implants were placed on both sides of the canine tooth region (A model); two implants on both sides of the canine tooth region and another on one side of the central incisor region (B model); and two implants on both sides of the canine tooth region and two implants in the central incisor area (C model). All implants evaluated in three arch forms (tapered, ovoid, and square). Data were analyzed by finite analysis software. Von Mises stress by increasing of implant number was reduced. In a comparison of A model in each maxillary arch, the stress created in the cortical and cancellous bones in the square arch was less than ovoid and tapered arches. The stress created in implants and cortical and cancellous bones in C model was less than A and B models. The C model (four-implant) reduced the stress distribution in cortical and cancellous bones, but this pattern must be evaluated according to arch form and cost benefit of patients.

  2. Finite element analysis of ARPS structures

    International Nuclear Information System (INIS)

    Ruhkamp, J.D.; McDougal, J.R.; Kramer, D.P.

    1998-01-01

    Algor finite element software was used to determine the stresses and deflections in the metallic walls of Advanced Radioisotope Power Systems (ARPS) designs. The preliminary design review of these systems often neglects the structural integrity of the design which can effect fabrication and the end use of the design. Before finite element analysis (FEA) was run on the canister walls of the thermophotovoltaic (TPV) generator, hand calculations were used to approximate the stresses and deflections in a flat plate. These results compared favorably to the FEA results of a similar size flat plate. The AMTEC (Alkali Metal Thermal-to-Electric Conversion) cells were analyzed by FEA and the results compared to two cells that were mechanically tested. The mechanically tested cells buckled in the thin sections, one at the top and one in the lower section. The FEA predicted similar stress and shape results but the critical buckling load was found to be very shape dependent

  3. Finite element analysis of inelastic structural behavior

    International Nuclear Information System (INIS)

    Argyris, J.H.; Szimmat, J.; Willam, K.J.

    1977-01-01

    The paper describes recent achievements in the finite element analysis of inelastic material behavior. The main purpose is to examine the interaction of three disciplines; (i) the finite element formulation of large deformation problems in the light of a systematic linearization, (ii) the constitutive modelling of inelastic processes in the rate-dependent and rate-independent response regime and (iii) the numerical solution of nonlinear rate problems via incremental iteration techniques. In the first part, alternative finite element models are developed for the idealization of large deformation problems. A systematic approach is presented to linearize the field equations locally by an incremental procedure. The finite element formulation is then examined for the description of inelastic material processes. In the second part, nonlinear and inelastic material phenomena are classified and illustrated with representative examples of concrete and metal components. In particular, rate-dependent and rate-independent material behavior is examined and representative constitutive models are assessed for their mathematical characterization. Hypoelastic, elastoplastic and endochronic models are compared for the description rate-independent material phenomena. In the third part, the numerial solution of inelastic structural behavior is discussed. In this context, several incremental techniques are developed and compared for tracing the evolution of the inelastic process. The numerical procedures are examined with regard to stability and accuracy to assess the overall efficiency. The 'optimal' incremental technique is then contrasted with the computer storage requirements to retain the data for the 'memory-characteristics' of the constitutive model

  4. Phytochemical screening, proximate and elemental analysis of ...

    African Journals Online (AJOL)

    Citrus sinensis was screened for its phytochemical composition and was evaluated for the proximate and elemental analysis. The phytochemical analysis indicated the presence of reducing sugar, saponins, cardiac glycosides, tannins and flavonoids. The elemental analysis indicated the presence of the following mineral ...

  5. Instrumental trace element analysis of California market milk

    International Nuclear Information System (INIS)

    Ragaini, R.C.; Langhorst, A.L.; Ralston, H.R.; Heft, R.

    1975-01-01

    Trace element analysis for 15 elements (Zn, Na, Br, Rb, Sr, Mg, Al, Ca, Cl, I, K, Fe, Co, Se, Cs) was carried out on 32 samples of California market milk and 6 samples of Colorado milk in a pilot study of toxic and nutrient trace elements in the soil-forage-cow-milk food chain. The techniques of instrumental neutron activation analysis and x-ray fluorescence analysis are described. Sample collection, preparation, analysis, and data reduction procedures are discussed. The mean values and variations of trace element concentrations in milk are compared to data from other studies. (U.S.)

  6. FINITE ELEMENT ANALYSIS OF STRUCTURES

    Directory of Open Access Journals (Sweden)

    PECINGINA OLIMPIA-MIOARA

    2015-05-01

    Full Text Available The application of finite element method is analytical when solutions can not be applied for deeper study analyzes static, dynamic or other types of requirements in different points of the structures .In practice it is necessary to know the behavior of the structure or certain parts components of the machine under the influence of certain factors static and dynamic . The application of finite element in the optimization of components leads to economic growth , to increase reliability and durability organs studied, thus the machine itself.

  7. Comparative analysis of metal samples

    International Nuclear Information System (INIS)

    Lopez M, J.; Ramirez T, J.J.; Sandoval J, A.R.; Villasenor S, P.; Aspiazu F, J.A.

    2001-01-01

    Metal wastes were analysed to establish its origin with respect to a set of pieces. The elemental analysis was realized using the PIXE technique (Proton induced X-ray emission). Results are presented. (Author)

  8. Why do probabilistic finite element analysis ?

    CERN Document Server

    Thacker, Ben H

    2008-01-01

    The intention of this book is to provide an introduction to performing probabilistic finite element analysis. As a short guideline, the objective is to inform the reader of the use, benefits and issues associated with performing probabilistic finite element analysis without excessive theory or mathematical detail.

  9. Determination of some main elements and traces by x-ray fluorescence analysis in silicate rocks: a comparative study of two analytical techniques

    International Nuclear Information System (INIS)

    Andrade, M.D. de.

    1977-01-01

    The determinations of silicon, magnesium, iron, potassium, calcium, titanium, manganese, barium, strontium, rubidium, zirconium and scandium in felsic and mafic rocks, by X ray fluorescence analysis are presented. (author)

  10. Elements of stock market analysis

    Directory of Open Access Journals (Sweden)

    Suciu, T.

    2013-12-01

    Full Text Available The paper represents a starting point in the presentation of the two types of stock/market analysis: the fundamental analysis and the technical analysis. The fundamental analysis consist in the assessment of the financial and economic status of the company together with the context and macroeconomic environment where it activates. The technical analysis deals with the demand and supply of securities and the evolution of their trend on the market, using a range of graphics and charts to illustrate the market tendencies for the quick identification of the best moments to buy or sell.

  11. Finite element application to global reactor analysis

    International Nuclear Information System (INIS)

    Schmidt, F.A.R.

    1981-01-01

    The Finite Element Method is described as a Coarse Mesh Method with general basis and trial functions. Various consequences concerning programming and application of Finite Element Methods in reactor physics are drawn. One of the conclusions is that the Finite Element Method is a valuable tool in solving global reactor analysis problems. However, problems which can be described by rectangular boxes still can be solved with special coarse mesh programs more efficiently. (orig.) [de

  12. A computer program for structural analysis of fuel elements

    International Nuclear Information System (INIS)

    Hayashi, I.M.V.; Perrotta, J.A.

    1988-01-01

    It's presented the code ELCOM for the matrix analysis of tubular structures coupled by rigid spacers, typical of PWR's fuel elements. The code ELCOM makes a static structural analysis, where the displacements and internal forces are obtained for each structure at the joints with the spacers, and also, the natural frequencies and vibrational modes of an equivalent integrated structure are obtained. The ELCOM result is compared to a PWR fuel element structural analysis obtained in published paper. (author) [pt

  13. Finite element analysis of tibial fractures

    DEFF Research Database (Denmark)

    Wong, Christian Nai En; Mikkelsen, Mikkel Peter W; Hansen, Leif Berner

    2010-01-01

    Project. The data consisted of 21,219 3D elements with a cortical shell and a trabecular core. Three types of load of torsion, a direct lateral load and axial compression were applied. RESULTS: The finite element linear static analysis resulted in relevant fracture localizations and indicated relevant...

  14. Finite element analysis of piezoelectric materials

    International Nuclear Information System (INIS)

    Lowrie, F.; Stewart, M.; Cain, M.; Gee, M.

    1999-01-01

    This guide is intended to help people wanting to do finite element analysis of piezoelectric materials by answering some of the questions that are peculiar to piezoelectric materials. The document is not intended as a complete beginners guide for finite element analysis in general as this is better dealt with by the individual software producers. The guide is based around the commercial package ANSYS as this is a popular package amongst piezoelectric material users, however much of the information will still be useful to users of other finite element codes. (author)

  15. Neutron activation analysis of trace elements in IAEA reference materials

    International Nuclear Information System (INIS)

    Cheema, M.N.; Hasany, S.M.; Hanif, I.; Chaudhry, M.S.; Qureshi, I.H.

    1978-09-01

    Analytical Chemistry Group of Nuclear Chemistry Division at PINSTECH has been participating in IAEA Intercomparison programme of analytical quality control since 1972. So far fifteen samples of a variety of materials received from the Agency have been analyzed for different minor and trace elements. Mostly destructive and non-destructive neutron activation analysis techniques have been used for elemental analysis. In this report the description of the samples and the experimental procedures employed have been mentioned. The results of elemental analysis have been reported and compared with IAEA values which are based on the average computed from the results of different participating laboratories. (authors)

  16. Alphavirus replicon approach to promoterless analysis of IRES elements.

    Science.gov (United States)

    Kamrud, K I; Custer, M; Dudek, J M; Owens, G; Alterson, K D; Lee, J S; Groebner, J L; Smith, J F

    2007-04-10

    Here we describe a system for promoterless analysis of putative internal ribosome entry site (IRES) elements using an alphavirus (family Togaviridae) replicon vector. The system uses the alphavirus subgenomic promoter to produce transcripts that, when modified to contain a spacer region upstream of an IRES element, allow analysis of cap-independent translation of genes of interest (GOI). If the IRES element is removed, translation of the subgenomic transcript can be reduced >95% compared to the same transcript containing a functional IRES element. Alphavirus replicons, used in this manner, offer an alternative to standard dicistronic DNA vectors or in vitro translation systems currently used to analyze putative IRES elements. In addition, protein expression levels varied depending on the spacer element located upstream of each IRES. The ability to modulate the level of expression from alphavirus vectors should extend the utility of these vectors in vaccine development.

  17. Nonlinear finite element analysis of concrete structures

    International Nuclear Information System (INIS)

    Ottosen, N.S.

    1980-05-01

    This report deals with nonlinear finite element analysis of concrete structures loaded in the short-term up until failure. A profound discussion of constitutive modelling on concrete is performed; a model, applicable for general stress states, is described and its predictions are compared with experimental data. This model is implemented in the AXIPLANE-program applicable for axisymmetrick and plane structures. The theoretical basis for this program is given. Using the AXIPLANE-program various concrete structures are analysed up until failure and compared with experimental evidence. These analyses include panels pressure vessel, beams failing in shear and finally a specific pull-out test, the Lok-Test, is considered. In these analyses, the influence of different failure criteria, aggregate interlock, dowel action, secondary cracking, magnitude of compressive strenght, magnitude of tensile strenght and of different post-failure behaviours of the concrete are evaluated. Moreover, it is shown that a suitable analysis of the theoretical data results in a clear insight into the physical behaviour of the considered structures. Finally, it is demonstrated that the AXISPLANE-program for widely different structures exhibiting very delicate structural aspects gives predictions that are in close agreement with experimental evidence. (author)

  18. ANSYS mechanical APDL for finite element analysis

    CERN Document Server

    Thompson, Mary Kathryn

    2017-01-01

    ANSYS Mechanical APDL for Finite Element Analysis provides a hands-on introduction to engineering analysis using one of the most powerful commercial general purposes finite element programs on the market. Students will find a practical and integrated approach that combines finite element theory with best practices for developing, verifying, validating and interpreting the results of finite element models, while engineering professionals will appreciate the deep insight presented on the program's structure and behavior. Additional topics covered include an introduction to commands, input files, batch processing, and other advanced features in ANSYS. The book is written in a lecture/lab style, and each topic is supported by examples, exercises and suggestions for additional readings in the program documentation. Exercises gradually increase in difficulty and complexity, helping readers quickly gain confidence to independently use the program. This provides a solid foundation on which to build, preparing readers...

  19. Finite elements for analysis and design

    CERN Document Server

    Akin, J E; Davenport, J H

    1994-01-01

    The finite element method (FEM) is an analysis tool for problem-solving used throughout applied mathematics, engineering, and scientific computing. Finite Elements for Analysis and Design provides a thoroughlyrevised and up-to-date account of this important tool and its numerous applications, with added emphasis on basic theory. Numerous worked examples are included to illustrate the material.Key Features* Akin clearly explains the FEM, a numerical analysis tool for problem-solving throughout applied mathematics, engineering and scientific computing* Basic theory has bee

  20. Trace element analysis in soy sauce. 2

    International Nuclear Information System (INIS)

    Haruyama, Yoichi; Saito, Manabu; Tomita, Michio; Yoshida, Koji.

    1994-01-01

    Trace elements in four kinds of soybean and three kinds of salt have been measured by means of in-air PIXE. In soybeans, which were made in Japan, America, Canada and China, six kinds of trace elements were detected, such as Mn, Fe, Ni, Cu, Zn and Br. The concentration of these elements varied depending on the place they were made. American soybean showed characteristic feature compared with other soybeans. As to the bromine concentration, American soybean contains ten times as much as Japanese one. In salts Br and Sr were detected. (author)

  1. Electrical machine analysis using finite elements

    CERN Document Server

    Bianchi, Nicola

    2005-01-01

    OUTLINE OF ELECTROMAGNETIC FIELDSVector AnalysisElectromagnetic FieldsFundamental Equations SummaryReferencesBASIC PRINCIPLES OF FINITE ELEMENT METHODSIntroductionField Problems with Boundary ConditionsClassical Method for the Field Problem SolutionThe Classical Residual Method (Galerkin's Method)The Classical Variational Method (Rayleigh-Ritz's Method)The Finite Element MethodReferencesAPPLICATIONS OF THE FINITE ELEMENT METHOD TO TWO-DIMENSIONAL FIELDSIntroductionLinear Interpolation of the Function fApplication of the Variational MethodSimple Descriptions of Electromagnetic FieldsAppendix: I

  2. Elemental analysis techniques using proton microbeam

    International Nuclear Information System (INIS)

    Sakai, Takuro; Oikawa, Masakazu; Sato, Takahiro

    2005-01-01

    Proton microbeam is a powerful tool for two-dimensional elemental analysis. The analysis is based on Particle Induced X-ray Emission (PIXE) and Particle Induced Gamma-ray Emission (PIGE) techniques. The paper outlines the principles and instruments, and describes the dental application has been done in JAERI Takasaki. (author)

  3. Trace element analysis of nail polishes

    International Nuclear Information System (INIS)

    Misra, G.; Mittal, V.K.; Sahota, H.S.

    1999-01-01

    Instrumental neutron activation analysis (INAA) technique was used to measure the concentrations of various trace elements in nail polishes of popular Indian and foreign brands. The aim of the present experiment was to see whether trace elements could distinguish nail polishes of different Indian and foreign brands from forensic point of view. It was found that cesium can act as a marker to differentiate foreign and Indian brands. (author)

  4. Chemical analysis of rare earth elements

    International Nuclear Information System (INIS)

    Tsukahara, Ryoichi; Sakoh, Takefumi; Nagai, Iwao

    1994-01-01

    Recently attention has been paid to ICP-AES or ICP-MS, and the reports on the analysis of rare earth elements by utilizing these methods continue to increase. These reports have become to take about 30% of the reports on rare earth analysis, and this is because these methods are highly sensitive to rare earth elements, and also these methods have spread widely. In ICP-AES and ICP-MS, mostly solution samples are measured, therefore, solids must be made into solution. At the time of quantitatively determining the rare earth elements of low concentration, separation and concentration are necessary. Referring to the literatures reported partially in 1990 and from 1991 to 1993, the progress of ICP-AES and ICP-MS is reported. Rare earth oxides and the alloys containing rare earth elements are easily decomposed with acids, but the decomposition of rocks is difficult, and its method is discussed. The separation of the rare earth elements from others in geochemical samples, cation exchange process is frequently utilized. Also solvent extraction process has been studied. For the separation of rare earth elements mutually, chromatography is used. The spectral interference in spectral analysis was studied. The comparison of these methods with other methods is reported. (K.I)

  5. Neutron activation analysis-comparative (NAAC)

    International Nuclear Information System (INIS)

    Zimmer, W.H.

    1979-01-01

    A software system for the reduction of comparative neutron activation analysis data is presented. Libraries are constructed to contain the elemental composition and isotopic nuclear data of an unlimited number of standards. Ratios to unknown sample data are performed by standard calibrations. Interfering peak corrections, second-order activation-product corrections, and deconvolution of multiplets are applied automatically. Passive gamma-energy analysis can be performed with the same software. 3 figures

  6. Elemental analysis of biological materials. Current problems and techniques with special reference to trace elements

    International Nuclear Information System (INIS)

    1980-01-01

    Selected techniques were reviewed for the assay of trace and minor elements in biological materials. Other relevant information is also presented on the need for such analyses, sampling, sample preparation and analytical quality control. In order to evaluate and compare the applicability of the various analytical techniques on a meaningful and objective basis, the materials chosen for consideration were intended to be typical of a wide range of biological matrics of different elemental compositions, namely Bowen's kale, representing a plant material, and NBS bovine liver, IAEA animal muscle, and blood serum, representing animal tissues. The subject is reviewed under the following headings: on the need for trace element analyses in the life sciences (4 papers); sampling and sample preparation for trace element analysis (2 papers); analytical techniques for trace and minor elements in biological materials (7 papers); analytical quality control (2 papers)

  7. PIXE - a new method for elemental analysis

    International Nuclear Information System (INIS)

    Johansson, S.A.E.

    1983-01-01

    With elemental analysis we mean the determination of which chemical elements are present in a sample and of their concentration. This is an old and important problem in chemistry. The earliest methods were purely chemical and many such methods are still used. However, various methods based on physical principles have gradually become more and more important. One such method is neutron activation. When the sample is bombarded with neutrons it becomes radioactive and the various radioactive isotopes produced can be identified by the radiation they emit. From the measured intensity of the radiation one can calculate how much of a certain element that is present in the sample. Another possibility is to study the light emitted when the sample is excited in various ways. A spectroscopic investigation of the light can identify the chemical elements and allows also a determination of their concentration in the sample. In the same way, if a sample can be brought to emit X-rays, this radiation is also characteristic for the elements present and can be used to determine the elemental concentration. One such X-ray method which has been developed recently is PIXE. The name is an acronym for Particle Induced X-ray Emission and indicates the principle of the method. Particles in this context means heavy, charged particles such as protons and a-particles of rather high energy. Hence, in PIXE-analysis the sample is irradiated in the beam of an accelerator and the emitted X-rays are studied. (author)

  8. Analysis of light elements by PIGE

    International Nuclear Information System (INIS)

    Kim, Y. S.; Choi, H. W.; Kim, D. K.; Woo, H. J.; Kim, N. B.; Park, K. S.

    2000-01-01

    The PIGE (Proton Induced Gamma ray Emission) method was applied for the measurement of light elements Li - K. A test measurement has been performed for geological, biological, environmental and material samples by using a standard sample for each element. The measurement was performed for the two proton energies of 2.4 and 3.4 MeV, and 3.4MeV was found to yield better result for multielemental analysis. The result shows a fair agreement within 15% for all elements with standard values. The detection limits of Li, B, F and Na are less than 100 ppm, while those of the other elements are from a few hundred ppm to a few percents. (author)

  9. Single cell elemental analysis using nuclear microscopy

    International Nuclear Information System (INIS)

    Ren, M.Q.; Thong, P.S.P.; Kara, U.; Watt, F.

    1999-01-01

    The use of Particle Induced X-ray Emission (PIXE), Rutherford Backscattering Spectrometry (RBS) and Scanning Transmission Ion Microscopy (STIM) to provide quantitative elemental analysis of single cells is an area which has high potential, particularly when the trace elements such as Ca, Fe, Zn and Cu can be monitored. We describe the methodology of sample preparation for two cell types, the procedures of cell imaging using STIM, and the quantitative elemental analysis of single cells using RBS and PIXE. Recent work on single cells at the Nuclear Microscopy Research Centre,National University of Singapore has centred around two research areas: (a) Apoptosis (programmed cell death), which has been recently implicated in a wide range of pathological conditions such as cancer, Parkinson's disease etc, and (b) Malaria (infection of red blood cells by the malaria parasite). Firstly we present results on the elemental analysis of human Chang liver cells (ATTCC CCL 13) where vanadium ions were used to trigger apoptosis, and demonstrate that nuclear microscopy has the capability of monitoring vanadium loading within individual cells. Secondly we present the results of elemental changes taking place in individual mouse red blood cells which have been infected with the malaria parasite and treated with the anti-malaria drug Qinghaosu (QHS)

  10. Comparative research of finite element methods for perforated structures of nuclear power plant primary equipment

    International Nuclear Information System (INIS)

    Xiong Guangming; Deng Xiaoyun; Jin Ting

    2013-01-01

    Many perforated structures are used for nuclear power plant primary equipment, and they are complex, and have various forms. In order to explore the analysis and evaluation method, this paper used finite element method and equivalent analytic method to do the comparative analysis of perforated structures. The paper considered the main influence factors (including perforated forms, arrangements, and etc.), obtaining the systematic analysis methods of perforated structures. (authors)

  11. BLSSpeller: exhaustive comparative discovery of conserved cis-regulatory elements.

    Science.gov (United States)

    De Witte, Dieter; Van de Velde, Jan; Decap, Dries; Van Bel, Michiel; Audenaert, Pieter; Demeester, Piet; Dhoedt, Bart; Vandepoele, Klaas; Fostier, Jan

    2015-12-01

    The accurate discovery and annotation of regulatory elements remains a challenging problem. The growing number of sequenced genomes creates new opportunities for comparative approaches to motif discovery. Putative binding sites are then considered to be functional if they are conserved in orthologous promoter sequences of multiple related species. Existing methods for comparative motif discovery usually rely on pregenerated multiple sequence alignments, which are difficult to obtain for more diverged species such as plants. As a consequence, misaligned regulatory elements often remain undetected. We present a novel algorithm that supports both alignment-free and alignment-based motif discovery in the promoter sequences of related species. Putative motifs are exhaustively enumerated as words over the IUPAC alphabet and screened for conservation using the branch length score. Additionally, a confidence score is established in a genome-wide fashion. In order to take advantage of a cloud computing infrastructure, the MapReduce programming model is adopted. The method is applied to four monocotyledon plant species and it is shown that high-scoring motifs are significantly enriched for open chromatin regions in Oryza sativa and for transcription factor binding sites inferred through protein-binding microarrays in O.sativa and Zea mays. Furthermore, the method is shown to recover experimentally profiled ga2ox1-like KN1 binding sites in Z.mays. BLSSpeller was written in Java. Source code and manual are available at http://bioinformatics.intec.ugent.be/blsspeller Klaas.Vandepoele@psb.vib-ugent.be or jan.fostier@intec.ugent.be. Supplementary data are available at Bioinformatics online. © The Author 2015. Published by Oxford University Press.

  12. Orthodontic treatment: Introducing finite element analysis

    NARCIS (Netherlands)

    Driel, W.D. van; Leeuwen, E.J. van

    1998-01-01

    The aim of orthodontic treatment is the displacement of teeth by means ofspecial appliances, like braces and brackets. Through these appliances the orthodontist can apply a set of forces to the teeth which wilt result in its displacement through the jawbone. Finite Element analysis of this process

  13. Uncertainties in elemental quantitative analysis by PIXE

    International Nuclear Information System (INIS)

    Montenegro, E.C.; Baptista, G.B.; Paschoa, A.S.; Barros Leite, C.V.

    1979-01-01

    The effects of the degree of non-uniformity of the particle beam, matrix composition and matrix thickness in a quantitative elemental analysis by particle induced X-ray emission (PIXE) are discussed and a criterion to evaluate the resulting degree of uncertainty in the mass determination by this method is established. (Auth.)

  14. Isogeometric finite element analysis of poroelasticity

    NARCIS (Netherlands)

    Irzal, F.; Remmers, J.J.C.; Verhoosel, C.V.; Borst, de R.

    2013-01-01

    We present an alternative numerical approach for predicting the behaviour of a deformable fluid-saturated porous medium. The conventional finite element technology is replaced by isogeometric analysis that uses non-uniform rational B-splines. The ability of these functions to provide higher-order

  15. Upstand Finite Element Analysis of Slab Bridges

    OpenAIRE

    O'Brien, Eugene J.; Keogh, D.L.

    1998-01-01

    For slab bridge decks with wide transverse edge cantilevers, the plane grillage analogy is shown to be an inaccurate method of linear elastic analysis due to variations in the vertical position of the neutral axis. The upstand grillage analogy is also shown to give inaccurate results, this time due to inappropriate modelling of in-plane distortions. An alternative method, known as upstand finite element analysis, is proposed which is sufficiently simple to be used on an everyday basis in the ...

  16. A Comparative SEM-EDS Elemental Composition of Mud in Coastal ...

    African Journals Online (AJOL)

    The present study was aimed to understand the comparative abundance and source of elemental constituents in mud of four coastal shrimp farming areas, Vunh Tau (VT), Nha Trang (NT), Da Nang (DN) and Hue (HU) in Viet Nam using SEM-EDS analysis. Mud samples were collected from shrimp farming coastal zones ...

  17. Trace elements in termites by PIXE analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yoshimura, T. E-mail: tsuyoshi@termite.kuwri.kyoto-u.ac.jp; Kagemori, N.; Kawai, S.; Sera, K.; Futatsugawa, S

    2002-04-01

    Trace elements in a Japanese subterranean xylophagous termite, Coptotermes formosanus Shiraki, were analyzed by the PIXE method. The total amount of the 14 predominant elements out of 27 detected in an intact termite was higher in a soldier termite (23 000 {mu}g/g) than in a worker termite (10 000 {mu}g/g). A block of wood (Pinus densiflora Sieb. et Zucc.) for termite feed had a much lower concentration (3600 {mu}g/g) compared with that in an intact termite. This probably relates the functional bio-condensation and/or bio-recycling of trace elements in C. formosanus. When a termite was separated into three anatomical parts, head, degutted body and gut, the worker gut contained the highest total amount of the 14 predominant measured elements (31 000 {mu}g/g). This might be correlated with the higher activity of food digestion and energy production in the worker gut. Moreover, the mandible of the soldier head, with an exoskeleton that is intensely hardened, showed a preferential distribution of Mn and Fe. These results suggest that the characteristic localization of elements will be closely related to the functional role of the individual anatomical part of C. formosanus.

  18. Structural analysis of reactor fuel elements

    International Nuclear Information System (INIS)

    Weeks, R.W.

    1977-01-01

    An overview of fuel-element modeling is presented that traces the development of codes for the prediction of light-water-reactor and fast-breeder-reactor fuel-element performance. It is concluded that although the mathematical analysis is now far advanced, the development and incorporation of mechanistic constitutive equations has not kept pace. The resultant reliance on empirical correlations severely limits the physical insight that can be gained from code extrapolations. Current efforts include modeling of alternate fuel systems, analysis of local fuel-cladding interactions, and development of a predictive capability for off-normal behavior. Future work should help remedy the current constitutive deficiencies and should include the development of deterministic failure criteria for use in design

  19. Introduction to nonlinear finite element analysis

    CERN Document Server

    Kim, Nam-Ho

    2015-01-01

    This book introduces the key concepts of nonlinear finite element analysis procedures. The book explains the fundamental theories of the field and provides instructions on how to apply the concepts to solving practical engineering problems. Instead of covering many nonlinear problems, the book focuses on three representative problems: nonlinear elasticity, elastoplasticity, and contact problems. The book is written independent of any particular software, but tutorials and examples using four commercial programs are included as appendices: ANSYS, NASTRAN, ABAQUS, and MATLAB. In particular, the MATLAB program includes all source codes so that students can develop their own material models, or different algorithms. This book also: ·         Presents clear explanations of nonlinear finite element analysis for elasticity, elastoplasticity, and contact problems ·         Includes many informative examples of nonlinear analyses so that students can clearly understand the nonlinear theory ·    ...

  20. Elemental analysis of hair using PIXE-tomography and INAA

    International Nuclear Information System (INIS)

    Beasley, D.; Gomez-Morilla, I.; Spyrou, N.

    2008-01-01

    3D quantitative elemental maps of a section of a strand of hair were produced using a combination of PIXE-Tomography and simultaneous On/Off Axis STIM-Tomography at the University of Surrey Ion Beam Centre. The distributions of S, K, Cl, Ca, Fe and Zn were determined using the PIXE-T reconstruction package DISRA. The results were compared with conventional bulk PIXE analysis of tomographic data as determined using Dan32. The overall concentrations determined by PIXE were compared with elemental concentrations held in the University of Surrey Hair Database. All the entries currently in the database were produced using INAA. The merits and possible contributions of tomographic PIXE analysis to analysis of hair are discussed. The conclusions drawn from the PIXE-Tomography analysis can be used to argue for more stringent procedures for hair analysis at the University of Surrey. (author)

  1. Comparative Evaluation of a Four-Implant-Supported Polyetherketoneketone Framework Prosthesis: A Three-Dimensional Finite Element Analysis Based on Cone Beam Computed Tomography and Computer-Aided Design.

    Science.gov (United States)

    Lee, Ki-Sun; Shin, Sang-Wan; Lee, Sang-Pyo; Kim, Jong-Eun; Kim, Jee-Hwan; Lee, Jeong-Yol

    The purpose of this pilot study was to evaluate and compare polyetherketoneketone (PEKK) with different framework materials for implant-supported prostheses by means of a three-dimensional finite element analysis (3D-FEA) based on cone beam computed tomography (CBCT) and computer-aided design (CAD) data. A geometric model that consisted of four maxillary implants supporting a prosthesis framework was constructed from CBCT and CAD data of a treated patient. Three different materials (zirconia, titanium, and PEKK) were selected, and their material properties were simulated using FEA software in the generated geometric model. In the PEKK framework (ie, low elastic modulus) group, the stress transferred to the implant and simulated adjacent tissue was reduced when compressive stress was dominant, but increased when tensile stress was dominant. This study suggests that the shock-absorbing effects of a resilient implant-supported framework are limited in some areas and that rigid framework material shows a favorable stress distribution and safety of overall components of the prosthesis.

  2. Finite element analysis of nonlinear creeping flows

    International Nuclear Information System (INIS)

    Loula, A.F.D.; Guerreiro, J.N.C.

    1988-12-01

    Steady-state creep problems with monotone constitutive laws are studied. Finite element approximations are constructed based on mixed Petrov-Galerkin formulations for constrained problems. Stability, convergence and a priori error estimates are proved for equal-order discontinuous stress and continuous velocity interpolations. Numerical results are presented confirming the rates of convergence predicted in the analysis and the good performance of this formulation. (author) [pt

  3. Trace-element analysis in environmental sciences

    International Nuclear Information System (INIS)

    Valkovic, V.; Moschini, G.

    1988-01-01

    The use of charged-particle accelerators in trace-element analysis in the field of environmental sciences is described in this article. Nuclear reactions, charged-particle-induced X-ray emission as well as other nuclear and atomic processes can be used individually, or combined, in developing adequate analytical systems. In addition to concentration levels, concentration levels, concentration profiles can be measured, resulting in unique information. Some examples of experiments performed are described together with the suggestions for future measurements [pt

  4. Neutron activation analysis as an element of sculpture provenance establishing

    International Nuclear Information System (INIS)

    Panczyk, E.; Rowinska, L.; Walis, L.; Ligeza, M.; Nalepa, B.

    1998-01-01

    Investigation was carried out on the subject named ''Madonna Jackowa'' (XV cent.). The investigation object was to answer whether ''Madonna Jackowa'' was made of a native alabaster. Alabaster derived from five carious mines situated at the Cracow - Lvov line and ''Madonna Jackowa'' were analysed and the trace elements contents were compared. Instrumental neutron activation method was used for analysis of the trace. (author)

  5. Three-dimensional wake field analysis by boundary element method

    International Nuclear Information System (INIS)

    Miyata, K.

    1987-01-01

    A computer code HERTPIA was developed for the calculation of electromagnetic wake fields excited by charged particles travelling through arbitrarily shaped accelerating cavities. This code solves transient wave problems for a Hertz vector. The numerical analysis is based on the boundary element method. This program is validated by comparing its results with analytical solutions in a pill-box cavity

  6. Analytical and statistical analysis of elemental composition of lichens

    International Nuclear Information System (INIS)

    Calvelo, S.; Baccala, N.; Bubach, D.; Arribere, M.A.; Riberio Guevara, S.

    1997-01-01

    The elemental composition of lichens from remote southern South America regions has been studied with analytical and statistical techniques to determine if the values obtained reflect species, growth forms or habitat characteristics. The enrichment factors are calculated discriminated by species and collection site and compared with data available in the literature. The elemental concentrations are standardized and compared for different species. The information was statistically processed, a cluster analysis was performed using the three first principal axes of the PCA; the three groups formed are presented. Their relationship with the species, collection sites and the lichen growth forms are interpreted. (author)

  7. Analysis of trace elements in human hair by PIXE

    International Nuclear Information System (INIS)

    Baptista, G.B.; Montenegro, E.C.; Paschoa, A.S.; Barros Leite, C.V. de.

    1980-10-01

    The PIXE method was applied to the analysis of trace elements in scalp hair using two methods for target preparation. In the first method eigth hair strands each with nearly cylindrical geommetry and approximately the same diameter were selected and placed on an aluminum frame. In the second method a given mass of hair was dissolved with nitric acid and a known amount of strontium was added to the solution and dripped on a membrane filter using a micropipet. The results for the concentrations of trace elements in hair obtained by the two methods are compared and several aspects of the analysis is discussed. (Author) [pt

  8. Application of synchrotron radiation to elemental analysis

    International Nuclear Information System (INIS)

    Jones, K.W.; Gordon, B.M.; Hanson, A.L.; Hastings, J.B.; Howells, M.R.; Kraner, H.W.; Chen, J.R.

    1983-01-01

    The use of a synchrotron storage ring as a high brightness source for production of monoergic, variable energy, and highly polarized x-ray beams promises to revolutionize the field of elemental analysis. The results of exploratory work using the Cornell synchrotron facility, CHESS, will be described. Design considerations and features of the new X-Ray Microprobe Facility now under construction at the Brookhaven National Synchrotron Light Source will be presented. This facility will be used for bulk analysis and for microanalysis with an initial spatial resolution of the order of 30 μm

  9. Network application of PIXE trace element analysis

    International Nuclear Information System (INIS)

    Niizeki, T.; Kawasaki, K.; Hattori, T.

    2003-01-01

    Particle Induced X-ray Emission (PIXE) is a very sensitive analytical technique for determinations of trace elements. But the number of users is limited because there are not so much accelerators which can be used easily. On the other hand, PIXE is a typical machine analysis which can easily analyze automatically and make online data acquisition system. If there is useful online data handling system then PIXE analysis should be more useful for many persons. Therefore we develop to online PIXE facility at Tokyo Institute of Technology VdG laboratory and use it for environmental educations. (author)

  10. Complex finite element sensitivity method for creep analysis

    International Nuclear Information System (INIS)

    Gomez-Farias, Armando; Montoya, Arturo; Millwater, Harry

    2015-01-01

    The complex finite element method (ZFEM) has been extended to perform sensitivity analysis for mechanical and structural systems undergoing creep deformation. ZFEM uses a complex finite element formulation to provide shape, material, and loading derivatives of the system response, providing an insight into the essential factors which control the behavior of the system as a function of time. A complex variable-based quadrilateral user element (UEL) subroutine implementing the power law creep constitutive formulation was incorporated within the Abaqus commercial finite element software. The results of the complex finite element computations were verified by comparing them to the reference solution for the steady-state creep problem of a thick-walled cylinder in the power law creep range. A practical application of the ZFEM implementation to creep deformation analysis is the calculation of the skeletal point of a notched bar test from a single ZFEM run. In contrast, the standard finite element procedure requires multiple runs. The value of the skeletal point is that it identifies the location where the stress state is accurate, regardless of the certainty of the creep material properties. - Highlights: • A novel finite element sensitivity method (ZFEM) for creep was introduced. • ZFEM has the capability to calculate accurate partial derivatives. • ZFEM can be used for identification of the skeletal point of creep structures. • ZFEM can be easily implemented in a commercial software, e.g. Abaqus. • ZFEM results were shown to be in excellent agreement with analytical solutions

  11. Comparative study of the suitability of two lichen species for trace element atmospheric monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Saiki, Mitiko; Alves, Edson R.; Genezini, Frederico A., E-mail: mitiko@ipen.br, E-mail: eralves@ipen.br, E-mail: fredzini@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN-SP), Sao Paulo, SP (Brazil); Saldiva, Paulo H.N., E-mail: pepino@usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Faculdade de Medicina

    2013-07-01

    Lichens have been widely used in monitoring studies. Consequently, it is very useful to study the suitability of lichen species to monitor pollutants allowing in this way the best choice. The aim of this study was to compare the accumulation of trace elements by two epiphytic lichen species Canoparmelia texana (Tuck) Elix and Hale and Usnea amblyoclada (Mull. Arg.) Zahlbr. Five samples of each species were collected during the period from November 2010 in a same site far from downtown Sao Paulo city. Lichens collected from tree barks were cleaned, freeze-dried, ground and analyzed by neutron activation analysis. Aliquots of lichen samples and synthetic elemental standards were irradiated at the IEA-R1 nuclear research reactor. The induced gamma activities were measured using a hyperpure Ge detector coupled to a digital spectrum analyzer. Concentrations of As, Ba, Cd, Cr, Cs, Fe, Mg, Mn, Na, Rb, V and Zn were determined in both lichen species. The results demonstrated that both species can be used for evaluating air quality. The element concentrations showed difference between lichen species and also among their sampling periods. These differences may be attributed to the distinct mechanisms of element absorption by lichens as well as various other factors that affect their element accumulation. The comparative evaluation made calculating the ratios between C. texana species sample and that in Usnea amblyoclada for elemental concentrations indicated that, in general, foliose C. texana present similar or higher concentrations than those presented by fruticose Usnea. (author)

  12. Optical selection of trace elements for discriminant analysis

    International Nuclear Information System (INIS)

    Rasmussen, S.E.; Erasmus, C.S.; Watterson, J.I.W.; Sellschop, J.P.F.

    This report describes different methods of element selection; a combination of stepwise multivariate analysis of variance for primary element selection, and principle component analysis regression for the element interrelationship analysis. These offer a satisfactory solution to the problem of element selection

  13. Probabilistic finite elements for transient analysis in nonlinear continua

    Science.gov (United States)

    Liu, W. K.; Belytschko, T.; Mani, A.

    1985-01-01

    The probabilistic finite element method (PFEM), which is a combination of finite element methods and second-moment analysis, is formulated for linear and nonlinear continua with inhomogeneous random fields. Analogous to the discretization of the displacement field in finite element methods, the random field is also discretized. The formulation is simplified by transforming the correlated variables to a set of uncorrelated variables through an eigenvalue orthogonalization. Furthermore, it is shown that a reduced set of the uncorrelated variables is sufficient for the second-moment analysis. Based on the linear formulation of the PFEM, the method is then extended to transient analysis in nonlinear continua. The accuracy and efficiency of the method is demonstrated by application to a one-dimensional, elastic/plastic wave propagation problem. The moments calculated compare favorably with those obtained by Monte Carlo simulation. Also, the procedure is amenable to implementation in deterministic FEM based computer programs.

  14. Elements of healthy death: a thematic analysis.

    Science.gov (United States)

    Estebsari, Fatemeh; Taghdisi, Mohammad Hossein; Mostafaei, Davood; Rahimi, Zahra

    2017-01-01

    Background: Death is a natural and frightening phenomenon, which is inevitable. Previous studies on death, which presented a negative and tedious image of this process, are now being revised and directed towards acceptable death and good death. One of the proposed terms about death and dying is "healthy death", which encourages dealing with death positively and leading a lively and happy life until the last moment. This study aimed to explain the views of Iranians about the elements of healthy death. Methods: This qualitative study was conducted for 12 months in two general hospitals in Tehran (capital of Iran), using the thematic analysis method. After conducting 23 in-depth interviews with 21 participants, transcription of content, and data immersion and analysis, themes, as the smallest meaningful units were extracted, encoded and classified. Results: One main category of healthy death with 10 subthemes, including dying at the right time, dying without hassle, dying without cost, dying without dependency and control, peaceful death, not having difficulty at dying, not dying alone and dying at home, inspired death, preplanned death, and presence of a clergyman or a priest, were extracted as the elements of healthy death from the perspective of the participants in this study. Conclusion: The study findings well explained the elements of healthy death. Paying attention to the conditions and factors causing healthy death by professionals and providing and facilitating quality services for patients in the end stage of life make it possible for patients to experience a healthy death.

  15. Integral finite element analysis of turntable bearing with flexible rings

    Science.gov (United States)

    Deng, Biao; Liu, Yunfei; Guo, Yuan; Tang, Shengjin; Su, Wenbin; Lei, Zhufeng; Wang, Pengcheng

    2018-03-01

    This paper suggests a method to calculate the internal load distribution and contact stress of the thrust angular contact ball turntable bearing by FEA. The influence of the stiffness of the bearing structure and the plastic deformation of contact area on the internal load distribution and contact stress of the bearing is considered. In this method, the load-deformation relationship of the rolling elements is determined by the finite element contact analysis of a single rolling element and the raceway. Based on this, the nonlinear contact between the rolling elements and the inner and outer ring raceways is same as a nonlinear compression spring and bearing integral finite element analysis model including support structure was established. The effects of structural deformation and plastic deformation on the built-in stress distribution of slewing bearing are investigated on basis of comparing the consequences of load distribution, inner and outer ring stress, contact stress and other finite element analysis results with the traditional bearing theory, which has guiding function for improving the design of slewing bearing.

  16. Dissipation element analysis of turbulent scalar fields

    International Nuclear Information System (INIS)

    Wang Lipo; Peters, Norbert

    2008-01-01

    Dissipation element analysis is a new approach for studying turbulent scalar fields. Gradient trajectories starting from each material point in a scalar field Φ'(x-vector,t) in ascending directions will inevitably reach a maximal and a minimal point. The ensemble of material points sharing the same pair ending points is named a dissipation element. Dissipation elements can be parameterized by the length scale l and the scalar difference Δφ ', which are defined as the straight line connecting the two extremal points and the scalar difference at these points, respectively. The decomposition of a turbulent field into dissipation elements is space-filling. This allows us to reconstruct certain statistical quantities of fine scale turbulence which cannot be obtained otherwise. The marginal probability density function (PDF) of the length scale distribution based on a Poisson random cutting-reconnection process shows satisfactory agreement with the direct numerical simulation (DNS) results. In order to obtain the further information that is needed for the modeling of scalar mixing in turbulence, such as the marginal PDF of the length of elements and all conditional moments as well as their scaling exponents, there is a need to model the joint PDF of l and Δφ ' as well. A compensation-defect model is put forward in this work to show the dependence of Δφ ' on l. The agreement between the model prediction and DNS results is satisfactory, which may provide another explanation of the Kolmogorov scaling and help to improve turbulent mixing models. Furthermore, intermittency and cliff structure can also be related to and explained from the joint PDF.

  17. Reliability analysis of dispersion nuclear fuel elements

    Science.gov (United States)

    Ding, Shurong; Jiang, Xin; Huo, Yongzhong; Li, Lin an

    2008-03-01

    Taking a dispersion fuel element as a special particle composite, the representative volume element is chosen to act as the research object. The fuel swelling is simulated through temperature increase. The large strain elastoplastic analysis is carried out for the mechanical behaviors using FEM. The results indicate that the fission swelling is simulated successfully; the thickness increments grow linearly with burnup; with increasing of burnup: (1) the first principal stresses at fuel particles change from tensile ones to compression ones, (2) the maximum Mises stresses at the particles transfer from the centers of fuel particles to the location close to the interfaces between the matrix and the particles, their values increase with burnup; the maximum Mises stresses at the matrix exist in the middle location between the two particles near the mid-plane along the length (or width) direction, and the maximum plastic strains are also at the above region.

  18. Reliability analysis of dispersion nuclear fuel elements

    Energy Technology Data Exchange (ETDEWEB)

    Ding Shurong [Department of Mechanics and Engineering Science, Fudan University, Shanghai 200433 (China)], E-mail: dsr1971@163.com; Jiang Xin [Department of Mechanics and Engineering Science, Fudan University, Shanghai 200433 (China); Huo Yongzhong [Department of Mechanics and Engineering Science, Fudan University, Shanghai 200433 (China)], E-mail: yzhuo@fudan.edu.cn; Li Linan [Department of Mechanics, Tianjin University, Tianjin 300072 (China)

    2008-03-15

    Taking a dispersion fuel element as a special particle composite, the representative volume element is chosen to act as the research object. The fuel swelling is simulated through temperature increase. The large strain elastoplastic analysis is carried out for the mechanical behaviors using FEM. The results indicate that the fission swelling is simulated successfully; the thickness increments grow linearly with burnup; with increasing of burnup: (1) the first principal stresses at fuel particles change from tensile ones to compression ones, (2) the maximum Mises stresses at the particles transfer from the centers of fuel particles to the location close to the interfaces between the matrix and the particles, their values increase with burnup; the maximum Mises stresses at the matrix exist in the middle location between the two particles near the mid-plane along the length (or width) direction, and the maximum plastic strains are also at the above region.

  19. A Study on the Effect of Cohesive Laws on Finite Element Analysis of Crack Propagation Using Cohesive Elements

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyeongseok; Baek, Hyungchan; Kim, Hyungyu [Seoul Nat' l Univ. of Sci. and Tech., Seoul (Korea, Republic of)

    2014-04-15

    In this paper, the effect of cohesive laws on the finite element analysis of crack propagation using cohesive elements is investigated through three-point bending and double cantilever beam problems. The cohesive elements are implemented into ABAQUS/Standard user subroutines(UEL), and the shape of cohesive law is varied by changing parameters in polynomial functions of cohesive traction-separation relations. In particular, crack propagation behaviors are studied by comparing load-displacement curves of the analysis models which have different shapes of cohesive laws with the same values of fracture energy and cohesive strength. Furthermore, the influence of the element size on crack propagation is discussed in this study.

  20. Finite element analysis of an inflatable torus considering air mass structural element

    Science.gov (United States)

    Gajbhiye, S. C.; Upadhyay, S. H.; Harsha, S. P.

    2014-01-01

    Inflatable structures, also known as gossamer structures, are at high boom in the current space technology due to their low mass and compact size comparing to the traditional spacecraft designing. Internal pressure becomes the major source of strength and rigidity, essentially stiffen the structure. However, inflatable space based membrane structure are at high risk to the vibration disturbance due to their low structural stiffness and material damping. Hence, the vibration modes of the structure should be known to a high degree of accuracy in order to provide better control authority. In the past, most of the studies conducted on the vibration analysis of gossamer structures used inaccurate or approximate theories in modeling the internal pressure. The toroidal shaped structure is one of the important key element in space application, helps to support the reflector in space application. This paper discusses the finite-element analysis of an inflated torus. The eigen-frequencies are obtained via three-dimensional small-strain elasticity theory, based on extremum energy principle. The two finite-element model (model-1 and model-2) have cases have been generated using a commercial finite-element package. The structure model-1 with shell element and model-2 with the combination of the mass of enclosed fluid (air) added to the shell elements have been taken for the study. The model-1 is computed with present analytical approach to understand the convergence rate and the accuracy. The convergence study is made available for the symmetric modes and anti-symmetric modes about the centroidal-axis plane, meeting the eigen-frequencies of an inflatable torus with the circular cross section. The structural model-2 is introduced with air mass element and analyzed its eigen-frequency with different aspect ratio and mode shape response using in-plane and out-plane loading condition are studied.

  1. Failure analysis for WWER-fuel elements

    International Nuclear Information System (INIS)

    Boehmert, J.; Huettig, W.

    1986-10-01

    If the fuel defect rate proves significantly high, failure analysis has to be performed in order to trace down the defect causes, to implement corrective actions, and to take measures of failure prevention. Such analyses are work-consuming and very skill-demanding technical tasks, which require examination methods and devices excellently developed and a rich stock of experience in evaluation of features of damage. For that this work specifies the procedure of failure analyses in detail. Moreover prerequisites and experimental equipment for the investigation of WWER-type fuel elements are described. (author)

  2. Finite element analysis of permanent magnet motors

    International Nuclear Information System (INIS)

    Boglietti, A.; Chiampi, M.; Tartaglia, M.; Chiarabaglio, D.

    1989-01-01

    The analysis of permanent magnet D.C. brushless motors, supplied by current control inverters, is developed employing a finite element package tailored for such devices. The study is devoted to predicting the performance of a set of four poles machines, under different operating conditions (no-load, rated load). The over-load conditions are also considered including the saturation effect. Moreover the influence of such design parameters, as the tooth shape and the number of magnet segments, is investigated. Computed results are found in satisfactory agreement with experimental ones

  3. Nuclear power ecology: comparative analysis

    International Nuclear Information System (INIS)

    Trofimenko, A.P.; Lips'ka, A.Yi.; Pisanko, Zh.Yi.

    2005-01-01

    Ecological effects of different energy sources are compared. Main actions for further nuclear power development - safety increase and waste management, are noted. Reasons of restrained public position to nuclear power and role of social and political factors in it are analyzed. An attempt is undertaken to separate real difficulties of nuclear power from imaginary ones that appear in some mass media. International actions of environment protection are noted. Risk factors at different energy source using are compared. The results of analysis indicate that ecological influence and risk for nuclear power are of minimum

  4. BANK RATING. A COMPARATIVE ANALYSIS

    Directory of Open Access Journals (Sweden)

    Batrancea Ioan

    2015-07-01

    Full Text Available Banks in Romania offers its customers a wide range of products but which involves both risk taking. Therefore researchers seek to build rating models to help managers of banks to risk of non-recovery of loans and interest. In the following we highlight rating Raiffeisen Bank, BCR-ERSTE Bank and Transilvania Bank, based on the models CAAMPL and Stickney making a comparative analysis of the two rating models.

  5. Analysis of Piezoelectric Solids using Finite Element Method

    Science.gov (United States)

    Aslam, Mohammed; Nagarajan, Praveen; Remanan, Mini

    2018-03-01

    Piezoelectric materials are extensively used in smart structures as sensors and actuators. In this paper, static analysis of three piezoelectric solids is done using general-purpose finite element software, Abaqus. The simulation results from Abaqus are compared with the results obtained using numerical methods like Boundary Element Method (BEM) and meshless point collocation method (PCM). The BEM and PCM are cumbersome for complex shape and complicated boundary conditions. This paper shows that the software Abaqus can be used to solve the governing equations of piezoelectric solids in a much simpler and faster way than the BEM and PCM.

  6. Trace element analysis: a diagnostic tool

    International Nuclear Information System (INIS)

    Qureshi, I.H.; Cheema, M.N.

    1976-09-01

    The human mody continuously assimilates a variety of elements from the environment, and the concentration of these elements in the blood is regulated by means of various homeostatic mechanisms. Some of the elements, though present in very small amounts, have highly specialized functions in initiating many biochemical reactions. These elements, known as essential trace elements, are closely related to human diseases since their deficiency or excess induces physiological changes. Many diseases such as hypertension, atherosclerosis, diabetes, etc., are related to an imbalance in trace element. The measurement of trace elements in body fluids and tissues can, therefore, be effectively employed for diagnostic tests

  7. Simultaneous multi-element analysis of some edible pulses using neutron activation analysis

    International Nuclear Information System (INIS)

    El-Sweify, F.H.; Metwally, E.; Abdel-Khalik, H.

    2007-01-01

    This paper comprises the application of instrumental neutron activation analysis (INAA) for multi-element determination in some edible pulse samples. These edible pulses are usually daily used in the Egyptian kitchen. These were: anise, cumin, coriander, caraway, black cumin, white kidney bean, lupine, lentil, chickpea, broad bean, peanut, almond, and fenugreek. The pulses have been analyzed as dehulled pulses, in the case of legume and oil pulses with simultaneous analysis of their respective skins. The determined elements were: Ce, Co, Cr, Cs, Eu, Fe, Hf, Rb, Sb, Sc, Sr, Th and Zn. The element content in the dehulled pulses and their respective skins has been compared. Some elements were major or minor elements where others were trace elements. Standard reference materials were used to assure quality control, accuracy and precision of the technique. (author)

  8. Trace elements in coloured opals using neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    McOrist, G.D.; Smallwood, A. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1996-12-31

    Neutron activation analysis (NAA) is a technique particularly suited to analysing opals since it is non-destructive and the silica matrix of opals is not prone to significant activation. It was used to determine the concentration of trace elements in 50 samples of orange, yellow, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were then evaluated to determine if a relationship existed between trace element content and opal colour. The mean concentration of most of the elements found in orange, yellow and colourless opals were similar with few exceptions. This indicated that, for these samples, colour is not related to the trace elements present. However, the trace element profile of the green, pink and blue opals was found to be significantly different with each colour having a much higher concentration of certain trace elements when compared with all other opals analysed. 7 refs.

  9. Trace elements in coloured opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Smallwood, A.

    1996-01-01

    Neutron activation analysis (NAA) is a technique particularly suited to analysing opals since it is non-destructive and the silica matrix of opals is not prone to significant activation. It was used to determine the concentration of trace elements in 50 samples of orange, yellow, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were then evaluated to determine if a relationship existed between trace element content and opal colour. The mean concentration of most of the elements found in orange, yellow and colourless opals were similar with few exceptions. This indicated that, for these samples, colour is not related to the trace elements present. However, the trace element profile of the green, pink and blue opals was found to be significantly different with each colour having a much higher concentration of certain trace elements when compared with all other opals analysed. 7 refs

  10. Trace elements in coloured opals using neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    McOrist, G D; Smallwood, A [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1997-12-31

    Neutron activation analysis (NAA) is a technique particularly suited to analysing opals since it is non-destructive and the silica matrix of opals is not prone to significant activation. It was used to determine the concentration of trace elements in 50 samples of orange, yellow, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were then evaluated to determine if a relationship existed between trace element content and opal colour. The mean concentration of most of the elements found in orange, yellow and colourless opals were similar with few exceptions. This indicated that, for these samples, colour is not related to the trace elements present. However, the trace element profile of the green, pink and blue opals was found to be significantly different with each colour having a much higher concentration of certain trace elements when compared with all other opals analysed. 7 refs.

  11. Forensic Comparison of Soil Samples Using Nondestructive Elemental Analysis.

    Science.gov (United States)

    Uitdehaag, Stefan; Wiarda, Wim; Donders, Timme; Kuiper, Irene

    2017-07-01

    Soil can play an important role in forensic cases in linking suspects or objects to a crime scene by comparing samples from the crime scene with samples derived from items. This study uses an adapted ED-XRF analysis (sieving instead of grinding to prevent destruction of microfossils) to produce elemental composition data of 20 elements. Different data processing techniques and statistical distances were evaluated using data from 50 samples and the log-LR cost (C llr ). The best performing combination, Canberra distance, relative data, and square root values, is used to construct a discriminative model. Examples of the spatial resolution of the method in crime scenes are shown for three locations, and sampling strategy is discussed. Twelve test cases were analyzed, and results showed that the method is applicable. The study shows how the combination of an analysis technique, a database, and a discriminative model can be used to compare multiple soil samples quickly. © 2016 American Academy of Forensic Sciences.

  12. Finite element analysis of multilayer coextrusion.

    Energy Technology Data Exchange (ETDEWEB)

    Hopkins, Matthew Morgan; Schunk, Peter Randall; Baer, Thomas A. (Proctor & Gamble Company, West Chester, OH); Mrozek, Randy A. (Army Research Laboratory, Adelphi, MD); Lenhart, Joseph Ludlow (Army Research Laboratory, Adelphi, MD); Rao, Rekha Ranjana; Collins, Robert (Oak Ridge National Laboratory); Mondy, Lisa Ann

    2011-09-01

    Multilayer coextrusion has become a popular commercial process for producing complex polymeric products from soda bottles to reflective coatings. A numerical model of a multilayer coextrusion process is developed based on a finite element discretization and two different free-surface methods, an arbitrary-Lagrangian-Eulerian (ALE) moving mesh implementation and an Eulerian level set method, to understand the moving boundary problem associated with the polymer-polymer interface. The goal of this work is to have a numerical capability suitable for optimizing and troubleshooting the coextrusion process, circumventing flow instabilities such as ribbing and barring, and reducing variability in layer thickness. Though these instabilities can be both viscous and elastic in nature, for this work a generalized Newtonian description of the fluid is used. Models of varying degrees of complexity are investigated including stability analysis and direct three-dimensional finite element free surface approaches. The results of this work show how critical modeling can be to reduce build test cycles, improve material choices, and guide mold design.

  13. Trace element analysis of common salt using neutron activation analysis

    International Nuclear Information System (INIS)

    Usman, K.

    1993-01-01

    Instrumental Fast Neutron Activation Analysis (IFNAA) technique has been used in the qualitative and quantitative determination of the impurity elements in common salt. Samples of the different types of common salt processed in Nigeria and some of those imported into the country were used. The type A711 KAMAN neutron generator and a high-purity Germanium (HpGe) gamma spectrometer available at the Centre for Energy Research and Training, Ahmadu Bello University, Zaria has been used. The ORTEC ADCAM 100 Emulation Software (Maestro) was used in the qualitative measurement of the detected elements. The G.R.G Activation Analysis System by G. R. Gilmore, 1987, was used in the quantitative determination of the elements detected by relative method. Aluminium and arsenic were detected and measured

  14. Trace elemental analysis of the aerosol particulates in northern Punjab

    International Nuclear Information System (INIS)

    Iqbal, M.Z.

    2002-01-01

    Trace elemental analysis of the aerosol particulates was studied in the atmosphere of Lahore, Faisalabad, Islamabad, Sheikhupura, Wah Cantt. And Khanispur. The amount of the aerosol particulates in the above mentioned areas was compared to the U.S. EPA maximum permissible limits. Scavenging mechanism of the aerosol particulates through precipitation was studied in the atmosphere of Lahore and Sheikhupura by using HPLC and ICP-AES techniques. The site distribution and morphological structure of the aerosol particulates was studied by using Scanning Electron Microscope model JSM-35CF. Trace elemental composition of the aerosol particulates in the atmosphere of the selected areas of Pakistan was carried out by using NAA. The elements thus studied were Ce, Yb, Se, Cr, Hf, Cs, Sc, Fe, Co, Eu, Sb, Mo, Ba, Zn, Hg, Br, Na, Gd, Sm, Nd and In while Pb and Cd were estimated by using ASS technique. (author)

  15. Analysis and Design of Rolling Stock Elements

    Directory of Open Access Journals (Sweden)

    M. V. Chugunov

    2014-01-01

    Full Text Available The work solves the problem of equal-strength design of the rolling stock elements in option of discrete equal-strength. For this purpose, has been developed the software built in SolidWorks and SolidWorks Simulation as an AddIn-application using necessary basic functionality and extending it in the specified part on the basis of API SolidWorks and COM technology.The SolidWorks software is used to develop a 3D-model for general force frame of the wagon as an assembly. As this assembly is quite complicated and includes many elements both standard, and non-standard type, 3D - specification is developed by 3Dvia Composer software, which is included in the article in the form of the gif-animation and via-roller. This means is very useful for the evident analysis of topology and geometrical properties of a design as a whole, facilitates a procedure of adequate formation of the FE model providing accuracy and profitability of computing. From the point of view of profitability and opportunities of definition of concentrators of stresses with a sufficient accuracy for practice the combined model including volume and shell FEM is optimum.In the work the analysis results of stress-strain state of a design are given in two options of static loading in the form of stress diagrams, the main areas of stress concentration are revealed.Results of equal-strength design in the form of thickness distribution on thin-walled elements of a design, considered within FEM as shells, are received. It is shown that the developed software doesn't allow optimum design results, however it is economically viable, simple in use and can be applied to the solution of problems of rational design in design practice.SolidWorks, as well as the majority of similar CADs, possess an open architecture and allow users to apply its functionality. This work continues a series of publications of the author of this paper and other authors concerning the API-based CAD/CAE adaptation and

  16. Comparing geological and statistical approaches for element selection in sediment tracing research

    Science.gov (United States)

    Laceby, J. Patrick; McMahon, Joe; Evrard, Olivier; Olley, Jon

    2015-04-01

    Elevated suspended sediment loads reduce reservoir capacity and significantly increase the cost of operating water treatment infrastructure, making the management of sediment supply to reservoirs of increasingly importance. Sediment fingerprinting techniques can be used to determine the relative contributions of different sources of sediment accumulating in reservoirs. The objective of this research is to compare geological and statistical approaches to element selection for sediment fingerprinting modelling. Time-integrated samplers (n=45) were used to obtain source samples from four major subcatchments flowing into the Baroon Pocket Dam in South East Queensland, Australia. The geochemistry of potential sources were compared to the geochemistry of sediment cores (n=12) sampled in the reservoir. The geochemical approach selected elements for modelling that provided expected, observed and statistical discrimination between sediment sources. Two statistical approaches selected elements for modelling with the Kruskal-Wallis H-test and Discriminatory Function Analysis (DFA). In particular, two different significance levels (0.05 & 0.35) for the DFA were included to investigate the importance of element selection on modelling results. A distribution model determined the relative contributions of different sources to sediment sampled in the Baroon Pocket Dam. Elemental discrimination was expected between one subcatchment (Obi Obi Creek) and the remaining subcatchments (Lexys, Falls and Bridge Creek). Six major elements were expected to provide discrimination. Of these six, only Fe2O3 and SiO2 provided expected, observed and statistical discrimination. Modelling results with this geological approach indicated 36% (+/- 9%) of sediment sampled in the reservoir cores were from mafic-derived sources and 64% (+/- 9%) were from felsic-derived sources. The geological and the first statistical approach (DFA0.05) differed by only 1% (σ 5%) for 5 out of 6 model groupings with only

  17. Qualitative PIXE analysis of mineral elements in some dental composites

    International Nuclear Information System (INIS)

    Preoteasa, E.A.; Iordan, Andreea; Harangus, Livia; Ciortea, C.; Gugiu, M.; Moldovan, Maria

    2002-01-01

    Dental composites, made by particles of glass, ceramics and quartz embedded in an organic polymer, develop at a high rate. However, commercial composites are expensive and recently the 'Restacril' biomaterials company became prepared to offer a low-cost alternative. The durability of dental fillings depends not only on biomaterial's gross chemical composition, but also on impurities. These may influence the chemical, mechanical and surface properties of the inorganic particles and modify the composites' clinical behavior. Thus elemental analysis is necessary to improve the biomaterials' quality. Nuclear and atomic methods allow sensitive multielement detection, and we previously analyzed some commercial composites by particle-induced X-ray emission (PIXE). Here we applied PIXE in the qualitative analysis of six new Romanian biomaterials, aiming to compare their nominal and detected composition and paying attention to the impurities. The PIXE measurements were performed with 3 MeV protons at the 8.5 MV NIPNE-HH tandem accelerator, using a hyper pure Ge detector, normal to the beam and connected to a multichannel analyzer and to a computer. Solid samples of composites with a flat surface were fixed at 45 angle, absorber foil of Al 30 mm thick was used, and integration of beam current was done. In all composites PIXE detected mineral elements with Z > 19 down to trace levels. All major nominal elements with Z > 20 - Ca, Sr, Zr, Ba, and Yb - were detected by PIXE. In addition, many minor and trace elements absent from the nominal formulations were seen, including K, Ti, Mn, Fe, Ni, Cu, Zn, Ga, Ag, Cd, Hf, and As/Pb. Such impurities may come from rough materials and preparative technologies. The impurities in Romanian composites are comparable to those in some commercial biomaterials but higher than in other ones. Thus PIXE analysis of mineral elements in Romanian composites, even qualitative, appears useful for quality control and improvement. (authors)

  18. Prediction and phylogenetic analysis of mammalian short interspersed elements (SINEs).

    Science.gov (United States)

    Rogozin, I B; Mayorov, V I; Lavrentieva, M V; Milanesi, L; Adkison, L R

    2000-09-01

    The presence of repetitive elements can create serious problems for sequence analysis, especially in the case of homology searches in nucleotide sequence databases. Repetitive elements should be treated carefully by using special programs and databases. In this paper, various aspects of SINE (short interspersed repetitive element) identification, analysis and evolution are discussed.

  19. Nonlinear Finite Element Analysis of Reinforced Concrete Shells

    Directory of Open Access Journals (Sweden)

    Mustafa K. Ahmed

    2013-05-01

    Full Text Available This investigation is to develop a numerical model suitable for nonlinear analysis of reinforced concrete shells. A nine-node Lagrangian element Figure (1 with enhanced shear interpolation will be used in this study. Table (1 describes shape functions and their derivatives of this element.An assumed transverse shear strain is used in the formulation of this element to overcome shear locking. Degenerated quadratic thick plate elements employing a layered discrelization through the thickness will be adopted. Different numbers of layers for different thickness can be used per element. A number of layers between (6 and 10 have proved to be appropriate to represent the nonlinear material behavior in structures. In this research 8 layers will be adequate. Material nonlinearities due to cracking of concrete, plastic flow or crushing of concrete in compression and yield condition of reinforcing steel are considered. The maximum tensile strength is used as a criterion for crack initiation. Attention is given to the tension stiffening phenomenon and the degrading effect of cracking on the compressive and shear strength of concrete. Perfect bond between concrete and steel is assumed. Attention is given also to geometric nonlinearities. An example have been chosen in order to demonstrate the suitability of the models by comparing the predicted behaviour with the experimental results for shell exhibiting various modes of failure.

  20. lsnjbhakta@gmail.com A Comparative SEM-EDS Elemental

    African Journals Online (AJOL)

    Michael Horsfall

    effect on food production in terrestrial and aquatic compartment in ... Processing and SEM-EDS analysis of mud: In the laboratory, the ... and for SEM image observation was 15 kV, applying .... by weathering in the Omi acid clay deposit, Japan.

  1. Finite element analysis of plastic recycling machine designed for ...

    African Journals Online (AJOL)

    ... design was evaluated using finite element analysis (FEA) tool in Solid Works Computer ... Also, a minimum factor of safety value of 5.3 was obtained for shredder shaft ... Machine; Design; Recycling; Sustainability; Finite Element; Simulation ...

  2. Stability analysis of artificial synthetic overweight elements

    International Nuclear Information System (INIS)

    Zhou Jian

    1990-01-01

    Stability of artificial synthetic overweight elements has been analysed theoretically using a diagram of nuclear stability. It is indicated that overweight nucleus can be synthesized only when a certain amount of neutrons participate simultaneously in the synthesis. The maximum number of protons in overweight elements is 1002. The proton number of 'extreme overweight' elements of which the neutron star is possibly composed is in the range from 326 to 1002. It is expected that the mass number of the stable overweight elements with proton number 114 is in the range from 299 to 315

  3. XRF analysis of portland cement for major and trace elements

    International Nuclear Information System (INIS)

    Abdunnabi, A. R.

    2012-12-01

    Libyan portland cement produced in several factories around the country, in Lip tis, Zoltan, Souq-Elkamis, Dernah and El-Fatach, were analyzed for quantitative major and trace elements and mineral content, which were compered with those imported from Spain, Romania, Cyprus, and Egypt. X-ray fluorescence spectro X lab 2000 spectrometer equipped with Rh-and X-ray tube was used for the analysis of various samples. The detector Si(Li) with a resolution of 148 eV at Mn K-a=5.9 keV facilitates the determination of a wide range of elements from sodium to uranium, with a detection limit at sub levels. Cement samples in the powder form were analyzed using the pellet-technique. The pellets were prepared by mixing 4g of the cement powder with 0.9 g of binder (HWC) and pressed at high pressure. A ful analysis including, background counting, matrix correction and all relevant corrections were achieved automatically by XLAB 2000 software package. For major and trace elements X RF results were higher for most of the elements than those analyzed with atomic absorption spectrometry. The mineral content showed that Libyan cement is comparable to the imported ones, also the Libyan cement meets the requirements of the international specifications of the portland cement. (Author)

  4. Electromagnetic analysis of control element drive mechanism for KSNP

    International Nuclear Information System (INIS)

    Kim, H. M.; Kim, I. G.; Kim, I. Y.

    2002-01-01

    The magnetic jack type Control Element Drive Mechanism (CEDM) for Korean Standard Nuclear Power Plant (KSNP) is an electromechanical device which provides controlled linear motion to the Control Element Assembly (CEA) through the Extension Shaft Assembly (ESA) in response to operational signals received from the Control Element Drive Mechanism Control System (CEDMCS). The CEDM is operated by applying localized magnetic flux fields to movable latch and lift magnets, which are in the coolant pressure boundary. The CEDM design had been developed through electromechanical testing of the system including the magnetic force lifting the ESA. But it will be inefficient if parametric studies should be performed to improve the CEDM by test due to the consumption of high cost and long duration. So it becomes necessary to develop a computational model to simulate the electromagnetic characteristics of the CEDM to improve the CEDM design efficiently. In this paper, the electromagnetic analysis using a 2D finite element model has been carried out to simulate magnetic force of the lift magnet of the CEDM, to provide effective evaluation between leakage flux and lift force and to compare with test results. Analysis results show the lift force satisfied the test results and design requirement and the lift force depend on the shape of the components, leakage flux and B-H curve

  5. Chromatographic Techniques for Rare Earth Elements Analysis

    Science.gov (United States)

    Chen, Beibei; He, Man; Zhang, Huashan; Jiang, Zucheng; Hu, Bin

    2017-04-01

    The present capability of rare earth element (REE) analysis has been achieved by the development of two instrumental techniques. The efficiency of spectroscopic methods was extraordinarily improved for the detection and determination of REE traces in various materials. On the other hand, the determination of REEs very often depends on the preconcentration and separation of REEs, and chromatographic techniques are very powerful tools for the separation of REEs. By coupling with sensitive detectors, many ambitious analytical tasks can be fulfilled. Liquid chromatography is the most widely used technique. Different combinations of stationary phases and mobile phases could be used in ion exchange chromatography, ion chromatography, ion-pair reverse-phase chromatography and some other techniques. The application of gas chromatography is limited because only volatile compounds of REEs can be separated. Thin-layer and paper chromatography are techniques that cannot be directly coupled with suitable detectors, which limit their applications. For special demands, separations can be performed by capillary electrophoresis, which has very high separation efficiency.

  6. Trace element analysis of soy sauce

    International Nuclear Information System (INIS)

    Tomita, Michio; Haruyama, Yoichi; Saito, Manabu

    1994-01-01

    Trace elements in soy sauce have been measured by means of in-air PIXE. Six kinds of trace elements were detected, such as Mu, Fe, Ni, Zn, Cu and Br. Concentrations of Mn, Fe, Zn and Br which were observed in all samples, have been determined. Each analyzed sample contained considerable amount of bromine about 160 ppm. (author)

  7. Macro elemental analysis of food samples by nuclear analytical technique

    Science.gov (United States)

    Syahfitri, W. Y. N.; Kurniawati, S.; Adventini, N.; Damastuti, E.; Lestiani, D. D.

    2017-06-01

    Energy-dispersive X-ray fluorescence (EDXRF) spectrometry is a non-destructive, rapid, multi elemental, accurate, and environment friendly analysis compared with other detection methods. Thus, EDXRF spectrometry is applicable for food inspection. The macro elements calcium and potassium constitute important nutrients required by the human body for optimal physiological functions. Therefore, the determination of Ca and K content in various foods needs to be done. The aim of this work is to demonstrate the applicability of EDXRF for food analysis. The analytical performance of non-destructive EDXRF was compared with other analytical techniques; neutron activation analysis and atomic absorption spectrometry. Comparison of methods performed as cross checking results of the analysis and to overcome the limitations of the three methods. Analysis results showed that Ca found in food using EDXRF and AAS were not significantly different with p-value 0.9687, whereas p-value of K between EDXRF and NAA is 0.6575. The correlation between those results was also examined. The Pearson correlations for Ca and K were 0.9871 and 0.9558, respectively. Method validation using SRM NIST 1548a Typical Diet was also applied. The results showed good agreement between methods; therefore EDXRF method can be used as an alternative method for the determination of Ca and K in food samples.

  8. PIXE analysis of caries related trace elements in tooth enamel

    International Nuclear Information System (INIS)

    Annegarn, H.J.; Jodaikin, A.; Cleaton-Jones, P.E.; Sellschop, J.P.F.; Madiba, C.C.P.; Bibby, D.; University of the Witwatersrand, Johannesburg

    1981-01-01

    PIXE analysis has been applied to a set of twenty human teeth to determine trace element concentration in enamel from areas suceptible to dental caries (mesial and distal contact points) and in areas less susceptible to the disease (buccal surface), with the aim of determining the possible roles of trace elements in the carious process. The samples were caries-free anterior incisors extracted for periodontal reasons from subjects 10-30 years of age. Prior to extraction of the sample teeth, a detailed dental history and examination was carried out in each individual. PIXE analysis, using a 3 MeV proton beam of 1 mm diameter, allowed the determination of Ca, Mn, Fe, Cu, Zn, Sr and Pb above detection limits. As demonstrated in this work, the enhanced sensitivity of PIXE analysis over electron microprobe analysis, and capability of localised surface analysis compared with the pooled samples require for neutron activation analysis, makes it a powerful and useful technique in dental analysis. (orig.)

  9. PIXE analysis of caries related trace elements in tooth enamel

    Energy Technology Data Exchange (ETDEWEB)

    Annegarn, H J; Jodaikin, A; Cleaton-Jones, P E; Sellschop, J P.F.; Madiba, C C.P.; Bibby, D [University of the Witwatersrand, Johannesburg (South Africa). Nuclear Physics Research Unit; University of the Witwatersrand, Johannesburg (South Africa). Dental Research Unit)

    1981-03-01

    PIXE analysis has been applied to a set of twenty human teeth to determine trace element concentration in enamel from areas suceptible to dental caries (mesial and distal contact points) and in areas less susceptible to the disease (buccal surface), with the aim of determining the possible roles of trace elements in the carious process. The samples were caries-free anterior incisors extracted for periodontal reasons from subjects 10-30 years of age. Prior to extraction of the sample teeth, a detailed dental history and examination was carried out in each individual. PIXE analysis, using a 3 MeV proton beam of 1 mm diameter, allowed the determination of Ca, Mn, Fe, Cu, Zn, Sr and Pb above detection limits. As demonstrated in this work, the enhanced sensitivity of PIXE analysis over electron microprobe analysis, and capability of localised surface analysis compared with the pooled samples require for neutron activation analysis, makes it a powerful and useful technique in dental analysis.

  10. Comparative genome sequencing of drosophila pseudoobscura: Chromosomal, gene and cis-element evolution

    Energy Technology Data Exchange (ETDEWEB)

    Richards, Stephen; Liu, Yue; Bettencourt, Brian R.; Hradecky, Pavel; Letovsky, Stan; Nielsen, Rasmus; Thornton, Kevin; Todd, Melissa J.; Chen, Rui; Meisel, Richard P.; Couronne, Olivier; Hua, Sujun; Smith, Mark A.; Bussemaker, Harmen J.; van Batenburg, Marinus F.; Howells, Sally L.; Scherer, Steven E.; Sodergren, Erica; Matthews, Beverly B.; Crosby, Madeline A.; Schroeder, Andrew J.; Ortiz-Barrientos, Daniel; Rives, Catherine M.; Metzker, Michael L.; Muzny, Donna M.; Scott, Graham; Steffen, David; Wheeler, David A.; Worley, Kim C.; Havlak, Paul; Durbin, K. James; Egan, Amy; Gill, Rachel; Hume, Jennifer; Morgan, Margaret B.; Miner, George; Hamilton, Cerissa; Huang, Yanmei; Waldron, Lenee; Verduzco, Daniel; Blankenburg, Kerstin P.; Dubchak, Inna; Noor, Mohamed A.F.; Anderson, Wyatt; White, Kevin P.; Clark, Andrew G.; Schaeffer, Stephen W.; Gelbart, William; Weinstock, George M.; Gibbs, Richard A.

    2004-04-01

    The genome sequence of a second fruit fly, D. pseudoobscura, presents an opportunity for comparative analysis of a primary model organism D. melanogaster. The vast majority of Drosophila genes have remained on the same arm, but within each arm gene order has been extensively reshuffled leading to the identification of approximately 1300 syntenic blocks. A repetitive sequence is found in the D. pseudoobscura genome at many junctions between adjacent syntenic blocks. Analysis of this novel repetitive element family suggests that recombination between offset elements may have given rise to many paracentric inversions, thereby contributing to the shuffling of gene order in the D. pseudoobscura lineage. Based on sequence similarity and synteny, 10,516 putative orthologs have been identified as a core gene set conserved over 35 My since divergence. Genes expressed in the testes had higher amino acid sequence divergence than the genome wide average consistent with the rapid evolution of sex-specific proteins. Cis-regulatory sequences are more conserved than control sequences between the species but the difference is slight, suggesting that the evolution of cis-regulatory elements is flexible. Overall, a picture of repeat mediated chromosomal rearrangement, and high co-adaptation of both male genes and cis-regulatory sequences emerges as important themes of genome divergence between these species of Drosophila.

  11. Elemental Analysis and Biological Activities of Chrysophyllum ...

    African Journals Online (AJOL)

    Sapotaceae) Leaves. ... The plant material could be used as a source of important elements required for the body. In suitable form, the plant could be used in the prevention and treatment of dental caries, oxidative damage, obesity and cancer.

  12. Comparative Study of Elemental Nutrients in Organic and Conventional Vegetables Using Laser-Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Bhatt, Chet R; Alfarraj, Bader; Ghany, Charles T; Yueh, Fang Y; Singh, Jagdish P

    2017-04-01

    In this study, the laser-induced breakdown spectroscopy (LIBS) technique was used to identify and compare the presence of major nutrient elements in organic and conventional vegetables. Different parts of cauliflowers and broccolis were used as working samples. Laser-induced breakdown spectra from these samples were acquired at optimum values of laser energy, gate delay, and gate width. Both univariate and multivariate analyses were performed for the comparison of these organic and conventional vegetable flowers. Principal component analysis (PCA) was taken into account for multivariate analysis while for univariate analysis, the intensity of selected atomic lines of different elements and their intensity ratio with some reference lines of organic cauliflower and broccoli samples were compared with those of conventional ones. In addition, different parts of the cauliflower and broccoli were compared in terms of intensity and intensity ratio of elemental lines.

  13. Fingerprint elements scatter analysis on ancient chinese Ru porcelains samples

    International Nuclear Information System (INIS)

    Gao Zhengyao; Wang Jie; Chen Xiande

    1997-01-01

    Altogether 28 samples, mainly including glazes and bodies of ancient Chinese Ru porcelain, were analyzed by NAA technique and the contents of 36 elements were compared. The scatter analysis for nine fingerprint-elements indicates that almost all ancient Chinese Ru porcelain samples had nearly identical and long-term stable source of raw materials although they were fired in different kilns, at varying time and with distinct colors, and moreover, the source of raw materials for modern Ru porcelain seems to approach that for ancient one. The close provenance relation between ancient Jun porcelain and ancient Ru porcelain is also preliminarily verified. The glaze material of Jingdezhen white porcelain is totally different from all other samples. It shows that the former came from a separate source

  14. Finite element analysis theory and application with ANSYS

    CERN Document Server

    Moaveni, Saeed

    2015-01-01

    For courses in Finite Element Analysis, offered in departments of Mechanical or Civil and Environmental Engineering. While many good textbooks cover the theory of finite element modeling, Finite Element Analysis: Theory and Application with ANSYS is the only text available that incorporates ANSYS as an integral part of its content. Moaveni presents the theory of finite element analysis, explores its application as a design/modeling tool, and explains in detail how to use ANSYS intelligently and effectively. Teaching and Learning Experience This program will provide a better teaching and learning experience-for you and your students. It will help: *Present the Theory of Finite Element Analysis: The presentation of theoretical aspects of finite element analysis is carefully designed not to overwhelm students. *Explain How to Use ANSYS Effectively: ANSYS is incorporated as an integral part of the content throughout the book. *Explore How to Use FEA as a Design/Modeling Tool: Open-ended design problems help stude...

  15. Stability of biodegradable metal (Mg-Ca-Zn alloy) screws compared with absorbable polymer and titanium screws for sagittal split ramus osteotomy of the mandible using the finite element analysis model.

    Science.gov (United States)

    Lee, Jee-Ho; Han, Hyung-Seop; Kim, Yu-Chan; Lee, Jin-Yong; Lee, Bu-Kyu

    2017-10-01

    Mg-Ca-Zn alloy has been suggested for the application of fixation materials during maxillofacial surgery. We investigated the stability of Mg-Ca-Zn alloy for clinical application during orthognathic surgery. The finite element model for the fixation of sagittal split ramus osteotomy was constructed. In the bicortical screw fixation of the mandible setback condition, the stress distributions of Mg-Ca-Za alloy, polylactic acid polymer, and titanium were evaluated using the virtual model with occlusal loading of 132 N. The deformations of the three different materials of fixation screw were observed according to masticatory force ranging from 132 to 1,000 N. When comparing the stress distribution placed on cortical bone between the polymer and magnesium alloy groups, the magnesium alloy screws could bear more stress, thereby decreasing the stress, which might be distributed to other biologic components, such as the condyle and cortical ramus of the mandible. Deformations of the screws according to functional load were minimal, and the deformation remained stability of sagittal split ramus osteotomy setback surgery. Copyright © 2017. Published by Elsevier Ltd.

  16. Elemental analysis by IBA and NAA — A critical comparison

    Science.gov (United States)

    Watterson, J. I. W.

    1988-12-01

    In this review neutron activation analysis (NAA) and ion beam analysis (IBA) have been compared in the context of the entire field of analytical science using the discipline of scientometrics, as developed by Braun and Lyon. This perspective on the relative achievements of the two methods is modified by considering and comparing their particular attributes and characteristics, particularly in relation to their differing degree of maturity. This assessment shows that NAA, as the more mature method, is the most widely applied nuclear technique, but the special capabilities of IBA give it the ability to provide information about surface composition and elemental distribution that is unique, while it is still relatively immature and it is not yet possible to define its ultimate role with any confidence.

  17. Analysis of elements present in beers and brewing waters by neutron activation analysis

    International Nuclear Information System (INIS)

    Krausova, Ivana; Kucera, Jan; Dostalek, Pavel; Potesil, Vaclav

    2011-01-01

    Neutron activation analysis (NAA) was used for determination of Si, Na, K, Ca, Sc, V, Cr, Mn, Fe, Co, Zn, Rb, Cs, and La in Czech beers and brewing waters. The Si concentration in beer determined by the reaction 29 Si(n,p) 29 Al with fast neutrons confirmed that beer is an important Si source in human diet. Determination of other trace elements by NAA with the whole spectrum of reactor neutrons aimed at the feasibility of identification of Gambrinus beers brewed in various breweries. The elements Ca and V appeared to be the best candidates for this purpose. The concentrations of elements determined by NAA were also compared with the recommended daily element intake for humans. The accuracy of the method was proved by analysis of reference materials, specifically NIST SRM 2704 Buffalo River Sediment, NIST SRM 1633b Coal Fly Ash, and NIST SRM 1515 Apple Leaves. (author)

  18. Elemental PIXE analysis of oolong tea

    International Nuclear Information System (INIS)

    Watanabe, M.; Ishii, K.; Matsuyama, S.

    2008-01-01

    The contamination of heavy metals in food becomes a serious problem. We analyzed oolong tea from different production areas by PIXE using very simple sample preparation and examined trace elements contained in these samples. From the results of this experiment, we could know oolong tea which analyzed in this experiment contains various minerals such as K, Ca, P, S, Cl, Fe, Mn, Cu and Cr but not toxic element of As which detection limit of PIXE was lower than the standard values given by the food hygiene law in Japan. (author)

  19. Trace element analysis in soy sauce

    International Nuclear Information System (INIS)

    Haruyama, Yoichi; Saito, Manabu; Tomiya, Michio

    1993-01-01

    Trace elements in soy sauce have been measured by means of in-air PIXE. Six kinds of trace elements were detected, such as Mn, Fe, Ni, Zn, Cu and Br. Concentrations of Mn, Fe, Zn and Br which were observed in all samples, have been determined. Each analyzed sample contained considerable amount of Br about 160 ppm. Comparison of Br content of the imported raw materials with those of the domestic ones suggested that the large amount of Br was the residual fumigation chemicals in the imported raw materials. (author)

  20. Thermodynamic analysis of light-actinide elements

    International Nuclear Information System (INIS)

    Brosh, Eli; Makov, Guy; Shneck, Roni Z.

    2005-01-01

    The thermophysical properties of the alpha phases of the light actinide elements Th, U, Np and Pu were analysed. For each of the analysed elements, the Gibbs free-energy was modelled by an explicit function of temperature T and pressure P over the whole relevant T-P range, in a manner compatible with the CALPHAD (Calculation of Alloy Phase Diagrams) method. Several adjustable model-parameters were fitted to available experimental results. The model is based on a new semi-empirical equation of state, which interpolates with Thomas-Fermi type models for the volume and with the Dulong-Petit value for the heat capacity, at extreme pressures

  1. Finite-element analysis of dynamic fracture

    Science.gov (United States)

    Aberson, J. A.; Anderson, J. M.; King, W. W.

    1976-01-01

    Applications of the finite element method to the two dimensional elastodynamics of cracked structures are presented. Stress intensity factors are computed for two problems involving stationary cracks. The first serves as a vehicle for discussing lumped-mass and consistent-mass characterizations of inertia. In the second problem, the behavior of a photoelastic dynamic tear test specimen is determined for the time prior to crack propagation. Some results of a finite element simulation of rapid crack propagation in an infinite body are discussed.

  2. Sociological analysis and comparative education

    Science.gov (United States)

    Woock, Roger R.

    1981-12-01

    It is argued that comparative education is essentially a derivative field of study, in that it borrows theories and methods from academic disciplines. After a brief humanistic phase, in which history and philosophy were central for comparative education, sociology became an important source. In the mid-50's and 60's, sociology in the United States was characterised by Structural Functionalism as a theory, and Social Survey as a dominant methodology. Both were incorporated into the development of comparative education. Increasingly in the 70's, and certainly today, the new developments in sociology are characterised by an attack on Positivism, which is seen as the philosophical position underlying both functionalism and survey methods. New or re-discovered theories with their attendant methodologies included Marxism, Phenomenological Sociology, Critical Theory, and Historical Social Science. The current relationship between comparative education and social science is one of uncertainty, but since social science is seen to be returning to its European roots, the hope is held out for the development of an integrated social theory and method which will provide a much stronger basis for developments in comparative education.

  3. Quantitative analysis of light elements in aerosol samples by PIGE

    International Nuclear Information System (INIS)

    Mateus, R.; Reis, M.A.; Jesus, A.P.; Ribeiro, J.P.

    2006-01-01

    Quantitative PIGE analysis of aerosol samples collected on nuclepore polycarbonate filters was performed by a method that avoids the use of comparative standards. Nuclear cross sections and calibration parameters established before in an extensive work on thick and intermediate samples were employed. For these samples, the excitation functions of nuclear reactions, induced by the incident protons on target's light elements, were used as input for a code that evaluates the gamma-ray yield integrating along the depth of the sample. In the present work we apply the same code to validate the use of an effective energy for thin sample analysis. Results pertaining to boron, fluorine and sodium concentrations are presented. In order to establish a correlation with sodium values, PIXE results related to chlorine are also presented, giving support to the reliability of this PIGE method for thin film analysis

  4. Elemental analysis of samples of rare earths

    International Nuclear Information System (INIS)

    Lopez M, J.; Ramirez T, J.J.; Sandoval J, R.A.; Aspiazu F, J.; Villasenor S, P.; Lugo L, M.F.

    2003-01-01

    Applying the PIXE technique (Particle Induced X-Ray Emission) it was analyzed the purity of the samples that will be used to measure the production section of X rays with Li and B beams. It is not necessary to determine the concentrations of the pollutant elements. (Author)

  5. Elemental analysis of atmospheric aerosols in Gaborone

    African Journals Online (AJOL)

    ELO

    amount more than 90% were copper, lead, nickel and gold. Key words: Atmospheric particles, elements, ... Selebi-Phikwe area, gold and nickel in Francis town and soda ash in Sowa. Gaborone is the capital of ... a stub three times a week with an exposure time of four hours. The exposed stubs were collected and kept ...

  6. Analysis on the Three Elements in Communication

    Institute of Scientific and Technical Information of China (English)

    李霞

    2014-01-01

    In public communication,people may have no troubles to epress themselves grammatically correctly,but sometimes the sentences just sound not pragmatically proper. Through analyzing and comprehending those Elements in English to avoid the misunderstanding and misusing in the communication is significant.

  7. Analysis on 9 Elements in English Pragmatics

    Institute of Scientific and Technical Information of China (English)

    李霞

    2014-01-01

    College Students may have no troubles to compose grammatically correct sentences to express themselves,but sometimes the sentences just seem not pragmatically proper.Through analyzing and comprehending the 9 Elements in English Pragmatics to avoid the misunderstanding and misusing in the communication is significant for English learners,special to one who intends to use English as a communicating medium.

  8. Analysis on the Three Elements in Communication

    Institute of Scientific and Technical Information of China (English)

    李霞

    2014-01-01

    In public communication,people may have no troubles to epress themselves grammatically correctly,but sometimes the sentences just sound not pragmatically proper.Through analyzing and comprehending those Elements in English to avoid the misunderstanding and misusing in the communication is significant.

  9. Comparative Chromatographic Analysis and Pharmacodynamic ...

    African Journals Online (AJOL)

    The laboratory analysis of the Garcinia Kolanuts extracts showed receptors inhibition of Beta adrenergic sites, adenosine, melatonin, opiate, purine, calcium channel L-type and 5HT5A. Conclusion: Garcinia kolanut extract exhibits a combined effects of all the known antiglaucoma drugs used in comparison. NQJHM Vol.

  10. Finite Element Analysis of Pipe T-Joint

    OpenAIRE

    P.M.Gedkar; Dr. D.V. Bhope

    2012-01-01

    This paper reports stress analysis of two pressurized cylindrical intersection using finite element method. The different combinations of dimensions of run pipe and the branch pipe are used to investigate thestresses in pipe at the intersection. In this study the stress analysis is accomplished by finite element package ANSYS.

  11. VIRTUAL EXPERIMENTAL ANALYSIS ON CLEANING ELEMENT OF SUGARCANE HARVESTER

    Institute of Scientific and Technical Information of China (English)

    Ma Fanglan; Li Shangping; He Yulin; Meng Yanmei; Chen Weixu

    2005-01-01

    The laws of influence of different factors have been analyzed in order to enhance the working efficiency and fatigue life of the cleaning element in brush shape of the sugarcane harvester.Based on the principle of orthogonal experiment design, the virtual-orthogonal-experimental analysis for the cleaning element is carried out on the finite element analysis (FEA) software-ANSYS after analyzing the nonlinear structural behavior in the working procedure. The results are analyzed with the overall balancing method, and then the optimal combination is got, which is made up of different levels of different factors. Also the optimal combination of design parameters of the cleaning element received from the virtual experimental analysis is conducted an experiment to confirm that the virtual analysis model and results are right, and the effect of factors on the function of the cleaning element is obtained by more analysis and further optimizing.

  12. Finite element reliability analysis of fatigue life

    International Nuclear Information System (INIS)

    Harkness, H.H.; Belytschko, T.; Liu, W.K.

    1992-01-01

    Fatigue reliability is addressed by the first-order reliability method combined with a finite element method. Two-dimensional finite element models of components with cracks in mode I are considered with crack growth treated by the Paris law. Probability density functions of the variables affecting fatigue are proposed to reflect a setting where nondestructive evaluation is used, and the Rosenblatt transformation is employed to treat non-Gaussian random variables. Comparisons of the first-order reliability results and Monte Carlo simulations suggest that the accuracy of the first-order reliability method is quite good in this setting. Results show that the upper portion of the initial crack length probability density function is crucial to reliability, which suggests that if nondestructive evaluation is used, the probability of detection curve plays a key role in reliability. (orig.)

  13. Finite element analysis of human joints

    Energy Technology Data Exchange (ETDEWEB)

    Bossart, P.L.; Hollerbach, K.

    1996-09-01

    Our work focuses on the development of finite element models (FEMs) that describe the biomechanics of human joints. Finite element modeling is becoming a standard tool in industrial applications. In highly complex problems such as those found in biomechanics research, however, the full potential of FEMs is just beginning to be explored, due to the absence of precise, high resolution medical data and the difficulties encountered in converting these enormous datasets into a form that is usable in FEMs. With increasing computing speed and memory available, it is now feasible to address these challenges. We address the first by acquiring data with a high resolution C-ray CT scanner and the latter by developing semi-automated method for generating the volumetric meshes used in the FEM. Issues related to tomographic reconstruction, volume segmentation, the use of extracted surfaces to generate volumetric hexahedral meshes, and applications of the FEM are described.

  14. Finite element analysis of human joints

    International Nuclear Information System (INIS)

    Bossart, P.L.; Hollerbach, K.

    1996-09-01

    Our work focuses on the development of finite element models (FEMs) that describe the biomechanics of human joints. Finite element modeling is becoming a standard tool in industrial applications. In highly complex problems such as those found in biomechanics research, however, the full potential of FEMs is just beginning to be explored, due to the absence of precise, high resolution medical data and the difficulties encountered in converting these enormous datasets into a form that is usable in FEMs. With increasing computing speed and memory available, it is now feasible to address these challenges. We address the first by acquiring data with a high resolution C-ray CT scanner and the latter by developing semi-automated method for generating the volumetric meshes used in the FEM. Issues related to tomographic reconstruction, volume segmentation, the use of extracted surfaces to generate volumetric hexahedral meshes, and applications of the FEM are described

  15. Elemental analysis: Reduction to SI units; Rueckfuehrung in der Elementanalytik

    Energy Technology Data Exchange (ETDEWEB)

    Rienitz, O.; Jaehrling, R.; Schiel, D. [PTB-Arbeitsgruppe ' ' Anorganische Analytik' ' , Braunschweig (Germany); Matschat, R.; Kipphardt, H. [Bundesanstalt fuer Materialforschung und -pruefung, Berlin (Germany); Gernand, W.; Oeter, D. [MercK KGaA (Germany)

    2005-12-15

    In a joint project, PTB, BAM and Merck KGaA worked on a metrological reduction system for all elements relevant to analysis. The BAM certified primary pure substances with a relative error of U{sub rel} {<=} 0.01% for the mass of the main element. This was achieved by measuring the mass components of all potential impurities, i.e. practically all elements of the periodic system except the main element. These pure substances are the national reference standards of elemental analysis. From them, PTB produces primary elementa solutions and transfer solutions which are passed on as reference standards. The industrial partner constructed the DKD calibration laboratory, which certifies commercial secondary calibration solutions on the basis of the reference standard solutions produced by PTB. With this final product, measurements in elemental analysis can be reduced to the SI units system as a routine procedure. (orig.)

  16. Statistical Energy Analysis (SEA) and Energy Finite Element Analysis (EFEA) Predictions for a Floor-Equipped Composite Cylinder

    Science.gov (United States)

    Grosveld, Ferdinand W.; Schiller, Noah H.; Cabell, Randolph H.

    2011-01-01

    Comet Enflow is a commercially available, high frequency vibroacoustic analysis software founded on Energy Finite Element Analysis (EFEA) and Energy Boundary Element Analysis (EBEA). Energy Finite Element Analysis (EFEA) was validated on a floor-equipped composite cylinder by comparing EFEA vibroacoustic response predictions with Statistical Energy Analysis (SEA) and experimental results. Statistical Energy Analysis (SEA) predictions were made using the commercial software program VA One 2009 from ESI Group. The frequency region of interest for this study covers the one-third octave bands with center frequencies from 100 Hz to 4000 Hz.

  17. A Dual Super-Element Domain Decomposition Approach for Parallel Nonlinear Finite Element Analysis

    Science.gov (United States)

    Jokhio, G. A.; Izzuddin, B. A.

    2015-05-01

    This article presents a new domain decomposition method for nonlinear finite element analysis introducing the concept of dual partition super-elements. The method extends ideas from the displacement frame method and is ideally suited for parallel nonlinear static/dynamic analysis of structural systems. In the new method, domain decomposition is realized by replacing one or more subdomains in a "parent system," each with a placeholder super-element, where the subdomains are processed separately as "child partitions," each wrapped by a dual super-element along the partition boundary. The analysis of the overall system, including the satisfaction of equilibrium and compatibility at all partition boundaries, is realized through direct communication between all pairs of placeholder and dual super-elements. The proposed method has particular advantages for matrix solution methods based on the frontal scheme, and can be readily implemented for existing finite element analysis programs to achieve parallelization on distributed memory systems with minimal intervention, thus overcoming memory bottlenecks typically faced in the analysis of large-scale problems. Several examples are presented in this article which demonstrate the computational benefits of the proposed parallel domain decomposition approach and its applicability to the nonlinear structural analysis of realistic structural systems.

  18. Elemental hair analysis: A review of procedures and applications

    International Nuclear Information System (INIS)

    Pozebon, D.; Scheffler, G.L.; Dressler, V.L.

    2017-01-01

    Although exogenous contamination and unreliable reference values have limited the utility of scalp hair as a biomarker of chemical elements exposure, its use in toxicological, clinical, environmental and forensic investigations is growing and becoming more extensive. Therefore, hair elemental analysis is reviewed in the current manuscript which spans articles published in the last 10 years. It starts with a general discussion of history, morphology and possible techniques for elemental analysis, where inductively coupled plasma-mass spectrometry (ICP-MS) is clearly highlighted since this technique is leading quantitative ultra-trace elemental analysis. Emphasis over sampling, quality assurance, washing procedures and sample decomposition is given with detailed protocols compiled in tables as well as the utility of hair to identify human gender, age, diseases, healthy conditions, nutrition status and contamination sites. Isotope ratio information, chemical speciation analysis and analyte preconcentration are also considered for hair. Finally, the potential of laser ablation ICP-MS (LA-ICP-MS) to provide spatial resolution and time-track the monitoring of elements in hair strands instead of conventional bulk analysis is spotlighted as a real future trend in the field. - Highlights: • Elemental analysis of hair is critically reviewed, with focus on ICP-MS employment. • Standards protocols of hair washing and sample decomposition are compiled. • The usefulness of elemental and/or isotopic analysis of hair is demonstrated. • The potential of LA-ICP-MS for elemental time tracking in hair is highlighted.

  19. Qualitative analysis of the rare earth element by simulation of inductively coupled plasma emission spectra

    International Nuclear Information System (INIS)

    Hashimoto, M.S.; Tobishima, Taeko; Kamitake, Seigo; Yasuda, Kazuo.

    1985-01-01

    The emission lines for qualitative analysis of rare earth elements by a simulation technique of ICP spectra were proposed. The spectra were simulated by employing a Gaussian (or a Lorentzian at high concentrations) profile. The simulated spectra corresponded quite well with the observed ones. The emission lines were selected so that the interference was as small as possible. The present qualitative analysis is based on a pattern recognition method where observed intensity ratios of the emission lines in each element are compared with those of a single analyte element. The qualitative analysis was performed for twelve standard solutions containing a single rare earth element and for eight standard solutions containing an element other than rare earth elements. The selection of the emission lines and the algorithm of the present qualitative analysis were justified. (author)

  20. Neutron-activation analysis of trace elements in thyroids

    International Nuclear Information System (INIS)

    Boulyga, S.F.; Petri, H.; Kanash, N.V.; Malenchenko, A.F.

    1999-01-01

    Neutron activation analysis was used for routine measurement of trace elements in thyroids of inhabitants of Belarus as well as in thyroids of people operated for thyroid cancer. The method chosen allowed the analysis of 28 elements, among them essential and toxic ones, with a good accuracy. The results obtained showed significant differences in the elemental composition of thyroid from the different regions. The changes of elemental composition of thyroids of inhabitants of the Gomel region, where goiter is endemic, seem to be identical to those in the tumor tissue. (author)

  1. Tube Bulge Process : Theoretical Analysis and Finite Element Simulations

    International Nuclear Information System (INIS)

    Velasco, Raphael; Boudeau, Nathalie

    2007-01-01

    This paper is focused on the determination of mechanics characteristics for tubular materials, using tube bulge process. A comparative study is made between two different models: theoretical model and finite element analysis. The theoretical model is completely developed, based first on a geometrical analysis of the tube profile during bulging, which is assumed to strain in arc of circles. Strain and stress analysis complete the theoretical model, which allows to evaluate tube thickness and state of stress, at any point of the free bulge region. Free bulging of a 304L stainless steel is simulated using Ls-Dyna 970. To validate FE simulations approach, a comparison between theoretical and finite elements models is led on several parameters such as: thickness variation at the free bulge region pole with bulge height, tube thickness variation with z axial coordinate, and von Mises stress variation with plastic strain. Finally, the influence of geometrical parameters deviations on flow stress curve is observed using analytical model: deviations of the tube outer diameter, its initial thickness and the bulge height measurement are taken into account to obtain a resulting error on plastic strain and von Mises stress

  2. On constitutive modelling in finite element analysis

    International Nuclear Information System (INIS)

    Bathe, K.J.; Snyder, M.D.; Cleary, M.P.

    1979-01-01

    This compact contains a brief introduction to the problems involved in constitutive modeling as well as an outline of the final paper to be submitted. Attention is focussed on three important areas: (1) the need for using theoretically sound material models and the importance of recognizing the limitations of the models, (2) the problem of developing stable and effective numerical representations of the models, and (3) the necessity for selection of an appropriate finite element mesh that can capture the actual physical response of the complete structure. In the final paper, we will be presenting our recent research results pertaining to each of these problem areas. (orig.)

  3. SEM and elemental analysis of composite resins

    International Nuclear Information System (INIS)

    Hosoda, H.; Yamada, T.; Inokoshi, S.

    1990-01-01

    Twenty-four chemically cured, 21 light-cured anterior, three light-cured anterior/posterior, and 18 light-cured posterior composite resins were examined using scanning electron microscopy, and the elemental composition of their filler particles was analyzed with an energy dispersive electron probe microanalyzer. According to the results obtained, the composite resins were divided into five groups (traditional, microfilled type, submicrofilled type, hybrid type, and semihybrid), with two additional hypothetical categories (microfilled and hybrid). Characteristics of each type were described with clinical indications for selective guidance of respective composite resins for clinical use

  4. Model order reduction techniques with applications in finite element analysis

    CERN Document Server

    Qu, Zu-Qing

    2004-01-01

    Despite the continued rapid advance in computing speed and memory the increase in the complexity of models used by engineers persists in outpacing them. Even where there is access to the latest hardware, simulations are often extremely computationally intensive and time-consuming when full-blown models are under consideration. The need to reduce the computational cost involved when dealing with high-order/many-degree-of-freedom models can be offset by adroit computation. In this light, model-reduction methods have become a major goal of simulation and modeling research. Model reduction can also ameliorate problems in the correlation of widely used finite-element analyses and test analysis models produced by excessive system complexity. Model Order Reduction Techniques explains and compares such methods focusing mainly on recent work in dynamic condensation techniques: - Compares the effectiveness of static, exact, dynamic, SEREP and iterative-dynamic condensation techniques in producing valid reduced-order mo...

  5. Finite element analysis on badminton racket design parameters

    CERN Document Server

    Nasruddin, Fakhrizal Azmy; Syahrom, Ardiyansyah; Abdul Kadir, Mohammed Rafiq; Omar, Abdul Hafidz; Öchsner, Andreas

    2016-01-01

    This work identifies the characteristics of racket design parameters that influence racket performance.  It presents the finite element analysis of several designs of badminton rackets and compares them to experimental results for validation. Designing a racket requires a comprehensive understanding of racket performance characteristics. Essentially, racket performance is related to the sweet spot, which is the spot on the racket head that produces the most power and control when it strikes a shuttlecock. Determining a coefficient of restitution can help to identify the sweet spot on a racket. By analyzing several head shape designs, it becomes apparent that isometric head shape rackets produce better coefficients of restitution compared to oval and round ones. It is recommended that the racket design consist of low string tension, stiffer racket shafts and bigger head size in order to produce higher shuttlecock speed.

  6. Neutron activation analysis of trace elements in foodstuffs

    International Nuclear Information System (INIS)

    Schelenz, R.; Fischer, E.

    1976-05-01

    A neutron activation method for multielement determination in biological material was developed. The individual steps of the method include radiochemical processing as well as nondestructive techniques. In order to develop a high resolution gamma spectrometric method the indispensable assumptions were the application of Ge(Li)-semiconductor detectors, multi-channel pulse height analyzers and the use of electronic data evaluation with mini-computers for the automatic evaluation of complex gamma spectra. After radiochemical separation (RNAA) 33 elements can be determined in biological materials and by application of nondestructive, purely instrumental techniques (INAA) 25 elements. The time required for the analysis of 33 elements can be determined in biological materials and by application of nondestructive, purely instrumental techniques (INAA) 25 elements. The time required for the analysis of 33 elements is 4 days. The neutron activation method is used routinely for the determination of trace elements in foodstuffs and in the field of nutrition research. (orig.) [de

  7. Finite element analysis of inclined nozzle-plate junctions

    International Nuclear Information System (INIS)

    Dixit, K.B.; Seth, V.K.; Krishnan, A.; Ramamurthy, T.S.; Dattaguru, B.; Rao, A.K.

    1979-01-01

    Estimation of stress concentration at nozzle to plate or shell junctions is a significant problem in the stress analysis of nuclear reactors. The topic is a subject matter of extensive investigations and earlier considerable success has been reported on analysis for the cases when the nozzle is perpendicular to the plate or is radial to the shell. Analytical methods for the estimation of stress concentrations for the practical situations when the intersecting nozzle is inclined to the plate or is non-radial to the shell is rather scanty. Specific complications arise in dealing with the junction region when the nozzle with circular cross-section meets the non-circular cut-out on the plate or shell. In this paper a finite element analysis is developed for inclined nozzles and results are presented for nozzle-plate junctions. A method of analysis is developed with a view to achieving simultaneously accuracy of results and simplicity in the choice of elements and their connectivity. The circular nozzle is treated by axisymmetric conical shell elements. The nozzle portion in the region around the junction and the flat plate is dealt with by triangular flat shell elements. Special transition elements are developed for joining the flat shell elements with the axisymmetric elements under non-axisymmetric loading. A substructure method of analysis is adopted which achieves considerable economy in handling the structure and also conveniently combines the different types of elements in the structure. (orig.)

  8. PIXE methodology of rare earth element analysis and its applications

    International Nuclear Information System (INIS)

    Ma Xinpei

    1992-01-01

    The Proton Induced X-ray Emission (PIXE) methodology of rare earth element (REEs) analysis is discussed, including the significance of REE analysis, the principle of PIXE applied to REE, selection of characteristic X-ray for Lanthanide series elements, deconvolution of highly over lapped PIXE spectrum and minimum detection limit (MDL) of REEs. Some practical applications are presented. And the specialities of PIXE analysis to the high pure REE chemicals are discussed. (author)

  9. 2. Methods of elemental analysis of materials

    International Nuclear Information System (INIS)

    Musilek, L.

    1992-01-01

    The principles of activation analysis are outlined including the preparation of samples and reference materials, the choice of suitable activation sources, interfering effects, detection of radiation emitted and analysis of mixtures of emitters, and the potential of activation analysis in various fields of science and technology. The principles of X-ray fluorescence analysis and the associated instrumentation are also dealt with, and examples of applications are given. Described are also the physical nature of the Moessbauer effect, Moessbauer sources and spectrometers, and the applicability of this effect in physical research and in the investigation of iron-containing materials. (Z.S.). 1 tab., 20 figs., 90 refs

  10. Multi-element analysis of small biological samples

    International Nuclear Information System (INIS)

    Rokita, E.; Cafmeyer, J.; Maenhaut, W.

    1983-01-01

    A method combining PIXE and INAA was developed to determine the elemental composition of small biological samples. The method needs virtually no sample preparation and less than 1 mg is sufficient for the analysis. The method was used for determining up to 18 elements in leaves taken from Cracow Herbaceous. The factors which influence the elemental composition of leaves and the possible use of leaves as an environmental pollution indicator are discussed

  11. High accuracy 3D electromagnetic finite element analysis

    International Nuclear Information System (INIS)

    Nelson, E.M.

    1996-01-01

    A high accuracy 3D electromagnetic finite element field solver employing quadratic hexahedral elements and quadratic mixed-order one-form basis functions will be described. The solver is based on an object-oriented C++ class library. Test cases demonstrate that frequency errors less than 10 ppm can be achieved using modest workstations, and that the solutions have no contamination from spurious modes. The role of differential geometry and geometrical physics in finite element analysis will also be discussed

  12. X-ray fluorescent elemental analysis. Ch. 16

    International Nuclear Information System (INIS)

    Baryshev, V.; Kulipanov, G.; Skrinsky, A.

    1991-01-01

    X-ray fluorescence analysis (XFA) is used worldwide to define a quantitative content of the elements as well as to visualize the distribution of elements in different regions (element mapping). Utilization of synchrotron radiation (SR) to excite X-ray fluorescence enables the XFA method to be qualitatively improved. This chapter reviews the experimental work in especially the last decade (author). 71 refs.; 24 figs.; 3 tabs

  13. High accuracy 3D electromagnetic finite element analysis

    International Nuclear Information System (INIS)

    Nelson, Eric M.

    1997-01-01

    A high accuracy 3D electromagnetic finite element field solver employing quadratic hexahedral elements and quadratic mixed-order one-form basis functions will be described. The solver is based on an object-oriented C++ class library. Test cases demonstrate that frequency errors less than 10 ppm can be achieved using modest workstations, and that the solutions have no contamination from spurious modes. The role of differential geometry and geometrical physics in finite element analysis will also be discussed

  14. RENT CONTROL: A COMPARATIVE ANALYSIS

    Directory of Open Access Journals (Sweden)

    Sue-Mari Maass

    2012-11-01

    Full Text Available Recent case law shows that vulnerable, previously disadvantaged private sector tenants are currently facing eviction orders – and consequential homelessness – on the basis that their leases have expired. In terms of the case law it is evident that once their leases have expired, these households do not have access to alternative accommodation. In terms of the Constitution, this group of marginalised tenants have a constitutional right of access to adequate housing and a right to occupy land with legally secure tenure. The purpose of this article is to critically analyse a number of legislative interventions, and specifically rent control, that were imposed in various jurisdictions in order to provide strengthened tenure protection for tenants. The rationale for this analysis is to determine whether the current South African landlord-tenant regime is able to provide adequate tenure protection for vulnerable tenants and therefore in the process of transforming in line with the Constitution. The legal construction of rent control was adopted in pre-1994 South Africa, England and New York City to provide substantive tenure protection for tenants during housing shortages. These statutory interventions in the different private rental markets were justified on the basis that there was a general need to protect tenants against exploitation by landlords. However, the justification for the persistent imposition of rent control in New York City is different since it protects a minority group of financially weak tenants against homelessness. The English landlord-tenant regime highlights the importance of a well-structured social sector that can provide secure, long-term housing options for low-income households who are struggling to access the private rental sector. Additionally, the English rental housing framework shows that if the social sector is functioning as a "safety net" for low-income households, the private sector would be able to uphold

  15. The Constituent Elements of Comparative Education in Japan: A Comparison with North America

    Science.gov (United States)

    Yamada, Shoko

    2015-01-01

    This article, with the aim of identifying elements that constitute the characteristics of an academic space within comparative education, analyzes how comparative education has been discussed and practiced in Japan, based on a questionnaire completed by 264 members of the Japan Comparative Education Society and classification of articles published…

  16. Analysis of pipe mitred bends using beam models - by finite element method

    International Nuclear Information System (INIS)

    Salles, A.C.S.L. de.

    1984-01-01

    The formulation of a recently proposed displacement based straight pipe element for the analysis of pipe mitred bends is summarized in this work. The element kinematics includes axial, bending, torsional and ovalisation displacements, all varying cubically along the axis of the element. Interaction effects between angle adjoined straight pipe section are modeled including the appropriate additional strain terms in the stiffness matrix formulation and by using a penalty procedure to enforce continuity of pipe skin flexural rotations at the common helical edge. The element model capabilities are ilustrated in some sample analysis and the results are compared with other available experimental, analytical or more complex numerical models. (Author) [pt

  17. Determination of trace elements in biological material by neutron activation analysis

    International Nuclear Information System (INIS)

    Tran Van, L.; Teherani, D.K.

    1989-01-01

    Eighteen trace elements in biological materials [grass (Imperata cylindrica), mimosa plant (Mimosa pudica), rice] by neutron activation method were determined. In the comparative analysis the content of the same element was different in each material, although they were collected at the same place and the same sampling method was applied. (author) 4 refs.; 1 fig.; 1 tab

  18. Sensitivity analysis of the Galerkin finite element method neutron diffusion solver to the shape of the elements

    Energy Technology Data Exchange (ETDEWEB)

    Hosseini, Seyed Abolfaz [Dept. of Energy Engineering, Sharif University of Technology, Tehran (Iran, Islamic Republic of)

    2017-02-15

    The purpose of the present study is the presentation of the appropriate element and shape function in the solution of the neutron diffusion equation in two-dimensional (2D) geometries. To this end, the multigroup neutron diffusion equation is solved using the Galerkin finite element method in both rectangular and hexagonal reactor cores. The spatial discretization of the equation is performed using unstructured triangular and quadrilateral finite elements. Calculations are performed using both linear and quadratic approximations of shape function in the Galerkin finite element method, based on which results are compared. Using the power iteration method, the neutron flux distributions with the corresponding eigenvalue are obtained. The results are then validated against the valid results for IAEA-2D and BIBLIS-2D benchmark problems. To investigate the dependency of the results to the type and number of the elements, and shape function order, a sensitivity analysis of the calculations to the mentioned parameters is performed. It is shown that the triangular elements and second order of the shape function in each element give the best results in comparison to the other states.

  19. Nonlinear Finite Element Analysis of Shells with Large Aspect Ratio

    Science.gov (United States)

    Chang, T. Y.; Sawamiphakdi, K.

    1984-01-01

    A higher order degenerated shell element with nine nodes was selected for large deformation and post-buckling analysis of thick or thin shells. Elastic-plastic material properties are also included. The post-buckling analysis algorithm is given. Using a square plate, it was demonstrated that the none-node element does not have shear locking effect even if its aspect ratio was increased to the order 10 to the 8th power. Two sample problems are given to illustrate the analysis capability of the shell element.

  20. Application of trace element analysis to determine trace element concentrations in the field of medicine

    International Nuclear Information System (INIS)

    Kasperek, K.; Feinendegen, L.E.

    1976-01-01

    Applied trace elements research in medicine requires a sensitive and efficient technique of trace elements analysis such as, e.g., neutron activation analysis. Essential trace elements act as stabilisators (iron in haem), structural elements (silicium in fibrous tissue), in hormones (iodine in thyroid hormone), in vitamins (cobalt in vitamin B 12), and in enzymes. Most of the essential trace elements act as coenzymes or in coenzymes or directly as metabolic catalysators. For example, selenium deficiency in PKU and maple syrup patients receiving dietary treatment can be detected by determining the selenium content of the serum, while low selenium values in the whole blood indicate liver cirrhosis. Acrodermatitis enteropathica can be diagnosed by determinig zinc in the serum, and pancreatic insufficiency by determining zinc in the pancreatic juice. Zinc also plays a part in disturbances of growth, in the healing of wounds, and in the insulin metabolism. Cobalt is important in some types of anaemia and in myocardiopathies. Trace elements are also necessary in the treatment of diseases, e.g. iron cobalt in some types of anaemia, and zinc in the delayed healing of wounds in the postoperative phase and in acrodermatitis enteropathica. Chromium is now being tested for the treatment of diabetes mellitus, and fluorides may be of interest in the treatment of osteoporosis. Finally, trace elements are important in the aetiology of acute poisoning, in nutrition, and in environmental protection. (orig./AK) [de

  1. Application of trace element analysis to determine trace element concentrations in the field of medicine. [Neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Kasperek, K; Feinendegen, L E

    1976-01-01

    Applied trace elements research in medicine requires a sensitive and efficient technique of trace elements analysis, such as neutron activation analysis. Essential trace elements act as stabilizators (iron in haem), structural elements (silicon in fibrous tissue), in hormones (iodine in thyroid hormone), in vitamins (cobalt in vitamin B 12), and in enzymes. Most of the essential trace elements act as coenzymes or in coenzymes or directly as metabolic catalyzers. For example, selenium deficiency in PKU and maple syrup patients receiving dietary treatment can be detected by determining the selenium content of the serum, while low selenium values in the whole blood indicate liver cirrhosis. Acrodermatitis enteropathica can be diagnosed by determinig zinc in the serum, and pancreatic insufficiency by determining zinc in the pancreatic juice. Zinc also plays a part in disturbances of growth, in the healing of wounds, and in the insulin metabolism. Cobalt is important in some types of anaemia and in myocardiopathies. Trace elements are also necessary in the treatment of diseases, e.g. iron cobalt in some types of anaemia, and zinc in the delayed healing of wounds in the postoperative phase and in acrodermatitis enteropathica. Chromium is now being tested for the treatment of diabetes mellitus, and fluorides may be of interest in the treatment of osteoporosis. Finally, trace elements are important in the aetiology of acute poisoning, in nutrition, and in environmental protection.

  2. A Comparative Analysis of Outstanding Claim Reserves

    Directory of Open Access Journals (Sweden)

    Zlata Djuric

    2017-12-01

    Full Text Available The key processes in the business of insurance companies which define the financial viability of their business activities, as the most important element, are the adequate amount of technical reserves. A qualitative assessment of the technical reserves level is the basic support to the management of the key business processes and proper strategic and financial decision-making in order to maximize the viability, profitability, competitiveness, and further development of the company. Based on the data on the operations of an insurance company, within a single line of insurance, different, in practice, most frequently used methods were applied in order to determine the deviation amplitude of the projected amounts from the actual claims. Another direction of research focuses on actuarial practice in non-life insurance companies operating in the territory of the Republic of Serbia. The comparative analysis of the obtained projection points to the fact that the chosen methods, commonly used in actuarial practice in the Republic of Serbia, should be monitored and reviewed. The results of the multidirectional research and detection of the existing problems provide a useful framework and a stimulating mechanism, as well as the guidelines to improve the operations and better positioning of insurance in the commercial and economic environment of the Republic of Serbia.

  3. Thermomechanical finite element analysis of hot water boiler structure

    Directory of Open Access Journals (Sweden)

    Živković Dragoljub S.

    2012-01-01

    Full Text Available The paper presents an application of the Finite Elements Method for stress and strain analysis of the hot water boiler structure. The aim of the research was to investigate the influence of the boiler scale on the thermal stresses and strains of the structure of hot water boilers. Results show that maximum thermal stresses appear in the zone of the pipe carrying wall of the first reversing chamber. This indicates that the most critical part of the boiler are weld spots of the smoke pipes and pipe carrying plate, which in the case of significant scale deposits can lead to cracks in the welds and water leakage from the boiler. The nonlinear effects were taken into account by defining the bilinear isotropic hardening model for all boiler elements. Temperature dependency was defined for all relevant material properties, i. e. isotropic coefficient of thermal expansion, Young’s modulus, and isotropic thermal conductivity. The verification of the FEA model was performed by comparing the measured deformations of the hot water boiler with the simulation results. As a reference object, a Viessmann - Vitomax 200 HW boiler was used, with the installed power of 18.2 MW. CAD modeling was done within the Autodesk Inventor, and stress and strain analysis was performed in the ANSYS Software.

  4. Convergence analysis of spectral element method for electromechanical devices

    NARCIS (Netherlands)

    Curti, M.; Jansen, J.W.; Lomonova, E.A.

    2017-01-01

    This paper concerns the comparison of the performance of the Spectral Element Method (SEM) and the Finite Element Method (FEM) for a magnetostatic problem. The convergence of the vector magnetic potential, the magnetic flux density, and the total stored energy in the system is compared with the

  5. Convergence analysis of spectral element method for magnetic devices

    NARCIS (Netherlands)

    Curti, M.; Jansen, J.W.; Lomonova, E.A.

    2018-01-01

    This paper concerns the comparison of the performance of the Spectral Element Method (SEM) and the Finite Element Method (FEM) for modeling a magnetostatic problem. The convergence of the vector magnetic potential, the magnetic flux density, and the total stored energy in the system is compared with

  6. Finite element stress analysis of brick-mortar masonry under ...

    African Journals Online (AJOL)

    Stress analysis of a brick-mortar couplet as a substitute for brick wall structure has been performed by finite element method, and algorithm for determining the element stiffness matrix for a plane stress problem using the displacement approach was developed. The nodal displacements were derived for the stress in each ...

  7. Trace elements in Australian opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Fardy, J.J.

    1994-01-01

    Neutron activation analysis was used to determine the concentration of trace elements in 42 samples of black, grey and white opals taken from a number of recognised Australian field. The results were evaluated to determine if a relationship exited between trace element content and opal colour. (author) 12 refs.; 12 figs.; 3 tabs

  8. Probing Trace-elements in Bitumen by Neutron Activation Analysis

    NARCIS (Netherlands)

    Nahar, S.N.; Schmets, A.J.M.; Scarpas, Athanasios

    Trace elements and their concentrations play an important role in both chemical and physical properties of bitumen. Instrumental Neutron Activation Analysis (INAA) has been applied to determine the concentration of trace elements in bitumen. This method requires irradiation of the material with

  9. Comparative skull morphology of uropeltid snakes (Alethinophidia: Uropeltidae with special reference to disarticulated elements and variation.

    Directory of Open Access Journals (Sweden)

    Jennifer C Olori

    Full Text Available Uropeltids form a diverse clade of highly derived, fossorial snakes that, because of their phylogenetic position among other alethinophidian lineages, may play a key role in understanding the early evolution of cranial morphology in snakes. We include detailed osteological descriptions of crania and mandibles for eight uropeltid species from three nominal genera (Uropeltis, Rhinophis, and Brachyophidium and emphasize disarticulated elements and the impact of intraspecific variation on previously proposed morphological characters used for phylogenetic analysis. Preliminary analysis of phylogenetic relationships strongly supports a clade composed exclusively of species of Plectrurus, Uropeltis, and Rhinophis. However, monophyly of each of those genera and Melanophidium is not upheld. There is moderate support that Sri Lankan species (e.g., Rhinophis and Uropeltis melanogaster are monophyletic with respect to Indian uropeltids. Previously proposed characters that are phylogenetically informative include the shape of the nasals, length of the occipital condyle, level of development of the posteroventral process of the dentary, and participation of the parietal in the optic foramen. Additionally, thirty new features that may be systematically informative are identified and described, but were not verified for their utility. Such verification must await availability of additional disarticulated cranial material from a larger sample of taxa. All characters require further testing through increased focus on sources and patterns of intraspecific variation, inclusion of broader taxonomic samples in comparative studies, and exploration of skeletal development, sexual dimorphism, and biogeographic patterns. Additionally, trends in the relative enlargement of the sensory capsules, reduction in cranial ossification and dentition, fusion of elements, and the appearance of novel morphological conditions, such as the structure and location of the suspensorium

  10. Introduction to finite element analysis using MATLAB and Abaqus

    CERN Document Server

    Khennane, Amar

    2013-01-01

    There are some books that target the theory of the finite element, while others focus on the programming side of things. Introduction to Finite Element Analysis Using MATLAB(R) and Abaqus accomplishes both. This book teaches the first principles of the finite element method. It presents the theory of the finite element method while maintaining a balance between its mathematical formulation, programming implementation, and application using commercial software. The computer implementation is carried out using MATLAB, while the practical applications are carried out in both MATLAB and Abaqus. MA

  11. Seismic Analysis of Concrete Dam by Using Finite Element Method

    Directory of Open Access Journals (Sweden)

    Rozaina Ismail

    2017-01-01

    Full Text Available This paper reports a brief study on linear seismic analysis of Sg. Kinta Concrete Dam. The analysis was conducted in order to determine the performance and behaviour of the dam under seismic excitation. The dam was modelled as two-dimensional and developed based on the design drawing that is obtained from Angkasa Consulting Services Sdn. Bhd. The seismic analysis of the dam is conducted using finite element analysis software package LUSAS 14.3 and the dam has been analyse as a plain stress problem with a linear consideration. A set of historic data, with E1 Centro earthquake acceleration of about 0.50g is used as an earthquake excitation. The natural frequency and mode shape up to fifth mode of the dam has been obtained from the analysis to show the differences of the stress and deformation between each mode. The maximum horizontal and vertical stress of Sg. Kinta dam was found and the distribution of them was discussed in form of contours. The deformation of the dam were also been discussed by comparing the maximum displacement for each mode shaped.

  12. Shakedown analysis by finite element incremental procedures

    International Nuclear Information System (INIS)

    Borkowski, A.; Kleiber, M.

    1979-01-01

    It is a common occurence in many practical problems that external loads are variable and the exact time-dependent history of loading is unknown. Instead of it load is characterized by a given loading domain: a convex polyhedron in the n-dimensional space of load parameters. The problem is then to check whether a structure shakes down, i.e. responds elastically after a few elasto-plastic cycles, or not to a variable loading as defined above. Such check can be performed by an incremental procedure. One should reproduce incrementally a simple cyclic process which consists of proportional load paths that connect the origin of the load space with the corners of the loading domain. It was proved that if a structure shakes down to such loading history then it is able to adopt itself to an arbitrary load path contained in the loading domain. The main advantage of such approach is the possibility to use existing incremental finite-element computer codes. (orig.)

  13. Optical strain measurements and its finite element analysis of cold ...

    African Journals Online (AJOL)

    International Journal of Engineering, Science and Technology ... Online video images of square grid were recorded during the deformation ... Finite element software ANSYS has been applied for the analysis of the upset forming process.

  14. Elemental analysis of combustion products by neutron activation

    International Nuclear Information System (INIS)

    Heft, R.E.; Koszykowski, R.F.

    1980-01-01

    This paper gives a brief description of the neutron activation analysis method, which is being used to determine the elemental profile of combustion products from coal-fired power plants, oil shale retorting, and underground coal gasification

  15. Finite element analysis of thermal stress distribution in different ...

    African Journals Online (AJOL)

    Nigerian Journal of Clinical Practice • Jan-Feb 2016 • Vol 19 • Issue 1. Abstract ... Key words: Amalgam, finite element method, glass ionomer cement, resin composite, thermal stress ... applications for force analysis and assessment of different.

  16. A study on the nonlinear finite element analysis of reinforced concrete structures: shell finite element formulation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Jin; Seo, Jeong Moon

    2000-08-01

    The main goal of this research is to establish a methodology of finite element analysis of containment building predicting not only global behaviour but also local failure mode. In this report, we summerize some existing numerical analysis techniques to be improved for containment building. In other words, a complete description of the standard degenerated shell finite element formulation is provided for nonlinear stress analysis of nuclear containment structure. A shell finite element is derived using the degenerated solid concept which does not rely on a specific shell theory. Reissner-Mindlin assumptions are adopted to consider the transverse shear deformation effect. In order to minimize the sensitivity of the constitutive equation to structural types, microscopic material model is adopted. The four solution algorithms based on the standard Newton-Raphson method are discussed. Finally, two numerical examples are carried out to test the performance of the adopted shell medel.

  17. A study on the nonlinear finite element analysis of reinforced concrete structures: shell finite element formulation

    International Nuclear Information System (INIS)

    Lee, Sang Jin; Seo, Jeong Moon

    2000-08-01

    The main goal of this research is to establish a methodology of finite element analysis of containment building predicting not only global behaviour but also local failure mode. In this report, we summerize some existing numerical analysis techniques to be improved for containment building. In other words, a complete description of the standard degenerated shell finite element formulation is provided for nonlinear stress analysis of nuclear containment structure. A shell finite element is derived using the degenerated solid concept which does not rely on a specific shell theory. Reissner-Mindlin assumptions are adopted to consider the transverse shear deformation effect. In order to minimize the sensitivity of the constitutive equation to structural types, microscopic material model is adopted. The four solution algorithms based on the standard Newton-Raphson method are discussed. Finally, two numerical examples are carried out to test the performance of the adopted shell medel

  18. Trace and ultratrace level elemental and speciation analysis

    International Nuclear Information System (INIS)

    Arunachalam, J.

    2012-01-01

    Accurate determination of elements present at parts per million and billion levels in various matrices is a growing requirement in different fields. In environmental sciences various trace elements need to be analyzed so as establish the dispersal models of pollutants or the adequacy of effluent treatment prior to discharge into water bodies. The issues of bioaccumulation and magnification are important in aquatic systems. In nutrition and biochemistry one has to establish the bio-availability of essential and toxic elemental species as toxic elements prevent assimilation of essential elements. Fission and fusion technologies use a variety of structural materials requiring many trace elements to be present at levels strictly below the specified levels. Ultra-pure bulk semiconductor materials are required for fabrication devices. In metallurgy and materials sciences too, various trace elements are known to influence the properties. In the emerging fields like nanotechnology, it is necessary to understand the passage and accumulation of nano-particles inside the cells, through trace analysis. Many analytical techniques exist which can provide the concentration information in the bulk materials with good accuracy. They include ICP-AES, FAAS, and ICP-MS, which are solution based techniques. Direct solid state analytical techniques are Glow Discharge Mass Spectrometry (GDMS) and XRF. Accelerator based ion-beam analysis techniques can provide information on concentration and depth profiles of different elements in layered structures. Hyphenated techniques such as HPLC/lC-ICPMS, are helpful in identifying various chemical oxidation states in which a given element might be present in a matrix, which is termed as speciation analysis. This presentation will include the existing analytical competencies and the laboratory requirements for trace and ultra trace element elemental and speciation analyses and their applications. (author)

  19. Finite element analysis of mechanical stability of coarsened nanoporous gold

    International Nuclear Information System (INIS)

    Cho, Hoon-Hwe; Chen-Wiegart, Yu-chen Karen; Dunand, David C.

    2016-01-01

    The mechanical stability of nanoporous gold (np-Au) at various stages of thermal coarsening is studied via finite element analysis under volumetric compression using np-Au architectures imaged via X-ray nano-tomography. As the np-Au is coarsened thermally over ligament sizes ranging from 185 to 465 nm, the pore volume fraction is determinant for the mechanical stability of the coarsened np-Au, unlike the curvature and surface orientation of the ligaments. The computed Young's modulus and yield strength of the structures are compared with the Gibson–Ashby model. The geometry of the structures determines the locations where stress concentrations occur at the onset of yielding.

  20. Analysis and design of lumped element Marchand baluns

    DEFF Research Database (Denmark)

    Johansen, Tom Keinicke; Krozer, Viktor

    2008-01-01

    In this paper a novel design procedure for lumped element Marchand baluns is proposed. An analysis is performed on the balun structure in order to determine the conditions for ideal balun performance in terms of the lumped element values. The analysis is verified by two broadband designs centered...... around 22.75 GHz and differing only in terms of their impedance transformation ratio. EM simulation results on our proposed lumped element Marchand balun structure predicts an insertion loss of 4 dB and return loss of 40 dB at the design frequency of 22.75 GHz. The amplitude and phase imbalance...

  1. Finite element analysis of tubular joints in offshore structures ...

    African Journals Online (AJOL)

    ... representing a 2-D model of the joint between the brace and the chord walls. This was subsequently followed but finite element analysis of six tubular joints. A global analysis was initially undertaken, then the submodel analysis carried in the areas of stress concentration. Journal of Civil Engineering, JKUAT (2001) Vol 6, ...

  2. Gothic elements in contemporary detective story : Matthew Gregory Lewis and Minette Walters compared

    Directory of Open Access Journals (Sweden)

    Vesna Marinko

    2009-12-01

    Full Text Available One of the most shocking Gothic novels was written by Matthew Gregory Lewis in 1796. His Gothic novel The Monk contains all the typical Gothic elements such as a ruined castle, aggressive villain, women in distress, the atmosphere of terror and horror and a lot more. This article analyses and compares to what extent the Gothic elements of the late 18th century survived in the contemporary detective story The Ice House (1993 written by Minette Walters and how these elements have changed.

  3. ANALYSIS OF DESIGN ELEMENTS IN SKI SUITS

    Directory of Open Access Journals (Sweden)

    Birsen Çileroğlu

    2014-06-01

    Full Text Available Popularity of Ski Sport in 19th century necessitated a new perspective on protective skiing clothing ag ainst the mountain climates and excessive cold. Winter clothing were the basis of ski attire during this period. By the beginning of 20th century lining cloth were used to minimize the wind effect. The difference between the men and women’s ski attire of the time consisted of a knee - length skirts worn over the golf trousers. Subsequent to the First World War, skiing suit models were influenced by the period uniforms and the producers reflected the fashion trends to the ski clothing. In conformance with th e prevailing trends, ski trousers were designed and produced for the women thus leading to reduction in gender differences. Increases in the ski tourism and holding of the first winter olympics in 1924 resulted in variations in ski attires, development of design characteristics, growth in user numbers, and enlargement of production capacities. Designers emphasized in their collections combined presence of elegance and practicality in the skiing attire. In 1930s, the ski suits influenced by pilots’ uniforms included characteristics permitting freedom of motion, and the design elements exhibited changes in terms of style, material and aerodynamics. In time, the ski attires showed varying design features distinguishing professionals from the amateurs. While protective functionality was primary consideration for the amateurs, for professionals the aerodynamic design was also a leading factor. Eventually, the increased differences in design characteristics were exhibited in ski suit collections, World reknown brands were formed, production and sales volumes showed significant rise. During 20th century the ski suits influenced by fashion trends to acquire unique styles reached a position of dominance to impact current fashion trends, and apart from sports attir es they became a style determinant in the clothing of cold climates. Ski suits

  4. PIXE-quantified AXSIA: Elemental mapping by multivariate spectral analysis

    International Nuclear Information System (INIS)

    Doyle, B.L.; Provencio, P.P.; Kotula, P.G.; Antolak, A.J.; Ryan, C.G.; Campbell, J.L.; Barrett, K.

    2006-01-01

    Automated, nonbiased, multivariate statistical analysis techniques are useful for converting very large amounts of data into a smaller, more manageable number of chemical components (spectra and images) that are needed to describe the measurement. We report the first use of the multivariate spectral analysis program AXSIA (Automated eXpert Spectral Image Analysis) developed at Sandia National Laboratories to quantitatively analyze micro-PIXE data maps. AXSIA implements a multivariate curve resolution technique that reduces the spectral image data sets into a limited number of physically realizable and easily interpretable components (including both spectra and images). We show that the principal component spectra can be further analyzed using conventional PIXE programs to convert the weighting images into quantitative concentration maps. A common elemental data set has been analyzed using three different PIXE analysis codes and the results compared to the cases when each of these codes is used to separately analyze the associated AXSIA principal component spectral data. We find that these comparisons are in good quantitative agreement with each other

  5. Finite element analysis of 2-Station hip himulator

    Science.gov (United States)

    Fazli, M. I. M.; Yahya, A.; Shahrom, A.; Nawawi, S. W.; Zainudin, M. R.; Nazarudin, M. S.

    2017-10-01

    This paper presented the analysis of materials and design architecture of 2-station hip simulator. Hip simulator is a machine used to conduct the joint and wear test of hip prosthetic. In earlier work, the hip simulator was modified and some improvement were made by using SolidWorks software. The simulator consists of 3DOF which controlled by separate stepper motor and a static load that set up by manual method in each station. In this work, finite element analysis (FEA) of hip simulator was implemented to analyse the structure of the design and selected materials used for simulator component. The analysis is completed based on two categories which are safety factor and stress tests. Both design drawing and FEA was done using SolidWorks software. The study of the two categories is performed by applying the peak load up to 4000N on the main frame that is embedded with metal-on-metal hip prosthesis. From FEA, the value of safety factor and degree of stress formation are successfully obtained. All the components exceed the value of 2 for safety factor analysis while the degree of stress formation shows higher value compare to the yield strength of the material. With this results, it provides information regarding part of simulator which are susceptible to destruct. Besides, the results could be used for design improvement and certify the stability of the hip simulator in real application.

  6. Finite Element Analysis of Circular Plate using SolidWorks

    International Nuclear Information System (INIS)

    Kang, Yeo Jin; Jhung, Myung Jo

    2011-01-01

    Circular plates are used extensively in mechanical engineering for nuclear reactor internal components. The examples in the reactor vessel internals are upper guide structure support plate, fuel alignment plate, lower support plate etc. To verify the structural integrity of these plates, the finite element analyses are performed, which require the development of the finite element model. Sometimes it is very costly and time consuming to make the model especially for the beginners who start their engineering job for the structural analysis, necessitating a simple method to develop the finite element model for the pursuing structural analysis. Therefore in this study, the input decks are generated for the finite element analysis of a circular plate as shown in Fig. 1, which can be used for the structural analysis such as modal analysis, response spectrum analysis, stress analysis, etc using the commercial program Solid Works. The example problems are solved and the results are included for analysts to perform easily the finite element analysis of the mechanical plate components due to various loadings. The various results presented in this study would be helpful not only for the benchmark calculations and results comparisons but also as a part of the knowledge management for the future generation of young designers, scientists and computer analysts

  7. Analysis of concrete beams using applied element method

    Science.gov (United States)

    Lincy Christy, D.; Madhavan Pillai, T. M.; Nagarajan, Praveen

    2018-03-01

    The Applied Element Method (AEM) is a displacement based method of structural analysis. Some of its features are similar to that of Finite Element Method (FEM). In AEM, the structure is analysed by dividing it into several elements similar to FEM. But, in AEM, elements are connected by springs instead of nodes as in the case of FEM. In this paper, background to AEM is discussed and necessary equations are derived. For illustrating the application of AEM, it has been used to analyse plain concrete beam of fixed support condition. The analysis is limited to the analysis of 2-dimensional structures. It was found that the number of springs has no much influence on the results. AEM could predict deflection and reactions with reasonable degree of accuracy.

  8. Dynamic relaxation method in analysis of reinforced concrete bent elements

    Directory of Open Access Journals (Sweden)

    Anna Szcześniak

    2015-12-01

    Full Text Available The paper presents a method for the analysis of nonlinear behaviour of reinforced concrete bent elements subjected to short-term static load. The considerations in the range of modelling of deformation processes of reinforced concrete element were carried out. The method of structure effort analysis was developed using the finite difference method. The Dynamic Relaxation Method, which — after introduction of critical damping — allows for description of the static behaviour of a structural element, was used to solve the system of nonlinear equilibrium equations. In order to increase the method effectiveness in the range of the post-critical analysis, the Arc Length Parameter on the equilibrium path was introduced into the computational procedure.[b]Keywords[/b]: reinforced concrete elements, physical nonlinearity, geometrical nonlinearity, dynamic relaxation method, arc-length method

  9. Analysis of trace elements in opal using PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Hinrichs, Ruth, E-mail: ruth.hinrichs@ufrgs.br [Instituto de Geociências, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil); Programa de Pós-graduação em Física, UFRGS, Porto Alegre, RS (Brazil); Bertol, A.P.L. [Programa de Pós-graduação em Física, UFRGS, Porto Alegre, RS (Brazil); Vasconcellos, M.A.Z. [Programa de Pós-graduação em Física, UFRGS, Porto Alegre, RS (Brazil); Instituto de Física, UFRGS, Porto Alegre, RS (Brazil)

    2015-11-15

    Particle induced X-ray emission (PIXE) analysis is particularly important for the analysis of trace elements of precious samples, being one of the few methods to determine elements with ppm concentration that does not affect sample integrity. A PIXE methodology for trace element analysis in opal was developed. To avoid detector count saturation due to the high number of Si-Kα X-rays generated in the sample, several filters were employed to optimize the reduction of the Si-Kα signal, while maintaining acceptable intensities of the other relevant X-ray lines. Two proton beam energies were tested, to establish the signal to noise ratio in different X-ray energies. Spectra were fitted with the software GUPIX, using a matrix composition determined with electron beam excited energy dispersive X-ray spectrometry. Above the energy of the silicon X-ray, several trace elements were quantified.

  10. Correct use of Membrane Elements in Structural Analysis

    Directory of Open Access Journals (Sweden)

    Rothman Timothy

    2016-01-01

    Full Text Available Structural analysis of consumer electronic devices such as phones and tablets involves Finite Element Analysis (FEA. Dynamic loading conditions such as device dropping and bending dictate accurate FEA models to reduce design risk in many areas. The solid elements typically used in structural analysis do not have integration points on the surface. The outer surface is of most interest because that is where the cracks start. Analysts employ a post processing trick through using membranes to bring accurate stress/strain results to the surface. This paper explains numerical issues with implementation of membranes and recommends a methodology for accurate structural analysis.

  11. Quantitative analysis of light elements in thick samples by PIGE

    International Nuclear Information System (INIS)

    Mateus, R.; Jesus, A.P.; Ribeiro, J.P.

    2004-01-01

    PIGE analysis of thick and intermediate samples is usually performed with the help of standards, but this method gives only good results when the standard is very similar to the sample to be analysed. In this work, we present an alternative method for PIGE analysis of light elements in thick samples. This method is based on a code that integrates the nuclear reaction excitation function along the depth of the sample. For the integration procedure the sample is divided in sublayers, defined by the energy steps that were used to measure accurately the excitation function. This function is used as input. Within each sublayer the stopping power cross-sections may be assumed as constant. With these two conditions the calculus of the contribution of each sublayer for the total yield becomes an easy task. This work presents results for the analysis of lithium, boron, fluorine and sodium in thick samples. For this purpose, excitation functions of the reactions 7 Li(p,p ' γ) 7 Li, 19 F(p,p ' γ) 19 F, 10 B(p,αγ) 7 Be and 23 Na(p,p ' γ) 23 Na were employed. Calculated γ-ray yields were compared, at several proton energy values, with experimental yields for thick samples made of inorganic compounds of the referred elements. The agreement is better than 7.5%. Taking into consideration the experimental uncertainty of the measured yields and the errors related to the stopping power values used, this agreement shows that effects as the beam energy straggling, ignored in the calculation, seem to play a minor role

  12. Using the ion microprobe mass analyser for trace element analysis

    International Nuclear Information System (INIS)

    Schilling, J.H.

    1978-01-01

    Most techniques for the analysis of trace elements are capable of determining the concentrations in a bulk sample or solution, but without reflecting their distribution. In a bulk analysis therefore elements which occur in high concentration in a few precipitates would still be considered trace elements even though their local concentration greatly exceed the normally accepted trace elements concentration limit. Anomalous distribution is also shown by an oxide layer, a few hundred Angstrom thick, on an aluminium sample. A low oxide concentration would be reported if it were included in the bulk analysis, which contradicts the high surface concentration. The importance of a knowledge of the trace element distribution is therefore demonstrated. Distributional trace element analysis can be carried out using the ion microprobe mass analyser (IMMA). Since the analytical technique used in this instrument, namely secondary ion mass spectrometry (SIMS), is not universally appreciated, the instrument and its features will be described briefly followed by a discussion of quantitative analysis and the related subjects of detection limit and sample consumption. Finally, a few examples of the use of the instrument are given

  13. Elements of stochastic calculus and analysis

    CERN Document Server

    Stroock, Daniel W

    2018-01-01

    This book gives a somewhat unconventional introduction to stochastic analysis. Although most of the material covered here has appeared in other places, this book attempts to explain the core ideas on which that material is based. As a consequence, the presentation is more an extended mathematical essay than a ``definition, lemma, theorem'' text. In addition, it includes several topics that are not usually treated elsewhere. For example, Wiener's theory of homogeneous chaos is discussed, Stratovich integration is given a novel development and applied to derive Wong and Zakai's approximation theorem, and examples are given of the application of Malliavin's calculus to partial differential equations. Each chapter concludes with several exercises, some of which are quite challenging. The book is intended for use by advanced graduate students and research mathematicians who may be familiar with many of the topics but want to broaden their understanding of them.

  14. Finite element analysis of a model scale footing on clean and oil contaminated sand

    International Nuclear Information System (INIS)

    Evgin, E.; Boulon, M.; Das, B.M.

    1995-01-01

    The effects of oil contamination on the behavior of a model scale footing is determined. Tests are carried out with both clean and oil contaminated sand. The data show that the bearing capacity of the footing is reduced significantly as a result of oil contamination. A finite element analysis is performed to calculate the bearing capacity of the footing and the results are compared with the experimental data. The significance of using an interface element in the analysis is discussed

  15. High sensitivity analysis of atmospheric gas elements

    International Nuclear Information System (INIS)

    Miwa, Shiro; Nomachi, Ichiro; Kitajima, Hideo

    2006-01-01

    We have investigated the detection limit of H, C and O in Si, GaAs and InP using a Cameca IMS-4f instrument equipped with a modified vacuum system to improve the detection limit with a lower sputtering rate We found that the detection limits for H, O and C are improved by employing a primary ion bombardment before the analysis. Background levels of 1 x 10 17 atoms/cm 3 for H, of 3 x 10 16 atoms/cm 3 for C and of 2 x 10 16 atoms/cm 3 for O could be achieved in silicon with a sputtering rate of 2 nm/s after a primary ion bombardment for 160 h. We also found that the use of a 20 K He cryo-panel near the sample holder was effective for obtaining better detection limits in a shorter time, although the final detection limits using the panel are identical to those achieved without it

  16. High sensitivity analysis of atmospheric gas elements

    Energy Technology Data Exchange (ETDEWEB)

    Miwa, Shiro [Materials Analysis Lab., Sony Corporation, 4-16-1 Okata, Atsugi 243-0021 (Japan)]. E-mail: Shiro.Miwa@jp.sony.com; Nomachi, Ichiro [Materials Analysis Lab., Sony Corporation, 4-16-1 Okata, Atsugi 243-0021 (Japan); Kitajima, Hideo [Nanotechnos Corp., 5-4-30 Nishihashimoto, Sagamihara 229-1131 (Japan)

    2006-07-30

    We have investigated the detection limit of H, C and O in Si, GaAs and InP using a Cameca IMS-4f instrument equipped with a modified vacuum system to improve the detection limit with a lower sputtering rate We found that the detection limits for H, O and C are improved by employing a primary ion bombardment before the analysis. Background levels of 1 x 10{sup 17} atoms/cm{sup 3} for H, of 3 x 10{sup 16} atoms/cm{sup 3} for C and of 2 x 10{sup 16} atoms/cm{sup 3} for O could be achieved in silicon with a sputtering rate of 2 nm/s after a primary ion bombardment for 160 h. We also found that the use of a 20 K He cryo-panel near the sample holder was effective for obtaining better detection limits in a shorter time, although the final detection limits using the panel are identical to those achieved without it.

  17. Thermomechanical analysis of nuclear fuel elements

    International Nuclear Information System (INIS)

    Hernandez L, H.

    1997-01-01

    This work presents development of a code to obtain the thermomechanical analysis of fuel rods in the fuel assemblies inserted in the core of BWR reactors. The code uses experimental correlations developed in several laboratories. The development of the code is divided in two parts: a) the thermal part and b) the mechanical part, extending both the fuel and the cladding materials. The thermal part consists of finding the radial distribution of temperatures in the pellet, from the fuel centerline up to the coolant, along the total active length, considering one and two phase flow in the coolant, as a result of the pressure drop in the system. The mechanical part analyzes the effects of temperature gradients, pressure and irradiation, to which the fuel rod is subjected. The strains produced by swelling, creep and thermal stress in the fuel material are analyzed. In the same way the strains in the cladding are analyzed, considering the effects produced by the pressure exerted on the cladding by pellet swelling, by the pressure caused by fission gas release toward the cavities, and by the strain produced on the cladding by the pressure changes of the system. (Author)

  18. Perspectives on clinical possibility: elements of analysis.

    Science.gov (United States)

    Chiffi, Daniele; Zanotti, Renzo

    2016-08-01

    Possibility is one of the most common modalities in reasoning and argumentation. Various kinds of modal concepts have been identified in philosophical and logical discussion of the metaphysics of modality. We focus here on the concept of clinical possibility. A critical analysis of what is intended as clinical possibility has not yet received sufficient examination, although the concept is extensively used in clinical reasoning. We present arguments to emphasize some desirable features associated with the concept of clinical possibility. We argue that almost all clinical possibilities are potentialities, that is, possibilities that may be actualized by effective, appropriate and feasible interventions. However, in some limited cases, even mere possibilities - which may or may not be actualized, since we do not have the required knowledge - may be involved in clinical reasoning, and we present some examples in this paper. We then introduce some basic views on the nature of possibility showing their validity and limitations when applied to the concept of clinical possibility. Lastly, we conjecture that clinical possibility is a normative modality that can be formalized in a multimodal system with epistemic and deontic logical operators. © 2015 John Wiley & Sons, Ltd.

  19. Finite element modelling of FRC beams containing PVA and Basalt fibres: A comparative study

    Science.gov (United States)

    Ayub, Tehmina; Khan, Sadaqat Ullah

    2017-09-01

    The endeavour of current study is to compare the flexural behaviour and three dimensional (3D) finite element analysis (FEA) and the results of FEM are compared with the experimental results of 07 HPFRC beams. Out of seven (07), 01 beam of plain concrete without fibres was cast as a control beam. Three (03) beams containing 1, 2 and 3% volume of PVA fibres were prepared by using HPFRC mixes while, the remaining other three (03) beams were prepared using HPFRC mixes containing 1, 2 and 3% volume of Basalt fibres. In order to ensure flexural failure, three-point bending load was applied at the mid span of all beams. The maximum flexural load and corresponding deflection and strains at the mid span attained prior to the failure were obtained as flexural test results. The FEM results were obtained by simulating all beams in ATENA 3D program and verified through flexural test results. Both of the results of FEM and Experiment showed good agreement with each other.

  20. A refined element-based Lagrangian shell element for geometrically nonlinear analysis of shell structures

    Directory of Open Access Journals (Sweden)

    Woo-Young Jung

    2015-04-01

    Full Text Available For the solution of geometrically nonlinear analysis of plates and shells, the formulation of a nonlinear nine-node refined first-order shear deformable element-based Lagrangian shell element is presented. Natural co-ordinate-based higher order transverse shear strains are used in present shell element. Using the assumed natural strain method with proper interpolation functions, the present shell element generates neither membrane nor shear locking behavior even when full integration is used in the formulation. Furthermore, a refined first-order shear deformation theory for thin and thick shells, which results in parabolic through-thickness distribution of the transverse shear strains from the formulation based on the third-order shear deformation theory, is proposed. This formulation eliminates the need for shear correction factors in the first-order theory. To avoid difficulties resulting from large increments of the rotations, a scheme of attached reference system is used for the expression of rotations of shell normal. Numerical examples demonstrate that the present element behaves reasonably satisfactorily either for the linear or for geometrically nonlinear analysis of thin and thick plates and shells with large displacement but small strain. Especially, the nonlinear results of slit annular plates with various loads provided the benchmark to test the accuracy of related numerical solutions.

  1. Investigation of Shear Stud Performance in Flat Plate Using Finite Element Analysis

    Directory of Open Access Journals (Sweden)

    T.S. Viswanathan

    2014-09-01

    Full Text Available Three types of shear stud arrangement, respectively featuring an orthogonal, a radial and a critical perimeter pattern, were evaluated numerically. A numerical investigation was conducted using the finite element software ABAQUS to evaluate their ability to resist punching shear in a flat plate. The finite element analysis here is an application of the nonlinear analysis of reinforced concrete structures using three-dimensional solid finite elements. The nonlinear characteristics of concrete were achieved by employing the concrete damaged plasticity model in the finite element program. Transverse shear stress was evaluated using finite element analysis in terms of shear stress distribution for flat plate with and without shear stud reinforcement. The model predicted that shear studs placed along the critical perimeter are more effective compared to orthogonal and radial patterns.

  2. Investigation of the Behavior of Steel Shear Walls Using Finite Elements Analysis

    Directory of Open Access Journals (Sweden)

    K. Abubakri

    2016-10-01

    Full Text Available Currently, steel shear walls are considered by engineers as an economic method against lateral loads imposed by wind and earthquake in tall structures. Accordingly, there is a growing need to develop accurate methods alongside approximation methods to estimate the behavior of these structural elements. The finite element technique is one of the strongest numerical methods in analysis of solid mechanics problems. Finite element analysis however requires high technical knowledge of the behavioral models of materials. Therefore, it is less used by designers for certain structural elements such as steel shear walls. This study examines the failure mechanism of steel shear walls using finite elements analysis and validates this modeling by comparing the results with experimental studies.

  3. Elemental content of Vietnamese rice. Part 2. Multivariate data analysis.

    Science.gov (United States)

    Kokot, S; Phuong, T D

    1999-04-01

    Rice samples were obtained from the Red River region and some other parts of Vietnam as well as from Yanco, Australia. These samples were analysed for 14 elements (P, K, Mg, Ca, Mn, Zn, Fe, Cu, Al, Na, Ni, As, Mo and Cd) by ICP-AES, ICP-MS and FAAS as described in Part 1. This data matrix was then submitted to multivariate data analysis by principal component analysis to investigate the influences of environmental and crop cultivation variables on the elemental content of rice. Results revealed that geographical location, grain variety, seasons and soil conditions are the most likely significant factors causing changes in the elemental content between the rice samples. To assess rice quality according to its elemental content and physio-biological properties, a multicriteria decision making method (PROMETHEE) was applied. With the Vietnamese rice, the sticky rice appeared to contain somewhat higher levels of nutritionally significant elements such as P, K and Mg than the non-sticky rice. Also, rice samples grown during the wet season have better levels of nutritionally significant mineral elements than those of the dry season, but in general, the wet season seemed to provide better overall elemental and physio-biological rice quality.

  4. A finite-element for the analysis of shell intersections

    International Nuclear Information System (INIS)

    Koves, W.J.; Nair, S.

    1994-01-01

    The analysis of discontinuity stresses at shell intersections is a problem of great importance in several major industries. Some of the major areas of interest are pressure-containing equipment, such as reactors and piping, in the nuclear and fossil power industry; pressure vessels and heat exchangers in the petrochemical industry; bracing in offshore oil platforms; and aerospace structures. A specialized shell-intersection finite element, which is compatible with adjoining shell elements, has been developed that has the capability of physically representing the complex three-dimensional geometry and stress state at shell intersections. The element geometry is a contoured shape that matches a wide variety of practical nozzle configurations used in ASME Code pressure vessel construction, and allows computational rigor. A closed-form theory of elasticity solution was used to compute the stress state and strain energy in the element. The concept of an energy-equivalent nodal displacement and force vector set was then developed to allow complete compatibility with adjoining shell elements and retain the analytical rigor within the element. This methodology provides a powerful and robust computation scheme that maintains the computational efficiency of shell element solutions. The shell-intersection element was then applied to the cylinder-sphere and cylinder-cylinder intersection problems

  5. Elemental analysis of bottom ash from municipal incinerator by neutron activation analysis

    International Nuclear Information System (INIS)

    Kim, S. H.; Jang, S. H.; Moon, J. H.; Jung, Y. S.; Kim, Y. J.

    2003-01-01

    Elemental analysis of bottom ash generated from municipal solid waste incinerator was performed by neutron activation analysis. For this study, ash samples monthly collected from incinerator in D city were sieved with 5 mm mesh size, dried, pulverized by agate mortar and finally re-sieved with 200μ mesh size. Prepared samples were irradiated by neutrons using NAA No.1 irradiation hole in Korea Atomic Energy Research Institute. Activated samples were measured by gamma-ray spectrometer according to the relevant nuclear properties of target nuclides and the concentration of 33 elements were determined from the collected ash samples. Quality control was conducted by comparative analysis with two NIST standard reference materials simultaneously. Mean values and standard deviations of hazardous elements such as As, Cr, Cu, Fe, Mn, Sb and Zn among the determined elements were 3.8±6.9mg/kg, 620±0.12 %, 4.76±0.37 %, 0.26±0.10 %, 115±29 mg/kg and 0.71±0.19 %, respectively

  6. Finite Element Analysis of Patella Alta: A Patellofemoral Instability Model.

    Science.gov (United States)

    Watson, Nicole A; Duchman, Kyle R; Grosland, Nicole M; Bollier, Matthew J

    2017-01-01

    This study aims to provide biomechanical data on the effect of patella height in the setting of medial patellofemoral ligament (MPFL) reconstruction using finite element analysis. The study will also examine patellofemoral joint biomechanics using variable femoral insertion sites for MPFL reconstruction. A previously validated finite element knee model was modified to study patella alta and baja by translating the patella a given distance to achieve each patella height ratio. Additionally, the models were modified to study various femoral insertion sites of the MPFL (anatomic, anterior, proximal, and distal) for each patella height model, resulting in 32 unique scenarios available for investigation. In the setting of patella alta, the patellofemoral contact area decreased, resulting in a subsequent increase in maximum patellofemoral contact pressures as compared to the scenarios with normal patellar height. Additionally, patella alta resulted in decreased lateral restraining forces in the native knee scenario as well as following MPFL reconstruction. Changing femoral insertion sites had a variable effect on patellofemoral contact pressures; however, distal and anterior femoral tunnel malpositioning in the setting of patella alta resulted in grossly elevated maximum patellofemoral contact pressures as compared to other scenarios. Patella alta after MPFL reconstruction results in decreased lateral restraining forces and patellofemoral contact area and increased maximum patellofemoral contact pressures. When the femoral MPFL tunnel is malpositioned anteriorly or distally on the femur, the maximum patellofemoral contact pressures increase with severity of patella alta. When evaluating patients with patellofemoral instability, it is important to recognize patella alta as a potential aggravating factor. Failure to address patella alta in the setting of MPFL femoral tunnel malposition may result in even further increases in patellofemoral contact pressures, making it

  7. Nitinol Embolic Protection Filters: Design Investigation by Finite Element Analysis

    Science.gov (United States)

    Conti, Michele; de Beule, Matthieu; Mortier, Peter; van Loo, Denis; Verdonck, Pascal; Vermassen, Frank; Segers, Patrick; Auricchio, Ferdinando; Verhegghe, Benedict

    2009-08-01

    The widespread acceptance of carotid artery stenting (CAS) to treat carotid artery stenosis and its effectiveness compared with surgical counterpart, carotid endarterectomy (CEA), is still a matter of debate. Transient or permanent neurological deficits may develop in patients undergoing CAS due to distal embolization or hemodynamic changes. Design, development, and usage of embolic protection devices (EPDs), such as embolic protection filters, appear to have a significant impact on the success of CAS. Unfortunately, some drawbacks, such as filtering failure, inability to cross tortuous high-grade stenoses, malpositioning and vessel injury, still remain and require design improvement. Currently, many different designs of such devices are available on the rapidly growing dedicated market. In spite of such a growing commercial interest, there is a significant need for design tools as well as for careful engineering investigations and design analyses of such nitinol devices. The present study aims to investigate the embolic protection filter design by finite element analysis. We first developed a parametrical computer-aided design model of an embolic filter based on micro-CT scans of the Angioguard™ XP (Cordis Endovascular, FL) EPD by means of the open source pyFormex software. Subsequently, we used the finite element method to simulate the deployment of the nitinol filter as it exits the delivery sheath. Comparison of the simulations with micro-CT images of the real device exiting the catheter showed excellent correspondence with our simulations. Finally, we evaluated circumferential basket-vessel wall apposition of a 4 mm size filter in a straight vessel of different sizes and shape. We conclude that the proposed methodology offers a useful tool to evaluate and to compare current or new designs of EPDs. Further simulations will investigate vessel wall apposition in a realistic tortuous anatomy.

  8. Hydrothermal analysis in engineering using control volume finite element method

    CERN Document Server

    Sheikholeslami, Mohsen

    2015-01-01

    Control volume finite element methods (CVFEM) bridge the gap between finite difference and finite element methods, using the advantages of both methods for simulation of multi-physics problems in complex geometries. In Hydrothermal Analysis in Engineering Using Control Volume Finite Element Method, CVFEM is covered in detail and applied to key areas of thermal engineering. Examples, exercises, and extensive references are used to show the use of the technique to model key engineering problems such as heat transfer in nanofluids (to enhance performance and compactness of energy systems),

  9. Element analysis of Japanese traditional papers by PIXE method

    International Nuclear Information System (INIS)

    Suzuki, Tatsuya; Yasuda, Keisuke; Tani, Teruhiro

    2000-01-01

    The Japanese papers, 'washi', are made from the bast fibers of the plants. Since washi have the informations of the raw material plants, there is potentiality of the identification of the production place by the element analysis of the washi. Three kinds of washi made of kozo, which have different habitats, were prepared. The elements in their washi were measured by the PIXE. It was confirmed that the amount of elements included in the washi depend on the habitats of their raw material plants. (author)

  10. High accuracy 3D electromagnetic finite element analysis

    International Nuclear Information System (INIS)

    Nelson, E.M.

    1997-01-01

    A high accuracy 3D electromagnetic finite element field solver employing quadratic hexahedral elements and quadratic mixed-order one-form basis functions will be described. The solver is based on an object-oriented C++ class library. Test cases demonstrate that frequency errors less than 10 ppm can be achieved using modest workstations, and that the solutions have no contamination from spurious modes. The role of differential geometry and geometrical physics in finite element analysis will also be discussed. copyright 1997 American Institute of Physics

  11. Nonlinear nonstationary analysis with the finite element method

    International Nuclear Information System (INIS)

    Vaz, L.E.

    1981-01-01

    In this paper, after some introductory remarks on numerical methods for the integration of initial value problems, the applicability of the finite element method for transient diffusion analysis as well as dynamic and inelastic analysis is discussed, and some examples are presented. (RW) [de

  12. a finite element model for the analysis of bridge decks

    African Journals Online (AJOL)

    Dr Obe

    A FINITE ELEMENT MODEL FOR THE ANALYSIS OF BRIDGE DECKS. NIGERIAN JOURNAL OF TECHNOLOGY, VOL. 27 NO.1, MARCH 2008. 59. (a) Beam-plate system. (b) T-beam structural model. Fig. 1 Beam-plate structure idealisations. The matrix displacement method of analysis is used. The continuum structure is.

  13. PIXE analysis of trace elements in cetacean teeth

    International Nuclear Information System (INIS)

    Mitani, Yoko; Arai, Nobuaki; Sakamoto, Wataru; Yoshida, Koji

    1997-01-01

    PIXE was adopted for analysis of trace elements in teeth of two species of cetaceans, sperm whale (Physeter microcephalus) and pantropical spotted dolphin (Stenella attenuata). The analyses were performed along with the growth layer of the teeth, which is formed annually, suitable for age determination. Mn, Fe, Cu, Zu and Sr were detected in the teeth of sperm whale and pantropical spotted dolphin. Among these trace elements, gradual increase was observed for Zn/Ca ratio in the sperm whale's teeth. (author)

  14. Trace elements in coloured opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Smallwood, A.

    1995-01-01

    Neutron activation analysis was used to determine the concentration of trace elements in 50 samples of orange, yellow, honey, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were evaluated to determine the relationship between trace elements content and opal colour. (author). 10 refs., 10 figs., 3 tabs

  15. Elemental Study in Soybean and Products by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Vorapot, Permnamtip; Arporn Busamongkol; Sirinart, Laoharojanaphand

    2009-07-01

    Full text: Elements were analyzed in soybean and products by Instrumental Neutron Activation Analysis (INAA), Pseudo-Cyclic Instrumental Neutron Activation Analysis (PCINAA) and Epithermal Instrumental Neutron Activation Analysis (EINAA). Elements detected in sample were include Al, Br, Ca, Cl, Cu, Fe, I, K, Mg, Mn Na, Se and Zn. The result showed that the nutritional contents changed after food processing. From experiments (n = 2), it was found that after food processing, the concentration of Cl and Na in soy bean curd increased from 0.0045 and 0.0011% to found 0.91 and 0.39 %, respectively. Other elements did not differ from soybean. Limits of detection for Al, Br, Ca, Cl, Cu, Fe, I, K, Mg, Mn Na, Se and Zn were 0.05, 0.2, 50, 6, 10, 15, 0.05, 30, 40, 5, 5, 0.05 and 1 mg.kg - 1, respectively

  16. Analysis of Brick Masonry Wall using Applied Element Method

    Science.gov (United States)

    Lincy Christy, D.; Madhavan Pillai, T. M.; Nagarajan, Praveen

    2018-03-01

    The Applied Element Method (AEM) is a versatile tool for structural analysis. Analysis is done by discretising the structure as in the case of Finite Element Method (FEM). In AEM, elements are connected by a set of normal and shear springs instead of nodes. AEM is extensively used for the analysis of brittle materials. Brick masonry wall can be effectively analyzed in the frame of AEM. The composite nature of masonry wall can be easily modelled using springs. The brick springs and mortar springs are assumed to be connected in series. The brick masonry wall is analyzed and failure load is determined for different loading cases. The results were used to find the best aspect ratio of brick to strengthen brick masonry wall.

  17. Ring-element analysis of layered orthotropic bodies

    DEFF Research Database (Denmark)

    Jørgensen, O.

    1993-01-01

    For the analysis of arbitrarily laminated circular bodies, a displacement-based ring-element is presented. The analysis is performed in a cylindrical coordinate system. The method of analysis requires the boundary conditions as well as the external forces to be pi-periodic. The element formulation...... accounts for a desired degree of approximation of the displacement field in the direction of the circumference. This is done by a truncated Fourier expansion of the angular dependence of the displacements in terms of trigonometric functions. Thus the Fourier expansion coefficients are the unknowns...... to that of solutions obtained by traditional 3D elements. A scheme for analytical integration of the angular dependence of the stiffness matrix is given....

  18. Radiochemical neutron activation analysis for trace elements of basic ingredients of pan

    International Nuclear Information System (INIS)

    Zaidi, J.H.; Arif, M.; Fatima, I; Qureshi, I.H.

    2002-01-01

    Extensive use of pan, by one-tenth of world's population, entails the evaluation of trace element contents in its ingredients. Radiochemical neutron activation analysis (RNAA) was developed and successfully employed to determine the concentration of 36 trace elements (essential, toxic and nonessential) in its four basic ingredients, leaf of betel pepper, betel nut, catechu and lime. The radiochemical separation methodology has significantly improved the detection limits of most of these elements due to suppression of Compton background. Base-line values of certain toxic and essential elements in these ingredients is provided. The daily intake of essential and toxic elements through pan was estimated and compared with the recommended values. The cumulative intake of Mn is four times higher than the recommended value and that of toxic elements is well below the tolerance limits. (author)

  19. Static Analysis of Steel Fiber Concrete Beam With Heterosis Finite Elements

    Directory of Open Access Journals (Sweden)

    James H. Haido

    2014-08-01

    Full Text Available Steel fiber is considered as the most commonly used constructional fibers in concrete structures. The formulation of new nonlinearities to predict the static performance of steel fiber concrete composite structures is considered essential. Present study is devoted to investigate the efficiency of utilizing heterosis finite elements analysis in static analysis of steel fibrous beams. New and simple material nonlinearities are proposed and used in the formulation of these elements. A computer program coded in FORTRAN was developed to perform current finite element static analysis with considering four cases of elements stiffness matrix determination. The results are compared with the experimental data available in literature in terms of central deflections, strains, and failure form, good agreement was found. Suitable outcomes have been observed in present static analysis with using of tangential stiffness matrix and stiffness matrix in second iteration of the load increment.

  20. Finite Element Analysis and Design of Experiments in Engineering Design

    OpenAIRE

    Eriksson, Martin

    1999-01-01

    Projects with the objective of introducing Finite Element Analysis (FEA) into the early phases of the design process have previously been carried out at the Department of Machine Design, see e.g. the Doctoral thesis by Burman [13]. These works clearly highlight the usefulness of introducing design analysis early in the design process. According to Bjärnemo and Burman [10] the most significant advantage of applying design analysis early in the design process was the shift from verification to ...

  1. Determination of mutually interfering elements in activation analysis

    International Nuclear Information System (INIS)

    Figueiredo, A.M.G.

    1979-01-01

    The determination of the elements present in the groups scandium-zinc, mercury-selenium and arsenic-antimony-bromine represents a classical problem in thermal neutron activation analysis because the gamma-ray peaks of the radioisotopes produced from these elements by activation appear very close in the spectrum. A study is made of the possibility of simultaneous instrumental determination of these elements by means of the spectrum stripping technique, using a 400-channel analyser coupled to a Nal(Tl) detector and a 4096-channel analyser coupled to a Ge(Li) detector. Artificial mixtures of the interfering elements in varying proportions are prepared, so as to reproduce possible real samples, where the elements may be present at several concentrations. Radiochemical separation techniques for the cited elements are studied with the use of tracers. For the separation of scadium and zinc, the technique of extraction chromatography is applied. The separation of mercury and selenium is accomplished by means of ion exchange. The technique of coprecipitation is used to separate bromine from arsenic and antimony followed by ion exchange to isolate these two elements from each other. The precision and the accuracy of the results are discussed. (Author) [pt

  2. Chemical analysis of useful trace elements in sea water

    International Nuclear Information System (INIS)

    Katoh, Shunsaku; Fujii, Ayako; Miyai, Yoshitaka; Sakane, Kohji; Ogata, Noboru.

    1983-01-01

    The methods for the analysis of useful trace elements in sea water which have been tried so far are reviewed, and these methods are described briefly from the standpoint of studying the collection of resources. Ag and Au can be determined by concentrating sea water by ion-exchange method, solvent extraction method and electrodeposition method, then the elements are measured quantitatively by activation analysis and atomic absorption spectrochemical analysis. Sr, B and Li, which exist in relatively high concentration in sea water, are determined easily by atomic absorption spectrochemical analysis and absorption spectrometry. U, Mo and V are measured suitably by concentrating the elements by coprecipitation or solvent extraction method, and measuring by fluorescence analysis and arsenazo-3 method for U and through graphite-atomic absorption analysis for Mo and V. It has been revealed that the concentration of Ag and Au in sea water is extremely low, accordingly the recovery study is not conducted recently. On the other hand, the adsorption method using hydrated titanium oxide and amidoxim adsorbents for U, Mo and V, the adsorption method using aluminum adsorbent for Li, and the adsorption method using magnesium oxide and zirconium hydroxide and the solvent extraction method for B are hopeful to recover these elements. (Yoshitake, I.)

  3. Ir and Rare Earth's Elements determination by Neutron Activation Analysis and ICP - MS in soil samples

    Science.gov (United States)

    Salvini, A.; Cattadori, C.; Broggini, C.; Cagnazzo, M.; Ori, Gian Gabriele; Nisi, S.; Borio, A.; Manera, S.

    2006-05-01

    The platinum metals depleted in the earth's crust are relative to their cosmic abundance; concentration of these elements in sediments may thus indicate influxes of extraterrestrial material. Analysis of these parameters are done easily by Neutron Activation Analysis (NAA) and comparative results with ICP-MS technique show a good match. Results, adjust parameters and limits of this method will be displayed in tables.

  4. Correlation analysis of trace elemental data obtained from blood sera of ovarian cancer patients using PIXE

    International Nuclear Information System (INIS)

    Naidu, B.G.; Sarita, P.; Naga Raju, G.J.

    2017-01-01

    Proton induced X-ray emission (PIXE) technique is used for analysis of trace elements present in the blood sera of ovarian cancer patients and healthy controls. This work is also intended to establish the role played by trace elements in carcinogenic process. It is observed that the concentrations of elements Ti, V, Cr, Mn, Fe, Ni, Rb and Sr are lower and the concentration of Cu is higher in the cancer patients when compared to controls. However, no change in concentration is found in the elements Co, Zn, As, Se and Br. Correlation analysis of the data using SPSS 16.0 has revealed a strong positive correlation between Ti-V, Ni-Co, Cu-Fe, As-Ti, Br-Ti, Br-V and Sr-Fe while strong negative correlations are observed for Cu-Ti, As-Cu and Br-Cu. Changes in trace elemental content are probably associated with ovarian carcinogenesis. (author)

  5. PIXE trace element analysis of a selection of wines

    International Nuclear Information System (INIS)

    Houdayer, A.; Hinrichsen, P.F.; Martin, J.P.; Belhadfa, A.

    1987-01-01

    The University of Montreal EN Tandem accelerator and a Si (Li) X-ray detector were used for a PIXE (Proton Induced X-ray emission) trace element analysis of a selection of wines. Quantitative measurements of the concentrations of the sixteen trace elements Na, Mg, Al, Si, P, S, Cl, K, Ca, Cr, Mn, Fe, Co, Cu, Zn, and Br were made. To optimize the sensitivity, spectra were recorded at 1.0 MeV proton energy for elements with Z 19. The absolute concentrations of the trace elements were determined by doping the samples of wine with 1000 ppm of vanadium for the 1.0 MeV bombardments, and 1000 ppm of yttrium for the 3.0 MeV irradiations. The targets were prepared by depositing a few microliters of the wine onto a Nuclepore filter

  6. Finite element analysis of rotating beams physics based interpolation

    CERN Document Server

    Ganguli, Ranjan

    2017-01-01

    This book addresses the solution of rotating beam free-vibration problems using the finite element method. It provides an introduction to the governing equation of a rotating beam, before outlining the solution procedures using Rayleigh-Ritz, Galerkin and finite element methods. The possibility of improving the convergence of finite element methods through a judicious selection of interpolation functions, which are closer to the problem physics, is also addressed. The book offers a valuable guide for students and researchers working on rotating beam problems – important engineering structures used in helicopter rotors, wind turbines, gas turbines, steam turbines and propellers – and their applications. It can also be used as a textbook for specialized graduate and professional courses on advanced applications of finite element analysis.

  7. TAPIR, Thermal Analysis of HTGR with Graphite Sleeve Fuel Elements

    International Nuclear Information System (INIS)

    Weicht, U.; Mueller, W.

    1983-01-01

    1 - Nature of the physical problem solved: Thermal analysis of a reactor core containing internally and/or externally gas cooled prismatic fuel elements of various geometries, rating, power distribution, and material properties. 2 - Method of solution: A fuel element in this programme is regarded as a sector of a fuelled annulus with graphite sleeves of any shape on either side and optional annular gaps between fuel and graphite and/or within the graphite. It may have any centre angle and the fuelled annulus may become a solid cylindrical rod. Heat generation in the fuel is assumed to be uniform over the cross section and peripheral heat flux into adjacent sectors is ignored. Fuel elements and coolant channels are treated separately, then linked together to fit a specified pattern. 3 - Restrictions on the complexity of the problem: Maxima of: 50 fuel elements; 50 cooled channels; 25 fuel geometries; 25 coolant channel geometries; 10 axial power distributions; 10 graphite conductivities

  8. Biomonitoring of air pollution through trace element analysis

    International Nuclear Information System (INIS)

    Bamford, S.A.; Osae, E.K.; Aboh, I.J.; Serfor-Armah, Y.; Nyarko, B.; Odamtten, G.T.

    1999-01-01

    Studies are being carried out to determine the potential and reliability in the use of local lichen species for biomonitoring air pollution in Ghana. The location of most of the gold mines in forest areas of the country presents the gold mining industry as a suitable setting for such investigations. The nuclear-related techniques being used in the multielement analysis of lichen samples and air filter samples are instrumental neutron activation analysis (Miniature Neutron Source Reactor) and energy dispersive x-ray fluorescence analysis (tube-excitation). Validation of the quantitative methods of the INAA through analysis of standard and certified reference materials of orchard leaves NBS SRM 1571 and BCR-CRM No. 279 gave very good results for most elements analyzed. Elemental analysis of identified lichen samples will be done beating in mind microclimatic factors, specie type and nature of soil. (author)

  9. Biomonitoring of air pollution through trace element analysis

    International Nuclear Information System (INIS)

    Bamford, S.A.; Osae, E.K.; Aboh, I. J.; Serfor-Armah, Y.; Nyarko, B.; Ofosu, F.; Odamtten, G.T.

    1999-04-01

    Studies are being carried out to determine the potential and reliability in the use of local lichen species for biomonitoring air pollution in Ghana. The location of most of the gold mines in forest areas of the country presents the gold mining industry as a suitable setting for such investigations. The nuclear-related techniques being used in the multielement analysis of lichen samples and air filter samples are instrumental neutron activation analysis (Miniature Neutron Source Reactor) and energy dispersive x-ray fluorescence analysis (tube-excitation). Validation of the quantitative methods of the INAA through analysis of standard certified reference materials of orchard leaves NBS SRM 1571 and BCR-CRM No. 279 gave very good results for most elements analyzed. Elemental analysis of identified lichen samples will be done bearing in mind microclimatic factors, specie type and nature of soil. (author)

  10. Elemental analysis of cotton by laser-induced breakdown spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Schenk, Emily R.; Almirall, Jose R.

    2010-05-01

    Laser-induced breakdown spectroscopy (LIBS) has been applied to the elemental characterization of unprocessed cotton. This research is important in forensic and fraud detection applications to establish an elemental fingerprint of U.S. cotton by region, which can be used to determine the source of the cotton. To the best of our knowledge, this is the first report of a LIBS method for the elemental analysis of cotton. The experimental setup consists of a Nd:YAG laser that operates at the fundamental wavelength as the LIBS excitation source and an echelle spectrometer equipped with an intensified CCD camera. The relative concentrations of elements Al, Ba, Ca, Cr, Cu, Fe, Mg, and Sr from both nutrients and environmental contributions were determined by LIBS. Principal component analysis was used to visualize the differences between cotton samples based on the elemental composition by region in the U.S. Linear discriminant analysis of the LIBS data resulted in the correct classification of >97% of the cotton samples by U.S. region and >81% correct classification by state of origin.

  11. Finite element analysis of FRP-strengthened RC beams

    Directory of Open Access Journals (Sweden)

    Teeraphot Supaviriyakit

    2004-05-01

    Full Text Available This paper presents a non-linear finite element analysis of reinforced concrete beam strengthened with externally bonded FRP plates. The finite element modeling of FRP-strengthened beams is demonstrated. Concrete and reinforcing bars are modeled together as 8-node isoparametric 2D RC element. The FRP plate is modeled as 8-node isoparametric 2D elastic element. The glue is modeled as perfect compatibility by directly connecting the nodes of FRP with those of concrete since there is no failure at the glue layer. The key to the analysis is the correct material models of concrete, steel and FRP. Cracks and steel bars are modeled as smeared over the entire element. Stress-strain properties of cracked concrete consist of tensile stress model normal to crack, compressive stress model parallel to crack and shear stress model tangential to crack. Stressstrain property of reinforcement is assumed to be elastic-hardening to account for the bond between concrete and steel bars. FRP is modeled as elastic-brittle material. From the analysis, it is found that FEM can predict the load-displacement relation, ultimate load and failure mode of the beam correctly. It can also capture the cracking process for both shear-flexural peeling and end peeling modes similar to the experiment.

  12. Three dimensional finite element linear analysis of reinforced concrete structures

    International Nuclear Information System (INIS)

    Inbasakaran, M.; Pandarinathan, V.G.; Krishnamoorthy, C.S.

    1979-01-01

    A twenty noded isoparametric reinforced concrete solid element for the three dimensional linear elastic stress analysis of reinforced concrete structures is presented. The reinforcement is directly included as an integral part of the element thus facilitating discretization of the structure independent of the orientation of reinforcement. Concrete stiffness is evaluated by taking 3 x 3 x 3 Gauss integration rule and steel stiffness is evaluated numerically by considering three Gaussian points along the length of reinforcement. The numerical integration for steel stiffness necessiates the conversion of global coordiantes of the Gaussian points to nondimensional local coordinates and this is done by Newton Raphson iterative method. Subroutines for the above formulation have been developed and added to SAP and STAP routines for solving the examples. The validity of the reinforced concrete element is verified by comparison of results from finite element analysis and analytical results. It is concluded that this finite element model provides a valuable analytical tool for the three dimensional elastic stress analysis of concrete structures like beams curved in plan and nuclear containment vessels. (orig.)

  13. Qualitative PIXE analysis of mineral elements in some phytopharmaceutic drugs

    International Nuclear Information System (INIS)

    Preoteasa, E.A.; Harangus, Livia; Gugiu, M; Iordan, Andreea; Ciortea, C.

    2002-01-01

    A large number of phytopharmaceutic drugs are being developed, due to positive effects in various diseases and to high tolerance by the organism. While their medicinally active compounds have been identified, little attention has been paid to their mineral micro- and trace elements. The mineral elements in the drug may have therapeutic or toxic effects which should be properly assessed. Nuclear and atomic methods allow sensitive multielement detection and we previously performed nuclear activation analysis of some Romanian drugs made by plants. Despite this method's high sensitivity, its use is limited by the availability of a nuclear reactor. Particle-induced X-ray emission (PIXE) provides an alternative, and here we examined its potential for the analysis of mineral elements in three commercial phytopharmaceutical preparations, namely, Liv52, Mentat, and Geriforte. The PIXE measurements were performed with 3 MeV protons at the 8.5 MV NIPNE-HH tandem accelerator, using a hyper pure Ge detector, normally oriented and connected to a multichannel analyzer and to a computer; the drug pills were fixed at 45 angle with respect to the beam. In all drugs PIXE detected mineral elements with Z > 16 down to trace levels. Major elements included K, Ca, Fe, Cu, and Zn, and minor/trace amounts of S, Cl, Ti, Cr, Mn, Ni, Ga, Br, Rb, Sr, Hg, and As/Pb were detected. Some differences were seen between the three drugs. Although at trace levels Ga, As, Hg and Pb are not toxic, one should consider that their accumulation might be harmful and caution seems recommendable on long-term cure. Most of the other elements are known to exert a positive biological role, and both in major and trace levels they may contribute to the therapeutic action. Thus PIXE analysis of mineral elements in phytopharmaceutic drugs, even qualitative, is useful for evaluating the benefits and risks in the therapy. (authors)

  14. Finite element analysis of degraded concrete structures - Workshop proceedings

    International Nuclear Information System (INIS)

    1999-09-01

    This workshop is related to the finite element analysis of degraded concrete structures. It is composed of three sessions. The first session (which title is: the use of finite element analysis in safety assessments) comprises six papers which titles are: Historical Development of Concrete Finite Element Modeling for Safety Evaluation of Accident-Challenged and Aging Concrete Structures; Experience with Finite Element Methods for Safety Assessments in Switzerland; Stress State Analysis of the Ignalina NPP Confinement System; Prestressed Containment: Behaviour when Concrete Cracking is Modelled; Application of FEA for Design and Support of NPP Containment in Russia; Verification Problems of Nuclear Installations Safety Software of Strength Analysis (NISS SA). The second session (title: concrete containment structures under accident loads) comprises seven papers which titles are: Two Application Examples of Concrete Containment Structures under Accident Load Conditions Using Finite Element Analysis; What Kind of Prediction for Leak rates for Nuclear Power Plant Containments in Accidental Conditions; Influence of Different Hypotheses Used in Numerical Models for Concrete At Elevated Temperatures on the Predicted Behaviour of NPP Core Catchers Under Severe Accident Conditions; Observations on the Constitutive Modeling of Concrete Under Multi-Axial States at Elevated Temperatures; Analyses of a Reinforced Concrete Containment with Liner Corrosion Damage; Program of Containment Concrete Control During Operation for the Temelin Nuclear Power Plant; Static Limit Load of a Deteriorated Hyperbolic Cooling Tower. The third session (concrete structures under extreme environmental load) comprised five papers which titles are: Shear Transfer Mechanism of RC Plates After Cracking; Seismic Back Calculation of an Auxiliary Building of the Nuclear Power Plant Muehleberg, Switzerland; Seismic Behaviour of Slightly Reinforced Shear Wall Structures; FE Analysis of Degraded Concrete

  15. Neutron activation analysis for bulk and trace elements in urine

    International Nuclear Information System (INIS)

    Cornelis, R.; Speecke, A.; Hoste, J.

    1975-01-01

    Problems in sampling urine for trace element analysis by neutron activation are systematically examined. Collection, storage, sample preparation and contamination hazards during irradiation are studied in detail. Three different sizes of urine samples are prepared for analysis, depending on the concentration and nuclear properties of the elements, and suitable multielement doped urine standards are used. As, Br, Ca, Cl, Co, Cr, Cs, Cu, Hg, I, K, Mg, Mn, Na, Rb, Se and Zn are determined. The extreme care given to sample collection, use of ''ultra-clean'' vials, and work in a dust-free room allows consistent values to be obtained over long periods of time. A literature review of the amounts of forty elements present in urine per day is also given

  16. Adaptive finite-element ballooning analysis of bipolar ionized fields

    International Nuclear Information System (INIS)

    Al-Hamouz, Z.M.

    1995-01-01

    This paper presents an adaptive finite-element iterative method for the analysis of the ionized field around high-voltage bipolar direct-current (HVDC) transmission line conductors without resort to Deutsch's assumption. A new iterative finite-element ballooning technique is proposed to solve Poisson's equation wherein the commonly used artificial boundary around the transmission line conductors is simulated at infinity. Unlike all attempts reported in the literature for the solution of ionized field, the constancy of the conductors' surface field at the corona onset value is directly implemented in the finite-element formulation. In order to investigate the effectiveness of the proposed method, a laboratory model was built. It has been found that the calculated V-I characteristics and the ground-plane current density agreed well with those measured experimentally. The simplicity in computer programming in addition to the low number of iterations required to achieve convergence characterize this method of analysis

  17. Contribution to the analysis of light elements using x fluorescence excited by radio-elements

    International Nuclear Information System (INIS)

    Robert, A.

    1964-01-01

    In order to study the possibilities of using radioactive sources for the X-fluorescence analysis of light elements, the principle is given, after a brief description of X-fluorescence, of the excitation of this phenomenon by X, β and α emission from radio-elements. The operation and use of the proportional gas counter for X-ray detection is described. A device has been studied for analysing the elements of the 2. and 3. periods of the Mendeleev table. It makes it possible to excite the fluorescence with a radioactive source emitting X-rays or a particles; the X-ray fluorescence penetrates into a window-less proportional counter, this being made possible by the use of an auxiliary electric field in the neighbourhood of the sample. The gas detection pressure leading to the maximum detection yield is given. The spectra are given for the K α lines of 3. period elements excited by 55 Fe, 3 H/Zr and 210 Po sources; for the 2. period the K α spectra of carbon and of fluorine excited by the α particles of 210 Po. (author) [fr

  18. Instrumental methods for analysis of some elements in flour

    International Nuclear Information System (INIS)

    Zagrodzki, P.; Dutkiewicz, E.M.; Malec, P.; Krosniak, M.; Knap, W.

    1993-10-01

    For ten various brands of flour contents of chosen (heavy) elements were determined by means of ICP, GF-AAS, PIXE and ASV/CSV methods. General performance of participating laboratories as well as pros and cons of different analytical methods were compared and discussed. (author). 6 refs, 6 figs, 7 tabs

  19. Nonlinear Finite Element Analysis of Pull-Out Test

    DEFF Research Database (Denmark)

    Saabye Ottesen, N

    1981-01-01

    A specific pull-out test used to determine in-situ concrete compressive strength is analyzed. This test consists of a steel disc that is extracted from the structure. The finite element analysis considers cracking as well as strain hardening and softening in the pre- and post-failure region...

  20. Trace element analysis of archaeological artefacts from Pella, Jordan

    International Nuclear Information System (INIS)

    Clayton, E.

    1985-01-01

    A brief history of the site at Pella, Jordan is presented, as a prelude to an analysis of the element composition of 82 pottery sherds. Statistical results from this data support the archaeological evidence for occupation during the Late Bronze and Early Iron Age

  1. Multivariate statistical analysis of major and trace element data for ...

    African Journals Online (AJOL)

    Multivariate statistical analysis of major and trace element data for niobium exploration in the peralkaline granites of the anorogenic ring-complex province of Nigeria. PO Ogunleye, EC Ike, I Garba. Abstract. No Abstract Available Journal of Mining and Geology Vol.40(2) 2004: 107-117. Full Text: EMAIL FULL TEXT EMAIL ...

  2. Microlocal methods in the analysis of the boundary element method

    DEFF Research Database (Denmark)

    Pedersen, Michael

    1993-01-01

    The application of the boundary element method in numerical analysis is based upon the use of boundary integral operators stemming from multiple layer potentials. The regularity properties of these operators are vital in the development of boundary integral equations and error estimates. We show...

  3. Analysis of Trace Elements in South African Clinkers using Latent ...

    African Journals Online (AJOL)

    The trace element content of clinkers (and possibly of cements) can be used to identify the manufacturing factory. The Mg, Sr, Ba, Mn, Ti, Zr, Zn and V content of clinkers give detailed information for the determination of the origin of clinkers produced in different factories. However, for the analysis of such complex data there ...

  4. GRIZ: Visualization of finite element analysis results on unstructured grids

    International Nuclear Information System (INIS)

    Dovey, D.; Loomis, M.D.

    1994-01-01

    GRIZ is a general-purpose post-processing application that supports interactive visualization of finite element analysis results on three-dimensional unstructured grids. GRIZ includes direct-to-videodisc animation capabilities and is being used as a production tool for creating engineering animations

  5. Advanced chemical analysis service for elements, radionuclides and phases

    International Nuclear Information System (INIS)

    Sansoni, B.

    1986-01-01

    A review is given on the structure, organisation and performance of the chemical analysis service of the Central Department for Chemical Analysis at the Kernforschungsanlage Juelich GmbH. The research and development programs together with the infrastructure of the Centre afford to analyse almost all stable elements of the periodical table in almost any material. The corresponding chemical analysis service has been organized according to a new modular system of analytical steps. According to this, the most complicated and, therefore, most general case of an analytical scheme for element and radionuclide analysis in any type of material can be differentiated into about 14 different steps, the modules. They are more or less independent of the special problem. The laboratory is designed and organized according to these steps. (orig./PW) [de

  6. Elemental composition of platelets. Part I. Sampling and sample preparation of platelets for trace-element analysis

    International Nuclear Information System (INIS)

    Iyengar, G.V.; Borberg, H.; Kasperek, K.; Kiem, J.; Siegers, M.; Feinendegen, L.E.; Gross, R.

    1979-01-01

    Sampling of platelets for trace-element analysis poses special problems: obtaining adequate sample materials, achieving a sufficient cell purity, preserving viability (integrity), correcting for trapped plasma, and controlling contamination. We used a blood-cell separator for the primary isolation of platelets from blood, and differential centrifugation in natural plasma to further isolate them. The pyrimidopyrimidine RA233 was used as a stabilizer to maintain viability. 131 I-labeled human serum albumin was used to estimate trapped plasma. Contamination was controlled by using five-times-distilled water to simulate donor's blood in the system and by comparing three fractions: the serum, the first portion of the platelet-rich plasma, and the supernatant plasma after the final centrifugation. Neutron activation analysis was used for the elemental analysis. A single differential centrifugation of the platelet-rich plasma from the blood-cell separator at 400 x g for 8 min was optimum (mean mass fractions: erythrocytes/platelets < 5 mg/g and leukocytes/platelets < 20 mg/g). The trapped plasma in the wet platelet samples amounted to about 0.40 g/g. No appreciable contamination from the sampling system was found for the elements Ag, Cd, Co, Cr, Cs, Cu, Fe, Mo, Rb, Sb, Se, and Zn. 2 figures, 3 tables

  7. Developments in Dynamic Analysis for quantitative PIXE true elemental imaging

    International Nuclear Information System (INIS)

    Ryan, C.G.

    2001-01-01

    Dynamic Analysis (DA) is a method for projecting quantitative major and trace element images from PIXE event data-streams (off-line or on-line) obtained using the Nuclear Microprobe. The method separates full elemental spectral signatures to produce images that strongly reject artifacts due to overlapping elements, detector effects (such as escape peaks and tailing) and background. The images are also quantitative, stored in ppm-charge units, enabling images to be directly interrogated for the concentrations of all elements in areas of the images. Recent advances in the method include the correction for changing X-ray yields due to varying sample compositions across the image area and the construction of statistical variance images. The resulting accuracy of major element concentrations extracted directly from these images is better than 3% relative as determined from comparisons with electron microprobe point analysis. These results are complemented by error estimates derived from the variance images together with detection limits. This paper provides an update of research on these issues, introduces new software designed to make DA more accessible, and illustrates the application of the method to selected geological problems.

  8. A comparative phylogenetic analysis of full-length mariner elements ...

    Indian Academy of Sciences (India)

    Unknown

    recent study showing non-occurance of inter-subfamily excisions because of .... length shown in our figure is greater because of the gaps introduced to maintain an ... to test the feasibility of transforming silkmoths with a foreign gene of ...

  9. A Comparative Analysis of Nutrients and Mineral Elements Content ...

    African Journals Online (AJOL)

    crude protein (Cp) ad crude fibre (Cf) content than A. gayanus. The high Cp .... protein. This gives an indication of relatively high quality of this grass species as livestock feed than its counterpart. Proteins play an important role in Carbon- dioxide fixation during .... Ruminant Nutrition, 1st edition, Macmillan Press. Ltd, London ...

  10. Biological reference materials and analysis of toxic elements

    Energy Technology Data Exchange (ETDEWEB)

    Subramanian, R; Sukumar, A

    1988-12-01

    Biological monitoring of toxic metal pollution in the environment requires quality control analysis with use of standard reference materials. A variety of biological tissues are increasingly used for analysis of element bioaccumulation, but the available Certified Reference Materials (CRMs) are insufficient. An attempt is made to review the studies made using biological reference materials for animal and human tissues. The need to have inter-laboratory studies and CRM in the field of biological monitoring of toxic metals is also discussed.

  11. Elemental analysis of brazing alloy samples by neutron activation technique

    International Nuclear Information System (INIS)

    Eissa, E.A.; Rofail, N.B.; Hassan, A.M.; El-Shershaby, A.; Walley El-Dine, N.

    1996-01-01

    Two brazing alloy samples (C P 2 and C P 3 ) have been investigated by Neutron activation analysis (NAA) technique in order to identify and estimate their constituent elements. The pneumatic irradiation rabbit system (PIRS), installed at the first egyptian research reactor (ETRR-1) was used for short-time irradiation (30 s) with a thermal neutron flux of 1.6 x 10 1 1 n/cm 2 /s in the reactor reflector, where the thermal to epithermal neutron flux ratio is 106. Long-time irradiation (48 hours) was performed at reactor core periphery with thermal neutron flux of 3.34 x 10 1 2 n/cm 2 /s, and thermal to epithermal neutron flux ratio of 79. Activation by epithermal neutrons was taken into account for the (1/v) and resonance neutron absorption in both methods. A hyper pure germanium detection system was used for gamma-ray acquisitions. The concentration values of Al, Cr, Fe, Co, Cu, Zn, Se, Ag and Sb were estimated as percentages of the sample weight and compared with reported values. 1 tab

  12. Elemental analysis of brazing alloy samples by neutron activation technique

    Energy Technology Data Exchange (ETDEWEB)

    Eissa, E A; Rofail, N B; Hassan, A M [Reactor and Neutron physics Department, Nuclear Research Centre, Atomic Energy Authority, Cairo (Egypt); El-Shershaby, A; Walley El-Dine, N [Physics Department, Faculty of Girls, Ain Shams Universty, Cairo (Egypt)

    1997-12-31

    Two brazing alloy samples (C P{sup 2} and C P{sup 3}) have been investigated by Neutron activation analysis (NAA) technique in order to identify and estimate their constituent elements. The pneumatic irradiation rabbit system (PIRS), installed at the first egyptian research reactor (ETRR-1) was used for short-time irradiation (30 s) with a thermal neutron flux of 1.6 x 10{sup 1}1 n/cm{sup 2}/s in the reactor reflector, where the thermal to epithermal neutron flux ratio is 106. Long-time irradiation (48 hours) was performed at reactor core periphery with thermal neutron flux of 3.34 x 10{sup 1}2 n/cm{sup 2}/s, and thermal to epithermal neutron flux ratio of 79. Activation by epithermal neutrons was taken into account for the (1/v) and resonance neutron absorption in both methods. A hyper pure germanium detection system was used for gamma-ray acquisitions. The concentration values of Al, Cr, Fe, Co, Cu, Zn, Se, Ag and Sb were estimated as percentages of the sample weight and compared with reported values. 1 tab.

  13. Analysis of gear reducer housing using the finite element method

    Science.gov (United States)

    Miklos, I. Zs; Miklos, C. C.; Alic, C. I.; Raţiu, S.

    2018-01-01

    The housing is an important component in the construction of gear reducers, having the role of fixing the relative position of the shafts and toothed wheels. At the same time, the housing takes over, via the bearings, the shaft loads resulting when the toothed wheel is engaging another toothed mechanism (i.e. power transmission through belts or chains), and conveys them to the foundation on which it is anchored. In this regard, in order to ensure the most accurate gearing, a high stiffness of the housing is required. In this paper, we present the computer-aided 3D modelling of the housing (in cast version) of a single stage cylindrical gear reducer, using the Autodesk Inventor Professional software, on the principle of constructive sizing. For the housing resistance calculation, we carried out an analysis using the Autodesk Simulation Mechanical software to apply the finite element method, based on the actual loads, as well as a comparative study of the stress and strain distribution, for several tightening values of the retaining bolts that secure the cover and the foundation housing.

  14. Piezoelectric Analysis of Saw Sensor Using Finite Element Method

    Directory of Open Access Journals (Sweden)

    Vladimír KUTIŠ

    2013-06-01

    Full Text Available In this contribution modeling and simulation of surface acoustic waves (SAW sensor using finite element method will be presented. SAW sensor is made from piezoelectric GaN layer and SiC substrate. Two different analysis types are investigated - modal and transient. Both analyses are only 2D. The goal of modal analysis, is to determine the eigenfrequency of SAW, which is used in following transient analysis. In transient analysis, wave propagation in SAW sensor is investigated. Both analyses were performed using FEM code ANSYS.

  15. A Comparative Study on Error Analysis

    DEFF Research Database (Denmark)

    Wu, Xiaoli; Zhang, Chun

    2015-01-01

    Title: A Comparative Study on Error Analysis Subtitle: - Belgian (L1) and Danish (L1) learners’ use of Chinese (L2) comparative sentences in written production Xiaoli Wu, Chun Zhang Abstract: Making errors is an inevitable and necessary part of learning. The collection, classification and analysis...... the occurrence of errors either in linguistic or pedagogical terms. The purpose of the current study is to demonstrate the theoretical and practical relevance of error analysis approach in CFL by investigating two cases - (1) Belgian (L1) learners’ use of Chinese (L2) comparative sentences in written production...... of errors in the written and spoken production of L2 learners has a long tradition in L2 pedagogy. Yet, in teaching and learning Chinese as a foreign language (CFL), only handful studies have been made either to define the ‘error’ in a pedagogically insightful way or to empirically investigate...

  16. Finite Element Analysis of Composite Aircraft Fuselage Frame

    Science.gov (United States)

    Dandekar, Aditya Milind

    Composites have been introduced in aircraft industries, for their stronger, stiffer, and lighter properties than their metal-alloys counterparts. The general purpose of an aircraft is to transport commercial or military payload. Aircraft frames primarily maintains the shape of fuselage and prevent instability of the structure. Fuselage is similar as wing in construction which consist of longitudinal elements (longerons and stringers), transverse elements (frames and bulkheads) and its external skin. The fuselage is subjected to forces such as the wing reactions, landing gear reaction, empennage reaction, inertia forces subjected due to size and weight, internal pressure forces due to high altitude. Frames also ensure fail-safe design against skin crack propagation due to hoops stress. Ideal fuselage frames cross section is often circular ring shape with a frame cap of Z section. They are mainly made up of light alloy commonly used is aluminium alloys such as Al-2024, Al-7010, Al-7050, Al-7175. Aluminium alloys have good strength to density ratios in compression and bending of thin plate. A high strength to weight ratio of composite materials can result in a lighter aircraft structure or better safety factor. This research focuses on analysis of fuselage frame under dynamic load condition with change in material. Composites like carbon fibre reinforced plastics [CFRP] and glass fibre reinforced plastics [GFRP] are compared with traditional aluminium alloy Al-7075. The frame is subjected to impact test by dropping it at a velocity of 30 ft. / secs from a height of 86 inch from its centre of gravity. These parameters are considered in event of failure of landing gear, and an aircraft is subject to belly landing or gear-up landing. The shear flow is calculated due to impact force which acts in radial direction. The frame is analysed under static structural and explicit dynamic load conditions. Geometry is created in ANSYS Design Modeler. Analysis setup is created using

  17. Analysis of Tire Tractive Performance on Deformable Terrain by Finite Element-Discrete Element Method

    Science.gov (United States)

    Nakashima, Hiroshi; Takatsu, Yuzuru

    The goal of this study is to develop a practical and fast simulation tool for soil-tire interaction analysis, where finite element method (FEM) and discrete element method (DEM) are coupled together, and which can be realized on a desktop PC. We have extended our formerly proposed dynamic FE-DE method (FE-DEM) to include practical soil-tire system interaction, where not only the vertical sinkage of a tire, but also the travel of a driven tire was considered. Numerical simulation by FE-DEM is stable, and the relationships between variables, such as load-sinkage and sinkage-travel distance, and the gross tractive effort and running resistance characteristics, are obtained. Moreover, the simulation result is accurate enough to predict the maximum drawbar pull for a given tire, once the appropriate parameter values are provided. Therefore, the developed FE-DEM program can be applied with sufficient accuracy to interaction problems in soil-tire systems.

  18. Model Reduction in Dynamic Finite Element Analysis of Lightweight Structures

    DEFF Research Database (Denmark)

    Flodén, Ola; Persson, Kent; Sjöström, Anders

    2012-01-01

    models may be created by assembling models of floor and wall structures into large models of complete buildings. When assembling the floor and wall models, the number of degrees of freedom quickly increases to exceed the limits of computer capacity, at least in a reasonable amount of computational time...... Hz. Three different methods of model reduction were investigated; Guyan reduction, component mode synthesis and a third approach where a new finite element model was created with structural elements. Eigenvalue and steady-state analyses were performed in order to compare the errors...

  19. Elemental characterization of Brazilian beans using neutron activation analysis

    International Nuclear Information System (INIS)

    Lilian Seiko Kato; Nadai Fernandes, E.A. De; Marcio Arruda Bacchi; Gabriel Adrian Sarries; Andres Enrique Lai Reyes

    2015-01-01

    Beans are important for many developing countries as a source of protein and mineral nutrients. Here, ten commercial types of Brazilian beans, from the species Phaseolus vulgaris (common beans) and Vigna unguiculata (cowpeas), were analyzed by neutron activation analysis for the determination of Br, Ca, Co, Cs, Fe, K, Mo, Na, Rb, Sc and Zn. There were statistical differences (p/0.05) amongst the commercial types, except for Br, Rb and Sc. In general, non-essential elements showed high variability, indicating that the origin of beans had a strong influence on the mass fraction of such elements. (author)

  20. Fast XRF analysis of mineral elements in dental composites

    International Nuclear Information System (INIS)

    Preoteasa, E. A.; Constantinescu, B.; Preoteasa, E.

    2001-01-01

    Dental composites, made of particles of glass, ceramics or quartz embedded in an organic polymer matrix, extensively replaced silver amalgam in tooth fillings and enabled new applications for restorative dentistry. Long-term alteration of dental fillings together with market pressure motivates the development of composites at a high rate, largely by progress of materials forming their mineral phase. Therefore, dental composites constantly bring at the interface with enamel and dentine new elements foreign to the organism, whose biological action has not been studied. Atomic and nuclear methods for surface multielemental analysis have been used in dental research but not for composites. X-ray fluorescence (XRF) is suited for the fast microanalytical screening of the elements and of their changes at the biomaterial's surface. The potential of radioisotope-excited XRF for the analysis of dental composites has been examined. Flat disk-shaped samples of composites have been prepared and polymerized chemically or by irradiation with intense 420-500 nm light. The measurements were performed with a spectrometric chain containing a 30 mCi source of 241 Am, a Si(Li) detector, and a multichannel analyzer. The spectra were built up for 2000-6000 sec. The characteristic X lines were integrated and normalized to source lines. The following Z ≥ 20 elements were detected in the studied composites: Ba only in Charisma (Kulzer) and Pekafill (Bayer); Zr, Ba, Yb in Tetric Ceram, and Ca, Ba, Yb together with traces of possibly Ti and Fe in Ariston (both from Vivadent); Zr, Hf in Valux Plus (3M Dental); and Sr, Ba together with some trace element, seemingly Cu, in F2000 Compomer (3M Dental) and with other trace elements like Ca, Fe in Surefil (Dentsply). Among older materials, Concise (3M Dental) contained only light (Z 3 that releases F for protection of enamel and dentine. Yb, Zr, Ba, Hf improve the radiological opacity of the materials. Some elements may accompany others as

  1. Finite elements for non-linear analysis of pipelines

    International Nuclear Information System (INIS)

    Benjamim, A.C.; Ebecken, N.F.F.

    1982-01-01

    The application of a three-dimensional lagrangian formulation for the great dislocations analysis and great rotation of pipelines systems is studied. This formulation is derived from the soil mechanics and take into account the shear stress effects. Two finite element models are implemented. The first, of right axis, uses as interpolation functions the conventional gantry functions, defined in relation to mobile coordinates. The second, of curve axis and variable cross sections, is obtained from the degeneration of the three-dimensional isoparametric element, and uses as interpolation functions third degree polynomials. (E.G.) [pt

  2. Trace element analysis in rheumatoid arthritis under chrysotherapy

    International Nuclear Information System (INIS)

    Lecomte, R.; Paradis, P.; Monaro, S.; Barrette, M.; Lamoureux, G.; Menard, H.A.

    1981-01-01

    Proton induced X-ray emission (PIXE) analysis is used to measure trace element concentrations in blood serum from patients with rheumatoid arthritis. Initially trace element contaminations in blood-collecting and storing devices are determined. Then mean values and nyctemeral cycles are measured both in normal subjects and patients with rheumatoid arthritis and other similar pathologies. Abnormal concentrations of Cu and Zn and anomalies in the nyctemeral cycle are found in the patients. In the second phase of the project, the special case of chrysotherapeutically treated (gold salt treatment) rheumatoid arthritis patients is studied for extended periods of time (up to 53 weeks). (orig.)

  3. Stress analysis of heated concrete using finite elements

    International Nuclear Information System (INIS)

    Majumdar, P.; Gupta, A.; Marchertas, A.

    1994-01-01

    Described is a finite element analysis of concrete, which is subjected to rapid heating. Using thermal mass transport calculation, the moisture content, temperature and pore pressure distribution over space and time is obtained first. From these effects, stress at various points of the concrete are computed using the finite element method. Contribution to the stress formulation comes from three components, namely the thermal expansion, pore pressure, and the shrinkage of concrete due to moisture loss (from dehydration). The material properties of concrete are assumed to be homogeneous, elastic, and cracking is not taken into consideration. (orig.)

  4. Fourier analysis of finite element preconditioned collocation schemes

    Science.gov (United States)

    Deville, Michel O.; Mund, Ernest H.

    1990-01-01

    The spectrum of the iteration operator of some finite element preconditioned Fourier collocation schemes is investigated. The first part of the paper analyses one-dimensional elliptic and hyperbolic model problems and the advection-diffusion equation. Analytical expressions of the eigenvalues are obtained with use of symbolic computation. The second part of the paper considers the set of one-dimensional differential equations resulting from Fourier analysis (in the tranverse direction) of the 2-D Stokes problem. All results agree with previous conclusions on the numerical efficiency of finite element preconditioning schemes.

  5. Comparative analysis of Carnaval II Library

    International Nuclear Information System (INIS)

    Santos Bastos, W. dos

    1981-01-01

    The Carnaval II cross sections library from the french fast reactor calculation system is evaluated in two ways: 1 0 ) a comparative analysis of the calculations system for fast reactors at IEN (Instituto de Engenharia Nuclear) using a 'benchmark' model is done; 2 0 ) a comparative analysis in relation to the french system itself is also done, using calculations realized with two versions of the french library: the SETR-II and the CARNAVAL IV, the first one being anterior and the second one posterior to the Carnaval II version, the one used by IEN. (Author) [pt

  6. 3-dimensional earthquake response analysis of embedded reactor building using hybrid model of boundary elements and finite elements

    International Nuclear Information System (INIS)

    Muto, K.; Motosaka, M.; Kamata, M.; Masuda, K.; Urao, K.; Mameda, T.

    1985-01-01

    In order to investigate the 3-dimensional earthquake response characteristics of an embedded structure with consideration for soil-structure interaction, the authors have developed an analytical method using 3-dimensional hybrid model of boundary elements (BEM) and finite elements (FEM) and have conducted a dynamic analysis of an actual nuclear reactor building. This paper describes a comparative study between two different embedment depths in soil as elastic half-space. As the results, it was found that the earthquake response intensity decreases with the increase of the embedment depth and that this method was confirmed to be effective for investigating the 3-D response characteristics of embedded structures such as deflection pattern of each floor level, floor response spectra in high frequency range. (orig.)

  7. Finite element analysis of structures through unified formulation

    CERN Document Server

    Carrera, Erasmo; Petrolo, Marco; Zappino, Enrico

    2014-01-01

    The finite element method (FEM) is a computational tool widely used to design and analyse  complex structures. Currently, there are a number of different approaches to analysis using the FEM that vary according to the type of structure being analysed: beams and plates may use 1D or 2D approaches, shells and solids 2D or 3D approaches, and methods that work for one structure are typically not optimized to work for another. Finite Element Analysis of Structures Through Unified Formulation deals with the FEM used for the analysis of the mechanics of structures in the case of linear elasticity. The novelty of this book is that the finite elements (FEs) are formulated on the basis of a class of theories of structures known as the Carrera Unified Formulation (CUF). It formulates 1D, 2D and 3D FEs on the basis of the same ''fundamental nucleus'' that comes from geometrical relations and Hooke''s law, and presents both 1D and 2D refined FEs that only have displacement variables as in 3D elements. It also covers 1D...

  8. Determination of the elemental composition of copper and bronze objects by neutron activation analysis

    International Nuclear Information System (INIS)

    Hoelttae, P.; Rosenberg, R.J.

    1987-01-01

    A method for the elemental analysis of copper and bronze objects is described. Na, Co, Ni, Cu, Zn, As, Ag, Sn, Sb, W, Ir and Au are determined through instrumental neutron activation analysis. Mg, Al, V, Ti and Mn are determined after chemical separation using anionic exchange. The detection limits for a number of other elements are also given. Results for NBS standard reference materials are presented and the results are compared with the recommended values. The agreement is good. The results of the analysis of five ancient bronze and two copper objects are also presented. (author) 3 refs.; 4 tabs

  9. A review of modern instrumental methods of elemental analysis of petroleum related material. Part 2

    International Nuclear Information System (INIS)

    Nadkarni, R.A.

    1991-01-01

    In this paper a review is presented of the state of the art in elemental analysis of petroleum-related materials (crude oil, gasoline, additives, and lubricants) using modern instrumental analysis techniques. The major instrumental techniques used for elemental analysis of petroleum products include atomic absorption spectrometry (both with flame and with graphite furnace atomizer), inductively coupled plasma atomic emission spectrometry, ion chromatography, microelemental methods, neutron activation, spark source mass spectrometry, and x-ray fluorescence. Each of these techniques is compared for its advantages, disadvantages, and typical applications in the petroleum field

  10. Determination of the elemental composition of copper and bronze objects by neutron activation analysis

    International Nuclear Information System (INIS)

    Hoelttae, P.; Rosenberg, R.J.

    1986-01-01

    A method for the elemental analysis of copper and bronze objects is described. Na, Co, Ni, Cu, Zn, As, Ag, Sn, Sb, W, Ir and Au are determined through instrumental neutron activation analysis. Mg, Al, V, Ti and Mn are determined after chemical separation using anionic exchange. The detection limits for a number of other elements are also given. Results for NBS standard reference materials are presented and the results compared with the recommended values. The agreement is good. The results of the analysis of five ancient bronze and two copper objects are presented. (author)

  11. Trace elements in precious and common opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Smallwood, A.

    1997-01-01

    Neutron activation analysis (NAA) was used to determine the concentration of trace elements in 44 precious and 52 common opals sampled from a number of recognised fields within Australia. The purpose of this study was to determine if precious and common opals of the same colour and location have the same or a different trace element profile. Similar numbers of black, white and grey samples were studied in each case. In most cases, common opals had a significantly higher concentration of certain trace elements when compared with precious opals. (author)

  12. Sample preparation procedure for PIXE elemental analysis on soft tissues

    International Nuclear Information System (INIS)

    Kubica, B.; Kwiatek, W.M.; Dutkiewicz, E.M.; Lekka, M.

    1997-01-01

    Trace element analysis is one of the most important field in analytical chemistry. There are several instrumental techniques which are applied for determinations of microscopic elemental content. The PIXE (Proton Induced X-ray Emission) technique is one of the nuclear techniques that is commonly applied for such purpose due to its multielemental analysis possibilities. The aim of this study was to establish the optimal conditions for target preparation procedure. In this paper two different approaches to the topic are presented and widely discussed. The first approach was the traditional pellet technique and the second one was mineralization procedure. For the analysis soft tissue such as liver was used. Some results are also presented on water samples. (author)

  13. OXYGEN PRESSURE REGULATOR DESIGN AND ANALYSIS THROUGH FINITE ELEMENT MODELING

    Directory of Open Access Journals (Sweden)

    Asterios KOSMARAS

    2017-05-01

    Full Text Available Oxygen production centers produce oxygen in high pressure that needs to be defused. A regulator is designed and analyzed in the current paper for medical use in oxygen production centers. This study aims to design a new oxygen pressure regulator and perform an analysis using Finite Element Modeling in order to evaluate its working principle. In the design procedure,the main elements and the operating principles of a pressure regulator are taking into account. The regulator is designed and simulations take place in order to assessthe proposed design. Stress analysis results are presented for the main body of the regulator, as well as, flow analysis to determine some important flow characteristics in the inlet and outlet of the regulator.

  14. Comparison of neutron activation analysis with other instrumental methods for elemental analysis of airborne particulate matter

    International Nuclear Information System (INIS)

    Regge, P. de; Lievens, F.; Delespaul, I.; Monsecour, M.

    1976-01-01

    A comparison of instrumental methods, including neutron activation analysis, X-ray fluorescence spectrometry, atomic absorption spectrometry and emission spectrometry, for the analysis of heavy metals in airborne particulate matter is described. The merits and drawbacks of each method for the routine analysis of a large number of samples are discussed. The sample preparation technique, calibration and statistical data relevant to each method are given. Concordant results are obtained by the different methods for Co, Cu, Ni, Pb and Zn. Less good agreement is obtained for Fe, Mn and V. The results are not in agreement for the elements Cd and Cr. Using data obtained on the dust sample distributed by Euratom-ISPRA within the framework of an interlaboratory comparison, the accuracy of each method for the various elements is estimated. Neutron activation analysis was found to be the most sensitive and accurate of the non-destructive analysis methods. Only atomic absorption spectrometry has a comparable sensitivity, but requires considerable preparation work. X-ray fluorescence spectrometry is less sensitive and shows biases for Cr and V. Automatic emission spectrometry with simultaneous measurement of the beam intensities by photomultipliers is the fastest and most economical technique, though at the expense of some precision and sensitivity. (author)

  15. Finite Element Residual Stress Analysis of Planetary Gear Tooth

    Directory of Open Access Journals (Sweden)

    Jungang Wang

    2013-01-01

    Full Text Available A method to simulate residual stress field of planetary gear is proposed. In this method, the finite element model of planetary gear is established and divided to tooth zone and profile zone, whose different temperature field is set. The gear's residual stress simulation is realized by the thermal compression stress generated by the temperature difference. Based on the simulation, the finite element model of planetary gear train is established, the dynamic meshing process is simulated, and influence of residual stress on equivalent stress of addendum, pitch circle, and dedendum of internal and external meshing planetary gear tooth profile is analyzed, according to non-linear contact theory, thermodynamic theory, and finite element theory. The results show that the equivalent stresses of planetary gear at both meshing and nonmeshing surface are significantly and differently reduced by residual stress. The study benefits fatigue cracking analysis and dynamic optimization design of planetary gear train.

  16. Probabilistic finite elements for fracture and fatigue analysis

    Science.gov (United States)

    Liu, W. K.; Belytschko, T.; Lawrence, M.; Besterfield, G. H.

    1989-01-01

    The fusion of the probabilistic finite element method (PFEM) and reliability analysis for probabilistic fracture mechanics (PFM) is presented. A comprehensive method for determining the probability of fatigue failure for curved crack growth was developed. The criterion for failure or performance function is stated as: the fatigue life of a component must exceed the service life of the component; otherwise failure will occur. An enriched element that has the near-crack-tip singular strain field embedded in the element is used to formulate the equilibrium equation and solve for the stress intensity factors at the crack-tip. Performance and accuracy of the method is demonstrated on a classical mode 1 fatigue problem.

  17. Groundwater flow analysis using mixed hybrid finite element method for radioactive waste disposal facilities

    International Nuclear Information System (INIS)

    Aoki, Hiroomi; Shimomura, Masanori; Kawakami, Hiroto; Suzuki, Shunichi

    2011-01-01

    In safety assessments of radioactive waste disposal facilities, ground water flow analysis are used for calculating the radionuclide transport pathway and the infiltration flow rate of groundwater into the disposal facilities. For this type of calculations, the mixed hybrid finite element method has been used and discussed about the accuracy of ones in Europe. This paper puts great emphasis on the infiltration flow rate of groundwater into the disposal facilities, and describes the accuracy of results obtained from mixed hybrid finite element method by comparing of local water mass conservation and the reliability of the element breakdown numbers among the mixed hybrid finite element method, finite volume method and nondegenerated finite element method. (author)

  18. Comparative Modal Analysis of Sieve Hardware Designs

    Science.gov (United States)

    Thompson, Nathaniel

    2012-01-01

    The CMTB Thwacker hardware operates as a testbed analogue for the Flight Thwacker and Sieve components of CHIMRA, a device on the Curiosity Rover. The sieve separates particles with a diameter smaller than 150 microns for delivery to onboard science instruments. The sieving behavior of the testbed hardware should be similar to the Flight hardware for the results to be meaningful. The elastodynamic behavior of both sieves was studied analytically using the Rayleigh Ritz method in conjunction with classical plate theory. Finite element models were used to determine the mode shapes of both designs, and comparisons between the natural frequencies and mode shapes were made. The analysis predicts that the performance of the CMTB Thwacker will closely resemble the performance of the Flight Thwacker within the expected steady state operating regime. Excitations of the testbed hardware that will mimic the flight hardware were recommended, as were those that will improve the efficiency of the sieving process.

  19. Elemental misinterpretation in automated analysis of LIBS spectra.

    Science.gov (United States)

    Hübert, Waldemar; Ankerhold, Georg

    2011-07-01

    In this work, the Stark effect is shown to be mainly responsible for wrong elemental allocation by automated laser-induced breakdown spectroscopy (LIBS) software solutions. Due to broadening and shift of an elemental emission line affected by the Stark effect, its measured spectral position might interfere with the line position of several other elements. The micro-plasma is generated by focusing a frequency-doubled 200 mJ pulsed Nd/YAG laser on an aluminum target and furthermore on a brass sample in air at atmospheric pressure. After laser pulse excitation, we have measured the temporal evolution of the Al(II) ion line at 281.6 nm (4s(1)S-3p(1)P) during the decay of the laser-induced plasma. Depending on laser pulse power, the center of the measured line is red-shifted by 130 pm (490 GHz) with respect to the exact line position. In this case, the well-known spectral line positions of two moderate and strong lines of other elements coincide with the actual shifted position of the Al(II) line. Consequently, a time-resolving software analysis can lead to an elemental misinterpretation. To avoid a wrong interpretation of LIBS spectra in automated analysis software for a given LIBS system, we recommend using larger gate delays incorporating Stark broadening parameters and using a range of tolerance, which is non-symmetric around the measured line center. These suggestions may help to improve time-resolving LIBS software promising a smaller probability of wrong elemental identification and making LIBS more attractive for industrial applications.

  20. Mineral Element Concentrations in Vegetables Cultivated in Acidic Compared to Alkaline Areas of South Sweden

    Directory of Open Access Journals (Sweden)

    Ingegerd Rosborg

    2009-01-01

    Full Text Available A study in 1997, on mineral levels in acidic compared to alkaline well waters, and in women’s hair, revealed higher concentrations of a number of mineral elements like Ca, Mo and Se in alkaline waters and hair. Thus, median Ca levels were six times higher in well water and five times higher in hair from the alkaline area compared to the acidic area. This finding raised the probability of similar differences in vegetables from these areas. Thus, in the year 2006, 60 women who had participated in the study in 1997 were asked to cultivate parsley, lettuce, carrot and chive. During the spring of 2006, the women from the water and hair study of 1997, 30 of them from the acidic area and 30 women from the alkaline district cultivated vegetables: carrot (Daucus carota L, parsley (Petroselinum crispum, chive (Allium schoenoprasum and lettuce (Eruca sativa. The vegetables were harvested, and rinsed in tap water from the kitchens of the participating women in August. The concentrations of about 35 elements and ions were determined by ICP OES and ICP-MS predominantly. In addition, soil samples from the different cultivators were also analyzed for a number of elements. Lettuce and parsley showed the highest concentrations of mineral elements per gram dry weight. Only Mo concentrations were significantly higher in all the different vegetables from the alkaline district compared to vegetables from the acidic areas. On the other hand, the concentrations of Ba, Br, Mn, Rb and Zn were higher in all the different vegetables from the acidic area. In the soil, only pH and exchangeable Ca from the alkaline area were higher than from the acidic area, while exchangeable Fe, Mn and Na concentrations were higher in soils from the acidic area. Soil elements like Al, Fe, Li, Ni, Pb, Si, Ti, V, Zn and Zr were found in higher concentrations in lettuce and parsley, which were attributed to soil particles being splashed on the plants by the rain and absorbed by the leaves

  1. Finite element elastic-plastic analysis of LMFBR components

    International Nuclear Information System (INIS)

    Levy, A.; Pifko, A.; Armen, H. Jr.

    1978-01-01

    The present effort involves the development of computationally efficient finite element methods for accurately predicting the isothermal elastic-plastic three-dimensional response of thick and thin shell structures subjected to mechanical and thermal loads. This work will be used as the basis for further development of analytical tools to be used to verify the structural integrity of liquid metal fast breeder reactor (LMFBR) components. The methods presented here have been implemented into the three-dimensional solid element module (HEX) of the Grumman PLANS finite element program. These methods include the use of optimal stress points as well as a variable number of stress points within an element. This allows monitoring the stress history at many points within an element and hence provides an accurate representation of the elastic-plastic boundary using a minimum number of degrees of freedom. Also included is an improved thermal stress analysis capability in which the temperature variation and corresponding thermal strain variation are represented by the same functional form as the displacement variation. Various problems are used to demonstrate these improved capabilities. (Auth.)

  2. Comparative Economic Analysis of Beekeeping Using Traditional ...

    African Journals Online (AJOL)

    The study was carried out in Tabora and Katavi regions in the miombo woodlands of Tanzania. The overall objective of the study was to undertake a comparative economic analysis of beekeeping using improved or traditional beehives. Data were collected from 198 beekeepers that were randomly selected from a sampling ...

  3. Comparative analysis of technical efficiencies between compound ...

    African Journals Online (AJOL)

    This study was designed to compare the level of technical efficiency in the compound and non compound farms in Imo state. A multi-stage random sampling technique was used to select 120 food crop farmers from two out of the three agricultural zones in Imo state. Using the Chow (1960) analysis of covariance technique ...

  4. MycoCAP - Mycobacterium Comparative Analysis Platform.

    Science.gov (United States)

    Choo, Siew Woh; Ang, Mia Yang; Dutta, Avirup; Tan, Shi Yang; Siow, Cheuk Chuen; Heydari, Hamed; Mutha, Naresh V R; Wee, Wei Yee; Wong, Guat Jah

    2015-12-15

    Mycobacterium spp. are renowned for being the causative agent of diseases like leprosy, Buruli ulcer and tuberculosis in human beings. With more and more mycobacterial genomes being sequenced, any knowledge generated from comparative genomic analysis would provide better insights into the biology, evolution, phylogeny and pathogenicity of this genus, thus helping in better management of diseases caused by Mycobacterium spp.With this motivation, we constructed MycoCAP, a new comparative analysis platform dedicated to the important genus Mycobacterium. This platform currently provides information of 2108 genome sequences of at least 55 Mycobacterium spp. A number of intuitive web-based tools have been integrated in MycoCAP particularly for comparative analysis including the PGC tool for comparison between two genomes, PathoProT for comparing the virulence genes among the Mycobacterium strains and the SuperClassification tool for the phylogenic classification of the Mycobacterium strains and a specialized classification system for strains of Mycobacterium abscessus. We hope the broad range of functions and easy-to-use tools provided in MycoCAP makes it an invaluable analysis platform to speed up the research discovery on mycobacteria for researchers. Database URL: http://mycobacterium.um.edu.my.

  5. Medical and health-related trace element analysis by TXRF

    International Nuclear Information System (INIS)

    Greaves, E.D.

    2000-01-01

    The advantages offered with TXRF analysis by direct irradiation with monochromatic X-rays of tissue homogenates and body fluids make the technique appropriate for a number of medical and health related applications. The ability to detect low levels of toxic heavy elements is being used as an aid in accidental poisoning diagnosis and treatment, in treatment-induced toxicity control and as an accessory in medical and health research. Thus lead-in-whole-blood analysis is used in confirmation of diagnosis of victims of poisoning, or monitoring the evolution and efficiency of the clinical treatment. Measurement and control of plasma platinum levels of cancer patients undergoing chemotherapy with Pt-containing drugs includes: establishment of the drug level-tumor remission response, measurement of Pt plasma level curves and establishment of optimum dosage to minimize the nephrotoxicity of platinum, and bioequivalence comparisons of different commercially available platinum containing anticancer drugs. Analysis as an aid in clinical research applications includes: trace element determination of amniotic fluid in fetus malformation studies; analysis of brain specimens and cerebrospinal fluid in diagnosis of central nervous system disorders; the influence of trace elements in cataract genesis and the influence of heavy elements in semen quality in human reproduction studies. Human body samples require the use of monochromatized beams of x-rays in order to derive the special advantage of its use: i) The reduction in the spectrum background allowing direct irradiation of organic matter specimens. Hence human tissue and body fluids are prepared by simple procedures involving dilution, homogenization and standard addition avoiding the need for specimen digestion. This results in faster, cheaper methods that decrease sample contamination problems. ii) The presence of a large Compton scattered signal in the spectrum and its use as an internal standard reference allows further

  6. Non destructive multi elemental analysis using prompt gamma neutron activation analysis techniques: Preliminary results for concrete sample

    Energy Technology Data Exchange (ETDEWEB)

    Dahing, Lahasen Normanshah [School of Applied Physics, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia and Malaysian Nuclear Agency (Nuklear Malaysia), Bangi 43000, Kajang (Malaysia); Yahya, Redzuan [School of Applied Physics, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor (Malaysia); Yahya, Roslan; Hassan, Hearie [Malaysian Nuclear Agency (Nuklear Malaysia), Bangi 43000, Kajang (Malaysia)

    2014-09-03

    In this study, principle of prompt gamma neutron activation analysis has been used as a technique to determine the elements in the sample. The system consists of collimated isotopic neutron source, Cf-252 with HPGe detector and Multichannel Analysis (MCA). Concrete with size of 10×10×10 cm{sup 3} and 15×15×15 cm{sup 3} were analysed as sample. When neutrons enter and interact with elements in the concrete, the neutron capture reaction will occur and produce characteristic prompt gamma ray of the elements. The preliminary result of this study demonstrate the major element in the concrete was determined such as Si, Mg, Ca, Al, Fe and H as well as others element, such as Cl by analysis the gamma ray lines respectively. The results obtained were compared with NAA and XRF techniques as a part of reference and validation. The potential and the capability of neutron induced prompt gamma as tool for multi elemental analysis qualitatively to identify the elements present in the concrete sample discussed.

  7. Diagnosing MOV problems using comparative trace analysis

    International Nuclear Information System (INIS)

    Leon, R.L.

    1992-01-01

    The paper presents the concept of comparative trace analysis and shows it to be very effective in diagnosing motor operated valve (MOV) problems. Comparative trace analysis is simply the process of interpreting simultaneously gathered traces, each presenting a different perspective on the same series of events. The opening and closing of a motor operated valve is such a series of events. The simultaneous traces are obtained using Liberty Technologies' Valve Operation Test and Evaluation System (VOTES)reg-sign. The traces include stem thrust, motor current, motor power factor, motor power, switch actuations, vibration in three different frequency bands, spring pack displacement, and spring pack force. Spare and auxiliary channels enable additional key parameters to be measured, such as differential pressure and stem displacement. Though not specifically illustrated in this paper, the VOTES system also provides for FFT analysis on all traces except switches

  8. FINITE ELEMENT ANALYSIS OF TAPERED COMPOSITE PLATE GIRDER WITH A NON-LINEAR VARYING WEB DEPTH

    Directory of Open Access Journals (Sweden)

    Q. A. HASAN

    2017-11-01

    Full Text Available The paper presents Finite Element Analysis to determine the ultimate shear capacity of tapered composite plate girder. The effect of degree of taper on the ultimate shear capacity of tapered steel-concrete composite plate girder with a nonlinear varying web depth, effect of slenderness ratio on the ultimate shear capacity, and effect of flange stiffness on the ductility were considered as the parametric studies. Effect of concrete slab on the ultimate shear capacity of tapered plate girders was also considered and it was found to be so effective on the ultimate shear capacity of the tapered plate girder compared with the steel one. The accuracy of the finite element method is established by comparing the finite element with the results existing in the literature. The study was conducted using nonlinear finite element modelling with computer software LUSAS 14.7.

  9. Characteristic and analysis of structural elements of corporate social responsibility

    Directory of Open Access Journals (Sweden)

    J. S. Bilonog

    2015-04-01

    Full Text Available In this article attention is focused on social responsibility of business and on necessity to estimate its condition in Ukraine. Materials regarding elements and the principles of corporate social responsibility are structured. On this basis unification of quantitative elements of business social responsibility is offered according to which it is possible to carry out the analysis of the non­financial reporting. It is proposed to use not only quantitative techniques of data analysis but also refer to the qualitative ones. As a result of this, the analysis of social reports will be more productive and would minimize subjectivity of the researcher or representatives of the company which are responsible for presenting the information to the general public. The basic principles by which the companies can realize the strategy of corporate social responsibility are considered. Due to the empirical analysis of corporate reports expediency to use specified elements is proved. Reports of the companies in producing and non­productive sector are analyzed in more detail; features of displaying information on corporate social responsibility are defined. The attention to need of carrying out monitoring researches in the sphere of the corporate social reporting is updated.

  10. Comparison and determination of elemental composition in Korean space foods using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Yong-Sam Chung; Sun-Ha Kim; Gwang-Min Sun; Jong-Hwa Moon; Jong-Il Choi; Beom-Seok Song; Jae-Hun Kim

    2013-01-01

    A quantitative analysis of mineral contents in several kinds of foods is needed to obtain information on a comprehensive elemental composition as well as an investigation on the effects of human health and nutrition based on the dietary intake of mineral elements. In 2012, six kinds of new Korean space foods (KSF) such as sweet pumpkin porridge, dakgalbi (spicy grilled chicken), Manila clam porridge, ox leg bone-cabbage soup, ginseng-chicken porridge, and chicken curry rice were developed by KAERI, and the contents of more than 15 elements in the samples were determined using an instrumental neutron activation analysis. A certified reference material associated with a biological food sample was used for analytical quality control. The analytical results were evaluated according to the elemental concentrations with KSF samples and compared with the reported values. These results will be applied toward the identification of gamma-irradiated foods. (author)

  11. Determination of 28 elements in American cigarette tobacco by neutron-activation analysis

    International Nuclear Information System (INIS)

    Iskander, F.Y.; Bauer, T.L.; Klein, D.E.

    1986-01-01

    The concentrations of 28 toxic and other elements in cigarette tobacco of twelve brands commercially manufactured in the USA were determined using instrumental neutron-activation analysis. The elements determined were Al, As, Ba, Br, Ca, Ce, Cl, Co, Cr, Cs, Eu, Fe, Hf, K, La, Mg, Mn, Na, Ni, Rb, Sb, Sc, Se, Sr, Th, Ti, V and Zn. The concentrations of the determined elements in the American cigarettes were compared with the elemental concentrations reported for Iranian, Pakistani and Japanese brands. It was concluded that the concentrations of As, Br, Ca, Eu, K and Zn in the samples under investigation are lower than those reported for the analysis of University of Kentucky reference cigarettes, whereas the concentrations of Mn and Na are higher. The contents of Al, Cl, Co, Cr, Cs, Fe, La, Sb, Sc, and Se are similar to those in the reference cigarettes. (author)

  12. Finite element modelling and updating of friction stir welding (FSW joint for vibration analysis

    Directory of Open Access Journals (Sweden)

    Zahari Siti Norazila

    2017-01-01

    Full Text Available Friction stir welding of aluminium alloys widely used in automotive and aerospace application due to its advanced and lightweight properties. The behaviour of FSW joints plays a significant role in the dynamic characteristic of the structure due to its complexities and uncertainties therefore the representation of an accurate finite element model of these joints become a research issue. In this paper, various finite elements (FE modelling technique for prediction of dynamic properties of sheet metal jointed by friction stir welding will be presented. Firstly, nine set of flat plate with different series of aluminium alloy; AA7075 and AA6061 joined by FSW are used. Nine set of specimen was fabricated using various types of welding parameters. In order to find the most optimum set of FSW plate, the finite element model using equivalence technique was developed and the model validated using experimental modal analysis (EMA on nine set of specimen and finite element analysis (FEA. Three types of modelling were engaged in this study; rigid body element Type 2 (RBE2, bar element (CBAR and spot weld element connector (CWELD. CBAR element was chosen to represent weld model for FSW joints due to its accurate prediction of mode shapes and contains an updating parameter for weld modelling compare to other weld modelling. Model updating was performed to improve correlation between EMA and FEA and before proceeds to updating, sensitivity analysis was done to select the most sensitive updating parameter. After perform model updating, total error of the natural frequencies for CBAR model is improved significantly. Therefore, CBAR element was selected as the most reliable element in FE to represent FSW weld joint.

  13. Proposal for element size and time increment selection guideline by 3-D finite element method for elastic waves propagation analysis

    International Nuclear Information System (INIS)

    Ishida, Hitoshi; Meshii, Toshiyuki

    2008-01-01

    This paper proposes a guideline for selection of element size and time increment by 3-D finite element method, which is applied to elastic wave propagation analysis for a long distance of a large structure. An element size and a time increment are determined by quantitative evaluation of strain, which must be 0 on the analysis model with a uniform motion, caused by spatial and time discretization. (author)

  14. Rolling-element fatigue life of silicon nitride balls. [as compared to that of steel, ceramic, and cermet materials

    Science.gov (United States)

    Parker, R. J.; Zaretsky, E. V.

    1974-01-01

    The five-ball fatigue tester was used to evaluate silicon nitride as a rolling-element bearing material. Results indicate that hot-pressed silicon nitride running against steel may be expected to yield fatigue lives comparable to or greater than those of bearing quality steel running against steel at stress levels typical rolling-element bearing application. The fatigue life of hot-pressed silicon nitride is considerably greater than that of any ceramic or cermet tested. Computer analysis indicates that there is no improvement in the lives of 120-mm-bore angular--contact ball bearings of the same geometry operating at DN values from 2 to 4 million where hot-pressed silicon nitride balls are used in place of steel balls.

  15. National Launch System comparative economic analysis

    Science.gov (United States)

    Prince, A.

    1992-01-01

    Results are presented from an analysis of economic benefits (or losses), in the form of the life cycle cost savings, resulting from the development of the National Launch System (NLS) family of launch vehicles. The analysis was carried out by comparing various NLS-based architectures with the current Shuttle/Titan IV fleet. The basic methodology behind this NLS analysis was to develop a set of annual payload requirements for the Space Station Freedom and LEO, to design launch vehicle architectures around these requirements, and to perform life-cycle cost analyses on all of the architectures. A SEI requirement was included. Launch failure costs were estimated and combined with the relative reliability assumptions to measure the effects of losses. Based on the analysis, a Shuttle/NLS architecture evolving into a pressurized-logistics-carrier/NLS architecture appears to offer the best long-term cost benefit.

  16. Analysis of tracer elements in human hair using XRF

    International Nuclear Information System (INIS)

    Hou Jing; Gao Deyu; Zhao Li; Li Hong

    2004-01-01

    Using chemical addition method to calibrate absorption effect, trace element in human hair are analyzed with X-ray fluorescence (XRF). Based on practical samples of human hair, the relative matrix absorption efficienty is determined, and the relation ship between which and the most important componet Ca is fitted. The contents of Ca, Cu, Fe, Zn in the human hair are analyzed using the calibrated constants. A group of standard human hair samples are analyzed and the results are compared with the recommended value of the National Standard. The measured values show a good coincidence with the recommended values. Comparing to the GB, the deviations are Ca 0.28%, Fe 0.99%, Cu 2.6%, Zn 0; the relative errors are Ca 2.2%, Fe 1.7%, Cu 2.2%, Zn 1.1%, and the sensitivity is ≤2.2%. This method may be used to determine the tracing elements in human hair. (authors)

  17. Accurate determination of light elements by charged particle activation analysis

    International Nuclear Information System (INIS)

    Shikano, K.; Shigematsu, T.

    1989-01-01

    To develop accurate determination of light elements by CPAA, accurate and practical standardization methods and uniform chemical etching are studied based on determination of carbon in gallium arsenide using the 12 C(d,n) 13 N reaction and the following results are obtained: (1)Average stopping power method with thick target yield is useful as an accurate and practical standardization method. (2)Front surface of sample has to be etched for accurate estimate of incident energy. (3)CPAA is utilized for calibration of light element analysis by physical method. (4)Calibration factor of carbon analysis in gallium arsenide using the IR method is determined to be (9.2±0.3) x 10 15 cm -1 . (author)

  18. Sensitivity analysis overlaps of friction elements in cartridge seals

    Directory of Open Access Journals (Sweden)

    Žmindák Milan

    2018-01-01

    Full Text Available Cartridge seals are self-contained units consisting of a shaft sleeve, seals, and gland plate. The applications of mechanical seals are numerous. The most common example of application is in bearing production for automobile industry. This paper deals with the sensitivity analysis of overlaps friction elements in cartridge seal and their influence on the friction torque sealing and compressive force. Furthermore, it describes materials for the manufacture of sealings, approaches usually used to solution of hyperelastic materials by FEM and short introduction into the topic wheel bearings. The practical part contains one of the approach for measurement friction torque, which results were used to specifying the methodology and precision of FEM calculation realized by software ANSYS WORKBENCH. This part also contains the sensitivity analysis of overlaps friction elements.

  19. Screen-Printed Electrodes Modified with "Green" Metals for Electrochemical Stripping Analysis of Toxic Elements.

    Science.gov (United States)

    Economou, Anastasios

    2018-03-29

    This work reviews the field of screen-printed electrodes (SPEs) modified with "green" metals for electrochemical stripping analysis of toxic elements. Electrochemical stripping analysis has been established as a useful trace analysis technique offering many advantages compared to competing optical techniques. Although mercury has been the preferred electrode material for stripping analysis, the toxicity of mercury and the associated legal requirements in its use and disposal have prompted research towards the development of "green" metals as alternative electrode materials. When combined with the screen-printing technology, such environment-friendly metals can lead to disposable sensors for trace metal analysis with excellent operational characteristics. This review focuses on SPEs modified with Au, Bi, Sb, and Sn for stripping analysis of toxic elements. Different modification approaches (electroplating, bulk modification, use of metal precursors, microengineering techniques) are considered and representative applications are described. A developing related field, namely biosensing based on stripping analysis of metallic nanoprobe labels, is also briefly mentioned.

  20. Twenty years of analysis of light elements at the LARN

    International Nuclear Information System (INIS)

    Demortier, G.

    1992-01-01

    We review the applications of ion beam analysis of light elements performed in the LARN during the last twenty years. The works mainly concern: helium bubbles in aluminum foils, Li in aluminum alloys, carbon in high purity MgO crystals and in olivines, nitrogen bubbles in glass and implanted nitrogen in iron and aluminum, oxygen in YBaCuO superconductors, fluorine in tooth enamel and implanted fluorine in metals. (orig.)

  1. Instrumental neutron activation analysis in environmental studies of trace elements

    International Nuclear Information System (INIS)

    Salmon, L.

    1975-06-01

    The application of a routine instrumental nuclear method is described in relation to environmental surveys and studies. A working rather than formal review is made of the techniques applied with particular reference to the data processing methods involved. The elements measured by instrumental activation analysis were: Ag, Al, As, Au, Ba, Br, Ca, Ce, Cl, Cd, Co, Cr, Cs, Cu, Fe, Hg, I, In, La, Mn, Na, Ni, Pb, Rb, Sb, Sc, Se, Th, Ti, U, V, W, Zn. (author)

  2. Three dimensional mathematical model of tooth for finite element analysis

    Directory of Open Access Journals (Sweden)

    Puškar Tatjana

    2010-01-01

    Full Text Available Introduction. The mathematical model of the abutment tooth is the starting point of the finite element analysis of stress and deformation of dental structures. The simplest and easiest way is to form a model according to the literature data of dimensions and morphological characteristics of teeth. Our method is based on forming 3D models using standard geometrical forms (objects in programmes for solid modeling. Objective. Forming the mathematical model of abutment of the second upper premolar for finite element analysis of stress and deformation of dental structures. Methods. The abutment tooth has a form of a complex geometric object. It is suitable for modeling in programs for solid modeling SolidWorks. After analyzing the literature data about the morphological characteristics of teeth, we started the modeling dividing the tooth (complex geometric body into simple geometric bodies (cylinder, cone, pyramid,.... Connecting simple geometric bodies together or substricting bodies from the basic body, we formed complex geometric body, tooth. The model is then transferred into Abaqus, a computational programme for finite element analysis. Transferring the data was done by standard file format for transferring 3D models ACIS SAT. Results. Using the programme for solid modeling SolidWorks, we developed three models of abutment of the second maxillary premolar: the model of the intact abutment, the model of the endodontically treated tooth with two remaining cavity walls and the model of the endodontically treated tooth with two remaining walls and inserted post. Conclusion Mathematical models of the abutment made according to the literature data are very similar with the real abutment and the simplifications are minimal. These models enable calculations of stress and deformation of the dental structures. The finite element analysis provides useful information in understanding biomechanical problems and gives guidance for clinical research.

  3. Preparation of hair and nail samples for trace element analysis

    International Nuclear Information System (INIS)

    Scoble, H.A.; Litman, R.

    1978-01-01

    The method of washing of human hair and nail samples is examined by neutron activation and γ-ray analysis. The amounts of Na, K, Br, Au, Zn, and La that are removed by successive washings determine the optimum number of washing for removing these trace elements as surface contaminants. A total solution contact time with the nails is 5 minutes, and leaching effcts are observed after 6 washings

  4. Applications of mixed Petrov-Galerkin finite element methods to transient and steady state creep analysis

    International Nuclear Information System (INIS)

    Guerreiro, J.N.C.; Loula, A.F.D.

    1988-12-01

    The mixed Petrov-Galerkin finite element formulation is applied to transiente and steady state creep problems. Numerical analysis has shown additional stability of this method compared to classical Galerkin formulations. The accuracy of the new formulation is confirmed in some representative examples of two dimensional and axisymmetric problems. (author) [pt

  5. Nonlinear finite element analysis of reinforced and prestressed concrete shells with edge beams

    International Nuclear Information System (INIS)

    Srinivasa Rao, P.; Duraiswamy, S.

    1994-01-01

    The structural design of reinforced and prestressed concrete shells demands the application of nonlinear finite element analysis (NFEM) procedures to ensure safety and serviceability. In this paper the details of a comprehensive NFEM program developed are presented. The application of the program is highlighted by solving two numerical problems and comparing the results with experimental results. (author). 20 refs., 15 figs

  6. A finite element model for the stress and flexibility analysis of curved pipes

    International Nuclear Information System (INIS)

    Guerreiro, J.N.C.

    1987-03-01

    We present a finite element model for the analysis of pipe bends with flanged ends or flanged tangents. Comments are made on the consideration of the internal pressure load. Flexibility and stress instensification factores obtained with the present model are compared with others available. (Author) [pt

  7. A New Approach to Sequence Analysis Exemplified by Identification of cis-Elements in Abscisic Acid Inducible Promoters

    DEFF Research Database (Denmark)

    Busk, Peter Kamp; Hallin, Peter Fischer; Salomon, Jesper

    -regulatory elements. We have developed a method for identifying short, conserved motifs in biological sequences such as proteins, DNA and RNA5. This method was used for analysis of approximately 2000 Arabidopsis thaliana promoters that have been shown by DNA array analysis to be induced by abscisic acid6....... These promoters were compared to 28000 promoters that are not induced by abscisic acid. The analysis identified previously described ABA-inducible promoter elements such as ABRE, CE3 and CRT1 but also new cis-elements were found. Furthermore, the list of DNA elements could be used to predict ABA...

  8. Elemental analysis of sub-hourly ambient aerosol collections

    Energy Technology Data Exchange (ETDEWEB)

    Kidwell, C.B.; Ondov, J.M. [University of Maryland, College Park, MD (USA). Dept. of Chemical & Biochemistry

    2004-03-01

    Simultaneous multielement graphite furnace atomic absorption spectrometry was used to determine Al, As, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Sb, Se, and Zn in ambient air sampled at 170 L.min{sup -1} for 30 min and collected as a slurry after dynamic preconcentration. Analyses of slurries of NIST SRM 1648, Urban Particulate Matter, were typically within 10% of expected values for all elements except Al, Cr, and Fe, elements for which deviations were mostly due to difficulties in transferring large particles. This problem will be reduced for urban fine particulate matter samples (PM2.5). Trends in the concentrations of elemental source markers were readily correlated with wind direction and other meteorological factors to identify the influences of local industrial emissions, including motor vehicle traffic, coal- and oil-fired power plants, and municipal incinerators. Factor analysis was applied to the 88-sample data set to extract 7 factors: urban dust, meteorological factors, incinerators, coal- fired power plants, Tour Bus emission, unknown As source, and oil-fired power plants. Factor analysis was also applied to an 18-sample data set representing 2.5 h averages of the 30 min data to simulate the effect of longer sample collection times. Only 6 factors were extracted from this data set, which shows that increased temporal resolution enhances the power of factor analysis to resolve sources. These results indicate that a wealth of detailed information is revealed at this level of temporal resolution.

  9. Finite element analysis of the cyclic indentation of bilayer enamel

    International Nuclear Information System (INIS)

    Jia, Yunfei; Xuan, Fu-zhen; Chen, Xiaoping; Yang, Fuqian

    2014-01-01

    Tooth enamel is often subjected to repeated contact and often experiences contact deformation in daily life. The mechanical strength of the enamel determines the biofunctionality of the tooth. Considering the variation of the rod arrangement in outer and inner enamel, we approximate enamel as a bilayer structure and perform finite element analysis of the cyclic indentation of the bilayer structure, to mimic the repeated contact of enamel during mastication. The dynamic deformation behaviour of both the inner enamel and the bilayer enamel is examined. The material parameters of the inner and outer enamel used in the analysis are obtained by fitting the finite element results with the experimental nanoindentation results. The penetration depth per cycle at the quasi-steady state is used to describe the depth propagation speed, which exhibits a two-stage power-law dependence on the maximum indentation load and the amplitude of the cyclic load, respectively. The continuous penetration of the indenter reflects the propagation of the plastic zone during cyclic indentation, which is related to the energy dissipation. The outer enamel serves as a protective layer due to its great resistance to contact deformation in comparison to the inner enamel. The larger equivalent plastic strain and lower stresses in the inner enamel during cyclic indentation, as calculated from the finite element analysis, indicate better crack/fracture resistance of the inner enamel. (paper)

  10. Finite element analysis of the cyclic indentation of bilayer enamel

    Science.gov (United States)

    Jia, Yunfei; Xuan, Fu-zhen; Chen, Xiaoping; Yang, Fuqian

    2014-04-01

    Tooth enamel is often subjected to repeated contact and often experiences contact deformation in daily life. The mechanical strength of the enamel determines the biofunctionality of the tooth. Considering the variation of the rod arrangement in outer and inner enamel, we approximate enamel as a bilayer structure and perform finite element analysis of the cyclic indentation of the bilayer structure, to mimic the repeated contact of enamel during mastication. The dynamic deformation behaviour of both the inner enamel and the bilayer enamel is examined. The material parameters of the inner and outer enamel used in the analysis are obtained by fitting the finite element results with the experimental nanoindentation results. The penetration depth per cycle at the quasi-steady state is used to describe the depth propagation speed, which exhibits a two-stage power-law dependence on the maximum indentation load and the amplitude of the cyclic load, respectively. The continuous penetration of the indenter reflects the propagation of the plastic zone during cyclic indentation, which is related to the energy dissipation. The outer enamel serves as a protective layer due to its great resistance to contact deformation in comparison to the inner enamel. The larger equivalent plastic strain and lower stresses in the inner enamel during cyclic indentation, as calculated from the finite element analysis, indicate better crack/fracture resistance of the inner enamel.

  11. Complex of the equipment for instrumental element analysis

    International Nuclear Information System (INIS)

    Borisov, G.I.; Komkov, M.M.; Kuz'michev, V.A.

    1986-01-01

    Complex of the equipment for instrumental element analysis at the IR-8 reactor is designed, fabricated and taken into operation. The complex is provided with a multichannel system of vacuum pneumatic transport with radiation positions in the reactor horizontal tangential channel for neutron-activation analysis by short-lived isotopes; specialized dry vertical channels in a beryllium reflector of the reactor and remote system of radioactive sample replacement for neutron-activation analysis by long-lived isotopes; a specialized horizontal tangential channel for neutron beam extraction by means of a beryllium converter and remote device for studied sample replacement under radiation and measurement of prompt γ-radiation for neutron-radiation analysis; a measuring center using minicomputers for experimental data accumulation and processing and analysis control

  12. A proposal for a determination method of element division on an analytical model for finite element elastic waves propagation analysis

    International Nuclear Information System (INIS)

    Ishida, Hitoshi; Meshii, Toshiyuki

    2010-01-01

    This study proposes an element size selection method named the 'Impact-Meshing (IM) method' for a finite element waves propagation analysis model, which is characterized by (1) determination of element division of the model with strain energy in the whole model, (2) static analysis (dynamic analysis in a single time step) with boundary conditions which gives a maximum change of displacement in the time increment and inertial (impact) force caused by the displacement change. In this paper, an example of application of the IM method to 3D ultrasonic wave propagation problem in an elastic solid is described. These examples showed an analysis result with a model determined by the IM method was convergence and calculation time for determination of element subdivision was reduced to about 1/6 by the IM Method which did not need determination of element subdivision by a dynamic transient analysis with 100 time steps. (author)

  13. Evaluating the risks of clinical research: direct comparative analysis.

    Science.gov (United States)

    Rid, Annette; Abdoler, Emily; Roberson-Nay, Roxann; Pine, Daniel S; Wendler, David

    2014-09-01

    Many guidelines and regulations allow children and adolescents to be enrolled in research without the prospect of clinical benefit when it poses minimal risk. However, few systematic methods exist to determine when research risks are minimal. This situation has led to significant variation in minimal risk judgments, raising concern that some children are not being adequately protected. To address this concern, we describe a new method for implementing the widely endorsed "risks of daily life" standard for minimal risk. This standard defines research risks as minimal when they do not exceed the risks posed by daily life activities or routine examinations. This study employed a conceptual and normative analysis, and use of an illustrative example. Different risks are composed of the same basic elements: Type, likelihood, and magnitude of harm. Hence, one can compare the risks of research and the risks of daily life by comparing the respective basic elements with each other. We use this insight to develop a systematic method, direct comparative analysis, for implementing the "risks of daily life" standard for minimal risk. The method offers a way of evaluating research procedures that pose the same types of risk as daily life activities, such as the risk of experiencing anxiety, stress, or other psychological harm. We thus illustrate how direct comparative analysis can be applied in practice by using it to evaluate whether the anxiety induced by a respiratory CO2 challenge poses minimal or greater than minimal risks in children and adolescents. Direct comparative analysis is a systematic method for applying the "risks of daily life" standard for minimal risk to research procedures that pose the same types of risk as daily life activities. It thereby offers a method to protect children and adolescents in research, while ensuring that important studies are not blocked because of unwarranted concerns about research risks.

  14. Comparative Analysis of Terrorists’ Communication Strategies

    Directory of Open Access Journals (Sweden)

    Denis Alexandrovich Zhuravliev

    2011-01-01

    Full Text Available There is a wide-spread approach in a research literature to regard terrorism as a communicative process. From this point of view, the author offers a comparative analysis of the three most common communication strategies of terrorist groups, including transforming the role of the mass media, the Internet and a combined approach. The author also argues that a particular communication strategy determines a structure of a terrorist organization.

  15. Neutron activation analysis of rare earths and some other elements in material of geochemical interest

    International Nuclear Information System (INIS)

    Brunfelt, A.O.

    1975-01-01

    ngle-element methods for the determination by neutron activation analysis of antimony, chromium, phosphorus, selenium and silver in international geochemical standard rocks, and the determination of rare earth elements i in standard rocks and apatites are described and discussed in twelve previously published papers, and in an eighteen page summary. Chemical separationtechniques are also discussed and the results are compared with previously obtained results with the same standard rocks. The accuracy of neutron activation analysis is discussed in comparison with isotope dilution mass spectroscopy, atomic absorption, gas chromatography and spark source mass spectrometry. (JIW)

  16. A solution for the integration of finite element analysis in a ship design environment

    International Nuclear Information System (INIS)

    Finifter, D.; Wyniecki, P.; Castel, J. de

    1982-01-01

    The DEMAIN system for the pre- and post-processing of finite element analyses of ship structures is presented. It is shown that this new modelling concept, although being self-contained and specialized, has features which relate it to computer-aided design applications of a more general nature. Thus, compared to other finite element pre/post-processors, it allows a more natural occurrence of the structural analysis task in the design flow and can be considered a major step towards an integrated design and analysis system. (orig.)

  17. Multidimensional elemental analysis with the Sandia nuclear microprobe

    International Nuclear Information System (INIS)

    Doyle, B.L.

    1988-01-01

    It is well known that many of the ion beam analysis techniques such as Rutherford backscattering spectrometry, elastic recoil detection, resonant and nonresonant nuclear reaction analysis can be used to nondestructively obtain concentration depth profiles of elements in solids. When these techniques are combined with the small beam spot capabilities of a scanned nuclear microprobe, sample composition can be determined in up to three dimensions. This paper will review the various procedures used to collect and analyze multidimensional data using the Sandia nuclear microprobe. In addition, examples of how these data are being used in the study of materials will be shown. (author)

  18. Comparative study of the nutritional composition and toxic elements of farmed and wild Chanodichthys mongolicus

    Science.gov (United States)

    Jiang, Haifeng; Cheng, Xiaofei; Geng, Longwu; Tang, Shizhan; Tong, Guangxiang; Xu, Wei

    2017-07-01

    Information of the difference in quality between farmed and wild fish is central to better ensuring fish products produced in aquaculture meet regulatory and consumer requirements. Proximate composition, amino acid and fatty acid profiles, and toxic elements contents of farmed and wild Chanodichthys mongolicus were established and compared. Significantly higher crude protein content while lower moisture content in farmed fish compared to wild fish were observed ( Pacids (TAA), total essential amino acids (TEAA), total non-essential amino acids (TNEAA) and total delicious amino acids (TDAA) in farmed fish were all significantly higher than those in the wild equivalent ( Pacid profiles in both farmed and wild C. mongolicus were dominated by monounsaturated fatty acid (MUFA), with farmed fish contained much more MUFA content compared to wild counterpart ( Pacid (PUFA) including eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) than farmed fish ( Pacid (C18:2n6) were the predominant PUFA in wild and farmed C. mongolicus, respectively. Moreover, farmed fish displayed an overall lower toxic element levels (As, Cd, Pb and Hg) in comparison with wild fish, and both were far lower than the established limit standard. In conclusion, our results suggest that the nutritional quality of farmed C. mongolicus was inferior to their wild counterpart with respect to fatty acids nutrition, and therefore further studies should focus on the improving C. mongolicus diet in order to enhance the overall nutritional composition.

  19. Embedded Hyperchaotic Generators: A Comparative Analysis

    Science.gov (United States)

    Sadoudi, Said; Tanougast, Camel; Azzaz, Mohamad Salah; Dandache, Abbas

    In this paper, we present a comparative analysis of FPGA implementation performances, in terms of throughput and resources cost, of five well known autonomous continuous hyperchaotic systems. The goal of this analysis is to identify the embedded hyperchaotic generator which leads to designs with small logic area cost, satisfactory throughput rates, low power consumption and low latency required for embedded applications such as secure digital communications between embedded systems. To implement the four-dimensional (4D) chaotic systems, we use a new structural hardware architecture based on direct VHDL description of the forth order Runge-Kutta method (RK-4). The comparative analysis shows that the hyperchaotic Lorenz generator provides attractive performances compared to that of others. In fact, its hardware implementation requires only 2067 CLB-slices, 36 multipliers and no block RAMs, and achieves a throughput rate of 101.6 Mbps, at the output of the FPGA circuit, at a clock frequency of 25.315 MHz with a low latency time of 316 ns. Consequently, these good implementation performances offer to the embedded hyperchaotic Lorenz generator the advantage of being the best candidate for embedded communications applications.

  20. Strain-based finite elements for the analysis of cylinders with holes and normally intersecting cylinders

    International Nuclear Information System (INIS)

    Sabir, A.B.

    1983-01-01

    A finite element solution to the problems of stress distribution for cylindrical shells with circular and elliptical holes and also for normally intersecting thin elastic cylindrical shells is given. Quadrilateral and triangular curved finite elements are used in the analysis. The elements are of a new class, based on simple independent generalised strain functions insofar as this is allowed by the compatibility equations. The elements also satisfy exactly the requirements of strain-free-rigid body displacements and uses only the external 'geometrical' nodal degrees of freedom to avoid the difficulties associated with unnecessary internal degrees of freedom. We first develop strain based quadrilateral and triangular elements and apply them to the solution of the problem of stress concentrations in the neighbourhood of small and large circular and elliptical holes when the cylinders are subjected to a uniform axial tension. These results are compared with analytical solutions based on shallow shell approximations and show that the use of these strain based elements obviates the need for using an inordinately large number of elements. Normally intersecting cylinders are common configurations in structural components for nuclear reactor systems and design information for such configurations are generally lacking. The opportunity is taken in the present paper to provide a finite element solution to this problem. A method of substructing will be introduced to enable a solution to the large number of non banded set of simultaneous equations encountered. (orig./HP)

  1. Finite element analysis of beam-to-column joints in steel frames under cyclic loading

    Directory of Open Access Journals (Sweden)

    Elsayed Mashaly

    2011-03-01

    Full Text Available The aim of this paper is to present a simple and accurate three-dimensional (3D finite element model (FE capable of predicting the actual behavior of beam-to-column joints in steel frames subjected to lateral loads. The software package ANSYS is used to model the joint. The bolted extended-end-plate connection was chosen as an important type of beam–column joints. The extended-end-plate connection is chosen for its complexity in the analysis and behavior due to the number of connection components and their inheritable non-linear behavior. Two experimental tests in the literature were chosen to verify the finite element model. The results of both the experimental and the proposed finite element were compared. One of these tests was monotonically loaded, whereas the second was cyclically loaded. The finite element model is improved to enhance the defects of the finite element model used. These defects are; the long time need for the analysis and the inability of the contact element type to follow the behavior of moment–rotation curve under cyclic loading. As a contact element, the surface-to-surface element is used instead of node-to-node element to enhance the model. The FE results show good correlation with the experimental one. An attempt to improve a new technique for modeling bolts is conducted. The results show that this technique is supposed to avoid the defects above, give much less elements number and less solution time than the other modeling techniques.

  2. 1991 comparative analysis of tritium in water

    International Nuclear Information System (INIS)

    Krause, W.J.; Mundschenk, H.

    1992-06-01

    For environmental monitoring of radioactive materials, the competent authorities of the States and Federal Government of Germany continuously perform measurements and make their results accessible to the public in an appropriate way. In order to guarantee the comparability of measured values and a high degree of reliability of the applied methods, the authorities in charge of carrying out such tasks are obliged to take part in the comparative analyses (ring tests) organized by the central offices of the Federal Government. Therefore, the aim of this comparative analysis performed by order of the Federal Ministry of the Environment, Nature Protection and Reactor Safety consists mainly in providing the measuring offices in charge of monitoring waters, with samples with known tritium contents in order to get an overview of the accuracy of currently used processes; check the accuracy of the determinations performed, and, if necessary, detect and eliminate systematic errors; check, in particular by means of the samples T2 and T3, the calibration of the measuring devices and, if necessary, make corrections. To this effect, the comparative analysis fulfills the function of quality control of the processes used in environmental monitoring. (orig./BBR) [de

  3. p-adic analysis compared with real

    CERN Document Server

    Katok, Svetlana

    2007-01-01

    The book gives an introduction to p-adic numbers from the point of view of number theory, topology, and analysis. Compared to other books on the subject, its novelty is both a particularly balanced approach to these three points of view and an emphasis on topics accessible to undergraduates. In addition, several topics from real analysis and elementary topology which are not usually covered in undergraduate courses (totally disconnected spaces and Cantor sets, points of discontinuity of maps and the Baire Category Theorem, surjectivity of isometries of compact metric spaces) are also included in the book. They will enhance the reader's understanding of real analysis and intertwine the real and p-adic contexts of the book. The book is based on an advanced undergraduate course given by the author. The choice of the topic was motivated by the internal beauty of the subject of p-adic analysis, an unusual one in the undergraduate curriculum, and abundant opportunities to compare it with its much more familiar real...

  4. Comparing the NIOSH Method 5040 to a Diesel Particulate Matter Meter for Elemental Carbon

    Science.gov (United States)

    Ayers, David Matthew

    Introduction: The sampling of elemental carbon has been associated with monitoring exposures in the trucking and mining industries. Recently, in the field of engineered nanomaterials, single wall and muti-wall carbon nanotubes (MWCNTs) are being produced in ever increasing quantities. The only approved atmospheric sampling for multi-wall carbon nanotubes in NIOSH Method 5040. These results are accurate but can take up to 30 days for sample results to be received. Objectives: Compare the results of elemental carbon sampling from the NIOSH Method 5040 to a Diesel Particulate Matter (DPM) Meter. Methods: MWCNTs were transferred and weighed between several trays placed on a scale. The NIOSH Method 5040 and DPM sampling train was hung 6 inches above the receiving tray. The transferring and weighing of the MWCNTs created an aerosol containing elemental carbon. Twenty-one total samples using both meters type were collected. Results: The assumptions for a Two-Way ANOVA were violated therefore, Mann-Whitney U Tests and a Kruskal-Wallis Test were performed. The hypotheses for both research questions were rejected. There was a significant difference in the EC concentrations obtained by the NIOSH Method 5040 and the DPM meter. There were also significant differences in elemental carbon level concentrations when sampled using a DPM meter versus a sampling pump based upon the three concentration levels (low, medium and high). Conclusions: The differences in the EC concentrations were statistically significant therefore, the two methods (NIOSH Method 5040 and DPM) are not the same. The NIOSH Method 5040 should continue to be the only authorized method of establishing an EC concentration for MWCNTs until a MWCNT specific method or an instantaneous meter is invented.

  5. The digital storytelling process: A comparative analysis from various experts

    Science.gov (United States)

    Hussain, Hashiroh; Shiratuddin, Norshuhada

    2016-08-01

    Digital Storytelling (DST) is a method of delivering information to the audience. It combines narrative and digital media content infused with the multimedia elements. In order for the educators (i.e the designers) to create a compelling digital story, there are sets of processes introduced by experts. Nevertheless, the experts suggest varieties of processes to guide them; of which some are redundant. The main aim of this study is to propose a single guide process for the creation of DST. A comparative analysis is employed where ten DST models from various experts are analysed. The process can also be implemented in other multimedia materials that used the concept of DST.

  6. In-vivo elemental analysis at Birmingham 1968-1981

    International Nuclear Information System (INIS)

    Chettle, D.R.; Scott, M.C.

    1986-01-01

    Techniques have been developed to measure a number of elements in-vivo. Some have been measured by producing a radioactive isotope in the body by neutron bombardment and subsequently counting γ-rays given off during its decay. Measurements of calcium and sodium have been those most frequently used; copper, iron and phosphorus have also been measured in this way. Gamma-rays emitted 10 -18 s-10 -12 s following neutron capture have also been used for elemental analysis. This method, which involved detectors being in position by the subject during the neutron irradiation, has been widely applied to measurements of both nitrogen and cadmium. Preliminary studies of nuclear resonance scattering have suggested that this could be used for in-vivo elemental analysis, provided technical difficulties in source preparation could be overcome. Recently the use of X-ray fluorescence has been investigated for in-vivo analyses of lead in bone; the extension of this technique to measure mercury in the kidney is under consideration. (author)

  7. Optimization of deformation monitoring networks using finite element strain analysis

    Science.gov (United States)

    Alizadeh-Khameneh, M. Amin; Eshagh, Mehdi; Jensen, Anna B. O.

    2018-04-01

    An optimal design of a geodetic network can fulfill the requested precision and reliability of the network, and decrease the expenses of its execution by removing unnecessary observations. The role of an optimal design is highlighted in deformation monitoring network due to the repeatability of these networks. The core design problem is how to define precision and reliability criteria. This paper proposes a solution, where the precision criterion is defined based on the precision of deformation parameters, i. e. precision of strain and differential rotations. A strain analysis can be performed to obtain some information about the possible deformation of a deformable object. In this study, we split an area into a number of three-dimensional finite elements with the help of the Delaunay triangulation and performed the strain analysis on each element. According to the obtained precision of deformation parameters in each element, the precision criterion of displacement detection at each network point is then determined. The developed criterion is implemented to optimize the observations from the Global Positioning System (GPS) in Skåne monitoring network in Sweden. The network was established in 1989 and straddled the Tornquist zone, which is one of the most active faults in southern Sweden. The numerical results show that 17 out of all 21 possible GPS baseline observations are sufficient to detect minimum 3 mm displacement at each network point.

  8. Simultaneous speciation neutron activation analysis for trace elements

    International Nuclear Information System (INIS)

    Chatt, A.; Kiceniuk, J.W.; Menendez Sanchez, W.; Bottaro, C.

    2006-01-01

    Among the various forms of neutron activation technique being developed in our laboratory, much emphasis has been placed over the last ten years or so on the development of simultaneous speciation neutron activation analysis (SSNAA). This technique can now be used for the simultaneous determination of various species of a number of elements. Almost all speciation techniques consist of two steps. The first step involves the separation of species from the sample followed by the second step of element-specific detection. A number of characteristic features of NAA, which other techniques normally do not possess, can be advantageously exploited in SSNAA. For example, SSNAA can be used for: (i) multielement speciation with high specificity, (ii) speciation of chemically dissimilar elements such as Cd, Mn and Se, (iii) speciation of elements such as Cl, Br and I which are rather difficult to determine by most other techniques, etc. We have developed SSNAA methods for assaying various arsenic species, namely As(III), As(V), dimethyl arsonic acid (DMA), monomethylarsinic acid (MMA), arsenobetaine (AsB), organically bound arsenic (OBAs), and lipid-soluble arsenic (LSAs) in marine fish samples. We have extended these methods to include simultaneous determination of various species of As, Sb and Se in water. We have also developed SSNAA methods employing biochemical techniques for the simultaneous separation, preconcentration and characterization of metalloproteins and protein-bound trace element species of As, Br, Cd, Cu, Mn, Se, and Zn. We have developed methods for the simultaneous separation and characterization of organohalogen compounds in fish. An overview of the SSNAA methods being developed in our laboratory will be presented. (author)

  9. Comparative Analysis of VERA Depletion Problems

    International Nuclear Information System (INIS)

    Park, Jinsu; Kim, Wonkyeong; Choi, Sooyoung; Lee, Hyunsuk; Lee, Deokjung

    2016-01-01

    Each code has its own solver for depletion, which can produce different depletion calculation results. In order to produce reference solutions for depletion calculation comparison, sensitivity studies should be preceded for each depletion solver. The sensitivity tests for burnup interval, number of depletion zones, and recoverable energy per fission (Q-value) were performed in this paper. For the comparison of depletion calculation results, usually the multiplication factors are compared as a function of burnup. In this study, new comparison methods have been introduced by using the number density of isotope or element, and a cumulative flux instead of burnup. In this paper, optimum depletion calculation options are determined through the sensitivity study of the burnup intervals and the number of depletion intrazones. Because the depletion using CRAM solver performs well for large burnup intervals, smaller number of burnup steps can be used to produce converged solutions. It was noted that the depletion intra-zone sensitivity is only pin-type dependent. The 1 and 10 depletion intra-zones for the normal UO2 pin and gadolinia rod, respectively, are required to obtain the reference solutions. When the optimized depletion calculation options are used, the differences of Q-values are found to be a main cause of the differences of solutions. In this paper, new comparison methods were introduced for consistent code-to-code comparisons even when different kappa libraries were used in the depletion calculations

  10. Elemental analysis of river sediments by PIXE and PIGE

    International Nuclear Information System (INIS)

    Kennedy, V.J.; Augusthy, A.; Varier, K.M.; Magudapathy, P.; Panchapakesan, S.; Nair, K.G.M.; Vijayan, V.

    1999-01-01

    The Chaliyar river, located in Kerala, India has shown preoccupying pollution levels, that constitute a threat to public health and the ecological system. PIXE and PIGE techniques have been employed to measure the elemental concentrations in the river sediment samples. Thick targets were prepared out of the sediment samples collected from various sites along the course of the river. The measurements were carried out using 3 MeV proton beam obtained from 3 MV Tandem pelletron accelerator at Institute of Physics, Bhubaneswar. The elemental concentrations, especially that of heavy metals, at different sites are discussed in detail. Our results show that sediments from a site where the industrial activities are high are significantly high in concentrations of heavy metals (Cr, Ni, Cu, Zn, Hg and Pb) than those collected from non-industrial sites. The measured values are compared with the average composition of unpolluted river sediments and other national and international river sediments. (author)

  11. Determination of trace elements in wool fibre by instrumental neutron activation analysis and relation between trace element contents and quality of wool

    International Nuclear Information System (INIS)

    Eozyol, H.

    1990-01-01

    Wool samples were analyzed by neutron activation analysis and 17 elements, Al, Ag, Au, As, Br, Ca, Co, Cr, Cu, Fe, La, Mg, Mn, Na, Sb, Se and Zn were measured quantitatively. The presence of seven others, Ce, Eu, I, Mo, Te and W was noted. Since several elements, such as Cd, Hg and Pb could not be conveniently determined by NAA, Atomic Absorption Spectroscopy (AAS) was used instead. Cu and Zn were also analyzed by NAA and AAS to compare these two methods. Mechanical properties of samples were measured and the relations between the trace element contents and properties were investigated. (author) 16 refs.; 7 tabs

  12. Structural optimisation of cage induction motors using finite element analysis

    Science.gov (United States)

    Palko, S.

    The current trend in motor design is to have highly efficient, low noise, low cost, and modular motors with a high power factor. High torque motors are useful in applications like servo motors, lifts, cranes, and rolling mills. This report contains a detailed review of different optimization methods applicable in various design problems. Special attention is given to the performance of different methods, when they are used with finite element analysis (FEA) as an objective function, and accuracy problems arising from the numerical simulations. Also an effective method for designing high starting torque and high efficiency motors is presented. The method described in this work utilizes FEA combined with algorithms for the optimization of the slot geometry. The optimization algorithm modifies the position of the nodal points in the element mesh. The number of independent variables ranges from 14 to 140 in this work.

  13. Grouping and analysis of chair quality and their basic elements

    Directory of Open Access Journals (Sweden)

    Skakić Dušan

    2009-01-01

    Full Text Available Both the scientific experience and the engineering practice indicate that the decision making processes in the course of solving complex designing problems require an analysis of a great number of different construction variants. These types of decision-making processes are time consuming and do not always result in the selection of an optimal solution. That is why the methods of numerical optimization are applied in a wide range of technical sciences to assist in the selection of the best solution. The first step in solving the problem by using the Finite element method is to determine the type of chair earmarked for modeling, and to determine the dimensions of the chair elements.

  14. Elemental analysis of Kuwaiti petroleum and combustion products

    Energy Technology Data Exchange (ETDEWEB)

    Reid, J.S.; Cahill, T.A.; Gearhart, E.A.; Flocchini, R.G. (California Univ., Davis, CA (United States). Crocker Nuclear Lab.); Schweitzer, J.S.; Peterson, C.A. (Schlumberger-Doll Research Center, Ridgefield, CT (United States))

    1993-03-01

    Crude oil from eight Kuwaiti fields and aerosols generated by their combustion in the laboratory have been analyzed by composition and particulate size. Liquid petroleum and petroleum combustion products were subjected to elemental analysis by proton induced x-ray techniques and by x-ray fluorescence techniques. The mean sulfur content of the burning wells was weighted by their production rates to obtain the mean sulfur content of the burning oil, 2.66%. The liquid samples were also analyzed by neutron activation analyses. Results show that Kuwaiti oil and smoke aerosols from laboratory combustion generally contain very low amounts of chlorine, contrary to what is found in airborne samples above Kuwait. Trace element signatures were developed to aid in tracing smoke from the oil fires. (Author).

  15. Study on Tourist Carrying Capacity Based on Matter Element Analysis

    Institute of Scientific and Technical Information of China (English)

    LiuYunguo; FanTing; LiXin; ZhouMing; WangXianhai

    2005-01-01

    This paper proposes that it is necessary to implement the concept of tourist carrying capacity to facilitate the tourism planning, and presents a method to evaluate the carrying capacity. The method called matter element analysis can solve the uncertain and incompatible problem of the evaluated factors in assessing carrying capacity.The current state of a destination's carrying capacity can be determined by establishing the standard indexes and the matter element model. Through the evaluating of the travel industry zones of the Autonomous Prefecture of Western Hunan, the method is proved to be simple and feasible, and it is improved to be significant for the tourism planning and determination as well as the sustainable development of the regional tourism.

  16. Probabilistic finite elements for fatigue and fracture analysis

    Science.gov (United States)

    Belytschko, Ted; Liu, Wing Kam

    1993-04-01

    An overview of the probabilistic finite element method (PFEM) developed by the authors and their colleagues in recent years is presented. The primary focus is placed on the development of PFEM for both structural mechanics problems and fracture mechanics problems. The perturbation techniques are used as major tools for the analytical derivation. The following topics are covered: (1) representation and discretization of random fields; (2) development of PFEM for the general linear transient problem and nonlinear elasticity using Hu-Washizu variational principle; (3) computational aspects; (4) discussions of the application of PFEM to the reliability analysis of both brittle fracture and fatigue; and (5) a stochastic computational tool based on stochastic boundary element (SBEM). Results are obtained for the reliability index and corresponding probability of failure for: (1) fatigue crack growth; (2) defect geometry; (3) fatigue parameters; and (4) applied loads. These results show that initial defect is a critical parameter.

  17. Nonlinear dynamic analysis using Petrov-Galerkin natural element method

    International Nuclear Information System (INIS)

    Lee, Hong Woo; Cho, Jin Rae

    2004-01-01

    According to our previous study, it is confirmed that the Petrov-Galerkin Natural Element Method (PG-NEM) completely resolves the numerical integration inaccuracy in the conventional Bubnov-Galerkin Natural Element Method (BG-NEM). This paper is an extension of PG-NEM to two-dimensional nonlinear dynamic problem. For the analysis, a constant average acceleration method and a linearized total Lagrangian formulation is introduced with the PG-NEM. At every time step, the grid points are updated and the shape functions are reproduced from the relocated nodal distribution. This process enables the PG-NEM to provide more accurate and robust approximations. The representative numerical experiments performed by the test Fortran program, and the numerical results confirmed that the PG-NEM effectively and accurately approximates the nonlinear dynamic problem

  18. The use of reference materials in the elemental analysis of biological samples

    International Nuclear Information System (INIS)

    Bowen, H.J.M.

    1975-01-01

    Reference materials (RMs) are useful to compare the accuracy and precision of laboratories and techniques. The desirable properties of biological reference materials are listed, and the problems of production, homogenization and storage described. At present there are only 10 biological RMs available compared with 213 geological and 520 metallurgical RMs. There is a need for more biological RMs including special materials for microprobe analysis and for in vivo activation analysis. A study of 650 mean values for elements in RM Kale, analysed by many laboratories, leads to the following conclusions. 61% of the values lie within +-10% of the best mean, and 80% lie within +-20% of the best mean. Atomic absorption spectrometry gives results that are 5-30% high for seven elements, while intrumental neutron activation analysis gives low and imprecise results for K. Other techniques with poor interlaboratory precision include neutron activation for Mg, polarography for Zn and arc-spectrometry for many elements. More than half the values for elements in Kale were obtained by neutron activation, confirming the importance of this technique and the need for RMs. As a rough estimate, 6 x 10 9 elemental analyses of biological materials are carried out each year, mostly by medical, agricultural and food scientists. It seems likely that a substantial percentage of these are inaccurate, a situation that might be improved by quality control using standard RMs. (author)

  19. Liquid phase microextraction for the analysis of trace elements and their speciation

    International Nuclear Information System (INIS)

    Hu, Bin; He, Man; Chen, Beibei; Xia, Linbo

    2013-01-01

    Trace/ultra-trace elements and their speciation analysis in complex matrices usually require sample preparation procedures to achieve sample clean-up and analyte preconcentration. Sample preparation is often the bottleneck in trace elements and their speciation analysis which has a direct impact on accuracy, precision and limits of detection and is often the rate-determining step of the analytical process. Recent trends in sample preparation include miniaturization, automation, high-throughput performance and reduction in solvent/sample consumption and operation time. Liquid-phase microextraction (LPME) technique as a novel and promising alternative in sample preparation can meet these requirements and has become a very efficient sample preparation technique. This review updates the state of art of LPME for trace elements and their speciation analysis and discusses its promising prospects. The major thrust of the article highlights the applications of LPME including single-drop microextraction (SDME), hollow fiber-liquid phase microextraction (HF-LPME), dispersive liquid liquid microextraction (DLLME) and solidified floating organic drop microextraction (SFODME) to the fields of elemental and their speciation analysis by atomic spectrometry-based methods, especially inductively coupled plasma mass spectrometry. General and specific concepts, different extraction formats and characteristics of LPME are described and compared, along with examples of recent innovations and applications presented to demonstrate its potential for trace elements and their speciation analysis in biological and environmental fields. Moreover, the application potential and an outlook on the combination of LPME and atomic spectrometry-based techniques for inorganic analysis are commentated. - Highlights: • The state of art of LPME for trace elements and their speciation analysis is updated. • Different extraction formats of LPME are described. • The application potential and future

  20. Comparative Genome Analysis of Enterobacter cloacae

    Science.gov (United States)

    Liu, Wing-Yee; Wong, Chi-Fat; Chung, Karl Ming-Kar; Jiang, Jing-Wei; Leung, Frederick Chi-Ching

    2013-01-01

    The Enterobacter cloacae species includes an extremely diverse group of bacteria that are associated with plants, soil and humans. Publication of the complete genome sequence of the plant growth-promoting endophytic E. cloacae subsp. cloacae ENHKU01 provided an opportunity to perform the first comparative genome analysis between strains of this dynamic species. Examination of the pan-genome of E. cloacae showed that the conserved core genome retains the general physiological and survival genes of the species, while genomic factors in plasmids and variable regions determine the virulence of the human pathogenic E. cloacae strain; additionally, the diversity of fimbriae contributes to variation in colonization and host determination of different E. cloacae strains. Comparative genome analysis further illustrated that E. cloacae strains possess multiple mechanisms for antagonistic action against other microorganisms, which involve the production of siderophores and various antimicrobial compounds, such as bacteriocins, chitinases and antibiotic resistance proteins. The presence of Type VI secretion systems is expected to provide further fitness advantages for E. cloacae in microbial competition, thus allowing it to survive in different environments. Competition assays were performed to support our observations in genomic analysis, where E. cloacae subsp. cloacae ENHKU01 demonstrated antagonistic activities against a wide range of plant pathogenic fungal and bacterial species. PMID:24069314

  1. A comparative study of finite element methodologies for the prediction of torsional response of bladed rotors

    International Nuclear Information System (INIS)

    Scheepers, R.; Heyns, P. S.

    2016-01-01

    The prevention of torsional vibration-induced fatigue damage to turbo-generators requires determining natural frequencies by either field testing or mathematical modelling. Torsional excitation methods, measurement techniques and mathematical modelling are active fields of research. However, these aspects are mostly considered in isolation and often without experimental verification. The objective of this work is to compare one dimensional (1D), full three dimensional (3D) and 3D cyclic symmetric (3DCS) Finite element (FE) methodologies for torsional vibration response. Results are compared to experimental results for a small-scale test rotor. It is concluded that 3D approaches are feasible given the current computing technology and require less simplification with potentially increased accuracy. Accuracy of 1D models may be reduced due to simplifications but faster solution times are obtained. For high levels of accuracy model updating using field test results is recommended

  2. Determination of elements in cisadane river sediments by neutron activation analysis

    International Nuclear Information System (INIS)

    Kamarz, H.

    1997-01-01

    Determination of elements in Cisadane river sediments by neutron activation analysis has been conducted. Samples of sediments were obtained from some location along Cisadane river, i.e. Leuranji, Karanggan, Cibigo, Cisauk, Warung Mangga Pintu Air and Estuary Teluk Naga. the elements analysed were Al, Mn, Mg, V, K, Na, Fe, Cr, Co, U and Zn, and the results were compared to the SRM of sediment sample from IAEA. Generally, the results showed that the mean concentration of elements were found in Cibogo, Cisauk, Pintu Air and Muara Teluk Naga which were higher than others. Concentration factor of elements in sediments were in between of 0,02 - 3,45, this factor indicated that Cisadane river sediments have not been contaminated. CRM sediments 2704 from IAEA used as NAA Quality Control (author)

  3. Application of ADINA fluid element for transient response analysis of fluid-structure system

    International Nuclear Information System (INIS)

    Sakurai, Y.; Kodama, T.; Shiraishi, T.

    1985-01-01

    Pressure propagation and Fluid-Structure Interaction (FSI) in 3D space were simulated by general purpose finite element program ADINA using the displacement-based fluid element which presumes inviscid and compressible fluid with no net flow. Numerical transient solution was compared with the measured data of an FSI experiment and was found to fairly agree with the measured. In the next step, post analysis was conducted for a blowdown experiment performed with a 1/7 scaled reactor pressure vessel and a flexible core barrel and the code performance was found to be satisfactory. It is concluded that the transient response of the core internal structure of a PWR during the initial stage of LOCA can be analyzed by the displacement-based finite fluid element and the structural element. (orig.)

  4. Neutron activation analysis of essential elements in Multani mitti clay using miniature neutron source reactor

    International Nuclear Information System (INIS)

    Waheed, S.; Rahman, S.; Faiz, Y.; Siddique, N.

    2012-01-01

    Multani mitti clay was studied for 19 essential and other elements. Four different radio-assay schemes were adopted for instrumental neutron activation analysis (INAA) using miniature neutron source reactor. The estimated weekly intakes of Cr and Fe are high for men, women, pregnant and lactating women and children while intake of Co is higher in adult categories and Mn by pregnant women. Comparison of MM clay with other type of clays shows that it is a good source of essential elements. - Highlights: ► Multani mitti clay has been studied for 19 essential elements for human adequacy and safety using INAA and AAS. ► Weekly intakes for different consumer categories have been calculated and compared with DRIs. ► Comparison of MM with other type of clays depict that MM clay is a good source of essential elements.

  5. Development Of The Computer Code For Comparative Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Purwadi, Mohammad Dhandhang

    2001-01-01

    The qualitative and quantitative chemical analysis with Neutron Activation Analysis (NAA) is an importance utilization of a nuclear research reactor, and this should be accelerated and promoted in application and its development to raise the utilization of the reactor. The application of Comparative NAA technique in GA Siwabessy Multi Purpose Reactor (RSG-GAS) needs special (not commercially available yet) soft wares for analyzing the spectrum of multiple elements in the analysis at once. The application carried out using a single spectrum software analyzer, and comparing each result manually. This method really degrades the quality of the analysis significantly. To solve the problem, a computer code was designed and developed for comparative NAA. Spectrum analysis in the code is carried out using a non-linear fitting method. Before the spectrum analyzed, it was passed to the numerical filter which improves the signal to noise ratio to do the deconvolution operation. The software was developed using the G language and named as PASAN-K The testing result of the developed software was benchmark with the IAEA spectrum and well operated with less than 10 % deviation

  6. Greenfields and acquisitions: a comparative analysis

    Directory of Open Access Journals (Sweden)

    Nicolae MARINESCU

    2016-07-01

    Full Text Available This paper compares greenfields and acquisitions as foreign direct investment (FDI alternatives used by transnational corporations (TNCs. First, the determinants leading to the choice of companies between the two modes of entry into a foreign market are laid out. Then, specific features of each alternative are highlighted, by contrasting the advantages and disadvantages of both types of FDI. Based on this analysis, some conclusions are drawn in the end concerning the most important factors that influence the decision of a company whether to choose a greenfield investment or an acquisition.

  7. Comparative analysis of proliferation resistance assessment methodologies

    International Nuclear Information System (INIS)

    Takaki, Naoyuki; Kikuchi, Masahiro; Inoue, Naoko; Osabe, Takeshi

    2005-01-01

    Comparative analysis of the methodologies was performed based on the discussions in the international workshop on 'Assessment Methodology of Proliferation Resistance for Future Nuclear Energy Systems' held in Tokyo, on March 2005. Through the workshop and succeeding considerations, it is clarified that the proliferation resistance assessment methodologies are affected by the broader nuclear options being pursued and also by the political situations of the state. Even the definition of proliferation resistance, despite the commonality of fundamental issues, derives from perceived threat and implementation circumstances inherent to the larger programs. Deep recognitions of the 'difference' among communities would help us to make further essential and progressed discussion with harmonization. (author)

  8. Proton induced X-Ray fluorescence study as a tool trace element analysis

    International Nuclear Information System (INIS)

    El-Kady, Ahmed A.

    1978-01-01

    Usefulness and limitations of trace elemental analysis by high energy charged particles and photon induced X-ray have been discussed. Comparison with the well established neutron activation analysis technique is also given. Back-ground radiation due to bremsstrahlung from secondary electrons and due to charged particle bremsstrahlung have been reviewed for different projectiles. The sensitivity of elemental analysis by proton induced X-ray fluorescence have been examined by measuring the characteristic X-ray emission cross section for K and L transitions of many elements and for different proton energies and compared with theroretical values. The discussion given in this report show that with suitable proton generator and a high resolution X-ray detector, proton X-ray fluorescence technique is capable of analyzing many elements simultaneously at the part per million level and offers a rapid and reliable method for trace element analysis. Data on water, blood and tissue samples given in this report are few examples of many possible applications

  9. Ultrasonic Nebulizer Assisted LIBS: a Promising Metal Elements Detection Method for Aqueous Sample Analysis

    International Nuclear Information System (INIS)

    Zhong Shilei; Zheng Ronger; Lu Yuan; Cheng Kai; Xiu Junshan

    2015-01-01

    A newly developed approach for trace metal elements detection for aqueous samples analysis is presented in this paper. The idea of this approach is to improve ablation efficiency by transforming the liquid sample into a dense cloud of droplets using an ultrasonic nebulizer. The resulting droplets are then subjected to analysis by laser induced breakdown spectroscopy (LIBS). A purpose-built ultrasonic nebulizer assisted LIBS (UN-LIBS) system has been applied to the analysis of aqueous samples at trace levels of concentration. Experimental investigations of solution samples were carried out with various dissolved trace metal elements (Mn, Zn, Cu, Pb, Fe, Mg and Na) using this approach. The characteristics of UN-LIBS signal of the elements were investigated regarding the lifetime and S/B ratio and the calibration curves for trace metal elements analyses. The obtained LODs are comparable or much better than the LODS of the reported signal enhancement approaches when the laser pulse energy was as low as 30 mJ. The good linearity of calibration curves and the low LODs shows the potential ability of this method for metal elements analysis application. The density of the electrons was calculated by measuring the Stark width of the line of H α . The possible mechanism of the LIBS signal enhancement of this approach was briefly discussed. (paper)

  10. Elemental analysis of the frontal lobe of 'normal' brain tissue and that affected by Alzheimer's disease

    International Nuclear Information System (INIS)

    Stedman, J.D.; Spyrou, N.M.

    1997-01-01

    'Normal' brain tissue and brain tissue affected by Alzheimer's disease has been taken from the frontal lobe of both hemispheres and their elemental compositions in terms of major, minor and trace elements compared. Brain samples were obtained from the MRC Alzheimer's Disease Brain Bank, London. 25 samples were taken from 18 individuals (5 males and 13 females) of mean age 79.9 ± 7.3 years with pathologically confirmed Alzheimer's disease and 26 samples from 15 individuals (8 males and 7 females) of mean age 71.8 ± 13.0 years with no pathological sings of Alzheimer's disease ('normals'). The elemental concentration of the samples were determined by the techniques of Rutherford backscattering (RBS) analysis, particle induced X-ray emission (PIXE) analysis and instrumental neutron activation analysis (INAA). Na, Mg, Al, Cl, K, Sc, Fe, Zn, Se, Br, Rb and Cs were detected by INAA and significant differences in concentrations were found between concentrations in normal and Alzheimer tissue for the elements. Na, Cl, K, Se, Br and Rb, P, S, Cl, K, Ca, Fe, Zn and Cd were detected by PIXE analysis and significant differences found for the elements P, S, Cl, K and Ca. (author)

  11. Storage and pre-neutron-activation-analysis treatment for trace-element analysis in urine

    International Nuclear Information System (INIS)

    Blotcky, A.J.; Rack, E.P.

    1985-01-01

    The problems regarding storage and pre-neutron-activation-analysis treatment for the elements aluminum, calcium, vanadium, selenium, copper, iodine, zinc, manganese, and magnesium in a urine matrix are reviewed. The type of collection and storage procedure and pre-neutron activation analysis treatment of urine depend on the specific trace element; that is, its inherent physical and chemical properties. Specifically polyethylene in teflon containers are the most suitable for general determinations. Whether any preservative is added would depend upon the stability of the trace element and its tendency for surface adsorption. Preferably, preservatives should contain no radioactivatable elements for maximum efficacy. Freeze drying or packing urine shipments under dry ice needs to be explored on an individual basis. Each pre- or post-neutron activation analysis treatment is specific and optimized for the trace element analyzed

  12. Strength Analysis on Ship Ladder Using Finite Element Method

    Science.gov (United States)

    Budianto; Wahyudi, M. T.; Dinata, U.; Ruddianto; Eko P., M. M.

    2018-01-01

    In designing the ship’s structure, it should refer to the rules in accordance with applicable classification standards. In this case, designing Ladder (Staircase) on a Ferry Ship which is set up, it must be reviewed based on the loads during ship operations, either during sailing or at port operations. The classification rules in ship design refer to the calculation of the structure components described in Classification calculation method and can be analysed using the Finite Element Method. Classification Regulations used in the design of Ferry Ships used BKI (Bureau of Classification Indonesia). So the rules for the provision of material composition in the mechanical properties of the material should refer to the classification of the used vessel. The analysis in this structure used program structure packages based on Finite Element Method. By using structural analysis on Ladder (Ladder), it obtained strength and simulation structure that can withstand load 140 kg both in static condition, dynamic, and impact. Therefore, the result of the analysis included values of safety factors in the ship is to keep the structure safe but the strength of the structure is not excessive.

  13. Distributed Finite Element Analysis Using a Transputer Network

    Science.gov (United States)

    Watson, James; Favenesi, James; Danial, Albert; Tombrello, Joseph; Yang, Dabby; Reynolds, Brian; Turrentine, Ronald; Shephard, Mark; Baehmann, Peggy

    1989-01-01

    The principal objective of this research effort was to demonstrate the extraordinarily cost effective acceleration of finite element structural analysis problems using a transputer-based parallel processing network. This objective was accomplished in the form of a commercially viable parallel processing workstation. The workstation is a desktop size, low-maintenance computing unit capable of supercomputer performance yet costs two orders of magnitude less. To achieve the principal research objective, a transputer based structural analysis workstation termed XPFEM was implemented with linear static structural analysis capabilities resembling commercially available NASTRAN. Finite element model files, generated using the on-line preprocessing module or external preprocessing packages, are downloaded to a network of 32 transputers for accelerated solution. The system currently executes at about one third Cray X-MP24 speed but additional acceleration appears likely. For the NASA selected demonstration problem of a Space Shuttle main engine turbine blade model with about 1500 nodes and 4500 independent degrees of freedom, the Cray X-MP24 required 23.9 seconds to obtain a solution while the transputer network, operated from an IBM PC-AT compatible host computer, required 71.7 seconds. Consequently, the $80,000 transputer network demonstrated a cost-performance ratio about 60 times better than the $15,000,000 Cray X-MP24 system.

  14. Finite-element pre-analysis for pressurized thermoshock tests

    International Nuclear Information System (INIS)

    Keinaenen, H.; Talja, H.; Lehtonen, M.; Rintamaa, R.; Bljumin, A.; Timofeev, B.

    1992-05-01

    The behaviour of a model pressure vessel is studied in a pressurized thermal shock loading. The tests were performed at the Prometey Institute in St. Petersburg. The calculations were performed at the Technical Research Centre of Finland. The report describes the preliminary finite-element analyses for the fourth, fifth and sixth thermoshock tests with the first model pressure vessel. Seven pressurized thermoshock tests were made with the same model using five different flaw geometries. In the first three tests the flaw was actually a blunt notch. In the two following tests (tests 4 and 5) a sharp pre-crack was produced before the test. In the last two test (tests 6 and 7) the old crack was used. According to the measurements and post-test ultrasonic examination of the crack front, the sixth test led to significant crack extension. Both temperatures and stresses were calculated using the finite-element method. The calculations were made using the idealized initial flaw geometry and preliminary material data. Both two-and three-dimensional models were used in the calculations. J-integral values were calculated from the elastic-plastic finite-element results. The stress intensity factor values were evaluated on the basis of the calculated J-integrals and compared with the preliminary material fracture toughness data obtained from the Prometey Institute

  15. Thermal analysis of cracked bodies using finite element techniques

    International Nuclear Information System (INIS)

    Hellen, T.K.; Price, R.H.; Harrison, R.P.

    1975-01-01

    The paper develops the potential energy equation in terms of finite element theory including thermal loads. Following this, the energy release rate and consequently the stress intensity factors are derived. Considerations of the classical near crack tip equations are made and deficiencies with the popular substitution methods are highlighted. A method of removing these deficiencies is described. Various energy methods are reconsidered in terms of the role of the thermal energy contribution to the potential energy. These methods include work of crack closure, energy compliance and virtual crack extensions with no other change in nodal geometry, and therefore only requires the recalculation of the stiffness matrices of the crack tip elements. An example of a quadratic temperature gradient parallel to the crack plane in an edge cracked plate is described. Comparisons of the various finite element methods are made and generally show good agreement. A second application compares the virtual crack extension method with an approximate analytical solution in determining stress intensity factors for a thick hollow cylinder with an axial crack for various depths through the wall thickness and for different times. Initially the cylinder is at a uniform high temperature and is then subjected to a sustained cooling shock. Analytical solutions are available for temperature and stress distributions in the uncracked pipe. The stress intensity for a shallow crack in the early stages of the transient has been determined using a superposition procedure. Comparison of the analytical and computed results shows good agreement between the methods

  16. Optimized elemental analysis of fluorescence lamp shredder waste.

    Science.gov (United States)

    Hobohm, Julia; Kuchta, Kerstin; Krüger, Oliver; van Wasen, Sebastian; Adam, Christian

    2016-01-15

    Fluorescence lamps contain considerable amounts of rare earth elements (REE). Several recycling procedures for REE recovery from spent lamps have been established. However, despite their economic importance, the respective recycling is scarce so far, with an REE recovery rate of less than 1%. A reliable analysis of REE and other relevant metals like Yttrium is crucial for a thorough and complete recovery process. This applies both to the solid matter and aqueous phase, since most of the recycling processes include wet-chemical steps. We tested seven different reagent mixtures for microwave-assisted digestion of fluorescent lamp shredder, including hydrofluoric acid, perchloric acid, and hydrogen peroxide. We determined the concentrations of 25 of the most relevant rare earth and other trace elements (Al, P, Ti, V, Cr, Fe, Ni, Cu, Ga, Ge, As, Y, Ag, Cd, Sn, Sb, La, Ce, Eu, Gd, Tb, W, Au, Hg, and Pb) in the respective dilutions. Two independent digestions, one a mixture of perchlorid/nitric/hydrofluoric acid and the other aqua regia, showed the highest concentrations of 23 of these elements, excluding only Sn and Tb. The REE concentrations in the tested lamp shredder sample (stated in g/kg) were 10.2 (Y), 12.1 (La), 7.77 (Ce), 6.91 (Eu), 1.90 (Gd), and 4.11 (Tb). Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Head of detector for multi-element analysis

    International Nuclear Information System (INIS)

    Frynta, Z.

    1983-01-01

    The detector head mounted on the scintillation counter consists of a hollow hexagonal rotary support axially arranged with the photomultiplier of the scintillation counter. In the walls of the hexagonal rotary support there are openings in which are inserted absorption filters. The mounting of the absorption filters on the rotary support allows the analysis of a greater number of elements without the dismantling of the head and the replacement of filters. The suitable geometry of the head is retained so that it is possible to insert the head into the hollows similarly as the scintillation counter. (J.P.)

  18. Neutron activation analysis of trace elements in rain water

    International Nuclear Information System (INIS)

    Luten, J.B.

    1977-01-01

    In this thesis the principles and practical aspects of activation analysis which are of direct importance in the analysis of rain water, are presented together with recent literature data on other techniques. Problems due to the storage of rain water samples are discussed. A multi-element method for the determination of trace elements in rain water by instrumental neutron activation analysis is described. Gamma ray spectrometry using Ge(Li) detectors offers the possibility to determine Na, Al, Cl, V, Mn, Co, Cu, Br and I in rain water samples of 2.5 ml after a 4-min irradiation in a thermal neutron flux of 5 x 10 13 n cm -2 s -1 . In residues of rain water samples of 100 ml, irradiated during 2 days in a thermal neutron flux of >5 x 10 13 n cm -2 s -1 Cr, Fe, Co, Zn and Sb can be determined after a cooling period of approximately 21 days. The detection limits are lower than those reported in previous investigations except for Cu. The precision is about 10% or better, except for Co, Cu and I. A routine method for the determination of bromine and iodine in rain water by n.a.a. is presented. The elements are isolated by isotope exchange between the irradiated sample and a solution of Br 2 or I 2 in CCl 4 . The method is not sensitive to the chemical species in which the halogen is present. Irradiation of solutions of iodine compounds in a high thermal neutron flux gives rise to the formation of iodate. Results of a further investigation of this phenomenon are given, as well as the determination of iodate in rain water by n.a.a. Iodate is separated by anion exchange. The combination of n.a.a. and solvent extraction is used for the determination of five trace elements (V, Co, Cu, Zn and In) in 10-ml rain water samples. For V, Co and Cu this method is more sensitive and reproducible than instrumental n.a.a. The results of the analysis of eleven sequential 30-ml samples from the beginning of the shower are presented as an illustration of possible applications of the

  19. Applications of finite-element scaling analysis in primatology.

    Science.gov (United States)

    Richtsmeier, J T

    1989-01-01

    The study of biological shape in three dimensions using landmark data can now be accomplished using several alternative methods. This report focuses on the use of finite-element scaling analysis in primate craniofacial morphology. The method is particularly useful in its ability to localize the differences between forms, thereby indicating those loci that differ most between specimens. Several examples of this feature are provided from primatological research. Particulars of the methods are also discussed in an attempt to provide the reader with cautionary knowledge for prudent application of the method in future research.

  20. Finite element analysis of reticulated ceramics under compression

    International Nuclear Information System (INIS)

    D’Angelo, Claudio; Ortona, Alberto; Colombo, Paolo

    2012-01-01

    Graphical abstract: - Abstract: This paper shows how finite element analysis can be used to study the effect of the morphological features of reticulated ceramics on their mechanical properties under compression. Quantitative morphological data, obtained by X-ray computed tomography (XCT) for a commercially available Si–SiC foam produced by the replica method, have been linked to a set of computer generated cells in which one morphological parameter was varied at a time. The findings indicate how the modification of some morphological features, which depend on the careful selection of appropriate and specific processing parameters, would enable the production of ceramic foams possessing higher strength for a given total porosity value.

  1. Eddy current analysis by the finite element circuit method

    International Nuclear Information System (INIS)

    Kameari, A.; Suzuki, Y.

    1977-01-01

    The analysis of the transient eddy current in the conductors by ''Finite Element Circuit Method'' is developed. This method can be easily applied to various geometrical shapes of thin conductors. The eddy currents on the vacuum vessel and the upper and lower support plates of JT-60 machine (which is now being constructed by Japan Atomic Energy Research Institute) are calculated by this method. The magnetic field induced by the eddy current is estimated in the domain occupied by the plasma. And the force exerted to the vacuum vessel is also estimated

  2. Preliminary analysis on the water quality index (WQI) of irradiated basic filter elements

    Science.gov (United States)

    Arif Abu Bakar, Asyraf; Muhamad Pauzi, Anas; Aziz Mohamed, Abdul; Syima Sharifuddin, Syazrin; Mohamad Idris, Faridah

    2018-01-01

    Simple water filtration system is needed in times of extreme floods. Clean water for sanitation at evacuation centres is essential and its production is possible by using the famous simple filtration system consisting of empty bottle and filter elements (sands, gravels, cotton/coffee filter). This research intends to study the effects of irradiated filter elements on the filtration effectiveness through experiments. The filter elements will be irradiated with gamma and neutron radiation using the facilities available at Malaysia Nuclear Agency. The filtration effectiveness is measured using the water quality index (WQI) that is developed in this study to reflect the quality of filtered water. The WQI of the filtered water using the system with irradiated filter elements is then compared with that of the system with non-irradiated filter elements. This preliminary analysis only focus on filtration element of silica sand. Results shows very nominal variation in in WQI after filtered by non-irradiated, gamma and neutron filter element (silica sand), where the hypothesis could not be affirmed.

  3. Comparative Analysis of 37 Acinetobacter Bacteriophages

    Directory of Open Access Journals (Sweden)

    Dann Turner

    2017-12-01

    Full Text Available Members of the genus Acinetobacter are ubiquitous in the environment and the multiple-drug resistant species A. baumannii is of significant clinical concern. This clinical relevance is currently driving research on bacterial viruses infecting A. baumannii, in an effort to implement phage therapy and phage-derived antimicrobials. Initially, a total of 42 Acinetobacter phage genome sequences were available in the international nucleotide sequence databases, corresponding to a total of 2.87 Mbp of sequence information and representing all three families of the order Caudovirales and a single member of the Leviviridae. A comparative bioinformatics analysis of 37 Acinetobacter phages revealed that they form six discrete clusters and two singletons based on genomic organisation and nucleotide sequence identity. The assignment of these phages to clusters was further supported by proteomic relationships established using OrthoMCL. The 4067 proteins encoded by the 37 phage genomes formed 737 groups and 974 orphans. Notably, over half of the proteins encoded by the Acinetobacter phages are of unknown function. The comparative analysis and clustering presented enables an updated taxonomic framing of these clades.

  4. Trace Elements in Human Myocardial Infarction Determined by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Wester, P.O.

    1965-05-01

    By means of neutron activation analysis, injured and adjacent uninjured human heart tissue from 12 autopsy cases with myocardial infarction are investigated with respect to the concentration of 23 trace elements. The bulk elements K, Na and P are also determined. A recently developed ion-exchange technique, combined with subsequent y-spectrometry, is used. The following trace elements are determined: Ag, As, Au, Ba, Br, Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Rb, Sb, Sc, Se, Sm, Zn and W. In the injured tissue compared to the uninjured, calculation on a wet weight basis showed a decrease in Co, Cs, K, Mo, P, Rb and Zn, and an increase in Br, Ca, Ce, La, Na, Sb and Sm. The differences in Ca, La, Mo, P and Zn are dependent on the age of the myocardial infarction, and the regression lines for these elements are given. The concentration of the trace elements in uninjured tissue from infarcted hearts is compared to the concentration of these elements in normal heart tissue, determined in a previous study. In the uninjured tissue from infarcted hearts a decrease is found in Cu and Mo, and an increase in As and Ce

  5. Trace Elements in Human Myocardial Infarction Determined by Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wester, P O

    1965-05-15

    By means of neutron activation analysis, injured and adjacent uninjured human heart tissue from 12 autopsy cases with myocardial infarction are investigated with respect to the concentration of 23 trace elements. The bulk elements K, Na and P are also determined. A recently developed ion-exchange technique, combined with subsequent y-spectrometry, is used. The following trace elements are determined: Ag, As, Au, Ba, Br, Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Rb, Sb, Sc, Se, Sm, Zn and W. In the injured tissue compared to the uninjured, calculation on a wet weight basis showed a decrease in Co, Cs, K, Mo, P, Rb and Zn, and an increase in Br, Ca, Ce, La, Na, Sb and Sm. The differences in Ca, La, Mo, P and Zn are dependent on the age of the myocardial infarction, and the regression lines for these elements are given. The concentration of the trace elements in uninjured tissue from infarcted hearts is compared to the concentration of these elements in normal heart tissue, determined in a previous study. In the uninjured tissue from infarcted hearts a decrease is found in Cu and Mo, and an increase in As and Ce.

  6. Investigation of trace elements in Elbe water by means of instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Motamedi, K.

    1977-01-01

    Investigations of trace elements in Elbe water were carried out as a contribution to environmental research, hydrology, and geochemistry. The method applied - instrumental neutron activation analysis - is described, and problems connected with the course of analysis - sample taking, handling and preparation as well as optimization of in-pile irradiation and measurement by means of γ spectrometry - are discussed and presented one by one. The computer programme set up for automatic evaluation is described in more detail. This programme AKAN has a very general concept which makes it applicable for general use. The reliability of the evaluation procedure - monostandard method - and the reproducibility of the results are discussed. For the studies, samples were taken at different times, every time from 8 positions along a long section of the Elbe. The content of solids was analyzed; in a number of samples, this was done by separating suspended and dissolved materials. Up to 38 elements were analyzed, whose local and time-dependent concentration curves are given. The contents of some elements are compared with the few available data from literature. Correlation calculations indicate a similar behaviour of single element groups and yield information on the natural origin of the trace elements and on anthropogenic influence to be noticed in the trace element contents. (orig.) [de

  7. Sorption of redox-sensitive elements: critical analysis

    International Nuclear Information System (INIS)

    Strickert, R.G.

    1980-12-01

    The redox-sensitive elements (Tc, U, Np, Pu) discussed in this report are of interest to nuclear waste management due to their long-lived isotopes which have a potential radiotoxic effect on man. In their lower oxidation states these elements have been shown to be highly adsorbed by geologic materials occurring under reducing conditions. Experimental research conducted in recent years, especially through the Waste Isolation Safety Assessment Program (WISAP) and Waste/Rock Interaction Technology (WRIT) program, has provided extensive information on the mechanisms of retardation. In general, ion-exchange probably plays a minor role in the sorption behavior of cations of the above three actinide elements. Formation of anionic complexes of the oxidized states with common ligands (OH - , CO -- 3 ) is expected to reduce adsorption by ion exchange further. Pertechnetate also exhibits little ion-exchange sorption by geologic media. In the reduced (IV) state, all of the elements are highly charged and it appears that they form a very insoluble compound (oxide, hydroxide, etc.) or undergo coprecipitation or are incorporated into minerals. The exact nature of the insoluble compounds and the effect of temperature, pH, pe, other chemical species, and other parameters are currently being investigated. Oxidation states other than Tc (IV,VII), U(IV,VI), Np(IV,V), and Pu(IV,V) are probably not important for the geologic repository environment expected, but should be considered especially when extreme conditions exist (radiation, temperature, etc.). Various experimental techniques such as oxidation-state analysis of tracer-level isotopes, redox potential measurement and control, pH measurement, and solid phase identification have been used to categorize the behavior of the various valence states

  8. Sorption of redox-sensitive elements: critical analysis

    Energy Technology Data Exchange (ETDEWEB)

    Strickert, R.G.

    1980-12-01

    The redox-sensitive elements (Tc, U, Np, Pu) discussed in this report are of interest to nuclear waste management due to their long-lived isotopes which have a potential radiotoxic effect on man. In their lower oxidation states these elements have been shown to be highly adsorbed by geologic materials occurring under reducing conditions. Experimental research conducted in recent years, especially through the Waste Isolation Safety Assessment Program (WISAP) and Waste/Rock Interaction Technology (WRIT) program, has provided extensive information on the mechanisms of retardation. In general, ion-exchange probably plays a minor role in the sorption behavior of cations of the above three actinide elements. Formation of anionic complexes of the oxidized states with common ligands (OH/sup -/, CO/sup - -//sub 3/) is expected to reduce adsorption by ion exchange further. Pertechnetate also exhibits little ion-exchange sorption by geologic media. In the reduced (IV) state, all of the elements are highly charged and it appears that they form a very insoluble compound (oxide, hydroxide, etc.) or undergo coprecipitation or are incorporated into minerals. The exact nature of the insoluble compounds and the effect of temperature, pH, pe, other chemical species, and other parameters are currently being investigated. Oxidation states other than Tc (IV,VII), U(IV,VI), Np(IV,V), and Pu(IV,V) are probably not important for the geologic repository environment expected, but should be considered especially when extreme conditions exist (radiation, temperature, etc.). Various experimental techniques such as oxidation-state analysis of tracer-level isotopes, redox potential measurement and control, pH measurement, and solid phase identification have been used to categorize the behavior of the various valence states.

  9. Elemental analysis of traditional medicinal seeds by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Khaled, S.; Mouzai, M.; Ararem, A.; Hamidatou, L.; Zouranen, B.

    2009-01-01

    Traditional medicinal seeds prescribed for specific treatment purposes, were purchased from local markets and analyzed by INAA. The samples were irradiated at Es-Salam research reactor, at a power of 5 MWfor 6 h. The accuracy of the method was established by analyzing reference materials. Twenty elements were measured, with good accuracy and reproducibility. The concentration of elements determined, was found to vary depending on the seeds. The daily intake of essential and toxic elements was determined, and compared with the recommended values. The probable cumulative intake of toxic elements is well below the tolerance limits. (author)

  10. Multi-element analysis, bioavailability and fractionation of herbal tea products

    International Nuclear Information System (INIS)

    Szymczycha-Madeja, Anna; Welna, Maja; Zyrnicki, Wieslaw

    2013-01-01

    Herbal teas (Mentha piperitae foliumand mixture Marticaria chamomilla flos with Lavandula officinalis flos) were compared considering the total contents of micro (Al, Ba, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Sr, Ti, V) and macro (C, H, N, S, Ca, Mg, P) elements, bioavailability and fractionation. Different methods (inductively coupled plasma optical emission spectrometry (ICP OES), Fourier transform infrared spectroscopy (FTIR) and CHNS elemental analysis) were applied. The microwave-assisted digestion procedure was found to be more effective than the hot-plate heating for the wet acid digestion of tea. The application of the modified BCR (Community Bureau of Reference) sequential extraction procedure exhibited differences in the concentrations of metal bound to reducible and oxidizable fractions. The accuracy of method was verified by analysis of certified reference material INCT-TL -1 Tea Leaves. The daily intake of all elements from the analyzed herbal tea infusion did not exceed the maximum permissible levels and does not constitute health risk. (author)

  11. Multi-element analysis, bioavailability and fractionation of herbal tea products

    Energy Technology Data Exchange (ETDEWEB)

    Szymczycha-Madeja, Anna; Welna, Maja; Zyrnicki, Wieslaw, E-mail: anna.szymczycha@pwr.wroc.pl [Wroclaw University of Technology, Chemistry Department, Analytical Chemistry Division, Wroclaw (Poland)

    2013-05-15

    Herbal teas (Mentha piperitae foliumand mixture Marticaria chamomilla flos with Lavandula officinalis flos) were compared considering the total contents of micro (Al, Ba, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Sr, Ti, V) and macro (C, H, N, S, Ca, Mg, P) elements, bioavailability and fractionation. Different methods (inductively coupled plasma optical emission spectrometry (ICP OES), Fourier transform infrared spectroscopy (FTIR) and CHNS elemental analysis) were applied. The microwave-assisted digestion procedure was found to be more effective than the hot-plate heating for the wet acid digestion of tea. The application of the modified BCR (Community Bureau of Reference) sequential extraction procedure exhibited differences in the concentrations of metal bound to reducible and oxidizable fractions. The accuracy of method was verified by analysis of certified reference material INCT-TL{sup -1} Tea Leaves. The daily intake of all elements from the analyzed herbal tea infusion did not exceed the maximum permissible levels and does not constitute health risk. (author)

  12. Comparison of elemental contents of Korean space foods using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Yong Sam Chung; Sun Ha Kim; Gwang Min Sun; Jong Myoung Lim; Jong Hwa Moon; Kye Hong Lee; Young Jin Kim; Jong Il Choi; Ju Woon Lee

    2012-01-01

    The analysis of mineral contents in space foods is needed to obtain an information on a comprehensive elemental composition as well as the investigation on the effects of human nutrition and health based on the dietary intake of mineral elements. Recently, six items of new Korean space foods (KSFs) such as kimchi, bibimbap, bulgogi, a ramen, a mulberry beverage and a fruit punch which was developed by the KAERI, and the contents of more than 15 elements in the samples were examined by using instrumental neutron activation analysis (INAA). Five biological certified reference materials, NIST SRM were used for analytical quality control. The results were compared with those of common Korean foods reported, and these results will be applied toward the identification of irradiated foods. (author)

  13. Trace elements status of pulmonary tuberculosis patients compared with healthy voluntaries

    International Nuclear Information System (INIS)

    Moraes, Milena L. de; Ramalho, Daniela M.P.; Delogo, Karina N.; Miranda, Pryscila F.C.; Mesquita, Eliene D.D.; Kritski, Afranio L.; Oliveira, Martha M.; Canellas, Catarine G.L.; Lopes, Ricardo T.; Anjos, Marcelino J.

    2011-01-01

    Trace elements have important contribution to immune function. The objective of this study was to compare the Iron, Copper and Zinc levels of patients with active Pulmonary Tuberculosis (TB) and healthy subjects using X-ray Total Reflection Fluorescence Spectrometry. The study group was formed by men with active TB hospitalized on the Ary Parreiras State Institute of diseases of the chest and on the Santa Maria State Hospital, Rio de Janeiro, Brazil. The control group was formed by healthy men of Military Academy Fire Dom Pedro II, Rio de Janeiro, Brazil. The measurements of trace elements were performed at XRF beam line at Brazilian Synchrotron Light, Campinas, Sao Paulo. The results show that serum iron concentration was higher in control group than in study group. Besides that, serum copper concentration was higher in control group than in study group. According to the literature higher levels of copper are observed in infectious diseases like tuberculosis. In the case of the serum zinc concentration no statistical difference was observed between the two groups studied. (author)

  14. Trace elements status of pulmonary tuberculosis patients compared with healthy voluntaries

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, Milena L. de; Ramalho, Daniela M.P.; Delogo, Karina N.; Miranda, Pryscila F.C.; Mesquita, Eliene D.D.; Kritski, Afranio L.; Oliveira, Martha M. [Centro de Pesquisa em Tuberculose, Hospital Universitario Clementino Fraga Filho, Universidade Federal do Rio de Janeiro, RJ (Brazil); Canellas, Catarine G.L.; Lopes, Ricardo T., E-mail: ricardo@lin.ufrj.br [Laboratorio de Instrumentacao Nuclear, Programa de Engenharia Nuclear/COPPE UFRJ, RJ (Brazil); Anjos, Marcelino J., E-mail: marcelin@uerj.br [Departamento de Fisica Aplicada e Termodinamica - Instituto de Fisica Armando Dias Tavares. Universidade do Estado do Rio de Janeiro, RJ (Brazil)

    2011-07-01

    Trace elements have important contribution to immune function. The objective of this study was to compare the Iron, Copper and Zinc levels of patients with active Pulmonary Tuberculosis (TB) and healthy subjects using X-ray Total Reflection Fluorescence Spectrometry. The study group was formed by men with active TB hospitalized on the Ary Parreiras State Institute of diseases of the chest and on the Santa Maria State Hospital, Rio de Janeiro, Brazil. The control group was formed by healthy men of Military Academy Fire Dom Pedro II, Rio de Janeiro, Brazil. The measurements of trace elements were performed at XRF beam line at Brazilian Synchrotron Light, Campinas, Sao Paulo. The results show that serum iron concentration was higher in control group than in study group. Besides that, serum copper concentration was higher in control group than in study group. According to the literature higher levels of copper are observed in infectious diseases like tuberculosis. In the case of the serum zinc concentration no statistical difference was observed between the two groups studied. (author)

  15. Multi-element analysis of unidentified fallen objects from Tatale in ...

    African Journals Online (AJOL)

    A multi-element analysis has been carried out on two fallen objects, # 01 and # 02, using instrumental neutron activation analysis technique. A total of 17 elements were identified in object # 01 while 21 elements were found in object # 02. The two major elements in object # 01 were Fe and Mg, which together constitute ...

  16. Comparative genome analysis of Basidiomycete fungi

    Energy Technology Data Exchange (ETDEWEB)

    Riley, Robert; Salamov, Asaf; Henrissat, Bernard; Nagy, Laszlo; Brown, Daren; Held, Benjamin; Baker, Scott; Blanchette, Robert; Boussau, Bastien; Doty, Sharon L.; Fagnan, Kirsten; Floudas, Dimitris; Levasseur, Anthony; Manning, Gerard; Martin, Francis; Morin, Emmanuelle; Otillar, Robert; Pisabarro, Antonio; Walton, Jonathan; Wolfe, Ken; Hibbett, David; Grigoriev, Igor

    2013-08-07

    Fungi of the phylum Basidiomycota (basidiomycetes), make up some 37percent of the described fungi, and are important in forestry, agriculture, medicine, and bioenergy. This diverse phylum includes symbionts, pathogens, and saprotrophs including the majority of wood decaying and ectomycorrhizal species. To better understand the genetic diversity of this phylum we compared the genomes of 35 basidiomycetes including 6 newly sequenced genomes. These genomes span extremes of genome size, gene number, and repeat content. Analysis of core genes reveals that some 48percent of basidiomycete proteins are unique to the phylum with nearly half of those (22percent) found in only one organism. Correlations between lifestyle and certain gene families are evident. Phylogenetic patterns of plant biomass-degrading genes in Agaricomycotina suggest a continuum rather than a dichotomy between the white rot and brown rot modes of wood decay. Based on phylogenetically-informed PCA analysis of wood decay genes, we predict that that Botryobasidium botryosum and Jaapia argillacea have properties similar to white rot species, although neither has typical ligninolytic class II fungal peroxidases (PODs). This prediction is supported by growth assays in which both fungi exhibit wood decay with white rot-like characteristics. Based on this, we suggest that the white/brown rot dichotomy may be inadequate to describe the full range of wood decaying fungi. Analysis of the rate of discovery of proteins with no or few homologs suggests the value of continued sequencing of basidiomycete fungi.

  17. Comparative study for essential elements determination in milk products samples by INAA and ICP-AES

    International Nuclear Information System (INIS)

    Kira, Carmen S.; Maihara, Vera A.

    2002-01-01

    The mineral elements Ca, Fe, K, Mg, Na and Zn were analyzed in milk products by using instrumental neutron activation analysis (INAA) and inductively coupled plasma atomic emission spectrometry (ICP-AES). The study included four types of cheese (mozzarella, minas, prato, parmesan), chocolate milk and yogurt. The samples were purchased from the local markets. Average concentrations ranged from 3668 (chocolate milk) to 16558 (parmesan cheese) mg/kg for Ca; from 2.61 (parmesan cheese) to 28.9 (chocolate milk) mg/kg for Fe; from 673 (mozzarella cheese) to 10492 (chocolate milk) mg/kg for K; from 398 (yogurt) to 2280 (minas cheese) mg/kg for Mg; from 1681 (yogurt) to 15248 (parmesan cheese) mg/kg for Na; from 12.1 (chocolate milk) to 71.8 (parmesan cheese) mg/kg for Zn. Two National Institute of Standards and Technology (NIST) standard reference materials (SRM 8435 Whole Milk Powder and SRM 1549 Non Fat Milk Powder) were analyzed to verify method accuracy. The statistic test used to determine the significance of the difference between the techniques was based on Unpaired t-Student test. Statistical test revealed no significance differences (P< 0,05) between the average values provided by the two methods for the most of determined elements. (author)

  18. Comparative genome sequencing of Drosophila pseudoobscura: Chromosomal, gene, and cis-element evolution

    DEFF Research Database (Denmark)

    Richards, Stephen; Liu, Yue; Bettencourt, Brian R.

    2005-01-01

    years (Myr) since the pseudoobscura/melanogaster divergence. Genes expressed in the testes had higher amino acid sequence divergence than the genome-wide average, consistent with the rapid evolution of sex-specific proteins. Cis-regulatory sequences are more conserved than random and nearby sequences......We have sequenced the genome of a second Drosophila species, Drosophila pseudoobscura, and compared this to the genome sequence of Drosophila melanogaster, a primary model organism. Throughout evolution the vast majority of Drosophila genes have remained on the same chromosome arm, but within each...... between the species-but the difference is slight, suggesting that the evolution of cis-regulatory elements is flexible. Overall, a pattern of repeat-mediated chromosomal rearrangement, and high coadaptation of both male genes and cis-regulatory sequences emerges as important themes of genome divergence...

  19. Analysis of TRU waste for RCRA-listed elements

    International Nuclear Information System (INIS)

    Mahan, C.; Gerth, D.; Yoshida, T.

    1996-01-01

    Analytical methods for RCRA listed elements on Portland cement type waste have been employed using both microwave and open hot plate digestions with subsequent analysis by inductively coupled plasma atomic emission spectroscopy (ICP-AES), inductively coupled plasma mass spectrometry (ICP-AES), inductively coupled plasma mass spectrometry (ICP-MS), graphite furnace atomic absorption (GFAA) and cold vapor atomic absorption and fluorescence (CVAA/CVAFS). Four different digestion procedures were evaluated including an open hot plate nitric acid digestion, EPA SW-846 Method 3051, and 2 methods using modifications to Method 3051. The open hot plate and the modified Method 3051, which used aqua regia for dissolution, were the only methods which resulted in acceptable data quality for all 14 RCRA-listed elements. Results for the nitric acid open hot plate digestion were used to qualify the analytical methods for TRU waste characterization, and resulted in a 99% passing score. Direct chemical analysis of TRU waste is being developed at Los Alamos National Laboratory in an attempt to circumvent the problems associated with strong acid digestion methods. Technology development includes laser induced breakdown spectroscopy (LIBS), laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS), dc arc CID atomic emission spectroscopy (DC-AES), and glow discharge mass spectrometry (GDMS). Analytical methods using the Portland cement matrix are currently being developed for each of the listed techniques. Upon completion of the development stage, blind samples will be distributed to each of the technology developers for RCRA metals characterization

  20. Investigation of Apple Vibration Characteristics Using Finite Element Modal Analysis

    Directory of Open Access Journals (Sweden)

    R Mirzaei

    2013-02-01

    Full Text Available The most important quality indicator of fruits is the flesh firmness which is well correlated to their young’s modulus. In this research variation of vibration characteristics (shape modes, natural frequency of apple due to change of material characteristics (density, young's models, Poisson ratio and apple volume was investigated using Finite Element simulation. An image processing technique was used to obtain an unsymmetrical and non-spherical geometric model of apple. The exact three-dimensional shape of the fruit was created by determining the coordinates of apple surface and forming uneven rotational curvatures. Modal analysis with no boundary constraints has been applied. The first 20 Eigen frequencies and the corresponding mode shape were determined. Six rigid body modes possess zero resonant frequency which is related to the degree of freedom of a rigid body in space indicated the validity of finite element model. The modal analysis results showed that resonant frequency increased by increasing young's modulus of the fruit, while it decreased by increasing apple density. First mode torsion has a mean resonant frequency of 584 Hz. Variations of natural frequency due to change in young's modulus, density, and Poisson ratio were 80%, 11% and 4%, respectively. Coefficient of variation of resonant frequency in response to changing young's modulus was 2-3 times of that of density which shows the greatest effect of young modulus changes on natural frequency of fruits. Consequently with determination of fruits' natural frequency, their young modulus and firmness can be estimated.

  1. X-ray trace element analysis with positive ion beams

    International Nuclear Information System (INIS)

    Davis, R.H.

    1973-01-01

    A new trace element analysis having the advantage that many elements may be detected in a single measurement, based on positive charged particle induced X-ray florescence and on the production of X-rays by heavy ions, is described. Because of the large cross-sections for the production of discrete X-ray and the low yield of continuum radiation, positive charged particle X-ray florescence is a competitive, fast, analytic tool. In the experiment a beam of positive charged particles from an accelerator was directed toward a target. X-rays induced by the bombardment were detected by a Si(Li) detector the ouput from which was amplified and sorted in a multichannel analyzer. For rapid data handling and analysis, the multichannel analyzer or ADC unit was connected to an on-line computer. A large variety of targets prepared in collaboration with the oceanographers have been studied and spectra obtained for different particles having the same velocity are presented to show that the yield of discrete X-rays increases at least as rapidly as Z 2 . While protons of several MeV appear to be already competitive further advantage may be gained by heavy ions at lower energies since the continuum is reduced while the peak ''signals'' retain strength due to the Z 2 dependence. (S.B.)

  2. Multi-element neutron activation analysis of Brazilian coal samples

    International Nuclear Information System (INIS)

    Atalla, L.T.; Requejo, C.S.

    1982-09-01

    The elements U, Th, La, Ce, Nd, Sm, Eu, Dy, Tb, Yb, Lu, Sc, Ta, Hf, Co, Ni, Cr, Mo, Ti, V, W, In, Ga, Mn, Ba, Sr, Mg, Rb, Cs, K, Cl, Br, As, Sb, Au, Ca, Al and Fe were determined in coal samples by instrumental neutron activation analysis, by using both thermal and epithermal neutron irradiations. The irradiation times were 10 minutes and 8 or 16 hours in a position where the thermal neutron flux was about 10 12 n.cm - 2 .s - 1 and 72 non-consecutive hours for epithermal irradiation at a flux of about 10 11 n.Cm - 2 .s - 1 . After the instrumental analysis of the above mentioned elements, Zn and Se were determined with chemical separation. The relative standard deviation of, at least, 4 determinations was about + - 10% for the majority of the results. The coal samples analysed were supplied by: Cia. Estadual da Tecnologia e Saneamento Basico (CETESB-SP), Cia. de Pesquisas e Lavras Minerais (COPELMI-RS), Cia. Carbonifera Urussunga (SC), Cia. Carbonifera Prospera (SC), Cia. Carbonifera Treviso (SC), Cia. Nacional de Mineracao de Carvao do Barro Branco (SC) and Comissao Nacional de Energia Nuclear (CNEN-RJ). (Author) [pt

  3. Finite element analysis of elasto-plastic tee joints

    International Nuclear Information System (INIS)

    Powell, G.H.

    1974-09-01

    The theory and computational procedures used in the computer program B169TJ/EP for the analysis of elasto-plastic tee joints are described, and detailed user's guide is presented. The program is particularly applicable to joints conforming to the ANSI B16.9 Manufacturing Standard, but can also be applied to other joint geometries. The joint may be loaded by internal pressure and by arbitrary combinations of applied forces and moments at the ends of the branch and run pipes, and the loading sequence may be arbitrary. The joint material is assumed to yield according to the von Mises criterion, and to exhibit either linear kinematic hardening or nonlinear isotropic hardening after yield. The program makes use of the finite element and mesh generation procedures previously applied in the elastic stress analysis program B16.9TJ/ SA, with minor modifications. (U.S.)

  4. Biomonitoring of air pollution through trace element analysis

    International Nuclear Information System (INIS)

    Akoto Bamford, Samuel; Osae, E.K.; Serfor-Armah, Y.; Nyarko, B.; Ofosu, F.; Aboh, I.J.; Odamtten, G.T.

    2001-01-01

    Research work is currently going on to determine the suitability in the use of local lichen species for biomonitoring air pollution in Ghana. The study areas being investigated are the gold-mining areas situated in the Moist Evergreen and Semi-Deciduous forests in Ghana. The nuclear analytical techniques being used in this work are instrumental neutron activation analysis and tube-excited x-ray fluorescence spectrometry. The present report covers results of quality control exercise carried out to validate the quantitative methods being used. This includes our participation in an intercomparison exercise carried out among participants of the IAEA coordinated research project. The samples analyzed were two lichen samples from two completely different areas using neutron activation analysis. Only short- and medium-lived irradiations were carried out. Satisfactory results were obtained for most of the elements identified and quantified. (author)

  5. Development of environmental education system using online element analysis

    International Nuclear Information System (INIS)

    Niizeki, T.; Yoshihara, T.; Tsuchiya, K.; Kawasaki, K.; Komiya, K.

    2007-01-01

    We have constructed a network system which enables one to access and analyze environmental data obtained at different and distant laboratories. As a preliminary feasibility test of the system, we studied the elements in the water of the Tesio River using PIXE and ion chromatography. Students used the data online to carry out analysis via internet. We found two factors with different features in calcium from the factor analysis. The comparison of the specific result and relevant geology information has revealed a remarkable presence of Ca 2+ which might come from dissolution of limestone in the upper Tesio River. PIXE data gave crucial information to draw such a conclusion. The present system has been found useful in environmental education in universities, online sharing of PIXE data in particular. (author)

  6. Automatic measurement system for light element isotope analysis

    International Nuclear Information System (INIS)

    Satake, Hiroshi; Ikegami, Kouichi.

    1990-01-01

    The automatic measurement system for the light element isotope analysis was developed by installing the specially designed inlet system which was controlled by a computer. The microcomputer system contains specific interface boards for the inlet system and the mass spectrometer, Micromass 602 E. All the components of the inlet and the computer system installed are easily available in Japan. Ten samples can be automatically measured as a maximum of. About 160 minutes are required for 10 measurements of δ 18 O values of CO 2 . Thus four samples can be measured per an hour using this system, while usually three samples for an hour using the manual operation. The automatized analysis system clearly has an advantage over the conventional method. This paper describes the details of this automated system, such as apparatuses used, the control procedure and the correction for reliable measurement. (author)

  7. Determination of trace elements in Turkish tea leaves by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Demiralp, R.

    1986-01-01

    The human body continuously assimilates a variety of inorganic elements from food and the environment. Some of these elements are closely related to human health and disorder. Tea is one of the most popular stimulating beverages which is consumed by low and high income family groups in many countries. Instrumental neutron activation analysis is one of the preferred methods because information on a large number of elements can be obtained simultaneously. Five packets each of the seven commonly used brands of tea were obtained from the market. In order to determine the transfer of trace elements into the drinkable portion about 2-3g. of the tea leaves were boiled in hot water for 2 min. After filtration the used tea leaves were dried at 65 deg. C in an oven and a portion, about 200mg was used for analysis. Samples and standards were irradiated 10 min. and 2 hrs. at pneumatic system and central thimble in the TRIGA MARK-II research reactor. After irradiation, the activities of samples and standards were measured with a aoaxial Ge detector coupled to a spectroscopic amplifier. A Canbera 90 model multi- channel analyzer with an 8K memory was used for pulse height analysis. The system has a resolution of 2.0 KeV. for the 1332.5 KeV gamma ray of 60 Co. The activity of the sample and standard was compared and the element contst of the sample was calculated. (author)

  8. Elemental analysis of Oum er Rbia Moroccan river-water using TXRF

    International Nuclear Information System (INIS)

    Zahry, F.; Bounakhla, M.; El Hamdaoui, A.; Labraimi, M.

    2000-01-01

    The x-ray fluorescence analysis of water and suspended particulate matter (SPM) from Oum er Rbia Moroccan river for the content of 17 elements has been performed utilizing the energy dispersive x-ray fluorescence spectrometer and total reflection excitation. SPM samples were dissolved in nitric acid. For all samples direct measurements are feasible by spiking a few ml of the sample with Ga as internal standard element, and drying an aliquot of 20 μl on a quartz glass carrier. The detection limits of 10 to 20 ppb are sufficient for most of the elements to be determined. Results were assessed for accuracy by the analysis of the 15474 ICP multi-elemental standard I. Some results were also compared with AAS and ICP-AES. The results for most of the elements obtained by TXRF were accurate to about 2-15 %. The objectives of the analysis were to determine the geo-chemical areas on this river, to explain the mechanism of sediment transport and to assess the pollution of the river by human activities. 36 samples had been collected along the river between its source in Middle Atlas and the Atlantic ocean at Azemour city. (author)

  9. Stability Analysis of Anchored Soil Slope Based on Finite Element Limit Equilibrium Method

    Directory of Open Access Journals (Sweden)

    Rui Zhang

    2016-01-01

    Full Text Available Under the condition of the plane strain, finite element limit equilibrium method is used to study some key problems of stability analysis for anchored slope. The definition of safe factor in slices method is generalized into FEM. The “true” stress field in the whole structure can be obtained by elastic-plastic finite element analysis. Then, the optimal search for the most dangerous sliding surface with Hooke-Jeeves optimized searching method is introduced. Three cases of stability analysis of natural slope, anchored slope with seepage, and excavation anchored slope are conducted. The differences in safety factor quantity, shape and location of slip surface, anchoring effect among slices method, finite element strength reduction method (SRM, and finite element limit equilibrium method are comparatively analyzed. The results show that the safety factor given by the FEM is greater and the unfavorable slip surface is deeper than that by the slice method. The finite element limit equilibrium method has high calculation accuracy, and to some extent the slice method underestimates the effect of anchor, and the effect of anchor is overrated in the SRM.

  10. Trace elements in human milk. Part of a coordinated programme on comparative methods for the study of trace elements in human nutrition

    International Nuclear Information System (INIS)

    Kosta, L.

    1981-01-01

    New analytical methods based on radiochemical neutron activation analysis were developed for the determination of Sn, V, I and Se at nanogram levels in biological materials, particularly in milk and other foodstuffs. By the application of these and similar methods, results for trace elements in human and cow's milk were collected from which the normal concentration ranges of up to 12 trace elements were established. Significant data on vanadium levels were also collected allowing assessment of the dietary intake and body pool of this element and a reappraisal of its significance in nutrition. Similar data on a smaller scale were also collected for tin. Results were also obtained for several different trace elements in a range of biological reference materials

  11. Hawaiian propolis: comparative analysis and botanical origin.

    Science.gov (United States)

    Inui, Saori; Hosoya, Takahiro; Kumazaw, Shigenori

    2014-02-01

    Propolis is a resinous mixture of substances collected and processed from various botanical sources by honeybees (Apis mellifera). We recently obtained Hawaiian propolis, the study of which, to our knowledge, has not been reported. The purpose of this study was to analyze the composition of Hawaiian propolis and to identify its botanical origin. A comparative analysis of Hawaiian and Okinawan propolis and of the glandular trichomes on Macaranga tanarius fruit (the botanical origin of Okinawan propolis) was performed using reversed-phase high-performance liquid chromatography coupled with high resolution-electrospray mass spectrometry. Hawaiian propolis contained nine prenylflavonoids that were also isolated from Okinawan propolis. In conclusion, we suggest that the botanical origin of Hawaiian propolis is M. tanarius, the same as that of Okinawan propolis.

  12. Construction QA/QC systems: comparative analysis

    International Nuclear Information System (INIS)

    Willenbrock, J.H.; Shepard, S.

    1980-01-01

    An analysis which compares the quality assurance/quality control (QA/QC) systems adopted in the highway, nuclear power plant, and U.S. Navy construction areas with the traditional quality control approach used in building construction is presented. Full participation and support by the owner as well as the contractor and AE firm are required if a QA/QC system is to succeed. Process quality control, acceptance testing and quality assurance responsibilities must be clearly defined in the contract documents. The owner must audit these responsibilities. A contractor quality control plan, indicating the tasks which will be performed and the fact that QA/QC personnel are independent of project time/cost pressures should be submitted for approval. The architect must develop realistic specifications which consider the natural variability of material. Acceptance criteria based on the random sampling technique should be used. 27 refs

  13. Comparative Genome Analysis of Basidiomycete Fungi

    Energy Technology Data Exchange (ETDEWEB)

    Riley, Robert; Salamov, Asaf; Morin, Emmanuelle; Nagy, Laszlo; Manning, Gerard; Baker, Scott; Brown, Daren; Henrissat, Bernard; Levasseur, Anthony; Hibbett, David; Martin, Francis; Grigoriev, Igor

    2012-03-19

    Fungi of the phylum Basidiomycota (basidiomycetes), make up some 37percent of the described fungi, and are important in forestry, agriculture, medicine, and bioenergy. This diverse phylum includes the mushrooms, wood rots, symbionts, and plant and animal pathogens. To better understand the diversity of phenotypes in basidiomycetes, we performed a comparative analysis of 35 basidiomycete fungi spanning the diversity of the phylum. Phylogenetic patterns of lignocellulose degrading genes suggest a continuum rather than a sharp dichotomy between the white rot and brown rot modes of wood decay. Patterns of secondary metabolic enzymes give additional insight into the broad array of phenotypes found in the basidiomycetes. We suggest that the profile of an organism in lignocellulose-targeting genes can be used to predict its nutritional mode, and predict Dacryopinax sp. as a brown rot; Botryobasidium botryosum and Jaapia argillacea as white rots.

  14. Toenail elemental analysis of Korean young adults by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Lee, O.

    2016-01-01

    The element contents in toenail clippings of healthy Korean young adults were measured using an instrumental neutron activation analysis. The average contents of elements such as Na, K, Cl, Ca, Fe, Se, and Zn are 449, 474, 1024, 1677, 66, 0.7 and 94 mg/kg in men, whereas those contents in women respectively 332, 476, 836, 1097, 66, 0.8 and 104 mg/kg. The correlation analysis of toenail elements with chronic disease risks showed positive associations between Na and serum HDL-cholesterol, blood pressure, and negative associations between Se and Hs-CRP, between Zn and hemoglobin level. (author)

  15. Multi-element analysis of emeralds and associated rocks by k0 neutron activation analysis

    International Nuclear Information System (INIS)

    Acharya, R.N.; Mondal, R.K.; Burte, P.P.; Nair, A.G.C.; Reddy, N.B.Y.; Reddy, L.K.; Reddy, A.V.R.; Manohar, S.B.

    2000-01-01

    Multi-element analysis was carried out in natural emeralds, their associated rocks and one sample of beryl obtained from Rajasthan, India. The concentrations of 21 elements were assayed by Instrumental Neutron Activation Analysis using the k 0 method (k 0 INAA method) and high-resolution gamma ray spectrometry. The data reveal the segregation of some elements from associated (trapped and host) rocks to the mineral beryl forming the gemstones. A reference rock standard of the US Geological Survey (USGS BCR-1) was also analysed as a control of the method

  16. Elemental Analysis and Radionuclides Monitoring of Beach Black Sand at North of Nile Delta, Egypt

    Science.gov (United States)

    Ali, Abdallah; Fayez-Hassan, M.; Mansour, N. A.; Mubarak, Fawzia; Ahmed, Talaat Salah; Hassanin, W. F.

    2017-12-01

    A study was carried out on the concentrations of elements presented in beach black sand samples collected from North of Nile Delta along Mediterranean Coast using instrumental neutron activation analysis (INAA) as an effective analysis technique, especially for monitoring elements. The Egyptian Research Reactor-2 (ETRR-2) as a facility was used for the samples irradiation in the thermal mode of a neutron flux 3 × 1011 n/cm2 s. Natural radioactive elements, rare element and heavy elements as U, Th, La, Lu, Sm, Ce, Nd, Eu, Gd, Sc, Tb, Yb, As, Br, Na, Sb, Ba, Co, Cr, Fe, Hg, Hf, Sr, Ta, Zn and Zr were determined with concentrations average values 16.3, 78.8, 195.4, 3.3, 31.3, 445.1, 223, 7.2, 8.5, 97.1, 3.6, 31.1, 6.1, 24.5, 27,236.8, 1.42, 1327.7, 81.1, 1814.3, 263,735, 0.1, 237.3, 878.7, 20.8, 671.1 and 6225.9 (mg/kg), respectively. The experimental data results were analyzed to evidence any correlations of these elements as well as to know the geological formation in the study area. The elements concentrations in the black sand samples were found higher than the world average crustal soil values except for As and Sb. Results were compared with similar beach black sand in previous studies. The enrichment factor (EF) and geoaccumulation index (I geo) for heavy elements were presented to evaluate the contamination rate. We can summarize that exposure for natural radionuclides (U and Th) in this area were still within the acceptable limits due to little time of exposure. Therefore, the black sands from North of Nile Delta are not recommended for use in building constructions due to high radioactive doses.

  17. Comparative Analysis of Students’ Media Competences Levels

    Directory of Open Access Journals (Sweden)

    Alexander Fedorov

    2015-08-01

    Full Text Available This article analyzed the results of survey of university students’ media literacy competence (on the base of a classification of indicators of media literacy competence of the audience as an effective tool for comparative analysis of the levels of development of media competence of students of the control and experimental groups: the level of media competence of students who have a one-year training course in the framework of media literacy education courses four times higher than in similar indicators in the control group. Analysis of the results of this survey confirmed the general trend of media contacts of student audience – its orientation to entertainment genres of audiovisual media, visually appealing; positive, active, unmarried, childless, educated, highly qualified characters (primarily – male characters aged 19 to 35 years. These heroes are characteristic optimism, independence, intelligence, emotion. They have an excellent command of the life situation and have a positive impact on the development progress of the plot of a media text.

  18. Finite element analysis of car hood for impact test by using ...

    African Journals Online (AJOL)

    Finite element analysis of car hood for impact test by using solidworks software ... high safety and at the same time can be built according to market demands. ... Keywords: finite element analysis; impact test; Solidworks; automation, car hood.

  19. Modeling hemodynamics in intracranial aneurysms: Comparing accuracy of CFD solvers based on finite element and finite volume schemes.

    Science.gov (United States)

    Botti, Lorenzo; Paliwal, Nikhil; Conti, Pierangelo; Antiga, Luca; Meng, Hui

    2018-06-01

    Image-based computational fluid dynamics (CFD) has shown potential to aid in the clinical management of intracranial aneurysms (IAs) but its adoption in the clinical practice has been missing, partially due to lack of accuracy assessment and sensitivity analysis. To numerically solve the flow-governing equations CFD solvers generally rely on two spatial discretization schemes: Finite Volume (FV) and Finite Element (FE). Since increasingly accurate numerical solutions are obtained by different means, accuracies and computational costs of FV and FE formulations cannot be compared directly. To this end, in this study we benchmark two representative CFD solvers in simulating flow in a patient-specific IA model: (1) ANSYS Fluent, a commercial FV-based solver and (2) VMTKLab multidGetto, a discontinuous Galerkin (dG) FE-based solver. The FV solver's accuracy is improved by increasing the spatial mesh resolution (134k, 1.1m, 8.6m and 68.5m tetrahedral element meshes). The dGFE solver accuracy is increased by increasing the degree of polynomials (first, second, third and fourth degree) on the base 134k tetrahedral element mesh. Solutions from best FV and dGFE approximations are used as baseline for error quantification. On average, velocity errors for second-best approximations are approximately 1cm/s for a [0,125]cm/s velocity magnitude field. Results show that high-order dGFE provide better accuracy per degree of freedom but worse accuracy per Jacobian non-zero entry as compared to FV. Cross-comparison of velocity errors demonstrates asymptotic convergence of both solvers to the same numerical solution. Nevertheless, the discrepancy between under-resolved velocity fields suggests that mesh independence is reached following different paths. This article is protected by copyright. All rights reserved.

  20. The "Critical" Elements of Illness Management and Recovery: Comparing Methodological Approaches.

    Science.gov (United States)

    McGuire, Alan B; Luther, Lauren; White, Dominique; White, Laura M; McGrew, John; Salyers, Michelle P

    2016-01-01

    This study examined three methodological approaches to defining the critical elements of Illness Management and Recovery (IMR), a curriculum-based approach to recovery. Sixty-seven IMR experts rated the criticality of 16 IMR elements on three dimensions: defining, essential, and impactful. Three elements (Recovery Orientation, Goal Setting and Follow-up, and IMR Curriculum) met all criteria for essential and defining and all but the most stringent criteria for impactful. Practitioners should consider competence in these areas as preeminent. The remaining 13 elements met varying criteria for essential and impactful. Findings suggest that criticality is a multifaceted construct, necessitating judgments about model elements across different criticality dimensions.

  1. Multi-element analysis of wheat flour and white bread by neutron activation

    International Nuclear Information System (INIS)

    Godinez A, M.A.

    1994-01-01

    One of the best source of feeding even for the human being as for animals are the Cereals. Although they are mainly energetic aliment, due to its composition in starch, they are a very important source of proteins and amino acids. They contribute mineral elements to the diet. Even those elements constitute a very small part of the total diet, they take a very important place in many human metabolic processes. To make a multielemental analysis of an aliment is very important that we are based on a very sensible analytic technique so we are able to find them, just as the Neutronic Activation. This Nuclear technique allows you to make a qualitative and quantitative analysis of the elements that are in a sample, but it does n't show the way in which the elements are presented. It is based in turning those elements into radioactive ones through its exposition to an uniform and constant fluid of neutrons, so then its radioactivity can be determined. The present work has as a main purpose to make a multielemental analysis of the wheat flour and white bread through the Neutronic Activation Technique, using the comparator method and establishing previously the most appropriate work conditions as much irradiation as digestion and measuring of the radioactivity of the sample. In this way, it was able to know that the wheat flour has potassium, chlorine, magnesium, sodium, iron, zinc, manganese, rubidium and selenium elements in a concentration of 2000, 700, 500, 25, 18, 13, 5.5, 0.9 and 0.01 - 0.3 mg/g respectively. In an other hand it was found that the white bread has the same elements than the wheat flour but its concentration was: 1700, 9000, 400, 7000, 52, 13, 6, 1 and 0.05 - 0.3 mg/g respectively. (Author)

  2. Trace element analysis of silicate rocks by XRF. Pt. 2

    International Nuclear Information System (INIS)

    Orihashi, Yuji; Yuhara, Masaki; Kagami, Hiroo; Honma, Hiroji

    1993-01-01

    Quantitative X-ray fluorescence analysis of six trace elements (Ce, Ba, Ga, Co, Cr, V) in silicate rocks has been investigated, using pressed powder pellets. Ga analysis was performed using a Cr tube, whereas a Au tube was used for the remaining five elements. Corrections were made for the interference of BaKα on CeKα, FeKβ on CoKα, CrKα on VKβ and VKα on TiKβ. Mass absorption functions were estimated from background intensities at 2θ=35.5deg and that of FeKα at wavelengths longer than the iron absorption edge for a Au tube, and from the value of net intensity/background one for a Cr tube. Calibration lines were constructed using twenty-four U.S. Geological Survey and Geological Survey of Japan igneous rock reference samples. For each line, the correction coefficient is greater than 0.993 except for Ga and Ce (>0.985), indicating that the correction and calibration procedures are appropriate for accurate analysis over a wide compositional range. Analytical results for igneous, sedimentary and metamorphic reference samples (U. S. Geological Survey, Institute of Geophysical and Geochemical Exploration, South-African Bureau of Standards) accord well with recommended or proposed values, respectively. The results of this study and those of Orihashi et al. (1993) show Ce, Ba, Nb, Zr, Y, Sr, Rb, Th, Ga, Zn, Cu, Ni, Co, Cr and V in silicate rocks can be quantitatively determined by XRF at ISEI. (author)

  3. Finite element analysis of prestressed concrete reactor vessels

    International Nuclear Information System (INIS)

    Smith, P.D.; Cook, W.A.; Anderson, C.A.

    1977-01-01

    This paper discusses the development of a finite element code suitable for the safety analysis of prestressed concrete reactor vessels. The project has involved modification of a general purpose computer code to handle reinforced concrete structures as well as comparison of results obtained with the code against published experimental data. The NONSAP nonlinear structural analysis program was selected for the ease with which it can be modified to encompass problems peculiar to nuclear reactors. Pre- and post-processors have been developed for mesh generation and for graphical display of response variables. An out-of-core assembler and solver have been developed for the analysis of large three dimensional problems. The constitutive model for short term loads forms an orthotropic stress-strain relationship in which the concrete and the reinforcing steel are treated as a composite. The variation of stiffness and strength of concrete under multiaxial stress states is accounted for. Cracks are allowed to form at element integration points based on a three dimensional failure envelope in stress space. Composite tensile and shear properties across a crack are modified to account for bond degradation and for dowel action of the reinforcement. The constitutive law for creep is base on the expansion of the usual creep compliance function in the form of a Dirichlet exponential series. Empirical creep data are then fit to the Dirichlet series approximation by means of a least squares procedure. The incremental deformation process is subsequently reduced to a series of variable stiffness elasticity problems in which the past stress history is represented by a finite number of hidden material variables

  4. Neutron activation analysis for uranium and associated elements

    International Nuclear Information System (INIS)

    Bowman, W.W.

    1977-01-01

    The samples obtained by the Savannah River Laboratory as part of the National Uranium Resource Evaluation program are activated in the intense neutron flux from a Savannah River Plant production reactor. A pilot-scale facility was installed at the reactor site to provide analyses of samples through the initial phase of the program and to develop design data for a full-scale facility. Sediments are analyzed by direct activation of 0.5-g samples. However, to analyze ground or surface water samples, mineral elements from 1-liter samples are concentrated on ion exchange resin and then approximately 5-g samples of resin are activated. Uranium concentration is determined by counting neutrons emitted from specific short-lived products of fission induced in 235 U by the primary neutron flux. Repetitive short cycles of irradiation and counting permit detection and determination of <0.1 μg of uranium. Elements associated with uranium are determined by spectral analysis of the gamma ray activities induced by the cyclic and subsequent longer irradiations. The pilot facility consists of four irradiation positions (plus 2 spare positions), a sample loader and unloader, and counting stations with neutron and gamma ray detectors, all interconnected with a pneumatic sample transport system. A computer controls both the transport system and the data acquisition devices. Gamma ray counting data are stored on magnetic tape for further processing by a large central computer. Facility hardware and software are described. Repetitive analyses of standards have shown an accuracy within +-10% for uranium values and within +-25% for associated elements. A quality assurance program has been developed to maintain these levels of reliability

  5. Storage element performance optimization for CMS analysis jobs

    International Nuclear Information System (INIS)

    Behrmann, G; Dahlblom, J; Guldmyr, J; Happonen, K; Lindén, T

    2012-01-01

    Tier-2 computing sites in the Worldwide Large Hadron Collider Computing Grid (WLCG) host CPU-resources (Compute Element, CE) and storage resources (Storage Element, SE). The vast amount of data that needs to processed from the Large Hadron Collider (LHC) experiments requires good and efficient use of the available resources. Having a good CPU efficiency for the end users analysis jobs requires that the performance of the storage system is able to scale with I/O requests from hundreds or even thousands of simultaneous jobs. In this presentation we report on the work on improving the SE performance at the Helsinki Institute of Physics (HIP) Tier-2 used for the Compact Muon Experiment (CMS) at the LHC. Statistics from CMS grid jobs are collected and stored in the CMS Dashboard for further analysis, which allows for easy performance monitoring by the sites and by the CMS collaboration. As part of the monitoring framework CMS uses the JobRobot which sends every four hours 100 analysis jobs to each site. CMS also uses the HammerCloud tool for site monitoring and stress testing and it has replaced the JobRobot. The performance of the analysis workflow submitted with JobRobot or HammerCloud can be used to track the performance due to site configuration changes, since the analysis workflow is kept the same for all sites and for months in time. The CPU efficiency of the JobRobot jobs at HIP was increased approximately by 50 % to more than 90 %, by tuning the SE and by improvements in the CMSSW and dCache software. The performance of the CMS analysis jobs improved significantly too. Similar work has been done on other CMS Tier-sites, since on average the CPU efficiency for CMSSW jobs has increased during 2011. Better monitoring of the SE allows faster detection of problems, so that the performance level can be kept high. The next storage upgrade at HIP consists of SAS disk enclosures which can be stress tested on demand with HammerCloud workflows, to make sure that the I

  6. Trace element analysis in the serum and hair of Antarctic leopard seal, Hydrurga leptonyx, and Weddell seal, Leptonychotes weddellii

    Energy Technology Data Exchange (ETDEWEB)

    Gray, Rachael [Faculty of Veterinary Science, University of Sydney, NSW 2006 Australia (Australia); Australian Marine Mammal Research Centre PO Box 20 Mosman, NSW 2088 (Australia)], E-mail: rgray@vetsci.usyd.edu.au; Canfield, Paul [Faculty of Veterinary Science, University of Sydney, NSW 2006 (Australia); Rogers, Tracey [Australian Marine Mammal Research Centre PO Box 20 Mosman, NSW 2088 (Australia); Evolution and Ecology Research Centre and School of Biological Earth and Environmental Sciences, University of New South Wales, NSW 2052 (Australia)

    2008-07-25

    Leopard seal, Hydrurga leptonyx, and Weddell seal, Leptonychotes weddellii, occupy an upper trophic level within the Antarctic ecosystem and are useful indicator species in the Southern Ocean of trace element concentrations. Reference values for the concentration of 19 trace elements were determined in the serum and hair of leopard and Weddell seals sampled in Eastern Antarctica. These reference values can be used as 'baseline' levels for monitoring trace element concentrations in these species. Greater trace element concentrations were determined in hair compared to serum, indicating different time scales of trace element accumulation in these samples. For the majority of trace elements, except for Se in the leopard seal samples and Cr in the Weddell seal samples, significant regression relationships for trace element concentrations in hair and serum were not elucidated. Significant differences were determined in the concentrations of seven out of 15 elements with hair type, moult and new, in the leopard seal; concentrations in moult hair were determined to be greater than in new hair for all elements except Zn. Hair analysis was determined to be useful for monitoring exposure to trace elements and when collected off the ice from moulting seals, hair can be employed as a non-invasive sample for trace element analysis in leopard and Weddell seals.

  7. In-situ elemental analysis of coal by neutron activation

    International Nuclear Information System (INIS)

    Mikesell, J.L.; Senftle, F.E.; Tanner, A.B.

    1986-01-01

    The U.S. Geological Survey (USGS) has worked to develop neutron techniques for the borehole measurement of the elemental composition of ores since 1969, and first demonstrated a borehole ultimate analysis of coal in 1977. Borehole measurements such as these permit real-time evaluation of coal quality without the expense of coring or the delays associated with laboratory analyses. Two technological innovations make such measurements possible: the availability, from Savannah River Operations Office, DOE, of small californium-252 (/sup 252/Cf) fission neutron sources, and the development, by USGS and Princeton Gamma-Techn, of the melting-cryogen-cooled high-purity germanium borehole gamma-ray detector. A technique of relating mass fractions to measured gamma-ray intensities, which eliminates the need for detailed knowledge of the geometry of the neutron distribution, is used to calculate elemental compositions without resorting to the test pits or computer borehole modeling. In coal, all of the major constituents (C, H, N, S, Si, Al, Fe, Ti) except oxygen can be determined quantitatively by thermal neutron capture gamma-ray spectroscopy

  8. Essential trace elements in edible mushrooms by Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Patricia L.C.; Maihara, Vera A.; Castro, Lilian P. de [Instituto de Pesquisa e Energetica e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: patricialandim@ig.com.br; vmaihara@ipen.br; lilian.Pavanelli@terra.com.br; Figueira, Rubens C.L. [Universidade Cruzeiro do Sul, Sao Paulo, SP (Brazil)]. E-mail: figueiraru@yahoo.com.br

    2007-07-01

    Mushrooms are excellent nutritional sources since they provide proteins, fibers and mineral, such as K, P, Fe. They have also been the focus of medical research. In Brazil mushrooms are not consumed in large quantities by the general population since people know little about the nutritional and medicinal benefits that mushrooms offer. Hence, this study intends to contribute to a better understanding of the essential element content in edible mushrooms, which are currently commercialized in Sao Paulo state. Br Fe, K, Na and Zn concentrations were determined by Instrumental Neutron Activation Analysis in the following mushroom species: Shitake (Lentinus edodes), Shimeji (Pleurotus ssp), Paris Champignon (Agaricus bisporus), Hiratake ( Pleurotus ssp) and Eringue (Pleurotus Eryngu. The mushroom samples were acquired from commercial establishments in the city of Sao Paulo and directly from the producers. Essential element contents in mushrooms varied between Br 0.03 to 4.1 mg/kg; Fe 20 to 267 mg/kg; K 1.2 to 5.3 g/kg, Na 10 to 582 mg/kg and Zn 60 to 120 mg/kg. The results confirm that mushrooms can be considered a good source of K, Fe and Zn. The low Na level is a good nutritional benefit for the consumer. (author)

  9. Two-Dimensional Nonlinear Finite Element Analysis of CMC Microstructures

    Science.gov (United States)

    Mital, Subodh K.; Goldberg, Robert K.; Bonacuse, Peter J.

    2012-01-01

    A research program has been developed to quantify the effects of the microstructure of a woven ceramic matrix composite and its variability on the effective properties and response of the material. In order to characterize and quantify the variations in the microstructure of a five harness satin weave, chemical vapor infiltrated (CVI) SiC/SiC composite material, specimens were serially sectioned and polished to capture images that detailed the fiber tows, matrix, and porosity. Open source quantitative image analysis tools were then used to isolate the constituents, from which two dimensional finite element models were generated which approximated the actual specimen section geometry. A simplified elastic-plastic model, wherein all stress above yield is redistributed to lower stress regions, is used to approximate the progressive damage behavior for each of the composite constituents. Finite element analyses under in-plane tensile loading were performed to examine how the variability in the local microstructure affected the macroscopic stress-strain response of the material as well as the local initiation and progression of damage. The macroscopic stress-strain response appeared to be minimally affected by the variation in local microstructure, but the locations where damage initiated and propagated appeared to be linked to specific aspects of the local microstructure.

  10. Predictive and comparative analysis of Ebolavirus proteins

    Science.gov (United States)

    Cong, Qian; Pei, Jimin; Grishin, Nick V

    2015-01-01

    Ebolavirus is the pathogen for Ebola Hemorrhagic Fever (EHF). This disease exhibits a high fatality rate and has recently reached a historically epidemic proportion in West Africa. Out of the 5 known Ebolavirus species, only Reston ebolavirus has lost human pathogenicity, while retaining the ability to cause EHF in long-tailed macaque. Significant efforts have been spent to determine the three-dimensional (3D) structures of Ebolavirus proteins, to study their interaction with host proteins, and to identify the functional motifs in these viral proteins. Here, in light of these experimental results, we apply computational analysis to predict the 3D structures and functional sites for Ebolavirus protein domains with unknown structure, including a zinc-finger domain of VP30, the RNA-dependent RNA polymerase catalytic domain and a methyltransferase domain of protein L. In addition, we compare sequences of proteins that interact with Ebolavirus proteins from RESTV-resistant primates with those from RESTV-susceptible monkeys. The host proteins that interact with GP and VP35 show an elevated level of sequence divergence between the RESTV-resistant and RESTV-susceptible species, suggesting that they may be responsible for host specificity. Meanwhile, we detect variable positions in protein sequences that are likely associated with the loss of human pathogenicity in RESTV, map them onto the 3D structures and compare their positions to known functional sites. VP35 and VP30 are significantly enriched in these potential pathogenicity determinants and the clustering of such positions on the surfaces of VP35 and GP suggests possible uncharacterized interaction sites with host proteins that contribute to the virulence of Ebolavirus. PMID:26158395

  11. Predictive and comparative analysis of Ebolavirus proteins.

    Science.gov (United States)

    Cong, Qian; Pei, Jimin; Grishin, Nick V

    2015-01-01

    Ebolavirus is the pathogen for Ebola Hemorrhagic Fever (EHF). This disease exhibits a high fatality rate and has recently reached a historically epidemic proportion in West Africa. Out of the 5 known Ebolavirus species, only Reston ebolavirus has lost human pathogenicity, while retaining the ability to cause EHF in long-tailed macaque. Significant efforts have been spent to determine the three-dimensional (3D) structures of Ebolavirus proteins, to study their interaction with host proteins, and to identify the functional motifs in these viral proteins. Here, in light of these experimental results, we apply computational analysis to predict the 3D structures and functional sites for Ebolavirus protein domains with unknown structure, including a zinc-finger domain of VP30, the RNA-dependent RNA polymerase catalytic domain and a methyltransferase domain of protein L. In addition, we compare sequences of proteins that interact with Ebolavirus proteins from RESTV-resistant primates with those from RESTV-susceptible monkeys. The host proteins that interact with GP and VP35 show an elevated level of sequence divergence between the RESTV-resistant and RESTV-susceptible species, suggesting that they may be responsible for host specificity. Meanwhile, we detect variable positions in protein sequences that are likely associated with the loss of human pathogenicity in RESTV, map them onto the 3D structures and compare their positions to known functional sites. VP35 and VP30 are significantly enriched in these potential pathogenicity determinants and the clustering of such positions on the surfaces of VP35 and GP suggests possible uncharacterized interaction sites with host proteins that contribute to the virulence of Ebolavirus.

  12. The distribution of selected inorganic elements in tobacco by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Jenkins, R.W.; Grubbs, H.J.; Newman, R.H.; Bass, R.T.; Brenizer, J.S.; Jones, D.C.; Williamson, T.G.; Danehower, D.A.; Long, R.C.

    1986-01-01

    The use of instrumental neutron activation analysis (INAA) in determining selected elements in biological materials has been reported by numerous authors. Some of these have detailed the use of INAA to determine an elemental analysis in tobaccos of various geographical origins. This paper describes the first use of INAA to measure the distribution of selected inorganic elements within the tobacco leaf at a single plant stalk position for one tobacco curing routine. Three replicate plots of a common bright tobacco cultivar were grown under normal cultural conditions characteristic for the bright variety. The tobacco leaves were sampled at selected positions in the leaf. The bright tobacco was cured in a conventional flue-curing barn using standard practices. Immediately after collection, each individual sample was freeze-dried, crushed and sampled. The leaf midrib samples were prepared using a similar procedure. A subsample of about 100 mg was taken from each sample, sealed in a polyethyelene bag, irradiated in a thermal neutron flux of 2 x 10 17 n-m -2 -s -1 in a pneumatic rabbit system, and subsequently counted to obtain the reported data. A standard reference material was used as a comparator to yield relative elemental concentrations for Ca, Mg, Mn, Na, K, Cl, and Br. The data show that chlorine, potassium, sodium and calcium have definite concentration trends within the tobacco leaf. The data also show that some elements, e,g, Mn, were more uniformly distributed throughout the leaf. (author)

  13. Finite element analysis of residual stress in plasma-sprayed ceramic

    International Nuclear Information System (INIS)

    Mullen, R.L.; Hendricks, R.C.; McDonald, G.

    1985-01-01

    Residual stress in a ZrO 2 -Y 2 O 3 ceramic coating resulting from the plasma spraying operation is calculated. The calculations were done using the finite element method. Both thermal and mechanical analysis were performed. The resulting residual stress field was compared to the measurements obtained by Hendricks and McDonald. Reasonable agreement between the predicted and measured moment occurred. However, the resulting stress field is not in pure bending

  14. Advantages and disadvantages of application of inductively coupled plasma mass spectrometry for analysis of trace elements

    International Nuclear Information System (INIS)

    Kovacs, Bela; Borbely, Maria

    2011-01-01

    In this paper the advantages and disadvantages are detailed, moreover special interference effects of the examined elements are evaluated. The detection limits of different ICP-MS instruments are compared. As a result of our research work various solutions are proposed for multielement analysis (e.g. Se, I, Co, As, Te, Cd, Pb and Cr) of the above various samples to reach more accurate and more precise results using ICP-MS instrument

  15. Active earth pressure model tests versus finite element analysis

    Science.gov (United States)

    Pietrzak, Magdalena

    2017-06-01

    The purpose of the paper is to compare failure mechanisms observed in small scale model tests on granular sample in active state, and simulated by finite element method (FEM) using Plaxis 2D software. Small scale model tests were performed on rectangular granular sample retained by a rigid wall. Deformation of the sample resulted from simple wall translation in the direction `from the soil" (active earth pressure state. Simple Coulomb-Mohr model for soil can be helpful in interpreting experimental findings in case of granular materials. It was found that the general alignment of strain localization pattern (failure mechanism) may belong to macro scale features and be dominated by a test boundary conditions rather than the nature of the granular sample.

  16. A finite-elements method for turbulent flow analysis

    International Nuclear Information System (INIS)

    Autret, A.

    1986-03-01

    The work discussed here covers turbulent flow calculations using GALERKIN's finite-element method. Turbulence effects on the mean field are taken into account by the k-epsilon model with two evolution equations: one for the kinetic energy of the turbulence, and one for the energy dissipation rate. The wall zone is covered by wall laws, and by REICHARDT's law in particular. A law is advanced for the epsilon input profile, and a numerical solution is proposed for the physically aberrant values of k and epsilon generated by the model. Single-equation models are reviewed comparatively with the k-epsilon model. A comparison between calculated and analytical solutions or calculated and experimental results is presented for decreasing turbulence behind a grid, for the flow between parallel flat plates with three REYNOLDS numbers, and for backward facing step. This part contains graphs and curves corresponding to results of the calculations presented in part one [fr

  17. A study on chemical element determinations in human nails by neutron activation analysis

    International Nuclear Information System (INIS)

    Sanches, Thalita Pinheiro; Saiki, Mitiko

    2013-01-01

    Nail analyses have been the object of study in order to assess the levels of elements accumulated in the human organism and to use this tissue to monitor environmental and occupational exposure, to evaluate the nutritional status, to verify intoxication by toxic metals and to diagnose or to prevent diseases. Nail analyses present advantages due to easy sample collection, storage, transportation and this tissue provides element level accumulation over time. However, there is controversy regarding the application of nail analysis data due to difficulties to establish reliable reference values or element concentration ranges as control values. The objective of this study was to evaluate the factors that can affect nail element concentrations for further sample analyses of a group of individuals by applying neutron activation analysis (NAA). Fingernails and toenails collected from adult individuals of both genders, aged 18 to 71 years, living in the Sao Paulo Metropolitan Region were cut in small fragments, cleaned and dried for analyses. Samples and element standards were irradiated for 16 h under a thermal neutron flux of about 4.5 x 10 12 n cm -2 s -1 at the IEA-R1 nuclear research reactor followed by gamma ray spectrometry. Element concentrations for As, Br, Ca, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Se and Zn were determined. For quality control of the analytical results, certified reference materials were analysed and the results showed good accuracy and precision with relative errors and relative standard deviations lower than 5.1 % and 11.6 %, respectively. Preliminary assays indicated that the contribution due to impurities from plastic involucres used in the irradiation as well as those from nail polishes is very low and could be considered negligible. Results from the nail sample cleaning process using distinct procedures indicated that HNO 3 solution may cause sample dissolution. Sample homogeneity was verified by analysis of a sample in replicate. A

  18. A study on chemical element determinations in human nails by neutron activation analysis

    International Nuclear Information System (INIS)

    Sanches, Thalita Pinheiro

    2012-01-01

    Nail analyses have been the object of study in order to assess the levels of elements accumulated in the human organism and to use this tissue to monitor environmental and occupational exposure, to evaluate the nutritional status, to verify intoxication by toxic metals and to diagnose or to prevent diseases. Nail analyses present advantages due to easy sample collection, storage, transportation and this tissue provides element level accumulation over time. However, there is controversy regarding the application of nail analysis data due to difficulties to establish reliable reference values or element concentration ranges as control values. The objective of this study was to evaluate the factors that can affect nail element concentrations for further sample analyses of a group of individuals by applying neutron activation analysis (NAA). Fingernails and toenails collected from adult individuals of both genders, aged 18 to 71 years, living in the Sao Paulo Metropolitan Region were cut in small fragments, cleaned and dried for analyses. Samples and element standards were irradiated for 16 h under a thermal neutron flux of about 4.5 x 10 12 n cm -2 s -1 at the IEA-R1 nuclear research reactor followed by gamma ray spectrometry. Element concentrations for As, Br, Ca, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Se and Zn were determined. For quality control of the analytical results, certified reference materials were analysed and the results showed good accuracy and precision with relative errors and relative standard deviations lower than 5.1 % and 11.6 %, respectively. Preliminary assays indicated that the contribution due to impurities from plastic involucres used in the irradiation as well as those from nail polishes is very low and could be considered negligible. Results from the nail sample cleaning process using distinct procedures indicated that HNO 3 solution may cause sample dissolution. Sample homogeneity was verified by analysis of a sample in replicate. A

  19. A study on chemical element determinations in human nails by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sanches, Thalita Pinheiro; Saiki, Mitiko, E-mail: thalitapsanches@usp.br, E-mail: mitiko@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Nail analyses have been the object of study in order to assess the levels of elements accumulated in the human organism and to use this tissue to monitor environmental and occupational exposure, to evaluate the nutritional status, to verify intoxication by toxic metals and to diagnose or to prevent diseases. Nail analyses present advantages due to easy sample collection, storage, transportation and this tissue provides element level accumulation over time. However, there is controversy regarding the application of nail analysis data due to difficulties to establish reliable reference values or element concentration ranges as control values. The objective of this study was to evaluate the factors that can affect nail element concentrations for further sample analyses of a group of individuals by applying neutron activation analysis (NAA). Fingernails and toenails collected from adult individuals of both genders, aged 18 to 71 years, living in the Sao Paulo Metropolitan Region were cut in small fragments, cleaned and dried for analyses. Samples and element standards were irradiated for 16 h under a thermal neutron flux of about 4.5 x 10{sup 12} n cm{sup -2} s{sup -1} at the IEA-R1 nuclear research reactor followed by gamma ray spectrometry. Element concentrations for As, Br, Ca, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Se and Zn were determined. For quality control of the analytical results, certified reference materials were analysed and the results showed good accuracy and precision with relative errors and relative standard deviations lower than 5.1 % and 11.6 %, respectively. Preliminary assays indicated that the contribution due to impurities from plastic involucres used in the irradiation as well as those from nail polishes is very low and could be considered negligible. Results from the nail sample cleaning process using distinct procedures indicated that HNO{sub 3} solution may cause sample dissolution. Sample homogeneity was verified by analysis of a sample in

  20. Obtaining local reciprocal lattice vectors from finite-element analysis.

    Science.gov (United States)

    Sutter, John P; Connolley, Thomas; Hill, Tim P; Huang, Houcheng; Sharp, Doug W; Drakopoulos, Michael

    2008-11-01

    Finite-element analysis is frequently used by engineers at synchrotron beamlines to calculate the elastic deformation of a single crystal undergoing mechanical bending or thermal load. ANSYS Workbench software is widely used for such simulations. However, although ANSYS Workbench software provides useful information on the displacements, strains and stresses within the crystal, it does not yield the local reciprocal lattice vectors that would be required for X-ray diffraction calculations. To bridge this gap, a method based on the shape functions and interpolation procedures of the software itself has been developed. An application to the double-crystal bent Laue monochromator being designed for the I12 (JEEP) wiggler beamline at the Diamond Light Source is presented.

  1. Elements of Constitutive Modelling and Numerical Analysis of Frictional Soils

    DEFF Research Database (Denmark)

    Jakobsen, Kim Parsberg

    of a constitutive model for soil is based on a profound knowledge of the soil behaviour upon loading. In the present study it is attempted to get a better understanding of the soil behaviour bv performing a number of triaxial compression tests on sand. The stress-strain behaviour of sand depends strongly......This thesis deals with elements of elasto-plastic constitutive modelling and numerical analysis of frictional soils. The thesis is based on a number of scientific papers and reports in which central characteristics of soil behaviour and applied numerical techniques are considered. The development...... and subsequently dilates during shear. The change in the volumetric behaviour of the soil skeleton is commonly referred to as the characteristic state. The stress ratio corresponding to the characteristic state is independent of the mean normal effective stress and the relative density, but depends on the stress...

  2. Neutron activation analysis of trace elements in biological tissue

    Energy Technology Data Exchange (ETDEWEB)

    Velandia, J A; Perkons, A K

    1974-01-01

    Thermal Neutron Activation Analysis with Instrumental Ge(Li) Gamma Spectrometry was used to determine the amounts of more than 30 trace constituents in heart tissue of rats and kidney tissue of rabbits. The results were confirmed by a rapid ion-exchange group separation method in the initial stages of the experiments. The samples were exposed to thermal neutrons for periods between 3 minutes and 14 hours. Significant differences in the amounts and types of trace elements in the two different tissue types are apparent, however, are probably due to specific diets. Tables of relevant nuclear data, standard concentrations, radiochemical separation recoveries, and quantitative analytical results are presented. The ion-exchange group separation scheme and typical examples of the instrumental gamma ray spectra are shown. The techniques developed in this study are being used for a large scale constituent survey of various diseased and healthy human tissues.

  3. Studying apple bruise using a finite element method analysis

    Science.gov (United States)

    Pascoal-Faria, P.; Alves, N.

    2017-07-01

    Apple bruise damage from harvesting, handling, transporting and sorting is considered to be the major source of reduced fruit quality, resulting in a loss of profits for the entire fruit industry. Bruising is defined as damage and discoloration of fruit flesh, usually with no breach of the skin. The three factors which can physically cause fruit bruising are vibration, compression load and impact. The last one is the main source of bruise damage. Therefore, prediction of the level of damage, stress distribution and deformation of the fruits under external force has become a very important task. To address these problems a finite element analysis has been developed for studying Portuguese Royal Gala apple bruise. The results obtained will be suitable to apple distributors and sellers and will allow a reduction of the impact caused by bruise damage in apple annual production.

  4. Instrumental Neutron Activation Analysis in archaeology interpretation beyond elemental abundance

    International Nuclear Information System (INIS)

    Bishop, Ronald L.

    2001-01-01

    Application of instrumental neutron activation analysis to the study of archaeological ceramics involves the determination of the source or sources used to produce pottery. Groups of relatively homogeneous elemental abundances are shown to be statically distinct from one another often leading to the assesment of what was locally produced and what was imported to a site. These assesment, however are among the most preliminary interpretations. Archaeology is concerned with the reasons for artificial distributions and how and why the distribution varied through time 3 reasons that include the social and political basis of ancient economics and how these responded to other factors, such as ideology. These objectives are addressed through the increasing refinement of compositional groups leading toward greater specificity of attribution. In so doing the role of analytical precision among other considerations groves in importance. This paper illustration some of these considerations with examples from the U.S. southwest, the Maya region of southern mexico, and lower central America

  5. Heterogeneous modelling and finite element analysis of the femur

    Directory of Open Access Journals (Sweden)

    Zhang Binkai

    2017-01-01

    Full Text Available As the largest and longest bone in the human body, the femur has important research value and application prospects. This paper introduces a fast reconstruction method with Mimics and ANSYS software to realize the heterogeneous modelling of the femur according to Hu distribution of the CT series, and simulates it in various situations by finite element analysis to study the mechanical characteristics of the femur. The femoral heterogeneous model shows the distribution of bone mineral density and material properties, which can be used to assess the diagnosis and treatment of bone diseases. The stress concentration position of the femur under different conditions can be calculated by the simulation, which can provide reference for the design and material selection of prosthesis.

  6. Elemental analysis of artefacts - establishing external beam PIXE

    International Nuclear Information System (INIS)

    Alves, A.; Johnston, P.; Short, R.; Bubb, I.

    1999-01-01

    The development of an external PIXE facility on the 1 MV Tandetron accelerator at RMIT has led to a wide range of research possibilities. A proton beam, generated inside a vacuum is brought into air via an Au coated Kapton foil exit window (thickness 8μm, diameter 0.35mm). Monitoring of the beam intensity is achieved by detecting backscattered protons from the inside Au coating on the window. Artefacts, which may be too large to be placed inside the vacuum, are positioned in the beamline opposite the exit window. An optical system consisting of a CCD camera, alignment laser and two mirrors allows viewing of a region of the target 10mm x 10mm. This technique provides quantitative analysis of elements in the pigments used in paintings and on ceramics, which is a valuable tool in art conservation and authentication. Application of the technique to a ceramic sample from the historic house 'Viewbank' is described

  7. Overview of adaptive finite element analysis in computational geodynamics

    Science.gov (United States)

    May, D. A.; Schellart, W. P.; Moresi, L.

    2013-10-01

    The use of numerical models to develop insight and intuition into the dynamics of the Earth over geological time scales is a firmly established practice in the geodynamics community. As our depth of understanding grows, and hand-in-hand with improvements in analytical techniques and higher resolution remote sensing of the physical structure and state of the Earth, there is a continual need to develop more efficient, accurate and reliable numerical techniques. This is necessary to ensure that we can meet the challenge of generating robust conclusions, interpretations and predictions from improved observations. In adaptive numerical methods, the desire is generally to maximise the quality of the numerical solution for a given amount of computational effort. Neither of these terms has a unique, universal definition, but typically there is a trade off between the number of unknowns we can calculate to obtain a more accurate representation of the Earth, and the resources (time and computational memory) required to compute them. In the engineering community, this topic has been extensively examined using the adaptive finite element (AFE) method. Recently, the applicability of this technique to geodynamic processes has started to be explored. In this review we report on the current status and usage of spatially adaptive finite element analysis in the field of geodynamics. The objective of this review is to provide a brief introduction to the area of spatially adaptive finite analysis, including a summary of different techniques to define spatial adaptation and of different approaches to guide the adaptive process in order to control the discretisation error inherent within the numerical solution. An overview of the current state of the art in adaptive modelling in geodynamics is provided, together with a discussion pertaining to the issues related to using adaptive analysis techniques and perspectives for future research in this area. Additionally, we also provide a

  8. Comparative analysis of safety related site characteristics

    International Nuclear Information System (INIS)

    Andersson, Johan

    2010-12-01

    This document presents a comparative analysis of site characteristics related to long-term safety for the two candidate sites for a final repository for spent nuclear fuel in Forsmark (municipality of Oesthammar) and in Laxemar (municipality of Oskarshamn) from the point of view of site selection. The analyses are based on the updated site descriptions of Forsmark /SKB 2008a/ and Laxemar /SKB 2009a/, together with associated updated repository layouts and designs /SKB 2008b and SKB 2009b/. The basis for the comparison is thus two equally and thoroughly assessed sites. However, the analyses presented here are focussed on differences between the sites rather than evaluating them in absolute terms. The document serves as a basis for the site selection, from the perspective of long-term safety, in SKB's application for a final repository. A full evaluation of safety is made for a repository at the selected site in the safety assessment SR-Site /SKB 2011/, referred to as SR-Site main report in the following

  9. Comparative analysis of safety related site characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Johan (ed.)

    2010-12-15

    This document presents a comparative analysis of site characteristics related to long-term safety for the two candidate sites for a final repository for spent nuclear fuel in Forsmark (municipality of Oesthammar) and in Laxemar (municipality of Oskarshamn) from the point of view of site selection. The analyses are based on the updated site descriptions of Forsmark /SKB 2008a/ and Laxemar /SKB 2009a/, together with associated updated repository layouts and designs /SKB 2008b and SKB 2009b/. The basis for the comparison is thus two equally and thoroughly assessed sites. However, the analyses presented here are focussed on differences between the sites rather than evaluating them in absolute terms. The document serves as a basis for the site selection, from the perspective of long-term safety, in SKB's application for a final repository. A full evaluation of safety is made for a repository at the selected site in the safety assessment SR-Site /SKB 2011/, referred to as SR-Site main report in the following

  10. Comparative analysis of franchising in international markets

    Directory of Open Access Journals (Sweden)

    Kovačević Maja

    2016-01-01

    Full Text Available The growing role of franchising at the global level requires its further improvement. This business model has great business potential, especially in the Serbian market, given the current underdevelopment and inaccessibility of information. At the core of our research, we outlined the characteristics of this business model, its impact on business development and at the same time we tried to draw the attention of domestic business entities to the benefits of franchising as a modern way of doing business. We start our research with a focus on the comparative analysis of Serbia, as a very poorly developed market. We then discuss the concept of franchising in Europe, with a special focus on Poland as a country that is ready to export franchising systems, and we continue by providing comparisons with the world's largest markets, namely, the USA and Canada. In this paper, we tried to elaborate on the economic viability of this project, as well as the increasing expansion and importance franchising has been experiencing in the last few years. Emphasis is placed on the use of franchise in many areas of business where there is the possibility of implementing both business models.

  11. Distribution of 35 Elements in Peat Cores from Ombrotrophic Bogs Studied by Epithermal Neutron Activation Analysis

    CERN Document Server

    Frontasyeva, M V

    2004-01-01

    In ombrotrophic bogs the surface peat layer is supplied with chemical substances only from the atmosphere. Peat cores from these bogs therefore can be used to study temporal trends in atmospheric deposition of pollutants. In this work epithermal neutron activation analysis was applied for the first time to study the distribution of 35 elements in peat profiles from ombrotrophic bogs. The selected examples were from Finnmark county in northern Norway: one pristine site far from any local pollution source, and another strongly affected by long-term operation of Russian copper-nickel smelters located close to the border. The elements are classified with respect to their behavior in the uppermost 40 cm of the peat, and similarities and differences between the two profiles are discussed. As compared with other more commonly used analytical techniques based on acid decomposition of the sample ENAA has the advantage of providing the total concentrations of the elements.

  12. Finite Element Analysis of Walking Beam of a New Compound Adjustment Balance Pumping Unit

    Science.gov (United States)

    Wu, Jufei; Wang, Qian; Han, Yunfei

    2017-12-01

    In this paper, taking the designer of the new compound balance pumping unit beam as our research target, the three-dimensional model is established by Solid Works, the load and the constraint are determined. ANSYS Workbench is used to analyze the tail and the whole of the beam, the stress and deformation are obtained to meet the strength requirements. The finite element simulation and theoretical calculation of the moment of the center axis beam are carried out. The finite element simulation results are compared with the calculated results of the theoretical mechanics model to verify the correctness of the theoretical calculation. Finally, the finite element analysis is consistent with the theoretical calculation results. The theoretical calculation results are preferable, and the bending moment value provides the theoretical reference for the follow-up optimization and research design.

  13. Estimation of Heavy Elements Pollution in Sea Plants (Algae) by Using Neutron Activation Analysis

    International Nuclear Information System (INIS)

    El-Ghondi, A. A.; El-Mismary, Y. A.; Etwir, R. H.; Machiouf, M. A.; Ben Shaban, Y.; Abia, R.

    2007-01-01

    The total content of trace elements were determined in 50 samples of sea plants (macro algae) collected from Tripoli coast area (Tajura, El schab, Dat Elemad ) in Libya. The samples were investigated as an indication of heavy elements pollution. In this paper, the total amounts of Zn, Sc, Fe, Co, Cr, Ba, Cs, Sb, Rb, and Hf concentration were determined by using Neutron Activation Analysis in Tajura research center. High levels of Zn and Cr and slightly increasing in amount of Co and Fe are considered as normal values comparing with polluted area particularly with Fe and Co in investigated samples. Statistical calculation of the results have shown a positive relationship between the contents of Ba, Sc, Hf, Cr and Fe-Sb but no relation with Zn and other investigated trace elements contents. Further investigation should be carried out to confirm these findings and correlate them to source attribution.

  14. Wavelet-based spectral finite element dynamic analysis for an axially moving Timoshenko beam

    Science.gov (United States)

    Mokhtari, Ali; Mirdamadi, Hamid Reza; Ghayour, Mostafa

    2017-08-01

    In this article, wavelet-based spectral finite element (WSFE) model is formulated for time domain and wave domain dynamic analysis of an axially moving Timoshenko beam subjected to axial pretension. The formulation is similar to conventional FFT-based spectral finite element (SFE) model except that Daubechies wavelet basis functions are used for temporal discretization of the governing partial differential equations into a set of ordinary differential equations. The localized nature of Daubechies wavelet basis functions helps to rule out problems of SFE model due to periodicity assumption, especially during inverse Fourier transformation and back to time domain. The high accuracy of WSFE model is then evaluated by comparing its results with those of conventional finite element and SFE results. The effects of moving beam speed and axial tensile force on vibration and wave characteristics, and static and dynamic stabilities of moving beam are investigated.

  15. Determination of rare earths and traces of other elements by neutron activation analysis

    International Nuclear Information System (INIS)

    Atalla, L.T.; Mantovani, M.S.M.; Marques, L.S.

    A complete methodology for a multielemental analysis in geological material using the neutron activation technique was developed. 21 trace elements (9 of which are rare earths) were determined using thermal and epithermal neutron irradiations. Instrumetnal and radiochemical processing, applied to BCR-1 and G-2 geological standards, are described. Statistical tests carried out on G-2 data show an error smaller than 15% referring to all elements except Cr, Sb and Yb. The observed differences between are discussed. The good precision attained in this method is confirmed by its application to BCR-1 standard, which presents errors smaller than 4% for all elements except Nd, due to its intrinsic properties. The results from the present work are compared with those from other laboratories. (C.L.B.) [pt

  16. Finite Element Analysis of the Propagation of Acoustic Waves Along Waveguides Immersed in Water

    Science.gov (United States)

    Hladky-Hennion, A.-C.; Langlet, P.; de Billy, M.

    1997-03-01

    The finite element approach has previously been used, with the help of the ATILA code, to model the propagation of acoustic waves in waveguides [A.-C. Hladky-Hennion, Journal of Sound and Vibration, 194,119-136 (1996)]. In this paper an extension of the technique to the analysis of the propagation of acoustic waves in immersed waveguides is presented. In the proposed approach, the problem is reduced to a bidimensional problem, in which only the cross-section of the guide and the surrounding fluid domain are meshed by using finite elements. Then, wedges the top angles of which vary, are studied and the finite element results of the wedge wave speed are compared with experimental results. Finally, the conclusion indicates a way to extend this approach to waveguides of any cross-section.

  17. A Signal Based Triangular Structuring Element for Mathematical Morphological Analysis and Its Application in Rolling Element Bearing Fault Diagnosis

    Directory of Open Access Journals (Sweden)

    Zhaowen Chen

    2014-01-01

    Full Text Available Mathematical morphology (MM is an efficient nonlinear signal processing tool. It can be adopted to extract fault information from bearing signal according to a structuring element (SE. Since the bearing signal features differ for every unique cause of failure, the SEs should be well tailored to extract the fault feature from a particular signal. In the following, a signal based triangular SE according to the statistics of the magnitude of a vibration signal is proposed, together with associated methodology, which processes the bearing signal by MM analysis based on proposed SE to get the morphology spectrum of a signal. A correlation analysis on morphology spectrum is then employed to obtain the final classification of bearing faults. The classification performance of the proposed method is evaluated by a set of bearing vibration signals with inner race, ball, and outer race faults, respectively. Results show that all faults can be detected clearly and correctly. Compared with a commonly used flat SE, the correlation analysis on morphology spectrum with proposed SE gives better performance at fault diagnosis of bearing, especially the identification of the location of outer race fault and the level of fault severity.

  18. A Finite Element Analysis of Optimal Variable Thickness Sheets

    DEFF Research Database (Denmark)

    Petersson, Joakim S

    1996-01-01

    A quasimixed Finite Element (FE) method for maximum stiffness of variablethickness sheets is analysed. The displacement is approximated with ninenode Lagrange quadrilateral elements and the thickness is approximated aselementwise constant. One is guaranteed that the FE displacement solutionswill ...

  19. Analysis of trace elements in chicken embryo cells

    International Nuclear Information System (INIS)

    Qiu Zhijun; Wang Jiqing; Guo Panlin; Li Xiaolin; Zhu Jieqing; Lu Rongrong

    2002-01-01

    A scanning proton microprobe (SPM) with high resolution and high sensitivity was applied to analyze trace elements in chicken embryo forebrain neutron cell and skeletal muscle myotube cell. The absorption of the two different cells to zinc ions, correlation of elements and trace elemental distributions in the cells were studied. The results indicate that the absorptive capacity of the chicken embryo forebrain neuron cell to zinc ions is larger than that of the chicken embryo skeletal muscle myotube cell, and the concentrations of intracellular trace elements such as Cr, Fe, Ni are explicitly higher. The correlations of elements such as S and Zn or Fe and Zn are positive, but the correlations of P and Ni or Cr and Fe are negative. From the maps of cellular elemental distribution the contents of the different elements are different in the intracellular parts, for example, the contents of the elements phosphorus, sulfur, potassium in the cell membranes are higher than that in the cells

  20. Finite element analysis of a crankshaft of diesel engine

    International Nuclear Information System (INIS)

    Bannikiv, M.G.

    2005-01-01

    This research was a part of the project aimed at the increase in power of the direct injection turbocharged twelve- cylinder V-type diesel engine. Crankshaft of a high power high speed diesel engine is subjected to complex loading conditions and undergoes high cyclic loads of the order of 107 to 108 cycles. Therefore, durability of this component is of critical importance. Strength analysis was based on the assessment of factor of safety (FOS) of the engine augmented by brake mean effective pressure (bmep) and/or engine speed. In the first part of the study, mechanical loads due to gas pressure and inertia forces were obtained from engine cycle simulation. Relationships for displacement, velocity and acceleration of an articulated connecting rod piston as a function of engine geometry and crank angle were derived. In the second part, the range of bmep and engine speed was determined over which engine performance is satisfactory on the basis of fatigue. It was shown that with limitations imposed (unchanged design and material of the crankshaft) the crankshaft of the given engine can withstand increase in power up to 15%. It was recommended, that required increase in engine power should be realized by the increase in bmep, since the increase in engine speed would deteriorate combustion efficiency. Finite Element Analysis was used to verify stresses calculations. New features of procedure used and relationships obtained in this research apply to strength analysis of other types of internal combustion engines. (author)

  1. Determination of trace elements in airborne particulates by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Jung, Yong Sam; Jung, Yung Joo; Jung, Eui Sik; Cho, Seung Yun

    1995-01-01

    Trace elements in airborne particulates were analyzed by instrumental neutron activation analysis(INAA) under the optimum analytical condition. Neutron irradiation for sample was done at the irradiation hole(neutron flux, 1 x 10 13 n/cm 2 s) of TRIGA MARK-III research reactor in the Korea Atomic Energy Research Institute. For the verification of the analytical method, NIST SRM-1648 and NIES CRM No.8 were chosen and analyzed. The accuracy and precision of the analysis of 40 and 24 trace elements in the samples were compared with the certified and reported values, respectively. The analytical method was found to be reliable enough when the analytical data of NIES sample were compared with those of different countries. In the analytical result of two or both of standard reference materials, relative standard deviation was within the 15% except a few elements and the relative error was within the 10%. We used this method to analyze 30 trace elements in airborne particulates collected with the high volume air sampler(PM-10) at two different locations and also confirmed the possibility to use this method as a routine monitoring tool to find out environmental pollution sources. 3 figs., 8 tabs., 19 refs. (Author)

  2. Decomposition of diverse solid inorganic matrices with molten ammonium bifluoride salt for constituent elemental analysis

    Energy Technology Data Exchange (ETDEWEB)

    O' Hara, Matthew J.; Kellogg, Cyndi M.; Parker, Cyrena M.; Morrison, Samuel S.; Corbey, Jordan F.; Grate, Jay W.

    2017-09-01

    Ammonium bifluoride (ABF, NH4F·HF) is a well-known reagent for converting metal oxides to fluorides and for its applications in breaking down minerals and ores in order to extract useful components. It has been more recently applied to the decomposition of inorganic matrices prior to elemental analysis. Herein, a sample decomposition method that employs molten ABF sample treatment in the initial step is systematically evaluated across a range of inorganic sample types: glass, quartz, zircon, soil, and pitchblende ore. Method performance is evaluated across the two variables: duration of molten ABF treatment and ABF reagent mass to sample mass ratio. The degree of solubilization of these sample classes are compared to the fluoride stoichiometry that is theoretically necessary to enact complete fluorination of the sample types. Finally, the sample decomposition method is performed on several soil and pitchblende ore standard reference materials, after which elemental constituent analysis is performed by ICP-OES and ICP-MS. Elemental recoveries are compared to the certified values; results indicate good to excellent recoveries across a range of alkaline earth, rare earth, transition metal, and actinide elements.

  3. Elemental analysis of two Egyptian iron ores and produced industrial iron samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Sroor, A.; Abdel-Basset, N.; Abdel-Haleem, A.S.; Hassan, A.M.

    2001-01-01

    Elemental analysis of two iron ores and initial industrial iron production prepared by the Egyptian Iron and Steel Company of Helwan near Cairo were performed by the instrumental neutron activation analysis technique. Five samples of each type were irradiated for 48 h in a thermal neutron flux of 4x10 12 n/cm 2 s in the first Egyptian research reactor ET-RR-1. Also, the Pneumatic Irradiation Rabbit System (PIRS), attached to the reactor ET-RR-1 in Inshass, was used to measure short-life elements. The γ-ray spectra were obtained with a hyper pure germanium detection system. The concentration percentage values of major, minor and trace elements are presented. Implications of the elemental concentration values obtained are presented

  4. Comparative Analysis of Virtual Education Applications

    Directory of Open Access Journals (Sweden)

    Mehmet KURT

    2006-10-01

    Full Text Available The research was conducted in order to make comparative analysis of virtual education applications. The research is conducted in survey model. The study group consists of total 300 institutes providing virtual education in the fall, spring and summer semesters of 2004; 246 in USA, 10 in Australia, 3 in South Africa, 10 in India, 21 in UK, 6 in Japan, 4 in Turkey. The information has been collected by online questionnaire sent to the target mass by e-mail. The questionnaire has been developed in two information categories as personal information and institutes and their virtual education applications. The English web design of the online questionnaire and the database has been prepared by Microsoft ASP codes which is the script language of Microsoft Front Page editor and has been tested on personal web site. The questionnaire has been pre applied in institutions providing virtual education in Australia. The English text of the questionnaire and web site design have been sent to educational technology and virtual education specialists in the countries of the study group. With the feedback received, the spelling mistakes have been corrected and concept and language validity have been completed. The application of the questionnaire has taken 40 weeks during March-November 2004. Only 135 institutes have replied. Two of the questionnaires have been discharged because they included mistaken coding, names of the institutions and countries. Valid 133 questionnaires cover approximately 44% of the study group. Questionnaires saved in the online database have been transferred to Microsoft Excel and then to SPSS by external database connection. In regards of the research objectives, the data collected has been analyzed on computer and by using SPSS statistics package program. In data analysis frequency (f, percentage (% and arithmetic mean ( have been used. In comparisons of country, institute, year, and other variables, che-square test, independent t

  5. Finite element analysis and validation of dielectric elastomer actuators used for active origami

    International Nuclear Information System (INIS)

    McGough, Kevin; Ahmed, Saad; Frecker, Mary; Ounaies, Zoubeida

    2014-01-01

    The field of active origami explores the incorporation of active materials into origami-inspired structures in order to serve as a means of actuation. Active origami-inspired structures capable of folding into complex three-dimensional (3D) shapes have the potential to be lightweight and versatile compared to traditional methods of actuation. This paper details the finite element analysis and experimental validation of unimorph actuators. Actuators are fabricated by adhering layers of electroded dielectric elastomer (3M VHB F9473PC) onto a passive substrate layer (3M Magic Scotch Tape). Finite element analysis of the actuators simulates the electromechanical coupling of the dielectric elastomer under an applied voltage by applying pressures to the surfaces of the dielectric elastomer where the compliant electrode (conductive carbon grease) is present. 3D finite element analysis of the bending actuators shows that applying contact boundary conditions to the electroded region of the active and passive layers provides better agreement to experimental data compared to modeling the entire actuator as continuous. To improve the applicability of dielectric elastomer-based actuators for active origami-inspired structures, folding actuators are developed by taking advantage of localized deformation caused by a passive layer with non-uniform thickness. Two-dimensional analysis of the folding actuators shows that agreement to experimental data diminishes as localized deformation increases. Limitations of using pressures to approximate the electromechanical coupling of the dielectric elastomer under an applied electric field and additional modeling considerations are also discussed. (paper)

  6. Elemental analysis of soil and hair sample by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Quraishi, Shamshad Begum; Moon, Jong Hwa; Kim, Sun Ha; Baek, Sung Yeoil; Kang, Sang Hoon; Lim, Jong Myoung; Cho, Hyun Je; Kim, Young Jin

    2004-03-01

    Myanmar soil sample was analyzed by using the instrumental neutron activation analysis. The elemental concentrations in the sample, altogether 34 elements, Al As, Ba, Ce, Co, Cr, Cs, Eu, Fe, Ga, Gd, Hf, Ir, K, La, Lu, Mn, Na, Nd, Rb, Sb, Sc, Se, Sm, Th, Ti, V, Yb, Zn and Zr were determined. The concentration of 17 elements (Al, Au, Br, Ca, Cl, Cr, Cu, Co, Fe, Hg, K, Na, Mn, Mg, Sb, Se, Zn) in human hair samples were determined by INAA For quality control of analytical method, certified reference material was used

  7. Elemental analysis of soil and hair sample by instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Yong Sam; Quraishi, Shamshad Begum; Moon, Jong Hwa; Kim, Sun Ha; Baek, Sung Yeoil; Kang, Sang Hoon; Lim, Jong Myoung; Cho, Hyun Je; Kim, Young Jin

    2004-03-01

    Myanmar soil sample was analyzed by using the instrumental neutron activation analysis. The elemental concentrations in the sample, altogether 34 elements, Al As, Ba, Ce, Co, Cr, Cs, Eu, Fe, Ga, Gd, Hf, Ir, K, La, Lu, Mn, Na, Nd, Rb, Sb, Sc, Se, Sm, Th, Ti, V, Yb, Zn and Zr were determined. The concentration of 17 elements (Al, Au, Br, Ca, Cl, Cr, Cu, Co, Fe, Hg, K, Na, Mn, Mg, Sb, Se, Zn) in human hair samples were determined by INAA For quality control of analytical method, certified reference material was used.

  8. Neutron activation analysis as applied to instrumental analysis of trace elements from seawater

    International Nuclear Information System (INIS)

    Boniforti, R.; Moauro, A.; Madaro, M.

    1983-01-01

    Particulate matter collected from the coastal area delimited by the mouth of the river Volturno and the Sabaudia lake has been analyzed by instrumental neutron activation analysis for its content of twenty-two trace elements. The results for surface water and bottom water are reported separately, thus evidencing the effect of sampling depth on the concentration of many elements. The necessity of accurately 'cleaning' the filters before use is stressed

  9. Elemental analysis of Uranouchi bay seabed sludge using PIXE

    International Nuclear Information System (INIS)

    Kabir, M. Hasnat; Narusawa, Tadashi; Nishiyama, Fumitaka; Sumi, Katsuhiro

    2006-01-01

    Elemental analyses were carried out for the seabed sludge collected from Uranouchi bay (Kochi, Japan) using Particle Induced X-ray Emission (PIXE). Seabed-sludge contamination with heavy metals as well as toxic elements becomes one of the most serious environmental problems. The aim of the present study is to investigate the polluted areas in the bay by heavy and toxic elements. As a results of analyses of samples collected from eleven different places in the bay, seventeen elements including toxic ones were detected. The results suggest that the center region of the bay is seriously contaminated by heavy and toxic elements in comparison with the other areas in the bay. (author)

  10. A comparative analysis of influenza vaccination programs.

    Directory of Open Access Journals (Sweden)

    Shweta Bansal

    2006-10-01

    Full Text Available BACKGROUND: The threat of avian influenza and the 2004-2005 influenza vaccine supply shortage in the United States have sparked a debate about optimal vaccination strategies to reduce the burden of morbidity and mortality caused by the influenza virus. METHODS AND FINDINGS: We present a comparative analysis of two classes of suggested vaccination strategies: mortality-based strategies that target high-risk populations and morbidity-based strategies that target high-prevalence populations. Applying the methods of contact network epidemiology to a model of disease transmission in a large urban population, we assume that vaccine supplies are limited and then evaluate the efficacy of these strategies across a wide range of viral transmission rates and for two different age-specific mortality distributions. We find that the optimal strategy depends critically on the viral transmission level (reproductive rate of the virus: morbidity-based strategies outperform mortality-based strategies for moderately transmissible strains, while the reverse is true for highly transmissible strains. These results hold for a range of mortality rates reported for prior influenza epidemics and pandemics. Furthermore, we show that vaccination delays and multiple introductions of disease into the community have a more detrimental impact on morbidity-based strategies than mortality-based strategies. CONCLUSIONS: If public health officials have reasonable estimates of the viral transmission rate and the frequency of new introductions into the community prior to an outbreak, then these methods can guide the design of optimal vaccination priorities. When such information is unreliable or not available, as is often the case, this study recommends mortality-based vaccination priorities.

  11. [Principal component analysis and cluster analysis of inorganic elements in sea cucumber Apostichopus japonicus].

    Science.gov (United States)

    Liu, Xiao-Fang; Xue, Chang-Hu; Wang, Yu-Ming; Li, Zhao-Jie; Xue, Yong; Xu, Jie

    2011-11-01

    The present study is to investigate the feasibility of multi-elements analysis in determination of the geographical origin of sea cucumber Apostichopus japonicus, and to make choice of the effective tracers in sea cucumber Apostichopus japonicus geographical origin assessment. The content of the elements such as Al, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Mo, Cd, Hg and Pb in sea cucumber Apostichopus japonicus samples from seven places of geographical origin were determined by means of ICP-MS. The results were used for the development of elements database. Cluster analysis(CA) and principal component analysis (PCA) were applied to differentiate the sea cucumber Apostichopus japonicus geographical origin. Three principal components which accounted for over 89% of the total variance were extracted from the standardized data. The results of Q-type cluster analysis showed that the 26 samples could be clustered reasonably into five groups, the classification results were significantly associated with the marine distribution of the sea cucumber Apostichopus japonicus samples. The CA and PCA were the effective methods for elements analysis of sea cucumber Apostichopus japonicus samples. The content of the mineral elements in sea cucumber Apostichopus japonicus samples was good chemical descriptors for differentiating their geographical origins.

  12. Finite element analysis of composite concrete-timber beams

    Directory of Open Access Journals (Sweden)

    N. C. S. FORTI

    Full Text Available AbstractIn the search for sustainable construction, timber construction is gaining in popularity around the world. Sustainably harvested wood stores carbon dioxide, while reforestation absorbs yet more CO2. One technique involves the combination of a concrete slab and a timber beam, where the two materials are assembled by the use of flexible connectors. Composite structures provide reduced costs, environmental benefits, a better acoustic performance, when compared to timber structures, and maintain structural safety. Composite structures combine materials with different mechanical properties. Their mechanical performance depends on the efficiency of the connection, which is designed to transmit shear longitudinal forces between the two materials and to prevent vertical detachment. This study contributes with the implementation of a finite element formulation for stress and displacement determination of composite concrete-timber beams. The deduced stiffness matrix and load vector are presented along to numerical examples. Numerical examples are compared to the analytical equations available in Eurocode 5 and to experimental data found in the literature.

  13. Finite element modelling and analysis of composites toecaps

    International Nuclear Information System (INIS)

    Yang, C C; Duhovic, M; Lin, R J T; Bhattacharyya, D

    2009-01-01

    Composite toe-caps have attracted considerable attention due to their advantageous properties over traditional metallic toe-caps. However, the anisotropic properties of composite materials also make the toe-cap performance more complex to analyse. This project aims at developing a Finite Element (FE) model for composite toe-caps with the aid of compression testing data. The geometry of the toe-cap was first scanned and imported into an FEA software package to create a workable FE model. The method was then validated by comparing the FE model with experimental results of steel toe-caps. Manufacturing, modelling and testing of custom-made composite toe-cap samples were then carried out. Modelling outputs of composite toe-caps were compared with compression test data for validation. The stress distributions and deformations of the toe-caps were also analysed. Modelling of the steel and composite toe-caps was realized using LS-DYNA Solver and PrePost (registered) . All FE analyses were modelled with reference to European Standards. The developed FE models can in the future be used to model toe-caps with various materials to determine the effects of fibre orientation relating to structural strength, and to achieve structural optimisation.

  14. Peace Negotiations in the Third World: A Comparative Analysis

    Directory of Open Access Journals (Sweden)

    Raúl Benítez Manaut

    1995-01-01

    Full Text Available In this article the negotiations and peace processes in the Third World are analized from a comparative viewpoint in order to focus in on the case of Centroamerica. Reference is made to the special features and common elements of those peace processes in otherregions of the Third World and they are compared to those which have taken place in Centroamerica. It is a retrospective and comparative analysis. For this reason, the author has decided to carry out a brief typology of those conflicts offered by Centroamerica: inNicaragua, El Salvador and Guatemala. Later, the author goes on to analyse the most relevant peace and negotiation processes involving the Third World including one or two from Latin America: the cases of Panama, Afghanistan, Iran-Iraq, Colombia, southern Africa (South Africa, Namibia and Angola and Cambodia. Later, the author goes overthe peace process periods in Centroamerica and the temporary contradictions which are presented by internal conflict, regional conflict and geopolitical conflict. Finally, a comparative methodological exercise is carried out which allows to focus on modes of implementation of the peace processes.

  15. Neutron activation analysis of trace elements in foodstuffs

    International Nuclear Information System (INIS)

    Schelenz, R.; Bayat, I.; Fischer, E.

    1976-05-01

    For the determination of trace elements in foodstuffs with the aid of neutron activation analysis the separation of volatile radionuclides after digestion of the sample is of special interest for radiochemical processing. A distillation procedure was developed to give reproducable results, however optimal conditions were not found for all volatile radionuclides studied. The required selective separation of Br-82 from the distillate was best achieved by the application of an ion-exchange column-chromatography technique. The computer programs for the evaluation of complex gamma spectra have been developed further. The automatic peak search and peak area determination is based on a computer program using the correlation technique and carried out with a mini-computer coupled with a multi-channel gamma spectrometer. The results, which are presented in 3 earlier reports relating to this research program, reveal the advantages and disadvantages of the individual steps of the radiochemical separation scheme. Before neutron activation analysis can be introduced on a routine basis, some aspects of the radiochemical process remain to be tested; these studies will be published in a fourth and final report. (orig.) [de

  16. Phosphogypsum analysis: total content and extractable element concentrations

    International Nuclear Information System (INIS)

    Gennari, Roseli F.; Medina, Nilberto H.; Garcia, Isabella; Silveira, Marcilei A.G.

    2011-01-01

    Phosphogypsum stand for the chemical origin gypsum generated in fertilizers production, in which phosphate rock is attacked by sulfuric acid resulting in phosphoric acid (H 3 PO 4 ) and phosphate fertilizers. Phosphogypsum is not a commercial product and it is stocked in large open areas or accumulated in lakes inducing to a major environmental problem due to the presence of toxic and radioactive elements. The increasing world agricultural demand is the real responsible for the severity of this environmental problem. Nevertheless, there are some possibilities for the application of this reject material, such as civil construction, waste water treatment, and in cultivated lands, etc. In the agriculture the phosphogypsum is commonly used as a nutrient source due to its large amounts of phosphorus, calcium and sulfur. However, there are still some environmental questions related to the use of this by-product since phosphogypsum is classified as TENORM (Technologically Enhanced Naturally Occurring Radioactive Material), which is a solid waste containing heavy metals and naturally occurring radioactive elements from the rock matrix. In this work, Plasma Mass Spectrometry (ICP-MS) was used to study phosphogypsum samples. Several acid solutions for samples digestion were evaluated in order to be feasible the chemical analysis. BCR sequential extractions were also performed. The results showed analyte concentrations are highly dependent on the acid solution used. The BCR guidelines could not be applied as used for soil, since the phosphogypsum solubility is different. So, it would be necessary to use different mass aliquots in the extractions, to be feasible an environmental evaluation. (author)

  17. Comparison of composite rotor blade models: A coupled-beam analysis and an MSC/NASTRAN finite-element model

    Science.gov (United States)

    Hodges, Robert V.; Nixon, Mark W.; Rehfield, Lawrence W.

    1987-01-01

    A methodology was developed for the structural analysis of composite rotor blades. This coupled-beam analysis is relatively simple to use compared with alternative analysis techniques. The beam analysis was developed for thin-wall single-cell rotor structures and includes the effects of elastic coupling. This paper demonstrates the effectiveness of the new composite-beam analysis method through comparison of its results with those of an established baseline analysis technique. The baseline analysis is an MSC/NASTRAN finite-element model built up from anisotropic shell elements. Deformations are compared for three linear static load cases of centrifugal force at design rotor speed, applied torque, and lift for an ideal rotor in hover. A D-spar designed to twist under axial loading is the subject of the analysis. Results indicate the coupled-beam analysis is well within engineering accuracy.

  18. Major and minor elements analysis in soil samples by neutron activation analysis and X-ray fluorescence

    International Nuclear Information System (INIS)

    Morcelli, Claudia Petronilho Ribeiro; Ana Maria Graciano; Enzweiler, Jacinta

    2002-01-01

    In the present work, Instrumental Neutron Activation Analysis (INAA) and X-Ray Fluorescence were employed to analyze major and minor elements in soil samples collected near Bandeirantes road. Elements of environmental interest, such as Al, Sb, As, Ba, Cd, Pb, Co, Cu, Cr, Fe, Mn, Mo, Ni, Se, V and Zn, which have reference background levels, were determined. The samples were dried in an oven at 40 deg C, were sieved (<2 mm), grinded and were analyzed by INAA and FRX. The aims of this work were: to evaluate the possible variations in the concentration levels in soil due to emission of particulate from vehicles and other anthropogenic sources; to compare the results obtained by using both techniques. This preliminary study showed that the concentration levels of the elements of environmental interest agree with reference values for tropical soils in the sampling sites, except for Ba, which presented higher values. (author)

  19. The Comparison Analysis of Thermalhydraulic Behavior Between A Reference 37-element Bundle and A Modified 37-element Bundle

    International Nuclear Information System (INIS)

    Ryu, Eui-Seung; You, Sung-Chang

    2014-01-01

    As pressure tube diameter creep increase, the coolant flows through some of the interior subchannels of the fuel bundle are reduced and consequently reduces the Critical Heat Flux (CHF). For this reason, Canadian Utilities have performed the project that developing the new fuel design (modified 37-element bundle) to increase critical heat flux. The modified 37-element (37M) bundle has the same overall geometry as the reference 37-element (37R) bundle that is using in the Wolsong units now but the center element diameter has been reduced from 13.06mm to 11.5mm. The reduction in center element diameter of the 37M bundle design increase the flow of center areas to improve the cooling and thus to enhance CHF. The CHF experiments with 37M bundle string simulator in un-crept and crept (3.3%, 5.1% peak creep) flow channels were completed at Stern Laboratories in 2008. A substantially large increase in dryout-power was observed for the 37M bundle compared to the 37R bundle, particularly in the 5.1% crept channel. As a result of the experiments, Ontario Power Generation (OPG) and Bruce Power (BP) have increased the operational margin with this CHF correlation and has fully refueled the 37M fuel on some units or almost done on the other units. KHNP also has performed the project to refuel the 37M bundle which is the same design with OPG and BP recently. This paper summarizes the comparison assessment of Thermalhydraulic (T/H) behavior for 37M bundle and 37R bundle with their own correlations and geometry parameters. This analysis performed with the thermal hydraulic code (NUCIRC) and the site measured data at the Wolsong Unit2. Tests to evaluate the CHF performance with the 37M fuel bundle have been conducted in 2008 using the un-crept, 3.3% crept and 5.1% crept flow channels in the CHF Test facility at Stern Laboratories. In addition pressure drop tests have been performed at the same time. The changes of geometry from 37R bundle to 37M bundle reduced the center element

  20. Investigation of faulted tunnel models by combined photoelasticity and finite element analysis

    International Nuclear Information System (INIS)

    Ladkany, S.G.; Huang, Yuping

    1994-01-01

    Models of square and circular tunnels with short faults cutting through their surfaces are investigated by photoelasticity. These models, when duplicated by finite element analysis can predict the stress states of square or circular faulted tunnels adequately. Finite element analysis, using gap elements, may be used to investigate full size faulted tunnel system